Sample records for dissection robot-assisted partial

  1. Feasibility of robot-assisted modified radical neck dissection by post-auricular facelift approach.

    PubMed

    Tae, K; Ji, Y B; Song, C M; Sung, E S; Chung, J H; Lee, S H; Park, H J

    2016-11-01

    The aim of this study was to evaluate the technical feasibility and safety of robot-assisted modified radical neck dissection (MRND) for head and neck cancer patients with a clinically node-positive neck. The cases of 10 head and neck cancer patients who underwent unilateral therapeutic robot-assisted MRND by post-auricular facelift approach were analyzed. The robot-assisted MRND was completed successfully in all patients without any conversion to conventional neck dissection. The mean number of lymph nodes removed was 36.7±8.6. The mean duration of surgery for robot-assisted MRND was 274±65min (range 175-395min). Transient marginal nerve palsy occurred in two patients and partial necrosis of the skin flap occurred in one patient. In terms of cosmetic satisfaction, 70% of patients were very satisfied or satisfied with postoperative cosmesis. In conclusion, robot-assisted MRND by post-auricular facelift approach is technically feasible and safe in selected patients with head and neck cancer, and yields excellent postoperative cosmesis. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. [Robot-assisted Pylorus-Preserving Partial Pancreaticoduodenectomy (Kausch-Whipple Procedure)].

    PubMed

    Aselmann, H; Egberts, J-H; Hinz, S; Jünemann, K-P; Becker, T

    2016-04-01

    The surgical treatment of pancreatic head tumours is one of the most complex procedures in general surgery. In contrast to colorectal surgery, minimally-invasive techniques are not very commonly applied in pancreatic surgery. Both the delicate dissection along peri- and retropancreatic vessels and the extrahepatic bile ducts and subsequent reconstruction are very demanding with rigid standard laparoscopic instruments. The 4-arm robotic surgery system with angled instruments, unidirectional movement of instruments with adjustable transmission, tremor elimination and a stable, surgeon-controlled 3D-HD view is a promising platform to overcome the limitations of standard laparoscopic surgery regarding precise dissection and reconstruction in pancreatic surgery. Pancreatic head resection for mixed-type IPMN of the pancreatic head. Robot-assisted, minimally-invasive pylorus-preserving pancreaticoduodenectomy (Kausch-Whipple procedure). The robotic approach is particularly suited for complex procedures such as pylorus-preserving pancreatic head resections. The fully robotic Kausch-Whipple procedure is technically feasible and safe. The advantages of the robotic system are apparent in the delicate dissection near vascular structures, in lymph node dissection, the precise dissection of the uncinate process and, especially, bile duct and pancreatic anastomosis. Georg Thieme Verlag KG Stuttgart · New York.

  3. Retrograde renal hilar dissection and segmental arterial clamping: a simple modification to achieve super-selective robotic partial nephrectomy.

    PubMed

    Greene, Richard N; Sutherland, Douglas E; Tausch, Timothy J; Perez, Deo S

    2014-03-01

    Super-selective vascular control prior to robotic partial nephrectomy (also known as 'zero-ischemia') is a novel surgical technique that promises to reduce warm ischemia time. The technique has been shown to be feasible but adds substantial technical complexity and cost to the procedure. We present a simplified retrograde dissection of the renal hilum to achieve selective vascular control during robotic partial nephrectomy. Consecutive patients with stage 1 solid and complex cystic renal masses underwent robotic partial nephrectomies with selective vascular control using a modification to previously described super-selective robotic partial nephrectomy. In each case, the renal arterial branch supplying the mass and surrounding parenchyma was dissected in a retrograde fashion from the tumor. Intra-renal dissection of the interlobular artery was not performed. Intra-operative immunofluorescence was not utilized as assessment of parenchymal ischemia was documented before partial nephrectomy. Data was prospectively collected in an IRB-approved partial nephrectomy database. Operative variables between patients undergoing super-selective versus standard robotic partial nephrectomy were compared. Super-selective partial nephrectomy with retrograde hilar dissection was successfully completed in five consecutive patients. There were no complications or conversions to traditional partial nephrectomy. All were diagnosed with renal cell carcinoma and surgical margins were all negative. Estimated blood loss, warm ischemia time, operative time and length of stay were all comparable between patients undergoing super-selective and standard robotic partial nephrectomy. Retrograde hilar dissection appears to be a feasible and safe approach to super-selective partial nephrectomy without adding complex renovascular surgical techniques or cost to the procedure.

  4. Preclinical study of transcervical upper mediastinal dissection for esophageal malignancy by robot-assisted surgery.

    PubMed

    Mori, Kazuhiko; Yoshimura, Shuntaro; Yamagata, Yukinori; Aikou, Susumu; Seto, Yasuyuki

    2017-06-01

    Robotic surgical systems are potentially applicable to transcervical mediastinal lymph dissection for esophageal malignancy. Robot-assisted surgery was performed on a male fresh-frozen human cadaver. Devices for single-port laparoscopic surgery were deployed via one small incision in the left clavicular area. The task for the robot-assisted surgery was the upper mediastinal dissection to the level of the left main bronchus and en bloc harvest of the lymph nodes adherent to the left recurrent laryngeal nerve. An up-angled 30° scope in the 6 o'clock port and two robotic arms from the 3 and 9 o'clock ports worked effectively together. No collisions of the devices inside the cadaveric body or unexpected traumatic events occurred. The robotic surgical system can be used safely for the upper mediastinal dissection. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Robot-assisted lobectomy for non-small cell lung cancer in china: initial experience and techniques.

    PubMed

    Zhao, Xiaojing; Qian, Liqiang; Lin, Hao; Tan, Qiang; Luo, Qingquan

    2010-03-01

    To summarize our initial experience in robot-assisted thoracoscopic lobectomy. Methods Five patients underwent lobectomy using da Vinci S HD Surgical System (Intuitive Surgical, Sunnyvale, California). During the operation, we respectively made four ports over chest wall for positioning robotic endoscope, left and right robotic arms and auxiliary instruments without retracting ribs. The procedure followed sequential anatomy as complete video-assisted thoracoscopic surgery lobectomy did, and lymph node dissection followed international standard. All patients successfully underwent complete robot-assisted thoracoscopic lobectomy. Neither additional incisions nor emergent conversion to a thoracotomy happened. Frozen dissection during lobectomy showed non-small-cell lung cancer in four patients, who afterwards underwent systemic lymph node dissection, while the case left was with tuberculoma and didn't undergo lymph node dissection. Recurrent air leak occurred in one case, so chest tube was kept for drainage, and one week later, the patient was extubated due to improvement. All other patients recovered well postoperatively without obvious postoperative complications. Robot-assisted thoracoscopic surgery is feasible with good operability, clear visual field, reliable action and its supriority of trouble free; exquisite operative skills are required to ensure a stable and safe operation; robot-assisted surgery is efficiency and patients recover well postoperatively.

  6. Robot-assisted radical cystectomy and pelvic lymph node dissection: initial experience at Roswell Park Cancer Institute.

    PubMed

    Guru, Khurshid A; Kim, Hyung L; Piacente, Pamela M; Mohler, James L

    2007-03-01

    One series of robot-assisted radical cystectomy with pelvic lymph node dissection has been reported. We report our operative technique and initial experience. Twenty consecutive patients underwent robot-assisted radical cystectomy, pelvic lymph node dissection, and open urinary diversion for operable bladder cancer from October 2005 to June 2006. Data were collected prospectively on patient demographics, intraoperative parameters, pathologic staging, and postoperative outcomes. The mean patient age was 70 years (range 56 to 90). The mean body mass index was 26 kg/m2 (range 17.3 to 36). Fourteen patients had undergone previous abdominal surgery. The mean operative time was 197 minutes for robot-assisted radical cystectomy, 44 minutes for pelvic lymph node dissection, and 133 minutes for urinary diversion. The mean blood loss was 555 mL. One case was converted to an open procedure because of the patient's inability to tolerate the Trendelenburg position. The mean hospital stay was 10 days. Two patients had major complications. One patient had positive vaginal margins and 9 of 26 nodes were positive. Four patients had incidental prostate cancer. The mean time to the return to nonstrenuous activity was 4 weeks and to strenuous activity was 10 weeks. Robot-assisted radical cystectomy and pelvic lymph node dissection can be performed safely in patients who are considered candidates for open cystectomy. Long-term oncologic control data and functional outcomes are needed to assess the true benefits of robot-assisted radical cystectomy.

  7. Karolinska prostatectomy: a robot-assisted laparoscopic radical prostatectomy technique.

    PubMed

    Nilsson, Andreas E; Carlsson, Stefan; Laven, Brett A; Wiklund, N Peter

    2006-01-01

    The last decade has witnessed an increasing trend towards minimally invasive management of prostate cancer, including laparoscopic and, more recently, robot-assisted laparoscopic prostatectomy. Several different laparoscopic approaches have been continuously developed during the last 5 years and it is still unclear which technique yields the best outcome. We present our current technique of robot-assisted laparoscopic radical prostatectomy. The technique described has evolved during the course of >400 robotic prostatectomies performed by the robotic team since the robot-assisted laparoscopic radical prostatectomy program was introduced at Karolinska University Hospital in January 2002. Our procedure comprises several modifications of previously reported ones, and we utilize fewer robotic instruments to reduce costs. An extended posterior dissection is performed to aid in the bladder neck-sparing dissection. In nerve-sparing procedures the vesicles are divided to avoid damage to the erectile nerves. In order to preserve the apical anatomy the dorsal venous complex is incised sharply and is first over-sewn after the apical dissection is completed. Our technique enables a more fluent dissection than previously described robotic techniques. Minimizing changes of instruments and the camera not only cuts costs but also reduces inefficient operating maneuvers, such as switching between 30 degrees and 0 degrees lenses during the procedure. We present a technique which in our hands has achieved excellent functional and oncological results.

  8. Functional and cosmetic outcomes of robot-assisted neck dissection by a postauricular facelift approach for head and neck cancer.

    PubMed

    Ji, Yong Bae; Song, Chang Myeon; Bang, Hyang Sook; Park, Hae Jin; Lee, Ji Young; Tae, Kyung

    2017-07-01

    The purpose of this study was to compare the functional and cosmetic outcomes of robot-assisted neck dissection with those of conventional neck dissection. We prospectively analyzed 113 patients with head and neck cancer who underwent unilateral neck dissection by a robot-assisted postauricular facelift approach (38 patients) or conventional trans-cervical approach (75 patients). Postoperative functional outcomes such as edema, sensory loss, pain, and fibrosis in the neck, and limitations of neck and shoulder motion, and cosmetic satisfaction scored by questionnaire were evaluated serially up to 1year postoperatively, and compared between the two groups. There were differences at baseline clinicopathologic characteristics including age, T classification and stage between the two groups. The mean score of neck edema was lower in the robotic group than that of the conventional group at 1day and 3days postoperatively, and sensory loss was also lower in the robotic group at 1day, 3days and 1week postoperatively (P<0.05). The postoperative cosmetic satisfaction were significantly higher in the robotic group than the conventional group at 1month, 3, 6, and 12months postoperatively. Transient marginal nerve palsy was higher in the robotic group than the conventional group (P=0.043). Postoperative neck edema and sensory loss were lower in the robotic group in the early postoperative period although its clinical significance is not clear. Cosmetic satisfaction was superior in the robotic group. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Robot-assisted partial nephrectomy: Superiority over laparoscopic partial nephrectomy.

    PubMed

    Shiroki, Ryoichi; Fukami, Naohiko; Fukaya, Kosuke; Kusaka, Mamoru; Natsume, Takahiro; Ichihara, Takashi; Toyama, Hiroshi

    2016-02-01

    Nephron-sparing surgery has been proven to positively impact the postoperative quality of life for the treatment of small renal tumors, possibly leading to functional improvements. Laparoscopic partial nephrectomy is still one of the most demanding procedures in urological surgery. Laparoscopic partial nephrectomy sometimes results in extended warm ischemic time and severe complications, such as open conversion, postoperative hemorrhage and urine leakage. Robot-assisted partial nephrectomy exploits the advantages offered by the da Vinci Surgical System to laparoscopic partial nephrectomy, equipped with 3-D vision and a better degree in the freedom of surgical instruments. The introduction of the da Vinci Surgical System made nephron-sparing surgery, specifically robot-assisted partial nephrectomy, safe with promising results, leading to the shortening of warm ischemic time and a reduction in perioperative complications. Even for complex and challenging tumors, robotic assistance is expected to provide the benefit of minimally-invasive surgery with safe and satisfactory renal function. Warm ischemic time is the modifiable factor during robot-assisted partial nephrectomy to affect postoperative kidney function. We analyzed the predictive factors for extended warm ischemic time from our robot-assisted partial nephrectomy series. The surface area of the tumor attached to the kidney parenchyma was shown to significantly affect the extended warm ischemic time during robot-assisted partial nephrectomy. In cases with tumor-attached surface area more than 15 cm(2) , we should consider switching robot-assisted partial nephrectomy to open partial nephrectomy under cold ischemia if it is imperative. In Japan, a nationwide prospective study has been carried out to show the superiority of robot-assisted partial nephrectomy to laparoscopic partial nephrectomy in improving warm ischemic time and complications. By facilitating robotic technology, robot-assisted partial nephrectomy will be more frequently carried out as a safe, effective and minimally-invasive nephron-sparing surgery procedure. © 2015 The Japanese Urological Association.

  10. Robot-assisted laparoscopic versus open partial nephrectomy in patients with chronic kidney disease: A propensity score-matched comparative analysis of surgical outcomes.

    PubMed

    Takagi, Toshio; Kondo, Tsunenori; Tachibana, Hidekazu; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Yoshida, Kazuhiko; Tanabe, Kazunari

    2017-07-01

    To compare surgical outcomes between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy in patients with chronic kidney disease. Of 550 patients who underwent partial nephrectomy between 2012 and 2015, 163 patients with T1-2 renal tumors who had an estimated glomerular filtration rate between 30 and 60 mL/min/1.73 m 2 , and underwent robot-assisted laparoscopic partial nephrectomy or open partial nephrectomy were retrospectively analyzed. To minimize selection bias between the two surgical methods, patient variables were adjusted by 1:1 propensity score matching. The present study included 75 patients undergoing robot-assisted laparoscopic partial nephrectomy and 88 undergoing open partial nephrectomy. After propensity score matching, 40 patients were included in each operative group. The mean preoperative estimated glomerular filtration rate was 49 mL/min/1.73 m 2 . The mean ischemia time was 21 min in robot-assisted laparoscopic partial nephrectomy (warm ischemia) and 35 min in open partial nephrectomy (cold ischemia). Preservation of the estimated glomerular filtration rate 3-6 months postoperatively was not significantly different between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy (92% vs 91%, P = 0.9348). Estimated blood loss was significantly lower in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (104 vs 185 mL, P = 0.0025). The postoperative length of hospital stay was shorter in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (P < 0.0001). The prevalence of Clavien-Dindo grade 3 complications and a negative surgical margin status were not significantly different between the two groups. In our experience, robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy provide similar outcomes in terms of functional preservation and perioperative complications among patients with chronic kidney disease. However, a lower estimated blood loss and shorter postoperative length of hospital stay can be obtained with robot-assisted laparoscopic partial nephrectomy. © 2017 The Japanese Urological Association.

  11. Robot-assisted laparoscopic partial nephrectomy versus laparoscopic partial nephrectomy: A propensity score-matched comparative analysis of surgical outcomes and preserved renal parenchymal volume.

    PubMed

    Tachibana, Hidekazu; Takagi, Toshio; Kondo, Tsunenori; Ishida, Hideki; Tanabe, Kazunari

    2018-04-01

    To compare surgical outcomes, including renal function and the preserved renal parenchymal volume, between robot-assisted laparoscopic partial nephrectomy and laparoscopic partial nephrectomy using propensity score-matched analyses. In total, 253 patients, with a normal contralateral kidney, who underwent laparoscopic partial nephrectomy (n = 131) or robot-assisted laparoscopic partial nephrectomy (n = 122) with renal arterial clamping between 2010 and 2015, were included. Patients' background and tumor factors were adjusted by propensity score matching. Surgical outcomes, including postoperative renal function, complications, warm ischemia time and preserved renal parenchymal volume, evaluated by volumetric analysis, were compared between the surgical procedures. After matching, 64 patients were assigned to each group. The mean age was 56-57 years, and the mean tumor size was 22 mm. Approximately 50% of patients had low complexity tumors (RENAL nephrometry score 4-7). The incidence rate of acute kidney failure was significantly lower in the robot-assisted laparoscopic partial nephrectomy (11%) than laparoscopic partial nephrectomy (23%) group (P = 0.049), and warm ischemia time shorter in the robot-assisted laparoscopic partial nephrectomy (17 min) than laparoscopic partial nephrectomy (25 min) group (P < 0.0001). The preservation rate of renal function, measured by the estimated glomerular filtration rate, at 6 months post-surgery was 96% for robot-assisted laparoscopic partial nephrectomy and 90% for laparoscopic partial nephrectomy (P < 0.0001). The preserved renal parenchymal volume was higher for robot-assisted laparoscopic partial nephrectomy (89%) than laparoscopic partial nephrectomy (77%; P < 0.0001). The rate of perioperative complications, surgical margin status and length of hospital stay were equivalent for both techniques. Robot-assisted laparoscopic partial nephrectomy allows to achieve better preservation of renal function and parenchymal volume than laparoscopic partial nephrectomy. © 2018 The Japanese Urological Association.

  12. Standardized comparison of robot-assisted limited and extended pelvic lymphadenectomy for prostate cancer.

    PubMed

    Yuh, Bertram E; Ruel, Nora H; Mejia, Rosa; Novara, Giacomo; Wilson, Timothy G

    2013-07-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Extended pelvic lymphadenectomy is the present standard of care according to European Association of Urology guidelines. Extended dissection improves staging, removes more metastatic lymph nodes, and potentially has therapeutic benefits. Previous reports have examined the morbidity of extended dissection compared with a more limited dissection in the open and laparoscopic setting. While some have suggested an increased complication rate with extended node dissection, others have not. This represents the first study focused on comparing the complications associated with the extent of node dissection using the modified Clavien system and Martin criteria in the literature on robot-assisted surgery. In a single surgeon series, we found no statistically significant differences in complications. With careful anatomic dissection, robot-assisted extended lymph node dissection can be performed safely and effectively, although operating time and length of hospital of stay are slightly increased. To compare the perioperative course of patients undergoing robot-assisted limited lymph node dissection (LLND) or extended lymph node dissection (ELND) for prostate cancer. To examine the differential lymph node counts and rates of detection of lymph node metastases. Between 2008 and 2012, 406 consecutive patients with D'Amico intermediate- or high-risk prostate cancer underwent either bilateral LLND (n = 204) or ELND (n = 202) and robot-assisted laparoscopic radical prostatectomy by a single surgeon. The region of dissection was the obturator fossa for LLND, while ELND included, in addition, the common iliac, external iliac and internal iliac lymph nodes. All complications within 90 days of surgery were recorded according to a modified Clavien system. Clinical variables were summarized and compared. Logistic regression was used to identify predictors of complications. There were no differences in demographics when comparing patients who underwent ELND with those who underwent LLND. The median operating time was 3.0 h for the ELND cohort and 2.8 h in the LLND cohort (P < 0.001). Intraoperative blood loss was 200 mL in both cohorts. Hospital stay was longer for a small percentage of patients in the ELND cohort, with 75% of ELND patients and 85% of LLND patients staying 1 day (P = 0.004). No significant difference was found in the overall or major complication rates between LLND (21.6% overall; 6.9% major) and ELND (22.8% overall; 4.5% major). No difference was seen in the symptomatic lymphocele rate between LLND and ELND, 2.9 vs 2.5%, respectively. Overall, the lymph-node-positive rate was 12% compared with 4% for the ELND and LLND groups, respectively (P = 0.002). A higher Charlson comorbidity index score was associated with the development of major complications. ELND at the time of robot-assisted radical prostatectomy can be performed safely with minimal additional morbidity. Long-term oncological and functional outcomes require further study. © 2013 BJU International.

  13. A matched comparison of perioperative outcomes of a single laparoscopic surgeon versus a multisurgeon robot-assisted cohort for partial nephrectomy.

    PubMed

    Ellison, Jonathan S; Montgomery, Jeffrey S; Wolf, J Stuart; Hafez, Khaled S; Miller, David C; Weizer, Alon Z

    2012-07-01

    Minimally invasive nephron sparing surgery is gaining popularity for small renal masses. Few groups have evaluated robot-assisted partial nephrectomy compared to other approaches using comparable patient populations. We present a matched pair analysis of a heterogeneous group of surgeons who performed robot-assisted partial nephrectomy and a single experienced laparoscopic surgeon who performed conventional laparoscopic partial nephrectomy. Perioperative outcomes and complications were compared. All 249 conventional laparoscopic and robot-assisted partial nephrectomy cases from January 2007 to June 2010 were reviewed from our prospectively maintained institutional database. Groups were matched 1:1 (108 matched pairs) by R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines) nephrometry score, transperitoneal vs retroperitoneal approach, patient age and hilar nature of the tumor. Statistical analysis was done to compare operative outcomes and complications. Matched analysis revealed that nephrometry score, age, gender, tumor side and American Society of Anesthesia physical status classification were similar. Operative time favored conventional laparoscopic partial nephrectomy. During the study period robot-assisted partial nephrectomy showed significant improvements in estimated blood loss and warm ischemia time compared to those of the experienced conventional laparoscopic group. Postoperative complication rates, and complication distributions by Clavien classification and type were similar for conventional laparoscopic and robot-assisted partial nephrectomy (41.7% and 35.0%, respectively). Robot-assisted partial nephrectomy has a noticeable but rapid learning curve. After it is overcome the robotic procedure results in perioperative outcomes similar to those achieved with conventional laparoscopic partial nephrectomy done by an experienced surgeon. Robot-assisted partial nephrectomy likely improves surgeon and patient accessibility to minimally invasive nephron sparing surgery. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Commentary on "a matched comparison of perioperative outcomes of a single laparoscopic surgeon versus a multisurgeon robot-assisted cohort for partial nephrectomy." Ellison JS, Montgomery JS, Wolf Jr JS, Hafez KS, Miller DC, Weizer AZ, Department of Urology, University of Michigan, Ann Arbor, MI, USA: J Urol 2012;188(1):45-50.

    PubMed

    Kane, Christopher

    2013-02-01

    Minimally invasive nephron sparing surgery is gaining popularity for small renal masses. Few groups have evaluated robot-assisted partial nephrectomy compared to other approaches using comparable patient populations. We present a matched pair analysis of a heterogeneous group of surgeons who performed robot-assisted partial nephrectomy and a single experienced laparoscopic surgeon who performed conventional laparoscopic partial nephrectomy. Perioperative outcomes and complications were compared. All 249 conventional laparoscopic and robot-assisted partial nephrectomy cases from January 2007 to June 2010 were reviewed from our prospectively maintained institutional database. Groups were matched 1:1 (108 matched pairs) by R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines) nephrometry score, transperitoneal vs retroperitoneal approach, patient age and hilar nature of the tumor. Statistical analysis was done to compare operative outcomes and complications. Matched analysis revealed that nephrometry score, age, gender, tumor side and American Society of Anesthesia physical status classification were similar. Operative time favored conventional laparoscopic partial nephrectomy. During the study period robot-assisted partial nephrectomy showed significant improvements in estimated blood loss and warm ischemia time compared to those of the experienced conventional laparoscopic group. Postoperative complication rates, and complication distributions by Clavien classification and type were similar for conventional laparoscopic and robot-assisted partial nephrectomy (41.7% and 35.0%, respectively). Robot-assisted partial nephrectomy has a noticeable but rapid learning curve. After it is overcome the robotic procedure results in perioperative outcomes similar to those achieved with conventional laparoscopic partial nephrectomy done by an experienced surgeon. Robot-assisted partial nephrectomy likely improves surgeon and patient accessibility to minimally invasive nephron sparing surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Robot-assisted thoracoscopic lymphadenectomy along the left recurrent laryngeal nerve for esophageal squamous cell carcinoma in the prone position: technical report and short-term outcomes.

    PubMed

    Suda, Koichi; Ishida, Yoshinori; Kawamura, Yuichiro; Inaba, Kazuki; Kanaya, Seiichiro; Teramukai, Satoshi; Satoh, Seiji; Uyama, Ichiro

    2012-07-01

    Meticulous mediastinal lymphadenectomy frequently induces recurrent laryngeal nerve palsy (RLNP). Surgical robots with impressive dexterity and precise dissection skills have been developed to help surgeons perform operations. The objective of this study was to determine the impact on short-term outcomes of robot-assisted thoracoscopic radical esophagectomy performed on patients in the prone position for the treatment of esophageal squamous cell carcinoma, including its impact on RLNP. A single-institution nonrandomized prospective study was performed. The patients (n = 36) with resectable esophageal squamous cell carcinoma were divided into two groups: patients who agreed to robot-assisted thoracoscopic esophagectomy with total mediastinal lymphadenectomy performed in the prone position (n = 16, robot-assisted group) without insurance reimbursement, and those who agreed to undergo the same operation without robot assistance but with health insurance coverage (n = 20, control group). These patients were observed for 30 days following surgery to assess short-term surgical outcomes, including the incidence of vocal cord palsy, hoarseness, and aspiration. Robot assistance significantly reduced the incidence of vocal cord palsy (p = 0.018) and hoarseness (p = 0.015) and the time on the ventilator (p = 0.025). There was no in-hospital mortality in either group. There were no significant differences between the two groups with respect to patient background, except for the use of preoperative therapy (robot-assisted group

  16. Robotic selective neck dissection using a gasless postauricular facelift approach for early head and neck cancer: technical feasibility and safety.

    PubMed

    Tae, Kyung; Ji, Yong Bae; Song, Chang Myeon; Min, Hyun Jung; Kim, Kyung Rae; Park, Chul Won

    2013-03-01

    Abstract Background: Scarless and minimally invasive surgery is becoming popular in the head and neck area. We have developed a new robotic selective neck dissection procedure for head and neck squamous cell carcinoma (HNSCC) to avoid a long visible lateral neck scar. Here we report on the technical feasibility and safety of our procedure. We prospectively analyzed 4 patients with early HNSCC who underwent transoral robotic surgery (TORS) and concomitant robotic selective neck dissection via a gasless postauricular facelift approach using the da Vinci(®) Surgical System (Intuitive Surgical Inc., Sunnyvale, CA). Of these patients, 3 were male, and 1 was female. The mean age was 59.0±8.8 years. All patients had tongue cancer, with a clinically negative neck. Three patients were T1, and 1 patient was T2. All patients underwent partial glossectomy by TORS and elective robotic selective neck dissection including levels I, II, and III. The robotic selective neck dissection procedure was completed successfully in all patients. The mean operative time was 276±48 minutes. The mean number of lymph nodes removed was 19.3±7.3. Postoperative hematoma and transient marginal nerve palsy occurred in 1 patient each. Cosmetic satisfaction was excellent in all patients. Preliminary results indicate that robotic selective neck dissection via a gasless postauricular facelift approach is feasible and safe and allows for excellent postoperative cosmesis. Further studies are necessary to determine the oncologic safety and surgical completeness of this procedure compared with conventional neck dissection.

  17. Two-year analysis for predicting renal function and contralateral hypertrophy after robot-assisted partial nephrectomy: A three-dimensional segmentation technology study.

    PubMed

    Kim, Dae Keun; Jang, Yujin; Lee, Jaeseon; Hong, Helen; Kim, Ki Hong; Shin, Tae Young; Jung, Dae Chul; Choi, Young Deuk; Rha, Koon Ho

    2015-12-01

    To analyze long-term changes in both kidneys, and to predict renal function and contralateral hypertrophy after robot-assisted partial nephrectomy. A total of 62 patients underwent robot-assisted partial nephrectomy, and renal parenchymal volume was calculated using three-dimensional semi-automatic segmentation technology. Patients were evaluated within 1 month preoperatively, and postoperatively at 6 months, 1 year and continued up to 2-year follow up. Linear regression models were used to identify the factors predicting variables that correlated with estimated glomerular filtration rate changes and contralateral hypertrophy 2 years after robot-assisted partial nephrectomy. The median global estimated glomerular filtration rate changes were -10.4%, -11.9%, and -2.4% at 6 months, 1 and 2 years post-robot-assisted partial nephrectomy, respectively. The ipsilateral kidney median parenchymal volume changes were -24%, -24.4%, and -21% at 6 months, 1 and 2 years post-robot-assisted partial nephrectomy, respectively. The contralateral renal volume changes were 2.3%, 9.6% and 12.9%, respectively. On multivariable linear analysis, preoperative estimated glomerular filtration rate was the best predictive factor for global estimated glomerular filtration rate change on 2 years post-robot-assisted partial nephrectomy (B -0.452; 95% confidence interval -0.84 to -0.14; P = 0.021), whereas the parenchymal volume loss rate (B -0.43; 95% confidence interval -0.89 to -0.15; P = 0.017) and tumor size (B 5.154; 95% confidence interval -0.11 to 9.98; P = 0.041) were the significant predictive factors for the degree of contralateral renal hypertrophy on 2 years post-robot-assisted partial nephrectomy. Preoperative estimated glomerular filtration rate significantly affects post-robot-assisted partial nephrectomy renal function. Renal mass size and renal parenchyma volume loss correlates with compensatory hypertrophy of the contralateral kidney. Contralateral hypertrophy of the renal parenchyma compensates for the functional loss of the ipsilateral kidney. © 2015 The Japanese Urological Association.

  18. Unilateral robotic hybrid mini-maze: a novel experimental approach.

    PubMed

    Moslemi, Mohammad; Rawashdeh, Badi; Meyer, Mark; Nguyen, Duy; Poston, Robert; Gharagozloo, Farid

    2016-03-01

    A complete Cox maze IV procedure is difficult to accomplish using current endoscopic and minimally invasive techniques. These techniques are hampered by inability to adequately dissect the posterior structures of the heart and place all necessary lesions. We present a novel approach, using robotic technology, that achieves placement of all the lesions of the complete maze procedure. In three cadaveric human models, the technical feasibility of using robotic instruments through the right chest to dissect the posterior structures of the heart and place all Cox maze lesions was performed. The entire posterior aspect of the heart was dissected in the cadaveric model facilitating successful placement of all Cox maze IV lesions with robotic assistance through minimally invasive incisions. The robotic Cox maze IV procedure through the novel right thoracic approach is feasible. This obviates the need for sternotomy and avoids the associated morbidity of the conventional Cox-maze procedure. Copyright © 2015 John Wiley & Sons, Ltd.

  19. The University of Pennsylvania curriculum for training otorhinolaryngology residents in transoral robotic surgery.

    PubMed

    Sperry, Steven M; O'Malley, Bert W; Weinstein, Gregory S

    2014-01-01

    To define a curriculum for the development of robotic surgical skills in otorhinolaryngology residency training. A systematic review of the current literature on robotic surgery training was performed. Based on prior reports in other specialties, a curriculum for otorhinolaryngology residents was created that progresses through several modules, including didactics, inanimate skills laboratory, and operative experience. The curriculum for residents in otorhinolaryngology was designed as follows: didactics include an overview of the robotic device and instruments, a tutorial in basic controls and function, and a room setup and positioning. The anatomy and steps of transoral procedures are taught through books, videos, operative observations, and cadaver dissections. Skills are developed with a virtual reality robotic simulator and robotics labs. The operative experience progresses from case observation to bedside assistant to console surgeon. The role of the console surgeon progresses in a stepwise fashion, and the procedures of radical tonsillectomy, supraglottic partial laryngectomy, and base of tongue resection have been organized as a series of steps. A structured curriculum for training residents in transoral robotic surgery was developed. This training is important for otorhinolaryngology residents to acquire the knowledge and skills to perform robotic surgery safely. © 2015 S. Karger AG, Basel.

  20. The da Vinci robotic surgical assisted anterior lumbar interbody fusion: technical development and case report.

    PubMed

    Beutler, William J; Peppelman, Walter C; DiMarco, Luciano A

    2013-02-15

    Technique development to use the da Vince Robotic Surgical System for anterior lumbar interbody fusion at L5-S1 is detailed. A case report is also presented. To evaluate and develop the da Vinci robotic assisted laparoscopic anterior lumbar stand-alone interbody fusion procedure. Anterior lumbar interbody fusion is a common procedure associated with potential morbidity related to the surgical approach. The da Vinci robot provides intra-abdominal dissection and visualization advantages compared with the traditional open and laparoscopic approach. The surgical techniques for approach to the anterior lumbar spine using the da Vinci robot were developed and modified progressively beginning with operative models followed by placement of an interbody fusion cage in the living porcine model. Development continued to progress with placement of fusion cage in a human cadaver, completed first in the laboratory setting and then in the operating room. Finally, the first patient with fusion completed using the da Vinci robot-assisted approach is presented. The anterior transperitoneal approach to the lumbar spine is accomplished with enhanced visualization and dissection capability, with maintenance of pneumoperitoneum using the da Vinci robot. Blood loss is minimal. The visualization inside the disc space and surrounding structures was considered better than current open and laparoscopic techniques. The da Vinci robot Surgical System technique continues to develop and is now described for the transperitoneal approach to the anterior lumbar spine. 4.

  1. Use of the Endoholder device during robotic-assisted laparoscopic radical prostatectomy: the "poor man's" fourth arm equivalent.

    PubMed

    Zorn, Kevin C; Gofrit, Ofer N; Zagaja, Gregory P; Shalhav, Arieh L

    2008-02-01

    During standard, six-port set-up, robotic-assisted laparoscopic radical prostatectomy (RLRP) using a three-arm daVinci system (DVS), two assistants are routinely required. The role of the second assistant is often limited to isometric traction during prostate dissection. Due to muscle fatigue and inability of the operator to see the operative field, frequent repositioning of the second assistant is often required. In an attempt to improve efficiency in such surgical situations, we describe the use of the Endoholder, an adjustable articulating instrument holder, to assist during RLRP. During 100 consecutive cases, the Endoholder provided quick, reproducible retraction to facilitate exposure. No complications occurred with its use. The device reduced the need for a dedicated second assistant to stand bedside. We have achieved significant improvements in the safety and efficiency of retraction of the rectum, bladder, and prostate during RLRP with the Endoholder. For urologists working with a three-armed DVS, use of the Endoholder may help facilitate tissue retraction during dissection.

  2. Crowdsourcing Assessment of Surgeon Dissection of Renal Artery and Vein During Robotic Partial Nephrectomy: A Novel Approach for Quantitative Assessment of Surgical Performance.

    PubMed

    Powers, Mary K; Boonjindasup, Aaron; Pinsky, Michael; Dorsey, Philip; Maddox, Michael; Su, Li-Ming; Gettman, Matthew; Sundaram, Chandru P; Castle, Erik P; Lee, Jason Y; Lee, Benjamin R

    2016-04-01

    We sought to describe a methodology of crowdsourcing for obtaining quantitative performance ratings of surgeons performing renal artery and vein dissection of robotic partial nephrectomy (RPN). We sought to compare assessment of technical performance obtained from the crowdsourcers with that of surgical content experts (CE). Our hypothesis is that the crowd can score performances of renal hilar dissection comparably to surgical CE using the Global Evaluative Assessment of Robotic Skills (GEARS). A group of resident and attending robotic surgeons submitted a total of 14 video clips of RPN during hilar dissection. These videos were rated by both crowd and CE for technical skills performance using GEARS. A minimum of 3 CE and 30 Amazon Mechanical Turk crowdworkers evaluated each video with the GEARS scale. Within 13 days, we received ratings of all videos from all CE, and within 11.5 hours, we received 548 GEARS ratings from crowdworkers. Even though CE were exposed to a training module, internal consistency across videos of CE GEARS ratings remained low (ICC = 0.38). Despite this, we found that crowdworker GEARS ratings of videos were highly correlated with CE ratings at both the video level (R = 0.82, p < 0.001) and surgeon level (R = 0.84, p < 0.001). Similarly, crowdworker ratings of the renal artery dissection were highly correlated with expert assessments (R = 0.83, p < 0.001) for the unique surgery-specific assessment question. We conclude that crowdsourced assessment of qualitative performance ratings may be an alternative and/or adjunct to surgical experts' ratings and would provide a rapid scalable solution to triage technical skills.

  3. Combined Partial Penectomy With Bilateral Robotic Inguinal Lymphadenectomy Using Near-infrared Fluorescence Guidance.

    PubMed

    Sávio, Luís Felipe; Panizzutti Barboza, Marcelo; Alameddine, Mahmoud; Ahdoot, Michael; Alonzo, David; Ritch, Chad R

    2018-03-01

    To describe our novel technique for performing a combined partial penectomy and bilateral robotic inguinal lymphadenectomy using intraoperative near-infrared (NIR) fluorescence guidance with indocyanine green (ICG) and the DaVinci Firefly camera system. A 58-year-old man presented status post recent excisional biopsy of a 2-cm lesion on the left coronal aspect of the glans penis. Pathology revealed "invasive squamous cell carcinoma of the penis with multifocal positive margins." His examination was suspicious for cT2 primary and his inguinal nodes were cN0. He was counseled to undergo partial penectomy with possible combined vs staged bilateral robotic inguinal lymphadenectomy. Preoperative computed tomography scan was negative for pathologic lymphadenopathy. Before incision, 5 mL of ICG was injected subcutaneously beneath the tumor. Bilateral thigh pockets were then developed simultaneously and a right, then left robotic modified inguinal lymphadenectomy was performed using NIR fluorescence guidance via the DaVinci Firefly camera. A partial penectomy was then performed in the standard fashion. The combined procedure was performed successfully without complication. Total operative time was 379 minutes and total robotic console time was 95 minutes for the right and 58 minutes to the left. Estimated blood loss on the right and left were 15 and 25 mL, respectively. A total of 24 lymph nodes were retrieved. This video demonstrates a safe and feasible approach for combined partial penectomy and bilateral inguinal lymphadenectomy with NIR guidance using ICG and the DaVinci Firefly camera system. The combined robotic approach has minimal morbidity and avoids the need for a staged procedure. Furthermore, use of NIR guidance with ICG during robotic inguinal lymphadenectomy is feasible and may help identify sentinel lymph nodes and improve the quality of dissection. Further studies are needed to confirm the utility of NIR guidance for robotic sentinel lymph node dissection. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A comparative cost analysis of robot-assisted versus traditional laparoscopic partial nephrectomy.

    PubMed

    Hyams, Elias; Pierorazio, Philip; Mullins, Jeffrey K; Ward, Maryann; Allaf, Mohamad

    2012-07-01

    Robot-assisted laparoscopic partial nephrectomy (RALPN) is supplanting traditional laparoscopic partial nephrectomy (LPN) as the technique of choice for minimally invasive nephron-sparing surgery. This evolution has resulted from potential clinical benefits, as well as proliferation of robotic systems and patient demand for robot-assisted surgery. We sought to quantify the costs associated with the use of robotics for minimally invasive partial nephrectomy. A cost analysis was performed for 20 consecutive robot-assisted partial nephrectomy (RPN) and LPN patients at our institution from 2009 to 2010. Data included actual perioperative and hospitalization costs as well as professional fees. Capital costs were estimated using purchase costs and amortization of two robotic systems from 2001 to 2009, as well as maintenance contract costs. The estimated cost/case was obtained using total robotic surgical volume during this period. Total estimated costs were compared between groups. A separate analysis was performed assuming "ideal" robotic utilization during a comparable period. RALPN had a cost premium of +$1066/case compared with LPN, assuming actual robot utilization from 2001 to 2009. Assuming "ideal" utilization during a comparable period, this premium decreased to +$334; capital costs per case decreased from $1907 to $1175. Tumor size, operative time, and length of stay were comparable between groups. RALPN is associated with a small to moderate cost premium depending on assumptions regarding robotic surgical volume. Saturated utilization of robotic systems decreases attributable capital costs and makes comparison with laparoscopy more favorable. Purported clinical benefits of RPN (eg, decreased warm ischemia time, increased utilization of nephron-sparing surgery) need further study, because these may have cost implications.

  5. Robot-assisted partial cystectomy of a bladder pheochromocytoma.

    PubMed

    Kang, Sung Gu; Kang, Seok Ho; Choi, Hoon; Ko, Young Hwii; Park, Hong Seok; Cheon, Jun

    2011-01-01

    Pheochromocytoma of the urinary bladder is an unusual tumor that typically presents with hypertensive crises related to micturition. We report here an unusual case of bladder pheochromocytoma that was treated by robotic-assisted laparoscopic partial cystectomy. A 35-year-old male patient presented with headache and hypertension related to micturition. The patient, who had a 3.5 × 4 cm solitary bladder tumor in the bladder dome, underwent robot-assisted partial cystectomy. The whole procedure was successfully performed using the robot without conversion to open surgery. The total operative time was 120 min and the estimated blood loss was 30 ml. Copyright © 2011 S. Karger AG, Basel.

  6. Erectile Function and Oncologic Outcomes Following Open Retropubic and Robot-assisted Radical Prostatectomy: Results from the LAParoscopic Prostatectomy Robot Open Trial.

    PubMed

    Sooriakumaran, Prasanna; Pini, Giovannalberto; Nyberg, Tommy; Derogar, Maryam; Carlsson, Stefan; Stranne, Johan; Bjartell, Anders; Hugosson, Jonas; Steineck, Gunnar; Wiklund, Peter N

    2018-04-01

    Whether surgeons perform better utilising a robot-assisted laparoscopic technique compared with an open approach during prostate cancer surgery is debatable. To report erectile function and early oncologic outcomes for both surgical modalities, stratified by prostate cancer risk grouping. In a prospective nonrandomised trial, we recruited 2545 men with prostate cancer from seven open (n=753) and seven robot-assisted (n=1792) Swedish centres (2008-2011). Clinometrically-validated questionnaire-based patient-reported erectile function was collected before, 3 mo, 12 mo, and 24 mo after surgery. Surgeon-reported degree of neurovascular-bundle preservation, pathologist-reported positive surgical margin (PSM) rates, and 2-yr prostate-specific antigen-relapse rates were measured. Among 1702 preoperatively potent men, we found enhanced erectile function recovery for low/intermediate-risk patients in the robot-assisted group at 3 mo. For patients with high-risk tumours, point estimates for erectile function recovery at 24 mo favoured the open surgery group. The degree of neurovascular bundle preservation and erectile function recovery were greater correlated for robot-assisted surgery. In pT2 tumours, 10% versus 17% PSM rates were observed for open and robot-assisted surgery, respectively; corresponding rates for pT3 tumours were 48% and 33%. These differences were associated with biochemical recurrence in pT3 but not pT2 disease. The study is limited by its nonrandomised design and relatively short follow-up. Earlier recovery of erectile function in the robot-assisted surgery group in lower-risk patients is counterbalanced by lower PSM rates for open surgeons in organ-confined disease; thus, both open and robotic surgeons need to consider this trade-off when determining the plane of surgical dissection. Robot-assisted surgery also facilitates easier identification of nerve preservation planes during radical prostatectomy as well as wider dissection for pT3 cases. For prostate cancer surgery, an open operation reduces erection problems in high-risk cancers but has higher relapse rates than robotic surgery. Relapse rates appear similar in low/intermediate-risk cancers and the robot appears better at preserving erections in these cases. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  7. Robotic-assisted laparoscopic partial nephrectomy: initial experience in Brazil and a review of the literature.

    PubMed

    Passerotti, Carlo Camargo; Pessoa, Rodrigo; da Cruz, Jose Arnaldo Shiomi; Okano, Marcelo Takeo; Antunes, Alberto Azoubel; Nesrallah, Adriano Joao; Dall'oglio, Marcos Francisco; Andrade, Enrico; Srougi, Miguel

    2012-01-01

    Partial nephrectomy has become the standard of care for renal tumors less than 4 cm in diameter. Controversy still exists, however, regarding the best surgical approach, especially when minimally invasive techniques are taken into account. Robotic-assisted laparoscopic partial nephrectomy (RALPN) has emerged as a promising technique that helps surgeons achieve the standards of open partial nephrectomy care while offering a minimally invasive approach. The objective of the present study was to describe our initial experience with robotic-assisted laparoscopic partial nephrectomy and extensively review the pertinent literature. Between August 2009 and February 2010, eight consecutive selected patients with contrast enhancing renal masses observed by CT were submitted to RALPN in a private institution. In addition, we collected information on the patients ' demographics, preoperative tumor characteristics and detailed operative, postoperative and pathological data. In addition, a PubMed search was performed to provide an extensive review of the robotic-assisted laparoscopic partial nephrectomy literature. Seven patients had RALPN on the left or right sides with no intraoperative complications. One patient was electively converted to a robotic-assisted radical nephrectomy. The operative time ranged from 120 to 300 min, estimated blood loss (EBL) ranged from 75 to 400 mL and, in five cases, the warm ischemia time (WIT) ranged from 18 to 32 min. Two patients did not require any clamping. Overall, no transfusions were necessary, and there were no intraoperative complications or adverse postoperative clinical events. All margins were negative, and all patients were disease-free at the 6-month follow-up. Robotic-assisted laparoscopic partial nephrectomy is a feasible and safe approach to small renal cortical masses. Further prospective studies are needed to compare open partial nephrectomy with its minimally invasive counterparts.

  8. [Cost comparison of open and robot-assisted partial nephrectomy in treatment of renal tumor].

    PubMed

    Abd El Fattah, V; Chevrot, A; Meusy, A; Mercier, G; Wagner, L; Soustelle, L; Boukaram, M; Thuret, R; Costa, P; Droupy, S

    2016-04-01

    Robot-assisted partial nephrectomy rapidly took on among urologists, even though studies showing its superiority over other techniques are still scarce and its costs hard to evaluate, especially in the French medical system. To evaluate the cost overrun of robot-assisted partial nephrectomy compared to that of open partial nephrectomy. From January 2010 to December 2013, 77 patients underwent a partial nephrectomy, 46 of which by robot-assisted laparoscopy and the remaining 31 by lombotomy. The two groups were similar in composition. Economic data regarding the staff, the consumables and the premises involved have been analyzed. Costs are significantly higher in the NPR group (9253.21 euros vs. 7448.42 euros) due to higher consumable expenses as well as the costs pertaining to the amortization and maintenance of the robot. Yet, that difference tends to diminish as the duration of the experiment increases. No significant difference was found in warm ischemia times, operation duration and renal function a month after the operation. On the other hand, patients from the NPR group spent a significantly smaller amount of time in recovery room (159 minutes vs. 205 minutes, P=0.004), presented fewer complications and were discharged faster (6.1 days vs. 8.1 days, P=0.04). To be profitable for the hospital in the French GHS system, robot-assisted partial nephrectomy must take place in a complex where at least 300 robot-assisted interventions are performed annually, in the framework of a hospitalization lasting four days or less, the use of a single needle holder and no systematic use of a haemostatic agent. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Transoral robotic supraglottic partial laryngectomy.

    PubMed

    Kayhan, Fatma Tülin; Kaya, Kamil Hakan; Altintas, Ahmet; Sayin, Ibrahim

    2014-07-01

    Transoral robotic supraglottic laryngectomy is a new surgical way to perform endolaryngeal resection of supraglottic laryngeal carcinoma. The aim of this report was to present our initial experience about transoral robotic supraglottic laryngectomy for early supraglottic cancer. Subjects with early squamous cell carcinoma (T1-T2) of supraglottic region who managed using transoral robotic surgery in a tertiary referral center were included in the study. The technique of robot-assisted resection, intraoperative blood loss, mean robotic operating time, pathologic margin status, postoperative extubation, need for a tracheotomy, and length of hospitalization, complications, duration of oral nutrition, and neck dissection and radiotherapy needs were evaluated. Thirteen subjects (12 men, 1 woman) with T1-T2 supraglottic carcinoma were successfully operated on with transoral robotic surgery. In all subjects, negative margins were obtained. The mean total robotic surgery time was 31.6 (SD, 16.2) minutes (range, 20-80 minutes). Mean total blood loss was less than 40 mL. Subjects started oral nutrition with a mean of 10.8 (SD, 8.9) days (range, 4-30 days) postoperatively. The mean hospitalization was 15.4 (SD, 10.4) days (range, 7-42 days). Transoral robotic supraglottic laryngectomy with the da Vinci robotic system can be regarded as a feasible, safe, and effective technique. Although short-term results seem discouraging, long-term results are needed to evaluate the oncologic safety.

  10. The efficacy and utilisation of preoperative multiparametric magnetic resonance imaging in robot-assisted radical prostatectomy: does it change the surgical dissection plan?

    PubMed

    Tavukçu, Hasan Hüseyin; Aytaç, Ömer; Balcı, Numan Cem; Kulaksızoğlu, Haluk; Atuğ, Fatih

    2017-12-01

    We investigated the effect of the use of multiparametric prostate magnetic resonance imaging (mp-MRI) on the dissection plan of the neurovascular bundle and the oncological results of our patients who underwent robot-assisted radical prostatectomy. We prospectively evaluated 60 consecutive patients, including 30 patients who had (Group 1), and 30 patients who had not (Group 2) mp-MRI before robot-assisted radical prostatectomy. Based on the findings of mp-MRI, the dissection plan was changed as intrafascial, interfascial, and extrafascial in the mp-MRI group. Two groups were compared in terms of age, prostate-specific antigen (PSA), Gleason sum scores and surgical margin positivity. There was no statistically significant difference between the two groups in terms of age, PSA, biopsy Gleason score, final pathological Gleason score and surgical margin positivity. mp-MRI changed the initial surgical plan in 18 of 30 patients (60%) in Group 1. In seventeen of these patients (56%) surgical plan was changed from non-nerve sparing to interfascial nerve sparing plan. In one patient dissection plan was changed to non-nerve sparing technique which had extraprostatic extension on final pathology. Surgical margin positivity was similar in Groups 1, and 2 (16% and 13%, respectively) although, Group 1 had higher number of high- risk patients. mp-MRI confirmed the primary tumour localisation in the final pathology in 27 of of 30 patients (90%). Preoperative mp-MRI effected the decision to perform a nerve-sparing technique in 56% of the patients in our study; moreover, changing the dissection plan from non-nerve-sparing technique to a nerve sparing technique did not increase the rate of surgical margin positivity.

  11. Robotic Telesurgery Research

    DTIC Science & Technology

    2010-10-01

    Miniature In Vivo Robotic System for the Surgical Treatment of Diverticular Disease Source of Support: National Institute of Health (NIH) Total...completion time   • Suturing   • Gastrotomy   • Partial colon resection   • Completion of a fully closed procedure - the robot was inserted...repositioned over the sigmoid colon in the left pelvis of the swine and was used, with one grasper hand and one cautery hand, to dissect out the mesentery of

  12. Use of near infrared fluorescence during robot-assisted laparoscopic partial nephrectomy.

    PubMed

    Cornejo-Dávila, V; Nazmy, M; Kella, N; Palmeros-Rodríguez, M A; Morales-Montor, J G; Pacheco-Gahbler, C

    2016-04-01

    Partial nephrectomy is the treatment of choice for T1a tumours. The open approach is still the standard method. Robot-assisted laparoscopic surgery offers advantages that are applicable to partial nephrectomy, such as the use of the Firefly® system with near-infrared fluorescence. To demonstrate the implementation of fluorescence in nephron-sparing surgery. This case concerned a 37-year-old female smoker, with obesity. The patient had a right kidney tumour measuring 31 mm, which was found using tomography. She therefore underwent robot-assisted laparoscopic partial nephrectomy, with a warm ischaemia time of 22 minutes and the use of fluorescence with the Firefly® system to guide the resection. There were no complications. The tumour was a pT1aN0M0 renal cell carcinoma, with negative margins. Robot-assisted renal laparoscopic surgery is employed for nephron-sparing surgery, with good oncological and functional results. The combination of the Firefly® technology and intraoperative ultrasound can more accurately delimit the extent of the lesion, increase the negative margins and decrease the ischaemia time. Near-infrared fluorescence in robot-assisted partial nephrectomy is useful for guiding the tumour resection and can potentially improve the oncological and functional results. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Effect of Regional Hospital Competition and Hospital Financial Status on the Use of Robotic-Assisted Surgery.

    PubMed

    Wright, Jason D; Tergas, Ana I; Hou, June Y; Burke, William M; Chen, Ling; Hu, Jim C; Neugut, Alfred I; Ananth, Cande V; Hershman, Dawn L

    2016-07-01

    Despite the lack of efficacy data, robotic-assisted surgery has diffused rapidly into practice. Marketing to physicians, hospitals, and patients has been widespread, but how this marketing has contributed to the diffusion of the technology remains unknown. To examine the effect of regional hospital competition and hospital financial status on the use of robotic-assisted surgery for 5 commonly performed procedures. A cohort study of 221 637 patients who underwent radical prostatectomy, total nephrectomy, partial nephrectomy, hysterectomy, or oophorectomy at 1370 hospitals in the United States from January 1, 2010, to December 31, 2011, was conducted. The association between hospital competition, hospital financial status, and performance of robotic-assisted surgery was examined. The association between hospital competition was measured with the Herfindahl-Hirschman Index (HHI), hospital financial status was estimated as operating margin, and performance of robotic-assisted surgery was examined using multivariate mixed-effects regression models. We identified 221 637 patients who underwent one of the procedures of interest. The cohort included 30 345 patients who underwent radical prostatectomy; 20 802, total nephrectomy; 8060, partial nephrectomy; 134 985, hysterectomy; and 27 445, oophorectomy. Robotic-assisted operations were performed for 20 500 (67.6%) radical prostatectomies, 1405 (6.8%) total nephrectomies, 2759 (34.2%) partial nephrectomies, 14 047 (10.4%) hysterectomies, and 1782 (6.5%) oophorectomies. Use of robotic-assisted surgery increased for each procedure from January 2010 through December 2011. For all 5 operations, increased market competition (as measured by the HHI) was associated with increased use of robotic-assisted surgery. For prostatectomy, the risk ratios (95% CIs) for undergoing a robotic-assisted procedure were 2.20 (1.50-3.24) at hospitals in moderately competitive markets and 2.64 (1.84-3.78) for highly competitive markets compared with noncompetitive markets. For hysterectomy, patients at hospitals in moderately (3.75 [2.26-6.25]) and highly (5.30; [3.27-8.57]) competitive markets were more likely to undergo a robotic-assisted surgery. Increased hospital profitability was associated with use of robotic-assisted surgery only for partial nephrectomy in facilities with medium-high (1.67 [1.13-2.48]) and high (1.50 [0.98-2.29]) operating margins. With analysis limited to patients treated at a hospital that had performed robotic-assisted surgery, there was no longer an association between competition and use of robotic-assisted surgery. Patients undergoing surgery in a hospital in a competitive regional market were more likely to undergo a robotic-assisted procedure. These data imply that regional competition may influence a hospital's decision to acquire a surgical robot.

  14. Review of robot-assisted partial nephrectomy in modern practice

    PubMed Central

    Weaver, John; Benway, Brian M.

    2015-01-01

    Partial nephrectomy (PN) is currently the standard treatment for T1 renal tumors. Minimally invasive PN offers decreased blood loss, shorter length of stay, rapid convalescence, and improved cosmesis. Due to the challenges inherent in laparoscopic partial nephrectomy, its dissemination has been stifled. Robot-assisted partial nephrectomy (RAPN) offers an intuitive platform to perform minimally invasive PN. It is one of the fastest growing robotic procedures among all surgical subspecialties. RAPN continues to improve upon the oncological and functional outcomes of renal tumor extirpative therapy. Herein, we describe the surgical technique, outcomes, and complications of RAPN. PMID:28326257

  15. Use of robotics in colon and rectal surgery.

    PubMed

    Pucci, Michael J; Beekley, Alec C

    2013-03-01

    The pace of innovation in the field of surgery continues to accelerate. As new technologies are developed in combination with industry and clinicians, specialized patient care improves. In the field of colon and rectal surgery, robotic systems offer clinicians many alternative ways to care for patients. From having the ability to round remotely to improved visualization and dissection in the operating room, robotic assistance can greatly benefit clinical outcomes. Although the field of robotics in surgery is still in its infancy, many groups are actively investigating technologies that will assist clinicians in caring for their patients. As these technologies evolve, surgeons will continue to find new and innovative ways to utilize the systems for improved patient care and comfort.

  16. Value of Robotically Assisted Surgery for Mitral Valve Disease

    PubMed Central

    Mihaljevic, Tomislav; Koprivanac, Marijan; Kelava, Marta; Goodman, Avi; Jarrett, Craig; Williams, Sarah J.; Gillinov, A. Marc; Bajwa, Gurjyot; Mick, Stephanie L.; Bonatti, Johannes; Blackstone, Eugene H.

    2014-01-01

    Importance The value of robotically assisted surgery for mitral valve disease is questioned because the high cost of care associated with robotic technology may outweigh its clinical benefits. Objective To investigate conditions under which benefits of robotic surgery mitigate high technology costs. Design Clinical cohort study comparing costs of robotic vs. three contemporaneous conventional surgical approaches for degenerative mitral disease. Surgery was performed from 2006–2011, and comparisons were based on intent-to-treat, with propensity-matching used to reduce selection bias. Setting Large multi-specialty academic medical center. Participants 1,290 patients aged 57±11 years, 27% women, underwent mitral repair for regurgitation from posterior leaflet prolapse. Robotic surgery was used in 473, complete sternotomy in 227, partial sternotomy in 349, and anterolateral thoracotomy in 241. Three propensity-matched groups were formed based on demographics, symptoms, cardiac and noncardiac comorbidities, valve pathophysiology, and echocardiographic measurements: robotic vs. sternotomy (n=198 pairs) vs. partial sternotomy (n=293 pairs) vs. thoracotomy (n=224 pairs). Interventions Mitral valve repair. Main Outcome Measures Cost of care, expressed as robotic capital investment, maintenance, and direct technical hospital cost, and benefit of care, based on differences in recovery time. Results Median cost of care for robotically assisted surgery exceeded the cost of alternative approaches by 27% (−5%, 68%), 32% (−6%, 70%), and 21% (−2%, 54%) (median [15th, 85th percentiles]) for complete sternotomy, partial sternotomy, and anterolateral thoracotomy, respectively. Higher operative costs were partially offset by lower postoperative costs and earlier return to work: median 35 days for robotic surgery, 49 for complete sternotomy, 56 for partial sternotomy, and 42 for anterolateral thoracotomy. Resulting net differences in cost of robotic surgery vs. the three alternatives were 16% (−15%, 55%), 16% (−19%, 51%), and 15% (−7%, 49%), respectively. Beyond a volume threshold of 55–100 robotic cases per year, confidence limits for the cost of robotic surgery broadly overlapped those of conventional approaches. Conclusions In exchange for higher procedural costs, robotically assisted mitral valve surgery offers the clinical benefit of least invasive surgery, lowest postoperative cost, and fastest return to work. The value of robotically assisted surgery comparable to conventional approaches can only be realized in high-volume centers. PMID:24848944

  17. Robotic-Assisted Videothoracoscopic Surgery of the Lung.

    PubMed

    Velez-Cubian, Frank O; Ng, Emily P; Fontaine, Jacques P; Toloza, Eric M

    2015-07-01

    Despite initial concerns about the general safety of videothoracoscopic surgery, minimally invasive videothoracoscopic surgical procedures have advantages over traditional open thoracic surgery via thoracotomy. Robotic-assisted minimally invasive surgery has expanded to almost every surgical specialty, including thoracic surgery. Adding a robotic-assisted surgical system to a videothoracoscopic surgical procedure corrects several shortcomings of videothoracoscopic surgical cameras and instruments. We performed a literature search on robotic-assisted pulmonary resections and compared the published robotic series data with our experience at the H. Lee Moffitt Cancer Center & Research Institute. All perioperative outcomes, such as intraoperative data, postoperative complications, chest tube duration, hospital length of stay (LOS), and in-hospital mortality rates were noted. Our literature search found 23 series from multiple surgical centers. We divided the literature into 2 groups based on the year published (2005-2010 and 2011-2014). Operative times from earlier studies ranged from 150 to 240 minutes compared with 90 to 242 minutes for later studies. Conversion rates (to open lung resection) from the earlier studies ranged from 0% to 19% compared with 0% to 11% in the later studies. Mortality rates for the earlier studies ranged from 0% to 5% compared with 0% to 2% for the later studies. Since 2010, our group has performed more than 600 robotic-assisted thoracic surgical procedures, including more than 200 robotic-assisted pulmonary lobectomies, which we also divided into 2 groups. Our median skin-to-skin operative time improved from 179 minutes for our early group (n = 104) to 172 minutes for our later group (n = 104). The overall conversion rate was 9.6% and the emergent conversion rate (for bleeding) was 5% for our robotic-assisted lobectomies. The most common postoperative complications in our cohort were prolonged air leak (> 7 days; 16.8%) and atrial fibrillation (12%). Hospital LOS for the early series ranged from 3 to 11 days compared with 2 to 6 days for the later series. Median hospital LOS decreased from 6 to 4 days. Our mortality rate was 1.4%; 3 in-hospital deaths occurred in the early 40 cases. Mediastinal lymph node (LN) dissection and detection of occult mediastinal LN metastases were improved during robotic-assisted lobectomy for non-small-cell lung cancer, as demonstrated by an overall 30% upstaging rate, including a 19% nodal upstaging rate, in our cohort. Robotic-assisted videothoracoscopic pulmonary lobectomy appears to be as safe as conventional videothoracoscopic surgical lobectomy, which has decreased perioperative complications and a shorter hospital LOS than open lobectomy. Both mediastinal LN dissection and the early detection of occult mediastinal LN metastatic disease were improved by robotic-assisted videothoracoscopic surgical compared with conventional videothoracoscopic surgical or open thoracotomy.

  18. First year experience of robotic-assisted laparoscopic surgery with 153 cases in a general surgery department: indications, technique and results.

    PubMed

    Tomulescu, V; Stănciulea, O; Bălescu, I; Vasile, S; Tudor, St; Gheorghe, C; Vasilescu, C; Popescu, I

    2009-01-01

    Robotic surgery was developed in response to the limitations and drawbacks of laparoscopic surgery. Since 1997 when the first robotic procedure was performed various papers pointed the advantages of robotic-assisted laparoscopic surgery, this technique is now a reality and it will probably become the surgery of the future. The aim of this paper is to present our preliminary experience with the three-arms "da Vinci S surgical system", to assess the feasibility of this technique in various abdominal and thoracic procedures and to point out the advantages of the robotic approach for each type of procedure. Between 18 January 2008 and 18 January 2009 153 patients (66 men and 87 women; mean age 48,02 years, range 6 to 84 years) underwent robotic-assisted surgical procedures in our institution; we performed 129 abdominal and 24 thoracic procedures, as follows: one cholecystectomy, 14 myotomies with Dor fundoplication, one gastroenteroanastomosis for unresectable antral gastric cancer, one transthoracic esophagectomy, 14 gastrectomies, one polypectomy through gastrotomy, 22 splenectomies,7 partial spleen resections, 22 thymectomy, 6 Nissen fundoplications, one Toupet fundoplication, one choledocho-duodeno-anastomosis, one drainage for pancreatic abscess, one distal pancreatectomy, one hepatic cyst fenestration, 7 hepatic resections, 29 colonic and rectal resections, 5 adrenalectomies, 12 total radical hysterectomies and pelvic lymphadenectomy, 3 hysterectomies with bilateral adnexectomy for uterine fibroma, one unilateral adnexectomy, and 2 cases of cervico-mediastinal goitre resection. 147 procedures were robotics completed , whereas 6 procedures were converted to open surgery due to the extent of the lesion. Average operating room time was 171 minutes (range 60 to 600 minutes, Median length of stay was 8,6 days (range 2 to 48 days). One system malfunctions was registered. Post-operatory complications occurred in 14 cases. There were no deaths. Our preliminary experience suggests that robotic surgery is feasible and worth of clinical application. The best indications for robotic surgery are the procedures that require a small operating field, a fine a precise dissection (suitable for pelvic and gastric lymphadenectomy, nerve sparing in total mesorectal excision) and safe intracorporeal sutures.

  19. Renal functional and perioperative outcomes of off-clamp versus clamped robot-assisted partial nephrectomy: matched cohort study.

    PubMed

    Tanagho, Youssef S; Bhayani, Sam B; Sandhu, Gurdarshan S; Vaughn, Nicholas P; Nepple, Kenneth G; Figenshau, R Sherburne

    2012-10-01

    To evaluate the potential benefit of performing off-clamp robot-assisted partial nephrectomy as it relates to renal functional outcomes, while assessing the safety profile of this unconventional surgical approach. Twenty-nine patients who underwent off-clamp robot-assisted partial nephrectomy for suspected renal cell carcinoma at Washington University between March 2008 and September 2011 (group 1) were matched to 29 patients with identical nephrometry scores and comparable baseline renal function who underwent robot-assisted partial nephrectomy with hilar clamping during the same period (group 2). The matched cohorts' perioperative and renal functional outcomes were compared at a mean 9-month follow-up. Mean estimated blood loss was 146.4 mL in group 1, versus 103.9 mL in group 2 (P = .039). Mean hilar clamp time was 0 minutes in group 1 and 14.7 minutes in group 2. No perioperative complications were encountered in group 1; 1 Clavien-2 complication (3.4%) occurred in group 2 (P = 1.000). At 9-month follow-up, mean estimated glomerular filtration rate in group 1 was 79.9 versus 84.8 mL/min/1.73 m(2) preoperatively (P = .013); mean estimated glomerular filtration rate in group 2 was 74.1 versus 85.8 mL/min/1.73 m(2) preoperatively (P < .001). Hence, estimated glomerular filtration rate declined by a mean of 4.9 mL/min/1.73 m(2) in group 1 versus 11.7 mL/min/1.73 m(2) in group 2 (P = .033). Off-clamp robot-assisted partial nephrectomy is associated with a favorable morbidity profile and relatively greater renal functional preservation compared to clamped robot-assisted partial nephrectomy. Nevertheless, the benefit is small in renal functional terms and may have very limited clinical relevance. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Use of Robotics in Colon and Rectal Surgery

    PubMed Central

    Pucci, Michael J.; Beekley, Alec C.

    2013-01-01

    The pace of innovation in the field of surgery continues to accelerate. As new technologies are developed in combination with industry and clinicians, specialized patient care improves. In the field of colon and rectal surgery, robotic systems offer clinicians many alternative ways to care for patients. From having the ability to round remotely to improved visualization and dissection in the operating room, robotic assistance can greatly benefit clinical outcomes. Although the field of robotics in surgery is still in its infancy, many groups are actively investigating technologies that will assist clinicians in caring for their patients. As these technologies evolve, surgeons will continue to find new and innovative ways to utilize the systems for improved patient care and comfort. PMID:24436647

  1. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    PubMed

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  2. [Robotic splenectomy--a personal view].

    PubMed

    Vasilescu, C

    2010-01-01

    Until now 40 robotic splenectomies were performed in our department, the first case being done on February 25, 2008. Our data show that robotic splenectomy with the DaVinci surgical system is technically feasible and safe, with good results and without complications. The main advantages are a better tridimensional view and an increased versatility of the surgical instruments. The DaVinci system allows an accurate dissection around the splenic hilum and preservation of the splenic remnant vessels in partial splenectomy. Robotic splenectomy will probably not replace the laparoscopic splenectomy for the most common indications like ITP, hemolytic anemia. It may be a very useful surgical tool in difficult splenectomy: partial splenectomy, splenectomy in liver cirrhosis, splenic tumors or malignant hemopathies. In these cases the robotic approach may shorten the operative time, decrease the blood loss and the risk of remorrhagic complications during surgery and even make possible a minimally invasive splenectomy very difficult to be performed by classical laparoscopy.

  3. Advanced Applications of Robotics in Digestive Surgery

    PubMed Central

    Patriti, Alberto; Addeo, Pietro; Buchs, Nicolas; Casciola, Luciano; Morel, Philippe

    2011-01-01

    Laparoscopy is widely recognized as feasible and safe approach to many oncologic and benign digestive conditions and is associated with an improved early outcome. Robotic surgery promises to overcome intrinsic limitations of laparoscopic surgery by a three-dimensional view and wristed instruments widening indications for a minimally invasive approach. To date, the more interesting applications of robotic surgery are those operations restricted to one abdominal quadrant and requiring a fine dissection and digestive reconstruction. While robot-assisted rectal and gastric surgery are becoming well-accepted options among the surgical community, applications of robotics in hepato-biliary and pancreatic surgery are still debated. PMID:23905029

  4. Robotic anatomic segmentectomy of the lung: technical aspects and initial results.

    PubMed

    Pardolesi, Alessandro; Park, Bernard; Petrella, Francesco; Borri, Alessandro; Gasparri, Roberto; Veronesi, Giulia

    2012-09-01

    Robotic lobectomy with radical lymph node dissection is a new frontier of minimally invasive thoracic surgery. Series of sublobar anatomic resection for primary initial lung cancers or for metastasis using video-assisted thoracic surgery have been reported but no cases have been so far reported using the robot-assisted approach. We present the technique and surgical outcome of our initial experience. Clinical data of patients undergoing robotic lung anatomic segmentectomy were retrospectively reviewed. All cases were done using the DaVinci System. A 3- or 4-incision strategy with a 3-cm utility incision in the anterior fourth or fifth intercostal space was performed. Individual ligation and division of the hilar structures was performed using Hem-o-Lok (Teleflex Medical, Research Triangle Park, NC) or endoscopic staplers. The parenchyma was transected with endovascular staplers introduced by the bedside assistant mainly through the utility incision. Systematic mediastinal lymph node dissection or sampling was performed. From 2008 to 2010, 17 patients underwent a robot-assisted lung anatomic segmentectomy in two centers. There were 10 women and 7 men with a mean age of 68.2 years (range, 32 to 82). Mean duration of surgery was 189 minutes. There were no major intraoperative complications. Conversion to open procedure was never required. Postoperative morbidity rate was 17.6% with pneumonia in 1 case and prolonged air leaks in 2 patients. Median postoperative stay was 5 days (range, 2 to 14), and postoperative mortality was 0%. Final pathology was non-small cell lung cancer in 8 patient, typical carcinoids in 2, and lung metastases in 7. Robotic anatomic lung segmentectomy is feasible and safe procedure. Robotic system, by improving ergonomic, surgeon view and precise movements, may make minimally invasive segmentectomy easier to adopt and perform. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Laparoscopic and robot-assisted gastrectomy for gastric cancer: Current considerations

    PubMed Central

    Caruso, Stefano; Patriti, Alberto; Roviello, Franco; De Franco, Lorenzo; Franceschini, Franco; Coratti, Andrea; Ceccarelli, Graziano

    2016-01-01

    Radical gastrectomy with an adequate lymphadenectomy is the main procedure which makes it possible to cure patients with resectable gastric cancer (GC). A number of randomized controlled trials and meta-analysis provide phase III evidence that laparoscopic gastrectomy is technically safe and that it yields better short-term outcomes than conventional open gastrectomy for early-stage GC. While laparoscopic gastrectomy has become standard therapy for early-stage GC, especially in Asian countries such as Japan and South Korea, the use of minimally invasive techniques is still controversial for the treatment of more advanced tumours, principally due to existing concerns about its oncological adequacy and capacity to carry out an adequately extended lymphadenectomy. Some intrinsic drawbacks of the conventional laparoscopic technique have prevented the worldwide spread of laparoscopic gastrectomy for cancer and, despite technological advances in recent year, it remains a technically challenging procedure. The introduction of robotic surgery over the last ten years has implied a notable mutation of certain minimally invasive procedures, making it possible to overcome some limitations of the traditional laparoscopic technique. Robot-assisted gastric resection with D2 lymph node dissection has been shown to be safe and feasible in prospective and retrospective studies. However, to date there are no high quality comparative studies investigating the advantages of a robotic approach to GC over traditional laparoscopic and open gastrectomy. On the basis of the literature review here presented, robot-assisted surgery seems to fulfill oncologic criteria for D2 dissection and has a comparable oncologic outcome to traditional laparoscopic and open procedure. Robot-assisted gastrectomy was associated with the trend toward a shorter hospital stay with a comparable morbidity of conventional laparoscopic and open gastrectomy, but randomized clinical trials and longer follow-ups are needed to evaluate the possible influence of robot gastrectomy on GC patient survival. PMID:27433084

  6. Surgery Videos: MedlinePlus

    MedlinePlus Videos and Cool Tools

    ... 2009) Mitral Valve Prolapse Minimally Invasive Heart Surgery: Robot Assisted Mitral Valve Repair (Baptist Health South Florida, ... Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission Medical ...

  7. Navigating the pathway to robotic competency in general thoracic surgery.

    PubMed

    Seder, Christopher W; Cassivi, Stephen D; Wigle, Dennis A

    2013-01-01

    Although robotic technology has addressed many of the limitations of traditional videoscopic surgery, robotic surgery has not gained widespread acceptance in the general thoracic community. We report our initial robotic surgery experience and propose a structured, competency-based pathway for the development of robotic skills. Between December 2008 and February 2012, a total of 79 robot-assisted pulmonary, mediastinal, benign esophageal, or diaphragmatic procedures were performed. Data on patient characteristics and perioperative outcomes were retrospectively collected and analyzed. During the study period, one surgeon and three residents participated in a triphasic, competency-based pathway designed to teach robotic skills. The pathway consisted of individual preclinical learning followed by mentored preclinical exercises and progressive clinical responsibility. The robot-assisted procedures performed included lung resection (n = 38), mediastinal mass resection (n = 19), hiatal or paraesophageal hernia repair (n = 12), and Heller myotomy (n = 7), among others (n = 3). There were no perioperative mortalities, with a 20% complication rate and a 3% readmission rate. Conversion to a thoracoscopic or open approach was required in eight pulmonary resections to facilitate dissection (six) or to control hemorrhage (two). Fewer major perioperative complications were observed in the later half of the experience. All residents who participated in the thoracic surgery robotic pathway perform robot-assisted procedures as part of their clinical practice. Robot-assisted thoracic surgery can be safely learned when skill acquisition is guided by a structured, competency-based pathway.

  8. Usefulness of robot-assisted thoracoscopic esophagectomy.

    PubMed

    Osaka, Yoshiaki; Tachibana, Shingo; Ota, Yoshihiro; Suda, Takeshi; Makuuti, Yosuke; Watanabe, Takafumi; Iwasaki, Kenichi; Katsumata, Kenji; Tsuchida, Akihiko

    2018-04-01

    We started robot-assisted thoracoscopic esophagectomy using the da Vinci surgical system from June 2010 and operated on 30 cases by December 2013. Herein, we examined the usefulness of robot-assisted thoracoscopic esophagectomy and compared it with conventional esophagectomy by right thoracotomy. Patients requiring an invasion depth of up to the muscularis propria with preoperative diagnosis were considered for surgical adaptation, excluding bulky lymph node metastasis or salvage surgery cases. The outcomes of 30 patients who underwent robot-assisted surgery (robot group) and 30 patients who underwent conventional esophagectomy by right thoracotomy (thoracotomy group) up to December 2013 were retrospectively examined. Five ports were used in the robot-assisted thoracoscopic esophagectomy: 3rd intercostal (da Vinci right arm), 6th intercostal (da Vinci camera), 9th intercostal (da Vinci left arm), 4th and 8th intercostals (for assistance). There was no significant difference in patient characteristics. Robot group/right thoracotomy group: Operation time, 563/398 min; thoracic procedure bleeding volume, 21/135 ml; number of thoracic lymph node radical dissections, 25/23. Postoperative complications were recurrent nerve paralysis, 16.7/16.7%; pneumonia, 6.7%/10.0%; anastomotic leakage, 10.0/20.0%; surgical site infection, 0/10.0%; hospitalization, 17/30 days. For the robot group, the operation time was significantly longer, but the amount of intraoperative bleeding and postoperative hospitalization were significantly reduced. Robot-assisted thoracoscopic esophagectomy enables delicate surgical procedures owing to the 3D effect of the field of view and articulated forceps of the da Vinci. This procedure reduces bleeding and postoperative hospitalization and is less invasive than conventional esophagectomy by right thoracotomy.

  9. Robot-Assisted Transoral Odontoidectomy : Experiment in New Minimally Invasive Technology, a Cadaveric Study

    PubMed Central

    Yang, Moon Sul; Yoon, Tae Ho; Yoon, Do Heum; Kim, Keung Nyun; Pennant, William

    2011-01-01

    Objective In the field of spinal surgery, a few laboratory results or clinical cases about robotic spinal surgery have been reported. In vivo trials and development of related surgical instruments for spinal surgery are required before its clinical application. We investigated the use of the da Vinci® Surgical System in spinal surgery at the craniovertebral junction in a human cadaver to demonstrate the efficacy and pitfalls of robotic surgery. Methods Dissection of pharyngeal wall to the exposure of C1 and odontoid process was performed with full robotic procedure. Although assistance of another surgeon was necessary for drilling and removal of odontoid process due to the lack of appropriate end-effectors, successful robotic procedures for dural sutures and exposing spinal cord proved its safety and dexterity. Results Robot-assisted odontoidectomy was successfully performed in a human cadaver using the da Vinci® Surgical System with few robotic arm collisions and minimal soft tissue damages. Da Vinci® Surgical System manifested more dexterous movement than human hands in the deep and narrow oral cavity. Furthermore, sutures with robotic procedure in the oral cavity demonstrated the advantage over conventional procedure. Conclusion Presenting cadaveric study proved the probability of robot-assisted transoral approach. However, the development of robotic instruments specific to spinal surgery must first precede its clinical application. PMID:21607188

  10. The role of the assistant during robot-assisted partial nephrectomy: does experience matter?

    PubMed

    Potretzke, Aaron M; Knight, Brent A; Brockman, John A; Vetter, Joel; Figenshau, Robert S; Bhayani, Sam B; Benway, Brian M

    2016-06-01

    The objective of this study was to evaluate surgical outcomes with respect to the experience level of the bedside assistant during robot-assisted partial nephrectomy. A retrospective review was conducted of a prospectively maintained database of 414 consecutive robot-assisted laparoscopic partial nephrectomies performed by experienced robotic surgeons at our institution from April 2011 to September 2014. A senior-level assistant was defined as a resident in his or her post-graduate year (PGY) 4 or 5, or a fellow. Junior-level assistants were considered to be PGY-2, PGY-3, or a nurse first assistant. Multivariate analyses were performed using linear, Poisson, and logistic regression models. There were 115 junior-level cases and 299 senior-level cases. On univariate analysis, the experience level of the assistant had no impact on operative time (168 for junior level vs. 163 min for senior level, p = 0.656). Likewise, there were no differences between the junior- and senior-level groups with regard to warm ischemia time (21.3 vs. 20.9 min, p = 0.843), negative margin status (111/115 (96.5 %) vs. 280/299 (93.6 %), p = 0.340), or postoperative complications (17/115 (14.8 %) vs. 35/299 (11.7 %), p = 0.408). After multivariate analysis, operative time was associated with increased body mass index and tumor size (both p < 0.001), but not with resident experience level (p = 0.051). Estimated blood loss and postoperative complications were also not associated with the PGY of the assistant (p = 0.488 and p = 0.916, respectively). Despite common concern, the PGY status of a physician trainee serving as the bedside assistant does not appear to influence the outcomes of robot-assisted partial nephrectomy at a high-volume center.

  11. A Novel Telemanipulated Robotic Assistant for Surgical Endoscopy: Preclinical Application to ESD.

    PubMed

    Zorn, Lucile; Nageotte, Florent; Zanne, Philippe; Legner, Andras; Dallemagne, Bernard; Marescaux, Jacques; de Mathelin, Michel

    2018-04-01

    Minimally invasive surgical interventions in the gastrointestinal tract, such as endoscopic submucosal dissection (ESD), are very difficult for surgeons when performed with standard flexible endoscopes. Robotic flexible systems have been identified as a solution to improve manipulation. However, only a few such systems have been brought to preclinical trials as of now. As a result, novel robotic tools are required. We developed a telemanipulated robotic device, called STRAS, which aims to assist surgeons during intraluminal surgical endoscopy. This is a modular system, based on a flexible endoscope and flexible instruments, which provides 10 degrees of freedom (DoFs). The modularity allows the user to easily set up the robot and to navigate toward the operating area. The robot can then be teleoperated using master interfaces specifically designed to intuitively control all available DoFs. STRAS capabilities have been tested in laboratory conditions and during preclinical experiments. We report 12 colorectal ESDs performed in pigs, in which large lesions were successfully removed. Dissection speeds are compared with those obtained in similar conditions with the manual Anubiscope platform from Karl Storz. We show significant improvements ( ). These experiments show that STRAS (v2) provides sufficient DoFs, workspace, and force to perform ESD, that it allows a single surgeon to perform all the surgical tasks and those performances are improved with respect to manual systems. The concepts developed for STRAS are validated and could bring new tools for surgeons to improve comfort, ease, and performances for intraluminal surgical endoscopy.

  12. Retroperitoneal access for robotic renal surgery.

    PubMed

    Anderson, Barrett G; Wright, Alec J; Potretzke, Aaron M; Figenshau, R Sherburne

    2018-01-01

    Retroperitoneal access for robotic renal surgery is an effective alternative to the commonly used transperitoneal approach. We describe our contemporary experience and technique for attaining retroperitoneal access. We outline our institutional approach to retroperitoneal access for the instruction of urologists at the beginning of the learning curve. The patient is placed in the lateral decubitus position. The first incision is made just inferior to the tip of the twelfth rib as described by Hsu, et al. After the lumbodorsal fascia is traversed, the retroperitoneal space is dilated with a round 10 millimeter AutoSutureTM (Covidien, Mansfield, MA) balloon access device. The following trocars are used: A 130 millimeter KiiR balloon trocar (Applied Medical, Rancho Santa Margarita, CA), three robotic, and one assistant. Key landmarks for the access and dissection are detailed. 177 patients underwent a retroperitoneal robotic procedure from 2007 to 2015. Procedures performed include 158 partial nephrectomies, 16 pyeloplasties, and three radical nephrectomies. The robotic fourth arm was utilized in all cases. When compared with the transperitoneal approach, the retroperitoneal approach was associated with shorter operative times and decreased length of stay (1). Selection bias and surgeon preference accounted for the higher proportion of patients who underwent partial nephrectomy off-camp via the retroperitoneal approach. Retroperitoneal robotic surgery may confer several advantages. In patients with previous abdominal surgery or intra-abdominal conditions, the retroperitoneum can be safely accessed while avoiding intraperitoneal injuries. The retroperitoneum also provides a confined space that may minimize the sequelae of potential complications including urine leak. Moreover, at our institution, retroperitoneal robotic surgery is associated with shorter operative times and a decreased length of stay when compared with the transperitoneal approach (2). In selected patients, the retroperitoneal approach is a viable alternative to the transperitoneal approach for a variety of renal procedures. Copyright® by the International Brazilian Journal of Urology.

  13. Planned nerve preservation to reduce positive surgical margins during robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Zorn, Kevin C; Gofrit, Ofer N; Steinberg, Gary P; Taxy, Jerome B; Zagaja, Gregory P; Shalhav, Arieh L

    2008-06-01

    The main objective of radical prostatectomy (RP) is optimal oncologic resection with preservation of sexual function (SF). During our initial experience with robot-assisted laparoscopic radical prostatectomy (RLRP), we noted a high rate of posterolateral location of positive surgical margins (PSM) with nerve preservation (NP). With its magnified view of the surgical field and improved instrument precision, one potential advantage of RLRP is the ability to tailor the degree of NP. We evaluated the effect of a protocol for side-specific NP based on preoperative variables on PSM rates and SF outcomes. Between June and November 2006, 150 consecutive RLRPs were performed using a surgical protocol to select side-specific NP techniques (interfascial [IF], partial extrafascial [pEF], and wide extrafascial resection [WEFR]) based on preoperative risk factors (clinical stage, biopsy Gleason score, percentage of positive cores and maximal core cancer percentage, and preoperative PSA). Pathologic and SF outcomes in these patients were compared with those of a control group of 245 consecutive RLRPs in whom non-selective IF dissection was performed. All data were prospectively collected. Mean patient age, PSA, clinical stage, biopsy Gleason score and positive core involvement, pathologic Gleason score, and stage were comparable among the two groups. The overall PSM rate (12.6% nu 20.4%; P = 0.04) and posterolateral location of PSMs (37% nu 70%; P = 0.04) were significantly lower in the study group. At 12 months, potency was reported in 80%, 67%, and 11% of men undergoing bilateral IFNP, partial extrafascial nerve preservation (pEFNP), and WEFR, respectively (P = 0.27). Planning side-specific NP during RLRP, according to selected preoperative variables, can significantly reduce overall and posterolateral PSM rates. Furthermore, partial nerve sparing (pEFNP) also appears to confer favorable early SF outcomes.

  14. A Novel Approach for Apical Dissection During Robot-assisted Radical Prostatectomy: The "Collar" Technique.

    PubMed

    Bianchi, Lorenzo; Turri, Filippo Maria; Larcher, Alessandro; De Groote, Ruben; De Bruyne, Peter; De Coninck, Vincent; Goossens, Marijn; D'Hondt, Frederiek; De Naeyer, Geert; Schatteman, Peter; Mottrie, Alexandre

    2018-02-02

    Apical dissection in robot-assisted radical prostatectomy (RARP) affects not only cancer control, but also continence recovery. To describe a novel approach for apical dissection, the collar technique, to reduce apical positive surgical margins (PSMs). A total of 189 consecutive patients (81 in the control group, 108 in the collar technique group) underwent RARP at a single center. rates of apical PSMs; secondary outcome: urinary continence. The urethral sphincter complex is incised 2-3mm distally to the apex, to stay farther from it and reduce PSMs; the underlying smooth muscle is exposed and incised closer to the apex to preserve the maximal length of the lissosphincter. Mann-Whitney U and chi-square tests compared median and proportions between the two groups, respectively. Univariate logistic regression tested the association between technique employed and risk of apical PSMs. Fourteen patients (7.4%) revealed apical PSMs (9.9% in the control group, 5.6% in the collar group; p=0.7). When the collar technique was used, significantly lower rates of apical PSMs occurred in pT2 disease (0% vs 7.1%; p=0.03). In case of apical tumor at preoperative magnetic resonance imaging (MRI; n=43), the collar technique determined significantly lower overall (9.7% vs 42%) and apical (3.2% vs 42%) PSMs (all p≤0.02). Continence recovery in the collar and control groups was similar. When preoperative MRI showed an apical tumor, the collar technique had a significantly lower risk of apical PSMs (odds ratio: 0.05, p=0.009). The collar technique reduces the rates of apical PSMs in case of apical tumor, preserving the length of the lissosphincter. We describe a novel approach for apical dissection during robot-assisted radical prostatectomy. Our technique reduces the rates of apical surgical margins in case of apical tumor at preoperative magnetic resonance imaging and leads to optimal continence recovery. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  15. Robot-assisted Salvage Lymph Node Dissection for Clinically Recurrent Prostate Cancer.

    PubMed

    Montorsi, Francesco; Gandaglia, Giorgio; Fossati, Nicola; Suardi, Nazareno; Pultrone, Cristian; De Groote, Ruben; Dovey, Zach; Umari, Paolo; Gallina, Andrea; Briganti, Alberto; Mottrie, Alexandre

    2017-09-01

    Salvage lymph node dissection has been described as a feasible treatment for the management of prostate cancer patients with nodal recurrence after primary treatment. To report perioperative, pathologic, and oncologic outcomes of robot-assisted salvage nodal dissection (RASND) in patients with nodal recurrence after radical prostatectomy (RP). We retrospectively evaluated 16 patients affected by nodal recurrence following RP documented by positive positron emission tomography/computed tomography scan. Surgery was performed using DaVinci Si and Xi systems. A pelvic nodal dissection that included lymphatic stations overlying the external, internal, and common iliac vessels, the obturator fossa, and the presacral nodes was performed. In 13 (81.3%) patients a retroperitoneal lymph node dissection that included all nodal tissue located between the aortic bifurcation and the renal vessels was performed. Perioperative outcomes consisted of operative time, blood loss, length of hospital stay, and complications occurred within 30 d after surgery. Biochemical response (BR) was defined as a prostate-specific antigen level <0.2 ng/ml at 40 d after RASND. Median operative time, blood loss, and length of hospital stay were 210min, 250ml, and 3.5 d. The median number of nodes removed was 16.5. Positive lymph nodes were detected in 11 (68.8%) patients. Overall, four (25.0%) and five (31.2%) patients experienced intraoperative and postoperative complications, respectively. Overall, one (6.3%) and four (25.0%) patients had Clavien I and II complications within 30 d after RASND, respectively. Overall, five (33.3%) patients experienced BR after surgery. Our study is limited by the small cohort of patients evaluated and by the follow-up duration. RASND represents a feasible procedure in patients with nodal recurrence after RP and provides acceptable short-term oncologic outcomes, where one out of three patients experience BR immediately after surgery. Long-term data are needed to confirm the effectiveness of this approach. We report our initial experience with robot-assisted salvage nodal dissection for the management of patients with lymph node recurrence after radical prostatectomy. This technique represents a feasible and effective approach, where no high-grade complications were recorded and one out of three patients experienced biochemical response at 40 d after surgery. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  16. Integrating robotic partial nephrectomy to an existing robotic surgery program.

