DOE Office of Scientific and Technical Information (OSTI.GOV)
Palazzi, Mauro; Orlandi, Ester; Bossi, Paolo
2009-07-01
Purpose: To report the outcome of a consecutive series of patients with nonmetastatic nasopharyngeal carcinoma (NPC), focusing on the impact of treatment-related factors. Methods and Materials: Between 2000 and 2006, 87 patients with NPC were treated with either conventional (two- or three-dimensional) radiotherapy (RT) or with intensity-modulated RT (IMRT). Of these patients, 81 (93%) received either concomitant CHT (24%) or both induction and concomitant chemotherapy (CHT) (69%). Stage was III in 36% and IV in 39% of patients. Outcomes in this study population were compared with those in the previous series of 171 patients treated during 1990 to 1999. Results:more » With a median follow-up of 46 months, actuarial rates at 3 years were the following: local control, 96%; local-regional control, 93%; distant control (DC), 90%; disease-free survival (DFS), 82%; overall survival, 90%. In Stage III to IV patients, distant control at 3 years was 56% in patients treated with concomitant CHT only and 92% in patients treated with both induction and concomitant CHT (p = 0.014). At multivariate analysis, histology, N-stage, RT technique, and total RT dose had the strongest independent impact on DFS (p < 0.05). Induction CHT had a borderline effect on DC (p = 0.07). Most dosimetric statistics were improved in the group of patients treated with IMRT compared with conventional 3D technique. All outcome endpoints were substantially better in the study population compared with those in the previous series. Conclusions: Outcome of NPC has further improved in the study period compared with the previous decade, with a significant effect of RT technique optimization. The impact of induction CHT remains to be demonstrated in controlled trials.« less
Endo, Hisahito; Saito, Takuro; Kenjo, Akira; Hoshino, Mika; Terashima, Masanori; Sato, Tetsu; Anazawa, Takayuki; Kimura, Takashi; Tsuchiya, Takao; Irisawa, Atsushi; Ohira, Hiromasa; Hikichi, Takuto; Takagi, Tadayuki; Gotoh, Mitsukazu
2012-07-01
To determine the feasibility, safety and histological change of preoperative endoscopic ultrasound-guided fine-needle injection (PEU-FNI) of immature DCs (iDCs) with OK-432 in pancreatic cancer patients. Nine patients enrolled in the trial (DC group) and were compared with 15 patients operated on without iDC injection (non-DC group). Adverse events of PEU-FNI and postoperative complications were evaluated according to CTC-AE ver.3.0 and the Clavien-Dindo classification/ISGPF definition, respectively. Histological changes within the tumor and lymph nodes were evaluated by immunohistochemical examination of infiltrating inflammatory cells (CD4+, CD8+, Foxp3+ and CD83+). There were no severe toxicities following PEU-FNI, except for one transient grade 3 fever, and there were no significant differences in the incidence of postoperative complications between the two groups. Colliquative necrosis and diffusely scattered TUNEL-positive cells were observed at the injection sites. CD83+ cells significantly accumulated in the regional lymph nodes of the DC group as well as Foxp3+ cells in the regional and distant lymph nodes. The two DC group patients, one of which was stage IV with distant lymph node metastasis, survived more than 5 years without requiring adjuvant theraphy. PEU-FNI was feasible and safe, and further study needs to confirm and enhance antitumor responses.
Leone, Dario Armando; Peschel, Andrea; Brown, Markus; Schachner, Helga; Ball, Miriam J; Gyuraszova, Marianna; Salzer-Muhar, Ulrike; Fukuda, Minoru; Vizzardelli, Caterina; Bohle, Barbara; Rees, Andrew J; Kain, Renate
2017-07-15
The lysosome-associated membrane protein (LAMP) family includes the dendritic cell endocytic receptors DC-LAMP and CD68, as well as LAMP-1 and LAMP-2. In this study we identify LAMP-1 (CD107a) and LAMP-2 (CD107b) on the surface of human monocyte-derived dendritic cells (MoDC) and show only LAMP-2 is internalized after ligation by specific Abs, including H4B4, and traffics rapidly but transiently to the MHC class II loading compartment, as does Ag conjugated to H4B4. However, pulsing MoDC with conjugates of primary (keyhole limpet hemocyanin; KLH) and recall (Bet v 1) Ags (H4B4*KLH and H4B4*Bet v 1) induced significantly less CD4 cell proliferation than pulsing with native Ag or Ag conjugated to control mAb (ISO*KLH and ISO*Bet v 1). In H4B4*KLH-pulsed MoDC, the duration of KLH residence in MHC class II loading compartments was significantly reduced, as were surface HLA-DR and DR-bound KLH-derived peptides. Paradoxically, MoDC pulsed with H4B4*KLH, but not the other KLH preparations, induced robust proliferation of CD4 cells separated from them by a transwell membrane, indicating factors in the supernatant were responsible. Furthermore, extracellular vesicles from supernatants of H4B4*KLH-pulsed MoDC contained significantly more HLA-DR and KLH than those purified from control MoDC, and KLH was concentrated specifically in exosomes that were a uniquely effective source of Ag in standard T cell proliferation assays. In summary, we identify LAMP-2 as an endocytic receptor on human MoDC that routes cargo into unusual Ag processing pathways, which reduces surface expression of Ag-derived peptides while selectively enriching Ag within immunogenic exosomes. This novel pathway has implications for the initiation of immune responses both locally and at distant sites. Copyright © 2017 by The American Association of Immunologists, Inc.
Lambert, Henrik; Hitziger, Niclas; Dellacasa, Isabel; Svensson, Mattias; Barragan, Antonio
2006-10-01
The processes leading to systemic dissemination of the obligate intracellular parasite Toxoplasma gondii remain unelucidated. In vitro studies on human and murine dendritic cells (DC) revealed that active invasion of DC by Toxoplasma induces a state of hypermotility in DC, enabling transmigration of infected DC across endothelial cell monolayers in the absence of chemotactic stimuli. Infected DC exhibited upregulation of maturation markers and co-stimulatory molecules. While modulation of cell adhesion molecules CD11/CD18 was similar for Toxoplasma-infected DC and lipopolysaccharide (LPS)-matured DC, Toxoplasma-infected DC did not exhibit upregulation of CD54/ICAM-1. Induction of host cell migration in vitro required live intracellular parasite(s) and was inhibited by uncoupling the Gi-protein signalling pathway with pertussis toxin, but did not depend on CCR5, CCR7 or Toll/interleukin-1 receptor signalling. When migration of Toxoplasma-infected DC was compared with migration of LPS-stimulated DC in vivo, similar or higher numbers of Toxoplasma-infected DC reached the mesenteric lymph nodes and spleen respectively. Adoptive transfer of Toxoplasma-infected DC resulted in more rapid dissemination of parasites to distant organs and in exacerbation of infection compared with inoculation with free parasites. Altogether, these findings show that Toxoplasma is able to subvert the regulation of host cell motility and likely exploits the host's natural pathways of cellular migration for parasite dissemination.
Rödel, Franz; Steinhäuser, Kerstin; Kreis, Nina-Naomi; Friemel, Alexandra; Martin, Daniel; Wieland, Ulrike; Rave-Fränk, Margret; Balermpas, Panagiotis; Fokas, Emmanouil; Louwen, Frank; Rödel, Claus; Yuan, Juping
2018-02-01
RBP-J interacting and tubulin-associated protein (RITA) has been identified as a negative regulator of the Notch signalling pathway and its deregulation is involved in the pathogenesis of several tumour entities. RITA's impact on the response of anal squamous cell carcinoma (SCC) to anticancer treatment, however, remains elusive. In our retrospective study immunohistochemical evaluation of RITA was performed on 140 pre-treatment specimens and was correlated with clinical and histopathologic characteristics and clinical endpoints cumulative incidence of local control (LC), distant recurrence (DC), disease-free survival (DFS) and overall survival (OS). We observed significant inverse correlations between RITA expression and tumour grading, the levels of HPV-16 virus DNA load, CD8 (+) tumour infiltrating lymphocytes and programmed death protein (PD-1) immunostaining. In univariate analyses, elevated levels of RITA expression were predictive for decreased local control (p = 0.001), decreased distant control (p = 0.040), decreased disease free survival (p = 0.001) and overall survival (p < 0.0001), whereas in multivariate analyses RITA expression remained significant for decreased local control (p = 0.009), disease free survival (p = 0.032) and overall survival (p = 0.012). These data indicate that elevated levels of pretreatment RITA expression are correlated with unfavourable clinical outcome in anal carcinoma treated with concomitant chemoradiotherapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Differential Impact of Whole-Brain Radiotherapy Added to Radiosurgery for Brain Metastases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kong, Doo-Sik; Lee, Jung-Il, E-mail: jilee@skku.ed; Im, Yong-Seok
2010-10-01
Purpose: The authors investigated whether the addition of whole-brain radiotherapy (WBRT) to stereotactic radiosurgery (SRS) provided any therapeutic benefit according to recursive partitioning analysis (RPA) class. Methods and Materials: Two hundred forty-five patients with 1 to 10 metastases who underwent SRS between January 2002 and December 2007 were included in the study. Of those, 168 patients were treated with SRS alone and 77 patients received SRS followed by WBRT. Actuarial curves were estimated using the Kaplan-Meier method regarding overall survival (OS), distant brain control (DC), and local brain control (LC) stratified by RPA class. Analyses for known prognostic variables weremore » performed using the Cox proportional hazards model. Results: Univariate and multivariate analysis revealed that control of the primary tumor, small number of brain metastases, Karnofsky performance scale (KPS) > 70, and initial treatment modalities were significant predictors for survival. For RPA class 1, SRS plus WBRT was associated with a longer survival time compared with SRS alone (854 days vs. 426 days, p = 0.042). The SRS plus WBRT group also showed better LC rate than did the SRS-alone group (p = 0.021), although they did not show a better DC rate (p = 0.079). By contrast, for RPA class 2 or 3, no significant difference in OS, LC, or DC was found between the two groups. Conclusions: These results suggest that RPA classification should determine whether or not WBRT is added to SRS. WBRT may be recommended to be added to SRS for patients in whom long-term survival is expected on the basis of RPA classification.« less
Wang, Pengyun; Li, Rui; Yu, Jing; Huang, Zirui; Yan, Zhixiong; Zhao, Ke; Li, Juan
2017-01-01
Few studies to date have investigated the background network in the cognitive state relying on executive function in mild cognitive impairment (MCI) patients. Using the index of degree of centrality (DC), we explored distant synchronization of background network in MCI during a hybrid delayed-match-to-sample task (DMST), which mainly relies on the working memory component of executive function. We observed significant interactions between group and cognitive state in the bilateral posterior cingulate cortex (PCC) and the ventral subregion of precuneus. For normal control (NC) group, the long distance functional connectivity (FC) of the PCC/precuneus with the other regions of the brain was higher in rest state than that working memory state. For MCI patients, however, this pattern altered. There was no significant difference between rest and working memory state. The similar pattern was observed in the other cluster located in the right angular gyrus. To examine whether abnormal DC in PCC/precuneus and angular gyrus partially resulted from the deficit of FC between these regions and the other parts in the whole brain, we conducted a seed-based correlation analysis with these regions as seeds. The results indicated that the FC between bilateral PCC/precuneus and the right inferior parietal lobule (IPL) increased from rest to working memory state for NC participants. For MCI patients, however, there was no significant change between rest and working memory state. The similar pattern was observed for the FC between right angular gyrus and right anterior insula. However, there was no difference between MCI and NC groups in global efficiency and modularity. It may indicate a lack of efficient reorganization from rest state to a working memory state in the brain network of MCI patients. The present study demonstrates the altered distant synchronization of background network in MCI during a task relying on executive function. The results provide a new perspective regarding the neural mechanisms of executive function deficits in MCI patients, and extend our understanding of brain patterns in task-evoked cognitive states.
Decoy receptor 3 is a prognostic factor in renal cell cancer.
Macher-Goeppinger, Stephan; Aulmann, Sebastian; Wagener, Nina; Funke, Benjamin; Tagscherer, Katrin E; Haferkamp, Axel; Hohenfellner, Markus; Kim, Sunghee; Autschbach, Frank; Schirmacher, Peter; Roth, Wilfried
2008-10-01
Decoy receptor 3 (DcR3) is a soluble protein that binds to and inactivates the death ligand CD95L. Here, we studied a possible association between DcR3 expression and prognosis in patients with renal cell carcinomas (RCCs). A tissue microarray containing RCC tumor tissue samples and corresponding normal tissue samples was generated. Decoy receptor 3 expression in tumors of 560 patients was examined by immunohistochemistry. The effect of DcR3 expression on disease-specific survival and progression-free survival was assessed using univariate analysis and multivariate Cox regression analysis. Decoy receptor 3 serum levels were determined by ELISA. High DcR3 expression was associated with high-grade (P = .005) and high-stage (P = .048) RCCs. The incidence of distant metastasis (P = .03) and lymph node metastasis (P = .002) was significantly higher in the group with high DcR3 expression. Decoy receptor 3 expression correlated negatively with disease-specific survival (P < .001) and progression-free survival (P < .001) in univariate analyses. A multivariate Cox regression analysis retained DcR3 expression as an independent prognostic factor that outperformed the Karnofsky performance status. In patients with high-stage RCCs expressing DcR3, the 2-year survival probability was 25%, whereas in patients with DcR3-negative tumors, the survival probability was 65% (P < .001). Moreover, DcR3 serum levels were significantly higher in patients with high-stage localized disease (P = .007) and metastatic disease (P = .001). DcR3 expression is an independent prognostic factor of RCC progression and mortality. Therefore, the assessment of DcR3 expression levels offers valuable prognostic information that could be used to select patients for adjuvant therapy studies.
Ribassin-Majed, Laureen; Marguet, Sophie; Lee, Anne W.M.; Ng, Wai Tong; Ma, Jun; Chan, Anthony T.C.; Huang, Pei-Yu; Zhu, Guopei; Chua, Daniel T.T.; Chen, Yong; Mai, Hai-Qiang; Kwong, Dora L.W.; Cheah, Shie-Lee; Moon, James; Tung, Yuk; Chi, Kwan-Hwa; Fountzilas, George; Bourhis, Jean; Pignon, Jean Pierre
2017-01-01
Purpose The role of adjuvant chemotherapy (AC) or induction chemotherapy (IC) in the treatment of locally advanced nasopharyngeal carcinoma is controversial. The individual patient data from the Meta-Analysis of Chemotherapy in Nasopharynx Carcinoma database were used to compare all available treatments. Methods All randomized trials of radiotherapy (RT) with or without chemotherapy in nonmetastatic nasopharyngeal carcinoma were considered. Overall, 20 trials and 5,144 patients were included. Treatments were grouped into seven categories: RT alone (RT), IC followed by RT (IC-RT), RT followed by AC (RT-AC), IC followed by RT followed by AC (IC-RT-AC), concomitant chemoradiotherapy (CRT), IC followed by CRT (IC-CRT), and CRT followed by AC (CRT-AC). P-score was used to rank the treatments. Fixed- and random-effects frequentist network meta-analysis models were applied. Results The three treatments with the highest probability of benefit on overall survival (OS) were CRT-AC, followed by CRT and IC-CRT, with respective hazard ratios (HRs [95% CIs]) compared with RT alone of 0.65 (0.56 to 0.75), 0.77 (0.64 to 0.92), and 0.81 (0.63 to 1.04). HRs (95% CIs) of CRT-AC compared with CRT for OS, progression-free survival (PFS), locoregional control, and distant control (DC) were, respectively, 0.85 (0.68 to 1.05), 0.81 (0.66 to 0.98), 0.70 (0.48 to 1.02), and 0.87 (0.61 to 1.25). IC-CRT ranked second for PFS and the best for DC. CRT never ranked first. HRs of CRT compared with IC-CRT for OS, PFS, locoregional control, and DC were, respectively, 0.95 (0.72 to 1.25), 1.13 (0.88 to 1.46), 1.05 (0.70 to 1.59), and 1.55 (0.94 to 2.56). Regimens with more chemotherapy were associated with increased risk of acute toxicity. Conclusion The addition of AC to CRT achieved the highest survival benefit and consistent improvement for all end points. The addition of IC to CRT achieved the highest effect on DC. PMID:27918720
Weissinger, Daniel; Tagscherer, Katrin E; Macher-Göppinger, Stephan; Haferkamp, Axel; Wagener, Nina; Roth, Wilfried
2013-10-10
Overexpression of Decoy Receptor 3 (DcR3), a soluble member of the tumor necrosis factor receptor superfamily, is a common event in several types of cancer. In renal cell carcinoma (RCC), DcR3 overexpression is associated with lymph node and distant metastasis as well as a poor prognosis. However, the functional role and regulation of DcR3 expression in RCC is so far unknown. Modulation of DcR3 expression by siRNA and ectopic gene expression, respectively, was performed in ACHN and 769-P RCC cell lines. Functional effects of a modulated DcR3 expression were analyzed with regard to migration, invasion, adhesion, clonogenicity, and proliferation. Furthermore, quantitative RT-PCR and immunoblot analyses were performed to evaluate the expression of downstream mediators of DcR3. In further experiments, luciferase assays, quantitative RT-PCR and immunoblot analyses were applied to study the regulation of DcR3 expression in RCC. Additionally, an ex vivo tissue slice culture technique combined with immunohistochemistry was used to study the regulation of DcR3 expression in human RCC specimens. Here, we show that DcR3 promotes adhesion, migration and invasiveness of RCC cells. The DcR3-dependent increase in cellular invasiveness is accompanied with an up-regulation of integrin alpha 4, matrixmetalloproteinase 7 and urokinase plasminogen activator (uPA). Further, we identified a signaling pathway regulating DcR3 expression in RCC. Using in vitro experiments as well as an ex vivo RCC tissue slice culture model, we demonstrate that expression of DcR3 is regulated in a PI3K/AKT-dependent manner involving the transcription factor nuclear factor of activated T-cells (NFAT). Taken together, our results identify DcR3 as a key driver of tumor cell dissemination and suggest DcR3 as a promising target for rational therapy of RCC.
Gouw, Zeno A R; Paul de Boer, Jan; Navran, Arash; van den Brekel, Michiel W M; Sonke, Jan-Jakob; Al-Mamgani, Abrahim
2018-03-01
To study the prognostic value of abnormalities in baseline complete blood count in patients with oropharyngeal cancer (OPC) treated with (chemo) radiation. The prognostic value of baseline complete blood count on outcome in 234 patients with OPC treated between 2010 and 2015 was examined in multivariate analysis together with other conventional prognostic variables including HPV-status, tumor stage, tumor and nodal size. The 3-year overall survival (OS), disease-free survival (DFS), locoregional control (LRC), and distant control (DC) of the whole group were 74%, 64%, 79%, and 88%, respectively. Leukocytosis and HPV-status were the only significant prognosticators for OS and DFS at the multivariate analysis. Patients without leukocytosis had a significantly better DC compared to those with leukocytosis (92% and 70%, respectively, p < 0.001). Patients with HPV-negative OPC had significantly worse LRC compared to HPV-positive patients (67% and 90%, respectively, p < 0.001). The 3-year OS in HPV-positive group with leukocytosis compared to those without leukocytosis were 69% and 95%, respectively (p < 0.001). The figures for HPV-negative patients were 41% vs. 61%, respectively (p = 0.010). This is the first study to date reporting the independent impact of leukocytosis and HPV-status on outcome of patients with OPC. The poor outcome of patients with leukocytosis is mainly caused by the worse DC. The significant impact of leukocytosis on outcome was even more pronounced in HPV-positive patients. These biomarkers could help identifying patients with poor prognosis at baseline requiring intensification of local and/or systemic treatment while treatment de-intensification might be offered to the low-risk group. Copyright © 2018 Elsevier Ltd. All rights reserved.
Role of Adjuvant Chemoradiation Therapy in Adenocarcinomas of the Ampulla of Vater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krishnan, Sunil; Rana, Vishal; Evans, Douglas B.
2008-03-01
Purpose: The role of adjuvant chemoradiation therapy (CRT) in the treatment of ampullary cancers remains undefined. We retrospectively compared treatment outcomes in patients treated with pancreaticoduodenectomy alone versus those who received additional adjuvant CRT. Methods and Materials: Between May 1990 and January 2006, 54 of 96 patients with ampullary adenocarcinoma who underwent potentially curative pancreaticoduodenectomy also received adjuvant CRT. The median preoperative radiation dose was 45 Gy (range, 30-50.4 Gy) and median postoperative dose was 50.4 Gy (range, 45-55.8 Gy). Concurrent chemotherapy included primarily 5-fluorouracil (52%) and capecitabine (43%). Median follow-up was 31 months. Univariate and multivariate statistical methodologies weremore » used to determine significant prognostic factors for local control (LC), distant control (DC), and overall survival (OS). Results: Actuarial 5-year LC, DC, and OS were 77%, 69%, and 64%, respectively. On univariate analysis, age, gender, race/ethnicity, tumor grade, use of adjuvant treatment, and sequencing of adjuvant therapy were not significantly associated with LC, DC, or OS. However, on univariate analysis, T3/T4 tumor stage was prognostic for poorer LC and OS (p = 0.02 and p < 0.001, respectively); node-positive disease was prognostic for poorer LC (p = 0.03). On multivariate analysis, T3/T4 tumor stage was independently prognostic for decreased OS (p = 0.002). Among these patients (n = 34), those who received adjuvant CRT had a trend toward improved OS (median, 35.2 vs. 16.5 months; p = 0.06). Conclusions: Ampullary cancers have a distinctly better treatment outcome than pancreatic adenocarcinomas. Higher primary tumor stage (T3/T4), an independent adverse risk factor for poorer treatment outcomes, may warrant the addition of adjuvant CRT to pancreaticoduodenectomy.« less
Weeks, William B; Goertz, Christine M; Meeker, William C; Marchiori, Dennis M
2015-10-01
The purpose of this study was to determine whether general perceptions of doctors of chiropractic (DCs) varied according to likeliness to use chiropractic care, whether particular demographic characteristics were associated with chiropractic care use, and whether perception of DCs varied according to the per-capita supply of DCs in local health care markets. We performed a secondary analysis of results from a 26-item nationally representative survey of 5422 members of The Gallup Panel that was conducted in the spring of 2015 (response rate, 29%) that sought to elicit the perceptions and use of DCs by US adults. We compared survey responses across: (1) respondents who had different likelihoods to use DCs for treatment of neck or back pain and (2) respondents who had different experiences using DCs. We linked respondents' zip codes to hospital referral regions for which we had the per-capita supply of DCs. Using the χ(2) test, we examined relationships between likeliness to use a DC, experience using a DC, respondent demographic variables, perceptions of DCs, and the per-capita supply of DCs in the local health care market. Most (61.4%) respondents believed that chiropractic care was effective at treating neck and back pain, 52.6% thought DCs were trustworthy, and 24.2% thought chiropractic care was dangerous; however, as respondents' likelihood to use a DC increased, perceptions of effectiveness and trustworthiness increased, and perceptions of danger decreased. Of all 5422 survey respondents, 744 or 13.7% indicated that they had seen a DC within the last 12 months. As one moved from distant to more recent experience using a DC, respondents were more likely to be female, married, white, and employed; those who had a distant history of using a DC were older and more likely to be retired than the other groups. A higher per-capita supply of DCs was associated with higher utilization rates and showed a more favorable regard for DCs. US adults often use chiropractic care, generally regard DCs favorably, and largely perceive that chiropractic care is safe. Where there is a higher per-capita supply of DCs in the local health care market, utilization and positive perceptions of chiropractic are higher. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
ICRF antenna-plasma interactions and its influence on W sputtering in ASDEX upgrade
NASA Astrophysics Data System (ADS)
ASDEX Upgrade Team Bobkov, Vl.; Braun, F.; Colas, L.; Dux, R.; Faugel, H.; Giannone, L.; Herrmann, A.; Kallenbach, A.; Müller, H. W.; Neu, R.; Noterdaeme, J.-M.; Pütterich, Th.; Siegl, G.; Wolfrum, E.
2011-08-01
Analysis of the W concentration during ICRF over AUG experimental campaigns confirms the critical role of W antenna limiters for the W content in plasma, though other structures connected to antennas along magnetic field lines cannot be neglected as W sources.Abrupt changes of spectroscopically measured W sputtering patterns are observed which correlate with step-wise changes of connection lengths at antenna limiters. Analysis of discharges with the reversed direction of toroidal magnetic field shows less W release compared to identical discharges with the normal direction. The lower W release is accompanied by lower intensity of fluctuations of reflected ICRF power in the 1-60 kHz range. The observations suggest that local magnetic geometry and density convection at the antennas are at least as important for the W sputtering as the distribution of RF near-fields at the antenna.Measurements of DC currents flowing through the antenna limiters show that the limiters at the active antenna collect predominantly negative DC currents whereas those distant from the active antenna collect predominantly positive DC currents. The latter decrease and become more negative when the intensity of the RF pickup measured at the limiters increases. The mutual compensation between the positive and negative currents can lead to lower values of the DC current than those expected from simplified theoretical models of the RF/DC circuit.
ICRF antenna-plasma interactions and its influence on W sputtering in ASDEX upgrade
NASA Astrophysics Data System (ADS)
Bobkov, Vl.; Braun, F.; Colas, L.; Dux, R.; Faugel, H.; Giannone, L.; Herrmann, A.; Kallenbach, A.; Müller, H. W.; Neu, R.; Noterdaeme, J.-M.; Pütterich, Th.; Siegl, G.; Wolfrum, E.; ASDEX Upgrade Team
2011-08-01
Analysis of the W concentration during ICRF over AUG experimental campaigns confirms the critical role of W antenna limiters for the W content in plasma, though other structures connected to antennas along magnetic field lines cannot be neglected as W sources. Abrupt changes of spectroscopically measured W sputtering patterns are observed which correlate with step-wise changes of connection lengths at antenna limiters. Analysis of discharges with the reversed direction of toroidal magnetic field shows less W release compared to identical discharges with the normal direction. The lower W release is accompanied by lower intensity of fluctuations of reflected ICRF power in the 1-60 kHz range. The observations suggest that local magnetic geometry and density convection at the antennas are at least as important for the W sputtering as the distribution of RF near-fields at the antenna. Measurements of DC currents flowing through the antenna limiters show that the limiters at the active antenna collect predominantly negative DC currents whereas those distant from the active antenna collect predominantly positive DC currents. The latter decrease and become more negative when the intensity of the RF pickup measured at the limiters increases. The mutual compensation between the positive and negative currents can lead to lower values of the DC current than those expected from simplified theoretical models of the RF/DC circuit.
Chandra Finds Most Distant X-ray Galaxy Cluster
NASA Astrophysics Data System (ADS)
2001-02-01
The most distant X-ray cluster of galaxies yet has been found by astronomers using NASA’s Chandra X-ray Observatory. Approximately 10 billion light years from Earth, the cluster 3C294 is 40 percent farther than the next most distant X-ray galaxy cluster. The existence of such a distant galaxy cluster is important for understanding how the universe evolved. "Distant objects like 3C294 provide snapshots to how these galaxy clusters looked billions of years ago," said Andrew Fabian of the Institute of Astronomy, Cambridge, England and lead author of the paper accepted for publication in the Monthly Notices of Britain’s Royal Astronomical Society. "These latest results help us better understand what the universe was like when it was only 20 percent of its current age." Chandra’s image reveals an hourglass-shaped region of X-ray emission centered on the previously known central radio source. This X-ray emission extends outward from the central galaxy for at least 300,000 light years and shows that the known radio source is in the central galaxy of a massive cluster. Scientists have long suspected that distant radio-emitting galaxies like 3C294 are part of larger groups of galaxies known as "clusters." However, radio data provides astronomers with only a partial picture of these distant objects. Confirmation of the existence of clusters at great distances - and, hence, at early stages of the universe - requires information from other wavelengths. Optical observations can be used to pinpoint individual galaxies, but X-ray data are needed to detect the hot gas that fills the space within the cluster. "Galaxy clusters are the largest gravitationally bound structures in the universe," said Fabian. "We do not expect to find many massive objects, such as the 3C294 cluster, in early times because structure is thought to grow from small scales to large scales." The vast clouds of hot gas that envelope galaxies in clusters are thought to be heated by collapse toward the center of the cluster. Until Chandra, X-ray telescopes have not had the needed sensitivity to identify and measure hot gas clouds in distant clusters. Carolin Crawford, Stefano Ettori and Jeremy Sanders of the Institute of Astronomy were also members of the team that observed 3C294 for 5.4 hours on October 29, 2000 with the Advanced CCD Imaging Spectrometer (ACIS). The ACIS X-ray camera was developed for NASA by Pennsylvania State University and Massachusetts Institute of Technology. NASA's Marshall Space Flight Center in Huntsville, AL, manages the Chandra program for the Office of Space Science in Washington, DC. The Smithsonian's Chandra X-ray Center controls science and flight operations from Cambridge, MA. Images associated with this release are available on the World Wide Web at: http://chandra.harvard.edu AND http://chandra.nasa.gov
2012-01-01
Foot-and-mouth disease virus (FMDV) is a highly infectious member of the Picornaviridae inducing an acute disease of cloven-hoofed species. Vaccine-induced immune protection correlates with the presence of high levels of neutralizing antibodies but also opsonising antibodies have been proposed as an important mechanism of the immune response contributing to virus clearance by macrophages and leading to the production of type-I interferon (IFN) by plasmacytoid dendritic cells (pDC). The present study demonstrates that the opsonising antibody titres mediating enhanced IFN-α responses in pDC were similar to neutralizing titres, when antigenically related viruses from the same serotype were employed. However, sera cross-reacted also with non-neutralized isolates of multiple serotypes, when tested in this assay. Both uncomplexed virus and immune complexed virus stimulated pDC via Toll-like receptor 7. An additional finding of potential importance for strain-specific differences in virulence and/or immunogenicity was that pDC activation by FMDV strongly differed between viral isolates. Altogether, our results indicate that opsonising antibodies can have a broader reactivity than neutralizing antibodies and may contribute to antiviral responses induced against antigenically distant viruses. PMID:22934974
Synthesis and implementation of state-trajectory control law for dc-to-dc converters
NASA Technical Reports Server (NTRS)
Burns, W. W., III; Huffman, S. D.; Wilson, T. G.; Owen, H. A., Jr.
1977-01-01
Mathematical representations of a state-plane switching boundary employed in a state-trajectory control law for dc-to-dc converters are derived. Two approaches to implementing the control law are discussed; one approach employs a digital processor and the other uses analog computational circuits. Performance characteristics of experimental voltage step-up dc-to-dc converters operating under the control of each of these implementations are presented.
NASA Astrophysics Data System (ADS)
Geetha, A.; Subramani, C.; Thamizh Thentral, T. M.; Krithika, V.; Usha, S.
2018-04-01
Non isolated Bidirectional DC-DC Converter (NIBDDC) is a good interface between DC source and inverter Fed induction motor drive. This paper deals with comparison between open loop and PI controlled Bidirectional DC to DC Converter Inverter System (BDDCIS). The modelling and control of BDDC is becomes an important issue. Open loop BDDCIS and closed loop PI controlled BDDCIS are designed, modelled and simulated using Matlab- simulink and their results are presented. The investigations indicate superior performance of PI controlled BDDCIS. The proposed BDDCIS has advantages like bidirectional power transfer ability, reduced hardware count and improved dynamic response.
NASA Technical Reports Server (NTRS)
Pfaff, R.; Rowland, D.; Klenzing, J.; Freudenreich, H.; Bromund, K.; Liebrecht, C.; Roddy, P.; Hunton, D.
2009-01-01
DC electric field observations and associated plasma drifts gathered with the Vector Electric Field Investigation on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite typically reveal considerable variation at large scales (approximately 100's of km), in both daytime and nighttime cases, with enhanced structures usually confined to the nightside. Although such electric field structures are typically associated with plasma density depletions and structures, as observed by the Planar Langmuir Probe on C/NOFS, what is surprising is the number of cases in which large amplitude, structured DC electric fields are observed without a significant plasma density counterpart structure, including their appearance at times when the ambient plasma density appears relatively quiescent. We investigate the relationship of such structured DC electric fields and the ambient plasma density in the C/NOFS satellite measurements observed thus far, taking into account both plasma density depletions and enhancements. We investigate the mapping of the electric fields along magnetic field lines from distant altitudes and latitudes to locations where the density structures, which presumably formed the original seat of the electric fields, are no longer discernible in the observations. In some cases, the electric field structures and spectral characteristics appear to mimic those associated with equatorial spread-F processes, providing important clues to their origins. We examine altitude, seasonal, and longitudinal effects in an effort to establish the origin of such structured DC electric fields observed both with, and without, associated plasma density gradients
On Application of Model Predictive Control to Power Converter with Switching
NASA Astrophysics Data System (ADS)
Zanma, Tadanao; Fukuta, Junichi; Doki, Shinji; Ishida, Muneaki; Okuma, Shigeru; Matsumoto, Takashi; Nishimori, Eiji
This paper concerns a DC-DC converter control. In DC-DC converters, there exist both continuous components such as inductance, conductance and resistance and discrete ones, IGBT and MOSFET as semiconductor switching elements. Such a system can be regarded as a hybrid dynamical system. Thus, this paper presents a dc-dc control technique based on the model predictive control. Specifically, a case in which the load of the dc-dc converter changes from active to sleep is considered. In the case, a control method which makes the output voltage follow to the reference quickly in transition, and the switching frequency be constant in steady state. In addition, in applying the model predictive control to power electronics circuits, the switching characteristic of the device and the restriction condition for protection are also considered. The effectiveness of the proposed method is illustrated by comparing a conventional method through some simulation results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siddaramappa, Shivakumara; Delano, Susana; Green, Lance D.
2012-01-01
Dehalogenimonas lykanthroporepellens is the type species of the genus Dehalogenimonas, which belongs to a deeply branching lineage within the phylum Chloroflexi. This strictly anaerobic, mesophilic, non spore forming, Gram negative staining bacterium was first isolated from chlorinated solvent contaminated groundwater at a Superfund site located near Baton Rouge, Louisiana, USA. D. lykanthroporepellens was of interest for genome sequencing for two reasons: (a) its unusual ability to couple growth with reductive dechlorination of environmentally important polychlorinated aliphatic alkanes and (b) its phylogenetic position distant from previously sequenced bacteria. The 1,686,510 bp circular chromosome of strain BL-DC-9{sup T} contains 1,720 predicted proteinmore » coding genes, 47 tRNA genes, a single large subunit rRNA (23S-5S) locus, and a single, orphan, small unit rRNA (16S) locus.« less
NASA Technical Reports Server (NTRS)
Burns, W. W., III
1977-01-01
An analytically derived approach to the control of energy-storage dc-to-dc converters, which enables improved system performance and an extensive understanding of the manner in which this improved performance is accomplished, is presented. The control approach is derived from a state-plane analysis of dc-to-dc converter power stages which enables a graphical visualization of the movement of the system state during both steady state and transient operation. This graphical representation of the behavior of dc-to-dc converter systems yields considerable qualitative insight into the cause and effect relationships which exist between various commonly used converter control functions and the system performance which results from them.
Contreras, Vanessa; Urien, Céline; Guiton, Rachel; Alexandre, Yannick; Vu Manh, Thien-Phong; Andrieu, Thibault; Crozat, Karine; Jouneau, Luc; Bertho, Nicolas; Epardaud, Mathieu; Hope, Jayne; Savina, Ariel; Amigorena, Sebastian; Bonneau, Michel; Dalod, Marc; Schwartz-Cornil, Isabelle
2010-09-15
The mouse lymphoid organ-resident CD8alpha(+) dendritic cell (DC) subset is specialized in Ag presentation to CD8(+) T cells. Recent evidence shows that mouse nonlymphoid tissue CD103(+) DCs and human blood DC Ag 3(+) DCs share similarities with CD8alpha(+) DCs. We address here whether the organization of DC subsets is conserved across mammals in terms of gene expression signatures, phenotypic characteristics, and functional specialization, independently of the tissue of origin. We study the DC subsets that migrate from the skin in the ovine species that, like all domestic animals, belongs to the Laurasiatheria, a distinct phylogenetic clade from the supraprimates (human/mouse). We demonstrate that the minor sheep CD26(+) skin lymph DC subset shares significant transcriptomic similarities with mouse CD8alpha(+) and human blood DC Ag 3(+) DCs. This allowed the identification of a common set of phenotypic characteristics for CD8alpha-like DCs in the three mammalian species (i.e., SIRP(lo), CADM1(hi), CLEC9A(hi), CD205(hi), XCR1(hi)). Compared to CD26(-) DCs, the sheep CD26(+) DCs show 1) potent stimulation of allogeneic naive CD8(+) T cells with high selective induction of the Ifngamma and Il22 genes; 2) dominant efficacy in activating specific CD8(+) T cells against exogenous soluble Ag; and 3) selective expression of functional pathways associated with high capacity for Ag cross-presentation. Our results unravel a unifying definition of the CD8alpha(+)-like DCs across mammalian species and identify molecular candidates that could be used for the design of vaccines applying to mammals in general.
A Nonlinear Digital Control Solution for a DC/DC Power Converter
NASA Technical Reports Server (NTRS)
Zhu, Minshao
2002-01-01
A digital Nonlinear Proportional-Integral-Derivative (NPID) control algorithm was proposed to control a 1-kW, PWM, DC/DC, switching power converter. The NPID methodology is introduced and a practical hardware control solution is obtained. The design of the controller was completed using Matlab (trademark) Simulink, while the hardware-in-the-loop testing was performed using both the dSPACE (trademark) rapid prototyping system, and a stand-alone Texas Instruments (trademark) Digital Signal Processor (DSP)-based system. The final Nonlinear digital control algorithm was implemented and tested using the ED408043-1 Westinghouse DC-DC switching power converter. The NPID test results are discussed and compared to the results of a standard Proportional-Integral (PI) controller.
Daud, Muhamad Zalani; Mohamed, Azah; Hannan, M. A.
2014-01-01
This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV) system with battery energy storage (BES). The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC). For the grid side VSC (G-VSC), two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods. PMID:24883374
Daud, Muhamad Zalani; Mohamed, Azah; Hannan, M A
2014-01-01
This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV) system with battery energy storage (BES). The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC). For the grid side VSC (G-VSC), two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods.
A state-trajectory control law for dc-to-dc converters
NASA Technical Reports Server (NTRS)
Burns, W. W., III; Wilson, T. G.
1978-01-01
Mathematical representations of a state-plane switching boundary employed in a state-trajectory control law for dc-to-dc converters are derived. Several levels of approximation to the switching boundary equations are presented, together with an evaluation of the effects of nonideal operating characteristics of converter power stage components on the shape and location of the boundary and the behavior of a system controlled by it. Digital computer simulations of dc-to-dc converters operating in conjunction with each of these levels of control are presented and evaluated with respect to changes in transient and steady-state performance.
Hislop, T G; Lamb, C W; Ng, V T
1990-01-01
Cases (n = 263) and controls (n = 200) returned self-administered food frequency questionnaires in 1980-1982 and again in 1986 as part of a case-control study of breast cancer. The questionnaire asked about consumption of specific food items as recalled for four different age periods. K-statistics comparing responses in the first and second questionnaires were generally similar for cases and controls and were consistent across the different age periods. The influence of recent dietary change on dietary recall diminished for the more distant past. The food frequency questionnaire was found to be more reliable for specific food items for the distant past than for the more recent past. Differential misclassification bias between cases and controls was less apparent for the more distant past. The frequency and interpretation of missing values is discussed.
DC motor speed control using fuzzy logic controller
NASA Astrophysics Data System (ADS)
Ismail, N. L.; Zakaria, K. A.; Nazar, N. S. Moh; Syaripuddin, M.; Mokhtar, A. S. N.; Thanakodi, S.
2018-02-01
The automatic control has played a vital role in the advance of engineering and science. Nowadays in industries, the control of direct current (DC) motor is a common practice thus the implementation of DC motor controller speed is important. The main purpose of motor speed control is to keep the rotation of the motor at the present speed and to drive a system at the demand speed. The main purpose of this project is to control speed of DC Series Wound Motor using Fuzzy Logic Controller (FLC). The expectation of this project is the Fuzzy Logic Controller will get the best performance compared to dc motor without controller in terms of settling time (Ts), rise time (Tr), peak time (Tp) and percent overshoot (%OS).
Sliding-mode control of single input multiple output DC-DC converter
NASA Astrophysics Data System (ADS)
Zhang, Libo; Sun, Yihan; Luo, Tiejian; Wan, Qiyang
2016-10-01
Various voltage levels are required in the vehicle mounted power system. A conventional solution is to utilize an independent multiple output DC-DC converter whose cost is high and control scheme is complicated. In this paper, we design a novel SIMO DC-DC converter with sliding mode controller. The proposed converter can boost the voltage of a low-voltage input power source to a controllable high-voltage DC bus and middle-voltage output terminals, which endow the converter with characteristics of simple structure, low cost, and convenient control. In addition, the sliding mode control (SMC) technique applied in our converter can enhance the performances of a certain SIMO DC-DC converter topology. The high-voltage DC bus can be regarded as the main power source to the high-voltage facility of the vehicle mounted power system, and the middle-voltage output terminals can supply power to the low-voltage equipment on an automobile. In the respect of control algorithm, it is the first time to propose the SMC-PID (Proportion Integration Differentiation) control algorithm, in which the SMC algorithm is utilized and the PID control is attended to the conventional SMC algorithm. The PID control increases the dynamic ability of the SMC algorithm by establishing the corresponding SMC surface and introducing the attached integral of voltage error, which endow the sliding-control system with excellent dynamic performance. At last, we established the MATLAB/SIMULINK simulation model, tested performance of the system, and built the hardware prototype based on Digital Signal Processor (DSP). Results show that the sliding mode control is able to track a required trajectory, which has robustness against the uncertainties and disturbances.
Sliding-mode control of single input multiple output DC-DC converter.
Zhang, Libo; Sun, Yihan; Luo, Tiejian; Wan, Qiyang
2016-10-01
Various voltage levels are required in the vehicle mounted power system. A conventional solution is to utilize an independent multiple output DC-DC converter whose cost is high and control scheme is complicated. In this paper, we design a novel SIMO DC-DC converter with sliding mode controller. The proposed converter can boost the voltage of a low-voltage input power source to a controllable high-voltage DC bus and middle-voltage output terminals, which endow the converter with characteristics of simple structure, low cost, and convenient control. In addition, the sliding mode control (SMC) technique applied in our converter can enhance the performances of a certain SIMO DC-DC converter topology. The high-voltage DC bus can be regarded as the main power source to the high-voltage facility of the vehicle mounted power system, and the middle-voltage output terminals can supply power to the low-voltage equipment on an automobile. In the respect of control algorithm, it is the first time to propose the SMC-PID (Proportion Integration Differentiation) control algorithm, in which the SMC algorithm is utilized and the PID control is attended to the conventional SMC algorithm. The PID control increases the dynamic ability of the SMC algorithm by establishing the corresponding SMC surface and introducing the attached integral of voltage error, which endow the sliding-control system with excellent dynamic performance. At last, we established the MATLAB/SIMULINK simulation model, tested performance of the system, and built the hardware prototype based on Digital Signal Processor (DSP). Results show that the sliding mode control is able to track a required trajectory, which has robustness against the uncertainties and disturbances.
Suzuki, T; Sadakata, Y; Kashiwagi, K; Hoshino, K; Kakinuma, Y; Shirahata, A; Igarashi, K
1993-07-15
A variant cell line, termed SAM-1, which overproduced S-adenosylmethionine decarboxylase (AdoMetDC), was isolated by treatment of mouse FM3A cells with N-methyl-N'-nitro-N-nitrosoguanidine and subsequent incubation with ethylglyoxal bis(guanylhydrazone), an inhibitor of the enzyme. The cells were resistant to ethylglyoxal bis(guanylhydrazone), and showed AdoMetDC activity approximately five-times higher than control cells. The rate of AdoMetDC synthesis and the amount of AdoMetDC existing in SAM-1 cells were about five-times those in control cells. The amount of AdoMetDC mRNA existing in SAM-1 cells was five-times more than that in control cells. The amount of 5'-([(Z)-4-amino-2-butenyl]methylamino)-5'-deoxyadenosine, an irreversible inhibitor of AdoMetDC, necessary to inhibit cell growth was also five-times more in SAM-1 cells than in control cells. However, the following were the same in both SAM-1 and control cells; the amount of genomic DNA for AdoMetDC, the size and nucleotide sequence of 5' untranslated region of AdoMetDC mRNA, the deduced amino acid sequence (334 residues) from the nucleotide sequence of AdoMetDC cDNA and the degradation rate (t1/2 = about 4 h) of AdoMetDC. In addition, AdoMetDC mRNA in control cells was slightly more stable than that in SAM-1 cells. The results indicate that the overproduction of AdoMetDC in SAM-1 cells was caused by the increase of AdoMetDC mRNA. The variant cell line is convenient for studying the regulation of AdoMetDC and the physiological function of polyamines.
NASA Astrophysics Data System (ADS)
Borni, A.; Abdelkrim, T.; Zaghba, L.; Bouchakour, A.; Lakhdari, A.; Zarour, L.
2017-02-01
In this paper the model of a grid connected hybrid system is presented. The hybrid system includes a variable speed wind turbine controlled by aFuzzy MPPT control, and a photovoltaic generator controlled with PSO Fuzzy MPPT control to compensate the power fluctuations caused by the wind in a short and long term, the inverter currents injected to the grid is controlled by a decoupled PI current control. In the first phase, we start by modeling of the conversion system components; the wind system is consisted of a turbine coupled to a gearless permanent magnet generator (PMG), the AC/DC and DC-DC (Boost) converter are responsible to feed the electric energy produced by the PMG to the DC-link. The solar system consists of a photovoltaic generator (GPV) connected to a DC/DC boost converter controlled by a PSO fuzzy MPPT control to extract at any moment the maximum available power at the GPV terminals, the system is based on maximum utilization of both of sources because of their complementary. At the end. The active power reached to the DC-link is injected to the grid through a DC/AC inverter, this function is achieved by controlling the DC bus voltage to keep it constant and close to its reference value, The simulation studies have been performed using Matlab/Simulink. It can be concluded that a good control system performance can be achieved.
Analytic derivation and evaluation of a state-trajectory control law for dc-to-dc converters
NASA Technical Reports Server (NTRS)
Burns, W. W., III; Wilson, T. G.
1977-01-01
Mathematical representations of a state-plane switching boundary employed in a state-trajectory control law for dc-to-dc converters are derived. Several levels of approximation to the switching boundary equations are presented, together with an evaluation of the effects of nonideal operating characteristics of converter power stage components on the shape and location of the boundary and the behavior of a system controlled by it. Digital computer simulations of dc-to-dc converters operating in conjunction with each of these levels of control are presented and evaluated with respect to changes in transient and steady-state performance.
Methods, systems and apparatus for controlling operation of two alternating current (AC) machines
Gallegos-Lopez, Gabriel [Torrance, CA; Nagashima, James M [Cerritos, CA; Perisic, Milun [Torrance, CA; Hiti, Silva [Redondo Beach, CA
2012-02-14
A system is provided for controlling two AC machines. The system comprises a DC input voltage source that provides a DC input voltage, a voltage boost command control module (VBCCM), a five-phase PWM inverter module coupled to the two AC machines, and a boost converter coupled to the inverter module and the DC input voltage source. The boost converter is designed to supply a new DC input voltage to the inverter module having a value that is greater than or equal to a value of the DC input voltage. The VBCCM generates a boost command signal (BCS) based on modulation indexes from the two AC machines. The BCS controls the boost converter such that the boost converter generates the new DC input voltage in response to the BCS. When the two AC machines require additional voltage that exceeds the DC input voltage required to meet a combined target mechanical power required by the two AC machines, the BCS controls the boost converter to drive the new DC input voltage generated by the boost converter to a value greater than the DC input voltage.
Lin, Tao; Sun, Huijun; Chen, Zhong; You, Rongyi; Zhong, Jianhui
2007-12-01
Diffusion weighting in MRI is commonly achieved with the pulsed-gradient spin-echo (PGSE) method. When combined with spin-warping image formation, this method often results in ghosts due to the sample's macroscopic motion. It has been shown experimentally (Kennedy and Zhong, MRM 2004;52:1-6) that these motion artifacts can be effectively eliminated by the distant dipolar field (DDF) method, which relies on the refocusing of spatially modulated transverse magnetization by the DDF within the sample itself. In this report, diffusion-weighted images (DWIs) using both DDF and PGSE methods in the presence of macroscopic sample motion were simulated. Numerical simulation results quantify the dependence of signals in DWI on several key motion parameters and demonstrate that the DDF DWIs are much less sensitive to macroscopic sample motion than the traditional PGSE DWIs. The results also show that the dipolar correlation distance (d(c)) can alter contrast in DDF DWIs. The simulated results are in good agreement with the experimental results reported previously.
Low-to-Medium Power Single Chip Digital Controlled DC-DC Regulator for Point-of-Load Applications
NASA Technical Reports Server (NTRS)
Adell, Philippe C. (Inventor); Bakkaloglu, Bertan (Inventor); Vermeire, Bert (Inventor); Liu, Tao (Inventor)
2015-01-01
A DC-DC converter for generating a DC output voltage includes: a digitally controlled pulse width modulator (DPWM) for controlling a switching power stage to supply a varying voltage to an inductor; and a digital voltage feedback circuit for controlling the DPWM in accordance with a feedback voltage corresponding to the DC output voltage, the digital voltage feedback circuit including: a first voltage controlled oscillator for converting the feedback voltage into a first frequency signal and to supply the first frequency signal to a first frequency discriminator; a second voltage controlled oscillator for converting a reference voltage into a second frequency signal and to supply the second frequency signal to a second frequency discriminator; a digital comparator for comparing digital outputs of the first and second frequency discriminators and for outputting a digital feedback signal; and a controller for controlling the DPWM in accordance with the digital feedback signal.
Application handbook for a Standardized Control Module (SCM) for DC-DC converters, volume 1
NASA Astrophysics Data System (ADS)
Lee, F. C.; Mahmoud, M. F.; Yu, Y.
1980-04-01
The standardized control module (SCM) was developed for application in the buck, boost and buck/boost DC-DC converters. The SCM used multiple feedback loops to provide improved input line and output load regulation, stable feedback control system, good dynamic transient response and adaptive compensation of the control loop for changes in open loop gain and output filter time constraints. The necessary modeling and analysis tools to aid the design engineer in the application of the SCM to DC-DC Converters were developed. The SCM functional block diagram and the different analysis techniques were examined. The average time domain analysis technique was chosen as the basic analytical tool. The power stage transfer functions were developed for the buck, boost and buck/boost converters. The analog signal and digital signal processor transfer functions were developed for the three DC-DC Converter types using the constant on time, constant off time and constant frequency control laws.
Application handbook for a Standardized Control Module (SCM) for DC-DC converters, volume 1
NASA Technical Reports Server (NTRS)
Lee, F. C.; Mahmoud, M. F.; Yu, Y.
1980-01-01
The standardized control module (SCM) was developed for application in the buck, boost and buck/boost DC-DC converters. The SCM used multiple feedback loops to provide improved input line and output load regulation, stable feedback control system, good dynamic transient response and adaptive compensation of the control loop for changes in open loop gain and output filter time constraints. The necessary modeling and analysis tools to aid the design engineer in the application of the SCM to DC-DC Converters were developed. The SCM functional block diagram and the different analysis techniques were examined. The average time domain analysis technique was chosen as the basic analytical tool. The power stage transfer functions were developed for the buck, boost and buck/boost converters. The analog signal and digital signal processor transfer functions were developed for the three DC-DC Converter types using the constant on time, constant off time and constant frequency control laws.
NASA Astrophysics Data System (ADS)
Sudhakar, N.; Rajasekar, N.; Akhil, Saya; Jyotheeswara Reddy, K.
2017-11-01
The boost converter is the most desirable DC-DC power converter for renewable energy applications for its favorable continuous input current characteristics. In other hand, these DC-DC converters known as practical nonlinear systems are prone to several types of nonlinear phenomena including bifurcation, quasiperiodicity, intermittency and chaos. These undesirable effects has to be controlled for maintaining normal periodic operation of the converter and to ensure the stability. This paper presents an effective solution to control the chaos in solar fed DC-DC boost converter since the converter experiences wide range of input power variation which leads to chaotic phenomena. Controlling of chaos is significantly achieved using optimal circuit parameters obtained through Nelder-Mead Enhanced Bacterial Foraging Optimization Algorithm. The optimization renders the suitable parameters in minimum computational time. The results are compared with the traditional methods. The obtained results of the proposed system ensures the operation of the converter within the controllable region.
ERIC Educational Resources Information Center
Zumel, P.; Fernandez, C.; Sanz, M.; Lazaro, A.; Barrado, A.
2011-01-01
In this paper, a short introductory course to introduce field-programmable gate array (FPGA)-based digital control of dc/dc switching power converters is presented. Digital control based on specific hardware has been at the leading edge of low-medium power dc/dc switching converters in recent years. Besides industry's interest in this topic, from…
Decentralized Interleaving of Paralleled Dc-Dc Buck Converters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Brian B; Rodriguez, Miguel; Sinha, Mohit
We present a decentralized control strategy that yields switch interleaving among parallel-connected dc-dc buck converters. The proposed method is based on the digital implementation of the dynamics of a nonlinear oscillator circuit as the controller. Each controller is fully decentralized, i.e., it only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform and no communication between different controllers is needed. By virtue of the intrinsic electrical coupling between converters, the nonlinear oscillator-based controllers converge to an interleaved state with uniform phase-spacing across PWM carriers. To the knowledge of the authors, this work presents themore » first fully decentralized strategy for switch interleaving in paralleled dc-dc buck converters.« less
Research of digital controlled DC/DC converter based on STC12C5410AD
NASA Astrophysics Data System (ADS)
Chen, Dan-Jiang; Jin, Xin; Xiao, Zhi-Hong
2010-02-01
In order to study application of digital control technology on DC/DC converter, principle of increment mode PID control algorithm was analyzed in the paper. Then, a SCM named STC12C5410AD was introduced with its internal resources and characteristics. The PID control algorithm can be implemented easily based on it. The output of PID control was used to change the value of a variable that is 255 times than duty cycle, and this reduced the error of calculation. The valid of the presented algorithm was verified by an experiment for a BUCK DC/DC converter. The experimental results indicated that output voltage of the BUCK converter is stable with low ripple.
Modified Perfect Harmonics Cancellation Control of a Grid Interfaced SPV Power Generation
NASA Astrophysics Data System (ADS)
Singh, B.; Shahani, D. T.; Verma, A. K.
2015-03-01
This paper deals with a grid interfaced solar photo voltaic (SPV) power generating system with modified perfect harmonic cancellation (MPHC) control for power quality improvement in terms of mitigation of the current harmonics, power factor correction, control of point of common coupling (PCC) voltage with reactive power compensation and load balancing in a three phase distribution system. The proposed grid interfaced SPV system consists of a SPV array, a dc-dc boost converter and a voltage source converter (VSC) used for the compensation of other connected linear and nonlinear loads at PCC. The reference grid currents are estimated using MPHC method and control signals are derived by using pulse width modulation (PWM) current controller of VSC. The SPV power is fed to the common dc bus of VSC and dc-dc boost converter using maximum power point tracking (MPPT). The dc link voltage of VSC is regulated by using dc voltage proportional integral (PI) controller. The analysis of the proposed SPV power generating system is carried out under dc/ac short circuit and severe SPV-SX and SPV-TX intrusion.
Integrated-Circuit Controller For Brushless dc Motor
NASA Technical Reports Server (NTRS)
Le, Dong Tuan
1994-01-01
Generic circuit performs commutation-logic and power-switching functions for control of brushless dc motor. Controller includes commutation-logic and associated control circuitry, power supply, and inverters containing power transistors. Major advantages of controller are size, weight, and power consumption can be made less than other brushless-dc-motor controllers.
2017-04-28
Regional Air Component Commander (the Leader) 5 CC-DC- DE Solution to A2/AD – Distributed Theater Air Control System (the System) 9 CC-DC- DE ... Control , Decentralized Execution” to a new framework of “Centralized Command, Distributed Control , and Decentralized Execution” (CC-DC- DE ).4 5 This...USAF C2 challenges in A2/AD environments describes a three-part Centralized Command, Distributed Control , and Decentralized Execution (CC-DC- DE
NASA Technical Reports Server (NTRS)
Schwab, J. R.
1979-01-01
Performance data obtained through experimental testing of a 22.4 kW traction motor using two types of excitation are presented. Ripple free dc from a motor-generator set for baseline data and pulse width modulated dc as supplied by a battery pack and chopper controller were used for excitation. For the same average values of input voltage and current, the motor power output was independent of the type of excitation. However, at the same speeds, the motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points lower on chopped dc than on ripple free dc. The chopped dc locked-rotor torque was approximately 1 to 3 percent greater than the ripple free dc torque for the same average current.
DC-based magnetic field controller
Kotter, Dale K.; Rankin, Richard A.; Morgan, John P,.
1994-01-01
A magnetic field controller for laboratory devices and in particular to dc operated magnetic field controllers for mass spectrometers, comprising a dc power supply in combination with improvements to a hall probe subsystem, display subsystem, preamplifier, field control subsystem, and an output stage.
Decentralized Interleaving of Paralleled Dc-Dc Buck Converters: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Brian B; Rodriguez, Miguel; Sinha, Mohit
We present a decentralized control strategy that yields switch interleaving among parallel connected dc-dc buck converters without communication. The proposed method is based on the digital implementation of the dynamics of a nonlinear oscillator circuit as the controller. Each controller is fully decentralized, i.e., it only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform. By virtue of the intrinsic electrical coupling between converters, the nonlinear oscillator-based controllers converge to an interleaved state with uniform phase-spacing across PWM carriers. To the knowledge of the authors, this work represents the first fully decentralized strategy formore » switch interleaving of paralleled dc-dc buck converters.« less
DOWNSTREAM-WATER-LEVEL CONTROL TEST RESULTS ON THE WM LATERAL CANAL
USDA-ARS?s Scientific Manuscript database
On steep canals, distant downstream water-level control can be challenging. SacMan (Software for Automated Canal Management) was developed, in part, to test various distant downstream water level controllers. It was implemented on the WM canal of the Maricopa Stanfield Irrigation and Drainage Distri...
NASA Astrophysics Data System (ADS)
Dehkordi, N. Mahdian; Sadati, N.; Hamzeh, M.
2017-09-01
This paper presents a robust dc-link voltage as well as a current control strategy for a bidirectional interlink converter (BIC) in a hybrid ac/dc microgrid. To enhance the dc-bus voltage control, conventional methods strive to measure and feedforward the load or source power in the dc-bus control scheme. However, the conventional feedforward-based approaches require remote measurement with communications. Moreover, conventional methods suffer from stability and performance issues, mainly due to the use of the small-signal-based control design method. To overcome these issues, in this paper, the power from DG units of the dc subgrid imposed on the BIC is considered an unmeasurable disturbance signal. In the proposed method, in contrast to existing methods, using the nonlinear model of BIC, a robust controller that does not need the remote measurement with communications effectively rejects the impact of the disturbance signal imposed on the BIC's dc-link voltage. To avoid communication links, the robust controller has a plug-and-play feature that makes it possible to add a DG/load to or remove it from the dc subgrid without distorting the hybrid microgrid stability. Finally, Monte Carlo simulations are conducted to confirm the effectiveness of the proposed control strategy in MATLAB/SimPowerSystems software environment.
Power and Energy Management Strategy for Solid State Transformer Interfaced DC Microgrid
NASA Astrophysics Data System (ADS)
Yu, Xunwei
As a result of more and more applications of renewable energy into our ordinary life, how to construct a microgrid (MG) based on the distributed renewable energy resources and energy storages, and then to supply a reliable and flexible power to the conventional power system are the hottest topics nowadays. Comparing to the AC microgrid (AC MG), DC microgrid (DC MG) gets more attentions, because it has its own advantages, such as high efficiency, easy to integrate the DC energy sources and energy storages, and so on. Furthermore, the interaction between DC MG system and the distribution system is also an important and practical issue. In Future Renewable Electric Energy Delivery and Management Systems Center (FREEDM), the Solid State Transformer (SST) is built, which can transform the distribution system to the low AC and DC system directly (usually home application level). Thus, the SST gives a new promising solution for low voltage level MG to interface the distribution level system instead of the traditional transformer. So a SST interfaced DC MG is proposed. However, it also brings new challenges in the design and control fields for this system because the system gets more complicated, which includes distributed energy sources and storages, load, and SST. The purpose of this dissertation is to design a reliable and flexible SST interfaced DC MG based on the renewable energy sources and energy storages, which can operate in islanding mode and SST-enabled mode. Dual Half Bridge (DHB) is selected as the topology for DC/DC converter in DC MG. The DHB operation procedure and average model are analyzed, which is the basis for the system modeling, control and operation. Furthermore, two novel power and energy management strategies are proposed. The first one is a distributed energy management strategy for the DC MG operating in the SST-enabled mode. In this method, the system is not only in distributed control to increase the system reliability, but the power sharing between DC MG and SST, State of Charge (SOC) for battery, are both considered in the system energy management strategy. Then the DC MG output power is controllable and the battery is autonomous charged and discharged based on its SOC and system information without communication. The system operation modes are defined, analyzed and the simulation results verify the strategy. The second power and energy management strategy is the hierarchical control. In this control strategy, three-layer control structure is presented and defined. The first layer is the primary control for the DC MG in islanding mode, which is to guarantee the DC MG system power balance without communication to increase the system reliability. The second control layer is to implement the seamless switch for DC MG system from islanding mode to SST-enabled mode. The third control layer is the tertiary control for the system energy management and the communication is also involved. The tertiary layer not only controls the whole DC MG output power, but also manages battery module charge and discharge statuses based on its SOC. The simulation and experimental results verify the methods. Some practical issues for the SST interfaced DC MG are also investigated. Power unbalance issue of SST is analyzed and a distributed control strategy is presented to solve this problem. Simulation and experimental results verify it. Furthermore, the control strategy for SST interfaced DC MG blackout is presented and the simulation results are shown to valid it. Also a plug and play SST interfaced DC MG is constructed and demonstrated. Several battery and PV modules construct a typical DC MG and a DC source is adopted to simulate the SST. The system is in distributed control and can operate in islanding mode and SST-enabled mode. The experimental results verify that individual module can plug into and unplug from the DC MG randomly without affecting the system stability. Furthermore, the communication ports are embedded into the system and a universal communication protocol is proposed to implement the plug and play function. Specified ID is defined for individual PV and battery for system recognition. A database is built to store the whole system date for visual display, monitor and history query.
DC servo motor positioning with anti-windup implementation using C2000 ARM-Texas Instrument
NASA Astrophysics Data System (ADS)
Linggarjati, Jimmy
2017-12-01
One of the most important topics in control system is DC Motor. At this research, a positioning control system for a DC motor is investigated. Firstly, the DC Motor will be paramaterized to get the transfer function model, in order to be simulated in Matlab, and then implemented in a C2000-ARM microcontroller from TI (Texas Instrument). With this investigation, students in control system theory will be able to understand the importance of classical control theories, in relation to the real world implementation of the position control for the DC Motor, escpecially the importance of Anti-Windup technique in real-world implementation.
Variable Rail Voltage Control of a Brushless DC (BLDC) Motor
2013-01-01
Variable Rail Voltage Control of a Brushless DC ( BLDC ) Motor by Yuan Chen, Joseph Conroy, and William Nothwang ARL-TR-6308 January 2013...TR-6308 January 2013 Variable Rail Voltage Control of a Brushless DC ( BLDC ) Motor Yuan Chen, Joseph Conroy, and William Nothwang Sensors...DATES COVERED (From - To) 4. TITLE AND SUBTITLE Variable Rail Voltage Control of a Brushless DC ( BLDC ) Motor 5a. CONTRACT NUMBER 5b. GRANT
A Review of Microgrid Architectures and Control Strategy
NASA Astrophysics Data System (ADS)
Jadav, Krishnarajsinh A.; Karkar, Hitesh M.; Trivedi, I. N.
2017-12-01
In this paper microgrid architecture and various converters control strategies are reviewed. Microgrid is defined as interconnected network of distributed energy resources, loads and energy storage systems. This emerging concept realizes the potential of distributed generators. AC microgrid interconnects various AC distributed generators like wind turbine and DC distributed generators like PV, fuel cell using inverter. While in DC microgrid output of an AC distributed generator must be converted to DC using rectifiers and DC distributed generator can be directly interconnected. Hybrid microgrid is the solution to avoid this multiple reverse conversions AC-DC-AC and DC-AC-DC that occur in the individual AC-DC microgrid. In hybrid microgrid all AC distributed generators will be connected in AC microgrid and DC distributed generators will be connected in DC microgrid. Interlinking converter is used for power balance in both microgrids, which transfer power from one microgrid to other if any microgrid is overloaded. At the end, review of interlinking converter control strategies is presented.
