Sample records for distance vision glasses

  1. Distance vision after bilateral implantation of AcrySof toric intraocular lenses: a randomized, controlled, prospective trial

    PubMed Central

    Zhang, Jin-Song; Zhao, Jiang-Yue; Sun, Qi; Ma, Li-Wei

    2011-01-01

    AIM To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL. METHODS This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL. IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients. Assessments included monocular and binocular distance vision, with and without best correction. Patients also completed surveys about their distance vision. RESULTS Preoperatively, the two study groups were similar in age, in distance visual acuity, and in the magnitude of corneal astigmatism. At 6 months postoperative, binocular uncorrected distance vision was 0.06±0.14 logMAR in the AcrySof toric IOL group, significantly better than the 0.14±0.11 logMAR in the spherical IOL group (P<0.05). For eyes with emmetropia as a target, the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes). No patients in the emmetropia/toric IOL group used distance glasses, as compared to 52% of patients in the emmetropia/spherical IOL group. All patients were satisfied or highly satisfied. Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05). CONCLUSION Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism. PMID:22553636

  2. Stereo vision with distance and gradient recognition

    NASA Astrophysics Data System (ADS)

    Kim, Soo-Hyun; Kang, Suk-Bum; Yang, Tae-Kyu

    2007-12-01

    Robot vision technology is needed for the stable walking, object recognition and the movement to the target spot. By some sensors which use infrared rays and ultrasonic, robot can overcome the urgent state or dangerous time. But stereo vision of three dimensional space would make robot have powerful artificial intelligence. In this paper we consider about the stereo vision for stable and correct movement of a biped robot. When a robot confront with an inclination plane or steps, particular algorithms are needed to go on without failure. This study developed the recognition algorithm of distance and gradient of environment by stereo matching process.

  3. Glass Vision 3D: Digital Discovery for the Deaf

    ERIC Educational Resources Information Center

    Parton, Becky Sue

    2017-01-01

    Glass Vision 3D was a grant-funded project focused on developing and researching a Google Glass app that would allowed young Deaf children to look at the QR code of an object in the classroom and see an augmented reality projection that displays an American Sign Language (ASL) related video. Twenty five objects and videos were prepared and tested…

  4. Polarization vision seldom increases the sighting distance of silvery fish.

    PubMed

    Johnsen, Sönke; Gagnon, Yakir L; Marshall, N Justin; Cronin, Thomas W; Gruev, Viktor; Powell, Samuel

    2016-08-22

    Although the function of polarization vision, the ability to discern the polarization characteristics of light, is well established in many terrestrial and benthic species, its purpose in pelagic species (squid and certain fish and crustaceans) is poorly understood [1]. A long-held hypothesis is that polarization vision in open water is used to break the mirror camouflage of silvery fish, as biological mirrors can change the polarization of reflected light [2,3]. Although, the addition of polarization information may increase the conspicuousness of silvery fish at close range, direct evidence that silvery fish - or indeed any pelagic animal - are visible at longer distances using polarization vision rather than using radiance (i.e. brightness) vision is lacking. Here we show, using in situ polarization imagery and a new visual detection model, that polarization vision does not in fact appear to allow viewers to see silvery fish at greater distances. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Carrying Out and Developing the Glass Industry Vision and Roadmap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael Greenman

    2007-06-14

    In support of its obligations under the above-mentioned project, the GMIC performed the following tasks: (1) Provided two-way communications liaison services between the U.S. glass industry and the D.O.E. to ensure the needs and concerns of each party are effectively communicated to the other. (2) Updated and modified on a continuing basis and in response to evolving conditions within the glass industry, the goals and priorities outlined in the Glass Industry Vision and the Glass Technology Roadmap. (3) Established relationships with a wide variety of government and non-governmental organizations with interests in further improving the levels of technology, productivity andmore » environmental responsibility of the glass industry. (4) Canvassed the glass industry on an ongoing basis to determine overall and specific sector needs for technological development. (5) Fostered direct contacts between member companies and national laboratories to facilitate the development of individual company technology development. (6) Advised the DOE on the key elements of the solicitation process in support of the Glass Industry Vision and Technology Roadmap. In the course of this contract, the membership of the GMIC has grown to include over 70% of the glass industry. This gives it the ability to communicate persuasively with the vast majority of this energy intensive industry. One of the principal benefits of the existence of the GMIC is that, for the first time in this country, representative companies of all major sectors of the glass industry are now in regular communication with each other. Prior to the existence and activity of the GMIC, companies and individuals in the flat glass, container glass, fiber glass and specialty glass sectors rarely had contact with each other, in spite of the fact that they all face similar challenges and can benefit from pre-competitive research conducted to the benefit of the broad industry. The development of innovations in the industry

  6. The effect of Medicaid adult vision coverage on the likelihood of appropriate correction of distance vision: Evidence from the National Health and Nutrition Examination Survey.

    PubMed

    Lipton, Brandy J; Decker, Sandra L

    2016-02-01

    Medicaid is the main public health insurance program for individuals with low income in the United States. Some state Medicaid programs cover preventive eye care services and vision correction, while others cover emergency eye care only. Similar to other optional benefits, states may add and drop adult vision benefits over time. This article examines whether providing adult vision benefits is associated with an increase in the percentage of low-income individuals with appropriately corrected distance vision as measured during an eye exam. We estimate the effect of Medicaid vision coverage on the likelihood of having appropriately corrected distance vision using examination data from the 2001-2008 National Health and Nutrition Examination Survey. We compare vision outcomes for Medicaid beneficiaries (n = 712) and other low income adults not enrolled in Medicaid (n = 4786) before and after changes to state vision coverage policies. Between 29 and 33 states provided Medicaid adult vision benefits during 2001-2008, depending on the year. Our findings imply that Medicaid adult vision coverage is associated with a significant increase in the percentage of Medicaid beneficiaries with appropriately corrected distance vision of up to 10 percentage points. Providing vision coverage to adults on Medicaid significantly increases the likelihood of appropriate correction of distance vision. Further research on the impact of vision coverage on related functional outcomes and the effects of Medicaid coverage of other services may be appropriate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. The role of vision in auditory distance perception.

    PubMed

    Calcagno, Esteban R; Abregú, Ezequiel L; Eguía, Manuel C; Vergara, Ramiro

    2012-01-01

    In humans, multisensory interaction is an important strategy for improving the detection of stimuli of different nature and reducing the variability of response. It is known that the presence of visual information affects the auditory perception in the horizontal plane (azimuth), but there are few researches that study the influence of vision in the auditory distance perception. In general, the data obtained from these studies are contradictory and do not completely define the way in which visual cues affect the apparent distance of a sound source. Here psychophysical experiments on auditory distance perception in humans are performed, including and excluding visual cues. The results show that the apparent distance from the source is affected by the presence of visual information and that subjects can store in their memory a representation of the environment that later improves the perception of distance.

  8. Machine vision based quality inspection of flat glass products

    NASA Astrophysics Data System (ADS)

    Zauner, G.; Schagerl, M.

    2014-03-01

    This application paper presents a machine vision solution for the quality inspection of flat glass products. A contact image sensor (CIS) is used to generate digital images of the glass surfaces. The presented machine vision based quality inspection at the end of the production line aims to classify five different glass defect types. The defect images are usually characterized by very little `image structure', i.e. homogeneous regions without distinct image texture. Additionally, these defect images usually consist of only a few pixels. At the same time the appearance of certain defect classes can be very diverse (e.g. water drops). We used simple state-of-the-art image features like histogram-based features (std. deviation, curtosis, skewness), geometric features (form factor/elongation, eccentricity, Hu-moments) and texture features (grey level run length matrix, co-occurrence matrix) to extract defect information. The main contribution of this work now lies in the systematic evaluation of various machine learning algorithms to identify appropriate classification approaches for this specific class of images. In this way, the following machine learning algorithms were compared: decision tree (J48), random forest, JRip rules, naive Bayes, Support Vector Machine (multi class), neural network (multilayer perceptron) and k-Nearest Neighbour. We used a representative image database of 2300 defect images and applied cross validation for evaluation purposes.

  9. The Effects of Practice with Prescribed Reading Glasses on Students with Low Vision.

    ERIC Educational Resources Information Center

    Smith, Janice K.; Erin, Jane N.

    2002-01-01

    A study investigated effects of regular instruction and practice with prescription reading glasses with three adolescents with low vision. Two students demonstrated no advantage in reading large print and one student experienced a decreased reading rate using standard print and reading glasses. Students preferred reading standard print with…

  10. Distance Learning and Assistance Using Smart Glasses

    ERIC Educational Resources Information Center

    Spitzer, Michael; Nanic, Ibrahim; Ebner, Martin

    2018-01-01

    With the everyday growth of technology, new possibilities arise to support activities of everyday life. In education and training, more and more digital learning materials are emerging, but there is still room for improvement. This research study describes the implementation of a smart glasses app and infrastructure to support distance learning…

  11. Effects of Background Lighting Color and Movement Distance on Reaching Times Among Participants With Low Vision, Myopia, and Normal Vision.

    PubMed

    Chen, Chun-Fu; Huang, Kuo-Chen

    2016-04-01

    This study investigated the effects of target distance (30, 35, and 40 cm) and the color of background lighting (red, green, blue, and yellow) on the duration of movements made by participants with low vision, myopia, and normal vision while performing a reaching task; 48 students (21 women, 27 men; M age = 21.8 year, SD = 2.4) participated in the study. Participants reached for a target (a white LED light) whose vertical position varied randomly across trials, ranging in distance from 30 to 40 cm. Movement time was analyzed using a 3 (participant group) × [4 (color of background lighting) × 3 (movement distance)] mixed-design ANOVA model. Results indicated longer times for completing a reaching movement when: participants belonged to the low vision group; the target distance between the starting position and the target position was longer (40 cm); and the reaching movement occurred in the red-background lighting condition. These results are particularly relevant for situations in which a user is required to respond to a signal by reaching toward a button or an icon. © The Author(s) 2016.

  12. Rapid Vision Correction by Special Operations Forces.

    PubMed

    Reynolds, Mark E

    This report describes a rapid method of vision correction used by Special Operations Medics in multiple operational engagements. Between 2011 and 2015, Special Operations Medics used an algorithm- driven refraction technique. A standard block of instruction was provided to the medics, along with a packaged kit. The technique was used in multiple operational engagements with host nation military and civilians. Data collected for program evaluation were later analyzed to assess the utility of the technique. Glasses were distributed to 230 patients with complaints of either decreased distance or near (reading). Most patients (84%) with distance complaints achieved corrected binocular vision of 20/40 or better, and 97% of patients with near-vision complaints achieved corrected near-binocular vision of 20/40 or better. There was no statistically significant difference between the percentages of patients achieving 20/40 when medics used the technique under direct supervision versus independent use. A basic refraction technique using a designed kit allows for meaningful improvement in distance and/or near vision at austere locations. Special Operations Medics can leverage this approach after specific training with minimal time commitment. It can serve as a rapid, effective intervention with multiple applications in diverse operational environments. 2017.

  13. [Clinical observation on the relation between laser in situ keratomileusis treating myopic anisometropia and binocular vision].

    PubMed

    Huang, Jing; Lu, Wei

    2009-09-29

    To analyze the effect of LASIK on visual quality of anisometropia, and evaluate its clinical value in the view of visual quality. Prospective observational case series. Assayed the naked vision, glasses-corrected vision and binocular vision of 45 cases with anisometropia >or= 2.25D before and after the operation of LASIK. 91.57% of the eyes after the operation reached the vision >or= 0.8, which says a significant improvement for binocular vision after the operation (P < 0.05). There was a significant difference on diopter between the pre-operation and post-operation (P < 0.05). As for anisometropia, there was no significant difference between simultaneous binocular visions (P = 0.431), but there was of great significance among combined, short and long distance stereopsis visions (P = 0.000). Binocular vision deteriorated as anisometropia increased (P < 0.05). The short distance stereopsis visions of LASIK-treated myopic anisometropia were better than that of glasses-corrected patients (P < 0.05). The operation of LASIK can improve the visual quality and resume the binocular vision. LASIK can correct anisometropia and its therapeutic efficacy deserves to confirm.

  14. Role of the Short Distance Order in Glass Reactivity

    PubMed Central

    2018-01-01

    In 2005, our group described for the first time the structural characterization at the atomic scale of bioactive glasses and the influence of the glasses’ nanostructure in their reactivity in simulated body fluids. In that study, two bioactive sol-gel glasses with composition 80%SiO2–20%CaO and 80%SiO2–17%CaO–3%P2O5 (in mol-%) were characterized by High-Resolution Transmission Electron Microscopy (HRTEM). Such characterization revealed unknown features of the glasses’ structure at the local scale that allowed the understanding of their different in vitro behaviors as a consequence of the presence or absence of P2O5. Since then, the nanostructure of numerous bioactive glasses, including melt-prepared, sol-gel derived, and mesoporous glasses, was investigated by HRTEM, Nuclear Magnetic Resonance (NMR) spectroscopy, Molecular Dynamics (MD) simulations, and other experimental techniques. These studies have shown that although glasses are amorphous solids, a certain type of short distance order, which greatly influences the in vitro and in vivo reactivity, is always present. This paper reviews the most significant advances in the understanding of bioactive glasses that took place in the last years as a result of the growing knowledge of the glasses’ nanostructure. PMID:29534481

  15. Improving Vision

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Many people are familiar with the popular science fiction series Star Trek: The Next Generation, a show featuring a blind character named Geordi La Forge, whose visor-like glasses enable him to see. What many people do not know is that a product very similar to Geordi's glasses is available to assist people with vision conditions, and a NASA engineer's expertise contributed to its development. The JORDY(trademark) (Joint Optical Reflective Display) device, designed and manufactured by a privately-held medical device company known as Enhanced Vision, enables people with low vision to read, write, and watch television. Low vision, which includes macular degeneration, diabetic retinopathy, and glaucoma, describes eyesight that is 20/70 or worse, and cannot be fully corrected with conventional glasses.

  16. Characteristics of the Arcing Plasma Formation Effect in Spark-Assisted Chemical Engraving of Glass, Based on Machine Vision

    PubMed Central

    Wu, Dung-Sheng

    2018-01-01

    Spark-assisted chemical engraving (SACE) is a non-traditional machining technology that is used to machine electrically non-conducting materials including glass, ceramics, and quartz. The processing accuracy, machining efficiency, and reproducibility are the key factors in the SACE process. In the present study, a machine vision method is applied to monitor and estimate the status of a SACE-drilled hole in quartz glass. During the machining of quartz glass, the spring-fed tool electrode was pre-pressured on the quartz glass surface to feed the electrode that was in contact with the machining surface of the quartz glass. In situ image acquisition and analysis of the SACE drilling processes were used to analyze the captured image of the state of the spark discharge at the tip and sidewall of the electrode. The results indicated an association between the accumulative size of the SACE-induced spark area and deepness of the hole. The results indicated that the evaluated depths of the SACE-machined holes were a proportional function of the accumulative spark size with a high degree of correlation. The study proposes an innovative computer vision-based method to estimate the deepness and status of SACE-drilled holes in real time. PMID:29565303

  17. Characteristics of the Arcing Plasma Formation Effect in Spark-Assisted Chemical Engraving of Glass, Based on Machine Vision.

    PubMed

    Ho, Chao-Ching; Wu, Dung-Sheng

    2018-03-22

    Spark-assisted chemical engraving (SACE) is a non-traditional machining technology that is used to machine electrically non-conducting materials including glass, ceramics, and quartz. The processing accuracy, machining efficiency, and reproducibility are the key factors in the SACE process. In the present study, a machine vision method is applied to monitor and estimate the status of a SACE-drilled hole in quartz glass. During the machining of quartz glass, the spring-fed tool electrode was pre-pressured on the quartz glass surface to feed the electrode that was in contact with the machining surface of the quartz glass. In situ image acquisition and analysis of the SACE drilling processes were used to analyze the captured image of the state of the spark discharge at the tip and sidewall of the electrode. The results indicated an association between the accumulative size of the SACE-induced spark area and deepness of the hole. The results indicated that the evaluated depths of the SACE-machined holes were a proportional function of the accumulative spark size with a high degree of correlation. The study proposes an innovative computer vision-based method to estimate the deepness and status of SACE-drilled holes in real time.

  18. Magnifying Smartphone Screen Using Google Glass for Low-Vision Users.

    PubMed

    Pundlik, Shrinivas; HuaQi Yi; Rui Liu; Peli, Eli; Gang Luo

    2017-01-01

    Magnification is a key accessibility feature used by low-vision smartphone users. However, small screen size can lead to loss of context and make interaction with magnified displays challenging. We hypothesize that controlling the viewport with head motion can be natural and help in gaining access to magnified displays. We implement this idea using a Google Glass that displays the magnified smartphone screenshots received in real time via Bluetooth. Instead of navigating with touch gestures on the magnified smartphone display, the users can view different screen locations by rotating their head, and remotely interacting with the smartphone. It is equivalent to looking at a large virtual image through a head contingent viewing port, in this case, the Glass display with ~ 15 ° field of view. The system can transfer seven screenshots per second at 8 × magnification, sufficient for tasks where the display content does not change rapidly. A pilot evaluation of this approach was conducted with eight normally sighted and four visually impaired subjects performing assigned tasks using calculator and music player apps. Results showed that performance in the calculation task was faster with the Glass than with the phone's built-in screen zoom. We conclude that head contingent scanning control can be beneficial in navigating magnified small smartphone displays, at least for tasks involving familiar content layout.

  19. Pinhole Glasses

    NASA Astrophysics Data System (ADS)

    Colicchia, Giuseppe; Hopf, Martin; Wiesner, Hartmut; Zollman, Dean

    2008-01-01

    Eye aberrations are commonly corrected by lenses that restore vision by altering rays before they pass through the cornea. Some modern promoters claim that pinhole glasses are better than conventional lenses in correcting all kinds of refractive defects such as myopia (nearsighted), hyperopia (farsighted), astigmatisms, and presbyopia. Do pinhole glasses really give better vision? Some ways to use this question for motivation in teaching optics have been discussed. For this column we include a series of experiments that students can complete using a model of the eye and demonstrate issues related to pinhole vision correction.

  20. Single bubble perturbation in cavitation proximity of solid glass: hot spot versus distance.

    PubMed

    Radziuk, Darya; Möhwald, Helmuth; Suslick, Kenneth

    2014-02-28

    A systematic study of the energy loss of a cavitation bubble in a close proximity of a glass surface is introduced for the first time in a low acoustic field (1.2-2.4 bar). Single bubble sonoluminescence (SBSL) is used as a tool to predict the temperature and pressure decrease of bubble (μm) versus surface distance. A glass as a model system is used to imitate the boundary conditions relevant for nano- or micromaterials. SBSL preequilibrated with 5% argon is perturbed by a glass rod with the tip (Z-perturbation) and with the long axis (X-perturbation) at a defined distance. From 2 mm to 500 μm argon-SBSL lines monotonically narrow and the effective emission temperature decreases from 9000 K to 6800 K comparable to multiple bubbles. The electron density decreases by two orders of magnitude in Z-perturbation and is by a factor of two higher in X-perturbation than the unperturbed cavitating bubble. The perturbed single bubble sonoluminescence pressure decreases from 2700 atm to 1200 atm at 2.4 bar. In water new non-SBSL SiO molecular emission lines are observed and OH emission disappears.

  1. Vision Problems in Homeless Children.

    PubMed

    Smith, Natalie L; Smith, Thomas J; DeSantis, Diana; Suhocki, Marissa; Fenske, Danielle

    2015-08-01

    Vision problems in homeless children can decrease educational achievement and quality of life. To estimate the prevalence and specific diagnoses of vision problems in children in an urban homeless shelter. A prospective series of 107 homeless children and teenagers who underwent screening with a vision questionnaire, eye chart screening (if mature enough) and if vision problem suspected, evaluation by a pediatric ophthalmologist. Glasses and other therapeutic interventions were provided if necessary. The prevalence of vision problems in this population was 25%. Common diagnoses included astigmatism, amblyopia, anisometropia, myopia, and hyperopia. Glasses were required and provided for 24 children (22%). Vision problems in homeless children are common and frequently correctable with ophthalmic intervention. Evaluation by pediatric ophthalmologist is crucial for accurate diagnoses and treatment. Our system of screening and evaluation is feasible, efficacious, and reproducible in other homeless care situations.

  2. Preventing falls in older multifocal glasses wearers by providing single-lens distance glasses: the protocol for the VISIBLE randomised controlled trial

    PubMed Central

    Haran, Mark J; Lord, Stephen R; Cameron, Ian D; Ivers, Rebecca Q; Simpson, Judy M; Lee, Bonsan B; Porwal, Mamta; Kwan, Marcella MS; Severino, Connie

    2009-01-01

    Background Recent research has shown that wearing multifocal glasses increases the risk of trips and falls in older people. The aim of this study is to determine whether the provision of single-lens distance glasses to older multifocal glasses wearers, with recommendations for wearing them for walking and outdoor activities, can prevent falls. We will also measure the effect of the intervention on health status, lifestyle activities and fear of falling, as well as the extent of adherence to the program. Methods/Design Approximately 580 older people who are regular wearers of multifocal glasses people will be recruited. Participants will be randomly allocated to either an intervention group (provision of single lens glasses, with counselling and advice about appropriate use) or a control group (usual care). The primary outcome measure will be falls (measured with 13 monthly calendars). Secondary measures will be quality of life, falls efficacy, physical activity levels and adverse events. Discussions The study will determine the impact of providing single-lens glasses, with advice about appropriate use, on preventing falls in older regular wearers of multifocal glasses. This pragmatic intervention, if found to be effective, will guide practitioners with regard to recommending appropriate glasses for minimising the risk of falls in older people. Trial Registration The protocol for this study was registered with the Clinical Trials.gov Protocol Registration System on June 7th 2006 (#350855). PMID:19321012

  3. Vision-Based Detection and Distance Estimation of Micro Unmanned Aerial Vehicles

    PubMed Central

    Gökçe, Fatih; Üçoluk, Göktürk; Şahin, Erol; Kalkan, Sinan

    2015-01-01

    Detection and distance estimation of micro unmanned aerial vehicles (mUAVs) is crucial for (i) the detection of intruder mUAVs in protected environments; (ii) sense and avoid purposes on mUAVs or on other aerial vehicles and (iii) multi-mUAV control scenarios, such as environmental monitoring, surveillance and exploration. In this article, we evaluate vision algorithms as alternatives for detection and distance estimation of mUAVs, since other sensing modalities entail certain limitations on the environment or on the distance. For this purpose, we test Haar-like features, histogram of gradients (HOG) and local binary patterns (LBP) using cascades of boosted classifiers. Cascaded boosted classifiers allow fast processing by performing detection tests at multiple stages, where only candidates passing earlier simple stages are processed at the preceding more complex stages. We also integrate a distance estimation method with our system utilizing geometric cues with support vector regressors. We evaluated each method on indoor and outdoor videos that are collected in a systematic way and also on videos having motion blur. Our experiments show that, using boosted cascaded classifiers with LBP, near real-time detection and distance estimation of mUAVs are possible in about 60 ms indoors (1032×778 resolution) and 150 ms outdoors (1280×720 resolution) per frame, with a detection rate of 0.96 F-score. However, the cascaded classifiers using Haar-like features lead to better distance estimation since they can position the bounding boxes on mUAVs more accurately. On the other hand, our time analysis yields that the cascaded classifiers using HOG train and run faster than the other algorithms. PMID:26393599

  4. What Is Low Vision?

    MedlinePlus

    ... magnifying reading glasses or loupes for seeing the computer screen , sheet music, or for sewing telescopic glasses ... for the Blind services. The Low Vision Pilot Project The American Foundation for the Blind (AFB) has ...

  5. Increasing the object recognition distance of compact open air on board vision system

    NASA Astrophysics Data System (ADS)

    Kirillov, Sergey; Kostkin, Ivan; Strotov, Valery; Dmitriev, Vladimir; Berdnikov, Vadim; Akopov, Eduard; Elyutin, Aleksey

    2016-10-01

    The aim of this work was developing an algorithm eliminating the atmospheric distortion and improves image quality. The proposed algorithm is entirely software without using additional hardware photographic equipment. . This algorithm does not required preliminary calibration. It can work equally effectively with the images obtained at a distances from 1 to 500 meters. An algorithm for the open air images improve designed for Raspberry Pi model B on-board vision systems is proposed. The results of experimental examination are given.

  6. Characteristic of low vision patients attending an eye hospital in eastern region of Nepal.

    PubMed

    Labh, R K; Adhikari, P R; Karki, P; Singh, S K; Sitoula, R P

    2015-01-01

    Low vision is an important public health problem. To study the profile of low vision patients in a hospital of Nepal. Information related to the patients' profile, visual status, ocular disease and, low vision devices prescribed were obtained retrospectively from the records of 1,860 visually- impaired patients, regardless of the cause, presenting to the low vision department of the Biratnagar Eye Hospital, Biratnagar, Nepal, over a period of four years. These patients, after a comprehensive ocular examination, underwent low vision examination by an ophthalmologist and a low vision specialist. Of 1,860 patients, males comprised 1298 (70 %), while 562 (30 %) patients were female. Six hundred and one (32.3%) patients were of less than 20 years while 398(21.4%) were more than 60 years of age. Agriculture (500, 27 %), household work (341, 18 %) and students (308, 17 %) were the common occupations. Retinal diseases were the commonest cause of low vision. They were: macular disorders 408 (22 %), retinitis pigmentosa 226 (12.1 %) and other retinal causes 361 (19.4 %) (diabetic retinopathy, choroidal coloboma, post laser for retinal vasculitis and central retinal/branch retinal vein occlusion, healed macular chorioretinal scar secondary to retinochroiditis and choroiditis). Refractive error 215 (11.5 %), amblyopia 49 (2.6 %), optic atrophy 144 (7.8 %) and microphthalmos 105 (5.6 %) were the other causes. Uncorrected distance visual acuity was between 6/24 and 6/60 in 509 (27.4 %) and between 5/60 and PL in 1,327 (71.3 %) patients. Similarly, near visual acuity with vision better than 2.50 M (N 20) and worse than 2.50 M (N20) was present in 643(34.5%) and 1,217(65.5%) patients. About 67% and 54.5% of the patients had some improvement in their distance and near visual acuity with glasses and low vision aids. Distance spectacles 909 (49 %), near spectacles 106 (5.7 %), hand held magnifiers 78 (4 %) and telescopes 18 (1 %) were the optical devices prescribed. The prevalence of

  7. Glasses for Children

    MedlinePlus

    ... may play an important role in ensuring normal development of vision. The main reasons a child may need glasses are: • To provide better vision, so that a child may function better in his/her environment • To help straighten the eyes when they are ...

  8. An augmented-reality edge enhancement application for Google Glass.

    PubMed

    Hwang, Alex D; Peli, Eli

    2014-08-01

    Google Glass provides a platform that can be easily extended to include a vision enhancement tool. We have implemented an augmented vision system on Glass, which overlays enhanced edge information over the wearer's real-world view, to provide contrast-improved central vision to the Glass wearers. The enhanced central vision can be naturally integrated with scanning. Google Glass' camera lens distortions were corrected by using an image warping. Because the camera and virtual display are horizontally separated by 16 mm, and the camera aiming and virtual display projection angle are off by 10°, the warped camera image had to go through a series of three-dimensional transformations to minimize parallax errors before the final projection to the Glass' see-through virtual display. All image processes were implemented to achieve near real-time performance. The impacts of the contrast enhancements were measured for three normal-vision subjects, with and without a diffuser film to simulate vision loss. For all three subjects, significantly improved contrast sensitivity was achieved when the subjects used the edge enhancements with a diffuser film. The performance boost is limited by the Glass camera's performance. The authors assume that this accounts for why performance improvements were observed only with the diffuser filter condition (simulating low vision). Improvements were measured with simulated visual impairments. With the benefit of see-through augmented reality edge enhancement, natural visual scanning process is possible and suggests that the device may provide better visual function in a cosmetically and ergonomically attractive format for patients with macular degeneration.

  9. Prismatic displacement effect of progressive multifocal glasses on reaction time and accuracy in elderly people.

    PubMed

    Ellison, Ashton C; Campbell, A John; Robertson, M Clare; Sanderson, Gordon F

    2014-01-01

    Multifocal glasses (bifocals, trifocals, and progressives) increase the risk of falling in elderly people, but how they do so is unclear. To explain why glasses with progressive addition lenses increase the risk of falls and whether this can be attributed to false projection, this study aimed to 1) map the prismatic displacement of a progressive lens, and 2) test whether this displacement impaired reaction time and accuracy. The reaction times of healthy ≥75-year-olds (31 participants) were measured when grasping for a bar and touching a black line. Participants performed each test twice, wearing their progressives and new, matched single vision (distance) glasses in random order. The line and bar targets were positioned according to the maximum and minimum prismatic displacement effect through the progressive lens, mapped using a focimeter. Progressive spectacle lenses have large areas of prismatic displacement in the central visual axis and edges. Reaction time was faster for progressives compared with single vision glasses with a centrally-placed horizontal grab bar (mean difference 101 ms, P=0.011 [repeated measures analysis]) and a horizontal black line placed 300 mm below center (mean difference 80 ms, P=0.007). There was no difference in accuracy between the two types of glasses. Older people appear to adapt to the false projection of progressives in the central visual axis. This adaptation means that swapping to new glasses or a large change in prescription may lead to a fall. Frequently updating glasses may be more beneficial.

  10. Comparison of distance and near visual acuity in patients with vision loss due to cataract.

    PubMed

    Mercado, Carmel L; Doroslovački, Pavle; Wang, Jiangxia; Siddiqui, Aazim A; Kolker, Andrew F; Kolker, Richard J

    2017-02-01

    The purpose of this study was to assess whether there is a disparity in distance and near best-corrected visual acuity (BCVA) in cataract eyes. 102 patients with cataract (N = 121 eyes) were seen in clinic between January and November 2013 at the Wilmer Eye Institute Comprehensive Eye Service. An age-related macular degeneration (ARMD) group (N = 27 eyes) was also identified for comparison. Distance and near BCVA were measured as part of the standard ophthalmic evaluation. Snellen measurements were converted to their LogMAR equivalents for statistical analysis. Near was better than distance BCVA with mean difference of 1.38 lines (P < 0.001) in the cataract eyes. This disparity was not seen in the ARMD eyes. Near-distance BCVA disparity is a statistically significant finding seen with cataracts. This may have further implications in patients with both cataract and ARMD as the presence of disparity may suggest a cataract etiology playing a greater role in vision loss. This comparison may be useful for surgical prognostication and as a quick triage tool in conjunction with, or in place of, a potential acuity meter and dilated near-pinhole test.

  11. The Evaluation of Reading Performance with Minnesota Low Vision Reading Charts in Patients with Age-related Macular Degeneration.

    PubMed

    Altinbay, Deniz; Adibelli, Fatih Mehmet; Taskin, Ibrahim; Tekin, Adil

    2016-01-01

    To evaluate the reading performance using the Minnesota low vision reading (MNREAD) charts, of patients with age-related macular degeneration (AMD) who use low vision aid (LVA) devices. This prospective study enrolled 27 patients with AMD. Distance visual acuity (VA) was evaluated with a distance chart designed for patients with low vision. Near vision and reading performance were evaluated with the Turkish version of the MNREAD charts. Unaided vision and vision with LVA devices and high spherical add near glasses was measured. P <0.05 was considered statistically significant. The mean unaided near VA was 1.05 ± 0.27 log of the minimum angle of resolution (LogMAR). The mean VA with the LVA devices was 0.71 ± 0.41 LogMAR. Reading acuity ranged between 1.15 and 0.21 LogMAR, critical print size was between - 1.2 and 0.2 LogMAR. Maximum reading speeds were between 0 and 103 words/min. The cases are divided into groups in terms of reading speed according to age, gender, diagnosis, and education. Reading speed was negatively correlated to increasing age. MNREAD reading charts can be used to evaluate reading performance in patients with AMD with low vision. The outcomes of the present study indicate that optical correction is adequate for near VA requirements in this patient population. However, optical correction was inadequate for improving reading performance. Appropriate rehabilitation programs can be used to increase reading speed.

  12. Surgical Vision: Google Glass and Surgery.

    PubMed

    Chang, Johnny Yau Cheung; Tsui, Lok Yee; Yeung, Keith Siu Kay; Yip, Stefanie Wai Ying; Leung, Gilberto Ka Kit

    2016-08-01

    Google Glass is, in essence, a smartphone in the form of a pair of spectacles. It has a display system, a bone conduction "speaker," video camera, and connectivity via WiFi or Bluetooth technologies. It can also be controlled by voice command. Seizing Google Glass' capabilities as windows of opportunity, surgeons have been the first group of doctors trying to incorporate the technology into their daily practices. Experiences from different groups have demonstrated Google Glass' potential in improving perioperative care, intraoperative communication and documentation, surgical outcome as well as surgical training. On the other hand, the device has technical limitations, notably suboptimal image qualities and a short battery life. Its operational functions also bring forth concerns on the protection of patient privacy. Nonetheless, the technological advances that this device embodies hold promises in surgical innovations. Further studies are required, and surgeons should explore, investigate, and embrace similar technologies with keen and informed anticipation. © The Author(s) 2016.

  13. Prismatic displacement effect of progressive multifocal glasses on reaction time and accuracy in elderly people

    PubMed Central

    Ellison, Ashton C; Campbell, A John; Robertson, M Clare; Sanderson, Gordon F

    2014-01-01

    Background Multifocal glasses (bifocals, trifocals, and progressives) increase the risk of falling in elderly people, but how they do so is unclear. To explain why glasses with progressive addition lenses increase the risk of falls and whether this can be attributed to false projection, this study aimed to 1) map the prismatic displacement of a progressive lens, and 2) test whether this displacement impaired reaction time and accuracy. Methods The reaction times of healthy ≥75-year-olds (31 participants) were measured when grasping for a bar and touching a black line. Participants performed each test twice, wearing their progressives and new, matched single vision (distance) glasses in random order. The line and bar targets were positioned according to the maximum and minimum prismatic displacement effect through the progressive lens, mapped using a focimeter. Results Progressive spectacle lenses have large areas of prismatic displacement in the central visual axis and edges. Reaction time was faster for progressives compared with single vision glasses with a centrally-placed horizontal grab bar (mean difference 101 ms, P=0.011 [repeated measures analysis]) and a horizontal black line placed 300 mm below center (mean difference 80 ms, P=0.007). There was no difference in accuracy between the two types of glasses. Conclusion Older people appear to adapt to the false projection of progressives in the central visual axis. This adaptation means that swapping to new glasses or a large change in prescription may lead to a fall. Frequently updating glasses may be more beneficial. PMID:24872674

  14. A Clear Vision for Equity and Opportunity.

    ERIC Educational Resources Information Center

    Gould, Marge Christensen; Gould, Herman

    2003-01-01

    Describes undetected and uncorrected vision problems for children in poverty associated with juvenile delinquency and poor academic performance. Discusses success of a project offering vision screening and free glasses for at-risk students in Tucson, Arizona. (PKP)

  15. Adaptive Feedback in Local Coordinates for Real-time Vision-Based Motion Control Over Long Distances

    NASA Astrophysics Data System (ADS)

    Aref, M. M.; Astola, P.; Vihonen, J.; Tabus, I.; Ghabcheloo, R.; Mattila, J.

    2018-03-01

    We studied the differences in noise-effects, depth-correlated behavior of sensors, and errors caused by mapping between coordinate systems in robotic applications of machine vision. In particular, the highly range-dependent noise densities for semi-unknown object detection were considered. An equation is proposed to adapt estimation rules to dramatic changes of noise over longer distances. This algorithm also benefits the smooth feedback of wheels to overcome variable latencies of visual perception feedback. Experimental evaluation of the integrated system is presented with/without the algorithm to highlight its effectiveness.

  16. Optical needs of students with low vision in integrated schools of Nepal.

    PubMed

    Gnyawali, Subodh; Shrestha, Jyoti Baba; Bhattarai, Dipesh; Upadhyay, Madan

    2012-12-01

    To identify the optical needs of students with low vision studying in the integrated schools for the blind in Nepal. A total of 779 blind and vision-impaired students studying in 67 integrated schools for the blind across Nepal were examined using the World Health Organization/Prevention of Blindness Eye Examination Record for Children with Blindness and Low Vision. Glasses and low-vision devices were provided to the students with low vision who showed improvement in visual acuity up to a level that was considered sufficient for classroom learning. Follow-up on the use and maintenance of device provided was done after a year. Almost 78% of students studying in the integrated schools for the blind were not actually blind; they had low vision. Five students were found to be wrongly enrolled. Avoidable causes of blindness were responsible for 41% of all blindness. Among 224 students who had visual acuity 1/60 or better, distance vision could be improved in 18.7% whereas near vision could be improved in 41.1% students. Optical intervention provided improved vision in 48.2% of students who were learning braille. Only 34.8% students were found to be using the devices regularly after assessment 1 year later; the most common causes for nonuse were damage or misplacement of the device. A high proportion of students with low vision in integrated schools could benefit from optical intervention. A system of comprehensive eye examination at the time of school enrollment would allow students with low vision to use their available vision to the fullest, encourage print reading over braille, ensure appropriate placement, and promote timely adoption and proper usage of optical device.

  17. An Augmented-Reality Edge Enhancement Application for Google Glass

    PubMed Central

    Hwang, Alex D.; Peli, Eli

    2014-01-01

    Purpose Google Glass provides a platform that can be easily extended to include a vision enhancement tool. We have implemented an augmented vision system on Glass, which overlays enhanced edge information over the wearer’s real world view, to provide contrast-improved central vision to the Glass wearers. The enhanced central vision can be naturally integrated with scanning. Methods Goggle Glass’s camera lens distortions were corrected by using an image warping. Since the camera and virtual display are horizontally separated by 16mm, and the camera aiming and virtual display projection angle are off by 10°, the warped camera image had to go through a series of 3D transformations to minimize parallax errors before the final projection to the Glass’ see-through virtual display. All image processes were implemented to achieve near real-time performance. The impacts of the contrast enhancements were measured for three normal vision subjects, with and without a diffuser film to simulate vision loss. Results For all three subjects, significantly improved contrast sensitivity was achieved when the subjects used the edge enhancements with a diffuser film. The performance boost is limited by the Glass camera’s performance. The authors assume this accounts for why performance improvements were observed only with the diffuser filter condition (simulating low vision). Conclusions Improvements were measured with simulated visual impairments. With the benefit of see-through augmented reality edge enhancement, natural visual scanning process is possible, and suggests that the device may provide better visual function in a cosmetically and ergonomically attractive format for patients with macular degeneration. PMID:24978871

  18. Vision and falls in older people: risk factors and intervention strategies.

    PubMed

    Lord, Stephen R; Smith, Stuart T; Menant, Jasmine C

    2010-11-01

    Poor vision impairs balance and increases the risk of falls and fractures in older people. Multifocal glasses can add to this risk by impairing contrast sensitivity, depth perception, and ability to negotiate obstacles. Vision assessment and provision of new spectacles may not reduce, and may even increase, the risk of falls. Restriction of the use of multifocal glasses may reduce falls in active older people. Other effective fall prevention strategies include maximizing vision through cataract surgery and occupational therapy interventions in visually impaired older people. Copyright © 2010 Elsevier Inc. All rights reserved.

  19. AN INVESTIGATION OF VISION PROBLEMS AND THE VISION CARE SYSTEM IN RURAL CHINA.

    PubMed

    Bai, Yunli; Yi, Hongmei; Zhang, Linxiu; Shi, Yaojiang; Ma, Xiaochen; Congdon, Nathan; Zhou, Zhongqiang; Boswell, Matthew; Rozelle, Scott

    2014-11-01

    This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.

  20. Making Distance Education Borderless.

    ERIC Educational Resources Information Center

    Srisa-An, Wichit

    1997-01-01

    Begins with a tribute to Professor G. Ram Reddy (founder of Indira Gandhi National Open University), then focuses on enhancing the role of open universities in providing borderless distance education. Highlights include the need for open distance-education; philosophy and vision; the distance teaching system; the role of information technology;…

  1. Safety of Spectacles for Children's Vision: A Cluster-Randomized Controlled Trial.

    PubMed

    Ma, Xiaochen; Congdon, Nathan; Yi, Hongmei; Zhou, Zhongqiang; Pang, Xiaopeng; Meltzer, Mirjam E; Shi, Yaojiang; He, Mingguang; Liu, Yizhi; Rozelle, Scott

    2015-11-01

    To study safety of children's glasses in rural China, where fear that glasses harm vision is an important barrier for families and policy makers. Exploratory analysis from a cluster-randomized, investigator-masked, controlled trial. Among primary schools (n = 252) in western China, children were randomized by school to 1 of 3 interventions: free glasses provided in class, vouchers for free glasses at a local facility, or glasses prescriptions only (Control group). The main outcome of this analysis is uncorrected visual acuity after 8 months, adjusted for baseline acuity. Among 19 934 children randomly selected for screening, 5852 myopic (spherical equivalent refractive error ≤-0.5 diopters) eyes of 3001 children (14.7%, mean age 10.5 years) had VA ≤6/12 without glasses correctable to >6/12 with glasses, and were eligible. Among these, 1903 (32.5%), 1798 (30.7%), and 2151 (36.8%) were randomized to Control, Voucher, and Free Glasses, respectively. Intention-to-treat analyses were performed on all 1831 (96.2%), 1699 (94.5%), and 2007 (93.3%) eyes of children with follow-up in Control, Voucher, and Free Glasses groups. Final visual acuity for eyes of children in the treatment groups (Free Glasses and Voucher) was significantly better than for Control children, adjusting only for baseline visual acuity (difference of 0.023 logMAR units [0.23 vision chart lines, 95% CI: 0.03, 0.43]) or for other baseline factors as well (0.025 logMAR units [0.25 lines, 95% CI 0.04, 0.45]). We found no evidence that spectacles promote decline in uncorrected vision with aging among children. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Pinhole Glasses

    ERIC Educational Resources Information Center

    Colicchia, Giuseppe; Hopf, Martin; Wiesner, Hartmut; Zollman, Dean

    2008-01-01

    Eye aberrations are commonly corrected by lenses that restore vision by altering rays before they pass through the cornea. Some modern promoters claim that pinhole glasses are better than conventional lenses in correcting all kinds of refractive defects such as myopia (nearsighted), hyperopia (farsighted), astigmatisms, and presbyopia. Do pinhole…

  3. Computer vision syndrome: a study of the knowledge, attitudes and practices in Indian ophthalmologists.

    PubMed

    Bali, Jatinder; Navin, Neeraj; Thakur, Bali Renu

    2007-01-01

    To study the knowledge, attitude and practices (KAP) towards computer vision syndrome prevalent in Indian ophthalmologists and to assess whether 'computer use by practitioners' had any bearing on the knowledge and practices in computer vision syndrome (CVS). A random KAP survey was carried out on 300 Indian ophthalmologists using a 34-point spot-questionnaire in January 2005. All the doctors who responded were aware of CVS. The chief presenting symptoms were eyestrain (97.8%), headache (82.1%), tiredness and burning sensation (79.1%), watering (66.4%) and redness (61.2%). Ophthalmologists using computers reported that focusing from distance to near and vice versa (P =0.006, chi2 test), blurred vision at a distance (P =0.016, chi2 test) and blepharospasm (P =0.026, chi2 test) formed part of the syndrome. The main mode of treatment used was tear substitutes. Half of ophthalmologists (50.7%) were not prescribing any spectacles. They did not have any preference for any special type of glasses (68.7%) or spectral filters. Computer-users were more likely to prescribe sedatives/anxiolytics (P = 0.04, chi2 test), spectacles (P = 0.02, chi2 test) and conscious frequent blinking (P = 0.003, chi2 test) than the non-computer-users. All respondents were aware of CVS. Confusion regarding treatment guidelines was observed in both groups. Computer-using ophthalmologists were more informed of symptoms and diagnostic signs but were misinformed about treatment modalities.

  4. Clinical Characteristics and Low Vision Rehabilitation Methods for Partially Sighted School-Age Children

    PubMed Central

    Özen Tunay, Zuhal; Çalışkan, Deniz; İdil, Aysun; Öztuna, Derya

    2016-01-01

    Objectives: To determine the clinical features and the distribution of diagnosis in partially sighted school-age children, to report the chosen low vision rehabilitation methods and to emphasize the importance of low vision rehabilitation. Materials and Methods: The study included 150 partially sighted children between the ages of 6 and 18 years. The distribution of diagnosis, accompanying ocular findings, visual acuity of the children both for near and distance with and without low vision devices, and the methods of low vision rehabilitation (for distance and for near) were determined. The demographic characteristics of the children and the parental consanguinity were recorded. Results: The mean age of children was 10.6 years and the median age was 10 years; 88 (58.7%) of them were male and 62 (41.3%) of them were female. According to distribution of diagnoses among the children, the most frequent diagnosis was hereditary fundus dystrophies (36%) followed by cortical visual impairment (18%). The most frequently used rehabilitation methods were: telescopic lenses (91.3%) for distance vision; magnifiers (38.7%) and telemicroscopic systems (26.0%) for near vision. A significant improvement in visual acuity both for distance and near vision were determined with low vision aids. Conclusion: A significant improvement in visual acuity can be achieved both for distance and near vision with low vision rehabilitation in partially sighted school-age children. It is important for ophthalmologists and pediatricians to guide parents and children to low vision rehabilitation. PMID:27800263

  5. Clinical Characteristics and Low Vision Rehabilitation Methods for Partially Sighted School-Age Children.

    PubMed

    Özen Tunay, Zuhal; Çalışkan, Deniz; İdil, Aysun; Öztuna, Derya

    2016-04-01

    To determine the clinical features and the distribution of diagnosis in partially sighted school-age children, to report the chosen low vision rehabilitation methods and to emphasize the importance of low vision rehabilitation. The study included 150 partially sighted children between the ages of 6 and 18 years. The distribution of diagnosis, accompanying ocular findings, visual acuity of the children both for near and distance with and without low vision devices, and the methods of low vision rehabilitation (for distance and for near) were determined. The demographic characteristics of the children and the parental consanguinity were recorded. The mean age of children was 10.6 years and the median age was 10 years; 88 (58.7%) of them were male and 62 (41.3%) of them were female. According to distribution of diagnoses among the children, the most frequent diagnosis was hereditary fundus dystrophies (36%) followed by cortical visual impairment (18%). The most frequently used rehabilitation methods were: telescopic lenses (91.3%) for distance vision; magnifiers (38.7%) and telemicroscopic systems (26.0%) for near vision. A significant improvement in visual acuity both for distance and near vision were determined with low vision aids. A significant improvement in visual acuity can be achieved both for distance and near vision with low vision rehabilitation in partially sighted school-age children. It is important for ophthalmologists and pediatricians to guide parents and children to low vision rehabilitation.

  6. The crowding factor method applied to parafoveal vision

    PubMed Central

    Ghahghaei, Saeideh; Walker, Laura

    2016-01-01

    Crowding increases with eccentricity and is most readily observed in the periphery. During natural, active vision, however, central vision plays an important role. Measures of critical distance to estimate crowding are difficult in central vision, as these distances are small. Any overlap of flankers with the target may create an overlay masking confound. The crowding factor method avoids this issue by simultaneously modulating target size and flanker distance and using a ratio to compare crowded to uncrowded conditions. This method was developed and applied in the periphery (Petrov & Meleshkevich, 2011b). In this work, we apply the method to characterize crowding in parafoveal vision (<3.5 visual degrees) with spatial uncertainty. We find that eccentricity and hemifield have less impact on crowding than in the periphery, yet radial/tangential asymmetries are clearly preserved. There are considerable idiosyncratic differences observed between participants. The crowding factor method provides a powerful tool for examining crowding in central and peripheral vision, which will be useful in future studies that seek to understand visual processing under natural, active viewing conditions. PMID:27690170

  7. The contribution of stereo vision to the control of braking.

    PubMed

    Tijtgat, Pieter; Mazyn, Liesbeth; De Laey, Christophe; Lenoir, Matthieu

    2008-03-01

    In this study the contribution of stereo vision to the control of braking in front of a stationary target vehicle was investigated. Participants with normal (StereoN) and weak (StereoW) stereo vision drove a go-cart along a linear track towards a stationary vehicle. They could start braking from a distance of 4, 7, or 10m from the vehicle. Deceleration patterns were measured by means of a laser. A lack of stereo vision was associated with an earlier onset of braking, but the duration of the braking manoeuvre was similar. During the deceleration, the time of peak deceleration occurred earlier in drivers with weak stereo vision. Stopping distance was greater in those lacking in stereo vision. A lack of stereo vision was associated with a more prudent brake behaviour, in which the driver took into account a larger safety margin. This compensation might be caused either by an unconscious adaptation of the human perceptuo-motor system, or by a systematic underestimation of distance remaining due to the lack of stereo vision. In general, a lack of stereo vision did not seem to increase the risk of rear-end collisions.

  8. [Pitfalls in the prescription of reading glasses].

    PubMed

    Krause, H-K

    2011-04-01

    People in the second half of their lives often require reading glasses. A basic requirement for determining suitable reading glasses is measurement of the patient's accommodation, which describes the change in the eye's optical power caused by the attempt to clearly focus on an object at a certain distance. The maximum accommodation performance of a person already begins to decline from the age of 40 onwards. When it becomes increasingly difficult to adjust to the typical reading distance of 40 cm, one speaks of presbyopia: age-related farsightedness. This contribution describes two appropriate methods for determining the strength of reading glasses: determination of the maximum accommodation performance by measuring the near point distance and determination of the maximum accommodation effort by measuring the relative positive and negative accommodation. Optimal reading glasses enable the patient to focus sharply on something from the working distance that is closer but also on something that is further away.

  9. Fractal tomography and its application in 3D vision

    NASA Astrophysics Data System (ADS)

    Trubochkina, N.

    2018-01-01

    A three-dimensional artistic fractal tomography method that implements a non-glasses 3D visualization of fractal worlds in layered media is proposed. It is designed for the glasses-free 3D vision of digital art objects and films containing fractal content. Prospects for the development of this method in art galleries and the film industry are considered.

  10. Computer vision syndrome: a review.

    PubMed

    Blehm, Clayton; Vishnu, Seema; Khattak, Ashbala; Mitra, Shrabanee; Yee, Richard W

    2005-01-01

    As computers become part of our everyday life, more and more people are experiencing a variety of ocular symptoms related to computer use. These include eyestrain, tired eyes, irritation, redness, blurred vision, and double vision, collectively referred to as computer vision syndrome. This article describes both the characteristics and treatment modalities that are available at this time. Computer vision syndrome symptoms may be the cause of ocular (ocular-surface abnormalities or accommodative spasms) and/or extraocular (ergonomic) etiologies. However, the major contributor to computer vision syndrome symptoms by far appears to be dry eye. The visual effects of various display characteristics such as lighting, glare, display quality, refresh rates, and radiation are also discussed. Treatment requires a multidirectional approach combining ocular therapy with adjustment of the workstation. Proper lighting, anti-glare filters, ergonomic positioning of computer monitor and regular work breaks may help improve visual comfort. Lubricating eye drops and special computer glasses help relieve ocular surface-related symptoms. More work needs to be done to specifically define the processes that cause computer vision syndrome and to develop and improve effective treatments that successfully address these causes.

  11. Extended wearing trial of Trifield lens device for 'tunnel vision'.

    PubMed

    Woods, Russell L; Giorgi, Robert G; Berson, Eliot L; Peli, Eli

    2010-05-01

    Severe visual field constriction (tunnel vision) impairs the ability to navigate and walk safely. We evaluated Trifield glasses as a mobility rehabilitation device for tunnel vision in an extended wearing trial. Twelve patients with tunnel vision (5-22 degrees wide) due to retinitis pigmentosa or choroideremia participated in the 5-visit wearing trial. To expand the horizontal visual field, one spectacle lens was fitted with two apex-to-apex prisms that vertically bisected the pupil on primary gaze. This provides visual field expansion at the expense of visual confusion (two objects with the same visual direction). Patients were asked to wear these spectacles as much as possible for the duration of the wearing trial (median 8, range 6-60 weeks). Clinical success (continued wear, indicating perceived overall benefit), visual field expansion, perceived direction and perceived visual ability were measured. Of 12 patients, nine chose to continue wearing the Trifield glasses at the end of the wearing trial. Of those nine patients, at long-term follow-up (35-78 weeks), three reported still wearing the Trifield glasses. Visual field expansion (median 18, range 9-38 degrees) was demonstrated for all patients. No patient demonstrated adaptation to the change in visual direction produced by the Trifield glasses (prisms). For reported difficulty with obstacles, some differences between successful and non-successful wearers were found. Trifield glasses provided reported benefits in obstacle avoidance to 7 of the 12 patients completing the wearing trial. Crowded environments were particularly difficult for most wearers. Possible reasons for long-term discontinuation and lack of adaptation to perceived direction are discussed.

  12. Design of apochromatic lens with large field and high definition for machine vision.

    PubMed

    Yang, Ao; Gao, Xingyu; Li, Mingfeng

    2016-08-01

    Precise machine vision detection for a large object at a finite working distance (WD) requires that the lens has a high resolution for a large field of view (FOV). In this case, the effect of a secondary spectrum on image quality is not negligible. According to the detection requirements, a high resolution apochromatic objective is designed and analyzed. The initial optical structure (IOS) is combined with three segments. Next, the secondary spectrum of the IOS is corrected by replacing glasses using the dispersion vector analysis method based on the Buchdahl dispersion equation. Other aberrations are optimized by the commercial optical design software ZEMAX by properly choosing the optimization function operands. The optimized optical structure (OOS) has an f-number (F/#) of 3.08, a FOV of φ60  mm, a WD of 240 mm, and a modulated transfer function (MTF) of all fields of more than 0.1 at 320  cycles/mm. The design requirements for a nonfluorite material apochromatic objective lens with a large field and high definition for machine vision detection have been achieved.

  13. Vision Algorithms to Determine Shape and Distance for Manipulation of Unmodeled Objects

    NASA Technical Reports Server (NTRS)

    Montes, Leticia; Bowers, David; Lumia, Ron

    1998-01-01

    This paper discusses the development of a robotic system for general use in an unstructured environment. This is illustrated through pick and place of randomly positioned, un-modeled objects. There are many applications for this project, including rock collection for the Mars Surveyor Program. This system is demonstrated with a Puma560 robot, Barrett hand, Cognex vision system, and Cimetrix simulation and control, all running on a PC. The demonstration consists of two processes: vision system and robotics. The vision system determines the size and location of the unknown objects. The robotics part consists of moving the robot to the object, configuring the hand based on the information from the vision system, then performing the pick/place operation. This work enhances and is a part of the Low Cost Virtual Collaborative Environment which provides remote simulation and control of equipment.

  14. Glasses and Contact Lenses

    MedlinePlus

    ... vision problems; this includes prescribing eyeglasses and contact lenses, but also doing eye surgery for other eye-related problems. An optometrist ... them clean. The most important thing about contact lenses is good hygiene to prevent infections in your eye. But the really fun part of new glasses ...

  15. High Tech Art: Chameleon Glass

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Dichroic Glass is a technology wherein extremely thin films of metal are vacuum deposited on a glass surface. The coated glass shields spacecraft instruments from cosmic radiation and protects human vision from unfiltered sunlight in space. Because the coating process allows some wavelengths of light and color to reflect and others to pass through, a chameleon effect is produced. Murray Schwartz, a former aerospace engineer, has based his business KROMA on this NASA optical technology. He produces dichroic stained glass windows, mobiles and jewelry. The technique involves deposition of super thin layers of metal oxides applied one layer at a time in a specific order and thickness for the desired effect. His product line is unique and has been very successful.

  16. Trifocal intraocular lenses: a comparison of the visual performance and quality of vision provided by two different lens designs.

    PubMed

    Gundersen, Kjell G; Potvin, Rick

    2017-01-01

    To compare two different diffractive trifocal intraocular lens (IOL) designs, evaluating longer-term refractive outcomes, visual acuity (VA) at various distances, low contrast VA and quality of vision. Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX]) were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m), intermediate (80 and 60 cm) and near (40 cm). A binocular defocus curve was collected with the subject's best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire. Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of -1.0 D (FV better, P =0.02), -1.5 and -2.00 D (PX better, P <0.01 for both). Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm ( P <0.01) with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens ( P =0.04). There were no statistically significant differences by lens for low contrast VA ( P =0.1) or for quality of vision measures ( P >0.3). Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs.

  17. Impact of low vision rehabilitation on functional vision performance of children with visual impairment.

    PubMed

    Ganesh, Suma; Sethi, Sumita; Srivastav, Sonia; Chaudhary, Amrita; Arora, Priyanka

    2013-09-01

    To evaluate the impact of low vision rehabilitation on functional vision of children with visual impairment. The LV Prasad-Functional Vision Questionnaire, designed specifically to measure functional performance of visually impaired children of developing countries, was used to assess the level of difficulty in performing various tasks pre and post visual rehabilitation in children with documented visual impairment. Chi-square test was used to assess the impact of rehabilitation intervention on functional vision performance; a P < 0.05 was considered significant. LogMAR visual acuity prior to the introduction of low vision devices (LVDs) was 0.90 ± 0.05 for distance and for near it was 0.61 ± 0.05. After the intervention, the acuities improved significantly for distance (0.2 ± 0.27; P < 0.0001) and near (0.42 ± 0.17; P = 0.001). The most common reported difficulties were related to their academic activities like copying from the blackboard (80%), reading textbook at arm's length (77.2%), and writing along a straight line (77.2%). Absolute raw score of disability pre-LVD was 15.05 which improved to 7.58 post-LVD. An improvement in functional vision post visual rehabilitation was especially found in those activities related to their studying lifestyle like copying from the blackboard (P < 0.0001), reading textbook at arm's length (P < 0.0001), and writing along a straight line (P = 0.003). In our study group, there was a significant improvement in functional vision post visual rehabilitation, especially with those activities which are related to their academic output. It is important for these children to have an early visual rehabilitation to decrease the impairment associated with these decreased visual output and to enhance their learning abilities.

  18. Gender-related effects of vision impairment characteristics on depression in Korea.

    PubMed

    Park, Hye Won; Lee, Wanhyung; Yoon, Jin-Ha

    2018-04-01

    To investigate the gender-specific associations between perceived vision impairment and symptoms of depression. We used the data from the 2012 Korean Longitudinal Study of Aging database of 7448 individuals aged 45 years and older. Questionnaires assessing depression symptoms and perceived visual impairment at near, distance, and in general were administered. Logistic regression analyses were used to evaluate if visual impairment could lead to depression, adjusting for the potential confounders of age, socioeconomic status (household income, education level, marital status, and employment status), and health behaviors (alcohol consumption, smoking, and physical activity level) after gender stratification. Perceived general and near vision impairment were significantly associated with symptoms of depression in males (odds ratio [OR] = 2.78 and 2.54; 95% confidence interval [CI], 1.91-4.04 and 1.78-3.63). Perceived general and distance vision impairment were significantly associated with symptoms of depression in females (OR = 2.16 and 2.08; 95% CI, 1.67-2.79 and 1.61-2.69). General sight with near vision impairment in males and general sight with distance vision impairment in females could be stronger predictors of depression than other vision impairment combinations (area under the receiver operating characteristic curve [AUROC], 0.6461; p = 0.0425 in males; AUROC, 0.6270; p = 0.0318 in females). Conclusion Gender differences were found in the characteristics of visual impairment on symptoms of depression. Ophthalmologists should be aware that near vision impairment in males and distance vision impairment in females have an adjunctive effect that might contribute to symptoms of depression.

  19. Children's Glasses

    NASA Astrophysics Data System (ADS)

    Akerskog, Gunnar; Soderlund, Jan

    1980-07-01

    There is a common opinion among eye specialists and opticians that children's glasses often are not shaped for optimal fitting. A fundamental reason for this is the lack of data for the shaping of the bows, with the result that most children's glasses are reduced copies of adult's glasses. This report describes a photogrammetric method for collection of primary data for manufac-turing bows for children. An ordinary amateur camera was equipped with a stereo-adapter. With a few arrangements, such as projecting a pattern on the face and keeping the hair away from the ears, 600 children were photographed. A calibration photograph was exposed at the beginning and end of each film or when the equipment had been transported or otherwise disturbed. The photographs were measured in a stereocomparator and the coordinates analytically corrected for distortion. After determination of model coordinates the requested geometric information, such as pupillar distance, eye-ear distance, location of the bridge of the nose etc, was calculated. The shapes of average noses were presented as profile plots.

  20. A Strategic Planning Process Model for Distance Education

    ERIC Educational Resources Information Center

    Pisel, Kenneth P.

    2008-01-01

    As more institutions seek to implement or expand distance learning programs, it becomes critical to integrate distance learning programs into broader strategic visions and plans. Using the informed opinion from a panel of peer-nominated experts via iterative Delphi questionnaires, a 10-phased strategic planning process model for distance education…

  1. Chalcogenide glasses and glass-ceramics: Transparent materials in the infrared for dual applications

    NASA Astrophysics Data System (ADS)

    Calvez, Laurent

    2017-05-01

    In this paper are described the different research activities that led to the awarding of the Lamb prize by the French Academy of Sciences in order to promote research work on the national defense of France. This research concerns the development of infrared materials for night vision and the development of thermal imagers useful for defense, but also for civilian applications. The contribution has been particularly innovative in different sectors: broadening of chalcogenide glasses window of transparency, IR glass-ceramics with high thermomechanical properties, and the design of a new way of synthesis of these materials by a mechanical process.

  2. Near vision spectacle coverage and barriers to near vision correction among adults in the Cape Coast Metropolis of Ghana.

    PubMed

    Ntodie, Michael; Abu, Sampson L; Kyei, Samuel; Abokyi, Samuel; Abu, Emmanuel K

    2017-06-01

    To determine the near vision spectacle coverage and barriers to obtaining near vision correction among adults aged 35 years and older in the Cape Coast Metropolis of Ghana. A population-based cross-sectional study design was adopted and 500 out of 576 participants aged 35 years and older were examined from 12 randomly selected clusters in Cape Coast, Ghana. All participants underwent a comprehensive eye examination which included: distance and near visual acuities measurements and external and internal ocular health assessments. Distance and near refractions were performed using subjective refraction technique. Information on participants' demographics, near vision correction status, near visual needs and barriers to acquiring near vision correction were obtained through a questionnaire administered as part of the study. The mean age of participants was 52.3±10.3 years of whom 280 (56%) were females and 220 (44%) were males. The near vision spectacle coverage was 25%, 33% "met need" for near vision correction in the presbyopic population, and 64% unmet need in the entire study population. After controlling for other variables, age (5 th and 6 th decades) and educational level were associated with "met need" for near vision correction (OR=2.7 (1.55-4.68), p =0.00, and OR=2.36 (1.18-4.72), p=0.02 respectively). Among those who needed but did not have near vision correction, 64 (26%) did not feel the need for correction, 55 (22%) stated that they were unaware of available interventions, and 53 (21%) found the cost of near vision correction prohibitive. There was a low near vision spectacle coverage in this population which suggests the need for strategies on health education and promotion to address the lack of awareness of spectacle need and cost of services.

  3. INCREASED VISUAL BEHAVIOR IN LOW VISION CHILDREN.

    ERIC Educational Resources Information Center

    BARRAGA, NATALIE

    TEN PAIRS OF BLIND CHILDREN AGED SIX TO 13 YEARS WHO HAD SOME VISION WERE MATCHED BY PRETEST SCORES ON A TEST OF VISUAL DISCRIMINATION. A CRITERION GROUP, DESIGNATED THE PRINT COMPARISON GROUP, HAD SLIGHLY HIGHER RECORDED DISTANCE ACUITIES AND USED VISION AS THE PRIMARY MEANS OF LEARNING. PAIRS OF EXPERIMENTAL SUBJECTS DAILY RECEIVED 45 MINUTES OF…

  4. An egocentric vision based assistive co-robot.

    PubMed

    Zhang, Jingzhe; Zhuang, Lishuo; Wang, Yang; Zhou, Yameng; Meng, Yan; Hua, Gang

    2013-06-01

    We present the prototype of an egocentric vision based assistive co-robot system. In this co-robot system, the user is wearing a pair of glasses with a forward looking camera, and is actively engaged in the control loop of the robot in navigational tasks. The egocentric vision glasses serve for two purposes. First, it serves as a source of visual input to request the robot to find a certain object in the environment. Second, the motion patterns computed from the egocentric video associated with a specific set of head movements are exploited to guide the robot to find the object. These are especially helpful for quadriplegic individuals who do not have needed hand functionality for interaction and control with other modalities (e.g., joystick). In our co-robot system, when the robot does not fulfill the object finding task in a pre-specified time window, it would actively solicit user controls for guidance. Then the users can use the egocentric vision based gesture interface to orient the robot towards the direction of the object. After that the robot will automatically navigate towards the object until it finds it. Our experiments validated the efficacy of the closed-loop design to engage the human in the loop.

