Sample records for district heating net

  1. A thermodynamic analysis of a novel bidirectional district heating and cooling network

    DOE PAGES

    Zarin Pass, R.; Wetter, M.; Piette, M. A.

    2017-11-29

    In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on themore » thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.« less

  2. A thermodynamic analysis of a novel bidirectional district heating and cooling network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zarin Pass, R.; Wetter, M.; Piette, M. A.

    In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on themore » thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merrick, Dale E

    A small community in Northern California is attempting to use a local geothermal resource to generate electrical power and cascade residual energy to an existing geothermal district heating system, greenhouse, and future fish farm and subsequent reinjection into the geothermal aquifer, creating a net-zero energy community, not including transportation.

  4. Estimating the potential for industrial waste heat reutilization in urban district energy systems: method development and implementation in two Chinese provinces

    NASA Astrophysics Data System (ADS)

    Tong, Kangkang; Fang, Andrew; Yu, Huajun; Li, Yang; Shi, Lei; Wang, Yangjun; Wang, Shuxiao; Ramaswami, Anu

    2017-12-01

    Utilizing low-grade waste heat from industries to heat and cool homes and businesses through fourth generation district energy systems (DES) is a novel strategy to reduce energy use. This paper develops a generalizable methodology to estimate the energy saving potential for heating/cooling in 20 cities in two Chinese provinces, representing cold winter and hot summer regions respectively. We also conduct a life-cycle analysis of the new infrastructure required for energy exchange in DES. Results show that heating and cooling energy use reduction from this waste heat exchange strategy varies widely based on the mix of industrial, residential and commercial activities, and climate conditions in cities. Low-grade heat is found to be the dominant component of waste heat released by industries, which can be reused for both district heating and cooling in fourth generation DES, yielding energy use reductions from 12%-91% (average of 58%) for heating and 24%-100% (average of 73%) for cooling energy use in the different cities based on annual exchange potential. Incorporating seasonality and multiple energy exchange pathways resulted in energy savings reductions from 0%-87%. The life-cycle impact of added infrastructure was small (<3% for heating) and 1.9% ~ 6.5% (cooling) of the carbon emissions from fuel use in current heating or cooling systems, indicating net carbon savings. This generalizable approach to delineate waste heat potential can help determine suitable cities for the widespread application of industrial waste heat re-utilization.

  5. Projected configuration of a coal-fired district heating source on the basis of comparative technical-economical optimization analysis

    NASA Astrophysics Data System (ADS)

    Tańczuk, Mariusz; Radziewicz, Wojciech; Olszewski, Eligiusz; Skorek, Janusz

    2017-10-01

    District heating technologies should be efficient, effective and environmentally friendly. The majority of the communal heating systems in Poland produce district hot water in coal-fired boilers. A large number of them are considerably worn out, low-efficient in the summer time and will not comply with forthcoming regulations. One of the possible solution for such plants is repowering with new CHP systems or new boilers fuelled with fuels alternative to coal. Optimisation analysis of the target configuration of municipal heat generating plant is analysed in the paper. The work concerns repowering the existing conventional heat generating plant according to eight different scenarios of the plant configuration meeting technical and environmental requirements forecasted for the year of 2035. The maximum demand for heat of the system supplied by the plant is 185 MW. Taking into account different technical configurations on one side, and different energy and fuel prices on the other side, the comparative cost-benefits analysis of the assumed scenarios has been made. The basic economical index NPV (net present value) has been derived for each analysed scenario and the results have been compared and discussed. It was also claimed that the scenario with CHP based on ICE engines is optimal.

  6. Analysis of a combined heating and cooling system model under different operating strategies

    NASA Astrophysics Data System (ADS)

    Dzierzgowski, Mieczysław; Zwierzchowski, Ryszard

    2017-11-01

    The paper presents an analysis of a combined heating and cooling system model under different operating strategies. Cooling demand for air conditioning purposes has grown steadily in Poland since the early 1990s. The main clients are large office buildings and shopping malls in downtown locations. Increased demand for heat in the summer would mitigate a number of problems regarding District Heating System (DHS) operation at minimum power, affecting the average annual price of heat (in summertime the share of costs related to transport losses is a strong cost factor). In the paper, computer simulations were performed for different supply network water temperature, assuming as input, real changes in the parameters of the DHS (heat demand, flow rates, etc.). On the basis of calculations and taking into account investment costs of the Absorption Refrigeration System (ARS) and the Thermal Energy Storage (TES) system, an optimal capacity of the TES system was proposed to ensure smooth and efficient operation of the District Heating Plant (DHP). Application of ARS with the TES system in the DHS in question increases net profit by 19.4%, reducing the cooling price for consumers by 40%.

  7. Heat-pump-centered integrated community energy systems: System development summary

    NASA Astrophysics Data System (ADS)

    Calm, J. M.

    1980-02-01

    An introduction to district heating systems employing heat pumps to enable use of low temperature energy sources is presented. These systems operate as thermal utilities to provide space heating and may also supply space cooling, service water heating, and other thermal services. Otherwise wasted heat from industrial and commercial processes, natural sources including solar and geothermal heat, and heat stored on an annual cycle from summer cooling may be effectively utilized by the systems described. More than one quarter of the energy consumed in the United States is used to heat and cool buildings and to heat service water. Natural gas and oil provide approximately 83% of this energy. The systems described show potential to reduce net energy consumption for these services by 20 to 50% and to allow fuel substitution with less scarce resources not practical in smaller, individual building systems. Seven studies performed for the system development phase are summarized.

  8. Effects of heat recovery for district heating on waste incineration health impact: a simulation study in Northern Italy.

    PubMed

    Cordioli, Michele; Vincenzi, Simone; De Leo, Giulio A

    2013-02-01

    The construction of waste incinerators in populated areas always causes substantial public concern. Since the heat from waste combustion can be recovered to power district heating networks and allows for the switch-off of domestic boilers in urbanized areas, predictive models for health assessment should also take into account the potential benefits of abating an important source of diffuse emission. In this work, we simulated the dispersion of atmospheric pollutants from a waste incinerator under construction in Parma (Italy) into different environmental compartments and estimated the potential health effect of both criteria- (PM(10)) and micro-pollutants (PCDD/F, PAH, Cd, Hg). We analyzed two emission scenarios, one considering only the new incinerator, and the other accounting for the potential decrease in pollutant concentrations due to the activation of a district heating network. We estimated the effect of uncertainty in parameter estimation on health risk through Monte Carlo simulations. In addition, we analyzed the robustness of health risk to alternative assumptions on: a) the geographical origins of the potentially contaminated food, and b) the dietary habits of the exposed population. Our analysis showed that under the specific set of assumptions and emission scenarios explored in the present work: (i) the proposed waste incinerator plant appears to cause negligible harm to the resident population; (ii) despite the net increase in PM(10) mass balance, ground-level concentration of fine particulate matter may be curbed by the activation of an extensive district heating system powered through waste combustion heat recovery and the concurrent switch-off of domestic/industrial heating boilers. In addition, our study showed that the health risk caused by waste incineration emissions is sensitive to assumptions about the typical diet of the resident population, and the geographical origins of food production. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Winter fuels report, week ending November 12, 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-11-18

    The Winter Fuels Report is intended to provide concise, timely information to the industry, the press, policymakers, consumers, analysts, and State and local governments on the following topics: Distillate fuel oil net production, imports and stocks on a US level and for all Petroleum Administration for Defense Districts (PADD) and product supplied on a US level; propane net production, imports and stocks on a US level and for PADD`s I, II, and III; natural gas supply and disposition and underground storage for the US and consumption for all PADD`S; as well as selected National average prices; residential and wholesale pricingmore » data for heating oil and propane for those States participating in the joint Energy Information Administration (EIA)/State Heating Oil and Propane Program; crude oil and petroleum price comparisons for the US and selected cities; and a 6--10 Day, 30-Day, and 90-Day outlook for temperature and precipitation and US total heating degree-days by city.« less

  10. Evaluating the electronic tuberculosis register surveillance system in Eden District, Western Cape, South Africa, 2015.

    PubMed

    Mlotshwa, Mandla; Smit, Sandra; Williams, Seymour; Reddy, Carl; Medina-Marino, Andrew

    2017-01-01

    Tuberculosis (TB) surveillance data are crucial to the effectiveness of National TB Control Programs. In South Africa, few surveillance system evaluations have been undertaken to provide a rigorous assessment of the platform from which the national and district health systems draws data to inform programs and policies. Evaluate the attributes of Eden District's TB surveillance system, Western Cape Province, South Africa. Data quality, sensitivity and positive predictive value were assessed using secondary data from 40,033 TB cases entered in Eden District's ETR.Net from 2007 to 2013, and 79 purposively selected TB Blue Cards (TBCs), a medical patient file and source document for data entered into ETR.Net. Simplicity, flexibility, acceptability, stability and usefulness of the ETR.Net were assessed qualitatively through interviews with TB nurses, information health officers, sub-district and district coordinators involved in the TB surveillance. TB surveillance system stakeholders report that Eden District's ETR.Net system was simple, acceptable, flexible and stable, and achieves its objective of informing TB control program, policies and activities. Data were less complete in the ETR.Net (66-100%) than in the TBCs (76-100%), and concordant for most variables except pre-treatment smear results, antiretroviral therapy (ART) and treatment outcome. The sensitivity of recorded variables in ETR.Net was 98% for gender, 97% for patient category, 93% for ART, 92% for treatment outcome and 90% for pre-treatment smear grading. Our results reveal that the system provides useful information to guide TB control program activities in Eden District. However, urgent attention is needed to address gaps in clinical recording on the TBC and data capturing into the ETR.Net system. We recommend continuous training and support of TB personnel involved with TB care, management and surveillance on TB data recording into the TBCs and ETR.Net as well as the implementation of a well-structured quality control and assurance system.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunsberger, Randolph; Tomberlin, Gregg; Gaul, Chris

    As part of the Army Net-Zero Energy Installation program, the Fort Carson Army Base requested that NREL evaluate the feasibility of adding a biomass boiler to the district heating system served by Building 1860. We have also developed an Excel-spreadsheet-based decision support tool--specific to the historic loads served by Building 1860--with which users can perform what-if analysis on gas costs, biomass costs, and other parameters. For economic reasons, we do not recommend adding a biomass system at this time.

  12. Assessment on the ownership and use of mosquito nets in Mozambique

    PubMed Central

    Arroz, Jorge Alexandre Harrison; Chirrute, Francisco; Mendis, Chandana; e, Marta Honesta Chande; Kollhoff, Veronique

    2016-01-01

    ABSTRACT OBJECTIVE To assess the ownership and use of mosquito nets in 2014, in Mozambique. METHODS This observational and cross-sectional study assessed, in February and March 2015, 69 districts (nine of 11 provinces of Mozambique) that have benefited from the mass distribution of mosquito nets. The Lot Quality Assurance Sampling methodology was used. Each locality was denominated supervision area. The Lot Quality Assurance Sampling opts for a minimum of 19 households (in this case, we decided for a minimum of 100 households per district) from each supervision area to assess an indicator (in this case, two indicators were assessed: ownership and use of mosquito nets). Two questions guided the research: a) received a mosquito net; b) used a mosquito net the night before. RESULTS A total of 6,725 households were assessed. Eighty three percent of them had received mosquito nets in the campaign. Of the 6,232 respondents, 82.0% said they used mosquito nets the night before. The districts of the provinces with low coverage of ownership and use were Tete (69.5% and 60.0%, respectively), Zambezia (79.0% and 60.0%, respectively), and Gaza (81.6% and 70.7%, respectively). The largest coverage of ownership and use were observed in the districts of Nampula (96.7% and 93.8%, respectively) and Niassa (86.0% and 85.4% respectively). CONCLUSIONS In the districts assessed, the progression of ownership and use of mosquito nets is satisfactory. Nampula and Niassa are the only provinces where ownership and use are at desired levels. PMID:28099655

  13. German central solar heating plants with seasonal heat storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, D.; Marx, R.; Nussbicker-Lux, J.

    2010-04-15

    Central solar heating plants contribute to the reduction of CO{sub 2}-emissions and global warming. The combination of central solar heating plants with seasonal heat storage enables high solar fractions of 50% and more. Several pilot central solar heating plants with seasonal heat storage (CSHPSS) built in Germany since 1996 have proven the appropriate operation of these systems and confirmed the high solar fractions. Four different types of seasonal thermal energy stores have been developed, tested and monitored under realistic operation conditions: Hot-water thermal energy store (e.g. in Friedrichshafen), gravel-water thermal energy store (e.g. in Steinfurt-Borghorst), borehole thermal energy store (inmore » Neckarsulm) and aquifer thermal energy store (in Rostock). In this paper, measured heat balances of several German CSHPSS are presented. The different types of thermal energy stores and the affiliated central solar heating plants and district heating systems are described. Their operational characteristics are compared using measured data gained from an extensive monitoring program. Thus long-term operational experiences such as the influence of net return temperatures are shown. (author)« less

  14. The impact of a hybrid social marketing intervention on inequities in access, ownership and use of insecticide-treated nets.

    PubMed

    Agha, Sohail; Van Rossem, Ronan; Stallworthy, Guy; Kusanthan, Thankian

    2007-01-29

    An ITN intervention was initiated in three predominantly rural districts of Eastern Province, Zambia, that lacked commercial distribution and communication infrastructures. Social marketing techniques were used for product and message development. Public sector clinics and village-based volunteers promoted and distributed subsidized ITNs priced at 2.5 dollars per net. A study was conducted to assess the effects of the intervention on inequities in knowledge, access, ownership and use of ITNs. A post-test only quasi-experimental study design was used to compare intervention and comparison districts. A total of 2,986 respondents were interviewed. Survey respondents were grouped into four socio-economic (SES) categories: low, medium-low, medium and high. Knowledge, access, ownership and use indicators are compared. Concentration index scores are calculated. Interactions between intervention status and SES help determine how different SES groups benefited from the intervention. Although overall use of nets remained relatively low, post-test data show that knowledge, access, ownership and use of mosquito nets was higher in intervention districts. A decline in SES inequity in access to nets occurred in intervention districts, resulting from a disproportionately greater increase in access among the low SES group. Declines in SES inequities in net ownership and use of nets were associated with the intervention. The largest increases in net ownership and use occurred among medium and high SES categories. Increasing access to nets among the poorest respondents in rural areas may not lead to increases in net use unless the price of nets is no longer a barrier to their purchase.

  15. Prioritizing health system and disease burden factors: an evaluation of the net benefit of transferring health technology interventions to different districts in Zimbabwe.

    PubMed

    Shamu, Shepherd; Rusakaniko, Simbarashe; Hongoro, Charles

    2016-01-01

    Health-care technologies (HCTs) play an important role in any country's health-care system. Zimbabwe's health-care system uses a lot of HCTs developed in other countries. However, a number of local factors have affected the absorption and use of these technologies. We therefore set out to test the hypothesis that the net benefit regression framework (NBRF) could be a helpful benefit testing model that enables assessment of intra-national variables in HCT transfer. We used an NBRF model to assess the benefits of transferring cost-effective technologies to different jurisdictions. We used the country's 57 administrative districts to proxy different jurisdictions. For the dependent variable, we combined the cost and effectiveness ratios with the districts' per capita health expenditure. The cost and effectiveness ratios were obtained from HIV/AIDS and malaria randomized controlled trials, which did either a prospective or retrospective cost-effectiveness analysis. The independent variables were district demographic and socioeconomic determinants of health. The study showed that intra-national variation resulted in different net benefits of the same health technology intervention if implemented in different districts in Zimbabwe. The study showed that population data, health data, infrastructure, demographic and health-seeking behavior had significant effects on the net margin benefit for the different districts. The net benefits also differed in terms of magnitude as a result of the local factors. Net benefit testing using local data is a very useful tool for assessing the transferability and further adoption of HCTs developed elsewhere. However, adopting interventions with a positive net benefit should also not be an end in itself. Information on positive or negative net benefit could also be used to ascertain either the level of future savings that a technology can realize or the level of investment needed for the particular technology to become beneficial.

  16. Intelligent Facades for High Performance Green Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyson, Anna

    Progress Towards Net-Zero and Net-Positive-Energy Commercial Buildings and Urban Districts Through Intelligent Building Envelope Strategies Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, wemore » have undertaken a high-performance building integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring onsite solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets. With a team that spans multiple stakeholders across disparate industries, from CPV to A&E partners that are responsible for the design and development of District and Regional Scale Urban Development, this project demonstrates that integrating utility-scale high efficiency CPV installations with urban and suburban environments is both viable and desirable within the marketplace. The historical schism between utility scale CPV and BIPV has been one of differing scale and cultures. There is no technical reason why utility-scale CPV cannot be located within urban embedded district scale sites of energy harvesting. New models for leasing large areas of district scale roofs and facades are emerging, such that the model for utility scale energy harvesting can be reconciled to commercial and public scale building sites and campuses. This consortium is designed to unite utility scale solar harvesting into building applications for smart grid development.« less

  17. Feasibility of geothermal space/water heating for Mammoth Lakes Village, California. Final report, September 1976--September 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sims, A.V.; Racine, W.C.

    1977-12-01

    Results of a study to determine the technical, economic, and environmental feasibility of geothermal district heating for Mammoth Lakes Village, California are reported. The geothermal district heating system selected is technically feasible and will use existing technology in its design and operation. District heating can provide space and water heating energy for typical customers at lower cost than alternative sources of energy. If the district heating system is investor owned, lower costs are realized after five to six years of operation, and if owned by a nonprofit organization, after zero to three years. District heating offers lower costs than alternativesmore » much sooner in time if co-generation and/or DOE participation in system construction are included in the analysis. During a preliminary environmental assessment, no potential adverse environmental impacts could be identified of sufficient consequence to preclude the construction and operation of the proposed district heating system. A follow-on program aimed at implementing district heating in Mammoth is outlined.« less

  18. Outcomes of polio eradication activities in Uttar Pradesh, India: the Social Mobilization Network (SM Net) and Core Group Polio Project (CGPP)

    PubMed Central

    2011-01-01

    Background The primary strategy to interrupt transmission of wild poliovirus in India is to improve supplemental immunization activities and routine immunization coverage in priority districts with a focus on 107 high-risk blocks of western Uttar Pradesh and central Bihar. Villages or urban areas with a history of wild poliovirus transmission, or hard-to-reach or resistant populations are categorized as high-risk areas within blocks. The Social Mobilization Network (SM Net) was formed in Uttar Pradesh in 2003 to support polio eradication efforts through improved planning, implementation and monitoring of social mobilization activities in those high-risk areas. In this paper, we examine the vaccination outcomes in districts of SM Net where the CORE Group works. Methods We carried out a secondary data analysis of routine monitoring information collected by the SM Net and the Government of India. These data include information about vaccination outcomes in SM Net areas and non-SM Net areas within the districts where the CORE Group operates. Statistical analysis was used to compare, between SM Net and non-SM Net areas, vaccination outcomes considered sensitive to social mobilization efforts of the SM Net. We employed Generalized Estimating Equations (GEE) statistical method to account for Intra-cluster Correlation (ICC), and used 'Quasi-likelihood under the independence model criterion (QIC)' as the model selection method. Results Vaccination outcomes in SM Net areas were as high as or higher than in non-SM Net areas. There was considerable variation in vaccination outcomes between districts. Conclusions While not conclusive, the results suggest that the social mobilization efforts of the SM Net and the CORE Group are helping to increase vaccination levels in high-risk areas of Uttar Pradesh. Vaccination outcomes in CORE Group areas were equal or higher than in non-CORE, non-SM Net areas. This occurred even though SM Net areas are those with more community resistance to polio vaccination and/or are have harder-to-reach populations than non-SM Net areas. Other likely explanations for the relatively good vaccination performance in SM Net areas are not apparent. PMID:21569256

  19. Evaluation of Advanced Stirling Convertor Net Heat Input Correlation Methods Using a Thermal Standard

    NASA Technical Reports Server (NTRS)

    Briggs, Maxwell; Schifer, Nicholas

    2011-01-01

    Test hardware used to validate net heat prediction models. Problem: Net Heat Input cannot be measured directly during operation. Net heat input is a key parameter needed in prediction of efficiency for convertor performance. Efficiency = Electrical Power Output (Measured) divided by Net Heat Input (Calculated). Efficiency is used to compare convertor designs and trade technology advantages for mission planning.

  20. Free distribution of insecticidal bed nets improves possession and preferential use by households and is equitable: findings from two cross-sectional surveys in thirteen malaria endemic districts of Bangladesh.

    PubMed

    Ahmed, Syed M; Hossain, Shamim; Kabir, Mohammad M; Roy, Sanjit

    2011-12-13

    BRAC, an indigenous non-governmental development organization (NGO), has been implementing a programme to prevent and control malaria in the 13 malaria-endemic districts of Bangladesh since 2007. One of the critical preventive interventions is the distribution of insecticidal bed nets (long-lasting insecticide-treated nets, LLINs and insecticide-treated ordinary nets, ITNs) to the community free of cost. This study aimed to assess progress in the possession, preferential use, and knowledge on use of the LLIN/ITNs including the programme's avowed pro-poor inclination one and three and half years after intervention began. A convenient sampling strategy based on malaria endemicity in the districts was adopted. First, thirty upazila (sub-district, with a population around 250,000)s were selected at random, with high prevalent districts contributing more upazilas; second, from each upazila, one (2008) to two (2011) villages (covered by insecticidal bed net distribution programme) were selected. From each village, households that had either one under-five child and/or a pregnant woman were included in the survey, one household being included only once. Data were collected using a pre-tested structured questionnaire. In all, 3,760 households in 2008 and 7,895 households in 2011 were surveyed for collecting relevant information. Proportion of households with at least one LLIN, and at least one LLIN/ITN increased (22-59 to 62-67% and 22-64% to 74-76% respectively) over time, including increase in the mean number of LLIN/ITNs per household (≤ 1 to 1 +). The programme achieved > 80% coverage in sleeping under an LLIN/ITN in the case of under-five children and pregnant women, especially in the high-endemic districts. Knowledge regarding critical time of hanging the net also increased over time (7-22 to 44-54%), but remained low. The pro-poor inclination of the programme is reflected in the status of relevant indicators according to self-rated poverty status of the households. There has been a substantial improvement in possession and usage of insecticidal bed nets especially for the two most vulnerable groups (under-five children and pregnant women), including a reduction of gaps between the high and low endemic districts, and the deficit and non-deficit households during the study period.

  1. The analysis of thermal network of district heating system from investor point of view

    NASA Astrophysics Data System (ADS)

    Takács, Ján; Rácz, Lukáš

    2016-06-01

    The hydraulics of a thermal network of a district heating system is a very important issue, to which not enough attention is often paid. In this paper the authors want to point out some of the important aspects of the design and operation of thermal networks in district heating systems. The design boundary conditions of a heat distribution network and the requirements on active pressure - circulation pump - influencing the operation costs of the centralized district heating system as a whole, are analyzed in detail. The heat generators and the heat exchange stations are designed according to the design heat loads after thermal insulation, and modern boiler units are installed in the heating plant.

  2. Why is there net surface heating over the Antarctic Circumpolar Current?

    NASA Astrophysics Data System (ADS)

    Czaja, Arnaud; Marshall, John

    2015-05-01

    Using a combination of atmospheric reanalysis data, climate model outputs and a simple model, key mechanisms controlling net surface heating over the Southern Ocean are identified. All data sources used suggest that, in a streamline-averaged view, net surface heating over the Antarctic Circumpolar Current (ACC) is a result of net accumulation of solar radiation rather than a result of heat gain through turbulent fluxes (the latter systematically cool the upper ocean). It is proposed that the fraction of this net radiative heat gain realized as net ACC heating is set by two factors. First, the sea surface temperature at the southern edge of the ACC. Second, the relative strength of the negative heatflux feedbacks associated with evaporation at the sea surface and advection of heat by the residual flow in the oceanic mixed layer. A large advective feedback and a weak evaporative feedback maximize net ACC heating. It is shown that the present Southern Ocean and its circumpolar current are in this heating regime.

  3. IDEA Clean Energy Application Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thornton, Robert P.

    The DOE Clean Energy Application Centers were launched with a goal of focusing on important aspects of our nation’s energy supply including Efficiency, Reliability and Resiliency. Clean Energy solutions based on Combined Heat & Power (CHP), District Energy and Waste Heat Recovery are at the core of ensuring a reliable and efficient energy infrastructure for campuses, communities, and industry and public enterprises across the country. IDEA members which include colleges and universities, hospitals, airports, downtown utilities as well as manufacturers, suppliers and service providers have long-standing expertise in the planning, design, construction and operations of Clean Energy systems. They representmore » an established base of successful projects and systems at scale and serve important and critical energy loads. They also offer experience, lessons learned and best practices which are of immense value to the sustained growth of the Clean Energy sector. IDEA has been able to leverage the funds from the project award to raise the visibility, improve the understanding and increase deployment CHP, District Energy and Waste Heat Recovery solutions across the regions of our nation, in collaboration with the regional CEAC’s. On August 30, 2012, President Obama signed an Executive Order to accelerate investments in industrial energy efficiency (EE), including CHP and set a national goal of 40 GW of new CHP installation over the next decade IDEA is pleased to have been able to support this Executive Order in a variety of ways including raising awareness of the goal through educational workshops and Conferences and recognizing the installation of large scale CHP and district energy systems. A supporting key area of collaboration has involved IDEA providing technical assistance on District Energy/CHP project screenings and feasibility to the CEAC’s for multi building, multi-use projects. The award was instrumental in the development of a first-order screening/feasibility tool for these types of community energy projects. The Excel based tool incorporates hourly climate based building loads data to arrive at the composite energy demand for the district and compares the Net Present Value (NPV) of the costs of CHP/DE alternatives. This tool has been used to provide assistance to several projects in the Northeast, Mid-Atlantic, Intermountain and Pacific Regions. The tool was disseminated to the CEACs and supplemented by a Training Webinar and a How to Guide IDEA produced a US Community Energy Development Guide to support mayors, planners, community leaders, real estate developers and economic development officials who are interested in planning more sustainable urban energy infrastructure, creating community energy master plans and implementing CHP/ District Energy systems in cities, communities and towns. IDEA has collected industry data and provided a comprehensive data set containing information on District Energy installations in the US. District energy systems are present in 49 states and theDistrict of Columbia. Of the 597 systems 55% were DE alone while the remainder was some combination of CHP, district heating, and district cooling. District energy systems that do not currently involve electric generation are strong near-term candidates for the adoption of CHP due to the magnitude of their aggregated thermal load. This data has helped inform specific and targeted initiatives including technical assistance provided by the CEAC’s for EPA’s Boiler MACT Compliance by large District Heating System boilers. These outcomes have been greatly enabled by the close coordination and collaboration with DOE CEAC leadership and with the eight regional US DOE Clean Energy Application Centers and the award’s incremental funding has allowed IDEA to leverage our resources to be an effective champion for Clean Energy.« less

  4. Geothermal space/water heating for City of Mammoth Lakes, California. Draft final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sims, A.V.; Racine, W.C.

    1977-09-01

    The results of a study to determine the technical, economic and environmental feasibility of geothermal district heating for Mammoth Lakes Village, California are presented. The geothermal district heating system selected is technically feasible and uses existing technology in its design and operation. During a preliminary environmental assessment, no potential adverse environmental impacts could be identified of sufficient consequence to preclude the construction and operation of the proposed district heating system. A follow-on program aimed at implementing district heating in Mammoth is outlined.

  5. District heating campaign in Sweden

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stalebrant, R.E.

    During the fall of 1994 a district heating campaign was conducted in Sweden. The campaign was initiated because the Swedish district heating companies agreed that it was time to increase knowledge and awareness of district heating among the general public, especially among potential customers. The campaign involved many district heating companies and was organized as a special project. Advertising companies, media advisers, consultants and investigators were also engaged. The campaign was conducted in two stages, a national campaign followed by local campaign was conducted in two stages, a national campaign followed by local campaigns. The national campaign was conducted duringmore » two weeks of November 1994 and comprised advertising on commercial TV and in the press.« less

  6. Heat demand mapping and district heating grid expansion analysis: Case study of Velika Gorica

    NASA Astrophysics Data System (ADS)

    Dorotić, Hrvoje; Novosel, Tomislav; Duić, Neven; Pukšec, Tomislav

    2017-10-01

    Highly efficient cogeneration and district heating systems have a significant potential for primary energy savings and the reduction of greenhouse gas emissions through the utilization of a waste heat and renewable energy sources. These potentials are still highly underutilized in most European countries. They also play a key role in the planning of future energy systems due to their positive impact on the increase of integration of intermittent renewable energy sources, for example wind and solar in a combination with power to heat technologies. In order to ensure optimal levels of district heating penetration into an energy system, a comprehensive analysis is necessary to determine the actual demands and the potential energy supply. Economical analysis of the grid expansion by using the GIS based mapping methods hasn't been demonstrated so far. This paper presents a heat demand mapping methodology and the use of its output for the district heating network expansion analysis. The result are showing that more than 59% of the heat demand could be covered by the district heating in the city of Velika Gorica, which is two times more than the present share. The most important reason of the district heating's unfulfilled potential is already existing natural gas infrastructure.

  7. Tuberculosis cure rates and the ETR.Net: investigating the quality of reporting treatment outcomes from primary healthcare facilities in Mpumalanga province, South Africa.

    PubMed

    Dreyer, A W; Mbambo, D; Machaba, M; Oliphant, C E M; Claassens, M M

    2017-03-10

    Tuberculosis control programs rely on accurate collection of routine surveillance data to inform program decisions including resource allocation and specific interventions. The electronic TB register (ETR.Net) is dependent on accurate data transcription from both paperbased clinical records and registers at the facilities to report treatment outcome data. The study describes the quality of reporting of TB treatment outcomes from facilities in the Ehlanzeni District, Mpumalanga Province. A descriptive crossectional study of primary healthcare facilities in the district for the period 1 January - 31 December 2010 was performed. New smear positive TB cure rate data was obtained from the ETR.Net followed by verification of paperbased clinical records, both TB folders and the TB register, of 20% of all new smear positive cases across the district for correct reporting to the ETR.Net. Facilities were grouped according to high (>70%) and low cure rates (≤ 70%) as well as high (> 20%) and low (≤ 20%) error proportions in reporting. Kappa statistic was used to determine agreement between paperbased record, TB register and ETR.Net. Of the100 facilities (951 patient clinical records), 51(51%) had high cure rates and high error proportions, 14(14%) had a high cure rate and low error proportion whereas 30(30%) had low cure rates and high error proportions and five (5%) had a low cure rate with low error proportion. Fair agreement was observed (Kappa = 0.33) overall and between registers. Of the 473 patient clinical records which indicated cured, 383(81%) was correctly captured onto the ETR.Net, whereas 51(10.8%) was incorrectly captured and 39(8.2%) was not captured at all. Over reporting of treatment success of 12% occurred on the ETR.Net. The high error proportion in reporting onto the ETR.Net could result in a false sense of improvement in the TB control programme in the Ehlanzeni district.

  8. District heating and cooling systems for communities through power plant retrofit distribution network. Volume 3. Final report, September 1, 1978-May 31, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This final report of Phase I of the study presents Task 4, Technical Review and Assessment. The most-promising district-heating concept identified in the Phase I study for the Public Service Electric and Gas Company, Newark, New Jersey, is a hot-water system in which steam is extracted from an existing turbine and used to drive a new, small backpressure turbine-generator. The backpressure turbine provides heat for district heating and simultaneously provides additional electric-generating capacity to partially offset the capacity lost due to the steam extraction. This approach is the most-economical way to retrofit the stations studied for district heating while minimizingmore » electric-capacity loss. Nine fossil-fuel-fired stations within the PSE and G system were evaluated for possibly supplying heat for district heating and cooling in cogeneration operations, but only three were selected to supply the district-heating steam. They are Essex, Hudson, and Bergen. Plant retrofit, thermal distribution schemes, consumer-conversion scheme, and consumer-metering system are discussed. Extensive technical information is provided in 16 appendices, additional tables, figures, and drawings. (MCW)« less

  9. Heat Wave Vulnerability Mapping for India.

    PubMed

    Azhar, Gulrez; Saha, Shubhayu; Ganguly, Partha; Mavalankar, Dileep; Madrigano, Jaime

    2017-03-30

    Assessing geographic variability in heat wave vulnerability forms the basis for planning appropriate targeted adaptation strategies. Given several recent deadly heatwaves in India, heat is increasingly being recognized as a public health problem. However, to date there has not been a country-wide assessment of heat vulnerability in India. We evaluated demographic, socioeconomic, and environmental vulnerability factors and combined district level data from several sources including the most recent census, health reports, and satellite remote sensing data. We then applied principal component analysis (PCA) on 17 normalized variables for each of the 640 districts to create a composite Heat Vulnerability Index (HVI) for India. Of the total 640 districts, our analysis identified 10 and 97 districts in the very high and high risk categories (> 2SD and 2-1SD HVI) respectively. Mapping showed that the districts with higher heat vulnerability are located in the central parts of the country. On examination, these are less urbanized and have low rates of literacy, access to water and sanitation, and presence of household amenities. Therefore, we concluded that creating and mapping a heat vulnerability index is a useful first step in protecting the public from the health burden of heat. Future work should incorporate heat exposure and health outcome data to validate the index, as well as examine sub-district levels of vulnerability.

  10. Status of tubular SOFC field unit demonstrations

    NASA Astrophysics Data System (ADS)

    George, Raymond A.

    Siemens Westinghouse is in the final stage of its tubular solid oxide fuel cell (SOFC) development program, and the program emphasis has shifted from basic technology development to cost reduction, scale-up and demonstration of pre-commercial power systems at customer sites. This paper describes our field unit demonstration program including the EDB/ELSAM 100-kW e combined heat and power (CHP) system, the Southern California Edison (SCE) 220-kW e pressurized SOFC/gas turbine (PSOFC/GT) power system, and the planned demonstrations of commercial prototype power systems. In the Spring of 1999, the EDB/ELSAM 100-kW e SOFC-CHP system produced 109 kW e net AC to the utility grid at 46% electrical efficiency and 65 kW t to the hot water district heating system, verifying the analytical predictions. The SCE 220-kW e PSOFC/GT power system will undergo factory startup in the Fall of 1999.

  11. Working and Net Available Shell Storage Capacity

    EIA Publications

    2017-01-01

    Working and Net Available Shell Storage Capacity is the U.S. Energy Information Administration’s (EIA) report containing storage capacity data for crude oil, petroleum products, and selected biofuels. The report includes tables detailing working and net available shell storage capacity by type of facility, product, and Petroleum Administration for Defense District (PAD District). Net available shell storage capacity is broken down further to show the percent for exclusive use by facility operators and the percent leased to others. Crude oil storage capacity data are also provided for Cushing, Oklahoma, an important crude oil market center. Data are released twice each year near the end of May (data for March 31) and near the end of November (data for September 30).

  12. Prospects for development of heat supply systems in high-rise districts

    NASA Astrophysics Data System (ADS)

    Zhila, Viktor; Solovyeva, Elena

    2018-03-01

    The article analyzes the main advantages and disadvantages of centralized and decentralized heat supply systems in high-rise districts. The main schemes of centralized heat supply systems are considered. They include centralized heat supply from boiler houses, centralized heat supply from autonomous heat sources, heat supply from roof boiler houses and door-to-door heating supply. For each of these variant, the gas distribution systems are considered and analyzed. These systems vary depending on the heat source location. For each of these systems, technical and economic indicators are taken into account, the analysis of which allows choosing the best option for districts where high-rise buildings predominate.

  13. Heat pumps in the PESAG supply district

    NASA Astrophysics Data System (ADS)

    Osterhus, A.

    1980-04-01

    The paper examines the feasibility of using large scale heat pumps in the PESAG (Paderborner Elektrizitaetswerk und Strassenbahn AG) power supply district. It is shown that due to favorable geological factors in the district which allow the tapping of ground water, the market share for heat pumps will increase steadily. Topics discussed include: calculation of electricity consumption, operating experiences with heat pumps in one- and two-family houses, heat pumps in multifamily houses, and industrially used systems.

  14. A qualitative study on caretakers' perceived need of bed-nets after reduced malaria transmission in Zanzibar, Tanzania

    PubMed Central

    2012-01-01

    Background The elimination of malaria in Zanzibar is highly dependent on sustained effective coverage of bed-nets to avoid malaria resurgence. The Health Belief Model (HBM) framework was used to explore the perceptions of malaria and bed-net use after a noticeable reduction in malaria incidence. Methods Nineteen in-depth interviews were conducted with female and male caretakers of children under five in North A district, Zanzibar. Deductive content analysis was used to identify meaning units that were condensed, coded and assigned to pre-determined elements of the HBM. Results Awareness of malaria among caretakers was high but the illness was now seen as easily curable and uncommon. In addition to the perceived advantage of providing protection against malaria, bed-nets were also thought to be useful for avoiding mosquito nuisance, especially during the rainy season when the malaria and mosquito burden is high. The discomfort of sleeping under a net during the hot season was the main barrier that interrupted consistent bed-net usage. The main cue to using a bed-net was high mosquito density, and children were prioritized when it came to bed-net usage. Caretakers had high perceived self-efficacy and did not find it difficult to use bed-nets. Indoor Residual Spraying (IRS), which was recognized as an additional means of mosquito prevention, was not identified as an alternative for bed-nets. A barrier to net ownership was the increasingly high cost of bed-nets. Conclusions Despite the reduction in malaria incidence and the resulting low malaria risk perceptions among caretakers, the benefit of bed-nets as the most proficient protection against mosquito bites upholds their use. This, in combination with the perceived high self-efficacy of caretakers, supports bed-net usage, while seasonality interrupts consistent use. High effective coverage of bed-nets could be further improved by reinforcing the benefits of bed-nets, addressing the seasonal heat barrier by using nets with larger mesh sizes and ensuring high bed-net ownership rates through sustainable and affordable delivery mechanisms. PMID:22863188

  15. A Model for Determining School District Cash Flow Needs.

    ERIC Educational Resources Information Center

    Dembowski, Frederick L.

    This paper discusses a model to optimize cash management in school districts. A brief discussion of the cash flow pattern of school districts is followed by an analysis of the constraints faced by the school districts in their investment planning process. A linear programming model used to optimize net interest earnings on investments is developed…

  16. Evaluation of thermal energy storage for the proposed Twin Cities District Heating system. [using cogeneration heat production and aquifiers for heat storage

    NASA Technical Reports Server (NTRS)

    Meyer, C. F.

    1980-01-01

    The technical and economic feasibility of incorporating thermal energy storage components into the proposed Twin Cities District heating project was evaluated. The technical status of the project is reviewed and conceptual designs of district heating systems with and without thermal energy storage were compared in terms of estimated capital requirements, fuel consumption, delivered energy cost, and environmental aspects. The thermal energy storage system is based on cogeneration and the storage of heat in aquifers.

  17. School District Size and the Deployment of Personnel Resources.

    ERIC Educational Resources Information Center

    Daft, Richard L.; Becker, Selwyn W.

    1978-01-01

    The administrative component was found to receive a smaller proportion of salaries in large districts, while clerical and maintenance service proportions increased, producing a net effect of larger overhead costs in this study of high school districts in the midwestern U.S. (KR)

  18. Life cycle assessment of biochar application in Vietnam using two pyrolysis technologies

    NASA Astrophysics Data System (ADS)

    Mohammadi, Ali; Cowie, Annette; Mai, Thi Lan Anh; Anaya de la Rosa, Ruy; Kristiansen, Paul; Brandão, Miguel; Joseph, Stephen

    2016-04-01

    This study presents a comparative analysis of the environmental impacts of biochar systems in Vietnam using household scale and district scale pyrolysis technologies. At the household scale, pyrolytic cook-stoves were assumed to be used by households to produce biochar. The pyrolytic cook-stoves burn pyrolysis gases and use the heat for cooking. At the district scale, the BIGchar 2200 unit, a continuous operation system, is utilised to convert rice husk to biochar. This unit allows for easy capture of produced gases, which can be used to generate energy products, adding value to biochar production and decreasing environmental costs through the displacement of fossil fuels. The biochar produced from each system was assumed to be applied to paddy rice fields. Results from Life Cycle Assessment showed that biochar production at the both scales for application to the soil significantly improved environmental performance of 1 Mg of rice husk relative to the reference scenario (open burning of husk) across a range of impacts including climate change (CC), particulate matter and non-renewable energy (NRE) use. Net carbon abatement of biochar systems ranged from 355 to 427 kg CO2-eq Mg-1 of spring rice husk at the household scale and district scale, respectively. The district scale offered greater carbon abatement primarily due to the higher rate of LPG displaced by this unit.

  19. Energy recovery from waste incineration: assessing the importance of district heating networks.

    PubMed

    Fruergaard, T; Christensen, T H; Astrup, T

    2010-07-01

    Municipal solid waste incineration contributes with 20% of the heat supplied to the more than 400 district heating networks in Denmark. In evaluation of the environmental consequences of this heat production, the typical approach has been to assume that other (fossil) fuels could be saved on a 1:1 basis (e.g. 1GJ of waste heat delivered substitutes for 1GJ of coal-based heat). This paper investigates consequences of waste-based heat substitution in two specific Danish district heating networks and the energy-associated interactions between the plants connected to these networks. Despite almost equal electricity and heat efficiencies at the waste incinerators connected to the two district heating networks, the energy and CO(2) accounts showed significantly different results: waste incineration in one network caused a CO(2) saving of 48 kg CO(2)/GJ energy input while in the other network a load of 43 kg CO(2)/GJ. This was caused mainly by differences in operation mode and fuel types of the other heat producing plants attached to the networks. The paper clearly indicates that simple evaluations of waste-to-energy efficiencies at the incinerator are insufficient for assessing the consequences of heat substitution in district heating network systems. The paper also shows that using national averages for heat substitution will not provide a correct answer: local conditions need to be addressed thoroughly otherwise we may fail to assess correctly the heat recovery from waste incineration. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  20. Utilization Analysis in Low-Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB)

    DOE Data Explorer

    Jordan, Teresa E.

    2015-09-30

    This submission of Utilization Analysis data to the Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) is in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (project DE-EE0006726). The submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau Places within the study area. This was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. The MATLAB modules used in conjunction with GEOPHIRES, the MATLAB data input file, the GEOPHIRES output data file, and an explanation of the software components have been provided. Results of the SLCOH analysis appear on 4 .png image files as mapped risk of heat utilization. For each of the 4 image (.png) files, there is an accompanying georeferenced TIF (.tif) file by the same name. In addition to calculating SLCOH, this Task 4 also identified many sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing of the sites (.xlsx) and a map of these sites plotted as a layer onto different iterations of maps combining the three geological risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity) has been provided. In addition to the 6 image (.png) files of the maps in this series, a shape (.shp) file and 7 associated files are included as well. Finally, supporting files (.pdf) describing the utilization analysis methodology and summarizing the anticipated permitting for a deep district heating system are supplied. UPDATE: Newer version of the Utilization Analysis has been added here: https://gdr.openei.org/submissions/878

  1. GPFA-AB_Phase1UtilizationTask4DataUpload

    DOE Data Explorer

    Teresa E. Jordan

    2015-09-30

    This submission of Utilization Analysis data to the Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) is in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (project DE-EE0006726). The submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau ‘Places’ within the study area. This was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. The MATLAB modules used in conjunction with GEOPHIRES, the MATLAB data input file, the GEOPHIRES output data file, and an explanation of the software components have been provided. Results of the SLCOH analysis appear on 4 .png image files as mapped ‘risk’ of heat utilization. For each of the 4 image (.png) files, there is an accompanying georeferenced TIF (.tif) file by the same name. In addition to calculating SLCOH, this Task 4 also identified many sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing of the sites (.xlsx) and a map of these sites plotted as a layer onto different iterations of maps combining the three geological risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity) has been provided. In addition to the 6 image (.png) files of the maps in this series, a shape (.shp) file and 7 associated files are included as well. Finally, supporting files (.pdf) describing the utilization analysis methodology and summarizing the anticipated permitting for a deep district heating system are supplied.

  2. Optimal Operation System of the Integrated District Heating System with Multiple Regional Branches

    NASA Astrophysics Data System (ADS)

    Kim, Ui Sik; Park, Tae Chang; Kim, Lae-Hyun; Yeo, Yeong Koo

    This paper presents an optimal production and distribution management for structural and operational optimization of the integrated district heating system (DHS) with multiple regional branches. A DHS consists of energy suppliers and consumers, district heating pipelines network and heat storage facilities in the covered region. In the optimal management system, production of heat and electric power, regional heat demand, electric power bidding and sales, transport and storage of heat at each regional DHS are taken into account. The optimal management system is formulated as a mixed integer linear programming (MILP) where the objectives is to minimize the overall cost of the integrated DHS while satisfying the operation constraints of heat units and networks as well as fulfilling heating demands from consumers. Piecewise linear formulation of the production cost function and stairwise formulation of the start-up cost function are used to compute nonlinear cost function approximately. Evaluation of the total overall cost is based on weekly operations at each district heat branches. Numerical simulations show the increase of energy efficiency due to the introduction of the present optimal management system.

  3. Leading in Reading: Nebraska District Nets Success with Evidence-Based Learning

    ERIC Educational Resources Information Center

    Mueller, Melanie; Hanson, Ron

    2014-01-01

    Mueller and Hanson report on a continuous improvement process taking place in the Papillion-La Vista School District in Papillion, Nebraska, where a proactive stance to improved learning for all students focuses directly on the human element as the change agent. The district has implemented a systemic and systematic continuous improvement process…

  4. Improving urban district heating systems and assessing the efficiency of the energy usage therein

    NASA Astrophysics Data System (ADS)

    Orlov, M. E.; Sharapov, V. I.

    2017-11-01

    The report describes issues in connection with improving urban district heating systems from combined heat power plants (CHPs), to propose the ways for improving the reliability and the efficiency of the energy usage (often referred to as “energy efficiency”) in such systems. The main direction of such urban district heating systems improvement suggests transition to combined heating systems that include structural elements of both centralized and decentralized systems. Such systems provide the basic part of thermal power via highly efficient methods for extracting thermal power plants turbines steam, while peak loads are covered by decentralized peak thermal power sources to be mounted at consumers’ locations, with the peak sources being also reserve thermal power sources. The methodology was developed for assessing energy efficiency of the combined district heating systems, implemented as a computer software product capable of comparatively calculating saving on reference fuel for the system.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roshchanka, Volha; Evans, Meredydd

    The Russian district heating has a large energy-saving potential, and, therefore, need for investments. The scale of needed investments is significant: the government estimates that 70 percent of the district heating infrastructure needs replacement or maintenance, a reflection of decades of under investment. Government budgets will be unable to cover them, and iInvolvingement ofthe private industry will be critical to attracting the necessary investementis necessary. For private parties to invest in district heating facilities across Russia, and not only in pockets of already successful enterprises, regulators have to develop a comprehensive policy that works district heating systems under various conditionscost-reflectivemore » tariffs, metering, incentives for efficiency and social support for the neediest (instead of subsidies for all).« less

  6. Experience Gained on Direct Use of Low Enthalpy Energy in Hotel do Parque, S. Pedro do Sul, Portugal

    NASA Astrophysics Data System (ADS)

    Ferreira Gomes, L. M.; Neves Trota, A. P.; Reis Afonso de Albuquerque, F. J.

    2017-12-01

    Despite the high number of thermal flowing springs in Portugal mainland (up to 52 hot springs), ranging temperatures from 20 °C to 77 °C, and with significant water flow rate, few district heating system were implemented in Portugal. Here we present the São Pedro do Sul district heating system, located northern of Portugal. The thermal power plant was designed, completed, and commissioned in 2001 allowing the utilization of the geothermal heat by local users, as Hotel do Parque. The district heating system sums about 15 years of utilization without interruption and with minor drawbacks. On this paper we present the project overview along with thermal power plant specifications and data numbers. Heat comes from a 16.9 L/s of thermal water supplied by a natural spring and a nearby well. Heat from the spring and well sources is transferred to a secondary low mineralized water system by a plate heat exchanger, allowing the heating of space and domestic waters of hotel areas. Based on a theoretically cascade direct use of heat from a 67 °C to a 20 °C water temperature range, available heat totals 29.1*106 kWh yearly. However, past and actual use of heat only reaches around 1.6% of that figure. By comparing with fossil heat sources, actual use of a natural heat source reduces a theoretically amount of 117.9 ton of CO2 emissions by year. The successful use of this district heating system can promote local expansion of new users and other possible heat uses of this renewable energy, giving chance for the district heating system saturation.

  7. Implementation strategies to increase access and demand of long-lasting insecticidal nets: a before-and-after study and scale-up process in Mozambique.

    PubMed

    Arroz, Jorge A H; Mendis, Chandana; Pinto, Liliana; Candrinho, Baltazar; Pinto, João; Martins, Maria do Rosário O

    2017-10-25

    The universal coverage bed nets campaign is a proven health intervention promoting increased access, ownership, and use of bed nets to reduce malaria burden. This article describes the intervention and implementation strategies that Mozambique carried out recently in order to improve access and increase demand for long-lasting insecticidal nets (LLINs). A before-and-after study with a control group was used during Stage I of the implementation process. The following strategies were tested in Stage I: (1) use of coupons during household registration; (2) use of stickers to identify the registered households; (3) new LLIN ascription formula (one LLIN for every two people). In Stage II, the following additional strategies were implemented: (4) mapping and micro-planning; (5) training; and (6) supervision. Odds ratio (OR) and 95% confidence interval (CI) were used to compare and establish differences between intervened and control districts in Stage I. Main outcomes were: percentage of LLINs distributed, percentage of target households benefited. In Stage I, 87.8% (302,648) of planned LLINs were distributed in the intervention districts compared to 77.1% (219,613) in the control districts [OR: 2.14 (95% CI 2.11-2.16)]. Stage I results also showed that 80.6% (110,453) of households received at least one LLIN in the intervention districts compared to 72.8% (87,636) in the control districts [OR: 1.56 (95% CI 1.53-1.59)]. In Stage II, 98.4% (3,536,839) of the allocated LLINs were delivered, covering 98.6% (1,353,827) of the registered households. Stage I results achieved better LLINs and household coverage in districts with the newly implemented strategies. The results of stage II were also encouraging. Additional strategies adaptation is required for a wide-country LLIN campaign.

  8. Mapping Extreme Heat Vulnerability and Health Outcomes to inform the District of Columbia's Climate Adaptation Plan

    NASA Astrophysics Data System (ADS)

    Declet-Barreto, J.; Wilhelmi, O.; Goggans, A.

    2016-12-01

    In this collaborative engagement, scientists are partnering with the District of Columbia (DC) to develop an extreme heat vulnerability assessment. To do so, we map socio-demographic and built environment indicators of extreme heat vulnerability in Census Tracts in DC neighborhoods. In order to provide information useful for DC public health and urban planning practitioners, we aggregate the indicators into an index of extreme heat vulnerability. We compare the index against heat-related call data from DC's 911 system to better understand the socio-spatial distribution of extreme heat-related health outcomes. Our assessment can help inform the District's Climate Adaptation Plan as well as increase public engagement in reducing vulnerability to extreme heat.

  9. Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jarrell, Mark

    Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersson, B.

    This paper will present the status of the development of district cooling systems in Scandinavia over the last 5 years. It will describe the technologies used in the systems that have been constructed as well as the options considered in different locations. It will identify the drivers for the development of the cooling business to-date, and what future drivers for a continuing development of district cooling in Sweden. To-date, approximately 25 different cities of varying sizes have completed feasibility studies to determine if district cooling is an attractive option. In a survey, that was conducted by the Swedish District Heatingmore » Association, some 25 cities expected to have district cooling systems in place by the year 2000. In Sweden, district heating systems with hot water is very common. In many cases, it is simply an addition to the current service for the district heating company to also supply district cooling to the building owners. A parallel from this can be drawn to North America where district cooling systems now are developing rapidly. I am convinced that in these cities a district heating service will be added as a natural expansion of the district cooling company`s service.« less

  11. Biomass district heating methodology and pilot installations for public buildings groups

    NASA Astrophysics Data System (ADS)

    Chatzistougianni, N.; Giagozoglou, E.; Sentzas, K.; Karastergios, E.; Tsiamitros, D.; Stimoniaris, D.; Stomoniaris, A.; Maropoulos, S.

    2016-11-01

    The objective of the paper is to show how locally available biomass can support a small-scale district heating system of public buildings, especially when taking into account energy audit in-situ measurements and energy efficiency improvement measures. The step-by-step methodology is presented, including the research for local biomass availability, the thermal needs study and the study for the biomass district heating system, with and without energy efficiency improvement measures.

  12. The assessment of global thermo-energy performances of existing district heating systems optimized by harnessing renewable energy sources

    NASA Astrophysics Data System (ADS)

    Şoimoşan, Teodora M.; Danku, Gelu; Felseghi, Raluca A.

    2017-12-01

    Within the thermo-energy optimization process of an existing heating system, the increase of the system's energy efficiency and speeding-up the transition to green energy use are pursued. The concept of multi-energy district heating system, with high harnessing levels of the renewable energy sources (RES) in order to produce heat, is expected to be the key-element in the future urban energy infrastructure, due to the important role it can have in the strategies of optimizing and decarbonizing the existing district heating systems. The issues that arise are related to the efficient integration of different technologies of harnessing renewable energy sources in the energy mix and to the increase of the participation levels of RES, respectively. For the holistic modeling of the district heating system, the concept of the energy hub was used, where the synergy of different primary forms of entered energy provides the system a high degree energy security and flexibility in operation. The optimization of energy flows within the energy hub allows the optimization of the thermo-energy district system in order to approach the dual concept of smart city & smart energy.

  13. A Computational Methodology for Simulating Thermal Loss Testing of the Advanced Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Reid, Terry V.; Wilson, Scott D.; Schifer, Nicholas A.; Briggs, Maxwell H.

    2012-01-01

    The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two highefficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. In an effort to improve net heat input predictions, numerous tasks have been performed which provided a more accurate value for net heat input into the ASCs, including the use of multidimensional numerical models. Validation test hardware has also been used to provide a direct comparison of numerical results and validate the multi-dimensional numerical models used to predict convertor net heat input and efficiency. These validation tests were designed to simulate the temperature profile of an operating Stirling convertor and resulted in a measured net heat input of 244.4 W. The methodology was applied to the multi-dimensional numerical model which resulted in a net heat input of 240.3 W. The computational methodology resulted in a value of net heat input that was 1.7 percent less than that measured during laboratory testing. The resulting computational methodology and results are discussed.

  14. Particulate matter emissions from combustion of wood in district heating applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghafghazi, S.; Sowlati, T.; Sokhansanj, Shahabaddine

    2011-01-01

    The utilization of wood biomass to generate district heat and power in communities that have access to this energy source is increasing. In this paper the effect of wood fuel properties, combustion condition, and flue gas cleaning system on variation in the amount and formation of particles in the flue gas of typical district heating wood boilers are discussed based on the literature survey. Direct measurements of particulate matter (PM) emissions from wood boilers with district heating applications are reviewed and presented. Finally, recommendations are given regarding the selection of wood fuel, combustion system condition, and flue gas cleaning systemmore » in district heating systems in order to meet stringent air quality standards. It is concluded that utilization of high quality wood fuel, such as wood pellets produced from natural, uncontaminated stem wood, would generate the least PM emissions compared to other wood fuel types. Particulate matter emissions from grate burners equipped with electrostatic precipitators when using wood pellets can be well below stringent regulatory emission limit such as particulate emission limit of Metro Vancouver, Canada.« less

  15. Evaluation of a national universal coverage campaign of long-lasting insecticidal nets in a rural district in north-west Tanzania.

    PubMed

    West, Philippa A; Protopopoff, Natacha; Rowland, Mark W; Kirby, Matthew J; Oxborough, Richard M; Mosha, Franklin W; Malima, Robert; Kleinschmidt, Immo

    2012-08-10

    Insecticide-treated nets (ITN) are one of the most effective measures for preventing malaria. Mass distribution campaigns are being used to rapidly increase net coverage in at-risk populations. This study had two purposes: to evaluate the impact of a universal coverage campaign (UCC) of long-lasting insecticidal nets (LLINs) on LLIN ownership and usage, and to identify factors that may be associated with inadequate coverage. In 2011 two cross-sectional household surveys were conducted in 50 clusters in Muleba district, north-west Tanzania. Prior to the UCC 3,246 households were surveyed and 2,499 afterwards. Data on bed net ownership and usage, demographics of household members and household characteristics including factors related to socio-economic status were gathered, using an adapted version of the standard Malaria Indicator Survey. Specific questions relating to the UCC process were asked. The proportion of households with at least one ITN increased from 62.6% (95% Confidence Interval (CI) = 60.9-64.2) before the UCC to 90.8% (95% CI = 89.0-92.3) afterwards. ITN usage in all residents rose from 40.8% to 55.7%. After the UCC 58.4% (95% CI = 54.7-62.1) of households had sufficient ITNs to cover all their sleeping places. Households with children under five years (OR = 2.4, 95% CI = 1.9-2.9) and small households (OR = 1.9, 95% CI = 1.5-2.4) were most likely to reach universal coverage. Poverty was not associated with net coverage. Eighty percent of households surveyed received LLINs from the campaign. The UCC in Muleba district of Tanzania was equitable, greatly improving LLIN ownership and, more moderately, usage. However, the goal of universal coverage in terms of the adequate provision of nets was not achieved. Multiple, continuous delivery systems and education activities are required to maintain and improve bed net ownership and usage.

  16. Economic Assessment of Rural District Heating by Bio-Steam Supplied by a Paper Mill in Canada

    ERIC Educational Resources Information Center

    Marinova, Mariya; Beaudry, Catherine; Taoussi, Abdelaziz; Trepanier, Martin; Paris, Jean

    2008-01-01

    The article investigates the feasibility of district heating in a small town adjacent to a Kraft pulp mill in eastern Canada. A detailed heat demand analysis is performed for all buildings using a geographical information system and archived data provided by the municipality. The study shows that the entire space heating requirement of the town…

  17. Moorhead district heating, phase 2

    NASA Astrophysics Data System (ADS)

    Sundberg, R. E.

    1981-01-01

    The feasibility of developing a demonstration cogeneration hot water district heating system was studied. The district heating system would use coal and cogenerated heat from the Moorhead power plant to heat the water that would be distributed through underground pipes to customers or their space and domestic water heating needs, serving a substantial portion of the commercial and institutional loads as well as single and multiple family residences near the distribution lines. The technical feasibility effort considered the distribution network, retrofit of the power plant, and conversion of heating systems in customers' buildings to use hot water from the system. The system would be developed over six years. The economic analysis consisted of a market assessment and development of business plans for construction and operation of the system. Rate design methodology, institutional issues, development risk, and the proposal for implementation are discussed.

  18. A quantitative determination of air-water heat fluxes in Hermit Lake, New Hampshire under varying meteorological conditions, time of day, and time of year

    NASA Astrophysics Data System (ADS)

    Kyper, Nicholas D.

    An extensive heat flux study is performed at Hermit Lake, New Hampshire from May 26, 2010 till November 7, 2010 to determine the effects of the five individual heat fluxes on Hermit Lake and the surrounding amphibian community. Hermit Lake was chosen due to the relatively long meteorological observations record within the White Mountains of New Hampshire, a new lakeside meteorological station, and ongoing phenology studies of the surrounding eco-system. Utilizing meteorological data from the lakeside weather station and moored water temperature sensors, the incident (Qi), blackbody ( Qbnet ), latent (Qe), sensible (Q s), and net (Qn) heat fluxes are calculated. The incident heat flux is the dominate term in the net flux, accounting for 93% of the variance found in Qn and producing a heat gain of ˜ 19x108 J m-2 throughout the period of study. This large gain produces a net gain of heat in the lake until October 1, 2010, where gains by Qi are offset by the large combined losses of Qbnet , Qs, and Qe thereby producing a gradual decline of heat within the lake. The latent and blackbody heat fluxes produce the largest losses of heat in the net heat flux with a total losses of ˜ -8x108 J m-2 and ˜ -7x108 J m-2, respectively. The sensible heat flux is negligible, producing a total minimal loss of ˜ -1x108 J m-2. Overall the net heat produces a net gain of heat of 2x108 J m-2 throughout the study period. Frog calls indicative of breeding are recorded from May 26, 2010 until August 16, 2010. The spring peeper, American toad, and green frog each produced enough actively calling days to be compared to air temperature, surface water temperature, and wind speed data, as well as data from the five heat fluxes. Linear regression analysis reveals that certain water temperature thresholds affect the calling activities of the spring peeper and green frog, while higher wind speeds have a dramatic effect on the calling activities of both the green frog and American toad. All three frog species phenological activities are also affected by certain thresholds in the incident, blackbody, latent, sensible, and net heat

  19. [Level of microwave radiation from mobile phone base stations built in residential districts].

    PubMed

    Hu, Ji; Lu, Yiyang; Zhang, Huacheng; Xie, Hebing; Yang, Xinwen

    2009-11-01

    To investigate the condition of microwave radiation pollution from mobile phone base station built in populated area. Random selected 18 residential districts where had base station and 10 residential districts where had no base stations. A TES-92 electromagnetic radiation monitor were used to measure the intensity of microwave radiation in external and internal living environment. The intensities of microwave radiation in the exposure residential districts were more higher than those of the control residential districts (p < 0.05). There was a intensity peak at about 10 m from the station, it would gradually weaken with the increase of the distance. The level of microwave radiation in antenna main lobe region is not certainly more higher than the side lobe direction, and the side lobe direction also is not more lower. At the same district, where there were two base stations, the electromagnetic field nestification would take place in someplace. The intensities of microwave radiation outside the exposure windows in the resident room not only changed with distance but also with the height of the floor. The intensities of microwave radiation inside the aluminum alloys security net were more lower than those of outside the aluminum alloys security net (p < 0.05), but the inside or outside of glass-window appears almost no change (p > 0.05). Although all the measure dates on the ground around the base station could be below the primary standard in "environment electromagnetic wave hygienic standard" (GB9175-88), there were still a minorities of windows which exposed to the base station were higher, and the outside or inside of a few window was even higher beyond the primary safe level defined standard. The aluminum alloys security net can partly shield the microwave radiation from the mobile phone base station.

  20. Akranes and Borgarfjordur district heating system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ragnarsson, A.; Hrolfsson, I.

    1998-12-01

    Akranes and Borgarnes are two towns in the western part of Iceland, about 100 km north of Reykjavik. Geothermal investigations for Akranes started as early as around 1950; but in spite of several attempts, a geothermal field, which could be utilized economically, was not found for a long period. After the increase in oil prices in the early 1970s, further studies were carried out. On the basis of the results of those studies, it was decided to build a combined district heating system for Akranes, Borgarnes, Hvanneyri (agricultural school) and some farms in the Borgarfjordur region. The water is pipedmore » from the hot spring Deildartunga, which is one of the largest hot springs in the world. Besides that, the system utilizes two wells at the farm Baer. The utilization of the hot spring makes the system different from most other district heating systems in Iceland, which are based on water from wells. Akranes and Borgarfjordur District Heating System was established in 1979. Before that time, space heating in this area was both by oil (93%) and electricity (7%). The system has now been split into three companies: one that is responsible for all the hot water production and transmission, and one district heating system for each of the two communities.« less

  1. Net Heat of Combustion of AN-F-28 Aviation Gasolines

    NASA Technical Reports Server (NTRS)

    Jessup, R S; Cragoe, C S

    1945-01-01

    Experimental data on the heats of combustion and hydrogen contents of a number of aviation gasolines have been used in deriving a formula for computing net heat of combustion from (measured) gross heat of combustion. This formula appears to be sufficiently reliable for the purpose and has the advantage of making hydrogen determinations unnecessary. The data on heats of combustion are presented in tabular form, and in graphs showing the relation between net heat of combustion and (1) hydrogen content, (2) aniline point, (3) APO gravity, and (4) the product of aniline point and APO gravity. Data are given on the change in aniline point with time, and also the change resulting from the addition of xylidine.

  2. Effects of Reservoir Characteristics on Malaria and its vector Abundance: A Case Study of the Bongo District of Ghana

    NASA Astrophysics Data System (ADS)

    Ofosu, E.; Awuah, E.; Annor, F. O.

    2009-04-01

    In the seven (7) administrative zones of the Bongo District of the Upper East Region of Ghana, the occurrences of malaria and relative abundance of the principal malaria vector, Anopheles species, were studied as a function of the presence and characteristics of reservoirs during the rainy season. Case studies in the sub-Sahara Africa indicate that malaria transmission may increase decrease or remain largely unchanged as a consequence of reservoir presence. Analysis made, shows that the distance from reservoir to settlement and surface area of reservoirs significantly affected adult Anopheles mosquito abundance. Percentage of inhabitants using insecticide treated nets, livestock population density, human population density and Anopheles mosquito abundance significantly affected the occurrence of malaria. The results suggest that vector control targeted at reservoir characteristics and larval control, and supplemented by high patronage of insecticide treated nets may be an effective approach for epidemic malaria control in the Bongo District. Key Words: Bongo District, Reservoir, Anopheles species, Malaria, Vector abundance.

  3. Tropical Warm Pool Surface Heat Budgets and Temperature: Contrasts Between 1997-98 El Nino and 1998-99 La Nina

    NASA Technical Reports Server (NTRS)

    Chou, Shu-Hsien; Chou, Ming-Dah; Chan, Pui-King; Lin, Po-Hsiung; Wang, Kung-Hwa

    2003-01-01

    Seasonal and interannual variations of the net surface heating F(sub NET) and sea surface temperature tendency (T(sub s)/dt) in the tropical eastern Indian and western Pacific Oceans are studied. The surface heat fluxes are derived from the Special Sensor Microwave/Imager and Japanese Geostationary Meteorological Satellite radiance measurements for the period October 1997-September 2000. It is found that the magnitude of solar heating is lager than that of evaporative cooling, but the spatial variation of the latter is significantly large than the former. As a result, the spatial variations of seasonal and interannual variability of F(sub NET), follow closely that of evaporative cooling. Seasonal variations of F(sub NET) and T(sub s)/dt are significantly correlated, except for the equatorial western Pacific. The high correlation is primarily attributable to high correlation between seasonal cycles of solar heating and T(sub s)/dt. The change of F(sub NET) between 1997-98 El Nino and 1998-99 La Nina is significantly larger in the tropical eastern Indian Ocean than tropical western Pacific. For the former region, the reduced evaporative cooling arising from weakened winds during the El Nino is generally associated with enhanced solar heating due to decreased cloudiness, and thus increases the interannual variability of F(sub NET). For the latter region, the reduced evaporative cooling due to weakened winds is generally associated with but exceeds the reduced solar heating arising from increased cloudiness, and vise versa. Thus the interannual variability of F(sub NET) is reduced due to this offsetting effect. Interannual variations of F(sub NET) and T(sub s)/dt have very low correlation. This is most likely related to interannual variability of ocean dynamics, which includes the variations of solar radiation penetrating through oceanic mixed layer, upwelling of cold thermocline water, Indonesian throughflow for transporting heat from the Pacific to Indian Ocean, and interhemispheric transport in the Indian Ocean.

  4. Impact of Next Generation District Heating Systems on Distribution Network Heat Losses: A Case Study Approach

    NASA Astrophysics Data System (ADS)

    Li, Yu; Rezgui, Yacine

    2018-01-01

    District heating (DH) is a promising energy pathway to alleviate environmental negative impacts induced by fossil fuels. Improving the performance of DH systems is one of the major challenges facing its wide adoption. This paper discusses the heat losses of the next generation DH based on the constructed Simulink model. Results show that lower distribution temperature and advanced insulation technology greatly reduce network heat losses. Also, the network heat loss can be further minimized by a reduction of heat demand in buildings.

  5. Overview of Heat Addition and Efficiency Predictions for an Advanced Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Wilson, Scott D.; Reid, Terry; Schifer, Nicholas; Briggs, Maxwell

    2011-01-01

    Past methods of predicting net heat input needed to be validated. Validation effort pursued with several paths including improving model inputs, using test hardware to provide validation data, and validating high fidelity models. Validation test hardware provided direct measurement of net heat input for comparison to predicted values. Predicted value of net heat input was 1.7 percent less than measured value and initial calculations of measurement uncertainty were 2.1 percent (under review). Lessons learned during validation effort were incorporated into convertor modeling approach which improved predictions of convertor efficiency.

  6. Increasing of Urban Radiation due to Climate Change and Reduction Strategy using Vegetation

    NASA Astrophysics Data System (ADS)

    Park, C.; Lee, D.; Heo, H. K.; Ahn, S.