AC/DC Smart Control And Power Sharing of DC Distribution Systems
2012-02-10
system losses will decrease since the semiconductor losses due to switching in converter are reduced. The use of DC power systems to supply...cells yield variable DC voltage. In stand-alone systems , in order to be able to make full use of the generated power and to feed the loads, a controlled...alternate sources connected to the DC Distribution System
Application of drive circuit based on L298N in direct current motor speed control system
NASA Astrophysics Data System (ADS)
Yin, Liuliu; Wang, Fang; Han, Sen; Li, Yuchen; Sun, Hao; Lu, Qingjie; Yang, Cheng; Wang, Quanzhao
2016-10-01
In the experiment of researching the nanometer laser interferometer, our design of laser interferometer circuit system is up to the wireless communication technique of the 802.15.4 IEEE standard, and we use the RF TI provided by Basic to receive the data on speed control system software. The system's hardware is connected with control module and the DC motor. However, in the experiment, we found that single chip microcomputer control module is very difficult to drive the DC motor directly. The reason is that the DC motor's starting and braking current is larger than the causing current of the single chip microcomputer control module. In order to solve this problem, we add a driving module that control board can transmit PWM wave signal through I/O port to drive the DC motor, the driving circuit board can come true the function of the DC motor's positive and reversal rotation and speed adjustment. In many various driving module, the L298N module's integrated level is higher compared with other driver module. The L298N model is easy to control, it not only can control the DC motor, but also achieve motor speed control by modulating PWM wave that the control panel output. It also has the over-current protection function, when the motor lock, the L298N model can protect circuit and motor. So we use the driver module based on L298N to drive the DC motor. It is concluded that the L298N driver circuit module plays a very important role in the process of driving the DC motor in the DC motor speed control system.
NASA Technical Reports Server (NTRS)
Huffman, S. D.; Burns, W. W., III; Wilson, T. G.; Owen, H. A., Jr.
1976-01-01
Implementations of a state-plane-trajectory control law for energy storage dc-to-dc converters are presented. Performance characteristics of experimental voltage step-up converter systems employing these implementations are reported and compared to theoretical predictions.
NASA Astrophysics Data System (ADS)
Zhou, Ning; Yang, Jia; Cheng, Zheng; Chen, Bo; Su, Yong Chun; Shu, Zhan; Zou, Jin
2017-06-01
Solar photovoltaic power generation is the power generation using solar cell module converting sunlight into DC electric energy. In the paper an equivalent model of solar photovoltaic power generation system is built in RTDS. The main circuit structure of the two-stage PV grid-connected system consists of the DC-DC, DC-AC circuit. The MPPT (Maximum Power Point Tracking) control of the PV array is controlled by adjusting the duty ratio of the DC-DC circuit. The proposed control strategy of constant voltage/constant reactive power (V/Q) control is successfully implemented grid-connected control of the inverter when grid-connected operation. The closed-loop experiment of islanding protection device of photovoltaic power plant on RTDS, verifies the correctness of the simulation model, and the experimental verification can be applied to this type of device.
Emulating DC constant power load: a robust sliding mode control approach
NASA Astrophysics Data System (ADS)
Singh, Suresh; Fulwani, Deepak; Kumar, Vinod
2017-09-01
This article presents emulation of a programmable power electronic, constant power load (CPL) using a dc/dc step-up (boost) converter. The converter is controlled by a robust sliding mode controller (SMC). A novel switching surface is proposed to ensure a required power sunk by the converter. The proposed dc CPL is simple in design, has fast dynamic response and high accuracy, and offers an inexpensive alternative to study converters for cascaded dc distribution power system applications. Furthermore, the proposed CPL is sufficiently robust against the input voltage variations. A laboratory prototype of the proposed dc CPL has been developed and validated with SMC realised through OPAL-RT platform. The capability of the proposed dc CPL is confirmed via experimentations in varied scenarios.
Building stones of our Nation's Capital
Withington, Charles F.
1975-01-01
The buildings of our Nation's Capital serve as an unusual geologic display, for the city has been constructed with rocks from quarries throughout the United States and many distant lands. Each building is a unique museum that not only displays the important features of various stones and the geologic environment in which they were formed, but also serves as an historic witness to the city's growth and to the development of its architecture. This booklet describes the source and appearance of the stones used in Washington, D.C.; it includes a map and a walking guide to assist the visitor in examining them.
The ISPM unified radio and plasma wave experiment
NASA Technical Reports Server (NTRS)
Stone, R. G.; Caldwell, J.; Deconchy, Y.; Deschanciaux, C.; Ebbett, R.; Epstein, G.; Groetz, K.; Harvey, C. C.; Hoang, S.; Howard, R.
1983-01-01
Hardware for the International Solar Polar Mission (ISPM) Unified Radio and Plasma (URAP) wave experiment is presented. The URAP determines direction and polarization of distant radio sources for remote sensing of the heliosphere, and studies local wave phenomena which determine the transport coefficients of the ambient plasma. Electric and magnetic field antennas and preamplifiers; the electromagnetic compatibility plan and grounding; radio astronomy and plasma frequency receivers; a fast Fourier transformation data processing unit waveform analyzer; dc voltage measurements; a fast envelope sampler for the solar wind, and plasmas near Jupiter; a sounder; and a power converter are described.
NASA Technical Reports Server (NTRS)
Schoenfeld, A. D.; Yu, Y.
1973-01-01
Versatile standardized pulse modulation nondissipatively regulated control signal processing circuits were applied to three most commonly used dc to dc power converter configurations: (1) the series switching buck-regulator, (2) the pulse modulated parallel inverter, and (3) the buck-boost converter. The unique control concept and the commonality of control functions for all switching regulators have resulted in improved static and dynamic performance and control circuit standardization. New power-circuit technology was also applied to enhance reliability and to achieve optimum weight and efficiency.
Chaos minimization in DC-DC boost converter using circuit parameter optimization
NASA Astrophysics Data System (ADS)
Sudhakar, N.; Natarajan, Rajasekar; Gourav, Kumar; Padmavathi, P.
2017-11-01
DC-DC converters are prone to several types of nonlinear phenomena including bifurcation, quasi periodicity, intermittency and chaos. These undesirable effects must be controlled for periodic operation of the converter to ensure the stability. In this paper an effective solution to control of chaos in solar fed DC-DC boost converter is proposed. Controlling of chaos is significantly achieved using optimal circuit parameters obtained through Bacterial Foraging Optimization Algorithm. The optimization renders the suitable parameters in minimum computational time. The obtained results are compared with the operation of traditional boost converter. Further the obtained results with BFA optimized parameter ensures the operations of the converter are within the controllable region. To elaborate the study of bifurcation analysis with optimized and unoptimized parameters are also presented.
Hosain, M D Kamal; Kouzani, Abbas Z; Tye, Susannah J; Abulseoud, Osama A; Amiet, Andrew; Galehdar, Amir; Kaynak, Akif; Berk, Michael
2014-01-01
Design of a rectangular spiral planar inverted-F antenna (PIFA) at 915 MHz for wireless power transmission applications is proposed. The antenna and rectifying circuitry form a rectenna, which can produce dc power from a distant radio frequency energy transmitter. The generated dc power is used to operate a low-power deep brain stimulation pulse generator. The proposed antenna has the dimensions of 10 mm [Formula: see text]12.5 mm [Formula: see text]1.5 mm and resonance frequency of 915 MHz with a measured bandwidth of 15 MHz at return loss of [Formula: see text]. A dielectric substrate of FR-4 of [Formula: see text] and [Formula: see text] with thickness of 1.5 mm is used for both antenna and rectifier circuit simulation and fabrication because of its availability and low cost. An L-section impedance matching circuit is used between the PIFA and voltage doubler rectifier. The impedance matching circuit also works as a low-pass filter for elimination of higher order harmonics. Maximum dc voltage at the rectenna output is 7.5 V in free space and this rectenna can drive a deep brain stimulation pulse generator at a distance of 30 cm from a radio frequency energy transmitter, which transmits power of 26.77 dBm.
Modular high voltage power supply for chemical analysis
Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA
2007-01-09
A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.
Modular high voltage power supply for chemical analysis
Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA
2010-05-04
A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.
Modular high voltage power supply for chemical analysis
Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA
2008-07-15
A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.
Hua, Ming; Tao, Ming-Jie; Deng, Fu-Guo; Lu Long, Gui
2015-01-01
We propose a scheme to construct the controlled-phase (c-phase) gate on distant transmon qutrits hosted in different resonators inter-coupled by a connected transmon qutrit. Different from previous works for entanglement generation and information transfer on two distant qubits in a dispersive regime in the similar systems, our gate is constructed in the resonant regime with one step. The numerical simulation shows that the fidelity of our c-phase gate is 99.5% within 86.3 ns. As an interesting application of our c-phase gate, we propose an effective scheme to complete a conventional square lattice of two-dimensional surface code layout for fault-tolerant quantum computing on the distant transmon qutrits. The four-step coupling between the nearest distant transmon qutrits, small coupling strengths of the distant transmon qutrits, and the non-population on the connection transmon qutrit can reduce the interactions among different parts of the layout effectively, which makes the layout be integrated with a large scale in an easier way. PMID:26486426
Dexmedetomidine protects from post-myocardial ischaemia reperfusion lung damage in diabetic rats
Kip, Gülay; Çelik, Ali; Bilge, Mustafa; Alkan, Metin; Kiraz, Hasan Ali; Özer, Abdullah; Şıvgın, Volkan; Erdem, Özlem; Arslan, Mustafa; Kavutçu, Mustafa
2015-01-01
Objective Diabetic complications and lipid peroxidation are known to have a close association. Lipid peroxidation commonly occurs at sites exposed to ischaemia, but distant organs and tissues also get damaged during ischaemia/reperfusion (I/R). Some of these targets are vital organs, such as the lung, liver, and kidney; the lung is the most frequently affected. The aim of our study was to investigate the effects of dexmedetomidine on I/R damage in lung tissue and on the oxidant/anti-oxidant system in diabetic rats. Material and methods Diabetes was induced with streptozotocin (55 mg/kg) in 18 Wistar Albino rats, which were then randomly divided into three groups (diabetes control (DC), diabetes plus ischaemia-reperfusion (DIR), and diabetes plus dexmedetomidine-ischaemia/reperfusion (DIRD)) after the effects of diabetes were clearly evident. The rats underwent a left thoracotomy and then ischaemia was produced in the myocardium muscle by a left anterior descending artery ligation for 30 min in the DIR and DIRD groups. I/R was performed for 120 min. The DIRD group received a single intraperitoneal dose of dexmedetomidine (100 µg/kg); the DIR group received no dexmedetomidine. Group DC was evaluated as the diabetic control group and also included six rats (C group) in which diabetes was not induced. These mice underwent only left thoracotomy and were closed without undergoing myocardial ischaemia. Histopathological changes, activities of catalase (CAT) and glutathione-S-transferase anti-oxidant enzymes, and malondialdehyde (MDA) levels were evaluated in the lung tissues of all rats. Results Neutrophil infiltration/aggregation was higher in the DIR group than in the C, DC, and DIRD groups (p=0.001, p=0.013, and p=0.042, respectively). The lung injury score was significantly higher in the DIR group than in the C and DC groups (p<0.0001 and p=0.024, respectively). The levels of MDA were significantly higher in the DIR group than in the C and DIRD groups. CAT activity was significantly higher in the DIR group than in the DIRD and C groups. Conclusion Our results confirm that dexmedetomidine has protective effects against the lung damage resulting from I/R in diabetic rats. Future studies conducted to evaluate the effects of the use of dexmedetomidine on damage to various organs following different I/R durations may help understanding possible protective effects of dexmedetomidine and underlying mechanisms in tissue damage related to I/R injury. PMID:26387799
Implementation method of multi-terminal DC control system
NASA Astrophysics Data System (ADS)
Yi, Liu; Hao-Ran, Huang; Jun-Wen, Zhou; Hong-Guang, Guo; Yu-Yong, Zhou
2018-04-01
Currently the multi-terminal DC system (MTDC) has more stations. Each station needs operators to monitor and control the device. It needs much more operation and maintenance, low efficiency and small reliability; for the most important reason, multi-terminal DC system has complex control mode. If one of the stations has some problem, the control of the whole system should have problems. According to research of the characteristics of multi-terminal DC (VSC-MTDC) systems, this paper presents a strong implementation of the multi-terminal DC Supervisory Control and Data Acquisition (SCADA) system. This system is intelligent, can be networking, integration and intelligent. A master control system is added in each station to communication with the other stations to send current and DC voltage value to pole control system for each station. Based on the practical application and information feedback in the China South Power Grid research center VSC-MTDC project, this system is higher efficiency and save the cost on the maintenance of convertor station to improve the intelligent level and comprehensive effect. And because of the master control system, a multi-terminal system hierarchy coordination control strategy is formed, this make the control and protection system more efficiency and reliability.
A Single-Phase Embedded Z-Source DC-AC Inverter
Kim, Se-Jin; Lim, Young-Cheol
2014-01-01
In the conventional DC-AC inverter consisting of two DC-DC converters with unipolar output capacitors, the output capacitor voltages of the DC-DC converters must be higher than the DC input voltage. To overcome this weakness, this paper proposes a single-phase DC-AC inverter consisting of two embedded Z-source converters with bipolar output capacitors. The proposed inverter is composed of two embedded Z-source converters with a common DC source and output AC load. Though the output capacitor voltages of the converters are relatively low compared to those of a conventional inverter, an equivalent level of AC output voltages can be obtained. Moreover, by controlling the output capacitor voltages asymmetrically, the AC output voltage of the proposed inverter can be higher than the DC input voltage. To verify the validity of the proposed inverter, experiments were performed with a DC source voltage of 38 V. By controlling the output capacitor voltages of the converters symmetrically or asymmetrically, the proposed inverter can produce sinusoidal AC output voltages. The experiments show that efficiencies of up to 95% and 97% can be achieved with the proposed inverter using symmetric and asymmetric control, respectively. PMID:25133241
A single-phase embedded Z-source DC-AC inverter.
Kim, Se-Jin; Lim, Young-Cheol
2014-01-01
In the conventional DC-AC inverter consisting of two DC-DC converters with unipolar output capacitors, the output capacitor voltages of the DC-DC converters must be higher than the DC input voltage. To overcome this weakness, this paper proposes a single-phase DC-AC inverter consisting of two embedded Z-source converters with bipolar output capacitors. The proposed inverter is composed of two embedded Z-source converters with a common DC source and output AC load. Though the output capacitor voltages of the converters are relatively low compared to those of a conventional inverter, an equivalent level of AC output voltages can be obtained. Moreover, by controlling the output capacitor voltages asymmetrically, the AC output voltage of the proposed inverter can be higher than the DC input voltage. To verify the validity of the proposed inverter, experiments were performed with a DC source voltage of 38 V. By controlling the output capacitor voltages of the converters symmetrically or asymmetrically, the proposed inverter can produce sinusoidal AC output voltages. The experiments show that efficiencies of up to 95% and 97% can be achieved with the proposed inverter using symmetric and asymmetric control, respectively.
Control of DC gas flow in a single-stage double-inlet pulse tube cooler
NASA Astrophysics Data System (ADS)
Wang, C.; Thummes, G.; Heiden, C.
The use of double-inlet mode in the pulse tube cooler opens up a possibility of DC gas flow circulating around the regenerator and pulse tube. Numerical analysis shows that effects of DC flow in a single-stage pulse tube cooler are different in some aspects from that in a 4 K pulse tube cooler. For highest cooler efficiency, DC flow should be compensated to a small value, i.e. DC flow over average AC flow at regenerator inlet should be in the range -0.0013 to +0.00016. Dual valves with reversed asymmetric geometries were used for the double-inlet bypass to control the DC flow in this paper. The experiment, performed in a single-stage double-inlet pulse tube cooler, verified that the cooler performance can be significantly improved by precisely controlling the DC flow.
Analysis and Control of Pulse-Width Modulated AC to DC Voltage Source Converters.
NASA Astrophysics Data System (ADS)
Wu, Rusong
The pulse width modulated AC to DC voltage source converter is comprehensively analyzed in the thesis. A general mathematical model of the converter is first established, which is discontinuous, time-variant and non-linear. The following three techniques are used to obtain closed form solutions: Fourier analysis, transformation of reference frame and small signal linearization. Three models, namely, a steady-state DC model, a low frequency small signal AC model and a high frequency model, are consequently developed. Finally, three solution sets, namely, the steady-state solution, various dynamic transfer functions and the high frequency harmonic components, are obtained from the three models. Two control strategies, the Phase and Amplitude Control (PAC) and a new proposed strategy, Predicted Current Control with a Fixed Switching Frequency (PCFF), are investigated. Based on the transfer functions derived from the above mentioned analysis, regulators for a closed-loop control are designed. A prototype circuit is built to experimentally verify the theoretical predictions. The analysis and experimental results show that both strategies produce nearly sinusoidal line current with unity power factor on the utility side in both rectifying and regenerating operations and concurrently provide a regulated DC output voltage on the load side. However the proposed PCFF control has a faster and improved dynamic response over the PAC control. Moreover it is also easier to be implemented. Therefore, the PCFF control is preferable to the PAC control. As an example of application, a configuration of variable DC supply under PCFF control is proposed. The quasi-optimal dynamic response obtained shows that the PWM AC to DC converter lays the foundation for building a four-quadrant, fast-dynamic system, and the PCFF control is an effective strategy for improving dynamic performances not only as applied to the AC to DC converter, but also as applied to the DC to DC chopper or other circuits.
State trajectories used to observe and control dc-to-dc converters
NASA Technical Reports Server (NTRS)
Burns, W. W., III; Wilson, T. G.
1976-01-01
State-plane analysis techniques are employed to study the voltage stepup energy-storage dc-to-dc converter. Within this framework, an example converter operating under the influence of a constant on-time and a constant frequency controller is examined. Qualitative insight gained through this approach is used to develop a conceptual free-running control law for the voltage stepup converter which can achieve steady-state operation in one on/off cycle of control. Digital computer simulation data are presented to illustrate and verify the theoretical discussions presented.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-19
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-698 (Enforcement Proceeding)] Certain DC-DC Controllers and Products Containing Same; Decision To Affirm-in-Part, Reverse-in-Part, Modify-in... 1930, as amended, 19 U.S.C. 1337, and in section 210.75 of the Commission's Rules of Practice and...
Pagliaro, Gioacchino; Pandolfi, Paolo; Collina, Natalina; Frezza, Giovanni; Brandes, Alba; Galli, Margherita; Avventuroso, Federica Marzocchi; De Lisio, Sara; Musti, Muriel Assunta; Franceschi, Enrico; Esposti, Roberta Degli; Lombardo, Laura; Cavallo, Giovanna; Di Battista, Monica; Rimondini, Simonetta; Poggi, Rosalba; Susini, Cinzia; Renzi, Rina; Marconi, Linda
2016-01-01
Tong Len meditation is an important therapeutic tool in the Tibetan medicine, and it can be used for self-healing and/or to heal others. Currently, in the West, there is no scientific study concerning the efficacy of a Tong Len distant healing effect on psychological disorders in cancer patients. To evaluate a distant healing effect of Tong Len meditation on stress, anxiety, depression, fatigue, and self-perceived quality of life in cancer patients. These psychological objectives were chosen as a consequence of the limited scientific literature of present day. We performed a double-blind randomized controlled trial on 103 cancer patients with tumors. Overall, 12 meditators used Tong Len in aid of 52 patients randomly selected as experimental group, while the remaining 51 patients constituted the control group. Patients and meditators did not know each other. All patients completed profile of mood states (POMS) and European Quality of Life-5 dimensions (EQ-5D) questionnaires before treatment (T0), after two (T1) and three months of treatment (T2), and one month after treatment cessation (T3). With regard to the parameters related to depression, a statistically significant improvement (P = .003) was observed in the treatment group compared to controls. On the other hand, the vigor/activity parameter saw significant improvements in the control group (P = .009). Both groups exhibited significant improvements in the other factors assessed in the POMS and EQ-5D questionnaires. This study did not provide sufficient evidence supporting an efficacy of Tong Len meditation in distant psychological healing as compared to a control condition. The research highlighted some psychological improvements through Tong Len distant meditation in a group of patients unknown to meditators. Therefore, the enhancement detected in most parameters in both treatment and control groups raises interest on in-depth analysis and evaluation of distant meditation on cancer patients to mitigate psychological problems caused by the disease. Copyright © 2016 Elsevier Inc. All rights reserved.
Fast-response free-running dc-to-dc converter employing a state-trajectory control law
NASA Technical Reports Server (NTRS)
Huffman, S. D.; Burns, W. W., III; Wilson, T. G.; Owen, H. A., Jr.
1977-01-01
A recently proposed state-trajectory control law for a family of energy-storage dc-to-dc converters has been implemented for the voltage step-up configuration. Two methods of realization are discussed; one employs a digital processor and the other uses analog computational circuits. Performance characteristics of experimental voltage step-up converters operating under the control of each of these implementations are reported and compared to theoretical predictions and computer simulations.
Single Stage Rocket Technology's real time data system
NASA Technical Reports Server (NTRS)
Voglewede, Steven D.
1994-01-01
The Single Stage Rocket Technology (SSRT) Delta Clipper Experimental (DC-X) Program is a United States Air Force Ballistic Missile Defense Organization (BMDO) rapid prototyping initiative that is currently demonstrating technology readiness for reusable suborbital rockets. The McDonnell Douglas DC-X rocket performed technology demonstrations at the U.S. Army White Sands Missile Range in New Mexico from April-October in 1993. The DC-X Flight Operations Control Center (FOCC) contains the ground control system that is used to monitor and control the DC-X vehicle and its Ground Support Systems (GSS). The FOCC is operated by a flight crew of three operators. Two operators manage the DC-X Flight Systems and one operator is the Ground Systems Manager. A group from McDonnell Douglas Aerospace at KSC developed the DC-X ground control system for the FOCC. This system is known as the Real Time Data System (RTDS). The RTDS is a distributed real time control and monitoring system that utilizes the latest available commercial off-the-shelf computer technology. The RTDS contains front end interfaces for the DC-X RF uplink/downlink and fiber optic interfaces to the GSS equipment. This paper describes the RTDS architecture and FOCC layout. The DC-X applications and ground operations are covered.
Clinical significance of serum decoy receptor 3 levels in patients with systemic sclerosis.
Yamada, Daisuke; Asano, Yoshihide; Takahashi, Takehiro; Masui, Yuri; Aozasa, Naohiko; Akamata, Kaname; Noda, Shinji; Tamaki, Zenshiro; Tada, Yayoi; Sugaya, Makoto; Sato, Shinichi; Kadono, Takafumi
2012-01-01
Decoy receptor 3 (DcR3) is associated with autoimmunity and altered angiogenesis in certain pathological conditions. We herein measured serum DcR3 levels in 51 patients with systemic sclerosis (SSc) and 19 healthy controls and evaluated their clinical significance in this disorder. Serum DcR3 levels were significantly higher in diffuse cutaneous SSc (dcSSc) patients than in limited cutaneous SSc patients and in healthy controls. In dcSSc, serum DcR3 levels were significantly elevated in patients with disease duration of ≤6 years compared with healthy controls, but not in those with disease duration of >6 years. Serum DcR3 levels correlated negatively with the percentage of predicted diffusion lung capacity for carbon monoxide and positively with right ventricular systolic pressure. Furthermore, serum DcR3 levels positively correlated with C-reactive protein, erythrocyte sedimentation rate and immunoglobulin G. Collectively, the elevation of serum DcR3 levels is associated with the development of pulmonary arterial hypertension and systemic inflammation in SSc.
Simultaneous DC and three phase output using hybrid converter
NASA Astrophysics Data System (ADS)
Surenderanath, S.; Rathnavel, P.; Prakash, G.; Rayavel, P.
2018-04-01
This Paper introduces new hybrid converter topologies which can supply simultaneously three phase AC as well as DC from a single DC source. The new Hybrid Converter is derived from the single switch controlled Boost converter by replacing the controlled switch with voltage source inverter (VSI). This new hybrid converter has the advantages like reduced number of switches as compared with conventional design having separate converter for supplying three phase AC and DC loads, provide DC and three AC outputs with an increased reliability, resulting from the inherent shoot through protection in the inverter stage. The proposed converter, studied in this paper, is called Boost-Derived Hybrid Converter (BDHC) as it is obtained from the conventional boost topology. A DSPIC based feedback controller is designed to regulate the DC as well as AC outputs. The proposed Converter can supply DC and AC loads at 95 V and 35 V (line to ground) respectively from a 48 V DC source.
Medeiros, Renan Landau Paiva de; Barra, Walter; Bessa, Iury Valente de; Chaves Filho, João Edgar; Ayres, Florindo Antonio de Cavalho; Neves, Cleonor Crescêncio das
2018-02-01
This paper describes a novel robust decentralized control design methodology for a single inductor multiple output (SIMO) DC-DC converter. Based on a nominal multiple input multiple output (MIMO) plant model and performance requirements, a pairing input-output analysis is performed to select the suitable input to control each output aiming to attenuate the loop coupling. Thus, the plant uncertainty limits are selected and expressed in interval form with parameter values of the plant model. A single inductor dual output (SIDO) DC-DC buck converter board is developed for experimental tests. The experimental results show that the proposed methodology can maintain a desirable performance even in the presence of parametric uncertainties. Furthermore, the performance indexes calculated from experimental data show that the proposed methodology outperforms classical MIMO control techniques. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
Dendritic cells exposed in vitro to TGF-β1 ameliorate experimental autoimmune myasthenia gravis
YARILIN, D; DUAN, R; HUANG, Y-M; XIAO, B-G
2002-01-01
Experimental autoimmune myasthenia gravis (EAMG) is an animal model for human myasthenia gravis (MG), characterized by an autoaggressive T-cell-dependent antibody-mediated immune response directed against the acetylcholine receptor (AChR) of the neuromuscular junction. Dendritic cells (DC) are unique antigen-presenting cells which control T- and B-cell functions and induce immunity or tolerance. Here, we demonstrate that DC exposed to TGF-β1 in vitro mediate protection against EAMG. Freshly prepared DC from spleen of healthy rats were exposed to TGF-β1 in vitro for 48 h, and administered subcutaneously to Lewis rats (2 × 106DC/rat) on day 5 post immunization with AChR in Freund’s complete adjuvant. Control EAMG rats were injected in parallel with untreated DC (naive DC) or PBS. Lewis rats receiving TGF-β1-exposed DC developed very mild symptoms of EAMG without loss of body weight compared with control EAMG rats receiving naive DC or PBS. This effect of TGF-β1-exposed DC was associated with augmented spontaneous and AChR-induced proliferation, IFN-γ and NO production, and decreased levels of anti-AChR antibody-secreting cells. Autologous DC exposed in vitro to TGF-β1 could represent a new opportunity for DC-based immunotherapy of antibody-mediated autoimmune diseases. PMID:11876742
Distributed control system for parallel-connected DC boost converters
Goldsmith, Steven
2017-08-15
The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.
Bifurcation Analysis of a DC-DC Bidirectional Power Converter Operating with Constant Power Loads
NASA Astrophysics Data System (ADS)
Cristiano, Rony; Pagano, Daniel J.; Benadero, Luis; Ponce, Enrique
Direct current (DC) microgrids (MGs) are an emergent option to satisfy new demands for power quality and integration of renewable resources in electrical distribution systems. This work addresses the large-signal stability analysis of a DC-DC bidirectional converter (DBC) connected to a storage device in an islanding MG. This converter is responsible for controlling the balance of power (load demand and generation) under constant power loads (CPLs). In order to control the DC bus voltage through a DBC, we propose a robust sliding mode control (SMC) based on a washout filter. Dynamical systems techniques are exploited to assess the quality of this switching control strategy. In this sense, a bifurcation analysis is performed to study the nonlinear stability of a reduced model of this system. The appearance of different bifurcations when load parameters and control gains are changed is studied in detail. In the specific case of Teixeira Singularity (TS) bifurcation, some experimental results are provided, confirming the mathematical predictions. Both a deeper insight in the dynamic behavior of the controlled system and valuable design criteria are obtained.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-20
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-698] In the Matter of: Certain DC-DC Controllers and Products Containing Same; Notice of Commission Decision Not To Review the Administrative Law... determination is contained in section 337 of the Tariff Act of 1930, as amended (19 U.S.C. 1337), and in section...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-06
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-698] In the Matter of Certain DC-DC Controllers and Products Containing Same; Notice of Commission Decision Not to Review the Administrative Law... Tariff Act of 1930, as amended (19 U.S.C. 1337), and in section 210.42 of the Commission's Rules of...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-26
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-698] In the Matter of Certain DC-DC Controllers and Products Containing Same; Notice of Commission Decision Not To Review an Initial Determination..., as amended (19 U.S.C. 1337), and in sections 210.21(b) and 210.42 of the Commission's Rules of...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-26
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-698] In the Matter of Certain DC-DC Controllers and Products Containing Same; Notice of Commission Decision Not To Review an Initial Determination..., as amended (19 U.S.C. 1337), and in sections 210.21(b) and 210.42 of the Commission's Rules of...
Gonzales, Ralph; Corbett, Kitty K; Leeman-Castillo, Bonnie A; Glazner, Judith; Erbacher, Kathleen; Darr, Carol A; Wong, Shale; Maselli, Judith H; Sauaia, Angela; Kafadar, Karen
2005-01-01
Objective To assess the marginal impact of patient education on antibiotic prescribing to children with pharyngitis and adults with acute bronchitis in private office practices. Data Sources/Study Setting Antibiotic prescription rates based on claims data from four managed care organizations in Colorado during baseline (winter 2000) and study (winter 2001) periods. Study Design A nonrandomized controlled trial of a household and office-based patient educational intervention was performed. During both periods, Colorado physicians were mailed antibiotic prescribing profiles and practices guidelines as part of an ongoing quality improvement program. Intervention practices (n=7) were compared with local and distant control practices. Data Collection/Extraction Methods Office visits were extracted by managed care organizations using International Classification of Diseases-9-Clinical Modification codes for acute respiratory tract infections, and merged with pharmacy claims data based on visit and dispensing dates coinciding within 2 days. Principal Findings Adjusted antibiotic prescription rates during baseline and study periods increased from 38 to 39 percent for pediatric pharyngitis at the distant control practices, and decreased from 39 to 37 percent at the local control practices, and from 34 to 30 percent at the intervention practices (p=.18 compared with distant control practices). Adjusted antibiotic prescription rates decreased from 50 to 44 percent for adult bronchitis at the distant control practices, from 55 to 45 percent at the local control practices, and from 60 to 36 percent at the intervention practices (p<.002 and p=.006 compared with distant and local control practices, respectively). Conclusions In office practices, there appears to be little room for improvement in antibiotic prescription rates for children with pharyngitis. In contrast, patient education helps reduce antibiotic use for adults with acute bronchitis beyond that achieved by physician-directed efforts. PMID:15663704
Automatic Camera Control System for a Distant Lecture with Videoing a Normal Classroom.
ERIC Educational Resources Information Center
Suganuma, Akira; Nishigori, Shuichiro
The growth of a communication network technology enables students to take part in a distant lecture. Although many lectures are conducted in universities by using Web contents, normal lectures using a blackboard are still held. The latter style lecture is good for a teacher's dynamic explanation. A way to modify it for a distant lecture is to…
NASA Technical Reports Server (NTRS)
Burns, W. W., III; Wilson, T. G.
1976-01-01
State-plane analysis techniques are employed to study the voltage step up energy storage dc-to-dc converter. Within this framework, an example converter operating under the influence of a constant on time and a constant frequency controller is examined. Qualitative insight gained through this approach is used to develop a conceptual free running control law for the voltage step up converter which can achieve steady state operation in one on/off cycle of control. Digital computer simulation data is presented to illustrate and verify the theoretical discussions presented.
Tsubono, Kenjiro; Thomlinson, Paul; Shealy, C Norman
2009-01-01
Many individuals suffer from various kinds of chronic pain. Some controlled studies on distant healing for chronic pain exist, but no definitive conclusion has been established. To study the effects of distant healing performed by a professional Japanese healer on chronic pain. A double-blind randomized controlled study. Holos University, Fair Grove, Missouri. People suffering from chronic pain (not caused by clear organic diseases or that persists long after a reasonable period of healing following injuries or surgery) were recruited through local radio and newspaper advertising. Subjects were randomly assigned to a treatment group or control group using a double-blind procedure. All subjects met the healer at the initial session at Holos University. At the session, a 20-minute group meditation was performed. The healer went back to Japan after the session and started distant healing only to the treatment group for a 2-month period. All participants were asked to meditate for 20 minutes every day during this 2-month period. The visual analog scale and McGill Pain Questionnaire. A total of 17 subjects were recruited, and 16 subjects completed the study. Comparison of pretreatment and posttreatment visual analog scale indicated a slightly significant effect of distant healing (P=.056). The Present Pain Intensity Scale showed significant improvement in the treatment group compared to the control group (P=.0016). The Pain Rating Index showed improvement in the treatment group, but the difference between both groups was not statistically significant (P=.12).
NASA Technical Reports Server (NTRS)
Heronemus, W.
1973-01-01
An offshore wind power system is described that consists of wind driven electrical dc generators mounted on floating towers in offshore waters. The output from the generators supplies underwater electrolyzer stations in which water is converted into hydrogen and oxygen. The hydrogen is piped to shore for conversion to electricity in fuel cell stations. It is estimated that this system can produce 159 x 10 to the ninth power kilowatt-hours per year. It is concluded that solar energy - and that includes wind energy - is the only way out of the US energy dilemma in the not too distant future.
A novel CARD containing splice-isoform of CIITA regulates nitric oxide synthesis in dendritic cells.
Huang, Dachuan; Lim, Sylvia; Chua, Rong Yuan Ray; Shi, Hong; Ng, Mah Lee; Wong, Siew Heng
2010-03-01
MHC class II expression is controlled mainly at transcriptional level by class II transactivator (CIITA), which is a non-DNA binding coactivator and serves as a master control factor for MHC class II genes expression. Here, we describe the function of a novel splice-isoform of CIITA, DC-expressed caspase inhibitory isoform of CIITA (or DC-CASPIC), and we show that the expression of DCCASPIC in DC is upregulated upon lipopolysaccharides (LPS) induction. DC-CASPIC localizes to mitochondria, and protein-protein interaction study demonstrates that DC-CASPIC interacts with caspases and inhibits its activity in DC. Consistently, DC-CASPIC suppresses caspases-induced degradation of nitric oxide synthase-2 (NOS2) and subsequently promotes the synthesis of nitric oxide (NO). NO is an essential regulatory molecule that modulates the capability of DC in stimulating T cell proliferation/activation in vitro; hence, overexpression of DC-CASPIC in DC enhances this stimulation. Collectively, our findings reveal that DC-CASPIC is a key molecule that regulates caspases activity and NO synthesis in DC.
Robust control of the DC-DC boost converter based on the uncertainty and disturbance estimator
NASA Astrophysics Data System (ADS)
Oucheriah, Said
2017-11-01
In this paper, a robust non-linear controller based on the uncertainty and disturbance estimator (UDE) scheme is successfully developed and implemented for the output voltage regulation of the DC-DC boost converter. System uncertainties, external disturbances and unknown non-linear dynamics are lumped as a signal that is accurately estimated using a low-pass filter and their effects are cancelled by the controller. This methodology forms the basis of the UDE-based controller. A simple procedure is also developed that systematically determines the parameters of the controller to meet certain specifications. Using simulation, the effectiveness of the proposed controller is compared against the sliding-mode control (SMC). Experimental tests also show that the proposed controller is robust to system uncertainties, large input and load perturbations.
Advanced dc motor controller for battery-powered electric vehicles
NASA Technical Reports Server (NTRS)
Belsterling, C. A.
1981-01-01
A motor generation set is connected to run from the dc source and generate a voltage in the traction motor armature circuit that normally opposes the source voltage. The functional feasibility of the concept is demonstrated with tests on a Proof of Principle System. An analog computer simulation is developed, validated with the results of the tests, applied to predict the performance of a full scale Functional Model dc Controller. The results indicate high efficiencies over wide operating ranges and exceptional recovery of regenerated energy. The new machine integrates both motor and generator on a single two bearing shaft. The control strategy produces a controlled bidirectional plus or minus 48 volts dc output from the generator permitting full control of a 96 volt dc traction motor from a 48 volt battery, was designed to control a 20 hp traction motor. The controller weighs 63.5 kg (140 lb.) and has a peak efficiency of 90% in random driving modes and 96% during the SAE J 227a/D driving cycle.
Development, Demonstration, and Control of a Testbed for Multiterminal HVDC System
Li, Yalong; Shi, Xiaojie M.; Liu, Bo; ...
2016-10-21
This paper presents the development of a scaled four-terminal high-voltage direct current (HVDC) testbed, including hardware structure, communication architecture, and different control schemes. The developed testbed is capable of emulating typical operation scenarios including system start-up, power variation, line contingency, and converter station failure. Some unique scenarios are also developed and demonstrated, such as online control mode transition and station re-commission. In particular, a dc line current control is proposed, through the regulation of a converter station at one terminal. By controlling a dc line current to zero, the transmission line can be opened by using relatively low-cost HVDC disconnectsmore » with low current interrupting capability, instead of the more expensive dc circuit breaker. Utilizing the dc line current control, an automatic line current limiting scheme is developed. As a result, when a dc line is overloaded, the line current control will be automatically activated to regulate current within the allowable maximum value.« less
Multilevel-Dc-Bus Inverter For Providing Sinusoidal And Pwm Electrical Machine Voltages
Su, Gui-Jia [Knoxville, TN
2005-11-29
A circuit for controlling an ac machine comprises a full bridge network of commutation switches which are connected to supply current for a corresponding voltage phase to the stator windings, a plurality of diodes, each in parallel connection to a respective one of the commutation switches, a plurality of dc source connections providing a multi-level dc bus for the full bridge network of commutation switches to produce sinusoidal voltages or PWM signals, and a controller connected for control of said dc source connections and said full bridge network of commutation switches to output substantially sinusoidal voltages to the stator windings. With the invention, the number of semiconductor switches is reduced to m+3 for a multi-level dc bus having m levels. A method of machine control is also disclosed.
Bamias, Giorgos; Gizis, Michalis; Delladetsima, Ioanna; Laoudi, Eyfrosyni; Siakavellas, Spyros I; Koutsounas, Ioannis; Kaltsa, Garyfallia; Vlachogiannakos, John; Vafiadis-Zouboulis, Irene; Daikos, George L; Papatheodoridis, George V; Ladas, Spiros D
2016-01-01
Background. Decoy-receptor 3 (DcR3) exerts antiapoptotic and immunomodulatory function and is overexpressed in neoplastic and inflammatory conditions. Serum DcR3 (sDcR3) levels during the chronic hepatitis/cirrhosis/hepatocellular carcinoma (HCC) sequence have not been explored. Objective. To assess the levels and significance of sDcR3 protein in various stages of chronic liver disease. Methods. We compared sDcR3 levels between healthy controls and patients with chronic viral hepatitis (CVH), decompensated cirrhosis (DC), and HCC. Correlations between sDcR3 levels and various patient- and disease-related factors were analyzed. Results. sDcR3 levels were significantly higher in patients with CVH than in controls (P < 0.01). sDcR3 levels were elevated in DC and HCC, being significantly higher compared not only to controls (P < 0.001 for both) but to CVH patients as well (P < 0.001 for both). In addition, DcR3 protein was detected in large quantities in the ascitic fluid of cirrhotics. In patients with CVH, sDcR3 significantly correlated to fibrosis severity, as estimated by Ishak score (P = 0.019) or by liver stiffness measured with elastography (Spearman r = 0.698, P < 0.001). In cirrhotic patients, significant positive correlations were observed between sDcR3 levels and markers of severity of hepatic impairment, including MELD score (r = 0.653, P < 0.001). Conclusions. Circulating levels of DcR3 are elevated during chronic liver disease and correlate with severity of liver damage. sDcR3 may serve as marker for liver fibrosis severity and progression to end-stage liver disease.
Ciaramella, Antonio; Salani, Francesca; Bizzoni, Federica; Pontieri, Francesco E; Stefani, Alessandro; Pierantozzi, Mariangela; Assogna, Francesca; Caltagirone, Carlo; Spalletta, Gianfranco; Bossù, Paola
2013-01-01
The role of inflammation in Parkinson's Disease (PD) is well appreciated, but its underlying mechanisms are still unclear. Our objective was to determine whether dendritic cells (DC), a unique type of migratory immune cells that regulate immunological response and inflammation have an impact on PD. In a case-control study including 80 PD patients and 80 age- and gender-matched healthy control subjects, the two main blood subsets of plasmacytoid and myeloid DC were defined by flow cytometry analysis. Clinical evaluation of subjects consisting of cognition and depression assessment was performed using the Mini Mental State Examination and the Beck Depression Inventory. The severity of motor symptoms was measured using the Unified Parkinson's Disease Rating Scale-Part III. Comparison between patient and control DC measures and their relationships with clinical assessments were evaluated.The following main results were obtained: 1) the level of circulating DC (mainly the myeloid subset) was significantly reduced in PD patients in comparison with healthy controls; 2) after controlling for depressive and cognitive characteristics, the frequency of myeloid DC was confirmed as one of the independent determinants of PD; 3) the number of both myeloid and plasmacytoid DC was negatively associated with motor symptom severity. Overall, the decline of blood DC, perhaps due to the recruitment of immune cells to the site of disease-specific lesions, can be considered a clue of the immune alteration that characterizes PD, suggesting innovative exploitations of DC monitoring as a clinically significant tool for PD treatment. Indeed, this study suggests that reduced peripheral blood DC are a pathologically-relevant factor of PD and also displays the urgency to better understand DC role in PD for unraveling the immune system contribution to disease progression and thus favoring the development of innovative therapies ideally based on immunomodulation.
Digital phase-locked loop speed control for a brushless dc motor
NASA Astrophysics Data System (ADS)
Wise, M. G.
1985-06-01
Speed control of d.c. motors by phase-locked loops (PLL) is becoming increasingly popular. Primary interest has been in employing PLL for constant speed control. This thesis investigates the theory and techniques of digital PLL to speed control of a brushless d.c. motor with a variable speed of operation. Addition of logic controlled count enable/disable to a synchronous up/down counter, used as a phase-frequency detector, is shown to improve the performance of previously proposed PLL control schemes.
Multiple high voltage output DC-to-DC power converter
NASA Technical Reports Server (NTRS)
Cronin, Donald L. (Inventor); Farber, Bertrand F. (Inventor); Gehm, Hartmut K. (Inventor); Goldin, Daniel S. (Inventor)
1977-01-01
Disclosed is a multiple output DC-to-DC converter. The DC input power is filtered and passed through a chopper preregulator. The chopper output is then passed through a current source inverter controlled by a squarewave generator. The resultant AC is passed through the primary winding of a transformer, with high voltages induced in a plurality of secondary windings. The high voltage secondary outputs are each solid-state rectified for passage to individual output loads. Multiple feedback loops control the operation of the chopper preregulator, one being responsive to the current through the primary winding and another responsive to the DC voltage level at a selected output.
Comparison of control structures for a bidirectional high-frequency dc-dc converter
NASA Astrophysics Data System (ADS)
Himmelstoss, Felix A.; Kolar, Johann W.; Zach, Franz C.
1989-08-01
A system for dc-dc power conversion based on a buck-boost converter topology is presented. It makes power flow in both directions possible. The possibility of bidirectional power flow is useful for certain applications, such as uninterruptable power supplies. Starting from a structural diagram the transfer function of the system is derived. The controller for the converter is then designed. It is made up of a simple voltage controller, a voltage controller with an inner loop current controller (cascade control) and with two kinds of state space control. The transfer functions of the different system parts are derived and dimensioning guidelines for the controller sections are presented. The closed loop behavior of the bidirectional converter for the different control structures is analyzed based on simulation using duty cycle averaging. Bodediagrams and step responses are shown.
NASA Astrophysics Data System (ADS)
Banerjee, Bibaswan
In power electronic basedmicrogrids, the computational requirements needed to implement an optimized online control strategy can be prohibitive. The work presented in this dissertation proposes a generalized method of derivation of geometric manifolds in a dc microgrid that is based on the a-priori computation of the optimal reactions and trajectories for classes of events in a dc microgrid. The proposed states are the stored energies in all the energy storage elements of the dc microgrid and power flowing into them. It is anticipated that calculating a large enough set of dissimilar transient scenarios will also span many scenarios not specifically used to develop the surface. These geometric manifolds will then be used as reference surfaces in any type of controller, such as a sliding mode hysteretic controller. The presence of switched power converters in microgrids involve different control actions for different system events. The control of the switch states of the converters is essential for steady state and transient operations. A digital memory look-up based controller that uses a hysteretic sliding mode control strategy is an effective technique to generate the proper switch states for the converters. An example dcmicrogrid with three dc-dc boost converters and resistive loads is considered for this work. The geometric manifolds are successfully generated for transient events, such as step changes in the loads and the sources. The surfaces corresponding to a specific case of step change in the loads are then used as reference surfaces in an EEPROM for experimentally validating the control strategy. The required switch states corresponding to this specific transient scenario are programmed in the EEPROM as a memory table. This controls the switching of the dc-dc boost converters and drives the system states to the reference manifold. In this work, it is shown that this strategy effectively controls the system for a transient condition such as step changes in the loads for the example case.
NASA Astrophysics Data System (ADS)
Park, Sangsoo; Miura, Yushi; Ise, Toshifumi
This paper proposes an intelligent control for the distributed flexible network photovoltaic system using autonomous control and agent. The distributed flexible network photovoltaic system is composed of a secondary battery bank and a number of subsystems which have a solar array, a dc/dc converter and a load. The control mode of dc/dc converter can be selected based on local information by autonomous control. However, if only autonomous control using local information is applied, there are some problems associated with several cases such as voltage drop on long power lines. To overcome these problems, the authors propose introducing agents to improve control characteristics. The autonomous control with agents is called as intelligent control in this paper. The intelligent control scheme that employs the communication between agents is applied for the model system and proved with simulation using PSCAD/EMTDC.
Application of digital control techniques for satellite medium power DC-DC converters
NASA Astrophysics Data System (ADS)
Skup, Konrad R.; Grudzinski, Pawel; Nowosielski, Witold; Orleanski, Piotr; Wawrzaszek, Roman
2010-09-01
The objective of this paper is to present a work concerning a digital control loop system for satellite medium power DC-DC converters that is done in Space Research Centre. The whole control process of a described power converter bases on a high speed digital signal processing. The paper presents a development of a FPGA digital controller for voltage mode stabilization that was implemented using VHDL. The described controllers are a classical digital PID controller and a bang-bang controller. The used converter for testing is a simple model of 5-20 W, 200 kHz buck power converter. A high resolution digital PWM approach is presented. Additionally a simple and effective solution of filtering of an analog-to-digital converter output is presented.
Analysis and Design of Bridgeless Switched Mode Power Supply for Computers
NASA Astrophysics Data System (ADS)
Singh, S.; Bhuvaneswari, G.; Singh, B.
2014-09-01
Switched mode power supplies (SMPSs) used in computers need multiple isolated and stiffly regulated output dc voltages with different current ratings. These isolated multiple output dc voltages are obtained by using a multi-winding high frequency transformer (HFT). A half-bridge dc-dc converter is used here for obtaining different isolated and well regulated dc voltages. In the front end, non-isolated Single Ended Primary Inductance Converters (SEPICs) are added to improve the power quality in terms of low input current harmonics and high power factor (PF). Two non-isolated SEPICs are connected in a way to completely eliminate the need of single-phase diode-bridge rectifier at the front end. Output dc voltages at both the non-isolated and isolated stages are controlled and regulated separately for power quality improvement. A voltage mode control approach is used in the non-isolated SEPIC stage for simple and effective control whereas average current control is used in the second isolated stage.
Mählmann, K; Hamza, E; Marti, E; Dolf, G; Klukowska, J; Gerber, V; Koch, C
2014-12-01
Recent studies suggest that regulatory T cells (Tregs) are associated with disease severity and progression in papilloma virus induced neoplasia. Bovine papilloma virus (BPV) is recognised as the most important aetiological factor in equine sarcoid (ES) disease. The aim of this study was to compare expression levels of Treg markers and associated cytokines in tissue samples of ES-affected equids with skin samples of healthy control horses. Eleven ES-affected, and 12 healthy horses were included in the study. Expression levels of forkhead box protein 3 (FOXP3), interleukin 10 (IL10), interleukin 4 (IL4) and interferon gamma (IFNG) mRNA in lesional and tumour-distant samples from ES-affected horses, as well as in dermal samples of healthy control horses were measured using quantitative reverse transcription polymerase chain reaction (PCR). Expression levels were compared between lesional and tumour-distant as well as between tumour-distant and control samples. Furthermore, BPV-1 E5 DNA in samples of ES-affected horses was quantified using quantitative PCR, and possible associations of viral load, disease severity and gene expression levels were evaluated. Expression levels of FOXP3, IL10 and IFNG mRNA and BPV-1 E5 copy numbers were significantly increased in lesional compared to tumour-distant samples. There was no difference in FOXP3 and cytokine expression in tumour-distant samples from ES- compared with control horses. In tumour-distant samples viral load was positively correlated with IL10 expression and severity score. The increased expression of Treg markers in tumour-associated tissues of ES-affected equids indicates a local, Treg-induced immune suppression. Copyright © 2014 Elsevier Ltd. All rights reserved.
Maklad, Ahmed Marzouk; Bayoumi, Yasser; Senosy Hassan, Mohamed Abdalazez; Elawadi, AbuSaleh A; AlHussain, Hussain; Elyamany, Ashraf; Aldhahri, Saleh F; Al-Qahtani, Khalid Hussain; AlQahtani, Mubarak; Tunio, Mutahir A
2016-01-01
We aimed to investigate the patterns of failure (locoregional and distant metastasis), associated factors, and treatment outcomes in nasopharyngeal carcinoma patients treated with intensity-modulated radiation therapy (IMRT) combined with chemotherapy. From April 2006 to December 2011, 68 nasopharyngeal carcinoma patients were treated with IMRT and chemotherapy at our hospital. Median radiation doses delivered to gross tumor volume and positive neck nodes were 66-70 Gy, 63 Gy to clinical target volume, and 50.4-56 Gy to clinically negative neck. The clinical toxicities, patterns of failures, locoregional control, distant metastasis control, disease-free survival, and overall survival were observed. The median follow-up time was 52.2 months (range: 11-87 months). Epstein-Barr virus infection was positive in 63.2% of patients. Overall disease failure developed in 21 patients, of whom 85.8% belonged to stage III/IV disease. Among these, there were seven locoregional recurrences, three regional recurrences with distant metastases, and eleven distant metastases. The median interval from the date of diagnosis to failure was 26.5 months (range: 16-50 months). Six of ten (60%) locoregional recurrences were treated with reirradiation ± concurrent chemotherapy. The 5-year locoregional control, distant metastasis control, disease-free survival, and overall survival rates of whole cohort were 81.1%, 74.3%, 60.1%, and 73.4%, respectively. Cox regression analyses revealed that neoadjuvant chemotherapy, age, and Epstein-Barr virus were independent predictors for disease-free survival. Neoadjuvant chemotherapy followed by IMRT with or without chemotherapy improves the long-term survival of Saudi patients with nasopharyngeal carcinoma. Distant metastasis was the main pattern of treatment failure. Neoadjuvant chemotherapy, age, and Epstein-Barr virus status before IMRT were important independent prognostic factors.
AC/DC current ratio in a current superimposition variable flux reluctance machine
NASA Astrophysics Data System (ADS)
Kohara, Akira; Hirata, Katsuhiro; Niguchi, Noboru; Takahara, Kazuaki
2018-05-01
We have proposed a current superimposition variable flux reluctance machine for traction motors. The torque-speed characteristics of this machine can be controlled by increasing or decreasing the DC current. In this paper, we discuss an AC/DC current ratio in the current superimposition variable flux reluctance machine. The structure and control method are described, and the characteristics are computed using FEA in several AC/DC ratios.
Pulse Width Modulator Controller Design for a Brushless DC Motor Position Servo.
1987-06-01
C. POWER CONDITIONER SIMULATION Accurate modeling of power conditioning and commutation in brushless dc motors requires explicit definition of the...Study of a Brushless DC Motor Power Conditioner for a Cruise Missile Fin Control Actuator, Master’s Thesis, Naval Postgraduate School, Monterey, Ca...DESIGN FOR A BRUSHLESS DC MOTOR POSITION SERVO by Vincent S. Rossitto June 1987 Thesis Advisor: Alex Gerba, Jr. Approved for public release
Modeling and control of fuel cell based distributed generation systems
NASA Astrophysics Data System (ADS)
Jung, Jin Woo
This dissertation presents circuit models and control algorithms of fuel cell based distributed generation systems (DGS) for two DGS topologies. In the first topology, each DGS unit utilizes a battery in parallel to the fuel cell in a standalone AC power plant and a grid-interconnection. In the second topology, a Z-source converter, which employs both the L and C passive components and shoot-through zero vectors instead of the conventional DC/DC boost power converter in order to step up the DC-link voltage, is adopted for a standalone AC power supply. In Topology 1, two applications are studied: a standalone power generation (Single DGS Unit and Two DGS Units) and a grid-interconnection. First, dynamic model of the fuel cell is given based on electrochemical process. Second, two full-bridge DC to DC converters are adopted and their controllers are designed: an unidirectional full-bridge DC to DC boost converter for the fuel cell and a bidirectional full-bridge DC to DC buck/boost converter for the battery. Third, for a three-phase DC to AC inverter without or with a Delta/Y transformer, a discrete-time state space circuit model is given and two discrete-time feedback controllers are designed: voltage controller in the outer loop and current controller in the inner loop. And last, for load sharing of two DGS units and power flow control of two DGS units or the DGS connected to the grid, real and reactive power controllers are proposed. Particularly, for the grid-connected DGS application, a synchronization issue between an islanding mode and a paralleling mode to the grid is investigated, and two case studies are performed. To demonstrate the proposed circuit models and control strategies, simulation test-beds using Matlab/Simulink are constructed for each configuration of the fuel cell based DGS with a three-phase AC 120 V (L-N)/60 Hz/50 kVA and various simulation results are presented. In Topology 2, this dissertation presents system modeling, modified space vector PWM implementation (MSVPWM) and design of a closed-loop controller of the Z-source converter which utilizes L and C components and shoot-through zero vectors for the standalone AC power generation. The fuel cell system is modeled by an electrical R-C circuit in order to include slow dynamics of the fuel cells and a voltage-current characteristic of a cell is also considered. A discrete-time state space model is derived to implement digital control and a space vector pulse-width modulation (SVPWM) technique is modified to realize the shoot-through zero vectors that boost the DC-link voltage. Also, three discrete-time feedback controllers are designed: a discrete-time optimal voltage controller, a discrete-time sliding mode current controller, and a discrete-time PI DC-link voltage controller. Furthermore, an asymptotic observer is used to reduce the number of sensors and enhance the reliability of the system. To demonstrate the analyzed circuit model and proposed control strategy, various simulation results using Matlab/Simulink are presented under both light/heavy loads and linear/nonlinear loads for a three-phase AC 208 V (L-L)/60 Hz/10 kVA.
PSO Based PI Controller Design for a Solar Charger System
Yau, Her-Terng; Lin, Chih-Jer; Liang, Qin-Cheng
2013-01-01
Due to global energy crisis and severe environmental pollution, the photovoltaic (PV) system has become one of the most important renewable energy sources. Many previous studies on solar charger integrated system only focus on load charge control or switching Maximum Power Point Tracking (MPPT) and charge control modes. This study used two-stage system, which allows the overall portable solar energy charging system to implement MPPT and optimal charge control of Li-ion battery simultaneously. First, this study designs a DC/DC boost converter of solar power generation, which uses variable step size incremental conductance method (VSINC) to enable the solar cell to track the maximum power point at any time. The voltage was exported from the DC/DC boost converter to the DC/DC buck converter, so that the voltage dropped to proper voltage for charging the battery. The charging system uses constant current/constant voltage (CC/CV) method to charge the lithium battery. In order to obtain the optimum PI charge controller parameters, this study used intelligent algorithm to determine the optimum parameters. According to the simulation and experimental results, the control parameters resulted from PSO have better performance than genetic algorithms (GAs). PMID:23766713
PSO based PI controller design for a solar charger system.
Yau, Her-Terng; Lin, Chih-Jer; Liang, Qin-Cheng
2013-01-01
Due to global energy crisis and severe environmental pollution, the photovoltaic (PV) system has become one of the most important renewable energy sources. Many previous studies on solar charger integrated system only focus on load charge control or switching Maximum Power Point Tracking (MPPT) and charge control modes. This study used two-stage system, which allows the overall portable solar energy charging system to implement MPPT and optimal charge control of Li-ion battery simultaneously. First, this study designs a DC/DC boost converter of solar power generation, which uses variable step size incremental conductance method (VSINC) to enable the solar cell to track the maximum power point at any time. The voltage was exported from the DC/DC boost converter to the DC/DC buck converter, so that the voltage dropped to proper voltage for charging the battery. The charging system uses constant current/constant voltage (CC/CV) method to charge the lithium battery. In order to obtain the optimum PI charge controller parameters, this study used intelligent algorithm to determine the optimum parameters. According to the simulation and experimental results, the control parameters resulted from PSO have better performance than genetic algorithms (GAs).
Chen, Kai; Chen, Zhe; Sun, Zhigang; Zhang, Zhuqing; Ding, Dongbing; Ren, Shuangyi; Zuo, Yunfei
2014-01-01
Background Colon cancer has always been diagnosed at a late stage, which is associated with poor prognosis. The currently used serum tumor markers CEA and CA19-9 display low sensitivity and specificity and may not have diagnostic value in early stage colon cancer. Thus, there is an urgent need to identify novel serum biomarkers for use in the early detection of colon cancer. Methods In this study, the expression of DC-SIGN and DC-SIGNR in serum was detected by enzyme-linked immunosorbent assay (ELISA). DC-SIGN and DC-SIGNR expression was detected in cancer tissues by immunohistochemistry (IHC). Results The level of sDC-SIGN was lower in patients than in the healthy controls, while the level of sDC-SIGNR in patients was higher than in the healthy controls. Both sDC-SIGN and sDC-SIGNR had diagnostic significances for cancer patients, and the combined diagnosis of these two markers was higher than both of them alone. Furthermore, there were significant differences between both sDC-SIGN and sDC-SIGNR in stage I/II patients and the healthy controls. Moreover, high sDC-SIGN level was accompanied with the long survival time. Additionally, DC-SIGNR was negative in the cancer foci and matched normal colon tissues but was weakly positive between the cancer foci. DC-SIGN staining was faint in matched normal colon tissues, strong in the tumor stroma and the invasive margin of colon cancer tissues, and negatively correlated with the sDC-SIGN level in serum from the same patient. Interestingly, the percent survival of patients with a DC-SIGN mean density of>0.001219 (the upper 95% confidence interval of matched normal colon tissues) was higher than for all other patients. Conclusion DC-SIGN and DC-SIGNR are blood-based molecular markers that can potentially be used for the diagnosis of early stage patients. Moreover, expression of DC-SIGN in serum and cancer tissues may affect the survival time for colon cancer patients. PMID:25504222
Kilburn, Jeremy M; Lucas, John T; Soike, Michael H; Ayala-Peacock, Diandra N; Blackstock, Arthur W; Hinson, William H; Munley, Michael T; Petty, William J; Urbanic, James J
2016-01-23
We hypothesized that omission of clinical target volumes (CTV) in lung cancer radiotherapy would not compromise control by determining retrospectively if the addition of a CTV would encompass the site of failure. Stage II-III patients were treated from 2009-2012 with daily cone-beam imaging and a 5 mm planning target volume (PTV) without a CTV. PTVs were expanded 1 cm and termed CTVretro. Recurrences were scored as 1) within the PTV, 2) within CTVretro, or 3) outside the PTV. Locoregional control (LRC), distant control (DC), progression-free survival (PFS), and overall survival (OS) were estimated. Among 110 patients, Stage IIIA 57%, IIIB 32%, IIA 4%, and IIB 7%. Eighty-six percent of Stage III patients received chemotherapy. Median dose was 70 Gy (45-74 Gy) and fraction size ranged from 1.5-2.7 Gy. Median follow-up was 12 months, median OS was 22 months (95% CI 19-30 months), and LRC at two years was 69%. Fourteen local and eight regional events were scored with two CTVretro failures equating to a two-year CTV failure-free survival of 98%. Omission of a 1 cm CTV expansion appears feasible based on only two events among 110 patients and should be considered in radiation planning.
Phenotype and function of nasal dendritic cells
Lee, Haekyung; Ruane, Darren; Law, Kenneth; Ho, Yan; Garg, Aakash; Rahman, Adeeb; Esterházy, Daria; Cheong, Cheolho; Goljo, Erden; Sikora, Andrew G.; Mucida, Daniel; Chen, Benjamin; Govindraj, Satish; Breton, Gaëlle; Mehandru, Saurabh
2015-01-01
Intranasal vaccination generates immunity across local, regional and distant sites. However, nasal dendritic cells (DC), pivotal for the induction of intranasal vaccine- induced immune responses, have not been studied in detail. Here, using a variety of parameters, we define nasal DCs in mice and humans. Distinct subsets of “classical” DCs, dependent on the transcription factor zbtb46 were identified in the murine nose. The murine nasal DCs were FLT3 ligand-responsive and displayed unique phenotypic and functional characteristics including the ability to present antigen, induce an allogeneic T cell response and migrate in response to LPS or live bacterial pathogens. Importantly, in a cohort of human volunteers, BDCA-1+ DCs were observed to be the dominant nasal DC population at steady state. During chronic inflammation, the frequency of both BDCA-1+ and BDCA-3hi DCs was reduced in the nasal tissue, associating the loss of these immune sentinels with chronic nasal inflammation. The present study is the first detailed description of the phenotypic, ontogenetic and functional properties of nasal DCs and will inform the design of preventative immunization strategies as well as therapeutic modalities against chronic rhinosinusitis. PMID:25669151
DC to DC power converters and methods of controlling the same
Steigerwald, Robert Louis; Elasser, Ahmed; Sabate, Juan Antonio; Todorovic, Maja Harfman; Agamy, Mohammed
2012-12-11
A power generation system configured to provide direct current (DC) power to a DC link is described. The system includes a first power generation unit configured to output DC power. The system also includes a first DC to DC converter comprising an input section and an output section. The output section of the first DC to DC converter is coupled in series with the first power generation unit. The first DC to DC converter is configured to process a first portion of the DC power output by the first power generation unit and to provide an unprocessed second portion of the DC power output of the first power generation unit to the output section.
Sliding mode controller with modified sliding function for DC-DC Buck Converter.
Naik, B B; Mehta, A J
2017-09-01
This article presents design of Sliding Mode Controller with proportional integral type sliding function for DC-DC Buck Converter for the controlled power supply. The converter with conventional sliding mode controller results in a steady state error in load voltage. The proposed modified sliding function improves the steady state and dynamic performance of the Convertor and facilitates better choices of controller tuning parameters. The conditions for existence of sliding modes for proposed control scheme are derived. The stability of the closed loop system with proposed sliding mode control is proved and improvement in steady state performance is exemplified. The idea of adaptive tuning for the proposed controller to compensate load variations is outlined. The comparative study of conventional and proposed control strategy is presented. The efficacy of the proposed strategy is endowed by the simulation and experimental results. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Performance of a 14.9-kW laminated-frame dc series motor with chopper controller
NASA Technical Reports Server (NTRS)
Schwab, J. R.
1979-01-01
Traction motor using two types of excitation: ripple free dc from a motor generator set for baseline data and chopped dc as supplied by a battery and chopper controller was tested. For the same average values of input voltage and current, the power output was independent of the type of excitation. At the same speeds, motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points less on chopped dc than on ripple-free dc. This illustrates that for chopped waveforms, it is incorrect to calculate input power as the product of average voltage and average current. Locked-rotor torque, no load losses, and magnetic saturation data were so determined.
NASA Technical Reports Server (NTRS)
Wester, Gene W. (Inventor)
1980-01-01
A unity power factor converter capable of effecting either inversion (dc-to-dc) or rectification (ac-to-dc), and capable of providing bilateral power control from a DC source (or load) through an AC transmission line to a DC load (or source) for power flow in either direction, is comprised of comparators for comparing the AC current i with an AC signal i.sub.ref (or its phase inversion) derived from the AC ports to generate control signals to operate a switch control circuit for high speed switching to shape the AC current waveform to a sine waveform, and synchronize it in phase and frequency with the AC voltage at the AC ports, by selectively switching the connections to a series inductor as required to increase or decrease the current i.
Singh, Harmohan N.