  5. Vision impairment and dual sensory problems in middle age

    PubMed Central

    Dawes, Piers; Dickinson, Christine; Emsley, Richard; Bishop, Paul; Cruickshanks, Karen; Edmondson-Jones, Mark; McCormack, Abby; Fortnum, Heather; Moore, David R.; Norman, Paul; Munro, Kevin

    2014-01-01

    Purpose Vision and hearing impairments are known to increase in middle age. In this study we describe the prevalence of vision impairment and dual sensory impairment in UK adults aged 40 to 69 years in a very large and recently ascertained data set. The associations between vision impairment, age, sex, socioeconomic status, and ethnicity are reported. Methods This research was conducted using the UK Biobank Resource, with subsets of UK Biobank data analysed with respect to self-report of eye problems and glasses use. Better-eye visual acuity with habitually worn refractive correction was assessed with a logMAR chart (n = 116,682). Better-ear speech reception threshold was measured with an adaptive speech in noise test, the Digit Triplet Test (n = 164,770). Prevalence estimates were weighted with respect to UK 2001 Census data. Results Prevalence of mild visual impairment and low vision was estimated at 15.2% (95% CI 14.9–15.5%) and 0.9% (95% CI 0.8–1.0%), respectively. Use of glasses was 88.0% (95% CI 87.9–88.1%). The prevalence of dual sensory impairment was 3.1% (95% CI 3.0–3.2%) and there was a nine-fold increase in the prevalence of dual sensory problems between the youngest and oldest age groups. Older adults, those from low socioeconomic and ethnic minority backgrounds were most at risk for vision problems. Conclusions Mild vision impairment is common in middle aged UK adults, despite widespread use of spectacles. Possible barriers to optometric care for those from low socioeconomic and ethnic minority backgrounds may require attention. A higher than expected prevalence of dual impairment suggests that hearing and vision problems share common causes. Optometrists should consider screening for hearing problems, particularly among older adults. PMID:24888710

  6. The use of contact lens telescopic systems in low vision rehabilitation.

    PubMed

    Vincent, Stephen J

    2017-06-01

    Refracting telescopes are afocal compound optical systems consisting of two lenses that produce an apparent magnification of the retinal image. They are routinely used in visual rehabilitation in the form of monocular or binocular hand held low vision aids, and head or spectacle-mounted devices to improve distance visual acuity, and with slight modifications, to enhance acuity for near and intermediate tasks. Since the advent of ground glass haptic lenses in the 1930's, contact lenses have been employed as a useful refracting element of telescopic systems; primarily as a mobile ocular lens (the eyepiece), that moves with the eye. Telescopes which incorporate a contact lens eyepiece significantly improve the weight, comesis, and field of view compared to traditional spectacle-mounted telescopes, in addition to potential related psycho-social benefits. This review summarises the underlying optics and use of contact lenses to provide telescopic magnification from the era of Descartes, to Dallos, and the present day. The limitations and clinical challenges associated with such devices are discussed, along with the potential future use of reflecting telescopes incorporated within scleral lenses and tactile contact lens systems in low vision rehabilitation. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Using an Augmented Reality Device as a Distance-based Vision Aid-Promise and Limitations.

    PubMed

    Kinateder, Max; Gualtieri, Justin; Dunn, Matt J; Jarosz, Wojciech; Yang, Xing-Dong; Cooper, Emily A

    2018-06-06

    For people with limited vision, wearable displays hold the potential to digitally enhance visual function. As these display technologies advance, it is important to understand their promise and limitations as vision aids. The aim of this study was to test the potential of a consumer augmented reality (AR) device for improving the functional vision of people with near-complete vision loss. An AR application that translates spatial information into high-contrast visual patterns was developed. Two experiments assessed the efficacy of the application to improve vision: an exploratory study with four visually impaired participants and a main controlled study with participants with simulated vision loss (n = 48). In both studies, performance was tested on a range of visual tasks (identifying the location, pose and gesture of a person, identifying objects, and moving around in an unfamiliar space). Participants' accuracy and confidence were compared on these tasks with and without augmented vision, as well as their subjective responses about ease of mobility. In the main study, the AR application was associated with substantially improved accuracy and confidence in object recognition (all P < .001) and to a lesser degree in gesture recognition (P < .05). There was no significant change in performance on identifying body poses or in subjective assessments of mobility, as compared with a control group. Consumer AR devices may soon be able to support applications that improve the functional vision of users for some tasks. In our study, both artificially impaired participants and participants with near-complete vision loss performed tasks that they could not do without the AR system. Current limitations in system performance and form factor, as well as the risk of overconfidence, will need to be overcome.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible

  8. Design of direct-vision cyclo-olefin-polymer double Amici prism for spectral imaging.

    PubMed

    Wang, Lei; Shao, Zhengzheng; Tang, Wusheng; Liu, Jiying; Nie, Qianwen; Jia, Hui; Dai, Suian; Zhu, Jubo; Li, Xiujian

    2017-10-20

    A direct-vision Amici prism is a desired dispersion element in the value of spectrometers and spectral imaging systems. In this paper, we focus on designing a direct-vision cyclo-olefin-polymer double Amici prism for spectral imaging systems. We illustrate a designed structure: E48R/N-SF4/E48R, from which we obtain 13 deg dispersion across the visible spectrum, which is equivalent to 700 line pairs/mm grating. We construct a simulative spectral imaging system with the designed direct-vision cyclo-olefin-polymer double Amici prism in optical design software and compare its imaging performance to a glass double Amici prism in the same system. The results of spot-size RMS demonstrate that the plastic prism can serve as well as their glass competitors and have better spectral resolution.

  9. Quantum vision in three dimensions

    NASA Astrophysics Data System (ADS)

    Roth, Yehuda

    We present four models for describing a 3-D vision. Similar to the mirror scenario, our models allow 3-D vision with no need for additional accessories such as stereoscopic glasses or a hologram film. These four models are based on brain interpretation rather than pure objective encryption. We consider the observer "subjective" selection of a measuring device and the corresponding quantum collapse into one of his selected states, as a tool for interpreting reality in according to the observer concepts. This is the basic concept of our study and it is introduced in the first model. Other models suggests "soften" versions that might be much easier to implement. Our quantum interpretation approach contribute to the following fields. In technology the proposed models can be implemented into real devices, allowing 3-D vision without additional accessories. Artificial intelligence: In the desire to create a machine that exchange information by using human terminologies, our interpretation approach seems to be appropriate.

  10. The role of vision for navigation in the crown-of-thorns seastar, Acanthaster planci

    PubMed Central

    Sigl, Robert; Steibl, Sebastian; Laforsch, Christian

    2016-01-01

    Coral reefs all over the Indo-Pacific suffer from substantial damage caused by the crown-of-thorns seastar Acanthaster planci, a voracious predator that moves on and between reefs to seek out its coral prey. Chemoreception is thought to guide A. planci. As vision was recently introduced as another sense involved in seastar navigation, we investigated the potential role of vision for navigation in A. planci. We estimated the spatial resolution and visual field of the compound eye using histological sections and morphometric measurements. Field experiments in a semi-controlled environment revealed that vision in A. planci aids in finding reef structures at a distance of at least 5 m, whereas chemoreception seems to be effective only at very short distances. Hence, vision outweighs chemoreception at intermediate distances. A. planci might use vision to navigate between reef structures and to locate coral prey, therefore improving foraging efficiency, especially when multidirectional currents and omnipresent chemical cues on the reef hamper chemoreception. PMID:27476750

  11. Micro Fluidic Channel Machining on Fused Silica Glass Using Powder Blasting

    PubMed Central

    Jang, Ho-Su; Cho, Myeong-Woo; Park, Dong-Sam

    2008-01-01

    In this study, micro fluid channels are machined on fused silica glass via powder blasting, a mechanical etching process, and the machining characteristics of the channels are experimentally evaluated. In the process, material removal is performed by the collision of micro abrasives injected by highly compressed air on to the target surface. This approach can be characterized as an integration of brittle mode machining based on micro crack propagation. Fused silica glass, a high purity synthetic amorphous silicon dioxide, is selected as a workpiece material. It has a very low thermal expansion coefficient and excellent optical qualities and exceptional transmittance over a wide spectral range, especially in the ultraviolet range. The powder blasting process parameters affecting the machined results are injection pressure, abrasive particle size and density, stand-off distance, number of nozzle scanning, and shape/size of the required patterns. In this study, the influence of the number of nozzle scanning, abrasive particle size, and pattern size on the formation of micro channels is investigated. Machined shapes and surface roughness are measured using a 3-dimensional vision profiler and the results are discussed. PMID:27879730

  12. NASA Synthetic Vision EGE Flight Test

    NASA Technical Reports Server (NTRS)

    Prinzel, Lawrence J.; Kramer, Lynda J.; Comstock, J. Raymond; Bailey, Randall E.; Hughes, Monica F.; Parrish, Russell V.

    2002-01-01

    NASA Langley Research Center conducted flight tests at the Eagle County, Colorado airport to evaluate synthetic vision concepts. Three display concepts (size 'A' head-down, size 'X' head-down, and head-up displays) and two texture concepts (photo, generic) were assessed for situation awareness and flight technical error / performance while making approaches to Runway 25 and Runway 07 and simulated engine-out Cottonwood 2 and KREMM departures. The results of the study confirm the retrofit capability of the HUD and Size 'A' SVS concepts to significantly improve situation awareness and performance over current EFIS glass and non-glass instruments for difficult approaches in terrain-challenged environments.

  13. Clinical and Laboratory Evaluation of Peripheral Prism Glasses for Hemianopia

    PubMed Central

    Giorgi, Robert G.; Woods, Russell L.; Peli, Eli

    2008-01-01

    Purpose Homonymous hemianopia (the loss of vision on the same side in each eye) impairs the ability to navigate and walk safely. We evaluated peripheral prism glasses as a low vision optical device for hemianopia in an extended wearing trial. Methods Twenty-three patients with complete hemianopia (13 right) with neither visual neglect nor cognitive deficit enrolled in the 5-visit study. To expand the horizontal visual field, patients’ spectacles were fitted with both upper and lower Press-On™ Fresnel prism segments (each 40 prism diopters) across the upper and lower portions of the lens on the hemianopic (“blind”) side. Patients were asked to wear these spectacles as much as possible for the duration of the study, which averaged 9 (range: 5 to 13) weeks. Clinical success (continued wear, indicating perceived overall benefit), visual field expansion, perceived direction and perceived quality of life were measured. Results Clinical Success: 14 of 21 (67%) patients chose to continue to wear the peripheral prism glasses at the end of the study (2 patients did not complete the study for non-vision reasons). At long-term follow-up (8 to 51 months), 5 of 12 (42%) patients reported still wearing the device. Visual Field Expansion: Expansion of about 22 degrees in both the upper and lower quadrants was demonstrated for all patients (binocular perimetry, Goldmann V4e). Perceived Direction: Two patients demonstrated a transient adaptation to the change in visual direction produced by the peripheral prism glasses. Quality of Life: At study end, reduced difficulty noticing obstacles on the hemianopic side was reported. Conclusions The peripheral prism glasses provided reported benefits (usually in obstacle avoidance) to 2/3 of the patients completing the study, a very good success rate for a vision rehabilitation device. Possible reasons for long-term discontinuation and limited adaptation of perceived direction are discussed. PMID:19357552

  14. A method for the prescription of inexpensive spectacles by non-specialist healthcare workers: S-Glasses

    PubMed Central

    Treacy, M P; Treacy, M G; Dimitrov, B D; Seager, F E; Stamp, M A; Murphy, C C

    2013-01-01

    Purpose Globally, 153 million people are visually impaired from uncorrected refractive error. The aim of this research was to verify a method whereby autorefractors could be used by non-specialist health-workers to prescribe spectacles, which used a small stock of preformed lenses that fit frames with standardised apertures. These spectacles were named S-Glasses (Smart Glasses). Patients and methods This prospective, single-cohort exploratory study enrolled 53 patients with 94 eligible eyes having uncorrected vision of 6/18 or worse. Eyes with best-corrected vision worse than 6/12 were excluded. An autorefractor was used to obtain refractions, which were adjusted so that eyes with astigmatism less than 2.00 dioptres (D) received spherical equivalent lenses, and eyes with more astigmatism received toric lenses with a 2.50 D cylindrical element set at one of four meridians. The primary outcome was to compare S-Glasses vision with the WHO definition of visual impairment (6/18). Where astigmatism was 2.00 D or greater, comparison with spherical equivalent was made. Mixed-model analysis with repeated effect was used to account for possible correlation between the vision of fellow eyes of the same individual. Results S-Glasses corrected 100% of eyes with astigmatism less than 3.00 D and 69% of eyes with astigmatism of 3.00 D or greater. Spherical equivalent lenses corrected 25% of eyes with astigmatism of 2.00−2.99 D and 11% with astigmatism of at least 3.00 D. Discussion S-Glasses could be beneficial to resource-poor populations without trained refractionists. This novel approach, using approximate toric lenses, results in superior vision for astigmatic patients compared with the practice of providing spherical equivalent alone. PMID:23306732

  15. Vision training methods for sports concussion mitigation and management.

    PubMed

    Clark, Joseph F; Colosimo, Angelo; Ellis, James K; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon

    2015-05-05

    There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock's string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention.

  16. Vision Training Methods for Sports Concussion Mitigation and Management

    PubMed Central

    Clark, Joseph F.; Colosimo, Angelo; Ellis, James K.; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon

    2015-01-01

    There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock’s string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention. PMID:25992878

  17. Changes in accommodation and ocular aberration with simultaneous vision multifocal contact lenses.

    PubMed

    Ruiz-Alcocer, Javier; Madrid-Costa, David; Radhakrishnan, Hema; Ferrer-Blasco, Teresa; Montés-Micó, Robert

    2012-09-01

    The aim of this study was to evaluate ocular aberration changes through different simultaneous vision multifocal contact lenses (CLs). Eighteen young-adult subjects with a mean age of 29.8±2.11 years took part. Changes in accommodative response, spherical aberration (C(4)(0)), horizontal coma (C(3)(1)), vertical coma (C(3)(-1)), and root mean square (RMS) of higher-order aberrations (HOAs, third to sixth orders) were evaluated. Measurements were obtained with a distance-single vision CL and 2 aspheric multifocal CLs of simultaneous focus center-near design (PureVision Low Add and PureVision High Add) for 2 accommodative stimuli (-2.50 and -4.00 D). All measurements were performed monocularly with a Hartmann-Shack aberrometer (IRX-3; Imagine Eyes, Orsay, France). No statistically significant differences were found in accommodative responses to -2.50- and -4.00-D stimuli between the single vision CL and the 2 multifocal CLs. Spherical aberration was found to decrease and become more negative with accommodation for both stimuli with all three CLs. Horizontal coma decreased significantly with accommodation (-2.5- and -4.00-D stimuli) for the distance-single vision CLs (P=0.002 and P=0.003). No differences were found in vertical coma Zernike coefficients. The RMS of HOAs was found to decrease only with the single vision CLs for both stimuli (P<0.01). Data obtained in this study suggest that in young subjects, the multifocal CLs studied do not induce large changes in accommodative response compared with the distance-single vision CLs. Spherical aberration reduced significantly with accommodation.

  18. Tin Valence and Local Environments in Silicate Glasses as Determined From X-ray Absorption Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKeown,D.; Buechele, A.; Gan, H.

    2008-01-01

    X-ray absorption spectroscopy (XAS) was used to characterize the tin (Sn) environments in four borosilicate glass nuclear waste formulations, two silicate float glasses, and three potassium aluminosilicate glasses. Sn K-edge XAS data of most glasses investigated indicate Sn4+O6 units with average Sn-O distances near 2.03 Angstroms. XAS data for a float glass fabricated under reducing conditions show a mixture of Sn4+O6 and Sn2+O4 sites. XAS data for three glasses indicate Sn-Sn distances ranging from 3.43 to 3.53 Angstroms, that suggest Sn4+O6 units linking with each other, while the 4.96 Angstroms Sn-Sn distance for one waste glass suggests clustering of unlinkedmore » Sn4+O6 units.« less

  19. X-Ray Absorption Spectroscopy Studies of the Atomic Structure of Zirconium-Doped Lithium Silicate Glasses and Glass-Ceramics, Zirconium-Doped Lithium Borate Glasses, and Vitreous Rare-Earth Phosphates

    NASA Astrophysics Data System (ADS)

    Yoo, Changhyeon

    In the first part of this work, the atomic-scale structure around rare-earth (RE = Pr, Nd, Eu, Dy, and Er) cations (RE3+) in rare-earth sodium ultraphosphate (REUP) glasses were investigated using RE LIII -edge (RE = Nd, Er, Dy, and Eu) and K-edge (RE = Pr and Dy) Extended X-ray Absorption Fine Structure (EXAFS) spectroscopy. (RE2O 3)x(Na2O)y(P2O5) 1-x-y glasses in the compositional range 0 ≤ x ≤ 0.14 and 0.3 ≤ x + y ≤ 0.4 were studied. For the nearest oxygen shell, the RE-oxygen (RE-O) coordination number decreases from 10.8 to 6.5 with increasing RE content for Pr-, Nd-, Dy-, and Er-doped sodium ultraphosphate glasses. For Eu-doped samples, the Eu-O coordination number was between 7.5 and 8.8. Also, the RE-O mean distance ranges were between 2.43-2.45 A, 2.40-2.43 A, 2.36-2.38 A, 2.30-2.35 A, and 2.28-2.30 A for Pr-, Nd-, Eu-, Dy-, and Er-doped samples, respectively. In the second part, a series of Zr-doped (3-10 mol%) lithium silicate (ZRLS) glass-ceramics and their parent glasses and a series of Zr-doped (2-6 mol% ZrO2) lithium borate (ZRLB) glasses were investigated using Zr K-edge EXAFS and X-ray Absorption Near Edge Structure (XANES) spectroscopy. Immediate coordination environments of all ZRLS glasses are remarkably similar for different compositions. For the nearest oxygen shell, the Zr-O coordination number ranges were between 6.1 and 6.3 for nucleated and crystallized samples, respectively. Also, the Zr-O mean distance remains similar around 2.10 A. For these glasses, the composition dependence of structural parameters was small. Small changes in the coordination environment were observed for ZRLS glass-ceramics after thermal treatments. In contrast, Zr coordination environment in ZRLB glasses appear to depend appreciably on the Zr concentration. For the nearest oxygen shell, the Zr-O coordination number increased from 6.1 to 6.8 and the Zr-O distance decreased from 2.18 A to 2.14 A with decreasing ZrO2 content.

  20. A Simple Demonstration for Estimating the Persistence of Vision

    ERIC Educational Resources Information Center

    MacInnes, Iain; Smith, Stuart

    2010-01-01

    In the "The Science Study Series" book "The Physics of Television", it is stated that persistence of vision lasts for about a tenth of a second. This will be a notional figure just as 25 cm is taken to be the least distance of distinct vision. Estimates range from 1/8 to 1/16 s.

  1. Small or far away? Size and distance perception in the praying mantis

    PubMed Central

    Bissianna, Geoffrey

    2016-01-01

    Stereo or ‘3D’ vision is an important but costly process seen in several evolutionarily distinct lineages including primates, birds and insects. Many selective advantages could have led to the evolution of stereo vision, including range finding, camouflage breaking and estimation of object size. In this paper, we investigate the possibility that stereo vision enables praying mantises to estimate the size of prey by using a combination of disparity cues and angular size cues. We used a recently developed insect 3D cinema paradigm to present mantises with virtual prey having differing disparity and angular size cues. We predicted that if they were able to use these cues to gauge the absolute size of objects, we should see evidence for size constancy where they would strike preferentially at prey of a particular physical size, across a range of simulated distances. We found that mantises struck most often when disparity cues implied a prey distance of 2.5 cm; increasing the implied distance caused a significant reduction in the number of strikes. We, however, found no evidence for size constancy. There was a significant interaction effect of the simulated distance and angular size on the number of strikes made by the mantis but this was not in the direction predicted by size constancy. This indicates that mantises do not use their stereo vision to estimate object size. We conclude that other selective advantages, not size constancy, have driven the evolution of stereo vision in the praying mantis. This article is part of the themed issue ‘Vision in our three-dimensional world’. PMID:27269605

  2. Agnosic vision is like peripheral vision, which is limited by crowding.

    PubMed

    Strappini, Francesca; Pelli, Denis G; Di Pace, Enrico; Martelli, Marialuisa

    2017-04-01

    Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it

  3. Development and validation of a vision-specific quality-of-life questionnaire for Timor-Leste.

    PubMed

    du Toit, Rènée; Palagyi, Anna; Ramke, Jacqueline; Brian, Garry; Lamoureux, Ecosse L

    2008-10-01

    To develop and determine the reliability and validity of a vision-specific quality-of-life instrument (TL-VSQOL) designed to assess the impact of distance and near vision impairment in adults living in Timor-Leste. A vision-specific quality-of-life questionnaire was developed, piloted, and administered to 704 Timorese aged >or=40 years during a population-based eye health rapid assessment. Rasch analysis was performed on the data of 457 participants with presenting near vision worse than N8 (78.5%) and/or distance vision worse than 6/18 (69.8%). Unidimensionality, item fit to the model, response category performance, differential item functioning, and targeting of items to participants were assessed. Initially, the questionnaire lacked fit to the Rasch model. Removal of two items concerning emotional well-being resulted in a fit of the data (overall item-trait interaction: chi(2) (df) = 81 (51); mean (SD) person and item fit residual values: -0.30 (1.02) and -0.32 (1.46), and good targeting of person ability and item difficulty was evident. Poorer distance and near visual acuities were significantly associated with worse quality-of-life scores (P < 0.001). Person separation reliability was substantial (0.93), indicating that the instrument can discriminate between groups with normal and impaired vision. All 17 items were free of differential item functioning, and there was no evidence of multidimensionality. This 17-item TL-VSQOL has high reliability, construct, and criterion validity and effective targeting. It can effectively assess the impact on quality of life of adult Timorese with distance and near vision impairment. The TL-VSQOL could be adapted for use in other low-resource settings.

  4. Outcomes of an inner-city vision outreach program: give kids sight day.

    PubMed

    Dotan, Gad; Truong, Billy; Snitzer, Melanie; McCauley, Colleen; Martinez-Helfman, Sarah; Santa Maria, Kathy; Levin, Alex V

    2015-05-01

    Low-socioeconomic urban children often do not have access to ophthalmic care. To characterize the demographic characteristics and ophthalmic conditions in children attending Give Kids Sight Day (GKSD), an outreach ophthalmic care program held annually in Philadelphia, Pennsylvania, providing vision screening and immediate treatment when needed. Retrospective case-series study of children attending GKSD in 2012 (GKSD 2012) at an ophthalmology center in Philadelphia. Registration forms and records of all children attending GKSD 2012 were reviewed. Demographic characteristics, insurance status, spoken languages, reasons for attending, prior failure of vision screening, and attendance pattern of previous events were analyzed. The ophthalmological findings of these children were examined, including refractive errors, need for optical correction, and diagnoses for which continuous ophthalmic care was necessary. For children who needed ophthalmic follow-up, the rate of return to clinic and barriers for continuous care were analyzed. We studied 924 children (mean age, 9 years; age range, 0-18 years; 51% female; 25% speaking a non-English language) coming from 584 families who attended GKSD 2012, of whom 27% were uninsured and 10% were not aware of their insurance status. Forty-two percent of participants had public insurance, which covered vision care and glasses, but 35% did not know their benefits and did not realize vision care was covered. Forty-nine percent of children attended because they failed community vision screening. Provision of free glasses and failure of previous vision screening were the most common reasons families elected to attend GKSD (64% and 49%, respectively). Eighty-five percent of children attended GKSD 2012 for the first time, whereas 15% attended prior events. Glasses were provided to 61% of attendees. Ten percent of the attendees needed continuous ophthalmic care, most commonly for amblyopia. Ten children needed ocular surgery for cataract

  5. Comparison of progressive addition lenses for general purpose and for computer vision: an office field study.

    PubMed

    Jaschinski, Wolfgang; König, Mirjam; Mekontso, Tiofil M; Ohlendorf, Arne; Welscher, Monique

    2015-05-01

    Two types of progressive addition lenses (PALs) were compared in an office field study: 1. General purpose PALs with continuous clear vision between infinity and near reading distances and 2. Computer vision PALs with a wider zone of clear vision at the monitor and in near vision but no clear distance vision. Twenty-three presbyopic participants wore each type of lens for two weeks in a double-masked four-week quasi-experimental procedure that included an adaptation phase (Weeks 1 and 2) and a test phase (Weeks 3 and 4). Questionnaires on visual and musculoskeletal conditions as well as preferences regarding the type of lenses were administered. After eight more weeks of free use of the spectacles, the preferences were assessed again. The ergonomic conditions were analysed from photographs. Head inclination when looking at the monitor was significantly lower by 2.3 degrees with the computer vision PALs than with the general purpose PALs. Vision at the monitor was judged significantly better with computer PALs, while distance vision was judged better with general purpose PALs; however, the reported advantage of computer vision PALs differed in extent between participants. Accordingly, 61 per cent of the participants preferred the computer vision PALs, when asked without information about lens design. After full information about lens characteristics and additional eight weeks of free spectacle use, 44 per cent preferred the computer vision PALs. On average, computer vision PALs were rated significantly better with respect to vision at the monitor during the experimental part of the study. In the final forced-choice ratings, approximately half of the participants preferred either the computer vision PAL or the general purpose PAL. Individual factors seem to play a role in this preference and in the rated advantage of computer vision PALs. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  6. Water diffusion in silicate glasses: the effect of glass structure

    NASA Astrophysics Data System (ADS)

    Kuroda, M.; Tachibana, S.

    2016-12-01

    Water diffusion in silicate melts (glasses) is one of the main controlling factors of magmatism in a volcanic system. Water diffusivity in silicate glasses depends on its own concentration. However, the mechanism causing those dependences has not been fully understood yet. In order to construct a general model for water diffusion in various silicate glasses, we performed water diffusion experiments in silica glass and proposed a new water diffusion model [Kuroda et al., 2015]. In the model, water diffusivity is controlled by the concentration of both main diffusion species (i.e. molecular water) and diffusion pathways, which are determined by the concentrations of hydroxyl groups and network modifier cations. The model well explains the water diffusivity in various silicate glasses from silica glass to basalt glass. However, pre-exponential factors of water diffusivity in various glasses show five orders of magnitude variations although the pre-exponential factor should ideally represent the jump frequency and the jump distance of molecular water and show a much smaller variation. Here, we attribute the large variation of pre-exponential factors to a glass structure dependence of activation energy for molecular water diffusion. It has been known that the activation energy depends on the water concentration [Nowak and Behrens, 1997]. The concentration of hydroxyls, which cut Si-O-Si network in the glass structure, increases with water concentration, resulting in lowering the activation energy for water diffusion probably due to more fragmented structure. Network modifier cations are likely to play the same role as water. With taking the effect of glass structure into account, we found that the variation of pre-exponential factors of water diffusivity in silicate glasses can be much smaller than the five orders of magnitude, implying that the diffusion of molecular water in silicate glasses is controlled by the same atomic process.

  7. Low vision in east African blind school students: need for optical low vision services.

    PubMed

    Silver, J; Gilbert, C E; Spoerer, P; Foster, A

    1995-09-01

    There is increasing awareness of the needs of children with low vision, particularly in developing countries where programmes of integrated education are being developed. However, appropriate low vision services are usually not available or affordable. The aims of this study were, firstly, to assess the need for spectacles and optical low vision devices in students with low vision in schools for the blind in Kenya and Uganda; secondly, to evaluate inexpensive locally produced low vision devices; and, finally, to evaluate simple methods of identifying those low vision students who could read N5 to N8 print after low vision assessment. A total of 230 students were examined (51 school and 16 university students in Uganda and 163 students in Kenya, aged 5-22 years), 147 of whom had a visual acuity of less than 6/18 to perception of light in the better eye at presentation. After refraction seven of the 147 achieved 6/18 or better. Eighty two (58.6%) of the 140 students with low vision (corrected visual acuity in the better eye of less than 6/18 to light perception) had refractive errors of more than 2 dioptres in the better eye, and 38 (27.1%) had more than 2 dioptres of astigmatism. Forty six per cent of students with low vision (n = 64) could read N5-N8 print unaided or with spectacles, as could a further 33% (n = 46) with low vision devices. Low vision devices were indicated in a total of 50 students (35.7%). The locally manufactured devices could meet two thirds of the need. A corrected distance acuity of 1/60 or better had a sensitivity of 99.1% and a specificity of 56.7% in predicting the ability to discern N8 print or better. The ability to perform at least two of the three simple tests of functional vision had a sensitivity of 95.5% and a specificity of 63.3% in identifying the students able to discern N8 or better.

  8. Vehicle-based vision sensors for intelligent highway systems

    NASA Astrophysics Data System (ADS)

    Masaki, Ichiro

    1989-09-01

    This paper describes a vision system, based on ASIC (Application Specific Integrated Circuit) approach, for vehicle guidance on highways. After reviewing related work in the fields of intelligent vehicles, stereo vision, and ASIC-based approaches, the paper focuses on a stereo vision system for intelligent cruise control. The system measures the distance to the vehicle in front using trinocular triangulation. An application specific processor architecture was developed to offer low mass-production cost, real-time operation, low power consumption, and small physical size. The system was installed in the trunk of a car and evaluated successfully on highways.

  9. Development of a vision-targeted health-related quality of life item measure

    PubMed Central

    Slotkin, Jerry; McKean-Cowdin, Roberta; Lee, Paul; Owsley, Cynthia; Vitale, Susan; Varma, Rohit; Gershon, Richard; Hays, Ron D.

    2013-01-01

    Purpose To develop a vision-targeted health-related quality of life (HRQOL) measure for the NIH Toolbox for the Assessment of Neurological and Behavioral Function. Methods We conducted a review of existing vision-targeted HRQOL surveys and identified color vision, low luminance vision, distance vision, general vision, near vision, ocular symptoms, psychosocial well-being, and role performance domains. Items in existing survey instruments were sorted into these domains. We selected non-redundant items and revised them to improve clarity and to limit the number of different response options. We conducted 10 cognitive interviews to evaluate the items. Finally, we revised the items and administered them to 819 individuals to calibrate the items and estimate the measure’s reliability and validity. Results The field test provided support for the 53-item vision-targeted HRQOL measure encompassing 6 domains: color vision, distance vision, near vision, ocular symptoms, psychosocial well-being, and role performance. The domain scores had high levels of reliability (coefficient alphas ranged from 0.848 to 0.940). Validity was supported by high correlations between National Eye Institute Visual Function Questionnaire scales and the new-vision-targeted scales (highest values were 0.771 between psychosocial well-being and mental health, and 0.729 between role performance and role difficulties), and by lower mean scores in those groups self-reporting eye disease (F statistic with p < 0.01 for all comparisons except cataract with ocular symptoms, psychosocial well-being, and role performance scales). Conclusions This vision-targeted HRQOL measure provides a basis for comprehensive assessment of the impact of eye diseases and treatments on daily functioning and well-being in adults. PMID:23475688

  10. Remote logo detection using angle-distance histograms

    NASA Astrophysics Data System (ADS)

    Youn, Sungwook; Ok, Jiheon; Baek, Sangwook; Woo, Seongyoun; Lee, Chulhee

    2016-05-01

    Among all the various computer vision applications, automatic logo recognition has drawn great interest from industry as well as various academic institutions. In this paper, we propose an angle-distance map, which we used to develop a robust logo detection algorithm. The proposed angle-distance histogram is invariant against scale and rotation. The proposed method first used shape information and color characteristics to find the candidate regions and then applied the angle-distance histogram. Experiments show that the proposed method detected logos of various sizes and orientations.

  11. Stepping on Obstacles with a Sensory Substitution Device on the Lower Leg: Practice without Vision Is More Beneficial than Practice with Vision

    PubMed Central

    Lobo, Lorena; Travieso, David; Barrientos, Antonio; Jacobs, David M.

    2014-01-01

    Practice is essential for an adapted use of sensory substitution devices. Understanding the learning process is therefore a fundamental issue in this field of research. This study presents a novel sensory substitution device worn on the lower leg and uses the device to study learning. The device includes 32 vibrotactile actuators that each vibrate as a function of the distance to the nearest surface in a particular direction. Participants wearing the device were asked to approach an object and to step on the object. Two 144-trial practice conditions were compared in a pretest-practice-posttest design. Participants in the first condition practiced with vibrotactile stimulation while blindfolded. Participants in the second condition practiced with vibrotactile stimulation along with normal vision. Performance was relatively successful, both types of practice led to improvements in performance, and practice without vision led to a larger reduction in the number of errors than practice with vision. These results indicate that distance-based sensory substitution is promising in addition to the more traditional light-intensity-based sensory substitution and that providing appropriate sensorimotor couplings is more important than applying the stimulation to highly sensitive body parts. The observed advantage of practice without vision over practice with vision is interpreted in terms of the guidance hypothesis of feedback and learning. PMID:24901843

  12. Quality of life and near vision impairment due to functional presbyopia among rural Chinese adults.

    PubMed

    Lu, Qing; Congdon, Nathan; He, Xiangdong; Murthy, Gudlavalleti V S; Yang, Amy; He, Wei

    2011-06-13

    To evaluate the impact of near-vision impairment on visual functioning and quality of life in a rural adult population in Shenyang, northern China. A population-based, cross-sectional study was conducted among persons aged 40+ years, during which functional presbyopia (correctable presenting near vision < 20/50 [N8] at 40 cm) was assessed. Near-vision-related quality of life and spectacle usage questionnaires were administered by trained interviewers to determine the degree of self-rated difficulty with near tasks. A total of 1008 respondents (91.5% of 1102 eligible persons) were examined, and 776 (78%) of completed the questionnaires (mean age, 57.0 ± 10.2 years; 63.3% women). Near-vision spectacle wearers obtained their spectacles primarily from markets (74.5%) and optical shops (21.7%), and only 1.14% from eye clinics. Among 538 (69.3%) persons with functional presbyopia, self-rated overall (distance and near) vision was worse (P < 0.001) and difficulty with activities of daily living greater (P < 0.001) than among nonpresbyopes. Odds of reporting any difficulty with daily tasks remained higher (OR = 2.32; P < 0.001) for presbyopes after adjustment for age, sex, education and distance vision. Compared to persons without presbyopia, presbyopic persons were more likely to report diminished accomplishment due to vision (P = 0.01, adjusted for age, sex, education, and distance vision.) Difficulties with activities of daily living and resulting social impediments are common due to presbyopia in this setting. Most spectacle wearers with presbyopia in rural China obtain near correction from sources that do not provide comprehensive vision care.

  13. Reliable vision-guided grasping

    NASA Technical Reports Server (NTRS)

    Nicewarner, Keith E.; Kelley, Robert B.

    1992-01-01

    Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.

  14. A Retrospective Study of Causes of Low Vision in Saud Arabia, A Case of Eye World Medical Complex in Riyadh.

    PubMed

    Z Alotaibi, Abdullah

    2015-10-20

    Vision is the ability of seeing with a definite understanding of features, color and contrast, and to distinguish between objects visually. In the year 1999, the World Health Organization (WHO) and the International Agency for the Prevention of Blindness formulated a worldwide project for the eradication of preventable loss of sight with the subject of "Vision 2020: the Right to Sight". This global program aims to eradicate preventable loss of sight by the year 2020. This study was conducted to determine the main causes of low vision in Saudi Arabia and also to assess their visual improvement after using low vision aids (LVD).The study is a retrospective study and was conducted in low vision clinic at Eye World Medical Complex in Riyadh, Saudi Arabia. The file medical record of 280 patients attending low vision clinics from February 2008 to June 2010 was included. A data sheet was filled which include: age, gender, cause of low vision, unassisted visual acuity for long distances and short distances, low vision devices needed for long distances and short distances that provides best visual acuity. The result shows that the main cause of low vision was Optic atrophy (28.9%). Retinitis pigmentosa was the second cause of low vision, accounting for 73 patients (26%) followed by Diabetic retinopathy and Macular degeneration with 44 patients (15.7%) and 16 patients (5.7%) respectively. Inter family marriage could be one of the main causes of low vision. Public awareness should be embarked on for enlightenment on ocular diseases result in consanguineous marriage. Also, it is an important issue to start establishing low vision clinics in order to improve the situation.

  15. Individual Objective and Subjective Fixation Disparity in Near Vision

    PubMed Central

    Jaschinski, Wolfgang

    2017-01-01

    Binocular vision refers to the integration of images in the two eyes for improved visual performance and depth perception. One aspect of binocular vision is the fixation disparity, which is a suboptimal condition in individuals with respect to binocular eye movement control and subsequent neural processing. The objective fixation disparity refers to the vergence angle between the visual axes, which is measured with eye trackers. Subjective fixation disparity is tested with two monocular nonius lines which indicate the physical nonius separation required for perceived alignment. Subjective and objective fixation disparity represent the different physiological mechanisms of motor and sensory fusion, but the precise relation between these two is still unclear. This study measures both types of fixation disparity at viewing distances of 40, 30, and 24 cm while observers fixated a central stationary fusion target. 20 young adult subjects with normal binocular vision were tested repeatedly to investigate individual differences. For heterophoria and subjective fixation disparity, this study replicated that the binocular system does not properly adjust to near targets: outward (exo) deviations typically increase as the viewing distance is shortened. This exo proximity effect—however—was not found for objective fixation disparity, which–on the average–was zero. But individuals can have reliable outward (exo) or inward (eso) vergence errors. Cases with eso objective fixation disparity tend to have less exo states of subjective fixation disparity and heterophoria. In summary, the two types of fixation disparity seem to respond in a different way when the viewing distance is shortened. Motor and sensory fusion–as reflected by objective and subjective fixation disparity–exhibit complex interactions that may differ between individuals (eso versus exo) and vary with viewing distance (far versus near vision). PMID:28135308

  16. Vision-Based UAV Flight Control and Obstacle Avoidance

    DTIC Science & Technology

    2006-01-01

    denoted it by Vb = (Vb1, Vb2 , Vb3). Fig. 2 shows the block diagram of the proposed vision-based motion analysis and obstacle avoidance system. We denote...structure analysis often involve computation- intensive computer vision tasks, such as feature extraction and geometric modeling. Computation-intensive...First, we extract a set of features from each block. 2) Second, we compute the distance between these two sets of features. In conventional motion

  17. Vision related quality of life in spinocerebellar ataxia.

    PubMed

    Kedar, Sachin; Ghate, Deepta; Murray, Earnest L; Corbett, James J; Subramony, S H

    2015-11-15

    Spinocerebellar ataxia (SCA) leads to abnormal ocular motility and alignment. The objective of this study was to quantitatively assess vision, ocular motility and alignment and its impact on vision related quality of life (VRQOL) in SCA. Nineteen genetically diagnosed SCA subjects (11 SCA type 3, 3 SCA type 1 and 5 SCA type 6) participated at two university centers. All subjects completed the National Eye Institute Visual Function Questionnaire (NEI-VFQ), 10-Item Neuro-Ophthalmic Supplement (NOS), scale for assessment and rating of ataxia (SARA) and ophthalmic examination. Twelve subjects seen at one of the 2 sites underwent quantitative ocular motility and alignment assessment. Composite scores for NEI-VFQ (mean 76.3±13) and NOS (mean 65.2±16.8) were significantly decreased in SCA subjects. NEI-VFQ subscale scores were decreased for general, near, distance and peripheral vision and driving. SCA patients had decreased low contrast sensitivity, stereoacuity and multiple ocular motility defects which included gaze limitation (9/12), nystagmus (5/12), distance esophoria (11/12), near exophoria (12/12) and receded near point of convergence. A significant negative correlation was noted between composite scores and distance convergence fusional amplitude. VRQOL is significantly decreased in SCA compared to normal population. All SCA patients should be screened for visual disability and referred for neuro-ophthalmic assessment promptly. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Strategies to improve the accuracy of vision measurement by teachers in rural Chinese secondary schoolchildren: Xichang Pediatric Refractive Error Study (X-PRES) report no. 6.

    PubMed

    Sharma, Abhishek; Li, Liping; Song, Yue; Choi, Kai; Lam, Dennis S C; Zhang, Mingzhi; Zheng, Mingwei; Zhou, Zhongxia; Liu, Xiaojian; Wu, Bin; Congdon, Nathan

    2008-10-01

    To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.

  19. Simplification of Visual Rendering in Simulated Prosthetic Vision Facilitates Navigation.

    PubMed

    Vergnieux, Victor; Macé, Marc J-M; Jouffrais, Christophe

    2017-09-01

    Visual neuroprostheses are still limited and simulated prosthetic vision (SPV) is used to evaluate potential and forthcoming functionality of these implants. SPV has been used to evaluate the minimum requirement on visual neuroprosthetic characteristics to restore various functions such as reading, objects and face recognition, object grasping, etc. Some of these studies focused on obstacle avoidance but only a few investigated orientation or navigation abilities with prosthetic vision. The resolution of current arrays of electrodes is not sufficient to allow navigation tasks without additional processing of the visual input. In this study, we simulated a low resolution array (15 × 18 electrodes, similar to a forthcoming generation of arrays) and evaluated the navigation abilities restored when visual information was processed with various computer vision algorithms to enhance the visual rendering. Three main visual rendering strategies were compared to a control rendering in a wayfinding task within an unknown environment. The control rendering corresponded to a resizing of the original image onto the electrode array size, according to the average brightness of the pixels. In the first rendering strategy, vision distance was limited to 3, 6, or 9 m, respectively. In the second strategy, the rendering was not based on the brightness of the image pixels, but on the distance between the user and the elements in the field of view. In the last rendering strategy, only the edges of the environments were displayed, similar to a wireframe rendering. All the tested renderings, except the 3 m limitation of the viewing distance, improved navigation performance and decreased cognitive load. Interestingly, the distance-based and wireframe renderings also improved the cognitive mapping of the unknown environment. These results show that low resolution implants are usable for wayfinding if specific computer vision algorithms are used to select and display appropriate

  20. Solid oxide fuel cell having a glass composite seal

    DOEpatents

    De Rose, Anthony J.; Mukerjee, Subhasish; Haltiner, Jr., Karl Jacob

    2013-04-16

    A solid oxide fuel cell stack having a plurality of cassettes and a glass composite seal disposed between the sealing surfaces of adjacent cassettes, thereby joining the cassettes and providing a hermetic seal therebetween. The glass composite seal includes an alkaline earth aluminosilicate (AEAS) glass disposed about a viscous glass such that the AEAS glass retains the viscous glass in a predetermined position between the first and second sealing surfaces. The AEAS glass provides geometric stability to the glass composite seal to maintain the proper distance between the adjacent cassettes while the viscous glass provides for a compliant and self-healing seal. The glass composite seal may include fibers, powders, and/or beads of zirconium oxide, aluminum oxide, yttria-stabilized zirconia (YSZ), or mixtures thereof, to enhance the desirable properties of the glass composite seal.

  1. Effect of Viewing Plane on Perceived Distances in Real and Virtual Environments

    ERIC Educational Resources Information Center

    Geuss, Michael N.; Stefanucci, Jeanine K.; Creem-Regehr, Sarah H.; Thompson, William B.

    2012-01-01

    Three experiments examined perceived absolute distance in a head-mounted display virtual environment (HMD-VE) and a matched real-world environment, as a function of the type and orientation of the distance viewed. In Experiment 1, participants turned and walked, without vision, a distance to match the viewed interval for both egocentric…

  2. Detection algorithm for glass bottle mouth defect by continuous wavelet transform based on machine vision

    NASA Astrophysics Data System (ADS)

    Qian, Jinfang; Zhang, Changjiang

    2014-11-01

    An efficient algorithm based on continuous wavelet transform combining with pre-knowledge, which can be used to detect the defect of glass bottle mouth, is proposed. Firstly, under the condition of ball integral light source, a perfect glass bottle mouth image is obtained by Japanese Computar camera through the interface of IEEE-1394b. A single threshold method based on gray level histogram is used to obtain the binary image of the glass bottle mouth. In order to efficiently suppress noise, moving average filter is employed to smooth the histogram of original glass bottle mouth image. And then continuous wavelet transform is done to accurately determine the segmentation threshold. Mathematical morphology operations are used to get normal binary bottle mouth mask. A glass bottle to be detected is moving to the detection zone by conveyor belt. Both bottle mouth image and binary image are obtained by above method. The binary image is multiplied with normal bottle mask and a region of interest is got. Four parameters (number of connected regions, coordinate of centroid position, diameter of inner cycle, and area of annular region) can be computed based on the region of interest. Glass bottle mouth detection rules are designed by above four parameters so as to accurately detect and identify the defect conditions of glass bottle. Finally, the glass bottles of Coca-Cola Company are used to verify the proposed algorithm. The experimental results show that the proposed algorithm can accurately detect the defect conditions of the glass bottles and have 98% detecting accuracy.

  3. Internet Use and Television Viewing in Children and its Association with Vision Loss: A Major Public Health Problem.

    PubMed

    Bener, Abdulbari; Al-Mahdi, Huda S

    2012-03-07

    Little is known about the distribution of eye and vision conditions among school children in Qatar. The aim of the study was to examine the effects of excessive internet use and television viewing on low vision and its prevalence with socio-demographic characteristics. This is a cross-sectional study which was carried out in the public and private schools of the Ministry of Education and Higher Education of the State of Qatar from September 2009 to April 2010. A total of 3200 students aged 6-18 years were invited to take part of whom 2586 (80.8%) agreed. A questionnaire, that included questions about socio-demographic factors, internet use, and television viewing and computer games, co-morbid factors, and family history and vision assessment, was designed to collect information from the students. This was distributed by the school authorities. Of the school children studied (n=2586), 52.8% were girls and 47.2% boys. The overall prevalence of low vision was 15.2%. The prevalence of low vision was significantly higher in the age group 6-10 years (17.1%; P=0.05). Low vision was more prevalent among television viewers (17.2%) than in infrequent viewers (14.0%). The proportion of children wearing glasses was higher in frequent internet users and television viewers (21.3%). Also, low vision without aid was higher in frequent viewers. The study findings revealed a greater prevalence of low vision among frequent internet users and television viewers. The proportion of children wearing glasses was higher among frequent viewers. The prevalence of low vision decreased with increasing age.

  4. Rationale for windshield glass system specification requirements for shuttle orbiter

    NASA Technical Reports Server (NTRS)

    Hayashida, K.; King, G. L.; Tesinsiky, J.; Wittenburg, D. R.

    1972-01-01

    A preliminary procurement specification for the space shuttle orbiter windshield pane, and some of the design considerations and rationale leading to its development are presented. The windshield designer is given the necessary methods and procedures for assuring glass pane structural integrity by proof test. These methods and procedures are fully developed for annealed and thermally tempered aluminosilicate, borosilicate, and soda lime glass and for annealed fused silica. Application of the method to chemically tempered glass is considered. Other considerations are vision requirements, protection against bird impact, hail, frost, rain, and meteoroids. The functional requirements of the windshield system during landing, ferrying, boost, space flight, and entry are included.

  5. Effect of Number of Zones on Subjective Vision in Concentric Bifocal Optics.

    PubMed

    Legras, Richard; Rio, David

    2015-11-01

    To evaluate the influence of the number of concentric zones of a center-near bifocal optics on the subjective quality of vision. Twenty-two subjects scored with a five-item continuous grading scale the quality of vision of calculated images (i.e., three high-contrast 20/50 letters) viewed through their best sphero-cylindrical correction and a 3-mm pupil to limit the impact of their aberrations. Through-focus images were calculated from -4 to +2 diopters (D), each 0.25 D, in the presence of center-near bifocal optics (Add 2.5 D) varying by their number of concentric zones (from 2 to 20). To compare the results obtained with these profiles, we calculated the area under the (through-focus) curve (AUC) higher than 2 out of 5 (i.e., limit between a poor and a fair image quality, considered as the limit of acceptability). This value was normalized by the naked eye condition and divided into distance, intermediate, and near AUC. The results showed large interindividual variations. Distance AUC remained quite similar whatever the profile, near AUC decreased with the number of concentric zones, and intermediate AUC rose with the number of concentric zones. With 10 and 20 concentric zones, diffraction phenomenon induced constructive interferences at intermediate proximities and destructive interferences at distance and near proximities. To balance distance, intermediate, and near quality of vision, a number of zones between 8 and 10 should be chosen. If the subject does not need intermediate quality of vision, then a profile with two to five zones should be favored.

  6. Research on detection method of UAV obstruction based on binocular vision

    NASA Astrophysics Data System (ADS)

    Zhu, Xiongwei; Lei, Xusheng; Sui, Zhehao

    2018-04-01

    For the autonomous obstacle positioning and ranging in the process of UAV (unmanned aerial vehicle) flight, a system based on binocular vision is constructed. A three-stage image preprocessing method is proposed to solve the problem of the noise and brightness difference in the actual captured image. The distance of the nearest obstacle is calculated by using the disparity map that generated by binocular vision. Then the contour of the obstacle is extracted by post-processing of the disparity map, and a color-based adaptive parameter adjustment algorithm is designed to extract contours of obstacle automatically. Finally, the safety distance measurement and obstacle positioning during the UAV flight process are achieved. Based on a series of tests, the error of distance measurement can keep within 2.24% of the measuring range from 5 m to 20 m.

  7. Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses

    PubMed Central

    Brezna, Wolfgang; Lux, Kirsten; Dragostinoff, Nikolaus; Krutzler, Christian; Plank, Nicole; Tobisch, Rainer; Boltz, Agnes; Garhöfer, Gerhard; Told, Reinhard; Witkowska, Katarzyna; Schmetterer, Leopold

    2016-01-01

    Purpose The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. Methods The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14–55 cd/m2, mesopic to photopic) were performed at different distances. Results Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001). Conclusions At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype. Translational Relevance The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure. PMID:27777828

  8. Differences in children and adolescents' ability of reporting two CVS-related visual problems.

    PubMed

    Hu, Liang; Yan, Zheng; Ye, Tiantian; Lu, Fan; Xu, Peng; Chen, Hao

    2013-01-01

    The present study examined whether children and adolescents can correctly report dry eyes and blurred distance vision, two visual problems associated with computer vision syndrome. Participants are 913 children and adolescents aged 6-17. They were asked to report their visual problems, including dry eyes and blurred distance vision, and received an eye examination, including tear film break-up time (TFBUT) and visual acuity (VA). Inconsistency was found between participants' reports of dry eyes and TFBUT results among all 913 participants as well as for all of four subgroups. In contrast, consistency was found between participants' reports of blurred distance vision and VA results among 873 participants who had never worn glasses as well as for the four subgroups. It was concluded that children and adolescents are unable to report dry eyes correctly; however, they are able to report blurred distance vision correctly. Three practical implications of the findings were discussed. Little is known about children's ability to report their visual problems, an issue critical to diagnosis and treatment of children's computer vision syndrome. This study compared children's self-reports and clinic examination results and found children can correctly report blurred distance vision but not dry eyes.

  9. Global causes of blindness and distance vision impairment 1990-2020: a systematic review and meta-analysis.

    PubMed

    Flaxman, Seth R; Bourne, Rupert R A; Resnikoff, Serge; Ackland, Peter; Braithwaite, Tasanee; Cicinelli, Maria V; Das, Aditi; Jonas, Jost B; Keeffe, Jill; Kempen, John H; Leasher, Janet; Limburg, Hans; Naidoo, Kovin; Pesudovs, Konrad; Silvester, Alex; Stevens, Gretchen A; Tahhan, Nina; Wong, Tien Y; Taylor, Hugh R

    2017-12-01

    Contemporary data for causes of vision impairment and blindness form an important basis of recommendations in public health policies. Refreshment of the Global Vision Database with recently published data sources permitted modelling of cause of vision loss data from 1990 to 2015, further disaggregation by cause, and forecasts to 2020. In this systematic review and meta-analysis, we analysed published and unpublished population-based data for the causes of vision impairment and blindness from 1980 to 2014. We identified population-based studies published before July 8, 2014, by searching online databases with no language restrictions (MEDLINE from Jan 1, 1946, and Embase from Jan 1, 1974, and the WHO Library Database). We fitted a series of regression models to estimate the proportion of moderate or severe vision impairment (defined as presenting visual acuity of <6/18 but ≥3/60 in the better eye) and blindness (presenting visual acuity of <3/60 in the better eye) by cause, age, region, and year. We identified 288 studies of 3 983 541 participants contributing data from 98 countries. Among the global population with moderate or severe vision impairment in 2015 (216·6 million [80% uncertainty interval 98·5 million to 359·1 million]), the leading causes were uncorrected refractive error (116·3 million [49·4 million to 202·1 million]), cataract (52·6 million [18·2 million to 109·6 million]), age-related macular degeneration (8·4 million [0·9 million to 29·5 million]), glaucoma (4·0 million [0·6 million to 13·3 million]), and diabetic retinopathy (2·6 million [0·2 million to 9·9 million]). Among the global population who were blind in 2015 (36·0 million [12·9 million to 65·4 million]), the leading causes were cataract (12·6 million [3·4 million to 28·7 million]), uncorrected refractive error (7·4 million [2·4 million to 14·8 million]), and glaucoma (2·9 million [0·4 million to 9·9 million]). By 2020, among the global population with

  10. The Effects of Videoconferenced Distance-Learning Instruction in a Taiwanese Company

    ERIC Educational Resources Information Center

    Lin, Chin-Hung; Yang, Shu-Ching

    2011-01-01

    Distance learning, where instruction is given to students despite wide separations of students and teachers, is increasingly popular. Videoconferencing, which is examined in this study, is a distance learning mode of featuring real-time interaction of students and teachers and provides sequence, real-time, vision, and actual interaction. This…

  11. Global cost of correcting vision impairment from uncorrected refractive error.

    PubMed

    Fricke, T R; Holden, B A; Wilson, D A; Schlenther, G; Naidoo, K S; Resnikoff, S; Frick, K D

    2012-10-01

    To estimate the global cost of establishing and operating the educational and refractive care facilities required to provide care to all individuals who currently have vision impairment resulting from uncorrected refractive error (URE). The global cost of correcting URE was estimated using data on the population, the prevalence of URE and the number of existing refractive care practitioners in individual countries, the cost of establishing and operating educational programmes for practitioners and the cost of establishing and operating refractive care facilities. The assumptions made ensured that costs were not underestimated and an upper limit to the costs was derived using the most expensive extreme for each assumption. There were an estimated 158 million cases of distance vision impairment and 544 million cases of near vision impairment caused by URE worldwide in 2007. Approximately 47 000 additional full-time functional clinical refractionists and 18 000 ophthalmic dispensers would be required to provide refractive care services for these individuals. The global cost of educating the additional personnel and of establishing, maintaining and operating the refractive care facilities needed was estimated to be around 20 000 million United States dollars (US$) and the upper-limit cost was US$ 28 000 million. The estimated loss in global gross domestic product due to distance vision impairment caused by URE was US$ 202 000 million annually. The cost of establishing and operating the educational and refractive care facilities required to deal with vision impairment resulting from URE was a small proportion of the global loss in productivity associated with that vision impairment.

  12. Stroboscopic Vision as a Treatment for Space Motion Sickness

    NASA Technical Reports Server (NTRS)

    Reschke, Millard F.; Somers, Jeffrey T.; Ford, George; Krnavek, Jody M.

    2007-01-01

    Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill Jones we have evaluated stroboscopic vision as a method of preventing motion sickness. Given that the data presented by professor Melvill Jones were primarily post hoc results following a study not designed to investigate motion sickness, it is unclear how motion sickness results were actually determined. Building on these original results, we undertook a three part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness using: (1) visual field reversal, (2) Reading while riding in a car (with or without external vision present), and (3) making large pitch head movements during parabolic flight.

  13. Data-Fusion for a Vision-Aided Radiological Detection System: Sensor dependence and Source Tracking

    NASA Astrophysics Data System (ADS)

    Stadnikia, Kelsey; Martin, Allan; Henderson, Kristofer; Koppal, Sanjeev; Enqvist, Andreas

    2018-01-01

    The University of Florida is taking a multidisciplinary approach to fuse the data between 3D vision sensors and radiological sensors in hopes of creating a system capable of not only detecting the presence of a radiological threat, but also tracking it. The key to developing such a vision-aided radiological detection system, lies in the count rate being inversely dependent on the square of the distance. Presented in this paper are the results of the calibration algorithm used to predict the location of the radiological detectors based on 3D distance from the source to the detector (vision data) and the detectors count rate (radiological data). Also presented are the results of two correlation methods used to explore source tracking.

  14. Teaching, Testing, and Evaluating Roger D. Mc Leod's Models for Vision, and its Repair, by Patent-pending Naturoptics.

    NASA Astrophysics Data System (ADS)

    Niemi, Paul R.; D., O.; Mc Leod, David M.; Mc Leod, Roger D.

    2007-04-01

    RDM taught a health professional how to recover her previously impaired near vision in one session, also bringing a similar male from 20/30 to 20/10, distance vision, in about ten minutes; another health professional's improvement went from 20/300 to 20/20 in three sessions. A former athlete achieved a distance improvement from 20/800 to 20/100, again, in three sessions. RDM offers to replicate these types of improvements, using patent-pending Naturoptics under monitored conditions, and non-disclosure restraints, to protect franchising and patent-pending rights. Evening atropine use, controlled, at Singapore's National Eye Center, demonstrated an effect against myopia. Does this actually constitute an experimental verification of Mc Leod's Airy-disk radius-formula explanation of how vision works, and predicts how it can be damaged/repaired? Evaluation and documentation is to be by close and distance vision standard charts, or their equivalents, with guaranteed ``chart'' improvements of one line per session, after the beginning visit, or the session is free. Patent-pending Naturoptics differs from all vision-boosting competitors by safely re-eliciting vision's feedback control self-repairs, including astigmatism and presbyopia. To cite this abstract, use the following reference: http://meetings.aps.org/link/BAPS.2007.NES07.C2.4

  15. Analysis of patients with good uncorrected distance and near vision after monofocal intraocular lens implantation.

    PubMed

    Nanavaty, Mayank A; Vasavada, Abhay R; Patel, Anil S; Raj, Shetal M; Desai, Tejas H

    2006-07-01

    To analyze factors contributing to uncorrected visual acuity of at least 6/12 for distance and at least J4 for near (pseudoaccommodation) after monofocal intraocular lens (IOL) implantation. Iladevi Cataract and IOL Research Center, Ahmedabad, India. In a case-controlled study of 30 eyes (30 patients) that had phacoemulsification, those with pseudoaccommodation were assigned to cases and 30 eyes (30 patients) without pseudoaccommodation were designated as controls. Controls were matched by identical best corrected visual acuity, age, and postoperative duration. Subjective refraction was done with retinoscopy. Factors analyzed included corneal astigmatism, pupil size, axial IOL movement, amplitude of accommodation, axial length (AL), and age. Corneal astigmatism was noted on topography and interpreted as against the rule (ATR) (180 +/- 15 degrees), with the rule (WTR) (90 +/- 15 degrees), and oblique (OB) (45/135 +/- 30 degrees). Pupil size was noted on topographic display and AL and anterior chamber depth (ACD) on immersion A-scan. The axial IOL movement was calculated as the difference in ACD after instillation of cyclopentolate 1% (Cyclopent) and subsequently pilocarpine nitrate 2% (Carpinol) at separate visits, and amplitude of accommodation was measured with static and dynamic retinoscopy. Multivariate logistic regression and odds ratio with 95% confidence intervals were determined. Mean spherical equivalent was -0.45 +/- 0.63 diopter (D) in cases and -0.35 +/- 0.83 D (P = .61) in controls. Multivariate logistic regression in cases versus controls: corneal astigmatism (ATR versus WTR and OB collectively): 10.19 [1.8,57.44], P = .009; pupil size: 0.45 [0.07,2.71], P = .38; axial IOL movement: 1.39 [0.51,0.77], P = .514; amplitude of accommodation: 2.95 [0.93,9.3], P = .065; AL: 0.55 [0.29,1.02], P = .058; and age: 0.98 [0.5,1.95], P = .963. The study suggests a significant role of ATR corneal astigmatism in good uncorrected distance and near vision after

  16. Reduced vision selectively impairs spatial updating in fall-prone older adults.

    PubMed

    Barrett, Maeve M; Doheny, Emer P; Setti, Annalisa; Maguinness, Corrina; Foran, Timothy G; Kenny, Rose Anne; Newell, Fiona N

    2013-01-01

    The current study examined the role of vision in spatial updating and its potential contribution to an increased risk of falls in older adults. Spatial updating was assessed using a path integration task in fall-prone and healthy older adults. Specifically, participants conducted a triangle completion task in which they were guided along two sides of a triangular route and were then required to return, unguided, to the starting point. During the task, participants could either clearly view their surroundings (full vision) or visuo-spatial information was reduced by means of translucent goggles (reduced vision). Path integration performance was measured by calculating the distance and angular deviation from the participant's return point relative to the starting point. Gait parameters for the unguided walk were also recorded. We found equivalent performance across groups on all measures in the full vision condition. In contrast, in the reduced vision condition, where participants had to rely on interoceptive cues to spatially update their position, fall-prone older adults made significantly larger distance errors relative to healthy older adults. However, there were no other performance differences between fall-prone and healthy older adults. These findings suggest that fall-prone older adults, compared to healthy older adults, have greater difficulty in reweighting other sensory cues for spatial updating when visual information is unreliable.

  17. Stroboscopic Vision as a Treatment Motion Sickness

    NASA Technical Reports Server (NTRS)

    Reschke, Millard F.; Somers, J. T.; Ford, G.; Krnavek, J. M.; Hwang, E. y.; Kornilova, L. N.; Leigh, R. J.

    2006-01-01

    Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill-Jones, we have evaluated stroboscopic vision as a method of preventing motion sickness. Methods: Nineteen subjects read text while making +/-20deg head movements in the horizontal plane at 0.2 Hz while wearing left-right reversing prisms during exposure to 4 Hz stroboscopic or normal room illumination. Testing was repeated using LCD shutter glasses as the stroboscopic source with an additional 19 subjects. Results: With Strobe, motion sickness was significantly lower than with normal room illumination. Results with the LCD shutter glasses were analogous to those observed with environmental strobe. Conclusions: Stroboscopic illumination appears to be effective where retinal slip is a factor in eliciting motion sickness. Additional research is evaluating the glasses efficacy for, carsickness, sickness in parabolic flight and seasickness. There is evidence from pilot studies showing that the glasses reduce saccade velocity to visually presented targets by approximately half of the normal values. It is interesting to note that adaptation to space flight may also slow saccade velocity.

  18. Indoor Spatial Updating With Impaired Vision

    PubMed Central

    Legge, Gordon E.; Granquist, Christina; Baek, Yihwa; Gage, Rachel

    2016-01-01

    Purpose Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Methods Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. Results The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. Conclusions People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient. PMID:27978556

  19. Indoor Spatial Updating With Impaired Vision.

    PubMed

    Legge, Gordon E; Granquist, Christina; Baek, Yihwa; Gage, Rachel

    2016-12-01

    Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient.

  20. [Ophthalmologist and "computer vision syndrome"].