    2017-12-01

    Urban Heat Island (UHI) which means urban air temperature is higher than suburban area is one of the most important environmental issues in Urban. High density of buildings and high ratio of impervious surfaces increases the radiation fluxes in urban canopy. Furthermore, climate change is expected to make UHI even more seriously in the future. Increased irradiation and air temperature cause high amount of short wave and long wave radiation, respectively. This increases net radiation negatively affects heat condition of pedestrian. UHI threatens citizen's health by increasing violence and heat related diseases. For this reason, understanding how much urban radiation will increase in the future, and exploring radiation reduction strategies is important for reducing UHI. In this research, we aim to reveal how the radiation flux in the urban canyon will change as the climate change and determine how much of urban vegetation will be needed to cover this degradation. The study area is a commercial district in Seoul where highly populated area. Due to the high density of buildings and lack of urban vegetation, this area has a poor thermal condition in summer. In this research, we simulate the radiation flux on the ground using multi-layer urban canopy model. Unlike conventionally used urban canopy model to simulate radiation transfer using vertically single layer, the multi-layer model we used here, enables to consider the vertical heterogeneous of buildings and urban vegetation. As a result, net radiation of urban ground will be increase 2.1 W/m² in the 2050s and 2.7 W/m² in the 2100s. And to prevent the increase of radiation, it is revealed that the urban vegetation should by increased by 10%. This research will be valuable in establishing greening planning as a strategy to reduce UHI effect.

  7. Efficacy, Outcomes, and Empowerment Evaluation of a School District NET Project, Part III: Theoretical Model.

    ERIC Educational Resources Information Center

    Miller-Whitehead, Marie; Abbott, Gypsy

    The efficacy and outcomes of a U.S. Department of Agriculture Nutrition Education Training (NET) project designed to increase awareness of health risk and wellness factors for grade 9 students were studied. This paper comments on results from a survey of 125 ninth graders about the NET curriculum and results from a study of program impact on…

  8. Efficacy, Outcomes, and Empowerment Evaluation of a School District NET Project, Part II: School and Community Impact. Research Brief.

    ERIC Educational Resources Information Center

    Miller-Whitehead, Marie

    This study addressed assessing the efficacy and outcomes of a U.S. Department of Agriculture Nutrition Education Training (NET) project designed to increase awareness of health risk and wellness factors for grade 9 students. Although this paper reprises results from a survey of 125 ninth graders about the NET curriculum, the focus of this part of…

  9. Feasibility study for retrofitting biogas cogeneration systems to district heating in South Korea.

    PubMed

    Chung, Mo; Park, Hwa-Choon

    2015-08-01

    A feasibility study was performed to assess the technical and economic merits of retrofitting biogas-based cogeneration systems to district heating networks. Three district heating plants were selected as candidates for accommodating heat recovery from nearby waste treatment stations, where a massive amount of biogas can be produced on a regular basis. The scenario involves constructing cogeneration systems in each waste treatment station and producing electricity and heat. The amounts of biogas production for each station are estimated based on the monthly treatment capacities surveyed over the most recent years. Heat produced by the cogeneration system is first consumed on site by the waste treatment system to keep the operating temperature at a proper level. If surplus heat is available, it will be transported to the nearest district heating plant. The year-round operation of the cogeneration system was simulated to estimate the electricity and heat production. We considered cost associated with the installation of the cogeneration system and piping as initial investments. Profits from selling electricity and recovering heat are counted as income, while costs associated with buying biogas are expenses. Simple payback periods of 2-10 years were projected under the current economic conditions of South Korea. We found that most of the proposed scenarios can contribute to both energy savings and environmental protection. © The Author(s) 2015.

  10. "It is about how the net looks": a qualitative study of perceptions and practices related to mosquito net care and repair in two districts in eastern Uganda.

    PubMed

    Scandurra, Leah; Acosta, Angela; Koenker, Hannah; Kibuuka, Daniel Musoke; Harvey, Steven

    2014-12-17

    Prolonging net durability has important implications for reducing both malaria transmission and the frequency of net replacement. Protective behaviour, such as net care and repair, offers promise for improving net integrity and durability. Given the potential cost-savings and public health benefit associated with extending the useful life of long-lasting insecticidal nets (LLINs), prevention and mitigation of damage will become ever more critical to ensuring adequate net coverage at the population level. A qualitative assessment was conducted in two districts in central eastern Uganda in September 2013. Data on household net care and repair behaviour, attitudes and practices were collected from 30 respondents through in-depth interviews (IDIs), observations, photos, and video to gather an in-depth understanding of these behaviours. Net damage was common and the most cited causes were children and rodents. Responses revealed strong social norms about net cleanliness and aesthetics, and strong expectations that others should care for and repair their own nets. Respondents were receptive and able to repair nets, though longer-term repair methods, such as sewing and patching, were not as commonly reported or observed. Self-reported behaviour was not always consistent with observed or demonstrated behaviour, revealing potential misconceptions and the need for clear and consistent net care and repair messaging. Respondents considered both aesthetics and malaria protection important when deciding whether, when, and how to care for and repair nets. BCC should continue to emphasize the importance of maintaining net integrity for malaria prevention purposes as well as for maintaining aesthetic appeal. Additional research is needed, particularly surrounding washing, drying, daily storage routines, and gender roles in care and repair, in order to understand the complexity of these behaviours, and refine existing or develop new behaviour change communication (BCC) messages for net care and repair.

  11. Ground Source Geothermal District Heating and Cooling System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowe, James William

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reducemore » worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx« less

  12. Propulsion and Power Rapid Response Research and Development Support. Delivery Order 0042: Demonstration and Evaluation of Fischer-Tropsch Research Fuels for the DoD Assured Fuels Program

    DTIC Science & Technology

    2006-12-01

    7 Figure 3.1-3. Net Heat of Combustion ...No. 1 Aromatic Carbon, max ASTM D-5292 Mol % < 0.5 Sulfur, Total, Max ASTM D-5453 ppm 1 Cetane Index ASTM D-976 Report Net Heat of Combustion , min ASTM...12 /2 00 6 8/ 19 /2 00 6 8/ 26 /2 00 6 9/ 2/ 20 06 8 Figure 3.1-3. Net Heat of Combustion Trend Figure 3.1-4. Freezing Point Trend Net

  13. Effect of recycling activities on the heating value of solid waste: case study of the Greater Vancouver Regional District (Metro Vancouver).

    PubMed

    Abedini, Ali R; Atwater, James W; Fu, George Yuzhu

    2012-08-01

    Two main goals of the integrated solid waste management system (ISWMS) of Metro Vancouver (MV) include further recycling of waste and energy recovery via incineration of waste. These two very common goals, however, are not always compatible enough to fit in an ISWMS depending on waste characteristics and details of recycling programs. This study showed that recent recycling activities in MV have negatively affected the net heating value (NHV) of municipal solid waste (MSW) in this regional district. Results show that meeting MV's goal for additional recycling of MSW by 2015 will further reduce the NHV of waste, if additional recycling activities are solely focused on more extensive recycling of packaging materials (e.g. paper and plastic). It is concluded that 50% additional recycling of paper and plastic in MV will increase the overall recycling rate to 70% (as targeted by the MV for 2015) and result in more than 8% reduction in NHV of MSW. This reduction translates to up to 2.3 million Canadian dollar (CAD$) less revenue at a potential waste-to-energy (WTE) plant with 500 000 tonnes year(-1) capacity. Properly designed recycling programmes, however, can make this functional element of ISWMS compatible with green goals of energy recovery from waste. Herein an explanation of how communities can increase their recycling activities without affecting the feasibility of potential WTE projects is presented.

  14. Exploring the long-term balance between net precipitation and net groundwater exchange in Florida seepage lakes

    USGS Publications Warehouse

    Lee, Terrie M.; Sacks, Laura A.; Swancar, Amy

    2014-01-01

    The long-term balance between net precipitation and net groundwater exchange that maintains thousands of seepage lakes in Florida’s karst terrain is explored at a representative lake basin and then regionally for the State’s peninsular lake district. The 15-year water budget of Lake Starr includes El Niño Southern Oscillation (ENSO)-related extremes in rainfall, and provides the longest record of Bowen ratio energy-budget (BREB) lake evaporation and lake-groundwater exchanges in the southeastern United States. Negative net precipitation averaging -25 cm/yr at Lake Starr overturns the previously-held conclusion that lakes in this region receive surplus net precipitation. Net groundwater exchange with the lake was positive on average but too small to balance the net precipitation deficit. Groundwater pumping effects and surface-water withdrawals from the lake widened the imbalance. Satellite-based regional estimates of potential evapotranspiration at five large lakes in peninsular Florida compared well with basin-scale evaporation measurements from seven open-water sites that used BREB methods. The regional average lake evaporation estimated for Lake Starr during 1996-2011 was within 5 percent of its measured average, and regional net precipitation agreed within 10 percent. Regional net precipitation to lakes was negative throughout central peninsular Florida and the net precipitation deficit increased by about 20 cm from north to south. Results indicate that seepage lakes farther south on the peninsula receive greater net groundwater inflow than northern lakes and imply that northern lakes are in comparatively leakier hydrogeologic settings. Findings reveal the peninsular lake district to be more vulnerable than was previously realized to drier climate, surface-water withdrawals from lakes, and groundwater pumping effects.

  15. War Comes to Bala Morghab: A Tragedy of Policy and Action in Three Acts

    DTIC Science & Technology

    2011-12-01

    real shower in December—a full 5 months after operations had commenced. The North Atlantic Treaty Organization (NATO) side of the FOB improved...Security Assistance Force (ISAF), Stability Operations Integration Cell ( SOIC ), “Murghab District, Badghis District Narrative Assessment, 5 May 2010...available at <http://publicintelligence. net/ufouo-stability-operations-information-center- soic -murghab-district-assessment/>. 3 Ibid. 4 Most facts

  16. Evaluation of Advanced Stirling Convertor Net Heat Input Correlation Methods Using a Thermal Standard

    NASA Technical Reports Server (NTRS)

    Briggs, Maxwell H.; Schifer, Nicholas A.

    2012-01-01

    The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. In an effort to improve net heat input predictions, numerous tasks have been performed which provided a more accurate value for net heat input into the ASCs, including testing validation hardware, known as the Thermal Standard, to provide a direct comparison to numerical and empirical models used to predict convertor net heat input. This validation hardware provided a comparison for scrutinizing and improving empirical correlations and numerical models of ASC-E2 net heat input. This hardware simulated the characteristics of an ASC-E2 convertor in both an operating and non-operating mode. This paper describes the Thermal Standard testing and the conclusions of the validation effort applied to the empirical correlation methods used by the Radioisotope Power System (RPS) team at NASA Glenn.

  17. Effectiveness of the Home Based Life Saving Skills training by community health workers on knowledge of danger signs, birth preparedness, complication readiness and facility delivery, among women in Rural Tanzania.

    PubMed

    August, Furaha; Pembe, Andrea B; Mpembeni, Rose; Axemo, Pia; Darj, Elisabeth

    2016-06-02

    In spite of government efforts, maternal mortality in Tanzania is currently at more than 400 per 100,000 live births. Community-based interventions that encourage safe motherhood and improved health-seeking behaviour through acquiring knowledge on the danger signs and improving birth preparedness, and, ultimately, reduce maternal mortality, have been initiated in different parts of low-income countries. Our aim was to evaluate if the Home Based Life Saving Skills education by community health workers would improve knowledge of danger signs, birth preparedness and complication readiness and facility-based deliveries in a rural community in Tanzania. A quasi-experimental study design was used to evaluate the effectiveness of Home Based Life Saving Skills education to pregnant women and their families through a community intervention. An intervention district received training with routine care. A comparison district continued to receive routine antenatal care. A structured household questionnaire was used in order to gather information from women who had delivered a child within the last two years before the intervention. This questionnaire was used in both the intervention and comparison districts before and after the intervention. The net intervention effect was estimated using the difference between the differences in the intervention and control districts at baseline and endline. A total of 1,584 and 1,486 women were interviewed at pre-intervention and post intervention, respectively. We observed significant improvement of knowledge of three or more danger signs during pregnancy (15.2 % vs. 48.1 %) with a net intervention effect of 29.0 % (95 % CI: 12.8-36.2; p < .0001) compared to the comparison district. There was significant effect on the knowledge of three or more danger signs during childbirth (15.3 % vs. 43.1 %) with a net intervention effect of 18.3 % (95 % CI: 11.4-25.2; p < .0001) and postpartum for those mentioning three or more of the signs (8.8 % vs. 19.8 %) with net effect of 9.4 % (95 % CI: 6.4-15.7; p < .0001). Birth preparedness practice improved for those who made more than three actions (20.8 vs. 35.3 %) with a net intervention effect of 10.3 % (95 % CI: 10.3-20.3; p < .0001) between the intervention and control district at pre-intervention and post intervention. Utilisation of antenatal care with four visits improved significantly (43.4 vs. 67.8 %) with net effect of 25.3 % (95 % CI: 16.9-33.2; p < .0001), use of facility delivery improved in the intervention area (75.6 vs. 90.2 %; p = 0.0002) but there was no significant net effect 11.5 % (95 % CI: -5.1-39.6; p = 0.123) compared to comparison district. This study shows that a community-based intervention employing community health workers as teachers in delivering Home Based Life Saving Skills program to pregnant women and their families improved their knowledge of danger signs during pregnancy, childbirth and postpartum, preparedness for childbirth and increased deliveries at health facilities which employ skilled health workers in this rural community.

  18. Taking knowledge for health the extra mile: participatory evaluation of a mobile phone intervention for community health workers in Malawi

    PubMed Central

    Campbell, Natalie; Schiffer, Eva; Buxbaum, Ann; McLean, Elizabeth; Perry, Cary; Sullivan, Tara M

    2014-01-01

    In Malawi, where the majority of the population resides in rural areas, community health workers (CHWs) are the first, and often only, providers of health services. An assessment of health information needs, however, found that these frontline workers often lacked essential health information. A pilot project, implemented in 2 rural districts of Malawi between 2010 and 2011, introduced a mobile phone system to strengthen knowledge exchange within networks of CHWs and district staff. To evaluate the mobile phone intervention, a participatory evaluation method called Net-Map was used, an approach built on traditional social network analysis. Together, CHWs and district personnel discussed information needs and gaps and the roles of different actors in their information networks. They then used drawings and 3-dimensional objects to create baseline and endline maps showing the linkages and levels of influence among members of the information network. Net-Map provided them with powerful evidence of differences before and after the mobile phone initiative. At baseline, CHWs were not mentioned as actors in the information network, while at endline they were seen to have significant connections with colleagues, beneficiaries, supervisors, and district health facilities, as both recipients and providers of information. Focus groups with CHWs complemented the Net-Map findings with reports of increased self-confidence and greater trust by their communities. These qualitative results were bolstered by surveys that showed decreases in stockouts of essential medicines, lower communication costs, wider service coverage, and more efficient referrals. As an innovative, participatory form of social network analysis, Net-Map yielded important visual, quantitative, and qualitative information at reasonable cost. PMID:25276560

  19. Taking knowledge for health the extra mile: participatory evaluation of a mobile phone intervention for community health workers in Malawi.

    PubMed

    Campbell, Natalie; Schiffer, Eva; Buxbaum, Ann; McLean, Elizabeth; Perry, Cary; Sullivan, Tara M

    2014-02-01

    In Malawi, where the majority of the population resides in rural areas, community health workers (CHWs) are the first, and often only, providers of health services. An assessment of health information needs, however, found that these frontline workers often lacked essential health information. A pilot project, implemented in 2 rural districts of Malawi between 2010 and 2011, introduced a mobile phone system to strengthen knowledge exchange within networks of CHWs and district staff. To evaluate the mobile phone intervention, a participatory evaluation method called Net-Map was used, an approach built on traditional social network analysis. Together, CHWs and district personnel discussed information needs and gaps and the roles of different actors in their information networks. They then used drawings and 3-dimensional objects to create baseline and endline maps showing the linkages and levels of influence among members of the information network. Net-Map provided them with powerful evidence of differences before and after the mobile phone initiative. At baseline, CHWs were not mentioned as actors in the information network, while at endline they were seen to have significant connections with colleagues, beneficiaries, supervisors, and district health facilities, as both recipients and providers of information. Focus groups with CHWs complemented the Net-Map findings with reports of increased self-confidence and greater trust by their communities. These qualitative results were bolstered by surveys that showed decreases in stockouts of essential medicines, lower communication costs, wider service coverage, and more efficient referrals. As an innovative, participatory form of social network analysis, Net-Map yielded important visual, quantitative, and qualitative information at reasonable cost.

  20. Effectiveness of a new long-lasting insecticidal nets delivery model in two rural districts of Mozambique: a before-after study.

    PubMed

    Arroz, Jorge A H; Candrinho, Baltazar; Mendis, Chandana; Varela, Pablo; Pinto, João; Martins, Maria do Rosário O

    2018-02-05

    In 2015, Mozambique piloted a new model of long-lasting insecticidal nets (LLINs) delivery in a campaign. The new delivery model was used in two rural districts were, and two others were considered as control, maintaining the old delivery model. The aim of this study is to compare the coverage of ownership and use of LLINs in intervention and control districts in Mozambique. A before-after design with control group was carried out 6 months after LLINs distribution. Using systematic probabilistic sampling, 1547 households were surveyed by means of a questionnaire. To find associations between the district categories (intervention and control) and the main outcomes of the study (LLIN ownership, use, and universal coverage achievement), odds ratio (OR) and respective confidence intervals were calculated. Of the 760 households surveyed in the intervention districts, 98.8% had at least one LLIN; of the 787 households surveyed in the control districts, 89.6% had at least one LLIN [OR: 9.7, 95% (CI 4.84-19.46)]. Around 95 and 87% of households owning at least one LLIN reported having slept under the LLIN the previous night in the intervention and control districts, respectively [OR: 3.2; 95% (CI 2.12-4.69)]. Seventy-one percent of the households surveyed achieved universal coverage in the intervention districts against 59.6% in the control districts [OR: 1.6; 95% (CI 1.33-2.03)]. The universal coverage campaign piloted with the new delivery model has increased LLINs ownership, use, and progression for reaching universal coverage targets in the community.

  1. Basin view geothermal heating district, Klamath Falls, Oregon. Conceptual design and economic-feasibility study report

    NASA Astrophysics Data System (ADS)

    1981-07-01

    The findings of a feasibility study performed for Basin View Heating District in Klamath Falls, Oregon are reported. The physical, economic, and political feasibility of establishing a geothermal heating district to provide space heat to housing units in the Basin View Development of Klamath Falls are determined. Of the several systems considered, all are physically feasible. The project is politically feasible if the owner complies with governmental requirements. Economic feasibility is based on considerations of money value rates, tax rates and expected rates of return, which are dependent on government and money markets. For analysis a money value rate of 21% and an owner's marginal tax rate of 35% were adopted.

  2. Analysis and comparison of methods for the preparation of domestic hot water from district heating system, selected renewable and non-renewable sources in low-energy buildings

    NASA Astrophysics Data System (ADS)

    Knapik, Maciej

    2018-02-01

    The article presents an economic analysis and comparison of selected (district heating, natural gas, heat pump with renewable energy sources) methods for the preparation of domestic hot water in a building with low energy demand. In buildings of this type increased demand of energy for domestic hot water preparation in relation to the total energy demand can be observed. As a result, the proposed solutions allow to further lower energy demand by using the renewable energy sources. This article presents the results of numerical analysis and calculations performed mainly in MATLAB software, based on typical meteorological years. The results showed that system with heat pump and renewable energy sources Is comparable with district heating system.

  3. Analysis and research on thermal infrared properties and adaptability of the camouflage net

    NASA Astrophysics Data System (ADS)

    Cui, Guangzhen; Hu, Jianghua; Jian, Chaochao; Yang, Juntang

    2016-10-01

    As camouflage equipment, camouflage net which covers or obstruct the enemy reconnaissance and attack, have the compatibility such as optics, infrared, radar wave band performance. To improve the adaptive between the camouflage net with background in infrared wavelengths, the heat shield and heat integration requirements on the surface of the camouflage net was analyzed. The condition that satisfied the heat shield was when the average thermal infrared transmittance was less than 25.38% on camouflage screen surface. Studies have shown that camouflage nets and the background field fused together when infrared radiation temperature difference control is within the scope of ± 4K . Experiment on temperature contrast was tested in situ background, thermal camouflage spots and camouflage net with sponge material, the infrared heat maps was recorded in the period of experiment through the thermal imager. Results showed that the thermal inertia of camouflage net was markedly lower than the background and the exposed signs were obvious. It was difficult to reach camouflage thermal infrared fusion requirements by relying on camouflage spot emissivity, but sponge which mix with polymer resin can reduce target significance in the context of mottled and realize the fusion effect.

  4. World Energy Projection System Plus Model Documentation: District Heat Module

    EIA Publications

    2017-01-01

    This report documents the objectives, analytical approach and development of the World Energy Projection System Plus (WEPS ) District Heat Model. It also catalogues and describes critical assumptions, computational methodology, parameter estimation techniques, and model source code.

  5. Risk perception of heat waves and its spatial variation in Nanjing, China

    NASA Astrophysics Data System (ADS)

    Huang, Lei; Yang, Qianqi; Li, Jie; Chen, Jin; He, Ruoying; Zhang, Can; Chen, Kai; Dong, Steven Guanpeng; Liu, Yang

    2018-05-01

    The intensity, frequency, and duration of heat waves are expected to increase with climate change. In this study, we found a significant difference of public perceived effects of heat waves and trust in government among urban, suburban, and rural districts. Rural residents had a significant higher effect perception than urbanites and also showed stronger willingness to have medical insurance or regular physical examinations. Meanwhile, suburban residents had the lowest trust perception in government among these three districts, which may be due to suburban districts' unique social structure and complex social issues. Besides, we assessed the relationship between the factor effect and demographic variables. The results showed that urban respondents' effect perception was significantly related to heat wave experiences. Suburban respondents' effect perception was significantly related to age, income, and heat wave experiences. And rural respondents' effect perception was significantly related to income and chronic diseases. Based on our results, much more attention needs to be paid to rural districts. The government should strengthen infrastructure construction such as cooling centers, improve emergency response plans and mechanisms, and increase reserves of emergency supplies in rural districts. Also, targeted risk communication is of the equal importance to aid the policy-makers improving the relationship with the public and regaining the public's trust and support.

  6. Risk perception of heat waves and its spatial variation in Nanjing, China.

    PubMed

    Huang, Lei; Yang, Qianqi; Li, Jie; Chen, Jin; He, Ruoying; Zhang, Can; Chen, Kai; Dong, Steven Guanpeng; Liu, Yang

    2018-05-01

    The intensity, frequency, and duration of heat waves are expected to increase with climate change. In this study, we found a significant difference of public perceived effects of heat waves and trust in government among urban, suburban, and rural districts. Rural residents had a significant higher effect perception than urbanites and also showed stronger willingness to have medical insurance or regular physical examinations. Meanwhile, suburban residents had the lowest trust perception in government among these three districts, which may be due to suburban districts' unique social structure and complex social issues. Besides, we assessed the relationship between the factor effect and demographic variables. The results showed that urban respondents' effect perception was significantly related to heat wave experiences. Suburban respondents' effect perception was significantly related to age, income, and heat wave experiences. And rural respondents' effect perception was significantly related to income and chronic diseases. Based on our results, much more attention needs to be paid to rural districts. The government should strengthen infrastructure construction such as cooling centers, improve emergency response plans and mechanisms, and increase reserves of emergency supplies in rural districts. Also, targeted risk communication is of the equal importance to aid the policy-makers improving the relationship with the public and regaining the public's trust and support.

  7. Risk perception of heat waves and its spatial variation in Nanjing, China

    NASA Astrophysics Data System (ADS)

    Huang, Lei; Yang, Qianqi; Li, Jie; Chen, Jin; He, Ruoying; Zhang, Can; Chen, Kai; Dong, Steven Guanpeng; Liu, Yang

    2017-12-01

    The intensity, frequency, and duration of heat waves are expected to increase with climate change. In this study, we found a significant difference of public perceived effects of heat waves and trust in government among urban, suburban, and rural districts. Rural residents had a significant higher effect perception than urbanites and also showed stronger willingness to have medical insurance or regular physical examinations. Meanwhile, suburban residents had the lowest trust perception in government among these three districts, which may be due to suburban districts' unique social structure and complex social issues. Besides, we assessed the relationship between the factor effect and demographic variables. The results showed that urban respondents' effect perception was significantly related to heat wave experiences. Suburban respondents' effect perception was significantly related to age, income, and heat wave experiences. And rural respondents' effect perception was significantly related to income and chronic diseases. Based on our results, much more attention needs to be paid to rural districts. The government should strengthen infrastructure construction such as cooling centers, improve emergency response plans and mechanisms, and increase reserves of emergency supplies in rural districts. Also, targeted risk communication is of the equal importance to aid the policy-makers improving the relationship with the public and regaining the public's trust and support.

  8. Tidal and atmospheric forcing of the upper ocean in the Gulf of California. 2: Surface heat flux

    NASA Technical Reports Server (NTRS)

    Paden, Cynthia A.; Winant, Clinton D.; Abbott, Mark R.

    1993-01-01

    Satellite infrared imagery and coastal meteorological data for March 1984 through February 1985 are used to estimate the net annual surface heat flux for the northern Gulf of California. The average annual surface heat flux for the area north of Guaymas and Santa Rosalia is estimated to be +74 W/sq m for the 1984-1985 time period. This is comparable to the +20-50 W/sq m previously obtained from heat and freshwater transport estimates made with hydrographic surveys from different years and months. The spatial distribution of the net surface heat flux shows a net gain of heat over the whole northern gulf. Except for a local maximum near San Esteban Island, the largest heat gain (+110-120 W/sq m) occurs in the Ballenas and Salsipuedes channels, where strong tidal mixing produces anomalously cold sea surface temperatures (SSTs) over much of the year. The lowest heat gain occurs in the Guayamas Basin (+40-50 W/sq m), where SSTs are consistently warmer. In the relatively shallow northern basin the net surface heat flux is farily uniform, with a net annual gain of approxmately +70 W/sq m. A local minimum in heat gain (approximately +60 W/sq m) is observed over the shelf in the northwest, where spring and summer surface temperatures are particularly high. A similar minimum in heat gain over the shelf was observed in a separate study in which historical SSTs and 7 years (1979-1986) of meteorological data from Puerto Penasco were used to estimate the net surface heat flux for the northern basin. In that study, however, the heat fluxes were higher, with a gain of +100 W/sq m over the shelf and +114 W/sq m in the northern basin. These larger values are directly attributable to the higher humidities in the 1979-1986 study compared to the 1984-1985 satellite study. High humidities reduce evaporation and the associated latent heat loss, promoting a net annual heat gain. In the norther Gulf of California, however, tidal mixing appears to play a key role in the observed gain of heat. Deep mixing in the island region produces a persistent pool of cold water which is mixed horizontally by the large-scale circulation, lowering surface temperatures over most of the northern gulf. These cold SSTs decrease evaporation by reducing the saturation vapor pressure of the overlying air. As a result, heat loss is substantially reduced, even when humidities are low. By removing heat from the surface, tidal mixing alters the time scale of air-sea interaction and reduces or possibly even inhibits the formation of deep water masses via convection.

  9. Green Space and Deaths Attributable to the Urban Heat Island Effect in Ho Chi Minh City.

    PubMed

    Dang, Tran Ngoc; Van, Doan Quang; Kusaka, Hiroyuki; Seposo, Xerxes T; Honda, Yasushi

    2018-04-01

    To quantify heat-related deaths in Ho Chi Minh City, Vietnam, caused by the urban heat island (UHI) and explore factors that may alleviate the impact of UHIs. We estimated district-specific meteorological conditions from 2010 to 2013 using the dynamic downscaling model and calculated the attributable fraction and number of mortalities resulting from the total, extreme, and mild heat in each district. The difference in attributable fraction of total heat between the central and outer districts was classified as the attributable fraction resulting from the UHI. The association among attributable fraction, attributable number with a green space, population density, and budget revenue of each district was then explored. The temperature-mortality relationship between the central and outer areas was almost identical. The attributable fraction resulting from the UHI was 0.42%, which was contributed by the difference in temperature distribution between the 2 areas. Every 1-square-kilometer increase in green space per 1000 people can prevent 7.4 deaths caused by heat. Green space can alleviate the impacts of UHIs, although future studies conducting a heath economic evaluation of tree planting are warranted.

  10. Green Space and Deaths Attributable to the Urban Heat Island Effect in Ho Chi Minh City

    PubMed Central

    Van, Doan Quang; Kusaka, Hiroyuki; Seposo, Xerxes T.; Honda, Yasushi

    2018-01-01

    Objectives. To quantify heat-related deaths in Ho Chi Minh City, Vietnam, caused by the urban heat island (UHI) and explore factors that may alleviate the impact of UHIs. Methods. We estimated district-specific meteorological conditions from 2010 to 2013 using the dynamic downscaling model and calculated the attributable fraction and number of mortalities resulting from the total, extreme, and mild heat in each district. The difference in attributable fraction of total heat between the central and outer districts was classified as the attributable fraction resulting from the UHI. The association among attributable fraction, attributable number with a green space, population density, and budget revenue of each district was then explored. Results. The temperature–mortality relationship between the central and outer areas was almost identical. The attributable fraction resulting from the UHI was 0.42%, which was contributed by the difference in temperature distribution between the 2 areas. Every 1-square-kilometer increase in green space per 1000 people can prevent 7.4 deaths caused by heat. Conclusions. Green space can alleviate the impacts of UHIs, although future studies conducting a heath economic evaluation of tree planting are warranted. PMID:29072938

  11. Design and optimization of geothermal power generation, heating, and cooling

    NASA Astrophysics Data System (ADS)

    Kanoglu, Mehmet

    Most of the world's geothermal power plants have been built in 1970s and 1980s following 1973 oil crisis. Urgency to generate electricity from alternative energy sources and the fact that geothermal energy was essentially free adversely affected careful designs of plants which would maximize their performance for a given geothermal resource. There are, however, tremendous potentials to improve performance of many existing geothermal power plants by retrofitting, optimizing the operating conditions, re-selecting the most appropriate binary fluid in binary plants, and considering cogeneration such as a district heating and/or cooling system or a system to preheat water entering boilers in industrial facilities. In this dissertation, some representative geothermal resources and existing geothermal power plants in Nevada are investigated to show these potentials. Economic analysis of a typical geothermal resource shows that geothermal heating and cooling may generate up to 3 times as much revenue as power generation alone. A district heating/cooling system is designed for its incorporation into an existing 27 MW air-cooled binary geothermal power plant. The system as designed has the capability to meet the entire heating needs of an industrial park as well as 40% of its cooling needs, generating potential revenues of $14,040,000 per year. A study of the power plant shows that evaporative cooling can increase the power output by up to 29% in summer by decreasing the condenser temperature. The power output of the plant can be increased by 2.8 percent by optimizing the maximum pressure in the cycle. Also, replacing the existing working fluid isobutane by butane, R-114, isopentane, and pentane can increase the power output by up to 2.5 percent. Investigation of some well-known geothermal power generation technologies as alternatives to an existing 12.8 MW single-flash geothermal power plant shows that double-flash, binary, and combined flash/binary designs can increase the net power output by up to 31 percent, 35 percent, and 54 percent, respectively, at optimum operating conditions. An economic comparison of these designs appears to favor the combined flash/binary design, followed by the double-flash design.

  12. District heating and cooling feasibility study, Dunkirk, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The objective of this project is to perform a preliminary investigation of the technical and economic feasibility of implementing a district heating and cooling (DHC) system in the City of Dunkirk, New York. The study was conducted by first defining a heating and cooling (HC) load service area. Then, questionnaires were sent to prospective DHC customers. After reviewing the owners responses, large consumers of energy were interviewed for more detail of their HC systems, including site visits, to determine possibilities of retrofitting their systems to district heating and cooling. Peak HC loads for the buildings were estimated by Burns andmore » Roe's in-house computer programs. Based on the peak loads, certain customers were determined for suitability as anchor customers. Various options using cogeneration were investigated for possible HC sources. Equipment for HC sources and HC loads were sized and their associated costs estimated. Finally, economic analyses were performed. The conclusion is that it is technically and economically feasible to implement a district heating and cooling system in the City of Dunkirk. 14 figs., 15 tabs.« less

  13. Steamtown District Heating and Cooling Project, Scranton, Pennsylvania. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This report summarizes the activities of a study intended to examine the feasibility of a district heating and cooling alternative for the Steamtown National Historic Site in Scranton, PA. The objective of the study was to investigate the import of steam from the existing district heating system in Scranton which is operated by the Community Central Energy Corporation and through the use of modern technology provide hot and chilled water to Steamtown for its internal heating and cooling requirements. Such a project would benefit Steamtown by introducing a clean technology, eliminating on-site fuel use, avoiding first costs for central heatingmore » and cooling plants and reducing operation and maintenance expenditures. For operators of the existing district heating system, this project represents an opportunity to expand their customer base and demonstrate new technologies. The study was conducted by Joseph Technology Corporation, Inc. and performed for the Community Central Energy Corporation through a grant by the US Department of Energy. Steamtown was represented by the National Park Service, the developers of the site.« less

  14. Thermal Transients in District Heating Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chertkov, Michael; Novitsky, Nikolai N.

    Heat fluxes in a district heating pipeline systems need to be controlled on the scale from minutes to an hour to adjust to evolving demand. There are two principal ways to control the heat flux - keep temperature fixed but adjust velocity of the carrier (typically water) or keep the velocity flow steady but then adjust temperature at the heat producing source (heat plant). Here, we study the latter scenario, commonly used for operations in Russia and Nordic countries, and analyze dynamics of the heat front as it propagates through the system. Steady velocity flows in the district heating pipelinesmore » are typically turbulent and incompressible. Changes in the heat, on either consumption or production sides, lead to slow transients which last from tens of minutes to hours. We classify relevant physical phenomena in a single pipe, e.g. turbulent spread of the turbulent front. We then explain how to describe dynamics of temperature and heat flux evolution over a network efficiently and illustrate the network solution on a simple example involving one producer and one consumer of heat connected by “hot” and “cold” pipes. We conclude the manuscript motivating future research directions.« less

  15. Thermal Transients in District Heating Systems

    DOE PAGES

    Chertkov, Michael; Novitsky, Nikolai N.

    2018-01-18

    Heat fluxes in a district heating pipeline systems need to be controlled on the scale from minutes to an hour to adjust to evolving demand. There are two principal ways to control the heat flux - keep temperature fixed but adjust velocity of the carrier (typically water) or keep the velocity flow steady but then adjust temperature at the heat producing source (heat plant). Here, we study the latter scenario, commonly used for operations in Russia and Nordic countries, and analyze dynamics of the heat front as it propagates through the system. Steady velocity flows in the district heating pipelinesmore » are typically turbulent and incompressible. Changes in the heat, on either consumption or production sides, lead to slow transients which last from tens of minutes to hours. We classify relevant physical phenomena in a single pipe, e.g. turbulent spread of the turbulent front. We then explain how to describe dynamics of temperature and heat flux evolution over a network efficiently and illustrate the network solution on a simple example involving one producer and one consumer of heat connected by “hot” and “cold” pipes. We conclude the manuscript motivating future research directions.« less

  16. Alternative Methods in the Evaluation of School District Cash Management Programs.

    ERIC Educational Resources Information Center

    Dembowski, Frederick L.

    1980-01-01

    Empirically evaluates three measures of effectiveness of school district cash management: the rate of return method in common use and two new measures--efficiency rating and Net Present Value (NPV). The NPV approach allows examination of efficiency and provides a framework for evaluating other areas of educational policy. (Author/IRT)

  17. Analysis of the surface heat balance over the world ocean

    NASA Technical Reports Server (NTRS)

    Esbenson, S. K.

    1981-01-01

    The net surface heat fluxes over the global ocean for all calendar months were evaluated. To obtain a formula in the form Qs = Q2(T*A - Ts), where Qs is the net surface heat flux, Ts is the sea surface temperature, T*A is the apparent atmospheric equilibrium temperature, and Q2 is the proportionality constant. Here T*A and Q2, derived from the original heat flux formulas, are functions of the surface meteorological parameters (e.g., surface wind speed, air temperature, dew point, etc.) and the surface radiation parameters. This formulation of the net surface heat flux together with climatological atmospheric parameters provides a realistic and computationally efficient upper boundary condition for oceanic climate modeling.

  18. The influence of using heat storage with PCM on inlet and outlet temperatures in substation in DHS

    NASA Astrophysics Data System (ADS)

    Nogaj, Kinga; Turski, Michał; Sekret, Robert

    2017-11-01

    The main objective of this article is to indicate the direction of development of new generation heating systems that use phase change materials, and the important criteria needed when choosing a phase change material. The work contains a detailed classification of materials using the latent heat of organic and inorganic PCM. This references the technical possibilities of existing heat storage technologies. A specific objective was adopted to determine the effect of using heat storage with PCM on inlet and outlet temperatures in substation in district heating systems. The scope of the study included determining the parameters of the heat distribution network as a function of an outdoor air temperature within the range of -20°C to + 12°C. The object of analysis was chosen to be the heating system parameters: supply 120°C and return 60°C. It is located on the surface of 160km2, and supplies heat to 240,000 residents. The total length of the district heating network is 170 km. Based on the study, it was found that the most advantageous material that accumulates heat depends on the return temperature in the heating network. For the above analyzed case, the return temperature was in the range of 46°C to 57°C. The analysis showed that the most preferred materials using heat of phase change, have possible applications in heating networks and received a return temperature including salt hydrates, such as MgSO4·7H2O and Na2S2O3·5H2. The introduction of stored heat for the district heating system with the phase change material in the form of salt hydrates, allows the return temperature in the district heating to remain at temperatures compatible with the adopted regulatory table for temperatures outside the standard heating season.

  19. Integration of Decentralized Thermal Storages Within District Heating (DH) Networks

    NASA Astrophysics Data System (ADS)

    Schuchardt, Georg K.

    2016-12-01

    Thermal Storages and Thermal Accumulators are an important component within District Heating (DH) systems, adding flexibility and offering additional business opportunities for these systems. Furthermore, these components have a major impact on the energy and exergy efficiency as well as the heat losses of the heat distribution system. Especially the integration of Thermal Storages within ill-conditioned parts of the overall DH system enhances the efficiency of the heat distribution. Regarding an illustrative and simplified example for a DH system, the interactions of different heat storage concepts (centralized and decentralized) and the heat losses, energy and exergy efficiencies will be examined by considering the thermal state of the heat distribution network.

  20. Determinants of malaria infection in Dembia district, Northwest Ethiopia: a case-control study.

    PubMed

    Agegnehu, Fisseha; Shimeka, Alemayehu; Berihun, Firnus; Tamir, Melkamu

    2018-04-11

    Despite the progress in reducing malaria infections and related deaths, the disease remains a major global public health problem. The problem is among the top five leading causes of outpatient visits in Dembia district of the northwest Ethiopia. Therefore, this study aimed to assess the determinants of malaria infections in the district. An institution-based case-control study was conducted in Dembia district from October to November 2016. Out of the ten health centers in the district, four were randomly selected for the study in which 370 participants (185 cases and 185 controls) were enrolled. Data were collected using a pretested structured questionnaire. Factors associated with malaria infections were determined using logistic regression analysis. Odds ratio with 95% CI was used as a measure of association, and variables with a p-value of ≤0.05 were considered as statistically significant. The median age of all participants was 26 years, while that of cases and controls was 22 and 30 with a range of 1 to 80 and 2 to 71, respectively. In the multivariable logistic regression, over 15 years of age adjusted odds ratio(AOR) and confidence interval (CI) of (AOR = 18; 95% CI: 2.1, 161.5), being male (AOR = 2.2; 95% CI: 1.2, 3.9), outdoor activities at night (AOR = 5.7; 95% CI: 2.5, 12.7), bed net sharing (AOR = 3.9; 95% CI: 2.0, 7.7), and proximity to stagnant water sources (AOR = 2.7; 95% CI: 1.3, 5.4) were independent predictors. Being in over 15 years of age group, male gender, night time activity, bed net sharing and proximity to stagnant water sources were determinant factors of malaria infection in Dembia district. Additional interventions and strategies which focus on men, outdoor work at night, household net utilization, and nearby stagnant water sources are essential to reduce malaria infections in the area.

  1. 10. Photocopy of heating and electrical blueprint (on file at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of heating and electrical blueprint (on file at La Grande District Office, La Grande, Oregon) USDA Forest Service, 1939 GUARD RESIDENCE - Union Ranger District Compound, Guard Residence, Fronting State Highway 203, at West edge of Union, Union, Union County, OR

  2. Application of service oriented architecture for sensors and actuators in district heating substations.

    PubMed

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-08-21

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation.

  3. Application of Service Oriented Architecture for Sensors and Actuators in District Heating Substations

    PubMed Central

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-01-01

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation. PMID:25196165

  4. Ohio SchoolNet Initiatives: The Role of the Ohio Education Computer Network.

    ERIC Educational Resources Information Center

    Ohio State Legislative Office of Education Oversight, Columbus.

    Ohio's Legislative Office of Education Oversight (LOEO) evaluates education-related activities funded wholly or in part by that state. SchoolNet initiatives seek to increase Ohio K-12 schools' access to computers, networks, and other technology, with a particular emphasis on low-wealth districts. This report addresses the gap between the…

  5. Teaching Russian Via Distance Learning, the EdNet Experience.

    ERIC Educational Resources Information Center

    Zsiray, Stephen W., Jr.; And Others

    In Utah, the statewide distance education network (EdNet) enables students from five rural and suburban high schools to learn Russian and earn college credits. Courses in Russian are offered through a partnership involving the Cache County School District, Utah State University, and the Utah State Office of Education. Classes are taught on one…

  6. Insecticide susceptibility of Phlebotomus argentipes & assessment of vector control in two districts of West Bengal, India.

    PubMed

    Kumar, Vijay; Shankar, Lokesh; Kesari, Shreekant; Bhunia, Gouri Shankar; Dinesh, Diwakar Singh; Mandal, Rakesh; Das, Pradeep

    2015-08-01

    Kala-azar or visceral leishmanisis (VL) is known to be endemic in several States of India including West Bengal (WB). Only meager information is available on the vector dynamics of its vector species, Phlebotomus argentipes particularly in relation to control measure from this State. Hence, a pilot study was undertaken to assess the control strategy and its impact on vector in two endemic districts of WB, India. Two villages each from the two districts, Maldah and Burdwan, were selected for the study. Seasonal variation of sandflies was observed during pre-monsoon, post-monsoon and winter seasons. Susceptibility test of P. argentipes against DDT and bioassay on DDT sprayed wall and on long lasting insecticide nets (LN) Perma Net [®] 2.0 were conducted as per the WHO standard methods. P. argentipes density was high during March to October. Susceptibility status of P. argentipes ranged from 40 to 61.54 per cent. Bioassay test showed 57.89 per cent mortality against LN PermaNet [®] -2.0. and 50 per cent against DDT on wall within 30 min of exposure. Despite the integrated vector management approach, the sandfly population was high in the study area. The reason could be development of resistance in P. argentipes against DDT and low effectiveness of LN PermaNet [®] -2.0. The more pragmatic step will be to conduct large studies to monitor the susceptibility level in P. argentipes against DDT.

  7. Factors associated with the use of mosquito bed nets: results from two cross-sectional household surveys in Zambézia Province, Mozambique.

    PubMed

    Moon, Troy D; Hayes, Caleb B; Blevins, Meridith; Lopez, Melanie L; Green, Ann F; González-Calvo, Lazaro; Olupona, Omo

    2016-04-11

    Malaria remains a major threat to some 3.2 billion persons globally. Malaria contributes heavily to the overall disease burden in Mozambique and is considered endemic. A cornerstone of Mozambique's vector control strategy has been to strive for universal coverage of insecticide-treated nets (ITN). The study is a population-based cross-sectional survey of female heads-of-household in Zambézia Province, Mozambique conducted during August-September, 2010 and April-May, 2014. Analyses accounted for a stratified two-stage cluster sample design. Outcomes of interest included sleeping under a mosquito net during the previous night. Descriptive statistics were calculated for three oversampled districts and for the entire province. Multivariable logistic regression analysis was used to estimate factors associated with both changes over time and increased mosquito bed net usage. Of the 3916 households interviewed in 2010 and 3906 households in 2014, 64.3% were in possession of at least one mosquito bed net. A higher proportion of households in Namacurra (90%) reported possession of a mosquito net, compared to Alto Molócuè (77%) and Morrumbala (34%), respectively in 2014. Of pregnant respondents, 58.6% reported sleeping under a mosquito net the previous night in 2010 compared to 68.4% in 2014. Fifty percent of children 0-59 months slept under a mosquito net the previous night in 2010 compared to 60% in 2014. Factors associated with use of a mosquito net for female head-of-household respondents were higher education, understanding Portuguese, larger household size, having electricity in the household, and larger household monthly income. As travel time to a health facility increased (per 1 h), respondents had 13% lower odds of sleeping under a mosquito net (OR 0.87; 95% CI 0.74-1.01, p = 0.07). Pregnant women in 2014 had a 2.4 times higher odds of sleeping under a bed net if they lived in Namacurra compared to Alto Molócuè (95% CI 0.91-6.32, p = 0.002 for district). Higher maternal education, living in Namacurra, and acquisition of mosquito bed nets were associated with a child 0-59 months reporting sleeping under the net in the previous night in 2014. Intensified focus on the poorest, least educated, and most distant from health services is needed to improve equity of ITN availability and usage. Additionally, while some districts have already surpassed goals in terms of coverage and utilization of ITN, renewed emphasis should be placed on bringing all geographic regions of the province closer to meeting these targets.

  8. Global radiative adjustment after a collapse of the Atlantic meridional overturning circulation

    NASA Astrophysics Data System (ADS)

    Drijfhout, Sybren S.

    2015-10-01

    The transient climate response to a collapse of the Atlantic meridional overturning circulation (AMOC) is analysed from the difference between two ensembles of climate model simulations with ECHAM5/MPI-OM, one with hosing and the other without hosing. The primary effect of the collapse is to redistribute heat over the two hemispheres. However, Northern Hemisphere sea ice increase in response to the AMOC collapse induces a hemisphere-wide cooling, amplified by atmospheric feedbacks, in particular water vapour. The Southern Hemisphere warming is governed by slower processes. After 25 years the global cooling peaks. Thereafter, the response is characterised by a gradual readjustment of global mean temperature. During the AMOC collapse a downward radiation anomaly arises at the top of the atmosphere (TOA), heating the earth's surface. The net downward radiation anomaly at TOA arises from reduced longwave emission by the atmosphere, overcompensating the increased net upward anomalies in shortwave and longwave radiation at the surface. This radiation anomaly is associated with net ocean heat uptake: cooling of the overlying atmosphere results from reduced ocean heat release through the increase of sea-ice cover in the North Atlantic. The change in energy flow arises from the reduction in latent and sensible heat flux, which dominate the surface radiation budget. Similar experiments with a climate model of intermediate complexity reveal a stronger shortwave response that acts to reduce the net downward radiation anomaly at TOA. The net shortwave and longwave radiation anomalies at TOA always decrease during the first 100 years after the AMOC collapse, but in the intermediate complexity model this is associated with a sign change after 90 years when the net radiation anomaly at TOA becomes upward, accompanied by net ocean heat loss. After several hundred years the longwave and shortwave anomalies increase again, while the net residual at TOA remains small. This radiative adjustment is associated with the transition to a colder climate.

  9. Assessment on the ownership and use of mosquito nets in Mozambique.

    PubMed

    Arroz, Jorge Alexandre Harrison; Chirrute, Francisco; Mendis, Chandana; Chande, Marta Honesta; Kollhoff, Veronique

    2016-12-22

    To assess the ownership and use of mosquito nets in 2014, in Mozambique. This observational and cross-sectional study assessed, in February and March 2015, 69 districts (nine of 11 provinces of Mozambique) that have benefited from the mass distribution of mosquito nets. The Lot Quality Assurance Sampling methodology was used. Each locality was denominated supervision area. The Lot Quality Assurance Sampling opts for a minimum of 19 households (in this case, we decided for a minimum of 100 households per district) from each supervision area to assess an indicator (in this case, two indicators were assessed: ownership and use of mosquito nets). Two questions guided the research: a) received a mosquito net; b) used a mosquito net the night before. A total of 6,725 households were assessed. Eighty three percent of them had received mosquito nets in the campaign. Of the 6,232 respondents, 82.0% said they used mosquito nets the night before. The districts of the provinces with low coverage of ownership and use were Tete (69.5% and 60.0%, respectively), Zambezia (79.0% and 60.0%, respectively), and Gaza (81.6% and 70.7%, respectively). The largest coverage of ownership and use were observed in the districts of Nampula (96.7% and 93.8%, respectively) and Niassa (86.0% and 85.4% respectively). In the districts assessed, the progression of ownership and use of mosquito nets is satisfactory. Nampula and Niassa are the only provinces where ownership and use are at desired levels. Avaliar a posse e o uso das redes mosquiteiras no ano de 2014 em Moçambique. Este estudo observacional transversal avaliou, em fevereiro e março de 2015, 68 distritos (nove das 11 províncias de Moçambique) que se beneficiaram da distribuição de redes em massa. Usou-se a metodologia Lot Quality Assurance Sampling. Cada localidade foi designada de área de supervisão. O Lot Quality Assurance Sampling opta por um mínimo de 19 agregados familiares (neste caso decidiu-se um mínimo de 100 agregados familiares por distrito) de cada área de supervisão, a fim de avaliar um indicador (neste caso dois indicadores foram avaliados: posse e uso de redes mosquiteiras). Duas perguntas nortearam a pesquisa: a) recebeu rede; b) usou rede na noite anterior. Foram avaliados 6.725 agregados familiares . Desses, 83,0% tinham recebido redes na campanha. Dos 6.232 inqueridos, 82,0% disseram que usaram na noite anterior. As províncias com distritos com menores coberturas de posse e uso foram Tete (69,5% e 60,0%, respectivamente), Zambézia (79,0% e 60,0%, respectivamente) e Gaza (81,6% e 70,7%, respectivamente). As maiores coberturas de posse e uso foram observadas nos distritos de Nampula (96,7% e 93,8%, respectivamente) e Niassa (86,0% e 85,4%, respectivamente). Nos distritos avaliados, a progressão para a posse e uso de redes mosquiteiras é satisfatória. Nampula e Niassa são as únicas províncias onde a posse e o uso estão em níveis desejados.

  10. Geothermal System Extensions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunnerson, Jon; Pardy, James J.

    This material is based upon work supported by the Department of Energy under Award Number DE-EE0000318. The City of Boise operates and maintains the nation’s largest geothermal heating district. Today, 91 buildings are connected, providing space heating to over 5.5 million square feet, domestic water heating, laundry and pool heating, sidewalk snowmelt and other related uses. Approximately 300 million gallons of 177°F geothermal water is pumped annually to buildings and institutions located in downtown Boise. The closed loop system returns all used geothermal water back into the aquifer after heat has been removed via an Injection Well. Water injected backmore » into the aquifer has an average temperature of 115°F. This project expanded the Boise Geothermal Heating District (Geothermal System) to bring geothermal energy to the campus of Boise State University and to the Central Addition Eco-District. In addition, this project also improved the overall system’s reliability and increased the hydraulic capacity.« less

  11. Willingness to pay for insecticide-treated nets in Berehet District, Amhara Region, Northern Ethiopia: implication of social marketing.

    PubMed

    Aleme, Adisu; Girma, Eshetu; Fentahun, Netsanet

    2014-01-01

    Understanding the feasibility of achieving widespread coverage with Insecticide-Treated Nets has to be preceded by learning how people value the Insecticide-Treated Nets and estimating the potential demand and willingness to pay so that sustainability of the intervention can be assured. The objective of this study was to determine willingness to pay for Insecticide-Treated Nets among households in Berehet District, Northern Ethiopia. A community-based cross-sectional study was conducted using both quantitative and qualitative methods in five randomly selected Kebeles from January-February 2012. Open ended contingent valuation technique with follow-up method was used. Qualitative data were collected through focus group discussions and observation methods. Binary logistic regression was used to determine the association between dependent and independent variables. The average number of individuals per Insecticide-Treated Nets was 3.83. Nearly 68.5% persons had willingness to buy Insecticide-Treated Nets if they have access to these Nets. The median maximum price a person is willingness to pay for blue rectangular Insecticide-Treated Net was 20 ETB. People had willingness to pay 30 ETB for blue and white conical insecticide-treated nets. Working on knowledge of malaria (OR=0.68, CI (0.47, 0.98; p<0.05), perceived benefit of Insecticide-Treated Nets (OR=0.28, CI (0.2-0.4; p<0.05), perceived susceptibility (OR=0.64(0.44-0.93; p<0.05) and perceived severity of malaria (OR=0.65(0.47-0.91, p<0.05) had significant association with a willingness to pay Insecticide-Treated Nets. Respondents who prefer Kebele/place/ to buy Insecticide-Treated Net for rectangular shape had a significant association with a willingness to pay for Insecticide-Treated Nets (OR=1.92, CI= 1.07-3.92). Promotions, products, price and place had significant association with willingness to pay for Insecticide-Treated Nets. Designing a social marketing strategy helps ensure sustainable supply of Insecticide-Treated Nets and proper use of Insecticide-Treated Nets.

  12. A good night's sleep and the habit of net use: perceptions of risk and reasons for bed net use in Bukoba and Zanzibar.

    PubMed

    Koenker, Hannah M; Loll, Dana; Rweyemamu, Datius; Ali, Abdullah S

    2013-06-13

    Intensive malaria control interventions in the United Republic of Tanzania have contributed to reductions in malaria prevalence. Given that malaria control remains reliant upon continued use of long-lasting insecticidal bed nets (LLINs) even when the threat of malaria has been reduced, this qualitative study sought to understand how changes in perceived risk influence LLIN usage, and to explore in more detail the benefits of net use that are unrelated to malaria. Eleven focus group discussions were conducted in Bukoba Rural district and in Zanzibar Urban West district in late 2011. Participants were males aged 18 and over, females between the ages of 18 and 49, and females at least 50 years old. The perceived risk of malaria had decreased among the respondents, and malaria control interventions were credited for the decline. Participants cited reductions in both the severity of malaria and in their perceived susceptibility to malaria. However, malaria was still considered a significant threat. Participants' conceptualization of risk appeared to be an important consideration for net use. At the same time, comfort and aspects of comfort (getting a good night's sleep, avoiding biting pests) appeared to play a large role in personal decisions to use nets consistently or not. Barriers to comfort (feeling uncomfortable or trapped; perceived difficulty breathing, or itching/rashes) were frequently cited as reasons not to use a net consistently. While it was apparent that participants acknowledged the malaria-prevention benefits of net use, the exploration of the risk and comfort determinants of net use provides a richer understanding of net use behaviours, particularly in a setting where transmission has fallen and yet consistent net use is still crucial to maintaining those gains. Future behaviour change communication campaigns should capitalize on the non-malaria benefits of net use that provide a long-term rationale for consistent use even when the immediate threat of malaria transmission has been reduced.

  13. Bed net ownership in Kenya: the impact of 3.4 million free bed nets

    PubMed Central

    2010-01-01

    Background In July and September 2006, 3.4 million long-lasting insecticide-treated bed nets (LLINs) were distributed free in a campaign targeting children 0-59 months old (CU5s) in the 46 districts with malaria in Kenya. A survey was conducted one month after the distribution to evaluate who received campaign LLINs, who owned insecticide-treated bed nets and other bed nets received through other channels, and how these nets were being used. The feasibility of a distribution strategy aimed at a high-risk target group to meet bed net ownership and usage targets is evaluated. Methods A stratified, two-stage cluster survey sampled districts and enumeration areas with probability proportional to size. Handheld computers (PDAs) with attached global positioning systems (GPS) were used to develop the sampling frame, guide interviewers back to chosen households, and collect survey data. Results In targeted areas, 67.5% (95% CI: 64.6, 70.3%) of all households with CU5s received campaign LLINs. Including previously owned nets, 74.4% (95% CI: 71.8, 77.0%) of all households with CU5s had an ITN. Over half of CU5s (51.7%, 95% CI: 48.8, 54.7%) slept under an ITN during the previous evening. Nearly forty percent (39.1%) of all households received a campaign net, elevating overall household ownership of ITNs to 50.7% (95% CI: 48.4, 52.9%). Conclusions The campaign was successful in reaching the target population, families with CU5s, the risk group most vulnerable to malaria. Targeted distribution strategies will help Kenya approach indicator targets, but will need to be combined with other strategies to achieve desired population coverage levels. PMID:20576145

  14. Bed net ownership in Kenya: the impact of 3.4 million free bed nets.

    PubMed

    Hightower, Allen; Kiptui, Rebecca; Manya, Ayub; Wolkon, Adam; Vanden Eng, Jodi Leigh; Hamel, Mary; Noor, Abdisalan; Sharif, Shahnaz K; Buluma, Robert; Vulule, John; Laserson, Kayla; Slutsker, Laurence; Akhwale, Willis

    2010-06-24

    In July and September 2006, 3.4 million long-lasting insecticide-treated bed nets (LLINs) were distributed free in a campaign targeting children 0-59 months old (CU5s) in the 46 districts with malaria in Kenya. A survey was conducted one month after the distribution to evaluate who received campaign LLINs, who owned insecticide-treated bed nets and other bed nets received through other channels, and how these nets were being used. The feasibility of a distribution strategy aimed at a high-risk target group to meet bed net ownership and usage targets is evaluated. A stratified, two-stage cluster survey sampled districts and enumeration areas with probability proportional to size. Handheld computers (PDAs) with attached global positioning systems (GPS) were used to develop the sampling frame, guide interviewers back to chosen households, and collect survey data. In targeted areas, 67.5% (95% CI: 64.6, 70.3%) of all households with CU5s received campaign LLINs. Including previously owned nets, 74.4% (95% CI: 71.8, 77.0%) of all households with CU5s had an ITN. Over half of CU5s (51.7%, 95% CI: 48.8, 54.7%) slept under an ITN during the previous evening. Nearly forty percent (39.1%) of all households received a campaign net, elevating overall household ownership of ITNs to 50.7% (95% CI: 48.4, 52.9%). The campaign was successful in reaching the target population, families with CU5s, the risk group most vulnerable to malaria. Targeted distribution strategies will help Kenya approach indicator targets, but will need to be combined with other strategies to achieve desired population coverage levels.

  15. KINET: a social marketing programme of treated nets and net treatment for malaria control in Tanzania, with evaluation of child health and long-term survival.

    PubMed

    Schellenberg, J R; Abdulla, S; Minja, H; Nathan, R; Mukasa, O; Marchant, T; Mponda, H; Kikumbih, N; Lyimo, E; Manchester, T; Tanner, M; Lengeler, C

    1999-01-01

    We present a large-scale social marketing programme of insecticide-treated nets in 2 rural districts in southwestern Tanzania (population 350,000) and describe how the long-term child health and survival impact will be assessed. Formative and market research were conducted in order to understand community perceptions, knowledge, attitudes and practice with respect to the products to be socially marketed. We identified Zuia Mbu (Kiswahili for 'prevent mosquitoes') as a suitable brand name for both treated nets and single-dose insecticide treatment sachets. A mix of public and private sales outlets is used for distribution. In the first stage of a stepped introduction 31 net agents were appointed and trained in 18 villages: 15 were shop owners, 14 were village leaders, 1 was a parish priest and 1 a health worker. For net treatment 37 young people were appointed in the same villages and trained as agents. Further institutions in both districts such as hospitals, development projects and employers were also involved in distribution. Promotion for both products was intense and used a variety of channels. A total of 22,410 nets and 8072 treatments were sold during the first year: 18 months after launching, 46% of 312 families with children aged under 5 years reported that their children were sleeping under treated nets. A strong evaluation component in over 50,000 people allows assessment of the long-term effects of insecticide-treated nets on child health and survival, anaemia in pregnancy, and the costs of the intervention. This evaluation is based on cross-sectional surveys, and case-control and cohort studies.

  16. Dying to Play.

    ERIC Educational Resources Information Center

    Miller, John K.

    1998-01-01

    In August 1995, a young football player died as a result of heat exhaustion suffered on the first day of football practice in Arkansas. Spurred by this tragedy, the district made some changes that every school district with an athletic program should consider. These include using a heat-stress monitor; abandoning the practice of group physical…

  17. Efficacy, Outcomes, and Empowerment Evaluation of a School District NET Project. Research Brief.

    ERIC Educational Resources Information Center

    Miller-Whitehead, Marie

    This study addressed the efficacy and outcomes of a U.S. Department of Agriculture Nutrition Education Training (NET) project designed to increase awareness of health risk and wellness factors for grade 9 high school students. The study also considered the empowerment fostered by the program and measured changes in the health and nutrition…

  18. Markets, voucher subsidies and free nets combine to achieve high bed net coverage in rural Tanzania.

    PubMed

    Khatib, Rashid A; Killeen, Gerry F; Abdulla, Salim M K; Kahigwa, Elizeus; McElroy, Peter D; Gerrets, Rene P M; Mshinda, Hassan; Mwita, Alex; Kachur, S Patrick

    2008-06-02

    Tanzania has a well-developed network of commercial ITN retailers. In 2004, the government introduced a voucher subsidy for pregnant women and, in mid 2005, helped distribute free nets to under-fives in small number of districts, including Rufiji on the southern coast, during a child health campaign. Contributions of these multiple insecticide-treated net delivery strategies existing at the same time and place to coverage in a poor rural community were assessed. Cross-sectional household survey in 6,331 members of randomly selected 1,752 households of 31 rural villages of Demographic Surveillance System in Rufiji district, Southern Tanzania was conducted in 2006. A questionnaire was administered to every consenting respondent about net use, treatment status and delivery mechanism. Net use was 62.7% overall, 87.2% amongst infants (0 to 1 year), 81.8% amongst young children (>1 to 5 years), 54.5% amongst older children (6 to 15 years) and 59.6% amongst adults (>15 years). 30.2% of all nets had been treated six months prior to interview. The biggest source of nets used by infants was purchase from the private sector with a voucher subsidy (41.8%). Half of nets used by young children (50.0%) and over a third of those used by older children (37.2%) were obtained free of charge through the vaccination campaign. The largest source of nets amongst the population overall was commercial purchase (45.1% use) and was the primary means for protecting adults (60.2% use). All delivery mechanisms, especially sale of nets at full market price, under-served the poorest but no difference in equity was observed between voucher-subsidized and freely distributed nets. All three delivery strategies enabled a poor rural community to achieve net coverage high enough to yield both personal and community level protection for the entire population. Each of them reached their relevant target group and free nets only temporarily suppressed the net market, illustrating that in this setting that these are complementary rather than mutually exclusive approaches.

  19. The development of the Hong Kong Heat Index for enhancing the heat stress information service of the Hong Kong Observatory.

    PubMed

    Lee, K L; Chan, Y H; Lee, T C; Goggins, William B; Chan, Emily Y Y

    2016-07-01

    This paper presents a study to develop a heat index, for use in hot and humid sub-tropical climate in Hong Kong. The study made use of hospitalization data and heat stress measurement data in Hong Kong from 2007 to 2011. The heat index, which is called Hong Kong Heat Index (HKHI), is calculated from the natural wet bulb temperature, the globe temperature, and the dry bulb temperature together with a set of coefficients applicable to the high humidity condition in the summer of Hong Kong. Analysis of the response of hospitalization rate to variation in HKHI and two other heat indices, namely Wet Bulb Globe Temperature (WBGT) and Net Effective Temperature (NET), revealed that HKHI performed generally better than WBGT and NET in reflecting the heat stress impact on excess hospitalization ratio in Hong Kong. Based on the study results, two reference criteria of HKHI were identified to establish a two-tier approach for the enhancement of the heat stress information service in Hong Kong.

  20. Practical results of heat conservation in a housing estate scale-actions implemented by the Pradnik-Bialy-Zachod housing cooperative in Cracow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piotrowski, L.

    1995-12-31

    There are 11,600,000 apartments occupied in Poland. More than 7,700,000 of these apartments are located in towns. Energy consumption for heating, ventilation and district hot water in residential housing reaches 40% of the national power balance. A portion of district heat distribution and relatively low energy efficiency is characteristic for Polish residential housing. Seventy five percent of apartments in towns are provided with central heating installations and 55% of the entire heat demand in Polish buildings is covered by district heating systems. The total installed heat power of these systems reaches 46,000 MW. The situation with regard to conservation inmore » Polish residential housing is directly related to the legacy of central planning of the national economy and to the current phase of its re-organization to the market-oriented system. The standard value of the overall heat-transfer coefficient for external walls in Poland until 1980 was 1.16 W/m{sup 2}K; at present it is reduced to 0.55 W/m{sup 2}K. There are numerous reasons for the low energy efficiency in residential housing. These reasons are discussed.« less

  1. Surface Heat Budgets and Sea Surface Temperature in the Pacific Warm Pool During TOGA COARE

    NASA Technical Reports Server (NTRS)

    Chou, Shu-Hsien; Zhao, Wenzhong; Chou, Ming-Dah

    1998-01-01

    The daily mean heat and momentum fluxes at the surface derived from the SSM/I and Japan's GMS radiance measurements are used to study the temporal and spatial variability of the surface energy budgets and their relationship to the sea surface temperature during the COARE intensive observing period (IOP). For the three time legs observed during the IOP, the retrieved surface fluxes compare reasonably well with those from the IMET buoy, RV Moana Wave, and RV Wecoma. The characteristics of surface heat and momentum fluxes are very different between the southern and northern warm pool. In the southern warm pool, the net surface heat flux is dominated by solar radiation which is, in turn, modulated by the two Madden-Julian oscillations. The surface winds are generally weak, leading to a shallow ocean mixed layer. The solar radiation penetrating through the bottom of the mixed layer is significant, and the change in the sea surface temperature during the IOP does not follow the net surface heat flux. In the northern warm pool, the northeasterly trade wind is strong and undergoes strong seasonal variation. The variation of the net surface heat flux is dominated by evaporation. The two westerly wind bursts associated with the Madden-Julian oscillations seem to have little effect on the net surface heat flux. The ocean mixed layer is deep, and the solar radiation penetrating through the bottom of the mixed layer is small. As opposed to the southern warm pool, the trend of the sea surface temperature in the northern warm pool during the IOP is in agreement with the variation of the net heat flux at the surface.

  2. Durability of Olyset campaign nets distributed between 2009 and 2011 in eight districts of Tanzania.

    PubMed

    Massue, Dennis J; Moore, Sarah J; Mageni, Zawadi D; Moore, Jason D; Bradley, John; Pigeon, Olivier; Maziba, Erasto J; Mandike, Renata; Kramer, Karen; Kisinza, William N; Overgaard, Hans J; Lorenz, Lena M

    2016-03-18

    Long-lasting insecticidal nets (LLINs) are the first line choice for malaria vector control in sub-Saharan Africa, with most countries adopting universal coverage campaigns. However, there is only limited information on LLIN durability under user conditions. Therefore, this study aimed to assess the durability of Olyset(®) LLINs distributed during campaigns between 2009 and 2011 in Tanzania. A retrospective field survey was conducted in eight districts in Tanzania mainland to assess the durability of Olyset campaign nets. Household questionnaires were used to assess attrition, i.e. net loss. All nets remaining in households were collected. A sub-sample of 198 Olyset campaign nets was examined for bio-efficacy against Anopheles gambiae s.s. mosquitoes, permethrin content and physical integrity following standard World Health Organization (WHO) methods. Of 6067 campaign nets reported to have been received between 2009 and 2011, 35% (2145 nets) were no longer present. Most of those nets had been discarded (84%) mainly because they were too torn (94%). Of the 198 sub-sampled Olyset LLINs, 61% were still in serviceable physical condition sufficient to provide personal protection while 39% were in unserviceable physical condition according to WHO proportionate Hole Index (pHI). More than 96% (116/120) of nets in serviceable condition passed WHO bioefficacy criteria while all nets in unserviceable condition passed WHO bioefficacy criteria. Overall mean permethrin content was 16.5 g/kg (95% CI 16.2-16.9) with 78% of the sub-sampled nets retaining recommended permethrin content regardless of their age or physical condition. Nets aged 4 years and above had a mean permethrin content of 14 g/kg (95% CI 12.0-16.0). The only statistically significant predictor of reduced physical net integrity was rats in the house. Two-to-four years after a mass campaign, only 39% of distributed nets remain both present and in serviceable physical condition, a functional survival considerably below WHO assumptions of 50% survival of a 'three-year' net. However, the majority of nets still retained substantial levels of permethrin and could still be bio-chemically useful against mosquitoes if their holes were repaired, adding evidence to the value of net care and repair campaigns.

