DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersson, B.
This paper will present the status of the development of district cooling systems in Scandinavia over the last 5 years. It will describe the technologies used in the systems that have been constructed as well as the options considered in different locations. It will identify the drivers for the development of the cooling business to-date, and what future drivers for a continuing development of district cooling in Sweden. To-date, approximately 25 different cities of varying sizes have completed feasibility studies to determine if district cooling is an attractive option. In a survey, that was conducted by the Swedish District Heatingmore » Association, some 25 cities expected to have district cooling systems in place by the year 2000. In Sweden, district heating systems with hot water is very common. In many cases, it is simply an addition to the current service for the district heating company to also supply district cooling to the building owners. A parallel from this can be drawn to North America where district cooling systems now are developing rapidly. I am convinced that in these cities a district heating service will be added as a natural expansion of the district cooling company`s service.« less
A novel stochastic modeling method to simulate cooling loads in residential districts
An, Jingjing; Yan, Da; Hong, Tianzhen; ...
2017-09-04
District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3)more » a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.« less
A novel stochastic modeling method to simulate cooling loads in residential districts
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, Jingjing; Yan, Da; Hong, Tianzhen
District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3)more » a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitola, J.P.
In two year`s time, Unicorn Thermal Technologies has grown into one of the largest district cooling systems of 25,000 tons with a 1996 plan to grow to 40,000 tons. This growth is attributed to the development and implementation of a marketing and sales plan based on thorough market research and innovative marketing and sales strategies, and the consistent implementation of those strategies. The beginning of the sales effort was focused around the company`s first district cooling facility, However, it quickly grew into a much broader vision as market acceptance increased. Although the district energy industry has often based its messagemore » on being a low cost energy provider, market research and early sales experience indicated that customers choose district cooling as a value added service. As customers began to reserve capacity in the first plant, the idea that district cooling is a value added service and not a commodity energy product was continually reinforced through marketing communications. Although this analysis is a review of developing a district energy system in a competitive urban market, it purposely avoids a long winded discussion of head to head competition.« less
District heating and cooling feasibility study, Dunkirk, New York
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The objective of this project is to perform a preliminary investigation of the technical and economic feasibility of implementing a district heating and cooling (DHC) system in the City of Dunkirk, New York. The study was conducted by first defining a heating and cooling (HC) load service area. Then, questionnaires were sent to prospective DHC customers. After reviewing the owners responses, large consumers of energy were interviewed for more detail of their HC systems, including site visits, to determine possibilities of retrofitting their systems to district heating and cooling. Peak HC loads for the buildings were estimated by Burns andmore » Roe's in-house computer programs. Based on the peak loads, certain customers were determined for suitability as anchor customers. Various options using cogeneration were investigated for possible HC sources. Equipment for HC sources and HC loads were sized and their associated costs estimated. Finally, economic analyses were performed. The conclusion is that it is technically and economically feasible to implement a district heating and cooling system in the City of Dunkirk. 14 figs., 15 tabs.« less
Steamtown District Heating and Cooling Project, Scranton, Pennsylvania. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This report summarizes the activities of a study intended to examine the feasibility of a district heating and cooling alternative for the Steamtown National Historic Site in Scranton, PA. The objective of the study was to investigate the import of steam from the existing district heating system in Scranton which is operated by the Community Central Energy Corporation and through the use of modern technology provide hot and chilled water to Steamtown for its internal heating and cooling requirements. Such a project would benefit Steamtown by introducing a clean technology, eliminating on-site fuel use, avoiding first costs for central heatingmore » and cooling plants and reducing operation and maintenance expenditures. For operators of the existing district heating system, this project represents an opportunity to expand their customer base and demonstrate new technologies. The study was conducted by Joseph Technology Corporation, Inc. and performed for the Community Central Energy Corporation through a grant by the US Department of Energy. Steamtown was represented by the National Park Service, the developers of the site.« less
A thermodynamic analysis of a novel bidirectional district heating and cooling network
Zarin Pass, R.; Wetter, M.; Piette, M. A.
2017-11-29
In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on themore » thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.« less
A thermodynamic analysis of a novel bidirectional district heating and cooling network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zarin Pass, R.; Wetter, M.; Piette, M. A.
In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on themore » thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarrell, Mark
Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.
Benchmark for Performance: Geothermal Applications in Lincoln Public Schools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durfee, D.J.; Hughes, P.J.; Martin, M.A.
1999-06-19
Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident among the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less
Benchmark for performance: Geothermal applications in Lincoln public schools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shonder, J.A.; Martin, M.A.; Sharp, T.R.
1999-07-01
Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however, these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident amongst the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-06-19
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 cents/ft{sup 2}-yr, WCC/GSB schools at 3.73 cents/ft{sup 2}-yr, and WCC/GHWB schools at 6.07 cents/ft{sup 2}-yr. Because of tax-exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2}=O.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-07-01
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four new elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service, and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACC/GHWB), water-cooled chiller with gas-fired hot water boiler (WCC/GHWB), or water-cooled chiller with gas-fired steam boiler (WCC/GSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13{cents}/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.884{cents}/ft{sup 2}-yr, WCC/GSB schools at 3.73{cents}/ft{sup 2}-yr, and WCC/GHWB schools at 6.07{cents}/ft{sup 2}-yr. Because of tax exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2} = 0.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
NASA Astrophysics Data System (ADS)
Tong, Kangkang; Fang, Andrew; Yu, Huajun; Li, Yang; Shi, Lei; Wang, Yangjun; Wang, Shuxiao; Ramaswami, Anu
2017-12-01
Utilizing low-grade waste heat from industries to heat and cool homes and businesses through fourth generation district energy systems (DES) is a novel strategy to reduce energy use. This paper develops a generalizable methodology to estimate the energy saving potential for heating/cooling in 20 cities in two Chinese provinces, representing cold winter and hot summer regions respectively. We also conduct a life-cycle analysis of the new infrastructure required for energy exchange in DES. Results show that heating and cooling energy use reduction from this waste heat exchange strategy varies widely based on the mix of industrial, residential and commercial activities, and climate conditions in cities. Low-grade heat is found to be the dominant component of waste heat released by industries, which can be reused for both district heating and cooling in fourth generation DES, yielding energy use reductions from 12%-91% (average of 58%) for heating and 24%-100% (average of 73%) for cooling energy use in the different cities based on annual exchange potential. Incorporating seasonality and multiple energy exchange pathways resulted in energy savings reductions from 0%-87%. The life-cycle impact of added infrastructure was small (<3% for heating) and 1.9% ~ 6.5% (cooling) of the carbon emissions from fuel use in current heating or cooling systems, indicating net carbon savings. This generalizable approach to delineate waste heat potential can help determine suitable cities for the widespread application of industrial waste heat re-utilization.
ERIC Educational Resources Information Center
Praeger, Charles E.
2005-01-01
Amid climbing energy costs and tightening budgets, administrators at school districts, colleges and universities are looking for all avenues of potential savings while promoting sustainable communities. Cool metal roofing can save schools money and promote sustainable design at the same time. Cool metal roofing keeps the sun's heat from collecting…
Energy Retrofit Creates an Efficient Building.
ERIC Educational Resources Information Center
Freeman, Laurie
1997-01-01
After 20 years of inadequate heating and cooling, an Indiana school district took advantage of a 1994 state law that allows school districts to bypass the "low-bidder wins" restriction. The district established a guaranteed energy-saving contract for a climate-control-improvements package to retrofit the junior-senior high school. (MLF)
Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Im, Piljae; Liu, Xiaobing; Henderson, Jr., Hugh
With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station Southmore » (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district GSHP system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1979-01-01
The feasibility analysis and evaluation of the Piqua, Ohio District Heating and Cooling Demonstration program is being conducted by the Piqua Municipal Power Co., the Piqua Law Dept., the Public Works Dept., a firm of economic analysts, and the Georgia Tech Engineering Dept. This volume contains information on the organization and composition of the demonstration team; characterization of the Piqua community; and the technical, environmental, institutional; financial, and economic assessments of the project. (LCL)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This final report of Phase I of the study presents Task 4, Technical Review and Assessment. The most-promising district-heating concept identified in the Phase I study for the Public Service Electric and Gas Company, Newark, New Jersey, is a hot-water system in which steam is extracted from an existing turbine and used to drive a new, small backpressure turbine-generator. The backpressure turbine provides heat for district heating and simultaneously provides additional electric-generating capacity to partially offset the capacity lost due to the steam extraction. This approach is the most-economical way to retrofit the stations studied for district heating while minimizingmore » electric-capacity loss. Nine fossil-fuel-fired stations within the PSE and G system were evaluated for possibly supplying heat for district heating and cooling in cogeneration operations, but only three were selected to supply the district-heating steam. They are Essex, Hudson, and Bergen. Plant retrofit, thermal distribution schemes, consumer-conversion scheme, and consumer-metering system are discussed. Extensive technical information is provided in 16 appendices, additional tables, figures, and drawings. (MCW)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gleason, T.C.J.
1992-06-01
The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.
Building a Construction Curriculum for Your School District
ERIC Educational Resources Information Center
Ruder, Robert
2010-01-01
Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for…
A community outbreak of Legionnaires' disease: evidence of a cooling tower as the source.
Sabria, M; Alvarez, J; Dominguez, A; Pedrol, A; Sauca, G; Salleras, L; Lopez, A; Garcia-Nuñez, M A; Parron, I; Barrufet, M P
2006-07-01
A community outbreak of Legionella pneumonia in the district of Cerdanyola, Mataró (Catalonia, Spain) was investigated in an epidemiological, environmental and molecular study. Each patient was interviewed to ascertain personal risk-factors and the clinical and epidemiological data. Isolates of Legionella from patients and water samples were subtyped by pulsed-field gel electrophoresis. Between 7 August and 25 August 2002, 113 cases of Legionella pneumonia fulfilling the outbreak case definition criteria were reported, with 84 (74%) cases being located within a 500-m radius of the suspected cooling tower source. In this area, the relative risk of being infected was 54.6 (95% CI 25.3-118.1) compared with individuals living far from the cooling tower. Considering the population residing in the Cerdanyola district (28,256 inhabitants) as a reference population, the attack rate for the outbreak was 399.9 cases/100,000 inhabitants, and the case fatality rate was 1.8%. A single DNA subtype was observed among the ten clinical isolates, and one of the subtypes from the cooling tower matched exactly with the clinical subtype. Nine days after closing the cooling tower, new cases of pneumonia caused by Legionella ceased to appear. The epidemiological features of the outbreak, and the microbiological and molecular investigations, implicated the cooling tower as the source of infection.
Solar Thermal Demonstration Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biesinger, K; Cuppett, D; Dyer, D
2012-01-30
HVAC Retrofit and Energy Efficiency Upgrades at Clark High School, Las Vegas, Nevada The overall objectives of this project are to increase usage of alternative/renewable fuels, create a better and more reliable learning environment for the students, and reduce energy costs. Utilizing the grant resources and local bond revenues, the District proposes to reduce electricity consumption by installing within the existing limited space, one principal energy efficient 100 ton adsorption chiller working in concert with two 500 ton electric chillers. The main heating source will be primarily from low nitrogen oxide (NOX), high efficiency natural gas fired boilers. With themore » use of this type of chiller, the electric power and cost requirements will be greatly reduced. To provide cooling to the information technology centers and equipment rooms of the school during off-peak hours, the District will install water source heat pumps. In another measure to reduce the cooling requirements at Clark High School, the District will replace single pane glass and metal panels with Kalwall building panels. An added feature of the Kalwall system is that it will allow for natural day lighting in the student center. This system will significantly reduce thermal heat/cooling loss and control solar heat gain, thus delivering significant savings in heating ventilation and air conditioning (HVAC) costs.« less
Ground Source Geothermal District Heating and Cooling System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowe, James William
2016-10-21
Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reducemore » worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-08
... industrial use. Potable water in the area is supplied to residents either through the Scriba Water District... and drift losses from the cooling tower. NMP2 has its own cooling water intake and discharge... service water system and makeup to the circulating water system to replace evaporation and drift losses...
ERIC Educational Resources Information Center
WHITESIDES, M.M.
THIS REPORT IS A COMPILATION OF DATA ON ELECTRIC AIR CONDITIONING COSTS, OPERATIONS AND MAINTENANCE. AIR CONDITIONING UNITS ARE COMPARED IN TERMS OF ELECTRIC VERSUS NON-ELECTRIC, AUTOMATIC VERSUS OPERATED, AIR COOLED VERSUS WATER COOLED, RECIPROCATING VERSUS CENTRIFUGAL COMPRESSORS, SPACE AND NOISE, REHEAT, MAINTENANCE AND ORIGINAL COST. DATA ARE…
Analysis of a combined heating and cooling system model under different operating strategies
NASA Astrophysics Data System (ADS)
Dzierzgowski, Mieczysław; Zwierzchowski, Ryszard
2017-11-01
The paper presents an analysis of a combined heating and cooling system model under different operating strategies. Cooling demand for air conditioning purposes has grown steadily in Poland since the early 1990s. The main clients are large office buildings and shopping malls in downtown locations. Increased demand for heat in the summer would mitigate a number of problems regarding District Heating System (DHS) operation at minimum power, affecting the average annual price of heat (in summertime the share of costs related to transport losses is a strong cost factor). In the paper, computer simulations were performed for different supply network water temperature, assuming as input, real changes in the parameters of the DHS (heat demand, flow rates, etc.). On the basis of calculations and taking into account investment costs of the Absorption Refrigeration System (ARS) and the Thermal Energy Storage (TES) system, an optimal capacity of the TES system was proposed to ensure smooth and efficient operation of the District Heating Plant (DHP). Application of ARS with the TES system in the DHS in question increases net profit by 19.4%, reducing the cooling price for consumers by 40%.
Energy Sources and Systems Analysis: 40 South Lincoln Redevelopment District (Full Report)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2011-08-01
This report presents the results of a case study to analyze district energy systems for their potential use in a project that involves redeveloping 270 units of existing public housing, along with other nearby sites. When complete, the redevelopment project will encompass more than 900 mixed-income residential units, commercial and retail properties, and open space. The analysis estimated the hourly heating, cooling, domestic hot water, and electric loads required by the community; investigated potential district system technologies to meet those needs; and researched available fuel sources to power such systems.
NASA Astrophysics Data System (ADS)
Sant, T.; Buhagiar, D.; Farrugia, R. N.
2014-06-01
A new concept utilising floating wind turbines to exploit the low temperatures of deep sea water for space cooling in buildings is presented. The approach is based on offshore hydraulic wind turbines pumping pressurised deep sea water to a centralised plant consisting of a hydro-electric power system coupled to a large-scale sea water-cooled air conditioning (AC) unit of an urban district cooling network. In order to investigate the potential advantages of this new concept over conventional technologies, a simplified model for performance simulation of a vapour compression AC unit was applied independently to three different systems, with the AC unit operating with (1) a constant flow of sea surface water, (2) a constant flow of sea water consisting of a mixture of surface sea water and deep sea water delivered by a single offshore hydraulic wind turbine and (3) an intermittent flow of deep sea water pumped by a single offshore hydraulic wind turbine. The analysis was based on one year of wind and ambient temperature data for the Central Mediterranean that is known for its deep waters, warm climate and relatively low wind speeds. The study confirmed that while the present concept is less efficient than conventional turbines utilising grid-connected electrical generators, a significant portion of the losses associated with the hydraulic transmission through the pipeline are offset by the extraction of cool deep sea water which reduces the electricity consumption of urban air-conditioning units.
Cool & Dry: Dual-Path Approach for a Florida School.
ERIC Educational Resources Information Center
Khattar, Mukesh; Shirey, Don, III; Raustad, Richard
2003-01-01
Describes how the Brevard County School District in Florida teamed with companies EPRI and Florida Power and Light to implement a dual-path, low temperature air-distribution system used in conjunction with thermal energy storage. (EV)
Subcontracted activities related to TES for building heating and cooling
NASA Technical Reports Server (NTRS)
Martin, J.
1980-01-01
The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.
Energy Sources and Systems Analysis: 40 South Lincoln Redevelopment District (Short Report)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2011-08-01
This report presents the a brief overview of the results of a case study to analyze district energy systems for their potential use in a project that involves redeveloping 270 units of existing public housing, along with other nearby sites. When complete, the redevelopment project will encompass more than 900 mixed-income residential units, commercial and retail properties, and open space. The analysis estimated the hourly heating, cooling, domestic hot water, and electric loads required by the community; investigated potential district system technologies to meet those needs; and researched available fuel sources to power such systems. A full report of thismore » case study is also available.« less
Feasibility and Supply Analysis of U.S. Geothermal District Heating and Cooling System
NASA Astrophysics Data System (ADS)
He, Xiaoning
Geothermal energy is a globally distributed sustainable energy with the advantages of a stable base load energy production with a high capacity factor and zero SOx, CO, and particulates emissions. It can provide a potential solution to the depletion of fossil fuels and air pollution problems. The geothermal district heating and cooling system is one of the most common applications of geothermal energy, and consists of geothermal wells to provide hot water from a fractured geothermal reservoir, a surface energy distribution system for hot water transmission, and heating/cooling facilities to provide water and space heating as well as air conditioning for residential and commercial buildings. To gain wider recognition for the geothermal district heating and cooling (GDHC) system, the potential to develop such a system was evaluated in the western United States, and in the state of West Virginia. The geothermal resources were categorized into identified hydrothermal resources, undiscovered hydrothermal resources, near hydrothermal enhanced geothermal system (EGS), and deep EGS. Reservoir characteristics of the first three categories were estimated individually, and their thermal potential calculated. A cost model for such a system was developed for technical performance and economic analysis at each geothermally active location. A supply curve for the system was then developed, establishing the quantity and the cost of potential geothermal energy which can be used for the GDHC system. A West Virginia University (WVU) case study was performed to compare the competiveness of a geothermal energy system to the current steam based system. An Aspen Plus model was created to simulate the year-round campus heating and cooling scenario. Five cases of varying water flow rates and temperatures were simulated to find the lowest levelized cost of heat (LCOH) for the WVU case study. The model was then used to derive a levelized cost of heat as a function of the population density at a constant geothermal gradient. By use of such functions in West Virginia at a census tract level, the most promising census tracts in WV for the development of geothermal district heating and cooling systems were mapped. This study is unique in that its purpose was to utilize supply analyses for the GDHC systems and determine an appropriate economic assessment of the viability and sustainability of the systems. It was found that the market energy demand, production temperature, and project lifetime have negative effects on the levelized cost, while the drilling cost, discount rate, and capital cost have positive effects on the levelized cost by sensitivity analysis. Moreover, increasing the energy demand is the most effective way to decrease the levelized cost. The derived levelized cost function shows that for EGS based systems, the population density has a strong negative effect on the LCOH at any geothermal gradient, while the gradient only has a negative effect on the LCOH at a low population density.
Jylhä, Kirsti; Ruosteenoja, Kimmo; Jokisalo, Juha; Pilli-Sihvola, Karoliina; Kalamees, Targo; Mäkelä, Hanna; Hyvönen, Reijo; Drebs, Achim
2015-09-01
Dynamic building energy simulations need hourly weather data as input. The same high temporal resolution is required for assessments of future heating and cooling energy demand. The data presented in this article concern current typical values and estimated future changes in outdoor air temperature, wind speed, relative humidity and global, diffuse and normal solar radiation components. Simulated annual and seasonal delivered energy consumptions for heating of spaces, heating of ventilation supply air and cooling of spaces in the current and future climatic conditions are also presented for an example house, with district heating and a mechanical space cooling system. We provide details on how the synthetic future weather files were created and utilised as input data for dynamic building energy simulations by the IDA Indoor Climate and Energy program and also for calculations of heating and cooling degree-day sums. The information supplied here is related to the research article titled "Energy demand for the heating and cooling of residential houses in Finland in a changing climate" [1].
Design and optimization of geothermal power generation, heating, and cooling
NASA Astrophysics Data System (ADS)
Kanoglu, Mehmet
Most of the world's geothermal power plants have been built in 1970s and 1980s following 1973 oil crisis. Urgency to generate electricity from alternative energy sources and the fact that geothermal energy was essentially free adversely affected careful designs of plants which would maximize their performance for a given geothermal resource. There are, however, tremendous potentials to improve performance of many existing geothermal power plants by retrofitting, optimizing the operating conditions, re-selecting the most appropriate binary fluid in binary plants, and considering cogeneration such as a district heating and/or cooling system or a system to preheat water entering boilers in industrial facilities. In this dissertation, some representative geothermal resources and existing geothermal power plants in Nevada are investigated to show these potentials. Economic analysis of a typical geothermal resource shows that geothermal heating and cooling may generate up to 3 times as much revenue as power generation alone. A district heating/cooling system is designed for its incorporation into an existing 27 MW air-cooled binary geothermal power plant. The system as designed has the capability to meet the entire heating needs of an industrial park as well as 40% of its cooling needs, generating potential revenues of $14,040,000 per year. A study of the power plant shows that evaporative cooling can increase the power output by up to 29% in summer by decreasing the condenser temperature. The power output of the plant can be increased by 2.8 percent by optimizing the maximum pressure in the cycle. Also, replacing the existing working fluid isobutane by butane, R-114, isopentane, and pentane can increase the power output by up to 2.5 percent. Investigation of some well-known geothermal power generation technologies as alternatives to an existing 12.8 MW single-flash geothermal power plant shows that double-flash, binary, and combined flash/binary designs can increase the net power output by up to 31 percent, 35 percent, and 54 percent, respectively, at optimum operating conditions. An economic comparison of these designs appears to favor the combined flash/binary design, followed by the double-flash design.
NASA Astrophysics Data System (ADS)
Catchpole, Honza; Kouzmanov, Kalin; Bendezú, Aldo; Ovtcharova, Maria; Spikings, Richard; Stein, Holly; Fontboté, Lluís
2015-12-01
The Morococha district in central Peru is characterised by economically important Cordilleran polymetallic (Zn-Pb-Ag-Cu) vein and replacement bodies and the large Toromocho porphyry Cu-Mo deposit in its centre. U-Pb, Re-Os, and 40Ar/39Ar geochronology data for various porphyry-related hydrothermal mineralisation styles record a 3.5-Ma multi-stage history of magmatic-hydrothermal activity in the district. In the late Miocene, three individual magmatic-hydrothermal centres were active: the Codiciada, Toromocho, and Ticlio centres, each separated in time and space. The Codiciada centre is the oldest magmatic-hydrothermal system in the district and consists of a composite porphyry stock associated with anhydrous skarn and quartz-molybdenite veins. The hydrothermal events are recorded by a titanite U-Pb age at 9.3 ± 0.2 Ma and a molybdenite Re-Os age at 9.26 ± 0.03 Ma. These ages are indistinguishable from zircon U-Pb ages for porphyry intrusions of the composite stock and indicate a time span of 0.2 Ma for magmatic-hydrothermal activity. The small Ticlio magmatic-hydrothermal centre in the west of the district has a maximum duration of 0.3 Ma, ranging from porphyry emplacement to porphyry mineralisation at 8.04 ± 0.14 Ma (40Ar/39Ar muscovite cooling age). The Toromocho magmatic-hydrothermal centre has a minimum of five recorded porphyry intrusions that span a total of 1.3 Ma and is responsible for the formation of the giant Toromocho Cu-Mo deposit. At least two hydrothermal pulses are identified. Post-dating a first pulse of molybdenite mineralisation, wide-spread hydrous skarn covers an area of over 6 km2 and is recorded by five 40Ar/39Ar cooling ages at 7.2-6.8 Ma. These ages mark the end of the slowly cooling and long-lived Toromocho magmatic-hydrothermal centre soon after last magmatic activity at 7.26 ± 0.02 Ma. District-wide (50 km2) Cordilleran base metal vein and replacement bodies post-date the youngest recorded porphyry mineralisation event at Toromocho by more than 0.5 Ma. Polymetallic veins (5.78 ± 0.10 and 5.72 ± 0.18 Ma; 40Ar/39Ar ages) and the Manto Italia polymetallic replacement bodies (6.23 ± 0.12 and 6.0 ± 0.2 Ma; 40Ar/39Ar ages) are interpreted to have been formed by a single hydrothermal pulse. Hydrothermal activity ceased after the formation of the base metal vein and replacement bodies. Overlapping monazite U-Pb (8.26 ± 0.18 Ma) and muscovite 40Ar/39Ar ages (8.1 ± 0.5 Ma) from the early base metal stage of one Cordilleran vein sample in the Sulfurosa area provide evidence that a discrete hydrothermal pulse was responsible for polymetallic vein formation 2.6 Ma prior to the district-wide polymetallic veins. These ages pre-date those of Toromocho porphyry Cu-Mo formation and show that Zn-Pb-Ag-Cu mineralisation formed during several discrete magmatic-hydrothermal pulses in the same district.
CASTILLA, J.; BARRICARTE, A.; ALDAZ, J.; GARCÍA CENOZ, M.; FERRER, T.; PELAZ, C.; PINEDA, S.; BALADRÓN, B.; MARTÍN, I.; GOÑI, B.; ARATAJO, P.; CHAMORRO, J.; LAMEIRO, F.; TORROBA, L.; DORRONSORO, I.; MARTÍNEZ-ARTOLA, V.; ESPARZA, M. J.; GASTAMINZA, M. A.; FRAILE, P.; ALDAZ, P.
2008-01-01
SUMMARY An outbreak of Legionnaire's disease was detected in Pamplona, Spain, on 1 June 2006. Patients with pneumonia were tested to detect Legionella pneumophila antigen in urine (Binax Now; Binax Inc., Scarborough, ME, USA), and all 146 confirmed cases were interviewed. The outbreak was related to district 2 (22 012 inhabitants), where 45% of the cases lived and 50% had visited; 5% lived in neighbouring districts. The highest incidence was found in the resident population of district 2 (3/1000 inhabitants), section 2 (14/1000). All 31 cooling towers of district 2 were analysed. L. pneumophila antigen (Binax Now) was detected in four towers, which were closed on 2 June. Only the strain isolated in a tower situated in section 2 of district 2 matched all five clinical isolates, as assessed by mAb and two genotyping methods, AFLP and PFGE. Eight days after closing the towers, new cases ceased appearing. Early detection and rapid coordinated medical and environmental actions permitted immediate control of the outbreak and probably contributed to the null case fatality. PMID:17662166
Castilla, J; Barricarte, A; Aldaz, J; García Cenoz, M; Ferrer, T; Pelaz, C; Pineda, S; Baladrón, B; Martín, I; Goñi, B; Aratajo, P; Chamorro, J; Lameiro, F; Torroba, L; Dorronsoro, I; Martínez-Artola, V; Esparza, M J; Gastaminza, M A; Fraile, P; Aldaz, P
2008-06-01
An outbreak of Legionnaire's disease was detected in Pamplona, Spain, on 1 June 2006. Patients with pneumonia were tested to detect Legionella pneumophila antigen in urine (Binax Now; Binax Inc., Scarborough, ME, USA), and all 146 confirmed cases were interviewed. The outbreak was related to district 2 (22 012 inhabitants), where 45% of the cases lived and 50% had visited; 5% lived in neighbouring districts. The highest incidence was found in the resident population of district 2 (3/1000 inhabitants), section 2 (14/1000). All 31 cooling towers of district 2 were analysed. L. pneumophila antigen (Binax Now) was detected in four towers, which were closed on 2 June. Only the strain isolated in a tower situated in section 2 of district 2 matched all five clinical isolates, as assessed by mAb and two genotyping methods, AFLP and PFGE. Eight days after closing the towers, new cases ceased appearing. Early detection and rapid coordinated medical and environmental actions permitted immediate control of the outbreak and probably contributed to the null case fatality.
NREL Partners with California to Accelerate Advanced Energy Communities |
, heating, and or cooling Smart energy management systems for residential, commercial and industrial the residences, commercial and industrial buildings. Visit the NREL website to learn about how NREL's efficiency of both residential and commercial buildings, communities, and districts. -Linh Truong Mission
Mix up the Indian with All the Patwa: Rajamuffin Sounds in "Cool" Britannia
ERIC Educational Resources Information Center
Cooper, Carolyn
2004-01-01
Apache Indian's spectacular performance of the identity of "Jamaican" dancehall DJ exemplifies the problematic politics of acculturation in "postcolonial" Britain. Born in the Handsworth district of Birmingham, a major centre of Caribbean and South Asian migration, this multilingual, border-crossing, urban youth appropriates…
Multi-purpose rainwater harvesting for water resource recovery and the cooling effect.
An, Kyoung Jin; Lam, Yun Fat; Hao, Song; Morakinyo, Tobi Eniolu; Furumai, Hiroaki
2015-12-01
The potential use of rainwater harvesting in conjunction with miscellaneous water supplies and a rooftop garden with rainwater harvesting facility for temperature reduction have been evaluated in this study for Hong Kong. Various water applications such as toilet flushing and areal climate controls have been systematically considered depending on the availability of seawater toilet flushing using the Geographic Information System (GIS). For water supplies, the district Area Precipitation per Demand Ratio (APDR) has been calculated to quantify the rainwater utilization potential of each administrative district in Hong Kong. Districts with freshwater toilet flushing prove to have higher potential for rainwater harvest and utilization compared to the areas with seawater toilet flushing. Furthermore, the effectiveness of using rainwater harvesting for miscellaneous water supplies in Hong Kong and Tokyo has been analyzed and compared; this revives serious consideration of diurnal and seasonal patterns of rainfall in applying such technology. In terms of the cooling effect, the implementation of a rooftop rainwater harvesting garden has been evaluated using the ENVI-met model. Our results show that a temperature drop of 1.3 °C has been observed due to the rainwater layer in the rain garden. This study provides valuable insight into the applicability of the rainwater harvesting for sustainable water management practice in a highly urbanized city. Copyright © 2015 Elsevier Ltd. All rights reserved.
Building Modelling Methodologies for Virtual District Heating and Cooling Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saurav, Kumar; Choudhury, Anamitra R.; Chandan, Vikas
District heating and cooling systems (DHC) are a proven energy solution that has been deployed for many years in a growing number of urban areas worldwide. They comprise a variety of technologies that seek to develop synergies between the production and supply of heat, cooling, domestic hot water and electricity. Although the benefits of DHC systems are significant and have been widely acclaimed, yet the full potential of modern DHC systems remains largely untapped. There are several opportunities for development of energy efficient DHC systems, which will enable the effective exploitation of alternative renewable resources, waste heat recovery, etc., inmore » order to increase the overall efficiency and facilitate the transition towards the next generation of DHC systems. This motivated the need for modelling these complex systems. Large-scale modelling of DHC-networks is challenging, as it has several components interacting with each other. In this paper we present two building methodologies to model the consumer buildings. These models will be further integrated with network model and the control system layer to create a virtual test bed for the entire DHC system. The model is validated using data collected from a real life DHC system located at Lulea, a city on the coast of northern Sweden. The test bed will be then used for simulating various test cases such as peak energy reduction, overall demand reduction etc.« less
Weather. Third Grade. Revised. Anchorage School District Elementary Science Program.
ERIC Educational Resources Information Center
Defendorf, Jean, Ed.
This resource book introduces third-grade children to the environment by studying the weather and its effects. Lessons are provided including: (1) constructing a weather diary; (2) thermometers; (3) clouds; (4) barometric pressure; (5) wind vanes; (6) heating and cooling air; and (7) analyzing weather data. Each lesson includes a listing of…
DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhattacharya, Saptarshi; Chandan, Vikas; Arya, Vijay
In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models ofmore » individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.« less
Rowan, E.L.; Leach, D.L.
1989-01-01
Homogenization temperatures and freezing point depressions were determined for fluid inclusions in Bonneterre Dolomite-hosted dolomite cements in mine samples, as well as drill core from up to 13 km outside of the district. A well-defined cathodoluminescent zonation distinguishes dolomite growth zones as older or younger than main-stage mineralization. Homogenization temperatures and salinities in samples from mines are not systematically different from those of samples outside of the district. The absence of a significant, recognizable decrease in temperature either vertically within the section or east-west across the district, coupled with the minor amount of silica in the district, argues against cooling as a primary cause of sulfide precipitation. In a reduced sulfur mineralization model with Pb carried as chloride complexes, dilution is also a possible sulfide precipitation mechanism. The difference in Pb solubility in the extremes of the chloride concentration range, 3.9 vs. 5.9 molal, reaches 1 ppm only for pH values below approximately 4.5. The distribution of warm inclusions beyond the Viburnum Trend district implies that fluid migration was regional in scale. Elevated temperatures observed in fluid inclusions at shallow stratigraphic depths are consistent with a gravity flow hydrologic system characterized by rapid flow rates and the capacity for advective heat transport. -from Authors
Cool Science: K-12 Climate Change Art Displayed on Buses
NASA Astrophysics Data System (ADS)
Chen, R. F.; Lustick, D. S.; Lohmeier, J.; Thompson, S. R.
2015-12-01
Cool science is an art contest where K12 students create placards (7" x 22") to educate the public about climate change. Students are prompted to create their artwork in response to questions such as: What is the evidence for climate change? How does climate change impact your local community? What can you do to reduce the impacts of climate change? In each of three years, 500-600 student entrees have been submitted from more than 12 school districts across Massachusetts. A panel of judges including scientists, artists, rapid transit representatives, and educators chooses elementary, middle, and high school winners. Winners (6), runners-up (6), and honorable mentions (12) and their families and teachers are invited to an annual Cool Science Award Ceremony to be recognized and view winning artwork. All winning artwork is posted on the Cool Science website. The winning artwork (2 per grade band) is converted into placards (11" x 28") and posters (2.5' x 12') that are placed on the inside (placards) and outside (posters) of buses. Posters are displayed for one month. So far, Cool Science was implemented in Lowell, MA where over 5000 public viewers see the posters daily on the sides of Lowell Rapid Transit Authority (LRTA) buses, making approximately 1,000,000 impressions per year. Cool Science acts to increase climate literacy in children as well as the public, and as such promotes intergenerational learning. Using art in conjunction with science learning about climate change appears to be effective at engaging not just traditionally high achieving science students, but also those interested in the creative arts. Hearing winners' stories about how they created their artwork and what this contest meant to them supports the idea that Cool Science attracts a wide diversity of students. Parents discuss climate change with their children. Multiple press releases announcing the winners further promotes the awareness of climate change throughout school districts and their communities. Pre- and post-surveys of LRTA riders suggests that public viewers of winning artwork increase their awareness that climate change is happening, that climate change is human caused, and that they want to learn more. Using student voices (artwork) appears to be an effective way to communicate climate change issues to public audiences.
Applications and challenges for thermal energy storage
NASA Astrophysics Data System (ADS)
Kannberg, L. D.; Tomlinson, J. T.
1991-04-01
New thermal energy storage (TES) technologies are being developed and applied as society strives to relieve increasing energy and environmental stresses. Applications for these new technologies range from residential and district heating and cooling using waste and solar energy, to high-temperature energy storage for power production and industrial processes. In the last two decades there has been great interest and development of heat storage systems, primarily for residential and commercial buildings. While development has continued, the rate of advancement has slowed with current technology considered adequate for electrically charged heat storage furnaces. Use of chill storage for building diurnal cooling has received substantial development.
Commercial Buildings Energy Consumption Survey 2012 - Detailed Tables
2016-01-01
The 2012 CBECS consumption and expenditures detailed tables are comprised of Tables C1-C38, which cover overall electricity, natural gas, fuel oil and district heat consumption, and tables E1-E11, which disaggregate the same energy sources by end use (heating, cooling, lighting, etc.). All of the detailed tables contain extensive row categories of building characteristics.
Cool Science: Using Children's Art to Communicate Climate Change (Invited)
NASA Astrophysics Data System (ADS)
Lustick, D. S.; Lohmeier, J.; Chen, R. F.
2013-12-01
Cool Science is a K-12 Climate Change Science Art Competition. Working with teachers, parents, and students, the project aims to identify outstanding works of art by students about climate change and display the art throughout public mass transit. Cool Science has three distinct goals: 1) provide a convenient means for art and science teachers to incorporate climate change into their curriculum, 2) support teacher/student learning about climate change science, and 3) foster informal learning about climate change among people riding mass transit. By efficiently connecting formal and informal learning with one project, Cool Science is an innovative project that expands the way we engage and evaluate students. Using children's artwork to communicate complex scientific issues such as climate change is a powerful learning experience for the artist, teacher, and audience. Last year, Cool Science received nearly 600 entries from students representing 36 teachers from 32 school districts. Six winning entries went on public display with one highlighted each month from January through June. In addition, there were 6 Runner Ups and 12 Honorable Mentions. For the winning students, it is an unforgettable experience to see a nine-foot version of their artwork traveling around the streets on the side of a bus!
Heat-pump-centered integrated community energy systems: System development summary
NASA Astrophysics Data System (ADS)
Calm, J. M.
1980-02-01
An introduction to district heating systems employing heat pumps to enable use of low temperature energy sources is presented. These systems operate as thermal utilities to provide space heating and may also supply space cooling, service water heating, and other thermal services. Otherwise wasted heat from industrial and commercial processes, natural sources including solar and geothermal heat, and heat stored on an annual cycle from summer cooling may be effectively utilized by the systems described. More than one quarter of the energy consumed in the United States is used to heat and cool buildings and to heat service water. Natural gas and oil provide approximately 83% of this energy. The systems described show potential to reduce net energy consumption for these services by 20 to 50% and to allow fuel substitution with less scarce resources not practical in smaller, individual building systems. Seven studies performed for the system development phase are summarized.
Risk perception of heat waves and its spatial variation in Nanjing, China
NASA Astrophysics Data System (ADS)
Huang, Lei; Yang, Qianqi; Li, Jie; Chen, Jin; He, Ruoying; Zhang, Can; Chen, Kai; Dong, Steven Guanpeng; Liu, Yang
2018-05-01
The intensity, frequency, and duration of heat waves are expected to increase with climate change. In this study, we found a significant difference of public perceived effects of heat waves and trust in government among urban, suburban, and rural districts. Rural residents had a significant higher effect perception than urbanites and also showed stronger willingness to have medical insurance or regular physical examinations. Meanwhile, suburban residents had the lowest trust perception in government among these three districts, which may be due to suburban districts' unique social structure and complex social issues. Besides, we assessed the relationship between the factor effect and demographic variables. The results showed that urban respondents' effect perception was significantly related to heat wave experiences. Suburban respondents' effect perception was significantly related to age, income, and heat wave experiences. And rural respondents' effect perception was significantly related to income and chronic diseases. Based on our results, much more attention needs to be paid to rural districts. The government should strengthen infrastructure construction such as cooling centers, improve emergency response plans and mechanisms, and increase reserves of emergency supplies in rural districts. Also, targeted risk communication is of the equal importance to aid the policy-makers improving the relationship with the public and regaining the public's trust and support.
Risk perception of heat waves and its spatial variation in Nanjing, China.
Huang, Lei; Yang, Qianqi; Li, Jie; Chen, Jin; He, Ruoying; Zhang, Can; Chen, Kai; Dong, Steven Guanpeng; Liu, Yang
2018-05-01
The intensity, frequency, and duration of heat waves are expected to increase with climate change. In this study, we found a significant difference of public perceived effects of heat waves and trust in government among urban, suburban, and rural districts. Rural residents had a significant higher effect perception than urbanites and also showed stronger willingness to have medical insurance or regular physical examinations. Meanwhile, suburban residents had the lowest trust perception in government among these three districts, which may be due to suburban districts' unique social structure and complex social issues. Besides, we assessed the relationship between the factor effect and demographic variables. The results showed that urban respondents' effect perception was significantly related to heat wave experiences. Suburban respondents' effect perception was significantly related to age, income, and heat wave experiences. And rural respondents' effect perception was significantly related to income and chronic diseases. Based on our results, much more attention needs to be paid to rural districts. The government should strengthen infrastructure construction such as cooling centers, improve emergency response plans and mechanisms, and increase reserves of emergency supplies in rural districts. Also, targeted risk communication is of the equal importance to aid the policy-makers improving the relationship with the public and regaining the public's trust and support.
Risk perception of heat waves and its spatial variation in Nanjing, China
NASA Astrophysics Data System (ADS)
Huang, Lei; Yang, Qianqi; Li, Jie; Chen, Jin; He, Ruoying; Zhang, Can; Chen, Kai; Dong, Steven Guanpeng; Liu, Yang
2017-12-01
The intensity, frequency, and duration of heat waves are expected to increase with climate change. In this study, we found a significant difference of public perceived effects of heat waves and trust in government among urban, suburban, and rural districts. Rural residents had a significant higher effect perception than urbanites and also showed stronger willingness to have medical insurance or regular physical examinations. Meanwhile, suburban residents had the lowest trust perception in government among these three districts, which may be due to suburban districts' unique social structure and complex social issues. Besides, we assessed the relationship between the factor effect and demographic variables. The results showed that urban respondents' effect perception was significantly related to heat wave experiences. Suburban respondents' effect perception was significantly related to age, income, and heat wave experiences. And rural respondents' effect perception was significantly related to income and chronic diseases. Based on our results, much more attention needs to be paid to rural districts. The government should strengthen infrastructure construction such as cooling centers, improve emergency response plans and mechanisms, and increase reserves of emergency supplies in rural districts. Also, targeted risk communication is of the equal importance to aid the policy-makers improving the relationship with the public and regaining the public's trust and support.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-01-31
This volume contains the backup data for the portion of the load and service assessment in Section 2, Volume II of this report. This includes: locations of industrial and commercial establishments, locations of high rise buildings, data from the Newark (Essex County) Directory of Business, data from the Hudson County Industrial Directory, data from the N. J. Department of Energy Inventory of Public Buildings, data on commercial and industrial establishments and new developments in the Hackensack Meadowlands, data on urban redevelopment and Operation Breakthrough, and list of streets in the potential district heating areas of Newark/Harrison and Jersey City/Hoboken.
Project financing of district heating/cooling systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feldman, R.D.
1986-03-01
Two issues are discussed in detail: the project finance joint venture and technology transfers. An increase if the frequency of these issues has been served in project financings. An understanding of these issues is necessary to structure project financings of alternate energy projects in the future. Capitalization needs are outlined, and typical provisions of a joint finance structure are outlined. The issue of exclusivity as it applies to technology transfers is discussed.