2012-06-05
A hybrid power system is comprised of a high energy density element such as a fuel-cell and high power density elements such as a supercapacitor banks. A DC/DC converter electrically connected to the fuel cell and converting the energy level of the energy supplied by the fuel cell. A first switch is electrically connected to the DC/DC converter. First and second supercapacitors are electrically connected to the first switch and a second switch. A controller is connected to the first switch and the second switch, monitoring charge levels of the supercapacitors and controls the switching in response to the charge levels. A load is electrically connected to the second switch. The first switch connects the DC/DC converter to the first supercapacitor when the second switch connects the second supercapacitor to the load. The first switch connects the DC/DC converter to the second supercapacitor when the second switch connects the first supercapacitor to the load.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, Chung-Jan; Head and Neck Oncology Group, Chang Gung Memorial Hospital and Chang Gung University, Taoyuan, Taiwan; Lin, Chien-Yu
2011-11-15
Purpose: The objective of this retrospective study was twofold: (1) to investigate prognostic factors for clinical outcomes in patients with poorly differentiated oral cavity squamous cell carcinoma and (2) to identify specific prognostic subgroups that may help to guide treatment decisions. Methods and Materials: We examined 102 patients with poorly differentiated oral cavity squamous cell carcinoma. All patients were followed for at least 24 months after surgery or until death. The 5-year rates of local control, neck control, distant metastasis, disease-free, disease-specific, and overall survival served as main outcome measures. Results: The 5-year rates were as follows: local control (79%),more » neck control (64%), distant metastases (27%), disease-free survival (48%), disease-specific survival (52%), and overall survival (42%). Multivariable analysis showed that the number of pathologically positive nodes ({>=}4 vs. {<=}3) was a significant predictor of neck control, distant metastasis, and disease-free, disease-specific, and overall survival rates. In addition, the presence of tumor depth of {>=}11 mm (vs. <11 mm) was a significant predictor of distant metastasis, disease-specific survival, and overall survival rates. The combination of the two predictors (26.5%, 27/102) was independently associated with poorer neck control (p = 0.0319), distant metastasis (p < 0.0001), and disease-free (p < 0.0001), disease-specific (p < 0.0001), and overall survival (p < 0.0001) rates. Conclusions: In patients with poorly differentiated oral cavity squamous cell carcinoma, the presence of at least 4 pathologically positive lymph nodes and of a pathological tumor depth {>=}11 mm identifies a subset of subjects with poor clinical outcomes. Patients carrying both risk factors are suitable candidates for the development of novel therapeutic approaches.« less
NASA Astrophysics Data System (ADS)
Abe, Takahiro; Tan, Nadia Mei Lin; Akagi, Hirofumi
This paper presents an experimental discussion on a 6-kW, full-bridge, zero-voltage switching bidirectional isolated dc/dc converter for a 53.2-V, 2-kWh Li-ion battery energy storage system. The combination of high-frequency switching devices, 600-V/200-A IGBTs and 100-V/500-A MOSFETs with a high-frequency transformer reduces the weight and physical size of the bidirectional isolated dc/dc converter. The dc voltage on the high-voltage side of the converter is controlled in a range of 300V to 355V as the battery voltage on the low-voltage side varies from 50V to 59V. Experimental verification of bidirectional power flow into (battery charging) or out of (battery discharging) the Li-ion battery bank is also presented. The maximal efficiency of the dc/dc converter is measured to be 98.1% during charging and 98.2% during discharging, excluding the gate drive loss and control circuit loss.
NASA Astrophysics Data System (ADS)
Calderone, Luigi; Pinola, Licia; Varoli, Vincenzo
1992-04-01
The paper describes an analytical procedure to optimize the feed-forward compensation for any PWM dc/dc converters. The aims of achieving zero dc audiosusceptibility was found to be possible for the buck, buck-boost, Cuk, and SEPIC cells; for the boost converter, however, only nonoptimal compensation is feasible. Rules for the design of PWM controllers and procedures for the evaluation of the hardware-introduced errors are discussed. A PWM controller implementing the optimal feed-forward compensation for buck-boost, Cuk, and SEPIC cells is described and fully experimentally characterized.
Hybrid electric vehicle power management system
Bissontz, Jay E.
2015-08-25
Level voltage levels/states of charge are maintained among a plurality of high voltage DC electrical storage devices/traction battery packs that are arrayed in series to support operation of a hybrid electric vehicle drive train. Each high voltage DC electrical storage device supports a high voltage power bus, to which at least one controllable load is connected, and at least a first lower voltage level electrical distribution system. The rate of power transfer from the high voltage DC electrical storage devices to the at least first lower voltage electrical distribution system is controlled by DC-DC converters.
Digital Control Technologies for Modular DC-DC Converters
NASA Technical Reports Server (NTRS)
Button, Robert M.; Kascak, Peter E.; Lebron-Velilla, Ramon
2002-01-01
Recent trends in aerospace Power Management and Distribution (PMAD) systems focus on using commercial off-the-shelf (COTS) components as standard building blocks. This move to more modular designs has been driven by a desire to reduce costs and development times, but is also due to the impressive power density and efficiency numbers achieved by today's commercial DC-DC converters. However, the PMAD designer quickly learns of the hidden "costs" of using COTS converters. The most significant cost is the required addition of external input filters to meet strict electromagnetic interference (MIAMI) requirements for space systems. In fact, the high power density numbers achieved by the commercial manufacturers are greatly due to the lack of necessary input filters included in the COTS module. The NASA Glenn Research Center is currently pursuing a digital control technology that addresses this problem with modular DC-DC converters. This paper presents the digital control technologies that have been developed to greatly reduce the input filter requirements for paralleled, modular DC-DC converters. Initial test result show that the input filter's inductor size was reduced by 75 percent, and the capacitor size was reduced by 94 percent while maintaining the same power quality specifications.
NASA Technical Reports Server (NTRS)
Toon, Owen B.; Maring, Hal; Dibb, Jack; Ferrare, Richard A.; Jacob, Daniel J.; Jensen, Eric J.; Luo, Z. Johnny; Mace, Gerald G.; Pan, Laura L.; Pfister, Leonhard;
2016-01-01
The Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) field mission based at Ellington Field, Texas, during August and September 2013 employed the most comprehensive airborne payload to date to investigate atmospheric composition over North America. The NASA ER-2, DC-8, and SPEC Inc. Learjet flew 57 science flights from the surface to 20 km. The ER-2 employed seven remote sensing instruments as a satellite surrogate and eight in situ instruments. The DC-8 employed 23 in situ and five remote sensing instruments for radiation, chemistry, and microphysics. The Learjet used 11 instruments to explore cloud microphysics. SEAC4RS launched numerous balloons, augmented Aerosol RObotic NETwork, and collaborated with many existing ground measurement sites. Flights investigating convection included close coordination of all three aircraft. Coordinated DC-8 and ER-2 flights investigated the optical properties of aerosols, the influence of aerosols on clouds, and the performance of new instruments for satellite measurements of clouds and aerosols. ER-2 sorties sampled stratospheric injections of water vapor and other chemicals by local and distant convection. DC-8 flights studied seasonally evolving chemistry in the Southeastern U.S., atmospheric chemistry with lower emissions of NOx and SO2 than in previous decades, isoprene chemistry under high and low NOx conditions at different locations, organic aerosols, air pollution near Houston and in petroleum fields, smoke from wildfires in western forests and from agricultural fires in the Mississippi Valley, and the ways in which the chemistry in the boundary layer and the upper troposphere were influenced by vertical transport in convective clouds.
Hardware Evolution of Analog Speed Controllers for a DC Motor
NASA Technical Reports Server (NTRS)
Gwaltney, David A.; Ferguson, Michael I.
2003-01-01
This viewgraph presentation provides information on the design of analog speed controllers for DC motors on aerospace systems. The presentation includes an overview of controller evolution, evolvable controller configuration, an emphasis on proportion integral (PI) controllers, schematic diagrams, and experimental results.
Research on Control System of Three - phase Brushless DC Motor for Electric Vehicle
NASA Astrophysics Data System (ADS)
Wang, Zhiwei; Jin, Hai; Guo, Jie; Su, Jie; Wang, Miao
2017-12-01
In order to study the three-phase brushless motor control system of electric vehicle, Freescale9S12XS128 chip is used as the control core, and the power MOSFET is used as the inverter device. The software is compiled by Codewarrior software. The speed control link adopts open-loop control, and the control chip collects the external sensor signal voltage Change control PWM signal output control three-phase brushless DC motor speed. The whole system consists of Hall position detection module, current detection module, power drive module and voltage detection module. The basic functions of three-phase brushless DC motor drive control are realized.
DC Motor control using motor-generator set with controlled generator field
Belsterling, Charles A.; Stone, John
1982-01-01
A d.c. generator is connected in series opposed to the polarity of a d.c. power source supplying a d.c. drive motor. The generator is part of a motor-generator set, the motor of which is supplied from the power source connected to the motor. A generator field control means varies the field produced by at least one of the generator windings in order to change the effective voltage output. When the generator voltage is exactly equal to the d.c. voltage supply, no voltage is applied across the drive motor. As the field of the generator is reduced, the drive motor is supplied greater voltage until the full voltage of the d.c. power source is supplied when the generator has zero field applied. Additional voltage may be applied across the drive motor by reversing and increasing the reversed field on the generator. The drive motor may be reversed in direction from standstill by increasing the generator field so that a reverse voltage is applied across the d.c. motor.
Modelling and control of solid oxide fuel cell generation system in microgrid
NASA Astrophysics Data System (ADS)
Zhou, Niancheng; Li, Chunyan; Sun, Fangqing; Wang, Qianggang
2017-11-01
Compared with other kinds of fuel cells, solid oxide fuel cell (SOFC) has been widely used in microgrids because of its higher efficiency and longer operation life. The weakness of SOFC lies in its slow response speed when grid disturbance occurs. This paper presents a control strategy that can promote the response speed and limit the fault current impulse for SOFC systems integrated into microgrids. First, the hysteretic control of the bidirectional DC-DC converter, which joins the SOFC and DC bus together, is explored. In addition, an improved droop control with limited current protection is applied in the DC-AC inverter, and the active synchronization control is applied to ensure a smooth transition of the microgrid between the grid-connected mode and the islanded mode. To validate the effectiveness of this control strategy, the control model was built and simulated in PSCAD/EMTDC.
Controller for computer control of brushless dc motors. [automobile engines
NASA Technical Reports Server (NTRS)
Hieda, L. S. (Inventor)
1981-01-01
A motor speed and torque controller for brushless d.c. motors provides an unusually smooth torque control arrangement. The controller provides a means for controlling a current waveform in each winding of a brushless dc motor by synchronization of an excitation pulse train from a programmable oscillator. Sensing of torque for synchronization is provided by a light beam chopper mounted on the motor rotor shaft. Speed and duty cycle are independently controlled by controlling the frequency and pulse width output of the programmable oscillator. A means is also provided so that current transitions from one motor winding to another is effected without abrupt changes in output torque.
Anti-apoptosis Effect of Decoy Receptor 3 in Cholangiocarcinoma Cell Line TFK-1
Xu, Ying-Chen; Cui, Jing; Zhang, Li-Jun; Zhang, Dong-Xin; Xing, Bing-Chen; Huang, Xiong-Wei-Ye; Wu, Ji-Xiang; Liang, Chao-Jie; Li, Guang-Ming
2018-01-01
Background: Decoy receptor 3 (DcR3) is a protein with anti-apoptotic effect that belongs to the tumor necrosis factor receptor superfamily. DcR3 is highly expressed in a variety of malignant tumors including cholangiocarcinoma and its expression was found to be related to the clinical stage, the invasion, and the metastasis of the tumor. This in vitro study aimed to investigate the effect of downregulated expression of DcR3 on cell viability, cell apoptosis, and cell cycle in cholangiocarcinoma cell line TFK-1. Methods: Three different cell lines were cultured: human cholangiocarcinoma TFK-1, human biliary epithelial carcinoma HuCCT-1, and human cholangiocarcinoma RBE. The cholangiocarcinoma cell line with the highest expression of DcR3 was selected for further investigation. The expression of DcR3 was silenced/knocked down by transfection with DcR3-siRNA in the selected cell line. Various biological phenotype parameters such as cell viability, apoptosis, and cell cycle were observed. Results: The mRNA and protein levels of DcR3 were measured in the three cell lines, and TFK-1 was selected. After the treatment with DcR3-siRNA for 48 h, DcR3 mRNA and protein expression in the treatment group were 38.45% (P < 0.01) and 48.03% (P < 0.05) of that of the control, respectively. It was found that the cell viability decreased to 61.87% of the control group (P < 0.01) after the downregulation of DcR3 in cholangiocarcinoma cell line TFK-1 by transfection with DcR3-siRNA, while the percentage of apoptotic cells was 2.98 times as compared with the control group (P < 0.05). Compared with the control group the ratio of G0/G1 increased, and the ratio of G2/M decreased in the treatment group. However, the differences were not statistically significant. Conclusions: The effect of DcR3 on the growth and apoptosis of cholangiocarcinoma has been demonstrated. DcR3 is not only a predictive marker for malignant tumor but it is also likely to be a potential target for cancer gene therapy. Further studies should focus on exploring the binding ligand of DcR3, the signaling pathway involved, and the molecular mechanism for the regulation of DcR3 expression in cholangiocarcinoma. PMID:29271385
Anti-apoptosis Effect of Decoy Receptor 3 in Cholangiocarcinoma Cell Line TFK-1.
Xu, Ying-Chen; Cui, Jing; Zhang, Li-Jun; Zhang, Dong-Xin; Xing, Bing-Chen; Huang, Xiong-Wei-Ye; Wu, Ji-Xiang; Liang, Chao-Jie; Li, Guang-Ming
2018-01-05
Decoy receptor 3 (DcR3) is a protein with anti-apoptotic effect that belongs to the tumor necrosis factor receptor superfamily. DcR3 is highly expressed in a variety of malignant tumors including cholangiocarcinoma and its expression was found to be related to the clinical stage, the invasion, and the metastasis of the tumor. This in vitro study aimed to investigate the effect of downregulated expression of DcR3 on cell viability, cell apoptosis, and cell cycle in cholangiocarcinoma cell line TFK-1. Three different cell lines were cultured: human cholangiocarcinoma TFK-1, human biliary epithelial carcinoma HuCCT-1, and human cholangiocarcinoma RBE. The cholangiocarcinoma cell line with the highest expression of DcR3 was selected for further investigation. The expression of DcR3 was silenced/knocked down by transfection with DcR3-siRNA in the selected cell line. Various biological phenotype parameters such as cell viability, apoptosis, and cell cycle were observed. The mRNA and protein levels of DcR3 were measured in the three cell lines, and TFK-1 was selected. After the treatment with DcR3-siRNA for 48 h, DcR3 mRNA and protein expression in the treatment group were 38.45% (P < 0.01) and 48.03% (P < 0.05) of that of the control, respectively. It was found that the cell viability decreased to 61.87% of the control group (P < 0.01) after the downregulation of DcR3 in cholangiocarcinoma cell line TFK-1 by transfection with DcR3-siRNA, while the percentage of apoptotic cells was 2.98 times as compared with the control group (P < 0.05). Compared with the control group the ratio of G0/G1increased, and the ratio of G2/M decreased in the treatment group. However, the differences were not statistically significant. The effect of DcR3 on the growth and apoptosis of cholangiocarcinoma has been demonstrated. DcR3 is not only a predictive marker for malignant tumor but it is also likely to be a potential target for cancer gene therapy. Further studies should focus on exploring the binding ligand of DcR3, the signaling pathway involved, and the molecular mechanism for the regulation of DcR3 expression in cholangiocarcinoma.
Research on MMC-SST Oriented AC/DC Distribution System
NASA Astrophysics Data System (ADS)
Xie, Xifeng; Shi, Hua; Zuo, Jianglin; Zhang, Zhigang
2018-01-01
A modular multilevel converter-solid state transformer (MMC-SST) oriented AC/DC Distribution System is designed. Firstly, the topology structure is introduced, MMC is adopted in the input stage, multiple DC-DC converters are adopted in the isolation stage, and a Three-Phase Four-Leg inverter is adopted in the output stage. Then, the control strategy is analysed. Finally, simulation model and an experimental prototype of MMC-SST are built, simulation and experimental results show that topology and control strategy of MMC-SST are feasible.
Design and implementation of co-operative control strategy for hybrid AC/DC microgrids
NASA Astrophysics Data System (ADS)
Mahmud, Rasel
This thesis is mainly divided in two major sections: 1) Modeling and control of AC microgrid, DC microgrid, Hybrid AC/DC microgrid using distributed co-operative control, and 2) Development of a four bus laboratory prototype of an AC microgrid system. At first, a distributed cooperative control (DCC) for a DC microgrid considering the state-of-charge (SoC) of the batteries in a typical plug-in-electric-vehicle (PEV) is developed. In DC microgrids, this methodology is developed to assist the load sharing amongst the distributed generation units (DGs), according to their ratings with improved voltage regulation. Subsequently, a DCC based control algorithm for AC microgrid is also investigated to improve the performance of AC microgrid in terms of power sharing among the DGs, voltage regulation and frequency deviation. The results validate the advantages of the proposed methodology as compared to traditional droop control of AC microgrid. The DCC-based control methodology for AC microgrid and DC microgrid are further expanded to develop a DCC-based power management algorithm for hybrid AC/DC microgrid. The developed algorithm for hybrid microgrid controls the power flow through the interfacing converter (IC) between the AC and DC microgrids. This will facilitate the power sharing between the DGs according to their power ratings. Moreover, it enables the fixed scheduled power delivery at different operating conditions, while maintaining good voltage regulation and improved frequency profile. The second section provides a detailed explanation and step-by-step design and development of an AC/DC microgrid testbed. Controllers for the three-phase inverters are designed and tested on different generation units along with their corresponding inductor-capacitor-inductor (LCL) filters to eliminate the switching frequency harmonics. Electric power distribution line models are developed to form the microgrid network topology. Voltage and current sensors are placed in the proper positions to achieve a full visibility over the microgrid. A running average filter (RAF) based enhanced phase-locked-loop (EPLL) is designed and implemented to extract frequency and phase angle information. A PLL-based synchronizing scheme is also developed to synchronize the DGs to the microgrid. The developed laboratory prototype runs on dSpace platform for real time data acquisition, communication and controller implementation.
Leptin deficiency in vivo enhances the ability of splenic dendritic cells to activate T cells
Ramirez, Oscar
2014-01-01
Leptin is a pleiotropic adipokine that is critical for regulating food intake and energy expenditure and also participates in functions of the immune system, including those of antigen-presenting cells. Here, we assess the effect of leptin deficiency on the function splenic dendritic cells (sDC). sDC from leptin-deficient mice (Lepob) were evaluated ex vivo for phenotype, ability to respond to inflammatory stimuli, to acquire and process antigens and to activate T cells. The data show that Lepob sDC express activation markers similar to controls and respond similarly to LPS activation or anti-CD40 cross-linking. In addition, antigen acquisition and processing by Lepob sDC was similar to controls. However, Lepob sDC elicited higher production of IFN-γ in mixed lymphocyte reactions and increased production of IL-2 by antigen-specific T-cell hybridoma relative to controls. To assess Lepob sDC activation of T cells in vivo, Lepob and control mice were infected systemically with Mycobacterium avium. Lepob mice were significantly better at neutralizing the infection as measured by splenic bacterial load over time. This was mirrored with an increased percentage of activated T cells in M. avium-infected Lepob mice. Thus, although no changes were detected in sDC phenotype, activation, antigen processing or presentation, these DC surprisingly presented an enhanced ability to activate T cells ex vivo and in vivo. These data demonstrate that leptin can modulate DC function and suggest that leptin may dampen T-cell responsiveness in the physiological setting. PMID:24966213
Buhl, Timo; Legler, Tobias J; Rosenberger, Albert; Schardt, Anke; Schön, Michael P; Haenssle, Holger A
2012-11-01
Availability of large quantities of functionally effective dendritic cells (DC) represents one of the major challenges for immunotherapeutic trials against infectious or malignant diseases. Low numbers or insufficient T-cell activation of DC may result in premature termination of treatment and unsatisfying immune responses in clinical trials. Based on the notion that cryopreservation of monocytes is superior to cryopreservation of immature or mature DC in terms of resulting DC quantity and immuno-stimulatory capacity, we aimed to establish an optimized protocol for the cryopreservation of highly concentrated peripheral blood mononuclear cells (PBMC) for DC-based immunotherapy. Cryopreserved cell preparations were analyzed regarding quantitative recovery, viability, phenotype, and functional properties. In contrast to standard isopropyl alcohol (IPA) freezing, PBMC cryopreservation in an automated controlled-rate freezer (CRF) with subsequent thawing and differentiation resulted in significantly higher cell yields of immature and mature DC. Immature DC yields and total protein content after using CRF were comparable with results obtained with freshly prepared PBMC and exceeded results of standard IPA freezing by approximately 50 %. While differentiation markers, allogeneic T-cell stimulation, viability, and cytokine profiles were similar to DC from standard freezing procedures, DC generated from CRF-cryopreserved PBMC induced a significantly higher antigen-specific IFN-γ release from autologous effector T cells. In summary, automated controlled-rate freezing of highly concentrated PBMC represents an improved method for increasing DC yields and autologous T-cell stimulation.
Micro grid control strategy of DFIG unit based on improved DC grid connected topology
NASA Astrophysics Data System (ADS)
Zongze, Xia; Fei, Xia; Zhixiong, Yang
2017-05-01
Aiming to the application of the DFIG connected to DC-Microgrids, an improved topology for the DFIG connected to DC-Microgrids is taken into account in this thesis. The stator side loses the support of voltage and frequency of AC point of common coupling bus. A novel control method suitable to the stator side converter (SSC) and the rotor side converter (RSC) of the topology is proposed. The independent control of stator voltage and frequency, the decoupled control of power and variable speed constant frequency of DFIG are achieved in the doubly-fed induction generator connected to DC-Microgrids. which can enhance the capacity of active power transmission of DFIG during the voltage variation.
Synthetic Space Vector Modulation
2013-06-01
especially batteries without fancy controls. Inherently, DC machine commutation is environmentally sensitive and maintenance intensive at well as...reliable DC power supplies especially batteries without fancy controls. Inherently, DC machine commutation is environmentally sensitive and maintenance...Drives and Energy Systems, New Delhi, India , 20-23 December, 2010. [12] PIC18F2331/2431/4331/4431 datasheet DS39616B, Microchip Technology Inc
Brushless DC motor control system responsive to control signals generated by a computer or the like
NASA Technical Reports Server (NTRS)
Packard, D. T. (Inventor)
1985-01-01
A control system for a brushless DC motor responsive to digital control signals is disclosed. The motor includes a multiphase wound stator and a permanent magnet rotor. The motor is arranged so that each phase winding, when energized from a DC source, will drive the rotor through a predetermined angular position or step. A commutation signal generator responsive to the shaft position provides a commutation signal for each winding. A programmable control signal generator such as a computer or microprocessor produces individual digital control signals for each phase winding. The control signals and commutation signals associated with each winding are applied to an AND gate for that phase winding. Each gate controls a switch connected in series with the associated phase winding and the DC source so that each phase winding is energized only when the commutation signal and the control signal associated with that phase winding are present. The motor shaft may be advanced one step at a time to a desired position by applying a predetermined number of control signals in the proper sequence to the AND gates and the torque generated by the motor be regulated by applying a separate control signal and each AND gate which is pulse width modulated to control the total time that each switch connects its associated winding to the DC source during each commutation period.
Brushless DC motor control system responsive to control signals generated by a computer or the like
NASA Technical Reports Server (NTRS)
Packard, Douglas T. (Inventor); Schmitt, Donald E. (Inventor)
1987-01-01
A control system for a brushless DC motor responsive to digital control signals is disclosed. The motor includes a multiphase wound stator and a permanent magnet rotor. The rotor is arranged so that each phase winding, when energized from a DC source, will drive the rotor through a predetermined angular position or step. A commutation signal generator responsive to the shaft position provides a commutation signal for each winding. A programmable control signal generator such as a computer or microprocessor produces individual digital control signals for each phase winding. The control signals and commutation signals associated with each winding are applied to an AND gate for that phase winding. Each gate controls a switch connected in series with the associated phase winding and the DC source so that each phase winding is energized only when the commutation signal and the control signal associated with that phase winding are present. The motor shaft may be advanced one step at a time to a desired position by applying a predetermined number of control signals in the proper sequence to the AND gates and the torque generated by the motor may be regulated by applying a separate control signal to each AND gate which is pulse width modulated to control the total time that each switch connects its associated winding to the DC source during each commutation period.
DC motor proportional control system for orthotic devices
NASA Technical Reports Server (NTRS)
Blaise, H. T.; Allen, J. R.
1972-01-01
Multi-channel proportional control system for operation of dc motors for use with externally-powered orthotic arm braces is described. Components of circuitry and principles of operation are described. Schematic diagram of control circuit is provided.
Oğuz, Yüksel; Güney, İrfan; Çalık, Hüseyin
2013-01-01
The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS) operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%. PMID:24453905
Oğuz, Yüksel; Güney, İrfan; Çalık, Hüseyin
2013-01-01
The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS) operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%.
Maklad, Ahmed Marzouk; Bayoumi, Yasser; Senosy Hassan, Mohamed Abdalazez; Elawadi, AbuSaleh A; AlHussain, Hussain; Elyamany, Ashraf; Aldhahri, Saleh F; Al-Qahtani, Khalid Hussain; AlQahtani, Mubarak; Tunio, Mutahir A
2016-01-01
Background We aimed to investigate the patterns of failure (locoregional and distant metastasis), associated factors, and treatment outcomes in nasopharyngeal carcinoma patients treated with intensity-modulated radiation therapy (IMRT) combined with chemotherapy. Patients and methods From April 2006 to December 2011, 68 nasopharyngeal carcinoma patients were treated with IMRT and chemotherapy at our hospital. Median radiation doses delivered to gross tumor volume and positive neck nodes were 66–70 Gy, 63 Gy to clinical target volume, and 50.4–56 Gy to clinically negative neck. The clinical toxicities, patterns of failures, locoregional control, distant metastasis control, disease-free survival, and overall survival were observed. Results The median follow-up time was 52.2 months (range: 11–87 months). Epstein–Barr virus infection was positive in 63.2% of patients. Overall disease failure developed in 21 patients, of whom 85.8% belonged to stage III/IV disease. Among these, there were seven locoregional recurrences, three regional recurrences with distant metastases, and eleven distant metastases. The median interval from the date of diagnosis to failure was 26.5 months (range: 16–50 months). Six of ten (60%) locoregional recurrences were treated with reirradiation ± concurrent chemotherapy. The 5-year locoregional control, distant metastasis control, disease-free survival, and overall survival rates of whole cohort were 81.1%, 74.3%, 60.1%, and 73.4%, respectively. Cox regression analyses revealed that neoadjuvant chemotherapy, age, and Epstein–Barr virus were independent predictors for disease-free survival. Conclusion Neoadjuvant chemotherapy followed by IMRT with or without chemotherapy improves the long-term survival of Saudi patients with nasopharyngeal carcinoma. Distant metastasis was the main pattern of treatment failure. Neoadjuvant chemotherapy, age, and Epstein–Barr virus status before IMRT were important independent prognostic factors. PMID:27822060
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muljadi, Eduard; Na, Woonki; Leighty, Bill
Self-Excited Induction Generation(SEIG) is very rugged, simple, lightweight, and it is easy and inexpensive to implement, very simple to control, and requires a very little maintenance. In this variable-speed operation, the SEIG needs a power electronics interface to convert from the variable frequency output voltage of the generator to a DC output voltage for battery or other DC applications. In our study, a SEIG is connected to the power electronics interface such as diode rectifier and DC/DC converter and then an electrolyzer is connected as a final DC load for fuel cell applications. An equivalent circuit model for an electrolyzermore » is utilized for our application. The control and analysis for the proposed system is carried out by using PSCAD and MATLAB software. This study would be useful for designing and control analysis of power interface circuits for SEIG for a variable speed wind turbine generation with fuel cell applications before the actual implementation.« less
Electronic circuit provides accurate sensing and control of dc voltage
NASA Technical Reports Server (NTRS)
Loftus, W. D.
1966-01-01
Electronic circuit used relay coil to sense and control dc voltage. The control relay is driven by a switching transistor that is biased to cutoff for all input up to slightly less than the threshold level.
Dc-To-Dc Converter Uses Reverse Conduction Of MOSFET's
NASA Technical Reports Server (NTRS)
Gruber, Robert P.; Gott, Robert W.
1991-01-01
In modified high-power, phase-controlled, full-bridge, pulse-width-modulated dc-to-dc converters, switching devices power metal oxide/semiconductor field-effect transistors (MOSFET's). Decreases dissipation of power during switching by eliminating approximately 0.7-V forward voltage drop in anti-parallel diodes. Energy-conversion efficiency increased.
Nirula, Ram; Millar, D; Greene, Tom; McFadden, Molly; Shah, Lubdha; Scalea, Thomas M; Stein, Deborah M; Magnotti, Louis J; Jurkovich, Gregory J; Vercruysse, Gary; Demetriades, Demetrios; Scherer, Lynette A; Peitzman, Andrew; Sperry, Jason; Beauchamp, Kathryn; Bell, Scott; Feiz-Erfan, Iman; O'Neill, Patrick; Coimbra, Raul
2014-04-01
Moderate/severe traumatic brain injury (TBI) management involves minimizing cerebral edema to maintain brain oxygen delivery. While medical therapy (MT) consisting of diuresis, hyperosmolar therapy, ventriculostomy, and barbiturate coma is the standard of care, decompressive craniectomy (DC) for refractory intracranial hypertension (ICH) has gained renewed interest. Since TBI treatment guidelines consider DC a second-tier intervention after MT failure, we sought to determine if early DC (<48 hours) was associated with improved survival in patients with refractory ICH. Eleven Level 1 trauma centers provided clinical data and head computed tomographic scans for patients with a Glasgow Coma Scale (GCS) score of 13 or less and radiographic evidence of TBI excluding deaths within 48 hours. Computed tomographic scans were graded according to the Marshall classification. A propensity score to receive DC (regardless of whether DC was performed) was calculated for each patient based on patient characteristics, physiology, injury severity, GCS, severity of intracranial injury, and treatment center. Patients who actually received a DC were matched to patients with similar propensity scores who received MT for analysis. Outcomes were compared between early (<48 hours of injury) primary or secondary DC and matched controls and then between early primary DC only and matched controls. There were 2,602 patients who met the inclusion criteria ,of whom 264 (10.1%) received DC (either primary or secondary to another cranial procedure) and 109 (5%) had a DC that was primary. Variables associated with performing a DC included sex, race, intracranial pressure monitor placement, in-house trauma attending, traumatic subarachnoid hemorrhage, midline shift, and basal cistern compression. There was no survival benefit with early primary DC compared with the controls (relative risk, 1.07; 95% confidence interval, 0.67-1.73; p = 0.77), and resource use was higher. Early DC does not seem to significantly improve mortality in patients with refractory ICH compared with MT. Neurosurgeons should pause before entertaining this resource-demanding form of therapy. Therapeutic care/management, level III.
1985-06-01
STUDY OF A BRUSHLESS DC MOTOR POWER CONDITIONER FOR A CRUISE MISSILE FIN CONTROL ACTUATOR CA. by Peter Norman MacMillan June 1985 Thesis Advisor: A...TYPE OF REPORT & PERIOD COVERED A CSMP Commutation Model for Design Master’s Thesis Study of a Brushless DC Motor Power June, 1985 Conditioner for a...tactical missiles. A dynamic equivalent circuit model for the analysis of a small four pole brushless DC motor fed ty a transistorized power conditioner
NASA Technical Reports Server (NTRS)
Edie, P. C.
1981-01-01
Straight and chopped DC motor performances for a Reliance EV-250AT motor with an EV-1 controller were examined. Effects of motor temperature and operating voltage are shown. It is found that the maximum motor efficiency is approximately 85% at low operating temperatures in the straight DC mode. Chopper efficiency is 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight DC mode.
Enhancement of Voltage Stability of DC Smart Grid During Islanded Mode by Load Shedding Scheme
NASA Astrophysics Data System (ADS)
Nassor, Thabit Salim; Senjyu, Tomonobu; Yona, Atsushi
2015-10-01
This paper presents the voltage stability of a DC smart grid based on renewable energy resources during grid connected and isolated modes. During the islanded mode the load shedding, based on the state of charge of the battery and distribution line voltage, was proposed for voltage stability and reservation of critical load power. The analyzed power system comprises a wind turbine, a photovoltaic generator, storage battery as controllable load, DC loads, and power converters. A fuzzy logic control strategy was applied for power consumption control of controllable loads and the grid-connected dual active bridge series resonant converters. The proposed DC Smart Grid operation has been verified by simulation using MATLAB® and PLECS® Blockset. The obtained results show the effectiveness of the proposed method.
NASA Astrophysics Data System (ADS)
Mohamed, Ahmed
Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available protection concepts and devices for AC systems in a DC network, were presented. A study was also conducted on the effect of changing the distribution architecture and distributing the storage assets on the various zones of the network on the system's dynamic security and stability. A practical shipboard power system was studied as an example of a hybrid AC/DC power system involving pulsed loads. Generally, the proposed hybrid AC/DC power system, besides most of the ideas, controls and algorithms presented in this dissertation, were experimentally verified at the Smart Grid Testbed, Energy Systems Research Laboratory. All the developments in this dissertation were experimentally verified at the Smart Grid Testbed.
Bamias, Giorgos; Kaltsa, Garyfallia; Siakavellas, Spyros I; Papaxoinis, Kostis; Zampeli, Evanthia; Michopoulos, Spyros; Zouboulis-Vafiadis, Irene; Ladas, Spiros D
2010-11-01
Decoy receptor-3 (DcR3) is a member of the TNF receptor superfamily of proteins, which has been implicated in anti-apoptotic and anti-inflammatory pathways, via binding to TL1A, LIGHT and Fas-L. The role of the TL1A/DcR3 ligand/receptor pair in ulcerative colitis (UC) has not been studied. We investigated the systemic (peripheral blood) and local (large intestine) expression of DcR3 and TL1A in 64 patients with UC and 56 healthy controls. DcR3 serum concentrations were highly elevated in patients with active UC (P<0.0001 vs. healthy controls). This elevation was clearly related to the presence of intestinal inflammation as it was less frequently observed in patients in remission (P=0.003 vs. active UC) whereas effective treatment resulted in disappearance or significant decrease of serum DcR3 (P=0.006 vs. pre-treatment). Furthermore, DcR3 mRNA transcripts were significantly elevated in inflamed areas of the colon (P=0.002 vs. non-affected of the same patient). In addition to DcR3 elevation, we found increased circulating levels of TL1A in patients with either active or inactive UC in comparison to healthy controls (P<0.001 for both). We conclude that elevated serum DcR3 may serve as an indicator of active colonic inflammation in patients with UC. TL1A/DcR3-mediated pathways may participate in the pathogenesis of UC. Copyright © 2010 Elsevier Inc. All rights reserved.
Multi-port power router and its impact on resilient power grid systems
NASA Astrophysics Data System (ADS)
Kado, Yuichi; Iwatsuki, Katsumi; Wada, Keiji
2016-02-01
We propose a Y-configuration power router as a unit cell to easily construct a power delivery system that can meet many types of user requirements. The Y-configuration power router controls the direction and magnitude of power flow among three ports regardless of DC and AC. We constructed a prototype three-way isolated DC/DC converter that is the core unit of the Y-configuration power router and tested the power flow control operation. Experimental results revealed that our methodology based on the governing equation was appropriate for the power flow control of the three-way DC/DC converter. In addition, the hexagonal distribution network composed of the power routers has the ability to easily interchange electric power between autonomous microgrid cells. We also explored the requirements for communication between energy routers to achieve dynamic adjustments of energy flow in a coordinated manner and its impact on resilient power grid systems.
Analysis of DC control in double-inlet GM type pulse tube refrigerators for detectors
NASA Astrophysics Data System (ADS)
Du, B. Y.
2016-10-01
Pulse tube refrigerators have demonstrated many advantages with respect to temperature stability, vibration, reliability and lifetime among cryo-coolers for detectors. Double-inlet type pulse tube refrigerators are popular in GM type pulse tube refrigerators. The single double-inlet valve may introduce DC flow in refrigerator, which deteriorates the performance of pulse tube refrigerator. One new type of DC control mode is introduced in this paper. Two parallel-placed needle valves with opposite direction named double-valve configuration, instead of single double-inlet valve, are used in our experiment to reduce the DC flow. With two double-inlet operating, the lowest cold end temperature of 18.1K and a coolant of 1.2W@20K have been obtained. It has proved that this method is useful for controlling DC flow of the pulse tube refrigerators, which is very important to understand the characters of pulse tube refrigerators for detectors.
Frequency tuning allows flow direction control in microfluidic networks with passive features.
Jain, Rahil; Lutz, Barry
2017-05-02
Frequency tuning has emerged as an attractive alternative to conventional pumping techniques in microfluidics. Oscillating (AC) flow driven through a passive valve can be rectified to create steady (DC) flow, and tuning the excitation frequency to the characteristic (resonance) frequency of the underlying microfluidic network allows control of flow magnitude using simple hardware, such as an on-chip piezo buzzer. In this paper, we report that frequency tuning can also be used to control the direction (forward or backward) of the rectified DC flow in a single device. Initially, we observed that certain devices provided DC flow in the "forward" direction expected from previous work with a similar valve geometry, and the maximum DC flow occurred at the same frequency as a prominent peak in the AC flow magnitude, as expected. However, devices of a slightly different geometry provided the DC flow in the opposite direction and at a frequency well below the peak AC flow. Using an equivalent electrical circuit model, we found that the "forward" DC flow occurred at the series resonance frequency (with large AC flow peak), while the "backward" DC flow occurred at a less obvious parallel resonance (a valley in AC flow magnitude). We also observed that the DC flow occurred only when there was a measurable differential in the AC flow magnitude across the valve, and the DC flow direction was from the channel with large AC flow magnitude to that with small AC flow magnitude. Using these observations and the AC flow predictions from the equivalent circuit model, we designed a device with an AC flowrate frequency profile that was expected to allow the DC flow in opposite directions at two distinct frequencies. The fabricated device showed the expected flow reversal at the expected frequencies. This approach expands the flow control toolkit to include both magnitude and direction control in frequency-tuned microfluidic pumps. The work also raises interesting questions about the origin of flow reversal behavior that may be addressed by the further study of the circuit model behavior or dynamic modeling of the fluid-solid mechanics of the valve under the AC flow.
Formation Flying in Earth, Libration, and Distant Retrograde Orbits
NASA Technical Reports Server (NTRS)
Folta, David C.
2004-01-01
This slide presentation examines the current and future state of formation flying, LEO formations, control strategies for flight in the vicinity of the libration points, and distant retrograde orbit formations. This discussion of LEO formations includes background on perturbation theory/accelerations and LEO formation flying. The discussion of strategies for formation flight in the vicinity of the libration points includes libration missions and natural and controlled libration orbit formations. A reference list is included.
Triple voltage dc-to-dc converter and method
Su, Gui-Jia
2008-08-05
A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.
Mossu, Adrien; Daoui, Anna; Bonnefoy, Francis; Aubergeon, Lucie; Saas, Philippe; Perruche, Sylvain
2016-09-01
Regulation of the inflammatory response involves the control of dendritic cell survival. To our knowledge, nothing is known about the survival of plasmacytoid dendritic cells (pDC) in such situation. pDC are specialized in type I IFN (IFN-I) secretion to control viral infections, and IFN-I also negatively regulate pDC survival during the course of viral infections. In this study, we asked about pDC behavior in the setting of virus-free inflammation. We report that pDC survival was profoundly reduced during different nonviral inflammatory situations in the mouse, through a mechanism independent of IFN-I and TLR signaling. Indeed, we demonstrated that during inflammation, CD8(+) T cells induced pDC apoptosis through the perforin pathway. The data suggest, therefore, that pDC have to be turned down during ongoing acute inflammation to not initiate autoimmunity. Manipulating CD8(+) T cell response may therefore represent a new therapeutic opportunity for the treatment of pDC-associated autoimmune diseases, such as lupus or psoriasis. Copyright © 2016 by The American Association of Immunologists, Inc.
A Standalone Solar Photovoltaic Power Generation using Cuk Converter and Single Phase Inverter
NASA Astrophysics Data System (ADS)
Verma, A. K.; Singh, B.; Kaushika, S. C.
2013-03-01
In this paper, a standalone solar photovoltaic (SPV) power generating system is designed and modeled using a Cuk dc-dc converter and a single phase voltage source inverter (VSI). In this system, a dc-dc boost converter boosts a low voltage of a PV array to charge a battery at 24 V using a maximum power point tracking control algorithm. To step up a 24 V battery voltage to 360 V dc, a high frequency transformer based isolated dc-dc Cuk converter is used to reduce size, weight and losses. The dc voltage of 360 V is fed to a single phase VSI with unipolar switching to achieve a 230 Vrms, 50 Hz ac. The main objectives of this investigation are on efficiency improvement, reduction in cost, weight and size of the system and to provide an uninterruptible power to remotely located consumers. The complete SPV system is designed and it is modeled in MATLAB/Simulink. The simulated results are presented to demonstrate its satisfactory performance for validating the proposed design and control algorithm.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-25
... Airworthiness Limitations inspections (ALIs). This proposed AD results from a design review of the fuel tank...,'' and also adds ALI 30-1 for a pneumatic system decay check to minimize the risk of hot air impingement... 5, 2010, adds ALI 28-1, ``DC-8 Alternate and Center Auxiliary Tank Fuel Pump Control Systems Check...
NASA Technical Reports Server (NTRS)
Frederick, Martin E. (Inventor); Jermakian, Joel (Inventor)
1991-01-01
A method and an apparatus is provided for efficiently controlling the power output of a solar cell array string or a plurality of solar cell array strings to achieve a maximum amount of output power from the strings under varying conditions of use. Maximum power output from a solar array string is achieved through control of a pulse width modulated DC/DC buck converter which transfers power from a solar array to a load or battery bus. The input voltage from the solar array to the converter is controlled by a pulse width modulation duty cycle, which in turn is controlled by a differential signal controller. By periodically adjusting the control voltage up or down by a small amount and comparing the power on the load or bus with that generated at different voltage values a maximum power output voltage may be obtained. The system is totally modular and additional solar array strings may be added to the system simply by adding converter boards to the system and changing some constants in the controller's control routines.
[Distant mental influence on living organisms].
Bonilla, Ernesto
2013-12-01
This article reviews studies of distant mental influence on living organisms, including mental suggestions of sleeping and awakening, mental influence at long distances, mental interactions with remote biological systems, mental effects on physiological activity and the sense of being stared at. Significant effects of distant mental influence have been shown in several randomized controlled trials in humans, animals, plants, bacteria and cells in the laboratory. Although distant mental influence on living organisms appears to contradict our ordinary sense of reality and the laws defined by conventional science, several hypotheses have been proposed to explain the observed effects; they include skeptical, signal transfer, field, multidimensional space/time and quantum mechanics hypotheses. In conclusion, as the progress of physics continues to expand our comprehension of reality, a rational explanation for distant mind-matter interaction will emerge and, as history has shown repeatedly, the supernatural events will evolve into paranormal and then, into normal ones, as the scientific frontiers expand.
Deeny, Sean; Chicoine, Caitlin; Hargrove, Levi; Parrish, Todd; Jayaraman, Arun
2014-01-01
Common goals in the development of human-machine interface (HMI) technology are to reduce cognitive workload and increase function. However, objective and quantitative outcome measures assessing cognitive workload have not been standardized for HMI research. The present study examines the efficacy of a simple event-related potential (ERP) measure of cortical effort during myoelectric control of a virtual limb for use as an outcome tool. Participants trained and tested on two methods of control, direct control (DC) and pattern recognition control (PRC), while electroencephalographic (EEG) activity was recorded. Eighteen healthy participants with intact limbs were tested using DC and PRC under three conditions: passive viewing, easy, and hard. Novel auditory probes were presented at random intervals during testing, and significant task-difficulty effects were observed in the P200, P300, and a late positive potential (LPP), supporting the efficacy of ERPs as a cognitive workload measure in HMI tasks. LPP amplitude distinguished DC from PRC in the hard condition with higher amplitude in PRC, consistent with lower cognitive workload in PRC relative to DC for complex movements. Participants completed trials faster in the easy condition using DC relative to PRC, but completed trials more slowly using DC relative to PRC in the hard condition. The results provide promising support for ERPs as an outcome measure for cognitive workload in HMI research such as prosthetics, exoskeletons, and other assistive devices, and can be used to evaluate and guide new technologies for more intuitive HMI control.
Zener diode controls switching of large direct currents
NASA Technical Reports Server (NTRS)
1965-01-01
High-current zener diode is connected in series with the positive input terminal of a dc supply to block the flow of direct current until a high-frequency control signal is applied across the zener diode. This circuit controls the switching of large dc signals.
R Dump Converter without DC Link Capacitor for an 8/6 SRM: Experimental Investigation
Kavitha, Pasumalaithevan; Umamaheswari, Bhaskaran
2015-01-01
The objective of this paper is to investigate the performance of 8/6 switched reluctance motor (SRM) when excited with sinusoidal voltage. The conventional R dump converter provides DC excitation with the help of capacitor. In this paper the converter used is the modified R dump converter without DC link capacitor providing AC or sinusoidal excitation. Torque ripple and speed ripple are investigated based on hysteresis current control. Constant and sinusoidal current references are considered for comparison in both DC and AC excitation. Extensive theoretical and experimental investigations are made to bring out the merits and demerits of AC versus DC excitation. It is shown that the constructionally simple SRM can be favorably controlled with simple R dump converter with direct AC excitation without need for DC link capacitor. A 4-phase 8/6 0.5 kW SRM is used for experimentation. PMID:25642452
R dump converter without DC link capacitor for an 8/6 SRM: experimental investigation.
Kavitha, Pasumalaithevan; Umamaheswari, Bhaskaran
2015-01-01
The objective of this paper is to investigate the performance of 8/6 switched reluctance motor (SRM) when excited with sinusoidal voltage. The conventional R dump converter provides DC excitation with the help of capacitor. In this paper the converter used is the modified R dump converter without DC link capacitor providing AC or sinusoidal excitation. Torque ripple and speed ripple are investigated based on hysteresis current control. Constant and sinusoidal current references are considered for comparison in both DC and AC excitation. Extensive theoretical and experimental investigations are made to bring out the merits and demerits of AC versus DC excitation. It is shown that the constructionally simple SRM can be favorably controlled with simple R dump converter with direct AC excitation without need for DC link capacitor. A 4-phase 8/6 0.5 kW SRM is used for experimentation.
Experimental Investigation of DC-Bias Related Core Losses in a Boost Inductor (Postprint)
2014-08-01
dc bias-flux conditions. These dc bias conditions result in distorted hysteresis loops , increased core losses, and have been shown to be independent...These dc bias conditions result in dis- torted hysteresis loops , increased core losses, and have been shown to be independent of core material. The...controllable converter load currents, this topology is ideal to study dc-related losses. Inductor core hysteresis loop characterization was accomplished
Solid state circuit controls direction, speed, and braking of dc motor
NASA Technical Reports Server (NTRS)
Hanna, M. F.
1966-01-01
Full-wave bridge rectifier circuit controls the direction, speed, and braking of a dc motor. Gating in the circuit of Silicon Controlled Rectifiers /SCRS/ controls output polarity and braking is provided by an SCR that is gated to short circuit the reverse voltage generated by reversal of motor rotation.
Model predictive controller design for boost DC-DC converter using T-S fuzzy cost function
NASA Astrophysics Data System (ADS)
Seo, Sang-Wha; Kim, Yong; Choi, Han Ho
2017-11-01
This paper proposes a Takagi-Sugeno (T-S) fuzzy method to select cost function weights of finite control set model predictive DC-DC converter control algorithms. The proposed method updates the cost function weights at every sample time by using T-S type fuzzy rules derived from the common optimal control engineering knowledge that a state or input variable with an excessively large magnitude can be penalised by increasing the weight corresponding to the variable. The best control input is determined via the online optimisation of the T-S fuzzy cost function for all the possible control input sequences. This paper implements the proposed model predictive control algorithm in real time on a Texas Instruments TMS320F28335 floating-point Digital Signal Processor (DSP). Some experimental results are given to illuminate the practicality and effectiveness of the proposed control system under several operating conditions. The results verify that our method can yield not only good transient and steady-state responses (fast recovery time, small overshoot, zero steady-state error, etc.) but also insensitiveness to abrupt load or input voltage parameter variations.
Charbonnier, Anne-Sophie; Hammad, Hamida; Gosset, Philippe; Stewart, Geoffrey A; Alkan, Sefik; Tonnel, André-Bernard; Pestel, Joël
2003-01-01
Although reports suggest that dendritic cells (DC) are involved in the allergic reaction characterized by a T helper cell type 2 (Th2) profile, the role of myeloid (M-DC) and plasmacytoid DC (P-DC), controlling the balance Th1/Th2, remains unknown. Here, we showed that in Dermatophagoides pteronyssinus (Dpt)-sensitized allergic patients and in healthy donors, M-DC displayed a higher capacity to capture Der p 1, a major allergen of Dpt, than did P-DC. However, Der p 1-pulsed M-DC from healthy subjects overexpressed CD80 and secreted interleukin (IL)-10, whereas M-DC from allergic patients did not. In contrast, with Der p 1-pulsed P-DC from both groups, no increase in human leukocyte antigen-DR, CD80, and CD86 and no IL-10 secretion were detected. When cocultured with allogeneic naive CD4(+) T cells from healthy donors, Der p 1-pulsed M-DC from allergic patients favored a Th1 profile [interferon (IFN)-gamma(high)/IL-4(low)] and Der p 1-pulsed P-DC, a Th2 profile (IFN-gamma(low)/IL-4(high)). In healthy donors, no T cell polarization (IFN-gamma(low)/IL-4(low)) was induced by Der p 1-pulsed M-DC or P-DC, but in response to Der p 1-pulsed M-DC, T cells secreted IL-10. The neutralization of IL-10 produced by Der p 1-pulsed M-DC from healthy donors led to an inhibition of IL-10 production by T cells and a polarization toward a type 1. Thus, IL-10 produced by M-DC might be an essential mediator controlling the balance between tolerance and allergic status. In addition, P-DC could contribute to the steady state in healthy donors or to the development of a Th2 response in allergic donors.
14 CFR 93.339 - Requirements for operating in the DC SFRA, including the DC FRZ.
Code of Federal Regulations, 2010 CFR
2010-01-01
... aircraft in the DC SFRA, including the DC FRZ, the pilot obtains and transmits a discrete transponder code... flight plan by obtaining a discrete transponder code. The flight plan is closed upon landing at an... transmitting an Air Traffic Control-assigned discrete transponder code. (c) When operating an aircraft in the...
An Improved Power Quality BIBRED Converter-Based VSI-Fed BLDC Motor Drive
NASA Astrophysics Data System (ADS)
Singh, Bhim; Bist, Vashist
2014-01-01
This paper presents an IHQRR (integrated high-quality rectifier regulator) BIBRED (boost integrated buck rectifier energy storage DC-DC) converter-based VSI (voltage source inverter)-fed BLDC (brushless DC) motor drive. The speed control of BLDC motor is achieved by controlling the DC link voltage of the VSI using a single voltage sensor. This allows VSI to operate in fundamental frequency switching mode for electronic commutation of BLDC motor which reduces the switching losses due to high-frequency switching used in conventional approach of PWM (pulse width modulation)-based VSI-fed BLDC motor drive. A BIBRED converter is operated in a dual-DCM (discontinuous conduction mode) thus using a voltage follower approach for PFC (power factor correction) and DC link voltage control. The performance of the proposed drive is evaluated for improved power quality over a wide range of speed control and supply voltage variation for demonstrating the behavior of proposed drive. The power quality indices thus obtained are within the recommended limits by international PQ (power quality) standards such as IEC 61000-3-2.
Early Oscillation Detection for Hybrid DC/DC Converter Fault Diagnosis
NASA Technical Reports Server (NTRS)
Wang, Bright L.
2011-01-01
This paper describes a novel fault detection technique for hybrid DC/DC converter oscillation diagnosis. The technique is based on principles of feedback control loop oscillation and RF signal modulations, and Is realized by using signal spectral analysis. Real-circuit simulation and analytical study reveal critical factors of the oscillation and indicate significant correlations between the spectral analysis method and the gain/phase margin method. A stability diagnosis index (SDI) is developed as a quantitative measure to accurately assign a degree of stability to the DC/DC converter. This technique Is capable of detecting oscillation at an early stage without interfering with DC/DC converter's normal operation and without limitations of probing to the converter.
Power Strategy in DC/DC Converters to Increase Efficiency of Electrical Stimulators.
Aqueveque, Pablo; Acuña, Vicente; Saavedra, Francisco; Debelle, Adrien; Lonys, Laurent; Julémont, Nicolas; Huberland, François; Godfraind, Carmen; Nonclercq, Antoine
2016-06-13
Power efficiency is critical for electrical stimulators. Battery life of wearable stimulators and wireless power transmission in implanted systems are common limiting factors. Boost DC/DC converters are typically needed to increase the supply voltage of the output stage. Traditionally, boost DC/DC converters are used with fast control to regulate the supply voltage of the output. However, since stimulators are acting as current sources, such voltage regulation is not needed. Banking on this, this paper presents a DC/DC conversion strategy aiming to increase power efficiency. It compares, in terms of efficiency, the traditional use of boost converters to two alternatives that could be implemented in future hardware designs.
UDE-based control of variable-speed wind turbine systems
NASA Astrophysics Data System (ADS)
Ren, Beibei; Wang, Yeqin; Zhong, Qing-Chang
2017-01-01
In this paper, the control of a PMSG (permanent magnet synchronous generator)-based variable-speed wind turbine system with a back-to-back converter is considered. The uncertainty and disturbance estimator (UDE)-based control approach is applied to the regulation of the DC-link voltage and the control of the RSC (rotor-side converter) and the GSC (grid-side converter). For the rotor-side controller, the UDE-based vector control is developed for the RSC with PMSG control to facilitate the application of the MPPT (maximum power point tracking) algorithm for the maximum wind energy capture. For the grid-side controller, the UDE-based vector control is developed to control the GSC with the power reference generated by a UDE-based DC-link voltage controller. Compared with the conventional vector control, the UDE-based vector control can achieve reliable current decoupling control with fast response. Moreover, the UDE-based DC-link voltage regulation can achieve stable DC-link voltage under model uncertainties and external disturbances, e.g. wind speed variations. The effectiveness of the proposed UDE-based control approach is demonstrated through extensive simulation studies in the presence of coupled dynamics, model uncertainties and external disturbances under varying wind speeds. The UDE-based control is able to generate more energy, e.g. by 5% for the wind profile tested.
Nerve lesioning with direct current
NASA Astrophysics Data System (ADS)
Ravid, E. Natalie; Shi Gan, Liu; Todd, Kathryn; Prochazka, Arthur
2011-02-01
Spastic hypertonus (muscle over-activity due to exaggerated stretch reflexes) often develops in people with stroke, cerebral palsy, multiple sclerosis and spinal cord injury. Lesioning of nerves, e.g. with phenol or botulinum toxin is widely performed to reduce spastic hypertonus. We have explored the use of direct electrical current (DC) to lesion peripheral nerves. In a series of animal experiments, DC reduced muscle force by controlled amounts and the reduction could last several months. We conclude that in some cases controlled DC lesioning may provide an effective alternative to the less controllable molecular treatments available today.
NASA Astrophysics Data System (ADS)
Nwosu, Cajethan M.; Ogbuka, Cosmas U.; Oti, Stephen E.
2017-08-01
This paper presents a control model design capable of inhibiting the phenomenal rise in the DC-link voltage during grid- fault condition in a variable speed wind turbine. Against the use of power circuit protection strategies with inherent limitations in fault ride-through capability, a control circuit algorithm capable of limiting the DC-link voltage rise which in turn bears dynamics that has direct influence on the characteristics of the rotor voltage especially during grid faults is here proposed. The model results so obtained compare favorably with the simulation results as obtained in a MATLAB/SIMULINK environment. The generated model may therefore be used to predict near accurately the nature of DC-link voltage variations during fault given some factors which include speed and speed mode of operation, the value of damping resistor relative to half the product of inner loop current control bandwidth and the filter inductance.
Maximum Power Point tracking charge controllers for telecom applications -- Analysis and economics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wills, R.H.
Simple charge controllers connect photovoltaic modules directly to the battery bank resulting in a significant power loss if the battery bank voltage differs greatly from the PV Maximum Power Point (MPP) voltage. Recent modeling work at AES has shown that dc-dc converter type MPP tracking charge controllers can deliver more than 30% more energy from PV modules to the battery when the PV modules are cool and the battery state of charge is low--this is typically both the worst case condition (i.e., winter) and also the design condition that determines the PV array size. Economic modeling, based on typical telecommore » system installed costs shows benefits of more than $3/Wp for MPPT over conventional charge controllers in this application--a value that greatly exceeds the additional cost of the dc-dc converter.« less
Electric power processing, distribution and control for advanced aerospace vehicles.
NASA Technical Reports Server (NTRS)
Krausz, A.; Felch, J. L.
1972-01-01
The results of a current study program to develop a rational basis for selection of power processing, distribution, and control configurations for future aerospace vehicles including the Space Station, Space Shuttle, and high-performance aircraft are presented. Within the constraints imposed by the characteristics of power generation subsystems and the load utilization equipment requirements, the power processing, distribution and control subsystem can be optimized by selection of the proper distribution voltage, frequency, and overload/fault protection method. It is shown that, for large space vehicles which rely on static energy conversion to provide electric power, high-voltage dc distribution (above 100 V dc) is preferable to conventional 28 V dc and 115 V ac distribution per MIL-STD-704A. High-voltage dc also has advantages over conventional constant frequency ac systems in many aircraft applications due to the elimination of speed control, wave shaping, and synchronization equipment.
40 CFR 725.60 - Withdrawal of submission by the submitter.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., OPPT Document Control Office (DCO), EPA East Bldg., 1201 Constitution Ave., NW., Rm. 6428, Washington... Control Office (DCO), EPA East Bldg., 1201 Constitution Ave., NW., Rm. 6428, Washington, DC 20004. (ii... Document Control Office (DCO), EPA East Bldg., 1201 Constitution Ave., NW., Rm. 6428, Washington, DC 20004...
Alexandre, Yannick O.; Cocita, Clément D.; Ghilas, Sonia; Dalod, Marc
2014-01-01
Infection of mice with murine cytomegalovirus (MCMV) recapitulates many physiopathological characteristics of human CMV infection and enables studying the interactions between a virus and its natural host. Dendritic cells (DC) are mononuclear phagocytes linking innate and adaptive immunity which are both necessary for MCMV control. DC are critical for the induction of cellular immunity because they are uniquely efficient for the activation of naïve T cells during their first encounter with a pathogen. DC are equipped with a variety of innate immune recognition receptors (I2R2) allowing them to detect pathogens or infections and to engulf molecules, microorganisms or cellular debris. The combinatorial engagement of I2R2 during infections controls DC maturation and shapes their response in terms of cytokine production, activation of natural killer (NK) cells and functional polarization of T cells. Several DC subsets exist which express different arrays of I2R2 and are specialized in distinct functions. The study of MCMV infection helped deciphering the physiological roles of DC subsets and their molecular regulation. It allowed the identification and first in vivo studies of mouse plasmacytoid DC which produce high level of interferons-α/β early after infection. Despite its ability to infect DC and dampen their functions, MCMV induces very robust, efficient and long-lasting CD8 T cell responses. Their priming may rely on the unique ability of uninfected XCR1+ DC to cross-present engulfed viral antigens and thus to counter MCMV interference with antigen presentation. A balance appears to have been reached during co-evolution, allowing controlled replication of the virus for horizontal spread without pathological consequences for the immunocompetent host. We will discuss the role of the interplay between the virus and DC in setting this balance, and how advancing this knowledge further could help develop better vaccines against other intracellular infectious agents. PMID:25120535
Kho, Steven; Marfurt, Jutta; Handayuni, Irene; Pava, Zuleima; Noviyanti, Rintis; Kusuma, Andreas; Piera, Kim A; Burdam, Faustina H; Kenangalem, Enny; Lampah, Daniel A; Engwerda, Christian R; Poespoprodjo, Jeanne R; Price, Ric N; Anstey, Nicholas M; Minigo, Gabriela; Woodberry, Tonia
2016-06-21
Plasmodium falciparum and Plasmodium vivax infections compromise dendritic cell (DC) function and expand regulatory T (Treg) cells in both clinical disease (malaria) and experimental human sub-microscopic infection. Conversely, in asymptomatic microscopy-positive (patent) P. falciparum or P. vivax infection in endemic areas, blood DC increase or retain HLA-DR expression and Treg cells exhibit reduced activation, suggesting that DC and Treg cells contribute to the control of patent asymptomatic infection. The effect of sub-microscopic (sub-patent) asymptomatic Plasmodium infection on DC and Treg cells in malaria-endemic area residents remains unclear. In a cross-sectional household survey conducted in Papua, Indonesia, 162 asymptomatic adults were prospectively evaluated for DC and Treg cells using field-based flow cytometry. Of these, 161 individuals (99 %) were assessed retrospectively by polymerase chain reaction (PCR), 19 of whom had sub-microscopic infection with P. falciparum and 15 with sub-microscopic P. vivax infection. Flow cytometric data were re-analysed after re-grouping asymptomatic individuals according to PCR results into negative controls, sub-microscopic and microscopic parasitaemia to examine DC and Treg cell phenotype in sub-microscopic infection. Asymptomatic adults with sub-microscopic P. falciparum or P. vivax infection had DC HLA-DR expression and Treg cell activation comparable to PCR-negative controls. Sub-microscopic P. falciparum infection was associated with lower peripheral CD4(+) T cells and lymphocytes, however sub-microscopic Plasmodium infection had no apparent effect on DC sub-set number or Treg cell frequency. In contrast to the impairment of DC maturation/function and the activation of Treg cells seen with sub-microscopic parasitaemia in primary experimental human Plasmodium infection, no phenotypic evidence of dysregulation of DC and Treg cells was observed in asymptomatic sub-microscopic Plasmodium infection in Indonesian adults. This is consistent with DC and Treg cells retaining their functional capacity in sub-microscopic asymptomatic infection with P. falciparum or P. vivax in malaria-endemic areas.
Summary of electric vehicle dc motor-controller tests
NASA Technical Reports Server (NTRS)
Mcbrien, E. F.; Tryon, H. B.
1982-01-01
The differences in the performance of dc motors are evaluated when operating with chopper type controllers, and when operating on direct current. The interactions between the motor and the controller which cause these differences are investigated. Motor-controlled tests provided some of the data the quantified motor efficiency variations for both ripple free and chopper modes of operation.
Regulation of a lightweight high efficiency capacitator diode voltage multiplier dc-dc converter
NASA Technical Reports Server (NTRS)
Harrigill, W. T., Jr.; Myers, I. T.
1976-01-01
A method for the regulation of a capacitor diode voltage multiplier dc-dc converter has been developed which has only minor penalties in weight and efficiency. An auxiliary inductor is used, which only handles a fraction of the total power, to control the output voltage through a pulse width modulation method in a buck boost circuit.
AVR Microcontroller-based automated technique for analysis of DC motors
NASA Astrophysics Data System (ADS)
Kaur, P.; Chatterji, S.
2014-01-01
This paper provides essential information on the development of a 'dc motor test and analysis control card' using AVR series ATMega32 microcontroller. This card can be interfaced to PC and calculates parameters like motor losses, efficiency and plot characteristics for dc motors. Presently, there are different tests and methods available to evaluate motor parameters, but a single and universal user-friendly automated set-up has been discussed in this paper. It has been accomplished by designing a data acquisition and SCR bridge firing hardware based on AVR ATMega32 microcontroller. This hardware has the capability to drive the phase-controlled rectifiers and acquire real-time values of current, voltage, temperature and speed of motor. Various analyses feasible with the designed hardware are of immense importance for dc motor manufacturers and quality-sensitive users. Authors, through this paper aim to provide details of this AVR-based hardware which can be used for dc motor parameter analysis and also for motor control applications.
Multiport power router and its impact on future smart grids
NASA Astrophysics Data System (ADS)
Kado, Yuichi; Shichijo, Daiki; Wada, Keiji; Iwatsuki, Katsumi
2016-07-01
We propose a Y configuration power router as a unit cell to easily construct a power delivery system that can meet many types of user requirements. The Y configuration power router controls the direction and magnitude of power flows between three ports regardless of DC or AC. We constructed a prototype three-way isolated DC/DC converter that is the core unit of the Y configuration power router. The electrical insulation between three ports assures safety and reliability for power network systems. We then tested the operation of power flow control. The experimental results revealed that our methodology based on a governing equation was appropriate to control the power flow of the three-way DC/DC converter. In addition, a distribution network composed of power routers had the ability to easily enable interchanges of electrical power between autonomous microgrid cells. We also explored the requirements for communication between energy routers to achieve dynamic adjustments of energy flows in a coordinated manner and their impact on resilient power grid systems.