  3. Overview of Heat Addition and Efficiency Predictions for an Advanced Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Wilson, Scott D.; Reid, Terry V.; Schifer, Nicholas A.; Briggs, Maxwell H.

    2012-01-01

    The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. Microporous bulk insulation is used in the ground support test hardware to minimize the loss of thermal energy from the electric heat source to the environment. The insulation package is characterized before operation to predict how much heat will be absorbed by the convertor and how much will be lost to the environment during operation. In an effort to validate these predictions, numerous tasks have been performed, which provided a more accurate value for net heat input into the ASCs. This test and modeling effort included: (a) making thermophysical property measurements of test setup materials to provide inputs to the numerical models, (b) acquiring additional test data that was collected during convertor tests to provide numerical models with temperature profiles of the test setup via thermocouple and infrared measurements, (c) using multidimensional numerical models (computational fluid dynamics code) to predict net heat input of an operating convertor, and (d) using validation test hardware to provide direct comparison of numerical results and validate the multidimensional numerical models used to predict convertor net heat input. This effort produced high fidelity ASC net heat input predictions, which were successfully validated using specially designed test hardware enabling measurement of heat transferred through a simulated Stirling cycle. The overall effort and results are discussed.

  4. Simulation of heat losses and ground temperatures for district-heating culverts. Comparison with field experiments for well-insulated, damaged, and extra-insulated culverts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagentoft, C.E.

    1986-01-01

    Many old district-heating culverts are in bad condition due to the entry of water into the thermal insulation. The thermal conductivity, and thereby the heat loss from the culvert, is much larger for a wet than a dry thermal insulation. The high energy prices make it interesting and necessary to find the water-damaged parts of the district-heating culvert and improve the thermal insulation so that a reduction in the heat losses is obtained. The aim of the project is to develop a simple field method to determine the heat loss and the condition of the culvert. The method is basedmore » on the measurement of the temperature on the top of the culvert and a classification of the soil. The classification of the soil gives an estimation of its thermal conductivity. The heat loss and the reduction in heat loss due to an extra insulation is estimated from these data. Five different types of culverts were tested: two types of asbestos cement culverts, one concrete culvert, and two aerated concrete culverts. The comparison of the measured temperatures and the temperatures obtained from the simulations is reported in the study.« less

  5. THE NET IMPACT OF THE CARDOZA AREA DEMONSTRATION PROGRAM, 1964-1965. FIRST YEAR REPORT.

    ERIC Educational Resources Information Center

    FISHMAN, JACOB R.; JONES, ROY J.

    A 1ST-YEAR REPORT OF AN EVALUATION STUDY OF ACTION AND DEMONSTRATION PROGRAMS FOR DELINQUENCY PREVENTION AMONG URBAN GHETTO YOUTH IS PRESENTED. THE PURPOSE OF THE STUDY WAS TO DETERMINE THE NET EFFECTIVENESS OF THE INTERVENTION EFFORTS OF WASHINGTON ACTION FOR YOUTH IN A SCHOOL DISTRICT WITH A HIGH CONCENTRATION OF LOW-INCOME NEGRO YOUTH. THE…

  6. Can the collection of expired long-lasting insecticidal nets reduce their coverage and use? Sociocultural aspects related to LLIN life cycle management and use in four districts in Madagascar.

    PubMed

    Ramanantsoa, Ambinina; Wilson-Barthes, Marta; Rahenintsoa, Rindra; Hoibak, Sarah; Ranaivoharimina, Harilala; Rahelimalala, Martha Delphine; Rakotomanga, Avotiana; Finlay, Alyssa; Muela Ribera, Joan; Peeters Grietens, Koen

    2017-10-10

    There is growing awareness of the likely impact increased numbers of LLINs will have on the environment, if not disposed of or recycled appropriately. As part of a World Health Organization (WHO) and United Nations Environment Programme (UNEP) pilot study to assess environmentally-sound and cost-effective LLIN recycling strategies, the USAID-Deliver Project collected 22,559 used bed nets in Madagascar. A social science study was conducted to provide data on socio-cultural factors related to collection and replacement of LLINs, including impact on primary and other net uses. Ethnographic exploratory research was carried out following the pilot USAID-Deliver net collection and recycling campaign in Betioky, Tsihombe, Fenerive Est and Ambanja districts of Madagascar, triangulating participant observation, interviewing and group discussions. Sampling was theoretical and data analysis was a continuous and iterative process concurrent to data collection. Final analysis was conducted using NVivo10. The following themes emerged as contributing to the success of collecting expired LLINs in the community for recycling purposes: (i) net adequacy and preference: characteristic differences between collected and newly distributed nets lead to communities' reticence to relinquish old nets before confirming new nets were appropriate for intended use. Where newly distributed nets failed to meet local requirements, this was expected to increase alternative uses and decrease household turn over. (ii) Net collection strategies: the net collection campaign brought net use out of the private sphere and into the public arena. Net owners reported feeling ashamed when presenting damaged nets in public for collection, leading to reduced net relinquishment. (iii) Net lifecycle: communities perceived nets as being individually owned and economic value was attributed both to good-condition nets for sleeping and to worn nets for alternative/secondary purposes. Collecting nets at the stage of waste rather than at their prescribed end of life was locally acceptable. The collection of LLINs for recycling/disposal can lead to lower coverage under certain conditions. Collecting used LLINs may be appropriate under the following conditions: (i) nets are collected at the stage of waste; (ii) new nets are in line with community preferences; and (iii) collection strategies have been agreed upon within the community prior to replacement activities. Any collection/recycling of old LLINs should be based on in-depth understanding of the local context and include participatory processes to prevent reduced coverage.

  7. A comparison of economic evaluation models as applied to geothermal energy technology

    NASA Technical Reports Server (NTRS)

    Ziman, G. M.; Rosenberg, L. S.

    1983-01-01

    Several cost estimation and financial cash flow models have been applied to a series of geothermal case studies. In order to draw conclusions about relative performance and applicability of these models to geothermal projects, the consistency of results was assessed. The model outputs of principal interest in this study were net present value, internal rate of return, or levelized breakeven price. The models used were VENVAL, a venture analysis model; the Geothermal Probabilistic Cost Model (GPC Model); the Alternative Power Systems Economic Analysis Model (APSEAM); the Geothermal Loan Guarantee Cash Flow Model (GCFM); and the GEOCOST and GEOCITY geothermal models. The case studies to which the models were applied include a geothermal reservoir at Heber, CA; a geothermal eletric power plant to be located at the Heber site; an alcohol fuels production facility to be built at Raft River, ID; and a direct-use, district heating system in Susanville, CA.

  8. Environmental Assessment and FONSI for the Bison School District Heating Plant Project (Institutional Conservation Program [ICP]).

    ERIC Educational Resources Information Center

    Department of Energy, Washington, DC.

    This paper examines the environmental impacts of replacing the Bison, South Dakota School District's elementary and high school heating system consisting of oil-fired boilers, and supporting electrical components with a new coal-fired boiler and supporting control system piping. Various alternative systems are also examined, including purchasing a…

  9. Molecular wires acting as quantum heat ratchets.

    PubMed

    Zhan, Fei; Li, Nianbei; Kohler, Sigmund; Hänggi, Peter

    2009-12-01

    We explore heat transfer in molecular junctions between two leads in the absence of a finite net thermal bias. The application of an unbiased time-periodic temperature modulation of the leads entails a dynamical breaking of reflection symmetry, such that a directed heat current may emerge (ratchet effect). In particular, we consider two cases of adiabatically slow driving, namely, (i) periodic temperature modulation of only one lead and (ii) temperature modulation of both leads with an ac driving that contains a second harmonic, thus, generating harmonic mixing. Both scenarios yield sizable directed heat currents, which should be detectable with present techniques. Adding a static thermal bias allows one to compute the heat current-thermal load characteristics, which includes the ratchet effect of negative thermal bias with positive-valued heat flow against the thermal bias, up to the thermal stop load. The ratchet heat flow in turn generates also an electric current. An applied electric stop voltage, yielding effective zero electric current flow, then mimics a solely heat-ratchet-induced thermopower ("ratchet Seebeck effect"), although no net thermal bias is acting. Moreover, we find that the relative phase between the two harmonics in scenario (ii) enables steering the net heat current into a direction of choice.

  10. Evapotranspiration Cycles in a High Latitude Agroecosystem: Potential Warming Role

    PubMed Central

    Ruairuen, Watcharee

    2015-01-01

    As the acreages of agricultural lands increase, changes in surface energetics and evapotranspiration (ET) rates may arise consequently affecting regional climate regimes. The objective of this study was to evaluate summertime ET dynamics and surface energy processes in a subarctic agricultural farm in Interior Alaska. The study includes micrometeorological and hydrological data. Results covering the period from June to September 2012 and 2013 indicated consistent energy fractions: LE/R net (67%), G/R net (6%), H/R net (27%) where LE is latent heat flux, R net is the surface net radiation, G is ground heat flux and H is the sensible heat flux. Additionally actual surface evapotranspiration from potential evaporation was found to be in the range of 59 to 66%. After comparing these rates with those of most prominent high latitude ecosystems it is argued here that if agroecosystem in high latitudes become an emerging feature in the land-use, the regional surface energy balance will significantly shift in comparison to existing Arctic natural ecosystems. PMID:26368123

  11. School-Based Health Care and the District of Columbia Safety Net. Medical Homes DC Report

    ERIC Educational Resources Information Center

    21st Century School Fund, 2004

    2004-01-01

    This report provides the results of research into the variety of health care services currently offered in the public schools in the District of Columbia, with a particular focus on school-based health centers. Also provided are the results of research into the practice of utilizing school-based health centers nationally in the U.S. The report is…

  12. Sulfadoxine-Pyrimethamine-Based Intermittent Preventive Treatment, Bed Net Use, and Antenatal Care during Pregnancy: Demographic Trends and Impact on the Health of Newborns in the Kassena Nankana District, Northeastern Ghana

    DTIC Science & Technology

    2010-01-01

    treatment for uncomplicated malaria, whether confirmed, or suspected, in 2004 and SIP- based IPTp was introduced in 2005.1•3 Indoor residual spray - ing...emigrations recorded. Although many women may have been using long - lasting ITNs during pregnancy, this quality of the bed nets could not be determined with...care, provision and wide use of insecticide -treated bed nets (ITNs), and intensified health education. Ghana readily adopted and began implementa

  13. Malaria burden and control in Bangladesh and prospects for elimination: an epidemiological and economic assessment.

    PubMed

    Haque, Ubydul; Overgaard, Hans J; Clements, Archie C A; Norris, Douglas E; Islam, Nazrul; Karim, Jahirul; Roy, Shyamal; Haque, Waziul; Kabir, Moktadir; Smith, David L; Glass, Gregory E

    2014-02-01

    Malaria is endemic in 13 of 64 districts in Bangladesh. About 14 million people are at risk. Some evidence suggests that the prevalence of malaria in Bangladesh has decreased since the the Global Fund to Fight AIDS, Tuberculosis and Malaria started to support the National Malaria Control Program (NMCP) in 2007. We did an epidemiological and economic assessment of malaria control in Bangladesh. We obtained annually reported, district-level aggregated malaria case data and information about disbursed funds from the NMCP. We used a Poisson regression model to examine the associations between total malaria, severe malaria, malaria-attributable mortality, and insecticide-treated net coverage. We identified and mapped malaria hotspots using the Getis-Ord Gi* statistic. We estimated the cost-effectiveness of the NMCP by estimating the cost per confirmed case, cost per treated case, and cost per person of insecticide-treated net coverage. During the study period (from Jan 1, 2008, to Dec 31, 2012) there were 285,731 confirmed malaria cases. Malaria decreased from 6.2 cases per 1000 population in 2008, to 2.1 cases per 1000 population in 2012. Prevalence of all malaria decreased by 65% (95% CI 65-66), severe malaria decreased by 79% (78-80), and malaria-associated mortality decreased by 91% (83-95). By 2012, there was one insecticide-treated net for every 2.6 individuals (SD 0.20). Districts with more than 0.5 insecticide-treated nets per person had a decrease in prevalence of 21% (95% CI 19-23) for all malaria, 25% (17-32) for severe malaria, and 76% (35-91) for malaria-associated mortality among all age groups. Malaria hotspots remained in the highly endemic districts in the Chittagong Hill Tracts. The cost per diagnosed case was US$0.39 (SD 0.02) and per treated case was $0.51 (0.27); $0.05 (0.04) was invested per person per year for health education and $0.68 (0.30) was spent per person per year for insecticide-treated net coverage. Malaria elimination is an achievable prospect in Bangladesh and failure to push for elimination nearly ensures a resurgence of disease. Consistent financing is needed to avoid resurgence and maintain elimination goals. None. Copyright © 2014 Haque et al. Open Access article distributed under the terms of CC BY-NC-ND. Published by .. All rights reserved.

  14. First characterization and comparison of TEB model simulations with in situ measurements regarding radiation balance in a single urban canyon at the BOKU site (Vienna)

    NASA Astrophysics Data System (ADS)

    Oswald, Sandro; Trimmel, Heidelinde; Revesz, Michael; Nadeem, Imran; Masson, Valéry; Weihs, Philipp

    2017-04-01

    According to the World Health Organization more than half of the world population lives in a city since 2010. Predictions foresee that by 2030 six out of ten people will live in an urban area. As a result, many cities are expanding in size. Almost 10% of all urban dwellers live in megacities (defined according to UN HABITAT as a city with a population of more than 10 million). There are several effects in cities which strongly influence human health. Visible influences like the severe emissions of air pollutants by industry and traffic (e.g. Mayer H., 1999, Grimmond et al., 2010) are obvious to people but thermal stress in urban areas is only recently recognized for its strong devastating effect on human health. As a consequence, the urban environment virtually influences all weather parameters that have an impact on human comfort and thermal stress. Within this study, we investigate effects of city growth and the development of outlying districts on the local climate of Vienna. We focus particularly on the influence of urban heat island and consequent the risk for heat related illnesses or thermal stress for people. To quantify radiation balance and other important meteorological factors, we performed an extensive field campaign with three types of net radiometer in three different heights at BOKU site in August 2016. The first results indicated a strong correlation (ρ=0.96) between the Town Energy Balance (TEB) model and the measurements of the top net radiometer regarding radiation balance at roof level, meanwhile the TEB results are slightly underestimated. Further check if the measurements are reasonable, a comparison of the input values (global and direct solar radiation) for the TEB simulation with Secondary Standard measurements of ARAD site Wien Hohe Warte shows a deviation under 2% concerning interquartile range on clear sky days. The next steps will enclose TEB simulations, coupled with the mesoscale Weather Research and Forecasting (WRF) model, for whole Vienna including outlying districts and will quantify a possible future urban climate scenario until 2030. References: Grimmond C.S.B., et al.: Climate and More Sustainable Cities: Climate Information for Improved Planning and Management of Cities (Producers/Capabilities Perspective). Procedia Environmental Sciences 1, 247-274, 2010. Mayer H.: Air pollution in cities. Atmospheric Environment, 33, 4029 - 4037, 1999.

  15. A Comparison of Modeled and Observed Ocean Mixed Layer Behavior in a Sea Breeze Influenced Coastal Region

    DTIC Science & Technology

    1993-12-21

    Latent(Lower Solid), Net Infrared (Dashed), and Net viii Heat Loss (Upper Solid - the Other 3 Surmmed) are Plotted, with Positive Values :ndicating...gained from solar insolation, Qs, and the heat lost from the surface due to latent, Qe, sensible, Qh, and net infrared radiation, Qb is positive...five empirically derived dimensionless constants in the model. With the introduction of two new unknowns, <E> and < ww2 >, the prediction of the upper

  16. "People will say that I am proud": a qualitative study of barriers to bed net use away from home in four Ugandan districts.

    PubMed

    Monroe, April; Harvey, Steven A; Lam, Yukyan; Muhangi, Denis; Loll, Dana; Kabali, Asaph Turinde; Weber, Rachel

    2014-03-06

    Despite increased access and ownership, barriers to insecticide-treated bed net (ITN) use persist. While barriers within the home have been well documented, the challenges to net use when sleeping away from home remain relatively unexplored. This study examines common situations in which people sleep away from home and the barriers to ITN use in those situations. To explore these issues, a group of researchers conducted 28 in-depth interviews and four focus groups amongst adults from net-owning households in four Ugandan districts. In addition to sleeping outside during hot season, participants identified social events, livelihood activities, and times of difficulty as circumstances in which large numbers of people sleep away from home. Associated challenges to ITN use included social barriers such as fear of appearing proud, logistical barriers such as not having a place to hang a net, and resource limitations such as not having an extra net with which to travel. Social disapproval emerged as an important barrier to ITN use in public settings. Unique barriers to ITN use exist when people spend the night away from home. It is essential to identify and address these barriers in order to reduce malaria exposure in such situations. For events like funerals or religious "crusades" where large numbers of people sleep away from home, alternative approaches, such as spatial repellents may be more appropriate than ITNs. Additional research is required to identify the acceptability and feasibility of alternative prevention strategies in situations where ITNs are unlikely to be effective.

  17. Conceptual design study of geothermal district heating of a thirty-house subdivision in Elko, Nevada, using existing water-distribution systems, Phase III. Final technical report, October 1, 1979-September 30, 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitts, D.R.

    1980-09-30

    A conceptual design study for district heating of a 30-home subdivision located near the southeast extremity of the city of Elko, Nevada is presented. While a specific residential community was used in the study, the overall approach and methodologies are believed to be generally applicable for a large number of communities where low temperature geothermal fluid is available. The proposed district heating system utilizes moderate temperature, clean domestic water and existing community culinary water supply lines. The culinary water supply is heated by a moderate temperature geothermal source using a single heat exchanger at entry to the subdivision. The heatedmore » culinary water is then pumped to the houses in the community where energy is extracted by means of a water supplied heat pump. The use of heat pumps at the individual houses allows economic heating to result from supply of relatively cool water to the community, and this precludes the necessity of supplying objectionably hot water for normal household consumption use. Each heat pump unit is isolated from the consumptive water flow such that contamination of the water supply is avoided. The community water delivery system is modified to allow recirculation within the community, and very little rework of existing water lines is required. The entire system coefficient of performance (COP) for a typical year of heating is 3.36, exclusive of well pumping energy.« less

  18. Air-sea heat flux climatologies in the Mediterranean Sea: Surface energy balance and its consistency with ocean heat storage

    NASA Astrophysics Data System (ADS)

    Song, Xiangzhou; Yu, Lisan

    2017-05-01

    This study provides an analysis of the Mediterranean Sea surface energy budget using nine surface heat flux climatologies. The ensemble mean estimation shows that the net downward shortwave radiation (192 ± 19 W m-2) is balanced by latent heat flux (-98 ± 10 W m-2), followed by net longwave radiation (-78 ± 13 W m-2) and sensible heat flux (-13 ± 4 W m-2). The resulting net heat budget (Qnet) is 2 ± 12 W m-2 into the ocean, which appears to be warm biased. The annual-mean Qnet should be -5.6 ± 1.6 W m-2 when estimated from the observed net transport through the Strait of Gibraltar. To diagnose the uncertainty in nine Qnet climatologies, we constructed Qnet from the heat budget equation by using historic hydrological observations to determine the heat content changes and advective heat flux. We also used the Qnet from a data-assimilated global ocean state estimation as an additional reference. By comparing with the two reference Qnet estimates, we found that seven products (NCEP 1, NCEP 2, CFSR, ERA-Interim, MERRA, NOCSv2.0, and OAFlux+ISCCP) overestimate Qnet, with magnitude ranging from 6 to 27 W m-2, while two products underestimate Qnet by -6 W m-2 (JRA55) and -14 W m-2 (CORE.2). Together with the previous warm pool work of Song and Yu (2013), we show that CFSR, MERRA, NOCSv2.0, and OAFlux+ISCCP are warm-biased not only in the western Pacific warm pool but also in the Mediterranean Sea, while CORE.2 is cold-biased in both regions. The NCEP 1, 2, and ERA-Interim are cold-biased over the warm pool but warm-biased in the Mediterranean Sea.

  19. Dynamics behind warming of the southeastern Arabian Sea and its interruption based on in situ measurements

    NASA Astrophysics Data System (ADS)

    Mathew, Simi; Natesan, Usha; Latha, Ganesan; Venkatesan, Ramasamy

    2018-05-01

    A study of the inter-annual variability of the warming of the southeastern Arabian Sea (SEAS) during the spring transition months was carried out from 2013 to 2015 based on in situ data from moored buoys. An attempt was made to identify the roles of the different variables in the warming of the SEAS (e.g., net heat flux, advection, entrainment, and thickness of the barrier layer during the previous northeast monsoon season). The intense freshening of the SEAS (approximately 2 PSU) occurring in each December, together with the presence of a downwelling Rossby wave, supports the formation of a thick barrier layer during the northeast monsoon season. It is known that the barrier layer thickness, varying each year, plays a major role in the spring warming of the SEAS. Interestingly, an anomalously thick barrier layer occurred during the northeast monsoon season of 2012-2013. However, the highest sea surface temperature (31 °C) was recorded during the last week of April 2015, while the lowest sea surface temperature (29.7 °C) was recorded during the last week of May 2013. The mixed layer heat budget analysis during the spring transition months proved that the intense warming has been mainly supported by the net heat flux, not by other factors like advection and entrainment. The inter-annual variability analysis of the net heat flux and its components, averaged over a box region of the SEAS, showed a substantial latent heat flux release and a reduction in net shortwave radiation in 2013. Both factors contributed to the negative net heat flux. Strong breaks in the warming were also observed in May due to the entrainment of cold sub-surface waters. These events are associated with the cyclonic eddy persisting over the SEAS during the same time. The entrainment term, favoring the cooling, was stronger in 2015 than that in 2013 and 2014. The surface temperatures measured in 2013 were lower than those in 2014 and 2015 despite the presence of a thick barrier layer. The substantial decrease in net heat flux along with entrainment cooling has been identified as causes for this behavior.

  20. Energy Retrofit Creates an Efficient Building.

    ERIC Educational Resources Information Center

    Freeman, Laurie

    1997-01-01

    After 20 years of inadequate heating and cooling, an Indiana school district took advantage of a 1994 state law that allows school districts to bypass the "low-bidder wins" restriction. The district established a guaranteed energy-saving contract for a climate-control-improvements package to retrofit the junior-senior high school. (MLF)

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tricaud, Christophe; Ernst, Timothy C.; Zigan, James A.

    The disclosure provides a waste heat recovery system with a system and method for calculation of the net output torque from the waste heat recovery system. The calculation uses inputs from existing pressure and speed sensors to create a virtual pump torque sensor and a virtual expander torque sensor, and uses these sensors to provide an accurate net torque output from the WHR system.

  2. Modeling of District Heating Networks for the Purpose of Operational Optimization with Thermal Energy Storage

    NASA Astrophysics Data System (ADS)

    Leśko, Michał; Bujalski, Wojciech

    2017-12-01

    The aim of this document is to present the topic of modeling district heating systems in order to enable optimization of their operation, with special focus on thermal energy storage in the pipelines. Two mathematical models for simulation of transient behavior of district heating networks have been described, and their results have been compared in a case study. The operational optimization in a DH system, especially if this system is supplied from a combined heat and power plant, is a difficult and complicated task. Finding a global financial optimum requires considering long periods of time and including thermal energy storage possibilities into consideration. One of the most interesting options for thermal energy storage is utilization of thermal inertia of the network itself. This approach requires no additional investment, while providing significant possibilities for heat load shifting. It is not feasible to use full topological models of the networks, comprising thousands of substations and network sections, for the purpose of operational optimization with thermal energy storage, because such models require long calculation times. In order to optimize planned thermal energy storage actions, it is necessary to model the transient behavior of the network in a very simple way - allowing for fast and reliable calculations. Two approaches to building such models have been presented. Both have been tested by comparing the results of simulation of the behavior of the same network. The characteristic features, advantages and disadvantages of both kinds of models have been identified. The results can prove useful for district heating system operators in the near future.

  3. The Surface Energy Budget and Precipitation Efficiency for Convective Systems During TOGA, COARE, GATE, SCSMEX and ARM: Cloud-Resolving Model Simulations

    NASA Technical Reports Server (NTRS)

    Tao, W.-K.; Shie, C.-L.; Johnson, D; Simpson, J.; Starr, David OC. (Technical Monitor)

    2002-01-01

    A two-dimensional version of the Goddard Cumulus Ensemble (GCE) Model is used to simulate convective systems that developed in various geographic locations. Observed large-scale advective tendencies for potential temperature, water vapor mixing ratio, and horizontal momentum derived from field campaigns are used as the main forcing. By examining the surface energy budgets, the model results show that the two largest terms are net condensation (heating/drying) and imposed large-scale forcing (cooling/moistening) for tropical oceanic cases. These two terms arc opposite in sign, however. The contributions by net radiation and latent heat flux to the net condensation vary in these tropical cases, however. For cloud systems that developed over the South China Sea and eastern Atlantic, net radiation (cooling) accounts for about 20% or more of the net condensation. However, short-wave heating and long-wave cooling are in balance with each other for cloud systems over the West Pacific region such that the net radiation is very small. This is due to the thick anvil clouds simulated in the cloud systems over the Pacific region. Large-scale cooling exceeds large-scale moistening in the Pacific and Atlantic cases. For cloud systems over the South China Sea, however, there is more large-scale moistening than cooling even though the cloud systems developed in a very moist environment. though For three cloud systems that developed over a mid-latitude continent, the net radiation and sensible and latent heat fluxes play a much more important role. This means the accurate measurement of surface fluxes and radiation is crucial for simulating these mid-latitude cases.

  4. Cost-effectiveness of social marketing of insecticide-treated nets for malaria control in the United Republic of Tanzania.

    PubMed Central

    Hanson, Kara; Kikumbih, Nassor; Armstrong Schellenberg, Joanna; Mponda, Haji; Nathan, Rose; Lake, Sally; Mills, Anne; Tanner, Marcel; Lengeler, Christian

    2003-01-01

    OBJECTIVE: To assess the costs and consequences of a social marketing approach to malaria control in children by means of insecticide-treated nets in two rural districts of the United Republic of Tanzania, compared with no net use. METHODS: Project cost data were collected prospectively from accounting records. Community effectiveness was estimated on the basis of a nested case-control study and a cross-sectional cluster sample survey. FINDINGS: The social marketing approach to the distribution of insecticide-treated nets was estimated to cost 1560 US dollars per death averted and 57 US dollars per disability-adjusted life year averted. These figures fell to 1018 US dollars and 37 US dollars, respectively, when the costs and consequences of untreated nets were taken into account. CONCLUSION: The social marketing of insecticide-treated nets is an attractive intervention for preventing childhood deaths from malaria. PMID:12764493

  5. District heating with geothermally heated culinary water supply systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitts, D.R.; Schmitt, R.C.

    1979-09-01

    An initial feasibility study of using existing culinary water supply systems to provide hot water for space heating and air conditioning to a typical residential community is reported. The Phase I study has centered on methods of using low-to-moderate temperature water for heating purposes including institutional barriers, identification and description of a suitable residential commnity water system, evaluation of thermal losses in both the main distribution system and the street mains within the residential district, estimation of size and cost of the pumping station main heat exchanger, sizing of individual residential heat exchangers, determination of pumping and power requirements duemore » to increased flow through the residential area mains, and pumping and power requirements from the street mains through a typical residence. All results of the engineering study of Phase I are encouraging.« less

  6. Investigating mosquito net durability for malaria control in Tanzania - attrition, bioefficacy, chemistry, degradation and insecticide resistance (ABCDR): study protocol.

    PubMed

    Lorenz, Lena M; Overgaard, Hans J; Massue, Dennis J; Mageni, Zawadi D; Bradley, John; Moore, Jason D; Mandike, Renata; Kramer, Karen; Kisinza, William; Moore, Sarah J

    2014-12-13

    Long-Lasting Insecticidal Nets (LLINs) are one of the major malaria vector control tools, with most countries adopting free or subsidised universal coverage campaigns of populations at-risk from malaria. It is essential to understand LLIN durability so that public health policy makers can select the most cost effective nets that last for the longest time, and estimate the optimal timing of repeated distribution campaigns. However, there is limited knowledge from few countries of the durability of LLINs under user conditions. This study investigates LLIN durability in eight districts of Tanzania, selected for their demographic, geographic and ecological representativeness of the country as a whole. We use a two-stage approach: First, LLINs from recent national net campaigns will be evaluated retrospectively in 3,420 households. Those households will receive one of three leading LLIN products at random (Olyset®, PermaNet®2.0 or Netprotect®) and will be followed up for three years in a prospective study to compare their performance under user conditions. LLIN durability will be evaluated by measuring Attrition (the rate at which nets are discarded by households), Bioefficacy (the insecticidal efficacy of the nets measured by knock-down and mortality of mosquitoes), Chemical content (g/kg of insecticide available in net fibres) and physical Degradation (size and location of holes). In addition, we will extend the current national mosquito insecticide Resistance monitoring program to additional districts and use these data sets to provide GIS maps for use in health surveillance and decision making by the National Malaria Control Program (NMCP). The data will be of importance to policy makers and vector control specialists both in Tanzania and the SSA region to inform best practice for the maintenance of high and cost-effective coverage and to maximise current health gains in malaria control.

  7. Energy balance comparison of sorghum and sunflower

    NASA Astrophysics Data System (ADS)

    Rachidi, F.; Kirkham, M. B.; Kanemasu, E. T.; Stone, L. R.

    1993-03-01

    An understanding of the energy exchange processes at the surface of the earth is necessary for studies of global climate change. If the climate becomes drier, as is predicted for northern mid-latitudes, it is important to know how major agricultural crops will play a role in the budget of heat and moisture. Thus, the energy balance components of sorghum [ Sorghum bicolor (L.) Moench.] and sunflower ( Helianthus annuus L.), two drought-resistant crops grown in the areas where summertime drying is forecasted, were compared. Soil water content and evapotranspiration ( ET) rates also were determined. Net radiation was measured with net radiometers. Soil heat flux was analyzed with heat flux plates and thermocouples. The Bowen ratio method was used to determine sensible and latent heat fluxes. Sunflower had a higher evapotranspiration rate and depleted more water from the soil than sorghum. Soil heat flux into the soil during the daytime was greater for sorghum than sunflower, which was probably the result of the more erect leaves of sorghum. Nocturnal net radiation loss from the sorghum crop was greater than that from the sunflower crop, perhaps because more heat was stored in the soil under the sorghum crop. But daytime net radiation values were similar for the two crops. The data indicated that models of climate change must differentiate nighttime net radiation of agricultural crops. Sensible heat flux was not always less (or greater) for sorghum compared to sunflower. Sunflower had greater daytime values for latent heat flux, reflecting its greater depletion of water from the soil. Evapotranspiration rates determined by the energy balance method agreed relatively well with those found by the water balance method. For example, on 8 July (43 days after planting), the ET rates found by the energy-balance and water-balance methods were 4.6 vs. 5.5 mm/day for sunflower, respectively; for sorghum, these values were 4.0 vs. 3.5 mm/day, respectively. If the climate does become drier, the lower soil water use and lower latent heat flux of sorghum compared to sunflower suggest that sorghum will be better adapted to the climate change.

  8. Tropical Dynamics Process Studies and Numerical Methods

    DTIC Science & Technology

    2011-06-16

    model. Model input and output arc defined in the Table below. Variable Description Ih Latent heat flux (W/ mA2 ) sh Sensible heat flux (W/ mA2 ) lwo...Net longwave flux (W/ mA2 ) swo Net shortwave flux (W/ mA2 ) 11 Wind speed (m/s) us Atmospheric friction velocity tb Bulk temperature (deg C) dtwo Warm

  9. “People will say that I am proud”: a qualitative study of barriers to bed net use away from home in four Ugandan districts

    PubMed Central

    2014-01-01

    Background Despite increased access and ownership, barriers to insecticide-treated bed net (ITN) use persist. While barriers within the home have been well documented, the challenges to net use when sleeping away from home remain relatively unexplored. This study examines common situations in which people sleep away from home and the barriers to ITN use in those situations. Methods To explore these issues, a group of researchers conducted 28 in-depth interviews and four focus groups amongst adults from net-owning households in four Ugandan districts. Results In addition to sleeping outside during hot season, participants identified social events, livelihood activities, and times of difficulty as circumstances in which large numbers of people sleep away from home. Associated challenges to ITN use included social barriers such as fear of appearing proud, logistical barriers such as not having a place to hang a net, and resource limitations such as not having an extra net with which to travel. Social disapproval emerged as an important barrier to ITN use in public settings. Conclusions Unique barriers to ITN use exist when people spend the night away from home. It is essential to identify and address these barriers in order to reduce malaria exposure in such situations. For events like funerals or religious “crusades” where large numbers of people sleep away from home, alternative approaches, such as spatial repellents may be more appropriate than ITNs. Additional research is required to identify the acceptability and feasibility of alternative prevention strategies in situations where ITNs are unlikely to be effective. PMID:24602371

  10. Community health workers can improve male involvement in maternal health: evidence from rural Tanzania.

    PubMed

    August, Furaha; Pembe, Andrea B; Mpembeni, Rose; Axemo, Pia; Darj, Elisabeth

    2016-01-01

    Male involvement in maternal health is recommended as one of the interventions to improve maternal and newborn health. There have been challenges in realising this action, partly due to the position of men in society and partly due to health system challenges in accommodating men. The aim of this study was therefore to evaluate the effect of Home Based Life Saving Skills training by community health workers on improving male involvement in maternal health in terms of knowledge of danger signs, joint decision-making, birth preparedness, and escorting wives to antenatal and delivery care in a rural community in Tanzania. A community-based intervention consisting of educating the community in Home Based Life Saving Skills by community health workers was implemented using one district as the intervention district and another as comparison district. A pre-/post-intervention using quasi-experimental design was used to evaluate the effect of Home Based Life Saving Skills training on male involvement and place of delivery for their partners. The effect of the intervention was determined using difference in differences analysis between the intervention and comparison data at baseline and end line. The results show there was improvement in male involvement (39.2% vs. 80.9%) with a net intervention effect of 41.1% (confidence interval [CI]: 28.5-53.8; p <0.0001). There was improvement in the knowledge of danger signs during pregnancy, childbirth, and postpartum periods. The proportion of men accompanying their wives to antenatal and delivery also improved. Shared decision-making for place of delivery improved markedly (46.8% vs. 86.7%), showing a net effect of 38.5% (CI: 28.0-49.1; p <0.0001). Although facility delivery for spouses of the participants improved in the intervention district, this did not show statistical significance when compared to the comparison district with a net intervention effect of 12.2% (95% CI: -2.8-27.1: p=0.103). This community-based intervention employing community health workers to educate the community in the Home Based Life Saving Skills programme is both feasible and effective in improving male involvement in maternal healthcare.

  11. Impact of mass distribution of free long-lasting insecticidal nets on childhood malaria morbidity: The Togo National Integrated Child Health Campaign

    PubMed Central

    2010-01-01

    Background An evaluation of the short-term impact on childhood malaria morbidity of mass distribution of free long-lasting insecticidal nets (LLINs) to households with children aged 9-59 months as part of the Togo National Integrated Child Health Campaign. Methods The prevalence of anaemia and malaria in children aged zero to 59 months was measured during two cross-sectional household cluster-sample surveys conducted during the peak malaria transmission, three months before (Sept 2004, n = 2521) and nine months after the campaign (Sept 2005, n = 2813) in three districts representative of Togo's three epidemiological malaria transmission regions: southern tropical coastal plains (Yoto), central fertile highlands (Ogou) and northern semi-arid savannah (Tone). Results In households with children <5 years of age, insecticide-treated net (ITN) ownership increased from <1% to >65% in all 3 districts. Reported ITN use by children during the previous night was 35.9%, 43.8% and 80.6% in Yoto, Ogou and Tone, respectively. Rainfall patterns were comparable in both years. The overall prevalence of moderate to severe anaemia (Hb < 8.0 g/dL) was reduced by 28% (prevalence ratio [PR] 0.72, 95% CI 0.62-0.84) and mean haemoglobin was increased by 0.35 g/dL (95% CI 0.25-0.45). The effect was predominantly seen in children aged 18-59 months and in the two southern districts: PR (95% CI) for moderate to severe anaemia and clinical malaria: Yoto 0.62 (0.44-0.88) and 0.49 (0.35-0.75); Ogou 0.54 (0.37-0.79) and 0.85 (0.57-1.27), respectively. Similar reductions occurred in children <18 months in Ogou, but not in Yoto. No effect was seen in the semi-arid northern district despite a high malaria burden and ITN coverage. Conclusions A marked reduction in childhood malaria associated morbidity was observed in the year following mass distribution of free LLINs in two of the three districts in Togo. Sub-national level impact evaluations will contribute to a better understanding of the impact of expanding national malaria control efforts. PMID:20624305

  12. High-Performance Computing Data Center Waste Heat Reuse | Computational

    Science.gov Websites

    control room With heat exchangers, heat energy in the energy recovery water (ERW) loop becomes available to heat the facility's process hot water (PHW) loop. Once heated, the PHW loop supplies: Active loop in the courtyard of the ESIF's main entrance District heating loop: If additional heat is needed

  13. Solution to problems of bacterial impurity of heating systems

    NASA Astrophysics Data System (ADS)

    Sharapov, V. I.; Zamaleev, M. M.

    2015-09-01

    The article describes the problems of the operation of open and closed district heating systems related to the bacteriological contamination of heating-system water. It is noted that district heating systems are basically safe in sanitary epidemiological terms. Data on the dangers of sulfide contamination of heating systems are given. It is shown that the main causes of the development of sulfate-reducing and iron bacteria in heating systems are a significant biological contamination of source water to fuel heating systems, which is determined by water oxidizability, and a low velocity of the motion of heating-system water in the heating system elements. A case of sulfide contamination of a part of the outdoor heat-supply system of the city of Ulyanovsk is considered in detail. Measures for cleaning pipelines and heating system equipment from the waste products of sulfate-reducing bacteria and iron bacteria and for improving the quality of heating-system water by organizing the hydraulic and water-chemistry condition that makes it possible to avoid the bacteriological contamination of heating systems are proposed. The positive effect of sodium silicate on the prevention of sulfide contamination of heating systems is shown.

  14. Duration of mineralization and fluid-flow history of the Upper Mississippi Valley zinc-lead district

    USGS Publications Warehouse

    Rowan, E.L.; Goldhaber, M.B.

    1995-01-01

    Studies of fluid inclusions in sphalerite and biomarkers from the Upper Mississippi Valley zinc district show homogenization temperatures to be primarily between 90 and 150??C, yet show relatively low levels of thermal maturity. Numerical calculations are used to simulate fluid and heat flow through fracture-controlled ore zones and heat transfer to the adjacent rocks. Combining a best-fit path through fluid-inclusion data with measured thermal alteration of biomarkers, the time interval during which mineralizing fluids circulated through the Upper Mississippi Valley district was calculated to be on the order of 200 ka. Cambrian and Ordovician aquifers underlying the district, principally the St. Peter and Mt. Simon Sandstones, were the source of the mineralizing fluid. The duration of mineralization thus reflects the fluid-flow history of these regional aquifers. -from Authors

  15. Feasibility Study for the Ivano-Frankivsk District Heating Repowering: Analysis of Options

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markel, L.; Popelka, A.; Laskarevsky, V.

    2002-03-20

    Part of the U.S. Initiative on Joint Implementation with the Ukraine Inter-Ministerial Commission on Climate Change, financed by the US Department of Energy. The project was implemented by a team consisting of the US company SenTech, Inc. and the Ukrainian company Esco-West. The main objective of the effort was to assess available alternatives of Ivano-Frankivsk (I-F) District Heating repowering and provide information for I-F's investment decision process. This study provides information on positive and negative technical and economic aspects of available options. Three options were analyzed for technical merit and economic performance: 1. Installation of cogeneration system based on Gasmore » Turbine (GT) and Heat Recovery Heat Exchanger with thermal capacity of 30 MW and electrical capacity of 13.5 MW. This Option assumes utilization of five existing boilers with total capacity of 221 MW. Existing boilers will be equipped with modern controls. Equipment in this Option was sized for longest operating hours, about 8000 based on the available summer baseload. 2. Installation of Gas Turbine Combined Cycle (GTCC) and Heat Recovery Steam Generator (HRSG) with thermal capacity 45 MW and electrical capacity of 58.7 MW. This Option assumes utilization of five existing boilers with total capacity of 221 MW. Existing boilers will be equipped with modern controls. The equipment was sized for medium, shoulder season thermal load, and some cooling was assumed during the summer operation for extension of operating hours for electricity production. 3. Retrofit of six existing boilers (NGB) with total thermal capacity of 255.9 MW by installation of modern control system and minor upgrades. This option assumes only heat production with minimum investment. The best economic performance and the largest investment cost would result from alternative GTCC. This alternative has positive Net Present Value (NPV) with discount rate lower than about 12%, and has IRR slightly above 12%. The lowest economic results, and the lowest required investment, would result from alternative NGB. This Option's NPV is negative even at 0% discount rate, and would not become positive even by improving some parameters within a reasonable range. The Option with Gas Turbine displays relatively modest results and the NPV is positive for low discount rate, higher price of sold electricity and lower cost of natural gas. The IRR of this alternative is 9.75%, which is not very attractive. The largest influences on the investment are from the cost of electricity sold to the grid, the heat tariff, and the cost of natural gas. Assuming the implementation of the GTCC alternative, the benefit of the project is also reflected in lower Green House Emissions.« less

  16. Modelling of Technological Solutions to 4th Generation DH Systems

    NASA Astrophysics Data System (ADS)

    Vigants, Edgars; Prodanuks, Toms; Vigants, Girts; Veidenbergs, Ivars; Blumberga, Dagnija

    2017-11-01

    Flue gas evaporation and condensing processes are investigated in a direct contact heat exchanger - condensing unit, which is installed after a furnace. By using equations describing processes of heat and mass transfer, as well as correlation coherences for determining wet gas parameters, a model is formed to create a no-filling, direct contact heat exchanger. Results of heating equipment modelling and experimental research on the gas condensing unit show, that the capacity of the heat exchanger increases, when return temperature of the district heating network decreases. In order to explain these alterations in capacity, the character of the changes in water vapour partial pressure, in the propelling force of mass transfer, in gas and water temperatures and in the determining parameters of heat transfer are used in this article. The positive impact on the direct contact heat exchanger by the decreased district heating (DH) network return temperature shows that introduction of the 4th generation DH system increases the energy efficiency of the heat exchanger. In order to make an assessment, the methodology suggested in the paper can be used in each particular situation.

  17. Heat of Combustion of the Product Formed by the Reaction of Acetylene, Ethylene, and Diborane

    NASA Technical Reports Server (NTRS)

    Tannenbaum, Stanley

    1957-01-01

    The net heat of combustion of the product formed by the reaction of diborane with a mixture of acetylene and ethylene was found to be 20,440 +/- 150 Btu per pound for the reaction of liquid fuel to gaseous carbon dioxide, gaseous water, and solid boric oxide. The measurements were made in a Parr oxygen-bomb calorimeter, and the combustion was believed to be 98 percent complete. The estimated net-heat of combustion for complete combustion would therefore be 20,850 +/- 150 Btu per pound.

  18. Fluid inclusions and biomarkers in the Upper Mississippi Valley zinc-lead district; implications for the fluid-flow and thermal history of the Illinois Basin

    USGS Publications Warehouse

    Rowan, E. Lanier; Goldhaber, Martin B.

    1996-01-01

    The Upper Mississippi Valley zinc-lead district is hosted by Ordovician carbonate rocks at the northern margin of the Illinois Basin. Fluid inclusion temperature measurements on Early Permian sphalerite ore from the district are predominantly between 90?C and I50?C. These temperatures are greater than can be explained by their reconstructed burial depth, which was a maximum of approximately 1 km at the time of mineralization. In contrast to the temperatures of mineral formation derived from fluid inclusions, biomarker maturities in the Upper Mississippi Valley district give an estimate of total thermal exposure integrated over time. Temperatures from fluid inclusions trapped during ore genesis with biomarker maturities were combined to construct an estimate of the district's overall thermal history and, by inference, the late Paleozoic thermal and hydrologic history of the Illinois Basin. Circulation of groundwater through regional aquifers, given sufficient flow rates, can redistribute heat from deep in a sedimentary basin to its shallower margins. Evidence for regional-scale circulation of fluids is provided by paleomagnetic studies, regionally correlated zoned dolomite, fluid inclusions, and thermal maturity of organic matter. Evidence for igneous acti vity contemporaneous with mineralization in the vicinity of the Upper Mississippi Valley district is absent. Regional fluid and heat circulation is the most likely explanation for the elevated fluid inclusion temperatures (relative to maximum estimated burial depth) in the Upper Mississippi Valley district. One plausible driving mechanism and flow path for the ore-forming fluids is groundwater recharge in the late Paleozoic Appalachian-Ouachita mountain belt and northward flow through the Reelfoot rift and the proto- Illinois Basin to the Upper Mississippi Valley district. Warm fluid flowing laterally through Cambrian and Ordovician aquifers would then move vertically upward through the fractures that control sphalerite mineralization in the Upper Mississippi Valley district. Biomarker reactant-product measurements on rock extracts from the Upper Mississippi Valley district define a relatively low level ofthermal maturity for the district, 0.353 for sterane and 0.577 for hopane. Recently published kinetic constants permit a time-temperature relationship to be determined from these biomarker maturities. Numerical calculations were made to simulate fluid heat flow through the fracture-controlled ore zones of the Thompson-Temperly mine and heat transfer to the adjacent rocks where biomarker samples were collected. Calculations that combine the fluid inclusion temperatures and the biomarker constraints on thermal maturity indicate that the time interval during which mineralizing fluids circulated through the Upper Mississippi Valley district is on the order of 200,000 years. Fluid inclusion measurements and thermal maturities from biomarkers in the district reflect the duration of peak temperatures resulting from regional fluid circulation. On the basis of thermal considerations, the timing of fluorite mineralization in southern Illinois, and the northward-decreasing pattern of fluorine enrichment in sediments, we hypothesize that the principal flow direction was northward through the Cambrian and Ordovician aquifers of the Illinois Basin. A basin-scale flow system would result in mass transport (hydrocarbon migration, transport of metals in solution) and energy (heat) transport, which would in turn drive chemical reactions (for example, maturation of organic matter, mineralization, diagenetic reactions) within the Illinois Basin and at its margins.

  19. Energy Efficiency of Low-Temperature Deaeration of Makeup Water for a District Heating System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharapov, V. I., E-mail: vlad-sharapov2008@yandex.ru; Kudryavtseva, E. V.

    2016-07-15

    It is shown that the temperature of makeup water in district heating systems has a strong effect on the energy efficiency of turbines of thermal power plants. A low-temperature deaeration process that considerably improves the energy efficiency of thermal power plants is developed. The desorbing agent is the gas supplied to the burners of the boiler. The energy efficiency of the process for a typical unit of thermal power plant is assessed.

  20. Surface Oxide Net Charge of a Titanium Alloy; Comparison Between Effects of Treatment With Heat or Radiofrequency Plasma Glow Discharge

    PubMed Central

    MacDonald, Daniel E.; Rapuano, Bruce E.; Schniepp, Hannes C.

    2010-01-01

    In the current study, we have compared the effects of heat and radiofrequency plasma glow discharge (RFGD) treatment of a Ti6Al4V alloy on the physico-chemical properties of the alloy’s surface oxide. Titanium alloy (Ti6Al4V) disks were passivated alone, heated to 600 °C, or RFGD plasma treated in pure oxygen. RFGD treatment did not alter the roughness, topography, elemental composition or thickness of the alloy’s surface oxide layer. In contrast, heat treatment altered oxide topography by creating a pattern of oxide elevations approximately 50–100 nm in diameter. These nanostructures exhibited a three-fold increase in roughness compared to untreated surfaces when RMS roughness was calculated after applying a spatial high-pass filter with a 200 nm cutoff wavelength. Heat treatment also produced a surface enrichment in aluminum and vanadium oxides. Both RFGD and heat treatment produced similar increases in oxide wettability. Atomic force microscopy (AFM) measurements of metal surface oxide net charge signified by a long range force of attraction to or repulsion from a (negatively charged) silicon nitride AFM probe were also obtained for all three experimental groups. Force measurements showed that the RFGD-treated Ti6Al4V samples demonstrated a higher net positive surface charge at pH values below 6 and a higher net negative surface charge at physiological pH (pH values between 7 and 8) compared to control and heat-treated samples These findings suggest that RFGD treatment of metallic implant materials can be used to study the role of negatively charged surface oxide functional groups in protein bioactivity, osteogenic cell behavior and osseointegration independently of oxide topography. PMID:20880672

  1. Evaluation of bednets after 38 months of household use in northwest Ghana.

    PubMed

    Smith, Stephen C; Joshi, Uday B; Grabowsky, Mark; Selanikio, Joel; Nobiya, Theresa; Aapore, Thomas

    2007-12-01

    A total of 255 bednets were collected 38 months after distribution in Lawra District of northwest Ghana to examine their physical condition and residual insecticide levels. Physical condition varied from nearly pristine to highly damaged. In 50 selected nets, 2023 holes > or = 0.5 cm and 31 holes > or = 10 cm were counted. The incidence of holes increases toward the bottom edge of the net. Seam failures were found in 50% of the nets. Repairs, mostly sewn, were evident in 64% of the nets. Using a combination of bromine x-ray fluorescence (XRF) spectrometry, high-pressure liquid chromatography, and cone bioassays, it was determined that 14.9% of the nets had retained full insecticidal strength. These results highlight the value of real-world data on bednet longevity to guide decisions regarding mosquito control strategies, bednet purchasing, frequency of bednet replacement, and product development.

  2. 12. DETAIL, DECORATIVE PANEL, HEAT EXCHANGER (CROPPED PRINT FROM 21/4 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. DETAIL, DECORATIVE PANEL, HEAT EXCHANGER (CROPPED PRINT FROM 2-1/4 x 2-3/4 NEGATIVE) - U.S. General Services Administration, Central Heating Plant, C & D Streets between Twelfth & Thirteenth Streets Southwest, Washington, District of Columbia, DC

  3. Impact of lambdacyhalothrin capsule suspension treated bed nets on malaria in tribal villages of Malkangiri district, Orissa, India.

    PubMed

    Sahu, S S; Vijayakumar, T; Kalyanasundaram, M; Subramanian, S; Jambulingam, P

    2008-09-01

    Insecticide treated mosquito nets are increasingly being used in malaria control programmes. One of the problems with the treatment of bed nets with conventional formulations of insecticides was that regular washing of treated nets diminish insecticidal effect. Lambdacyhalothrin 2.5 capsule suspension (CS) (2.5% a.i., w/v), a new water-based microencapsulated formulation is reported to have wash-resistant property and longer persistence on the netting material than other formulations. We evaluated the impact of the use of nylon bed nets treated with lambdacyhalothrin 2.5 CS at 10 mg (a.i.)/m(2) in comparison to untreated nets and no nets on malaria in tribal villages in Orissa. Nine foothill villages, highly endemic for falciparum malaria, from the Primary Health Centre (PHC) areas of Khairput and Kudumulugumma of Malkangiri district, Orissa, were divided into three groups, each with a population of about 500 and allocated randomly for treated (TN) and untreated nets (UN) and no nets (NN). Bed nets were distributed in September 2001 and retreatment was done in June 2002. The impact was assessed based on the changes in vector density, parous rate, malaria incidence and parasite rates. Indoor-resting collections of Anopheles fluviatilis and An. culicifacies were made at fortnightly intervals from fixed human dwellings. Mass blood surveys before and after distribution of nets and fortnightly active surveillance were carried out to assess the change in parasite rates and malaria incidence. Bioassays were conducted at fortnightly intervals on the bed nets supplied to the villagers. The reductions in indoor resting catches of An. fluviatilis and An. culicifacies were 96 and 38 per cent in villages with treated nets and 2.6 and 23 per cent in villages with untreated nets respectively compared to no net villages. For six months following treatment, 100 per cent mortality of An. fluviatilis was observed on the unwashed nets and on the nets washed once or twice. After re-treatment, 100 per cent mortality of An. fluviatilis or An. culicifacies was observed for nine months even after two washes. Usage rates of treated and untreated nets varied seasonally; 58.9 and 46.3 per cent in rainy season, 48.6 and 37.1 per cent in winter season and 38.1 and 31.6 per cent in summer season respectively. Reductions in malaria parasite rates were about 65 per cent in the treated net villages and 39 per cent in the untreated net villages compared to no net villages. About 75 per cent of treated nets and 60 per cent of untreated nets were in usable condition 19 months after distribution. The estimated protection factor based on malaria incidence was 86 per cent for the treated nets during both post-treatment and post-retreatment periods and 34 and 51 per cent for untreated nets for the corresponding periods compared to no nets. The results of the study showed that the use of bed nets treated nets with CS formulation of lambdacyhalothrin at 10 mg (a.i.)/m(2) was acceptable to the community and re-treatment of nets at nine-monthly intervals can significantly reduce density and survival of An. fluviatilis and incidence of falciparum malaria.

  4. Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Im, Piljae; Liu, Xiaobing; Henderson, Jr., Hugh

    With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station Southmore » (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district GSHP system.« less

  5. Heat of Combustion of the Product Formed by the Reaction of Diborane with 1,3-Butadiene

    NASA Technical Reports Server (NTRS)

    Tannenbaum, Stanley; Allen, Harrison, Jr.

    1953-01-01

    The net heat of combustion of the product formed by the reaction of diborane with 1,3-butadiene was found to be 18,700+/-150 Btu per pound for the reaction of liquid fuel to gaseous carbon dioxide, gaseous water, and solid boric oxide. The measurements were made in a Parr oxygen-bomb calorimeter, and the combustion was believed to be 98 percent complete. The estimated net heat of combustion for complete combustion would therefore be 19,075+/-150 Btu per pound. Since this value is approximately the same as the heat of combustion of butadiene, it seems certain that the material is partially oxidized.

  6. Army Net Zero Prove Out. Net Zero Energy Best Practices

    DTIC Science & Technology

    2014-11-18

    energy which is then used to drive a heat engine to generate electrical power. Geothermal Power – These systems use thermal energy generated and...stored in the earth as a generating source for electricity. Several pilot installations are investigating this technology by conducting geothermal ...concentrate solar thermal energy which is then used to drive a heat engine to generate electrical power. • Geothermal Power - These systems use thermal energy

  7. East Europe Report, Economic and Industrial Affairs

    DTIC Science & Technology

    1985-11-27

    second letter addressed to the editor, J . Behal from Otrokovice writes that 4 years ago he bought a collapsible bicycle, and last year he needed a new...requirements and district heat quantity requirements 19 J • 20 4.2.2 Methodology Determination of the maximum district heat power requirements is made in... j (structural area, community, city) in the year t, POAnit is the total c°nnected load of the region (user group) i in the year t k is a general

  8. District heating and cooling systems for communities through power plant retrofit and distribution network, city of Piqua, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1979-01-01

    The feasibility analysis and evaluation of the Piqua, Ohio District Heating and Cooling Demonstration program is being conducted by the Piqua Municipal Power Co., the Piqua Law Dept., the Public Works Dept., a firm of economic analysts, and the Georgia Tech Engineering Dept. This volume contains information on the organization and composition of the demonstration team; characterization of the Piqua community; and the technical, environmental, institutional; financial, and economic assessments of the project. (LCL)

  9. Solar Thermal Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biesinger, K; Cuppett, D; Dyer, D

    2012-01-30

    HVAC Retrofit and Energy Efficiency Upgrades at Clark High School, Las Vegas, Nevada The overall objectives of this project are to increase usage of alternative/renewable fuels, create a better and more reliable learning environment for the students, and reduce energy costs. Utilizing the grant resources and local bond revenues, the District proposes to reduce electricity consumption by installing within the existing limited space, one principal energy efficient 100 ton adsorption chiller working in concert with two 500 ton electric chillers. The main heating source will be primarily from low nitrogen oxide (NOX), high efficiency natural gas fired boilers. With themore » use of this type of chiller, the electric power and cost requirements will be greatly reduced. To provide cooling to the information technology centers and equipment rooms of the school during off-peak hours, the District will install water source heat pumps. In another measure to reduce the cooling requirements at Clark High School, the District will replace single pane glass and metal panels with Kalwall building panels. An added feature of the Kalwall system is that it will allow for natural day lighting in the student center. This system will significantly reduce thermal heat/cooling loss and control solar heat gain, thus delivering significant savings in heating ventilation and air conditioning (HVAC) costs.« less

  10. White Pine Co. Public School System Biomass Conversion Heating Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul Johnson

    The White Pine County School District and the Nevada Division of Forestry agreed to develop a pilot project for Nevada using wood chips to heat the David E. Norman Elementary School in Ely, Nevada. Consideration of the project was triggered by a ''Fuels for Schools'' grant that was brought to the attention of the School District. The biomass project that was part of a district-wide energy retrofit, called for the installation of a biomass heating system for the school, while the current fuel oil system remained as back-up. Woody biomass from forest fuel reduction programs will be the main sourcemore » of fuel. The heating system as planned and completed consists of a biomass steam boiler, storage facility, and an area for unloading and handling equipment necessary to deliver and load fuel. This was the first project of it's kind in Nevada. The purpose of the DOE funded project was to accomplish the following goals: (1) Fuel Efficiency: Purchase and install a fuel efficient biomass heating system. (2) Demonstration Project: Demonstrate the project and gather data to assist with further research and development of biomass technology; and (3) Education: Educate the White Pine community and others about biomass and other non-fossil fuels.« less

  11. The Effect of Indoor Residual Spraying on the Prevalence of Malaria Parasite Infection, Clinical Malaria and Anemia in an Area of Perennial Transmission and Moderate Coverage of Insecticide Treated Nets in Western Kenya

    PubMed Central

    Gimnig, John E.; Otieno, Peter; Were, Vincent; Marwanga, Doris; Abong’o, Daisy; Wiegand, Ryan; Williamson, John; Wolkon, Adam; Zhou, Ying; Bayoh, M. Nabie; Lobo, Neil F.; Laserson, Kayla; Kariuki, Simon; Hamel, Mary J.

    2016-01-01

    Background Insecticide treated nets (ITNs) and indoor residual spraying (IRS) have been scaled up for malaria prevention in sub-Saharan Africa. However, there are few studies on the benefit of implementing IRS in areas with moderate to high coverage of ITNs. We evaluated the impact of an IRS program on malaria related outcomes in western Kenya, an area of intense perennial malaria transmission and moderate ITN coverage (55–65% use of any net the previous night). Methods The Kenya Division of Malaria Control, with support from the US President’s Malaria Initiative, conducted IRS in one lowland endemic district with moderate coverage of ITNs. Surveys were conducted in the IRS district and a neighboring district before IRS, after one round of IRS in July-Sept 2008 and after a second round of IRS in April-May 2009. IRS was conducted with pyrethroid insecticides. At each survey, 30 clusters were selected for sampling and within each cluster, 12 compounds were randomly selected. The primary outcomes measured in all residents of selected compounds included malaria parasitemia, clinical malaria (P. falciparum infection plus history of fever) and anemia (Hb<8) of all residents in randomly selected compounds. At each survey round, individuals from the IRS district were matched to those from the non-IRS district using propensity scores and multivariate logistic regression models were constructed based on the matched dataset. Results At baseline and after one round of IRS, there were no differences between the two districts in the prevalence of malaria parasitemia, clinical malaria or anemia. After two rounds of IRS, the prevalence of malaria parasitemia was 6.4% in the IRS district compared to 16.7% in the comparison district (OR = 0.36, 95% CI = 0.22–0.59, p<0.001). The prevalence of clinical malaria was also lower in the IRS district (1.8% vs. 4.9%, OR = 0.37, 95% CI = 0.20–0.68, p = 0.001). The prevalence of anemia was lower in the IRS district but only in children under 5 years of age (2.8% vs. 9.3%, OR = 0.30, 95% CI = 0.13–0.71, p = 0.006). Multivariate models incorporating both IRS and ITNs indicated that both had an impact on malaria parasitemia and clinical malaria but the independent effect of ITNs was reduced in the district that had received two rounds of IRS. There was no statistically significant independent effect of ITNs on the prevalence of anemia in any age group. Conclusions Both IRS and ITNs are effective tools for reducing malaria burden and when implemented in an area of moderate to high transmission with moderate ITN coverage, there may be an added benefit of IRS. The value of adding ITNs to IRS is less clear as their benefits may be masked by IRS. Additional monitoring of malaria control programs that implement ITNs and IRS concurrently is encouraged to better understand how to maximize the benefits of both interventions, particularly in the context of increasing pyrethroid resistance. PMID:26731524

  12. School Kicks the Oil Habit.

    ERIC Educational Resources Information Center

    American School and University, 1981

    1981-01-01

    Underground geothermal water from an artesian well supplies heat for rural Haakon School District in Philip (South Dakota). The same water is then piped to the downtown business district a few blocks away and sold as fuel to participating merchants. (Author/MLF)

  13. Fabrication and Testing of a Thin-Film Heat Flux Sensor for a Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Wilson, Scott D.; Fralick, Gustave; Wrbanek, John; Sayir, Ali

    2009-01-01

    The NASA Glenn Research Center (GRC) has been testing high efficiency free-piston Stirling convertors for potential use in radioisotope power systems since 1999. Stirling convertors are being operated for many years to demonstrate a radioisotope power system capable of providing reliable power for potential multi-year missions. Techniques used to monitor the convertors for change in performance include measurements of temperature, pressure, energy addition, and energy rejection. Micro-porous bulk insulation is used in the Stirling convertor test set up to minimize the loss of thermal energy from the electric heat source to the environment. The insulation is characterized before extended operation, enabling correlation of the net thermal energy addition to the convertor. Aging microporous bulk insulation changes insulation efficiency, introducing errors in the correlation for net thermal energy addition. A thin-mm heat flux sensor was designed and fabricated to directly measure the net thermal energy addition to the Stirling convertor. The fabrication techniques include slip casting and using Physical Vapor Deposition (PVD). One micron thick noble metal thermocouples measure temperature on the surface of an Alumina ceramic disc and heat flux is calculated. Fabrication, integration, and test results of a thin film heat flux sensor are presented.

  14. Fabrication and Testing of a Thin-Film Heat Flux Sensor for a Stirling Convertor

    NASA Technical Reports Server (NTRS)

    Wilson, Scott D.; Fralick, Gus c.; Wrbanek, John D.; Sayir, Ali

    2010-01-01

    The NASA Glenn Research Center (GRC) has been testing high-efficiency free-piston Stirling convertors for potential use in radioisotope power systems since 1999. Stirling convertors are being operated for many years to demonstrate a radioisotope power system capable of providing reliable power for potential multiyear missions. Techniques used to monitor the convertors for change in performance include measurements of temperature, pressure, energy addition, and energy rejection. Micro-porous bulk insulation is used in the Stirling convertor test setup to minimize the loss of thermal energy from the electric heat source to the environment. The insulation is characterized before extended operation, enabling correlation of the net thermal energy addition to the convertor. Aging micro-porous bulk insulation changes insulation efficiency, introducing errors in the correlation for net thermal energy addition. A thin-film heat flux sensor was designed and fabricated to directly measure the net thermal energy addition to the Stirling convertor. The fabrication techniques include slipcasting and using Physical Vapor Deposition (PVD). One-micron-thick noble metal thermocouples measure temperature on the surface of an alumina ceramic disk and heat flux is calculated. Fabrication, integration, and test results of a thin-film heat flux sensor are presented.

  15. Effects of steam pretreatment and co-production with ethanol on the energy efficiency and process economics of combined biogas, heat and electricity production from industrial hemp.

    PubMed

    Barta, Zsolt; Kreuger, Emma; Björnsson, Lovisa

    2013-04-22

    The study presented here has used the commercial flow sheeting program Aspen Plus™ to evaluate techno-economic aspects of large-scale hemp-based processes for producing transportation fuels. The co-production of biogas, district heat and power from chopped and steam-pretreated hemp, and the co-production of ethanol, biogas, heat and power from steam-pretreated hemp were analysed. The analyses include assessments of heat demand, energy efficiency and process economics in terms of annual cash flows and minimum biogas and ethanol selling prices (MBSP and MESP). Producing biogas, heat and power from chopped hemp has the highest overall energy efficiency, 84% of the theoretical maximum (based on lower heating values), providing that the maximum capacity of district heat is delivered. The combined production of ethanol, biogas, heat and power has the highest energy efficiency (49%) if district heat is not produced. Neither the inclusion of steam pretreatment nor co-production with ethanol has a large impact on the MBSP. Ethanol is more expensive to produce than biogas is, but this is compensated for by its higher market price. None of the scenarios examined are economically viable, since the MBSP (EUR 103-128 per MWh) is higher than the market price of biogas (EUR 67 per MWh). The largest contribution to the cost is the cost of feedstock. Decreasing the retention time in the biogas process for low solids streams by partly replacing continuous stirred tank reactors by high-rate bioreactors decreases the MBSP. Also, recycling part of the liquid from the effluent from anaerobic digestion decreases the MBSP. The production and prices of methane and ethanol influence the process economics more than the production and prices of electricity and district heat. To reduce the production cost of ethanol and biogas from biomass, the use of feedstocks that are cheaper than hemp, give higher output of ethanol and biogas, or combined production with higher value products are primarily suggested. Further, practical investigations on increased substrate concentration in biogas and ethanol production, recycling of the liquid in anaerobic digestion and separation of low solids flows into solid and a liquid fraction for improved reactor applications deserves further attention.

  16. Effects of steam pretreatment and co-production with ethanol on the energy efficiency and process economics of combined biogas, heat and electricity production from industrial hemp

    PubMed Central

    2013-01-01

    Background The study presented here has used the commercial flow sheeting program Aspen Plus™ to evaluate techno-economic aspects of large-scale hemp-based processes for producing transportation fuels. The co-production of biogas, district heat and power from chopped and steam-pretreated hemp, and the co-production of ethanol, biogas, heat and power from steam-pretreated hemp were analysed. The analyses include assessments of heat demand, energy efficiency and process economics in terms of annual cash flows and minimum biogas and ethanol selling prices (MBSP and MESP). Results Producing biogas, heat and power from chopped hemp has the highest overall energy efficiency, 84% of the theoretical maximum (based on lower heating values), providing that the maximum capacity of district heat is delivered. The combined production of ethanol, biogas, heat and power has the highest energy efficiency (49%) if district heat is not produced. Neither the inclusion of steam pretreatment nor co-production with ethanol has a large impact on the MBSP. Ethanol is more expensive to produce than biogas is, but this is compensated for by its higher market price. None of the scenarios examined are economically viable, since the MBSP (EUR 103–128 per MWh) is higher than the market price of biogas (EUR 67 per MWh). The largest contribution to the cost is the cost of feedstock. Decreasing the retention time in the biogas process for low solids streams by partly replacing continuous stirred tank reactors by high-rate bioreactors decreases the MBSP. Also, recycling part of the liquid from the effluent from anaerobic digestion decreases the MBSP. The production and prices of methane and ethanol influence the process economics more than the production and prices of electricity and district heat. Conclusions To reduce the production cost of ethanol and biogas from biomass, the use of feedstocks that are cheaper than hemp, give higher output of ethanol and biogas, or combined production with higher value products are primarily suggested. Further, practical investigations on increased substrate concentration in biogas and ethanol production, recycling of the liquid in anaerobic digestion and separation of low solids flows into solid and a liquid fraction for improved reactor applications deserves further attention. PMID:23607263

  17. Conservation Yields a Net Profit.

    ERIC Educational Resources Information Center

    Ober, A. Keith

    1979-01-01

    A Vermont school reaped a net "profit" of $13,000 in three years by using commitment, common sense, and caution. Specific measures included changing the hot water system and reducing heating and lighting. (Author/MLF)

  18. The economics of social marketing: the case of mosquito nets in Tanzania.

    PubMed

    Kikumbih, Nassor; Hanson, Kara; Mills, Anne; Mponda, Hadji; Schellenberg, Joanna Armstrong

    2005-01-01

    There is a growing appreciation of the role of the private sector in expanding the use of key health interventions. At the policy level, this has raised questions about how public sector resources can best be used to encourage the private sector in order to achieve public health impact. Social marketing has increasingly been used to distribute public health products in developing countries. The Kilombero and Ulanga Insecticide-Treated Net Project (KINET) project used a social marketing approach in two districts of Tanzania to stimulate the development of the market for insecticide-treated mosquito nets (ITNs) for malaria control. Using evidence from household surveys, focus group discussions and a costing study in the intervention area and a control area, this paper examines two issues: (1) How does social marketing affect the market for ITNs, where this is described in terms of price and coverage levels; and (2) What does the added cost of social marketing "buy" in terms of coverage and equity, compared with an unassisted commercial sector model? It appears that supply improved in both areas, although there was a greater increase in supply in the intervention area. However, the main impact of social marketing on the market for nets was to shift demand in the intervention district, leading to a higher coverage market outcome. While social marketing was more costly per net distributed than the unassisted commercial sector, higher overall levels of coverage were achieved in the social marketing area together with higher coverage of the lowest socioeconomic group, of pregnant women and children under 5 years, and of those living on the periphery of their villages. These findings are interpreted in the context of Tanzania's national plan for scaling up ITNs.

