The History and Challenges of Blood Donor Screening in China.
Li, Ling; Li, Ka Yi; Yan, Ke; Ou, Guojin; Li, Wenhui; Wang, Jue; Song, Ning; Tian, Li; Ji, Xin; Chen, Yongjun; Liang, Xiaohua; Liu, Zhong; Wu, Yanyun
2017-04-01
Since the establishment of People's Republic of China in 1949, the Chinese government has encountered several catastrophes related to transfusion transmitted diseases. The government's increasing attention to blood safety has prompted the initiation of a series of policies and measures that have enhanced the level of safety for the blood supply and met the basic clinical demands of blood for 1.3 billion people in the country. Blood donation screening strategies in China predominantly comprise donor screening and donor testing. Donor screening includes selection of low-risk blood donors by the use of a donor history questionnaire, predonation physical examination, and initial rapid donor testing. Donor testing includes direct pathogen detection and serology tests. The year 1998 marked the most transformative change in blood donor selection and screening policies in China. Before 1998, paid donation was the predominant mode of blood donation. Donor screening and donor testing were conducted before donation, and only those who were eligible were allowed to donate. To ensure the safety of blood, donor testing was performed again after donation. After the implementation of the Blood Donation Law in 1998, to promote voluntary and unpaid donation, predonation donor testing was eliminated to reduce the amount of waiting time and to provide a more convenient donation experience for blood donors. However, it is the national requirement that donated blood should undergo 2 rounds of testing using different equipment or reagents, conducted by different personnel. Donor selection has transitioned from paid donation and obligatory donation to voluntary donation with fixed volunteer groups, as the latter mode of donation provides the lowest risks. Donations are currently screened for syphilis, hepatitis C virus, HIV, and hepatitis B virus (HBV). Units, previously typed only for ABO, are now routinely tested for both ABO and Rh(D). Innovations in testing technologies and methods have also brought changes to screening parameters. For instance, screening for HBV pathogens evolved from the early use of hemagglutination method to the later use of radioimmunoassay, independent enzyme-linked immunosorbent assay, and now the widespread application of nucleic acid test (NAT). Since 2010, the Chinese government has established NAT capacity in several blood centers; and in 2015, the government invested 900 million RMB on the nationwide expansion of NAT. Although the Chinese government has worked to enhance blood safety, many challenges remain. Concern exists for rising rates of HIV infection. The existence of occult HBV infection and the transmission of emerging blood-borne diseases continue to challenge the safety of the blood supply. Copyright © 2017 Elsevier Inc. All rights reserved.
Wang, Jingxing; Liu, Jing; Huang, Yi; Wright, David J; Li, Julin; Zhou, Zhongmin; He, Weilan; Yang, Tonghan; Yao, Fuzhu; Zhu, Xiangming; Wen, Guoxin; Bi, Xinhong; Tiemuer, Mei-hei-li; Wen, Xiuqiong; Huang, Mei; Cao, Ru'an; Yun, Zhongqiao; Lü, Yunlai; Ma, Hongli; Guo, Nan; Yu, Qilu; Ness, Paul; Shan, Hua
2013-10-01
A total of 2%-2.9% of the population in China is infected with hepatitis C virus (HCV). This study estimated the prevalence and incidence of HCV among Chinese blood donors. We examined whole blood and apheresis platelet donations at five Chinese blood centers in 2008 to 2010. All donations were screened using two rounds of testing for alanine aminotransferase, antibody to human immunodeficiency virus Types 1 and 2, hepatitis B surface antigen, anti-HCV, and syphilis. Screening reactivity is defined by a reactive result in one or both rounds of screening tests. Confirmatory tests (Ortho third-generation HCV enzyme immunoassay, Johnson & Johnson) were performed on anti-HCV screening-reactive samples. Confirmatory positive rates among first-time donors (prevalence) and repeat donors (incidence) were calculated by blood center and demographic categories. Donor characteristics associated with HCV confirmatory status among first-time donors were examined using trend test and multivariable logistic regression analysis. Among 821,314 donations, 40% came from repeat donors. The overall anti-HCV screening-reactive rate was 0.48%. Estimated HCV prevalence was 235 per 100,000 first-time donors; incidence was 10 per 100,000 person-years in repeat donors. In multivariable logistic regression analysis, first-time donors older than 25 years displayed higher HCV prevalence than the younger donors. Less education is associated with higher HCV prevalence. Donors 26 to 35 years old and those above 45 years displayed the highest incidence rate. High prevalence and incidence in donors indicate high residual risks for transfusion-transmitted HCV in Chinese patients. Implementation of minipool nucleic acid testing in routine donation screening may prevent a substantial number of transfusion-transmitted HCV infections. © 2013 American Association of Blood Banks.
Lin, K T; Chang, C L; Tsai, M H; Lin, K S; Saldanha, J; Hung, C M
2014-02-01
The ability of a new generation commercial, multiplex, multi-dye test from Roche, the cobas TaqScreen MPX test, version 2.0, to detect and identify occult HBV infections was evaluated using routine donor samples from Kaohsiung Blood Bank, Taiwan. A total of 5973 samples were tested by nucleic acid amplification technology (NAT); 5898 in pools of six, 66 in pools of less than six and nine samples individually. NAT-reactive samples were retested with alternative NAT tests, and follow-up samples from the donors were tested individually by NAT and for all the HBV serological markers. Eight NAT-only-reactive donors were identified, and follow-up samples were obtained from six of the donors. The results indicated that all eight donors had an occult HBV infection with viral loads <12 IU/ml. The cobas(®) TaqScreen MPX test, version 2.0, has an advantage over the current Roche blood screening test, the cobas TaqScreen MPX test, for screening donations in countries with a high prevalence of occult HBV infections since the uncertainty associated with identifying samples with very low viremia is removed by the ability of the test to identify the viral target in samples that are reactive with the cobas TaqScreen MPX test, version 2.0. © 2013 International Society of Blood Transfusion.