NASA Astrophysics Data System (ADS)
Andre, Konrad; Zuvela-Aloise, Maja; Lettmayer, Gudrun; Schwaiger, Hannes Peter; Kaltenegger, Ingrid; Bird, David Neil; Woess-Gallasch, Susanne
2017-04-01
The phenomenon of Urban Heat Islands (UHIs) observed in cities, caused by changes in energy balance due to the structural development of the city as well as by sealed surfaces and a lack of vegetation, is expected to strengthen in the future and will further contribute to heat stress, creating an increased need for energy for cooling and ventilation as well as lowering human comfort. Due to a changing climate, rising heat stress, pronounced by an increased intensity or frequency of heat waves, could have far reaching implications for major Austrian cities in the near future. Simultaneous to this expected increasing of the already existing UHI-effect, it is observable, that continuous densification of the core parts of cities is being intensified through implemented traditional urban planning measures. This is particular relevant for high densely populated districts of the city. Several possible counteractions how to address this challenge are already known, partly investigated in urban modeling studies on the effects of modifying the reflective properties of buildings and urban areas for the city of Vienna. On this experience, within the Austrian FFG and KLIEN Smart Cities project JACKY COOL CHECK (Project Nr. 855554), a wide set of measures to reduce heat stress, consisting of e.g. unsealed surfaces, green areas, green roofs, improve reflective properties of different surfaces etc., for the densely built-up residential and business district of Jakomini in the city of Graz/Styria is investigated, to gain decisive data pointing out the peculiarities of UHIs and the potential cooling effects of these target measures for this local specific area. These results serving as a basis for the selection of sustainable measures that will be implemented, in coordination with local stakeholders and considering their interests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saurav, Kumar; Chandan, Vikas
District-heating-and-cooling (DHC) systems are a proven energy solution that has been deployed for many years in a growing number of urban areas worldwide. They comprise a variety of technologies that seek to develop synergies between the production and supply of heat, cooling, domestic hot water and electricity. Although the benefits of DHC systems are significant and have been widely acclaimed, yet the full potential of modern DHC systems remains largely untapped. There are several opportunities for development of energy efficient DHC systems, which will enable the effective exploitation of alternative renewable resources, waste heat recovery, etc., in order to increasemore » the overall efficiency and facilitate the transition towards the next generation of DHC systems. This motivated the need for modelling these complex systems. Large-scale modelling of DHC-networks is challenging, as it has several components such as buildings, pipes, valves, heating source, etc., interacting with each other. In this paper, we focus on building modelling. In particular, we present a gray-box methodology for thermal modelling of buildings. Gray-box modelling is a hybrid of data driven and physics based models where, coefficients of the equations from physics based models are learned using data. This approach allows us to capture the dynamics of the buildings more effectively as compared to pure data driven approach. Additionally, this approach results in a simpler models as compared to pure physics based models. We first develop the individual components of the building such as temperature evolution, flow controller, etc. These individual models are then integrated in to the complete gray-box model for the building. The model is validated using data collected from one of the buildings at Lule{\\aa}, a city on the coast of northern Sweden.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, Kody M.; Kim, Jong Suk; Cole, Wesley J.
2016-10-01
District energy systems can produce low-cost utilities for large energy networks, but can also be a resource for the electric grid by their ability to ramp production or to store thermal energy by responding to real-time market signals. In this work, dynamic optimization exploits the flexibility of thermal energy storage by determining optimal times to store and extract excess energy. This concept is applied to a polygeneration distributed energy system with combined heat and power, district heating, district cooling, and chilled water thermal energy storage. The system is a university campus responsible for meeting the energy needs of tens ofmore » thousands of people. The objective for the dynamic optimization problem is to minimize cost over a 24-h period while meeting multiple loads in real time. The paper presents a novel algorithm to solve this dynamic optimization problem with energy storage by decomposing the problem into multiple static mixed-integer nonlinear programming (MINLP) problems. Another innovative feature of this work is the study of a large, complex energy network which includes the interrelations of a wide variety of energy technologies. Results indicate that a cost savings of 16.5% is realized when the system can participate in the wholesale electricity market.« less
A Tale of Three District Energy Systems: Metrics and Future Opportunities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pass, Rebecca Zarin; Wetter, Michael; Piette, Mary Ann
Improving the sustainability of cities is crucial for meeting climate goals in the next several decades. One way this is being tackled is through innovation in district energy systems, which can take advantage of local resources and economies of scale to improve the performance of whole neighborhoods in ways infeasible for individual buildings. These systems vary in physical size, end use services, primary energy resources, and sophistication of control. They also vary enormously in their choice of optimization metrics while all under the umbrella-goal of improved sustainability. This paper explores the implications of choice of metric on district energy systemsmore » using three case studies: Stanford University, the University of California at Merced, and the Richmond Bay campus of the University of California at Berkeley. They each have a centralized authority to implement large-scale projects quickly, while maintaining data records, which makes them relatively effective at achieving their respective goals. Comparing the systems using several common energy metrics reveals significant differences in relative system merit. Additionally, a novel bidirectional heating and cooling system is presented. This system is highly energy-efficient, and while more analysis is required, may be the basis of the next generation of district energy systems.« less
NASA Astrophysics Data System (ADS)
Arkadyev, B. A.
2015-10-01
Basic principles of cooling of high-temperature steam turbines and constructive solutions used for development of the world's first cooled steam turbine SKR-100 (R-100-300) are described. Principal differences between the thermodynamic properties of cooling medium in the steam and gas turbines and the preference of making flow passes of cooled cylinders of steam turbines as reactive are shown. Some of its operation results and their conclusions are given. This turbine with a power of 100 MW, initial steam parameters approximately 30 MPa and 650°C, and back pressure 3 MPa was made by a Kharkov turbine plant in 1961 and ran successfully at a Kashira GRES (state district power plant) up to 1979, when it was taken out of use in a still fully operating condition. For comparison, some data on construction features and operation results of the super-high pressure cylinder of steam turbines of American Philo 6 (made by General Electric Co.) and Eddystone 1 (made by Westinghouse Co.) power generating units, which are close to the SKR-100 turbine by design initial steam parameters and the implementation time, are given. The high operational reliability and effectiveness of the cooling system that was used in the super-high pressure cylinder of the SKR-100 turbine of the power-generating unit, which were demonstrated in operation, confirms rightfulness and expediency of principles and constructive solutions laid at its development. As process steam temperatures are increased, the realization of the proposed approach to cooling of multistage turbines makes it possible to limit for large turbine parts the application of new, more expensive high-temperature materials, which are required for making steam boilers, and, in some cases, to do completely away with their utilization.
Long-range forecasts for the energy market - a case study
NASA Astrophysics Data System (ADS)
Hyvärinen, Otto; Mäkelä, Antti; Kämäräinen, Matti; Gregow, Hilppa
2017-04-01
We examined the feasibility of long-range forecasts of temperature for needs of the energy sector in Helsinki, Finland. The work was done jointly by Finnish Meteorological Institute (FMI) and Helen Ltd, the main Helsinki metropolitan area energy provider, and especially provider of district heating and cooling. Because temperatures govern the need of heating and cooling and, therefore, the energy demand, better long-range forecasts of temperature would be highly useful for Helen Ltd. Heating degree day (HDD) is a parameter that indicates the demand of energy to heat a building. We examined the forecasted monthly HDD values for Helsinki using UK Met Office seasonal forecasts with the lead time up to two months. The long-range forecasts of monthly HDD showed some skill in Helsinki in winter 2015-2016, especially if the very cold January is excluded.
The nature of the fluids associated with the Monte Rosa gold district, NW Alps, Italy
NASA Astrophysics Data System (ADS)
Lattanzi, P.
1990-12-01
Recent O-isotope and fluid inclusion studies have provided evidence on the nature of the fluids associated with the late-Alpine quartz-gold deposits of the Monte Rosa district. The most abundant inclusions in quartz from these deposits contain a low salinity aqueous fluid (about 2% to 10% wt. NaCl eq.), and a CO2 phase (usually less than 20% mol), in places with minor methane. CO2 densities and total homogenization temperatures vary widely throughout the district, reflecting diverse conditions of trapping (P = 1 to 3 kb, T = 300° to 450°C). At Miniera dei Cani, unmixing between CO2-rich and H2O-rich fluids possibly occurred. A second type of inclusion contains an aqueous brine without recognizable CO2, and is especially abundant at Val Toppa. O-isotope studies suggest that fluids were largely equilibrated in a metamorphic environment. It is concluded that the gold-related fluids in the district were mainly of a metamorphic nature; at Val Toppa, both isotopic and fluid inclusion data point to contributions of unexchanged meteoric waters. Mechanisms of gold transport and precipitation are less contrained. A possible model involves transport of gold as bisulfide complexes, and precipitation due to one or more of the following processes: decrease of sulfur activity due to precipitation of sulfides, wall-rock reaction, cooling/dilution, and/or fluid unmixing.
Seasonal Thermal Energy Storage Program
NASA Technical Reports Server (NTRS)
Minor, J. E.
1980-01-01
The Seasonal Thermal Energy Storage (STES) Program designed to demonstrate the storage and retrieval of energy on a seasonal basis using heat or cold available from waste or other sources during a surplus period is described. Factors considered include reduction of peak period demand and electric utility load problems and establishment of favorable economics for district heating and cooling systems for commercialization of the technology. The initial thrust of the STES Program toward utilization of ground water systems (aquifers) for thermal energy storage is emphasized.
NASA Astrophysics Data System (ADS)
Ettler, Vojtěch; Johan, Zdenek; Touray, Jean-Claude; Jelínek, Emil
2000-08-01
Metallurgical slags of different ages resulting from Pb-metallurgy in the Příbram district (Czech Republic) have been studied. The chemical analysis (EPMA) of melilite, clinopyroxene, olivine and glassy matrix showed the following ZnO concentrations (in wt. %): 3.20-11.93 (melilite), 1.56 (clinopyroxene), 1.29-7.82 (olivine), 1.58-6.58 (glass). The Zn partition coefficient D = Cs / Cl between crystallized phases and coexisting glass was calculated. The values obtained are: 1.96-2.16 (melilite), 0.41 (clinopyroxene) and 0.79-1.19 (olivine). The distribution of zinc between the crystalline phases and glass depends on the phase assemblage, which reflects the blast furnace charge and temperature, as well as the cooling conditions of slags.
A feasibility study on solar utility total energy system /SUTES/
NASA Astrophysics Data System (ADS)
Bilgen, E.
1980-11-01
A fully dedicated central receiver solar utility (CRSU) designed to meet domestic energy requirements for space heating and hot water has been synthesized and assessed at the conceptual level. The solar utility total energy system (SUTES) integrates (1) a central receiver solar utility (CRSU), (2) an electrical power generating system (EPGS), (3) a hydrogen production plant (HPP), (4) a water chilling system for cooling, heat pump system (HPS), (5) necessary thermal energy storage systems (TES), (6) a district heating and cooling system (DH&CS). All subsystems are close-coupled. Using consistent costing bases, it has been found that the SUTES concept provides energy costs which are lower than those provided by a CRSU. Representative costs are $3.14/GJ versus $8.56/GJ for 10 percent recovery factor and $12.55/GJ versus $13.47/GJ for 17.5 percent recovery factor.
Solar Absorption Refrigeration System for Air-Conditioning of a Classroom Building in Northern India
NASA Astrophysics Data System (ADS)
Agrawal, Tanmay; Varun; Kumar, Anoop
2015-10-01
Air-conditioning is a basic tool to provide human thermal comfort in a building space. The primary aim of the present work is to design an air-conditioning system based on vapour absorption cycle that utilizes a renewable energy source for its operation. The building under consideration is a classroom of dimensions 18.5 m × 13 m × 4.5 m located in Hamirpur district of Himachal Pradesh in India. For this purpose, cooling load of the building was calculated first by using cooling load temperature difference method to estimate cooling capacity of the air-conditioning system. Coefficient of performance of the refrigeration system was computed for various values of strong and weak solution concentration. In this work, a solar collector is also designed to provide required amount of heat energy by the absorption system. This heat energy is taken from solar energy which makes this system eco-friendly and sustainable. A computer program was written in MATLAB to calculate the design parameters. Results were obtained for various values of solution concentrations throughout the year. Cost analysis has also been carried out to compare absorption refrigeration system with conventional vapour compression cycle based air-conditioners.
Energy efficiency in waste-to-energy and its relevance with regard to climate control.
Ragossnig, Arne M; Wartha, Christian; Kirchner, Andreas
2008-02-01
This article focuses on systematically highlighting the ways to optimize waste-to-energy plants in terms of their energy efficiency as an indicator of the positive effect with regard to climate control. Potentials for increasing energy efficiency are identified and grouped into categories. The measures mentioned are illustrated by real-world examples. As an example, district cooling as a means for increasing energy efficiency in the district heating network of Vienna is described. Furthermore a scenario analysis shows the relevance of energy efficiency in waste management scenarios based on thermal treatment of waste with regard to climate control. The description is based on a model that comprises all relevant processes from the collection and transportation up to the thermal treatment of waste. The model has been applied for household-like commercial waste. The alternatives compared are a combined heat and power incinerator, which is being introduced in many places as an industrial utility boiler or in metropolitan areas where there is a demand for district heating and a classical municipal solid waste incinerator producing solely electrical power. For comparative purposes a direct landfilling scenario has been included in the scenario analysis. It is shown that the energy efficiency of thermal treatment facilities is crucial to the quantity of greenhouse gases emitted.
Webber, Karen L.; Simmons, William B.; Falster, Alexander U.; Foord, Eugene E.
1999-01-01
Pegmatites of the Pala and Mesa Grande Pegmatite Districts, San Diego County, California are typically thin, sheet-like composite pegmatite-aplite dikes. Aplitic portions of many dikes display pronounced mineralogical layering referred to as "line rock," characterized by fine-grained, garnet-rich bands alternating with albite- and quartz-rich bands. Thermal modeling was performed for four dikes in San Diego County including the 1 m thick Himalaya dike, the 2 m thick Mission dike, the 8 m thick George Ashley dike, and the 25 m thick Stewart dike. Calculations were based on conductive cooling equations accounting for latent heat of crystallization, a melt emplacement temperature of 650 °C into 150 °C fractured, gabbroic country rock at a depth of 5 km, and an estimated 3 wt% initial H2O content in the melt. Cooling to -5 cm/s. Crystal size distribution (CSD) studies of garnet from layered aplites suggest growth rates of about 10-6 cm/s. These results indicate that the dikes cooled and crystallized rapidly, with variable nucleation rates but high overall crystal-growth rates. Initial high nucleation rates coincident with emplacement and strong undercooling can account for the millimeter-size aplite grains. Lower nucleation rates coupled with high growth rates can explain the decimeter-size minerals in the hanging walls, cores, and miarolitic cavities of the pegmatites. The presence of tourmaline and/or lepidolite throughout these dikes suggests that although the melts were initially H2O-undersaturated, high melt concentrations of incompatible (or fluxing) components such as B, F, and Li (±H2O), aided in the development of large pegmatitic crystals that grew rapidly in the short times suggested by the conductive cooling models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Labrousse, M.; Lerouge, B.; Dupuy, G.
1978-04-01
THERMOS is a water reactor designed to provide hot water up to 120/sup 0/C for district heating or for desalination applications. It is a 100-MW reactor based on proven technology: oxide fuel plate elements, integrated primary circuit, and reactor vessel located in the bottom of a pool. As in swimming pool reactors, the pool is used for biological shielding, emergency core cooling, and fission product filtering (in case of an accident). Before economics, safety is the main characteristic of the concept: no fuel failure admitted, core under water in any accidental configuration, inspection of every ''nuclear'' component, and double-wall containment.
Ice/water slurry blocking phenomenon at a tube orifice.
Hirochi, Takero; Yamada, Shuichi; Shintate, Tuyoshi; Shirakashi, Masataka
2002-10-01
The phenomenon of ice-particle/water mixture blocking flow through a pipeline is a problem that needs to be solved before mixture flow can be applied for practical use in cold energy transportation in a district cooling system. In this work, the blocking mechanism of ice-particle slurry at a tube orifice is investigated and a criterion for blocking is presented. The cohesive nature of ice particles is shown to cause compressed plug type blocking and the compressive yield stress of a particle cluster is presented as a measure for the cohesion strength of ice particles.
Proceedings of the Alternate Energy Systems Seminar
NASA Technical Reports Server (NTRS)
1978-01-01
The Alternative Energy Systems Seminar was held on March 30, 1978, and was sponsored jointly be the Southwest District Office of the U.S. Department of Energy and JPL. The seminar was an experiment in information exchange with the aim of presenting, in a single day, status and prospects for a number of advanced energy systems to a diverse, largely nontechnical audience, and to solicit post-seminar responses from that audience as to the seminar's usefulness. The major systems presented are: (1) Solar Photovoltaic; (2) Geothermal; (3) Cogeneration Power; (4) Solar Thermal; (5) Solar Heating and Cooling; (6) Wind Energy; and (7) Systems Considerations.
NASA Astrophysics Data System (ADS)
Xu, Xiaoyu; Chen, Fei; Shen, Shuanghe; Miao, Shiguang; Barlage, Michael; Guo, Wenli; Mahalov, Alex
2018-03-01
The air conditioning (AC) electric loads and their impacts on local weather over Beijing during a 5 day heat wave event in 2010 are investigated by using the Weather Research and Forecasting (WRF) model, in which the Noah land surface model with multiparameterization options (Noah-MP) is coupled to the multilayer Building Effect Parameterization and Building Energy Model (BEP+BEM). Compared to the legacy Noah scheme coupled to BEP+BEM, this modeling system shows a better performance, decreasing the root-mean-square error of 2 m air temperature to 1.9°C for urban stations. The simulated AC electric loads in suburban and rural districts are significantly improved by introducing the urban class-dependent building cooled fraction. Analysis reveals that the observed AC electric loads in each district are characterized by a common double peak at 3 p.m. and at 9 p.m. local standard time, and the incorporation of more realistic AC working schedules helps reproduce the evening peak. Waste heat from AC systems has a smaller effect ( 1°C) on the afternoon 2 m air temperature than the evening one (1.5 2.4°C) if AC systems work for 24 h and vent sensible waste heat into air. Influences of AC systems can only reach up to 400 m above the ground for the evening air temperature and humidity due to a shallower urban boundary layer than daytime. Spatially varying maps of AC working schedules and the ratio of sensible to latent waste heat release are critical for correctly simulating the cooling electric loads and capturing the thermal stratification of urban boundary layer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitts, D.R.
1980-09-30
A conceptual design study for district heating of a 30-home subdivision located near the southeast extremity of the city of Elko, Nevada is presented. While a specific residential community was used in the study, the overall approach and methodologies are believed to be generally applicable for a large number of communities where low temperature geothermal fluid is available. The proposed district heating system utilizes moderate temperature, clean domestic water and existing community culinary water supply lines. The culinary water supply is heated by a moderate temperature geothermal source using a single heat exchanger at entry to the subdivision. The heatedmore » culinary water is then pumped to the houses in the community where energy is extracted by means of a water supplied heat pump. The use of heat pumps at the individual houses allows economic heating to result from supply of relatively cool water to the community, and this precludes the necessity of supplying objectionably hot water for normal household consumption use. Each heat pump unit is isolated from the consumptive water flow such that contamination of the water supply is avoided. The community water delivery system is modified to allow recirculation within the community, and very little rework of existing water lines is required. The entire system coefficient of performance (COP) for a typical year of heating is 3.36, exclusive of well pumping energy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-09-01
Appendix A, Utility Plant Characteristics, contains information describing the characteristics of seven utility plants that were considered during the final site selection process. The plants are: Valley Electric Generating Plant, downtown Milwaukee; Manitowoc Electric Generating Plant, downtown Manitowoc; Blount Street Electric Generating Plant, downtown Madison; Pulliam Electric Generating Plant, downtown Green Bay; Edgewater Electric Generating Plant, downtown Sheboygan; Rock River Electric Generating Plant, near Janesville and Beloit; and Black Hawk Electric Generating Plant, downtown Beloit. Additional appendices are: Future Loads; hvac Inventory; Load Calculations; Factors to Induce Potential Users; Turbine Retrofit/Distribution System Data; and Detailed Economic Analysis Results/Data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dallmeyer, R.D.; Gee, D.G.; Beckholmen, M.
In central portions of the Scandinavian Caledonides, greenschist facies volcanosedimentary successions within the Koeli Nappe Complex have been thrust several hundred kilometers eastward onto the Baltoscandian platform. These were derived from eugeoclinal terranes situated outboard (west) of the Baltica continent during the early Paleozoic. The Koeli Nappe Complex is tectonically underlain by higher grade units within the Seve Nappe Complex. These are composed of amphibolite and granulite facies rocks and locally contain eclogites. The Seve Nappes tectonically separate Koeli units from structurally lower allochthons derived from more inboard environments along the Baltoscandian miogeocline. Previous mineral isotopic age-determinations from Seve andmore » Koeli units have been in the 430 to 390 Ma range and have been interpreted to presumably date cooling following Scandian (Middle Silurian to Early Devonian) metamorphism. However, incremental-release /sup 40/Ar//sup 39/Ar dates recorded by minerals within some of the Koeli and Seve Nappes exposed in Jaemtland, Sweden (Taennforsen and Are districts) provide evidence of earlier tectonothermal activity. Hornblendes from the Seve and Koeli Nappe Complexes display variably discordant age spectra as a result of low-temperature, experimental evolution of loosely bound extraneous argon components. However, in most analyses plateau ages of 510 to 475 Ma (Koeli) and 465 to 455 Ma (Seve) are defined. In contrast, muscovite and biotite from all tectonic units record Scandian cooling ages between 245 and 410 Ma. The older events recorded by hornblende within these Seve and Koeli units are evidence of early Caledonian tectonothermal activity and subsequent diachronous cooling during the Early-Middle Ordovician.« less
Origin and evolution of Gneiss-Charnockite rocks of Dharmapuri District, Tamil Nadu, India
NASA Technical Reports Server (NTRS)
Rao, D. Rameshwar; Narayana, B. L.
1988-01-01
A low- to high-grade transition area in Dharmapuri district was investigated petrologically and geochemically. The investigation confirmed the presence of a continuous section through a former lower crust, with felsic charnockites predominating the lower part and felsic gneisses the upper part. The structure of original gneisses is preserved in charnockites and the latter show petrographic evidence for prograde metamorphism. The prograde metamorphism is of isochemical nature as revealed by the similarity of compositions of tonalitic gneisses and tonalitic charnockites. However, the depletion of LIL elements particularly Rb, caused variation in K/Rb ratios from low values (345) in the gneisses in upper part to higher values (1775) in the charnockites in the lower crust. This variation in K/Rb ratio in a north to south traverse is related to the progressive break-down of hydrous minerals under decreasing H2O and increasing CO2 fluid conditions. Metasomatism and partial melting has also taken place to a limited extent along shear planes and weak zones. During cooling the H2O circulation affected substantial auto-regression in the transition zone resulting in the formation of second generation biotite.
IDEA Clean Energy Application Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, Robert P.
The DOE Clean Energy Application Centers were launched with a goal of focusing on important aspects of our nation’s energy supply including Efficiency, Reliability and Resiliency. Clean Energy solutions based on Combined Heat & Power (CHP), District Energy and Waste Heat Recovery are at the core of ensuring a reliable and efficient energy infrastructure for campuses, communities, and industry and public enterprises across the country. IDEA members which include colleges and universities, hospitals, airports, downtown utilities as well as manufacturers, suppliers and service providers have long-standing expertise in the planning, design, construction and operations of Clean Energy systems. They representmore » an established base of successful projects and systems at scale and serve important and critical energy loads. They also offer experience, lessons learned and best practices which are of immense value to the sustained growth of the Clean Energy sector. IDEA has been able to leverage the funds from the project award to raise the visibility, improve the understanding and increase deployment CHP, District Energy and Waste Heat Recovery solutions across the regions of our nation, in collaboration with the regional CEAC’s. On August 30, 2012, President Obama signed an Executive Order to accelerate investments in industrial energy efficiency (EE), including CHP and set a national goal of 40 GW of new CHP installation over the next decade IDEA is pleased to have been able to support this Executive Order in a variety of ways including raising awareness of the goal through educational workshops and Conferences and recognizing the installation of large scale CHP and district energy systems. A supporting key area of collaboration has involved IDEA providing technical assistance on District Energy/CHP project screenings and feasibility to the CEAC’s for multi building, multi-use projects. The award was instrumental in the development of a first-order screening/feasibility tool for these types of community energy projects. The Excel based tool incorporates hourly climate based building loads data to arrive at the composite energy demand for the district and compares the Net Present Value (NPV) of the costs of CHP/DE alternatives. This tool has been used to provide assistance to several projects in the Northeast, Mid-Atlantic, Intermountain and Pacific Regions. The tool was disseminated to the CEACs and supplemented by a Training Webinar and a How to Guide IDEA produced a US Community Energy Development Guide to support mayors, planners, community leaders, real estate developers and economic development officials who are interested in planning more sustainable urban energy infrastructure, creating community energy master plans and implementing CHP/ District Energy systems in cities, communities and towns. IDEA has collected industry data and provided a comprehensive data set containing information on District Energy installations in the US. District energy systems are present in 49 states and theDistrict of Columbia. Of the 597 systems 55% were DE alone while the remainder was some combination of CHP, district heating, and district cooling. District energy systems that do not currently involve electric generation are strong near-term candidates for the adoption of CHP due to the magnitude of their aggregated thermal load. This data has helped inform specific and targeted initiatives including technical assistance provided by the CEAC’s for EPA’s Boiler MACT Compliance by large District Heating System boilers. These outcomes have been greatly enabled by the close coordination and collaboration with DOE CEAC leadership and with the eight regional US DOE Clean Energy Application Centers and the award’s incremental funding has allowed IDEA to leverage our resources to be an effective champion for Clean Energy.« less
NASA Astrophysics Data System (ADS)
Kotková, Jana; Kullerud, Kåre; Šrein, Vladimír; Drábek, Milan; Škoda, Radek
2018-04-01
The Kongsberg silver district has been investigated by microscopy and electron microprobe analysis, focusing primarily on the Ag-Hg-Sb mineralization within the context of the updated mineral paragenesis. The earliest mineralization stage is represented by sulfides, including acanthite, and sulfosalts. Native silver formed initially through breakdown of early Ag-bearing phases and later through influx of additional Ag-bearing fluids and silver remobilization. The first two generations of native silver were separated in time by the formation of Ni-Co-Fe sulfarsenides and the monoarsenide niccolite along rims of silver crystals. The presence of As-free sulfosalts and the absence of di- and tri-arsenides suggest a lower arsenic/sulfur activity ratio for the Kongsberg deposits compared to other five-element deposits. Native silver shows binary Ag-Hg and Ag-Sb solid solutions, in contrast to the ternary Ag-Hg-Sb compositions typical for other deposits of similar type. Antimonial silver together with allargentum, dyscrasite, and pyrargyrite was documented exclusively from the northern area of the district. Elsewhere, the only Sb-bearing minerals are polybasite and tetrahedrite/freibergite. Hg-rich silver (up to 21 wt% Hg) has been documented only in the central-western area. Myrmekite of freibergite and chalcopyrite reflects exsolution from an original Ag-poor tetrahedrite upon cooling, while myrmekite of pyrite and silver, forming through breakdown of low-temperature phases (argentopyrite or lenaite) upon heating, characterizes the Kongsberg silver district. Based on the stabilities of minerals and mineral assemblages, the formation of the silver mineralization can be constrained to temperatures between 180 and 250 °C.
Intelligent Facades for High Performance Green Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dyson, Anna
Progress Towards Net-Zero and Net-Positive-Energy Commercial Buildings and Urban Districts Through Intelligent Building Envelope Strategies Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, wemore » have undertaken a high-performance building integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring onsite solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets. With a team that spans multiple stakeholders across disparate industries, from CPV to A&E partners that are responsible for the design and development of District and Regional Scale Urban Development, this project demonstrates that integrating utility-scale high efficiency CPV installations with urban and suburban environments is both viable and desirable within the marketplace. The historical schism between utility scale CPV and BIPV has been one of differing scale and cultures. There is no technical reason why utility-scale CPV cannot be located within urban embedded district scale sites of energy harvesting. New models for leasing large areas of district scale roofs and facades are emerging, such that the model for utility scale energy harvesting can be reconciled to commercial and public scale building sites and campuses. This consortium is designed to unite utility scale solar harvesting into building applications for smart grid development.« less
Placement and efficiency effects on radiative forcing of solar installations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burg, Brian R.; Ruch, Patrick; Paredes, Stephan
2015-09-28
The promise for harnessing solar energy being hampered by cost, triggered efforts to reduce them. As a consequence low-efficiency, low-cost photovoltaics (PV) panels prevail. Conversely, in the traditional energy sector efficiency is extremely important due to the direct costs associated to fuels. This also affects solar energy due to the radiative forcing caused by the dark solar panels. In this paper we extend the concept of energy payback time by including the effect of albedo change, which gives a better assessment of the system sustainability. We present an analysis on the short and medium term climate forcing effects of differentmore » solar collectors in Riyadh, Saudi Arabia and demonstrate that efficiency is important to reduce the collector area and cost. This also influences the embodied energy and the global warming potential. We show that a placement of a high concentration photovoltaic thermal solar power station outside of the city using a district cooling system has a double beneficial effect since it improves the solar conversion efficiency and reduces the energy demand for cooling in the city. We also explain the mechanisms of the current economic development of solar technologies and anticipate changes.« less
Greenbuilt Retrofit Test House Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sparn, B.; Hudon, K.; Earle, L.
2014-06-01
The Greenbuilt house is a 1980's era house in the Sacramento area that was a prominent part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration Program. The house underwent an extensive remodel, aimed at improving overall energy efficiency with a goal of reducing the home's energy use by 50%. NREL researchers performed a number of tests on the major systems touched by the retrofit to ensure they were working as planned. Additionally, SMUD rented the house from Greenbuilt Construction for a year to allow NREL to perform a number of tests on the cooling system and the watermore » heating system. The goal of the space conditioning tests was to find the best ways to cut cooling loads and shift the summer peak. The water heating system, comprised of an add-on heat pump water heater and an integrated collector-storage solar water heater, was operated with a number of different draw profiles to see how varying hot water draw volume and schedule affected the performance of the system as a whole. All the experiments were performed with the house empty, with a simulated occupancy schedule running in the house to mimic the load imposed by real occupants.« less
NASA Astrophysics Data System (ADS)
Patterson, Jeffrey E.
The emplacement mechanisms and cooling characteristics of pegmatites are not well understood, yet little work has been done on this subject. Historically, it is the pegmatite mineralogy and zonation that has been the focus of attention because of fascination with giant sized crystals, diversity of mineralization, and abundance of minerals containing important strategic elements, (Li, Be, Ta, Nb, and others). In this thesis the subject of the emplacement mechanisms is a synergistic approach from geophysical and engineering viewpoints, using the principals of fracture mechanics to determine the properties related to emplacement. From this, the cooling characteristics are considered to explain the zonation of a pegmatite based upon the temperature of crystallization of each mineral. This provides a model to image the position of each mineral according to the temperature profiles over time. Finally, the mineral growth characteristics are considered in light of the boundary conditions placed upon them by the cooling period. To test these hypothetical conditions in the real world, the Stewart Lithia Pegmatite, Pala, California, has been evaluated both physically and geochemically. The structure of the pegmatite was examined along strike and along dip, as exposed in underground workings. The analyses of these data show that there are 5 discreet divisions along strike. The analyses of the geochemical data for precisely located tourmalines shows that these divisions are composed of approximately 10 discreet pulses, with the economically important "Chimney Division" containing all 10. The importance of this work is that it demonstrates the following. A complex pegmatite is more likely to consist of multiple pulses of different melt composition than a single pulse with un-explainable mineralogy and zonation; Giant crystals are more likely due to rapid polymerization of a few mineral species where the cooling rate and crystallization rate are nearly equal; The range of mineral sizes to eleven orders of magnitude is due to the minimal rate of cooling, with the smallest crystals nucleating and not growing because there is no thermal differential driving force; and gem crystals generally only occur in fluid filled miarolitic cavities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-01-31
This volume begins with an Introduction summarizing the history, methodology and scope of the study, the project team members and the private and public groups consulted in the course of the study. The Load and Service Area Assessment follows, including: a compilation and analysis of existing statistical thermal load data from census data, industrial directories, PSE and G records and other sources; an analysis of responses to a detailed, 4-page thermal load questionnaire; data on public buildings and fuel and energy use provided by the New Jersey Dept. of Energy; and results of other customer surveys conducted by PSE andmore » G. A discussion of institutional questions follows. The general topic of rates is then discussed, including a draft hypothetical Tariff for Thermal Services. Financial considerations are discussed including a report identifying alternative ownership/financing options for district heating systems and the tax implications of these options. Four of these options were then selected by PSE and G and a financial (cash-flow) analysis done (by the PSE and G System Planning Dept.) in comparison with a conventional heating alternative. Year-by-year cost of heat ($/10/sup 6/ Btu) was calculated and tabulated, and the various options compared.« less
Concept of turbines for ultrasupercritical, supercritical, and subcritical steam conditions
NASA Astrophysics Data System (ADS)
Mikhailov, V. E.; Khomenok, L. A.; Pichugin, I. I.; Kovalev, I. A.; Bozhko, V. V.; Vladimirskii, O. A.; Zaitsev, I. V.; Kachuriner, Yu. Ya.; Nosovitskii, I. A.; Orlik, V. G.
2017-11-01
The article describes the design features of condensing turbines for ultrasupercritical initial steam conditions (USSC) and large-capacity cogeneration turbines for super- and subcritical steam conditions having increased steam extractions for district heating purposes. For improving the efficiency and reliability indicators of USSC turbines, it is proposed to use forced cooling of the head high-temperature thermally stressed parts of the high- and intermediate-pressure rotors, reaction-type blades of the high-pressure cylinder (HPC) and at least the first stages of the intermediate-pressure cylinder (IPC), the double-wall HPC casing with narrow flanges of its horizontal joints, a rigid HPC rotor, an extended system of regenerative steam extractions without using extractions from the HPC flow path, and the low-pressure cylinder's inner casing moving in accordance with the IPC thermal expansions. For cogeneration turbines, it is proposed to shift the upper district heating extraction (or its significant part) to the feedwater pump turbine, which will make it possible to improve the turbine plant efficiency and arrange both district heating extractions in the IPC. In addition, in the case of using a disengaging coupling or precision conical bolts in the coupling, this solution will make it possible to disconnect the LPC in shifting the turbine to operate in the cogeneration mode. The article points out the need to intensify turbine development efforts with the use of modern methods for improving their efficiency and reliability involving, in particular, the use of relatively short 3D blades, last stages fitted with longer rotor blades, evaporation techniques for removing moisture in the last-stage diaphragm, and LPC rotor blades with radial grooves on their leading edges.
Legionella pollution in cooling tower water of air-conditioning systems in Shanghai, China.
Lin, H; Xu, B; Chen, Y; Wang, W
2009-02-01
To determine Legionella pollution prevalence, describe the amount of Legionellae with respect to temperature in Shanghai cooling tower water (CTWs) in various types of public sites. Six urban districts were selected as the study fields, adopting multiple-phase sampling methods. Routine culture was used to identify Legionellae. Of the samples, 58.9% (189/321) were observed to be positive, 19.9% were isolated over 100 CFU ml(-1). Legionella pneumophila serogroup 1 was the most frequently isolated species (155/189, 82.0%), followed by Leg. micdadei that was at the second place (44/189, 23.3%). The mean CFU ml(-1) of Legionellae in CTWs reached its peak from July to September. Over all 15.4% of the samples exceeding 100 CFU ml(-1) were observed in a hospital setting. The prevalence of Legionella pollution in CTWs, especially in CTWs of subway stations and hospitals, is worrying, and the positive rate and CFU ml(-1) of Legionellae in CTWs have a close relationship with air temperature. The study demonstrates pollution prevalence rates in different types of sites and various seasons, and provides a proportion of different serogroups of Legionellae. It illuminates an urgent need for dealing with the potential risk of legionellosis in Shanghai, through improved control and prevention strategies.
Analysis of Low-Temperature Utilization of Geothermal Resources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Brian
Full realization of the potential of what might be considered “low-grade” geothermal resources will require that we examine many more uses for the heat than traditional electricity generation. To demonstrate that geothermal energy truly has the potential to be a national energy source we will be designing, assessing, and evaluating innovative uses for geothermal-produced water such as hybrid biomass-geothermal cogeneration of electricity and district heating and efficiency improvements to the use of cellulosic biomass in addition to utilization of geothermal in district heating for community redevelopment projects. The objectives of this project were: 1) to perform a techno-economic analysis ofmore » the integration and utilization potential of low-temperature geothermal sources. Innovative uses of low-enthalpy geothermal water were designed and examined for their ability to offset fossil fuels and decrease CO2 emissions. 2) To perform process optimizations and economic analyses of processes that can utilize low-temperature geothermal fluids. These processes included electricity generation using biomass and district heating systems. 3) To scale up and generalize the results of three case study locations to develop a regionalized model of the utilization of low-temperature geothermal resources. A national-level, GIS-based, low-temperature geothermal resource supply model was developed and used to develop a series of national supply curves. We performed an in-depth analysis of the low-temperature geothermal resources that dominate the eastern half of the United States. The final products of this study include 17 publications, an updated version of the cost estimation software GEOPHIRES, and direct-use supply curves for low-temperature utilization of geothermal resources. The supply curves for direct use geothermal include utilization from known hydrothermal, undiscovered hydrothermal, and near-hydrothermal EGS resources and presented these results at the Stanford Geothermal Workshop. We also have incorporated our wellbore model into TOUGH2-EGS and began coding TOUGH2-EGS with the wellbore model into GEOPHIRES as a reservoir thermal drawdown option. Additionally, case studies for the WVU and Cornell campuses were performed to assess the potential for district heating and cooling at these two eastern U.S. sites.« less
Fukushima Daiichi Nuclear Accident; based on the Final Report of Atomic Energy Society of Japan
NASA Astrophysics Data System (ADS)
Sekimura, Naoto
2014-09-01
The Atomic Energy Society of Japan (AESJ) published the Final Report of the AESJ Investigation Committee on Fukushima Daiichi NPS Accident in March 2014. The AESJ is responsible to identify the underlying root causes of the accident through technical surveys and analyses, and to offer solutions for nuclear safety. At the Fukushima Daiichi, Units 1 to 3, which were under operation, were automatically shut down at 14:46 on March 11, 2011 by the Tohoku District-off the Pacific Ocean Earthquake. About 50 minutes later, the tsunami flooded and destroyed the emergency diesel generators, the seawater cooling pumps, the electric wiring system and the DC power for Units 1, 2 and 4, resulting in loss of all power except for an air-cooled emergency diesel generator at Unit 6. Unit 3 lost all AC power, and later lost DC before dawn of March 13. Cooling the reactors and monitoring the results were heavily dependent on electricity for high-pressure water injection, depressurizing the reactor, low pressure water injection, and following continuous cooling. In Unit 3, for example, recent re-evaluation in August 2014 by TEPCO shows that no cooling water was injected into the reactor core region after 8 PM on March 12, leading to the fuel melting from 5:30 AM on March 13. Even though seawater was injected from fire engines afterwards, the rupture of pressure vessel was caused and the majority of melted fuel dropped into the containment vessel of Unit 3. The estimation of amount of radioactive materials such as Xe-133, I-131, Cs-137 and Cs-134, emitted to the environment from Units 1 to 3 is discussed in the presentation. Direct causes of the accident identified in the AESJ Report were, 1) inadequate tsunami measures, 2) inadequate severe accident management measures and 3) inadequate emergency response, post-accident management/mitigation, and recovery measures. These were caused by the following underlying factors, i.e., a) lack of awareness on the roles and responsibilities by experts, b) shortfalls in establishing safety measures and fostering safety awareness by utilities, c) lack of safety awareness by the regulatory body, d) inadequacies in attitude of learning from efforts and collaborations in the international community, and e) shortage of qualified personnel to ensure safety and inadequacies in organization and management framework.
NASA Astrophysics Data System (ADS)
Eldursi, Khalifa; Branquet, Yannick; Guillou-Frottier, Laurent; Martelet, Guillaume; Calcagno, Philippe
2018-04-01
The Tighza (or Jebel Aouam) district is one of the most important polymetallic districts in Morocco. It belongs to the Variscan Belt of Central Meseta, and includes W-Au, Pb-Zn-Ag, and Sb-Ba mineralization types that are spatially related to late-Carboniferous granitic stocks. One of the proposed hypotheses suggests that these granitic stocks are connected to a large intrusive body lying beneath them and that W-Au mineralization is directly related to this magmatism during a 287-285 Ma time span. A more recent model argues for a disconnection between the older barren outcropping magmatic stocks and a younger hidden magmatic complex responsible for the W-Au mineralization. Independently of the magmatic scenario, the W-Au mineralization is consensually recognized as of intrusion-related gold deposit (IRGD) type, W-rich. In addition to discrepancies between magmatic sceneries, the IRGD model does not account for published older age corresponding to a high-temperature hydrothermal event at ca. 291 Ma. Our study is based on gravity data inversion and hydro-thermal modeling, and aims to test this model of IRGD and its related magmatic geometries, with respect to subsurface geometries, favorable physical conditions for deposition and time record of hydrothermal processes. Combined inversion of geology and gravity data suggests that an intrusive body is rooted mainly at the Tighza fault in the north and that it spreads horizontally toward the south during a trans-tensional event (D2). Based on the numerical results, two types of mineralization can be distinguished: 1) the "Pre-Main" type appears during the emplacement of the magmatic body, and 2) the "Main" type appears during magma crystallization and the cooling phase. The time-lag between the two mineralization types depends on the cooling rate of magma. Although our numerical model of thermally-driven fluid flow around the Tighza pluton is simplified, as it does not take into account the chemical and deformation contributions, it provides evidence for abandoning the time-lag as an argument for invalidating the existence of a genetic link between older mineralizations and/or hydrothermal events spatially related to younger parent plutons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-06-01
This environmental impact assessment addresses the design, construction, and operation of an electric generating plant (3 to 4 MWe) and research station (Hawaii Geothermal Research Station (HGRS)) in the Puna district on the Island of Hawaii. The facility will include control and support buildings, parking lots, cooling towers, settling and seepage ponds, the generating plant, and a visitors center. Research activities at the facility will evaluate the ability of a successfully flow-tested well (42-day flow test) to provide steam for power generation over an extended period of time (two years). In future expansion, research activities may include direct heat applicationsmore » such as aquaculture and the effects of geothermal fluids on various plant components and specially designed equipment on test modules. 54 refs., 7 figs., 22 tabs.« less
Analysis and assessment of STES technologies
NASA Astrophysics Data System (ADS)
Brown, D. R.; Blahnik, D. E.; Huber, H. D.