  19. U-values of flat and domed skylights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klems, Joseph H.

    1999-10-01

    Data from nighttime measurements of the net heat flow through several types of skylights is presented. A well-known thermal test facility was reconfigured to measure the net heat flow through the bottom of a skylight/light well combination. Use of this data to determine the U-factor of the skylight is considerably more complicated than the analogous problem of a vertical fenestration contained in a test mask. Correction of the data for heat flow through the skylight well surfaces and evidence for the nature of the heat transfer between the skylight and the bottom of the well is discussed. The resulting measuredmore » U-values are presented and compared with calculations using the WINDOW4 and THERM programs.« less

  20. Channel size influence on the heat flux density at zero net mass flow in the non-linear transport regime between 1.2 and 2.1 K

    NASA Technical Reports Server (NTRS)

    Frederking, T. H. K.; Yuan, S. W. K.; Lee, J. M.; Sun, G. S.

    1987-01-01

    Porous media and narrow ducts of simple shape at zero net mass flow (ZNMF) are used to investigate the influence of pore size on the entropy/heat convection rate at ZNMF. The study is relevant to the development of specific types of phase separators. Previous work on heat transport by convection is extended to porous media without mass loss. The experimental results show the influence of pore size on heat flux for permeabilities between 10 to the -8th and 10 to the -6th sq cm. ZNMF plug data are found to be similar to results obtained for vapor liquid phase separation.

  1. True metabolisable energy, heat increment and net energy values of two high fibre foodstuffs in cockerels.

    PubMed

    Sarmiento-Franco, L; MacLeod, M G; McNab, J M

    2000-12-01

    1. The yields of true metabolisable energy (TME) and net energy (NE) from chaya leaf meal and wheatfeed were mcasured in tube-fed cockerels. 2. TME, 5.76 MJ/kg, from chava leaf meal was lower than from wheatfeed, 8.39 MJ/kg. The total heat increment attributable to the feeding of chaya leaf meal was 1-7 times greater than that of wheatfeed. 3. The net efficiency of utilisation of ME (k) from chaya leaf meal was 0.64, while that from wheatfeed was 0.86. The role of different chemical composition, especially the high fibre content of the materials, is discussed. 4. The metabolisable energy and net energy values derived from chava leaf meal represented 0.34 and 0.23 respectively of its gross energy content. The combination of lower TME and lower net efficiency of utilisation led to chaya having a NE value, 3.86 MJ/kg, which was only 0.53 that of wheatfeed.

  2. Evaluation of Energy Efficient Options to Heat Ohio Department of Transportation (ODOT) Maintenance Facilities

    DOT National Transportation Integrated Search

    2018-01-01

    This project was initiated by the ODOT District 2 staff who were looking for more efficient ways to heat and operate their maintenance facilities. This especially applied to the idea of using radiant floor heating as an alternative to todays stand...

  3. Elevated CO2 maintains grassland net carbon uptake under a future heat and drought extreme

    PubMed Central

    Roy, Jacques; Picon-Cochard, Catherine; Augusti, Angela; Benot, Marie-Lise; Thiery, Lionel; Darsonville, Olivier; Landais, Damien; Piel, Clément; Defossez, Marc; Devidal, Sébastien; Escape, Christophe; Ravel, Olivier; Fromin, Nathalie; Volaire, Florence; Milcu, Alexandru; Bahn, Michael; Soussana, Jean-François

    2016-01-01

    Extreme climatic events (ECEs) such as droughts and heat waves are predicted to increase in intensity and frequency and impact the terrestrial carbon balance. However, we lack direct experimental evidence of how the net carbon uptake of ecosystems is affected by ECEs under future elevated atmospheric CO2 concentrations (eCO2). Taking advantage of an advanced controlled environment facility for ecosystem research (Ecotron), we simulated eCO2 and extreme cooccurring heat and drought events as projected for the 2050s and analyzed their effects on the ecosystem-level carbon and water fluxes in a C3 grassland. Our results indicate that eCO2 not only slows down the decline of ecosystem carbon uptake during the ECE but also enhances its recovery after the ECE, as mediated by increases of root growth and plant nitrogen uptake induced by the ECE. These findings indicate that, in the predicted near future climate, eCO2 could mitigate the effects of extreme droughts and heat waves on ecosystem net carbon uptake. PMID:27185934

  4. Thermocouple frequency response compensation leads to convergence of the surface renewal alpha calibration

    USDA-ARS?s Scientific Manuscript database

    Sensible heat flux measurements are used in conjunction with net radiation and ground heat flux measurements to determine the latent heat flux as the energy balance residual. Surface renewal is a relatively inexpensive technique for sensible heat flux estimation because it requires only a fast-resp...

  5. 33 CFR 165.117 - Regulated Navigation Areas, Safety and Security Zones: Deepwater Ports, First Coast Guard District.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of deepwater port in 33 CFR 148.5. Dredge means fishing gear consisting of a mouth frame attached to... vessel may anchor, engage in diving operations, or commercial fishing using nets, dredges, traps (pots...

  6. Energy Use Consequences of Ventilating a Net-Zero Energy House

    PubMed Central

    Ng, Lisa C.; Payne, W. Vance

    2016-01-01

    A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved compared with ventilation without heat recovery. PMID:26903776

  7. Energy Use Consequences of Ventilating a Net-Zero Energy House.

    PubMed

    Ng, Lisa C; Payne, W Vance

    2016-03-05

    A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved compared with ventilation without heat recovery.

  8. On the energy balance closure and net radiation in complex terrain

    PubMed Central

    Wohlfahrt, Georg; Hammerle, Albin; Niedrist, Georg; Scholz, Katharina; Tomelleri, Enrico; Zhao, Peng

    2017-01-01

    In complex, sloping terrain, horizontal measurements of net radiation are not reflective of the radiative energy available for the conductive and convective heat exchange of the underlying surface. Using data from a grassland site on a mountain slope characterised by spatial heterogeneity in inclination and aspect, we tested the hypothesis that a correction of the horizontal net radiation measurements which accounts for the individual footprint contributions of the various surfaces to the measured sensible and latent heat eddy covariance fluxes will yield more realistic slope-parallel net radiation estimates compared to a correction based on the average inclination and aspect of the footprint. Our main result is that both approaches led to clear, but very similar improvements in the phase between available energy and the sum of the latent and sensible heat fluxes. As a consequence the variance in the sum of latent and sensible heat flux explained by available radiation improved by >10 %, while energy balance closure improved only slightly. This is shown to be mainly due to the average inclination and aspect corresponding largely with the inclination and aspect of the main flux source area in combination with a limited sensitivity of the slope correction to small angular differences in, particularly, inclination and aspect. We conclude with a discussion of limitations of the present approach and future research directions. PMID:28066093

  9. [Malaria: knowledge, behaviour and practices among a rural population of Gossas, Senegal].

    PubMed

    Ndour, C T; Ba, O; Manga, N M; Fortes, M L; Nyamwasa, D; Sow, P S

    2006-10-01

    Malaria remains a major public health problem in Sub-Saharian Africa, in terms of morbidity and mortality rate. To assess the knowledge and behaviour of population regarding the transmission, the treatment and the prevention of malaria, we conducted a cluster sample household survey in Gossas, a rural District in Senegal, from May 2nd to May 6th 2005. A questionnaire that focused on socioeconomic conditions, beliefs, knowledge about and behavior toward antimalarial medication and the prevention means used was given to 480 household owners. Overall, 107 pregnant women and 1,201 children aged less than 5 years old lived within these household. More than a half of the household owners (51%) were illiterate and 25.2% ignored how malaria is transmitted. Fever was the most common symptom suggesting malaria (61%). In 46.1% of febrile cases, people did not seek for treatment from a physician. Home treatment of febrile episodes was based on paracetamol or aspirin (84%), chloroquine (13%) and cotrimoxazole (2.9%). Overall, the proportion of insecticide treated nets users were 22.7%. This percentage was 14.9% and 11.4% for pregnant women and children younger than 5 years old, respectively. People having radio sets, regular access to television, and people aware of the transmission route of malaria were more likely to use bed nets. In most cases, organic material burning was used as repellent against mosquitoes. The low prevalence of bed net use was most often explained by participants' limited accessibility to and by the high cost of insecticide-treated nets. Knowledge about malaria prevention and treatment is low in the rural district of Gossas. The rate of insecticide-treated-bed nets use in vulnerable people is very low, far from the Abuja meeting objective. A sensibilization program and a social marketing plan for insecticide-treated-bed nets could improve this situation.

  10. Sustained Observations of Air-Sea Fluxes and Air-Sea Interaction at the Stratus Ocean Reference Station

    NASA Astrophysics Data System (ADS)

    Weller, Robert

    2014-05-01

    Since October 2000, a well-instrumented surface mooring has been maintained some 1,500 km west of the coast of northern Chile, roughly in the location of the climatological maximum in marine stratus clouds. Statistically significant increases in wind stress and decreases in annual net air-sea heat flux and in latent heat flux have been observed. If the increased oceanic heat loss continues, the region will within the next decade change from one of net annual heat gain by the ocean to one of neat annual heat loss. Already, annual evaporation of about 1.5 m of sea water a year acts to make the warm, salty surface layer more dense. Of interest is examining whether or not increased oceanic heat loss has the potential to change the structure of the upper ocean and potentially remove the shallow warm, salty mixed layer that now buffers the atmosphere from the interior ocean. Insights into how that warm, shallow layer is formed and maintained come from looking at oceanic response to the atmosphere at diurnal tie scales. Restratification each spring and summer is found to depend upon the occurrence of events in which the trade winds decay, allowing diurnal warming in the near-surface ocean to occur, and when the winds return resulting in a net upward step in sea surface temperature. This process is proving hard to accurately model.

  11. Energy exchanges in a Central Business District - Interpretation of Eddy Covariance and radiation flux measurements (London UK)

    NASA Astrophysics Data System (ADS)

    Kotthaus, S.; Grimmond, S.

    2013-12-01

    Global urbanisation brings increasingly dense and complex urban structures. To manage cities sustainably and smartly, currently and into the future under changing climates, urban climate research needs to advance in areas such as Central Business Districts (CBD) where human interactions with the environment are particularly concentrated. Measurement and modelling approaches may be pushed to their limits in dense urban settings, but if urban climate research is to contribute to the challenges of real cities those limits have to be addressed. The climate of cities is strongly governed by surface-atmosphere exchanges of energy, moisture and momentum. Observations of the relevant fluxes provide important information for improvement and evaluation of modelling approaches. Due to the CBD's heterogeneity, a very careful analysis of observations is required to understand the relevant processes. Current approaches used to interpret observations and set them in a wider context may need to be adapted for use in these more complex areas. Here, we present long-term observations of the radiation balance components and turbulent fluxes of latent heat, sensible heat and momentum in the city centre of London. This is one of the first measurement studies in a CBD covering multiple years with analysis at temporal scales from days to seasons. Data gathered at two sites in close vicinity, but with different measurement heights, are analysed to investigate the influence of source area characteristics on long-term radiation and turbulent fluxes. Challenges of source area modelling and the critical aspect of siting in such a complex environment are considered. Outgoing long- and short-wave radiation are impacted by the anisotropic nature of the urban surface and the high reflectance materials increasingly being used as building materials. Results highlight the need to consider the source area of radiometers in terms of diffuse and direct irradiance. Sensible heat fluxes (QH) are positive all year round, even at night. QH systematically exceeds input from net all-wave radiation (Q*), probably sustained by a both storage and anthropogenic heat fluxes (QF). Model estimates suggest QF can exceed the Q* nearly all year round. The positive QH inhibits stable conditions, but the stability classification is determined predominantly by the pattern of friction velocity over the rough urban surface. Turbulent latent heat flux variations are controlled (beyond the available energy) by rainfall due to the small vegetation cover. The Bowen ratio is mostly larger than one. Analysis of the eddy covariance footprint surface controls for the different land cover types by flow patterns for measurements at the two heights suggests the spatial variations of the sensible heat flux observed are partly related to changes in surface roughness, even at the local scale. Where the source areas are most homogeneous, flow conditions are vertically consistent - even if initial morphometric parameters suggested the measurements may be below the blending height. Turbulence statistics and momentum flux patterns prove useful for the interpretation of turbulent heat exchanges observed.

  12. 33 CFR 165.117 - Regulated Navigation Areas, Safety and Security Zones: Deepwater Ports, First Coast Guard District.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of deepwater port in 33 CFR 148.5. Dredge means fishing gear consisting of a mouth frame attached to... vessel may anchor or engage in commercial fishing using nets, dredges, or traps (pots) in the regulated...

  13. Effects of thickness, insulation, and surface color on the net heat loss through an adobe wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herman, R.W.

    1980-01-01

    A finite difference computer program was written and run to study the net thermal losses through a large variety of adobe walls. Fifty-four different combinations of surface color, wall thickness, and insulation position and R value were modeled over a typical two week winter period for locations similar to Albuquerque, New Mexico. A transient analysis of the heat loss from the room to the interior wall surface was compared to both conventional U value and steady-state calculations.

  14. The role of local heating in the 2015 Indian Heat Wave.

    PubMed

    Ghatak, Debjani; Zaitchik, Benjamin; Hain, Christopher; Anderson, Martha

    2017-08-09

    India faced a major heat wave during the summer of 2015. Temperature anomalies peaked in the dry period before the onset of the summer monsoon, suggesting that local land-atmosphere feedbacks involving desiccated soils and vegetation might have played a role in driving the heat extreme. Upon examination of in situ data, reanalysis, satellite observations, and land surface models, we find that the heat wave included two distinct peaks: one in late May, and a second in early June. During the first peak we find that clear skies led to a positive net radiation anomaly at the surface, but there is no significant sensible heat flux anomaly within the core of the heat wave affected region. By the time of the second peak, however, soil moisture had dropped to anomalously low levels in the core heat wave region, net surface radiation was anomalously high, and a significant positive sensible heat flux anomaly developed. This led to a substantial local forcing on air temperature that contributed to the intensity of the event. The analysis indicates that the highly agricultural landscape of North and Central India can reinforce heat extremes under dry conditions.

  15. An application of data mining in district heating substations for improving energy performance

    NASA Astrophysics Data System (ADS)

    Xue, Puning; Zhou, Zhigang; Chen, Xin; Liu, Jing

    2017-11-01

    Automatic meter reading system is capable of collecting and storing a huge number of district heating (DH) data. However, the data obtained are rarely fully utilized. Data mining is a promising technology to discover potential interesting knowledge from vast data. This paper applies data mining methods to analyse the massive data for improving energy performance of DH substation. The technical approach contains three steps: data selection, cluster analysis and association rule mining (ARM). Two-heating-season data of a substation are used for case study. Cluster analysis identifies six distinct heating patterns based on the primary heat of the substation. ARM reveals that secondary pressure difference and secondary flow rate have a strong correlation. Using the discovered rules, a fault occurring in remote flow meter installed at secondary network is detected accurately. The application demonstrates that data mining techniques can effectively extrapolate potential useful knowledge to better understand substation operation strategies and improve substation energy performance.

  16. Benchmark for Performance: Geothermal Applications in Lincoln Public Schools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durfee, D.J.; Hughes, P.J.; Martin, M.A.

    1999-06-19

    Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident among the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less

  17. Benchmark for performance: Geothermal applications in Lincoln public schools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shonder, J.A.; Martin, M.A.; Sharp, T.R.

    1999-07-01

    Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however, these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident amongst the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less

  18. Impact of Insecticide-Treated Net Ownership on All-Cause Child Mortality in Malawi, 2006-2010.

    PubMed

    Florey, Lia S; Bennett, Adam; Hershey, Christine L; Bhattarai, Achuyt; Nielsen, Carrie F; Ali, Doreen; Luhanga, Misheck; Taylor, Cameron; Eisele, Thomas P; Yé, Yazoume

    2017-09-01

    Insecticide-treated nets (ITNs) have been shown to be highly effective at reducing malaria morbidity and mortality in children. However, there are limited studies that assess the association between increasing ITN coverage and child mortality over time, at the national level, and under programmatic conditions. Two analytic approaches were used to examine this association: a retrospective cohort analysis of individual children and a district-level ecologic analysis. To evaluate the association between household ITN ownership and all-cause child mortality (ACCM) at the individual level, data from the 2010 Demographic and Health Survey (DHS) were modeled in a Cox proportional hazards framework while controlling for numerous environmental, household, and individual confounders through the use of exact matching. To evaluate population-level association between ITN ownership and ACCM between 2006 and 2010, program ITN distribution data and mortality data from the 2006 Multiple Indicator Cluster Survey and the 2010 DHS were aggregated at the district level and modeled using negative binomial regression. In the Cox model controlling for household, child and maternal health factors, children between 1 and 59 months in households owning an ITN had significantly lower mortality compared with those without an ITN (hazard ratio = 0.75, 95% confidence interval [CI] = 0.62-90). In the district-level model, higher ITN ownership was significantly associated with lower ACCM (incidence rate ratio = 0.77; 95% CI = 0.60-0.98). These findings suggest that increasing ITN ownership may have contributed to the decline in ACCM during 2006-2010 in Malawi and represent a novel use of district-level data from nationally representative surveys.

  19. What are Up, Down and Net Fluxes?

    Atmospheric Science Data Center

    2014-12-08

    ... Given the vertical layered structure of Earth atmosphere above underlying surfaces, the vertical variability of these fluxes ... for the net energy loss or gain within any two such layers. This concept is important in defining the radiative heating or cooling ...

  20. Which products are available for subsetting?

    Atmospheric Science Data Center

    2014-12-08

    ... users to create smaller files (subsets) of the original data by selecting desired parameters, parameter criterion, or latitude and ... fluxes, where the net flux is constrained to the global heat storage in netCDF format. Single Scanner Footprint TOA/Surface Fluxes ...

  1. Insecticide-treated nets and treatment service: a trial using public and private sector channels in rural United Republic of Tanzania.

    PubMed Central

    Fraser-Hurt, N.; Lyimo, E. O.

    1998-01-01

    The Rotary Net Initiative, implemented in Kilombero District, southern United Republic of Tanzania, allowed us to explore different sales channels for the distribution of insecticide-treated nets (ITNs) and the insecticide treatment service in a rural area of very high malaria transmission. Several types of ITNs were promoted and sold through different channels in the public and private sector, i.e. hospital pharmacy, mother and child health (MCH) clinic, net committee, village health workers and retail shops. The ITNs were sold for US$ 5.0-9.2, with profit margins of 9-16%. Net treatment cost US$ 0.33, with commission fees of 75%. Net transport and treatment were partially subsidized. Some outlets established their own fund by ITN sales. Sales of nets and treatments were seasonal, and certain net types were preferred. Demand for insecticide treatment was generally low. Changes in net coverage were assessed in two villages. A range of outlet features were compared qualitatively. Our experience supports suggestions that ITN technology should be delivered through MCH care services and demonstrates that specific promotion and innovation are necessary to achieve substantial net treatment levels. A large-scale ITN project in the same area and other ITN studies should lead to better understanding of ITN implementation at the population level. PMID:10191557

  2. The Second Law of Thermodynamics in a Historical Setting.

    ERIC Educational Resources Information Center

    Strnad, J.

    1984-01-01

    Traces the development of thermodynamics in physics, focusing on a strategy which enables students to grasp in a limited time and by means of simple calculus the main implications of the second law essential for everyday life (understanding operation of heat engines, refrigerators, heat pumps, district heating, and energy degradation). (JN)

  3. San Jose Unified School District Health & Safety Guide for Facilities and Construction.

    ERIC Educational Resources Information Center

    2001

    This guide from the San Jose Unified School District describes recommended procedures to promote and maintain a healthy and safe school environment during maintenance, modernization, or construction. Guidelines are presented in the following areas: (1) construction safety; (2) communication; (3) material selection; (4) heating, ventilation, and…

  4. Colorado geothermal commercialization program: community development of geothermal energy in Pagosa Springs, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coe, B.A.

    1980-01-01

    A district heating system for the Pagosa Springs central business district is in the planning stage. A detailed analysis of the project is presented. It comprises area and site specific studies and describes in detail the recent, current, anticipated, and postulated geothermal development activities. (MHR)

  5. Multicriteria optimization approach to design and operation of district heating supply system over its life cycle

    NASA Astrophysics Data System (ADS)

    Hirsch, Piotr; Duzinkiewicz, Kazimierz; Grochowski, Michał

    2017-11-01

    District Heating (DH) systems are commonly supplied using local heat sources. Nowadays, modern insulation materials allow for effective and economically viable heat transportation over long distances (over 20 km). In the paper a method for optimized selection of design and operating parameters of long distance Heat Transportation System (HTS) is proposed. The method allows for evaluation of feasibility and effectivity of heat transportation from the considered heat sources. The optimized selection is formulated as multicriteria decision-making problem. The constraints for this problem include a static HTS model, allowing considerations of system life cycle, time variability and spatial topology. Thereby, variation of heat demand and ground temperature within the DH area, insulation and pipe aging and/or terrain elevation profile are taken into account in the decision-making process. The HTS construction costs, pumping power, and heat losses are considered as objective functions. Inner pipe diameter, insulation thickness, temperatures and pumping stations locations are optimized during the decision-making process. Moreover, the variants of pipe-laying e.g. one pipeline with the larger diameter or two with the smaller might be considered during the optimization. The analyzed optimization problem is multicriteria, hybrid and nonlinear. Because of such problem properties, the genetic solver was applied.

  6. Application of thermal energy storage to process heat recovery in the aluminum industry

    NASA Technical Reports Server (NTRS)

    Mccabe, J.

    1980-01-01

    The economic viability and the institutional compatibility of a district heating system in the city of Bellingham, Washington are assessed and the technical and economic advantages of using thermal energy storage methods are determined.

  7. Relationship Between Sea Surface Temperature and Surface Heat Balance Trends in the Tropical Oceans: The Crucial Role of Surface Wind Trends

    NASA Astrophysics Data System (ADS)

    Cook, K. H.; Vizy, E. K.; Sun, X.

    2016-12-01

    Multiple atmospheric and ocean reanalyses are analyzed for 1980-2015 to understand annual-mean adjustments of the surface heat balance over the tropical oceans as the climate warms. Linear trends are examined, with statistical significance evaluated. While surface heat budgets and sea surface temperatures are mutually adjusted fields, insights into the physical processes of this adjustment and the implications for temperature trends can be identified. Two second-generation reanalyses, ERA-Interim and JRA-55, agree well on the distributions and magnitudes of trends in the net heat flux from the atmosphere to the ocean. Trends in the net longwave and sensible heat fluxes are generally small, and trends in solar radiation absorbed are only influential regionally and vary among the reanalyses. The largest contribution is from latent heat flux trends. Contributions to these trends associated with surface temperature (thermal-driving), 10-m wind (dynamical-driving) and specific humidity (hydrological-driving) trends are estimated. The dynamically-driven latent heat flux dominates and explains much of the regionality of the multi-decadal heat flux trends. However, trends in the net surface heat flux alone do not match the observed SSTs trends well, indicating that the redistribution of heat within the ocean mixed layer is also important. Ocean mixed layer heat budgets in various ocean reanalyses are examined to understand this redistribution, and we again identify a crucial role for changes in the surface wind. Acceleration of the tropical easterlies is associated with strengthening of the equatorial undercurrents in both the tropical Pacific and Atlantic. In the Pacific, where the EUC is also shoaling, the result is enhanced warm-water advection into the central Pacific. This advective warming is superimposed on cooling due to enhanced evaporation and equatorial upwelling, which are also associated with wind trends, to determine the observed pattern of SST trends.

  8. Optimal Management of Geothermal Heat Extraction

    NASA Astrophysics Data System (ADS)

    Patel, I. H.; Bielicki, J. M.; Buscheck, T. A.

    2015-12-01

    Geothermal energy technologies use the constant heat flux from the subsurface in order to produce heat or electricity for societal use. As such, a geothermal energy system is not inherently variable, like systems based on wind and solar resources, and an operator can conceivably control the rate at which heat is extracted and used directly, or converted into a commodity that is used. Although geothermal heat is a renewable resource, this heat can be depleted over time if the rate of heat extraction exceeds the natural rate of renewal (Rybach, 2003). For heat extraction used for commodities that are sold on the market, sustainability entails balancing the rate at which the reservoir renews with the rate at which heat is extracted and converted into profit, on a net present value basis. We present a model that couples natural resource economic approaches for managing renewable resources with simulations of geothermal reservoir performance in order to develop an optimal heat mining strategy that balances economic gain with the performance and renewability of the reservoir. Similar optimal control approaches have been extensively studied for renewable natural resource management of fisheries and forests (Bonfil, 2005; Gordon, 1954; Weitzman, 2003). Those models determine an optimal path of extraction of fish or timber, by balancing the regeneration of stocks of fish or timber that are not harvested with the profit from the sale of the fish or timber that is harvested. Our model balances the regeneration of reservoir temperature with the net proceeds from extracting heat and converting it to electricity that is sold to consumers. We used the Non-isothermal Unconfined-confined Flow and Transport (NUFT) model (Hao, Sun, & Nitao, 2011) to simulate the performance of a sedimentary geothermal reservoir under a variety of geologic and operational situations. The results of NUFT are incorporated into the natural resource economics model to determine production strategies that maximize net present value given the performance of the geothermal resource.

  9. Population turnover and churn: enhancing understanding of internal migration in Britain through measures of stability.

    PubMed

    Dennett, Adam; Stillwell, John

    2008-01-01

    Net migration measures take account of the direction of migration flows, but our understanding of migration can be extended using population turnover and churn as measures of population stability. Turnover is a measure of the intensity of migration into and out of a district, whereas churn incorporates these flows and also includes the flows that take place within each district. Using districts of Britain and their type-based groupings, the highest levels of turnover and churn are found in London and some of the more dynamic urban areas, whereas the lowest levels are found in rural and previously industrial areas. Age has a significant effect on these measures with the population in their late teens and early twenties being the least stable and older populations being more stable.

  10. Cogeneration and beyond: The need and opportunity for high efficiency, renewable community energy systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gleason, T.C.J.

    1992-06-01

    The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.

  11. 78 FR 64569 - Self-Regulatory Organizations; NASDAQ OMX PHLX LLC; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-29

    ... United States Court of Appeals for the District of Columbia Circuit in NetCoaliton v. SEC, 615 F.3d 525... with the provisions of 5 U.S.C. 552, will be available for Web site viewing and printing in the...

  12. Applying Statement 34's Capital Asset Requirements.

    ERIC Educational Resources Information Center

    Finden, Randal

    2001-01-01

    Discusses common issues and offers recommendations related to revisions in Governmental Accounting Standards Board Statement 34 wherein the financial reporting of the general fixed-assets account group is eliminated and instead a school district's general capital assets are reported and depreciated on the new statement of net assets and statement…

  13. Why We (AAHPERD Leaders) Do What We Do

    ERIC Educational Resources Information Center

    Strand, Bradford; Worrell, Vicki; Wiedow, Gale

    2013-01-01

    At a recent American Alliance for Health, Physical Education, Recreation and Dance (AAHPERD) Leadership Development Conference, presidents-elect representing state, district, and national AAHPERD associations were asked to describe in one sentence why they do what they do. The 67 responses were entered into wordle.net that generated the 20-item…

  14. Paving the Road to Technology Integration

    ERIC Educational Resources Information Center

    Mulligan, Angie; Strong, Mary; Crabbe, Jill; Steen, Patricia

    2006-01-01

    During the 2004-2005 school year, Community Consolidated School District 146, in Tinley Park, Illinois, embarked on a journey to become more familiar with the National Educational Technology Standards (NETS). This journey culminated with the launch of a comprehensive WebQuest for third graders about the American Revolution. The detail that sets…

  15. Gentrification and Displacement of the Elderly: An Empirical Analysis.

    ERIC Educational Resources Information Center

    Henig, Jeffrey R.

    1981-01-01

    Analyzes census tract data to assess residential mobility trends. Net immigration of professionals is found to be more likely in tracts with high proportions of retired households and, especially in tracts close to the cities' central business districts, professional immigration is associated with outmigration of retired households. (Author)

  16. Coal-Fired Power Plant Heat Rate Reductions

    EPA Pesticide Factsheets

    View a report that identifies systems and equipment in coal-fired power plants where efficiency improvements can be realized, and provides estimates of the resulting net plant heat rate reductions and costs for implementation.

  17. Urban surface energy fluxes based on remotely-sensed data and micrometeorological measurements over the Kansai area, Japan

    NASA Astrophysics Data System (ADS)

    Sukeyasu, T.; Ueyama, M.; Ando, T.; Kosugi, Y.; Kominami, Y.

    2017-12-01

    The urban heat island is associated with land cover changes and increases in anthropogenic heat fluxes. Clear understanding of the surface energy budget at urban area is the most important for evaluating the urban heat island. In this study, we develop a model based on remotely-sensed data for the Kansai area in Japan and clarify temporal transitions and spatial distributions of the surface energy flux from 2000 to 2016. The model calculated the surface energy fluxes based on various satellite and GIS products. The model used land surface temperature, surface emissivity, air temperature, albedo, downward shortwave radiation and land cover/use type from the moderate resolution imaging spectroradiometer (MODIS) under cloud free skies from 2000 to 2016 over the Kansai area in Japan (34 to 35 ° N, 135 to 136 ° E). Net radiation was estimated by a radiation budget of upward/downward shortwave and longwave radiation. Sensible heat flux was estimated by a bulk aerodynamic method. Anthropogenic heat flux was estimated by the inventory data. Latent heat flux was examined with residues of the energy budget and parameterization of bulk transfer coefficients. We validated the model using observed fluxes from five eddy-covariance measurement sites: three urban sites and two forested sites. The estimated net radiation roughly agreed with the observations, but the sensible heat flux were underestimated. Based on the modeled spatial distributions of the fluxes, the daytime net radiation in the forested area was larger than those in the urban area, owing to higher albedo and land surface temperatures in the urban area than the forested area. The estimated anthropogenic heat flux was high in the summer and winter periods due to increases in energy-requirements.

  18. Investigation of bypass fluid flow in an active magnetic regenerative liquefier

    DOE PAGES

    Holladay, Jamelyn; Teyber, Reed; Meinhardt, Kerry; ...

    2018-05-19

    Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass imbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a functionmore » of the bypass flow fraction. In conclusion, experiments are performed at a fixed temperature span yielding a 30% improvement in net cooling power, affirming the potential of bypass flow in active magnetic regenerative liquefiers.« less

  19. Investigation of bypass fluid flow in an active magnetic regenerative liquefier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holladay, Jamelyn; Teyber, Reed; Meinhardt, Kerry

    Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass imbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a functionmore » of the bypass flow fraction. Experiments are performed at a fixed temperature span yielding a 30% improvement in net cooling power, affirming the potential of bypass flow in active magnetic regenerative liquefiers.« less

  20. Investigation of bypass fluid flow in an active magnetic regenerative liquefier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holladay, Jamelyn; Teyber, Reed; Meinhardt, Kerry

    Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass imbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a functionmore » of the bypass flow fraction. In conclusion, experiments are performed at a fixed temperature span yielding a 30% improvement in net cooling power, affirming the potential of bypass flow in active magnetic regenerative liquefiers.« less

  1. Mixed Layer Temperature Budget for the Northward Propagating Summer Monsoon Intraseasonal Oscillation (MISO) in the Central Bay of Bengal

    NASA Astrophysics Data System (ADS)

    Girishkumar, M. S.; Joseph, J.; Thangaprakash, V. P.; Pottapinjara, V.; McPhaden, M. J.

    2017-11-01

    Composite analyses of mixed layer temperature (MLT) budget terms from near-surface meteorological and oceanic observations in the central Bay of Bengal are utilized to evaluate the modulation of air-sea interactions and MLT processes in response to the summer monsoon intraseasonal oscillation (MISO). For this purpose, we use moored buoy data at 15°N, 12°N, and 8°N along 90°E together with TropFlux meteorological parameters and the Ocean Surface Current Analyses Real-time (OSCAR) current product. Our analysis shows a strong cooling tendency in MLT with maximum amplitude in the central and northern BoB during the northward propagation of enhanced convective activity associated with the active phase of the MISO; conversely, warming occurs during the suppressed phase of the MISO. The surface mixed layer is generally heated during convectively inactive phases of the MISO primarily due to increased net surface heat flux into the ocean. During convectively active MISO phases, the surface mixed layer is cooled by the combined influence of net surface heat loss to the atmosphere and entrainment cooling at the base of mixed layer. The variability of net surface heat flux is primarily due to modulation of latent heat flux and shortwave radiation. Shortwave is mostly controlled by an enhancement or reduction of cloudiness during the active and inactive MISO phases and latent heat flux is mostly controlled by variations in air-sea humidity difference.

  2. Possibility of using adsorption refrigeration unit in district heating network

    NASA Astrophysics Data System (ADS)

    Grzebielec, Andrzej; Rusowicz, Artur; Jaworski, Maciej; Laskowski, Rafał

    2015-09-01

    Adsorption refrigeration systems are able to work with heat sources of temperature starting with 50 °C. The aim of the article is to determine whether in terms of technical and economic issues adsorption refrigeration equipment can work as elements that produce cold using hot water from the district heating network. For this purpose, examined was the work of the adsorption air conditioning equipment cooperating with drycooler, and the opportunities offered by the district heating network in Warsaw during the summer. It turns out that the efficiency of the adsorption device from the economic perspective is not sufficient for production of cold even during the transitional period. The main problem is not the low temperature of the water supply, but the large difference between the coefficients of performance, COPs, of adsorption device and a traditional compressor air conditioning unit. When outside air temperature is 25 °C, the COP of the compressor type reaches a value of 4.49, whereas that of the adsorption device in the same conditions is 0.14. The ratio of the COPs is 32. At the same time ratio between the price of 1 kWh of electric power and 1 kWh of heat is only 2.85. Adsorption refrigeration equipment to be able to compete with compressor devices, should feature COPads efficiency to be greater than 1.52. At such a low driving temperature and even changing the drycooler into the evaporative cooler it is not currently possible to achieve.

  3. Philip, South Dakota geothermal district heating systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lund, J.W.

    1997-12-01

    The geothermal heating project in Philip, South Dakota which uses the waste water from the Haakon School has now been in operation for 15 years. This project was one of the 23 cost shared by the U.S. DOE starting in 1978, of which 15 became operational. This article describes the geothermal heating system for eight buildings in downtown Philip.

  4. Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Townsend, Terry; Slusher, Scott

    The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

  5. Evolutionary transformation of communal thermal-power engineering

    NASA Astrophysics Data System (ADS)

    Nakorchevskii, A. I.

    2013-01-01

    A solution is given to the problem of heat supply to multi-storied residential and office buildings with the use of solar insolation as the principal energy source making it possible to do away with the district heating of towns and settlements and to reduce expenditure of energy on heating and hot water supply by more than 85%.

  6. Optimization of Borehole Thermal Energy Storage System Design Using Comprehensive Coupled Simulation Models

    NASA Astrophysics Data System (ADS)

    Welsch, Bastian; Rühaak, Wolfram; Schulte, Daniel O.; Formhals, Julian; Bär, Kristian; Sass, Ingo

    2017-04-01

    Large-scale borehole thermal energy storage (BTES) is a promising technology in the development of sustainable, renewable and low-emission district heating concepts. Such systems consist of several components and assemblies like the borehole heat exchangers (BHE), other heat sources (e.g. solarthermics, combined heat and power plants, peak load boilers, heat pumps), distribution networks and heating installations. The complexity of these systems necessitates numerical simulations in the design and planning phase. Generally, the subsurface components are simulated separately from the above ground components of the district heating system. However, as fluid and heat are exchanged, the subsystems interact with each other and thereby mutually affect their performances. For a proper design of the overall system, it is therefore imperative to take into account the interdependencies of the subsystems. Based on a TCP/IP communication we have developed an interface for the coupling of a simulation package for heating installations with a finite element software for the modeling of the heat flow in the subsurface and the underground installations. This allows for a co-simulation of all system components, whereby the interaction of the different subsystems is considered. Furthermore, the concept allows for a mathematical optimization of the components and the operational parameters. Consequently, a finer adjustment of the system can be ensured and a more precise prognosis of the system's performance can be realized.

  7. Impacts of changing cropping pattern on virtual water flows related to crops transfer: a case study for the Hetao irrigation district, China.

    PubMed

    Liu, Jing; Wu, Pute; Wang, Yubao; Zhao, Xining; Sun, Shikun; Cao, Xinchun

    2014-11-01

    Analysis of cropping patterns is a prerequisite for their optimisation, and evaluation of virtual water flows could shed new light on water resources management. This study is intended to explore the effects of cropping pattern changes between 1960 and 2008 on virtual water flows related to crops transfer in the Hetao irrigation district, China. (1) The sown area of crops increased at an average rate of 3.57 × 10(3) ha year(-1) while the proportion of sown grain crops decreased from 92.83% in the 1960s to 50.22% in the 2000s. (2) Virtual water content decreased during the study period while net virtual water exports increased since the 1980s. (3) Assuming that the cropping pattern was constant and was equal to the average 1960s value, accumulated net virtual water export in 1980-2008 would have been 4.76 × 10(9) m(3) greater than that in the actual cropping pattern scenario. Cropping pattern changes in the Hetao irrigation district could not only be seen as resulting from the pursuit for higher economic returns, but also as a feedback response to limited water resources. A systematic framework is still needed for future cropping pattern planning by taking food security, continued agricultural expansion and other constraints into consideration. © 2014 Society of Chemical Industry.

  8. Debates over School Shutdowns Heating Up

    ERIC Educational Resources Information Center

    Zubrzycki, Jaclyn

    2012-01-01

    As school closures are increasingly used as a remedy to budget woes and a solution to failing schools in many cities, debates are intensifying about their effect on student performance and well-being, on district finances, and on communities and the processes districts use to choose which schools will be shuttered. Student and parent groups in…

  9. Building a Construction Curriculum for Your School District

    ERIC Educational Resources Information Center

    Ruder, Robert

    2010-01-01

    Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for…

  10. Implementation of heat-straightening repairs for Louisiana bridges.

    DOT National Transportation Integrated Search

    1998-12-01

    The goal of this study was to implement the latest heat-straightening repair technology on a Louisiana Bridge. The bridge chosen was an overpass just east of Lake Charles crossing 1-10. Working with both state and district personnel, the bridge was r...

  11. Combined heat and power supply using Carnot engines

    NASA Astrophysics Data System (ADS)

    Horlock, J. H.

    The Marshall Report on the thermodynamic and economic feasibility of introducing large scale combined heat and electrical power generation (CHP) into the United Kingdom is summarized. Combinations of reversible power plant (Carnot engines) to meet a given demand of power and heat production are analyzed. The Marshall Report states that fairly large scale CHP plants are an attractive energy saving option for areas of high heat load densities. Analysis shows that for given requirements, the total heat supply and utilization factor are functions of heat output, reservoir supply temperature, temperature of heat rejected to the reservoir, and an intermediate temperature for district heating.

  12. Analysing surface energy balance closure and partitioning over a semi-arid savanna FLUXNET site in Skukuza, Kruger National Park, South Africa

    NASA Astrophysics Data System (ADS)

    Majozi, Nobuhle P.; Mannaerts, Chris M.; Ramoelo, Abel; Mathieu, Renaud; Nickless, Alecia; Verhoef, Wouter

    2017-07-01

    Flux towers provide essential terrestrial climate, water, and radiation budget information needed for environmental monitoring and evaluation of climate change impacts on ecosystems and society in general. They are also intended for calibration and validation of satellite-based Earth observation and monitoring efforts, such as assessment of evapotranspiration from land and vegetation surfaces using surface energy balance approaches. In this paper, 15 years of Skukuza eddy covariance data, i.e. from 2000 to 2014, were analysed for surface energy balance closure (EBC) and partitioning. The surface energy balance closure was evaluated using the ordinary least squares regression (OLS) of turbulent energy fluxes (sensible (H) and latent heat (LE)) against available energy (net radiation (Rn) less soil heat (G)), and the energy balance ratio (EBR). Partitioning of the surface energy during the wet and dry seasons was also investigated, as well as how it is affected by atmospheric vapour pressure deficit (VPD), and net radiation. After filtering years with low-quality data (2004-2008), our results show an overall mean EBR of 0.93. Seasonal variations of EBR also showed the wet season with 1.17 and spring (1.02) being closest to unity, with the dry season (0.70) having the highest imbalance. Nocturnal surface energy closure was very low at 0.26, and this was linked to low friction velocity during night-time, with results showing an increase in closure with increase in friction velocity. The energy partition analysis showed that sensible heat flux is the dominant portion of net radiation, especially between March and October, followed by latent heat flux, and lastly the soil heat flux, and during the wet season where latent heat flux dominated sensible heat flux. An increase in net radiation was characterized by an increase in both LE and H, with LE showing a higher rate of increase than H in the wet season, and the reverse happening during the dry season. An increase in VPD is correlated with a decrease in LE and increase in H during the wet season, and an increase in both fluxes during the dry season.

  13. Impact of Insecticide-Treated Net Ownership on All-Cause Child Mortality in Malawi, 2006–2010

    PubMed Central

    Florey, Lia S.; Bennett, Adam; Hershey, Christine L.; Bhattarai, Achuyt; Nielsen, Carrie F.; Ali, Doreen; Luhanga, Misheck; Taylor, Cameron; Eisele, Thomas P.; Yé, Yazoume

    2017-01-01

    Abstract. Insecticide-treated nets (ITNs) have been shown to be highly effective at reducing malaria morbidity and mortality in children. However, there are limited studies that assess the association between increasing ITN coverage and child mortality over time, at the national level, and under programmatic conditions. Two analytic approaches were used to examine this association: a retrospective cohort analysis of individual children and a district-level ecologic analysis. To evaluate the association between household ITN ownership and all-cause child mortality (ACCM) at the individual level, data from the 2010 Demographic and Health Survey (DHS) were modeled in a Cox proportional hazards framework while controlling for numerous environmental, household, and individual confounders through the use of exact matching. To evaluate population-level association between ITN ownership and ACCM between 2006 and 2010, program ITN distribution data and mortality data from the 2006 Multiple Indicator Cluster Survey and the 2010 DHS were aggregated at the district level and modeled using negative binomial regression. In the Cox model controlling for household, child and maternal health factors, children between 1 and 59 months in households owning an ITN had significantly lower mortality compared with those without an ITN (hazard ratio = 0.75, 95% confidence interval [CI] = 0.62–90). In the district-level model, higher ITN ownership was significantly associated with lower ACCM (incidence rate ratio = 0.77; 95% CI = 0.60–0.98). These findings suggest that increasing ITN ownership may have contributed to the decline in ACCM during 2006–2010 in Malawi and represent a novel use of district-level data from nationally representative surveys. PMID:28990922

  14. Plasma vitrification and re-use of non-combustible fiber reinforced plastic, gill net and waste glass.

    PubMed

    Chu, J P; Chen, Y T; Mahalingam, T; Tzeng, C C; Cheng, T W

    2006-12-01

    Fiber reinforced plastic (FRP) composite material has widespread use in general tank, special chemical tank and body of yacht, etc. The purpose of this study is directed towards the volume reduction of non-combustible FRP by thermal plasma and recycling of vitrified slag with specific procedures. In this study, we have employed three main wastes such as, FRP, gill net and waste glass. The thermal molten process was applied to treat vitrified slag at high temperatures whereas in the post-heat treatment vitrified slags were mixed with specific additive and ground into powder form and then heat treated at high temperatures. With a two-stage heat treatment, the treated sample was generated into four crystalline phases, cristobalite, albite, anorthite and wollastonite. Fine and relatively high dense structures with desirable properties were obtained for samples treated by the two-stage heating treatment. Good physical and mechanical properties were achieved after heat treatment, and this study reveals that our results could be comparable with the commercial products.

  15. Episodic Southern Ocean Heat Loss and Its Mixed Layer Impacts Revealed by the Farthest South Multiyear Surface Flux Mooring

    NASA Astrophysics Data System (ADS)

    Ogle, S. E.; Tamsitt, V.; Josey, S. A.; Gille, S. T.; Cerovečki, I.; Talley, L. D.; Weller, R. A.

    2018-05-01

    The Ocean Observatories Initiative air-sea flux mooring deployed at 54.08°S, 89.67°W, in the southeast Pacific sector of the Southern Ocean, is the farthest south long-term open ocean flux mooring ever deployed. Mooring observations (February 2015 to August 2017) provide the first in situ quantification of annual net air-sea heat exchange from one of the prime Subantarctic Mode Water formation regions. Episodic turbulent heat loss events (reaching a daily mean net flux of -294 W/m2) generally occur when northeastward winds bring relatively cold, dry air to the mooring location, leading to large air-sea temperature and humidity differences. Wintertime heat loss events promote deep mixed layer formation that lead to Subantarctic Mode Water formation. However, these processes have strong interannual variability; a higher frequency of 2 σ and 3 σ turbulent heat loss events in winter 2015 led to deep mixed layers (>300 m), which were nonexistent in winter 2016.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This report summarizes geothermal technical assistance, R&D, and technology transfer activities of the Geo-Heat Center. It describes 95 contacts with parties during this period related to technical assistance with goethermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics, and resources. Research activities are summarized on geothermal district heating system cost evaluation and silica waste utilization project. Outreach activities include publication of a geothermal direct use Bulletin, dissemination of information, goethermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  17. DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharya, Saptarshi; Chandan, Vikas; Arya, Vijay

    In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models ofmore » individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.« less

  18. Sulfadoxine-Pyrimethamine–Based Intermittent Preventive Treatment, Bed Net Use, and Antenatal Care during Pregnancy: Demographic Trends and Impact on the Health of Newborns in the Kassena Nankana District, Northeastern Ghana

    PubMed Central

    Oduro, Abraham R.; Fryauff, David J.; Koram, Kwadwo A.; Rogers, William O.; Anto, Francis; Atuguba, Frank; Anyorigiya, Thomas; Adjuik, Martin; Ansah, Patrick; Hodgson, Abraham; Nkrumah, Francis

    2010-01-01

    Demographics and health practices of 2,232 pregnant women in rural northeastern Ghana and characteristics of their 2,279 newborns were analyzed to determine benefits associated with intermittent preventive treatment (IPTp), antenatal care, and/or bed net use during pregnancy. More than half reported bed net use, 90% reported at least two antenatal care visits, and > 82% took at least one IPTp dose of sulfadoxine-pyrimethamine. Most used a bed net and IPTp (45%) or IPTp alone (38%). Low birth weight (< 2,500 grams) characterized 18.3% of the newborns and was significantly associated with female sex, Nankam ethnicity, first-born status, and multiple births. Among newborns of primigravidae, IPTp was associated with a significantly greater birth weight, significantly fewer low birth weight newborns, improved hemoglobin levels, and less anemia. Babies of multigravidae derived no benefit to birth weight or hemoglobin level from single or multiple doses of sulfadoxine-pyrimethamine during pregnancy. No differences or benefits were seen when a bed net was the only protective factor. PMID:20595482

  19. Design principles of a simple and safe 200-MW(thermal) nuclear district heating plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goetzmann, C.; Bittermann, D.; Gobel, A.

    Kraftwerk Union AG has almost completed the development of a dedicated 200-MW(thermal) nuclear district heating plant to provide environmentally clean energy at a predictably low cost. The concept can easily be adapted to meet power requirements within the 100- to 500-MW(thermal) range. This technology is the product of the experience gained with large pressurized water reactor and boiling water reactor power plants, with respect to both plant and fuel performance. The major development task is that of achieving sufficiently low capital cost by tailoring components and systems designed for large plants to the specific requirements of district heating. These requirementsmore » are small absolute power, low temperatures and pressures, and modest load following, all of which result in the characteristics that are summarized. A fully integrated primary system with natural circulation permits a very compact reactor building containing all safety-related systems and components. Plant safety is essentially guaranteed by inherent features. The reactor containment is tightly fitted around the reactor pressure vessel in such a way that, in the event of any postulated coolant leak, the core cannot become uncovered, even temporarily. Shutdown is assured by gravity drop of the control rods mounted above the core. Decay heat is removed from the core by means of natural circulation via dedicated intermediate circuits of external aircoolers.« less

  20. Drivers of Arctic Ocean warming in CMIP5 models

    NASA Astrophysics Data System (ADS)

    Burgard, Clara; Notz, Dirk

    2017-05-01

    We investigate changes in the Arctic Ocean energy budget simulated by 26 general circulation models from the Coupled Model Intercomparison Project Phase 5 framework. Our goal is to understand whether the Arctic Ocean warming between 1961 and 2099 is primarily driven by changes in the net atmospheric surface flux or by changes in the meridional oceanic heat flux. We find that the simulated Arctic Ocean warming is driven by positive anomalies in the net atmospheric surface flux in 11 models, by positive anomalies in the meridional oceanic heat flux in 11 models, and by positive anomalies in both energy fluxes in four models. The different behaviors are mainly characterized by the different changes in meridional oceanic heat flux that lead to different changes in the turbulent heat loss to the atmosphere. The multimodel ensemble mean is hence not representative of a consensus across the models in Arctic climate projections.

  1. Micrometeorological, evapotranspiration, and soil-moisture data at the Amargosa Desert Research site in Nye County near Beatty, Nevada, 2006-11

    USGS Publications Warehouse

    Arthur, Jonathan M.; Johnson, Michael J.; Mayers, C. Justin; Andraski, Brian J.

    2012-11-13

    This report describes micrometeorological, evapotranspiration, and soil-moisture data collected since 2006 at the Amargosa Desert Research Site adjacent to a low-level radio-active waste and hazardous chemical waste facility near Beatty, Nevada. Micrometeorological data include precipitation, solar radiation, net radiation, air temperature, relative humidity, saturated and ambient vapor pressure, wind speed and direction, barometric pressure, near-surface soil temperature, soil-heat flux, and soil-water content. Evapotranspiration (ET) data include latent-heat flux, sensible-heat flux, net radiation, soil-heat flux, soil temperature, air temperature, vapor pressure, and other principal energy-budget data. Soil-moisture data include periodic measurements of volumetric water-content at experimental sites that represent vegetated native soil, devegetated native soil, and simulated waste disposal trenches - maximum measurement depths range from 5.25 to 29.25 meters. All data are compiled in electronic spreadsheets that are included with this report.

  2. Radiant Heat Transfer Between Nongray Parallel Plates of Tungsten

    NASA Technical Reports Server (NTRS)

    Branstetter, J. Robert

    1961-01-01

    Net radiant heat flow between two infinite, parallel, tungsten plates was computed by summing the monochromatic energy exchange; the results are graphically presented as a function of the temperatures of the two surfaces. In general these fluxes range from approximately a to 25 percent greater than the results of gray-body computations based on the same emissivity data. The selection of spectral emissivity data and the computational procedure are discussed. The present analytical procedure is so arranged that, as spectral emissivity data for a material become available, these data can be readily introduced into the NASA data-reduction equipment, which has been programmed to compute the net heat flux for the particular geometry and basic assumptions cited in the text. Nongray-body computational techniques for determining radiant heat flux appear practical provided the combination of select spectral emissivity data and the proper mechanized data-reduction equipment are brought to bear on the problem.

  3. District Heating Systems Performance Analyses. Heat Energy Tariff

    NASA Astrophysics Data System (ADS)

    Ziemele, Jelena; Vigants, Girts; Vitolins, Valdis; Blumberga, Dagnija; Veidenbergs, Ivars

    2014-12-01

    The paper addresses an important element of the European energy sector: the evaluation of district heating (DH) system operations from the standpoint of increasing energy efficiency and increasing the use of renewable energy resources. This has been done by developing a new methodology for the evaluation of the heat tariff. The paper presents an algorithm of this methodology, which includes not only a data base and calculation equation systems, but also an integrated multi-criteria analysis module using MADM/MCDM (Multi-Attribute Decision Making / Multi-Criteria Decision Making) based on TOPSIS (Technique for Order Performance by Similarity to Ideal Solution). The results of the multi-criteria analysis are used to set the tariff benchmarks. The evaluation methodology has been tested for Latvian heat tariffs, and the obtained results show that only half of heating companies reach a benchmark value equal to 0.5 for the efficiency closeness to the ideal solution indicator. This means that the proposed evaluation methodology would not only allow companies to determine how they perform with regard to the proposed benchmark, but also to identify their need to restructure so that they may reach the level of a low-carbon business.

  4. Water flow and energy balance for a tropical dry semideciduous forest

    NASA Astrophysics Data System (ADS)

    Andrade, J. L.; Garruña-Hernandez, R.; Leon-Palomo, M.; Us-Santamaria, R.; Sima, J. L.

    2013-05-01

    Tropical forests cool down locally because increase water evaporation from the soil to the atmosphere, reduce albedo and help forming clouds that reflect solar radiation back to the atmosphere; this, aligned to the carbon catchment, increase forests value. We will present an estimation of the sap flow and energy balance for the tropical dry semideciduous forest at Kiuic, Yucatan, Mexico during a year. We use a meteorological tower equipped with a rain gauge, temperature and relative humidity, heat flow plates, thermocouples and volumetric soil water content. We recorded net radiation and soil heat flux and estimated sensible heat and latent heat. Besides, we estimated latent heat by measuring sap flow directly in tres using disispation constant heat probes during the rainy season. Results show the influence of the seasonality on net radiation, air temperatura and vapor pressure deficit, because during the dry season his variables were higher and with more duation than during the rainy and early dry season. Sap flow was different for trees belonging to the family Fabaceae compared to trees from other families.

  5. An inter-comparison of surface energy flux measurement systems used during FIFE, 1987

    NASA Technical Reports Server (NTRS)

    Nie, D.; Kanemasu, E. T.; Fritschen, L. J.; Weaver, H.; Smith, E. A.; Verma, S. B.; Field, R. T.; Kustas, W.; Stewart, J. B.

    1990-01-01

    During the first International Satellite Land Surface Climatology Program Field Experiment (FIFE-87), surface energy fluxes were measured at 22 flux sites by nine groups of scientists using different measuring systems. A rover Bowen ratio station was taken to nearly all the flux stations to serve as a reference for estimating the instrument related differences. The rover system was installed within a few meters from the host instrument of a site. Net radiation, Bowen ratio, and latent heat fluxes were compared between the rover and the host for the stations visited. Linear regression analysis was used to examine the relationship between rover measurements and host measurements. These inter-comparisons are needed to examine the influence of instrumentation on measurement uncertainty. Highly significant effects of instrument type were detected from these comparisons. Instruments of the same type showed average differences of less than 5 percent for net radiation, 10 percent for Bowen ratio, and 6 percent for latent heat flux. The corresponding average differences for different types of instruments can be up to 10, 30, and 20 percent respectively. The Didcot net radiometer gave higher net radiation while the Swissteco type showed lower values, as compared to the corrected REBS model. The 4-way components methed and the Thornswaite type give similar values to the REBS. The SERBS type Bowen ratio systems exhibit slightly lower Bowen ratios and thus higher latent heat fluxes, compared to the AZET systems. Eddy correlation systems showed slightly lower latent heat flux in comparison to the Bowen ratio systems.

  6. Institutional and financial guide to geothermal district heating, serial no. 2

    NASA Astrophysics Data System (ADS)

    1982-03-01

    General planning considerations which affect nearly every community are reviewed, and alternative operating structures which are available to communities are reviewed, including local governments, nonprofit cooperatives, private enterprises, and joint ventures. The financing options available to publicly-owned and privately-owned district heating systems are then summarized. The geothermal production and distribution activities most appropriate to each type of operating structure are reviewed, along with typical equity and debt funding sources. The tax advantages for private developers are described, as are the issues of customer contracts and service prices, and customer retrofit financing. The treatment is limited to an introductory overview.

  7. Reaching and Remediating "Grey-Area" Middle School Students

    ERIC Educational Resources Information Center

    Jorgenson, Olaf; Smolkovich, Greg E.

    2004-01-01

    This article presents a framework for school administrators developed by Mesa Unified School district used in identifying and assisting the subtly struggling adolescents. Mesa's "safety net" approach targets middle grades students in the midst of their formative, pre-high school experience. Here, it is stated that the first step to identify a…

  8. Asymptomatic malaria parasitaemia using rapid diagnostic test in unbooked pregnant women in rural Ondo-south district, Nigeria.

    PubMed

    Nwaneri, D U; Adeleye, O A; Ande, A B

    2013-03-01

    Malaria is a major contributor of maternal and peri-natal morbidity and mortality. The disease may be asymptomatic despite sequestration of parasitized red blood cells in the placental micro-circulation with antecedent complications. In such condition, it may also be difficult to identify the malaria parasite by the peripheral blood film microscopy, thus the need for use of simple but reliable tool for malaria parasite diagnosis. To determine the prevalence of asymptomatic malaria parasitaemia using the Rapid Diagnostic Test in pregnant unbooked women seen in a primary health centre during a malaria control campaign programme in rural Ondo-south, District Nigeria. Prevalence of asymptomatic malaria parasitaemia was 25.9%. Only 3 (3.5%) of the 85 women had the long lasting insecticide-treated nets. There was no significant association between malaria parasitaemia, and the age group, parity and gestation age. Given the high prevalence of asymptomatic malaria in pregnancy, routine screening for malaria at booking and scaling-up of other malaria control strategies such as the use of long lasting insecticidal-treated nets and intermittent preventive therapy for pregnant women are recommended.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuznetsov, Yury N.

    The co-generation nuclear power plant (CNPP) producing electricity and district heating heat is planned to be constructed in Archangelsk Region of Russia. Following the 'Letter of Intent' signed by Governor of Archangelsk region and by Minister of the Russian Federation for atomic energy the feasibility study of the Project has been done. The NPP will be based on the four co-generation nuclear power units with the Russian VK-300 SBWR. The innovative passive VK-300 reactor facility has been designed on the basis of well-established nuclear technologies, proven major components, the operating experience of the prototype VK-50 reactor in RIAR, Dimitrovgrad, andmore » the experience in designing such reactors as SBWR (GE) and SWR-1000 (Siemens). The CNPP's total power is planned to be 1000 MW(e) and district-heating heat production capacity 1600 Gcal/h. A detailed description of the results of the feasibility study is presented in the report. The results of the feasibility study have shown that the Archangelsk CGNP is feasible in terms of engineering, economics and production. (authors)« less

  10. RESTful M2M Gateway for Remote Wireless Monitoring for District Central Heating Networks

    PubMed Central

    Cheng, Bo; Wei, Zesan

    2014-01-01

    In recent years, the increased interest in energy conservation and environmental protection, combined with the development of modern communication and computer technology, has resulted in the replacement of distributed heating by central heating in urban areas. This paper proposes a Representational State Transfer (REST) Machine-to-Machine (M2M) gateway for wireless remote monitoring for a district central heating network. In particular, we focus on the resource-oriented RESTful M2M gateway architecture, and present an uniform devices abstraction approach based on Open Service Gateway Initiative (OSGi) technology, and implement the resource mapping mechanism between resource address mapping mechanism between RESTful resources and the physical sensor devices, and present the buffer queue combined with polling method to implement the data scheduling and Quality of Service (QoS) guarantee, and also give the RESTful M2M gateway open service Application Programming Interface (API) set. The performance has been measured and analyzed. Finally, the conclusions and future work are presented. PMID:25436650

  11. RESTful M2M gateway for remote wireless monitoring for district central heating networks.

    PubMed

    Cheng, Bo; Wei, Zesan

    2014-11-27

    In recent years, the increased interest in energy conservation and environmental protection, combined with the development of modern communication and computer technology, has resulted in the replacement of distributed heating by central heating in urban areas. This paper proposes a Representational State Transfer (REST) Machine-to-Machine (M2M) gateway for wireless remote monitoring for a district central heating network. In particular, we focus on the resource-oriented RESTful M2M gateway architecture, and present an uniform devices abstraction approach based on Open Service Gateway Initiative (OSGi) technology, and implement the resource mapping mechanism between resource address mapping mechanism between RESTful resources and the physical sensor devices, and present the buffer queue combined with polling method to implement the data scheduling and Quality of Service (QoS) guarantee, and also give the RESTful M2M gateway open service Application Programming Interface (API) set. The performance has been measured and analyzed. Finally, the conclusions and future work are presented.

  12. Feeling the Heat

    ERIC Educational Resources Information Center

    Stroud, Sara

    2010-01-01

    A few years ago, when the Irvine Unified School District (USD) was trying to get a handle on sky-high energy spending, it looked to the sun, which is virtually always in view given the district's locale: Orange County, California. Flash forward to 2010, and Irvine USD is in the midst of implementing what it says is the most comprehensive K-12…

  13. Long lasting insecticidal net use and its associated factors in Limmu Seka District, South West Ethiopia.

    PubMed

    Hambisa, Mitiku Teshome; Debela, Tessema; Dessie, Yadeta; Gobena, Tesfaye

    2018-01-10

    Many countries in sub-Saharan Africa, including Ethiopia, are focusing on the distribution of Long Lasting Insecticidal Nets (LLINs) to combat malaria. However, utilization of the LLIN is low when compared with LLIN possession because of various factors. This study was conducted to measure the actual LLIN usage and identify factors associated with its utilization in Limmu Seka District, South West Ethiopia. A community based cross-sectional survey was conducted among 830 households from December 25, 2011 to February 29, 2012. A total of 830 households were selected by stratified systematic sampling and surveyed. Ninety percent of those surveyed owned LLINs and 68.3% reported that someone had slept under the net on the night prior to the survey. The factors associated with LLIN usage were knowledge of the mode of malaria transmission (AOR; 0.086, 95% CI 0.03, 0.24), the preferred conical shapes of the LLIN (AOR; 1.6, 95% CI 1.31, 4.1), receiving information about their use from Health Extension Workers (HEWs) (AOR; 2.4, 95% CI 1.5, 3.9), hearing media campaigns (AOR; 3.2 95% CI 3.5, 9.2), education at a health facility (AOR; 2 95% CI 1.5, 3.9) or having a family size of three or less (AOR; 2.1, 95% CI 1.3, 3.5). Although ownership of Long Lasting Insecticidal Nets was high at 90%, the actual usage of LLIN was low, and not all family members were protected. Promoting the usage of LLINs utilization by those at most risk, especially the conical shaped ones, through intensified health education using HEWs and mass media campaigns at all health facilities, schools and communities will improve LLIN utilization.

  14. Ownership and usage of insecticide-treated bed nets after free distribution via a voucher system in two provinces of Mozambique.

    PubMed

    Macedo de Oliveira, Alexandre; Wolkon, Adam; Krishnamurthy, Ramesh; Erskine, Marcy; Crenshaw, Dana P; Roberts, Jacquelin; Saúte, Francisco

    2010-08-04

    Insecticide-treated bed nets (ITNs) are an efficacious intervention for malaria prevention. During a national immunization campaign in Mozambique, vouchers, which were to be redeemed at a later date for free ITNs, were distributed in Manica and Sofala provinces. A survey to evaluate ITN ownership and usage post-campaign was conducted. Four districts in each province and four enumeration areas (EAs) in each district were selected using probability proportional to size. Within each EA, 32 households (HHs) were selected using a simple random sample. Interviews to assess ownership and usage were conducted in each of the selected HHs using personal digital assistants. Valid interviews were completed for 947 (92.5%) (440 in Manica and 507 in Sofala) of the 1,024 selected HHs. Among participating HHs, 65.0% in Manica and 63.1% in Sofala reported that at least one child under five years of age slept in the house the previous night. HH ownership of at least one bed net of any kind was 20.6% (95% confidence interval [CI]: 7.9%-43.6%) and 35.6% (95% CI: 27.8%-44.3%) pre-campaign; and 55.1% (95% CI: 43.6%-66.1%) and 59.6 (95% CI: 42.4%-74.7%) post-campaign in Manica and Sofala, respectively. Post-campaign HH ownership of at least one ITN was 50.2% (95% CI: 41.8%-58.5%) for both provinces combined. In addition, 60.3% (95% CI: 50.6%-69.2%) of children under five years of age slept under an ITN the previous night. This ITN distribution increased bed net ownership and usage rates. Integration of ITN distribution with immunization campaigns presents an opportunity for reaching malaria control targets and should continue to be considered.

  15. Engine performance analysis and optimization of a dual-mode scramjet with varied inlet conditions

    NASA Astrophysics Data System (ADS)

    Tian, Lu; Chen, Li-Hong; Chen, Qiang; Zhong, Feng-Quan; Chang, Xin-Yu

    2016-02-01

    A dual-mode scramjet can operate in a wide range of flight conditions. Higher thrust can be generated by adopting suitable combustion modes. Based on the net thrust, an analysis and preliminary optimal design of a kerosene-fueled parameterized dual-mode scramjet at a crucial flight Mach number of 6 were investigated by using a modified quasi-one-dimensional method and simulated annealing strategy. Engine structure and heat release distributions, affecting the engine thrust, were chosen as analytical parameters for varied inlet conditions (isolator entrance Mach number: 1.5-3.5). Results show that different optimal heat release distributions and structural conditions can be obtained at five different inlet conditions. The highest net thrust of the parameterized dual-mode engine can be achieved by a subsonic combustion mode at an isolator entrance Mach number of 2.5. Additionally, the effects of heat release and scramjet structure on net thrust have been discussed. The present results and the developed analytical method can provide guidance for the design and optimization of high-performance dual-mode scramjets.

  16. Solar tower power plant using a particle-heated steam generator: Modeling and parametric study

    NASA Astrophysics Data System (ADS)

    Krüger, Michael; Bartsch, Philipp; Pointner, Harald; Zunft, Stefan

    2016-05-01

    Within the framework of the project HiTExStor II, a system model for the entire power plant consisting of volumetric air receiver, air-sand heat exchanger, sand storage system, steam generator and water-steam cycle was implemented in software "Ebsilon Professional". As a steam generator, the two technologies fluidized bed cooler and moving bed heat exchangers were considered. Physical models for the non-conventional power plant components as air- sand heat exchanger, fluidized bed coolers and moving bed heat exchanger had to be created and implemented in the simulation environment. Using the simulation model for the power plant, the individual components and subassemblies have been designed and the operating parameters were optimized in extensive parametric studies in terms of the essential degrees of freedom. The annual net electricity output for different systems was determined in annual performance calculations at a selected location (Huelva, Spain) using the optimized values for the studied parameters. The solution with moderate regenerative feed water heating has been found the most advantageous. Furthermore, the system with moving bed heat exchanger prevails over the system with fluidized bed cooler due to a 6 % higher net electricity yield.

  17. Final Report. Montpelier District Energy Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, Jessie; Motyka, Kurt; Aja, Joe

    2015-03-30

    The City of Montpelier, in collaboration with the State of Vermont, developed a central heat plant fueled with locally harvested wood-chips and a thermal energy distribution system. The project provides renewable energy to heat a complex of state buildings and a mix of commercial, private and municipal buildings in downtown Montpelier. The State of Vermont operates the central heat plant and the system to heat the connected state buildings. The City of Montpelier accepts energy from the central heat plant and operates a thermal utility to heat buildings in downtown Montpelier which elected to take heat from the system.