    PubMed

    Yuh, Bertram; Muldrew, Shantel; Menchaca, Anita; Yip, Wesley; Lau, Clayton; Wilson, Timothy; Josephson, David

    2012-04-01

    As more centers develop robotic proficiency, progressing to a successful robot-assisted partial nephrectomy (RAPN) program depends on a number of factors. We describe our technique, results, and analysis of program setup for RAPN. Between 2005 and 2011, 92 RAPNs were performed following maturation of a robotic prostatectomy program. Operating rooms and supply rooms were outfitted for efficient robotic throughput. Tilepro and intraoperative ultrasound were used for all cases. Training and experiential learning for surgeons, anesthesia and nursing staff was a high priority. An onsite robotic technician helped troubleshoot, prepare the room and staff prior to starting surgery, and provide assistance with different robotic models. Average operative time decreased over time from 235 min to 199 min (p = .03). Warm ischemia time decreased from 26 minutes to 23 minutes (p = .02) despite an increased complexity of tumors and operations on multiple tumors. Median estimated blood loss was 150 mL. Average length of hospital stay was 3 days (range 1-9). Average size of lesions was 2.7 cm (range 0.7-8.6). Final pathology demonstrated 71 (77%) malignant lesions and 21 (23%) benign lesions. The addition of a robot-assisted partial nephrectomy program to an institutional robotic program can be coordinated with several key steps. Outcomes from an operational, oncologic, and renal functional standpoint are acceptable. Despite increased complexity of tumors and treatment of multiple lesions, operative and warm ischemia times showed a decrease over time. An organizational model that involves the surgeons, anesthesia, nursing staff, and possibly a robotic technical specialist helps to overcome the learning curve.

  17. [Robot-assisted minimally invasive lobectomy with systematic lymphadenectomy for lung cancer].

    PubMed

    Egberts, J-H; Schlemminger, M; Schafmayer, C; Dohrmann, P; Becker, T

    2015-02-01

    Lobectomy for lung cancer is the standard therapy for lung cancer in limited stages. The adoption of minimally invasive lobectomy (video-assisted thoracic surgery or VATS lobectomy) has increased worldwide since its first description more than 15 years ago. However, the VATS technique has a long learning curve and sometimes limitations in terms of precise preparation and presentability of the central structures of the lung hilus due to the limited mobility of the standard thoracoscopic instruments. By using a four-arm robotic platform (DaVinci®), not only the preparation of the hilus structures but also the central lymphadenectomy can be performed in a comfortable and safe way under a clear and precise view. Surgical treatment of locally limited lung cancer in the right lower lobe (squamous cell carcinoma). Robot-assisted, minimally invasive right lower lobectomy with systematic lymphadenectomy. Robot-assisted minimal invasive lobectomy is feasible with special regard to oncological and technical aspects. Especially the intrathoracic precise dissection of the tissue under a perfect view allow a comfortable and safe operation technique. Georg Thieme Verlag KG Stuttgart · New York.

  18. Incidence and location of positive surgical margin among open, laparoscopic and robot-assisted radical prostatectomy in prostate cancer patients: a single institutional analysis.

    PubMed

    Koizumi, Atsushi; Narita, Shintaro; Nara, Taketoshi; Takayama, Koichiro; Kanda, Sohei; Numakura, Kazuyuki; Tsuruta, Hiroshi; Maeno, Atsushi; Huang, Mingguo; Saito, Mitsuru; Inoue, Takamitsu; Tsuchiya, Norihiko; Satoh, Shigeru; Nanjo, Hiroshi; Habuchi, Tomonori

    2018-06-19

    To evaluate the positive surgical margin rates and locations in radical prostatectomy among three surgical approaches, including open radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted radical prostatectomy. We retrospectively reviewed clinical outcomes at our institution of 450 patients who received radical prostatectomy. Multiple surgeons were involved in the three approaches, and a single pathologist conducted the histopathological diagnoses. Positive surgical margin rates and locations among the three approaches were statistically assessed, and the risk factors of positive surgical margin were analyzed. This study included 127, 136 and 187 patients in the open radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted radical prostatectomy groups, respectively. The positive surgical margin rates were 27.6% (open radical prostatectomy), 18.4% (laparoscopic radical prostatectomy) and 13.4% (robot-assisted radical prostatectomy). In propensity score-matched analyses, the positive surgical margin rate in the robot-assisted radical prostatectomy was significantly lower than that in the open radical prostatectomy, whereas there was no significant difference in the positive surgical margin rates between robot-assisted radical prostatectomy and laparoscopic radical prostatectomy. In the multivariable analysis, PSA level at diagnosis and surgical approach (open radical prostatectomy vs robot-assisted radical prostatectomy) were independent risk factors for positive surgical margin. The apex was the most common location of positive surgical margin in the open radical prostatectomy and laparoscopic radical prostatectomy groups, whereas the bladder neck was the most common location in the robot-assisted radical prostatectomy group. The significant difference of positive surgical margin locations continued after the propensity score adjustment. Robot-assisted radical prostatectomy may potentially achieve the lowest positive surgical margin rate among three surgical approaches. The bladder neck was the most common location of positive surgical margin in robot-assisted radical prostatectomy and apex in open radical prostatectomy and laparoscopic radical prostatectomy. Although robot-assisted radical prostatectomy may contribute to the reduction of positive surgical margin, dissection of the bladder neck requires careful attention to avoid positive surgical margins.

  19. Robot-assisted Sistrunk's operation, total thyroidectomy, and neck dissection via a transaxillary and retroauricular (TARA) approach in papillary carcinoma arising in thyroglossal duct cyst and thyroid gland.

    PubMed

    Byeon, Hyung Kwon; Ban, Myung Jin; Lee, Jeon Mi; Ha, Jong Gyun; Kim, Eun Sung; Koh, Yoon Woo; Choi, Eun Chang

    2012-12-01

    Carcinomas arising in the thyroglossal duct cysts are rare, accounting only for about 0.7-1.5 % of all thyroglossal duct cysts. Synchronous occurrence of thyroglossal duct carcinoma and thyroid carcinoma is reported to be even rarer. Traditionally, surgical treatments of such coexisting thyroglossal duct cyst carcinoma (TGDCa) and papillary thyroid carcinoma (PTC) were typically performed through a single transverse or double incisions on the overlying skin. A longer, extended cervical incision might be required if neck dissection is necessary. Though this method provides the operator with the optimal surgical view, the detrimental cosmetic effect on the patient of possessing a scar cannot be avoided, despite the effort of the surgeon to camouflage the scar by placing the incision in natural skin creases. Recently, the authors have previously reported the feasibility of robot-assisted neck dissections via a transaxillary and retroauricular ("TARA") approach or modified face-lift approach in early head and neck cancers. On the basis of the forementioned surgical technique, we demonstrate our novel technique for robot-assisted Sistrunk's operation via retroauricular approach as well as robot-assisted neck dissection with total thyroidectomy via transaxillary approach. This is a case presentation of a 22-year-old woman with synchronous TGDCa and PTC with minimal lymph node metastasis who underwent resection of TGDCa and total thyroidectomy with left neck level III and IV lymph node dissection as well as central compartment lymph node dissection (CCND) via TARA approach with a robotic surgery system after approval from the institutional review board at Severance Hospital, Yonsei University College of Medicine. The incision was just like the TARA approach in head and neck cancer, which has been reported by our institute. The operation was proceeded as follows. First, excision of the TGDCa through the retroauricular incision was done followed by total thyroidectomy with CCND via transaxillary approach. Finally, neck dissection of left level III, IV was conducted via transaxillary approach. The da Vinci surgical system (Intuitive Surgical, Sunnyvale, CA) was introduced via retroauricular or transaxillary port. A 30° dual-channel endoscope was used, and the two instrument arms were equipped with 5 mm Maryland forceps and a 5 mm spatula monopolar cautery for TGDCa excision via retroauricular approach. When conducting total thyroidectomy and neck dissection via transaxillary approach, three instrument arms were utilized, each equipped with 5 mm Maryland forceps, ProGrasp forceps and a 5 mm spatula monopolar cautery or Harmonic curved shears. The rest of the surgery was completed with the robotic system (see Video). The operative procedure was successfully completed utilizing the robotic surgical system with no conversion to open surgery. The operation time for TGDCa excision was 97 min, including the time for skin flap elevation (15 min), setting up the robotic system (5 min), and console time using the robotic system (77 min). Also, the total operation time for the consecutive total thyroidectomy with CCND and level III, IV dissection was 142 min including the time for skin flap elevation (27 min), setting up the robotic system (3 min), and console time using the robotic system (112 min). There were no intraoperative complications. The retroauricular approach for the removal of the TGDCa allowed for an excellent magnified surgical view revealing important structures of the local anatomy. It also created sufficient space for the cutting of the relevant portion of the hyoid bone. Handling of the robotic instruments through the incision was technically feasible and safe without any mutual collisions throughout the operation. The patient's postoperative parathyroid hormone (PTH) level was within normal range and functions of her both vocal cords were intact. The histopathologic results of the specimens revealed thyroglossal duct cyst with internal papillary carcinoma measuring 1.1 cm with infiltrative tumor margins and papillary microcarcinoma measuring 0.9 cm within the left thyroid lobe with extrathyroidal soft tissue extension. There was no evidence of tumor in the right lobe and the pyramidal lobe of the thyroid gland. As for the lymph nodes resected, 7 out of 9 paratracheal nodes and 2 out of 7 left level III, IV nodes revealed metastatic carcinomas. The patient was discharged on the 8th day after the operation with no complications. The patient was extremely satisfied with the cosmetic results. The patient has received high-dose radioiodine ablation (RAI) therapy and is currently doing well with no evidence of recurrence. Although there is still a great deal of controversy regarding the treatment of TGDCa, there is little debate that for the cases of synchronous TGDCa and PTC, total thyroidectomy in addition to the Sistrunk procedure must be performed. As for the patient in our case where left level IV lymph node metastasis was detected under preoperative ultrasonography (USG), if the usual method of surgical procedure was to be selected, double incisions or a single extended transverse incision must be adopted for the Sistrunk's operation and total thyroidectomy with lateral neck dissection. The conventional method to remove neck masses was to do so by placing an incision on the overlying skin. This 'open' approach to viewing the lesion has an advantage of providing the operator with the best surgical view, but the recognizable surgical scar that results from the surgery can be displeasing for patients. Therefore the surgeon can try to make a small incision and camouflage the scar by placing the incision in natural skin creases, yet the cosmetic results can still be displeasing for the patient due to its visibility and permanence. This can be an even greater problem if the patient is young and an active member of his/her society and if the lesion is benign or low-grade malignancy which can be simply dissected and excised. Therefore it is the surgeon's best interest to perform an operation successfully with a 'least obvious' or 'hidden' scar whenever possible. Accordingly, we have adopted a novel approach, the transaxillary and retroauricular approach, in view of our increasing surgical experience with various indications such as submandibular gland (SMG) resections and neck dissections in head and neck cancer or thyroid papillary carcinoma. Some investigators have demonstrated that robot-assisted neck dissections performed on patients with thyroid cancer and lateral neck node metastasis are feasible and safe. We conducted total thyroidectomy with bilateral CCND and level III and IV dissection using the same approach. Although the technical feasibility and safety of neck dissection or SMG resection via retroauricular approach has already been reported previously at our institute, Sistrunk's operation via retroauricular approach will be challenging. In spite of that, we were able to demonstrate successfully Sistrunk's operation including the hyoid bone resection through the retroauricular approach. There are however, certain areas of potential difficulties which must be considered with caution during the operation procedure. First, when removing the TGDCa through the retroauricular port, identification of the ipsilateral hyoid bone is primarily important and it is also crucial that dissection along the capsule must be done carefully so as not to rupture the tumor. It is essential that sufficient working space must be created for the comfortable movement of the robotic arms through the retroauricular port and in order to do so, sufficient skin flap elevation in both superior and inferior directions must be performed. It is necessary to elevate the superior skin flap up to the level of the inferior border of the mandible but during this process, the platysma muscle must be identified and meticulous dissection along the subplatysmal plane must be carried out so as not to damage the marginal mandibular branch of the facial nerve. Another area of potential pitfalls concerns the total thyroidectomy with neck dissection through the transaxillary port. Sufficient amount of working space must be secured in order to perform comfortably the contralateral thyroidectomy and neck dissection and in order to do so, skin flap elevation must be done at least 2 cm further based on the ipsilateral omohyoid muscle and the contralateral thyroid gland must be adequately exposed. Using the robotic surgical system in removing the thyroglossal duct cyst, the free movement of wristed instrumentation through the retroauricular incision allowed for efficient dissection and easy handling of the tissue. In this particular case we could not identify the tract beyond the hyoid and up to the foramen cecum, but we anticipate that there would be no technical problems of dissection and excision had it been so. To our knowledge, Sistrunk's operation and total thyroidectomy with lateral neck dissection via TARA approach utilizing the robotic surgical system has never been attempted before. It has some advantages over the conventional surgery in terms of cosmesis. However, careful consideration in selecting appropriate cases is required and prospective trials should be conducted to recognize long-term outcomes and to overcome potential limitations.

  20. A novel technique for robot assisted latissimus dorsi flap harvest.

    PubMed

    Chung, Jae-Hyun; You, Hi-Jin; Kim, Hyon-Surk; Lee, Byung-Il; Park, Seung-Ha; Yoon, Eul-Sik

    2015-07-01

    A robotic surgery technique of harvesting the latissimus dorsi muscle flap has technical advantages over endoscopic harvest and cosmetic advantages over the open technique. The authors introduce a new transaxillary gasless technique using an articulated long retractor for robot assisted latissimus dorsi flap harvest. Twelve robot assisted latissimus dorsi muscle flaps were harvested: 3 cases of delayed reconstruction following tissue expander insertion or breast conserving surgery; 4 cases of immediate reconstruction following nipple-sparing mastectomy; and 5 cases of chest wall deformity correction in patients with Poland syndrome. A specially designed articulated long retractor was used to maintain adequate working space and enable latissimus dorsi muscle dissection without gas insufflation. Twelve muscle flaps were successfully harvested in 12 patients without converting to an open technique. The mean docking time was 54.6 min, and the mean operative time and robotic time were 400.4 min and 85.8 min, respectively. There were no donor site complications or flap problems. Average follow-up was 15.7 months. All patients were satisfied with their esthetic results, especially the absence of visible scars. The novel robot assisted latissimus dorsi harvest technique is a safe alternative to the conventional method. Copyright © 2015. Published by Elsevier Ltd.

  1. Current controversies and challenges in robotic-assisted, laparoscopic, and open partial nephrectomies.

    PubMed

    Laviana, Aaron A; Hu, Jim C

    2014-06-01

    Recent studies demonstrate that partial versus radical nephrectomy confers a survival advantage while lowering the risk of severe chronic kidney disease. Open partial nephrectomy remains the gold standard, but the use of minimally invasive approaches is expanding. Using a MEDLINE literature search, we reviewed all relevant literature between 2000 and 2014. Fifty-one articles were left for review after filtering for inclusion of trends, learning curve, perioperative outcomes, warm ischemia time, and costs. Partial nephrectomy use has increased over the past decade accounting for 24.7 % of all surgeries performed for the treatment of organ-confined renal masses in 2008. The introduction of robotic technology has continued to alter the landscape accounting for 47 % of all partial nephrectomies at academic US centers in 2011, though a center bias and publication bias likely exist. A slower adoption rate has been seen at non-academic centers and those in low-income areas. The learning curve for robotic-assisted laparoscopic nephrectomy has been shorter than for laparoscopic partial nephrectomy, explaining, in part, why the rate of partial nephrectomy remained relatively stagnant before the robotic-assisted laparoscopic nephrectomy, despite an increase in the detection of small renal masses. Operative and warm ischemia time remain shortest for open partial nephrectomy, though it is associated with the highest blood loss and longest hospital stay. Finally, open partial nephrectomy remains the least costly modality. Each approach to partial nephrectomy has its advantages and disadvantages, and continued effort must be applied to comparative effectiveness research for nephron-sparing treatments for renal cell carcinoma.

  2. A rare case of acute presentation of trocar site hernia from robot-assisted laparoscopic partial nephrectomy.

    PubMed

    Ng, Zi Qin; Pemberton, Richard; Tan, Patrick

    2018-02-15

    Trocar site hernia is not a common acute complication encountered after robot-assisted surgery, especially in the urological cohort of patients. A few case reports of small bowel obstruction secondary to incarceration by trocar site hernia have been described in gynaecological surgery and prostatectomies. As the clinical presentation is non-specific, late diagnosis has significant implication on morbidity and mortality. Here, we present a rare case of a patient with recent robot-assisted laparoscopic partial nephrectomy for a renal cell carcinoma presented with features of impending bowel obstruction secondary to incarcerated small bowel in the trocar site. We also reviewed the literature focusing on clinical features of trocar site hernia and preventive measures.

  3. Feasibility and accuracy of computational robot-assisted partial nephrectomy planning by virtual partial nephrectomy analysis.

    PubMed

    Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; China, Toshiyuki; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Horie, Shigeo

    2015-05-01

    To evaluate the feasibility and accuracy of virtual partial nephrectomy analysis, including a color-coded three-dimensional virtual surgical planning and a quantitative functional analysis, in predicting the surgical outcomes of robot-assisted partial nephrectomy. Between 2012 and 2014, 20 patients underwent virtual partial nephrectomy analysis before undergoing robot-assisted partial nephrectomy. Virtual partial nephrectomy analysis was carried out with the following steps: (i) evaluation of the arterial branch for selective clamping by showing the vascular-supplied area; (ii) simulation of the optimal surgical margin in precise segmented three-dimensional model for prediction of collecting system opening; and (iii) detailed volumetric analyses and estimates of postoperative renal function based on volumetric change. At operation, the surgeon identified the targeted artery and determined the surgical margin according to the virtual partial nephrectomy analysis. The surgical outcomes between the virtual partial nephrectomy analysis and the actual robot-assisted partial nephrectomy were compared. All 20 patients had negative cancer surgical margins and no urological complications. The tumor-specific renal arterial supply areas were shown in color-coded three-dimensional model visualization in all cases. The prediction value of collecting system opening was 85.7% for sensitivity and 100% for specificity. The predicted renal resection volume was significantly correlated with actual resected specimen volume (r(2) = 0.745, P < 0.001). The predicted estimated glomerular filtration rate was significantly correlated with actual postoperative estimated glomerular filtration rate (r(2) = 0.736, P < 0.001). Virtual partial nephrectomy analysis is able to provide the identification of tumor-specific renal arterial supply, prediction of collecting system opening and prediction of postoperative renal function. This technique might allow urologists to compare various arterial clamping methods and resection margins with surgical outcomes in a non-invasive manner. © 2015 The Japanese Urological Association.

  4. Health resource use after robot-assisted surgery vs open and conventional laparoscopic techniques in oncology: analysis of English secondary care data for radical prostatectomy and partial nephrectomy.

    PubMed

    Hughes, David; Camp, Charlotte; O'Hara, Jamie; Adshead, Jim

    2016-06-01

    To evaluate postoperative health resource utilisation and secondary care costs for radical prostatectomy and partial nephrectomy in National Health Service (NHS) hospitals in England, via a comparison of robot-assisted, conventional laparoscopic and open surgical approaches. We retrospectively analysed the secondary care records of 23 735 patients who underwent robot-assisted (RARP, n = 8 016), laparoscopic (LRP, n = 6 776) or open radical prostatectomy (ORP, n = 8 943). We further analysed 2 173 patients who underwent robot-assisted (RAPN, n = 365), laparoscopic (LPN, n = 792) or open partial nephrectomy (OPN, n = 1 016). Postoperative inpatient admissions, hospital bed-days, excess bed-days and outpatient appointments at 360 and 1 080 days after surgery were reviewed. Patients in the RARP group required significantly fewer inpatient admissions, hospital bed-days and excess bed-days at 360 and 1 080 days than patients undergoing ORP. Patients undergoing ORP had a significantly higher number of outpatient appointments at 1 080 days. The corresponding total costs were significantly lower for patients in the RARP group at 360 days (£1679 vs £2031 for ORP; P < 0.001) and at 1 080 days (£3461 vs £4208 for ORP; P < 0.001). In partial nephrectomy, Patients in the RAPN group required significantly fewer inpatient admissions and hospital bed-days at 360 days compared with those in the OPN group; no significant differences were observed in outcomes at 1 080 days. The corresponding total costs were lower for patients in the RAPN group at 360 days (£779 vs £1242 for OPN, P = 0.843) and at 1 080 days (£2122 vs £2889 for ORP; P = 0.570). For both procedure types, resource utilisation and costs for laparoscopic surgeries lay at the approximate midpoint of those for robot-assisted and open surgeries. Our analysis provides compelling evidence to suggest that RARP leads to reduced long-term health resource utilisation and downstream cost savings compared with traditional open and laparoscopic approaches. Furthermore, despite the limitations that arise from the inclusion of a small sample, these results also suggest that robot-assisted surgery may represent a cost-saving alternative to existing surgical options in partial nephrectomy. Further exploration of clinical cost drivers, as well as an extension of the analysis into subsequent years, could lend support to the wider commissioning of robot-assisted surgery within the NHS. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  5. Early experience using the da Vinci Surgical System for the treatment of mediastinal tumors.

    PubMed

    Kajiwara, Naohiro; Taira, Masahiro; Yoshida, Koichi; Hagiwara, Masaru; Kakihana, Masatoshi; Usuda, Jitsuo; Uchida, Osamu; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2011-10-01

    The da Vinci Surgical System has been used in only a few cases for treating mediastinal tumors in Japan. Recently, we used the da Vinci Surgical System for various types of anterior and middle mediastinal tumors in clinical practice. We report our early experience using the da Vinci Surgical System. Seven patients gave written informed consent to undergo robotic surgery for mediastinal tumor dissection using the da Vinci Surgical System. We evaluated the safety and feasibility of this system for the surgical treatment of mediastinal tumors. Two specialists in thoracic surgery who are certified to use the da Vinci S Surgical System and another specialist acted as an assistant performed the tumor dissection. We were able to access difficult-to-reach areas, such as the mediastinum, safely. All the resected tumors were classified as benign tumors histologically. The average da Vinci setting time was 14.0 min, the average working time was 55.7 min, and the average overall operating time was 125.9 min. The learning curve for the da Vinci setup and manipulation time was short. Robotic surgery enables mediastinal tumor dissection in certain cases more safely and easily than conventional video-assisted thoracoscopic surgery and less invasively than open thoracotomy.

  6. Learning curve for robotic-assisted surgery for rectal cancer: use of the cumulative sum method.

    PubMed

    Yamaguchi, Tomohiro; Kinugasa, Yusuke; Shiomi, Akio; Sato, Sumito; Yamakawa, Yushi; Kagawa, Hiroyasu; Tomioka, Hiroyuki; Mori, Keita

    2015-07-01

    Few data are available to assess the learning curve for robotic-assisted surgery for rectal cancer. The aim of the present study was to evaluate the learning curve for robotic-assisted surgery for rectal cancer by a surgeon at a single institute. From December 2011 to August 2013, a total of 80 consecutive patients who underwent robotic-assisted surgery for rectal cancer performed by the same surgeon were included in this study. The learning curve was analyzed using the cumulative sum method. This method was used for all 80 cases, taking into account operative time. Operative procedures included anterior resections in 6 patients, low anterior resections in 46 patients, intersphincteric resections in 22 patients, and abdominoperineal resections in 6 patients. Lateral lymph node dissection was performed in 28 patients. Median operative time was 280 min (range 135-683 min), and median blood loss was 17 mL (range 0-690 mL). No postoperative complications of Clavien-Dindo classification Grade III or IV were encountered. We arranged operative times and calculated cumulative sum values, allowing differentiation of three phases: phase I, Cases 1-25; phase II, Cases 26-50; and phase III, Cases 51-80. Our data suggested three phases of the learning curve in robotic-assisted surgery for rectal cancer. The first 25 cases formed the learning phase.

  7. Surgical flow disruptions during robotic-assisted radical prostatectomy.

    PubMed

    Dru, Christopher J; Anger, Jennifer T; Souders, Colby P; Bresee, Catherine; Weigl, Matthias; Hallett, Elyse; Catchpole, Ken

    2017-06-01

    We sought to apply the principles of human factors research to robotic-assisted radical prostatectomy to understand where training and integration challenges lead to suboptimal and inefficient care. Thirty-four robotic-assisted radical prostatectomy and bilateral pelvic lymph node dissections over a 20 week period were observed for flow disruptions (FD) - deviations from optimal care that can compromise safety or efficiency. Other variables - physician experience, trainee involvement, robot model (S versus Si), age, body mass index (BMI), and American Society of Anesthesiologists (ASA) physical status - were used to stratify the data and understand the effect of context. Effects were studied across four operative phases - entry to insufflations, robot docking, surgical intervention, and undocking. FDs were classified into one of nine categories. An average of 9.2 (SD = 3.7) FD/hr were recorded, with the highest rates during robot docking (14.7 [SD = 4.3] FDs/hr). The three most common flow disruptions were disruptions of communication, coordination, and equipment. Physicians with more robotic experience were faster during docking (p < 0.003). Training cases had a greater FD rate (8.5 versus 10.6, p < 0.001), as did the Si model robot (8.2 versus 9.8, p = 0.002). Patient BMI and ASA classification yielded no difference in operative duration, but had phase-specific differences in FD. Our data reflects the demands placed on the OR team by the patient, equipment, environment and context of a robotic surgical intervention, and suggests opportunities to enhance safety, quality, efficiency, and learning in robotic surgery.

  8. Robot-assisted pudendal neurolysis in the treatment of pudendal nerve entrapment syndrome.

    PubMed

    Moscatiello, P; Carracedo Calvo, D; Yupanqui Guerra, L; Rivera Martínez, M E; Mendiola de la Hoza, A; Sánchez Encinas, M

    2018-06-01

    Pudendal nerve entrapment syndrome (PNE) is characterised by the presence of neuropathic pain in the pudendal nerve (PN) territory, associated or not with urinary, defecatory and sexual disorders. Surgical PN decompression is an effective and safe alternative for cases when conservative treatment fails. The aim of this study is to describe the first robot-assisted pudendal neurolysis procedure performed in our country. We describe step by step the technique of robot-assisted laparoscopic neurolysis of the left PN performed with intraoperative neurophysiological monitoring on a 60-year-old patient diagnosed with left PNE. The procedure was performed satisfactorily without complications. After 24h, the patient was discharged from the hospital. We observed a 50% reduction in pain measured using the visual analogue scale 2 weeks after the procedure, which remained after 10 weeks of the neurolysis. Robot-assisted neurolysis of the PN constitutes a feasible and safe approach, enabling better visualisation and accuracy in the dissection of the PN. Intraoperative neurophysiological monitoring is useful for locating the PN and for detecting intraoperative changes after the release of the nerve. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Risk factors for postoperative complications in robotic general surgery.

    PubMed

    Fantola, Giovanni; Brunaud, Laurent; Nguyen-Thi, Phi-Linh; Germain, Adeline; Ayav, Ahmet; Bresler, Laurent

    2017-03-01

    The feasibility and safety of robotically assisted procedures in general surgery have been reported from various groups worldwide. Because postoperative complications may lead to longer hospital stays and higher costs overall, analysis of risk factors for postoperative surgical complications in this subset of patients is clinically relevant. The goal of this study was to identify risk factors for postoperative morbidity after robotic surgical procedures in general surgery. We performed an observational monocentric retrospective study. All consecutive robotic surgical procedures from November 2001 to December 2013 were included. One thousand consecutive general surgery patients met the inclusion criteria. The mean overall postoperative morbidity and major postoperative morbidity (Clavien >III) rates were 20.4 and 6 %, respectively. This included a conversion rate of 4.4 %, reoperation rate of 4.5 %, and mortality rate of 0.2 %. Multivariate analysis showed that ASA score >3 [OR 1.7; 95 % CI (1.2-2.4)], hematocrit value <38 [OR 1.6; 95 % CI (1.1-2.2)], previous abdominal surgery [OR 1.5; 95 % CI (1-2)], advanced dissection [OR 5.8; 95 % CI (3.1-10.6)], and multiquadrant surgery [OR 2.5; 95 % CI (1.7-3.8)] remained independent risk factors for overall postoperative morbidity. It also showed that advanced dissection [OR 4.4; 95 % CI (1.9-9.6)] and multiquadrant surgery [OR 4.4; 95 % CI (2.3-8.5)] remained independent risk factors for major postoperative morbidity (Clavien >III). This study identifies independent risk factors for postoperative overall and major morbidity in robotic general surgery. Because these factors independently impacted postoperative complications, we believe they could be taken into account in future studies comparing conventional versus robot-assisted laparoscopic procedures in general surgery.

  10. Surgical complications associated with robotic urologic procedures in elderly patients.

    PubMed

    Cusano, Antonio; Haddock, Peter; Staff, Ilene; Jackson, Max; Abarzua-Cabezas, Fernando; Dorin, Ryan; Meraney, Anoop; Wagner, Joseph; Shichman, Steven; Kesler, Stuart

    2015-02-01

    Urologic malignancies are often diagnosed at an older age, and are increasingly managed utilizing robotic-assisted surgical techniques. As such, we assessed and compared peri-postoperative complication rates following robotic urologic surgery in elderly and younger patients. A retrospective analysis of IRB-approved databases and electronic medical records identified patients who underwent robotic-assisted urologic surgery between December 2003-September 2013. Patients were grouped according to surgical procedure (partial nephrectomy, radical cystectomy, radical prostatectomy) and age at surgery (≤ 74 or ≥ 75 years old). Associations between age, comorbidities, Charlson comorbidity index (CCI), and patient outcomes were evaluated within each surgery type. 97.5% and 2.5% of patients were ≤ 74 or ≥ 75 years old, respectively. Cystectomies, partial nephrectomies and prostatectomies accounted for 3.5%, 9.5% and 87.1% of surgeries, respectively. Within cystectomy, nephrectomy and prostatectomy groups, 24.4%, 12.5% and 0.6% patients were ≥ 75 years old. Within each surgical type, elderly patients had significantly elevated CCI scores. Length of stay was significantly prolonged in elderly patients undergoing partial nephrectomy or prostatectomy. In elderly cystectomy, partial nephrectomy and prostatectomy patients, 36.7%, 14.3% and 5.9% suffered ≥ 1 Clavien grade 3-5 complication, respectively. Major complications were not significantly different between age groups. A qualitatively similar pattern was observed regarding Clavien grade 1-2 complications. The risks of robotic-assisted urologic surgery in elderly patients are not significantly elevated compared to younger patients.

  11. Assessing User Needs and Requirements for Assistive Robots at Home.

    PubMed

    Werner, Katharina; Werner, Franz

    2015-01-01

    'Robots in healthcare' is a very trending topic. This paper gives an overview of currently and commonly used methods to gather user needs and requirements in research projects in the field of assistive robotics. Common strategies between authors are presented as well as examples of exceptions, which can help future researchers to find methods suitable for their own work. Typical problems of the field are discussed and partial solutions are proposed.

  12. Transperitoneal versus extraperitoneal robotic-assisted radical prostatectomy: which one?

    PubMed

    Atug, F; Thomas, R

    2007-06-01

    As robotic surgery has proliferated, both in its availability as well as in its popularity, there are certainly several unresolved matters in the burgeoning field of robotic radical prostatectomy. Matters that are commonly discussed at forums relating to robotic prostatectomy include training, proctoring, overcoming the learning curve, positive surgical margins, quality of life issues, etc. Among the approaches available for robotic radical prostatectomy are the trans-peritoneal (TP) and the extraperitoneal (EP) approaches. Although use of the TP approach vastly outnumbers the EP approach by a wide margin, one must not discount the need for learning the EP approach, especially in patients who could greatly benefit from this approach. The obese, those who have had intraperitoneal procedures in the past, those with ostomies (colostomy, ileostomy) should be considered candidates for the EP approach. For the beginner, it is recommended that familiarizing oneself with the TP approach may be the quickest way to get proficient with use of the robot and for getting over the learning curve, which varies from surgeon to surgeon. Once comfortable with the TP approach, one should consider the application of the EP access, when indicated. One distinct disadvantage of the EP approach is the limited space available for robotic movements. This is why one would prefer getting experience in the TP before forging into the EP approach. Certainly, adequate balloon dissection of the retroperitoneal space above the bladder is critical, as well as additional dissection with the camera in place. Another criticism of the EP approach is the fact that one may not have enough space or ability to perform a complete pelvic lymph node dissection. However, in experienced hands, one is able to do a very comparable job. Though the TP approach would continue to be the premium approach for robotic and laparoscopic radical prostatectomy, one should familiarize oneself with the EP approach since this can clearly be applied to the patient with the correct indication.

  13. General surgery training and robotics: Are residents improving their skills?

    PubMed

    Finnerty, Brendan M; Afaneh, Cheguevara; Aronova, Anna; Fahey, Thomas J; Zarnegar, Rasa

    2016-02-01

    While robotic-assisted operations have become more prevalent, many general surgery residencies do not have a formal robotic training curriculum. We sought to ascertain how well current general surgery training permits acquisition of robotic skills by comparing robotic simulation performance across various training levels. Thirty-six participants were categorized by level of surgical training: eight medical students (MS), ten junior residents (JR), ten mid-level residents (MLR), and eight senior residents (SR). Participants performed three simulation tasks on the da Vinci (®) Skills Simulator (MatchBoard, EnergyDissection, SutureSponge). Each task's scores (0-100) and cumulative scores (0-300) were compared between groups. There were no differences in sex, hand dominance, video gaming history, or prior robotic experience between groups; however, SR was the oldest (p < 0.001). The median overall scores did not differ: 188 (84-201) for MS, 183 (91-234) for JR, 197 (153-218) for MLR, and 205 (169-229) for SR (p = 0.14). The median SutureSponge score was highest for SR (61, range 39-81) compared to MS (43, range 26-61), JR (43, range 11-72), and MLR (55, range 36-68) (p = 0.039). However, there were no significant differences in MatchBoard (p = 0.27) or EnergyDissection (p = 0.99) scores between groups. There was a positive correlation between SutureSponge score and number of laparoscopic cases logged (p = 0.005, r(2) = 0.21), but this correlation did not exist for the MatchBoard or EnergyDissection tasks. Lastly, there was no correlation between total lifetime hours of video gaming and overall score (p = 0.89, R(2) = 0.0006). Robotic skillsets acquired during general surgery residency show minimal improvement during the course of training, although laparoscopic experience is correlated with advanced robotic task performance. Changes in residency curricula or pursuit of fellowship training may be warranted for surgeons seeking proficiency.

  14. Full High-definition three-dimensional gynaecological laparoscopy--clinical assessment of a new robot-assisted device.

    PubMed

    Tuschy, Benjamin; Berlit, Sebastian; Brade, Joachim; Sütterlin, Marc; Hornemann, Amadeus

    2014-01-01

    To investigate the clinical assessment of a full high-definition (HD) three-dimensional robot-assisted laparoscopic device in gynaecological surgery. This study included 70 women who underwent gynaecological laparoscopic procedures. Demographic parameters, type and duration of surgery and perioperative complications were analyzed. Fifteen surgeons were postoperatively interviewed regarding their assessment of this new system with a standardized questionnaire. The clinical assessment revealed that three-dimensional full-HD visualisation is comfortable and improves spatial orientation and hand-to-eye coordination. The majority of the surgeons stated they would prefer a three-dimensional system to a conventional two-dimensional device and stated that the robotic camera arm led to more relaxed working conditions. Three-dimensional laparoscopy is feasible, comfortable and well-accepted in daily routine. The three-dimensional visualisation improves surgeons' hand-to-eye coordination, intracorporeal suturing and fine dissection. The combination of full-HD three-dimensional visualisation with the robotic camera arm results in very high image quality and stability.

  15. Practice patterns and outcomes of open and minimally invasive partial nephrectomy since the introduction of robotic partial nephrectomy: results from the nationwide inpatient sample.

    PubMed

    Ghani, Khurshid R; Sukumar, Shyam; Sammon, Jesse D; Rogers, Craig G; Trinh, Quoc-Dien; Menon, Mani

    2014-04-01

    We determined practice patterns and perioperative outcomes of open and minimally invasive partial nephrectomy in the United States since the introduction of a robot-assisted modifier in the Nationwide Inpatient Sample. We identified all patients with nonmetastatic disease treated with open, laparoscopic or robotic partial nephrectomy in the Nationwide Inpatient Sample between October 2008 and December 2010. Utilization rates were assessed by year, patient and hospital characteristics. We evaluated the perioperative outcomes of open vs robotic and open vs laparoscopic partial nephrectomy using binary logistic regression models adjusted for patient and hospital covariates. In a weighted sample of 38,064 partial nephrectomies 66.9%, 23.9% and 9.2% of the procedures were open, robotic and laparoscopic operations, respectively. In 2010 the relative annual increase in open, robotic and laparoscopic partial nephrectomy was 7.9%, 45.4% and 6.1%, respectively. Compared to open partial nephrectomy patients treated with minimally invasive partial nephrectomy were less likely to receive blood transfusion (robotic vs laparoscopic OR 0.56, p <0.001 vs OR 0.68, p = 0.016), postoperative complication (OR 0.63, p <0.001 vs OR 0.78, p <0.009) or prolonged length of stay (OR 0.27 vs OR 0.41, each p <0.001). Only patients who underwent the robotic procedure were less likely to experience an intraoperative complication (robotic vs laparoscopic OR 0.69, p = 0.014 vs OR 0.67, p = 0.069). Excess hospital charges were higher after robotic surgery (OR 1.35, p <0.001). The dissemination of robotic surgery for partial nephrectomy in the United States has been rapid and safe. Compared to open partial nephrectomy the robotic procedure had lower odds than laparoscopic partial nephrectomy for most study outcomes except hospital charges. Robotic partial nephrectomy has now supplanted laparoscopic partial nephrectomy as the most common minimally invasive approach for partial nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Robotic surgery twice performed in the treatment of hilar cholangiocarcinoma with deep jaundice: delayed right hemihepatectomy following the right-hepatic vascular control.

    PubMed

    Zhu, Zhenyu; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Dong, Maosheng; Mu, Peiyuan; Cheng, Di; Che, Honglei; Zhang, Tao; Xu, Xiaoya; Zhou, Ningxin

    2014-10-01

    To explore and find a new method to treat hilar cholangiocarcinoma with deep jaundice assisted by Da Vinci robot. A hilar cholangiocarcinoma patient of type Bismuch-Corlette IIIa was found with deep jaundice (total bilirubin: 635 µmol/L). On the first admission, we performed Da Vinci robotic surgery including drainage of left hepatic duct, dissection of right hepatic vessels (right portal vein and right hepatic artery), and placement of right-hepatic vascular control device. Three weeks later on the second admission when the jaundice disappeared we occluded right-hepatic vascular discontinuously for 6 days and then sustained later. On the third admission after 3 weeks of right-hepatic vascular control, the right hemihepatectomy was performed by Da Vinci robot for the second time. The future liver remnant after the right-hepatic vascular control increased from 35% to 47%. The volume of left lobe increased by 368 mL. When the total bilirubin and liver function were all normal, right hemihepatectomy was performed by Da Vinci robot 10 weeks after the first operation. The removal of atrophic right hepatic lobe with tumor in bile duct was found with no pathologic cancer remaining in the margin. The patient was followed up at our outpatient clinic every 3 months and no tumor recurrence occurs by now (1 y). Under the Da Vinci robotic surgical system, a programmed treatment can be achieved: first, the hepatic vessels were controlled gradually together with biliary drainage, which results in liver's partial atrophy and compensatory hypertrophy in the other part. Then a radical hepatectomy could be achieved. Such programmed hepatectomy provides a new treatment for patients of hilar cholangiocarcinoma with deep jaundice who have the possibility of radical heptolobectomy.

  17. Robotic surgery and hemostatic agents in partial nephrectomy: a high rate of success without vascular clamping.

    PubMed

    Morelli, Luca; Morelli, John; Palmeri, Matteo; D'Isidoro, Cristiano; Kauffmann, Emanuele Federico; Tartaglia, Dario; Caprili, Giovanni; Pisano, Roberta; Guadagni, Simone; Di Franco, Gregorio; Di Candio, Giulio; Mosca, Franco

    2015-09-01

    Robot-assisted partial nephrectomy has been proposed as a technique to overcome technical challenges of laparoscopic partial nephrectomy. We prospectively collected and analyzed data from 31 patients who underwent robotic partial nephrectomy with systematic use of hemostatic agents, between February 2009 and October 2014. Thirty-three renal tumors were treated in 31 patients. There were no conversions to open surgery, intraoperative complications, or blood transfusions. The mean size of the resected tumors was 27 mm (median 20 mm, range 5-40 mm). Twenty-seven of 33 lesions (82%) did not require vascular clamping and therefore were treated in the absence of ischemia. All margins were negative. The high partial nephrectomy success rate without vascular clamping suggests that robotic nephron-sparing surgery with systematic use of hemostatic agents may be a safe, effective method to completely avoid ischemia in the treatment of selected renal masses.

  18. Comparison of surgical performance and short-term clinical outcomes between laparoscopic and robotic surgery in distal gastric cancer.

    PubMed

    Eom, B W; Yoon, H M; Ryu, K W; Lee, J H; Cho, S J; Lee, J Y; Kim, C G; Choi, I J; Lee, J S; Kook, M C; Rhee, J Y; Park, S R; Kim, Y W

    2012-01-01

    The authors aimed to compare the surgical performance and the short-term clinical outcomes of robotic assisted laparoscopic distal gastrectomy (RADG) with laparoscopy-assisted distal gastrectomy (LADG) in distal gastric cancer patients. From April 2009 to August 2010, 62 patients underwent LADG and 30 patients underwent RADG for preoperative stage I distal gastric cancer by one surgeon at the National Cancer Center, Korea. Surgical performance was measured using lymph node (LN) dissection time and number of retrieved LNs, which were viewed as surrogates of technical ease and oncologic quality. In clinicopathologic characteristics, mean age, depth of invasion and stage were significantly different between the LADG and RADG group. Mean dissection time at each LN station was greater in the RADG group, but no significant intergroup difference was found for numbers of retrieved LNs. Furthermore, proximal resection margins were smaller, and hospital costs were higher in the RADG group. In terms of the RADG learning curve, mean LN dissection time was smaller in the late RADG group (n = 15) than in the early RADG group (n = 15) for 4sb/4d, 5, 7-12a stations, but numbers of retrieved LNs per station were similar. With the exception of operating time and cost, the numbers of retrieved LNs and the short-term clinical outcomes of RADG were found to be comparable to those of LADG, despite the surgeon's familiarity with LADG and lack of RADG experience. Further studies are needed to evaluate objectively ergonomic comfort and to quantify the patient benefits conferred by robotic surgery. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Robotic partial nephrectomy for complex renal tumors: surgical technique.

    PubMed

    Rogers, Craig G; Singh, Amar; Blatt, Adam M; Linehan, W Marston; Pinto, Peter A

    2008-03-01

    Laparoscopic partial nephrectomy requires advanced training to accomplish tumor resection and renal reconstruction while minimizing warm ischemia times. Complex renal tumors add an additional challenge to a minimally invasive approach to nephron-sparing surgery. We describe our technique, illustrated with video, of robotic partial nephrectomy for complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance was used to resect 14 tumors in eight patients (mean age: 50.3 yr; range: 30-68 yr). Three patients had hereditary kidney cancer. All patients had complex tumor features, including hilar tumors (n=5), endophytic tumors (n=4), and/or multiple tumors (n=3). Robotic partial nephrectomy procedures were performed successfully without complications. Hilar clamping was used with a mean warm ischemia time of 31 min (range: 24-45 min). Mean blood loss was 230 ml (range: 100-450 ml). Histopathology confirmed clear-cell renal cell carcinoma (n=3), hybrid oncocytic tumor (n=2), chromophobe renal cell carcinoma (n=2), and oncocytoma (n=1). All patients had negative surgical margins. Mean index tumor size was 3.6 cm (range: 2.6-6.4 cm). Mean hospital stay was 2.6 d. At 3-mo follow-up, no patients experienced a statistically significant change in serum creatinine or estimated glomerular filtration rate and there was no evidence of tumor recurrence. Robotic partial nephrectomy is safe and feasible for select patients with complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance may facilitate a minimally invasive, nephron-sparing approach for select patients with complex renal tumors who might otherwise require open surgery or total nephrectomy.

  20. Initial laboratory experience with a novel ultrasound probe for standard and single-port robotic kidney surgery: increasing console surgeon autonomy and minimizing instrument clashing.

    PubMed

    Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H

    2012-06-01

    The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Potassium-titanyl-phosphate laser assisted robotic partial nephrectomy in a porcine model: can robotic assistance optimize the power needed for effective cutting and hemostasis?

    PubMed

    Boris, Ronald S; Eun, Daniel; Bhandari, Akshay; Lyall, Kathryn; Bhandari, Mahendra; Rogers, Craig; Alassi, Osama; Menon, Mani

    2007-01-01

    A potassium-titanyl-phosphate (KTP) laser through robotic endo-wrist instrument has been evaluated as an ablative and hemostatic tool in robotic assisted laparoscopic partial nephrectomy (RALPN). Ten RALPN were performed in five domestic female pigs. The partial nephrectomies were performed with bulldog clamping of the pedicle. Flexible glass fiber carrying 532-nm green light laser was used through a robotic endowrist instrument in two cases. Power usage from 4 to 10 W was tested. The laser probe was explored both as a cutting knife and for hemostasis. The pelvicalyceal system was closed with a running suture. Partial nephrectomies using KTP laser were performed without complications. Mean operative times and warm ischemia times for laser cases were 96 and 18 min, respectively. Mean estimated blood loss was 60 ml compared with 50 ml for non-laser cases. Complete hemostasis with the laser alone could be achieved with a power of 4 W and was found to be effective. In our hands the laser fiber powered up to 10 W was not effective as a quick cutting agent. Histopathologic analysis of the renal remnant revealed a cauterized surface effect with average laser penetration depth less than 1 mm and minimal surrounding cellular injury. The new robotic endowrist instrument carrying flexible glass fiber transmitting 532-nm green light laser is a useful addition to the armamentarium of the robotic urologic setup. Its control by the console surgeon enables quicker and more complete hemostasis of the cut surface in renal sparing surgery using a porcine model. Histologically proven lased depth of less than 1 mm suggests minimal parenchyma damage in an acute setting. Laser application as a cutting agent, however, requires further investigation with interval power settings beyond the limits of this preliminary study. We estimate that effective cutting should be possible with a setting lower than traditionally recommended for solid organs.

  2. Robot-assisted posterior retroperitoneoscopic adrenalectomy using single-port access: technical feasibility and preliminary results.

    PubMed

    Park, Jae Hyun; Kim, Soo Young; Lee, Cho-Rok; Park, Seulkee; Jeong, Jun Soo; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Chung, Woong Youn; Park, Cheong Soo

    2013-08-01

    Posterior retroperitoneoscopic adrenalectomy (PRA) has several benefits compared with transperitoneal adrenalectomy in that it is safe and has a short learning curve. In addition, it provides direct short access to the target organ, prevents irritation to the intraperitoneal space, and does not require retraction of adjacent organs.1 (-) 3 We have performed several cases of robot-assisted PRA using single-port access for small adrenal tumors. This multimedia article introduces the detailed methods and preliminary results of this procedure. Five patients underwent single-port robot-assisted PRA between March 2010 and June 2011 at our institution. During the procedure, patients were placed in a prone jackknife position with their hip joints bent at a right angle (Fig. 1). A 3 cm transverse skin incision was made just below the lowest tip of the 12th rib (Fig. 2), and the Glove port (Nelis, Kyung-gi, Korea) was placed through the skin incision while maintaining pneumoretroperitoneum (Fig. 3). CO2 was then insufflated to a pressure of 18 mm Hg to create an adequate working space. A 10 mm robotic camera with a 30-degree up view was placed at the center of the incision through the most cephalic portion of the Glove port. A Maryland dissector or Prograsp forceps (Intuitive Surgical, Inc., Sunnyvale, CA) was placed on the medial side of the incision, and Harmonic curved shears (Intuitive Surgical) were placed on the lateral side of the incision (Fig. 4). Using the Maryland dissector and the harmonic curved shears, the Gerota fascia is opened, perinephric fat is dissected, and the kidney upper pole is mobilized to expose the adrenal gland (Fig. 5). Gland dissection starts with lower margin detachment from the upper kidney pole in a lateral to medial direction (Fig. 6). After dissecting the adrenal gland from surrounding adipose tissue and medial isolation of the adrenal central vein, the vessel is ligated with a 5 mm hemolock clip (Fig. 7). Patient clinicopathologic data were analyzed retrospectively. The mean patient age was 56.6 ± 8.7 (range, 47-69) years. Right and left side approaches were used in two and three patients, respectively. All cases were adrenal cortical adenoma. The mean tumor size was 1.48 ± 0.28 (range, 1.0-1.7) cm. The mean surgery duration (skin to skin) was 159.4 ± 57.6 (range, 103-245) minutes, and the mean estimated blood loss was 46.0 ± 56.8 (range, 5-120) ml. The average time to oral intake and postoperative hospital stay were 0.65 ± 0.11 (range, 0.54-0.79) days and 4.0 ± 2.23 (range, 3-8) days, respectively. There were no conversions to open surgery or postoperative compli- cations. Some trials of minimally invasive single-access surgery of the adrenal gland have recently been performed.4 (,) 5 However, these new techniques have several limitations as a result of restrictions on instrumentation movement because of the small access ports used and relatively low-quality images produced. The recent introduction of the da Vinci S surgical robot system (Intuitive Surgical) to endoscopic surgery has improved instrumental dexterity and provided the surgeon with an ergonomically designed operating system. This system is also potentially safer and more meticulous in performing operations than endoscopic procedures as a result of a 3-D, magnified, stable operative view.6 (,) 7 The advantages of the da Vinci S surgical robot system and the numerous benefits of the posterior retroperitoneal approach motivated us to utilize single-port robot-assisted PRA. The primary selection criteria were small tumor size and a minimal amount of periadrenal fatty tissue because robot-assisted PRA using single-port access provides a small operative space, which causes manipulation problems when tumors are large. To ensure the safe application of these new techniques, we recommend that novice surgeons begin using single-port robot-assisted PRA for smaller tumors < 2 cm in patients with a body mass index of < 30 kg/m(2), gradually extending the size and body mass index as they accumulate experience. Although robot-assisted PRA using single-port access could not be compared with the other robotic adrenalectomy techniques in this study, the potential advantages of this approach compared to conventional robot-assisted transperitoneal adrenalectomy include a reduction in postoperative ileus, bacterial contamination, and intestinal complications because the peritoneal cavity is not opened, in addition to a reduction in postoperative pain because of its minimally invasive nature. Our initial experiences with robot-assisted PRA using single-port access assured us of its safety and feasibility for the resection of small adrenal tumors. Although single-port robot-assisted PRA appears to be safe and feasible, further experience and research is required to optimize patient selection criteria and verify its advantages over the traditional three-incision PRA technique.

  3. Anatomic renal artery branch microdissection to facilitate zero-ischemia partial nephrectomy.

    PubMed

    Ng, Casey K; Gill, Inderbir S; Patil, Mukul B; Hung, Andrew J; Berger, Andre K; de Castro Abreu, Andre Luis; Nakamoto, Masahiko; Eisenberg, Manuel S; Ukimura, Osamu; Thangathurai, Duraiyah; Aron, Monish; Desai, Mihir M

    2012-01-01

    Robot-assisted and laparoscopic partial nephrectomies (PNs) for medial tumors are technically challenging even with the hilum clamped and, until now, were impossible to perform with the hilum unclamped. Evaluate whether targeted vascular microdissection (VMD) of renal artery branches allows zero-ischemia PN to be performed even for challenging medial tumors. A prospective cohort evaluation of 44 patients with renal masses who underwent robot-assisted or laparoscopic zero-ischemia PN either with anatomic VMD (group 1; n=22) or without anatomic VMD (group 2; n=22) performed by a single surgeon from April 2010 to January 2011. Zero-ischemia PN with VMD incorporates four maneuvers: (1) preoperative computed tomographic reconstruction of renal arterial branch anatomy, (2) anatomic dissection of targeted, tumor-specific tertiary or higher-order renal arterial branches, (3) neurosurgical aneurysm microsurgical bulldog clamp(s) for superselective tumor devascularization, and (4) transient, controlled reduction of blood pressure, if necessary. Baseline, perioperative, and postoperative data were collected prospectively. Group 1 tumors were larger (4.3 vs 2.6 cm; p=0.011), were more often hilar (41% vs 9%; p=0.09), were medial (59% and 23%; p=0.017), were closer to the hilum (1.46 vs 3.26 cm; p=0.0002), and had a lower C index score (2.1 vs 3.9; p=0.004) and higher RENAL nephrometry scores (7.7 vs 6.2; p=0.013). Despite greater complexity, no group 1 tumor required hilar clamping, and perioperative outcomes were similar to those of group 2: operating room time (4.7 and 4.1h), median blood loss (200 and 100ml), surgical margins for cancer (all negative), major complications (0% and 9%), and minor complications (18% and 14%). The median serum creatinine level was similar 2 mo postoperatively (1.2 and 1.3mg/dl). The study was limited by the relatively small sample size. Anatomic targeted dissection and superselective control of tumor-specific renal arterial branches facilitate zero-ischemia PN. Even challenging medial and hilar tumors can be excised without hilar clamping. Global surgical renal ischemia has been eliminated for most patients undergoing PN at our institution. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  4. Robot-assisted partial nephrectomy vs laparoscopic cryoablation for the small renal mass: redefining the minimally invasive 'gold standard'.

    PubMed

    Emara, Amr M; Kommu, Sashi S; Hindley, Richard G; Barber, Neil J

    2014-01-01

    To identify differences between the ablative and extirpative minimally invasive techniques of laparoscopic cryoablation (LC) and robot-assisted laparoscopic partial nephrectomy (RPN), respectively, in treating small renal tumours in terms of safety, peri-operative morbidity and early oncological outcomes. Between June 2008 and April 2012 56 patients underwent LC and from October 2010 to April 2012, 47 patients underwent RPN using the Da Vinci robotic platform (Intuitive Surgical, Sunnyvale, CA, USA). Data on intra-operative, postoperative and oncological outcomes were collected prospectively, and were analysed and compared for both groups. The median patient ages were 69 and 60 for the LC and RPN groups, respectively (P < 0.05). There was no significant difference in disease stage, but there was a significant difference in tumour size, with patients in the RPN group having larger tumours. The mean operating times were 146 and 159 min for the LC and RPN groups, respectively (P = 0.094) and the mean blood loss was 47 and 94 mL for the LC and the RPN groups, respectively (P = 0.251). The median length of hospital stay (1 day) was the same for both groups and the mean warm ischaemia time was 23 min in the RPN group. The marginal change in preoperative and 6-week postoperative renal function was recorded: the mean postoperative increase in serum creatinine was 5.4 mmol/L in the LC group and 9.2 mmol/L in the RPN group. Of the 47 patients in the RPN group, two (4.3%) were converted to laparoscopic radical nephrectomy because of difficulty in controlling bleeding during hilar dissection. Only two patients (3.6%) had recurrence in the LC group, both of whom were treated with re-cryoablation. A total of 5.4% of patients in the LC and 4.3% in the RPN group had Clavien grade I postoperative complications, one patient in the LC group had a Clavien grade II complication, while 1.8 and 4.3% of patients had Clavien IIIb in the LC and RPN groups, respectively. Our data confirm that LC is a successful, minimally invasive and safe treatment option for the management of small renal tumours, but the apparently similar characteristics of RPN suggest that an increasing proportion of patients, whatever their age or medical comorbidities, may be reasonably offered a robot-assisted extirpative procedure with the likely benefit of lower risk of local recurrence and need for retreatment. © 2013 The Authors. BJU International © 2013 BJU International.

  5. Video. Natural Orifice Translumenal Endoscopic Surgery with a miniature in vivo surgical robot.

    PubMed

    Lehman, Amy C; Dumpert, Jason; Wood, Nathan A; Visty, Abigail Q; Farritor, Shane M; Varnell, Brandon; Oleynikov, Dmitry

    2009-07-01

    The application of flexible endoscopy tools for Natural Orifice Translumenal Endoscopic Surgery (NOTES) is constrained due to limitations in dexterity, instrument insertion, navigation, visualization, and retraction. Miniature endolumenal robots can mitigate these constraints by providing a stable platform for visualization and dexterous manipulation. This video demonstrates the feasibility of using an endolumenal miniature robot to improve vision and to apply off-axis forces for task assistance in NOTES procedures. A two-armed miniature in vivo robot has been developed for NOTES. The robot is remotely controlled, has on-board cameras for guidance, and grasper and cautery end effectors for manipulation. Two basic configurations of the robot allow for flexibility during insertion and rigidity for visualization and tissue manipulation. Embedded magnets in the body of the robot and in an exterior surgical console are used for attaching the robot to the interior abdominal wall. This enables the surgeon to arbitrarily position the robot throughout a procedure. The visualization and task assistance capabilities of the miniature robot were demonstrated in a nonsurvivable NOTES procedure in a porcine model. An endoscope was used to create a transgastric incision and advance an overtube into the peritoneal cavity. The robot was then inserted through the overtube and into the peritoneal cavity using an endoscope. The surgeon successfully used the robot to explore the peritoneum and perform small-bowel dissection. This study has demonstrated the feasibility of inserting an endolumenal robot per os. Once deployed, the robot provided visualization and dexterous capabilities from multiple orientations. Further miniaturization and increased dexterity will enhance future capabilities.

  6. Robotics in percutaneous cardiovascular interventions.

    PubMed

    Pourdjabbar, Ali; Ang, Lawrence; Behnamfar, Omid; Patel, Mitul P; Reeves, Ryan R; Campbell, Paul T; Madder, Ryan D; Mahmud, Ehtisham

    2017-11-01

    The fundamental technique of performing percutaneous cardiovascular (CV) interventions has remained unchanged and requires operators to wear heavy lead aprons to minimize exposure to ionizing radiation. Robotic technology is now being utilized in interventional cardiology partially as a direct result of the increasing appreciation of the long-term occupational hazards of the field. This review was undertaken to report the clinical outcomes of percutaneous robotic coronary and peripheral vascular interventions. Areas covered: A systematic literature review of percutaneous robotic CV interventions was undertaken. The safety and feasibility of percutaneous robotically-assisted CV interventions has been validated in simple to complex coronary disease, and iliofemoral disease. Studies have shown that robotically-assisted PCI significantly reduces operator exposure to harmful ionizing radiation without compromising procedural success or clinical efficacy. In addition to the operator benefits, robotically-assisted intervention has the potential for patient advantages by allowing more accurate lesion length measurement, precise stent placement and lower patient radiation exposure. However, further investigation is required to fully elucidate these potential benefits. Expert commentary: Incremental improvement in robotic technology and telecommunications would enable treatment of an even broader patient population, and potentially provide remote robotic PCI.

  7. Systematic review of perioperative outcomes and complications after open, laparoscopic and robot-assisted radical cystectomy.

    PubMed

    Palazzetti, A; Sanchez-Salas, R; Capogrosso, P; Barret, E; Cathala, N; Mombet, A; Prapotnich, D; Galiano, M; Rozet, F; Cathelineau, X

    2017-09-01

    Radical cystectomy and regional lymph node dissection is the standard treatment for localized muscle-invasive and for high-risk non-muscle-invasive bladder cancer, and represents one of the main surgical urologic procedures. The open surgical approach is still widely adopted, even if in the last two decades efforts have been made in order to evaluate if minimally invasive procedures, either laparoscopic or robot-assisted, might show a benefit compared to the standard technique. Open radical cystectomy is associated with a high complication rate, but data from the laparoscopic and robotic surgical series failed to demonstrate a clear reduction in post-operative complication rates compared to the open surgical series. Laparoscopic and robotic radical cystectomy show a reduction in blood loss, in-hospital stay and transfusion rates but a longer operative time, while open radical cystectomy is typically associated with a shorter operative time but with a longer in-hospital admission and possibly a higher rate of high grade complications. Copyright © 2016. Publicado por Elsevier España, S.L.U.

  8. The impact of marketing language on patient preference for robot-assisted surgery.

    PubMed

    Dixon, Peter R; Grant, Robert C; Urbach, David R

    2015-02-01

    Robot-assisted surgery is gaining momentum as a new trend in minimally invasive surgery. With limited evidence supporting its use in place of the far less expensive conventional laparoscopic surgery, it has been suggested that marketing pressure is partly responsible for its widespread adoption. The impact of phrases that promote the novelty of robot-assisted surgery on patient decision making has not been investigated. We conducted a discrete choice experiment to elicit preference of partial colectomy technique for a hypothetical diagnosis of colon cancer. A convenience sample of 38 participants in an ambulatory general surgery clinic consented to participate. Each participant made 2 treatment decisions between robot-assisted surgery and conventional laparoscopic surgery, with robot-assisted surgery described as "innovative" and "state-of-the-art" in one of the decisions (marketing frame), and by a disclosure of the uncertainty of available evidence in the other (evidence-based frame). The magnitude of the framing effect was large with 12 of 38 subjects (31.6%, P = .005) selecting robot-assisted surgery in the marketing frame and not the evidence-based frame. This is the first study to our knowledge to demonstrate that words that highlight novelty have an important influence on patient preference for robot-assisted surgery and that use of more neutral language can mitigate this effect. © The Author(s) 2014.

  9. The role of intraoperative ultrasound in small renal mass robotic enucleation.

    PubMed

    Gunelli, Roberta; Fiori, Massimo; Salaris, Cristiano; Salomone, Umberto; Urbinati, Marco; Vici, Alexia; Zenico, Teo; Bertocco, Mauro

    2016-12-30

    As a result of the growing evidence on tumor radical resection in literature, simple enucleation has become one of the best techniques associated to robotic surgery in the treatment of renal neoplasia, as it guarantees minimal invasiveness and the maximum sparing of renal tissue, facilitating the use of reduced or zero ischemia techniques during resection. The use of a robotic ultrasound probe represents a useful tool to detect and define tumor location, especially in poorly exophytic small renal mass. A total of 22 robotic enucleations were performed on < 3 cm renal neoplasias (PADUA score 18 Pz 6/7 e 4 Pz 8) using a 12-5 MHz robotic ultrasound probe (BK Drop-In 8826). Once kidney had been isolated from the adipose capsule at the site of the neoplasia (2), the exact position of the lesion could be easily identified in all cases (22/22), even for mostly endophytic lesions, thanks to the insertion of the ultrasound probe through the assistant port. Images were produced and visualized by the surgeon using the TilePro feature of the DaVinci surgical system for producing a picture-in-picture image on the console screen. The margins of resection were then marked with cautery, thus allowing for speedy anatomical dissection. This reduced the time of ischemia to 8 min (6-13) and facilitated the enucleation technique when performed without clamping the renal peduncle (6/22). No complications due to the use of the ultrasound probe were observed. The use of an intraoperative robotic ultrasound probe has allowed for easier identification of small, mostly endophytic neoplasias, better anatomical approach, shorter ischemic time, reduced risk of pseudocapsule rupture during dissection, and easier enucleation in cases performed without clamping. It is noteworthy that the use of intraoperative ultrasound probe allows mental reconstruction of the tumor through an accurate 3D vision of the hidden field during surgical dissection.

  10. The financial impact of robotic technology for partial and radical nephrectomy.

    PubMed

    Kates, Max; Ball, Mark W; Patel, Hiten D; Gorin, Michael A; Pierorazio, Phillip M; Allaf, Mohamad E

    2015-03-01

    We sought to evaluate the financial impact of robotic technology for partial nephrectomy (PN) and radical nephrectomy (RN) in the state of Maryland. The Maryland Health Services Cost Review Commission (HSCRC) documents all acute care hospital charges data. This database was queried for patients who underwent laparoscopic or robot-assisted RN and PN from 2008 to 2012. Total hospital charge, subcharge, and length of stay (LOS) were analyzed separately for RN and PN. Overall, 2834 patients were identified. Of those, 282 were laparoscopic PN (LPN), 1078 robot-assisted PN (RPN), 1098 laparoscopic RN (LRN), and 376 robot-assisted RN (RRN). For PN, the total hospital charge was $19,062 for LPN and $18,255 for RPN (P=0.138), with a charge savings of $807 per case in favor of robotics. For RN, the total hospital charge was $23,391 for RRN and $18,280 for LRN (P=0.004), with a charge premium of $5111 for robotic cases. LOS was shorter for RPN compared with LPN (2.51 vs 2.99 days, P<0.0001) and for RRN compared with LRN (3.52 vs 3.98, P=0.0498). RPN is associated with lower hospital charges than LPN, while RRN is associated with higher hospital charges than LRN. Savings for RPN are driven by decreased room and board charge, while the premium for RRN is driven by higher operating room and supply charges. Because RRN use is increasing, the financial implications of RRN use for routine cases warrants further study.

  11. Effect of Caregiver Driven Robot-Assisted In-Ward Training in Subacute Stroke Patients: A Case Series

    PubMed Central

    2018-01-01

    Objective To evaluate the effect of caregiver driven robot-assisted in-ward training in subacute stroke patients. Methods A retrospective evaluation was performed for patients treated with caregiver driven robot-assisted in-ward training to retain gait function from June 2014 and December 2016. All patients received more than 2 weeks of caregiver driven robot-assisted in-ward training after undergoing conventional programs. The robot was used as a sitting device, a standing frame, or a high-walker depending on functional status of the patient. Patients were evaluated before and after robot training. Patient records were assessed by Korean version of Modified Barthel Index (K-MBI), Functional Independence Measure (FIM), and Functional Ambulation Category (FAC). Results Initially, patients used the robot as a sitting device (n=6), a standing frame (n=7), or a partial body-weight support high-walker (n=2). As patient functions were improved, usage level of the robot was changed to the next level. At the end of the treatment, the robot was used as a sitting device (n=1), a standing frame (n=6), or high-walker (n=8). Scores of K-MBI (Δ17.47±10.72) and FIM (Δ19.80±12.34) were improved in all patients. Conclusion Patients' usage level of the robot and functional scores were improved. Therefore, performing additional caregiver driven robot-assisted in-ward training is feasible and beneficial for subacute stroke patients. PMID:29765872

  12. Effect of Caregiver Driven Robot-Assisted In-Ward Training in Subacute Stroke Patients: A Case Series.

    PubMed

    Kim, Sang Beom; Lee, Kyeong Woo; Lee, Jong Hwa; Lee, Sook Joung; Park, Jin Gee; Park, Joo Won

    2018-04-01

    To evaluate the effect of caregiver driven robot-assisted in-ward training in subacute stroke patients. A retrospective evaluation was performed for patients treated with caregiver driven robot-assisted in-ward training to retain gait function from June 2014 and December 2016. All patients received more than 2 weeks of caregiver driven robot-assisted in-ward training after undergoing conventional programs. The robot was used as a sitting device, a standing frame, or a high-walker depending on functional status of the patient. Patients were evaluated before and after robot training. Patient records were assessed by Korean version of Modified Barthel Index (K-MBI), Functional Independence Measure (FIM), and Functional Ambulation Category (FAC). Initially, patients used the robot as a sitting device (n=6), a standing frame (n=7), or a partial body-weight support high-walker (n=2). As patient functions were improved, usage level of the robot was changed to the next level. At the end of the treatment, the robot was used as a sitting device (n=1), a standing frame (n=6), or high-walker (n=8). Scores of K-MBI (Δ17.47±10.72) and FIM (Δ19.80±12.34) were improved in all patients. Patients' usage level of the robot and functional scores were improved. Therefore, performing additional caregiver driven robot-assisted in-ward training is feasible and beneficial for subacute stroke patients.

  13. Robotics in endoscopy.

    PubMed

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  14. The robotic Whipple: operative strategy and technical considerations.

    PubMed

    MacKenzie, Shawn; Kosari, Kambiz; Sielaff, Timothy; Johnson, Eric

    2011-03-01

    Advances in robotic surgery have allowed the frontiers of minimally invasive pancreatic surgery to expand. We present a step-by-step approach to the robotic Whipple procedure. The discussion includes port setting and robotic docking, kocherization and superior mesenteric vein identification, portal dissection, releasing the ligament of Treitz, uncinate dissection, and reconstruction. A brief report of our initial 2-year experience with the robotic Whipple procedure is also presented.

  15. Robotic hepatobiliary surgery: update on the current status.

    PubMed

    Carr, A D; Ali, M R; Khatri, V P

    2013-10-01

    An update on the current status of robotic hepatobiliary surgery based on a review of the available literature. A literature search was performed using the PubMed database with search phrases "robotic hepatectomy", "robotic liver resection", "robotic liver surgery", "robotic hepatobiliary surgery", and "robotic biliary reconstruction". We selected articles with high volume case series or case controlled series. As a result of our literature search we will focus on the 9 major articles on robotic liver resection (RLR) with 235 patients undergoing RLR for a total of 244 liver resections. In addition a brief update on robotic biliary reconstruction will also be presented based on the above articles and recent review articles. Indications for robotic liver resection included both benign (N.=72, 29.5%) and malignant disease (N.=172, 70.5%). The most common indication was colorectal liver metastasis (N.=87, 50.6%) and hepatocellular carcinoma (N.=57, 33%). The most common type of resection was subsegmental (N.=55, 22.5%), with a significant number of major hepatectomies (N.=80, 32.8%). Overall conversion rate was 7.8%, with majority converted to open (N.=18) and one converted to hand assisted. The overall complication rate was 11.8% (N.=29). No perioperative mortality was reported. Preliminary results show that robotic assisted laparoscopic hepatobiliary surgery has materialized as a new technique that combines the advantages of laparoscopy with the dissection, suturing and articulation of robotics. This more closely approximates open surgery. The preliminary data demonstrates that RLR can be applied in major hepatobiliary centers safely. Future comparative studies are needed to determine if this is of significant benefit over current open techniques.

  16. Mixed reality for robotic treatment of a splenic artery aneurysm.

    PubMed

    Pietrabissa, Andrea; Morelli, Luca; Ferrari, Mauro; Peri, Andrea; Ferrari, Vincenzo; Moglia, Andrea; Pugliese, Luigi; Guarracino, Fabio; Mosca, Franco

    2010-05-01

    Techniques of mixed reality can successfully be used in preoperative planning of laparoscopic and robotic procedures and to guide surgical dissection and enhance its accuracy. A computer-generated three-dimensional (3D) model of the vascular anatomy of the spleen was obtained from the computed tomography (CT) dataset of a patient with a 3-cm splenic artery aneurysm. Using an environmental infrared localizer and a stereoscopic helmet, the surgeon can see the patient's anatomy in transparency (augmented or mixed reality). This arrangement simplifies correct positioning of trocars and locates surgical dissection directly on top of the aneurysm. In this way the surgeon limits unnecessary dissection, leaving intact the blood supply from the short gastric vessels and other collaterals. Based on preoperative planning, we were able to anticipate that the vascular exclusion of the aneurysm would result in partial splenic ischemia. To re-establish the flow to the spleen, end-to-end robotic anastomosis of the splenic artery with the Da Vinci surgical system was then performed. Finally, the aneurysm was fenestrated to exclude arterial refilling. The postoperative course was uneventful. A control CT scan 4 weeks after surgery showed a well-perfused and homogeneous splenic parenchyma. The final 3D model showed the fenestrated calcified aneurysm and patency of the re-anastomosed splenic artery. The described technique of robotic vascular exclusion of a splenic artery aneurysm, followed by re-anastomosis of the vessel, clearly demonstrates how this technology can reduce the invasiveness of the procedure, obviating an otherwise necessary splenectomy. Also, the use of intraoperative mixed-reality technology proved very useful in this case and is expected to play an increasing role in the operating room of the future.

  17. Laser robotically assisted nerve-sparing radical prostatectomy: a pilot study of technical feasibility in the canine model.

    PubMed

    Gianduzzo, Troy; Colombo, Jose R; Haber, Georges-Pascal; Hafron, Jason; Magi-Galluzzi, Cristina; Aron, Monish; Gill, Inderbir S; Kaouk, Jihad H

    2008-08-05

    To examine the feasibility of using laser energy during nerve-sparing robotically assisted radical prostatectomy (RARP), as the energy sources currently used for haemostasis in RARP adversely affect cavernous nerve function, while clips require application by a skilled assistant, but laser energy potentially allows precise dissection with minimal collateral tissue injury. We used laser-based RARP in 10 dogs, using the da Vinci S system (Intuitive Surgical, Sunnyvale, CA, USA) and a prototype robotic laser instrument. The potassium-titanyl-phosphate laser was used for dissection at 2-6 W, with intermittent use of the neodymium-doped yttrium-aluminium-garnet laser at 5 W for coagulating larger vessels. The peak intracavernosal pressure response to nerve stimulation was recorded as a percentage of mean arterial pressure (ICP%MAP) before and after RARP. Five dogs were killed immediately after RARP and five were maintained alive for 72 h; the haemoglobin and haematocrit levels were measured before and after RARP in the latter five dogs. All 10 procedures were performed solely using laser energy and no additional haemostatic manoeuvres. The median prostate excision time was 65 min. The ICP%MAP before and after RARP (median 98.5% and 77.0%, P = 0.12) were not significantly different; similarly, the respective haemoglobin (median 14.4 vs 12.6 g/dL, P = 0.06) and haematocrit levels (45.1% vs 40.2%, P = 0.06) were not significantly different. Two dogs had catheter-related complications and one had an anastomotic leak. There were no laser-related complications or postoperative haemorrhage. Laser RARP is feasible in dogs and further assessment is warranted.

  18. Insight into the da Vinci® Xi - technical notes for single-docking left-sided colorectal procedures.

    PubMed

    Ngu, James Chi-Yong; Sim, Sarah; Yusof, Sulaiman; Ng, Chee-Yung; Wong, Andrew Siang-Yih

    2017-12-01

    The adoption of robot-assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi-quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left-sided colorectal procedures. Our initial series of left-sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Between March 2015 and April 2016, 54 cases of robot-assisted laparoscopic left-sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi-quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. The da Vinci® Xi simplifies the docking procedure and makes single-docking feasible for multi-quadrant left-sided colorectal procedures. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Preoperative fiducial coil placement facilitates robot-assisted laparoscopic excision of retroperitoneal small solitary metastasis of kidney cancer.

    PubMed

    Agrawal, Vineet; Sharma, Ashwani; Wu, Guan

    2014-11-01

    Image-guided fiducial markers are being used in surgery, especially in spine and breast surgery, and radiotherapy, allowing localization of tumor sites precisely. We report a case of fiducial coil use in a man undergoing a robot-assisted laparoscopic resection of a metastatic nodule under the ipsilateral diaphragm after robot-assisted partial nephrectomy performed 2 years ago for a left upper pole renal tumor. The fiducial coil facilitated the localization of the lesion, which would otherwise have been challenging because of its small size and location. In addition, the fiducial coil was helpful to avoid cutting into the lesion directly. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Robotic assisted laparoscopic partial nephrectomy using contrast-enhanced ultrasound scan to map renal blood flow.

    PubMed

    Alenezi, Ahmad; Motiwala, Aamir; Eves, Susannah; Gray, Rob; Thomas, Asha; Meiers, Isabelle; Sharif, Haytham; Motiwala, Hanif; Laniado, Marc; Karim, Omer

    2017-03-01

    The paper describes novel real-time 'in situ mapping' and 'sequential occlusion angiography' to facilitate selective ischaemia robotic partial nephrectomy (RPN) using intraoperative contrast enhanced ultrasound scan (CEUS). Data were collected and assessed for 60 patients (61 tumours) between 2009 and 2013. 31 (50.8%) tumours underwent 'Global Ischaemia', 27 (44.3%) underwent 'Selective Ischaemia' and 3 (4.9%) were removed 'Off Clamp Zero Ischaemia'. Demographics, operative variables, complications, renal pathology and outcomes were assessed. Median PADUA score was 9 (range 7-10). The mean warm ischaemia time in selective ischaemia was less and statistically significant than in global ischaemia (17.1 and 21.4, respectively). Mean operative time was 163 min. Postoperative complications (n = 10) included three (5%) Clavien grade 3 or above. Malignancy was demonstrated in 47 (77%) with negative margin in 43 (91.5%) and positive margin in four (8.5%). Long-term decrease in eGFR post selective ischaemia robotic partial nephrectomy was less compared with global ischaemia (four and eight, respectively) but not statistically significant. This technique is safe, feasible and cost-effective with comparable perioperative outcomes. The technical aspects elucidate the role of intraoperative CEUS to facilitate and ascertain selective ischaemia. Further work is required to demonstrate long-term oncological outcomes. © 2016 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons, Ltd. © 2016 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons, Ltd.

  1. From Leonardo to da Vinci: the history of robot-assisted surgery in urology.

    PubMed

    Yates, David R; Vaessen, Christophe; Roupret, Morgan

    2011-12-01

    What's known on the subject? and What does the study add? Numerous urological procedures can now be performed with robotic assistance. Though not definitely proven to be superior to conventional laparoscopy or traditional open surgery in the setting of a randomised trial, in experienced centres robot-assisted surgery allows for excellent surgical outcomes and is a valuable tool to augment modern surgical practice. Our review highlights the depth of history that underpins the robotic surgical platform we utilise today, whilst also detailing the current place of robot-assisted surgery in urology in 2011. The evolution of robots in general and as platforms to augment surgical practice is an intriguing story that spans cultures, continents and centuries. A timeline from Yan Shi (1023-957 bc), Archytas of Tarentum (400 bc), Aristotle (322 bc), Heron of Alexandria (10-70 ad), Leonardo da Vinci (1495), the Industrial Revolution (1790), 'telepresence' (1950) and to the da Vinci(®) Surgical System (1999), shows the incredible depth of history and development that underpins the modern surgical robot we use to treat our patients. Robot-assisted surgery is now well-established in Urology and although not currently regarded as a 'gold standard' approach for any urological procedure, it is being increasingly used for index operations of the prostate, kidney and bladder. We perceive that robotic evolution will continue infinitely, securing the place of robots in the history of Urological surgery. Herein, we detail the history of robots in general, in surgery and in Urology, highlighting the current place of robot-assisted surgery in radical prostatectomy, partial nephrectomy, pyeloplasty and radical cystectomy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  2. Robotic surgery in complicated gynecologic diseases: experience of Tri-Service General Hospital in Taiwan.

    PubMed

    Tan, Shun-Jen; Lin, Chi-Kung; Fu, Pei-Te; Liu, Yung-Liang; Sun, Cheng-Chian; Chang, Cheng-Chang; Yu, Mu-Hsien; Lai, Hung-Cheng

    2012-03-01

    Minimally invasive surgery has been the trend in various specialties and continues to evolve as new technology develops. The development of robotic surgery in gynecology remains in its infancy. The present study reports the first descriptive series of robotic surgery in complicated gynecologic diseases in Taiwan. From March 2009 to February 2011, the records of patients undergoing robotic surgery using the da Vinci Surgical System were reviewed for patient demographics, indications, operative time, hospital stay, conversion to laparotomy, and complications. Sixty cases were reviewed in the present study. Forty-nine patients had benign gynecologic diseases, and 11 patients had malignancies. These robot-assisted laparoscopic procedures include nine hysterectomy, 15 subtotal hysterectomy, 13 myomectomy, eight staging operation, two radical hysterectomy, five ovarian cystectomy, one bilateral salpingo-oophorectomy and myomectomy, two resections of deep pelvic endometriosis, one pelvic adhesiolysis, three sacrocolpopexy and one tuboplasty. Thirty-three patients had prior pelvic surgery, and one had a history of pelvic radiotherapy. Adhesiolysis was necessary in 38 patients to complete the whole operation. Robotic myomectomy was easily accomplished in patients with huge uterus or multiple myomas. The suturing of myometrium or cervical stump after ligation of the uterine arteries minimized the blood loss. In addition, it was much easier to dissect severe pelvic adhesions. The dissection of para-aortic lymph nodes can be easily accomplished. All these surgeries were performed smoothly without ureteral, bladder or bowel injury. The present analyses include various complicated gynecologic conditions, which make the estimation of the effectiveness of robotic surgery in each situation individually not appropriate. However, our experiences do show that robotic surgery is feasible and safe for patients with complicated gynecologic diseases. Copyright © 2012. Published by Elsevier B.V.

  3. Robotic transthoracic esophagectomy.

    PubMed

    Puntambekar, Shailesh; Kenawadekar, Rahul; Kumar, Sanjay; Joshi, Saurabh; Agarwal, Geetanjali; Reddy, Sunil; Mallik, Jainul

    2015-04-23

    We have initially published our experience with the robotic transthoracic esophagectomy in 32 patients from a single institute. The present paper is the extension of our experience with robotic system and to best of our knowledge this represents the largest series of robotic transthoracic esophagectomy worldwide. The objective of this study was to investigate the feasibility of the robotic transthoracic esophagectomy for esophageal cancer in a series of patients from a single institute. A retrospective review of medical records was conducted for 83 esophageal cancer patients who underwent robotic esophagectomy at our institute from December 2009 to December 2012. All patients underwent a thorough clinical examination and pre-operative investigations. All patients underwent robotic esophageal mobilization. En-bloc dissection with lymphadenectomy was performed in all cases with preservation of Azygous vein. Relevant data were gathered from medical records. The study population comprised of 50 men and 33 women with mean age of 59.18 years. The mean operative time was 204.94 mins (range 180 to 300). The mean blood loss was 86.75 ml (range 50 to 200). The mean number of lymph node yield was 18. 36 (range 13 to 24). None of the patient required conversion. The mean ICU stay and hospital stay was 1 day (range 1 to 3) and 10.37 days (range 10 to 13), respectively. A total of 16 (19.28%) complication were reported in these patents. Commonly reported complication included dysphagia, pleural effusion and anastomotic leak. No treatment related mortality was observed. After a median follow-up period of 10 months, 66 patients (79.52%) survived with disease free stage. We found robot-assisted thoracoscopic esophagectomy feasible in cases of esophageal cancer. The procedure allowed precise en-bloc dissection with lymphadenectomy in mediastinum with reduced operative time, blood loss and complications.

  4. Zero ischemia robotic-assisted partial nephrectomy in Alberta: Initial results of a novel approach.

    PubMed

    Forbes, Ellen; Cheung, Douglas; Kinnaird, Adam; Martin, Blair St

    2015-01-01

    Partial nephrectomy remains the standard of care in early stage, organ-confined renal tumours. Recent evidence suggests that minimally invasive surgery can proceed without segmental vessel clamping. In this study, we review our experience at a Canadian centre with zero ischemia robotic-assisted partial nephrectomy (RAPN). A retrospective chart review of zero ischemia RAPN was performed. All surgeries were consecutive partial nephrectomies performed by the same surgeon at a tertiary care centre in Northern Alberta. The mean follow-up period was 28 months. These outcomes were compared against the current standards for zero ischemia (as outlined by the University of Southern California Institute of Urology [USC]). We included 21 patients who underwent zero ischemia RAPN between January 2012 and June 2013. Baseline data were similar to contemporary studies. Twelve (57.1%) required no vascular clamping, 7 (33.3%) required clamping of a single segmental artery, and 2 (9.5%) required clamping of two segmental arteries. We achieved an average estimated blood loss of 158 cc, with a 9.2% average increase in creatinine postoperatively. Operating time and duration of hospital stay were short at 153 minutes and 2.2 days, respectively. Zero ischemia partial nephrectomy was a viable option at our institution with favourable results in terms of intra-operative blood loss and postoperative creatinine change compared to results from contemporary standard zero ischemia studies (USC). To our knowledge, this is the first study to review an initial experience with the zero ischemia protocol in robotic-assisted partial nephrectomies at a Canadian hospital.

  5. Robot-assisted simple prostatectomy: multi-institutional outcomes for glands larger than 100 grams.

    PubMed

    Vora, Anup; Mittal, Sameer; Hwang, Jonathan; Bandi, Gaurav

    2012-05-01

    To present our experience with robot-assisted simple prostatectomy in patients with large gland adenoma (>100 g) that would not be amenable to transurethral treatments. From August 2009 to May 2011, 13 robot-assisted simple suprapubic prostatectomies were performed in patients with symptomatic large gland (>100 g) prostatomegaly on transrectal ultrasonography (mean 163 cc). Essential aspects of our technique include a transverse cystotomy just proximal to the prostatovesical junction and use of a robotic tenotomy grasper to aid in adenoma dissection. Mean operative time was 179 minutes (range 90-270 min), and mean estimated blood loss was 219 mL (range 50-500 mL). Mean hospital stay was 2.7 days (range 1-8 d), and the mean urethral catheterization time was 8.8 days (range 5-14 d). None of the patients needed blood transfusion. One patient had an intraoperative urinary leak after bladder closure that was managed with prolonged urethral catheterization (14 d). Histopathologic analysis confirmed benign prostatic hyperplasia (BPH) in all patients, and mean specimen weight on pathologic examination was 127 g (range 100-165 g). Mean follow-up duration was 7.2 months with all patients having a minimum of a 4-month follow-up. Significant improvements were noted in the International Prostate Symptom Score (preoperative vs postoperative 18.1 vs 5.3, p<0.001) and the maximum urine flow rate (preoperative vs postoperative 4.3 vs 19.1 mL/min, P<0.001). Minimally invasive robot-assisted simple prostatectomy is technically feasible in patients with large volume (>100 g) BPH and is associated with significant improvements in obstructive urinary symptoms. Surgeons with robotic expertise may consider using this approach for treatment of their patients with large volume BPH.

  6. Robot-assisted radical cystectomy – first Polish clinical outcomes

    PubMed Central

    Juszczak, Kajetan; Poblocki, Pawel; Mikolajczak, Witold; Drewa, Tomasz

    2017-01-01

    Introduction Urothelial cell carcinoma is the most common neoplasm of the genito-urinary tract, which, in advanced stages, is treated with radical cystectomy with pelvic lymphadenectomy. It can be performed by an open or minimally invasive approach (laparoscopic and robot-assisted radical cystectomy). Large meta-analyses showed a significantly lower complication rate in the RARC (robot-assisted radical cystectomy) group compared to ORC (open radical cystectomy) in thirty and ninety days after surgery, with similar oncological and functional outcomes. The clinical outcomes of the first forty Polish RARC are explored in this article. Material and methods The Polish Radical Robotic Cystectomy Program (PRRC) was started in 2016 at the Nicolaus Copernicus Hospital in Toruń. Forty consecutive patients, with indications for cystectomy were included into the study. During radical robot-assisted cystectomy, obturator, external, internal, common iliac and presacral lymph nodes were dissected. Oncological outcomes, early complication rate, and the clinical variables were analyzed. Results The mean age in the study group was sixty-seven years, with the majority of patients being overweight and assessed as American Society of Anesthesiology Scale (ASA) – ASA III and ASA IV (2/3 of patients). RARC was performed, with the median time of surgery being 324 minutes (170 minutes being the shortest). Mean blood loss was 365 ml (lowest – 50 ml), and only 2 patients required intraoperative blood transfusion. Twenty patients had ileal conduit, and nineteen had other methods of urinary diversion. Only twenty-nine out of forty patients had minor complications (Clavien I and II), 11 had Clavien III and IV. Clavien V was not present. Only 3 patients required reoperation. Conclusions RARC is a reproducible oncological procedure, which can be safely performed in centers with robotic expertise, with acceptable operative time, complications, and functional and oncologic outcomes. PMID:29732201

  7. Robotics in general thoracic surgery procedures.

    PubMed

    Latif, M Jawad; Park, Bernard J

    2017-01-01

    The use of robotic technology in general thoracic surgical practice continues to expand across various institutions and at this point many major common thoracic surgical procedures have been successfully performed by general thoracic surgeons using the robotic technology. These procedures include lung resections, excision of mediastinal masses, esophagectomy and reconstruction for malignant and benign esophageal pathologies. The success of robotic technology can be attributed to highly magnified 3-D visualization, dexterity afforded by 7 degrees of freedom that allow difficult dissections in narrow fields and the ease of reproducibility once the initial set up and instruments become familiar to the surgeon. As the application of robotic technology trickle downs from major academic centers to community hospitals, it becomes imperative that its role, limitations, learning curve and financial impact are understood by the novice robotic surgeon. In this article, we share our experience as it relates to the setup, common pitfalls and long term results for more commonly performed robotic assisted lung and thymic resections using the 4 arm da Vinci Xi robotic platform (Intuitive Surgical, Inc., Sunnyvale, CA, USA) to help guide those who are interested in adopting this technology.

  8. Robot-assisted laparoscopic pyeloplasty: minimum 1-year follow-up

    NASA Astrophysics Data System (ADS)

    Patel, Vipul; Thaly, Rahul; Shah, Ketul

    2007-02-01

    Objectives: To evaluate the feasibility and efficacy of robotic-assisted laparoscopic pyeloplasty. Laparoscopic pyeloplasty has been shown to have a success rate comparable to that of the open surgical approach. However, the steep learning curve has hindered its acceptance into mainstream urologic practice. The introduction of robotic assistance provides advantages that have the potential to facilitate precise dissection and intracorporeal suturing. Methods: A total of 50 patients underwent robotic-assisted laparoscopic dismembered pyeloplasty. A four-trocar technique was used. Most patients were discharged home on day 1, with stent removal at 3 weeks. Patency of the ureteropelvic junction was assessed in all patients with mercaptotriglycylglycine Lasix renograms at 1, 3, 6, 9, and 12 months, then every 6 months for 1 year, and then yearly. Results: Each patient underwent a successful procedure without open conversion or transfusion. The average estimated blood loss was 40 ml. The operative time averaged 122 minutes (range 60 to 330) overall. Crossing vessels were present in 30% of the patients and were preserved in all cases. The time for the anastomosis averaged 20 minutes (range 10 to 100). Intraoperatively, no complications occurred. Postoperatively, the average hospital stay was 1.1 days. The stents were removed at an average of 20 days (range 14 to 28) postoperatively. The average follow-up was 11.7 months; at the last follow-up visit, each patient was doing well. Of the 50 patients, 48 underwent one or more renograms, demonstrating stable renal function, improved drainage, and no evidence of recurrent obstruction. Conclusions: Robotic-assisted laparoscopic pyeloplasty is a feasible technique for ureteropelvic junction reconstruction. The procedure provides a minimally invasive alternative with good short-term results.

  9. Robotic kidney autotransplantation in a porcine model: a procedure-specific training platform for the simulation of robotic intracorporeal vascular anastomosis.