    PubMed

    Barar, A; Apatachioaie, Ioana Daniela; Apatachioaie, C; Marceanu-Brasov, L

    2007-01-01

    The authors had tried to collect the data available on the Internet about a subject that we consider as being totally ignored in the Romanian scientific literature and unexpectedly insufficiently treated in the specialized ophthalmologic literature. Known in the specialty literature under the generic name of "Computer vision syndrome", it is defined by the American Optometric Association as a complex of eye and vision problems related to the activities which stress the near vision and which are experienced in relation, or during, the use of the computer. During the consultations we hear frequent complaints of eye-strain - asthenopia, headaches, blurred distance and/or near vision, dry and irritated eyes, slow refocusing, neck and backache, photophobia, sensation of diplopia, light sensitivity, and double vision, but because of the lack of information, we overlooked them too easily, without going thoroughly into the real motives. In most of the developed countries, there are recommendations issued by renowned medical associations with regard to the definition, the diagnosis, and the methods for the prevention, treatment and periodical control of the symptoms found in computer users, in conjunction with an extremely detailed ergonomic legislation. We found out that these problems incite a much too low interest in our country. We would like to rouse the interest of our ophthalmologist colleagues in the understanding and the recognition of these symptoms and in their treatment, or at least their improvement, through specialized measures or through the cooperation with our specialist occupational medicine colleagues.

  1. A compact high power Er:Yb:glass eyesafe laser for infrared remote sensing applications

    NASA Astrophysics Data System (ADS)

    Vitiello, Marco; Pizzarulli, Andrea; Ruffini, Andrea

    2010-10-01

    The key features and performances of a compact, lightweight, high power Er3+:Yb3+ glass laser transmitter are reported on. The theory employed to get an optimal design of the device is also described. In free running regime high energies of about 15mJ in 3ms long pulses were obtained, with an optical efficiency close to 85%. When q-switched by a Co: MALO crystal of carefully selected initial transmittivity, a high peak power in excess of 500 kW was obtained in about 9ns pulse duration, with an optical efficiency of 60%. The laser was successfully run with no significant power losses at repetition rates up to 5Hz due to a carefully designed heat sink which allowed an efficient conduction cooling of both the diode bars and the phosphate glass. The transmitter emits at a wavelength of 1535nm in the so-called "eyesafe" region of the light spectrum thus being highly attractive for any application involving the risk of human injury as is typically the case in remote sensing activities. Moreover, the spectral band around 1,5mm corresponds to a peak in the athmospheric transmittance thus being more effective in adverse weather conditions with respect to other wavelengths. Actually, the device has been successfully integrated into a rangefinder system allowing a reliable and precise detection of small targets at distances up to 20Km. Moreover, the transmitter capabilities were used into a state of the art infrared laser illuminator for night vision allowing even the recognition of a human being at distances in excess of 5Km.

  2. Vision of low astigmats through thick and thin lathe-cut soft contact lenses.

    PubMed

    Cho, P; Woo, G C

    2001-01-01

    Distance and near visual acuity of 13 low astigmats were determined in a double-masked experiment through thick and thin (centre thickness 0.12 mm and 0.06 mm, respectively) spherical lathe-cut soft lenses. For each lens type, distance and near LogMAR VA and over-refraction were assessed with different logMAR VA charts. For 70% of the subjects, the residual astigmatism was significantly lower than the refractive astigmatism with thicker lenses. No statistically significant differences in the distance and near logMAR VA was found between the two lens types using any of the charts used, though, in general, logMAR VA obtained through the thicker lens was better than logMAR VA through the thinner lens. The variabilities in distance and near logMAR VA between the two lens types increased with decreased contrast. The variabilities in distance logMAR VA were greater with Chinese charts than with English charts, and LogMAR VA with Chinese charts were significantly worse for both lens types. Based on the results of this study, we concluded that thicker spherical lathe-cut soft lenses provide better vision in low astigmats. The Snellen acuity test is inadequate for vision assessment of soft contact lens wearers. When a patient wearing thin soft contact lenses complains of poor vision in spite of 6/6 or 6/5 Snellen acuity, changing to thicker lenses may be considered.

  3. Vision Impairment and Ocular Morbidity in a Refugee Population in Malawi.

    PubMed

    Kaphle, Dinesh; Gyawali, Rajendra; Kandel, Himal; Reading, Angela; Msosa, Joseph Matiya

    2016-02-01

    To provide screening services and obtain information on the eye health status and distribution of visual impairments in a refugee population of the sole refugee camp in Malawi. A general eye screening at Dzaleka refugee settlement camp was organized in November 2012. Final-year optometry students conducted detailed optometry examinations, including visual acuity (VA) assessment for near and distance, retinoscopy, and subjective refraction in cases with distance VA less than 6/12 or near VA less than N8, anterior and posterior segment evaluation. Their findings were then verified by an optometrist. The World Health Organization definition of vision impairment was followed, and the cause of vision impairment was determined at the end of each examination. Where possible, participants requiring refractive correction were provided spectacles free of cost. Of a total 635 participants examined, around one-half were male with 61% in the 16 to 49 years age group. The overall prevalence of presenting blindness, severe vision impairment, and vision impairment were 1.3% (95% confidence interval [95% CI], 0.5 to 2.4), 0.5% (95% CI, 0.0 to 1.1), and 3.6% (95% CI, 2.3 to 5.2), respectively. Overall vision impairment (VA <6/18) was present in 5.4% (95% CI, 3.6 to 7.1) of the participants. The principal causes of blindness, severe vision impairment, and vision impairment were cataracts, refractive errors, and corneal opacities, respectively; and more than 90% of the overall vision impairment was avoidable. Refractive errors and presbyopia were the most common morbidity, present in more than two-thirds of the participants examined. Only 5% of all the participants ever had a previous eye examination. The prevalence and causes of blindness and vision impairment in a refugee population are comparable with those of the general population. Lack of basic eye care services in the health center for refugees is a major concern. The health care facility in the settlement camp needs to be

  4. Thermal property of holmium doped lithium lead borate glasses

    NASA Astrophysics Data System (ADS)

    Usharani, V. L.; Eraiah, B.

    2018-04-01

    The new glass system of holmium doped lithium lead borate glasses were prepared by conventional melt quenching technique. The thermal stability of the different compositions of Ho3+ ions doped lithium lead borate glasses were studied by using TG-DTA. The Tg values are ranging from 439 to 444 °C with respect to the holmium concentration. Physical parameters like polaron radius(rp), inter-nuclear distance (ri), field strength (F) and polarizability (αm) of oxide ions were calculated using appropriate formulae.

  5. Clipping polygon faces through a polyhedron of vision

    NASA Technical Reports Server (NTRS)

    Florence, Judit K. (Inventor); Rohner, Michel A. (Inventor)

    1980-01-01

    A flight simulator combines flight data and polygon face terrain data to provide a CRT display at each window of the simulated aircraft. The data base specifies the relative position of each vertex of each polygon face therein. Only those terrain faces currently appearing within the pyramid of vision defined by the pilots eye and the edges of the pilots window need be displayed at any given time. As the orientation of the pyramid of vision changes in response to flight data, the displayed faces are correspondingly displaced, eventually moving out of the pyramid of vision. Faces which are currently not visible (outside the pyramid of vision) are clipped from the data flow. In addition, faces which are only partially outside of pyramid of vision are reconstructed to eliminate the outside portion. Window coordinates are generated defining the distance between each vertex and each of the boundary planes forming the pyramid of vision. The sign bit of each window coordinate indicates whether the vertex is on the pyramid of vision side of the associated boundary panel (positive), or on the other side thereof (negative). The set of sign bits accompanying each vertex constitute the outcode of that vertex. The outcodes (O.C.) are systematically processed and examined to determine which faces are completely inside the pyramid of vision (Case A--all signs positive), which faces are completely outside (Case C--All signs negative) and which faces must be reconstructed (Case B--both positive and negative signs).

  6. Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enqvist, Andreas; Koppal, Sanjeev; Riley, Phillip

    2015-07-01

    Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological datamore » can be incorporated by means of data fusion of the two sensors' output data. (authors)« less

  7. Binocular Vision in Chronic Fatigue Syndrome.

    PubMed

    Godts, Daisy; Moorkens, Greta; Mathysen, Danny G P

    2016-01-01

    To compare binocular vision measurements between Chronic Fatigue Syndrome (CFS) patients and healthy controls. Forty-one CFS patients referred by the Reference Centre for Chronic Fatigue Syndrome of the Antwerp University Hospital and forty-one healthy volunteers, matched for age and gender, underwent a complete orthoptic examination. Data of visual acuity, eye position, fusion amplitude, stereopsis, ocular motility, convergence, and accommodation were compared between both groups. Patients with CFS showed highly significant smaller fusion amplitudes (P < 0.001), reduced convergence capacity (P < 0.001), and a smaller accommodation range (P < 0.001) compared to the control group. In patients with CFS binocular vision, convergence and accommodation should be routinely examined. CFS patients will benefit from reading glasses either with or without prism correction in an earlier stage compared to their healthy peers. Convergence exercises may be beneficial for CFS patients, despite the fact that they might be very tiring. Further research will be necessary to draw conclusions about the efficacy of treatment, especially regarding convergence exercises. To our knowledge, this is the first prospective study evaluating binocular vision in CFS patients. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.

  8. Neural architectures for stereo vision.

    PubMed

    Parker, Andrew J; Smith, Jackson E T; Krug, Kristine

    2016-06-19

    Stereoscopic vision delivers a sense of depth based on binocular information but additionally acts as a mechanism for achieving correspondence between patterns arriving at the left and right eyes. We analyse quantitatively the cortical architecture for stereoscopic vision in two areas of macaque visual cortex. For primary visual cortex V1, the result is consistent with a module that is isotropic in cortical space with a diameter of at least 3 mm in surface extent. This implies that the module for stereo is larger than the repeat distance between ocular dominance columns in V1. By contrast, in the extrastriate cortical area V5/MT, which has a specialized architecture for stereo depth, the module for representation of stereo is about 1 mm in surface extent, so the representation of stereo in V5/MT is more compressed than V1 in terms of neural wiring of the neocortex. The surface extent estimated for stereo in V5/MT is consistent with measurements of its specialized domains for binocular disparity. Within V1, we suggest that long-range horizontal, anatomical connections form functional modules that serve both binocular and monocular pattern recognition: this common function may explain the distortion and disruption of monocular pattern vision observed in amblyopia.This article is part of the themed issue 'Vision in our three-dimensional world'. © 2016 The Authors.

  9. Enhanced Monocular Visual Odometry Integrated with Laser Distance Meter for Astronaut Navigation

    PubMed Central

    Wu, Kai; Di, Kaichang; Sun, Xun; Wan, Wenhui; Liu, Zhaoqin

    2014-01-01

    Visual odometry provides astronauts with accurate knowledge of their position and orientation. Wearable astronaut navigation systems should be simple and compact. Therefore, monocular vision methods are preferred over stereo vision systems, commonly used in mobile robots. However, the projective nature of monocular visual odometry causes a scale ambiguity problem. In this paper, we focus on the integration of a monocular camera with a laser distance meter to solve this problem. The most remarkable advantage of the system is its ability to recover a global trajectory for monocular image sequences by incorporating direct distance measurements. First, we propose a robust and easy-to-use extrinsic calibration method between camera and laser distance meter. Second, we present a navigation scheme that fuses distance measurements with monocular sequences to correct the scale drift. In particular, we explain in detail how to match the projection of the invisible laser pointer on other frames. Our proposed integration architecture is examined using a live dataset collected in a simulated lunar surface environment. The experimental results demonstrate the feasibility and effectiveness of the proposed method. PMID:24618780

  10. Visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens: A prospective study

    PubMed Central

    Sachdev, Gitansha Shreyas; Ramamurthy, Shreyas; Sharma, Umesh; Dandapani, Ramamurthy

    2018-01-01

    Purpose: The aim of this study was to analyze the objective and subjective visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens (EROV IOL), the Tecnis Symfony. Methods: This was a prospective interventional case series conducted at a tertiary eye care hospital in South India. The study included patients with bilateral implantation of EROV IOLs. The uncorrected and corrected visual acuity for distance, intermediate, and near vision was recorded at 6 weeks and 6 months’ postoperative visit. A subjective questionnaire was administered to assess spectacle independence, photic phenomenon, and overall satisfaction. All data were recorded using Microsoft Excel worksheet. The analyses were performed using SPSS for windows software. Results: Our study included fifty patients with bilateral implantation of EROV IOLs. The mean age was 59.84 ± 11.68 years. The mean uncorrected binocular distance, intermediate, and near visual acuity (in standard decimal equivalent) was 0.89,0.99 and 0.99 respectively, at 6 months’ postoperative visit. Ninety-six percent of the patients did not require spectacles for distance and 98% of the patients were free from spectacles for intermediate and near vision. 94% of our patients perceived no or minimal photic phenomena such as glare and halos. The mean subjective patient satisfaction score (out of 10) for distance, intermediate, and near was 9, 10, and 9, respectively. Conclusion: The EROV IOLs demonstrated high levels of spectacle independence for distance, intermediate, and near vision. The incidence of photic phenomena observed was minimal with a high level of patient satisfaction. PMID:29480252

  11. Oculocutaneous albinism: identifying and overcoming barriers to vision care in a Nigerian population.

    PubMed

    Udeh, N N; Eze, B I; Onwubiko, S N; Arinze, O C; Onwasigwe, E N; Umeh, R E

    2014-06-01

    To assess eye care service utilization, and identify access barriers in a south-eastern Nigerian albino population. The study was a population-based, cross-sectional survey conducted in Enugu state between August, 2011 and January, 2012. Using the data base of the state's Albino Foundation and tailored awareness creation, persons living with albinism were identified and recruited at two study centres. Data on participants' socio-demographics, perception of vision, visual needs, previous eye examination and or low vision assessment, use of glasses or low vision devices were collected. Reasons for non-utilisation of available vision care services were also obtained. Descriptive and comparative statistics were performed. A p < 0.05 was considered statistically significant. The participants (n = 153; males 70; females 83; sex ratio: 1:1.1) were aged 23.46 + 10.44 SD years (range 6-60 years). Most--95.4 % of the participants had no previous low vision assessment and none--0.0% had used low vision device. Of the participants, 82.4% reported previous eye examination, 33.3% had not used spectacles previously, despite the existing need. Ignorance--88.9% and poor access--8.5% were the main barriers to uptake of vision care services. In Enugu, Nigeria, there is poor awareness and low utilization of vision care services among people with albinism. The identified barriers to vision care access are amenable to awareness creation and logistic change in the provision of appropriate vision care services.

  12. Clinical characteristics and causes of visual impairment in a low vision clinic in northern Jordan.

    PubMed

    Bakkar, May M; Alzghoul, Eman A; Haddad, Mera F

    2018-01-01

    The aim of the study was to identify causes of visual impairment among patients attending a low vision clinic in the north of Jordan and to study the relevant demographic characteristics of these patients. The retrospective study was conducted through a review of clinical records of 135 patients who attended a low vision clinic in Irbid. Clinical characteristics of the patients were collected, including age, gender, primary cause of low vision, best corrected visual acuity, and current prescribed low vision aids. Descriptive statistics analysis using numbers and percentages were calculated to summarize categorical and nominal data. A total of 135 patients (61 [45.2%] females and 74 [54.8%] males) were recruited in the study. Mean age ± standard deviation for the study population was 24.53 ± 16.245 years; age range was 5-90 years. Of the study population, 26 patients (19.3%) had mild visual impairment, 61 patients (45.2%) had moderate visual impairment, 27 patients (20.0%) had severe visual impairment, and 21 patients (15.6%) were blind. The leading causes of visual impairment across all age groups were albinism (31.9%) and retinitis pigmentosa (RP) (18.5%). Albinism also accounted for the leading cause of visual impairment among the pediatric age group (0-15 years) while albinism, RP, and keratoconus were the primary causes of visual impairment for older patients. A total of 59 patients (43.7%) were given low vision aids either for near or distance. The only prescribed low vision aids for distances were telescopes. For near, spectacle-type low vision aid was the most commonly prescribed low vision aids. Low vision services in Jordan are still very limited. A national strategy programme to increase awareness of low vision services should be implemented, and health care policies should be enforced to cover low vision aids through the national medical insurance.

  13. [Optical Care in Low Vision Patients].

    PubMed

    von Livonius, Bettina

    2018-05-17

    The numbers of low vision patients will steadily increase because of increasing longevity. It is important to be aware of those patients so that visual rehabilitation can be started as soon as possible and needed. Before the adjustment of low vision devices a diagnosis should be confirmed in order to check any therapeutic option and to ensure the best individual rehabilitation. If there is no further therapeutic option left a detailed anamnesis of the problems due to low vision should be made to ensure that every patient gets the optical or electronic device he really needs in his everyday life. The first step of the adjustment is to get the best subjective refraction for the far distance and the magnification needed for reading. Thereafter, the testing of different devices can start. It is important to know the advantages and disadvantages of the different devices. Besides the optical devices a counceling of the best light and of edge filters should be made. For the prescription of the devices certain criteria must be performed. That way it is possible to reach the main target namely to improve the quality of life of our low vision patients. Georg Thieme Verlag KG Stuttgart · New York.

  14. Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience.

    PubMed

    Nekolova, Jana; Rozsival, Pavel; Sin, Martin; Jiraskova, Nada

    2017-06-01

    To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.

  15. Vision screening of older drivers for preventing road traffic injuries and fatalities.

    PubMed

    Desapriya, Ediriweera; Harjee, Rahana; Brubacher, Jeffrey; Chan, Herbert; Hewapathirane, D Sesath; Subzwari, Sayed; Pike, Ian

    2014-02-21

    Demographic data in North America, Europe, Asia, Australia and New Zealand suggest a rapid growth in the number of persons over the age of 65 years as the baby boomer generation passes retirement age. As older adults make up an increasing proportion of the population, they are an important consideration when designing future evidence-based traffic safety policies, particularly those that lead to restrictions or cessation of driving. Research has shown that cessation of driving among older drivers can lead to negative emotional consequences such as depression and loss of independence. Older adults who continue to drive tend to do so less frequently than other demographic groups and are more likely to be involved in a road traffic crash, possibly due to what is termed the "low mileage bias". Available research suggests that older driver crash risk estimates based on traditional exposure measures are prone to bias. When annual driving distances are taken in to consideration, older drivers with low driving distances have an increased crash risk, while those with average or high driving distances tend to be safer drivers when compared to other age groups. In addition, older drivers with lower distance driving tend to drive in urban areas which, due to more complex and demanding traffic patterns, tend to be more accident-prone. Failure to control for actual annual driving distances and driving locations among older drivers is referred to as "low mileage bias" in older driver mobility research. It is also important to note that older drivers are more vulnerable to serious injury and death in the event of a traffic crash due to changes in physiology associated with normal ageing. Vision, cognition, and motor functions or skills (e.g., strength, co-ordination, and flexibility) are three key domains required for safe driving. To drive safely, an individual needs to be able to see road signs, road side objects, traffic lights, roadway markings, other vulnerable road users

  16. Three-dimensional ocular kinematics underlying binocular single vision

    PubMed Central

    Misslisch, H.

    2016-01-01

    We have analyzed the binocular coordination of the eyes during far-to-near refixation saccades based on the evaluation of distance ratios and angular directions of the projected target images relative to the eyes' rotation centers. By defining the geometric point of binocular single vision, called Helmholtz point, we found that disparities during fixations of targets at near distances were limited in the subject's three-dimensional visual field to the vertical and forward directions. These disparities collapsed to simple vertical disparities in the projective binocular image plane. Subjects were able to perfectly fuse the vertically disparate target images with respect to the projected Helmholtz point of single binocular vision, independent of the particular location relative to the horizontal plane of regard. Target image fusion was achieved by binocular torsion combined with corrective modulations of the differential half-vergence angles of the eyes in the horizontal plane. Our findings support the notion that oculomotor control combines vergence in the horizontal plane of regard with active torsion in the frontal plane to achieve fusion of the dichoptic binocular target images. PMID:27655969

  17. Perspective Space as a Model for Distance and Size Perception.

    PubMed

    Erkelens, Casper J

    2017-01-01

    In the literature, perspective space has been introduced as a model of visual space. Perspective space is grounded on the perspective nature of visual space during both binocular and monocular vision. A single parameter, that is, the distance of the vanishing point, transforms the geometry of physical space into that of perspective space. The perspective-space model predicts perceived angles, distances, and sizes. The model is compared with other models for distance and size perception. Perspective space predicts that perceived distance and size as a function of physical distance are described by hyperbolic functions. Alternatively, power functions have been widely used to describe perceived distance and size. Comparison of power and hyperbolic functions shows that both functions are equivalent within the range of distances that have been judged in experiments. Two models describing perceived distance on the ground plane appear to be equivalent with the perspective-space model too. The conclusion is that perspective space unifies a number of models of distance and size perception.

  18. Perspective Space as a Model for Distance and Size Perception

    PubMed Central

    2017-01-01

    In the literature, perspective space has been introduced as a model of visual space. Perspective space is grounded on the perspective nature of visual space during both binocular and monocular vision. A single parameter, that is, the distance of the vanishing point, transforms the geometry of physical space into that of perspective space. The perspective-space model predicts perceived angles, distances, and sizes. The model is compared with other models for distance and size perception. Perspective space predicts that perceived distance and size as a function of physical distance are described by hyperbolic functions. Alternatively, power functions have been widely used to describe perceived distance and size. Comparison of power and hyperbolic functions shows that both functions are equivalent within the range of distances that have been judged in experiments. Two models describing perceived distance on the ground plane appear to be equivalent with the perspective-space model too. The conclusion is that perspective space unifies a number of models of distance and size perception. PMID:29225765

  19. The study of stereo vision technique for the autonomous vehicle

    NASA Astrophysics Data System (ADS)

    Li, Pei; Wang, Xi; Wang, Jiang-feng

    2015-08-01

    The stereo vision technology by two or more cameras could recovery 3D information of the field of view. This technology can effectively help the autonomous navigation system of unmanned vehicle to judge the pavement conditions within the field of view, and to measure the obstacles on the road. In this paper, the stereo vision technology in measuring the avoidance of the autonomous vehicle is studied and the key techniques are analyzed and discussed. The system hardware of the system is built and the software is debugged, and finally the measurement effect is explained by the measured data. Experiments show that the 3D reconstruction, within the field of view, can be rebuilt by the stereo vision technology effectively, and provide the basis for pavement condition judgment. Compared with unmanned vehicle navigation radar used in measuring system, the stereo vision system has the advantages of low cost, distance and so on, it has a good application prospect.

  20. Magnitude, temporal trends, and projections of the global prevalence of blindness and distance and near vision impairment: a systematic review and meta-analysis.

    PubMed

    Bourne, Rupert R A; Flaxman, Seth R; Braithwaite, Tasanee; Cicinelli, Maria V; Das, Aditi; Jonas, Jost B; Keeffe, Jill; Kempen, John H; Leasher, Janet; Limburg, Hans; Naidoo, Kovin; Pesudovs, Konrad; Resnikoff, Serge; Silvester, Alex; Stevens, Gretchen A; Tahhan, Nina; Wong, Tien Y; Taylor, Hugh R

    2017-09-01

    Global and regional prevalence estimates for blindness and vision impairment are important for the development of public health policies. We aimed to provide global estimates, trends, and projections of global blindness and vision impairment. We did a systematic review and meta-analysis of population-based datasets relevant to global vision impairment and blindness that were published between 1980 and 2015. We fitted hierarchical models to estimate the prevalence (by age, country, and sex), in 2015, of mild visual impairment (presenting visual acuity worse than 6/12 to 6/18 inclusive), moderate to severe visual impairment (presenting visual acuity worse than 6/18 to 3/60 inclusive), blindness (presenting visual acuity worse than 3/60), and functional presbyopia (defined as presenting near vision worse than N6 or N8 at 40 cm when best-corrected distance visual acuity was better than 6/12). Globally, of the 7·33 billion people alive in 2015, an estimated 36·0 million (80% uncertainty interval [UI] 12·9-65·4) were blind (crude prevalence 0·48%; 80% UI 0·17-0·87; 56% female), 216·6 million (80% UI 98·5-359·1) people had moderate to severe visual impairment (2·95%, 80% UI 1·34-4·89; 55% female), and 188·5 million (80% UI 64·5-350·2) had mild visual impairment (2·57%, 80% UI 0·88-4·77; 54% female). Functional presbyopia affected an estimated 1094·7 million (80% UI 581·1-1686·5) people aged 35 years and older, with 666·7 million (80% UI 364·9-997·6) being aged 50 years or older. The estimated number of blind people increased by 17·6%, from 30·6 million (80% UI 9·9-57·3) in 1990 to 36·0 million (80% UI 12·9-65·4) in 2015. This change was attributable to three factors, namely an increase because of population growth (38·4%), population ageing after accounting for population growth (34·6%), and reduction in age-specific prevalence (-36·7%). The number of people with moderate and severe visual impairment also increased, from 159·9 million

  1. Vision improvement in pilots with presbyopia following perceptual learning.

    PubMed

    Sterkin, Anna; Levy, Yuval; Pokroy, Russell; Lev, Maria; Levian, Liora; Doron, Ravid; Yehezkel, Oren; Fried, Moshe; Frenkel-Nir, Yael; Gordon, Barak; Polat, Uri

    2017-11-24

    Israeli Air Force (IAF) pilots continue flying combat missions after the symptoms of natural near-vision deterioration, termed presbyopia, begin to be noticeable. Because modern pilots rely on the displays of the aircraft control and performance instruments, near visual acuity (VA) is essential in the cockpit. We aimed to apply a method previously shown to improve visual performance of presbyopes, and test whether presbyopic IAF pilots can overcome the limitation imposed by presbyopia. Participants were selected by the IAF aeromedical unit as having at least initial presbyopia and trained using a structured personalized perceptual learning method (GlassesOff application), based on detecting briefly presented low-contrast Gabor stimuli, under the conditions of spatial and temporal constraints, from a distance of 40 cm. Our results show that despite their initial visual advantage over age-matched peers, training resulted in robust improvements in various basic visual functions, including static and temporal VA, stereoacuity, spatial crowding, contrast sensitivity and contrast discrimination. Moreover, improvements generalized to higher-level tasks, such as sentence reading and aerial photography interpretation (specifically designed to reflect IAF pilots' expertise in analyzing noisy low-contrast input). In concert with earlier suggestions, gains in visual processing speed are plausible to account, at least partially, for the observed training-induced improvements. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Causes of visual impairment in children with low vision.

    PubMed

    Shah, Mufarriq; Khan, Mirzaman; Khan, Muhammad Tariq; Khan, Mohammad Younas; Saeed, Nasir

    2011-02-01

    To determine the main causes of visual impairment in children with low vision. To assess the need of spectacles and low vision devices (LVDs) in children and to evaluate visual outcome after using their LVDs for far and near distance. Observational study. Khyber Institute of Ophthalmic Medical Sciences, Peshawar, Pakistan, from June 2006 to December 2007. The clinical record of 270 children with low vision age 4-16 years attending the Low Vision Clinic were included. All those children, aged 4-16 years, who had corrected visual acuity (VA) less than 6/18 in the better eye after medical or surgical treatment, were included in the study. WHO low vision criteria were used to classify into visually impaired, severe visually impaired and blind. Results were described as percentage frequencies. One hundred and eighty nine (70%) were males and 81 (30%) were females. The male to female ratio was 2.3:1. The main causes of visual impairment included nystagmus (15%), Stargardt's disease (14%), maculopathies (13%), myopic macular degeneration (11%) and oculocutaneous albinism (7%). The percentages of visually impaired, severe visually impaired and blind were 33.8%, 27.2% and 39.0% respectively. Spectacles were prescribed to 146 patients and telescopes were prescribed to 75 patients. Spectacles and telescope both were prescribed to 179 patients while Ocutech telescope was prescribed to 4 patients. Retinal diseases nystagmus and macular conditions were mainly responsible for low vision in children. Visually impaired children especially with hereditary/congenital ocular anomalies benefit from refraction and low vision services which facilitate vision enhancement and inclusive education.

  3. Clinical characteristics and causes of visual impairment in a low vision clinic in northern Jordan

    PubMed Central

    Bakkar, May M; Alzghoul, Eman A; Haddad, Mera F

    2018-01-01

    Aim The aim of the study was to identify causes of visual impairment among patients attending a low vision clinic in the north of Jordan and to study the relevant demographic characteristics of these patients. Subjects and methods The retrospective study was conducted through a review of clinical records of 135 patients who attended a low vision clinic in Irbid. Clinical characteristics of the patients were collected, including age, gender, primary cause of low vision, best corrected visual acuity, and current prescribed low vision aids. Descriptive statistics analysis using numbers and percentages were calculated to summarize categorical and nominal data. Results A total of 135 patients (61 [45.2%] females and 74 [54.8%] males) were recruited in the study. Mean age ± standard deviation for the study population was 24.53 ± 16.245 years; age range was 5–90 years. Of the study population, 26 patients (19.3%) had mild visual impairment, 61 patients (45.2%) had moderate visual impairment, 27 patients (20.0%) had severe visual impairment, and 21 patients (15.6%) were blind. The leading causes of visual impairment across all age groups were albinism (31.9%) and retinitis pigmentosa (RP) (18.5%). Albinism also accounted for the leading cause of visual impairment among the pediatric age group (0–15 years) while albinism, RP, and keratoconus were the primary causes of visual impairment for older patients. A total of 59 patients (43.7%) were given low vision aids either for near or distance. The only prescribed low vision aids for distances were telescopes. For near, spectacle-type low vision aid was the most commonly prescribed low vision aids. Conclusion Low vision services in Jordan are still very limited. A national strategy programme to increase awareness of low vision services should be implemented, and health care policies should be enforced to cover low vision aids through the national medical insurance. PMID:29662299

  4. Smartphone serious games for vision and hearing assessment.

    PubMed

    Dias, Pedro; Aguiar, Bruno; Sousa, Filipe; Sousa, Augusto

    2015-01-01

    Falls are the second leading cause of accidental injury deaths worldwide. In this paper, it is intended to define methodologies that permit the evaluation of two potential factors which might have an impact on fall risk, these are: visual and hearing loss. The aim of the work developed is not to replace clinic visits, but to offer the user the means to continue the tracking of his vision and hearing at home, during the long time intervals between clinical tests. Tests conducted in a sample of our target users indicate a good ability to measure vision and hearing using an android smartphone and the proposed methodologies. While some tests require further validation, promising results were achieved in the most common tests for vision and hearing, presenting a good correlation between the system's results when compared to the traditional tests (for distance visual acuity) and the data gathered from the users (for hearing tests).

  5. Vision rehabilitation interventions following mild traumatic brain injury: a scoping review.

    PubMed

    Simpson-Jones, Mary E; Hunt, Anne W

    2018-04-10

    To broadly examine the literature to identify vision interventions following mild traumatic brain injury. Objectives are to identify: (1) evidence-informed interventions for individuals with visual dysfunction after mild traumatic brain injury; (2) professions providing these interventions; (3) gaps in the literature and areas for further research. A scoping review was conducted of four electronic databases of peer-reviewed literature from the databases earliest records to June 2017. Articles were included if the study population was mild traumatic brain injury/concussion and a vision rehabilitation intervention was tested. Two independent reviewers screened articles for inclusion, extracted data, and identified themes. The initial search identified 3111 records. Following exclusions, 22 articles were included in the final review. Nine studies evaluated optical devices, such as corrective spectacles, contact lenses, prisms, or binasal occlusion. Two studies assessed vision therapy. Ten studies examined vision therapy using optical devices. One study investigated hyperbaric oxygen therapy. Optometrists performed these interventions in most of the studies. Future research should address quality appraisal of this literature, interventions that include older adult and pediatric populations, and interdisciplinary interventions. There are promising interventions for vision deficits following mild traumatic brain injury. However, there are multiple gaps in the literature that should be addressed by future research. Implications for Rehabilitation Mild traumatic brain injury may result in visual deficits that can contribute to poor concentration, headaches, fatigue, problems reading, difficulties engaging in meaningful daily activities, and overall reduced quality of life. Promising interventions for vision rehabilitation following mild traumatic brain injury include the use of optical devices (e.g., prism glasses), vision or oculomotor therapy (e.g., targeted exercises to

  6. Night vision: requirements and possible roadmap for FIR and NIR systems

    NASA Astrophysics Data System (ADS)

    Källhammer, Jan-Erik

    2006-04-01

    A night vision system must increase visibility in situations where only low beam headlights can be used today. As pedestrians and animals have the highest risk increase in night time traffic due to darkness, the ability of detecting those objects should be the main performance criteria, and the system must remain effective when facing the headlights of oncoming vehicles. Far infrared system has been shown to be superior to near infrared system in terms of pedestrian detection distance. Near infrared images were rated to have significantly higher visual clutter compared with far infrared images. Visual clutter has been shown to correlate with reduction in detection distance of pedestrians. Far infrared images are perceived as being more unusual and therefore more difficult to interpret, although the image appearance is likely related to the lower visual clutter. However, the main issue comparing the two technologies should be how well they solve the driver's problem with insufficient visibility under low beam conditions, especially of pedestrians and other vulnerable road users. With the addition of an automatic detection aid, a main issue will be whether the advantage of FIR systems will vanish given NIR systems with well performing automatic pedestrian detection functionality. The first night vision introductions did not generate the sales volumes initially expected. A renewed interest in night vision systems are however to be expected after the release of night vision systems by BMW, Mercedes and Honda, the latter with automatic pedestrian detection.

  7. The role of vision processing in prosthetic vision.

    PubMed

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  8. ACT-Vision: active collaborative tracking for multiple PTZ cameras

    NASA Astrophysics Data System (ADS)

    Broaddus, Christopher; Germano, Thomas; Vandervalk, Nicholas; Divakaran, Ajay; Wu, Shunguang; Sawhney, Harpreet

    2009-04-01

    We describe a novel scalable approach for the management of a large number of Pan-Tilt-Zoom (PTZ) cameras deployed outdoors for persistent tracking of humans and vehicles, without resorting to the large fields of view of associated static cameras. Our system, Active Collaborative Tracking - Vision (ACT-Vision), is essentially a real-time operating system that can control hundreds of PTZ cameras to ensure uninterrupted tracking of target objects while maintaining image quality and coverage of all targets using a minimal number of sensors. The system ensures the visibility of targets between PTZ cameras by using criteria such as distance from sensor and occlusion.

  9. The Recovery of Optical Quality after Laser Vision Correction

    PubMed Central

    Jung, Hyeong-Gi

    2013-01-01

    Purpose To evaluate the optical quality after laser in situ keratomileusis (LASIK) or serial photorefractive keratectomy (PRK) using a double-pass system and to follow the recovery of optical quality after laser vision correction. Methods This study measured the visual acuity, manifest refraction and optical quality before and one day, one week, one month, and three months after laser vision correction. Optical quality parameters including the modulation transfer function, Strehl ratio and intraocular scattering were evaluated with a double-pass system. Results This study included 51 eyes that underwent LASIK and 57 that underwent PRK. The optical quality three months post-surgery did not differ significantly between these laser vision correction techniques. Furthermore, the preoperative and postoperative optical quality did not differ significantly in either group. Optical quality recovered within one week after LASIK but took between one and three months to recover after PRK. The optical quality of patients in the PRK group seemed to recover slightly more slowly than their uncorrected distance visual acuity. Conclusions Optical quality recovers to the preoperative level after laser vision correction, so laser vision correction is efficacious for correcting myopia. The double-pass system is a useful tool for clinical assessment of optical quality. PMID:23908570

  10. The Ohio Contrast Cards: Visual Performance in a Pediatric Low-vision Site

    PubMed Central

    Hopkins, Gregory R.; Dougherty, Bradley E.; Brown, Angela M.

    2017-01-01

    SIGNIFICANCE This report describes the first clinical use of the Ohio Contrast Cards, a new test that measures the maximum spatial contrast sensitivity of low-vision patients who cannot recognize and identify optotypes and for whom the spatial frequency of maximum contrast sensitivity is unknown. PURPOSE To compare measurements of the Ohio Contrast Cards to measurements of three other vision tests and a vision-related quality-of-life questionnaire obtained on partially sighted students at Ohio State School for the Blind. METHODS The Ohio Contrast Cards show printed square-wave gratings at very low spatial frequency (0.15 cycle/degree). The patient looks to the left/right side of the card containing the grating. Twenty-five students (13 to 20 years old) provided four measures of visual performance: two grating card tests (the Ohio Contrast Cards and the Teller Acuity Cards) and two letter charts (the Pelli-Robson contrast chart and the Bailey-Lovie acuity chart). Spatial contrast sensitivity functions were modeled using constraints from the grating data. The Impact of Vision Impairment on Children questionnaire measured vision-related quality of life. RESULTS Ohio Contrast Card contrast sensitivity was always less than 0.19 log10 units below the maximum possible contrast sensitivity predicted by the model; average Pelli-Robson letter contrast sensitivity was near the model prediction, but 0.516 log10 units below the maximum. Letter acuity was 0.336 logMAR below the grating acuity results. The model estimated the best testing distance in meters for optimum Pelli-Robson contrast sensitivity from the Bailey-Lovie acuity as distance = 1.5 − logMAR for low-vision patients. Of the four vision tests, only Ohio Contrast Card contrast sensitivity was independently and statistically significantly correlated with students' quality of life. CONCLUSIONS The Ohio Contrast Cards combine a grating stimulus, a looking indicator behavior, and contrast sensitivity measurement. They

  11. Index mismatch aberration correction over long working distances using spatial light modulation.

    PubMed

    Gjonaj, Bergin; Johnson, Patrick; Bonn, Mischa; Domke, Katrin F

    2012-11-20

    For many microscopy applications, millimeters-long free working distances (LWD) are required. However, the high resolution and contrast of LWD objectives operated in air are lost when introducing glass and/or liquid with the sample. We propose to use spatial light modulation to correct for such beam aberrations caused by refractive index mismatches. Focusing a monochromatic laser beam with a 10 mm working distance air objective (50×, 0.5 NA) through air, glass, and water, we manage to restore a sharp, intense focus (FWHM<2λ) by adaptive beam phase shaping. Our approach offers a practical and cost-effective route to high resolution and contrast microscopy using LWD air objectives, extending their usage beyond applications in air.

  12. Impact of Pediatric Vision Impairment on Daily Life: Results of Focus Groups

    PubMed Central

    DeCarlo, Dawn K.; McGwin, Gerald; Bixler, Martha L.; Wallander, Jan; Owsley, Cynthia

    2012-01-01

    Purpose To identify through focus groups of visually impaired children and their parents, relevant content for a vision-targeted health-related quality of life questionnaire designed for children ages 6-12. Methods Six focus groups of children with vision impairment ages 6 -12 and six focus groups of their parents were conducted by trained facilitators using a guided script. Sessions were recorded, transcribed and coded per a standardized protocol for content analysis. Comments were placed in thematic categories and each coded as positive, negative or neutral. Results Twenty-four children (mean age 9.4 years) with vision impairment from a variety of causes and 23 parents participated. The child focus groups generated 1,163 comments, of which 52% (n=599) were negative, 12% (n=138) were neutral and 37% (n=426) were positive. The three most common topical areas among children were: glasses and adaptive equipment (18%), psychosocial (14%) and school (14%). The parent focus groups generated 1,952 comments of which 46% (n=895) were negative, 16% (n=323) were neutral and 38% (n=734) were positive. The three most common topical areas among parents were: school (21%), expectations or frustrations (14%) and psychosocial (13%). Conclusions Pediatric vision impairment has significant effects on health related quality of life, as reported by children with vision impairment and their parents in their own words. These findings will provide the content to guide construction of a survey instrument to assess vision-specific, health-related quality of life in children with vision impairment. PMID:22863790

  13. Protein structure-structure alignment with discrete Fréchet distance.

    PubMed

    Jiang, Minghui; Xu, Ying; Zhu, Binhai

    2008-02-01

    Matching two geometric objects in two-dimensional (2D) and three-dimensional (3D) spaces is a central problem in computer vision, pattern recognition, and protein structure prediction. In particular, the problem of aligning two polygonal chains under translation and rotation to minimize their distance has been studied using various distance measures. It is well known that the Hausdorff distance is useful for matching two point sets, and that the Fréchet distance is a superior measure for matching two polygonal chains. The discrete Fréchet distance closely approximates the (continuous) Fréchet distance, and is a natural measure for the geometric similarity of the folded 3D structures of biomolecules such as proteins. In this paper, we present new algorithms for matching two polygonal chains in two dimensions to minimize their discrete Fréchet distance under translation and rotation, and an effective heuristic for matching two polygonal chains in three dimensions. We also describe our empirical results on the application of the discrete Fréchet distance to protein structure-structure alignment.

  14. Bioactive glass-coated silicone for percutaneous devices with improved tissue interaction

    NASA Astrophysics Data System (ADS)

    Marotta, James Scott

    The discovery of bioactive glasses, in the early 1970s, has produced a material that develops a strong adherent bond with soft tissue. Many medical applications currently use silicone as an implant material, but are hindered by the formation of fibrous scar tissue surrounding the device. This fibrous scar tissue can lead to pain, infection, and/or extrusion of these devices. Bioactive ceramic materials are inherently brittle and can not be used in applications where a flexible material is needed. Therefore, the coating of existing flexible silicone medical devices, like catheters, with a bioactive glass material would give the advantages of both. The research presented here is of methods used to coat silicone with a bioactive glass powder (Bioglass°ler) and the in vitro testing of those coatings. The bioactivity of these coatings was measured using scanning electron microscopy, inductively coupled plasma spectroscopy, and Fourier transform infrared spectroscopy. It was observed that hydroxyapatite, a bonelike apatite, was formed in vitro on both the bioactive glass particles and the silicone surface between these particles. From these results a new theory was developed that related the distance between particles on a surface with the formation of an apatite layer. A critical distance between particles for the formation of an apatite layer on the substrate exists. This critical distance is a function of both the particle size and composition. In addition, a method to coat silicone catheters with bioactive glass powder is also discussed. This coated catheter could ultimately be used for improved percutaneous access in peritoneal dialysis. The one barrier to greater peritoneal dialysis use and the reason many patients switch from peritoneal to hemodialysis is recurrent exit-site infections and subsequent peritonitis. These infections are caused by the lack of a tight seal and downgrowth of epidermal tissue around the catheter at the catheter-skin interface.

  15. [Investigation of color vision in acute unilateral optic neuritis using a web-based color vision test].

    PubMed

    Kuchenbecker, J; Blum, M; Paul, F

    2016-03-01

    In acute unilateral optic neuritis (ON) color vision defects combined with a decrease in visual acuity and contrast sensitivity frequently occur. This study investigated whether a web-based color vision test is a reliable detector of acquired color vision defects in ON and, if so, which charts are particularly suitable. In 12 patients with acute unilateral ON, a web-based color vision test ( www.farbsehtest.de ) with 25 color plates (16 Velhagen/Broschmann and 9 Ishihara color plates) was performed. For each patient the affected eye was tested first and then the unaffected eye. The mean best-corrected distance visual acuity (BCDVA) in the ON eye was 0.36 ± 0.20 and 1.0 ± 0.1 in the contralateral eye. The number of incorrectly read plates correlated with the visual acuity. For the ON eye a total of 134 plates were correctly identified and 166 plates were incorrectly identified, while for the disease-free fellow eye, 276 plates were correctly identified and 24 plates were incorrectly identified. Both of the blue/yellow plates were identified correctly 14 times and incorrectly 10 times using the ON eye and exclusively correctly (24 times) using the fellow eye. The Velhagen/Broschmann plates were incorrectly identified significantly more frequently in comparison with the Ishihara plates. In 4 out of 16 Velhagen/Broschmann plates and 5 out of 9 Ishihara plates, no statistically significant differences between the ON eye and the fellow eye could be detected. The number of incorrectly identified plates correlated with a decrease in visual acuity. Red/green and blue/yellow plates were incorrectly identified significantly more frequently with the ON eye, while the Velhagen/Broschmann color plates were incorrectly identified significantly more frequently than the Ishihara color plates. Thus, under defined test conditions the web-based color vision test can also be used to detect acquired color vision defects, such as those caused by ON. Optimization of the test by

  16. Does functional vision behave differently in low-vision patients with diabetic retinopathy?--A case-matched study.

    PubMed

    Ahmadian, Lohrasb; Massof, Robert

    2008-09-01

    A retrospective case-matched study designed to compare patients with diabetic retinopathy (DR) and other ocular diseases, managed in a low-vision clinic, in four different types of functional vision. Reading, mobility, visual motor, and visual information processing were measured in the patients (n = 114) and compared with those in patients with other ocular diseases (n = 114) matched in sex, visual acuity (VA), general health status, and age, using the Activity Inventory as a Rasch-scaled measurement tool. Binocular distance visual acuity was categorized as normal (20/12.5-20/25), near normal (20/32-20/63), moderate (20/80-20/160), severe (20/200-20/400), profound (20/500-20/1000), and total blindness (20/1250 to no light perception). Both Wilcoxon matched pairs signed rank test and the sign test of matched pairs were used to compare estimated functional vision measures between DR cases and controls. Cases ranged in age from 19 to 90 years (mean age, 67.5), and 59% were women. The mean visual acuity (logMar scale) was 0.7. Based on the Wilcoxon signed rank test analyses and after adjusting the probability for multiple comparisons, there was no statistically significant difference (P > 0.05) between patients with DR and control subjects in any of four functional visions. Furthermore, diabetic retinopathy patients did not differ (P > 0.05) from their matched counterparts in goal-level vision-related functional ability and total visual ability. Visual impairment in patients with DR appears to be a generic and non-disease-specific outcome that can be explained mainly by the end impact of the disease in the patients' daily lives and not by the unique disease process that results in the visual impairment.

  17. Technical vision for robots

    NASA Astrophysics Data System (ADS)

    1985-01-01

    A new invention by scientists who have copied the structure of a human eye will help replace a human telescope-watching astronomer with a robot. It will be possible to provide technical vision not only for robot astronomers but also for their industrial fellow robots. So far, an artificial eye with dimensions close to those of a human eye discerns only black-and-white images. But already the second model of the eye is to perceive colors as well. Polymers which are suited for the role of the coat of an eye, lens, and vitreous body were applied. The retina has been replaced with a bundle of the finest glass filaments through which light rays get onto photomultipliers. They can be positioned outside the artificial eye. The main thing is to prevent great losses in the light guide.

  18. Are children with low vision adapted to the visual environment in classrooms of mainstream schools?

    PubMed

    Negiloni, Kalpa; Ramani, Krishna Kumar; Jeevitha, R; Kalva, Jayashree; Sudhir, Rachapalle Reddi

    2018-02-01

    The study aimed to evaluate the classroom environment of children with low vision and provide recommendations to reduce visual stress, with focus on mainstream schooling. The medical records of 110 children (5-17 years) seen in low vision clinic during 1 year period (2015) at a tertiary care center in south India were extracted. The visual function levels of children were compared to the details of their classroom environment. The study evaluated and recommended the chalkboard visual task size and viewing distance required for children with mild, moderate, and severe visual impairment (VI). The major causes of low vision based on the site of abnormality and etiology were retinal (80%) and hereditary (67%) conditions, respectively, in children with mild (n = 18), moderate (n = 72), and severe (n = 20) VI. Many of the children (72%) had difficulty in viewing chalkboard and common strategies used for better visibility included copying from friends (47%) and going closer to chalkboard (42%). To view the chalkboard with reduced visual stress, a child with mild VI can be seated at a maximum distance of 4.3 m from the chalkboard, with the minimum size of visual task (height of lowercase letter writing on chalkboard) recommended to be 3 cm. For 3/60-6/60 range, the maximum viewing distance with the visual task size of 4 cm is recommended to be 85 cm to 1.7 m. Simple modifications of the visual task size and seating arrangements can aid children with low vision with better visibility of chalkboard and reduced visual stress to manage in mainstream schools.

  19. Problems with vision associated with limitations or avoidance of driving in older populations.

    PubMed

    Satariano, William A; MacLeod, Kara E; Cohn, Theodore E; Ragland, David R

    2004-09-01

    This report examines the role of (a) disease processes affecting vision, (b) reported troubles with vision, (c) physical symptoms affecting the eyes, and (d) objective measures in reported driving limitation due to problems with eyesight among older drivers. Data for this study (N = 1,840) were obtained from participants in a community-based study of aging and physical performance in people age 55 or older in the city of Sonoma, California. Each of 16 visual conditions was assessed for impact on reported driving limitation due to eyesight by calculating a "risk" ratio. Then, prevalence of the condition was combined with the ratio to generate an attributable risk for that condition for vision-related limitations in driving. Each condition was significantly associated with reported limitations in driving due to eyesight. "Avoiding physical activity due to vision" (ratio = 3.4) and "trouble seeing steps up/down stairs" (ratio = 2.9) had the strongest association. However, "glasses/contacts required for driving" and "trouble with glare from sun/lights" had the highest attributable risks (35.8 and 29.4). The risk ratio is relevant for evaluating individuals; the attributable risk is relevant to planning countermeasures in populations. Addressing specific problems related to vision should substantially reduce driving limitations due to eyesight.

  20. Stroboscopic Vision as a Treatment for Retinal Slip Induced Motion Sickness

    NASA Technical Reports Server (NTRS)

    Reschke, M. F.; Somers, J. T.; Ford, G.; Krnavek, J. M.; Hwang, E. J.; Leigh, R. J.; Estrada, A.

    2007-01-01

    Motion sickness in the general population is a significant problem driven by the increasingly more sophisticated modes of transportation, visual displays, and virtual reality environments. It is important to investigate non-pharmacological alternatives for the prevention of motion sickness for individuals who cannot tolerate the available anti-motion sickness drugs, or who are precluded from medication because of different operational environments. Based on the initial work of Melvill Jones, in which post hoc results indicated that motion sickness symptoms were prevented during visual reversal testing when stroboscopic vision was used to prevent retinal slip, we have evaluated stroboscopic vision as a method of preventing motion sickness in a number of different environments. Specifically, we have undertaken a five part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness while: (1) using visual field reversal, (2) reading while riding in a car (with or without external vision present), (3) making large pitch head movements during parabolic flight, (4) during exposure to rough seas in a small boat, and (5) seated and reading in the cabin area of a UH60 Black Hawk Helicopter during 20 min of provocative flight patterns.

  1. Causes of vision impairment and assessment of need for low vision services for students of blind schools in Nepal.

    PubMed

    Kansakar, I; Thapa, H B; Salma, K C; Ganguly, S; Kandel, R P; Rajasekaran, S

    The present study is first of its kind to evaluate causes of visual impairment of blind students in Nepal and assess their need for low vision rehabilitation services. To evaluate causes of vision impairment of students enrolled in blind schools in Nepal and assess the need for low vision rehabilitation services in these students. A survey was conducted in 12 blind schools in Nepal, which were registered with Nepal Association for Welfare of Blindness (NAWB).It was conducted by a team of an ophthalmologist and an optometrist, by using standard eye examination protocols of the World Health Organization Prevention of Blindness Program (WHO/PBL). Of the 345 students enrolled in 12 schools, 285 students were examined (response rate of 82.61%). The students were in the 5 - 29 years age group. Nearly three-fourth of the children had become blind within one year of age and 52.3% visually impaired at birth and 20.7% developed vision impairment within one year of age. After refraction, 26 students (9.12%) had mild visual impairment, 21 students (7.37%) had severe visual impairment and 238 students (83.51%) were blind. The main cause of vision impairment was found to be corneal 35.79% and retina diseases, mainly dystrophy, 20.35% followed by problems with the whole globe, lens and optic nerve, accounting for 13.33%, 12.63% and 12.98% respectively. The major etiological factors were those of childhood such as Vitamin A deficiency, measles and similar causes (42.11%) followed by hereditary causes (25.26%). Of the total students examined, 48.07% were visually impaired due to preventable causes and 16.14% treatable aggregating to 64.21% of avoidable blindness. Fifty seven (28.22%) students could read smaller than 2 M print size after low vision assessment for near and 33(15.78%) students benefited with telescopic trial for distance low vision. In Nepal, renewed focus on providing best possible quality of life for visually impaired children by proper low vision assessment and eye

  2. Vision in flying insects.

    PubMed

    Egelhaaf, Martin; Kern, Roland

    2002-12-01

    Vision guides flight behaviour in numerous insects. Despite their small brain, insects easily outperform current man-made autonomous vehicles in many respects. Examples are the virtuosic chasing manoeuvres male flies perform as part of their mating behaviour and the ability of bees to assess, on the basis of visual motion cues, the distance travelled in a novel environment. Analyses at both the behavioural and neuronal levels are beginning to unveil reasons for such extraordinary capabilities of insects. One recipe for their success is the adaptation of visual information processing to the specific requirements of the behavioural tasks and to the specific spatiotemporal properties of the natural input.

  3. Selecting the Most Appropriate Primary Learning Medium for Students with Functional Vision.

    ERIC Educational Resources Information Center

    Mangold, S.; Mangold, P.

    1989-01-01

    Five considerations for determining the most appropriate learning medium for students with functional vision are: (1) working distance from the page; (2) portability of reading skills; (3) reading rates and accuracy; (4) visual fatigue; and (5) interpretation of assessment results. (Author/DB)

  4. Machine Vision Applied to Navigation of Confined Spaces

    NASA Technical Reports Server (NTRS)

    Briscoe, Jeri M.; Broderick, David J.; Howard, Ricky; Corder, Eric L.

    2004-01-01

    The reliability of space related assets has been emphasized after the second loss of a Space Shuttle. The intricate nature of the hardware being inspected often requires a complete disassembly to perform a thorough inspection which can be difficult as well as costly. Furthermore, it is imperative that the hardware under inspection not be altered in any other manner than that which is intended. In these cases the use of machine vision can allow for inspection with greater frequency using less intrusive methods. Such systems can provide feedback to guide, not only manually controlled instrumentation, but autonomous robotic platforms as well. This paper serves to detail a method using machine vision to provide such sensing capabilities in a compact package. A single camera is used in conjunction with a projected reference grid to ascertain precise distance measurements. The design of the sensor focuses on the use of conventional components in an unconventional manner with the goal of providing a solution for systems that do not require or cannot accommodate more complex vision systems.

  5. Progress in building a cognitive vision system

    NASA Astrophysics Data System (ADS)

    Benjamin, D. Paul; Lyons, Damian; Yue, Hong

    2016-05-01

    We are building a cognitive vision system for mobile robots that works in a manner similar to the human vision system, using saccadic, vergence and pursuit movements to extract information from visual input. At each fixation, the system builds a 3D model of a small region, combining information about distance, shape, texture and motion to create a local dynamic spatial model. These local 3D models are composed to create an overall 3D model of the robot and its environment. This approach turns the computer vision problem into a search problem whose goal is the acquisition of sufficient spatial understanding for the robot to succeed at its tasks. The research hypothesis of this work is that the movements of the robot's cameras are only those that are necessary to build a sufficiently accurate world model for the robot's current goals. For example, if the goal is to navigate through a room, the model needs to contain any obstacles that would be encountered, giving their approximate positions and sizes. Other information does not need to be rendered into the virtual world, so this approach trades model accuracy for speed.

  6. Computer vision syndrome: A review.

    PubMed

    Gowrisankaran, Sowjanya; Sheedy, James E

    2015-01-01

    Computer vision syndrome (CVS) is a collection of symptoms related to prolonged work at a computer display. This article reviews the current knowledge about the symptoms, related factors and treatment modalities for CVS. Relevant literature on CVS published during the past 65 years was analyzed. Symptoms reported by computer users are classified into internal ocular symptoms (strain and ache), external ocular symptoms (dryness, irritation, burning), visual symptoms (blur, double vision) and musculoskeletal symptoms (neck and shoulder pain). The major factors associated with CVS are either environmental (improper lighting, display position and viewing distance) and/or dependent on the user's visual abilities (uncorrected refractive error, oculomotor disorders and tear film abnormalities). Although the factors associated with CVS have been identified the physiological mechanisms that underlie CVS are not completely understood. Additionally, advances in technology have led to the increased use of hand-held devices, which might impose somewhat different visual challenges compared to desktop displays. Further research is required to better understand the physiological mechanisms underlying CVS and symptoms associated with the use of hand-held and stereoscopic displays.

  7. [Comparison study between biological vision and computer vision].

    PubMed

    Liu, W; Yuan, X G; Yang, C X; Liu, Z Q; Wang, R

    2001-08-01

    The development and bearing of biology vision in structure and mechanism were discussed, especially on the aspects including anatomical structure of biological vision, tentative classification of reception field, parallel processing of visual information, feedback and conformity effect of visual cortical, and so on. The new advance in the field was introduced through the study of the morphology of biological vision. Besides, comparison between biological vision and computer vision was made, and their similarities and differences were pointed out.

  8. X-ray absorption studies of chlorine valence and local environments in borosilicate waste glasses

    NASA Astrophysics Data System (ADS)

    McKeown, David A.; Gan, Hao; Pegg, Ian L.; Stolte, W. C.; Demchenko, I. N.

    2011-01-01

    Chlorine (Cl) is a constituent of certain types of nuclear wastes and its presence can affect the physical and chemical properties of silicate melts and glasses developed for the immobilization of such wastes. Cl K-edge X-ray absorption spectra (XAS) were collected and analyzed to characterize the unknown Cl environments in borosilicate waste glass formulations, ranging in Cl-content from 0.23 to 0.94 wt.%. Both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) data for the glasses show trends dependent on calcium (Ca) content. Near-edge data for the Ca-rich glasses are most similar to the Cl XANES of CaCl 2, where Cl - is coordinated to three Ca atoms, while the XANES for the Ca-poor glasses are more similar to the mineral davyne, where Cl is most commonly coordinated to two Ca in one site, as well as Cl and oxygen nearest-neighbors in other sites. With increasing Ca content in the glass, Cl XANES for the glasses approach that for CaCl 2, indicating more Ca nearest-neighbors around Cl. Reliable structural information obtained from the EXAFS data for the glasses is limited, however, to Cl sbnd Cl, Cl sbnd O, and Cl sbnd Na distances; Cl sbnd Ca contributions could not be fit to the glass data, due to the narrow k-space range available for analysis. Structural models that best fit the glass EXAFS data include Cl sbnd Cl, Cl sbnd O, and Cl sbnd Na correlations, where Cl sbnd O and Cl sbnd Na distances decrease by approximately 0.16 Å as glass Ca content increases. XAS for the glasses indicates Cl - is found in multiple sites where most Cl-sites have Ca neighbors, with oxygen, and possibly, Na second-nearest neighbors. EXAFS analyses suggest that Cl sbnd Cl environments may also exist in the glasses in minor amounts. These results are generally consistent with earlier findings for silicate glasses, where Cl - was associated with Ca 2+ and Na + in network modifier sites.

  9. Ideas for Teaching Vision and Visioning

    ERIC Educational Resources Information Center

    Quijada, Maria Alejandra

    2017-01-01

    In teaching leadership, a key element to include should be a discussion about vision: what it is, how to communicate it, and how to ensure that it is effective and shared. This article describes a series of exercises that rely on videos to illustrate different aspects of vision and visioning, both in the positive and in the negative. The article…

  10. Are children with low vision adapted to the visual environment in classrooms of mainstream schools?

    PubMed Central

    Negiloni, Kalpa; Ramani, Krishna Kumar; Jeevitha, R; Kalva, Jayashree; Sudhir, Rachapalle Reddi

    2018-01-01

    Purpose: The study aimed to evaluate the classroom environment of children with low vision and provide recommendations to reduce visual stress, with focus on mainstream schooling. Methods: The medical records of 110 children (5–17 years) seen in low vision clinic during 1 year period (2015) at a tertiary care center in south India were extracted. The visual function levels of children were compared to the details of their classroom environment. The study evaluated and recommended the chalkboard visual task size and viewing distance required for children with mild, moderate, and severe visual impairment (VI). Results: The major causes of low vision based on the site of abnormality and etiology were retinal (80%) and hereditary (67%) conditions, respectively, in children with mild (n = 18), moderate (n = 72), and severe (n = 20) VI. Many of the children (72%) had difficulty in viewing chalkboard and common strategies used for better visibility included copying from friends (47%) and going closer to chalkboard (42%). To view the chalkboard with reduced visual stress, a child with mild VI can be seated at a maximum distance of 4.3 m from the chalkboard, with the minimum size of visual task (height of lowercase letter writing on chalkboard) recommended to be 3 cm. For 3/60–6/60 range, the maximum viewing distance with the visual task size of 4 cm is recommended to be 85 cm to 1.7 m. Conclusion: Simple modifications of the visual task size and seating arrangements can aid children with low vision with better visibility of chalkboard and reduced visual stress to manage in mainstream schools. PMID:29380777

  11. A fuzzy structural matching scheme for space robotics vision

    NASA Technical Reports Server (NTRS)

    Naka, Masao; Yamamoto, Hiromichi; Homma, Khozo; Iwata, Yoshitaka

    1994-01-01

    In this paper, we propose a new fuzzy structural matching scheme for space stereo vision which is based on the fuzzy properties of regions of images and effectively reduces the computational burden in the following low level matching process. Three dimensional distance images of a space truss structural model are estimated using this scheme from stereo images sensed by Charge Coupled Device (CCD) TV cameras.

  12. Long-Term Optical Device Use by Young Adults with Low Vision

    ERIC Educational Resources Information Center

    Bachofer, Cynthia Susan

    2013-01-01

    The purpose of this study was to investigate the long-term use of optical devices by individuals who participated in a school-based comprehensive low vision program focusing on use of devices, both near and distance. Thirty-seven participants (five non-users), ages 18-28, completed phone interviews giving information on their personal…

  13. Research on Glass Frit Deposition Based on the Electrospray Process

    PubMed Central

    Liu, Yifang; Chen, Daner; Zhan, Zhan; Li, Chenlei; Zheng, Jianyi; Sun, Daoheng

    2016-01-01

    In this paper, the electrospray technology is used to easily deposit the glass frit into patterns at a micro-scale level. First, far-field electrospray process was carried out with a mixture of glass frit in the presence of ethanol. A uniform, smooth, and dense glass frit film was obtained, verifying that the electrospray technology was feasible. Then, the distance between the nozzle and the substrate was reduced to 2 mm to carry out near-field electrospray. The experimental process was improved by setting the range of the feed rate of the substrate to match both the concentration and the flow rate of the solution. Spray diameter could be less at the voltage of 2 kV, in which the glass frit film was expected to reach the minimum line width. A uniform glass frit film with a line width within the range of 400–500 μm was prepared when the speed of the substrate was 25 mm/s. It indicates that electrospray is an efficient technique for the patterned deposition of glass frit in wafer-level hermetic encapsulation. PMID:28773417

  14. [Optical and spectral parameters in Ce3+ -doped gadolinium gallium aluminum garnet glass-ceramics].

    PubMed

    Gong, Hua; Zhao, Xin; Yu, Xiao-bo; Setsuhisa, Tanabe; Lin, Hai

    2010-01-01

    The crystalline phases of Ce3+ -doped gadolinium gallium aluminum garnet (GGAG) glass-ceramics were investigated by X-ray diffraction, and the fluorescence spectra were recorded under the pumping of blue light-emitting diode (LED) using an integrating sphere of 10-inch in diameter, which connected to a CCD detector. The spectral power distribution of the glass-ceramics was obtained from the measured spectra first, and then the quantum yield was derived based on the photon distribution. The quantum yield of Ce3+ emission in GGAG glass-ceramics is 29.2%, meanwhile, the color coordinates and the correlated color temperature (CCT) of combined white light were proved to be x = 0.319, y = 0.349 and 6086 K, respectively. Although the quantum yield is a little smaller than the value in Ce3+ -doped YAG glass-ceramics, the CCT of the combined white light is much smaller than that in the latter. The optical behavior of GGAG glass-ceramics provides new vision for developing comfortable LED lighting devices.