1982-12-01
Technical and economic assessments completed in FY 1982 in support of the Seasonal Thermal Energy Storage (STES) segment of the Underground Energy Storage Program included: (1) a detailed economic investigation of the cost of heat storage in aquifers, (2) documentation for AQUASTOR, a computer model for analyzing aquifer thermal energy storage (ATES) coupled with district heating or cooling, and (3) a technical and economic evaluation of several ice storage concepts. This paper summarizes the research efforts and main results of each of these three activities. In addition, a detailed economic investigation of the cost of chill storage in aquifers is currently in progress. The work parallels that done for ATES heat storage with technical and economic assumptions being varied in a parametric analysis of the cost of ATES delivered chill. The computer model AQUASTOR is the principal analytical tool being employed.
Seasonal thermal energy storage
NASA Astrophysics Data System (ADS)
Minor, J. E.
1980-03-01
The Seasonal Thermal Energy Storage (STES) Program demonstrates the economic storage and retrieval of thermal energy on a seasonal basis, using heat or cold available from waste or other sources during a surplus period to reduce peak period demand, reduce electric utilities peaking problems, and contribute to the establishment of favorable economics for district heating and cooling systems for commercialization of the technology. The STES Program utilizes ground water systems (aquifers) for thermal energy storage. The STES Program is divided into an Aquifer Thermal Energy Storage (ATES) Demonstration Task for demonstrating the commercialization potential of aquifer thermal energy storage technology using an integrated system approach to multiple demonstration projects and a parallel Technical Support Task designed to provide support to the overall STES Program, and to reduce technological and institutional barriers to the development of energy storage systems prior to significant investment in demonstration or commercial facilities.
Remotely sensed vegetation indices for seasonal crop yields predictions in the Czech Republic
NASA Astrophysics Data System (ADS)
Hlavinka, Petr; Semerádová, Daniela; Balek, Jan; Bohovic, Roman; Žalud, Zdeněk; Trnka, Miroslav
2015-04-01
Remotely sensed vegetation indices by satellites are valuable tool for vegetation conditions assessment also in the case of field crops. This study is based on the use of NDVI (Normalized Difference Vegetation Index) and EVI (Enhanced Vegetation Index) derived from MODIS (Moderate Resolution Imaging Spectroradiometer) aboard Terra satellite. Data available from the year 2000 were analyzed and tested for seasonal yields predictions within selected districts of the Czech Republic (Central Europe). Namely the yields of spring barley, winter wheat and oilseed winter rape during the period from 2000 to 2014 were assessed. Observed yields from 14 districts (NUTS 4) were collected and thus 210 seasons were included. Selected districts differ considerably in their soil fertility and terrain configuration and represent transect across various agroclimatic conditions (from warm and dry to relative cool and wet regions). Two approaches were tested: 1) using of composite remotely sensed data (available in 16 day time step) provided by the USGS (https://lpdaac.usgs.gov/); 2) using daily remotely sensed data in combination with originally developed smoothing method. The yields were successfully predicted based on established regression models (remotely sensed data used as independent parameter). Besides others the impact of severe drought episodes within vegetation were identified and yield reductions at district level predicted (even before harvest). As a result the periods with the best relationship between remotely sensed data and yields were identified. The impact of drought conditions as well as normal or above normal yields of field crops could be predicted by proposed method within study region up to 30 days prior to the harvest. It could be concluded that remotely sensed vegetation conditions assessment should be important part of early warning systems focused on drought. Such information should be widely available for various users (decision makers, farmers, etc.) in order to improve planning, business strategies but also to target the drought relief in case of major drought event. This study was funded by project "Building up a multidisciplinary scientific team focused on drought" No. CZ.1.07/2.3.00/20.0248, project supported by Czech National Agency of Agricultural Research No. QJ1310123 "Crop modelling as a tool for increasing the production potential and food security of the Czech Republic under Climate Change".
Reuse of heat energy in wastewater: implementation examples in Japan.
Funamizu, N; Iida, M; Sakakura, Y; Takakuwa, T
2001-01-01
Sewage and treated water can be a heat source in urban area due to large heat capacity, thus recovery and reuse of its energy is one of the most desirable plans for the sewerage system. In this paper, characteristics of heat energy in wastewater, reuse plans, and some experiences in Japan are presented. Full-scale reuse projects for heating and cooling in the Tokyo Metropolitan Districts and project for melting snow in Sapporo City are discussed. The key factors found in experience of Tokyo were setting the heat pumps near the demand points and the technical developments of equipment to prevent system from clogging, corrosion, and decrease in the heat transfer efficiency. It was also found through the project for melting snow in Sapporo that the key factor in public acceptance was the multi-purpose use of the sewerage system both for melting snow in winter and retaining rain water in summer.
Guidelines on Thermal Comfort of Air Conditioned Indoor Environment
NASA Astrophysics Data System (ADS)
Miura, Toyohiko
The thermal comfort of air conditioned indoor environment for workers depended, of course, on metabolic rate of work, race, sex, age, clothing, climate of the district and state of acclimatization. The attention of the author was directed to the seasonal variation and the sexual difference of comfortable temperature and a survey through a year was conducted on the thermal comfort, and health conditions of workers engaged in light work in a precision machine factory, in some office workers. Besides, a series of experiments were conducted for purpose of determinning the optimum temperature of cooling in summer time in relation to the outdoor temperature. It seemed that many of workers at present would prefer somewhat higher temperature than those before the World War II. Forty years ago the average homes and offices were not so well heated as today, and clothing worn on the average was considerably heavier.
Concentrated solar power in the built environment
NASA Astrophysics Data System (ADS)
Montenon, Alaric C.; Fylaktos, Nestor; Montagnino, Fabio; Paredes, Filippo; Papanicolas, Costas N.
2017-06-01
Solar concentration systems are usually deployed in large open spaces for electricity generation; they are rarely used to address the pressing energy needs of the built environment sector. Fresnel technology offers interesting and challenging CSP energy pathways suitable for the built environment, due to its relatively light weight (<30 kg.m-2) and low windage. The Cyprus Institute (CyI) and Consorzio ARCA are cooperating in such a research program; we report here the construction and integration of a 71kW Fresnel CSP system into the HVAC (Heating, Ventilation, and Air Conditioning) system of a recently constructed office & laboratory building, the Novel Technologies Laboratory (NTL). The multi-generative system will support cooling, heating and hot water production feeding the system of the NTL building, as a demonstration project, part of the STS-MED program (Small Scale Thermal Solar District Units for Mediterranean Communities) financed by the European Commission under the European Neighbourhood and Partnership Instrument (ENPI), CBCMED program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hicks, R.J.; Stewart, D.L.
1988-03-01
The primary objective of this study was to evaluate the potential environmental effects (both adverse and beneficials) of aquifer thermal energy storage (ATES) technology pertaining to microbial communities indigenous to subsurface environments (i.e., aquifers) and the propagation, movement, and potential release of pathogenic microorganisms (specifically, Legionella) within ATES systems. Seasonal storage of thermal energy in aquifers shows great promise to reduce peak demand; reduce electric utility load problems; contribute to establishing favorable economics for district heating and cooling systems; and reduce pollution from extraction, refining, and combustion of fossil fuels. However, concerns that the widespread implementation of this technology maymore » have adverse effects on biological systems indigeneous to aquifers, as well as help to propagate and release pathogenic organisms that enter thee environments need to be resolved. 101 refs., 2 tabs.« less
Rahalison, Lila; Rasolomaharo, Monique; Ratsitorahina, Maherisoa; Mahafaly, Mahafaly; Razafimahefa, Maminirana; Duplantier, Jean-Marc; Ratsifasoamanana, Lala; Chanteau, Suzanne
2002-01-01
From 1995 to 1998, outbreaks of bubonic plague occurred annually in the coastal city of Mahajanga, Madagascar. A total of 1,702 clinically suspected cases of bubonic plague were reported, including 515 laboratory confirmed by Yersinia pestis isolation (297), enzyme-linked immunosorbent assay, or both. Incidence was higher in males and young persons. Most buboes were inguinal, but children had a higher frequency of cervical or axillary buboes. Among laboratory-confirmed hospitalized patients, the case-fatality rate was 7.9%, although all Y. pestis isolates were sensitive to streptomycin, the recommended antibiotic. In this tropical city, plague outbreaks occur during the dry and cool season. Most cases are concentrated in the same crowded and insanitary districts, a result of close contact among humans, rats, and shrews. Plague remains an important public health problem in Madagascar, and the potential is substantial for spread to other coastal cities and abroad. PMID:11927030
Design and Implementation of Geothermal Energy Systems at West Chester University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, James
West Chester University has launched a comprehensive transformation of its campus heating and cooling systems from traditional fossil fuels to geothermal. This change will significantly decrease the institution's carbon footprint and serve as a national model for green campus efforts. The institution has designed a phased series of projects to build a district geo-exchange system with shared well fields, central pumping station and distribution piping to provide the geo-exchange water to campus buildings as their internal building HVAC systems are changed to be able to use the geo-exchange water. This project addresses the US Department of Energy Office of Energymore » Efficiency and Renewable Energy (EERE) goal to invest in clean energy technologies that strengthen the economy, protect the environment, and reduce dependence on foreign oil. In addition, this project advances EERE's efforts to establish geothermal energy as an economically competitive contributor to the US energy supply.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pind, C.
The SECURE heating reactor was designed by ASEA-ATOM as a realistic alternative for district heating in urban areas and for supplying heat to process industries. SECURE has unique safety characteristics, that are based on fundamental laws of physics. The safety does not depend on active components or operator intervention for shutdown and cooling of the reactor. The inherent safety characteristics of the plant cannot be affected by operator errors. Due to its very low environment impact, it can be sited close to heat consumers. The SECURE heating reactor has been shown to be competitive in comparison with other alternatives formore » heating Helsinki and Seoul. The SECURE heating reactor forms a basis for the power-producing SECURE-P reactor known as PIUS (Process Inherent Ultimate Safety), which is based on the same inherent safety principles. The thermohydraulic function and transient response have been demonstrated in a large electrically heated loop at the ASEA-ATOM laboratories.« less
NASA Astrophysics Data System (ADS)
Konovšek, Damjan; Fužir, Miran; Slatinek, Matic; Šepul, Tanja; Plesnik, Kristijan; Lečnik, Samo
2017-07-01
In a consortium with SIJ (Slovenian Steel Group), Metal Ravne, the local community of Ravne na Koro\\vskem and the public research Institut Jožef Stefan, with its registered office in Slovenia, Petrol Energetika, d.o.o. set up a technical and technological platform of an innovative energy case for a transition of steel industry into circular economy with a complete energy solution called »Utilization of Waste Heat from Metallurgical Processes for District Heating of Ravne na Koro\\vskem. This is the first such project designed for a useful utilization of waste heat in steel industry which uses modern technology and innovative system solutions for an integration of a smart, efficient and sustainable heating and cooling system and which shows a growth potential. This will allow the industry and cities to make energy savings, to improve the quality of air and to increase the benefits for the society we live in. On the basis of circular economy, we designed a target-oriented co-operation of economy, local community and public research institute to produce new business models where end consumers are put into the centre. This innovation opens the door for steel industry and local community to a joint aim that is a transition into efficient low-carbon energy systems which are based on involvement of natural local conditions, renewable energy sources, the use of waste heat and with respect for the principles of sustainable development.
Centennial and millennial-scale hydroclimate changes in northwestern Patagonia since 16,000 yr BP
NASA Astrophysics Data System (ADS)
Moreno, Patricio I.; Videla, Javiera
2016-10-01
We examine hydroclimate changes at centennial/millennial timescales since 16,000 yr BP in northwestern Patagonia based on the pollen and charcoal record from Lago El Salto, a small closed-basin lake located in the Chilean Lake District (41°38‧48.02″S, 73° 5‧48.42″W). We observe cold/wet conditions between 14,500-16,000 yr BP, followed by further cooling with increased precipitation until 13,000 yr BP, enhanced precipitation seasonality and/or variability between 11,600-13,000 yr BP, and an extended warm-and-dry interval between 7600 and 11,300 yr BP with peak paleofire activity. Colder-and-wetter than present conditions and muted paleofire activity prevail between 5300 and 7600 yr BP, followed by alternating cold/wet and centennial-scale warm/dry phases starting at 5300 yr BP with three conspicuous megadroughts since 2500 yr BP. The most recent megadrought occurred during the Medieval Climate Anomaly. We identify a cold reversal that spans the Antarctic Cold Reversal (ACR) and the Younger Dryas (YD) chrons with stronger-than-present westerly influence during the former and enhanced variability during the latter. These results extend the northern limit of strong cooling and increase in precipitation during the ACR and the southern limit of influence of strong hydrologic variations during the YD in terrestrial environments, suggesting an overlap in the spheres of influence of processes originating from southern and northern polar latitudes. An extended warm southern westerly wind (SWW)-minimum interval is evident between 7600 and 11,300 yr BP, followed by a rapid shift to cool-moist conditions between 5300 and 7600 yr BP brought by a mid-Holocene SWW maximum. Since then we observe centennial-scale hydroclimate variability, which has driven biodiversity and fire-regime shifts of evergreen temperate rainforests.
Key Assets for a Sustainable Low Carbon Energy Future
NASA Astrophysics Data System (ADS)
Carre, Frank
2011-10-01
Since the beginning of the 21st century, concerns of energy security and climate change gave rise to energy policies focused on energy conservation and diversified low-carbon energy sources. Provided lessons of Fukushima accident are evidently accounted for, nuclear energy will probably be confirmed in most of today's nuclear countries as a low carbon energy source needed to limit imports of oil and gas and to meet fast growing energy needs. Future challenges of nuclear energy are then in three directions: i) enhancing safety performance so as to preclude any long term impact of severe accident outside the site of the plant, even in case of hypothetical external events, ii) full use of Uranium and minimization long lived radioactive waste burden for sustainability, and iii) extension to non-electricity energy products for maximizing the share of low carbon energy source in transportation fuels, industrial process heat and district heating. Advanced LWRs (Gen-III) are today's best available technologies and can somewhat advance nuclear energy in these three directions. However, breakthroughs in sustainability call for fast neutron reactors and closed fuel cycles, and non-electric applications prompt a revival of interest in high temperature reactors for exceeding cogeneration performances achievable with LWRs. Both types of Gen-IV nuclear systems by nature call for technology breakthroughs to surpass LWRs capabilities. Current resumption in France of research on sodium cooled fast neutron reactors (SFRs) definitely aims at significant progress in safety and economic competitiveness compared to earlier reactors of this type in order to progress towards a new generation of commercially viable sodium cooled fast reactor. Along with advancing a new generation of sodium cooled fast reactor, research and development on alternative fast reactor types such as gas or lead-alloy cooled systems (GFR & LFR) is strategic to overcome technical difficulties and/or political opposition specific to sodium. In conclusion, research and technology breakthroughs in nuclear power are needed for shaping a sustainable low carbon future. International cooperation is key for sharing costs of research and development of the required novel technologies and cost of first experimental reactors needed to demonstrate enabling technologies. At the same time technology breakthroughs are developed, pre-normative research is required to support codification work and harmonized regulations that will ultimately apply to safety and security features of resulting innovative reactor types and fuel cycles.
El Salvador, Chile porphyry copper deposit revisited: Geologic and geochronologic framework
Cornejo, P.; Tosdal, R.M.; Mpodozis, C.; Tomlinson, A.J.; Rivera, O.; Fanning, C.M.
1997-01-01
The Eocene (42 to 41 Ma) El Salvador porphyry copper deposit in the Indio Muerto district, northern Chile (26?? 15??? S Lat.), formerly thought to have formed at the culmination of a 9-m.y. period of episodic magmatism, is shown by new mapping, U-Pb and K-Ar geochronology, and petrologic data to have formed during the younger of two distinct but superposed magmatic events - a Paleocene (???63 to 58 Ma) and an Eocene (44 to 41 Ma) event. In the district, high-K Paleocene volcano-plutonic activity was characterized by a variety of eruptive styles and magmatic compositions, including a collapse caldera associated with explosive rhyolitic magmatism (El Salvador trap-door caldera), a post-collapse rhyolite dome field (Cerro Indio Muerto), and andesitic-trachyandesitic stratovolcanos (Kilo??metro Catorce-Los Amarillos sequence). Precaldera basement faults were reactivated during Paleocene volcanism as part of the collapse margin of the caldera. Beneath Cerro Indio Muerto, where the porphyry Cu deposit subsequently formed, the intersection of two major basement faults and the NNE-striking rotational axis of tilted ignimbrites of the Paleocene El Salvador caldera localized emplacement of post-collapse rhyolite domes and peripheral dikes and sills. Subsequent Eocene rhyolitic and granodioritic-dacitic porphyries intruded ???14 m.y. after cessation of Paleocene magmatism along the same NNE-striking structural belt through Cerro Indio Muerto as did the post-collapse Paleocene rhyolite domes. Eocene plutonism over a 3-m.y. period was contemporaneous with NW-SE-directed shortening associated with regional sinistral transpression along the Sierra Castillo fault, lying ???10 km to the east. Older Eocene rhyolitic porphyries in the Indio Muerto district were emplaced between 44 and 43 Ma, and have a small uneconomic Cu center associated with a porphyry at Old Camp. The oldest granodioritic-dacitic porphyries also were emplaced at ???44 to 43 Ma, but their petrogenetic relation to the rhyolitic porphyries and younger granodioritic-dacitic porphyries in the district is unclear. The main porphyry Cu-Mo-related granodioritic-dacitic stocks in Quebrada Turquesa on Cerro Indio Muerto intruded, cooled, and were mineralized within ???1 m.y. between 42 and 41 Ma. Volumetrically minor late- to post-mineral porphyries are slightly more mafic than earlier granodioritic-dacitic porphyries, a compositional trend possibly repeated on several scales and more than once over the 3-million-year Eocene magmatic history of the Indio Muerto district. This compositional trend requires either addition of basaltic material into an open-system silicic magma chamber or tapping of progressively deeper levels of a vertically zoned magma chamber. Eocene porphyry magmas were more hydrous and their residual source mineralogy richer in garnet than the relatively anhydrous Paleocene rocks, whose source was rich in pyroxene. The presence of inherited zircons in Paleocene and Eocene rocks requires interaction with crustal rocks of Paleozoic and/ or Proterozoic age. Paleocene and Eocene igneous rocks in the Indio Muerto district were emplaced during distinct magmatic-tectonic events that are unrelated, although spatially associated. The district-scale Paleocene and Eocene eruptive styles and geochemical and mineralogic characteristics mimic characteristics of similar-aged igneous rocks throughout northern Chile (20??30??? S Lat. to 27?? S Lat.), attesting to the regional nature of the Paleocene and Eocene events. Porphyry Cu mineralization in the district furthermore is associated not only with an Eocene granodioritic-dacitic (42 to 41 Ma) complex, but also with one of an older Eocene (44 to 43 Ma) rhyolitic porphyry, implying that a long period of precursor magmatism is not required for generation of the El Salvador porphyry Cu-Mo deposit. Rather, the episodic magmatism preceding porphyry Cu mineralization reflects repeated structural localization through time of superimposed h
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shonder, J.A.
Geothermal heat pumps (GHPs) have been shown to have a number of benefits over other technologies used to heat and cool buildings and provide hot water, combining high levels of occupant comfort with low operating and maintenance costs. Public facilities represent an increasingly important market for GHPs, and schools are a particularly good application, given the large land area that normally surrounds them. Nevertheless, some barriers remain to the increased use of GHPs in institutional and commercial applications. First, because GHPs are perceived as having higher installation costs than other space conditioning technologies, they are sometimes not considered as anmore » option in feasibility studies. When they are considered, it can be difficult to compile the information required to compare them with other technologies. For example, a life cycle cost analysis requires estimates of installation costs and annually recurring energy and maintenance costs. But most cost estimators are unfamiliar with GHP technology, and no published GHP construction cost estimating guide is available. For this reason, estimates of installed costs tend to be very conservative, furthering the perception that GHPs are more costly than other technologies. Because GHP systems are not widely represented in the various softwares used by engineers to predict building energy use, it is also difficult to estimate the annual energy use of a building having GHP systems. Very little published data is available on expected maintenance costs either. Because of this lack of information, developing an accurate estimate of the life cycle cost of a GHP system requires experience and expertise that are not available in all institutions or in all areas of the country. In 1998, Oak Ridge National Laboratory (ORNL) entered into an agreement with the Lincoln, Nebraska, Public School District and Lincoln Electric Service, the local electric utility in the Lincoln area, to study four new, identical elementary schools built in the district that are served by GHPs. ORNL was provided with complete as-built construction plans for the schools and associated equipment, access to original design calculations and cost estimates, extensive equipment operating data [both from the buildings' energy management systems (EMSs) and from utility meters], and access to the school district's complete maintenance record database, not only for the four GHP schools, but for the other schools in the district using conventional space conditioning equipment. Using this information, we were able to reproduce the process used by the Lincoln school district and the consulting engineering firm to select GHPs over other options to provide space conditioning for the four schools. The objective was to determine whether this decision was the correct one, or whether some other technology would have been more cost-effective. An additional objective was to identify all of the factors that make it difficult for building owners and their engineers to consider GHPs in their projects so that ongoing programs can remove these impediments over time.« less
NASA Astrophysics Data System (ADS)
Manzella, A.
2015-08-01
Geothermal technologies use renewable energy resources to generate electricity and direct use of heat while producing very low levels of greenhouse-gas (GHG) emissions. Geothermal energy is stored in rocks and in fluids circulating in the underground. Electricity generation usually requires geothermal resources temperatures of over 100°C. For heating, geothermal resources spanning a wider range of temperatures can be used in applications such as space and district heating (and cooling, with proper technology), spa and swimming pool heating, greenhouse and soil heating, aquaculture pond heating, industrial process heating and snow melting. Geothermal technology, which has focused so far on extracting naturally heated steam or hot water from natural hydrothermal reservoirs, is developing to more advanced techniques to exploit the heat also where underground fluids are scarce and to use the Earth as a potential energy battery, by storing heat. The success of the research will enable energy recovery and utilization from a much larger fraction of the accessible thermal energy in the Earth's crust.
Design and Implementation of Geothermal Energy Systems at West Chester University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuprak, Greg
West Chester University has launched a comprehensive transformation of its campus heating and cooling systems from traditional fossil fuels (coal, oil and natural gas) to geothermal. This change will significantly decrease the institution’s carbon footprint and serve as a national model for green campus efforts. The institution has designed a phased series of projects to build a district geo-exchange system with shared well fields, central pumping station and distribution piping to provide the geo-exchange water to campus buildings as their internal building HVAC systems is changed to be able to use the geo-exchange water. This project addresses the US Departmentmore » of Energy Office of Energy Efficiency and Renewable Energy (EERE) goal to invest in clean energy technologies that strengthen the economy, protect the environment, and reduce dependence on foreign oil. In addition, this project advances EERE’s efforts to establish geothermal energy as an economically competitive contributor to the US energy supply.« less
Numerical Simulation of the Effects of Water Surface in Building Environment
NASA Astrophysics Data System (ADS)
Li, Guangyao; Pan, Yuqing; Yang, Li
2018-03-01
Water body could affect the thermal environment and airflow field in the building districts, because of its special thermal characteristics, evaporation and flat surface. The thermal influence of water body in Tongji University Jiading Campus front area was evaluated. First, a suitable evaporation model was selected and then was applied to calculate the boundary conditions of the water surface in the Fluent software. Next, the computational fluid dynamics (CFD) simulations were conducted on the models both with and without water, following the CFD practices guidelines. Finally, the outputs of the two simulations were compared with each other. Results showed that the effect of evaporative cooling from water surface strongly depends on the wind direction and temperature decrease was about 2∼5°C. The relative humidity within the enclosing area was affected by both the building arrangement and surrounding water. An increase of about 0.1∼0.2m/s of wind speed induced by the water evaporation was observed in the open space.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bloomquist, R.G.
District heating and cooling (DHC) can provide multiple opportunities to reduce air emissions associated with space conditioning and electricity generation, which contribute 30% to 50% of all such emissions. When DHC is combined with cogeneration (CHP), maximum reductions in sulfur oxides (SO{sub x}), nitrogen oxides (NO{sub x}), carbon dioxide (CO{sub 2}), particulates, and ozone-depleting chlorofluorocarbon (CFC) refrigerants can most effectively be achieved. Although significant improvements in air quality have been documented in Europe and Scandinavia due to DHC and CHP implementation, accurately predicting such improvements has been difficult. Without acceptable quantification methods, regulatory bodies are reluctant to grant air emissionsmore » credits, and local community leaders are unwilling to invest in DHC and CHP as preferred methods of providing energy or strategies for air quality improvement. The recent development and release of a number of computer models designed specifically to provide quantification of air emissions that can result from DHC and CHP implementation should help provide local, state, and national policymakers with information vital to increasing support and investment in DHC development.« less
ERIC Educational Resources Information Center
LiCalsi, Christina; Citkowicz, Martyna; Friedman, Lawrence B.; Brown, Megan
2015-01-01
The Massachusetts Office of District and School Turnaround (ODST) assists the Commissioner's Districts (the 10 largest districts in the state) and schools within those districts. The assistance focuses on turning around the lowest performing schools in the district while building district capacity to support improvement in other district schools.…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-16
... FXRS1265066CCP0] Huron Wetland Management District, Madison Wetland Management District, and Sand Lake Wetland... assessment (EA) involving Huron, Madison, and Sand Lake Wetland Management Districts (Districts). In this..., Madison Wetland Management District, Sand Lake Wetland Management District final CCP'' in the subject line...
Understanding School District Budgets: A Guide For Local Leaders
ERIC Educational Resources Information Center
Perry, Mary
2005-01-01
A school district budget is more than numbers. It is a record of a district?s past decisions and a spending plan for its future. It shows a district?s priorities whether they have been clearly articulated or simply occurred by default. And it is a communications document that can tell constituents a lot about the district?s priorities and goals. A…
Publications - SR 68 | Alaska Division of Geological & Geophysical Surveys
Mining District; Base Metals; Bethel Mining District; Bismuth; Black Mining District; Bluff (Place ; Livengood Mining District; Lode; Marshall Mining District; Massive Sulfide Deposit; Massive Sulfide Occurrence; Massive Sulfide Prospect; Massive Sulfides; McGrath Mining District; Melozitna Mining District
Lin, Shao; Kielb, Christine L; Reddy, Amanda L; Chapman, Bonnie R; Hwang, Syni-An
2012-03-01
Good school indoor air quality (IAQ) can affect the health and functioning of school occupants. Thus, it is important to assess the degree to which schools and districts employ strategies to ensure good IAQ management. We examined and compared the patterns of IAQ management strategies between public elementary schools and their school districts in New York State. District-level information obtained from surveys of district facilities managers in 326 districts was described and stratified by district size and socioeconomic status. School-level information obtained from surveys of head custodians in 770 elementary schools was then compared with the district-level information in 241 districts. About 47% of participating school districts reported having a district-wide IAQ program, with a large range in the prevalence of specific IAQ management strategies. Airing out newly painted areas was the most commonly reported (92%) and having a classroom animal policy was the least commonly reported (29%). Larger districts and districts with a district-wide IAQ program were more likely to report certain IAQ strategies than other districts. Elementary schools and their districts were most likely to report airing out newly painted areas (76%). The most common area of disagreement was construction after hours (50%). The top strategy not reported at either level was having an IAQ coordinator (53%). Many school districts lack key IAQ management strategies, and differences exist between district-level policy and school-level practice. Districts and schools should work together to formalize and expand existing IAQ policies and inform stakeholders about these strategies. © 2012, American School Health Association.
Healthy Schools Initiative: Implementation Study in Four San Mateo County School Districts
ERIC Educational Resources Information Center
Westrich, Lisa; Sanchez, Monika; Strobel, Karen; Duong, Nina
2012-01-01
The Sequoia Healthcare District (SHD), in collaboration with four local school districts--Belmont-Redwood Shores School District (BRSSD), Redwood City School District (RCSD), San Carlos School District (SCSD), and Sequoia Union High School District (SUHSD)--launched the Healthy Schools Initiative (HSI) in August 2010. This three-year initiative is…
King, Jonathan D; Teferi, Tesfaye; Cromwell, Elizabeth A; Zerihun, Mulat; Ngondi, Jeremiah M; Damte, Mesele; Ayalew, Frew; Tadesse, Zerihun; Gebre, Teshome; Mulualem, Ayelign; Karie, Alemu; Melak, Berhanu; Adugna, Mitku; Gessesse, Demelash; Worku, Abebe; Endashaw, Tekola; Admassu Ayele, Fisseha; Stoller, Nicole E; King, Mary Rose A; Mosher, Aryc W; Gebregzabher, Tesfaye; Haileysus, Geremew; Odermatt, Peter; Utzinger, Jürg; Emerson, Paul M
2014-03-01
To eliminate blinding trachoma, the World Health Organization emphasizes implementing the SAFE strategy, which includes annual mass drug administration (MDA) with azithromycin to the whole population of endemic districts. Prevalence surveys to assess impact at the district level are recommended after at least 3 years of intervention. The decision to stop MDA is based on a prevalence of trachomatous inflammation follicular (TF) among children aged 1-9 years below 5% at the sub-district level, as determined by an additional round of surveys limited within districts where TF prevalence is below 10%. We conducted impact surveys powered to estimate prevalence simultaneously at the sub-district and district in two zones of Amhara, Ethiopia to determine whether MDA could be stopped. Seventy-two separate population-based, sub-district surveys were conducted in 25 districts. In each survey all residents from 10 randomly selected clusters were screened for clinical signs of trachoma. Data were weighted according to selection probabilities and adjusted for correlation due to clustering. Overall, 89,735 residents were registered from 21,327 households of whom 72,452 people (80.7%) were examined. The prevalence of TF in children aged 1-9 years was below 5% in six sub-districts and two districts. Sub-district level prevalence of TF in children aged 1-9 years ranged from 0.9-76.9% and district-level from 0.9-67.0%. In only one district was the prevalence of trichiasis below 0.1%. The experience from these zones in Ethiopia demonstrates that impact assessments designed to give a prevalence estimate of TF at sub-district level are possible, although the scale of the work was challenging. Given the assessed district-level prevalence of TF, sub-district-level surveys would have been warranted in only five districts. Interpretation was not as simple as stopping MDA in sub-districts below 5% given programmatic challenges of exempting sub-districts from a highly regarded program and the proximity of hyper-endemic sub-districts.
Intra-Operational Area Coordination: The Zone EOC Concept
2015-09-01
Coastside County Water District, Granada Community Services District, Highlands Recreation District, Mid-peninsula Regional Open Space District...District, San Mateo County Resource Conservation District, and the unincorporated area communities of El Granada , Highlands-Bay Wood Park, Kings
NASA Astrophysics Data System (ADS)
Soltanzadeh, Iman; Bonnardot, Valérie; Sturman, Andrew; Quénol, Hervé; Zawar-Reza, Peyman
2017-08-01
Global warming has implications for thermal stress for grapevines during ripening, so that wine producers need to adapt their viticultural practices to ensure optimum physiological response to environmental conditions in order to maintain wine quality. The aim of this paper is to assess the ability of the Weather Research and Forecasting (WRF) model to accurately represent atmospheric processes at high resolution (500 m) during two events during the grapevine ripening period in the Stellenbosch Wine of Origin district of South Africa. Two case studies were selected to identify areas of potentially high daytime heat stress when grapevine photosynthesis and grape composition were expected to be affected. The results of high-resolution atmospheric model simulations were compared to observations obtained from an automatic weather station (AWS) network in the vineyard region. Statistical analysis was performed to assess the ability of the WRF model to reproduce spatial and temporal variations of meteorological parameters at 500-m resolution. The model represented the spatial and temporal variation of meteorological variables very well, with an average model air temperature bias of 0.1 °C, while that for relative humidity was -5.0 % and that for wind speed 0.6 m s-1. Variation in model performance varied between AWS and with time of day, as WRF was not always able to accurately represent effects of nocturnal cooling within the complex terrain. Variations in performance between the two case studies resulted from effects of atmospheric boundary layer processes in complex terrain under the influence of the different synoptic conditions prevailing during the two periods.
Case study of controlled recirculation at a Wyoming trona mine
Pritchard, C.; Scott, D.; Frey, G.
2015-01-01
Controlled recirculation has been used in the metal/nonmetal mining industry for energy savings when heating and cooling air, in undersea mining and for increasing airflow to mining areas. For safe and effective use of controlled district recirculation, adequate airflow to dilute contaminants must exist prior to implementation, ventilation circuit parameters must be accurately quantified, ventilation network modeling must be up to date, emergency planning scenarios must be performed and effective monitoring and control systems must be installed and used. Safety and health issues that must be considered and may be improved through the use of controlled district recirculation include blasting fumes, dust, diesel emissions, radon and contaminants from mine fires. Controlled recirculation methods are expected to become more widely used as mines reach greater working depths, requiring that these health and safety issues be well understood. The U.S. National Institute for Occupational Safety and Health (NIOSH) conducted two controlled recirculation tests over three days at a Wyoming trona mine, utilizing an inline booster fan to improve airflow to a remote and difficult-to-ventilate development section. Test results were used to determine the effect that recirculation had on air qualities and quantities measured in that section and in other adjacent areas. Pre-test conditions, including ventilation quantities and pressures, were modeled using VnetPC. During each test, ventilation quantities and pressures were measured, as well as levels of total dust. Sulfur hexafluoride (SF6) tracer gas was used to simulate a mine contaminant to monitor recirculation wave cycles. Results showed good correlation between the model results and measured values for airflows, pressure differentials, tracer gas arrival times, mine gasses and dust levels. PMID:26251567
Heywood, Peter; Harahap, Nida P
2009-01-01
Background During the Suharto era public funding of health in Indonesia was low and the health services were tightly controlled by the central government; district health staff had practically no discretion over expenditure. Following the downfall of President Suharto there was a radical political, administrative and fiscal decentralization with delivery of services becoming the responsibility of district governments. In addition, public funding for health services more than doubled between 2001 and 2006. It was widely expected that services would improve as district governments now had both more adequate funds and the responsibility for services. To date there has been little improvement in services. Understanding why services have not improved requires careful study of what is happening at the district level. Methods We collected information on public expenditure on health services for the fiscal year 2006 in 15 districts in Java, Indonesia from the district health offices and district hospitals. Data obtained in the districts were collected by three teams, one for each province. Information on district government revenues were obtained from district public expenditure databases maintained by the World Bank using data from the Ministry of Finance. Results The public expenditure information collected in 15 districts as part of this study indicates district governments are reliant on the central government for as much as 90% of their revenue; that approximately half public expenditure on health is at the district level; that at least 40% of district level public expenditure on health is for personnel, almost all of them permanent civil servants; and that districts may have discretion over less than one-third of district public expenditure on health; the extent of discretion over spending is much higher in district hospitals than in the district health office and health centers. There is considerable variation between districts. Conclusion In contrast to the promise of decentralization there has been little increase in the potential for discretion at the district level in managing public funds for health – this is likely to be an important reason for the lack of improvement in publicly funded health services. Key decisions about money are still made by the central government, and no one is held accountable for the performance of the sector – the district blames the center and the central ministries (and their ministers) are not accountable to district populations. PMID:19371410
Heywood, Peter; Harahap, Nida P
2009-04-16
During the Suharto era public funding of health in Indonesia was low and the health services were tightly controlled by the central government; district health staff had practically no discretion over expenditure. Following the downfall of President Suharto there was a radical political, administrative and fiscal decentralization with delivery of services becoming the responsibility of district governments. In addition, public funding for health services more than doubled between 2001 and 2006. It was widely expected that services would improve as district governments now had both more adequate funds and the responsibility for services. To date there has been little improvement in services. Understanding why services have not improved requires careful study of what is happening at the district level. We collected information on public expenditure on health services for the fiscal year 2006 in 15 districts in Java, Indonesia from the district health offices and district hospitals. Data obtained in the districts were collected by three teams, one for each province. Information on district government revenues were obtained from district public expenditure databases maintained by the World Bank using data from the Ministry of Finance. The public expenditure information collected in 15 districts as part of this study indicates district governments are reliant on the central government for as much as 90% of their revenue; that approximately half public expenditure on health is at the district level; that at least 40% of district level public expenditure on health is for personnel, almost all of them permanent civil servants; and that districts may have discretion over less than one-third of district public expenditure on health; the extent of discretion over spending is much higher in district hospitals than in the district health office and health centers. There is considerable variation between districts. In contrast to the promise of decentralization there has been little increase in the potential for discretion at the district level in managing public funds for health - this is likely to be an important reason for the lack of improvement in publicly funded health services. Key decisions about money are still made by the central government, and no one is held accountable for the performance of the sector - the district blames the center and the central ministries (and their ministers) are not accountable to district populations.
DOT National Transportation Integrated Search
1986-01-01
This report contains the initial Problem Identification for the Comprehensive Community-Based Traffic Safety Program (CCBP). Two DMV districts, District 2 and District 7, have been selected as the pilot areas for the CCBP, and because both districts ...
7 CFR 7.27 - Political activity.
Code of Federal Regulations, 2012 CFR
2012-01-01
... members of school boards, soil conservation district boards, weed control district boards, or of similar..., irrigation district boards, drainage district boards, weed control district boards, or for similar boards are...
7 CFR 7.27 - Political activity.
Code of Federal Regulations, 2011 CFR
2011-01-01
... members of school boards, soil conservation district boards, weed control district boards, or of similar..., irrigation district boards, drainage district boards, weed control district boards, or for similar boards are...
Suburban District Leaders' Perception of Their Practices
ERIC Educational Resources Information Center
Garcia France, Roxanne
2013-01-01
In the field of district leadership, most studies focus only on the context and conditions existing in large urban districts in need of reform. This study examined whether district leadership practices have applicability to district leaders working within the suburban context. In addition, it determined whether district conditions (i.e., district…
Chriqui, Jamie F; Eyler, Amy; Carnoske, Cheryl; Slater, Sandy
2013-01-01
To examine the influence of state laws and district policies on district-wide elementary school and middle school practices related to physical education (PE) time and the percentage of moderate-to-vigorous physical activity (MVPA) time during PE. Multivariate, cross-sectional analysis of state laws, district wellness and PE policies, and district PE practices for school year 2010-2011 controlling for district-level urbanicity, region, size, race/ethnicity of students, and socioeconomic status and clustered on state. One hundred ninety-five public school districts located in 42 states. District-level PE coordinators for the included districts who responded to an online survey. Minutes and days of PE per week and percent time spent in MVPA during PE time. District PE coordinators reported significantly less PE time than national standards-82.9 and 189.6 minutes at the elementary school and middle school levels, respectively. Physical education was provided an average of 2.5 and 3.7 days per week, respectively; and the percentage of MVPA time in PE was 64.4% and 65.7%, respectively. At the elementary school level, districts in either states with laws governing PE time or in a state and district with a law/policy reported significantly more days of PE (0.63 and 0.67 additional days, respectively), and districts in states with PE time laws reported 18 more minutes of PE per week. At the middle school level, state laws were associated with 0.73 more days of PE per week. Neither state laws nor district policies were positively associated with percent MVPA time in PE. State laws and district policies can influence district-level PE practices-particularly those governing the frequency and duration of PE-although opportunities exist to strengthen PE-related laws, policies, and practices.
Castor, S.B.; Boden, D.R.; Henry, C.D.; Cline, J.S.; Hofstra, A.H.; McIntosh, W.C.; Tosdal, R.M.; Wooden, J.P.
2003-01-01
The Tuscarora mining district contains the oldest and the only productive Eocene epithermal deposits in Nevada. The district is a particularly clear example of association of low-sulfidation deposits with igneous activity and structure, and it is unusual in that it consists of two adjoining but physically and chemically distinct types of low-sulfidation deposits. Moreover, Tuscarora deposits are of interest because they formed contemporaneously with nearby, giant Carlin-type gold deposits. The Tuscarora deposits formed within the 39.9 to 39.3 Ma Tuscarora volcanic field, along and just outside the southeastern margin of the caldera-like Mount Blitzen volcanic center. Both deposit types formed at 39.3 Ma, contemporaneous with the only major intrusive activity in the volcanic field. No deposits are known to have formed during any of the intense volcanic phases of the field. Intrusions were the apparent heat source, and structures related to the Mount Blitzen center were conduits for hydrothermal circulation. The ore-forming fluids interacted dominantly with Eocene igneous rocks. The two deposit types occur in a northern silver-rich zone that is characterized by relatively high Ag/Au ratios (110-150), narrow alteration zones, and quartz and carbonate veins developed mostly in intrusive dacite, and in a southern gold-rich zone that is typified by relatively low Ag/Au ratios (4-14), more widespread alteration, and quartz-fissure and stockwork veins commonly developed in tuffaceous sedimentary rocks. The deposit types have similar fluid inclusion and Pb and S isotope characteristics but different geochemical signatures. Quartz veins from both zones have similar thermal and paragenetic histories and contain fluid inclusions that indicate that fluids cooled from between 260?? and 230??C to less than 200??C. Fluid boiling may have contributed to precious-metal deposition. Veins in both zones have relatively high As and Sb and low Bi, Te, and W. The silver zone has high Ca, Pb, Mn, Zn, Cd, Tl, and Se. The gold zone has high Hg and Mo. A few samples from an area of overlap between the two zones share chemical characteristics of both deposit types. The deposit types could represent a single zoned or evolving system in which hydrothermal fluids rose along structures within the silver zone, preferentially deposited Ag and base metals, and then spread into the gold zone. Alternatively, the deposit types could represent two distinct but temporally indistinguishable hydrothermal cells that only narrowly overlapped spatially. As noted in previous studies, the hydrothermal fluids that generated the Tuscarora and other epithermal deposits could have evolved from Carlin-type fluids by boiling and mixing with meteoric water. If so, the Tuscarora deposit may represent epithermal conditions above Carlin-type deposits, and Carlin-type deposits may lie beneath the district.