Kostolanska, J; Jakus, V; Barak, L; Stanikova, A; Waczulikova, I
2010-01-01
We tried to investigate whether the AGEs in serum and lipoperoxides (LPO) monitoring were suitable for an early prediction of diabetic complications (DC) development in diabetological practice. We wanted to find whether it is better to divide the file according to the presence of DC or in terms of glycemic compensation in this study. 79 diabetic patients with duration of disease for at least 5 years were divided in respect to DC presence/absence and also to long-time glycemic compensation. HbA1c was measured by LPLC in fair capillary blood, s-AGEs were estimated spectrofluorimetrically and LPO iodimetrically and spectrophotometrically in serum. HbA1c, s-AGEs and LPO were significantly higher in the group with DC (+DC) vs. controls and also in -DC vs. controls. HbA1c and s-AGEs were significantly higher in +DC vs. patients without DC (-DC). HbA1c, s-AGEs and LPO were significantly higher in patients with poor glycemic compensation (PGC) compared to controls and HbA1c and LPO in patients with good glycemic compensation (GGC) compared to controls. HbA1c and s-AGEs were significantly higher in PGC vs. GGC. In the group of GGC we have found interesting significant correlations of HbA1c with HDL (r=0.451, p<0.05) and with LDL (r=-0.450, p<0.05). Our findings suggest that the monitoring of s-AGEs in poorly compensated diabetic patients and LPO in all may be very useful to recognize the risk of complications. The dividing of patient file in terms of long time glycemic compensation is more reliable for research of this issue (Tab. 3, Fig. 6, Ref. 41). Full Text in free PDF www.bmj.sk.
NASA Astrophysics Data System (ADS)
Faisal, A.; Hasan, S.; Suherman
2018-03-01
AC-DC converter is widely used in the commercial industry even for daily purposes. The AC-DC converter is used to convert AC voltage into DC. In order to obtain the desired output voltage, the converter usually has a controllable regulator. This paper discusses buck boost regulator with a power MOSFET as switching component which is adjusted based on the duty cycle of pulse width modulation (PWM). The main problems of the buck boost converter at start up are the high overshoot, the long peak time and rise time. This paper compares the effectiveness of two control techniques: proportional integral derivative (PID) and fuzzy logic control in controlling the buck boost converter through simulations. The results show that the PID is more sensitive to voltage change than fuzzy logic. However, PID generates higher overshoot, long peak time and rise time. On the other hand, fuzzy logic generates no overshoot and shorter rise time.
Investigations into the use of energy storage in power system applications
NASA Astrophysics Data System (ADS)
Leung, Ka Kit
This thesis embodies research work on the design and implementation of novel fast responding battery energy storage systems, which, with sufficient capacity and rating, could remove the uncertainty in forecasting the annual peak demand. They would also benefit the day to day operation by curtailing the fastest demand variations, particularly at the daily peak periods. Energy storage that could curtail peak demands, when the most difficult operational problems occur offers a promising approach. Although AC energy cannot be stored, power electronic developments offer a fast responding interface between the AC network and DC energy stored in batteries. The attractive feature of the use of this energy storage could most effectively be located near the source of load variations, i.e. near consumers in the distribution networks. The proposed, three phase multi-purpose, Battery Energy Storage System will provide active and reactive power independent of the supply voltage with excellent power quality in terms of its waveform. Besides the above important functions applied at the distribution side of the utility, several new topologies have been developed to provide both Dynamic Voltage Regulator (DVR) and Unified Power Flow Controller (UPFC) functions for line compensation. These new topologies can provide fast and accurate control of power flow along a distribution corridor. The topologies also provide for fast damping of system oscillation due to transient or dynamic disturbances. Having demonstrated the various functions that the proposed Battery Energy Storage System can provide, the final part of the thesis investigates means of improving the performance of the proposed BESS. First, there is a need to reduce the switching losses by using soft switching instead of hard switching. A soft switching inverter using a parallel resonant dc-link (PRDCL) is proposed for use with the proposed BESS. The proposed PRDCL suppresses the dc-link voltage to zero for a very short time to allow zero voltage switching of inverter main switches without imposing excessive voltage and current stresses. Finally, in practice the battery terminal voltage fluctuates significantly as large current is being drawn or absorbed by the battery bank. When a hysteresis controller is used to control the supply line current, the ripple magnitude and frequency of the controlled current is highly dependent on the battery voltage, line inductance and the band limits of the controller. Even when these parameters are constant, the switching frequency can vary over quite a large range. A novel method is proposed to overcome this problem by controlling the dc voltage level by means of a dc-dc converter to provide a controllable voltage at the inverter dc terminal irrespective of the battery voltage variations. By proper control of the magnitude and frequency of the output of the DC-DC converter, the switching frequency can be made close to constant. A mathematical proof has been formulated and results from the simulation confirm that using the proposed technique, the frequency band has been significantly reduced and for the theoretical case, a single switching frequency is observed. The main disadvantage is the need to have an extra dc-dc converter, but this is relatively cheap and easy to obtain.
Highly sensitive vacuum ion pump current measurement system
Hansknecht, John Christopher [Williamsburg, VA
2006-02-21
A vacuum system comprising: 1) an ion pump; 2) power supply; 3) a high voltage DC--DC converter drawing power from the power supply and powering the vacuum pump; 4) a feedback network comprising an ammeter circuit including an operational amplifier and a series of relay controlled scaling resistors of different resistance for detecting circuit feedback; 5) an optional power block section intermediate the power supply and the high voltage DC--DC converter; and 6) a microprocessor receiving feedback information from the feedback network, controlling which of the scaling resistors should be in the circuit and manipulating data from the feedback network to provide accurate vacuum measurement to an operator.
Control of a lithium-ion battery storage system for microgrid applications
NASA Astrophysics Data System (ADS)
Pegueroles-Queralt, Jordi; Bianchi, Fernando D.; Gomis-Bellmunt, Oriol
2014-12-01
The operation of future microgrids will require the use of energy storage systems employing power electronics converters with advanced power management capacities. This paper presents the control scheme for a medium power lithium-ion battery bidirectional DC/AC power converter intended for microgrid applications. The switching devices of a bidirectional DC converter are commanded by a single sliding mode control law, dynamically shaped by a linear voltage regulator in accordance with the battery management system. The sliding mode controller facilitates the implementation and design of the control law and simplifies the stability analysis over the entire operating range. Control parameters of the linear regulator are designed to minimize the impact of commutation noise in the DC-link voltage regulation. The effectiveness of the proposed control strategy is illustrated by experimental results.
Low Cost Embedded Controlled Full Bridge LC Parallel Resonant Converter
NASA Astrophysics Data System (ADS)
Chandrasekhar, P.; Reddy, S.
2009-01-01
In this paper the converter requirements for an optimum control of an electrolyser linked with a DC bus are analyzed and discussed. An electrolyser is a part of renewable energy system which generates hydrogen from water electrolysis. The hydrogen generating device is part of a complex system constituted by a supplying photovoltaic plant, the grid and a fuel cell battery. The characterization in several operative conditions of an actual industrial electrolyser is carried out in order to design and optimize the DC/DC converter. A dedicated zero voltage switching DC/DC converter is presented and simulated inside the context of the distributed energy production and storage system. The proposed supplying converter gives a stable output voltage and high circuit efficiency in all the proposed simulated scenarios. The adopted DC/DC converter is realized in a full-bridge topology technique in order to achieve zero voltage switching for the power switches and to regulate the output voltage. This converter has advantages like high power density, low EMI and reduced switching stresses. The simulation results are verified with the experimental results.
Hardware Evolution of Analog Speed Controllers for a DC Motor
NASA Technical Reports Server (NTRS)
Gwaltney, David A.; Ferguson, Michael I.
2003-01-01
Evolvable hardware provides the capability to evolve analog circuits to produce amplifier and filter functions. Conventional analog controller designs employ these same functions. Analog controllers for the control of the shaft speed of a DC motor are evolved on an evolvable hardware platform utilizing a Field Programmable Transistor Array (FPTA). The performance of these evolved controllers is compared to that of a conventional proportional-integral (PI) controller.
Analysis of self-oscillating dc-to-dc converters
NASA Technical Reports Server (NTRS)
Burger, P.
1974-01-01
The basic operational characteristics of dc-to-dc converters are analyzed along with the basic physical characteristics of power converters. A simple class of dc-to-dc power converters are chosen which could satisfy any set of operating requirements, and three different controlling methods in this class are described in detail. Necessary conditions for the stability of these converters are measured through analog computer simulation whose curves are related to other operational characteristics, such as ripple and regulation. Further research is suggested for the solution of absolute stability and efficient physical design of this class of power converters.
Kaminsky, Lauren W; Sei, Janet J; Parekh, Nikhil J; Davies, Michael L; Reider, Irene E; Krouse, Tracy E; Norbury, Christopher C
2015-10-01
Viruses that spread systemically from a peripheral site of infection cause morbidity and mortality in the human population. Innate myeloid cells, including monocytes, macrophages, monocyte-derived dendritic cells (mo-DC), and dendritic cells (DC), respond early during viral infection to control viral replication, reducing virus spread from the peripheral site. Ectromelia virus (ECTV), an orthopoxvirus that naturally infects the mouse, spreads systemically from the peripheral site of infection and results in death of susceptible mice. While phagocytic cells have a requisite role in the response to ECTV, the requirement for individual myeloid cell populations during acute immune responses to peripheral viral infection is unclear. In this study, a variety of myeloid-specific depletion methods were used to dissect the roles of individual myeloid cell subsets in the survival of ECTV infection. We showed that DC are the primary producers of type I interferons (T1-IFN), requisite cytokines for survival, following ECTV infection. DC, but not macrophages, monocytes, or granulocytes, were required for control of the virus and survival of mice following ECTV infection. Depletion of either plasmacytoid DC (pDC) alone or the lymphoid-resident DC subset (CD8α(+) DC) alone did not confer lethal susceptibility to ECTV. However, the function of at least one of the pDC or CD8α(+) DC subsets is required for survival of ECTV infection, as mice depleted of both populations were susceptible to ECTV challenge. The presence of at least one of these DC subsets is sufficient for cytokine production that reduces ECTV replication and virus spread, facilitating survival following infection. Prior to the eradication of variola virus, the orthopoxvirus that causes smallpox, one-third of infected people succumbed to the disease. Following successful eradication of smallpox, vaccination rates with the smallpox vaccine have significantly dropped. There is now an increasing incidence of zoonotic orthopoxvirus infections for which there are no effective treatments. Moreover, the safety of the smallpox vaccine is of great concern, as complications may arise, resulting in morbidity. Like many viruses that cause significant human diseases, orthopoxviruses spread from a peripheral site of infection to become systemic. This study elucidates the early requirement for innate immune cells in controlling a peripheral infection with ECTV, the causative agent of mousepox. We report that there is redundancy in the function of two innate immune cell subsets in controlling virus spread early during infection. The viral control mediated by these cell subsets presents a potential target for therapies and rational vaccine design. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Hancock, David G; Shklovskaya, Elena; Guy, Thomas V; Falsafi, Reza; Fjell, Chris D; Ritchie, William; Hancock, Robert E W; Fazekas de St Groth, Barbara
2014-01-01
Dendritic cells (DCs) are critical for regulating CD4 and CD8 T cell immunity, controlling Th1, Th2, and Th17 commitment, generating inducible Tregs, and mediating tolerance. It is believed that distinct DC subsets have evolved to control these different immune outcomes. However, how DC subsets mount different responses to inflammatory and/or tolerogenic signals in order to accomplish their divergent functions remains unclear. Lipopolysaccharide (LPS) provides an excellent model for investigating responses in closely related splenic DC subsets, as all subsets express the LPS receptor TLR4 and respond to LPS in vitro. However, previous studies of the LPS-induced DC transcriptome have been performed only on mixed DC populations. Moreover, comparisons of the in vivo response of two closely related DC subsets to LPS stimulation have not been reported in the literature to date. We compared the transcriptomes of murine splenic CD8 and CD11b DC subsets after in vivo LPS stimulation, using RNA-Seq and systems biology approaches. We identified subset-specific gene signatures, which included multiple functional immune mediators unique to each subset. To explain the observed subset-specific differences, we used a network analysis approach. While both DC subsets used a conserved set of transcription factors and major signalling pathways, the subsets showed differential regulation of sets of genes that 'fine-tune' the network Hubs expressed in common. We propose a model in which signalling through common pathway components is 'fine-tuned' by transcriptional control of subset-specific modulators, thus allowing for distinct functional outcomes in closely related DC subsets. We extend this analysis to comparable datasets from the literature and confirm that our model can account for cell subset-specific responses to LPS stimulation in multiple subpopulations in mouse and man.
Paez-Ribes, Marta; Man, Shan; Xu, Ping; Kerbel, Robert S
2015-12-15
To resolve a controversy involving the therapeutic impact of antiangiogenic drugs and particularly antibodies targeting the VEGF pathway, namely, a body of preclinical mouse therapy studies showing such drugs can promote invasion and/or distant metastasis when used as monotherapies. In contrast, clinical studies have not shown such promalignancy effects. However, most such clinical studies have involved patients also treated with concurrent chemotherapy highlighting the possibility that chemotherapy may prevent any potential promalignancy effect caused by an antiangiogenic drug treatment. The impact of antiangiogenic therapy using DC101, an antibody targeting mouse VEGFR-2 with or without concurrent chemotherapy was assessed in multiple human breast cancer xenograft models, where impact on orthotopic primary tumors was evaluated. Metastasis was also assessed during adjuvant and neoadjuvant plus adjuvant therapy, after surgical resection of primary tumors, with the same combination therapies. Antiangiogenic therapy, while blunting tumor volume growth, was found to increase local invasion in multiple primary tumor models, including a patient-derived xenograft, but this effect was blocked by concurrent chemotherapy. Similarly, the combination of paclitaxel with DC101 caused a marked reduction of micro- or macrometastatic disease in contrast to DC101 monotherapy, which was associated with small increases in metastatic disease. Conventional wisdom is that targeted biologic antiangiogenic agents such as bevacizumab when used with chemotherapy increase the efficacy of the chemotherapy treatment. Our results suggest the reverse may be true as well-chemotherapy may improve the impact of antiangiogenic drug treatment and, as a result, overall efficacy. Clin Cancer Res; 21(24); 5488-98. ©2015 AACR. ©2015 American Association for Cancer Research.
Ein-Gar, Danit; Steinhart, Yael
2017-01-01
Self-efficacy constitutes a key factor that influences people's inclination to engage in effortful tasks. In this study, we focus on an interesting interplay between two prominent factors known to influence engagement in effortful tasks: the timing of the task (i.e., whether the task is scheduled to take place in the near or distant future) and individuals' levels of self-control. Across three studies, we show that these two factors have an interacting effect on self-efficacy. Low self-control (LSC) individuals report higher self-efficacy for distant-future effortful tasks than for near-future tasks, whereas high self-control (HSC) individuals report higher self-efficacy for near-future tasks than for distant future tasks. We further demonstrate how self-efficacy then molds individuals' willingness to engage in those effortful tasks. Given that a particular task may comprise effortful aspects alongside more enjoyable aspects, we show that the effects we observe emerge with regard to a task whose effortful aspects are salient and that the effects are eliminated when the enjoyable aspects of that same task are highlighted. PMID:29075225
Fuzzy control of power converters based on quasilinear modelling
NASA Astrophysics Data System (ADS)
Li, C. K.; Lee, W. L.; Chou, Y. W.
1995-03-01
Unlike feedback control by the fuzzy PID method, a new fuzzy control algorithm based on quasilinear modelling of the DC-DC converter is proposed. Investigation is carried out using a buck-boost converter. Simulation results demonstrated that the converter can be regulated with improved performance even when subjected to input disturbance and load variation.
Trade Electricity. Motors & Controls--Level 3. Standardized Curriculum.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Office of Occupational and Career Education.
This curriculum guide consists of seven modules on motors and controls, one of the three divisions of the standardized trade electricity curriculum in high schools in New York City. The seven modules cover the following subjects: energy conservation wiring, direct current (DC) motor repair and rewinding, DC motor controls, alternating current (AC)…
Low-Cost Undergraduate Control Systems Experiments Using Microcontroller-Based Control of a DC Motor
ERIC Educational Resources Information Center
Gunasekaran, M.; Potluri, R.
2012-01-01
This paper presents low-cost experiments for a control systems laboratory module that is worth one and a third credits. The experiments are organized around the microcontroller-based control of a permanent magnet dc motor. The experimental setups were built in-house. Except for the operating system, the software used is primarily freeware or free…
NASA Technical Reports Server (NTRS)
Rippel, W. E.; Edwards, D. B.
1984-01-01
Commutation by field-effect transistor allows more efficient operation. High voltage field-effect transistor (FET) controls silicon controlled rectifiers (SCR's). Circuit requires only one capacitor and one inductor in commutation circuit: simpler, more efficient, and more economical than conventional inverters. Adaptable to dc-to-dc converters.
Description of the SSF PMAD DC testbed control system data acquisition function
NASA Technical Reports Server (NTRS)
Baez, Anastacio N.; Mackin, Michael; Wright, Theodore
1992-01-01
The NASA LeRC in Cleveland, Ohio has completed the development and integration of a Power Management and Distribution (PMAD) DC Testbed. This testbed is a reduced scale representation of the end to end, sources to loads, Space Station Freedom Electrical Power System (SSF EPS). This unique facility is being used to demonstrate DC power generation and distribution, power management and control, and system operation techniques considered to be prime candidates for the Space Station Freedom. A key capability of the testbed is its ability to be configured to address system level issues in support of critical SSF program design milestones. Electrical power system control and operation issues like source control, source regulation, system fault protection, end-to-end system stability, health monitoring, resource allocation, and resource management are being evaluated in the testbed. The SSF EPS control functional allocation between on-board computers and ground based systems is evolving. Initially, ground based systems will perform the bulk of power system control and operation. The EPS control system is required to continuously monitor and determine the current state of the power system. The DC Testbed Control System consists of standard controllers arranged in a hierarchical and distributed architecture. These controllers provide all the monitoring and control functions for the DC Testbed Electrical Power System. Higher level controllers include the Power Management Controller, Load Management Controller, Operator Interface System, and a network of computer systems that perform some of the SSF Ground based Control Center Operation. The lower level controllers include Main Bus Switch Controllers and Photovoltaic Controllers. Power system status information is periodically provided to the higher level controllers to perform system control and operation. The data acquisition function of the control system is distributed among the various levels of the hierarchy. Data requirements are dictated by the control system algorithms being implemented at each level. A functional description of the various levels of the testbed control system architecture, the data acquisition function, and the status of its implementationis presented.
Aboughalma, Hanssan; Bi, Ran; Schlaak, Michael
2008-07-01
The use of a combination of electrokinetic remediation and phytoremediation to decontaminate soil polluted with heavy metals has been demonstrated in a laboratory-scale experiment. Potato tubers were planted in plastic vessels filled with Zn, Pb, Cu and Cd contaminated soil and grown in a greenhouse. Three of these vessels were treated with direct current electric field (DC), three with alternative current (AC) and three remained untreated as control vessels. The soil pH varied from anode to cathode with a minimum of pH 3 near the anode and a maximum of pH 8 near the cathode in the DC treated soil profile. There was an accumulation of Zn, Cu and Cd at about 12 cm distance from anode when soil pH was 5 in the DC treated soil profile. There was no significant metal redistribution and pH variation between anode and cathode in the AC soil profile. The biomass production of the plants was 72% higher under AC treatment and 27% lower under DC treatment compared to the control. Metal accumulation was generally higher in the plant roots treated with electrical fields than the control. The overall metal uptake in plant shoots was lower under DC treatment compared to AC treatment and control, although there was a higher accumulation of Zn and Cu in the plant roots treated with electrical fields. The Zn uptake in plant shoots under AC treatment was higher compared to the control and DC treatment. Zn and Cu accumulation in the plant roots under AC and DC treatment was similar, and both were higher comparing to control. Cd content in plant roots under all three treatments was found to be higher than that in the soil. The Pb accumulation in the roots and the uptake into the shoots was lower compared to its content in the soil.
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Ali, Zeina
Dendritic cells (DC) are known to play a major role during contact allergy induced by contact sensitizers (CS). Our previous studies showed that Nrf2 was induced in DC and controlled allergic skin inflammation in mice in response to chemicals. In this work, we raised the question of the role of Nrf2 in response to a stress provoked by chemical sensitizers in DC. We used two well-described chemical sensitizers, dinitrochlorobenzene (DNCB) and cinnamaldehyde (CinA), known to have different chemical reactivity and mechanism of action. First, we performed a RT-qPCR array showing that CinA was a higher inducer of immune and detoxificationmore » genes compared to DNCB. Interestingly, in the absence of Nrf2, gene expression was dramatically affected in response to DNCB but was slightly affected in response to CinA. These observations prompted us to study DC's cell death in response to both chemicals. DNCB and CinA increased apoptotic cells and decreased living cells in the absence of Nrf2. The characterization of DC apoptosis induced by both CS involved the mitochondrial-dependent caspase pathway and was regulated via Nrf2 in response to both chemicals. Oxidative stress induced by DNCB, and leading to cell death, was regulated by Nrf2. Unlike CinA, DNCB treatment provoked a significant reduction of intracellular GSH levels and up-regulated bcl-2 gene expression, under the control of Nrf2. This work underlies that chemical reactivity may control Nrf2-dependent gene expression leading to different cytoprotective mechanisms in DC. - Highlights: • Nrf2 controls cell death induced by contact sensitizers in dendritic cells. • DNCB reduced GSH levels and up-regulated bcl-2 gene expression unlike CinA. • Chemical reactivity controls Nrf2-dependent genes having protective effect in DC.« less
NASA Astrophysics Data System (ADS)
Grainger, Brandon Michael
The growth in the electric power industry's portfolio of Direct Current (DC) based generation and loads have captured the attention of many leading research institutions. Opportunities for using DC based systems have been explored in electric ship design and have been a proven, reliable solution for transmitting bulk power onshore and offshore. To integrate many of the renewable resources into our existing AC grid, a number of power conversions through power electronics are required to condition the equipment for direct connection. Within the power conversion stages, there is always a requirement to convert to or from DC. The AC microgrid is a conceptual solution proposed for integrating various types of renewable generation resources. The fundamental microgrid requirements include the capability of operating in islanding mode and/or grid connected modes. The technical challenges associated with microgrids include (1) operation modes and transitions that comply with IEEE1547 without extensive custom engineering and (2) control architecture and communication. The Medium Voltage DC (MVDC) architecture, explored by the University of Pittsburgh, can be visualized as a special type of DC microgrid. This dissertation is multi-faceted, focused on many design aspects of an offshore DC microgrid. The focal points of the discussion are focused on optimized high power, high frequency magnetic material performance in electric machines, transformers, and DC/DC power converters---all components found within offshore, power system architectures. A new controller design based upon model reference control is proposed and shown to stabilize the electric motor drives (modeled as constant power loads), which serve as the largest power consuming entities in the microgrid. The design and simulation of a state-of-the-art multilevel converter for High Voltage DC (HVDC) is discussed and a component sensitivity analysis on fault current peaks is explored. A power management routine is proposed and evaluated as the DC microgrid is disturbed through various mode transitions. Finally, two communication protocols are described for the microgrid---one to minimize communication overhead inside the microgrid and another to provide robust and scalable intra-grid communication. The work presented is supported by Asea Brown Boveri (ABB) Corporate Research Center within the Active Grid Infrastructure program, the Advanced Research Project Agency - Energy (ARPA-E) through the Solar ADEPT program, and Mitsubishi Electric Corporation (MELCO).
Development, Integration and Testing of Automated Triggering Circuit for Hybrid DC Circuit Breaker
NASA Astrophysics Data System (ADS)
Kanabar, Deven; Roy, Swati; Dodiya, Chiragkumar; Pradhan, Subrata
2017-04-01
A novel concept of Hybrid DC circuit breaker having combination of mechanical switch and static switch provides arc-less current commutation into the dump resistor during quench in superconducting magnet operation. The triggering of mechanical and static switches in Hybrid DC breaker can be automatized which can effectively reduce the overall current commutation time of hybrid DC circuit breaker and make the operation independent of opening time of mechanical switch. With this view, a dedicated control circuit (auto-triggering circuit) has been developed which can decide the timing and pulse duration for mechanical switch as well as static switch from the operating parameters. This circuit has been tested with dummy parameters and thereafter integrated with the actual test set up of hybrid DC circuit breaker. This paper deals with the conceptual design of the auto-triggering circuit, its control logic and operation. The test results of Hybrid DC circuit breaker using this circuit have also been discussed.
Transient analysis of an HTS DC power cable with an HVDC system
NASA Astrophysics Data System (ADS)
Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun; Yang, Byeongmo
2013-11-01
The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.
Shimer, D.W.; Lange, A.C.
1995-05-23
A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.
Shimer, Daniel W.; Lange, Arnold C.
1995-01-01
A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.
NASA Astrophysics Data System (ADS)
Zhang, Mingyang
2018-06-01
To further study the bidirectional flow problem of V2G (Vehicle to Grid) charge and discharge motor, the mathematical model of AC/DC converter and bi-directional DC/DC converter was established. Then, lithium battery was chosen as the battery of electric vehicle and its mathematical model was established. In order to improve the service life of lithium battery, bidirectional DC/DC converter adopted constant current and constant voltage control strategy. In the initial stage of charging, constant current charging was adopted with current single closed loop control. After reaching a certain value, voltage was switched to constant voltage charging controlled by voltage and current. Subsequently, the V2G system simulation model was built in MATLAB/Simulink. The simulation results verified the correctness of the control strategy and showed that when charging, constant current and constant voltage charging was achieved, the grid side voltage and current were in the same phase, and the power factor was about 1. When discharging, the constant current discharge was applied, and the grid voltage and current phase difference was r. To sum up, the simulation results are correct and helpful.
History of the Innovation of Damage Control for Management of Trauma Patients: 1902-2016.
Roberts, Derek J; Ball, Chad G; Feliciano, David V; Moore, Ernest E; Ivatury, Rao R; Lucas, Charles E; Fabian, Timothy C; Zygun, David A; Kirkpatrick, Andrew W; Stelfox, Henry T
2017-05-01
To review the history of the innovation of damage control (DC) for management of trauma patients. DC is an important development in trauma care that provides a valuable case study in surgical innovation. We searched bibliographic databases (1950-2015), conference abstracts (2009-2013), Web sites, textbooks, and bibliographies for articles relating to trauma DC. The innovation of DC was then classified according to the Innovation, Development, Exploration, Assessment, and Long-term study model of surgical innovation. The "innovation" of DC originated from the use of therapeutic liver packing, a practice that had previously been abandoned after World War II because of adverse events. It then "developed" into abbreviated laparotomy using "rapid conservative operative techniques." Subsequent "exploration" resulted in the application of DC to increasingly complex abdominal injuries and thoracic, peripheral vascular, and orthopedic injuries. Increasing use of DC laparotomy was followed by growing reports of postinjury abdominal compartment syndrome and prophylactic use of the open abdomen to prevent intra-abdominal hypertension after DC laparotomy. By the year 2000, DC surgery had been widely adopted and was recommended for use in surgical journals, textbooks, and teaching courses ("assessment" stage of innovation). "Long-term study" of DC is raising questions about whether the procedure should be used more selectively in the context of improving resuscitation practices. The history of the innovation of DC illustrates how a previously abandoned surgical technique was adapted and readopted in response to an increased understanding of trauma patient physiology and changing injury patterns and trauma resuscitation practices.
Microcomputer control of an electronically commutated dc motor
NASA Astrophysics Data System (ADS)
El-Sharkawi, M. A.; Coleman, J. S.; Mehdi, I. S.; Sommer, D. L.
A microcomputer control system for an electronically commutated dc motor (ECM) has been designed, built and tested. A 3-hp, 270-volt, samarium-cobalt brushless dc motor is controlled by an Intel 8086-based microcomputer. The main functions of the microcomputer are to control the speed of the motor, to provide forward or reverse rotation, to brake, and to protect the motor and its power electronic switching circuits from overcurrents. The necessary interface circuits were designed and built, and the system components have been integrated and tested. It is shown that the proposed ECM system with the microcomputer control operate the motor reliably over a wide range of speeds. The purpose of this effort is to develop the motorcontroller for driving electromechanical actuators for flight control and other aircraft applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Shaohua, E-mail: hua66com@163.com; School of Automation, Chongqing University, Chongqing 400044; Hou, Zhiwei
2015-12-15
In this paper, chaos control is proposed for the output- constrained system with uncertain control gain and time delay and is applied to the brushless DC motor. Using the dynamic surface technology, the controller overcomes the repetitive differentiation of backstepping and boundedness hypothesis of pre-determined control gain by incorporating radial basis function neural network and adaptive technology. The tangent barrier Lyapunov function is employed for time-delay chaotic system to prevent constraint violation. It is proved that the proposed control approach can guarantee asymptotically stable in the sense of uniformly ultimate boundedness without constraint violation. Finally, the effectiveness of the proposedmore » approach is demonstrated on the brushless DC motor example.« less
NASA Astrophysics Data System (ADS)
Soreng, Bineeta; Behera, Pradyumna; Pradhan, Raseswari
2017-08-01
This paper presents model of a grid-integrated photovoltaic array with Maximum Power Point Tracker (MPPT) and voltage oriented controller. The MPPT of the PV array is usually an essential part of PV system as MPPT helps the operating point of the solar array to align its maximum power point. In this model, the MPPT along with a DC-DC converter lets a PV generator to produce continuous power, despite of the measurement conditions. The neutral-point-clamped converter (NPC) with a boost converter raises the voltage from the panels to the DC-link. An LCL-filter smoothens the current ripple caused by the PWM modulation of the grid-side inverter. In addition to the MPPT, the system has two more two controllers, such as voltage controller and a current controller. The voltage control has a PI controller to regulate the PV voltage to optimal level by controlling the amount of current injected into the boost stage. Here, the grid-side converter transfers the power from the DC-link into the grid and maintains the DC-link voltage. Three-phase PV inverters are used for off-grid or designed to create utility frequency AC. The PV system can be connected in series or parallel to get the desired output power. To justify the working of this model, the grid-integrated PV system has been designed in MATLAB/PLECS. The simulation shows the P-V curve of implemented PV Array consisting 4 X 20 modules, reactive, real power, grid voltage and current.
Sensorless Load Torque Estimation and Passivity Based Control of Buck Converter Fed DC Motor
Kumar, S. Ganesh; Thilagar, S. Hosimin
2015-01-01
Passivity based control of DC motor in sensorless configuration is proposed in this paper. Exact tracking error dynamics passive output feedback control is used for stabilizing the speed of Buck converter fed DC motor under various load torques such as constant type, fan type, propeller type, and unknown load torques. Under load conditions, sensorless online algebraic approach is proposed, and it is compared with sensorless reduced order observer approach. The former produces better response in estimating the load torque. Sensitivity analysis is also performed to select the appropriate control variables. Simulation and experimental results fully confirm the superiority of the proposed approach suggested in this paper. PMID:25893208
Boosting airway T-regulatory cells by gastrointestinal stimulation as a strategy for asthma control.
Strickland, D H; Judd, S; Thomas, J A; Larcombe, A N; Sly, P D; Holt, P G
2011-01-01
The hallmark of atopic asthma is transient airways hyperresponsiveness (AHR) preceded by aeroallergen-induced Th-cell activation. This is preceded by upregulation of CD86 on resident airway dendritic cells (DCs) that normally lack competence in T-cell triggering. Moreover, AHR duration is controlled via T-regulatory (Treg) cells, which can attenuate CD86 upregulation on DC. We show that airway mucosal Treg/DC interaction represents an accessible therapeutic target for asthma control. Notably, baseline airway Treg activity in sensitized rats can be boosted by microbe-derived stimulation of the gut, resulting in enhanced capacity to control CD86 expression on airway DC triggered by aeroallergen and accelerated resolution of AHR.
Draheim, Marion; Wlodarczyk, Myriam F; Crozat, Karine; Saliou, Jean-Michel; Alayi, Tchilabalo Dilezitoko; Tomavo, Stanislas; Hassan, Ali; Salvioni, Anna; Demarta-Gatsi, Claudia; Sidney, John; Sette, Alessandro; Dalod, Marc; Berry, Antoine; Silvie, Olivier; Blanchard, Nicolas
2017-11-01
In malaria, CD4 Th1 and T follicular helper (T FH ) cells are important for controlling parasite growth, but Th1 cells also contribute to immunopathology. Moreover, various regulatory CD4 T-cell subsets are critical to hamper pathology. Yet the antigen-presenting cells controlling Th functionality, as well as the antigens recognized by CD4 T cells, are largely unknown. Here, we characterize the MHC II immunopeptidome presented by DC during blood-stage malaria in mice. We establish the immunodominance hierarchy of 14 MHC II ligands derived from conserved parasite proteins. Immunodominance is shaped differently whether blood stage is preceded or not by liver stage, but the same ETRAMP-specific dominant response develops in both contexts. In naïve mice and at the onset of cerebral malaria, CD8α + dendritic cells (cDC1) are superior to other DC subsets for MHC II presentation of the ETRAMP epitope. Using in vivo depletion of cDC1, we show that cDC1 promote parasite-specific Th1 cells and inhibit the development of IL-10 + CD4 T cells. This work profiles the P. berghei blood-stage MHC II immunopeptidome, highlights the potency of cDC1 to present malaria antigens on MHC II, and reveals a major role for cDC1 in regulating malaria-specific CD4 T-cell responses. © 2017 The Authors. Published under the terms of the CC BY 4.0 license.
Solar Dynamic Power System Stability Analysis and Control
NASA Technical Reports Server (NTRS)
Momoh, James A.; Wang, Yanchun
1996-01-01
The objective of this research is to conduct dynamic analysis, control design, and control performance test of solar power system. Solar power system consists of generation system and distribution network system. A bench mark system is used in this research, which includes a generator with excitation system and governor, an ac/dc converter, six DDCU's and forty-eight loads. A detailed model is used for modeling generator. Excitation system is represented by a third order model. DDCU is represented by a seventh order system. The load is modeled by the combination of constant power and constant impedance. Eigen-analysis and eigen-sensitivity analysis are used for system dynamic analysis. The effects of excitation system, governor, ac/dc converter control, and the type of load on system stability are discussed. In order to improve system transient stability, nonlinear ac/dc converter control is introduced. The direct linearization method is used for control design. The dynamic analysis results show that these controls affect system stability in different ways. The parameter coordination of controllers are recommended based on the dynamic analysis. It is concluded from the present studies that system stability is improved by the coordination of control parameters and the nonlinear ac/dc converter control stabilize system oscillation caused by the load change and system fault efficiently.
Decoy receptor 3 enhances tumor progression via induction of tumor-associated macrophages.
Tai, Shyh-Kuan; Chang, Hsin-Chuan; Lan, Keng-Li; Lee, Chun-Ting; Yang, Chih-Ya; Chen, Nien-Jung; Chou, Teh-Ying; Tarng, Der-Cherng; Hsieh, Shie-Liang
2012-03-01
Tumor-associated macrophages (TAMs) are the major component of tumor-infiltrating leukocytes. TAMs are heterogeneous, with distinct phenotypes influenced by the microenvironment surrounding tumor tissues. Decoy receptor 3 (DcR3), a member of the TNFR superfamily, is overexpressed in tumor cells and is capable of modulating host immunity as either a neutralizing decoy receptor or an effector molecule. Upregulation of DcR3 has been observed to correlate with a poor prognosis in various cancers. However, the mechanisms underlying the DcR3-mediated tumor-promoting effect remain unclear. We previously demonstrated that DcR3 modulates macrophage activation toward an M2-like phenotype in vitro and that DcR3 downregulates MHC class II expression in TAMs via epigenetic control. To investigate whether DcR3 promotes tumor growth, CT26-DcR3 stable transfectants were established. Compared with the vector control clone, DcR3-transfectants grew faster and resulted in TAM infiltration. We further generated CD68 promoter-driven DcR3 transgenic (Tg) mice to investigate tumor growth in vivo. Compared with wild-type mice, macrophages isolated from DcR3-Tg mice displayed higher levels of IL-10, IL-1ra, Ym1, and arginase activity, whereas the expression of IL-12, TNF-α, IL-6, NO, and MHC class II was downregulated. Significantly enhanced tumor growth and spreading were observed in DcR3-Tg mice, and the enhanced tumor growth was abolished by arginase inhibitor N-ω-hydroxy-l-norarginine and histone deacetylase inhibitor sodium valproate. These results indicated that induction of TAMs is an important mechanism for DcR3-mediated tumor progression. Our findings also suggest that targeting DcR3 might help in the development of novel treatment strategies for tumors with high DcR3 expression.
Degree of conversion of two lingual retainer adhesives cured with different light sources.
Usümez, Serdar; Büyükyilmaz, Tamer; Karaman, Ali Ihya; Gündüz, Beniz
2005-04-01
The aim of this study was to evaluate the degree of conversion (DC) of two lingual retainer adhesives, Transbond Lingual Retainer (TLR) and Light Cure Retainer (LCR), cured with a fast halogen light, a plasma arc light and a light-emitting diode (LED) at various curing times. A conventional halogen light served as the control. One hundred adhesive samples (five per group) were cured for 5, 10 or 15 seconds with an Optilux 501 (fast halogen light), for 3, 6 or 9 seconds with a Power Pac (plasma arc light), or for 10, 20 or 40 seconds with an Elipar Freelight (LED). Samples cured for 40 seconds with the conventional halogen lamp were used as the controls. Absorbance peaks were recorded using Fourier transform infrared (FT-IR) spectroscopy. DC values were calculated. Data were analysed using Kruskal-Wallis and Mann-Whitney U-tests. For the TLR, the highest DC values were achieved in 6 and 9 seconds with the plasma arc light. Curing with the fast halogen light for 15 seconds and with the LED for 40 seconds produced statistically similar DC values, but these were lower than those with the plasma arc light. All of these light exposures yielded a statistically significantly higher DC than 40 seconds of conventional halogen light curing. The highest DC value for the LCR was achieved in 15 seconds with the fast halogen light, then the plasma arc light curing for 6 seconds. These two combinations produced a statistically significantly higher DC when compared with the 40 seconds of conventional halogen light curing. The lowest DC for the LCR was achieved with 10 seconds of LED curing. The overall DC of the LCR was significantly higher than that of the TLR. The results suggest that a similar or higher DC than the control values could be achieved in 6-9 seconds by plasma arc curing, in 10-15 seconds by fast halogen curing or in 20 seconds by LED curing.
Liu, Jinlin; Zhao, Zhao; Zou, Yuqiong; Zhang, Mei; Zhou, Yonglie; Li, Yasong; Pang, Zhenzhen; Jin, Weidong
2015-05-01
Previous studies suggested a pathological role for the death decoy receptor 3 (DcR3) in systemic lupus erythematosus (SLE) and rheumatic arthritis (RA). Herein, the expression of DcR3 in primary Sjögren's syndrome (pSS) and the relationship with clinical characteristics were investigated. The serum DcR3 levels of pSS patients and healthy controls were measured by ELISA. Pearson's correlation analysis was used to evaluate the relationship between the DcR3 levels with the clinical characterstics of pSS patients. Additionally, the DcR3 expression in salivary glands of pSS patients was investigated by the immunohistochemistry method. The serum DcR3 expression in pSS patients was significantly higher than healthy controls (p < 0.001), especially in new onset pSS patients (p = 0.036). Moreover, Pearson's correlation analysis show that DcR3 levels were positively correlated with age (p = 0.013), platelet (PLT) (p = 0.002), hemoglobin (Hb) (p = 0.004), Sjögren's syndrome disease damage activity index (SSDAI) score (p = 0.005), Sjögren's syndrome disease damage index (SSDDI) score (p < 0.001) and EULAR Sjögren's syndrome disease activity index (ESSDAI) score (p = 0.010). Furthermore, the DcR3 levels were significantly lower when the pSS patients were treated with the disease-modifying anti-rheumatic drugs. At last, DcR3 expression in salivary glands of pSS patients was significantly higher than healthy controls. The DcR3 expression was significantly elevated in the pSS patients and positively correlated with the clinical characteristics, and it might be an important factor involved in the progression of pSS patients and could be a potential therapeutic target.
Arıcıgil, Mitat; Dündar, Mehmet Akif; Yücel, Abitter; Arbağ, Hamdi; Aziz, Suhayb Kuria
This study aimes to evaluate platelet and leucocyte indicators, such as the mean platelet volume, platelet distribution width, plateletcrit, white blood cell count, neutrophil to lymphocyte ratio in nasopharyngeal cancer patients and also to evaluate the relationship between these indicators and nasopharyngeal cancer with distant metastasis. The medical records of 118 patients diagnosed with nasopharyngeal cancer in our hospital between January 2006 and August 2015 were reviewed. The nasopharyngeal cancer group was further sub grouped according to the presence or absence of distant metastasis and TNM (tumour - T, node - N, metastasis - M) classification. A control group consisted of 120 healthy patients. The platelet and leucocyte values at the time of the initial diagnosis were recorded. Neutrophil to lymphocyte ratio and platelet distribution width values were significantly higher in the nasopharyngeal cancer group. But only platelet distribution width values were significantly higher in the nasopharyngeal cancer group with distant metastasis compared to the nasopharyngeal cancer group without distant metastasis. Neutrophil to lymphocyte ratio and platelet distribution width values may increase in nasopharyngeal cancer. But only the platelet distribution width values may give us an idea about the distant metastasis in nasopharyngeal cancer.
NASA Technical Reports Server (NTRS)
Edie, P. C.
1981-01-01
Both straight and chopped dc motor performance data for a General Electric 5BY436A1 motor with a General Electric EV-1 controller is presented in tabular and graphical formats. Effects of motor temperature and operating voltage are also shown. The maximum motor efficiency is approximately 85% at low operating temperatures in the straight dc mode. Chopper efficiency can be assumed to be 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight mode.
Early Oscillation Detection for DC/DC Converter Fault Diagnosis
NASA Technical Reports Server (NTRS)
Wang, Bright L.
2011-01-01
The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Debraj; Das, Subhrajit; Arunkumar, G.; Elangovan, D.; Ragunath, G.
2017-11-01
In this paper a current fed interleaved DC - DC boost converter which has an isolated topology and used for high voltage step up is proposed. A basic DC to DC boost converter converts uncontrolled DC voltage into controlled DC voltage of higher magnitude. Whereas this topology has the advantages of lower input current ripple, lesser output voltage, lesser stress on switches, faster transient response, improved reliability and much lesser electromagnetic emission over the conventional DC to DC boost converter. Most important benefit of this interleaved DC to DC boost converter is much higher efficiency. The input current is divided into two paths, substantially ohmic loss (I2R) and inductor ac loss gets reduced and finally the system achieves much higher efficiency. With recent mandates on energy saving interleaved DC to DC boost converter may be used as a very powerful tool to maintain good power density keeping the input current manageable. Higher efficiency also allows higher switching frequency and as a result the topology becomes more compact and cost friendly. The proposed topology boosts 48v DC to 200 V DC. Switching frequency is 100 kHz and PSIM 9.1 Platform has been used for the simulation.
Controllable Bidirectional dc Power Sources For Large Loads
NASA Technical Reports Server (NTRS)
Tripp, John S.; Daniels, Taumi S.
1995-01-01
System redesigned for greater efficiency, durability, and controllability. Modern electronically controlled dc power sources proposed to supply currents to six electromagnets used to position aerodynamic test model in wind tunnel. Six-phase bridge rectifier supplies load with large current at voltage of commanded magnitude and polarity. Current-feedback circuit includes current-limiting feature giving some protection against overload.
Modeling, Development and Control of Multilevel Converters for Power System Application =
NASA Astrophysics Data System (ADS)
Vahedi, Hani
The main goal of this project is to develop a multilevel converter topology to be useful in power system applications. Although many topologies are introduced rapidly using a bunch of switches and isolated dc sources, having a single-dc-source multilevel inverter is still a matter of controversy. In fact, each isolated dc source means a bulky transformer and a rectifier that have their own losses and costs forcing the industries to avoid entering in this topic conveniently. On the other hand, multilevel inverters topologies with single-dc-source require associated controllers to regulate the dc capacitors voltages in order to have multilevel voltage waveform at the output. Thus, a complex controller would not interest investors properly. Consequently, developing a single-dc-source multilevel inverter topology along with a light and reliable voltage control is still a challenging topic to replace the 2-level inverters in the market effectively. The first effort in this project was devoted to the PUC7 inverter to design a simple and yet efficient controller. A new modelling is performed on the PUC7 inverter and it has been simplified to first order system. Afterwards, a nonlinear cascaded controller is designed and applied to regulate the capacitor voltage at 1/3 of the DC source amplitude and to generate 7 identical voltage levels at the output supplying different type of loads such as RL or rectifier harmonic ones. In next work, the PUC5 topology is proposed as a remedy to the PUC7 that requires a complicated controller to operate properly. The capacitor voltage is regulated at half of dc source amplitude to generate 5 voltage levels at the output. Although the 7-level voltage waveform is replaced by a 5-level one in PUC5 topology, it is shown that the PUC5 needs a very simple and reliable voltage balancing technique due to having some redundant switching states. Moreover, a sensor-less voltage balancing technique is designed and implemented on the PUC5 inverter successfully to work in both stand-alone and gridconnected mode of operation. Eventually, a modified configuration of the PUC5 topology is presented to work as a buck PFC rectifier. The internal performance of the rectifier is like a buck converter to generate stepped down DC voltages at the two output terminals while the grid sees a boost converter externally. As well, a decoupled voltage/current controller is designed and applied to balance the output voltages identically and synchronize the input current with grid voltage to have a PFC operation acceptably. A power balance analysis is done to show the load variation range limit. All the theoretical and simulation studies are validated by experimental results completely.
An Optimal Current Observer for Predictive Current Controlled Buck DC-DC Converters
Min, Run; Chen, Chen; Zhang, Xiaodong; Zou, Xuecheng; Tong, Qiaoling; Zhang, Qiao
2014-01-01
In digital current mode controlled DC-DC converters, conventional current sensors might not provide isolation at a minimized price, power loss and size. Therefore, a current observer which can be realized based on the digital circuit itself, is a possible substitute. However, the observed current may diverge due to the parasitic resistors and the forward conduction voltage of the diode. Moreover, the divergence of the observed current will cause steady state errors in the output voltage. In this paper, an optimal current observer is proposed. It achieves the highest observation accuracy by compensating for all the known parasitic parameters. By employing the optimal current observer-based predictive current controller, a buck converter is implemented. The converter has a convergently and accurately observed inductor current, and shows preferable transient response than the conventional voltage mode controlled converter. Besides, costs, power loss and size are minimized since the strategy requires no additional hardware for current sensing. The effectiveness of the proposed optimal current observer is demonstrated experimentally. PMID:24854061
Zafirova, Biljana; This, Sébastien; Coléon, Séverin; Décembre, Elodie; Paidassi, Helena; Bouvier, Isabelle; Joubert, Pierre-Emmanuel; Duffy, Darragh; Walzer, Thierry
2018-01-01
Type I interferon (IFN-I) responses are critical for the control of RNA virus infections, however, many viruses, including Dengue (DENV) and Chikungunya (CHIKV) virus, do not directly activate plasmacytoid dendritic cells (pDCs), robust IFN-I producing cells. Herein, we demonstrated that DENV and CHIKV infected cells are sensed by pDCs, indirectly, resulting in selective IRF7 activation and IFN-I production, in the absence of other inflammatory cytokine responses. To elucidate pDC immunomodulatory functions, we developed a mouse model in which IRF7 signaling is restricted to pDC. Despite undetectable levels of IFN-I protein, pDC-restricted IRF7 signaling controlled both viruses and was sufficient to protect mice from lethal CHIKV infection. Early pDC IRF7-signaling resulted in amplification of downstream antiviral responses, including an accelerated natural killer (NK) cell-mediated type II IFN response. These studies revealed the dominant, yet indirect role of pDC IRF7-signaling in directing both type I and II IFN responses during arbovirus infections. PMID:29914621
77 FR 37827 - Airworthiness Directives; The Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-25
...) generator control unit (GCU). We are proposing this AD to prevent DC generator overvoltage events, which... proposed AD. Discussion We have received reports of direct current (DC) generator overvoltage events. The... generator and the left and right engine DC generators, and corrective actions if necessary. That AD also...
Cavity Mediated Manipulation of Distant Spin Currents Using a Cavity-Magnon-Polariton.
Bai, Lihui; Harder, Michael; Hyde, Paul; Zhang, Zhaohui; Hu, Can-Ming; Chen, Y P; Xiao, John Q
2017-05-26
Using electrical detection of a strongly coupled spin-photon system comprised of a microwave cavity mode and two magnetic samples, we demonstrate the long distance manipulation of spin currents. This distant control is not limited by the spin diffusion length, instead depending on the interplay between the local and global properties of the coupled system, enabling systematic spin current control over large distance scales (several centimeters in this work). This flexibility opens the door to improved spin current generation and manipulation for cavity spintronic devices.
Influence of DC-biasing on the performance of graphene spin valve
NASA Astrophysics Data System (ADS)
Iqbal, Muhammad Zahir; Hussain, Ghulam; Siddique, Salma; Hussain, Tassadaq; Iqbal, Muhammad Javaid
2018-04-01
Generating and controlling the spin valve signal are key factors in 'spintronics', which aims to utilize the spin degree of electrons. For this purpose, spintronic devices are constructed that can detect the spin signal. Here we investigate the effect of direct current (DC) on the magnetoresistance (MR) of graphene spin valve. The DC input not only decreases the magnitude of MR but also distorts the spin valve signal at higher DC inputs. Also, low temperature measurements revealed higher MR for the device, while the magnitude is noticed to decrease at higher temperatures. Furthermore, the spin polarization associated with NiFe electrodes is continuously increased at low DC bias and low temperatures. We also demonstrate the ohmic behavior of graphene spin valve by showing linear current-voltage (I-V) characteristics of the junction. Our findings may contribute significantly in modulating and controlling the spin transport properties of vertical spin valve structures.
Zahorchak, Alan F; Macedo, Camila; Hamm, David E; Butterfield, Lisa H; Metes, Diana M; Thomson, Angus W
2018-01-01
Human regulatory dendritic cells (DCreg) were generated from CD14 immunobead-purified or elutriated monocytes in the presence of vitamin D3 and IL-10. They exhibited similar, low levels of costimulatory CD80 and CD86, but comparatively high levels of co-inhibitory programed death ligand-1 (PD-L1) and IL-10 production compared to control immature DC (iDC). Following Toll-like receptor 4 ligation, unlike control iDC, DCreg resisted phenotypic and functional maturation and further upregulated PD-L1:CD86 expression. Whereas LPS-stimulated control iDC (mature DC; matDC) secreted pro-inflammatory tumor necrosis factor but no IL-10, the converse was observed for LPS-stimulated DCreg. DCreg weakly stimulated naïve and memory allogeneic CD4 + and CD8 + T cell proliferation and IFNγ, IL-17A and perforin/granzyme B production in MLR. Their stimulatory function was enhanced however, by blocking PD-1 ligation. High-throughput T cell receptor (TCR) sequencing revealed that, among circulating T cell subsets, memory CD8 + T cells contained the most alloreactive TCR clonotypes and that, while matDC expanded these alloreactive memory CD8 TCR clonotypes, DCreg induced more attenuated responses. These findings demonstrate the feasibility of generating highly-purified GMP-grade DCreg for systemic infusion, their influence on the alloreactive T cell response, and a key mechanistic role of the PD1 pathway. Copyright © 2017 Elsevier Inc. All rights reserved.
Analysis of a dc bus system with a nonlinear constant power load and its delayed feedback control.
Konishi, Keiji; Sugitani, Yoshiki; Hara, Naoyuki
2014-02-01
This paper tackles a destabilizing problem of a direct-current (dc) bus system with constant power loads, which can be considered a fundamental problem of dc power grid networks. The present paper clarifies scenarios of the destabilization and applies the well-known delayed-feedback control to the stabilization of the destabilized bus system on the basis of nonlinear science. Further, we propose a systematic procedure for designing the delayed feedback controller. This controller can converge the bus voltage exactly on an unstable operating point without accurate information and can track it using tiny control energy even when a system parameter, such as the power consumption of the load, is slowly varied. These features demonstrate that delayed feedback control can be considered a strong candidate for solving the destabilizing problem.
Meyer, John D; O'Campo, Patricia; Warren, Nicolas; Muntaner, Carles
2017-02-01
We assessed longitudinal patterns of effort-reward imbalance (ERI) and demand-control (DC) scores in pregnancy, and their association with newborn birthweight (BW). Sixty-one women were surveyed four times across pregnancy using the ERI and DC questionnaires. Trajectories of change in ERI and DC scores across pregnancy were constructed using growth mixture modeling, and their associations with BW were examined with generalized linear regression. Declining ERI (diminishing effort with stable/increasing reward) was associated with higher BW (408 g; P = 0.015), and was robust to other work factors. DC trajectory was not significantly associated with BW. Declining ERI may reflect improved work psychosocial climate across pregnancy, or a conscious reduction in effort. The ERI model may represent more flexible work characteristics, whereas job control may be less amenable to short-term alteration. Surveys in more diverse pregnant working populations could be recommended.
Lai, Jih-Sheng; Liu, Changrong; Ridenour, Amy
2009-04-14
DC/DC converter has a transformer having primary coils connected to an input side and secondary coils connected to an output side. Each primary coil connects a full-bridge circuit comprising two switches on two legs, the primary coil being connected between the switches on each leg, each full-bridge circuit being connected in parallel wherein each leg is disposed parallel to one another, and the secondary coils connected to a rectifying circuit. An outer loop control circuit that reduces ripple in a voltage reference has a first resistor connected in series with a second resistor connected in series with a first capacitor which are connected in parallel with a second capacitor. An inner loop control circuit that reduces ripple in a current reference has a third resistor connected in series with a fourth resistor connected in series with a third capacitor which are connected in parallel with a fourth capacitor.
Analysis of Discontinuity Induced Bifurcations in a Dual Input DC-DC Converter
NASA Astrophysics Data System (ADS)
Giaouris, Damian; Banerjee, Soumitro; Mandal, Kuntal; Al-Hindawi, Mohammed M.; Abusorrah, Abdullah; Al-Turki, Yusuf; El Aroudi, Abdelali
DC-DC power converters with multiple inputs and a single output are used in numerous applications where multiple sources, e.g. two or more renewable energy sources and/or a battery, feed a single load. In this work, a classical boost converter topology with two input branches connected to two different sources is chosen, with each branch independently being controlled by a separate peak current mode controller. We demonstrate for the first time that even though this converter is similar to other well known topologies that have been studied before, it exhibits many complex nonlinear behaviors that are not found in any other standard PWM controlled power converter. The system undergoes period incrementing cascade as a parameter is varied, with discontinuous hard transitions between consecutive periodicities. We show that the system can be described by a discontinuous map, which explains the observed bifurcation phenomena. The results have been experimentally validated.
Hua, Ming; Tao, Ming-Jie; Deng, Fu-Guo
2016-02-24
We propose a quantum processor for the scalable quantum computation on microwave photons in distant one-dimensional superconducting resonators. It is composed of a common resonator R acting as a quantum bus and some distant resonators rj coupled to the bus in different positions assisted by superconducting quantum interferometer devices (SQUID), different from previous processors. R is coupled to one transmon qutrit, and the coupling strengths between rj and R can be fully tuned by the external flux through the SQUID. To show the processor can be used to achieve universal quantum computation effectively, we present a scheme to complete the high-fidelity quantum state transfer between two distant microwave-photon resonators and another one for the high-fidelity controlled-phase gate on them. By using the technique for catching and releasing the microwave photons from resonators, our processor may play an important role in quantum communication as well.
Computerized Torque Control for Large dc Motors
NASA Technical Reports Server (NTRS)
Willett, Richard M.; Carroll, Michael J.; Geiger, Ronald V.
1987-01-01
Speed and torque ranges in generator mode extended. System of shunt resistors, electronic switches, and pulse-width modulation controls torque exerted by large, three-phase, electronically commutated dc motor. Particularly useful for motor operating in generator mode because it extends operating range to low torque and high speed.
Lu, Bin [Kenosha, WI; Luebke, Charles John [Sussex, WI; Habetler, Thomas G [Snellville, GA; Zhang, Pinjia [Atlanta, GA; Becker, Scott K [Oak Creek, WI
2011-12-27
A system and method for measuring and controlling stator winding temperature in an AC motor while idling is disclosed. The system includes a circuit having an input connectable to an AC source and an output connectable to an input terminal of a multi-phase AC motor. The circuit further includes a plurality of switching devices to control current flow and terminal voltages in the multi-phase AC motor and a controller connected to the circuit. The controller is configured to activate the plurality of switching devices to create a DC signal in an output of the motor control device corresponding to an input to the multi-phase AC motor, determine or estimate a stator winding resistance of the multi-phase AC motor based on the DC signal, and estimate a stator temperature from the stator winding resistance. Temperature can then be controlled and regulated by DC injection into the stator windings.
Demonstrative fractional order - PID controller based DC motor drive on digital platform.
Khubalkar, Swapnil W; Junghare, Anjali S; Aware, Mohan V; Chopade, Amit S; Das, Shantanu
2017-09-21
In industrial drives applications, fractional order controllers can exhibit phenomenal impact due to realization through digital implementation. Digital fractional order controllers have created wide scope as it possess the inherent advantages like robustness against the plant parameter variation. This paper provides brief design procedure of fractional order proportional-integral-derivative (FO-PID) controller through the indirect approach of approximation using constant phase technique. The new modified dynamic particle swarm optimization (IdPSO) technique is proposed to find controller parameters. The FO-PID controller is implemented using floating point digital signal processor. The building blocks are designed and assembled with all peripheral components for the 1.5kW industrial DC motor drive. The robust operation for parametric variation is ascertained by testing the controller with two separately excited DC motors with the same rating but different parameters. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Solid state light source driver establishing buck or boost operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmer, Fred
A solid state light source driver circuit that operates in either a buck convertor or a boost convertor configuration is provided. The driver circuit includes a controller, a boost switch circuit and a buck switch circuit, each coupled to the controller, and a feedback circuit, coupled to the light source. The feedback circuit provides feedback to the controller, representing a DC output of the driver circuit. The controller controls the boost switch circuit and the buck switch circuit in response to the feedback signal, to regulate current to the light source. The controller places the driver circuit in its boostmore » converter configuration when the DC output is less than a rectified AC voltage coupled to the driver circuit at an input node. The controller places the driver circuit in its buck converter configuration when the DC output is greater than the rectified AC voltage at the input node.« less
Incidence and sites of distant metastases from head and neck cancer.
Ferlito, A; Shaha, A R; Silver, C E; Rinaldo, A; Mondin, V
2001-01-01
The incidence of distant metastases in head and neck squamous cell carcinoma (SCC) is relatively small in comparison to other malignancies. Distant metastases adversely impact survival and may significantly affect treatment planning. The incidence of distant metastases is influenced by location of the primary tumor, initial T and N stage of the neoplasm, and the presence or absence of regional control above the clavicle. Patients with advanced nodal disease have a high incidence of distant metastases, particularly in the presence of jugular vein invasion or extensive soft tissue disease in the neck. Primary tumors of advanced T stages in the hypopharynx, oropharynx and oral cavity are associated with the highest incidence of distant metastases. Pulmonary metastases are the most frequent in SCC, accounting for 66% of distant metastases. It may be difficult to distinguish pulmonary metastasis from a new primary tumor, particularly if solitary. Other metastatic sites include bone (22%), liver (10%), skin, mediastinum and bone marrow. An important question remains as to how intensely pre- and postoperative screening for distant metastases should be performed. Preoperative chest X-ray is warranted in all cases. If the primary tumor and nodal status place the patient at high risk for pulmonary metastasis, then preoperative computed tomography scan of the chest should be done. Screening for distant metastases at other sites is usually not indicated in SCC of the upper aerodigestive tract. Postoperatively, annual X-rays of the chest are usually sufficient, but in high-risk situations a chest X-ray performed every 3-6 months may be beneficial. Certain histologic types of primary tumor have greater or lesser propensity to metastasize distantly, and have a different natural history. Adenoid cystic carcinoma metastasizes frequently, even in the absence of extensive local or regional disease. Basaloid squamous cell carcinoma and neuroendocrine carcinomas also metastasize widely. Extensive evaluation for distant metastases is justified for these tumors. Knowledge of the natural history of various neoplasms and the factors that contribute to distant metastases as well as good judgement are essential for cost-effective treatment planning and decision-making with regard to pre- and postoperative evaluation for distant metastases in cancer of the head and neck. Copyright 2001 S. Karger AG, Basel
Gaymalov, Zagit Z; Yang, Zhihui; Pisarev, Vladimir M; Alakhov, Valery Yu; Kabanov, Alexander V
2009-02-01
DNA vaccines can be greatly improved by polymer agents that simultaneously increase transgene expression and activate immunity. We describe here Pluronic P85 (P85), a triblock copolymer of ethylene oxide (EO) and propylene oxide (PO) EO(26)-PO(40)-EO(26). Using a mouse model we demonstrate that co-administration of a bacterial plasmid DNA with P85 in a skeletal muscle greatly increases gene expression in the injection site and distant organs, especially the draining lymph nodes and spleen. The reporter expression colocalizes with the specific markers of myocytes and keratinocytes in the muscle, as well as dendritic cells (DCs) and macrophages in the muscle, lymph nodes and spleen. Furthermore, DNA/P85 and P85 alone increase the systemic expansion of CD11c+ (DC), and local expansion of CD11c+, CD14+ (macrophages) and CD49b+ (natural killer) cell populations. DNA/P85 (but not P85) also increases maturation of local DC (CD11c+ CD86+, CD11c+ CD80 +, and CD11c+ CD40+. We suggest that DNA/P85 promotes the activation and recruitment of the antigen-presenting cells, which further incorporate, express and carry the transgene to the immune system organs.
Inverse regulatory coordination of motility and curli-mediated adhesion in Escherichia coli.
Pesavento, Christina; Becker, Gisela; Sommerfeldt, Nicole; Possling, Alexandra; Tschowri, Natalia; Mehlis, Anika; Hengge, Regine
2008-09-01
During the transition from post-exponential to stationary phase, Escherichia coli changes from the motile-planktonic to the adhesive-sedentary "lifestyle." We demonstrate this transition to be controlled by mutual inhibition of the FlhDC/motility and sigma(S)/adhesion control cascades at two distinct hierarchical levels. At the top level, motility gene expression and the general stress response are inversely coordinated by sigma(70)/sigma(FliA)/sigma(S) competition for core RNA polymerase and the FlhDC-controlled FliZ protein acting as a sigma(S) inhibitor. At a lower level, the signaling molecule bis-(3'-5')-cyclic-diguanosine monophosphate (c-di-GMP) reduces flagellar activity and stimulates transcription of csgD, which encodes an essential activator of adhesive curli fimbriae expression. This c-di-GMP is antagonistically controlled by sigma(S)-regulated GGDEF proteins (mainly YegE) and YhjH, an EAL protein and c-di-GMP phosphodiesterase under FlhDC/FliA control. The switch from motility-based foraging to the general stress response and curli expression requires sigma(S)-modulated down-regulation of expression of the flagellar regulatory cascade as well as proteolysis of the flagellar master regulator FlhDC. Control of YhjH by FlhDC and of YegE by sigma(S) produces a fine-tuned checkpoint system that "unlocks" curli expression only after down-regulation of flagellar gene expression. In summary, these data reveal the logic and sequence of molecular events underlying the motile-to-adhesive "lifestyle" switch in E. coli.
Pulse-Width-Modulating Driver for Brushless dc Motor
NASA Technical Reports Server (NTRS)
Salomon, Phil M.
1991-01-01
High-current pulse-width-modulating driver for brushless dc motor features optical coupling of timing signals from low-current control circuitry to high-current motor-driving circuitry. Provides high electrical isolation of motor-power supply, helping to prevent fast, high-current motor-driving pulses from being coupled through power supplies into control circuitry, where they interfere with low-current control signals.
Anti-control of chaos of single time-scale brushless DC motor.
Ge, Zheng-Ming; Chang, Ching-Ming; Chen, Yen-Sheng
2006-09-15
Anti-control of chaos of single time-scale brushless DC motors is studied in this paper. In order to analyse a variety of periodic and chaotic phenomena, we employ several numerical techniques such as phase portraits, bifurcation diagrams and Lyapunov exponents. Anti-control of chaos can be achieved by adding an external constant term or an external periodic term.