    PubMed

    Tiong, Ho Yee; Goh, Benjamin Yen Seow; Chiong, Edmund; Tan, Lincoln Guan Lim; Vathsala, Anatharaman

    2018-03-31

    Robotic-assisted kidney transplantation (RKT) with the Da Vinci (Intuitive, USA) platform has been recently developed to improve outcomes by decreasing surgical site complications and morbidity, especially in obese patients. This potential paradigm shift in the surgical technique of kidney transplantation is performed in only a few centers. For wider adoption of this high stake complex operation, we aimed to develop a procedure-specific simulation platform in a porcine model for the training of robotic intracorporeal vascular anastomosis and evaluating vascular anastomoses patency. This paper describes the requirements and steps developed for the above training purpose. Over a series of four animal ethics' approved experiments, the technique of robotic-assisted laparoscopic autotransplantation of the kidney was developed in Amsterdam live pigs (60-70 kg). The surgery was based around the vascular anastomosis technique described by Menon et al. This non-survival porcine training model is targeted at transplant surgeons with robotic surgery experience. Under general anesthesia, each pig was placed in lateral decubitus position with the placement of one robotic camera port, two robotic 8 mm ports and one assistant port. Robotic docking over the pig posteriorly was performed. The training platform involved the following procedural steps. First, ipsilateral iliac vessel dissection was performed. Second, robotic-assisted laparoscopic donor nephrectomy was performed with in situ perfusion of the kidney with cold Hartmann's solution prior to complete division of the hilar vessels, ureter and kidney mobilization. Thirdly, the kidney was either kept in situ for orthotopic autotransplantation or mobilized to the pelvis and orientated for the vascular anastomosis, which was performed end to end or end to side after vessel loop clamping of the iliac vessels, respectively, using 6/0 Gore-Tex sutures. Following autotransplantation and release of vessel loops, perfusion of the graft was assessed using intraoperative indocyanine green imaging and monitoring urine output after unclamping. This training platform demonstrates adequate face and content validity. With practice, arterial anastomotic time could be improved, showing its construct validity. This porcine training model can be useful in providing training for robotic intracorporeal vascular anastomosis and may facilitate confident translation into a transplant human recipient.

  10. Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique.

    PubMed

    Abel, Taylor J; Varela Osorio, René; Amorim-Leite, Ricardo; Mathieu, Francois; Kahane, Philippe; Minotti, Lorella; Hoffmann, Dominique; Chabardes, Stephan

    2018-04-20

    OBJECTIVE Robot-assisted stereoelectroencephalography (SEEG) is gaining popularity as a technique for localization of the epileptogenic zone (EZ) in children with pharmacoresistant epilepsy. Here, the authors describe their frameless robot-assisted SEEG technique and report preliminary outcomes and relative complications in children as compared to results with the Talairach frame-based SEEG technique. METHODS The authors retrospectively analyzed the results of 19 robot-assisted SEEG electrode implantations in 17 consecutive children (age < 17 years) with pharmacoresistant epilepsy, and compared these results to 19 preceding SEEG electrode implantations in 18 children who underwent the traditional Talairach frame-based SEEG electrode implantation. The primary end points were seizure-freedom rates, operating time, and complication rates. RESULTS Seventeen children (age < 17 years) underwent a total of 19 robot-assisted SEEG electrode implantations. In total, 265 electrodes were implanted. Twelve children went on to have EZ resection: 4 demonstrated Engel class I outcomes, whereas 2 had Engel class II outcomes, and 6 had Engel class III-IV outcomes. Of the 5 patients who did not have resection, 2 underwent thermocoagulation. One child reported transient paresthesia associated with 2 small subdural hematomas, and 3 other children had minor asymptomatic intracranial hemorrhages. There were no differences in complication rates, rates of resective epilepsy surgery, or seizure freedom rates between this cohort and the preceding 18 children who underwent Talairach frame-based SEEG. The frameless robot-assisted technique was associated with shorter operating time (p < 0.05). CONCLUSIONS Frameless robot-assisted SEEG is a safe and effective means of identifying the EZ in children with pharmacoresistant partial epilepsy. Robot-assisted SEEG is faster than the Talairach frame-based method, and has equivalent safety and efficacy. The former, furthermore, facilitates more electrode trajectory possibilities, which may improve the localization of epileptic networks.

  11. Robotic partial nephrectomy with selective parenchymal compression (Simon clamp).

    PubMed

    Castillo, O A; Rodriguez-Carlin, A; Lopez-Fontana, G; Aleman, E

    2013-01-01

    To present our initial experience using selective renal parenchymal ischemia, without hilar clamping, in robotic-assisted partial nephrectomy. In four patients with T1a renal tumor we performed robotic-assisted partial nephrectomy, using the Simon's clamp (Aesculap). It provides selective parenchymal compression without the need of vascular clamping. All patients had exofitic renal tumors in polar location. Renal parenchymal reconstruction was done as the standard technique. The median age was 49.6 years (42-59), 3 male and 1 female patient. Median operative time was 71,6 minutes (40-120). Mean stimated bleeding was 250 ml (50-400). Average tumor size was 3,25 cm (1,5-5,3). There were no complications and the average hospital stay was 3,5 days (1-7). The pathology was informed as renal cell carcinoma in three patients and one hemorrhagic cyst. The surgical margins were negative. Our preliminary results shows that selective renal parenchymal compression, with the Simon's clamp, provides an alternative to vascular control in selected patients with polar renal tumors. Copyright © 2012 AEU. Published by Elsevier Espana. All rights reserved.

  12. The pubovesical complex-sparing technique on laparoscopic radical prostatectomy.

    PubMed

    Rebouças, Rafael Batista; Monteiro, Rodrigo Campos; Lima, João Paulo Pereira; Almeida, Filipe Pádua B F; Britto, Cesar Araujo; Tobias-Machado, Marcos; Passerotti, Carlo

    2018-03-01

    Preservation of urinary continence is a great challenge in Radical Prostatectomy. In order to improve functional results, Asimakopoulos et al. (2010) described a robot-assisted surgical technique with preservation of the pubovesical complex (PVC). We present a pure laparoscopic execution. A 61-year-old male patient with a diagnosis of prostate cancer, with PSA 6.54ng/ml, DRE: T1C and Gleason 6 (3+3) 1/12 fragments. All therapeutic possibilities were discussed, including active surveillance. The patient opted for surgical treatment. A transperitoneal technique was used. We started the dissection on the left side, in the limit between the detrusor and the base of the prostate. The left seminal vesicle was dissected and left neurovascular bundle released by a high anterior dissection. We repeated the same procedure on the right side. The urethra was then divided, prostatic apex was laterally drawn and PVC was released. The bladder neck was divided and an urethrovesical anastomosis was achieved. A pelvic drain was placed. The total operative time was 150 minutes. The estimated blood loss was 300mL. The drain was removed on the 1st postoperative day and the patient was discharged. The Foley catheter was removed after 7 days and the patient remained completely dry. Hystopathology revealed adenocarcinoma Gleason 6, negative margins. PSA after 30 days was <0.04ng/mL, and the patient reported partial penile erection. The Pubovesical Complex-Sparing Technique on Laparoscopic Radical Prostatectomy was feasible and safe. Further adequately designed studies are needed to confirm whether this technique enhances early functional outcomes. Copyright® by the International Brazilian Journal of Urology.

  13. Hand-assisted laparoscopic versus robot-assisted laparoscopic partial nephrectomy: comparison of short-term outcomes and cost.

    PubMed

    Elsamra, Sammy E; Leone, Andrew R; Lasser, Michael S; Thavaseelan, Simone; Golijanin, Dragan; Haleblian, George E; Pareek, Gyan

    2013-02-01

    Robot-assisted laparoscopic partial nephrectomy (RALPN) and laparoscopic partial nephrectomy (LPN) have become standard for the surgical management of small renal masses (SRMs). However, no studies have evaluated the short-term outcomes or cost of RALPN as compared with hand-assisted laparoscopic partial nephrectomy (HALPN) in a standardized fashion. A retrospective review of all patients who underwent HALPN or RALPN from 2006 to 2010 were assessed for patient age, body mass index (BMI), American Society of Anesthesiologists (ASA) score, radiographic tumor size, nephrometry (radius, endo/exophytic, nearness to collecting system, anterior/posterior, lines of polarity [RENAL]) scores, operative and room times, hospital length of stay (LOS), estimated blood loss (EBL), requirement of hilar vessel clamping, warm ischemia time (WIT), pre- and postprocedural creatinine and hemoglobin levels, and complications. Total costs of the procedures were estimated based on operating room component (operative staff time, anesthesia, and supply) and hospital stay cost (room and board, pharmacy). A robotic premium cost, estimated based on the yearly overall cost of the da Vinci S surgical system divided by the annual number of cases, was included in the RALPN cost. Cost figures were obtained from hospital administration and applied to the mean HALPN and RALPN patient. Forty-seven patients underwent HALPN since 2006 and 21 patients underwent RALPN since 2008. ASA, BMI, EBL, tumor size, nephrometry score, positive margin rate, change in creatinine, change in hemoglobin, morphine equivalents used, and complication rate were all similar in both groups (p>0.05). Room time and operative time were significantly shorter for the HALPN cohort (p=0.001) whereas LOS was significantly shorter in the RALPN cohort (p=0.019). Despite the shorter LOS, RALPN was associated with a $1165 increased cost, mainly due to increased operating room time and premium cost of the robot. While early in our experience, RALPN offered no significant advantage in short-term outcomes over HALPN and was associated with an increased cost of over $1150.

  14. Positive surgical margins in robot-assisted partial nephrectomy: a multi-institutional analysis of oncologic outcomes (leave no tumor behind).

    PubMed

    Khalifeh, Ali; Kaouk, Jihad H; Bhayani, Sam; Rogers, Craig; Stifelman, Michael; Tanagho, Youssef S; Kumar, Ramesh; Gorin, Michael A; Sivarajan, Ganesh; Samarasekera, Dinesh; Allaf, Mohamad E

    2013-11-01

    Expanding indications for robot-assisted partial nephrectomy raise major oncologic concerns for positive surgical margins. Previous reports showed no correlation between positive surgical margins and oncologic outcomes. We report a multi-institutional experience with the oncologic outcomes of positive surgical margins on robot-assisted partial nephrectomy. Pathological and clinical followup data were reviewed from an institutional review board approved, prospectively maintained joint database from 5 institutions. Tumors with malignant pathology were isolated and statistically analyzed for demographics and oncologic followup. The log rank test was used to compare recurrence-free and metastasis-free survival between patients with positive and negative surgical margins. The proportional hazards method was used to assess the influence of multiple factors, including positive surgical margins, on recurrence and metastasis. A total of 943 robot-assisted partial nephrectomies for malignant tumors were successfully completed. Of the patients 21 (2.2%) had positive surgical margins on final pathological assessment, resulting in 2 groups, including the 21 with positive surgical margins and 922 with negative surgical margins. Positive surgical margin cases had higher recurrence and metastasis rates (p<0.001). As projected by the Kaplan-Meier method in the population as a whole at followup out to 63.6 months, 5-year recurrence-free and metastasis-free survival was 94.8% and 97.5%, respectively. There was a statistically significant difference in recurrence-free and metastasis-free survival between patients with positive and negative surgical margins (log rank test<0.001), which favored negative surgical margins. Positive surgical margins showed an 18.4-fold higher HR for recurrence when adjusted for multiple tumors, tumor size, tumor growth pattern and pathological stage. Positive surgical margins on final pathological evaluation increase the HR of recurrence and metastasis. In addition to pathological and molecular tumor characteristics, this should be considered to plan appropriate management. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.

    PubMed

    Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2015-04-01

    The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.

  16. [A Paired Case Controlled Study Comparing the Short-term Outcomes of Da Vinci RATS and VATS Approach for Non-small Cell Lung Cancer].

    PubMed

    Dai, Feng; Xu, Shiguang; Xu, Wei; Ding, Renquan; Liu, Bo; Meng, Hao; Kang, Yunteng; Meng, Xiangrui; Lin, Jie; Wang, Shumin

    2018-03-20

    Da Vinci Surgical System is one of the greatest inventions of the 20th century, which represents the development direction of the precise minimally invasive surgical techniques, the aim of this study was to comparing the short-term outcomes between da Vinci robot-assisted lobectomy and video-assisted thoracic surgery (VATS) lobectomy for non-small cell lung cancer. 45 pairs of non-small cell lung cancer patients underwent pulmonary lobectomy with da Vinci Robotic assisted thoracoscopic (RATS) and VATS approach during the same period from January 2014 to January 2017. The operative time, estimated blood loss (EBL), total number and total groups of dissected lymph nodes, postoperative duration of drainage, the first day volume of drainage, total volume of drainage were compared. No perioperative death and convertion to thoracotomy occured in both groups. There were significant difference between RATS group and VATS group in EBL [(50.30±32.33) mL vs (208.60±132.63) mL], the first day volume of drainage [(275.00±145.42) mL vs (347.60±125.80) mL], the dissected total number [(22.67±9.67) vs (15.51±5.41)] and total team [(6.31±1.43) vs (4.91±1.04)] of lymph node. There were no significant difference in other outcomes. RATS is safe and effective and took better short-outcomes than VATS in non-small cell lung cancer.

  17. Robotic surgery, video-assisted thoracic surgery, and open surgery for early stage lung cancer: comparison of costs and outcomes at a single institute.

    PubMed

    Novellis, Pierluigi; Bottoni, Edoardo; Voulaz, Emanuele; Cariboni, Umberto; Testori, Alberto; Bertolaccini, Luca; Giordano, Laura; Dieci, Elisa; Granato, Lorenzo; Vanni, Elena; Montorsi, Marco; Alloisio, Marco; Veronesi, Giulia

    2018-02-01

    Robotic surgery is increasingly used to resect lung cancer. However costs are high. We compared costs and outcomes for robotic surgery, video-assisted thoracic surgery (VATS), and open surgery, to treat non-small cell lung cancer (NSCLC). We retrospectively assessed 103 consecutive patients given lobectomy or segmentectomy for clinical stage I or II NSCLC. Three surgeons could choose VATS or open, the fourth could choose between all three techniques. Between-group differences were assessed by Fisher's exact, two-way analysis of variance (ANOVA), and Wilcoxon-Mann-Whitney test. P values <0.05 were considered significant. Twenty-three patients were treated by robot, 41 by VATS, and 39 by open surgery. Age, physical status, pulmonary function, comorbidities, stage, and perioperative complications did not differ between the groups. Pathological tumor size was greater in the open than VATS and robotic groups (P=0.025). Duration of surgery was 150, 191 and 116 minutes, by robotic, VATS and open approaches, respectively (P<0.001). Significantly more lymph node stations were removed (P<0.001), and median length of stay was shorter (4, 5 and 6 days, respectively; P<0.001) in the robotic than VATS and open groups. Estimated costs were 82%, 68% and 69%, respectively, of the regional health service reimbursement for robotic, VATS and open approaches. Robotic surgery for early lung cancer was associated with shorter stay and more extensive lymph node dissection than VATS and open surgery. Duration of surgery was shorter for robotic than VATS. Although the cost of robotic thoracic surgery is high, the hospital makes a profit.

  18. Robotic-assisted pelvic lymph node dissection for prostate cancer: frequency of nodal metastases and oncological outcomes.

    PubMed

    Ledezma, Rodrigo A; Negron, Edris; Razmaria, Aria A; Dangle, Pankaj; Eggener, Scott E; Shalhav, Arieh L; Zagaja, Gregory P

    2015-11-01

    Limited data are available regarding the oncologic efficacy of pelvic lymph node dissection (PLND) performed during robotic-assisted laparoscopic prostatectomy (RALP) for prostate cancer. We aimed to determine the frequency of pelvic lymph node metastasis and oncological outcomes following RALP with PLND in patients who did not receive adjuvant androgen deprivation therapy (ADT). We retrospectively reviewed the records of 1740 consecutive patients who underwent RALP and extended PLND. The primary endpoint was biochemical recurrence (BCR). The estimated BCR probability was obtained using the Kaplan-Meier method. Cox proportional hazard regression models were used to assess for predictors of BCR. One hundred and eight patients (6 %) with positive LNs were identified. The median number of LNs removed was 17 (IQR 11-24), and median follow-up was 26 months (IQR 14-43). Ninety-one (84 %) patients did not receive adjuvant ADT of whom 60 % had BCR with a median time to recurrence of 8 months. The 1- and 3-year BCR-free probability was 42 and 28 %, respectively. Patients with ≤2 LN+ had significantly better biochemical-free estimated probability compared to those with >2 LN+ (p = 0.002). The total number of LN+ (HR = 1.1; 95 % CI 1.01-1.2, p = 0.04) and Gleason 8-10 (HR = 1.96; 95 % CI 1.1-3.4, p = 0.02) were predictors of BCR on multivariate analysis. Among men with positive lymph nodes at time of robotic prostatectomy, those with two or fewer positive nodes and Gleason <8 exhibited favorable biochemical-free survival without adjuvant therapy.

  19. Robotic-assisted single-port donor nephrectomy using the da Vinci single-site platform.

    PubMed

    LaMattina, John C; Alvarez-Casas, Josue; Lu, Irene; Powell, Jessica M; Sultan, Samuel; Phelan, Michael W; Barth, Rolf N

    2018-02-01

    Although single-port donor nephrectomy offers improved cosmetic outcomes, technical challenges have limited its application to selected centers. Our center has performed over 400 single-port donor nephrectomies. The da Vinci single-site robotic platform was utilized in an effort to overcome the steric, visualization, ergonomic, and other technical limitations associated with the single-port approach. Food and Drug Administration device exemption was obtained. Selection criteria for kidney donation included body mass index <35, left kidney donors, and ≤2 renal arteries. After colonic mobilization using standard single-port techniques, the robotic approach was utilized for ureteral complex and hilar dissection. Three cases were performed using the robotic single-site platform. Average total operative time was 262 ± 42 min including 82 ± 16 min of robotic use. Docking time took 20 ± 10 min. Blood loss averaged 77 ± 64 mL. No intraoperative complications occurred, and all procedures were completed with our standard laparoscopic single-port approach. This is the first clinical experience of robotic-assisted donor nephrectomy utilizing the da Vinci single-site platform. Our experience supported the safety of this approach but found that the technology added cost and complexity without tangible benefit. Development of articulating instruments, energy, and stapling devices will be necessary for increased application of robotic single-site surgery for donor nephrectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Stone formation from nonabsorbable clip migration into the collecting system after robot-assisted partial nephrectomy.

    PubMed

    Lee, Ziho; Reilly, Christopher E; Moore, Blake W; Mydlo, Jack H; Lee, David I; Eun, Daniel D

    2014-01-01

    We describe a case in which a Weck Hem-o-lok clip (Teleflex, Research Triangle Park, USA) migrated into the collecting system and acted as a nidus for stone formation in a patient after robot-assisted partial nephrectomy. The patient presented 2 years postoperatively with left-sided renal colic. Abdominal computed tomography scan showed a 10 millimeter renal calculus in the left middle pole. After using laser lithotripsy to fragment the overlying renal stone, a Weck Hem-o-lok clip was found to be embedded in the collecting system. A laser fiber through a flexible ureteroscope was used to successfully dislodge the clip from the renal parenchyma, and a stone basket was used to extract the clip.

  1. Robotic renal surgery: The future or a passing curiosity?

    PubMed Central

    Warren, Jeff; da Silva, Vitor; Caumartin, Yves; Luke, Patrick P.W.

    2009-01-01

    The development, advancement and clinical integration of robotic technology in surgery continue at a staggering pace. In no other discipline has this rapid evolution occurred to a greater degree than in urology. Although radical prostatectomy has grown to become the prototypical application for the robot, the role of the robot in renal surgery remains controversial. Herein we review the literature on robotic renal surgery. A comprehensive PubMed literature search was performed to identify all published reports relating to robotic renal surgery. All clinically related articles involving human participants were critically appraised in this review. Fifty-one clinical articles were included, encompassing robot-assisted pyeloplasty, nephrectomy, nephroureterectomy, living-donor nephrectomy and partial nephrectomy. Feasibility has been shown for each of these procedures. Robot-assisted techniques have been described for almost all renal-related procedures. However, the intersect between feasibility and necessity as it pertains to robotic renal surgery has yet to be defined. Also, the high cost of surgical robotic technology mandates critical appraisal before adoption, especially in a publicly funded health care system, such as the one present in Canada. PMID:19543471

  2. Reconstruction/Repair of Iatrogenic Biliary Injuries: Is the Robot Offering a New Option? Short Clinical Report.

    PubMed

    Giulianotti, Pier Cristoforo; Quadri, Pablo; Durgam, Samarth; Bianco, Francesco Maria

    2018-01-01

    The aim of this study is to analyze perioperative outcomes of robotic reconstruction of iatrogenic biliary injuries and describe the surgical technique in detail. Iatrogenic bile duct injuries (BDIs) continue to be a major concern in open and laparoscopic cholecystectomy. In the past decade, robotic surgery has been applied to many different procedures showing technical advantages, especially in microsurgical fields. Few cases of robotic BDI reconstructions have been described in the literature so far. This is the first clinical series of consecutive patients undergoing robotic BDI reconstructions. This study is a single-surgeon retrospective review of a prospectively maintained database including 14 patients who underwent robot-assisted biliary reconstruction due to iatrogenic BDIs. In all, 14 patients underwent robot-assisted BDI reconstructions. The mean operative time, blood loss, and length of hospitalization were 280.6 min (SD = 132.0), 135.0 mL (SD = 169.7), and 8.4 days (SD = 6.7), respectively. The conversion rate to open surgery was 0%. Long-term follow-up was available in 85.7% (12 out of 14 patients) with a mean follow-up of 36.1 months (SD = 28.1). The >30-day complication rate was 14.3% (n = 2). These 2 patients presented with recurrent episodes of cholangitis due to hepatico-jejunostomy mild stenosis, which were successfully treated with transhepatic percutaneous biliary drainage and multiple dilatations. Robot-assisted BDI reconstruction is feasible, safe, and may represent an interesting option in expert hands. It maintains all the benefits of minimally invasive surgery and seems to have technical advantages in fine dissection and microsuturing in the liver hilum (magnified microsuturing). In this series, 14 patients with major BDIs were repaired with the robotic approach, with conversion and reoperation rates of 0%. Long-term outcome evaluation requires a longer follow up and larger series, but the initial results are promising.

  3. First ALPPS procedure using a total robotic approach.

    PubMed

    Vicente, E; Quijano, Y; Ielpo, B; Fabra, I

    2016-12-01

    ALPPS procedure is gaining interest. Indications and technical aspects of this technique are still under debate [1]. Only 4 totally laparoscopic ALPPS procedures have been described in the literature and none by robotic approach [2-4]. This video demonstrates the technical aspects of totally robotic ALPPS. A 58 year old man with sigmoid adenocarcinoma with multiple right liver metastases extended to segment IV and I underwent Xelox and 5 Fluoro-uracil neoadjuvancy. Preoperative CT volumetric scan showed a FLR/TLV (Future Liver Remnant/Total Liver Volume) of 28%. ALPPS totally robotic procedure was planned using the DaVinci Si. Tumor resection from the FLR (including segment I) is followed by parenchymal transection between the FLR and the diseased part of the liver with concomitant right portal vein ligation. Small branches to segment IV from left portal vein have been resected along the round ligament, at this step. The right biliary tract was resected as it was partially debilitated after its dissection as partially encircled by a metastasis at segment IV. Second stage was performed totally robotic on 13th postoperative days with a FLR/TLV of 40%. No strong adherences are found, making this stage much easer than open approach. During this step, right hepatic artery and right supra hepatic vein are resected. Finally, the specimen was retrieved inside a plastic bag through a Pfannenstiel incision. Postoperative pathology showed margins free from disease. ALPPS procedure performed by robotic approach could be a safe and feasible technique in experienced centers with advanced robotic skills. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Total robotic pancreaticoduodenectomy: a systematic review of the literature.

    PubMed

    Kornaropoulos, Michail; Moris, Demetrios; Beal, Eliza W; Makris, Marinos C; Mitrousias, Apostolos; Petrou, Athanasios; Felekouras, Evangelos; Michalinos, Adamantios; Vailas, Michail; Schizas, Dimitrios; Papalampros, Alexandros

    2017-11-01

    Pancreaticoduodenectomy (PD) is a complex operation with high perioperative morbidity and mortality, even in the highest volume centers. Since the development of the robotic platform, the number of reports on robotic-assisted pancreatic surgery has been on the rise. This article reviews the current state of completely robotic PD. A systematic literature search was performed including studies published between January 2000 and July 2016 reporting PDs in which all procedural steps (dissection, resection and reconstruction) were performed robotically. Thirteen studies met the inclusion criteria, including a total of 738 patients. Data regarding perioperative outcomes such as operative time, blood loss, mortality, morbidity, conversion and oncologic outcomes were analyzed. No major differences were observed in mortality, morbidity and oncologic parameters, between robotic and non-robotic approaches. However, operative time was longer in robotic PD, whereas the estimated blood loss was lower. The conversion rate to laparotomy was 6.5-7.8%. Robotic PD is feasible and safe in high-volume institutions, where surgeons are experienced and medical staff are appropriately trained. Randomized controlled trials are required to further investigate outcomes of robotic PD. Additionally, cost analysis and data on long-term oncologic outcomes are needed to evaluate cost-effectiveness of the robotic approach in comparison with the open technique.

  5. The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steen-Banasik, Elzbieta M. van der, E-mail: E.vanderSteen-Banasik@radiotherapiegroep.nl; Smits, Geert A.H.J.; Oosterveld, Bernard J.

    Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach withmore » robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.« less

  6. Robot-assisted Heller's myotomy for achalasia in children.

    PubMed

    Altokhais, Tariq; Mandora, Hala; Al-Qahtani, Ayed; Al-Bassam, Abdulrahman

    2016-12-01

    Achalasia is rare in children. Surgical options include open, laparoscopic and robotic approaches. However, Heller's myotomy remains the treatment of choice. This report describes our experience with robot-assisted Heller's myotomy in children and presents a review of the literature. Included in this study are children who underwent robot-assisted Heller's myotomy for esophageal achalasia via the Da Vinci surgical system between 2004 and 2015 at King Saud University Medical City, Riyadh, Saudi Arabia. The medical records of these patients were reviewed for demographic data, presenting symptoms, diagnostic modalities, operative procedures, complications, outcomes and follow-ups. Six patients were identified. The age of the patients at surgery ranged between 2 and 12 years (mean 7.1 years). The most common presenting symptoms were dysphagia, vomiting and nocturnal cough. Contrast swallow and upper gastrointestinal endoscopy established a diagnosis of esophageal achalasia in all of the patients. Four patients underwent esophageal dilatation 2-5 times before the definitive procedure. All patients underwent successful robot-assisted Heller's myotomy with concomitant partial posterior fundoplication. The postoperative course was uneventful. Five patients had a complete resolution of the symptoms and one patient improved. The follow-up assessments have been consistent and have ranged from 0.5 to 11 years (mean 4.4 years). Robotic-assisted Heller's myotomy for esophageal achalasia in children is safe and effective and is a suitable alternative to open and laparoscopic approaches.

  7. [Application of Da Vinci surgical robot in the dissection of splenic hilar lymph nodes for gastric cancer patients with total gastrectomy].

    PubMed

    Yang, Kun; Chen, Xinzu; Zhang, Weihan; Chen, Xiaolong; Hu, Jiankun

    2016-08-25

    To investigate the feasibility and safety of Da Vinci surgical robot in the dissection of splenic hilar lymph nodes for gastric cancer patients with total gastrectomy. Clinical data of two cases who underwent total gastrectomy for cardia cancer at our department in January 2016 were analyzed retrospectively. Two male patients were 62 and 55 years old respectively, with preoperative diagnosis as cT2-3N0M0 and cT1-2N0M0 gastric cancer by gastroscope and biopsy, and both received robotic total gastrectomy spleen-preserving splenic hilar lymph node dissection successfully. The operative time for splenic hilar lymph node dissection was 30 min and 25 min respectively. The intraoperative estimated blood loss was both 100 ml, while the number of total harvested lymph node was 38 and 33 respectively. One dissected splenic hilar lymph node and fatty tissues in two patients were proven by pathological examinations. There were no anastomotic leakage, pancreatic fistula, splenic infarction, intraluminal bleeding, digestive tract bleeding, aneurysm of splenic artery, and other operation-associated complications. Both patients suffered from postoperative pneumonia, and were cured by conservative therapy. The robotic spleen-preserving splenic hilar lymph node dissection is feasible and safe, but its superiority needs further evaluation.

  8. Dissection of intercostal nerves by means of assisted video thoracoscopy: experimental study

    PubMed Central

    2013-01-01

    In total brachial plexus preganglionic lesions (C5-C6-C7-C8 and T1) different extraplexual neurotizations are indicated for partial motor function restitution. Mostly for the flexion of the elbow. Neurotization with intercostal nerves (ICN) to musculocutaneous nerve has been known and accepted during many years with different results 2 - 5. The customary technique as described by various authors is carried out by means of a large submammary incision to harvest three or four intercostal nerves (Figure 1). Then are connected by direct suture or grafts to the musculocutaneous nerve or its motor branches 6 - 7. In this article the authors described the possibility of dissection intercostal nerves by means of assisted video thoracoscopy. (VATS-videdo assisted thoracic surgery). PMID:23406448

  9. Cost-analysis comparison of robot-assisted laparoscopic radical cystectomy (RC) vs open RC.

    PubMed

    Lee, Richard; Chughtai, Bilal; Herman, Michael; Shariat, Shahrokh F; Scherr, Douglas S

    2011-09-01

    • To systematically review and compare the economic burden of open radical cystectomy (ORC) vs robot-assisted laparoscopic radical cystectomy (RALRC) with pelvic lymph node dissection and urinary diversion. • A Medline search was conducted to identify English language articles regarding RC with urinary diversion. The resulting articles were then further restricted by the terms 'laparoscopic', 'robotic', or 'robotic-assisted'.In all, three articles were identified. • Data from each of these articles were then collected on cost performance in addition to relevant clinical variables, such as length of stay (LOS), operative duration, and complication rates. • When possible, data were subdivided by ileal conduit (IC), continent cutaneous diversion (CCD), and orthotopic neobladder (ON) subgroups. • Direct costs resulting from ORC or RALRC with accompanying hospitalization were identified. The indirect costs of complications were considered. • Despite an increased materials cost, RALRC was less expensive than ORC when the cost of complications was considered. • RALRC was less expensive than ORC for IC and CCD, but the cost advantage deteriorated for ON. • The largest cost drivers cited in the published data were LOS, operative durations, and daily hospitalizations costs. • RALRC demonstrated shorter LOS compared with ORC, although this effect was insufficient to offset the increased cost of robotic surgery. • Complications materially affected cost performance. • Despite an increased materials cost, RALRC can be more cost efficient than ORC as a treatment for bladder cancer when the impact of complications are considered. • This effect is most pronounced for patients undergoing IC. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  10. Initial experience with the new da Vinci single-port robot-assisted platform.

    PubMed

    Ballestero Diego, R; Zubillaga Guerrero, S; Truan Cacho, D; Carrion Ballardo, C; Velilla Diez, G; Calleja Hermosa, P; Gutiérrez Baños, J L

    2017-06-01

    To describe our experience in the first cases of urological surgeries performed with the da Vinci single-port robot-assisted platform. We performed 5 single-port robot-assisted surgeries (R-LESS) between May and October 2014. We performed 3 ureteral reimplant surgeries, one ureteropyeloplasty in an inverted kidney and 1 partial nephrectomy. The perioperative and postoperative results were collected, as well as a report of the complications according to the Clavien classification system. Of the 5 procedures, 4 were performed completely by LESS, while 1 procedure was reconverted to multiport robot-assisted surgery. There were no intraoperative complications. We observed perioperative complications in 4 patients, all of which were grade 1 or 2. The mean surgical time was 262minutes (range, 230-300). In our initial experience with the da Vinci device, R-LESS surgery was feasible and safe. There are still a number of limitations in its use, which require new and improved R-LESS platforms. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Robot-Assisted Partial Nephrectomy for T1b Tumors: Strict Trifecta Outcomes.

    PubMed

    Tufek, Ilter; Mourmouris, Panagiotis; Doganca, Tunkut; Obek, Can; Argun, Omer Burak; Tuna, Mustafa Bilal; Keskin, Mehmet Selcuk; Kural, Ali Rıza

    2017-01-01

    "Trifecta" in partial nephrectomy consists of negative surgical margins, minimal renal function decrease and absence of complications. In the present article, our single-center robot-assisted partial nephrectomy (RAPN) experience in T1b renal masses is reported in terms of strict Trifecta outcomes. This is a retrospective analysis of patients with a tumor diameter between 4 and 7 cm (stage T1b), who underwent RAPN by a single surgeon. Preoperative, intraoperative, and postoperative data were recorded and analyzed to evaluate short-term functional and oncologic outcomes. Patients with absence of grade ≥ 2 Clavien-Dindo complications, warm ischemia time (WIT) ≤25 minutes, ≤15% postoperative estimated glomerular filtration rate (eGFR) decrease and negative surgical margins were reported to achieve strict Trifecta outcomes. P < .05 was indicated statistically significant. A total of 150 patients underwent RAPN, and 50 patients were identified with tumor size between 4 and 7 cm. Mean WIT was 20.8 ± 6.2 minutes and mean estimated blood loss (EBL) was 269 ± 191 mL. Surgical margins were negative in all patients. Eleven patients (22%) had a >15% eGFR decrease after surgery. Nine patients (18%) had WIT longer than 25 minutes. Four patients (8%) had grade ≥2 Clavien-Dindo complications. Twenty-nine (58%) patients had strict Trifecta outcomes. Mean follow-up was 44.2 ± 27.2 months. Tumor recurrence was not observed in any patient. Robot-assisted laparoscopic partial nephrectomy for T1b renal masses can be safely performed in experienced hands. Optimal strict Trifecta outcomes and recurrence rates can be achieved.

  12. Transoral robotic thyroid surgery

    PubMed Central

    Clark, James H.; Kim, Hoon Yub

    2015-01-01

    There is currently significant demand for minimally invasive thyroid surgery; however the majority of proposed surgical approaches necessitate a compromise between minimal tissue dissection with a visible cervical scar or extensive tissue dissection with a remote, hidden scar. The development of transoral endoscopic thyroid surgery however provides an approach which is truly minimally invasive, as it conceals the incision within the oral cavity without significantly increasing the amount of required dissection. The transoral endoscopic approach however presents multiple technical challenges, which could be overcome with the incorporation of a robotic operating system. This manuscript summarizes the literature on the feasibility and current clinical experience with transoral robotic thyroid surgery. PMID:26425456

  13. Forces exerted during microneurosurgery: a cadaver study

    PubMed Central

    Marcus, Hani J; Zareinia, Kourosh; Gan, Liu Shi; Yang, Fang Wei; Lama, Sanju; Yang, Guang-Zhong; Sutherland, Garnette R

    2014-01-01

    Background A prerequisite for the successful design and use of robots in neurosurgery is knowledge of the forces exerted by surgeons during neurosurgical procedures. The aim of the present cadaver study was to measure the surgical instrument forces exerted during microneurosurgery. Methods An experimental apparatus was set up consisting of a platform for human cadaver brains, a Leica microscope to provide illumination and magnification, and a Quanser 6 Degrees-Of-Freedom Telepresence System for tissue manipulation and force measurements. Results The measured forces varied significantly depending on the region of the brain (P = 0.016) and the maneuver performed (P < 0.0001). Moreover, blunt arachnoid dissection was associated with greater force exertion than sharp dissection (0.22 N vs. 0.03 N; P = 0.001). Conclusions The forces necessary to manipulate brain tissue were surprisingly low and varied depending on the anatomical structure being manipulated, and the maneuver performed. Knowledge of such forces could well increase the safety of microsurgery. © 2014 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons, Ltd. PMID:24431265

  14. Direct target NOTES: prospective applications for next generation robotic platforms.

    PubMed

    Atallah, S; Hodges, A; Larach, S W

    2018-05-01

    A new era in surgical robotics has centered on alternative access to anatomic targets and next generation designs include flexible, single-port systems which follow circuitous rather than straight pathways. Such systems maintain a small footprint and could be utilized for specialized operations based on direct organ target natural orifice transluminal endoscopic surgery (NOTES), of which transanal total mesorectal excision (taTME) is an important derivative. During two sessions, four direct target NOTES operations were conducted on a cadaveric model using a flexible robotic system to demonstrate proof-of-concept of the application of a next generation robotic system to specific types of NOTES operations, all of which required removal of a direct target organ through natural orifice access. These four operations were (a) robotic taTME, (b) robotic transvaginal hysterectomy in conjunction with (c) robotic transvaginal salpingo-oophorectomy, and in an ex vivo model, (d) trans-cecal appendectomy. Feasibility was demonstrated in all cases using the Flex ® Robotic System with Colorectal Drive. During taTME, the platform excursion was 17 cm along a non-linear path; operative time was 57 min for the transanal portion of the dissection. Robotic transvaginal hysterectomy was successfully completed in 78 min with transvaginal extraction of the uterus, although laparoscopic assistance was required. Robotic transvaginal unilateral salpingo-oophorectomy with transvaginal extraction of the ovary and fallopian tube was performed without laparoscopic assistance in 13.5 min. In an ex vivo model, a robotic trans-cecal appendectomy was also successfully performed for the purpose of demonstrating proof-of-concept only; this was completed in 24 min. A flexible robotic system has the potential to access anatomy along circuitous paths, making it a suitable platform for direct target NOTES. The conceptual operations posed could be considered suitable for next generation robotics once the technology is optimized, and after further preclinical validation.

  15. Development and Assessment of a Transoral Robotic Surgery Curriculum to Train Otolaryngology Residents.

    PubMed

    White, Joseph; Sharma, Arun

    2018-05-30

    (1) To develop a multifaceted didactic and hands-on curriculum to prepare otolaryngology residents to perform transoral robotic surgery (TORS) and safely transition to the operating room. (2) To assess the effectiveness of the TORS curriculum. Learning objectives were developed and a curriculum was formulated utilizing five unique modalities: focused didactic reading, online training modules, backpack console simulations, videos of TORS cases, and hands-on cadaveric dissections with the robotic surgical system in a simulated operating room. The trainees completed a nine-item self-assessment of their skill level using a Likert scale. Five senior otolaryngology residents completed the TORS curriculum. Before and after the cadaveric dissections, there was improvement in each of the nine items assessed. Composite scores were calculated and there was significant improvement from predissection (15.2 ± 2.2) to postdissection (31.4 ± 1.9) (p = 0.002). The current study demonstrates the feasibility of implementing a multifaceted TORS curriculum which incorporates robotic cadaveric dissection for otolaryngology residents. Residents demonstrate marked improvement in skills with the TORS curriculum. A TORS curriculum which includes robotic cadaveric dissection can improve surgical skills and serve as a key component of residency TORS education. © 2018 S. Karger AG, Basel.

  16. Robotic partial nephrectomy for duplex kidney with ectopic ureter draining in the vagina in an adult patient with urinary incontinence.

    PubMed

    Mahmood, Humza; Hadjipavlou, Marios; Das, Raj; Anderson, Chris

    2017-02-06

    A duplex kidney system with an ectopic ureter draining into the vagina is a congenital malformation that typically presents as refractory urinary incontinence. Diagnosis is often difficult to establish and delayed due to a low incidence. We present the case of a patient aged 26 years with a life-long history of persistent urinary incontinence. Initial presentation was at childhood; however, the diagnosis went undetermined for 22 years. CT urography revealed a duplex kidney with an atrophic upper pole associated with an ectopic ureter that drained into the vaginal vault. This is the first description of such a case being managed successfully via a robot-assisted partial nephrectomy approach. Ectopic ureteral duplication should be considered in the differential diagnosis for young women with refractory urinary incontinence. Robotic partial nephrectomy is a safe and effective technique to manage such cases. 2017 BMJ Publishing Group Ltd.

  17. Partial nephrectomy for small children: Robot-assisted versus open surgery.

    PubMed

    Ballouhey, Quentin; Binet, Aurélien; Clermidi, Pauline; Braik, Karim; Villemagne, Thierry; Cros, Jérôme; Lardy, Hubert; Fourcade, Laurent

    2017-12-01

    To compare the outcomes of robot-assisted heminephrectomy for duplex kidney in children with those of open heminephrectomy. The present retrospective multicentric analysis reviewed the records of robot-assisted versus open heminephrectomy carried out for duplex kidney in children from 2007 to 2014. Demographic data, weight, surgical time, hospital stay, complications and outcome were recorded. Follow up was based on a clinical review, renal sonography and dimercaptosuccinic acid renal scintigraphy. A total of 15 patients underwent robot-assisted heminephrectomy, and 13 patients underwent retroperitoneal heminephrectomy by open approach. All patients weighed <15 kg. The mean age at the time of surgery was 20.2 months (range 7-39 months) in the robotic group, and 18.4 months (range 6-41 months) in the open group. The mean hospital stay was statistically longer for the open surgery group (6.3 days, range 5-8 days vs 3.4 days, range 1-7 days; P < 0.001). Regarding postoperative pain control, total morphine equivalent intake was statistically greater for the open group (0.52 mg/kg/day vs 1.08 mg/kg/day; P < 0.001). No patient lost the remaining healthy moiety. There was no significant difference in terms of operating time, complication rate or renal outcomes. Robot-assisted heminephrectomy in small children seems to offer comparable renal outcomes with those of its standard open surgery counterpart. Specific technical adjustments are necessary, which typically increase the set-up time. © 2017 The Japanese Urological Association.

  18. Robot-assisted approach improves surgical outcomes in obese patients undergoing partial nephrectomy.

    PubMed

    Malkoc, Ercan; Maurice, Matthew J; Kara, Onder; Ramirez, Daniel; Nelson, Ryan J; Caputo, Peter A; Mouracade, Pascal; Stein, Robert; Kaouk, Jihad H

    2017-02-01

    To assess the impact of approach on surgical outcomes in otherwise healthy obese patients undergoing partial nephrectomy for small renal masses. Using our institutional partial nephrectomy database, we abstracted data on otherwise healthy (Charlson comorbidity score ≤1 and bilateral kidneys), obese patients (body mass index >30 kg/m 2 ) with small renal masses (<4 cm) treated between 2011 and 2015. The primary outcomes were intra-operative transfusion, operating time, length of hospital stay (LOS), and postoperative complications. The association between approach, open (OPN) vs robot-assisted partial nephrectomy (RAPN), and outcomes was assessed by univariable and multivariable logistic regression analyses. Covariates included age, gender, obesity severity, tumour size and tumour complexity. Of 237 obese patients undergoing partial nephrectomy, 25% underwent OPN and 75% underwent RAPN. Apart from larger tumour size in the OPN group (2.8 vs 2.5 cm; P = 0.02), there was no significant difference between groups. The rate of intra-operative blood transfusion (1.1 vs 10%; P = 0.01), the median operating time (180 vs 207 min; P < 0.01) and the median ischaemia time (19.5 vs 27 min; P < 0.01) were all greater for OPN. The LOS was significantly shorter for RAPN (3 vs 4 days; P < 0.01). While the overall complication rate was higher for OPN (15.8 vs 31.7%; P < 0.01), major complications were not significantly different (5.6 vs 1.7%; P = 0.20). On multivariable analyses, OPN independently predicted longer operating time, longer length of stay, and more overall complications. At a high-volume centre, the robot-assisted approach offers less blood transfusion, shorter operating time, faster recovery, and fewer peri-operative complications compared with the open approach in obese patients undergoing partial nephrectomy for small renal masses. In this setting, RAPN may be a preferable treatment option. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  19. A multimodal imaging framework for enhanced robot-assisted partial nephrectomy guidance

    NASA Astrophysics Data System (ADS)

    Halter, Ryan J.; Wu, Xiaotian; Hartov, Alex; Seigne, John; Khan, Shadab

    2015-03-01

    Robot-assisted laparoscopic partial nephrectomies (RALPN) are performed to treat patients with locally confined renal carcinoma. There are well-documented benefits to performing partial (opposed to radical) kidney resections and to using robot-assisted laparoscopic (opposed to open) approaches. However, there are challenges in identifying tumor margins and critical benign structures including blood vessels and collecting systems during current RALPN procedures. The primary objective of this effort is to couple multiple image and data streams together to augment visual information currently provided to surgeons performing RALPN and ultimately ensure complete tumor resection and minimal damage to functional structures (i.e. renal vasculature and collecting systems). To meet this challenge we have developed a framework and performed initial feasibility experiments to couple pre-operative high-resolution anatomic images with intraoperative MRI, ultrasound (US) and optical-based surface mapping and kidney tracking. With these registered images and data streams, we aim to overlay the high-resolution contrast-enhanced anatomic (CT or MR) images onto the surgeon's view screen for enhanced guidance. To date we have integrated the following components of our framework: 1) a method for tracking an intraoperative US probe to extract the kidney surface and a set of embedded kidney markers, 2) a method for co-registering intraoperative US scans with pre-operative MR scans, and 3) a method for deforming pre-op scans to match intraoperative scans. These components have been evaluated through phantom studies to demonstrate protocol feasibility.

  20. Cost-Benefit Performance Simulation of Robot-Assisted Thoracic Surgery As Required for Financial Viability under the 2016 Revised Reimbursement Paradigm of the Japanese National Health Insurance System.

    PubMed

    Kajiwara, Naohiro; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-04-20

    To discuss the cost-benefit performance (CBP) and establish a medical fee system for robotic-assisted thoracic surgery (RATS) under the Japanese National Health Insurance System (JNHIS), which is a system not yet firmly established. All management steps for RATS are identical, such as preoperative and postoperative management. This study examines the CBP based on medical fees of RATS under the JNHIS introduced in 2016. Robotic-assisted laparoscopic prostatectomy (RALP) and robotic-assisted partial nephrectomy (RAPN) now receive insurance reimbursement under the category of use of support devices for endoscopic surgery ($5420 and $3485, respectively). If the same standard amount were to be applied to RATS, institutions would need to perform at least 150 or 300 procedures thoracic operation per year to show a positive CBP ($317 per procedure as same of RALP and $130 per procedure as same of RAPN, respectively). Robotic surgery in some areas receives insurance reimbursement for its "supportive" use for endoscopic surgery as for RALP and RAPN. However, at present, it is necessary to perform da Vinci Surgical System Si (dVSi) surgery at least 150-300 times in a year in a given institution to prevent a deficit in income.

  1. Simultaneous bilateral robotic partial nephrectomy: Case report and critical evaluation of the technique.

    PubMed

    Giberti, Claudio; Gallo, Fabrizio; Schenone, Maurizio; Cortese, Pierluigi

    2014-06-16

    We report our first simultaneous bilateral robot assisted partial nephrectomy (RAPN) in order to show and critically discuss the feasibility of this procedure. Materials and methods A 69-year-old male patient visited our department due to incidental finding of bilateral mesorenal small masses (2.5 cm on the right and 3.5 cm on the left) suspicious for malignancy. We started from the right side with patient in flank position. Port placement: 12-mm periumbilical camera port, two 8-mm robotic ports in wide ''V''configuration, additional 12 mm assistant port on the midline between the umbilicus and symphysis pubis. A right unclamping RAPN with sliding clip renorrhaphy was performed. The trocars were removed and the robot undocked. Without interrupting the anesthesiological procedures, the patient was reported in supine position and, after 180 degrees rotation of the surgical bed, was newly placed in contralateral flank position. Using both the previous periumbilical and midline ports, two other 8-mm robotic trocars were placed. The robot was then redocked and RAPN was also performed on the left side using the same previously reported technique. Results Total time: 285 min. Estimated blood losses: 150 cc. Postoperative period: uneventful. Pathological examination: bilateral renal cell carcinoma, negative surgical margins. Conclusions Our experience was encouraging and confirmed the feasibility and safety of this procedure. The planning of our technique was time and cost effective with cosmetic benefit for the patient. However, we think that an appropriate selection of the patients and a skill in robotic renal surgery are advisable before approaching this type of surgery.

  2. Robotic assisted laparoscopic partial nephrectomy using contrast‐enhanced ultrasound scan to map renal blood flow

    PubMed Central

    Motiwala, Aamir; Eves, Susannah; Gray, Rob; Thomas, Asha; Meiers, Isabelle; Sharif, Haytham; Motiwala, Hanif; Laniado, Marc; Karim, Omer

    2016-01-01

    Abstract Objective The paper describes novel real‐time ‘in situ mapping’ and ‘sequential occlusion angiography’ to facilitate selective ischaemia robotic partial nephrectomy (RPN) using intraoperative contrast enhanced ultrasound scan (CEUS). Materials and methods Data were collected and assessed for 60 patients (61 tumours) between 2009 and 2013. 31 (50.8%) tumours underwent ‘Global Ischaemia’, 27 (44.3%) underwent ‘Selective Ischaemia’ and 3 (4.9%) were removed ‘Off Clamp Zero Ischaemia’. Demographics, operative variables, complications, renal pathology and outcomes were assessed. Results Median PADUA score was 9 (range 7–10). The mean warm ischaemia time in selective ischaemia was less and statistically significant than in global ischaemia (17.1 and 21.4, respectively). Mean operative time was 163 min. Postoperative complications (n = 10) included three (5%) Clavien grade 3 or above. Malignancy was demonstrated in 47 (77%) with negative margin in 43 (91.5%) and positive margin in four (8.5%). Long‐term decrease in eGFR post selective ischaemia robotic partial nephrectomy was less compared with global ischaemia (four and eight, respectively) but not statistically significant. Conclusions This technique is safe, feasible and cost‐effective with comparable perioperative outcomes. The technical aspects elucidate the role of intraoperative CEUS to facilitate and ascertain selective ischaemia. Further work is required to demonstrate long‐term oncological outcomes. © 2016 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons, Ltd. PMID:26948671

  3. Dexterity optimization by port placement in robot-assisted minimally invasive surgery

    NASA Astrophysics Data System (ADS)

    Selha, Shaun; Dupont, Pierre; Howe, Robert D.; Torchiana, David F.

    2002-02-01

    A computer-based algorithm has been developed which uses preoperative images to provide a surgeon with a list of feasible port triplets ranked according to tool dexterity and endoscopic view quality at each surgical site involved in a procedure. A computer simulation allows the surgeon to select from among the proposed port locations. The procedure selected for the development of the system consists of a coronary artery bypass graft (CABG). In this procedure, the interior mammary artery (IMA) is mobilized from the interior chest wall, and one end is attached to the coronary arteries to provide a new blood supply for the heart. Approximately 10-20 cm is dissected free, using blunt dissection and a harmonic scalpel or electrocautery. At present, the port placement system is being evaluated in clinical trials.

  4. Totally robotic repair of atrioventricular septal defect in the adult.

    PubMed

    Gao, Changqing; Yang, Ming; Xiao, Cangsong; Zhang, Huajun

    2015-11-06

    Atrioventricular septal defect (AVSD) accounts for up to 3 % of congenital cardiac defects, which is routinely repaired via median sternotomy. Minimally invasive approach such as endoscopic or robotic assisted repair for AVSD has not been reported in the literature. With the experience with robotic mitral valve surgery and congenital defect repair, we initiated robotic AVSD repair in adults. In this report, we presented three cases of successful repair of partial and intermediate AVSD by using da Vinci SI surgical system (Intuitive Surgical, Inc., Sunnyvale, CA). Totally robotic AVSD repair via right atriotomy could be safely performed in adults and it may provide superior cosmesis with the comparable surgical outcome of the repair via sternotomy.

  5. Systematic review and cumulative analysis of oncologic and functional outcomes after robot-assisted radical cystectomy.

    PubMed

    Yuh, Bertram; Wilson, Timothy; Bochner, Bernie; Chan, Kevin; Palou, Joan; Stenzl, Arnulf; Montorsi, Francesco; Thalmann, George; Guru, Khurshid; Catto, James W F; Wiklund, Peter N; Novara, Giacomo

    2015-03-01

    Although open radical cystectomy (ORC) is still the standard approach, laparoscopic radical cystectomy (LRC) and robot-assisted radical cystectomy (RARC) are increasingly performed. To report on a systematic literature review and cumulative analysis of pathologic, oncologic, and functional outcomes of RARC in comparison with ORC and LRC. Medline, Scopus, and Web of Science databases were searched using a free-text protocol including the terms robot-assisted radical cystectomy or da Vinci radical cystectomy or robot* radical cystectomy. RARC case series and studies comparing RARC with either ORC or LRC were collected. A cumulative analysis was conducted. The searches retrieved 105 papers, 87 of which reported on pathologic, oncologic, or functional outcomes. Most series were retrospective and had small case numbers, short follow-up, and potential patient selection bias. The lymph node yield during lymph node dissection was 19 (range: 3-55), with half of the series following an extended template (yield range: 11-55). The lymph node-positive rate was 22%. The performance of lymphadenectomy was correlated with surgeon and institutional volume. Cumulative analyses showed no significant difference in lymph node yield between RARC and ORC. Positive surgical margin (PSM) rates were 5.6% (1-1.5% in pT2 disease and 0-25% in pT3 and higher disease). PSM rates did not appear to decrease with sequential case numbers. Cumulative analyses showed no significant difference in rates of surgical margins between RARC and ORC or RARC and LRC. Neoadjuvant chemotherapy use ranged from 0% to 31%, with adjuvant chemotherapy used in 4-29% of patients. Only six series reported a mean follow-up of >36 mo. Three-year disease-free survival (DFS), cancer-specific survival (CSS), and overall survival (OS) rates were 67-76%, 68-83%, and 61-80%, respectively. The 5-yr DFS, CSS, and OS rates were 53-74%, 66-80%, and 39-66%, respectively. Similar to ORC, disease of higher pathologic stage or evidence of lymph node involvement was associated with worse survival. Very limited data were available with respect to functional outcomes. The 12-mo continence rates with continent diversion were 83-100% in men for daytime continence and 66-76% for nighttime continence. In one series, potency was recovered in 63% of patients who were evaluable at 12 mo. Oncologic and functional data from RARC remain immature, and longer-term prospective studies are needed. Cumulative analyses demonstrated that lymph node yields and PSM rates were similar between RARC and ORC. Conclusive long-term survival outcomes for RARC were limited, although oncologic outcomes up to 5 yr were similar to those reported for ORC. Although open radical cystectomy (RC) is still regarded as the standard treatment for muscle-invasive bladder cancer, laparoscopic and robot-assisted RCs are becoming more popular. Templates of lymph node dissection, lymph node yields, and positive surgical margin rates are acceptable with robot-assisted RC. Although definitive comparisons with open RC with respect to oncologic or functional outcomes are lacking, early results appear comparable. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Understanding Cognitive Performance During Robot-Assisted Surgery.

    PubMed

    Guru, Khurshid A; Shafiei, Somayeh B; Khan, Atif; Hussein, Ahmed A; Sharif, Mohamed; Esfahani, Ehsan T

    2015-10-01

    To understand cognitive function of an expert surgeon in various surgical scenarios while performing robot-assisted surgery. In an Internal Review Board approved study, National Aeronautics and Space Administration-Task Load Index (NASA-TLX) questionnaire with surgical field notes were simultaneously completed. A wireless electroencephalography (EEG) headset was used to monitor brain activity during all procedures. Three key portions were evaluated: lysis of adhesions, extended lymph node dissection, and urethro-vesical anastomosis (UVA). Cognitive metrics extracted were distraction, mental workload, and mental state. In evaluating lysis of adhesions, mental state (EEG) was associated with better performance (NASA-TLX). Utilizing more mental resources resulted in better performance as self-reported. Outcomes of lysis were highly dependent on cognitive function and decision-making skills. In evaluating extended lymph node dissection, there was a negative correlation between distraction level (EEG) and mental demand, physical demand and effort (NASA-TLX). Similar to lysis of adhesion, utilizing more mental resources resulted in better performance (NASA-TLX). Lastly, with UVA, workload (EEG) negatively correlated with mental and temporal demand and was associated with better performance (NASA-TLX). The EEG recorded workload as seen here was a combination of both cognitive performance (finding solution) and motor workload (execution). Majority of workload was contributed by motor workload of an expert surgeon. During UVA, muscle memory and motor skills of expert are keys to completing the UVA. Cognitive analysis shows that expert surgeons utilized different mental resources based on their need. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Association between surgeon and hospital characteristics and lymph node counts from radical prostatectomy and pelvic lymph node dissection.

    PubMed

    Wang, Elyn H; Yu, James B; Gross, Cary P; Abouassaly, Robert; Cherullo, Edward E; Smaldone, Marc C; Shah, Nilay D; Kiechle, Jonathon; Trinh, Quoc-Dien; Sun, Maxine; Kim, Simon P

    2015-04-01

    To assess whether surgical approach and hospital characteristics independently determine the number of lymph nodes (LNs) removed from prostate cancer patients undergoing radical prostatectomy (RP) and pelvic LN dissection (PLND). Using the National Cancer Database, we identified all surgically treated patients diagnosed with pretreatment intermediate- or high-risk prostate cancer from 2010 to 2011. The primary outcome was the number of LNs retrieved at the time of RP. Generalized estimating equations were used to assess for differences in the adjusted number of LNs retrieved after accounting for patient and hospital characteristics and surgical approach. Overall, 35,876 patients were diagnosed with intermediate-risk (61.2%) and high-risk (38.8%) prostate cancer and underwent RP and PLND.On multivariate analysis, open RP and high-volume and academic hospitals were independently associated with greater LN counts compared with robotic-assisted RP and medium or low and community hospitals, respectively (all P <.001). After adjusting for patient and hospital variables, higher adjusted LN counts were observed for open RP compared with robotic-assisted RP (7.1 vs 6.1; P <.001). Adjusted counts were also higher for high-volume hospitals compared with medium- or low-volume hospitals (7.8 vs 5.9; P <.001), and academic compared with community hospitals (7.3 vs 5.6; P <.001). Among patients with aggressive prostate cancer treated with RP and PLND, retrieval of LN counts varied by surgical approach and hospital characteristics. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. The First 24 Robotic Surgeries of Hospital da Luz.

    PubMed

    Eurico Reis, João; Santos Silva, João; Costa, Ana Rita; Palma Martelo, Fernando

    2017-01-01

    Robotic assisted thoracic surgery (RATS) has been growing all over the world, presenting itself as an improvement over video-assisted thoracic surgery (VATS). The main advantages are the precision of the movements, as well as the three-dimensional vision with the consequent perception of the depth of the surgical field. Thus, technically more difficult procedures, such as anatomic segmentectomies and bronchoplastic resections, are facilitated. This surgical approach also improves the quality of mediastinal lymph node dissection, extremely important in lung cancer patients. Analysis of the first 24 robotic thoracic surgeries performed at Hospital da Luz. All robotic thoracic surgeries performed at Hospital da Luz from 2/6/2016 to this date were evaluated, concerning diagnosis, type of surgery, chest drainage time, hospitalization time, morbidity and mortality. Twenty-four RATS were performed, with patients having a mean age of 60.5 (39-76) years, eleven of them being male. All surgeries were performed with 3 ports of 8mm and a 12mm port for the assistant. Eighteen surgeries of pulmonary resection (75%), five surgeries for mediastinal lesions (20.8%), and one for intercostal nerve harvest for reinnervation of the brachial plexus, were performed. In the pulmonary surgeries, eleven were lobectomies (61.1%), five were anatomic segmentectomies (27.8%) and two wedge resections (11.1%). Neoplastic disease was the reason for the sixteen lung anatomic resections, two for metastatic disease and fourteen for primary lung cancer. In each case, a systemic lymph node dissection was performed. All procedures were performed without intra- or postoperative complications. Mean drainage time was 3.4 days [2-6], and mean hospitalization time was 4.8 days [3-8]. There were no mortality or major morbidity. There were two patients with prolonged air-leak up to 6 days. The morbidity after discharge was 12.5%, consisting of an apical pneumothorax that resolved spontaneously, a basal pleural effusion that resolved with outpatient thoracentesis, and a respiratory infection treated with antibiotic. The overall evaluation of this technique is still precocious, but allows to affirm that an experienced surgeon in vats surgery has a faster learning curve with this new approach. The innovation and development of new techniques in thoracic surgery are fundamental in order to allow more effective treatments, with less pain and, when possible, lung parenchyma sparing surgeries in patients with early neoplastic lung disease.

  9. Performance-based robotic assistance during rhythmic arm exercises.

    PubMed

    Leconte, Patricia; Ronsse, Renaud

    2016-09-13

    Rhythmic and discrete upper-limb movements are two fundamental motor primitives controlled by different neural pathways, at least partially. After stroke, both primitives can be impaired. Both conventional and robot-assisted therapies mainly train discrete functional movements like reaching and grasping. However, if the movements form two distinct neural and functional primitives, both should be trained to recover the complete motor repertoire. Recent studies show that rhythmic movements tend to be less impaired than discrete ones, so combining both movement types in therapy could support the execution of movements with a higher degree of impairment by movements that are performed more stably. A new performance-based assistance method was developed to train rhythmic movements with a rehabilitation robot. The algorithm uses the assist-as-needed paradigm by independently assessing and assisting movement features of smoothness, velocity, and amplitude. The method relies on different building blocks: (i) an adaptive oscillator captures the main movement harmonic in state variables, (ii) custom metrics measure the movement performance regarding the three features, and (iii) adaptive forces assist the patient. The patient is encouraged to improve performance regarding these three features with assistance forces computed in parallel to each other. The method was tested with simulated jerky signals and a pilot experiment with two stroke patients, who were instructed to make circular movements with an end-effector robot with assistance during half of the trials. Simulation data reveal sensitivity of the metrics for assessing the features while limiting interference between them. The assistance's effectiveness with stroke patients is established since it (i) adapts to the patient's real-time performance, (ii) improves patient motor performance, and (iii) does not lead the patient to slack. The smoothness assistance was by far the most used by both patients, while it provided no active mechanical work to the patient on average. Our performance-based assistance method for training rhythmic movements is a viable candidate to complement robot-assisted upper-limb therapies for training a larger motor repertoire.

  10. Robotic total thyroidectomy with modified radical neck dissection via unilateral retroauricular approach.

    PubMed

    Byeon, Hyung Kwon; Holsinger, F Christopher; Tufano, Ralph P; Chung, Hyo Jin; Kim, Won Shik; Koh, Yoon Woo; Choi, Eun Chang

    2014-11-01

    Traditionally, total thyroidectomy was performed through an open transcervical incision; in cases where there was evident nodal metastasis, the conventional surgical approach was to extend the incision into a large single transverse incision to complete the required neck dissection. However, recent innovation in the surgical technique of thyroidectomy has offered the opportunity to reduce the patient's burden from these prominent surgical scars in the neck. Minimally invasive surgical techniques have been developed and applied by many institutions worldwide, and more recently, various techniques of remote access surgery have been suggested and actively applied.1-6 Since the advent of robotic surgical systems, some have adopted the concept of remote access surgery into developing various robotic thyroidectomy techniques. The more former and widely acknowledged robotic thyroidectomy technique uses a transaxillary (TA) approach, which has been developed by Chung et al. in Korea.7,8 This particular technique has some limitations in the sense that accessing the lymph nodes of the central compartment is troublesome. Terris et al. realized some shortcomings of robotic TA thyroidectomy, especially in their patients in the United States, and developed and reported the feasibility of robotic facelift thyroidectomy.9-13 In cases of thyroid carcinomas with lateral neck node metastases, most abandoned the concept of minimally invasive or remote access surgery and safely adopted conventional open surgical methods to remove the tumor burden. However, Chung et al. have attempted to perform concomitant modified radical neck dissection (MRND) after robotic thyroidectomy through the same TA port.14 This type of robot-assisted neck dissection (RAND) had some inherent limitations, due to fact that lymph nodes of the upper neck were difficult to remove. Over the past few years, we have developed a RAND via modified facelift (MFL) or retroauricular (RA) approach and reported the feasibility and safety of this technique.15, 16 Since then, we have actively applied such RAND techniques in various head and neck cancers. In our country, almost all cases of robotic total thyroidectomy utilize the TA approach. According to the reports made by Terris et al., robotic facelift thyroidectomy technique has been solely applied for ipsilateral hemithyroidectomy. For total thyroidectomy, Terris et al. performed the robotic surgery with bilateral RA incisions. Here, we intend to introduce our novel surgical method after successfully attempting simultaneous robotic total thyroidectomy and RAND via a single RA approach without an axillary incision. To our knowledge, this is the first to report in the medical literature. We present four cases of our surgical experience since the beginning of 2013. All patients received robotic total thyroidectomy with MRND via single RA port without axillary incision after approval from the institutional review board at Severance Hospital, Yonsei University College of Medicine. The inclusion criteria for this operation were as follows: (1) patients with malignant carcinomas of the thyroid gland with evident cervical lymph node metastasis on preoperative imaging studies which are indicated for surgery; (2) patients with no previous history of treatment for thyroid carcinoma. The exclusion criteria were as follows: (1) patients with recurred thyroid tumors; (2) patients with thyroid carcinomas that showed gross invasion to local structures or extensive extrathyroidal capsular spread; (3) patients with clinically evident neck nodal metastasis with extracapsular spread; (4) patients with past history of neck surgery of any kind. In order to assess the extent of disease, neck ultrasonography with fine needle aspiration, neck CT or MRI and PET-CT were performed as preoperative evaluation. All patients were given full information of the possible treatment options for their thyroid cancer comprising of open transcervical approach and robotic surgery via RA approach, including the advantages and disadvantages of each treatment choice and provided written, informed consents before the surgery. General clinical information of the patients is outlined in Table 1. The skin incision for the operation was designed just like the approach for robotic facelift thyroidectomy by Terris et al. and RAND, which has been first reported by our institution.11 (,) 16 The operation was performed by the following sequence. Initially, the skin-subplatysmal flap was elevated after making the skin incision to create sufficient working space. During this process, the elevated skin flap was retracted and maintained by retractors held by the assistant. After application of the self-retaining retractor (Sangdosa Inc., Seoul), neck dissection of the upper neck levels was performed under gross vision. Next, RAND through the RA incision was conducted followed by ipsilateral thyroidectomy with central compartment neck dissection (CCND) via the same approach. Finally, contralateral thyroidectomy with CCND was performed via the single RA port. During these steps, the operator is aided by the bedside assistant with long-suction tips to manipulate and direct the dissected specimen to maintain optimal surgical view or to suck out the fume created by the thermocoagulation from the Harmonic shears. The da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) was introduced via the RA port with a facedown 30° dual-channel endoscopic arm placed in the center, and two instrument arms equipped at either side with 5-mm Maryland forceps and Harmonic curved shears. During the step of robotic contralateral thyroidectomy, a ProGrasp forceps was utilized at times, instead of 5-mm Maryland forceps. The rest of the surgery was completed with the robotic system (see Video for demonstration of operation for patient 2). Table 1 Clinical characteristics of the patients Patient Sex/age (yr) BMI Side(a) Approach Pathology(b) Tumor size(c) (cm) CCND(d) MRND(d) Drain removal day Drainage amount (ml) Hospital stay (days) 1 F/38 23.8 L RA PC 0.7 2/5 8/23 8 788 11 2 F/18 18.3 L RA PC 0.8 2/8 7/35 6 398 9 3 F/44 23.1 L RA PC 0.9 5/12 5/27 6 607 9 4 F/26 32.9 L RA PC 1.4 3/14 9/48 7 476 15 BMI body mass index, RA retroauricular approach, PC papillary carcinoma, CCND central compartment neck dissection, MRND modified radical neck dissection (a)Side refers to the site of main lesion (b)Pathology refers to the primary tumor within the thyroid gland (c)Tumor size refers to the diameter of the largest tumor in the thyroid gland (d)For each type of lymph node dissection, the number of positive nodes/total number of retrieved nodes is stated For all of the patients, robotic total thyroidectomy with MRND (levels II, III, IV, V) via unilateral RA approach was successfully completed without any significant intraoperative complications or conversion to open or other approach methods. The total operation time was defined as the time from initial skin incision to removal of the final specimen, which was an average 306.1 ± 11.1 min (Table 2). This included the time for skin flap elevation and neck dissection under gross vision (87 ± 2.8 min), setting up the robotic system for RAND (6.8 ± 2.4 min), console time using the robotic system for RAND (59.3 ± 2.2 min), flap elevation for thyroidectomy (11.3 ± 2.5 min), robotic arms docking for ipsilateral thyroidectomy (6.3 ± 2.5 min), console time for ipsilateral thyroidectomy (61.3 ± 2.1 min), robotic arms docking for contralateral thyroidectomy (6.3 ± 2.5 min), and console time for contralateral thyroidectomy (61.8 ± 2.1 min). The working space created from RA incision was sufficient, and manipulations of the robotic instruments through this approach were technically feasible and safe without any mutual collisions throughout the entire operation. It also allowed for an excellent magnified surgical view enabling visualization of important local anatomical structures. There was no postoperative vocal cord palsy due to recurrent laryngeal nerve injury. However, two patients developed transient hypoparathyroidism, which resolved in the end without the need for calcium or vitamin D supplementation after certain period of medical management (Table 3). Also, there was no incidence of postoperative hemorrhage or hematoma formation, although a single patient developed a postoperative seroma on postoperative day 9, which was managed conservatively without the need for further surgical intervention. On average, the wound catheter was removed 6.8 ± 1 days after surgery and the patient was discharged from the hospital at an average 11 ± 2.8 days from admission (Table 1). Final surgical pathology confirmed the diagnosis of papillary carcinoma for every patient. The total number of cervical nodes retrieved from CCND and MRND was 9.8 ± 4 and 33.1 ± 11 respectively, and the number of positive metastatic nodes was 3 ± 1.4 and 7.3 ± 1.7 respectively (Table 1). In three patients (patients 2, 3, and 4), the presence of one parathyroid gland was each verified in the pathology specimen. All four patients have received high-dose (150 mCi) radioiodine ablation (RAI) therapy after the operation and are being followed up (average 11.3 months, range 9-13 months) on a regular basis with no evidence of recurrence (post-RAI, most recent, nonsuppressed thyroglobulin range 0.1-0.4 ng/ml, antithyroglobulin antibody range 13.7-147.5 IU/ml). (ABSTRACT TRUNCATED)

  11. The Clinical Application of Mastectomy With Single Incision Followed by Immediate Laparoscopic-Assisted Breast Reconstruction With Latissimus Dorsi Muscle Flap.

    PubMed

    Yuan, Huozhong; Xie, Donghua; Xiao, Xigang; Huang, Xingwei

    2017-08-01

    To explore the clinical application of mastectomy with single incision followed by immediate laparoscopic-assisted breast reconstruction with latissimus dorsi muscle flap. Fifteen women with primary early breast cancer, 3 women with breast ductal carcinoma in situ, and 7 women with severe plasma cell mastitis were treated with partial mastectomy or total mastectomy, sentinel lymph node biopsy, or axillary lymph node dissection through a breast lateral transverse incision. Subsequent breast reconstruction with latissimus dorsi muscle flap was assisted by laparoscopy. The patient's position, time used in dissecting latissimus dorsi muscle flap, size of latissimus dorsi muscle flap, postoperative complications, and the cosmetic results after reconstruction were assessed. All the operations were well done through the breast lateral transverse incision and assistance of laparoscopy. The patient's position was changed only once during the operation. It took 1.5 to 2 hours to dissect latissimus dorsi muscle flap. The sizes of the latissimus dorsi muscle flap were 5 to 8 × 12 to 16 cm. There were no serious postoperative complications noted. The patients were satisfied with the appearance of the breasts and the small surgical scar. The surgical approach introduced is minimally invasive with concealed scar and outstanding cosmetic results. It is worth promoting in clinical application.

  12. Fast grasping of unknown objects using principal component analysis

    NASA Astrophysics Data System (ADS)

    Lei, Qujiang; Chen, Guangming; Wisse, Martijn

    2017-09-01

    Fast grasping of unknown objects has crucial impact on the efficiency of robot manipulation especially subjected to unfamiliar environments. In order to accelerate grasping speed of unknown objects, principal component analysis is utilized to direct the grasping process. In particular, a single-view partial point cloud is constructed and grasp candidates are allocated along the principal axis. Force balance optimization is employed to analyze possible graspable areas. The obtained graspable area with the minimal resultant force is the best zone for the final grasping execution. It is shown that an unknown object can be more quickly grasped provided that the component analysis principle axis is determined using single-view partial point cloud. To cope with the grasp uncertainty, robot motion is assisted to obtain a new viewpoint. Virtual exploration and experimental tests are carried out to verify this fast gasping algorithm. Both simulation and experimental tests demonstrated excellent performances based on the results of grasping a series of unknown objects. To minimize the grasping uncertainty, the merits of the robot hardware with two 3D cameras can be utilized to suffice the partial point cloud. As a result of utilizing the robot hardware, the grasping reliance is highly enhanced. Therefore, this research demonstrates practical significance for increasing grasping speed and thus increasing robot efficiency under unpredictable environments.

  13. Preclinical Evaluation of Robotic-Assisted Sentinel Lymph Node Fluorescence Imaging

    PubMed Central

    Liss, Michael A.; Farshchi-Heydari, Salman; Qin, Zhengtao; Hickey, Sean A.; Hall, David J.; Kane, Christopher J.; Vera, David R.

    2015-01-01

    An ideal substance to provide convenient and accurate targeting for sentinel lymph node (SLN) mapping during robotic-assisted surgery has yet to be found. We used an animal model to determine the ability of the FireFly camera system to detect fluorescent SLNs after administration of a dual-labeled molecular imaging agent. Methods We injected the footpads of New Zealand White rabbits with 1.7 or 8.4 nmol of tilmanocept labeled with 99mTc and a near-infrared fluorophore, IRDye800CW. One and 36 h after injection, popliteal lymph nodes, representing the SLNs, were dissected with the assistance of the FireFly camera system, a fluorescence-capable endoscopic imaging system. After excision of the paraaortic lymph nodes, which represented non-SLNs, we assayed all lymph nodes for radioactivity and fluorescence intensity. Results Fluorescence within all popliteal lymph nodes was easily detected by the FireFly camera system. Fluorescence within the lymph channel could be imaged during the 1-h studies. When compared with the paraaortic lymph nodes, the popliteal lymph nodes retain greater than 95% of the radioactivity at both 1 and 36 h after injection. At both doses (1.7 and 8.4 nmol), the popliteal nodes had higher (P < 0.050) optical fluorescence intensity than the paraaortic nodes at the 1- and 36-h time points. Conclusion The FireFly camera system can easily detect tilmanocept labeled with a near-infrared fluorophore at least 36 h after administration. This ability will permit image acquisition and subsequent verification of fluorescence-labeled SLNs during robotic-assisted surgery. PMID:25024425

  14. Preclinical evaluation of robotic-assisted sentinel lymph node fluorescence imaging.

    PubMed

    Liss, Michael A; Farshchi-Heydari, Salman; Qin, Zhengtao; Hickey, Sean A; Hall, David J; Kane, Christopher J; Vera, David R

    2014-09-01

    An ideal substance to provide convenient and accurate targeting for sentinel lymph node (SLN) mapping during robotic-assisted surgery has yet to be found. We used an animal model to determine the ability of the FireFly camera system to detect fluorescent SLNs after administration of a dual-labeled molecular imaging agent. We injected the footpads of New Zealand White rabbits with 1.7 or 8.4 nmol of tilmanocept labeled with (99m)Tc and a near-infrared fluorophore, IRDye800CW. One and 36 h after injection, popliteal lymph nodes, representing the SLNs, were dissected with the assistance of the FireFly camera system, a fluorescence-capable endoscopic imaging system. After excision of the paraaortic lymph nodes, which represented non-SLNs, we assayed all lymph nodes for radioactivity and fluorescence intensity. Fluorescence within all popliteal lymph nodes was easily detected by the FireFly camera system. Fluorescence within the lymph channel could be imaged during the 1-h studies. When compared with the paraaortic lymph nodes, the popliteal lymph nodes retain greater than 95% of the radioactivity at both 1 and 36 h after injection. At both doses (1.7 and 8.4 nmol), the popliteal nodes had higher (P < 0.050) optical fluorescence intensity than the paraaortic nodes at the 1- and 36-h time points. The FireFly camera system can easily detect tilmanocept labeled with a near-infrared fluorophore at least 36 h after administration. This ability will permit image acquisition and subsequent verification of fluorescence-labeled SLNs during robotic-assisted surgery. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Partial lower axillary dissection for patients with clinically node-negative breast cancer.

    PubMed

    Kodama, H; Mise, K; Kan, N

    2012-01-01

    To evaluate retrospectively the outcomes of partial lower axillary lymph node dissection caudal to the intercostobrachial nerve in patients with clinically node-negative (N(0)) breast cancer. Numbers of dissected and metastatic nodes, overall and disease-free survival rates, postoperative complication rates, and axillary recurrence were compared between patients who underwent breast cancer surgery with partial axillary node dissection (n = 1043) and historical controls who underwent conventional dissection (n = 1084). The 5-year overall and disease-free survival rates were 95.6% and 89.7%, and 94.9% and 88.4%, respectively, in the partial dissection and conventional dissection groups; the differences were not significant. Mean duration of surgery (41.6 min versus 60.9 min), intraoperative blood loss (28.0 ml versus 51.3 ml), volume of lymphatic drainage at 2 weeks postoperatively (488 ml versus 836 ml), and persistent arm lymphoedema (0.0% versus 11.8%) were significantly different between the partial and conventional dissection groups, respectively. Partial axillary lymph node dissection was associated with similar survival rates (but lower postoperative complication rates) compared with conventional axillary dissection and is recommended in patients with N(0) breast cancer.

  16. Survey of practicing urologists: robotic versus open radical prostatectomy.

    PubMed

    Lee, Eugene K; Baack, Janet; Duchene, David A

    2010-04-01

    The robotic assisted radical prostatectomy (RARP) has become the most common operative choice for localized prostate cancer. At our institution, we have also seen a substantial increase in the proportion of RARP. Possible patient factors may include marketing, increased Internet usage by patients, and patient-to-patient communication. We surveyed urologists from the central United States to determine possible surgeon factors for the popularity of the RARP. We mailed a survey to all urologists in the South Central Section of the American Urological Association. After demographic information was obtained, participants were asked to choose an operation for themselves based on two prostate cancer scenarios; low risk and high risk. For the low risk prostate cancer scenario, 54.3% chose RARP while 32.9% chose a radical retropubic prostatectomy (RRP). In the high risk scenario, 32.3% chose a RARP while 58.8% chose the RRP. The top reasons for choosing robotics included decreased blood loss, better pain control, and visualization of the apex. The most popular reasons for an open operation included improved lymph node dissection, better tactile sensation, and easier operation for the surgeon. The two most important factors for choosing a particular operation were cancer control and the urologist performing the operation. Also, urologists favored the operative choice in which he or she performed. Robotic assisted radical prostatectomy has become the favored operative approach for low risk prostate cancer. However, many urologists still feel an oncologic difference may exist between open and robotic surgery as evidenced by more urologists favoring an open approach for high risk prostate cancer.

  17. Total intracorporeal robot-assisted laparoscopic ileal conduit (Bricker) urinary diversion: technique and outcomes.

    PubMed

    Rehman, Jamil; Sangalli, Mattia N; Guru, Khurshid; de Naeyer, Geert; Schatteman, Peter; Carpentier, Paul; Mottrie, Alexander

    2011-02-01

    Several recent preliminary reports have demonstrated that Robot-Assisted Cystectomy with total intracorporeal Ileal Conduit (RACIC) is a feasible option over the open technique. We report our stepwise surgical procedure of robotic total intracorporeal ileal conduit urinary diversion, technical consideration, development, refinements and initial experience. Only the ileal conduit urinary diversion is described with no emphasis on the cystectomy's steps. Between February 2008 and September 2009, nine patients underwent RACIC for muscle invasive transitional cell carcinoma (TCC). The entire procedure, including radical cystoprostatectomy, extended pelvic node dissection (ePLND), ileal conduit urinary diversion (Bricker) including isolation of the ileal loop (20 cm ileal segment) 15 cm away from the ileocecal junction, restoration of bowel continuity with stapled side-to-side ileo-ileal anastomosis, retroperitoneal transfer of the left ureter to the right side, and bilateral stented (8 F feeding tube) ileo-ureteral anastomoses in a Wallace faction were all performed exclusively intracorporeally using the da Vinci Si surgical robot and finally the conduit stoma was fashioned. The RACIC was technically successful in all nine patients (three females and six males. Mean age 74.1; 57 to 87) without open conversion. The mean operative time including extended pelvic lymphadenectomy and urinary diversion was 346.2 minutes (210 to 480). Mean operative time of diversion is 72 minutes (52-113) mean estimated blood loss 258 mL (200 to 500) and the median hospital stay were 14 days (10 to 27). In all three female patients, the specimen was extracted through the vagina. There were no intraoperative complications and only one major postoperative complication: one postoperative iatrogenous necrosis of the ileal conduit caused by uncareful retraction of the organ bag and thereby probably injuring the conduit pedicle, as the ileal conduit was well vascularised at the end of the operation, requiring an open revision (in male patient extracted through the suprapubic incision). A clear liquid diet was started on the third postoperative day. All patients returned to normal activity within 2 weeks (from date of surgery). Postoperative renal function was normal with mean postoperative creatine 0.99 mg/dL) and excretory urography revealed unobstructed upper tracts in all cases. Robot-assisted radical cystoprostatectomy with intracorporeal ileal conduit urinary diversion for the treatment of high risk or invasive bladder cancer with urinary diversion is technically feasible. The robotic system aids in performing a meticulous dissection and all operative steps of the open procedure are replicated precisely while adhering to the sound oncologic principles of traditional radical cystectomy. Robotics brings an unprecedented control of surgical instruments, shorten the learning curve, and allow open surgeons to apply more easily their technical skill in a minimal invasive fashion. Robotic cystectomy with total intracorporeal ileal conduit urinary diversion offers operative and perioperative benefits and functional outcome. In our hands results comparable to open experience with further reduced perioperative morbidity, early recovery, resumption of normal activities, excellent cosmesis and increased quality of life (QOL). In addition, minimal blood loss, fluid shifts, and electrolyte loss considerably reduce systemic and cardiovascular stress in these older groups of patients.

  18. Comparison of a gasless unilateral axillo-breast and axillary approach in robotic thyroidectomy.

    PubMed

    Song, Chang Myeon; Cho, Yong Hee; Ji, Yong Bae; Jeong, Jin Hyeok; Kim, Dong Sun; Tae, Kyung

    2013-10-01

    New approaches to robotic thyroidectomy help to prevent neck scarring and improve surgical ergonomics. The purpose of this study was to compare the efficacy and advantages of a gasless unilateral axillary (GUA) approach and an axillo-breast (GUAB) approach in robotic thyroidectomy. We retrospectively reviewed the data of 131 patients who underwent robotic thyroidectomy with or without central neck dissection using a GUAB (90 cases) or GUA (41 cases) approach between September 2009 and December 2011. We excluded patients who underwent simultaneous lateral neck dissection and cases within the learning curve. We compared patient and tumor characteristics, surgical outcomes, perioperative complications, and cosmetic satisfaction between the two approaches. Robotic thyroidectomy was successful in all patients. There were no differences in terms of patient and tumor characteristics, extent of thyroidectomy and central neck dissection, operative time, and postoperative complications between the two approaches. Cosmetic satisfaction was excellent in both groups. There was no difference in satisfaction with the cosmetic result in the neck area, but the GUA patients expressed higher satisfaction with the appearance of the breast. The surgical outcomes of GUA and GUAB approaches are similar in robotic thyroidectomy. Both are safe, effective, and yield cosmetically excellent results when performed by an experienced robotic thyroid surgeon. However, a GUA approach is associated with superior cosmetic satisfaction with the appearance of the breast.

  19. Timing of neck dissection in patients undergoing transoral robotic surgery for head and neck cancer.

    PubMed

    Möckelmann, N; Busch, C-J; Münscher, A; Knecht, R; Lörincz, B B

    2015-06-01

    Oncologic transoral robotic surgery (TORS) requires in most cases the concurrent or staged surgical treatment of the regional lymph nodes in the neck as well. The purpose of this study was to determine whether the timing of the regional lymphadenectomy (neck dissection) has an impact on the surgical outcomes and on the complication rates. Single-institution, prospective case series with internal control group. Twenty-one patients underwent TORS and appropriate neck dissection concurrently (control group), while 20 patients underwent neck dissection in a timely staged fashion, 8.4 days (median; range, 3-28 days) following their TORS procedure (experimental group). Outcome measures included nodal yield, intraoperative pharyngocervical fistula formation, postoperative fistula formation, postoperative bleeding from the primary and from the neck dissection site, haematoma, seroma, and infection. Nodal yield values, as the oncologic quality indicator of a neck dissection, were comparable in the experimental and in the control group. Complication rates did not differ between the groups: intraoperative and postoperative fistula formation, postoperative bleeding, haematoma and seroma rates were similarly low in the two groups. There was no infection in either group. In the present cohort of 41 TORS-patients, the timing of neck dissection did not make a significant difference in the outcomes. We suggest therefore that aspiring and established TORS-teams do not restrict their appropriate indications due to robotic slot and theatre time constraints, but perform each indicated TORS-case as soon as possible within their given systems, even if the neck dissections cannot be done on the same day. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Da Vinci robot-assisted anatomic left hemihepatectomy and biliary reconstruction.

    PubMed

    Wang, Zhifei; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Zhou, Ningxin

    2013-06-01

    Since the introduction of Da Vinci robotic surgery, more and more complicated surgeries can now be performed robotically, yet there have been very few on robotic hepatectomy, especially when billiary reconstruction is involved. The video shows our initial experience with an anatomic hepatectomy using Da Vinci surgical robot. In this case, we also conducted billiary reconstruction due to the anatomic abnormality of bile duct, while applying the choledochoscopy. The preoperative diagnosis is primary liver carcinoma, tumor thrombi in bile duct, and hepatitis B. First, the gallbladder was resected, and cystic artery and duct were identified. After opening of the common bile duct above the junction, the choledochoscopy was performed. Tumor thrombi were found in common bile duct and left hepatic duct, and they were all removed. Left branches hepatic artery and portal vein were dissected, ligated, and divided. Thrombi in the left hepatic duct were removed also. After marking the cutting line along the ischemic boarder, liver parenchyma was transected using robotic harmonic scalpel. Branches of ducts were encountered and managed by either direct coagulating or dividing after clipping. The left hepatic vein was visualized, exposed, and divided during hepatectomy. Two T tubes were placed into common hepatic duct and the proximal cutting end of right anterior bile duct which was found to join the left hepatic duct, respectively. The operation went on successfully. The operation time was 410 minutes, the blood loss was 200 mL. The pathologic diagnosis was introductal papillary adenocarcinoma of left hepatic duct. The patient went on well postoperatively and was followed up for 22 months till now. Postoperative computed tomography examination showed no recurrence. Da Vinci-assisted robotic hepatectomy can be performed safely in the hands of experienced hepatobilliary surgeons, and choledochoscopy can be combined for bile duct exploration. With the advantages of Da Vinci robot system, complicated billiary reconstruction can be performed (http://links.lww.com/SLE/A74).

  1. Applications of Evolving Robotic Technology for Head and Neck Surgery.

    PubMed

    Sharma, Arun; Albergotti, W Greer; Duvvuri, Umamaheswar

    2016-03-01

    Assess the use and potential benefits of a new robotic system for transoral radical tonsillectomy, transoral supraglottic laryngectomy, and retroauricular thyroidectomy in a cadaver dissection. Three previously described robotic procedures (transoral radical tonsillectomy, transoral supraglottic laryngectomy, and retroauricular thyroidectomy) were performed in a cadaver using the da Vinci Xi Surgical System. Surgical exposure and access, operative time, and number of collisions were examined objectively. The new robotic system was used to perform transoral radical tonsillectomy with dissection and preservation of glossopharyngeal nerve branches, transoral supraglottic laryngectomy, and retroauricular thyroidectomy. There was excellent exposure without any difficulties in access. Robotic operative times (excluding set-up and docking times) for the 3 procedures in the cadaver were 12.7, 14.3, and 21.2 minutes (excluding retroauricular incision and subplatysmal elevation), respectively. No robotic arm collisions were noted during these 3 procedures. The retroauricular thyroidectomy was performed using 4 robotic ports, each with 8 mm instruments. The use of updated and evolving robotic technology improves the ease of previously described robotic head and neck procedures and may allow surgeons to perform increasingly complex surgeries. © The Author(s) 2015.

  2. The learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease.

    PubMed

    Novotný, Tomáš; Dvorák, Martin; Staffa, Robert

    2011-02-01

    Since the end of the 20th century, robot-assisted surgery has been finding its role among other minimally invasive methods. Vascular surgery seems to be another specialty in which the benefits of this technology can be expected. Our objective was to assess the learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease in a group of 40 patients. Between May 2006 and January 2010, 40 patients (32 men, 8 women), who were a median age of 58 years (range, 48-75 years), underwent 40 robot-assisted laparoscopic aortofemoral reconstructions. Learning curve estimations were used for anastomosis, clamping, and operative time assessment. For conversion rate evaluation, the cumulative summation (CUSUM) technique was used. Statistical analysis comparing the first and second half of our group, and unilateral-to-bilateral reconstructions were performed. We created 21 aortofemoral and 19 aortobifemoral bypasses. The median proximal anastomosis time was 23 minutes (range, 18-50 minutes), median clamping time was 60 minutes (range, 40-95 minutes), and median operative time was 295 minutes (range, 180-475 minutes). The 30-day mortality rate was 0%, and no graft or wound infection or cardiopulmonary or hepatorenal complications were observed. During the median 18-month follow-up (range, 2-48 months), three early graft occlusions occurred (7%). After reoperations, the secondary patency of reconstructions was 100%. Data showed a typical short learning curve for robotic proximal anastomosis creation with anastomosis and clamping time reduction. The operative time learning curve was flat, confirming the procedure's complexity. There were two conversions to open surgery. CUSUM analysis confirmed that an acceptable conversion rate set at 5% was achieved. Comparing the first and second half of our group, all recorded times showed statistically significant improvements. Differences between unilateral and bilateral reconstructions were not statistically significant. Our results show that the success rate of robot-assisted laparoscopic aortofemoral bypass grafting is high and the complication rate is low. Anastomosis creation, one of the main difficulties of laparoscopic bypass grafting, has been overcome using the robotic operating system and its learning curve is short. However, the endoscopic dissection of the aortoiliac segment remains the most difficult part of the operation and should be addressed in further development of the method to reduce the operative times. Long-term results and potential benefits of this minimally invasive method have to be verified by randomized controlled clinical trials. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  3. Development and validation of surgical training tool: cystectomy assessment and surgical evaluation (CASE) for robot-assisted radical cystectomy for men.