  15. Factors influencing self-reported vision-related activity limitation in the visually impaired.

    PubMed

    Tabrett, Daryl R; Latham, Keziah

    2011-07-15

    The use of patient-reported outcome (PRO) measures to assess self-reported difficulty in visual activities is common in patients with impaired vision. This study determines the visual and psychosocial factors influencing patients' responses to self-report measures, to aid in understanding what is being measured. One hundred visually impaired participants completed the Activity Inventory (AI), which assesses self-reported, vision-related activity limitation (VRAL) in the task domains of reading, mobility, visual information, and visual motor tasks. Participants also completed clinical tests of visual function (distance visual acuity and near reading performance both with and without low vision aids [LVAs], contrast sensitivity, visual fields, and depth discrimination), and questionnaires assessing depressive symptoms, social support, adjustment to visual loss, and personality. Multiple regression analyses identified that an acuity measure (distance or near), and, to a lesser extent, near reading performance without LVAs, visual fields, and contrast sensitivity best explained self-reported VRAL (28%-50% variance explained). Significant psychosocial correlates were depression and adjustment, explaining an additional 6% to 19% unique variance. Dependent on task domain, the parameters assessed explained 59% to 71% of the variance in self-reported VRAL. Visual function, most notably acuity without LVAs, is the best predictor of self-reported VRAL assessed by the AI. Depression and adjustment to visual loss also significantly influence self-reported VRAL, largely independent of the severity of visual loss and most notably in the less vision-specific tasks. The results suggest that rehabilitation strategies addressing depression and adjustment could improve perceived visual disability.

  16. Benchmarking neuromorphic vision: lessons learnt from computer vision

    PubMed Central

    Tan, Cheston; Lallee, Stephane; Orchard, Garrick

    2015-01-01

    Neuromorphic Vision sensors have improved greatly since the first silicon retina was presented almost three decades ago. They have recently matured to the point where they are commercially available and can be operated by laymen. However, despite improved availability of sensors, there remains a lack of good datasets, while algorithms for processing spike-based visual data are still in their infancy. On the other hand, frame-based computer vision algorithms are far more mature, thanks in part to widely accepted datasets which allow direct comparison between algorithms and encourage competition. We are presented with a unique opportunity to shape the development of Neuromorphic Vision benchmarks and challenges by leveraging what has been learnt from the use of datasets in frame-based computer vision. Taking advantage of this opportunity, in this paper we review the role that benchmarks and challenges have played in the advancement of frame-based computer vision, and suggest guidelines for the creation of Neuromorphic Vision benchmarks and challenges. We also discuss the unique challenges faced when benchmarking Neuromorphic Vision algorithms, particularly when attempting to provide direct comparison with frame-based computer vision. PMID:26528120

  17. A remote assessment system with a vision robot and wearable sensors.

    PubMed

    Zhang, Tong; Wang, Jue; Ren, Yumiao; Li, Jianjun

    2004-01-01

    This paper describes an ongoing researched remote rehabilitation assessment system that has a 6-freedom double-eyes vision robot to catch vision information, and a group of wearable sensors to acquire biomechanical signals. A server computer is fixed on the robot, to provide services to the robot's controller and all the sensors. The robot is connected to Internet by wireless channel, and so do the sensors to the robot. Rehabilitation professionals can semi-automatically practise an assessment program via Internet. The preliminary results show that the smart device, including the robot and the sensors, can improve the quality of remote assessment, and reduce the complexity of operation at a distance.

  18. The research of binocular vision ranging system based on LabVIEW

    NASA Astrophysics Data System (ADS)

    Li, Shikuan; Yang, Xu

    2017-10-01

    Based on the study of the principle of binocular parallax ranging, a binocular vision ranging system is designed and built. The stereo matching algorithm is realized by LabVIEW software. The camera calibration and distance measurement are completed. The error analysis shows that the system fast, effective, can be used in the corresponding industrial occasions.

  19. The deep fovea, sideways vision and spiral flight paths in raptors.

    PubMed

    Tucker, V A

    2000-12-01

    Raptors - falcons, hawks and eagles in this study - have two regions of the retina in each eye that are specialized for acute vision: the deep fovea and the shallow fovea. The line of sight of the deep fovea points forwards and approximately 45 degrees to the right or left of the head axis, while that of the shallow fovea also points forwards but approximately 15 degrees to the right or left of the head axis. The anatomy of the foveae suggests that the deep fovea has the higher acuity. Several species of raptors in this study repeatedly moved their heads among three positions while looking at an object: straight, with the head axis pointing towards the object; or sideways to the right or left, with the head axis pointing approximately 40 degrees to the side of the object. Since raptors do not rotate their eyes noticeably in the sockets, these movements presumably cause the image of the object to fall on the shallow and deep foveae. The movements occurred approximately every 2 s on average in hawks and falcons, and approximately every 5 s in bald eagles. The proportion of time that the raptors spent looking straight or sideways at an object depended on how far away the object was. At a distances closer than 8 m, they spent more time looking at the object straight, but as the distance increased to 21 m, they spent more time looking at it sideways. At distances of 40 m or more, raptors looked sideways at the object 80 % or more of the time. This dependence of head position on distance suggests that raptors use their more acute sideways vision to look at distant objects and sacrifice acuity for stereoscopic binocular vision to look at close objects. Having their most acute vision towards the side causes a conflict in raptors such as falcons, which dive at prey from great distances at high speeds: at a speed of 70 m s(-)(1), turning their head sideways to view the prey straight ahead with high visual acuity may increase aerodynamic drag by a factor of 2 or more and slow

  20. Access to low-vision rehabilitation services: barriers and enablers.

    PubMed

    Matti, Albert I; Pesudovs, Konrad; Daly, Andrew; Brown, Margaret; Chen, Celia S

    2011-03-01

    The current mismatch between the need for and uptake of low-vision services has been attributed to various barriers including different service delivery models and referral pathways. This study evaluates the referral pathway and low-vision service provision of the Royal Society for the Blind (RSB) in South Australia. All new referrals from the 2008-2009 financial year to the RSB were reviewed. Initially, patients were contacted by a triage officer within one week of referral. Initial appointments were made in the Low Vision Clinic with a multidisciplinary team. Reasons for declining the appointment or non-attendance were tracked via telephone. There were 1116 patients referred over a 12-month period and 1082 (97 per cent) were reviewed in the Low Vision Clinic. Most attendees (92 per cent) lived within 50 kilometres of the clinic. There were 34 referred patients, who declined or did not attend the assessment. All non-attendees also lived within 50 kilometres of the Low Vision Centre. Concurrent major health problems (27 per cent) and patients not feeling the need for low-vision rehabilitation (27 per cent) were the most common reasons for not accessing the service. Only 125 patients (11.6 per cent) accessed volunteer transport services and only 24 patients (2.2 per cent) needed an interpreter service. The attendance rate is significantly higher than in other published studies. The distance to travel or transport difficulties were not significant barriers. Patient perception that either the service was not required or would not help them was the main barrier. The referral and triage process appeared to be a major enabler of low-vision service uptake. © 2010 The Authors. Clinical and Experimental Optometry © 2010 Optometrists Association Australia.

  1. Digimarc Discover on Google Glass

    NASA Astrophysics Data System (ADS)

    Rogers, Eliot; Rodriguez, Tony; Lord, John; Alattar, Adnan

    2015-03-01

    This paper reports on the implementation of the Digimarc® Discover platform on Google Glass, enabling the reading of a watermark embedded in a printed material or audio. The embedded watermark typically contains a unique code that identifies the containing media or object and a synchronization signal that allows the watermark to be read robustly. The Digimarc Discover smartphone application can read the watermark from a small portion of printed image presented at any orientation or reasonable distance. Likewise, Discover can read the recently introduced Digimarc Barcode to identify and manage consumer packaged goods in the retail channel. The Digimarc Barcode has several advantages over the traditional barcode and is expected to save the retail industry millions of dollars when deployed at scale. Discover can also read an audio watermark from ambient audio captured using a microphone. The Digimarc Discover platform has been widely deployed on the iPad, iPhone and many Android-based devices, but it has not yet been implemented on a head-worn wearable device, such as Google Glass. Implementing Discover on Google Glass is a challenging task due to the current hardware and software limitations of the device. This paper identifies the challenges encountered in porting Discover to the Google Glass and reports on the solutions created to deliver a prototype implementation.

  2. Distance- and near-visual impairment in rural Chinese adults in Kailu, Inner Mongolia.

    PubMed

    Cheng, Fang; Shan, Li; Song, Wulian; Fan, Pan; Yuan, Huiping

    2016-06-01

    To investigate the prevalence and causes of distance-visual impairment and near-vision impairment in a rural Chinese population in Inner Mongolia. A population-based, cross-sectional study design was used to identify visual impairment in the Chinese aged 40 years and older living in Kailu County, Inner Mongolia. Low vision, blindness and near-visual impairment (NVI) were defined according to World Health Organization (WHO) criteria. The overall prevalence of blindness and visual impairment based on the presenting visual acuity (VA) was 2.2% (95% CI: 1.8-2.6) and 9.8% (95% CI: 8.9-10.6), respectively, and was adjusted to 0.9% (95% CI: 0.6-1.2) and 4.7% (95% CI: 4.1-5.3) using best-corrected visual acuity (BCVA), respectively. Taking the presenting VA into consideration, the leading cause of visual impairment and blindness was cataract (40.3%, 40.9%), followed by uncorrected refractive error (26.6%, 28.2%). According to the BCVA, the main cause of visual impairment and blindness was cataract (48.3%, 41.3%) followed by glaucoma (19.0%, 23.9%). Among the examined subjects, 80.3% had NVI, and 51.7% had presbyopia. Major barriers reported by NVI persons without near correction were lack of money to purchase prescription glasses and poor quality of the available ones (43.2%). Visual impairment is a serious public health problem, and the main causes leading to visual impairment are treatable and preventable in the rural Chinese population in Inner Mongolia. Presbyopia, together with the low rate of spectacles and lack of appropriate refractive and presbyopia spectacles, is highly prevalent in rural China. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Cognitive control predicted by color vision, and vice versa.

    PubMed

    Colzato, Lorenza S; Sellaro, Roberta; Hulka, Lea M; Quednow, Boris B; Hommel, Bernhard

    2014-09-01

    One of the most important functions of cognitive control is to continuously adapt cognitive processes to changing and often conflicting demands of the environment. Dopamine (DA) has been suggested to play a key role in the signaling and resolution of such response conflict. Given that DA is found in high concentration in the retina, color vision discrimination has been suggested as an index of DA functioning and in particular blue-yellow color vision impairment (CVI) has been used to indicate a central hypodopaminergic state. We used color discrimination (indexed by the total color distance score; TCDS) to predict individual differences in the cognitive control of response conflict, as reflected by conflict-resolution efficiency in an auditory Simon task. As expected, participants showing better color discrimination were more efficient in resolving response conflict. Interestingly, participants showing a blue-yellow CVI were associated with less efficiency in handling response conflict. Our findings indicate that color vision discrimination might represent a promising predictor of cognitive controlability in healthy individuals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Vision in former very low birthweight young adults with and without retinopathy of prematurity compared with term born controls: the NZ 1986 VLBW follow-up study.

    PubMed

    Darlow, Brian A; Elder, Mark J; Kimber, Bridget; Martin, Julia; Horwood, L John

    2017-12-06

    There are few data on visual outcomes in adulthood of former very low birthweight (VLBW; <1500 g) infants. We aimed to assess vision at 27-29 years in a national cohort of VLBW infants born in 1986 and assessed for retinopathy of prematurity (ROP) when no treatment was available, compared with term born controls. The cohort and controls attended a 2-day assessment in Christchurch as part of a larger study. Visual assessment included glasses prescription measured by focimeter, logarithm of the minimum angle of resolution (logMAR) distance visual acuity (VA), contrast sensitivity, autorefraction, retinal photographs and a questionnaire on vision-related everyday activities. Rates of reduced VA and myopia in the VLBW cohort at 27-29 were compared with the results of vision testing at 7-8 years. 250 VLBW adults (77% those alive) gave study consent and 229 (45 with a history of ROP) were assessed in Christchurch, plus 100 term born controls. VLBW adults with ROP had reduced VA compared with no ROP and controls (mean logMAR score (SD); 0.003 (0.19), -0.021 (0.16), -0.078 (0.09), P=0.001). There were no differences in myopia (>2 D) between the groups but high myopia (>5 D) was confined to those with ROP. VLBW adults with ROP drove a car less often and had higher difficulties with everyday activities scores due to eyesight. Between 7-8 and 27-29 years rates of reduced VA were stable but myopia increased. Former VLBW young adults with ROP have ongoing problems with vision affecting daily living and should continue in regular ophthalmological review. ACTRN12612000995875, Pre-results . © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Visual risk factors for falls in older people.

    PubMed

    Lord, Stephen R

    2006-09-01

    Poor vision reduces postural stability and significantly increases the risk of falls and fractures in older people. Most studies have found that poor visual acuity increases the risk of falls. However, studies that have included multiple visual measures have found that reduced contrast sensitivity and depth perception are the most important visual risk factors for falls. Multifocal glasses may add to this risk because their near-vision lenses impair distance contrast sensitivity and depth perception in the lower visual field. This reduces the ability of an older person to detect environmental hazards. There is now evidence that maximising vision through cataract surgery is an effective strategy for preventing falls. Further randomised controlled trials are required to determine whether individual strategies (such as restriction of use of multifocal glasses) or multi-strategy visual improvement interventions can significantly reduce falls in older people. Public health initiatives are required to raise awareness in older people and their carers of the importance of regular eye examinations and use of appropriate prescription glasses.

  6. Simulating age-related changes in color vision to assess the ability of older adults to take medication.

    PubMed

    Skomrock, Lindsay K; Richardson, Virginia E

    2010-03-01

    To determine if simulated, age-related changes in color vision can adversely affect one's ability to properly take medication as simulated by bead selection. Randomized controlled study. University site. University students 18 to 26 years of age without eye disorders that would affect color vision. Yellow-lens glasses to represent age-related color vision changes. The number of correct beads selected and rating of task difficulty. The secondary outcomes were participants' responses based on which colors and color pairs were most difficult to discern and strategies they might have used to select beads. The control group had no difficulties in selecting the appropriate beads, while the experimental group had significantly more mistakes, particularly with colors in the blue-violet spectrum. Average scores for the total number correct for the control and experimental groups were 36 (100%) and 27 (74.4%), P < 0.001, respectively, out of a possible 36 correct. Declines in color vision with age can adversely affect an individual's abilities to appropriately select medications. For patients taking several medications, declines in color vision should be considered when counseling older persons on strategies for compliance. Although more studies are still needed to further generalize these findings to the geriatric population, this study has shown color vision can adversely affect medication compliance.

  7. Real-time machine vision system using FPGA and soft-core processor

    NASA Astrophysics Data System (ADS)

    Malik, Abdul Waheed; Thörnberg, Benny; Meng, Xiaozhou; Imran, Muhammad

    2012-06-01

    This paper presents a machine vision system for real-time computation of distance and angle of a camera from reference points in the environment. Image pre-processing, component labeling and feature extraction modules were modeled at Register Transfer (RT) level and synthesized for implementation on field programmable gate arrays (FPGA). The extracted image component features were sent from the hardware modules to a soft-core processor, MicroBlaze, for computation of distance and angle. A CMOS imaging sensor operating at a clock frequency of 27MHz was used in our experiments to produce a video stream at the rate of 75 frames per second. Image component labeling and feature extraction modules were running in parallel having a total latency of 13ms. The MicroBlaze was interfaced with the component labeling and feature extraction modules through Fast Simplex Link (FSL). The latency for computing distance and angle of camera from the reference points was measured to be 2ms on the MicroBlaze, running at 100 MHz clock frequency. In this paper, we present the performance analysis, device utilization and power consumption for the designed system. The FPGA based machine vision system that we propose has high frame speed, low latency and a power consumption that is much lower compared to commercially available smart camera solutions.

  8. The perception of distances and spatial relationships in natural outdoor environments.

    PubMed

    Norman, J Farley; Crabtree, Charles E; Clayton, Anna Marie; Norman, Hideko F

    2005-01-01

    The ability of observers to perceive distances and spatial relationships in outdoor environments was investigated in two experiments. In experiment 1, the observers adjusted triangular configurations to appear equilateral, while in experiment 2, they adjusted the depth of triangles to match their base width. The results of both experiments revealed that there are large individual differences in how observers perceive distances in outdoor settings. The observers' judgments were greatly affected by the particular task they were asked to perform. The observers who had shown no evidence of perceptual distortions in experiment 1 (with binocular vision) demonstrated large perceptual distortions in experiment 2 when the task was changed to match distances in depth to frontal distances perpendicular to the observers' line of sight. Considered as a whole, the results indicate that there is no single relationship between physical and perceived space that is consistent with observers' judgments of distances in ordinary outdoor contexts.

  9. Wearable Improved Vision System for Color Vision Deficiency Correction

    PubMed Central

    Riccio, Daniel; Di Perna, Luigi; Sanniti Di Baja, Gabriella; De Nino, Maurizio; Rossi, Settimio; Testa, Francesco; Simonelli, Francesca; Frucci, Maria

    2017-01-01

    Color vision deficiency (CVD) is an extremely frequent vision impairment that compromises the ability to recognize colors. In order to improve color vision in a subject with CVD, we designed and developed a wearable improved vision system based on an augmented reality device. The system was validated in a clinical pilot study on 24 subjects with CVD (18 males and 6 females, aged 37.4 ± 14.2 years). The primary outcome was the improvement in the Ishihara Vision Test score with the correction proposed by our system. The Ishihara test score significantly improved (\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$p = 0.03$ \\end{document}) from 5.8 ± 3.0 without correction to 14.8 ± 5.0 with correction. Almost all patients showed an improvement in color vision, as shown by the increased test scores. Moreover, with our system, 12 subjects (50%) passed the vision color test as normal vision subjects. The development and preliminary validation of the proposed platform confirm that a wearable augmented-reality device could be an effective aid to improve color vision in subjects with CVD. PMID:28507827

  10. Distance telescopes: a survey of user success.

    PubMed

    Lowe, J B; Rubinstein, M P

    2000-05-01

    The distance telescope has a historical reputation for causing difficulties in prescribing and adaptation. Hence, we considered that a retrospective survey of patients at Nottingham Low Vision Clinic might elucidate specific attributes that influence an individual patient's success in using a distance telescope. From 142 patients prescribed distance telescopes since the Clinic's inception, 133 apparently remained users and were mailed a preliminary three-question enquiry about usage of their distance telescopes. The 87 respondents were followed up with questionnaire 2, requesting explicit information about usage, namely frequency, degree of ease or difficulty, and purpose. Older patients required higher magnification (p < 0.025). Seventeen of 74 respondents to questionnaire 2 had various adaptational problems, which are discussed; 57 of 74 patients found their distance telescopes easy to use, and 49 of 57 were frequent users. Thus, ease and frequency are linked (p < 0.05). People tended to use their distance telescopes outdoors and indoors with similar frequency (p > or = 0.29). Adaptation was found to be unrelated to visual acuity, binocularity/monocularity, ocular pathology, or restricted mobility; magnification seemed to be influential, although not significantly. Aging did not significantly impede adaptation. We infer that the universal criterion for selecting treatable patients seems to be personality type. We conclude that adaptation to a device is dependent upon active recognition of its benefits, paralleled with a tolerance of its constraints, which combine to make usage easy and regular on at least one common task.

  11. Interaction of Cracks Between Two Adjacent Indents in Glass

    NASA Technical Reports Server (NTRS)

    Choi, S. R.; Salem, J. A.

    1993-01-01

    Experimental observations of the interaction behavior of cracks between two adjacent indents were made using an indentation technique in soda-lime glass. It was specifically demonstrated how one indent crack initiates and propagates in the vicinity of another indent crack. Several types of crack interactions were examined by changing the orientation and distance of one indent relative to the other. It was found that the residual stress field produced by elastic/plastic indentation has a significant influence on controlling the mode of crack interaction. The interaction of an indent crack with a free surface was also investigated for glass and ceramic specimens.

  12. Through-the-thickness selective laser ablation of ceramic coatings on soda-lime glass

    NASA Astrophysics Data System (ADS)

    Romoli, L.; Khan, M. M. A.; Valentini, M.

    2017-05-01

    This paper investigates through-thickness laser ablation characteristics of ceramic coating deposited on the bottom surface of the soda-lime glass substrate. Experimental studies were focused on determining the effects of energy density, hatch distance and coating color on the ablation completion index. Effect of glass thickness was also tested to verify the robustness of the designed process. Up to a certain threshold limit, the ablation completion index is energy-limited and has an inverse U-shape relationship with the energy density input. Since greater hatch distance means faster ablation and lesser ablation completion index, there must be a tradeoff between ablation completion index and hatch distance. During through-thickness laser ablation of ceramic coating, energy density input should be in the range of 0.049 J/mm2 - 0.251 J/mm2 for black ceramic coating and 0.112 J/mm2 - 0.251 J/mm2 for other coatings. Finally, the designed process is capable of ablating the ceramic coating effectively through varied thickness.

  13. Glass light pipes for solar concentration

    NASA Astrophysics Data System (ADS)

    Madsen, C. K.; Dogan, Y.; Morrison, M.; Hu, C.; Atkins, R.

    2018-02-01

    Glass waveguides are fabricated using laser processing techniques that have low optical loss with >90% optical throughput. Advanced light pipes are demonstrated, including angled facets for turning mirrors used for lens-to-light pipe coupling, tapers that increase the concentration, and couplers for combining the outputs from multiple lens array elements. Because they are fabricated from glass, these light pipes can support large optical concentrations and propagate broadband solar over long distances with minimal loss and degradation compared to polymer waveguides. Applications include waveguiding solar concentrators using multi-junction PV cells, solar thermal applications and remoting solar energy, such as for daylighting. Ray trace simulations are used to estimate the surface smoothness required to achieve low loss. Optical measurements for fabricated light pipes are reported for use in waveguiding solar concentrator architectures.

  14. Heading assessment by "tunnel vision" patients and control subjects standing or walking in a virtual reality environment.

    PubMed

    Apfelbaum, Henry; Pelah, Adar; Peli, Eli

    2007-01-01

    Virtual reality locomotion simulators are a promising tool for evaluating the effectiveness of vision aids to mobility for people with low vision. This study examined two factors to gain insight into the verisimilitude requirements of the test environment: the effects of treadmill walking and the suitability of using controls as surrogate patients. Ten "tunnel vision" patients with retinitis pigmentosa (RP) were tasked with identifying which side of a clearly visible obstacle their heading through the virtual environment would lead them, and were scored both on accuracy and on their distance from the obstacle when they responded. They were tested both while walking on a treadmill and while standing, as they viewed a scene representing progress through a shopping mall. Control subjects, each wearing a head-mounted field restriction to simulate the vision of a paired patient, were also tested. At wide angles of approach, controls and patients performed with a comparably high degree of accuracy, and made their choices at comparable distances from the obstacle. At narrow angles of approach, patients' accuracy increased when walking, while controls' accuracy decreased. When walking, both patients and controls delayed their decisions until closer to the obstacle. We conclude that a head-mounted field restriction is not sufficient for simulating tunnel vision, but that the improved performance observed for walking compared to standing suggests that a walking interface (such as a treadmill) may be essential for eliciting natural perceptually-guided behavior in virtual reality locomotion simulators.

  15. Strong focusing effect of 660 nm laser by microsized tapered glass tubes with different diameters

    NASA Astrophysics Data System (ADS)

    Lin, Chongnan; Luo, Xujia; Zhu, Xiaoyang; Zhu, Li; Wang, Hongcheng; Zhang, Ao; Xu, Runyu; Qu, Zheng; Chen, Ximeng; Zhang, Weiyi; Shao, Jianxiong

    2017-09-01

    A laser with a wavelength of 660 nm was focused by microsized tapered glass tubes with different diameters of the exit. By using the 3-μm optical fiber and micrometer displacement stages, we measured the light intensity distribution around the focal spot, the focal distance, and the transmission coefficient of the light transmitted through these tubes. The focusing effect for the glass tubes with smaller outlet diameters of the exit was found to be much stronger than those with larger diameters of the exit. Furthermore, the dependence of the size and distance and the maximum intensity of the focal spot on the tubes' diameter of exit are obtained.

  16. Visual and Refractive Outcomes following Bilateral Implantation of Extended Range of Vision Intraocular Lens with Micromonovision

    PubMed Central

    Ganesh, Sri; Relekar, Kirti J.

    2018-01-01

    Purpose To evaluate the outcomes following bilateral ERV intraocular lens implantation with micromonovision. Methods 25 subjects underwent bilateral Tecnis Symfony IOL implantation with micromonovision. The dominant eye was targeted for emmetropia and the nondominant eye for myopia of −0.75 D. Uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CIVA), and near visual acuity (UNVA, DCNVA); reading performance; defocus curve; and contrast sensitivity were studied. Follow-ups were conducted at 1 week and 1 and 6 months postoperatively. Results At 6 months postoperatively, the mean binocular UDVA, CDVA, UNVA, and DCNVA were −0.036 ± 0.09, −0.108 ± 0.07, 0.152 ± 0.11, and 0.216 ± 0.10 logMAR, respectively. Binocular UIVA and DCIVA were 0.048 ± 0.09 and 0.104 ± 0.08 logMAR, respectively, at 60 cm and −0.044 ± 0.09 and 0.012 ± 0.09 logMAR, respectively, at 80 cm. All patients had ≥0.2 logMAR UDVA and UNVA. Reading acuity and reading speeds showed improvement over time. Between defocus range of −2.50 and +1.00 D, the visual acuity remained ≥0.2 logMAR. Contrast sensitivity scores were within the normal range. 4 patients used reading glasses for very fine print. Conclusion Bilateral ERV IOL implantation leads to excellent outcomes for far and intermediate vision, satisfactory outcomes for near vision, and good tolerance to micromonovision at the end of the 6 months. This trial is registered with CTRI/2015/10/006246. PMID:29545954

  17. Experimental evidences of the Gardner phase in a granular glass

    NASA Astrophysics Data System (ADS)

    Dauchot, Olivier; Seguin, Antoine

    The constituent particles of a glass are caged by their neighbors and thus cannot relax density fluctuations. This is also true for hard particles under compression. The associated slowing down of the dynamics is related to a complex free energy landscape. It was recently shown theoretically that the hard sphere glass in infinite dimension undergoes a Gardner transition, at which the glass basin breaks into a hierarchy of marginally stable sub-basins. This was very recently confirmed in simulations of 2d and 3d hard sphere (HS) glasses. We present the first direct experimental evidences of the Gardner phase, taking advantage of a well controlled granular experiment, which has already proven to successfully probe the vicinity of the jamming transition in a bi-dimensional granular glass former. More precisely, we perform independent compressions of a carefully prepared granular glass and show that for large enough compression, the final state differs from one compression to another. To do so we compare the average cage size within one state, and the average distance separating the cages of the same particles across successive compression cycles. The latter plateaus to a constant value, when entering the Gardner phase.

  18. Analysis of Nd3+:glass, solar-pumped, high-powr laser systems

    NASA Technical Reports Server (NTRS)

    Zapata, L. E.; Williams, M. D.

    1989-01-01

    The operating characteristics of Nd(3+):glass lasers energized by a solar concentrator were analyzed for the hosts YAG, silicate glass, and phosphate glass. The modeling is based on the slab zigzag laser geometry and assumes that chemical hardening methods for glass are successful in increasing glass hardness by a factor of 4. On this basis, it was found that a realistic 1-MW solar-pumped laser might be constructed from phosphate glass 4 sq m in area and 2 mm thick. If YAG were the host medium, a 1-MW solar-pumped laser need only be 0.5 sq m in area and 0.5 cm thick, which is already possible. In addition, Nd(3+) doped glass fibers were found to be excellent solar-pumped laser candidates. The small diameter of fibers eliminates thermal stress problems, and if their diameter is kept small (10 microns), they propagate a Gaussian single mode which can be expanded and transmitted long distances in space. Fiber lasers could then be used for communications in space or could be bundled and the individual beams summed or phase-matched for high-power operation.

  19. Jump events in a 3D Edwards-Anderson spin glass

    NASA Astrophysics Data System (ADS)

    Mártin, Daniel A.; Iguain, José Luis

    2017-11-01

    The statistical properties of infrequent particle displacements, greater than a certain distance, are known as jump dynamics in the context of structural glass formers. We generalize the concept of a jump to the case of a spin glass, by dividing the system into small boxes, and considering the infrequent cooperative spin flips in each box. Jumps defined this way share similarities with jumps in structural glasses. We perform numerical simulations for the 3D Edwards-Anderson model, and study how the properties of these jumps depend on the waiting time after a quench. Similar to the results for structural glasses, we find that while jump frequency depends strongly on time, the jump duration and jump length are roughly stationary. At odds with some results reported on studies of structural glass formers, at long enough times, the rest time between jumps varies as the inverse of jump frequency. We give a possible explanation for this discrepancy. We also find that our results are qualitatively reproduced by a fully-connected trap model.

  20. Nanoscale surface modification of glass using a 1064 nm pulsed laser

    NASA Astrophysics Data System (ADS)

    Theppakuttai, Senthil; Chen, Shaochen

    2003-07-01

    We report a method to produce nanopatterns on borosilicate glass by a Nd:yttrium-aluminum-garnet laser (10 ns, 1064 nm), using silica nanospheres. Nonlinear absorption of the enhanced optical field between the spheres and glass sample is believed to be the primary reason for the creation of nanofeatures on the glass substrate. By shining the laser beam from the backside of the glass sample, the scattering effects are minimized and only the direct field enhancement due to the spheres is utilized for surface patterning. To confirm this, calculations based on the Mie scattering theory were performed, and the resulting intensity as a function of scattering angles are presented. The nanofeatures thus obtained by this method are 350 nm in diameter and the distance between them is around 640 nm, which is same as the size of spheres used.

  1. Camera-based micro interferometer for distance sensing

    NASA Astrophysics Data System (ADS)

    Will, Matthias; Schädel, Martin; Ortlepp, Thomas

    2017-12-01

    Interference of light provides a high precision, non-contact and fast method for measurement method for distances. Therefore this technology dominates in high precision systems. However, in the field of compact sensors capacitive, resistive or inductive methods dominates. The reason is, that the interferometric system has to be precise adjusted and needs a high mechanical stability. As a result, we have usual high-priced complex systems not suitable in the field of compact sensors. To overcome these we developed a new concept for a very small interferometric sensing setup. We combine a miniaturized laser unit, a low cost pixel detector and machine vision routines to realize a demonstrator for a Michelson type micro interferometer. We demonstrate a low cost sensor smaller 1cm3 including all electronics and demonstrate distance sensing up to 30 cm and resolution in nm range.

  2. Do school classrooms meet the visual requirements of children and recommended vision standards?

    PubMed

    Negiloni, Kalpa; Ramani, Krishna Kumar; Sudhir, Rachapalle Reddi

    2017-01-01

    Visual demands of school children tend to vary with diverse classroom environments. The study aimed to evaluate the distance and near Visual Acuity (VA) demand in Indian school classrooms and their comparison with the recommended vision standards. The distance and near VA demands were assessed in 33 classrooms (grades 4 to 12) of eight schools. The VA threshold demand relied on the smallest size of distance and near visual task material and viewing distance. The logMAR equivalents of minimum VA demand at specific seating positions (desk) and among different grades were evaluated. The near threshold was converted into actual near VA demand by including the acuity reserve. The existing dimensions of chalkboard and classroom, gross area in a classroom per student and class size in all the measured classrooms were compared to the government recommended standards. In 33 classrooms assessed (35±10 students per room), the average distance and near logMAR VA threshold demand was 0.31±0.17 and 0.44±0.14 respectively. The mean distance VA demand (minimum) in front desk position was 0.56±0.18 logMAR. Increased distance threshold demand (logMAR range -0.06, 0.19) was noted in 7 classrooms (21%). The mean VA demand in grades 4 to 8 and grades 9 to 12 was 0.35±0.16 and 0.24±0.16 logMAR respectively and the difference was not statistically significant (p = 0.055). The distance from board to front desk was greater than the recommended standard of 2.2m in 27 classrooms (82%). The other measured parameters were noted to be different from the proposed standards in majority of the classrooms. The study suggests the inclusion of task demand assessment in school vision screening protocol to provide relevant guidance to school authorities. These findings can serve as evidence to accommodate children with mild to moderate visual impairment in the regular classrooms.

  3. Correlation Between Near-Vision Acuity and the Incidence of Peritoneal Dialysis-Related Infections.

    PubMed

    Kojima, Shigeki; Sakurada, Tsutomu; Koitabashi, Kenichiro; Kojima, Kaori; Watanabe, Shiika; Uchida, Daisuke; Kaneshiro, Nagayuki; Konno, Yusuke; Shibagaki, Yugo

    Peritoneal dialysis (PD)-related infections (PDIs) such as peritonitis, exit-site infection, and tunnel infection are serious complications affecting patients on PD. Because patients with diabetes (DM) and of older age have increased in number in Japan, the number of patients with visual impairment is estimated also to have increased. Near vision is necessary for performing proper PD daily care. However, no studies have reported whether visual impairment is likely to increase the risk of PDIs.Our study included 31 PD patients (16 men, 15 women; mean age: 61.5 ± 11.8 years; mean PD duration: 27.3 ± 20.3 months; 38.7% with DM; 54.8% wearing glasses) who performed their own PD care. At our facility and related facilities, we used a standard near-vision test chart, which classifies vision into 12 grades, from 0.1 (poor) to 1.5 (clear), to assess near-vision binocular visual acuity in those patients between March 2015 and September 2015. In addition, we retrospectively examined the medical records of the patients to determine their history of PDIs. We then evaluated the correlation between near-vision acuity and the incidence of PDIs.Mean measured near-vision acuity was 0.61 ± 0.29, and we observed no significant difference in the visual acuity of patients with and without DM (0.55 ± 0.31 vs. 0.63 ± 0.26 respectively, p = 0.477). In addition, we observed no significant difference in the incidence of PDIs between patients with and without DM (1.298 ± 1.609 per year vs. 1.164 ± 0.908 per year respectively, p = 0.804). We did not find a correlation between near-vision acuity and the incidence of PDIs (r = -0.071, p = 0.795).

  4. From Assessment to Implementation: Using Qualitative Interviews to Inform Distance Learning Library Services

    ERIC Educational Resources Information Center

    Wharton, Lindsey N.

    2017-01-01

    While broad assessment projects are often used to steer library strategic planning initiatives, this article will present the benefits of qualitative interviews with distance learning constituents as a framework for developing a focused vision and targeted services. This article will describe the planning and execution of an assessment project…

  5. A PC-based shutter glasses controller for visual stimulation using multithreading in LabWindows/CVI.

    PubMed

    Gramatikov, Ivan; Simons, Kurt; Guyton, David; Gramatikov, Boris

    2017-05-01

    Amblyopia, commonly known as "lazy eye," is poor vision in an eye from prolonged neurologic suppression. It is a major public health problem, afflicting up to 3.6% of children, and will lead to lifelong visual impairment if not identified and treated in early childhood. Traditional treatment methods, such as occluding or penalizing the good eye with eye patches or blurring eye drops, do not always yield satisfactory results. Newer methods have emerged, based on liquid crystal shutter glasses that intermittently occlude the better eye, or alternately occlude the two eyes, thus stimulating vision in the "lazy" eye. As yet there is no technology that allows easy and efficient optimization of the shuttering characteristics for a given individual. The purpose of this study was to develop an inexpensive, computer-based system to perform liquid crystal shuttering in laboratory and clinical settings to help "wake up" the suppressed eye in amblyopic patients, and to help optimize the individual shuttering parameters such as wave shape, level of transparency/opacity, frequency, and duty cycle of the shuttering. We developed a liquid crystal glasses controller connected by USB cable to a PC computer. It generates the voltage waveforms going to the glasses, and has potentiometer knobs for interactive adjustments by the patient. In order to achieve good timing performance in this bidirectional system, we used multithreading programming techniques with data protection, implemented in LabWindows/CVI. The hardware and software developed were assessed experimentally. We achieved an accuracy of ±1Hz for the frequency, and ±2% for the duty cycle of the occlusion pulses. We consider these values to be satisfactory for the purpose of optimizing the visual stimulation by means of shutter glasses. The system can be used for individual optimization of shuttering attributes by clinicians, for training sessions in clinical settings, or even at home, aimed at stimulating vision in the

  6. From dichoptic to dichotic: historical contrasts between binocular vision and binaural hearing.

    PubMed

    Wade, Nicholas J; Ono, Hiroshi

    2005-01-01

    Phenomena involving vision with two eyes have been commented upon for several thousand years whereas those concerned with hearing with two ears have a much more recent history. Studies of binocular vision and binaural hearing are contrasted with respect to the singleness of the percept, experimental manipulations of dichoptic and dichotic stimuli, eye and ear dominance, spatial localisation, and the instruments used to stimulate the paired organs. One of the principal phenomena that led to studies of dichotic hearing was dichoptic colour mixing. There was similar disagreement regarding whether colours or sounds could be combined when presented to different paired organs. Direction and distance in visual localisation were analysed before those for auditory localisation, partly due to difficulties in controlling the stimuli. Instruments for investigating binocular vision, like the stereoscope and pseudoscope, were invented before those for binaural hearing, like the stethophone and pseudophone.

  7. Vision development over an extended follow-up period in babies after successful vitrectomy for stage 4b retinopathy of prematurity.

    PubMed

    Gadkari, Salil; Kamdar, Rushita; Kulkarni, Sucheta; Deshpande, Madan; Taras, Sudhir

    2015-05-01

    To demonstrate improvement in the vision of babies after successful vitrectomy for stage 4b retinopathy of prematurity (ROP) over an extended period of time. This was an observational prospective case series. Eight babies who had undergone successful vitrectomy in either their only seeing eye (or both eyes) with stage 4b ROP were followed up post-operatively for a period of 80 weeks or more. Vision with Teller acuity chart, refraction, binocular indirect ophthalmoscopy, and documentation with RetCam was done at each visit. Vision of the (only/better) seeing operated eye with corrective glasses was graded for the purpose of statistical evaluation. Paired t test was performed to compare the vision prior to 30 weeks and at or after 80 weeks. Statistically significant improvement in vision was noted at or after 80 weeks as compared to the vision recorded before 30 weeks (p = 0.0062). Unlike in adult intraocular surgeries where stable visual acuity is reached well before 30 weeks, continuing improvement at 80 weeks and beyond is noted. Gradual restoration of the retinal architecture and plasticity of the infant's developing brain are thought to be responsible.

  8. Retrospective data on causes of childhood vision impairment in Eritrea.

    PubMed

    Gyawali, Rajendra; Bhayal, Bharat Kumar; Adhikary, Rabindra; Shrestha, Arjun; Sah, Rabindra Prasad

    2017-11-22

    Proper information on causes of childhood vision loss is essential in developing appropriate strategies and programs to address such causes. This study aimed at identifying the causes of vision loss in children attending the national referral eye hospital with the only pediatric ophthalmology service in Eritrea. A retrospective data review was conducted for all the children (< 16 years of age) who attended Berhan Aiyni National Referral Eye Hospital in five years period from January 2011 to December 2015. Causes of vision loss for children with vision impairment (recorded visual acuity less than 6/18 for distance in the better eye) was classified by the anatomical site affected and by underlying etiology based on the timing of the insult and causal factor. The medical record cards of 22,509 children were reviewed, of whom 249 (1.1%) were visually impaired. The mean age of the participants was 7.82 ± 5.43 years (range: one month to 16 years) and male to female ratio was 1:0.65. The leading causes of vision loss were cataract (19.7%), corneal scars (15.7%), refractive error and amblyopia (12.1%), optic atrophy (6.4%), phthisis bulbi (6.4%), aphakia (5.6%) and glaucoma (5.2%). Childhood factors including trauma were the leading causes identified (34.5%) whereas other causes included hereditary factors (4%), intrauterine factors (2.0%) and perinatal factors (4.4%). In 55.0% of the children, the underlying etiology could not be attributed. Over two-thirds (69.9%) of vision loss was potentially avoidable in nature. This study explored the causes of vision loss in Eritrean children using hospital based data. Cataract corneal opacities, refractive error and amblyopia, globe damage due to trauma, infection and nutritional deficiency, retinal disorders, and other congenital abnormalities were the leading causes of childhood vision impairment in children attending the tertiary eye hospital in Eritrea. As majority of the causes of vision loss was due to avoidable

  9. Grounding Our Vision: Brain Research and Strategic Vision

    ERIC Educational Resources Information Center

    Walker, Mike

    2011-01-01

    While recognizing the value of "vision," it could be argued that vision alone--at least in schools--is not enough to rally the financial and emotional support required to translate an idea into reality. A compelling vision needs to reflect substantive, research-based knowledge if it is to spark the kind of strategic thinking and insight…

  10. Design of verification platform for wireless vision sensor networks

    NASA Astrophysics Data System (ADS)

    Ye, Juanjuan; Shang, Fei; Yu, Chuang

    2017-08-01

    At present, the majority of research for wireless vision sensor networks (WVSNs) still remains in the software simulation stage, and the verification platforms of WVSNs that available for use are very few. This situation seriously restricts the transformation from theory research of WVSNs to practical application. Therefore, it is necessary to study the construction of verification platform of WVSNs. This paper combines wireless transceiver module, visual information acquisition module and power acquisition module, designs a high-performance wireless vision sensor node whose core is ARM11 microprocessor and selects AODV as the routing protocol to set up a verification platform called AdvanWorks for WVSNs. Experiments show that the AdvanWorks can successfully achieve functions of image acquisition, coding, wireless transmission, and obtain the effective distance parameters between nodes, which lays a good foundation for the follow-up application of WVSNs.

  11. Visual acuity, self-reported vision and falls in the EPIC-Norfolk Eye study.

    PubMed

    Yip, Jennifer L Y; Khawaja, Anthony P; Broadway, David; Luben, Robert; Hayat, Shabina; Dalzell, Nichola; Bhaniani, Amit; Wareham, Nicholas; Khaw, Kay-Tee; Foster, Paul J

    2014-03-01

    To examine the relationship between visual acuity (VA) and self-reported vision (SRV) in relation to falls in 8317 participants of the European Prospective Investigation into Cancer-Norfolk Eye study. All participants completed a health questionnaire that included a question regarding SRV and questions regarding the number of falls in the past year. Distance VA was measured using a logMAR chart for each eye. Poor SRV was defined as those reporting fair or poor distance vision. The relationship between VA and SRV and self-rated falls was analysed by logistic regression, adjusting for age, sex, physical activity, body mass index, chronic disease, medication use and grip strength. Of 8317 participants, 26.7% (95% CI 25.7% to 27.7%) had fallen in the past 12 months. Worse VA and poorer SRV were associated with one or more falls in multivariable analysis (OR for falls=1.31, 95% CI 1.04 to 1.66 and OR=1.32, 95% CI 1.09 to 1.61, respectively). Poorer SRV was significantly associated with falls even after adjusting for VA (OR=1.28, 95% CI 1.05 to 1.57). SRV was associated with falls independently of VA and could be used as a simple proxy measure for other aspects of visual function to detect people requiring vision-related falls interventions.

  12. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    PubMed

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  13. Spatial updating depends on gaze direction even after loss of vision.

    PubMed

    Reuschel, Johanna; Rösler, Frank; Henriques, Denise Y P; Fiehler, Katja

    2012-02-15

    Direction of gaze (eye angle + head angle) has been shown to be important for representing space for action, implying a crucial role of vision for spatial updating. However, blind people have no access to vision yet are able to perform goal-directed actions successfully. Here, we investigated the role of visual experience for localizing and updating targets as a function of intervening gaze shifts in humans. People who differed in visual experience (late blind, congenitally blind, or sighted) were briefly presented with a proprioceptive reach target while facing it. Before they reached to the target's remembered location, they turned their head toward an eccentric direction that also induced corresponding eye movements in sighted and late blind individuals. We found that reaching errors varied systematically as a function of shift in gaze direction only in participants with early visual experience (sighted and late blind). In the late blind, this effect was solely present in people with moveable eyes but not in people with at least one glass eye. Our results suggest that the effect of gaze shifts on spatial updating develops on the basis of visual experience early in life and remains even after loss of vision as long as feedback from the eyes and head is available.

  14. Optoelectronic stereoscopic device for diagnostics, treatment, and developing of binocular vision

    NASA Astrophysics Data System (ADS)

    Pautova, Larisa; Elkhov, Victor A.; Ovechkis, Yuri N.

    2003-08-01

    Operation of the device is based on alternative generation of pictures for left and right eyes on the monitor screen. Controller gives pulses on LCG so that shutter for left or right eye opens synchronously with pictures. The device provides frequency of switching more than 100 Hz, and that is why the flickering is absent. Thus, a separate demonstration of images to the left eye or to the right one in turn is obtained for patients being unaware and creates the conditions of binocular perception clsoe to natural ones without any additional separation of vision fields. LC-cell transfer characteristic coodination with time parameters of monitor screen has enabled to improve stereo image quality. Complicated problem of computer stereo images with LC-glasses is so called 'ghosts' - noise images that come to blocked eye. We reduced its influence by adapting stereo images to phosphor and LC-cells characteristics. The device is intended for diagnostics and treatment of stabismus, amblyopia and other binocular and stereoscopic vision impairments, for cultivating, training and developing of stereoscopic vision, for measurements of horizontal and vertical phoria, phusion reserves, the stereovision acuity and some else, for fixing central scotoma borders, as well as suppression scotoma in strabismus too.

  15. Development of VIPER: a simulator for assessing vision performance of warfighters

    NASA Astrophysics Data System (ADS)

    Familoni, Jide; Thompson, Roger; Moyer, Steve; Mueller, Gregory; Williams, Tim; Nguyen, Hung-Quang; Espinola, Richard L.; Sia, Rose K.; Ryan, Denise S.; Rivers, Bruce A.

    2016-05-01

    Background: When evaluating vision, it is important to assess not just the ability to read letters on a vision chart, but also how well one sees in real life scenarios. As part of the Warfighter Refractive Eye Surgery Program (WRESP), visual outcomes are assessed before and after refractive surgery. A Warfighter's ability to read signs and detect and identify objects is crucial, not only when deployed in a military setting, but also in their civilian lives. Objective: VIPER, a VIsion PERformance simulator was envisioned as actual video-based simulated driving to test warfighters' functional vision under realistic conditions. Designed to use interactive video image controlled environments at daytime, dusk, night, and with thermal imaging vision, it simulates the experience of viewing and identifying road signs and other objects while driving. We hypothesize that VIPER will facilitate efficient and quantifiable assessment of changes in vision and measurement of functional military performance. Study Design: Video images were recorded on an isolated 1.1 mile stretch of road with separate target sets of six simulated road signs and six objects of military interest, separately. The video footage were integrated with customdesigned C++ based software that presented the simulated drive to an observer on a computer monitor at 10, 20 or 30 miles/hour. VIPER permits the observer to indicate when a target is seen and when it is identified. Distances at which the observer recognizes and identifies targets are automatically logged. Errors in recognition and identification are also recorded. This first report describes VIPER's development and a preliminary study to establish a baseline for its performance. In the study, nine soldiers viewed simulations at 10 miles/hour and 30 miles/hour, run in randomized order for each participant seated at 36 inches from the monitor. Relevance: Ultimately, patients are interested in how their vision will affect their ability to perform daily

  16. Vision correction via multi-layer pattern corneal surgery

    NASA Astrophysics Data System (ADS)

    Sun, Han-Yin; Wang, Hsiang-Chen; Yang, Shun-Fa

    2013-07-01

    With the rapid development of vision correction techniques, increasing numbers of people have undergone laser vision corrective surgery in recent years. The use of a laser scalpel instead of a traditional surgical knife reduces the size of the wound and quickens recovery after surgery. The primary objective of this article is to examine corneal surgery for vision correction via multi-layer swim-ring-shaped wave circles of the technique through optical simulations with the use of Monte-Carlo ray tracing method. Presbyopia stems from the loss of flexibility of crystalline lens due to aging of the eyeball. Diopter adjustment of a normal crystalline lens could reach 5 D; in the case of presbyopia, the adjustment was approximately 1 D, which made patients unable to see objects clearly in near distance. Corneal laser surgery with multi-layer swim-ring-shaped wave circles was performed, which ablated multiple circles on the cornea to improve flexibility of the crystalline lens. Simulation results showed that the ability of the crystalline lens to adjust increased tremendously from 1 D to 4 D. The method was also used to compare the images displayed on the retina before and after the treatment. The results clearly indicated a significant improvement in presbyopia symptoms with the use of this technique.

  17. Chromatic correction for a VIS-SWIR zoom lens using optical glasses

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Williams, Daniel J. L.; McCarthy, Peter; Visconti, Anthony J.; Bentley, Julie L.; Moore, Duncan T.

    2015-09-01

    With the advancement in sensors, hyperspectral imaging in short wave infrared (SWIR 0.9 μm to 1.7 μm) now has wide applications, including night vision, haze-penetrating imaging, etc. Most conventional optical glasses can be material candidates for designing in the SWIR as they transmit up to 2.2 μm. However, since SWIR is in the middle of the glasses' major absorption wavebands in UV and IR, the flint glasses in SWIR are less dispersive than in the visible spectrum. As a result, the glass map in the SWIR is highly compressed, with crowns and flints all clustering together. Thus correcting for chromatic aberration is more challenging in the SWIR, since the Abbé number ratio of the same glass combination is reduced. Conventionally, fluorides, such as CaF2 and BaF2, are widely used in designing SWIR system due to their unique dispersion properties, even though they are notorious for poor manufacturability or even high toxicity. For lens elements in a zoom system, the ray bundle samples different sections of the each lens aperture as the lens zooms. This creates extra uncertainty in correcting chromatic aberrations. This paper focuses on using only commercially available optical glasses to color-correct a 3X dual-band zoom lens system in the VIS-SWIR. The design tools and techniques are detailed in terms of material selections to minimize the chromatic aberrations in such a large spectrum band and all zoom positions. Examples are discussed for designs with different aperture stop locations, which considerably affect the material choices.

  18. Distance-near disparity esotropia: can we shrink the gap?

    PubMed

    Burke, J P

    2015-02-01

    Distance-near disparity esotropias are a group of heterogenous usually acquired strabismus disorders, where the angle of misalignment at near exceeds that at distance by 10 prism diopters or more, where the accurate correction of refractive errors and ambylopia are important early objectives. These aetiologically diverse entities respond non-uniformally to strabismus surgery and bifocals. The management challenge is one of 'shrinking' the disparity so that the affected individuals can develop and comfortably maintain binocular single vision and/or optimal alignment. Surgical procedures have continued to evolve but none of the current operative procedures are superior for all patients. Subclassifying this strabismus and highlighting publication data from more homogenous clinical series may assist with the optimisation of future management and treatment outcomes.

  19. Use of market segmentation to identify untapped consumer needs in vision correction surgery for future growth.

    PubMed

    Loarie, Thomas M; Applegate, David; Kuenne, Christopher B; Choi, Lawrence J; Horowitz, Diane P

    2003-01-01

    Market segmentation analysis identifies discrete segments of the population whose beliefs are consistent with exhibited behaviors such as purchase choice. This study applies market segmentation analysis to low myopes (-1 to -3 D with less than 1 D cylinder) in their consideration and choice of a refractive surgery procedure to discover opportunities within the market. A quantitative survey based on focus group research was sent to a demographically balanced sample of myopes using contact lenses and/or glasses. A variable reduction process followed by a clustering analysis was used to discover discrete belief-based segments. The resulting segments were validated both analytically and through in-market testing. Discontented individuals who wear contact lenses are the primary target for vision correction surgery. However, 81% of the target group is apprehensive about laser in situ keratomileusis (LASIK). They are nervous about the procedure and strongly desire reversibility and exchangeability. There exists a large untapped opportunity for vision correction surgery within the low myope population. Market segmentation analysis helped determine how to best meet this opportunity through repositioning existing procedures or developing new vision correction technology, and could also be applied to identify opportunities in other vision correction populations.

  20. Making a vision document tangible using "vision-tactics-metrics" tables.

    PubMed

    Drury, Ivo; Slomski, Carol

    2006-01-01

    We describe a method of making a vision document tangible by attaching specific tactics and metrics to the key elements of the vision. We report on the development and early use of a "vision-tactics-metrics" table in a department of surgery. Use of the table centered the vision in the daily life of the department and its faculty, and facilitated cultural change.

  1. Power profiles of single vision and multifocal soft contact lenses.

    PubMed

    Wagner, Sandra; Conrad, Fabian; Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Holden, Brien A

    2015-02-01

    The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression. The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated. Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality. Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Three-camera stereo vision for intelligent transportation systems

    NASA Astrophysics Data System (ADS)

    Bergendahl, Jason; Masaki, Ichiro; Horn, Berthold K. P.

    1997-02-01

    A major obstacle in the application of stereo vision to intelligent transportation system is high computational cost. In this paper, a PC based three-camera stereo vision system constructed with off-the-shelf components is described. The system serves as a tool for developing and testing robust algorithms which approach real-time performance. We present an edge based, subpixel stereo algorithm which is adapted to permit accurate distance measurements to objects in the field of view using a compact camera assembly. Once computed, the 3D scene information may be directly applied to a number of in-vehicle applications, such as adaptive cruise control, obstacle detection, and lane tracking. Moreover, since the largest computational costs is incurred in generating the 3D scene information, multiple applications that leverage this information can be implemented in a single system with minimal cost. On-road applications, such as vehicle counting and incident detection, are also possible. Preliminary in-vehicle road trial results are presented.

  3. Survey and research on up-conversion emission character and energy transition of Yb3+/Er3+/Tm3+ co-doped phosphate glass and glass ceramic

    NASA Astrophysics Data System (ADS)

    Yu, Yin; Song, Feng; Ming, Chengguo; Liu, Jiadong; Li, Wei; Liu, Yanling; Zhao, Hongyan

    2012-11-01

    By conventional high-temperature melting method, Yb3+/Er3+/Tm3+ co-doped phosphate glass was synthesized. After annealing the precursor glass, the phosphate glass ceramic (GC) was obtained. By measuring the X-ray diffraction (XRD) spectrum, it is proved that the LiYbP4O12 and Li6P6O18 nano-crystals have existed in the phosphate GC. The up-conversion (UC) emission intensity of the GC is obvious stronger compared to that of the glass. The reason is that the shorter distance between rare earth ions in the glass ceramic increases the energy transitions from the sensitized ions (Yb3+) to the luminous ions (Er3+ and Tm3+). By studying the dependence of UC emissions on the pump power, the 523 and 546 nm green emissions of Er3+ ions in the glass are two-photon processes. But in the glass ceramic, they are two/three-photon processes. The phenomenon implies that a three-photon process has participated in the population of the two green emissions. Using Dexter theory, we discuss the energy transitions of Er3+ and Tm3+. The results indicate the energy transition of Tm3+ to Er3+ is very strong in the GC, which changes the population mechanism of UC emissions of Er3+.

  4. Influence of Socially Used Drugs on Vision and Vision Performance

    DTIC Science & Technology

    1974-07-31

    AD-A012 909 INFLUENCE OF SOCIALLY USED DRUGS ON VISION AND VISION PERFORMANCE OPTICAL SCIENCES GROUP PREPARED FOR ARMY MEDICAL RESEARCH AND...AND ADDRESS 12. REPORT DATE July 11, 1974 U.S. Army Medical Research and D mvelopmenteommand 13. NUMBER OF PAGES Washington, D.C. 203114 14...nreeeoary and identily by block number) vision vision performance alcohol marijuana tetrahydrocannabinol 20. ABSTRACT (Continue on reverae aide It

  5. Tunnel vision: sharper gradient of spatial attention in autism.

    PubMed

    Robertson, Caroline E; Kravitz, Dwight J; Freyberg, Jan; Baron-Cohen, Simon; Baker, Chris I

    2013-04-17

    Enhanced perception of detail has long been regarded a hallmark of autism spectrum conditions (ASC), but its origins are unknown. Normal sensitivity on all fundamental perceptual measures-visual acuity, contrast discrimination, and flicker detection-is strongly established in the literature. If individuals with ASC do not have superior low-level vision, how is perception of detail enhanced? We argue that this apparent paradox can be resolved by considering visual attention, which is known to enhance basic visual sensitivity, resulting in greater acuity and lower contrast thresholds. Here, we demonstrate that the focus of attention and concomitant enhancement of perception are sharper in human individuals with ASC than in matched controls. Using a simple visual acuity task embedded in a standard cueing paradigm, we mapped the spatial and temporal gradients of attentional enhancement by varying the distance and onset time of visual targets relative to an exogenous cue, which obligatorily captures attention. Individuals with ASC demonstrated a greater fall-off in performance with distance from the cue than controls, indicating a sharper spatial gradient of attention. Further, this sharpness was highly correlated with the severity of autistic symptoms in ASC, as well as autistic traits across both ASC and control groups. These findings establish the presence of a form of "tunnel vision" in ASC, with far-reaching implications for our understanding of the social and neurobiological aspects of autism.

  6. Rethinking ADA signage standards for low-vision accessibility.

    PubMed

    Arditi, Aries

    2017-05-01

    Americans With Disabilities Act (ADA) and International Code Council (ICC) standards for accessible buildings and facilities affect design and construction of all new and renovated buildings throughout the United States, and form the basis for compliance with the ADA. While these standards may result in acceptable accessibility for people who are fully blind, they fall far short of what they could and should accomplish for those with low vision. In this article I critique the standards, detailing their lack of evidence base and other shortcomings. I suggest that simply making existing requirements stricter (e.g., by mandating larger letter size or higher contrasts) will not ensure visual accessibility and therefore cannot act as a valid basis for compliance with the law. I propose two remedies. First, requirements for visual characteristics of signs intended to improve access for those with low vision should be expressed not in terms of physical features, such as character height and contrast, but rather in terms of the distance at which a sign can be read by someone with nominally normal (20/20) visual acuity under expected lighting conditions for the installed environment. This would give sign designers greater choice in design parameters but place on them the burden of ensuring legibility. Second, mounting of directional signs, which are critical for effective and efficient wayfinding, should be required to be in consistent and approachable locations so that those with reduced acuity may view them at close distance.

  7. Rethinking ADA signage standards for low-vision accessibility

    PubMed Central

    Arditi, Aries

    2017-01-01

    Americans With Disabilities Act (ADA) and International Code Council (ICC) standards for accessible buildings and facilities affect design and construction of all new and renovated buildings throughout the United States, and form the basis for compliance with the ADA. While these standards may result in acceptable accessibility for people who are fully blind, they fall far short of what they could and should accomplish for those with low vision. In this article I critique the standards, detailing their lack of evidence base and other shortcomings. I suggest that simply making existing requirements stricter (e.g., by mandating larger letter size or higher contrasts) will not ensure visual accessibility and therefore cannot act as a valid basis for compliance with the law. I propose two remedies. First, requirements for visual characteristics of signs intended to improve access for those with low vision should be expressed not in terms of physical features, such as character height and contrast, but rather in terms of the distance at which a sign can be read by someone with nominally normal (20/20) visual acuity under expected lighting conditions for the installed environment. This would give sign designers greater choice in design parameters but place on them the burden of ensuring legibility. Second, mounting of directional signs, which are critical for effective and efficient wayfinding, should be required to be in consistent and approachable locations so that those with reduced acuity may view them at close distance. PMID:28510625

  8. Self-sensing E-glass-fiber-reinforced composites

    NASA Astrophysics Data System (ADS)

    Brooks, David; Hayes, Simon A.; Khan, N. A.; Zolfaghar, K.; Fernando, Gerard F.

    1997-06-01

    Conventional E-glass fibers were surface treated to enable them to act as light guides for short distances. The reinforcing fiber light guides were embedded in glass fiber reinforced epoxy prepregs and processed into composites. The resultant composite was termed the self-sensing composite as any damage to these fibers or its interface would result in the attenuation of the transmitted light. Epoxy, silicone, fluoropolymer and sol-gel derived cladding materials were evaluated as potential cladding materials. RFLGs with a silicone coating was found to give the best light transmission. The self-sensing fibers were capable of detecting a 0.5 J direct impact. The feasibility of using the RFLGs for impact damage location was also demonstrated successfully as bleeding-light could be seen in the vicinity of the impact.

  9. A cognitive approach to vision for a mobile robot

    NASA Astrophysics Data System (ADS)

    Benjamin, D. Paul; Funk, Christopher; Lyons, Damian

    2013-05-01

    We describe a cognitive vision system for a mobile robot. This system works in a manner similar to the human vision system, using saccadic, vergence and pursuit movements to extract information from visual input. At each fixation, the system builds a 3D model of a small region, combining information about distance, shape, texture and motion. These 3D models are embedded within an overall 3D model of the robot's environment. This approach turns the computer vision problem into a search problem, with the goal of constructing a physically realistic model of the entire environment. At each step, the vision system selects a point in the visual input to focus on. The distance, shape, texture and motion information are computed in a small region and used to build a mesh in a 3D virtual world. Background knowledge is used to extend this structure as appropriate, e.g. if a patch of wall is seen, it is hypothesized to be part of a large wall and the entire wall is created in the virtual world, or if part of an object is recognized, the whole object's mesh is retrieved from the library of objects and placed into the virtual world. The difference between the input from the real camera and from the virtual camera is compared using local Gaussians, creating an error mask that indicates the main differences between them. This is then used to select the next points to focus on. This approach permits us to use very expensive algorithms on small localities, thus generating very accurate models. It also is task-oriented, permitting the robot to use its knowledge about its task and goals to decide which parts of the environment need to be examined. The software components of this architecture include PhysX for the 3D virtual world, OpenCV and the Point Cloud Library for visual processing, and the Soar cognitive architecture, which controls the perceptual processing and robot planning. The hardware is a custom-built pan-tilt stereo color camera. We describe experiments using both

  10. Validity of the Worth 4 Dot Test in Patients with Red-Green Color Vision Defect.

    PubMed

    Bak, Eunoo; Yang, Hee Kyung; Hwang, Jeong-Min

    2017-05-01

    The Worth four dot test uses red and green glasses for binocular dissociation, and although it has been believed that patients with red-green color vision defects cannot accurately perform the Worth four dot test, this has not been validated. Therefore, the purpose of this study was to demonstrate the validity of the Worth four dot test in patients with congenital red-green color vision defects who have normal or abnormal binocular vision. A retrospective review of medical records was performed on 30 consecutive congenital red-green color vision defect patients who underwent the Worth four dot test. The type of color vision anomaly was determined by the Hardy Rand and Rittler (HRR) pseudoisochromatic plate test, Ishihara color test, anomaloscope, and/or the 100 hue test. All patients underwent a complete ophthalmologic examination. Binocular sensory status was evaluated with the Worth four dot test and Randot stereotest. The results were interpreted according to the presence of strabismus or amblyopia. Among the 30 patients, 24 had normal visual acuity without strabismus nor amblyopia and 6 patients had strabismus and/or amblyopia. The 24 patients without strabismus nor amblyopia all showed binocular fusional responses by seeing four dots of the Worth four dot test. Meanwhile, the six patients with strabismus or amblyopia showed various results of fusion, suppression, and diplopia. Congenital red-green color vision defect patients of different types and variable degree of binocularity could successfully perform the Worth four dot test. They showed reliable results that were in accordance with their estimated binocular sensory status.

  11. Patient-reported benefit of ReSTOR multi-focal intraocular lenses after cataract surgery: results of principal component analysis on clinical trial data.