ERIC Educational Resources Information Center
Moritz, Steffen; Treszl, Andras; Rufer, Michael
2011-01-01
Nail-biting is currently classified as an impulse control disorder not otherwise specified. Although seldom targeted as a primary symptom, nail-biting is often associated with somatic complications and decreased quality of life. The present study assessed the effectiveness of an innovative self-help technique, titled decoupling (DC). DC aims at…
Changyong, C; Sun, M; Li, H; Brockmeyer, N; Wu, Nan Ping
2010-09-24
Dendritic cells (DC) are the initiators and modulators of the immune responses. Some species of pathogenic microorganisms have developed immune evasion strategies by controlling antigen presentation function of DC. Simian virus 40 (SV40) is a DNA tumor virus of rhesus monkey origin. It can induce cell transformation and tumorigenesis in many vertebrate species, but often causes no visible effects and persists as a latent infection in rhesus monkeys under natural conditions. To investigate the interaction between SV40 and rhesus monkey DC, rhesus monkey peripheral blood monocyte-derived DC were induced using recombinant human Interleukin-4 (rhIL-4) and infective SV40, the phenotype and function of DC-specific intracellular adhesion molecule-3 grabbing nonintegrin (DC-SIGN)(+) DC were analyzed by flow cytometry (FCM) and mixed lymphocyte reaction (MLR). Results showed that SV40 can down-regulate the expression of CD83 and CD86 on DC and impair DC-induced activation of T cell proliferation. These findings suggest that SV40 might also cause immune suppression by influencing differentiation and maturation of DC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez, Bradford A.; Mettu, Pradeep; Vajzovic, Lejla
2014-05-01
Purpose: To investigate, in the treatment of uveal melanomas, how tumor control, radiation toxicity, and visual outcomes are affected by the radiation dose at the tumor apex. Methods and Materials: A retrospective review was performed to evaluate patients treated for uveal melanoma with {sup 125}I plaques between 1988 and 2010. Radiation dose is reported as dose to tumor apex and dose to 5 mm. Primary endpoints included time to local failure, distant failure, and death. Secondary endpoints included eye preservation, visual acuity, and radiation-related complications. Univariate and multivariate analyses were performed to determine associations between radiation dose and the endpointmore » variables. Results: One hundred ninety patients with sufficient data to evaluate the endpoints were included. The 5-year local control rate was 91%. The 5-year distant metastases rate was 10%. The 5-year overall survival rate was 84%. There were no differences in outcome (local control, distant metastases, overall survival) when dose was stratified by apex dose quartile (<69 Gy, 69-81 Gy, 81-89 Gy, >89 Gy). However, increasing apex dose and dose to 5-mm depth were correlated with greater visual acuity loss (P=.02, P=.0006), worse final visual acuity (P=.02, P<.0001), and radiation complications (P<.0001, P=.0009). In addition, enucleation rates were worse with increasing quartiles of dose to 5 mm (P=.0001). Conclusions: Doses at least as low as 69 Gy prescribed to the tumor apex achieve rates of local control, distant metastasis–free survival, and overall survival that are similar to radiation doses of 85 Gy to the tumor apex, but with improved visual outcomes.« less
DC-STAMP Is an Osteoclast Fusogen Engaged in Periodontal Bone Resorption
Wisitrasameewong, W.; Kajiya, M.; Movila, A.; Rittling, S.; Ishii, T.; Suzuki, M.; Matsuda, S.; Mazda, Y.; Torruella, M.R.; Azuma, M.M.; Egashira, K.; Freire, M.O.; Sasaki, H.; Wang, C.Y.; Han, X.; Taubman, M.A.; Kawai, T.
2017-01-01
Dendritic cell-specific transmembrane protein (DC-STAMP) plays a key role in the induction of osteoclast (OC) cell fusion, as well as DC-mediated immune regulation. While DC-STAMP gene expression is upregulated in the gingival tissue with periodontitis, its pathophysiological roles in periodontitis remain unclear. To evaluate the effects of DC-STAMP in periodontitis, anti-DC-STAMP–monoclonal antibody (mAb) was tested in a mouse model of ligature-induced periodontitis (n = 6–7/group) where Pasteurella pneumotropica (Pp)-reactive immune response activated T cells to produce receptor activator of nuclear factor kappa-B ligand (RANKL), which, in turn, promotes the periodontal bone loss via upregulation of osteoclastogenesis. DC-STAMP was expressed on the cell surface of mature multinuclear OCs, as well as immature mononuclear OCs, in primary cultures of RANKL-stimulated bone marrow cells. Anti-DC-STAMP-mAb suppressed the emergence of large, but not small, multinuclear OCs, suggesting that DC-STAMP is engaged in the late stage of cell fusion. Anti-DC-STAMP-mAb also inhibited pit formation caused by RANKL-stimulated bone marrow cells. Attachment of ligature to a second maxillary molar induced DC-STAMP messenger RNA and protein, along with elevated tartrate-resistant acid phosphatase–positive (TRAP+) OCs and alveolar bone loss. As we expected, systemic administration of anti-DC-STAMP-mAb downregulated the ligature-induced alveolar bone loss. Importantly, local injection of anti-DC-STAMP-mAb also suppressed alveolar bone loss and reduced the total number of multinucleated TRAP+ cells in mice that received ligature attachment. Attachment of ligature induced significantly elevated tumor necrosis factor–α, interleukin-1β, and RANKL in the gingival tissue compared with the control site without ligature (P < 0.05), which was unaffected by local injection with either anti-DC-STAMP-mAb or control-mAb. Neither in vivo anti-Pp IgG antibody nor in vitro anti-Pp T-cell response and resultant production of RANKL was affected by anti-DC-STAMP-mAb. This study illustrated the roles of DC-STAMP in promoting local OC cell fusion without affecting adaptive immune responses to oral bacteria. Therefore, it is plausible that a novel therapeutic regimen targeting DC-STAMP could suppress periodontal bone loss. PMID:28199142
Fischer, Peter E; Nunn, Andrew M; Wormer, Blair A; Christmas, A Britton; Gibeault, Lindsay A; Green, John M; Sing, Ronald F
2013-12-01
Management of destructive colon injuries during damage control (DC) laparotomy is debated. The authors reviewed a single institution's experience with destructive colon injuries to identify risk factors for anastomotic failure after colon reconstruction. The authors identified all trauma patients sustaining destructive colon injuries between 2002 and 2011 from their medical center's trauma registry. Anastomotic leak was defined as suture or staple line disruption or enteral fistula formation. Of 171 identified patients, 68 had DC procedures, 41 (60%) had subsequent anastomoses performed during the same hospitalization, and 27 (40%) were diverted. The colon anastomotic leak rate in patients who underwent DC laparotomy was higher than in patients who were reconstructed at the primary operation in a non-DC setting (17% vs 6%, P = .09). The use of vasopressors after the initial DC operation more than quadrupled the leak rate to 50% (P = .02). Colonic anastomotic disruptions yield deadly consequences, and diversion rather than anastomosis should be used in patients who require vasopressor support after the initial DC procedure. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1984-01-01
Kollmorgen Corporation's Mermaid II two person submersible is propeller-driven by a system of five DC brushless motors with new electronic controllers that originated in work performed in a NASA/DOE project managed by Lewis Research Center. A key feature of the system is electric commutation rather than mechanical commutation for converting AC current to DC.
22 CFR 128.5 - Answer and demand for oral hearing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of State for Defense Trade Controls, SA-1, Room 1200, Department of State, Washington, DC 20522-0112... for Defense Trade Controls, SA-1, Room 1200, Department of State, Washington, DC 20037. [58 FR 39320... Section 128.5 Foreign Relations DEPARTMENT OF STATE INTERNATIONAL TRAFFIC IN ARMS REGULATIONS...
77 FR 69556 - Airworthiness Directives; Eurocopter Deutschland Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-20
..., 2011. (h) Subject Joint Aircraft Service Component (JASC) Code: 2436: DC Generator Control Unit. Issued... Deutschland GmbH (ECD) Model MBB-BK117 C-2 helicopters with certain Generator Control Units (GCU) installed... Ground Floor, Room W12- 140, 1200 New Jersey Avenue SE., Washington, DC 20590. FOR FURTHER INFORMATION...
77 FR 30230 - Airworthiness Directives; Eurocopter Deutschland Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-22
... September 30, 2011. (g) Subject Joint Aircraft Service Component (JASC) Code: 2436: DC Generator Control... Deutschland GmbH Model MBB-BK117 C-2 helicopters with certain Generator Control Units (GCU) installed. This..., West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590-0001. Hand...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodges, Joseph C.; Das, Prajnan, E-mail: PrajDas@mdanderson.or; Eng, Cathy
2009-11-01
Purpose: To determine the rates of toxicity, locoregional control, distant control, and survival in anal cancer patients with para-aortic nodal involvement, treated with intensity-modulated radiotherapy (IMRT) and concurrent chemotherapy at a single institution. Methods and Materials: Between 2001 and 2007, 6 patients with squamous cell anal cancer and para-aortic nodal involvement were treated with IMRT and concurrent infusional 5-fluorouracil and cisplatin. The primary tumor was treated with a median dose of 57.5 Gy (range, 54-60 Gy), involved para-aortic, pelvic, and inguinal lymph nodes were treated with a median dose of 55 Gy (range, 50.5-55 Gy), and noninvolved nodal regions weremore » treated with a median dose of 45 Gy (range, 43.5-45 Gy). Results: After a median follow-up of 25 months, none of the patients had a recurrence at the primary tumor, pelvic/inguinal nodes, or para-aortic nodes, whereas 2 patients developed distant metastases to the liver. Four of the 6 patients are alive. The 3-year actuarial locoregional control, distant control, and overall survival rates were 100%, 56%, and 63%, respectively. Four of the 6 patients developed Grade 3 acute gastrointestinal toxicity during chemoradiation. Conclusions: Intensity-modulated radiotherapy and concurrent chemotherapy could potentially serve as definitive therapy in anal cancer patients with para-aortic nodal involvement. Adjuvant chemotherapy may be indicated in these patients, as demonstrated by the distant failure rates. These patients need to be followed carefully because of the potential for treatment-related toxicities.« less
Dual Active Bridge based DC Transformer LabVIEW FPGA Control Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
In the area of power electronics control, Field Programmable Gate Arrays (FPGAs) have the capability to outperform their Digital Signal Processor (DSP) counterparts due to the FPGA’s ability to implement true parallel processing and therefore facilitate higher switching frequencies, higher control bandwidth, and/or enhanced functionality. National Instruments (NI) has developed two platforms, Compact RIO (cRIO) and Single Board RIO (sbRIO), which combine a real-time processor with an FPGA. The FPGA can be programmed with a subset of the well-known LabVIEW graphical programming language. The candidate software implements complete control algorithms in LabVIEW FPGA for a DC Transformer (DCX) based onmore » a dual active bridge (DAB). A DCX is an isolated bi-directional DC-DC converter designed to operate at unity conversion ratio, M, defined by where Vin is the primary-side DC bus voltage, Vout is the secondary-side DC bus voltage, and n is the turns ratio of the embedded high frequency transformer (HFX). The DCX based on a DAB incorporates two H-bridges, a resonant inductor, and an HFX to provide this functionality. The candidate software employs phase-shift modulation of the two H-bridges and a feedback loop to regulate the conversion ratio at unity. The software also includes alarm-handling capabilities as well as debugging and tuning tools. The software fits on the Xilinx Virtex V LX110 FPGA embedded in the NI cRIO-9118 FPGA chassis, and with a 40 MHz base clock, supports a modulation update rate of 40 MHz, and user-settable switching frequencies and synchronized control loop update rates of tens of kHz.« less
Test Results of Selected Commercial DC/DC Converters under Cryogenic Temperatures - A Digest
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad
2010-01-01
DC/DC converters are widely used in space power systems in the areas of power management and distribution, signal conditioning, and motor control. Design of DC/DC converters to survive cryogenic temperatures will improve the power system performance, simplify design, and reduce development and launch costs. In this work, the performance of nine COTS modular, low-tomedium power DC/DC converters was investigated under cryogenic temperatures. The converters were evaluated in terms of their output regulation, efficiency, and input and output currents. At a given temperature, these properties were obtained at various input voltages and at different load levels. A summary on the performance of the tested converters was given. More comprehensive testing and in-depth analysis of performance under long-term exposure to extreme temperatures are deemed necessary to establish the suitability of these and other devices for use in the harsh environment of space exploration missions.
Stampalija, T; Casati, D; Monasta, L; Sassi, R; Rivolta, M W; Muggiasca, M L; Bauer, A; Ferrazzi, E
2016-11-01
Phase rectified signal averaging (PRSA) is a new method of fetal heart rate variability (fHRV) analysis that quantifies the average acceleration (AC) and deceleration capacity (DC) of the heart. The aim of this study was to evaluate AC and DC of fHR [recorded by trans-abdominal fetal electrocardiogram (ta-fECG)] in relation to Doppler velocimetry characteristics of intrauterine growth restriction (IUGR). Prospective case-control study. Single third referral centre. IUGR (n = 66) between 25 and 40 gestational weeks and uncomplicated pregnancies (n = 79). In IUGR the nearest ta-fECG monitoring to delivery was used for PRSA analysis and Doppler velocimetry parameters obtained within 48 hours. AC and DC were computed at s = T = 9. The relation was evaluated between either AC or DC and Doppler velocimetry parameters adjusting for gestational age at monitoring, as well as the association between either AC or DC and IUGR with or without brain sparing. In IUGRs there was a significant association between either AC and DC and middle cerebral artery pulsatility index (PI; P = 0.01; P = 0.005), but the same was not true for uterine or umbilical artery PI (P > 0.05). Both IUGR fetuses with and without brain sparing had lower AC and DC than controls, but this association was stronger for IUGRs with brain sparing. Our study observed for the first time that AC and DC at PRSA analysis are associated with middle cerebral artery PI, but not with uterine or umbilical artery PI, and that there is a significant decrease of AC and DC in association with brain sparing in IUGR fetuses from 25 weeks of gestation to term. Brain sparing in IUGR fetuses is associated with decreased acceleration and deceleration capacities of the heart. © 2015 Royal College of Obstetricians and Gynaecologists.
Maruyama, Hiroshi; Hirayama, Kouichi; Nagai, Miho; Ebihara, Itaru; Shimohata, Homare; Kobayashi, Masaki
2016-10-01
Type 17 T-helper (Th17) cells have been suggested to be involved in the pathogenesis of antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV). Th17 cell proliferation is promoted by tumor necrosis factor (TNF)-like ligand 1A (TL1A), which binds to death receptor 3 (DR3) expressed on Th17 cells. Decoy receptor 3 (DcR3) is known to block the TL1A-DR3 pathway by binding TL1A. To evaluate the Th17-TL1A systems as disease activity markers in AAV, we investigated the serum levels of TL1A and DcR3 in AAV patients. Serum IL-17, IL-23, TL1A, and DcR3 were measured by ELISA in 24 AAV patients with microscopic polyangiitis before the initial treatment, 24 AAV patients during remission, and 20 control subjects. There were no significant differences in serum IL-17, IL-23, and TL1A levels among the active-vasculitis patients, inactive-vasculitis patients, and controls. The mean serum DcR3 level was significantly higher in the active-vasculitis patients than in the inactive-vasculitis patients and controls (P < 0.0001, respectively). There were significant positive correlations between the serum DcR3 levels and Birmingham Vasculitis Activity Score (BVAS), myeloperoxidase (MPO)-ANCA titers, white blood cell counts, serum creatinine levels, and serum C-reactive protein levels. In a multiple regression analysis, there was a significant positive correlation between the serum DcR3 level and BVAS (β = 0.650, P = 0.0462). The mean BVAS level was significantly higher in the active-vasculitis patients with high serum DcR3 levels than in those with the low serum DcR3 levels (P = 0.0202). The serum level of DcR3 may be a useful marker for disease activity in AAV.
Zheng, W; Tang, L R; Correll, C U; Ungvari, G S; Chiu, H F K; Xiang, Y Q; Xiang, Y T
2015-09-01
Distant visual impairment in the severely mentally ill is under-researched. This study aimed to assess the frequency and correlates of distant visual impairment in a cohort of Chinese psychiatric patients, including its effect on their quality of life. Adult psychiatric inpatients with schizophrenia, bipolar disorder, and major depressive disorder consecutively admitted to a psychiatric hospital in Beijing, China underwent assessments of psychopathology (Brief Psychiatric Rating Scale, 16-item Quick Inventory of Depressive Symptomatology [Self-Report]), quality of life (12-item Short-Form Medical Outcomes Study [SF-12], 25-item National Eye Institute Visual Function Questionnaire [NEI-VFQ25]), adverse effects (Udvalg for Kliniske Undersøgelser Side Effect Rating Scale), and presenting (as opposed to uncorrected) distant visual acuity (Logarithm of the Minimum Angle of Resolution [LogMAR] chart with patients wearing spectacles, if they owned them). Distant visual impairment was defined as binocular distant visual acuity of a LogMAR score of ≥ 0.5 (< 6/18 Snellen acuity). Among 356 patients who met the study criteria, the frequency of distant visual impairment was 12.6% (15.2% with schizophrenia, 11.9% with bipolar disorder, 8.8% with major depressive disorder). In multiple logistic regression analysis, distant visual impairment was significantly associated with ocular disease only (p = 0.002, odds ratio = 3.2, 95% confidence interval = 1.5-6.7). Controlling for the confounding effect of ocular disease, patients with distant visual impairment had a lower quality of life in the general vision domain of the NEI-VFQ25 (F[2, 353] = 9.5, p = 0.002) compared with those without. No differences in the physical and mental domains of the SF-12 and in other domains of the NEI-VFQ25 were noted in these 2 groups. One-eighth of middle-aged severely mentally ill patients had distant visual impairment. Considering the impact of distant visual impairment on daily functioning, severely mentally ill patients need to be screened for impaired eyesight as part of their comprehensive health assessment.
Power Converters Maximize Outputs Of Solar Cell Strings
NASA Technical Reports Server (NTRS)
Frederick, Martin E.; Jermakian, Joel B.
1993-01-01
Microprocessor-controlled dc-to-dc power converters devised to maximize power transferred from solar photovoltaic strings to storage batteries and other electrical loads. Converters help in utilizing large solar photovoltaic arrays most effectively with respect to cost, size, and weight. Main points of invention are: single controller used to control and optimize any number of "dumb" tracker units and strings independently; power maximized out of converters; and controller in system is microprocessor.
ELECTRONIC PHASE CONTROL CIRCUIT
Salisbury, J.D.; Klein, W.W.; Hansen, C.F.
1959-04-21
An electronic circuit is described for controlling the phase of radio frequency energy applied to a multicavity linear accelerator. In one application of the circuit two cavities are excited from a single radio frequency source, with one cavity directly coupled to the source and the other cavity coupled through a delay line of special construction. A phase detector provides a bipolar d-c output signal proportional to the difference in phase between the voltage in the two cavities. This d-c signal controls a bias supply which provides a d-c output for varying the capacitnce of voltage sensitive capacitors in the delay line. The over-all operation of the circuit is completely electronic, overcoming the time response limitations of the electromechanical control systems, and the relative phase relationship of the radio frequency voltages in the two caviiies is continuously controlled to effect particle acceleration.
vanderVaart, Sondra; Berger, Howard; Tam, Carolyn; Goh, Y Ingrid; Gijsen, Violette M G J; de Wildt, Saskia N; Taddio, Anna
2011-01-01
Introduction Approximately 25% of all babies in North America are delivered via Caesarean section (C-section). Though a common surgical procedure, C-section recovery can be painful. Opioids, specifically codeine, are commonly used to ease pain; however, its active metabolite, morphine, passes into breast milk, and may produce unwanted side effects in neonates; therefore, alternatives to opioids are being sought. Reiki is an ancient Japanese form of healing where practitioners transfer healing energy through light touch and positive healing intention. Although 1.2 million Americans use reiki to reduce pain or depression, there is a lack of strong evidence supporting its effectiveness. A recent systematic review showed existing studies to be of poor methodological quality, with the common limitation of lack of blinding. To overcome this issue, the authors used distant reiki to assess its effectiveness in reducing pain following an elective C-section. Methods In this randomised, double-blinded study, women who underwent an elective C-section were allocated to either usual care (control, n=40) or three distant reiki sessions in addition to usual care (n=40). Pain was assessed using a visual analogue scale (VAS). The primary endpoint was the Area Under the VAS-Time Curve (AUC) for days 1–3. Secondary measures included: the proportion of women who required opioid medications and dose consumed, rate of healing and vital signs. Results AUC for pain was not significantly different in the distant reiki and control groups (mean±SD; 212.1±104.7 vs 223.1±117.8; p=0.96). There were no significant differences in opioid consumption or rate of healing; however, the distant reiki group had a significantly lower heart rate (74.3±8.1 bpm vs 79.8±7.9 bpm, p=0.003) and blood pressure (106.4±9.7 mm Hg vs 111.9±11.0 mm Hg, p=0.02) post surgery. Conclusion Distant reiki had no significant effect on pain following an elective C-section. Clinical Trial Registration Number ISRCTN79265996. PMID:22021729
Pulsed-DC DBD Plasma Actuators
NASA Astrophysics Data System (ADS)
Duong, Alan; Corke, Thomas; Thomas, Flint
2017-11-01
A power system for dielectric barrier discharge (DBD) plasma actuators that utilizes a pulsed-DC waveform is presented. The plasma actuator arrangement is identical to most typical AC-DBD designs with staggered electrodes that are separated by a dielectric insulator. A key difference is that the pulsed-DC actuator utilizes a DC voltage source to drive the actuator instead of an AC voltage input. The DC source is supplied to both electrodes. The exposed electrode remains constant in time while the encapsulated electrode is periodically grounded for short instances then is allowed to rise to the source DC level. Further investigation of the pulsed-DC plasma actuator was conducted. Time-resolved velocity measurements were done to characterize the induced velocity field generated by the pulsed-DC plasma actuator. A model of the pulsed-DC plasma actuator is developed in LTspice for further study. The work presented are intended in developing a model to be used in CFD flow control simulations. NASA SBIR NNX14CC12C.
Mulligan, Jennifer K; O'Connell, Brendan P; Pasquini, Whitney; Mulligan, Ryan M; Smith, Sarah; Soler, Zachary M; Atkinson, Carl; Schlosser, Rodney J
2017-08-01
In these studies we examined the impact of environmental tobacco smoke (ETS) and active smoking on sinonasal dendritic cell (DC) subsets in controls or patients with chronic rhinosinusitis with nasal polyps (CRSwNP). In subsequent in-vitro investigations, we examined the influence of cigarette smoke extract (CSE) on human sinonasal epithelial cells' (HSNECs) ability to regulate DC functions. Sinonasal tissue, blood, and hair were collected from patients undergoing sinus surgery. Smoking status and ETS exposure were determined by hair nicotine. DC subsets were examined by flow cytometric analysis. Monocyte-derived dendritic cells (moDCs) were treated with conditioned medium from non-smoked-exposed HSNECs (NS-HSNECs) or cigarette-smoke-extract-exposed HSNECs (CSE-HSNECs) to assess the impact of CSE exposure on HSNEC regulation of moDC functions. Control subjects who were active smokers displayed increased sinonasal moDC and myeloid dendritic 1 (mDC1) cells and reduced mDC2 cells, whereas, in CRSwNP patients, only moDC and mDC2 cells were altered. ETS was found to increase only moDCs in the CRSwNP patients. In vitro, CSE stimulated HSNEC secretion of the moDC regulatory products chemokine (C-C motif) ligand 20, prostaglandin E 2 , and granulocyte-macrophage colony-stimulating factor. CSE exposure also promoted HSNECs to stimulate monocyte and moDC migration. moDCs treated with CSE-HSNEC media stimulated an increase in antigen uptake and expression of CD80 and CD86. Last, CSE-HSNEC-treated moDCs secreted increased levels of interleukin-10, interferon-γ, and thymic stromal lymphopoietin. Active smoking, and to a lesser degree ETS, alters the sinonasal composition of DCs. A potential mechanism to account for this is that cigarette smoke stimulates HSNECs to induce moDC migration, maturation, and activation. © 2017 ARS-AAOA, LLC.
Kong, Bingxin; Liu, Siqi; Yin, Jie; Li, Shengru; Zhu, Zuqing
2018-05-28
Nowadays, it is common for service providers (SPs) to leverage hybrid clouds to improve the quality-of-service (QoS) of their Big Data applications. However, for achieving guaranteed latency and/or bandwidth in its hybrid cloud, an SP might desire to have a virtual datacenter (vDC) network, in which it can manage and manipulate the network connections freely. To address this requirement, we design and implement a network slicing and orchestration (NSO) system that can create and expand vDCs across optical/packet domains on-demand. Considering Hadoop MapReduce (M/R) as the use-case, we describe the proposed architectures of the system's data, control and management planes, and present the operation procedures for creating, expanding, monitoring and managing a vDC for M/R optimization. The proposed NSO system is then realized in a small-scale network testbed that includes four optical/packet domains, and we conduct experiments in it to demonstrate the whole operations of the data, control and management planes. Our experimental results verify that application-driven on-demand vDC expansion across optical/packet domains can be achieved for M/R optimization, and after being provisioned with a vDC, the SP using the NSO system can fully control the vDC network and further optimize the M/R jobs in it with network orchestration.
Driving many distant atoms into high-fidelity steady state entanglement via Lyapunov control.
Li, Chuang; Song, Jie; Xia, Yan; Ding, Weiqiang
2018-01-22
Based on Lyapunov control theory in closed and open systems, we propose a scheme to generate W state of many distant atoms in the cavity-fiber-cavity system. In the closed system, the W state is generated successfully even when the coupling strength between the cavity and fiber is extremely weak. In the presence of atomic spontaneous emission or cavity and fiber decay, the photon-measurement and quantum feedback approaches are proposed to improve the fidelity, which enable efficient generation of high-fidelity W state in the case of large dissipation. Furthermore, the time-optimal Lyapunov control is investigated to shorten the evolution time and improve the fidelity in open systems.
NASA Astrophysics Data System (ADS)
Kumar, Naveen; Dubey, Ashish; Bahrami, Behzad; Venkatesan, S.; Qiao, Qiquan; Kumar, Mukesh
2018-04-01
In this work, the energy and flux of high energetic ions were controlled by RF superimposed DC sputtering process to increase the grain size and suppress grain boundary potential with minimum residual stress in Al doped ZnO (AZO) thin film. AZO thin films were deposited at different RF/(RF + DC) ratios by keeping total power same and were investigated for their electrical, optical, structural and nanoscale grain boundaries potential. All AZO thin film showed high crystallinity and orientation along (002) with peak shift as RF/(RF + DC) ratio increased from 0.0, pure DC, to 1.0, pure RF. This peak shift was correlated with high residual stress in as-grown thin film. AZO thin film grown at mixed RF/(RF + DC) of 0.75 showed high electron mobility, low residual stress and large crystallite size in comparison to other AZO thin films. The nanoscale grain boundary potential was mapped using Kelvin Probe Force Microscopy in all AZO thin film and it was observed that carrier mobility is controlled not only by grains size but also by grain boundary potential. The XPS analysis confirms the variation in oxygen vacancies and zinc interstitials which explain the origin of low grain boundaries potential and high carrier mobility in AZO thin film deposited at 0.75 RF/(RF + DC) ratio. This study proposes a new way to control the grain size and grain boundary potential to further tune the optoelectronic-mechanical properties of AZO thin films for next generation flexible and optoelectronic devices.
78 FR 61177 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-03
... Distribution Centre (MDC) rack panel is subject to flexing, due to the weight of the two DC Generator Control... Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590. Hand Delivery: U.S. Department of...., Washington, DC, between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. For service...
14 CFR 93.341 - Aircraft operations in the DC FRZ.
Code of Federal Regulations, 2010 CFR
2010-01-01
...-assigned discrete transponder code. The pilot must monitor VHF frequency 121.5 or UHF frequency 243.0. (d... authorization must file and activate an IFR or a DC FRZ or a DC SFRA flight plan and transmit a discrete transponder code assigned by an Air Traffic Control facility. Aircraft must transmit the discrete transponder...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-15
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-698 (Enforcement Proceeding)] Certain DC... delegated by the President, has 60 days to approve or disapprove the Commission's action. See 19 U.S.C. 1337...). Submissions should refer to the investigation number (``Inv. No. 337-TA-698'') in a prominent place on the...
NASA Technical Reports Server (NTRS)
Ohri, A. K.; Owen, H. A.; Wilson, T. G.; Rodriguez, G. E.
1974-01-01
The simulation of converter-controller combinations by means of a flexible digital computer program which produces output to a graphic display is discussed. The procedure is an alternative to mathematical analysis of converter systems. The types of computer programming involved in the simulation are described. Schematic diagrams, state equations, and output equations are displayed for four basic forms of inductor-energy-storage dc to dc converters. Mathematical models are developed to show the relationship of the parameters.
IFN-α regulates Blimp-1 expression via miR-23a and miR-125b in both monocytes-derived DC and pDC.
Parlato, Stefania; Bruni, Roberto; Fragapane, Paola; Salerno, Debora; Marcantonio, Cinzia; Borghi, Paola; Tataseo, Paola; Ciccaglione, Anna Rita; Presutti, Carlo; Romagnoli, Giulia; Bozzoni, Irene; Belardelli, Filippo; Gabriele, Lucia
2013-01-01
Type I interferon (IFN-I) have emerged as crucial mediators of cellular signals controlling DC differentiation and function. Human DC differentiated from monocytes in the presence of IFN-α (IFN-α DC) show a partially mature phenotype and a special capability of stimulating CD4+ T cell and cross-priming CD8+ T cells. Likewise, plasmacytoid DC (pDC) are blood DC highly specialized in the production of IFN-α in response to viruses and other danger signals, whose functional features may be shaped by IFN-I. Here, we investigated the molecular mechanisms stimulated by IFN-α in driving human monocyte-derived DC differentiation and performed parallel studies on peripheral unstimulated and IFN-α-treated pDC. A specific miRNA signature was induced in IFN-α DC and selected miRNAs, among which miR-23a and miR-125b, proved to be negatively associated with up-modulation of Blimp-1 occurring during IFN-α-driven DC differentiation. Of note, monocyte-derived IFN-α DC and in vitro IFN-α-treated pDC shared a restricted pattern of miRNAs regulating Blimp-1 expression as well as some similar phenotypic, molecular and functional hallmarks, supporting the existence of a potential relationship between these DC populations. On the whole, these data uncover a new role of Blimp-1 in human DC differentiation driven by IFN-α and identify Blimp-1 as an IFN-α-mediated key regulator potentially accounting for shared functional features between IFN-α DC and pDC.
IFN-α Regulates Blimp-1 Expression via miR-23a and miR-125b in Both Monocytes-Derived DC and pDC
Parlato, Stefania; Salerno, Debora; Marcantonio, Cinzia; Borghi, Paola; Tataseo, Paola; Ciccaglione, Anna Rita; Presutti, Carlo; Romagnoli, Giulia; Bozzoni, Irene; Belardelli, Filippo; Gabriele, Lucia
2013-01-01
Type I interferon (IFN-I) have emerged as crucial mediators of cellular signals controlling DC differentiation and function. Human DC differentiated from monocytes in the presence of IFN-α (IFN-α DC) show a partially mature phenotype and a special capability of stimulating CD4+ T cell and cross-priming CD8+ T cells. Likewise, plasmacytoid DC (pDC) are blood DC highly specialized in the production of IFN-α in response to viruses and other danger signals, whose functional features may be shaped by IFN-I. Here, we investigated the molecular mechanisms stimulated by IFN-α in driving human monocyte-derived DC differentiation and performed parallel studies on peripheral unstimulated and IFN-α-treated pDC. A specific miRNA signature was induced in IFN-α DC and selected miRNAs, among which miR-23a and miR-125b, proved to be negatively associated with up-modulation of Blimp-1 occurring during IFN-α-driven DC differentiation. Of note, monocyte-derived IFN-α DC and in vitro IFN-α-treated pDC shared a restricted pattern of miRNAs regulating Blimp-1 expression as well as some similar phenotypic, molecular and functional hallmarks, supporting the existence of a potential relationship between these DC populations. On the whole, these data uncover a new role of Blimp-1 in human DC differentiation driven by IFN-α and identify Blimp-1 as an IFN-α-mediated key regulator potentially accounting for shared functional features between IFN-α DC and pDC. PMID:23977359
Control of Grid Connected Photovoltaic System Using Three-Level T-Type Inverter
NASA Astrophysics Data System (ADS)
Zorig, Abdelmalik; Belkeiri, Mohammed; Barkat, Said; Rabhi, Abdelhamid
2016-08-01
Three-level T-Type inverter (3LT2I) topology has numerous advantageous compared to three-level neutral-point-clamped (NPC) inverter. The main benefits of 3LT2I inverter are the efficiency, inverter cost, switching losses, and the quality of output voltage waveforms. In this paper, a photovoltaic distributed generation system based on dual-stage topology of DC-DC boost converter and 3LT2I is introduced. To that end, a decoupling control strategy of 3LT2I is proposed to control the current injected into the grid, reactive power compensation, and DC-link voltage. The resulting system is able to extract the maximum power from photovoltaic generator, to achieve sinusoidal grid currents, and to ensure reactive power compensation. The voltage-balancing control of two split DC capacitors of the 3LT2I is achieved using three-level space vector modulation with balancing strategy based on the effective use of the redundant switching states of the inverter voltage vectors. The proposed system performance is investigated at different operating conditions.
Sekar, Divya; Brüne, Bernhard; Weigert, Andreas
2010-08-01
The division of labor between DC subsets is evolutionarily well-defined. mDC are efficient in antigen presentation, whereas pDC act as rheostats of the immune system. They activate NK cells, cause bystander activation of mDC, and interact with T cells to induce tolerance. This ambiguity positions pDC at the center of inflammatory diseases, such as cancer, arthritis, and autoimmune diseases. The ability to generate human mDC ex vivo made it possible to engineer them to suit therapy needs. Unfortunately, a similar, easily accessible system to generate human pDC is not available. We describe a method to generate human pDC equivalents ex vivo, termed mo-pDC from peripheral blood monocytes using Flt3-L. mo-pDC showed a characteristic pDC profile, such as high CD123 and BDCA4, but low CD86 and TLR4 surface expression and a low capacity to induce autologous lymphocyte proliferation and to phagocytose apoptotic debris in comparison with mDC. Interestingly, mo-pDC up-regulated the pDC lineage-determining transcription factor E2-2 as well as expression of BDCA2, which is under the transcriptional control of E2-2 but not its inhibitor ID2, during differentiation. mo-pDC produced high levels of IFN-alpha when pretreated overnight with TNF-alpha. Under hypoxia, E2-2 was down-regulated, and ID2 was induced in mo-pDC, whereas surface expression of MHCI, CD86, and BDCA2 was decreased. Furthermore, mo-pDC produced high levels of inflammatory cytokines when differentiated under hypoxia compared with normoxia. Hence, mo-pDC can be used to study differentiation and functions of human pDC under microenvironmental stimuli.
Cryogenic Evaluation of an Advanced DC/DC Converter Module for Deep Space Applications
NASA Technical Reports Server (NTRS)
Elbuluk, Malik E.; Hammoud, Ahmad; Gerber, Scott S.; Patterson, Richard
2003-01-01
DC/DC converters are widely used in power management, conditioning, and control of space power systems. Deep space applications require electronics that withstand cryogenic temperature and meet a stringent radiation tolerance. In this work, the performance of an advanced, radiation-hardened (rad-hard) commercial DC/DC converter module was investigated at cryogenic temperatures. The converter was investigated in terms of its steady state and dynamic operations. The output voltage regulation, efficiency, terminal current ripple characteristics, and output voltage response to load changes were determined in the temperature range of 20 to -140 C. These parameters were obtained at various load levels and at different input voltages. The experimental procedures along with the results obtained on the investigated converter are presented and discussed.
Su, Gui-Jia
2003-06-10
A multilevel DC link inverter and method for improving torque response and current regulation in permanent magnet motors and switched reluctance motors having a low inductance includes a plurality of voltage controlled cells connected in series for applying a resulting dc voltage comprised of one or more incremental dc voltages. The cells are provided with switches for increasing the resulting applied dc voltage as speed and back EMF increase, while limiting the voltage that is applied to the commutation switches to perform PWM or dc voltage stepping functions, so as to limit current ripple in the stator windings below an acceptable level, typically 5%. Several embodiments are disclosed including inverters using IGBT's, inverters using thyristors. All of the inverters are operable in both motoring and regenerating modes.
Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor
NASA Astrophysics Data System (ADS)
Afiqah Zainal, Nurul; Sooi Tat, Chan; Ajisman
2016-02-01
Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's ou tput is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor.
A neuro-inspired spike-based PID motor controller for multi-motor robots with low cost FPGAs.
Jimenez-Fernandez, Angel; Jimenez-Moreno, Gabriel; Linares-Barranco, Alejandro; Dominguez-Morales, Manuel J; Paz-Vicente, Rafael; Civit-Balcells, Anton
2012-01-01
In this paper we present a neuro-inspired spike-based close-loop controller written in VHDL and implemented for FPGAs. This controller has been focused on controlling a DC motor speed, but only using spikes for information representation, processing and DC motor driving. It could be applied to other motors with proper driver adaptation. This controller architecture represents one of the latest layers in a Spiking Neural Network (SNN), which implements a bridge between robotics actuators and spike-based processing layers and sensors. The presented control system fuses actuation and sensors information as spikes streams, processing these spikes in hard real-time, implementing a massively parallel information processing system, through specialized spike-based circuits. This spike-based close-loop controller has been implemented into an AER platform, designed in our labs, that allows direct control of DC motors: the AER-Robot. Experimental results evidence the viability of the implementation of spike-based controllers, and hardware synthesis denotes low hardware requirements that allow replicating this controller in a high number of parallel controllers working together to allow a real-time robot control.
A Neuro-Inspired Spike-Based PID Motor Controller for Multi-Motor Robots with Low Cost FPGAs
Jimenez-Fernandez, Angel; Jimenez-Moreno, Gabriel; Linares-Barranco, Alejandro; Dominguez-Morales, Manuel J.; Paz-Vicente, Rafael; Civit-Balcells, Anton
2012-01-01
In this paper we present a neuro-inspired spike-based close-loop controller written in VHDL and implemented for FPGAs. This controller has been focused on controlling a DC motor speed, but only using spikes for information representation, processing and DC motor driving. It could be applied to other motors with proper driver adaptation. This controller architecture represents one of the latest layers in a Spiking Neural Network (SNN), which implements a bridge between robotics actuators and spike-based processing layers and sensors. The presented control system fuses actuation and sensors information as spikes streams, processing these spikes in hard real-time, implementing a massively parallel information processing system, through specialized spike-based circuits. This spike-based close-loop controller has been implemented into an AER platform, designed in our labs, that allows direct control of DC motors: the AER-Robot. Experimental results evidence the viability of the implementation of spike-based controllers, and hardware synthesis denotes low hardware requirements that allow replicating this controller in a high number of parallel controllers working together to allow a real-time robot control. PMID:22666004
DC Potentials Applied to an End-cap Electrode of a 3-D Ion Trap for Enhanced MSn Functionality
Prentice, Boone M.; Xu, Wei; Ouyang, Zheng; McLuckey, Scott A.
2010-01-01
The effects of the application of various DC magnitudes and polarities to an end-cap of a 3-D quadrupole ion trap throughout a mass spectrometry experiment were investigated. Application of a monopolar DC field was achieved by applying a DC potential to the exit end-cap electrode, while maintaining the entrance end-cap electrode at ground potential. Control over the monopolar DC magnitude and polarity during time periods associated with ion accumulation, mass analysis, ion isolation, ion/ion reaction, and ion activation can have various desirable effects. Included amongst these are increased ion capture efficiency, increased ion ejection efficiency during mass analysis, effective isolation of ions using lower AC resonance ejection amplitudes, improved temporal control of the overlap of oppositely charged ion populations, and the performance of “broad-band” collision induced dissociation (CID). These results suggest general means to improve the performance of the 3-D ion trap in a variety of mass spectrometry and tandem mass spectrometry experiments. PMID:21927573
Chen, Qiang; Cui, Xiao-Xu; Liang, Pei-Fen; Dou, Jin-Xia; Liu, Zi-Yan; Sun, Wen-Wen
2016-01-01
Objective: To compare the effects and safety of immunotherapy using different methods to load DC-CIK cells for MDA-MB-231 breast cancer stem cells. Methods: A breast cancer model was established in BALB/c nude mice using breast cancer stem cells. All mice were randomly divided into six groups, and each group had three nude mice: the blank control group, the DC-CIK group (group D), the MDA-MB-231 CSC whole-cell lysate DC-CIK group (group L-D), the MDA-MB-231 CSC RNA DC-CIK group (group R-D), the THP DC-CIK group (group T-D) and group THP. Nude mice in groups D, L-D, R-D and T-D were injected with CSCs; 4 days later, the mice were inoculated with 1 × 106 DC-CIK cells via the tail vein. This injection was repeated 2 times a week for three weeks. The mice in groups THP and T-D were injected with a 5 mg/Kg dose of THP chemotherapeutic agents via the tail vein the day before DC-CIK injection, which was repeated one time a week for three weeks. Nude mice in the blank control group were injected with normal saline. The weights and sizes of the tumors were measured after the mice were euthanized. The expression of c-Myc, a key proto-oncogene associated with the Akt signaling pathway, was detected with RT-PCR. Results: The tumor growth rates in each group were as follows: group L-D < group R-D < group D < group T-D < blank control group < group THP. The nude mice in groups L-D, R-D and D were normal, active and had a healthy appetite. The mice in groups T-D and THP were lethargic, less active and showed loss of appetite, and their caudal vein was easy to stimulate. The mice in the blank control group were sacrificed during the third week or when their tumors developed ulceration. Compared with the blank control group, c-Myc gene expression was reduced in the tumors of the five experimental groups. Conclusion: The results showed that DC-CIK cells stimulated by different methods were highly effect against MDA-MB-231 breast cancer stem cells in nude mice in all groups, especially in group L-D. DC-CIK immunotherapy may provide a new strategy for the clinical treatment of breast cancer. PMID:27508015
Chen, Qiang; Cui, Xiao-Xu; Liang, Pei-Fen; Dou, Jin-Xia; Liu, Zi-Yan; Sun, Wen-Wen
2016-01-01
To compare the effects and safety of immunotherapy using different methods to load DC-CIK cells for MDA-MB-231 breast cancer stem cells. A breast cancer model was established in BALB/c nude mice using breast cancer stem cells. All mice were randomly divided into six groups, and each group had three nude mice: the blank control group, the DC-CIK group (group D), the MDA-MB-231 CSC whole-cell lysate DC-CIK group (group L-D), the MDA-MB-231 CSC RNA DC-CIK group (group R-D), the THP DC-CIK group (group T-D) and group THP. Nude mice in groups D, L-D, R-D and T-D were injected with CSCs; 4 days later, the mice were inoculated with 1 × 10(6) DC-CIK cells via the tail vein. This injection was repeated 2 times a week for three weeks. The mice in groups THP and T-D were injected with a 5 mg/Kg dose of THP chemotherapeutic agents via the tail vein the day before DC-CIK injection, which was repeated one time a week for three weeks. Nude mice in the blank control group were injected with normal saline. The weights and sizes of the tumors were measured after the mice were euthanized. The expression of c-Myc, a key proto-oncogene associated with the Akt signaling pathway, was detected with RT-PCR. The tumor growth rates in each group were as follows: group L-D < group R-D < group D < group T-D < blank control group < group THP. The nude mice in groups L-D, R-D and D were normal, active and had a healthy appetite. The mice in groups T-D and THP were lethargic, less active and showed loss of appetite, and their caudal vein was easy to stimulate. The mice in the blank control group were sacrificed during the third week or when their tumors developed ulceration. Compared with the blank control group, c-Myc gene expression was reduced in the tumors of the five experimental groups. The results showed that DC-CIK cells stimulated by different methods were highly effect against MDA-MB-231 breast cancer stem cells in nude mice in all groups, especially in group L-D. DC-CIK immunotherapy may provide a new strategy for the clinical treatment of breast cancer.
Ionospheric Irregularity Physics Modelling.
1982-02-09
NUMBERS Washington, DC 20375 62715H; 47-0889-0-2 II CONTROLLING OFFICE NAME AND ADDRESS 12 REPORT DATE Defense Nuclear Agency February 9, 1982 Washington... CONTROL TECHNICAL CENTER COMMANDER PE TAGON RM SF 685 FIELD COMMAND WASHINGTON, D.C. 20301 DEFENSE NUCLEAR AGENCY OICY ATTN C-650 KIRTLAND, AFR, NM...BUILDINICG KIRTLAND AFB, NM 87115 1400 WILSON BLVD. OICY ATTN DOCUMENT CONTROL ARLINGTON, 11A. 22209 OICY ATTN NUCLEAR MONITORING RESEARCH JOINT CHIEFS OF
Influence of Insulation Monitoring Devices on the Operation of DC Control Circuits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olszowiec, Piotr, E-mail: olpio@o2.pl
The insulation level of DC control circuits is an important safety-critical factor and, thus, should be subject to continuous and periodic monitoring. The methods used for monitoring the insulation in live circuits may, however, disturb the reliable operation of control relays. The risks of misoperation and failure to reset of relays posed by the operation of various insulation monitoring and fault location systems are evaluated.
Blood volume reduction counteracts fluid shifts in water immersion
NASA Technical Reports Server (NTRS)
Simanonok, Karl E.; Bernauer, Edmund
1993-01-01
Six healthy men were bled by 15 percent of their total blood volume (TBV) before 7 h of seated water immersion, to test the hypothesis that some of the major physiological responses to an expansion of central blood volume can be counteracted by prior reduction of TBV. Subjects were their own controls under two conditions: seated dry in air and seated immersed to the suprasternal notch in water. Immersion without prior reduction of TBV Wet Control (WC) caused a statistically significant 22-percent increase in cardiac output (CO), 368-percent increase in urine production, and 200-percent increase in sodium excretion relative to dry control (DC) sessions. When TBV was reduced before immersion, CO was the same as during DC sessions; however there were significant increases above DC in urine flow (+73 percent) and sodium excretion (+120 percent), although they were significantly reduced from WC values. Potassium excretion was similar during DC and WC sessions, but was significantly increased (+75 percent) when subjects were immersed after 15-percent reduction of TBV.
Zhou, Xiao-Na; Li, Guang-Ming; Xu, Ying-Chen; Zhao, Tuan-Jie; Wu, Ji-Xiang
2016-11-05
Decoy receptor 3 (DcR3) binds to Fas ligand (FasL) and inhibits FasL-induced apoptosis. The receptor is overexpressed in hepatocellular carcinoma (HCC), and it is associated with the growth and metastatic spread of tumors. DcR3 holds promises as a new target for the treatment of HCC, but little is known regarding the molecular mechanisms underlying the oncogenic properties of DcR3. The present work, therefore, examined the role of DcR3 in regulating the growth and invasive property of liver cancer cell HepG2. HepG2 cells were stably transfected with lentivirus-based short hairpin RNA vector targeting DcR3. After the knockdown of DcR3 was confirmed, cell proliferation, clone formation, ability of migrating across transwell membrane, and wound healing were assessed in vitro. Matrix metalloproteinase-9 (MMP 9) and vascular epithelial growth factor (VEGF)-C and D expressions of the DcR3 knockdown were also studied. Comparisons between multiple groups were done using one-way analysis of variance (ANOVA), while pairwise comparisons were performed using Student's t test. P< 0.05 was regarded statistically significant. DcR3 was overexpressed in HepG2 compared to other HCC cell lines and normal hepatocyte Lo-2. Stable knockdown of DcR3 slowed down the growth of HepG2 (P < 0.05) and reduced the number of clones formed by 50% compared to those without DcR3 knockdown (P < 0.05). The knockdown also reduced the migration of HepG2 across transwell matrix membrane by five folds compared to the control (P < 0.05) and suppressed the closure of scratch wound (P < 0.05). In addition, the messenger RNA levels of MMP 9, VEGF-C, and VEGF-D were significantly suppressed by DcR3 knockdown by 90% when compared with the mock control (P < 0.05). Loss of DcR3 impaired the growth and invasive property of HCC cell line of HepG2. Targeting DcR3 may be a potential therapeutic approach for the treatment of HCC.
Zhou, Xiao-Na; Li, Guang-Ming; Xu, Ying-Chen; Zhao, Tuan-Jie; Wu, Ji-Xiang
2016-01-01
Background: Decoy receptor 3 (DcR3) binds to Fas ligand (FasL) and inhibits FasL-induced apoptosis. The receptor is overexpressed in hepatocellular carcinoma (HCC), and it is associated with the growth and metastatic spread of tumors. DcR3 holds promises as a new target for the treatment of HCC, but little is known regarding the molecular mechanisms underlying the oncogenic properties of DcR3. The present work, therefore, examined the role of DcR3 in regulating the growth and invasive property of liver cancer cell HepG2. Methods: HepG2 cells were stably transfected with lentivirus-based short hairpin RNA vector targeting DcR3. After the knockdown of DcR3 was confirmed, cell proliferation, clone formation, ability of migrating across transwell membrane, and wound healing were assessed in vitro. Matrix metalloproteinase-9 (MMP 9) and vascular epithelial growth factor (VEGF)-C and D expressions of the DcR3 knockdown were also studied. Comparisons between multiple groups were done using one-way analysis of variance (ANOVA), while pairwise comparisons were performed using Student's t test. P < 0.05 was regarded statistically significant. Results: DcR3 was overexpressed in HepG2 compared to other HCC cell lines and normal hepatocyte Lo-2. Stable knockdown of DcR3 slowed down the growth of HepG2 (P < 0.05) and reduced the number of clones formed by 50% compared to those without DcR3 knockdown (P < 0.05). The knockdown also reduced the migration of HepG2 across transwell matrix membrane by five folds compared to the control (P < 0.05) and suppressed the closure of scratch wound (P < 0.05). In addition, the messenger RNA levels of MMP 9, VEGF-C, and VEGF-D were significantly suppressed by DcR3 knockdown by 90% when compared with the mock control (P < 0.05). Conclusions: Loss of DcR3 impaired the growth and invasive property of HCC cell line of HepG2. Targeting DcR3 may be a potential therapeutic approach for the treatment of HCC. PMID:27779171
Modeling and control of a brushless DC axial flow ventricular assist device.
Giridharan, Guruprasad A; Skliar, Mikhail; Olsen, Donald B; Pantalos, George M
2002-01-01
This article presents an integrated model of the human circulatory system that incorporates circulatory support by a brushless DC axial flow ventricular assist device (VAD), and a feedback VAD controller designed to maintain physiologically sufficient perfusion. The developed integrated model combines a network type model of the circulatory system with a nonlinear dynamic model of the brushless DC pump We show that maintaining a reference differential pressure between the left ventricle and aorta leads to adequate perfusion for different pathologic cases, ranging from normal heart to left heart asystole, and widely varying physical activity scenarios from rest to exercise.
Hargrove, Douglas L.
2004-09-14
A portable, hand-held meter used to measure direct current (DC) attenuation in low impedance electrical signal cables and signal attenuators. A DC voltage is applied to the signal input of the cable and feedback to the control circuit through the signal cable and attenuators. The control circuit adjusts the applied voltage to the cable until the feedback voltage equals the reference voltage. The "units" of applied voltage required at the cable input is the system attenuation value of the cable and attenuators, which makes this meter unique. The meter may be used to calibrate data signal cables, attenuators, and cable-attenuator assemblies.
QUANTITATIVE STUDY OF CLINAL VARIATION IN Juniperus virginiana USING TERPENOID DATA*
Flake, Robert H.; Rudloff, Ernst Von; Turner, B. L.
1969-01-01
Nine populations of Juniperus virginiana were sampled at approximately 150-mile intervals along a 1500-mile transect from northeastern Texas to Washington, D.C. Individual plants were examined for terpenoids by gas liquid chromatography and the resulting data analyzed by numerical classification methods using characters weighted according to their estimated variance in the natural populations. The results of the analysis show that these populations of J. virginiana cluster clinally from northeast to southwest, the more homogeneous populations occurring in the Appalachian region of North America; the more divergent populations found in progressively more distant regions, as measured along the transect from the northeast toward the southwest. No biochemical evidence could be found to support the hypothesis that hybridization with J. ashei might be causing this variability, as had been widely supposed previously. PMID:16591792
Integrated Inverter For Driving Multiple Electric Machines
Su, Gui-Jia [Knoxville, TN; Hsu, John S [Oak Ridge, TN
2006-04-04
An electric machine drive (50) has a plurality of inverters (50a, 50b) for controlling respective electric machines (57, 62), which may include a three-phase main traction machine (57) and two-phase accessory machines (62) in a hybrid or electric vehicle. The drive (50) has a common control section (53, 54) for controlling the plurality of inverters (50a, 50b) with only one microelectronic processor (54) for controlling the plurality of inverters (50a, 50b), only one gate driver circuit (53) for controlling conduction of semiconductor switches (S1-S10) in the plurality of inverters (50a, 50b), and also includes a common dc bus (70), a common dc bus filtering capacitor (C1) and a common dc bus voltage sensor (67). The electric machines (57, 62) may be synchronous machines, induction machines, or PM machines and may be operated in a motoring mode or a generating mode.
32 CFR 236.5 - Cyber security information sharing.
Code of Federal Regulations, 2014 CFR
2014-07-01
... forensics laboratory at DC3, which implements specialized handling procedures to maintain its accreditation as a digital and multimedia forensics laboratory. DC3 will maintain, control, and dispose of all...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Panbao; Lu, Xiaonan; Yang, Xu
This paper proposes an improved distributed secondary control scheme for dc microgrids (MGs), aiming at overcoming the drawbacks of conventional droop control method. The proposed secondary control scheme can remove the dc voltage deviation and improve the current sharing accuracy by using voltage-shifting and slope-adjusting approaches simultaneously. Meanwhile, the average value of droop coefficients is calculated, and then it is controlled by an additional controller included in the distributed secondary control layer to ensure that each droop coefficient converges at a reasonable value. Hence, by adjusting the droop coefficient, each participating converter has equal output impedance, and the accurate proportionalmore » load current sharing can be achieved with different line resistances. Furthermore, the current sharing performance in steady and transient states can be enhanced by using the proposed method. The effectiveness of the proposed method is verified by detailed experimental tests based on a 3 × 1 kW prototype with three interface converters.« less
NASA Technical Reports Server (NTRS)
Nixon, Douglas D.
2009-01-01
Discrete/Continuous (D/C) control theory is a new generalized theory of discrete-time control that expands the concept of conventional (exact) discrete-time control to create a framework for design and implementation of discretetime control systems that include a continuous-time command function generator so that actuator commands need not be constant between control decisions, but can be more generally defined and implemented as functions that vary with time across sample period. Because the plant/control system construct contains two linear subsystems arranged in tandem, a novel dual-kernel counter-flow convolution integral appears in the formulation. As part of the D/C system design and implementation process, numerical evaluation of that integral over the sample period is required. Three fundamentally different evaluation methods and associated algorithms are derived for the constant-coefficient case. Numerical results are matched against three available examples that have closed-form solutions.
DC-DC Type High-Frequency Link DC for Improved Power Quality of Cascaded Multilevel Inverter
NASA Astrophysics Data System (ADS)
Sadikin, Muhammad; Senjyu, Tomonobu; Yona, Atsushi
2013-06-01
Multilevel inverters are emerging as a new breed of power converter options for power system applications. Recent advances in power switching devices enabled the suitability of multilevel inverters for high voltage and high power applications because they are connecting several devices in series without the need of component matching. Usually, a transformerless battery energy storage system, based on a cascaded multilevel inverter, is used as a measure for voltage and frequency deviations. System can be reduced in size, weight, and cost of energy storage system. High-frequency link circuit topology is advantageous in realizing compact and light-weight power converters for uninterruptible power supply systems, new energy systems using photovoltaic-cells, fuel-cells and so on. This paper presents a DC-DC type high-frequency link DC (HFLDC) cascaded multilevel inverter. Each converter cell is implemented a control strategy for two H-bridge inverters that are controlled with the same multicarrier pulse width modulation (PWM) technique. The proposed cascaded multilevel inverter generates lower voltage total harmonic distortion (THD) in comparison with conventional cascaded multilevel inverter. Digital simulations are carried out using PSCAD/EMTDC to validate the performance of the proposed cascaded multilevel inverter.
Multiple DC, single AC converter with a switched DC transformer
Donnelly, M.K.; Hammerstrom, D.J.
1997-05-20
The invention is an improvement of the PASC inverter, wherein the improvements include the reduction from two shorting gates per transformer to one shorting gate per transformer and replacement of active control of the shorting gate with passive control of the shorting gate. Further advantages are obtained through the use of anti-parallel gate sets. 14 figs.
Multiple DC, single AC converter with a switched DC transformer
Donnelly, Matthew K.; Hammerstrom, Donald J.
1997-01-01
The invention is an improvement of the PASC inverter, wherein the improvements include the reduction from two shorting gates per transformer to one shorting gate per transformer and replacement of active control of the shorting gate with passive control of the shorting gate. Further advantages are obtained through the use of anti-parallel gate sets.
77 FR 44696 - Agency Forms Submitted for OMB Review, Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-30
... the social security equivalent and non- social security equivalent portions of Tier I, Tier II, vested... OMB control number of the ICR. For proper consideration of your comments, it is best if the RRB and... and Compensation Reports. OMB Control Number: 3220-0014. Form(s) submitted: DC-2 and DC-2a. Type of...
Kilburn, Jeremy M.; Lester, Scott C.; Lucas, John T.; Soike, Michael H.; Blackstock, A. William; Kearns, William T.; Hinson, William H.; Miller, Antonius A.; Petty, William J.; Munley, Michael T.; Urbanic, James J.
2014-01-01
Purpose/Objective(s) Regional failures occur in up to 15% of patients treated with stereotactic body radiotherapy (SBRT) for stage I/II lung cancer. This report focuses on the management of the unique scenario of isolated regional failures. Methods Patients treated initially with SBRT or accelerated hypo-fractionated radiotherapy were screened for curative intent treatment of isolated mediastinal failures (IMFs). Local control, regional control, progression-free survival, and distant control were estimated from the date of salvage treatment using the Kaplan–Meier method. Results Among 160 patients treated from 2002 to 2012, 12 suffered IMF and were amenable to salvage treatment. The median interval between treatments was 16 months (2–57 mo). Median salvage dose was 66 Gy (60–70 Gy). With a median follow-up of 10 months, the median overall survival was 15 months (95% confidence interval, 5.8–37 mo). When estimated from original treatment, the median overall survival was 38 months (95% confidence interval, 17–71 mo). No subsequent regional failures occurred. Distant failure was the predominant mode of relapse following salvage for IMF with a 2-year distant control rate of 38%. At the time of this analysis, three patients have died without recurrence while four are alive and no evidence of disease. High-grade toxicity was uncommon. Conclusions To our knowledge, this is first analysis of salvage mediastinal radiation after SBRT or accelerated hypofractionated radiotherapy in lung cancer. Outcomes appear similar to stage III disease at presentation. Distant failures were common, suggesting a role for concurrent or sequential chemotherapy. A standard full course of external beam radiotherapy is advisable in this unique clinical scenario. PMID:24736084
32 CFR 236.5 - Cyber security information sharing.
Code of Federal Regulations, 2013 CFR
2013-07-01
... multimedia forensics laboratory at DC3, which implements specialized handling procedures to maintain its accreditation as a digital and multimedia forensics laboratory. DC3 will maintain, control, and dispose of all...
32 CFR 236.5 - Cyber security information sharing.
Code of Federal Regulations, 2012 CFR
2012-07-01
... multimedia forensics laboratory at DC3, which implements specialized handling procedures to maintain its accreditation as a digital and multimedia forensics laboratory. DC3 will maintain, control, and dispose of all...
Codimension-Two Bifurcation Analysis in DC Microgrids Under Droop Control
NASA Astrophysics Data System (ADS)
Lenz, Eduardo; Pagano, Daniel J.; Tahim, André P. N.
This paper addresses local and global bifurcations that may appear in electrical power systems, such as DC microgrids, which recently has attracted interest from the electrical engineering society. Most sources in these networks are voltage-type and operate in parallel. In such configuration, the basic technique for stabilizing the bus voltage is the so-called droop control. The main contribution of this work is a codimension-two bifurcation analysis of a small DC microgrid considering the droop control gain and the power processed by the load as bifurcation parameters. The codimension-two bifurcation set leads to practical rules for achieving a robust droop control design. Moreover, the bifurcation analysis also offers a better understanding of the dynamics involved in the problem and how to avoid possible instabilities. Simulation results are presented in order to illustrate the bifurcation analysis.
Pollet, Thomas V; Roberts, Sam G B; Dunbar, Robin I M
2013-01-01
The theory of inclusive fitness has transformed our understanding of cooperation and altruism. However, the proximate psychological underpinnings of altruism are less well understood, and it has been argued that emotional closeness mediates the relationship between genetic relatedness and altruism. In this study, we use a real-life costly behaviour (travel time) to dissociate the effects of genetic relatedness from emotional closeness. Participants travelled further to see more closely related kin, as compared to more distantly related kin. For distantly related kin, the level of emotional closeness mediated this relationship--when emotional closeness was controlled for, there was no effect of genetic relatedness on travel time. However, participants were willing to travel further to visit parents, children and siblings as compared to more distantly related kin, even when emotional closeness was controlled for. This suggests that the mediating effect of emotional closeness on altruism varies with levels of genetic relatedness.
Non-linear control of the output stage of a solar microinverter
NASA Astrophysics Data System (ADS)
Lopez-Santos, Oswaldo; Garcia, Germain; Martinez-Salamero, Luis; Avila-Martinez, Juan C.; Seguier, Lionel
2017-01-01
This paper presents a proposal to control the output stage of a two-stage solar microinverter to inject real power into the grid. The input stage of the microinverter is used to extract the maximum available power of a photovoltaic module enforcing a power source behavior in the DC-link to feed the output stage. The work here reported is devoted to control a grid-connected power source inverter with a high power quality level at the grid side ensuring the power balance of the microinverter regulating the voltage of the DC-link. The proposed control is composed of a sinusoidal current reference generator and a cascade type controller composed by a current tracking loop and a voltage regulation loop. The current reference is obtained using a synchronized generator based on phase locked loop (PLL) which gives the shape, the frequency and phase of the current signal. The amplitude of the reference is obtained from a simple controller regulating the DC-link voltage. The tracking of the current reference is accomplished by means of a first-order sliding mode control law. The solution takes advantage of the rapidity and inherent robustness of the sliding mode current controller allowing a robust behavior in the regulation of the DC-link using a simple linear controller. The analytical expression to determine the power quality indicators of the micro-inverter's output is theoretically solved giving expressions relating the converter parameters. The theoretical approach is validated using simulation and experimental results.
Autologous tolerogenic dendritic cells for rheumatoid and inflammatory arthritis
Bell, G M; Anderson, A E; Diboll, J; Reece, R; Eltherington, O; Harry, R A; Fouweather, T; MacDonald, C; Chadwick, T; McColl, E; Dunn, J; Dickinson, A M; Hilkens, C M U; Isaacs, John D
2017-01-01
Objectives To assess the safety of intra-articular (IA) autologous tolerogenic dendritic cells (tolDC) in patients with inflammatory arthritis and an inflamed knee; to assess the feasibility and acceptability of the approach and to assess potential effects on local and systemic disease activities. Methods An unblinded, randomised, controlled, dose escalation Phase I trial. TolDC were differentiated from CD14+ monocytes and loaded with autologous synovial fluid as a source of autoantigens. Cohorts of three participants received 1×106, 3×106 or 10×106 tolDC arthroscopically following saline irrigation of an inflamed (target) knee. Control participants received saline irrigation only. Primary outcome was flare of disease in the target knee within 5 days of treatment. Feasibility was assessed by successful tolDC manufacture and acceptability via patient questionnaire. Potential effects on disease activity were assessed by arthroscopic synovitis score, disease activity score (DAS)28 and Health Assessment Questionnaire (HAQ). Immunomodulatory effects were sought in peripheral blood. Results There were no target knee flares within 5 days of treatment. At day 14, arthroscopic synovitis was present in all participants except for one who received 10×106 tolDC; a further participant in this cohort declined day 14 arthroscopy because symptoms had remitted; both remained stable throughout 91 days of observation. There were no trends in DAS28 or HAQ score or consistent immunomodulatory effects in peripheral blood. 9 of 10 manufactured products met quality control release criteria; acceptability of the protocol by participants was high. Conclusion IA tolDC therapy appears safe, feasible and acceptable. Knee symptoms stabilised in two patients who received 10×106 tolDC but no systemic clinical or immunomodulatory effects were detectable. Trial registration number NCT01352858. PMID:27117700
50 CFR 15.4 - Information collection requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Collection Control Officer, MS-222 ARLSQ, U.S. Fish and Wildlife Service, Washington, DC 20240, or the Office of Management and Budget, Paperwork Reduction Project (1018-0093), Washington, DC 20603. [63 FR 52634...
50 CFR 17.9 - Permit applications and information collection requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Information Collection Control Officer, MS-222 ARLSQ, U.S. Fish and Wildlife Service, Washington, DC 20240, or the Office of Management and Budget, Paperwork Reduction Project (1018-0093/0094), Washington, DC...