    PubMed

    Hussein, Ahmed A; Sexton, Kevin J; May, Paul R; Meng, Maxwell V; Hosseini, Abolfazl; Eun, Daniel D; Daneshmand, Siamak; Bochner, Bernard H; Peabody, James O; Abaza, Ronney; Skinner, Eila C; Hautmann, Richard E; Guru, Khurshid A

    2018-04-13

    We aimed to develop a structured scoring tool: cystectomy assessment and surgical evaluation (CASE) that objectively measures and quantifies performance during robot-assisted radical cystectomy (RARC) for men. A multinational 10-surgeon expert panel collaborated towards development and validation of CASE. The critical steps of RARC in men were deconstructed into nine key domains, each assessed by five anchors. Content validation was done utilizing the Delphi methodology. Each anchor was assessed in terms of context, score concordance, and clarity. The content validity index (CVI) was calculated for each aspect. A CVI ≥ 0.75 represented consensus, and this statement was removed from the next round. This process was repeated until consensus was achieved for all statements. CASE was used to assess de-identified videos of RARC to determine reliability and construct validity. Linearly weighted percent agreement was used to assess inter-rater reliability (IRR). A logit model for odds ratio (OR) was used to assess construct validation. The expert panel reached consensus on CASE after four rounds. The final eight domains of the CASE included: pelvic lymph node dissection, development of the peri-ureteral space, lateral pelvic space, anterior rectal space, control of the vascular pedicle, anterior vesical space, control of the dorsal venous complex, and apical dissection. IRR > 0.6 was achieved for all eight domains. Experts outperformed trainees across all domains. We developed and validated a reliable structured, procedure-specific tool for objective evaluation of surgical performance during RARC. CASE may help differentiate novice from expert performances.

  4. Social Robotics in Therapy of Apraxia of Speech

    PubMed Central

    Alonso-Martín, Fernando

    2018-01-01

    Apraxia of speech is a motor speech disorder in which messages from the brain to the mouth are disrupted, resulting in an inability for moving lips or tongue to the right place to pronounce sounds correctly. Current therapies for this condition involve a therapist that in one-on-one sessions conducts the exercises. Our aim is to work in the line of robotic therapies in which a robot is able to perform partially or autonomously a therapy session, endowing a social robot with the ability of assisting therapists in apraxia of speech rehabilitation exercises. Therefore, we integrate computer vision and machine learning techniques to detect the mouth pose of the user and, on top of that, our social robot performs autonomously the different steps of the therapy using multimodal interaction. PMID:29713440

  5. Early impact of robot-assisted partial nephrectomy on renal function as assessed by renal scintigraphy.

    PubMed

    Luciani, Lorenzo G; Chiodini, Stefano; Donner, Davide; Cai, Tommaso; Vattovani, Valentino; Tiscione, Daniele; Giusti, Guido; Proietti, Silvia; Chierichetti, Franca; Malossini, Gianni

    2016-06-01

    To measure the early impact of robot-assisted partial nephrectomy (RAPN) on renal function as assessed by renal scan (Tc 99m-DTPA), addressing the issue of risk factors for ischemic damage to the kidney. All patients undergoing RAPN for cT1 renal masses between June 2013 and May 2014 were included in this prospective study. Renal function as expressed by glomerular filtration rate (GFR) was assessed by Technetium 99m-diethylenetriaminepentaacetic acid (Tc 99m-DTPA) renal scan preoperatively and postoperatively at 1 month in every patient. A multivariable analysis was used for the determination of independent factors predictive of GFR decrease of the operated kidney. Overall, 32 patients underwent RAPN in the time interval. Median tumor size, blood loss, and ischemia time were 4 cm, 200 mL, and 24 min, respectively. Two grade III complications occurred (postoperative bleeding in the renal fossa, urinoma). The GFR of the operated kidney decreased significantly from 51.7 ± 15.1 mL/min per 1.73 m(2) preoperatively to 40, 12 ± 12.4 mL/min per 1.73 m(2) 1 month postoperatively (p = 0.001) with a decrease of 22.4 %. On multivariable analysis, only tumor size (p = 0.05) was a predictor of GFR decrease of the operated kidney. Robotic-assisted partial nephrectomy had a detectable impact on early renal function in a series of relatively large tumors and prevailing intermediate nephrometric risk. A mean decrease of 22 % of GFR as assessed by renal scan in the operated kidney was found at 1 month postoperatively. In multivariable analysis, tumor size only was a significant predictor of renal function loss.

  6. Transvaginal endoscopic partial gastrectomy in porcine models: the role of an extra endoscope for gastric control.

    PubMed

    Nakajima, Kiyokazu; Takahashi, Tsuyoshi; Souma, Yoshihito; Shinzaki, Shinichiro; Yamada, Takuya; Yoshio, Toshiyuki; Nishida, Toshirou

    2008-12-01

    Transvaginal natural orifice translumenal endoscopic surgery (NOTES) gastrectomy is technically challenging, because wide perigastric dissection under appropriate tissue triangulation is unfeasible with current endoscopic instruments alone. The aim of this study was to investigate the feasibility of transvaginal NOTES gastrectomy with the use of an extra endoscope as a retracting device of the stomach. This acute in vivo feasibility study was performed under the approval of the Institutional Animal Care and Use Committee (IACUC). Four female 40-kg pigs received general anesthesia and underwent transvaginal endoscopic partial gastrectomy. Under laparoscopic guidance, the uterus was fixed anteriorly and transvaginal access was established in a standard fashion. The perigastric ligaments were dissected with needle knife/insulation-tipped electrosurgical knife (IT) via transvaginally placed double-channel endoscope. This step was assisted with the second, CO(2)-insufflating endoscope advanced in the stomach (i.e., so-called endoscopic gastric control). A linear stapling device with a flexible shaft was then passed transvaginally, and the anterior gastric wall was partially resected. The specimen was isolated and retrieved through the vagina. Concluding endoscopy was carried out to confirm the absence of mucosal damage due to endoscopic gastric control. This was further confirmed at necropsy immediately after sacrifice. All animals underwent successful transvaginal NOTES gastrectomy. Endoscopic gastric control greatly facilitated perigastric dissection by providing appropriate tissue countertraction on the ligaments. Use of transabdominal (laparoscopic) graspers was thus minimized. There were no intraoperative complications directly related to use of the primary (transvaginal) endoscope or the additional (gastric) endoscope. Distention of downstream bowel after gastric insufflation was minimal with CO(2). No major injuries were noted on gastric mucosa at postmortem investigations. Transvaginal NOTES partial gastrectomy is feasible in porcine models. Use of an extra endoscope to retract the stomach is effective to minimize transabdominal assistance. Further studies on human subjects are necessary to establish this as a safe and attractive ancillary technique in NOTES.

  7. Robotic Cholecystectomy Using the Newly Developed Korean Robotic Surgical System, Revo-i: A Preclinical Experiment in a Porcine Model.

    PubMed

    Kang, Chang Moo; Chong, Jae Uk; Lim, Jin Hong; Park, Dong Won; Park, Sung Jun; Gim, Suhyeon; Ye, Hye Jin; Kim, Se Hoon; Lee, Woo Jung

    2017-09-01

    One Korean company recently successfully produced a robotic surgical system prototype called Revo-i (MSR-5000). We, therefore, conducted a preclinical study for robotic cholecystectomy using Revo-i, and this is a report of the first case of robotic cholecystectomy performed using the Revo-i system in a preclinical porcine model. Revo-i consists of a surgeon console (MSRC-5000), operation cart (MSRO-5000) and vision cart (MSRV-5000), and a 40 kg-healthy female porcine was prepared for robotic cholecystectomy with general anesthesia. The primary end point was the safe completion of these procedures using Revo-i: The total operation time was 88 minutes. The dissection time was defined as the time from the initial dissection of the Calot area to the time to complete gallbladder detachment from the liver bed: The dissection time required 14 minutes. The surgical console time was 45 minutes. There was no gallbladder perforation or significant bleeding noted during the procedure. The porcine survived for two weeks postoperatively without any complications. Like the da Vinci surgical system, the Revo-i provides a three-dimensional operative view and allows for angulated instrument motion (forceps, needle-holders, clip-appliers, scissors, bipolar energy, and hook monopolar energy), facilitating an effective laparoscopic procedure. Our experience suggests that robotic cholecystectomy can be safely completed in a porcine model using Revo-i. © Copyright: Yonsei University College of Medicine 2017.

  8. Quantification of loading in biomechanical testing: the influence of dissection sequence.

    PubMed

    Funabashi, Martha; El-Rich, Marwan; Prasad, Narasimha; Kawchuk, Gregory N

    2015-09-18

    Sequential dissection is a technique used to investigate loads experienced by articular tissues. When the joint of interest is tested in an unconstrained manner, its kinematics change with each tissue removal. To address this limitation, sufficiently rigid robots are used to constrain joint kinematics. While this approach can quantify loads experienced by each tissue, it does not assure similar results when removal order is changed. Specifically, structure loading is assumed to be independent of removal order if the structure behaves linearly (i.e. principle of superposition applies), but dependent on removal order when response is affected by material and/or geometry nonlinearities and/or viscoelasticiy (e.g. biological tissues). Therefore, this experiment was conducted to evaluate if structure loading created through robotic testing is dependent on the order in which connectors are removed. Six identical models were 3D printed. Each model was composed of 2 rigid bodies and 3 connecting structures with nonlinear time-dependent behavior. To these models, pure rotations were applied about a predefined static center of rotation using a parallel robot. A unique dissection sequence was used for each of the six models and the same movements applied robotically after each dissection. When comparing the moments experienced by each structure between different removal sequences, a statistically significant difference (p<0.05) was observed. These results suggest that even in an optimized environment, the sequence in which nonlinear viscoelastic structures are removed influence model loading. These findings support prior work suggesting that tissue loads obtained from robotic testing are specific to removal order. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Transoral robotic thyroidectomy: a preclinical feasibility study using the da Vinci Xi platform.

    PubMed

    Russell, Jonathon O; Noureldine, Salem I; Al Khadem, Mai G; Chaudhary, Hamad A; Day, Andrew T; Kim, Hoon Yub; Tufano, Ralph P; Richmon, Jeremy D

    2017-09-01

    Transoral thyroid surgery allows the surgeon to conceal incisions within the oral cavity without significantly increasing the amount of required dissection. TORT provides an ideal scarless, midline access to the thyroid gland and bilateral central neck compartments. This approach, however, presents multiple technical challenges. Herein, we present our experience using the latest generation robotic surgical system to accomplish transoral robotic thyroidectomy (TORT). In two human cadavers, the da Vinci Xi surgical system (Intuitive Surgical, Sunnyvale, CA, USA) was used to complete TORT. Total thyroidectomy and bilateral central neck dissection was successfully completed in both cadavers. The da Vinci Xi platform offered several technologic advantages over previous robotic generations including overhead docking, narrower arms, and improved range of motion allowing for improved execution of previously described TORT techniques.

  10. Towards cybernetic surgery: robotic and augmented reality-assisted liver segmentectomy.

    PubMed

    Pessaux, Patrick; Diana, Michele; Soler, Luc; Piardi, Tullio; Mutter, Didier; Marescaux, Jacques

    2015-04-01

    Augmented reality (AR) in surgery consists in the fusion of synthetic computer-generated images (3D virtual model) obtained from medical imaging preoperative workup and real-time patient images in order to visualize unapparent anatomical details. The 3D model could be used for a preoperative planning of the procedure. The potential of AR navigation as a tool to improve safety of the surgical dissection is outlined for robotic hepatectomy. Three patients underwent a fully robotic and AR-assisted hepatic segmentectomy. The 3D virtual anatomical model was obtained using a thoracoabdominal CT scan with a customary software (VR-RENDER®, IRCAD). The model was then processed using a VR-RENDER® plug-in application, the Virtual Surgical Planning (VSP®, IRCAD), to delineate surgical resection planes including the elective ligature of vascular structures. Deformations associated with pneumoperitoneum were also simulated. The virtual model was superimposed to the operative field. A computer scientist manually registered virtual and real images using a video mixer (MX 70; Panasonic, Secaucus, NJ) in real time. Two totally robotic AR segmentectomy V and one segmentectomy VI were performed. AR allowed for the precise and safe recognition of all major vascular structures during the procedure. Total time required to obtain AR was 8 min (range 6-10 min). Each registration (alignment of the vascular anatomy) required a few seconds. Hepatic pedicle clamping was never performed. At the end of the procedure, the remnant liver was correctly vascularized. Resection margins were negative in all cases. The postoperative period was uneventful without perioperative transfusion. AR is a valuable navigation tool which may enhance the ability to achieve safe surgical resection during robotic hepatectomy.

  11. Robot-Assisted Mckeown Esophagectomy is Feasible After Neoadjuvant Chemoradiation. Our Initial Experience.

    PubMed

    Goel, Ashish; Shah, Swati H; Selvakumar, Veda Padma Priya; Garg, Shubha; Kumar, Kapil

    2018-02-01

    Neoadjuvant chemoradiation has become the standard of care for esophageal cancer, especially for middle third esophageal lesions and those with squamous histology. Although more and more thoracic surgeons and surgical oncologists have now shifted to video-assisted and robot-assisted thoracoscopic esophagectomy; there is still limited experience for the use of minimal-assisted approaches in patients undergoing surgery after neoadjuvant chemoradiation. Most surgeons have concerns of feasibility, safety, and oncological outcomes as well as issues related to difficult learning curve in adopting robotic esophagectomy in patients after chemoradiation. We present our initial experience of Robot-Assisted Mckeown Esophagectomy in 27 patients after neoadjuvant chemoradiation, from May 2013 to October 2014. All patients underwent neoadjuvant chemoradiation to a dose of 50.4 Gy/25Fr with concurrent weekly cisplatin, followed by reassessment with clinical examination and repeat FDG PET/CT 6 weeks after completion of chemoradiation. Patients with progressive disease underwent palliative chemotherapy while patients with either partial or significant response to chemoradiation underwent Robot-Assisted Mckeown Esophagectomy with esophageal replacement by gastric conduit and esophagogastric anastomosis in the left neck. Out of 27 patients, 92.5 % patients had stage cT3/T4 tumours and node-positive disease in 48.1 % on imaging. Most patients were middle thoracic esophageal cancers (23/27), with squamous histology in all except for one. All patients received neoadjuvant chemoradiation and subsequently underwent Robot Assisted Mckeown Esophagectomy. The average time for robot docking, thoracic mobilization and total surgical procedure was 13.2, 108.4 and 342.7 min, respectively. The procedure was well tolerated by all patients with only one case of peri-operative mortality. Average ICU stay was 6.35 days (range 3-9 days). R0 resection rate of 96.3 % and average lymph node yield of 18 could be achieved. Pathological node negativity rate (pN0) and complete response (pCR) were 66.6 and 44.4 %, respectively. In the initial cases, four patients had to be converted to open due technical reasons or intraoperative complications. The present study, with shorter operative times, similar ICU stay, overall low morbidity, and mortality and optimal oncological outcomes suggest that robot-assisted thoracic mobilization of esophagus in patients with prior chemoradiation is feasible and safe with acceptable oncological outcomes. It has a shorter learning curve and hence allows for a transthoracic minimally invasive transthoracic esophagectomy to more and more patients, otherwise unfit for conventional approach.

  12. Robot-assisted Partial Nephrectomy: 5-yr Oncological Outcomes at a Single European Tertiary Cancer Center.

    PubMed

    Vartolomei, Mihai Dorin; Matei, Deliu Victor; Renne, Giuseppe; Tringali, Valeria Maria; Crisan, Nicolae; Musi, Gennaro; Mistretta, Francesco Alessandro; Russo, Andrea; Cozzi, Gabriele; Cordima, Giovani; Luzzago, Stefano; Cioffi, Antonio; Di Trapani, Ettore; Catellani, Michele; Delor, Maurizio; Bottero, Danilo; Imbimbo, Ciro; Mirone, Vincenzo; Ferro, Matteo; de Cobelli, Ottavio

    2017-10-27

    Nowadays, there is a debate about which surgical treatment should be best for clinical T1 renal tumors. If the oncological outcomes are considered, there are many open and laparoscopic series published. As far as robotic series are concerned, only a few of them report 5-yr oncological outcomes. The aim of this study was to analyze robot-assisted partial nephrectomy (RAPN) midterm oncological outcomes achieved in a tertiary robotic reference center. Between April 2009 and September 2013, 123 consecutive patients with clinical T1-stage renal masses underwent RAPN in our tertiary cancer center. Inclusion criteria were as follows: pathologically confirmed renal cell carcinomas (RCCs) and follow-up for >12 mo. Eighteen patients were excluded due to follow-up of <12 mo and 15 due to benign final pathology. Median follow-up was 59 mo (interquartile range 44-73 mo). Patients were followed according to guideline recommendations and institutional protocol. Outcomes were measured by time to disease progression, overall survival, or time to cancer-specific death. Kaplan-Meier method was used to estimate survival; log-rank tests were applied for pair-wise comparison of survival. From the 90 patients included, 66 (73.3%) had T1a, 12 (13.3%) T1b, three (3.3%) T2a, and nine (10%) T3a tumors. Predominant histological type was clear cell carcinoma: 67 (74.5%). Fuhrmann grade 1 and 2 was found in 73.3% of all malignant tumors. Two patients (2.2%) had positive surgical margins, and complication rate was 17.8%. Relapse rate was 7.7%, including two cases (2.2%) of local recurrences and five (5.5%) distant metastasis. Five-year disease-free survival was 90.9%, 5-yr cancer-specific survival was 97.5%, and 5-yr overall survival was 95.1%. Midterm oncological outcomes after RAPN for localized RCCs (predominantly T1a tumors of low anatomic complexity) were shown to be good, adding significant evidence to support the oncological efficacy and safety of RAPN for the treatment of this type of tumors. Robot-assisted partial nephrectomy seems to be the most promising minimally invasive approach in the treatment of renal masses suitable for organ-sparing surgery as midterm (5 yr) oncological outcomes are excellent. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  13. Could laser-assisted dissection of the pre-epiglottic space affect functional outcome after ESL?

    PubMed

    Bertolin, Andy; Lionello, Marco; Russo, Simone; Rizzotto, Giuseppe; Lucioni, Marco

    2018-06-01

    To evaluate the effect of preepiglottic space (PES) dissection in the endoscopic supraglottic laryngectomy (ESL). A retrospective cohort study. We retrospectively compared 15 patients who underwent ESL with 15 patients matched for clinical stage who underwent open partial horizontal laryngectomy (OPHL). The functional outcomes were assessed in terms of hospital stay; need for nasal feeding tube (NFT) and tracheostomy, as well as duration of their use; postoperative complications; aspiration pneumonia rates; voice quality; and dysphagia. Among the ESL cases, combined dissection of the epiglottis and PES (type III) had a negative impact on functional outcomes. ESL patients experienced shorter hospital stays, as well as shorter use of NFT and tracheostomy, than patients who had OPHL. Combined dissection of the epiglottis and PES (ESL type III) negatively affected functional outcome in patients undergoing ESL, a procedure generally related to significantly better functional outcomes than OPHL type I. 4. Laryngoscope, 128:1371-1378, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Outcomes of Robot-assisted Partial Nephrectomy for Clinical T2 Renal Tumors: A Multicenter Analysis (ROSULA Collaborative Group).

    PubMed

    Bertolo, Riccardo; Autorino, Riccardo; Simone, Giuseppe; Derweesh, Ithaar; Garisto, Juan D; Minervini, Andrea; Eun, Daniel; Perdona, Sisto; Porter, James; Rha, Koon Ho; Mottrie, Alexander; White, Wesley M; Schips, Luigi; Yang, Bo; Jacobsohn, Kenneth; Uzzo, Robert G; Challacombe, Ben; Ferro, Matteo; Sulek, Jay; Capitanio, Umberto; Anele, Uzoma A; Tuderti, Gabriele; Costantini, Manuela; Ryan, Stephen; Bindayi, Ahmet; Mari, Andrea; Carini, Marco; Keehn, Aryeh; Quarto, Giuseppe; Liao, Michael; Chang, Kidon; Larcher, Alessandro; De Naeyer, Geert; De Cobelli, Ottavio; Berardinelli, Francesco; Zhang, Chao; Langenstroer, Peter; Kutikov, Alexander; Chen, David; De Luyk, Nicolo; Sundaram, Chandru P; Montorsi, Francesco; Stein, Robert J; Haber, Georges Pascal; Hampton, Lance J; Dasgupta, Prokar; Gallucci, Michele; Kaouk, Jihad; Porpiglia, Francesco

    2018-05-18

    While partial nephrectomy (PN) represents the standard surgical management for cT1 renal masses, its role for cT2 tumors is controversial. Robot-assisted PN (RAPN) is being increasingly implemented worldwide. To analyze perioperative, functional, and oncological outcomes of RAPN for cT2 tumors. Retrospective analysis of a large multicenter, multinational dataset of patients with nonmetastatic cT2 masses treated with robotic surgery (ROSULA: RObotic SUrgery for LArge renal mass). Robotic-assisted PN. Patients' demographics, lesion characteristics, perioperative variables, renal functional data, pathology, and oncological data were analyzed. Univariable and multivariable regression analyses assessed the relationships with the risk of intra-/postoperative complications, recurrence, and survival. A total of 298 patients were analyzed. Median tumor size was 7.6 (7-8.5) cm. Median RENAL score was 9 (8-10). Median ischemia time was 25 (20-32) min. Median estimated blood loss was 150 (100-300) ml. Sixteen patients had intraoperative complications (5.4%), whereas 66 (22%) had postoperative complications (5% were Clavien grade ≥3). Multivariable analysis revealed that a lower RENAL score (odds ratio [OR] 0.46, 95% confidence interval [CI] 0.21-0.65, p=0.02) and pathological pT2 stage (OR 0.51, 95% CI 0.12-0.86, p=0.001) were protective against postoperative complications. A total of 243 lesions (82%) were malignant. Twenty patients (8%) had positive surgical margins. Ten deaths and 25 recurrences/metastases occurred at a median follow-up of 12 (5-35) mo. At univariable analysis, higher pT stage was predictive of a likelihood of recurrences/metastases (p=0.048). While there was a significant deterioration of renal function at discharge, this remained stable over time at 1-yr follow-up. The main limitation of this study is its retrospective design. RAPN in the setting of select cT2 renal masses can safely be performed with acceptable outcomes. Further studies are warranted to corroborate our findings and to better define the role of robotic nephron sparing for this challenging indication. This report shows that robotic surgery can be used for safe removal of a large renal tumor in a minimally invasive fashion, maximizing preservation of renal function, and without compromising cancer control. Published by Elsevier B.V.

  15. Port positioning and docking for single-stage totally robotic dissection for rectal cancer surgery with the Si and Xi Da Vinci Surgical System.

    PubMed

    Toh, James Wei Tatt; Kim, Seon-Hahn

    2017-11-04

    We have previously reported our technique of single-docking totally robotic dissection for rectal cancer surgery using the Da Vinci ® Si Surgical System in 2009. However, we have since optimised our port placement for the Si system and have developed a novel configuration of port placement and docking for the Da Vinci ® Xi Surgical System. We have performed over 700 cases using this technique with the Si system and have used our Xi technique since 2016 for totally robotic dissection for rectal cancer. We have kept the configuration of port placements for both the Xi and Si system as similar as possible, with the priorities to avoid arm collisions as well as to provide a workable port configuration of two left-handed instruments and one right-handed instrument. To date, there have had no major complications or arm collisions related to this technique of docking, port positioning and instrument placement.

  16. Deep Infiltrating Colorectal Endometriosis Treated With Robotic-Assisted Rectosigmoidectomy

    PubMed Central

    Schraibman, Vladimir; Okazaki, Samuel; Maccapani, Gabriel; Chen, Winston Jenning; Domit, Cassia Danielle; Kaufmann, Oskar Grau; Advincula, Arnold P.

    2013-01-01

    Background and Objective: Deep infiltrating pelvic endometriosis with bowel involvement is one of the most aggressive forms of endometriosis. Nowadays, robotic technology and telemanipulation systems represent the latest developments in minimally invasive surgery. The aim of this study is to present our preliminary results and evaluate the feasibility of robotic-assisted laparoscopic colorectal resection for severe endometriosis. Methods: Between September 2009 and December 2011, 10 women with colorectal endometriosis underwent surgery with the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA, USA). We evaluated the following parameters: short-term complications, clinical outcomes and long-term follow-up, pain relief recurrence rate, and fertility outcomes. Results: Extensive ureterolysis was required in 8 women (80%). Ovarian cystectomy with removal of the cystic wall was performed in 7 women (70%). Torus resection was performed in all women, with unilateral and bilateral uterosacral ligament resection in 1 woman (10%) and 8 women (80%), respectively. In addition to segmental colorectal resection in all cases, partial vaginal resection was necessary in 2 women (20%). An appendectomy was performed in 2 patients (20%). The mean operative time with the robot was 157 minutes (range, 90–190 minutes). The mean hospital stay was 3 days. Six patients had infertility before surgery, with a mean infertility time of 2 years. After a 12-month follow-up period, 4 women (67%) conceived naturally and 2 (33%) underwent in vitro fertilization. Conclusion: We show that robotic-assisted laparoscopic surgery for the treatment of deep infiltrating bowel endometriosis is feasible, effective, and safe. PMID:23925016

  17. Value of Nephrometry Score Constituents on Perioperative Outcomes and Split Renal Function in Patients Undergoing Minimally Invasive Partial Nephrectomy.

    PubMed

    Watts, Kara L; Ghosh, Propa; Stein, Solomon; Ghavamian, Reza

    2017-01-01

    To assess the relationship between individual nephrometry score (NS) constituents (RENAL) on perioperative outcomes and renal function of the surgical kidney in patients undergoing laparoscopic partial nephrectomy or robotic-assisted partial nephrectomy. Two hundred forty-five patients who underwent laparoscopic partial nephrectomy or robotic-assisted partial nephrectomy between 2005 and 2014 were retrospectively reviewed. Each renal mass' NS was calculated from preoperative computed tomography imaging. Multivariate regression analysis was used to evaluate the effect of NS variables on perioperative outcomes and change in overall renal function (as estimated by glomerular filtration rate) from preoperative to 1-year postoperative. A cohort analysis assessed the effect of NS variables on change in split renal function of the surgical kidney from pre- to postoperative based on nuclear medicine renal scintigraphy. Tumor radius (R), endophytic nature (E), and nearness to collecting system (N) variables significantly and incrementally predicted a longer operative time and warm ischemia time. Overall renal function based on glomerular filtration rate was not affected by any NS variable. However, percent function of the surgical kidney by renal scintigraphy significantly decreased postoperatively as R and E values increased. R, E, and N were associated with significant changes in warm ischemia time and operative time. R and E were associated with a significant decrease in split renal function of the surgical kidney at 1 year after surgery but not with overall renal function. R, E, and N are the NS constituents most relevant to perioperative outcomes and postoperative differential renal function after partial nephrectomy. Copyright © 2016. Published by Elsevier Inc.

  18. KineAssist: design and development of a robotic overground gait and balance therapy device.

    PubMed

    Patton, James; Brown, David A; Peshkin, Michael; Santos-Munné, Julio J; Makhlin, Alex; Lewis, Ela; Colgate, Edward J; Schwandt, Doug

    2008-01-01

    Balance and mobility training consists of activities that carry a high risk for falling. The purpose of this article is to describe a novel robotic system for allowing challenging, yet safe, balance and mobility training in persons at high risk for falls. With no initial preconceptions of what device we would build, a user-needs analysis led us to focus on increasing the level of challenge to a patient's ability to maintain balance during gait training and also on maintaining direct involvement of a physical therapist (rather than attempting robotic replacement). The KineAssist is a robotic device for gait and balance training that has emerged from a unique design process of a start-up product of a small company and a team of therapists, engineers, mechanical design experts, and rehabilitation scientists. The KineAssist provides partial body weight support and postural control on the torso; allows many axes of motion of the trunk and pelvis; leaves the patient's legs accessible to a physical therapist's manipulation during walking; follows a patient's walking motions overground in forward, rotation, and sidestepping directions; and catches an individual who loses balance and begins to fall. Design and development of the KineAssist proceeded more rapidly in the context of a small company than would have been possible in most institutional research contexts. A prototype KineAssist has been constructed and has received US Food and Drug Administration (FDA) classification and institutional review board clearance for initial human studies. The acceptance of KineAssist will ultimately depend on improved patient outcomes, the use of this new tool by therapists, the ease of use of the system, and the recognition of the unique value it brings to therapeutic recovery.

  19. Robotic retroperitoneal partial nephrectomy: a step-by-step guide.

    PubMed

    Ghani, Khurshid R; Porter, James; Menon, Mani; Rogers, Craig

    2014-08-01

    To describe a step-by-step guide for successful implementation of the retroperitoneal approach to robotic partial nephrectomy (RPN) PATIENTS AND METHODS: The patient is placed in the flank position and the table fully flexed to increase the space between the 12th rib and iliac crest. Access to the retroperitoneal space is obtained using a balloon-dilating device. Ports include a 12-mm camera port, two 8-mm robotic ports and a 12-mm assistant port placed in the anterior axillary line cephalad to the anterior superior iliac spine, and 7-8 cm caudal to the ipsilateral robotic port. Positioning and port placement strategies for successful technique include: (i) Docking robot directly over the patient's head parallel to the spine; (ii) incision for camera port ≈1.9 cm (1 fingerbreadth) above the iliac crest, lateral to the triangle of Petit; (iii) Seldinger technique insertion of kidney-shaped balloon dilator into retroperitoneal space; (iv) Maximising distance between all ports; (v) Ensuring camera arm is placed in the outer part of the 'sweet spot'. The retroperitoneal approach to RPN permits direct access to the renal hilum, no need for bowel mobilisation and excellent visualisation of posteriorly located tumours. © 2014 The Authors. BJU International © 2014 BJU International.

  20. Robotic surgery

    MedlinePlus

    Robot-assisted surgery; Robotic-assisted laparoscopic surgery; Laparoscopic surgery with robotic assistance ... computer station and directs the movements of a robot. Small surgical tools are attached to the robot's ...

  1. Transoral robotic surgery for neurogenic tumors of the prestyloid parapharyngeal space.

    PubMed

    Lee, Hyoung Shin; Kim, Jinna; Lee, Hyun Jin; Koh, Yoon Woo; Choi, Eun Chang

    2012-08-01

    The parapharyngeal space is a difficult area for a surgical approach due to anatomical complexity. We performed a minimally invasive and precise surgical technique to remove neurogenic tumors of the prestyloid parapharyngeal space using transoral robotic instrumentation. The mass was successfully removed in the two cases with three-dimensional visualization providing an excellent view of the resection margin and the dissection plane preserving the vital structures. An adequate resection margin was acquired, and no violation of the tumor capsule occurred. No significant complications were noted. Transoral robotic surgery was feasible for neurogenic tumors of the prestyloid parapharyngeal space, providing a sufficient resection margin and delicate dissection through excellent surgical views and instrumentation. Copyright © 2012. Published by Elsevier Ireland Ltd.

  2. Delayed Partial Nephrectomy for Hydronephrosis After Renal Trauma.

    PubMed

    Setia, Shaan; Jackson, Jessica Nicole; Herndon, C D Anthony; Corbett, Sean T

    2017-03-01

    Delayed sequelae following conservative management of renal trauma in the pediatric population are uncommon. Reports of delayed operations to manage these sequelae are even less common. Here we present the case of a 16-year-old male patient who had delayed development of upper urinary tract obstruction with recurrent infections following high-grade renal trauma managed conservatively. Ultimately, he required a robotic-assisted partial nephrectomy 2 years after initial nonoperative management. This is unique as no prior studies to our knowledge have described delayed hydronephrosis and delayed partial nephrectomy over a year following renal trauma. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Robotic Y-V Plasty for Recalcitrant Bladder Neck Contracture.

    PubMed

    Granieri, Michael A; Weinberg, Aaron C; Sun, Jeffrey Y; Stifleman, Michael; Zhao, Lee

    2018-07-01

    To demonstrate the technique and the outcomes of robot assisted Y-V plasty bladder neck reconstruction (RYVBNR). We present our technique for treatment of recalcitrant bladder neck contracture (BNC) in 7 patients who underwent RYVBNR at our institution between March 2016 and September 2017. Indication for the procedure was incomplete emptying, recurrent urinary tract infections, and dysuria. On follow-up, patients were assessed for clinical success by absence of infections, symptoms, and cystoscopic evaluation. Robotic assisted dissection is performed to open the space of Retzius and mobilize the bladder. The cystoscope is passed to the level of the BNC, and Firefly technology is used to localize the BNC. The BNC is incised anteriorly, and a V-shaped bladder flap is advanced into the BNC in a Y-V plasty fashion. We place a perioperative closed suction drain, which is removed before discharge, and a 22 Fr catheter, which that will be removed in the office at approximately 2 weeks. Six men developed recalcitrant BNCs and 1 developed a recalcitrant vesicourethral anastomotic stenosis. All patients had previously undergone an endoscopic procedure. Median time for last attempt at endoscopic management to robot-assisted bladder neck repair was 4.7 months. The average number of prior attempts at endoscopic management was 2. All patients underwent RYVBNR without conversion to open surgery. The median operative time was 240 minutes, estimated blood loss was 67 mL, and length of stay was 1 day. There were no intraoperative complications. Catheters were removed in the office at a median time of 15 days. At a median follow-up of 8 months, all cases were successful with no evidence of recurrence. Only 2 patients had persistent urinary incontinence at 1 pad per day. RYVBNR with a Y-V plasty is a feasible and effective technique for managing a difficult reconstructive problem. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Robotic Thyroidectomy: Comparison of a Postauricular Facelift Approach with a Gasless Unilateral Axillary Approach.

    PubMed

    Sung, Eui Suk; Ji, Yong Bae; Song, Chang Myeon; Yun, Bo Ram; Chung, Won Sang; Tae, Kyung

    2016-06-01

    Robotic thyroidectomy using remote access approaches has gained popularity with patients seeking to avoid neck scarring and enhanced cosmetic satisfaction. The aim of this study was to compare the efficacy and advantages of a postauricular facelift approach vs a gasless unilateral axillary (GUA) approach in robotic thyroidectomy. Case series with chart review. University tertiary care hospital. We retrospectively analyzed the data of 65 patients who underwent robotic thyroidectomy with or without central neck dissection using a GUA approach (45 patients) or a postauricular facelift approach (20 patients) between September 2013 and December 2014. We excluded patients who underwent simultaneous lateral neck dissection or completion thyroidectomy. Robotic procedures were completed without being converted to an open procedure in all patients. There were no significant differences in terms of patient and tumor characteristics, extent of thyroidectomy and central neck dissection, operative time, complications, and postoperative pain between the 2 approaches, except the higher female ratio in the GUA approach group (female ratio, 95.6% vs 75%, P = .042). Cosmetic satisfaction evaluated by a questionnaire was not significantly different between the 2 groups, and most patients of both groups (85.7%) were satisfied with postoperative cosmesis. Both GUA and postauricular facelift approaches are feasible, with no significant adverse events in patients, and result in excellent cosmesis. However, a GUA approach seems to be superior when performing total thyroidectomy using a unilateral incision based on the preliminary result. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  5. Current Status of Robot-Assisted Radical Cystectomy: What is the Real Benefit?

    PubMed

    Takenaka, Atsushi

    2015-09-01

    In recent years, robot-assisted radical cystectomy has received attention worldwide as a useful procedure that helps to overcome the limitations of open radical cystectomy. We compared the surgical technique, perioperative and oncological outcomes, and learning curve of robot-assisted radical cystectomy with those of open radical cystectomy. The indications for robot-assisted radical cystectomy are identical to those of open radical cystectomy. Relative contraindications are due to patient positioning in the Trendelenburg position for long periods. Urinary diversion is performed either extracorporeally with a small skin incision or intracorporeally with a totally robotic-assisted maneuver. Accordingly, robot-assisted radical cystectomy can be performed safely with an acceptable operative time, little blood loss, and low transfusion rates. The lymph node yield and positive surgical margin rate were not significantly different between robot-assisted radical cystectomy and open radical cystectomy. The survival rates after robot-assisted radical cystectomy are estimated to be similar to that after open radical cystectomy. However, the recurrence pattern is different between robot-assisted radical cystectomy and open radical cystectomy, i.e., extrapelvic lymph node recurrence and peritoneal carcinomatosis were more frequently found in patients who underwent robot-assisted radical cystectomy than in those who underwent open radical cystectomy. Further validation is necessary to prove the feasibility of oncological control. A steep learning curve is one of the benefits of the new technique. The experience of only 50 robot-assisted radical prostatectomies is a minimum requirement for performing feasible robot-assisted radical cystectomy, and surgeons who have performed only 30 surgeries can reach an acceptable level of quality for robot-assisted radical cystectomy.

  6. Initial multicentre experience of 68 gallium-PSMA PET/CT guided robot-assisted salvage lymphadenectomy: acceptable safety profile but oncological benefit appears limited.

    PubMed

    Siriwardana, Amila; Thompson, James; van Leeuwen, Pim J; Doig, Shaela; Kalsbeek, Anton; Emmett, Louise; Delprado, Warick; Wong, David; Samaratunga, Hemamali; Haynes, Anne-Maree; Coughlin, Geoff; Stricker, Phillip

    2017-11-01

    To evaluate the safety and short-term oncological outcomes of 68 gallium-labelled prostate-specific membrane antigen ( 68 Ga-PSMA) positron-emission tomography (PET)/computed tomography (CT)-directed robot-assisted salvage node dissection (RASND) for prostate cancer oligometastatic nodal recurrence. Between February 2014 and April 2016, 35 patients across two centres underwent RASND for 68 Ga-PSMA PET/CT-detected oligometastatic nodal recurrence. RASND was performed using targeted pelvic dissection, unilateral extended pelvic template or bilateral extended pelvic template dissection, depending on previous pelvic treatment and extent/location of nodal disease. Complications were reported using the Clavien-Dindo classification system. Definitions of prostate-specific antigen (PSA) treatment response to RASND were defined as 6-week PSA <0.2 ng/mL (broad definition) or PSA <0.05 ng/mL (strict definition) in those who had undergone primary prostatectomy, and 6-week PSA level < post-radiotherapy nadir in those who had undergone primary radiotherapy. Biochemical recurrence (BCR) after RASND was defined as a PSA >0.2 ng/mL or PSA > nadir, for those who had undergone primary prostatectomy and primary radiotherapy, respectively. Predictors of treatment response were analysed using univariate binary logistic regression. A total of 58 lesions suspicious for lymph node metastases (LNM) in 35 patients were detected on 68 Ga-PSMA imaging. A total of 32 patients (91%) had histopathologically proven LNM at RASND, with a total of 87 LNM and a median (interquartile range) of 2 (1-3) LNM per patient. In all, eight patients (23%) experienced complications, all Clavien-Dindo grade ≤2. Treatment response was seen in 15 (43%) and 11 patients (31%), using the broad and strict definitions, respectively. BCR-free survival and clinical recurrence-free survival at a median follow-up of 12 months were 23% and 66%, respectively, for the entire cohort. Bilateral template dissection was the only significant univariate predictor of treatment response in our cohort. Although RASND appears safe and feasible, less than half of our cohort had a treatment response, and less than a quarter experienced BCR-free survival at 12-month median follow-up. 68 Ga-PSMA imaging underestimates micro-metastatic disease, therefore RASND will rarely be curative. Strict patient selection and restricting RASND to clinical trials is recommended. Long-term follow-up from such trials is required to further assess potential quality of life and mortality benefits. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  7. Megasessions for Robotic Hair Restoration.

    PubMed

    Pereira, Joa O Carlos; Pereira Filho, Joa O Carlos; Cabrera Pereira, Joa O Pedro

    2016-11-01

    A robotic system can select and remove individual hair follicles from the donor area with great precision and without fatigue. This report describes the use of the robotic system in a megasession for hair restoration. Patients were instructed to cut their hair to 1.0 to 1.2 mm before surgery. The robot selected and removed 600 to 800 grafts per hour so the follicular units (FU)s could be transplanted manually to recipient sites. The robot arm consists of a sharp inner punch and a blunt outer punch which together separate FUs from the sur- rounding tissue. Stereoscopic cameras controlled by image processing software allow the system to identify the angle and direction of hair growth. The physician and one assistant control the harvesting with a hand-held remote control and computer monitor while the patient is positioned in an adjustable chair. When the robot has harvested all the FUs they are removed by technicians with small forceps. Hairline design, creation of recipient sites, and graft placement are performed manually by the physician. Clinical photographs before and after surgery show that patients experience excellent outcomes with the robotic megasession. Phy- sician fatigue during graft extraction is reduced because the robot performs the repetitive movements without fatigue. Variability of graft extraction is minimized because the robot's optical system can be programmed to choose the best FUs. The transection rate is reduced because the robot's graft extraction system uses two needles, a sharp one to piece the skin and a blunt needle to dissect the root without trauma. A robotic megasession for hair restoration is minimally invasive, does not result in linear scars in the donor area, and is associated with minimal fatigue and discomfort for both patient and physician. Healing is rapid and patients experience a high level of satisfaction with the results. J Drugs Dermatol. 2016;15(11):1407-1412..

  8. The utility of indocyanine green fluorescence imaging during robotic adrenalectomy.

    PubMed

    Colvin, Jennifer; Zaidi, Nisar; Berber, Eren

    2016-08-01

    Indocyanine green (ICG) has been used for medical imaging since 1950s, but has more recently become available for use in minimally invasive surgery owing to improvements in technology. This study investigates the use of ICG florescence to guide an accurate dissection by delineating the borders of adrenal tumors during robotic adrenalectomy (RA). This prospective study compared conventional robotic view with ICG fluorescence imaging in 40 consecutive patients undergoing RA. Independent, non-blinded observers assessed how accurately ICG fluorescence delineated the borders of adrenal tumors compared to conventional robotic view. A total of 40 patients underwent 43 adrenalectomies. ICG imaging was superior, equivalent, or inferior to conventional robotic view in 46.5% (n = 20), 25.6% (n = 11), and 27.9% (n = 12) of the procedures. On univariate analysis, the only parameter that predicted the superiority of ICG imaging over conventional robotic view was the tumor type, with adrenocortical tumors being delineated more accurately on ICG imaging compared to conventional robotic view. This study demonstrates the utility of ICG to guide the dissection and removal of adrenal tumors during RA. A simple reproducible method is reported, with a detailed description of the utility based on tumor type, approach and side. J. Surg. Oncol. 2016;114:153-156. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. [Partial cystectomy for bladder endometriosis: Robotic assisted laparoscopy versus standard laparoscopy].

    PubMed

    le Carpentier, M; Merlot, B; Bot Robin, V; Rubod, C; Collinet, P

    2016-06-01

    To compare robot-assisted laparoscopy (RL) and conventional laparoscopy (CL) in surgery for bladder endometriosis. A retrospective study was conducted between January 2007 and December 2013, including patients with bladder endometriosis receiving at least a partial cystectomy by RL or CL. The primary endpoint was the presence of a radiological recurrence at bladder level. We included 15 patients in the RL group and 22 in the CL group. The median age was 29 years±7 years. The symptoms were similar in the 2 groups. Pre-surgical mapping of the lesions was carried out with MRI. Sixty percent of patients in the RL group vs 91% in the CL group had other associated endometriosis lesions, P=0.04. The median size of the bladder lesion was 30±8mm in the RL group vs 23±7mm in the CL group, P=0.03. The median operative time was 210 vs 225min, P=0.8. We did not find any significant difference in intraoperative and early and late postoperative complications between the 2 groups. The median length of stay was 5 days vs 6 days. The proportion of relapse was 20 vs 23%, P>0.05. Clinical improvement was similar between the groups, i.e. 93 vs 86%, P=0.6 and the pregnancy rate was 93 vs 86%, P=0.6. Robot-assisted laparoscopy in the surgical treatment of bladder endometriosis as compared to traditional laparoscopy does not seem to have an adverse effect neither on the risk of recurrence nor on the occurrence of intra- and postoperative complications. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Da Vinci Xi and Si platforms have equivalent perioperative outcomes during robot-assisted partial nephrectomy: preliminary experience.

    PubMed

    Abdel Raheem, Ali; Sheikh, Abulhasan; Kim, Dae Keun; Alatawi, Atalla; Alabdulaali, Ibrahim; Han, Woong Kyu; Choi, Young Deuk; Rha, Koon Ho

    2017-03-01

    The aims of this study were to compare the perioperative outcomes of da Vinci Xi to Si during robotic-assisted partial nephrectomy (RAPN) and to discuss the feasibility of our novel port placement scheme for the da Vinci Xi platform, to overcome the existing kinetic and technical difficulties we faced with the linear port placement in patients with a small body habitus. A retrospective data analysis of patients who underwent RPN using da Vinci Xi (n = 18) was carried out. The outcomes of the Xi group were compared with the Si group (n = 18) selected using a case-matched methodology. For da Vinci Xi, we applied the universal linear port placement in 12 patients and our modified port placement in the remaining 6 patients. The Xi group had a shorter mean docking time of 17.8 ± 2.6 min compared to the Si group of 20.5 ± 2.1 min (p = 0.002); otherwise, no significant difference was present with regard to the remaining perioperative variables (p > 0.05). The modified Xi port placement had a shorter mean console time of 70.8 ± 9.7 min compared to the universal linear port placement of 89.3 ± 17.2 min (p = 0.03). Moreover, it provided a broader field of vision with excellent robotic arms movement, minimizing collisions and allowing an easier and comfortable surgical assist. Da Vinci Xi appears to be feasible and safe during RPN with similar outcomes to Si. The novel Xi port placement makes surgery easier in patients with low BMI.

  11. Robotic surgery in urologic oncology: gathering the evidence.

    PubMed

    Skolarus, Ted A; Zhang, Yun; Hollenbeck, Brent K

    2010-08-01

    In less than a decade, the widespread application of robotic technology to the field of urologic oncology has permanently altered the way urologists approach malignancy. The short-term benefits of minimally invasive surgery using robotic assistance (i.e., decreased blood loss, improved convalescence and ergonomic appeal), as well as a broad marketing campaign, have helped the technology gain traction in the field of urology. Although the long-term benefits of its use in urologic surgery are less clear and the costs of robotic surgery are consistently greater than those of other approaches, the numbers of prostate, kidney and bladder cancer cases continue to rise. Identifying transferable surgical processes of care that matter most for each of the robotic cases in urologic oncology (e.g., prostatectomy, cystectomy and partial nephrectomy) is a next step toward broadly improving the quality of urologic cancer care. To this end, urologic professional societies and their surgeons should aim to identify underwriters for and participate in large clinical registries and surgical quality collaboratives.

  12. Non-orthogonal tool/flange and robot/world calibration.

    PubMed

    Ernst, Floris; Richter, Lars; Matthäus, Lars; Martens, Volker; Bruder, Ralf; Schlaefer, Alexander; Schweikard, Achim

    2012-12-01

    For many robot-assisted medical applications, it is necessary to accurately compute the relation between the robot's coordinate system and the coordinate system of a localisation or tracking device. Today, this is typically carried out using hand-eye calibration methods like those proposed by Tsai/Lenz or Daniilidis. We present a new method for simultaneous tool/flange and robot/world calibration by estimating a solution to the matrix equation AX = YB. It is computed using a least-squares approach. Because real robots and localisation are all afflicted by errors, our approach allows for non-orthogonal matrices, partially compensating for imperfect calibration of the robot or localisation device. We also introduce a new method where full robot/world and partial tool/flange calibration is possible by using localisation devices providing less than six degrees of freedom (DOFs). The methods are evaluated on simulation data and on real-world measurements from optical and magnetical tracking devices, volumetric ultrasound providing 3-DOF data, and a surface laser scanning device. We compare our methods with two classical approaches: the method by Tsai/Lenz and the method by Daniilidis. In all experiments, the new algorithms outperform the classical methods in terms of translational accuracy by up to 80% and perform similarly in terms of rotational accuracy. Additionally, the methods are shown to be stable: the number of calibration stations used has far less influence on calibration quality than for the classical methods. Our work shows that the new method can be used for estimating the relationship between the robot's and the localisation device's coordinate systems. The new method can also be used for deficient systems providing only 3-DOF data, and it can be employed in real-time scenarios because of its speed. Copyright © 2012 John Wiley & Sons, Ltd.

  13. Performing the Difficult Cholecystectomy Using Combined Endoscopic and Robotic Techniques: How I Do It.

    PubMed

    Magge, Deepa; Steve, Jennifer; Novak, Stephanie; Slivka, Adam; Hogg, Mellissa; Zureikat, Amer; Zeh, Herbert J

    2017-03-01

    Laparoscopic cholecystectomy is the standard of care for cholelithiasis as well as cholecystitis. However, in the setting of Mirizzi syndrome or gangrenous cholecystitis where the critical view cannot be ascertained, subtotal cholecystectomy may be necessary. Using the robot-assisted approach, difficult cholecystectomies can be performed upfront without need for partial cholecystectomy. Even in the setting of Mirizzi syndrome where severe scarring and fibrosis are evident, definitive cholecystectomy and takedown of the cholechystocholedochal fistula can be performed in a safe and feasible fashion following successful endoscopic common bile duct stent placement. The purposes of this report are to review the history of Mirizzi syndrome as well as its traditional and novel treatment techniques and highlight technical pearls of the robotic approach to this diagnosis.

  14. OLDER ADULTS’ PREFERENCES FOR AND ACCEPTANCE OF ROBOT ASSISTANCE FOR EVERYDAY LIVING TASKS

    PubMed Central

    Smarr, Cory-Ann; Prakash, Akanksha; Beer, Jenay M.; Mitzner, Tracy L.; Kemp, Charles C.; Rogers, Wendy A.

    2014-01-01

    Many older adults value their independence and prefer to age in place. Robots can be designed to assist older people with performing everyday living tasks and maintaining their independence at home. Yet, there is a scarcity of knowledge regarding older adults’ attitudes toward robots and their preferences for robot assistance. Twenty-one older adults (M = 80.25 years old, SD = 7.19) completed questionnaires and participated in structured group interviews investigating their openness to and preferences for assistance from a mobile manipulator robot. Although the older adults were generally open to robot assistance for performing home-based tasks, they were selective in their views. Older adults preferred robot assistance over human assistance for many instrumental (e.g., housekeeping, laundry, medication reminders) and enhanced activities of daily living (e.g., new learning, hobbies). However, older adults were less open to robot assistance for some activities of daily living (e.g., shaving, hair care). Results from this study provide insight into older adults’ attitudes toward robot assistance with home-based everyday living tasks. PMID:25284971

  15. Domestic Robots for Older Adults: Attitudes, Preferences, and Potential

    PubMed Central

    Mitzner, Tracy L.; Beer, Jenay M.; Prakash, Akanksha; Chen, Tiffany L.; Kemp, Charles C.; Rogers, Wendy A.

    2014-01-01

    The population of older adults in America is expected to reach an unprecedented level in the near future. Some of them have difficulties with performing daily tasks and caregivers may not be able to match pace with the increasing need for assistance. Robots, especially mobile manipulators, have the potential for assisting older adults with daily tasks enabling them to live independently in their homes. However, little is known about their views of robot assistance in the home. Twenty-one independently living older Americans (65–93 years old) were asked about their preferences for and attitudes toward robot assistance via a structured group interview and questionnaires. In the group interview, they generated a diverse set of 121 tasks they would want a robot to assist them with in their homes. These data, along with their questionnaire responses, suggest that the older adults were generally open to robot assistance but were discriminating in their acceptance of assistance for different tasks. They preferred robot assistance over human assistance for tasks related to chores, manipulating objects, and information management. In contrast, they preferred human assistance to robot assistance for tasks related to personal care and leisure activities. Our study provides insights into older adults' attitudes and preferences for robot assistance with everyday living tasks in the home which may inform the design of robots that will be more likely accepted by older adults. PMID:25152779

  16. Domestic Robots for Older Adults: Attitudes, Preferences, and Potential.

    PubMed

    Smarr, Cory-Ann; Mitzner, Tracy L; Beer, Jenay M; Prakash, Akanksha; Chen, Tiffany L; Kemp, Charles C; Rogers, Wendy A

    2014-04-01

    The population of older adults in America is expected to reach an unprecedented level in the near future. Some of them have difficulties with performing daily tasks and caregivers may not be able to match pace with the increasing need for assistance. Robots, especially mobile manipulators, have the potential for assisting older adults with daily tasks enabling them to live independently in their homes. However, little is known about their views of robot assistance in the home. Twenty-one independently living older Americans (65-93 years old) were asked about their preferences for and attitudes toward robot assistance via a structured group interview and questionnaires. In the group interview, they generated a diverse set of 121 tasks they would want a robot to assist them with in their homes. These data, along with their questionnaire responses, suggest that the older adults were generally open to robot assistance but were discriminating in their acceptance of assistance for different tasks. They preferred robot assistance over human assistance for tasks related to chores, manipulating objects, and information management. In contrast, they preferred human assistance to robot assistance for tasks related to personal care and leisure activities. Our study provides insights into older adults' attitudes and preferences for robot assistance with everyday living tasks in the home which may inform the design of robots that will be more likely accepted by older adults.

  17. The role of telementoring and telerobotic assistance in the provision of laparoscopic colorectal surgery in rural areas.

    PubMed

    Sebajang, H; Trudeau, P; Dougall, A; Hegge, S; McKinley, C; Anvari, M

    2006-09-01

    The aim of this study was to assess whether telementoring and telerobotic assistance would improve the range and quality of laparoscopic colorectal surgery being performed by community surgeons. We present a series of 18 patients who underwent telementored or telerobotically assisted laparoscopic colorectal surgery in two community hospitals between December 2002 and December 2003. Four community surgeons with no formal advanced laparoscopic fellowship were remotely mentored and assisted by an expert surgeon from a tertiary care center. Telementoring was achieved with real-time two-way audio-video communications over bandwidths of 384 kbps-1.2 mbps and included one redo ileocolic resection, two right hemicolectomies, two sigmoid resections, three low anterior resections, one subtotal colectomy, one reversal of a Hartmann operation, and one abdominoperineal resection. A Zeus TS microjoint system (Computer Motion Inc, Santa Barbara CA) was used to provide telepresence for the telerobotically assisted laparoscopic procedures, which included three right hemicolectomies, three sigmoid resections, and one low anterior resection. There were no major intraoperative complications. There were two minor intraoperative complications involving serosal tears of the colon from the robotic graspers. In the telementored cases, there were two postoperative complications requiring reoperation (intra-abdominal bleeding and small bowel obstruction). Two telementored procedures were converted because of the mentee's inability to find the appropriate planes of dissection. One telerobotically assisted procedure was completed laparoscopically by the local surgeon with aid of telementoring because of inadequate robotic arm position. The median length of hospital stay for this series was 4 days. The surgeons considered telementoring useful in all cases (median score 4 out of 5). The use of remote telerobotic assistance was also considered a significant enabling tool. Telementoring and remote telerobotic assistance are excellent tools for supporting community surgeons and providing patients better access to advanced surgical care.

  18. Promoting Interactions Between Humans and Robots Using Robotic Emotional Behavior.

    PubMed

    Ficocelli, Maurizio; Terao, Junichi; Nejat, Goldie

    2016-12-01

    The objective of a socially assistive robot is to create a close and effective interaction with a human user for the purpose of giving assistance. In particular, the social interaction, guidance, and support that a socially assistive robot can provide a person can be very beneficial to patient-centered care. However, there are a number of research issues that need to be addressed in order to design such robots. This paper focuses on developing effective emotion-based assistive behavior for a socially assistive robot intended for natural human-robot interaction (HRI) scenarios with explicit social and assistive task functionalities. In particular, in this paper, a unique emotional behavior module is presented and implemented in a learning-based control architecture for assistive HRI. The module is utilized to determine the appropriate emotions of the robot to display, as motivated by the well-being of the person, during assistive task-driven interactions in order to elicit suitable actions from users to accomplish a given person-centered assistive task. A novel online updating technique is used in order to allow the emotional model to adapt to new people and scenarios. Experiments presented show the effectiveness of utilizing robotic emotional assistive behavior during HRI scenarios.

  19. The role of assistive robotics in the lives of persons with disability.

    PubMed

    Brose, Steven W; Weber, Douglas J; Salatin, Ben A; Grindle, Garret G; Wang, Hongwu; Vazquez, Juan J; Cooper, Rory A

    2010-06-01

    Robotic assistive devices are used increasingly to improve the independence and quality of life of persons with disabilities. Devices as varied as robotic feeders, smart-powered wheelchairs, independent mobile robots, and socially assistive robots are becoming more clinically relevant. There is a growing importance for the rehabilitation professional to be aware of available systems and ongoing research efforts. The aim of this article is to describe the advances in assistive robotics that are relevant to professionals serving persons with disabilities. This review breaks down relevant advances into categories of Assistive Robotic Systems, User Interfaces and Control Systems, Sensory and Feedback Systems, and User Perspectives. An understanding of the direction that assistive robotics is taking is important for the clinician and researcher alike; this review is intended to address this need.

  20. Robotic-Assisted Versus Laparoscopic Colectomy: Cost and Clinical Outcomes

    PubMed Central

    Davis, Bradley R.; Yoo, Andrew C.; Moore, Matt

    2014-01-01

    Background and Objectives: Laparoscopic colectomies, with and without robotic assistance, are performed to treat both benign and malignant colonic disease. This study compared clinical and economic outcomes for laparoscopic colectomy procedures with and without robotic assistance. Methods: Patients aged ≥18 years having primary inpatient laparoscopic colectomy procedures (cecectomy, right hemicolectomy, left hemicolectomy, and sigmoidectomy) identified by International Classification of Diseases, Ninth Edition procedure codes performed between 2009 and the second quarter of 2011 from the Premier Hospital Database were studied. Patients were matched to a control cohort using propensity scores for disease, comorbidities, and hospital characteristics and were matched 1:1 for specific colectomy procedure. The outcomes of interest were hospital cost of laparoscopic robotic-assisted colectomy compared with traditional laparoscopic colectomy, surgery time, adverse events, and length of stay. Results: Of 25 758 laparoscopic colectomies identified, 98% were performed without robotic assistance and 2% were performed with robotic assistance. After matching, 1066 patients remained, 533 in each group. Lengths of stay were not significantly different between the matched cohorts, nor were rates of major, minor, and/or surgical complications. Inpatient procedures with robotic assistance were significantly more costly than those without robotic assistance ($17 445 vs $15 448, P = .001). Operative times were significantly longer for robotic-assisted procedures (4.37 hours vs 3.34 hours, P < .001). Conclusion: Segmental colectomies can be performed safely by either laparoscopic or robotic-assisted methods. Increased per-case hospital costs for robotic-assisted procedures and prolonged operative times suggest that further investigation is warranted when considering robotic technology for routine laparoscopic colectomies. PMID:24960484

  1. Robotic-assisted versus laparoscopic colectomy: cost and clinical outcomes.

    PubMed

    Davis, Bradley R; Yoo, Andrew C; Moore, Matt; Gunnarsson, Candace

    2014-01-01

    Laparoscopic colectomies, with and without robotic assistance, are performed to treat both benign and malignant colonic disease. This study compared clinical and economic outcomes for laparoscopic colectomy procedures with and without robotic assistance. Patients aged ≥18 years having primary inpatient laparoscopic colectomy procedures (cecectomy, right hemicolectomy, left hemicolectomy, and sigmoidectomy) identified by International Classification of Diseases, Ninth Edition procedure codes performed between 2009 and the second quarter of 2011 from the Premier Hospital Database were studied. Patients were matched to a control cohort using propensity scores for disease, comorbidities, and hospital characteristics and were matched 1:1 for specific colectomy procedure. The outcomes of interest were hospital cost of laparoscopic robotic-assisted colectomy compared with traditional laparoscopic colectomy, surgery time, adverse events, and length of stay. Of 25,758 laparoscopic colectomies identified, 98% were performed without robotic assistance and 2% were performed with robotic assistance. After matching, 1066 patients remained, 533 in each group. Lengths of stay were not significantly different between the matched cohorts, nor were rates of major, minor, and/or surgical complications. Inpatient procedures with robotic assistance were significantly more costly than those without robotic assistance ($17,445 vs $15,448, P = .001). Operative times were significantly longer for robotic-assisted procedures (4.37 hours vs 3.34 hours, P < .001). Segmental colectomies can be performed safely by either laparoscopic or robotic-assisted methods. Increased per-case hospital costs for robotic-assisted procedures and prolonged operative times suggest that further investigation is warranted when considering robotic technology for routine laparoscopic colectomies.

  2. Application of a disturbance-rejection controller for robotic-enhanced limb rehabilitation trainings.

    PubMed

    Madoński, R; Kordasz, M; Sauer, P

    2014-07-01

    The paper presents an application of a special case of an Active Disturbance Rejection Controller (ADRC) in governing a proper realization of basic limb rehabilitation trainings. The experimental study is performed on a model of a flexible joint manipulator, whose behavior resembles a real robotic rehabilitation device. The multidimensional character of the considered assisting mechanism makes it a nontrivial modeling and control problem. However, by the use of the ADRC approach, the modeling uncertainty in the plant is partially decoupled from the system, which increases the robustness of the whole control framework against both internal and external disturbances. © 2013 ISA. Published by ISA. All rights reserved.

  3. Da Vinci robot-assisted system for thymectomy: experience of 55 patients in China.

    PubMed

    Jun, Yi; Hao, Li; Demin, Li; Guohua, Dong; Hua, Jing; Yi, Shen

    2014-09-01

    Da Vinci robot-assisted thymectomy has been used in the past several years in China, however, practical experience in performing this approach in China remains limited. Thus, the study aimed to evaluate the experience of da Vinci robot-assisted thymectomy in China. From June 2010 to December 2012, 55 patients with diseases of the thymus underwent thymectomy using the da Vinci surgical HD robotic system. The clinical data of the da Vinci robot-assisted thymectomies were compared with the data of video-assisted thoracoscopic thymectomies in the same period. All da Vinci robot operations were successful. This is a retrospective analysis which demonstrated that compared with video-assisted thoracoscopic thymectomy in the same period, the clinical outcomes of da Vinci robot-assisted thymectomy were not significantly different. The da Vinci robot-assisted thymectomy is a safe, minimally invasive, and convenient operation, and shows promise for general thoracic surgery in China. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Toward robot-assisted neurosurgical lasers.

    PubMed

    Motkoski, Jason W; Yang, Fang Wei; Lwu, Shelly H H; Sutherland, Garnette R

    2013-04-01

    Despite the potential increase in precision and accuracy, laser technology is not widely used in neurological surgery. This in part relates to challenges associated with the early introduction of lasers into neurosurgery. Considerable advances in laser technology have occurred, which together with robotic technology could create an ideal platform for neurosurgical application. In this study, a 980-nm contact diode laser was integrated with neuroArm. Preclinical evaluation involved partial hepatectomy, bilateral nephrectomy, splenectomy, and bilateral submandibular gland excision in a Sprague-Dawley rat model (n = 50). Total surgical time, blood loss as weight of surgical gauze before and after the procedure, and the incidence of thermal, vascular, or lethal injury were recorded and converted to an overall performance score. Thermal damage was evaluated in the liver using tissue samples stained with hematoxylin and eosin. Clinical studies involved step-wise integration of the 980-nm laser system into four neurosurgical cases. Results demonstrate the successful integration of contact laser technology into microsurgery, with and without robotic assistance. In preclinical studies, the laser improved microsurgical performance and reduced thermal damage, while neuroArm decreased intra- and intersurgeon variability. Clinical studies demonstrate dutility in meningioma resection (n = 4). Together, laser and robotic technology offered a more consistent, expedient, and precise tool for microsurgery.

  5. Robotic treatment of a type 2 calyceal diverticulum in a child: is suture closure and marsupialisation enough for a good outcome?

    PubMed

    Sripathi, V; Mitra, Aparajita; Padankatti, Rajiv L; Ganesan, T

    2017-10-27

    Calyceal diverticula in children are rare and 20% eventually become symptomatic. Following the use of laparoscopic or endoscopic treatments, 85% of children report symptomatic relief. However, complete radiological resolution is seen only in three-fourths of the laparoscopic group and a quarter of those treated via endoscopy. Diathermy ablation of the lining and/or prolonged double J stenting has not altered this outcome. The robotic approach is superior to the other two techniques as the leak can be clearly identified and securely suture ligated. We believe that this is the third published report of the successful closure of a calyceal diverticulum in a child using robotic assistance. A ten-year-old boy presented with severe pain in the right flank and a palpable renal swelling. Retrograde injection of contrast outlined a large exophytic calyceal diverticulum (type 2) in the lower pole. Robotic assistance allowed precise suture closure of the neck as well as partial marsupialisation of the diverticulum. The child was discharged within 48 h and remains symptom free 18 months later. Calyceal diverticula are rare but technically challenging entities. We have shown a good outcome with only suture closure of the leak. Diathermy ablation of the lining and prolonged internal stenting were avoided.

  6. Towards Development of Robotic Aid for Rehabilitation of Locomotion-Impaired Subjects

    NASA Technical Reports Server (NTRS)

    Bejczy, Antal K.

    2000-01-01

    Manual assistance of therapists to help movement of legs of spinal cord injured (SCI) subjects during stepping on a treadmill for locomotion rehabilitation has severe economic and technical limitations. Scientists at the Department of Physiological Science at the University of California Los Angeles (UCLA) and roboticists at the Jet Propulsion Laboratory (JPL) initiated a joint effort to develop a robotic mechanism capable of performing controlled motions equivalent to the arm and hand motions of therapists assisting the stepping of locomotion impaired subjects on a treadmill, while the subjects' body weight is partially supported by an overhead harness. A first necessary technical step towards this development is to measure and understand the kinematics and dynamics of the therapists' arm and hand motions as they are reflected on the subjects' leg movement. This paper describes an initial measurement system developed for this purpose together with the related measurement results, and outlines the planned future technical work.

  7. Occult Radiographically Evident Port-Site Hernia After Robot-Assisted Urologic Surgery: Incidence and Risk Factors.

    PubMed

    Christie, Matthew C; Manger, Jules P; Khiyami, Abdulaziz M; Ornan, Afshan A; Wheeler, Karen M; Schenkman, Noah S

    2016-01-01

    Laparoscopic trocar-site hernias (TSH) are rare, with a reported incidence of 1% or less. The incidence of occult radiographically evident hernias has not been described after robot-assisted urologic surgery. We evaluated the incidence and risk factors of this problem. A single-institution retrospective review of robot-assisted urologic surgery was performed from April 2009 to December 2012. Patients with preoperative and postoperative CT were included for analysis. Imaging was reviewed by two radiologists and one urologist. One hundred four cases were identified, including 60 partial nephrectomy, 38 prostatectomy, and 6 cystectomy. Mean age was 58 years and mean body mass index (BMI) was 29 kg/m(2). The cohort was 77% male. Ten total hernias were identified by CT in 8 patients, 2 of which were clinically evident hernias. Excluding these two hernias, occult port-site hernias were identified radiographically in seven patients. Per-patient incidence of occult TSH was 6.7% (7/104), and per-port incidence was 1.4% (8/564). All hernias were midline and 30% contained bowel. Eight of the 10 occurred at 12 mm sites (p = 0.0065) and 3 of the 10 occurred at extended incisions. Age, gender, BMI, smoking status, diabetes mellitus, immunosuppressive drug therapy, ASA score, procedure, blood loss, prior abdominal surgery, and history of hernia were not significant risk factors. Specimen size >40 g (p = 0.024) and wound infection (p = 0.0052) were significant risk factors. While the incidence of clinically evident port-site hernia remains low in robot-assisted urologic surgery, the incidence of CT-detected occult hernia was 6.7% in this series. These occurred most often in sites extended for specimen extraction and at larger port sites. This suggests more attention should be paid to fascial closure at these sites.

  8. Performance Evaluation Methods for Assistive Robotic Technology

    NASA Astrophysics Data System (ADS)

    Tsui, Katherine M.; Feil-Seifer, David J.; Matarić, Maja J.; Yanco, Holly A.

    Robots have been developed for several assistive technology domains, including intervention for Autism Spectrum Disorders, eldercare, and post-stroke rehabilitation. Assistive robots have also been used to promote independent living through the use of devices such as intelligent wheelchairs, assistive robotic arms, and external limb prostheses. Work in the broad field of assistive robotic technology can be divided into two major research phases: technology development, in which new devices, software, and interfaces are created; and clinical, in which assistive technology is applied to a given end-user population. Moving from technology development towards clinical applications is a significant challenge. Developing performance metrics for assistive robots poses a related set of challenges. In this paper, we survey several areas of assistive robotic technology in order to derive and demonstrate domain-specific means for evaluating the performance of such systems. We also present two case studies of applied performance measures and a discussion regarding the ubiquity of functional performance measures across the sampled domains. Finally, we present guidelines for incorporating human performance metrics into end-user evaluations of assistive robotic technologies.

  9. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    PubMed

    Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain

    2015-01-01

    In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  10. Endolymphatic Ethiodized Oil Intranodal Lymphangiography and Cyanoacrylate Glue Embolization for the Treatment of Postoperative Lymphatic Leak After Robot-Assisted Laparoscopic Pelvic Resection.

    PubMed

    Hill, Hannah; Srinivasa, Ravi N; Gemmete, Joseph J; Hage, Anthony; Bundy, Jacob; Chick, Jeffrey Forris Beecham

    2018-01-01

    Purpose: To report the approach, technical success, clinical outcomes, complications, and follow-up of ethiodized oil intranodal lymphangiography with cyanoacrylate glue embolization for the treatment of lymphatic leak after robot-assisted laparoscopic pelvic resection. Materials and Methods: Four men with mean age 68.7 ± 14.3 years were treated with ethiodized oil intranodal lymphangiography with cyanoacrylate embolization for postoperative lymphatic leak. Patients underwent either (1) cystoprostatectomy with ileal conduit and bilateral extensive pelvic lymph node dissection for muscle-invasive urothelial carcinoma and presented with postoperative lymphatic ascites ( n  = 2) or (2) prostatectomy with bilateral standard pelvic lymph node dissection for prostate carcinoma and presented with postoperative pelvic lymphoceles ( n  = 2). Intranodal lymphangiography and embolization procedural details, technical success, clinical outcomes, and follow-up were recorded. Results: In four patients, a total of six ethiodized oil intranodal lymphangiograms were performed, two procedures being repeated interventions. Inguinal lymph node catheterization and ethiodized oil lymphangiography was technically effective in all procedures. A mean of 5.2 ± 2.0 mL of ethiodized oil was used for lymphatic opacification. Cyanoacrylate was diluted to 24.2% with ethiodized oil and 0.44 mL of cyanoacrylate was instilled during first time interventions. On repeat procedures, cyanoacrylate was diluted to 51.7%, and 0.52 mL was instilled. The primary clinical success rate was 50% ( n  = 2/4). Clinical success was achieved in all patients after two interventions ( n  = 4; 100%). No complications were reported at mean follow-up of 134.7 ± 79.2 days (range: 59-248 days). Conclusion: Ethiodized oil intranodal lymphangiography with direct cyanoacrylate glue embolization is a minimally invasive treatment option for lymphatic leak after pelvic resection.

  11. Hybrid laparoscopic and robotic ultrasound-guided radiofrequency ablation-assisted clampless partial nephrectomy.

    PubMed

    Nadler, Robert B; Perry, Kent T; Smith, Norm D

    2009-07-01

    To describe a clampless approach made possible by creating an avascular plane of tissue with radiofrequency ablation. Laparoscopic partial nephrectomy is slowly gaining acceptance as a method to treat small (<4 cm) and select moderate (<7 cm) renal masses. The intricacies of laparoscopic suturing, which result in prolonged warm ischemia times, have delayed the widespread acceptance of this technique among urologists. Laparoscopic suturing to close the collecting system was done using the da Vinci robot. An avascular plane of tissue from coagulation necrosis was achieved with the Habib 4X radiofrequency ablation device and the Rita 1500X generator. Typically, we used a power setting of 50 W but have found settings as low as 25 W necessary to provide hemostasis for larger vessels. The tumor was then sharply excised with a negative margin using robotic scissors and electrocautery to facilitate tissue cutting. Retrograde injection of methylthioninium chloride and saline through an externalized ureteral catheter allowed for precise sutured closure of the collecting system. FloSeal and BioGlue were then applied, making surgical bolsters or parenchymal sutures unnecessary. Intraoperative histologic evaluation of the surgical margin and repeat resection of the tumor bed was possible because the renal hilum was not clamped, and no warm ischemia was used. This technique, which combines the improving technologies of robotic surgery, intraoperative laparoscopic ultrasonography, and radiofrequency ablation, might make more surgeons comfortable with the intricacies of laparoscopic suturing and eliminate prolonged warm ischemia times. Overall, this method should result in more patients being able to undergo minimally invasive laparoscopic partial nephrectomy.

  12. Wrist Rehabilitation Assisted by an Electromyography-Driven Neuromuscular Electrical Stimulation Robot After Stroke.

    PubMed

    Hu, Xiao-Ling; Tong, Raymond Kai-yu; Ho, Newmen S K; Xue, Jing-jing; Rong, Wei; Li, Leonard S W

    2015-09-01

    Augmented physical training with assistance from robot and neuromuscular electrical stimulation (NMES) may introduce intensive motor improvement in chronic stroke. To compare the rehabilitation effectiveness achieved by NMES robot-assisted wrist training and that by robot-assisted training. This study was a single-blinded randomized controlled trial with a 3-month follow-up. Twenty-six hemiplegic subjects with chronic stroke were randomly assigned to receive 20-session wrist training with an electromyography (EMG)-driven NMES robot (NMES robot group, n = 11) and with an EMG-driven robot (robot group, n = 15), completed within 7 consecutive weeks. Clinical scores, Fugl-Meyer Assessment (FMA), Modified Ashworth Score (MAS), and Action Research Arm Test (ARAT) were used to evaluate the training effects before and after the training, as well as 3 months later. An EMG parameter, muscle co-contraction index, was also applied to investigate the session-by-session variation in muscular coordination patterns during the training. The improvement in FMA (shoulder/elbow, wrist/hand) obtained in the NMES robot group was more significant than the robot group (P < .05). Significant improvement in ARAT was achieved in the NMES robot group (P < .05) but absent in the robot group. NMES robot-assisted training showed better performance in releasing muscle co-contraction than the robot-assisted across the training sessions (P < .05). The NMES robot-assisted wrist training was more effective than the pure robot. The additional NMES application in the treatment could bring more improvements in the distal motor functions and faster rehabilitation progress. © The Author(s) 2014.

  13. Assistant Personal Robot (APR): Conception and Application of a Tele-Operated Assisted Living Robot.

    PubMed

    Clotet, Eduard; Martínez, Dani; Moreno, Javier; Tresanchez, Marcel; Palacín, Jordi

    2016-04-28

    This paper presents the technical description, mechanical design, electronic components, software implementation and possible applications of a tele-operated mobile robot designed as an assisted living tool. This robotic concept has been named Assistant Personal Robot (or APR for short) and has been designed as a remotely telecontrolled robotic platform built to provide social and assistive services to elderly people and those with impaired mobility. The APR features a fast high-mobility motion system adapted for tele-operation in plain indoor areas, which incorporates a high-priority collision avoidance procedure. This paper presents the mechanical architecture, electrical fundaments and software implementation required in order to develop the main functionalities of an assistive robot. The APR uses a tablet in order to implement the basic peer-to-peer videoconference and tele-operation control combined with a tactile graphic user interface. The paper also presents the development of some applications proposed in the framework of an assisted living robot.

  14. Robotic Laparoendoscopic Single-site Retroperitioneal Renal Surgery: Initial Investigation of a Purpose-built Single-port Surgical System.

    PubMed

    Maurice, Matthew J; Ramirez, Daniel; Kaouk, Jihad H

    2017-04-01

    Robotic single-site retroperitoneal renal surgery has the potential to minimize the morbidity of standard transperitoneal and multiport approaches. Traditionally, technological limitations of non-purpose-built robotic platforms have hindered the application of this approach. To assess the feasibility of retroperitoneal renal surgery using a new purpose-built robotic single-port surgical system. This was a preclinical study using three male cadavers to assess the feasibility of the da Vinci SP1098 surgical system for robotic laparoendoscopic single-site (R-LESS) retroperitoneal renal surgery. We used the SP1098 to perform retroperitoneal R-LESS radical nephrectomy (n=1) and bilateral partial nephrectomy (n=4) on the anterior and posterior surfaces of the kidney. Improvements unique to this system include enhanced optics and intelligent instrument arm control. Access was obtained 2cm anterior and inferior to the tip of the 12th rib using a novel 2.5-cm robotic single-port system that accommodates three double-jointed articulating robotic instruments, an articulating camera, and an assistant port. The primary outcome was the technical feasibility of the procedures, as measured by the need for conversion to standard techniques, intraoperative complications, and operative times. All cases were completed without the need for conversion. There were no intraoperative complications. The operative time was 100min for radical nephrectomy, and the mean operative time was 91.8±18.5min for partial nephrectomy. Limitations include the preclinical model, the small sample size, and the lack of a control group. Single-site retroperitoneal renal surgery is feasible using the latest-generation SP1098 robotic platform. While the potential of the SP1098 appears promising, further study is needed for clinical evaluation of this investigational technology. In an experimental model, we used a new robotic system to successfully perform major surgery on the kidney through a single small incision without entering the abdomen. Copyright © 2016. Published by Elsevier B.V.

  15. ChiloKey, an interactive identification tool for the geophilomorph centipedes of Europe (Chilopoda, Geophilomorpha).

    PubMed

    Bonato, Lucio; Minelli, Alessandro; Lopresti, Massimo; Cerretti, Pierfilippo

    2014-01-01

    ChiloKey is a matrix-based, interactive key to all 179 species of Geophilomorpha (Chilopoda) recorded from Europe, including species of uncertain identity and those whose morphology is known partially only. The key is intended to assist in identification of subadult and adult specimens, by means of microscopy and simple dissection techniques whenever necessary. The key is freely available through the web at: http://www.biologia.unipd.it/chilokey/ and at http://www.interactive-keys.eu/chilokey/.

  16. Validation of the da Vinci Surgical Skill Simulator across three surgical disciplines: A pilot study

    PubMed Central

    Alzahrani, Tarek; Haddad, Richard; Alkhayal, Abdullah; Delisle, Josée; Drudi, Laura; Gotlieb, Walter; Fraser, Shannon; Bergman, Simon; Bladou, Frank; Andonian, Sero; Anidjar, Maurice

    2013-01-01

    Objective: In this paper, we evaluate face, content and construct validity of the da Vinci Surgical Skills Simulator (dVSSS) across 3 surgical disciplines. Methods: In total, 48 participants from urology, gynecology and general surgery participated in the study as novices (0 robotic cases performed), intermediates (1–74) or experts (≥75). Each participant completed 9 tasks (Peg board level 2, match board level 2, needle targeting, ring and rail level 2, dots and needles level 1, suture sponge level 2, energy dissection level 1, ring walk level 3 and tubes). The Mimic Technologies software scored each task from 0 (worst) to 100 (best) using several predetermined metrics. Face and content validity were evaluated by a questionnaire administered after task completion. Wilcoxon test was used to perform pair wise comparisons. Results: The expert group comprised of 6 attending surgeons. The intermediate group included 4 attending surgeons, 3 fellows and 5 residents. The novices included 1 attending surgeon, 1 fellow, 13 residents, 13 medical students and 2 research assistants. The median number of robotic cases performed by experts and intermediates were 250 and 9, respectively. The median overall realistic score (face validity) was 8/10. Experts rated the usefulness of the simulator as a training tool for residents (content validity) as 8.5/10. For construct validity, experts outperformed novices in all 9 tasks (p < 0.05). Intermediates outperformed novices in 7 of 9 tasks (p < 0.05); there were no significant differences in the energy dissection and ring walk tasks. Finally, experts scored significantly better than intermediates in only 3 of 9 tasks (matchboard, dots and needles and energy dissection) (p < 0.05). Conclusions: This study confirms the face, content and construct validities of the dVSSS across urology, gynecology and general surgery. Larger sample size and more complex tasks are needed to further differentiate intermediates from experts. PMID:23914275

  17. Robotic liver surgery: technical aspects and review of the literature

    PubMed Central

    Bianco, Francesco Maria; Daskalaki, Despoina; Gonzalez-Ciccarelli, Luis Fernando; Kim, Jihun; Benedetti, Enrico

    2016-01-01

    Minimally invasive surgery for liver resections has a defined role and represents an accepted alternative to open techniques for selected cases. Robotic technology can overcome some of the disadvantages of the laparoscopic technique, mainly in the most complex cases. Precise dissection and microsuturing is possible, even in narrow operative fields, allowing for a better dissection of the hepatic hilum, fine lymphadenectomy, and biliary reconstruction even with small bile ducts and easier bleeding control. This technique has the potential to allow for a greater number of major resections and difficult segmentectomies to be performed in a minimally invasive fashion. The implementation of near-infrared fluorescence with indocyanine green (ICG) also allows for a more accurate recognition of vascular and biliary anatomy. The perspectives of this kind of virtually implemented imaging are very promising and may be reflected in better outcomes. The overall data present in current literature suggests that robotic liver resections are at least comparable to both open and laparoscopic surgery in terms of perioperative and postoperative outcomes. This article provides technical details of robotic liver resections and a review of the current literature. PMID:27500143

  18. Assessing the safety and efficacy of full robotic gastrectomy with intracorporeal robot-sewn anastomosis for gastric cancer: A randomized clinical trial.

    PubMed

    Wang, Gang; Jiang, Zhiwei; Zhao, Jian; Liu, Jiang; Zhang, Shu; Zhao, Kun; Feng, Xiaobo; Li, Jieshou

    2016-03-01

    Robotic gastrectomy is increasingly used in gastric cancer patients. This study assessed the safety and efficacy of full robotic gastrectomy with intracorporeal robot-sewn anastomosis for gastric cancer. Three hundred and eleven patients were randomized into an open gastrectomy group or a robotic gastrectomy group, and digestive restorations were performed under direct vision and with intracorporeal robot-sewn anastomosis, respectively. Length of postoperative hospital stay, number of lymph node dissections, surgical duration, blood loss, and complication rate after surgery were recorded. There were no significant differences in the number of lymph node dissections (30.9 ± 10.4 vs. 29.3 ± 9.7 days, P = 0.281) or complication rates (10.3 vs. 9.3%, P = 0.756) between the two groups. Surgical duration was significantly longer in the robotic gastrectomy group than in the open gastrectomy group (242.7 ± 43.8 vs. 192.4 ± 31.5 min, P = 0.002), whereas blood loss was less (94.2 ± 51.5 vs. 152.8 ± 76.9 ml, P < 0.001), length of postoperative hospital stay was shorter (5.6 ± 1.9 vs. 6.7 ± 1.9 days, P = 0.021), and postoperative restoration of bowel function was earlier (2.6 ± 1.1 vs. 3.1 ± 1.2 days, P = 0.028). Full robotic gastrectomy with intracorporeal robot-sewn anastomosis for gastric cancer is safe and does not increase the complication risk during or after surgery. J. Surg. Oncol. 2016;113:397-404. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Health resource utilization and costs during the first 90 days following robot-assisted hysterectomy.

    PubMed

    Dandolu, Vani; Pathak, Prathamesh

    2018-06-01

    To compare health resource utilization, costs and readmission rates between robot-assisted and non-robot-assisted hysterectomy during the 90 days following surgery. The study used 2008-2012 Truven Health MarketScan data. All patients admitted as inpatients with a CPT code for hysterectomy between January 2008 and September 2012 were identified and the first hysterectomy-related admission in each patient was included. Patients were categorized based on the route of their hysterectomy and the use of laparoscopy as: total abdominal hysterectomy, vaginal hysterectomy (VH), laparoscopy-assisted supracervical hysterectomy, laparoscopy-assisted vaginal hysterectomy' and total laparoscopic hysterectomy (TLH). Hospitalization costs, including hospital, physician, pharmacy and facility costs, were calculated for the index admissions and for the 90-day follow-up periods. Health resource utilization was determined in terms of inpatient readmissions, outpatient visits, and emergency room visits, RESULTS: There were 302,923 hysterectomies performed over 5 years for benign indications in the inpatient setting (55% abdominal, 17% vaginal, and 28% laparoscopic). Concurrent use of robot assistance steadily increased and was reported in 50% of TLH procedures in 2012. The rates of readmission overall were 4.9% for robot-assisted procedures and 4.3% for procedures without robot assistance (OR 0.89, CI 0.82-0.97). Readmission rates were lowest for VH (3.2%) and highest for TLH (5.6%). Following robot-assisted hysterectomy and VH, 8.3% and 4.6% of patients, respectively, had more than ten outpatient visits in the 90-day follow-up period. The average total cost for 90 days was $16,820 for robot-assisted hysterectomy and $13,031 for procedures without robot assistance. Of the additional costs for robot-assisted surgery, 25% were incurred in the 90-day follow-up period. The study using private insurance data found that robot-assisted hysterectomy was associated with higher health resource utilization and costs than other minimally invasive approaches. Given the high costs associated with robot-assisted hysterectomy, it is important to understand the specific indications for this approach and to identify the patients who may benefit.

  20. Robot-assisted general surgery.

    PubMed

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  1. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    PubMed Central

    Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain

    2015-01-01

    In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning. PMID:26485148

  2. Perioperative outcomes of video- and robot-assisted segmentectomies.

    PubMed

    Rinieri, Philippe; Peillon, Christophe; Salaün, Mathieu; Mahieu, Julien; Bubenheim, Michael; Baste, Jean-Marc

    2016-02-01

    Video-assisted thoracic surgery appears to be technically difficult for segmentectomy. Conversely, robotic surgery could facilitate the performance of segmentectomy. The aim of this study was to compare the early results of video- and robot-assisted segmentectomies. Data were collected prospectively on videothoracoscopy from 2010 and on robotic procedures from 2013. Fifty-one patients who were candidates for minimally invasive segmentectomy were included in the study. Perioperative outcomes of video-assisted and robotic segmentectomies were compared. The minimally invasive segmentectomies included 32 video- and 16 robot-assisted procedures; 3 segmentectomies (2 video-assisted and 1 robot-assisted) were converted to lobectomies. Four conversions to thoracotomy were necessary for anatomical reason or arterial injury, with no uncontrolled bleeding in the robotic arm. There were 7 benign or infectious lesions, 9 pre-invasive lesions, 25 lung cancers, and 10 metastatic diseases. Patient characteristics, type of segment, conversion to thoracotomy, conversion to lobectomy, operative time, postoperative complications, chest tube duration, postoperative stay, and histology were similar in the video and robot groups. Estimated blood loss was significantly higher in the video group (100 vs. 50 mL, p = 0.028). The morbidity rate of minimally invasive segmentectomy was low. The short-term results of video-assisted and robot-assisted segmentectomies were similar, and more data are required to show any advantages between the two techniques. Long-term oncologic outcomes are necessary to evaluate these new surgical practices. © The Author(s) 2016.

  3. Robot assistant versus human or another robot assistant in patients undergoing laparoscopic cholecystectomy.

    PubMed

    Gurusamy, Kurinchi Selvan; Samraj, Kumarakrishnan; Fusai, Giuseppe; Davidson, Brian R

    2012-09-12

    The role of a robotic assistant in laparoscopic cholecystectomy is controversial. While some trials have shown distinct advantages of a robotic assistant over a human assistant others have not, and it is unclear which robotic assistant is best. The aims of this review are to assess the benefits and harms of a robot assistant versus human assistant or versus another robot assistant in laparoscopic cholecystectomy, and to assess whether the robot can substitute the human assistant. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded (until February 2012) for identifying the randomised clinical trials. Only randomised clinical trials (irrespective of language, blinding, or publication status) comparing robot assistants versus human assistants in laparoscopic cholecystectomy were considered for the review. Randomised clinical trials comparing different types of robot assistants were also considered for the review. Two authors independently identified the trials for inclusion and independently extracted the data. We calculated the risk ratio (RR) or mean difference (MD) with 95% confidence interval (CI) using the fixed-effect and the random-effects models based on intention-to-treat analysis, when possible, using Review Manager 5. We included six trials with 560 patients. One trial involving 129 patients did not state the number of patients randomised to the two groups. In the remaining five trials 431 patients were randomised, 212 to the robot assistant group and 219 to the human assistant group. All the trials were at high risk of bias. Mortality and morbidity were reported in only one trial with 40 patients. There was no mortality or morbidity in either group. Mortality and morbidity were not reported in the remaining trials. Quality of life or the proportion of patients who were discharged as day-patient laparoscopic cholecystectomy patients were not reported in any trial. There was no significant difference in the proportion of patients who required conversion to open cholecystectomy (2 trials; 4/63 (weighted proportion 6.4%) in the robot assistant group versus 5/70 (7.1%) in the human assistant group; RR 0.90; 95% CI 0.25 to 3.20). There was no significant difference in the operating time between the two groups (4 trials; 324 patients; MD 5.00 minutes; 95% CI -0.55 to 10.54). In one trial, about one sixth of the laparoscopic cholecystectomies in which a robot assistant was used required temporary use of a human assistant. In another trial, there was no requirement for human assistants. One trial did not report this information. It appears that there was little or no requirement for human assistants in the other three trials. There were no randomised trials comparing one type of robot versus another type of robot. Robot assisted laparoscopic cholecystectomy does not seem to offer any significant advantages over human assisted laparoscopic cholecystectomy. However, all trials had a high risk of systematic errors or bias (that is, risk of overestimation of benefit and underestimation of harm). All trials were small, with few or no outcomes. Hence, the risk of random errors (that is, play of chance) is high. Further randomised trials with low risk of bias or random errors are needed.