Analysis of County School Districts in Arkansas.
ERIC Educational Resources Information Center
Budd, Karol B.; Charlton, J.L.
The 1948, Arkansas School District Reorganization Act was passed in an effort to reduce the 1589 small school districts to a smaller number. Those districts not consolidated would form county districts. As of the 1967-68 school year, 26 of these county districts remained. The purpose of this study was to provide information drawing attention to…
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Boundaries: The Community Development District; The Dune District; The Seashore District. 28.3 Section 28.3 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR FIRE ISLAND NATIONAL SEASHORE: ZONING STANDARDS...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Boundaries: The Community Development District; The Dune District; The Seashore District. 28.3 Section 28.3 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR FIRE ISLAND NATIONAL SEASHORE: ZONING STANDARDS...
NASA Astrophysics Data System (ADS)
Yun, Seong-Taek; So, Chil-Sup; Choi, Sang-Hoon; Shelton, Kevin L.; Koo, Ja-Hak
1993-04-01
The Wolyu mine is one of the largest vein-type gold-silver-bearing epithermal systems in the Youngdong district and is the first gold-silver deposit in Korea found to contain significant germanium, in the form of argyrodite (Ag8GeS6). Mineralized veins (78.9 ± 1.2 Ma) crosscutting Late Cretaceous hostrock tuff and quartz porphyry (81.5 ± 1.8 Ma) consist of three stages of quartz and carbonates, the first of which contains pyrite, basemetal sulfides and Au-Ag-minerals. Stage I Au-Ag-Ge-mineralized veins show a systematic variation of mineral assemblage with time: (1) quartz + pyrite; (2) quartz + pyrite + sphalerite + electrum + argentite; (3) carbonate + quartz + sphalerite + electrum + argentite; (4) carbonate + native silver + argentite + Ag-sulfosalts + argyrodite + sphalerite. Calculated values of temperature and sulfur activity are: assemblage (1), 360-280°C and 10-7-10-10; (2), 280-210°C and 10-10-10-14; (3), 210-180°C and 10-14-10-16; (4), 180-155°C and 10-17-10-18. These data, the frequent association of gold with sulfides, and the abundance of pyrite in alteration zones indicate that decreasing sulfur activity and cooling were important in triggering gold deposition. Hydrogen and oxygen isotope compositions of ore fluids display a systematic variation with increasing time. Within the main Ag-Au-Ge mineralization, δD and δ 18O values decrease with the transition from quartz to carbonate deposition (from -78 and -2.8% to -90 and -8.7%., respectively), indicating increasing involvement (mixing) of less evolved meteoric water which resulted in progressive cooling and dilution of ore fluids in the shallow (≈ 370 600 m) Wolyu epithermal system.
Webber, K.L.; Falster, A.U.; Simmons, W.B.; Foord, E.E.
1997-01-01
The George Ashley Block (GAB), located in the Pala Pegmatite District, San Diego County, California, is a composite pegmatite-aplite dike of 8 m thickness displaying striking mineralogical layering in the aphte portion of the dike, referred to as line rock. Rhythmic layering is characterized by garnet-rich bands alternating with albite-quartz-muscovite-rich bands. Cumulus textures are notably absent from the layered portion of the dike. Elongated quartz, megacrysts are oriented perpendicular to the garnet-rich layers and poikilitically include garnet, albite, and muscovite. Calculated crystal-free magma viscosity with 3% H2O is 106.2 Pa s and the calculated settling velocity for garnet is 0??51 cm/year. Conductive cooling calculations based on emplacement of a 650??C dike into 150?? C fractured gabbroic country rock at 1??5 kbar, and accounting for latent heat of crystallization, demonstrate that the line rock portion of the dike cools to 550?? C in about 1 year. Crystal size distribution studies also suggest very rapid nucleation and crystallization. Diffusion-controlled gel crystallization experiments yield textures virtually identical to those observed in the layered aplite, including rhythmic banding, colloform layering, and band discontinuities. Thus, observed textures and calculated magmatic parameters suggest that mineralogical layering in the GAB results from an in situ diffusion-controlled process of oscillatory nucleation and crystallization. We propose that any event that promotes strong undercooling has the potential to initiate rapid heterogeneous nucleation and oscillatory crystal growth, leading to the development of a layer of excluded components in front of the crystallization front, and the formation of line rock.
ERIC Educational Resources Information Center
Dougherty, Chrys; Shaw, Teresa
2016-01-01
This report looks at student achievement levels in Arkansas school districts disaggregated by district poverty and by the district's performance relative to other districts. We estimated district performance statistics by subject and grade level (4, 8, and 11-12) for longitudinal student cohorts, using statistical models that adjusted for district…
Code of Federal Regulations, 2011 CFR
2011-07-01
... District Northwest Arctic Borough Southeast Fairbanks Election District Upper Yukon Election District Yukon... Election District Northwest Arctic Borough Southeast Fairbanks Election District Upper Yukon Election... Nome Census Area North Slope Borough Northwest Arctic Borough Southeast Fairbanks Census Area Yukon...
The Need for District Support for School Reform: What the Researchers Say. Research Brief.
ERIC Educational Resources Information Center
Appelbaum, Deborah
This article focuses on the school district's role in implementing Comprehensive School Reform (CSR). Research shows that effective district support for CSR varies from district to district. This is due, in part, to the fact that many prior models bypassed the district, operating under the belief that reform would be more effective if it targeted…
26 CFR 301.7514-1 - Seals of office.
Code of Federal Regulations, 2010 CFR
2010-04-01
... District Director for: Arkansas-Oklahoma District (Oklahoma City) Brooklyn District Central California...) Upstate New York District (Buffalo) Virginia-West Virginia District (Richmond) Office of Director of Computing Centers in: Detroit Memphis Martinsburg Office of Director of Submission Processing Centers in...
ERIC Educational Resources Information Center
Barker, Bruce O.; Muse, Ivan D.
A 1982-83 survey produced data used to compare 17 small/rural K-12 New Mexico school districts (900 students or fewer) with 642 similar districts nationwide. Of New Mexico's 88 school districts, 43 were identified as qualifying (48.9%, enrolling 16,648 students), for comparison to 4,125 similar districts nationwide. A questionnaire mailed to…
Peridotite-suite dominated mineral inclusions in diamonds from Kelsey Lake Mine, Colorado U.S.A.
NASA Astrophysics Data System (ADS)
Schulze, D. J.; Coopersmith, H. G.
2005-12-01
Thirty silicate and oxide inclusions large enough for in situ WDS electron microprobe analysis were exposed by grinding/polishing of 16 diamonds from the Kelsey Lake Mine in the Colorado-Wyoming State Line kimberlite district. Three garnets in two stones belong to the eclogite (E) suite, and 18 olivines, three Mg-chromites and six Cr-pyropes in the other 14 stones belong to the peridotite (P) suite. The peridotite-dominated population is in stark contrast to the other suites studied in the State Line district. The reported inclusion population from George Creek is completely eclogitic and that of the Sloan pipe is overwhelmingly eclogitic, with only a minor, relatively Fe-rich peridotite component. Multiple inclusions are common in single stones, with 12 olivines (of uniform composition) exposed in one example. Kelsey Lake olivine inclusions are magnesian (17 of 18 grains in 9 stones are in the range Fo 92.7-93.1), typical of P-suite stones worldwide, but unlike the more Fe-rich Sloan olivine suite (13 of 14 in the range Fo 91.3-92.2). Mg-chromites (wt percent MgO = 12.8-13.8, wt percent Cr2O3 = 61.4-66.6) are in the lower MgO range of diamond inclusion chromites worldwide. Six Cr-pyropes in four stones have moderately low calcium contents (wt percent CaO = 3.5-4.5) but are very Cr-rich (wt percent Cr2O3 = 10.5-16.7). An olivine-garnet pair in one stone yields a Mg-Fe exchange temperature of 895 degrees C, possibly indicating disequilibrium, whereas an olivine-chromite pair yields an Mg-Fe exchange temperature of 1035 degrees C, cool but reasonable for equilibration within the diamond stability field. Comparison with diamond inclusion minerals worldwide reveals that the Kesley Lake suite is most similar to those from the Slave Craton in Canada, especially in terms of Cr-pyrope compositions. Both suites are somewhat less depleted than suites from southern Africa or Siberian kimberlites. By analogy with the Slave P-suite diamonds of Archean age and a Proterozoic eclogitic component in the Slave mantle, the mixed diamond inclusion populations from the State Line district may support models in which blocks of Archean mantle survive buried beneath Proterozoic continental crust, mixed with eclogitic regimes emplaced by Proterozoic subduction.
Empowering High School Students in Scientific Careers: Developing Statewide Partnerships
NASA Astrophysics Data System (ADS)
Aguilar, C.; Swartz, D.
2008-05-01
Center for Multiscale Modeling of Atmospheric Processes (CMMAP) is a National Science Foundation Science and Technology Center focused on improving the representation of cloud processes in climate models. The Center is divided into three sections including Knowledge Transfer, Research, and Education and Diversity. The Science Education and Diversity mission is to educate and train people with diverse backgrounds in Climate and Earth System Science by enhancing teaching and learning and disseminating science results through multiple media. CMMAP is partnering with two local school districts to host an annual global climate conferences for high school students. The 2008 Colorado Global Climate Conference seeks "To educate students on global and local climate issues and empower them to se their knowledge." The conference is sponsored by CMMAP, The Governor's Energy Office, Poudre School District, Thompson School District, Clif Bar, and Ben and Jerry's Scoop Shop of Fort Collins. The conference seeks to inspire students to pursue future education and careers in science fields. Following an opening welcome from the Governor's Energy Office, Keynote Piers Sellers will discuss his experiences as an atmospheric scientist and NASA astronaut. Students will then attend 3 out of 16 breakout sessions including such sessions as "Hot poems, Cool Paintings, and the treasures of Antiquity of Climate Change", "Mitigation vs Adaptation", "Bigfoot Walks(What Size is our carbon footprint?)" "The Wedges: Reduc ing Carbon Emissions", and "We the People: Climate and Culture of Climate Change" to name a few. Using The Governor's High School Conference on the Environment sponsored by the Wisconsin Center for Environmental Education as a model we are developing statewide partnerships to bring high school students together to look at global climate issues that will impact their future and of which they can be part of the solution through their education and career paths. In addition to attending breakout sessions, students will participate in a Learning Fair where over 100 demonstrations and hands on experiments will be available from everything to "Making a Cloud in a Bottle" to "Making a Difference One Tea Bag at a Time." Students will also bring a poster to showcase their accomplishments in their own schools. The target audience is 400 high school students from across the state of Colorado, specifically targeting underserved populations such as students from rural areas, minority populations and students that are eligible for free and reduced lunch.
Bonenberger, Marc; Aikins, Moses; Akweongo, Patricia; Wyss, Kaspar
2016-01-14
There is increasing evidence that good district management practices can improve health system performance and conversely, that poor and inefficient management practices have detrimental effects. The aim of the present study was to identify factors contributing to inefficient management practices of district health managers and ways to improve their overall efficiency. Nineteen semi-structured interviews were conducted with district health managers in three districts of the Eastern Region in Ghana. The 19 interviews conducted comprised 90% of the managerial workforce in these districts in 2013. A thematic analysis was carried out using the WHO's leadership and management strengthening framework to structure the results. Key factors for inefficient district health management practices were identified to be: human resource shortages, inadequate planning and communication skills, financial constraints, and a narrow decision space that constrains the authority of district health managers and their ability to influence decision-making. Strategies that may improve managerial efficiency at both an individual and organizational level included improvements to planning, communication, and time management skills, and ensuring the timely release of district funds. Filling District Health Management Team vacancies, developing leadership and management skills of district health managers, ensuring a better flow of district funds, and delegating more authority to the districts seems to be a promising intervention package, which may result in better and more efficient management practices and stronger health system performance.
Turbine airfoil cooling system with cooling systems using high and low pressure cooling fluids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marsh, Jan H.; Messmann, Stephen John; Scribner, Carmen Andrew
A turbine airfoil cooling system including a low pressure cooling system and a high pressure cooling system for a turbine airfoil of a gas turbine engine is disclosed. In at least one embodiment, the low pressure cooling system may be an ambient air cooling system, and the high pressure cooling system may be a compressor bleed air cooling system. In at least one embodiment, the compressor bleed air cooling system in communication with a high pressure subsystem that may be a snubber cooling system positioned within a snubber. A delivery system including a movable air supply tube may be usedmore » to separate the low and high pressure cooling subsystems. The delivery system may enable high pressure cooling air to be passed to the snubber cooling system separate from low pressure cooling fluid supplied by the low pressure cooling system to other portions of the turbine airfoil cooling system.« less
Leadership Academies: A District Office Perspective
ERIC Educational Resources Information Center
Doll, Rick
2016-01-01
This article investigates district-level administrators' perceptions regarding the value of the partnership academies. The article uses input from seven district administrators who provided feedback regarding the value of the district and university partnership, specific benefits to the district, the differences between participants who envision…
ERIC Educational Resources Information Center
O'Connell, Patricia A.; And Others
This report presents the results of a collaborative study undertaken by five rural, unit school districts in Illinois to provide data to be used in planning for school improvement. Information was gathered from on-site visits by teams of constituents from other districts and through a survey of perceptions of local community persons regarding…
Microbial analysis of meatballs cooled with vacuum and conventional cooling.
Ozturk, Hande Mutlu; Ozturk, Harun Kemal; Koçar, Gunnur
2017-08-01
Vacuum cooling is a rapid evaporative cooling technique and can be used for pre-cooling of leafy vegetables, mushroom, bakery, fishery, sauces, cooked food, meat and particulate foods. The aim of this study was to apply the vacuum cooling and the conventional cooling techniques for the cooling of the meatball and to show the vacuum pressure effect on the cooling time, the temperature decrease and microbial growth rate. The results of the vacuum cooling and the conventional cooling (cooling in the refrigerator) were compared with each other for different temperatures. The study shows that the conventional cooling was much slower than the vacuum cooling. Moreover, the microbial growth rate of the vacuum cooling was extremely low compared with the conventional cooling. Thus, the lowest microbial growth occurred at 0.7 kPa and the highest microbial growth was observed at 1.5 kPa for the vacuum cooling. The mass loss ratio for the conventional cooling and vacuum cooling was about 5 and 9% respectively.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-05
... Metropolitan Air Quality Management District, San Joaquin Valley Unified Air Pollution Control District, and South Coast Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION... Air Pollution Control District (PCAPCD), Sacramento Metropolitan Air Quality Management District...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-05
... Metropolitan Air Quality Management District, San Joaquin Valley Unified Air Pollution Control District, and South Coast Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION... District (PCAPCD), Sacramento Metropolitan Air Quality Management District (SMAQMD), San Joaquin Valley...
NASA Astrophysics Data System (ADS)
Lee, Victor R.; Leary, Heather M.; Sellers, Linda; Recker, Mimi
2014-06-01
When introducing and implementing a new technology for science teachers within a school district, we must consider not only the end users but also the roles and influence district personnel have on the eventual appropriation of that technology. School districts are, by their nature, complex systems with multiple individuals at different levels in the organization who are involved in supporting and providing instruction. Varying levels of support for new technologies between district coordinators and teachers can sometimes lead to counterintuitive outcomes. In this article, we examine the role of the district science coordinator in five school districts that participated in the implementation of an online resource discovery and sharing tool for Earth science teachers. Using a qualitative approach, we conducted and coded interviews with district coordinators and teachers to examine the varied responsibilities associated with the district coordinator and to infer the relationships that were developed and perceived by teachers. We then examine and discuss two cases that illustrate how those relationships could have influenced how the tool was adopted and used to differing degrees in the two districts. Specifically, the district that had high support for online resource use from its coordinator appeared to have the lowest level of tool use, and the district with much less visible support from its coordinator had the highest level of tool use. We explain this difference in terms of how the coordinator's promotion of teacher autonomy took distinctly different forms at those two districts.
Michael, Shannon; Brener, Nancy D.; Coffield, Edward; Kingsley, Beverly S.; Zytnick, Deena; Blanck, Heidi
2016-01-01
Introduction Foods and beverages marketed in schools are typically of poor nutritional value. School districts may adopt policies and practices to restrict marketing of unhealthful foods and to promote healthful choices. Students’ exposure to marketing practices differ by school demographics, but these differences have not yet been examined by district characteristics. Methods We analyzed data from the 2012 School Health Policies and Practices Study to examine how food and beverage marketing and promotion policies and practices varied by district characteristics such as metropolitan status, size, and percentage of non-Hispanic white students. Results Most practices varied significantly by district size: a higher percentage of large districts than small or medium-sized districts restricted marketing of unhealthful foods and promoted healthful options. Compared with districts whose student populations were majority (>50%) non-Hispanic white, a higher percentage of districts whose student populations were minority non-Hispanic white (≤50% non-Hispanic white) prohibited advertising of soft drinks in school buildings and on school grounds, made school meal menus available to students, and provided families with information on school nutrition programs. Compared with suburban and rural districts, a higher percentage of urban districts prohibited the sale of soft drinks on school grounds and used several practices to promote healthful options. Conclusion Preliminary findings showing significant associations between district demographics and marketing policies and practices can be used to help states direct resources, training, and technical assistance to address food and beverage marketing and promotion to districts most in need of improvement. PMID:27978408
Merlo, Caitlin L; Michael, Shannon; Brener, Nancy D; Coffield, Edward; Kingsley, Beverly S; Zytnick, Deena; Blanck, Heidi
2016-12-15
Foods and beverages marketed in schools are typically of poor nutritional value. School districts may adopt policies and practices to restrict marketing of unhealthful foods and to promote healthful choices. Students' exposure to marketing practices differ by school demographics, but these differences have not yet been examined by district characteristics. We analyzed data from the 2012 School Health Policies and Practices Study to examine how food and beverage marketing and promotion policies and practices varied by district characteristics such as metropolitan status, size, and percentage of non-Hispanic white students. Most practices varied significantly by district size: a higher percentage of large districts than small or medium-sized districts restricted marketing of unhealthful foods and promoted healthful options. Compared with districts whose student populations were majority (>50%) non-Hispanic white, a higher percentage of districts whose student populations were minority non-Hispanic white (≤50% non-Hispanic white) prohibited advertising of soft drinks in school buildings and on school grounds, made school meal menus available to students, and provided families with information on school nutrition programs. Compared with suburban and rural districts, a higher percentage of urban districts prohibited the sale of soft drinks on school grounds and used several practices to promote healthful options. Preliminary findings showing significant associations between district demographics and marketing policies and practices can be used to help states direct resources, training, and technical assistance to address food and beverage marketing and promotion to districts most in need of improvement.
ERIC Educational Resources Information Center
Dessoff, Alan
2009-01-01
It's no surprise that school districts are as vulnerable to fraud as the private sector or any other segment of government. Crimes in districts include collusion with outside vendors who provide kickbacks to employees, misuse of district-issued credit cards, embezzlement of district funds, and theft of district property. "Fraud happens…
20 CFR 702.272 - Informal recommendation by district director.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Informal recommendation by district director... Procedures Discrimination § 702.272 Informal recommendation by district director. (a) If the district... employee accept the district director's recommendation, it will be incorporated in an order and mailed to...
22 CFR 92.3 - Consular districts.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Consular districts. 92.3 Section 92.3 Foreign Relations DEPARTMENT OF STATE LEGAL AND RELATED SERVICES NOTARIAL AND RELATED SERVICES Introduction § 92.3 Consular districts. Where consular districts have been established, the geographic limits of the district...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... Municipal Air Quality Management District and South Coast Air Quality Management District AGENCY... Quality Management District (SMAQMD) and South Coast Air Quality Management District (SCAQMD) portions of...,'' revised September 20, 2010. (D) Sacramento Metropolitan Air Quality Management District. (1) Rule 466...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... Municipal Air Quality Management District and South Coast Air Quality Management District AGENCY... the Santa Barbara Air Pollution Control District (SBAPCD), Sacramento Municipal Air Quality Management District (SMAQMD) and South Coast Air Quality Management District (SCAQMD) portions of the California State...
7 CFR 932.129 - Nomination procedures for producer members.
Code of Federal Regulations, 2010 CFR
2010-01-01
... producers) who produced olives within the district shall participate in the nomination and election of... district may participate in nominations and elections in only one district. The district in which the... each odd-numbered year, in each producing district for the purpose of selecting candidates for member...
7 CFR 1206.30 - Establishment and membership.
Code of Federal Regulations, 2011 CFR
2011-01-01
... INFORMATION Mango Promotion, Research, and Information Order Definitions National Mango Promotion Board § 1206... on the volume of mangos imported into the Customs Districts identified by their name and Code Number... seats for District I, three seats for District II, two seats for District III, and one seat for District...
Making the Grade in America's Cities: Assessing Student Achievement in Urban Districts
ERIC Educational Resources Information Center
Blagg, Kristin
2016-01-01
Many US education reform efforts focus on student performance in large, urban school districts. The National Assessment of Educational Progress's Trial Urban District Assessment (TUDA) program provides data on student achievement in these districts, but differences in student characteristics complicate comparisons of district performance. I use…
Drawing the Line: Student Reassignment Policies in South Carolina
ERIC Educational Resources Information Center
Simmons, Naomi Rachel
2013-01-01
This study investigates the complex nature of student reassignment plans developed between 2006 and 2008 in three South Carolina school districts: York School District 3, Dorchester School District 2, and Greenville School District. The study is guided by the following research question: How are the district policies for student reassignment…
An Analysis of a High Performing School District's Culture
ERIC Educational Resources Information Center
Corum, Kenneth D.; Schuetz, Todd B.
2012-01-01
This report describes a problem based learning project focusing on the cultural elements of a high performing school district. Current literature on school district culture provides numerous cultural elements that are present in high performing school districts. With the current climate in education placing pressure on school districts to perform…
The Relationship of Rurality and Education Accountability Outcomes.
ERIC Educational Resources Information Center
Peevely, Gary; Ray, John R.
This paper examines accountability outcomes of Tennessee school districts, comparing rural versus urban districts and litigant versus nonlitigant districts from a 1993 fiscal equity lawsuit. School districts were assigned a measure of rurality using the Cleland Rurality Index, and comparisons were made among the 29 low-rurality districts, 66…
Code of Federal Regulations, 2011 CFR
2011-01-01
... law for the express purpose of developing and carrying out a local soil and water conservation program. Such district or unit of government may be referred to as a “conservation district,” “soil conservation district,” “soil and water conservation district,” “resource conservation district,” “natural resource...
1986-06-19
deputy chairman. 74. Vidin Electoral District. Kiril Dimitrov Zarev, BCP Central Committee secretary. 75. Vidin Electoral District. Georgi Vulkanov...Blagoevgrad. 4. Simitli Electoral District. Boris Dimitrov Karanfilov, BCP Central Committee member, deputy minister of national defense. 5. Strumyan...Electoral District. Emiliya Mircheva Kostova, chairman okrug BZNS management. 6. Sandanski Electoral District. Lalyu Ivanov Dimitrov , BCP Central
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-21
... of the Louisville Metro Air Pollution Control District (District), which has jurisdiction over... County Air Pollution Control District'' was renamed the ``Louisville Metro Air Pollution Control District... subheading ``Air Pollution Control District of Jefferson County.'' Thus, to be consistent with the...
Systematic Research and Evaluation in a Rural Pennsylvania School District.
ERIC Educational Resources Information Center
Leopold, Greg; And Others
This report summarizes the evaluation of a rural school district in Pennsylvania and offers recommendations reflecting the district's goals for school improvement and construction. Specifically, the objectives of the study were to identify curricular needs of the district and individual schools; review and assess district facilities with respect…
School District Mergers: What One District Learned
ERIC Educational Resources Information Center
Kingston, Kathleen
2009-01-01
Throughout the planning process for a school district merger in a northwestern Pennsylvania school district, effective communication proved to be a challenge. Formed in 1932, this school district of approximately 1400 students was part of a utopian community; one established by a transportation system's corporation that was a major industrial…
Scaling and Multifractality in Road Accidental Distances
NASA Astrophysics Data System (ADS)
Qiu, Tian; Wan, Chi; Zou, Xiang-Xiang; Wang, Xiao-Fan
Accidental distance dynamics is investigated, based on the road accidental data of the Great Britain. The distance distribution of all the districts as an ensemble presents a power law tail, which is different from that of the individual district. A universal distribution is found for different districts, by rescaling the distribution functions of individual districts, which can be well fitted by the Weibull distribution. The male and female drivers behave similarly in the distance distribution. The multifractal characteristic is further studied for the individual district and all the districts as an ensemble, and different behaviors are also revealed between them. The accidental distances of the individual district show a weak multifractality, whereas of all the districts present a strong multifractality when taking them as an ensemble.
Arp, Christopher D.; Jones, Benjamin M.
2009-01-01
Lakes are abundant landforms and important ecosystems in Alaska, but are unevenly distributed on the landscape with expansive lake-poor regions and several lake-rich regions. Such lake-rich areas are termed lake districts and have landscape characteristics that can be considered distinctive in similar respects to mountain ranges. In this report, we explore the nature of lake-rich areas by quantitatively identifying Alaska's lake districts, describing and comparing their physical characteristics, and analyzing how Alaska lake districts are naturally organized and correspond to climatic and geophysical characteristics, as well as studied and managed by people. We use a digital dataset (National Hydrography Dataset) of lakes greater than 1 hectare, which includes 409,040 individual lakes and represents 3.3 percent of the land-surface area of Alaska. The selection criteria we used to identify lake districts were (1) a lake area (termed limnetic ratio, in percent) greater than the mean for the State, and (2) a lake density (number of lakes per unit area) greater than the mean for the State using a pixel size scaled to the area of interest and number of lakes in the census. Pixels meeting these criteria were grouped and delineated and all groups greater than 1,000 square kilometers were identified as Alaska's lake districts. These lake districts were described according to lake size-frequency metrics, elevation distributions, geology, climate, and ecoregions to better understand their similarities and differences. We also looked at where lake research and relevant ecological monitoring has occurred in Alaska relative to lake districts and how lake district lands and waters are currently managed. We identified and delineated 20 lake districts in Alaska representing 16 percent of the State, but including 65 percent of lakes and 75 percent of lake area. The largest lake districts identified are the Yukon-Kuskokwim Delta, Arctic Coastal Plain, and Iliamna lake districts with high limnetic ratios of 19, 17, and 21 percent, respectively. The three smallest districts we considered were Tetlin in the eastern interior, Menhiskof on the Alaska Peninsula, and Matanuska-Susitna at the head of Cook Inlet with limnetic ratios of 14, 9, and 9 percent, respectively. Lake density and limnetic ratio were poorly related among lake districts, such that some districts had a few large lakes like Iliamna with Lakes Iliamna and Becharof - the two largest in the State, compared to other districts with many very small lakes like Yukon-Kuskokwim Delta with 111,130 lakes and 63 percent of these less than 10 hectares. Most lake districts are in regions with relatively low precipitation, but temperature regimes varied widely among lake districts. Approximately one-half of lake districts were glaciated during the Pleistocene and similar numbers occur in regions classified as having continuous, discontinuous, and sporadic permafrost, or perennially unfrozen soils. Most districts are at low elevations (less than 250 meters) with two important exceptions being Tetlin with a mean elevation of 530 meters and Ahtna with a mean elevation of 760 meters. These higher elevation districts, particularly Ahtna, had distinct characteristics from other lake districts such as continuous permafrost and Pleistocene glaciation. Several lake districts share similar boundaries to defined ecoregions with lake districts occurring in less than one-half of these 32 ecoregions of Alaska. Most lake districts are lands fully or partly managed by the U.S. Fish and Wildlife Service and the National Park Service, with other land management by the Bureau of Land Management and State and borough government. Much of the U.S. Geological Survey's lake water-quality sampling efforts has been done in the Arctic Coastal Plain, Matanuska-Susitna, and Iliamna districts but no recorded collections in nine lake districts. Similarly, most lake limnological studies in Alaska were site-specific an
Split radiator design for heat rejection optimization for a waste heat recovery system
Ernst, Timothy C.; Nelson, Christopher R.
2016-10-18
A cooling system provides improved heat recovery by providing a split core radiator for both engine cooling and condenser cooling for a Rankine cycle (RC). The cooling system includes a radiator having a first cooling core portion and a second cooling core portion. An engine cooling loop is fluidly connected the second cooling core portion. A condenser of an RC has a cooling loop fluidly connected to the first cooling core portion. A valve is provided between the engine cooling loop and the condenser cooling loop adjustably control the flow of coolant in the condenser cooling loop into the engine cooling loop. The cooling system includes a controller communicatively coupled to the valve and adapted to determine a load requirement for the internal combustion engine and adjust the valve in accordance with the engine load requirement.
Accountability and Educational Equity in the Transformation of an Urban District.
ERIC Educational Resources Information Center
Koschoreck, James W.
2001-01-01
Highlights how one Texas school district moved from being a district in which token representations of minority achievement were considered evidence of districtwide success to being a district where success for all children is the operating paradigm. Guided by vision, culture, and district support, teachers have raised student achievement levels…
Technology Finds Its Place in Silicon Valley Schools
ERIC Educational Resources Information Center
Hundley, Paula; Scigliano, Marie
2012-01-01
Technology today is poised to usher in the best of times. Exploring what other districts do highlights the common themes as well as the unique challenges. Three very different districts in Silicon Valley--Portola Valley School District, Campbell Union School District and San Jose Unified School District--explain the strategies they use to enhance…
46 CFR 4.07-25 - Testimony of witnesses in other districts, depositions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Testimony of witnesses in other districts, depositions... other districts, depositions. When witnesses are available in a district other than the district in... conducting the investigation. Depositions may be taken in the manner prescribed by regulations in subpart 4...
School District Personnel Describe One Example of Effective Change Implementation.
ERIC Educational Resources Information Center
Jones, Toni Griego
Three large urban school districts located in the Midwest, Southwest, and West Coast regions were involved in a study designed to reveal district personnel's perceptions of change within their school district. After describing the study, this document analyzes perceptions of change related to one district's new bilingual program that was…
The Fiscal Condition of School Districts in Nebraska: Is Small Beautiful?
ERIC Educational Resources Information Center
Ratcliffe, Kerri; And Others
1990-01-01
Using a methodology previously applied to municipalities, this paper examines the fiscal condition of Nebraska's school districts. Nebraska contains over 900 districts, ranging from very small to large full-service districts in Lincoln and Omaha. The largest and smallest districts are in best fiscal condition. State aid inequities could be…
Analysis of Superintendent Longevity in Large School Districts: A Qualitative Study
ERIC Educational Resources Information Center
Mouton, Nikki Golar
2013-01-01
School district leadership matters, as evidenced by a meta-analysis of 27 reports and 1,210 districts conducted by Waters and Marzano (2006) which highlights a statistically significant correlation between district leadership and student achievement. Because this relationship is significant, it is important for school districts to have effective…
School District Employment Reductions Slow. Get the Facts. #1
ERIC Educational Resources Information Center
Tallman, Mark
2012-01-01
Kansas school districts reduced employment by 327 full-time equivalent positions this school year, the smallest reduction in three years of cuts to district operating budgets. Districts reduced positions by 561 in FY 2010 and 1,626 in FY 2011. Districts eliminated nearly 400 "regular" teaching positions this year, but added 114 special…
30 CFR 71.301 - Respirable dust control plan; approval by District Manager and posting.
Code of Federal Regulations, 2010 CFR
2010-07-01
... District Manager and posting. 71.301 Section 71.301 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... plan; approval by District Manager and posting. (a) The District Manager will approve respirable dust control plans on a mine-by-mine basis. When approving respirable dust control plans, the District Manager...
46 CFR 50.10-5 - Coast Guard District Commander or District Commander.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Coast Guard District Commander or District Commander. 50.10-5 Section 50.10-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS Definition of Terms Used in This Subchapter § 50.10-5 Coast Guard District...
Preschool Guidelines: Rural Model (Trimble Local School District).
ERIC Educational Resources Information Center
Ohio State Dept. of Education, Columbus. Div. of Educational Services.
The purpose of this handbook is to guide rural school districts intending to establish a preschool program. The program described was established in the Trimble Local School District in the rural Appalachian area of northern Athens County, the third poorest district in Ohio. Contents concern: (1) the district's beliefs about children; (2)…
Small Districts in Big Trouble: How Four Arizona School Systems Responded to Charter Competition.
ERIC Educational Resources Information Center
Hess, Frederick; Maranto, Robert; Milliman, Scott
2001-01-01
Examined the responses to charter school competition of four small Arizona school districts. Overall, districts lost students to charter schools because they did not satisfy significant constituencies. Their responses depended on overall enrollment trends, quality of charter competition, quality of district leadership, and district size. Responses…
Jung, Sunyoung
2008-01-01
Objectives. We examined the association between county-level estimates of children's health status and school district performance in California. Methods. We used 3 data sources: the California Health Interview Survey, district archives from the California Department of Education, and census-based estimates of county demographic characteristics. We used logistic regression to estimate whether a school district's failure to meet adequate yearly progress goals in 2004 to 2005 was a function of child and adolescent's health status. Models included district- and county-level fixed effects and were adjusted for the clustering of districts within counties. Results. County-level changes in children's and adolescent's health status decreased the likelihood that a school district would fail to meet adequate yearly progress goals during the investigation period. Health status did not moderate the relatively poor performance of predominantly minority districts. Conclusions. We found empirical support that area variation in children's and adolescent's health status exerts a contextual effect on school district performance. Future research should explore the specific mechanisms through which area-level child health influences school and district achievement. PMID:18309137
NASA Astrophysics Data System (ADS)
Ma, Libin; Ren, Jianxing
2018-01-01
Large capacity and super large capacity thermal power is becoming the main force of energy and power industry in our country. The performance of cooling tower is related to the water temperature of circulating water, which has an important influence on the efficiency of power plant. The natural draft counter flow wet cooling tower is the most widely used cooling tower type at present, and the high cooling tower is a new cooling tower based on the natural ventilation counter flow wet cooling tower. In this paper, for high cooling tower, the application background of high cooling tower is briefly explained, and then the structure principle of conventional cooling tower and high cooling tower are introduced, and the difference between them is simply compared. Then, the influence of crosswind on cooling performance of high cooling tower under different wind speeds is introduced in detail. Through analysis and research, wind speed, wind cooling had little impact on the performance of high cooling tower; wind velocity, wind will destroy the tower inside and outside air flow, reducing the cooling performance of high cooling tower; Wind speed, high cooling performance of cooling tower has increased, but still lower than the wind speed.
Water withdrawals in Florida, 2012
Marella, Richard L.
2015-09-01
The largest percentage of freshwater withdrawals was from the South Florida Water Management District (46 percent), followed by the St. Johns River Water Management District (20 percent), Southwest Florida Water Management District (19 percent), Northwest Florida Water Management District (9 percent), and Suwannee River Water Management District (6 percent). The South Florida Water Management District accounted for the largest percentage of freshwater withdrawals for public-supply use (46 percent), commercial-industrial-mining self-supplied use (24 percent), agricultural self-supplied use (59 percent), and recreational-landscape irrigation use (63 percent). The Northwest Florida Water Management District accounted for the largest percentage of freshwater withdrawals for power-generation use (44 percent), and the Southwest Florida Water Management District accounted for the largest percentage of saline-water withdrawals for power-generation use (58 percent).
Merlo, Caitlin L; Michael, Shannon; Brener, Nancy D; Blanck, Heidi
2018-06-07
State agencies play a critical role in providing school districts with guidance and technical assistance on school nutrition issues, including food and beverage marketing practices. We examined associations between state-level guidance and the policies and practices in school districts regarding food and beverage marketing and promotion. State policy guidance was positively associated with districts prohibiting advertisements for junk food or fast food restaurants on school property. Technical assistance from states was negatively associated with 2 district practices to restrict marketing of unhealthy foods and beverages, but positively associated with 1 practice to promote healthy options. These findings may help inform the guidance that states provide to school districts and help identify which districts may need additional assistance to address marketing and promotion practices.
District wellness policies and school-level practices in Minnesota, USA.
Larson, Nicole; Davey, Cynthia; Hoffman, Pamela; Kubik, Martha Y; Nanney, Marilyn S
2016-01-01
To compare the strength of district wellness policies with corresponding school-level practices reported by principals and teachers. District-level wellness policy data were collected from school district websites and, if not available online, by requests made to district administrators in the autumn of 2013. The strength of district policies was scored using the Wellness School Assessment Tool. School-level data were drawn from the 2012 Minnesota School Health Profiles principal and teacher surveys and the National Center for Education Statistics Common Core Data. Generalized estimating equations which accounted for school-level demographics and the nesting of up to two schools within some districts were used to examine ten district policy items and fourteen school-level practices of relevance to nutrition standards, nutrition education and wellness promotion, and physical activity promotion. State-wide sample of 180 districts and 212 public schools in Minnesota, USA. The mean number of energy-dense, nutrient-poor snack foods and beverages available for students to purchase at school was inversely related to the strength of district wellness policies regulating vending machines and school stores (P=0·01). The proportion of schools having a joint use agreement for shared use of physical activity facilities was inversely related to the strength of district policies addressing community use of school facilities (P=0·03). No associations were found between the strength of other district policies and school-level practices. Nutrition educators and other health professionals should assist schools in periodically assessing their wellness practices to ensure compliance with district wellness policies and environments supportive of healthy behaviours.
District wellness policies and school-level practices in Minnesota
Larson, Nicole; Davey, Cynthia; Hoffman, Pamela; Kubik, Martha Y.; Nanney, Marilyn S.
2015-01-01
Objective To compare the strength of district wellness policies with corresponding school-level practices reported by principals and teachers. Design District-level wellness policy data was collected from school district websites and, if not available online, by requests made to district administrators in the fall of 2013. The strength of district policies was scored using the Wellness School Assessment Tool. School-level data were drawn from the 2012 Minnesota School Health Profiles principal and teacher surveys and National Center for Education Statistics Common Core Data. Generalized estimating equations which accounted for school-level demographics and the nesting of up to two schools within some districts were used to examine 10 district policy items and 14 school-level practices of relevance to nutrition standards, nutrition education and wellness promotion, and physical activity promotion. Setting/Subjects Statewide sample of 180 districts and 212 public schools in Minnesota. Results The mean number of energy-dense, nutrient-poor snack foods and beverages available for students to purchase at school was inversely related to the strength of district wellness policies regulating vending machines and school stores (p=0.01). The proportion of schools having a joint use agreement for shared use of physical activity facilities was inversely related to the strength of district policies addressing community use of school facilities (p=0.03). No associations were found between the strength of other district policies and school-level practices. Conclusions Nutrition educators and other health professionals should assist schools in periodically assessing their wellness practices to ensure compliance with district wellness policies and environments supportive of healthy behaviors. PMID:25990324
Exploring the ethos of district nursing, 1885-1985.
Madsen, Wendy
2013-06-01
The history of district nursing in Australia explored in this paper reveals a continuity in the essential values held by district nurses for over a century. These nurses practised holistic, family-centred nursing from the very origins of district nursing service. The events surrounding the establishment of Community Health Centres in the 1970s challenged district nurses to reconsider their role, while at the same time reconfirming their essential ethos. These values that underpinned district nursing practice and challenges to these values are examined in this paper.
Compatible poliomyelitis cases in India during 2000.
Kohler, Kathryn A.; Hlady, W. Gary; Banerjee, Kaushik; Gupta, Dhananjoy; Francis, Paul; Durrani, Sunita; Zuber, Patrick L. F.; Sutter, Roland W.
2003-01-01
OBJECTIVE: To describe the characteristics of compatible poliomyelitis cases and to assess the programmatic implications of clusters of such cases in India. METHODS: We described the characteristics of compatible poliomyelitis cases, identified clusters of compatible cases (two or more in the same district or neighbouring districts within two months), and examined their relationship to wild poliovirus cases. FINDINGS: There were 362 compatible cases in 2000. The incidence of compatible cases was higher in districts with laboratory-confirmed poliomyelitis cases than in districts without laboratory-confirmed cases. Of 580 districts, 96 reported one compatible case and 72 reported two or more compatible cases. Among these 168 districts with at least one compatible case, 123 had internal or cross- border clusters of compatible cases. In 27 districts with clusters of compatible cases, no wild poliovirus was isolated either in the same district or in neighbouring districts. Three of these 27 districts presented laboratory-confirmed poliomyelitis cases during 2001. CONCLUSION: Most clusters of compatible cases occurred in districts identified as areas with continuing wild poliovirus transmission and where mopping-up vaccination campaigns were carried out. As certification nears, areas with compatible poliomyelitis cases should be investigated and deficiencies in surveillance should be corrected in order to ensure that certification is justified. PMID:12640469
Code of Federal Regulations, 2012 CFR
2012-01-01
... III of the Bankhead-Jones Farm Tenant Act (7 U.S.C. 1011). (c) Watershed plan. A plan agreed upon by..., irrigation districts, drainage districts, flood prevention and control districts, school districts, other...
Code of Federal Regulations, 2013 CFR
2013-01-01
... III of the Bankhead-Jones Farm Tenant Act (7 U.S.C. 1011). (c) Watershed plan. A plan agreed upon by..., irrigation districts, drainage districts, flood prevention and control districts, school districts, other...
Code of Federal Regulations, 2014 CFR
2014-01-01
... III of the Bankhead-Jones Farm Tenant Act (7 U.S.C. 1011). (c) Watershed plan. A plan agreed upon by..., irrigation districts, drainage districts, flood prevention and control districts, school districts, other...
Reforming Districts: How Districts Support School Reform. A Research Report. Document R-03-6
ERIC Educational Resources Information Center
McLaughlin, Milbrey; Talbert, Joan
2003-01-01
School districts have participated in multiple rounds of education reform activity in the past few decades, yet few have made headway on system-wide school improvement. This paper addresses the questions of whether districts matter for school reform progress and what successful "reforming" districts do to achieve system change and to…
ERIC Educational Resources Information Center
Santoro, Elizabeth A.
2011-01-01
This qualitative study explored the reasons why suburban district leaders opted for full-day or half-day kindergarten programming in a sample of four local suburban districts operating such programs in Southeastern, Pennsylvania. The primary data source was interviews with key district leaders including school board members, superintendents,…
30 CFR 90.301 - Respirable dust control plan; approval by District Manager; copy to part 90 miner.
Code of Federal Regulations, 2010 CFR
2010-07-01
... District Manager; copy to part 90 miner. 90.301 Section 90.301 Mineral Resources MINE SAFETY AND HEALTH... control plan; approval by District Manager; copy to part 90 miner. (a) The District Manager will approve... District Manager shall consider whether: (1) The respirable dust control measures would be likely to...