    PubMed

    Berdeaux, Gilles; Viala, Muriel; Roborel de Climens, Aude; Arnould, Benoit

    2008-01-24

    Restoration of functional distance and near vision independently of additional correction remains a goal for cataract surgery. ReSTOR, a new multi-focal intraocular lens (IOL) addresses this issue with an improvement in both distance and near vision, often without need for glasses. This analysis attempted to discuss the patient-reported benefit of ReSTOR using a full but organised representation of data. Two non-randomised, open-label clinical trials conducted in Europe and the United-States were conducted to compare the efficacy of ReSTOR to AcrySof mono-focal IOLs. A total of 710 patients in need of bilateral cataract extraction were included in the pooled study. The TyPE, a patient questionnaire, was fully completed by 672 of them before and after each eye surgery. The TyPE, composed of 67 items measuring overall visual functioning in both conditions (with and without wearing glasses), evaluates limitations, troubles and satisfaction in distance and near vision. A principal component analysis (PCA) of the TyPE questionnaire was performed on pooled data from baseline and post-surgery observations in order to fully represent the change in the TyPE data over time. ReSTOR and mono-focal groups were used as illustrative variables. The coordinates of the first 2 factors were compared between visits and between IOLs (ReSTOR vs. mono-focal), using paired t-tests and t-tests, respectively. The first factor of the PCA explained 55% of the variance and represented 'visual functioning and patient satisfaction'. The second factor explained 6% of the variance and was interpreted as 'independence from glasses'. An overall difference in factorial coordinates in both factors was seen between baseline and the first eye surgery, and between the first and the second eye surgery. No difference between ReSTOR and mono-focal IOL groups was observed at baseline. After surgery, ReSTOR treated-patients had higher coordinates on both "visual functioning and satisfaction" and "independence

  12. The disparate histories of binocular vision and binaural hearing.

    PubMed

    Wade, Nicholas J

    2018-01-01

    Vision and hearing are dependent on disparities of spatial patterns received by two eyes and on time and intensity differences to two ears. However, the experiences of a single world have masked attention to these disparities. While eyes and ears are paired, there has not been parity in the attention directed to their functioning. Phenomena involving binocular vision were commented upon since antiquity whereas those about binaural hearing are much more recent. This history is compared with respect to the experimental manipulations of dichoptic and dichotic stimuli and the instruments used to stimulate the paired organs. Binocular color mixing led to studies of binaural hearing and direction and distance in visual localization were analyzed before those for auditory localization. Experimental investigations began in the nineteenth century with the invention of instruments like the stereoscope and pseudoscope, soon to be followed by their binaural equivalents, the stethophone and pseudophone.

  13. Experimental Study of the Impact Damage on AN Al2O3-COATED Glass Under Stress

    NASA Astrophysics Data System (ADS)

    Suh, Chang-Min; Kim, Sung-Ho; Suh, Duck-Young

    The impact damage of an Al2O3-coated soda-lime glass under tensile and compressive stress conditions was investigated by an impact test using a steel ball (2mm dia.). The size of the glass specimens was 40×40×5(mm). In order to change the porosity percent of each specimen, the target distance was set at 120mm and 70mm. Also, the effect of the thickness of the coating layer was shown by two amounts (100 μm and 50 μm). The velocity of the steel balls was set between 30 and 60m/s. After the impact test, the crack patterns and lengths were measured using a stereo-microscope. The tensile and compressive specimens were prepared by inflation and deflation of air pressure within a pressure vessel. It was confirmed that the crack length of the glass under tensile stress was longer than that of glass under compressive stress. Also, the optimum conditions were a target distance of 70mm and 100 μm of a coating thickness, thus resulting in a minimization of porosity percent and area.

  14. Colour vision deficiency.

    PubMed

    Simunovic, M P

    2010-05-01

    Colour vision deficiency is one of the commonest disorders of vision and can be divided into congenital and acquired forms. Congenital colour vision deficiency affects as many as 8% of males and 0.5% of females--the difference in prevalence reflects the fact that the commonest forms of congenital colour vision deficiency are inherited in an X-linked recessive manner. Until relatively recently, our understanding of the pathophysiological basis of colour vision deficiency largely rested on behavioural data; however, modern molecular genetic techniques have helped to elucidate its mechanisms. The current management of congenital colour vision deficiency lies chiefly in appropriate counselling (including career counselling). Although visual aids may be of benefit to those with colour vision deficiency when performing certain tasks, the evidence suggests that they do not enable wearers to obtain normal colour discrimination. In the future, gene therapy remains a possibility, with animal models demonstrating amelioration following treatment.

  15. Structure and properties of strontium-doped phosphate-based glasses

    PubMed Central

    Abou Neel, Ensanya A.; Chrzanowski, Wojciech; Pickup, David M.; O'Dell, Luke A.; Mordan, Nicola J.; Newport, Robert J.; Smith, Mark E.; Knowles, Jonathan C.

    2008-01-01

    Owing to similarity in both ionic size and polarity, strontium (Sr2+) is known to behave in a comparable way to calcium (Ca2+), and its role in bone metabolism has been well documented as both anti-resorptive and bone forming. In this study, novel quaternary strontium-doped phosphate-based glasses, containing 1, 3 and 5 mol% SrO, were synthesized and characterized. 31P magic angle spinning (MAS) nuclear magnetic resonance results showed that, as the Sr2+ content is increased in the glasses, there is a slight increase in disproportionation of Q2 phosphorus environments into Q1 and Q3 environments. Moreover, shortening and strengthening of the phosphorus to bridging oxygen distance occurred as obtained from FTIR. The general broadening of the spectral features with Sr2+ content is most probably due to the increased variation of the phosphate–cation bonding interactions caused by the introduction of the third cation. This increased disorder may be the cause of the increased degradation of the Sr-containing glasses relative to the Sr-free glass. As confirmed from elemental analysis, all Sr-containing glasses showed higher Na2O than expected and this also could be accounted for by the higher degradation of these glasses compared with Sr-free glasses. Measurements of surface free energy (SFE) showed that incorporation of strontium had no effect on SFE, and samples had relatively higher fractional polarity, which is not expected to promote high cell activity. From viability studies, however, the incorporation of Sr2+ showed better cellular response than Sr2+-free glasses, but still lower than the positive control. This unfavourable cellular response could be due to the high degradation nature of these glasses and not due to the presence of Sr2+. PMID:18826914

  16. Vision Screening for Children 36 to <72 Months: Recommended Practices

    PubMed Central

    Cotter, Susan A.; Cyert, Lynn A.; Miller, Joseph M.; Quinn, Graham E.

    2015-01-01

    ABSTRACT Purpose This article provides recommendations for screening children aged 36 to younger than 72 months for eye and visual system disorders. The recommendations were developed by the National Expert Panel to the National Center for Children’s Vision and Eye Health, sponsored by Prevent Blindness, and funded by the Maternal and Child Health Bureau of the Health Resources and Services Administration, United States Department of Health and Human Services. The recommendations describe both best and acceptable practice standards. Targeted vision disorders for screening are primarily amblyopia, strabismus, significant refractive error, and associated risk factors. The recommended screening tests are intended for use by lay screeners, nurses, and other personnel who screen children in educational, community, public health, or primary health care settings. Characteristics of children who should be examined by an optometrist or ophthalmologist rather than undergo vision screening are also described. Results There are two current best practice vision screening methods for children aged 36 to younger than 72 months: (1) monocular visual acuity testing using single HOTV letters or LEA Symbols surrounded by crowding bars at a 5-ft (1.5 m) test distance, with the child responding by either matching or naming, or (2) instrument-based testing using the Retinomax autorefractor or the SureSight Vision Screener with the Vision in Preschoolers Study data software installed (version 2.24 or 2.25 set to minus cylinder form). Using the Plusoptix Photoscreener is acceptable practice, as is adding stereoacuity testing using the PASS (Preschool Assessment of Stereopsis with a Smile) stereotest as a supplemental procedure to visual acuity testing or autorefraction. Conclusions The National Expert Panel recommends that children aged 36 to younger than 72 months be screened annually (best practice) or at least once (accepted minimum standard) using one of the best practice approaches

  17. An Rx for 20/20 Vision: Vision Planning and Education.

    ERIC Educational Resources Information Center

    Chrisman, Gerald J.; Holliday, Clifford R.

    1996-01-01

    Discusses the Dallas Independent School District's decision to adopt an integrated technology infrastructure and the importance of vision planning for long term goals. Outlines the vision planning process: first draft; environmental projection; restatement of vision in terms of market projections, anticipated customer needs, suspected competitor…

  18. Vision Therapy News Backgrounder.

    ERIC Educational Resources Information Center

    American Optometric Association, St. Louis, MO.

    The booklet provides an overview on vision therapy to aid writers, editors, and broadcasters help parents, teachers, older adults, and all consumers learn more about vision therapy. Following a description of vision therapy or vision training, information is provided on how and why vision therapy works. Additional sections address providers of…

  19. Perceived vision-related quality of life and risk of falling among community living elderly people.

    PubMed

    Källstrand-Eriksson, Jeanette; Baigi, Amir; Buer, Nina; Hildingh, Cathrine

    2013-06-01

    Falls and fall injuries among the elderly population are common, since ageing is a risk factor of falling. Today, this is a major problem because the ageing population is increasing. There are predictive factors of falling and visual impairment is one of them. Usually, only visual acuity is considered when measuring visual impairment, and nothing regarding a person's functional visual ability is taken into account. Therefore, the aim of this study was to assess the perceived vision-related quality of life among the community living elderly using the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) and to investigate whether there was any association among vision-related quality of life and falls. There were 212 randomly selected elderly people participating in the study. Our study indicated that the participants had an impaired perceived vision-related health status. General health was the only NEI VFQ-25 variable significantly associated with falls in both men and women. However, among men, near and distance activities, vision-specific social functioning, role difficulties and dependency, color and peripheral vision were related to falls. © 2012 Nordic College of Caring Science.

  20. Comparison of Artificial Immune System and Particle Swarm Optimization Techniques for Error Optimization of Machine Vision Based Tool Movements

    NASA Astrophysics Data System (ADS)

    Mahapatra, Prasant Kumar; Sethi, Spardha; Kumar, Amod

    2015-10-01

    In conventional tool positioning technique, sensors embedded in the motion stages provide the accurate tool position information. In this paper, a machine vision based system and image processing technique for motion measurement of lathe tool from two-dimensional sequential images captured using charge coupled device camera having a resolution of 250 microns has been described. An algorithm was developed to calculate the observed distance travelled by the tool from the captured images. As expected, error was observed in the value of the distance traversed by the tool calculated from these images. Optimization of errors due to machine vision system, calibration, environmental factors, etc. in lathe tool movement was carried out using two soft computing techniques, namely, artificial immune system (AIS) and particle swarm optimization (PSO). The results show better capability of AIS over PSO.

  1. Color vision test

    MedlinePlus

    ... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...

  2. Vision Status in Older Adults: The Brazilian Amazon Region Eye Survey.

    PubMed

    Salomão, Solange R; Berezovsky, Adriana; Furtado, João M; Fernandes, Arthur G; Muñoz, Sergio; Cavascan, Nívea N; Cypel, Marcela C; Cunha, Cristina C; Vasconcelos, Galton C; Mitsuhiro, Márcia R K H; Sacai, Paula Y; Campos, Mauro; Morales, Paulo H A; Cohen, Marcos J; Cohen, Jacob M; Watanabe, Sung E S; Belfort, Rubens

    2018-01-17

    Older adults living in remote areas with limited access to health services are at higher risk to develop visual impairment and blindness. We conducted a population-based survey to determine the vision status in subjects 45 years of age and older from urban and rural areas of Parintins city, Brazilian Amazon Region. Participants underwent ophthalmic examination, including uncorrected (UCVA), presenting (PVA) and best-corrected visual acuity (BCVA). Vision status was described as lines of visual acuity (VA) impairment and lines of VA improvement from UCVA to BCVA and from PVA to BCVA in the better-seeing eye. A total of 2384 subjects were enumerated, 2041 (85.6%) were examined, with reliable VA measurements obtained from 2025 participants. Vision status in lines of VA impairment was (mean ± standard deviation): 3.44 ± 3.53 for UCVA, 2.85 ± 3.52 for PVA and 1.50 ± 3.51 for BCVA. Female gender, older age and lower education were associated with ≥6 lines of UCVA impairment. Lines of improvement ≥3 was found in 626 (30.9%) participants and associated with female gender and rural residency. In conclusion, a third of participants could have at least three lines of VA improvement with proper refraction. Strategies to improve access to eye care and affordable glasses are needed.

  3. Data fusion for a vision-aided radiological detection system: Calibration algorithm performance

    NASA Astrophysics Data System (ADS)

    Stadnikia, Kelsey; Henderson, Kristofer; Martin, Allan; Riley, Phillip; Koppal, Sanjeev; Enqvist, Andreas

    2018-05-01

    In order to improve the ability to detect, locate, track and identify nuclear/radiological threats, the University of Florida nuclear detection community has teamed up with the 3D vision community to collaborate on a low cost data fusion system. The key is to develop an algorithm to fuse the data from multiple radiological and 3D vision sensors as one system. The system under development at the University of Florida is being assessed with various types of radiological detectors and widely available visual sensors. A series of experiments were devised utilizing two EJ-309 liquid organic scintillation detectors (one primary and one secondary), a Microsoft Kinect for Windows v2 sensor and a Velodyne HDL-32E High Definition LiDAR Sensor which is a highly sensitive vision sensor primarily used to generate data for self-driving cars. Each experiment consisted of 27 static measurements of a source arranged in a cube with three different distances in each dimension. The source used was Cf-252. The calibration algorithm developed is utilized to calibrate the relative 3D-location of the two different types of sensors without need to measure it by hand; thus, preventing operator manipulation and human errors. The algorithm can also account for the facility dependent deviation from ideal data fusion correlation. Use of the vision sensor to determine the location of a sensor would also limit the possible locations and it does not allow for room dependence (facility dependent deviation) to generate a detector pseudo-location to be used for data analysis later. Using manually measured source location data, our algorithm-predicted the offset detector location within an average of 20 cm calibration-difference to its actual location. Calibration-difference is the Euclidean distance from the algorithm predicted detector location to the measured detector location. The Kinect vision sensor data produced an average calibration-difference of 35 cm and the HDL-32E produced an average

  4. Silica coating on alumina ceramic: comparison of three chairside air-abrasion devices working for different times and distances.

    PubMed

    Pestana Passos, S; Dias Vanderlei, A; Ozcan, M; Felipe Valandro, L F; Felipe Valandro, L

    2011-03-01

    This study evaluated, by scanning electron microscope (SEM) and EDS, the effect of different strategies for silica coating (sandblasters, time and distance) of a glass-infiltrated ceramic (In-Ceram Alumina). Forty-one ceramic blocks were produced. For comparison of the three air-abrasion devices, 15 ceramic samples were divided in three groups (N.=5): Bioart, Microetcher and Ronvig (air-abrasion parameters: 20 s at a distance of 10 mm). For evaluation of the time and distance factors, ceramic samples (N.=5) were allocated in groups considering three applied times (5 s, 13 s and 20 s) and two distances (10 mm and 20 mm), using the Ronvig device. In a control sample, no surface treatment was performed. After that, the micro-morphologic analyzes of the ceramic surfaces were made using SEM. EDS analyzes were carried out to detect the % of silica on representative ceramic surface. ANOVA and Tukey tests were used to analyze the results. One-way ANOVA showed the silica deposition was different for different devices (P=0.0054). The Ronvig device promoted the highest silica coating compared to the other devices (Tukey test). Two-way ANOVA showed the distance and time factors did not affect significantly the silica deposition (application time and distance showed no statistical difference). The Ronvig device provided the most effective silica deposition on glass-infiltrated alumina ceramic surface and the studied time and distance for air-abrasion did not affect the silica coating.

  5. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    PubMed

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  6. Blindness and vision loss

    MedlinePlus

    ... eye ( chemical burns or sports injuries) Diabetes Glaucoma Macular degeneration The type of partial vision loss may differ, ... tunnel vision and missing areas of vision With macular degeneration, the side vision is normal but the central ...

  7. Robot Vision Library

    NASA Technical Reports Server (NTRS)

    Howard, Andrew B.; Ansar, Adnan I.; Litwin, Todd E.; Goldberg, Steven B.

    2009-01-01

    The JPL Robot Vision Library (JPLV) provides real-time robot vision algorithms for developers who are not vision specialists. The package includes algorithms for stereo ranging, visual odometry and unsurveyed camera calibration, and has unique support for very wideangle lenses

  8. Vision impairment and major causes of vision loss impacts on vision-specific functioning independent of socioeconomic factors.

    PubMed

    Chiang, Peggy P C; Zheng, Yingfeng; Wong, Tien Y; Lamoureux, Ecosse L

    2013-02-01

    To quantify the eye disease-specific impact of unilateral and bilateral vision impairment (VI) on vision-specific functioning (VF). The Singapore Indian Eye population-based study. Ethnic Indians older than 40 years of age living in Singapore. Participants underwent standardized ophthalmic assessments for VI and blindness, defined using presenting visual acuity (United States definition). Sociodemographic data were recorded using a standardized questionnaire. Rasch analysis was used to validate the Visual Function Index 11 and to determine its psychometric properties. The major causes of VI (i.e., cataract, refractive error, age-related macular degeneration, diabetic retinopathy [DR], and glaucoma) were determined by ophthalmologists on examination. Multivariate linear regression analysis was performed to assess the impact of VI on the overall VF Rasch score. Vision-specific functioning. Three thousand three hundred ninety-six persons were analyzed. Participants with VI had a systematic reduction in VF score compared with those with normal vision in both eyes, ranging from -11.2% normal vision in one eye and low vision in the other eye (95% confidence interval [CI], -12.2% to -10.3%; P<0.001), to -12.7% blindness in one eye and normal vision in the other eye (CI, -15.1% to -10.4%; P<0.001), to -19.4% low vision in both eyes (CI, -20.8% to -18.1%; P<0.001), to -52.9% blindness in one eye and low vision in other eye (CI, -55.3% to -50.4%; P<0.001), to -77.2% blindness in both eyes (CI, -82.4% to 72.0%; P<0.001). The impact of VI on VF score varied across different major causes of vision loss, regardless of socioeconomic factors. Vision impairment attributed to cataract in one or both eyes had a significant decrease in VF score by 17.7% and 22.3%, respectively, compared with those with normal vision in both eyes (P<0.001). The impact of unilateral and bilateral VI on VF score was greater in participants with glaucoma (32.2% in unilateral cases and 35.9% in bilateral

  9. How to assess vision.

    PubMed

    Marsden, Janet

    2016-09-21

    Rationale and key points An objective assessment of the patient's vision is important to assess variation from 'normal' vision in acute and community settings, to establish a baseline before examination and treatment in the emergency department, and to assess any changes during ophthalmic outpatient appointments. » Vision is one of the essential senses that permits people to make sense of the world. » Visual assessment does not only involve measuring central visual acuity, it also involves assessing the consequences of reduced vision. » Assessment of vision in children is crucial to identify issues that might affect vision and visual development, and to optimise lifelong vision. » Untreatable loss of vision is not an inevitable consequence of ageing. » Timely and repeated assessment of vision over life can reduce the incidence of falls, prevent injury and optimise independence. Reflective activity 'How to' articles can help update you practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How this article might change your practice when assessing people holistically. 2. How you could use this article to educate your colleagues in the assessment of vision.

  10. Device for diagnosis and treatment of impairments on binocular vision and stereopsis

    NASA Astrophysics Data System (ADS)

    Bahn, Jieun; Choi, Yong-Jin; Son, Jung-Young; Kodratiev, N. V.; Elkhov, Victor A.; Ovechkis, Yuri N.; Chung, Chan-sup

    2001-06-01

    Strabismus and amblyopia are two main impairments of our visual system, which are responsible for the loss of stereovision. A device is developed for diagnosis and treatment of strabismus and amblyopia, and for training and developing stereopsis. This device is composed of a liquid crystal glasses (LCG), electronics for driving LCG and synchronizing with an IBM PC, and a special software. The software contains specially designed patterns and graphics for enabling to train and develop stereopsis, and do objective measurement of some stereoscopic vision parameters such as horizontal and vertical phoria, fusion, fixation disparity, and stereoscopic visual threshold.

  11. Mathematical leadership vision.

    PubMed

    Hamburger, Y A

    2000-11-01

    This article is an analysis of a new type of leadership vision, the kind of vision that is becoming increasingly pervasive among leaders in the modern world. This vision appears to offer a new horizon, whereas, in fact it delivers to its target audience a finely tuned version of the already existing ambitions and aspirations of the target audience. The leader, with advisors, has examined the target audience and has used the results of extensive research and statistical methods concerning the group to form a picture of its members' lifestyles and values. On the basis of this information, the leader has built a "vision." The vision is intended to create an impression of a charismatic and transformational leader when, in fact, it is merely a response. The systemic, arithmetic, and statistical methods employed in this operation have led to the coining of the terms mathematical leader and mathematical vision.

  12. Single-mode glass waveguide technology for optical interchip communication on board level

    NASA Astrophysics Data System (ADS)

    Brusberg, Lars; Neitz, Marcel; Schröder, Henning

    2012-01-01

    The large bandwidth demand in long-distance telecom networks lead to single-mode fiber interconnects as result of low dispersion, low loss and dense wavelength multiplexing possibilities. In contrast, multi-mode interconnects are suitable for much shorter lengths up to 300 meters and are promising for optical links between racks and on board level. Active optical cables based on multi-mode fiber links are at the market and research in multi-mode waveguide integration on board level is still going on. Compared to multi-mode, a single-mode waveguide has much more integration potential because of core diameters of around 20% of a multi-mode waveguide by a much larger bandwidth. But light coupling in single-mode waveguides is much more challenging because of lower coupling tolerances. Together with the silicon photonics technology, a single-mode waveguide technology on board-level will be the straight forward development goal for chip-to-chip optical interconnects integration. Such a hybrid packaging platform providing 3D optical single-mode links bridges the gap between novel photonic integrated circuits and the glass fiber based long-distance telecom networks. Following we introduce our 3D photonic packaging approach based on thin glass substrates with planar integrated optical single-mode waveguides for fiber-to-chip and chip-to-chip interconnects. This novel packaging approach merges micro-system packaging and glass integrated optics. It consists of a thin glass substrate with planar integrated singlemode waveguide circuits, optical mirrors and lenses providing an integration platform for photonic IC assembly and optical fiber interconnect. Thin glass is commercially available in panel and wafer formats and characterizes excellent optical and high-frequency properties. That makes it perfect for microsystem packaging. The paper presents recent results in single-mode waveguide technology on wafer level and waveguide characterization. Furthermore the integration in a

  13. Visions of Vision: An Exploratory Study of the Role College and University Presidents Play in Developing Institutional Vision

    ERIC Educational Resources Information Center

    McWade, Jessica C.

    2014-01-01

    This qualitative research explores how college and university presidents engage in the process of developing formal institutional vision. The inquiry identifies roles presidents play in vision development, which is often undertaken as part of strategic-planning initiatives. Two constructs of leadership and institutional vision are used to examine…

  14. Modelling of dispersal and deposition of impact glass spherules from the Cretaceous-Tertiary boundary deposit

    NASA Technical Reports Server (NTRS)

    Espindola, J. M.; Carey, S.; Sigurdsson, H.

    1993-01-01

    The dispersal of glass spherules or tektites from a bolide impact with the Earth is modelled as ballistic trajectories in standard atmosphere. Ballistic dispersal of Cretaceous-Tertiary boundary impact glass spherules found in Haiti and Mimbral, Mexico requires a fireball radius in excess of 50 km but less than 100 km to account for the observed distribution. Glass spherules from 1 and up to 8 mm in diameter have been found at the KT boundary at Beloc in Haiti, at Mimbral, Mexico, and at DSDP Sites 536 and 540 in the Gulf of Mexico corresponding to paleodistances of 600 to 1000 km from the Chicxulub crater. In Haiti the basal and major glass-bearing unit at the KT boundary is attributed to fallout on basis of sedimentologic features. When compared with theoretical and observed dispersal of volcanic ejecta, the grain size versus distance relationship of the KT boundary tektite fallout is extreme, and rules out a volcanic fallout origin. At a comparable distance from source, the KT impact glass spherules are more than an order of mangitude coarser than ejecta of the largest known volcanic events. We model the dispersal of KT boundary impact glass spherules as ballistic ejecta from a fireball generated by the impact of a 10 km diameter bolide. Mass of ejecta in the fireball is taken as twice the bolide mass. Melt droplets are accelerated by gas flow in the fireball cloud, and leave the fireball on ballistic trajectories within the atmosphere, subject to drag, depending on angle of ejection and altitude. The model for ballistic dispersal is based on equations of motion, drag and ablation for silicate spheres in standard atmosphere.

  15. One-step femtosecond laser welding and internal machining of three glass substrates

    NASA Astrophysics Data System (ADS)

    Tan, Hua; Duan, Ji'an

    2017-05-01

    In this paper, it demonstrated one-step femtosecond laser welding and internal machining of three fused silica substrates in the optical- and non-optical-contact regimes by focusing 1030-nm laser pulses at the middle of the second substrate. Focusing laser pulses within the second glass in optical-contact and non-optical-contact samples induces permanent internal structural modification, leading to the three glass substrates bonding together simultaneously. The bonding mechanism is based on the internal modification of glass, and this mechanism is different from that of ordinary glass welding at the interface. Welding-spot size is affected by not only the gap distance (ablation effect) and heat transmission, but also by gravity through examining the sizes of the welding spots on the four contact welding surfaces. The maximum bonding strength of the lower interface (56.2 MPa) in the optical-contact regime is more than double that (27.6 MPa) in the non-optical-contact regime.

  16. Light Vision Color

    NASA Astrophysics Data System (ADS)

    Valberg, Arne

    2005-04-01

    Light Vision Color takes a well-balanced, interdisciplinary approach to our most important sensory system. The book successfully combines basics in vision sciences with recent developments from different areas such as neuroscience, biophysics, sensory psychology and philosophy. Originally published in 1998 this edition has been extensively revised and updated to include new chapters on clinical problems and eye diseases, low vision rehabilitation and the basic molecular biology and genetics of colour vision. Takes a broad interdisciplinary approach combining basics in vision sciences with the most recent developments in the area Includes an extensive list of technical terms and explanations to encourage student understanding Successfully brings together the most important areas of the subject in to one volume

  17. RBOOST: RIEMANNIAN DISTANCE BASED REGULARIZED BOOSTING

    PubMed Central

    Liu, Meizhu; Vemuri, Baba C.

    2011-01-01

    Boosting is a versatile machine learning technique that has numerous applications including but not limited to image processing, computer vision, data mining etc. It is based on the premise that the classification performance of a set of weak learners can be boosted by some weighted combination of them. There have been a number of boosting methods proposed in the literature, such as the AdaBoost, LPBoost, SoftBoost and their variations. However, the learning update strategies used in these methods usually lead to overfitting and instabilities in the classification accuracy. Improved boosting methods via regularization can overcome such difficulties. In this paper, we propose a Riemannian distance regularized LPBoost, dubbed RBoost. RBoost uses Riemannian distance between two square-root densities (in closed form) – used to represent the distribution over the training data and the classification error respectively – to regularize the error distribution in an iterative update formula. Since this distance is in closed form, RBoost requires much less computational cost compared to other regularized Boosting algorithms. We present several experimental results depicting the performance of our algorithm in comparison to recently published methods, LP-Boost and CAVIAR, on a variety of datasets including the publicly available OASIS database, a home grown Epilepsy database and the well known UCI repository. Results depict that the RBoost algorithm performs better than the competing methods in terms of accuracy and efficiency. PMID:21927643

  18. Static and dynamic postural control in low-vision and normal-vision adults.

    PubMed

    Tomomitsu, Mônica S V; Alonso, Angelica Castilho; Morimoto, Eurica; Bobbio, Tatiana G; Greve, Julia M D

    2013-04-01

    This study aimed to evaluate the influence of reduced visual information on postural control by comparing low-vision and normal-vision adults in static and dynamic conditions. Twenty-five low-vision subjects and twenty-five normal sighted adults were evaluated for static and dynamic balance using four protocols: 1) the Modified Clinical Test of Sensory Interaction on Balance on firm and foam surfaces with eyes opened and closed; 2) Unilateral Stance with eyes opened and closed; 3) Tandem Walk; and 4) Step Up/Over. The results showed that the low-vision group presented greater body sway compared with the normal vision during balance on a foam surface (p≤0.001), the Unilateral Stance test for both limbs (p≤0.001), and the Tandem Walk test. The low-vision group showed greater step width (p≤0.001) and slower gait speed (p≤0.004). In the Step Up/Over task, low-vision participants were more cautious in stepping up (right p≤0.005 and left p≤0.009) and in executing the movement (p≤0.001). These findings suggest that visual feedback is crucial for determining balance, especially for dynamic tasks and on foam surfaces. Low-vision individuals had worse postural stability than normal-vision adults in terms of dynamic tests and balance on foam surfaces.

  19. Vision 2030. A Vision for the U.S. Concrete Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2001-01-01

    On September 27, 2000, the concrete industry's Strategic Development Council hosted a Concrete Vision Workshop in Chicago, Illinois. Meeting participants included over 50 concrete, cement, and other allied industry chief executive officers, presidents, vice-presidents, laboratory and industry research managers, and government representatives. Participants discussed the state of the concrete industry 30 years ago, the state of the current industry, and their vision for the United States concrete industry in 2030. Moreover, they identified specific goals to achieve the industry's Vision 2030. This document, Vision 2030, is the product of that workshop and the comments received after a broad industry review.

  20. Bioactive calcium pyrophosphate glasses and glass-ceramics.

    PubMed

    Kasuga, Toshihiro

    2005-01-01

    Calcium phosphate glass-based materials in the pyrophosphate region are briefly reviewed. Calcium pyrophosphate glasses can be prepared by including a small amount of TiO(2) (glasses in simulated body fluid. By heating powder-compacts of the glasses, they are crystallized and subsequently are sintered, resulting in fabrication of high-strength glass-ceramics with machinability; they are easier to be machined using conventional tools in comparison with conventional calcium phosphate ceramics. beta-Ca(2)P(2)O(7) crystal formed in the glass-ceramics plays an important role in the machinability. Their apatite-forming ability in simulated body fluid is drastically enhanced after autoclaving in distilled water. The glass-ceramics can be easily coated on a new beta-type titanium alloy using a conventional glazing technique.

  1. An imaging system based on laser optical feedback for fog vision applications

    NASA Astrophysics Data System (ADS)

    Belin, E.; Boucher, V.

    2008-08-01

    The Laboratoire Régional des Ponts et Chaussées d'Angers - LRPC of Angers is currently studying the feasability of applying an optical technique based on the principle of the laser optical feedback to long distance fog vision. Optical feedback set up allows the creation of images on roadsigns. To create artificial fog conditions we used a vibrating cell that produces a micro-spray of water according to the principle of acoustic cavitation. To scale the sensitivity of the system under duplicatible conditions we also used optical densities linked to first-sight visibility distances. The current system produces, in a few seconds, 200 × 200 pixel images of a roadsign seen through dense artificial fog.

  2. 77 FR 16890 - Eighteenth Meeting: RTCA Special Committee 213, Enhanced Flight Visions Systems/Synthetic Vision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-22

    ... Committee 213, Enhanced Flight Visions Systems/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation... 213, Enhanced Flight Visions Systems/Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing... Flight Visions Systems/Synthetic Vision Systems (EFVS/SVS). DATES: The meeting will be held April 17-19...

  3. 77 FR 56254 - Twentieth Meeting: RTCA Special Committee 213, Enhanced Flight Vision Systems/Synthetic Vision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-12

    ... Committee 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation... 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing... Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). DATES: The meeting will be held October 2-4...

  4. A generalized equation for the calculation of receptor noise limited colour distances in n-chromatic visual systems

    PubMed Central

    Clark, R. C.; Brebner, J. S.

    2017-01-01

    Researchers must assess similarities and differences in colour from an animal's eye view when investigating hypotheses in ecology, evolution and behaviour. Nervous systems generate colour perceptions by comparing the responses of different spectral classes of photoreceptor through colour opponent mechanisms, and the performance of these mechanisms is limited by photoreceptor noise. Accordingly, the receptor noise limited (RNL) colour distance model of Vorobyev and Osorio (Vorobyev & Osorio 1998 Proc. R. Soc. Lond. B 265, 351–358 (doi:10.1098/rspb.1998.0302)) generates predictions about the discriminability of colours that agree with behavioural data, and consequently it has found wide application in studies of animal colour vision. Vorobyev and Osorio (1998) provide equations to calculate RNL colour distances for animals with di-, tri- and tetrachromatic vision, which is adequate for many species. However, researchers may sometimes wish to compute RNL colour distances for potentially more complex colour visual systems. Thus, we derive a simple, single formula for the computation of RNL distance between two measurements of colour, equivalent to the published di-, tri- and tetrachromatic equations of Vorobyev and Osorio (1998), and valid for colour visual systems with any number of types of noisy photoreceptors. This formula will allow the easy application of this important colour visual model across the fields of ecology, evolution and behaviour. PMID:28989773

  5. A stingless bee can use visual odometry to estimate both height and distance.

    PubMed

    Eckles, M A; Roubik, D W; Nieh, J C

    2012-09-15

    Bees move and forage within three dimensions and rely heavily on vision for navigation. The use of vision-based odometry has been studied extensively in horizontal distance measurement, but not vertical distance measurement. The honey bee Apis mellifera and the stingless bee Melipona seminigra measure distance visually using optic flow-movement of images as they pass across the retina. The honey bees gauge height using image motion in the ventral visual field. The stingless bees forage at different tropical forest canopy levels, ranging up to 40 m at our site. Thus, estimating height would be advantageous. We provide the first evidence that the stingless bee Melipona panamica utilizes optic flow information to gauge not only distance traveled but also height above ground, by processing information primarily from the lateral visual field. After training bees to forage at a set height in a vertical tunnel lined with black and white stripes, we observed foragers that explored a new tunnel with no feeder. In a new tunnel, bees searched at the same height they were trained to. In a narrower tunnel, bees experienced more image motion and significantly lowered their search height. In a wider tunnel, bees experienced less image motion and searched at significantly greater heights. In a tunnel without optic cues, bees were disoriented and searched at random heights. A horizontal tunnel testing these variables similarly affected foraging, but bees exhibited less precision (greater variance in search positions). Accurately gauging flight height above ground may be crucial for this species and others that compete for resources located at heights ranging from ground level to the high tropical forest canopies.

  6. Eco-efficient waste glass recycling: Integrated waste management and green product development through LCA.

    PubMed

    Blengini, Gian Andrea; Busto, Mirko; Fantoni, Moris; Fino, Debora

    2012-05-01

    As part of the EU Life + NOVEDI project, a new eco-efficient recycling route has been implemented to maximise resources and energy recovery from post-consumer waste glass, through integrated waste management and industrial production. Life cycle assessment (LCA) has been used to identify engineering solutions to sustainability during the development of green building products. The new process and the related LCA are framed within a meaningful case of industrial symbiosis, where multiple waste streams are utilised in a multi-output industrial process. The input is a mix of rejected waste glass from conventional container glass recycling and waste special glass such as monitor glass, bulbs and glass fibres. The green building product is a recycled foam glass (RFG) to be used in high efficiency thermally insulating and lightweight concrete. The environmental gains have been contrasted against induced impacts and improvements have been proposed. Recovered co-products, such as glass fragments/powders, plastics and metals, correspond to environmental gains that are higher than those related to landfill avoidance, whereas the latter is cancelled due to increased transportation distances. In accordance to an eco-efficiency principle, it has been highlighted that recourse to highly energy intensive recycling should be limited to waste that cannot be closed-loop recycled. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Acquired color vision deficiency.

    PubMed

    Simunovic, Matthew P

    2016-01-01

    Acquired color vision deficiency occurs as the result of ocular, neurologic, or systemic disease. A wide array of conditions may affect color vision, ranging from diseases of the ocular media through to pathology of the visual cortex. Traditionally, acquired color vision deficiency is considered a separate entity from congenital color vision deficiency, although emerging clinical and molecular genetic data would suggest a degree of overlap. We review the pathophysiology of acquired color vision deficiency, the data on its prevalence, theories for the preponderance of acquired S-mechanism (or tritan) deficiency, and discuss tests of color vision. We also briefly review the types of color vision deficiencies encountered in ocular disease, with an emphasis placed on larger or more detailed clinical investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Reading performance of monofocal pseudophakic patients with and without glasses under normal and dim light conditions.

    PubMed

    Radner, Wolfgang; Radner, Stephan; Raunig, Valerian; Diendorfer, Gabriela

    2014-03-01

    To evaluate reading performance of patients with monofocal intraocular lenses (IOLs) (Acrysof SN60WF) with or without reading glasses under bright and dim light conditions. Austrian Academy of Ophthalmology, Vienna, Austria. Evaluation of a diagnostic test or technology. In pseudophakic patients, the spherical refractive error was limited to between +0.50 diopter (D) and -0.75 D with astigmatism of 0.75 D (mean spherical equivalent: right eye, -0.08 ± 0.43 [SD]; left eye, -0.15 ± 0.35). Near addition was +2.75 D. Reading performance was assessed binocularly with or without reading glasses at an illumination of 100 candelas (cd)/m(2) and 4 cd/m(2) using the Radner Reading Charts. In the 25 patients evaluated, binocularly, the mean corrected distance visual acuity was -0.07 ± 0.06 logMAR and the mean uncorrected distance visual acuity was 0.01 ± 0.11 logMAR. The mean reading acuity with reading glasses was 0.02 ± 0.10 logRAD at 100 cd/m(2) and 0.12 ± 0.14 logRAD at 4 cd/m(2). Without reading glasses, it was 0.44 ± 0.13 logRAD and 0.56 ± 0.16 logRAD, respectively (P < .05). Without reading glasses and at 100 cd/m(2), 40% of patients read 0.4 logRAD at more than 80 words per minute (wpm), 68% exceeded this limit at 0.5 logRAD, and 92% exceeded it at 0.6 logRAD. The mean reading speed at 0.5 logRAD was 134.76 ± 48.22 wpm; with reading glasses it was 167.65 ± 32.77 wpm (P < .05). A considerable percentage of patients with monofocal IOLs read newspaper print size without glasses under good light conditions. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Gaze behavior and the perception of egocentric distance

    PubMed Central

    Gajewski, Daniel A.; Wallin, Courtney P.; Philbeck, John W.

    2014-01-01

    The ground plane is thought to be an important reference for localizing objects, particularly when angular declination is informative, as it is for objects seen resting at floor level. A potential role for eye movements has been implicated by the idea that information about the nearby ground is required to localize objects more distant, and by the fact that the time course for the extraction of distance extends beyond the duration of a typical eye fixation. To test this potential role, eye movements were monitored when participants previewed targets. Distance estimates were provided by walking without vision to the remembered target location (blind walking) or by verbal report. We found that a strategy of holding the gaze steady on the object was as frequent as one where the region between the observer and object was fixated. There was no performance advantage associated with making eye movements in an observational study (Experiment 1) or when an eye-movement strategy was manipulated experimentally (Experiment 2). Observers were extracting useful information covertly, however. In Experiments 3 through 5, obscuring the nearby ground plane had a modest impact on performance; obscuring the walls and ceiling was more detrimental. The results suggest that these alternate surfaces provide useful information when judging the distance to objects within indoor environments. Critically, they constrain the role for the nearby ground plane in theories of egocentric distance perception. PMID:24453346

  10. Design and Development of a High Speed Sorting System Based on Machine Vision Guiding

    NASA Astrophysics Data System (ADS)

    Zhang, Wenchang; Mei, Jiangping; Ding, Yabin

    In this paper, a vision-based control strategy to perform high speed pick-and-place tasks on automation product line is proposed, and relevant control software is develop. Using Delta robot to control a sucker to grasp disordered objects from one moving conveyer and then place them on the other in order. CCD camera gets one picture every time the conveyer moves a distance of ds. Objects position and shape are got after image processing. Target tracking method based on "Servo motor + synchronous conveyer" is used to fulfill the high speed porting operation real time. Experiments conducted on Delta robot sorting system demonstrate the efficiency and validity of the proposed vision-control strategy.

  11. Trial Frame Refraction versus Autorefraction among New Patients in a Low-Vision Clinic

    PubMed Central

    DeCarlo, Dawn K.; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia

    2013-01-01

    Purpose. To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. Methods. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Results. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J0 and J45 were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (−8.6 to 4.9). Conclusions. Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction. PMID:23188726

  12. Trial frame refraction versus autorefraction among new patients in a low-vision clinic.

    PubMed

    DeCarlo, Dawn K; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia

    2013-01-02

    To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J(0) and J(45) were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (-8.6 to 4.9). Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction.

  13. Correlation Between Vision and Cognitive Function in the Elderly

    PubMed Central

    Spierer, Oriel; Fischer, Naomi; Barak, Adiel; Belkin, Michael

    2016-01-01

    Abstract The correlation between vision and cognition is not fully understood. Visual impairment in the elderly has been associated with impaired cognitive function, dementia, and Alzheimer disease. The aim was to study the correlation between near visual acuity (VA), refraction, and cognitive state in an elderly population. Subjects ≥75 years were enrolled in this cross-sectional study. Refraction and near VA was tested. Cognitive function was evaluated with a version of the mini-mental state examination for the visually impaired (MMSE-blind). The eye with better VA and no cataract or refractive surgery was analyzed. One-hundred ninety subjects (81.6 ± 5.1 years, 69.5% female) were included. Good VA (≤J3) was associated with high MMSE-blind (>17) (OR = 3.18, 95% CI = 1.57–6.43, P = 0.001). This remained significant adjusting for sex, age, and years of education. Wearing reading glasses correlated significantly with high MMSE-blind after adjustment for sex and age (OR = 2.14, 95% CI = 1.16–3.97, P = 0.016), but reached borderline significance after adjustment for education. There was a trend toward correlation between myopia and better MMSE-blind (r = −0.123, P = 0.09, Pearson correlation). Good VA and wearing glasses seem to correlate with better cognitive function. Reading glasses can serve as a protective factor against cognitive deterioration associated with sensory (visual) deprivation in old age. The association between myopia and cognition requires further investigation. PMID:26817872

  14. Composition Dependence of the Na(+) Ion Conductivity in 0.5Na2S + 0.5[xGeS2 + (1 - x)PS5/2] Mixed Glass Former Glasses: A Structural Interpretation of a Negative Mixed Glass Former Effect.

    PubMed

    Martin, Steve W; Bischoff, Christian; Schuller, Katherine

    2015-12-24

    A negative mixed glass former effect (MGFE) in the Na(+) ion conductivity of glass has been found in 0.5Na2S + 0.5[xGeS2 + (1 - x)PS5/2] glasses where the Na(+) ion conductivity is significantly smaller for all of the ternary glasses than either of the binary end-member glasses. The minimum conductivity of ∼0.4 × 10(-6) (Ω cm)(-1) at 25 °C occurs for the x = 0.7 glass. Prior to this observation, the alkali ion conductivity of sulfide glasses at constant alkali concentration, but variable ratio of one glass former for another (x) ternary mixed glass former (MGF) glasses, has always produced a positive MGFE in the alkali ion conductivity; that is, the ternary glasses have always had higher ion conductivities that either of the end-member binary glasses. While the Na(+) ion conductivity exhibits a single global minimum value, the conductivity activation energy exhibits a bimodal double maximum at x ≈ 0.4 and x ≈ 0.7. The modified Christensen-Martin-Anderson-Stuart (CMAS) model of the activation energies reveals the origin of the negative MGFE to be due to an increase in the dielectric stiffness (a decrease in relative dielectric permittivity) of these glasses. When coupled with an increase in the average Na(+) ion jump distance and a slight increase in the mechanical stiffness of the glass, this causes the activation energy to go through maximum values and thereby produce the negative MGFE. The double maximum in the conductivity activation energy is coincident with double maximums in CMAS calculated strain, ΔES, and Coulombic, ΔEC, activation energies. In these ternary glasses, the increase in the dielectric stiffness of the glass arises from a negative deviation of the limiting high frequency dielectric permittivity as compared to the binary end-member glasses. While the CMAS calculated total activation energies ΔEact = ΔES + ΔEC are found to reproduce the overall shape of the composition dependence of the measured ΔEact values, they are consistently

  15. Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals

    PubMed Central

    Molina-Torres, María-José; Crespo, María-del-Mar Seguí; Francés, Ana Tauste; Lacarra, Blanca Lumbreras; Ronda-Pérez, Elena

    2016-01-01

    Objective: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. Methods: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. Results: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). Conclusions: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test

  16. The World Water Vision: From Developing a Vision to Action

    NASA Astrophysics Data System (ADS)

    Gangopadhyay, S.; Cosgrove, W.; Rijsberman, F.; Strzepek, K.; Strzepek, K.

    2001-05-01

    The World Water Vision exercise was initiated by the World Water Commission under the auspices of the World Water Council. The goal of the World Water Vision project was to develop a widely shared vision on the actions required to achieve a common set of water-related goals and the necessary commitment to carry out these actions. The Vision should be participatory in nature, including input from both developed and developing regions, with a special focus on the needs of the poor, women, youth, children and the environment. Three overall objectives were to: (i)raise awareness of water issues among both the general population and decision-makers so as to foster the necessary political will and leadership to tackle the problems seriously and systematically; (ii) develop a vision of water management for 2025 that is shared by water sector specialists as well as international, national and regional decision-makers in government, the private sector and civil society; and (iii) provide input to a Framework for Action to be elaborated by the Global Water Partnership, with steps to go from vision to action, including recommendations to funding agencies for investment priorities. This exercise was characterized by the principles of: (i) a participatory approach with extensive consultation; (ii) Innovative thinking; (iii) central analysis to assure integration and co-ordination; and (iv) emphasis on communication with groups outside the water sector. The primary activities included, developing global water scenarios that fed into regional consultations and sectoral consultations as water for food, water for people - water supply and sanitation, and water and environment. These consultations formulated the regional and sectoral visions that were synthesized to form the World Water Vision. The findings from this exercise were reported and debated at the Second World Water Forum and the Ministerial Conference held in The Hague, The Netherlands during April 2000. This paper

  17. Proprioceptive Distance Cues Restore Perfect Size Constancy in Grasping, but Not Perception, When Vision Is Limited.

    PubMed

    Chen, Juan; Sperandio, Irene; Goodale, Melvyn Alan

    2018-03-19

    Our brain integrates information from multiple modalities in the control of behavior. When information from one sensory source is compromised, information from another source can compensate for the loss. What is not clear is whether the nature of this multisensory integration and the re-weighting of different sources of sensory information are the same across different control systems. Here, we investigated whether proprioceptive distance information (position sense of body parts) can compensate for the loss of visual distance cues that support size constancy in perception (mediated by the ventral visual stream) [1, 2] versus size constancy in grasping (mediated by the dorsal visual stream) [3-6], in which the real-world size of an object is computed despite changes in viewing distance. We found that there was perfect size constancy in both perception and grasping in a full-viewing condition (lights on, binocular viewing) and that size constancy in both tasks was dramatically disrupted in the restricted-viewing condition (lights off; monocular viewing of the same but luminescent object through a 1-mm pinhole). Importantly, in the restricted-viewing condition, proprioceptive cues about viewing distance originating from the non-grasping limb (experiment 1) or the inclination of the torso and/or the elbow angle of the grasping limb (experiment 2) compensated for the loss of visual distance cues to enable a complete restoration of size constancy in grasping but only a modest improvement of size constancy in perception. This suggests that the weighting of different sources of sensory information varies as a function of the control system being used. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Aerial vehicles collision avoidance using monocular vision

    NASA Astrophysics Data System (ADS)

    Balashov, Oleg; Muraviev, Vadim; Strotov, Valery

    2016-10-01

    In this paper image-based collision avoidance algorithm that provides detection of nearby aircraft and distance estimation is presented. The approach requires a vision system with a single moving camera and additional information about carrier's speed and orientation from onboard sensors. The main idea is to create a multi-step approach based on a preliminary detection, regions of interest (ROI) selection, contour segmentation, object matching and localization. The proposed algorithm is able to detect small targets but unlike many other approaches is designed to work with large-scale objects as well. To localize aerial vehicle position the system of equations relating object coordinates in space and observed image is solved. The system solution gives the current position and speed of the detected object in space. Using this information distance and time to collision can be estimated. Experimental research on real video sequences and modeled data is performed. Video database contained different types of aerial vehicles: aircrafts, helicopters, and UAVs. The presented algorithm is able to detect aerial vehicles from several kilometers under regular daylight conditions.

  19. Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enqvist, Andreas; Koppal, Sanjeev

    2015-07-01

    and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are

  20. Assistive technology for children and young people with low vision.

    PubMed

    Thomas, Rachel; Barker, Lucy; Rubin, Gary; Dahlmann-Noor, Annegret

    2015-06-18

    Recent technological developments, such as the near universal spread of mobile phones and portable computers and improvements in the accessibility features of these devices, give children and young people with low vision greater independent access to information. Some electronic technologies, such as closed circuit TV, are well established low vision aids and newer versions, such as electronic readers or off-the shelf tablet computers, may offer similar functionalities with easier portability and at lower cost. To assess the effect of electronic assistive technologies on reading, educational outcomes and quality of life in children and young people with low vision. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2014), EMBASE (January 1980 to October 2014), the Health Technology Assessment Programme (HTA) (www.hta.ac.uk/), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 30 October 2014. We intended to include randomised controlled trials (RCTs) and quasi-RCTs in this review. We planned to include trials involving children between the ages of 5 and 16 years with low vision as defined by, or equivalent to, the WHO 1992 definition of low vision. We planned to include studies that explore the use of assistive technologies (ATs). These could include all types of closed circuit television/electronic vision enhancement systems (CCTV/EVES), computer technology including tablet computers and adaptive technologies such as screen readers, screen magnification and

  1. A pseudoisochromatic test of color vision for human infants.

    PubMed

    Mercer, Michele E; Drodge, Suzanne C; Courage, Mary L; Adams, Russell J

    2014-07-01

    Despite the development of experimental methods capable of measuring early human color vision, we still lack a procedure comparable to those used to diagnose the well-identified congenital and acquired color vision anomalies in older children, adults, and clinical patients. In this study, we modified a pseudoisochromatic test to make it more suitable for young infants. Using a forced choice preferential looking procedure, 216 3-to-23-mo-old babies were tested with pseudoisochromatic targets that fell on either a red/green or a blue/yellow dichromatic confusion axis. For comparison, 220 color-normal adults and 22 color-deficient adults were also tested. Results showed that all babies and adults passed the blue/yellow target but many of the younger infants failed the red/green target, likely due to the interaction of the lingering immaturities within the visual system and the small CIE vector distance within the red/green plate. However, older (17-23 mo) infants, color- normal adults and color-defective adults all performed according to expectation. Interestingly, performance on the red/green plate was better among female infants, well exceeding the expected rate of genetic dimorphism between genders. Overall, with some further modification, the test serves as a promising tool for the detection of early color vision anomalies in early human life. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. An ancient explanation of presbyopia based on binocular vision.

    PubMed

    Barbero, Sergio

    2014-06-01

    Presbyopia, understood as the age-related loss of ability to clearly see near objects, was known to ancient Greeks. However, few references to it can be found in ancient manuscripts. A relevant discussion on presbyopia appears in a book called Symposiacs written by Lucius Mestrius Plutarchus around 100 A.C. In this work, Plutarch provided four explanations of presbyopia, associated with different theories of vision. One of the explanations is particularly interesting as it is based on a binocular theory of vision. In this theory, vision is produced when visual rays, emanating from the eyes, form visual cones that impinge on the objects to be seen. Visual rays coming from old people's eyes, it was supposed, are weaker than those from younger people's eyes; so the theory, to be logically coherent, implies that this effect is compensated by the increase in light intensity due to the overlapping, at a certain distance, of the visual cones coming from both eyes. Thus, it benefits the reader to move the reading text further away from the eyes in order to increase the fusion area of both visual cones. The historical hypothesis taking into consideration that the astronomer Hipparchus of Nicaea was the source of Plutarch's explanation of the theory is discussed. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Impact of correcting visual impairment and low vision in deaf-mute students in Pune, India.

    PubMed

    Gogate, Parikshit; Bhusan, Shashi; Ray, Shantanu; Shinde, Amit

    2016-12-01

    The aim of this study was to evaluate visual acuity and vision function before and after providing spectacles and low vision devices (LVDs) in deaf-mute students. Schools for deaf-mute in West Maharashtra. Hearing-impaired children in all special schools in Pune district underwent detailed visual acuity testing (with teachers' help), refraction, external ocular examination, and fundoscopy. Students with refractive errors and low vision were provided with spectacles and LVD. The LV Prasad-Functional Vision Questionnaire consisting of twenty items was administered to each subject before and after providing spectacles, LVDs. Wilcoxon matched-pairs signed-ranks test. 252/929 (27.1%) students had a refractive error. 794 (85.5%) were profound deaf. Two-hundred and fifty students were dispensed spectacles and LVDs. Mean LogMAR visual acuity before introduction of spectacles and LVDs were 0.33 ± 0.36 which improved to 0.058 (P < 0.0001) after intervention. It was found that difference in functional vision pre- and post-intervention was statistically significant (P < 0.0001) for questions 1-19. The most commonly reported difficulties were for performing distance task like reading the bus destination (58.7%), making out the bus number (51.1%), copying from blackboard (47.7%), and seeing whether somebody is waving hand from across the road (45.5%). In response to question number 20, 57.4% of students felt that their vision was much worse than their friend's vision, which was reduced to 17.6% after dispensing spectacles and LVDs. Spectacle and LVD reduced visual impairment and improved vision function in deaf-mute students, augmenting their ability to negotiate in and out of school.

  4. The Vision Outreach Project: A Pilot Project to Train Teachers of Visually Impaired Students in Alabama.

    ERIC Educational Resources Information Center

    Sanspree, M. J.; And Others

    1991-01-01

    This article describes the Vision Outreach Project--a pilot project of the University of Alabama at Birmingham for training teachers of visually impaired students. The project produced video modules to provide distance education in rural and urban areas. The modules can be used to complete degree requirements or in-service training and continuing…

  5. Electrochromic Glasses.

    DTIC Science & Technology

    1980-07-31

    this glass and that dipole-dipole correlations contribute to the "ferroelectric-like" character of this amorphous system. The TeO2 -W03 glasses can only...shows the dielectric constant and Fig. I(b) glass from pure TeO2 ot pure WO. In addition, glass the tan 8 of the WO glass as a function of temperature... glasses containing WO, in various glass forming nitworks of LifO-B1O0, Na:O-BzO,, and TeO2 were prepared from reagent grade oxides at 800 C - 9SO C in

  6. FLORA™: Phase I development of a functional vision assessment for prosthetic vision users

    PubMed Central

    Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy

    2014-01-01

    Background Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population in order to evaluate the impact of new vision restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional vision ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. Methods The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional vision tasks for observation of performance, and a case narrative summary. Results were analyzed to determine whether the interview questions and functional vision tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, twenty-six subjects were assessed with the FLORA. Seven different evaluators administered the assessment. Results All 14 interview questions were asked. All 35 functional vision tasks were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options -- impossible (33%), difficult (23%), moderate (24%) and easy (19%) -- were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with vision only occurring 75% on average with the System ON, and 29% with the System OFF. Conclusion The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as a functional vision and well-being assessment tool. PMID:25675964

  7. Comparative analysis of visual outcomes with 4 intraocular lenses: Monofocal, multifocal, and extended range of vision.

    PubMed

    Pedrotti, Emilio; Carones, Francesco; Aiello, Francesco; Mastropasqua, Rodolfo; Bruni, Enrico; Bonacci, Erika; Talli, Pietro; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2018-02-01

    To compare the visual acuity, refractive outcomes, and quality of vision in patients with bilateral implantation of 4 intraocular lenses (IOLs). Department of Neurosciences, Biomedicine and Movement Sciences, Eye Clinic, University of Verona, Verona, and Carones Ophthalmology Center, Milano, Italy. Prospective case series. The study included patients who had bilateral cataract surgery with the implantation of 1 of 4 IOLs as follows: Tecnis 1-piece monofocal (monofocal IOL), Tecnis Symfony extended range of vision (extended-range-of-vision IOL), Restor +2.5 diopter (D) (+2.5 D multifocal IOL), and Restor +3.0 D (+3.0 D multifocal IOL). Visual acuity, refractive outcome, defocus curve, objective optical quality, contrast sensitivity, spectacle independence, and glare perception were evaluated 6 months after surgery. The study comprised 185 patients. The extended-range-of-vision IOL (55 patients) showed better distance visual outcomes than the monofocal IOL (30 patients) and high-addition apodized diffractive-refractive multifocal IOLs (P ≤ .002). The +3.0 D multifocal IOL (50 patients) showed the best near visual outcomes (P < .001). The +2.5 D multifocal IOL (50 patients) and extended-range-of-vision IOL provided significantly better intermediate visual outcomes than the other 2 IOLs, with significantly better vision for a defocus level of -1.5 D (P < .001). Better spectacle independence was shown for the +2.5 D multifocal IOL and extended-range-of-vision IOL (P < .001). The extended-range-of-vision IOL and +2.5 D multifocal IOL provided significantly better intermediate visual restoration after cataract surgery than the monofocal IOL and +3.0 D multifocal IOL, with significantly better quality of vision with the extended-range-of-vision IOL. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Computational approaches to vision

    NASA Technical Reports Server (NTRS)

    Barrow, H. G.; Tenenbaum, J. M.

    1986-01-01

    Vision is examined in terms of a computational process, and the competence, structure, and control of computer vision systems are analyzed. Theoretical and experimental data on the formation of a computer vision system are discussed. Consideration is given to early vision, the recovery of intrinsic surface characteristics, higher levels of interpretation, and system integration and control. A computational visual processing model is proposed and its architecture and operation are described. Examples of state-of-the-art vision systems, which include some of the levels of representation and processing mechanisms, are presented.

  9. Glass Research

    NASA Technical Reports Server (NTRS)

    Weinberg, M. C.

    1985-01-01

    Research efforts span three general areas of glass science: glass refining, gel-derived glasses, and nucleation and crystallization of glasses. Gas bubbles which are present in a glass product are defects which may render the glass totally useless for the end application. For example, optical glasses, laser host glasses, and a variety of other specialty glasses must be prepared virtually defect free to be employable. Since a major mechanism of bubble removal, buoyant rise, is virtually inoperative in microgravity, glass fining will be especially difficult in space. On the other hand, the suppression of buoyant rise and the ability to perform containerless melting experiments in space allows the opportunity to carry out several unique bubble experiments in space. Gas bubble dissolution studies may be performed at elevated temperatures for large bubbles with negligible bubble motion. Also, bubble nucleation studies may be performed without the disturbing feature of heterogeneous bubble nucleation at the platinum walls. Ground based research efforts are being performed in support of these potential flight experiments.

  10. 77 FR 2342 - Seventeenth Meeting: RTCA Special Committee 213, Enhanced Flight Vision/Synthetic Vision Systems...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-17

    ... Committee 213, Enhanced Flight Vision/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation..., Enhanced Flight Vision/ Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing this notice to advise the public of the seventeenth meeting of RTCA Special Committee 213, Enhanced Flight Vision...

  11. A Magnifying Glass for Virtual Imaging of Subwavelength Resolution by Transformation Optics.

    PubMed

    Sun, Fei; Guo, Shuwei; Liu, Yichao; He, Sailing

    2018-06-14

    Traditional magnifying glasses can give magnified virtual images with diffraction-limited resolution, that is, detailed information is lost. Here, a novel magnifying glass by transformation optics, referred to as a "superresolution magnifying glass" (SMG) is designed, which can produce magnified virtual images with a predetermined magnification factor and resolve subwavelength details (i.e., light sources with subwavelength distances can be resolved). Based on theoretical calculations and reductions, a metallic plate structure to produce the reduced SMG in microwave frequencies, which gives good performance verified by both numerical simulations and experimental results, is proposed and realized. The function of SMG is to create a superresolution virtual image, unlike traditional superresolution imaging devices that create real images. The proposed SMG will create a new branch of superresolution imaging technology. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Helicopter flights with night-vision goggles: Human factors aspects

    NASA Technical Reports Server (NTRS)

    Brickner, Michael S.

    1989-01-01

    Night-vision goggles (NVGs) and, in particular, the advanced, helmet-mounted Aviators Night-Vision-Imaging System (ANVIS) allows helicopter pilots to perform low-level flight at night. It consists of light intensifier tubes which amplify low-intensity ambient illumination (star and moon light) and an optical system which together produce a bright image of the scene. However, these NVGs do not turn night into day, and, while they may often provide significant advantages over unaided night flight, they may also result in visual fatigue, high workload, and safety hazards. These problems reflect both system limitations and human-factors issues. A brief description of the technical characteristics of NVGs and of human night-vision capabilities is followed by a description and analysis of specific perceptual problems which occur with the use of NVGs in flight. Some of the issues addressed include: limitations imposed by a restricted field of view; problems related to binocular rivalry; the consequences of inappropriate focusing of the eye; the effects of ambient illumination levels and of various types of terrain on image quality; difficulties in distance and slope estimation; effects of dazzling; and visual fatigue and superimposed symbology. These issues are described and analyzed in terms of their possible consequences on helicopter pilot performance. The additional influence of individual differences among pilots is emphasized. Thermal imaging systems (forward looking infrared (FLIR)) are described briefly and compared to light intensifier systems (NVGs). Many of the phenomena which are described are not readily understood. More research is required to better understand the human-factors problems created by the use of NVGs and other night-vision aids, to enhance system design, and to improve training methods and simulation techniques.

  13. 78 FR 5557 - Twenty-First Meeting: RTCA Special Committee 213, Enhanced Flight Vision Systems/Synthetic Vision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-25

    ... Committee 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS) AGENCY: Federal Aviation... 213, Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). SUMMARY: The FAA is issuing..., Enhanced Flight Vision Systems/Synthetic Vision Systems (EFVS/SVS). DATES: The meeting will be held...

  14. The Effectiveness of Distance Education in Allied Health Science Programs: A Meta-Analysis of Outcomes

    ERIC Educational Resources Information Center

    Williams, Stacy L.

    2006-01-01

    A comprehensive meta-analysis of the research following Glass, McGraw, and Smith's (1981) technique integrated findings from twenty-five comparative studies from 1990 to 2003 targeting student achievement and distance education in allied health professions. Student achievement was assessed through course grades and resulted in an overall effect…

  15. GlassForm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2011-09-16

    GlassForm is a software tool for generating preliminary waste glass formulas for a given waste stream. The software is useful because it reduces the number of verification melts required to develop a suitable additive composition. The software includes property models that calculate glass properties of interest from the chemical composition of the waste glass. The software includes property models for glass viscosity, electrical conductivity, glass transition temperature, and leach resistance as measured by the 7-day product consistency test (PCT).

  16. Glass and glass-ceramic photonic systems

    NASA Astrophysics Data System (ADS)

    Zur, Lidia; Thi Ngoc Tran, Lam; Meneghetti, Marcello; Varas, Stefano; Armellini, Cristina; Ristic, Davor; Chiasera, Alessandro; Scotognella, Francesco; Pelli, Stefano; Nunzi Conti, Gualtiero; Boulard, Brigitte; Zonta, Daniele; Dorosz, Dominik; Lukowiak, Anna; Righini, Giancarlo C.; Ramponi, Roberta; Ferrari, Maurizio

    2017-02-01

    The development of optically confined structure is a major topic in both basic and applied physics not solely ICT oriented but also concerning lighting, laser, sensing, energy, environment, biological and medical sciences, and quantum optics. Glasses and glass-ceramics activated by rare earth ions are the bricks of such structures. Glass-ceramics are nanocomposite systems that exhibit specific morphologic, structural and spectroscopic properties allowing developing new physical concepts, for instance the mechanism related to the transparency, as well as novel photonic devices based on the enhancement of the luminescence. The dependence of the final product on the specific parent glass and on the fabrication protocol still remain an important task of the research in material science. Looking to application, the enhanced spectroscopic properties typical of glass ceramic in respect to those of the amorphous structures constitute an important point for the development of integrated optics devices, including optical amplifiers, monolithic waveguide laser, novel sensors, coating of spherical microresonators, and up and down converters. This paper presents some results obtained by our consortium regarding glass-based photonics systems. We will comment the energy transfer mechanism in transparent glass ceramics taking as examples the up and down conversion systems and the role of SnO2 nanocrystals as sensitizers. Coating of spherical resonators by glass ceramics, 1D-Photonic Crystals for luminescence enhancement, laser action and disordered 1-D photonic structures will be also discussed. Finally, RF-Sputtered rare earth doped P2O5- SiO2-Al2O3-Na2O-Er2O3 planar waveguides, will be presented.

  17. Progress in computer vision.

    NASA Astrophysics Data System (ADS)

    Jain, A. K.; Dorai, C.

    Computer vision has emerged as a challenging and important area of research, both as an engineering and a scientific discipline. The growing importance of computer vision is evident from the fact that it was identified as one of the "Grand Challenges" and also from its prominent role in the National Information Infrastructure. While the design of a general-purpose vision system continues to be elusive machine vision systems are being used successfully in specific application elusive, machine vision systems are being used successfully in specific application domains. Building a practical vision system requires a careful selection of appropriate sensors, extraction and integration of information from available cues in the sensed data, and evaluation of system robustness and performance. The authors discuss and demonstrate advantages of (1) multi-sensor fusion, (2) combination of features and classifiers, (3) integration of visual modules, and (IV) admissibility and goal-directed evaluation of vision algorithms. The requirements of several prominent real world applications such as biometry, document image analysis, image and video database retrieval, and automatic object model construction offer exciting problems and new opportunities to design and evaluate vision algorithms.