  4. Robot-assisted Ivor-Lewis esophagectomy with intrathoracic robot-sewn anastomosis.

    PubMed

    Jin, Runsen; Xiang, Jie; Han, Dingpei; Zhang, Yajie; Li, Hecheng

    2017-11-01

    This video clip demonstrated a performance of robot-assisted Ivor-Lewis esophagectomy with intrathoracic robot-sewn anastomosis. The patient had an esophageal mass located approximately 33 cm away from incisor, and robot-assisted Ivor-Lewis esophagectomy was applied for him. Importantly, a double-layer esophago-gastric anastomosis was made by robotic hand-sewn suture. Our early experience demonstrated that the robot-sewn intrathoracic anastomosis is feasible and safe with a lower complication rate and the absence of anastomotic leakage.

  5. Socially assistive robotics for post-stroke rehabilitation

    PubMed Central

    Matarić, Maja J; Eriksson, Jon; Feil-Seifer, David J; Winstein, Carolee J

    2007-01-01

    Background Although there is a great deal of success in rehabilitative robotics applied to patient recovery post stroke, most of the research to date has dealt with providing physical assistance. However, new rehabilitation studies support the theory that not all therapy need be hands-on. We describe a new area, called socially assistive robotics, that focuses on non-contact patient/user assistance. We demonstrate the approach with an implemented and tested post-stroke recovery robot and discuss its potential for effectiveness. Results We describe a pilot study involving an autonomous assistive mobile robot that aids stroke patient rehabilitation by providing monitoring, encouragement, and reminders. The robot navigates autonomously, monitors the patient's arm activity, and helps the patient remember to follow a rehabilitation program. We also show preliminary results from a follow-up study that focused on the role of robot physical embodiment in a rehabilitation context. Conclusion We outline and discuss future experimental designs and factors toward the development of effective socially assistive post-stroke rehabilitation robots. PMID:17309795

  6. Robot-Assisted Laparoendoscopic Single-Site Partial Nephrectomy With the Novel Da Vinci Single-Site Platform: Initial Experience

    PubMed Central

    Komninos, Christos; Tuliao, Patrick; Kim, Dae Keun; Choi, Young Deuk; Chung, Byung Ha

    2014-01-01

    Purpose To report our initial clinical cases of robotic laparoendoscopic single-site (R-LESS) partial nephrectomy (PN) performed with the use of the novel Da Vinci R-LESS platform. Materials and Methods Three patients underwent R-LESS PN from November 2013 through February 2014. Perioperative and postoperative outcomes were collected and intraoperative difficulties were noted. Results Operative time and estimated blood loss volume ranged between 100 and 110 minutes and between 50 and 500 mL, respectively. None of the patients was transfused. All cases were completed with the off-clamp technique, whereas one case required conversion to the conventional (multiport) approach because of difficulty in creating the appropriate scope for safe tumor resection. No major postoperative complications occurred, and all tumors were resected in safe margins. Length of hospital stay ranged between 3 and 7 days. The lack of EndoWrist movements, the external collisions, and the bed assistant's limited working space were noticed to be the main drawbacks of this surgical method. Conclusions Our initial experience with R-LESS PN with the novel Da Vinci platform shows that even though the procedure is feasible, it should be applied in only appropriately selected patients. However, further improvement is needed to overcome the existing limitations. PMID:24955221

  7. Experimental analysis of robot-assisted needle insertion into porcine liver.

    PubMed

    Wang, Wendong; Shi, Yikai; Goldenberg, Andrew A; Yuan, Xiaoqing; Zhang, Peng; He, Lijing; Zou, Yingjie

    2015-01-01

    How to improve placement accuracy of needle insertion into liver tissue is of paramount interest to physicians. A robot-assisted system was developed to experimentally demonstrate its advantages in needle insertion surgeries. Experiments of needle insertion into porcine liver tissue were performed with conic tip needle (diameter 8 mm) and bevel tip needle (diameter 1.5 mm) in this study. Manual operation was designed to compare the performance of the presented robot-assisted system. The real-time force curves show outstanding advantages of robot-assisted operation in improving the controllability and stability of needle insertion process by comparing manual operation. The statistics of maximum force and average force further demonstrates robot-assisted operation causes less oscillation. The difference of liver deformation created by manual operation and robot-assisted operation is very low, 1 mm for average deformation and 2 mm for maximum deformation. To conclude, the presented robot-assisted system can improve placement accuracy of needle by stably control insertion process.

  8. Robotic hair restoration.

    PubMed

    Rose, Paul T; Nusbaum, Bernard

    2014-01-01

    The latest innovation to hair restoration surgery has been the introduction of a robotic system for harvesting grafts. This system uses the follicular unit extraction/follicular isolation technique method for harvesting follicular units, which is particularly well suited to the abilities of a robotic technology. The ARTAS system analyzes images of the donor area and then a dual-chamber needle and blunt dissecting punch are used to harvest the follicular units. The robotic technology is now being used in various locations around the world. This article discusses the use of the robotic system, its capabilities, and the advantages and disadvantages of the system. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Impressions of Humanness for Android Robot may Represent an Endophenotype for Autism Spectrum Disorders.

    PubMed

    Kumazaki, Hirokazu; Warren, Zachary; Swanson, Amy; Yoshikawa, Yuichiro; Matsumoto, Yoshio; Ishiguro, Hiroshi; Sarkar, Nilanjan; Minabe, Yoshio; Kikuchi, Mitsuru

    2018-02-01

    Identification of meaningful endophenotypes may be critical to unraveling the etiology and pathophysiology of autism spectrum disorders (ASD). We investigated whether impressions of "humanness" for android robot might represent a candidate characteristic of an ASD endophenotype. We used a female type of android robot with an appearance similar to that of a real person. Significant differences in overall impressions of 'humanness' for android robot were found between adolescents with ASD and typical development (TD) controls, as well as parents of children with ASD and parents of TD controls. Our current work does suggest robotic systems could potentially play an intelligent role in dissecting ASD heterogeneity.

  10. Use of Pediatric Open, Laparoscopic and Robot-Assisted Laparoscopic Ureteral Reimplantation in the United States: 2000 to 2012.

    PubMed

    Bowen, Diana K; Faasse, Mark A; Liu, Dennis B; Gong, Edward M; Lindgren, Bruce W; Johnson, Emilie K

    2016-07-01

    We characterize the use of pediatric open, laparoscopic and robot-assisted laparoscopic ureteral reimplantation in the United States from 2000 to 2012. We used the Kids' Inpatient Database to identify patients who underwent ureteral reimplantation for primary vesicoureteral reflux. Before 2009 laparoscopic ureteral reimplantion and robot-assisted laparoscopic ureteral reimplantation were referred to together as minimally invasive ureteral reimplantation. A detailed analysis of open vs robot-assisted laparoscopic ureteral reimplantation was performed for 2009 and 2012. A total of 14,581 ureteral reimplantations were performed. The number of ureteral reimplantations yearly decreased by 14.3%. However, the proportion of minimally invasive ureteral reimplantations increased from 0.3% to 6.3%. A total of 125 robot-assisted laparoscopic ureteral reimplantations were performed in 2012 (81.2% of minimally invasive ureteral reimplantations), representing 5.1% of all ureteral reimplantations, compared to 3.8% in 2009. In 2009 and 2012 mean ± SD patient age was 5.7 ± 3.6 years for robot-assisted laparoscopic ureteral reimplantation and 4.3 ± 3.3 years for open reimplantation (p <0.0001). Mean ± SD length of hospitalization was 1.6 ± 1.3 days for robot-assisted laparoscopic ureteral reimplantation and 2.4 ± 2.6 for open reimplantation (p <0.0001). Median charges were $22,703 for open and $32,409 for robot-assisted laparoscopic ureteral reimplantation (p <0.0001). These relationships maintained significance on multivariate analyses. On multivariate analysis robot-assisted laparoscopic ureteral reimplantation use was associated with public insurance status (p = 0.04) and geographic region outside of the southern United States (p = 0.02). Only 50 of 456 hospitals used both approaches (open and robotic), and only 6 hospitals reported 5 or more robot-assisted laparoscopic ureteral reimplantations during 2012. Treatment of primary vesicoureteral reflux with ureteral reimplantation is decreasing. Robot-assisted laparoscopic ureteral reimplantation is becoming more prevalent but remains relatively uncommon. Length of stay is shorter for the robotic approach but the costs are higher. Nationally robot-assisted laparoscopic ureteral reimplantation appears to still be in the early phase of adoption and is clustered at a small number of hospitals. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Computer-assisted hip and knee arthroplasty. Navigation and active robotic systems: an evidence-based analysis.

    PubMed

    2004-01-01

    The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. NAVIGATION-ASSISTED ARTHROPLASTY: Five studies were identified that examined navigation-assisted arthroplasty.A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1)A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2)A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3)Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that "the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques."(4;5) ROBOTIC-ASSISTED ARTHROPLASTY: Four studies were identified that examined robotic-assisted arthroplasty.A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6)Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6)Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6)Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6)An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7)An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8)An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9).

  12. Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems

    PubMed Central

    2004-01-01

    Executive Summary Objective The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. The Technology Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. Review Strategy The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. Summary of Findings Navigation-Assisted Arthroplasty Five studies were identified that examined navigation-assisted arthroplasty. A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1) A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2) A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3) Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that “the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques.”(4;5) Robotic-Assisted Arthroplasty Four studies were identified that examined robotic-assisted arthroplasty. A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6) Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6) Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6) Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6) An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7) An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8) An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9) PMID:23074452

  13. A comparative direct cost analysis of pediatric urologic robot-assisted laparoscopic surgery versus open surgery: could robot-assisted surgery be less expensive?

    PubMed

    Rowe, Courtney K; Pierce, Michael W; Tecci, Katherine C; Houck, Constance S; Mandell, James; Retik, Alan B; Nguyen, Hiep T

    2012-07-01

    Cost in healthcare is an increasing and justifiable concern that impacts decisions about the introduction of new devices such as the da Vinci(®) surgical robot. Because equipment expenses represent only a portion of overall medical costs, we set out to make more specific cost comparisons between open and robot-assisted laparoscopic surgery. We performed a retrospective, observational, matched cohort study of 146 pediatric patients undergoing either open or robot-assisted laparoscopic urologic surgery from October 2004 to September 2009 at a single institution. Patients were matched based on surgery type, age, and fiscal year. Direct internal costs from the institution were used to compare the two surgery types across several procedures. Robot-assisted surgery direct costs were 11.9% (P=0.03) lower than open surgery. This cost difference was primarily because of the difference in hospital length of stay between patients undergoing open vs robot-assisted surgery (3.8 vs 1.6 days, P<0.001). Maintenance fees and equipment expenses were the primary contributors to robotic surgery costs, while open surgery costs were affected most by room and board expenses. When estimates of the indirect costs of robot purchase and maintenance were included, open surgery had a lower total cost. There were no differences in follow-up times or complication rates. Direct costs for robot-assisted surgery were significantly lower than equivalent open surgery. Factors reducing robot-assisted surgery costs included: A consistent and trained robotic surgery team, an extensive history of performing urologic robotic surgery, selection of patients for robotic surgery who otherwise would have had longer hospital stays after open surgery, and selection of procedures without a laparoscopic alternative. The high indirect costs of robot purchase and maintenance remain major factors, but could be overcome by high surgical volume and reduced prices as competitors enter the market.

  14. Human-robot interaction tests on a novel robot for gait assistance.

    PubMed

    Tagliamonte, Nevio Luigi; Sergi, Fabrizio; Carpino, Giorgio; Accoto, Dino; Guglielmelli, Eugenio

    2013-06-01

    This paper presents tests on a treadmill-based non-anthropomorphic wearable robot assisting hip and knee flexion/extension movements using compliant actuation. Validation experiments were performed on the actuators and on the robot, with specific focus on the evaluation of intrinsic backdrivability and of assistance capability. Tests on a young healthy subject were conducted. In the case of robot completely unpowered, maximum backdriving torques were found to be in the order of 10 Nm due to the robot design features (reduced swinging masses; low intrinsic mechanical impedance and high-efficiency reduction gears for the actuators). Assistance tests demonstrated that the robot can deliver torques attracting the subject towards a predicted kinematic status.

  15. On the Effectiveness of Robot-Assisted Language Learning

    ERIC Educational Resources Information Center

    Lee, Sungjin; Noh, Hyungjong; Lee, Jonghoon; Lee, Kyusong; Lee, Gary Geunbae; Sagong, Seongdae; Kim, Munsang

    2011-01-01

    This study introduces the educational assistant robots that we developed for foreign language learning and explores the effectiveness of robot-assisted language learning (RALL) which is in its early stages. To achieve this purpose, a course was designed in which students have meaningful interactions with intelligent robots in an immersive…

  16. Assistance dogs provide a useful behavioral model to enrich communicative skills of assistance robots.

    PubMed

    Gácsi, Márta; Szakadát, Sára; Miklósi, Adám

    2013-01-01

    These studies are part of a project aiming to reveal relevant aspects of human-dog interactions, which could serve as a model to design successful human-robot interactions. Presently there are no successfully commercialized assistance robots, however, assistance dogs work efficiently as partners for persons with disabilities. In Study 1, we analyzed the cooperation of 32 assistance dog-owner dyads performing a carrying task. We revealed typical behavior sequences and also differences depending on the dyads' experiences and on whether the owner was a wheelchair user. In Study 2, we investigated dogs' responses to unforeseen difficulties during a retrieving task in two contexts. Dogs displayed specific communicative and displacement behaviors, and a strong commitment to execute the insoluble task. Questionnaire data from Study 3 confirmed that these behaviors could successfully attenuate owners' disappointment. Although owners anticipated the technical competence of future assistance robots to be moderate/high, they could not imagine robots as emotional companions, which negatively affected their acceptance ratings of future robotic assistants. We propose that assistance dogs' cooperative behaviors and problem solving strategies should inspire the development of the relevant functions and social behaviors of assistance robots with limited manual and verbal skills.

  17. Association between robot-assisted surgery and resection quality in patients with colorectal cancer.

    PubMed

    Fransgaard, Tina; Pinar, Ismail; Thygesen, Lau Caspar; Gögenur, Ismail

    2018-06-01

    Resection quality after robot-assisted surgery for colorectal cancer have not previously been investigated in a nationwide study. The aim of the study was to examine the resection quality in robot-assisted versus laparoscopic surgery for colorectal cancer. Furthermore, 30-day mortality, postoperative complications, and conversion to open surgery were investigated. Patients undergoing either laparoscopic or robot-assisted surgery for colorectal cancer between 1 January 2010 and 31 December 2015 were included. The primary outcome was whether R0 resection was achieved. Secondary outcomes were 30-day mortality, postoperative complications, and conversions to laparotomy. A total of 8615 and 3934 patients had a diagnosis of colon cancer and rectal cancer respectively. Of the patients with colon cancer, 511 patients underwent robot-assisted surgery and of the patients with rectal cancer, 706 patients underwent robot-assisted surgery. In the multivariate analysis, patients with colon cancer had an odds ratio (OR) = 0.63 (95%CI 0.45-0.88) for receiving R0 resection in the robot-assisted group compared to laparoscopy. For patients with rectal cancer, the OR was 1.20 (95%CI 0.89-1.61). No difference in 30-day mortality or postoperative complications were observed. The OR of conversion to laparotomy was lower in the robot-assisted group compared to the laparoscopic group in both patients with colon - and rectal cancer. The study showed significant lower odds of receiving R0 resection in patients with colon cancer undergoing robot-assisted surgery. In patients with rectal cancer the robot-assisted surgery non-significantly increased the odds of receiving R0 resection. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Randomized controlled trial of robot-assisted gait training with dorsiflexion assistance on chronic stroke patients wearing ankle-foot-orthosis.

    PubMed

    Yeung, Ling-Fung; Ockenfeld, Corinna; Pang, Man-Kit; Wai, Hon-Wah; Soo, Oi-Yan; Li, Sheung-Wai; Tong, Kai-Yu

    2018-06-19

    Robot-assisted ankle-foot-orthosis (AFO) can provide immediate powered ankle assistance in post-stroke gait training. Our research team has developed a novel lightweight portable robot-assisted AFO which is capable of detecting walking intentions using sensor feedback of wearer's gait pattern. This study aims to investigate the therapeutic effects of robot-assisted gait training with ankle dorsiflexion assistance. This was a double-blinded randomized controlled trial. Nineteen chronic stroke patients with motor impairment at ankle participated in 20-session robot-assisted gait training for about five weeks, with 30-min over-ground walking and stair ambulation practices. Robot-assisted AFO either provided active powered ankle assistance during swing phase in Robotic Group (n = 9), or torque impedance at ankle joint as passive AFO in Sham Group (n = 10). Functional assessments were performed before and after the 20-session gait training with 3-month Follow-up. Primary outcome measure was gait independency assessed by Functional Ambulatory Category (FAC). Secondary outcome measures were clinical scores including Fugl-Meyer Assessment (FMA), Modified Ashworth Scale (MAS), Berg Balance Scale (BBS), Timed 10-Meter Walk Test (10MWT), Six-minute Walk Test (SMWT), supplemented by gait analysis. All outcome measures were performed in unassisted gait after patients had taken off the robot-assisted AFO. Repeated-measures analysis of covariance was conducted to test the group differences referenced to clinical scores before training. After 20-session robot-assisted gait training with ankle dorsiflexion assistance, the active ankle assistance in Robotic Group induced changes in gait pattern with improved gait independency (all patients FAC ≥ 5 post-training and 3-month follow-up), motor recovery, walking speed, and greater confidence in affected side loading response (vertical ground reaction force + 1.49 N/kg, peak braking force + 0.24 N/kg) with heel strike instead of flat foot touch-down at initial contact (foot tilting + 1.91°). Sham Group reported reduction in affected leg range of motion (ankle dorsiflexion - 2.36° and knee flexion - 8.48°) during swing. Robot-assisted gait training with ankle dorsiflexion assistance could improve gait independency and help stroke patients developing confidence in weight acceptance, but future development of robot-assisted AFO should consider more lightweight and custom-fit design. ClinicalTrials.gov NCT02471248 . Registered 15 June 2015 retrospectively registered.

  19. Factors affecting return of continence 3 months after robot-assisted radical prostatectomy: analysis from a large, prospective data by a single surgeon.

    PubMed

    Ko, Young Hwii; Coelho, Rafael F; Chauhan, Sanket; Sivaraman, Ananthakrishnan; Schatloff, Oscar; Cheon, Jun; Patel, Vipul R

    2012-01-01

    In this study we identified preoperative or intraoperative factors responsible for the early return of continence after robot-assisted radical prostatectomy using data from a high volume center. Data from 1,299 patients who underwent robot-assisted radical prostatectomy performed by a single surgeon from January 2008 to June 2010 were collected prospectively and analyzed retrospectively. Patients were categorized according to whether they regained continence (no pad and no urinary leakage) within 3 months and variables were then compared. A self-administered validated questionnaire (Expanded Prostate Cancer Index Composite) was used for assessment of continence status and time to recovery. Within 3 months after surgery 86.3% of patients (1,121/1,299) had recovered continence. Multivariable Cox regression analysis revealed that only age (p <0.001, hazard ratio 0.98, 95% CI 0.97-0.99) and performance of a nerve sparing procedure were independent predictors. After adjusting for age, the hazard ratio was 1.61 (95% CI 1.25-2.07, p <0.001) for partial nerve sparing and 1.44 (1.13-1.83, p = 0.003) for bilateral nerve sparing compared to the nonnerve sparing group. Median time (95% CI) to the recovery of continence was prolonged in the nonnerve sparing group compared to nerve sparing counterparts at 6 (5.12-6.88), 4 (3.60-4.40) and 5 weeks (4.70-5.30) in the nonnerve sparing, partial nerve sparing and bilateral nerve sparing groups, respectively, with log rank p <0.01. Findings from our analysis indicate that the likelihood of postoperative urinary control was significantly higher in younger patients and when a nerve sparing procedure was performed. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. [RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].

    PubMed

    Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming

    2016-02-01

    To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.

  1. Robotic Assistance by Impedance Compensation for Hand Movements While Manual Welding.

    PubMed

    Erden, Mustafa Suphi; Billard, Aude

    2016-11-01

    In this paper, we present a robotic assistance scheme which allows for impedance compensation with stiffness, damping, and mass parameters for hand manipulation tasks and we apply it to manual welding. The impedance compensation does not assume a preprogrammed hand trajectory. Rather, the intention of the human for the hand movement is estimated in real time using a smooth Kalman filter. The movement is restricted by compensatory virtual impedance in the directions perpendicular to the estimated direction of movement. With airbrush painting experiments, we test three sets of values for the impedance parameters as inspired from impedance measurements with manual welding. We apply the best of the tested sets for assistance in manual welding and perform welding experiments with professional and novice welders. We contrast three conditions: 1) welding with the robot's assistance; 2) with the robot when the robot is passive; and 3) welding without the robot. We demonstrate the effectiveness of the assistance through quantitative measures of both task performance and perceived user's satisfaction. The performance of both the novice and professional welders improves significantly with robotic assistance compared to welding with a passive robot. The assessment of user satisfaction shows that all novice and most professional welders appreciate the robotic assistance as it suppresses the tremors in the directions perpendicular to the movement for welding.

  2. Predicting Functional Recovery in Chronic Stroke Rehabilitation Using Event-Related Desynchronization-Synchronization during Robot-Assisted Movement

    PubMed Central

    Gramigna, Cristina; Franceschetti, Silvana

    2016-01-01

    Although rehabilitation robotics seems to be a promising therapy in the rehabilitation of the upper limb in stroke patients, consensus is still lacking on its additive effects. Therefore, there is a need for determining the possible success of robotic interventions on selected patients, which in turn determine the necessity for new investigating instruments supporting the treatment decision-making process and customization. The objective of the work presented in this preliminary study was to verify that fully robot assistance would not affect the physiological oscillatory cortical activity related to a functional movement in healthy subjects. Further, the clinical results following the robotic treatment of a chronic stroke patient, who positively reacted to the robotic intervention, were analyzed and discussed. First results show that there is no difference in EEG activation pattern between assisted and no-assisted movement in healthy subjects. Even more importantly, the patient's pretreatment EEG activation pattern in no-assisted movement was completely altered, while it recovered to a quasi-physiological one in robot-assisted movement. The functional improvement following treatment was large. Using pretreatment EEG recording during robot-assisted movement might be a valid approach to assess the potential ability of the patient for recovering. PMID:27057546

  3. Human likeness: cognitive and affective factors affecting adoption of robot-assisted learning systems

    NASA Astrophysics Data System (ADS)

    Yoo, Hosun; Kwon, Ohbyung; Lee, Namyeon

    2016-07-01

    With advances in robot technology, interest in robotic e-learning systems has increased. In some laboratories, experiments are being conducted with humanoid robots as artificial tutors because of their likeness to humans, the rich possibilities of using this type of media, and the multimodal interaction capabilities of these robots. The robot-assisted learning system, a special type of e-learning system, aims to increase the learner's concentration, pleasure, and learning performance dramatically. However, very few empirical studies have examined the effect on learning performance of incorporating humanoid robot technology into e-learning systems or people's willingness to accept or adopt robot-assisted learning systems. In particular, human likeness, the essential characteristic of humanoid robots as compared with conventional e-learning systems, has not been discussed in a theoretical context. Hence, the purpose of this study is to propose a theoretical model to explain the process of adoption of robot-assisted learning systems. In the proposed model, human likeness is conceptualized as a combination of media richness, multimodal interaction capabilities, and para-social relationships; these factors are considered as possible determinants of the degree to which human cognition and affection are related to the adoption of robot-assisted learning systems.

  4. Robotic Camera Assistance and Its Benefit in 1033 Traditional Laparoscopic Procedures: Prospective Clinical Trial Using a Joystick-guided Camera Holder.

    PubMed

    Holländer, Sebastian W; Klingen, Hans Joachim; Fritz, Marliese; Djalali, Peter; Birk, Dieter

    2014-11-01

    Despite advances in instruments and techniques in laparoscopic surgery, one thing remains uncomfortable: the camera assistance. The aim of this study was to investigate the benefit of a joystick-guided camera holder (SoloAssist®, Aktormed, Barbing, Germany) for laparoscopic surgery and to compare the robotic assistance to human assistance. 1033 consecutive laparoscopic procedures were performed assisted by the SoloAssist®. Failures and aborts were documented and nine surgeons were interviewed by questionnaire regarding their experiences. In 71 of 1033 procedures, robotic assistance was aborted and the procedure was continued manually, mostly because of frequent changes of position, narrow spaces, and adverse angular degrees. One case of short circuit was reported. Emergency stop was necessary in three cases due to uncontrolled movement into the abdominal cavity. Eight of nine surgeons prefer robotic to human assistance, mostly because of a steady image and self-control. The SoloAssist® robot is a reliable system for laparoscopic procedures. Emergency shutdown was necessary in only three cases. Some minor weak spots could have been identified. Most surgeons prefer robotic assistance to human assistance. We feel that the SoloAssist® makes standard laparoscopic surgery more comfortable and further development is desirable, but it cannot fully replace a human assistant.

  5. Robotic-assisted repair of iatrogenic ureteral ligation following robotic-assisted hysterectomy.

    PubMed

    Kalisvaart, Jonathan F; Finley, David S; Ornstein, David K

    2008-01-01

    Ureteral injuries, while rare, do occur during gynecologic procedures. The expansion of laparoscopic and robotic pelvic surgical procedures increases the risk of ureteral injury from these procedures and suggests a role for minimally invasive approaches to the delayed repair of ureteral injuries. We present, to our knowledge, the first case of delayed robotic-assisted ureteral deligation and ureterolysis following iatrogenic ureteral injury occurring during a robotic abdominal hysterectomy. We present a case report and review of the literature. A 57-year-old female underwent a seemingly uncomplicated robotic-assisted laparoscopic total abdominal hysterectomy and bilateral oophorectomy for symptomatic fibroids. On postoperative day 8, she presented with persistent right flank pain. Imaging studies revealed high-grade ureteral obstruction consistent with suture ligation of the right ureter. She underwent successful robotic-assisted ureteral deligation and ureterolysis. Her postoperative course was unremarkable, and she was discharged home on postoperative day 1 from the deligation. Robotic-assisted management of complications from urologic or gynecologic surgery is technically feasible. This can potentially preserve the advantages to the patient that are being seen from the initial less-invasive surgery.

  6. Robotic-arm assisted partial knee arthroplasty: a single centre experience.

    PubMed

    Marcovigi, Andrea; Zambianchi, Francesco; Sandoni, Dario; Rivi, Elisa; Catani, Fabio

    2017-06-07

    UKA has proven to be an effective surgical procedure, but its survivorship is still negatively affected by inaccuracy in component component positioning, implant and limb alignment. Robotic surgery has been introduced in order to minimize such technical errors. The aim of the present paper was to evaluate clinical and surgical outcomes after a 3 years' experience of robotic assisted UKA with the Mako Robotic Arm. Seventy-three patients undergoing  UKA with robotic instrumentation (65 medial UKAs, 8 lateral UKAs) and with a clinical follow-up of 3 -37 months were included in the present study. A complete clinical evaluation with KOOS, FJS-12 and SF-12 was administered to all patients pre and post operatively. Post-operative HKA angle and surgical time were also recorded. Mean post-operative KOOS score was 81.32 (SD 17.19), while the mean FJS-12 score was 75.51 (SD 30.12) and the mean SF-12 Physical Score 42.25 (SD 9.97). 91% to 88% of post-operative results were considered satisfactory. Only 1 UKA failure was reported (1.3%) caused by peri-prosthetic infection. In medial UKAs mean postoperative HKA angle in extension was 3.9° varus (SD 2.5°), with no case of overcorrection; in lateral UKAs mean postoperative HKA angle in extension was 1.9° valgus (SD 1.9°) with 1 case (13%) of overcorrection. Mean skin to skin surgical time decreased from 83.2 minutes (SD 13.0) to 70.0 minutes (SD 10.9) along the learning curve. Robotic UKA has provided an improvement both in clinical and technical results, determining satisfactory clinical outcomes and a low risk of post-operative complications.

  7. A Dynamic Non Energy Storing Guidance Constraint with Motion Redirection for Robot Assisted Surgery

    DTIC Science & Technology

    2016-12-01

    Abstract— Haptically enabled hands-on or tele-operated surgical robotic systems provide a unique opportunity to integrate pre- and intra... robot -assisted surgical systems aim at improving and extending human capabilities, by exploiting the advantages of robotic systems while keeping the...move during the operation. Robot -assisted beating heart surgery is an example of procedures that can benefit from dynamic constraints. Their

  8. Robotic-Assisted Knee Arthroplasty: An Overview.

    PubMed

    van der List, Jelle P; Chawla, Harshvardhan; Pearle, Andrew D

    2016-01-01

    Unicompartmental knee arthroplasty and total knee arthroplasty are reliable treatment options for osteoarthritis. In order to improve survivorship rates, variables that are intraoperatively controlled by the orthopedic surgeon are being evaluated. These variables include lower leg alignment, soft tissue balance, joint line maintenance, and tibial and femoral component alignment, size, and fixation methods. Since tighter control of these factors is associated with improved outcomes of knee arthroplasty, several computer-assisted surgery systems have been developed. These systems differ in the number and type of variables they control. Robotic-assisted systems control these aforementioned variables and, in addition, aim to improve the surgical precision of the procedure. Robotic-assisted systems are active, semi-active, or passive, depending on how independently the systems perform maneuvers. Reviewing the robotic-assisted knee arthroplasty systems, it becomes clear that these systems can accurately and reliably control the aforementioned variables. Moreover, these systems are more accurate and reliable in controlling these variables when compared to the current gold standard of conventional manual surgery. At present, few studies have assessed the survivorship and functional outcomes of robotic-assisted surgery, and no sufficiently powered studies were identified that compared survivorship or functional outcomes between robotic-assisted and conventional knee arthroplasty. Although preliminary outcomes of robotic-assisted surgery look promising, more studies are necessary to assess if the increased accuracy and reliability in controlling the surgical variables leads to better outcomes of robotic-assisted knee arthroplasty.

  9. Identification of spinal tissues loaded by manual therapy: a robot-based serial dissection technique applied in porcine motion segments.

    PubMed

    Kawchuk, Gregory N; Carrasco, Alejandro; Beecher, Grayson; Goertzen, Darrell; Prasad, Narasimha

    2010-10-15

    Serial dissection of porcine motion segments during robotic control of vertebral kinematics. To identify which spinal tissues are loaded in response to manual therapy (manipulation and mobilization) and to what magnitude. Various theoretical constructs attempt to explain how manual therapies load specific spinal tissues. By using a parallel robot to control vertebral kinematics during serial dissection, it is possible to quantify the loads experienced by discrete spinal tissues undergoing common therapeutic procedures such as manual therapy. In 9 porcine cadavers, manual therapy was provided to L3 and the kinematic response of L3-L4 recorded. The exact kinematic trajectory experienced by L3-L4 in response to manual therapy was then replayed to the isolated segment by a parallel robot equipped with a 6-axis load cell. Discrete spinal tissues were then removed and the kinematic pathway replayed. The change in forces and moments following tissue removal were considered to be those applied to that specific tissue by manual therapy. In this study, both manual therapies affected spinal tissues. The intervertebral disc experienced the greatest forces and moments arising from both manipulation and mobilization. This study is the first to identify which tissues are loaded in response to manual therapy. The observation that manual therapy loads some tissues to a much greater magnitude than others offers a possible explanation for its modest treatment effect; only conditions involving these tissues may be influenced by manual therapy. Future studies are planned to determine if manual therapy can be altered to target (or avoid) specific spinal tissues.

  10. Doing Dissections Differently: A Structured, Peer-Assisted Learning Approach to Maximizing Learning in Dissections

    ERIC Educational Resources Information Center

    Hall, Emma R.; Davis, Rachel C.; Weller, Renate; Powney, Sonya; Williams, Sarah B.

    2013-01-01

    Areas of difficulty faced by our veterinary medicine students, with respect to their learning in dissection classes, were identified. These challenges were both general adult-learning related and specific to the discipline of anatomy. Our aim was to design, implement, and evaluate a modified reciprocal peer-assisted/team-based learning…

  11. Assessment of personal care and medical robots from older adults' perspective.

    PubMed

    Goher, K M; Mansouri, N; Fadlallah, S O

    2017-01-01

    Demographic reports indicate that population of older adults is growing significantly over the world and in particular in developed nations. Consequently, there are a noticeable number of demands for certain services such as health-care systems and assistive medical robots and devices. In today's world, different types of robots play substantial roles specifically in medical sector to facilitate human life, especially older adults. Assistive medical robots and devices are created in various designs to fulfill specific needs of older adults. Though medical robots are utilized widely by senior citizens, it is dramatic to find out into what extent assistive robots satisfy their needs and expectations. This paper reviews various assessments of assistive medical robots from older adults' perspectives with the purpose of identifying senior citizen's needs, expectations, and preferences. On the other hand, these kinds of assessments inform robot designers, developers, and programmers to come up with robots fulfilling elderly's needs while improving their life quality.

  12. Does assist-as-needed upper limb robotic therapy promote participation in repetitive activity-based motor training in sub-acute stroke patients with severe paresis?

    PubMed

    Grosmaire, Anne-Gaëlle; Duret, Christophe

    2017-01-01

    Repetitive, active movement-based training promotes brain plasticity and motor recovery after stroke. Robotic therapy provides highly repetitive therapy that reduces motor impairment. However, the effect of assist-as-needed algorithms on patient participation and movement quality is not known. To analyze patient participation and motor performance during highly repetitive assist-as-needed upper limb robotic therapy in a retrospective study. Sixteen patients with sub-acute stroke carried out a 16-session upper limb robotic training program combined with usual care. The Fugl-Meyer Assessment (FMA) score was evaluated pre and post training. Robotic assistance parameters and Performance measures were compared within and across sessions. Robotic assistance did not change within-session and decreased between sessions during the training program. Motor performance did not decrease within-session and improved between sessions. Velocity-related assistance parameters improved more quickly than accuracy-related parameters. An assist-as-needed-based upper limb robotic training provided intense and repetitive rehabilitation and promoted patient participation and motor performance, facilitating motor recovery.

  13. “Five on a dice” port placement for robot-assisted thoracoscopic right upper lobectomy using robotic stapler

    PubMed Central

    Chan, Edward Y.

    2017-01-01

    Early versions of the da Vinci robot system (S and Si) have been used to perform pulmonary lung resection with severe limitations. The lack of a vascular robot stapler required the presence of a trained bedside assistant whose role was to place, manipulate and fire the stapler around major vascular structures. Thus, the techniques developed for the Si robot required a skilled bedside assistant to perform stapling of the hilar structure and manipulation of the lung. With the advent of the da Vinci Xi system with a vascular robot stapler, we postulated that we could develop a new port placement and technique to provide total control for the surgeon during the pulmonary lung resection. We found that the “five on a dice” port placement and technique allows for minimal assistance during the lobectomy with full control by the surgeon. This technique uses the full capability of the Xi robot to make the robot-assisted lobectomy a safe and ergonomic operation. PMID:29312746

  14. "Five on a dice" port placement for robot-assisted thoracoscopic right upper lobectomy using robotic stapler.

    PubMed

    Kim, Min P; Chan, Edward Y

    2017-12-01

    Early versions of the da Vinci robot system (S and Si) have been used to perform pulmonary lung resection with severe limitations. The lack of a vascular robot stapler required the presence of a trained bedside assistant whose role was to place, manipulate and fire the stapler around major vascular structures. Thus, the techniques developed for the Si robot required a skilled bedside assistant to perform stapling of the hilar structure and manipulation of the lung. With the advent of the da Vinci Xi system with a vascular robot stapler, we postulated that we could develop a new port placement and technique to provide total control for the surgeon during the pulmonary lung resection. We found that the "five on a dice" port placement and technique allows for minimal assistance during the lobectomy with full control by the surgeon. This technique uses the full capability of the Xi robot to make the robot-assisted lobectomy a safe and ergonomic operation.

  15. Robotic nephroureterectomy: a simplified approach requiring no patient repositioning or robot redocking.

    PubMed

    Zargar, Homayoun; Krishnan, Jayram; Autorino, Riccardo; Akca, Oktay; Brandao, Luis Felipe; Laydner, Humberto; Samarasekera, Dinesh; Ko, Oliver; Haber, Georges-Pascal; Kaouk, Jihad H; Stein, Robert J

    2014-10-01

    Robotic technology is increasingly adopted in urologic surgery and a variety of techniques has been described for minimally invasive treatment of upper tract urothelial cancer (UTUC). To describe a simplified surgical technique of robot-assisted nephroureterectomy (RANU) and to report our single-center surgical outcomes. Patients with history of UTUC treated with this modality between April 2010 and August 2013 were included in the analysis. Institutional review board approval was obtained. Informed consent was signed by all patients. A simplified single-step RANU not requiring repositioning or robot redocking. Lymph node dissection was performed selectively. Descriptive analysis of patients' characteristics, perioperative outcomes, histopathology, and short-term follow-up data was performed. The analysis included 31 patients (mean age: 72.4±10.6 yr; mean body mass index: 26.6±5.1kg/m(2)). Twenty-six of 30 tumors (86%) were high grade. Mean tumor size was 3.1±1.8cm. Of the 31 patients, 13 (42%) had pT3 stage disease. One periureteric positive margin was noted in a patient with bulky T3 disease. The mean number of lymph nodes removed was 9.4 (standard deviation: 5.6; range: 3-21). Two of 14 patients (14%) had positive lymph nodes on final histology. No patients required a blood transfusion. Six patients experienced complications postoperatively, with only one being a high grade (Clavien 3b) complication. Median hospital stay was 5 d. Within the follow-up period, seven patients experienced bladder recurrences and four patients developed metastatic disease. Our RANU technique eliminates the need for patient repositioning or robot redocking. This technique can be safely reproduced, with surgical outcomes comparable to other established techniques. We describe a surgical technique using the da Vinci robot for a minimally invasive treatment of patients presenting with upper tract urothelial cancer. This technique can be safely implemented with good surgical outcomes. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  16. Robot-assisted versus other types of radical prostatectomy: Population-based safety and cost comparison in Japan, 2012–2013

    PubMed Central

    Sugihara, Toru; Yasunaga, Hideo; Horiguchi, Hiromasa; Matsui, Hiroki; Fujimura, Tetsuya; Nishimatsu, Hiroaki; Fukuhara, Hiroshi; Kume, Haruki; Changhong, Yu; Kattan, Michael W; Fushimi, Kiyohide; Homma, Yukio

    2014-01-01

    In 2012, Japanese national insurance started covering robot-assisted surgery. We carried out a population-based comparison between robot-assisted and three other types of radical prostatectomy to evaluate the safety of robot-assisted prostatectomy during its initial year. We abstracted data for 7202 open, 2483 laparoscopic, 1181 minimal incision endoscopic, and 2126 robot-assisted radical prostatectomies for oncological stage T3 or less from the Diagnosis Procedure Combination database (April 2012–March 2013). Complication rate, transfusion rate, anesthesia time, postoperative length of stay, and cost were evaluated by pairwise one-to-one propensity-score matching and multivariable analyses with covariants of age, comorbidity, oncological stage, hospital volume, and hospital academic status. The proportion of robot-assisted radical prostatectomies dramatically increased from 8.6% to 24.1% during the first year. Compared with open, laparoscopic, and minimal incision endoscopic surgery, robot-assisted surgery was generally associated with a significantly lower complication rate (odds ratios, 0.25, 0.20, 0.33, respectively), autologous transfusion rate (0.04, 0.31, 0.10), homologous transfusion rate (0.16, 0.48, 0.14), lower cost excluding operation (differences, −5.1%, −1.8% [not significant], −10.8%) and shorter postoperative length of stay (–9.1%, +0.9% [not significant], –18.5%, respectively). However, robot-assisted surgery also resulted in a + 42.6% increase in anesthesia time and +52.4% increase in total cost compared with open surgery (all P < 0.05). Introduction of robotic surgery led to a dynamic change in prostate cancer surgery. Even in its initial year, robot-assisted radical prostatectomy was carried out with several favorable safety aspects compared to the conventional surgeries despite its having the longest anesthesia time and the highest cost. PMID:25183452

  17. Investigating the Effects of Robot-Assisted Therapy among Children with Autism Spectrum Disorder using Bio-markers

    NASA Astrophysics Data System (ADS)

    Bharatharaj, Jaishankar; Huang, Loulin; Al-Jumaily, Ahmed; Elara, Mohan Rajesh; Krägeloh, Chris

    2017-09-01

    Therapeutic pet robots designed to help humans with various medical conditions could play a vital role in physiological, psychological and social-interaction interventions for children with autism spectrum disorder (ASD). In this paper, we report our findings from a robot-assisted therapeutic study conducted over seven weeks to investigate the changes in stress levels of children with ASD. For this study, we used the parrot-inspired therapeutic robot, KiliRo, we developed and investigated urinary and salivary samples of participating children to report changes in stress levels before and after interacting with the robot. This is a pioneering human-robot interaction study to investigate the effects of robot-assisted therapy using salivary samples. The results show that the bio-inspired robot-assisted therapy can significantly help reduce the stress levels of children with ASD.

  18. Prospective study of robotic partial nephrectomy for renal cancer in Japan: Comparison with a historical control undergoing laparoscopic partial nephrectomy.

    PubMed

    Tanaka, Kazushi; Teishima, Jun; Takenaka, Atsushi; Shiroki, Ryoichi; Kobayashi, Yasuyuki; Hattori, Kazunori; Kanayama, Hiro-Omi; Horie, Shigeo; Yoshino, Yasushi; Fujisawa, Masato

    2018-05-01

    To evaluate the outcomes of robotic partial nephrectomy compared with those of laparoscopic partial nephrectomy for T1 renal tumors in Japanese centers. Patients with a T1 renal tumor who underwent robotic partial nephrectomy were eligible for inclusion in the present study. The primary end-point consisted of three components: a negative surgical margin, no conversion to open or laparoscopic surgery and a warm ischemia time ≤25 min. We compared data from these patients with the data from a retrospective study of laparoscopic partial nephrectomy carried out in Japan. A total of 108 patients were registered in the present study; 105 underwent robotic partial nephrectomy. The proportion of patients who met the primary end-point was 91.3% (95% confidence interval 84.1-95.9%), which was significantly higher than 23.3% in the historical data. Major complications were seen in 19 patients (18.1%). The mean change in the estimated glomerular filtration rate in the operated kidney, 180 days postoperatively, was -10.8 mL/min/1.73 m 2 (95% confidence interval -12.3-9.4%). Robotic partial nephrectomy for patients with a T1 renal tumor is a safe, feasible and more effective operative method compared with laparoscopic partial nephrectomy. It can be anticipated that robotic partial nephrectomy will become more widely used in Japan in the future. © 2018 The Japanese Urological Association.

  19. Robots to assist daily activities: views of older adults with Alzheimer's disease and their caregivers.

    PubMed

    Wang, Rosalie H; Sudhama, Aishwarya; Begum, Momotaz; Huq, Rajibul; Mihailidis, Alex

    2017-01-01

    Robots have the potential to both enable older adults with dementia to perform daily activities with greater independence, and provide support to caregivers. This study explored perspectives of older adults with Alzheimer's disease (AD) and their caregivers on robots that provide stepwise prompting to complete activities in the home. Ten dyads participated: Older adults with mild-to-moderate AD and difficulty completing activity steps, and their family caregivers. Older adults were prompted by a tele-operated robot to wash their hands in the bathroom and make a cup of tea in the kitchen. Caregivers observed interactions. Semi-structured interviews were conducted individually. Transcribed interviews were thematically analyzed. Three themes summarized responses to robot interactions: contemplating a future with assistive robots, considering opportunities with assistive robots, and reflecting on implications for social relationships. Older adults expressed opportunities for robots to help in daily activities, were open to the idea of robotic assistance, but did not want a robot. Caregivers identified numerous opportunities and were more open to robots. Several wanted a robot, if available. Positive consequences of robots in caregiving scenarios could include decreased frustration, stress, and relationship strain, and increased social interaction via the robot. A negative consequence could be decreased interaction with caregivers. Few studies have investigated in-depth perspectives of older adults with dementia and their caregivers following direct interaction with an assistive prompting robot. To fulfill the potential of robots, continued dialogue between users and developers, and consideration of robot design and caregiving relationship factors are necessary.

  20. Intelligence for Human-Assistant Planetary Surface Robots

    NASA Technical Reports Server (NTRS)

    Hirsh, Robert; Graham, Jeffrey; Tyree, Kimberly; Sierhuis, Maarten; Clancey, William J.

    2006-01-01

    The central premise in developing effective human-assistant planetary surface robots is that robotic intelligence is needed. The exact type, method, forms and/or quantity of intelligence is an open issue being explored on the ERA project, as well as others. In addition to field testing, theoretical research into this area can help provide answers on how to design future planetary robots. Many fundamental intelligence issues are discussed by Murphy [2], including (a) learning, (b) planning, (c) reasoning, (d) problem solving, (e) knowledge representation, and (f) computer vision (stereo tracking, gestures). The new "social interaction/emotional" form of intelligence that some consider critical to Human Robot Interaction (HRI) can also be addressed by human assistant planetary surface robots, as human operators feel more comfortable working with a robot when the robot is verbally (or even physically) interacting with them. Arkin [3] and Murphy are both proponents of the hybrid deliberative-reasoning/reactive-execution architecture as the best general architecture for fully realizing robot potential, and the robots discussed herein implement a design continuously progressing toward this hybrid philosophy. The remainder of this chapter will describe the challenges associated with robotic assistance to astronauts, our general research approach, the intelligence incorporated into our robots, and the results and lessons learned from over six years of testing human-assistant mobile robots in field settings relevant to planetary exploration. The chapter concludes with some key considerations for future work in this area.

  1. Object Segmentation Methods for Online Model Acquisition to Guide Robotic Grasping

    NASA Astrophysics Data System (ADS)

    Ignakov, Dmitri

    A vision system is an integral component of many autonomous robots. It enables the robot to perform essential tasks such as mapping, localization, or path planning. A vision system also assists with guiding the robot's grasping and manipulation tasks. As an increased demand is placed on service robots to operate in uncontrolled environments, advanced vision systems must be created that can function effectively in visually complex and cluttered settings. This thesis presents the development of segmentation algorithms to assist in online model acquisition for guiding robotic manipulation tasks. Specifically, the focus is placed on localizing door handles to assist in robotic door opening, and on acquiring partial object models to guide robotic grasping. First, a method for localizing a door handle of unknown geometry based on a proposed 3D segmentation method is presented. Following segmentation, localization is performed by fitting a simple box model to the segmented handle. The proposed method functions without requiring assumptions about the appearance of the handle or the door, and without a geometric model of the handle. Next, an object segmentation algorithm is developed, which combines multiple appearance (intensity and texture) and geometric (depth and curvature) cues. The algorithm is able to segment objects without utilizing any a priori appearance or geometric information in visually complex and cluttered environments. The segmentation method is based on the Conditional Random Fields (CRF) framework, and the graph cuts energy minimization technique. A simple and efficient method for initializing the proposed algorithm which overcomes graph cuts' reliance on user interaction is also developed. Finally, an improved segmentation algorithm is developed which incorporates a distance metric learning (DML) step as a means of weighing various appearance and geometric segmentation cues, allowing the method to better adapt to the available data. The improved method also models the distribution of 3D points in space as a distribution of algebraic distances from an ellipsoid fitted to the object, improving the method's ability to predict which points are likely to belong to the object or the background. Experimental validation of all methods is performed. Each method is evaluated in a realistic setting, utilizing scenarios of various complexities. Experimental results have demonstrated the effectiveness of the handle localization method, and the object segmentation methods.

  2. ROAD: domestic assistant and rehabilitation robot.

    PubMed

    Carrera, Isela; Moreno, Héctor A; Saltarén, Roque; Pérez, Carlos; Puglisi, Lisandro; Garcia, Cecilia

    2011-10-01

    This study introduces the concept design and analysis of a robotic system for the assistance and rehabilitation of disabled people. Based on the statistical data of the most common types of disabilities in Spain and other industrialized countries, the different tasks that the device must be able to perform have been determined. In this study, different robots for rehabilitation and assistance previously introduced have been reviewed. This survey is focused on those robots that assist with gait, balance and standing up. The structure of the ROAD robot presents various advantages over these robots, we discuss some of them. The performance of the proposed architecture is analyzed when it performs the sit to stand activity.

  3. General surgery residents' perception of robot-assisted procedures during surgical training.

    PubMed

    Farivar, Behzad S; Flannagan, Molly; Leitman, I Michael

    2015-01-01

    With the continued expansion of robotically assisted procedures, general surgery residents continue to receive more exposure to this new technology as part of their training. There are currently no guidelines or standardized training requirements for robot-assisted procedures during general surgical residency. The aim of this study was to assess the effect of this new technology on general surgery training from the residents' perspective. An anonymous, national, web-based survey was conducted on residents enrolled in general surgery training in 2013. The survey was sent to 240 Accreditation Council for Graduate Medical Education-approved general surgery training programs. Overall, 64% of the responding residents were men and had an average age of 29 years. Half of the responses were from postgraduate year 1 (PGY1) and PGY2 residents, and the remainder was from the PGY3 level and above. Overall, 50% of the responses were from university training programs, 32% from university-affiliated programs, and 18% from community-based programs. More than 96% of residents noted the availability of the surgical robot system at their training institution. Overall, 63% of residents indicated that they had participated in robotic surgical cases. Most responded that they had assisted in 10 or fewer robotic cases with the most frequent activities being assisting with robotic trocar placement and docking and undocking the robot. Only 18% reported experience with operating the robotic console. More senior residents (PGY3 and above) were involved in robotic cases compared with junior residents (78% vs 48%, p < 0.001). Overall, 60% of residents indicated that they received no prior education or training before their first robotic case. Approximately 64% of residents reported that formal training in robotic surgery was important in residency training and 46% of residents indicated that robotic-assisted cases interfered with resident learning. Only 11% felt that robotic-assisted cases would replace conventional laparoscopic surgery in the future. This study illustrates that although the most residents have a robot at their institution and have participated in robotic surgery cases, very few residents received formal training before participating in a robotic case. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. Segmental liver resection assisted by HIFU: tissue precauterization using a toroidal-shaped HIFU transducer

    NASA Astrophysics Data System (ADS)

    N'Djin, W. A.; Melodelima, D.; Schenone, F.; Rivoire, M.; Chapelon, J. Y.

    2010-03-01

    The development of new cauterization techniques for hepatic resection is critical for improving the safety of the procedure. Previous studies showed the feasibility of using HIFU or radiofrequency precoagulation to limit blood loss during dissection of the organ. Here we report a new therapeutic modality using high intensity focused ultrasound (HIFU) to perform a bloodless hepatic resection that could represent a promising alternative. A comparative study was performed to evaluate the interest of using this complementary tool to improve surgical resection in the liver. This study used a 3 MHz HIFU toroidal-shaped phased array transducer which allows the generation of a single conical lesion of 7 cm3 in 40 seconds. In order to minimize blood loss and dissection time, a barrier of coagulative necrosis was generated with the HIFU device before hepatectomy, by juxtaposing single conical lesions on the line of dissection. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. The parameters examined were vascular control and times of treatment. Precoagulation allowed the vascular isolation of small vessels and surgical clips were mainly used for the control of vessels>5 mm in diameter. The number of clips used per unit of liver surface dissected in RA-HIFU (0.8±0.3 cm-2) was significantly lower than in the other groups (RC: 1.6±0.4 cm-2, Control: 1.8±0.8 cm-2, p<0.01). In addition, blood loss was lower in RA-HIFU (7.4±6.5 ml.cm-2) than in RC (11.2±4.5 ml.cm-2) and Control (14.0±6.7 ml.cm-2). The time of dissection in RA-HIFU (13±5 min) was shorter than in RC (23±8 minutes) and Control (18±5 minutes). The feasibility and the efficiency of RA-HIFU using a toroidal-shaped HIFU transducer without additional devices were demonstrated. This technique enhances the resection procedure and will be able to be tested in clinic.

  5. Customized Interactive Robotic Treatment for Stroke: EMG-Triggered Therapy

    PubMed Central

    Dipietro, Laura; Ferraro, Mark; Palazzolo, Jerome Joseph; Krebs, Hermano Igo; Volpe, Bruce T.; Hogan, Neville

    2009-01-01

    A system for electromyographic (EMG) triggering of robot-assisted therapy (dubbed the EMG game) for stroke patients is presented. The onset of a patient’s attempt to move is detected by monitoring EMG in selected muscles, whereupon the robot assists her or him to perform point-to-point movements in a horizontal plane. Besides delivering customized robot-assisted therapy, the system can record signals that may be useful to better understand the process of recovery from stroke. Preliminary experiments aimed at testing the proposed system and gaining insight into the potential of EMG-triggered, robot-assisted therapy are reported. PMID:16200756

  6. Robot-assisted walking with the Lokomat: the influence of different levels of guidance force on thorax and pelvis kinematics.

    PubMed

    Swinnen, Eva; Baeyens, Jean-Pierre; Knaepen, Kristel; Michielsen, Marc; Clijsen, Ron; Beckwée, David; Kerckhofs, Eric

    2015-03-01

    Little attention has been devoted to the thorax and pelvis movements during gait. The aim of this study is to compare differences in the thorax and pelvis kinematics during unassisted walking on a treadmill and during walking with robot assistance (Lokomat-system (Hocoma, Volketswil, Switzerland)). 18 healthy persons walked on a treadmill with and without the Lokomat system at 2kmph. Three different conditions of guidance force (30%, 60% and 100%) were used during robot-assisted treadmill walking (30% body weight support). The maximal movement amplitudes of the thorax and pelvis were measured (Polhemus Liberty™ (Polhemus, Colchester, Vermont, USA) (240/16)). A repeated measurement ANOVA was conducted. Robot-assisted treadmill walking with different levels of guidance force showed significantly smaller maximal movement amplitudes for thorax and pelvis, compared to treadmill walking. Only the antero-posterior tilting of the pelvis was significantly increased during robot-assisted treadmill walking compared to treadmill walking. No significant changes of kinematic parameters were found between the different levels of guidance force. With regard to the thorax and pelvis movements, robot-assisted treadmill walking is significantly different compared to treadmill walking. It can be concluded that when using robot assistance, the thorax is stimulated in a different way than during walking without robot assistance, influencing the balance training during gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Robot-assisted hysterectomy for endometrial and cervical cancers: a systematic review.

    PubMed

    Nevis, Immaculate F; Vali, Bahareh; Higgins, Caroline; Dhalla, Irfan; Urbach, David; Bernardini, Marcus Q

    2017-03-01

    Total and radical hysterectomies are the most common treatment strategies for early-stage endometrial and cervical cancers, respectively. Surgical modalities include open surgery, laparoscopy, and more recently, minimally invasive robot-assisted surgery. We searched several electronic databases for randomized controlled trials and observational studies with a comparison group, published between 2009 and 2014. Our outcomes of interest included both perioperative and morbidity outcomes. We included 35 observational studies in this review. We did not find any randomized controlled trials. The quality of evidence for all reported outcomes was very low. For women with endometrial cancer, we found that there was a reduction in estimated blood loss between the robot-assisted surgery compared to both laparoscopy and open surgery. There was a reduction in length of hospital stay between robot-assisted surgery and open surgery but not laparoscopy. There was no difference in total lymph node removal between the three modalities. There was no difference in the rate of overall complications between the robot-assisted technique and laparoscopy. For women with cervical cancer, there were no differences in estimated blood loss or removal of lymph nodes between robot-assisted and laparoscopic procedure. Compared to laparotomy, robot-assisted hysterectomy for cervical cancer showed an overall reduction in estimated blood loss. Although robot-assisted hysterectomy is clinically effective for the treatment of both endometrial and cervical cancers, methodologically rigorous studies are lacking to draw definitive conclusions.

  8. Prospective evaluation of short-term impact and recovery of health related quality of life in men undergoing robotic assisted laparoscopic radical prostatectomy versus open radical prostatectomy.

    PubMed

    Miller, Javier; Smith, Angela; Kouba, Erik; Wallen, Eric; Pruthi, Raj S

    2007-09-01

    In the last few years there have been increasing claims that robotic assisted laparoscopic radical prostatectomy decreases short-term morbidity in patients undergoing surgical treatment for prostate cancer. However, there is surprisingly little objective evidence to support this point, which is often used to market the procedure to patients. To address this issue we prospectively evaluated patients undergoing open and robotic assisted laparoscopic radical prostatectomy at baseline and weekly through the postoperative period using a validated questionnaire. A total of 162 men undergoing radical prostatectomy, including open radical prostatectomy in 120 and robotic assisted laparoscopic radical prostatectomy in 42, for clinically localized prostate cancer completed the SF-12, version 2 Physical and Mental Health Survey Acute Form preoperatively and each week postoperatively for 6 weeks. Physical and Mental Component Scores were calculated from the questionnaires at each time point. Comparisons between the 2 surgical approaches were made at each time point. No significant differences were seen between the open and robotic assisted laparoscopic radical prostatectomy groups with regard to patient age, clinical stage or preoperative prostate specific antigen. Mean surgical blood loss was significantly higher in the open group compared to that in the robotic assisted laparoscopic group. Physical Component Scores in the robotic assisted laparoscopic group were significantly higher than those in the open cohort beginning postoperative week 1 and extending through week 6. On statistical extrapolation Physical Component Scores returned to baseline between weeks 5 and 6 postoperatively in the robotic assisted laparoscopic group and between weeks 6 and 7 in the open group. Mental Component Score scores were not statistically different between the groups except preoperatively. This study helps prospectively define short-term health related quality of life in patients undergoing robotic assisted laparoscopic vs open radical prostatectomy. Higher physical scores were seen in the robotic assisted laparoscopic group than the open group beginning postoperative week 1 and continuing weekly throughout the 6-week study period. Physical Component Score scores returned to baseline sooner in the robotic assisted laparoscopic group than in the open group.

  9. Robot-assisted versus open radical prostatectomy: the differential effect of regionalization, procedure volume and operative approach.

    PubMed

    Sammon, Jesse D; Karakiewicz, Pierre I; Sun, Maxine; Sukumar, Shyam; Ravi, Praful; Ghani, Khurshid R; Bianchi, Marco; Peabody, James O; Shariat, Shahrokh F; Perrotte, Paul; Hu, Jim C; Menon, Mani; Trinh, Quoc-Dien

    2013-04-01

    The use of robot-assisted radical prostatectomy has increased rapidly despite the absence of randomized, controlled trials showing the superiority of this approach. While recent studies suggest an advantage for perioperative complication rates, they fail to account for the volume-outcome relationship. We compared perioperative outcomes after robot-assisted and open radical prostatectomy, while considering the impact of this established relationship. Using the NIS (Nationwide Inpatient Sample), we abstracted data on patients treated with radical prostatectomy in 2009. Univariable and multivariable logistic regression analyses were done to compare the rates of blood transfusion, intraoperative and postoperative complications, prolonged length of stay, increased hospital charges and mortality between robot-assisted and open radical prostatectomy overall and across volume quartiles. An estimated 77,616 men underwent radical prostatectomy, including a robot-assisted and an open procedure in 63.9% and 36.1%, respectively. Low volume centers averaged 26.2 robot-assisted and 5.2 open cases, while very high volume centers averaged 578.8 robot-assisted and 150.2 open cases. Overall, patients treated with the robot-assisted procedure experienced a lower rate of adverse outcomes than those treated with the open procedure for all measured categories. Across equivalent volume quartiles robot-assisted radical prostatectomy outcomes were generally favorable. However, the open procedure at high volume centers resulted in a lower postoperative complication rate (OR 0.59, 95% CI 0.46-0.75), elevated hospital charges (OR 0.75, 95% CI 0.64-0.87) and a comparable blood transfusion rate (OR 1.38, 95% CI 0.93-2.02) relative to the robot-assisted procedure at low volume centers. Regionalization has occurred to a greater extent for robot-assisted than for open radical prostatectomy with an associated benefit in overall outcomes. Nonetheless, low volume institutions experienced inferior outcomes relative to the highest volume centers irrespective of approach. These findings demonstrate the importance of accounting for hospital volume when examining the benefit of a surgical technique. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Human-robot cooperative movement training: learning a novel sensory motor transformation during walking with robotic assistance-as-needed.

    PubMed

    Emken, Jeremy L; Benitez, Raul; Reinkensmeyer, David J

    2007-03-28

    A prevailing paradigm of physical rehabilitation following neurologic injury is to "assist-as-needed" in completing desired movements. Several research groups are attempting to automate this principle with robotic movement training devices and patient cooperative algorithms that encourage voluntary participation. These attempts are currently not based on computational models of motor learning. Here we assume that motor recovery from a neurologic injury can be modelled as a process of learning a novel sensory motor transformation, which allows us to study a simplified experimental protocol amenable to mathematical description. Specifically, we use a robotic force field paradigm to impose a virtual impairment on the left leg of unimpaired subjects walking on a treadmill. We then derive an "assist-as-needed" robotic training algorithm to help subjects overcome the virtual impairment and walk normally. The problem is posed as an optimization of performance error and robotic assistance. The optimal robotic movement trainer becomes an error-based controller with a forgetting factor that bounds kinematic errors while systematically reducing its assistance when those errors are small. As humans have a natural range of movement variability, we introduce an error weighting function that causes the robotic trainer to disregard this variability. We experimentally validated the controller with ten unimpaired subjects by demonstrating how it helped the subjects learn the novel sensory motor transformation necessary to counteract the virtual impairment, while also preventing them from experiencing large kinematic errors. The addition of the error weighting function allowed the robot assistance to fade to zero even though the subjects' movements were variable. We also show that in order to assist-as-needed, the robot must relax its assistance at a rate faster than that of the learning human. The assist-as-needed algorithm proposed here can limit error during the learning of a dynamic motor task. The algorithm encourages learning by decreasing its assistance as a function of the ongoing progression of movement error. This type of algorithm is well suited for helping people learn dynamic tasks for which large kinematic errors are dangerous or discouraging, and thus may prove useful for robot-assisted movement training of walking or reaching following neurologic injury.

  11. Robot-assisted Surgery for Benign Ureteral Strictures: Experience and Outcomes from Four Tertiary Care Institutions.

    PubMed

    Buffi, Nicolò Maria; Lughezzani, Giovanni; Hurle, Rodolfo; Lazzeri, Massimo; Taverna, Gianluigi; Bozzini, Giorgio; Bertolo, Riccardo; Checcucci, Enrico; Porpiglia, Francesco; Fossati, Nicola; Gandaglia, Giorgio; Larcher, Alessandro; Suardi, Nazareno; Montorsi, Francesco; Lista, Giuliana; Guazzoni, Giorgio; Mottrie, Alexandre

    2017-06-01

    Minimally invasive treatment of benign ureteral strictures is still challenging because of its technical complexity. In this context, robot-assisted surgery may overcome the limits of the laparoscopic approach. To evaluate outcomes for robotic ureteral repair in a multi-institutional cohort of patients treated for ureteropelvic junction obstruction and ureteral stricture (US) at four tertiary referral centres. This retrospective study reports data for 183 patients treated with standard robot-assisted pyeloplasty (PYP) and robotic uretero-ureterostomy (UUY) at four high-volume centres from January 2006 to September 2014. Robotic PYP and robot-assisted UUY were performed according to previously reported surgical techniques. Preoperative, intraoperative, and postoperative variables and outcomes were assessed. A descriptive statistical analysis was performed. No robot-assisted UUY cases required surgical conversion, while 2.8% of PYP cases were not completed robotically. The median operative time was 120 and 150min for robot-assisted PYP and robot-assisted UUY, respectively. No intraoperative complications were reported. The overall complication rate for all procedures was 11% (n=20) and complications were mostly of low grade. The high-grade complication rate was 2.2% (n=4). At median follow-up of 24 mo, the overall success rate was >90% for both procedures. The study limitations include its retrospective nature and the heterogeneity of the study population. Robotic surgery for benign US is safe and effective, with limited risk of high-grade complications and good intermediate-term results. In this study we review the use of robotic surgery at four different tertiary care centres in the treatment of patients affected by benign ureteral strictures. Our results demonstrate that robotic surgery is a safe alternative to the standard open approach in the treatment of ureteral strictures. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  12. Robot-Assisted Thoracic Surgery (RATS): Perioperative Nursing Professional Development Program.

    PubMed

    Sarmanian, Julie D

    2015-09-01

    Robot-assisted surgery continues to grow in popularity worldwide. Competency and training of personnel for robot-assisted thoracic surgery (RATS) is less established compared with other robot-assisted specialties. Major differences between minimally invasive approaches to thoracic surgery (eg, video-assisted thoracoscopic surgery) and RATS are presented to address a paucity of literature on the subject. Although perioperative nursing considerations are universal to all robot-assisted procedures, there are nursing consideration specific to RATS. This article provides a RATS perioperative nursing development program for RN circulators and scrub personnel. Development of perioperative nursing knowledge and skills through implementation of targeted training programs enables nurses to provide a safe surgical experience for patients undergoing RATS. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  13. A linear stepping endovascular intervention robot with variable stiffness and force sensing.

    PubMed

    He, Chengbin; Wang, Shuxin; Zuo, Siyang

    2018-05-01

    Robotic-assisted endovascular intervention surgery has attracted significant attention and interest in recent years. However, limited designs have focused on the variable stiffness mechanism of the catheter shaft. Flexible catheter needs to be partially switched to a rigid state that can hold its shape against external force to achieve a stable and effective insertion procedure. Furthermore, driving catheter in a similar way with manual procedures has the potential to make full use of the extensive experience from conventional catheter navigation. Besides driving method, force sensing is another significant factor for endovascular intervention. This paper presents a variable stiffness catheterization system that can provide stable and accurate endovascular intervention procedure with a linear stepping mechanism that has a similar operation mode to the conventional catheter navigation. A specially designed shape-memory polymer tube with water cooling structure is used to achieve variable stiffness of the catheter. Hence, four FBG sensors are attached to the catheter tip in order to monitor the tip contact force situation with temperature compensation. Experimental results show that the actuation unit is able to deliver linear and rotational motions. We have shown the feasibility of FBG force sensing to reduce the effect of temperature and detect the tip contact force. The designed catheter can change its stiffness partially, and the stiffness of the catheter can be remarkably increased in rigid state. Hence, in the rigid state, the catheter can hold its shape against a [Formula: see text] load. The prototype has also been validated with a vascular phantom, demonstrating the potential clinical value of the system. The proposed system provides important insights into the design of compact robotic-assisted catheter incorporating effective variable stiffness mechanism and real-time force sensing for intraoperative endovascular intervention.

  14. Adaptive model-based assistive control for pneumatic direct driven soft rehabilitation robots.

    PubMed

    Wilkening, Andre; Ivlev, Oleg

    2013-06-01

    Assistive behavior and inherent compliance are assumed to be the essential properties for effective robot-assisted therapy in neurological as well as in orthopedic rehabilitation. This paper presents two adaptive model-based assistive controllers for pneumatic direct driven soft rehabilitation robots that are based on separated models of the soft-robot and the patient's extremity, in order to take into account the individual patient's behavior, effort and ability during control, what is assumed to be essential to relearn lost motor functions in neurological and facilitate muscle reconstruction in orthopedic rehabilitation. The high inherent compliance of soft-actuators allows for a general human-robot interaction and provides the base for effective and dependable assistive control. An inverse model of the soft-robot with estimated parameters is used to achieve robot transparency during treatment and inverse adaptive models of the individual patient's extremity allow the controllers to learn on-line the individual patient's behavior and effort and react in a way that assist the patient only as much as needed. The effectiveness of the controllers is evaluated with unimpaired subjects using a first prototype of a soft-robot for elbow training. Advantages and disadvantages of both controllers are analyzed and discussed.

  15. Three-dimensional computer-assisted dissection of pancreatic lymphatic anatomy on human fetuses: a step toward automatic image alignment.

    PubMed

    Bardol, T; Subsol, G; Perez, M-J; Genevieve, D; Lamouroux, A; Antoine, B; Captier, G; Prudhomme, M; Bertrand, M M

    2018-05-01

    Pancreatic cancer is the fourth cause of death by cancer worldwide. Lymph node (LN) involvement is known to be the main prognostic factor. However, lymphatic anatomy is complex and only partially characterized. The aim of the study was to study the pancreatic lymphatic system using computer-assisted anatomic dissection (CAAD) technique and also to update CAAD technique by automatizing slice alignment. We dissected three human fetuses aged from 18 to 34 WA. 5-µm serial sections of duodeno-pancreas and spleen blocks were stained (hematoxylin-eosin, hematoxylin of Mayer and Masson trichrome), scanned, aligned and modeled in three dimensions. We observed a rich, diffuse but not systematized lymphatic network in the peri-pancreatic region. There was an equal distribution of LNs between the cephalic and body-tail portions. The lymphatic vascularization appeared in continuity from the celiac trunk to the distal ends of its hepatic and splenic arterial branches parallel to the nerve ramifications of the celiac plexus. We also observed a continuity between the drainage of the pancreatic head and the para-aortic region posteriorly. In view of the wealth of peri-pancreatic LNs, the number of LNs to harvest could be increased to improve nodal staging and prognostic evaluation. Pancreatic anatomy as described does not seem to be compatible with the sentinel LN procedure in pancreatic surgery. Finally, we are now able to offer an alternative to manual alignment with a semi-automated alignment.

  16. A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery

    NASA Astrophysics Data System (ADS)

    N'Djin, W. A.; Melodelima, D.; Schenone, F.; Rivoire, M.; Chapelon, J. Y.

    2009-04-01

    A toroidial-shaped HIFU medical device with integrated ultrasound imaging was developed for the treatment of colorectal liver metastasis. The HIFU toroidïal-shaped transducer contained 256-elements (working frequency: 3 MHz) and allows creating a single conical lesion of 7 cm3 in 40 seconds (Ifocal = 1700 W.cm-2). Volumes of treatment can then be significantly increase by juxtaposing single lesions. Presented here is the use of this device in an animal model as a complementary tool to improve surgical resection in the liver. A zone of coagulative necrosis before transecting the liver was performed using this device in order to minimize blood loss and dissection time during hepatectomy. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. Blood loss per dissection surface area was the main outcome parameter. Blood loss during liver transection was significantly lower in RA-HIFU (7.4±3.3 ml.cm-2) than in RC (34%) and Control (47%). The duration of transection in RA-HIFU (13±3 min) was significantly shorter than in RC (44%) and Control (28%). Precoagulation also resulted in the use of significantly fewer clips; the number of clips used per square centimetre was 50% lower in RA-HIFU (0.8±0.2 cm-2) than in the other groups.

  17. Development of robust behaviour recognition for an at-home biomonitoring robot with assistance of subject localization and enhanced visual tracking.

    PubMed

    Imamoglu, Nevrez; Dorronzoro, Enrique; Wei, Zhixuan; Shi, Huangjun; Sekine, Masashi; González, José; Gu, Dongyun; Chen, Weidong; Yu, Wenwei

    2014-01-01

    Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy.

  18. Development of Robust Behaviour Recognition for an at-Home Biomonitoring Robot with Assistance of Subject Localization and Enhanced Visual Tracking

    PubMed Central

    Imamoglu, Nevrez; Dorronzoro, Enrique; Wei, Zhixuan; Shi, Huangjun; González, José; Gu, Dongyun; Yu, Wenwei

    2014-01-01

    Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy. PMID:25587560

  19. Robotic-Assisted Thoracic Surgery for Early-Stage Lung Cancer: A Review.

    PubMed

    Brooks, Paula

    2015-07-01

    This review evaluates the benefits and disadvantages associated with the use of robotic-assisted technology in performing lobectomies in patients with early-stage lung cancer. The author conducted a literature search of Ovid®, MEDLINE®, PubMed®, and CINAHL® for articles published from 2005 to 2013. Search criteria included key terms such as robot, robotic, robotic-assisted lobectomy, and lung cancer. Of 922 articles, the author included a total of 12 research-based published studies in the analysis and incorporated the findings into an evidence table. Results showed that robotic-assisted lobectomies are feasible safe procedures for patients with stage 1A or 1B lung cancer; however, there is a steep learning curve and long-term randomized studies evaluating robotic-assisted lobectomy and conventional posterolateral thoracotomy or video-assisted thoracic lobectomy are needed. For patient safety, perioperative nurses should be aware of the length of time and experience required to perform these procedures, the costs, techniques, benefits, and disadvantages. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  20. Does robotic assistance confer an economic benefit during laparoscopic radical nephrectomy?

    PubMed

    Yang, David Y; Monn, M Francesca; Bahler, Clinton D; Sundaram, Chandru P

    2014-09-01

    While robotic assisted radical nephrectomy is safe with outcomes and complication rates comparable to those of the pure laparoscopic approach, there is little evidence of an economic or clinical benefit. From the 2009 to 2011 Nationwide Inpatient Sample database we identified patients 18 years old or older who underwent radical nephrectomy for primary renal malignancy. Robotic assisted and laparoscopic techniques were noted. Patients treated with the open technique and those with evidence of metastatic disease were excluded from analysis. Descriptive statistics were performed using the chi-square and Mann-Whitney tests, and the Student t-test. Multiple linear regression was done to examine factors associated with increased hospital costs and charges. We identified 24,312 radical nephrectomy cases for study inclusion, of which 7,787 (32%) were performed robotically. There was no demographic difference between robotic assisted and pure laparoscopic radical nephrectomy cases. Median total charges were $47,036 vs $38,068 for robotic assisted vs laparoscopic surgery (p <0.001). Median total hospital costs for robotic assisted surgery were $15,149 compared to $11,735 for laparoscopic surgery (p <0.001). There was no difference in perioperative complications or the incidence of death. Compared to the laparoscopic approach robotic assistance conferred an estimated $4,565 and $11,267 increase in hospital costs and charges, respectively, when adjusted for adapted Charlson comorbidity index score, perioperative complications and length of stay (p <0.001). Robotic assisted radical nephrectomy results in increased medical expense without improving patient morbidity. Assuming surgeon proficiency with pure laparoscopy, robotic technology should be reserved primarily for complex surgeries requiring reconstruction. Traditional laparoscopic techniques should continue to be used for routine radical nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Management of early colonic neoplasia: where are we now and where are we heading?

    PubMed

    Longcroft-Wheaton, Gaius; Bhandari, Pradeep

    2017-03-01

    There have been considerable advances in the endoscopic treatment of colorectal neoplasia. The development of endoscopic submucosal dissection and full thickness resection techniques is changing the way benign disease and early cancers are managed. This article reviews the evidence behind these new techniques and discusses where this field is likely to move in the future. Areas covered: A PubMed literature review of resection techniques for colonic neoplasia was performed. The clinical and cost effectiveness of endoscopic mucosal resection (EMR) is examined. The development of endoscopic submucosal dissection (ESD) and knife assisted resection is described and issues around training reviewed. Efficacy is compared to both EMR and transanal endoscopic microsurgery. The future is considered, including full thickness resection techniques and robotic endoscopy. Expert commentary: The perceived barriers to ESD are falling, and views that such techniques are only possible in Japan are disappearing. The key barriers to uptake will be training, and the development of educational programmes should be seen as a priority. The debate between TEMS and ESD will continue, but ESD is more flexible and cheaper. This will become less significant as the number of endoscopists trained in ESD grows and some TEMS surgeons may shift across towards ESD.

  2. Acceptance and perceived usefulness of robots to assist with activities of daily living and healthcare tasks.

    PubMed

    Hall, Amanda K; Backonja, Uba; Painter, Ian; Cakmak, Maya; Sung, Minjung; Lau, Timothy; Thompson, Hilaire J; Demiris, George

    2017-11-29

    As the number of older adults living with chronic conditions continues to rise, they will require assistance with activities of daily living (ADL) and healthcare tasks to continue living independently in their homes. One proposed solution to assist with the care needs of an aging population and a shrinking healthcare workforce is robotic technology. Using a cross-sectional survey design, we purposively sampled adults (≥18 years old) to assess generational acceptance and perceived usefulness of robots to assist with ADLs, healthcare tasks, and evaluate acceptance of robotic healthcare assistance across different settings. A total of 499 adults (age range [years] 18-98, Mean = 38.7, SD = 22.7) responded to the survey. Significant differences were found among young, middle-aged, and older adults on perceived usefulness of robots for cleaning, escorting them around town, acting as companionship, delivering meals, assessing sadness and calling for help, providing medical advice, taking vital sign assessments, and assisting with personal care (p < 0.05). The majority of younger adults reported that they would like a robot to provide healthcare assistance in the hospital, compared to middle-aged and older adults (p < 0.001). Results of this study can guide the design of robots to assist adults of all ages with useful tasks.

  3. Robotic assisted excision of a left ventricular myxoma.

    PubMed

    Hassan, Mohammed; Smith, J Michael

    2012-01-01

    We present a rare case of left ventricular myxoma discovered incidentally in an asymptomatic 16-year old male. The patient underwent the appropriate work-up and a robotic-assisted excision of the mass. The patient had an uneventful recovery and was discharged home at postoperative day 3. To our knowledge, this is the first case of robotic-assisted left ventricular myxoma excision in the literature. Robotic-assisted surgery of left ventricular myxomas is a safe and feasible method of excision.

  4. Robot-assisted intersphincteric resection facilitates an efficient sphincter-saving in patients with low rectal cancer.

    PubMed

    Kim, Jin Cheon; Lee, Jong Lyul; Alotaibi, Abdulrahman Muaod; Yoon, Yong Sik; Kim, Chan Wook; Park, In Ja

    2017-08-01

    Few investigations of robot-assisted intersphincteric resection (ISR) are presently available to support this procedure as a safe and efficient procedure. We aimed to evaluate the utility of robot-assisted ISR by comparison between ISR and abdominoperineal resection (APR) using both robot-assisted and open approaches. The 558 patients with lower rectal cancer (LRC) who underwent curative operation was enrolled between July 2010 and June 2015 to perform either by robot-assisted (ISR vs. APR = 310 vs. 34) or open approaches (144 vs. 70). Perioperative and functional outcomes including urogenital and anorectal dysfunctions were measured. Recurrence and survival were examined in 216 patients in which >3 years had elapsed after the operation. The robot-assisted approach was the most significant parameter to determine ISR achievement among potent parameters (OR = 3.467, 95% CI = 2.095-5.738, p < 0.001). Early surgical complications occurred more frequently in the open ISR group (16 vs. 7.7%, p = 0.01). The voiding and male sexual dysfunctions were significantly more frequent in the open ISR (p < 0.05). The fecal incontinence and lifestyle alteration score was greater in the open ISR than in the robot-assisted ISR at 12 and 24 months, respectively (p < 0.05). However, the 3-year cumulative rates of local recurrence and survival did not differ between the two groups. The current procedure of robot-assisted ISR replaced a significant portion of APR to achieve successful SSO via mostly transabdominal approach and double-stapled anastomosis. The robot-assisted ISR with minimal invasiveness might be a help to reduce anorectal and urogenital dysfunctions.

  5. A Comparison of Robotically Assisted Microsurgery versus Manual Microsurgery in Challenging Situations.

    PubMed

    Willems, Joost I P; Shin, Alexandra M; Shin, Delaney M; Bishop, Allen T; Shin, Alexander Y

    2016-04-01

    Microsurgery can be challenging secondary to orientation of the vessels, accessibility, or depth of the wound. Robotically assisted microsurgery reduces tremors and improves visualization and may improve the quality of anastomosis compared with traditional microsurgery. The purpose of this study was to compare robotically assisted microsurgery to traditional microsurgery in technically challenging situations with respect to time of anastomosis, quality of anastomosis, and Objective Structured Assessment of Technical Skills. Two investigators with no prior surgery or microsurgery experience performed 160 anastomoses on artificial microvessels after undergoing standardized traditional and robotically assisted microsurgery courses. Five different exposure groups were created with depths of 0, 10, and 20 cm and sidewall angles of 20 and 30 degrees. A comparison of 80 manual with 80 robotically assisted microsurgery anastomoses in different exposure groups was undertaken. The modified Objective Structured Assessment of Technical Skills scoring system, duration per anastomosis, and a subjective comfort scale were evaluated. In the most difficult exposure, Objective Structured Assessment of Technical Skills scores were similar in both groups (p = 0.98), the duration was higher in the manual group (p = 0.004), and the subjective comfort rating was higher in the robotically assisted microsurgery group (p < 0.001). In the easiest (0-cm depth, flat) exposure, Objective Structured Assessment of Technical Skills scores were higher in the manual group (p = 0.018) and the duration was longer in the robotically assisted microsurgery group (p = 0.008). Manual surgery was superior to robotically assisted microsurgery in technically easy exposures. In difficult exposures (greater depth and lower sidewall angles), however, robotically assisted microsurgery had a shorter surgery time and a higher comfort rating, with Objective Structured Assessment of Technical Skills scores similar to those assessing traditional microsurgery. Therapeutic, V.

  6. Wireless intraoral tongue control of an assistive robotic arm for individuals with tetraplegia.

    PubMed

    Andreasen Struijk, Lotte N S; Egsgaard, Line Lindhardt; Lontis, Romulus; Gaihede, Michael; Bentsen, Bo

    2017-11-06

    For an individual with tetraplegia assistive robotic arms provide a potentially invaluable opportunity for rehabilitation. However, there is a lack of available control methods to allow these individuals to fully control the assistive arms. Here we show that it is possible for an individual with tetraplegia to use the tongue to fully control all 14 movements of an assistive robotic arm in a three dimensional space using a wireless intraoral control system, thus allowing for numerous activities of daily living. We developed a tongue-based robotic control method incorporating a multi-sensor inductive tongue interface. One abled-bodied individual and one individual with tetraplegia performed a proof of concept study by controlling the robot with their tongue using direct actuator control and endpoint control, respectively. After 30 min of training, the able-bodied experimental participant tongue controlled the assistive robot to pick up a roll of tape in 80% of the attempts. Further, the individual with tetraplegia succeeded in fully tongue controlling the assistive robot to reach for and touch a roll of tape in 100% of the attempts and to pick up the roll in 50% of the attempts. Furthermore, she controlled the robot to grasp a bottle of water and pour its contents into a cup; her first functional action in 19 years. To our knowledge, this is the first time that an individual with tetraplegia has been able to fully control an assistive robotic arm using a wireless intraoral tongue interface. The tongue interface used to control the robot is currently available for control of computers and of powered wheelchairs, and the robot employed in this study is also commercially available. Therefore, the presented results may translate into available solutions within reasonable time.

  7. [Walking assist robot and its clinical application].

    PubMed

    Kakou, Hiroaki; Shitama, Hideo; Kimura, Yoshiko; Nakamoto, Yoko; Furuta, Nami; Honda, Kanae; Wada, Futoshi; Hachisuka, Kenji

    2009-06-01

    The walking assist robot was developed to improve gait disturbance in patients with severe disabilities. The robot had a trunk supporter, power generator and operating arms which held patient's lower extremities and simulated walking, a control unit, biofeedback system, and a treadmill. We applied the robot-aided gait training to three patients with severe gait disturbance induced by stroke, axonal Guillan-Barré syndrome or spinal cord injury, and the walking assist robot turned out to be effective in improving the gait disturbance.

  8. The decisive role of the patient-side surgeon in robotic surgery.

    PubMed

    Sgarbura, Olivia; Vasilescu, Catalin

    2010-12-01

    Minimally invasive technology literature is mainly concerned about the feasibility of the robotic procedures and the performance of the console surgeon. However, few of these technologies could be applied without a well-trained team. Our goal was to demonstrate that robotic surgery depends more on the patient-side assistant surgeon's abilities than has been previously reported. In our department, 280 interventions in digestive, thoracic, and gynecological surgery were performed since the acquisition of the robotic equipment. There are three teams trained in robotic surgery with three console surgeons and four certified patient-side surgeons. Four more patient-side assistants were trained at our center. Trocar placement, docking and undocking of the robot, insertion of the laparoscopic instruments, and hemostatic maneuvers with various devices were quantified and compared. Assistants trained by using animal or cadaver surgery are more comfortable with the robotic instruments handling and with docking and undocking of the robot. Assistants who finalized their residency or attend their final year are more accurate with the insertion of the laparoscopic instrument to the targeted organ and more skillful with LigaSure or clip applier devices. Interventions that require vivid participation of the assistants have shorter assistant-depending time intervals at the end of the learning curve than at the beginning. Robotic surgery is a team effort and is greatly dependant on the performance of assistant surgeons. Interventions that have the benefit of a trained team are more rapid and secure.

  9. Robotic bariatric surgery: A general review of the current status.

    PubMed

    Jung, Minoa K; Hagen, Monika E; Buchs, Nicolas C; Buehler, Leo H; Morel, Philippe

    2017-12-01

    While conventional laparoscopy is the gold standard for almost all bariatric procedures, robotic assistance holds promise for facilitating complex surgeries and improving clinical outcomes. Since the report of the first robotic-assisted bariatric procedure in 1999, numerous publications, including those reporting comparative trials and meta-analyses across bariatric procedures with a focus on robotic assistance, can be found. This article reviews the current literature and portrays the perspectives of robotic bariatric surgery. While there are substantial reports on robotic bariatric surgery currently in publication, most studies suffer from low levels of evidence. As such, although robotics technology is without a doubt superior to conventional laparoscopy, the precise role of robotics in bariatric surgery is not yet clear. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Robotic instrumentation: Evolution and microsurgical applications

    PubMed Central

    Parekattil, Sijo J.; Moran, Michael E.

    2010-01-01

    This article presents a review of the history and evolution of robotic instrumentation and its applications in urology. A timeline for the evolution of robotic instrumentation is presented to better facilitate an understanding of our current-day applications. Some new directions including robotic microsurgical applications (robotic assisted denervation of the spermatic cord for chronic orchialgia and robotic assisted vasectomy reversal) are presented. There is a paucity of prospective comparative effectiveness studies for a number of robotic applications. However, right or wrong, human nature has always led to our infatuation with the concept of using tools to meet our needs. This chapter is a brief tribute to where we have come from and where we may be potentially heading in the field of robotic assisted urologic surgery. PMID:21116362

  11. Robotic Fish to Aid Animal Behavior Studies and Informal Science Learning

    NASA Astrophysics Data System (ADS)

    Phamduy, Paul

    The application of robotic fish in the fields of animal behavior and informal science learning are new and relatively untapped. In the context of animal behavior studies, robotic fish offers a consistent and customizable stimulus that could contribute to dissect the determinants of social behavior. In the realm of informal science learning, robotic fish are gaining momentum for the possibility of educating the general public simultaneously on fish physiology and underwater robotics. In this dissertation, the design and development of a number of robotic fish platforms and prototypes and their application in animal behavioral studies and informal science learning settings are presented. Robotic platforms for animal behavioral studies focused on the utilization replica or same scale prototypes. A novel robotic fish platform, featuring a three-dimensional swimming multi-linked robotic fish, was developed with three control modes varying in the level of robot autonomy offered. This platform was deployed at numerous science festivals and science centers, to obtain data on visitor engagement and experience.

  12. Movement Anticipation and EEG: Implications for BCI-Contingent Robot Therapy

    PubMed Central

    Norman, Sumner L.; Dennison, Mark; Wolbrecht, Eric; Cramer, Steven C.; Srinivasan, Ramesh; Reinkensmeyer, David J.

    2017-01-01

    Brain-computer interfacing is a technology that has the potential to improve patient engagement in robot-assisted rehabilitation therapy. For example, movement intention reduces mu (8-13 Hz) oscillation amplitude over the sensorimotor cortex, a phenomenon referred to as event-related desynchronization (ERD). In an ERD-contingent assistance paradigm, initial BCI-enhanced robotic therapy studies have used ERD to provide robotic assistance for movement. Here we investigated how ERD changed as a function of audio-visual stimuli, overt movement from the participant, and robotic assistance. Twelve unimpaired subjects played a computer game designed for rehabilitation therapy with their fingers using the FINGER robotic exoskeleton. In the game, the participant and robot matched movement timing to audio-visual stimuli in the form of notes approaching a target on the screen set to the consistent beat of popular music. The audio-visual stimulation of the game alone did not cause ERD, before or after training. In contrast, overt movement by the subject caused ERD, whether or not the robot assisted the finger movement. Notably, ERD was also present when the subjects remained passive and the robot moved their fingers to play the game. This ERD occurred in anticipation of the passive finger movement with similar onset timing as for the overt movement conditions. These results demonstrate that ERD can be contingent on expectation of robotic assistance; that is, the brain generates an anticipatory ERD in expectation of a robot-imposed but predictable movement. This is a caveat that should be considered in designing BCIs for enhancing patient effort in roboticallyassisted therapy. PMID:26891487

  13. Evaluation of upper extremity robot-assistances in subacute and chronic stroke subjects.

    PubMed

    Ziherl, Jaka; Novak, Domen; Olenšek, Andrej; Mihelj, Matjaž; Munih, Marko

    2010-10-18

    Robotic systems are becoming increasingly common in upper extremity stroke rehabilitation. Recent studies have already shown that the use of rehabilitation robots can improve recovery. This paper evaluates the effect of different modes of robot-assistances in a complex virtual environment on the subjects' ability to complete the task as well as on various haptic parameters arising from the human-robot interaction. The MIMICS multimodal system that includes the haptic robot HapticMaster and a dynamic virtual environment is used. The goal of the task is to catch a ball that rolls down a sloped table and place it in a basket above the table. Our study examines the influence of catching assistance, pick-and-place movement assistance and grasping assistance on the catching efficiency, placing efficiency and on movement-dependent parameters: mean reaching forces, deviation error, mechanical work and correlation between the grasping force and the load force. The results with groups of subjects (23 subacute hemiparetic subjects, 10 chronic hemiparetic subjects and 23 control subjects) showed that the assistance raises the catching efficiency and pick-and-place efficiency. The pick-and-place movement assistance greatly limits the movements of the subject and results in decreased work toward the basket. The correlation between the load force and the grasping force exists in a certain phase of the movement. The results also showed that the stroke subjects without assistance and the control subjects performed similarly. The robot-assistances used in the study were found to be a possible way to raise the catching efficiency and efficiency of the pick-and-place movements in subacute and chronic subjects. The observed movement parameters showed that robot-assistances we used for our virtual task should be improved to maximize physical activity.