The Role of the Superintendent in Closing the Achievement Gap in Diverse Small School Districts
ERIC Educational Resources Information Center
Wright, Howell, Jr.; Harris, Sandra
2010-01-01
The purpose of this qualitative, narrative study was to investigate the role of the superintendent in leading the district to be more culturally proficient, resulting in the narrowing of the achievement gap in culturally diverse small districts. Eight superintendents of small school districts were purposefully selected based on their district size…
From Districts to Schools: The Distribution of Resources across Schools in Big City School Districts
ERIC Educational Resources Information Center
Rubenstein, Ross; Schwartz, Amy Ellen; Stiefel, Leanna; Amor, Hella Bel Hadj
2007-01-01
While the distribution of resources across school districts is well studied, relatively little attention has been paid to how resources are allocated to individual schools inside those districts. This paper explores the determinants of resource allocation across schools in large districts based on factors that reflect differential school costs or…
ERIC Educational Resources Information Center
Moore, Glenn M.
2012-01-01
Purpose and Method of Study. The primary purpose of this quantitative study was to analyze the relationship between school district expenditures and student academic achievement in 102 public elementary school districts in the state of Oklahoma. The secondary purpose was to investigate the relationship between school district expenditures and…
ERIC Educational Resources Information Center
Wiener, Steve
Soaring values of agricultural land have created inequities in funding between urban and rural school districts in Minnesota. The state's Foundation Aid to school districts is formulated so that districts of high property valuation receive less Foundation Aid than those districts with low property valuation. In recent years inflation has had…
Land Acquisition Practices of the Miami-Dade County School District. Special Review.
ERIC Educational Resources Information Center
Florida State Legislature, Tallahassee. Office of Program Policy Analysis and Government Accountability.
This review, requested by the Florida Legislature, answers six questions about Miami-Dade County School District's land acquisition practices. The six questions are: (1) Does the district effectively identify its facility needs and plan for those needs? (2) Does the district acquire the land it needs? (3) Has the district adopted land acquisition…
33 CFR 3.40-1 - Eighth district.
Code of Federal Regulations, 2010 CFR
2010-07-01
... District § 3.40-1 Eighth district. (a) The District Office is in New Orleans, La. (b) The Eighth Coast..., Missouri, Kentucky, West Virginia, Tennessee, Arkansas, Oklahoma, New Mexico, Texas, Louisiana, Mississippi...
Effectiveness-weighted control method for a cooling system
Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth Jr., Michael J.; Iyengar, Madhusudan K.; Schmidt, Roger R.; Simons, Robert E.
2015-12-15
Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.
Effectiveness-weighted control of cooling system components
Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth Jr., Michael J.; Iyengar, Madhusudan K.; Schmidt, Roger R.; Simmons, Robert E.
2015-12-22
Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.
Quantitative data analysis to determine best food cooling practices in U.S. restaurants.
Schaffner, Donald W; Brown, Laura Green; Ripley, Danny; Reimann, Dave; Koktavy, Nicole; Blade, Henry; Nicholas, David
2015-04-01
Data collected by the Centers for Disease Control and Prevention (CDC) show that improper cooling practices contributed to more than 500 foodborne illness outbreaks associated with restaurants or delis in the United States between 1998 and 2008. CDC's Environmental Health Specialists Network (EHS-Net) personnel collected data in approximately 50 randomly selected restaurants in nine EHS-Net sites in 2009 to 2010 and measured the temperatures of cooling food at the beginning and the end of the observation period. Those beginning and ending points were used to estimate cooling rates. The most common cooling method was refrigeration, used in 48% of cooling steps. Other cooling methods included ice baths (19%), room-temperature cooling (17%), ice-wand cooling (7%), and adding ice or frozen food to the cooling food as an ingredient (2%). Sixty-five percent of cooling observations had an estimated cooling rate that was compliant with the 2009 Food and Drug Administration Food Code guideline (cooling to 41 °F [5 °C] in 6 h). Large cuts of meat and stews had the slowest overall estimated cooling rate, approximately equal to that specified in the Food Code guideline. Pasta and noodles were the fastest cooling foods, with a cooling time of just over 2 h. Foods not being actively monitored by food workers were more than twice as likely to cool more slowly than recommended in the Food Code guideline. Food stored at a depth greater than 7.6 cm (3 in.) was twice as likely to cool more slowly than specified in the Food Code guideline. Unventilated cooling foods were almost twice as likely to cool more slowly than specified in the Food Code guideline. Our data suggest that several best cooling practices can contribute to a proper cooling process. Inspectors unable to assess the full cooling process should consider assessing specific cooling practices as an alternative. Future research could validate our estimation method and study the effect of specific practices on the full cooling process.
NASA Astrophysics Data System (ADS)
Isava, V.; Grove, M.; Mahoney, J. B.; Kimbrough, D. L.
2016-12-01
The Late Cretaceous-Early Paleogene Nanaimo Group covers the contact between Triassic basement Wrangellia terrane and the Jurassic-Cretaceous Coast Plutonic Complex (CPC) in southern British Columbia. Prior detrital zircon U-Pb and Hf studies indicate a change in sediment source for the Nanaimo basin, from the primitive CPC in Santonian-Early Campanian time to an isotopically evolved continental extraregional source during the late Campanian/Maastrictian. Two notably different areas have been proposed as potential source regions: (1) the Idaho/Boulder batholith and Belt Supergroup, and (2) the Mojave/Salinia segment of structurally disrupted late Cretaceous southern California margin. Single crystal 40Ar/39Ar laser fusion of ca. 100-200 grains apiece from seven detrital K-feldspar samples from Santonian-Maastrichtian strata of the northern Nanaimo Group constrain the history of the sediments' source regions. The two oldest samples, from the K-feldspar poor Comox and Extension Fms., display a monotonic increasing distribution of cooling ages 80-125 Ma that reflects shallow erosion of the CPC. In contrast, Late Campanian strata of the Cedar District and De Courcy Fms. exhibit a more pronounced cluster of cooling ages 80-95 Ma as well as a greater proportion of Jurassic ages that represent progressively deeper erosion of the CPC. Evidence for an extraregional sediment source appears abruptly in the Geoffrey Fm. by 72 Ma, matching the time of local-to-extraregional shift indicated in detrital zircon U-Pb studies. Over 90% of the detrital K-feldspars from these arkosic sandstones yield cooling ages of 70-80 Ma, with sparse older ages associated with the CPC. Samples from the successively younger Spray and Gabriola Fms. also yield >90% K-feldspar ages younger than 80 Ma and exhibit age maxima of 68 Ma and 65 Ma, respectively. These results are distinct from detrital zircon U-Pb and K-feldspar 40Ar/39Ar ages of the southern Sierra Nevada, Mojave/Salina, and northern Peninsular Ranges of southern California. Resemblance with the Idaho/Boulder batholith indicates the latter as a more likely source of extraregional detritus. Measurements are underway to couple detrital K-feldspar 40Ar/39Ar thermochronology with U-Pb isotopes on the same grains to further distinguish between these two possibilities.
77 FR 65905 - Meeting of the California Desert District Advisory Council
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-31
... updates by council members, the BLM California Desert District manager, five field office managers, and...) 697-5220. Dated: October 23, 2012. Teresa A. Raml, District Manager, California Desert District. [FR...
Kendziora, Kimberly; Osher, David
2016-01-01
This article contributes to the broader discussion of promotion, prevention, and intervention in child and adolescent mental health by describing implementation and early outcomes of an 8-school district demonstration project aimed at making the promotion of social and emotional learning a systemic part of school districts' practice. Eight districts are 2-3 years in to their participation in the 6-year project. The districts are large, are predominantly urban, and serve many students who are at disadvantage. The evaluation involved collection of qualitative data to measure the degree to which the districts realized the goals established in the initiative's theory of action, as well as school climate data, extant student records, and surveys of students' social and emotional competence. To date, results show that districts have followed highly individual pathways toward integrating social and emotional learning systemically, and all have made progress over time. Although school-level implementation remains at moderate levels, 2 districts in which we could examine school climate showed gains from preinitiative years. Four of 6 measured districts showed improvement in social and emotional competence for students in Grade 3, and achievement and discipline showed overall improvements across all districts. Overall findings show that implementation of the initiative's theory of action by school districts is feasible, even in times of budgetary stress and leadership turnover. This establishes the potential for school districts to serve as a lever of change in the promotion of students' social and emotional development and mental wellness.
Regeneratively cooled transition duct with transversely buffered impingement nozzles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrison, Jay A; Lee, Ching-Pang; Crawford, Michael E
2015-04-21
A cooling arrangement (56) having: a duct (30) configured to receive hot gases (16) from a combustor; and a flow sleeve (50) surrounding the duct and defining a cooling plenum (52) there between, wherein the flow sleeve is configured to form impingement cooling jets (70) emanating from dimples (82) in the flow sleeve effective to predominately cool the duct in an impingement cooling zone (60), and wherein the flow sleeve defines a convection cooling zone (64) effective to cool the duct solely via a cross-flow (76), the cross-flow comprising cooling fluid (72) exhausting from the impingement cooling zone. In themore » impingement cooling zone an undimpled portion (84) of the flow sleeve tapers away from the duct as the undimpled portion nears the convection cooling zone. The flow sleeve is configured to effect a greater velocity of the cross-flow in the convection cooling zone than in the impingement cooling zone.« less
ERIC Educational Resources Information Center
Petti, Amy D.
2010-01-01
In this article, the author describes how an Oregon district redefines coaching roles to find a balance between school and district goals. As director of improvement for North Clackamas School District in Milwaukie, Oregon, near Portland, the author's role of coaching the coach was new, and the coaches welcomed the immediate feedback. Through the…
ERIC Educational Resources Information Center
Anchorage School District, AK.
This profile is the report card of the Anchorage, Alaska, School District on the academic achievement of Anchorage students. Part 1 provides a summary of performance across the entire district on a variety of important indicators of success. Part 2, published separately, profiles each of the district's schools. Part 1 contains an overview of the…
ERIC Educational Resources Information Center
Reinagel, Tyler P.
2014-01-01
School districts across the United States are often forced into situations where limited public funds must be distributed among multiple districts. These are often reliant on distribution rates negotiated by district leadership and elected officials. An example of this is Georgia's 1% Education Local Option Sales Tax (ELOST). The tax is collected…
ERIC Educational Resources Information Center
Waters, Louise Bay; Vargo, Merrill
2008-01-01
Urban district reform has been hampered by the challenge of understanding and supporting the tremendous complexity of district change. Improving this understanding through actionable, practice-based research is the purpose of this study. The authors began the study with the hypothesis that achieving districts both align their instructional systems…
ERIC Educational Resources Information Center
Miles, Karen Hawley; Odden, Allan; Fermanich, Mark; Archibald, Sarah
2005-01-01
As districts struggle to meet the demands of standards-based reform and requirements for "highly qualified" teachers in the face of increasing fiscal constraints, professional development has the potential to be a significant part of a district's improvement strategy. To use dollars effectively, districts need to think about how to best integrate…
ERIC Educational Resources Information Center
McMunn, Nancy; Schenck, Patricia; McColskey, Wendy
Whether school district support and training in standards-based assessment, grading, and reporting in classrooms can change teacher practice in these areas was studied in a Florida school district. This district, Bay District Schools of Panama City, has been working with the SERVE Regional Educational Laboratory on a project that involves teachers…
Elementary and Secondary Civil Rights Survey, 1984. District Summary Volumes 1 and 2.
ERIC Educational Resources Information Center
DBS Corp., Arlington, VA.
This 1984 survey was conducted to obtain data on the characteristics of public school students in the 50 states and the District of Columbia. The 3,510 school districts selected to participate were statistically sampled from approximately 16,000 U.S. school districts, and the schools within the selected districts were subsampled: (1) all special…
The Creative Cost Management Strategies of Two School Districts.
ERIC Educational Resources Information Center
Pheasant, Marilyn
1984-01-01
Two Oregon schools districts that have been effective in managing their resources are Reedsport, a smaller district and the subject of part 1 of this bulletin; and Beaverton, one of the largest districts in the state, the focus of part 2. The Reedsport district plans the use of its funds based on a goal-setting process in the areas of instruction,…
ERIC Educational Resources Information Center
Cooley, Dwight A.; Floyd, Koy A.
2013-01-01
Historically, the number of public school districts in the United States has decreased despite a dramatic increase in the number of students enrolled. Although public school district consolidation has impacted districts of all sizes, since the late 1930's smaller rural districts facing dwindling community resources have merged or consolidated with…
ERIC Educational Resources Information Center
National Center for Education Statistics, 2010
2010-01-01
Each district that participated in the National Assessment of Educational Progress (NAEP) 2009 Trial Urban District Assessment in reading receives a one-page snapshot report that presents key findings and trends in a condensed format. This report presents the results for Austin Independent School District's student achievement in reading. In 2009,…
ERIC Educational Resources Information Center
National Center for Education Statistics, 2010
2010-01-01
Each district that participated in the National Assessment of Educational Progress (NAEP) 2009 Trial Urban District Assessment in reading receives a one-page snapshot report that presents key findings and trends in a condensed format. This report presents the results for Austin Independent School District's student achievement in reading. In 2009,…
Reinstating district nursing: A UK perspective.
Morris, Hannah
2017-09-01
As policy directives gather pace for service provision to be delivered in primary care, district nursing has not been recognised as a valuable asset to facilitate this agenda. Investment in district nursing and specialist district nursing education has fallen. This is concurrent with an ageing district nursing workforce, a lack of recruitment and growing caseloads, as district nursing adapts to meet the challenges of the complexities of contemporary healthcare in the community. The district nurse role is complex and multifaceted and includes working collaboratively and creatively to coordinate care. Redressing the shortages of specialist district nurse practitioners with increased numbers of health care support workers will not replace the skill, knowledge, experience required to meet the complex care needs of today's society. District nursing needs to be reinstated as the valuable asset it is, through renewed investment in the service, research development and in specialist practice education. To prevent extinction district nurses need to be able to demonstrate and articulate the complexities and dynamisms of the role to reinstate themselves to their commissioners as a valuable asset for contemporary practice that can meet current health and social care needs effectively. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Comments on ionization cooling channels
Neuffer, David
2017-09-25
Ionization cooling channels with a wide variety of characteristics and cooling properties are being developed. These channels can produce cooling performances that are largely consistent with the linear ionization cooling theory developed previously. In this study, we review ionization cooling theory, discuss its application to presently developing cooling channels, and discuss criteria for optimizing cooling.
Comments on ionization cooling channels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neuffer, David
Ionization cooling channels with a wide variety of characteristics and cooling properties are being developed. These channels can produce cooling performances that are largely consistent with the linear ionization cooling theory developed previously. In this study, we review ionization cooling theory, discuss its application to presently developing cooling channels, and discuss criteria for optimizing cooling.
Kramer, Daniëlle; Droomers, Mariël; Jongeneel-Grimen, Birthe; Wingen, Marleen; Stronks, Karien; Kunst, Anton E
2014-03-11
Numerous area-based initiatives (ABIs) have been implemented in deprived neighbourhoods across Europe. These large-scale initiatives aim to tackle the socio-economic and environmental problems in these areas that might influence physical activity (PA). There is little robust evidence of their impact on PA. This study aimed to assess the impact of a Dutch ABI called the District Approach on trends in leisure-time PA in deprived districts. Repeated cross-sectional data on 48401 adults across the Netherlands were obtained from the Integrated Survey on Household Living Conditions (POLS) 2004-2011. 1517 of these adults resided in deprived target districts and 46884 adults resided elsewhere in the Netherlands. In a quasi-experimental interrupted time-series design, multilevel logistic regression analyses were performed to assess trends in leisure-time walking, cycling, and sports before and during the intervention. Trends in deprived target districts were compared with trends in various control groups. The role of the intensity of environmental interventions was also assessed. Deprived target districts showed a significantly positive change in walking trend between the pre-intervention and intervention period. The trend change in the deprived target districts was significantly larger compared to the rest of the Netherlands, but not compared to other deprived districts. For cycling and sports, neither deprived districts nor control districts showed a significant trend change. For all leisure-time PA outcomes, trend changes were not related to the intensity of environmental interventions in the deprived target districts. Some evidence was found to suggest that ABIs like the District Approach have a positive impact on leisure-time PA in deprived districts, regardless of the intensity of environmental interventions.
2014-01-01
Background Numerous area-based initiatives (ABIs) have been implemented in deprived neighbourhoods across Europe. These large-scale initiatives aim to tackle the socio-economic and environmental problems in these areas that might influence physical activity (PA). There is little robust evidence of their impact on PA. This study aimed to assess the impact of a Dutch ABI called the District Approach on trends in leisure-time PA in deprived districts. Methods Repeated cross-sectional data on 48401 adults across the Netherlands were obtained from the Integrated Survey on Household Living Conditions (POLS) 2004–2011. 1517 of these adults resided in deprived target districts and 46884 adults resided elsewhere in the Netherlands. In a quasi-experimental interrupted time-series design, multilevel logistic regression analyses were performed to assess trends in leisure-time walking, cycling, and sports before and during the intervention. Trends in deprived target districts were compared with trends in various control groups. The role of the intensity of environmental interventions was also assessed. Results Deprived target districts showed a significantly positive change in walking trend between the pre-intervention and intervention period. The trend change in the deprived target districts was significantly larger compared to the rest of the Netherlands, but not compared to other deprived districts. For cycling and sports, neither deprived districts nor control districts showed a significant trend change. For all leisure-time PA outcomes, trend changes were not related to the intensity of environmental interventions in the deprived target districts. Conclusion Some evidence was found to suggest that ABIs like the District Approach have a positive impact on leisure-time PA in deprived districts, regardless of the intensity of environmental interventions. PMID:24612770
School District Crisis Preparedness, Response, and Recovery Plans - United States, 2012.
Silverman, Brenda; Chen, Brenda; Brener, Nancy; Kruger, Judy; Krishna, Nevin; Renard, Paul; Romero-Steiner, Sandra; Avchen, Rachel Nonkin
2016-09-16
The unique characteristics of children dictate the need for school-based all-hazards response plans during natural disasters, emerging infectious diseases, and terrorism (1-3). Schools are a critical community institution serving a vulnerable population that must be accounted for in public health preparedness plans; prepared schools are adopting policies and plans for crisis preparedness, response, and recovery (2-4). The importance of having such plans in place is underscored by the development of a new Healthy People 2020 objective (PREP-5) to "increase the percentage of school districts that require schools to include specific topics in their crisis preparedness, response, and recovery plans" (5). Because decisions about such plans are usually made at the school district level, it is important to examine district-level policies and practices. Although previous reports have provided national estimates of the percentage of districts with policies and practices in place (6), these estimates have not been analyzed by U.S. Census region* and urbanicity.(†) Using data from the 2012 School Health Policies and Practices Study (SHPPS), this report examines policies and practices related to school district preparedness, response, and recovery. In general, districts in the Midwest were less likely to require schools to include specific topics in their crisis preparedness plans than districts in the Northeast and South. Urban districts tended to be more likely than nonurban districts to require specific topics in school preparedness plans. Southern districts tended to be more likely than districts in other regions to engage with partners when developing plans. No differences in district collaboration (with the exception of local fire department engagement) were observed by level of urbanicity. School-based preparedness planning needs to be coordinated with interdisciplinary community partners to achieve Healthy People 2020 PREP-5 objectives for this vulnerable population.
Texas ports and navigation districts : overview.
DOT National Transportation Integrated Search
2017-01-01
The first Navigation District was established in 1909, and there are now 24 Navigation Districts statewide.1 Navigation districts generally provide for the construction and improvement of waterways in Texas for the purpose of navigation. The creation...
2012-12-01
TROPIC CONDITIONS: EFFECTS OF THREE MICROCLIMATE COOLING CONFIGURATIONS Bruce S. Cadarette Catherine O’Brien Thermal and Mountain...Cooling HR – Heart Rate INT – Intermittent Cooling LO – Low Cooling MCCS – Microclimate Cooling System NC – No Cooling NSRDEC – Natick...develop lightweight microclimate cooling systems (MCCS) for use by dismounted Soldiers by evaluating the cooling potentials of two prototype MCCS
2010-01-01
Background The district resource allocation formula in Malawi was recently reviewed to include stunting as a proxy measure of socioeconomic status. In many countries where the concept of need has been incorporated in resource allocation, composite indicators of socioeconomic status have been used. In the Malawi case, it is important to ascertain whether there are differences between using single variable or composite indicators of socioeconomic status in allocations made to districts, holding all other factors in the resource allocation formula constant. Methods Principal components analysis was used to calculate asset indices for all districts from variables that capture living standards using data from the Malawi Multiple Indicator Cluster Survey 2006. These were normalized and used to weight district populations. District proportions of national population weighted by both the simple and composite indicators were then calculated for all districts and compared. District allocations were also calculated using the two approaches and compared. Results The two types of indicators are highly correlated, with a spearman rank correlation coefficient of 0.97 at the 1% level of significance. For 21 out of the 26 districts included in the study, proportions of national population weighted by the simple indicator are higher by an average of 0.6 percentage points. For the remaining 5 districts, district proportions of national population weighted by the composite indicator are higher by an average of 2 percentage points. Though the average percentage point differences are low and the actual allocations using both approaches highly correlated (ρ of 0.96), differences in actual allocations exceed 10% for 8 districts and have an average of 4.2% for the remaining 17. For 21 districts allocations based on the single variable indicator are higher. Conclusions Variations in district allocations made using either the simple or composite indicators of socioeconomic status are not statistically different to recommend one over the other. However, the single variable indicator is favourable for its ease of computation. PMID:20053274
[Effect of fluoride on human hypothalamus-hypophysis-testis axis hormones].
Hao, Pengfei; Ma, Xiaoying; Cheng, Xuemin; Ba, Yue; Zhu, Jingyuan; Cui, Liuxin
2010-01-01
To study of endocrine disturbing effect of fluoride on human hypothalamus-hypophysis-testis axis hormones. Sunying County, Kaifeng City was selected as polluted district which the fluoride in drinking water was 3.89 mg/L, and Shenlilou county was selected as control district which the fluoride was less than 1.0 mg/L. 150 individual lived there more than 5 years were srlected randomly. And investigated by medical examination, then blood and urine sample were collected, and the serum level of gonadotropin-releasing hormone (GnRH), luteinizing hormone (LH), testosterone (T) and estradiol (E2) were measured by RIA method, and the urine level of fluoride were measured. Other than that, the concentration of fluoride in the water, food, soil and air were detected by the standard methods. The concentrations of fluoride in the water, food and soil of the fluoride polluted district were significantly higher than those of control district (P < 0.05), and the concentration fluoride in the air of two district were not found. There was no significant difference of serum level of GnRH between fluoride polluted district and control district (P > 0.05). The serum level of LH in men of fluoride polluted district was significantly higher than that of control group (P < 0.05), and the serum level of T in men of fluoride polluted district was significantly less than that of control group (P < 0.05). There was no significant difference of serum level of LH between fluoride polluted district and control district (P > 0.05), and the serum level of T in women of fluoride polluted district was significantly higher than that of control group (P < 0.05). There was no significant difference of serum level of E2 between fluoride polluted district and control district (P > 0.05). Fluoride could effect hormone levels of each layer of the hypothalamus-hypophysis-testis axis, and show the reproductive endocrine disturbing effects. The reproductive endocrine disturbing effects of male maybe more severe than those of female.
The path dependence of district manager decision-space in Ghana
Kwamie, Aku; van Dijk, Han; Ansah, Evelyn K; Agyepong, Irene Akua
2016-01-01
The district health system in Ghana today is characterized by high resource-uncertainty and narrow decision-space. This article builds a theory-driven historical case study to describe the influence of path-dependent administrative, fiscal and political decentralization processes on development of the district health system and district manager decision-space. Methods included a non-exhaustive literature review of democratic governance in Ghana, and key informant interviews with high-level health system officials integral to the development of the district health system. Through our analysis we identified four periods of district health system progression: (1) development of the district health system (1970–85); (2) Strengthening District Health Systems Initiative (1986–93); (3) health sector reform planning and creation of the Ghana Health Service (1994–96) and (4) health sector reform implementation (1997–2007). It was observed that district manager decision-space steadily widened during periods (1) and (2), due to increases in managerial profile, and concerted efforts at managerial capacity strengthening. Periods (3) and (4) saw initial augmentation of district health system financing, further widening managerial decision-space. However, the latter half of period 4 witnessed district manager decision-space contraction. Formalization of Ghana Health Service structures influenced by self-reinforcing tendencies towards centralized decision-making, national and donor shifts in health sector financing, and changes in key policy actors all worked to the detriment of the district health system, reversing early gains from bottom-up development of the district health system. Policy feedback mechanisms have been influenced by historical and contemporary sequencing of local government and health sector decentralization. An initial act of administrative decentralization, followed by incomplete political and fiscal decentralization has ensured that the balance of power has remained at national level, with strong vertical accountabilities and dependence of the district on national level. This study demonstrates that the rhetoric of decentralization does not always mirror actual implementation, nor always result in empowered local actors. PMID:26318537
NASA Astrophysics Data System (ADS)
Miller, Christopher L.
In the United States of America, the public education system is comprised of over 14,000 school districts. Each of these unique districts is being affected by the enactment of the No Child Left Behind Act of 2001. In turn, this diverse population of school districts is determining the impact on education of this sweeping federal education policy. This study examines eight of those school districts to determine their actions related to the early phase of the implementation of one portion of NCLB, the accountability provisions prescribing standardized assessment for the determination of Adequate Yearly Progress. Specifically, this study examines what these eight Wisconsin school districts, serving from 1,000 to over 5,000 students, did with the student achievement data resulting from their state assessment, the Wisconsin Knowledge and Concepts Examinations (WKCE). A wide variety of responses were found in how school districts used the WKCE data. The eight school districts were examined to determine what features of their organizations were responsible for how they responded to the enactment of the AYP provisions, specifically how they used the WCKE data. District responses were found to be determined by district size, governance structures, personnel, and dispositions. The interactions of these characteristics were considered in light of organizational studies using conceptualizations borrowed from ecology and the theory of evolution and by studies of school districts.
Closed circuit steam cooled turbine shroud and method for steam cooling turbine shroud
Burdgick, Steven Sebastian; Sexton, Brendan Francis; Kellock, Iain Robertson
2002-01-01
A turbine shroud cooling cavity is partitioned to define a plurality of cooling chambers for sequentially receiving cooling steam and impingement cooling of the radially inner wall of the shoud. An impingement baffle is provided in each cooling chamber for receiving the cooling media from a cooling media inlet in the case of the first chamber or from the immediately upstream chamber in the case of the second through fourth chambers and includes a plurality of impingement holes for effecting the impingement cooling of the shroud inner wall.
Code of Federal Regulations, 2010 CFR
2010-01-01
... included in either the Quincy or South Irrigation Districts which lies east of township vertical line R27E... Irrigation Districts which lies west of township line R28E. (c) District No. 3—The counties of Benton...
Code of Federal Regulations, 2011 CFR
2011-01-01
... included in either the Quincy or South Irrigation Districts which lies east of township vertical line R27E... Irrigation Districts which lies west of township line R28E. (c) District No. 3—The counties of Benton...
Person-centred communication for emotional support in district nursing: SAGE and THYME model.
Griffiths, Jane
2017-12-02
Patients on district nursing caseloads have multiple physical morbidities, and related emotional concerns. District nurses are ideally placed to assess and meet patients' emotional needs but in increasingly stretched workplaces, it is difficult to find time. There is also evidence that district nurses sometimes believe they lack skills to address patients' concerns. Traditional communication skills training is useful for encouraging patients to open up about their concerns, but less helpful at finding workable solutions. District nurses can be afraid to open a 'can of worms' of concerns that they are unable to deal with. SAGE and THYME is a person-centred, evidence-based communication skills model that addresses district nurses' concerns about time and skills. It provides a structure for conversations about concerns, and empowers patients to work with district nurses to find solutions. Research suggests that it is a promising model for district nursing practice.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-19
.... District Court, Southern District of Texas, Case 7:08CR01610-001. (24) Reynol Garcia, June 12, 2009, U.S... Quilantan-Garcia, December 9, 2009, U.S. District Court, Southern District of Texas, Case 7:09CR00874-001... Texas, Case 7:09CR01019- 001. (28) Roberto Carlos Garcia-Salazar, January 31, 2009, U.S. District Court...
ERIC Educational Resources Information Center
Coyle, Shawn; Jones, Thea; Pickle, Shirley Kirk
2009-01-01
This article presents a sample of online learning programs serving very different populations: a small district spread over a vast area, a large inner school district, and a statewide program serving numerous districts. It describes how these districts successfully implemented e-learning programs in their schools and discusses the positive impact…
ERIC Educational Resources Information Center
Lee, Victor R.; Leary, Heather M.; Sellers, Linda; Recker, Mimi
2014-01-01
When introducing and implementing a new technology for science teachers within a school district, we must consider not only the end users but also the roles and influence district personnel have on the eventual appropriation of that technology. School districts are, by their nature, complex systems with multiple individuals at different levels in…
ERIC Educational Resources Information Center
National Center for Education Statistics, 2010
2010-01-01
Each district that participated in the National Assessment of Educational Progress (NAEP) 2009 Trial Urban District Assessment in reading receives a one-page snapshot report that presents key findings and trends in a condensed format. This report presents the results for San Diego Unified School District's student achievement in reading. In 2009,…
ERIC Educational Resources Information Center
National Center for Education Statistics, 2010
2010-01-01
Each district that participated in the National Assessment of Educational Progress (NAEP) 2009 Trial Urban District Assessment in reading receives a one-page snapshot report that presents key findings and trends in a condensed format. This report presents the results for San Diego Unified School District's student achievement in reading. In 2009,…
ERIC Educational Resources Information Center
Dombrowski, Richard J.
In 1983, Channahon School District 17 in Illinois was $1.3 million in debt. Real estate taxes constituted the school district's chief source of revenue, but because the state's oil industry kept its assessed valuations below the actual value of its property through the use of experts and lawyers, the school district was denied much of its income.…
ERIC Educational Resources Information Center
Adams, E. Kathleen; Vincent, Phillip E.
Data on 174 Colorado school districts were used to measure districts' responses (as indicated by per-pupil expenditures) to their own fiscal capacity and to state aid that changes over time. Colorado's modified guaranteed tax base (GTB) formula was analyzed and a model constructed that took into account the formula's limits on district spending…
ERIC Educational Resources Information Center
Al dakeel, Taghreed M.; Almannie, Mohamed A.
2015-01-01
The general school district of Riyadh is one of largest in the country of (45) school districts in Saudi Arabia. The school districts play an important roles in the development of education, therefore the objective of the study is to examine the roles of the management in the school districts to see if it is achieving competitive advantage. After…
ERIC Educational Resources Information Center
Putnam, Robert F.; Luiselli, James K.; Sennett, Kenneth; Malonson, Joanne
2002-01-01
Evaluation of out-of-district special education placement costs in the 15 largest Massachusetts public school districts found the criterion school district (which had developed a system-wide approach to behavioral intervention) had the lowest per capita cost, lowest percentage of total school budget consumed by out-of-district placements, and the…
Mujasi, Paschal N; Puig-Junoy, Jaume
2015-01-01
A key policy question for the government of Uganda is how to equitably allocate primary health care pharmaceutical budgets to districts. This paper seeks to identify variables influencing current primary health care pharmaceutical expenditure and their usefulness in allocating prospective pharmaceutical budgets to districts. This was a cross sectional, retrospective observational study using secondary administrative data. We collected data on the value of pharmaceuticals procured by primary health care facilities in each district from National Medical Stores for the financial year 2011/2012. The dependent variable was expressed as per capita district pharmaceutical expenditure. By reviewing literature we identified 26 potential explanatory variables. They include supply, need and demand, and health system organization variables that may influence the demand and supply of health services and the corresponding pharmaceutical expenditure. We collected secondary data for these variables for all the districts in Uganda (n = 112). We performed econometric analysis to estimate parameters of various regression models. There is a significant correlation between per capita district pharmaceutical expenditure and total district population, rural poverty, access to drinking water and outpatient department (OPD) per capita utilisation.(P < 0.01). The percentage of health centre IIIs (HC III) among each district's health facilities is significantly correlated with per capita pharmaceutical expenditure (P < 0.05). OPD per capita utilisation has a relatively strong correlation with per capita pharmaceutical expenditure (r = 0.498); all the other significant factors are weakly correlated with per capita pharmaceutical expenditure (r < 0.5). From several iterations of an initially developed model, the proposed final model for explaining per capita pharmaceutical expenditure explains about 53% of the variation in pharmaceutical expenditure among districts in Uganda (Adjusted R(2) = 0.528). All variables in the model are significant (p < 0.01). From evaluation of the various models, proposed variables to consider in allocating prospective primary health care pharmaceutical budgets to districts in Uganda are: district outpatient department attendance per capita, total district population, total number of government health facilities in the district and the district human poverty index.
Quantitative Data Analysis To Determine Best Food Cooling Practices in U.S. Restaurants†
Schaffner, Donald W.; Brown, Laura Green; Ripley, Danny; Reimann, Dave; Koktavy, Nicole; Blade, Henry; Nicholas, David
2017-01-01
Data collected by the Centers for Disease Control and Prevention (CDC) show that improper cooling practices contributed to more than 500 foodborne illness outbreaks associated with restaurants or delis in the United States between 1998 and 2008. CDC's Environmental Health Specialists Network (EHS-Net) personnel collected data in approximately 50 randomly selected restaurants in nine EHS-Net sites in 2009 to 2010 and measured the temperatures of cooling food at the beginning and the end of the observation period. Those beginning and ending points were used to estimate cooling rates. The most common cooling method was refrigeration, used in 48% of cooling steps. Other cooling methods included ice baths (19%), room-temperature cooling (17%), ice-wand cooling (7%), and adding ice or frozen food to the cooling food as an ingredient (2%). Sixty-five percent of cooling observations had an estimated cooling rate that was compliant with the 2009 Food and Drug Administration Food Code guideline (cooling to 41°F [5°C] in 6 h). Large cuts of meat and stews had the slowest overall estimated cooling rate, approximately equal to that specified in the Food Code guideline. Pasta and noodles were the fastest cooling foods, with a cooling time of just over 2 h. Foods not being actively monitored by food workers were more than twice as likely to cool more slowly than recommended in the Food Code guideline. Food stored at a depth greater than 7.6 cm (3 in.) was twice as likely to cool more slowly than specified in the Food Code guideline. Unventilated cooling foods were almost twice as likely to cool more slowly than specified in the Food Code guideline. Our data suggest that several best cooling practices can contribute to a proper cooling process. Inspectors unable to assess the full cooling process should consider assessing specific cooling practices as an alternative. Future research could validate our estimation method and study the effect of specific practices on the full cooling process. PMID:25836405
Restaurant Food Cooling Practices†
BROWN, LAURA GREEN; RIPLEY, DANNY; BLADE, HENRY; REIMANN, DAVE; EVERSTINE, KAREN; NICHOLAS, DAVE; EGAN, JESSICA; KOKTAVY, NICOLE; QUILLIAM, DANIELA N.
2017-01-01
Improper food cooling practices are a significant cause of foodborne illness, yet little is known about restaurant food cooling practices. This study was conducted to examine food cooling practices in restaurants. Specifically, the study assesses the frequency with which restaurants meet U.S. Food and Drug Administration (FDA) recommendations aimed at reducing pathogen proliferation during food cooling. Members of the Centers for Disease Control and Prevention’s Environmental Health Specialists Network collected data on food cooling practices in 420 restaurants. The data collected indicate that many restaurants are not meeting FDA recommendations concerning cooling. Although most restaurant kitchen managers report that they have formal cooling processes (86%) and provide training to food workers on proper cooling (91%), many managers said that they do not have tested and verified cooling processes (39%), do not monitor time or temperature during cooling processes (41%), or do not calibrate thermometers used for monitoring temperatures (15%). Indeed, 86% of managers reported cooling processes that did not incorporate all FDA-recommended components. Additionally, restaurants do not always follow recommendations concerning specific cooling methods, such as refrigerating cooling food at shallow depths, ventilating cooling food, providing open-air space around the tops and sides of cooling food containers, and refraining from stacking cooling food containers on top of each other. Data from this study could be used by food safety programs and the restaurant industry to target training and intervention efforts concerning cooling practices. These efforts should focus on the most frequent poor cooling practices, as identified by this study. PMID:23212014
Restaurant food cooling practices.
Brown, Laura Green; Ripley, Danny; Blade, Henry; Reimann, Dave; Everstine, Karen; Nicholas, Dave; Egan, Jessica; Koktavy, Nicole; Quilliam, Daniela N
2012-12-01
Improper food cooling practices are a significant cause of foodborne illness, yet little is known about restaurant food cooling practices. This study was conducted to examine food cooling practices in restaurants. Specifically, the study assesses the frequency with which restaurants meet U.S. Food and Drug Administration (FDA) recommendations aimed at reducing pathogen proliferation during food cooling. Members of the Centers for Disease Control and Prevention's Environmental Health Specialists Network collected data on food cooling practices in 420 restaurants. The data collected indicate that many restaurants are not meeting FDA recommendations concerning cooling. Although most restaurant kitchen managers report that they have formal cooling processes (86%) and provide training to food workers on proper cooling (91%), many managers said that they do not have tested and verified cooling processes (39%), do not monitor time or temperature during cooling processes (41%), or do not calibrate thermometers used for monitoring temperatures (15%). Indeed, 86% of managers reported cooling processes that did not incorporate all FDA-recommended components. Additionally, restaurants do not always follow recommendations concerning specific cooling methods, such as refrigerating cooling food at shallow depths, ventilating cooling food, providing open-air space around the tops and sides of cooling food containers, and refraining from stacking cooling food containers on top of each other. Data from this study could be used by food safety programs and the restaurant industry to target training and intervention efforts concerning cooling practices. These efforts should focus on the most frequent poor cooling practices, as identified by this study.
Accountability in district nursing practice: key concepts.
Griffith, Richard
2015-03-01
Public trust and confidence in district nurses is essential to the nurse-patient relationship that underpins effective care and treatment. That trust and confidence has even greater focus for district nurses who care for patients in their own homes. Those patients need to be able to count on the professionalism and probity of their district nurses. The professionalism and probity of district nurses is based on their accountability, which protects the public by imposing standards on district nurses and holds them answerable for their acts and omissions. This is the first of a series of articles on accountability in district nursing practice to mark the introduction of the revised Nursing and Midwifery Code on the 31 March 2015. This month's article considers the key concepts of accountability.
Body-Cooling Paradigm in Sport: Maximizing Safety and Performance During Competition.
Adams, William M; Hosokawa, Yuri; Casa, Douglas J
2016-12-01
Although body cooling has both performance and safety benefits, knowledge on optimizing cooling during specific sport competition is limited. To identify when, during sport competition, it is optimal for body cooling and to identify optimal body-cooling modalities to enhance safety and maximize sport performance. A comprehensive literature search was conducted to identify articles with specific context regarding body cooling, sport performance, and cooling modalities used during sport competition. A search of scientific peer-reviewed literature examining the effects of body cooling on exercise performance was done to examine the influence of body cooling on exercise performance. Subsequently, a literature search was done to identify effective cooling modalities that have been shown to improve exercise performance. The cooling modalities that are most effective in cooling the body during sport competition depend on the sport, timing of cooling, and feasibility based on the constraints of the sports rules and regulations. Factoring in the length of breaks (halftime substitutions, etc), the equipment worn during competition, and the cooling modalities that offer the greatest potential to cool must be considered in each individual sport. Scientific evidence supports using body cooling as a method of improving performance during sport competition. Developing a strategy to use cooling modalities that are scientifically evidence-based to improve performance while maximizing athlete's safety warrants further investigation.
ERIC Educational Resources Information Center
Leaf, Justin B.; Taubman, Mitchell; Milne, Christine; Dale, Stephanie; Leaf, Jeremy; Townley-Cochran, Donna; Tsuji, Kathleen; Kassardjian, Alyne; Alcalay, Aditt; Leaf, Ronald; McEachin, John
2016-01-01
We utilized a cool versus not cool procedure plus role-playing to teach social communication skills to three individuals diagnosed with autism spectrum disorder. The cool versus not cool procedure plus role-playing consisted of the researcher randomly demonstrating the behavior correctly (cool) two times and the behavior incorrectly (not cool) two…
The cost of the district hospital: a case study in Malawi.
Mills, A J; Kapalamula, J; Chisimbi, S
1993-01-01
Described in an analysis of the cost to the Ministry of Health of providing district health services in Malawi, with particular emphasis on the district hospital. District resource allocation patterns were assessed by carefully disaggregating district costs by level of care and hospital department. A strikingly low proportion of district recurrent costs was absorbed by salaries and wages (27-39%, depending on the district) and a surprisingly high proportion by medical supplies (24-37%). The most expensive cost centre in the hospital was the pharmacy. A total of 27-39% of total recurrent costs were spent outside the hospital and 61-73% on hospital services. The secondary care services absorbed 40-58% of district recurrent costs. Unit costs by hospital department varied considerably by district, with one hospital being consistently the most expensive and another the cheapest. A total of 3-10 new outpatients could be treated for the average cost of 1 inpatient-day, while 34-55 could be treated for the average cost of 1 inpatient. The efficiency of hospital operations, the scope for redistributing resources districtwide, and the costing methodology are discussed.
The cost of the district hospital: a case study in Malawi.
Mills, A. J.; Kapalamula, J.; Chisimbi, S.
1993-01-01
Described in an analysis of the cost to the Ministry of Health of providing district health services in Malawi, with particular emphasis on the district hospital. District resource allocation patterns were assessed by carefully disaggregating district costs by level of care and hospital department. A strikingly low proportion of district recurrent costs was absorbed by salaries and wages (27-39%, depending on the district) and a surprisingly high proportion by medical supplies (24-37%). The most expensive cost centre in the hospital was the pharmacy. A total of 27-39% of total recurrent costs were spent outside the hospital and 61-73% on hospital services. The secondary care services absorbed 40-58% of district recurrent costs. Unit costs by hospital department varied considerably by district, with one hospital being consistently the most expensive and another the cheapest. A total of 3-10 new outpatients could be treated for the average cost of 1 inpatient-day, while 34-55 could be treated for the average cost of 1 inpatient. The efficiency of hospital operations, the scope for redistributing resources districtwide, and the costing methodology are discussed. PMID:8324852
Bongers, Coen C. W. G.; Hopman, Maria T. E.; Eijsvogels, Thijs M. H.