Hu, Dongzhi; Du, Changzheng; Xue, Weicheng; Dou, Fangyuan; Yao, Yunfeng; Gu, Jin
2013-08-01
The liver and lung are the organs most commonly affected by metastasis in colorectal cancer (CRC), and the interaction of chemokines and chemokine receptors (CKRs) plays an important role in the metastatic process. The aim of this study was to investigate the organ specificity of CKRs in CRC distant metastasis. Surgical specimens of primary tumours from 46 patients with metachronous distant metastases were retrieved retrospectively (20 lung metastases; 26 liver metastases). As a control, the records of 29 patients without distant metastases were randomly retrieved from our database, and their specimens were reassessed. The expression rates of CKRs, including CCR6, CXCR2, and CXCR4, were determined by immunohistochemistry, and were compared among the groups. The expression rates of CCR6 and CXCR2 were both significantly higher in the metastasis group than in the non-metastasis group (P < 0.05), but there was no statistical difference between the lung metastasis and liver metastasis subgroups. The expression of CXCR4 was not significantly different between the metastasis and non-metastasis groups. Multivariable analysis suggested that preoperative serum carcinoembryonic antigen level, CCR6 and CXCR2 were independent factors associated with distant metastasis. The expression of CCR6 and CXCR2 in CRC could predict metachronous distant metastasis, but they have no organ specificity for metastasis. © 2013 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Li, Jing; Tian, Xiubo; Gong, Chunzhi; Yang, Shiqin; Fu, Ricky K. Y.; Chu, Paul K.
2009-12-01
A hybrid radio-frequency (rf)/direct-current (dc) system has been developed to control the biasing effects during deposition of diamondlike carbon (DLC) films onto the inner wall of polyethylene terephthalate (PET) bottles. An additional dc bias is coupled to the rf electrode to produce the effect of equivalent rf self-biasing. This allows more flexible control of the deposition of the DLC films which are intended to improve the gas barrier characteristics. The experimental results demonstrate that the additional dc bias improves the adhesion strength between the DLC film and PET, although the enhancement in the gas barrier properties is not significantly larger compared to the one without dc bias. The apparatus and methodology have practical importance in the food and beverage industry.
Development of ATC for High Speed and High Density Commuter Line
NASA Astrophysics Data System (ADS)
Okutani, Tamio; Nakamura, Nobuyuki; Araki, Hisato; Irie, Shouji; Osa, Hiroki; Sano, Minoru; Ikeda, Keigo; Ozawa, Hiroyuki
A new ATC (Automatic Train Control) system has been developed with solutions to realize short train headway by assured braking utilizing digital data transmission via rails; the digital data for the ATP (Automatic Train Protection) function; and to achieve EMC features for both AC and DC sections. The DC section is of the unprecedented DC traction power supply system utilizing IGBT PWM converter at all DC substations. Within the AC section, train traction force is controlled by PWM converter/inverters. The carrier frequencies of the digital data signals and chopping frequency of PWM traction power converters on-board are decided via spectral analysis of noise up to degraded mode cases of equipment. Developed system was equipped to the Tukuba Express Line, new commuter line of Tokyo metropolitan area, and opened since Aug. 2005.
Iordachescu, Mihaela; Verlinden, Sven
2005-08-01
Using a combination of approaches, three EIN3-like (EIL) genes DC-EIL1/2 (AY728191), DC-EIL3 (AY728192), and DC-EIL4 (AY728193) were isolated from carnation (Dianthus caryophyllus) petals. DC-EIL1/2 deduced amino acid sequence shares 98% identity with the previously cloned and characterized carnation DC-EIL1 (AF261654), 62% identity with DC-EIL3, and 60% identity with DC-EIL4. DC-EIL3 deduced amino acid sequence shares 100% identity with a previously cloned carnation gene fragment, Dc106 (CF259543), 61% identity with Dianthus caryophyllus DC-EIL1 (AF261654), and 59% identity with DC-EIL4. DC-EIL4 shared 60% identity with DC-EIL1 (AF261654). Expression analyses performed on vegetative and flower tissues (petals, ovaries, and styles) during growth and development and senescence (natural and ethylene-induced) indicated that the mRNA accumulation of the DC-EIL family of genes in carnation is regulated developmentally and by ethylene. DC-EIL3 mRNA showed significant accumulation upon ethylene exposure, during flower development, and upon pollination in petals and styles. Interestingly, decreasing levels of DC-EIL3 mRNA were found in wounded leaves and ovaries of senescing flowers whenever ethylene levels increased. Flowers treated with sucrose showed a 2 d delay in the accumulation of DC-EIL3 transcripts when compared with control flowers. These observations suggest an important role for DC-EIL3 during growth and development. Changes in DC-EIL1/2 and DC-EIL4 mRNA levels during flower development, and upon ethylene exposure and pollination were very similar. mRNA levels of the DC-EILs in styles of pollinated flowers showed a positive correlation with ethylene production after pollination. The cloning and characterization of the EIN3-like genes in the present study showed their transcriptional regulation not previously observed for EILs.
Single Axis Attitude Control and DC Bus Regulation with Two Flywheels
NASA Technical Reports Server (NTRS)
Kascak, Peter E.; Jansen, Ralph H.; Kenny, Barbara; Dever, Timothy P.
2002-01-01
A computer simulation of a flywheel energy storage single axis attitude control system is described. The simulation models hardware which will be experimentally tested in the future. This hardware consists of two counter rotating flywheels mounted to an air table. The air table allows one axis of rotational motion. An inertia DC bus coordinator is set forth that allows the two control problems, bus regulation and attitude control, to be separated. Simulation results are presented with a previously derived flywheel bus regulator and a simple PID attitude controller.
Electric Drive Study. Volume 1
1987-12-21
CONDITIONER HIGH VOLTAGE DC ICONDITIONER 3 ,300-50 VOLT5), dCONTROL! Figure 5-4. Typical AC Drive System 20 system usable with an induction motor. The...controlling component in an AC drive is the motor power conditioner . This component changes the high voltage DC power to controlled AC power of...selected voltage and frequency which is applied to the drive motors. Since the vehicle gains stored energy as it is accelerated, the motor power conditioner
Vayro, Caitlin; Hamilton, Kyra
2016-03-01
In Australia, fruit and vegetable consumption is lower than recommended while discretionary foods (i.e., foods high in fat, sugar, and salt) are eaten in excess. Long-haul truck drivers are a group at risk of unhealthy eating but have received limited attention in the health literature. We aimed to examine long-haul truck drivers eating decisions in order to develop theory-based and empirically-driven health messages to improve their healthy food choices. Drawing on the Theory of Planned Behavior, three-phased formative research was conducted using self-report surveys. Phase 1 (N = 30, Mage = 39.53, SDage = 10.72) identified modal salient beliefs about fruit and vegetable (FV) intake and limiting discretionary choices (DC). There were nine behavioral and seven normative beliefs elicited for both FV and DC; while nine and five control beliefs were elicited for FV and DC, respectively. Phase 2 (N = 148, Mage = 44.23, SDage = 12.08) adopted a prospective design with one week follow-up to examine the predictors of FV and DC intention and behavior. A variety of behavioral and control beliefs were predictive of FV and DC intention and behavior. Normative beliefs were predictive of FV intention and behavior and DC intention only. Phase 3 (N = 20, Mage = 46.9, SDage = 12.85) elicited the reasons why each belief is held/solutions to negative beliefs, that could be used as health messages. In total, 40 reasons/solutions were identified: 26 for FV and 14 for DC. In summary, we found that specific behavioral, normative and control beliefs influenced FV and DC eating decisions. These results have implications for truck driver's health and provide formative research to inform future interventions to improve the food choices of a unique group who are at risk of unhealthy eating behaviors. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sun, Wen-Wen; Dou, Jin-Xia; Zhang, Lin; Qiao, Li-Kui; Shen, Na; Zhao, Qiang; Gao, Wen-Yuan
2017-07-11
This study aims to compare the efficacy of different treatments for nude mice transplanted with HT-29 colon carcinoma cell line. BalB/C nude mice were transplanted with HT-29 colon carcinoma cell line and randomly divided into four groups, with 5 mice in each group: blank control group, DC-CIK group, Huaier Granule group, and Huaier Granule group combined with DC-CIK group (combined treatment group). For DC-CIK group and combined treatment group, 1×106 DC-CIK cells were injected via the tail vein 4 days after transplantation. The injection was performed twice weekly for a total of 2 weeks. For Huaier Granule group and combined treatment group, Huaier Granule was administered at the dose of 20 g/60 g, by dissolving 20 g of Huaier granules in 600 ml of pure water. Intragastric administration of 0.2 ml of granules was performed once daily for 3 weeks. For the blank control group, equal volume of normal saline was given. Tumor size and body weight of nude mice were measured every 2 days during the 3-week treatment. The mice were sacrificed at the end of treatment to harvest tumors. Key genes of the signaling pathway were detected by RT-PCR. At the end of treatment, mice in combined treatment group, DC-CIK group and Huaier Granule group remained stable emotionally with normal mobility and water and food intake. However, in the blank control group, the mobility was restricted starting from the third week and the mice were on the verge of dying. The expression of PI3KR1, Akt, Wnt1, CTTNB1, Notch1, Notch2 and Notch3 genes were all downregulated significantly in the combined treatment group compared with DC-CIK group and Huaier Granule group (P<0.05). Therefore, the combined treatment of Huaier Granule combined with DC-CIK achieved the best effect in nude mice transplanted with HT-29 colon carcinoma cell line.
NASA Astrophysics Data System (ADS)
Yan, Huijie; Yang, Liang; Qi, Xiaohua; Ren, Chunsheng
2015-02-01
The effect of a DC bias on the electrohydrodynamics (EHD) force induced by a surface dielectric barrier AC discharge actuator for airflow control at the atmospheric pressure is investigated. The measurement of the surface potential due to charge deposition at different DC biases is carried out by using a special designed corona like discharge potential probe. From the surface potential data, the plasma electromotive force is shown not affected much by the DC biases except for some reduction of the DC bias near the exposed electrode edge for the sheath-like configuration. The total thrust is measured by an analytical balance, and an almost linear relationship to the potential voltage at the exposed electrode edge is found for the direct thrust force. The temporally averaged ionic wind characteristics are investigated by Pitot tube sensor and schlieren visualization system. It is found that the ionic wind velocity profiles with different DC biases are almost the same in the AC discharge plasma area but gradually diversified in the further downstream area as well as the upper space away from the discharge plasma area. Also, the DC bias can significantly modify the topology of the ionic wind produced by the AC discharge actuator. These results can provide an insight into how the DC biases to affect the force generation.
Effective switching frequency multiplier inverter
Su, Gui-Jia [Oak Ridge, TN; Peng, Fang Z [Okemos, MI
2007-08-07
A switching frequency multiplier inverter for low inductance machines that uses parallel connection of switches and each switch is independently controlled according to a pulse width modulation scheme. The effective switching frequency is multiplied by the number of switches connected in parallel while each individual switch operates within its limit of switching frequency. This technique can also be used for other power converters such as DC/DC, AC/DC converters.
A technological review on electric vehicle DC charging stations using photovoltaic sources
NASA Astrophysics Data System (ADS)
Youssef, Cheddadi; Fatima, Errahimi; najia, Es-sbai; Chakib, Alaoui
2018-05-01
Within the next few years, Electrified vehicles are destined to become the essential component of the transport field. Consequently, the charging infrastructure should be developed in the same time. Among this substructure, Charging stations photovoltaic-assisted are attracting a substantial interest due to increased environmental awareness, cost reduction and rise in efficiency of the PV modules. The intention of this paper is to review the technological status of Photovoltaic–Electric vehicle (PV-EV) charging stations during the last decade. The PV-EV charging station is divided into two categories, which are PV-grid and PV-standalone charging systems. From a practical point view, the distinction between the two architectures is the bidirectional inverter, which is added to link the station to the smart grid. The technological infrastructure includes the common hardware components of every station, namely: PV array, dc-dc converter provided with MPPT control, energy storage unit, bidirectional dc charger and inverter. We investigate, compare and evaluate many valuable researches that contain the design and control of PV-EV charging system. Additionally, this concise overview reports the studies that include charging standards, the power converters topologies that focus on the adoption of Vehicle-to grid technology and the control for both PV–grid and PV standalone DC charging systems.
Xu, Yan-Hong; Wang, Xing-De; Yang, Jia-Jun; Zhou, Li; Pan, Yong-Chao
2016-01-01
Autonomic dysfunction is common after stroke, which is correlated with unfavorable outcome. Phase-rectified signal averaging is a newly developed technique for assessing cardiac autonomic function, by detecting sympathetic and vagal nerve activity separately through calculating acceleration capacity (AC) and deceleration capacity (DC) of heart rate. In this study, we used this technique for the first time to investigate the cardiac autonomic function of patients with acute hemispheric ischemic stroke. A 24-hour Holter monitoring was performed in 63 patients with first-ever acute ischemic stroke in hemisphere and sinus rhythm, as well as in 50 controls with high risk of stroke. DC, AC, heart rate variability parameters, standard deviation of all normal-to-normal intervals (SDNN), and square root of the mean of the sum of the squares of differences between adjacent normal-to-normal intervals (RMSSD) were calculated. The National Institutes of Health Stroke Scale (NIHSS) was used to assess the severity of stroke. We analyzed the changes of DC, AC, SDNN, and RMSSD and also studied the correlations between these parameters and NIHSS scores. The R-R (R wave to R wave on electrocardiogram) intervals, DC, AC, and SDNN in the cerebral infarction group were lower than those in controls (P=0.003, P=0.002, P=0.006, and P=0.043), but the difference of RMSSD and the D-value and ratio between absolute value of AC (|AC|) and DC were not statistically significant compared with those in controls. The DC of the infarction group was significantly correlated with |AC|, SDNN, and RMSSD (r=0.857, r=0.619, and r=0.358; P=0.000, P=0.000, and P=0.004). Correlation analysis also showed that DC, |AC|, and SDNN were negatively correlated with NIHSS scores (r=-0.279, r=-0.266, and r=-0.319; P=0.027, P=0.035, and P=0.011). Both DC and AC of heart rate decreased in patients with hemispheric infarction, reflecting a decrease in both vagal and sympathetic modulation. Both DC and AC were correlated with the severity of stroke.
Serum decoy receptor 3 is a biomarker for disease severity in nonatopic asthma patients.
Chen, Ming-Han; Kan, Hung-Tsai; Liu, Chun-Yu; Yu, Wen-Kuang; Lee, Shinn-Shing; Wang, Jia-Horng; Hsieh, Shie-Liang
2017-01-01
Decoy receptor 3 (DcR3), a soluble receptor of the tumor necrosis factor receptor superfamily, is a pleiotropic immunomodulator. The aim of this study was to investigate serum DcR3 levels in atopic and nonatopic asthma patients. The serum DcR3 levels of 70 adults with asthma and 20 healthy controls were determined by enzyme-linked immunosorbent assay (ELISA). The asthma patients were divided into atopic and nonatopic subgroups, based on the presence or absence of immunoglobulin E (IgE) specific to allergen. Correlations between serum DcR3 levels and blood total-eosinophil counts, forced expiratory volume in 1 second (FEV1), FEV1/forced vital capacity (FVC), and Asthma Control Test (ACT) scores were analyzed. The mean serum DcR3 level was significantly higher in asthma patients than in healthy controls (266.1 ± 60.6 pg/mL vs. 63.7 ± 21.9 pg/mL, p = 0.003), but there was no significant difference between the mean serum DcR3 level of asthma patients with atopy (37 patients) and patients without atopy (33 patients; 298.7 ± 111.2 pg/mL vs. 230.6 ± 38.5 pg/mL, p = 0.064). However, the serum DcR3 level was positively correlated with the total eosinophil count (r = 0.448, p = 0.012) and inversely correlated with the percentages of predicted FEV1, FEV1/FVC, and ACT score (r = 0.409, p = 0.018; r = -0.399, p = 0.021; and r = -0.505, p = 0.003, respectively) in nonatopic asthma patients, but not in atopic patients. High serum DcR3 levels are associated with disease severity in nonatopic asthma patients, which suggests that DcR3 is a potential biomarker that can be used to predict the severity of nonatopic asthma. Copyright © 2016. Published by Elsevier B.V.
Acute and sub-acute oral toxicity of Dracaena cinnabari resin methanol extract in rats.
Al-Afifi, Nashwan Abdullah; Alabsi, Aied Mohammed; Bakri, Marina Mohd; Ramanathan, Anand
2018-02-05
Dracaena cinnabari (DC) is a perennial tree that located on the Southern coast of Yemen native to the Socotra Island. This tree produces a deep red resin known as the Dragon's blood, the Twobrother's Blood or Damm Alakhwain. The current study performed to evaluate the safety of the DC resin methanol extract after a single or 28 consecutive daily oral administrations. In assessing the safety of DC resin methanol extract, acute and sub-acute oral toxicity tests performed following OECD guidelines 423 and 407, respectively, with slight modifications. In acute oral toxicity test, DC resin methanol extract administered to female Sprague Dawley rats by oral gavage at a single dose of 300 and 2000 mg/kg body weight. Rats observed for toxic signs for 14 days. In sub-acute oral toxicity test, DC resin methanol extract administered to the rats by oral gavage at 500, 1000, and 1500 mg/kg body weight daily up to 28 days to male and female Spradgue Dawley rats. The control and high dose in satellite groups were also maintained and handled as the previous groups to determine the late onset toxicity of DC resin methanol extract. At the end of each test, hematological and biochemical analysis of the collected blood were performed as well as gross and microscopic pathology. In acute oral toxicity, no treatment-related death or toxic signs were observed. It revealed that the DC resin methanol extract could be well tolerated up to the dose 2000 mg/kg body weight and could be classified as Category 5. The sub-acute test observations indicated that there are no treatment-related changes up to the high dose level compared to the control. Food consumption, body weight, organ weight, hematological parameters, biochemical parameters and histopathological examination (liver, kidney, heart, spleen and lung) revealed no abnormalities. Water intake was significantly higher in the DC resin methanol extract treated groups compared to the control. This study demonstrates tolerability of DC resin methanol extract administered daily for 28 days up to 1500 mg/kg dose.
Aircraft Control Using Engine Thrust: A History of Learning TOC Real-Time
NASA Technical Reports Server (NTRS)
Cole, Jennifer H.; Batteas, Frank; Fullerton, Gordon
2006-01-01
A history of learning the operation of Throttles Only Control (TOC) to control an aircraft in real time using engine thrust is shown. The topics include: 1) Past TOC Accidents/Incidents; 2) 1972: DC-10 American Airlines; 3) May 1974: USAF B-52H; 4) April 1975: USAF C-5A; 5) April 1975: USAF C-5A; 6) 1981: USAF B-52G; 7) August 1985: JAL 123 B-747; 8) JAL 123 Survivor Story; 9) JAL 123 Investigation Findings; 10) July 1989: UAL 232 DC-10; 11) UAL 232 DC-10; 12) Eastwind 517 B-737; 13) November 2003: DHL A-300; 14) Historically, TOC has saved lives; 15) Automated Throttles-Only Control; 16) PCA Project; 17) Propulsion-Controlled Aircraft; 18) MD-11 PCA System and Flight Test Envelope; 19) MD-11 Simulation, PCA ILS-Soupled Landing Dispersion; 20) Throttles-Only Pitch and Roll Control Power; 21) PCA in Commercial Fleet; 22) Fall 2005: PCAR Project; 23) PCAR Background - TOC; and 24) PCAR Background - TOC.
Effects of Distant Reiki On Pain, Anxiety and Fatigue in Oncology Patients in Turkey: A Pilot Study.
Demir, Melike; Can, Gulbeyaz; Kelam, Ayhan; Aydıner, Aydın
2015-01-01
Fatigue, stress and pain are common symptoms among cancer patients, affecting the quality of life. The purpose of the present study was to determine the effect of distant Reiki on pain, anxiety and fatigue in oncology patients. Participants in the control group received usual medical and nursing care during their stay. The intervention group received usual care plus five distant Reiki sessions, one each night for 30 min. A face to face interview was performed and patient personal and illness related characteristics were evaluated using the Patient Characteristics form. Pain, stress and fatigue were evaluated according to a numeric rating scale. The experimental group was predominantly composed of women (71.4%), married individuals (40%), and primary school graduates (40%). The control group was predominantly male (72.7%), married (60%), and primary school graduates (60%). The control group demonstrated greater levels of pain (p=0.002), stress (p=0.001) and fatigue (p=0.001). The Reiki group pain score (p<0.0001), stress score (p<0.001) and fatigue score were also significantly lower. The results of this study indicate that Reiki may decreasepain, anxiety and fatigue in oncology patients.
Qualitative Characteristics of Depression in Parkinson's Patients and Controls.
Kritzinger, Cleo; Vollstedt, Eva-Juliane; Hückelheim, Katja; Lorwin, Anne; Graf, Julia; Tunc, Sinem; Klein, Christine; Kasten, Meike
2015-01-01
Depression is common in Parkinson's disease (PD); in light of typical PD pathology it may differ phenomenologically from depression in the general population. To assess depressive symptoms in PD patients and control groups and compare symptom profiles. After postal screening of 10,000 citizens of Lübeck, 642 participants were examined and the Beck Depression Inventory (BDI) was sufficiently answered by 477 subjects. Based on motor examinations, we distinguished PD patients, Healthy Controls (HC, no motor impairment), and Disease Controls (DC, motor impairment other than PD). The sample comprised 331 men and 311 women, aged 65 ± 8 years. Out of the overall sample, 198 (41.5%) had a BDI score ≥9. BDI results above 9 points occurred in 34.5% of HC, 50.3% of DC, and 42.4% of PD patients. Compared to the control groups (HC, DC) the PD patients endorsed more "dissatisfaction" and "loss of appetite" but less "feelings of guilt," "self-hate," and "loss of libido." Depressive symptoms are more frequent in PD patients compared to HC but not DC. Interestingly, the distribution of individual symptoms of the BDI differs between groups with an emphasis on loss of pleasure/enjoyment in the PD group, a symptom typically considered to be dopaminergically transmitted.
Electromagnetic phenomena analysis in brushless DC motor with speed control using PWM method
NASA Astrophysics Data System (ADS)
Ciurys, Marek Pawel
2017-12-01
Field-circuit model of a brushless DC motor with speed control using PWM method was developed. Waveforms of electrical and mechanical quantities of the designed motor with a high pressure vane pump built in a rotor of the motor were computed. Analysis of electromagnetic phenomena in the system: single phase AC network - converter - BLDC motor was carried out.
A brushless dc spin motor for momentum exchange altitude control
NASA Technical Reports Server (NTRS)
Stern, D.; Rosenlieb, J. W.
1972-01-01
Brushless dc spin motor is designed to use Hall effect probes as means of revolving rotor position and controlling motor winding currents. This results in 3 to 1 reduction in watt-hours required for wheel acceleration, a 2 to 1 reduction in power to run wheel, and a 10 to 1 reduction in the electronics size and weight.
Variable-frequency inverter controls torque, speed, and braking in ac induction motors
NASA Technical Reports Server (NTRS)
Nola, F. J.
1974-01-01
Dc to ac inverter provides optimum frequency and voltage to ac induction motor, in response to different motor-load and speed requirements. Inverter varies slip frequency of motor in proportion to required torque. Inverter protects motor from high current surges, controls negative slip to apply braking, and returns energy stored in momentum of load to dc power source.
NASA Technical Reports Server (NTRS)
Schoenfeld, A. D.; Yu, Y.
1973-01-01
The Analog Signal to Discrete Time Interval Converter microminiaturized module was utilized to control the signal conditioner power supplies. The multi-loop control provides outstanding static and dynamic performance characteristics, exceeding those generally associated with single-loop regulators. Eight converter boards, each containing three independent dc to dc converter, were built, tested, and delivered.
Zhang, W; Qi, X M; Chen, A X; Zhang, P; Cao, X C; Xiao, C H
2017-05-23
Objective: In this study, we evaluated the effect of supraclavicular lymph node dissection in breast cancer patients who presented with ipsilateral supraclavicular lymph node metastasis (ISLM) without distant metastasis. Methods: A total of 90 patients with synchronous ISLM without distant metastasis between 2000 and 2009 were retrospectively analyzed. Patients were retrospectively divided into two groups, namely supraclavicular lymph node dissection group(34 patients) and non-dissection group(56 patients), according to whether they underwentsupraclavicular lymph node dissection or not.The Kaplan-Meier method was applied to analyze the locoregional relapse free survival (LRFS) and overall survival(OS). Results: Median follow-upwas 85 months(range, 6 to 11 months). Local recurrence in 32 cases, 47 cases of distant metastasis, of which 25 patients were accompanied by both locoregional relapse and distant metastasis. Of the 32 patients with locoregional relapse, 11 patients were in the lymph node dissection group and 21 patients in the control group. Of the 47 patients with distant metastases, 17 were treated with lymph node dissection, 30 in the control group. Thirty-two patients died in the whole group and 16 patients underwentlymph node dissection and 16 patients didn't. There was no significant difference between the rate of 5-year LRFS and 5-year OS ( P =0.359, P =0.246). For patients of ER negative, the 5-year loco-regional relapse free survival rates were 63.7% and 43.3% in supraclavicular lymph node dissection group and control group, respectively. The 5-year overall survival rates were 52.1% and 52.3%, respectively, and there were no statistically significant differences ( P =0.118, P =0.951). For patients of PR negative, the 5-yearloco-regional relapse free rates were 59.8% and 46.2%, respectively, and the 5-year overall survival rates were 50.6% and 43.2%, respectively, and there was no significant difference between the two groups ( P =0.317, P =0.973). The 5-year recurrence-free survival rates of human epidermal growth factor receptor 2 (HER2)-positive patients were 61.2% and 48.0%( P =0.634), respectively, and the 5-year overall survival rates were 37.2% and 65.4%( P =0.032). Forty-seven patients suffered distant metastases and the 5-year metastases free survival rates were 37.3% and 38.5% in supraclavicular lymph node dissection group and control group, respectively. Conclusion: Supraclavicular lymph node dissection maybe an effective approach to improve the loco-regional control for the patients with ISLM, especially for ER negative and PR negative subtypes, but it might has adverseeffects for the patients with negative HER2 status.
The DC-SIGN-CD56 interaction inhibits the anti-dendritic cell cytotoxicity of CD56 expressing cells.
Nabatov, Alexey A; Raginov, Ivan S
2015-01-01
This study aimed to clarify interactions of the pattern-recognition receptor DC-SIGN with cells from the HIV-infected peripheral blood lymphocyte cultures. Cells from control and HIV-infected peripheral blood lymphocyte cultures were tested for the surface expression of DC-SIGN ligands. The DC-SIGN ligand expressing cells were analyzed for the role of DC-SIGN-ligand interaction in their functionality. In the vast majority of experiments HIV-infected lymphocytes did not express detectable DC-SIGN ligands on their cell surfaces. In contrast, non-infected cells, carrying NK-specific marker CD56, expressed cell surface DC-SIGN ligands. The weakly polysialylated CD56 was identified as a novel DC-SIGN ligand. The treatment of DC-SIGN expressing dendritic cells with anti-DC-SIGN antibodies increased the anti-dendritic cell cytotoxicity of CD56(pos) cells. The treatment of CD56(pos) cells with a peptide, blocking the weakly polysialylated CD56-specifc trans-homophilic interactions, inhibited their anti-dendritic cells cytotoxicity. The interaction between DC-SIGN and CD56 inhibits homotypic intercellular interactions of CD56(pos) cells and protects DC-SIGN expressing dendritic cells against CD56(pos) cell-mediated cytotoxicity. This finding can have an impact on the development of approaches to HIV infection and cancer therapy as well as in transplantation medicine.
Role of Dendritic Cells in the Pathogenesis of Whipple's Disease
Schinnerling, Katina; Geelhaar-Karsch, Anika; Allers, Kristina; Friebel, Julian; Conrad, Kristina; Loddenkemper, Christoph; Kühl, Anja A.; Erben, Ulrike; Ignatius, Ralf; Schneider, Thomas
2014-01-01
Accumulation of Tropheryma whipplei-stuffed macrophages in the duodenum, impaired T. whipplei-specific Th1 responses, and weak secretion of interleukin-12 (IL-12) are hallmarks of classical Whipple's disease (CWD). This study addresses dendritic cell (DC) functionality during CWD. We documented composition, distribution, and functionality of DC ex vivo or after in vitro maturation by fluorescence-activated cell sorting (FACS) and by immunohistochemistry in situ. A decrease in peripheral DC of untreated CWD patients compared to healthy donors was due to reduced CD11chigh myeloid DC (M-DC). Decreased maturation markers CD83, CD86, and CCR7, as well as low IL-12 production in response to stimulation, disclosed an immature M-DC phenotype. In vitro-generated monocyte-derived DC from CWD patients showed normal maturation and T cell-stimulatory capacity under proinflammatory conditions but produced less IL-12 and failed to activate T. whipplei-specific Th1 cells. In duodenal and lymphoid tissues, T. whipplei was found within immature DC-SIGN+ DC. DC and proliferating lymphocytes were reduced in lymph nodes of CWD patients compared to levels in controls. Our results indicate that dysfunctional IL-12 production by DC provides suboptimal conditions for priming of T. whipplei-specific T cells during CWD and that immature DC carrying T. whipplei contribute to the dissemination of the bacterium. PMID:25385798
Nonlinear control of voltage source converters in AC-DC power system.
Dash, P K; Nayak, N
2014-07-01
This paper presents the design of a robust nonlinear controller for a parallel AC-DC power system using a Lyapunov function-based sliding mode control (LYPSMC) strategy. The inputs for the proposed control scheme are the DC voltage and reactive power errors at the converter station and the active and reactive power errors at the inverter station of the voltage-source converter-based high voltage direct current transmission (VSC-HVDC) link. The stability and robust tracking of the system parameters are ensured by applying the Lyapunov direct method. Also the gains of the sliding mode control (SMC) are made adaptive using the stability conditions of the Lyapunov function. The proposed control strategy offers invariant stability to a class of systems having modeling uncertainties due to parameter changes and exogenous inputs. Comprehensive computer simulations are carried out to verify the proposed control scheme under several system disturbances like changes in short-circuit ratio, converter parametric changes, and faults on the converter and inverter buses for single generating system connected to the power grid in a single machine infinite-bus AC-DC network and also for a 3-machine two-area power system. Furthermore, a second order super twisting sliding mode control scheme has been presented in this paper that provides a higher degree of nonlinearity than the LYPSMC and damps faster the converter and inverter voltage and power oscillations. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Levens, Sara M; Armstrong, Laura Marie; Orejuela-Dávila, Ana I; Alverio, Tabitha
2017-09-01
Previous research suggests that adversity can have both adaptive and maladaptive effects, yet the emotional and working memory processes that contribute to more or less adaptive outcomes are unclear. The present study sought to investigate how updating emotional content differs in adolescents who have experienced past, recent, or no adversity. Participants who had experienced distant adversity (N = 53), no adversity (N = 58), or recent adversity only (N = 20) performed an emotion n-back task with emotional facial expressions. Results revealed that the distant adversity group exhibited significantly faster reaction times (RTs) than the no adversity and recent adversity only groups. In contrast, the recent adversity only group exhibited significantly slower RTs and more errors than the distant adversity and no adversity groups. These results suggest an emotion and executive control pathway by which both the benefits and negative effects of adversity may be conferred. Results also highlight the importance of time in assessing the impact of adversity.
NASA Astrophysics Data System (ADS)
Kodama, Shinya; Hori, Yoichi
It is well-known that the separately-excited DC motor has effective torque (current) reduction characteristics in response to rapid increase in the rotational speed of the motor. These characteristics have been utilized in adhesion control of electric railway trains with separately-excited DC motor. Up to now, we have proposed a new skid prevention method for EVs, utilizing these characteristics and have made experiments with the hardware skid simulator “Motor-Generator setup”. In this paper, we applied this skid prevention control to our new vehicle “UOT CADWELL EV" equipped with BLDC motors and showed its effectiveness.
Jiang, Bo; Grage-Griebenow, Evelin; Csernok, Elena; Butherus, Kristine; Ehlers, Stefan; Gross, Wolfgang L; Holle, Julia U
2010-01-01
The aim of the study was to assess PAR-2 expression on dendritic cell (DC) subsets and other immune cells of Wegener's granulomatosis (WG) patients and healthy controls (HC) and to investigate whether Proteinase 3 (PR3, a serine protease which can activate PAR2) induces maturation of human DC-like monocytes and murine Flt-3 ligand- and GM-CSF-generated DC. Human peripheral blood cells including DC subsets and Flt-3l- and GM-CSF-generated mouse DC were analysed for expression of PAR-2 and DC maturation markers by flow cytometry before and after stimulation with PR3, trypsin, PAR-2 agonist or LPS for 24 h. There was no difference of PAR-2 expression on PMNs, monocytes, lymphocytes and DC between all WG samples and HC. However, in inactive WG, expression of PAR-2 was downregulated on the cell surface of PMNs, monocytes, lymphocytes, and CD11c+DC compared to active WG and HC. PR3 and PAR2-agonists did not induce upregulation of PAR-2 or maturation markers of human DC-like monocytes in WG and HC. Likewise, murine PR3 did not induce upregulation of PAR-2 or maturation markers in murine DC. PAR-2 expression is downregulated on human peripheral blood cells including CD11c+ DC in inactive WG compared to active WG and HC, possibly reflecting a non-activated status of these cells in inactive disease. PR3 and PAR-2- agonists did not induce maturation of human ex vivo DC-like monocytes in WG and HC and of murine DC, suggesting this pathway is not singularly involved in the maturation of these cell subsets.
A HEL Testbed for High Accuracy Beam Pointing and Control
2009-07-01
Control by Dojong Kim, Duane Frist, Jae Jun Kim, Brij Agrawal 01 July 2009 Approved for......distant targets immediately. The issues of the technology on the HEL system include various types of high energy laser devices, beam control systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takei, Masao; Nakagawa, Hideyuki
The sea urchin Toxopneustes pileolus belonging to the family Toxopneustidae, they have well-developed globiferous pedicellariae with pharmacologically active substances. We have purified a novel sea urchin lectin-1 (SUL-1) from the large globiferous pedicellariae of T. pileolus. Dendritic cells (DC) are professional APC and play a pivotal role in controlling immune responses. This study investigated whether SUL-1 can drive DC maturation from human immature monocyte-derived DC in vitro. Human monocytes were cultured with GM-CSF and IL-4 for 6 days followed by another 1 day in the presence of SUL-1 or LPS. DC harvested on day 7 were examined using functional assays.more » The expression levels of CD1a, CD80, CD83, CD86 and HLA-DR as expressed by mean fluorescence intensity (MFI) on DC differentiated from immature DC after culture with 1.0 {mu}g/ml of SUL-1 for 1 day were enhanced and decreased endocytic activity. SUL-1-treated DC also displayed enhanced T cell stimulatory capacity in an MLR, as measured by T cell proliferation. Cell surface expression of CD80, CD83 and CD86 on SUL-1-treated DC was inhibited by anti-DC-SIGN mAb, while anti-DC-SIGN mAb had no influence on allogeneic T cell proliferation by SUL-1-treated DC. DC differentiated with SUL-1 induced the differentiation of naive T cell towards a helper T cell type 1 (Th1) response at DC/T (1:5) cells ratio depending on IL-12 secretion. In CTL assay, the production of IFN-{gamma} and {sup 51}Cr release on SUL-1-treated DC were more augmented than of immature DC or LPS-treated DC. SUL-1-treated DC expressed CCR7 and had a high migration to MIP-3{beta}. Intracellular Ca{sup 2+} mobilization in SUL-1-treated DC was also induced by MIP-3{beta}. These results suggest that SUL-1 bindings to DC-SIGN on surface of immature DC may lead to differentiate DC from immature DC. Moreover, it suggests that SUL-1 may be used on DC-based vaccines for cancer immunotherapy.« less
Control of epidemics on complex networks: Effectiveness of delayed isolation
NASA Astrophysics Data System (ADS)
Pereira, Tiago; Young, Lai-Sang
2015-08-01
We study isolation as a means to control epidemic outbreaks in complex networks, focusing on the consequences of delays in isolating infected nodes. Our analysis uncovers a tipping point: if infected nodes are isolated before a critical day dc, the disease is effectively controlled, whereas for longer delays the number of infected nodes climbs steeply. We show that dc can be estimated explicitly in terms of network properties and disease parameters, connecting lowered values of dc explicitly to heterogeneity in degree distribution. Our results reveal also that initial delays in the implementation of isolation protocols can have catastrophic consequences in heterogeneous networks. As our study is carried out in a general framework, it has the potential to offer insight and suggest proactive strategies for containing outbreaks of a range of serious infectious diseases.
Lightning Mapping Observations During DC3 in Northern Colorado
NASA Astrophysics Data System (ADS)
Krehbiel, P. R.; Rison, W.; Thomas, R. J.
2012-12-01
The Deep Convective Clouds and Chemistry Experiment (DC3) was conducted in three regions covered by Lightning Mapping Arrays (LMAs): Oklahoma and west Texas, northern Alabama, and northern Colorado. In this and a companion presentation, we discuss results obtained from the newly-deployed North Colorado LMA. The CO LMA revealed a surprising variety of lightning-inferred electrical structures, ranging from classic tripolar, normal polarity storms to several variations of anomalously electrified systems. Storms were often characterized by a pronounced lack or deficit of cloud-to-ground discharges (negative or positive), both in relative and absolute terms compared to the large amount of intracloud activity revealed by the LMA. Anomalous electrification was observed in small, localized storms as well as in large, deeply convective and severe storms. Another surprising observation was the frequent occurrence of embedded convection in the downwind anvil/outflow region of large storm systems. Observations of discharges in low flash rate situations over or near the network are sufficiently detailed to enable branching algorithms to estimate total channel lengths for modeling NOx production. However, this will not be possible in large or distant storm systems where the lightning was essentially continuous and structurally complex, or spatially noisy. Rather, a simple empirical metric for characterizing the lightning activity can be developed based on the number of located VHF radiation sources, weighted for example by the peak source power, source altitude, and temporal duration.
Multidimensional optimal droop control for wind resources in DC microgrids
NASA Astrophysics Data System (ADS)
Bunker, Kaitlyn J.
Two important and upcoming technologies, microgrids and electricity generation from wind resources, are increasingly being combined. Various control strategies can be implemented, and droop control provides a simple option without requiring communication between microgrid components. Eliminating the single source of potential failure around the communication system is especially important in remote, islanded microgrids, which are considered in this work. However, traditional droop control does not allow the microgrid to utilize much of the power available from the wind. This dissertation presents a novel droop control strategy, which implements a droop surface in higher dimension than the traditional strategy. The droop control relationship then depends on two variables: the dc microgrid bus voltage, and the wind speed at the current time. An approach for optimizing this droop control surface in order to meet a given objective, for example utilizing all of the power available from a wind resource, is proposed and demonstrated. Various cases are used to test the proposed optimal high dimension droop control method, and demonstrate its function. First, the use of linear multidimensional droop control without optimization is demonstrated through simulation. Next, an optimal high dimension droop control surface is implemented with a simple dc microgrid containing two sources and one load. Various cases for changing load and wind speed are investigated using simulation and hardware-in-the-loop techniques. Optimal multidimensional droop control is demonstrated with a wind resource in a full dc microgrid example, containing an energy storage device as well as multiple sources and loads. Finally, the optimal high dimension droop control method is applied with a solar resource, and using a load model developed for a military patrol base application. The operation of the proposed control is again investigated using simulation and hardware-in-the-loop techniques.
Progress on advanced dc and ac induction drives for electric vehicles
NASA Technical Reports Server (NTRS)
Schwartz, H. J.
1982-01-01
Progress is reported in the development of complete electric vehicle propulsion systems, and the results of tests on the Road Load Simulator of two such systems representative of advanced dc and ac drive technology are presented. One is the system used in the DOE's ETV-1 integrated test vehicle which consists of a shunt wound dc traction motor under microprocessor control using a transistorized controller. The motor drives the vehicle through a fixed ratio transmission. The second system uses an ac induction motor controlled by transistorized pulse width modulated inverter which drives through a two speed automatically shifted transmission. The inverter and transmission both operate under the control of a microprocessor. The characteristics of these systems are also compared with the propulsion system technology available in vehicles being manufactured at the inception of the DOE program and with an advanced, highly integrated propulsion system upon which technology development was recently initiated.
Multiphase High-Frequency Isolated DC-DC Converter for Industrial Applications
NASA Astrophysics Data System (ADS)
Maurya, Rakesh; Srivastava, S. P.; Agarwal, Pramod
2014-01-01
Industrial applications such as welding, plasma cutting, and surface hardening require a large DC current at low voltage. In such applications, the rating of power supply varies from few kilowatts to hundreds of kilowatts. The power supply employs in such applications particularly in arc welding process is expected to operate from open-circuit (no-load) to short-circuit (when the electrode sticks to the workpiece for a short span of time) quickly. In this paper, high-frequency isolated multiphase DC-DC converter is proposed which is well suited for aforementioned applications. Based on mathematical analysis, a simulation study with 5 kW, 5 V/1,000 A proposed model is carried out using Simulink block set and Sim Power System tool box and its performances are evaluated under symmetrical control methods. To verify the simulation results, scaled prototype model of rating 1.5 V/100 A is developed and tested with aforementioned control method under different operating conditions. In comparison with conventional welding power supply employed in many industries, the performance of proposed converter is improved significantly in terms of size and weight, efficiency and dynamic response.
[Developmental centered care. Evaluation of Spanish neonatal units].
Perapoch López, J; Pallás Alonso, C R; Linde Sillo, María A; Moral Pumarega, María T; Benito Castro, F; López Maestro, M; Caserío Carbonero, S; de la Cruz Bértolo, J
2006-02-01
Developmental and family centered care (DC) is a framework that aims to enhance the neurodevelopment of the infant. Over the last few years Spanish neonatal units have been working toward introducing this type of care. To evaluate DC in Spanish neonatal units by assessing certain features of the care provided to very low birth weight infants and their families. Spanish hospitals attending infants under 1,500 g were identified. A cross sectional study was performed using a telephone questionnaire with 25 DC-related items. Of the 100 hospitals attending infants under 1,500 g, 83 hospitals from all the Autonomous Communities in Spain participated in the survey. Of these, 31 % had noise pollution controls, 72 % controlled light intensity, 75 % bound the infants, and 29 % used saccharose as an analgesic. Ten percent allowed unrestricted parental visits. Twenty-two percent used kangaroo care without restriction. Sixty-three percent of the units reported difficulties when introducing DC-related changes. Practically all neonatal units have some type of DC activity, although in certain areas, such as unrestricted parental visits, the rate of implementation is low.
NASA Astrophysics Data System (ADS)
Liu, Houquan; Zhang, Xingchu
2017-03-01
In a semiconductor, optically excited electron-hole pairs, driven by a strong terahertz (THz) field, can recombine to create THz sidebands in the optical spectrum. The sideband spectrum exhibits a "plateau" up to a cutoff frequency of 3.17Up, where Up is the ponderomotive energy. In this letter, we predict that the bandwidth of this sideband spectrum plateau can be broadened by applying an additional direct-current (DC) electric field. We find that if applying a DC field of EDC=0.2ETHz (where EDC and ETHz are the amplitudes of the DC field and THz field, respectively), the sideband spectrum presents three plateaus with 5.8Up, 10.05Up and 16Up being the cutoff frequencies of the first, second and third plateaus, respectively. This bandwidth broadening occurs because the DC field can increase the kinetic energy that an electron-hole pair can gain from the THz field. This effect means that the bandwidth of the sideband spectrum can be controlled flexibly by changing the DC field, thereby facilitating the ultrafast electro-optical applications of THz sideband generation.
Maximum power point tracking for photovoltaic applications by using two-level DC/DC boost converter
NASA Astrophysics Data System (ADS)
Moamaei, Parvin
Recently, photovoltaic (PV) generation is becoming increasingly popular in industrial applications. As a renewable and alternative source of energy they feature superior characteristics such as being clean and silent along with less maintenance problems compared to other sources of the energy. In PV generation, employing a Maximum Power Point Tracking (MPPT) method is essential to obtain the maximum available solar energy. Among several proposed MPPT techniques, the Perturbation and Observation (P&O;) and Model Predictive Control (MPC) methods are adopted in this work. The components of the MPPT control system which are P&O; and MPC algorithms, PV module and high gain DC-DC boost converter are simulated in MATLAB Simulink. They are evaluated theoretically under rapidly and slowly changing of solar irradiation and temperature and their performance is shown by the simulation results, finally a comprehensive comparison is presented.
Utilizing zero-sequence switchings for reversible converters
Hsu, John S.; Su, Gui-Jia; Adams, Donald J.; Nagashima, James M.; Stancu, Constantin; Carlson, Douglas S.; Smith, Gregory S.
2004-12-14
A method for providing additional dc inputs or outputs (49, 59) from a dc-to-ac inverter (10) for controlling motor loads (60) comprises deriving zero-sequence components (V.sub.ao, V.sub.bo, and V.sub.co) from the inverter (10) through additional circuit branches with power switching devices (23, 44, 46), transforming the voltage between a high voltage and a low voltage using a transformer or motor (42, 50), converting the low voltage between ac and dc using a rectifier (41, 51) or an H-bridge (61), and providing at least one low voltage dc input or output (49, 59). The transformation of the ac voltage may be either single phase or three phase. Where less than a 100% duty cycle is acceptable, a two-phase modulation of the switching signals controlling the inverter (10) reduces switching losses in the inverter (10). A plurality of circuits for carrying out the invention are also disclosed.
Design of 5 V DC to 20 V DC switching regulator for power supply module
NASA Astrophysics Data System (ADS)
Azmi, N. A.; Murad, S. A. Z.; Harun, A.; Ismail, R. C.; Isa, M. N. M.; Zulkifeli, M. A.
2017-09-01
This paper presents the design of 5 V to 20 V DC switching regulator for power supply module. A voltage multiplier which consists of cascaded diode-capacitor combination is used in order to obtain a high voltage power supply. Due to power loss that has occurred in a stray of component arrangement, the proposed design employs a pulse width modulation (PWM) controller circuit with an inclusion of a capacitor, diode, and inductor components. The input supply of 5 V DC to LT1618 controller circuit has produced 20.35 V based from simulation results. Meanwhile, the measurement results of 19.36 V are obtained and the feedback signal is required for the purpose of stabilizing the output. The proposed design can reduce the components as well as the PCB size, thus minimizing the overall cost of making a switching regulator for power supply module.
Electronics for Deep Space Cryogenic Applications
NASA Technical Reports Server (NTRS)
Patterson, R. L.; Hammond, A.; Dickman, J. E.; Gerber, S. S.; Elbuluk, M. E.; Overton, E.
2002-01-01
Deep space probes and planetary exploration missions require electrical power management and control systems that are capable of efficient and reliable operation in very cold temperature environments. Typically, in deep space probes, heating elements are used to keep the spacecraft electronics near room temperature. The utilization of power electronics designed for and operated at low temperature will contribute to increasing efficiency and improving reliability of space power systems. At NASA Glenn Research Center, commercial-off-the-shelf devices as well as developed components are being investigated for potential use at low temperatures. These devices include semiconductor switching devices, magnetics, and capacitors. Integrated circuits such as digital-to-analog and analog-to-digital converters, DC/DC converters, operational amplifiers, and oscillators are also being evaluated. In this paper, results will be presented for selected analog-to-digital converters, oscillators, DC/DC converters, and pulse width modulation (PWM) controllers.
Design of an Input-Parallel Output-Parallel LLC Resonant DC-DC Converter System for DC Microgrids
NASA Astrophysics Data System (ADS)
Juan, Y. L.; Chen, T. R.; Chang, H. M.; Wei, S. E.
2017-11-01
Compared with the centralized power system, the distributed modularized power system is composed of several power modules with lower power capacity to provide a totally enough power capacity for the load demand. Therefore, the current stress of the power components in each module can then be reduced, and the flexibility of system setup is also enhanced. However, the parallel-connected power modules in the conventional system are usually controlled to equally share the power flow which would result in lower efficiency in low loading condition. In this study, a modular power conversion system for DC micro grid is developed with 48 V dc low voltage input and 380 V dc high voltage output. However, in the developed system control strategy, the numbers of power modules enabled to share the power flow is decided according to the output power at lower load demand. Finally, three 350 W power modules are constructed and parallel-connected to setup a modular power conversion system. From the experimental results, compared with the conventional system, the efficiency of the developed power system in the light loading condition is greatly improved. The modularized design of the power system can also decrease the power loss ratio to the system capacity.
Requirements for a transformerless power conditioning system
NASA Technical Reports Server (NTRS)
Klein, J.; Koerner, T.; Rippel, W.; Kalbach, J.
1984-01-01
Requirements for development of a Transformerless Power Conditioning Subsystem (TPCS) that will meet utility, manufacturer, and customer needs are detailed. Issues analyzed include current utility guidelines, safety and grounding issues that appear as local codes, various kinds of TPCS connections that can be developed, dc injection, and a brief survey of TPCS circuit topologies that will meet requirements. The major result is that a finite time exists for control operation before dc injection into the distribution transformer causes customer outage (on the order of seconds). This time permits the control system to sense a dc injection condition and remove the TPCS from the utility system. Requirements for such a control system are specified. A three wire connection will ensure balanced operation for customer loads and two wire connections caused average value dc to be injected into single phase loads. This type of connection also allows for the lowest array voltage. The conclusion is that requirements for a TPCS can be determined and that there are not showstopping issues preventing implementation. The actual design and topology of the TPCS was left for further study.
DC-9 Flight Demonstration Program with Refanned JT8D Engines. Volume 3; Performance and Analysis
NASA Technical Reports Server (NTRS)
1975-01-01
The JT8D-109 engine has a sea level static, standard day bare engine takeoff thrust of 73,840 N. At sea level standard day conditions the additional thrust of the JT8D-109 results in 2,040 kg additional takeoff gross weight capability for a given field length. Range loss of the DC-9 Refan airplane for long range cruise was determined. The Refan airplane demonstrated stall, static longitudinal stability, longitudinal control, longitudinal trim, minimum control speeds, and directional control characteristics similar to the DC-9-30 production airplane and complied with airworthiness requirements. Cruise, climb, and thrust reverser performance were evaluated. Structural and dynamic ground test, flight test and analytical results substantiate Refan Program requirements that the nacelle, thrust reverser hardware, and the airplane structural modifications are flightworthy and certifiable and that the airplane meets flutter speed margins. Estimated unit cost of a DC-9 Refan retrofit program is 1.338 million in mid-1975 dollars with about an equal split in cost between airframe and engine.
NASA Technical Reports Server (NTRS)
Abel, I.; Newsom, J. R.
1981-01-01
Two flutter suppression control laws were synthesized, implemented, and tested on a low speed aeroelastic wing model of a DC-10 derivative. The methodology used to design the control laws is described. Both control laws demonstrated increases in flutter speed in excess of 25 percent above the passive wing flutter speed. The effect of variations in gain and phase on the closed loop performance was measured and compared with analytical predictions. The analytical results are in good agreement with experimental data.
De Trez, Carl; Schneider, Kirsten; Potter, Karen; Droin, Nathalie; Fulton, James; Norris, Paula S; Ha, Suk-won; Fu, Yang-Xin; Murphy, Theresa; Murphy, Kenneth M; Pfeffer, Klaus; Benedict, Chris A; Ware, Carl F
2008-01-01
Proliferation of dendritic cells (DC) in the spleen is regulated by positive growth signals through the lymphotoxin (LT)-beta receptor; however, the countering inhibitory signals that achieve homeostatic control are unresolved. Mice deficient in LTalpha, LTbeta, LTbetaR, and the NFkappaB inducing kinase show a specific loss of CD8- DC subsets. In contrast, the CD8alpha- DC subsets were overpopulated in mice deficient in the herpesvirus entry mediator (HVEM) or B and T lymphocyte attenuator (BTLA). HVEM- and BTLA-deficient DC subsets displayed a specific growth advantage in repopulating the spleen in competitive replacement bone marrow chimeric mice. Expression of HVEM and BTLA were required in DC and in the surrounding microenvironment, although DC expression of LTbetaR was necessary to maintain homeostasis. Moreover, enforced activation of the LTbetaR with an agonist Ab drove expansion of CD8alpha- DC subsets, overriding regulation by the HVEM-BTLA pathway. These results indicate the HVEM-BTLA pathway provides an inhibitory checkpoint for DC homeostasis in lymphoid tissue. Together, the LTbetaR and HVEM-BTLA pathways form an integrated signaling network regulating DC homeostasis.
λ-Carrageenan improves the antitumor effect of dendritic cellbased vaccine.
Li, Jinyao; Aipire, Adila; Li, Jinyu; Zhu, Hongge; Wang, Yanping; Guo, Wenjia; Li, Xiaoqin; Yang, Jia; Liu, Chunling
2017-05-02
In this study, we investigated the effect of λ-carrageenan on the maturation and function of dendritic cells (DCs) and its adjuvant effect on DC-based vaccine. We found that λ-carrageenan dose-dependently decreased the endocytosis of DCs, promoted DC maturation and increased cytokine production through TLR4 mediated signaling pathway. λ-carrageenan treatment also enhanced the ability of DCs in the stimulating allogenic splenocyte proliferation. In TC-1 tumor mouse model, HPV peptides pulsed λ-carrageenan-DC (HPV-CGN-DC) significantly inhibited tumor growth compared with control group. The frequencies of CD4+ and CD8+ T cells in spleens of tumor mice and their activation status were significantly increased in HPV-CGN-DC group, but the frequencies of natural regulatory T cells and CD11b+Gr-1+ cells were significantly decreased. Further, HPV-CGN-DC induced strong CD8+ T cell responses, which are negatively correlated with tumor volumes. The results suggested that λ-carrageenan promoted DC maturation through TLR4 signaling pathway and could be used as the adjuvant in DC-based vaccines.
Cascaded Quadruple Active Bridge Structures for Multilevel DC to Three-Phase AC Conversion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Brian B; Achanta, Prasanta K; Maksimovic, Dragan
This paper introduces a multilevel architecture comprised of interconnected dc to three-phase ac converter units. To enable series connected operation, each converter unit contains a quadruple active bridge (QAB) converter that provides isolation between the dc side and each of the three ac sides. Since each converter unit transfers dc-side power as constant balanced three-phase power on the ac side, this implies instantaneous input-output power balance and allows elimination of bulk capacitive energy storage. In addition to minimizing required capacitance, the proposed approach simultaneously enables simplified dc-link controllers amenable to decentralized implementation, supports bidirectional power transfer, and exhibits a modularmore » structure to enhance scalability. Isolation provided by the QAB allows a wide range of electrical configurations among multiple units in various dc-ac, ac-dc or ac-ac applications. In this paper, the focus is on series connections on the ac side to emphasize multilevel operation, and the approach is experimentally validated in a dc-ac system containing two cascaded converter units.« less
Research on DC Micro-grid system of photovoltaic power generation
NASA Astrophysics Data System (ADS)
Zheng, Yiming; Wang, Xiaohui
2018-01-01
The use of energy has become a topic of concern, the demand of people for power grows in number or quantity with the development of economy. It is necessary to consider using new forms of power supply-microgrid system for distributed power supply. The power supply mode can not only effectively solve the problem of excessive line loss in the large power grid, but also can increase the reliability of the power supply, and is economical and environmental friendly. With the increasing of DC loads, in order to improve the utilization efficiency, the DC microgrid power supply problems are begin to be researched and integrated with the renewable energy sources. This paper researched the development of microgrid, compared AC microgrid with DC microgrid, summarized the distribution of DC bus voltage level, the DC microgrid network form, the control mode and the main power electronics elements of DC microgrid of photovoltaic power generation system. Today, the DC microgrid system is still in the development stage without uniform voltage level standard, however, it will come into service in the future.
A single serving of caffeinated coffee impairs postprandial glucose metabolism in overweight men.
Robertson, Tracey M; Clifford, Michael N; Penson, Simon; Chope, Gemma; Robertson, M Denise
2015-10-28
Previous studies regarding the acute effects of coffee on glycaemic control have used a single large dose of coffee, typically containing the caffeine equivalent of 2-4 servings of coffee. This study investigates whether the acute effects of coffee are dose-dependent, starting with a single serving. A total of ten healthy overweight males participated in a two-part randomised double-blind cross-over study. In the first part, they ingested 2, 4 or 8 g instant decaffeinated coffee (DC) dissolved in 400 ml water with caffeine added in proportion to the DC (total 100, 200 or 400 mg caffeine) or control (400 ml water) all with 50 g glucose. In the second part, they ingested the same amounts of DC (2, 4, 8 g) or control, but with a standard 100 mg caffeine added to each. Capillary blood samples were taken every 15 min for 2 h after each drink and glucose and insulin levels were measured. Repeated measures ANOVA on glucose results found an effect when caffeine was varied in line with DC (P=0·008). Post hoc analysis revealed that both 2 and 4 g DC with varied caffeine content increased the glycaemic response v. There was no effect of escalating doses of DC when caffeine remained constant at 100 mg. These results demonstrate that one standard serving of coffee (2 g) is sufficient to affect glucose metabolism. Furthermore, the amount of caffeine found in one serving (100 mg) is sufficient to mask any potential beneficial effects of increasing other components. No dose-dependent effect was found.
Power-Quality Improvement in PFC Bridgeless SEPIC-Fed BLDC Motor Drive
NASA Astrophysics Data System (ADS)
Singh, Bhim; Bist, Vashist
2013-06-01
This article presents a design of a power factor correction (PFC)-based brushless DC (BLDC) motor drive. The speed control of BLDC motor is achieved by controlling the DC link voltage of the voltage source inverter (VSI) feeding BLDC motor using a single voltage sensor. A front-end bridgeless single-ended primary inductance converter (SEPIC) is used for DC link voltage control and PFC operation. A bridgeless SEPIC is designed to operate in discontinuous inductor current mode (DICM) thus utilizing a simple control scheme of voltage follower. An electronic commutation of BLDC motor is used for VSI to operate in a low-frequency operation for reduced switching losses in the VSI. Moreover, a bridgeless topology offers less conduction losses due to absence of diode bridge rectifier for further increasing the efficiency. The proposed BLDC motor drive is designed to operate over a wide range of speed control with an improved power-quality at the AC mains under the recommended international power-quality standards such as IEC 61000-3-2.
NASA Astrophysics Data System (ADS)
Liu, Hongbo; Liu, Haihan; Liu, Sitong; Peng, Huanhuan
2018-06-01
The VSC-HVDC connection system will be the effective transmission method for the large scale and long distance integrated wind farm. Because of the fluctuating power, the DC voltage will be over-voltage or under-voltage in transmission line which will affect the steady operation of the wind power integrating system. In order to mitigate the DC voltage variation of the grid-connected inverter on the grid side and improve the dynamic response of the system, a load current feed-forward control scheme is put forward. Firstly, this paper analyses stability of a system without additional feed-forward control based on double close loop. Secondly, the load current which can indicate the power changes is introduced to counteract the fluctuation of DC voltage in the improvement control scheme. By simulating the results show that the proposed control strategy can improve the dynamic response performance and mitigate the fluctuation of the active power output of the wind farm.
Magnetic Amplifier-Based Power-Flow Controller
Dimitrovski, Aleksandar; Li, Zhi; Ozpineci, Burak
2015-02-05
The concept of the magnetic amplifier, a common electromagnetic device in electronic applications in the past, has seldom been used in power systems. In this paper, we introduce the magnetic amplifier-based power-flow controller (MAPFC), an innovative low-cost device that adopts the idea of the magnetic amplifier for power-flow control applications. The uniqueness of MAPFC is in the use of the magnetization of the ferromagnetic core, shared by an ac and a dc winding, as the medium to control the ac winding reactance inserted in series with the transmission line to be controlled. Large power flow in the line can bemore » regulated by the small dc input to the dc winding. Moreover, a project on the R&D of an MAPFC has been funded by the U.S. Department of Energy (DOE) and conducted by the Oak Ridge National Laboratory (ORNL), the University of Tennessee-Knoxville, and Waukesha Electric Systems, Inc. since early 2012. Findings from the project are presented along with some results obtained in a laboratory environment.« less
Antu, Kalathookunnel Antony; Riya, Mariam Philip; Mishra, Arvind; Sharma, Sharad; Srivastava, Arvind K; Raghu, Kozhiparambil Gopalan
2014-09-01
The beneficial effects of hydroethanol extract of Symplocos cochinchinensis (SCE) has been explored against hyperglycemia associated secondary complications in streptozotocin induced diabetic rat model. The experimental groups consist of normal control (NC), diabetic control (DC), DC + metformin 100 mg kg(-1) bwd, DC + SCE 250 and DC + SCE 500. SCEs and metformin were administered daily for 21 days and sacrificed on day 22. Oral glucose tolerance test, plasma insulin, % HbA1c, urea, creatinine, aspartate aminotransferase, alanine aminotransferase, albumin, total protein etc. were analysed. Aldose reductase (AR) activity in the eye lens was also checked. On day 21, DC rats showed significantly abnormal glucose response, HOMA-IR, % HbA1c, decreased activity of antioxidant enzymes and GSH, elevated AR activity, hepatic and renal oxidative stress markers like malondialdehyde, protein carbonyls compared to NC. DC rats also exhibited increased level of plasma urea and creatinine. Treatment with SCE protected from the deleterious alterations of biochemical parameters in a dose dependent manner including histopathological alterations in pancreas. SCE 500 exhibited 46.28% of glucose lowering effect and decreased HOMA-IR (2.47), % HbA1c (6.61), lens AR activity (15.99%), and hepatic, renal oxidative stress and function markers compared to DC group. Considerable amount of liver and muscle glycogen was replenished by SCE treatment in diabetic animals. Although metformin showed better effect, the activity of SCE was very much comparable with this drug. Copyright © 2014 Elsevier GmbH. All rights reserved.
Kho, Steven; Marfurt, Jutta; Noviyanti, Rintis; Kusuma, Andreas; Piera, Kim A; Burdam, Faustina H; Kenangalem, Enny; Lampah, Daniel A; Engwerda, Christian R; Poespoprodjo, Jeanne R; Price, Ric N; Anstey, Nicholas M; Minigo, Gabriela; Woodberry, Tonia
2015-08-01
Clinical illness with Plasmodium falciparum or Plasmodium vivax compromises the function of dendritic cells (DC) and expands regulatory T (Treg) cells. Individuals with asymptomatic parasitemia have clinical immunity, restricting parasite expansion and preventing clinical disease. The role of DC and Treg cells during asymptomatic Plasmodium infection is unclear. During a cross-sectional household survey in Papua, Indonesia, we examined the number and activation of blood plasmacytoid DC (pDC), CD141(+), and CD1c(+) myeloid DC (mDC) subsets and Treg cells using flow cytometry in 168 afebrile children (of whom 15 had P. falciparum and 36 had P. vivax infections) and 162 afebrile adults (of whom 20 had P. falciparum and 20 had P. vivax infections), alongside samples from 16 patients hospitalized with uncomplicated malaria. Unlike DC from malaria patients, DC from children and adults with asymptomatic, microscopy-positive P. vivax or P. falciparum infection increased or retained HLA-DR expression. Treg cells in asymptomatic adults and children exhibited reduced activation, suggesting increased immune responsiveness. The pDC and mDC subsets varied according to clinical immunity (asymptomatic or symptomatic Plasmodium infection) and, in asymptomatic infection, according to host age and parasite species. In conclusion, active control of asymptomatic infection was associated with and likely contingent upon functional DC and reduced Treg cell activation. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Brushless direct-current motor with stationary armature and field
NASA Technical Reports Server (NTRS)
Studer, P. A.
1970-01-01
Electronically commutated dc motor has an active fixed field winding, and active fixed armature winding, and passive rotor. By use of brushless dc motor switching technique, motor provides continuous controllable and reversible torque without use of sliding contacts.
Kilovolt dc solid state remote power controller development
NASA Technical Reports Server (NTRS)
Mitchell, J. T.
1982-01-01
The experience gained in developing and applying solid state power controller (SSPC) technology at high voltage dc (HVDC) potentials and power levels of up to 25 kilowatts is summarized. The HVDC switching devices, power switching concepts, drive circuits, and very fast acting overcurrent protection circuits were analyzed. A 25A bipolar breadboard with Darlington connected switching transistor was built. Fault testing at 900 volts was included. A bipolar transistor packaged breadboard design was developed. Power MOSFET remote power controller (RPC) was designed.
Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network
Zhu, Zhenshan; Liu, Dichen; Liao, Qingfen; ...
2018-01-26
With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); softmore » open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.« less
Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Zhenshan; Liu, Dichen; Liao, Qingfen
With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); softmore » open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.« less
Dissociative complexity: Antecedents and clinical correlates of a new construct.