  14. Acceptance of an assistive robot in older adults: a mixed-method study of human-robot interaction over a 1-month period in the Living Lab setting.

    PubMed

    Wu, Ya-Huei; Wrobel, Jérémy; Cornuet, Mélanie; Kerhervé, Hélène; Damnée, Souad; Rigaud, Anne-Sophie

    2014-01-01

    There is growing interest in investigating acceptance of robots, which are increasingly being proposed as one form of assistive technology to support older adults, maintain their independence, and enhance their well-being. In the present study, we aimed to observe robot-acceptance in older adults, particularly subsequent to a 1-month direct experience with a robot. Six older adults with mild cognitive impairment (MCI) and five cognitively intact healthy (CIH) older adults were recruited. Participants interacted with an assistive robot in the Living Lab once a week for 4 weeks. After being shown how to use the robot, participants performed tasks to simulate robot use in everyday life. Mixed methods, comprising a robot-acceptance questionnaire, semistructured interviews, usability-performance measures, and a focus group, were used. Both CIH and MCI subjects were able to learn how to use the robot. However, MCI subjects needed more time to perform tasks after a 1-week period of not using the robot. Both groups rated similarly on the robot-acceptance questionnaire. They showed low intention to use the robot, as well as negative attitudes toward and negative images of this device. They did not perceive it as useful in their daily life. However, they found it easy to use, amusing, and not threatening. In addition, social influence was perceived as powerful on robot adoption. Direct experience with the robot did not change the way the participants rated robots in their acceptance questionnaire. We identified several barriers to robot-acceptance, including older adults' uneasiness with technology, feeling of stigmatization, and ethical/societal issues associated with robot use. It is important to destigmatize images of assistive robots to facilitate their acceptance. Universal design aiming to increase the market for and production of products that are usable by everyone (to the greatest extent possible) might help to destigmatize assistive devices.

  15. Acceptance of an assistive robot in older adults: a mixed-method study of human–robot interaction over a 1-month period in the Living Lab setting

    PubMed Central

    Wu, Ya-Huei; Wrobel, Jérémy; Cornuet, Mélanie; Kerhervé, Hélène; Damnée, Souad; Rigaud, Anne-Sophie

    2014-01-01

    Background There is growing interest in investigating acceptance of robots, which are increasingly being proposed as one form of assistive technology to support older adults, maintain their independence, and enhance their well-being. In the present study, we aimed to observe robot-acceptance in older adults, particularly subsequent to a 1-month direct experience with a robot. Subjects and methods Six older adults with mild cognitive impairment (MCI) and five cognitively intact healthy (CIH) older adults were recruited. Participants interacted with an assistive robot in the Living Lab once a week for 4 weeks. After being shown how to use the robot, participants performed tasks to simulate robot use in everyday life. Mixed methods, comprising a robot-acceptance questionnaire, semistructured interviews, usability-performance measures, and a focus group, were used. Results Both CIH and MCI subjects were able to learn how to use the robot. However, MCI subjects needed more time to perform tasks after a 1-week period of not using the robot. Both groups rated similarly on the robot-acceptance questionnaire. They showed low intention to use the robot, as well as negative attitudes toward and negative images of this device. They did not perceive it as useful in their daily life. However, they found it easy to use, amusing, and not threatening. In addition, social influence was perceived as powerful on robot adoption. Direct experience with the robot did not change the way the participants rated robots in their acceptance questionnaire. We identified several barriers to robot-acceptance, including older adults’ uneasiness with technology, feeling of stigmatization, and ethical/societal issues associated with robot use. Conclusion It is important to destigmatize images of assistive robots to facilitate their acceptance. Universal design aiming to increase the market for and production of products that are usable by everyone (to the greatest extent possible) might help to destigmatize assistive devices. PMID:24855349

  16. Robotic Surgical System for Radical Prostatectomy: A Health Technology Assessment

    PubMed Central

    Wang, Myra; Xie, Xuanqian; Wells, David; Higgins, Caroline

    2017-01-01

    Background Prostate cancer is the second most common type of cancer in Canadian men. Radical prostatectomy is one of the treatment options available, and involves removing the prostate gland and surrounding tissues. In recent years, surgeons have begun to use robot-assisted radical prostatectomy more frequently. We aimed to determine the clinical benefits and harms of the robotic surgical system for radical prostatectomy (robot-assisted radical prostatectomy) compared with the open and laparoscopic surgical methods. We also assessed the cost-effectiveness of robot-assisted versus open radical prostatectomy in patients with clinically localized prostate cancer in Ontario. Methods We performed a literature search and included prospective comparative studies that examined robot-assisted versus open or laparoscopic radical prostatectomy for prostate cancer. The outcomes of interest were perioperative, functional, and oncological. The quality of the body of evidence was examined according to the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) Working Group criteria. We also conducted a cost–utility analysis with a 1-year time horizon. The potential long-term benefits of robot-assisted radical prostatectomy for functional and oncological outcomes were also evaluated in a 10-year Markov model in scenario analyses. In addition, we conducted a budget impact analysis to estimate the additional costs to the provincial budget if the adoption of robot-assisted radical prostatectomy were to increase in the next 5 years. A needs assessment determined that the published literature on patient perspectives was relatively well developed, and that direct patient engagement would add relatively little new information. Results Compared with the open approach, we found robot-assisted radical prostatectomy reduced length of stay and blood loss (moderate quality evidence) but had no difference or inconclusive results for functional and oncological outcomes (low to moderate quality evidence). Compared with laparoscopic radical prostatectomy, robot-assisted radical prostatectomy had no difference in perioperative, functional, and oncological outcomes (low to moderate quality evidence). Compared with open radical prostatectomy, our best estimates suggested that robot-assisted prostatectomy was associated with higher costs ($6,234) and a small gain in quality-adjusted life-years (QALYs) (0.0012). The best estimate of the incremental cost-effectiveness ratio (ICER) was $5.2 million per QALY gained. However, if robot-assisted radical prostatectomy were assumed to have substantially better long-term functional and oncological outcomes, the ICER might be as low as $83,921 per QALY gained. We estimated the annual budget impact to be $0.8 million to $3.4 million over the next 5 years. Conclusions There is no high-quality evidence that robot-assisted radical prostatectomy improves functional and oncological outcomes compared with open and laparoscopic approaches. However, compared with open radical prostatectomy, the costs of using the robotic system are relatively large while the health benefits are relatively small. PMID:28744334

  17. Does haptic robot-assisted total hip arthroplasty better restore native acetabular and femoral anatomy?

    PubMed

    Tsai, Tsung-Yuan; Dimitriou, Dimitris; Li, Jing-Sheng; Kwon, Young-Min

    2016-06-01

    The objective was to evaluate whether total hip arthroplasty (THA) using haptic robot assistance restores hip geometry better than the free-hand technique. Twelve robot-assisted and 14 free-hand unilateral THA patients underwent CT scan for three-dimensional (3D) hip models. The anteversion, inclination and hip joint centre locations of the native and implanted hips in each patient were quantified and compared. Significant increase of combined anteversion by 19.1 ± 11.7° and 23.5 ± 23.6° and decrease of cup inclination by 16.5 ± 6.0° and 10.2 ± 6.8° were observed in the robot-assisted and the free-hand THAs, respectively. Less variation in the difference of the component orientations (max 11.1 vs 18.3°) and the femoral head centre (max 4.5 vs 6.3 mm) were found in the robot-assisted group. This study demonstrated that neither robot-assisted nor free-hand THAs had fully restored native hip geometry. However, the higher precision of the robot-assisted THA suggested that it has potential utility in restoring the native hip geometry. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Human-robot cooperative movement training: Learning a novel sensory motor transformation during walking with robotic assistance-as-needed

    PubMed Central

    Emken, Jeremy L; Benitez, Raul; Reinkensmeyer, David J

    2007-01-01

    Background A prevailing paradigm of physical rehabilitation following neurologic injury is to "assist-as-needed" in completing desired movements. Several research groups are attempting to automate this principle with robotic movement training devices and patient cooperative algorithms that encourage voluntary participation. These attempts are currently not based on computational models of motor learning. Methods Here we assume that motor recovery from a neurologic injury can be modelled as a process of learning a novel sensory motor transformation, which allows us to study a simplified experimental protocol amenable to mathematical description. Specifically, we use a robotic force field paradigm to impose a virtual impairment on the left leg of unimpaired subjects walking on a treadmill. We then derive an "assist-as-needed" robotic training algorithm to help subjects overcome the virtual impairment and walk normally. The problem is posed as an optimization of performance error and robotic assistance. The optimal robotic movement trainer becomes an error-based controller with a forgetting factor that bounds kinematic errors while systematically reducing its assistance when those errors are small. As humans have a natural range of movement variability, we introduce an error weighting function that causes the robotic trainer to disregard this variability. Results We experimentally validated the controller with ten unimpaired subjects by demonstrating how it helped the subjects learn the novel sensory motor transformation necessary to counteract the virtual impairment, while also preventing them from experiencing large kinematic errors. The addition of the error weighting function allowed the robot assistance to fade to zero even though the subjects' movements were variable. We also show that in order to assist-as-needed, the robot must relax its assistance at a rate faster than that of the learning human. Conclusion The assist-as-needed algorithm proposed here can limit error during the learning of a dynamic motor task. The algorithm encourages learning by decreasing its assistance as a function of the ongoing progression of movement error. This type of algorithm is well suited for helping people learn dynamic tasks for which large kinematic errors are dangerous or discouraging, and thus may prove useful for robot-assisted movement training of walking or reaching following neurologic injury. PMID:17391527

  19. Retzius space reconstruction following transperitoneal laparoscopic robot-assisted radical prostatectomy: does it have any added value?

    PubMed

    Abu-Ghanem, Yasmin; Dotan, Zohar; Ramon, Jacob; Zilberman, Dorit E

    2017-11-27

    Retzius space sparing (RSS) during laparoscopic robot-assisted radical prostatectomy (RALP) has been offered as an approach that reduces perioperative complications and enables faster gaining of full urinary continence due to bladder anatomy preservation. Retro and transperitoneal techniques have been proposed, whereby RSS has been implemented. We sought to explore whether Retzius space reconstruction (RSR) following transperitoneal RALP will be an advantageous step as well. A prospective registry database of 102 consecutive transperitoneal RALP cases performed by a single surgeon was reviewed. The Retzius space had been opened by dissecting the bladder away from the anterior abdominal wall to the level of both internal rings. In the last 51 cases (RSR group), the peritoneal layer had been sutured back, thus repositioning the bladder back to the anterior abdominal wall and reconstructing the Retzius space. Perioperative factors were analyzed and compared between the two groups. Demographic and perioperative data did not differ between the two groups. RSR group demonstrated shorter length of stay (LOS) compared with the control group (p = 0.01), as well as faster urinary continence recovery (i.e., 0 pads) (p = 0.01). Moreover, lower numbers of Clavien-Dindo class 3 complications and 12 mm port-site hernias (p = 0.03) were seen in the RSR group compared with the control group. RSR following transperitoneal RALP is a simple and efficient step that potentially reduces early and late post-operative complications, shortens LOS and accelerates full urinary continence.

  20. Acceptance and Attitudes Toward a Human-like Socially Assistive Robot by Older Adults.

    PubMed

    Louie, Wing-Yue Geoffrey; McColl, Derek; Nejat, Goldie

    2014-01-01

    Recent studies have shown that cognitive and social interventions are crucial to the overall health of older adults including their psychological, cognitive, and physical well-being. However, due to the rapidly growing elderly population of the world, the resources and people to provide these interventions is lacking. Our work focuses on the use of social robotic technologies to provide person-centered cognitive interventions. In this article, we investigate the acceptance and attitudes of older adults toward the human-like expressive socially assistive robot Brian 2.1 in order to determine if the robot's human-like assistive and social characteristics would promote the use of the robot as a cognitive and social interaction tool to aid with activities of daily living. The results of a robot acceptance questionnaire administered during a robot demonstration session with a group of 46 elderly adults showed that the majority of the individuals had positive attitudes toward the socially assistive robot and its intended applications.

  1. Cost-analysis of robotic-assisted laparoscopic hysterectomy versus total abdominal hysterectomy for women with endometrial cancer and atypical complex hyperplasia.

    PubMed

    Herling, Suzanne F; Palle, Connie; Møller, Ann M; Thomsen, Thordis; Sørensen, Jan

    2016-03-01

    The aim of this study was to analyse the hospital cost of treatment with robotic-assisted laparoscopic hysterectomy and total abdominal hysterectomy for women with endometrial cancer or atypical complex hyperplasia and to identify differences in resource use and cost. This cost analysis was based on two cohorts: women treated with robotic-assisted laparoscopic hysterectomy (n = 202) or with total abdominal hysterectomy (n = 158) at Copenhagen University Hospital, Herlev, Denmark. We conducted an activity-based cost analysis including consumables and healthcare professionals' salaries. As cost-drivers we included severe complications, duration of surgery, anesthesia and stay at the post-anesthetic care unit, as well as number of hospital bed-days. Ordinary least-squares regression was used to explore the cost variation. The primary outcome was cost difference in Danish kroner between total abdominal hysterectomy and robotic-assisted laparoscopic hysterectomy. The average cost of consumables was 12,642 Danish kroner more expensive per patient for robotic-assisted laparoscopic hysterectomy than for total abdominal hysterectomy (2014 price level: 1€ = 7.50 Danish kroner). When including all cost-drivers, the analysis showed that the robotic-assisted laparoscopic hysterectomy procedure was 9386 Danish kroner (17%) cheaper than the total abdominal hysterectomy (p = 0.003). When the robot investment was included, the cost difference reduced to 4053 Danish kroner (robotic-assisted laparoscopic hysterectomy was 7% cheaper than total abdominal hysterectomy) (p = 0.20). Increasing age and Type 2 diabetes appeared to influence the overall costs. For women with endometrial cancer or atypical complex hyperplasia, robotic-assisted laparoscopic hysterectomy was cheaper than total abdominal hysterectomy, mostly due to fewer complications and shorter length of hospital stay. © 2015 Nordic Federation of Societies of Obstetrics and Gynecology.

  2. Artificial urinary sphincter implantation in women with stress urinary incontinence: preliminary comparison of robot-assisted and open approaches.

    PubMed

    Peyronnet, Benoit; Vincendeau, Sébastien; Tondut, Lauranne; Bensalah, Karim; Damphousse, Mireille; Manunta, Andréa

    2016-03-01

    We aimed to compare outcomes of open and robot-assisted artificial urinary sphincter (AUS) implantation in female patients. The charts of all female patients who underwent an AUS implantation between 2008 and 2014 in a single center were retrospectively reviewed. From 2008 to 2012, AUS were implanted using an open approach and from 2013 to 2014 using a robot-assisted approach. Perioperative and functional parameters were compared between groups. The primary endpoint was continence status. Twenty-four women were assessed: 16 in the open group and eight in the robot-assisted group. Three patients had neurogenic stress urinary incontinence. Most patients had undergone previous procedures for urinary incontinence (15 in the open group and seven in the robotic group). Mean operative time was similar in both groups (214 vs. 211 min; p = 0.90). Postoperative complicationsrate was lower in the robot-assisted group (25 vs. 75 %; p = 0.02). There was a trend toward a lower intraoperative complication rate (37.5 vs. 62.5 %; p = 0.25), decreased blood loss (17 ml vs. 275 ml; p = 0.22), and shorter length of stay (3.5 vs. 9.3 days; p = 0.09) in the robot-assisted group. Continence rates were comparable in both groups (75 vs. 68.8 %; p = 0.75). Three AUS explantations were needed in the open group (18.8 %) compared with one in the robot-assisted group (12.5 %; p = 0.70). In female patients, the robot-assisted approach compared with open AUS implantation could decrease intraoperative and postoperative complication rates, length of hospital stay, and blood loss.

  3. Robot assistance of motor learning: A neuro-cognitive perspective.

    PubMed

    Heuer, Herbert; Lüttgen, Jenna

    2015-09-01

    The last several years have seen a number of approaches to robot assistance of motor learning. Experimental studies have produced a range of findings from beneficial effects through null-effects to detrimental effects of robot assistance. In this review we seek an answer to the question under which conditions which outcomes should be expected. For this purpose we derive tentative predictions based on a classification of learning tasks in terms of the products of learning, the mechanisms involved, and the modulation of these mechanisms by robot assistance. Consistent with these predictions, the learning of dynamic features of trajectories is facilitated and the learning of kinematic and dynamic transformations is impeded by robotic guidance, whereas the learning of dynamic transformations can profit from robot assistance with error-amplifying forces. Deviating from the predictions, learning of spatial features of trajectories is impeded by haptic guidance, but can be facilitated by divergent force fields. The deviations point to the existence of additional effects of robot assistance beyond the modulation of learning mechanisms, e.g., the induction of a passive role of the motor system during practice with haptic guidance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Application of robotics in gastrointestinal endoscopy: A review

    PubMed Central

    Yeung, Baldwin Po Man; Chiu, Philip Wai Yan

    2016-01-01

    Multiple robotic flexible endoscope platforms have been developed based on cross specialty collaboration between engineers and medical doctors. However, significant number of these platforms have been developed for the natural orifice transluminal endoscopic surgery paradigm. Increasing amount of evidence suggest the focus of development should be placed on advanced endolumenal procedures such as endoscopic submucosal dissection instead. A thorough literature analysis was performed to assess the current status of robotic flexible endoscopic platforms designed for advanced endolumenal procedures. Current efforts are mainly focused on robotic locomotion and robotic instrument control. In the future, advances in actuation and servoing technology, optical analysis, augmented reality and wireless power transmission technology will no doubt further advance the field of robotic endoscopy. Globally, health systems have become increasingly budget conscious; widespread acceptance of robotic endoscopy will depend on careful design to ensure its delivery of a cost effective service. PMID:26855540

  5. Robotic learning from demonstration of therapist's time-varying assistance to a patient in trajectory-following tasks.

    PubMed

    Najafi, Mohammad; Adams, Kim; Tavakoli, Mahdi

    2017-07-01

    The number of people with physical disabilities and impaired motion control is increasing. Consequently, there is a growing demand for intelligent assistive robotic systems to cooperate with people with disability and help them carry out different tasks. To this end, our group has pioneered the use of robot learning from demonstration (RLfD) techniques, which eliminate the need for task-specific robot programming, in robotic rehabilitation and assistive technologies settings. First, in the demonstration phase, the therapist (or in general, a helper) provides an intervention (typically assistance) and cooperatively performs a task with a patient several times. The demonstrated motion is modelled by a statistical RLfD algorithm, which will later be used in the robot controllers to reproduce a similar intervention robotically. In this paper, by proposing a Tangential-Normal Varying-Impedance Controller (TNVIC), the robotic manipulator not only follows the therapist's demonstrated motion, but also mimics his/her interaction impedance during the therapeutic/assistive intervention. The feasibility and efficacy of the proposed framework are evaluated by conducting an experiment involving a healthy adult with cerebral palsy symptoms being induced using transcutaneous electrical nerve stimulation.

  6. Knowledge assistant for robotic environmental characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feddema, J.; Rivera, J.; Tucker, S.

    1996-08-01

    A prototype sensor fusion framework called the {open_quotes}Knowledge Assistant{close_quotes} has been developed and tested on a gantry robot at Sandia National Laboratories. This Knowledge Assistant guides the robot operator during the planning, execution, and post analysis stages of the characterization process. During the planning stage, the Knowledge Assistant suggests robot paths and speeds based on knowledge of sensors available and their physical characteristics. During execution, the Knowledge Assistant coordinates the collection of data through a data acquisition {open_quotes}specialist.{close_quotes} During execution and postanalysis, the Knowledge Assistant sends raw data to other {open_quotes}specialists,{close_quotes} which include statistical pattern recognition software, a neural network,more » and model-based search software. After the specialists return their results, the Knowledge Assistant consolidates the information and returns a report to the robot control system where the sensed objects and their attributes (e.g., estimated dimensions, weight, material composition, etc.) are displayed in the world model. This report highlights the major components of this system.« less

  7. Control of robot assistant for rehabilitation of upper extremities.

    PubMed

    Kostić, Miloš D; Popović, Mirjana B; Popović, Dejan B

    2012-01-01

    The assisted movement in humans with paresis of upper extremities is becoming popular for neurorehabilitation. We propose a novel method for trajectory selection and assistance control. This paper presents simulation of a planar two degrees of freedom robot that assists horizontal movement of the hand. The control assumes that during the exercise the hand needs to follow healthy alike trajectories. The robot is assumed to provide minimal assistance and operate as a teacher of the movement.

  8. Robotic Assistance for Training Finger Movement Using a Hebbian Model: A Randomized Controlled Trial.

    PubMed

    Rowe, Justin B; Chan, Vicky; Ingemanson, Morgan L; Cramer, Steven C; Wolbrecht, Eric T; Reinkensmeyer, David J

    2017-08-01

    Robots that physically assist movement are increasingly used in rehabilitation therapy after stroke, yet some studies suggest robotic assistance discourages effort and reduces motor learning. To determine the therapeutic effects of high and low levels of robotic assistance during finger training. We designed a protocol that varied the amount of robotic assistance while controlling the number, amplitude, and exerted effort of training movements. Participants (n = 30) with a chronic stroke and moderate hemiparesis (average Box and Blocks Test 32 ± 18 and upper extremity Fugl-Meyer score 46 ± 12) actively moved their index and middle fingers to targets to play a musical game similar to GuitarHero 3 h/wk for 3 weeks. The participants were randomized to receive high assistance (causing 82% success at hitting targets) or low assistance (55% success). Participants performed ~8000 movements during 9 training sessions. Both groups improved significantly at the 1-month follow-up on functional and impairment-based motor outcomes, on depression scores, and on self-efficacy of hand function, with no difference between groups in the primary endpoint (change in Box and Blocks). High assistance boosted motivation, as well as secondary motor outcomes (Fugl-Meyer and Lateral Pinch Strength)-particularly for individuals with more severe finger motor deficits. Individuals with impaired finger proprioception at baseline benefited less from the training. Robot-assisted training can promote key psychological outcomes known to modulate motor learning and retention. Furthermore, the therapeutic effectiveness of robotic assistance appears to derive at least in part from proprioceptive stimulation, consistent with a Hebbian plasticity model.

  9. Virtual modeling of robot-assisted manipulations in abdominal surgery.

    PubMed

    Berelavichus, Stanislav V; Karmazanovsky, Grigory G; Shirokov, Vadim S; Kubyshkin, Valeriy A; Kriger, Andrey G; Kondratyev, Evgeny V; Zakharova, Olga P

    2012-06-27

    To determine the effectiveness of using multidetector computed tomography (MDCT) data in preoperative planning of robot-assisted surgery. Fourteen patients indicated for surgery underwent MDCT using 64 and 256-slice MDCT. Before the examination, a specially constructed navigation net was placed on the patient's anterior abdominal wall. Processing of MDCT data was performed on a Brilliance Workspace 4 (Philips). Virtual vectors that imitate robotic and assistant ports were placed on the anterior abdominal wall of the 3D model of the patient, considering the individual anatomy of the patient and the technical capabilities of robotic arms. Sites for location of the ports were directed by projection on the roentgen-positive tags of the navigation net. There were no complications observed during surgery or in the post-operative period. We were able to reduce robotic arm interference during surgery. The surgical area was optimal for robotic and assistant manipulators without any need for reinstallation of the trocars. This method allows modeling of the main steps in robot-assisted intervention, optimizing operation of the manipulator and lowering the risk of injuries to internal organs.

  10. Robotic assisted andrological surgery

    PubMed Central

    Parekattil, Sijo J; Gudeloglu, Ahmet

    2013-01-01

    The introduction of the operative microscope for andrological surgery in the 1970s provided enhanced magnification and accuracy, unparalleled to any previous visual loop or magnification techniques. This technology revolutionized techniques for microsurgery in andrology. Today, we may be on the verge of a second such revolution by the incorporation of robotic assisted platforms for microsurgery in andrology. Robotic assisted microsurgery is being utilized to a greater degree in andrology and a number of other microsurgical fields, such as ophthalmology, hand surgery, plastics and reconstructive surgery. The potential advantages of robotic assisted platforms include elimination of tremor, improved stability, surgeon ergonomics, scalability of motion, multi-input visual interphases with up to three simultaneous visual views, enhanced magnification, and the ability to manipulate three surgical instruments and cameras simultaneously. This review paper begins with the historical development of robotic microsurgery. It then provides an in-depth presentation of the technique and outcomes of common robotic microsurgical andrological procedures, such as vasectomy reversal, subinguinal varicocelectomy, targeted spermatic cord denervation (for chronic orchialgia) and robotic assisted microsurgical testicular sperm extraction (microTESE). PMID:23241637

  11. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    PubMed

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Hand gesture guided robot-assisted surgery based on a direct augmented reality interface.

    PubMed

    Wen, Rong; Tay, Wei-Liang; Nguyen, Binh P; Chng, Chin-Boon; Chui, Chee-Kong

    2014-09-01

    Radiofrequency (RF) ablation is a good alternative to hepatic resection for treatment of liver tumors. However, accurate needle insertion requires precise hand-eye coordination and is also affected by the difficulty of RF needle navigation. This paper proposes a cooperative surgical robot system, guided by hand gestures and supported by an augmented reality (AR)-based surgical field, for robot-assisted percutaneous treatment. It establishes a robot-assisted natural AR guidance mechanism that incorporates the advantages of the following three aspects: AR visual guidance information, surgeon's experiences and accuracy of robotic surgery. A projector-based AR environment is directly overlaid on a patient to display preoperative and intraoperative information, while a mobile surgical robot system implements specified RF needle insertion plans. Natural hand gestures are used as an intuitive and robust method to interact with both the AR system and surgical robot. The proposed system was evaluated on a mannequin model. Experimental results demonstrated that hand gesture guidance was able to effectively guide the surgical robot, and the robot-assisted implementation was found to improve the accuracy of needle insertion. This human-robot cooperative mechanism is a promising approach for precise transcutaneous ablation therapy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. EEG Analysis During Active and Assisted Repetitive Movements: Evidence for Differences in Neural Engagement.

    PubMed

    Tacchino, Giulia; Gandolla, Marta; Coelli, Stefania; Barbieri, Riccardo; Pedrocchi, Alessandra; Bianchi, Anna M

    2017-06-01

    Two key ingredients of a successful neuro-rehabilitative intervention have been identified as intensive and repetitive training and subject's active participation, which can be coupled in an active robot-assisted training. To exploit these two elements, we recorded electroencephalography, electromyography and kinematics signals from nine healthy subjects performing a 2×2 factorial design protocol, with subject's volitional intention and robotic glove assistance as factors. We quantitatively evaluated primary sensorimotor, premotor and supplementary motor areas activation during movement execution by computing event-related desynchronization (ERD) patterns associated to mu and beta rhythms. ERD patterns showed a similar behavior for all investigated regions: statistically significant ERDs began earlier in conditions requiring subject's volitional contribution; ERDs were prolonged towards the end of movement in conditions in which the robotic assistance was present. Our study suggests that the combination between subject volitional contribution and movement assistance provided by the robotic device (i.e., active robot-assisted modality) is able to provide early brain activation (i.e., earlier ERD) associated with stronger proprioceptive feedback (i.e., longer ERD). This finding might be particularly important for neurological patients, where movement cannot be completed autonomously and passive/active robot-assisted modalities are the only possibilities of execution.

  14. The immediate effects of robot-assistance on energy consumption and cardiorespiratory load during walking compared to walking without robot-assistance: a systematic review.

    PubMed

    Lefeber, Nina; Swinnen, Eva; Kerckhofs, Eric

    2017-10-01

    The integration of sufficient cardiovascular stress into robot-assisted gait (RAG) training could combine the benefits of both RAG and aerobic training. The aim was to summarize literature data on the immediate effects of RAG compared to walking without robot-assistance on metabolic-, cardiorespiratory- and fatigue-related parameters. PubMed and Web of Science were searched for eligible articles till February 2016. Means, SDs and significance values were extracted. Effect sizes were calculated. Fourteen studies were included, concerning 155 participants (85 healthy subjects, 39 stroke and 31 spinal cord injury patients), 9 robots (2 end-effectors, 1 treadmill-based and 6 wearable exoskeletons), and 7 outcome parameters (mostly oxygen consumption and heart rate). Overall, metabolic and cardiorespiratory parameters were lower during RAG compared to walking without robot-assistance (moderate to large effect sizes). In healthy subjects, when no body-weight support (BWS) was provided, RAG with an end-effector device was more energy demanding than walking overground (p > .05, large effect sizes). Generally, results suggest that RAG is less energy-consuming and cardiorespiratory stressful than walking without robot-assistance, but results depend on factors such as robot type, walking speed, BWS and effort. Additional research is needed to draw firm conclusions. Implications for Rehabilitation Awareness of the energy consumption and cardiorespiratory load of robot-assisted gait (RAG) training is important in the rehabilitation of (neurological) patients with impaired cardiorespiratory fitness and patients who are at risk of cardiovascular diseases. On the other hand, the integration of sufficient cardiometabolic stress in RAG training could combine the effects of both RAG and aerobic training. Energy consumption and cardiorespiratory load during walking with robot-assistance seems to depend on factors such as robot type, walking speed, body-weight support or amount of effort. These parameters could be adjusted in RAG rehabilitation to make RAG more or less energy-consuming and cardiorespiratory stressful. Overall, short duration exoskeleton walking seems less energy-consuming and cardiorespiratory stressful than walking without robot-assistance. This might implicate that the exercise intensity is safe for (neurological) patients at risk of cardiovascular diseases. How this changes in extended walking time is unclear.

  15. An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot.

    PubMed

    Kiguchi, K; Hayashi, Y

    2012-08-01

    Many kinds of power-assist robots have been developed in order to assist self-rehabilitation and/or daily life motions of physically weak persons. Several kinds of control methods have been proposed to control the power-assist robots according to user's motion intention. In this paper, an electromyogram (EMG)-based impedance control method for an upper-limb power-assist exoskeleton robot is proposed to control the robot in accordance with the user's motion intention. The proposed method is simple, easy to design, humanlike, and adaptable to any user. A neurofuzzy matrix modifier is applied to make the controller adaptable to any users. Not only the characteristics of EMG signals but also the characteristics of human body are taken into account in the proposed method. The effectiveness of the proposed method was evaluated by the experiments.

  16. A mobile robot therapist for under-supervised training with robot/computer assisted motivating systems.

    PubMed

    Shakya, Yuniya; Johnson, Michelle J

    2008-01-01

    Robot assisted therapy is a new and promising area in stroke rehabilitation and has shown to be effective in reducing motor impairment, but is a costly solution for home rehabilitation. High medical costs could be reduced if we could improve rehabilitation exercise in unsupervised environments such as the home. Hence, there is an augmented need for a cost effective rehabilitation system that can be used outside the clinic. This paper presents the design concept for an autonomous robotic assistant that is low-cost and effective in engaging the users while assisting them with therapy in any under-supervised area. We investigated how the robot assistant can support TheraDrive, our low-cost therapy system. We present the design methods and a case study demonstrating the arm and video collection system.

  17. The role of robotic surgical system in the management of vascular disease.

    PubMed

    Lin, Judith C

    2013-10-01

    The evolution of minimally invasive treatment for aneurysms and occlusive disease has led to the development of endovascular, laparoscopic, and robot-assisted techniques. This article reviews the current literature on the clinical use of robotic surgical systems in the treatment of patients with aneurysms and occlusive disease. A MEDLINE search was performed using the keywords "robotic, vascular, AND surgery." All pertinent articles concerning the use of the robotic surgical system on aneurysms and occlusive disease were reviewed. The author's personal experience consisted of a retrospective review of a prospectively maintained confidential database on all procedures performed with the da Vinci(®) surgical system. Several robot-assisted laparoscopic series on the treatment of aortic disease were identified, including review articles of potential clinical applications in hybrid, laparoscopic vascular, and endovascular treatments for vascular patients using robotic technology. The use of computer-enhanced or robotic technology as a sole modality for bypass of occlusive disease and repair of abdominal aortic, splenic, and renal aneurysms was described in case series with satisfactory patient outcomes. Current robotic endovascular technology was also described. Minimally invasive techniques using endovascular, laparoscopic, or robot-assisted technology have revolutionized the treatment of aortoiliac, splanchnic, and renal aneurysms and occlusive disease. However, robot-assisted techniques for aortic disease may involve a learning curve and increased operating times. Although endovascular therapy is preferred because of faster recovery, this preference for improved short-term outcomes will be balanced with the superiority and durability of robot-assisted endoscopic methods as comparable to open surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Reducing Operating Room Costs Through Real-Time Cost Information Feedback: A Pilot Study.

    PubMed

    Tabib, Christian H; Bahler, Clinton D; Hardacker, Thomas J; Ball, Kevin M; Sundaram, Chandru P

    2015-08-01

    To create a protocol for providing real-time operating room (OR) cost feedback to surgeons. We hypothesize that this protocol will reduce costs in a responsible way without sacrificing quality of care. All OR costs were obtained and recorded for robot-assisted partial nephrectomy and laparoscopic donor nephrectomy. Before the beginning of this project, costs pertaining to the 20 most recent cases were analyzed. Items were identified from previous cases as modifiable for replacement or omission. Timely feedback of total OR costs and cost of each item used was provided to the surgeon after each case, and costs were analyzed. A cost analysis of the robot-assisted partial nephrectomy before the washout period indicates expenditures of $5243.04 per case. Ten recommended modifiable items were found to have an average per case cost of $1229.33 representing 23.4% of the total cost. A postwashout period cost analysis found the total OR cost decreased by $899.67 (17.2%) because of changes directly related to the modifiable items. Therefore, 73.2% of the possible identified savings was realized. The same stepwise approach was applied to laparoscopic donor nephrectomies. The average total cost per case before the washout period was $3530.05 with $457.54 attributed to modifiable items. After the washout period, modifiable items costs were reduced by $289.73 (8.0%). No complications occurred in the donor nephrectomy cases while one postoperative complication occurred in the partial nephrectomy group. Providing surgeons with feedback related to OR costs may lead to a change in surgeon behavior and decreased overall costs. Further studies are needed to show equivalence in patient outcomes.

  19. Robot-assisted Versus Laparoscopic Surgery for Rectal Cancer: A Phase II Open Label Prospective Randomized Controlled Trial.

    PubMed

    Kim, Min Jung; Park, Sung Chan; Park, Ji Won; Chang, Hee Jin; Kim, Dae Yong; Nam, Byung-Ho; Sohn, Dae Kyung; Oh, Jae Hwan

    2018-02-01

    The phase II randomized controlled trial aimed to compare the outcomes of robot-assisted surgery with those of laparoscopic surgery in the patients with rectal cancer. The feasibility of robot-assisted surgery over laparoscopic surgery for rectal cancer has not been established yet. Between February 21, 2012 and March 11, 2015, patients with rectal cancer (cT1-3NxM0) were enrolled. Patients were randomized 1:1 to either robot-assisted or laparoscopic surgery, and stratified per sex and administration of preoperative chemoradiotherapy. The primary outcome was the quality of total mesorectal excision (TME) specimen. Secondary outcomes were the circumferential and distal resection margins, the number of harvested lymph nodes, morbidity, bowel function recovery, and quality of life. A total of 163 patients were randomly assigned to the robot-assisted (n = 81) and laparoscopic (n = 82) surgery groups, and 139 patients were eligible for the analyses (73 vs 66, respectively). One patient (1.2%) in the robot-assisted group was converted to open surgery. The TME quality did not differ between the robot-assisted and laparoscopic groups (80.3% vs 78.1% complete TME, respectively; 18.2% vs 21.9% nearly complete TME, respectively; P = 0.599). The resection margins, number of harvested lymph nodes, morbidity, and bowel function recovery also were not significantly different. On analyzing quality of life, scores of the European Organization for Research and Treatment of Cancer Quality of Life (EORTC QLQ C30) and EORTC QLQ CR38 were similar in the 2 groups, but in the EORTC QLQ CR 38 questionnaire, sexual function 12 months postoperatively was better in the robot-assisted group than in the laparoscopic group (P = 0.03). Robot-assisted surgery in rectal cancer showed TME quality comparable with that of laparoscopic surgery, and it demonstrated similar postoperative morbidity, bowel function recovery, and quality of life.

  20. Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population.

    PubMed

    Macke, Jeremy J; Woo, Raymund; Varich, Laura

    2016-06-01

    This is a retrospective review of pedicle screw placement in adolescent idiopathic scoliosis (AIS) patients under 18 years of age who underwent robot-assisted corrective surgery. Our primary objective was to characterize the accuracy of pedicle screw placement with evaluation by computed tomography (CT) after robot-assisted surgery in AIS patients. Screw malposition is the most frequent complication of pedicle screw placement and is more frequent in AIS. Given the potential for serious complications, the need for improved accuracy of screw placement has spurred multiple innovations including robot-assisted guidance devices. No studies to date have evaluated this robot-assisted technique using CT exclusively within the AIS population. Fifty patients were included in the study. All operative procedures were performed at a single institution by a single pediatric orthopedic surgeon. We evaluated the grade of screw breach, the direction of screw breach, and the positioning of the patient for preoperative scan (supine versus prone). Of 662 screws evaluated, 48 screws (7.2 %) demonstrated a breach of greater than 2 mm. With preoperative prone position CT scanning, only 2.4 % of screws were found to have this degree of breach. Medial malposition was found in 3 % of screws, a rate which decreased to 0 % with preoperative prone position scanning. Based on our results, we conclude that the proper use of image-guided robot-assisted surgery can improve the accuracy and safety of thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis. This is the first study to evaluate the accuracy of pedicle screw placement using CT assessment in robot-assisted surgical correction of patients with AIS. In our study, the robot-assisted screw misplacement rate was lower than similarly constructed studies evaluating conventional (non-robot-assisted) procedures. If patients are preoperatively scanned in the prone position, the misplacement rate is further decreased.

  1. Robot-assisted laparoscopic intracorporeal hand-sewn bowel anastomosis during pediatric bladder reconstructive surgery.

    PubMed

    Gundeti, Mohan S; Wiltz, Aimee L; Zagaja, Gregory P; Shalhav, Arieh L

    2010-08-01

    Bowel anastomosis performed during robot-assisted laparoscopic surgery in both adult and pediatric populations has typically been performed using endoscopic staplers or with exteriorization of the bowel. In the pediatric population, no articles have been published that explore the possibility of a completely intracorporeal hand-sewn anastomosis during robot-assisted laparoscopic surgery. We report our series of six children who were undergoing robot-assisted laparoscopic intracorporeal hand-sewn bowel anastomosis during bladder reconstructive surgery for neurogenic bladder. The postoperative course was uncomplicated with regard to the bowel anastomosis, demonstrating the feasibility of the technique in experienced hands.

  2. Comparison of two techniques of robot-aided upper limb exercise training after stroke.

    PubMed

    Stein, Joel; Krebs, Hermano Igo; Frontera, Walter R; Fasoli, Susan E; Hughes, Richard; Hogan, Neville

    2004-09-01

    This study examined whether incorporating progressive resistive training into robot-aided exercise training provides incremental benefits over active-assisted robot-aided exercise for the upper limb after stroke. A total of 47 individuals at least 1 yr poststroke were enrolled in this 6-wk training protocol. Paretic upper limb motor abilities were evaluated using clinical measures and a robot-based assessment to determine eligibility for robot-aided progressive resistive training at study entry. Subjects capable of participating in resistance training were randomized to receive either active-assisted robot-aided exercises or robot-aided progressive resistance training. Subjects who were incapable of participating in resistance training underwent active-assisted robotic therapy and were again screened for eligibility after 3 wks of robotic therapy. Those subjects capable of participating in resistance training at 3 wks were then randomized to receive either robot-aided resistance training or to continue with robot-aided active-assisted training. One subject withdrew due to unrelated medical issues, and data for the remaining 46 subjects were analyzed. Subjects in all groups showed improvement in measures of motor control (mean increase in Fugl-Meyer of 3.3; 95% confidence interval, 2.2-4.4) and maximal force (mean increase in maximal force of 3.5 N, P = 0.027) over the course of robot-aided exercise training. No differences in outcome measures were observed between the resistance training groups and the matched active-assisted training groups. Subjects' ability to perform the robotic task at the time of group assignment predicted the magnitude of the gain in motor control. The incorporation of robot-aided progressive resistance exercises into a program of robot-aided exercise did not favorably or negatively affect the gains in motor control or strength associated with this training, though interpretation of these results is limited by sample size. Individuals with better motor control at baseline experienced greater increases in motor control with robotic training.

  3. Technical features of the robot-assisted trans-axillary thyroidectomy.

    PubMed

    Axente, D D; Major, Z Z; Micu, C M; Constantea, N A

    2013-01-01

    Numerous minimally invasive techniques for thyroid surgery have been described in recent years. Technical disadvantages have led to low practicability, although these techniques proved to be safe and to deliver good results. The robotic system was developed to overcome the limits of endoscopic surgery.Recently, based on the advantages of this new technology, robot assisted endoscopic surgery was introduced for minimally invasive thyroid surgery as well. Our experience with robot-assisted transaxillary thyroid surgery begins in November 2010 when we have practiced our first unilateral total lobectomy. From November 2010 to March 2012, 50 patients underwent robot assisted endoscopic thyroid surgery using the transaxillary approach. The aim of this study is to present the technical details and particularities of this procedure, based on our experience.

  4. Robot-assisted surgery in gynecological oncology: current status and controversies on patient benefits, cost and surgeon conditions - a systematic review.

    PubMed

    Kristensen, Steffen E; Mosgaard, Berit J; Rosendahl, Mikkel; Dalsgaard, Tórur; Bjørn, Signe F; Frøding, Ligita P; Kehlet, Henrik; Høgdall, Claus K; Lajer, Henrik

    2017-03-01

    Robot-assisted surgery has become more widespread in gynecological oncology. The purpose of this systematic review is to present current knowledge on robot-assisted surgery, and to clarify and discuss controversies that have arisen alongside the development and deployment. A database search in PubMed and EMBASE was performed up until 4 March 2016. The search strategy was developed in collaboration with an information specialist, and by application of the PRISMA guidelines. Human participants and English language were the only restrictive filters applied. Selection was performed by screening of titles and abstracts, and by full text scrutiny. From 2001 to 2016, a total of 76 references were included. Robot-assisted surgery in gynecological oncology has increased, and current knowledge supports that the oncological safety is similar, compared with previous surgical methods. Controversies arise because current knowledge does not clearly document the benefit of robot-assisted surgery, on perioperative outcome compared with the increased costs of the acquisition and application. The rapid development in robot-assisted surgery calls for long-term detailed prospective cohorts or randomized controlled trials. The costs associated with acquisition, application, and maintenance have an unfavorable impact on cost-benefit evaluations, especially when compared with laparoscopy. Future developments in robot-assisted surgery will hopefully lead to competition in the market, which will decrease costs. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  5. Overactive bladder is a negative predictor of achieving continence after robot-assisted radical prostatectomy.

    PubMed

    Yamada, Yuta; Fujimura, Tetsuya; Fukuhara, Hiroshi; Sugihara, Toru; Miyazaki, Hideyo; Nakagawa, Tohru; Kume, Haruki; Igawa, Yasuhiko; Homma, Yukio

    2017-10-01

    To investigate predictors of continence outcomes after robot-assisted radical prostatectomy. Clinical records of 272 patients who underwent robot-assisted radical prostatectomy were investigated. Preoperative Overactive Bladder Symptom Score, International Prostate Symptom Score and clinicopathological factors were investigated, and relationships between factors and recovery of continence after robot-assisted radical prostatectomy were assessed. The presence of overactive bladder was defined as having urgency for more than once a week and having ≥3 points according to the Overactive Bladder Symptom Score. Age (≤66 years) was significantly associated with continence within 6 months after robot-assisted radical prostatectomy (P = 0.033). The absence of overactive bladder and lower Overactive Bladder Symptom Score (<3) were significantly associated with recovery of continence within 12 months after surgery (both variables P = 0.009). In terms of achieving recovery of continence after robot-assisted radical prostatectomy, Kaplan-Meier curves showed earlier recovery in "age ≤66 years," "prostate weight ≤40 g" and "overactive bladder symptom score <3" (P = 0.0072, 0.0172 and 0.0140, respectively). Multivariate analysis showed that the presence of overactive bladder was an independent negative predictor for recovery of continence within 12 months after surgery (P = 0.019). The presence of baseline overactive bladder seems to represent an independent negative predictor for recovery of continence at 12 months after robot-assisted radical prostatectomy. © 2017 The Japanese Urological Association.

  6. Combined functional electrical stimulation (FES) and robotic system for wrist rehabiliation after stroke.

    PubMed

    Hu, Xiaoling; Tong, K Y; Li, R; Chen, M; Xue, J J; Ho, S K; Chen, P N

    2010-01-01

    Functional electrical stimulation (FES) and rehabilitation robots are techniques used to assist in post-stroke rehabilitation. However, FES and rehabilitation robots are still separate systems currently; and their combined training effects on persons after experiencing a stroke have not been well studied yet. In this work, a new combined FES-robot system driven by user's voluntary intention was developed for wrist joint training after stroke. The performance of the FES-robot assisted wrist tracking was evaluated on five subjects with chronic stroke. With simultaneous assistance from both the FES and robot parts of the system, the motion accuracy was improved and excessive activation in elbow flexor was reduced during wrist tracking.

  7. Multispectral Fluorescence Imaging During Robot-assisted Laparoscopic Sentinel Node Biopsy: A First Step Towards a Fluorescence-based Anatomic Roadmap.

    PubMed

    van den Berg, Nynke S; Buckle, Tessa; KleinJan, Gijs H; van der Poel, Henk G; van Leeuwen, Fijs W B

    2017-07-01

    During (robot-assisted) sentinel node (SN) biopsy procedures, intraoperative fluorescence imaging can be used to enhance radioguided SN excision. For this combined pre- and intraoperative SN identification was realized using the hybrid SN tracer, indocyanine green- 99m Tc-nanocolloid. Combining this dedicated SN tracer with a lymphangiographic tracer such as fluorescein may further enhance the accuracy of SN biopsy. Clinical evaluation of a multispectral fluorescence guided surgery approach using the dedicated SN tracer ICG- 99m Tc-nanocolloid, the lymphangiographic tracer fluorescein, and a commercially available fluorescence laparoscope. Pilot study in ten patients with prostate cancer. Following ICG- 99m Tc-nanocolloid administration and preoperative lymphoscintigraphy and single-photon emission computed tomograpy imaging, the number and location of SNs were determined. Fluorescein was injected intraprostatically immediately after the patient was anesthetized. A multispectral fluorescence laparoscope was used intraoperatively to identify both fluorescent signatures. Multispectral fluorescence imaging during robot-assisted radical prostatectomy with extended pelvic lymph node dissection and SN biopsy. (1) Number and location of preoperatively identified SNs. (2) Number and location of SNs intraoperatively identified via ICG- 99m Tc-nanocolloid imaging. (3) Rate of intraoperative lymphatic duct identification via fluorescein imaging. (4) Tumor status of excised (sentinel) lymph node(s). (5) Postoperative complications and follow-up. Near-infrared fluorescence imaging of ICG- 99m Tc-nanocolloid visualized 85.3% of the SNs. In 8/10 patients, fluorescein imaging allowed bright and accurate identification of lymphatic ducts, although higher background staining and tracer washout were observed. The main limitation is the small patient population. Our findings indicate that a lymphangiographic tracer can provide additional information during SN biopsy based on ICG- 99m Tc-nanocolloid. The study suggests that multispectral fluorescence image-guided surgery is clinically feasible. We evaluated the concept of surgical fluorescence guidance using differently colored dyes that visualize complementary features. In the future this concept may provide better guidance towards diseased tissue while sparing healthy tissue, and could thus improve functional and oncologic outcomes. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  8. Inducing self-selected human engagement in robotic locomotion training.

    PubMed

    Collins, Steven H; Jackson, Rachel W

    2013-06-01

    Stroke leads to severe mobility impairments for millions of individuals each year. Functional outcomes can be improved through manual treadmill therapy, but high costs limit patient exposure and, thereby, outcomes. Robotic gait training could increase the viable duration and frequency of training sessions, but robotic approaches employed thus far have been less effective than manual therapy. These shortcomings may relate to subconscious energy-minimizing drives, which might cause patients to engage less actively in therapy when provided with corrective robotic assistance. We have devised a new method for gait rehabilitation that harnesses, rather than fights, least-effort tendencies. Therapeutic goals, such as increased use of the paretic limb, are made easier than the patient's nominal gait through selective assistance from a robotic platform. We performed a pilot test on a healthy subject (N = 1) in which altered self-selected stride length was induced using a tethered robotic ankle-foot orthosis. The subject first walked on a treadmill while wearing the orthosis with and without assistance at unaltered and voluntarily altered stride length. Voluntarily increasing stride length by 5% increased metabolic energy cost by 4%. Robotic assistance decreased energy cost at both unaltered and voluntarily increased stride lengths, by 6% and 8% respectively. We then performed a test in which the robotic system continually monitored stride length and provided more assistance if the subject's stride length approached a target increase. This adaptive assistance protocol caused the subject to slowly adjust their gait patterns towards the target, leading to a 4% increase in stride length. Metabolic energy consumption was simultaneously reduced by 5%. These results suggest that selective-assistance protocols based on targets relevant to rehabilitation might lead patients to self-select desirable gait patterns during robotic gait training sessions, possibly facilitating better adherence and outcomes.

  9. Effectiveness of robot-assisted therapy on ankle rehabilitation--a systematic review.

    PubMed

    Zhang, Mingming; Davies, T Claire; Xie, Shane

    2013-03-21

    The aim of this study was to provide a systematic review of studies that investigated the effectiveness of robot-assisted therapy on ankle motor and function recovery from musculoskeletal or neurologic ankle injuries. Thirteen electronic databases of articles published from January, 1980 to June, 2012 were searched using keywords 'ankle*', 'robot*', 'rehabilitat*' or 'treat*' and a free search in Google Scholar based on effects of ankle rehabilitation robots was also conducted. References listed in relevant publications were further screened. Eventually, twenty-nine articles were selected for review and they focused on effects of robot-assisted ankle rehabilitation. Twenty-nine studies met the inclusion criteria and a total of 164 patients and 24 healthy subjects participated in these trials. Ankle performance and gait function were the main outcome measures used to assess the therapeutic effects of robot-assisted ankle rehabilitation. The protocols and therapy treatments were varied, which made comparison among different studies difficult or impossible. Few comparative trials were conducted among different devices or control strategies. Moreover, the majority of study designs met levels of evidence that were no higher than American Academy for Cerebral Palsy (CP) and Developmental Medicine (AACPDM) level IV. Only one study used a Randomized Control Trial (RCT) approach with the evidence level being II. All the selected studies showed improvements in terms of ankle performance or gait function after a period of robot-assisted ankle rehabilitation training. The most effective robot-assisted intervention cannot be determined due to the lack of universal evaluation criteria for various devices and control strategies. Future research into the effects of robot-assisted ankle rehabilitation should be carried out based on universal evaluation criteria, which could determine the most effective method of intervention. It is also essential to conduct trials to analyse the differences among different devices or control strategies.

  10. Effects of electromyography-driven robot-aided hand training with neuromuscular electrical stimulation on hand control performance after chronic stroke.

    PubMed

    Rong, Wei; Tong, Kai Yu; Hu, Xiao Ling; Ho, Sze Kit

    2015-03-01

    An electromyography-driven robot system integrated with neuromuscular electrical stimulation (NMES) was developed to investigate its effectiveness on post-stroke rehabilitation. The performance of this system in assisting finger flexion/extension with different assistance combinations was evaluated in five stroke subjects. Then, a pilot study with 20-sessions training was conducted to evaluate the training's effectiveness. The results showed that combined assistance from the NMES-robot could improve finger movement accuracy, encourage muscle activation of the finger muscles and suppress excessive muscular activities in the elbow joint. When assistances from both NMES and the robot were 50% of their maximum assistances, finger-tracking performance had the best results, with the lowest root mean square error, greater range of motion, higher voluntary muscle activations of the finger joints and lower muscle co-contraction in the finger and elbow joints. Upper limb function improved after the 20-session training, indicated by the increased clinical scores of Fugl-Meyer Assessment, Action Research Arm Test and Wolf Motor Function Test. Muscle co-contraction was reduced in the finger and elbow joints reflected by the Modified Ashworth Scale. The findings demonstrated that an electromyography-driven NMES-robot used for chronic stroke improved hand function and tracking performance. Further research is warranted to validate the method on a larger scale. Implications for Rehabilitation The hand robotics and neuromuscular electrical stimulation (NMES) techniques are still separate systems in current post-stroke hand rehabilitation. This is the first study to investigate the combined effects of the NMES and robot on hand rehabilitation. The finger tracking performance was improved with the combined assistance from the EMG-driven NMES-robot hand system. The assistance from the robot could improve the finger movement accuracy and the assistance from the NMES could reduce the muscle co-contraction on finger and elbow joints. The upper limb functions were improved on chronic stroke patients after the pilot study of 20-session hand training with the combined assistance from the EMG-driven NMES-robot. The muscle spasticity on finger and elbow joints was reduced after the training.

  11. Robot-Assisted Medial Compartment Arthroplasty Following Remote Patellectomy: A Case Report

    PubMed Central

    Kouk, Shalen; Kalbian, Irene; Wolfe, Elizabeth; Strickland, Sabrina M

    2018-01-01

    Introduction: Total patellectomies are uncommon procedures that are reserved as salvage treatment for severely comminuted fractures of the patella. Due to the alteration of normal joint mechanics, these patients present later on in life with degenerative cartilage damage to the femorotibial joint and altered extensor mechanism. There are very few reports of unicondylar knee arthroplasties following previous patellectomy and none that specifically address robot-assisted unicompartmental knee arthroplasty. A recent case report by Pang et al. described the use of minimally invasive fixed-bearing unicondylar knee arthroplasty in a patellectomized patient with moderate medial compartment osteoarthritis. Our report details a case with more significant chondral loss along with patellar tendon subluxation. Case Report: This is a case report of a patient with severe medial compartment osteoarthritis after a patellectomy following a motor vehicle collision. After failing conservative treatment, the patient underwent a medial MAKOplasty with complete resolution of arthritic pain. Conclusion: Significant pain relief and improved knee function can be achieved with MAKOPlasty partial knee resurfacing system in a previously patellectomized patient with severe medial compartment osteoarthritis. PMID:29854684

  12. Application requirements for Robotic Nursing Assistants in hospital environments

    NASA Astrophysics Data System (ADS)

    Cremer, Sven; Doelling, Kris; Lundberg, Cody L.; McNair, Mike; Shin, Jeongsik; Popa, Dan

    2016-05-01

    In this paper we report on analysis toward identifying design requirements for an Adaptive Robotic Nursing Assistant (ARNA). Specifically, the paper focuses on application requirements for ARNA, envisioned as a mobile assistive robot that can navigate hospital environments to perform chores in roles such as patient sitter and patient walker. The role of a sitter is primarily related to patient observation from a distance, and fetching objects at the patient's request, while a walker provides physical assistance for ambulation and rehabilitation. The robot will be expected to not only understand nurse and patient intent but also close the decision loop by automating several routine tasks. As a result, the robot will be equipped with sensors such as distributed pressure sensitive skins, 3D range sensors, and so on. Modular sensor and actuator hardware configured in the form of several multi-degree-of-freedom manipulators, and a mobile base are expected to be deployed in reconfigurable platforms for physical assistance tasks. Furthermore, adaptive human-machine interfaces are expected to play a key role, as they directly impact the ability of robots to assist nurses in a dynamic and unstructured environment. This paper discusses required tasks for the ARNA robot, as well as sensors and software infrastructure to carry out those tasks in the aspects of technical resource availability, gaps, and needed experimental studies.

  13. An Intelligent Agent-Controlled and Robot-Based Disassembly Assistant

    NASA Astrophysics Data System (ADS)

    Jungbluth, Jan; Gerke, Wolfgang; Plapper, Peter

    2017-09-01

    One key for successful and fluent human-robot-collaboration in disassembly processes is equipping the robot system with higher autonomy and intelligence. In this paper, we present an informed software agent that controls the robot behavior to form an intelligent robot assistant for disassembly purposes. While the disassembly process first depends on the product structure, we inform the agent using a generic approach through product models. The product model is then transformed to a directed graph and used to build, share and define a coarse disassembly plan. To refine the workflow, we formulate “the problem of loosening a connection and the distribution of the work” as a search problem. The created detailed plan consists of a sequence of actions that are used to call, parametrize and execute robot programs for the fulfillment of the assistance. The aim of this research is to equip robot systems with knowledge and skills to allow them to be autonomous in the performance of their assistance to finally improve the ergonomics of disassembly workstations.

  14. Will Robots Ever Replace Attendants? Exploring the Current Capabilities and Future Potential of Robots in Education and Rehabilitation.

    ERIC Educational Resources Information Center

    Lees, David; LePage, Pamela

    1994-01-01

    This article describes the current capabilities and future potential of robots designed as supplements or replacements for human assistants or as tools for education and rehabilitation of people with disabilities. Review of robots providing educational, vocational, or independent living assistance concludes that eventually effective, reliable…

  15. Robotic Teaching Assistance for the "Tower of Hanoi" Problem

    ERIC Educational Resources Information Center

    Thien, Nguyen Duc; Terracina, Annalisa; Iocchi, Luca; Mecella, Massimo

    2016-01-01

    In this work the authors investigate the effectiveness of robotics in education. Rather than creating excitement for children when playing with robots in games, they are examining the overall learning environment where a robot acts as a teaching assistant. They designed a suitable lesson plan when groups of teenagers participate in activities…

  16. Analysis of reaching movements of upper arm in robot assisted exercises. Kinematic assessment of robot assisted upper arm reaching single-joint movements.

    PubMed

    Iuppariello, Luigi; D'Addio, Giovanni; Romano, Maria; Bifulco, Paolo; Lanzillo, Bernardo; Pappone, Nicola; Cesarelli, Mario

    2016-01-01

    Robot-mediated therapy (RMT) has been a very dynamic area of research in recent years. Robotics devices are in fact capable to quantify the performances of a rehabilitation task in treatments of several disorders of the arm and the shoulder of various central and peripheral etiology. Different systems for robot-aided neuro-rehabilitation are available for upper limb rehabilitation but the biomechanical parameters proposed until today, to evaluate the quality of the movement, are related to the specific robot used and to the type of exercise performed. Besides, none study indicated a standardized quantitative evaluation of robot assisted upper arm reaching movements, so the RMT is still far to be considered a standardised tool. In this paper a quantitative kinematic assessment of robot assisted upper arm reaching movements, considering also the effect of gravity on the quality of the movements, is proposed. We studied a group of 10 healthy subjects and results indicate that our advised protocol can be useful for characterising normal pattern in reaching movements.

  17. 76 FR 67716 - Notice of Intent To Grant Partially Exclusive Patent License; ReconRobotics, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-02

    ... DEPARTMENT OF DEFENSE Department of the Navy Notice of Intent To Grant Partially Exclusive Patent License; ReconRobotics, Inc. AGENCY: Department of the Navy, DoD. ACTION: Notice. SUMMARY: The Department of the Navy hereby gives notice of its intent to grant to ReconRobotics, Inc., a revocable...

  18. Incorporating robotic-assisted surgery for endometrial cancer staging: Analysis of morbidity and costs.

    PubMed

    Bogani, Giorgio; Multinu, Francesco; Dowdy, Sean C; Cliby, William A; Wilson, Timothy O; Gostout, Bobbie S; Weaver, Amy L; Borah, Bijan J; Killian, Jill M; Bijlani, Akash; Angioni, Stefano; Mariani, Andrea

    2016-05-01

    To evaluate how the introduction of robotic-assisted surgery affects treatment-related morbidity and cost of endometrial cancer (EC) staging. We retrospectively reviewed the records of consecutive patients with stage I-III EC undergoing surgical staging between 2007 and 2012 at our institution. Costs (from surgery to 30days after surgery) were set based on the Medicare cost-to-charge ratio for each year and inflated to 2014 values. Inverse probability weighting (IPW) was used to decrease the allocation bias when comparing outcomes between surgical groups. We focused our analysis on the 251 EC patients who had robotic-assisted surgery and the 384 who had open staging. During the study period, the use of robotic-assisted surgery increased and open staging decreased (P<0.001). Correcting group imbalances by using IPW methodology, we observed that patients undergoing robotic-assisted staging had a significantly lower postoperative complication rate, lower blood transfusion rate, longer median operating time, shorter median length of stay, and lower readmission rate than patients undergoing open staging (all P<0.001). Overall 30-day costs were similar between the 2 groups, with robotic-assisted surgery having significantly higher median operating room costs ($2820 difference; P<0.001) but lower median room and board costs ($2929 difference; P<0.001) than open surgery. Increasing experience with robotic-assisted staging was significantly associated with a decrease in median operating time (P=0.002) and length of stay (P=0.003). The implementation of robotic-assisted surgery for EC staging improves patient outcomes. It provides women the benefits of minimally invasive surgery without increasing costs and potentially improves patient turnover. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. A Lower Limb Rehabilitation Robot in Sitting Position with a Review of Training Activities.

    PubMed

    Eiammanussakul, Trinnachoke; Sangveraphunsiri, Viboon

    2018-01-01

    Robots for stroke rehabilitation at the lower limbs in sitting/lying position have been developed extensively. Some of them have been applied in clinics and shown the potential of the recovery of poststroke patients who suffer from hemiparesis. These robots were developed to provide training at different joints of lower limbs with various activities and modalities. This article reviews the training activities that were realized by rehabilitation robots in literature, in order to offer insights for developing a novel robot suitable for stroke rehabilitation. The control system of the lower limb rehabilitation robot in sitting position that was introduced in the previous work is discussed in detail to demonstrate the behavior of the robot while training a subject. The nonlinear impedance control law, based on active assistive control strategy, is able to define the response of the robot with more specifications while the passivity property and the robustness of the system is verified. A preliminary experiment is conducted on a healthy subject to show that the robot is able to perform active assistive exercises with various training activities and assist the subject to complete the training with desired level of assistance.

  20. Perioperative surgical outcome of conventional and robot-assisted total laparoscopic hysterectomy.

    PubMed

    van Weelden, W J; Gordon, B B M; Roovers, E A; Kraayenbrink, A A; Aalders, C I M; Hartog, F; Dijkhuizen, F P H L J

    2017-01-01

    To evaluate surgical outcome in a consecutive series of patients with conventional and robot assisted total laparoscopic hysterectomy. A retrospective cohort study was performed among patients with benign and malignant indications for a laparoscopic hysterectomy. Main surgical outcomes were operation room time and skin to skin operating time, complications, conversions, rehospitalisation and reoperation, estimated blood loss and length of hospital stay. A total of 294 patients were evaluated: 123 in the conventional total laparoscopic hysterectomy (TLH) group and 171 in the robot TLH group. After correction for differences in basic demographics with a multivariate linear regression analysis, the skin to skin operating time was a significant 18 minutes shorter in robot assisted TLH compared to conventional TLH (robot assisted TLH 92m, conventional TLH 110m, p0.001). The presence or absence of previous abdominal surgery had a significant influence on the skin to skin operating time as did the body mass index and the weight of the uterus. Complications were not significantly different. The robot TLH group had significantly less blood loss and lower rehospitalisation and reoperation rates. This study compares conventional TLH with robot assisted TLH and shows shorter operating times, less blood loss and lower rehospitalisation and reoperation rates in the robot TLH group.

  1. Robotic-assisted vesicovaginal fistula repair using an extravesical approach without interposition grafting.

    PubMed

    Kelly, Erin; Wu, Maria Y; MacMillan, J Barry

    2018-03-01

    Post-hysterectomy vesicovaginal fistula (VVF) is rare. In addition to conventional abdominal and vaginal approaches, robotic-assisted VVF repairs have recently been described. We present a case of an extravesical, robotic-assisted VVF repair, without placement of an interposition graft performed in a Canadian teaching center. A 51-year-old woman presented with urinary incontinence 5 days after laparoscopic hysterectomy. Computed tomography cystogram, cystoscopy, and methylene blue dye test, confirmed a VVF above the bladder trigone. The patient underwent a robotic-assisted VVF repair 3 months after presentation, without complication. An abdominal, extravesical approach was used. Operative time was 116 min and repeat CT cystogram showed no evidence of persistent. We have demonstrated that a VVF repair, using a robotic-assisted, extravesical approach without interposition graft placement, can be safe, less invasive and have a successful outcome at 1 year of follow-up.

  2. Turning assistive machines into assistive robots

    NASA Astrophysics Data System (ADS)

    Argall, Brenna D.

    2015-01-01

    For decades, the potential for automation in particular, in the form of smart wheelchairs to aid those with motor, or cognitive, impairments has been recognized. It is a paradox that often the more severe a person's motor impairment, the more challenging it is for them to operate the very assistive machines which might enhance their quality of life. A primary aim of my lab is to address this confound by incorporating robotics autonomy and intelligence into assistive machines turning the machine into a kind of robot, and offloading some of the control burden from the user. Robots already synthetically sense, act in and reason about the world, and these technologies can be leveraged to help bridge the gap left by sensory, motor or cognitive impairments in the users of assistive machines. This paper overviews some of the ongoing projects in my lab, which strives to advance human ability through robotics autonomy.

  3. Social skills training for children with autism spectrum disorder using a robotic behavioral intervention system.

    PubMed

    Yun, Sang-Seok; Choi, JongSuk; Park, Sung-Kee; Bong, Gui-Young; Yoo, HeeJeong

    2017-07-01

    We designed a robot system that assisted in behavioral intervention programs of children with autism spectrum disorder (ASD). The eight-session intervention program was based on the discrete trial teaching protocol and focused on two basic social skills: eye contact and facial emotion recognition. The robotic interactions occurred in four modules: training element query, recognition of human activity, coping-mode selection, and follow-up action. Children with ASD who were between 4 and 7 years old and who had verbal IQ ≥ 60 were recruited and randomly assigned to the treatment group (TG, n = 8, 5.75 ± 0.89 years) or control group (CG, n = 7; 6.32 ± 1.23 years). The therapeutic robot facilitated the treatment intervention in the TG, and the human assistant facilitated the treatment intervention in the CG. The intervention procedures were identical in both groups. The primary outcome measures included parent-completed questionnaires, the Autism Diagnostic Observation Schedule (ADOS), and frequency of eye contact, which was measured with the partial interval recording method. After completing treatment, the eye contact percentages were significantly increased in both groups. For facial emotion recognition, the percentages of correct answers were increased in similar patterns in both groups compared to baseline (P > 0.05), with no difference between the TG and CG (P > 0.05). The subjects' ability to play, general behavioral and emotional symptoms were significantly diminished after treatment (p < 0.05). These results showed that the robot-facilitated and human-facilitated behavioral interventions had similar positive effects on eye contact and facial emotion recognition, which suggested that robots are useful mediators of social skills training for children with ASD. Autism Res 2017,. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. Autism Res 2017, 10: 1306-1323. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.

  4. Comparison of Two Endovascular Steerable Robotic Catheters for Percutaneous Robot-Assisted Fibroid Embolization.

    PubMed

    Del Giudice, C; Pellerin, O; Nouri Neville, M; Amouyal, G; Fitton, I; Leré-Déan, C; Sapoval, M

    2018-03-01

    To compare outcomes of percutaneous robot-assisted uterine fibroid embolization (UFE) using two different endovascular robotic catheters. Twenty-one patients with a symptomatic uterine fibroid were prospectively enrolled in a single-center study to be treated with a percutaneous robot-assisted embolization using the Magellan system. Fourteen patients were treated using a first generation steerable robotic catheter, version 1.0 (group 1), and seven were treated using the new version 1.1 (group 2). Demographic, pathologic, and procedural variables were recorded. Dose Area Product (DAP) and physician equivalent doses were registered for each procedure. Procedural related complications and clinical midterm outcomes were also evaluated. Successful robot-assisted UFE was obtained in eight patients (57.1%) in group 1 and 7 patients (100%) in group 2 (p = 0.01). A successful robot-assisted catheterization of the internal iliac artery anterior branch was performed in all patients of both groups. Median selective target vessel catheterization time was 21.0 ± 12.8 vs 13.4 ± 7 min (p = 0.04) and total fluoroscopy time was 30.3 ± 11.2 vs 19.3 ± 5.9 min, respectively, in group 1 and 2. Mean DAP decreased from 18472.6 ± 15622 to 5469.1 ± 4461.0 cGy·cm 2 (p = 0.04). All patients obtained a symptoms relief at 6 months follow-up. Robot-assisted uterine fibroid embolization is safe and effective. New version of steerable robotic catheter allows performing a faster procedure without related adverse events compared to old version.

  5. Robotic posterior retroperitoneal adrenalectomy.

    PubMed

    Okoh, Alexis Kofi; Yigitbas, Hakan; Berber, Eren

    2015-09-01

    Since its initial description by Mercan et al. laparoscopic posterior retroperitoneal (PR) adrenalectomy has served as an alternaltive to the transabdominal (TL) approach for the treatment of adrenal pathologies. Robotic adrenal surgery has been reported to improve surgeon ergonomics and facilitate dissection. In patients with bilateral adrenal masses, PR adrenalectomy may be the approach of choice. We herein describe the technique, discuss its limitations and present a critical review of the current literature. © 2015 Wiley Periodicals, Inc.

  6. Cost-effectiveness of robotic-assisted laparoscopic procedures in urologic surgery in the USA.

    PubMed

    Sleeper, Joshua; Lotan, Yair

    2011-01-01

    New technologies such as robotic-assisted surgery are constantly introduced clinically without a complete understanding of benefits and costs. This article will discuss general concepts of health economics and apply them to the application of robotic-assisted surgery to urologic procedures. Utilization of robotic surgery has increased dramatically in recent years. This has been most dramatic in the treatment of prostate cancer. The robot adds significant costs from acquisition, maintenance and recurrent instrument costs. These added costs, thus far, have not been associated with significant improvement in outcomes over 'pure' laparoscopy or open procedures. In order for the robot to be cost effective, there needs to be an improvement in efficacy over alternative approaches, and a decrease in costs of the robot or instrumentation. Robotic surgery has not been found to be cost effective in urology. Future studies may yet reveal indirect benefits that are not yet obvious.

  7. Knowledge assistant: A sensor fusion framework for robotic environmental characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feddema, J.T.; Rivera, J.J.; Tucker, S.D.

    1996-12-01

    A prototype sensor fusion framework called the {open_quotes}Knowledge Assistant{close_quotes} has been developed and tested on a gantry robot at Sandia National Laboratories. This Knowledge Assistant guides the robot operator during the planning, execution, and post analysis stages of the characterization process. During the planning stage, the Knowledge Assistant suggests robot paths and speeds based on knowledge of sensors available and their physical characteristics. During execution, the Knowledge Assistant coordinates the collection of data through a data acquisition {open_quotes}specialist.{close_quotes} During execution and post analysis, the Knowledge Assistant sends raw data to other {open_quotes}specialists,{close_quotes} which include statistical pattern recognition software, a neuralmore » network, and model-based search software. After the specialists return their results, the Knowledge Assistant consolidates the information and returns a report to the robot control system where the sensed objects and their attributes (e.g. estimated dimensions, weight, material composition, etc.) are displayed in the world model. This paper highlights the major components of this system.« less

  8. Laparoscopy vs robotics in surgical management of endometrial cancer: comparison of intraoperative and postoperative complications.

    PubMed

    Seror, Julien; Bats, Anne-Sophie; Huchon, Cyrille; Bensaïd, Chérazade; Douay-Hauser, Nathalie; Lécuru, Fabrice

    2014-01-01

    To compare the rates of intraoperative and postoperative complications of robotic surgery and laparoscopy in the surgical treatment of endometrial cancer. Unicentric retrospective study (Canadian Task Force classification II-2). Tertiary teaching hospital. The study was performed from January 2002 to December 2011 and included patients with endometrial cancer who underwent laparoscopic or robotically assisted laparoscopic surgical treatment. Data collected included preoperative data, tumor characteristics, intraoperative data (route of surgery, surgical procedures, and complications), and postoperative data (early and late complications according to the Clavien-Dindo classification, and length of hospital stay). Morbidity was compared between the 2 groups. The study included 146 patients, of whom 106 underwent laparoscopy and 40 underwent robotically assisted surgery. The 2 groups were comparable in terms of demographic and preoperative data. Intraoperative complications occurred in 9.4% of patients who underwent laparoscopy and in none who underwent robotically assisted surgery (p = .06). There was no difference between the 2 groups in terms of postoperative events. Robotically assisted surgery is not associated with a significant difference in intraoperative and postoperative complications, even when there were no intraoperative complications of robotically assisted surgery. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  9. Robotic-assisted laparoscopic prostatectomy in umbilical hernia patients: University of California, Irvine, technique for port placement and repair.

    PubMed

    Kim, William; Abdelshehid, Corollos; Lee, Hak J; Ahlering, Thomas

    2012-06-01

    To discuss a technique currently used at our institution for the management of umbilical hernias during robot-assisted laparoscopic prostatectomy. As more patients undergo robot-assisted radical prostatectomy, there will be an increase in patients who qualify for robotic surgery with comorbidities. This technique has been utilized in clinically localized prostate cancer patients with umbilical hernias using the da Vinci Surgical System and standard laparoscopic instrumentation. Port placements and closures were performed by a resident assistant and a nurse at the operating table. The prostatectomy was performed by a single experienced surgeon at the console. Currently, no data are available regarding patients with umbilical hernias undergoing robotic prostatectomy. We reviewed our technique of port placement for patients with a pre-existing umbilical hernia undergoing robot-assisted laparoscopic prostatectomy. This technique allows for a reduction of the umbilical hernia, the use of the fascial defect as a robotic port, and the removal of the prostate by way of transverse incision and transverse repair. In our experience, this technique is feasible and reproducible for any small or large umbilical hernia. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Improvement of the insertion axis for cochlear implantation with a robot-based system.

    PubMed

    Torres, Renato; Kazmitcheff, Guillaume; De Seta, Daniele; Ferrary, Evelyne; Sterkers, Olivier; Nguyen, Yann

    2017-02-01

    It has previously reported that alignment of the insertion axis along the basal turn of the cochlea was depending on surgeon' experience. In this experimental study, we assessed technological assistances, such as navigation or a robot-based system, to improve the insertion axis during cochlear implantation. A preoperative cone beam CT and a mastoidectomy with a posterior tympanotomy were performed on four temporal bones. The optimal insertion axis was defined as the closest axis to the scala tympani centerline avoiding the facial nerve. A neuronavigation system, a robot assistance prototype, and software allowing a semi-automated alignment of the robot were used to align an insertion tool with an optimal insertion axis. Four procedures were performed and repeated three times in each temporal bone: manual, manual navigation-assisted, robot-based navigation-assisted, and robot-based semi-automated. The angle between the optimal and the insertion tool axis was measured in the four procedures. The error was 8.3° ± 2.82° for the manual procedure (n = 24), 8.6° ± 2.83° for the manual navigation-assisted procedure (n = 24), 5.4° ± 3.91° for the robot-based navigation-assisted procedure (n = 24), and 3.4° ± 1.56° for the robot-based semi-automated procedure (n = 12). A higher accuracy was observed with the semi-automated robot-based technique than manual and manual navigation-assisted (p < 0.01). Combination of a navigation system and a manual insertion does not improve the alignment accuracy due to the lack of friendly user interface. On the contrary, a semi-automated robot-based system reduces both the error and the variability of the alignment with a defined optimal axis.

  11. Avoiding and managing vascular injury during robotic-assisted radical prostatectomy

    PubMed Central

    Nunez Bragayrac, Luciano A.; Machuca, Victor; Garza Cortes, Roberto; Azhar, Raed A.

    2015-01-01

    There has been an increase in the number of urologic procedures performed robotically assisted; this is the case for radical prostatectomy. Currently, in the USA, 67% of prostatectomies are performed robotically assisted. With this increase in robotic urologic surgery it is clear that there are more surgeons in their learning curve, where most of the complications occur. Among the complications that can occur are vascular injuries. These can occur in the initial stages of surgery, such as in accessing the abdominal cavity, as well as in the intraoperative or postoperative setting. We present the most common vascular injuries in robot-assisted radical prostatectomy, as well as their management and prevention. We believe that it is of vital importance to be able to recognize these injuries so that they can be prevented. PMID:25642293

  12. Anesthetic Considerations in Robotic-Assisted Gynecologic Surgery

    PubMed Central

    Kaye, Alan D.; Vadivelu, Nalini; Ahuja, Nitin; Mitra, Sukanya; Silasi, Dan; Urman, Richard D.

    2013-01-01

    Background Robotic-assisted surgery has evolved over the past 2 decades with constantly improving technology that assists surgeons in multiple subspecialty disciplines. The surgical requirements of lithotomy and steep Trendelenburg positions, along with the creation of a pneumoperitoneum and lack of direct access to the patient all present management challenges in gynecologic surgery. Patient positioning requirements can have significant physiologic effects and can result in many complications. Methods This review focuses on the anesthetic and surgical implications of robot-assisted technology in gynecologic surgery. Conclusion Good communication among team members and knowledge of the nuances of robotic surgery have the potential to improve patient outcomes, increase efficiency, and reduce complications. PMID:24358000

  13. Intraoperative monitoring of marginal mandibular nerve during neck dissection.

    PubMed

    Tirelli, Giancarlo; Bergamini, Pier Riccardo; Scardoni, Alessandro; Gatto, Annalisa; Boscolo Nata, Francesca; Marcuzzo, Alberto Vito

    2018-05-01

    The purpose of this study was to assess the efficacy of intraoperative nerve integrity monitoring (NIM) to prevent marginal mandibular nerve injuries during neck dissection. This prospective study compared 36 patients undergoing NIM-assisted neck dissection from July 2014 to March 2015 to a cohort of 35 patients subjected to neck dissection over an identical period of time before the technique was introduced. We also assessed possible correlations between marginal mandibular nerve injuries and other factors, such as anthropometric measurements, presence of clinical neck metastases, type of neck dissection, and site of primary tumor. The incidence of marginal mandibular nerve paralyses was significantly lower among the group of patients undergoing NIM-assisted neck dissection (P = .021). There was no significant difference in the duration of the procedure, and the technique resulted in a limited increase of cost. No other factor seemed to influence the onset of marginal mandibular nerve palsy. In our opinion, NIM is a valuable aid for preventing marginal mandibular nerve injuries during neck dissection. © 2018 Wiley Periodicals, Inc.

  14. Authoring Robot-Assisted Instructional Materials for Improving Learning Performance and Motivation in EFL Classrooms

    ERIC Educational Resources Information Center

    Hong, Zeng-Wei; Huang, Yueh-Min; Hsu, Marie; Shen, Wei-Wei

    2016-01-01

    Anthropomorphized robots are regarded as beneficial tools in education due to their capabilities of improving teaching effectiveness and learning motivation. Therefore, one major trend of research, known as Robot- Assisted Language Learning (RALL), is trying to develop robots to support teaching and learning English as a foreign language (EFL). As…

  15. Significant impact of R.E.N.A.L. nephrometry score on changes in postoperative renal function early after robot-assisted partial nephrectomy.

    PubMed

    Miyake, Hideaki; Furukawa, Junya; Hinata, Nobuyuki; Muramaki, Mototsugu; Tanaka, Kazushi; Fujisawa, Masato

    2015-06-01

    Our objective was to evaluate the significance of the R.E.N.A.L. nephrometry score (RNS)--developed to quantitatively evaluate the complexity of renal tumors in a reproducible manner--in perioperative and renal functional outcomes following robot-assisted partial nephrectomy (RAPN). This study assessed 48 consecutive patients with renal tumors who underwent RAPN. Preoperative RNS for each patient was calculated, and its impact on several parameters associated with perioperative outcomes, including postoperative renal function, was investigated with Spearman's rank correlation test. Mean RNS in the 48 patients was 6.8; of these 48 patients, 21 (43.7%), 24 (50.0%), and three (6.3%) were classified into low-, moderate-, and high-complexity groups, respectively. The RNS was significantly correlated with resected tumor weight and postoperative changes in estimated glomerular filtration rate (eGFR) at both 1 and 4 weeks--but not age, body mass index (BMI), preoperative eGFR, operative time, warm ischemia time, estimated blood loss, postoperative complications, or eGFR-- after RAPN. No component of the RNS (R: radius; E: exophytic/endophytic properties; N: nearness of tumor to the collecting system or sinus; A: anterior/posterior; L: location relative to polar lines) alone had a significant impact on postoperative changes in eGFR at 1 and 4 weeks, whereas resected tumor weight was significantly associated with the R and E subcategories. Measurement of total RNS is useful for predicting renal functional outcomes early after RAPN.

  16. Knowing when to assist: developmental issues in lifelong assistive robotics.

    PubMed

    Demiris, Yiannis

    2009-01-01

    Children and adults with sensorimotor disabilities can significantly increase their autonomy through the use of assistive robots. As the field progresses from short-term, task-specific solutions to long-term, adaptive ones, new challenges are emerging. In this paper a lifelong methodological approach is presented, that attempts to balance the immediate context-specific needs of the user, with the long-term effects that the robot's assistance can potentially have on the user's developmental trajectory.

  17. Trunk Robot Rehabilitation Training with Active Stepping Reorganizes and Enriches Trunk Motor Cortex Representations in Spinal Transected Rats

    PubMed Central

    Oza, Chintan S.

    2015-01-01

    Trunk motor control is crucial for postural stability and propulsion after low thoracic spinal cord injury (SCI) in animals and humans. Robotic rehabilitation aimed at trunk shows promise in SCI animal models and patients. However, little is known about the effect of SCI and robot rehabilitation of trunk on cortical motor representations. We previously showed reorganization of trunk motor cortex after adult SCI. Non-stepping training also exacerbated some SCI-driven plastic changes. Here we examine effects of robot rehabilitation that promotes recovery of hindlimb weight support functions on trunk motor cortex representations. Adult rats spinal transected as neonates (NTX rats) at the T9/10 level significantly improve function with our robot rehabilitation paradigm, whereas treadmill-only trained do not. We used intracortical microstimulation to map motor cortex in two NTX groups: (1) treadmill trained (control group); and (2) robot-assisted treadmill trained (improved function group). We found significant robot rehabilitation-driven changes in motor cortex: (1) caudal trunk motor areas expanded; (2) trunk coactivation at cortex sites increased; (3) richness of trunk cortex motor representations, as examined by cumulative entropy and mutual information for different trunk representations, increased; (4) trunk motor representations in the cortex moved toward more normal topography; and (5) trunk and forelimb motor representations that SCI-driven plasticity and compensations had caused to overlap were segregated. We conclude that effective robot rehabilitation training induces significant reorganization of trunk motor cortex and partially reverses some plastic changes that may be adaptive in non-stepping paraplegia after SCI. PMID:25948267

  18. Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.

    PubMed

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-06-01

    This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.

  19. Robotic-assisted cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS-HIPEC).

    PubMed

    Gabriel, Emmanuel; Elli, Enrique; Bagaria, Sanjay; Wasif, Nabil; Grotz, Travis; Stauffer, John; Kasi, Pashtoon M; Asbun, Horacio

    2018-05-05

    Cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS-HIPEC) is an appropriate treatment for select patients with peritoneal carcinomatosis. While most commonly performed through an open incision, the laparoscopic approach has been reported and offers short-term benefits. A robotic-assisted approach for carcinomatosis of gastrointestinal origin, however, has not yet been described. We report our approach to robotic-assisted CRS-HIPEC for a patient with a perforated appendiceal mucocele. Our dynamic video highlights the advantages of this approach. Our patient was a 57-year-old woman with minimal residual disseminated peritoneal adenomucinosis (DPAM), having a peritoneal carcinomatosis index (PCI) score of 1. She had a previous surgical history of a Roux-en-Y gastric bypass. A robotic-assisted approach was utilized using the Intuitive daVinci Xi robotic surgical system through 4 ports. No laparoscopic assistant port was required. The operative time was 426 min, and the estimated blood loss was 50 cc. The greater omentum, falciform ligament, bilateral ovaries, and two small areas of tumor implant were resected. The post-operative length of stay was 4 days, and the patient had regained bowel function by post-operative day 2. Our video demonstrates the feasibility of a robotic-assisted CRS-HIPEC in a patient with minimal, residual DPAM. Similar to a laparoscopic approach, the short-term outcomes are improved as compared to an open approach. An MIS approach to CRS-HIPEC, now with the first-reported robotic-assisted approach, is a viable option for select patients with peritoneal tumors.

  20. The economics of robotic cystectomy: cost comparison of open versus robotic cystectomy.

    PubMed

    Lee, Richard; Ng, Casey K; Shariat, Shahrokh F; Borkina, Anna; Guimento, Robert; Brumit, Kevin F; Scherr, Douglas S

    2011-12-01

    • To assess and compare the economic burden of open radical cystectomy (OC) vs robotic-assisted laparoscopic radical cystectomy (RC) with pelvic lymph node dissection and urinary diversion. • A series of 103 and 83 consecutive patients undergoing OC and RC, respectively, were prospectively studied at a tertiary care institution from April 2002 to February 2009. • Data were collected on patient demographics, perioperative parameters and length of stay (LOS) in hospital. Cohorts were subdivided into ileal conduit (IC), continent cutaneous diversion (CCD) and orthotopic neobladder (ON) subgroups. • A linear cost model was created to simulate treatment with OC vs RC. Procedural costs were derived from the Medicare Resource Based Relative Value Scale. Materials costs were obtained from the respective suppliers. The indirect costs of complications were considered. • Sensitivity analyses were performed. • Despite a higher cost of materials, RC was less expensive than OC for IC and CCD, although the cost advantage deteriorated for ON. • The per-case costs of RC with IC, CCD and ON were $20,659, $22,102 and $22,685, respectively, compared to $25,505, $22,697 and $20,719 for their OC counterparts. • The largest cost driver in the study was LOS in hospital. • RC showed a shorter LOS compared to OC, although this effect was insufficient to offset the higher cost of robotic surgery. • Complications materially affected cost performance. • Despite a higher cost of materials, RC can be more cost efficient than OC as a treatment for bladder cancer at a high-volume, tertiary care referral centre, particularly with IC. • Complications significantly impact cost performance. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  1. Robotic Low Ligation of the Inferior Mesenteric Artery for Rectal Cancer Using the Firefly Technique.

    PubMed

    Bae, Sung Uk; Min, Byung Soh; Kim, Nam Kyu

    2015-07-01

    By integrating intraoperative near infrared fluorescence imaging into a robotic system, surgeons can identify the vascular anatomy in real-time with the technical advantages of robotics that is useful for meticulous lymphovascular dissection. Herein, we report our initial experience of robotic low ligation of the inferior mesenteric artery (IMA) with real-time identification of the vascular system for rectal cancer using the Firefly technique. The study group included 11 patients who underwent a robotic total mesorectal excision with preservation of the left colic artery for rectal cancer using the Firefly technique between July 2013 and December 2013. The procedures included five low anterior resections and six ultra-low anterior resections with loop ileostomy. The median total operation time was 327 min (226-490). The low ligation time was 10 min (6-20), and the time interval between indocyanine green injection and division of the sigmoid artery was 5 min (2-8). The estimated blood loss was 200 mL (100-500). The median time to soft diet was 4 days (4-5), and the median length of stay was 7 days (5-9). Three patients developed postoperative complications; one patients developed anal stricture, one developed ileus, and one developed non-complicated intraabdominal fluid collection. The median total number of lymph nodes harvested was 17 (9-29). Robotic low ligation of the IMA with real-time identification of the vascular system for rectal cancer using the Firefly technique is safe and feasible. This technique can allow for precise lymph node dissection along the IMA and facilitate the identification of the left colic branch of the IMA.

  2. Our Experiences with Robot-Assisted Laparoscopic Radical Cystectomy: Orthotopic Neobladder by the Suprapubic Incision Method

    PubMed Central

    Cho, Byung Chul; Jung, Ha Bum; Cho, Sung Tae; Kim, Ki Kyung; Han, Jun Hyun; Lee, Yong Seong

    2012-01-01

    Purpose To report our technique for and experience with robot-assisted laparoscopic radical cystectomy (RARC) with orthotopic neobladder (ON) formation in a cohort of bladder cancer patients. Materials and Methods Between December 2007 and December 2011, a total of 35 patients underwent RARC. The patients' mean age was 63.3 years and their mean body mass index was 23.7 kg/m2. Thirty patients had a clinical stage of T2 or higher. Postoperative mean follow-up duration was 25.5 months. In 5 patients, a 4-cm midline infraumbilical skin incision was made for an ileal conduit (IC) and the stoma formation was similar to the open procedure. In 30 patients undergoing the ON procedure, the skin for specimen removal and extracorporeal enterocystoplasty was incised infraumbilically in the early 5 cases with redocking (ON-I) and suprapubically in the latter 25 cases without redocking (ON-S). Results The mean operative times of the IC, ON-I, and ON-S groups were 442.5, 646.0, and 531.3 minutes, respectively (p=0.001). Mean console and lymph node dissection time were not significantly different between the groups. Mean urinary diversion times in each group were 68.8, 125.0, and 118.8 minutes, respectively (p=0.001). In the comparison between the ON-I and ON-S group, only operative time was significant. Four patients required a blood transfusion. We had no cases of intraabdominal organ injury or open conversion. Thiry-three patients (94.2%) had a pathologic stage of T2 or higher. Two patients (5.7%) had lymph node-positive disease. Postoperative complications included ileus (n=4), stricture in the uretero-ileal junction (n=2), and vesicovaginal fistula (n=1). Conclusions Our robotic neobladder-suprapubic incision without redocking procedure is easier and more rapid than that of infraumbilical incision with redocking. PMID:23185668

  3. Robotic technology in surgery: current status in 2008.

    PubMed

    Murphy, Declan G; Hall, Rohan; Tong, Raymond; Goel, Rajiv; Costello, Anthony J

    2008-12-01

    There is increasing patient and surgeon interest in robotic-assisted surgery, particularly with the proliferation of da Vinci surgical systems (Intuitive Surgical, Sunnyvale, CA, USA) throughout the world. There is much debate over the usefulness and cost-effectiveness of these systems. The currently available robotic surgical technology is described. Published data relating to the da Vinci system are reviewed and the current status of surgical robotics within Australia and New Zealand is assessed. The first da Vinci system in Australia and New Zealand was installed in 2003. Four systems had been installed by 2006 and seven systems are currently in use. Most of these are based in private hospitals. Technical advantages of this system include 3-D vision, enhanced dexterity and improved ergonomics when compared with standard laparoscopic surgery. Most procedures currently carried out are urological, with cardiac, gynaecological and general surgeons also using this system. The number of patients undergoing robotic-assisted surgery in Australia and New Zealand has increased fivefold in the past 4 years. The most common procedure carried out is robotic-assisted laparoscopic radical prostatectomy. Published data suggest that robotic-assisted surgery is feasible and safe although the installation and recurring costs remain high. There is increasing acceptance of robotic-assisted surgery, especially for urological procedures. The da Vinci surgical system is becoming more widely available in Australia and New Zealand. Other surgical specialties will probably use this technology. Significant costs are associated with robotic technology and it is not yet widely available to public patients.