  18. Diagnostic calculations of the circulation in the Martian atmosphere

    NASA Technical Reports Server (NTRS)

    Santee, Michelle L.; Crisp, David

    1995-01-01

    The circulation of the Martian atmosphere during late southern summer is derived from atmospheric temperature and dust distributions retrieved from a subset of the Mariner 9 infrared interferometer spectrometer (IRIS) thermal emission spectra (LS = 343-348 deg) (Santee and Crisp, 1933). Zonal-mean zonal winds are calculated by assuming gradient wind balance and zero surface zonal wind. Both hemispheres have intense midlatitude westerly jets with velocities of 80-90 m/s near 50 km; in the southern tropics the winds are easterly with velocities of 40 m/s near 50 km. The net effect of the zonal-mean meridional circulation and large-scale waves can be approximated by the diabatic ciculation, which is defined from the atmospheric thermal structure and net radiative heating rates. The radiative transfer model described by Crisp (1990) and Santee (1993) is used to compute solar heating and thermal cooling rates from diurnal averages of the retrieved IRIS temperature and dust distributions. At pressures below 4 mbar, there are large net radiative heating rates (up to 5 K/d) in the equatorial region and large net radiative cooling rates (up to 12 K/d) in the polar regions. These net radiative heating rates are used in a diagnostic stream function model which solves for the meridonal and vertical components of the diabatic circulation simultaneously. We find a two cell circulation, with rising motion over the equator, poleward flow in both hemispheres, sinking motion over both polar regions, and return flow in the lowest atmospheric levels. The maximum poleward velocity is 3 m/s in the tropics at approximately 55 km altitude, and the maximum vertical velocity is 2.5 cm/s downward over the north pole at approximately 60 km altitude. If these large transport rates are sustained for an entire season, the Martian atmosphere above the 1-mbar level is overturned in about 38 days. This diabatic circulation is qualitatively similar to the terrestial diabatic circulation at the comparable season, but is more vigorous.

  19. Diagnostic calculations of the circulation in the Martian atmosphere

    NASA Astrophysics Data System (ADS)

    Santee, Michelle L.; Crisp, David

    1995-03-01

    The circulation of the Martian atmosphere during late southern summer is derived from atmospheric temperature and dust distributions retrieved from a subset of the Mariner 9 infrared interferometer spectrometer (IRIS) thermal emission spectra (LS = 343-348 deg) (Santee and Crisp, 1933). Zonal-mean zonal winds are calculated by assuming gradient wind balance and zero surface zonal wind. Both hemispheres have intense midlatitude westerly jets with velocities of 80-90 m/s near 50 km; in the southern tropics the winds are easterly with velocities of 40 m/s near 50 km. The net effect of the zonal-mean meridional circulation and large-scale waves can be approximated by the diabatic ciculation, which is defined from the atmospheric thermal structure and net radiative heating rates. The radiative transfer model described by Crisp (1990) and Santee (1993) is used to compute solar heating and thermal cooling rates from diurnal averages of the retrieved IRIS temperature and dust distributions. At pressures below 4 mbar, there are large net radiative heating rates (up to 5 K/d) in the equatorial region and large net radiative cooling rates (up to 12 K/d) in the polar regions. These net radiative heating rates are used in a diagnostic stream function model which solves for the meridonal and vertical components of the diabatic circulation simultaneously. We find a two cell circulation, with rising motion over the equator, poleward flow in both hemispheres, sinking motion over both polar regions, and return flow in the lowest atmospheric levels. The maximum poleward velocity is 3 m/s in the tropics at approximately 55 km altitude, and the maximum vertical velocity is 2.5 cm/s downward over the north pole at approximately 60 km altitude. If these large transport rates are sustained for an entire season, the Martian atmosphere above the 1-mbar level is overturned in about 38 days. This diabatic circulation is qualitatively similar to the terrestial diabatic circulation at the comparable season, but is more vigorous.

  20. Diagnostic calculations of the circulation in the Martian atmosphere

    NASA Technical Reports Server (NTRS)

    Santee, Michelle L.; Crisp, David

    1995-01-01

    The circulation of the Martian atmosphere during late southern summer is derived from atmospheric temperature and dust distributions retrieved from a subset of the Mariner 9 infrared interferometer spectrometer (IRIS) thermal emission spectra (L(sub s) = 343-348 deg). Zonal-mean zonal winds are calculated by assuming gradient wind balance and zero surface zonal wind. Both hemispheres have intense midlatitude westerly jets with velocities of 80-90 m/s near 50 km; in the southern tropics the winds are easterly with velocities of 40 m/s near 50 km. The net effect of the zonal mean meridional circulation and large-scale waves can be approximated by the diabatic circulation, which is defined from the atmospheric thermal structure and net radiative heating rates. The radiative transfer model described by Crisp (1990) and Santee (1993) is used to compute solar heating and thermal cooling rates from diurnal averages of the retrieved IRIS temperature and dust distributions. At pressures below 4 mbar, there are large net radiative heating rates (up to 5 K/d) in the equatorial region and large net radiative cooling rates (up to 12 K/d) in the polar regions. These net radiative heating rates are used in a diagnostic stream function model which solves for the meridional and vertical components of the diabatic circulation simultaneously. We find a two-cell circulation, with rising motion over the equator, poleward flow in both hemispheres, sinking motion over both polar regions, and return flow in the lowest atmospheric levels. The maximum poleward velocity is 3 m/s in the tropics at approx. 55 km altitude, and the maximum vertical velocity is 2.5 cm/s downward over the north pole at approx. 60 km altitude. If these large transport rates are sustained for an entire season, the Martian atmosphere above the 1-mbar level is overturned in about 38 days. This diabatic circulation is qualitatively similar to the terrestrial diabatic circulation at the comparable season, but is more vigorous.

  1. Multidecadal-scale adjustment of the ocean mixed layer heat budget in the tropics: examining ocean reanalyses

    NASA Astrophysics Data System (ADS)

    Cook, Kerry H.; Vizy, Edward K.; Sun, Xiaoming

    2018-03-01

    Distributions of ocean mixed layer temperature trends and trends in the net heat flux from the atmosphere differ, indicating the important role of the transport of heat within the ocean for determining temperature trends. Annual-mean, linear trends in the components of the tropical ocean mixed layer heat budget for 1980-2015 are diagnosed in 4 ocean reanalyses to improve our physical understanding of multidecadal-scale SST trends. The well-known temperature trend in the tropical Pacific, with cooling in the east and warming in the west, is reproduced in each reanalysis with high statistical significance. Cooling in the east is associated with negative trends in the net heat flux from the atmosphere and enhanced equatorial upwelling related to a strengthening of the subtropical cells. Negative trends in the net heat flux also occur in the western tropical Pacific, but advective warming associated with a strengthening and shoaling of the equatorial undercurrent overwhelms these negative trends. The strengthening of the equatorial undercurrent is consistent with enhanced easterly wind stress, which is applied to the ocean reanalyses, and differential sea level trends that enhance the negative zonal height gradient across the Pacific. The Pacific North Equatorial countercurrent is also strengthening in all 4 reanalyses in association with a strengthening of the sea level trough at 10°N in the central and eastern Pacific. All 4 ocean reanalyses produce warming of 0.1-0.3 K/decade in the North Atlantic with statistical significance levels ranging from below 90-99%. The Atlantic is similar to the Pacific in having the equatorial undercurrent strengthening, but indications of shoaling are less consistent in the reanalyses and the North Equatorial Countercurrent in the Atlantic is not strengthening. Large-scale ocean mixed layer warming trends in the Indian Ocean in the reanalyses are interrupted by some regional cooling close to the equator. Net surface heat flux trends are mostly negative, indicating increasing heat fluxes from the ocean to the atmosphere. Wind stress trends applied to the ocean reanalyses are weak, but trends in the Indian Ocean equatorial undercurrent are strong. Since the Indian monsoon climate introduces strong seasonality, the annual analysis may not be adequate for studying physical processes in this ocean basin.

  2. Net-Zero Building Technologies Create Substantial Energy Savings -

    Science.gov Websites

    -by-step information for decision making around net-zero energy building technologies. The past three improved insulation, windows, and heating and cooling systems. Despite these strides, energy use by energy building methodologies and technologies during a tour of the RSF's rooftop PV system. Photo by

  3. Mineralizing urban net-zero water treatment: Phase II field results and design recommendations

    EPA Science Inventory

    Net-zero water (NZW) systems, or water management systems achieving high recycling rates and low residuals generation so as to avoid water import and export, can also conserve energy used to heat and convey water, while economically restoring local eco-hydrology. However, design ...

  4. Persistent 'hotspots' of lymphatic filariasis microfilaraemia despite 14 years of mass drug administration in Ghana.

    PubMed

    Biritwum, Nana-Kwadwo; Yikpotey, Paul; Marfo, Benjamin K; Odoom, Samuel; Mensah, Ernest O; Asiedu, Odame; Alomatu, Bright; Hervie, Edward T; Yeboah, Abednego; Ade, Serge; Hinderaker, Sven G; Reid, Anthony; Takarinda, Kudakwashe C; Koudou, Benjamin; Koroma, Joseph B

    2016-12-01

    Among the 216 districts in Ghana, 98 were declared endemic for lymphatic filariasis in 1999 after mapping. Pursuing the goal of elimination, WHO recommends annual treatment using mass drugs administration (MDA) for at least 5 years. MDA was started in the country in 2001 and reached national coverage in 2006. By 2014, 69 districts had 'stopped-MDA' (after passing the transmission assessment survey) while 29 others remained with persistent microfilaraemia (mf) prevalence (≥1%) despite more than 11 years of MDA and were classified as 'hotspots'. An ecological study was carried out to compare baseline mf prevalence and anti-microfilaria interventions between hotspot and stopped-MDA districts. Baseline mf prevalence was significantly higher in hotspots than stopped-MDA districts (p<0.001). After three years of MDA, there was a significant decrease in mf prevalence in hotspot districts, but it was still higher than in stopped-MDA districts. The number of MDA rounds was slightly higher in hotspot districts (p<0.001), but there were no differences in coverage of MDA or long-lasting-insecticide-treated nets. The main difference in hotspots and stopped-MDA districts was a high baseline mf prevalence. This finding indicates that the recommended 5-6 rounds annual treatment may not achieve interruption of transmission. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Southern Ocean Seasonal Net Production from Satellite, Atmosphere, and Ocean Data Sets

    NASA Technical Reports Server (NTRS)

    Keeling, Ralph F.; Campbell, J. (Technical Monitor)

    2002-01-01

    A new climatology of monthly air-sea O2 flux was developed using the net air-sea heat flux as a template for spatial and temporal interpolation of sparse hydrographic data. The climatology improves upon the previous climatology of Najjar and Keeling in the Southern Hemisphere, where the heat-based approach helps to overcome limitations due to sparse data coverage. The climatology is used to make comparisons with productivity derived from CZCS images. The climatology is also used in support of an investigation of the plausible impact of recent global warming an oceanic O2 inventories.

  6. Innovative Corrosion-Resistant Coatings for Heat Distribution Piping at Fort Jackson

    DTIC Science & Technology

    2007-06-01

    installations are served by district heat distribution sys- tems (HDSs) that provide space heating and hot water to the facilities. HDSs are large, complex...corrosive to exposed steel. Furthermore, water tends to infiltrate the manhole from outside or though pinhole leaks in pipes. When water collects in the man...energized. A typical HDS services a number of installa- tion customers all year for both space heating and domestic hot water . Scheduled maintenance is

  7. Description and operation of Haakon School geothermal heating system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Childs, F.W.; Kirol, L.D.; Sanders, R.D.

    1997-12-01

    Haakon School is located in the city of Philip, near the Badlands National Park in the southwest quadrant of South Dakota. The town overlies the Madison Formation which is a large-area aquifer. The aquifer has a demonstrated capability to produce geothermal water. A system to tap this potential and heat the Haakon School District buildings in Philip has been in operation since November 1980. Five school buildings having a total area of 44,000 ft{sup 2} (4088 ft{sup 2}) are heated with 157{degrees}F (69{degrees}C) water. A single well provides water at a maximum artesian flow of 340 gpm (21.5 L/s), whichmore » more than meets the heat demand of the school buildings. Eight buildings in the Philip business district utilize geothermal fluid discharged from the school for space heating. During the 1980-81 heating season, these buildings obtained 75% to 90% of their heat from geothermal fluid. Peak heat delivery of the system is 5.5 million Btu/h (1.61. MJ/s), with an annual energy delivery of 9.5 billion Btu (10 TJ). The geothermal system has operated nearly problem free with the exception of the equipment to remove Radium-226 from the spent fluid. Barium chloride is added to the water to precipitate sulfates containing the radium. Accumulation of precipitates in piping has caused some operational problems.« less

  8. Involvement of respiratory processes in the transient knockout of net CO2 uptake in Mimosa pudica upon heat stimulation.

    PubMed

    Lautner, Silke; Stummer, Michaela; Matyssek, Rainer; Fromm, Jörg; Grams, Thorsten E E

    2014-01-01

    Leaf photosynthesis of the sensitive plant Mimosa pudica displays a transient knockout in response to electrical signals induced by heat stimulation. This study aims at clarifying the underlying mechanisms, in particular, the involvement of respiration. To this end, leaf gas exchange and light reactions of photosynthesis were assessed under atmospheric conditions largely eliminating photorespiration by either elevated atmospheric CO2 or lowered O2 concentration (i.e. 2000 μmol mol(-1) or 1%, respectively). In addition, leaf gas exchange was studied in the absence of light. Under darkness, heat stimulation caused a transient increase of respiratory CO2 release simultaneously with stomatal opening, hence reflecting direct involvement of respiratory stimulation in the drop of the net CO2 uptake rate. However, persistence of the transient decline in net CO2 uptake rate under illumination and elevated CO2 or 1% O2 makes it unlikely that photorespiration is the metabolic origin of the respiratory CO2 release. In conclusion, the transient knockout of net CO2 uptake is at least partially attributed to an increased CO2 release through mitochondrial respiration as stimulated by electrical signals. Putative CO2 limitation of Rubisco due to decreased activity of carbonic anhydrase was ruled out as the photosynthesis effect was not prevented by elevated CO2 . © 2013 John Wiley & Sons Ltd.

  9. Heat pump concepts for nZEB Technology developments, design tools and testing of heat pump systems for nZEB in the USA: Country report IEA HPT Annex 40 Task 2, Task 3 and Task 4 of the USA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D.; Payne, W. Vance; Ling, Jiazhen

    The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage formore » several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.« less

  10. Design Calculation Procedure for Passive Solar Houses at Navy Installations in Warm California Climates. Volume V.

    DTIC Science & Technology

    1981-10-01

    Storage Locations . . .. 7 2.3 Heat Transfer Mechanisms of Thermal Storage Walls ......... 11 2.4 Heating of Living Space with Solar Greenhouse ...12 2.5 Schematic of North-Side Greenhouse Retrofit ........... . .. 12 2.6 The Roof Pond in Warm Climate . . . . . . . . . . . . . . . . 14 2.7...Profile .......... ... 47 5 Calculation of Solar Heating Contribution ............. .. 51 5A Adjusted Net Solar Greenhouse Heat Gain

  11. Energy Sources and Systems Analysis: 40 South Lincoln Redevelopment District (Full Report)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-08-01

    This report presents the results of a case study to analyze district energy systems for their potential use in a project that involves redeveloping 270 units of existing public housing, along with other nearby sites. When complete, the redevelopment project will encompass more than 900 mixed-income residential units, commercial and retail properties, and open space. The analysis estimated the hourly heating, cooling, domestic hot water, and electric loads required by the community; investigated potential district system technologies to meet those needs; and researched available fuel sources to power such systems.

  12. Potentiometric surface of the Floridan Aquifer and its use in management of water resources, St. Johns River Water Management District, Florida

    USGS Publications Warehouse

    Rodis, Harry George; Munch, D.A.

    1983-01-01

    The Floridan aquifer supplies most of the fresh groundwater for municipal, industrial, and agricultural uses within the 12,400 sq mi St. Johns River Water Management District. Because of the growing demand for water and the variation in rainfall, resource managers need timely information on short-term and long-term changes in the availability of fresh water. The purpose of this report is to explain potentiometric surface maps and their value in assessing the resource, particularly during drought conditions. The Floridan aquifer is recharged by rainfall falling directly on the outcrop of the aquifer, and, where the aquifer is overlain by the surficial aquifer with the water table above the potentiometric surface of the Floridan, by water infiltrating downward from the overlying surficial aquifer. Water is discharged by pumping and free-flowing wells, springflow, and upward leakage into overlying formations, streams, and lakes or into the ocean. Fluctuations in the potentiometric surface reflect net gains (recharge) or losses (discharge) of water stored in the aquifer. Net gains occur during the wet season (June through September) when recharge exceeds discharge and causes the potentiometric surface to rise in most places. Net losses in storage, and declines in the potentiometric surface, follow during the dry season (October through May) when discharge exceeds recharge. Seasonal changes in the potentiometric surface, based on a 2-yr average of water level measurements during May and September 1977, and May and September 1978, are illustrated. Two of the greater long-term declines in the potentiometric surface have occurred in the growing metropolitan areas of Jacksonville and Orlando-Winter Park, the two largest public suppliers of water in the Water Management District. Municipal pumpage increased in Jacksonville from 37 million gallons per day (mgd) in 1961 to 56 mgd in 1980. The increased pumpage and a deficiency in rainfall of 15.8 inches contributed to a decline in the potentiometric surface of as much as 15 ft. Orlando-Winter Park municipal pumpage increasing from 27 mgd in 1961 to 62 mgd in 1980. The periodic preparation of maps showing changes in the potentiometric surface of the aquifer provide the best base information for both short-term and long-term management of the water resources in the St. Johns River Water Management District. (Lantz-PTT)

  13. Relationship between vaccine vial monitors and cold chain infrastructure in a rural district of India.

    PubMed

    Samant, Y; Lanjewar, H; Parker, L; Block, D; Stein, B; Tomar, G

    2007-01-01

    The potency of oral polio vaccine (OPV), a heat-labile vaccine, is preserved by the cold chain. The Vaccine Vial Monitor, a heat-sensitive label, is critical to the monitoring and maintenance of the cold chain. This study was conducted to evaluate the relationship between the adequacy of cold chain infrastructure and the proper use of Vaccine Vial Monitor in a rural district of India. Forty-six health centers in a rural district were included in our evaluation of the cold chain equipment and the Vaccine Vial Monitors. Cold chain equipment and vaccine vials within each health center were evaluated for adherence to WHO cold chain maintenance protocols and the Vaccine Vial Monitor stage, respectively. Among the 46 health centers, Vaccine Vial Monitor stage I was found at 58% of the health centers, 33% of the health centers reported stage II and 9% reported a stage III, indicating weaknesses in the cold chain mechanism Cold chain for the OPV was not adequately maintained at primary and sub-health centers in this rural district. Well maintained ice packs and vaccine carriers will help ensure delivery and availability of a safe and potent vaccine to children in rural areas of India.

  14. Improving malaria treatment and prevention in India by aiding district managers to manage their programmes with local information: a trial assessing the impact of Lot Quality Assurance Sampling on programme outcomes.

    PubMed

    Valadez, Joseph J; Devkota, Baburam; Pradhan, Madan Mohan; Meherda, Pramod; Sonal, G S; Dhariwal, Akshay; Davis, Rosemary

    2014-10-01

    This paper reports the first trial of Lot Quality Assurance Sampling (LQAS) assessing associations between access to LQAS data and subsequent improvements in district programming. This trial concerns India's approach to addressing an increase in malaria-attributable deaths by training community health workers to diagnose, treat and prevent malaria, while using LQAS to monitor sub-district performance and make programme improvements. The Ministry of Health introduced LQAS into four matched high malaria burden districts (Annual Parasite Incidence >5) (N > 5 million). In each sub-district, we sampled four populations in three 6-monthly surveys: households, children <5 years, people with fever in the last 2 weeks and community health workers. In three districts, trained local staff collected, analysed and used data for programme management; in one control district, non-local staff collected data and did not disseminate results. For eight indicators, we calculated the change in proportion from survey one to three and used a Difference-in-Differences test to compare the relative change between intervention and control districts. Coverage increased from survey one to three for 24 of 32 comparisons. Difference-in-Differences tests revealed that intervention districts exhibited significantly greater change in four of six vertical strategies (insecticide treated bed-nets and indoor residual spraying), one of six treatment-seeking behaviours and four of 12 health worker capacity indicators. The control district displayed greater improvement than two intervention districts for one health worker capacity indicator. One district with poor management did not improve. In this study, LQAS results appeared to support district managers to increase coverage in underperforming areas, especially for vertical strategies in the presence of diligent managers. © 2014 The Authors. Tropical Medicine & International Health published by John Wiley & Sons Ltd.

  15. Budget impact analysis of trastuzumab in early breast cancer: a hospital district perspective.

    PubMed

    Purmonen, Timo T; Auvinen, Päivi K; Martikainen, Janne A

    2010-04-01

    Adjuvant trastuzumab is widely used in HER2-positive (HER2+) early breast cancer, and despite its cost-effectiveness, it causes substantial costs for health care. The purpose of the study was to develop a tool for estimating the budget impact of new cancer treatments. With this tool, we were able to estimate the budget impact of adjuvant trastuzumab, as well as the probability of staying within a given budget constraint. The created model-based evaluation tool was used to explore the budget impact of trastuzumab in early breast cancer in a single Finnish hospital district with 250,000 inhabitants. The used model took into account the number of patients, HER2+ prevalence, length and cost of treatment, and the effectiveness of the therapy. Probabilistic sensitivity analysis and alternative case scenarios were performed to ensure the robustness of the results. Introduction of adjuvant trastuzumab caused substantial costs for a relatively small hospital district. In base-case analysis the 4-year net budget impact was 1.3 million euro. The trastuzumab acquisition costs were partially offset by the reduction in costs associated with the treatment of cancer recurrence and metastatic disease. Budget impact analyses provide important information about the overall economic impact of new treatments, and thus offer complementary information to cost-effectiveness analyses. Inclusion of treatment outcomes and probabilistic sensitivity analysis provides more realistic estimates of the net budget impact. The length of trastuzumab treatment has a strong effect on the budget impact.

  16. Enceladus is not in Steady State

    NASA Astrophysics Data System (ADS)

    Cheunchitra, T.; Stevenson, D. J.

    2016-12-01

    Libration data tell us there is a global ocean. Topography and gravity tell us that there is substantial compensation at degree 2, meaning that the underside of the ice shell must have topography. This topography will decay, typically on a timescale of order a million years (fortuitously similar to thermal diffusion times through the ice shell), by viscous lateral flow of the ice. This could in principle be compensated in steady state by net melting beneath the poles and a compensating net freezing at the equator. In that model, the ice shell beneath the poles is partially melted with water being continuously produced and percolating to the base (or expelled if there are cracks, as at the South Pole). We have modeled this without an a priori assumption about the strength of tidal heating. We find that even if the tidal heating is zero on average around the equator, then the latent heat release from the required freezing can only be accommodated in steady state if the ice shell is 18km. The ice thickness must be even less at the poles in order to satisfy gravity and topography. Moreover, there must then be substantial tidal heating at the poles and it is physically unreasonable to have the volumetric tidal heating at the equator be enormously less than at the North Pole. For example, if the volumetric tidal heating at the equator is on average one quarter of that at the North Pole then marginal consistency with gravity and topography may be possible for a mean ice thickness at the equator of 12km. The global heat flow may exceed 40GW, much higher than the detectable IR excess (the observed south polar tiger stripe heat flow). Recent work (Fuller et al.) admits orbital evolutions with large heat flow at least for a recent part of the orbital history. However, this thin shell steady state model has difficulty reconciling observed gravity and topography as well as the libration data. We conclude that it is unlikely that Enceladus has no net melting or freezing. The ice shell can be thicker on average if there is net freezing at present but in that case it is difficult to explain the observed topography and gravity. A more likely scenario is that Enceladus has more melting beneath the poles than the current freezing (if any) beneath the equator. In that non-steady state model, the current ice thickness can be compatible with all current data.

  17. Casting a Statewide Strategic Performance Net: Interlaced Data and Responsive Supports

    ERIC Educational Resources Information Center

    Layland, Allison; Redding, Sam

    2017-01-01

    The pivot point for educational change is now firmly placed with the district, rebalancing the position of the state and the school relative to the local education agency (LEA). The state education agency (SEA) has been shifting its emphasis for decades, from a compliance-focused authority to a change agent equipped with systems, processes,…

  18. 75 FR 20846 - Notice of Suspension and Initiation of Debarment Proceedings; Schools and Libraries Universal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... admitted that you and others devised schemes to defraud school districts and the E-Rate program by having..., your conspirators, and your company, primarily DeltaNet, Inc.\\6\\ In furtherance of the schemes, you...\\ Ultimately, your conspiracy was comprised of two closely related schemes that affected at least thirteen...

  19. 75 FR 20844 - Notice of Suspension and Initiation of Debarment Proceedings; Schools and Libraries Universal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... schemes to defraud school districts and the E-Rate program by having your co-conspirators steer E-rate..., primarily DeltaNet, Inc.\\6\\ In furtherance of the schemes, you submitted misleading, fraudulent and false... comprised of two closely related schemes that affected at least thirteen different schools in eight...

  20. Heat stress incident prevalence and tennis matchplay performance at the Australian Open.

    PubMed

    Smith, Matthew T; Reid, Machar; Kovalchik, Stephanie; Woods, Tim O; Duffield, Rob

    2018-05-01

    To examine the association of wet bulb globe temperature (WBGT) with the occurrence of heat-related incidents and changes in behavioural and matchplay characteristics in men's Grand Slam tennis. On-court calls for trainers, doctors, cooling devices and water, post-match medical consults and matchplay characteristic data were collected from 360 Australian Open matches (first 4 rounds 2014-2016). Data were referenced against estimated WBGT and categorised into standard zones. Generalised linear models assessed the association of WBGT zone on heat-related medical incidences and matchplay variables. On-court calls for doctor (47% increase per zone, p=0.001), heat-related events (41%, p=0.019), cooling devices (53%, p<0.001), and post-match heat-related consults (87%, p=0.014) increased with each rise in estimated WBGT zone. In WBGT's >32°C and >28°C, significant increases in heat-related calls (p=0.019) and calls for cooling devices (p<0.001), respectively, were evident. The number of winners (-2.5±0.006% per zone, p<0.001) and net approaches (-7.1±0.008%, p<0.001) reduced as the estimated WBGT zone increased, while return points won increased (1.75±0.46, p<0.001). When matches were adjusted for player quality of the opponent (Elo rating), the number of aces (5±0.02%, p=0.003) increased with estimated WBGT zone, whilst net approaches decreased (7.6±0.013%, p<0.001). Increased estimated WBGT increased total match doctor and trainer consults for heat related-incidents, post-match heat-related consults (>32°C) and cooling device callouts (>28°C). However, few matchplay characteristics were noticeably affected, with only reduced net approaches and increased aces evident in higher estimated WBGT environments. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. Influence of snow cover changes on surface radiation and heat balance based on the WRF model

    NASA Astrophysics Data System (ADS)

    Yu, Lingxue; Liu, Tingxiang; Bu, Kun; Yang, Jiuchun; Chang, Liping; Zhang, Shuwen

    2017-10-01

    The snow cover extent in mid-high latitude areas of the Northern Hemisphere has significantly declined corresponding to the global warming, especially since the 1970s. Snow-climate feedbacks play a critical role in regulating the global radiation balance and influencing surface heat flux exchange. However, the degree to which snow cover changes affect the radiation budget and energy balance on a regional scale and the difference between snow-climate and land use/cover change (LUCC)-climate feedbacks have been rarely studied. In this paper, we selected Heilongjiang Basin, where the snow cover has changed obviously, as our study area and used the WRF model to simulate the influences of snow cover changes on the surface radiation budget and heat balance. In the scenario simulation, the localized surface parameter data improved the accuracy by 10 % compared with the control group. The spatial and temporal analysis of the surface variables showed that the net surface radiation, sensible heat flux, Bowen ratio, temperature and percentage of snow cover were negatively correlated and that the ground heat flux and latent heat flux were positively correlated with the percentage of snow cover. The spatial analysis also showed that a significant relationship existed between the surface variables and land cover types, which was not obviously as that for snow cover changes. Finally, six typical study areas were selected to quantitatively analyse the influence of land cover types beneath the snow cover on heat absorption and transfer, which showed that when the land was snow covered, the conversion of forest to farmland can dramatically influence the net radiation and other surface variables, whereas the snow-free land showed significantly reduced influence. Furthermore, compared with typical land cover changes, e.g., the conversion of forest into farmland, the influence of snow cover changes on net radiation and sensible heat flux were 60 % higher than that of land cover changes, indicating the importance of snow cover changes in the surface-atmospheric feedback system.

  2. [Simulation experiment of survival and reproduction of artificially imported Oncomelania snails in Qingpu District, Shanghai].

    PubMed

    Tian, Jian-Guo; Li, Gui-Fu; Li, Jun; Zhang, Xiao-Ping; Jin, Yan-Jun; Cai, Li; Peng, Li-Xia; Xu, Hai-Yan; Xu, Rui-Fang

    2013-06-01

    To understand the survival of imported Oncomelania snails in new environments with different densities in waterway net region, Qingpu District, Shanghai. The snails collected from Guichi, Anhui Province were put into the ponds of 4 square meters and each had 25, 50, 100, 200, 400 and 800 pairs of snails, respectively. During the next 2 years, the temperature, humidity, the activities of snails and their second birth snails were investigated each day. All the data were analyzed statistically. The highest number of snails appeared from May to June on the surface of soils in different densities. The average numbers of snails were 2.0%-12.7% of whole put in snails, and the numbers of offspring were less than 2% of the whole put in snails. The survival and reproduction of artificially imported Oncomelania snails from Guichi, Anhui Province is not good in Qingpu District, Shanghai.

  3. Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, M.A.; Durfee, D.J.; Hughes, P.J.

    1999-06-19

    The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 cents/ft{sup 2}-yr, WCC/GSB schools at 3.73 cents/ft{sup 2}-yr, and WCC/GHWB schools at 6.07 cents/ft{sup 2}-yr. Because of tax-exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2}=O.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less

  4. Comparing maintenance costs of geothermal heat pump systems with other HVAC systems in Lincoln public schools: Repair, service, and corrective actions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, M.A.; Durfee, D.J.; Hughes, P.J.

    1999-07-01

    The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four new elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service, and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACC/GHWB), water-cooled chiller with gas-fired hot water boiler (WCC/GHWB), or water-cooled chiller with gas-fired steam boiler (WCC/GSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13{cents}/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.884{cents}/ft{sup 2}-yr, WCC/GSB schools at 3.73{cents}/ft{sup 2}-yr, and WCC/GHWB schools at 6.07{cents}/ft{sup 2}-yr. Because of tax exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2} = 0.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less

  5. Wealth, mother's education and physical access as determinants of retail sector net use in rural Kenya

    PubMed Central

    2006-01-01

    Background Insecticide-treated bed nets (ITN) provide real hope for the reduction of the malaria burden across Africa. Understanding factors that determine access to ITN is crucial to debates surrounding the optimal delivery systems. The influence of homestead wealth on use of nets purchased from the retail sector is well documented, however, the competing influence of mother's education and physical access to net providers is less well understood. Methods Between December 2004 and January 2005, a random sample of 72 rural communities was selected across four Kenyan districts. Demographic, assets, education and net use data were collected at homestead, mother and child (aged < 5 years) levels. An assets-based wealth index was developed using principal components analysis, travel time to net sources was modelled using geographic information systems, and factors influencing the use of retail sector nets explored using a multivariable logistic regression model. Results Homestead heads and guardians of 3,755 children < 5 years of age were interviewed. Approximately 15% (562) of children slept under a net the night before the interview; 58% (327) of the nets used were purchased from the retail sector. Homestead wealth (adjusted OR = 10.17, 95% CI = 5.45–18.98), travel time to nearest market centres (adjusted OR = 0.51, 95% CI = 0.37–0.72) and mother's education (adjusted OR = 2.92, 95% CI = 1.93–4.41) were significantly associated with use of retail sector nets by children aged less than 5 years. Conclusion Approaches to promoting access to nets through the retail sector disadvantage poor and remote communities where mothers are less well educated. PMID:16436216

  6. Efficacy of permethrin treated long-lasting insecticidal nets on malaria transmission and observations on the perceived side effects, collateral benefits and human safety in a hyperendemic tribal area of Orissa, India.

    PubMed

    Sharma, Surya K; Tyagi, Prajesh K; Upadhyay, Ashok K; Haque, Mohammed A; Mohanty, Suman S; Raghavendra, Kamaraju; Dash, Aditya P

    2009-11-01

    Studies were conducted on the efficacy of Olyset nets-a long-lasting insecticidal net (LLIN) factory treated with 2% (w/w) permethrin on malaria transmission in an area under the influence of pyrethroid susceptible vector species Anopheles culicifacies and A. fluviatilis in Sundargarh District, Orissa, India. The study area comprised 22 villages that were randomized into three clusters and designated as Olyset net, untreated net, and no net area. Malaria incidence in the study population was measured through longitudinal active surveillance at fortnightly intervals. There was a reduction of 65-70% in malaria incidence in Olyset net area as compared to the control areas. The attack rate of Plasmodium falciparum or number of episodes per person per year in different age groups also showed significant reduction in Olyset net area as compared to untreated net and no net areas. Cross-sectional point prevalence surveys showed 45.7% reduction of malaria prevalence in Olyset net users, whereas there was an increase of 33.3% and 51% in untreated net and no net villages respectively. The compliance rate of Olyset net usage in the study population was 80-98% during different months, whereas it was between 70% and 90% for untreated nets. There were minimal complains of skin irritation (4%), itching (8%) and eye irritation (1.2%). However, these effects were only transitory in nature lasting for few hours of the first usage. Olyset nets also provided collateral benefits in terms of relief not only from mosquitoes and malaria but also from other household pests such as head lice, bed bugs, cockroaches, ants and houseflies. The Olyset nets were found to be safe to humans as no adverse event was recorded in the net users that can be attributed to the use of net. The study showed that Olyset nets are effective personal protection tool that can be used in a community based intervention programme.

  7. Annual Performance of a Two-Speed, Dedicated Dehumidification Heat Pump in the NIST Net-Zero Energy Residential Test Facility

    PubMed Central

    Payne, W. Vance

    2017-01-01

    A 2715 ft2 (252 m2), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft-2, 51.7 kWh m-2), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft-2, 24.7 kWh m-2) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W-1h-1 (2.95 W W-1), relative to the rated SEER of the heat pump of 15.8 Btu W-1h-1 (4.63 W W-1). Annual heating efficiency was 7.10 Btu W-1h-1 (2.09 W W-1), compared with the unit's rated HSPF of 9.05 Btu W-1h-1 (2.65 W W-1). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively. PMID:28729740

  8. Annual Performance of a Two-Speed, Dedicated Dehumidification Heat Pump in the NIST Net-Zero Energy Residential Test Facility.

    PubMed

    Payne, W Vance

    2016-01-01

    A 2715 ft 2 (252 m 2 ), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft -2 , 51.7 kWh m -2 ), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft -2, 24.7 kWh m -2 ) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W -1 h -1 (2.95 W W -1 ), relative to the rated SEER of the heat pump of 15.8 Btu W -1 h -1 (4.63 W W -1 ). Annual heating efficiency was 7.10 Btu W -1 h -1 (2.09 W W -1 ), compared with the unit's rated HSPF of 9.05 Btu W -1 h -1 (2.65 W W -1 ). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively.

  9. Systems with a constant heat flux with applications to radiative heat transport across nanoscale gaps and layers

    NASA Astrophysics Data System (ADS)

    Budaev, Bair V.; Bogy, David B.

    2018-06-01

    We extend the statistical analysis of equilibrium systems to systems with a constant heat flux. This extension leads to natural generalizations of Maxwell-Boltzmann's and Planck's equilibrium energy distributions to energy distributions of systems with a net heat flux. This development provides a long needed foundation for addressing problems of nanoscale heat transport by a systematic method based on a few fundamental principles. As an example, we consider the computation of the radiative heat flux between narrowly spaced half-spaces maintained at different temperatures.

  10. Using compression calorimetry to characterize powder compaction behavior of pharmaceutical materials.

    PubMed

    Buckner, Ira S; Friedman, Ross A; Wurster, Dale Eric

    2010-02-01

    The process by which pharmaceutical powders are compressed into cohesive compacts or tablets has been studied using a compression calorimeter. Relating the various thermodynamic results to relevant physical processes has been emphasized. Work, heat, and internal energy change values have been determined with the compression calorimeter for common pharmaceutical materials. A framework of equations has been proposed relating the physical processes of friction, reversible deformation, irreversible deformation, and inter-particle bonding to the compression calorimetry values. The results indicate that irreversible deformation dominated many of the thermodynamic values, especially the net internal energy change following the compression-decompression cycle. The relationships between the net work and the net heat from the complete cycle were very clear indicators of predominating deformation mechanisms. Likewise, the ratio of energy stored as internal energy to the initial work input distinguished the materials according to their brittle or plastic deformation tendencies. (c) 2009 Wiley-Liss, Inc. and the American Pharmacists Association.

  11. Design Calculation Procedure for Passive Solar Houses at Navy Installations in Regions with Warm, Humid Climate. Volume III.

    DTIC Science & Technology

    1981-10-01

    and Storage Locations . ... 7 2.3 Heat Transfer Mechanisms of Thermal Storage Walls ...... ... 11 2.4 Heating of Living Space with Solar Greenhouse ...12 2.5 Schematic of North-Side Greenhouse Retrofit .... ......... 12 2.6 The Roof Pond in Warm Climate ................... ... 14 2.7...Building Thermal Load Profile ... ........ 48 5 Calculation of Solar Heating Contribution ............. 52 5A Adjusted Net Solar Greenhouse Heat Gain

  12. Characteristics of large thermal energy storage systems in Poland

    NASA Astrophysics Data System (ADS)

    Zwierzchowski, Ryszard

    2017-11-01

    In District Heating Systems (DHS) there are significant fluctuations in demand for heat by consumers during both the heating and the summer seasons. These variations are considered primarily in the 24-hour time horizon. These problems are aggravated further if the DHS is supplied by a CHP plant, because fluctuations in heat demand adversely affect to a significant degree the stable production of electricity at high overall efficiency. Therefore, introducing Thermal Energy Storage (TES) would be highly recommended on these grounds alone. The characteristics of Large (i.e. over 10 000 m3) TES in operation in Poland are presented. Information is given regarding new projects (currently in design or construction) that apply TES technology in DHS in Poland. The paper looks at the methodology used in Poland to select the TES system for a particular DHS, i.e., procedure for calculating capacity of the TES tank and the system to prevent water stored in the tank from absorbing oxygen from atmospheric air. Implementation of TES in DHS is treated as a recommended technology in the Polish District Heating sector. This technology offers great opportunities to improve the operating conditions of DHS, cutting energy production costs and emissions of pollutants to the atmosphere.

  13. Analysis of Low-Temperature Utilization of Geothermal Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Brian

    Full realization of the potential of what might be considered “low-grade” geothermal resources will require that we examine many more uses for the heat than traditional electricity generation. To demonstrate that geothermal energy truly has the potential to be a national energy source we will be designing, assessing, and evaluating innovative uses for geothermal-produced water such as hybrid biomass-geothermal cogeneration of electricity and district heating and efficiency improvements to the use of cellulosic biomass in addition to utilization of geothermal in district heating for community redevelopment projects. The objectives of this project were: 1) to perform a techno-economic analysis ofmore » the integration and utilization potential of low-temperature geothermal sources. Innovative uses of low-enthalpy geothermal water were designed and examined for their ability to offset fossil fuels and decrease CO2 emissions. 2) To perform process optimizations and economic analyses of processes that can utilize low-temperature geothermal fluids. These processes included electricity generation using biomass and district heating systems. 3) To scale up and generalize the results of three case study locations to develop a regionalized model of the utilization of low-temperature geothermal resources. A national-level, GIS-based, low-temperature geothermal resource supply model was developed and used to develop a series of national supply curves. We performed an in-depth analysis of the low-temperature geothermal resources that dominate the eastern half of the United States. The final products of this study include 17 publications, an updated version of the cost estimation software GEOPHIRES, and direct-use supply curves for low-temperature utilization of geothermal resources. The supply curves for direct use geothermal include utilization from known hydrothermal, undiscovered hydrothermal, and near-hydrothermal EGS resources and presented these results at the Stanford Geothermal Workshop. We also have incorporated our wellbore model into TOUGH2-EGS and began coding TOUGH2-EGS with the wellbore model into GEOPHIRES as a reservoir thermal drawdown option. Additionally, case studies for the WVU and Cornell campuses were performed to assess the potential for district heating and cooling at these two eastern U.S. sites.« less

  14. Determination of the predictive factors of long-lasting insecticide-treated net ownership and utilisation in the Bamenda Health District of Cameroon.

    PubMed

    Fokam, Eric B; Kindzeka, Germaine F; Ngimuh, Leonard; Dzi, Kevin T J; Wanji, Samuel

    2017-03-16

    Malaria is a serious health concern in Africa. In Cameroon, an endemic country where malaria remains a major public health problem, several control measures have been put in place among which the use of insecticide-treated bednets (LLINs/ITNs) is considered one of the core vector control strategies. However, the greatest challenges include ownership and utilisation by individuals and households. Factors such as age, marital status, gender, education and occupation of the household head, household size, knowledge of bednets, socioeconomic status, and environmental factors have been suggested to have an impact on bednet ownership and utilisation in different settings. The present study sought to determine bednet ownership and utilisation rates and to assess the impact of predictive factors on bednet ownership and use in the Bamenda Health District (BHD) of Cameroon. A cross-sectional study involving 384 households was conducted in six health areas in the BHD. A structured and semi-structured questionnaire was used to collect data on demographic and household characteristics as well as information on their bednet ownership and utilisation. Descriptive statistics, bivariate and multivariate logistic regression analysis were performed. Frequency of bednet ownership was relatively high (63.5%) with LLINs being most abundant (91.9%); the majority of households (87.7%) obtained their bednets during the 2011 free distribution campaign. Utilisation was relatively high (69.3%), with negligence (29.3%) and heat discomfort (26.7%) accounting most for non-usage of bednets. Children less than 5 years (63%) and pregnant women (60%) most often used these nets. Households headed by a married couple, those with older household heads, household with smaller size (5-12 persons), and knowledge of bednets (good knowledge) had positive impacts on bednet ownership (p < 0.05). The gender of the household head (males), their educational level, environmental conditions (presence of suitable mosquito breeding sites), bednet number in households (greater number of bednets) and the prioritised groups (children < 5 and pregnant women) had positive impacts on bednet utilisation in households (p < 0.05). There was a negative association between bednet ownership and utilisation by households as bednet ownership was high and utilisation of these nets was low. Marital status and age of household head, household size, and knowledge of bednets had impacts on bednet ownership while gender and educational level of the household head, environmental suitability, the number of bednets and the two prioritised groups had an impact on bednet usage. These factors may be relevant for policy makers and in decision making for the intensification of campaign strategies to ensure more effective subsequent distribution campaigns in the BHD and beyond.

  15. Recent Advances in Near-Net-Shape Fabrication of Al-Li Alloy 2195 for Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Wagner, John; Domack, Marcia; Hoffman, Eric

    2007-01-01

    Recent applications in launch vehicles use 2195 processed to Super Lightweight Tank specifications. Potential benefits exist by tailoring heat treatment and other processing parameters to the application. Assess the potential benefits and advocate application of Al-Li near-net-shape technologies for other launch vehicle structural components. Work with manufacturing and material producers to optimize Al-Li ingot shape and size for enhanced near-net-shape processing. Examine time dependent properties of 2195 critical for reusable applications.

  16. Energy efficiency in waste-to-energy and its relevance with regard to climate control.

    PubMed

    Ragossnig, Arne M; Wartha, Christian; Kirchner, Andreas

    2008-02-01

    This article focuses on systematically highlighting the ways to optimize waste-to-energy plants in terms of their energy efficiency as an indicator of the positive effect with regard to climate control. Potentials for increasing energy efficiency are identified and grouped into categories. The measures mentioned are illustrated by real-world examples. As an example, district cooling as a means for increasing energy efficiency in the district heating network of Vienna is described. Furthermore a scenario analysis shows the relevance of energy efficiency in waste management scenarios based on thermal treatment of waste with regard to climate control. The description is based on a model that comprises all relevant processes from the collection and transportation up to the thermal treatment of waste. The model has been applied for household-like commercial waste. The alternatives compared are a combined heat and power incinerator, which is being introduced in many places as an industrial utility boiler or in metropolitan areas where there is a demand for district heating and a classical municipal solid waste incinerator producing solely electrical power. For comparative purposes a direct landfilling scenario has been included in the scenario analysis. It is shown that the energy efficiency of thermal treatment facilities is crucial to the quantity of greenhouse gases emitted.

  17. [Community participation in health promotion: an experience from hygiene and sanitation committees in the district of Touba (Senegal)].

    PubMed

    Diedhiou, Abdoulaye; Ndiaye, Papa; Sourang, Amadou Moustapha; Ba, Amadou Djibril; Diallo, Issakha

    2006-01-01

    This qualitative exploratory study carried out in November 2000 describes and analyzes health promotion by community participation in the health district of Touba, in Senegal. The committees were primarily made up of women with an implication of local religious authorities which represented the moral responsible. The promotional activities regularly carried out were: health education, distribution of insecticide treated nets, police in waste management and hygiene, and cleaning. Theses activities were supported through the development of income generating activities. The success of the communities is based on the favorable socio-religious environment, strengthened by the particular commitment of the women. The diversity of activities undertaken by the committees is a proof that the identification of people's needs was not limited to health care questions. The community leadership was stimulated by the district, to enhance the dynamics of participation. The financial autonomy of the majority of communities is a guarantee of their sustainability within the district health system. Extremely encouraging results obtained, two essential recommendations were made to strengthen the experience of sanitation committees in health promotion.

  18. Solar energy system performance evaluation: Seasonal report for Fern Lansing, Lansing, Michigan

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A solar space heating and hot water system's operational performance from April 1979 through March 1980 is evaluated. Solar energy satisfied 15 percent of the total measured load (hot water plus space heating). Net savings were approximately 21 million BTUs.

  19. Reduced-Stress Mounting for Thermocouples

    NASA Technical Reports Server (NTRS)

    Wood, C.

    1986-01-01

    Mounting accommodates widely different coefficients of thermal expansion. In new method, legs of thermocouple placed in separate n- and p-type arrays. Two arrays contact common heat pipe as source but have separate heatpipe sinks. Net expansion (or contraction) taken up by spring mounting on heat-pipe sinks.

  20. Assessing the impact of scaling-up bednet coverage through agricultural loan programmes: evidence from a cluster randomised controlled trial in Katete, Zambia.

    PubMed

    Fink, Günther; Masiye, Felix

    2012-11-01

    To investigate the effectiveness of scaling-up existing bednet distribution campaigns, a randomised controlled trial with 516 farming households in Katete District, a rural area with highly endemic malaria in Zambia's Eastern Province, was evaluated. In the trial, selected farmers were assigned to bednet programmes that allowed them to obtain additional bednets for free or at subsidised prices through agricultural loan programmes. On average, 2.4 nets were distributed in the free distribution group and 0.9 in the net loan group. The marginal health impact of additional nets appears large, reducing the odds of self-reported all-cause morbidity by 40-42% and the odds of self-reported confirmed malaria by 53-60%. Copyright © 2012 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  1. Exertional Heat Illness among Secondary School Athletes: Statewide Policy Implications

    ERIC Educational Resources Information Center

    Rodgers, Jill; Slota, Peggy; Zamboni, Beth

    2018-01-01

    Exertional heat illness (EHI) is a leading cause of preventable death among student athletes. While causes and preventative measures for EHI are known, school districts may not be implementing evidence-based practices. This descriptive, exploratory study explored school policies, resources, and practices of coaches in a mid-Atlantic state in the…

  2. The Canopy Conductance of a Humid Grassland

    NASA Astrophysics Data System (ADS)

    Lu, C. T.; Hsieh, C. I.

    2015-12-01

    Penman-Monteith equation is widely used for estimating latent heat flux. The key parameter for implementing this equation is the canopy conductance (gc). Recent research (Blaken and Black, 2004) showed that gc could be well parameterized by a linear function of An/ (D0* X0c), where An represents net assimilation, D0 is leaf level saturation deficit, and X0c is CO2 mole fraction. In this study, we tried to use the same idea for estimating gcfor a humid grassland. The study site was located in County Cork, southwest Ireland (51o59''N 8o46''W), and perennial ryegrass (Lolium perenne L.) was the dominant grass species in this area. An eddy covariance system was used to measure the latent heat flux above this humid grassland. The measured gc was calculated by rearranging Penman-Monteith equation combined with the measured latent heat flux. Our data showed that the gc decreased as the vapor pressure deficit and temperature increased. And it increased as the net radiation increased. Therefore, we found out that the best parameterization of gc was a linear function of the product of the vapor deficit, temperature, and net radiation. Also, we used the gc which was estimated by this linear function to predict the latent heat flux by Penman-Monteith equation and compared the predictions with those where the gc was chosen to be a fixed value. Our analysis showed that this simple linear function for gc can improve the latent heat flux predictions (R square increased from 0.48 to 0.66).

  3. The Influence of a Sandy Substrate, Seagrass, or Highly Turbid Water on Albedo and Surface Heat Flux

    NASA Astrophysics Data System (ADS)

    Fogarty, M. C.; Fewings, M. R.; Paget, A. C.; Dierssen, H. M.

    2018-01-01

    Sea-surface albedo is a combination of surface-reflected and water-leaving irradiance, but water-leaving irradiance typically contributes less than 15% of the total albedo in open-ocean conditions. In coastal systems, however, the bottom substrate or suspended particulate matter can increase the amount of backscattered light, thereby increasing albedo and decreasing net shortwave surface heat flux. Here a sensitivity analysis using observations and models predicts the effect of light scattering on albedo and the net shortwave heat flux for three test cases: a bright sand bottom, a seagrass canopy, and turbid water. After scaling to the full solar shortwave spectrum, daytime average albedo for the test cases is up to 0.20 and exceeds the value of 0.05 predicted using a commonly applied parameterization. Daytime net shortwave heat flux into the water is significantly reduced, particularly for waters with bright sediments, dense horizontal seagrass canopies < 0.25 m from the sea surface, or highly turbid waters with suspended particulate matter concentration ≥ 50 g m-3. Observations of a more vertical seagrass canopy within 0.2 and 1 m of the surface indicate the increase in albedo compared to the common parameterization is negligible. Therefore, we suggest that the commonly applied albedo lookup table can be used in coastal heat flux estimates in water as shallow as 1 m unless the bottom substrate is highly reflective or the water is highly turbid. Our model results provide guidance to researchers who need to determine albedo in highly reflective or highly turbid conditions but have no direct observations.

  4. Solar Flux Deposition And Heating Rates In Jupiter's Atmosphere

    NASA Astrophysics Data System (ADS)

    Perez-Hoyos, Santiago; Sánchez-Lavega, A.

    2009-09-01

    We discuss here the solar downward net flux in the 0.25 - 2.5 µm range in the atmosphere of Jupiter and the associated heating rates under a number of vertical cloud structure scenarios focusing in the effect of clouds and hazes. Our numerical model is based in the doubling-adding technique to solve the radiative transfer equation and it includes gas absorption by CH4, NH3 and H2, in addition to Rayleigh scattering by a mixture of H2 plus He. Four paradigmatic Jovian regions have been considered (hot-spots, belts, zones and Polar Regions). The hot-spots are the most transparent regions with downward net fluxes of 2.5±0.5 Wm-2 at the 6 bar level. The maximum solar heating is 0.04±0.01 K/day and occurs above 1 bar. Belts and zones characterization result in a maximum net downward flux of 0.5 Wm-2 at 2 bar and 0.015 Wm-2 at 6 bar. Heating is concentrated in the stratospheric and tropospheric hazes. Finally, Polar Regions are also explored and the results point to a considerable stratospheric heating of 0.04±0.02 K/day. In all, these calculations suggest that the role of the direct solar forcing in the Jovian atmospheric dynamics is limited to the upper 1 - 2 bar of the atmosphere except in the hot-spot areas. Acknowledgments: This work has been funded by Spanish MEC AYA2006-07735 with FEDER support and Grupos Gobierno Vasco IT-464-07.

  5. Shannon entropic temperature and its lower and upper bounds for non-Markovian stochastic dynamics

    NASA Astrophysics Data System (ADS)

    Ray, Somrita; Bag, Bidhan Chandra

    2014-09-01

    In this article we have studied Shannon entropic nonequilibrium temperature (NET) extensively for a system which is coupled to a thermal bath that may be Markovian or non-Markovian in nature. Using the phase-space distribution function, i.e., the solution of the generalized Fokker Planck equation, we have calculated the entropy production, NET, and their bounds. Other thermodynamic properties like internal energy of the system, heat, and work, etc. are also measured to study their relations with NET. The present study reveals that the heat flux is proportional to the difference between the temperature of the thermal bath and the nonequilibrium temperature of the system. It also reveals that heat capacity at nonequilibrium state is independent of both NET and time. Furthermore, we have demonstrated the time variations of the above-mentioned and related quantities to differentiate between the equilibration processes for the coupling of the system with the Markovian and the non-Markovian thermal baths, respectively. It implies that in contrast to the Markovian case, a certain time is required to develop maximum interaction between the system and the non-Markovian thermal bath (NMTB). It also implies that longer relaxation time is needed for a NMTB compared to a Markovian one. Quasidynamical behavior of the NMTB introduces an oscillation in the variation of properties with time. Finally, we have demonstrated how the nonequilibrium state is affected by the memory time of the thermal bath.

  6. Extending the Performance of Net Shape Molded Fiber Reinforced Polymer Composite Valves for Use in Internal Combustion Engines

    DTIC Science & Technology

    2007-06-01

    management has been of increasingly significant importance. The combination of conventional materials and heat pipes have been applied in designs to take...chemical heat exchangers 87. In another spacecraft application, a carbon fiber face sheets with aluminum heat pipes embedded in an aluminum honeycomb...core were developed to replace an older all aluminum design. The heat pipes use ammonia as the working fluid. The new design improved thermal performance

  7. Field testing of two prototype air-source integrated heat pumps for net zero energy home (nZEH) application

    DOE PAGES

    Baxter, Van D.; Munk, Jeffrey D.

    2017-11-08

    By integrating multiple functions into a single system it offers potential efficiency and cost reduction benefits. Oak Ridge National Laboratory (ORNL) and its partners have designed, developed, and tested two air-source heat pump designs that not only provide space heating and cooling, but also water heating, dehumidification, and ventilation functions. Some details on the design, simulated performance, prototype field test, measured performance, and lessons learned are provided.

  8. Field testing of two prototype air-source integrated heat pumps for net zero energy home (nZEH) application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D.; Munk, Jeffrey D.

    By integrating multiple functions into a single system it offers potential efficiency and cost reduction benefits. Oak Ridge National Laboratory (ORNL) and its partners have designed, developed, and tested two air-source heat pump designs that not only provide space heating and cooling, but also water heating, dehumidification, and ventilation functions. Some details on the design, simulated performance, prototype field test, measured performance, and lessons learned are provided.

  9. [Characteristics of water and heat fluxes and its footprint climatology on farmland in low hilly region of red soil].

    PubMed

    Li, Yang; Jing, Yuan Shu; Qin, Ben Ben

    2017-01-01

    The analysis of the characteristics and footprint climatology of farmland water and heat fluxes has great significance to strengthen regional climate resource management and improve the hydrothermal resource utilization in the region of red soil. Based on quality controlled data from large aperture scintillometer and automatic meteorological station in hilly region of red soil, this paper analyzed in detail the characteristics of farmland water and heat fluxes at different temporal scales and the corresponding source area distribution of flux measurement in the non-rainy season and crop growth period in hilly region of red soil. The results showed that the diurnal variation of water and heat fluxes showed a unimodal trend, but compared with the sunny day, the diurnal variation curves fluctuated more complicatedly on cloudy day. In the whole, either ten-day periods or month scale, the water and heat fluxes were greater in August than in September, while the net radiation flux was more distributed to latent heat exchange. The proportion of net radiation to latent heat flux decreased in September compared to August, but the sensible heat flux was vice versa. With combined effects of weather conditions (particularly wind), stability, and surface condition, the source areas of flux measurement at different temporal scales showed different distribution characteristics. Combined with the underlying surface crops, the source areas at different temporal scales also had different contribution sources.

  10. Evaluation of major heat waves' mechanisms in EURO-CORDEX RCMs over Central Europe

    NASA Astrophysics Data System (ADS)

    Lhotka, Ondřej; Kyselý, Jan; Plavcová, Eva

    2018-06-01

    The main aim of the study is to evaluate the capability of EURO-CORDEX regional climate models (RCMs) to simulate major heat waves in Central Europe and their associated meteorological factors. Three reference major heat waves (1994, 2006, and 2015) were identified in the E-OBS gridded data set, based on their temperature characteristics, length and spatial extent. Atmospheric circulation, precipitation, net shortwave radiation, and evaporative fraction anomalies during these events were assessed using the ERA-Interim reanalysis. The analogous major heat waves and their links to the aforementioned factors were analysed in an ensemble of EURO-CORDEX RCMs driven by various global climate models in the 1970-2016 period. All three reference major heat waves were associated with favourable circulation conditions, precipitation deficit, reduced evaporative fraction and increased net shortwave radiation. This joint contribution of large-scale circulation and land-atmosphere interactions is simulated with difficulties in majority of the RCMs, which affects the magnitude of modelled major heat waves. In some cases, the seemingly good reproduction of major heat waves' magnitude is erroneously achieved through extremely favourable circulation conditions compensated by a substantial surplus of soil moisture or vice versa. These findings point to different driving mechanisms of major heat waves in some RCMs compared to observations, which should be taken into account when analysing and interpreting future projections of these events.

  11. Estimating changes in heat energy stored within a column of wetland surface water and factors controlling their importance in the surface energy budget

    USGS Publications Warehouse

    Shoemaker, W. Barclay; Sumner, David M.; Castillo, Adrian

    2005-01-01

    Changes in heat energy stored within a column of wetland surface water can be a considerable component of the surface energy budget, an attribute that is demonstrated by comparing changes in stored heat energy to net radiation at seven sites in the wetland areas of southern Florida, including the Everglades. The magnitude of changes in stored heat energy approached the magnitude of net radiation more often during the winter dry season than during the summer wet season. Furthermore, the magnitude of changes in stored heat energy in wetland surface water generally decreased as surface energy budgets were upscaled temporally. A new method was developed to estimate changes in stored heat energy that overcomes an important data limitation, namely, the limited spatial and temporal availability of water temperature measurements. The new method is instead based on readily available air temperature measurements and relies on the convolution of air temperature changes with a regression‐defined transfer function to estimate changes in water temperature. The convolution‐computed water temperature changes are used with water depths and heat capacity to estimate changes in stored heat energy within the Everglades wetland areas. These results likely can be adapted to other humid subtropical wetlands characterized by open water, saw grass, and rush vegetation type communities.

  12. 77 FR 28872 - Willwood Irrigation District; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-16

    ... containing one turbine rated for 780 kilowatts at 43.08 feet of net head; (4) a 75-foot-long, 8-foot.../efiling.asp . Commenters can submit brief comments up to 6,000 characters, without prior registration, using the eComment system at http://www.ferc.gov/docs-filing/ecomment.asp . You must include your name...

  13. 78 FR 48666 - Browns Valley Irrigation District; Notice of Declaration of Intention and Soliciting Comments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-09

    ...-comments.asp . Please include the docket number (DI13-6-000) on any comments, protests, and/or motions... feet per second at 266 feet of net head; and appurtenant facilities. The project will be connected to... at http://www.ferc.gov/docs-filing/esubscription.asp to be notified via email of new filings and...

  14. 77 FR 27768 - Greybull Valley Irrigation District; Notice of Preliminary Permit Application Accepted for Filing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... totaling 5 megawatts or less in capacity at 170 feet of net head; (3) a tailrace discharging flows to....gov/docs-filing/efiling.asp . Commenters can submit brief comments up to 6,000 characters, without prior registration, using the eComment system at http://www.ferc.gov/docs-filing/ecomment.asp . You must...

  15. 77 FR 27769 - Greybull Valley Irrigation District; Notice of Preliminary Permit Application Accepted for Filing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... unit rated at 5 megawatts or less at 150 feet of net head; (3) a tailrace channel discharging from the... instructions on the Commission's Web site http://www.ferc.gov/docs-filing/efiling.asp . Commenters can submit...://www.ferc.gov/docs-filing/ecomment.asp . You must include your name and contact information at the end...

  16. Microcomputers in Florida Public Schools. Fall 1991. MIS Statistical Brief, Series 92-06B.

    ERIC Educational Resources Information Center

    Parks, Brenda; Bennett, Karen

    This statistical brief on microcomputers in Florida public schools includes data on the following: (1) the number of instructional microcomputers from 1987-88 to 1991-92; (2) the number of instructional microcomputers for each school district from 1987-88 to 1991-92, including net change from 1990-91 to 1991-92; (3) percentages of instructional…

  17. Assessing the Effectiveness of E-Learning Integration in College Physics in the Alamo Community Colleges District

    ERIC Educational Resources Information Center

    Zhou, Qiaoying

    2012-01-01

    Academic achievement and student participation in physics are lower than desired. Research has shown that there is a shortage of college students entering science and technology fields such as physics. E-learning may provide the technology-oriented Net Generation learner an option for taking courses such as physics in a course modality with which…

  18. An Economic Analysis of Pigeonpea Seed Production Technology and Its Adoption Behavior: Indian Context.

    PubMed

    Pal, Govind; Channanamchery, Radhika; Singh, R K; Kethineni, Udaya Bhaskar; Ram, H; Prasad, S Rajendra

    2016-01-01

    The present study was based on primary data collected from 100 farmers in Gulbarga district of Karnataka, India, during the agricultural year 2013-2014. Study shows that average land holding size of pigeonpea seed farmers was higher in comparison to grain farmers and district average. The study illustrates a ratio of 32 : 68 towards fixed and variable costs in pigeonpea certified seed production with a total cost of ₹ 39436 and the gross and net returns were ₹ 73300 and ₹ 33864 per hectare, respectively. The total cost of cultivation, gross return, and net return in pigeonpea seed production were higher by around 23, 32, and 44 percent than grain production, respectively. Hence, production of certified seed has resulted in a win-win situation for the farmers with higher yield and increased returns. The decision of the farmer on adoption of seed production technology was positively influenced by his education, age, land holding, irrigated land, number of crops grown, and extension contacts while family size was influencing negatively. Higher yield and profitability associated with seed production can be effectively popularized among farmers, resulting in increased certified seed production.

  19. Ice Slurry Ingestion Leads to a Lower Net Heat Loss during Exercise in the Heat.

    PubMed

    Morris, Nathan B; Coombs, Geoff; Jay, Ollie

    2016-01-01

    To compare the reductions in evaporative heat loss from the skin (Esk) to internal heat loss (Hfluid) induced by ice slurry (ICE) ingestion relative to 37 °C fluid and the accompanying body temperature and local thermoeffector responses during exercise in warm, dry conditions (33.5 °C ± 1.4 °C; 23.7% ± 2.6% relative humidity [RH]). Nine men cycled at approximately 55% VO2peak for 75 min and ingested 3.2 mL · kg(-1) aliquots of 37 °C fluid or ICE after 15, 30, and 45 min of exercise. Metabolic heat production (M-W), rectal temperature (Tre), mean skin temperature (Tsk), whole-body sweat loss (WBSL), local sweat rate (LSR), and skin blood flow (SkBF) were measured throughout. Net heat loss (HLnet) and heat storage (S) were estimated using partitional calorimetry. Relative to the 37 °C trial, M-W was similar (P = 0.81) with ICE ingestion; however, the 200 ± 20 kJ greater Hfluid (P < 0.001) with ICE ingestion was overcompensated by a 381 ± 199-kJ lower Esk (P < 0.001). Net heat loss (HLnet) was consequently 131 ± 120 kJ lower (P = 0.01) and S was greater (P = 0.05) with ICE ingestion compared with 37 °C fluid ingestion. Concurrently, LSR and WBSL were lower by 0.16 ± 0.14 mg · min(-1) · cm(-2) (P < 0.01) and 191 ± 122 g (P < 0.001), respectively, and SkBF tended to be lower (P = 0.06) by 5.4%maxAU ± 13.4%maxAU in the ICE trial. Changes in Tre and Tsk were similar throughout exercise with ICE compared to 37 °C fluid ingestion. Relative to 37 °C, ICE ingestion caused disproportionately greater reductions in Esk relative to Hfluid, resulting in a lower HLnet and greater S. Mechanistically, LSR and possibly SkBF were suppressed independently of Tre or Tsk, reaffirming the concept of human abdominal thermoreception. From a heat balance perspective, recommendations for ICE ingestion during exercise in warm, dry conditions should be reconsidered.

  20. Seasonal thermal storage: Swedish practice, developments and cost projections

    NASA Astrophysics Data System (ADS)

    Margen, P.

    1981-06-01

    The types of heat store being developed in Sweden for seasonal storage of heat are discussed. This type of storage allows summer excess heat from industrial waste heat plants, garbage burning plants and future central solar heat stations to be stored for winter use on district heating networks. Whereas above ground steel or concrete tanks are usually too expensive insulated earth pits, uninsulated rock caverns and deep ground schemes using rock or clay promise to achieve sufficiently low costs to justify storage when supplied with free or cheap summer treat. For all these concepts demonstration plants were or are being built in Sweden.

  1. District heating and cooling systems for communities through power plant retrofit distribution network, Phase 2. Final report, March 1, 1980-January 31, 1984. Volume 5, Appendix A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1984-01-31

    This volume contains the backup data for the portion of the load and service assessment in Section 2, Volume II of this report. This includes: locations of industrial and commercial establishments, locations of high rise buildings, data from the Newark (Essex County) Directory of Business, data from the Hudson County Industrial Directory, data from the N. J. Department of Energy Inventory of Public Buildings, data on commercial and industrial establishments and new developments in the Hackensack Meadowlands, data on urban redevelopment and Operation Breakthrough, and list of streets in the potential district heating areas of Newark/Harrison and Jersey City/Hoboken.

  2. Comparisons of Source Characteristics between Recent Inland Crustal Earthquake Sequences inside and outside of Niigata-Kobe Tectonic Zone, Japan

    NASA Astrophysics Data System (ADS)

    Somei, K.; Asano, K.; Iwata, T.; Miyakoshi, K.

    2012-12-01

    After the 1995 Kobe earthquake, many M7-class inland earthquakes occurred in Japan. Some of those events (e.g., the 2004 Chuetsu earthquake) occurred in a tectonic zone which is characterized as a high strain rate zone by the GPS observation (Sagiya et al., 2000) or dense distribution of active faults. That belt-like zone along the coast in Japan Sea side of Tohoku and Chubu districts, and north of Kinki district, is called as the Niigata-Kobe tectonic zone (NKTZ, Sagiya et al, 2000). We investigate seismic scaling relationship for recent inland crustal earthquake sequences in Japan and compare source characteristics between events occurring inside and outside of NKTZ. We used S-wave coda part for estimating source spectra. Source spectral ratio is obtained by S-wave coda spectral ratio between the records of large and small events occurring close to each other from nation-wide strong motion network (K-NET and KiK-net) and broad-band seismic network (F-net) to remove propagation-path and site effects. We carefully examined the commonality of the decay of coda envelopes between event-pair records and modeled the observed spectral ratio by the source spectral ratio function with assuming omega-square source model for large and small events. We estimated the corner frequencies and seismic moment (ratio) from those modeled spectral ratio function. We determined Brune's stress drops of 356 events (Mw: 3.1-6.9) in ten earthquake sequences occurring in NKTZ and six sequences occurring outside of NKTZ. Most of source spectra obey omega-square source spectra. There is no obvious systematic difference between stress drops of events in NKTZ zone and others. We may conclude that the systematic tendency of seismic source scaling of the events occurred inside and outside of NKTZ does not exist and the average source scaling relationship can be effective for inland crustal earthquakes. Acknowledgements: Waveform data were provided from K-NET, KiK-net and F-net operated by National Research Institute for Earth Science and Disaster Prevention Japan. This study is supported by Multidisciplinary research project for Niigata-Kobe tectonic zone promoted by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan.

  3. Thermal energy storage to minimize cost and improve efficiency of a polygeneration district energy system in a real-time electricity market

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, Kody M.; Kim, Jong Suk; Cole, Wesley J.