2017-01-01
ABSTRACT Exercise-induced increases in core body temperature could negative impact performance and may lead to development of heat-related illnesses. The use of cooling techniques prior (pre-cooling), during (per-cooling) or directly after (post-cooling) exercise may limit the increase in core body temperature and therefore improve exercise performance. The aim of the present review is to provide a comprehensive overview of current scientific knowledge in the field of pre-cooling, per-cooling and post-cooling. Based on existing studies, we will discuss 1) the effectiveness of cooling interventions, 2) the underlying physiological mechanisms and 3) practical considerations regarding the use of different cooling techniques. Furthermore, we tried to identify the optimal cooling technique and compared whether cooling-induced performance benefits are different between cool, moderate and hot ambient conditions. This article provides researchers, physicians, athletes and coaches with important information regarding the implementation of cooling techniques to maintain exercise performance and to successfully compete in thermally stressful conditions. PMID:28349095
Cooling arrangement for a tapered turbine blade
Liang, George
2010-07-27
A cooling arrangement (11) for a highly tapered gas turbine blade (10). The cooling arrangement (11) includes a pair of parallel triple-pass serpentine cooling circuits (80,82) formed in an inner radial portion (50) of the blade, and a respective pair of single radial channel cooling circuits (84,86) formed in an outer radial portion (52) of the blade (10), with each single radial channel receiving the cooling fluid discharged from a respective one of the triple-pass serpentine cooling circuit. The cooling arrangement advantageously provides a higher degree of cooling to the most highly stressed radially inner portion of the blade, while providing a lower degree of cooling to the less highly stressed radially outer portion of the blade. The cooling arrangement can be implemented with known casting techniques, thereby facilitating its use on highly tapered, highly twisted Row 4 industrial gas turbine blades that could not be cooled with prior art cooling arrangements.
Cultivating Labor Management Collaboration
ERIC Educational Resources Information Center
Spector, Stacy
2013-01-01
In many districts, the notion of labor groups and district administration working together conjures descriptions of war and battle rather than cooperation and collaboration. However, in San Juan Unified School District, the headline, "Union and District Exhibit Positive Partnership" exemplifies the changing relationship between teacher…
77 FR 69707 - Additional Designations, Foreign Narcotics Kingpin Designation Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-20
..., Hazarjuft Area, Garmsir District, Helmand Province, Afghanistan; alt. POB Laki Village, Garmsir District, Helmand Province, Afghanistan; alt. POB Lakari Village, Garmsir District, Helmand Province, Afghanistan; alt. POB Darvishan, Garmsir District, Helmand Province, Afghanistan; alt. POB De Luy Wiyalah Village...
Code of Federal Regulations, 2010 CFR
2010-01-01
...; (2) changes in the relative position of existing districts with respect to onion production; (3) the... and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE ONIONS GROWN IN CERTAIN DESIGNATED... Districts. (a) For the purpose of selecting committee members, the following districts of the production...
ERIC Educational Resources Information Center
Levin, Jesse; Manship, Karen; Chambers, Jay; Johnson, Jerry; Blankenship, Charles
2011-01-01
This report presents the first detailed comparison of resource allocation between rural and nonrural districts in the West Region. Three regional characteristics often associated with rural districts were chosen for the analysis: district enrollment, student population density within a district (students per square mile), and drive time from the…
ERIC Educational Resources Information Center
Stuart, Lindsey; Hahnel, Carrie
2011-01-01
In this report, The Education Trust-West grades the 146 largest unified school districts in California on four key indicators of student performance to see how well they are serving their African-American, Latino, and low-income students. While most districts in California earn Cs and Ds on these indicators, some districts prove that more is…
Analysis and comparison of wall cooling schemes for advanced gas turbine applications
NASA Technical Reports Server (NTRS)
Colladay, R. S.
1972-01-01
The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.
Katkar, Dhananjay; Mote, Balu Natha; Adhav, Ambadas; Muthuvel, Thirumugam; Kadam, Suhas
2017-01-01
Leprosy or Hansen's disease, a chronic infectious disease caused by Mycobacterium leprae is a serious public health concern because of associated case load, morbidity and stigma attached to it. India achieved elimination of leprosy as a public health problem (prevalence rate [PR]<1 case/10,000 population) at the national level on January 1, 2006, still 19% districts in the country report PR more than one. In Maharashtra, it is found that very few districts within the state or very few pockets within the district are actually having leprosy burden. (1) Identification of region-wise actual "hot-spot" districts/pockets within state of Maharashtra.(2) Further drop-down below the district and block to tribal belt for understanding the actual high risk area/belt within the tribal districts. Secondary data analysis of leprosy patients registered in the State during the period 2008-2015. PR per 10,000 was found more in Vidharbha region followed by rest of Maharashtra and then Marathwada. Analysis showed that, there are tribal districts and tribal area within tribal districts which are having higher leprosy burden as compared to the all other districts indicating need of allocation of programme funds and facilities to these tribal belts for the effective control and elimination of leprosy. National Leprosy Eradication Programme should focus on tribal belt for effective control. Without giving extra attention to these tribal areas within high risk district/pockets efforts of eradication of leprosy by 2018 would be unrealistic and impractical.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Dafen; Jiang, Jiuchun; Kim, Gi-Heon
Choosing a proper cooling method for a lithium-ion (Li-ion) battery pack for electric drive vehicles (EDVs) and making an optimal cooling control strategy to keep the temperature at a optimal range of 15 degrees C to 35 degrees C is essential to increasing safety, extending the pack service life, and reducing costs. When choosing a cooling method and developing strategies, trade-offs need to be made among many facets such as costs, complexity, weight, cooling effects, temperature uniformity, and parasitic power. This paper considers four cell-cooling methods: air cooling, direct liquid cooling, indirect liquid cooling, and fin cooling. To evaluate theirmore » effectiveness, these methods are assessed using a typical large capacity Li-ion pouch cell designed for EDVs from the perspective of coolant parasitic power consumption, maximum temperature rise, temperature difference in a cell, and additional weight used for the cooling system. We use a state-of-the-art Li-ion battery electro-chemical thermal model. The results show that under our assumption an air-cooling system needs 2 to 3 more energy than other methods to keep the same average temperature; an indirect liquid cooling system has the lowest maximum temperature rise; and a fin cooling system adds about 40% extra weight of cell, which weighs most, when the four kinds cooling methods have the same volume. Indirect liquid cooling is a more practical form than direct liquid cooling though it has slightly lower cooling performance.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
... the California State Implementation Plan, Sacramento Metropolitan Air Quality Management District... Metropolitan Air Quality Management District (SMAQMD or District) portion of the California State... Designee. (i) Incorporation by Reference. (A) Sacramento Metropolitan Air Quality Management District. (1...
76 FR 31935 - District Export Council Nomination Opportunity
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-02
... DEPARTMENT OF COMMERCE International Trade Administration District Export Council Nomination... of opportunity for appointment to serve as a District Export Council member. SUMMARY: The Department... Secretary of Commerce to serve as members of one of the 60 District Export Councils (DECs) nationwide. DECs...
ERIC Educational Resources Information Center
Whitaker, Kathryn
2006-01-01
Nationwide, school district administrators are puzzling about how to increase the number of high quality principal candidates. Some districts have started programs to grow their own administrators. These districts, sometimes in conjunction with university programs, are providing training and mentoring for future school leaders. Some districts are…
Preparing Documents Recorder Terms District Info District Contact Info Find Your District RO District Map FAQs Closures/Notices Contact Us State of Alaska / Natural Resources / Recorder's Office Recording imply an endorsement of that organization, site, product, or service. Simplifile contact information
Sexual Harassment Policies in Florida School Districts.
ERIC Educational Resources Information Center
Rienzo, Barbara A.; Moore, Michele Johnson
1998-01-01
Investigated the extent to which Florida's school districts complied with the Florida Department of Education's (FDOE) recommendations for addressing sexual harassment in schools. Surveys of district equity coordinators and analysis of policies indicated that most districts approved sexual harassment policies incorporating many FDOE…
Continuously pumping and reactivating gas pump
Batzer, T.H.; Call, W.R.
Apparatus for continuous pumping using cycling cryopumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels that alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independant pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.
Continuously pumping and reactivating gas pump
Batzer, Thomas H.; Call, Wayne R.
1984-01-01
Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.
Decentralization in Zambia: resource allocation and district performance.
Bossert, Thomas; Chitah, Mukosha Bona; Bowser, Diana
2003-12-01
Zambia implemented an ambitious process of health sector decentralization in the mid 1990s. This article presents an assessment of the degree of decentralization, called 'decision space', that was allowed to districts in Zambia, and an analysis of data on districts available at the national level to assess allocation choices made by local authorities and some indicators of the performance of the health systems under decentralization. The Zambian officials in health districts had a moderate range of choice over expenditures, user fees, contracting, targeting and governance. Their choices were quite limited over salaries and allowances and they did not have control over additional major sources of revenue, like local taxes. The study found that the formula for allocation of government funding which was based on population size and hospital beds resulted in relatively equal per capita expenditures among districts. Decentralization allowed the districts to make decisions on internal allocation of resources and on user fee levels and expenditures. General guidelines for the allocation of resources established a maximum and minimum percentage to be allocated to district offices, hospitals, health centres and communities. Districts tended to exceed the maximum for district offices, but the large urban districts and those without public district hospitals were not even reaching the minimum for hospital allocations. Wealthier and urban districts were more successful in raising revenue through user fees, although the proportion of total expenditures that came from user fees was low. An analysis of available indicators of performance, such as the utilization of health services, immunization coverage and family planning activities, found little variation during the period 1995-98 except for a decline in immunization coverage, which may have also been affected by changes in donor funding. These findings suggest that decentralization may not have had either a positive or negative impact on services.
Regional health accounts for Pakistan--expenditure disparities on provincial and district level.
Lorenz, Christian; Khalid, Muhammad
2011-05-01
Since May 2009 the first National Health Accounts (NHA) for Pakistan have been finalised and published by Federal Bureau of Statistics (FBS) in cooperation with German Technical Cooperation (GTZ). This paper goes one step ahead of the report and analyses in more detail the regional differences in health expenditure structures in Pakistan. The further analyses can be divided into four parts: health expenditures in provinces (Provincial Health Accounts, PHA), Punjab provincial and district governments health expenditures and its comparison with ADB figures, all districts of Pakistan and comparison between total district government and provincial government expenditure for each province; the latter calculation is applied as indication for the degree of fiscal autonomy of the districts in each province. Consequently, first the provincial health expenditures by Financial Agents is analysed and compared between the provinces which leads to very heterogeneous results (section 2); the per capita health expenditures differ from 16 to 23 USD. Secondly, NHA results on Punjab district government are compared with available ADB results and differences in methods as possible reasons for different results are presented (section 3). Third, district data of all district governments in all four Pakistani provinces are analysed on the level of detailed function codes in section 4; the aim is to discover regional differences between districts of the same as well as of different provinces. Fourth, in section 5 the degree of fiscal autonomy on health of the districts in each province is analysed; therefore the ordinance description is reviewed and total district government with total provincial government expenditures are compared per province. Finally recommendations for future rounds of NHA in Pakistan are given regarding formats and necessities of detailed health expenditure data collection to ensure evidence based decision making not only on federal, but also on provincial and district level.
Cooling circuit for steam and air-cooled turbine nozzle stage
Itzel, Gary Michael; Yu, Yufeng
2002-01-01
The turbine vane segment includes inner and outer walls with a vane extending therebetween. The vane includes leading and trailing edge cavities and intermediate cavities. An impingement plate is spaced from the outer wall to impingement-cool the outer wall. Post-impingement cooling air flows through holes in the outer wall to form a thin air-cooling film along the outer wall. Cooling air is supplied an insert sleeve with openings in the leading edge cavity for impingement-cooling the leading edge. Holes through the leading edge afford thin-film cooling about the leading edge. Cooling air is provided the trailing edge cavity and passes through holes in the side walls of the vane for thin-film cooling of the trailing edge. Steam flows through a pair of intermediate cavities for impingement-cooling of the side walls. Post-impingement steam flows to the inner wall for impingement-cooling of the inner wall and returns the post-impingement cooling steam through inserts in other intermediate cavities for impingement-cooling the side walls of the vane.
1993-1994 Final technical report for establishing the SECME Model in the District of Columbia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vickers, R.G.
1995-12-31
This is the final report for a program to establish the SECME Model in the District of Columbia. This program has seen the development of a partnership between the District of Columbia Public Schools, the University of the District of Columbia, the Department of Energy, and SECME. This partnership has demonstrated positive achievement in mathematics and science education and learning in students within the District of Columbia.
,
1990-01-01
This is a polygon coverage of 104th Congressional District boundaries obtained from the U.S. Bureau of the Census. The 103rd Congress was the first Congress that reflected the reapportionment and delineation of congressional districts based on the 1990 census. The next (104th) Congress reflects redelineation of districts that occurred for six states: Georgia, Louisiana, Maine, Minnesota, South Carolina, and Virginia. Congressional Districts U.S. House of Representatives Census TIGER/Line Files
Smith, Gregory C.; Tokarz, Richard D.; Parry, Jr., Harvey L.; Braun, Daniel J.
1980-01-01
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water.
Olson, Jerry C.
1988-01-01
The Cochetopa and Marshall Pass uranium districts are in Saguache and Gunnison Counties, south-central Colorado. Geologic mapping of both districts has shown that their structural history and geologic relationships have a bearing on the distribution and origin of their uranium deposits. In both districts, the principal uranium deposits are situated at the intersection of major faults with Tertiary erosion surfaces. These surfaces were buried by early Tertiary siliceous tuffs-- a likely source of the uranium. That uranium deposits are related to such unconformities in various parts of the world has been suggested by many other authors. The purpose of this study is to understand the geology of the two districts and to define a genetic model for uranium deposits that may be useful in the discovery and evaluation of uranium deposits in these and other similar geologic settings. The Cochetopa and Marshall Pass uranium districts produced nearly 1,200 metric tons of uranium oxide from 1956 to 1963. Several workings at the Los Ochos mine in the Cochetopa district, and the Pitch mine in the Marshall Pass district, accounted for about 97 percent of this production, but numerous other occurrences of uranium are known in the two districts. As a result of exploration of the Pitch deposit in the 1970's, a large open-pit mining operation began in 1978. Proterozoic rocks in both districts comprise metavolcanic, metasedimentary, and igneous units. Granitic rocks, predominantly quartz monzonitic in composition, occupy large areas. In the northwestern part of the Cochetopa district, metavolcanic and related metasedimentary rocks are of low grade (lower amphibolite facies). In the Marshall Pass district, layered metamorphic rocks are predominantly metasedimentary and are of higher (sillimanite subfacies) grade than the Cochetopa rocks. Paleozoic sedimentary rocks in the Marshall Pass district range from Late Cambrian to Pennsylvanian in age and are 700 m thick. The Paleozoic rocks include, from oldest to youngest, the Sawatch Quartzite, Manitou Dolomite, Harding Quartzite, Fremont Dolomite, Parting Formation and Dyer Dolomite of the Chaffee Group, Leadville Dolomite, and Belden Formation. In the Cochetopa district, Paleozoic rocks are absent. Mesozoic sedimentary rocks overlie the Precambrian rocks in the Cochetopa district and comprise the Junction Creek Sandstone, Morrison Formation, Dakota Sandstone, and Mancos Shale. In the Marshall Pass district, Mesozoic rocks are absent and were presumably removed by pre-Tertiary erosion. Tertiary volcanic rocks were deposited on an irregular surface of unconformity; they blanketed both districts but have been eroded, away from much of the area. They include silicic ash flows as well as andesitic lava flows and breccias. In the Marshall Pass district, a 20to 20D-m thickness of waterlaid tuff of early Tertiary age indicates the former presence of a lake over much of the district. In the Cochetopa district, faults have a predominantly east-west trend, and the major Los Ochos fault shows displacement during Laramide time. In the Marshall Pass district, the Chester fault is a major north-trending reverse fault along which Proterozoic rocks have been thrust westward over Paleozoic and Proterozoic rocks. Displacement on the Chester fault was almost entirely of Laramide age. Both faults and old erosion surfaces or unconformities are important in the origin of uranium deposits because of their influence on the movement and localization of ore-forming solutions. In the Cochetopa district, all the known uranium occurrences crop out within 100 m of the inferred position of the unconformity surface beneath the Tertiary volcanic rocks. Much of the district was part of the drainage of an ancestral Cochetopa Creek. The principal uranium deposit, at the Los Ochos mine, is localized along the Los Ochos fault and is near the bottom of the paleovalley where the paleovalley crosses the fault. This
Cooling of trapped ions by resonant charge exchange
NASA Astrophysics Data System (ADS)
Dutta, Sourav; Rangwala, S. A.
2018-04-01
The two most widely used ion cooling methods are laser cooling and sympathetic cooling by elastic collisions (ECs). Here, we demonstrate another method of cooling ions that is based on resonant charge exchange (RCE) between the trapped ion and the ultracold parent atom. Specifically, trapped C s+ ions are cooled by collisions with cotrapped, ultracold Cs atoms and, separately, by collisions with cotrapped, ultracold Rb atoms. We observe that the cooling of C s+ ions by Cs atoms is more efficient than the cooling of C s+ ions by Rb atoms. This signals the presence of a cooling mechanism apart from the elastic ion-atom collision channel for the Cs-C s+ case, which is cooling by RCE. The efficiency of cooling by RCE is experimentally determined and the per-collision cooling is found to be two orders of magnitude higher than cooling by EC. The result provides the experimental basis for future studies on charge transport by electron hopping in atom-ion hybrid systems.
Valadez, Joseph J; Devkota, Baburam; Pradhan, Madan Mohan; Meherda, Pramod; Sonal, G S; Dhariwal, Akshay; Davis, Rosemary
2014-10-01
This paper reports the first trial of Lot Quality Assurance Sampling (LQAS) assessing associations between access to LQAS data and subsequent improvements in district programming. This trial concerns India's approach to addressing an increase in malaria-attributable deaths by training community health workers to diagnose, treat and prevent malaria, while using LQAS to monitor sub-district performance and make programme improvements. The Ministry of Health introduced LQAS into four matched high malaria burden districts (Annual Parasite Incidence >5) (N > 5 million). In each sub-district, we sampled four populations in three 6-monthly surveys: households, children <5 years, people with fever in the last 2 weeks and community health workers. In three districts, trained local staff collected, analysed and used data for programme management; in one control district, non-local staff collected data and did not disseminate results. For eight indicators, we calculated the change in proportion from survey one to three and used a Difference-in-Differences test to compare the relative change between intervention and control districts. Coverage increased from survey one to three for 24 of 32 comparisons. Difference-in-Differences tests revealed that intervention districts exhibited significantly greater change in four of six vertical strategies (insecticide treated bed-nets and indoor residual spraying), one of six treatment-seeking behaviours and four of 12 health worker capacity indicators. The control district displayed greater improvement than two intervention districts for one health worker capacity indicator. One district with poor management did not improve. In this study, LQAS results appeared to support district managers to increase coverage in underperforming areas, especially for vertical strategies in the presence of diligent managers. © 2014 The Authors. Tropical Medicine & International Health published by John Wiley & Sons Ltd.
Grime, L P; Horsley, S D
1995-12-01
The aims of the study were to examine whether Health Districts in the North Western Region complied with the recommendations in the Abrams report regarding the control of communicable disease [incorporated into the Annex to Circular HSG(93)56], and to identify areas that need further attention. The recommendations were extracted and arranged in questionnaire form. Further items were included dealing with the use of Epinet in communicating with the profession. A compliance score was derived from affirmative and qualified affirmative responses. Many recommendations were met by all or most Districts. Compliance was 90 percent or over for 58 percent of the questions where an assessment was appropriate. Of the 16 Districts in consortia, 75 percent did not have a consortium plan. Day-to-day plans were informal in 21 percent of Districts. In 63 percent of Districts the Family Health Services Authority (FHSA) was not involved to the extent that it should be. The Consultant in Communicable Disease Control (CCDC) had insufficient District Health Authority support in 42 percent of Districts and insufficient Local Authority support in 16 percent of Districts. In 58 percent of Districts there was lack of inclusion of matters relating to the control of infectious disease in contractual statements between purchaser and provider. There was a lack of audit in 47 percent of Districts. One plan or a compatible series of plans are required across each District. Informal day-to-day plans should be formalized. The FHSA should be fully involved in infectious disease control plans. Certain Districts require a Community Infection Control Nurse, accountable to the CCDC and/or administrative support to input and scan surveillance data. Contractual statements between purchaser and provider should include appropriate infection control requirements when this is not already the case. Communicable disease control audit should be a regular part of CCDC duties.
7 CFR 982.31 - Grower districts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 8 2010-01-01 2010-01-01 false Grower districts. 982.31 Section 982.31 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... importance of production in each district and the number of growers in each district; (2) the geographic...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-26
... the California State Implementation Plan, Northern Sierra Air Quality Management District, Sacramento Metropolitan Air Quality Management District, and South Coast Air Quality Management District AGENCY... the Northern Sierra Air Quality Management District (NSAQMD), Sacramento Metropolitan Air Quality...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... the California State Implementation Plan, Butte County Air Quality Management District and Sacramento Metropolitan Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION: Direct... Quality Management District (BCAQMD) and Sacramento Metropolitan Air Quality Management District (SMAQMD...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-14
... the California State Implementation Plan, Sacramento Metropolitan Air Quality Management District and South Coast Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION... Metropolitan Air Quality Management District (SMAQMD) and South Coast Air Quality Management District (SCAQMD...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-29
... Quality Implementation Plan; California; Sacramento Metropolitan Air Quality Management District... to the Sacramento Metropolitan Air Quality Management District (SMAQMD or District) portion of the..., Sacramento Metropolitan Air Quality Management District, Rule 214 (Federal New Source Review), Rule 203...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-26
... California State Implementation Plan, Northern Sierra Air Quality Management District, Sacramento Metropolitan Air Quality Management District, and South Coast Air Quality Management District AGENCY... approve revisions to the Northern Sierra Air Quality Management District (NSAQMD), Sacramento Metropolitan...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-14
... the California State Implementation Plan, Sacramento Metropolitan Air Quality Management District and South Coast Air Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION... Management District (SMAQMD) and South Coast Air Quality Management District (SCAQMD) portions of the...
7 CFR 1210.401 - District conventions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false District conventions. 1210.401 Section 1210.401 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... multi-State districts, no one State shall have nominees for more than three of the four district...
78 FR 32622 - District Export Council Nomination Opportunity
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-31
... Administration District Export Council Nomination Opportunity AGENCY: International Trade Administration, Department of Commerce. ACTION: Notice of Opportunity for Appointment to serve as a District Export Council... consideration for appointment by the Secretary of Commerce to serve as members of one of the 59 District Export...
Spatial Dependency and Contextual Effects on Academic Achievement
ERIC Educational Resources Information Center
Matlock, Ki; Song, Joon Jin; Goering, Christian Z.
2014-01-01
This study investigated the influences of district-related variables on a district's academic performance. Arkansas augmented benchmark examination scores were used to measure a district's scholastic achievement. Spatial analysis fit each district's performance to its geographical location; spatial autocorrelation measured the amount of influence…
District Learning Tied to Student Learning
ERIC Educational Resources Information Center
McFadden, Ledyard
2009-01-01
Winners and finalists for the annual Broad Prize for Urban Education have consistently outperformed peer districts serving similar student populations. What makes the difference? These districts consistently demonstrate a learning loop that influences the district's ability to learn, which ultimately influences student opportunities to learn.…
Code of Federal Regulations, 2010 CFR
2010-01-01
... out a local soil and water conservation program. Such district or unit of government may be referred to as a “conservation district,” “soil conservation district,” “soil and water conservation district... name. Conservation practice means one or more conservation improvements and activities, including...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-06
... the California State Implementation Plan, Imperial County Air Pollution Control District, Kern County Air Pollution Control District, and Ventura County Air Pollution Control District AGENCY... the Imperial County Air Pollution Control District (ICAPCD), Kern County Air Pollution Control...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-31
... the California State Implementation Plan, Santa Barbara Air Pollution Control District, Antelope Valley Air Quality Management District, Ventura County Air Pollution Control District and Placer County Air Pollution Control District AGENCY: Environmental Protection Agency (EPA). ACTION: Direct final...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-31
... the California State Implementation Plan, Santa Barbara Air Pollution Control District, Placer County Air Pollution Control District, Antelope Valley Air Quality Management District, and Ventura County Air Pollution Control District AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule...
Code of Federal Regulations, 2012 CFR
2012-01-01
... to the State or territorial soil conservation district law, or tribal law. The subdivision may be a conservation district, soil conservation district, soil and water conservation district, resource conservation... county or area, in accordance with Sec. 8(b) of the Soil Conservation and Domestic Allotment Act, as...
Code of Federal Regulations, 2014 CFR
2014-01-01
... to the State or territorial soil conservation district law, or tribal law. The subdivision may be a conservation district, soil conservation district, soil and water conservation district, resource conservation... county or area, in accordance with Sec. 8(b) of the Soil Conservation and Domestic Allotment Act, as...
Code of Federal Regulations, 2013 CFR
2013-01-01
... to the State or territorial soil conservation district law, or tribal law. The subdivision may be a conservation district, soil conservation district, soil and water conservation district, resource conservation... county or area, in accordance with Sec. 8(b) of the Soil Conservation and Domestic Allotment Act, as...
26 CFR 301.7701-10 - District director.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 18 2010-04-01 2010-04-01 false District director. 301.7701-10 Section 301.7701-10 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Definitions § 301.7701-10 District director. The term district...
ERIC Educational Resources Information Center
LaFee, Scott
2002-01-01
Describes the use of data-driven decision-making in four school districts: Plainfield Public Schools, Plainfield, New Jersey; Palo Alto Unified School District, Palo Alto, California; Francis Howell School District in eastern Missouri, northwest of St. Louis; and Rio Rancho Public Schools, near Albuquerque, New Mexico. Includes interviews with the…
Drought disaster vulnerability mapping of agricultural sector in Bringin District, Semarang Regency
NASA Astrophysics Data System (ADS)
Lestari, D. R.; Pigawati, B.
2018-02-01
Agriculture sector is a sector that is directly affected by drought. The phenomenon of drought disaster on agriculture sector has occurred in Semarang regency. One of districts in Semarang which is affected by drought is Bringin district. Bringin district is a productive agricultural area. However, the district experienced the most severe drought in 2015. The question research of this study is, “How is the spatial distribution of drought vulnerability on agriculture sector in Bringin district, Semarang regency?” The purpose of this study is to determine the spatial distribution of drought vulnerability on agriculture sector to village units in Bringin district. This study investigated drought vulnerability based on Intergovernmental Panel on Climate Change (IPCC) by analyzing exposure, sensitivity, and adaptive capacity through mapping process. This study used quantitative approach. There were formulation analysis, scoring analysis, and overlay analysis. Drought vulnerability on agriculture sector in Bringin district was divided into three categories: low, medium, and high.
Turbine airfoil with laterally extending snubber having internal cooling system
Scribner, Carmen Andrew; Messmann, Stephen John; Marsh, Jan H.
2016-09-06
A turbine airfoil usable in a turbine engine and having at least one snubber with a snubber cooling system positioned therein and in communication with an airfoil cooling system is disclosed. The snubber may extend from the outer housing of the airfoil toward an adjacent turbine airfoil positioned within a row of airfoils. The snubber cooling system may include an inner cooling channel separated from an outer cooling channel by an inner wall. The inner wall may include a plurality of impingement cooling orifices that direct impingement fluid against an outer wall defining the outer cooling channel. In one embodiment, the cooling fluids may be exhausted from the snubber, and in another embodiment, the cooling fluids may be returned to the airfoil cooling system. Flow guides may be positioned in the outer cooling channel, which may reduce cross-flow by the impingement orifices, thereby increasing effectiveness.
Microtextured Surfaces for Turbine Blade Impingement Cooling
NASA Technical Reports Server (NTRS)
Fryer, Jack
2014-01-01
Gas turbine engine technology is constantly challenged to operate at higher combustor outlet temperatures. In a modern gas turbine engine, these temperatures can exceed the blade and disk material limits by 600 F or more, necessitating both internal and film cooling schemes in addition to the use of thermal barrier coatings. Internal convective cooling is inadequate in many blade locations, and both internal and film cooling approaches can lead to significant performance penalties in the engine. Micro Cooling Concepts, Inc., has developed a turbine blade cooling concept that provides enhanced internal impingement cooling effectiveness via the use of microstructured impingement surfaces. These surfaces significantly increase the cooling capability of the impinging flow, as compared to a conventional untextured surface. This approach can be combined with microchannel cooling and external film cooling to tailor the cooling capability per the external heating profile. The cooling system then can be optimized to minimize impact on engine performance.
Turbine inter-disk cavity cooling air compressor
Little, David Allen
2001-01-01
A combustion turbine may have a cooling circuit for directing a cooling medium through the combustion turbine to cool various components of the combustion turbine. This cooling circuit may include a compressor, a combustor shell and a component of the combustion turbine to be cooled. This component may be a rotating blade of the combustion turbine. A pressure changing mechanism is disposed in the combustion turbine between the component to be cooled and the combustor shell. The cooling medium preferably flows from the compressor to the combustor shell, through a cooler, the component to the cooled and the pressure changing mechanism. After flowing through the pressure changing mechanism, the cooling medium is returned to the combustor shell. The pressure changing mechanism preferably changes the pressure of the cooling medium from a pressure at which it is exhausted from the component to be cooled to approximately that of the combustor shell.
2012-01-01
Background Theileriosis, caused by Theileria parva, is an economically important disease in Africa. It is a major constraint to the development of the livestock industry in some parts of eastern, central and southern Africa. In Zambia, theileriosis causes losses of up to 10,000 cattle annually. Methods Cattle blood samples were collected for genetic analysis of Theileria parva from Isoka and Petauke districts in Zambia. Microsatellite analysis was then performed on all Theileria parva positive samples for PCR using a panel of 9 microsatellite markers. Microsatellite data was analyzed using microsatellite toolkit, GenAlEx ver. 6, Fstat ver. 2.9.3.2, and LIAN computer softwares. Results The combined percentage of positive samples in both districts determined by PCR using the p104 gene primers was 54.9% (95% CI: 46.7 – 63.1%, 78/142), while in each district, it was 44.8% (95% CI: 34.8 – 54.8%) and 76.1% (95% CI = 63.9 – 88.4%) for Isoka and Petauke districts, respectively. We analyzed the population genetic structure of Theileria parva from a total of 61 samples (33 from Isoka and 28 from Petauke) using a panel of 9 microsatellite markers encompassing the 4 chromosomes of Theileria parva. Wright’s F index (FST = 0.178) showed significant differentiation between the Isoka and Petauke populations. Linkage disequilibrium was observed when populations from both districts were treated as a single population. When analyzed separately, linkage disequilibrium was observed in Kanyelele and Kalembe areas in Isoka district, Isoka district overall and in Petauke district. Petauke district had a higher multiplicity of infection than Isoka district. Conclusion Population genetic analyses of Theileria parva from Isoka and Petauke districts showed a low level of genotype exchange between the districts, but a high level of genetic diversity within each district population, implying genetic and geographic sub-structuring between the districts. The sub-structuring observed, along with the lack of panmixia in the populations, could have been due to low transmission levels at the time of sampling. However, the Isoka population was less diverse than the Petauke population. PMID:23146577
The path dependence of district manager decision-space in Ghana.
Kwamie, Aku; van Dijk, Han; Ansah, Evelyn K; Agyepong, Irene Akua
2016-04-01
The district health system in Ghana today is characterized by high resource-uncertainty and narrow decision-space. This article builds a theory-driven historical case study to describe the influence of path-dependent administrative, fiscal and political decentralization processes on development of the district health system and district manager decision-space. Methods included a non-exhaustive literature review of democratic governance in Ghana, and key informant interviews with high-level health system officials integral to the development of the district health system. Through our analysis we identified four periods of district health system progression: (1) development of the district health system (1970-85); (2) Strengthening District Health Systems Initiative (1986-93); (3) health sector reform planning and creation of the Ghana Health Service (1994-96) and (4) health sector reform implementation (1997-2007). It was observed that district manager decision-space steadily widened during periods (1) and (2), due to increases in managerial profile, and concerted efforts at managerial capacity strengthening. Periods (3) and (4) saw initial augmentation of district health system financing, further widening managerial decision-space. However, the latter half of period 4 witnessed district manager decision-space contraction. Formalization of Ghana Health Service structures influenced by self-reinforcing tendencies towards centralized decision-making, national and donor shifts in health sector financing, and changes in key policy actors all worked to the detriment of the district health system, reversing early gains from bottom-up development of the district health system. Policy feedback mechanisms have been influenced by historical and contemporary sequencing of local government and health sector decentralization. An initial act of administrative decentralization, followed by incomplete political and fiscal decentralization has ensured that the balance of power has remained at national level, with strong vertical accountabilities and dependence of the district on national level. This study demonstrates that the rhetoric of decentralization does not always mirror actual implementation, nor always result in empowered local actors. © The Author 2015. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
Guidelines for preparing a quality assurance plan for district offices of the U.S. Geological Survey
Schroder, L.J.; Shampine, W.J.
1992-01-01
The U.S. Geological Survey has a policy that requires each District office to prepare a Quality Assurance Plan. This plan is a combination of a District's management principles and quality assurance processes. The guidelines presented in this report provide a framework or expanded outline that a District can use to prepare a plan. Parti- cular emphasis is given to a District's: (1) quality assurance policies; (2) organization and staff responsibilities; and (3) program and project planning. The guidelines address the 'how', 'what', and 'who' questions that need to be answered when a District Quality Assurance Plan is prepared.
Liquid metal cooled nuclear reactors with passive cooling system
Hunsbedt, Anstein; Fanning, Alan W.
1991-01-01
A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of cooling medium flow circuits which cooperate to remove and carry heat away from the fuel core upon loss of the normal cooling flow circuit to areas external thereto.
State of the District Address, 1982.
ERIC Educational Resources Information Center
Koltai, Leslie
This address by the Chancellor of the Los Angeles Community College District (LACCD) discusses recent and long-term changes in the district's programs, educational quality, and financial standing, and suggests means for future improvements. First, the paper highlights the district's achievements in improving transfer education and developing new…
Conflict Management in Declining School Districts.
ERIC Educational Resources Information Center
Boyd, William Lowe; Wheaton, Dennis R.
1983-01-01
Professional literature about managing conflicts associated with declining enrollments indicates the existing tension in this area. A research study shows that, while upper-middle class districts may succeed using a rational approach to decision making, lower class districts, for various reasons, may not. Special problems of urban districts are…
Between-District Test Score Variation, 2009-2012
ERIC Educational Resources Information Center
Fahle, Erin; Reardon, Sean
2016-01-01
Describing the variation in test scores between and within school districts is critical for: (1) for policy-related and descriptive work that investigates the sorting of students among districts and the differential effectiveness of those districts; and (2) for methodological work planning future experiments or interventions. Intraclass…
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 8 2010-01-01 2010-01-01 false District. 930.6 Section 930.6 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and... Definitions § 930.6 District. District means one of the subdivisions of the production area described in § 930...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 8 2011-01-01 2011-01-01 false District. 930.6 Section 930.6 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and... Definitions § 930.6 District. District means one of the subdivisions of the production area described in § 930...
Philadelphia's Renaissance Schools Initiative after Four Years
ERIC Educational Resources Information Center
Stratos, Kati; Wolford, Tonya; Reitano, Adrienne
2015-01-01
In 2010-2011, the School District of Philadelphia (the District) launched its Renaissance Schools Initiative, a program designed to dramatically improve student achievement in the District's lowest performing schools. Some schools became Promise Academies, based on the federal turnaround model, and remained District-operated neighborhood schools.…
A Political Analysis of Community Influence over School Closure
ERIC Educational Resources Information Center
Finnigan, Kara S.; Lavner, Mark
2012-01-01
This study seeks to understand community member participation in and influence over an urban school district's school closure process. Data from interviews with School Board members, district administrators, and community members, as well as district documents and newspaper articles suggest that district administrators limited participation…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... the California State Implementation Plan, Antelope Valley Air Quality Management District and Mojave Desert Quality Management District AGENCY: Environmental Protection Agency (EPA). ACTION: Direct final... Quality Management District (AVAQMD) and Mojave Desert Air Quality Management District (MDAQMD) portion of...
20 CFR 702.272 - Informal recommendation by district director.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Informal recommendation by district director... PROCEDURE Claims Procedures Discrimination § 702.272 Informal recommendation by district director. (a) If... employer and employee accept the district director's recommendation, it will be incorporated in an order...
School District Reorganization. Educational Management Review Series Number 12.
ERIC Educational Resources Information Center
Templeton, Ian
This review surveys recent documents previously announced in RIE that are concerned with school district reorganization. The review begins with a survey of literature on three interrelated variables that affect district consolidation and redistricting -- district size, educational quality, and educational costs. Succeeding sections present a…
School District Effects and Efficiency. Special Report.
ERIC Educational Resources Information Center
Swanson, Austin D.; Engert, Frank
This paper describes efforts to develop indices of student achievement, school district effort, and school district efficiency. The challenge was to develop measures that are simple to understand, yet allow comparison among districts that are not distorted by socioeconomic differences. Measures were developed for average student achievement,…
Stakeholder Experiences in District-University Administrator Preparation Partnerships
ERIC Educational Resources Information Center
Sanzo, Karen L.; Wilson, Jacob McKinley, III
2016-01-01
Our qualitative study explores the lived experiences of district stakeholders in university-district leadership preparation programs. Collaborative partnerships between school districts and universities focused on developing quality school leader are a part of recent efforts to provide the field of public education with exemplary leadership. The…
A District Level Planning Model.
ERIC Educational Resources Information Center
McHenry, W. E.; Achilles, C. M.
This report examines school district planning models in South Carolina. It focuses on three questions: (1) Of those school districts conducting some type of systematic planning, how many are producing strategic plans? Long-range plans? Accountability reports? (2) In those same districts, how many are preparing adequate program-management…
Selected Collective Bargaining Agreements of Northern California Two-Year Colleges.
ERIC Educational Resources Information Center
National Education Association, Washington, DC.
Collective bargaining agreements between 15 selected community college districts in northern California and their faculty associations are presented, representing contracts in effect in 1987. Contracts for the following colleges and districts are included: Butte Community College District, Cabrillo Community College District, College of the…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-06
... the California State Implementation Plan, Imperial County Air Pollution Control District, Kern County Air Pollution Control District, and Ventura County Air Pollution Control District AGENCY... approve revisions to the Imperial County Air Pollution Control District (ICAPCD), Kern County Air...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-24
... the California State Implementation Plan, Placer County Air Pollution Control District and Ventura County Air Pollution Control District AGENCY: Environmental Protection Agency (EPA). ACTION: Direct final... Pollution Control District (PCAPCD) and Ventura County Air Pollution Control District (VCAPCD) portion of...
ERIC Educational Resources Information Center
General Accounting Office, Washington, DC. Health, Education, and Human Services Div.
The District of Columbia Public Schools (DCPS) is one of the largest public school districts in the United States. Since 1989-90, there have been questions about several aspects of DCPS's enrollment-count process. A valid enrollment-count process and an accurate count are critical to DCPS's district- and school-level planning, staffing, funding,…
Introducing quality management into primary health care services in Uganda.
Omaswa, F.; Burnham, G.; Baingana, G.; Mwebesa, H.; Morrow, R.
1997-01-01
In 1994, a national quality assurance programme was established in Uganda to strengthen district-level management of primary health care services. Within 18 months both objective and subjective improvements in the quality of services had been observed. In the examples documented here, there was a major reduction in maternal mortality among pregnant women referred to Jinja District Hospital, a reduction in waiting times and increased patient satisfaction at Masaka District Hospital, and a marked reduction in reported cases of measles in Arua District. Beyond these quantitative improvements, increased morale of district health team members, improved satisfaction among patients, and greater involvement of local government in the decisions of district health committees have been observed. At the central level, the increased coordination of activities has led to new guidelines for financial management and the procurement of supplies. District quality management workshops followed up by regular support visits from the Ministry of Health headquarters have led to a greater understanding by central staff of the issues faced at the district level. The quality assurance programme has also fostered improved coordination among national disease-control programmes. Difficulties encountered at the central level have included delays in carrying out district support visits and the failure to provide appropriate support. At the district level, some health teams tackled problems over which they had little control or which were overly complex; others lacked the management capacity for problem solving. PMID:9185368
Population-Based Study of Trachoma in Guatemala.
Silva, Juan Carlos; Diaz, Marco Antonio; Maul, Eugenio; Munoz, Beatriz E; West, Sheila K
2015-01-01
A prevalence survey for active trachoma in children aged under 10 years and trichiasis in women aged 40 years and older was carried out in four districts in the Sololá region in Guatemala, which is suspected of still having a trachoma problem. Population-based surveys were undertaken in three districts, within 15 randomly selected communities in each district. In addition, in a fourth district that borders the third district chosen, we surveyed the small northern sub-district, by randomly selecting three communities in each community, 100 children aged under 10 years were randomly selected, and all females over 40 years. Five survey teams were trained and standardized. Trachoma was graded using the World Health Organization simplified grading scheme and ocular swabs were taken in cases of clinical follicular or inflammatory trachoma. Prevalence estimates were calculated at district and sub-district level. Trachoma rates at district level varied from 0-5.1%. There were only two sub-districts where active trachoma approached 10% (Nahualá Costa, 8.1%, and Santa Catarina Costa, 7.3%). Trichiasis rates in females aged 40 years and older varied from 0-3%. Trachoma was likely a problem in the past. Trachoma is disappearing in the Sololá region in Guatemala. Health leadership may consider further mapping of villages around the areas with an especially high rate of trachoma and infection, and instituting trichiasis surgery and active trachoma intervention where needed.