  4. Training and learning robotic surgery, time for a more structured approach: a systematic review.

    PubMed

    Schreuder, H W R; Wolswijk, R; Zweemer, R P; Schijven, M P; Verheijen, R H M

    2012-01-01

    Robotic assisted laparoscopic surgery is growing rapidly and there is an increasing need for a structured approach to train future robotic surgeons. To review the literature on training and learning strategies for robotic assisted laparoscopic surgery. A systematic search of MEDLINE, EMBASE, the Cochrane Library and the Journal of Robotic Surgery was performed. We included articles concerning training, learning, education and teaching of robotic assisted laparoscopic surgery in any specialism. Two authors independently selected articles to be included. We categorised the included articles into: training modalities, learning curve, training future surgeons, curriculum design and implementation. We included 114 full text articles. Training modalities such as didactic training, skills training (dry lab, virtual reality, animal or cadaver models), case observation, bedside assisting, proctoring and the mentoring console can be used for training in robotic assisted laparoscopic surgery. Several training programmes in general and specific programmes designed for residents, fellows and surgeons are described in the literature. We provide guidelines for development of a structured training programme. Robotic surgical training consists of system training and procedural training. System training should be formally organised and should be competence based, instead of time based. Virtual reality training will play an import role in the near future. Procedural training should be organised in a stepwise approach with objective assessment of each step. This review aims to facilitate and improve the implementation of structured robotic surgical training programmes. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

  5. [Prostatectomy-pros and cons on open surgery/laparoscopic surgery/robot-assisted surgery].

    PubMed

    Abe, Mitsuhiro; Kawano, Yoshiyuki; Kameyama, Shuji

    2011-12-01

    We have 3 options when perfoming prostatectomy for the treatment of localized prostate cancer. Those are retropubic radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted laparoscopic radical prostatectomy. We compared the characteristics and results of these techniques. Robot-assisted laparoscopic radical prostatectomy could be superior to the others in many ways. However, it would be very difficult to adopt it in Japan because it would pose economical difficulties. The administrative assistance in the insurance systems requireds much more than we have.

  6. Robotic-assisted real-time MRI-guided TAVR: from system deployment to in vivo experiment in swine model.

    PubMed

    Chan, Joshua L; Mazilu, Dumitru; Miller, Justin G; Hunt, Timothy; Horvath, Keith A; Li, Ming

    2016-10-01

    Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constrained procedural environment. To address these concerns, a magnetic resonance (MR)-compatible robotic system to assist in TAVR deployments was developed. This study evaluates the technical design and interface considerations of an MR-compatible robotic-assisted TAVR system with the purpose of demonstrating that such a system can be developed and executed safely and precisely in a preclinical model. An MR-compatible robotic surgical assistant system was built for TAVR deployment. This system integrates a 5-degrees of freedom (DoF) robotic arm with a 3-DoF robotic valve delivery module. A user interface system was designed for procedural planning and real-time intraoperative manipulation of the robot. The robotic device was constructed of plastic materials, pneumatic actuators, and fiber-optical encoders. The mechanical profile and MR compatibility of the robotic system were evaluated. The system-level error based on a phantom model was 1.14 ± 0.33 mm. A self-expanding prosthesis was successfully deployed in eight Yorkshire swine under rtMRI guidance. Post-deployment imaging and necropsy confirmed placement of the stent within 3 mm of the aortic valve annulus. These phantom and in vivo studies demonstrate the feasibility and advantages of robotic-assisted TAVR under rtMRI guidance. This robotic system increases the precision of valve deployments, diminishes environmental constraints, and improves the overall success of TAVR.

  7. Comparative Effectiveness of Cancer Control and Survival after Robot-Assisted versus Open Radical Prostatectomy.

    PubMed

    Hu, Jim C; O'Malley, Padraic; Chughtai, Bilal; Isaacs, Abby; Mao, Jialin; Wright, Jason D; Hershman, Dawn; Sedrakyan, Art

    2017-01-01

    Robot-assisted surgery has been rapidly adopted in the U.S. for prostate cancer. Its adoption has been driven by market forces and patient preference, and debate continues regarding whether it offers improved outcomes to justify the higher cost relative to open surgery. We examined the comparative effectiveness of robot-assisted vs open radical prostatectomy in cancer control and survival in a nationally representative population. This population based observational cohort study of patients with prostate cancer undergoing robot-assisted radical prostatectomy and open radical prostatectomy during 2003 to 2012 used data captured in the SEER (Surveillance, Epidemiology, and End Results)-Medicare linked database. Propensity score matching and time to event analysis were used to compare all cause mortality, prostate cancer specific mortality and use of additional treatment after surgery. A total of 6,430 robot-assisted radical prostatectomies and 9,161 open radical prostatectomies performed during 2003 to 2012 were identified. The use of robot-assisted radical prostatectomy increased from 13.6% in 2003 to 2004 to 72.6% in 2011 to 2012. After a median followup of 6.5 years (IQR 5.2-7.9) robot-assisted radical prostatectomy was associated with an equivalent risk of all cause mortality (HR 0.85, 0.72-1.01) and similar cancer specific mortality (HR 0.85, 0.50-1.43) vs open radical prostatectomy. Robot-assisted radical prostatectomy was also associated with less use of additional treatment (HR 0.78, 0.70-0.86). Robot-assisted radical prostatectomy has comparable intermediate cancer control as evidenced by less use of additional postoperative cancer therapies and equivalent cancer specific and overall survival. Longer term followup is needed to assess for differences in prostate cancer specific survival, which was similar during intermediate followup. Our findings have significant quality and cost implications, and provide reassurance regarding the adoption of more expensive technology in the absence of randomized controlled trials. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. A Systematic Review of Virtual Reality Simulators for Robot-assisted Surgery.

    PubMed

    Moglia, Andrea; Ferrari, Vincenzo; Morelli, Luca; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred

    2016-06-01

    No single large published randomized controlled trial (RCT) has confirmed the efficacy of virtual simulators in the acquisition of skills to the standard required for safe clinical robotic surgery. This remains the main obstacle for the adoption of these virtual simulators in surgical residency curricula. To evaluate the level of evidence in published studies on the efficacy of training on virtual simulators for robotic surgery. In April 2015 a literature search was conducted on PubMed, Web of Science, Scopus, Cochrane Library, the Clinical Trials Database (US) and the Meta Register of Controlled Trials. All publications were scrutinized for relevance to the review and for assessment of the levels of evidence provided using the classification developed by the Oxford Centre for Evidence-Based Medicine. The publications included in the review consisted of one RCT and 28 cohort studies on validity, and seven RCTs and two cohort studies on skills transfer from virtual simulators to robot-assisted surgery. Simulators were rated good for realism (face validity) and for usefulness as a training tool (content validity). However, the studies included used various simulation training methodologies, limiting the assessment of construct validity. The review confirms the absence of any consensus on which tasks and metrics are the most effective for the da Vinci Skills Simulator and dV-Trainer, the most widely investigated systems. Although there is consensus for the RoSS simulator, this is based on only two studies on construct validity involving four exercises. One study on initial evaluation of an augmented reality module for partial nephrectomy using the dV-Trainer reported high correlation (r=0.8) between in vivo porcine nephrectomy and a virtual renorrhaphy task according to the overall Global Evaluation Assessment of Robotic Surgery (GEARS) score. In one RCT on skills transfer, the experimental group outperformed the control group, with a significant difference in overall GEARS score (p=0.012) during performance of urethrovesical anastomosis on an inanimate model. Only one study included assessment of a surgical procedure on real patients: subjects trained on a virtual simulator outperformed the control group following traditional training. However, besides the small numbers, this study was not randomized. There is an urgent need for a large, well-designed, preferably multicenter RCT to study the efficacy of virtual simulation for acquisition competence in and safe execution of clinical robotic-assisted surgery. We reviewed the literature on virtual simulators for robot-assisted surgery. Validity studies used various simulation training methodologies. It is not clear which exercises and metrics are the most effective in distinguishing different levels of experience on the da Vinci robot. There is no reported evidence of skills transfer from simulation to clinical surgery on real patients. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  9. Robotic Arm-Assisted Sonography: Review of Technical Developments and Potential Clinical Applications.

    PubMed

    Swerdlow, Daniel R; Cleary, Kevin; Wilson, Emmanuel; Azizi-Koutenaei, Bamshad; Monfaredi, Reza

    2017-04-01

    Ultrasound imaging requires trained personnel. Advances in robotics and data transmission create the possibility of telesonography. This review introduces clinicians to current technical work in and potential applications of this developing capability. Telesonography offers advantages in hazardous or remote environments. Robotically assisted ultrasound can reduce stress injuries in sonographers and has potential utility during robotic surgery and interventional procedures.

  10. An economic analysis of robotically assisted hysterectomy.

    PubMed

    Wright, Jason D; Ananth, Cande V; Tergas, Ana I; Herzog, Thomas J; Burke, William M; Lewin, Sharyn N; Lu, Yu-Shiang; Neugut, Alfred I; Hershman, Dawn L

    2014-05-01

    To perform an econometric analysis to examine the influence of procedure volume, variation in hospital accounting methodology, and use of various analytic methodologies on cost of robotically assisted hysterectomy for benign gynecologic disease and endometrial cancer. A national sample was used to identify women who underwent laparoscopic or robotically assisted hysterectomy for benign indications or endometrial cancer from 2006 to 2012. Surgeon and hospital volume were classified as the number of procedures performed before the index surgery. Total costs as well as fixed and variable costs were modeled using multivariable quantile regression methodology. A total of 180,230 women, including 169,324 women who underwent minimally invasive hysterectomy for benign indications and 10,906 patients whose hysterectomy was performed for endometrial cancer, were identified. The unadjusted median cost of robotically assisted hysterectomy for benign indications was $8,152 (interquartile range [IQR] $6,011-10,932) compared with $6,535 (IQR $5,127-8,357) for laparoscopic hysterectomy (P<.001). The cost differential decreased with increasing surgeon and hospital volume. The unadjusted median cost of robotically assisted hysterectomy for endometrial cancer was $9,691 (IQR $7,591-12,428) compared with $8,237 (IQR $6,400-10,807) for laparoscopic hysterectomy (P<.001). The cost differential decreased with increasing hospital volume from $2,471 for the first 5 to 15 cases to $924 for more than 50 cases. Based on surgeon volume, robotically assisted hysterectomy for endometrial cancer was $1,761 more expensive than laparoscopy for those who had performed fewer than five cases; the differential declined to $688 for more than 50 procedures compared with laparoscopic hysterectomy. The cost of robotic gynecologic surgery decreases with increased procedure volume. However, in all of the scenarios modeled, robotically assisted hysterectomy remained substantially more costly than laparoscopic hysterectomy.

  11. Evaluating the effect of three-dimensional visualization on force application and performance time during robotics-assisted mitral valve repair.

    PubMed

    Currie, Maria E; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W A; Patel, Rajni; Peters, Terry; Kiaii, Bob B

    2013-01-01

    The purpose of this study was to determine the effect of three-dimensional (3D) binocular, stereoscopic, and two-dimensional (2D) monocular visualization on robotics-assisted mitral valve annuloplasty versus conventional techniques in an ex vivo animal model. In addition, we sought to determine whether these effects were consistent between novices and experts in robotics-assisted cardiac surgery. A cardiac surgery test-bed was constructed to measure forces applied during mitral valve annuloplasty. Sutures were passed through the porcine mitral valve annulus by the participants with different levels of experience in robotics-assisted surgery and tied in place using both robotics-assisted and conventional surgery techniques. The mean time for both the experts and the novices using 3D visualization was significantly less than that required using 2D vision (P < 0.001). However, there was no significant difference in the maximum force applied by the novices to the mitral valve during suturing (P = 0.7) and suture tying (P = 0.6) using either 2D or 3D visualization. The mean time required and forces applied by both the experts and the novices were significantly less using the conventional surgical technique than when using the robotic system with either 2D or 3D vision (P < 0.001). Despite high-quality binocular images, both the experts and the novices applied significantly more force to the cardiac tissue during 3D robotics-assisted mitral valve annuloplasty than during conventional open mitral valve annuloplasty. This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery.

  12. Flexible Carbon Dioxide Laser Fiber Versus Ultrasonic Scalpel in Robot-Assisted Laparoscopic Myomectomy.

    PubMed

    Choussein, Souzana; Srouji, Serene S; Farland, Leslie V; Gargiulo, Antonio R

    2015-01-01

    To compare the effectiveness and safety of a flexible carbon dioxide (CO2) laser fiber to the ultrasonic scalpel when employed through a robotic surgical system. Retrospective cohort study. Level II-2 evidence. Reproductive surgery practice at an academic hospital. Two hundred thirty-six women who had undergone robot-assisted laparoscopic myomectomy with either CO2 laser (n = 85) or the ultrasonic scalpel (n = 151). Robot-assisted laparoscopic myomectomy employing either a flexible CO2 laser fiber or a robotic ultrasonic scalpel as the primary energy tool. Perioperative outcomes (estimated blood loss, operative time, length of hospital stay) of patients undergoing robot-assisted myomectomy with a flexible laser fiber or ultrasonic scalpel. Estimated blood loss and operative time were comparable (p = .95 and p = .55, respectively) between the 2 groups after adjusting for all confounders, whereas length of hospital stay remained significantly different (p = .004). Odds ratio for complications was 0.35 (95% confidence interval 0.08-1.56; p = .17), which denotes no difference in the risk for complications between the 2 groups. Robot-assisted laparoscopic myomectomy with a flexible CO2 laser fiber is safe and has comparable operative outcomes to the ultrasonic scalpel. The small size and flexibility of this device allows robotic surgeons to employ safe focal energy without sacrificing operative ergonomics. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  13. Robot-assisted laparoscopic staging surgery for endometrial cancer--a preliminary report.

    PubMed

    Lee, Chyi-Long; Han, Chien-Min; Su, Hsuan; Wu, Kai-Yun; Wang, Chin-Jung; Yen, Chih-Feng

    2010-12-01

    The robotic surgical system is reported to overcome some technical difficulties in traditional laparoscopic hysterectomy. This study aimed to evaluate the feasibility and surgical outcomes of a robotic surgery program for endometrial cancer. Patients with endometrial cancer with the intention to receive treatment using robot-assisted laparoscopic staging surgery were recruited in a university hospital from July 2007 to August 2008. All of these surgeries were performed with the da Vinci system. Six patients (mean age, 47.5 ±1.4 years; mean body mass index, 26.2 ±3.5 kg/m(2)) were enrolled and completed robot-assisted laparoscopic staging surgery. The robot docking time was 45.0 ±13.6 minutes and the robot-assisted operation time was 200.3 ±30.0 minutes. The mean estimated blood loss was 180.0 ±147.6 mL. The mean number of lymph nodes retrieved was 23.2 ±7.4. No laparoconversion and no intraoperative or postoperative complications occurred. All patients were alive and free of disease up to the date of this report, at a median follow-up of 6.5 months (range, 5-17 months). Robot-assisted laparoscopic staging surgery is a feasible treatment and helps overcome the technical limitations in conventional laparoscopy for endometrial cancer. Copyright © 2010 Taiwan Association of Obstetric & Gynecology. Published by Elsevier B.V. All rights reserved.

  14. Intuitive adaptive orientation control of assistive robots for people living with upper limb disabilities.

    PubMed

    Vu, Dinh-Son; Allard, Ulysse Cote; Gosselin, Clement; Routhier, Francois; Gosselin, Benoit; Campeau-Lecours, Alexandre

    2017-07-01

    Robotic assistive devices enhance the autonomy of individuals living with physical disabilities in their day-to-day life. Although the first priority for such devices is safety, they must also be intuitive and efficient from an engineering point of view in order to be adopted by a broad range of users. This is especially true for assistive robotic arms, as they are used for the complex control tasks of daily living. One challenge in the control of such assistive robots is the management of the end-effector orientation which is not always intuitive for the human operator, especially for neophytes. This paper presents a novel orientation control algorithm designed for robotic arms in the context of human-robot interaction. This work aims at making the control of the robot's orientation easier and more intuitive for the user, in particular, individuals living with upper limb disabilities. The performance and intuitiveness of the proposed orientation control algorithm is assessed through two experiments with 25 able-bodied subjects and shown to significantly improve on both aspects.

  15. Surgical outcomes of robotic-assisted surgical staging for endometrial cancer are equivalent to traditional laparoscopic staging at a minimally invasive surgical center

    PubMed Central

    Cardenas-Goicoechea, Joel; Adams, Sarah; Bhat, Suneel B.; Randall, Thomas C.

    2010-01-01

    Objective To compare peri- and post-operative complications and outcomes of robotic-assisted surgical staging with traditional laparoscopic surgical staging for women with endometrial cancer. Methods A retrospective chart review of cases of women undergoing minimally invasive total hysterectomy and pelvic and para-aortic lymphadenectomy by a robotic-assisted approach or traditional laparoscopic approach was conducted. Major intraoperative complications, including vascular injury, enterotomy, cystotomy, or conversion to laparotomy, were measured. Secondary outcomes including operative time, blood loss, transfusion rate, number of lymph nodes retrieved, and the length of hospitalization were also measured. Results 275 cases were identified–102 patients with robotic-assisted staging and 173 patients with traditional laparoscopic staging. There was no significant difference in the rate of major complications between groups (p=0.13). The mean operative time was longer in cases of robotic-assisted staging (237 min vs. 178 min, p<0.0001); however, blood loss was significantly lower (109 ml vs. 187 ml, p<0.0001). The mean number of lymph nodes retrieved were similar between groups (p=0.32). There were no significant differences in the time to discharge, re-admission, or re-operation rates between the two groups. Conclusion Robotic-assisted surgery is an acceptable alternative to laparoscopy for minimally invasive staging of endometrial cancer. In addition to the improved ease of operation, visualization, and range of motion of the robotic instruments, robotic surgery results in a lower mean blood loss, although longer operative time. More data are needed to determine if the rates of urinary tract injuries and other surgical complications can be reduced with the use of robotic surgery. PMID:20144471

  16. Effect of Gravity on Robot-Assisted Motor Training After Chronic Stroke: A Randomized Trial

    PubMed Central

    Conroy, Susan S.; Whitall, Jill; Dipietro, Laura; Jones-Lush, Lauren M.; Zhan, Min; Finley, Margaret A.; Wittenberg, George F.; Krebs, Hermano I.; Bever, Christopher T.

    2015-01-01

    Objectives To determine the efficacy of 2 distinct 6-week robot-assisted reaching programs compared with an intensive conventional arm exercise program (ICAE) for chronic, stroke-related upper-extremity (UE) impairment. To examine whether the addition of robot-assisted training out of the horizontal plane leads to improved outcomes. Design Randomized controlled trial, single-blinded, with 12-week follow-up. Setting Research setting in a large medical center. Participants Adults (N=62) with chronic, stroke-related arm weakness stratified by impairment severity using baseline UE motor assessments. Interventions Sixty minutes, 3 times a week for 6 weeks of robot-assisted planar reaching (gravity compensated), combined planar with vertical robot-assisted reaching, or intensive conventional arm exercise program. Main Outcome Measure UE Fugl-Meyer Assessment (FMA) mean change from baseline to final training. Results All groups showed modest gains in the FMA from baseline to final with no significant between group differences. Most change occurred in the planar robot group (mean change ± SD, 2.94± 0.77; 95% confidence interval [CI], 1.40 – 4.47). Participants with greater motor impairment (n=41) demonstrated a larger difference in response (mean change ± SD, 2.29±0.72; 95% CI, 0.85–3.72) for planar robot-assisted exercise compared with the intensive conventional arm exercise program (mean change ± SD, 0.43±0.72; 95% CI, −1.00 to 1.86). Conclusions Chronic UE deficits because of stroke are responsive to intensive motor task training. However, training outside the horizontal plane in a gravity present environment using a combination of vertical with planar robots was not superior to training with the planar robot alone. PMID:21849168

  17. Systematic review of published studies on safety and efficacy of thoracoscopic and robot-assisted lobectomy for lung cancer.

    PubMed

    Nakamura, Hiroshige

    2014-01-01

    The safety and efficacy of thoracoscopic and robot-assisted lobectomies for primary lung cancer were reviewed in the literature. Thoracoscopic surgery is less invasive compared to thoracotomy, and it has been reported to be superior with regard to the outcome. In addition, the operability of a surgical robot (da Vinci) is favorable and supplements the disadvantages of conventional endoscopic surgery. Robot-assisted lobectomy has been reported to be comparable to thoracoscopic surgery with regard to the safety and efficacy based on analysis of perioperative results and superior with regard to the operability and length of the learning curve. However, a high cost and a long operative time are of concern. Since robot-assisted surgery has been performed only in early cases, the continuation of a comparative investigation may be necessary.

  18. Robot-Assisted Laparoscopic Repair of Spontaneous Appendicovesical Fistula

    PubMed Central

    Kibar, Yusuf; Yalcin, Serdar; Kopru, Burak; Topuz, Bahadir; Ebiloglu, Turgay

    2016-01-01

    Abstract Background: To report the first case of the spontaneous appendicovesical fistulas' (AVF) repair with robot assisted laparoscopy. Case Presentation: A 29-year-old male patient with urgent persistant bacteriuria and dysuria was referred to our clinic. Physical examination and blood tests were normal. He had used various antibiotics due to recurrent UTI for about 20 years. Computed tomography revealed the fistula tract between the distal end of the appendix and right lateral wall of the bladder dome. He was successfully treated with robot-assisted laparoscopic repair. Following this surgery, the patient's complaints were resolved completely. Conclusion: AVF is the rare condition. Robot-assisted laparoscopy repair of AVF is safe and effective treatment option. PMID:27579435

  19. High level functions for the intuitive use of an assistive robot.

    PubMed

    Lebec, Olivier; Ben Ghezala, Mohamed Walid; Leynart, Violaine; Laffont, Isabelle; Fattal, Charles; Devilliers, Laurence; Chastagnol, Clement; Martin, Jean-Claude; Mezouar, Youcef; Korrapatti, Hermanth; Dupourqué, Vincent; Leroux, Christophe

    2013-06-01

    This document presents the research project ARMEN (Assistive Robotics to Maintain Elderly People in a Natural environment), aimed at the development of a user friendly robot with advanced functions for assistance to elderly or disabled persons at home. Focus is given to the robot SAM (Smart Autonomous Majordomo) and its new features of navigation, manipulation, object recognition, and knowledge representation developed for the intuitive supervision of the robot. The results of the technical evaluations show the value and potential of these functions for practical applications. The paper also documents the details of the clinical evaluations carried out with elderly and disabled persons in a therapeutic setting to validate the project.

  20. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    PubMed Central

    Wang, Jun-Qiang; Wang, Yu; Feng, Yun; Han, Wei; Su, Yong-Gang; Liu, Wen-Yong; Zhang, Wei-Jun; Wu, Xin-Bao; Wang, Man-Yi; Fan, Yu-Bo

    2017-01-01

    Background: Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique. Methods: Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws’ positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed. Results: Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide wire attempts in the robot-assisted group was significantly less than that in the freehand group (median [Q1, Q3]: 1.0 [1.0,1.0] time vs. median [Q1, Q3]: 7.0 [1.0, 9.0] times; χ2 = 15.771, respectively, P < 0.001). The instrumented SI levels did not differ between both groups (from S1 to S2, χ2 = 4.760, P = 0.093). Conclusions: Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible. PMID:29067950

  1. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique.

    PubMed

    Wang, Jun-Qiang; Wang, Yu; Feng, Yun; Han, Wei; Su, Yong-Gang; Liu, Wen-Yong; Zhang, Wei-Jun; Wu, Xin-Bao; Wang, Man-Yi; Fan, Yu-Bo

    2017-11-05

    Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique. Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws' positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed. Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide wire attempts in the robot-assisted group was significantly less than that in the freehand group (median [Q1, Q3]: 1.0 [1.0,1.0] time vs. median [Q1, Q3]: 7.0 [1.0, 9.0] times; χ2 = 15.771, respectively, P < 0.001). The instrumented SI levels did not differ between both groups (from S1 to S2, χ2 = 4.760, P = 0.093). Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible.

  2. Robot-assisted therapy for improving social interactions and activity participation among institutionalized older adults: a pilot study.

    PubMed

    Sung, Huei-Chuan; Chang, Shu-Min; Chin, Mau-Yu; Lee, Wen-Li

    2015-03-01

    Animal-assisted therapy is gaining popularity as part of therapeutic activities for older adults in many long-term care facilities. However, concerns about dog bites, allergic responses to pets, disease, and insufficient available resources to care for a real pet have led to many residential care facilities to ban this therapy. There are situations where a substitute artificial companion, such as robotic pet, may serve as a better alternative. This pilot study used a one-group pre- and posttest design to evaluate the effect of a robot-assisted therapy for older adults. Sixteen eligible participants participated in the study and received a group robot-assisted therapy using a seal-like robot pet for 30 minutes twice a week for 4 weeks. All participants received assessments of their communication and interaction skills using the Assessment of Communication and Interaction Skills (ACIS-C) and activity participation using the Activity Participation Scale at baseline and at week 4. A total of 12 participants completed the study. Wilcoxon signed rank test showed that participants' communication and interaction skills (z = -2.94, P = 0.003) and activity participation (z = -2.66, P = 0.008) were significantly improved after receiving 4-week robot-assisted therapy. By interacting with a robot pet, such as Paro, the communication, interaction skills, and activity participation of the older adults can be improved. The robot-assisted therapy can be provided as a routine activity program and has the potential to improve social health of older adults in residential care facilities. Copyright © 2014 Wiley Publishing Asia Pty Ltd.

  3. Comparison of success rates, learning curves, and inter-subject performance variability of robot-assisted and manual ultrasound-guided nerve block needle guidance in simulation.

    PubMed

    Morse, J; Terrasini, N; Wehbe, M; Philippona, C; Zaouter, C; Cyr, S; Hemmerling, T M

    2014-06-01

    This study focuses on a recently developed robotic nerve block system and its impact on learning regional anaesthesia skills. We compared success rates, learning curves, performance times, and inter-subject performance variability of robot-assisted vs manual ultrasound (US)-guided nerve block needle guidance. The hypothesis of this study is that robot assistance will result in faster skill acquisition than manual needle guidance. Five co-authors with different experience with nerve blocks and the robotic system performed both manual and robot-assisted, US-guided nerve blocks on two different nerves of a nerve phantom. Ten trials were performed for each of the four procedures. Time taken to move from a shared starting position till the needle was inserted into the target nerve was defined as the performance time. A successful block was defined as the insertion of the needle into the target nerve. Average performance times were compared using analysis of variance. P<0.05 was considered significant. Data presented as mean (standard deviation). All blocks were successful. There were significant differences in performance times between co-authors to perform the manual blocks, either superficial (P=0.001) or profound (P=0.0001); no statistical difference between co-authors was noted for the robot-assisted blocks. Linear regression indicated that the average decrease in time between consecutive trials for robot-assisted blocks of 1.8 (1.6) s was significantly (P=0.007) greater than the decrease for manual blocks of 0.3 (0.3) s. Robot assistance of nerve blocks allows for faster learning of needle guidance over manual positioning and reduces inter-subject performance variability. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Effectiveness of robot-assisted therapy on ankle rehabilitation – a systematic review

    PubMed Central

    2013-01-01

    Objective The aim of this study was to provide a systematic review of studies that investigated the effectiveness of robot-assisted therapy on ankle motor and function recovery from musculoskeletal or neurologic ankle injuries. Methods Thirteen electronic databases of articles published from January, 1980 to June, 2012 were searched using keywords ‘ankle*’, ‘robot*’, ‘rehabilitat*’ or ‘treat*’ and a free search in Google Scholar based on effects of ankle rehabilitation robots was also conducted. References listed in relevant publications were further screened. Eventually, twenty-nine articles were selected for review and they focused on effects of robot-assisted ankle rehabilitation. Results Twenty-nine studies met the inclusion criteria and a total of 164 patients and 24 healthy subjects participated in these trials. Ankle performance and gait function were the main outcome measures used to assess the therapeutic effects of robot-assisted ankle rehabilitation. The protocols and therapy treatments were varied, which made comparison among different studies difficult or impossible. Few comparative trials were conducted among different devices or control strategies. Moreover, the majority of study designs met levels of evidence that were no higher than American Academy for Cerebral Palsy (CP) and Developmental Medicine (AACPDM) level IV. Only one study used a Randomized Control Trial (RCT) approach with the evidence level being II. Conclusion All the selected studies showed improvements in terms of ankle performance or gait function after a period of robot-assisted ankle rehabilitation training. The most effective robot-assisted intervention cannot be determined due to the lack of universal evaluation criteria for various devices and control strategies. Future research into the effects of robot-assisted ankle rehabilitation should be carried out based on universal evaluation criteria, which could determine the most effective method of intervention. It is also essential to conduct trials to analyse the differences among different devices or control strategies. PMID:23517734

  5. Evaluation of surgical strategy of conventional vs. percutaneous robot-assisted spinal trans-pedicular instrumentation in spondylodiscitis.

    PubMed

    Keric, Naureen; Eum, David J; Afghanyar, Feroz; Rachwal-Czyzewicz, Izabela; Renovanz, Mirjam; Conrad, Jens; Wesp, Dominik M A; Kantelhardt, Sven R; Giese, Alf

    2017-03-01

    Robot-assisted percutaneous insertion of pedicle screws is a recent technique demonstrating high accuracy. The optimal treatment for spondylodiscitis is still a matter of debate. We performed a retrospective cohort study on surgical patients treated with pedicle screw/rod placement alone without the application of intervertebral cages. In this collective, we compare conventional open to a further minimalized percutaneous robot-assisted spinal instrumentation, avoiding a direct contact of implants and infectious focus. 90 records and CT scans of patients treated by dorsal transpedicular instrumentation of the infected segments with and without decompression and antibiotic therapy were analysed for clinical and radiological outcome parameters. 24 patients were treated by free-hand fluoroscopy-guided surgery (121 screws), and 66 patients were treated by percutaneous robot-assisted spinal instrumentation (341 screws). Accurate screw placement was confirmed in 90 % of robot-assisted and 73.5 % of free-hand placed screws. Implant revision due to misplacement was necessary in 4.95 % of the free-hand group compared to 0.58 % in the robot-assisted group. The average intraoperative X-ray exposure per case was 0.94 ± 1.04 min in the free-hand group vs. 0.4 ± 0.16 min in the percutaneous group (p = 0.000). Intraoperative adverse events were observed in 12.5 % of free-hand placed pedicle screws and 6.1 % of robot robot-assisted screws. The mean postoperative hospital stay in the free-hand group was 18.1 ± 12.9 days, and in percutaneous group, 13.8 ± 5.6 days (p = 0.012). This study demonstrates that the robot-guided insertion of pedicle screws is a safe and effective procedure in lumbar and thoracic spondylodiscitis with higher accuracy of implant placement, lower radiation dose, and decreased complication rates. Percutaneous spinal dorsal instrumentation seems to be sufficient to treat lumbar and thoracic spondylodiscitis.

  6. Adding navigation, artificial audition and vital sign monitoring capabilities to a telepresence mobile robot for remote home care applications.

    PubMed

    Laniel, Sebastien; Letourneau, Dominic; Labbe, Mathieu; Grondin, Francois; Polgar, Janice; Michaud, Francois

    2017-07-01

    A telepresence mobile robot is a remote-controlled, wheeled device with wireless internet connectivity for bidirectional audio, video and data transmission. In health care, a telepresence robot could be used to have a clinician or a caregiver assist seniors in their homes without having to travel to these locations. Many mobile telepresence robotic platforms have recently been introduced on the market, bringing mobility to telecommunication and vital sign monitoring at reasonable costs. What is missing for making them effective remote telepresence systems for home care assistance are capabilities specifically needed to assist the remote operator in controlling the robot and perceiving the environment through the robot's sensors or, in other words, minimizing cognitive load and maximizing situation awareness. This paper describes our approach adding navigation, artificial audition and vital sign monitoring capabilities to a commercially available telepresence mobile robot. This requires the use of a robot control architecture to integrate the autonomous and teleoperation capabilities of the platform.

  7. Stage-directed individualized therapy in esophageal cancer.

    PubMed

    Goense, Lucas; van Rossum, Peter S N; Kandioler, Daniela; Ruurda, Jelle P; Goh, Khean-Lee; Luyer, Misha D; Krasna, Mark J; van Hillegersberg, Richard

    2016-10-01

    Esophageal cancer is the eighth most common cancer worldwide, and the incidence of esophageal carcinoma is rapidly increasing. With the advent of new staging and treatment techniques, esophageal cancer can now be managed through various strategies. A good understanding of the advances and limitations of new staging techniques and how these can guide in individualizing treatment is important to improve outcomes for esophageal cancer patients. This paper outlines the recent progress in staging and treatment of esophageal cancer, with particularly attention to endoscopic techniques for early-stage esophageal cancer, multimodality treatment for locally advanced esophageal cancer, assessment of response to neoadjuvant treatment, and the role of cervical lymph node dissection. Furthermore, advances in robot-assisted surgical techniques and postoperative recovery protocols that may further improve outcomes after esophagectomy are discussed. © 2016 The Authors. Annals of the New York Academy of Sciences published by Wiley Periodicals Inc. on behalf of The New York Academy of Sciences.

  8. Functional assessment and performance evaluation for assistive robotic manipulators: Literature review.

    PubMed

    Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A

    2013-07-01

    The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System - PITTCat. Twenty relevant studies were identified. Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators.

  9. The place of robotics in gynecologic surgery.

    PubMed

    Quemener, J; Boulanger, L; Rubod, C; Cosson, M; Vinatier, D; Collinet, P

    2012-10-01

    Robot-assisted laparoscopic gynecologic surgery has undergone widespread development in recent years. The surgical literature on this subject continues to grow. The goal of this article is to summarize the principal indications for robotic assistance in gynecologic surgery and to offer a general overview of the principal articles dealing with robotic surgery for both benign and malignant disease. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  10. The Leipzig experience with robotic valve surgery.

    PubMed

    Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W

    2000-01-01

    The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

  11. [Robot-aided training in rehabilitation].

    PubMed

    Hachisuka, Kenji

    2010-02-01

    Recently, new training techniques that involve the use of robots have been used in the rehabilitation of patients with hemiplegia and paraplegia. Robots used for training the arm include the MIT-MANUS, Arm Trainer, mirror-image motion enabler (MIME) robot, and the assisted rehabilitation and measurement (ARM) Guide. Robots that are used for lower-limb training are the Rehabot, Gait Trainer, Lokomat, LOPES Exoskeleton Robot, and Gait Assist Robot. Robot-aided therapy has enabled the functional training of the arm and the lower limbs in an effective, easy, and comfortable manner. Therefore, with this type of therapy, the patients can repeatedly undergo sufficient and accurate training for a prolonged period. However, evidence of the benefits of robot-aided training has not yet been established.

  12. Robot-Assisted Training for People With Spinal Cord Injury: A Meta-Analysis.

    PubMed

    Cheung, Eddy Y Y; Ng, Thomas K W; Yu, Kevin K K; Kwan, Rachel L C; Cheing, Gladys L Y

    2017-11-01

    To investigate the effects of robot-assisted training on the recovery of people with spinal cord injury (SCI). Randomized controlled trials (RCTs) or quasi-RCTs involving people with SCI that compared robot-assisted upper limbs or lower limbs training with a control of other treatment approach or no treatment. We included studies involving people with complete or incomplete SCIs. We searched MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials (Cochrane Library), and Embase to August 2016. Bibliographies of relevant articles on the effect of body-weight-supported treadmill training on subjects with SCI were screened to avoid missing relevant articles from the search of databases. All kinds of objective assessments concerning physical ability, mobility, and/or functional ability were included. Assessments could be clinical tests (ie, 6-minute walk test, FIM) or laboratory tests (ie, gait analysis). Subjective outcome measures were excluded from this review. Eleven RCT studies involving 443 subjects were included in the study. Meta-analysis was performed on the included studies. Walking independence (3.73; 95% confidence interval [CI], -4.92 to -2.53; P<.00001; I 2 =38%) and endurance (53.32m; 95% CI, -73.15 to -33.48; P<.00001; I 2 =0%) were found to have better improvement in robot-assisted training groups. Lower limb robot-assisted training was also found to be as effective as other types of body-weight-supported training. There is a lack of upper limb robot-assisted training studies; therefore, performing a meta-analysis was not possible. Robot-assisted training is an adjunct therapy for physical and functional recovery for patients with SCI. Future high-quality studies are warranted to investigate the effects of robot-assisted training on functional and cardiopulmonary recovery of patients with SCI. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Tool actuation and force feedback on robot-assisted microsurgery system

    NASA Technical Reports Server (NTRS)

    Das, Hari (Inventor); Ohm, Tim R. (Inventor); Boswell, Curtis D. (Inventor); Steele, Robert D. (Inventor)

    2002-01-01

    An input control device with force sensors is configured to sense hand movements of a surgeon performing a robot-assisted microsurgery. The sensed hand movements actuate a mechanically decoupled robot manipulator. A microsurgical manipulator, attached to the robot manipulator, is activated to move small objects and perform microsurgical tasks. A force-feedback element coupled to the robot manipulator and the input control device provides the input control device with an amplified sense of touch in the microsurgical manipulator.

  14. Development of a Wearable Assist Robot for Walk Rehabilitation After Knee Arthroplasty Surgery

    NASA Astrophysics Data System (ADS)

    Terada, H.; Zhu, Y.; Horiguchi, K.; Nakamura, M.; Takahashi, R.

    In Japan, it is popular that the disease knee joints will be replaced to artificial joints by surgery. And we have to assist so many patients for walk rehabilitation. So, the wearable assist robot has been developed. This robot includes the knee motion assist mechanism and the hip joint support mechanism. Especially, the knee motion assist mechanism consists of a non-circular gear and grooved cams. This mechanism rotates and slides simultaneously, which has two degree-of-freedom. Also, the hip joint support mechanism consists of a hip brace and a ball-joint. This mechanism can avoid motion constraints which are the internal or external rotation and the adduction or abduction. Then, the control algorithm, which considers an assisting timing for the walk rehabilitation, has been proposed. A sensing system of a walk state for this control system uses a heel contacts sensor and knee and hip joint rotation angle sensors. Also, the prototype robot has been tested. And it is confirmed that the assisting system is useful.

  15. Robot Tracking of Human Subjects in Field Environments

    NASA Technical Reports Server (NTRS)

    Graham, Jeffrey; Shillcutt, Kimberly

    2003-01-01

    Future planetary exploration will involve both humans and robots. Understanding and improving their interaction is a main focus of research in the Intelligent Systems Branch at NASA's Johnson Space Center. By teaming intelligent robots with astronauts on surface extra-vehicular activities (EVAs), safety and productivity can be improved. The EVA Robotic Assistant (ERA) project was established to study the issues of human-robot teams, to develop a testbed robot to assist space-suited humans in exploration tasks, and to experimentally determine the effectiveness of an EVA assistant robot. A companion paper discusses the ERA project in general, its history starting with ASRO (Astronaut-Rover project), and the results of recent field tests in Arizona. This paper focuses on one aspect of the research, robot tracking, in greater detail: the software architecture and algorithms. The ERA robot is capable of moving towards and/or continuously following mobile or stationary targets or sequences of targets. The contributions made by this research include how the low-level pose data is assembled, normalized and communicated, how the tracking algorithm was generalized and implemented, and qualitative performance reports from recent field tests.

  16. The University of Chicago technique of complete intracorporeal pediatric robotic-assisted laparoscopic augmentation ileocystoplasty and Mitrofanoff appendicovesicostomy.

    PubMed

    Gundeti, Mohan S; Acharya, Sujeet S; Zagaja, Gregory P

    2009-06-01

    We present the University of Chicago technique for complete intracorporeal robotic-assisted laparoscopic augmentation ileocystoplasty and Mitrofanoff appendicovesicostomy. The operative steps of the open procedure were replicated laparoscopically using robotic assistance. Initially, five transperitoneal laparoscopic ports are placed prior to docking the da Vinci S robotic system. A 20 cm ileal segment is isolated, and the gastrointestinal anastomosis is performed in an end-to-end fashion using intracorporeal suturing. The appendix is anastomosed to the right posterior wall of the bladder over an 8F feeding tube in an extravesical fashion. Then, the bladder is incised in a coronal plane, and the simple detubularized ileal on-lay patch is anastomosed to the posterior and anterior walls of the bladder. A suprapubic catheter and pelvic drain are placed. Finally, the Mitrofanoff stoma is then fashioned. Cystography is done at 4 weeks postoperatively. This report suggests that robotic-assisted ileocystoplasty and appendicovesicostomy is feasible. A reasonable outcome with early recovery, resumption of normal activities, and excellent cosmesis can be achieved in select patients. A large case series, however, is necessary to determine whether a robotic-assisted approach provides any significant advantages over conventional open procedures.

  17. The First Korean Experience of Telemanipulative Robot-Assisted Laparoscopic Cholecystectomy Using the da Vinci System

    PubMed Central

    Kang, Chang Moo; Chi, Hoon Sang; Hyeung, Woo Jin; Kim, Kyung Sik; Choi, Jin Sub; Kim, Byong Ro

    2007-01-01

    With the advancement of laparoscopic instruments and computer sciences, complex surgical procedures are expected to be safely performed by robot assisted telemanipulative laparoscopic surgery. The da Vinci system (Intuitive Surgical, Mountain View, CA, USA) became available at the many surgical fields. The wrist like movements of the instrument's tip, as well as 3-dimensional vision, could be expected to facilitate more complex laparoscopic procedure. Here, we present the first Korean experience of da Vinci robotic assisted laparoscopic cholecystectomy and discuss the introduction and perspectives of this robotic system. PMID:17594166

  18. Walking with robot assistance: the influence of body weight support on the trunk and pelvis kinematics.

    PubMed

    Swinnen, Eva; Baeyens, Jean-Pierre; Knaepen, Kristel; Michielsen, Marc; Hens, Gerrit; Clijsen, Ron; Goossens, Maggie; Buyl, Ronald; Meeusen, Romain; Kerckhofs, Eric

    2015-05-01

    The goal was to assess in healthy participants the three-dimensional kinematics of the pelvis and the trunk during robot-assisted treadmill walking (RATW) at 0%, 30% and 50% body weight support (BWS), compared with treadmill walking (TW). 18 healthy participants walked (2 kmph) on a treadmill with and without robot assistance (Lokomat; 60% guidance force; 0%, 30% and 50% BWS). After an acclimatisation period (four minutes), trunk and pelvis kinematics were registered in each condition (Polhemus Liberty [240 Hz]). The results were analysed using a repeated measures analysis of variance with Bonferroni correction, with the level of suspension as within-subject factor. During RATW with BWS, there were significantly (1) smaller antero-posterior and lateral translations of the trunk and the pelvis; (2) smaller antero-posterior flexion and axial rotation of the trunk; (3) larger lateral flexion of the trunk; and (4) larger antero-posterior tilting of the pelvis compared with TW. There are significant differences in trunk and pelvis kinematics in healthy persons during TW with and without robot assistance. These data are relevant in gait rehabilitation, relating to normal balance regulation. Additional research is recommended to further assess the influence of robot assistance on human gait. The trunk and pelvis moves in a different way during walking with robot assistance. The data suggest that the change in movement is due to the robot device and the harness of the suspension system more than due to the level of suspension itself.

  19. Prospective Clinical Trial of Robotically Assisted Endoscopic Coronary Grafting With 1-Year Follow-Up

    PubMed Central

    Prasad, Sunil M.; Ducko, Christopher T.; Stephenson, Edward R.; Chambers, Charles E.; Damiano, Ralph J.

    2001-01-01

    Objective To follow up in prospective fashion patients with coronary artery anastomoses completed endoscopically with robotic assistance. The robotic system was evaluated for safety and its effectiveness in completing microsurgical coronary anastomoses. Summary Background Data Recently there has been an interest in using robotics and computers to enhance the surgeon’s ability to perform endoscopic cardiac surgery. This interest has stemmed from the rapid advancement of technology and the desire to make cardiac surgery less invasive. Using traditional endoscopic instruments, it has not been possible to perform coronary surgery. Methods Nineteen patients underwent robotically assisted endoscopic coronary artery bypass grafting of the left internal thoracic artery (LITA) to the left anterior descending artery (LAD). Two robotic instruments and one endoscopic camera were placed through three 5-mm ports. A robotic system was used to construct the LITA–LAD anastomosis. All other required grafts were completed by conventional techniques. Results Seventeen LITA–LAD grafts (89%) had adequate intraoperative flow. The mean LITA–LAD graft flow was 38.5 ± 5 mL/min. At 8 weeks, LITA–LAD grafts were assessed by angiography and showed 100% patency with thrombolysis in myocardial infarction (TIMI) I flow. At a mean follow-up of 17 ± 4.2 months, all patients were NYHA class I and there were no adverse cardiac events. Conclusions The results from the first prospective clinical trial of robotically assisted endoscopic coronary bypass surgery in the United States showed favorable short-term outcomes with no adverse events. Robotic assistance is an enabling technology allowing the performance of endoscopic coronary anastomoses. PMID:11371730

  20. Transoral robotic-assisted laryngeal cleft repair in the pediatric patient.

    PubMed

    Leonardis, Rachel L; Duvvuri, Umamaheswar; Mehta, Deepak

    2014-09-01

    To assess the feasibility of performing robotic-assisted laryngeal cleft repair in the pediatric population. Retrospective chart review at a tertiary academic children's hospital. All patients underwent transoral robotic-assisted laryngeal cleft repair from March 2011 to June 2013. Demographics, robotic docking time, operative time, and postoperative course and swallowing function were collected and analyzed. Five children, three male and two female, underwent successful transoral robotic-assisted laryngeal cleft repair for closure of a type I laryngeal cleft. Mean age at time of surgery was 21.6 months (standard deviation 6.1 months; range, 15-29 months). From case 1 to case 5, robotic docking time (18-10 minutes), robotic operative time (102-36 minutes), and total operating room time (173-105 minutes) decreased. There were no complications with time until extubation (range, 2-3 days), length of intensive care unit stay (range, 3-4 days), and total hospital stay (range, 3-5 days) within acceptable range following laryngeal cleft repair. Modified barium swallow (two patients) or fiberoptic endoscopic evaluation of swallowing (three patients) was performed postoperatively, with all patients showing complete resolution of penetration and aspiration. In addition, all patients experienced subjective resolution of dysphagia and/or choking with feeds postoperatively. Transoral robotic-assisted laryngeal cleft repair may offer specific advantages over a traditional endoscopic approach. In our experience, the procedure was well tolerated and associated with definitive surgical cure in all patients. The scope of robotic technology continually expands and should be considered a feasible tool at an institution-based level. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  1. System for robot-assisted real-time laparoscopic ultrasound elastography

    NASA Astrophysics Data System (ADS)

    Billings, Seth; Deshmukh, Nishikant; Kang, Hyun Jae; Taylor, Russell; Boctor, Emad M.

    2012-02-01

    Surgical robots provide many advantages for surgery, including minimal invasiveness, precise motion, high dexterity, and crisp stereovision. One limitation of current robotic procedures, compared to open surgery, is the loss of haptic information for such purposes as palpation, which can be very important in minimally invasive tumor resection. Numerous studies have reported the use of real-time ultrasound elastography, in conjunction with conventional B-mode ultrasound, to differentiate malignant from benign lesions. Several groups (including our own) have reported integration of ultrasound with the da Vinci robot, and ultrasound elastography is a very promising image guidance method for robotassisted procedures that will further enable the role of robots in interventions where precise knowledge of sub-surface anatomical features is crucial. We present a novel robot-assisted real-time ultrasound elastography system for minimally invasive robot-assisted interventions. Our system combines a da Vinci surgical robot with a non-clinical experimental software interface, a robotically articulated laparoscopic ultrasound probe, and our GPU-based elastography system. Elasticity and B-mode ultrasound images are displayed as picture-in-picture overlays in the da Vinci console. Our system minimizes dependence on human performance factors by incorporating computer-assisted motion control that automatically generates the tissue palpation required for elastography imaging, while leaving high-level control in the hands of the user. In addition to ensuring consistent strain imaging, the elastography assistance mode avoids the cognitive burden of tedious manual palpation. Preliminary tests of the system with an elasticity phantom demonstrate the ability to differentiate simulated lesions of varied stiffness and to clearly delineate lesion boundaries.

  2. Robotic assistance improves intracorporeal suturing performance and safety in the operating room while decreasing operator workload.

    PubMed

    Stefanidis, Dimitrios; Wang, Fikre; Korndorffer, James R; Dunne, J Bruce; Scott, Daniel J

    2010-02-01

    Intracorporeal suturing is one of the most difficult laparoscopic tasks. The purpose of this study was to assess the impact of robotic assistance on novice suturing performance, safety, and workload in the operating room. Medical students (n = 34), without prior laparoscopic suturing experience, were enrolled in an Institutional Review Board-approved, randomized protocol. After viewing an instructional video, subjects were tested in intracorporeal suturing on two identical, live, porcine Nissen fundoplication models; they placed three gastro-gastric sutures using conventional laparoscopic instruments in one model and using robotic assistance (da Vinci) in the other, in random order. Each knot was objectively scored based on time, accuracy, and security. Injuries to surrounding structures were recorded. Workload was assessed using the validated National Aeronautics and Space Administration (NASA) task load index (TLX) questionnaire, which measures the subjects' self-reported performance, effort, frustration, and mental, physical, and temporal demands of the task. Analysis was by paired t-test; p < 0.05 was considered significant. Compared with laparoscopy, robotic assistance enabled subjects to suture faster (595 +/- 22 s versus 459 +/- 137 s, respectively; p < 0.001), achieve higher overall scores (0 +/- 1 versus 95 +/- 128, respectively; p < 0.001), and commit fewer errors per knot (1.15 +/- 1.35 versus 0.05 +/- 0.26, respectively; p < 0.001). Subjects' overall score did not improve between the first and third attempt for laparoscopic suturing (0 +/- 0 versus 0 +/- 0; p = NS) but improved significantly for robotic suturing (49 +/- 100 versus 141 +/- 152; p < 0.001). Moreover, subjects indicated on the NASA-TLX scale that the task was more difficult to perform with laparoscopic instruments compared with robotic assistance (99 +/- 15 versus 57 +/- 23; p < 0.001). Compared with standard laparoscopy, robotic assistance significantly improved intracorporeal suturing performance and safety of novices in the operating room while decreasing their workload. Moreover, the robot significantly shortened the learning curve of this difficult task. Further study is needed to assess the value of robotic assistance for experienced surgeons, and validated robotic training curricula need to be developed.

  3. HiMoP: A three-component architecture to create more human-acceptable social-assistive robots : Motivational architecture for assistive robots.

    PubMed

    Rodríguez-Lera, Francisco J; Matellán-Olivera, Vicente; Conde-González, Miguel Á; Martín-Rico, Francisco

    2018-05-01

    Generation of autonomous behavior for robots is a general unsolved problem. Users perceive robots as repetitive tools that do not respond to dynamic situations. This research deals with the generation of natural behaviors in assistive service robots for dynamic domestic environments, particularly, a motivational-oriented cognitive architecture to generate more natural behaviors in autonomous robots. The proposed architecture, called HiMoP, is based on three elements: a Hierarchy of needs to define robot drives; a set of Motivational variables connected to robot needs; and a Pool of finite-state machines to run robot behaviors. The first element is inspired in Alderfer's hierarchy of needs, which specifies the variables defined in the motivational component. The pool of finite-state machine implements the available robot actions, and those actions are dynamically selected taking into account the motivational variables and the external stimuli. Thus, the robot is able to exhibit different behaviors even under similar conditions. A customized version of the "Speech Recognition and Audio Detection Test," proposed by the RoboCup Federation, has been used to illustrate how the architecture works and how it dynamically adapts and activates robots behaviors taking into account internal variables and external stimuli.

  4. Are All Hands-On Activities Equally Effective? Effect of Using Plastic Models, Organ Dissections, and Virtual Dissections on Student Learning and Perceptions

    ERIC Educational Resources Information Center

    Lombardi, Sara A.; Hicks, Reimi E.; Thompson, Katerina V.; Marbach-Ad, Gili

    2014-01-01

    This study investigated the impact of three commonly used cardiovascular model-assisted activities on student learning and student attitudes and perspectives about science. College students enrolled in a Human Anatomy and Physiology course were randomly assigned to one of three experimental groups (organ dissections, virtual dissections, or…

  5. A Human-Robot Co-Manipulation Approach Based on Human Sensorimotor Information.

    PubMed

    Peternel, Luka; Tsagarakis, Nikos; Ajoudani, Arash

    2017-07-01

    This paper aims to improve the interaction and coordination between the human and the robot in cooperative execution of complex, powerful, and dynamic tasks. We propose a novel approach that integrates online information about the human motor function and manipulability properties into the hybrid controller of the assistive robot. Through this human-in-the-loop framework, the robot can adapt to the human motor behavior and provide the appropriate assistive response in different phases of the cooperative task. We experimentally evaluate the proposed approach in two human-robot co-manipulation tasks that require specific complementary behavior from the two agents. Results suggest that the proposed technique, which relies on a minimum degree of task-level pre-programming, can achieve an enhanced physical human-robot interaction performance and deliver appropriate level of assistance to the human operator.

  6. Role of robotics in managing mesh and suture complications of prior pelvic organ prolapse surgery.

    PubMed

    Wilkinson, Michael N; O'Sullivan, Orfhlaith E; O'Reilly, Barry A

    2017-03-01

    Robotic surgery is proving essential in providing a minimally invasive approach to complex urogynaecological cases. This video highlights the diversity and complexity of cases performed using the robot-assisted approach. The robot-assisted approach was utilised for excellent effect in two complex urogynaecological cases. In the first case the entire left arm of an intravesically placed TVT was removed using a combined vaginal and robotic approach. The second case involved removing four paravaginal sutures, one of which breeched the bladder and was encrusted with calculus. These were placed during a laparoscopic paravaginal repair 2 years previously. She had a concomitant vaginal hysterectomy, Mc Calls culdoplasty and anterior wall repair. The robot-assisted approach allows for excellent access to the pelvis and retropubic space facilitating the surgical management of complex urogynaecology cases.

  7. Dissecting Vertebral Artery Aneurysm Presenting Regrowth After Stent-Assisted Coil Embolization in Acute Stage.

    PubMed

    Hijikata, Takamichi; Baba, Eiichi; Shirokane, Kazutaka; Tsuchiya, Atsushi; Nomura, Motohiro

    2018-06-01

    For a case of dissecting vertebral artery aneurysm (DVAA) in a dominant vertebral artery (VA) or posterior inferior cerebellar artery (PICA)-involving lesion, stent-assisted coil embolization (SACE) is an effective technique to preserve blood flow of the VA. A 41-year-old man presented with subarachnoid hemorrhage. Angiography demonstrated DVAA on the left VA just distal to the PICA, and the right VA was thinner than the left. For this case, SACE was performed to preserve the left VA and PICA. On the 10th day, angiography showed recurrence of the dissection. The dissected portion had thickened and extended to both distal and proximal sides involving the PICA origin and proximal portion to the PICA. A second endovascular embolization was performed and the recurrent dissecting aneurysm was embolized including the main VA cavity. In cases of DVAA, there is a possibility of recurrence after SACE, if a dissecting cavity remains unembolized. Therefore, total embolization is necessary under close observation from multiple angles, including the down-the-barrel view.

  8. Towards using musculoskeletal models for intelligent control of physically assistive robots.

    PubMed

    Carmichael, Marc G; Liu, Dikai

    2011-01-01

    With the increasing number of robots being developed to physically assist humans in tasks such as rehabilitation and assistive living, more intelligent and personalized control systems are desired. In this paper we propose the use of a musculoskeletal model to estimate the strength of the user, from which information can be utilized to improve control schemes in which robots physically assist humans. An optimization model is developed utilizing a musculoskeletal model to estimate human strength in a specified dynamic state. Results of this optimization as well as methods of using it to observe muscle-based weaknesses in task space are presented. Lastly potential methods and problems in incorporating this model into a robot control system are discussed.

  9. Invariant ankle moment patterns when walking with and without a robotic ankle exoskeleton.

    PubMed

    Kao, Pei-Chun; Lewis, Cara L; Ferris, Daniel P

    2010-01-19

    To guide development of robotic lower limb exoskeletons, it is necessary to understand how humans adapt to powered assistance. The purposes of this study were to quantify joint moments while healthy subjects adapted to a robotic ankle exoskeleton and to determine if the period of motor adaptation is dependent on the magnitude of robotic assistance. The pneumatically powered ankle exoskeleton provided plantar flexor torque controlled by the wearer's soleus electromyography (EMG). Eleven naïve individuals completed two 30-min sessions walking on a split-belt instrumented treadmill at 1.25m/s while wearing the ankle exoskeleton. After two sessions of practice, subjects reduced their soleus EMG activation by approximately 36% and walked with total ankle moment patterns similar to their unassisted gait (r(2)=0.98+/-0.02, THSD, p>0.05). They had substantially different ankle kinematic patterns compared to their unassisted gait (r(2)=0.79+/-0.12, THSD, p<0.05). Not all of the subjects reached a steady-state gait pattern within the two sessions, in contrast to a previous study using a weaker robotic ankle exoskeleton (Gordon and Ferris, 2007). Our results strongly suggest that humans aim for similar joint moment patterns when walking with robotic assistance rather than similar kinematic patterns. In addition, greater robotic assistance provided during initial use results in a longer adaptation process than lesser robotic assistance. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. Robotic versus laparoscopic proctectomy for rectal cancer: a meta-analysis.

    PubMed

    Memon, Sameer; Heriot, Alexander G; Murphy, Declan G; Bressel, Mathias; Lynch, A Craig

    2012-07-01

    Robot-assisted laparoscopic surgery is being performed more frequently for the minimally invasive management of rectal cancer. The objective of this meta-analysis was to compare the clinical and oncologic safety and efficacy of robot-assisted versus conventional laparoscopic surgery. A search of the Medline and Embase databases was performed for studies that compared clinical or oncologic outcomes of conventional laparoscopic proctectomy with robot-assisted laparoscopic proctectomy for rectal cancer. The methodological quality of the selected studies was critically assessed to identify studies suitable for inclusion. Meta-analysis was performed by a random effects model and analyzed by Review Manager. Clinical outcomes evaluated were conversion rates, operation times, length of hospital stay, and complications. Oncologic outcomes evaluated were circumferential margin status, number of lymph nodes collected, and distal resection margin lengths. Eight comparative studies were assessed for quality, and seven studies were included in the meta-analysis. Two studies were matched case-control studies, and five were unmatched. A total of 353 robot-assisted laparoscopic surgery proctectomy cases and 401 conventional laparoscopic surgery proctectomy cases were analyzed. Robotic surgery was associated with a significantly lower conversion rate (P=0.03; 95% confidence interval 1-12). There was no difference in complications, circumferential margin involvement, distal resection margin, lymph node yield, or hospital stay (P=NS). Robot-assisted surgery decreased the conversion rate compared to conventional laparoscopic surgery. Other clinical outcomes and oncologic outcomes were equivalent. The benefits of robotic rectal cancer surgery may differ between population groups.

  11. Multidisciplinary approach for developing a new robotic system for domiciliary assistance to elderly people.

    PubMed

    Cavallo, F; Aquilano, M; Bonaccorsi, M; Mannari, I; Carrozza, M C; Dario, P

    2011-01-01

    This paper aims to show the effectiveness of a (inter / multi)disciplinary team, based on the technology developers, elderly care organizations, and designers, in developing the ASTRO robotic system for domiciliary assistance to elderly people. The main issues presented in this work concern the improvement of robot's behavior by means of a smart sensor network able to share information with the robot for localization and navigation, and the design of the robot's appearance and functionalities by means of a substantial analysis of users' requirements and attitude to robotic technology to improve acceptability and usability.

  12. Development of next-generation mapping populations: Multi-parent Advanced Generation Inter-Cross (MAGIC) and Marker-Assisted Recurrent Selection (MARS) populations in peanut

    USDA-ARS?s Scientific Manuscript database

    Generation Inter-Cross (MAGIC) and Marker-Assisted Recurrent Selection (MARS) have been proposed and used in many crops to dissect complex traits or QTL. MAGIC allows for dissecting genomic structure, and for improving breeding populations by integrating multiple alleles from different parents. MAR...

  13. An Exoskeleton Robot for Human Forearm and Wrist Motion Assist

    NASA Astrophysics Data System (ADS)

    Ranathunga Arachchilage Ruwan Chandra Gopura; Kiguchi, Kazuo

    The exoskeleton robot is worn by the human operator as an orthotic device. Its joints and links correspond to those of the human body. The same system operated in different modes can be used for different fundamental applications; a human-amplifier, haptic interface, rehabilitation device and assistive device sharing a portion of the external load with the operator. We have been developing exoskeleton robots for assisting the motion of physically weak individuals such as elderly or slightly disabled in daily life. In this paper, we propose a three degree of freedom (3DOF) exoskeleton robot (W-EXOS) for the forearm pronation/ supination motion, wrist flexion/extension motion and ulnar/radial deviation. The paper describes the wrist anatomy toward the development of the exoskeleton robot, the hardware design of the exoskeleton robot and EMG-based control method. The skin surface electromyographic (EMG) signals of muscles in forearm of the exoskeletons' user and the hand force/forearm torque are used as input information for the controller. By applying the skin surface EMG signals as main input signals to the controller, automatic control of the robot can be realized without manipulating any other equipment. Fuzzy control method has been applied to realize the natural and flexible motion assist. Experiments have been performed to evaluate the proposed exoskeleton robot and its control method.

  14. Robot-assisted surgery: the future is here.

    PubMed

    Gerhardus, Diana

    2003-01-01

    According to L. Wiley Nifong, director of robotic surgery at East Carolina University's Brody School of Medicine, "Nationally, only one-fourth of the 15 million surgeries performed each year are done with small incisions or what doctors call 'minimally invasive surgery'." Robots could raise that number substantially (Stark 2002). Currently, healthcare organizations use robot technology for thoracic, abdominal, pelvic, and neurological surgical procedures. Minimally invasive surgery reduces the amount of inpatient hospital days, and the computer in the system filters any hand tremors a physician may have during the surgery. The use of robot-assisted surgery improves quality of care because the patient experiences less pain after the surgery. Robot-assisted surgery demonstrates definite advantages for the patient, physician, and hospital; however, healthcare organizations in the United States have yet to acquire the technology because of implementation costs and the lack of FDA (Food and Drug Administration) approval for using the technology for certain types of heart procedures. This article focuses on robot-assisted surgery advantages to patients, physicians, and hospitals as well as on the disadvantages to physicians. In addition, the article addresses implementation costs, which creates financial hurdles for most healthcare organizations; offers recommendations for administrators to embrace this technology for strategic positioning; and enumerates possible roles for robots in medicine.

  15. Experiments with an EVA Assistant Robot

    NASA Technical Reports Server (NTRS)

    Burridge, Robert R.; Graham, Jeffrey; Shillcutt, Kim; Hirsh, Robert; Kortenkamp, David

    2003-01-01

    Human missions to the Moon or Mars will likely be accompanied by many useful robots that will assist in all aspects of the mission, from construction to maintenance to surface exploration. Such robots might scout terrain, carry tools, take pictures, curate samples, or provide status information during a traverse. At NASA/JSC, the EVA Robotic Assistant (ERA) project has developed a robot testbed for exploring the issues of astronaut-robot interaction. Together with JSC's Advanced Spacesuit Lab, the ERA team has been developing robot capabilities and testing them with space-suited test subjects at planetary surface analog sites. In this paper, we describe the current state of the ERA testbed and two weeks of remote field tests in Arizona in September 2002. A number of teams with a broad range of interests participated in these experiments to explore different aspects of what must be done to develop a program for robotic assistance to surface EVA. Technologies explored in the field experiments included a fuel cell, new mobility platform and manipulator, novel software and communications infrastructure for multi-agent modeling and planning, a mobile science lab, an "InfoPak" for monitoring the spacesuit, and delayed satellite communication to a remote operations team. In this paper, we will describe this latest round of field tests in detail.

  16. Trunk robot rehabilitation training with active stepping reorganizes and enriches trunk motor cortex representations in spinal transected rats.

    PubMed

    Oza, Chintan S; Giszter, Simon F

    2015-05-06

    Trunk motor control is crucial for postural stability and propulsion after low thoracic spinal cord injury (SCI) in animals and humans. Robotic rehabilitation aimed at trunk shows promise in SCI animal models and patients. However, little is known about the effect of SCI and robot rehabilitation of trunk on cortical motor representations. We previously showed reorganization of trunk motor cortex after adult SCI. Non-stepping training also exacerbated some SCI-driven plastic changes. Here we examine effects of robot rehabilitation that promotes recovery of hindlimb weight support functions on trunk motor cortex representations. Adult rats spinal transected as neonates (NTX rats) at the T9/10 level significantly improve function with our robot rehabilitation paradigm, whereas treadmill-only trained do not. We used intracortical microstimulation to map motor cortex in two NTX groups: (1) treadmill trained (control group); and (2) robot-assisted treadmill trained (improved function group). We found significant robot rehabilitation-driven changes in motor cortex: (1) caudal trunk motor areas expanded; (2) trunk coactivation at cortex sites increased; (3) richness of trunk cortex motor representations, as examined by cumulative entropy and mutual information for different trunk representations, increased; (4) trunk motor representations in the cortex moved toward more normal topography; and (5) trunk and forelimb motor representations that SCI-driven plasticity and compensations had caused to overlap were segregated. We conclude that effective robot rehabilitation training induces significant reorganization of trunk motor cortex and partially reverses some plastic changes that may be adaptive in non-stepping paraplegia after SCI. Copyright © 2015 the authors 0270-6474/15/357174-16$15.00/0.

  17. Caregiver and social assistant robot for rehabilitation and coaching for the elderly.

    PubMed

    Pérez, P J; Garcia-Zapirain, B; Mendez-Zorrilla, A

    2015-01-01

    Socially assistive robotics (SAR) has been a major field of investigation during the last decade and, as it develops, the groups the technology can be applied to and all ways in which these can be assisted are rapidly increasing. The main objective is to design and develop a complete robotic agent, so that it performs physical and mental activities for elderly people to maintain their healthy life habits and, as a final result, improve their quality of life. LEGO Mindstorms NXT® robot's unique capacity for adaptability and engaging its users to develop coaching activities and assistive rehabilitation for the elderly. Such activities will aim to enhance healthy habits and provide training in physical and mental rehabilitation. The robot is attached to an iPod Touch that acts as its interface. The robot has been tested by a voluntary group of residents, also from that retirement home. Results in the variables of the questionnaire show scores above 4 points out of 5 for all the categories. Based on the tests, an easy to use Robot is prepared to deliver basic coaching for physical activities as proposed by the client, the staff of La Misericordia, who confirmed their satisfaction regarding this aspect.

  18. Review of control strategies for robotic movement training after neurologic injury.

    PubMed

    Marchal-Crespo, Laura; Reinkensmeyer, David J

    2009-06-16

    There is increasing interest in using robotic devices to assist in movement training following neurologic injuries such as stroke and spinal cord injury. This paper reviews control strategies for robotic therapy devices. Several categories of strategies have been proposed, including, assistive, challenge-based, haptic simulation, and coaching. The greatest amount of work has been done on developing assistive strategies, and thus the majority of this review summarizes techniques for implementing assistive strategies, including impedance-, counterbalance-, and EMG- based controllers, as well as adaptive controllers that modify control parameters based on ongoing participant performance. Clinical evidence regarding the relative effectiveness of different types of robotic therapy controllers is limited, but there is initial evidence that some control strategies are more effective than others. It is also now apparent there may be mechanisms by which some robotic control approaches might actually decrease the recovery possible with comparable, non-robotic forms of training. In future research, there is a need for head-to-head comparison of control algorithms in randomized, controlled clinical trials, and for improved models of human motor recovery to provide a more rational framework for designing robotic therapy control strategies.

  19. Review of control strategies for robotic movement training after neurologic injury

    PubMed Central

    Marchal-Crespo, Laura; Reinkensmeyer, David J

    2009-01-01

    There is increasing interest in using robotic devices to assist in movement training following neurologic injuries such as stroke and spinal cord injury. This paper reviews control strategies for robotic therapy devices. Several categories of strategies have been proposed, including, assistive, challenge-based, haptic simulation, and coaching. The greatest amount of work has been done on developing assistive strategies, and thus the majority of this review summarizes techniques for implementing assistive strategies, including impedance-, counterbalance-, and EMG- based controllers, as well as adaptive controllers that modify control parameters based on ongoing participant performance. Clinical evidence regarding the relative effectiveness of different types of robotic therapy controllers is limited, but there is initial evidence that some control strategies are more effective than others. It is also now apparent there may be mechanisms by which some robotic control approaches might actually decrease the recovery possible with comparable, non-robotic forms of training. In future research, there is a need for head-to-head comparison of control algorithms in randomized, controlled clinical trials, and for improved models of human motor recovery to provide a more rational framework for designing robotic therapy control strategies. PMID:19531254

  20. Robot-assisted total laparoscopic hysterectomy in obese and morbidly obese women.

    PubMed

    Rebeles, Sonia A; Muntz, Howard G; Wieneke-Broghammer, Carrie; Vason, Emily S; McGonigle, Kathryn F

    2009-10-01

    Total laparoscopic hysterectomy (TLH) in obese patients is challenging. We sought to evaluate whether total laparoscopic hysterectomies using the da Vinci robotic system in obese patients, in comparison with non-obese patients, is a reasonable surgical approach. One-hundred consecutive robot-assisted TLHs were performed over a 17-month period. Obesity was not a contraindication to robotic surgery, assuming adequate respiratory function to tolerate Trendelenburg position and, for cancer cases, a small enough uterus to allow vaginal extraction without morcellation. Data were prospectively collected on patient characteristics, total operative time, hysterectomy time, estimated blood loss, length of stay, and complications. Outcomes with non-obese and obese women were compared. The median age, weight, and BMI of the 100 patients who underwent robot-assisted TLH was 57.6 years (30.0-90.6), 82.1 kg (51.9-159.6), and 30.2 kg/m(2) (19.3-60.2), respectively. Fifty (50%) patients were obese (BMI ≥ 30); 22 patients were morbidly obese (BMI ≥ 40). There was no increase in complications (p = 0.56) or blood loss (p = 0.44) with increasing BMI. While increased BMI was associated with longer operative times (p = 0.05), median time increased by only 36 min when comparing non-obese and morbidly obese patients. Median length of stay was one day for all weight categories (p = 0.42). Robot-assisted TLH is feasible and can be safely performed in obese patients. More data are needed to compare robot-assisted TLH with other hysterectomy techniques in obese patients. Nonetheless, our results are encouraging. Robot-assisted total laparoscopic hysterectomy may be the preferred technique for appropriately selected obese patients.

  1. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis.

    PubMed

    Bagla, Sandeep; Smirniotopoulos, John; Orlando, Julie C; Piechowiak, Rachel

    2017-03-01

    Prostatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH. IRB-approved retrospective study of 40 consecutive patients 49-81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months. No significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm 2 vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred. Robotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  2. Robotic arm-assisted versus conventional unicompartmental knee arthroplasty: Exploratory secondary analysis of a randomised controlled trial.

    PubMed

    Blyth, M J G; Anthony, I; Rowe, P; Banger, M S; MacLean, A; Jones, B

    2017-11-01

    This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group. A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery. From the first post-operative day through to week 8 post-operatively, the median pain scores for the robotic arm-assisted group were 55.4% lower than those observed in the manual surgery group (p = 0.040).At three months post-operatively, the robotic arm-assisted group had better AKSS (robotic median 164, interquartile range (IQR) 131 to 178, manual median 143, IQR 132 to 166), although no difference was noted with the OKS.At one year post-operatively, the observed differences with the AKSS had narrowed from a median of 21 points to a median of seven points (p = 0.106) (robotic median 171, IQR 153 to 179; manual median 164, IQR 144 to 182). No difference was observed with the OKS, and almost half of each group reached the ceiling limit of the score (OKS > 43). A greater proportion of patients receiving robotic arm-assisted surgery improved their UCLA activity score.Binary logistic regression modelling for dichotomised outcome scores predicted the key factors associated with achieving excellent outcome on the AKSS: a pre-operative activity level > 5 on the UCLA activity score and use of robotic-arm surgery. For the same regression modelling, factors associated with a poor outcome were manual surgery and pre-operative depression. Robotic arm-assisted surgery results in improved early pain scores and early function scores in some patient-reported outcomes measures, but no difference was observed at one year post-operatively. Although improved results favoured the robotic arm-assisted group in active patients (i.e. UCLA ⩾ 5), these do not withstand adjustment for multiple comparisons. Cite this article : M. J. G. Blyth, I. Anthony, P. Rowe, M. S. Banger, A. MacLean, B. Jones. Robotic arm-assisted versus conventional unicompartmental knee arthroplasty: Exploratory secondary analysis of a randomised controlled trial. Bone Joint Res 2017;6:631-639. DOI: 10.1302/2046-3758.611.BJR-2017-0060.R1. © 2017 Blyth et al.

  3. Applying a soft-robotic glove as assistive device and training tool with games to support hand function after stroke: Preliminary results on feasibility and potential clinical impact.

    PubMed

    Prange-Lasonder, Gerdienke B; Radder, Bob; Kottink, Anke I R; Melendez-Calderon, Alejandro; Buurke, Jaap H; Rietman, Johan S

    2017-07-01

    Recent technological developments regarding wearable soft-robotic devices extend beyond the current application of rehabilitation robotics and enable unobtrusive support of the arms and hands during daily activities. In this light, the HandinMind (HiM) system was developed, comprising a soft-robotic, grip supporting glove with an added computer gaming environment. The present study aims to gain first insight into the feasibility of clinical application of the HiM system and its potential impact. In order to do so, both the direct influence of the HiM system on hand function as assistive device and its therapeutic potential, of either assistive or therapeutic use, were explored. A pilot randomized clinical trial was combined with a cross-sectional measurement (comparing performance with and without glove) at baseline in 5 chronic stroke patients, to investigate both the direct assistive and potential therapeutic effects of the HiM system. Extended use of the soft-robotic glove as assistive device at home or with dedicated gaming exercises in a clinical setting was applicable and feasible. A positive assistive effect of the soft-robotic glove was proposed for pinch strength and functional task performance 'lifting full cans' in most of the five participants. A potential therapeutic impact was suggested with predominantly improved hand strength in both participants with assistive use, and faster functional task performance in both participants with therapeutic application.

  4. Robots for use in autism research.

    PubMed

    Scassellati, Brian; Admoni, Henny; Matarić, Maja

    2012-01-01

    Autism spectrum disorders are a group of lifelong disabilities that affect people's ability to communicate and to understand social cues. Research into applying robots as therapy tools has shown that robots seem to improve engagement and elicit novel social behaviors from people (particularly children and teenagers) with autism. Robot therapy for autism has been explored as one of the first application domains in the field of socially assistive robotics (SAR), which aims to develop robots that assist people with special needs through social interactions. In this review, we discuss the past decade's work in SAR systems designed for autism therapy by analyzing robot design decisions, human-robot interactions, and system evaluations. We conclude by discussing challenges and future trends for this young but rapidly developing research area.

  5. Biomechanical effects of robot assisted walking on knee joint kinematics and muscle activation pattern.

    PubMed

    Thangavel, Pavithra; Vidhya, S; Li, Junhua; Chew, Effie; Bezerianos, Anastasios; Yu, Haoyong

    2017-07-01

    Since manual rehabilitation therapy can be taxing for both the patient and the physiotherapist, a gait rehabilitation robot has been built to reduce the physical strain and increase the efficacy of the rehabilitation therapy. The prototype of the gait rehabilitation robot is designed to provide assistance while walking for patients with abnormal gait pattern and it can also be used for rehabilitation therapy to restore an individual's normal gait pattern by aiding motor recovery. The Gait Rehabilitation Robot uses gait event based synchronization, which enables the exoskeleton to provide synchronous assistance during walking that aims to reduce the lower-limb muscle activation. This study emphasizes on the biomechanical effects of assisted walking on the lower limb by analyzing the EMG signal, knee joint kinematics data that was collected from the right leg during the various experimental conditions. The analysis of the measured data shows an improved knee joint trajectory and reduction in muscle activity with assistance. The result of this study does not only assess the functionality of the exoskeleton but also provides a profound understanding of the human-robot interaction by studying the effects of assistance on the lower limb.

  6. Impact of metabolic syndrome on early recovery of continence after robot-assisted radical prostatectomy.

    PubMed

    Nishikawa, Masatomo; Watanabe, Hiromitsu; Kurahashi, Toshifumi

    2017-09-01

    To evaluate the impact of metabolic syndrome on the early recovery of urinary continence after robot-assisted radical prostatectomy. The present study included a total of 302 consecutive Japanese patients with clinically localized prostate cancer who underwent robot-assisted radical prostatectomy. In this study, postoperative urinary continence was defined as no leak or the use of a security pad. The continence status was assessed by interviews before and 1 and 3 months after robot-assisted radical prostatectomy. Metabolic syndrome was defined as follows: body mass index ≥25 kg/m 2 and two or more of the following: hypertension, diabetes mellitus and dyslipidemia. The effect of the presence of metabolic syndrome on the continence status of these patients was retrospectively examined. A total of 116 (38.4%) and 203 (67.2%) of the 302 patients were continent at 1 and 3 months after robot-assisted radical prostatectomy, respectively. A total of 31 (10.3%) patients were judged to have metabolic syndrome. Despite the operative time being longer in patients with metabolic syndrome, no significant differences were observed in the remaining preoperative, intraoperative or postoperative variables between patients with or without metabolic syndrome. On multivariate logistic regression analysis, metabolic syndrome and the duration of hospitalization were significantly correlated with the 1-month continence status. Similarly, metabolic syndrome and estimated blood loss during surgery were independent predictors of continence rates at 3 months after robot-assisted radical prostatectomy. These findings suggest that the presence of metabolic syndrome could have a significant impact on the early recovery of urinary continence after robot-assisted radical prostatectomy. © 2017 The Japanese Urological Association.

  7. Survivorship and patient satisfaction of robotic-assisted medial unicompartmental knee arthroplasty at a minimum two-year follow-up.

    PubMed

    Pearle, Andrew D; van der List, Jelle P; Lee, Lily; Coon, Thomas M; Borus, Todd A; Roche, Martin W

    2017-03-01

    Successful clinical outcomes following unicompartmental knee arthroplasty (UKA) depend on lower limb alignment, soft tissue balance and component positioning, which can be difficult to control using manual instrumentation. Although robotic-assisted surgery more reliably controls these surgical factors, studies assessing outcomes of robotic-assisted UKA are lacking. Therefore, a prospective multicenter study was performed to assess outcomes of robotic-assisted UKA. A total of 1007 consecutive patients (1135 knees) underwent robotic-assisted medial UKA surgery from six surgeons at separate institutions between March 2009 and December 2011. All patients received a fixed-bearing metal-backed onlay implant as tibial component. Each patient was contacted at minimum two-year follow-up and asked a series of five questions to determine survivorship and patient satisfaction. Worst-case scenario analysis was performed whereby all patients were considered as revision when they declined participation in the study. Data was collected for 797 patients (909 knees) with average follow-up of 29.6months (range: 22-52months). At 2.5-years of follow-up, 11 knees were reported as revised, which resulted in a survivorship of 98.8%. Thirty-five patients declined participation in the study yielding a worst-case survivorship of 96.0%. Of all patients without revision, 92% was either very satisfied or satisfied with their knee function. In this multicenter study, robotic-assisted UKA was found to have high survivorship and satisfaction rate at short-term follow-up. Prospective comparison studies with longer follow-up are necessary in order to compare survivorship and satisfaction rates of robotic-assisted UKA to conventional UKA and total knee arthroplasty. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Use of the holmium:YAG laser in urology.

    PubMed

    Johnson, D E; Cromeens, D M; Price, R E

    1992-01-01

    The tissue effects of a holmium:YAG (Ho:YAG) laser operating at a wavelength of 2.1 mu with a maximum power of 15 watts (W) and 10 different energy-pulse settings was systematically evaluated on kidney, bladder, prostate, ureteral, and vasal tissue in the dog. In addition, various urologic surgical procedures (partial nephrectomy, transurethral laser incision of the prostate, and laser-assisted vasovasostomy) were performed in the dog, and a laparoscopic pelvic lymph node dissection was carried out in a pig. Although the Ho:YAG laser has a strong affinity for water, precise tissue ablation was achieved in both the contact and non-contact mode when used endoscopically in a fluid medium to ablate prostatic and vesical tissue. Using the usual parameters for tissue destruction (blanching without charring), the depth of thermal injury in the bladder and ureter was kept superficial. In performing partial nephrectomies, a 2-fold reduction in the zone of coagulative necrosis was demonstrated compared to the use of the continuous wave Neodymium:YAG laser (Nd:YAG). When used through the laparoscope, the Ho:YAG laser provided precise cutting and, combined with electrocautery, allowed the dissection to proceed quickly and smoothly. Hemostatic control was adequate in all surgical procedures. Although the results of these investigations are preliminary, our initial experience with the Ho:YAG laser has been favorable and warrants further investigations.

  9. Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions: Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention).

    PubMed

    Mahmud, Ehtisham; Naghi, Jesse; Ang, Lawrence; Harrison, Jonathan; Behnamfar, Omid; Pourdjabbar, Ali; Reeves, Ryan; Patel, Mitul

    2017-07-10

    The aims of this study were to evaluate the feasibility and technical success of robotically assisted percutaneous coronary intervention (R-PCI) for the treatment of coronary artery disease (CAD) in clinical practice, especially in complex lesions, and to determine the safety and clinical success of R-PCI compared with manual percutaneous coronary intervention (M-PCI). R-PCI is safe and feasible for simple coronary lesions. The utility of R-PCI for complex coronary lesions is unknown. All consecutive PCI procedures performed robotically (study group) or manually (control group) over 18 months were included. R-PCI technical success, defined as the completion of the procedure robotically or with partial manual assistance and without a major adverse cardiovascular event, was determined. Procedures ineligible for R-PCI (i.e., atherectomy, planned 2-stent strategy for bifurcation lesion, chronic total occlusion requiring hybrid approach) were excluded for analysis from the M-PCI group. Clinical success, defined as completion of the PCI procedure without a major adverse cardiovascular event, procedure time, stent use, and fluoroscopy time were compared between groups. A total of 315 patients (mean age 67.7 ± 11.8 years; 78% men) underwent 334 PCI procedures (108 R-PCIs, 157 lesions, 78.3% type B2/C; 226 M-PCIs, 336 lesions, 68.8% type B2/C). Technical success with R-PCI was 91.7% (rate of manual assistance 11.1%, rate of manual conversion 7.4%, rate of major adverse cardiovascular events 0.93%). Clinical success (99.1% with R-PCI vs. 99.1% with M-PCI; p = 1.00), stent use (stents per procedure 1.59 ± 0.79 with R-PCI vs. 1.54 ± 0.75 with M-PCI; p = 0.73), and fluoroscopy time (18.2 ± 10.4 min with R-PCI vs. 19.2 ± 11.4 min with M-PCI; p = 0.39) were similar between the groups, although procedure time was longer in the R-PCI group (44:30 ± 26:04 min:s vs. 36:34 ± 23:03 min:s; p = 0.002). Propensity-matched analysis confirmed that procedure time was longer in the robotic group (42:59 ± 26:14 min:s with R-PCI vs. 34:01 ± 17:14 min:s with M-PCI; p = 0.007), although clinical success remained similar (98.8% with R-PCI vs. 100% with M-PCI; p = 1.00). This study demonstrates the feasibility, safety, and high technical success of R-PCI for the treatment of complex coronary disease. Furthermore, comparable clinical outcomes, without an adverse effect on stent use or fluoroscopy time, were observed with R-PCI and M-PCI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. A case of robot-assisted laparoscopic radical prostatectomy in primary small cell prostate cancer.

    PubMed

    Kim, Ki Hong; Park, Sang Un; Jang, Jee Young; Park, Won Kyu; Oh, Chul Kyu; Rha, Koon Ho

    2010-12-01

    Primary small cell carcinoma of the prostate is a rare and very aggressive disease with a poor prognosis, even in its localized form. We managed a case of primary small cell carcinoma of the prostate. The patient was treated with robot-assisted laparoscopic radical prostatectomy and adjuvant chemotherapy. Herein we report this first case of robot-assisted laparoscopic radical prostatectomy performed in a patient with primary small cell carcinoma of the prostate.

  11. Functional assessment and performance evaluation for assistive robotic manipulators: Literature review

    PubMed Central

    Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A.

    2013-01-01

    Context The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. Methods We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System – PITTCat. Results Twenty relevant studies were identified. Conclusion Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators. PMID:23820143

  12. Interactive Games with an Assistive Robotic System for Hearing-Impaired Children.

    PubMed

    Uluer, Pinar; Akalin, Neziha; Gurpinar, Cemal; Kose, Hatice

    2017-01-01

    This paper presents an assistive robotic system, which can recognize and express sign language words from a predefined set, within interactive games to communicate with and teach hearing-impaired children sign language. The robotic system uses audio, visual and tactile feedback for interaction with the children and the teacher/researcher.

  13. Hysterectomy

    MedlinePlus

    ... which is called a laparoscopic vaginal hysterectomy). A robot-assisted laparoscopic hysterectomy is performed with the help ... In general, it has not been shown that robot-assisted laparoscopy results in a better outcome than ...

  14. Direct interaction with an assistive robot for individuals with chronic stroke.

    PubMed

    Kmetz, Brandon; Markham, Heather; Brewer, Bambi R

    2011-01-01

    Many robotic systems have been developed to provide assistance to individuals with disabilities. Most of these systems require the individual to interact with the robot via a joystick or keypad, though some utilize techniques such as speech recognition or selection of objects with a laser pointer. In this paper, we describe a prototype system using a novel method of interaction with an assistive robot. A touch-sensitive skin enables the user to directly guide a robotic arm to a desired position. When the skin is released, the robot remains fixed in position. The target population for this system is individuals with hemiparesis due to chronic stroke. The system can be used as a substitute for the paretic arm and hand in bimanual tasks such as holding a jar while removing the lid. This paper describes the hardware and software of the prototype system, which includes a robotic arm, the touch-sensitive skin, a hook-style prehensor, and weight compensation and speech recognition software.

  15. [Robotic assistance in gynaecological surgery: State-of-the-art].

    PubMed

    Monsarrat, N; Collinet, P; Narducci, F; Leblanc, E; Vinatier, D

    2009-05-01

    From the Automated Endoscopic System for Optimal Positioning (AESOP), a robotic arm which operates the laparoscope, to the robots Zeus and da Vinci, robotic assistance in gynaecological endoscopic surgery has continuously evolved for the last fifteen years or so. It has brought about new technical advancements: the last generation robots offer a steady three-dimensional image, improved instrument dexterity and precision, higher ergonomics and comfort for the surgeon. The da Vinci robotic system has been used without evincing any specific morbidity in various cases, notably for tubal reanastomosis, myomectomy, hysterectomy, pelvic and para-aortic lymphadenectomy or sacrocolpopexy amongst others. Robotic assistance in gynaecology is thus feasible. Like conventional laparoscopic surgery, it allows decreased blood loss and morbidity as well as shorter hospital stay, as compared to laparotomy. It might indeed allow many surgical teams to perform minimally invasive surgical procedures which they were not used to performing by laparoscopy. Randomized prospective studies are needed to define its indications more precisely. Besides, its medico-financial impact should be evaluated too.

  16. Robotic microsurgery in male infertility and urology-taking robotics to the next level.

    PubMed

    Gudeloglu, Ahmet; Brahmbhatt, Jamin V; Parekattil, Sijo J

    2014-03-01

    The initial reports of robotic assisted microsurgery began to appear in the early 1990s. Animal and early human studies were the initial publications. Larger series papers have recently been published from a few institutions. The field of robotic assisted microsurgery is still in evolution and so are adjunctive tools and instruments. It is clearly a different and unique skill set-is it microsurgery or is it robotic surgery, or both. It is clear from history that the art of surgery evolves over time to encompass new technology as long as the outcomes are better for the patient. Our current robotic platforms may not be ideal for microsurgery, however, the use of adjunctive tools and instrument refinement will further its future potential. This review article presents the current state of the art in various robotic assisted microsurgical procedures in male infertility and urology. Some novel applications of taking microsurgery to areas not classically accessible (intra-abdominal vasovasostomy) and adjunctive tools will also be presented.