    2016-10-01

    District energy systems can produce low-cost utilities for large energy networks, but can also be a resource for the electric grid by their ability to ramp production or to store thermal energy by responding to real-time market signals. In this work, dynamic optimization exploits the flexibility of thermal energy storage by determining optimal times to store and extract excess energy. This concept is applied to a polygeneration distributed energy system with combined heat and power, district heating, district cooling, and chilled water thermal energy storage. The system is a university campus responsible for meeting the energy needs of tens ofmore » thousands of people. The objective for the dynamic optimization problem is to minimize cost over a 24-h period while meeting multiple loads in real time. The paper presents a novel algorithm to solve this dynamic optimization problem with energy storage by decomposing the problem into multiple static mixed-integer nonlinear programming (MINLP) problems. Another innovative feature of this work is the study of a large, complex energy network which includes the interrelations of a wide variety of energy technologies. Results indicate that a cost savings of 16.5% is realized when the system can participate in the wholesale electricity market.« less

  4. Wind stress and heat fluxes over a Brazilian Coastal Upwelling

    NASA Astrophysics Data System (ADS)

    Dourado, Marcelo; Candella, Rogério

    2017-04-01

    Coastal upwelling zones have been intensively studied in the last decades especially due to their importance to the biological cycle. The coastal upwelling system of the Cabo Frio region (east coast of the Rio de Janeiro state, Brazil) keeps the surface water cold during most part of the year, what induces a stable atmospheric boundary layer associated to northeast winds. The main goal of this study is to investigate the wind stress and heat fluxes exchanges between the ocean and the atmosphere in that area. For this purpose, a set of hourly data meteorological and oceanographic data collected by a Wavescan metocean buoy anchored at 23o59S; 42oW, were used, as well as solar radiation and relative humidity from a terrestrial meteorological station from the Instituto Nacional de Meteorologia (InMet). COARE 3.0 algorithm was used to calculate the latent and sensible heat fluxes. In this discussion, positive values represent fluxes towards the ocean. The average net heat flux over our study period is 88 W m-2. The reduction of the net heat flux is due to the increase of the ocean latent heat loss, although a reduction in incoming shortwave radiation and an increase in ocean long wave cooling also contributes. The latent heat is 20 times larger than the sensible heat flux, but the mean value of the latent heat flux, 62 W m-2, is half the typical value found in open ocean. The temporal variability of both sensible and latent heat fluxes reflects their dependence on wind speed and air-sea temperature differences. When upwelling events, here periods when diurnal SST is lower than 18oC, are compared with undisturbed (without upwelling) events, it can be noted the sensible heat fluxes are positives and 10 times greater in magnitude. This is related to an increment, during these upwelling events, of the air-sea temperature difference and an increasing of the wind speed. The cold waters of the upwelling increase the air-sea temperature gradient and, also, the horizontal land-sea gradient. This could intensifies the sea breeze. At the same time, the latent heat flux to the atmosphere is reduced. As expected, cold waters from the upwelling imply in the reduction of the evaporation, and so the latent heat fluxes also reduce significantly. As upwelling events in this region are associated to the presence of the South Atlantic high pressure, NE winds, during these periods of cold water the net heat flux toward the ocean surface is intensified.

  5. Surface Meteorological Station - ANL 10m, (1) Sonics, (1) EBBR, Physics site-3 - Raw Data

    DOE Data Explorer

    Muradyan, Paytsar

    2017-10-23

    Sonic anemometers from Physics Site-3 and Site-9 provide wind components and virtual temperature. The energy balance Bowen ratio (EBBR) station at Physics site-3 provides measurements of the surface fluxes of latent and sensible heat, net radiation, and surface soil heat flux.

  6. Surface Meteorological Station - ANL 10m, (1) Sonic, Physics site-9 - Raw Data

    DOE Data Explorer

    Muradyan, Paytsar

    2017-10-23

    Sonic anemometers from Physics Site-3 and Site-9 provide wind components and virtual temperature. The energy balance Bowen ratio (EBBR) station at Physics site-3 provides measurements of the surface fluxes of latent and sensible heat, net radiation, and surface soil heat flux.

  7. Surface Meteorological Station - ANL 10m, (1) Sonics, (1) EBBR, Physics site-3 - Reviewed Data

    DOE Data Explorer

    Muradyan, Paytsar

    2018-03-14

    Sonic anemometers from Physics Site-3 and Site-9 provide wind components and virtual temperature. The energy balance Bowen ratio (EBBR) station at Physics site-3 provides measurements of the surface fluxes of latent and sensible heat, net radiation, and surface soil heat flux.

  8. Surface Meteorological Station - ANL 10m, (1) Sonic, Physics site-9 - Reviewed Data

    DOE Data Explorer

    Muradyan, Paytsar

    2018-03-14

    Sonic anemometers from Physics Site-3 and Site-9 provide wind components and virtual temperature. The energy balance Bowen ratio (EBBR) station at Physics site-3 provides measurements of the surface fluxes of latent and sensible heat, net radiation, and surface soil heat flux.

  9. Environmental evaluation of the electric and cogenerative configurations for the energy recovery of the Turin municipal solid waste incineration plant.

    PubMed

    Panepinto, Deborah; Genon, Giuseppe

    2014-07-01

    Given the desirability of reducing fossil fuel consumption, together with the increasing production of combustible solid wastes, there is clearly a need for waste treatment systems that achieve both volume reduction and energy recovery. Direct incineration method is one such system. The aim of this work was to analyze the municipal solid waste incineration plant currently under construction in the province of Turin (Piedmont, North Italy), especially the potential for energy recovery, and the consequent environmental effects. We analyzed two kinds of energy recovery: electric energy (electrical configuration) only, and both electric and thermal energy (cogenerative configuration), in this case with a different connection hypothesis to the district heating network. After we had evaluated the potential of the incinerator and considered local demographic, energy and urban planning effects, we assumed different possible connections to the district heating network. We computed the local and global environmental balances based on the characteristics of the flue gas emitted from the stack, taking into consideration the emissions avoided by the substituted sources. The global-scale results provided relevant information on the carbon dioxide emissions parameter. The results on the local scale were used as reference values for the implementation of a Gaussian model (Aermod) that allows evaluation of the actual concentration of the pollutants released into the atmosphere. The main results obtained highlight the high energy efficiency of the combined production of heat and electricity, and the opportunity to minimize the environmental impact by including cogeneration in a district heating scheme. © The Author(s) 2014.

  10. Malaria prevalence in Bata district, Equatorial Guinea: a cross-sectional study.

    PubMed

    Ncogo, Policarpo; Herrador, Zaida; Romay-Barja, Maria; García-Carrasco, Emely; Nseng, Gloria; Berzosa, Pedro; Santana-Morales, Maria A; Riloha, Matilde; Aparicio, Pilar; Valladares, Basilio; Benito, Agustín

    2015-11-16

    Malaria has traditionally been a leading public health problem in Equatorial Guinea. After completion, in September 2011, of the integrated set of interventions against malaria launched by the Global Fund Malaria Programme in the mainland area, the epidemiological situation of malaria remains unknown. The aim of this study was to investigate the prevalence rate of malaria and associated factors based on the rapid diagnosis test (RDT) in Bata district, in order to provide evidence that will reinforce the National Malaria Control Programme. From June to August 2013, a representative cross sectional survey using a multistage, stratified, cluster-selected sample was carried out in urban zones and rural villages from Bata district. Data on socio-demographic, health status and malaria-related behaviours was collected. Malaria diagnosis was performed by RDT. Bivariate and multivariable statistical methods were employed to assess malaria prevalence and its association with different factors. Prevalence of malaria was higher in rural settings (58.9 %; CI 95 % 55.2-62.5 %) than in the sampled urban communities (33.9 %; CI 95 % 31.1-36.9 %). Presence of anaemia was also high, especially in rural sites (89.6 vs. 82.8 %, p < 0.001). The analyses show that a positive RDT result was significantly associated with age group, the most affected age range being 13 months-14 years old. Other significant covariates were ethnic group (only in urban sites), number of adults living in the house (only in rural villages) previous history of fever, anaemia (only in urban sites) and sleeping under a bed net. Moreover, those who never slept under a bed net were two times more likely to have malaria. The prevalence of malaria was high in Bata district, especially in rural villages. The National Programme to fight malaria in Equatorial Guinea should take into account the differences found between rural and urban communities and age groups to target appropriately those worst affected. The findings of this study will assist in planning and undertaking regional policy and other preventive initiatives.

  11. Commercial Buildings Energy Consumption Survey 2012 - Detailed Tables

    EIA Publications

    2016-01-01

    The 2012 CBECS consumption and expenditures detailed tables are comprised of Tables C1-C38, which cover overall electricity, natural gas, fuel oil and district heat consumption, and tables E1-E11, which disaggregate the same energy sources by end use (heating, cooling, lighting, etc.). All of the detailed tables contain extensive row categories of building characteristics.

  12. Russia’s R&D for Low Energy Buildings: Insights for Cooperation with Russia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaaf, Rebecca E.; Evans, Meredydd

    Russian buildings, Russian buildings sector energy consumption. Russian government has made R&D investment a priority again. The government and private sector both invest in a range of building energy technologies. In particular, heating, ventilation and air conditioning, district heating, building envelope, and lighting have active technology research projects and programs in Russia.

  13. Effects of long-term climate change on global building energy expenditures

    DOE PAGES

    Clarke, Leon; Eom, Jiyong; Marten, Elke Hodson; ...

    2018-01-06

    Our paper explores potential future implications of climate change on building energy expenditures around the globe. Increasing expenditures result from increased electricity use for cooling, and are offset to varying degrees, depending on the region, by decreased energy consumption for heating. WE conducted an analysis using a model of the global buildings sector within the GCAM integrated assessment model. The integrated assessment framework is valuable because it represents socioeconomic and energy system changes that will be important for understanding building energy expenditures in the future. Results indicate that changes in net expenditures are not uniform across the globe. Net expendituresmore » decrease in some regions, such as Canada and Russia, where heating demands currently dominate, and increase the most in areas with less demand for space heating and greater demand for space cooling. We explain these results in terms of the basic drivers that link building energy expenditures to regional climate.« less

  14. Effects of long-term climate change on global building energy expenditures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clarke, Leon; Eom, Jiyong; Marten, Elke Hodson

    Our paper explores potential future implications of climate change on building energy expenditures around the globe. Increasing expenditures result from increased electricity use for cooling, and are offset to varying degrees, depending on the region, by decreased energy consumption for heating. WE conducted an analysis using a model of the global buildings sector within the GCAM integrated assessment model. The integrated assessment framework is valuable because it represents socioeconomic and energy system changes that will be important for understanding building energy expenditures in the future. Results indicate that changes in net expenditures are not uniform across the globe. Net expendituresmore » decrease in some regions, such as Canada and Russia, where heating demands currently dominate, and increase the most in areas with less demand for space heating and greater demand for space cooling. We explain these results in terms of the basic drivers that link building energy expenditures to regional climate.« less

  15. Solar energy system performance evaluation: Seasonal report for Contemporary Newman, Newman, Georgia

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A hot solar heating and hot water system's operational performance from June 1979 through April 1980 is evaluated. Solar energy satisfied 42 percent of the total measure load (hot water plus space heating), which was somewhat higher than the solar fraction of 32 percent. When system losses into the heating space from duct leaks and storage are included, the heating solar fraction increases from 42 to 64 percent. Net electrical energy savings were 5.47 million BTUs.

  16. Optimization of a heat-pipe-cooled space radiator for use with a reactor-powered Stirling engine

    NASA Technical Reports Server (NTRS)

    Moriarty, Michael P.; French, Edward P.

    1987-01-01

    The design optimization of a reactor-Stirling heat-pipe-cooled radiator is presented. The radiator is a self-deploying concept that uses individual finned heat pipe 'petals' to reject waste heat from a Stirling engine. Radiator optimization methodology is presented, and the results of a parametric analysis of the radiator design variables for a 100-kW(e) system are given. The additional steps of optiminzing the radiator resulted in a net system mass savings of 3 percent.

  17. Methods of increasing net work output of organic Rankine cycles for low-grade waste heat recovery with a detailed analysis using a zeotropic working fluid mixture and scroll expander

    NASA Astrophysics Data System (ADS)

    Woodland, Brandon Jay

    An organic Rankine cycle (ORC) is a thermodynamic cycle that is well-suited for waste heat recovery. It is generally employed for waste heat with temperatures in the range of 80 °C -- 300 °C. When the application is strictly to convert waste heat into work, thermal efficiency is not recommended as a key performance metric. In such an application, maximization of the net power output should be the objective rather than maximization of the thermal efficiency. Two alternative cycle configurations that can increase the net power produced from a heat source with a given temperature and flow rate are proposed and analyzed. These cycle configurations are 1) an ORC with two-phase flash expansion and 2) an ORC with a zeotropic working fluid mixture (ZRC). A design-stage ORC model is presented for consistent comparison of multiple ORC configurations. The finite capacity of the heat source and heat sink fluids is a key consideration in this model. Of all working fluids studied for the baseline ORC, R134a and R245fa yield the highest net power output from a given heat source. Results of the design-stage model indicate that the ORC with two-phase flash expansion offers the most improvement over the baseline ORC. However, the level of improvement that could be achieved in practice is highly uncertain due to the requirement of highly efficient two-phase expansion. The ZRC shows improvement over the baseline as long as the condenser fan power requirement is not negligible. At the highest estimated condenser fan power, the ZRC shows the most improvement, while the ORC with flash expansion is no longer beneficial. The ZRC was selected for detailed study because it does not require two-phase expansion. An experimental test rig was used to evaluate baseline ORC performance with R134a and with R245fa. The ZRC was tested on the same rig with a mixture of 62.5% R134a and 37.5% R245fa. The tested expander is a minimally-modified, of-the-shelf automotive scroll compressor. The high performance to cost ratio of this machine lends significant credence to the economic viability of small-scale, low-temperature ORCs. The experimental campaign covered two heat source temperatures, the full range of pump and expander speeds, a full range of heat source and heat sink fluid flow rates, and various charge levels for the three working fluids. This resulted in 366 steady-state measurements. The steady state measurements are used to develop a detailed ORC model. The model is based on multi-fluid performance maps for the pump and expander and a robust moving-boundary heat exchanger model. It is validated against the measured data and predicts the net power output of the tested ORC with a mean absolute percent error of 7.16%. Comparisons made with the detailed model confirm the predictions of the design-stage model. Using a conservative estimate of the condenser fan power, 19.1% improvement of the ZRC over the baseline ORC is indicated for a source temperature of 80 °C. For a 100 °C source temperature, 13.8% improvement is indicated. A key feature of the detailed ORC model is that it calculates the charge inventory of the working fluid in each heat exchanger and line set. Total system charge can also be specified as a model input. The model can represent the total charge well for R134a at low measured charge levels. As the measured charge level increases, the model becomes less accurate. Reasons for the deviation of the model at higher charge are investigated. It is expected that a charge tuning scheme could be employed to improve the accuracy of model-predicted charge.

  18. Feasibility and Supply Analysis of U.S. Geothermal District Heating and Cooling System

    NASA Astrophysics Data System (ADS)

    He, Xiaoning

    Geothermal energy is a globally distributed sustainable energy with the advantages of a stable base load energy production with a high capacity factor and zero SOx, CO, and particulates emissions. It can provide a potential solution to the depletion of fossil fuels and air pollution problems. The geothermal district heating and cooling system is one of the most common applications of geothermal energy, and consists of geothermal wells to provide hot water from a fractured geothermal reservoir, a surface energy distribution system for hot water transmission, and heating/cooling facilities to provide water and space heating as well as air conditioning for residential and commercial buildings. To gain wider recognition for the geothermal district heating and cooling (GDHC) system, the potential to develop such a system was evaluated in the western United States, and in the state of West Virginia. The geothermal resources were categorized into identified hydrothermal resources, undiscovered hydrothermal resources, near hydrothermal enhanced geothermal system (EGS), and deep EGS. Reservoir characteristics of the first three categories were estimated individually, and their thermal potential calculated. A cost model for such a system was developed for technical performance and economic analysis at each geothermally active location. A supply curve for the system was then developed, establishing the quantity and the cost of potential geothermal energy which can be used for the GDHC system. A West Virginia University (WVU) case study was performed to compare the competiveness of a geothermal energy system to the current steam based system. An Aspen Plus model was created to simulate the year-round campus heating and cooling scenario. Five cases of varying water flow rates and temperatures were simulated to find the lowest levelized cost of heat (LCOH) for the WVU case study. The model was then used to derive a levelized cost of heat as a function of the population density at a constant geothermal gradient. By use of such functions in West Virginia at a census tract level, the most promising census tracts in WV for the development of geothermal district heating and cooling systems were mapped. This study is unique in that its purpose was to utilize supply analyses for the GDHC systems and determine an appropriate economic assessment of the viability and sustainability of the systems. It was found that the market energy demand, production temperature, and project lifetime have negative effects on the levelized cost, while the drilling cost, discount rate, and capital cost have positive effects on the levelized cost by sensitivity analysis. Moreover, increasing the energy demand is the most effective way to decrease the levelized cost. The derived levelized cost function shows that for EGS based systems, the population density has a strong negative effect on the LCOH at any geothermal gradient, while the gradient only has a negative effect on the LCOH at a low population density.

  19. The significance of cloud-radiative forcing to the general circulation on climate time scales - A satellite interpretation

    NASA Technical Reports Server (NTRS)

    Sohn, Byung-Ju; Smith, Eric A.

    1992-01-01

    This paper focuses on the role of cloud- and surface-atmosphere forcing on the net radiation balance and their potential impact on the general circulation at climate time scales. The globally averaged cloud-forcing estimates and cloud sensitivity values taken from various recent studies are summarized. It is shown that the net radiative heating over the tropics is principally due to high clouds, while the net cooling in mid- and high latitudes is dominated by low and middle clouds.

  20. Experimental Investigation of Turbojet Thrust Augmentation Using an Ejector

    DTIC Science & Technology

    2007-03-01

    mechanisms in which a particle can exchange energy. Thrust augmenting devices can be divided into two categories: ones that exchange net work or heat and...two categories from the energy equation discussion above. Thrust augmentation is achieved through turbulent entrainment where work and/or heat is...front sustained by compression waves from a trailing reaction zone. A deflagration wave is a subsonic flame front sustained by heat transfer

  1. Coupled stochastic soil moisture simulation-optimization model of deficit irrigation

    NASA Astrophysics Data System (ADS)

    Alizadeh, Hosein; Mousavi, S. Jamshid

    2013-07-01

    This study presents an explicit stochastic optimization-simulation model of short-term deficit irrigation management for large-scale irrigation districts. The model which is a nonlinear nonconvex program with an economic objective function is built on an agrohydrological simulation component. The simulation component integrates (1) an explicit stochastic model of soil moisture dynamics of the crop-root zone considering interaction of stochastic rainfall and irrigation with shallow water table effects, (2) a conceptual root zone salt balance model, and 3) the FAO crop yield model. Particle Swarm Optimization algorithm, linked to the simulation component, solves the resulting nonconvex program with a significantly better computational performance compared to a Monte Carlo-based implicit stochastic optimization model. The model has been tested first by applying it in single-crop irrigation problems through which the effects of the severity of water deficit on the objective function (net benefit), root-zone water balance, and irrigation water needs have been assessed. Then, the model has been applied in Dasht-e-Abbas and Ein-khosh Fakkeh Irrigation Districts (DAID and EFID) of the Karkheh Basin in southwest of Iran. While the maximum net benefit has been obtained for a stress-avoidance (SA) irrigation policy, the highest water profitability has been resulted when only about 60% of the water used in the SA policy is applied. The DAID with respectively 33% of total cultivated area and 37% of total applied water has produced only 14% of the total net benefit due to low-valued crops and adverse soil and shallow water table conditions.

  2. Evaluation of satellite and reanalysis‐based global net surface energy flux and uncertainty estimates

    PubMed Central

    Allan, Richard P.; Mayer, Michael; Hyder, Patrick; Loeb, Norman G.; Roberts, Chris D.; Valdivieso, Maria; Edwards, John M.; Vidale, Pier‐Luigi

    2017-01-01

    Abstract The net surface energy flux is central to the climate system yet observational limitations lead to substantial uncertainty. A combination of satellite‐derived radiative fluxes at the top of atmosphere adjusted using the latest estimation of the net heat uptake of the Earth system, and the atmospheric energy tendencies and transports from the ERA‐Interim reanalysis are used to estimate surface energy flux globally. To consider snowmelt and improve regional realism, land surface fluxes are adjusted through a simple energy balance approach at each grid point. This energy adjustment is redistributed over the oceans to ensure energy conservation and maintain realistic global ocean heat uptake, using a weighting function to avoid meridional discontinuities. Calculated surface energy fluxes are evaluated through comparison to ocean reanalyses. Derived turbulent energy flux variability is compared with the Objectively Analyzed air‐sea Fluxes (OAFLUX) product, and inferred meridional energy transports in the global ocean and the Atlantic are also evaluated using observations. Uncertainties in surface fluxes are investigated using a variety of approaches including comparison with a range of atmospheric reanalysis products. Decadal changes in the global mean and the interhemispheric energy imbalances are quantified, and present day cross‐equator heat transports are reevaluated at 0.22 ± 0.15 PW (petawatts) southward by the atmosphere and 0.32 ± 0.16 PW northward by the ocean considering the observed ocean heat sinks. PMID:28804697

  3. Biomass universal district heating systems

    NASA Astrophysics Data System (ADS)

    Soltero, Victor Manuel; Rodríguez-Artacho, Salvador; Velázquez, Ramón; Chacartegui, Ricardo

    2017-11-01

    In mild climate regions Directive 27/2012 EU application for developing sustainable district heating networks in consolidated urban nucleus is a challenge. In Spain most of the municipalities above 5,000 inhabitants have a reliable natural gas network and individual heating systems at homes. In this work a new heating network paradigm is proposed, the biomass universal heating network in rural areas. This model involves all the economic, legal and technical aspects and interactions between the different agents of the systems: provider company, individual and collective end-users and local and regional administration. The continental region in Spain has 588 municipalities with a population above 1,500 inhabitants close to forest biomass with renewable use. In many of these cases the regulation identifies the ownership of the forest resources use. The universal heating networks are a great opportunity for energy saving of 2,000 GWh, avoiding 2.7 million tons of CO2 emissions and with a global annual savings for end users of 61.8 million of euros. The presented model is easily extrapolated to other small municipalities in Europe. The real application of the model is presented for three municipalities in different locations of Spain where Universal Heating Networks are under development. The analysis show the interest of the integrated model for the three cases with different structural agents and relationships between them. The use of sustainable forest resources, extracted and managed by local companies, strengths circular economy in the region with a potential global economic impact above 200 M€.

  4. Klamath Falls downtown development geothermal sidewalk snowmelt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, B.

    1995-10-01

    The Klamuth Falls, Oregon, downtown has seen a period of decline over the past 20 years as businesses have moved to new suburban shopping centers. Downtown business owners and the Klamuth Falls Downtown Redevelopment Agency are working to reverse that trend with a Downtown Streetscape Project intended to make the downtown a more pleasant place to work and do business. The visible elements of the project include new crosswalks with brick pavers, wheelchair ramps at sidewalk corners, new concrete sidewalks with a consistent decorative grid pattern, sidewalk planters for trees and flowers, and antique-style park benches and lighting fixtures. Amore » less visible, but equally valuable feature of the project is the plastic tubing installed under the sidewalks, wheelchair ramps and crosswalks, designed to keep them snow and ice free in the winter. A unique feature of the snowmelt system is the use of geothermal heated water on the return side of the Klamath Falls Geothermal District Heating System, made possible by the recent expansion of the district heating system.« less

  5. Coupled heat and fluid flow modeling of the Carboniferous Kuna Basin, Alaska: Implications for the genesis of the Red Dog Pb-Zn-Ag-Ba ore district

    USGS Publications Warehouse

    Garven, G.; Raffensperger, Jeff P.; Dumoulin, Julie A.; Bradley, D.A.; Young, L.E.; Kelley, K.D.; Leach, D.L.

    2003-01-01

    The Red Dog deposit is a giant 175 Mton (16% Zn, 5% Pb), shale-hosted Pb-Zn-Ag-Ba ore district situated in the Carboniferous Kuna Basin, Western Brooks Range, Alaska. These SEDEX-type ores are thought to have formed in calcareous turbidites and black mudstone at elevated sub-seafloor temperatures (120-150??C) within a hydrogeologic framework of submarine convection that was structurally organized by large normal faults. The theory for modeling brine migration and heat transport in the Kuna Basin is discussed with application to evaluating flow patterns and heat transport in faulted rift basins and the effects of buoyancy-driven free convection on reactive flow and ore genesis. Finite element simulations show that hydrothermal fluid was discharged into the Red Dog subbasin during a period of basin-wide crustal heat flow of 150-160 mW/m2. Basinal brines circulated to depths as great as 1-3 km along multiple normal faults flowed laterally through thick clastic aquifers acquiring metals and heat, and then rapidly ascended a single discharge fault zone at rates ??? 5 m/year to mix with seafloor sulfur and precipitate massive sulfide ores. ?? 2003 Elsevier Science B.V. All rights reserved.

  6. Heat transfer in melt ponds with convection and radiative heating: observationally-inspired modelling

    NASA Astrophysics Data System (ADS)

    Wells, A.; Langton, T.; Rees Jones, D. W.; Moon, W.; Kim, J. H.; Wilkinson, J.

    2016-12-01

    Melt ponds have key impacts on the evolution of Arctic sea ice and summer ice melt. Small changes to the energy budget can have significant consequences, with a net heat-flux perturbation of only a few Watts per square metre sufficient to explain the thinning of sea ice over recent decades. Whilst parameterisations of melt-pond thermodynamics often assume that pond temperatures remain close to the freezing point, recent in-situ observations show more complex thermal structure with significant diurnal and synoptic variability. We here consider the energy budget of melt ponds and explore the role of internal convective heat transfer in determining the thermal structure within the pond in relatively calm conditions with low winds. We quantify the energy fluxes and temperature variability using two-dimensional direct numerical simulations of convective turbulence within a melt pond, driven by internal radiative heating and surface fluxes. Our results show that the convective flow dynamics are modulated by changes to the incoming radiative flux and sensible heat flux at the pond surface. The evolving pond surface temperature controls the outgoing longwave emissions from the pond. Hence the convective flow modifies the net energy balance of a melt pond, modulating the relative fractions of the incoming heat flux that is re-emitted to the atmosphere or transferred downward into the sea ice to drive melt.

  7. Development and Analysis of New Integrated Energy Systems for Sustainable Buildings

    NASA Astrophysics Data System (ADS)

    Khalid, Farrukh

    Excessive consumption of fossil fuels in the residential sector and their associated negative environmental impacts bring a significant challenge to engineers within research and industrial communities throughout the world to develop more environmentally benign methods of meeting energy needs of residential sector in particular. This thesis addresses potential solutions for the issue of fossils fuel consumption in residential buildings. Three novel renewable energy based multigeneration systems are proposed for different types of residential buildings, and a comprehensive assessment of energetic and exergetic performances is given on the basis of total occupancy, energy load, and climate conditions. System 1 is a multigeneration system based on two renewable energy sources. It uses biomass and solar resources. The outputs of System 1 are electricity, space heating, cooling, and hot water. The energy and exergy efficiencies of System 1 are 91.0% and 34.9%, respectively. The results of the optimisation analysis show that the net present cost of System 1 is 2,700,496 and that the levelised cost of electricity is 0.117/kWh. System 2 is a multigeneration system, integrating three renewable energy based subsystems; wind turbine, concentrated solar collector, and Organic Rankine Cycle supplied by a ground source heat exchanger. The outputs of the System 2 are electricity, hot water, heating and cooling. The optimisation analysis shows that net present cost is 35,502 and levelised cost of electricity is 0.186/kWh. The energy and exergy efficiencies of System 2 are found to be 34.6% and 16.2%, respectively. System 3 is a multigeneration system, comprising two renewable energy subsystems-- geothermal and solar to supply power, cooling, heating, and hot water. The optimisation analysis shows that the net present cost of System 3 is 598,474, and levelised cost of electricity of 0.111/kWh. The energy and exergy efficiencies of System 3 are 20.2% and 19.2%, respectively, with outputs of electricity, hot water, cooling and space heating. A performance assessment for identical conditions indicates that System 3 offers the best performance, with the minimum net present cost of 26,001 and levelised cost of electricity of 0.136/kWh.

  8. High Temperature Superconducting State in Metallic Nanoclusters and Nano-Based Systems

    DTIC Science & Technology

    2011-10-01

    ac.Semenova, 1a Chernogolovka, Moscow District, Russia 142432 EOARD ISTC 09-7006 (Project Number 4084p) October 2011 Interim Report for 01...Nano-Based Systems 5a. CONTRACT NUMBER ISTC Registration No: 4084p 5b. GRANT NUMBER ISTC 09-7006 5c. PROGRAM ELEMENT NUMBER 6...Keywords: Superconductivity, tunneling, creep, resonance tunneling, clusters, nets, fluctuations, phase transitions. ISTC № 4084p

  9. Do At-Risk Students Benefit When NovaNET Is Used for Credit Recovery?

    ERIC Educational Resources Information Center

    Volkerding, Rebecca Lynn

    2012-01-01

    The purpose of this study was to determine if it is effective and appropriate to place all students needing credit recovery in computer-based classes regardless of age, risk ratio, and their previous failing grade. Driven by the NCLB mandate for schools to produce greater gains and graduate all students in 4.5 years, districts are now using online…

  10. Challenges in the Decentralization of Recruitment and Selection of Teachers in Kenyan Secondary Schools: A Case of Gucha District

    ERIC Educational Resources Information Center

    Moraa, Samba Serah; Chepkoech, Koske Luciana; Simiyu, Mulongo Leonard

    2017-01-01

    Decentralization of teacher recruitment and selection in Kenya was as a result of World Bank/IMF policies, which support projects that guarantee direct net economic returns by productivity and indirect returns on externalities. The approach has been used as a way of improving service delivery. This strategy that has been successful elsewhere may…

  11. Cost-benefit study of school nursing services.

    PubMed

    Wang, Li Yan; Vernon-Smiley, Mary; Gapinski, Mary Ann; Desisto, Marie; Maughan, Erin; Sheetz, Anne

    2014-07-01

    In recent years, across the United States, many school districts have cut on-site delivery of health services by eliminating or reducing services provided by qualified school nurses. Providing cost-benefit information will help policy makers and decision makers better understand the value of school nursing services. To conduct a case study of the Massachusetts Essential School Health Services (ESHS) program to demonstrate the cost-benefit of school health services delivered by full-time registered nurses. Standard cost-benefit analysis methods were used to estimate the costs and benefits of the ESHS program compared with a scenario involving no school nursing service. Data from the ESHS program report and other published studies were used. A total of 477 163 students in 933 Massachusetts ESHS schools in 78 school districts received school health services during the 2009-2010 school year. School health services provided by full-time registered nurses. Costs of nurse staffing and medical supplies incurred by 78 ESHS districts during the 2009-2010 school year were measured as program costs. Program benefits were measured as savings in medical procedure costs, teachers' productivity loss costs associated with addressing student health issues, and parents' productivity loss costs associated with student early dismissal and medication administration. Net benefits and benefit-cost ratio were calculated. All costs and benefits were in 2009 US dollars. During the 2009-2010 school year, at a cost of $79.0 million, the ESHS program prevented an estimated $20.0 million in medical care costs, $28.1 million in parents' productivity loss, and $129.1 million in teachers' productivity loss. As a result, the program generated a net benefit of $98.2 million to society. For every dollar invested in the program, society would gain $2.20. Eighty-nine percent of simulation trials resulted in a net benefit. The results of this study demonstrated that school nursing services provided in the Massachusetts ESHS schools were a cost-beneficial investment of public money, warranting careful consideration by policy makers and decision makers when resource allocation decisions are made about school nursing positions.

  12. Inter-Annual Variability in Stream Water Temperature, Microclimate and Heat Exchanges: a Comparison of Forest and Moorland Environments

    NASA Astrophysics Data System (ADS)

    Garner, G.; Hannah, D. M.; Malcolm, I.; Sadler, J. P.

    2012-12-01

    Riparian forest is recognised as important for moderating stream temperature variability and has the potential to mitigate thermal extremes in a changing climate. Previous research on the heat exchanges controlling water column temperature has often been short-term or seasonally-constrained, with the few multi-year studies limited to a maximum of two years. This study advances previous work by providing a longer-term perspective which allows assessment of inter-annual variability in stream temperature, microclimate and heat exchange dynamics between a semi-natural woodland and a moorland (no trees) reach of the Girnock Burn, a tributary of the Scottish Dee. Automatic weather stations collected 15-minute data over seven consecutive years, which to our knowledge is a unique data set in providing the longest term perspective to date on stream temperature, microclimate and heat exchange processes. Results for spring-summer indicate that the presence of a riparian canopy has a consistent effect between years in reducing the magnitude and variability of mean daily water column temperature and daily net energy totals. Differences in the magnitude and variability in net energy fluxes between the study reaches were driven primarily by fluctuations in net radiation and latent heat fluxes in response to between- and within-year variability in growth of the riparian forest canopy at the forest and prevailing weather conditions at both the forest and moorland. This research provides new insights on the inter-annual variability of stream energy exchanges for moorland and forested reaches under a wide range of climatological and hydrological conditions. The findings therefore provide a more robust process basis for modelling the impact of changes in forest practice and climate change on river thermal dynamics.

  13. Wall System Saves Initial HVAC Costs

    ERIC Educational Resources Information Center

    Modern Schools, 1976

    1976-01-01

    The superior insulating characteristics of an exterior wall system has enabled a Massachusetts school district to realize a savings on electric heating, ventilating, and air-conditioning systems. (Author/MLF)

  14. Micronized coal-fired retrofit system for SO{sub x} reduction: Krakow Clean Fossil Fuels and Energy Efficiency Program. Technical progress report No. 3, October 1996--December 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The PROJECT proposes to install a new TCS micronized coal-fired heating plant for the Produkcja I Hodowla Roslin Ogrodniczych (PHRO) Greenhouse Complex; Krzeszowice, Poland (about 20 miles west of Krakow). PHRO currently utilizes 14 heavy oil-fired boilers to produce heat for its greenhouse facilities and also home heating to several adjacent apartment housing complexes. The boilers currently burn a high-sulfur content heavy crude oil, called Mazute. For size orientation, the PHRO Greenhouse complex grows a variety of vegetables and flowers for the Southern Poland marketplace. The greenhouse area under glass is very large and equivalent to approximately 50 football fields.more » The new micronized coal fired boiler would: (1) provide a significant portion of the heat for PHRO and a portion of the adjacent apartment housing complexes, (2) dramatically reduce sulfur dioxide air pollution emissions, while satisfying new Polish air regulations, and (3) provide attractive savings to PHRO, based on the quantity of displaced oil. Currently, the Town of Krzeszowice is considering a district heating program that would replace some, or all, of the 40 existing small in-town heating boilers that presently burn high-sulfur content coal. Potentially the district heating system can be expanded and connected into the PHRO boiler network; so that, PHRO boilers can supply all, or a portion of, the Town`s heating demand. The new TCS micronized coal system could provide a portion of this demand.« less

  15. Transformations, Inc.: Partnering to Build Net-Zero Energy Houses in Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Bergey, D.; Wytrykowska, H.

    Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ('Devens'), The Homes at Easthampton Meadow ('Easthampton') andPhase II of the Coppersmith Way Development ('Townsend'). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers tomore » specific research questions for homes with high R double stud walls and high efficiency ductlessair source heat pump systems ('mini-splits'); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.« less

  16. Transformations, Inc.. Partnering To Build Net-Zero Energy Houses in Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Bergey, D.; Wytrykowska, H.

    Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ("Devens"), The Homes at Easthampton Meadow ("Easthampton") and Phase II of the Coppersmith Way Development ("Townsend"). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answersmore » to specific research questions for homes with high R double stud walls and high efficiency ductless air source heat pump systems ("mini-splits"); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.« less

  17. Environmental Loss Characterization of an Advanced Stirling Convertor (ASC-E2) Insulation Package Using a Mock Heater Head

    NASA Technical Reports Server (NTRS)

    Schifer, Nicholas A.; Briggs, Maxwell H.

    2012-01-01

    The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two highefficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a specified electrical power output for a given net heat input. While electrical power output can be precisely quantified, thermal power input to the Stirling cycle cannot be directly measured. In an effort to improve net heat input predictions, the Mock Heater Head was developed with the same relative thermal paths as a convertor using a conducting rod to represent the Stirling cycle and tested to provide a direct comparison to numerical and empirical models used to predict convertor net heat input. The Mock Heater Head also served as the pathfinder for a higher fidelity version of validation test hardware, known as the Thermal Standard. This paper describes how the Mock Heater Head was tested and utilized to validate a process for the Thermal Standard.

  18. Elements de conception d'un systeme geothermique hybride par optimisation financiere

    NASA Astrophysics Data System (ADS)

    Henault, Benjamin

    The choice of design parameters for a hybrid geothermal system is usually based on current practices or questionable assumptions. In fact, the main purpose of a hybrid geothermal system is to maximize the energy savings associated with heating and cooling requirements while minimizing the costs of operation and installation. This thesis presents a strategy to maximize the net present value of a hybrid geothermal system. This objective is expressed by a series of equations that lead to a global objective function. Iteratively, the algorithm converges to an optimal solution by using an optimization method: the conjugate gradient combined with a combinatorial method. The objective function presented in this paper makes use of a simulation algorithm for predicting the fluid temperature of a hybrid geothermal system on an hourly basis. Thus, the optimization method selects six variables iteratively, continuous and integer type, affecting project costs and energy savings. These variables are the limit temperature at the entry of the heat pump (geothermal side), the number of heat pumps, the number of geothermal wells and the distance in X and Y between the geothermal wells. Generally, these variables have a direct impact on the cost of the installation, on the entering water temperature at the heat pumps, the cost of equipment, the thermal interference between boreholes, the total capacity of geothermal system, on system performance, etc. On the other hand, the arrangement of geothermal wells is variable and is often irregular depending on the number of selected boreholes by the algorithm. Removal or addition of one or more borehole is guided by a predefined order dicted by the designer. This feature of irregular arrangement represents an innovation in the field and is necessary for the operation of this algorithm. Indeed, this ensures continuity between the number of boreholes allowing the use of the conjugate gradient method. The proposed method provides as outputs the net present value of the optimal solution, the position of the vertical boreholes, the number of installed heat pumps, the limits of entering water temperature at the heat pumps and energy consumption of the hybrid geothermal system. To demonstrate the added value of this design method, two case studies are analyzed, for a commercial building and a residential. The two studies allow to conclude that: the net present value of hybrid geothermal systems can be significantly improved by the choice of right specifications; the economic value of a geothermal project is strongly influenced by the number of heat pumps and the number of geothermal wells or the temperature limit in heating mode; the choice of design parameters should always be driven by an objective function and not by the designer; peak demand charges favor hybrid geothermal systems with a higher capacity. Then, in order to validate the operation, this new design method is compared to the standard sizing method which is commonly used. By designing the hybrid geothermal system according to standard sizing method and to meet 70% of peak heating, the net present value over 20 years for the residential project is negative, at -61,500 while it is 43,700 for commercial hybrid geothermal system. Using the new design method presented in this thesis, the net present values of projects are respectively 162,000 and 179,000. The use of this algorithm is beneficial because it significantly increases the net present value of projects. The research presented in this thesis allows to optimize the financial performance of hybrid geothermal systems. The proposed method will allow industry stakeholders to increase the profitability of their projects associated with low temperature geothermal energy.

  19. A study of the surface energy balance on slopes in a tallgrass prairie

    NASA Technical Reports Server (NTRS)

    Nie, D.; Demetriades-Shah, T.; Kanemasu, E. T.

    1990-01-01

    Four slopes (north, south, east, and west) were selected on the Konza Prairie Research Natural Area to study the effect of topography on surface energy balance and other micrometeorological variables. Energy fluxes, air temperature, and vapor pressure were measured on the sloped throughout the 1988 growing season. Net radiation was the highest on the south-facing slope and lowest on the north-facing slope, and the difference was more than 150 W/sq m (20 to 30 percent) at solar noon. For daily averages, the difference was 25 W/sq m (15 percent) early in the season and increased to 60 W/sq m (30 to 50 percent) in September. The east-facing and west-facing slopes had the same daily average net radiation, but the time of day when maximum net radiation occurred was one hour earlier for the east-facing slope and one hour later for the west-facing slope relative to solar noon. Soil heat fluxes were similar for all the slopes. The absolute values of sensible heat flux (h) was consistently lower on the north-facing slope compared with other slopes. Typical difference in the values of H between the north-facing and the south-facing slopes was 15 to 30 W/sq m. The south-facing slope had the greatest day to day fluctuation in latent heat flux as a result of interaction of net radiation, soil moisture, and green leaf area. The north-facing slope had higher air temperatures during the day and higher vapor pressures both during the day and at night when the wind was from the south.

  20. Assessment of Global Annual Atmospheric Energy Balance from Satellite Observations

    NASA Technical Reports Server (NTRS)

    Lin, Bing; Stackhouse, Paul; Minnis, Patrick; Wielicki, Bruce A.; Hu, Yongxiang; Sun, Wenbo; Fan, Tai-Fang (Alice); Hinkelman, Laura

    2008-01-01

    Global atmospheric energy balance is one of the fundamental processes for the earth's climate system. This study uses currently available satellite data sets of radiative energy at the top of atmosphere (TOA) and surface and latent and sensible heat over oceans for the year 2000 to assess the global annual energy budget. Over land, surface radiation data are used to constrain assimilated results and to force the radiation, turbulent heat, and heat storage into balance due to a lack of observation-based turbulent heat flux estimations. Global annual means of the TOA net radiation obtained from both direct measurements and calculations are close to zero. The net radiative energy fluxes into the surface and the surface latent heat transported into the atmosphere are about 113 and 86 Watts per square meter, respectively. The estimated atmospheric and surface heat imbalances are about -8 9 Watts per square meter, values that are within the uncertainties of surface radiation and sea surface turbulent flux estimates and likely systematic biases in the analyzed observations. The potential significant additional absorption of solar radiation within the atmosphere suggested by previous studies does not appear to be required to balance the energy budget the spurious heat imbalances in the current data are much smaller (about half) than those obtained previously and debated at about a decade ago. Progress in surface radiation and oceanic turbulent heat flux estimations from satellite measurements significantly reduces the bias errors in the observed global energy budgets of the climate system.

  1. Closure of the energy balance equation over bare soil during the formation and evaporation of non-rainfall water inputs

    NASA Astrophysics Data System (ADS)

    Florentin, Anat; Agam, Nurit

    2015-04-01

    The Negev desert is characterized by an arid climate (annual mean precipitation is 90 mm) with sea breeze carrying moisture from the Mediterranean Sea during the afternoon regularly. Non-rainfall water inputs (NRWIs) are thus of great importance to the hydrometeorology and the ecological functioning of the region. The small magnitude of NRWIs challenges attempts to quantify these processes. The aim of this research was to test commonly used micrometeorological methods to quantify the energy balance components during the deposition and evaporation of NRWIs. A fully equipped micrometeorological station was set up near the Blaustein Institutes for Desert Research of the Ben-Gurion University of the Negev (30o 51' 35.6" N; 34o 46' 24.8" E) during September-October 2014. Net-radiation was measured with a 4-way net radiometer, and soil heat flux was quantified by the calorimetric method in three replicates. Latent heat was measured using an eddy-covariance (EC) and compared to a micro-lysimeter (ML); sensible heat flux was measured with an EC and a surface layer scintillometer (SLS). Sensible heat fluxes measured by the EC and the SLS showed good agreement. EC latent heat fluxes were in good agreement with those derived by the ML. Nevertheless, derivation of latent heat flux from the SLS measurements through the energy balance equation showed a relatively large deviation from the directly measured latent heat flux. This deviation is likely attributed to measurement errors of the soil heat flux.

  2. Subcontracted activities related to TES for building heating and cooling

    NASA Technical Reports Server (NTRS)

    Martin, J.

    1980-01-01

    The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

  3. Heating Has No Effect on the Net Protein Utilisation from Egg Whites in Rats.

    PubMed

    Matsuoka, Ryosuke; Takahashi, Yayoi; Kimura, Mamoru; Masuda, Yasunobu; Kunou, Masaaki

    2017-01-01

    Egg whites (EW) are a good source of protein; however, they are typically heated prior to consumption. Therefore, we investigated the effects of different heating conditions on the protein utilisation rate of EW. Male Sprague-Dawley rats ( n = 36, 198 ± 1 g) were divided into six groups and fed American Institute of Nutrition-76 chow containing unheated EW, soft-boiled EW, boiled EW, milk whey protein, soybean protein, or no protein over a 10-day period using pair-feeding. Urine and faeces were sampled daily beginning on day 5 to measure nitrogen content and the net protein utilisation (NPU) rate. The soybean protein group had a significantly lower level of food intake and was thus excluded from subsequent analyses. The NPU value was similar among the unheated, soft-boiled, and boiled EW groups (97.5 ± 0.4, 96.5 ± 0.1, and 96.5 ± 0.7, resp.). The EW group values were significantly higher than the whey group values (90.5 ± 1.0). These results show that EW serve as a good source of protein, irrespective of heating.

  4. Assessment of the water and energy budget simulation of three land surface models: CLM4.5, CoLM2014, and CoLM2005

    NASA Astrophysics Data System (ADS)

    Li, C.; Lu, H.; Wen, X.

    2015-12-01

    Land surface model (LSM), which simulates energy, water and momentum exchanges between land and atmosphere, is an important component of Earth System Models (ESM). As shown in CMIP5, different ESMs usually use different LSMs and represent various land surface status. In order to select a land surface model which could be embedded into the ESM developed in Tsinghua University, we firstly evaluate the performance of three LSMs: Community Land Model (CLM4.5) and two different versions of Common Land Model (CoLM2005 and CoLM2014). All of three models were driven by CRUNCEP data and simulation results from 1980 to 2010 were used in this study. Diagnostic data provided by NCAR, global latent and sensible heat flux map estimated by Jung, net radiation from SRB, and in situ observation collected from FluxNet were used as reference data. Two variables, surface runoff and snow depth, were used for evaluating the model performance in water budget simulation, while three variables including net radiation, sensible heat, and latent heat were used for assessing energy budget simulation. For 30 years averaged runoff, global average value of Colm2014 is 0.44mm/day and close to the diagnostic value of 0.75 mm/day, while that of Colm2005 is 0.44mm/day and that of CLM is 0.20mm/day. For snow depth simulation, three models all have overestimation in the Northern Hemisphere and underestimation in the Southern Hemisphere compare to diagnostic data. For 30 years energy budget simulation, at global scale, CoLM2005 performs best in latent heat estimation, CoLM2014 performs best in sensible heat simulation, and CoLM2005 and CoLM2014 make similar performance in net radiation estimation but is still better than CLM. At regional and local scale, comparing to the four years average of flux tower observation, RMSE of CoLM2005 is the smallest for latent heat (9.717 W/m2) , and for sensible heat simulation, RMSE of CoLM2005 (13.048 W/m2) is slightly greater than CLM(10.767 W/m2) but still better than CoLM2014(30.085 W/m2). Our analysis shows that both CoLM 2005 and CoLM 2014 are able to reproduce comparable land surface water and energy fluxes. It implies that the ESM developed in Tsinghua University may use CoLM, a LSM developed and maintained in China, as the land surface component. .

  5. Assessing the impacts of changes in treatment technology on energy and greenhouse gas balances for organic waste and wastewater treatment using historical data.

    PubMed

    Poulsen, Tjalfe G; Hansen, Jens Aage

    2009-11-01

    Historical data on organic waste and wastewater treatment during the period of 1970-2020 were used to assess the impact of treatment on energy and greenhouse gas (GHG) balances. The assessment included the waste fractions: Sewage sludge, food waste, yard waste and other organic waste (paper, plastic, etc.). Data were collected from Aalborg, a municipality located in Northern Denmark. During the period from 1970-2005, Aalborg Municipality has changed its waste treatment strategy from landfilling of all wastes toward composting of yard waste and incineration with combined heat and power production from the remaining organic municipal waste. Wastewater treatment has changed from direct discharge of untreated wastewater to full organic matter and nutrient (N, P) removal combined with anaerobic digestion of the sludge for biogas production with power and heat generation. These changes in treatment technology have resulted in the waste and wastewater treatment systems in Aalborg progressing from being net consumers of energy and net emitters of GHG, to becoming net producers of energy and net savers of GHG emissions (due to substitution of fossil fuels elsewhere). If it is assumed that the organic waste quantity and composition is the same in 1970 and 2005, the technology change over this time period has resulted in a progression from a net annual GHG emission of 200 kg CO( 2)-eq. capita(-1) in 1970 to a net saving of 170 kg CO(2)-eq. capita(-1) in 2005 for management of urban organic wastes.

  6. An Excel Spreadsheet Model for States and Districts to Assess the Cost-Benefit of School Nursing Services.

    PubMed

    Wang, Li Yan; O'Brien, Mary Jane; Maughan, Erin D

    2016-11-01

    This paper describes a user-friendly, Excel spreadsheet model and two data collection instruments constructed by the authors to help states and districts perform cost-benefit analyses of school nursing services delivered by full-time school nurses. Prior to applying the model, states or districts need to collect data using two forms: "Daily Nurse Data Collection Form" and the "Teacher Survey." The former is used to record daily nursing activities, including number of student health encounters, number of medications administered, number of student early dismissals, and number of medical procedures performed. The latter is used to obtain estimates for the time teachers spend addressing student health issues. Once inputs are entered in the model, outputs are automatically calculated, including program costs, total benefits, net benefits, and benefit-cost ratio. The spreadsheet model, data collection tools, and instructions are available at the NASN website ( http://www.nasn.org/The/CostBenefitAnalysis ).

  7. Assessment of safety-relevant aspects of Kraftwerk Union's 200-MW(thermal) nuclear district heating plant concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erlenwein, P.; Frisch, W.; Kafka, P.

    Nuclear reactors of 200- to 400-MW(thermal) power for district heating are the subject of increasing interest, and several specific designs are under discussion today. In the Federal Republic of Germany (FRG), the Kraftwerk Union AG has presented a 200-MW(thermal) heating reactor concept. The main safety issues of this design are assessed. In this design, the primary system is fully integrated into the reactor pressure vessel (RPV), which is tightly enclosed by the containment. The low process parameters like pressure, temperature, and power density and the high ratio of coolant volume to thermal power allow the design of simple safety features.more » This is supported by the preference of passive over active components. A special feature is a newly designed hydraulic control and rod drive mechanism, which is also integrated into the RPV. Within the safety assessment an overview of the relevant FRG safety rules and guidelines, developed mainly for large, electricity-generating power plants, is given. Included is a discussion of the extent to which these licensing rules can be applied to the concept of heating reactors.« less

  8. Geothermal direct use in the United States update: 1990-1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lienau, P.J.; Lund, J.W.; Culver, G.G.

    1995-02-01

    Geothermal energy is estimated to currently supply approximately 13,885 TJ/yr (13,180 x 10{sup 9} BTU/yr) of heat energy through direct heat applications in the United States. Table 1 summarizes the U.S. geothermal direct heat uses. It should be noted that Table 1 does not contain enhanced oil recovery, which was included in the 1990 update report. In the oil fields of the upper midwest (Montana, North Dakota and Wyoming), thermal waters are not being injected at higher temperatures than the oil producing zones. This means that there is no benefit to reducing oil viscosity, which would have increased production rates;more » therefore, resulting in this use being deleted from direct uses in the table. In the 1990 report two geothermal district heating systems were listed as under construction, Mammoth Lakes and Bridgeport, these systems have not been built although exploratory wells have been drilled. They are not included in the current summary of direct uses. There have been no new geothermal district heating systems started; however, San Bernardino and Klamath Falls have expanded their systems. Annual energy use of direct heat applications reported for both the 1990 and 1994 updates are shown. All of the categories experienced some increase in use, however the largest growth has been in geothermal heat pumps. From 1985 to 1990 the highest growth rate in geothermal heat pumps occurred, then tapered off some from 1990 to 1994. In the other five categories there has been a steady growth with the largest occurring in space heating, greenhouses and industrial plants. Greenhouse development has been significant in New Mexico and Utah and a new onion and garlic dehydration plant was built in Nevada.« less

  9. Concentrating Solar Power Projects - Lebrija 1 | Concentrating Solar Power

    Science.gov Websites

    Turbine Capacity: Net: 50.0 MW Gross: 50.0 MW Status: Operational Start Year: 2011 Do you have more : Solel Heat-Transfer Fluid Type: Therminol VP1 Solar-Field Outlet Temp: 395°C Power Block Turbine Capacity (Gross): 50.0 MW Turbine Capacity (Net): 50.0 MW Power Cycle Pressure: 100.0 bar Cooling Method

  10. Solar energy system demonstration project at Wilmington Swim School, New Castle, Delaware

    NASA Astrophysics Data System (ADS)

    1980-07-01

    A solar energy system located at the Wilmington Swim School, New Castle, Delaware is described. The system was designed for a 40 percent heating and a 30 percent hot water solar contribution serving the heat loads in the following order: space heat - new addition, domestic water - entire facility, and pool heating - entire facility. On a cost basis for 2920 hours of operation, the heat reclaimed would cost $969.66 annually if provided by gas at 3.79 per million Btu's. At 5.5 centers per kwh, heat recovery costs of $481.80 percent a net savings of $487.86 annually.

  11. Solar energy system demonstration project at Wilmington Swim School, New Castle, Delaware

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A solar energy system located at the Wilmington Swim School, New Castle, Delaware is described. The system was designed for a 40 percent heating and a 30 percent hot water solar contribution serving the heat loads in the following order: space heat - new addition, domestic water - entire facility, and pool heating - entire facility. On a cost basis for 2920 hours of operation, the heat reclaimed would cost $969.66 annually if provided by gas at 3.79 per million Btu's. At 5.5 centers per kwh, heat recovery costs of $481.80 percent a net savings of $487.86 annually.

  12. Various methods of heat supply for a building which is operated periodically during the year

    NASA Astrophysics Data System (ADS)

    Małetka, Marek; Laska, Marta

    2017-11-01

    Stand-alone buildings operated periodically require heat supply for hot water and heating purposes to be carefully analyzed in terms of the technical capabilities, the energy and financial outlays. The paper presents the analysis of heat supply for hot water purposes and central heating in the stand-alone cloakroom building located in Poland. The analysis is undertaken for different variants of heat delivery for a building from electric heaters, gas boiler and district heating solutions to renewable sources applications, namely solar panels and heat pumps. For each solution, usage of usable, final and primary energy was calculated. Also the financial analysis for investments and energy costs were carried out. This analysis has been done in according to SPBT and NPV method for different levels of building use.

  13. Optimizing Sustainable Geothermal Heat Extraction

    NASA Astrophysics Data System (ADS)

    Patel, Iti; Bielicki, Jeffrey; Buscheck, Thomas

    2016-04-01

    Geothermal heat, though renewable, can be depleted over time if the rate of heat extraction exceeds the natural rate of renewal. As such, the sustainability of a geothermal resource is typically viewed as preserving the energy of the reservoir by weighing heat extraction against renewability. But heat that is extracted from a geothermal reservoir is used to provide a service to society and an economic gain to the provider of that service. For heat extraction used for market commodities, sustainability entails balancing the rate at which the reservoir temperature renews with the rate at which heat is extracted and converted into economic profit. We present a model for managing geothermal resources that combines simulations of geothermal reservoir performance with natural resource economics in order to develop optimal heat mining strategies. Similar optimal control approaches have been developed for managing other renewable resources, like fisheries and forests. We used the Non-isothermal Unsaturated-saturated Flow and Transport (NUFT) model to simulate the performance of a sedimentary geothermal reservoir under a variety of geologic and operational situations. The results of NUFT are integrated into the optimization model to determine the extraction path over time that maximizes the net present profit given the performance of the geothermal resource. Results suggest that the discount rate that is used to calculate the net present value of economic gain is a major determinant of the optimal extraction path, particularly for shallower and cooler reservoirs, where the regeneration of energy due to the natural geothermal heat flux is a smaller percentage of the amount of energy that is extracted from the reservoir.

  14. Cabauw experimental results from the Project for Intercomparison of Land-Surface Parameterization Schemes

    USGS Publications Warehouse

    Chen, T.H.; Henderson-Sellers, A.; Milly, P.C.D.; Pitman, A.J.; Beljaars, A.C.M.; Polcher, J.; Abramopoulos, F.; Boone, A.; Chang, S.; Chen, F.; Dai, Y.; Desborough, C.E.; Dickinson, R.E.; Dumenil, L.; Ek, M.; Garratt, J.R.; Gedney, N.; Gusev, Y.M.; Kim, J.; Koster, R.; Kowalczyk, E.A.; Laval, K.; Lean, J.; Lettenmaier, D.; Liang, X.; Mahfouf, Jean-Francois; Mengelkamp, H.-T.; Mitchell, Ken; Nasonova, O.N.; Noilhan, J.; Robock, A.; Rosenzweig, C.; Schaake, J.; Schlosser, C.A.; Schulz, J.-P.; Shao, Y.; Shmakin, A.B.; Verseghy, D.L.; Wetzel, P.; Wood, E.F.; Xue, Y.; Yang, Z.-L.; Zeng, Q.

    1997-01-01

    In the Project for Intercomparison of Land-Surface Parameterization Schemes phase 2a experiment, meteorological data for the year 1987 from Cabauw, the Netherlands, were used as inputs to 23 land-surface flux schemes designed for use in climate and weather models. Schemes were evaluated by comparing their outputs with long-term measurements of surface sensible heat fluxes into the atmosphere and the ground, and of upward longwave radiation and total net radiative fluxes, and also comparing them with latent heat fluxes derived from a surface energy balance. Tuning of schemes by use of the observed flux data was not permitted. On an annual basis, the predicted surface radiative temperature exhibits a range of 2 K across schemes, consistent with the range of about 10 W m-2 in predicted surface net radiation. Most modeled values of monthly net radiation differ from the observations by less than the estimated maximum monthly observational error (±10 W m-2). However, modeled radiative surface temperature appears to have a systematic positive bias in most schemes; this might be explained by an error in assumed emissivity and by models' neglect of canopy thermal heterogeneity. Annual means of sensible and latent heat fluxes, into which net radiation is partitioned, have ranges across schemes of 30 W m-2 and 25 W m-2, respectively. Annual totals of evapotranspiration and runoff, into which the precipitation is partitioned, both have ranges of 315 mm. These ranges in annual heat and water fluxes were approximately halved upon exclusion of the three schemes that have no stomatal resistance under non-water-stressed conditions. Many schemes tend to underestimate latent heat flux and overestimate sensible heat flux in summer, with a reverse tendency in winter. For six schemes, root-mean-square deviations of predictions from monthly observations are less than the estimated upper bounds on observation errors (5 W m-2 for sensible heat flux and 10 W m-2 for latent heat flux). Actual runoff at the site is believed to be dominated by vertical drainage to groundwater, but several schemes produced significant amounts of runoff as overland flow or interflow. There is a range across schemes of 184 mm (40% of total pore volume) in the simulated annual mean root-zone soil moisture. Unfortunately, no measurements of soil moisture were available for model evaluation. A theoretical analysis suggested that differences in boundary conditions used in various schemes are not sufficient to explain the large variance in soil moisture. However, many of the extreme values of soil moisture could be explained in terms of the particulars of experimental setup or excessive evapotranspiration.

  15. Cabauw Experimental Results from the Project for Intercomparison of Land-Surface Parameterization Schemes.

    NASA Astrophysics Data System (ADS)

    Chen, T. H.; Henderson-Sellers, A.; Milly, P. C. D.; Pitman, A. J.; Beljaars, A. C. M.; Polcher, J.; Abramopoulos, F.; Boone, A.; Chang, S.; Chen, F.; Dai, Y.; Desborough, C. E.; Dickinson, R. E.; Dümenil, L.; Ek, M.; Garratt, J. R.; Gedney, N.; Gusev, Y. M.;  Kim, J.;  Koster, R.;  Kowalczyk, E. A.;  Laval, K.;  Lean, J.;  Lettenmaier, D.;  Liang, X.;  Mahfouf, J.-F.;  Mengelkamp, H.-T.;  Mitchell, K.;  Nasonova, O. N.;  Noilhan, J.;  Robock, A.;  Rosenzweig, C.;  Schaake, J.;  Schlosser, C. A.;  Schulz, J.-P.;  Shao, Y.;  Shmakin, A. B.;  Verseghy, D. L.;  Wetzel, P.;  Wood, E. F.;  Xue, Y.;  Yang, Z.-L.;  Zeng, Q.

    1997-06-01

    In the Project for Intercomparison of Land-Surface Parameterization Schemes phase 2a experiment, meteorological data for the year 1987 from Cabauw, the Netherlands, were used as inputs to 23 land-surface flux schemes designed for use in climate and weather models. Schemes were evaluated by comparing their outputs with long-term measurements of surface sensible heat fluxes into the atmosphere and the ground, and of upward longwave radiation and total net radiative fluxes, and also comparing them with latent heat fluxes derived from a surface energy balance. Tuning of schemes by use of the observed flux data was not permitted. On an annual basis, the predicted surface radiative temperature exhibits a range of 2 K across schemes, consistent with the range of about 10 W m2 in predicted surface net radiation. Most modeled values of monthly net radiation differ from the observations by less than the estimated maximum monthly observational error (±10 W m2). However, modeled radiative surface temperature appears to have a systematic positive bias in most schemes; this might be explained by an error in assumed emissivity and by models' neglect of canopy thermal heterogeneity. Annual means of sensible and latent heat fluxes, into which net radiation is partitioned, have ranges across schemes of30 W m2 and 25 W m2, respectively. Annual totals of evapotranspiration and runoff, into which the precipitation is partitioned, both have ranges of 315 mm. These ranges in annual heat and water fluxes were approximately halved upon exclusion of the three schemes that have no stomatal resistance under non-water-stressed conditions. Many schemes tend to underestimate latent heat flux and overestimate sensible heat flux in summer, with a reverse tendency in winter. For six schemes, root-mean-square deviations of predictions from monthly observations are less than the estimated upper bounds on observation errors (5 W m2 for sensible heat flux and 10 W m2 for latent heat flux). Actual runoff at the site is believed to be dominated by vertical drainage to groundwater, but several schemes produced significant amounts of runoff as overland flow or interflow. There is a range across schemes of 184 mm (40% of total pore volume) in the simulated annual mean root-zone soil moisture. Unfortunately, no measurements of soil moisture were available for model evaluation. A theoretical analysis suggested that differences in boundary conditions used in various schemes are not sufficient to explain the large variance in soil moisture. However, many of the extreme values of soil moisture could be explained in terms of the particulars of experimental setup or excessive evapotranspiration.

  16. Heat transfer enhancement of flow insulator by combined stainless steel fibrous and wire net porous materials

    NASA Astrophysics Data System (ADS)

    Khantikomol, P.; Polsongkram, M.; Apisitpinyo, W.; Poowadin, T.

    2018-01-01

    The present research article aims to propose the heat transfer enhancement of the flow insulator using combined fibrous and wire net stainless steel porous material. The stainless fibrous plate with porosity of 0.9292 was combined to the stainless steel wire net having pore per inch (PPI) of 16 and total thickness of 30 mm. Two models of the arranging porous plates were prepared, which were model BA and model AB. Each porous plate segment had the same thickness. The examined porous plate model have porosities of 0.8452. The porous plate was placed normal to the flow direction. The air was used as working fluid heated by 5 kW electric heater, which was controlled by the automatic temperature control. Type-K thermocouples were employed to measure the air temperatures. The temperature at front of the porous plate was varied to be 350, 450, and 550°C. The air flow rate was varied in the range of 4-12 m3/hr. The experimental result showed that the temperature drop across the porous plate and the thermal efficiency increase with the inlet temperature. The air velocity slightly affects the temperature profile inside the test section at the upstream side of the porous plate but greatly affects temperature inside the porous plate. In consideration of the arranging porous plate, placing of the stainless steel wire net at the upstream side and placing the stainless steel fibrous at downstream side (model BA) results in the highest temperature drop and the highest thermal efficiency. At Re 733 and inlet temperature 550°C for model BA at 30 mm thickness, the thermal efficiency was 50%. It was shown that the combined stainless steel fibrous and stainless steel wire net porous material could be a good flow insulator.

  17. Village energy survey reveals missing rural raw coal in northern China: Significance in science and policy.

    PubMed

    Zhi, Guorui; Zhang, Yayun; Sun, Jianzhong; Cheng, Miaomiao; Dang, Hongyan; Liu, Shijie; Yang, Junchao; Zhang, Yuzhe; Xue, Zhigang; Li, Shuyuan; Meng, Fan

    2017-04-01

    Burning coal for winter heating has been considered a major contributor to northern China's winter haze, with the district heating boilers holding the balance. However a decade of intensive efforts on district heating boilers brought few improvements to northern China's winter air quality, arousing a speculation that the household heating stoves mainly in rural area rather than the district heating boilers mainly in urban area dominate coal emissions in winter. This implies an extreme underestimation of rural household coal consumption by the China Energy Statistical Yearbooks (CESYs), although direct evidence supporting this speculation is lacking. A village energy survey campaign was launched to gather the firsthand information on household coal consumption in the rural areas of two cities, Baoding (in Hebei province) and Beijing (the capital of China). The survey data show that the rural raw coal consumption in Baoding (5.04 × 10 3  kt) was approximately 6.5 times the value listed in the official CESY 2013 and exceeded the rural total of whole Hebei Province (4668 kt), revealing a huge amount of raw coal missing from the current statistical system. More importantly, rural emissions of particulate matter (PM) and SO 2 from raw coal, which had never been included in widely distributing environmental statistical reports, were found higher than those from industrial and urban household sectors in the two cities in 2013, which highlights the importance of rural coal burning in creating northern China's heavy haze and helps to explain why a number of modeling predictions on ambient pollutant concentrations based on normal emission inventories were more bias-prone in winter season than in other seasons. We therefore recommend placing greater emphasis on the "missing" rural raw coal to help China in its long-term ambition to achieve clean air in the context of rapid economic development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Projected Impact of Climate Change on the Energy Budget of the Arctic Ocean by a Global Climate Model

    NASA Technical Reports Server (NTRS)

    Miller, James R.; Russell, Gary L.; Hansen, James E. (Technical Monitor)

    2001-01-01

    The annual energy budget of the Arctic Ocean is characterized by a net heat loss at the air-sea interface that is balanced by oceanic heat transport into the Arctic. The energy loss at the air-sea interface is due to the combined effects of radiative, sensible, and latent heat fluxes. The inflow of heat by the ocean can be divided into two components: the transport of water masses of different temperatures between the Arctic and the Atlantic and Pacific Oceans and the export of sea ice, primarily through Fram Strait. Two 150-year simulations (1950-2099) of a global climate model are used to examine how this balance might change if atmospheric greenhouse gases (GHGs) increase. One is a control simulation for the present climate with constant 1950 atmospheric composition, and the other is a transient experiment with observed GHGs from 1950 to 1990 and 0.5% annual compounded increases of CO2 after 1990. For the present climate the model agrees well with observations of radiative fluxes at the top of the atmosphere, atmospheric advective energy transport into the Arctic, and surface air temperature. It also simulates the seasonal cycle and summer increase of cloud cover and the seasonal cycle of sea-ice cover. In addition, the changes in high-latitude surface air temperature and sea-ice cover in the GHG experiment are consistent with observed changes during the last 40 and 20 years, respectively. Relative to the control, the last 50-year period of the GHG experiment indicates that even though the net annual incident solar radiation at the surface decreases by 4.6 W(per square meters) (because of greater cloud cover and increased cloud optical depth), the absorbed solar radiation increases by 2.8 W(per square meters) (because of less sea ice). Increased cloud cover and warmer air also cause increased downward thermal radiation at the surface so that the net radiation into the ocean increases by 5.0 Wm-2. The annual increase in radiation into the ocean, however, is compensated by larger increases in sensible and latent heat fluxes out of the ocean. Although the net energy loss from the ocean surface increases by 0.8 W (per square meters), this is less than the interannual variability, and the increase may not indicate a long-term trend. The seasonal cycle of heat fluxes is significantly enhanced. The downward surface heat flux increases in summer (maximum 2 of 19 W per square meters or 23% in June) while the upward heat flux increases in winter (maximum of 16 W per square meters or 28% in November). The increased downward flux in summer is due to a combination of increases in absorbed solar and thermal radiation and smaller losses of sensible and latent heat. The increased heat loss in winter is due to increased sensible and latent heat fluxes, which in turn are due to reduced sea-ice cover. On the other hand, the seasonal cycle of surface air temperature is damped, as there is a large increase in winter temperature but little change in summer.