Compressor bleed cooling fluid feed system
Donahoo, Eric E; Ross, Christopher W
2014-11-25
A compressor bleed cooling fluid feed system for a turbine engine for directing cooling fluids from a compressor to a turbine airfoil cooling system to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The compressor bleed cooling fluid feed system may enable cooling fluids to be exhausted from a compressor exhaust plenum through a downstream compressor bleed collection chamber and into the turbine airfoil cooling system. As such, the suction created in the compressor exhaust plenum mitigates boundary layer growth along the inner surface while providing flow of cooling fluids to the turbine airfoils.
School District Policies and Adolescents’ Soda Consumption
Miller, Gabrielle F.; Sliwa, Sarah; Brener, Nancy D.; Park, Sohyun; Merlo, Caitlin L.
2016-01-01
Purpose Sugar-sweetened beverages (SSBs) are a significant source of calories and added sugars for youth ages 14–18 years in the United States. This study examined the relationship between district-level policies and practices and students’ consumption of regular soda, one type of SSB, in 12 large urban school districts. Methods Data from the 2012 School Health Policies and Practices Study and 2013 Youth Risk Behavior Surveillance System were linked by district. The outcome variable was soda consumption and exposure variables were district policies. We used multivariable logistic regression analyses to calculate adjusted odds ratios (AORs) and 95% confidence intervals (CIs) after controlling for student characteristics and district free/reduced-price meal eligibility. Results About 18% of students reported consuming regular soda at least once per day. Most districts required high schools to have nutrition education, maintain closed campuses, and required/recommended that schools restrict promotional products and sale of beverages. Fewer districts required/recommended that schools offer healthful alternative beverages. Students in districts that restricted promotional products had lower odds of regular soda consumption (AOR = .84, 95% CI = .71–1.00), as did students in districts that restricted access to SSBs and offered healthful beverages when other beverages were available (AOR = .72, 95% CI = .54–.93, AOR = .76, 95% CI = .63–.91). Conclusions This study demonstrates that certain district-level policies are associated with student consumption of regular soda. These findings add to a growing consensus that policies and practices that influence the availability of healthier foods and beverages are needed across multiple settings. PMID:27021401
School District Policies and Adolescents' Soda Consumption.
Miller, Gabrielle F; Sliwa, Sarah; Brener, Nancy D; Park, Sohyun; Merlo, Caitlin L
2016-07-01
Sugar-sweetened beverages (SSBs) are a significant source of calories and added sugars for youth ages 14-18 years in the United States. This study examined the relationship between district-level policies and practices and students' consumption of regular soda, one type of SSB, in 12 large urban school districts. Data from the 2012 School Health Policies and Practices Study and 2013 Youth Risk Behavior Surveillance System were linked by district. The outcome variable was soda consumption and exposure variables were district policies. We used multivariable logistic regression analyses to calculate adjusted odds ratios (AORs) and 95% confidence intervals (CIs) after controlling for student characteristics and district free/reduced-price meal eligibility. About 18% of students reported consuming regular soda at least once per day. Most districts required high schools to have nutrition education, maintain closed campuses, and required/recommended that schools restrict promotional products and sale of beverages. Fewer districts required/recommended that schools offer healthful alternative beverages. Students in districts that restricted promotional products had lower odds of regular soda consumption (AOR = .84, 95% CI = .71-1.00), as did students in districts that restricted access to SSBs and offered healthful beverages when other beverages were available (AOR = .72, 95% CI = .54-.93, AOR = .76, 95% CI = .63-.91). This study demonstrates that certain district-level policies are associated with student consumption of regular soda. These findings add to a growing consensus that policies and practices that influence the availability of healthier foods and beverages are needed across multiple settings. Published by Elsevier Inc.
Passive wall cooling panel with phase change material as a cooling agent
NASA Astrophysics Data System (ADS)
Majid, Masni A.; Tajudin, Rasyidah Ahmad; Salleh, Norhafizah; Hamid, Noor Azlina Abd
2017-11-01
The study was carried out to the determine performance of passive wall cooling panels by using Phase Change Materials as a cooling agent. This passive cooling system used cooling agent as natural energy storage without using any HVAC system. Eight full scale passive wall cooling panels were developed with the size 1500 mm (L) × 500 mm (W) × 100 mm (T). The cooling agent such as glycerine were filled in the tube with horizontal and vertical arrangement. The passive wall cooling panels were casting by using foamed concrete with density between 1200 kg/m3 - 1500 kg/m3. The passive wall cooling panels were tested in a small house and the differences of indoor and outdoor temperature was recorded. Passive wall cooling panels with glycerine as cooling agent in vertical arrangement showed the best performance with dropped of indoor air temperature within 3°C compared to outdoor air temperature. The lowest indoor air temperature recorded was 25°C from passive wall cooling panels with glycerine in vertical arrangement. From this study, the passive wall cooling system could be applied as it was environmental friendly and less maintenance.
Barriers to District-Level Educational Reform: A Statewide Study of Minnesota School Superintendents
ERIC Educational Resources Information Center
Stewart, Courtney; Raskin, Candace; Zielaski, Daniel
2012-01-01
This study attempts to identify and describe Minnesota superintendents' perceptions of barriers to district-level reform as well as compare superintendents' perceptions of district reform related characteristics. This research also strives to identify factors preventing Minnesota's district-level leadership from implementing national reform…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-08
... Implementation Plan, Imperial County Air Pollution Control District; Final Rule #0;#0;Federal Register / Vol. 75... Implementation Plan, Imperial County Air Pollution Control District AGENCY: Environmental Protection Agency (EPA... the Imperial County Air Pollution Control District (ICAPCD or the District) portion of the California...
ERIC Educational Resources Information Center
Painter, Judith
2012-01-01
This lesson plan is based on Suzanne Collins's book, "The Hunger Games." Katniss and Gale know about District 12 and the surrounding woods. Additionally, from television coverage, they know that there are twelve districts and the Capitol. District 13 used to exist until the rebellion. But where are these districts now that the geography…
Effective Practices in High Performing Districts Serving Students in Special Education
ERIC Educational Resources Information Center
Huberman, Mette; Navo, Matt; Parrish, Tom
2012-01-01
Through a rigorous selection process based on special education performance over four years, this study identified eight unified districts in California that showed unusually strong academic performance for their special education population compared to similar districts in the state. Researchers conducted interviews with these districts' special…
Leading Implementation of 21st Century Skills: Technology
ERIC Educational Resources Information Center
Blattner, David Craig
2012-01-01
A qualitative case study was conducted on the Mooresville Graded School Districts's (MGSD) digital conversion for the entire school district. MGSD is a semi-rural small suburban school district with 5,450 students kindergarten through twelfth grade. The school district consists of three elementary schools, two intermediate schools, one middle…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-15
... the California State Implementation Plan, South Coast Air Quality Management District AGENCY... approve revisions to the South Coast Air Quality Management District (SCAQMD) portion of the California... Governor's Designee. (i) Incorporation by reference. (A) South Coast Air Quality Management District. (1...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
... California State Implementation Plan, Yolo- Solano Air Quality Management District AGENCY: Environmental...-Solano Air Quality Management District portion of the California State Implementation Plan (SIP). This... the following local rule: Yolo-Solano Air Quality Management District Rule 2.41, Expandable...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-04
... the California State Implementation Plan; South Coast Air Quality Management District AGENCY... the South Coast Air Quality Management District portion of the California State Implementation Plan... following local rule: South Coast Air Quality Management District Rule 1175, Control of Emissions from the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-28
... California State Implementation Plan, South Coast Air Quality Management District AGENCY: Environmental... revision to the South Coast Air Quality Management District (SCAQMD) portion of the California State...) * * * (411) * * * (i) * * * (F) South Coast Air Quality Management District. (1) Rule 463, ``Organic Liquid...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-25
... the California State Implementation Plan, Mojave Desert Air Quality Management District AGENCY... limited disapproval of revisions to the Mojave Desert Air Quality Management District (MDAQMD) portion of.... * * * * * (c) * * * (379) * * * (i) * * * (E) Mojave Desert Air Quality Management District. (1) Rule 1159...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
... California State Implementation Plan; Yolo-Solano Air Quality Management District AGENCY: Environmental... revision to the Yolo-Solano Air Quality Management District portion of the California State Implementation...-Solano Air Quality Management District (YSAQMD) Rule 2.41, adopted on September 10, 2008, and submitted...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-29
... the California State Implementation Plan, Yolo- Solano Air Quality Management District AGENCY... the Yolo-Solano Air Quality Management District (YSAQMD) portion of the California State...) * * * (i) * * * (C) Yolo Solano Air Quality Management District (1) Rule 3.21, ``Rice Straw Emission...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-26
...] Revisions to the California State Implementation Plan, South Coast Air Quality Management District AGENCY... the South Coast Air Quality Management District (SCAQMD) portion of the California State...'s Designee. (i) Incorporation by Reference. (A) South Coast Air Quality Management District. (1...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... the California State Implementation Plan, Feather River Air Quality Management District AGENCY... limited disapproval of revisions to the Feather River Air Quality Management District (FRAQMD) portion of.... * * * * * (c) * * * (378) * * * (i) * * * (E) Feather River Air Quality Management District. (1) Rule 3.22...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-10
... the California State Implementation Plan, Yolo- Solano Air Quality Management District AGENCY... approve revisions to the Yolo-Solano Air Quality Management District (YSAQMD) portion of the California... Identification of plan. * * * * * (c) * * * (377) * * * (i) * * * (B) Yolo Solano Air Quality Management District...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-18
... the California State Implementation Plan, Yolo- Solano Air Quality Management District AGENCY... approve revisions to the Yolo-Solano Air Quality Management District (Yolo-Solano AQMD) portion of the.... * * * * * (381) * * * (i) * * * (I) Yolo-Solano Air Quality Management District. (1) Rule 2.3, ``Ringelmann Chart...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
... the California State Implementation Plan, Antelope Valley Air Quality Management District, Santa Barbara County Air Pollution Control District, South Coast Air Quality Management District and Ventura.... SUMMARY: EPA is finalizing approval of revisions to the Antelope Valley Air Quality Management District...
Rural Gifted Education and the Effect of Proximity
ERIC Educational Resources Information Center
Puryear, Jeb S.; Kettler, Todd
2017-01-01
Gifted education services in rural districts typically lag behind those in nonrural areas. Using district classifications assigned by the National Center for Education Statistics and Texas school district data (n = 1,029) from the Academic Excellence Indicator System, the role of school district classification on gifted education outcomes was…
76 FR 30739 - Notice of Public Meeting, Salem District Resource Advisory Committee Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-26
.... ADDRESSES: BLM Salem District Office, 1717 Fabry Road, SE., Salem, OR 97306. FOR FURTHER INFORMATION CONTACT... Hatfield, BLM Salem District Designated Official, 1717 Fabry Road, SE., Salem, OR 97306--(503) 375-5682... quality, land health, forest ecosystems, and infrastructure. Miles R. Brown, BLM Salem District Manager...
Alternative Fuels Data Center: Minnesota School District Finds Cost
Savings, Cold-Weather Reliability with Propane Buses Minnesota School District Finds Cost Center: Minnesota School District Finds Cost Savings, Cold-Weather Reliability with Propane Buses on Facebook Tweet about Alternative Fuels Data Center: Minnesota School District Finds Cost Savings, Cold
Alternative Fuels Data Center: Mesa Unified School District Reaps Economic
and Environmental Benefits with Propane Buses Mesa Unified School District Reaps Economic and School District Reaps Economic and Environmental Benefits with Propane Buses on Facebook Tweet about Alternative Fuels Data Center: Mesa Unified School District Reaps Economic and Environmental Benefits with
ERIC Educational Resources Information Center
Wisconsin State Dept. of Public Instruction, Madison.
To demonstrate career education methods and procedures, seven Wisconsin school districts were chosen to participate in an incremental improvement project. Project activities were conducted district-wide and by individual districts. District-wide dissemination activities involved promoting demonstration packets and assessment/evaluation (AE)…
Oregon School Bond Manual. Seventh Edition.
ERIC Educational Resources Information Center
Oregon State Dept. of Education, Salem.
To help school districts comply with Oregon's school bond laws, this manual provides guidelines for school district attorneys and personnel in the issuance and sale of school district bonds. The manual deals with the three primary types of Oregon school district borrowings: (1) general obligation bonds; (2) tax and revenue anticipation notes; and…
ERIC Educational Resources Information Center
Hornung, Katie; Yoder, Nick
2014-01-01
In the wake of the Common Core State Standards and teacher evaluation reform, school leaders increasingly look to district leaders for support, coaching, and leadership. District leaders--superintendents, assistant or area superintendents, specialists, principal supervisors, and school business administrators--can hold varying and multiple roles…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-07
...: The proposed Three Sisters Irrigation District Hydroelectric Project would be located on the north pipe of the Three Sisters Irrigation District's Main Canal Pipeline in Deschutes County, Oregon. The... of Project: The Three Sisters Irrigation District Hydroelectric Project would consist of: (1) An...
California's Districts of Choice
ERIC Educational Resources Information Center
Kronholz, June
2014-01-01
This article describes the results of a California state law established in 2010 that created "Districts of Choice." The District of Choice law was meant to encourage districts to compete for students by offering innovative programs and this-school-fits-my-child options that parents wanted. This designation meant that children from any…
Collaborating with the Community: Lessons from a Rural School District
ERIC Educational Resources Information Center
Walker, Anne
2012-01-01
This article, based on case study research, highlights how a rural school district in the midwestern United States collaborated with local community organizations to meet the needs of English language learners after the district and community experienced rapid ethnic diversification. In particular, the district EL coordinator spearheaded the…
District Support of School Improvement: Highlights from Three Districts. Newsletter
ERIC Educational Resources Information Center
Center for Comprehensive School Reform and Improvement, 2009
2009-01-01
This newsletter addresses various supports that districts are utilizing to help keep students in school and on the path to graduation. Described herein are three districts that have been particularly successful in raising student achievement--even though they differ in their specific strategies, fund allocation, and demographic composition. A…
San Jose/Evergreen Community College District: Governing Board's Strategic Master Plan.
ERIC Educational Resources Information Center
San Jose/Evergreen Community Coll. District, San Jose, CA.
This report presents San Jose/Evergreen Community College District Governing Board's Strategic Master Plan. This report summarizes the district's mission statement, goal statements, and board priorities. The San Jose/Evergreen Community College District is committed to providing open access and opportunity for success to its multi-ethnic…
District Consolidation: Rivals Coming Together
ERIC Educational Resources Information Center
Mart, Dan
2011-01-01
District consolidation is a highly emotional process. One key to success is sticking to the facts. In Iowa, school districts facing financial difficulties or enrollment concerns do not have to move directly to consolidation. In many cases, districts begin by developing sharing agreements. These sharing agreements may start with simple sharing of…
27 CFR 9.166 - Diamond Mountain District.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Diamond Mountain District... Diamond Mountain District. (a) Name. The name of the viticultural area described in this section is “Diamond Mountain District.” (b) Approved map. The appropriate maps for determining the boundary of the...
27 CFR 9.166 - Diamond Mountain District.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Diamond Mountain District... Diamond Mountain District. (a) Name. The name of the viticultural area described in this section is “Diamond Mountain District.” (b) Approved map. The appropriate maps for determining the boundary of the...
27 CFR 9.166 - Diamond Mountain District.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Diamond Mountain District... Diamond Mountain District. (a) Name. The name of the viticultural area described in this section is “Diamond Mountain District.” (b) Approved map. The appropriate maps for determining the boundary of the...
ERIC Educational Resources Information Center
Ralston, Nicole; Weitzel, Bruce; Waggoner, Jacqueline; Naegele, Zulema; Smith, Rebecca
2016-01-01
There has been a recent shift in university-district partnership models from traditional transactional partnerships, which lack a shared purpose, to transformational partnerships that are mutually beneficial to both universities and school districts. These transformational research-practice partnerships have gained popularity in the United States…
Estimating the Efficiency of Michigan's Rural and Urban Public School Districts
ERIC Educational Resources Information Center
Maranowski, Rita
2012-01-01
This study examined student achievement in Michigan public school districts to determine if rural school districts are demonstrating greater financial efficiency by producing higher levels of student achievement than school districts in other geographic locations with similar socioeconomics. Three models were developed using multiple regression…
Comparing District Achievement to Improve Decision Making in Clark County, Nevada. Vignette
ERIC Educational Resources Information Center
American Institutes for Research, 2012
2012-01-01
In response to changing demographics, a tightening budget, and drastic achievement gaps (white students outperform Latino students on standardized tests) the Clark County School District in Nevada (the fifth largest district in the country) commissioned, in 2011, an educational and operational efficiency review. The district commissioned the…
77 FR 43353 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) and...: On August 16, 2012, the Twin Falls District RAC subcommittee members for the proposed Monument and...
75 FR 60477 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-30
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... (BLM) Twin Falls District Resource Advisory Council (RAC) subcommittee for the Jarbidge Draft Resource...; and December 1, 2010. The Twin Falls District RAC subcommittee members will meet at the Loong Hing...
75 FR 48723 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-11
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... (BLM) Twin Falls District Resource Advisory Council (RAC) and subcommittees will meet as indicated below. DATES: On September 9, 2010, the Twin Falls District RAC subcommittee members will meet at the...
77 FR 37705 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) and...: On July 10, 2012, the Twin Falls District RAC subcommittee members for the proposed Monument and...
77 FR 15388 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-15
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) and...: On March 28, 2012, the Twin Falls District RAC subcommittee members for the proposed Monument and...
75 FR 80839 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-23
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... (BLM) Twin Falls District Resource Advisory Council (RAC) and subcommittee for the Jarbidge Resource... 12, 2011, the Twin Falls District RAC subcommittee members will meet at the Loong Hing Restaurant...
77 FR 48168 - Call for Nominations for the Twin Falls District Resource Advisory Council
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-13
... for Nominations for the Twin Falls District Resource Advisory Council AGENCY: Bureau of Land Management, Interior. ACTION: Call for Nominations, Twin Falls District Resource Advisory Council SUMMARY: This notice requests public nominations to fill one position on the Twin Falls District Resource...
77 FR 17093 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... Public Meeting, Idaho Falls District Resource Advisory Council AGENCY: Bureau of Land Management... Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Salmon, Idaho on April 24-25...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-02
...: Baldwin-White Cloud Districts: Lake County Star, published weekly in Baldwin, Lake County, Michigan..., Missouri District Ranger Decisions: Ava/Cassville/Willow Springs District: Springfield News-Leader... Virginia Marlinton-White Sulphur District: The Pocahontas Times, published weekly In Marlinton, Pocahontas...
29 CFR 1610.4 - Public reference facilities and current index.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (New York District), 1 Newark Center, 21st Floor, Newark, NJ 07102-5233. New Orleans Field Office (Houston District), 1555 Poydras, Suite 1900, New Orleans, LA 70112. New York District Office, 33 Whitehall..., Birmingham, AL 35205-2397. Boston Area Office (New York District), John F. Kennedy Federal Building...
Sharing Local Revenue: One District's Perspective
ERIC Educational Resources Information Center
Cline, David S.
2011-01-01
The vast majority of U.S. school districts are considered independent and have taxing authority; the remaining districts rely on revenue and budgetary approval from their local government. In the latter case, localities often use some form of negotiated process to determine the amount of revenue their school districts will receive. Typically, a…
25 CFR 215.23 - Cooperation between superintendent and district mining supervisor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Cooperation between superintendent and district mining... MINERALS LEAD AND ZINC MINING OPERATIONS AND LEASES, QUAPAW AGENCY § 215.23 Cooperation between superintendent and district mining supervisor. (a) The district mining supervisor of the Miami field office...
Developing, Managing, and Gaining Public Support for the School District Budget.
ERIC Educational Resources Information Center
Holly, William J.
1987-01-01
This bulletin focuses on four aspects of budget development and management in local school districts. Chapter 1 describes the general budget development process, highlighting variations some Oregon districts have found useful. The chapter outlines the responsibilities of educational agencies and district staff members at various levels and reviews…
Statewide Community College Employee Benefit Consortium.
ERIC Educational Resources Information Center
Guy, Jerry T.
Health insurance benefit programs in Texas community college districts fall into three groups. Comprising 25% of the districts, districts fall into three groups. Comprising 25% of the districts, the "help me now" group has experienced heavy group health insurance benefit utilization over the past few years and is unable to purchase required…
20 CFR 422.5 - District offices and branch offices.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false District offices and branch offices. 422.5... and Functions of the Social Security Administration § 422.5 District offices and branch offices. There are over 700 social security district offices and branch offices located in the principal cities and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-21
...] Huron, Madison, and Sand Lake Wetland Management District; Comprehensive Conservation Plan AGENCY: Fish... (CCP) and environmental assessment (EA) for the Huron, Madison, and Sand Lake Wetland Management...), Madison Wetland Management District, and Sand Lake Wetland Management District are part of the National...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-10
... Quality Implementation Plans; California; South Coast Air Quality Management District; Prevention of... Implementation Plan (SIP) revision for the South Coast Air Quality Management District (SCAQMD or District... in a August 15, 2012 letter from the South Coast Air Quality Management District regarding specific...
Code of Federal Regulations, 2014 CFR
2014-01-01
... District shall include all the counties in the State of Oregon except for Hood River and Wasco counties. (2) Mid-Columbia District shall include Hood River and Wasco counties in the State of Oregon, and the counties of Skamania and Klickitat in the State of Washington. (3) Wenatchee District shall include the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... District shall include all the counties in the State of Oregon except for Hood River and Wasco counties. (2) Mid-Columbia District shall include Hood River and Wasco counties in the State of Oregon, and the counties of Skamania and Klickitat in the State of Washington. (3) Wenatchee District shall include the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... District shall include all the counties in the State of Oregon except for Hood River and Wasco counties. (2) Mid-Columbia District shall include Hood River and Wasco counties in the State of Oregon, and the counties of Skamania and Klickitat in the State of Washington. (3) Wenatchee District shall include the...
Code of Federal Regulations, 2013 CFR
2013-01-01
... District shall include all the counties in the State of Oregon except for Hood River and Wasco counties. (2) Mid-Columbia District shall include Hood River and Wasco counties in the State of Oregon, and the counties of Skamania and Klickitat in the State of Washington. (3) Wenatchee District shall include the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... District shall include all the counties in the State of Oregon except for Hood River and Wasco counties. (2) Mid-Columbia District shall include Hood River and Wasco counties in the State of Oregon, and the counties of Skamania and Klickitat in the State of Washington. (3) Wenatchee District shall include the...
Kentucky's Program for Educationally Deficient School Districts: A Case Study.
ERIC Educational Resources Information Center
Fry, Patricia; And Others
The development and implementation of Kentucky's Program for Educationally Deficient School Districts is examined in this case study. Implemented in 1987, the program required districts to meet certain performance, planning, and reporting criteria. Districts failing to comply could be placed in categories of noncompliance. Data were derived from…
Low pressure cooling seal system for a gas turbine engine
Marra, John J
2014-04-01
A low pressure cooling system for a turbine engine for directing cooling fluids at low pressure, such as at ambient pressure, through at least one cooling fluid supply channel and into a cooling fluid mixing chamber positioned immediately downstream from a row of turbine blades extending radially outward from a rotor assembly to prevent ingestion of hot gases into internal aspects of the rotor assembly. The low pressure cooling system may also include at least one bleed channel that may extend through the rotor assembly and exhaust cooling fluids into the cooling fluid mixing chamber to seal a gap between rotational turbine blades and a downstream, stationary turbine component. Use of ambient pressure cooling fluids by the low pressure cooling system results in tremendous efficiencies by eliminating the need for pressurized cooling fluids for sealing this gap.
Liang, George
2010-10-26
A blade is provided for a gas turbine. The blade comprises a main body comprising a cooling fluid entrance channel; a cooling fluid collector in communication with the cooling fluid entrance channel; a plurality of side channels extending through an outer wall of the main body and communicating with the cooling fluid collector and a cooling fluid cavity; a cooling fluid exit channel communicating with the cooling fluid cavity; and a plurality of exit bores extending from the cooling fluid exit channel through the main body outer wall.
Cooling for a rotating anode X-ray tube
Smither, Robert K.
1998-01-01
A method and apparatus for cooling a rotating anode X-ray tube. An electromagnetic motor is provided to rotate an X-ray anode with cooling passages in the anode. These cooling passages are coupled to a cooling structure located adjacent the electromagnetic motor. A liquid metal fills the passages of the cooling structure and electrical power is provided to the motor to rotate the anode and generate a rotating magnetic field which moves the liquid metal through the cooling passages and cooling structure.
Fuel Cell Thermal Management Through Conductive Cooling Plates
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; Burke, Kenneth A.
2008-01-01
An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.
Pretorius, Thea; Lix, Lisa; Giesbrecht, Gordon
2011-03-01
Previous studies showed that core cooling rates are similar when only the head or only the body is cooled. Structural equation modeling was used on data from two cold water studies involving body-only, or whole body (including head) cooling. Exposure of both the body and head increased core cooling, while only body cooling elicited shivering. Body fat attenuates shivering and core cooling. It is postulated that this protection occurs mainly during body cooling where fat acts as insulation against cold. This explains why head cooling increases surface heat loss with only 11% while increasing core cooling by 39%. Copyright © 2011 Elsevier Ltd. All rights reserved.
Rep. Norton, Eleanor Holmes [D-DC-At Large
2011-03-17
House - 04/01/2011 Referred to the Subcommittee on Health Care, District of Columbia, Census and the National Archives. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
NASA Technical Reports Server (NTRS)
Faulkner, F. E.
1971-01-01
A study was conducted to determine the effect of chord size on air cooled turbine blades. In the preliminary design phase, eight turbine blade cooling configurations in 0.75-in., 1.0-in., and 1.5-in. chord sizes were analyzed to determine the maximum turbine inlet temperature capabilities. A pin fin convection cooled configuration and a film-impingement cooled configuration were selected for a final design analysis in which the maximum turbine inlet temperature was determined as a function of the cooling air inlet temperature and the turbine inlet total pressure for each of the three chord sizes. The cooling air flow requirements were also determined for a varying cooling air inlet temperature with a constant turbine inlet temperature. It was determined that allowable turbine inlet temperature increases with increasing chord for the convection cooled and transpiration cooled designs, however, the film-convection cooled designs did not have a significant change in turbine inlet temperature with chord.
Development and Experimental Evaluation of Passive Fuel Cell Thermal Control
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; Jakupca, Ian J.; Castle, Charles H.; Burke, Kenneth A.
2014-01-01
To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.
Turbine airfoil with an internal cooling system having vortex forming turbulators
Lee, Ching-Pang
2014-12-30
A turbine airfoil usable in a turbine engine and having at least one cooling system is disclosed. At least a portion of the cooling system may include one or more cooling channels having a plurality of turbulators protruding from an inner surface and positioned generally nonorthogonal and nonparallel to a longitudinal axis of the airfoil cooling channel. The configuration of turbulators may create a higher internal convective cooling potential for the blade cooling passage, thereby generating a high rate of internal convective heat transfer and attendant improvement in overall cooling performance. This translates into a reduction in cooling fluid demand and better turbine performance.
Photodetachment and Doppler laser cooling of anionic molecules
NASA Astrophysics Data System (ADS)
Gerber, Sebastian; Fesel, Julian; Doser, Michael; Comparat, Daniel
2018-02-01
We propose to extend laser-cooling techniques, so far only achieved for neutral molecules, to molecular anions. A detailed computational study is performed for {{{C}}}2- molecules stored in Penning traps using GPU based Monte Carlo simulations. Two cooling schemes—Doppler laser cooling and photodetachment cooling—are investigated. The sympathetic cooling of antiprotons is studied for the Doppler cooling scheme, where it is shown that cooling of antiprotons to subKelvin temperatures could becomes feasible, with impacts on the field of antimatter physics. The presented cooling schemes also have applications for the generation of cold, negatively charged particle sources and for the sympathetic cooling of other molecular anions.
NASA Technical Reports Server (NTRS)
Miley, S. J.; Cross, E. J., Jr.; Owens, J. K.; Lawrence, D. L.
1981-01-01
A flight-test based research program was performed to investigate the aerodynamics and cooling of a horizontally-opposed engine installation. Specific areas investigated were the internal aerodynamics and cooling mechanics of the installation, inlet aerodynamics, and exit aerodynamics. The applicable theory and current state of the art are discussed for each area. Flight-test and ground-test techniques for the development of the cooling installation and the solution of cooling problems are presented. The results show that much of the internal aerodynamics and cooling technology developed for radial engines are applicable to horizontally opposed engines. Correlation is established between engine manufacturer's cooling design data and flight measurements of the particular installation. Also, a flight-test method for the development of cooling requirements in terms of easily measurable parameters is presented. The impact of inlet and exit design on cooling and cooling drag is shown to be of major significance.
Controlled cooling of an electronic system for reduced energy consumption
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
Energy efficient control of a cooling system cooling an electronic system is provided. The control includes automatically determining at least one adjusted control setting for at least one adjustable cooling component of a cooling system cooling the electronic system. The automatically determining is based, at least in part, on power being consumed by the cooling system and temperature of a heat sink to which heat extracted by the cooling system is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the coolingmore » system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on one or more experimentally obtained models relating the targeted temperature and power consumption of the one or more adjustable cooling components of the cooling system.« less
[Health status and living conditions in medical district of Sandnes during the period 1866-1900].
Helgaland, T; Rosvold, E O
1999-12-10
The municipality of Sandnes became a separate medical district in 1866. The district physicians' reports give us an insight into health and living conditions in this district in the last half of the 19th century. This paper is based on a study of all statistical data and physicians' comments concerning the Sandnes district for the 1866-1900 period. The incidence of various diseases is estimated. Mental illness seems to have been more frequent in Sandness than in the rest of the county. In the physicians' reports, this was explained by the dominance of religious Puritanism in the district. The incidence of other disease, such as typhoid fever, tuberculosis and scarlet fever, did not differ essentially between Sandnes and the county as a whole. The living conditions in the district were rather good during the whole period, though the physicians' reports provide interesting insight in changes from one year to another.
School district resources and identification of children with autistic disorder.
Palmer, Raymond F; Blanchard, Stephen; Jean, Carlos R; Mandell, David S
2005-01-01
We estimated the effect of community and school district resources on the identification of children with autistic disorder. Latent growth curve regression models were applied to school district-level data from one large state. The rate of identification of autistic disorder increased on average by 1.0 child per 10000 per year (P<.001), with statistically significant district variation. After adjustment for district and community characteristics, each increase in decile of school revenue was associated with an increase of 0.16 per 10000 children identified with autistic disorder. The proportion of economically disadvantaged children per district was inversely associated with autistic disorder cases. District revenue was associated with higher proportions of children identified with autistic disorder at baseline and increasing rates of identification when measured longitudinally. Economically disadvantaged communities may need assistance to identify children with autistic spectrum disorders and other developmental delays that require attention.
NASA Astrophysics Data System (ADS)
Tombolotutu, A. D.; Djirimu, M. A.; Lutfi, M.; Anggadini, F.
2018-05-01
Research was conducted in several districts/city in Central Sulawesi Province in order to determine the effect of life expectancy, literacy rate, opened unemployment rate, and gross domestic regional income per capita on poverty at the districts/city in the province. The analysis used is Panel Data Regression. The results show that first, life expectancy and gross domestic regional income have a negative and significant impact on the poverty level in the districts/city in the Province. Second, the opened unemployment rate has a positive and significant effect on the poverty level in the districts/city in the province. Third, literacy rates show a positive effect and insignificant effect on the poverty level in the districts/city in the Province of Central Sulawesi. Fourth, these four variables simultaneously affect the poverty in the districts/city in Central Sulawesi
Superintendent Response to the Financial Downturn
ERIC Educational Resources Information Center
Starrett, Teresa Martin; Casey, Pat; Dunlap, Karen
2014-01-01
In this study, 79 local school district leaders from the state of Texas were contacted and asked for their input relating to strategic practices used during an economic downturn. Findings describe how the recent funding cuts affected the varied districts; how the districts fared in comparison with similar districts in the area; steps the district…
ERIC Educational Resources Information Center
Busch, Douglas M.
2012-01-01
As school district revenues are reduced by state allocating agencies, local school district administrators and school boards frequently evaluate alternative sources of possible revenue. One emerging source of revenue that many school districts explore is a local education foundation. Local education foundations are 501(c)(3) nonprofit…
Universal Design for Learning and the Port Jefferson School District: A Needs Assessment
ERIC Educational Resources Information Center
Sladek-Maharg, Tara S.
2011-01-01
Purpose: This applied doctoral project purpose was to determine what was needed to implement UDL in the Port Jefferson school district, specifically determining district strengths and weaknesses. Data were collected with researcher-created surveys given to administrators, faculty members, and members of the parent organizations and the district's…
8 CFR 280.11 - Notice of intention to fine; procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the triplicate copy shall be delivered directly to the district director of customs for the district in which the vessel or aircraft is located, and the district director of customs shall withhold... vessel or aircraft is located in a customs district which is outside the jurisdiction of the office of...
8 CFR 280.11 - Notice of intention to fine; procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the triplicate copy shall be delivered directly to the district director of customs for the district in which the vessel or aircraft is located, and the district director of customs shall withhold... vessel or aircraft is located in a customs district which is outside the jurisdiction of the office of...
8 CFR 1280.11 - Notice of intention to fine; procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... copy shall be delivered directly to the district director of customs for the district in which the vessel or aircraft is located, and the district director of customs shall withhold clearance until... aircraft is located in a customs district which is outside the jurisdiction of the office of the Service...
8 CFR 280.11 - Notice of intention to fine; procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the triplicate copy shall be delivered directly to the district director of customs for the district in which the vessel or aircraft is located, and the district director of customs shall withhold... vessel or aircraft is located in a customs district which is outside the jurisdiction of the office of...
8 CFR 280.11 - Notice of intention to fine; procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the triplicate copy shall be delivered directly to the district director of customs for the district in which the vessel or aircraft is located, and the district director of customs shall withhold... vessel or aircraft is located in a customs district which is outside the jurisdiction of the office of...
8 CFR 280.11 - Notice of intention to fine; procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the triplicate copy shall be delivered directly to the district director of customs for the district in which the vessel or aircraft is located, and the district director of customs shall withhold... vessel or aircraft is located in a customs district which is outside the jurisdiction of the office of...
Code of Federal Regulations, 2013 CFR
2013-04-01
...), the District of Columbia, the Commonwealth of Puerto Rico, and United States territories, considered... States (and their political subdivisions), the District of Columbia, the Commonwealth of Puerto Rico, and.... The District of Columbia, the Commonwealth of Puerto Rico, Guam, the Virgin Islands, and territories...
Code of Federal Regulations, 2012 CFR
2012-04-01
...), the District of Columbia, the Commonwealth of Puerto Rico, and United States territories, considered... States (and their political subdivisions), the District of Columbia, the Commonwealth of Puerto Rico, and.... The District of Columbia, the Commonwealth of Puerto Rico, Guam, the Virgin Islands, and territories...
Code of Federal Regulations, 2011 CFR
2011-04-01
...), the District of Columbia, the Commonwealth of Puerto Rico, and United States territories, considered... States (and their political subdivisions), the District of Columbia, the Commonwealth of Puerto Rico, and.... The District of Columbia, the Commonwealth of Puerto Rico, Guam, the Virgin Islands, and territories...
Code of Federal Regulations, 2014 CFR
2014-04-01
...), the District of Columbia, the Commonwealth of Puerto Rico, and United States territories, considered... States (and their political subdivisions), the District of Columbia, the Commonwealth of Puerto Rico, and.... The District of Columbia, the Commonwealth of Puerto Rico, Guam, the Virgin Islands, and territories...
Code of Federal Regulations, 2010 CFR
2010-04-01
...), the District of Columbia, the Commonwealth of Puerto Rico, and United States territories, considered... States (and their political subdivisions), the District of Columbia, the Commonwealth of Puerto Rico, and.... The District of Columbia, the Commonwealth of Puerto Rico, Guam, the Virgin Islands, and territories...
Politics First: Examining the Practice of the Multi-District Superintendent
ERIC Educational Resources Information Center
Hall, Daniella; McHenry-Sorber, Erin
2017-01-01
Over the past decade, multiple states have implemented a form of regional school district consolidation referred to as multi-district unions. Their organizational structure enables districts to retain individual school boards within regional local education agencies, all of which are overseen by a superintendent and a central board. However, no…
ERIC Educational Resources Information Center
Sun, Min; Youngs, Peter
2009-01-01
This study used Hierarchical Multivariate Linear models to investigate relationships between principals' behaviors and district principal evaluation purpose, focus, and assessed leadership activities in 13 school districts in Michigan. The study found that principals were more likely to engage in learning-centered leadership behaviors when the…
How State Takeover School Districts Shake Up Teacher Professional Development
ERIC Educational Resources Information Center
Pennington, Kaitlin
2014-01-01
Over the past few decades, many state departments of education have taken over low-performing schools or districts as a school turnaround strategy. Recently, that strategy has shifted to creating new districts--managed by the state--that include schools and parts of districts that face challenges in performance. The governance structure brings…
Comprehensive Profile of the San Antonio Indepentent School District 1983-1984.
ERIC Educational Resources Information Center
San Antonio Independent School District, TX.
This report presents statistical data about the San Antonio (Texas) Independent School District for the 1983-1984 school year. Trends for five or ten year groupings of past years are also presented. The report consolidates both district and individual school information from regular reports by the different district departments. The data is…
Governing Urban School Districts: Efforts in Los Angeles to Effect Change
ERIC Educational Resources Information Center
Augustine, Catherine H.; Epstein, Diana; Vuollo, Mirka
2006-01-01
Many urban school district students are dropping out and few of the remaining ones reach state or district achievement goals. These problems make governing urban schools both difficult and important. In 2005-06, the governance structure of the Los Angeles Unified School District (LAUSD) was examined, debated, criticized, and praised by several…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-20
... the California State Implementation Plan, South Coast Air Quality Management District AGENCY... approve a revision to the South Coast Air Quality Management District (SCAQMD) portion of the California... Reference (A) South Coast Air Quality Management District (1) Rule 2005, ``New Source Review for RECLAIM...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-04
... California State Implementation Plan; South Coast Air Quality Management District AGENCY: Environmental... revision to the South Coast Air Quality Management District portion of the California State Implementation... Submittal A. What rule did the State submit? We are approving South Coast Air Quality Management District...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
... the California State Implementation Plan, Mojave Desert Air Quality Management District AGENCY... approve revisions to the Mojave Desert Air Quality Management District (MDAQMD) portion of the California... approving with the dates that they were adopted by the Mojave Desert Air Quality Management District (MDAQMD...
The Alpha and Omega Syndrome: Is Intra-District Funding the next Ripeness Factor?
ERIC Educational Resources Information Center
Owings, William A.; Kaplan, Leslie S.
2010-01-01
Fiscal disparities within school districts may be the next area "ripe" for litigation. Equity and adequacy litigation have largely focused on between-district fiscal disparities. Research suggests that within-district disparities may be as unfair to high poverty schools. When the school funding pie is not growing, remedying…
ERIC Educational Resources Information Center
Socias, Miguel; deSousa, Juliette-Marie; Le Floch, Kerstin Carlson
2009-01-01
Under federal regulations, school districts that have been identified for improvement or corrective action are not eligible to be supplemental educational service providers. However, the U.S. Department of Education granted waivers to five such districts, on a pilot basis, to allow those districts to provide supplemental educational services. Two…
76 FR 53678 - Calleguas Municipal Water District Notice of Surrender of Exemption (Conduit)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-29
... Municipal Water District Notice of Surrender of Exemption (Conduit) Pursuant to section 4.95(a) of the Commission's regulations,\\1\\ Calleguas Municipal Water District filed with the Commission a petition to... Municipal Water District, 87 FERC ] 62,256 (1999). \\3\\ See filing of July 11, 2011 by Calleguas Municipal...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-20
.... Project No.: 11572-001. c. Date Initiated: January 9, 2012. d. Exemptee: Roosevelt Water Conservation District. e. Name and Location of Project: The Roosevelt Water Conservation District Conduit Hydropower..., Roosevelt Water Conservation District, 2344 S. Higley Road, Gilbert, AZ 82595-4794, (480) 988-9586. [[Page...
ERIC Educational Resources Information Center
Hoffman, Pamela K.; Davey, Cynthia S.; Larson, Nicole; Grannon, Katherine Y.; Hanson, Carlie; Nanney, Marilyn S.
2016-01-01
Weight-related outcomes were examined among high school students in Minnesota public school districts according to the quality of district wellness policies. Wellness policy strength and comprehensiveness were scored using the Wellness School Assessment Tool (WellSAT) for 325 Minnesota public school districts in 2013. The associations between…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
...-Fort Rock Ranger District; Oregon; Withdrawal of Notice for Preparation of an Environmental Impact... Administration, USDOT. ACTION: Notice of withdrawal. SUMMARY: The Bend-Fort Rock Ranger District and FHWA are..., Project Leader, Bend- Fort Rock Ranger District, 63095 Deschutes Market Road, Bend, OR 97701, phone 541...
No One Way: Differentiating School District Leadership and Support for School Improvement
ERIC Educational Resources Information Center
Anderson, Stephen E.; Mascall, Blair; Stiegelbauer, Suzanne; Park, Jaddon
2012-01-01
This article examines findings from a qualitative investigation of how school district administrators in four mid to large sized urban school districts (10,000-50,000) identify and address differences in school performance. The analysis explores the interaction between district policies and actions that centralize and standardize expectations for…
National Television News in Seven Rural Districts. Report 96-2.
ERIC Educational Resources Information Center
Nasstrom, Roy; Gierok, Anne
The implementation, delivery, and impact on students of news programs delivered to schools by Channel One and CNN-Newsroom were examined in seven rural districts in Wisconsin. Investigation covered three districts using CNN and four districts using Channel One within a three-county area. Involved administrators, teachers, and students responded to…
Are Social Networking Websites Educational? Information Capsule. Volume 0909
ERIC Educational Resources Information Center
Blazer, Christie
2009-01-01
More and more school districts across the country are joining social networking sites, such as Facebook and MySpace. This Information Capsule discusses the frequency with which school districts are using social networking sites, how districts are using the sites, and potential drawbacks associated with their use. Issues for districts to consider…
San Diego Community College District Reprographic Services Study.