  17. The "halo effect" in Korea: change in practice patterns since the introduction of robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Sung, Ee-Rah; Jeong, Wooju; Park, Sung Yul; Ham, Won Sik; Choi, Young Deuk; Hong, Sung Joon; Rha, Koon Ho

    2009-03-01

    Acquisition of the da Vinci surgical system (Intuitive Surgical, Mountain View, USA) has enabled robot-assisted surgery to become an acceptable alternative to open radical prostatectomy (ORP). Implementation of robotics at a single institution in Korea induced a gradual increase in the number of performances of robot-assisted laparoscopic radical prostatectomy (RALP) to surgically treat localized prostate cancer. We analyzed the impact of robotic instrumentation on practice patterns among urologists and explain the change in value in ORP and RALP-the standard treatment and the new approach or innovation of robotic technology. The overall number of prostatectomies has increased over time because the number of RALPs has grown drastically whereas the number of OPRs did not decrease during the period of evaluation. Our experience emphasizes the potential of RALP to become the gold standard in the treatment of localized prostate cancer in various parts of the world.

  18. Robot-assisted antegrade in-situ fenestrated stent grafting.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-05-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  19. ACOG Technology Assessment in Obstetrics and Gynecology No. 6: Robot-assisted surgery.

    PubMed

    2009-11-01

    The field of robotic surgery is developing rapidly, but experience with this technology is currently limited. In response to increasing interest in robotics technology, the Committee on Gynecologic Practice's Technology Assessment was developed to describe the robotic surgical system,potential advantages and disadvantages, gynecologic applications, and the current state of the evidence. Randomized trials comparing robot-assisted surgery with traditional laparoscopic, vaginal, or abdominal surgery are needed to evaluate long-term clinical outcomes and cost-effectiveness, as well as to identify the best applications of this technology.

  20. Atypical autonomic dysreflexia during robotic-assisted body weight supported treadmill training in an individual with motor incomplete spinal cord injury.

    PubMed

    Geigle, Paula R; Frye, Sara Kate; Perreault, John; Scott, William H; Gorman, Peter H

    2013-03-01

    A 41-year-old man with a history of C6 American Spinal Injury Association (ASIA) Impairment Scale (AIS) C spinal cord injury (SCI), enrolled in an Institutional Review Board (IRB)-approved, robotic-assisted body weight-supported treadmill training (BWSTT), and aquatic exercise research protocol developed asymptomatic autonomic dysreflexia (AD) during training. Little information is available regarding the relationship of robotic-assisted BWSTT and AD. After successfully completing 36 sessions of aquatic exercise, he reported exertional fatigue during his 10th Lokomat intervention and exhibited asymptomatic or silent AD during this and the three subsequent BWSTT sessions. Standard facilitators of AD were assessed and no obvious irritant identified other than the actual physical exertion and positioning required during robotic-assisted BWSTT. Increased awareness of potential silent AD presenting during robotic assisted BWSTT training for individuals with motor incomplete SCI is required as in this case AD clinical signs were not concurrent with occurrence. Frequent vital sign assessment before, during, and at conclusion of each BWSTT session is strongly recommended.

  1. New suturing technique for robotic-assisted vaginal cuff closure during single-site hysterectomy.

    PubMed

    Shin, So-Jin; Chung, Hyewon; Kwon, Sang-Hoon; Cha, Soon-Do; Cho, Chi-Heum

    2017-06-01

    To describe a simple and efficient technique for suturing the vaginal cuff in robotic-assisted single-site hysterectomy using barbed suture and a straight needle. Consecutive patients undergoing robotic-assisted single-site hysterectomy from February 2014 to August 2015 at Dong San Hospital, Keimyung University were included. Surgeons used two barbed sutures in a running fashion to close the vaginal cuff. A barbed suture was exclusively used with a straightened needle in upward direction from posterior vaginal cuff to anterior vaginal cuff which played a pivotal role for closure. A total of 100 patients underwent robotic-assisted single-site hysterectomy. The total operation time was 132.5 min and vaginal cuff closure time was 12.0 min. There were no postoperative complications; vaginal cuff dehiscence, vaginal cuff infection, and vaginal bleeding that require surgical intervention or admission. The use of barbed suture with straightened needle to close the vaginal cuff in robotic-assisted single-site hysterectomy is easy to perform and demonstrates safety and efficacy. This technique offers secure, fast, and effective incision closure.

  2. Retention of robot-assisted surgical skills in urological surgeons acquired using Mimic dV-Trainer.

    PubMed

    Teishima, Jun; Hattori, Minoru; Inoue, Shogo; Ikeda, Kenichiro; Hieda, Keisuke; Ohara, Shinya; Egi, Hiroyuki; Ohdan, Hideki; Matsubara, Akio

    2014-07-01

    We assess the retention of robot-assisted surgical skills among urologic surgeons. The robot-assisted surgery skills of 20 urologic surgeons were assessed using a Mimic dV-Trainer program (Mimic Technologies, Inc., Seattle, WA) consisting of 6 tasks. These 20 surgeons had no previous experience either using the Mimic dV-Trainer or acting as the main surgeon in robot-assisted surgery. The surgeons completed the program 4 times in a row; after 1 year, they completed it again for a fifth time. Performance scores were recorded using the Mimic dV-Trainer's built-in algorithm. For all 6 tasks, there were significant improvements to the scores in the fourth trials compared with those in the first trials. The scores in the fifth trials did not significantly decline compared with those in the fourth trials. There was no significant difference between the fifth trial scores of surgeons with laparoscopic surgery skills/experience and those without. Our results indicate that fundamental robot-assisted surgical skills can be retained in the long-term after they are acquired.

  3. A New Approach for Human Forearm Motion Assist by Actuated Artificial Joint-An Inner Skeleton Robot

    NASA Astrophysics Data System (ADS)

    Kundu, Subrata Kumar; Kiguchi, Kazuo; Teramoto, Kenbu

    In order to help the physical activities of the elderly or physically disabled persons, we propose a new concept of a power-assist inner skeleton robot (i.e., actuated artificial joint) that is supposed to assist the human daily life motion from inside of the human body. This paper presents an implantable 2 degree of freedom (DOF) inner skeleton robot that is designed to assist human elbow flexion-extension motion and forearm supination-pronation motion for daily life activities. We have developed a prototype of the inner skeleton robot that is supposed to assist the motion from inside of the body and act as an actuated artificial joint. The proposed system is controlled based on the activation patterns of the electromyogram (EMG) signals of the user's muscles by applying fuzzy-neuro control method. A joint actuator with angular position sensor is designed for the inner skeleton robot and a T-Mechanism is proposed to keep the bone arrangement similar to the normal human articulation after the elbow arthroplasty. The effectiveness of the proposed system has been evaluated by experiment.

  4. Robotic thyroidectomy learning curve for beginning surgeons with little or no experience of endoscopic surgery.

    PubMed

    Park, Jae Hyun; Lee, Jandee; Hakim, Nor Azham; Kim, Ha Yan; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Bae, Keum-Seok; Kang, Seong Joon; Chung, Woong Youn

    2015-12-01

    This study assessed the results of robotic thyroidectomy by fellowship-trained surgeons in their initial independent practice, and whether standard fellowship training for robotic surgery shortens the learning curve. This prospective cohort study evaluated outcomes in 125 patients who underwent robotic thyroidectomy using gasless transaxillary single-incision technique by 2 recently graduated fellowship-trained surgeons. Learning curves were analyzed by operation time, with proficiency defined as the point at which the slope of the time curve became less steep. Of the 125 patients, 113 underwent robotic less-than-total thyroidectomy, 9 underwent robotic total thyroidectomy and 3 underwent robotic total thyroidectomy with modified radical neck dissection. Mean total times for these 3 operations were 100.8 ± 20.6 minutes, 134.2 ± 38.7 minutes, and 284.7 ± 60.4 minutes, respectively. For both surgeons, the operation times gradually decreased, reaching a plateau after 20 robotic less-than-total thyroidectomies. The surgical learning curve for robotic thyroidectomy performed by recently graduated fellowship-trained surgeons with little or no experience in endoscopic surgery showed excellent results compared with those in a large series of more experienced surgeons. © 2014 Wiley Periodicals, Inc.

  5. Conventional versus robot-assisted laparoscopic Nissen fundoplication: a comparison of postoperative acid reflux parameters.

    PubMed

    Frazzoni, Marzio; Conigliaro, Rita; Colli, Giovanni; Melotti, Gianluigi

    2012-06-01

    Laparoscopic Nissen fundoplication (LNF) is a technically demanding surgical procedure designed to cure gastroesophageal reflux disease (GERD). It represents an alternative to life-long medical therapy and the only recommended treatment modality to overcome refractoriness to proton pump inhibitor (PPI) therapy. The recent development of robotic systems prompted evaluation of their use in antireflux surgery. Between 1997 and 2000, in a PPI-responsive series we found postoperative normalization of esophageal acid exposure time (EAET) in most but not all cases. Between 2007 and 2009, in a PPI-refractory series we found postoperative normalization of EAET in all cases. We decided to analyze retrospectively our prospectively collected data to evaluate whether differences other than the conventional or robot-assisted technique could justify postoperative differences in acid reflux parameters. Baseline demographic, endoscopic, and manometric parameters were compared between the two series of patients, as well as postoperative manometric and acid reflux parameters. There were no significant differences in the baseline demographic, endoscopic, and manometric characteristics between the two groups of patients. The median lower esophageal sphincter tone increased significantly, and the median EAET decreased significantly after conventional as well as after robot-assisted LNF. The median postoperative EAET was significantly lower in the robot-assisted (0.2%) than in the conventional LNF group (1%; P = 0.001). Abnormal EAET values were found in 6 of 44 (14%) and in 0 of 44 cases after conventional and robot-assisted LNF, respectively (P = 0.026). Robot-assisted LNF provided a significant gain in postoperative acid reflux parameters compared with the conventional technique. In a challenging clinical setting, such as PPI-refractoriness, in which the efficacy of endoscopic or pharmacological treatment modalities is only moderate, even a small therapeutic gain can be clinically relevant. In centers where robot-assisted LNF is available, it should be preferred to conventional LNF in PPI-refractory GERD.

  6. Gait performance and foot pressure distribution during wearable robot-assisted gait in elderly adults.

    PubMed

    Lee, Su-Hyun; Lee, Hwang-Jae; Chang, Won Hyuk; Choi, Byung-Ok; Lee, Jusuk; Kim, Jeonghun; Ryu, Gyu-Ha; Kim, Yun-Hee

    2017-11-28

    A robotic exoskeleton device is an intelligent system designed to improve gait performance and quality of life for the wearer. Robotic technology has developed rapidly in recent years, and several robot-assisted gait devices were developed to enhance gait function and activities of daily living in elderly adults and patients with gait disorders. In this study, we investigated the effects of the Gait-enhancing Mechatronic System (GEMS), a new wearable robotic hip-assist device developed by Samsung Electronics Co, Ltd., Korea, on gait performance and foot pressure distribution in elderly adults. Thirty elderly adults who had no neurological or musculoskeletal abnormalities affecting gait participated in this study. A three-dimensional (3D) motion capture system, surface electromyography and the F-Scan system were used to collect data on spatiotemporal gait parameters, muscle activity and foot pressure distribution under three conditions: free gait without robot assistance (FG), robot-assisted gait with zero torque (RAG-Z) and robot-assisted gait (RAG). We found increased gait speed, cadence, stride length and single support time in the RAG condition. Reduced rectus femoris and medial gastrocnemius muscle activity throughout the terminal stance phase and reduced effort of the medial gastrocnemius muscle throughout the pre-swing phase were also observed in the RAG condition. In addition, walking with the assistance of GEMS resulted in a significant increase in foot pressure distribution, specifically in maximum force and peak pressure of the total foot, medial masks, anterior masks and posterior masks. The results of the present study reveal that GEMS may present an alternative way of restoring age-related changes in gait such as gait instability with muscle weakness, reduced step force and lower foot pressure in elderly adults. In addition, GEMS improved gait performance by improving push-off power and walking speed and reducing muscle activity in the lower extremities. NCT02843828 .

  7. Control of robotic assistance using poststroke residual voluntary effort.

    PubMed

    Makowski, Nathaniel S; Knutson, Jayme S; Chae, John; Crago, Patrick E

    2015-03-01

    Poststroke hemiparesis limits the ability to reach, in part due to involuntary muscle co-activation (synergies). Robotic approaches are being developed for both therapeutic benefit and continuous assistance during activities of daily living. Robotic assistance may enable participants to exert less effort, thereby reducing expression of the abnormal co-activation patterns, which could allow participants to reach further. This study evaluated how well participants could perform a reaching task with robotic assistance that was either provided independent of effort in the vertical direction or in the sagittal plane in proportion to voluntary effort estimated from electromyograms (EMG) on the affected side. Participants who could not reach targets without assistance were enabled to reach further with assistance. Constant anti-gravity force assistance that was independent of voluntary effort did not reduce the quality of reach and enabled participants to exert less effort while maintaining different target locations. Force assistance that was proportional to voluntary effort on the affected side enabled participants to exert less effort and could be controlled to successfully reach targets, but participants had increased difficulty maintaining a stable position. These results suggest that residual effort on the affected side can produce an effective command signal for poststroke assistive devices.

  8. Comparative outcomes and assessment of trifecta in 500 robotic and laparoscopic partial nephrectomy cases: a single surgeon experience.

    PubMed

    Khalifeh, Ali; Autorino, Riccardo; Hillyer, Shahab P; Laydner, Humberto; Eyraud, Remi; Panumatrassamee, Kamol; Long, Jean-Alexandre; Kaouk, Jihad H

    2013-04-01

    We report a comparative analysis of a large series of laparoscopic and robotic partial nephrectomies performed by a high volume single surgeon at a tertiary care institution. We retrospectively reviewed the medical charts of 500 patients treated with minimally invasive partial nephrectomy by a single surgeon between March 2002 and February 2012. Demographic and perioperative data were collected and statistically analyzed. R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to the collecting system or sinus in mm, anterior/posterior and location relative to polar lines) nephrometry score was used to score tumors. Those scored as moderate and high complexity were designated as complex. Trifecta was defined as a combination of warm ischemia time less than 25 minutes, negative surgical margins and no perioperative complications. Two groups were identified, including 261 patients with robotic and 231 with laparoscopic partial nephrectomy. Demographics were similar in the groups. The robotic group was significantly more morbid (Charlson comorbidity index 3.75 vs 1.26), included more complex tumors (R.E.N.A.L. score 5.98 vs 7.2), and had lower operative (169.9 vs 191.7 minutes) and warm ischemia (17.9 vs 25.2 minutes) time, intraoperative (2.6% vs 5.6%, each p <0.001) and postoperative (24.53% vs 32.03%, p = 0.004) complications, and positive margin rate (2.9% vs 5.6%, p <0.001). Thus, a higher overall trifecta rate was observed for robotic partial nephrectomy (58.7% vs 31.6%, p <0.001). The laparoscopic group had longer followup (3.43 vs 1.51 years, p <0.001) and no significant difference in postoperative changes in renal function. Main study limitations were the retrospective nature, arbitrary definition of trifecta and shorter followup in the RPN group. Our large comparative analysis shows that robotic partial nephrectomy offers a wider range of indications, better operative outcomes and lower perioperative morbidity than laparoscopic partial nephrectomy. Overall, the quest for trifecta seems to be better accomplished by robotic partial nephrectomy, which is likely to become the new standard for minimally invasive partial nephrectomy. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Perioperative pain after robot-assisted versus laparoscopic rectal resection.

    PubMed

    Tolstrup, Rikke; Funder, Jonas Amstrup; Lundbech, Liselotte; Thomassen, Niels; Iversen, Lene Hjerrild

    2018-03-01

    In order to improve the surgical treatment of rectal cancer, robot-assisted laparoscopy has been introduced. The robot has gained widespread use; however, the scientific basis for treatment of rectal cancer is still unclear. The aim of this study was to investigate whether robot-assisted laparoscopic rectal resection cause less perioperative pain than standard laparoscopic resection measured by the numerical rating scale (NRS score) as well as morphine consumption. Fifty-one patients were randomized to either laparoscopic or robot-assisted rectal resection at the Department of Surgery at Aarhus University Hospital in Denmark. The intra-operative analgetic consumption was recorded prospectively and registered in patient records. Likewise all postoperative medicine administration including analgesia was recorded prospectively at the hospital medical charts. All morphine analogues were converted into equivalent oral morphine by a converter. Postoperative pain where measured by numeric rating scale (NRS) every hour at the postoperative care unit and three times a day at the ward. Opioid consumption during operation was significantly lower during robotic-assisted surgery than during laparoscopic surgery (p=0.0001). However, there were no differences in opioid consumption or NRS in the period of recovery. We found no differences in length of surgery between the two groups; however, ten patients from the laparoscopic group underwent conversion to open surgery compared to one from the robotic group (p=0.005). No significant difference between groups with respect to complications where found. In the present study, we found that patients who underwent rectal cancer resection by robotic technique needed less analgetics during surgery than patients operated laparoscopically. We did, however, not find any difference in postoperative pain score or morphine consumption postoperatively between the robotic and laparoscopic group.

  10. Robot-assisted upper extremity rehabilitation for cervical spinal cord injuries: a systematic scoping review.

    PubMed

    Singh, Hardeep; Unger, Janelle; Zariffa, José; Pakosh, Maureen; Jaglal, Susan; Craven, B Catharine; Musselman, Kristin E

    2018-01-15

    Abstact Purpose: To provide an overview of the feasibility and outcomes of robotic-assisted upper extremity training for individuals with cervical spinal cord injury (SCI), and to identify gaps in current research and articulate future research directions. A systematic search was conducted using Medline, Embase, PsycINFO, CCTR, CDSR, CINAHL and PubMed on June 7, 2017. Search terms included 3 themes: (1) robotics; (2) SCI; (3) upper extremity. Studies using robots for upper extremity rehabilitation among individuals with cervical SCI were included. Identified articles were independently reviewed by two researchers and compared to pre-specified criteria. Disagreements regarding article inclusion were resolved through discussion. The modified Downs and Black checklist was used to assess article quality. Participant characteristics, study and intervention details, training outcomes, robot features, study limitations and recommendations for future studies were abstracted from included articles. Twelve articles (one randomized clinical trial, six case series, five case studies) met the inclusion criteria. Five robots were exoskeletons and three were end-effectors. Sample sizes ranged from 1 to 17 subjects. Articles had variable quality, with quality scores ranging from 8 to 20. Studies had a low internal validity primarily from lack of blinding or a control group. Individuals with mild-moderate impairments showed the greatest improvements on body structure/function and performance-level measures. This review is limited by the small number of articles, low-sample sizes and the diversity of devices and their associated training protocols, and outcome measures. Preliminary evidence suggests robot-assisted interventions are safe, feasible and can reduce active assistance provided by therapists. Implications for rehabilitation Robot-assisted upper extremity training for individuals with cervical spinal cord injury is safe, feasible and can reduce hands-on assistance provided by therapists. Future research in robotics rehabilitation with individuals with spinal cord injury is needed to determine the optimal device and training protocol as well as effectiveness.

  11. Thermal Image Sensing Model for Robotic Planning and Search.

    PubMed

    Castro Jiménez, Lídice E; Martínez-García, Edgar A

    2016-08-08

    This work presents a search planning system for a rolling robot to find a source of infra-red (IR) radiation at an unknown location. Heat emissions are observed by a low-cost home-made IR passive visual sensor. The sensor capability for detection of radiation spectra was experimentally characterized. The sensor data were modeled by an exponential model to estimate the distance as a function of the IR image's intensity, and, a polynomial model to estimate temperature as a function of IR intensities. Both theoretical models are combined to deduce a subtle nonlinear exact solution via distance-temperature. A planning system obtains feed back from the IR camera (position, intensity, and temperature) to lead the robot to find the heat source. The planner is a system of nonlinear equations recursively solved by a Newton-based approach to estimate the IR-source in global coordinates. The planning system assists an autonomous navigation control in order to reach the goal and avoid collisions. Trigonometric partial differential equations were established to control the robot's course towards the heat emission. A sine function produces attractive accelerations toward the IR source. A cosine function produces repulsive accelerations against the obstacles observed by an RGB-D sensor. Simulations and real experiments of complex indoor are presented to illustrate the convenience and efficacy of the proposed approach.

  12. Robotic inferior vena cava surgery.

    PubMed

    Davila, Victor J; Velazco, Cristine S; Stone, William M; Fowl, Richard J; Abdul-Muhsin, Haidar M; Castle, Erik P; Money, Samuel R

    2017-03-01

    Inferior vena cava (IVC) surgery is uncommon and has traditionally been performed through open surgical approaches. Renal cell carcinoma with IVC extension generally requires vena cavotomy and reconstruction. Open removal of malpositioned IVC filters (IVCF) is occasionally required after endovascular retrieval attempts have failed. As our experience with robotic surgery has advanced, we have applied this technology to surgery of the IVC. We reviewed our institution's experience with robotic surgical procedures involving the IVC to determine its safety and efficacy. All patients undergoing robotic surgery that included cavotomy and repair from 2011 to 2014 were retrospectively reviewed. Data were obtained detailing preoperative demographics, operative details, and postoperative morbidity and mortality. Ten patients (6 men) underwent robotic vena caval procedures at our institution. Seven patients underwent robotic nephrectomy with removal of IVC tumor thrombus and retroperitoneal lymph node dissection. Three patients underwent robotic explantation of an IVCF after multiple endovascular attempts at removal had failed. The patients with renal cell carcinoma were a mean age of was 65.4 years (range, 55-74 years). Six patients had right-sided malignancy. All patients had T3b lesions at time of diagnosis. Mean tumor length extension into the IVC was 5 cm (range, 1-8 cm). All patients underwent robotic radical nephrectomy, with caval tumor thrombus removal and retroperitoneal lymph node dissection. The average operative time for patients undergoing surgery for renal cell carcinoma was 273 minutes (range, 137-382 minutes). Average intraoperative blood loss was 428 mL (range, 150-1200 mL). The patients with IVCF removal were a mean age of 33 years (range, 24-41 years). Average time from IVCF placement until robotic removal was 35.5 months (range, 4.3-57.3 months). Before robotic IVCF removal, a minimum of two endovascular retrievals were attempted. Average operative time for patients undergoing IVCF removal was 163 minutes (range, 131-202 minutes). Intraoperative blood loss averaged 250 mL (range, 150-350 mL). All procedures were completed robotically. The mean length of stay for all patients was 3.5 days (range, 1-8 days). All patients resumed ambulation on postoperative day 1. Nine patients resumed a regular diet on postoperative day 2. One patient with a renal tumor sustained a colon injury during initial adhesiolysis, before robotic radical nephrectomy, which was recognized at the initial operation and repaired robotically. Robotic radical nephrectomy and caval tumor removal were then completed. No blood transfusions were required intraoperatively, but three patients required blood transfusions postoperatively. Although robotic IVC surgery is uncommon, our initial limited experience demonstrates it is safe and efficacious. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. An immune-inspired swarm aggregation algorithm for self-healing swarm robotic systems.

    PubMed

    Timmis, J; Ismail, A R; Bjerknes, J D; Winfield, A F T

    2016-08-01

    Swarm robotics is concerned with the decentralised coordination of multiple robots having only limited communication and interaction abilities. Although fault tolerance and robustness to individual robot failures have often been used to justify the use of swarm robotic systems, recent studies have shown that swarm robotic systems are susceptible to certain types of failure. In this paper we propose an approach to self-healing swarm robotic systems and take inspiration from the process of granuloma formation, a process of containment and repair found in the immune system. We use a case study of a swarm performing team work where previous works have demonstrated that partially failed robots have the most detrimental effect on overall swarm behaviour. We have developed an immune inspired approach that permits the recovery from certain failure modes during operation of the swarm, overcoming issues that effect swarm behaviour associated with partially failed robots. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Virtual reality-assisted robotic surgery simulation.

    PubMed

    Albani, Justin M; Lee, David I

    2007-03-01

    For more than a decade, advancing computer technologies have allowed incorporation of virtual reality (VR) into surgical training. This has become especially important in training for laparoscopic procedures, which often are complex and leave little room for error. With the advent of robotic surgery and the development and prevalence of a commercial surgical system (da Vinci robot; Intuitive Surgical, Sunnyvale, CA), a valid VR-assisted robotic surgery simulator could minimize the steep learning curve associated with many of these complex procedures and thus enable better outcomes. To date, such simulation does not exist; however, several agencies and corporations are involved in making this dream a reality. We review the history and progress of VR simulation in surgical training, its promising applications in robotic-assisted surgery, and the remaining challenges to implementation.

  15. AAL robotics: state of the field and challenges.

    PubMed

    Payr, Sabine; Werner, Franz; Werner, Katharina

    2015-01-01

    The field of "AAL Robotics", combining AAL and robotics as disciplines, has not yet been precisely defined and does not present accepted structures and concepts that would allow to communicate unequivocally its methods, projects, and approaches. The paper presents a method of defining and categorizing AAL robots and presents the resulting classes of robots with regard to the activities they assist. The classification is useful in that it is able to cover the breadth of the field, but a more fine-grained description of functionalities will be needed in further research to establish the potential of robots to assist independent living of older adults.

  16. Robotic Lung Resection for Non-Small Cell Lung Cancer.

    PubMed

    Wei, Benjamin; Eldaif, Shady M; Cerfolio, Robert J

    2016-07-01

    Robotic-assisted pulmonary lobectomy can be considered for patients able to tolerate conventional lobectomy. Contraindications to resection via thoracotomy apply to patients undergoing robotic lobectomy. Team training, familiarity with equipment, troubleshooting, and preparation are critical for successful robotic lobectomy. Robotic lobectomy is associated with decreased rates of blood loss, blood transfusion, air leak, chest tube duration, length of stay, and mortality compared with thoracotomy. Robotic lobectomy offers many of the same benefits in perioperative morbidity and mortality, and additional advantages in optics, dexterity, and surgeon ergonomics as video-assisted thoracic lobectomy. Long-term oncologic efficacy and cost implications remain areas of study. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Pediatric robotic-assisted laparoscopic augmentation ileocystoplasty and Mitrofanoff appendicovesicostomy: complete intracorporeal--initial case report.

    PubMed

    Gundeti, Mohan S; Eng, Michael K; Reynolds, W Stuart; Zagaja, Gregory P

    2008-11-01

    To the best of our knowledge, we report the first case of complete intracorporeal robotic-assisted laparoscopic augmentation ileocystoplasty and Mitrofanoff appendicovesicostomy in a pediatric patient, outlining the surgical technique and short-term results. The operative steps of the open procedure were replicated laparoscopically using robotic-assistance. In brief, 5 transperitoneal laparoscopic ports were placed before docking the da Vinci S robotic system. A 20-cm ileal segment was isolated, and the gastrointestinal anastomosis was performed in an end-to-end fashion using intracorporeal suturing. The appendix was anastomosed to the right posterior wall of the bladder over an 8F feeding tube in an extravesical fashion. The bladder was incised in a coronal plane, and the simple ileal on-lay patch was anastomosed to the posterior and anterior walls of the bladder. A suprapubic catheter and pelvic drain were placed, and the Mitrofanoff stoma was then fashioned. Cystography was performed at 4 weeks postoperatively. This preliminary first successful report suggests that robotic-assisted ileocystoplasty and appendicovesicostomy is feasible. A reasonable outcome with early recovery, resumption of normal activities, and excellent cosmesis can be achieved in selected patients. However, whether a robotic-assisted approach provides any significant advantages over conventional open procedures is yet to be determined with a large case series.

  18. [Robotic-assisted laparoscopy for deep infiltrating endometriosis: the Register of the Society of European Robotic Gynaecological Surgery].

    PubMed

    Hanssens, S; Nisolle, M; Leguevaque, P; Neme, R M; Cela, V; Barton-Smith, P; Hébert, T; Collinet, P

    2014-11-01

    To assess the interest of robotic-assisted laparoscopy in the context of deep infiltrating endometriosis and to investigate perioperative results. From November 2008 to April 2012, 164 women with stage IV endometriosis who underwent robotic-assisted laparoscopy (DA VINCI Intuitive Surgical System(®)) were included by eight international participating clinical centers. Patients were divided in 4 groups according to the localization of the nodule(s): rectum (n=88), bladder (n=23), ureter and uterosacral ligaments (n=115) et hysterectomy (n=28). We evaluated the procedures performed, the duration of intervention, the complications, the recurrence and the impact on fertility. In the rectum group, there was a laparotomy conversion, 2 sutured rectal injuries and a red cells blood transfusion. In the bladder group, there was a vesicovaginal hematoma and a prolongated intermittent self-catheterization. In the ureter and uterosacral ligaments group, there was 2 ureteral fistulas and there was no complication in the hysterectomy group. This study is the largest series published in the literature on robotic-assisted laparoscopy for deep infiltrating endometriosis. The interest of robotic-assisted laparoscopy in deep infiltrating endometriosis seems to be promising while no increase in surgical time, blood loss, and intra- and postoperative complications were observed. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. The Arrival of Robotics in Spine Surgery: A Review of the Literature.

    PubMed

    Ghasem, Alexander; Sharma, Akhil; Greif, Dylan N; Alam, Milad; Maaieh, Motasem Al

    2018-04-18

    Systematic Review. The authors aim to review comparative outcome measures between robotic and free-hand spine surgical procedures including: accuracy of spinal instrumentation, radiation exposure, operative time, hospital stay, and complication rates. Misplacement of pedicle screws in conventional open as well as minimally invasive surgical procedures has prompted the need for innovation and allowed the emergence of robotics in spine surgery. Prior to incorporation of robotic surgery in routine practice, demonstration of improved instrumentation accuracy, operative efficiency, and patient safety is required. A systematic search of the PubMed, OVID-MEDLINE, and Cochrane databases was performed for papers relevant to robotic assistance of pedicle screw placement. Inclusion criteria were constituted by English written randomized control trials, prospective and retrospective cohort studies involving robotic instrumentation in the spine. Following abstract, title, and full-text review, 32 articles were selected for study inclusion. Intrapedicular accuracy in screw placement and subsequent complications were at least comparable if not superior in the robotic surgery cohort. There is evidence supporting that total operative time is prolonged in robot assisted surgery compared to conventional free-hand. Radiation exposure appeared to be variable between studies; radiation time did decrease in the robot arm as the total number of robotic cases ascended, suggesting a learning curve effect. Multi-level procedures appeared to tend toward earlier discharge in patients undergoing robotic spine surgery. The implementation of robotic technology for pedicle screw placement yields an acceptable level of accuracy on a highly consistent basis. Surgeons should remain vigilant about confirmation of robotic assisted screw trajectory, as drilling pathways have been shown to be altered by soft tissue pressures, forceful surgical application, and bony surface skiving. However, the effective consequence of robot-assistance on radiation exposure, length of stay, and operative time remains unclear and requires meticulous examination in future studies. 4.

  20. Functional outcomes following robotic prostatectomy using athermal, traction free risk-stratified grades of nerve sparing.

    PubMed

    Tewari, Ashutosh K; Ali, Adnan; Metgud, Sheela; Theckumparampil, Nithin; Srivastava, Abhishek; Khani, Francesca; Robinson, Brian D; Gumpeni, Naveen; Shevchuk, Maria M; Durand, Matthieu; Sooriakumaran, Prasanna; Li, Jinyi; Leung, Robert; Peyser, Alexandra; Gruschow, Siobhan; Asija, Vinita; Harneja, Niyati

    2013-06-01

    To report our unique approach for individualizing robotic prostate cancer surgery by risk stratification and sub classification of the periprostatic space into 4 distinct compartments, and thus performing 4 precise different grades of nerve sparing based on neurosurgical principles and to present updated potency and continence outcomes data of patients undergoing robotic-assisted laparoscopic prostatectomy (RALP) using our risk-stratified approach based on layers of periprostatic fascial dissection. (1) Between January 2005 and December 2010, 2,536 men underwent RALP by a single surgeon at our institution. (2) Included patients were those with ≥ 1-year follow-up and were preoperatively continent and potent, defined as having a SHIM questionnaire score of >21; thus, the final number of patient in the study cohort was 1,335. (3) Postoperative potency was defined as the ability to have successful intercourse (score of ≥ 4 on question 2 of the SHIM); continence was defined as the use of no pads per 24 h. (1) The potency and continence for NS grades 1, 2, 3, and 4 were found to be 90.6, 76.2, 60.5, and 57.1 % (P < 0.001) and 98, 93.2, 90.1, and 88.9 % (P < 0.001), respectively. (2) The overall PSM rates for patients with NS grades 1, 2, 3, and 4 were 10.5, 7, 5.8, and 4.8 %, respectively (P = 0.064). The study found a correlation between risk-stratified grades of NS technique and continence and potency. Patients with lesser grades of NS had higher rates of potency and continence.

  1. A systematic review and cost analysis of robot-assisted hysterectomy in malignant and benign conditions.

    PubMed

    Tapper, Anna-Maija; Hannola, Mikko; Zeitlin, Rainer; Isojärvi, Jaana; Sintonen, Harri; Ikonen, Tuija S

    2014-06-01

    In order to assess the effectiveness and costs of robot-assisted hysterectomy compared with conventional techniques we reviewed the literature separately for benign and malignant conditions, and conducted a cost analysis for different techniques of hysterectomy from a hospital economic database. Unlimited systematic literature search of Medline, Cochrane and CRD databases produced only two randomized trials, both for benign conditions. For the outcome assessment, data from two HTA reports, one systematic review, and 16 original articles were extracted and analyzed. Furthermore, one cost modelling and 13 original cost studies were analyzed. In malignant conditions, less blood loss, fewer complications and a shorter hospital stay were considered as the main advantages of robot-assisted surgery, like any mini-invasive technique when compared to open surgery. There were no significant differences between the techniques regarding oncological outcomes. When compared to laparoscopic hysterectomy, the main benefit of robot-assistance was a shorter learning curve associated with fewer conversions but the length of robotic operation was often longer. In benign conditions, no clinically significant differences were reported and vaginal hysterectomy was considered the optimal choice when feasible. According to Finnish data, the costs of robot-assisted hysterectomies were 1.5-3 times higher than the costs of conventional techniques. In benign conditions the difference in cost was highest. Because of expensive disposable supplies, unit costs were high regardless of the annual number of robotic operations. Hence, in the current distribution of cost pattern, economical effectiveness cannot be markedly improved by increasing the volume of robotic surgery. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Using robot fully assisted functional movements in upper-limb rehabilitation of chronic stroke patients: preliminary results.

    PubMed

    Caimmi, Marco; Chiavenna, Andrea; Scano, Alessandro; Gasperini, Giulio; Giovanzana, Chiara; Molinari Tosatti, Lorenzo; Molteni, Franco

    2017-06-01

    Robotic rehabilitation is promising to promote function in stroke patients. The assist as needed training paradigm has shown to stimulate neuroplasticity but often cannot be used because stroke patients are too impaired to actively control the robot against gravity. To verify whether a rehabilitation intervention based on robot fully assisted reaching against gravity (RCH) and hand-to-mouth (HTM) can promote upper-limb function in chronic stroke. Cohort study. Chronic stroke outpatients referring to the robotic rehabilitation lab of a rehabilitation centre. Ten chronic stroke patients with mild to moderate upper-limb hemiparesis. Patients underwent 12 sessions (3 per week) of robotic treatment using an end-effector robot Every session consisted of 20 minutes each of RCH and HtM; movements were fully assisted, but patients were asked to try to actively participate. The Fugl-Meyer Assessment (FMA) was the primary outcome measure; Medical Research Council and Modified Ashworth Scale were the secondary outcome measures. All patients, but one, show functional improvements (FMA section A-D, mean increment 7.2±3.9 points, P<0.008). This preliminary study shows that a robotic intervention based on functional movements, fully assisted, can be effective in promoting function in chronic stroke patients. These results are promising considering the short time of the intervention (1 month) and the time from the stroke event, which was large (27±20 months). A larger study, comprehensive of objective instrumental measures, is necessary to confirm the results. This intervention could be extended even to subacute stroke and other neurological disorders.

  3. Cost-effectiveness of open versus laparoscopic versus robotic-assisted laparoscopic cystectomy and urinary diversion.

    PubMed

    Zehnder, Pascal; Gill, Inderbir S

    2011-09-01

    To provide insight into the recently published cost comparisons in the context of open, laparoscopic, and robotic-assisted laparoscopic radical cystectomy and to demonstrate the complexity of such economic analyses. Most economic evaluations are from a hospital perspective and summarize short-term perioperative therapeutic costs. However, the contributing factors (e.g. study design, included variables, robotic amortization plan, supply contract, surgical volume, surgeons' experience, etc.) vary substantially between the institutions. In addition, a real cost-effective analysis considering cost per quality-adjusted life-year gained is not feasible because of the lack of long-term oncologic and functional outcome data with the robotic procedure. On the basis of a modeled cost analysis using results from published series, robotic-assisted cystectomy was - with few exceptions - found to be more expensive when compared with the open approach. Immediate costs are affected most by operative time, followed by length of hospital stay, robotic supply, case volume, robotic cost, and transfusion rate. Any complication substantially impacts overall costs. Economic cost evaluations are complex analyses influenced by numerous factors that hardly allow an interinstitutional comparison. Robotic-assisted cystectomy is constantly refined with many institutions being somewhere on their learning curve. Transparent reports of oncologic and functional outcome data from centers of expertise applying standardized methods will help to properly analyze the real long-term benefits of robotic surgery and successor technologies and prevent us from becoming slaves of successful marketing strategies.

  4. A multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors: a preclinical study.

    PubMed

    Li, Dongrui; Cheng, Zhigang; Chen, Gang; Liu, Fangyi; Wu, Wenbo; Yu, Jie; Gu, Ying; Liu, Fengyong; Ren, Chao; Liang, Ping

    2018-04-03

    To test the accuracy and efficacy of the multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors in phantom and animal models. To evaluate and compare the influences of intervention experience on robot-assisted and ultrasound-controlled ablation procedures. Accuracy tests on rigid body/phantom model with a respiratory movement simulation device and microwave ablation tests on porcine liver tumor/rabbit liver cancer were performed with the robot we designed or with the traditional ultrasound-guidance by physicians with or without intervention experience. In the accuracy tests performed by the physicians without intervention experience, the insertion accuracy and efficiency of robot-assisted group was higher than those of ultrasound-guided group with statistically significant differences. In the microwave ablation tests performed by the physicians without intervention experience, better complete ablation rate was achieved when applying the robot. In the microwave ablation tests performed by the physicians with intervention experience, there was no statistically significant difference of the insertion number and total ablation time between the robot-assisted group and the ultrasound-controlled group. The evaluation by the NASA-TLX suggested that the robot-assisted insertion and microwave ablation process performed by physicians with or without experience were more comfortable. The multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors could increase the insertion accuracy and ablation efficacy, and minimize the influence of the physicians' experience. The ablation procedure could be more comfortable with less stress with the application of the robot.

  5. The affordability of minimally invasive procedures in major lung resection: a prospective study.

    PubMed

    Gondé, Henri; Laurent, Marc; Gillibert, André; Sarsam, Omar-Matthieu; Varin, Rémi; Grimandi, Gaël; Peillon, Christophe; Baste, Jean-Marc

    2017-09-01

    Minimally invasive procedures are used for the surgical treatment of lung cancer. Two techniques are proposed: video-assisted thoracic surgery or robotic-assisted thoracic surgery. Our goal was to study the economic impact of our long-standing program for minimally invasive procedures for major lung resection. We conducted a single-centre, 1-year prospective cost study. Patients who underwent lobectomy or segmentectomy were included. Patient characteristics and perioperative outcomes were collected. Medical supply expenses based on the microcosting method and capital depreciation were estimated. Total cost was evaluated using a national French database. One hundred twelve patients were included, 57 with and 55 without robotic assistance. More segmentectomies were performed with robotic assistance. The median length of stay was 5 days for robotic-assisted and 6 days for video-assisted procedures (P = 0.13). The duration of median chest drains (4 days, P = 0.36) and of operating room time (255 min, P = 0.55) was not significantly different between the groups. The overall conversion rate to thoracotomy was 9%, significantly higher in the video-assisted group than in the robotic group (16% vs 2%, P = 0.008). No difference was observed in postoperative complications. The cost of most robotic-assisted procedures ranged from €10 000 to €12 000 (median €10 972) and that of most video-assisted procedures ranged from €8 000 to €10 000 (median €9 637) (P = 0.007); median medical supply expenses were €3 236 and €2 818, respectively (P = 0.004). The overall mean cost of minimally invasive techniques (€11 759) was significantly lower than the mean French cost of lung resection surgical procedures (€13 424) (P = 0.001). The cost at our centre of performing minimally invasive surgical procedures appeared lower than the cost nationwide. Robotic-assisted thoracic surgery demonstrated acceptable additional costs for a long-standing program. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Optimisation of fluorescence guidance during robot-assisted laparoscopic sentinel node biopsy for prostate cancer.

    PubMed

    KleinJan, Gijs H; van den Berg, Nynke S; Brouwer, Oscar R; de Jong, Jeroen; Acar, Cenk; Wit, Esther M; Vegt, Erik; van der Noort, Vincent; Valdés Olmos, Renato A; van Leeuwen, Fijs W B; van der Poel, Henk G

    2014-12-01

    The hybrid tracer was introduced to complement intraoperative radiotracing towards the sentinel nodes (SNs) with fluorescence guidance. Improve in vivo fluorescence-based SN identification for prostate cancer by optimising hybrid tracer preparation, injection technique, and fluorescence imaging hardware. Forty patients with a Briganti nomogram-based risk >10% of lymph node (LN) metastases were included. After intraprostatic tracer injection, SN mapping was performed (lymphoscintigraphy and single-photon emission computed tomography with computed tomography (SPECT-CT)). In groups 1 and 2, SNs were pursued intraoperatively using a laparoscopic gamma probe followed by fluorescence imaging (FI). In group 3, SNs were initially located via FI. Compared with group 1, in groups 2 and 3, a new tracer formulation was introduced that had a reduced total injected volume (2.0 ml vs. 3.2 ml) but increased particle concentration. For groups 1 and 2, the Tricam SLII with D-Light C laparoscopic FI (LFI) system was used. In group 3, the LFI system was upgraded to an Image 1 HUB HD with D-Light P system. Hybrid tracer-based SN biopsy, extended pelvic lymph node dissection, and robot-assisted radical prostatectomy. Number and location of the preoperatively identified SNs, in vivo fluorescence-based SN identification rate, tumour status of SNs and LNs, postoperative complications, and biochemical recurrence (BCR). Mean fluorescence-based SN identification improved from 63.7% (group 1) to 85.2% and 93.5% for groups 2 and 3, respectively (p=0.012). No differences in postoperative complications were found. BCR occurred in three pN0 patients. Stepwise optimisation of the hybrid tracer formulation and the LFI system led to a significant improvement in fluorescence-assisted SN identification. Preoperative SPECT-CT remained essential for guiding intraoperative SN localisation. Intraoperative fluorescence-based SN visualisation can be improved by enhancing the hybrid tracer formulation and laparoscopic fluorescence imaging system. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  7. Planning actions in robot automated operations

    NASA Technical Reports Server (NTRS)

    Das, A.

    1988-01-01

    Action planning in robot automated operations requires intelligent task level programming. Invoking intelligence necessiates a typical blackboard based architecture, where, a plan is a vector between the start frame and the goal frame. This vector is composed of partially ordered bases. A partial ordering of bases presents good and bad sides in action planning. Partial ordering demands the use of a temporal data base management system.

  8. Robot-assisted bronchoplasty using continuous barbed sutures.

    PubMed

    Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno; Baste, Jean-Marc

    2018-01-01

    We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors.

  9. Long-term penile morphometric alterations in patients treated with robot-assisted versus open radical prostatectomy.

    PubMed

    Capogrosso, P; Ventimiglia, E; Cazzaniga, W; Stabile, A; Pederzoli, F; Boeri, L; Gandaglia, G; Dehò, F; Briganti, A; Montorsi, F; Salonia, A

    2018-01-01

    Neglected side effects after radical prostatectomy have been previously reported. In this context, the prevalence of penile morphometric alterations has never been assessed in robot-assisted radical prostatectomy series. We aimed to assess prevalence of and predictors of penile morphometric alterations (i.e. penile shortening or penile morphometric deformation) at long-term follow-up in patients submitted to either robot-assisted (robot-assisted radical prostatectomy) or open radical prostatectomy. Sexually active patients after either robot-assisted radical prostatectomy or open radical prostatectomy prospectively completed a 28-item questionnaire, with sensitive issues regarding sexual function, namely orgasmic functioning, climacturia and changes in morphometric characteristics of the penis. Only patients with a post-operative follow-up ≥ 24 months were included. Patients submitted to either adjuvant or salvage therapies or those who refused to comprehensively complete the questionnaire were excluded from the analyses. A propensity-score matching analysis was implemented to control for baseline differences between groups. Logistic regression models tested potential predictors of penile morphometric alterations at long-term post-operative follow-up. Overall, 67 (50%) and 67 (50%) patients were included after open radical prostatectomy or robot-assisted radical prostatectomy, respectively. Self-rated post-operative penile shortening and penile morphometric deformation were reported by 75 (56%) and 29 (22.8%) patients, respectively. Rates of penile shortening and penile morphometric deformation were not different after open radical prostatectomy and robot-assisted radical prostatectomy [all p > 0.5]. At univariable analysis, self-reported penile morphometric alterations (either penile shortening or penile morphometric deformation) were significantly associated with baseline international index of erectile function-erectile function scores, body mass index, post-operative erectile function recovery, year of surgery and type of surgery (all p < 0.05). At multivariable analysis, robot-assisted radical prostatectomy was independently associated with a lower risk of post-operative penile morphometric alterations (OR: 0.38; 95% CI: 0.16-0.93). Self-perceived penile morphometric alterations were reported in one of two patients after radical prostatectomy at long-term follow-up, with open surgery associated with a potential higher risk of this self-perception. © 2017 American Society of Andrology and European Academy of Andrology.

  10. Report on First International Workshop on Robotic Surgery in Thoracic Oncology.

    PubMed

    Veronesi, Giulia; Cerfolio, Robert; Cingolani, Roberto; Rueckert, Jens C; Soler, Luc; Toker, Alper; Cariboni, Umberto; Bottoni, Edoardo; Fumagalli, Uberto; Melfi, Franca; Milli, Carlo; Novellis, Pierluigi; Voulaz, Emanuele; Alloisio, Marco

    2016-01-01

    A workshop of experts from France, Germany, Italy, and the United States took place at Humanitas Research Hospital Milan, Italy, on February 10 and 11, 2016, to examine techniques for and applications of robotic surgery to thoracic oncology. The main topics of presentation and discussion were robotic surgery for lung resection; robot-assisted thymectomy; minimally invasive surgery for esophageal cancer; new developments in computer-assisted surgery and medical applications of robots; the challenge of costs; and future clinical research in robotic thoracic surgery. The following article summarizes the main contributions to the workshop. The Workshop consensus was that since video-assisted thoracoscopic surgery (VATS) is becoming the mainstream approach to resectable lung cancer in North America and Europe, robotic surgery for thoracic oncology is likely to be embraced by an increasing numbers of thoracic surgeons, since it has technical advantages over VATS, including intuitive movements, tremor filtration, more degrees of manipulative freedom, motion scaling, and high-definition stereoscopic vision. These advantages may make robotic surgery more accessible than VATS to trainees and experienced surgeons and also lead to expanded indications. However, the high costs of robotic surgery and absence of tactile feedback remain obstacles to widespread dissemination. A prospective multicentric randomized trial (NCT02804893) to compare robotic and VATS approaches to stages I and II lung cancer will start shortly.

  11. Randomized, sham-controlled trial based on transcranial direct current stimulation and wrist robot-assisted integrated treatment on subacute stroke patients: Intermediate results.

    PubMed

    Mazzoleni, Stefano; Tran, Vi Do; Iardella, Laura; Dario, Paolo; Posteraro, Federico

    2017-07-01

    The main goal of this study is to analyse the effects of combined transcranial direct current stimulation (tDCS) and wrist robot-assisted therapy in subacute stroke patients. Twenty-four patients were included in this study and randomly assigned to the experimental (EG) or control group (CG). All participants performed wrist robot-assisted training a) in conjunction with tDCS (real stimulation for patients in EG) or b) without tDCS (sham stimulation for patients in CG). Clinical scales and kinematic parameters recorded by the robot were used for the assessment. Clinical outcome measures show a significant decrease in motor impairment after the treatment in both groups. Kinematic data show several significant improvements after the integrated therapy in both groups. However, no significant differences in both clinical outcome measures and kinematic parameters was found between two groups. The potential advantages of combined tDCS and wrist robot-assisted therapy in subacute stroke patients are still unclear.

  12. Robotic-assisted percutaneous coronary intervention--filling an unmet need.

    PubMed

    Carrozza, Joseph P

    2012-02-01

    Percutaneous coronary intervention (PCI) has undergone a remarkable evolution over the past 25 years. Initially, the procedure was limited to relatively straightforward lesions and was associated with significant risk and unpredictable long-term efficacy. With the incorporation of new technologies such as stents, the safety and efficacy of the procedure has improved dramatically. However, the fundamental way in which the procedure is performed has changed little since the time of Gruntzig's first successful case. Cumulative exposure to ionizing radiation, orthopedic injuries resulting from wearing shielding aprons, and fatigue from standing for hours at the table have made the catheterization laboratory a "high-risk workplace" for the interventional cardiologist. Robotic-assisted PCI was developed to allow the operator to precisely manipulate angioplasty guidewires, balloons, and stents from a radiation-shielded cockpit. A small first-in-man study demonstrated that PCI can be performed with robotic assistance. The pivotal Percutaneous Robotically Enhanced Coronary Intervention Study trial is currently enrolling patients and evaluating the safety and efficacy of the CorPath® robotically assisted PCI system.

  13. Integrated Planning for Telepresence With Time Delays

    NASA Technical Reports Server (NTRS)

    Johnston, Mark; Rabe, Kenneth

    2009-01-01

    A conceptual "intelligent assistant" and an artificial-intelligence computer program that implements the intelligent assistant have been developed to improve control exerted by a human supervisor over a robot that is so distant that communication between the human and the robot involves significant signal-propagation delays. The goal of the effort is not only to help the human supervisor monitor and control the state of the robot, but also to improve the efficiency of the robot by allowing the supervisor to "work ahead". The intelligent assistant is an integrated combination of an artificial-intelligence planner and a monitor of states of both the human supervisor and the remote robot. The novelty of the system lies in the way it uses the planner to reason about the states at both ends of the time delay. The purpose served by the assistant is to provide advice to the human supervisor about current and future activities, derived from a sequence of high-level goals to be achieved.

  14. Multipurpose surgical robot as a laparoscope assistant.

    PubMed

    Nelson, Carl A; Zhang, Xiaoli; Shah, Bhavin C; Goede, Matthew R; Oleynikov, Dmitry

    2010-07-01

    This study demonstrates the effectiveness of a new, compact surgical robot at improving laparoscope guidance. Currently, the assistant guiding the laparoscope camera tends to be less experienced and requires physical and verbal direction from the surgeon. Human guidance has disadvantages of fatigue and shakiness leading to inconsistency in the field of view. This study investigates whether replacing the assistant with a compact robot can improve the stability of the surgeon's field of view and also reduce crowding at the operating table. A compact robot based on a bevel-geared "spherical mechanism" with 4 degrees of freedom and capable of full dexterity through a 15-mm port was designed and built. The robot was mounted on the standard railing of the operating table and used to manipulate a laparoscope through a supraumbilical port in a porcine model via a joystick controlled externally by a surgeon. The process was videotaped externally via digital video recorder and internally via laparoscope. Robot position data were also recorded within the robot's motion control software. The robot effectively manipulated the laparoscope in all directions to provide a clear and consistent view of liver, small intestine, and spleen. Its range of motion was commensurate with typical motions executed by a human assistant and was well controlled with the joystick. Qualitative analysis of the video suggested that this method of laparoscope guidance provides highly stable imaging during laparoscopic surgery, which was confirmed by robot position data. Because the robot was table-mounted and compact in design, it increased standing room around the operation table and did not interfere with the workspace of other surgical instruments. The study results also suggest that this robotic method may be combined with flexible endoscopes for highly dexterous visualization with more degrees of freedom.

  15. Designing a social and assistive robot for seniors.

    PubMed

    Eftring, H; Frennert, S

    2016-06-01

    The development of social assistive robots is an approach with the intention of preventing and detecting falls among seniors. There is a need for a relatively low-cost mobile robot with an arm and a gripper which is small enough to navigate through private homes. User requirements of a social assistive robot were collected using workshops, a questionnaire and interviews. Two prototype versions of a robot were designed, developed and tested by senior citizens (n = 49) in laboratory trials for 2 h each and in the private homes of elderly persons (n = 18) for 3 weeks each. The user requirement analysis resulted in a specification of tasks the robot should be able to do to prevent and detect falls. It was a challenge but possible to design and develop a robot where both the senior and the robot arm could reach the necessary interaction points of the robot. The seniors experienced the robot as happy and friendly. They wanted the robot to be narrower so it could pass through narrow passages in the home and they also wanted it to be able to pass over thresholds without using ramps and to drive over carpets. User trials in seniors' homes are very important to acquire relevant knowledge for developing robots that can handle real life situations in the domestic environment. Very high reliability of a robot is needed to get feedback about how seniors experience the overall behavior of the robot and to find out if the robot could reduce falls and improve the feeling of security for seniors living alone.

  16. Introduction of a new laser-scalpel for partial kidney resection based on 1.94 micrometer fiber laser system: initial in vivo-data

    NASA Astrophysics Data System (ADS)

    Tedsen, Sönke; Theisen-Kunde, Dirk; Doehn, Christian; Kausch, Ingo; Jocham, Dieter

    2009-02-01

    The technique of nephron sparing surgery has matured significantly over the past decade and is emerging as an oncologically sound procedure for the management of renal tumors. Methods of tumor excision as well as parenchymal reconstruction in a hemostaticallly controlled field have evolved to make this procedure safer. In an attempt to find an improoved hemostatic cutting instrument we developed a 1.94 micrometer Laser-Scalpel system in a porcine model. We evaluated data for partial porcine kidney resection performed by a 1.94 micrometer Laser-Scalpel and compared the data to those of a standard HF- (High- Frequency) dissection device. In 12 pigs general anesthesia and a median laparotomy was performed to expose both kidneys. In each pig one kidney was partially resected with the Laser-Scalpel and the other side with the HF-dissection device. The first 6 pigs were euthanized immediately after the procedure. The following 6 pigs were allowed to recover and underwent 2-3 weeks later euthanasia. The final evaluation data included total resection time, blood loss, mass of dissected tissue, total ischemic time and histological examination. Mean resected kidney tissue mass was 4.75 g with the laser system and 5.57 g for the HF-dissector, respectively. Mean estimated blood loss was 22 ml for the Laser- Scalpel and 78.2 ml for the HF-dissection device. Resection time was 9.45 min for the Laser-scalpel compared to 10.16 min. No complications, specifically no postoperative bleeding, occured in any of the animals. Histological evaluation with H&E staining showed a carbonized zone of about 0.57 mm directly at the dissected edge followed by a thermal damaged zone of about 1.25 mm in width. Thereafter healthy tissue was found in all histological samples. Partial kidney resection was easily and fast performed by the use of a 1.94 micrometer Laser-Scalpel system. Hemostasis was highly sufficient, so blood loss was minimal compared to conventional HF-dissection device. Therefore the 1.94 micrometer Laser-Scalpel system is a very promising dissection device for urological surgery.

  17. Survey on Robot-Assisted Surgical Techniques Utilization in US Pediatric Surgery Fellowships.

    PubMed

    Maizlin, Ilan I; Shroyer, Michelle C; Yu, David C; Martin, Colin A; Chen, Mike K; Russell, Robert T

    2017-02-01

    Robotic technology has transformed both practice and education in many adult surgical specialties; no standardized training guidelines in pediatric surgery currently exist. The purpose of our study was to assess the prevalence of robotic procedures and extent of robotic surgery education in US pediatric surgery fellowships. A deidentified survey measured utilization of the robot, perception on the utility of the robot, and its incorporation in training among the program directors of Accreditation Council for Graduate Medical Education (ACGME) pediatric surgery fellowships in the United States. Forty-one of the 47 fellowship programs (87%) responded to the survey. While 67% of respondents indicated the presence of a robot in their facility, only 26% reported its utilizing in their surgical practice. Among programs not utilizing the robot, most common reasons provided were lack of clear supportive evidence, increased intraoperative time, and incompatibility of instrument size to pediatric patients. While 58% of program directors believe that there is a future role for robotic surgery in children, only 18% indicated that robotic training should play a part in pediatric surgery education. Consequently, while over 66% of survey respondents received training in robot-assisted surgical technique, only 29% of fellows receive robot-assisted training during their fellowship. A majority of fellowships have access to a robot, but few utilize the technology in their current practice or as part of training. Further investigation is required into both the technology's potential benefits in the pediatric population and its role in pediatric surgery training.

  18. A development of assistant surgical robot system based on surgical-operation-by-wire and hands-on-throttle-and-stick.

    PubMed

    Kim, Myungjoon; Lee, Chiwon; Park, Woo Jung; Suh, Yun Suhk; Yang, Han Kwang; Kim, H Jin; Kim, Sungwan

    2016-05-20

    Robot-assisted laparoscopic surgery offers several advantages compared with open surgery and conventional minimally invasive surgery. However, one issue that needs to be resolved is a collision between the robot arm and the assistant instrument. This is mostly caused by miscommunication between the surgeon and the assistant. To resolve this limitation, an assistant surgical robot system that can be simultaneously manipulated via a wireless controller is proposed to allow the surgeon to control the assistant instrument. The system comprises two novel master interfaces (NMIs), a surgical instrument with a gripper actuated by a micromotor, and 6-axis robot arm. Two NMIs are attached to master tool manipulators of da Vinci research kit (dVRK) to control the proposed system simultaneously with patient side manipulators of dVRK. The developments of the surgical instrument and NMI are based on surgical-operation-by-wire concept and hands-on-throttle-and-stick concept from the earlier research, respectively. Tests for checking the accuracy, latency, and power consumption of the NMI are performed. The gripping force, reaction time, and durability are assessed to validate the surgical instrument. The workspace is calculated for estimating the clinical applicability. A simple peg task using the fundamentals of laparoscopic surgery board and an in vitro test are executed with three novice volunteers. The NMI was operated for 185 min and reflected the surgeon's decision successfully with a mean latency of 132 ms. The gripping force of the surgical instrument was comparable to that of conventional systems and was consistent even after 1000 times of gripping motion. The reaction time was 0.4 s. The workspace was calculated to be 8397.4 cm(3). Recruited volunteers were able to execute the simple peg task within the cut-off time and successfully performed the in vitro test without any collision. Various experiments were conducted and it is verified that the proposed assistant surgical robot system enables collision-free and simultaneous operation of the dVRK's robot arm and the proposed assistant robot arm. The workspace is appropriate for the performance of various kinds of surgeries. Therefore, the proposed system is expected to provide higher safety and effectiveness for the current surgical robot system.

  19. Multi-institutional analysis of robotic partial nephrectomy for hilar versus nonhilar lesions in 446 consecutive cases.

    PubMed

    Dulabon, Lori M; Kaouk, Jihad H; Haber, Georges-Pascal; Berkman, Douglas S; Rogers, Craig G; Petros, Firas; Bhayani, Sam B; Stifelman, Michael D

    2011-03-01

    Minimally invasive approaches to partial nephrectomy have been rapidly gaining popularity but require advanced laparoscopic surgical skills. Renal hilar tumors, due to their anatomic location, pose additional technical challenges to the operating surgeon. We compared the outcomes of robot-assisted partial nephrectomy (RPN) for hilar and nonhilar tumors in our large multicenter contemporary series of patients. We retrospectively reviewed prospectively collected data on 446 consecutive patients who underwent RPN by renal surgeons experienced in minimally invasive techniques at four academic institutions from June 2006 to March 2010. Patients were stratified into two groups: those with hilar lesions and those with nonhilar lesions. Patient demographics, operative outcomes, and postoperative outcomes, including oncologic outcomes, were recorded. Forty-one patients (9%) had hilar renal masses; 405 patients (91%) had nonhilar masses. There was no statistical differences in patient demographics except for larger median tumor size in the hilar cohort (3.2 cm vs 2.6 cm; p=0.001). The only significant difference in operative outcomes was an increase in warm ischemia times for the hilar group versus the nonhilar group (26.3±7.4 min vs 19.6±10.0 min; p=<0.0001). There were no differences in postoperative outcomes; however, there was a trend for increased risk of malignancy and higher stage tumors in the hilar lesion group. Final pathologic margin status was similar in both groups. Only one patient in the nonhilar group had evidence of recurrence at 21 mo. The study was limited by the lack of standard anatomic classification of renal tumors and the potential influence of the surgeons' prior robotic experience. The data represent the largest series of its kind and strongly suggest that RPN is a safe, effective, and feasible option for the minimally invasive approach to renal hilar tumors with no increased risk of adverse outcomes compared with nonhilar tumors in the hands of experienced robotic surgeons. Copyright © 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  20. Da Vinci Xi Robot–Assisted Penetrating Keratoplasty

    PubMed Central

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-01-01

    Purpose This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Methods Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Results Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5–61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. Conclusions We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Translational Relevance Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use. PMID:28660096

  1. Assist-as-needed robotic trainer based on reinforcement learning and its application to dart-throwing.

    PubMed

    Obayashi, Chihiro; Tamei, Tomoya; Shibata, Tomohiro

    2014-05-01

    This paper proposes a novel robotic trainer for motor skill learning. It is user-adaptive inspired by the assist-as-needed principle well known in the field of physical therapy. Most previous studies in the field of the robotic assistance of motor skill learning have used predetermined desired trajectories, and it has not been examined intensively whether these trajectories were optimal for each user. Furthermore, the guidance hypothesis states that humans tend to rely too much on external assistive feedback, resulting in interference with the internal feedback necessary for motor skill learning. A few studies have proposed a system that adjusts its assistive strength according to the user's performance in order to prevent the user from relying too much on the robotic assistance. There are, however, problems in these studies, in that a physical model of the user's motor system is required, which is inherently difficult to construct. In this paper, we propose a framework for a robotic trainer that is user-adaptive and that neither requires a specific desired trajectory nor a physical model of the user's motor system, and we achieve this using model-free reinforcement learning. We chose dart-throwing as an example motor-learning task as it is one of the simplest throwing tasks, and its performance can easily be and quantitatively measured. Training experiments with novices, aiming at maximizing the score with the darts and minimizing the physical robotic assistance, demonstrate the feasibility and plausibility of the proposed framework. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Assessment of Perceived Attractiveness, Usability, and Societal Impact of a Multimodal Robotic Assistant for Aging Patients With Memory Impairments.

    PubMed

    Gerłowska, Justyna; Skrobas, Urszula; Grabowska-Aleksandrowicz, Katarzyna; Korchut, Agnieszka; Szklener, Sebastian; Szczęśniak-Stańczyk, Dorota; Tzovaras, Dimitrios; Rejdak, Konrad

    2018-01-01

    The aim of the present study is to present the results of the assessment of clinical application of the robotic assistant for patients suffering from mild cognitive impairments (MCI) and Alzheimer Disease (AD). The human-robot interaction (HRI) evaluation approach taken within the study is a novelty in the field of social robotics. The proposed assessment of the robotic functionalities are based on end-user perception of attractiveness, usability and potential societal impact of the device. The methods of evaluation applied consist of User Experience Questionnaire (UEQ), AttrakDiff and the societal impact inventory tailored for the project purposes. The prototype version of the Robotic Assistant for MCI patients at Home (RAMCIP) was tested in a semi-controlled environment at the Department of Neurology (Lublin, Poland). Eighteen elderly participants, 10 healthy and 8 MCI, performed everyday tasks and functions facilitated by RAMCIP. The tasks consisted of semi-structuralized scenarios like: medication intake, hazardous events prevention, and social interaction. No differences between the groups of subjects were observed in terms of perceived attractiveness, usability nor-societal impact of the device. The robotic assistant societal impact and attractiveness were highly assessed. The usability of the device was reported as neutral due to the short time of interaction.

  3. Assessment of Perceived Attractiveness, Usability, and Societal Impact of a Multimodal Robotic Assistant for Aging Patients With Memory Impairments

    PubMed Central

    Gerłowska, Justyna; Skrobas, Urszula; Grabowska-Aleksandrowicz, Katarzyna; Korchut, Agnieszka; Szklener, Sebastian; Szczęśniak-Stańczyk, Dorota; Tzovaras, Dimitrios; Rejdak, Konrad

    2018-01-01

    The aim of the present study is to present the results of the assessment of clinical application of the robotic assistant for patients suffering from mild cognitive impairments (MCI) and Alzheimer Disease (AD). The human-robot interaction (HRI) evaluation approach taken within the study is a novelty in the field of social robotics. The proposed assessment of the robotic functionalities are based on end-user perception of attractiveness, usability and potential societal impact of the device. The methods of evaluation applied consist of User Experience Questionnaire (UEQ), AttrakDiff and the societal impact inventory tailored for the project purposes. The prototype version of the Robotic Assistant for MCI patients at Home (RAMCIP) was tested in a semi-controlled environment at the Department of Neurology (Lublin, Poland). Eighteen elderly participants, 10 healthy and 8 MCI, performed everyday tasks and functions facilitated by RAMCIP. The tasks consisted of semi-structuralized scenarios like: medication intake, hazardous events prevention, and social interaction. No differences between the groups of subjects were observed in terms of perceived attractiveness, usability nor-societal impact of the device. The robotic assistant societal impact and attractiveness were highly assessed. The usability of the device was reported as neutral due to the short time of interaction.

  4. Using a Harmonic Scalpel "Drilling and Clamping" Method to Implement Zero Ischemic Robotic-assisted Partial Nephrectomy: An Observation Case Report Study.

    PubMed

    Hou, Chen-Pang; Lin, Yu-Hsiang; Hsu, Yu-Chao; Chen, Chien-Lun; Chang, Phei-Lang; Tsui, Ke-Hung

    2016-01-01

    Robot-assisted partial nephrectomy (RAPN) has gradually become a popular minimally invasive nephron-sparing surgical option for small renal tumors. Ischemic injury should be minimized because it impacts renal function outcomes following partial nephrectomy. Herein, the authors detail the technique and present initial perioperative outcomes of our novel harmonic scalpel "drilling and clamping" method to implement zero-ischemic RAPN. The authors prospectively collected baseline and perioperative data of patients who underwent zero ischemic RAPN performed by our harmonic scalpel "drilling and clamping" method. From April 2012 to December 2014, a total of 19 consecutive zero ischemic RAPN procedures were performed by a single surgeon. For 18 of the 19 patients, RAPN using our harmonic scalpel "Drilling and Clamping" method was successfully completed without the need for hilar clamping. The median tumor size was 3.4 cm (range: 1.8-6.2); operative time was 3.2 hours (range: 1.9-4.5); blood loss was 100 mL (range: 30-950); and postoperative hospital stay was 4 days (3-26). One patient required intraoperative blood transfusion. Two patients had intra or postoperative complications: 1 was converted to traditional laparotomy because of massive bleeding, whereas another had postoperative stress ulcer. Pathology confirmed renal cell carcinoma in 13 patients (63.2%), angiomyolipoma in 6 patients: (31.5%), and oncocytoma in 1 patient (5.3%). Mean pre- and postoperative serum creatinine (0.82 mg/dL and 0.85 mg/dL, respectively), estimated glomerular filtration rate (84.12 and 82.18, respectively), and hemoglobin (13.27 g/dL and 12.71 g/dL, respectively) were comparable. The authors present a novel zero-ischemic technique for RAPN. They believe that this technique is feasible and reproducible.

  5. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    PubMed

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  6. Control strategies for effective robot assisted gait rehabilitation: the state of art and future prospects.

    PubMed

    Cao, Jinghui; Xie, Sheng Quan; Das, Raj; Zhu, Guo L

    2014-12-01

    A large number of gait rehabilitation robots, together with a variety of control strategies, have been developed and evaluated during the last decade. Initially, control strategies applied to rehabilitation robots were adapted from those applied to traditional industrial robots. However, these strategies cannot optimise effectiveness of gait rehabilitation. As a result, researchers have been investigating control strategies tailored for the needs of rehabilitation. Among these control strategies, assisted-as-needed (AAN) control is one of the most popular research topics in this field. AAN training strategies have gained the theoretical and practical evidence based backup from motor learning principles and clinical studies. Various approaches to AAN training have been proposed and investigated by research groups all around the world. This article presents a review on control algorithms of gait rehabilitation robots to summarise related knowledge and investigate potential trends of development. There are existing review papers on control strategies of rehabilitation robots. The review by Marchal-Crespo and Reinkensmeyer (2009) had a broad cover of control strategies of all kinds of rehabilitation robots. Hussain et al. (2011) had specifically focused on treadmill gait training robots and covered a limited number of control implementations on them. This review article encompasses more detailed information on control strategies for robot assisted gait rehabilitation, but is not limited to treadmill based training. It also investigates the potential to further develop assist-as-needed gait training based on assessments of patients' ability. In this paper, control strategies are generally divided into the trajectory tracking control and AAN control. The review covers these two basic categories, as well as other control algorithm and technologies derived from them, such as biofeedback control. Assessments on human gait ability are also included to investigate how to further develop implementations based on assist-as-needed concept. For the consideration of effectiveness, clinical studies on robotic gait rehabilitation are reviewed and analysed from the viewpoint of control algorithm. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Feasibility of Synergy-Based Exoskeleton Robot Control in Hemiplegia.

    PubMed

    Hassan, Modar; Kadone, Hideki; Ueno, Tomoyuki; Hada, Yasushi; Sankai, Yoshiyuki; Suzuki, Kenji

    2018-06-01

    Here, we present a study on exoskeleton robot control based on inter-limb locomotor synergies using a robot control method developed to target hemiparesis. The robot control is based on inter-limb locomotor synergies and kinesiological information from the non-paretic leg and a walking aid cane to generate motion patterns for the assisted leg. The developed synergy-based system was tested against an autonomous robot control system in five patients with hemiparesis and varying locomotor abilities. Three of the participants were able to walk using the robot. Results from these participants showed an improved spatial symmetry ratio and more consistent step length with the synergy-based method compared with that for the autonomous method, while the increase in the range of motion for the assisted joints was larger with the autonomous system. The kinematic synergy distribution of the participants walking without the robot suggests a relationship between each participant's synergy distribution and his/her ability to control the robot: participants with two independent synergies accounting for approximately 80% of the data variability were able to walk with the robot. This observation was not consistently apparent with conventional clinical measures such as the Brunnstrom stages. This paper contributes to the field of robot-assisted locomotion therapy by introducing the concept of inter-limb synergies, demonstrating performance differences between synergy-based and autonomous robot control, and investigating the range of disability in which the system is usable.

  8. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    PubMed Central

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  9. Robot-assisted pancreatic surgery: a systematic review of the literature.

    PubMed

    Strijker, Marin; van Santvoort, Hjalmar C; Besselink, Marc G; van Hillegersberg, Richard; Borel Rinkes, Inne H M; Vriens, Menno R; Molenaar, I Quintus

    2013-01-01

    To potentially improve outcomes in pancreatic resection, robot-assisted pancreatic surgery has been introduced. This technique has possible advantages over laparoscopic surgery, such as its affordance of three-dimensional vision and increased freedom of movement of instruments. A systematic review was performed to assess the safety and feasibility of robot-assisted pancreatic surgery. The literature published up to 30 September 2011 was systematically reviewed, with no restrictions on publication date. Studies reporting on over five patients were included. Animal studies, studies not reporting morbidity and mortality, review articles and conference abstracts were excluded. Data were extracted and weighted means were calculated. A total of 499 studies were screened, after which eight cohort studies reporting on a total of 251 patients undergoing robot-assisted pancreatic surgery were retained for analysis. Weighted mean operation time was 404 ± 102 min (510 ± 107 min for pancreatoduodenectomy only). The rate of conversion was 11.0% (16.4% for pancreatoduodenectomy only). Overall morbidity was 30.7% (n = 77), most frequently involving pancreatic fistulae (n = 46). Mortality was 1.6%. Negative surgical margins were obtained in 92.9% of patients. The rate of spleen preservation in distal pancreatectomy was 87.1%. Robot-assisted pancreatic surgery seems to be safe and feasible in selected patients and, in left-sided resections, may increase the rate of spleen preservation. Randomized studies should compare the respective outcomes of robot-assisted, laparoscopic and open pancreatic surgery. © 2012 International Hepato-Pancreato-Biliary Association.

  10. Robot-assisted pancreatic surgery: a systematic review of the literature

    PubMed Central

    Strijker, Marin; van Santvoort, Hjalmar C; Besselink, Marc G; van Hillegersberg, Richard; Borel Rinkes, Inne HM; Vriens, Menno R; Molenaar, I Quintus

    2013-01-01

    Background To potentially improve outcomes in pancreatic resection, robot-assisted pancreatic surgery has been introduced. This technique has possible advantages over laparoscopic surgery, such as its affordance of three-dimensional vision and increased freedom of movement of instruments. A systematic review was performed to assess the safety and feasibility of robot-assisted pancreatic surgery. Methods The literature published up to 30 September 2011 was systematically reviewed, with no restrictions on publication date. Studies reporting on over five patients were included. Animal studies, studies not reporting morbidity and mortality, review articles and conference abstracts were excluded. Data were extracted and weighted means were calculated. Results A total of 499 studies were screened, after which eight cohort studies reporting on a total of 251 patients undergoing robot-assisted pancreatic surgery were retained for analysis. Weighted mean operation time was 404 ± 102 min (510 ± 107 min for pancreatoduodenectomy only). The rate of conversion was 11.0% (16.4% for pancreatoduodenectomy only). Overall morbidity was 30.7% (n = 77), most frequently involving pancreatic fistulae (n = 46). Mortality was 1.6%. Negative surgical margins were obtained in 92.9% of patients. The rate of spleen preservation in distal pancreatectomy was 87.1%. Conclusions Robot-assisted pancreatic surgery seems to be safe and feasible in selected patients and, in left-sided resections, may increase the rate of spleen preservation. Randomized studies should compare the respective outcomes of robot-assisted, laparoscopic and open pancreatic surgery. PMID:23216773

  11. Kinematic, muscular, and metabolic responses during exoskeletal-, elliptical-, or therapist-assisted stepping in people with incomplete spinal cord injury.

    PubMed

    Hornby, T George; Kinnaird, Catherine R; Holleran, Carey L; Rafferty, Miriam R; Rodriguez, Kelly S; Cain, Julie B

    2012-10-01

    Robotic-assisted locomotor training has demonstrated some efficacy in individuals with neurological injury and is slowly gaining clinical acceptance. Both exoskeletal devices, which control individual joint movements, and elliptical devices, which control endpoint trajectories, have been utilized with specific patient populations and are available commercially. No studies have directly compared training efficacy or patient performance during stepping between devices. The purpose of this study was to evaluate kinematic, electromyographic (EMG), and metabolic responses during elliptical- and exoskeletal-assisted stepping in individuals with incomplete spinal cord injury (SCI) compared with therapist-assisted stepping. Design A prospective, cross-sectional, repeated-measures design was used. Participants with incomplete SCI (n=11) performed 3 separate bouts of exoskeletal-, elliptical-, or therapist-assisted stepping. Unilateral hip and knee sagittal-plane kinematics, lower-limb EMG recordings, and oxygen consumption were compared across stepping conditions and with control participants (n=10) during treadmill stepping. Exoskeletal stepping kinematics closely approximated normal gait patterns, whereas significantly greater hip and knee flexion postures were observed during elliptical-assisted stepping. Measures of kinematic variability indicated consistent patterns in control participants and during exoskeletal-assisted stepping, whereas therapist- and elliptical-assisted stepping kinematics were more variable. Despite specific differences, EMG patterns generally were similar across stepping conditions in the participants with SCI. In contrast, oxygen consumption was consistently greater during therapist-assisted stepping. Limitations Limitations included a small sample size, lack of ability to evaluate kinetics during stepping, unilateral EMG recordings, and sagittal-plane kinematics. Despite specific differences in kinematics and EMG activity, metabolic activity was similar during stepping in each robotic device. Understanding potential differences and similarities in stepping performance with robotic assistance may be important in delivery of repeated locomotor training using robotic or therapist assistance and for consumers of robotic devices.

  12. Ground robotic measurement of aeolian processes

    NASA Astrophysics Data System (ADS)

    Qian, Feifei; Jerolmack, Douglas; Lancaster, Nicholas; Nikolich, George; Reverdy, Paul; Roberts, Sonia; Shipley, Thomas; Van Pelt, R. Scott; Zobeck, Ted M.; Koditschek, Daniel E.

    2017-08-01

    Models of aeolian processes rely on accurate measurements of the rates of sediment transport by wind, and careful evaluation of the environmental controls of these processes. Existing field approaches typically require intensive, event-based experiments involving dense arrays of instruments. These devices are often cumbersome and logistically difficult to set up and maintain, especially near steep or vegetated dune surfaces. Significant advances in instrumentation are needed to provide the datasets that are required to validate and improve mechanistic models of aeolian sediment transport. Recent advances in robotics show great promise for assisting and amplifying scientists' efforts to increase the spatial and temporal resolution of many environmental measurements governing sediment transport. The emergence of cheap, agile, human-scale robotic platforms endowed with increasingly sophisticated sensor and motor suites opens up the prospect of deploying programmable, reactive sensor payloads across complex terrain in the service of aeolian science. This paper surveys the need and assesses the opportunities and challenges for amassing novel, highly resolved spatiotemporal datasets for aeolian research using partially-automated ground mobility. We review the limitations of existing measurement approaches for aeolian processes, and discuss how they may be transformed by ground-based robotic platforms, using examples from our initial field experiments. We then review how the need to traverse challenging aeolian terrains and simultaneously make high-resolution measurements of critical variables requires enhanced robotic capability. Finally, we conclude with a look to the future, in which robotic platforms may operate with increasing autonomy in harsh conditions. Besides expanding the completeness of terrestrial datasets, bringing ground-based robots to the aeolian research community may lead to unexpected discoveries that generate new hypotheses to expand the science itself.

  13. How robotic-assisted surgery can decrease the risk of mucosal tear during Heller myotomy procedure?

    PubMed

    Ballouhey, Quentin; Dib, Nabil; Binet, Aurélien; Carcauzon-Couvrat, Véronique; Clermidi, Pauline; Longis, Bernard; Lardy, Hubert; Languepin, Jane; Cros, Jérôme; Fourcade, Laurent

    2017-06-01

    We report the first description of robotic-assisted Heller myotomy in children. The purpose of this study was to improve the safety of Heller myotomy by demonstrating, in two adolescent patients, the contribution of the robot to the different steps of this procedure. Due to the robot's freedom of movement and three-dimensional vision, there was an improvement in the accuracy, a gain in the safety regarding different key-points, decreasing the risk of mucosal perforation associated with this procedure.

  14. Robot-assisted thoracoscopic surgery with simple laparoscopy for diaphragm eventration.

    PubMed

    Ahn, Joong Hyun; Suh, Jong Hui; Jeong, Jin Yong

    2013-09-01

    Robot-assisted thoracoscopic surgery has been applied for general thoracic operations. Its advantages include not only those of minimally invasive surgery but also those of magnified three-dimensional vision and angulation of the robotic arm. However, there are no direct tactile sensation and force feedback, which can cause unwanted organ damage. We therefore used laparoscopy simultaneously to avoid a blind intraperitoneal area during robotic surgery for diaphragmatic eventration via transthoracic approach and describe the technique herein. Georg Thieme Verlag KG Stuttgart · New York.

  15. Robotic Technology Efforts at the NASA/Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Diftler, Ron

    2017-01-01

    The NASA/Johnson Space Center has been developing robotic systems in support of space exploration for more than two decades. The goal of the Center’s Robotic Systems Technology Branch is to design and build hardware and software to assist astronauts in performing their mission. These systems include: rovers, humanoid robots, inspection devices and wearable robotics. Inspection systems provide external views of space vehicles to search for surface damage and also maneuver inside restricted areas to verify proper connections. New concepts in human and robotic rovers offer solutions for navigating difficult terrain expected in future planetary missions. An important objective for humanoid robots is to relieve the crew of “dull, dirty or dangerous” tasks allowing them more time to perform their important science and exploration missions. Wearable robotics one of the Center’s newest development areas can provide crew with low mass exercise capability and also augment an astronaut’s strength while wearing a space suit.This presentation will describe the robotic technology and prototypes developed at the Johnson Space Center that are the basis for future flight systems. An overview of inspection robots will show their operation on the ground and in-orbit. Rovers with independent wheel modules, crab steering, and active suspension are able to climb over large obstacles, and nimbly maneuver around others. Humanoid robots, including the First Humanoid Robot in Space: Robonaut 2, demonstrate capabilities that will lead to robotic caretakers for human habitats in space, and on Mars. The Center’s Wearable Robotics Lab supports work in assistive and sensing devices, including exoskeletons, force measuring shoes, and grasp assist gloves.

  16. Robotic Technology Efforts at the NASA/Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Diftler, Ron

    2017-01-01

    The NASA/Johnson Space Center has been developing robotic systems in support of space exploration for more than two decades. The goal of the Center's Robotic Systems Technology Branch is to design and build hardware and software to assist astronauts in performing their mission. These systems include: rovers, humanoid robots, inspection devices and wearable robotics. Inspection systems provide external views of space vehicles to search for surface damage and also maneuver inside restricted areas to verify proper connections. New concepts in human and robotic rovers offer solutions for navigating difficult terrain expected in future planetary missions. An important objective for humanoid robots is to relieve the crew of "dull, dirty or dangerous" tasks allowing them more time to perform their important science and exploration missions. Wearable robotics one of the Center's newest development areas can provide crew with low mass exercise capability and also augment an astronaut's strength while wearing a space suit. This presentation will describe the robotic technology and prototypes developed at the Johnson Space Center that are the basis for future flight systems. An overview of inspection robots will show their operation on the ground and in-orbit. Rovers with independent wheel modules, crab steering, and active suspension are able to climb over large obstacles, and nimbly maneuver around others. Humanoid robots, including the First Humanoid Robot in Space: Robonaut 2, demonstrate capabilities that will lead to robotic caretakers for human habitats in space, and on Mars. The Center's Wearable Robotics Lab supports work in assistive and sensing devices, including exoskeletons, force measuring shoes, and grasp assist gloves.

  17. Robotic assisted gait as a tool for rehabilitation of individuals with spinal cord injury: a systematic review.

    PubMed

    Holanda, Ledycnarf J; Silva, Patrícia M M; Amorim, Thiago C; Lacerda, Matheus O; Simão, Camila R; Morya, Edgard

    2017-12-04

    Spinal cord injury (SCI) is characterized by a total or partial deficit of sensory and motor pathways. Impairments of this injury compromise muscle recruitment and motor planning, thus reducing functional capacity. SCI patients commonly present psychological, intestinal, urinary, osteomioarticular, tegumentary, cardiorespiratory and neural alterations that aggravate in chronic phase. One of the neurorehabilitation goals is the restoration of these abilities by favoring improvement in the quality of life and functional independence. Current literature highlights several benefits of robotic gait therapies in SCI individuals. The purpose of this study was to compare the robotic gait devices, and systematize the scientific evidences of these devices as a tool for rehabilitation of SCI individuals. A systematic review was carried out in which relevant articles were identified by searching the following databases: Cochrane Library, PubMed, PEDro and Capes Periodic. Two authors selected the articles which used a robotic device for rehabilitation of spinal cord injury. Databases search found 2941 articles, 39 articles were included due to meet the inclusion criteria. The robotic devices presented distinct features, with increasing application in the last years. Studies have shown promising results regarding the reduction of pain perception and spasticity level; alteration of the proprioceptive capacity, sensitivity to temperature, vibration, pressure, reflex behavior, electrical activity at muscular and cortical level, classification of the injury level; increase in walking speed, step length and distance traveled; improvements in sitting posture, intestinal, cardiorespiratory, metabolic, tegmental and psychological functions. This systematic review shows a significant progress encompassing robotic devices as an innovative and effective therapy for the rehabilitation of individuals with SCI.

  18. Extrafascial versus interfascial nerve-sparing technique for robotic-assisted laparoscopic prostatectomy: comparison of functional outcomes and positive surgical margins characteristics.

    PubMed

    Shikanov, Sergey; Woo, Jason; Al-Ahmadie, Hikmat; Katz, Mark H; Zagaja, Gregory P; Shalhav, Arieh L; Zorn, Kevin C

    2009-09-01

    To evaluate the pathologic and functional outcomes of patients with bilateral interfascial (IF) or extrafascial nerve-sparing (EF-NSP) techniques. It is believed that the IF-NSP technique used during robotic-assisted radical prostatectomy (RARP) spares more nerve fibers, while EF dissection may lower the risk for positive surgical margins (PSM). A prospective database was analyzed for RARP patients with bilateral IF- or EF-NSP technique. Collected parameters included age, body mass index, prostate-specific antigen, clinical and pathologic Gleason score and stage, estimated blood loss, operative time, and PSM characteristics. Functional outcomes were evaluated with the use of the University of California Los Angeles Prostate Cancer Index questionnaire. Men receiving postoperative hormonal or radiation therapy were excluded from sexual function analysis. A total of 110 and 703 cases with bilateral EF- and IF-NSP, respectively, were analyzed. EF-NSP patients had higher prostate-specific antigen, clinical, pathologic stage, and pathologic Gleason score. PSM rate did not achieve statistically significant difference between groups. There was a trend toward lower pT3-PSM in the EF group (51% vs 28%; P = .08). Mid- and posterolateral PSM location were lower in the EF-NSP group, 11% vs 37% and 11% vs 29%, respectively (P < .001). The IF-NSP group patients achieved statistically significant better sexual function (P = .02) and potency rates (P = .03) at 12 months after RARP. In lower risk patients, bilateral IF-NSP technique does not result in significantly higher PSM rates. EF-NSP appears to reduce posterolateral and mid-prostate PSM. Men with bilateral IF-NSP demonstrate significantly better sexual function outcomes.

  19. Transcontinental telementoring with pediatric surgeons: proof of concept and technical considerations.

    PubMed

    Ponsky, Todd A; Bobanga, Iuliana D; Schwachter, Marc; Stathos, Theodore H; Rosen, Michael; Parry, Robert; Nalugo, Margaret; Rothenberg, Steven S

    2014-12-01

    To evaluate different technologies that can facilitate telementoring in a variety of pediatric surgical procedures. Two different telementoring technologies were used to provide two-way audio and visual communication between experienced pediatric surgeon mentors located in another city and less experienced trainees performing a surgical procedure. The first technology consisted of store-bought equipment that connected the operating room laparoscope to a Skype™ (Microsoft, Redmond, WA) connection (used in 1 case), whereas the second was a proprietary telementoring robot, Karl Storz Endoscopy-America, Inc. VisitOR1(®) (Karl Storz GmbH & Co. KG, Tuttlingen, Germany) (used in 5 cases). The procedures included a video-assisted thoracic surgery lower lobectomy, a temporary and two permanent gastric stimulator placements, and two laparoscopic inguinal hernia repairs and were performed by pediatric surgeons (3 cases), a pediatric gastroenterologist (1 case), and a general surgeon (2 cases) under the guidance of pediatric surgeon mentors. All procedures were completed successfully in a time-efficient manner, without loss of transmission and without complications. Although the Skype technology was less costly, it lacked telestrator capacity and was not adequately secure. The VisitOR1 telementoring robot enabled high-resolution video communication, had telestrator capacity, and allowed pointing during the procedure. The mentors assisted with trocar placement, modifying the surgical technique, identifying planes of dissection, and indicating locations of device and suture placement. Telementoring is a useful adjunct in the field of pediatric surgery that can aid in the transfer of surgical skills remotely and shorten the time to implementation of new surgical techniques into practice. Optimal telementoring technology should have a secure wireless connection, high video resolution, and minimal bandwidth latency.

  20. Development of a Patient-Based Model for Estimating Operative Times for Robot-Assisted Radical Prostatectomy.

    PubMed

    Huben, Neil; Hussein, Ahmed; May, Paul; Whittum, Michelle; Kraswowki, Collin; Ahmed, Youssef; Jing, Zhe; Khan, Hijab; Kim, Hyung; Schwaab, Thomas; Underwood Iii, Willie; Kauffman, Eric; Mohler, James L; Guru, Khurshid A

    2018-04-10

    To develop a methodology for predicting operative times for robot-assisted radical prostatectomy (RARP) using preoperative patient, disease, procedural and surgeon variables to facilitate operating room (OR) scheduling. The model included preoperative metrics: BMI, ASA score, clinical stage, National Comprehensive Cancer Network (NCCN) risk, prostate weight, nerve-sparing status, extent and laterality of lymph node dissection, and operating surgeon (6 surgeons were included in the study). A binary decision tree was fit using a conditional inference tree method to predict operative times. The variables most associated with operative time were determined using permutation tests. The data was split at the value of the variable that results in the largest difference in means for surgical time across the split. This process was repeated recursively on the resultant data. 1709 RARPs were included. The variable most strongly associated with operative time was the surgeon (surgeons 2 and 4 - 102 minutes shorter than surgeons 1, 3, 5, and 6, p<0.001). Among surgeons 2 and 4, BMI had the strongest association with surgical time (p<0.001). Among patients operated by surgeons 1, 3, 5 and 6, RARP time was again most strongly associated with the surgeon performing RARP. Surgeons 1, 3, and 6 were on average 76 minutes faster than surgeon 5 (p<0.001). The regression tree output in the form of box plots showed operative time median and ranges according to patient, disease, procedural and surgeon metrics. We developed a methodology that can predict operative times for RARP based on patient, disease and surgeon variables. This methodology can be utilized for quality control, facilitate OR scheduling and maximize OR efficiency.

Top