  19. Erythrocyte-derived optical nano-vesicles as theranostic agents

    NASA Astrophysics Data System (ADS)

    Mac, Jenny T.; Nunez, Vicente; Bahmani, Baharak; Guerrero, Yadir; Tang, Jack; Vullev, Valentine I.; Anvari, Bahman

    2015-07-01

    We have engineered nano-vesicles, derived from erythrocytes, which can be doped with various near infrared (NIR) organic chromophores, including the FDA-approved indocyanine green (ICG). We refer to these vesicles as NIR erythrocyte-mimicking transducers (NETS) since in response to NIR photo-excitation they can generate heat or emit fluorescent light. Using biochemical methods based on reduction amination, we have functionalized the surface of NET with antibodies to target specific biomolecules. We present results that demonstrate the effectiveness of NETs in targeted imaging of cancer cells that over-express the human epidermal growth factor receptor-2 (HER2).

  20. Global energy transports and the influence of clouds on transport requirements - A satellite analysis

    NASA Technical Reports Server (NTRS)

    Sohn, Byung-Ju; Smith, Eric A.

    1992-01-01

    This report investigates the impact of differential net radiative heating on 2D energy transports within the atmosphere ocean system and the role of clouds on this process. The 2D mean energy transports, in answer to zonal and meridional gradients in the net radiation field, show an east-west coupled dipole structure in which the Pacific acts as the major energy source and North Africa as the major energy sink. It is demonstrated that the dipole is embedded in the secondary energy transports arising mainly from the differential heating between land and oceans in the tropics in which the tropical east-west (zonal) transports are up to 30 percent of the tropical north-south (meridional) transports.

  1. Basic performance of a multilayer insulation system containing 20 to 160 layers. [thermal effectiveness of aluminized Mylar-silk net system

    NASA Technical Reports Server (NTRS)

    Stochl, R. J.

    1974-01-01

    An experimental investigation was conducted to determine the thermal effectiveness of an aluminized Mylar-silk net insulation system containing up to 160 layers. The experimentally measured heat flux was compared with results predicted by using (1) a previously developed semi-empirical equation and (2) an effective-thermal-conductivity value. All tests were conducted at a nominal hot-boundary temperature of 294 K (530 R) with liquid hydrogen as the heat sink. The experimental results show that the insulation performed as expected and that both the semi-empirical equation and effective thermal conductivity of a small number of layers were adequate in predicting the thermal performance of a large number of layers of insulation.

  2. Medicaid and CHIP Provide Coverage to More than Half of All Children in D.C. Policy Snapshot

    ERIC Educational Resources Information Center

    DC Action for Children, 2011

    2011-01-01

    Medicaid and CHIP are crucial parts of the social safety net, providing health insurance coverage to more than half of all children ages 0-21 in D.C. and a third of children nationally. Without these two programs, more than 97,000 children in the District would have been uninsured in 2010. New research indicates that compared with the uninsured,…

  3. Estimating surface fluxes over middle and upper streams of the Heihe River Basin with ASTER imagery

    NASA Astrophysics Data System (ADS)

    Ma, W.; Ma, Y.; Hu, Z.; Su, B.; Wang, J.; Ishikawa, H.

    2009-06-01

    Surface fluxes are important boundary conditions for climatological modeling and the Asian monsoon system. Recent availability of high-resolution, multi-band imagery from the ASTER (Advanced Space-borne Thermal Emission and Reflection Radiometer) sensor has enabled us to estimate surface fluxes to bridge the gap between local scale flux measurements using micrometeorological instruments and regional scale land-atmosphere exchanges of water and heat fluxes that are fundamental for the understanding of the water cycle in the Asian monsoon system. A Surface Energy Balance System (SEBS) method based on ASTER data and field observations has been proposed and tested for deriving net radiation flux (Rn), soil heat flux (G0), sensible heat flux (H) and latent heat flux (λ E) over heterogeneous land surface in this paper. As a case study, the methodology was applied to the experimental area of the WATER (Watershed Allied Telemetry Experimental Research), located at the mid-to-upstream sections of the Heihe River, northwest China. The ASTER data of 3 May and 4 June in 2008 was used in this paper for the case of mid-to-upstream sections of the Heihe River Basin. To validate the proposed methodology, the ground-measured land surface heat fluxes (net radiation flux (Rn), soil heat flux (G0), sensible heat flux (H) and latent heat flux (λ E)) were compared to the ASTER derived values. The results show that the derived surface variables and land surface heat fluxes in different months over the study area are in good accordance with the land surface status. It is therefore concluded that the proposed methodology is successful for the retrieval of land surface heat fluxes using the ASTER data and filed observation over the study area.

  4. The effect of delivery mechanisms on the uptake of bed net re-impregnation in Kilifi District, Kenya.

    PubMed

    Snow, R W; McCabe, E; Mbogo, C N; Molyneux, C S; Some, E S; Mung'ala, V O; Nevill, C G

    1999-03-01

    The results of recently completed trials in Africa of insecticide-treated bed nets (ITBN) offer new possibilities for malaria control. These experimental trials aimed for high ITBN coverage combined with high re-treatment rates. Whilst necessary to understand protective efficacy, the approaches used to deliver the intervention provide few indications of what coverage of net re-treatment would be under operational conditions. Varied delivery and financing strategies have been proposed for the sustainable delivery of ITBNs and re-treatment programmes. Following the completion of a randomized, controlled trial on the Kenyan coast, a series of suitable delivery strategies were used to continue net re-treatment in the area. The trial adopted a bi-annual, house-to-house re-treatment schedule free of charge using research project staff and resulted in over 95% coverage of nets issued to children. During the year following the trial, sentinel dipping stations were situated throughout the community and household members informed of their position and opening times. This free re-treatment service achieved between 61-67% coverage of nets used by children for three years. In 1997 a social marketing approach, that introduced cost-retrieval, was used to deliver the net re-treatment services. The immediate result of this transition was that significantly fewer of the mothers who had used the previous re-treatment services adopted this revised approach and coverage declined to 7%. The future of new delivery services and their financing are discussed in the context of their likely impact upon previously defined protective efficacy and cost-effectiveness estimates.

  5. Energy fluxes estimation in a juniper tree area of the Donana biological reserve through TSEB method and Landsat-5TM imagery

    USDA-ARS?s Scientific Manuscript database

    Energy fluxes computing (actual evapotranspiration, net radiation, sensible heat and soil heat flux) are essential to improve the knowledge of the hydrological cycle, especially in natural vegetation covers. In this paper we present the first results of the energy fluxes modeling by means of the TSE...

  6. Willingness to Pay for Measures of Managing the Health Effects of Heat Wave in Beijing, China: a Cross-sectional Survey.

    PubMed

    Zhang, Yi; Chen, Chen; Ban, Jie; Zhao, Jin Hui; Xu, Dan Dan; Zhu, Peng Fei; Li, Tian Tian

    2016-09-01

    There are evidences that heat wave events cause deaths and emergency cases. This article used the contingent valuation method to find the willingness to pay for the protective measures and investigated the factors that influence the willingness to pay. A cross-sectional face-to-face household survey was completed by 637 urban long-term residents and 591 rural long-term residents aged 15-79 in Beijing, China. Binary logistic regression was used to identify factors that influenced the payment rate or payment amount for the protective measures, including independent variables for district, gender, age, education, income, air conditioner ownership, heat wave experience, and chronic non-communicable disease. The payment rate was 41.1% for protective measures provided by the government and 39.5% by measures provided by the market. Most of the respondents were willing to pay 40 CNY per capita annually for measures provided by the government or the market. The factors influencing willingness to pay were district, gender, income, air conditioner ownership, heat wave experience, and chronic non-communicable disease.. Protective measures for heat waves need to be provided immediately. More attention should be paid to the situation of vulnerable groups, such as people who live in urban areas, those without air conditioning, and those who have experienced a heat wave in the past. Copyright © 2016 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  7. Process of optimization of district heat production by utilizing waste energy from metallurgical processes

    NASA Astrophysics Data System (ADS)

    Konovšek, Damjan; Fužir, Miran; Slatinek, Matic; Šepul, Tanja; Plesnik, Kristijan; Lečnik, Samo

    2017-07-01

    In a consortium with SIJ (Slovenian Steel Group), Metal Ravne, the local community of Ravne na Koro\\vskem and the public research Institut Jožef Stefan, with its registered office in Slovenia, Petrol Energetika, d.o.o. set up a technical and technological platform of an innovative energy case for a transition of steel industry into circular economy with a complete energy solution called »Utilization of Waste Heat from Metallurgical Processes for District Heating of Ravne na Koro\\vskem. This is the first such project designed for a useful utilization of waste heat in steel industry which uses modern technology and innovative system solutions for an integration of a smart, efficient and sustainable heating and cooling system and which shows a growth potential. This will allow the industry and cities to make energy savings, to improve the quality of air and to increase the benefits for the society we live in. On the basis of circular economy, we designed a target-oriented co-operation of economy, local community and public research institute to produce new business models where end consumers are put into the centre. This innovation opens the door for steel industry and local community to a joint aim that is a transition into efficient low-carbon energy systems which are based on involvement of natural local conditions, renewable energy sources, the use of waste heat and with respect for the principles of sustainable development.

  8. Relationships between radiation, clouds, and convection during DYNAMO

    NASA Astrophysics Data System (ADS)

    Ciesielski, Paul E.; Johnson, Richard H.; Jiang, Xianan; Zhang, Yunyan; Xie, Shaocheng

    2017-03-01

    The relationships between radiation, clouds, and convection on an intraseasonal time scale are examined with data taken during the Dynamics of the Madden-Julian Oscillation (MJO) field campaign. Specifically, column-net, as well as vertical profiles of radiative heating rates, computed over Gan Island in the central Indian Ocean (IO) are used along with an objective analysis of large-scale fields to examine three MJO events that occurred during the 3 month period (October to December 2011) over this region. Longwave (LW) and shortwave radiative heating rates exhibit tilted structures, reflecting radiative effects associated with the prevalence of shallow cumulus during the dry, suppressed MJO phase followed by increasing deep convection leading into the active phase. As the convection builds going into the MJO active phase, there are increasingly top-heavy anomalous radiative heating rates while the column-net radiative cooling rate progressively decreases. Temporal fluctuations in the cloud radiative forcing, being quite sensitive to changes in high cloudiness, are dominated by LW effects with an intraseasonal variation of 0.4-0.6 K/d. While both the water vapor and cloud fields are inextricably linked, it appears that the tilted radiative structures are more related to water vapor effects. The intraseasonal variation of column-net radiative heating enhances the convective signal in the mean by 20% with a minimum in this enhancement 10 days prior to peak MJO rainfall and maximum 7 days after. This suggests that as MJO convective envelope weakens over the central IO, cloud-radiative feedbacks help maintain the mature MJO as it moves eastward.

  9. Relationships between radiation, clouds, and convection during DYNAMO.

    PubMed

    Ciesielski, Paul E; Johnson, Richard H; Jiang, Xianan; Zhang, Yunyan; Xie, Shaocheng

    2017-03-16

    The relationships between radiation, clouds, and convection on an intraseasonal time scale are examined with data taken during the Dynamics of the Madden-Julian Oscillation (MJO) field campaign. Specifically, column-net, as well as vertical profiles of radiative heating rates, computed over Gan Island in the central Indian Ocean (IO) are used along with an objective analysis of large-scale fields to examine three MJO events that occurred during the 3 month period (October to December 2011) over this region. Longwave (LW) and shortwave radiative heating rates exhibit tilted structures, reflecting radiative effects associated with the prevalence of shallow cumulus during the dry, suppressed MJO phase followed by increasing deep convection leading into the active phase. As the convection builds going into the MJO active phase, there are increasingly top-heavy anomalous radiative heating rates while the column-net radiative cooling rate < Q r > progressively decreases. Temporal fluctuations in the cloud radiative forcing, being quite sensitive to changes in high cloudiness, are dominated by LW effects with an intraseasonal variation of ~0.4-0.6 K/d. While both the water vapor and cloud fields are inextricably linked, it appears that the tilted radiative structures are more related to water vapor effects. The intraseasonal variation of column-net radiative heating < Q r > enhances the convective signal in the mean by ~20% with a minimum in this enhancement ~10 days prior to peak MJO rainfall and maximum ~7 days after. This suggests that as MJO convective envelope weakens over the central IO, cloud-radiative feedbacks help maintain the mature MJO as it moves eastward.

  10. Relationships between radiation, clouds, and convection during DYNAMO

    PubMed Central

    Ciesielski, Paul E.; Johnson, Richard H.; Jiang, Xianan; Zhang, Yunyan; Xie, Shaocheng

    2017-01-01

    The relationships between radiation, clouds, and convection on an intraseasonal time scale are examined with data taken during the Dynamics of the Madden-Julian Oscillation (MJO) field campaign. Specifically, column-net, as well as vertical profiles of radiative heating rates, computed over Gan Island in the central Indian Ocean (IO) are used along with an objective analysis of large-scale fields to examine three MJO events that occurred during the 3 month period (October to December 2011) over this region. Longwave (LW) and shortwave radiative heating rates exhibit tilted structures, reflecting radiative effects associated with the prevalence of shallow cumulus during the dry, suppressed MJO phase followed by increasing deep convection leading into the active phase. As the convection builds going into the MJO active phase, there are increasingly top-heavy anomalous radiative heating rates while the column-net radiative cooling rate progressively decreases. Temporal fluctuations in the cloud radiative forcing, being quite sensitive to changes in high cloudiness, are dominated by LW effects with an intraseasonal variation of ~0.4–0.6 K/d. While both the water vapor and cloud fields are inextricably linked, it appears that the tilted radiative structures are more related to water vapor effects. The intraseasonal variation of column-net radiative heating enhances the convective signal in the mean by ~20% with a minimum in this enhancement ~10 days prior to peak MJO rainfall and maximum ~7 days after. This suggests that as MJO convective envelope weakens over the central IO, cloud-radiative feedbacks help maintain the mature MJO as it moves eastward. PMID:29082119

  11. Malaria transmission in Tripura: Disease distribution & determinants.

    PubMed

    Dev, Vas; Adak, Tridibes; Singh, Om P; Nanda, Nutan; Baidya, Bimal K

    2015-12-01

    Malaria is a major public health problem in Tripura and focal disease outbreaks are of frequent occurrence. The state is co-endemic for both Plasmodium falciparum and P. vivax and transmission is perennial and persistent. The present study was aimed to review data on disease distribution to prioritize high-risk districts, and to study seasonal prevalence of disease vectors and their bionomical characteristics to help formulate vector species-specific interventions for malaria control. Data on malaria morbidity in the State were reviewed retrospectively (2008-2012) for understanding disease distribution and transmission dynamics. Cross-sectional mass blood surveys were conducted in malaria endemic villages of South Tripura district to ascertain the prevalence of malaria and proportions of parasite species. Mosquito collections were made in human dwellings of malaria endemic villages aiming at vector incrimination and to study relative abundance, resting and feeding preferences, and their present susceptibility status to DDT. The study showed that malaria was widely prevalent and P. falciparum was the predominant infection (>90%), the remaining were P. vivax cases. The disease distribution, however, was uneven with large concentration of cases in districts of South Tripura and Dhalai coinciding with vast forest cover and tribal populations. Both Anopheles minimus s.s. and An. baimaii were recorded to be prevalent and observed to be highly anthropophagic and susceptible to DDT. Of these, An. minimus was incriminated (sporozoite infection rate 4.92%), and its bionomical characteristics revealed this species to be largely indoor resting and endophagic. For effective control of malaria in the state, it is recommended that diseases surveillance should be robust, and vector control interventions including DDT spray coverage, mass distribution of insecticide-treated nets/ long-lasting insecticidal nets should be intensified prioritizing population groups most at risk to avert impending disease outbreaks and spread of drug-resistant malaria.

  12. Towards a Net Zero Building Cluster Energy Systems Analysis for a Brigade Combat Team Complex

    DTIC Science & Technology

    2010-05-01

    of technologies, like cogeneration or combined heat and power, waste heat recovery, biomass, geother- mal energy, solar heating (and cooling), and...peaks of individual buildings; thus the needed gen- eration and back-up capacity is smaller. To develop the community energy concept, energy models...overall thermal energy system, a hydraulic flow model (Figure 5) should be used to analyze critical capacities and flows in the system. This material is

  13. The Dynamics of Energy and CO2 Transport above a Subtropical Rice Paddy

    NASA Astrophysics Data System (ADS)

    Hsieh, C.; Huang, C.; Cheng, S.

    2013-12-01

    An eddy-covariance system was established to understand the dynamics of turbulent transport of sensible heat, water vapor, and CO2 above a subtropical rice paddy in north Taiwan (24°48'07.958'N, 121°47'58.665'E). The results showed that, during crop season, about 25% of net radiation was used for latent heat flux, 10% for sensible heat flux, and the rest (65%) was absorbed by the water and soil in the rice paddy. However, during fallow period, where there was no rice in the paddy, both water vapor and sensible heat fluxes occupied about 18% of the net radiation. Also, Penman-Monteith equation was found to reproduce the water vapor flux well with surface resistance close to 190 s m-1. We also found that, under small Bowen ratio (< 0.2) conditions, water vapor and CO2 were transported more efficiently than heat. However, when Bowen ration was large (> 0.5), sensible heat was transported about 10% more efficiently than both water vapor and CO2. During crop season the maximum CO2 uptake was about 22 micro mol m-2 s-1. In fallow period, the maximum CO2 emission rate from the soil-water surface was around 5 micro mol m-2 s-1, which was about the same as the growing season.

  14. Metabolic and thermodynamic responses to dehydration-induced reductions in muscle blood flow in exercising humans

    PubMed Central

    González-Alonso, José; Calbet, José A L; Nielsen, Bodil

    1999-01-01

    The present study examined whether reductions in muscle blood flow with exercise-induced dehydration would reduce substrate delivery and metabolite and heat removal to and from active skeletal muscles during prolonged exercise in the heat. A second aim was to examine the effects of dehydration on fuel utilisation across the exercising leg and identify factors related to fatigue. Seven cyclists performed two cycle ergometer exercise trials in the heat (35°C; 61 ± 2% of maximal oxygen consumption rate, VO2,max), separated by 1 week. During the first trial (dehydration, DE), they cycled until volitional exhaustion (135 ± 4 min, mean ±s.e.m.), while developing progressive DE and hyperthermia (3.9 ± 0.3% body weight loss and 39.7 ± 0.2°C oesophageal temperature, Toes). On the second trial (control), they cycled for the same period of time maintaining euhydration by ingesting fluids and stabilising Toes at 38.2 ± 0.1°C. After 20 min of exercise in both trials, leg blood flow (LBF) and leg exchange of lactate, glucose, free fatty acids (FFA) and glycerol were similar. During the 20 to 135 ± 4 min period of exercise, LBF declined significantly in DE but tended to increase in control. Therefore, after 120 and 135 ± 4 min of DE, LBF was 0.6 ± 0.2 and 1.0 ± 0.3 l min−1 lower (P < 0.05), respectively, compared with control. The lower LBF after 2 h in DE did not alter glucose or FFA delivery compared with control. However, DE resulted in lower (P < 0.05) net FFA uptake and higher (P < 0.05) muscle glycogen utilisation (45%), muscle lactate accumulation (4.6-fold) and net lactate release (52%), without altering net glycerol release or net glucose uptake. In both trials, the mean convective heat transfer from the exercising legs to the body core ranged from 6.3 ± 1.7 to 7.2 ± 1.3 kJ min−1, thereby accounting for 35-40 % of the estimated rate of heat production (∼18 kJ min−1). At exhaustion in DE, blood lactate values were low whereas blood glucose and muscle glycogen levels were still high. Exhaustion coincided with high body temperature (∼40°C). In conclusion, the present results demonstrate that reductions in exercising muscle blood flow with dehydration do not impair either the delivery of glucose and FFA or the removal of lactate during moderately intense prolonged exercise in the heat. However, dehydration during exercise in the heat elevates carbohydrate oxidation and lactate production. A major finding is that more than one-half of the metabolic heat liberated in the contracting leg muscles is dissipated directly to the surrounding environment. The present results indicate that hyperthermia, rather than altered metabolism, is the main factor underlying the early fatigue with dehydration during prolonged exercise in the heat. PMID:10523424

  15. The costs and effects of a nationwide insecticide-treated net programme: the case of Malawi

    PubMed Central

    Stevens, Warren; Wiseman, Virginia; Ortiz, Juan; Chavasse, Desmond

    2005-01-01

    Background Insecticide-treated nets (ITNs) are a proven intervention to reduce the burden of malaria, yet there remains a debate as to the best method of ensuring they are universally utilized. This study is a cost-effectiveness analysis of an intervention in Malawi that started in 1998, in Blantyre district, before expanding nationwide. Over the 5-year period, 1.5 million ITNs were sold. Methods The costs were calculated retrospectively through analysis of expenditure data. Costs and effects were measured as cost per treated-net year (cost/TNY) and cost per net distributed. Results The mean cost/TNY was calculated at $4.41, and the mean cost/ITN distributed at $2.63. It also shows evidence of economies of scale, with the cost/TNY falling from $7.69 in year one (72,196 ITN) to $3.44 in year five (720,577 ITN). Cost/ITN distributed dropped from $5.04 to $1.92. Conclusion Combining targeting and social marketing has the potential of being both cost-effective and capable of achieving high levels of coverage, and it is possible that increasing returns to scale can be achieved. PMID:15885143

  16. Korean 4- to 11-Year-Old Student Conceptions of Heat and Temperature

    ERIC Educational Resources Information Center

    Paik, Seoung-Hey; Cho, Boo-Kyung; Go, Young-Mi

    2007-01-01

    The aim of the present study is to shed light on the conceptions that young students have of heat and temperature, concepts that are both important in school science curricula and closely related to daily life. The subjects of the study were students from a rural district in South Korea and they ranged in age from 4 to 11 years. Interviews were…

  17. Net change in carbon emissions with increased wood energy use in the United States

    Treesearch

    Prakash Nepal; David N. Wear; Kenneth E. Skog

    2014-01-01

    Use of wood biomass for energy results in carbon (C) emissions at the time of burning and alters C stocks on the land because of harvest, regrowth, and changes in land use or management. This study evaluates the potential effects of expanded woody biomass energy use (for heat and power) on net C emissions over time. A scenario with increased wood energy use is compared...

  18. Moisture sorption isotherms and thermodynamic properties of bovine leather

    NASA Astrophysics Data System (ADS)

    Fakhfakh, Rihab; Mihoubi, Daoued; Kechaou, Nabil

    2018-04-01

    This study was aimed at the determination of bovine leather moisture sorption characteristics using a static gravimetric method at 30, 40, 50, 60 and 70 °C. The curves exhibit type II behaviour according to the BET classification. The sorption isotherms fitting by seven equations shows that GAB model is able to reproduce the equilibrium moisture content evolution with water activity for moisture range varying from 0.02 to 0.83 kg/kg d.b (0.9898 < R2 < 0.999). The sorption isotherms exhibit hysteresis effect. Additionally, sorption isotherms data were used to determine the thermodynamic properties such as isosteric heat of sorption, sorption entropy, spreading pressure, net integral enthalpy and entropy. Net isosteric heat of sorption and differential entropy were evaluated through direct use of moisture isotherms by applying the Clausius-Clapeyron equation and used to investigate the enthalpy-entropy compensation theory. Both sorption enthalpy and entropy for desorption increase to a maximum with increasing moisture content, and then decrease sharply with rising moisture content. Adsorption enthalpy decreases with increasing moisture content. Whereas, adsorption entropy increases smoothly with increasing moisture content to a maximum of 6.29 J/K.mol. Spreading pressure increases with rising water activity. The net integral enthalpy seemed to decrease and then increase to become asymptotic. The net integral entropy decreased with moisture content increase.

  19. Recent trends (2003-2013) of land surface heat fluxes on the southern side of the central Himalayas, Nepal

    NASA Astrophysics Data System (ADS)

    Amatya, Pukar Man; Ma, Yaoming; Han, Cunbo; Wang, Binbin; Devkota, Lochan Prasad

    2015-12-01

    Novice efforts have been made in order to study the regional distribution of land surface heat fluxes on the southern side of the central Himalayas utilizing high-resolution remotely sensed products, but these have been on instantaneous scale. In this study the Surface Energy Balance System model is used to obtain annual averaged maps of the land surface heat fluxes for 11 years (2003-2013) and study their annual trends on the central Himalayan region. The maps were derived at 5 km resolution using monthly input products ranging from satellite derived to Global Land Data Assimilation System meteorological data. It was found that the net radiation flux is increasing as a result of decreasing precipitation (drier environment). The sensible heat flux did not change much except for the northwestern High Himalaya and High Mountains. In northwestern High Himalaya sensible heat flux is decreasing because of decrease in wind speed, ground-air temperature difference, and increase in winter precipitation, whereas in High Mountains it is increasing due to increase in ground-air temperature difference and high rate of deforestation. The latent heat flux has an overall increasing trend with increase more pronounced in the lower regions compared to high elevated regions. It has been reported that precipitation is decreasing with altitude in this region. Therefore, the increasing trend in latent heat flux can be attributed to increase in net radiation flux under persistent forest cover and irrigation land used for agriculture.

  20. Urban Renewable Building And Neighborhood Optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    URBANopt is a user interface for creating and running district and city scale building energy simulations. The framework is built around the OpenStudio Urban Measures which are part of the OpenStudio project. Building footprints, building height, building type, and other data can be imported from public records or other sources. Footprints and locations for new buildings and district systems can also be specified. OpenStudio Measures are used to create starting point energy models and to model energy design features and efficiency measures for each building. URBANopt allows a user to pose several scenarios such as “what if 30% of themore » commercial retail buildings added roof top solar” or “what if all elementary schools converted to ground source heat pumps” and then visualize the impacts at a district or city scale. URBANopt is capable of modeling existing buildings, new construction, and district energy systems. URBANopt can be used to explore options for achieving Zero Energy across a collection of buildings (e.g., Zero Energy Districts).« less

  1. Recov'Heat: An estimation tool of urban waste heat recovery potential in sustainable cities

    NASA Astrophysics Data System (ADS)

    Goumba, Alain; Chiche, Samuel; Guo, Xiaofeng; Colombert, Morgane; Bonneau, Patricia

    2017-02-01

    Waste heat recovery is considered as an efficient way to increase carbon-free green energy utilization and to reduce greenhouse gas emission. Especially in urban area, several sources such as sewage water, industrial process, waste incinerator plants, etc., are still rarely explored. Their integration into a district heating system providing heating and/or domestic hot water could be beneficial for both energy companies and local governments. EFFICACITY, a French research institute focused on urban energy transition, has developed an estimation tool for different waste heat sources potentially explored in a sustainable city. This article presents the development method of such a decision making tool which, by giving both energetic and economic analysis, helps local communities and energy service companies to make preliminary studies in heat recovery projects.

  2. Assessment of coverage of preventive treatment and insecticide-treated mosquito nets in pregnant women attending antenatal care services in 11 districts in Mozambique in 2011: the critical role of supply chain.

    PubMed

    Salomão, Cristolde; Sacarlal, Jahit; Gudo, Eduardo Samo

    2017-05-25

    Malaria during pregnancy is associated with poor maternal and pregnancy outcome and the World Health Organization recommends the administration of intermittent preventive treatment in pregnancy (IPTp) with sulfadoxine-pyrimethamine (SP) and distribution of insecticide-treated mosquito nets (ITNs) to all pregnant women attending antenatal care (ANC) services. This study was conducted with the aim to assess the uptake of IPTp and ITNs in pregnant women attending ANC services and correlate with ANC attendance and frequency of stock-outs in 22 health facilities Mozambique. A cross-sectional study was conducted between July and December 2011 in 22 health units in 11 districts situated in 11 provinces in Mozambique. Two health facilities were selected per district (one urban and one rural). Data were collected by reviewing logbooks of antenatal consultations as well as from monthly district reports. During the period under investigation, a total of 23,524 pregnant women attended their 1st antenatal care visits, of which 12,775 (54.3%) and 7581 (32.2%) received one and two doses of IPTp, respectively. In regard to ITNs, a total of 16,436 (69.9%) pregnant women received ITNs. Uptake of IPTp and ITNs by pregnant women at ANC services was higher in southern Mozambique and lower in districts situated in the northern part of the country. Stock-outs of SP and ITNs were reported in 50.0% (11/22) and 54.5% (12/22) of the health facilities, respectively. Coverage of IPTp and ITN in health facilities with stock-outs of SP and ITNs was much lower as compared to health facilities with no stock-outs. Altogether, data from this study shows that coverage of the 2nd dose of IPTp, as well as ITNs, was low in pregnant women attending ANC services in Mozambique. In addition, this data also shows that stock-outs of SP and ITNs were frequent and led to lower coverage of IPTp and ITN, representing a serious barrier for the accomplishment of targets. In conclusion, this study recommends that efforts should be made to improve the supply chains of SP and ITNs.

  3. Sleeping arrangements and mass distribution of bed nets in six districts in central and northern Mozambique.

    PubMed

    Plucinski, M M; Chicuecue, S; Macete, E; Chambe, G A; Muguande, O; Matsinhe, G; Colborn, J; Yoon, S S; Doyle, T J; Kachur, S P; Aide, P; Alonso, P L; Guinovart, C; Morgan, J

    2015-12-01

    Universal coverage with insecticide-treated bed nets is a cornerstone of modern malaria control. Mozambique has developed a novel bed net allocation strategy, where the number of bed nets allocated per household is calculated on the basis of household composition and assumptions about who sleeps with whom. We set out to evaluate the performance of the novel allocation strategy. A total of 1994 households were visited during household surveys following two universal coverage bed net distribution campaigns in Sofala and Nampula provinces in 2010-2013. Each sleeping space was observed for the presence of a bed net, and the sleeping patterns for each household were recorded. The observed coverage and efficiency were compared to a simulated coverage and efficiency had conventional allocation strategies been used. A composite indicator, the product of coverage and efficiency, was calculated. Observed sleeping patterns were compared with the sleeping pattern assumptions. In households reached by the campaign, 93% (95% CI: 93-94%) of sleeping spaces in Sofala and 84% (82-86%) in Nampula were covered by campaign bed nets. The achieved efficiency was high, with 92% (91-93%) of distributed bed nets in Sofala and 93% (91-95%) in Nampula covering a sleeping space. Using the composite indicator, the novel allocation strategy outperformed all conventional strategies in Sofala and was tied for best in Nampula. The sleeping pattern assumptions were completely satisfied in 66% of households in Sofala and 56% of households in Nampula. The most common violation of the sleeping pattern assumptions was that male children 3-10 years of age tended not to share sleeping spaces with female children 3-10 or 10-16 years of age. The sleeping pattern assumptions underlying the novel bed net allocation strategy are generally valid, and net allocation using these assumptions can achieve high coverage and compare favourably with conventional allocation strategies. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  4. Energy Sources and Systems Analysis: 40 South Lincoln Redevelopment District (Short Report)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-08-01

    This report presents the a brief overview of the results of a case study to analyze district energy systems for their potential use in a project that involves redeveloping 270 units of existing public housing, along with other nearby sites. When complete, the redevelopment project will encompass more than 900 mixed-income residential units, commercial and retail properties, and open space. The analysis estimated the hourly heating, cooling, domestic hot water, and electric loads required by the community; investigated potential district system technologies to meet those needs; and researched available fuel sources to power such systems. A full report of thismore » case study is also available.« less

  5. Theoretical Evaluation of the Maximum Work of Free-Piston Engine Generators

    NASA Astrophysics Data System (ADS)

    Kojima, Shinji

    2017-01-01

    Utilizing the adjoint equations that originate from the calculus of variations, we have calculated the maximum thermal efficiency that is theoretically attainable by free-piston engine generators considering the work loss due to friction and Joule heat. Based on the adjoint equations with seven dimensionless parameters, the trajectory of the piston, the histories of the electric current, the work done, and the two kinds of losses have been derived in analytic forms. Using these we have conducted parametric studies for the optimized Otto and Brayton cycles. The smallness of the pressure ratio of the Brayton cycle makes the net work done negative even when the duration of heat addition is optimized to give the maximum amount of heat addition. For the Otto cycle, the net work done is positive, and both types of losses relative to the gross work done become smaller with the larger compression ratio. Another remarkable feature of the optimized Brayton cycle is that the piston trajectory of the heat addition/disposal process is expressed by the same equation as that of an adiabatic process. The maximum thermal efficiency of any combination of isochoric and isobaric heat addition/disposal processes, such as the Sabathe cycle, may be deduced by applying the methods described here.

  6. Community-directed interventions for priority health problems in Africa: results of a multicountry study.

    PubMed

    2010-07-01

    To determine the extent to which the community-directed approach used in onchocerciasis control in Africa could effectively and efficiently provide integrated delivery of other health interventions. A three-year experimental study was undertaken in 35 health districts from 2005 to 2007 in seven research sites in Cameroon, Nigeria and Uganda. Four trial districts and one comparison district were randomly selected in each site. All districts had established ivermectin treatment programmes, and in the trial districts four other established interventions - vitamin A supplementation, use of insecticide-treated nets, home management of malaria and short-course, directly-observed treatment for tuberculosis patients - were progressively incorporated into a community-directed intervention (CDI) process. At the end of each of the three study years, we performed quantitative evaluations of intervention coverage and provider costs, as well as qualitative assessments of the CDI process. With the CDI strategy, significantly higher coverage was achieved than with other delivery approaches for all interventions except for short-course, directly-observed treatment. The coverage of malaria interventions more than doubled. The district-level costs of delivering all five interventions were lower in the CDI districts, but no cost difference was found at the first-line health facility level. Process evaluation showed that: (i) participatory processes were important; (ii) recurrent problems with the supply of intervention materials were a major constraint to implementation; (iii) the communities and community implementers were deeply committed to the CDI process; (iv) community implementers were more motivated by intangible incentives than by external financial incentives. The CDI strategy, which builds upon the core principles of primary health care, is an effective and efficient model for integrated delivery of appropriate health interventions at the community level in Africa.

  7. Community-directed interventions for priority health problems in Africa: results of a multicountry study

    PubMed Central

    2010-01-01

    Abstract Objective To determine the extent to which the community-directed approach used in onchocerciasis control in Africa could effectively and efficiently provide integrated delivery of other health interventions. Methods A three-year experimental study was undertaken in 35 health districts from 2005 to 2007 in seven research sites in Cameroon, Nigeria and Uganda. Four trial districts and one comparison district were randomly selected in each site. All districts had established ivermectin treatment programmes, and in the trial districts four other established interventions – vitamin A supplementation, use of insecticide-treated nets, home management of malaria and short-course, directly-observed treatment for tuberculosis patients – were progressively incorporated into a community-directed intervention (CDI) process. At the end of each of the three study years, we performed quantitative evaluations of intervention coverage and provider costs, as well as qualitative assessments of the CDI process. Findings With the CDI strategy, significantly higher coverage was achieved than with other delivery approaches for all interventions except for short-course, directly-observed treatment. The coverage of malaria interventions more than doubled. The district-level costs of delivering all five interventions were lower in the CDI districts, but no cost difference was found at the first-line health facility level. Process evaluation showed that: (i) participatory processes were important; (ii) recurrent problems with the supply of intervention materials were a major constraint to implementation; (iii) the communities and community implementers were deeply committed to the CDI process; (iv) community implementers were more motivated by intangible incentives than by external financial incentives. Conclusion The CDI strategy, which builds upon the core principles of primary health care, is an effective and efficient model for integrated delivery of appropriate health interventions at the community level in Africa. PMID:20616970

  8. Work production of quantum rotor engines

    NASA Astrophysics Data System (ADS)

    Seah, Stella; Nimmrichter, Stefan; Scarani, Valerio

    2018-04-01

    We study the mechanical performance of quantum rotor heat engines in terms of common notions of work using two prototypical models: a mill driven by the heat flow from a hot to a cold mode, and a piston driven by the alternate heating and cooling of a single working mode. We evaluate the extractable work in terms of ergotropy, the kinetic energy associated to net directed rotation, as well as the intrinsic work based on the exerted torque under autonomous operation, and we compare them to the energy output for the case of an external dissipative load and for externally driven engine cycles. Our results connect work definitions from both physical and information-theoretical perspectives. In particular, we find that apart from signatures of angular momentum quantization, the ergotropy is consistent with the intuitive notion of work in the form of net directed motion. It also agrees with the energy output to an external load or agent under optimal conditions. This sets forth a consistent thermodynamical description of rotating quantum motors, flywheels, and clocks.

  9. Spatialization of instantaneous and daily average net radiation and soil heat flux in the territory of Itaparica, Northeast Brazil

    NASA Astrophysics Data System (ADS)

    Lopes, Helio L.; Silva, Bernardo B.; Teixeira, Antônio H. C.; Accioly, Luciano J. O.

    2012-09-01

    This work has as aim to quantify the energy changes between atmosphere and surface by modeling both net radiation and soil heat flux related to land use and cover. The methodology took into account modeling and mapping of physical and biophysical parameters using MODIS images and SEBAL algorithm in an area of native vegetation and irrigated crops. The results showed that there are variations in the values of the estimated parameters for different land cover types and mainly in caatinga cover. The dense caatinga presents mean values of soil heat flux (Go) of 124.9 Wm-2 while sparse caatinga with incidence of erosion, present average value of 132.6 Wm-2. For irrigated plots cultivated with banana, coconut, and papaya the mean Go values were 103.8, 98.6, 113.9 Wm-2, respectively. With regard to the instantaneous net radiation (Rn), dense caatinga presented mean value of 626.1 Wm-2, while sparse caatinga a mean value of 575.2 Wm-2. Irrigated areas cultivated with banana, coconut, and papaya presented Rn of 658.1, 647.4 and 617.9 W m-2 respectively. Applying daily mean net radiation (RnDAve) it was found that dense caatinga had a mean value of 417.1 W m-2, while sparse caatinga had a mean value of 379.9 W m-2. For the irrigated crops of banana, coconut and papaya the RnDAve values were 430.9, 431.3 and 411.6 W m-2, respectively. Sinusoidal model can be applied to determine the maximum and RnDAve considering the diverse classes of LULC; however, there is a need to compare the results with field data for validation of this model.

  10. Comparison of 37 months global net radiation flux derived from PICARD-BOS over the same period observations of CERES and ARGO

    NASA Astrophysics Data System (ADS)

    Zhu, Ping; Wild, Martin

    2016-04-01

    The absolute level of the global net radiation flux (NRF) is fixed at the level of [0.5-1.0] Wm-2 based on the ocean heat content measurements [1]. The space derived global NRF is at the same order of magnitude than the ocean [2]. Considering the atmosphere has a negligible effects on the global NRF determination, the surface global NRF is consistent with the values determined from space [3]. Instead of studying the absolute level of the global NRF, we focus on the interannual variation of global net radiation flux, which were derived from the PICARD-BOS experiment and its comparison with values over the same period but obtained from the NASA-CERES system and inferred from the ocean heat content survey by ARGO network. [1] Allan, Richard P., Chunlei Liu, Norman G. Loeb, Matthew D. Palmer, Malcolm Roberts, Doug Smith, and Pier-Luigi Vidale (2014), Changes in global net radiative imbalance 1985-2012, Geophysical Research Letters, 41 (no.15), 5588-5597. [2] Loeb, Norman G., John M. Lyman, Gregory C. Johnson, Richard P. Allan, David R. Doelling, Takmeng Wong, Brian J. Soden, and Graeme L. Stephens (2012), Observed changes in top-of-the-atmosphere radiation and upper-ocean heating consistent within uncertainty, Nature Geoscience, 5 (no.2), 110-113. [3] Wild, Martin, Doris Folini, Maria Z. Hakuba, Christoph Schar, Sonia I. Seneviratne, Seiji Kato, David Rutan, Christof Ammann, Eric F. Wood, and Gert Konig-Langlo (2015), the energy balance over land and oceans: an assessment based on direct observations and CMIP5 climate models, Climate Dynamics, 44 (no.11-12), 3393-3429.

  11. The Vorticity Budgets of North Atlantic Winter Marine Extratropical Cyclones Development

    NASA Astrophysics Data System (ADS)

    Azad, R.; Sorteberg, A.

    2012-12-01

    A partitioned form of the Zwack-Okossi (Z-O) tendency equation is employed to examine the composite role of dynamic and thermodynamic forcing mechanisms to the development of North Atlantic winter marine extratropical cyclones. The results provide a further insight into the budgets of near surface cyclonic geostrophic vorticity (CGV) and their evolution during the life cycle of mid-latitude low pressure systems. Of interest are the direct, indirect and net effects of the Z-O forcing mechanisms. The direct effect shows the contribution of each process to the near surface geostrophic vorticity tendency, while the indirect effect implies the contribution from the associated vertical motion and resulting adiabatic cooling or warming. The net effect is the sum of the direct and indirect effects.We found that the vorticity advection term is the largest net contributor to the development of the marine cyclones. The net positive effect of both the temperature advection and latent heating terms is smaller owing to the induced adiabatic cooling which reduces the positive direct contributions. The direct and indirect parts of ageostrophic tendency and friction terms support each other, resulting in significant net contributions at the low center.Comparisons of the composite contributions by the Z-O forcing terms at different pressure levels over the low center indicate that, in agreement with previous studies, the commencement of significant development is accompanied with the upper level cyclonic absolute vorticity advection, upper level warm advection and mid-to low level latent heating. However, during the end of the development, mid-tropospheric net contribution by vorticity advection term and low level warm advection controls the production of CGV. The former is due to both the presence of mid-level cyclonic vorticity advection and induced adiabatic warming over the composite low center.

  12. Crawl space assisted heat pump. [using stored ground heat

    NASA Technical Reports Server (NTRS)

    Ternes, M. P.

    1980-01-01

    A variety of experiments and simulations, currently being designed or underway, to determine the feasibility of conditioning the source air of an air to air heat pump using stored ground heat or cool to produce higher seasonal COP's and net energy savings are discussed. The ground would condition ambient air as it is drawn through the crawl space of a house. Tests designed to evaluate the feasibility of the concept, to determine the amount of heat or cool available from the ground, to study the effect of the system on the heating and cooling loads of the house, to study possible mechanisms which could enhance heat flow through the ground, and to determine if diurnal temperature swings are necessary to achieve successful system performance are described.

  13. Tests of a robust eddy correlation system for sensible heat flux

    NASA Astrophysics Data System (ADS)

    Blanford, J. H.; Gay, L. W.

    1992-03-01

    Sensible heat flux estimates from a simple, one-propeller eddy correlation system (OPEC) were compared with those from a sonic anemometer eddy correlation system (SEC). In accordance with similarity theory, the performance of the OPEC system improved with increasing height of the sensor above the surface. Flux totals from the two systems at sites with adequate fetch were in excellent agreement after frequency response corrections were applied. The propeller system appears suitable for long periods of unattended measurement. The sensible heat flux measurements can be combined with net radiation and soil heat flux measurements to estimate latent heat as a residual in the surface energy balance.

  14. Spectral estimates of net radiation and soil heat flux

    USGS Publications Warehouse

    Daughtry, C.S.T.; Kustas, William P.; Moran, M.S.; Pinter, P. J.; Jackson, R. D.; Brown, P.W.; Nichols, W.D.; Gay, L.W.

    1990-01-01

    Conventional methods of measuring surface energy balance are point measurements and represent only a small area. Remote sensing offers a potential means of measuring outgoing fluxes over large areas at the spatial resolution of the sensor. The objective of this study was to estimate net radiation (Rn) and soil heat flux (G) using remotely sensed multispectral data acquired from an aircraft over large agricultural fields. Ground-based instruments measured Rn and G at nine locations along the flight lines. Incoming fluxes were also measured by ground-based instruments. Outgoing fluxes were estimated using remotely sensed data. Remote Rn, estimated as the algebraic sum of incoming and outgoing fluxes, slightly underestimated Rn measured by the ground-based net radiometers. The mean absolute errors for remote Rn minus measured Rn were less than 7%. Remote G, estimated as a function of a spectral vegetation index and remote Rn, slightly overestimated measured G; however, the mean absolute error for remote G was 13%. Some of the differences between measured and remote values of Rn and G are associated with differences in instrument designs and measurement techniques. The root mean square error for available energy (Rn - G) was 12%. Thus, methods using both ground-based and remotely sensed data can provide reliable estimates of the available energy which can be partitioned into sensible and latent heat under nonadvective conditions. ?? 1990.

  15. Scoping study for compact high-field superconducting net energy tokamaks

    NASA Astrophysics Data System (ADS)

    Mumgaard, R. T.; Greenwald, M.; Freidberg, J. P.; Wolfe, S. M.; Hartwig, Z. S.; Brunner, D.; Sorbom, B. N.; Whyte, D. G.

    2016-10-01

    The continued development and commercialization of high temperature superconductors (HTS) may enable the construction of compact, net-energy tokamaks. HTS, in contrast to present generation low temperature superconductors, offers improved performance in high magnetic fields, higher current density, stronger materials, higher temperature operation, and simplified assembly. Using HTS along with community-consensus confinement physics (H98 =1) may make it possible to achieve net-energy (Q>1) or burning plasma conditions (Q>5) in DIII-D or ASDEX-U sized, conventional aspect ratio tokamaks. It is shown that, by operating at high plasma current and density enabled by the high magnetic field (B>10T), the required triple products may be achieved at plasma volumes under 20m3, major radii under 2m, with external heating powers under 40MW. This is at the scale of existing devices operated by laboratories, universities and companies. The trade-offs in the core heating, divertor heat exhaust, sustainment, stability, and proximity to known plasma physics limits are discussed in the context of the present tokamak experience base and the requirements for future devices. The resulting HTS-based design space is compared and contrasted to previous studies on high-field copper experiments with similar missions. The physics exploration conducted with such HTS devices could decrease the real and perceived risks of ITER exploitation, and aid in quickly developing commercially-applicable tokamak pilot plants and reactors.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuttica, John; Haefke, Cliff

    The Midwest Clean Energy Application Center (CEAC) was one of eight regional centers that promoted and assisted in transforming the market for combined heat and power (CHP), waste heat to power (WHP), and district energy (DE) technologies and concepts throughout the United States between October 1, 2009 and December 31, 2013. The key services the CEACs provided included: Market Opportunity Analyses – Supporting analyses of CHP market opportunities in diverse markets including industrial, federal, institutional, and commercial sectors. Education and Outreach – Providing information on the energy and non-energy benefits and applications of CHP to state and local policy makers,more » regulators, energy end-users, trade associations and others. Information was shared on the Midwest CEAC website: www.midwestcleanergy.org. Technical Assistance – Providing technical assistance to end-users and stakeholders to help them consider CHP, waste heat to power, and/or district energy with CHP in their facility and to help them through the project development process from initial CHP screening to installation. The Midwest CEAC provided services to the Midwest Region that included the states of Illinois, Indiana, Iowa, Kansas, Michigan, Minnesota, Missouri, Nebraska, North Dakota, Ohio, South Dakota, and Wisconsin.« less

  17. Urban climate and energy demand interaction in Northern Eurasia

    NASA Astrophysics Data System (ADS)

    Kasilova, E. V.; Ginzburg, A. S.; Demchenko, P. F.

    2017-11-01

    The regional and urban climate change in Northern Eurasia is one of the main challenges for sustainable development of human habitats situated in boreal and temperate areas. The half of primary energy is spent for space heating even under quite a mild European climate. Implementation of the district heating in urban areas is currently seen as one of the key conditions of sustainable development. The clear understanding of main problems of the urban climateenergy demand interaction is crucial for both small towns and megacities. The specific features of the urban energy systems in Finland, Russia and China under the changing climate conditions were studied. Regional manifestations of the climate change were examined. The climate projections were established for urban regions of the Northern Eurasia. It was shown that the climate warming is likely to continue intensively there. History and actual development trends were discussed for the urban district heating systems in Russia, China and Finland. Common challenges linked with the climate change have been identified for the considered areas. Adaptation possibilities were discussed taking into account climate-energy interactions.

  18. Traditional nets interfere with the uptake of long-lasting insecticidal nets in the Peruvian Amazon: the relevance of net preference for achieving high coverage and use.

    PubMed

    Grietens, Koen Peeters; Muela Ribera, Joan; Soto, Veronica; Tenorio, Alex; Hoibak, Sarah; Aguirre, Angel Rosas; Toomer, Elizabeth; Rodriguez, Hugo; Llanos Cuentas, Alejandro; D'Alessandro, Umberto; Gamboa, Dionicia; Erhart, Annette

    2013-01-01

    While coverage of long-lasting insecticide-treated nets (LLIN) has steadily increased, a growing number of studies report gaps between net ownership and use. We conducted a mixed-methods social science study assessing the importance of net preference and use after Olyset® LLINs were distributed through a mass campaign in rural communities surrounding Iquitos, the capital city of the Amazonian region of Peru. The study was conducted in the catchment area of the Paujil and Cahuide Health Centres (San Juan district) between July 2007 and November 2008. During a first qualitative phase, participant observation and in-depth interviews collected information on key determinants for net preference and use. In a second quantitative phase, a survey among recently confirmed malaria patients evaluated the acceptability and use of both LLINs and traditional nets, and a case control study assessed the association between net preference/use and housing structure (open vs. closed houses). A total of 10 communities were selected for the anthropological fieldwork and 228 households participated in the quantitative studies. In the study area, bed nets are considered part of the housing structure and are therefore required to fulfil specific architectural and social functions, such as providing privacy and shelter, which the newly distributed Olyset® LLINs ultimately did not. The LLINs' failure to meet these criteria could mainly be attributed to their large mesh size, transparency and perceived ineffectiveness to protect against mosquitoes and other insects, resulting in 63.3% of households not using any of the distributed LLINs. Notably, LLIN usage was significantly lower in houses with no interior or exterior walls (35.2%) than in those with walls (73.8%) (OR = 5.2, 95CI [2.2; 12.3], p<0.001). Net preference can interfere with optimal LLIN use. In order to improve the number of effective days of LLIN protection per dollar spent, appropriate quantitative and qualitative methods for collecting information on net preference should be developed before any LLIN procurement decision is made.

  19. Traditional Nets Interfere with the Uptake of Long-Lasting Insecticidal Nets in the Peruvian Amazon: The Relevance of Net Preference for Achieving High Coverage and Use

    PubMed Central

    Grietens, Koen Peeters; Muela Ribera, Joan; Soto, Veronica; Tenorio, Alex; Hoibak, Sarah; Aguirre, Angel Rosas; Toomer, Elizabeth; Rodriguez, Hugo; Llanos Cuentas, Alejandro; D'Alessandro, Umberto; Gamboa, Dionicia; Erhart, Annette

    2013-01-01

    Background While coverage of long-lasting insecticide-treated nets (LLIN) has steadily increased, a growing number of studies report gaps between net ownership and use. We conducted a mixed-methods social science study assessing the importance of net preference and use after Olyset® LLINs were distributed through a mass campaign in rural communities surrounding Iquitos, the capital city of the Amazonian region of Peru. Methods The study was conducted in the catchment area of the Paujil and Cahuide Health Centres (San Juan district) between July 2007 and November 2008. During a first qualitative phase, participant observation and in-depth interviews collected information on key determinants for net preference and use. In a second quantitative phase, a survey among recently confirmed malaria patients evaluated the acceptability and use of both LLINs and traditional nets, and a case control study assessed the association between net preference/use and housing structure (open vs. closed houses). Results A total of 10 communities were selected for the anthropological fieldwork and 228 households participated in the quantitative studies. In the study area, bed nets are considered part of the housing structure and are therefore required to fulfil specific architectural and social functions, such as providing privacy and shelter, which the newly distributed Olyset® LLINs ultimately did not. The LLINs' failure to meet these criteria could mainly be attributed to their large mesh size, transparency and perceived ineffectiveness to protect against mosquitoes and other insects, resulting in 63.3% of households not using any of the distributed LLINs. Notably, LLIN usage was significantly lower in houses with no interior or exterior walls (35.2%) than in those with walls (73.8%) (OR = 5.2, 95CI [2.2; 12.3], p<0.001). Conclusion Net preference can interfere with optimal LLIN use. In order to improve the number of effective days of LLIN protection per dollar spent, appropriate quantitative and qualitative methods for collecting information on net preference should be developed before any LLIN procurement decision is made. PMID:23300943

  20. An exploratory study of treated-bed nets in Timor-Leste: patterns of intended and alternative usage

    PubMed Central

    2011-01-01

    Background The Timor-Leste Ministry of Health has recently finalized the National Malaria Control Strategy for 2010-2020. A key component of this roadmap is to provide universal national coverage with long-lasting insecticide-treated nets (LLINs) in support of achieving the primary goal of reducing both morbidity and mortality from malaria by 30% in the first three years, followed by a further reduction of 20% by end of the programme cycle in 2020 [1]. The strategic plan calls for this target to be supported by a comprehensive information, education and communication (IEC) programme; however, there is limited prior research into household and personal usage patterns to assist in the creation of targeted, effective, and socio-culturally specific behaviour change materials. Methods Nine separate focus group discussions (FGDs) were carried out in Dili, Manatuto, and Covalima districts, Democratic Republic of Timor-Leste, in July 2010. These focus groups primarily explored themes of perceived malaria risk, causes of malaria, net usage patterns within families, barriers to correct and consistent usage, and the daily experience of users (both male and female) in households with at least one net. Comprehensive qualitative analysis utilized open source analysis software. Results The primary determinants of net usage were a widespread perception that nets could or should only be used by pregnant women and young children, and the availability of sufficient sleeping space under a limited number of nets within households. Both nuisance biting and disease prevention were commonly cited as primary motivations for usage, while seasonality was not a significant factor. Long-term net durability and ease of hanging were seen as key attributes in net design preference. Very frequent washing cycles were common, potentially degrading net effectiveness. Finally, extensive re-purposing of nets (fishing, protecting crops) was both reported and observed, and may significantly decrease availability of nighttime sleeping space for all family members if distributed nets do not remain within the household. Conclusions Emphasizing that net usage is acceptable and important for all family members regardless of age or gender, and addressing the complex behavioural economics of alternative net usages could have significant impacts on malaria control efforts in Timor-Leste, as the country's programmes make progress towards universal net coverage. PMID:21777415

  1. A new method for estimating the turbulent heat flux at the bottom of the daily mixed layer

    NASA Technical Reports Server (NTRS)

    Imawaki, Shiro; Niiler, Pearn P.; Gautier, Catherine H.; Knox, Robert A.; Halpern, David

    1988-01-01

    Temperature data in the mixed layer and net solar irradiance data at the sea surface are used to estimate the vertical turbulent heat flux at the bottom of the daily mixed layer. The method is applied to data obtained in the eastern tropical Pacific, where the daily cycle in the temperature field is confined to the upper 10-25 m. Equatorial turbulence measurements indicate that the turbulent heat flux is much greater during nighttime than daytime.

  2. Solar energy system performance evaluation. Seasonal report for SEECO Lincoln, Lincoln, Nebraska

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The Solar Engineering and Equipment Company (SEECO) Lincoln solar energy system, designed for space heating only, is described and its operational performance for a 12 month period from April 1979 through March 1980 is evaluated. The system met 27 percent of the space heating load; however, system losses into the heated space from the storage bin and ductwork were significant. Reducing these losses would add appreciably to the system's efficiency. Net fossil energy savings were 11.31 million BTUs.

  3. Skylight energy balance analysis procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dietz, P.S.; Murdoch, J.B.; Pokoski, J.L.

    1981-10-01

    This paper provides a systematic method for calculating the total, net differential energy balance observed when sections of the roof of a building are replaced with skylights. Among the topics discussed are the effect of solar gains, dome and curb conduction heat transfers, equivalent roof area heat transfers, infiltration heat transfers, artificial lighting energy requirements, and illumination savings from skylights. The paper also provides much of the supplementary information needed to complete these energy calculations. This information appears in the form of appendices, tables, and graphs. 9 refs.

  4. The Climatological Seasonal Response of the Ocean Mixed Layer in the Equatorial and Tropical Pacific Ocean

    DTIC Science & Technology

    1988-03-01

    response of the ocean and the seasonal changes in atmospheric forcing. The pattern of 20 DiSTPIBUTION/ AVAILABILIT Y OF aRS7RACT 21 ABSTRACT SECURITY...Speed with M LD .............................. 50 3.20 Time Rate of Change of Heat in the Water Column at 155 oE Contour Interval is 35W m 2...52 3.21 Dilerence of Net Surface Heating ad Heat .* the Water Column at 155 oE

  5. Measuring surface fluxes in CAPE

    NASA Technical Reports Server (NTRS)

    Kanemasu, E. T.; D-Shah, T.; Nie, Dalin

    1992-01-01

    Two stations (site 1612 and site 2008) were operated by the University of Georgia group from 6 July 1991 to 18 August 1991. The following data were collected continuously: surface energy fluxes (i.e., net radiation, soil heat fluxes, sensible heat flux and latent heat flux), air temperature, vapor pressure, soil temperature (at 1 cm depth), and precipitation. Canopy reflectance and light interception data were taken three times at each site between 6 July and 18 August. Soil moisture content was measured twice at each site.

  6. Analysis of Near-Surface Oceanic Measurements Obtained During the Low-Wind Component of the Coupled Boundary Layers and Air-Sea Transfer (CBLAST) Experiment

    DTIC Science & Technology

    2006-09-30

    temperature and the upwelling IR radiative heat flux were obtained from a pyrometer . The heat fluxes are combined to compute the net heat flux into or out...sampled acoustic Doppler velocimeters (ADVs) and thermistors (Figure 1b). These measurements provide inertial-range estimates of dissipation rates...horizontal velocity at the sea surface were obtained with a “fanbeam” acoustic Doppler current profiler (ADCP), which produces spatial maps of the

  7. In vivo induction of neutrophil extracellular traps by Mycobacterium tuberculosis in a guinea pig model.

    PubMed

    Filio-Rodríguez, Georgina; Estrada-García, Iris; Arce-Paredes, Patricia; Moreno-Altamirano, María M; Islas-Trujillo, Sergio; Ponce-Regalado, M Dolores; Rojas-Espinosa, Oscar

    2017-10-01

    In 2004, a novel mechanism of cellular death, called 'NETosis', was described in neutrophils. This mechanism, different from necrosis and apoptosis, is characterized by the release of chromatin webs admixed with microbicidal granular proteins and peptides (NETs). NETs trap and kill a variety of microorganisms. Diverse microorganisms, including Mycobacterium tuberculosis, are NET inducers in vitro. The aim of this study was to examine whether M. tuberculosis can also induce NETs in vivo and if the NETs are bactericidal to the microorganism. Guinea pigs were intradermally inoculated with M. tuberculosis H37Rv, and the production of NETs was investigated at several time points thereafter. NETs were detected as early as 30 min post-inoculation and were clearly evident by 4 h post-inoculation. NETs produced in vivo contained DNA, myeloperoxidase, elastase, histones, ROS and acid-fast bacilli. Viable and heat-killed M. tuberculosis, as well as Mycobacterium bovis BCG were efficient NET inducers, as were unilamellar liposomes prepared with lipids from M. tuberculosis. In vitro, guinea pig neutrophils also produced NETs in response to M. tuberculosis. However, neither the in vivo nor the in vitro-produced NETs were able to kill M. tuberculosis. Nevertheless, in vivo, neutrophils might propitiate recruitment and activation of more efficient microbicidal cells.

  8. Measurements of Combined Axial Mass and Heat Transport in He II.

    ERIC Educational Resources Information Center

    Johnson, Warren W.; Jones, Michael C.

    An experiment was performed that allowed measurements of both axial mass and heat transport of He-II (the superfluid phase of helium 4) in a long tube. The apparatus allowed the pressure difference and the temperature difference across the flow tube to each be independently adjusted, and the resulting steady-state values of net fluid velocity and…

  9. Electrification of buildings and industry in the United States: Drivers, barriers, prospects, and policy approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deason, Jeff; Wei, Max; Leventis, Greg

    The report offers several use cases and case studies of electrification in buildings and industry: air source heat pumps for space heating, zero net energy buildings, electric water heaters and demand response, electric arc furnaces, and electric boilers. Finally, the report suggests several areas for further research to better understand and advance beneficial electrification.

  10. Surface energy budget and turbulent fluxes at Arctic terrestrial sites

    NASA Astrophysics Data System (ADS)

    Grachev, Andrey; Persson, Ola; Uttal, Taneil; Konopleva-Akish, Elena; Crepinsek, Sara; Cox, Christopher; Fairall, Christopher; Makshtas, Alexander; Repina, Irina

    2017-04-01

    Determination of the surface energy budget (SEB) and all SEB components at the air-surface interface are required in a wide variety of applications including atmosphere-land/snow simulations and validation of the surface fluxes predicted by numerical models over different spatial and temporal scales. Here, comparisons of net surface energy budgets at two Arctic sites are made using long-term near-continuous measurements of hourly averaged surface fluxes (turbulent, radiation, and soil conduction). One site, Eureka (80.0 N; Nunavut, Canada), is located in complex topography near a fjord about 200 km from the Arctic Ocean. The other site, Tiksi (71.6 N; Russian East Siberia), is located on a relatively flat coastal plain less than 1 km from the shore of Tiksi Bay, a branch of the Arctic Ocean. We first analyzed diurnal and annual cycles of basic meteorological parameters and key SEB components at these locations. Although Eureka and Tiksi are located on different continents and at different latitudes, the annual course of the surface meteorology and SEB components are qualitatively similar. Surface energy balance closure is a formulation of the conservation of energy principle. Our direct measurements of energy balance for both Arctic sites show that the sum of the turbulent sensible and latent heat fluxes and the ground (conductive) heat flux systematically underestimate the net radiation by about 25-30%. This lack of energy balance closure is a fundamental and pervasive problem in micrometeorology. We discuss a variety of factors which may be responsible for the lack of SEB closure. In particular, various storage terms (e.g., air column energy storage due to radiative and/or sensible heat flux divergence, ground heat storage above the soil flux plate, energy used in photosynthesis, canopy biomass heat storage). For example, our observations show that the photosynthesis storage term is relatively small (about 1-2% of the net radiation), but about 8-12% of the imbalance magnitude. All turbulent fluxes are highly correlated with net radiation because this balance between solar and longwave radiation is the principal energy source for daytime surface warming, evaporation, and photosynthesis. We find that turbulent fluxes of carbon dioxide and sensible heat are closely linked and, on average, change sign synchronously during the diurnal and annual cycles. The work is supported by the NOAA Climate Program Office, the U.S. National Science Foundation (NSF) with award ARC 11-07428, and by the U.S. Civilian Research & Development Foundation (CRDF) with award RUG1-2976-ST-10.

  11. Soil water evaporation during the dry season in an arid zone

    NASA Astrophysics Data System (ADS)

    Agam (Ninari), Nurit; Berliner, Pedro R.; Zangvil, Abraham; Ben-Dor, Eyal

    2004-08-01

    The objective of this study was to assess the relative magnitude of latent heat flux density over a bare loess soil in the Negev desert throughout the dry season, during which the atmospheric models usually assume the lack of latent heat flux. The measurements were carried out in the northern Negev, Israel, over a bare loess soil, during nine 24-hour field campaigns throughout the dry season of 2002. In addition to a micrometeorological station that was set up in the research site, an improved microlysimeter was installed. The representativity of the microlysimeter was assessed by comparing its surface temperature to that of the surrounding surface using thermal images acquired on an hourly basis during several campaigns. It was found that although the water content of the uppermost soil is significantly lower than the wilting point, for which most of the commonly used meteorological models would assume no latent heat flux, the latter was ˜20% of the net-radiation during the night and 10-15% during the day. It is therefore concluded that latent heat flux plays a major role in the dissipation of the net radiation during the dry season in the Negev desert.

  12. Heating Has No Effect on the Net Protein Utilisation from Egg Whites in Rats

    PubMed Central

    Takahashi, Yayoi; Kimura, Mamoru; Masuda, Yasunobu; Kunou, Masaaki

    2017-01-01

    Egg whites (EW) are a good source of protein; however, they are typically heated prior to consumption. Therefore, we investigated the effects of different heating conditions on the protein utilisation rate of EW. Male Sprague-Dawley rats (n = 36, 198 ± 1 g) were divided into six groups and fed American Institute of Nutrition-76 chow containing unheated EW, soft-boiled EW, boiled EW, milk whey protein, soybean protein, or no protein over a 10-day period using pair-feeding. Urine and faeces were sampled daily beginning on day 5 to measure nitrogen content and the net protein utilisation (NPU) rate. The soybean protein group had a significantly lower level of food intake and was thus excluded from subsequent analyses. The NPU value was similar among the unheated, soft-boiled, and boiled EW groups (97.5 ± 0.4, 96.5 ± 0.1, and 96.5 ± 0.7, resp.). The EW group values were significantly higher than the whey group values (90.5 ± 1.0). These results show that EW serve as a good source of protein, irrespective of heating. PMID:28337477

  13. Sensitivity analysis of coupled processes and parameters on the performance of enhanced geothermal systems.

    PubMed

    Pandey, S N; Vishal, Vikram

    2017-12-06

    3-D modeling of coupled thermo-hydro-mechanical (THM) processes in enhanced geothermal systems using the control volume finite element code was done. In a first, a comparative analysis on the effects of coupled processes, operational parameters and reservoir parameters on heat extraction was conducted. We found that significant temperature drop and fluid overpressure occurred inside the reservoirs/fracture that affected the transport behavior of the fracture. The spatio-temporal variations of fracture aperture greatly impacted the thermal drawdown and consequently the net energy output. The results showed that maximum aperture evolution occurred near the injection zone instead of the production zone. Opening of the fracture reduced the injection pressure required to circulate a fixed mass of water. The thermal breakthrough and heat extraction strongly depend on the injection mass flow rate, well distances, reservoir permeability and geothermal gradients. High permeability caused higher water loss, leading to reduced heat extraction. From the results of TH vs THM process simulations, we conclude that appropriate coupling is vital and can impact the estimates of net heat extraction. This study can help in identifying the critical operational parameters, and process optimization for enhanced energy extraction from a geothermal system.

  14. Sea Ice, Clouds, Sunlight, and Albedo: The Umbrella Versus the Blanket

    NASA Astrophysics Data System (ADS)

    Perovich, D. K.

    2017-12-01

    The Arctic sea ice cover has undergone a major decline in recent years, with reductions in ice extent, ice thickness, and ice age. Understanding the feedbacks and forcing driving these changes is critical in improving predictions. The surface radiation budget plays a central role in summer ice melt and is governed by clouds and surface albedo. Clouds act as an umbrella reducing the downwelling shortwave, but also serve as a blanket increasing the downwelling longwave, with the surface albedo also determining the net balance. Using field observations from the SHEBA program, pairs of clear and cloudy days were selected for each month from May through September and the net radiation flux was calculated for different surface conditions and albedos. To explore the impact of albedo we calculated a break even albedo, where the net radiation for cloudy skies is the same as clear skies. For albedos larger than the break-even value the net radiation flux is smaller under clear skies compared to cloudy skies. Break-even albedos ranged from 0.30 in September to 0.58 in July. For snow covered or bare ice, clear skies always resulted in less radiative heat input. In contrast, leads always had, and ponds usually had, more radiative heat input under clear skies than cloudy skies. Snow covered ice had a net radiation flux that was negative or near zero under clear skies resulting in radiative cooling. We combined the albedo of individual ice types with the area of those ice types to calculate albedos averaged over a 50 km x 50 km area. The July case had the smallest areally averaged albedo of 0.50. This was less than the breakeven albedo, so cloudy skies had a smaller net radiation flux than clear skies. For the cases from the other four months, the areally averaged albedo was greater than the break-even albedo. The areally averaged net radiation flux was negative under clear skies for the May and September cases.

  15. Migration and sensory properties of plastics-based nets used as food-contacting materials under ambient and high temperature heating conditions.