ERIC Educational Resources Information Center
Beuhner, Sandra
In 1981 a study was conducted at the San Diego Community College District to: (1) identify the types and quantity of internal reprographic services currently being provided in the District; (2) identify the types of services for which the District was contracting with outside printers; (3) provide an inventory of reprographic equipment in the…
School District Consolidation: The Benefits and Costs
ERIC Educational Resources Information Center
Duncombe, William D.; Yinger, John M.
2010-01-01
School district consolidation is a striking phenomenon. According to the National Center for Education Statistics, 117,108 school districts provided elementary and secondary education in 1939-1940. By 2006-2007, the number of districts had dropped to 13,862, a decline of 88 percent. The rate of consolidation has slowed in recent years, but at…
Research Use by Leaders in Canadian School Districts
ERIC Educational Resources Information Center
Cooper, Amander; Levin, Ben
2013-01-01
This paper, part of a larger study, investigates the ways research is used by leaders in Canadian schools and districts, an area in which there is relatively little empirical evidence. The paper analyzes survey results from 188 education leaders in 11 school districts across Canada about school and district practices related to the use of…
Conceptions of Evidence Use in School Districts: Mapping the Terrain
ERIC Educational Resources Information Center
Coburn, Cynthia E.; Talbert, Joan E.
2006-01-01
Current policies place unprecedented demands on districts to use evidence to guide their educational improvement efforts. How districts respond is likely to be influenced by how individuals in the district conceptualize what it means to use evidence in their ongoing work. This study draws on sensemaking and institutional theory to investigate how…
Pewaukee School District, Wisconsin. Case Study: Measures of Academic Progress
ERIC Educational Resources Information Center
Northwest Evaluation Association, 2015
2015-01-01
For more than a decade, Pewaukee School District Superintendent JoAnn Sternke has watched her district get better and better at its mission: opening the door to each student's future. The Wisconsin district began using Measures of Academic Progress® (MAP®) computer adaptive interim assessments from Northwest Evaluation Association™ (NWEA™) in 2004…
District Self-Assessment Tool. College Readiness Indicator Systems Resource Series
ERIC Educational Resources Information Center
Annenberg Institute for School Reform at Brown University, 2014
2014-01-01
The purpose of the "District Self-Assessment Tool" is to provide school district and community stakeholders with an approach for assessing district capacity to support a college readiness indicator system and track progress over time. The tool draws on lessons from the collective implementation experiences of the four College Readiness…
Which Districts Get into Financial Trouble and Why: Michigan's Story
ERIC Educational Resources Information Center
Arsen, David; DeLuca, Thomas; Ni, Yongmei; Bates, Michael
2016-01-01
Like other states, Michigan has implemented a number of policies to change governance and administrative arrangements in local school districts deemed to be in financial emergency. This paper examines two questions: (1) Which districts get into financial trouble and why? and (2) Among fiscally distressed districts, are there significant…
ERIC Educational Resources Information Center
Psencik, Kay; Baldwin, Rhonda
2012-01-01
In 2010, district leaders of Douglas County Public Schools, Douglasville, Georgia, launched an ambitious initiative to ensure that teachers set goals that focus on increasing their effectiveness and show student growth. To achieve this goal, the district leadership team focused on common district assessments to establish common learning…
Abbott Students Attending Charter Schools: Funding Disparities and Legal Implications
ERIC Educational Resources Information Center
Bulkley, Katrina
2007-01-01
Most of New Jersey's charter schools are located in the state's poorer, urban school districts, or "Abbott" districts, and exclusively serve students from those communities. A number of other schools are located outside of the Abbott districts but enroll students from these districts. Specifically, of the 50 charter schools operating in…
78 FR 47409 - Meeting of the California Desert District Advisory Council
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-05
... California Desert District Advisory Council SUMMARY: Notice is hereby given, in accordance with Public Laws 92-463 and 94-579, that the California Desert District Advisory Council (DAC) to the Bureau of Land... Desert District Advisory Council, c/o Bureau of Land Management, External Affairs, 22835 Calle San Juan...
Michigan School Privatization Survey 2009
ERIC Educational Resources Information Center
Hohman, James M.; Imhoff, Eric R.
2009-01-01
With Michigan's public school districts facing a decline in per-pupil funding, more districts are contracting out for at least one of the three major school support services--food, custodial and transportation--than ever before. This year's survey of school districts found that 44.6 percent of all Michigan school districts contract out for at…
33 CFR 211.7 - Rights which may be granted by Division and District Engineers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Division and District Engineers. 211.7 Section 211.7 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE REAL ESTATE ACTIVITIES OF THE CORPS OF ENGINEERS IN CONNECTION... be granted by Division and District Engineers. (a) Authority of Division and District Engineers...
ERIC Educational Resources Information Center
Culbertson, Michael J.; Billig, Shelley H.
2016-01-01
Rural districts have long faced challenges in closing achievement gaps between subgroups of students. This brief report describes key decision points and considerations for decision-makers interested in identifying rural districts that have closed academic achievement gaps. Examining practices in these districts may suggest activities associated…
77 FR 75653 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-21
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) will meet as indicated below. DATES: On January 31, 2013, the Twin Falls District RAC members will meet at...
76 FR 48883 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-09
...] Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting AGENCY: Bureau of Land... of the Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Challis, Idaho...
76 FR 26314 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-06
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... (BLM) Twin Falls District Resource Advisory Council (RAC) will meet as indicated below. DATES: May 16, 2011. On May 16, 2011, the Twin Falls District RAC members will meet at the Best Western Sawtooth Inn...
78 FR 19522 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-01
... Public Meeting, Idaho Falls District Resource Advisory Council Meeting AGENCY: Bureau of Land Management... Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Challis, Idaho, April 23-24...
75 FR 27360 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-14
... Public Meeting, Idaho Falls District Resource Advisory Council Meeting AGENCY: Bureau of Land Management... Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Salmon, Idaho on June 22-23...
77 FR 49826 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-17
... Public Meeting, Idaho Falls District Resource Advisory Council Meeting AGENCY: Bureau of Land Management... Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Idaho Falls, Idaho on September...
78 FR 68467 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, ID
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-14
... of Public Meetings, Twin Falls District Resource Advisory Council, ID AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) and..., the Twin Falls District RAC subcommittee members for the Greater sage-grouse will meet at the Twin...
78 FR 56242 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-12
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) will meet as indicated below. DATES: On September 26, 2013, the Twin Falls District RAC members will meet at...
76 FR 30388 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... (BLM) Twin Falls District Resource Advisory Council (RAC) will meet as indicated below. DATES: June 21-22, 2011. On June 21, 2011, the Twin Falls District RAC members will meet at the Idaho Commerce and...
76 FR 79707 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... (BLM) Twin Falls District Resource Advisory Council (RAC) and subcommittee for the Jarbidge Resource Management Plan (RMP) will meet as indicated below. DATES: On January 25, 2012, the Twin Falls District RAC...
78 FR 38071 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-25
... Public Meeting, Idaho Falls District Resource Advisory Council Meeting AGENCY: Bureau of Land Management... Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Pocatello, Idaho, August 27-28...
78 FR 19732 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) will meet as indicated below. DATES: On April 23 2013, the Twin Falls District RAC members will meet at the...
78 FR 17716 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-22
... Public Meeting, Idaho Falls District Resource Advisory Council Meeting AGENCY: Bureau of Land Management... Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Challis, Idaho, April 23-24...
76 FR 28805 - Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
...] Notice of Public Meeting, Idaho Falls District Resource Advisory Council Meeting AGENCY: Bureau of Land... of the Interior, Bureau of Land Management (BLM) Idaho Falls District Resource Advisory Council (RAC), will meet as indicated below. DATES: The Idaho Falls District RAC will meet in Pocatello, Idaho on June...
78 FR 32440 - Notice of Public Meetings, Twin Falls District Resource Advisory Council, Idaho
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-30
... of Public Meetings, Twin Falls District Resource Advisory Council, Idaho AGENCY: Bureau of Land... the Interior, Bureau of Land Management (BLM) Twin Falls District Resource Advisory Council (RAC) will meet as indicated below. DATES: On June 20, 2013, the Twin Falls District RAC members will meet at the...
ERIC Educational Resources Information Center
Desimone, Laura; Porter, Andrew C.; Birman, Beatrice F.; Garet, Michael S.; Yoon, Kwang Suk
2002-01-01
Examined policy mechanisms and processes that districts used to provide high quality inservice professional development to teachers. Data from a national probability sample of professional development coordinators in districts that received federal funding for professional development highlighted specific management and implementation strategies…
Beyond Backpacks and Bus Tokens: Next Steps for a District Homeless Student Initiative
ERIC Educational Resources Information Center
Hallett, Ronald E.; Low, Justin A.; Skrla, Linda
2015-01-01
How policies get translated and enacted by school districts frame how students experience reforms associated with federal law. This qualitative case study of a Northern California school district explores the importance of integrating homeless student initiatives within all aspects of the district functioning. Drawing from the equity framework of…
Reading a District Budget: Reporter Guide
ERIC Educational Resources Information Center
McNeil, Michele
2013-01-01
Every school budget tells a story--about a district's spending plan, its priorities, goals, and financial health. The challenge is to wade through the jargon and numbers to unlock that story. Although budgets can vary significantly from district to district, and state to state, this primer seeks to introduce reporters to the fundamental components…
How to Communicate Your Budget to Nonfinance People
ERIC Educational Resources Information Center
Jones, Linda
2011-01-01
A school district's budget tells the community a story about the district's visions for its students. It is also a planning vehicle that outlines the district's goals and objectives by showing the degree to which its priorities are being supported. Communicating one's district budget to the community--especially to nonfinancial people--in…
A Longitudinal Study of School Districts' Sustained Improvement
ERIC Educational Resources Information Center
Sampson, Pauline M.
2011-01-01
In this longitudinal study of one region in the state of Texas, there was an examination of district leadership and the sustaining of high student achievement for their districts. The results of this study suggest that sustained improvement of student achievement is very difficult. The districts that had sustained improvement had stable district…
Projecting Enrollment in Rural Schools: A Study of Three Vermont School Districts
ERIC Educational Resources Information Center
Grip, Richard S.
2004-01-01
Large numbers of rural districts have experienced sharp declines in enrollment, unlike their suburban counterparts. Accurate enrollment projections are required, whether a district needs to build new schools or consolidate existing ones. For school districts having more than 600 students, a quantitative method such as the Cohort-Survival Ratio…
A Study of Benefits and Selected Salaries of California Community College Districts.
ERIC Educational Resources Information Center
Kern Community Coll. District, Bakersfield, CA.
In an effort to assess the overall fringe benefit programs of community college districts in California and to determine the dollar amounts paid certificated employees, fringe benefit and salary remuneration were calculated for all 70 districts in the state. Study findings included the following: (1) 13 districts offered a "cafeteria…
42 CFR 401.130 - Materials available at social security district offices and branch offices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Materials available at social security district... Confidentiality and Disclosure § 401.130 Materials available at social security district offices and branch... inspection at the social security district offices and branch offices: (1) Compilation of the Social Security...
42 CFR 401.130 - Materials available at social security district offices and branch offices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Materials available at social security district... Confidentiality and Disclosure § 401.130 Materials available at social security district offices and branch... inspection at the social security district offices and branch offices: (1) Compilation of the Social Security...
42 CFR 401.130 - Materials available at social security district offices and branch offices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Materials available at social security district... Confidentiality and Disclosure § 401.130 Materials available at social security district offices and branch... inspection at the social security district offices and branch offices: (1) Compilation of the Social Security...
42 CFR 401.130 - Materials available at social security district offices and branch offices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Materials available at social security district... Confidentiality and Disclosure § 401.130 Materials available at social security district offices and branch... inspection at the social security district offices and branch offices: (1) Compilation of the Social Security...
School District Cash Management. Program Audit.
ERIC Educational Resources Information Center
New York State Legislative Commission on Expenditure Review, Albany.
New York State law permits school districts to invest cash not immediately needed for district operation and also specifies the kinds of investments that may be made in order to ensure the safety and liquidity of public funds. This audit examines cash management and investment practices in New York state's financially independent school districts.…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-07
... By-Laws, Article VIII, Section 8.1 (Establishment of Districts) and Section 8.2 (Composition of..., Article VIII, Section 2(c) (District Committees and District Business Conduct Committees), amended...\\ See FINRA Regulation By-Laws, Article VIII, Section 8.1 (Establishment of Districts) and Section 8.2...
Increasing Poverty: How Do Leaders in One Suburban District Respond?
ERIC Educational Resources Information Center
Spencer, Jennifer Dawn
2014-01-01
This dissertation addresses the question of how suburban school district leaders in one large Midwestern school district respond to increasing student poverty. The purpose of this study was to determine how suburban school district leaders respond to increasing student poverty in their decision making and actions. Data for this study came from one…
Culture: The Missing Link to Learning
ERIC Educational Resources Information Center
Cross, Nathan; Howard, Kathleen; Pearson, Carl
2013-01-01
A high functioning school and district culture is an essential underpinning to all improvement efforts. Yet school and district culture can be difficult to assess. Culture is the cornerstone of all good districts and schools. It is the foundation for all school improvement efforts. As one looks deeper into the culture of a school or district, one…
42 CFR 401.130 - Materials available at social security district offices and branch offices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Materials available at social security district... Confidentiality and Disclosure § 401.130 Materials available at social security district offices and branch... inspection at the social security district offices and branch offices: (1) Compilation of the Social Security...
Teacher Trust in District Administration: A Promising Line of Inquiry
ERIC Educational Resources Information Center
Adams, Curt M.; Miskell, Ryan C.
2016-01-01
Purpose: We set out in this study to establish a foundation for a line of inquiry around teacher trust in district administration by (1) describing the role of trust in capacity building, (2) conceptualizing trust in district administration, (3) developing a scale to measure teacher trust in district administration, and (4) testing the…
Profiles of Merit Pay Provisions in Ohio School Districts
ERIC Educational Resources Information Center
Willis, Chris; Ingle, W. Kyle
2018-01-01
A small number of districts in Ohio from a variety of locales have adopted merit pay provisions. Using Springer's (2009) taxonomy of teacher compensation, we analyzed compensation provisions of these districts. We asked: What are the characteristics of these districts? What criteria are used to determine merit? Who is determining who receives…
33 CFR 211.7 - Rights which may be granted by Division and District Engineers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... WITH CIVIL WORKS PROJECTS Temporary Use by Others of Civil Works Real Estate § 211.7 Rights which may.... Division Engineers, the President of the Mississippi River Commission, and District Engineers of districts... of the Mississippi River Commission in granting leases and District Engineers will administer the...
The Academic Preparation of Idaho Science Teachers Based on School District Size.
ERIC Educational Resources Information Center
Heikkinen, Michael W.
1987-01-01
Certification records of 435 Idaho science teachers analyzed by school district size revealed significant differences: more physiology, earth science, and chemistry I teachers in largest districts had endorsements to teach assigned subjects; more earth science and chemistry I teachers in smallest districts had neither major nor minor in subjects…
Kajankova, Maria; Oswald, Jennifer M; Terranova, Lauren M; Kaplen, Michael V; Ambrose, Anne F; Spielman, Lisa A; Gordon, Wayne A
2017-06-01
By 2014, all states implemented concussion laws that schools must translate into daily practice; yet, limited knowledge exists regarding implementation of these laws. We examined the extent to which concussion management policies and procedure (P&P) documents of New York State school districts comply with the State's Concussion Awareness and Management Act (the Act). We also aimed to identify barriers to compliance. Forty-seven school districts provided P&P documents. We examined compliance with the Act and the relationship between compliance and each district's demographics. Compliance varied across school districts, with higher overall compliance in large city school districts compared to county districts. However, there was low compliance for several critical items. We found no statistically significant relationship between compliance and demographics. School districts need to increase compliance with concussion legislation to ensure the adequate implementation necessary for the law to impact health and educational outcomes. The results provide important information to individuals charged with the responsibility of implementation and ultimately reducing the negative outcomes associated with brain injuries in schools. © 2017, American School Health Association.
Droomers, Mariël; Jongeneel-Grimen, Birthe; Bruggink, Jan-Willem; Kunst, Anton; Stronks, Karien
2016-09-01
To study the general health impact of urban regeneration programmes in deprived Dutch districts. We compared initiatives that focused on the improvement of place with initiatives that mainly invested in people. A quasi-experimental design compared the trend in good perceived general health in the target districts with comparison districts. Generalized general mixed models assessed the rate of change in prevalence of good health per half year during a prolonged period before and after the start of the interventions. Neither the target districts that invested mainly in place nor the ones with interventions focused on people showed trends in general health different than comparison districts (p>0.05). However, only districts with interventions focused on place showed no deterioration in general health during the intervention period. The trend change in these districts differed significantly from the change in the districts that invested mainly in people (p<0.05). Urban regeneration programmes that focus on place may be effective in promoting general health. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Manzella, A.
2017-07-01
Geothermal technologies use renewable energy resources to generate electricity and direct use of heat while producing very low levels of greenhouse-gas (GHG) emissions. Geothermal energy is the thermal energy stored in the underground, including any contained fluid, which is available for extraction and conversion into energy products. Electricity generation, which nowadays produces 73.7 TWh (12.7 GW of capacity) worldwide, usually requires geothermal resources temperatures of over 100 °C. For heating, geothermal resources spanning a wider range of temperatures can be used in applications such as space and district heating (and cooling, with proper technology), spa and swimming pool heating, greenhouse and soil heating, aquaculture pond heating, industrial process heating and snow melting. Produced geothermal heat in the world accounts to 164.6 TWh, with a capacity of 70.9 GW. Geothermal technology, which has focused for decades on extracting naturally heated steam or hot water from natural hydrothermal reservoirs, is developing to more advanced techniques to exploit the heat also where underground fluids are scarce and to use the Earth as a potential energy battery, by storing heat. The success of the research will enable energy recovery and utilization from a much larger fraction of the accessible thermal energy in the Earth's crust.
Clean Power Generation from the Intractable Natural Coalfield Fires: Turn Harm into Benefit.
Shi, Bobo; Su, Hetao; Li, Jinshi; Qi, Haining; Zhou, Fubao; Torero, José L; Chen, Zhongwei
2017-07-13
The coal fires, a global catastrophe for hundreds of years, have been proved extremely difficult to control, and hit almost every coal-bearing area globally. Meanwhile, underground coal fires contain tremendous reservoir of geothermal energy. Approximately one billion tons of coal burns underground annually in the world, which could generate ~1000 GW per annum. A game-changing approach, environmentally sound thermal energy extraction from the intractable natural coalfield fires, is being developed by utilizing the waste energy and reducing the temperature of coalfield fires at the same time. Based on the Seebeck effect of thermoelectric materials, the temperature difference between the heat medium and cooling medium was employed to directly convert thermal energy into clean electrical energy. By the time of December 2016, the power generation from a single borehole at Daquan Lake fire district in Xinjiang has been exceeded 174.6 W. The field trial demonstrates that it is possible to exploit and utilize the waste heat resources in the treated coal fire areas. It promises a significant impact on the structure of global energy generation and can also promote progress in thermoelectric conversion materials, geothermal exploration, underground coal fires control and other energy related areas.
An overview of paleogene molluscan biostratigraphy and paleoecology of the Gulf of Alaska region
Marincovich, L.; McCoy, S.
1984-01-01
Paleogene marine strata in the Gulf of Alaska region occur in three geographic areas and may be characterized by their molluscan faunal composition and paleoecology: a western area consisting of the Alaska Peninsula, Kodiak Island, and adjacent islands; a central area encompassing Prince William Sound; and an eastern area extending from the mouth of the Copper River to Icy Point in the Lituya district. Strata in the western area include the Ghost Rocks, Narrow Cape (in part), Sitkalidak, Stepovak, Belkofski, and Tolstoi Formations; in the central area Paleogene strata are assigned entirely to the Orca Group; Paleogene strata in the eastern area include the Kulthieth and Poul Creek Formations and several coeval units. Environments ranging from marginal marine to bathyal and from subtropical to cool-temperate are inferred for the various molluscan faunas. Sediments range from interbedded coal and marine sands to deep-water turbidites. The known Paleogene molluscan faunas of these three southern Alaskan areas permit recognition of biostratigraphic schemes within each area, preliminary correlations between faunas of the three areas, and more general correlations with faunas of the Pacific Northwest, the Far Eastern U.S.S.R., and northern Japan. ?? 1984.
Frey, Anna K; Saarnio, Karri; Lamberg, Heikki; Mylläri, Fanni; Karjalainen, Panu; Teinilä, Kimmo; Carbone, Samara; Tissari, Jarkko; Niemelä, Ville; Häyrinen, Anna; Rautiainen, Jani; Kytömäki, Jorma; Artaxo, Paulo; Virkkula, Aki; Pirjola, Liisa; Rönkkö, Topi; Keskinen, Jorma; Jokiniemi, Jorma; Hillamo, Risto
2014-01-01
Particle emissions affect radiative forcing in the atmosphere. Therefore, it is essential to know the physical and chemical characteristics of them. This work studied the chemical, physical, and optical characteristics of particle emissions from small-scale wood combustion, coal combustion of a heating and power plant, as well as heavy and light fuel oil combustion at a district heating station. Fine particle (PM1) emissions were the highest in wood combustion with a high fraction of absorbing material. The emissions were lowest from coal combustion mostly because of efficient cleaning techniques used at the power plant. The chemical composition of aerosols from coal and oil combustion included mostly ions and trace elements with a rather low fraction of absorbing material. The single scattering albedo and aerosol forcing efficiency showed that primary particles emitted from wood combustion and some cases of oil combustion would have a clear climate warming effect even over dark earth surfaces. Instead, coal combustion particle emissions had a cooling effect. Secondary processes in the atmosphere will further change the radiative properties of these emissions but are not considered in this study.
Fertility transition and adverse child sex ratio in districts of India.
Mohanty, Sanjay K; Rajbhar, Mamta
2014-11-01
Demographic research in India over the last two decades has focused extensively on fertility change and gender bias at the micro-level, and less has been done at the district level. Using data from the Census of India 1991-2011 and other sources, this paper shows the broad pattern of fertility transition and trends in the child sex ratio in India, and examines the determinants of the child sex ratio at the district level. During 1991-2011, while the Total Fertility Rate (TFR) declined by 1.2 children per woman, the child sex ratio fell by 30 points in the districts of India. However, the reduction in fertility was slower in the high-fertility compared with the low-fertility districts. The gender differential in under-five mortality increased in many districts of India over the study period. The decline in the child sex ratio was higher in the transitional compared with the low-fertility districts. The transitional districts are at higher risk of a low child sex ratio due to an increased gender differential in mortality and increase in the practice of sex-selective abortions. The sex ratio at birth and gender differential in mortality explains one-third of the variation, while region alone explains a quarter of the variation in the child sex ratio in the districts of India.
Cost analysis and efficiency of sub-district health facilities in two districts in Ghana.
Aboagye, Anthony Q Q; Degboe, Arnold N K
2011-01-01
To establish the full costs borne by sub-district health facilities in providing services, we analysed the costs and revenues of 10 sub-district health facilities located in two districts in Ghana. The full costs were obtained by considering staff costs, cost of utilities, cost of using health facility equipment, cost of non-drug consumables, equipment maintenance expenses, amounts spent on training, community information sessions and other outreach activities as well as all other costs incurred in running the facilities. We found that (i) a large proportion of sub-district health facility costs is made up of staff salaries; (ii) at all facilities, internally generated funds (IGFs) are substantially lower than costs incurred in running the facilities; (iii) average IGF is several times higher in one district than the other; (iv) wide variations exist in efficiency indicators and (v) there is some evidence that sub-district health facilities may not necessarily be financially more efficient than hospitals in using financial resources. We suggest that the study should be replicated in other districts; but in the mean time, the health authorities should take note of the conclusions and recommendations of this study. Efforts should also be made to improve record keeping at these facilities. Copyright © 2010 John Wiley & Sons, Ltd.
Bonenberger, Marc; Aikins, Moses; Akweongo, Patricia; Bosch-Capblanch, Xavier; Wyss, Kaspar
2015-01-01
Ineffective district health management potentially impacts on health system performance and service delivery. However, little is known about district health managing practices and time allocation in resource-constrained health systems. Therefore, a time use study was conducted in order to understand current time use practices of district health managers in Ghana. All 21 district health managers working in three districts of the Eastern Region were included in the study and followed for a period of three months. Daily retrospective interviews about their time use were conducted, covering 1182 person-days of observation. Total time use of the sample population was assessed as well as time use stratified by managerial position. Differences of time use over time were also evaluated. District health managers used most of their working time for data management (16.6%), attending workshops (12.3%), financial management (8.7%), training of staff (7.1%), drug and supply management (5.0%), and travelling (9.6%). The study found significant variations of time use across the managerial cadres as well as high weekly variations of time use impulsed mainly by a national vertical program. District health managers in Ghana use substantial amounts of their working time in only few activities and vertical programs greatly influence their time use. Our findings suggest that efficiency gains are possible for district health managers. However, these are unlikely to be achieved without improvements within the general health system, as inefficiencies seem to be largely caused by external factors.
Theileria annulata seroprevalence among different cattle breeds in Rajshahi Division, Bangladesh.
Ali, Md Wajed; Alauddin, Md; Azad, Md Thoufic Anam; Hasan, Md Ariful; Appiah-Kwarteng, Cornelia; Takasu, Masaki; Baba, Minami; Kitoh, Katsuya; Rahman, Moizur; Takashima, Yasuhiro
2016-11-01
An epidemiological survey of Theileria annulata infection was undertaken in a cattle population in Rajshahi Division, Bangladesh. The local cattle breeds from the area (North Bengal Gray and Deshi) and crosses between the local breeds and Holstein cattle were predominantly screened. In total, 192 cattle serum samples were collected in two areas of Rajshahi Division, the Rajshahi District (n=147) and Natore District (n=45). The samples were screened with an enzyme-linked immunosorbent assay using T. annulata surface protein (TaSP) as the antigen. The seroprevalence was 80.0% (36/45) in Natore and 20.4% (30/147) in Rajshahi. A logistic regression analysis showed that the sampling location was significantly associated with seropositivity, whereas age, sex and breed were not. Although the logistic regression analysis did not show a linear dependence on age, we considered age-specific seroprevalence separately in the two districts. Seroprevalence did not differ significantly among age categories in the Natore District. In contrast, all the cattle <1 year old in the Rajshahi District were seronegative (11/11). Seroprevalence in the 1- and 2-year-old cattle was significantly lower in the Rajshahi District than in the Natore District. In the older age categories (3, 4 and >5 years), seroprevalence did not differ significantly between the Natore and Rajshahi Districts. These results suggest that the cattle in the Rajshahi District were sporadically exposed to T. annulata, whereas most cattle in the Natore District became infected during an early phase of life.
Theileria annulata seroprevalence among different cattle breeds in Rajshahi Division, Bangladesh
ALI, Md. Wajed; ALAUDDIN, Md.; AZAD, Md. Thoufic Anam; HASAN, Md. Ariful; APPIAH-KWARTENG, Cornelia; TAKASU, Masaki; BABA, Minami; KITOH, Katsuya; RAHMAN, Moizur; TAKASHIMA, Yasuhiro
2016-01-01
An epidemiological survey of Theileria annulata infection was undertaken in a cattle population in Rajshahi Division, Bangladesh. The local cattle breeds from the area (North Bengal Gray and Deshi) and crosses between the local breeds and Holstein cattle were predominantly screened. In total, 192 cattle serum samples were collected in two areas of Rajshahi Division, the Rajshahi District (n=147) and Natore District (n=45). The samples were screened with an enzyme-linked immunosorbent assay using T. annulata surface protein (TaSP) as the antigen. The seroprevalence was 80.0% (36/45) in Natore and 20.4% (30/147) in Rajshahi. A logistic regression analysis showed that the sampling location was significantly associated with seropositivity, whereas age, sex and breed were not. Although the logistic regression analysis did not show a linear dependence on age, we considered age-specific seroprevalence separately in the two districts. Seroprevalence did not differ significantly among age categories in the Natore District. In contrast, all the cattle <1 year old in the Rajshahi District were seronegative (11/11). Seroprevalence in the 1- and 2-year-old cattle was significantly lower in the Rajshahi District than in the Natore District. In the older age categories (3, 4 and >5 years), seroprevalence did not differ significantly between the Natore and Rajshahi Districts. These results suggest that the cattle in the Rajshahi District were sporadically exposed to T. annulata, whereas most cattle in the Natore District became infected during an early phase of life. PMID:27396398
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, Phillip N.
2014-11-01
Snohomish County Public Utilities District (the District or Snohomish PUD) provides electricity to about 325,000 customers in Snohomish County, Washington. The District has an incentive programs to encourage commercial customers to improve energy efficiency: the District partially reimburses the cost of approved retrofits if they provide a level of energy performance improvement that is specified by contract. In 2013 the District contracted with Lawrence Berkeley National Laboratory to provide a third-party review of the Monitoring and Verification (M&V) practices the District uses to evaluate whether companies are meeting their contractual obligations. This work helps LBNL understand the challenges faced bymore » real-world practitioners of M&V of energy savings, and builds on a body of related work such as Price et al. (2013). The District selected a typical project for which they had already performed an evaluation. The present report includes the District's original evaluation as well as LBNL's review of their approach. The review is based on the document itself; on investigation of the load data and outdoor air temperature data from the building evaluated in the document; and on phone discussions with Bill Harris of the Snohomish County Public Utilities District. We will call the building studied in the document the subject building, the original Snohomish PUD report will be referred to as the Evaluation, and this discussion by LBNL is called the Review.« less
NASA Astrophysics Data System (ADS)
Jaxa-Rozen, Marc; Bloemendal, Martin; Rostampour, Vahab
2017-04-01
In the context of increasingly strict requirements for building energy efficiency, Aquifer Thermal Energy Storage (ATES) systems have emerged as an effective means to reduce energy demand for space heating and cooling in larger buildings. In the Netherlands, over 2000 systems are currently active, which has already raised issues with spatial planning in some areas; current planning schemes may lack the flexibility to properly address variations in ATES operation, which are driven by uncertainties across a broad range of time scales - from daily changes in building energy demand, to decadal trends for climate or groundwater conditions. This work is therefore part of a broader research effort on ATES Smart Grids (ATES-SG), which has focused on more adaptive methods for ATES management and control. In particular, improved control schemes which allow for coordination between neighboring ATES systems may offer more robust performance under uncertainty (Rostampour & Keviczky, 2016). The case studies for the ATES-SG project have so far focused on idealized cases, and on a historical simulation of ATES development in the city center of Utrecht. This poster will present an additional case study for the city center of Amsterdam, which poses several geohydrological challenges for ATES: for instance, variable density flow due to salinity gradients in the local aquifer, and varying depths for ATES systems due to the thickness of the aquifer. To study the effect of these conditions, this case uses an existing 15-layer geohydrological model of the Amsterdam region, cropped to an area of 4500m x 2500m around the Amsterdam Zuidas district. This rapidly developing business district is one of the densest areas of ATES use in Amsterdam, with 32 well doublets and 53 monowells currently registered. The geohydrological model is integrated with GIS data to accurately represent ATES spatial planning; simulated well flows are provided by a model predictive control component. This model is then simulated for two cases: a baseline decoupled configuration without coordination, and a case in which a subset of adjacent ATES systems is managed centrally to avoid overlaps between stored thermal volumes. Given that the thickness of the local aquifer offers significant potential for further ATES adoption in the area, such a coordinated approach could help maximize the benefits of future ATES development. References Rostampour, V., & Keviczky, T. (2016). Probabilistic Energy Management for Building Climate Comfort in Smart Thermal Grids with Seasonal Storage Systems. Submitted to IFAC World Congress 2017. Available at https://arxiv.org/abs/1611.03206
[Living conditions and pattern of acute poisonings in Oslo].
Kolvik, Hallgeir Mæsel; Heyerdahl, Fridtjof; Bjørnaas, Mari Asphjell; Hovda, Knut Erik; Jacobsen, Dag; Ekeberg, Øivind
2011-08-09
Hospitalized patients with acute poisoning come from all classes of society. The relationship between living conditions and pattern of poisoning is, however, unclear. The aim of this study was to examine the connection between living conditions in Oslo and the pattern of acute poisonings, measured by incidence, main toxic agents and intention. A one-year multi-centre study with prospective inclusion of all patients ≥ 18 years of age with a registered address in Oslo admitted to an Oslo hospital with acute poisoning from 1 April 2003 through 31 March 2004. The 15 city districts were grouped into three, according to the official living conditions index in Oslo: city district group 1 (best living conditions), city district group 2 (average living conditions) and city district group 3 (most difficult living conditions). Of a total of 947 patients admitted with acute poisoning as their main diagnosis in the study period, 691 were included in the study, 660 of whom had self-inflicted poisoning. In city district group 3, the annual incidence of acute poisonings was 2.14 per 1000 inhabitants, significantly higher than city district group 2, with 1.50 (p < 0.001), and city district group 1, with 1.36 (p < 0.001). Measured as intention assessed by the treating physician, suicidal and drug related poisonings and those induced by a "cry for help" were more common in city district group 3 (0.74, 0.59 and 0.74 per 1000 inhabitants, respectively) than in city district group 2 (0.62, 0.40 and 0.41, respectively) and city district group 1 (0.52, 0.32 and 0.45, respectively). The main toxic agents were predominantly benzodiazepines (20 %), ethanol (18 %) and paracetamol (12 %). There were no statistically significant differences in the distribution of main toxic agents between the city district groups. The findings show a social gradient, with the highest incidence of poisonings in the city district group with the most difficult living conditions.
NASA Astrophysics Data System (ADS)
Zhang, J.; Zhang, J.; Huo, X.; Zheng, W.; Zheng, X.; Zhang, M.
2017-08-01
Historic districts are a special type of cultural heritage, as living cultural heritage, the utilization and development of historical districts is an inevitable issue. How to accurately position the protection and utilization of districts and achieve its healthy and sustainable development is the key work in the protection of districts. In this paper, the Internet data including Tencent's location big data are employed to study some Chinese historic and cultural streets, establish protection and development index system for historic and cultural streets, carry out in-depth study of ten core indicators, and sum up the positioning and development direction for the protection and use of districts. Historic district, as a special type of cultural heritage, is the birthplace and supporting zone of urban context, and also the place for the daily life of the general public. It boasts profound historic and humanistic background and the characteristics of a living form. As the living cultural heritage, its use and development are necessary, and attention shall also be paid to static protection and dynamic comprehensive management. But judging from the current practice, protection and use of historic districts face a host of challenges. Some districts are devoid of popularity and vitality and become cold galleries. Some districts suffer excessive development for tourism and commercialism, and lose its "original" cultural characteristics. In addition, throngs of tourists exert a negative impact on the life of the local people and the protection of immovable cultural relics. Disorderly business format and increasingly similar landscape go against the presentation of local characteristics. We should regard historic district as a dynamic urban heritage, and achieve dynamic development and protection in accordance with its inherent development laws and the principle of "step by step" through the "organic update" mode, with emphasis on the continuous comprehensive management of material space environment and cultural society. Therefore, how to make accurate positioning of the protection and utilization of districts and achieve its healthy and sustainable development is the key work in the protection of districts.
Joseph, Chakupewa; Maluka, Stephen Oswald
2016-09-26
In early 1990s, Tanzania like other African countries, adopted health sector reform (HSR). The most strongly held centralisation system that informed the nature of services provision including health was, thus, disintegrated giving rise to decentralisation system. It was within the realm of HSR process, user fees were introduced in the health sector. Along with user fees, various types of health insurances, including the Community Health Fund (CHF), were introduced. While the country's level of enrolment in the CHF is low, there are marked variations among districts. This paper highlights the role of decentralised health management and leadership practices in the uptake of the CHF in Tanzania. A comparative exploratory case study of high and low performing districts was carried out. In-depth interviews were conducted with the members of the Council Health Service Board (CHSB), Council Health Management Team (CHMT), Health Facility Committees (HFCs), in-charges of health facilities, healthcare providers, and Community Development Officers (CDOs). Minutes of the meetings of the committees and district annual health plans and district annual implementation reports were also used to verify and triangulate the data. Thematic analysis was adopted to analyse the collected data. We employed both inductive and deductive (mixed coding) to arrive to the themes. There were no differences in the level of education and experience of the district health managers in the two study districts. Almost all district health managers responsible for the management of the CHF had attended some training on management and leadership. However, there were variations in the personal initiatives of the top-district health leaders, particularly the district health managers, the council health services board and local government officials. Similarly, there were differences in the supervision mechanisms, and incentives available for the health providers, HFCs and board members in the two study districts. This paper adds to the stock of knowledge on CHFs functioning in Tanzania. By comparing the best practices with the worst practices, the paper contributes valuable insights on how CHF can be scaled up and maintained. The study clearly indicates that the performance of the community-based health financing largely depends on the personal initiatives of the top-district health leaders, particularly the district health managers and local government officials. This implies that the regional health management team (RHMT) and the Ministry of Health and Social Welfare (MoHSW) should strengthen supportive supervision mechanisms to the district health managers and health facilities. More important, there is need for the MoHSW to provide opportunities for the well performing districts to share good practices to other districts in order to increase uptake of the community-based health insurance.
Revisiting the Cooling Flow Problem in Galaxies, Groups, and Clusters of Galaxies
NASA Astrophysics Data System (ADS)
McDonald, M.; Gaspari, M.; McNamara, B. R.; Tremblay, G. R.
2018-05-01
We present a study of 107 galaxies, groups, and clusters spanning ∼3 orders of magnitude in mass, ∼5 orders of magnitude in central galaxy star formation rate (SFR), ∼4 orders of magnitude in the classical cooling rate ({\\dot{M}}cool}\\equiv {M}gas}(r< {r}cool})/{t}cool}) of the intracluster medium (ICM), and ∼5 orders of magnitude in the central black hole accretion rate. For each system in this sample, we measure the ICM cooling rate, {\\dot{M}}cool}, using archival Chandra X-ray data and acquire the SFR and systematic uncertainty in the SFR by combining over 330 estimates from dozens of literature sources. With these data, we estimate the efficiency with which the ICM cools and forms stars, finding {ε }cool}\\equiv {SFR}/{\\dot{M}}cool}=1.4 % +/- 0.4% for systems with {\\dot{M}}cool}> 30 M ⊙ yr‑1. For these systems, we measure a slope in the SFR–{\\dot{M}}cool} relation greater than unity, suggesting that the systems with the strongest cool cores are also cooling more efficiently. We propose that this may be related to, on average, higher black hole accretion rates in the strongest cool cores, which could influence the total amount (saturating near the Eddington rate) and dominant mode (mechanical versus radiative) of feedback. For systems with {\\dot{M}}cool}< 30 M ⊙ yr‑1, we find that the SFR and {\\dot{M}}cool} are uncorrelated and show that this is consistent with star formation being fueled at a low (but dominant) level by recycled ISM gas in these systems. We find an intrinsic log-normal scatter in SFR at a fixed {\\dot{M}}cool} of 0.52 ± 0.06 dex (1σ rms), suggesting that cooling is tightly self-regulated over very long timescales but can vary dramatically on short timescales. There is weak evidence that this scatter may be related to the feedback mechanism, with the scatter being minimized (∼0.4 dex) for systems for which the mechanical feedback power is within a factor of two of the cooling luminosity.
Experimental evaluation of cooling efficiency of the high performance cooling device
NASA Astrophysics Data System (ADS)
Nemec, Patrik; Malcho, Milan
2016-06-01
This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.
Francy, D.S.; Jones, A.L.; Myers, Donna N.; Rowe, G.L.; Eberle, Michael; Sarver, K.M.
1998-01-01
The U.S. Geological Survey (USGS), Water Resources Division (WRD), requires that quality-assurance/quality-control (QA/QC) activities be included in any sampling and analysis program. Operational QA/QC procedures address local needs while incorporating national policies. Therefore, specific technical policies were established for all activities associated with water-quality project being done by the Ohio District. The policies described in this report provide Ohio District personnel, cooperating agencies, and others with a reference manual on QA/QC procedures that are followed in collecitng and analyzing water-quality samples and reporting water-quality information in the Ohio District. The project chief, project support staff, District Water-Quality Specialist, and District Laboratory Coordinator are all involved in planning and implementing QA/QC activities at the district level. The District Chief and other district-level managers provide oversight, and the Regional Water-Quality Specialist, Office of Water Quality (USGS headquarters), and the Branch of Quality Systems within the Office of Water Quality create national QA/QC polices and provide assistance to District personnel. In the literature, the quality of all measurement data is expressed in terms of precision, variability, bias, accuracy, completeness, representativeness, and comparability. In the Ohio District, bias and variability will be used to describe quality-control data generated from samples in the field and laboratory. Each project chief must plan for implementation and financing of QA/QC activities necessary to achieve data-quality objectives. At least 15 percent of the total project effort must be directed toward QA/QC activities. Of this total, 5-10 percent will be used for collection and analysis of quality-control samples. This is an absolute minimum, and more may be required based on project objectives. Proper techniques must be followed in the collection and processing of surface-water, ground-water, biological, precipitation, bed-sediment, bedload, suspended-sediment, and solid-phase samples. These techniques are briefly described in this report and are extensively documented. The reference documents listed in this report will be kept by the District librarian and District Water-Quality Specialist and updated regularly so that they are available to all District staff. Proper handling and documentation before, during, and after field activities are essential to ensure the integrity of the sample and to correct erroneous reporting of data results. Field sites are to be properly identified and entered into the data base before field data-collection activities begin. During field activities, field notes are to be completed and sample bottles appropriately labeled a nd stored. After field activities, all paperwork is to be completed promptly and samples transferred to the laboratory within allowable holding times. All equipment used by District personnel for the collection and processing of water-quality samples is to be properly operated, maintained, and calibrated by project personnel. This includes equipment for onsite measurement of water-quality characteristics (temperature, specific conductance, pH, dissolved oxygen, alkalinity, acidity, and turbidity) and equipment and instruments used for biological sampling. The District Water-Quality Specialist and District Laboratory Coordinator are responsible for preventive maintenance and calibration of equipment in the Ohio District laboratory. The USGS National Water Quality Laboratory in Arvada, Colo., is the primary source of analytical services for most project work done by the Ohio District. Analyses done at the Ohio District laboratory are usually those that must be completed within a few hours of sample collection. Contract laboratories or other USGS laboratories are sometimes used instead of the NWQL or the Ohio District laboratory. When a contract laboratory is used, the projec