  18. Improving Vignette Descriptions and Question Formats to Measure Distance Vision: Evidence from Cognitive Interviews among Students in China

    ERIC Educational Resources Information Center

    Su, Yanfang; Willis, Gordon; Salomon, Joshua A.

    2017-01-01

    Vignette design has been largely neglected in anchoring vignette studies. This study aimed to contribute to the science of vignette design by developing and evaluating vignettes for measuring vision in rural China. Cognitive interviews were conducted among 36 participants in a Chinese middle school. The respondents either directly evaluated vision…

  19. Computer vision

    NASA Technical Reports Server (NTRS)

    Gennery, D.; Cunningham, R.; Saund, E.; High, J.; Ruoff, C.

    1981-01-01

    The field of computer vision is surveyed and assessed, key research issues are identified, and possibilities for a future vision system are discussed. The problems of descriptions of two and three dimensional worlds are discussed. The representation of such features as texture, edges, curves, and corners are detailed. Recognition methods are described in which cross correlation coefficients are maximized or numerical values for a set of features are measured. Object tracking is discussed in terms of the robust matching algorithms that must be devised. Stereo vision, camera control and calibration, and the hardware and systems architecture are discussed.

  20. Biomimetic machine vision system.

    PubMed

    Harman, William M; Barrett, Steven F; Wright, Cameron H G; Wilcox, Michael

    2005-01-01

    Real-time application of digital imaging for use in machine vision systems has proven to be prohibitive when used within control systems that employ low-power single processors without compromising the scope of vision or resolution of captured images. Development of a real-time machine analog vision system is the focus of research taking place at the University of Wyoming. This new vision system is based upon the biological vision system of the common house fly. Development of a single sensor is accomplished, representing a single facet of the fly's eye. This new sensor is then incorporated into an array of sensors capable of detecting objects and tracking motion in 2-D space. This system "preprocesses" incoming image data resulting in minimal data processing to determine the location of a target object. Due to the nature of the sensors in the array, hyperacuity is achieved thereby eliminating resolutions issues found in digital vision systems. In this paper, we will discuss the biological traits of the fly eye and the specific traits that led to the development of this machine vision system. We will also discuss the process of developing an analog based sensor that mimics the characteristics of interest in the biological vision system. This paper will conclude with a discussion of how an array of these sensors can be applied toward solving real-world machine vision issues.

  1. The impact of loupes and microscopes on vision in endodontics.

    PubMed

    Perrin, P; Neuhaus, K W; Lussi, A

    2014-05-01

    To report on an intraradicular visual test in a simulated clinical setting under different optical conditions. Miniaturized visual tests with E-optotypes (bar distance from 0.01 to 0.05 mm) were fixed inside the root canal system of an extracted maxillary molar at different locations: at the orifice, a depth of 5 mm and the apex. The tooth was mounted in a phantom head for a simulated clinical setting. Unaided vision was compared with Galilean loupes (2.5× magnification) with integrated light source and an operating microscope (6× magnification). The influence of the dentists' age within two groups was evaluated: <40 years (n = 9) and ≥40 years (n = 15). Some younger dentists were able to identify the E-optotypes at the orifice, but otherwise, natural vision did not reveal any measurable result. With Galilean loupes, the younger dentists <40 years could see a 0.05 mm structure at the root canal orifice, in contrast to the older group ≥40 years. Only the microscope allowed the observation of structures inside the root canal, independent of age. Unaided vision and Galilean loupes with an integrated light source could not provide any measurable vision inside the root canal, but younger dentists <40 years could detect with Galilean loupes a canal orifice corresponding to the tip of the smallest endodontic instruments. Dentists over 40 years of age were dependent on the microscope to inspect the root canal system. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Aging and Vision

    PubMed Central

    Owsley, Cynthia

    2010-01-01

    Given the increasing size of the older adult population in many countries, there is a pressing need to identify the nature of aging-related vision impairments, their underlying mechanisms, and how they impact older adults’ performance of everyday visual tasks. The results of this research can then be used to develop and evaluate interventions to slow or reverse aging-related declines in vision, thereby improving quality of life. Here we summarize salient developments in research on aging and vision over the past 25 years, focusing on spatial contrast sensitivity, vision under low luminance, temporal sensitivity and motion perception, and visual processing speed. PMID:20974168

  3. Microwave vision for robots

    NASA Technical Reports Server (NTRS)

    Lewandowski, Leon; Struckman, Keith

    1994-01-01

    Microwave Vision (MV), a concept originally developed in 1985, could play a significant role in the solution to robotic vision problems. Originally our Microwave Vision concept was based on a pattern matching approach employing computer based stored replica correlation processing. Artificial Neural Network (ANN) processor technology offers an attractive alternative to the correlation processing approach, namely the ability to learn and to adapt to changing environments. This paper describes the Microwave Vision concept, some initial ANN-MV experiments, and the design of an ANN-MV system that has led to a second patent disclosure in the robotic vision field.

  4. Glass science tutorial: Lecture No. 7, Waste glass technology for Hanford

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, A.A.

    1995-07-01

    This paper presents the details of the waste glass tutorial session that was held to promote knowledge of waste glass technology and how this can be used at the Hanford Reservation. Topics discussed include: glass properties; statistical approach to glass development; processing properties of nuclear waste glass; glass composition and the effects of composition on durability; model comparisons of free energy of hydration; LLW glass structure; glass crystallization; amorphous phase separation; corrosion of refractories and electrodes in waste glass melters; and glass formulation for maximum waste loading.

  5. Electronic polarizability, optical basicity and interaction parameter for Nd2O3 doped lithium-zinc-phosphate glasses

    NASA Astrophysics Data System (ADS)

    Algradee, M. A.; Sultan, M.; Samir, O. M.; Alwany, A. Elwhab B.

    2017-08-01

    The Nd3+-doped lithium-zinc-phosphate glasses were prepared by means of conventional melt quenching method. X-ray diffraction results confirmed the glassy nature of the studied glasses. The physical parameters such as the density, molar volume, ion concentration, polaron radius, inter-ionic distance, field strength and oxygen packing density were calculated using different formulae. The transmittance and reflectance spectra of glasses were recorded in the wavelength range 190-1200 nm. The values of optical band gap and Urbach energy were determined based on Mott-Davis model. The refractive indices for the studied glasses were evaluated from optical band gap values using different methods. The average electronic polarizability of the oxide ions, optical basicity and an interaction parameter were investigated from the calculated values of the refractive index and the optical band gap for the studied glasses. The variations in the different physical and optical properties of glasses with Nd2O3 content were discussed in terms of different parameters such as non-bridging oxygen and different concentrations of Nd cation in glass system.

  6. The CCH Vision Stimulation Program for Infants with Low Vision: Preliminary Results.

    ERIC Educational Resources Information Center

    Leguire, L. E.; And Others

    1992-01-01

    This study evaluated the Columbus (Ohio) Children's Hospital vision stimulation program, involving in-home intervention with 15 visually impaired infants. Comparison with controls indicated benefits of appropriate vision stimulation in increasing the neural foundation for vision and visual-motor function in visually impaired infants. (Author/DB)

  7. Low vision system for rapid near- and far-field magnification switching.

    PubMed

    Ambrogi, Nicholas; Dias-Carlson, Rachel; Gantner, Karl; Gururaj, Anisha; Hanumara, Nevan; Narain, Jaya; Winter, Amos; Zielske, Iris; Satgunam, PremNandhini; Bagga, Deepak Kumar; Gothwal, Vijaya

    2015-01-01

    People suffering from low vision, a condition caused by a variety of eye-related diseases and/or disorders, find their ability to read greatly improved when text is magnified between 2 and 6 times. Assistive devices currently on the market are either geared towards reading text far away (~20 ft.) or very near (~2 ft.). This is a problem especially for students suffering from low vision, as they struggle to flip their focus between the chalkboard (far-field) and their notes (near- field). A solution to this problem is of high interest to eye care facilities in the developing world - no devices currently exist that have the aforementioned capabilities at an accessible price point. Through consultation with specialists at L.V. Prasad Eye Institute in India, the authors propose, design and demonstrate a device that fills this need, directed primarily at the Indian market. The device utilizes available hardware technologies to electronically capture video ahead of the user and zoom and display the image in real-time on LCD screens mounted in front of the user's eyes. This design is integrated as a wearable system in a glasses form-factor.

  8. Superexchange and spin-glass formation in semimagnetic semiconductors

    NASA Astrophysics Data System (ADS)

    Rusin, Tomasz M.

    1996-05-01

    The Mn-Mn superexchange interaction in semimagnetic semiconductors A1-xMnxB (where A=Zn, Cd and B=S, Se, Te) is studied within the three-level model of the band structure. We focus on the dependence of the interaction on the interion distance Jdd(r)=J0f(r). In the present work, the function f(r) is obtained analytically. This, only weakly material-dependent function is found to decrease with Mn-Mn distance much slower than its Gaussian approximation derived previously. The exact form of the decay of the superexchange can be approximated by a power law J0r-8.5. This is close to an experimental result, J0r-6.8, determined on the basis of the spin-glass transition temperature on the composition.

  9. Patient-reported benefit of ReSTOR® multi-focal intraocular lenses after cataract surgery: Results of Principal Component Analysis on clinical trial data

    PubMed Central

    Berdeaux, Gilles; Viala, Muriel; Roborel de Climens, Aude; Arnould, Benoit

    2008-01-01

    Background Restoration of functional distance and near vision independently of additional correction remains a goal for cataract surgery. ReSTOR®, a new multi-focal intraocular lens (IOL) addresses this issue with an improvement in both distance and near vision, often without need for glasses. This analysis attempted to discuss the patient-reported benefit of ReSTOR® using a full but organised representation of data. Methods Two non-randomised, open-label clinical trials conducted in Europe and the United-States were conducted to compare the efficacy of ReSTOR® to AcrySof® mono-focal IOLs. A total of 710 patients in need of bilateral cataract extraction were included in the pooled study. The TyPE, a patient questionnaire, was fully completed by 672 of them before and after each eye surgery. The TyPE, composed of 67 items measuring overall visual functioning in both conditions (with and without wearing glasses), evaluates limitations, troubles and satisfaction in distance and near vision. A principal component analysis (PCA) of the TyPE questionnaire was performed on pooled data from baseline and post-surgery observations in order to fully represent the change in the TyPE data over time. ReSTOR® and mono-focal groups were used as illustrative variables. The coordinates of the first 2 factors were compared between visits and between IOLs (ReSTOR® vs. mono-focal), using paired t-tests and t-tests, respectively. Results The first factor of the PCA explained 55% of the variance and represented 'visual functioning and patient satisfaction'. The second factor explained 6% of the variance and was interpreted as 'independence from glasses'. An overall difference in factorial coordinates in both factors was seen between baseline and the first eye surgery, and between the first and the second eye surgery. No difference between ReSTOR® and mono-focal IOL groups was observed at baseline. After surgery, ReSTOR® treated-patients had higher coordinates on both "visual

  10. Structure of rare-earth chalcogenide glasses by neutron and x-ray diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drewitt, James W. E.; Salmon, Philip S.; Zeidler, Anita

    The method of neutron diffraction with isomorphic substitution was used to measure the structure of the rare-earth chalcogenide glasses (R 2X 3) 0.07(Ga 2X 3) 0.33(GeX 2) 0.60 with R = La or Ce and X = S or Se. X-ray diffraction was also used to measure the structure of the sulphide glass. The results are consistent with networks that are built from GeX 4 and GaX 4 tetrahedra, and give R-S and R-Se coordination numbers of 8.0(2) and 8.5(4), respectively. The minimum nearest-neighbour R-R distance associated with rare-earth clustering is discussed.

  11. Structure of rare-earth chalcogenide glasses by neutron and x-ray diffraction

    DOE PAGES

    Drewitt, James W. E.; Salmon, Philip S.; Zeidler, Anita; ...

    2017-04-28

    The method of neutron diffraction with isomorphic substitution was used to measure the structure of the rare-earth chalcogenide glasses (R 2X 3) 0.07(Ga 2X 3) 0.33(GeX 2) 0.60 with R = La or Ce and X = S or Se. X-ray diffraction was also used to measure the structure of the sulphide glass. The results are consistent with networks that are built from GeX 4 and GaX 4 tetrahedra, and give R-S and R-Se coordination numbers of 8.0(2) and 8.5(4), respectively. The minimum nearest-neighbour R-R distance associated with rare-earth clustering is discussed.

  12. Developing a Very Low Vision Orientation and Mobility Test Battery (O&M-VLV).

    PubMed

    Finger, Robert P; Ayton, Lauren N; Deverell, Lil; O'Hare, Fleur; McSweeney, Shane C; Luu, Chi D; Fenwick, Eva K; Keeffe, Jill E; Guymer, Robyn H; Bentley, Sharon A

    2016-09-01

    This study aimed to determine the feasibility of an assessment of vision-related orientation and mobility (O&M) tasks in persons with severe vision loss. These tasks may be used for future low vision rehabilitation clinical assessments or as outcome measures in vision restoration trials. Forty legally blind persons (mean visual acuity logMAR 2.3, or hand movements) with advanced retinitis pigmentosa participated in the Orientation & Mobility-Very Low Vision (O&M-VLV) subtests from the Low Vision Assessment of Daily Activities (LoVADA) protocol. Four categories of tasks were evaluated: route travel in three indoor hospital environments, a room orientation task (the "cafe"), a visual exploration task (the "gallery"), and a modified version of the Timed Up and Go (TUG) test, which assesses re-orientation and route travel. Spatial cognition was assessed using the Stuart Tactile Maps test. Visual acuity and visual fields were measured. A generalized linear regression model showed that a number of measures in the O&M-VLV tasks were related to residual visual function. The percentage of preferred walking speed without an aid on three travel routes was associated with visual field (p < 0.01 for all routes) whereas the number of contacts with obstacles during route travel was associated with acuity (p = 0.001). TUG-LV task time was associated with acuity (p = 0.003), as was the cafe time and distance traveled (p = 0.006 and p < 0.001, respectively). The gallery score was the only measure that was significantly associated with both residual acuity and fields (p < 0.001 and p = 0.001, respectively). The O&M-VLV was designed to capture key elements of O&M performance in persons with severe vision loss, which is a population not often studied previously. Performance on these tasks was associated with both binocular visual acuity and visual field. This new protocol includes assessments of orientation, which may be of benefit in vision restoration clinical trials.

  13. Reaction cured glass and glass coatings

    NASA Technical Reports Server (NTRS)

    Goldstein, H. E.; Leiser, D. B.; Katvala, V. W. (Inventor)

    1978-01-01

    The invention relates to reaction cured glass and glass coatings prepared by reacting a compound selected from the group consisting of silicon tetraboride, silicon hexaboride, other boron silicides, boron and mixtures with a reactive glass frit composed of a porous high silica borosilicate glass and boron oxide. The glassy composites of the present invention are useful as coatings on low density fibrous porous silica insulations used as heat shields and for articles such as reaction vessels that are subjected to high temperatures with rapid heating and cooling and that require resistance to temperature and repeated thermal shock at temperatures up to about 1482C (2700PF).

  14. Facilitation of contrast detection in near-peripheral vision.

    PubMed

    Giorgi, Robert G; Soong, Grace P; Woods, Russell L; Peli, Eli

    2004-12-01

    Foveal detection of a Gabor patch (target) is facilitated by collinear, displaced high-contrast flankers. Polat and Sagi reported that the same phenomenon occurred in the periphery, but no data were presented [Proc. Natl. Acad. Sci. 91 (1994) 1206]. Others have found no facilitation in a limited number of conditions tested. To resolve this apparent conflict, we measured lateral facilitation in the near-periphery using a range of stimulus parameters. We found facilitation for a range of target-flanker distances for peripheral eccentricities up to 6 degrees , but the magnitude of the effect was less than found in central vision. Facilitation varied across subjects and with spatial frequency. Flanker contrast had no effect over the range evaluated (10-80%). Equal facilitation was found for two global arrangements of the stimulus pattern. Facilitation was found using a temporal, but not a spatial two-alternative forced-choice paradigm, accounting for the different results among previous studies. This finding supports previous indications of the role of attention in altering such facilitation. The value of facilitation from lateral interactions for persons with central vision impairment, who have to shift their attention to a peripheral locus constantly, needs to be examined.

  15. Mixed polyanion glass cathodes: Glass-state conversion reactions

    DOE PAGES

    Kercher, Andrew K.; Kolopus, James A.; Carroll, Kyler; ...

    2015-11-10

    Mixed polyanion (MP) glasses can undergo glass-state conversion (GSC) reactions to provide an alternate class of high-capacity cathode materials. GSC reactions have been demonstrated in phosphate/vanadate glasses with Ag, Co, Cu, Fe, and Ni cations. These MP glasses provided high capacity and good high power performance, but suffer from moderate voltages, large voltage hysteresis, and significant capacity fade with cycling. Details of the GSC reaction have been revealed by x-ray absorption spectroscopy, electron microscopy, and energy dispersive x-ray spectroscopy of ex situ cathodes at key states of charge. Using the Open Quantum Materials Database (OQMD), a computational thermodynamic model hasmore » been developed to predict the near-equilibrium voltages of glass-state conversion reactions in MP glasses.« less

  16. Barriers to accessing low vision services.

    PubMed

    Pollard, Tamara L; Simpson, John A; Lamoureux, Ecosse L; Keeffe, Jill E

    2003-07-01

    To investigate barriers to accessing low vision services in Australia. Adults with a vision impairment (<6/12 in the better eye and/or significant visual field defect), who were current patients at the Royal Victorian Eye and Ear Hospital (RVEEH), were interviewed. The questions investigated self-perceived vision difficulties, duration of vision loss and satisfaction with vision and also examined issues of awareness of low vision services and referral to services. Focus groups were also conducted with vision impaired (<6/12 in the better eye) patients from the RVEEH, listeners of the Radio for the Print Handicapped and peer workers at Vision Australia Foundation. The discussions were recorded and transcribed. The questionnaire revealed that referral to low vision services was associated with a greater degree of vision loss (p = 0.002) and a greater self-perception of low vision (p = 0.005) but that referral was not associated with satisfaction (p = 0.144) or difficulties related to vision (p = 0.169). Participants with mild and moderate vision impairment each reported similar levels of difficulties with daily activities and satisfaction with their vision (p > 0.05). However, there was a significant difference in the level of difficulties experienced with daily activities between those with mild-moderate and severe vision impairment (p < 0.05). The participants of the focus groups identified barriers to accessing low vision services related to awareness of services among the general public and eye care professionals, understanding of low vision and the services available, acceptance of low vision, the referral process, and transport. In addition to the expected difficulties with lack of awareness of services by people with low vision, many people do not understand what the services provide and do not identify themselves as having low vision. Knowledge of these barriers, from the perspective of people with low vision, can now be used to guide the development and

  17. Peripheral vision of youths with low vision: motion perception, crowding, and visual search.

    PubMed

    Tadin, Duje; Nyquist, Jeffrey B; Lusk, Kelly E; Corn, Anne L; Lappin, Joseph S

    2012-08-24

    Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10-17) and low vision (n = 24, ages 9-18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function.

  18. Scaling for hard-sphere colloidal glasses near jamming

    NASA Astrophysics Data System (ADS)

    Zargar, Rojman; DeGiuli, Eric; Bonn, Daniel

    2016-12-01

    Hard-sphere colloids are model systems in which to study the glass transition and universal properties of amorphous solids. Using covariance matrix analysis to determine the vibrational modes, we experimentally measure here the scaling behavior of the density of states, shear modulus, and mean-squared displacement (MSD) in a hard-sphere colloidal glass. Scaling the frequency with the boson-peak frequency, we find that the density of states at different volume fractions all collapse on a single master curve, which obeys a power law in terms of the scaled frequency. Below the boson peak, the exponent is consistent with theoretical results obtained by real-space and phase-space approaches to understanding amorphous solids. We find that the shear modulus and the MSD are nearly inversely proportional, and show a singular power-law dependence on the distance from random close packing. Our results are in very good agreement with the theoretical predictions.

  19. Vision restoration after brain and retina damage: the "residual vision activation theory".

    PubMed

    Sabel, Bernhard A; Henrich-Noack, Petra; Fedorov, Anton; Gall, Carolin

    2011-01-01

    Vision loss after retinal or cerebral visual injury (CVI) was long considered to be irreversible. However, there is considerable potential for vision restoration and recovery even in adulthood. Here, we propose the "residual vision activation theory" of how visual functions can be reactivated and restored. CVI is usually not complete, but some structures are typically spared by the damage. They include (i) areas of partial damage at the visual field border, (ii) "islands" of surviving tissue inside the blind field, (iii) extrastriate pathways unaffected by the damage, and (iv) downstream, higher-level neuronal networks. However, residual structures have a triple handicap to be fully functional: (i) fewer neurons, (ii) lack of sufficient attentional resources because of the dominant intact hemisphere caused by excitation/inhibition dysbalance, and (iii) disturbance in their temporal processing. Because of this resulting activation loss, residual structures are unable to contribute much to everyday vision, and their "non-use" further impairs synaptic strength. However, residual structures can be reactivated by engaging them in repetitive stimulation by different means: (i) visual experience, (ii) visual training, or (iii) noninvasive electrical brain current stimulation. These methods lead to strengthening of synaptic transmission and synchronization of partially damaged structures (within-systems plasticity) and downstream neuronal networks (network plasticity). Just as in normal perceptual learning, synaptic plasticity can improve vision and lead to vision restoration. This can be induced at any time after the lesion, at all ages and in all types of visual field impairments after retinal or brain damage (stroke, neurotrauma, glaucoma, amblyopia, age-related macular degeneration). If and to what extent vision restoration can be achieved is a function of the amount of residual tissue and its activation state. However, sustained improvements require repetitive

  20. Filtering and polychromatic vision in mantis shrimps: themes in visible and ultraviolet vision.

    PubMed

    Cronin, Thomas W; Bok, Michael J; Marshall, N Justin; Caldwell, Roy L

    2014-01-01

    Stomatopod crustaceans have the most complex and diverse assortment of retinal photoreceptors of any animals, with 16 functional classes. The receptor classes are subdivided into sets responsible for ultraviolet vision, spatial vision, colour vision and polarization vision. Many of these receptor classes are spectrally tuned by filtering pigments located in photoreceptors or overlying optical elements. At visible wavelengths, carotenoproteins or similar substances are packed into vesicles used either as serial, intrarhabdomal filters or lateral filters. A single retina may contain a diversity of these filtering pigments paired with specific photoreceptors, and the pigments used vary between and within species both taxonomically and ecologically. Ultraviolet-filtering pigments in the crystalline cones serve to tune ultraviolet vision in these animals as well, and some ultraviolet receptors themselves act as birefringent filters to enable circular polarization vision. Stomatopods have reached an evolutionary extreme in their use of filter mechanisms to tune photoreception to habitat and behaviour, allowing them to extend the spectral range of their vision both deeper into the ultraviolet and further into the red.

  1. Volatiles in glasses from the HSDP2 drill core

    NASA Astrophysics Data System (ADS)

    Seaman, Caroline; Sherman, Sarah Bean; Garcia, Michael O.; Baker, Michael B.; Balta, Brian; Stolper, Edward

    2004-09-01

    H2O, CO2, S, Cl, and F concentrations are reported for 556 glasses from the submarine section of the 1999 phase of HSDP drilling in Hilo, Hawaii, providing a high-resolution record of magmatic volatiles over ˜200 kyr of a Hawaiian volcano's lifetime. Glasses range from undegassed to having lost significant volatiles at near-atmospheric pressure. Nearly all hyaloclastite glasses are degassed, compatible with formation from subaerial lavas that fragmented on entering the ocean and were transported by gravity flows down the volcano flank. Most pillows are undegassed, indicating submarine eruption. The shallowest pillows and most massive lavas are degassed, suggesting formation by subaerial flows that penetrated the shoreline and flowed some distance under water. Some pillow rim glasses have H2O and S contents indicating degassing but elevated CO2 contents that correlate with depth in the core; these tend to be more fractionated and could have formed by mixing of degassed, fractionated magmas with undegassed magmas during magma chamber overturn or by resorption of rising CO2-rich bubbles by degassed magmas. Intrusive glasses are undegassed and have CO2 contents similar to adjacent pillows, indicating intrusion shallow in the volcanic edifice. Cl correlates weakly with H2O and S, suggesting loss during low-pressure degassing, although most samples appear contaminated by seawater-derived components. F behaves as an involatile incompatible element. Fractionation trends were modeled using MELTS. Degassed glasses require fractionation at p? ≈ 5-10 bars. Undegassed low-SiO2 glasses require fractionation at p? ≈ 50 bars. Undegassed and partially degassed high-SiO2 glasses can be modeled by coupled crystallization and degassing. Eruption depths of undegassed pillows can be calculated from their volatile contents assuming vapor saturation. The amount of subsidence can be determined from the difference between this depth and the sample's depth in the core. Assuming

  2. Feasibility of Augmented Reality in Clinical Simulations: Using Google Glass With Manikins.

    PubMed

    Chaballout, Basil; Molloy, Margory; Vaughn, Jacqueline; Brisson Iii, Raymond; Shaw, Ryan

    2016-03-07

    Studies show that students who use fidelity-based simulation technology perform better and have higher retention rates than peers who learn in traditional paper-based training. Augmented reality is increasingly being used as a teaching and learning tool in a continual effort to make simulations more realistic for students. The aim of this project was to assess the feasibility and acceptability of using augmented reality via Google Glass during clinical simulation scenarios for training health science students. Students performed a clinical simulation while watching a video through Google Glass of a patient actor simulating respiratory distress. Following participation in the scenarios students completed two surveys and were questioned if they would recommend continued use of this technology in clinical simulation experiences. We were able to have students watch a video in their field of vision of a patient who mimicked the simulated manikin. Students were overall positive about the implications for being able to view a patient during the simulations, and most students recommended using the technology in the future. Overall, students reported perceived realism with augmented reality using Google Glass. However, there were technical and usability challenges with the device. As newer portable and consumer-focused technologies become available, augmented reality is increasingly being used as a teaching and learning tool to make clinical simulations more realistic for health science students. We found Google Glass feasible and acceptable as a tool for augmented reality in clinical simulations.

  3. U-based metallic glasses with superior glass forming ability

    NASA Astrophysics Data System (ADS)

    Xu, Hongyang; Ke, Haibo; Huang, Huogen; Zhang, Pengguo; Pu, Zhen; Zhang, Pei; Liu, Tianwei

    2018-02-01

    By using Al as the third and B as the fourth but minor alloying elements for the U66.7Co33.3 basic metallic glass, a series of U-Co-Al(-B) alloys were designed. The quaternary U-Co-Al-B alloys exhibit significantly improved glass-forming ability (GFA) than previously reported U-based metallic glasses. Low fragility (∼24) is found for these new U-based metallic glasses. The improvement in GFA would result from denser atomic packing in the undercooled liquids due to the presence of small B atoms. Some U-Co-Al(-B) glasses showed corrosion resistance comparable to that of U64Co34Al2 glass, known for premium anti-corrosive performance among the unveiled U-based glasses.

  4. Edit distance for marked point processes revisited: An implementation by binary integer programming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirata, Yoshito; Aihara, Kazuyuki

    2015-12-15

    We implement the edit distance for marked point processes [Suzuki et al., Int. J. Bifurcation Chaos 20, 3699–3708 (2010)] as a binary integer program. Compared with the previous implementation using minimum cost perfect matching, the proposed implementation has two advantages: first, by using the proposed implementation, we can apply a wide variety of software and hardware, even spin glasses and coherent ising machines, to calculate the edit distance for marked point processes; second, the proposed implementation runs faster than the previous implementation when the difference between the numbers of events in two time windows for a marked point process ismore » large.« less

  5. Evolutionary replacement of UV vision by violet vision in fish.

    PubMed

    Tada, Takashi; Altun, Ahmet; Yokoyama, Shozo

    2009-10-13

    The vertebrate ancestor possessed ultraviolet (UV) vision and many species have retained it during evolution. Many other species switched to violet vision and, then again, some avian species switched back to UV vision. These UV and violet vision are mediated by short wavelength-sensitive (SWS1) pigments that absorb light maximally (lambda(max)) at approximately 360 and 390-440 nm, respectively. It is not well understood why and how these functional changes have occurred. Here, we cloned the pigment of scabbardfish (Lepidopus fitchi) with a lambda(max) of 423 nm, an example of violet-sensitive SWS1 pigment in fish. Mutagenesis experiments and quantum mechanical/molecular mechanical (QM/MM) computations show that the violet-sensitivity was achieved by the deletion of Phe-86 that converted the unprotonated Schiff base-linked 11-cis-retinal to a protonated form. The finding of a violet-sensitive SWS1 pigment in scabbardfish suggests that many other fish also have orthologous violet pigments. The isolation and comparison of such violet and UV pigments in fish living in different ecological habitats will open an unprecedented opportunity to elucidate not only the molecular basis of phenotypic adaptations, but also the genetics of UV and violet vision.

  6. Pressure Induced Liquid-to-Liquid Transition in Zr-based Supercooled Melts and Pressure Quenched Glasses.

    PubMed

    Dmowski, W; Gierlotka, S; Wang, Z; Yokoyama, Y; Palosz, B; Egami, T

    2017-07-26

    Through high-energy x-ray diffraction and atomic pair density function analysis we find that Zr-based metallic alloy, heated to the supercooled liquid state under hydrostatic pressure and then quenched to room temperature, exhibits a distinct glassy structure. The PDF indicates that the Zr-Zr distances in this glass are significantly reduced compared to those quenched without pressure. Annealing at the glass transition temperature at ambient pressure reverses structural changes and the initial glassy state is recovered. This result suggests that pressure causes a liquid-to-liquid phase transition in this metallic alloy supercooled melt. Such a pressure induced transition is known for covalent liquids, but has not been observed for metallic liquids. The High Pressure Quenched glasses are stable in ambient conditions after decompression.

  7. Cues to viewing distance for stereoscopic depth constancy.

    PubMed

    Glennerster, A; Rogers, B J; Bradshaw, M F

    1998-01-01

    A veridical estimate of viewing distance is required in order to determine the metric structure of objects from binocular stereopsis. One example of a judgment of metric structure, which we used in our experiment, is the apparently circular cylinder task (E B Johnston, 1991 Vision Research 31 1351-1360). Most studies report underconstancy in this task when the stimulus is defined purely by binocular disparities. We examined the effect of two factors on performance: (i) the richness of the cues to viewing distance (using either a naturalistic setting with many cues to viewing distance or a condition in which the room and the monitors were obscured from view), and (ii) the range of stimulus disparities (cylinder depths) presented during an experimental run. We tested both experienced subjects (who had performed the task many times before under full-cue conditions) and naïve subjects. Depth constancy was reduced for the naïve subjects (from 62% to 46%) when the position of the monitors was obscured. Under similar conditions, the experienced subjects showed no reduction in constancy. In a second experiment, using a forced-choice method of constant stimuli, we found that depth constancy was reduced from 64% to 23% in naïve subjects and from 77% to 55% in experienced subjects when the same set of images was presented at all viewing distances rather than using a set of stimulus disparities proportional to the correct setting. One possible explanation of these results is that, under reduced-cue conditions, the range of disparities presented is used by the visual system as a cue to viewing distance.

  8. Investigation of gamma radiation induced changes in local structure of borosilicate glass by TDPAC and EXAFS

    NASA Astrophysics Data System (ADS)

    Kumar, Ashwani; Nayak, C.; Rajput, P.; Mishra, R. K.; Bhattacharyya, D.; Kaushik, C. P.; Tomar, B. S.

    2016-12-01

    Gamma radiation induced changes in local structure around the probe atom (Hafnium) were investigated in sodium barium borosilicate (NBS) glass, used for immobilization of high level liquid waste generated from the reprocessing plant at Trombay, Mumbai. The (NBS) glass was doped with 181Hf as a probe for time differential perturbed angular correlation (TDPAC) spectroscopy studies, while for studies using extended X-ray absorption fine structure (EXAFS) spectroscopy, the same was doped with 0.5 and 2 % (mole %) hafnium oxide. The irradiated as well as un-irradiated glass samples were studied by TDPAC and EXAFS techniques to obtain information about the changes (if any) around the probe atom due to gamma irradiation. TDPAC spectra of unirradiated and irradiated glasses were similar and reminescent of amorphous materials, indicating negligible effect of gamma radiation on the microstructure around Hafnium probe atom, though the quaqdrupole interaction frequency ( ω Q) and asymmetry parameter ( η) did show a marginal decrease in the irradiated glass compared to that in the unirradiated glass. EXAFS measurements showed a slight decrease in the Hf-O bond distance upon gamma irradiation of Hf doped NBS glass indicating densification of the glass matrix, while the cordination number around hafnium remains unchanged.

  9. Vision Care and the Nation's Children.

    ERIC Educational Resources Information Center

    American Optometric Association, St. Louis, MO.

    Aspects of vision and vision care considered are the following: extent and types of vision defects of American children; importance of vision care in pre-school years, elementary, and secondary school and beyond; and manpower resources in vision care today, the extent of vision testing and care, special problem areas, and governmental support.…

  10. Changes in vision related quality of life in patients with diabetic macular edema: ranibizumab or laser treatment?

    PubMed

    Turkoglu, Elif Betul; Celık, Erkan; Aksoy, Nilgun; Bursalı, Ozlem; Ucak, Turgay; Alagoz, Gursoy

    2015-01-01

    To compare the changes in vision related quality of life (VR-QoL) in patients with diabetic macular edema (DME) undergoing intravitreal ranibizumab (IVR) injection or focal/grid laser. In this prospective study, 70 patients with clinically significant macular edema (CSME) were randomized to undergo IVR injection (n=35) and focal/grid laser (n=35). If necessary, the laser or ranibizumab injections were repeated. Distance and near visual acuities, central retinal thickness (CRT) and The 25-item Visual Function Questionnaire (VFQ-25) were used to measure the effectiveness of treatments and VR-QoL before and after 6 months following IVR or laser treatment. The demographic and clinical findings before the treatments were similar in both main groups. The improvements in distance and near visual acuities were higher in IVR group than the laser group (p<0.01). The reduction in CRT in IVR group was higher than that in laser treatment group (p<0.01). In both groups, the VFQ-25 composite score tended to improve from baseline to 6 months. And at 6th month, the changes in composite score were significantly higher in IVR group than in laser group (p<0.05). The improvements in overall composite scores were 6.3 points for the IVR group compared with 3.0 points in the laser group. Patients treated with IVR and laser had large improvements in composite scores, general vision, near and distance visual acuities in VFQ-25 at 6 months, in comparison with baseline scores, and also mental health subscale in IVR group. Our study revealed that IVR improved not only visual acuity or CRT, but also vision related quality of life more than laser treatment in DME. And these patient-reported outcomes may play an important role in the treatment choice in DME for clinicians. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Distance education but beyond: "meLearning"--what if the impossible isn't?

    PubMed

    Hodgins, Wayne

    2007-01-01

    It's not the physical distance between teachers and learners that is the problem but the gap between what all of us as learners need and what those who supply the education, training, and learning have to offer. Mass-produced education for the masses will give way to massively customized learning with contributions from all. While the scope of such an endeavor appears staggering, the dream of adaptive, personalized "meLearning" for every person every day, and thus the brightest future ever imagined, lies immediately in front of us and within our grasp. The vision for a future world state where every person experiences personalized learning every day is clear, but it has arrived prematurely, is inequitably distributed, and remains unseen by most. Moreover, and as has been common in the history of conditions preceding such mass revolutions, the existing organizations and institution stand in stark contrast to this vision and, in many ways, oppose it. All quite predictable and understandable. However, the status quo is no longer an option. The distance between the supply side of the equation (solutions offered) and the demand side (demands and needs) is disproportionately large. Change is inevitable, and is increasingly demanded by all involved. If you have not done so already, it is time to start imagining what our world would be like if we increased the effectiveness of learning for everyone, all the time, by customizing the learning to fit each individual person and situation. Imagine if the impossible isn't! Many others already have. This future is ours for the choosing if we can muster the courage to ignite the transformation from vision to reality by simply imagining that this bright future is now possible and beginning to shape its design and implementation.

  12. Federal regulation of vision enhancement devices for normal and abnormal vision

    NASA Astrophysics Data System (ADS)

    Drum, Bruce

    2006-09-01

    The Food and Drug Administration (FDA) evaluates the safety and effectiveness of medical devices and biological products as well as food and drugs. The FDA defines a device as a product that is intended, by physical means, to diagnose, treat, or prevent disease, or to affect the structure or function of the body. All vision enhancement devices fulfill this definition because they are intended to affect a function (vision) of the body. In practice, however, FDA historically has drawn a distinction between devices that are intended to enhance low vision as opposed to normal vision. Most low vision aids are therapeutic devices intended to compensate for visual impairment, and are actively regulated according to their level of risk to the patient. The risk level is usually low (e.g. Class I, exempt from 510(k) submission requirements for magnifiers that do not touch the eye), but can be as high as Class III (requiring a clinical trial and Premarket Approval (PMA) application) for certain implanted and prosthetic devices (e.g. intraocular telescopes and prosthetic retinal implants). In contrast, the FDA usually does not actively enforce its regulations for devices that are intended to enhance normal vision, are low risk, and do not have a medical intended use. However, if an implanted or prosthetic device were developed for enhancing normal vision, the FDA would likely decide to regulate it actively, because its intended use would entail a substantial medical risk to the user. Companies developing such devices should contact the FDA at an early stage to clarify their regulatory status.

  13. Peripheral Vision of Youths with Low Vision: Motion Perception, Crowding, and Visual Search

    PubMed Central

    Tadin, Duje; Nyquist, Jeffrey B.; Lusk, Kelly E.; Corn, Anne L.; Lappin, Joseph S.

    2012-01-01

    Purpose. Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. Methods. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10–17) and low vision (n = 24, ages 9–18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. Results. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Conclusions. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function. PMID:22836766

  14. Correlation Functions and Glass Structure

    NASA Astrophysics Data System (ADS)

    Chergui, Y.; Nehaoua, N.; Telghemti, B.; Guemid, S.; Deraddji, N. E.; Belkhir, H.; Mekki, D. E.

    2011-04-01

    This work presents the use of molecular dynamics (MD) and the code of Dl Poly, in order to study the structure of fluoride glass after melting and quenching. We are realized the processing phase liquid-phase, simulating rapid quenching at different speeds to see the effect of quenching rate on the operation of the devitrification. This technique of simulation has become a powerful tool for investigating the microscopic behaviour of matter as well as for calculating macroscopic observable quantities. As basic results, we calculated the interatomic distance, angles and statistics, which help us to know the geometric form and the structure of PbF2. These results are in experimental agreement to those reported in literature.

  15. Low Vision Tips

    MedlinePlus

    ... this page: https://medlineplus.gov/lowvision.html MedlinePlus: Low Vision Tips We are sorry. MedlinePlus no longer maintains the For Low Vision Users page. You will still find health resources ...

  16. Ocular injuries from exploding glass-bottled Coca-Cola® drinks in Port Harcourt, Nigeria.

    PubMed

    Pedro-Egbe, Chinyere Nnenne; Ejimadu, Chibuike Sydney; Nwachukwu, Henrietta

    2011-01-01

    Eye injuries and subsequent loss of vision from the glass and caps of exploding pressurized bottled drinks have been well reported, and as a result most developed countries now use mainly plastic bottles. In Nigeria, however, most drinks are still sold in glass bottles and ocular injuries from this source are therefore not uncommon. To retrospectively analyze ocular injuries resulting from exploding glass-bottled Coca-Cola® and propose ways of eliminating such injuries in future. Eye Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. The medical records of all cases of ocular injury that presented at the Eye Clinic of the University of Port Harcourt Teaching Hospital over a 5-year period (January 2006 to December 2010) were retrieved and relevant data including age, sex, occupation, events surrounding bottle explosion, and type of ocular injury sustained were extracted. A total of 426 cases of ocular injuries was seen during the period under review. There were 335 (78.6%) males and 91 (21.4%) females. Six patients had ocular injury from exploding glass-bottled Coca-Cola®, giving an incidence of 1.4%. The presenting visual acuities (VA) were light perception (2 cases), counting fingers (2 cases), and 1 VA of 6/24 and 1 VA of 6/12. There were 4 (66.7%) cases of corneoscleral laceration with uveal prolapse and 1 case of total hyphema. Because pressurized glass-bottles can explode with normal handling, legislation to ban the use of glass containers for bottling carbonated drinks will go a long way to reducing ocular morbidity from this source. Plastic bottles should be introduced as an alternative.

  17. DISTANCES TO DARK CLOUDS: COMPARING EXTINCTION DISTANCES TO MASER PARALLAX DISTANCES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foster, Jonathan B.; Jackson, James M.; Stead, Joseph J.

    We test two different methods of using near-infrared extinction to estimate distances to dark clouds in the first quadrant of the Galaxy using large near-infrared (Two Micron All Sky Survey and UKIRT Infrared Deep Sky Survey) surveys. Very long baseline interferometry parallax measurements of masers around massive young stars provide the most direct and bias-free measurement of the distance to these dark clouds. We compare the extinction distance estimates to these maser parallax distances. We also compare these distances to kinematic distances, including recent re-calibrations of the Galactic rotation curve. The extinction distance methods agree with the maser parallax distancesmore » (within the errors) between 66% and 100% of the time (depending on method and input survey) and between 85% and 100% of the time outside of the crowded Galactic center. Although the sample size is small, extinction distance methods reproduce maser parallax distances better than kinematic distances; furthermore, extinction distance methods do not suffer from the kinematic distance ambiguity. This validation gives us confidence that these extinction methods may be extended to additional dark clouds where maser parallaxes are not available.« less

  18. Glass-silicon column

    DOEpatents

    Yu, Conrad M.

    2003-12-30

    A glass-silicon column that can operate in temperature variations between room temperature and about 450.degree. C. The glass-silicon column includes large area glass, such as a thin Corning 7740 boron-silicate glass bonded to a silicon wafer, with an electrode embedded in or mounted on glass of the column, and with a self alignment silicon post/glass hole structure. The glass/silicon components are bonded, for example be anodic bonding. In one embodiment, the column includes two outer layers of silicon each bonded to an inner layer of glass, with an electrode imbedded between the layers of glass, and with at least one self alignment hole and post arrangement. The electrode functions as a column heater, and one glass/silicon component is provided with a number of flow channels adjacent the bonded surfaces.

  19. Features of the Vision of Elderly Pedestrians when Crossing a Road.

    PubMed

    Matsui, Yasuhiro; Oikawa, Shoko; Aoki, Yoshio; Sekine, Michiaki; Mitobe, Kazutaka

    2014-11-01

    The present study clarifies the mechanism by which an accident occurs when an elderly pedestrian crosses a road in front of a car, focusing on features of the central and peripheral vision of elderly pedestrians who are judging when it is safe to cross the road. For the pedestrian's central visual field, we investigated the effect of age on the timing judgment using an actual car. The results for daytime conditions indicate that the elderly pedestrians tended to make later judgments of when they crossed the road from the right side of the driver's view at high car velocities. At night, for a car with its headlights on high beam, the average car-pedestrian distances of elderly pedestrians on the left side of the driver's view were significantly longer than those of young pedestrians at velocities of 20 and 40 km/h. The eyesight of the elderly pedestrians during the day did not affect the timing judgment of crossing a road. At night, for a car with its headlights on either high or low beam, the average car-pedestrian distances of elderly pedestrians having good eyesight were longer than those of elderly pedestrians having poor eyesight, for all car velocities. The color of the car body in the central visual field did not affect the timing judgment of elderly pedestrians crossing the road. Meanwhile, the car-body color in the elderly pedestrian's peripheral vision strongly affected the pedestrian's awareness of the car.

  20. Two-dimensional (2D) displacement measurement of moving objects using a new MEMS binocular vision system

    NASA Astrophysics Data System (ADS)

    Di, Si; Lin, Hui; Du, Ruxu

    2011-05-01

    Displacement measurement of moving objects is one of the most important issues in the field of computer vision. This paper introduces a new binocular vision system (BVS) based on micro-electro-mechanical system (MEMS) technology. The eyes of the system are two microlenses fabricated on a substrate by MEMS technology. The imaging results of two microlenses are collected by one complementary metal-oxide-semiconductor (CMOS) array. An algorithm is developed for computing the displacement. Experimental results show that as long as the object is moving in two-dimensional (2D) space, the system can effectively estimate the 2D displacement without camera calibration. It is also shown that the average error of the displacement measurement is about 3.5% at different object distances ranging from 10 cm to 35 cm. Because of its low cost, small size and simple setting, this new method is particularly suitable for 2D displacement measurement applications such as vision-based electronics assembly and biomedical cell culture.

  1. Vision Screening of Ophthalmic Nursing Staff in a Tertiary Eye Care Hospital

    PubMed Central

    Khan, Ruhi A.; Souru, Ches; Vaghese, Sejo; Yasir, Ziaul; Khandekar, Rajiv

    2017-01-01

    Objectives This study aimed to evaluate ocular healthcare-seeking behaviours and vision screening outcomes of nursing staff at a tertiary eye care hospital. Methods This study was conducted between April and September 2016 among all 500 nurses employed at the King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia. Data were collected on age, gender, use of visual aids, the presence of diabetes, a history of refractive surgery and date of last ocular health check-up. Participants were tested using a handheld Spot™ Vision Screener (Welch Allyn Inc., Skaneateles Falls, New York, USA). Results A total of 150 nurses participated in the study (response rate: 30.0%). The mean age was 41.2 ± 8.9 years old. Distance spectacles, reading spectacles and both types of spectacles were used by 37 (24.7%), 32 (21.3%) and 10 (6.7%) nurses, respectively. A total of 58 nurses (38.7%) failed the vision screening test. Visual defects were detected for the first time in 13 nurses (8.7%). With regards to regular eye checkups, 77 participants (51.3%) reported acceptable ocular healthcare-seeking behaviours; this factor was significantly associated with age and the use of visual aids (P <0.01 each). Conclusion A high proportion of participants failed the vision screening tests and only half displayed good ocular healthcare-seeking behaviours. This is concerning as ophthalmic nurses are likely to face fewer barriers to eye care services than the general population. PMID:28417032

  2. Do reading additions improve reading in pre-presbyopes with low vision?

    PubMed

    Alabdulkader, Balsam; Leat, Susan

    2012-09-01

    This study compared three different methods of determining a reading addition and the possible improvement on reading performance in children and young adults with low vision. Twenty-eight participants with low vision, aged 8 to 32 years, took part in the study. Reading additions were determined with (a) a modified Nott dynamic retinoscopy, (b) a subjective method, and (c) an age-based formula. Reading performance was assessed with MNREAD-style reading charts at 12.5 cm, with and without each reading addition in random order. Outcome measures were reading speed, critical print size, MNREAD threshold, and the area under the reading speed curve. For the whole group, there was no significant improvement in reading performance with any of the additions. When participants with normal accommodation at 12.5 cm were excluded, the area under the reading speed curve was significantly greater with all reading additions compared with no addition (p = 0.031, 0.028, and 0.028, respectively). Also, the reading acuity threshold was significantly better with all reading additions compared with no addition (p = 0.014, 0.030, and 0.036, respectively). Distance and near visual acuity, age, and contrast sensitivity did not predict improvement with a reading addition. All, but one, of the participants who showed a significant improvement in reading with an addition had reduced accommodation. A reading addition may improve reading performance for young people with low vision and should be considered as part of a low vision assessment, particularly when accommodation is reduced.

  3. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    PubMed Central

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  4. Glass sealing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brow, R.K.; Kovacic, L.; Chambers, R.S.

    1996-04-01

    Hernetic glass sealing technologies developed for weapons component applications can be utilized for the design and manufacture of fuel cells. Design and processing of of a seal are optimized through an integrated approach based on glass composition research, finite element analysis, and sealing process definition. Glass sealing procedures are selected to accommodate the limits imposed by glass composition and predicted calculations.

  5. Leading Vision

    ERIC Educational Resources Information Center

    Fawcett, Gay

    2004-01-01

    The current educational landscape makes it imperative that a vision statement become more than a fine-sounding statement that is laminated, hung on the wall, and quickly forgotten. If educators do not have a clear image of the future they wish to create, then someone will be ready to create it for them. But with a clear vision of the future, a…

  6. Optimizing the depth of field for short object distance of capsule endoscope

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Mang; Huang, Shih-Wei; Su, Wei-Kai; Feng, Han-Ming; Chen, Zhao-Yu; Wu, Hsien-Ming; Kuo, Yi-Ting

    2008-02-01

    Research of depth of field (DOF) for capsule endoscope is important for the reason that the shapes of the object plane of the intestine or the stomach are curve surfaces of "<" shape or "c" shape. The depth of field is dependent on following factors: focal length, circle of confusion, aperture, and subject distance. The first three factors are improved for wide view angle in prior paper and determined by the chosen sensor, and it is not going against depth of field. Last factor, subject distance, is the more freedom to enlarge the depth of field. However, depth of field is the range between near depth of field limit and far depth of field limit that are acceptably sharp. The fraction of the depth of field behind the focus is always large then the one in front of the focus distance. The depth of field does change with object distance, and it is increasing as object distance is increasing. But the object distance of the design for capsule endoscope is short. The object distance setting in front of the dorm is more efficient to use the depth of field than the one setting at the dome top. Therefore there is an appropriate design of object distance to make depth of field be used efficiently to inspect curve surface of intestine and stomach. The more vision information of inspect digestive system is get and is compared easily to diagnose patients' condition under wide and efficient range of depth of field.

  7. Analysis of early medieval glass beads - Glass in the transition period

    NASA Astrophysics Data System (ADS)

    Šmit, Žiga; Knific, Timotej; Jezeršek, David; Istenič, Janka

    2012-05-01

    Glass beads from graves excavated in Slovenia and dated archaeologically to the 7th-10th century AD were analysed by the combined PIXE-PIGE method. The results indicate two groups of glass; natron glass made in the Roman tradition and glass made with alkalis from the ash of halophytic plants, which gradually replaced natron glass after c. 800 AD. The alkalis used in the second group of glass seem to be in close relation to a variant of the Venetian white glass that appeared several centuries later. The origin of this glass may be traced to glass production in Mesopotamia and around the Aral Sea. All the mosaic beads with eye decoration, as well as most of the drawn-segmented and drawn-cut beads analysed, are of plant-ash glass, which confirms their supposed oriental origin.

  8. Glass Artworks

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Several NASA technologies have played part in growth and cost containment of studio glass art, among them a foam type insulation developed to meet a need for lightweight material that would reduce flame spread in aircraft fire. Foam comes in several forms and is widely used by glass artists, chiefly as an insulator for the various types of ovens used in glass working. Another Spinoff is alumina crucibles to contain molten glass. Before alumina crucibles were used, glass tanks were made of firebrick which tended to erode under high temperatures and cause impurities; this not only improved quality but made the process more cost effective. One more NASA technology that found its way into glass art working is a material known as graphite board, a special form of graphite originally developed for rocket motor applications. This graphite is used to exact compound angles and creates molds for poured glass artworks of dramatic design.

  9. Biofeedback for Better Vision

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Biofeedtrac, Inc.'s Accommotrac Vision Trainer, invented by Dr. Joseph Trachtman, is based on vision research performed by Ames Research Center and a special optometer developed for the Ames program by Stanford Research Institute. In the United States, about 150 million people are myopes (nearsighted), who tend to overfocus when they look at distant objects causing blurry distant vision, or hyperopes (farsighted), whose vision blurs when they look at close objects because they tend to underfocus. The Accommotrac system is an optical/electronic system used by a doctor as an aid in teaching a patient how to contract and relax the ciliary body, the focusing muscle. The key is biofeedback, wherein the patient learns to control a bodily process or function he is not normally aware of. Trachtman claims a 90 percent success rate for correcting, improving or stopping focusing problems. The Vision Trainer has also proved effective in treating other eye problems such as eye oscillation, cross eyes, and lazy eye and in professional sports to improve athletes' peripheral vision and reaction time.

  10. An update on the characteristics of patients attending the Kooyong Low Vision Clinic.

    PubMed

    Chong, Mae Fa; Jackson, A Jonathan; Wolffsohn, James S; Bentley, Sharon A

    2016-11-01

    Since 1972, the Australian College of Optometry has worked in partnership with Vision Australia to provide multidisciplinary low-vision care at the Kooyong Low Vision Clinic. In 1999, Wolffsohn and Cochrane reported on the demographic characteristics of patients attending Kooyong. Sixteen years on, the aim of this study is to review the demographics of the Kooyong patient cohort and prescribing patterns. Records of all new patients (n = 155) attending the Kooyong Low Vision Clinic for optometry services between April and September 2012 were retrospectively reviewed. Median age was 84.3 years (range 7.7 to 98.1 years) with 59 per cent female. The majority of patients presented with late-onset degenerative pathology, 49 per cent with a primary diagnosis of age-related macular degeneration. Many (47.1 per cent) lived with their families. Mean distance visual acuity was 0.57 ± 0.47 logMAR or approximately 6/24. The median spectacle-corrected near visual acuity was N8 (range N3 to worse than N80). Fifty patients (32.3 per cent) were prescribed new spectacles, 51 (32.9 per cent) low vision aids and five (8.3 per cent) were prescribed electronic magnification devices. Almost two-thirds (63.9 per cent) were referred for occupational therapy management and 12.3 per cent for orientation and mobility services. The profile of patients presenting for low-vision services at Kooyong is broadly similar to that identified in 1999. Outcomes appear to be similar, aside from an expected increase in electronic devices and technological solutions; however, the nature of services is changing, as treatments for ocular diseases advance and assistive technology develops and becomes more accessible. Alongside the aging population and age-related ocular disease being the predominant cause of low vision in Australia, the health-funding landscape is becoming more restrictive. The challenge for the future will be to provide timely, high-quality care in an economically efficient model. © 2016

  11. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment.

    PubMed

    Allen, Peter M; Latham, Keziah; Mann, David L; Ravensbergen, Rianne H J C; Myint, Joy

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle, while standing, toward a regulation target placed at the end of a 10 m shooting range. Cambridge simulation glasses were used to simulate six different levels of VI. Visual acuity (VA) and contrast sensitivity (CS) were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual's average score in every level of simulated VI and normalizing this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving 'expected' or 'below expected' shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR) is conservative, maximizing the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not actually have an impairment that impacts performance in the sport. An

  12. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment

    PubMed Central

    Allen, Peter M.; Latham, Keziah; Mann, David L.; Ravensbergen, Rianne H. J. C.; Myint, Joy

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle, while standing, toward a regulation target placed at the end of a 10 m shooting range. Cambridge simulation glasses were used to simulate six different levels of VI. Visual acuity (VA) and contrast sensitivity (CS) were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual’s average score in every level of simulated VI and normalizing this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving ‘expected’ or ‘below expected’ shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR) is conservative, maximizing the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not actually have an impairment that impacts performance in the

  13. Representational Distance Learning for Deep Neural Networks

    PubMed Central

    McClure, Patrick; Kriegeskorte, Nikolaus

    2016-01-01

    Deep neural networks (DNNs) provide useful models of visual representational transformations. We present a method that enables a DNN (student) to learn from the internal representational spaces of a reference model (teacher), which could be another DNN or, in the future, a biological brain. Representational spaces of the student and the teacher are characterized by representational distance matrices (RDMs). We propose representational distance learning (RDL), a stochastic gradient descent method that drives the RDMs of the student to approximate the RDMs of the teacher. We demonstrate that RDL is competitive with other transfer learning techniques for two publicly available benchmark computer vision datasets (MNIST and CIFAR-100), while allowing for architectural differences between student and teacher. By pulling the student's RDMs toward those of the teacher, RDL significantly improved visual classification performance when compared to baseline networks that did not use transfer learning. In the future, RDL may enable combined supervised training of deep neural networks using task constraints (e.g., images and category labels) and constraints from brain-activity measurements, so as to build models that replicate the internal representational spaces of biological brains. PMID:28082889

  14. Representational Distance Learning for Deep Neural Networks.

    PubMed

    McClure, Patrick; Kriegeskorte, Nikolaus

    2016-01-01

    Deep neural networks (DNNs) provide useful models of visual representational transformations. We present a method that enables a DNN (student) to learn from the internal representational spaces of a reference model (teacher), which could be another DNN or, in the future, a biological brain. Representational spaces of the student and the teacher are characterized by representational distance matrices (RDMs). We propose representational distance learning (RDL), a stochastic gradient descent method that drives the RDMs of the student to approximate the RDMs of the teacher. We demonstrate that RDL is competitive with other transfer learning techniques for two publicly available benchmark computer vision datasets (MNIST and CIFAR-100), while allowing for architectural differences between student and teacher. By pulling the student's RDMs toward those of the teacher, RDL significantly improved visual classification performance when compared to baseline networks that did not use transfer learning. In the future, RDL may enable combined supervised training of deep neural networks using task constraints (e.g., images and category labels) and constraints from brain-activity measurements, so as to build models that replicate the internal representational spaces of biological brains.

  15. Reading performance with low-vision aids and vision-related quality of life after macular translocation surgery in patients with age-related macular degeneration.

    PubMed

    Nguyen, Nhung X; Besch, Dorothea; Bartz-Schmidt, Karl; Gelisken, Faik; Trauzettel-Klosinski, Susanne

    2007-12-01

    The aim of the present study was to evaluate the power of magnification required, reading performance with low-vision aids and vision-related quality of life with reference to reading ability and ability to carry out day-to-day activities in patients after macular translocation. This study included 15 patients who had undergone macular translocation with 360-degree peripheral retinectomy. The mean length of follow-up was 19.2 +/- 10.8 months (median 11 months). At the final examination, the impact of visual impairment on reading ability and quality of life was assessed according to a modified 9-item questionnaire in conjunction with a comprehensive clinical examination, which included assessment of best corrected visual acuity (BCVA), the magnification power required for reading, use of low-vision aids and reading speed. Patients rated the extent to which low vision restricted their ability to read and participate in other activities that affect quality of life. Responses were scored on a scale of 1.0 (optimum self-evaluation) to 5.0 (very poor). In the operated eye, overall mean postoperative BCVA (distance) was not significantly better than mean preoperative BCVA (0.11 +/- 0.06 and 0.15 +/- 0.08, respectively; p = 0.53). However, 53% of patients reported a subjective increase in visual function after treatment. At the final visit, the mean magnification required was x 7.7 +/- 6.7. A total of 60% of patients needed optical magnifiers for reading and in 40% of patients closed-circuit TV systems were necessary. All patients were able to read newspaper print using adapted low-vision aids at a mean reading speed of 71 +/- 40 words per minute. Mean self-reported scores were 3.2 +/- 1.1 for reading, 2.5 +/- 0.7 for day-to-day activities and 2.7 +/- 3.0 for outdoor walking and using steps or stairs. Patients' levels of dependency were significantly correlated with scores for reading (p = 0.01), day-to-day activities (p < 0.001) and outdoor walking and using steps (p = 0

  16. Monocular Vision-Based Underwater Object Detection

    PubMed Central

    Zhang, Zhen; Dai, Fengzhao; Bu, Yang; Wang, Huibin

    2017-01-01

    In this paper, we propose an underwater object detection method using monocular vision sensors. In addition to commonly used visual features such as color and intensity, we investigate the potential of underwater object detection using light transmission information. The global contrast of various features is used to initially identify the region of interest (ROI), which is then filtered by the image segmentation method, producing the final underwater object detection results. We test the performance of our method with diverse underwater datasets. Samples of the datasets are acquired by a monocular camera with different qualities (such as resolution and focal length) and setups (viewing distance, viewing angle, and optical environment). It is demonstrated that our ROI detection method is necessary and can largely remove the background noise and significantly increase the accuracy of our underwater object detection method. PMID:28771194

  17. Glass binder development for a glass-bonded sodalite ceramic waste form

    NASA Astrophysics Data System (ADS)

    Riley, Brian J.; Vienna, John D.; Frank, Steven M.; Kroll, Jared O.; Peterson, Jacob A.; Canfield, Nathan L.; Zhu, Zihua; Zhang, Jiandong; Kruska, Karen; Schreiber, Daniel K.; Crum, Jarrod V.

    2017-06-01

    This paper discusses work to develop Na2O-B2O3-SiO2 glass binders for immobilizing LiCl-KCl eutectic salt waste in a glass-bonded sodalite waste form following electrochemical reprocessing of used metallic nuclear fuel. Here, five new glasses with ∼20 mass% Na2O were designed to generate waste forms with high sodalite. The glasses were then used to produce ceramic waste forms with a surrogate salt waste. The waste forms made using these new glasses were formulated to generate more sodalite than those made with previous baseline glasses for this type of waste. The coefficients of thermal expansion for the glass phase in the glass-bonded sodalite waste forms made with the new binder glasses were closer to the sodalite phase in the critical temperature region near and below the glass transition temperature than previous binder glasses used. These improvements should result in lower probability of cracking in the full-scale monolithic ceramic waste form, leading to better long-term chemical durability.

  18. Glass binder development for a glass-bonded sodalite ceramic waste form

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, Brian J.; Vienna, John D.; Frank, Steven M.

    This paper discusses work to develop Na 2O-B 2O 3-SiO 2 glass binders for immobilizing LiCl-KCl eutectic salt waste in a glass-bonded sodalite waste form following electrochemical reprocessing of used metallic nuclear fuel. In this paper, five new glasses with ~20 mass% Na 2O were designed to generate waste forms with high sodalite. The glasses were then used to produce ceramic waste forms with a surrogate salt waste. The waste forms made using these new glasses were formulated to generate more sodalite than those made with previous baseline glasses for this type of waste. The coefficients of thermal expansion formore » the glass phase in the glass-bonded sodalite waste forms made with the new binder glasses were closer to the sodalite phase in the critical temperature region near and below the glass transition temperature than previous binder glasses used. Finally, these improvements should result in lower probability of cracking in the full-scale monolithic ceramic waste form, leading to better long-term chemical durability.« less

  19. Glass binder development for a glass-bonded sodalite ceramic waste form

    DOE PAGES

    Riley, Brian J.; Vienna, John D.; Frank, Steven M.; ...

    2017-06-01

    This paper discusses work to develop Na 2O-B 2O 3-SiO 2 glass binders for immobilizing LiCl-KCl eutectic salt waste in a glass-bonded sodalite waste form following electrochemical reprocessing of used metallic nuclear fuel. In this paper, five new glasses with ~20 mass% Na 2O were designed to generate waste forms with high sodalite. The glasses were then used to produce ceramic waste forms with a surrogate salt waste. The waste forms made using these new glasses were formulated to generate more sodalite than those made with previous baseline glasses for this type of waste. The coefficients of thermal expansion formore » the glass phase in the glass-bonded sodalite waste forms made with the new binder glasses were closer to the sodalite phase in the critical temperature region near and below the glass transition temperature than previous binder glasses used. Finally, these improvements should result in lower probability of cracking in the full-scale monolithic ceramic waste form, leading to better long-term chemical durability.« less

  20. Crack propagation and the material removal mechanism of glass-ceramics by the scratch test.

    PubMed

    Qiu, Zhongjun; Liu, Congcong; Wang, Haorong; Yang, Xue; Fang, Fengzhou; Tang, Junjie

    2016-12-01

    To eliminate the negative effects of surface flaws and subsurface damage of glass-ceramics on clinical effectiveness, crack propagation and the material removal mechanism of glass-ceramics were studied by single and double scratch experiments conducted using an ultra-precision machine. A self-manufactured pyramid shaped single-grit tool with a small tip radius was used as the scratch tool. The surface and subsurface crack propagations and interactions, surface morphology and material removal mechanism were investigated. The experimental results showed that the propagation of lateral cracks to the surface and the interaction between the lateral cracks and radial cracks are the two main types of material peeling, and the increase of the scratch depth increases the propagation angle of the radial cracks and the interaction between the cracks. In the case of a double scratch, the propagation of lateral cracks and radial cracks between paired scratches results in material peeling. The interaction between adjacent scratches depends on the scratch depth and separation distance. There is a critical separation distance where the normalized material removal volume reaches its peak. These findings can help reduce surface flaws and subsurface damage induced by the grinding process and improve the clinical effectiveness of glass-ceramics used as biological substitute and repair materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Distance stereotest using a 3-dimensional monitor for adult subjects.