Briere, John; Dietrich, Anne; Semple, Randye J
2016-09-01
To the extent that dissociation is a multidimensional phenomenon, and given a growing literature on complex posttraumatic outcomes, we hypothesized a new construct: dissociative complexity (DC). DC is defined as the tendency to simultaneously endorse multiple, relatively independent dissociative dimensions into their clinical ranges, and therefore represents the overall breadth or complexity of an individual's dissociative response. DC was evaluated in general population and prison participants using the Multiscale Dissociation Inventory (MDI; Briere, 2002). DC was higher among prisoners and women, and, as hypothesized, was associated with cumulative trauma and serious comorbidities (suicidality and substance abuse), even when controlling for generally elevated dissociation. DC appears to be a meaningful clinical construct that is phenomenologically and empirically different from a unidimensional index of dissociative severity. DC may serve as a clinical marker for multiple trauma exposures, complex dissociative outcomes, and risk of problematic comorbidities. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Analysis and Countermeasure Study on DC Bias of Main Transformer in a City
NASA Astrophysics Data System (ADS)
Wang, PengChao; Wang, Hongtao; Song, Xinpu; Gu, Jun; Liu, yong; Wu, weili
2017-07-01
According to the December 2015 Guohua Beijing thermal power transformer DC magnetic bias phenomenon, the monitoring data of 24 hours of direct current is analyzed. We find that the maximum DC current is up to 25 and is about 30s for the trend cycle, on this basis, then, of the geomagnetic storm HVDC and subway operation causes comparison of the mechanism, and make a comprehensive analysis of the thermal power plant’s geographical location, surrounding environment and electrical contact etc.. The results show that the main reason for the DC bias of Guohua thermal power transformer is the operation of the subway, and the change of the DC bias current is periodic. Finally, of Guohua thermal power transformer DC magnetic bias control method is studied, the simulation results show that the method of using neutral point with small resistance or capacitance can effectively inhibit the main transformer neutral point current.
Simulation and Performance of Brushless DC Motor Actuators.
1985-12-01
4. MacMillan, P.M., "A CSMP Commutation Model for Design Study of a ’.... Brushless DC Motor Power Conditioner for a Cruise Missile Fin Control...8217. ,. ~-4..T NPS69-85-028 .r * N NAVAL POSTGRADUATE SCHOOL Monterey, California DTIC FEB4 1986 SIMULATION AND PERFORMANCE OF BRUSHLESS DC...S. TYPE OF REPORT & PERIOD COVERED Progress Re rSimulation and Performance of Brushless DCPrgesRpt Motor Actuators 111 PERFORMING ORG. REPORT NUMBER
Dendritic cells in chronic myelomonocytic leukaemia.
Vuckovic, S; Fearnley, D B; Gunningham, S; Spearing, R L; Patton, W N; Hart, D N
1999-06-01
Blood dendritic cells (DC) differentiate in vitro via two separate pathways: either directly from blood DC precursors (DCp) or from CD14+ monocytes. In chronic myelomonocytic leukaemia (CMML) abnormal bone marrow precursors contribute to blood monocyte development but DC development has not been studied previously. Monocytes comprised 60% of blood MNC in 15 CMML patients studied, compared with 20% in 16 age-matched controls. The increase in blood monocytes was accompanied by a reciprocal decrease in mean blood DC percentage (from 0.42% of MNC in normal individuals to 0.16% of MNC in CMML patients). Absolute blood DC numbers showed a minimal (non-significant) reduction from 9.8 x 10(6)/l in normal individuals to 7.5 x 10(6)/l in CMML patients. The CD14(low) WCD16+ monocyte subpopulation was not found in CMML patients. After culture in GM-CSF/IL-4, CMML CD14+ monocytes acquired the phenotype of immature monocyte derived DC (Mo-DC) with similar yields to normal blood Mo-DC generation. Addition of TNF-alpha or LPS induced both normal and CMML Mo-DC to express prominent dendritic processes, the CMRF44+ and CD83+ antigens and high levels of HLA-DR, CD80 and CD86. Treatment either with TNF-alpha or LPS increased the allostimulatory activity of normal Mo-DC, but had little effect on the allostimulatory activity of CMML Mo-DC, perhaps reflecting the underlying neoplastic changes in monocyte precursors. We conclude that the blood DC numbers are relatively unaffected in CMML, suggesting discrete regulation of monocyte and DC production.
Mankour, Mohamed; Khiat, Mounir; Ghomri, Leila; Chaker, Abdelkader; Bessalah, Mourad
2018-06-01
This paper presents modeling and study of 12-pulse HVDC (High Voltage Direct Current) based on real time simulation where the HVDC inverter is connected to a weak AC system. In goal to study the dynamic performance of the HVDC link, two serious kind of disturbance are applied at HVDC converters where the first one is the single phase to ground AC fault and the second one is the DC link to ground fault. The study is based on two different mode of analysis, which the first is to test the performance of the DC control and the second is focalized to study the effect of the protection function on the system behavior. This real time simulation considers the strength of the AC system to witch is connected and his relativity with the capacity of the DC link. The results obtained are validated by means of RT-lab platform using digital Real time simulator Hypersim (OP-5600), the results carried out show the effect of the DC control and the influence of the protection function to reduce the probability of commutation failures and also for helping inverter to take out from commutation failure even while the DC control fails to eliminate them. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
Moro, L N; Hiriart, M I; Buemo, C; Jarazo, J; Sestelo, A; Veraguas, D; Rodriguez-Alvarez, L; Salamone, D F
2015-07-01
The aim of this study was to evaluate the capacity of domestic cat (Dc, Felis silvestris) oocytes to reprogram the nucleus of cheetah (Ch, Acinonyx jubatus) cells by interspecies SCNT (iSCNT), by using embryo aggregation. Dc oocytes were in vitro matured and subjected to zona pellucida free (ZP-free) SCNT or iSCNT, depending on whether the nucleus donor cell was of Dc or Ch respectively. ZP-free reconstructed embryos were then cultured in microwells individually (Dc1X and Ch1X groups) or in couples (Dc2X and Ch2X groups). Embryo aggregation improved in vitro development obtaining 27.4, 47.7, 16.7 and 28.3% of blastocyst rates in the Dc1X, Dc2X, Ch1X and Ch2X groups, respectively (P<0.05). Moreover, aggregation improved the morphological quality of blastocysts from the Dc2X over the Dc1X group. Gene expression analysis revealed that Ch1X and Ch2X blastocysts had significantly lower relative expression of OCT4, CDX2 and NANOG than the Dc1X, Dc2X and IVF control groups. The OCT4, NANOG, SOX2 and CDX2 genes were overexpressed in Dc1X blastocysts, but the relative expression of these four genes decreased in the Dc2X, reaching similar relative levels to those of Dc IVF blastocysts. In conclusion, Ch blastocysts were produced using Dc oocytes, but with lower relative expression of pluripotent and trophoblastic genes, indicating that nuclear reprogramming could be still incomplete. Despite this, embryo aggregation improved the development of Ch and Dc embryos, and normalized Dc gene expression, which suggests that this strategy could improve full-term developmental efficiency of cat and feline iSCNT embryos. © 2015 Society for Reproduction and Fertility.
Lin, Wan-Wan; Hsieh, Shie-Liang
2011-04-01
Recently, several decoy molecules belonging to tumor necrosis factor receptor superfamily (TNFRSF) have been identified, including decoy receptor 1 (DcR1), decoy receptor 2 (DcR2), and decoy receptor 3 (DcR3). One of the tumor necrosis factor superfamily (TNFSF) members, TNF-related apoptosis-inducing ligand (TRAIL), binds to DcR1 and DcR2, which are membranous receptors with a truncated cytoplasmic domain, thus unable to transduce TRAIL-mediated signaling. In contrast to DcR1 and DcR2, DcR3 is a soluble receptor capable of neutralizing the biological effects of three other TNFSF members: Fas ligand (FasL/TNFSF6/CD95L), LIGHT (TNFSF14) and TNF-like molecule 1A (TL1A/TNFSF15). Since FasL is a potent apoptosis- and inflammation-inducing factor, LIGHT is involved in apoptosis and inflammation, and TL1A is a T cell costimulator and is involved in gut inflammation, DcR3 can be defined as an immunomodulator on the basis of its neutralizing effects on FasL, LIGHT, and TL1A. Initial studies demonstrated that DcR3 expression is elevated in tumors cells; however, later work showed that DcR3 expression is also upregulated in inflammatory diseases, where serum DcR3 levels correlate with disease progression. In addition to its neutralizing effect, DcR3 also acts as an effector molecule to modulate cell function via 'non-decoy' activities. This review focuses on the immunomodulatory effects of DcR3 via 'decoy' and 'non-decoy' functions, and discusses the potential of DcR3 as a biomarker to predict cancer invasion and inflammation progression. We also discuss the possible utility of recombinant DcR3 as a therapeutic agent to control autoimmune diseases, as well as the potential to attenuate tumor progression by inhibiting DcR3 expression. Copyright © 2011 Elsevier Inc. All rights reserved.
Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System
NASA Astrophysics Data System (ADS)
Cen, Zhaohui
2017-09-01
Gird-connected Photo-Voltaic (PV) systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT) is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.
Automatic quadrature control and measuring system
NASA Technical Reports Server (NTRS)
Hamlet, J. F.
1973-01-01
Quadrature is separated from amplified signal by use of phase detector, with phase shifter providing appropriate reference. Output of phase detector is further amplified and filtered by dc amplifier. Output of dc amplifier provides signal to neutralize quadrature component of transducer signal.
Frequency-Offset Cartesian Feedback Based on Polyphase Difference Amplifiers
Zanchi, Marta G.; Pauly, John M.; Scott, Greig C.
2010-01-01
A modified Cartesian feedback method called “frequency-offset Cartesian feedback” and based on polyphase difference amplifiers is described that significantly reduces the problems associated with quadrature errors and DC-offsets in classic Cartesian feedback power amplifier control systems. In this method, the reference input and feedback signals are down-converted and compared at a low intermediate frequency (IF) instead of at DC. The polyphase difference amplifiers create a complex control bandwidth centered at this low IF, which is typically offset from DC by 200–1500 kHz. Consequently, the loop gain peak does not overlap DC where voltage offsets, drift, and local oscillator leakage create errors. Moreover, quadrature mismatch errors are significantly attenuated in the control bandwidth. Since the polyphase amplifiers selectively amplify the complex signals characterized by a +90° phase relationship representing positive frequency signals, the control system operates somewhat like single sideband (SSB) modulation. However, the approach still allows the same modulation bandwidth control as classic Cartesian feedback. In this paper, the behavior of the polyphase difference amplifier is described through both the results of simulations, based on a theoretical analysis of their architecture, and experiments. We then describe our first printed circuit board prototype of a frequency-offset Cartesian feedback transmitter and its performance in open and closed loop configuration. This approach should be especially useful in magnetic resonance imaging transmit array systems. PMID:20814450
A control strategy for PV stand-alone applications
NASA Astrophysics Data System (ADS)
Slouma, S.; Baccar, H.
2015-04-01
This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.
EVA Metro Sedan electric-propulsion system: test and evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reimers, E.
1979-09-01
The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on themore » dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.« less
Method and apparatus for pulse width modulation control of an AC induction motor
Geppert, Steven; Slicker, James M.
1984-01-01
An inverter is connected between a source of DC power and a three-phase AC induction motor, and a micro-processor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .THETA., where .THETA. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands of electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a "flyback" DC-DC converter circuit for recharging the battery.
Luz, Maria; Manzey, Dietrich; Modemann, Susanne; Strauss, Gero
2015-01-01
Image-guided navigation (IGN) systems provide automation support of intra-operative information analysis and decision-making for surgeons. Previous research showed that navigated-control (NC) systems which represent high levels of decision-support and directly intervene in surgeons' workflow provide benefits with respect to patient safety and surgeons' physiological stress but also involve several cost effects (e.g. prolonged surgery duration, reduced secondary-task performance). It was hypothesised that less automated distance-control (DC) systems would provide a better solution in terms of human performance consequences. N = 18 surgeons performed a simulated mastoidectomy with NC, DC and without IGN assistance. Effects on surgical performance, physiological effort, workload and situation awareness (SA) were compared. As expected, DC technology had the same benefits as the NC system but also led to less unwanted side effects on surgery duration, subjective workload and SA. This suggests that IGN systems just providing information analysis support are overall more beneficial than higher automated decision-support. This study investigates human performance consequences of different concepts of IGN support for surgeons. Less automated DC systems turned out to provide advantages for patient safety and surgeons' stress similar to higher automated NC systems with, at the same time, reduced negative consequences on surgery time and subjective workload.
Closed Loop Fuzzy Logic Controlled PV Based Cascaded Boost Five-Level Inverter System
NASA Astrophysics Data System (ADS)
Revana, Guruswamy; Kota, Venkata Reddy
2018-04-01
Recent developments in intelligent control methods and power electronics have produced PV based DC to AC converters related to AC drives. Cascaded boost converter and inverter find their way in interconnecting PV and Induction Motor. This paper deals with digital simulation and implementation of closed loop controlled five-level inverter based Photo-Voltaic (PV) system. The objective of this work is to reduce the harmonics using Multi Level Inverter based system. The DC output from the PV panel is boosted using cascaded-boost-converters. The DC output of these cascaded boost converters is applied to the bridges of the cascaded inverter. The AC output voltage is obtained by the series cascading of the output voltage of the two inverters. The investigations are done with Induction motor load. Cascaded boost-converter is proposed in the present work to produce the required DC Voltage at the input of the bridge inverter. A simple FLC is applied to CBFLIIM system. The FLC is proposed to reduce the steady state error. The simulation results are compared with the hardware results. The results of the comparison are made to show the improvement in dynamic response in terms of settling time and steady state error. Design procedure and control strategy are presented in detail.
High-performance fractional order terminal sliding mode control strategy for DC-DC Buck converter
Xu, Dan; Zhou, Huan; Bai, Anning; Lu, Wei
2017-01-01
This paper presents an adaption of the fractional order terminal sliding mode control (AFTSMC) strategy for DC-DC Buck converter. The following strategy aims to design a novel nonlinear sliding surface function, with a double closed-loop structure of voltage and current. This strategy is a fusion of two characteristics: terminal sliding mode control (TSMC) and fractional order calculation (FOC). In addition, the influence of “the controller parameters” on the “performance of double closed-loop system” is investigated. It is observed that the value of terminal power has to be chosen to make a compromise between start-up and transient response of the converter. Therefore the AFTSMC strategy chooses the value of the terminal power adaptively, and this strategy can lead to the appropriate number of fractional order as well. Furthermore, through the fractional order analysis, the system can reach the sliding mode surface in a finite time. And the theoretical considerations are verified by numerical simulation. The performance of the AFTSMC and TSMC strategies is tested by computer simulations. And the comparison simulation results show that the AFTSMC exhibits a considerable improvement in terms of a faster output voltage response during load changes. Moreover, AFTSMC obtains a faster dynamical response, smaller steady-state error rate and lower overshoot. PMID:29084255
Closed Loop Fuzzy Logic Controlled PV Based Cascaded Boost Five-Level Inverter System
NASA Astrophysics Data System (ADS)
Revana, Guruswamy; Kota, Venkata Reddy
2017-12-01
Recent developments in intelligent control methods and power electronics have produced PV based DC to AC converters related to AC drives. Cascaded boost converter and inverter find their way in interconnecting PV and Induction Motor. This paper deals with digital simulation and implementation of closed loop controlled five-level inverter based Photo-Voltaic (PV) system. The objective of this work is to reduce the harmonics using Multi Level Inverter based system. The DC output from the PV panel is boosted using cascaded-boost-converters. The DC output of these cascaded boost converters is applied to the bridges of the cascaded inverter. The AC output voltage is obtained by the series cascading of the output voltage of the two inverters. The investigations are done with Induction motor load. Cascaded boost-converter is proposed in the present work to produce the required DC Voltage at the input of the bridge inverter. A simple FLC is applied to CBFLIIM system. The FLC is proposed to reduce the steady state error. The simulation results are compared with the hardware results. The results of the comparison are made to show the improvement in dynamic response in terms of settling time and steady state error. Design procedure and control strategy are presented in detail.
High-performance fractional order terminal sliding mode control strategy for DC-DC Buck converter.
Wang, Jianlin; Xu, Dan; Zhou, Huan; Bai, Anning; Lu, Wei
2017-01-01
This paper presents an adaption of the fractional order terminal sliding mode control (AFTSMC) strategy for DC-DC Buck converter. The following strategy aims to design a novel nonlinear sliding surface function, with a double closed-loop structure of voltage and current. This strategy is a fusion of two characteristics: terminal sliding mode control (TSMC) and fractional order calculation (FOC). In addition, the influence of "the controller parameters" on the "performance of double closed-loop system" is investigated. It is observed that the value of terminal power has to be chosen to make a compromise between start-up and transient response of the converter. Therefore the AFTSMC strategy chooses the value of the terminal power adaptively, and this strategy can lead to the appropriate number of fractional order as well. Furthermore, through the fractional order analysis, the system can reach the sliding mode surface in a finite time. And the theoretical considerations are verified by numerical simulation. The performance of the AFTSMC and TSMC strategies is tested by computer simulations. And the comparison simulation results show that the AFTSMC exhibits a considerable improvement in terms of a faster output voltage response during load changes. Moreover, AFTSMC obtains a faster dynamical response, smaller steady-state error rate and lower overshoot.
Method and apparatus for pulse width modulation control of an AC induction motor
NASA Technical Reports Server (NTRS)
Geppert, Steven (Inventor); Slicker, James M. (Inventor)
1984-01-01
An inverter is connected between a source of DC power and a three-phase AC induction motor, and a micro-processor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .THETA., where .THETA. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands of electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a flyback DC-DC converter circuit for recharging the battery.
Design and experiment of vehicular charger AC/DC system based on predictive control algorithm
NASA Astrophysics Data System (ADS)
He, Guangbi; Quan, Shuhai; Lu, Yuzhang
2018-06-01
For the car charging stage rectifier uncontrollable system, this paper proposes a predictive control algorithm of DC/DC converter based on the prediction model, established by the state space average method and its prediction model, obtained by the optimal mathematical description of mathematical calculation, to analysis prediction algorithm by Simulink simulation. The design of the structure of the car charging, at the request of the rated output power and output voltage adjustable control circuit, the first stage is the three-phase uncontrolled rectifier DC voltage Ud through the filter capacitor, after by using double-phase interleaved buck-boost circuit with wide range output voltage required value, analyzing its working principle and the the parameters for the design and selection of components. The analysis of current ripple shows that the double staggered parallel connection has the advantages of reducing the output current ripple and reducing the loss. The simulation experiment of the whole charging circuit is carried out by software, and the result is in line with the design requirements of the system. Finally combining the soft with hardware circuit to achieve charging of the system according to the requirements, experimental platform proved the feasibility and effectiveness of the proposed predictive control algorithm based on the car charging of the system, which is consistent with the simulation results.
Shobharani, M; Viraktamath, C A; Webb, M D
2018-01-02
Species of the leafhopper genus Penthimia Germar known from the Indian subcontinent are reviewed based on the examination of type specimens. Seven new species of the genus, Penthimia curvata sp. nov. (Karnataka: Bandipur), P. meghalayensis sp. nov. (Meghalaya: Nangpoh), P. neoattenuata sp. nov. (India: Tamil Nadu), P. ribhoi sp. nov. (India: Meghalaya), P. sahyadrica sp. nov. (Karnataka: Dharmasthala, Agumbe; Kerala: Thekkady), P. spiculata sp. nov. (Karnataka: Nagarahole) and P. tumida sp. nov. (Tamil Nadu: Ootacamund; Kerala: Munnar) are described. The following nomenclatorial changes are proposed: Penthimia alba Zahniser, McKamey Dmitriev, 2012 (replacement name for P. thoracica Distant, 1918, nec Panzer, 1799), syn. nov. of P. quadrinotata Distant, 1918; Neodartus scutellatus Distant, 1908 syn. nov. of Penthimia ereba Distant 1908; P. nilgiriensis Distant, 1918 syn. nov. of P. montana Distant, 1918; P. scutellata (Distant) comb. nov. (from genus Neodartus); a lectotype is designated for P. maculosa Distant, stat. revived, thereby removing its synonymy with P. scapularis Distant. The following other lectotypes are designated: P. attenuata Distant, P. subniger Distant, P. scapularis Distant, P. distanti Baker, P. ereba Distant, N. scutellatus Distant, P. fraterna Distant, P. funebris Distant, P. juno Distant, P. maculosa Distant, P. montana Distant, P. noctua Distant, P. quadrinotata Distant, P. alba Zahniser, McKamey Dmitriev. Examination of types of Penthimia rufopunctata Motschulsky revealed that it belongs to Penthimia and hence it is transferred back to that genus from Neodartus, revised placement. The following species previously included in the genus Penthimia are transferred to the genera Tambila Distant and Vulturnus Kirkaldy: Tambila badia (Distant) comb. nov., T. majuscula (Distant) comb. nov., T. vittatifrons (Distant) comb. nov., T. variabilis (Distant) comb. nov. and Vulturnus flavocapitata (Distant) comb. nov. Three species are treated in a new Penthimia compacta Walker complex, i.e., Penthimia compacta Walker 1851, Penthimia subniger Distant 1908 and Penthimia scapularis Distant 1908. All taxa are described and a key to Penthimiini genera found in the subcontinent and also a key to species of Penthimia are included.
Design of power electronics for TVC EMA systems
NASA Technical Reports Server (NTRS)
Nelms, R. Mark
1993-01-01
The Composite Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently developing a class of electromechanical actuators (EMA's) for use in space transportation applications such as thrust vector control (TVC) and propellant control valves (PCV). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 volts. MSFC has selected the brushless dc motor for implementation in EMA's. This report presents the results of an investigation into the applicability of two new technologies, MOS-controlled thyristors (MCT's) and pulse density modulation (PDM), to the control of brushless dc motors in EMA systems. MCT's are new power semiconductor devices, which combine the high voltage and current capabilities of conventional thyristors and the low gate drive requirements of metal oxide semiconductor field effect transistors (MOSFET's). The commanded signals in a PDM system are synthesized using a series of sinusoidal pulses instead of a series of square pulses as in a pulse width modulation (PWM) system. A resonant dc link inverter is employed to generate the sinusoidal pulses in the PDM system. This inverter permits zero-voltage switching of all semiconductors which reduces switching losses and switching stresses. The objectives of this project are to develop and validate an analytical model of the MCT device when used in high power motor control applications and to design, fabricate, and test a prototype electronic circuit employing both MCT and PDM technology for controlling a brushless dc motor.
CANISTER TRANSFER SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Gorpani
2000-06-23
The Canister Transfer System receives transportation casks containing large and small disposable canisters, unloads the canisters from the casks, stores the canisters as required, loads them into disposal containers (DCs), and prepares the empty casks for re-shipment. Cask unloading begins with cask inspection, sampling, and lid bolt removal operations. The cask lids are removed and the canisters are unloaded. Small canisters are loaded directly into a DC, or are stored until enough canisters are available to fill a DC. Large canisters are loaded directly into a DC. Transportation casks and related components are decontaminated as required, and empty casks aremore » prepared for re-shipment. One independent, remotely operated canister transfer line is provided in the Waste Handling Building System. The canister transfer line consists of a Cask Transport System, Cask Preparation System, Canister Handling System, Disposal Container Transport System, an off-normal canister handling cell with a transfer tunnel connecting the two cells, and Control and Tracking System. The Canister Transfer System operating sequence begins with moving transportation casks to the cask preparation area with the Cask Transport System. The Cask Preparation System prepares the cask for unloading and consists of cask preparation manipulator, cask inspection and sampling equipment, and decontamination equipment. The Canister Handling System unloads the canister(s) and places them into a DC. Handling equipment consists of a bridge crane hoist, DC loading manipulator, lifting fixtures, and small canister staging racks. Once the cask has been unloaded, the Cask Preparation System decontaminates the cask exterior and returns it to the Carrier/Cask Handling System via the Cask Transport System. After the DC is fully loaded, the Disposal Container Transport System moves the DC to the Disposal Container Handling System for welding. To handle off-normal canisters, a separate off-normal canister handling cell is located adjacent to the canister transfer cell and is interconnected to the transfer cell by means of the off-normal canister transfer tunnel. All canister transfer operations are controlled by the Control and Tracking System. The system interfaces with the Carrier/Cask Handling System for incoming and outgoing transportation casks. The system also interfaces with the Disposal Container Handling System, which prepares the DC for loading and subsequently seals the loaded DC. The system support interfaces are the Waste Handling Building System and other internal Waste Handling Building (WHB) support systems.« less
Kageyama, Ken; Yamamoto, Akira; Okuma, Tomohisa; Hamamoto, Shinichi; Takeshita, Toru; Sakai, Yukimasa; Nishida, Norifumi; Matsuoka, Toshiyuki; Miki, Yukio
2013-10-01
To evaluate survival and distant tumor growth after radiofrequency ablation (RFA) and local OK-432 injection at a single tumor site in a rabbit model with intra- and extrahepatic VX2 tumors and to examine the effect of this combination therapy, which we termed immuno-radiofrequency ablation (immunoRFA), on systemic antitumor immunity in a rechallenge test. Our institutional animal care committee approved all experiments. VX2 tumors were implanted to three sites: two in the liver and one in the left ear. Rabbits were randomized into four groups of seven to receive control, RFA alone, OK-432 alone, and immunoRFA treatments at a single liver tumor at 1 week after implantation. Untreated liver and ear tumor volumes were measured after the treatment. As the rechallenge test, tumors were reimplanted into the right ear of rabbits, which survived the 35 weeks and were followed up without additional treatment. Statistical significance was examined by log-rank test for survival and Student's t test for tumor volume. Survival was significantly prolonged in the immunoRFA group compared to the other three groups (P < 0.05). Untreated liver and ear tumor sizes became significantly smaller after immunoRFA compared to controls (P < 0.05). In the rechallenge test, the reimplanted tumors regressed without further therapy compared to the ear tumors of the control group (P < 0.05). ImmunoRFA led to improved survival and suppression of distant untreated tumor growth. Decreases in size of the distant untreated tumors and reimplanted tumors suggested that systemic antitumor immunity was enhanced by immunoRFA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kageyama, Ken, E-mail: kageyamaken0112@gmail.com; Yamamoto, Akira, E-mail: loveakirayamamoto@gmail.com; Okuma, Tomohisa, E-mail: o-kuma@msic.med.osaka-cu.ac.jp
Purpose: To evaluate survival and distant tumor growth after radiofrequency ablation (RFA) and local OK-432 injection at a single tumor site in a rabbit model with intra- and extrahepatic VX2 tumors and to examine the effect of this combination therapy, which we termed immuno-radiofrequency ablation (immunoRFA), on systemic antitumor immunity in a rechallenge test. Methods: Our institutional animal care committee approved all experiments. VX2 tumors were implanted to three sites: two in the liver and one in the left ear. Rabbits were randomized into four groups of seven to receive control, RFA alone, OK-432 alone, and immunoRFA treatments at amore » single liver tumor at 1 week after implantation. Untreated liver and ear tumor volumes were measured after the treatment. As the rechallenge test, tumors were reimplanted into the right ear of rabbits, which survived the 35 weeks and were followed up without additional treatment. Statistical significance was examined by log-rank test for survival and Student's t test for tumor volume. Results: Survival was significantly prolonged in the immunoRFA group compared to the other three groups (P < 0.05). Untreated liver and ear tumor sizes became significantly smaller after immunoRFA compared to controls (P < 0.05). In the rechallenge test, the reimplanted tumors regressed without further therapy compared to the ear tumors of the control group (P < 0.05). Conclusion: ImmunoRFA led to improved survival and suppression of distant untreated tumor growth. Decreases in size of the distant untreated tumors and reimplanted tumors suggested that systemic antitumor immunity was enhanced by immunoRFA.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silva, E.R.C. da; Filho, B.J.C.
This paper presents a PWM current clamping circuit for improving a series resonant DC link converter. This circuit is capable of reducing current peaks to about 1.2--1.4 times the DC bias current. When desired, resonant transition creates notches in the dc link current, allowing the converter`s switches to synchronize with external PWM strategy. A regulated DC current source may be obtained--by using a conventional rectifier source--to feed a DC load or a current source inverter. Phase plane approach makes ease the understanding the operation, control and design procedure of the circuit. Another topology is derived and its features compared tomore » the first circuit. Simulation results for the simplified circuit and for a three-phase induction motor driven by such inverter will be presented. Moreover, the principle is corroborated by experimental results.« less
Research on Three-phase Four-wire Inverter
NASA Astrophysics Data System (ADS)
Xin, W. D.; Li, X. K.; Huang, G. Z.; Fan, X. C.; Gong, X. J.; Sun, L.; Wang, J.; Zhu, D. W.
2017-05-01
The concept of Voltage Source Converter (VSC) based hybrid AC and DC distribution system architecture is proposed, which can solve the traditional AC distribution power quality problems and respond to the request of DC distribution development. At first, a novel VSC system structure combining the four-leg based three-phase four-wire with LC filter is adopted, using the overall coordination control scheme of the AC current tracking compensation based grid-interfaced VSC. In the end, the 75 kW simulation experimental system is designed and tested to verify the performance of the proposed VSC under DC distribution, distributed DC sources conditions, as well as power quality management of AC distribution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oku, Takeo, E-mail: oku@mat.usp.ac.jp; Matsumoto, Taisuke; Ohishi, Yuya
A power storage system using spherical silicon (Si) solar cells, maximum power point tracking charge controller, lithium-ion battery and a direct current-alternating current (DC-AC) inverter was constructed. Performance evaluation of the DC-AC inverter was carried out, and the DC-AC conversion efficiencies of the SiC field-effect transistor (FET) inverter was improved compared with those of the ordinary Si-FET based inverter.
Increased Energy Delivery for Parallel Battery Packs with No Regulated Bus
NASA Astrophysics Data System (ADS)
Hsu, Chung-Ti
In this dissertation, a new approach to paralleling different battery types is presented. A method for controlling charging/discharging of different battery packs by using low-cost bi-directional switches instead of DC-DC converters is proposed. The proposed system architecture, algorithms, and control techniques allow batteries with different chemistry, voltage, and SOC to be properly charged and discharged in parallel without causing safety problems. The physical design and cost for the energy management system is substantially reduced. Additionally, specific types of failures in the maximum power point tracking (MPPT) in a photovoltaic (PV) system when tracking only the load current of a DC-DC converter are analyzed. The periodic nonlinear load current will lead MPPT realized by the conventional perturb and observe (P&O) algorithm to be problematic. A modified MPPT algorithm is proposed and it still only requires typically measured signals, yet is suitable for both linear and periodic nonlinear loads. Moreover, for a modular DC-DC converter using several converters in parallel, the input power from PV panels is processed and distributed at the module level. Methods for properly implementing distributed MPPT are studied. A new approach to efficient MPPT under partial shading conditions is presented. The power stage architecture achieves fast input current change rate by combining a current-adjustable converter with a few converters operating at a constant current.
Velasquez, Lis Noelia; Stüve, Philipp; Gentilini, Maria Virginia; Swallow, Maxine; Bartel, Judith; Lycke, Nils Yngve; Barkan, Daniel; Martina, Mariana; Lujan, Hugo D.; Kalay, Hakan; van Kooyk, Yvette; Sparwasser, Tim D.; Berod, Luciana
2018-01-01
Tuberculosis remains a major global health problem and efforts to develop a more effective vaccine have been unsuccessful so far. Targeting antigens (Ags) to dendritic cells (DCs) in vivo has emerged as a new promising vaccine strategy. In this approach, Ags are delivered directly to DCs via antibodies that bind to endocytic cell-surface receptors. Here, we explored DC-specific-ICAM3-grabbing-nonintegrin (DC-SIGN) targeting as a potential vaccine against tuberculosis. For this, we made use of the hSIGN mouse model that expresses human DC-SIGN under the control of the murine CD11c promoter. We show that in vitro and in vivo delivery of anti-DC-SIGN antibodies conjugated to Ag85B and peptide 25 of Ag85B in combination with anti-CD40, the fungal cell wall component zymosan, and the cholera toxin-derived fusion protein CTA1-DD induces strong Ag-specific CD4+ T-cell responses. Improved anti-mycobacterial immunity was accompanied by increased frequencies of Ag-specific IFN-γ+ IL-2+ TNF-α+ polyfunctional CD4+ T cells in vaccinated mice compared with controls. Taken together, in this study we provide the proof of concept that the human DC-SIGN receptor can be efficiently exploited for vaccine purposes to promote immunity against mycobacterial infections. PMID:29662482
DC water plasma at atmospheric pressure for the treatment of aqueous phenol.
Yuan, Min-Hao; Narengerile; Watanabe, Takayuki; Chang, Ching-Yuan
2010-06-15
This study investigated the decomposition of aqueous phenol by direct current (DC) water plasma. The operation of DC water plasma was carried out in the absence of inert gases or air injected and cooling-controlled and pressure-controlled devices. The results indicated that 1 mol.% (52.8 g L(-1)) phenol was drastically decomposed by DC water plasma touch with energy efficiencies of 1.9 x 10(-8)-2.2 x 10(-8) mol J(-1). Also, the value of chemical oxygen demand (COD) was reduced from 100 000 mg L(-1) down to 320 mg L(-1) over a short retention time. The maximum decomposition rate of the COD was 258 mg COD min(-1) for the arc power of 0.91 kW. In the effluent analysis, H(2) (63-68%), CO (3.6-6.3%), CO(2) (25.3-28.1%) were major products in the exhaust gas and CH(4), C(2)H(2), HCOOH and C(6)H(6) in trace level. Further, HCOOH and HCHO were observed in the liquid effluents. Within the current paper, the results indicated that the DC water plasma torch is capable of an alternative green technology for phenol wastewater containing high COD.
Submassive hepatic necrosis induced by dichloropropanol.
Haratake, J; Furuta, A; Iwasa, T; Wakasugi, C; Imazu, K
1993-06-01
A hitherto undescribed industrial liver injury of fulminant form induced by dichloropropanol is reported. Two middle-aged men developed severe hepatic injury just after cleaning a dichloropropanol tank at a plant producing dichloropropanol. They died from hepatic failure 4 and 11 days respectively, after carrying out the work. Liver specimens taken at autopsy from one of the cases showed submassive hepatic necrosis. This accident prompted us to undertake an experimental study in rats of intraperitoneal one-shot injection of two isomeric substances of dichloropropanol, that is, 2,3-dichloro-1-propanol (DC1P) and 1,3-dichloro-2-propanol (DC2P). Saline was injected into the control rats. One, two, four, six, 24, 48, 72 h, and 1 week after the injection, rats in each group were sacrificed. Neither control nor DC1P-injected rats showed significant biochemical or histopathological abnormalities. DC2P-injected rats revealed elevations of transaminase from 6 h after the injections, and submassive necrosis of the liver was observed in many rats. It was concluded that the severe liver injuries in both the human cases and rats in our study were caused by DC2P.
Controlled growth of aligned carbon nanotube using pulsed glow barrier discharge
NASA Astrophysics Data System (ADS)
Nozaki, Tomohiro; Kimura, Yoshihito; Okazaki, Ken
2002-10-01
We first achieved a catalytic growth of aligned carbon nanotube (CNT) using atmospheric pressure pulsed glow barrier discharge combined with DC bias (1000 V). Aligned CNT can grow with the directional electric field, and this is a big challenge in barrier discharges since dielectric barrier does not allow DC bias and forces to use AC voltage to maintain stable plasma conditions. To overcome this, we developed a power source generating Gaussian-shape pulses at 20 kpps with 4% duty, and DC bias was applied to the GND electrode where Ni-, Fe-coated substrate existed. With positive pulse, i.e. substrate was the cathode, random growth of CNT was observed at about 10^9 cm-2. Growth rate significantly reduced when applied negative pulse; Negative glow formation near substrate is essential for sufficient supply of radical species to the catalyst. If -DC was biased, aligned CNT with 20 nm was synthesized because negative bias enhanced negative glow formation. Interestingly, 2 to 3 CNTs stuck each other with +DC bias, resulting in 50-70 nm and non-aligned CNT. Atmospheric pressure glow barrier discharges can be highly controlled and be a potential alternative to vacuum plasmas for CVD, micro-scale, nano-scale fabrication.
Yilmaz, Atilla; Dietel, Barbara; Cicha, Iwona; Schubert, Katja; Hausmann, Roland; Daniel, Werner G; Garlichs, Christoph D; Stumpf, Christian
2010-03-01
Dendritic cells (DC) are crucial for T cell mediated immune responses. Recently, we observed a significant decrease in circulating myeloid DC precursors in patients with acute myocardial infarction (AMI). The aim of the present study was to investigate whether myeloid DC are present in infarcted myocardium. Myocardial specimens of 10 patients with AMI and 7 accident victims (controls) were collected after autopsy. In immunostainings the presence of DC (CD209(+), fascin(+)), T cells (CD3(+)), macrophages (CD68(+)), and HLA-DR expression was analyzed. Significantly higher numbers of CD209(+)-DC (97 vs. 44 cells/0.25 mm(2), p=0.03), fascin(+)-DC (54 vs. 8 cells/0.25 mm(2), p=0.02), T cells (27 vs. 6 cells/0.25 mm(2), p=0.02), and macrophages (44 vs. 6 cells/0.25 mm(2), p=0.01) associated with high HLA-DR expression were detected in infarcted myocardium. Frequent colocalizations of DC and T cells were observed. In occluded coronary arteries numerous DC, T cells, macrophages and high HLA-DR expression were found. We show that DC are present in infarcted myocardium after AMI. High HLA-DR expression and the colocalization with T cells suggest that they might trigger an immune response leading to further myocardial damage.
Controller for a High-Power, Brushless dc Motor
NASA Technical Reports Server (NTRS)
Fleming, David J.; Makdad, Terence A.
1987-01-01
Driving and braking torques controllable. Control circuit operates 7-kW, 45-lb-ft (61-N-m), three-phase, brushless dc motor in both motor and generator modes. In motor modes, energy from power source is pulse-width modulated to motor through modified "H-bridge" circuit, in generator mode, energy from motor is pulse-width modulated into bank of load resistors to provide variable braking torques. Circuit provides high-resolution torque control in both directions over wide range of speeds and torques. Tested successfully at bus voltages up to 200 Vdc and currents up to 45 A.
Cui, Yaya; Chatterjee, Asita; Yang, Hailian; Chatterjee, Arun K
2008-07-01
Erwinia carotovora subsp. carotovora produces an array of extracellular proteins (i.e., exoproteins), including plant cell wall-degrading enzymes and Harpin, an effector responsible for eliciting hypersensitive reaction. Exoprotein genes are coregulated by the quorum-sensing signal, N-acyl homoserine lactone, plant signals, an assortment of transcriptional factors/regulators (GacS/A, ExpR1, ExpR2, KdgR, RpoS, HexA, and RsmC) and posttranscriptional regulators (RsmA, rsmB RNA). rsmB RNA production is positively regulated by GacS/A, a two-component system, and negatively regulated by HexA (PecT in Erwinia chrysanthemi; LrhA [LysR homolog A] in Escherichia coli) and RsmC, a putative transcriptional adaptor. While free RsmA, an RNA-binding protein, promotes decay of mRNAs of exoprotein genes, binding of RsmA with rsmB RNA neutralizes the RsmA effect. In the course of studies of GacA regulation, we discovered that a locus bearing strong homology to the flhDC operon of E. coli also controls extracellular enzyme production. A transposon insertion FlhDC(-) mutant produces very low levels of pectate lyase, polygalacturonase, cellulase, protease, and E. carotovora subsp. carotovora Harpin (Harpin(Ecc)) and is severely attenuated in its plant virulence. The production of these exoproteins is restored in the mutant carrying an FlhDC(+) plasmid. Sequence analysis and transcript assays disclosed that the flhD operon of E. carotovora subsp. carotovora, like those of other enterobacteria, consists of flhD and flhC. Complementation analysis revealed that the regulatory effect requires functions of both flhD and flhC products. The data presented here show that FlhDC positively regulates gacA, rsmC, and fliA and negatively regulates hexA (lrhA). Evidence shows that FlhDC controls extracellular protein production through cumulative effects on hexA and gacA. Reduced levels of GacA and elevated levels of HexA in the FlhDC(-) mutant are responsible for the inhibition of rsmB RNA production, a condition conducive to the accumulation of free RsmA. Indeed, studies with an RsmA(-) FlhDC(-) double mutant and multiple copies of rsmB(+) DNA establish that the negative effect of FlhDC deficiency is exerted via RsmA. The FlhDC-mediated regulation of fliA has no bearing on exoprotein production in E. carotovora subsp. carotovora. Our observations for the first time establish a regulatory connection between FlhDC, HexA, GacA, and rsmB RNA in the context of the exoprotein production and virulence of E. carotovora subsp. carotovora.
Overproduction of cardiac S-adenosylmethionine decarboxylase in transgenic mice
Nisenberg, Oleg; Pegg, Anthony E.; Welsh, Patricia A.; Keefer, Kerry; Shantz, Lisa M.
2005-01-01
The present study was designed to provide a better understanding of the role played by AdoMetDC (S-adenosylmethionine decarboxylase), the key rate-controlling enzyme in the synthesis of spermidine and spermine, in controlling polyamine levels and the importance of polyamines in cardiac physiology. The αMHC (α-myosin heavy chain) promoter was used to generate transgenic mice with cardiac-specific expression of AdoMetDC. A founder line (αMHC/AdoMetDC) was established with a >100-fold increase in AdoMetDC activity in the heart. Transgene expression was maximal by 1 week of age and remained constant into adulthood. However, the changes in polyamine levels were most pronounced during the first week of age, with a 2-fold decrease in putrescine and spermidine and a 2-fold increase in spermine. At later times, spermine returned to near control levels, whereas putrescine and spermidine levels remained lower, suggesting that compensatory mechanisms exist to limit spermine accumulation. The αMHC/AdoMetDC mice did not display an overt cardiac phenotype, but there was an increased cardiac hypertrophy after β-adrenergic stimulation with isoprenaline (‘isoproterenol’), as well as a small increase in spermine content. Crosses of the αMHC/AdoMetDC with αMHC/ornithine decarboxylase mice that have a >1000-fold increase in cardiac ornithine decarboxylase were lethal in utero, presumably due to increase in spermine to toxic levels. These findings suggest that cardiac spermine levels are highly regulated to avoid polyamine-induced toxicity and that homoeostatic mechanisms can maintain non-toxic levels even when one enzyme of the biosynthetic pathway is greatly elevated but are unable to do so when two biosynthetic enzymes are increased. PMID:16153183
The management of colonic trauma in the damage control era
Shazi, B; Bruce, JL; Laing, GL; Sartorius, B
2017-01-01
INTRODUCTION The purpose of this study was to audit our current management of colonic trauma, and to review our experience of colonic trauma in patients who underwent initial damage control (DC) surgery. METHODS All patients treated for colonic trauma between January 2012 and December 2014 by the Pietermaritzburg Metropolitan Trauma Service were included in the study. Data reviewed included mechanism of injury, method of management (primary repair [PR], primary diversion [PD] or DC) and outcome (complications and mortality rate). Results A total of 128 patients sustained a colonic injury during the study period. Ninety-seven per cent of the injuries were due to penetrating trauma. Of these cases, 56% comprised stab wounds (SWs) and 44% were gunshot wounds (GSWs). Management was by PR in 99, PD in 20 and DC surgery in 9 cases. Among the 69 SW victims, 57 underwent PR, 9 had PD and 3 required a DC procedure. Of the 55 GSW cases, 40 were managed with PR, 9 with PD and 6 with DC surgery. In the PR group, there were 16 colonic complications (5 cases of breakdown and 11 of wound sepsis). Overall, nine patients (7%) died. CONCLUSIONS PR of colonic trauma is safe and should be used for the majority of such injuries. Persistent acidosis, however, should be considered a contraindication. In unstable patients with complex injuries, the optimal approach is to perform DC surgery. In this situation, formal diversion is contraindicated, and the injury should be controlled and dropped back into the abdomen at the primary operation. At the repeat operation, if the physiological insult has been reversed, then formal repair of the colonic injury is acceptable. PMID:27659359
The management of colonic trauma in the damage control era.
Shazi, B; Bruce, J L; Laing, G L; Sartorius, B; Clarke, D L
2017-01-01
INTRODUCTION The purpose of this study was to audit our current management of colonic trauma, and to review our experience of colonic trauma in patients who underwent initial damage control (DC) surgery. METHODS All patients treated for colonic trauma between January 2012 and December 2014 by the Pietermaritzburg Metropolitan Trauma Service were included in the study. Data reviewed included mechanism of injury, method of management (primary repair [PR], primary diversion [PD] or DC) and outcome (complications and mortality rate). Results A total of 128 patients sustained a colonic injury during the study period. Ninety-seven per cent of the injuries were due to penetrating trauma. Of these cases, 56% comprised stab wounds (SWs) and 44% were gunshot wounds (GSWs). Management was by PR in 99, PD in 20 and DC surgery in 9 cases. Among the 69 SW victims, 57 underwent PR, 9 had PD and 3 required a DC procedure. Of the 55 GSW cases, 40 were managed with PR, 9 with PD and 6 with DC surgery. In the PR group, there were 16 colonic complications (5 cases of breakdown and 11 of wound sepsis). Overall, nine patients (7%) died. CONCLUSIONS PR of colonic trauma is safe and should be used for the majority of such injuries. Persistent acidosis, however, should be considered a contraindication. In unstable patients with complex injuries, the optimal approach is to perform DC surgery. In this situation, formal diversion is contraindicated, and the injury should be controlled and dropped back into the abdomen at the primary operation. At the repeat operation, if the physiological insult has been reversed, then formal repair of the colonic injury is acceptable.
Backonja, Uba; Robledo, Candace A.; Wallace, Maeve E.; Flores, Katrina F.; Kiely, Michele
2016-01-01
Background Washington, D.C. has among the highest rates of sexually transmitted infections (STIs) and unintended pregnancy in the United States. Increasing women’s reproductive health knowledge may help address these reproductive health issues. This analysis assessed whether high-risk pregnant African American women in Washington, D.C. who participated in an intervention to reduce behavioral and psychosocial risks had greater reproductive health knowledge than women receiving usual care. Methods Project DC-HOPE was a randomized controlled trial that included pregnant African American women in Washington, D.C., recruited during prenatal care. Women in the intervention group were provided reproductive health education and received tailored counseling sessions to address their psychosocial and behavioral risk(s) (cigarette smoking, environmental tobacco smoke exposure, depression, and intimate partner violence). Women in the control group received usual prenatal care. Participants completed a 10-item reproductive knowledge assessment at baseline (n=1,044) and postpartum (n=830). Differences in total reproductive health knowledge scores at baseline and postpartum between groups were examined via chi-squared tests. Differences in postpartum mean total score by group were assessed via multiple linear regression. Results Women in both groups and at both time points scored approximately 50% on the knowledge assessments. At postpartum, women in the intervention group had higher total scores compared to women receiving usual care (mean 5.40 [SD 1.60] vs. 5.03 [SD 1.53] out of 10, respectively; p<0.001). Conclusions While intervention participants increased reproductive health knowledge, overall scores remained low. Development of interventions designed to impart accurate, individually tailored information to women may promote reproductive health knowledge among high-risk pregnant African American women residing in Washington, D.C. PMID:27094910
Nicolette, C A; Healey, D; Tcherepanova, I; Whelton, P; Monesmith, T; Coombs, L; Finke, L H; Whiteside, T; Miesowicz, F
2007-09-27
Dendritic cell (DC) active immunotherapy is potentially efficacious in a broad array of malignant disease settings. However, challenges remain in optimizing DC-based therapy for maximum clinical efficacy within manufacturing processes that permit quality control and scale-up of consistent products. In this review we discuss the critical issues that must be addressed in order to optimize DC-based product design and manufacture, and highlight the DC based platforms currently addressing these issues. Variables in DC-based product design include the type of antigenic payload used, DC maturation steps and activation processes, and functional assays. Issues to consider in development include: (a) minimizing the invasiveness of patient biological material collection; (b) minimizing handling and manipulations of tissue at the clinical site; (c) centralized product manufacturing and standardized processing and capacity for commercial-scale production; (d) rapid product release turnaround time; (e) the ability to manufacture sufficient product from limited starting material; and (f) standardized release criteria for DC phenotype and function. Improvements in the design and manufacture of DC products have resulted in a handful of promising leads currently in clinical development.
Activity of Electrical Current in Experimental Propionibacterium acnes Foreign-Body Osteomyelitis.
Schmidt-Malan, Suzannah M; Brinkman, Cassandra L; Greenwood-Quaintance, Kerryl E; Karau, Melissa J; Mandrekar, Jayawant N; Patel, Robin
2017-02-01
Foreign-body-associated infections are often difficult to treat, given that the associated microorganisms are in a biofilm state. Previously, we showed that a low-amperage direct electrical current (DC) reduces Propionibacterium acnes biofilms formed on implant-associated materials in vitro In this study, low-amperage DC was compared to ceftriaxone treatment or no treatment in a novel rat femur model of foreign-body osteomyelitis. A platinum implant seeded with a P. acnes biofilm (10 7 CFU/cm 2 ) and 10 9 CFU of planktonic P. acnes was placed in the femoral medullary cavity. One week later, rats were assigned to one of three treatment groups: no treatment, ceftriaxone treatment, or 200-μA-DC treatment. After 2 weeks of treatment, there were fewer bacteria in the bones of the ceftriaxone group (3.06 log 10 CFU/g of bone [P = 0.0209]) and the 200-μA-DC group (0.5 log 10 CFU/g [P = 0.0015]) than in those of the control group (6.58 log 10 CFU/g). The DC-exposed animals exhibited fewer bacteria than the ceftriaxone-treated animals (P = 0.0330). There were fewer bacteria on the implanted wires in the groups treated with ceftriaxone (0.1 log 10 CFU/cm 2 ) or a 200-μA DC (0.1 log 10 CFU/cm 2 ) than in the control group (2.53 log 10 CFU/cm 2 [P, 0.0003 for both comparisons]). Low-amperage DC may be useful for treating, or aiding in the treatment of, foreign-body infections caused by P. acnes. Copyright © 2017 American Society for Microbiology.
Thomas, S; Przesdzing, I; Metzke, D; Schmitz, J; Radbruch, A; Baumgart, D C
2009-01-01
Saccharomyces boulardii (Sb) is a probiotic yeast preparation that has demonstrated efficacy in inflammatory and infectious disorders of the gastrointestinal tract in controlled clinical trials. Although patients clearly benefit from treatment with Sb, little is known on how Sb unfolds its anti-inflammatory properties in humans. Dendritic cells (DC) balance tolerance and immunity and are involved critically in the control of T cell activation. Thus, they are believed to have a pivotal role in the initiation and perpetuation of chronic inflammatory disorders, not only in the gut. We therefore decided to investigate if Sb modulates DC function. Culture of primary (native, non-monocyte-derived) human myeloid CD1c+CD11c+CD123– DC (mDC) in the presence of Sb culture supernatant (active component molecular weight < 3 kDa, as evaluated by membrane partition chromatography) reduced significantly expression of the co-stimulatory molecules CD40 and CD80 (P < 0·01) and the DC mobilization marker CC-chemokine receptor CCR7 (CD197) (P < 0·001) induced by the prototypical microbial antigen lipopolysaccharide (LPS). Moreover, secretion of key proinflammatory cytokines such as tumour necrosis factor-α and interleukin (IL)-6 were notably reduced, while the secretion of anti-inflammatory IL-10 increased. Finally, Sb supernatant inhibited the proliferation of naive T cells in a mixed lymphocyte reaction with mDC. In summary, our data suggest that Sb may exhibit part of its anti-inflammatory potential through modulation of DC phenotype, function and migration by inhibition of their immune response to bacterial microbial surrogate antigens such as LPS. PMID:19161443
Zhao, Jing-Jing; Lou, Xiao-Li; Chen, Hong-Wei; Zhu, Feng-Ting; Hou, Yan-Qiang
2018-01-01
The levels of decoy receptor 3 (DcR3), soluble urokinase type plasminogen activator receptor (suPAR) and procalcitonin (PCT) are significantly increased in sepsis. We investigated the diagnostic value of DcR3 combined with suPAR and PCT in sepsis. Patients with sepsis, non-infectious systemic inflammatory response comprehensive syndrome (SIRS) and healthy controls were recruited according to the diagnostic standard. We measured DcR3, suPAR, PCT, interleukin-6 (IL-6) and C-reactive protein (CRP), and the diagnostic value was evaluated by receiver operating characteristics (ROC) curves. In our analysis, serum DcR3, suPAR and PCT levels of the sepsis group were significantly higher than those of the SIRS and control groups. However, IL-6, CRP and WBC showed no significant difference between the SIRS group and the sepsis group. The serum DcR3 level was positively correlated with the serum suPAR level ( r = 0.37, p = 0.0022) and PCT level ( r = 0.37, p = 0.0021). Using DcR3, suPAR and PCT to distinguish SIRS from sepsis, the area under the curve (AUC) values were 0.892, 0.778 and 0.692. When DcR3, suPAR and PCT combined were used for diagnosis of sepsis, the AUC was 0.933, at a cut-off point of 0.342. This combination improved the sensitivity and specificity of diagnosis of sepsis, suggesting that use of the combination of three indexes enhanced the efficiency of sepsis diagnosis.
Decentralized DC Microgrid Monitoring and Optimization via Primary Control Perturbations
NASA Astrophysics Data System (ADS)
Angjelichinoski, Marko; Scaglione, Anna; Popovski, Petar; Stefanovic, Cedomir
2018-06-01
We treat the emerging power systems with direct current (DC) MicroGrids, characterized with high penetration of power electronic converters. We rely on the power electronics to propose a decentralized solution for autonomous learning of and adaptation to the operating conditions of the DC Mirogrids; the goal is to eliminate the need to rely on an external communication system for such purpose. The solution works within the primary droop control loops and uses only local bus voltage measurements. Each controller is able to estimate (i) the generation capacities of power sources, (ii) the load demands, and (iii) the conductances of the distribution lines. To define a well-conditioned estimation problem, we employ decentralized strategy where the primary droop controllers temporarily switch between operating points in a coordinated manner, following amplitude-modulated training sequences. We study the use of the estimator in a decentralized solution of the Optimal Economic Dispatch problem. The evaluations confirm the usefulness of the proposed solution for autonomous MicroGrid operation.
Leleux, Jardin; Atalis, Alexandra; Roy, Krishnendu
2017-01-01
While successful vaccines have been developed against many pathogens, there are still many diseases and pathogenic infections that are highly evasive to current vaccination strategies. Thus, more sophisticated approaches to control the type and quality of vaccine-induced immune response must be developed. Dendritic cells (DCs) are the sentinels of the body and play a critical role in immune response generation and direction by bridging innate and adaptive immunity. It is now well recognized that DCs can be separated into many subgroups, each of which has a unique function. Better understanding of how various DC subsets, in lymphoid organs and in the periphery, can be targeted through controlled delivery; and how these subsets modulate and control the resulting immune response could greatly enhance our ability to develop new, effective vaccines against complex diseases. In this review, we provide an overview of DC subset biology and discuss current immunotherapeutic strategies that utilize DC targeting to modulate and control immune responses. PMID:26489733
Singh, Meenakshi; Parvez, Boriana; Banquet, Agnes; Kase, Jordan S
2018-02-20
To investigate whether Post-Acute Care Inpatient Rehabilitation (PACIR) admission after NICU stay affects the total length of stay (LOS) of very preterm (VPT: ≤30 weeks of gestation) infants. A retrospective case control study of VPT infants d/c'd from the NICU at Maria Fareri Children's Hospital (MFCH) to either a PACIR (Blythedale Children's Hospital: BH) for convalescent care (cases) or directly home (controls). 35 cases and 70 controls. Total LOS (MFCH + BH) was longer for cases [196 vs. 97 days]. At the time of d/c from MFCH, Special Health Care Needs (SHCN) amongst cases were greater than controls, however, became similar at the time of home d/c. The majority of cases achieved habilitation goals at the PACIR. Although LOS was longer for patients transferred to a PACIR, habilitation at BH Hospital reduced the SHCN at the time of home d/c amongst cases.
Pulse width modulation inverter with battery charger
Slicker, James M.
1985-01-01
An inverter is connected between a source of DC power and a three-phase AC induction motor, and a microprocessor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .theta., where .theta. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands for electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a "flyback" DC-DC converter circuit for recharging the battery.
Islam, Tariqul; Rahman, Ajijur; Islam, Anwar Ul
2012-01-01
To get better control in disease conditions, many people take herbs with conventional medicines, therefore, posing a risk of potential pharmacokinetic interactions between herbs and conventional drugs. The aqueous extract of the fresh leaves of Abroma augusta L. (Family: Sterculiaceae, Bengali name: Ulatkambal, English name: Devil's cotton, DC) is viscous and used traditionally to treat diabetes mellitus. This study was done to investigate the probable mechanism by which the aqueous extract of Abroma augusta L. is beneficial in managing type 2 DM and to observe the effects of this extract on absorption of metformin hydrochloride from the gastrointestinal tract. Studies were conducted in healthy Long Evans rats using Na-carboxymethyl cellulose (CMC) as positive control. Both Na-CMC and WSF of DC significantly (P < 0.05) reduced the absorption of glucose administered orally in fasted rats. On the other hand, WSF of DC significantly (P < 0.05) reduced the absorption of metformin hydrochloride in alloxan-induced diabetic rats. The results of this study suggest that WSF of DC may be beneficial in diabetic patients to improve glycemic control but should not be coadministered with metformin HCl for management of type 2 diabetes mellitus.
Pulse width modulation inverter with battery charger
NASA Technical Reports Server (NTRS)
Slicker, James M. (Inventor)
1985-01-01
An inverter is connected between a source of DC power and a three-phase AC induction motor, and a microprocessor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .theta., where .theta. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands for electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a flyback DC-DC converter circuit for recharging the battery.
75 FR 446 - In the Matter of Certain DC-DC Controllers and Products; Notice of Investigation
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
...,190; 6,414,470; and 7,132,717; and by reason of trade secret misappropriation. The complaint further... containing the same by reason of misappropriation of trade secrets, the threat or effect of which is to...
75 FR 15668 - Information Collection Activity; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-30
...., STOP 1522, Room 5159, South Building, Washington, DC 20250-1522. Telephone: (202) 690-1078. Fax: (202...., Washington, DC 20250-1522. Fax: (202) 720-8435. Title: Broadband Grant Program. OMB Control Number: 0572-0127...'' basis. The ``community-oriented connectivity'' concept integrates the deployment of broadband...
Felix, Kumar
2012-01-01
After stimulation of antigen-specific T cells, dendritic cell (DCs) are susceptible to killing by these activated T cells that involve perforin and Fas-dependent mechanisms. Fas-dependent DC apoptosis has been shown to limit DC accumulation and prevent the development of autoimmunity. However, a role for perforin in the maintenance of DC homeostasis for immune regulation remains to be determined. Here we show that perforin deficiency in mice, together with the deletion of Fas in DCs (perforin−/−DC-Fas−/−), led to DC accumulation, uncontrolled T-cell activation, and IFN-γ production by CD8+ T cells, resulting in the development of lethal hemophagocytic lymphohistiocytosis. Consistently, adoptive transfer of Fas−/− DCs induced over-activation and IFN-γ production in perforin−/− CD8+ T cells. Neutralization of IFN-γ prevented the spreading of inflammatory responses to different cell types and protected the survival of perforin−/−DC-Fas−/− mice. Our data suggest that perforin and Fas synergize in the maintenance of DC homeostasis to limit T cell activation, and prevent the initiation of an inflammatory cascade. PMID:22042696
Eicosanoids: an emerging role in dendritic cell biology.
Harizi, Hedi; Gualde, Norbert
2004-01-01
The arachidonic acid (AA)-derived metabolites, termed eicosanoids, are potent lipid mediators with a key role in immune and inflammatory responses. In the immune system, eicosanoids such as prostaglandins (PGs) and leukotrienes (LTs) are produced predominately by antigen-presenting cells (APC), including macrophages and dendritic cells (DC). DC constitute a family of bone marrow-derived professional APC that play a critical role in the induction and modulation of both innate and adaptive immunity. For many years, macrophages were considered as major producers of eicosanoids that are thought to drastically affect their function. Studies concerning the modulation of DC biology by eicosanoids show that PGs and LTs have the potential to affect the maturation, cytokine-producing capacity, Th cell-polarizing ability, and migration of DC. In addition, the development of DC from bone marrow progenitors appears to be under the control of some eicosanoids. Understanding the actions of eicosanoids and their receptors on APC functions is crucial for the generation of efficient DC for therapeutic purposes in patients. In this review, we summarize the current understanding of how DC functions are modulated by eicosanoids.
BFDCA: A Comprehensive Tool of Using Bayes Factor for Differential Co-Expression Analysis.
Wang, Duolin; Wang, Juexin; Jiang, Yuexu; Liang, Yanchun; Xu, Dong
2017-02-03
Comparing the gene-expression profiles between biological conditions is useful for understanding gene regulation underlying complex phenotypes. Along this line, analysis of differential co-expression (DC) has gained attention in the recent years, where genes under one condition have different co-expression patterns compared with another. We developed an R package Bayes Factor approach for Differential Co-expression Analysis (BFDCA) for DC analysis. BFDCA is unique in integrating various aspects of DC patterns (including Shift, Cross, and Re-wiring) into one uniform Bayes factor. We tested BFDCA using simulation data and experimental data. Simulation results indicate that BFDCA outperforms existing methods in accuracy and robustness of detecting DC pairs and DC modules. Results of using experimental data suggest that BFDCA can cluster disease-related genes into functional DC subunits and estimate the regulatory impact of disease-related genes well. BFDCA also achieves high accuracy in predicting case-control phenotypes by using significant DC gene pairs as markers. BFDCA is publicly available at http://dx.doi.org/10.17632/jdz4vtvnm3.1. Copyright © 2016 Elsevier Ltd. All rights reserved.
Microbiota induces tonic CCL2 systemic levels that control pDC trafficking in steady state.
Swiecki, M; Miller, H L; Sesti-Costa, R; Cella, M; Gilfillan, S; Colonna, M
2017-07-01
Plasmacytoid dendritic cells (pDCs) detect viruses initiating antiviral type I interferon responses. The microbiota is known to shape immune responses, but whether it influences pDC homeostasis and/or function is poorly understood. By comparing pDCs in germ-free and specific pathogen-free mice, we found that the microbiota supports homeostatic trafficking by eliciting constitutive levels of the chemokine CCL2 that engages CCR2. Mononuclear phagocytes were required for tonic CCL2 levels. CCL2 was particularly important for trafficking of a CCR2 hi subset of pDCs that produced proinflammatory cytokines and was prone to apoptosis. We further demonstrated that CCR2 was also essential for pDC migration during inflammation. Wild-type (WT):Ccr2 -/- mixed bone marrow chimeras revealed that CCR2 promotes pDC migration in a cell-intrinsic manner. Overall, we identify a novel role for the microbiota in shaping immunity, which includes induction of CCL2 levels that control homeostatic trafficking of pDCs.
High static gain single-phase PFC based on a hybrid boost converter
NASA Astrophysics Data System (ADS)
Flores Cortez, Daniel; Maccarini, Marcello C.; Mussa, Samir A.; Barbi, Ivo
2017-05-01
In this paper, a single-phase unity power factor rectifier, based on a hybrid boost converter, resulting from the integration of a conventional dc-dc boost converter and a switched-capacitor voltage doubler is proposed, analysed, designed and tested. The high-power rectifier is controlled by two feedback loops with the same control strategy employed in the conventional boost-based rectifier. The main feature of the proposed rectifier is its ability to output a dc voltage larger than the double of the peak value of the input line voltage, while subjecting the power switches to half of the dc-link voltage, which contributes to reducing the cost and increasing the efficiency. Experimental data were obtained from a laboratory prototype with an input voltage of 220 Vrms, line frequency of 60 Hz, output voltage of 800 Vdc, load power of 1000 W and switching frequency of 50 kHz. The efficiency of the prototype, measured in the laboratory, was 96.5% for full load and 97% for half load.
Modelling and Simulation of Grid Connected SPV System with Active Power Filtering Features
NASA Astrophysics Data System (ADS)
Saroha, Jaipal; Pandove, Gitanjali; Singh, Mukhtiar
2017-09-01
In this paper, the detailed simulation studies for a grid connected solar photovoltaic system (SPV) have been presented. The power electronics devices like DC-DC boost converter and grid interfacing inverter are most important components of proposed system. Here, the DC-DC boost converter is controlled to extract maximum power out of SPV under different irradiation levels, while the grid interfacing inverter is utilized to evacuate the active power and feed it into grid at synchronized voltage and frequency. Moreover, the grid interfacing inverter is also controlled to sort out the issues related to power quality by compensating the reactive power and harmonics current component of nearby load at point of common coupling. Besides, detailed modeling of various component utilized in proposed system is also presented. Finally, extensive simulations have been performed under different irradiation levels with various kinds of load to validate the aforementioned claims. The overall system design and simulation have been performed by using Sim Power System toolbox available in the library of MATLAB.