    PubMed

    Kontominas, M G; Goulas, A E; Badeka, A V; Nerantzaki, A

    2006-06-01

    Overall migration from a wide range of commercial plastics-based netting materials destined to be used as either meat or vegetable packaging materials into the fatty food simulant isooctane or the aqueous simulant distilled water, respectively, was studied. In addition, sensory tests of representative netting materials were carried out in bottled water in order to investigate possible development of off-odour/taste and discoloration in this food simulant as a result of migration from the netting material. Sensory tests were supplemented by determination of the volatile compounds' profile in table water exposed to the netting materials using SPME-GC/MS. Test conditions for packaging material/food simulant contact and method of overall migration analysis were according to European Union Directives 90/128 (EEC, 1990) and 2002/72 (EEC, 2002). The results showed that for both PET and polyethylene-based netting materials, overall migration values into distilled water ranged between 11.5 and 48.5 mg l(-1), well below the upper limit (60 mg l(-1)) for overall migration values from plastics-packaging materials set by the European Union. The overall migration values from netting materials into isooctane ranged between 38.0 and 624.0 mg l(-1), both below and above the European Union upper limit for migration. Sensory tests involving contact of representative samples with table water under refluxing (100 degrees C/4 h) conditions showed a number of the netting materials produced both off-odour and/or taste as well as discoloration of the food simulant rendering such materials unfit for the packaging of foodstuffs in applications involving heating at elevated temperatures. GC/MS analysis showed the presence of numerous volatile compounds being produced after netting materials/water contact under refluxing conditions. Although it is extremely difficult to establish a clear correlation between sensory off-odour development and GC/MS volatile compounds' profile, it may be postulated that plastics oxidation products such as hexanal, heptanal, octanal and 2,6 di-tert-butylquinone may contribute to off-odour development using commercially bottled table water as a food simulant. Likewise, compounds such as carbon disulfide, [1,1'-biphenyl]-2-ol and propanoic acid, 2 methyl 1-(1,1-dimethyl)-2-methyl-1,3-propanediyl ester probably originating from cotton and rubber components of netting materials may also contribute to off-odour/taste development.

  16. District heating and cooling systems for communities through power plant retrofit distribution network, Phase 2. Final report, 1 March 1980-31 January 1984. Volume II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1984-01-31

    This volume begins with an Introduction summarizing the history, methodology and scope of the study, the project team members and the private and public groups consulted in the course of the study. The Load and Service Area Assessment follows, including: a compilation and analysis of existing statistical thermal load data from census data, industrial directories, PSE and G records and other sources; an analysis of responses to a detailed, 4-page thermal load questionnaire; data on public buildings and fuel and energy use provided by the New Jersey Dept. of Energy; and results of other customer surveys conducted by PSE andmore » G. A discussion of institutional questions follows. The general topic of rates is then discussed, including a draft hypothetical Tariff for Thermal Services. Financial considerations are discussed including a report identifying alternative ownership/financing options for district heating systems and the tax implications of these options. Four of these options were then selected by PSE and G and a financial (cash-flow) analysis done (by the PSE and G System Planning Dept.) in comparison with a conventional heating alternative. Year-by-year cost of heat ($/10/sup 6/ Btu) was calculated and tabulated, and the various options compared.« less

  17. Near infrared spatial frequency domain fluorescence imaging of tumor phantoms containing erythrocyte-derived optical nanoplatforms

    NASA Astrophysics Data System (ADS)

    Burns, Joshua M.; Schaefer, Elise; Anvari, Bahman

    2018-02-01

    Light-activated theranostic constructs provide a multi-functional platform for optical imaging and phototherapeutic applications. Our group has engineered nano-sized vesicles derived from erythrocytes that encapsulate the FDAapproved near infrared (NIR) absorber indocyanine green (ICG). We refer to these constructs as NIR erythrocytemimicking transducers (NETs). Once photo-excited by NIR light these constructs can transduce the photons energy to emit fluorescence, generate heat, or induce chemical reactions. In this study, we investigated fluorescence imaging of NETs embedded within tumor phantoms using spatial frequency domain imaging (SFDI). Using SFDI, we were able to fluorescently image simulated tumors doped with different concentration of NETs. These preliminary results suggest that NETs can be used in conjunction with SFDI for potential tumor imaging applications.

  18. 7 CFR 51.1565 - Internal defects.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Browning, Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5 percent waste 10 percent waste... Occurring entirely within the vascular ring Internal Brown Spot and Similar Discoloration (Heat Necrosis...

  19. 7 CFR 51.1565 - Internal defects.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Browning, Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5 percent waste 10 percent waste... Occurring entirely within the vascular ring Internal Brown Spot and Similar Discoloration (Heat Necrosis...

  20. Using social impact borrowing to expand preschool through third grade programs in urban public schools.

    PubMed

    Temple, Judy A; Reynolds, Arthur J

    Budget constraints and difficulty raising taxes limit school districts from expanding education programming even when research shows that additional expenditures would generate economic benefits that are greater than costs. Recently, coalitions of private investors, philanthropists, education practitioners, and government finance analysts have emerged to create opportunities to expand education services that promise high rates of social net benefits without raising taxes or reducing other expenditures. These collaborators have a strong interest in obtaining careful estimates of educational program effectiveness. We describe the use of social-impact borrowing to increase access to the Child-Parent Center preschool-through-third-grade intervention for at-risk students in the Chicago Public School District. The partners include the city, school district, investors, nonprofit organizations, and a university. The key to the feasibility of social-impact borrowing is the ability to document that early intervention can reduce the need for later special-education services. With the help of private investors and nonprofit organizations, it is possible for public school districts to finance services with funds from private sources and use future cost savings to repay this debt. We discuss how social-impact borrowing is being used in Chicago and in Salt Lake County as the nation's first two instances of using pay-for-performance social-impact borrowing to support early education.

  1. Developing a strategy for improving efficiency in the heating sector in central and eastern Europe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, A.S.

    1995-12-31

    Heating is a vital energy service in Central and Eastern Europe, but the current delivery mechanisms are riddled with problems. District heating (DH) in its present technical form and with the present management structures is an inefficient system which produces expensive heat. Customers cannot control it and react to overheating by opening windows, even in winter. DH facilities together with other forms of individual heating are responsible for air pollution, causing severe impacts on the health of urban residents. The issues relating to DH are discussed, the first World Bank activities and experiences with projects in Poland are analyzed, andmore » the cornerstones of a strategy to support future World Bank financing and the development of sound heating policies in CEE are presented.« less

  2. Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

  3. [Effect of comprehensive prevention and control of soil-transmitted nematodiasis in Runzhou District of Zhenjiang City].

    PubMed

    Xia, Ai; Tao, Heng-Ye; Zhao, Ya-Ming; Jiang, Jun; Wang, Jin; Mei, Jin

    2014-12-01

    To evaluate the effect of comprehensive prevention and control of soil-transmitted nematodiasis in Runzhou District, Zhenjiang City, Jiangsu Province from 1997 to 2012. The comprehensive prevention and control measures included the helminthicide, health education, improvement of water supplier and harmless toilets, and these measures were implemented continuously. At the same time, the infection rates of soil-transmitted nematodes, the local economic indicators, and the coverage rates of tap water and harmless toilets were surveyed. The mass chemotherapy was performed for 202 100 person-times and the diagnosed chemotherapy was performed for 2 006 person-times in Runzhou District from 1997 to 2012. The awareness rates of health knowledge were 57.18% in 1997, and 95.62% in 2012. The coverage rates of tap water and harmless toilets were 10.14% and 10.21% in 1997, and 100.0% and 90.38% in 2012, respectively. There were negative correlations between the awareness rate of per capita GDP, per capita net income, coverage rates of tap water, coverage rates of harmless toilets, health knowledge and the infection rate of soil-transmitted nematodes, respectively (r(per capitaGDP) = -0.526, P < 0.05; r(per capita net income) = -0.671, P < 0.01; r(coverage rates of tap water) = -0.936, P < 0.01; r(coverage rates of harmless toilets) = -0.922, P < 0.01; r(awareness) = -0.774, P < 0.01). The statistical analysis showed that the infection rate of soil-transmitted nematodes had a downward trend as an exponential curve in Runzhou District from 1997 to 2012 (y = 42.031 7e(-0.357 6x), R2 = 0.803 6, F = 57.28, P = 0.000). The infection rate of degradation by an annual rate was 29.18%. The infection rate in farmers was significantly higher than that in students (χ2 = 17.998, P < 0.01). There was no significant difference between men and women in the infection rate of soil-transmitted nematodes (χ2 = 3.627, P = 0.057). The comprehensive prevention and control measures and the development of social economy contribute to the steady decline of soil-transmitted nematode infections.

  4. Seasonal energy and water balance of a Phragmites australis-dominated wetland in the Republican River basin of south-central Nebraska (USA)

    NASA Astrophysics Data System (ADS)

    Lenters, J. D.; Cutrell, G. J.; Istanbulluoglu, E.; Scott, D. T.; Herrman, K. S.; Irmak, A.; Eisenhauer, D. E.

    2011-09-01

    SummaryClimate and vegetation strongly influence the water cycle on local to regional scales. A change in the surface energy and water balance, especially in dry climatic regions, can have a significant impact on local water availability and, therefore, water resource management. The purpose of this study is to quantify the energy and water balance of a riparian wetland in a subhumid region of the central US, as well as the role of seasonal climate variability and vegetation phenology. The site is located in the Republican River basin in south-central Nebraska, where decreases in streamflow have been observed in recent decades. In an effort to reduce consumptive water use from evapotranspiration (ET), and thereby reclaim surface water, invasive species such as Phragmites australis have been removed throughout the riparian corridor of the river basin. In this study, we used energy/water balance monitoring stations, a Large Aperture Scintillometer (LAS), and numerous water and soil temperature probes to determine the energy and water balance during the 2009 growing season (April 11-October 3). Sensible heat flux was measured using the LAS, while ET was calculated as a residual of the energy balance (i.e., net radiation minus sensible heat flux and heat storage rates in the canopy, water, and soil). Rigorous quality control and uncertainty analyses were performed, and comparisons were also made with ET rates calculated via the simpler Priestley-Taylor method. Results of the energy budget analysis indicate that the average ET rate for the wetland during the growing season was 4.4 mm day -1, with a maximum daily rate of 8.2 mm day -1 (occurring on June 29). Precipitation during the same 176-day period averaged 2.7 mm day -1. Net radiation and vegetation phenology were found to be the two largest drivers of seasonal variability in ET. Sensible heat flux was significantly larger than latent heat flux early in the season, when standing vegetation in the wetland was still dry and brown. By late May and early June, however, Bowen ratios had declined well below 0.5 in response to greener and more abundant vegetation, higher transpiration rates, and reduced sensible heat flux. Heat storage rates in the wetland were dominated by changes in water temperature (as compared to soil or canopy heat storage) and comprised a significant portion of the hourly energy balance. On daily mean timescales, changes in the rate of heat storage corresponded to ˜13% of the variability in net radiation, while for the season-long average, the heat storage term was found to be essentially negligible. The Priestley-Taylor equation provided a reasonable estimate of ET during the height of the growing season but significantly overestimated ET during the beginning of the season (since it could not account for large sensible heat fluxes from the dry vegetation). Analysis of the wetland water balance showed seasonal variations in water level that were similar to changes in cumulative water inputs (i.e., precipitation minus ET). Portions of the season when the two curves had differing rates of change indicated periods of net water influx or outflux from other sources (primarily groundwater).

  5. CERES EBAF Info

    Atmospheric Science Data Center

    2014-01-24

    ... fluxes, where TOA net flux is constrained to ocean heat storage. - Surface: Computed surface clear-sky and all-sky fluxes consistent with the EBAF-TOA fluxes. Data Products:  EBAF-TOA EBAF-Surface ...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pind, C.

    The SECURE heating reactor was designed by ASEA-ATOM as a realistic alternative for district heating in urban areas and for supplying heat to process industries. SECURE has unique safety characteristics, that are based on fundamental laws of physics. The safety does not depend on active components or operator intervention for shutdown and cooling of the reactor. The inherent safety characteristics of the plant cannot be affected by operator errors. Due to its very low environment impact, it can be sited close to heat consumers. The SECURE heating reactor has been shown to be competitive in comparison with other alternatives formore » heating Helsinki and Seoul. The SECURE heating reactor forms a basis for the power-producing SECURE-P reactor known as PIUS (Process Inherent Ultimate Safety), which is based on the same inherent safety principles. The thermohydraulic function and transient response have been demonstrated in a large electrically heated loop at the ASEA-ATOM laboratories.« less

  7. Flux Measurements of Trace Gases, Aerosols and Energy from the Urban Core of Mexico City

    NASA Astrophysics Data System (ADS)

    Velasco, E.; Molina, L.; Lamb, B.; Pressley, S.; Grivicke, R.; Westberg, H.; Jobson, T.; Allwine, E.; Coons, T.; Jimenez, J.; Nemitz, E.; Alexander, L. M.; Worsnop, D.; Ramos, R.

    2007-05-01

    As part of the MILAGRO field campaign in March 2006 we deployed a flux system in a busy district of Mexico City surrounded by congested avenues. The flux system consisted of a tall tower instrumented with fast-response sensors coupled with eddy covariance (EC) techniques to measure fluxes of volatile organic compounds (VOCs), CO2, CO, aerosols and energy. The measured fluxes represent direct measurements of emissions that include all major and minor emission sources from a typical residential and commercial district. In a previous study we demonstrated that the EC techniques are valuable tools to evaluate emissions inventories in urban areas, and understand better the atmospheric chemistry and the role that megacities play in global change. We measured fluxes of olefins using a Fast Olefin Sensor (FOS) and the EC technique, fluxes of aromatic and oxygenated VOCs by Proton Transfer Reaction-Mass Spectroscopy (PTR-MS) and the disjunct eddy covariance (DEC) technique, fluxes of CO2 and H2O with an open path Infrared Gas Analyzer (IRGA) and the EC technique, fluxes of CO using a modified gradient method and a commercial CO instrument, and fluxes of aerosols (organics, nitrates and sulfates) using an Aerodyne Aerosol Mass Spectrometer (AMS) and the EC technique. In addition we used a disjunct eddy accumulation (DEA) system to extend the number of VOCs. This system collected whole air samples as function of the direction of the vertical wind component, and the samples were analyzed on site using gas chromatography / flame ionization detection (GC-FID). We also measured fluxes of sensible and latent heat by EC and the radiation components with a net radiometer. Overall, these flux measurements confirm the results of our previous flux measurements in Mexico City in terms of the magnitude, composition, and distribution. We found that the urban surface is a net source of CO2 and VOCs. The diurnal patterns show clear anthropogenic signatures, with important contributions from vehicular traffic. The DEA results for individual hydrocarbons show that the alkane fluxes are considerably higher than alkene fluxes, which is consistent with ambient concentration measurements and with the emission inventory for Mexico City. CO fluxes, estimated from a modified gradient technique, were more than 10% of the measured CO2 fluxes (on a molar basis) which is much higher than is generally expected for combustion efficiencies in mobile and other sources. Investigation of this result is underway. The energy balance distribution and radiative parameters observed are similar to distributions and parameters reported for other urban sites.

  8. Plant based insect repellent and insecticide treated bed nets to protect against malaria in areas of early evening biting vectors: double blind randomised placebo controlled clinical trial in the Bolivian Amazon.

    PubMed

    Hill, N; Lenglet, A; Arnéz, A M; Carneiro, I

    2007-11-17

    To determine the effectiveness in reducing malaria of combining an insect repellent with insecticide treated bed nets compared with the nets alone in an area where vector mosquitoes feed in the early evening. A double blind, placebo controlled cluster-randomised clinical study. Rural villages and peri-urban districts in the Bolivian Amazon. 4008 individuals in 860 households. All individuals slept under treated nets; one group also used a plant based insect repellent each evening, a second group used placebo. Episodes of Plasmodium falciparum or P vivax malaria confirmed by rapid diagnostic test or blood slide, respectively. We analysed 15,174 person months at risk and found a highly significant 80% reduction in episodes of P vivax in the group that used treated nets and repellent (incidence rate ratio 0.20, 95% confidence interval 0.11 to 0.38, P<0.001). Numbers of P falciparum cases during the study were small and, after adjustment for age, an 82% protective effect was observed, although this was not significant (0.18, 0.02 to 1.40, P=0.10). Reported episodes of fever with any cause were reduced by 58% in the group that used repellent (0.42, 0.31 to 0.56, P<0.001). Insect repellents can provide protection against malaria. In areas where vectors feed in the early evening, effectiveness of treated nets can be significantly increased by using repellent between dusk and bedtime. This has important implications in malaria vector control programmes outside Africa and shows that the combined use of treated nets and insect repellents, as advocated for most tourists travelling to high risk areas, is fully justified. NCT 00144716.

  9. Geothermal heating facilities for Frontier Inn, Susanville, California

    NASA Astrophysics Data System (ADS)

    1982-03-01

    A 38 unit motel composed of six major sections (coffee shop, A frame units, apartments, back units, two story units and office) was built over a number of years and exhibits widely varying types of construction. Space heating is provided by primarily electric resistance equipment with some propane use. Domestic hot water is provided primarily by propane with some electric resistance. The coffee shop uses fuel oil for both space and domestic hot water heating. A geothermal district heating system is being installed. Although the motel site is not located in the area of construction activity, it is expected that the pipeline will be extended. The potential of retrofitting the existing heating facilities at the inn to geothermal is studied.

  10. Report of the 1988 2-D Intercomparison Workshop, chapter 3

    NASA Technical Reports Server (NTRS)

    Jackman, Charles H.; Brasseur, Guy; Soloman, Susan; Guthrie, Paul D.; Garcia, Rolando; Yung, Yuk L.; Gray, Lesley J.; Tung, K. K.; Ko, Malcolm K. W.; Isaken, Ivar

    1989-01-01

    Several factors contribute to the errors encountered. With the exception of the line-by-line model, all of the models employ simplifying assumptions that place fundamental limits on their accuracy and range of validity. For example, all 2-D modeling groups use the diffusivity factor approximation. This approximation produces little error in tropospheric H2O and CO2 cooling rates, but can produce significant errors in CO2 and O3 cooling rates at the stratopause. All models suffer from fundamental uncertainties in shapes and strengths of spectral lines. Thermal flux algorithms being used in 2-D tracer tranport models produce cooling rates that differ by as much as 40 percent for the same input model atmosphere. Disagreements of this magnitude are important since the thermal cooling rates must be subtracted from the almost-equal solar heating rates to derive the net radiative heating rates and the 2-D model diabatic circulation. For much of the annual cycle, the net radiative heating rates are comparable in magnitude to the cooling rate differences described. Many of the models underestimate the cooling rates in the middle and lower stratosphere. The consequences of these errors for the net heating rates and the diabatic circulation will depend on their meridional structure, which was not tested here. Other models underestimate the cooling near 1 mbar. Suchs errors pose potential problems for future interactive ozone assessment studies, since they could produce artificially-high temperatures and increased O3 destruction at these levels. These concerns suggest that a great deal of work is needed to improve the performance of thermal cooling rate algorithms used in the 2-D tracer transport models.

  11. Relationships between radiation, clouds, and convection during DYNAMO

    DOE PAGES

    Ciesielski, Paul E.; Johnson, Richard H.; Jiang, Xianan; ...

    2017-02-16

    In this paper, the relationships between radiation, clouds, and convection on an intraseasonal time scale are examined with data taken during the Dynamics of the Madden-Julian Oscillation (MJO) field campaign. Specifically, column-net, as well as vertical profiles of radiative heating rates, computed over Gan Island in the central Indian Ocean (IO) are used along with an objective analysis of large-scale fields to examine three MJO events that occurred during the 3 month period (October to December 2011) over this region. Longwave (LW) and shortwave radiative heating rates exhibit tilted structures, reflecting radiative effects associated with the prevalence of shallow cumulusmore » during the dry, suppressed MJO phase followed by increasing deep convection leading into the active phase. As the convection builds going into the MJO active phase, there are increasingly top-heavy anomalous radiative heating rates while the column-net radiative cooling rate Q r progressively decreases. Temporal fluctuations in the cloud radiative forcing, being quite sensitive to changes in high cloudiness, are dominated by LW effects with an intraseasonal variation of ~0.4–0.6 K/d. While both the water vapor and cloud fields are inextricably linked, it appears that the tilted radiative structures are more related to water vapor effects. The intraseasonal variation of column-net radiative heating Q r enhances the convective signal in the mean by ~20% with a minimum in this enhancement ~10 days prior to peak MJO rainfall and maximum ~7 days after. Finally, this suggests that as MJO convective envelope weakens over the central IO, cloud-radiative feedbacks help maintain the mature MJO as it moves eastward.« less

  12. Predicting carbon dioxide and energy fluxes across global FLUXNET sites with regression algorithms

    DOE PAGES

    Tramontana, Gianluca; Jung, Martin; Schwalm, Christopher R.; ...

    2016-07-29

    Spatio-temporal fields of land–atmosphere fluxes derived from data-driven models can complement simulations by process-based land surface models. While a number of strategies for empirical models with eddy-covariance flux data have been applied, a systematic intercomparison of these methods has been missing so far. In this study, we performed a cross-validation experiment for predicting carbon dioxide, latent heat, sensible heat and net radiation fluxes across different ecosystem types with 11 machine learning (ML) methods from four different classes (kernel methods, neural networks, tree methods, and regression splines). We applied two complementary setups: (1) 8-day average fluxes based on remotely sensed data andmore » (2) daily mean fluxes based on meteorological data and a mean seasonal cycle of remotely sensed variables. The patterns of predictions from different ML and experimental setups were highly consistent. There were systematic differences in performance among the fluxes, with the following ascending order: net ecosystem exchange ( R 2 < 0.5), ecosystem respiration ( R 2 > 0.6), gross primary production ( R 2> 0.7), latent heat ( R 2 > 0.7), sensible heat ( R 2 > 0.7), and net radiation ( R 2 > 0.8). The ML methods predicted the across-site variability and the mean seasonal cycle of the observed fluxes very well ( R 2 > 0.7), while the 8-day deviations from the mean seasonal cycle were not well predicted ( R 2 < 0.5). Fluxes were better predicted at forested and temperate climate sites than at sites in extreme climates or less represented by training data (e.g., the tropics). Finally, the evaluated large ensemble of ML-based models will be the basis of new global flux products.« less

  13. Thermodynamic analysis of engineering solutions aimed at raising the efficiency of integrated gasification combined cycle

    NASA Astrophysics Data System (ADS)

    Gordeev, S. I.; Bogatova, T. F.; Ryzhkov, A. F.

    2017-11-01

    Raising the efficiency and environmental friendliness of electric power generation from coal is the aim of numerous research groups today. The traditional approach based on the steam power cycle has reached its efficiency limit, prompted by materials development and maneuverability performance. The rival approach based on the combined cycle is also drawing nearer to its efficiency limit. However, there is a reserve for efficiency increase of the integrated gasification combined cycle, which has the energy efficiency at the level of modern steam-turbine power units. The limit of increase in efficiency is the efficiency of NGCC. One of the main problems of the IGCC is higher costs of receiving and preparing fuel gas for GTU. It would be reasonable to decrease the necessary amount of fuel gas in the power unit to minimize the costs. The effect can be reached by raising of the heat value of fuel gas, its heat content and the heat content of cycle air. On the example of the process flowsheet of the IGCC with a power of 500 MW, running on Kuznetsk bituminous coal, by means of software Thermoflex, the influence of the developed technical solutions on the efficiency of the power plant is considered. It is received that rise in steam-air blast temperature to 900°C leads to an increase in conversion efficiency up to 84.2%. An increase in temperature levels of fuel gas clean-up to 900°C leads to an increase in the IGCC efficiency gross/net by 3.42%. Cycle air heating reduces the need for fuel gas by 40% and raises the IGCC efficiency gross/net by 0.85-1.22%. The offered solutions for IGCC allow to exceed net efficiency of analogous plants by 1.8-2.3%.

  14. Predicting carbon dioxide and energy fluxes across global FLUXNET sites with regression algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tramontana, Gianluca; Jung, Martin; Schwalm, Christopher R.

    Spatio-temporal fields of land–atmosphere fluxes derived from data-driven models can complement simulations by process-based land surface models. While a number of strategies for empirical models with eddy-covariance flux data have been applied, a systematic intercomparison of these methods has been missing so far. In this study, we performed a cross-validation experiment for predicting carbon dioxide, latent heat, sensible heat and net radiation fluxes across different ecosystem types with 11 machine learning (ML) methods from four different classes (kernel methods, neural networks, tree methods, and regression splines). We applied two complementary setups: (1) 8-day average fluxes based on remotely sensed data andmore » (2) daily mean fluxes based on meteorological data and a mean seasonal cycle of remotely sensed variables. The patterns of predictions from different ML and experimental setups were highly consistent. There were systematic differences in performance among the fluxes, with the following ascending order: net ecosystem exchange ( R 2 < 0.5), ecosystem respiration ( R 2 > 0.6), gross primary production ( R 2> 0.7), latent heat ( R 2 > 0.7), sensible heat ( R 2 > 0.7), and net radiation ( R 2 > 0.8). The ML methods predicted the across-site variability and the mean seasonal cycle of the observed fluxes very well ( R 2 > 0.7), while the 8-day deviations from the mean seasonal cycle were not well predicted ( R 2 < 0.5). Fluxes were better predicted at forested and temperate climate sites than at sites in extreme climates or less represented by training data (e.g., the tropics). Finally, the evaluated large ensemble of ML-based models will be the basis of new global flux products.« less

  15. Observations of Recent Arctic Sea Ice Volume Loss and Its Impact on Ocean-Atmosphere Energy Exchange and Ice Production

    NASA Technical Reports Server (NTRS)

    Kurtz, N. T.; Markus, T.; Farrell, S. L.; Worthen, D. L.; Boisvert, L. N.

    2011-01-01

    Using recently developed techniques we estimate snow and sea ice thickness distributions for the Arctic basin through the combination of freeboard data from the Ice, Cloud, and land Elevation Satellite (ICESat) and a snow depth model. These data are used with meteorological data and a thermodynamic sea ice model to calculate ocean-atmosphere heat exchange and ice volume production during the 2003-2008 fall and winter seasons. The calculated heat fluxes and ice growth rates are in agreement with previous observations over multiyear ice. In this study, we calculate heat fluxes and ice growth rates for the full distribution of ice thicknesses covering the Arctic basin and determine the impact of ice thickness change on the calculated values. Thinning of the sea ice is observed which greatly increases the 2005-2007 fall period ocean-atmosphere heat fluxes compared to those observed in 2003. Although there was also a decline in sea ice thickness for the winter periods, the winter time heat flux was found to be less impacted by the observed changes in ice thickness. A large increase in the net Arctic ocean-atmosphere heat output is also observed in the fall periods due to changes in the areal coverage of sea ice. The anomalously low sea ice coverage in 2007 led to a net ocean-atmosphere heat output approximately 3 times greater than was observed in previous years and suggests that sea ice losses are now playing a role in increasing surface air temperatures in the Arctic.

  16. An energy and mortality impact assessment of the urban heat island in the US

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowe, Scott A., E-mail: Scott.lowe@manhattan.edu

    Increased summer energy use and increased summer heat related mortality are the two most cited detrimental impacts of the urban heat island (UHI). An assessment of these impacts was made that considered the annual impact of the UHI, not just the summer impact. It was found that in north of the US there was a net decrease in energy use from the UHI, as heating energy reductions were larger than the increase in cooling energy. In the south there was a net energy increase from the UHI. The impact of the UHI on heat related deaths was an estimated increasemore » of 1.1 deaths per million people. The impact of the UHI on cold related deaths was an estimated decrease of 4.0 deaths per million people. These estimates are caveated by the acknowledgement that compounding factors influence mortality. Hypothermia related death rates were three times higher in rural areas than urban areas. This is surprising as the homeless population is usually considered the most at risk, yet they mostly live in urban areas. - Highlights: • The urban heat island (UHI) may actually be beneficial in colder cities in the US in terms of energy use • The UHI may cause an increase in heat related mortality of ~ 1 deaths per million • In winter the UHI may decrease cold related mortality by ~ 4 deaths per million • Cold related death rates were 3 times higher in rural areas although the homeless population live mainly in urban areas.« less

  17. Shooshanian Engineering Associates, Inc.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selig, M.A.

    1995-12-31

    A progress summary of the project, District Heating Network Extension under the Krakow Clean Fossil Fuels and Energy Efficiency is presented. The results of the project to data have shown a high degree of success. The primary objective of the project - to reduce air pollution in Krakow by eliminating coal-fired boiler plants and connecting them to the district heating network - is very much on the path to achievement. The emissions reduction goals for the project will be substantially exceeded by the end of the work. In addition to the above, a comprehensive series of training seminars in marketingmore » and customer service to the Marketing Department of MPEC was presented. These seminars, which were held in Boston and Krakow, were accompanied by detailed 400-page manual prepared in both English and Polish. The purpose of the training program was to assist MPEC in its long-term objectives of retaining existing customers and attracting new ones.« less

  18. Projected temperature-related deaths in ten large U.S. metropolitan areas under different climate change scenarios.

    PubMed

    Weinberger, Kate R; Haykin, Leah; Eliot, Melissa N; Schwartz, Joel D; Gasparrini, Antonio; Wellenius, Gregory A

    2017-10-01

    There is an established U-shaped association between daily temperature and mortality. Temperature changes projected through the end of century are expected to lead to higher rates of heat-related mortality but also lower rates of cold-related mortality, such that the net change in temperature-related mortality will depend on location. We quantified the change in heat-, cold-, and temperature-related mortality rates through the end of the century across 10 large US metropolitan areas. We applied location-specific projections of future temperature from over 40 downscaled climate models to exposure-response functions relating daily temperature and mortality in 10 US metropolitan areas to estimate the change in temperature-related mortality rates in 2045-2055 and 2085-2095 compared to 1992-2002, under two greenhouse gas emissions scenarios (RCP 4.5 and 8.5). We further calculated the total number of deaths attributable to temperature in 1997, 2050, and 2090 in each metropolitan area, either assuming constant population or accounting for projected population growth. In each of the 10 metropolitan areas, projected future temperatures were associated with lower rates of cold-related deaths and higher rates of heat-related deaths. Under the higher-emission RCP 8.5 scenario, 8 of the 10 metropolitan areas are projected to experience a net increase in annual temperature-related deaths per million people by 2086-2095, ranging from a net increase of 627 (95% empirical confidence interval [eCI]: 239, 1018) deaths per million in Los Angeles to a net decrease of 59 (95% eCI: -485, 314) deaths per million in Boston. Applying these projected temperature-related mortality rates to projected population size underscores the large public health burden of temperature. Increases in the heat-related death rate are projected to outweigh decreases in the cold-related death rate in 8 out of 10 cities studied under a high emissions scenario. Adhering to a lower greenhouse gas emissions scenario has the potential to substantially reduce future temperature-related mortality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. A novel stochastic modeling method to simulate cooling loads in residential districts

    DOE PAGES

    An, Jingjing; Yan, Da; Hong, Tianzhen; ...

    2017-09-04

    District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3)more » a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.« less

  20. A novel stochastic modeling method to simulate cooling loads in residential districts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    An, Jingjing; Yan, Da; Hong, Tianzhen

    District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3)more » a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.« less

  1. Interactions between Lakes and the Atmosphere over the Largest High-Altitude Saline Lake on the Qinghai-Tibet Plateau

    NASA Astrophysics Data System (ADS)

    Li, X.

    2017-12-01

    Interactions between lakes and the atmosphere at high-altitudes are still poorly understood due to difficulty in accessibility of direct measurements. This is particularly true for the Qinghai-Tibet Plateau (QTP), where approximately 50% of the lakes in China are located. Continuous direct measurements of the water flux and surface energy budget were made over the largest high-altitude saline lake in China, Qinghai Lake on the northeastern QTP, using the eddy covariance (EC) method from 11 May, 2013 through 10 May, 2015. Results indicated that net radiation and heat storage showed consistent diurnal variation with positive values in the daytime and negative values at night, while latent and sensible heat flux showed little diurnal variation. Nocturnal λE and H contributed to 47.7% and 29.0% of the total heat loss, during the two- year study period. Annual evaporation of Qinghai Lake was 832.5 mm for 2013/2014 and 823.6 mm for 2014/2015, respectively. The surface energy budget and evaporation showed a strong seasonal pattern, with peaks in the latent and sensible heat flux observed in autumn and early winter. There was a 2-3 month delay between the maximum net radiation and maximum latent and sensible heat fluxes. Intraseasonal and seasonal variations in latent and sensible heat flux were strongly affected by different air masses. Westerly cold and dry air masses increased evaporation while southeast moist air mass suppressed evaporation, suggesting that the lakes might serve as an 'air-conditioner' to modify the temporal heat and water flux in QTP. Latent heat flux (λE) during the ice-covered period was less than that during the ice-free period, and lake ice sublimation is perhaps a main possible source for λE during the freeze-up period.

  2. Comment on "Not all counterclockwise thermodynamic cycles are refrigerators" [Am. J. Phys. 84, 413-418 (2016)

    NASA Astrophysics Data System (ADS)

    Bizarro, João P. S.

    2017-11-01

    Contrary to what Dickerson and Mottmann [Am. J. Phys. 84, 413-418 (2016)] state, the temperatures at which a refrigerator's working fluid absorbs heat need not always lie below those at which it expels heat; nor must a refrigerator's thermodynamic cycle have two adiabats. Moreover, what Dickerson and Mottmann call a "comparison Carnot cycle" cannot always be defined. These conclusions are illustrated here using a counter-clockwise Stirling cycle without regeneration. A refrigerator's cold reservoir can absorb some heat and its hot reservoir can expel some heat, so long as the net heat flow is still out of the cold reservoir and into the hot reservoir.

  3. Effect of synthetic surfaces and vegetation in urban areas on human energy balance and comfort

    Treesearch

    Thomas F. Stark; David R. Miller

    1977-01-01

    The thermal balance of a standard man was quantified for a variety of urban and rural summer daytime microclimates. The resulting net heat-load data were correlated with the relative amounts of vegetation and synthetic materials at each site. By extrapolating these results, it is possible to estimate the expected heat load of a proposed development before it is built...

  4. Forest canopy temperatures: dynamics, controls, and relationships with ecosystem fluxes

    NASA Astrophysics Data System (ADS)

    Still, C. J.; Griffith, D.; Kim, Y.; Law, B. E.; Hanson, C. V.; Kwon, H.; Schulze, M.; Detto, M.; Pau, S.

    2017-12-01

    Temperature strongly affects enzymatic reactions, ecosystem biogeochemistry, and species distributions. Although most focus is on air temperature, the radiative or skin temperature of plants is more relevant. Canopy skin temperature dynamics reflect biophysical, physiological, and anatomical characteristics and interactions with the environment, and can be used to examine forest responses to stresses like droughts and heat waves. Thermal infrared (TIR) imaging allows for extensive temporal and spatial sampling of canopy temperatures, particularly compared to spot measurements using thermocouples. We present results of TIR imaging of forest canopies at eddy covariance flux tower sites in the US Pacific Northwest and in Panama. These forests range from an old-growth temperate rainforest to a second growth semi-arid pine forest to a semi-deciduous tropical forest. Canopy temperature regimes at these sites are highly variable. Canopy temperatures at all forest sites displayed frequent departures from air temperature, particularly during clear sky conditions, with elevated canopy temperatures during the day and depressed canopy temperatures at night compared to air temperature. Comparison of canopy temperatures to fluxes of carbon dioxide, water vapor, and energy reveals stronger relationships than those found with air temperature. Daytime growing season net ecosystem exchange at the pine forest site is better explained by canopy temperature (r2 = 0.61) than air temperature (r2 = 0.52). At the semi-deciduous tropical forest, canopy photosynthesis is highly correlated with canopy temperature (r2 = 0.51), with a distinct optimum temperature for photosynthesis ( 31 °C) that agrees with leaf-level measurements. During the peak of one heat wave at an old-growth temperate rainforest, hourly averaged air temperature exceeded 35 °C, 10 °C above average. Peak hourly canopy temperature approached 40 °C, and leaf-to-air vapor pressure deficit exceeded 6 kPa. These extreme conditions had a dramatic effect on forest carbon and energy exchanges: the canopy switched from daytime net carbon uptake prior to the heatwave to net carbon release during and immediately after the heat wave. The latent heat flux from evapotranspiration increased during the heat wave, while sensible heat fluxes were lower.

  5. What do the CERES Product Levels represent?

    Atmospheric Science Data Center

    2014-12-08

    ... Products Level 1B Data products are processed to sensor units. The BDS product contains CERES ... between average global net TOA flux imbalance and ocean heat storage). EBAF   CERES: Product Questions ...

  6. Geothermal energy

    NASA Astrophysics Data System (ADS)

    Manzella, A.

    2015-08-01

    Geothermal technologies use renewable energy resources to generate electricity and direct use of heat while producing very low levels of greenhouse-gas (GHG) emissions. Geothermal energy is stored in rocks and in fluids circulating in the underground. Electricity generation usually requires geothermal resources temperatures of over 100°C. For heating, geothermal resources spanning a wider range of temperatures can be used in applications such as space and district heating (and cooling, with proper technology), spa and swimming pool heating, greenhouse and soil heating, aquaculture pond heating, industrial process heating and snow melting. Geothermal technology, which has focused so far on extracting naturally heated steam or hot water from natural hydrothermal reservoirs, is developing to more advanced techniques to exploit the heat also where underground fluids are scarce and to use the Earth as a potential energy battery, by storing heat. The success of the research will enable energy recovery and utilization from a much larger fraction of the accessible thermal energy in the Earth's crust.

  7. Association Between State Assistance on the Topic of Indoor Air Quality and School District-Level Policies That Promote Indoor Air Quality in Schools.

    PubMed

    Everett Jones, Sherry; Doroski, Brenda; Glick, Sherry

    2015-12-01

    Nationally representative data from the 2012 School Health Policies and Practices Study examined whether state assistance on indoor air quality (IAQ) was associated with district-level policies and practices related to IAQ and integrated pest management (IPM). Districts in states that provided assistance on IAQ were more likely than districts not in such states to (1) have an IAQ management program (p < .001); (2) require schools to conduct periodic inspections of the heating, ventilation, and air conditioning system (p < .05); of the building for cracks, leaks, or past water damage (p < .01); for mold (p < .01); for clutter that prevents effective cleaning and maintenance (p < .05); of the plumbing system (p < .01); and for condensation in and around school facilities (p < .001); (3) have an engine idling reduction program ( < .001); (4) have a policy to purchase low-emitting products (p < .05); and (5) require IPM strategies (p < .05). Increasing the number of states that provide IAQ-related assistance to school districts and schools may improve school IAQ. © The Author(s) 2015.

  8. Analyzing the carbon dynamics in north western Portugal: calibration and application of Forest-BGC

    NASA Astrophysics Data System (ADS)

    Rodrigues, M. A.; Lopes, D. M.; Leite, S. M.; Tabuada, V. M.

    2010-04-01

    Net primary production (NPP) is an important variable that allows monitoring forestry ecosystems fixation of atmospheric Carbon. The importance of monitoring the sequestred carbon is related to the binding commitments established by the Kyoto Protocol. There are ecophysiologic models, as Forest-BGC that allow for estimating NPP. In a first stage, this study aims to analyze the climate evolution at the Vila Real administrative district during the last decades. The historical information will be observed in order to detect the past tendencies of evolution. Past will help us to predict future. In a next stage these tendencies will be used to infer the impact of these change scenarios on the net primary production of the forest ecosystems from this study area. For a parameterization and validation of the FOREST-BGC, this study was carried on based on 500 m2 sampling plots from the National Forest Inventory 2006 and are located in several County Halls of the district of Vila Real (Montalegre, Chaves, Valpaços, Boticas, Vila Pouca de Aguiar, Murça, Mondim de Basto, Alijó, Sabrosa and Vila Real). In order to quantify Biomass dinamics, we have selected 45 sampling plots: 19 from Pinus pinaster stands, 17 from Quercus pyrenaica and 10 from mixed of Quercus pyrenaica with Pinus pinaster. Adaptation strategies for climate change impacts can be proposed based on these research results.

  9. Identification and stocking density of elements phosphate indigo system for fish farming cages nets floating in freshwater district Laut Tawar, Aceh Province

    NASA Astrophysics Data System (ADS)

    Eriyusni, N.; Siregar, A. Z.

    2018-02-01

    Lake Laut Tawar is located in Aceh district of Aceh province. The lake were used by the community as a livelihood by making a Cages. One of the elements that influence the fish growth is an element Phosphate (PO4) and other such as, pH, nitrate-nitrite, temperature and others. The lake has undergone changes caused by the use of commercial feed. The sampling locations based on the environmental setting by using method "purposive sampling" from January to May. The results was found of 0.1407 mg/L phosphate with fish expenditure amounting to 23728.61 ton / year using cages of net with number as 92, stocking density at 48,950 of fish and marine area 19.77 Ha. However the standard classes showed is under class II Regulation with No. 82 Year 2001 3400, solid lowest stocking cages tail on the size of 2.5 x 2.5 x 3M (spacious, 181m3) with post-harvest fish expenditure amounted to 1,214 tons of fish/year, the highest 9,250 cages tail on the size e of 5 x 5 x 3m (spacious 123m3) with fish expenditure by 2,800 tones of fish/year. While the results of feed conversion and Phosphate content is 12.70% with the Feed Conversion Ratio (FCR) was 1,635 and 1,491.

  10. 7 CFR 51.1565 - Internal defects.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., Internal Discoloration, Vascular Browning, Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5... Discoloration (Heat Necrosis) Not more than the equivalent of 3 scattered spots 1/8 inch in diameter in a potato...

  11. 7 CFR 51.1565 - Internal defects.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., Internal Discoloration, Vascular Browning, Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5... Discoloration (Heat Necrosis) Not more than the equivalent of 3 scattered spots 1/8 inch in diameter in a potato...

  12. Non-linear lumped model circuit of capacitively coupled plasmas at the intermediate radio-frequencies

    NASA Astrophysics Data System (ADS)

    Shihab, Mohammed

    2018-06-01

    The discharge dynamics in geometrically asymmetric capacitively coupled plasmas are investigated via a lumped model circuit. A realistic reactor configuration is assumed. A single and two separate RF voltage sources are considered. One of the driven frequencies (the higher frequency) has been adjusted to excite a plasma series resonance, while the second frequency (the lower frequency) is in the range of the ion plasma frequency. Increasing the plasma pressure in the low pressure regime (≤ 100mTorr) is found to diminish the amplitude of the self-excited harmonics of the discharge current, however, the net result is enhancing the plasma heating. The modulation of the ion density with the lower driving frequency affect the plasma heating considerably. The net effect depends on the amplitude and the phase of the ion modulation.

  13. Reuse of heat energy in wastewater: implementation examples in Japan.

    PubMed

    Funamizu, N; Iida, M; Sakakura, Y; Takakuwa, T

    2001-01-01

    Sewage and treated water can be a heat source in urban area due to large heat capacity, thus recovery and reuse of its energy is one of the most desirable plans for the sewerage system. In this paper, characteristics of heat energy in wastewater, reuse plans, and some experiences in Japan are presented. Full-scale reuse projects for heating and cooling in the Tokyo Metropolitan Districts and project for melting snow in Sapporo City are discussed. The key factors found in experience of Tokyo were setting the heat pumps near the demand points and the technical developments of equipment to prevent system from clogging, corrosion, and decrease in the heat transfer efficiency. It was also found through the project for melting snow in Sapporo that the key factor in public acceptance was the multi-purpose use of the sewerage system both for melting snow in winter and retaining rain water in summer.

  14. Simulating Crop Evapotranspiration Response under Different Planting Scenarios by Modified SWAT Model in an Irrigation District, Northwest China.

    PubMed

    Liu, Xin; Wang, Sufen; Xue, Han; Singh, Vijay P

    2015-01-01

    Modelling crop evapotranspiration (ET) response to different planting scenarios in an irrigation district plays a significant role in optimizing crop planting patterns, resolving agricultural water scarcity and facilitating the sustainable use of water resources. In this study, the SWAT model was improved by transforming the evapotranspiration module. Then, the improved model was applied in Qingyuan Irrigation District of northwest China as a case study. Land use, soil, meteorology, irrigation scheduling and crop coefficient were considered as input data, and the irrigation district was divided into subdivisions based on the DEM and local canal systems. On the basis of model calibration and verification, the improved model showed better simulation efficiency than did the original model. Therefore, the improved model was used to simulate the crop evapotranspiration response under different planting scenarios in the irrigation district. Results indicated that crop evapotranspiration decreased by 2.94% and 6.01% under the scenarios of reducing the planting proportion of spring wheat (scenario 1) and summer maize (scenario 2) by keeping the total cultivated area unchanged. However, the total net output values presented an opposite trend under different scenarios. The values decreased by 3.28% under scenario 1, while it increased by 7.79% under scenario 2, compared with the current situation. This study presents a novel method to estimate crop evapotranspiration response under different planting scenarios using the SWAT model, and makes recommendations for strategic agricultural water management planning for the rational utilization of water resources and development of local economy by studying the impact of planting scenario changes on crop evapotranspiration and output values in the irrigation district of northwest China.

  15. Simulating Crop Evapotranspiration Response under Different Planting Scenarios by Modified SWAT Model in an Irrigation District, Northwest China

    PubMed Central

    Liu, Xin; Wang, Sufen; Xue, Han; Singh, Vijay P.

    2015-01-01

    Modelling crop evapotranspiration (ET) response to different planting scenarios in an irrigation district plays a significant role in optimizing crop planting patterns, resolving agricultural water scarcity and facilitating the sustainable use of water resources. In this study, the SWAT model was improved by transforming the evapotranspiration module. Then, the improved model was applied in Qingyuan Irrigation District of northwest China as a case study. Land use, soil, meteorology, irrigation scheduling and crop coefficient were considered as input data, and the irrigation district was divided into subdivisions based on the DEM and local canal systems. On the basis of model calibration and verification, the improved model showed better simulation efficiency than did the original model. Therefore, the improved model was used to simulate the crop evapotranspiration response under different planting scenarios in the irrigation district. Results indicated that crop evapotranspiration decreased by 2.94% and 6.01% under the scenarios of reducing the planting proportion of spring wheat (scenario 1) and summer maize (scenario 2) by keeping the total cultivated area unchanged. However, the total net output values presented an opposite trend under different scenarios. The values decreased by 3.28% under scenario 1, while it increased by 7.79% under scenario 2, compared with the current situation. This study presents a novel method to estimate crop evapotranspiration response under different planting scenarios using the SWAT model, and makes recommendations for strategic agricultural water management planning for the rational utilization of water resources and development of local economy by studying the impact of planting scenario changes on crop evapotranspiration and output values in the irrigation district of northwest China. PMID:26439928

  16. Mathematical simulation and optimization of cutting mode in turning of workpieces made of nickel-based heat-resistant alloy

    NASA Astrophysics Data System (ADS)

    Bogoljubova, M. N.; Afonasov, A. I.; Kozlov, B. N.; Shavdurov, D. E.

    2018-05-01

    A predictive simulation technique of optimal cutting modes in the turning of workpieces made of nickel-based heat-resistant alloys, different from the well-known ones, is proposed. The impact of various factors on the cutting process with the purpose of determining optimal parameters of machining in concordance with certain effectiveness criteria is analyzed in the paper. A mathematical model of optimization, algorithms and computer programmes, visual graphical forms reflecting dependences of the effectiveness criteria – productivity, net cost, and tool life on parameters of the technological process - have been worked out. A nonlinear model for multidimensional functions, “solution of the equation with multiple unknowns”, “a coordinate descent method” and heuristic algorithms are accepted to solve the problem of optimization of cutting mode parameters. Research shows that in machining of workpieces made from heat-resistant alloy AISI N07263, the highest possible productivity will be achieved with the following parameters: cutting speed v = 22.1 m/min., feed rate s=0.26 mm/rev; tool life T = 18 min.; net cost – 2.45 per hour.

  17. Reports of long-lasting insecticidal bed nets catching on fire: a threat to bed net users and to successful malaria control?

    PubMed Central

    2014-01-01

    Background One of the control tools to reduce malaria transmission is the use of LLINs. However, several studies show that household bed net use is quite low. A study was developed to better understand the cultural factors that might explain these gaps in Benin. One reason mentioned is that bed nets can catch on fire and cause harm. This paper presents a summary of these findings, their analysis and the ensuing issues. Methods This anthropological study is based on an inductive qualitative approach, including 91 semi-structured interviews conducted from July 2011 to March 2012 in a health district in Southern Benin. Results Fifty-six persons stated that bed nets can catch on fire but do not always refer to specific facts. However, 34 of the 56 people narrate specific events they heard or experienced. 39 accounts were geographically located and situated in time, with various details. In 27 situations, people were burned, for which 12 people reportedly died. Discussion The disparity between these results and the dearth of bibliographic documentation in the initial search prompted a more in-depth literature review: 16 contributions between 1994 and 2013 were found. Bed net fires were noted in 10 countries, but it is impossible to ascertain the frequency of such events. Moreover, bodily harm can be significant, and several cases of death attributed to bed net fires were noted. Conclusions Indisputably, the use of bed nets to reduce the impact of this terrible disease is an optimal control method. However, the perception that LLINs have a potentially negative effect hinders the use rate in the real world, at least for some. If some people fear the risk of fires, this possibility must be addressed during information and prevention sessions on malaria, with a communication strategy tailored to specific social contexts. Moreover, all possible measures should be taken to limit the harm suffered by individuals and their families. PMID:24972637

  18. Heat sink effects on weld bead: VPPA process

    NASA Technical Reports Server (NTRS)

    Steranka, Paul O., Jr.

    1990-01-01

    An investigation into the heat sink effects due to weldment irregularities and fixtures used in the variable polarity plasma arc (VPPA) process was conducted. A basic two-dimensional model was created to represent the net heat sink effect of surplus material using Duhamel's theorem to superpose the effects of an infinite number of line heat sinks of variable strength. Parameters were identified that influence the importance of heat sink effects. A characteristic length, proportional to the thermal diffusivity of the weldment material divided by the weld torch travel rate, correlated with heat sinking observations. Four tests were performed on 2219-T87 aluminum plates to which blocks of excess material were mounted in order to demonstrate heat sink effects. Although the basic model overpredicted these effects, it correctly indicated the trends shown in the experimental study and is judged worth further refinement.

  19. Heat sink effects on weld bead: VPPA process

    NASA Technical Reports Server (NTRS)

    Steranka, Paul O., Jr.

    1989-01-01

    An investigation into the heat sink effects due to weldment irregularities and fixtures used in the variable polarity plasma arc (VPPA) process was conducted. A basic two-dimensional model was created to represent the net heat sink effect of surplus material using Duhamel's theorem to superpose the effects of an infinite number of line heat sinks of variable strength. Parameters were identified that influence the importance of heat sink effects. A characteristic length, proportional to the thermal diffusivity of the weldment material divided by the weld torch travel rate, correlated with heat sinking observations. Four tests were performed on 2219-T87 aluminum plates to which blocks of excess material were mounted in order to demonstrate heat sink effects. Although the basic model overpredicted these effects, it correctly indicated the trends shown in the experimental study and is judged worth further refinement.

  20. Municipal solid waste incineration plant: A multi-step approach to the evaluation of an energy-recovery configuration.

    PubMed

    Panepinto, D; Zanetti, M C

    2018-03-01

    This study proposes a multi-step approach to evaluating the environmental and economic aspects of a thermal treatment plant with an energy-recovery configuration. In order to validate the proposed approach, the Turin incineration plant was analyzed, and the potential of the incinerator and several different possible connections to the district heating network were then considered. Both local and global environmental balances were defined. The global-scale results provided information on carbon dioxide emissions, while the local-scale results were used as reference values for the implementation of a Gaussian model that could evaluate the actual concentrations of pollutants released into the atmosphere. The economic aspects were then analyzed, and a correspondence between the environmental and economic advantages defined. The results showed a high energy efficiency for the combined production of heat and electricity, and the opportunity to minimize environmental impacts by including cogeneration in a district heating scheme. This scheme showed an environmental advantage, whereas the electricity-only configuration showed an economic advantage. A change in the thermal energy price (specifically, to 40 €/MWh), however, would make it possible to obtain both environmental and economic advantages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Solar heating for an observatory--Lincoln, Nebraska

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Report describes solar-energy system for 50 seat observatory that provides 60 percent of space heating needs. System includes 9 flat-plate collectors, rock storage bin, blowers, controls, ducting, and auxiliary natural-gas furnace; it has five operation modes. Net energy savings were 11.31 million Btu for 12 months, or equivalent of 1.9 barrels of oil. Report appendixes list performance factor definitions, performance equations, and average area weather conditions.

  2. Industry - Military Energy Symposium, held 21-23 October 1980, San Antonio, Texas

    DTIC Science & Technology

    1980-10-21

    unless the best available technology is applied to many sources including those the size of airports . Further discussion of these issues will hopefully...particularly with naphthenic fuels. A similar weakness applies to correlations of net heat of combustion. Some additional correlating parameters...Viscosity Boost pump power Line size and weight Thermal Stability Gum, deposits, nozzle coking Specific Heat Avionics and engine oil cooling Aromatics

  3. Best Practices Case Study: CDC Realty, Inc. - Centennial Terrace, Tucson, AZ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-10-01

    Case study on CDC Realty who achieved HERS 70 by putting ducts in a conditioned attic insulated along the roofline with netted cellulose, R-5 rigid insulated sheathing over R-19 wall cavity insulation, and deep overhangs and low-e windows to minimize solar heat gain. The 17 homes are solar-ready for solar water heating and five have integral collector storage hot water systems on the roof.

  4. Development of a self contained heat rejection module, phase 2 and 3

    NASA Technical Reports Server (NTRS)

    Fleming, M. L.

    1976-01-01

    The fabrication and testing of a prototype deployable radiator system is described. Vapor compression with a conventional aircraft compressor yielded a net heat rejection effect at high environments while returning low temperature (10 F and 35 F) conditioned fluid to the payload thermal control system. The system is compatible with shuttle orbiter payloads, free flying experiment modules launched from the shuttle, or by another launch vehicle.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. Aldrich and J. Williamson

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2.) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support form the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aldrich, Robb; Williamson, James

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: 1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads; 2) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes; 3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating; and 4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less

  8. Validation of a program for supercritical power plant calculations

    NASA Astrophysics Data System (ADS)

    Kotowicz, Janusz; Łukowicz, Henryk; Bartela, Łukasz; Michalski, Sebastian

    2011-12-01

    This article describes the validation of a supercritical steam cycle. The cycle model was created with the commercial program GateCycle and validated using in-house code of the Institute of Power Engineering and Turbomachinery. The Institute's in-house code has been used extensively for industrial power plants calculations with good results. In the first step of the validation process, assumptions were made about the live steam temperature and pressure, net power, characteristic quantities for high- and low-pressure regenerative heat exchangers and pressure losses in heat exchangers. These assumptions were then used to develop a steam cycle model in Gate-Cycle and a model based on the code developed in-house at the Institute of Power Engineering and Turbomachinery. Properties, such as thermodynamic parameters at characteristic points of the steam cycle, net power values and efficiencies, heat provided to the steam cycle and heat taken from the steam cycle, were compared. The last step of the analysis was calculation of relative errors of compared values. The method used for relative error calculations is presented in the paper. The assigned relative errors are very slight, generally not exceeding 0.1%. Based on our analysis, it can be concluded that using the GateCycle software for calculations of supercritical power plants is possible.

  9. Geothermal energy systems plan for Boise City

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-01-01

    This is a plan for development of a downtown Boise geothermal district space heating system incorporating legal, engineering, organizational, geological, and economic requirements. Topics covered include: resource characteristics, system design and feasibility, economic feasibility, legal overview, organizational alternatives, and conservation. Included in appendices are: property ownership patterns on the Boise Front, existing hot well data, legal briefs, environmental data, decision point communications, typical building heating system retrofit schematics, and background assumptions and data for cost summary. (MHR)

  10. Building Modelling Methodologies for Virtual District Heating and Cooling Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saurav, Kumar; Choudhury, Anamitra R.; Chandan, Vikas

    District heating and cooling systems (DHC) are a proven energy solution that has been deployed for many years in a growing number of urban areas worldwide. They comprise a variety of technologies that seek to develop synergies between the production and supply of heat, cooling, domestic hot water and electricity. Although the benefits of DHC systems are significant and have been widely acclaimed, yet the full potential of modern DHC systems remains largely untapped. There are several opportunities for development of energy efficient DHC systems, which will enable the effective exploitation of alternative renewable resources, waste heat recovery, etc., inmore » order to increase the overall efficiency and facilitate the transition towards the next generation of DHC systems. This motivated the need for modelling these complex systems. Large-scale modelling of DHC-networks is challenging, as it has several components interacting with each other. In this paper we present two building methodologies to model the consumer buildings. These models will be further integrated with network model and the control system layer to create a virtual test bed for the entire DHC system. The model is validated using data collected from a real life DHC system located at Lulea, a city on the coast of northern Sweden. The test bed will be then used for simulating various test cases such as peak energy reduction, overall demand reduction etc.« less

  11. 19. INTERIOR, 'CHILLER NO. 2' (G.S.A. PHOTOCOPY, N.D.) (4 x ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. INTERIOR, 'CHILLER NO. 2' (G.S.A. PHOTOCOPY, N.D.) (4 x 5 NEGATIVE) - U.S. General Services Administration, Central Heating Plant, C & D Streets between Twelfth & Thirteenth Streets Southwest, Washington, District of Columbia, DC

  12. Integrating preconcentrator heat controller

    DOEpatents

    Bouchier, Francis A.; Arakaki, Lester H.; Varley, Eric S.

    2007-10-16

    A method and apparatus for controlling the electric resistance heating of a metallic chemical preconcentrator screen, for example, used in portable trace explosives detectors. The length of the heating time-period is automatically adjusted to compensate for any changes in the voltage driving the heating current across the screen, for example, due to gradual discharge or aging of a battery. The total deposited energy in the screen is proportional to the integral over time of the square of the voltage drop across the screen. Since the net temperature rise, .DELTA.T.sub.s, of the screen, from beginning to end of the heating pulse, is proportional to the total amount of heat energy deposited in the screen during the heating pulse, then this integral can be calculated in real-time and used to terminate the heating current when a pre-set target value has been reached; thereby providing a consistent and reliable screen temperature rise, .DELTA.T.sub.s, from pulse-to-pulse.

  13. Spatial Patterns of Heat-Related Cardiovascular Mortality in the Czech Republic

    PubMed Central

    Urban, Aleš; Burkart, Katrin; Kyselý, Jan; Schuster, Christian; Plavcová, Eva; Hanzlíková, Hana; Štěpánek, Petr; Lakes, Tobia

    2016-01-01

    The study examines spatial patterns of effects of high temperature extremes on cardiovascular mortality in the Czech Republic at a district level during 1994–2009. Daily baseline mortality for each district was determined using a single location-stratified generalized additive model. Mean relative deviations of mortality from the baseline were calculated on days exceeding the 90th percentile of mean daily temperature in summer, and they were correlated with selected demographic, socioeconomic, and physical-environmental variables for the districts. Groups of districts with similar characteristics were identified according to socioeconomic status and urbanization level in order to provide a more general picture than possible on the district level. We evaluated lagged patterns of excess mortality after hot spell occurrences in: (i) urban areas vs. predominantly rural areas; and (ii) regions with different overall socioeconomic level. Our findings suggest that climatic conditions, altitude, and urbanization generally affect the spatial distribution of districts with the highest excess cardiovascular mortality, while socioeconomic status did not show a significant effect in the analysis across the Czech Republic as a whole. Only within deprived populations, socioeconomic status played a relevant role as well. After taking into account lagged effects of temperature on excess mortality, we found that the effect of hot spells was significant in highly urbanized regions, while most excess deaths in rural districts may be attributed to harvesting effects. PMID:26959044

  14. Method for Fabricating Composite Structures Using Pultrusion Processing

    NASA Technical Reports Server (NTRS)

    Farley, Gary L. (Inventor)

    2000-01-01

    A method for fabricating composite structures at a low-cost, moderate-to-high production rate. A first embodiment of the method includes employing a continuous press forming fabrication process. A second embodiment of the method includes employing a pultrusion process for obtaining composite structures. The methods include coating yarns with matrix material, weaving the yarn into fabric to produce a continuous fabric supply and feeding multiple layers of net-shaped fabrics having optimally oriented fibers into a debulking tool to form an undebulked preform. The continuous press forming fabrication process includes partially debulking the preform, cutting the partially debulked preform and debulking the partially debulked preform to form a net-shape. An electron-beam or similar technique then cures the structure. The pultrusion fabric process includes feeding the undebulked preform into a heated die and gradually debulking the undebulked preform. The undebulked preform in the heated die changes dimension until a desired cross-sectional dimension is achieved. This process further includes obtaining a net-shaped infiltrated uncured preform, cutting the uncured preform to a desired length and electron-beam curing (or similar technique) the uncured preform. These fabrication methods produce superior structures formed at higher production rates, resulting in lower cost and high structural performance.

  15. Method for Fabricating Composite Structures Using Continuous Press Forming

    NASA Technical Reports Server (NTRS)

    Farley, Gary L. (Inventor)

    1997-01-01

    A method for fabricating composite structures at a low-cost. moderate-to-high production rate. A first embodiment of the method includes employing a continuous press forming fabrication process. A second embodiment of the method includes employing a pultrusion process for obtaining composite structures. The methods include coating yarns with matrix material, weaving the yarn into fabric to produce a continuous fabric supply and feeding multiple layers of net-shaped fabrics having optimally oriented fibers into a debulking tool to form an undebulked preform. The continuous press forming fabrication process includes partially debulking the preform, cutting the partially debulked preform and debulking the partially debulked preform to form a net-shape. An electron-beam or similar technique then cures the structure. The pultrusion fabric process includes feeding the undebulked preform into a heated die and gradually debulking the undebulked preform. The undebulked preform in the heated die changes dimension until a desired cross-sectional dimension is achieved. This process further includes obtaining a net-shaped infiltrated uncured preform, cutting the uncured preform to a desired length and electron-beam curing (or similar technique) the uncured preform. These fabrication methods produce superior structures formed at higher production rates. resulting in lower cost and high structural performance.

  16. The impact of boundary layer turbulence on snow growth and precipitation: Idealized Large Eddy Simulations

    NASA Astrophysics Data System (ADS)

    Chu, Xia; Xue, Lulin; Geerts, Bart; Kosović, Branko

    2018-05-01

    Ice particles and supercooled droplets often co-exist in planetary boundary-layer (PBL) clouds. The question examined in this numerical study is how large turbulent PBL eddies affect snow growth and surface precipitation from mixed-phase PBL clouds. In order to simplify this question, this study assumes an idealized BL with well-developed turbulence but no surface heat fluxes or radiative heat exchanges. Large Eddy Simulations with and without resolved PBL turbulence are compared. This comparison demonstrates that the impact on snow growth in mixed-phase clouds is controlled by two opposing mechanisms, a microphysical and a dynamical one. The cloud microphysical impact of large turbulent eddies is based on the difference in saturation vapor pressure over water and over ice. The net outcome of alternating turbulent up- and downdrafts is snow growth by diffusion and/or accretion (riming). On the other hand, turbulence-induced entrainment and detrainment may suppress snow growth. In the case presented herein, the net effect of these microphysical and dynamical processes is positive, but in general the net effect depends on ambient conditions, in particular the profiles of temperature, humidity, and wind.

  17. Heat Exchange Processes and Thermal Dynamics of a Glacier-Fed Stream

    NASA Astrophysics Data System (ADS)

    Khamis, K.; Hannah, D. M.; Brown, L. E.; Milner, A. M.

    2012-12-01

    Glacier-fed river thermal regimes vary markedly in space and time. However, knowledge is limited of fundamental processes controlling alpine stream temperature dynamics. The few studies have not sufficiently characterised above-stream micro-climate and have been limited to single melt seasons. To address the research gap, this study quantified heat exchanges at the water surface and bed of a glacier fed stream over two summers to improve understanding of factors and processes driving thermal dynamics. An automatic weather station and river gauge were set up on a stream 1.5 km from the Taillon Glacier, French Pyrénées. Hydro-meteorological observations were recorded at 15-min intervals between 16 June-2 September 2010 and 2011. Energy balance components were measured [net radiation (Q*); bed heat flux (Qbhf)] or estimated based on site-specific data [sensible heat transfer (Qh); latent heat (Qe); fluid friction (Qf)]. During 2010, snowline altitude was lower and glacier ablation occurred in late season. During 2010, the mean snowline altitude was lower and ablation of glacier ice occurred later in the season Mean water temperature was lower (-0.8°C), precipitation greater (+87mm) and daily discharge variation lower (-0.03 m3s-1) than 2011. The net heat budget was strongly positive in both summers, with the majority of energy exchanged at the air-water interface. Averaged over the seasons, Q* was the largest heat source (~80% of total flux); Qh (~13%) and Qf (~3%) were also sources. Qe displayed inter-annual variability; during 2010 (2011) it contributed 5.2% (0.03%) of the total heat budget due to windier, drier conditions that offset early season condensation gains with late season evaporative losses. Energy exchanges at the channel - river bed interface comprised <1% of the heat budget; Qbhf was a sink (source) during 2010 (2011). Daily flux totals were used to characterize sub-seasonal dynamics. Declines in net radiation receipt and total energy available to heat the water column were observed over the season due to shorter days. Qh and Qbhf displayed no sub-seasonal patterns, responding to prevailing hydro-meteorological conditions. Latent heat showed a shift from source to sink over the season, possibly linked to retreating snowline which changed microclimate and, in turn, temperature and humidity gradients. A deterministic energy balance model was used to simulate water column temperature. Maximum daily water temperatures were predicted with a RMSE of 1.44°C during 2011. Model performance was reduced in 2010 and early season water temperature overestimated systematically due to cold water inflows from valley snowpacks. These findings represent the first, inter-annual study of the heat exchange processes operating in a glacier fed river. Initial (un-calibrated) model performance suggests that process-based models represent useful tools for predicting future changes in alpine stream temperature. However, further work is needed to incorporate changing snow/ ice melt contributions as well as climate.

  18. 7 CFR 51.3416 - Classification of defects.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5% waste 10% waste. Occurring entirely... discoloration (Heat Necrosis) Not more than the equivalent of 3 scattered spots 1/8 inch in diameter in a potato...

  19. 7 CFR 51.3416 - Classification of defects.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., Fusarium Wilt, Net Necrosis, Other Necrosis, Stem End Browning 5% waste 10% waste. Occurring entirely... discoloration (Heat Necrosis) Not more than the equivalent of 3 scattered spots 1/8 inch in diameter in a potato...

  20. Air-sea interaction over the Indian Ocean due to variations in the Indonesian throughflow

    NASA Astrophysics Data System (ADS)

    Wajsowicz, R. C.

    The effects of the Indonesian throughflow on the upper thermocline circulation and surface heat flux over the Indian Ocean are presented for a 3-D ocean model forced by two different monthly wind-stress climatologies, as they show interesting differences, which could have implications for long-term variability in the Indian and Australasian monsoons. The effects are determined by contrasting a control run with a run in which the throughflow is blocked by an artificial land-bridge across the exit channels into the Indian Ocean. In the model forced by ECMWF wind stresses, there is little impact on the annual mean surface heat flux in the region surrounding the throughflow exit straits, whereas in the model forced by SSM/I-based wind stresses, a modest throughflow of less than 5 ×106 m3s-1 over the upper 300 m induces an extra 10-50 Wm-2 output. In the SSM/I-forced model, there is insignificant penetration of the throughflow into the northern Indian Ocean. However, in the ECMWF-forced model, the throughflow induces a 5-10 Wm-2 reduction in heat input into the ocean, i.e., an effective output, over the Somali Current in the annual mean. These differences are attributed to differences in the strength and direction of the Ekman transport of the ambient flow, and the vertical structure of the transport and temperature anomalies associated with the throughflow. In both models, the throughflow induces a 5-30 Wm-2 increase in net output over a broad swathe of the southern Indian Ocean, and a reduction in heat output of 10-60 Wm-2 in a large L-shaped band around Tasmania. Effective increases in throughflow-induced net output reach up to 40 (60) Wm-2 over the Agulhas Current retroflection in the ECMWF (SSM/I)-forced model. Seasonal variations in the throughflow's effect on the net surface heat flux are attributed to seasonal variations in the ambient circulation of the Indian Ocean, specifically in coastal upwelling along the south Javan, west Australian, and Somalian coasts, and in the depth of convective overturning between 40°S to 50°S, and its sensing of the mean throughflow's thermal anomaly. The seasonal anomalies plus annual mean yield maximum values for the throughflow-induced net surface heat output in boreal summer. Values may exceed 40 Wm-2 in the southern Indian Ocean interior in both models, exceed 60 Wm-2 over the Agulhas retroflection and immediate vicinity of the exit channels in the SSM/I-forced model, and reach 30 Wm-2 over the Somali jet in the ECMWF-forced model.

Top