    PubMed

    Kim, Jongshin; Yang, Hee Kyung; Kim, Youngmin; Lee, Byoungho; Hwang, Jeong-Min

    2011-06-01

    To evaluate the validity and test-retest reliability of a contour-based 3-dimensional (3-D) monitor distance stereotest (distance 3-D stereotest) and to measure the maximum horizontal disparity that can be fused with disparity vergence for determining the largest measurable disparity of true stereopsis. Observational case series. Sixty-four normal adult subjects (age range, 23 to 39 years) were recruited. Contour-based circles (crossed disparity, 5000 to 20 seconds of arc; Microsoft Visual Studio C(++) 6.0; Microsoft, Inc, Seattle, Washington, USA) were generated on a 3-D monitor (46-inch stereoscopic display) using polarization glasses and were presented to subjects with normal binocularity at 3 m. While the position of the stimulus changed among 4 possible locations, the subjects were instructed to press the corresponding position of the stimulus on a keypad. The results with the new distance 3-D stereotest were compared with those from the distance Randot stereotest. The results of the distance 3-D stereotest and the distance Randot stereotests were identical in 64% and within 1 disparity level in 97% of normal adults. Scores obtained with the 2 tests showed a statistically significant correlation (r = 0.324, P = .009). The half-width of the 95% limit of agreement was 0.47 log seconds of arc (1.55 octaves) using the distance 3-D stereotest--similar to or better than that obtained with conventional distance stereotests. The maximum binocular disparity that can be fused with vergence was 1828 ± 794 seconds of arc (range, 4000 to 500). The distance 3-D stereotest showed good concordance with the distance Randot stereotest and relatively good test-retest reliability, supporting the validity of the distance 3-D stereotest. The normative data set obtained from the present study can serve as a useful reference for quantitative assessment of a wide range of binocular sensory abnormalities. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Eco-efficient waste glass recycling: Integrated waste management and green product development through LCA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blengini, Gian Andrea, E-mail: blengini@polito.it; CNR-IGAG, Institute of Environmental Geology and Geo-Engineering, Corso Duca degli Abruzzi 24, 10129 Turin; Busto, Mirko, E-mail: mirko.busto@polito.it

    Highlights: Black-Right-Pointing-Pointer A new eco-efficient recycling route for post-consumer waste glass was implemented. Black-Right-Pointing-Pointer Integrated waste management and industrial production are crucial to green products. Black-Right-Pointing-Pointer Most of the waste glass rejects are sent back to the glass industry. Black-Right-Pointing-Pointer Recovered co-products give more environmental gains than does avoided landfill. Black-Right-Pointing-Pointer Energy intensive recycling must be limited to waste that cannot be closed-loop recycled. - Abstract: As part of the EU Life + NOVEDI project, a new eco-efficient recycling route has been implemented to maximise resources and energy recovery from post-consumer waste glass, through integrated waste management and industrial production.more » Life cycle assessment (LCA) has been used to identify engineering solutions to sustainability during the development of green building products. The new process and the related LCA are framed within a meaningful case of industrial symbiosis, where multiple waste streams are utilised in a multi-output industrial process. The input is a mix of rejected waste glass from conventional container glass recycling and waste special glass such as monitor glass, bulbs and glass fibres. The green building product is a recycled foam glass (RFG) to be used in high efficiency thermally insulating and lightweight concrete. The environmental gains have been contrasted against induced impacts and improvements have been proposed. Recovered co-products, such as glass fragments/powders, plastics and metals, correspond to environmental gains that are higher than those related to landfill avoidance, whereas the latter is cancelled due to increased transportation distances. In accordance to an eco-efficiency principle, it has been highlighted that recourse to highly energy intensive recycling should be limited to waste that cannot be closed-loop recycled.« less

  3. Inverted glass harp

    NASA Astrophysics Data System (ADS)

    Quinn, Daniel B.; Rosenberg, Brian J.

    2015-08-01

    We present an analytical treatment of the acoustics of liquid-filled wine glasses, or "glass harps." The solution is generalized such that under certain assumptions it reduces to previous glass harp models, but also leads to a proposed musical instrument, the "inverted glass harp," in which an empty glass is submerged in a liquid-filled basin. The versatility of the solution demonstrates that all glass harps are governed by a family of solutions to Laplace's equation around a vibrating disk. Tonal analyses of recordings for a sample glass are offered as confirmation of the scaling predictions.

  4. (Computer) Vision without Sight

    PubMed Central

    Manduchi, Roberto; Coughlan, James

    2012-01-01

    Computer vision holds great promise for helping persons with blindness or visual impairments (VI) to interpret and explore the visual world. To this end, it is worthwhile to assess the situation critically by understanding the actual needs of the VI population and which of these needs might be addressed by computer vision. This article reviews the types of assistive technology application areas that have already been developed for VI, and the possible roles that computer vision can play in facilitating these applications. We discuss how appropriate user interfaces are designed to translate the output of computer vision algorithms into information that the user can quickly and safely act upon, and how system-level characteristics affect the overall usability of an assistive technology. Finally, we conclude by highlighting a few novel and intriguing areas of application of computer vision to assistive technology. PMID:22815563

  5. Composition, production and procurement of glass at San Vincenzo Al Volturno: an early Medieval monastic complex in Southern Italy.

    PubMed

    Schibille, Nadine; Freestone, Ian C

    2013-01-01

    136 glasses from the ninth-century monastery of San Vincenzo and its workshops have been analysed by electron microprobe in order to situate the assemblage within the first millennium CE glass making tradition. The majority of the glass compositions can be paralleled by Roman glass from the first to third centuries, with very few samples consistent with later compositional groups. Colours for trailed decoration on vessels, for vessel bodies and for sheet glass for windows were largely produced by melting the glass tesserae from old Roman mosaics. Some weakly-coloured transparent glass was obtained by re-melting Roman window glass, while some was produced by melting and mixing of tesserae, excluding the strongly coloured cobalt blues. Our data suggest that to feed the needs of the glass workshop, the bulk of the glass was removed as tesserae and windows from a large Roman building. This is consistent with a historical account according to which the granite columns of the monastic church were spolia from a Roman temple in the region. The purported shortage of natron from Egypt does not appear to explain the dependency of San Vincenzo on old Roman glass. Rather, the absence of contemporary primary glass may reflect the downturn in long-distance trade in the later first millennium C.E., and the role of patronage in the "ritual economy" founded upon donations and gift-giving of the time.

  6. Pressure Induced Liquid-to-Liquid Transition in Zr-based Supercooled Melts and Pressure Quenched Glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dmowski, W.; Gierlotka, S.; Wang, Z.

    Through high-energy x-ray diffraction and atomic pair density function analysis we find that Zr-based metallic alloy, heated to the supercooled liquid state under hydrostatic pressure and then quenched to room temperature, exhibits a distinct glassy structure. The PDF indicates that the Zr-Zr distances in this glass are significantly reduced compared to those quenched without pressure. Annealing at the glass transition temperature at ambient pressure reverses structural changes and the initial glassy state is recovered. This result suggests that pressure causes a liquid-to-liquid phase transition in this metallic alloy supercooled melt. Such a pressure induced transition is known for covalent liquids,more » but has not been observed for metallic liquids. The High Pressure Quenched glasses are stable in ambient conditions after decompression.« less

  7. Oxynitride glass fibers

    NASA Technical Reports Server (NTRS)

    Patel, Parimal J.; Messier, Donald R.; Rich, R. E.

    1991-01-01

    Research at the Army Materials Technology Laboratory (AMTL) and elsewhere has shown that many glass properties including elastic modulus, hardness, and corrosion resistance are improved markedly by the substitution of nitrogen for oxygen in the glass structure. Oxynitride glasses, therefore, offer exciting opportunities for making high modulus, high strength fibers. Processes for making oxynitride glasses and fibers of glass compositions similar to commercial oxide glasses, but with considerable enhanced properties, are discussed. We have made glasses with elastic moduli as high as 140 GPa and fibers with moduli of 120 GPa and tensile strengths up to 2900 MPa. AMTL holds a U.S. patent on oxynitride glass fibers, and this presentation discusses a unique process for drawing small diameter oxynitride glass fibers at high drawing rates. Fibers are drawn through a nozzle from molten glass in a molybdenum crucible at 1550 C. The crucible is situated in a furnace chamber in flowing nitrogen, and the fiber is wound in air outside of the chamber, making the process straightforward and commercially feasible. Strengths were considerably improved by improving glass quality to minimize internal defects. Though the fiber strengths were comparable with oxide fibers, work is currently in progress to further improve the elastic modulus and strength of fibers. The high elastic modulus of oxynitride glasses indicate their potential for making fibers with tensile strengths surpassing any oxide glass fibers, and we hope to realize that potential in the near future.

  8. Beauty and cuteness in peripheral vision

    PubMed Central

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  9. Flight Test Comparison Between Enhanced Vision (FLIR) and Synthetic Vision Systems

    NASA Technical Reports Server (NTRS)

    Arthur, Jarvis J., III; Kramer, Lynda J.; Bailey, Randall E.

    2005-01-01

    Limited visibility and reduced situational awareness have been cited as predominant causal factors for both Controlled Flight Into Terrain (CFIT) and runway incursion accidents. NASA s Synthetic Vision Systems (SVS) project is developing practical application technologies with the goal of eliminating low visibility conditions as a causal factor to civil aircraft accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. A major thrust of the SVS project involves the development/demonstration of affordable, certifiable display configurations that provide intuitive out-the-window terrain and obstacle information with advanced pathway guidance. A flight test evaluation was conducted in the summer of 2004 by NASA Langley Research Center under NASA s Aviation Safety and Security, Synthetic Vision System - Commercial and Business program. A Gulfstream G-V aircraft, modified and operated under NASA contract by the Gulfstream Aerospace Corporation, was flown over a 3-week period at the Reno/Tahoe International Airport and an additional 3-week period at the NASA Wallops Flight Facility to evaluate integrated Synthetic Vision System concepts. Flight testing was conducted to evaluate the performance, usability, and acceptance of an integrated synthetic vision concept which included advanced Synthetic Vision display concepts for a transport aircraft flight deck, a Runway Incursion Prevention System, an Enhanced Vision Systems (EVS), and real-time Database Integrity Monitoring Equipment. This paper focuses on comparing qualitative and subjective results between EVS and SVS display concepts.

  10. Present Vision--Future Vision.

    ERIC Educational Resources Information Center

    Fitterman, L. Jeffrey

    This paper addresses issues of current and future technology use for and by individuals with visual impairments and blindness in Florida. Present technology applications used in vision programs in Florida are individually described, including video enlarging, speech output, large inkprint, braille print, paperless braille, and tactual output…

  11. Glass binder development for a glass-bonded sodalite ceramic waste form

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, Brian J.; Vienna, John D.; Frank, Steven M.

    This paper discusses work to develop Na2O-B2O3-SiO2 glass binders for immobilizing LiCl-KCl eutectic salt waste in a glass-bonded sodalite waste form following electrochemical reprocessing of used metallic nuclear fuel. Here, five new glasses with high Na2O contents were designed to generate waste forms having higher sodalite contents and fewer stress fractures. The structural, mechanical, and thermal properties of the new glasses were measured using variety of analytical techniques. The glasses were then used to produce ceramic waste forms with surrogate salt waste. The materials made using the glasses developed during this study were formulated to generate more sodalite than materialsmore » made with previous baseline glasses used. The coefficients of thermal expansion for the glass phase in the glass-bonded sodalite waste forms made with the new binder glasses were closer to the sodalite phase in the critical temperature region near and below the glass transition temperature. These improvements should result in lower probability of cracking in the full-scale monolithic ceramic waste form, leading to better long-term chemical durability. Additionally, a model generated during this study for predicting softening temperature of silicate binder glasses is presented.« less

  12. Efficacy of vision therapy in children with learning disability and associated binocular vision anomalies.

    PubMed

    Hussaindeen, Jameel Rizwana; Shah, Prerana; Ramani, Krishna Kumar; Ramanujan, Lalitha

    To report the frequency of binocular vision (BV) anomalies in children with specific learning disorders (SLD) and to assess the efficacy of vision therapy (VT) in children with a non-strabismic binocular vision anomaly (NSBVA). The study was carried out at a centre for learning disability (LD). Comprehensive eye examination and binocular vision assessment was carried out for 94 children (mean (SD) age: 15 (2.2) years) diagnosed with specific learning disorder. BV assessment was done for children with best corrected visual acuity of ≥6/9 - N6, cooperative for examination and free from any ocular pathology. For children with a diagnosis of NSBVA (n=46), 24 children were randomized to VT and no intervention was provided to the other 22 children who served as experimental controls. At the end of 10 sessions of vision therapy, BV assessment was performed for both the intervention and non-intervention groups. Binocular vision anomalies were found in 59 children (62.8%) among which 22% (n=13) had strabismic binocular vision anomalies (SBVA) and 78% (n=46) had a NSBVA. Accommodative infacility (AIF) was the commonest of the NSBVA and found in 67%, followed by convergence insufficiency (CI) in 25%. Post-vision therapy, the intervention group showed significant improvement in all the BV parameters (Wilcoxon signed rank test, p<0.05) except negative fusional vergence. Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  13. The use of films to simulate age-related declines in yellow vision.

    PubMed

    Yoshida, C A; Sakuraba, S

    1996-06-01

    One of characteristics of normal age-related vision losses depends on yellow-intensity in the lens of the eye. (1) We investigated discrimination between seven intensities of yellow in 303 elderly people aged from late 60s to early 90s. The results demonstrated that the failures of vision increase with age, and the losses depend on yellow intensity. (2) We got a yellow index (YI) from different Y-intensity color charts used in (I) above, covering 12 kinds of marketable yellow films, and selected two kinds of films which match (YI) original color charts, corresponding to 53% or 89% of Y intensity. (3) Finally, we judged that all of these colors' xy-chromaticities with or without the two films, were exactly on the unique-yellow line in the diagram, which means a pure yellow, not mixed. (4) Then, these two films could simulate each of the mid-level or high-level Y intensity, respectively, in age-related vision. (5) We analyzed changes of all kinds of colors (220) in xy-chromaticity diagrams and obtained mean changing distances from every original chromatogram compared to the others. These data would be useful for architects or designers to design cities or buildings for use by the elderly.

  14. Characterization and electrical properties of V 2O 5-CuO-P 2O 5 glasses

    NASA Astrophysics Data System (ADS)

    Al-Assiri, M. S.

    2008-08-01

    Characterization and electrical properties of vanadium-copper-phosphate glasses of compositions xV 2O 5-(40- x)CuO-60P 2O 5 have been reported. X-ray diffraction (XRD) confirms the amorphous nature of these glasses. It was observed that, the density ( d) decreases gradually while the molar volume ( Vm) increases with the increase of the vanadium oxide content in such glasses. This may be due to the effect of the polarizing power strength, PPS, which is a measure of ratio of the cation valance to its diameter. The dc conductivity increases while the activation energy decreases with the increase of the V 2O 5 content. The dc conductivity in the present glasses is electronic and depends strongly upon the average distance, R, between the vanadium ions. Analysis of the electrical properties has been made in the light of small polaron hopping model. The parameters obtained from the fits of the experimental data to this model are reasonable and consistent with glass composition. The conduction is attributed to non-adiabatic hopping of small polaron.

  15. Evolutionary analysis of vision genes identifies potential drivers of visual differences between giraffe and okapi

    PubMed Central

    Agaba, Morris; Cavener, Douglas R.

    2017-01-01

    giraffe and okapi vision adaptations. At least some of the genes that exhibit signature of selection may reflect adaptive response to differences in giraffe and okapi habitat. We hypothesize that requirement for long distance vision associated with predation and communication with conspecifics likely played an important role in the adaptive pressure on giraffe vision genes. PMID:28396824

  16. Evolutionary analysis of vision genes identifies potential drivers of visual differences between giraffe and okapi.

    PubMed

    Ishengoma, Edson; Agaba, Morris; Cavener, Douglas R

    2017-01-01

    least some of the genes that exhibit signature of selection may reflect adaptive response to differences in giraffe and okapi habitat. We hypothesize that requirement for long distance vision associated with predation and communication with conspecifics likely played an important role in the adaptive pressure on giraffe vision genes.

  17. Learning a Mahalanobis Distance-Based Dynamic Time Warping Measure for Multivariate Time Series Classification.

    PubMed

    Mei, Jiangyuan; Liu, Meizhu; Wang, Yuan-Fang; Gao, Huijun

    2016-06-01

    Multivariate time series (MTS) datasets broadly exist in numerous fields, including health care, multimedia, finance, and biometrics. How to classify MTS accurately has become a hot research topic since it is an important element in many computer vision and pattern recognition applications. In this paper, we propose a Mahalanobis distance-based dynamic time warping (DTW) measure for MTS classification. The Mahalanobis distance builds an accurate relationship between each variable and its corresponding category. It is utilized to calculate the local distance between vectors in MTS. Then we use DTW to align those MTS which are out of synchronization or with different lengths. After that, how to learn an accurate Mahalanobis distance function becomes another key problem. This paper establishes a LogDet divergence-based metric learning with triplet constraint model which can learn Mahalanobis matrix with high precision and robustness. Furthermore, the proposed method is applied on nine MTS datasets selected from the University of California, Irvine machine learning repository and Robert T. Olszewski's homepage, and the results demonstrate the improved performance of the proposed approach.

  18. Evidence for the need for vision screening of school children in Turkey.

    PubMed

    Azizoğlu, Serap; Crewther, Sheila G; Şerefhan, Funda; Barutchu, Ayla; Göker, Sinan; Junghans, Barbara M

    2017-12-02

    In many countries, access to general health and eye care is related to an individual's socioeconomic status (SES). We aimed to examine the prevalence of oculo-visual disorders in children in Istanbul Turkey, drawn from schools at SES extremes but geographically nearby. Three school-based vision screenings (presenting distance visual acuity, cover test, eye assessment history, colour vision, gross stereopsis and non-cycloplegic autorefraction) were conducted on 81% of a potential 1014 primary-school children aged 4-10 years from two private (high SES) schools and a nearby government (low SES) school in central Istanbul. Prevalence of refractive errors and school-based differences were analysed using parametric statistics (ANOVA). The remaining oculo-visual aspects were compared using non-parametric tests. Of the 823 children with mean age 6.7 ± 2.2 years, approximately 10% were referred for a full eye examination (8.2% and 16.3% of private/government schools respectively). Vision had not been previously examined in nearly 22% of private school children and 65% of government school children. Of all children, 94.5% were able to accurately identify the 6/9.5 [LogMAR 0.2] line of letters/shapes with each eye and 86.6% the 6/6 line [LogMAR 0], while 7.9% presented wearing spectacles, 3.8% had impaired colour vision, 1.5% had grossly impaired stereo-vision, 1.5% exhibited strabismus, 1.8% were suspected to have amblyopia and 0.5% had reduced acuity of likely organic origin. Of the 804 without strabismus, amblyopia or organic conditions, 6.0% were myopic ≤ - 0.50DS, 0.6% hyperopic ≥ + 2.00DS, 7.7% astigmatic ≥1.00 DC and 6.2% anisometropic ≥1.00DS. The results highlight the need for general vision screenings for all children prior to school entry given the varied and different pattern of visual problems associated with lifestyle differences in two populations raised in the same urban locale but drawn from different socioeconomic backgrounds.

  19. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cahoon, Erica M.; Almirall, Jose R.

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and themore » mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.« less

  20. Thermal, optical and structural properties of Dy3+ doped sodium aluminophosphate glasses

    NASA Astrophysics Data System (ADS)

    Kaur, Manpreet; Singh, Anupinder; Thakur, Vanita; Singh, Lakhwant

    2016-03-01

    Trivalent Dysprosium doped sodium aluminophosphate glasses with composition 50P2O5-10Al2O3-(20-x)Na2O-20CaO-xDy2O3 (x varying from 0 to 5 mol%) were prepared by melt quench technique. The density of the prepared samples was measured using Archimedes principle and various physical properties like molar volume, rare earth ion concentration, polaron radius, inter nuclear distance and field strength were calculated using different formulae. The differential scanning calorimetry (DSC) was carried out to study the thermal stability of prepared glasses. The UV Visible absorption spectra of the dysprosium doped glasses were found to be comprised of ten absorption bands which correspond to transitions from ground state 6H15/2 to various excited states. The indirect optical band gap energy of the samples was calculated by Tauc's plot and the optical energy was found to be attenuated with Dy3+ ions. The photoluminescence spectrum revealed that Dy3+ doped aluminophosphate glasses have strong emission bands in the visible region. A blue emission band centred at 486 nm, a bright yellow band centred at 575 nm and a weak red band centred at 668 nm were observed in the emission spectrum due to excitation at 352 nm wavelength. Both FTIR and Raman spectra assert slight structural changes induced in the host glass network with Dy3+ ions.

  1. Low Vision Aids in Glaucoma

    PubMed Central

    Khanna, Anjani

    2012-01-01

    A large number of glaucoma patients suffer from vision impairments that qualify as low vision. Additional difficulties associated with low vision include problems with glare, lighting, and contrast, which can make daily activities extremely challenging. This article elaborates on how low vision aids can help with various tasks that visually impaired glaucoma patients need to do each day, to take care of themselves and to lead an independent life. PMID:27990068

  2. Ocular injuries from exploding glass-bottled Coca-Cola® drinks in Port Harcourt, Nigeria

    PubMed Central

    Pedro-Egbe, Chinyere Nnenne; Ejimadu, Chibuike Sydney; Nwachukwu, Henrietta

    2011-01-01

    Background: Eye injuries and subsequent loss of vision from the glass and caps of exploding pressurized bottled drinks have been well reported, and as a result most developed countries now use mainly plastic bottles. In Nigeria, however, most drinks are still sold in glass bottles and ocular injuries from this source are therefore not uncommon. Aim: To retrospectively analyze ocular injuries resulting from exploding glass-bottled Coca-Cola® and propose ways of eliminating such injuries in future. Setting: Eye Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. Materials and methods: The medical records of all cases of ocular injury that presented at the Eye Clinic of the University of Port Harcourt Teaching Hospital over a 5-year period (January 2006 to December 2010) were retrieved and relevant data including age, sex, occupation, events surrounding bottle explosion, and type of ocular injury sustained were extracted. Results: A total of 426 cases of ocular injuries was seen during the period under review. There were 335 (78.6%) males and 91 (21.4%) females. Six patients had ocular injury from exploding glass-bottled Coca-Cola®, giving an incidence of 1.4%. The presenting visual acuities (VA) were light perception (2 cases), counting fingers (2 cases), and 1 VA of 6/24 and 1 VA of 6/12. There were 4 (66.7%) cases of corneoscleral laceration with uveal prolapse and 1 case of total hyphema. Conclusion: Because pressurized glass-bottles can explode with normal handling, legislation to ban the use of glass containers for bottling carbonated drinks will go a long way to reducing ocular morbidity from this source. Plastic bottles should be introduced as an alternative. PMID:21629570

  3. Computer vision syndrome: a review of ocular causes and potential treatments.

    PubMed

    Rosenfield, Mark

    2011-09-01

    Computer vision syndrome (CVS) is the combination of eye and vision problems associated with the use of computers. In modern western society the use of computers for both vocational and avocational activities is almost universal. However, CVS may have a significant impact not only on visual comfort but also occupational productivity since between 64% and 90% of computer users experience visual symptoms which may include eyestrain, headaches, ocular discomfort, dry eye, diplopia and blurred vision either at near or when looking into the distance after prolonged computer use. This paper reviews the principal ocular causes for this condition, namely oculomotor anomalies and dry eye. Accommodation and vergence responses to electronic screens appear to be similar to those found when viewing printed materials, whereas the prevalence of dry eye symptoms is greater during computer operation. The latter is probably due to a decrease in blink rate and blink amplitude, as well as increased corneal exposure resulting from the monitor frequently being positioned in primary gaze. However, the efficacy of proposed treatments to reduce symptoms of CVS is unproven. A better understanding of the physiology underlying CVS is critical to allow more accurate diagnosis and treatment. This will enable practitioners to optimize visual comfort and efficiency during computer operation. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.

  4. Vision and Driving

    PubMed Central

    Owsley, Cynthia; McGwin, Gerald

    2010-01-01

    Driving is the primary means of personal travel in many countries and is relies heavily on vision for its successful execution. Research over the past few decades has addressed the role of vision in driver safety (motor vehicle collision involvement) and in driver performance (both on-road and using interactive simulators in the laboratory). Here we critically review what is currently known about the role of various aspects of visual function in driving. We also discuss translational research issues on vision screening for licensure and re-licensure and rehabilitation of visually impaired persons who want to drive. PMID:20580907

  5. Comparison of a model vapor deposited glass films to equilibrium glass films

    NASA Astrophysics Data System (ADS)

    Flenner, Elijah; Berthier, Ludovic; Charbonneau, Patrick; Zamponi, Francesco

    Vapor deposition of particles onto a substrate held at around 85% of the glass transition temperature can create glasses with increased density, enthalpy, kinetic stability, and mechanical stability compared to an ordinary glass created by cooling. It is estimated that an ordinary glass would need to age thousands of years to reach the kinetic stability of a vapor deposited glass, and a natural question is how close to the equilibrium is the vapor deposited glass. To understand the process, algorithms akin to vapor deposition are used to create simulated glasses that have a higher kinetic stability than their annealed counterpart, although these glasses may not be well equilibrated either. Here we use novel models optimized for a swap Monte Carlo algorithm in order to create equilibrium glass films and compare their properties with those of glasses obtained from vapor deposition algorithms. This approach allows us to directly assess the non-equilibrium nature of vapor-deposited ultrastable glasses. Simons Collaboration on Cracking the Glass Problem and NSF Grant No. DMR 1608086.

  6. Impact of cataract surgery on vision-related life performances: the usefulness of Real-Life Vision Test for cataract surgery outcomes evaluation

    PubMed Central

    Ni, W; Li, X; Hou, Z; Zhang, H; Qiu, W; Wang, W

    2015-01-01

    Purpose Real-Life Vision Test (RLVT) is a newly developed performance-based measures of functional vision. This present study is designed to determine whether it could be a meaningful assessment for cataract surgery outcomes evaluation. Patients and methods Age-related cataract patients (56) who scheduled for bilateral cataract surgery and 44 age-matched controls were evaluated by four types of measurements: (1) demographic, medical, cognitive and depressive evaluation, and the reaction time testing; (2) clinical measures (visual acuity, contrast sensitivity, stereopsis, and color perception); (3) the 25-item National Eye Institute's Visual Functioning Questionnaire (NEI-VFQ); (4) the RLVT. Spearman's coefficients and multiple regression analysis were conducted to investigate the relationship among RLVT, clinical measures, and self-report assessment of visual function. Results The results of RLVT, clinical measures, and NEI-VFQ total scores were improved significantly after cataract surgery. There were no differences between control subjects and post-surgery patients with respect to NEI-VFQ-25 total scores, self-rating depression scale scores and three tasks of RLVT. Change of RLVT was significantly associated with the change of clinical measures in the cataract group. Multiple regression analysis demonstrated that change of distance, intermediate, and near visual acuity, and binocular contrast sensitivity were significant predictors of improvements of RLVT. Conclusions Cataract surgery could improve real-world visual ability effectively for cataract patients. Our study highlights the potential usefulness of RLVT as an adjunct to the current outcomes evaluation system for cataract surgery. The use of RLVT combined with clinical and self-survey methods may be the comprehensive strategy to manifest the impact of cataract surgery on patients' overall vision-related quality of life. PMID:26272444

  7. Absorption Spectroscopy Analysis of Calcium-Phosphate Glasses Highly Doped with Monovalent Copper.

    PubMed

    Jiménez, José A

    2016-06-03

    CaO-P2 O5 glasses with high concentrations of monovalent copper ions were prepared by a simple melt-quench method through CuO and SnO co-doping. Spectroscopic characterization was carried out by optical absorption with the aim of analyzing the effects of Cu(+) ions on the optical band-gap energies, which were estimated on the basis of indirect-allowed transitions. The copper(I) content is estimated in the CuO/SnO-containing glasses after the assessment of the concentration dependence of Cu(2+) absorption in the visible region for CuO singly doped glasses. An exponential dependence of the change in optical band gaps (relative to the host) with Cu(+) concentration is inferred up to about 10 mol %. However, the entire range is divided into two distinct linear regions that are characterized by different rates of change with respect to concentration: 1) below 5 mol %, where the linear dependence presents a relatively high magnitude of the slope; and 2) from 5-10 mol %, where a lower magnitude of the slope is manifested. With increasing concentration, the mean Cu(+) -Cu(+) interionic distance decreases, thereby decreasing the sensitivity of monovalent copper for light absorption. The decrease in optical band-gap energies is ultimately shown to follow a linear dependence with the interionic distance, suggesting the potential of the approach to gauge the concentration of monovalent copper straightforwardly in amorphous hosts. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Vision Voice: A Multimedia Exploration of Diabetes and Vision Loss in East Harlem.

    PubMed

    Ives, Brett; Nedelman, Michael; Redwood, Charysse; Ramos, Michelle A; Hughson-Andrade, Jessica; Hernandez, Evelyn; Jordan, Dioris; Horowitz, Carol R

    2015-01-01

    East Harlem, New York, is a community actively struggling with diabetes and its complications, including vision-related conditions that can affect many aspects of daily life. Vision Voice was a qualitative community-based participatory research (CBPR) study that intended to better understand the needs and experiences of people living with diabetes, other comorbid chronic illnesses, and vision loss in East Harlem. Using photovoice methodology, four participants took photographs, convened to review their photographs, and determined overarching themes for the group's collective body of work. Identified themes included effect of decreased vision function on personal independence/mobility and self-management of chronic conditions and the importance of informing community members and health care providers about these issues. The team next created a documentary film that further develops the narratives of the photovoice participants. The Vision Voice photovoice project was an effective tool to assess community needs, educate and raise awareness.

  9. Evidence for enhanced discrimination of virtual auditory distance among blind listeners using level and direct-to-reverberant cues.

    PubMed

    Kolarik, Andrew J; Cirstea, Silvia; Pardhan, Shahina

    2013-02-01

    Totally blind listeners often demonstrate better than normal capabilities when performing spatial hearing tasks. Accurate representation of three-dimensional auditory space requires the processing of available distance information between the listener and the sound source; however, auditory distance cues vary greatly depending upon the acoustic properties of the environment, and it is not known which distance cues are important to totally blind listeners. Our data show that totally blind listeners display better performance compared to sighted age-matched controls for distance discrimination tasks in anechoic and reverberant virtual rooms simulated using a room-image procedure. Totally blind listeners use two major auditory distance cues to stationary sound sources, level and direct-to-reverberant ratio, more effectively than sighted controls for many of the virtual distances tested. These results show that significant compensation among totally blind listeners for virtual auditory spatial distance leads to benefits across a range of simulated acoustic environments. No significant differences in performance were observed between listeners with partial non-correctable visual losses and sighted controls, suggesting that sensory compensation for virtual distance does not occur for listeners with partial vision loss.

  10. Learning from vision-to-touch is different than learning from touch-to-vision.

    PubMed

    Wismeijer, Dagmar A; Gegenfurtner, Karl R; Drewing, Knut

    2012-01-01

    We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two "natural" tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two "novel" tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision.

  11. Learning from vision-to-touch is different than learning from touch-to-vision

    PubMed Central

    Wismeijer, Dagmar A.; Gegenfurtner, Karl R.; Drewing, Knut

    2012-01-01

    We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two “natural” tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two “novel” tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision. PMID:23181012

  12. Diopside-Fluorapatite-Wollastonite Based Bioactive Glasses and Glass-ceramics =

    NASA Astrophysics Data System (ADS)

    Kansal, Ishu

    Bioactive glasses and glass-ceramics are a class of biomaterials which elicit special response on their surface when in contact with biological fluids, leading to strong bonding to living tissue. This particular trait along with good sintering ability and high mechanical strength make them ideal materials for scaffold fabrication. The work presented in this thesis is directed towards understanding the composition-structure-property relationships in potentially bioactive glasses designed in CaO-MgO-P2O5-SiO2-F system, in some cases with added Na2O. The main emphasis has been on unearthing the influence of glass composition on molecular structure, sintering ability and bioactivity of phosphosilicate glasses. The parent glass compositions have been designed in the primary crystallization field of the pseudo-ternary system of diopside (CaO•MgO•2SiO2) - fluorapatite (9CaO•3P2O5•CaF2) - wollastonite (CaO•SiO2), followed by studying the impact of compositional variations on the structure-property relationships and sintering ability of these glasses. All the glasses investigated in this work have been synthesized via melt-quenching route and have been characterized for their molecular structure, sintering ability, chemical degradation and bioactivity using wide array of experimental tools and techniques. It has been shown that in all investigated glass compositions the silicate network was mainly dominated by Q2 units while phosphate in all the glasses was found to be coordinated in orthophosphate environment. The glass compositions designed in alkali-free region of diopside - fluorapatite system demonstrated excellent sintering ability and good bioactivity in order to qualify them as potential materials for scaffold fabrication while alkali-rich bioactive glasses not only hinder the densification during sintering but also induce cytotoxicity in vitro, thus, are not ideal candidates for in vitro tissue engineering. One of our bioglass compositions with low sodium

  13. Panoramic stereo sphere vision

    NASA Astrophysics Data System (ADS)

    Feng, Weijia; Zhang, Baofeng; Röning, Juha; Zong, Xiaoning; Yi, Tian

    2013-01-01

    Conventional stereo vision systems have a small field of view (FOV) which limits their usefulness for certain applications. While panorama vision is able to "see" in all directions of the observation space, scene depth information is missed because of the mapping from 3D reference coordinates to 2D panoramic image. In this paper, we present an innovative vision system which builds by a special combined fish-eye lenses module, and is capable of producing 3D coordinate information from the whole global observation space and acquiring no blind area 360°×360° panoramic image simultaneously just using single vision equipment with one time static shooting. It is called Panoramic Stereo Sphere Vision (PSSV). We proposed the geometric model, mathematic model and parameters calibration method in this paper. Specifically, video surveillance, robotic autonomous navigation, virtual reality, driving assistance, multiple maneuvering target tracking, automatic mapping of environments and attitude estimation are some of the applications which will benefit from PSSV.

  14. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    DTIC Science & Technology

    2017-05-15

    repeatability to support correlation analysis. The AVT research grade tests also support interservice, international, industry, and academic partnerships...software, provides information concerning various menu options and operation of the test, and provides a brief description of each of the automated vision...2802, 6 Jun 2017. TABLE OF CONTENTS (concluded) Section Page 7.0 OBVA VISION TEST DESCRIPTIONS

  15. Yb3+-Er3+-Tm3+ co-doped nano-glass-ceramics tuneable up-conversion phosphor

    NASA Astrophysics Data System (ADS)

    Méndez-Ramos, J.; Rodriguez, V. D.; Tikhomirov, V. K.; Del-Castillo, J.; Yanes, A. C.

    2008-08-01

    Transparent Yb3+-Er3+-Tm3+ co-doped nano-glass-ceramics have been prepared, 32(SiO{2}) 9(AlO{1.5}) 31.5(CdF{2}) 18.5(PbF{2}) 5.5(ZnF{2}): 3.5(Yb-Er-TmF{3}) mol%, where the co-dopants partition mostly to the fluoride PbF{2}-based nano-crystals. A comparative study of the up-conversion luminescence in nano-glass-ceramics and its precursor glass indicates that these materials can be used as blue/green/red tuneable up-conversion phosphor, in particular for white light generation. A ratio between blue, green and red emission bands of the Tm3+ and Er3+ can be widely varied with nano-ceramming of the precursor glass and with changing a pump power of luminescence. The change in the ratio between the blue, green and red emission bands is explained to be due to substantial lowering phonon energy and shortening of inter-dopant distances with nano-ceramming of the precursor glass and due to change in the ratio of 2- and 3-photon up-conversion processes with pump power.

  16. FPGA Vision Data Architecture

    NASA Technical Reports Server (NTRS)

    Morfopoulos, Arin C.; Pham, Thang D.

    2013-01-01

    JPL has produced a series of FPGA (field programmable gate array) vision algorithms that were written with custom interfaces to get data in and out of each vision module. Each module has unique requirements on the data interface, and further vision modules are continually being developed, each with their own custom interfaces. Each memory module had also been designed for direct access to memory or to another memory module.

  17. FLORA™: Phase I development of a functional vision assessment for prosthetic vision users.

    PubMed

    Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy

    2015-07-01

    Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population to evaluate the impact of new vision-restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional visual ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional visual tasks for observation of performance and a case narrative summary. Results were analysed to determine whether the interview questions and functional visual tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, 26 subjects were assessed with the FLORA. Seven different evaluators administered the assessment. All 14 interview questions were asked. All 35 tasks for functional vision were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options—impossible (33 per cent), difficult (23 per cent), moderate (24 per cent) and easy (19 per cent)—were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with 'vision only' occurring 75 per cent on average with the System ON, and 29 per cent with the System OFF. The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as an assessment tool for functional vision and well-being. © 2015 The Authors. Clinical

  18. Characterization and in vitro bioactivity of zinc-containing bioactive glass and glass-ceramics.

    PubMed

    Du, Rui Lin; Chang, Jiang; Ni, Si Yu; Zhai, Wan Yin; Wang, Jun Ying

    2006-04-01

    Zinc-containing glass is prepared by the substitution of CaO in 58S bioactive glass with 0.5 and 4 wt% ZnO, and glass-ceramics are obtained by heat-treating the glass at 1,200 C. The bending strength and in vitro bioactivity of the glass and glass-ceramics are evaluated. The results indicate that Zn promotes the crystallization of SiO(2) and wollastonite in glass-ceramics, and proper crystallization can enhance the bending strength of the glass-ceramic. The in vitro results show that ZnO in glass retards the hydroxyapatite (HA) nucleation at the initial stage of simulated body fluid (SBF) soaking, but does not affect the growth of HA after long periods of soaking, and the ionic products of 58S4Z glass can stimulate the proliferation of osteoblast at certain concentrations. Osteoblasts attach well on both glass samples and glass-ceramic samples, but the high Si ion concentration released from glass samples restrains the proliferation of osteoblasts after 3 days of culture. In contrast, osteoblasts show good proliferation on glass-ceramic samples, and ZnO in glass-ceramics promotes the proliferation rate. The results in this study suggest that the glass and glass-ceramics with different ZnO content might be used as bioactive bone implant materials in different applications.

  19. Ibn al-Haitham--father of optics and describer of vision theory.

    PubMed

    Masic, Izet

    2008-01-01

    Among famous Arabic doctor belongs also Ibn Al-Haitam (known in the west as Alhazen) which is considered to be the greatest Muslim doctor and one of the greatest researches of optics for all times. Al Haitam is born in city Basra and immigrated to Egypt during reign of Caliph Al Hakim. He is quoted as excellent astronomer, mathematician and doctor as well as one of the best commentators of the Galen and Aristotle's work. He is the first medical scholar who teaches that light "does not originates from the eye but on opposite enters the eye", and in that manner corrects the wrong opinion of the Greeks about the nature of vision. According to this scholar retina is the center of vision and the impressions that it receives are transferred to the brain by the optical nerve, in order that brain afterwards create visual image in the symmetrical relationship for both retinas. Al-Haitam was the most important researcher of optics in Islam. He was convinced that the adequate theory of vision must combine Euclid and Ptolemy "mathematical" approach and "physical doctrine of the naturalists. The result of his reflections in the paper "Optics", supported by the experimental approach, is the new theory of vision, much richer and perfected than any before. He thought that light and color, two physical features that exist independently from the observed subject, in strait lines originates from the each point of visible object. Al Haitam concludes that what we perceive is actually the object which is on a certain distance from the eye and which have certain shape and size, and vision itself is the result of intervention by the visual material received by the brain and stored information's from previous experiences. Reception hypothesis (intromission) Al-Haitam exposed to mathematical testing, and then incorporated into already developed perception theory, which is still not completely explored by historians. In his experiments he used "dark chambers", trying to confirm the features

  20. How lateral inhibition and fast retinogeniculo-cortical oscillations create vision: A new hypothesis.

    PubMed

    Jerath, Ravinder; Cearley, Shannon M; Barnes, Vernon A; Nixon-Shapiro, Elizabeth

    2016-11-01

    The role of the physiological processes involved in human vision escapes clarification in current literature. Many unanswered questions about vision include: 1) whether there is more to lateral inhibition than previously proposed, 2) the role of the discs in rods and cones, 3) how inverted images on the retina are converted to erect images for visual perception, 4) what portion of the image formed on the retina is actually processed in the brain, 5) the reason we have an after-image with antagonistic colors, and 6) how we remember space. This theoretical article attempts to clarify some of the physiological processes involved with human vision. The global integration of visual information is conceptual; therefore, we include illustrations to present our theory. Universally, the eyeball is 2.4cm and works together with membrane potential, correspondingly representing the retinal layers, photoreceptors, and cortex. Images formed within the photoreceptors must first be converted into chemical signals on the photoreceptors' individual discs and the signals at each disc are transduced from light photons into electrical signals. We contend that the discs code the electrical signals into accurate distances and are shown in our figures. The pre-existing oscillations among the various cortices including the striate and parietal cortex, and the retina work in unison to create an infrastructure of visual space that functionally "places" the objects within this "neural" space. The horizontal layers integrate all discs accurately to create a retina that is pre-coded for distance. Our theory suggests image inversion never takes place on the retina, but rather images fall onto the retina as compressed and coiled, then amplified through lateral inhibition through intensification and amplification on the OFF-center cones. The intensified and amplified images are decompressed and expanded in the brain, which become the images we perceive as external vision. This is a theoretical

  1. Developing Administrative Vision.

    ERIC Educational Resources Information Center

    Chance, Edward W.

    Visionary leadership has emerged as a significant characteristic of high performing school administrators. Vision provides a sense of direction for the school and facilitates accomplishment. Administrators must move from authoritarian and managerial modes of operation to proactive leadership, and maintain a focus on the vision through turmoil and…

  2. The use of holographic and diffractive optics for optimized machine vision illumination for critical dimension inspection

    NASA Astrophysics Data System (ADS)

    Lizotte, Todd E.; Ohar, Orest

    2004-02-01

    Illuminators used in machine vision applications typically produce non-uniform illumination onto the targeted surface being observed, causing a variety of problems with machine vision alignment or measurement. In most circumstances the light source is broad spectrum, leading to further problems with image quality when viewed through a CCD camera. Configured with a simple light bulb and a mirrored reflector and/or frosted glass plates, these general illuminators are appropriate for only macro applications. Over the last 5 years newer illuminators have hit the market including circular or rectangular arrays of high intensity light emitting diodes. These diode arrays are used to create monochromatic flood illumination of a surface that is to be inspected. The problem with these illumination techniques is that most of the light does not illuminate the desired areas, but broadly spreads across the surface, or when integrated with diffuser elements, tend to create similar shadowing effects to the broad spectrum light sources. In many cases a user will try to increase the performance of these illuminators by adding several of these assemblies together, increasing the intensity or by moving the illumination source closer or farther from the surface being inspected. In this case these non-uniform techniques can lead to machine vision errors, where the computer machine vision may read false information, such as interpreting non-uniform lighting or shadowing effects as defects. This paper will cover a technique involving the use of holographic / diffractive hybrid optical elements that are integrated into standard and customized light sources used in the machine vision industry. The bulk of the paper will describe the function and fabrication of the holographic/diffractive optics and how they can be tailored to improve illuminator design. Further information will be provided a specific design and examples of it in operation will be disclosed.

  3. Regional variation in energy storage strategies in American glass eels from Eastern Canada.

    PubMed

    Gaillard, Mélanie; Bernatchez, Louis; Tremblay, Réjean; Audet, Céline

    2015-10-01

    Energy status was analyzed in glass eels captured during two early waves of arrival at the mouths of the Mersey River, Nova Scotia, Canada (MR), and Grande-Rivière-Blanche, Québec, Canada (GRB), and according to their salinity preference (freshwater, brackish, or saltwater). Glass eels captured in the GRB estuary were larger, more pigmented, and exhibited higher whole-body glycogen, phospholipid, and sterol and wax ester contents. Those from MR had a higher condition index and a higher whole-body triacylglycerol content, suggesting different patterns of storage and/or use of energy reserves. Within a river, a delay of two weeks in estuarine arrival was characterized by significantly lower energy reserves. No differences in energy storage were observed according to salinity preference. Thus, the results revealed the occurrence of different energy storage strategies according to glass eel migration distance and duration, but not according to salinity preference. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Method of recognizing the high-speed railway noise barriers based on the distance image

    NASA Astrophysics Data System (ADS)

    Ma, Le; Shao, Shuangyun; Feng, Qibo; Liu, Bingqian; Kim, Chol Ryong

    2016-10-01

    The damage or lack of the noise barriers is one of the important hidden troubles endangering the safety of high-speed railway. In order to obtain the vibration information of the noise barriers, the online detection systems based on laser vision were proposed. The systems capture images of the laser stripe on the noise barriers and export data files containing distance information between the detection systems on the train and the noise barriers. The vibration status or damage of the noise barriers can be estimated depending on the distance information. In this paper, we focused on the method of separating the area of noise barrier from the background automatically. The test results showed that the proposed method is in good efficiency and accuracy.

  5. Microscopic vision modeling method by direct mapping analysis for micro-gripping system with stereo light microscope.

    PubMed

    Wang, Yuezong; Zhao, Zhizhong; Wang, Junshuai

    2016-04-01

    We present a novel and high-precision microscopic vision modeling method, which can be used for 3D data reconstruction in micro-gripping system with stereo light microscope. This method consists of four parts: image distortion correction, disparity distortion correction, initial vision model and residual compensation model. First, the method of image distortion correction is proposed. Image data required by image distortion correction comes from stereo images of calibration sample. The geometric features of image distortions can be predicted though the shape deformation of lines constructed by grid points in stereo images. Linear and polynomial fitting methods are applied to correct image distortions. Second, shape deformation features of disparity distribution are discussed. The method of disparity distortion correction is proposed. Polynomial fitting method is applied to correct disparity distortion. Third, a microscopic vision model is derived, which consists of two models, i.e., initial vision model and residual compensation model. We derive initial vision model by the analysis of direct mapping relationship between object and image points. Residual compensation model is derived based on the residual analysis of initial vision model. The results show that with maximum reconstruction distance of 4.1mm in X direction, 2.9mm in Y direction and 2.25mm in Z direction, our model achieves a precision of 0.01mm in X and Y directions and 0.015mm in Z direction. Comparison of our model with traditional pinhole camera model shows that two kinds of models have a similar reconstruction precision of X coordinates. However, traditional pinhole camera model has a lower precision of Y and Z coordinates than our model. The method proposed in this paper is very helpful for the micro-gripping system based on SLM microscopic vision. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Correlation between physical properties and ultrasonic relaxation parameters in transition metal tellurite glasses

    NASA Astrophysics Data System (ADS)

    Abd El-Moneim, A.

    2003-07-01

    The correlation between activation energy of ultrasonic relaxation process through the temperature range from 140 to 300 K and some physical properties has been investigated in pure TeO 2 and transition metal TeO 2-V 2O 5 and TeO 2-MoO 3 glasses according to Bridge and Patel's theory. The oxygen density (loss centers), number of two-well systems, hopping distance and mechanical relaxation time have been calculated in these glasses from the data of density, bulk modulus and stretching force constant of the glass. It has been found that the acoustic activation energy increased linearly with both the oxygen density and the number of two-well systems. The correlation between the acoustic activation energy and bulk modulus was achieved through the stretching force constant of the network and other structural parameters. Moreover, the experimental values of activation energy (V) agree well with those calculated from an empirical equation presented in this study in the form V=2.9×10 -7 F( F/ K) 3.37, where F is the stretching force constant of the glass and K is the experimental bulk modulus.

  7. Application of vision measurements for modal analysis of wires for the purpose of overhead transmission lines monitoring

    NASA Astrophysics Data System (ADS)

    Mendrok, Krzysztof; Dworakowski, Ziemowit; Holak, Krzysztof; Kohut, Piotr

    2017-05-01

    Overhead transmission power lines are still one of the crucial elements of electro-energetic system. There are obvious advantages of using overhead transmission in the distribution of electricity. The amount of energy transported through a power line is determined by the distance between the wire and the ground or other objects placed beneath it (eg. trees). This distance is not fixed and depends on the overhang of the wire. This, in turn, is determined by many factors such as ambient temperature, humidity, precipitation, the value of current flowing through the wire. In order to optimize the wires electrical load, the monitoring of that overhang is required. One way to measure it is the non-contact measurement by vision system. It has the advantage, that using high-speed cameras respectively it also allows for vibration measurement and analysis of dynamic performance. That is very important while the wires are susceptible to the influence of wind, and the resulting vibrations interfere with the correct measurement of the overhang. The paper presents the results of vision measurements of the system vibrations and modal analysis carried out on their basis. The study was conducted on a specially made laboratory stand.

  8. A new color vision test to differentiate congenital and acquired color vision defects.

    PubMed

    Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak

    2007-07-01

    To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency. Observational cross-sectional study. Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004. To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. Error scores and ratio in quadrant analysis of the Seohan computerized hue test. The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval). The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.

  9. Why Vision 2020?

    ERIC Educational Resources Information Center

    Hinckley, June

    2000-01-01

    Discusses changes in technology, information, and people and the impact on music programs. The Vision 2020 project focuses on the future of music education. Addresses the events that created Vision 2020. Includes "The Housewright Declaration," a summarization of agreements from the Housewright Symposium on the Future of Music Education. (CMK)

  10. Dynamic Vision for Control

    DTIC Science & Technology

    2006-07-27

    unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT The goal of this project was to develop analytical and computational tools to make vision a Viable sensor for...vision.ucla. edu July 27, 2006 Abstract The goal of this project was to develop analytical and computational tools to make vision a viable sensor for the ... sensors . We have proposed the framework of stereoscopic segmentation where multiple images of the same obejcts were jointly processed to extract geometry

  11. Stereo Vision Inside Tire

    DTIC Science & Technology

    2015-08-21

    using the Open Computer Vision ( OpenCV ) libraries [6] for computer vision and the Qt library [7] for the user interface. The software has the...depth. The software application calibrates the cameras using the plane based calibration model from the OpenCV calib3D module and allows the...6] OpenCV . 2015. OpenCV Open Source Computer Vision. [Online]. Available at: opencv.org [Accessed]: 09/01/2015. [7] Qt. 2015. Qt Project home

  12. Composition, Production and Procurement of Glass at San Vincenzo al Volturno: An Early Medieval Monastic Complex in Southern Italy

    PubMed Central

    Schibille, Nadine; Freestone, Ian C.

    2013-01-01

    136 glasses from the ninth-century monastery of San Vincenzo and its workshops have been analysed by electron microprobe in order to situate the assemblage within the first millennium CE glass making tradition. The majority of the glass compositions can be paralleled by Roman glass from the first to third centuries, with very few samples consistent with later compositional groups. Colours for trailed decoration on vessels, for vessel bodies and for sheet glass for windows were largely produced by melting the glass tesserae from old Roman mosaics. Some weakly-coloured transparent glass was obtained by re-melting Roman window glass, while some was produced by melting and mixing of tesserae, excluding the strongly coloured cobalt blues. Our data suggest that to feed the needs of the glass workshop, the bulk of the glass was removed as tesserae and windows from a large Roman building. This is consistent with a historical account according to which the granite columns of the monastic church were spolia from a Roman temple in the region. The purported shortage of natron from Egypt does not appear to explain the dependency of San Vincenzo on old Roman glass. Rather, the absence of contemporary primary glass may reflect the downturn in long-distance trade in the later first millennium C.E., and the role of patronage in the “ritual economy” founded upon donations and gift-giving of the time. PMID:24146876

  13. Heating-induced glass-glass and glass-liquid transformations in computer simulations of water.

    PubMed

    Chiu, Janet; Starr, Francis W; Giovambattista, Nicolas

    2014-03-21

    Water exists in at least two families of glassy states, broadly categorized as the low-density (LDA) and high-density amorphous ice (HDA). Remarkably, LDA and HDA can be reversibly interconverted via appropriate thermodynamic paths, such as isothermal compression and isobaric heating, exhibiting first-order-like phase transitions. We perform out-of-equilibrium molecular dynamics simulations of glassy water using the ST2 model to study the evolution of LDA and HDA upon isobaric heating. Depending on pressure, glass-to-glass, glass-to-crystal, glass-to-vapor, as well as glass-to-liquid transformations are found. Specifically, heating LDA results in the following transformations, with increasing heating pressures: (i) LDA-to-vapor (sublimation), (ii) LDA-to-liquid (glass transition), (iii) LDA-to-HDA-to-liquid, (iv) LDA-to-HDA-to-liquid-to-crystal, and (v) LDA-to-HDA-to-crystal. Similarly, heating HDA results in the following transformations, with decreasing heating pressures: (a) HDA-to-crystal, (b) HDA-to-liquid-to-crystal, (c) HDA-to-liquid (glass transition), (d) HDA-to-LDA-to-liquid, and (e) HDA-to-LDA-to-vapor. A more complex sequence may be possible using lower heating rates. For each of these transformations, we determine the corresponding transformation temperature as function of pressure, and provide a P-T "phase diagram" for glassy water based on isobaric heating. Our results for isobaric heating dovetail with the LDA-HDA transformations reported for ST2 glassy water based on isothermal compression/decompression processes [Chiu et al., J. Chem. Phys. 139, 184504 (2013)]. The resulting phase diagram is consistent with the liquid-liquid phase transition hypothesis. At the same time, the glass phase diagram is sensitive to sample preparation, such as heating or compression rates. Interestingly, at least for the rates explored, our results suggest that the LDA-to-liquid (HDA-to-liquid) and LDA-to-HDA (HDA-to-LDA) transformation lines on heating are related

  14. Heating-induced glass-glass and glass-liquid transformations in computer simulations of water

    NASA Astrophysics Data System (ADS)

    Chiu, Janet; Starr, Francis W.; Giovambattista, Nicolas

    2014-03-01

    Water exists in at least two families of glassy states, broadly categorized as the low-density (LDA) and high-density amorphous ice (HDA). Remarkably, LDA and HDA can be reversibly interconverted via appropriate thermodynamic paths, such as isothermal compression and isobaric heating, exhibiting first-order-like phase transitions. We perform out-of-equilibrium molecular dynamics simulations of glassy water using the ST2 model to study the evolution of LDA and HDA upon isobaric heating. Depending on pressure, glass-to-glass, glass-to-crystal, glass-to-vapor, as well as glass-to-liquid transformations are found. Specifically, heating LDA results in the following transformations, with increasing heating pressures: (i) LDA-to-vapor (sublimation), (ii) LDA-to-liquid (glass transition), (iii) LDA-to-HDA-to-liquid, (iv) LDA-to-HDA-to-liquid-to-crystal, and (v) LDA-to-HDA-to-crystal. Similarly, heating HDA results in the following transformations, with decreasing heating pressures: (a) HDA-to-crystal, (b) HDA-to-liquid-to-crystal, (c) HDA-to-liquid (glass transition), (d) HDA-to-LDA-to-liquid, and (e) HDA-to-LDA-to-vapor. A more complex sequence may be possible using lower heating rates. For each of these transformations, we determine the corresponding transformation temperature as function of pressure, and provide a P-T "phase diagram" for glassy water based on isobaric heating. Our results for isobaric heating dovetail with the LDA-HDA transformations reported for ST2 glassy water based on isothermal compression/decompression processes [Chiu et al., J. Chem. Phys. 139, 184504 (2013)]. The resulting phase diagram is consistent with the liquid-liquid phase transition hypothesis. At the same time, the glass phase diagram is sensitive to sample preparation, such as heating or compression rates. Interestingly, at least for the rates explored, our results suggest that the LDA-to-liquid (HDA-to-liquid) and LDA-to-HDA (HDA-to-LDA) transformation lines on heating are related

  15. GLASS FIBER REINFORCED PLASTICS,

    DTIC Science & Technology

    Contents: Fibrous glass fillers Binders used in the glass plastic industry Method of manufacturing glass plastics and glass plastic articles Properties of fiberglass Primary areas for use of glass fibre reinforced plastics

  16. Machine vision for digital microfluidics

    NASA Astrophysics Data System (ADS)

    Shin, Yong-Jun; Lee, Jeong-Bong

    2010-01-01

    Machine vision is widely used in an industrial environment today. It can perform various tasks, such as inspecting and controlling production processes, that may require humanlike intelligence. The importance of imaging technology for biological research or medical diagnosis is greater than ever. For example, fluorescent reporter imaging enables scientists to study the dynamics of gene networks with high spatial and temporal resolution. Such high-throughput imaging is increasingly demanding the use of machine vision for real-time analysis and control. Digital microfluidics is a relatively new technology with expectations of becoming a true lab-on-a-chip platform. Utilizing digital microfluidics, only small amounts of biological samples are required and the experimental procedures can be automatically controlled. There is a strong need for the development of a digital microfluidics system integrated with machine vision for innovative biological research today. In this paper, we show how machine vision can be applied to digital microfluidics by demonstrating two applications: machine vision-based measurement of the kinetics of biomolecular interactions and machine vision-based droplet motion control. It is expected that digital microfluidics-based machine vision system will add intelligence and automation to high-throughput biological imaging in the future.

  17. Realism and Perspectivism: a Reevaluation of Rival Theories of Spatial Vision.

    NASA Astrophysics Data System (ADS)

    Thro, E. Broydrick

    1990-01-01

    My study reevaluates two theories of human space perception, a trigonometric surveying theory I call perspectivism and a "scene recognition" theory I call realism. Realists believe that retinal image geometry can supply no unambiguous information about an object's size and distance--and that, as a result, viewers can locate objects in space only by making discretionary interpretations based on familiar experience of object types. Perspectivists, in contrast, think viewers can disambiguate object sizes/distances on the basis of retinal image information alone. More specifically, they believe the eye responds to perspective image geometry with an automatic trigonometric calculation that not only fixes the directions and shapes, but also roughly fixes the sizes and distances of scene elements in space. Today this surveyor theory has been largely superceded by the realist approach, because most vision scientists believe retinal image geometry is ambiguous about the scale of space. However, I show that there is a considerable body of neglected evidence, both past and present, tending to call this scale ambiguity claim into question. I maintain that this evidence against scale ambiguity could hardly be more important, if one considers its subversive implications for the scene recognition theory that is not only today's reigning approach to spatial vision, but also the foundation for computer scientists' efforts to create space-perceiving robots. If viewers were deemed to be capable of automatic surveying calculations, the discretionary scene recognition theory would lose its main justification. Clearly, it would be difficult for realists to maintain that we viewers rely on scene recognition for space perception in spite of our ability to survey. And in reality, as I show, the surveyor theory does a much better job of describing the everyday space we viewers actually see--a space featuring stable, unambiguous relationships among scene elements, and a single horizon and

  18. Retrieving the ground state of spin glasses using thermal noise: Performance of quantum annealing at finite temperatures.

    PubMed

    Nishimura, Kohji; Nishimori, Hidetoshi; Ochoa, Andrew J; Katzgraber, Helmut G

    2016-09-01

    We study the problem to infer the ground state of a spin-glass Hamiltonian using data from another Hamiltonian with interactions disturbed by noise from the original Hamiltonian, motivated by the ground-state inference in quantum annealing on a noisy device. It is shown that the average Hamming distance between the inferred spin configuration and the true ground state is minimized when the temperature of the noisy system is kept at a finite value, and not at zero temperature. We present a spin-glass generalization of a well-established result that the ground state of a purely ferromagnetic Hamiltonian is best inferred at a finite temperature in the sense of smallest Hamming distance when the original ferromagnetic interactions are disturbed by noise. We use the numerical transfer-matrix method to establish the existence of an optimal finite temperature in one- and two-dimensional systems. Our numerical results are supported by mean-field calculations, which give an explicit expression of the optimal temperature to infer the spin-glass ground state as a function of variances of the distributions of the original interactions and the noise. The mean-field prediction is in qualitative agreement with numerical data. Implications on postprocessing of quantum annealing on a noisy device are discussed.

  19. Intermediate addition multifocals provide safe stair ambulation with adequate 'short-term' reading.

    PubMed

    Elliott, David B; Hotchkiss, John; Scally, Andrew J; Foster, Richard; Buckley, John G

    2016-01-01

    A recent randomised controlled trial indicated that providing long-term multifocal wearers with a pair of distance single-vision spectacles for use outside the home reduced falls risk in active older people. However, it also found that participants disliked continually switching between using two pairs of glasses and adherence to the intervention was poor. In this study we determined whether intermediate addition multifocals (which could be worn most of the time inside and outside the home and thus avoid continual switching) could provide similar gait safety on stairs to distance single vision spectacles whilst also providing adequate 'short-term' reading and near vision. Fourteen healthy long-term multifocal wearers completed stair ascent and descent trials over a 3-step staircase wearing intermediate and full addition bifocals and progression-addition lenses (PALs) and single-vision distance spectacles. Gait safety/caution was assessed using foot clearance measurements (toe on ascent, heel on descent) over the step edges and ascent and descent duration. Binocular near visual acuity, critical print size and reading speed were measured using Bailey-Lovie near charts and MNRead charts at 40 cm. Gait safety/caution measures were worse with full addition bifocals and PALs compared to intermediate bifocals and PALs. The intermediate PALs provided similar gait ascent/descent measures to those with distance single-vision spectacles. The intermediate addition PALs also provided good reading ability: Near word acuity and MNRead critical print size were better with the intermediate addition PALs than with the single-vision lenses (p < 0.0001), with a mean near visual acuity of 0.24 ± 0.13 logMAR (~N5.5) which is satisfactory for most near vision tasks when performed for a short period of time. The better ability to 'spot read' with the intermediate addition PALs compared to single-vision spectacles suggests that elderly individuals might better comply with the use of

  20. Auditory distance perception in humans: a review of cues, development, neuronal bases, and effects of sensory loss.

    PubMed

    Kolarik, Andrew J; Moore, Brian C J; Zahorik, Pavel; Cirstea, Silvia; Pardhan, Shahina

    2016-02-01

    Auditory distance perception plays a major role in spatial awareness, enabling location of objects and avoidance of obstacles in the environment. However, it remains under-researched relative to studies of the directional aspect of sound localization. This review focuses on the following four aspects of auditory distance perception: cue processing, development, consequences of visual and auditory loss, and neurological bases. The several auditory distance cues vary in their effective ranges in peripersonal and extrapersonal space. The primary cues are sound level, reverberation, and frequency. Nonperceptual factors, including the importance of the auditory event to the listener, also can affect perceived distance. Basic internal representations of auditory distance emerge at approximately 6 months of age in humans. Although visual information plays an important role in calibrating auditory space, sensorimotor contingencies can be used for calibration when vision is unavailable. Blind individuals often manifest supranormal abilities to judge relative distance but show a deficit in absolute distance judgments. Following hearing loss, the use of auditory level as a distance cue remains robust, while the reverberation cue becomes less effective. Previous studies have not found evidence that hearing-aid processing affects perceived auditory distance. Studies investigating the brain areas involved in processing different acoustic distance cues are described. Finally, suggestions are given for further research on auditory distance perception, including broader investigation of how background noise and multiple sound sources affect perceived auditory distance for those with sensory loss.