Indigenous enteric eosinophils control DCs to initiate a primary Th2 immune response in vivo
Chu, Derek K.; Jimenez-Saiz, Rodrigo; Verschoor, Christopher P.; Walker, Tina D.; Goncharova, Susanna; Llop-Guevara, Alba; Shen, Pamela; Gordon, Melissa E.; Barra, Nicole G.; Bassett, Jennifer D.; Kong, Joshua; Fattouh, Ramzi; McCoy, Kathy D.; Bowdish, Dawn M.; Erjefält, Jonas S.; Pabst, Oliver; Humbles, Alison A.; Kolbeck, Roland; Waserman, Susan
2014-01-01
Eosinophils natively inhabit the small intestine, but a functional role for them there has remained elusive. Here, we show that eosinophil-deficient mice were protected from induction of Th2-mediated peanut food allergy and anaphylaxis, and Th2 priming was restored by reconstitution with il4+/+ or il4−/− eosinophils. Eosinophils controlled CD103+ dendritic cell (DC) activation and migration from the intestine to draining lymph nodes, events necessary for Th2 priming. Eosinophil activation in vitro and in vivo led to degranulation of eosinophil peroxidase, a granule protein whose enzymatic activity promoted DC activation in mice and humans in vitro, and intestinal and extraintestinal mouse DC activation and mobilization to lymph nodes in vivo. Further, eosinophil peroxidase enhanced responses to ovalbumin seen after immunization. Thus, eosinophils can be critical contributors to the intestinal immune system, and granule-mediated shaping of DC responses can promote both intestinal and extraintestinal adaptive immunity. PMID:25071163
A New Supercapacitor and Li-ion Battery Hybrid System for Electric Vehicle in ADVISOR
NASA Astrophysics Data System (ADS)
Peng, Xiao; Shuhai, Quan; Changjun, Xie
2017-02-01
The supercapacitor (SC) and Li-ion battery(BT) hybrid energy storage system(HESS) electric vehicle(EV) is gaining universal attention. The topology is of importance for the SC/BT HESS. A new SC/BT topology HESS with a rule-based energy management strategy for EV was proposed. The BT pack is connected directly to the DC link via a controlled switch. The SC pack is connected to the DC link via a controlled switch. A uni-directional DC/DC converter is connected between the SC pack and the BT pack. The braking regeneration energy is all harvested by the SC pack. The output power of BT pack is limited. The different SC/BT configurations with varied BT maximum Ah capacity factor and SC maximum capacity factor are simulated in ADVISOR. Simulation results show that BT maximum Ah capacity factor has little impact on vehicle acceleration performance and maximum speed. SC maximum capacity factor has significant impact on vehicle acceleration performance and maximum speed. The fuel economy isn’t affected.
Salim, Nesreen; Satterthwaite, Julian; Rautemaa, Riina; Silikas, Nick
2012-01-01
This study investigated the impact of impregnation of a poly(ethyl methacrylate) /tetrahydrofurfuryl methacrylate (PEM/THFM) polymer with chlorhexidine or fluconazole on the degree of conversion (DC) and colour stability (ΔE). The DC of uncured (0 h) and cured (24 h) samples was analysed by Fourier transform infrared spectroscopy (FTIR) and colour stability was analysed colorimetrically. The DC percentage of the control samples was significantly greater than those containing chlorhexidine and fluconazole (p≤0.05). The control discs exhibited only slight colour change compared to the impregnated discs which showed marked colour change (p≤0.05). A strong negative correlation between the extent of colour change and the degree of conversion was detected (r=0.97). The DC and colour stability were influenced by the addition of chlorhexidine or fluconazole. However, the final values were comparable to other commonly used acrylic liners and within acceptable ranges. PEM/THFM can be considered as a biocompatible drug delivery system.
User's design handbook for a Standardized Control Module (SCM) for DC to DC Converters, volume 2
NASA Technical Reports Server (NTRS)
Lee, F. C.
1980-01-01
A unified design procedure is presented for selecting the key SCM control parameters for an arbitrarily given power stage configuration and parameter values, such that all regulator performance specifications can be met and optimized concurrently in a single design attempt. All key results and performance indices, for buck, boost, and buck/boost switching regulators which are relevant to SCM design considerations are included to facilitate frequent references.
Weight-Handling Equipment. Design Manual 38.1.
1982-06-01
Contact Rails ....... ................... 38.1-153 B-1. Torque-Speed Curves of Wound- Rotor Motor with Single-Phase Dynamic Braking Control...38.1-B-4 B-2. Torque-Speed Curves for Wound- Rotor Motor with DC Dynamic -Braking Lowering Control ... ........... . 38.1-B-6 B-3. Torque-Speed Curves...AC hoist and DC dynamic -braking lowering). (b) Wound- rotor motors. (i) Heavy-duty cranes using AC motors should have motors of the wound- rotor (slip
Actuator Characterization of Man Portable Precision Maneuver Concepts
2014-03-01
brushless DC motors, along with a model of the rotating wing concept and a prototype 40-mm projectile, which was fired through the spark range (14), is... Brushless Electronic Speed Controller) was used to drive the three motor commutator input lines. This controller inputs a pulse-width modulated (PWM...Part II: The Brushless D.C. Motor Drive. IEEE Transactions on Industry Applications 1989, 25 (2), 274–279. 16. Hemati, N.; Leu, M. A Complete
Increased resting-state brain entropy in Alzheimer's disease.
Xue, Shao-Wei; Guo, Yonghu
2018-03-07
Entropy analysis of resting-state functional MRI (R-fMRI) is a novel approach to characterize brain temporal dynamics and facilitates the identification of abnormal brain activity caused by several disease conditions. However, Alzheimer's disease (AD)-related brain entropy mapping based on R-fMRI has not been assessed. Here, we measured the sample entropy and voxel-wise connectivity of the network degree centrality (DC) of the intrinsic brain activity acquired by R-fMRI in 26 patients with AD and 26 healthy controls. Compared with the controls, AD patients showed increased entropy in the middle temporal gyrus and the precentral gyrus and also showed decreased DC in the precuneus. Moreover, the magnitude of the negative correlation between local brain activity (entropy) and network connectivity (DC) was increased in AD patients in comparison with healthy controls. These findings provide new evidence on AD-related brain entropy alterations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Yalong; Jones, Edward A.; Wang, Fred
Arm inductor in a modular multilevel converter (MMC) is used to limit the circulating current and dc short circuit fault current. The circulating current in MMC is dominated by second-order harmonic, which can be largely reduced with circulating current suppressing control. By analyzing the mechanism of the circulating current suppressing control, it is found that the circulating current at switching frequency becomes the main harmonic when suppression control is implemented. Unlike the second-order harmonic that circulates only within the three phases, switching frequency harmonic also flows through the dc side and may further cause high-frequency dc voltage harmonic. This articlemore » develops the theoretical relationship between the arm inductance and switching frequency circulating current, which can be used to guide the arm inductance selection. The experimental results with a downscaled MMC prototype verify the existence of the switching frequency circulating current and its relationship with arm inductance.« less
NASA Technical Reports Server (NTRS)
Edie, P. C.
1981-01-01
Performance data on the Prestolite MTC-4001 series wound dc motor and General Electric EV-1 Chopper Controller is supplied for the electric vehicle manufacturer. Data are provided for both straight and chopped dc input to the motor, at 2 motor temperature levels. Testing was done at 6 voltage increments to the motor, and 2 voltage increments to the controller. Data results are presented in both tabular and graphical forms. Tabular information includes motor voltage and current input data, motor speed and torque output data, power data and temperature data. Graphical information includes torque-speed, motor power output-speed, torque-current, and efficiency-speed plots under the various operating conditions. The data resulting from this testing show the speed-torque plots to have the most variance with operating temperature. The maximum motor efficiency is between 76% and 82%, regardless of temperature or mode of operation.
DC Bus Regulation with a Flywheel Energy Storage System
NASA Technical Reports Server (NTRS)
Kenny, Barbara H.; Kascak, Peter E.
2003-01-01
This paper describes the DC bus regulation control algorithm for the NASA flywheel energy storage system during charge, charge reduction and discharge modes of operation. The algorithm was experimentally verified with results given in a previous paper. This paper presents the necessary models for simulation with detailed block diagrams of the controller algorithm. It is shown that the flywheel system and the controller can be modeled in three levels of detail depending on the type of analysis required. The three models are explained and then compared using simulation results.
NASA Technical Reports Server (NTRS)
Rajagopalan, J.; Xing, K.; Guo, Y.; Lee, F. C.; Manners, Bruce
1996-01-01
A simple, application-oriented, transfer function model of paralleled converters employing Master-Slave Current-sharing (MSC) control is developed. Dynamically, the Master converter retains its original design characteristics; all the Slave converters are forced to depart significantly from their original design characteristics into current-controlled current sources. Five distinct loop gains to assess system stability and performance are identified and their physical significance is described. A design methodology for the current share compensator is presented. The effect of this current sharing scheme on 'system output impedance' is analyzed.
Decentralized control of the COFS-I Mast using linear dc motors
NASA Technical Reports Server (NTRS)
Lindner, Douglas K.; Celano, Tom; Ide, Eric
1989-01-01
Consideration is given to a decentralized control design for vibration suppression in the COFS-I Mast using linear dc motors for actuators. The decentralized control design is based results from power systems using root locus techniques that are not well known. The approach is effective because the loop gain is low due to low actuator authority. The frequency-dependent nonlinearities of the actuator are taken into account. Because of the tendency of the transients to saturate the the stroke length of the actuator, its effectiveness is limited.
Amorocho, Diego F; Abreu-Grobois, F Alberto; Dutton, Peter H; Reina, Richard D
2012-01-01
Mitochondrial DNA analyses have been useful for resolving maternal lineages and migratory behavior to foraging grounds (FG) in sea turtles. However, little is known about source rookeries and haplotype composition of foraging green turtle aggregations in the southeastern Pacific. We used mitochondrial DNA control region sequences to identify the haplotype composition of 55 green turtles, Chelonia mydas, captured in foraging grounds of Gorgona National Park in the Colombian Pacific. Amplified fragments of the control region (457 bp) revealed the presence of seven haplotypes, with haplotype (h) and nucleotide (π) diversities of h = 0.300±0.080 and π = 0.009±0.005 respectively. The most common haplotype was CMP4 observed in 83% of individuals, followed by CMP22 (5%). The genetic composition of the Gorgona foraging population primarily comprised haplotypes that have been found at eastern Pacific rookeries including Mexico and the Galapagos, as well as haplotypes of unknown stock origin that likely originated from more distant western Pacific rookeries. Mixed stock analysis suggests that the Gorgona FG population is comprised mostly of animals from the Galapagos rookery (80%). Lagrangian drifter data showed that movement of turtles along the eastern Pacific coast and eastward from distant western and central Pacific sites was possible through passive drift. Our results highlight the importance of this protected area for conservation management of green turtles recruited from distant sites along the eastern Pacific Ocean.
Amorocho, Diego F.; Abreu-Grobois, F. Alberto; Dutton, Peter H.; Reina, Richard D.
2012-01-01
Mitochondrial DNA analyses have been useful for resolving maternal lineages and migratory behavior to foraging grounds (FG) in sea turtles. However, little is known about source rookeries and haplotype composition of foraging green turtle aggregations in the southeastern Pacific. We used mitochondrial DNA control region sequences to identify the haplotype composition of 55 green turtles, Chelonia mydas, captured in foraging grounds of Gorgona National Park in the Colombian Pacific. Amplified fragments of the control region (457 bp) revealed the presence of seven haplotypes, with haplotype (h) and nucleotide (π) diversities of h = 0.300±0.080 and π = 0.009±0.005 respectively. The most common haplotype was CMP4 observed in 83% of individuals, followed by CMP22 (5%). The genetic composition of the Gorgona foraging population primarily comprised haplotypes that have been found at eastern Pacific rookeries including Mexico and the Galapagos, as well as haplotypes of unknown stock origin that likely originated from more distant western Pacific rookeries. Mixed stock analysis suggests that the Gorgona FG population is comprised mostly of animals from the Galapagos rookery (80%). Lagrangian drifter data showed that movement of turtles along the eastern Pacific coast and eastward from distant western and central Pacific sites was possible through passive drift. Our results highlight the importance of this protected area for conservation management of green turtles recruited from distant sites along the eastern Pacific Ocean. PMID:22319635
Power processing and control requirements of dispersed solar thermal electric generation systems
NASA Technical Reports Server (NTRS)
Das, R. L.
1980-01-01
Power Processing and Control requirements of Dispersed Receiver Solar Thermal Electric Generation Systems are presented. Kinematic Stirling Engines, Brayton Engines and Rankine Engines are considered as prime movers. Various types of generators are considered for ac and dc link generations. It is found that ac-ac Power Conversion is not suitable for implementation at this time. It is also found that ac-dc-ac Power Conversion with a large central inverter is more efficient than ac-dc-ac Power Conversion using small dispersed inverters. Ac-link solar thermal electric plants face potential stability and synchronization problems. Research and development efforts are needed in improving component performance characteristics and generation efficiency to make Solar Thermal Electric Generation economically attractive.
Tu, Juan; Ha Hwang, Joo; Chen, Tao; Fan, Tingbo; Guo, Xiasheng; Crum, Lawrence A.; Zhang, Dong
2012-01-01
High intensity focused ultrasound (HIFU)-induced hyperthermia is a promising tool for cancer therapy. Three-dimensional nonlinear acoustic-bioheat transfer-blood flow-coupling model simulations and in vivo thermocouple measurements were performed to study hyperthermia effects in rabbit auricular vein exposed to pulsed HIFU (pHIFU) at varied duty cycles (DCs). pHIFU-induced temperature elevations are shown to increase with increasing DC. A critical DC of 6.9% is estimated for temperature at distal vessel wall exceeding 44 °C, although different tissue depths and inclusions could affect the DC threshold. The results demonstrate clinic potentials of achieving controllable hyperthermia by adjusting pHIFU DCs, while minimizing perivascular thermal injury. PMID:23112347
The 30-cm ion thruster power processor
NASA Technical Reports Server (NTRS)
Herron, B. G.; Hopper, D. J.
1978-01-01
A power processor unit for powering and controlling the 30 cm Mercury Electron-Bombardment Ion Thruster was designed, fabricated, and tested. The unit uses a unique and highly efficient transistor bridge inverter power stage in its implementation. The system operated from a 200 to 400 V dc input power bus, provides 12 independently controllable and closely regulated dc power outputs, and has an overall power conditioning capacity of 3.5 kW. Protective circuitry was incorporated as an integral part of the design to assure failure-free operation during transient and steady-state load faults. The implemented unit demonstrated an electrical efficiency between 91.5 and 91.9 at its nominal rated load over the 200 to 400 V dc input bus range.
An SCR inverter for electric vehicles
NASA Technical Reports Server (NTRS)
Latos, T.; Bosack, D.; Ehrlich, R.; Jahns, T.; Mezera, J.; Thimmesch, D.
1980-01-01
An inverter for an electric vehicle propulsion application has been designed and constructed to excite a polyphase induction motor from a fixed propulsion battery source. The inverter, rated at 35kW peak power, is fully regenerative and permits vehicle operation in both the forward and reverse directions. Thyristors are employed as the power switching devices arranged in a dc bus commutated topology. This paper describes the major role the controller plays in generating the motor excitation voltage and frequency to deliver performance similar to dc systems. Motoring efficiency test data for the controller are presented. It is concluded that an SCR inverter in conjunction with an ac induction motor is a viable alternative to present dc vehicle propulsion systems on the basis of performance and size criteria.
A novel control strategy for enhancing the LVRT and voltage support capabilities of DFIG
NASA Astrophysics Data System (ADS)
Shen, Yangwu; Zhang, Bin; Liang, Liqing; Cui, Ting
2018-02-01
A novel integrated control strategy is proposed in this paper to enhance the low voltage ride through capacity for the double-fed induction generator by equipping an energy storage system. The energy storage system is installed into the DC-link capacitor of the DFIG and used to control the DC-link voltage during normal or transient operations. The energy storage device will absorb or compensate the power difference between the captured wind power and the power injected to the grid during the normal and transient period, and the grid side converter can be free from maintaining the voltage stability of the DC-link capacitor. Thus, the grid-side converter is changed to reactive power support while the rotor-side converter is used to control the maximum power production during normal operation. The grid-side converter and rotor-side converter will act as reactive power sources to further enhance the voltage support capability of double-fed induction generator during the transient period. Numerical Simulation are performed to validate the effectiveness of the proposed control designs.
Power-MOSFET Voltage Regulator
NASA Technical Reports Server (NTRS)
Miller, W. N.; Gray, O. E.
1982-01-01
Ninety-six parallel MOSFET devices with two-stage feedback circuit form a high-current dc voltage regulator that also acts as fully-on solid-state switch when fuel-cell out-put falls below regulated voltage. Ripple voltage is less than 20 mV, transient recovery time is less than 50 ms. Parallel MOSFET's act as high-current dc regulator and switch. Regulator can be used wherever large direct currents must be controlled. Can be applied to inverters, industrial furnaces photovoltaic solar generators, dc motors, and electric autos.
1986-11-01
START THE RUN>>> USERNUIDNUPW. CHARGEGROUPNPID. SETJOB, DC= NO . COMMENT . GET CR ATTACH THE INPUT DATA TO GO TO VSOS. GET, INDATA=DATFILE/NA. IFE...NtPW. CHARGEGROUPNPID. SETTL, 200. SETJOB. DC= NO . COMMENT . RUN SAIL ON NOS TO GENERATE THE MAIN PROGRAM. PURGE, SAl LOUT/NA. PURGE, PROG-PROBLEMID...NOSPASS. CHARGEDFCDFCPR.F. SETJOB. DC= NO . COMMENT . GET OR ATTACH THE INPUT DATA To Go To VSOS. GET. INDATA=MYDATA/NA. IFE. .NOT.FILE(INDATA.AS) .DOATT
Electrical safety for high voltage arrays
NASA Technical Reports Server (NTRS)
Marshall, N. A.
1983-01-01
A number of key electrical safety requirements for the high voltage arrays of central station photovoltaic power systems are explored. The suitability of representative industrial DC power switchgear for control and fault protection was evaluated. Included were AC/DC circuit breakers, electromechanical contactors and relays, load interruptors, cold disconnect devices, sectionalizing switches, and high voltage DC fuses. As appropriate, steady state and transient characteristics were analyzed. Failure modes impacting upon operation and maintenance safety were also identified, as were the voltage withstand and current interruption levels.
Mitchell, Ann M; Sakraida, Teresa J; Kim, Yookyung; Bullian, Leann; Chiappetta, Laurel
2009-02-01
The study's purpose was to describe and compare depression, anxiety, and quality of life, by degree of relationship, between closely related and distantly related survivors (persons close to the suicide victim, or "suicide survivors"; N = 60) during the acute phase of bereavement (within 1 month of the death). The close relationship category included spouses, parents, children, and siblings, whereas the distant relationship category included in-laws, aunts/uncles, and nieces/nephews. Analysis of covariance examined differences between the two groups on the symptom measures. Results indicate that, after controlling for age and gender effects, closely related survivors had significantly higher mean levels of depression and anxiety and had lower levels of mental health quality of life. There were no statistically significant differences on the physical health quality of life subscale.
Ge, Zhicheng; Sanders, Andrew J; Ye, Lin; Wang, Yu; Jiang, Wen G
2011-01-01
Death Decoy Receptor-3 (DcR3), otherwise known as tumour necrosis factor receptor superfamily member 6b, is suggested to be involved in the progression and immune evasion of malignant tumours. Its ligands include FASL and LIGHT (Tumour necrosis factor ligand superfamily member 14). DcR3 has been found to be amplified in certain solid tumours. However, its role in breast tumours remains unclear. In the present study, we examined the role played by DcR3 in MCF7 and MDA-MB-231 cell lines. The expression of DcR3 was examined in MCF7 and MDA-MB-231 cell lines using immunocytochemical staining and RT-PCR. Anti-DcR3 hammerhead ribozyme transgenes were constructed and transfected into cells to create DcR3 knock-down cell sublines. The biological impact of modifying DcR3 expression in breast cancer cells was evaluated using a variety of in vitro assays, including growth, adhesion, migration and invasion models. MCF7 and MDA-MB-231 cells, usually expressing DcR3, were transfected with the anti-DcR3 ribozyme transgene. Stable transfectants containing the DcR3 ribozyme transgene (MCF7DcR3KO, MDA-MB-231DcR3KO) displayed a reduction of DcR3 expression at mRNA and protein levels. DcR3 knockdown in MCF7 cells was found to significantly reduce invasive capacity compared to pEF6 control cell lines (30.78 +/- 6.40 vs.151.67 +/- 17.67 P < 0.001). The rate of migration in MCF7DcR3KO was significantly lower than MCF7pEF6 (P < 0.001). In contrast, no such significant differences was seen between MDA-MB-231DcR3KO and MDA-MB-231pEF6. Suppressing DcR3 expression was found to have an inhibitory effect on cellular invasion and migration in MCF7 breast cancer cells. This suggests that the invasion and migration capacity of this breast cancer cell line may, at least partly, depend on DcR3. DcR3 may be regarded as a negative regulator for aggressiveness during the development and progression of certain types of breast cancer.
Dendritic cells: key to fetal tolerance?
Blois, Sandra M; Kammerer, Ulrike; Alba Soto, Catalina; Tometten, Mareike C; Shaikly, Valerie; Barrientos, Gabriela; Jurd, Richard; Rukavina, Daniel; Thomson, Angus W; Klapp, Burghard F; Fernández, Nelson; Arck, Petra C
2007-10-01
Pregnancy is a unique event in which a fetus, despite being genetically and immunologically different from the mother (a hemi-allograft), develops in the uterus. Successful pregnancy implies avoidance of rejection by the maternal immune system. Fetal and maternal immune cells come into direct contact at the decidua, which is a highly specialized mucous membrane that plays a key role in fetal tolerance. Uterine dendritic cells (DC) within the decidua have been implicated in pregnancy maintenance. DC serve as antigen-presenting cells with the unique ability to induce primary immune responses. Just as lymphocytes comprise different subsets, DC subsets have been identified that differentially control lymphocyte function. DC may also act to induce immunologic tolerance and regulation of T cell-mediated immunity. Current understanding of DC immunobiology within the context of mammalian fetal-maternal tolerance is reviewed and discussed herein.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bagley, G. P.
An SCR DC to DC converter is described which will operate at an output of 275 kW and will supply current to electron storage ring magnets requiring 5 h stability of 50 ppM. The operation of this modified chopper is described and design equations are presented, along with the system control loop description.
An Integrated Programmable Wide-range PLL for Switching Synchronization in Isolated DC-DC Converters
NASA Astrophysics Data System (ADS)
Fard, Miad
In this thesis, two Phase-Locked-Loop (PLL) based synchronization schemes are introduced and applied to a bi-directional Dual-Active-Bridge (DAB) dc-dc converter with an input voltage up to 80 V switching in the range of 250 kHz to 1 MHz. The two schemes synchronize gating signals across an isolated boundary without the need for an isolator per transistor. The Power Transformer Sensing (PTS) method utilizes the DAB power transformer to indirectly sense switching on the secondary side of the boundary, while the Digital Isolator Sensing (DIS) method utilizes a miniature transformer for synchronization and communication at up to 100 MHz. The PLL is implemented on-chip, and is used to control an external DAB power-stage. This work will lead to lower cost, high-frequency isolated dc-dc converters needed for a wide variety of emerging low power applications where isolator cost is relatively high and there is a demand for the reduction of parts.
Light weight, high power, high voltage dc/dc converter technologies
NASA Technical Reports Server (NTRS)
Kraus, Robert; Myers, Ira; Baumann, Eric
1990-01-01
Power-conditioning weight reductions by orders of magnitude will be required to enable the megawatt-power-level space systems envisioned by the Strategic Defense Initiative, the Air Force, and NASA. An interagency program has been initiated to develop an 0.1-kg/kW dc/dc converter technology base for these future space applications. Three contractors are in the first phase of a competitive program to develop a megawatt dc/dc converter. Researchers at NASA Lewis Research Center are investigating innovative converter topology control. Three different converter subsystems based on square wave, resonant, and super-resonant topologies are being designed. The components required for the converter designs cover a wide array of technologies. Two different switches, one semiconductor and the other gas, are under development. Issues related to thermal management and material reliability for inductors, transformers, and capacitors are being investigated in order to maximize power density. A brief description of each of the concepts proposed to meet the goals of this program is presented.
A miniature transformer/dc-dc converter for implantable medical devices
NASA Astrophysics Data System (ADS)
Mohammed, Osama A.; Jones, W. Kinzy
1988-11-01
This paper presents a new technique for the design of a miniature dc-dc converter used in energy producing implantable devices such as defibrillators and advanced pacemakers. This converter is inserted in such a device and is used to boost the voltage from a low voltage implanted battery to high voltage energy storage capacitors in a short period of time. The stored energy is then delivered, when needed, through an energy delivery circuit in order to stimulate or defibrillate the heart. The converter takes the form of a flyback topology which includes a miniature transformer and a specialized control circuit. The transformer was designed using a new numerical synthesis method which utilizes finite elements and dynamic programming for predicting the geometries of the transformer's magnetic circuit. The final transformer design satisfied the performance criteria and provided means for selecting the converter components. The obtained performance results for the transformer and the dc-dc converter were in excellent agreement with laboratory performance tests.
Multi-megawatt inverter/converter technology for space power applications
NASA Technical Reports Server (NTRS)
Myers, Ira T.; Baumann, Eric D.; Kraus, Robert; Hammoud, Ahmad N.
1992-01-01
Large power conditioning mass reductions will be required to enable megawatt power systems envisioned by the Strategic Defense Initiative, the Air Force, and NASA. Phase 1 of a proposed two phase interagency program has been completed to develop an 0.1 kg/kW DC/DC converter technology base for these future space applications. Three contractors, Hughes, General Electric (GE), and Maxwell were Phase 1 contractors in a competitive program to develop a megawatt lightweight DC/DC converter. Researchers at NASA Lewis Research Center and the University of Wisconsin also investigated technology in topology and control. All three contractors, as well as the University of Wisconsin, concluded at the end of the Phase 1 study, which included some critical laboratory work, that 0.1-kg/kW megawatt DC/DC converters can be built. This is an order of magnitude lower specific weight than is presently available. A brief description of each of the concepts used to meet the ambitious goals of this program are presented.
Significance of palpable tendon friction rubs in early diffuse cutaneous systemic sclerosis.
Doré, Adam; Lucas, Mary; Ivanco, Dana; Medsger, Thomas A; Domsic, Robyn T
2013-08-01
Palpable tendon friction rubs (TFRs) in systemic sclerosis (SSc; scleroderma) have been associated with diffuse skin thickening, increased disability, and poor survival. Our objective was to quantify the prognostic implications of palpable TFRs on the development of disease complications and longer-term mortality in an incident cohort of early diffuse cutaneous SSc (dcSSc) patients. We identified early dcSSc patients (disease duration <2 years from the first SSc symptom) first evaluated at the University of Pittsburgh Scleroderma Center between 1980 and 2006 and found to have palpable TFRs. These patients were matched 1:1 with the next consecutive early dcSSc patient without TFRs as a control. All had ≥2 clinic visits and 5 years of followup from the first visit. A total of 287 early dcSSc patients with TFR were identified and matched to 287 controls. The median disease duration was 0.83 years in TFR patients and 1.04 years in controls. The median followup was 10.1 years in TFR patients and 7.9 years in controls. Over the course of their illness, patients with TFRs had a >2-fold risk of developing renal crisis and cardiac and gastrointestinal disease complications, even after adjustment for other known risk factors. Patients with TFRs had poorer 5- and 10-year survival rates. Patients with early dcSSc having ≥1 TFRs are at an increased risk of developing renal, cardiac, and gastrointestinal involvement before and after their first Scleroderma Center visit and have reduced survival. Patients presenting with TFRs should be carefully monitored for serious internal organ involvement. Copyright © 2013 by the American College of Rheumatology.
Chen, Jiann-Jong; Kung, Che-Min
2010-09-01
The communication speed between components is far from satisfactory. To achieve high speed, simple control system configuration, and low cost, a new on-chip all-digital three-phase dc/ac power inverter using feedforward and frequency control techniques is proposed. The controller of the proposed power inverter, called the shift register, consists of six-stage D-latch flip-flops with a goal of achieving low-power consumption and area efficiency. Variable frequency is achieved by controlling the clocks of the shift register. One advantage regarding the data signal (D) and the common clock (CK) is that, regardless of the phase difference between the two, all of the D-latch flip-flops are capable of delaying data by one CK period. To ensure stability, the frequency of CK must be six times higher than that of D. The operation frequency of the proposed power inverter ranges from 10 Hz to 2 MHz, and the maximum output loading current is 0.8 A. The prototype of the proposed circuit has been fabricated with TSMC 0.35 μm 2P4M CMOS processes. The total chip area is 2.333 x 1.698 mm2. The three-phase dc/ac power inverter is applicable in uninterrupted power supplies, cold cathode fluorescent lamps, and motors, because of its ability to convert the dc supply voltage into the three-phase ac power sources.
Márquez, Andrés; Gallego, Sergi; Méndez, David; Alvarez, Mariela L; Fernández, Elena; Ortuño, Manuel; Neipp, Cristian; Beléndez, Augusto; Pascual, Inmaculada
2007-09-01
We show an accurate procedure to obtain a Fourier transform (FT) with no dc term using a commercial twisted-nematic liquid-crystal display. We focus on the application to holographic storage of binary data pages, where a drastic decrease of the dc term in the FT is highly desirable. Two different codification schemes are considered: binary pi radians phase modulation and hybrid ternary modulation. Any deviation in the values of the amplitude and phase shift generates the appearance of a strong dc term. Experimental results confirm that the calculated configurations provide a FT with no dc term, thus showing the effectiveness of the proposal.
Gadducci, Angiolo; Cavazzana, Andrea; Cosio, Stefania; DI Cristofano, Claudio; Tana, Roberta; Fanucchi, Antonio; Teti, Giancarlo; Cristofani, Renza; Genazzani, Andrea Riccardo
2009-05-01
The aim of this retrospective study was to assess the predictive value of different clinicopathological variables (patient age, tumour size, FIGO grade, myometrial invasion, lymph-vascular space involvement [LVSI], invasion margins, peri-tumour phlogistic infiltrate and mitotic activity) for the risk of distant haematogenous recurrences in patients with endometrioid-type stage Ib-II endometrial cancer. Between August 1990 and April 2005, 259 patients had undergone laparotomy, peritoneal washing, total abdominal hysterectomy and bilateral salpingo-oophorectomy, with or without pelvic +/- para-aortic lymphadenectomy for endometrioid-type endometrial cancer. Thirty-six (13.9%) patients had developed recurrent disease after a median time of 17 months (range, 2-128 months). The relapse had been locoregional in 9, distant in 21 and both locoregional plus distant in 6 cases. This study assessed 12 patients with FIGO stage Ib-II disease who had developed distant haematogenous recurrences and 20 randomly chosen control patients with FIGO stage Ib-II disease who had remained recurrence-free after a median follow-up of 52 months (range, 37-66 months). Adjuvant therapy had been: no further treatment in 15 patients, external pelvic irradiation in 14 patients, adjuvant external pelvic irradiation plus brachytherapy in 2 patients and platinum-based chemotherapy followed by external pelvic irradiation in 1 patient. The site of distant failure had been the lung in 9 patients, liver in 2 patients and lung plus liver in 1 patient. A concomitant locoregional relapse (vagina or lymph nodes) had occurred in 3 patients. The median interval between surgery and the development of distant failure had been 16.5 months (range, 5-113 months). On univariate analysis, a higher incidence of FIGO grade 3 (50% versus 10%, p=0.0114), outer one-third myometrial invasion (91.7% versus 35.0%, p=0.0051) and LVSI (75.0.% versus 20.0%, p=0.0022) was found in the patients who had developed distant haematogeneous metastases compared to the recurrence-free women. Multivariate analysis showed that LVSI (p=0.0264) and deep myometrial invasion (p=0.0345) were independent predictive variables for the risk of distant haematogeneous failure. Patients with these pathological findings should be enrolled in randomised trials designed to assess the role of adjuvant chemotherapy alone or combined with sequential and/or concomitant external pelvic irradiation.
Zeng, Xi-Lei; Thumati, Naresh R.; Fleisig, Helen B.; Hukezalie, Kyle R.; Savage, Sharon A.; Giri, Neelam; Alter, Blanche P.; Wong, Judy M.Y.
2012-01-01
X-linked dyskeratosis congenita (X-DC) is caused by mutations in the housekeeping nucleolar protein dyskerin. Amino acid changes associated with X-DC are remarkably heterogeneous. Peripheral mononuclear blood cells and fibroblasts isolated from X-DC patients harbor lower steady-state telomerase RNA (TER) levels and shorter telomeres than healthy age-matched controls. Previously, we showed that retroviral expression of recombinant TER, together with expression of recombinant telomerase reverse transcriptase, restored telomere maintenance and proliferative capacity in X-DC patient cells. Using rare X-DC isoforms (▵L37 and A386T dyskerin), we showed that telomere maintenance defects observed in X-DC are solely due to decreased steady-state levels of TER. Disease-associated reductions in steady-state TER levels cause deficiencies in telomere maintenance. Here, we confirm these findings in other primary X-DC patient cell lines coding for the most common (A353V dyskerin) and more clinically severe (K314R and A353V dyskerin) X-DC isoforms. Using cell lines derived from these patients, we also examined the steady-state levels of other hinge-ACA motif RNAs and did not find differences in their in vivo accumulations. We show, for the first time, that purified telomerase holoenzyme complexes from different X-DC cells have normal catalytic activity. Our data confirm that dyskerin promotes TER stability in vivo, endorsing the development of TER supplementation strategies for the treatment of X-DC. PMID:22058290
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guadagnolo, B. Ashleigh; Zagars, Gunar K.; Ballo, Matthew T.
2008-03-01
Purpose: To evaluate the local control rates and patterns of metastatic relapse in patients with localized myxoid liposarcoma treated with conservation surgery and radiotherapy (RT). Patients and Methods: Between 1960 and 2003, 127 patients with non-metastatic myxoid liposarcoma were treated with conservation surgery and RT at our institution. The median patient age was 39 years (range, 14-79 years). Of the 127 patients, 46% underwent preoperative RT (median dose, 50 Gy) and 54% underwent postoperative RT (median dose, 60 Gy). Also, 28% received doxorubicin-based chemotherapy as a part of their treatment. Results: The median follow-up was 9.1 years. The overall survivalmore » rate at 5 and 10 years was 87% and 79%, respectively. The corresponding disease-free survival rates were 81% and 73%. The local control rate at {>=}5 years was 97%. The actuarial rate of distant metastases at 5 and 10 years was 15% and 24%, respectively. Of the 27 patients who developed distant metastases, 48% did so in the retroperitoneum, 22% in other extrapulmonary soft tissues, 22% in the lung, 15% in bone, and 4% in the liver. Conclusion: The results of our study have shown that RT and conservation surgery for localized myxoid liposarcoma provide excellent local control. Distant metastatic relapse tended to occur in the retroperitoneum and other nonpulmonary soft tissues. Therefore, staging and surveillance imaging should include the abdomen and pelvis, as well as the thorax, for patients with localized myxoid liposarcoma.« less
Duan, Xue-Zhang; Wang, Min; Li, Han-Wei; Zhuang, Hui; Xu, Dongping; Wang, Fu-Sheng
2004-11-01
The Type 2 precursor plasmacytoid dendritic cells (pDC) represent the most important cell type in antiviral innate immunity. To understand the function of pDC during hepatitis B virus infection, the frequency and function of circulating pDC were analyzed by flow cytometric analysis, and IFN-alpha secretion of total PBMCs was determined by ELISA assay in 25 healthy subjects and 116 patients at various stages of chronic hepatitis B virus infection (CHB). The number of circulating pDC was found to be significantly lower in patients with CHB and associated liver cirrhosis (LC). The ability of PBMCs to secrete IFN-alpha also decreased significantly. There was a corresponding decrease of circulating NK cells and CD8+ T cells. We observed that lamuvidine antiviral therapy restored the number of circulating pDC and there was a reversal of pDC frequency with the control of HBV replication in chronic HBV patients, indicating these subjects are unlikely to be totally immunocompromised. The decrease of pDC was found to be related to nosocomial infections in LC patients. Our results suggest that CHB patients probably have a quantitative and qualitative impairment of circulating pDC or NK cells, which may be associated with HBV persistent infection as well as the nosocomial infections that arise in LC patients.
Tokita, Daisuke; Sumpter, Tina L.; Raimondi, Giorgio; Zahorchak, Alan F.; Wang, Zhiliang; Nakao, Atsunori; Mazariegos, George V.; Abe, Masanori; Thomson, Angus W.
2008-01-01
Background/Aims The liver is comparatively rich in plasmacytoid (p) dendritic cells (DC),- innate immune effector cells that are also thought to play key roles in the induction and regulation of adaptive immunity. Methods Liver and spleen pDC were purified from fms-like tyrosine kinase ligand-reated control or lipopolysaccharide-injected C57BL/10 mice. Flow cytometric and molecular biologic assays were used to characterize their function and interaction with naturally-occurring regulatory T cells (Treg). Results While IL-10 production was greater for freshly-isolated liver compared with splenic pDC, the former produced less bioactive IL-12p70. Moreover, liver pDC expressed a low Delta4/Jagged1 Notch ligand ratio, skewed towards T helper 2 cell differentiation/cytokine production, and promoted allogeneic CD4+ T cell apoptosis. T cell proliferation in response to liver pDC was, however, enhanced by blocking IL-10 function at the initiation of cultures. In the absence of naturally occurring CD4+CD25+ regulatory T cells, similar levels of T cell proliferation were induced by liver and spleen pDC and the pro-apoptotic activity of liver pDC was reversed. Conclusion The inferior T cell allostimulatory activity of in vivo-stimulated liver pDC may depend on the presence and function of Treg, a property that may contribute to inherent liver tolerogenicity. PMID:18926588
Riepsaame, Joey; van Oudenaren, Adri; den Broeder, Berlinda J. H.; van IJcken, Wilfred F. J.; Pothof, Joris; Leenen, Pieter J. M.
2013-01-01
Dendritic cell (DC) maturation is a tightly regulated process that requires coordinated and timed developmental cues. Here we investigate whether microRNAs are involved in this process. We identify microRNAs in mouse GM-CSF-generated, monocyte-related DC (GM-DC) that are differentially expressed during both spontaneous and LPS-induced maturation and characterize M-CSF receptor (M-CSFR), encoded by the Csf1r gene, as a key target for microRNA-mediated regulation in the final step toward mature DC. MicroRNA-22, -34a, and -155 are up-regulated in mature MHCIIhi CD86hi DC and mediate Csf1r mRNA and protein down-regulation. Experimental inhibition of Csf1r-targeting microRNAs in vitro results not only in sustained high level M-CSFR protein expression but also in impaired DC maturation upon stimulation by LPS. Accordingly, over-expression of Csf1r in GM-DC inhibits terminal differentiation. Taken together, these results show that developmentally regulated microRNAs control Csf1r expression, supplementing previously identified mechanisms that regulate its transcription and protein surface expression. Furthermore, our data indicate a novel function for Csf1r in mouse monocyte-derived DC, showing that down-regulation of M-CSFR expression is essential for final DC maturation. PMID:24198819
Design and modelling of high gain DC-DC converters for fuel cell hybrid electric vehicles
NASA Astrophysics Data System (ADS)
Elangovan, D.; Karthigeyan, V.; Subhanu, B.; Ashwin, M.; Arunkumar, G.
2017-11-01
Transportation (Diesel and petrol internal combustion engine vehicles) approximately contributes to 25.5% of total CO2 emission. Thus diesel and petrol engine vehicles are the most dominant contributors of CO2 emission which leads global warming which causes climate change. The problem of CO2 emission and global warming can be reduced by focusing on renewable energy vehicles. Out of the available renewable energy sources fuel cell is the only source which has reasonable efficiency and can be used in vehicles. But the main disadvantage of fuel cell is its slow response time. So energy storage systems like batteries and super capacitors are used in parallel with the fuel cell. Fuel cell is used during steady state vehicle operation while during transient conditions like starting, acceleration and braking batteries and super capacitors can supply or absorb energy. In this paper a unidirectional fuel cell DC-DC converter and bidirectional energy storage system DC-DC converter is proposed, which can interface dc sources at different voltage levels to the dc bus and also it can independently control the power flow from each energy source to the dc bus and vice versa. The proposed converters are designed and simulated using PSIM version 9.1.1 and gate pulse pattern, input and output voltage waveforms of the converters for steady state operation are studied.
Le Mercier, Philippe; Jacob, Yves; Tanner, Kyle; Tordo, Noël
2002-01-01
By comparing three expression vectors for the rabies virus (Rv) minigenome, we show that the characteristic of the Rv RNA is important for efficient rescue despite its not being crucial for replication. Moreover, we show that the coexpression of the viral proteins from helper Rv and Mokola virus could rescue the Rv minigenome while Rv-related European bat lyssavirus 1 could not, suggesting that the signals controlling transcription and replication are conserved in the distantly related Rv and Mokola virus. PMID:11799201
Study on emergency power control strategy for AC/DC hybrid power system containing VSC-HVDC
NASA Astrophysics Data System (ADS)
Liu, Lin; Hu, Zhenda; Ye, Rong; Lin, Zhangsui; Yang, Xiaodong; Yi, Yang
2018-04-01
This paper presents a comprehensive emergency power control strategy for AC/DC hybrid power systems containing VSC-HVDC. Firstly, the paper analyzes the power support of the VSC-HVDC to the AC lines using the Power Transferring Relativity Factor (PTRF). Then the power adjustment of the VSC-HVDC in several different circumstances are calculated. Finally, the online power control strategies of VSC-HVDC are designed, which could rapidly control the power of the VSC-HVDC, keeping the power flow of AC lines below the upper limit. Furthermore, the strategy is proven to be effective by the simulations with EMTDC/PSCAD.
NASA Technical Reports Server (NTRS)
Perry, B., III
1981-01-01
Comparisons are presented analytically predicted and experimental turbulence responses of a wind tunnel model of a DC-10 derivative wing equipped with an active control system. The active control system was designed for the purpose of flutter suppression, but it had additional benefit of alleviating gust loads (wing bending moment) by about 25%. Comparisions of various wing responses are presented for variations in active control system parameters and tunnel speed. The analytical turbulence responses were obtained using DYLOFLEX, a computer program for dynamic loads analyses of flexible airplanes with active controls. In general, the analytical predictions agreed reasonably well with the experimental data.
14 CFR 93.331 - Purpose and applicability of this subpart.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Washington, DC... prescribes special air traffic rules for aircraft operating in the Washington, DC Metropolitan Area. Because identification and control of aircraft is required for reasons of national security, the areas described in this...
14 CFR 93.331 - Purpose and applicability of this subpart.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Washington, DC... prescribes special air traffic rules for aircraft operating in the Washington, DC Metropolitan Area. Because identification and control of aircraft is required for reasons of national security, the areas described in this...
Non-native wisteria control with herbicides
James H. Miller
2006-01-01
Chinese wisteria (Wisteria sinensis (Sims) DC) is a deciduous, perennial, leguminous woody vine that is invasive throughout much of the Eastern U.S. A related wisteria that invades the same range is Japanese wisteria (W. floribunda (Willd.) DC). It is difficult to distinguish Chinese from Japanese wisteria due to similar leaves,...
Efficient/reliable dc-to-dc inverter circuit
NASA Technical Reports Server (NTRS)
Pasciutti, E. R.
1970-01-01
Feedback loop, which contains an inductor in series with a saturable reactor, is added to a standard inverter circuit to permit the inverter power transistors to be switched in a controlled and efficient manner. This inverter is applicable where the power source has either high or low impedance properties.
Cockburn, J F; Maddern, G J; Wemyss-Holden, S A
2007-03-01
To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver. Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Omega or radiofrequency energy input fell below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis. With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p<0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm). Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation alone.
Safety and activity of PD-1 blockade-activated DC-CIK cells in patients with advanced solid tumors.
Chen, Chang-Long; Pan, Qiu-Zhong; Weng, De-Sheng; Xie, Chuan-Miao; Zhao, Jing-Jing; Chen, Min-Shan; Peng, Rui-Qing; Li, Dan-Dan; Wang, Ying; Tang, Yan; Wang, Qi-Jing; Zhang, Zhi-Ling; Zhang, Xiao-Fei; Jiang, Li-Juan; Zhou, Zi-Qi; Zhu, Qian; He, Jia; Liu, Yuan; Zhou, Fang-Jian; Xia, Jian-Chuan
2018-01-01
Cytokine-induced killer (CIK) cells that are stimulated using mature dendritic cells (DCs), referred to as (DC-CIK cells) exhibit superior anti-tumor potency. Anti-programmed death-1 (PD-1) antibodies reinvigorate T cell-mediated antitumor immunity. This phase I study aimed to assess the safety and clinical activity of immunotherapy with PD-1 blockade (pembrolizumab)-activated autologous DC-CIK cells in patients with advanced solid tumors. Patients with selected types of advanced solid tumors received a single intravenous infusion of activated autologous DC-CIK cells weekly for the first month and every 2 weeks thereafter. The primary end points were safety and adverse event (AE) profiles. Antitumor responses, overall survival (OS), progression-free survival (PFS) and cytolytic activity were secondary end points. Treatment-related AEs occurred in 20/31 patients. Grade 3 or 4 toxicities, including fever and chills, were observed in two patients. All treatment-related AEs were reversible or controllable. The cytotoxicity of DC-CIK cells induced up-regulation of PD-L1 expression on autologous tumor cells. When activated using pembrolizumab ex vivo , DC-CIK cells exerted superior antitumor properties and elevated IFN-γ secretion. Objective responses (complete or partial responses) were observed in 7 of the 31patients.These responses were durable, with 6 of 7 responses lasting more than 5 months. The overall disease control rate in the patients was 64.5%. At the time of this report, the median OS and PFS were 270 and 162 days, respectively. In conclusions, treatment with pembrolizumab-activated autologous DC-CIK cells was safe and exerted encouraging antitumor activity in advanced solid tumors. A larger phase II trial is warranted.
Dendritic cells in uninfected infants born to hepatitis B virus-positive mothers.
Koumbi, Lemonica J; Papadopoulos, Nikolaos G; Anastassiadou, Vassiliki; Machaira, Maria; Kafetzis, Dimitris A; Papaevangelou, Vassiliki
2010-07-01
Plasmacytoid dendritic cells (pDCs) play a central role in antiviral immunity, detecting viruses via Toll-like receptors (TLR) and producing in response vast amounts of type I interferons (IFNs). Hepatitis B virus (HBV) causes chronic infection after vertical transmission. This study investigated whether an HBV-infected maternal environment might influence DC numbers and pDC function in uninfected infants. Blood was collected from inactive HBsAg carrier and control mothers and their infants at birth and 1 and 6 months of age. HBV DNA was measured in maternal and neonatal perinatal sera using real-time PCR. The circulating frequencies of myeloid DCs (mDCs) and pDCs were determined in the babies by flow cytometry. Peripheral blood mononuclear cells (PBMCs) and cord blood pDCs were stimulated with resiquimod, and alpha interferon (IFN-alpha) production and the pDC phenotype were assessed. The effect of the common-cold virus, rhinovirus (RV), on resiquimod stimulation was also determined. HBV DNA was detected in 62.3% of the mothers and 41% of their infants. DC numbers and pDC functions were similar between subjects and controls and were not correlated with maternal or neonatal viremia. RV infection did not induce pDC maturation until the age of 6 months, and it reduced TLR7-dependent resiquimod-induced IFN-alpha production similarly in both groups. Although the DC system is immature at birth, DCs of uninfected neonates of HBV-positive mothers are competent to initiate and maintain T-cell responses. RV is a weak inducer of IFN-alpha production until the age of 6 months and inhibits IFN-alpha responses triggered by the TLR7 pathway.
NASA Astrophysics Data System (ADS)
Gladwin, D.; Stewart, P.; Stewart, J.
2011-02-01
This article addresses the problem of maintaining a stable rectified DC output from the three-phase AC generator in a series-hybrid vehicle powertrain. The series-hybrid prime power source generally comprises an internal combustion (IC) engine driving a three-phase permanent magnet generator whose output is rectified to DC. A recent development has been to control the engine/generator combination by an electronically actuated throttle. This system can be represented as a nonlinear system with significant time delay. Previously, voltage control of the generator output has been achieved by model predictive methods such as the Smith Predictor. These methods rely on the incorporation of an accurate system model and time delay into the control algorithm, with a consequent increase in computational complexity in the real-time controller, and as a necessity relies to some extent on the accuracy of the models. Two complementary performance objectives exist for the control system. Firstly, to maintain the IC engine at its optimal operating point, and secondly, to supply a stable DC supply to the traction drive inverters. Achievement of these goals minimises the transient energy storage requirements at the DC link, with a consequent reduction in both weight and cost. These objectives imply constant velocity operation of the IC engine under external load disturbances and changes in both operating conditions and vehicle speed set-points. In order to achieve these objectives, and reduce the complexity of implementation, in this article a controller is designed by the use of Genetic Programming methods in the Simulink modelling environment, with the aim of obtaining a relatively simple controller for the time-delay system which does not rely on the implementation of real time system models or time delay approximations in the controller. A methodology is presented to utilise the miriad of existing control blocks in the Simulink libraries to automatically evolve optimal control structures.
Pulsed DC Electric Field–Induced Differentiation of Cortical Neural Precursor Cells
Chang, Hui-Fang; Lee, Ying-Shan; Tang, Tang K.; Cheng, Ji-Yen
2016-01-01
We report the differentiation of neural stem and progenitor cells solely induced by direct current (DC) pulses stimulation. Neural stem and progenitor cells in the adult mammalian brain are promising candidates for the development of therapeutic neuroregeneration strategies. The differentiation of neural stem and progenitor cells depends on various in vivo environmental factors, such as nerve growth factor and endogenous EF. In this study, we demonstrated that the morphologic and phenotypic changes of mouse neural stem and progenitor cells (mNPCs) could be induced solely by exposure to square-wave DC pulses (magnitude 300 mV/mm at frequency of 100-Hz). The DC pulse stimulation was conducted for 48 h, and the morphologic changes of mNPCs were monitored continuously. The length of primary processes and the amount of branching significantly increased after stimulation by DC pulses for 48 h. After DC pulse treatment, the mNPCs differentiated into neurons, astrocytes, and oligodendrocytes simultaneously in stem cell maintenance medium. Our results suggest that simple DC pulse treatment could control the fate of NPCs. With further studies, DC pulses may be applied to manipulate NPC differentiation and may be used for the development of therapeutic strategies that employ NPCs to treat nervous system disorders. PMID:27352251
Discovery of novel immunostimulants by dendritic-cell–based functional screening
Mizumoto, Norikatsu; Gao, Jimin; Matsushima, Hironori; Ogawa, Yasushi; Tanaka, Hiroaki; Takashima, Akira
2005-01-01
Immunostimulants represent an emerging class of drugs for the treatment of infectious disorders and cancer. CpG oligonucleotides and imiquimod, prototypic drugs in this category, are now known to activate dendritic cells (DCs). Here we report the development of a highly sensitive, unbiased functional screen to detect DC-stimulatory signals. Because interleukin-1β (IL-1β) mRNA expression is closely associated with DC activation, we engineered DCs to stably express a fluorescent marker gene under the control of IL-1β promoter. By screening about 3000 compounds with the resulting DC biosensor clone, we identified DC-stimulatory potentials of topoisomerase I inhibitors (camptothecin derivatives) and microtubule depolymerizing drugs (colchicine and podophyllotoxin). In response to treatment with each agent, bone marrow–derived DC preparations exhibited characteristic phenotypic and/or functional changes associated with DC activation. All of these agents also triggered nuclear factor–κB (NFκB) activation in DCs, suggesting a common pharmacologic mechanism of action. Furthermore, locally administered colchicine induced in situ maturation and migration of DCs and augmented both humoral and cellular immune responses. These results support the practical utility of the DC-based biosensor system to discover novel DC-targeted immunostimulants and unveil previously unrecognized (and totally unexpected) pharmacologic activities of several drugs that are commonly used for the treatment of various disorders. PMID:16002424
Woltman, Andrea M.; Shi, Cui C.; Janssen, Harry L. A.
2011-01-01
Chronic hepatitis B virus (HBV) infection is caused by inadequate anti-viral immunity. Activation of plasmacytoid dendritic cells (pDC) leading to IFNα production is important for effective anti-viral immunity. Hepatitis B virus (HBV) infection lacks IFNα induction in animal models and patients and chronic HBV patients display impaired IFNα production by pDC. Therefore, HBV and HBV-derived proteins were examined for their effect on human pDC in vitro. In addition, the in vitro findings were compared to the function of pDC derived from chronic HBV patients ex vivo. In contrast to other viruses, HBV did not activate pDC. Moreover, HBV and HBsAg abrogated CpG-A/TLR9-induced, but not Loxoribine/TLR7-induced, mTOR-mediated S6 phosphorylation, subsequent IRF7 phosphorylation and IFNα gene transcription. HBV/HBsAg also diminished upregulation of co-stimulatory molecules, production of TNFα, IP-10 and IL-6 and pDC-induced NK cell function, whereas TLR7-induced pDC function was hardly affected. In line, HBsAg preferentially bound to TLR9-triggered pDC demonstrating that once pDC are able to bind HBV/HBsAg, the virus exerts its immune regulatory effect. HBV not only directly interfered with pDC function, but also indirectly by interfering with monocyte-pDC interaction. Also HBeAg diminished pDC function to a certain extent, but via another unknown mechanism. Interestingly, patients with HBeAg-positive chronic hepatitis B displayed impaired CpG-induced IFNα production by pDC without significant alterations in Loxoribine-induced pDC function compared to HBeAg-negative patients and healthy controls. The lack of activation and the active inhibition of pDC by HBV may both contribute to HBV persistence. The finding that the interaction between pDC and HBV may change upon activation may aid in the identification of a scavenging receptor supporting immunosuppressive effects of HBV and also in the design of novel treatment strategies for chronic HBV. PMID:21246041
Wireless power charging using point of load controlled high frequency power converters
Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.
2015-10-13
An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.
Tumor Microenvironment of Metastasis and Risk of Distant Metastasis of Breast Cancer
Xue, Xiaonan; Lin, Hung-Mo; D’Alfonso, Timothy M.; Ginter, Paula S.; Oktay, Maja H.; Robinson, Brian D.; Ginsberg, Mindy; Gertler, Frank B.; Glass, Andrew G.; Sparano, Joseph A.; Condeelis, John S.; Jones, Joan G.
2014-01-01
Background Tumor microenvironment of metastasis (TMEM), consisting of direct contact between a macrophage, an endothelial cell, and a tumor cell, has been associated with metastasis in both rodent mammary tumors and human breast cancer. We prospectively examined the association between TMEM score and risk of distant metastasis and compared risk associated with TMEM score with that associated with IHC4. Methods We conducted a case–control study nested within a cohort of 3760 patients with invasive ductal breast carcinoma diagnosed between 1980 and 2000 and followed through 2010. Case patients were women who developed a subsequent distant metastasis; control subjects were matched (1:1) on age at and calendar year of primary diagnosis. TMEM was assessed by triple immunostain and IHC4 by standard methods; slides were read by pathologists blinded to outcome. Odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using logistic regression, adjusted for clinical variables. A Receiver Operating Characteristic analysis was performed, and the area under the curve was estimated. All statistical tests were two-sided. Results TMEM score was associated with increased risk of distant metastasis in estrogen receptor (ER)+/human epidermal growth factor receptor (HER2)− tumors (multivariable OR high vs low tertile = 2.70; 95% CI = 1.39 to 5.26; P trend = .004), whereas IHC4 score had a borderline positive association (OR10 unit increase = 1.06; 95% CI = 1.00 to 1.13); the association for TMEM score persisted after adjustment for IHC4 score. The area under the curve for TMEM, adjusted for clinical variables, was 0.78. Neither TMEM score nor IHC4 score was independently associated with metastatic risk overall or in the triple negative or HER2+ subgroups. Conclusions TMEM score predicted risk of distant metastasis in ER+/HER2− breast cancer independently of IHC4 score and classical clinicopathologic features. PMID:24895374
Tumor microenvironment of metastasis and risk of distant metastasis of breast cancer.
Rohan, Thomas E; Xue, Xiaonan; Lin, Hung-Mo; D'Alfonso, Timothy M; Ginter, Paula S; Oktay, Maja H; Robinson, Brian D; Ginsberg, Mindy; Gertler, Frank B; Glass, Andrew G; Sparano, Joseph A; Condeelis, John S; Jones, Joan G
2014-08-01
Tumor microenvironment of metastasis (TMEM), consisting of direct contact between a macrophage, an endothelial cell, and a tumor cell, has been associated with metastasis in both rodent mammary tumors and human breast cancer. We prospectively examined the association between TMEM score and risk of distant metastasis and compared risk associated with TMEM score with that associated with IHC4. We conducted a case-control study nested within a cohort of 3760 patients with invasive ductal breast carcinoma diagnosed between 1980 and 2000 and followed through 2010. Case patients were women who developed a subsequent distant metastasis; control subjects were matched (1:1) on age at and calendar year of primary diagnosis. TMEM was assessed by triple immunostain and IHC4 by standard methods; slides were read by pathologists blinded to outcome. Odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using logistic regression, adjusted for clinical variables. A Receiver Operating Characteristic analysis was performed, and the area under the curve was estimated. All statistical tests were two-sided. TMEM score was associated with increased risk of distant metastasis in estrogen receptor (ER)(+)/human epidermal growth factor receptor (HER2)(-) tumors (multivariable OR high vs low tertile = 2.70; 95% CI = 1.39 to 5.26; P trend = .004), whereas IHC4 score had a borderline positive association (OR10 unit increase = 1.06; 95% CI = 1.00 to 1.13); the association for TMEM score persisted after adjustment for IHC4 score. The area under the curve for TMEM, adjusted for clinical variables, was 0.78. Neither TMEM score nor IHC4 score was independently associated with metastatic risk overall or in the triple negative or HER2(+) subgroups. TMEM score predicted risk of distant metastasis in ER(+)/HER2(-) breast cancer independently of IHC4 score and classical clinicopathologic features. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Guo, Qi; Cheng, Liu-Yong; Chen, Li; Wang, Hong-Fu; Zhang, Shou
2014-10-01
The existing distributed quantum gates required physical particles to be transmitted between two distant nodes in the quantum network. We here demonstrate the possibility to implement distributed quantum computation without transmitting any particles. We propose a scheme for a distributed controlled-phase gate between two distant quantum-dot electron-spin qubits in optical microcavities. The two quantum-dot-microcavity systems are linked by a nested Michelson-type interferometer. A single photon acting as ancillary resource is sent in the interferometer to complete the distributed controlled-phase gate, but it never enters the transmission channel between the two nodes. Moreover, we numerically analyze the effect of experimental imperfections and show that the present scheme can be implemented with high fidelity in the ideal asymptotic limit. The scheme provides further evidence of quantum counterfactuality and opens promising possibilities for distributed quantum computation.
Moss, Nicholas J; Magaret, Amalia; Laing, Kerry J; Kask, Angela Shaulov; Wang, Minna; Mark, Karen E; Schiffer, Joshua T; Wald, Anna; Koelle, David M
2012-09-01
Leukocytes participate in the immune control of herpes simplex virus (HSV). Data from HIV coinfections, germ line mutations, and case reports suggest involvement of CD4 T cells and plasmacytoid dendritic cells (pDC). We investigated the relationships between these cells and recurrent genital herpes disease severity in the general population. Circulating CD4 T-cell responses to HSV-2 were measured in specimens from 67 immunocompetent individuals with measured genital lesion and HSV shedding rates. Similarly, pDC number and functional responses to HSV-2 were analyzed in 40 persons. CD4 responses and pDC concentrations and responses ranged as much as 100-fold between persons while displaying moderate within-person consistency over time. No correlations were observed between these immune response parameters and genital HSV-2 severity. Cytomegalovirus (CMV) coinfection was not correlated with differences in HSV-2-specific CD4 T-cell responses. The CD4 T-cell response to HSV-2 was much more polyfunctional than was the response to CMV. These data suggest that other immune cell subsets with alternate phenotypes or anatomical locations may be responsible for genital herpes control in chronically infected individuals.
NASA Technical Reports Server (NTRS)
Lukemire, Alan T. (Inventor)
1995-01-01
A pulse-width modulated DC-to-DC power converter including a first inductor, i.e. a transformer or an equivalent fixed inductor equal to the inductance of the secondary winding of the transformer, coupled across a source of DC input voltage via a transistor switch which is rendered alternately conductive (ON) and nonconductive (OFF) in accordance with a signal from a feedback control circuit is described. A first capacitor capacitively couples one side of the first inductor to a second inductor which is connected to a second capacitor which is coupled to the other side of the first inductor. A circuit load shunts the second capacitor. A semiconductor diode is additionally coupled from a common circuit connection between the first capacitor and the second inductor to the other side of the first inductor. A current sense transformer generating a current feedback signal for the switch control circuit is directly coupled in series with the other side of the first inductor so that the first capacitor, the second inductor and the current sense transformer are connected in series through the first inductor. The inductance values of the first and second inductors, moreover, are made identical. Such a converter topology results in a simultaneous voltsecond balance in the first inductance and ampere-second balance in the current sense transformer.
Moss, Nicholas J.; Magaret, Amalia; Laing, Kerry J.; Kask, Angela Shaulov; Wang, Minna; Mark, Karen E.; Schiffer, Joshua T.; Wald, Anna
2012-01-01
Leukocytes participate in the immune control of herpes simplex virus (HSV). Data from HIV coinfections, germ line mutations, and case reports suggest involvement of CD4 T cells and plasmacytoid dendritic cells (pDC). We investigated the relationships between these cells and recurrent genital herpes disease severity in the general population. Circulating CD4 T-cell responses to HSV-2 were measured in specimens from 67 immunocompetent individuals with measured genital lesion and HSV shedding rates. Similarly, pDC number and functional responses to HSV-2 were analyzed in 40 persons. CD4 responses and pDC concentrations and responses ranged as much as 100-fold between persons while displaying moderate within-person consistency over time. No correlations were observed between these immune response parameters and genital HSV-2 severity. Cytomegalovirus (CMV) coinfection was not correlated with differences in HSV-2-specific CD4 T-cell responses. The CD4 T-cell response to HSV-2 was much more polyfunctional than was the response to CMV. These data suggest that other immune cell subsets with alternate phenotypes or anatomical locations may be responsible for genital herpes control in chronically infected individuals. PMID:22761381
Learning fuzzy logic control system
NASA Technical Reports Server (NTRS)
Lung, Leung Kam
1994-01-01
The performance of the Learning Fuzzy Logic Control System (LFLCS), developed in this thesis, has been evaluated. The Learning Fuzzy Logic Controller (LFLC) learns to control the motor by learning the set of teaching values that are generated by a classical PI controller. It is assumed that the classical PI controller is tuned to minimize the error of a position control system of the D.C. motor. The Learning Fuzzy Logic Controller developed in this thesis is a multi-input single-output network. Training of the Learning Fuzzy Logic Controller is implemented off-line. Upon completion of the training process (using Supervised Learning, and Unsupervised Learning), the LFLC replaces the classical PI controller. In this thesis, a closed loop position control system of a D.C. motor using the LFLC is implemented. The primary focus is on the learning capabilities of the Learning Fuzzy Logic Controller. The learning includes symbolic representation of the Input Linguistic Nodes set and Output Linguistic Notes set. In addition, we investigate the knowledge-based representation for the network. As part of the design process, we implement a digital computer simulation of the LFLCS. The computer simulation program is written in 'C' computer language, and it is implemented in DOS platform. The LFLCS, designed in this thesis, has been developed on a IBM compatible 486-DX2 66 computer. First, the performance of the Learning Fuzzy Logic Controller is evaluated by comparing the angular shaft position of the D.C. motor controlled by a conventional PI controller and that controlled by the LFLC. Second, the symbolic representation of the LFLC and the knowledge-based representation for the network are investigated by observing the parameters of the Fuzzy Logic membership functions and the links at each layer of the LFLC. While there are some limitations of application with this approach, the result of the simulation shows that the LFLC is able to control the angular shaft position of the D.C. motor. Furthermore, the LFLC has better performance in rise time, settling time and steady state error than to the conventional PI controller. This abstract accurately represents the content of the candidate's thesis. I recommend its publication.
When do I wear me out? Mental simulation and the diminution of self-control.
Macrae, C Neil; Christian, Brittany M; Golubickis, Marius; Karanasiou, Magdalene; Troksiarova, Lenka; McNamara, Diana L; Miles, Lynden K
2014-08-01
Exerting self-control can diminish people's capacity to engage in subsequent acts of behavioral regulation, a phenomenon termed ego depletion. But what of imaginary regulatory experiences-does simulated restraint elicit comparable lapses in self-control? Here we demonstrate such effects under theoretically tractable imagery conditions. Across 3 experiments, temporal, structural, and spatial components of mental simulation were observed to drive the efficacy of imaginary self-control. In Experiment 1, lapses in restraint (i.e., financial impulsivity) were more pronounced when imaginary regulation (i.e., dietary restraint) focused on an event in the near versus distant future. In Experiment 2, comparable effects (i.e., increased stereotyping) emerged when simulated self-control (i.e., emotional suppression) was imagined from a first-person (cf. third-person) visual perspective. In Experiment 3, restraint was diminished (i.e., increased risk taking) when self-regulation (i.e., action control) centered on an event at a near versus distant location. These findings further delineate the conditions under which mental simulation impacts core aspects of social-cognitive functioning. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Position control of an electro-pneumatic system based on PWM technique and FLC.
Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad
2014-03-01
In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.