  1. Structure of semiconducting versus fast-ion conducting glasses in the Ag-Ge-Se system.

    PubMed

    Zeidler, Anita; Salmon, Philip S; Whittaker, Dean A J; Piarristeguy, Andrea; Pradel, Annie; Fischer, Henry E; Benmore, Chris J; Gulbiten, Ozgur

    2018-01-01

    The transition from a semiconductor to a fast-ion conductor with increasing silver content along the Ag x (Ge 0.25 Se 0.75 ) (100- x ) tie line (0≤ x ≤25) was investigated on multiple length scales by employing a combination of electric force microscopy, X-ray diffraction, and neutron diffraction. The microscopy results show separation into silver-rich and silver-poor phases, where the Ag-rich phase percolates at the onset of fast-ion conductivity. The method of neutron diffraction with Ag isotope substitution was applied to the x =5 and x =25 compositions, and the results indicate an evolution in structure of the Ag-rich phase with change of composition. The Ag-Se nearest-neighbours are distributed about a distance of 2.64(1) Å, and the Ag-Se coordination number increases from 2.6(3) at x =5 to 3.3(2) at x =25. For x =25, the measured Ag-Ag partial pair-distribution function gives 1.9(2) Ag-Ag nearest-neighbours at a distance of 3.02(2) Å. The results show breakage of Se-Se homopolar bonds as silver is added to the Ge 0.25 Se 0.75 base glass, and the limit of glass-formation at x ≃28 coincides with an elimination of these bonds. A model is proposed for tracking the breakage of Se-Se homopolar bonds as silver is added to the base glass.

  2. Structure of semiconducting versus fast-ion conducting glasses in the Ag–Ge–Se system

    PubMed Central

    2018-01-01

    The transition from a semiconductor to a fast-ion conductor with increasing silver content along the Agx(Ge0.25Se0.75)(100−x) tie line (0≤x≤25) was investigated on multiple length scales by employing a combination of electric force microscopy, X-ray diffraction, and neutron diffraction. The microscopy results show separation into silver-rich and silver-poor phases, where the Ag-rich phase percolates at the onset of fast-ion conductivity. The method of neutron diffraction with Ag isotope substitution was applied to the x=5 and x=25 compositions, and the results indicate an evolution in structure of the Ag-rich phase with change of composition. The Ag–Se nearest-neighbours are distributed about a distance of 2.64(1) Å, and the Ag–Se coordination number increases from 2.6(3) at x=5 to 3.3(2) at x=25. For x=25, the measured Ag–Ag partial pair-distribution function gives 1.9(2) Ag–Ag nearest-neighbours at a distance of 3.02(2) Å. The results show breakage of Se–Se homopolar bonds as silver is added to the Ge0.25Se0.75 base glass, and the limit of glass-formation at x≃28 coincides with an elimination of these bonds. A model is proposed for tracking the breakage of Se–Se homopolar bonds as silver is added to the base glass. PMID:29410843

  3. Understanding and preventing computer vision syndrome.

    PubMed

    Loh, Ky; Redd, Sc

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  4. Spheroidization of glass powders for glass ionomer cements.

    PubMed

    Gu, Y W; Yap, A U J; Cheang, P; Kumar, R

    2004-08-01

    Commercial angular glass powders were spheroidized using both the flame spraying and inductively coupled radio frequency plasma spraying techniques. Spherical powders with different particle size distributions were obtained after spheroidization. The effects of spherical glass powders on the mechanical properties of glass ionomer cements (GICs) were investigated. Results showed that the particle size distribution of the glass powders had a significant influence on the mechanical properties of GICs. Powders with a bimodal particle size distribution ensured a high packing density of glass ionomer cements, giving relatively high mechanical properties of GICs. GICs prepared by flame-spheroidized powders showed low strength values due to the loss of fine particles during flame spraying, leading to a low packing density and few metal ions reacting with polyacrylic acid to form cross-linking. GICs prepared by the nano-sized powders showed low strength because of the low bulk density of the nano-sized powders and hence low powder/liquid ratio of GICs.

  5. Predictors of vision impairment in Multiple Sclerosis.

    PubMed

    Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo

    2018-01-01

    Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.

  6. Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia.

    PubMed

    Cardona, Genís; López, Sílvia

    2016-01-01

    To determine working distance, pupil diameter and illumination in real life conditions in a sample of presbyopic participants performing habitual tasks. A total of 59 presbyopic subjects (aged between 45 and 63 years) with different occupational backgrounds participated in the study. Participants were first interviewed regarding their habitual tasks with the aid of an ad hoc questionnaire, following which in-office photopic and mesopic pupil diameter was determined. Pupil diameter was also evaluated while participants conducted each of the self-reported habitual tasks by taking a photograph, which was later submitted to image analysis. In addition, working distance was determined with a measuring tape and the illumination that reached the pupil during each of the different tasks was measured, in lux, with a light meter. The four most common habitual tasks were computer use, reading, sewing and sports. A high intersubject variability was found in pupil diameter, working distance and illumination conditions while conducting the same task. Statistically significant differences were found between the in-office measured photopic and mesopic pupil diameters and those obtained while participants were conducting their habitual tasks in real life conditions (all p<0.001). Potential multifocal contact lens users may present with different ages, different jobs or hobbies and different preferences regarding lighting conditions and working distances. This results in different pupil size, even within the same task. This information may be critical when selecting a particular lens design and add power. Eye care practitioners are therefore advised to assess pupil diameter in real life conditions. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  7. Availability of vision and tactile gating: vision enhances tactile sensitivity.

    PubMed

    Colino, Francisco L; Lee, Ji-Hang; Binsted, Gordon

    2017-01-01

    A multitude of events bombard our sensory systems at every moment of our lives. Thus, it is important for the sensory and motor cortices to gate unimportant events. Tactile suppression is a well-known phenomenon defined as a reduced ability to detect tactile events on the skin before and during movement. Previous experiments (Buckingham et al. in Exp Brain Res 201(3):411-419, 2010; Colino et al. in Physiol Rep 2(3):e00267, 2014) found detection rates decrease just prior to and during finger abduction and decrease according to the proximity of the moving effector. However, what effect does vision have on tactile gating? There is ample evidence (see Serino and Haggard in Neurosci Biobehav Rev 34:224-236, 2010) observing increased tactile acuity when participants see their limbs. The present study examined how tactile detection changes in response to visual condition (vision/no vision). Ten human participants used their right hand to reach and grasp a cylinder. Tactors were attached to the index finger and the forearm of both the right and left arm and vibrated at various epochs relative to a "go" tone. Results replicate previous findings from our laboratory (Colino et al. in Physiol Rep 2(3):e00267, 2014). Also, tactile acuity decreased when participants did not have vision. These results indicate that the vision affects the somatosensation via inputs from parietal areas (Konen and Haggard in Cereb Cortex 24(2):501-507, 2014) but does so in a reach-to-grasp context.

  8. Superintendent Leadership and Districtwide Vision.

    ERIC Educational Resources Information Center

    Lilly, Edward R.

    The concept of superintendent "vision" as a key element of effective leadership is discussed in this paper, which develops a framework for understanding the creation of vision, its implementation and articulation, and organizational impact. Vision differs from strategy in that it represents a set of beliefs about the school district's aspiring…

  9. Computer vision syndrome in presbyopia and beginning presbyopia: effects of spectacle lens type.

    PubMed

    Jaschinski, Wolfgang; König, Mirjam; Mekontso, Tiofil M; Ohlendorf, Arne; Welscher, Monique

    2015-05-01

    This office field study investigated the effects of different types of spectacle lenses habitually worn by computer users with presbyopia and in the beginning stages of presbyopia. Computer vision syndrome was assessed through reported complaints and ergonomic conditions. A questionnaire regarding the type of habitually worn near-vision lenses at the workplace, visual conditions and the levels of different types of complaints was administered to 175 participants aged 35 years and older (mean ± SD: 52.0 ± 6.7 years). Statistical factor analysis identified five specific aspects of the complaints. Workplace conditions were analysed based on photographs taken in typical working conditions. In the subgroup of 25 users between the ages of 36 and 57 years (mean 44 ± 5 years), who wore distance-vision lenses and performed more demanding occupational tasks, the reported extents of 'ocular strain', 'musculoskeletal strain' and 'headache' increased with the daily duration of computer work and explained up to 44 per cent of the variance (rs = 0.66). In the other subgroups, this effect was smaller, while in the complete sample (n = 175), this correlation was approximately rs = 0.2. The subgroup of 85 general-purpose progressive lens users (mean age 54 years) adopted head inclinations that were approximately seven degrees more elevated than those of the subgroups with single vision lenses. The present questionnaire was able to assess the complaints of computer users depending on the type of spectacle lenses worn. A missing near-vision addition among participants in the early stages of presbyopia was identified as a risk factor for complaints among those with longer daily durations of demanding computer work. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  10. Optical and Physical Investigations of Lanthanum Bismuth Borate glasses doped with Ho2O3

    NASA Astrophysics Data System (ADS)

    Ramesh, P.; Jagannath, G.; Eraiah, B.; Kokila, M. K.

    2018-02-01

    Holmium doped 10La2O3-15Bi2O3-(75-x) B2O3 (Ho3+: LBB) glasses have been prepared by melt quench technique and the impact of holmium ions concentration on optical and physical properties of present glasses have been examined. Ho3+ dependent density, molar volume, refractive index, rare earth ion concentration, polaron radius, inter ionic distance, field strength and energy band gap are calculated and tabulated. Amorphous nature of the all glasses has been confirmed by XRD patterns. The room temperature (RT) Uv-Vis absorption spectrum doped with 1 mol% of Ho2O3 exhibit eight prominent bands centred at 895, 641, 537, 486, 472, 467, 451 and 416 due to transition between ground state to various excited states. The results show that, the density is increases and molar volume of the glasses is decreases with an increase in Ho2O3 concentration and consequently generate more non-bridging oxygen (NBOs) in the glass matrix. The Urbach energy is increases with holmium concentration which exemplifies the degree of disorder present in the LBB glasses. The considerable increase in field strength observed in present glasses is attributed to occurrence of strong bridge between Ho3+ and B- ions and this strong bridge is possibly due to the displacement between Ho3+ and oxygen atoms which are generated from the conversion BO3-BO4 units.

  11. Picture Wall (Glass Structures)

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Photo shows a subway station in Toronto, Ontario, which is entirely glass-enclosed. The all-glass structure was made possible by a unique glazing concept developed by PPG Industries, Pittsburgh, Pennsylvania, one of the largest U.S. manufacturers of flat glass. In the TVS glazing system, transparent glass "fins" replace conventional vertical support members used to provide support for wind load resistance. For stiffening, silicone sealant bonds the fins to adjacent glass panels. At its glass research center near Pittsburgh, PPG Industries uses the NASTRAN computer program to analyze the stability of enclosures made entirely of glass. The company also uses NASTRAN to simulate stresses on large containers of molten glass and to analyze stress effects of solar heating on flat glass.

  12. Student Satisfaction: A Distance Learning Model for Training Teachers of Students with Visual Impairments in New York State. Research Report

    ERIC Educational Resources Information Center

    Trief, Ellen; Decker, Lisa M.; Ryan, Daniel J.

    2004-01-01

    Since 1920, the Hadley School for the Blind in Winnetka, Illinois, has provided distance learning (via correspondence courses) to individuals who are visually impaired (that is, are blind or have low vision) and their families to support the acquisition of specialized skills and to attain the knowledge needed for full participation in life…

  13. Bioactivity of Sodium Free Fluoride Containing Glasses and Glass-Ceramics

    PubMed Central

    Chen, Xiaojing; Chen, Xiaohui; Brauer, Delia S.; Wilson, Rory M.; Hill, Robert G.; Karpukhina, Natalia

    2014-01-01

    The bioactivity of a series of fluoride-containing sodium-free calcium and strontium phosphosilicate glasses has been tested in vitro. Glasses with high fluoride content were partially crystallised to apatite and other fluoride-containing phases. The bioactivity study was carried out in Tris and SBF buffers, and apatite formation was monitored by XRD, FTIR and solid state NMR. Ion release in solutions has been measured using ICP-OES and fluoride-ion selective electrode. The results show that glasses with low amounts of fluoride that were initially amorphous degraded rapidly in Tris buffer and formed apatite as early as 3 h after immersion. The apatite was identified as fluorapatite by 19F MAS-NMR after 6 h of immersion. Glass degradation and apatite formation was significantly slower in SBF solution compared to Tris. On immersion of the partially crystallised glasses, the fraction of apatite increased at 3 h compared to the amount of apatite prior to the treatment. Thus, partial crystallisation of the glasses has not affected bioactivity significantly. Fast dissolution of the amorphous phase was also indicated. There was no difference in kinetics between Tris and SBF studies when the glass was partially crystallised to apatite before immersion. Two different mechanisms of apatite formation for amorphous or partially crystallised glasses are discussed. PMID:28788139

  14. Innovative intelligent technology of distance learning for visually impaired people

    NASA Astrophysics Data System (ADS)

    Samigulina, Galina; Shayakhmetova, Assem; Nuysuppov, Adlet

    2017-12-01

    The aim of the study is to develop innovative intelligent technology and information systems of distance education for people with impaired vision (PIV). To solve this problem a comprehensive approach has been proposed, which consists in the aggregate of the application of artificial intelligence methods and statistical analysis. Creating an accessible learning environment, identifying the intellectual, physiological, psychophysiological characteristics of perception and information awareness by this category of people is based on cognitive approach. On the basis of fuzzy logic the individually-oriented learning path of PIV is con- structed with the aim of obtaining high-quality engineering education with modern equipment in the joint use laboratories.

  15. Vision Screening For Head Starters.

    ERIC Educational Resources Information Center

    Foley, Celia

    To determine which children in the Head Start program may have vision problems, Head Start teachers and staff do vision "screening." This booklet demonstrates how to do the screening using the Snellen "E Chart." Trouble signs that the test administrator should be aware of are listed, and vision scores are explained simply.…

  16. Open and Distance Education Systems: Do They Enhance Graduates' Soft Skills? The Results from 2009 Universitas Terbuka Tracer Study

    ERIC Educational Resources Information Center

    Ratnaningsih, Dewi Juliah

    2013-01-01

    The vision and mission of Universitas Terbuka (UT) is to become a highly qualified open and distance education institution and to provide higher education access to all communities. Graduates of UT are expected to acquire adequate knowledge, hard skills and soft skills. Soft skills play important roles in the world of work. The aim of this article…

  17. Magnetic Glass Ceramics by Sintering of Borosilicate Glass and Inorganic Waste.

    PubMed

    Ponsot, Inès M M M; Pontikes, Yiannis; Baldi, Giovanni; Chinnam, Rama K; Detsch, Rainer; Boccaccini, Aldo R; Bernardo, Enrico

    2014-07-31

    Ceramics and glass ceramics based on industrial waste have been widely recognized as competitive products for building applications; however, there is a great potential for such materials with novel functionalities. In this paper, we discuss the development of magnetic sintered glass ceramics based on two iron-rich slags, coming from non-ferrous metallurgy and recycled borosilicate glass. The substantial viscous flow of the glass led to dense products for rapid treatments at relatively low temperatures (900-1000 °C), whereas glass/slag interactions resulted in the formation of magnetite crystals, providing ferrimagnetism. Such behavior could be exploited for applying the obtained glass ceramics as induction heating plates, according to preliminary tests (showing the rapid heating of selected samples, even above 200 °C). The chemical durability and safety of the obtained glass ceramics were assessed by both leaching tests and cytotoxicity tests.

  18. Reading Digital with Low Vision

    PubMed Central

    Legge, Gordon E.

    2017-01-01

    Reading difficulty is a major consequence of vision loss for more than four million Americans with low vision. Difficulty in accessing print imposes obstacles to education, employment, social interaction and recreation. In recent years, research in vision science has made major strides in understanding the impact of low vision on reading, and the dependence of reading performance on text properties. The ongoing transition to the production and distribution of digital documents brings about new opportunities for people with visual impairment. Digital documents on computers and mobile devices permit customization of print size, spacing, font style, contrast polarity and page layout to optimize reading displays for people with low vision. As a result, we now have unprecedented opportunities to adapt text format to meet the needs of visually impaired readers. PMID:29242668

  19. Efficiency of Moderated Neutron Lithium Glass Detectors Using Monte Carlo Techniques

    NASA Astrophysics Data System (ADS)

    James, Brian

    2011-10-01

    Due to national security concerns over the smuggling of special nuclear materials and the small supply of He-3 for use in neutron detectors, there is a great need for a new kind of neutron detector. Using Monte Carlo techniques I have been studying the use of lithium glass in varying configurations for neutron detectors. My research has included the effects of using a detector with two thin sheets of lithium at varying distances apart. I have also researched the effects of varying amounts of shielding a californium source with varying amounts of water. This is important since shielding would likely be used to make nuclear material more difficult to detect. The addition of one sheet of lithium-6 glass on the front surface of the detector significantly improves the efficiency for the detection of neutrons from a moderated fission source.

  20. Vision Impairment and Blindness

    MedlinePlus

    ... books can make life easier. There are also devices to help those with no vision, like text-reading software and braille books. The sooner vision loss or eye disease is found and treated, the greater your ...

  1. The Perfect Glass Paradigm: Disordered Hyperuniform Glasses Down to Absolute Zero.

    PubMed

    Zhang, G; Stillinger, F H; Torquato, S

    2016-11-28

    Rapid cooling of liquids below a certain temperature range can result in a transition to glassy states. The traditional understanding of glasses includes their thermodynamic metastability with respect to crystals. However, here we present specific examples of interactions that eliminate the possibilities of crystalline and quasicrystalline phases, while creating mechanically stable amorphous glasses down to absolute zero temperature. We show that this can be accomplished by introducing a new ideal state of matter called a "perfect glass". A perfect glass represents a soft-interaction analog of the maximally random jammed (MRJ) packings of hard particles. These latter states can be regarded as the epitome of a glass since they are out of equilibrium, maximally disordered, hyperuniform, mechanically rigid with infinite bulk and shear moduli, and can never crystallize due to configuration-space trapping. Our model perfect glass utilizes two-, three-, and four-body soft interactions while simultaneously retaining the salient attributes of the MRJ state. These models constitute a theoretical proof of concept for perfect glasses and broaden our fundamental understanding of glass physics. A novel feature of equilibrium systems of identical particles interacting with the perfect-glass potential at positive temperature is that they have a non-relativistic speed of sound that is infinite.

  2. Glass transition temperature and topological constraints of sodium borophosphate glass-forming liquids.

    PubMed

    Jiang, Qi; Zeng, Huidan; Liu, Zhao; Ren, Jing; Chen, Guorong; Wang, Zhaofeng; Sun, Luyi; Zhao, Donghui

    2013-09-28

    Sodium borophosphate glasses exhibit intriguing mixed network former effect, with the nonlinear compositional dependence of their glass transition temperature as one of the most typical examples. In this paper, we establish the widely applicable topological constraint model of sodium borophosphate mixed network former glasses to explain the relationship between the internal structure and nonlinear changes of glass transition temperature. The application of glass topology network was discussed in detail in terms of the unified methodology for the quantitative distribution of each coordinated boron and phosphorus units and glass transition temperature dependence of atomic constraints. An accurate prediction of composition scaling of the glass transition temperature was obtained based on topological constraint model.

  3. Magnetic Glass Ceramics by Sintering of Borosilicate Glass and Inorganic Waste

    PubMed Central

    Ponsot, Inès M. M. M.; Pontikes, Yiannis; Baldi, Giovanni; Chinnam, Rama K.; Detsch, Rainer; Boccaccini, Aldo R.; Bernardo, Enrico

    2014-01-01

    Ceramics and glass ceramics based on industrial waste have been widely recognized as competitive products for building applications; however, there is a great potential for such materials with novel functionalities. In this paper, we discuss the development of magnetic sintered glass ceramics based on two iron-rich slags, coming from non-ferrous metallurgy and recycled borosilicate glass. The substantial viscous flow of the glass led to dense products for rapid treatments at relatively low temperatures (900–1000 °C), whereas glass/slag interactions resulted in the formation of magnetite crystals, providing ferrimagnetism. Such behavior could be exploited for applying the obtained glass ceramics as induction heating plates, according to preliminary tests (showing the rapid heating of selected samples, even above 200 °C). The chemical durability and safety of the obtained glass ceramics were assessed by both leaching tests and cytotoxicity tests. PMID:28788146

  4. Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering

    PubMed Central

    Gerhardt, Lutz-Christian; Boccaccini, Aldo R.

    2010-01-01

    Traditionally, bioactive glasses have been used to fill and restore bone defects. More recently, this category of biomaterials has become an emerging research field for bone tissue engineering applications. Here, we review and discuss current knowledge on porous bone tissue engineering scaffolds on the basis of melt-derived bioactive silicate glass compositions and relevant composite structures. Starting with an excerpt on the history of bioactive glasses, as well as on fundamental requirements for bone tissue engineering scaffolds, a detailed overview on recent developments of bioactive glass and glass-ceramic scaffolds will be given, including a summary of common fabrication methods and a discussion on the microstructural-mechanical properties of scaffolds in relation to human bone (structure-property and structure-function relationship). In addition, ion release effects of bioactive glasses concerning osteogenic and angiogenic responses are addressed. Finally, areas of future research are highlighted in this review. PMID:28883315

  5. Evolution of colour vision in mammals.

    PubMed

    Jacobs, Gerald H

    2009-10-12

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision.

  6. Evolution of colour vision in mammals

    PubMed Central

    Jacobs, Gerald H.

    2009-01-01

    Colour vision allows animals to reliably distinguish differences in the distributions of spectral energies reaching the eye. Although not universal, a capacity for colour vision is sufficiently widespread across the animal kingdom to provide prima facie evidence of its importance as a tool for analysing and interpreting the visual environment. The basic biological mechanisms on which vertebrate colour vision ultimately rests, the cone opsin genes and the photopigments they specify, are highly conserved. Within that constraint, however, the utilization of these basic elements varies in striking ways in that they appear, disappear and emerge in altered form during the course of evolution. These changes, along with other alterations in the visual system, have led to profound variations in the nature and salience of colour vision among the vertebrates. This article concerns the evolution of colour vision among the mammals, viewing that process in the context of relevant biological mechanisms, of variations in mammalian colour vision, and of the utility of colour vision. PMID:19720656

  7. Simple laser vision sensor calibration for surface profiling applications

    NASA Astrophysics Data System (ADS)

    Abu-Nabah, Bassam A.; ElSoussi, Adnane O.; Al Alami, Abed ElRahman K.

    2016-09-01

    Due to the relatively large structures in the Oil and Gas industry, original equipment manufacturers (OEMs) have been implementing custom-designed laser vision sensor (LVS) surface profiling systems as part of quality control in their manufacturing processes. The rough manufacturing environment and the continuous movement and misalignment of these custom-designed tools adversely affect the accuracy of laser-based vision surface profiling applications. Accordingly, Oil and Gas businesses have been raising the demand from the OEMs to implement practical and robust LVS calibration techniques prior to running any visual inspections. This effort introduces an LVS calibration technique representing a simplified version of two known calibration techniques, which are commonly implemented to obtain a calibrated LVS system for surface profiling applications. Both calibration techniques are implemented virtually and experimentally to scan simulated and three-dimensional (3D) printed features of known profiles, respectively. Scanned data is transformed from the camera frame to points in the world coordinate system and compared with the input profiles to validate the introduced calibration technique capability against the more complex approach and preliminarily assess the measurement technique for weld profiling applications. Moreover, the sensitivity to stand-off distances is analyzed to illustrate the practicality of the presented technique.

  8. Chalcogenide Glasses. Part 3. Chalcogenide Glass-Forming Systems.

    DTIC Science & Technology

    1986-02-01

    34.L •. - . . . . . . . . ....... * .- . -.. . .. .. 8. Ti - As - S 31 9. As - Sb - S and As - Sb - Se 37 10. As - Halogen - (S, Se or Te) 40 11. As...Glass Forming Region and Tg in Ge-Sb-Se System 54[Ref. 40 ] 30 Glass Forming Region in Ge-Bi-S System [Ref.78] 55 31 Glass Forming Region in Ge-Bi-Se...poise), indicating the presence of tellurium chains. * p.° ~ -7 .. . *. 2. . * . . -~ ?’ ~ ~ - .. -~. r; - - - -•.~ ~ ~ ~ ~ * . 40 However, it rapidly

  9. Compact pulsed high-energy Er:glass laser

    NASA Astrophysics Data System (ADS)

    Wan, Peng; Liu, Jian

    2012-03-01

    Bulk Erbium-doped lasers are widely used for long-distance telemetry and ranging. In some applications such as coherent Doppler radars, laser outputs with a relatively long pulse width, good beam profile and pulse shape are required. High energy Q-switched Er:glass lasers were demonstrated by use of electro-optic (E/O) Q-switching or frustrated total internal reflection (FTIR) Q-switching. However, the output pulse durations in these lasers were fixed to relatively small values and extremely hard to tune. We report here on developing a novel and compact Q-switched Er:Yb co-doped phosphate glass laser at an eye-safe wavelength of 1.5 μm. A rotating mirror was used as a Q-switch. Co-linear pump scheme was used to maintain a good output beam profile. Near-perfect Gaussian temporal shape was obtained in our experiment. By changing motor rotation speed, pulse duration was tunable and up to 240 ns was achieved. In our preliminary experiment, output pulse energies of 44 mJ and 4.5 mJ were obtained in free-running and Q-switched operation modes respectively.

  10. Glass formation, properties, and structure of soda-yttria-silicate glasses

    NASA Technical Reports Server (NTRS)

    Angel, Paul W.; Hann, Raiford E.

    1991-01-01

    The glass formation region of the soda yttria silicate system was determined. The glasses within this region were measured to have a density of 2.4 to 3.1 g/cu cm, a refractive index of 1.50 to 1.60, a coefficient of thermal expansion of 7 x 10(exp -6)/C, softening temperatures between 500 and 780 C, and Vickers hardness values of 3.7 to 5.8 GPa. Aqueous chemical durability measurements were made on select glass compositions while infrared transmission spectra were used to study the glass structure and its effect on glass properties. A compositional region was identified which exhibited high thermal expansion, high softening temperatures, and good chemical durability.

  11. Production of glass or glass-ceramic to metal seals with the application of pressure

    DOEpatents

    Kelly, Michael D.; Kramer, Daniel P.

    1987-11-10

    In a process for preparing a glass or glass-ceramic to metal seal comprising contacting the glass with the metal and heat-treating the glass and metal under conditions whereby the glass to metal seal is effected and, optionally, the glass is converted to a glass-ceramic, an improvement comprises carrying out the heat-treating step using hot isostatic pressing.

  12. Production of glass or glass-ceramic to metal seals with the application of pressure

    DOEpatents

    Kelly, M.D.; Kramer, D.P.

    1985-01-04

    In a process for preparing a glass or glass-ceramic to metal seal comprising contacting the glass with the metal and heat-treating the glass and metal under conditions whereby the glass to metal seal is effected and, optionally, the glass is converted to a glass-ceramic, an improvement comprises carrying out the heat-treating step using hot isostatic pressing.

  13. The Pedagogy of Teaching Educational Vision: A Vision Coach's Field Notes about Leaders as Learners

    ERIC Educational Resources Information Center

    Schein, Jeffrey

    2009-01-01

    The emerging field of educational visioning is full of challenges and phenomena worthy of careful analysis and documentation. A relatively neglected phenomenon is the learning curve of the leaders (often lay leaders) involved in the visioning process. This article documents a range of experiences of the author serving as a vision coach to five…

  14. Friction behavior of glass and metals in contact with glass in various environments

    NASA Technical Reports Server (NTRS)

    Buckley, D. H.

    1973-01-01

    Sliding friction experiments have been conducted for heat-resistant glass and metals in contact with glass. These experiments were conducted in various environments including vacuum, moist air, dry air, octane, and stearic acid in hexadecane. Glass exhibited a higher friction force in moist air than it did in vacuum when in sliding contact with itself. The metals, aluminum, iron, and gold, all exhibited the same friction coefficient when sliding on glass in vacuum as glass sliding on glass. Gold-to-glass contacts were extremely sensitive to the environment despite the relative chemical inertness of gold.

  15. Local dynamics of glass-forming polystyrene thin films from atomistic simulation

    NASA Astrophysics Data System (ADS)

    Zhou, Yuxing; Milner, Scott

    Despite a wide technological application ranging from protective coatings to organic solar cells, there still no consensus on the mechanism for the glass transition in polymer thin films a manifestation of the infamous glass problem under confinement. Many experimental and computational studies have observed a large deviation of nanoscale dynamical properties in thin films from the corresponding properties in bulk. In this work, we perform extensive united-atom simulations on atactic polystyrene free-standing thin films near the glass transition temperature and focus on the effect of free surface on the local dynamics. We study the segmental dynamics as a function of distance from the surface for different temperatures, from which relaxation time and thereby local Tg is obtained for each layer. We find the dynamics near free surface is not only enhanced but becomes less strongly temperature dependent as Tg is approached compared to the bulk. We find an increasing length scale associated with mobility propagation from the free surface as temperature decreases, but no correlation between local structure and enhanced relaxation rates near the surface, consistent with studies on bead-spring chains.

  16. Effects of glass scraps powder and glass fiber on mechanical properties of polyester composites

    NASA Astrophysics Data System (ADS)

    Sonsakul, K.; Boongsood, W.

    2017-11-01

    One concern in bus manufacturing is the high cost of glass fiber reinforced in polyester composites parts. The composites of glass fiber and polyester are low elongation and high strength, and glass scraps powder displays high hardness and good chemical compatibility with the polymer matrix and glass fiber. This research aimed to study the effects of glass scraps powder and glass fiber on mechanical performance of polyester composites. Glass fiber was randomly oriented fiber and used as new. Glass scraps were obtained from a bus factory and crushed to powder sizes of 120 and 240 μm by a ball mill. Polyester composites were prepared using Vacuum Infusion Process (VIP).Polyester reinforced with 3 layers of glass fiber was an initial condition. Then, one layer of glass fiber was replaced with glass scraps powder. Flexural strength, tensile strength, impact strength and hardness of the polyester composites were determined. Hardness was increased with a combination of smaller size and higher volume of glass scraps powder. Pictures of specimens obtained by using scanning electron microscope (SEM) confirmed that the powder of glass scraps packed in the layers of glass fiber in polyester composites.

  17. UAS stealth: target pursuit at constant distance using a bio-inspired motion camouflage guidance law.

    PubMed

    Strydom, Reuben; Srinivasan, Mandyam V

    2017-09-21

    The aim of this study is to derive a guidance law by which an unmanned aerial system(s) (UAS) can pursue a moving target at a constant distance, while concealing its own motion. We derive a closed-form solution for the trajectory of the UAS by imposing two key constraints: (1) the shadower moves in such a way as to be perceived as a stationary object by the shadowee, and (2) the distance between the shadower and shadowee is kept constant. Additionally, the theory presented in this paper considers constraints on the maximum achievable speed and acceleration of the shadower. Our theory is tested through Matlab simulations, which validate the camouflage strategy for both 2D and 3D conditions. Furthermore, experiments using a realistic vision-based implementation are conducted in a virtual environment, where the results demonstrate that even with noisy state information it is possible to remain well camouflaged using the constant distance motion camouflage technique.

  18. Glass Property Data and Models for Estimating High-Level Waste Glass Volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vienna, John D.; Fluegel, Alexander; Kim, Dong-Sang

    2009-10-05

    This report describes recent efforts to develop glass property models that can be used to help estimate the volume of high-level waste (HLW) glass that will result from vitrification of Hanford tank waste. The compositions of acceptable and processable HLW glasses need to be optimized to minimize the waste-form volume and, hence, to save cost. A database of properties and associated compositions for simulated waste glasses was collected for developing property-composition models. This database, although not comprehensive, represents a large fraction of data on waste-glass compositions and properties that were available at the time of this report. Glass property-composition modelsmore » were fit to subsets of the database for several key glass properties. These models apply to a significantly broader composition space than those previously publised. These models should be considered for interim use in calculating properties of Hanford waste glasses.« less

  19. Low vision and mobility scooters: the experiences of individuals with low vision who use mobility scooters.

    PubMed

    McMullan, Keri S; Butler, Mary

    2018-05-09

    Older adults with low vision are a growing population with rehabilitation needs including support with community mobility to enable community participation. Some older adults with low vision choose to use mobility scooters to mobilize within their community, but there is limited research about the use by people with low vision. This paper describes a pilot study and asks the question: what are the experiences of persons with low vision who use mobility scooters? This study gathered the experiences of four participants with low vision, aged 51 and over, who regularly use mobility scooters. Diverse methods were used including a go-along, a semi-structured interview and a new measure of functional vision for mobility called the vision-related outcomes in orientation and mobility (VROOM). Four themes were found to describe experiences: autonomy and well-being, accessibility, community interactions and self-regulation. Discussion and implications: This study was a pilot for a larger study examining self-regulation in scooter users. However, as roles emerge for health professionals and scooters, the findings also provide evidence to inform practice, because it demonstrates the complex meaning and influences on performance involved in low vision mobility scooter use. Implications for rehabilitation Scooter use supports autonomy and well-being and community connections for individuals with both mobility and visual impairments. Low vision scooter users demonstrate self-regulation of their scooter use to manage both their visual and environmental limitations. Issues of accessibility experienced by this sample affect a wider community of footpath users, emphasizing the need for councils to address inadequate infrastructure. Rehabilitators can support their low vision clients' scooter use by acknowledging issues of accessibility and promoting self-regulation strategies to manage risks and barriers.

  20. Correlating tephras and cryptotephras using glass compositional analyses and numerical and statistical methods: Review and evaluation

    NASA Astrophysics Data System (ADS)

    Lowe, David J.; Pearce, Nicholas J. G.; Jorgensen, Murray A.; Kuehn, Stephen C.; Tryon, Christian A.; Hayward, Chris L.

    2017-11-01

    preferably from the same analytical session, should be presented alongside new analytical data. In part 2 of the review, we describe, critically assess, and recommend ways in which tephras or cryptotephras can be correlated (in conjunction with other information) using numerical or statistical analyses of compositional data. Statistical methods provide a less subjective means of dealing with analytical data pertaining to tephra components (usually glass or crystals/phenocrysts) than heuristic alternatives. They enable a better understanding of relationships among the data from multiple viewpoints to be developed and help quantify the degree of uncertainty in establishing correlations. In common with other scientific hypothesis testing, it is easier to infer using such analysis that two or more tephras are different rather than the same. Adding stratigraphic, chronological, spatial, or palaeoenvironmental data (i.e. multiple criteria) is usually necessary and allows for more robust correlations to be made. A two-stage approach is useful, the first focussed on differences in the mean composition of samples, or their range, which can be visualised graphically via scatterplot matrices or bivariate plots coupled with the use of statistical tools such as distance measures, similarity coefficients, hierarchical cluster analysis (informed by distance measures or similarity or cophenetic coefficients), and principal components analysis (PCA). Some statistical methods (cluster analysis, discriminant analysis) are referred to as 'machine learning' in the computing literature. The second stage examines sample variance and the degree of compositional similarity so that sample equivalence or otherwise can be established on a statistical basis. This stage may involve discriminant function analysis (DFA), support vector machines (SVMs), canonical variates analysis (CVA), and ANOVA or MANOVA (or its two-sample special case, the Hotelling two-sample T2 test). Randomization tests can be used

  1. Stereo vision and strabismus

    PubMed Central

    Read, J C A

    2015-01-01

    Binocular stereopsis, or stereo vision, is the ability to derive information about how far away objects are, based solely on the relative positions of the object in the two eyes. It depends on both sensory and motor abilities. In this review, I briefly outline some of the neuronal mechanisms supporting stereo vision, and discuss how these are disrupted in strabismus. I explain, in some detail, current methods of assessing stereo vision and their pros and cons. Finally, I review the evidence supporting the clinical importance of such measurements. PMID:25475234

  2. Clinical colour vision tests.

    PubMed

    Dain, Stephen J

    2004-07-01

    The structure and function of the available and significant clinical colour vision tests are reviewed in the light of the needs in the clinical examination of congenital and acquired colour vision deficiencies. The tests are grouped and described as pseudo-isochromatic plates, arrangement tests, matching tests and vocational tests. The colorimetric constructions of the test types are described and the efficiency of their performance and usefulness discussed. Recommendations are made for basic and extended test batteries, when examining of congenital and acquired colour vision deficiencies in the consulting room.

  3. Case Report: Use of Sports and Performance Vision Training to Benefit a Low-vision Patient's Function.

    PubMed

    Laby, Daniel M

    2018-05-17

    Despite our inability to attenuate the course of many ocular diseases that can ultimately lead to loss or significantly decreased visual function, this report describes a potential technique to aid such patients in maximizing the use of the vision that remains. The aim of this study was to demonstrate the applicability of utilizing sports vision training to improve objective and subjective visuomotor function in a low-vision patient. A 37-year-old woman with Usher syndrome presented with reduced central visual acuity and visual field. Although we were unable to reverse the damage resulting from her diagnosis, we were able to improve the use of the remaining vision. A 27 to 31% improvement in hand-eye coordination was achieved along with a 41% improvement in object tracking and visual concentration. Most importantly, following the 14-week training period, there was also a subjective improvement in the patient's appreciation of her visual ability. The sports vision literature cites many examples in which sports vision training is useful in improving visuomotor and on-field performance. We hypothesized that these techniques may be used to aid not only athletes but also patients with low vision. Despite suffering from reduced acuity and a limited visual field, these patients often still have a significant amount of vision ability that can be used to guide motor actions. Using techniques to increase the efficient use of this remaining vision may reduce the impact of the reduced visual function and aid in activities of daily living.

  4. Laser Glass Frit Sealing for Encapsulation of Vacuum Insulation Glasses

    NASA Astrophysics Data System (ADS)

    Kind, H.; Gehlen, E.; Aden, M.; Olowinsky, A.; Gillner, A.

    Laser glass frit sealing is a joining method predestined in electronics for the sealing of engineered materials housings in dimensions of some 1 mm2 to several 10 mm2. The application field ranges from encapsulation of display panels to sensor housings. Laser glass frit sealing enables a hermetical closure excluding humidity and gas penetration. But the seam quality is also interesting for other applications requiring a hermetical sealing. One application is the encapsulation of vacuum insulation glass. The gap between two panes must be evacuated for reducing the thermal conductivity. Only an efficient encapsulating technique ensures durable tight joints of two panes for years. Laser glass frit sealing is an alternative joining method even though the material properties of soda lime glass like sensitivity to thermal stresses are much higher as known from engineered materials. An adapted thermal management of the process is necessary to prevent the thermal stresses within the pane to achieve crack free and tight glass frit seams.

  5. PsyGlass: Capitalizing on Google Glass for naturalistic data collection.

    PubMed

    Paxton, Alexandra; Rodriguez, Kevin; Dale, Rick

    2015-09-01

    As commercial technology moves further into wearable technologies, cognitive and psychological scientists can capitalize on these devices to facilitate naturalistic research designs while still maintaining strong experimental control. One such wearable technology is Google Glass (Google, Inc.: www.google.com/glass), which can present wearers with audio and visual stimuli while tracking a host of multimodal data. In this article, we introduce PsyGlass, a framework for incorporating Google Glass into experimental work that is freely available for download and community improvement over time (www.github.com/a-paxton/PsyGlass). As a proof of concept, we use this framework to investigate dual-task pressures on naturalistic interaction. The preliminary study demonstrates how designs from classic experimental psychology may be integrated in naturalistic interactive designs with emerging technologies. We close with a series of recommendations for using PsyGlass and a discussion of how wearable technology more broadly may contribute to new or adapted naturalistic research designs.

  6. What aspects of vision facilitate haptic processing?

    PubMed

    Millar, Susanna; Al-Attar, Zainab

    2005-12-01

    We investigate how vision affects haptic performance when task-relevant visual cues are reduced or excluded. The task was to remember the spatial location of six landmarks that were explored by touch in a tactile map. Here, we use specially designed spectacles that simulate residual peripheral vision, tunnel vision, diffuse light perception, and total blindness. Results for target locations differed, suggesting additional effects from adjacent touch cues. These are discussed. Touch with full vision was most accurate, as expected. Peripheral and tunnel vision, which reduce visuo-spatial cues, differed in error pattern. Both were less accurate than full vision, and significantly more accurate than touch with diffuse light perception, and touch alone. The important finding was that touch with diffuse light perception, which excludes spatial cues, did not differ from touch without vision in performance accuracy, nor in location error pattern. The contrast between spatially relevant versus spatially irrelevant vision provides new, rather decisive, evidence against the hypothesis that vision affects haptic processing even if it does not add task-relevant information. The results support optimal integration theories, and suggest that spatial and non-spatial aspects of vision need explicit distinction in bimodal studies and theories of spatial integration.

  7. DARWIN Glass and DARWIN Crater Revisited. Multiple Impacts in the Australasian Strewn Field?

    NASA Astrophysics Data System (ADS)

    Meisel, T.; Biino, G. G.; Villa, I. M.; Chambers, J. E.; McHone, J. F.

    1995-09-01

    Darwin glass, an impact glass occurring in South West Tasmania, has been found at least since human beings reached Tasmania ca. 40 k.y. ago. Darwin glass, although in the proximity of the Australasian tektites strewn field, has never been counted as part of it. Darwin Crater was recognized about 30 years ago. Still, the existence of an impact structure in Tasmania has been neglected and does not show up in most compilations of known impact craters. Age determinations on Darwin Glass from the early 70's revealed a combined K-Ar and fission track age of 0.73 +/- 0.04 m.y. [1]. The most recent and most precise estimate for Australites and Indochinites yields 0.784 +/- 0.012 m.y. [2]. The two ages are indistinguishable from each other. This contemporaneity lead to the hypothesis that impact on Earth producing australites also formed Darwin Crater as a primary and/or secondary crater (Gentner et al., 1973). If one believes that all tektites of the Australian strewn field were produced by one impact in or near Indochina, then a special case is required to also form Darwin Crater, which is at least 5000 km away. Atmospheric breakup of a planetary body is a very unlikely possibility, because the distance travelled after breakup is too small to account for the dispersion. Double craters on Earth are always close to each other (e.g., Kara and Kara Ust). A more likely scenario could be an impact of an asteroidal body with an accompanying small moon (e.g., Ida and Gaspra). If one believes in multiple impacts for the formation of Muong Nong-type or layered tektites in the Australasian strewn field, then a collision of an asteroidal body with another body shortly before impact on Earth is required. In this case, an impact on Earth a large distance away (i.e., Tasmania) is realistic. To address the problem of crater recognition and possible simultaneous impact events, a new multidisciplinary investigation is currently underway. We intend to determine the age of three Darwin

  8. Vision

    NASA Technical Reports Server (NTRS)

    Taylor, J. H.

    1973-01-01

    Some data on human vision, important in present and projected space activities, are presented. Visual environment and performance and structure of the visual system are also considered. Visual perception during stress is included.

  9. OH Vision Test

    NASA Image and Video Library

    2014-06-03

    ISS040-E-006739 (3 June 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, uses the Optical Coherence Tomography (OCT) camera during an Ocular Health (OH) vision test in the Harmony node of the International Space Station. The OH experiment observes and seeks to understand vision changes during long-term space missions. NASA astronaut Steve Swanson (left), Expedition 40 commander, assists Gerst.

  10. Comparison of vision through surface modulated and spatial light modulated multifocal optics.

    PubMed

    Vinas, Maria; Dorronsoro, Carlos; Radhakrishnan, Aiswaryah; Benedi-Garcia, Clara; LaVilla, Edward Anthony; Schwiegerling, Jim; Marcos, Susana

    2017-04-01

    Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near.

  11. Grouping and emergent features in vision: toward a theory of basic Gestalts.

    PubMed

    Pomerantz, James R; Portillo, Mary C

    2011-10-01

    Gestalt phenomena are often so powerful that mere demonstrations can confirm their existence, but Gestalts have proven hard to define and measure. Here we outline a theory of basic Gestalts (TBG) that defines Gestalts as emergent features (EFs). The logic relies on discovering wholes that are more discriminable than are the parts from which they are built. These wholes contain EFs that can act as basic features in human vision. As context is added to a visual stimulus, a hierarchy of EFs appears. Starting with a single dot and adding a second yields the first two potential EFs: the proximity (distance) and orientation (angle) between the two dots. A third dot introduces two more potential EFs: symmetry and linearity; a fourth dot produces surroundedness. This hierarchy may extend to collinearity, parallelism, closure, and more. We use the magnitude of Configural Superiority Effects to measure the salience of EFs on a common scale, potentially letting us compare the strengths of various grouping principles. TBG appears promising, with our initial experiments establishing and quantifying at least three basic EFs in human vision.

  12. A Monocular Vision Sensor-Based Obstacle Detection Algorithm for Autonomous Robots.

    PubMed

    Lee, Tae-Jae; Yi, Dong-Hoon; Cho, Dong-Il Dan

    2016-03-01

    This paper presents a monocular vision sensor-based obstacle detection algorithm for autonomous robots. Each individual image pixel at the bottom region of interest is labeled as belonging either to an obstacle or the floor. While conventional methods depend on point tracking for geometric cues for obstacle detection, the proposed algorithm uses the inverse perspective mapping (IPM) method. This method is much more advantageous when the camera is not high off the floor, which makes point tracking near the floor difficult. Markov random field-based obstacle segmentation is then performed using the IPM results and a floor appearance model. Next, the shortest distance between the robot and the obstacle is calculated. The algorithm is tested by applying it to 70 datasets, 20 of which include nonobstacle images where considerable changes in floor appearance occur. The obstacle segmentation accuracies and the distance estimation error are quantitatively analyzed. For obstacle datasets, the segmentation precision and the average distance estimation error of the proposed method are 81.4% and 1.6 cm, respectively, whereas those for a conventional method are 57.5% and 9.9 cm, respectively. For nonobstacle datasets, the proposed method gives 0.0% false positive rates, while the conventional method gives 17.6%.

  13. A Monocular Vision Sensor-Based Obstacle Detection Algorithm for Autonomous Robots

    PubMed Central

    Lee, Tae-Jae; Yi, Dong-Hoon; Cho, Dong-Il “Dan”

    2016-01-01

    This paper presents a monocular vision sensor-based obstacle detection algorithm for autonomous robots. Each individual image pixel at the bottom region of interest is labeled as belonging either to an obstacle or the floor. While conventional methods depend on point tracking for geometric cues for obstacle detection, the proposed algorithm uses the inverse perspective mapping (IPM) method. This method is much more advantageous when the camera is not high off the floor, which makes point tracking near the floor difficult. Markov random field-based obstacle segmentation is then performed using the IPM results and a floor appearance model. Next, the shortest distance between the robot and the obstacle is calculated. The algorithm is tested by applying it to 70 datasets, 20 of which include nonobstacle images where considerable changes in floor appearance occur. The obstacle segmentation accuracies and the distance estimation error are quantitatively analyzed. For obstacle datasets, the segmentation precision and the average distance estimation error of the proposed method are 81.4% and 1.6 cm, respectively, whereas those for a conventional method are 57.5% and 9.9 cm, respectively. For nonobstacle datasets, the proposed method gives 0.0% false positive rates, while the conventional method gives 17.6%. PMID:26938540

  14. Escape Distance in Ground-Nesting Birds Differs with Individual Level of Camouflage.

    PubMed

    Wilson-Aggarwal, Jared K; Troscianko, Jolyon T; Stevens, Martin; Spottiswoode, Claire N

    2016-08-01

    Camouflage is one of the most widespread antipredator strategies in the animal kingdom, yet no animal can match its background perfectly in a complex environment. Therefore, selection should favor individuals that use information on how effective their camouflage is in their immediate habitat when responding to an approaching threat. In a field study of African ground-nesting birds (plovers, coursers, and nightjars), we tested the hypothesis that individuals adaptively modulate their escape behavior in relation to their degree of background matching. We used digital imaging and models of predator vision to quantify differences in color, luminance, and pattern between eggs and their background, as well as the plumage of incubating adult nightjars. We found that plovers and coursers showed greater escape distances when their eggs were a poorer pattern match to the background. Nightjars sit on their eggs until a potential threat is nearby, and, correspondingly, they showed greater escape distances when the pattern and color match of the incubating adult's plumage-rather than its eggs-was a poorer match to the background. Finally, escape distances were shorter in the middle of the day, suggesting that escape behavior is mediated by both camouflage and thermoregulation.

  15. Benefits of glass fibers in solar fiber optic lighting systems.

    PubMed

    Volotinen, Tarja T; Lingfors, David H S

    2013-09-20

    The transmission properties and coupling of solar light have been studied for glass core multimode fibers in order to verify their benefits for a solar fiber optic lighting system. The light transportation distance can be extended from 20 m with plastic fibers to over 100 m with the kind of glass fibers studied here. A high luminous flux, full visible spectrum, as well as an outstanding color rendering index (98) and correlated color temperature similar to the direct sun light outside have been obtained. Thus the outstanding quality of solar light transmitted through these fibers would improve the visibility of all kinds of objects compared to fluorescent and other artificial lighting. Annual relative lighting energy savings of 36% in Uppsala, Sweden, and 76% in Dubai were estimated in an office environment. The absolute savings can be doubled by using glass optical fibers, and are estimated to be in the order of 550 kWh/year in Sweden and 1160 kWh/year in Dubai for one system of only 0.159 m(2) total light collecting area. The savings are dependent on the fiber length, the daily usage time of the interior, the type of artificial lighting substituted, the system light output flux, and the available time of sunny weather at the geographic location.

  16. Virtual Vision

    NASA Astrophysics Data System (ADS)

    Terzopoulos, Demetri; Qureshi, Faisal Z.

    Computer vision and sensor networks researchers are increasingly motivated to investigate complex multi-camera sensing and control issues that arise in the automatic visual surveillance of extensive, highly populated public spaces such as airports and train stations. However, they often encounter serious impediments to deploying and experimenting with large-scale physical camera networks in such real-world environments. We propose an alternative approach called "Virtual Vision", which facilitates this type of research through the virtual reality simulation of populated urban spaces, camera sensor networks, and computer vision on commodity computers. We demonstrate the usefulness of our approach by developing two highly automated surveillance systems comprising passive and active pan/tilt/zoom cameras that are deployed in a virtual train station environment populated by autonomous, lifelike virtual pedestrians. The easily reconfigurable virtual cameras distributed in this environment generate synthetic video feeds that emulate those acquired by real surveillance cameras monitoring public spaces. The novel multi-camera control strategies that we describe enable the cameras to collaborate in persistently observing pedestrians of interest and in acquiring close-up videos of pedestrians in designated areas.

  17. Can Youthful Students be Encouraged to Self-repair Damaged Vision Using Elementary Mathematics and Physics Principles?

    NASA Astrophysics Data System (ADS)

    Ferreira, Nadja; McLeod, Roger

    2006-03-01

    Safe and easy self-repair of damaged vision in youth, detected from squinted eyes, motivated by simple applied math and physics, and over-stretched elastics. Parental permission and participation, with math skills of numerical cancellation, bring physics understanding to students. They recognize pupil diameter changes with light intensity. Ideas of focal surfaces and wavelength dependence can be achieved by burning paper with a magnifying glass, and dispersing light with a prism. Safeness of eye and head movements required are like those of the mother in applying makeup, or of a father in shaving. Easily defined, performed and monitored visual tasks can complete the repair(s).

  18. Watching Silica's Dance: Imaging the Structure and Dynamics of the Atomic (Re-) Arrangements in 2D Glass

    NASA Astrophysics Data System (ADS)

    Muller, David

    2014-03-01

    Even though glasses are almost ubiquitous--in our windows, on our iPhones, even on our faces--they are also mysterious. Because glasses are notoriously difficult to study, basic questions like: ``How are the atoms arranged? Where and how do glasses break?'' are still under contention. We use aberration corrected transmission electron microscopy (TEM) to image the atoms in a new two-dimensional phase of silica glass - freestanding it becomes the world's thinnest pane of glass at only 3-atoms thick, and take a unique look into these questions. Using atom-by-atom imaging and spectroscopy, we are able to reconstruct the full structure and bonding of this 2D glass and identify it as a bi-tetrahedral layer of SiO2. Our images also strikingly resemble Zachariasen's original cartoon models of glasses, drawn in 1932. As such, our work realizes an 80-year-old vision for easily understandable glassy systems and introduces promising methods to test theoretical predictions against experimental data. We image atoms in the disordered solid and track their motions in response to local strain. We directly obtain ring statistics and pair distribution functions that span short-, medium-, and long-range order, and test these against long-standing theoretical predictions of glass structure and dynamics. We use the electron beam to excite atomic rearrangements, producing surprisingly rich and beautiful videos of how a glass bends and breaks, as well as the exchange of atoms at a solid/liquid interface. Detailed analyses of these videos reveal a complex dance of elastic and plastic deformations, phase transitions, and their interplay. These examples illustrate the wide-ranging and fundamental materials physics that can now be studied at atomic-resolution via transmission electron microscopy of two-dimensional glasses. Work in collaboration with: S. Kurasch, U. Kaiser, R. Hovden, Q. Mao, J. Kotakoski, J. S. Alden, A. Shekhawat, A. A. Alemi, J. P. Sethna, P. L. McEuen, A.V. Krasheninnikov

  19. Current status of photoprotection by window glass, automobile glass, window films, and sunglasses.

    PubMed

    Almutawa, Fahad; Vandal, Robert; Wang, Steven Q; Lim, Henry W

    2013-04-01

    Ultraviolet radiation (UVR) has known adverse effects on the skin and eyes. Practitioners are becoming more aware of the importance of outdoor photoprotection. However, little attention is directed to the exposure of the skin and eyes to UVR through the window glass or sunglasses. The amount of ultraviolet transmission through glass depends mainly on the type of the glass. All types of commercial and automobile glass block the majority of ultraviolet-B; however, the degree of ultraviolet-A transmission depends on the type of glass. Laminated glass offers better UVA protection than tempered glass; new safety regulations for automobiles may result in increased use of laminated glass for side windows. Window films can be applied to glass to increase UVR protection. Sunglasses need to be compliant with one of the national standards; a wraparound style or side shields offer the best protection. Increased understanding by practitioners on the transmission of UVR through glass, window films, and sunglasses would allow them to better educate the public and to better manage photosensitive patients. © 2013 John Wiley & Sons A/S.

  20. [Comparison of the Pressure on the Larynx and Tongue Using McGRATH® MAC Video Laryngoscope--Direct Vision versus Indirect Vision].

    PubMed

    Tanaka, Yasutomo; Miyazaki, Yukiko; Kitakata, Hidenori; Shibuya, Hiromi; Okada, Toshiki

    2015-12-01

    Studies show that McGRATH® MAC (McG) is useful during direct laryngoscopy. However, no study has examined whether McG re- duces pressure on the upper airway tract We compared direct vision with indirect vision concerning pressure on the larynx and tongue. Twenty two anesthesiologists and 16 junior residents attempted direct laryngoscopy of airway management simulator using McG with direct vision and indirect vision. Pressure was measured using pressure measurement film. In anesthesiologists group, pressure on larynx was 14.8 ± 2.7 kgf · cm(-2) with direct vision and 12.7 ± 2.7 kgf · cm(-2) with indirect vision (P < 0.05). Pressure on the tongue was 8.8 ± 3.2 kgf cm(-2) with direct vision and 7.6 ± 2.8 kgf · cm(-2) with indirect vision (P = 0.18). In junior residents group, pressure on larynx was 19.0 ± 1.3 kgf · cm(-2) with direct vision and 14.1 ± 3.1 kgf · cm(-2) with indirect vision (P < 0.05). Pressure on the tongue was 15.4 ± 3.6 kgf · cm(-2) with direct vision and 11.2 ± 4.7 kgf · cm(-2) with indirect vision (P < 0.05). McG with indirect vision can reduce pressure on the upper airway tract.

  1. Compositional Models of Glass/Melt Properties and their Use for Glass Formulation

    DOE PAGES

    Vienna, John D.; USA, Richland Washington

    2014-12-18

    Nuclear waste glasses must simultaneously meet a number of criteria related to their processability, product quality, and cost factors. The properties that must be controlled in glass formulation and waste vitrification plant operation tend to vary smoothly with composition allowing for glass property-composition models to be developed and used. Models have been fit to the key glass properties. The properties are transformed so that simple functions of composition (e.g., linear, polynomial, or component ratios) can be used as model forms. The model forms are fit to experimental data designed statistically to efficiently cover the composition space of interest. Examples ofmore » these models are found in literature. The glass property-composition models, their uncertainty definitions, property constraints, and optimality criteria are combined to formulate optimal glass compositions, control composition in vitrification plants, and to qualify waste glasses for disposal. An overview of current glass property-composition modeling techniques is summarized in this paper along with an example of how those models are applied to glass formulation and product qualification at the planned Hanford high-level waste vitrification plant.« less

  2. Vehicle autonomous localization in local area of coal mine tunnel based on vision sensors and ultrasonic sensors

    PubMed Central

    Yang, Wei; You, Kaiming; Li, Wei; Kim, Young-il

    2017-01-01

    This paper presents a vehicle autonomous localization method in local area of coal mine tunnel based on vision sensors and ultrasonic sensors. Barcode tags are deployed in pairs on both sides of the tunnel walls at certain intervals as artificial landmarks. The barcode coding is designed based on UPC-A code. The global coordinates of the upper left inner corner point of the feature frame of each barcode tag deployed in the tunnel are uniquely represented by the barcode. Two on-board vision sensors are used to recognize each pair of barcode tags on both sides of the tunnel walls. The distance between the upper left inner corner point of the feature frame of each barcode tag and the vehicle center point can be determined by using a visual distance projection model. The on-board ultrasonic sensors are used to measure the distance from the vehicle center point to the left side of the tunnel walls. Once the spatial geometric relationship between the barcode tags and the vehicle center point is established, the 3D coordinates of the vehicle center point in the tunnel’s global coordinate system can be calculated. Experiments on a straight corridor and an underground tunnel have shown that the proposed vehicle autonomous localization method is not only able to quickly recognize the barcode tags affixed to the tunnel walls, but also has relatively small average localization errors in the vehicle center point’s plane and vertical coordinates to meet autonomous unmanned vehicle positioning requirements in local area of coal mine tunnel. PMID:28141829

  3. Vehicle autonomous localization in local area of coal mine tunnel based on vision sensors and ultrasonic sensors.

    PubMed

    Xu, Zirui; Yang, Wei; You, Kaiming; Li, Wei; Kim, Young-Il

    2017-01-01

    This paper presents a vehicle autonomous localization method in local area of coal mine tunnel based on vision sensors and ultrasonic sensors. Barcode tags are deployed in pairs on both sides of the tunnel walls at certain intervals as artificial landmarks. The barcode coding is designed based on UPC-A code. The global coordinates of the upper left inner corner point of the feature frame of each barcode tag deployed in the tunnel are uniquely represented by the barcode. Two on-board vision sensors are used to recognize each pair of barcode tags on both sides of the tunnel walls. The distance between the upper left inner corner point of the feature frame of each barcode tag and the vehicle center point can be determined by using a visual distance projection model. The on-board ultrasonic sensors are used to measure the distance from the vehicle center point to the left side of the tunnel walls. Once the spatial geometric relationship between the barcode tags and the vehicle center point is established, the 3D coordinates of the vehicle center point in the tunnel's global coordinate system can be calculated. Experiments on a straight corridor and an underground tunnel have shown that the proposed vehicle autonomous localization method is not only able to quickly recognize the barcode tags affixed to the tunnel walls, but also has relatively small average localization errors in the vehicle center point's plane and vertical coordinates to meet autonomous unmanned vehicle positioning requirements in local area of coal mine tunnel.

  4. Color Vision in Aniridia.

    PubMed

    Pedersen, Hilde R; Hagen, Lene A; Landsend, Erlend C S; Gilson, Stuart J; Utheim, Øygunn A; Utheim, Tor P; Neitz, Maureen; Baraas, Rigmor C

    2018-04-01

    To assess color vision and its association with retinal structure in persons with congenital aniridia. We included 36 persons with congenital aniridia (10-66 years), and 52 healthy, normal trichromatic controls (10-74 years) in the study. Color vision was assessed with Hardy-Rand-Rittler (HRR) pseudo-isochromatic plates (4th ed., 2002); Cambridge Color Test and a low-vision version of the Color Assessment and Diagnosis test (CAD-LV). Cone-opsin genes were analyzed to confirm normal versus congenital color vision deficiencies. Visual acuity and ocular media opacities were assessed. The central 30° of both eyes were imaged with the Heidelberg Spectralis OCT2 to grade the severity of foveal hypoplasia (FH, normal to complete: 0-4). Five participants with aniridia had cone opsin genes conferring deutan color vision deficiency and were excluded from further analysis. Of the 31 with aniridia and normal opsin genes, 11 made two or more red-green (RG) errors on HRR, four of whom also made yellow-blue (YB) errors; one made YB errors only. A total of 19 participants had higher CAD-LV RG thresholds, of which eight also had higher CAD-LV YB thresholds, than normal controls. In aniridia, the thresholds were higher along the RG than the YB axis, and those with a complete FH had significantly higher RG thresholds than those with mild FH (P = 0.038). Additional increase in YB threshold was associated with secondary ocular pathology. Arrested foveal formation and associated alterations in retinal processing are likely to be the primary reason for impaired red-green color vision in aniridia.

  5. Review: Pressure-Induced Densification of Oxide Glasses at the Glass Transition

    NASA Astrophysics Data System (ADS)

    Kapoor, Saurabh; Wondraczek, Lothar; Smedskjaer, Morten M.

    2017-02-01

    Densification of oxide glasses at the glass transition offers a novel route to develop bulk glasses with tailored properties for emerging applications. Such densification can be achieved in the technologically relevant pressure regime of up to 1GPa. However, the present understanding of the composition-structure-property relationships governing these glasses is limited, with key questions, e.g., related to densification mechanism, remaining largely unanswered. Recent advances in structural characterization tools and high-pressure apparatuses have prompted new research efforts. Here, we review this recent progress and the insights gained in the understanding of the influence of isostatic compression at elevated temperature (so-called hot compression) on the composition-structure-property relationships of oxide glasses. We focus on compression at temperatures at or around the glass transition temperature (Tg), with relevant comparisons made to glasses prepared by pressure quenching and cold compression. We show that permanent densification at 1 GPa sets-in at temperatures above 0.7Tg and the degree of densification increases with increasing compression temperature and time, until attaining an approximately constant value for temperatures above Tg. For glasses compressed at the same temperature/pressure conditions, we demonstrate direct relations between the degree of volume densification and the pressure-induced change in micro-mechanical properties such as hardness, elastic moduli, and extent of the indentation size effect across a variety of glass families. Furthermore, we summarize the results on relaxation behavior of hot compressed glasses. All the pressure-induced changes in the structure and properties exhibit strong composition dependence. The experimental results highlight new opportunities for future investigation and identify research challenges that need to be overcome to advance the field.

  6. Prevalence and causes of low vision and blindness in an elderly population in Nepal: the Bhaktapur retina study.

    PubMed

    Thapa, Raba; Bajimaya, Sanyam; Paudyal, Govinda; Khanal, Shankar; Tan, Stevie; Thapa, Suman S; van Rens, G H M B

    2018-02-13

    This study aims to explore the prevalence and causes of low vision and blindness focused on retinal disease in a population above 60 years in Nepal. Two thousand one hundred subjects were enrolled in a population-based cross-sectional study. History, presenting and best corrected visual acuity after subjective refraction, anterior and posterior segment examinations was obtained in detail. Among the total subjects, 1860 (88.57%) had complete information. Age varies from 60 to 95 (mean age: 69.64 ± 7.31) years. Low vision and blindness in both eyes at presentation was found in 984 (52.90%, 95% confidence interval (CI): 50.60-55.19) and 36 (1.94%, 95% CI: 1.35-2.66) subjects respectively. After best correction, bilateral low vision and blindness was found in 426 (22.92%, 95% CI: 21.01-24.88), and 30 (1.61%, 95% CI: 0.10-2.30) subjects respectively. As compared to 60-69 years old, risk of visual impairment was four times higher (95% CI:3.26-5.58) in the 70-79 year olds and 14 times higher (95% CI: 9.72-19.73) in the age group 80 years and above. Major causes of bilateral low vision were cataract (68.07%), followed by retinal disorders (28.64%), and for blindness; retinal disorders (46.66%), followed by cataract (43.33%). Illiteracy was significantly associated with visual impairment. Among the elderly population, prevalence of visual impairment was high. Refractive error, cataract and retinal disorders were the major cause of low vision. Screening the population at the age 60 years and above, focus