ESHRE Task Force on Ethics and Law 21: genetic screening of gamete donors: ethical issues.
Dondorp, W; De Wert, G; Pennings, G; Shenfield, F; Devroey, P; Tarlatzis, B; Barri, P; Diedrich, K; Eichenlaub-Ritter, U; Tüttelmann, F; Provoost, V
2014-07-01
This Task Force document explores the ethical issues involved in the debate about the scope of genetic screening of gamete donors. Calls for expanded donor screening arise against the background of both occasional findings of serious but rare genetic conditions in donors or donor offspring that were not detected through present screening procedures and the advent of new genomic technologies promising affordable testing of donors for a wide range of conditions. Ethical principles require that all stakeholders' interests are taken into account, including those of candidate donors. The message of the profession should be that avoiding all risks is impossible and that testing should remain proportional.
Optimal screening and donor management in a public stool bank.
Kazerouni, Abbas; Burgess, James; Burns, Laura J; Wein, Lawrence M
2015-12-17
Fecal microbiota transplantation is an effective treatment for recurrent Clostridium difficile infection and is being investigated as a treatment for other microbiota-associated diseases. To facilitate these activities, an international public stool bank has been created, which screens donors and processes stools in a standardized manner. The goal of this research is to use mathematical modeling and analysis to optimize screening and donor management at the stool bank. Compared to the current policy of screening active donors every 60 days before releasing their quarantined stools for sale, costs can be reduced by 10.3 % by increasing the screening frequency to every 36 days. In addition, the stool production rate varies widely across donors, and using donor-specific screening, where higher producers are screened more frequently, also reduces costs, as does introducing an interim (i.e., between consecutive regular tests) stool test for just rotavirus and C. difficile. We also derive a donor release (i.e., into the system) policy that allows the supply to approximately match an exponentially increasing deterministic demand. More frequent screening, interim screening for rotavirus and C. difficile, and donor-specific screening, where higher stool producers are screened more frequently, are all cost-reducing measures. If screening costs decrease in the future (e.g., as a result of bringing screening in house), a bottleneck for implementing some of these recommendations may be the reluctance of donors to undergo serum screening more frequently than monthly.
Niazi, Saifullah Khan; Alam, Maqbool; Yazdani, Muhammad Sajid; Ghani, Eijaz; Rathore, Muhammad Ali
2017-01-01
The study was planned to determine the presence of West Nile Virus (WNV) infection in Pakistani blood donors, using Nucleic Acid Amplification Test (NAT). The blood donors for study were selected on the basis of the standard questionnaire and routine screening results. Six donors were pooled using an automated pipettor and NAT for WNV was performed on Roche Cobas s 201 NAT system. The reactive pools were resolved in Individual Donation-NAT (ID-NAT) format and a sample from FFP bags of reactive donations was retrieved. NAT was again performed on retrieved plasma bag (RPB) sample to confirm the reactive donations. The donors were also recalled and interviewed about history of illness related to recent WNV infection. After serological screening of 1929 donors during the study period, 1860 donors were selected for NAT test for WNV detection. The mean age of the donors was 28±8.77 (range: 18-57 years). 1847 (99.3%) donors were male and 13 (0.7%) were female. NAT for WNV identified six initially reactive pools (0.32%). On follow-up testing with RPB samples, 4 donors (0.21%) were found confirmed reactive for WNV RNA (NAT yield of 1 in 465 blood donors). WNV is a threat to safety of blood products in Pakistan. A screening strategy can be implemented after a large-scale study and financial considerations. One of the reduced cost screening strategies is seasonal screening of blood donors for WNV, with pooling of samples.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-05
...The Food and Drug Administration (FDA) is announcing the availability of a draft document entitled ``Guidance for Industry: Use of Donor Screening Tests to Test Donors of Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) for Infection with Treponema pallidum (Syphilis),'' dated October 2013. The draft guidance document provides establishments that make donor eligibility determinations for donors of HCT/Ps (HCT/P Establishments), with updated recommendations concerning donor testing for evidence of Treponema pallidum (T. pallidum) infection, the etiologic agent of syphilis. HCT/P Establishments must, as required under Federal regulations, test a donor specimen for evidence of T. pallidum infection using appropriate FDA-licensed, approved, or cleared donor screening tests, in accordance with the manufacturer's instructions, unless an exception to this requirement applies. The draft guidance clarifies that FDA does not consider diagnostic tests or pre-amendment devices (which have not been licensed, approved, or cleared) to be adequate for use in donor testing for T. pallidum infection under the criteria specified in Federal regulations. The recommendations in this guidance, when finalized, will supersede those recommendations for testing HCT/P donors for evidence of T. pallidum infection contained in the document entitled ``Guidance for Industry: Eligibility Determination for Donors of Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps),'' dated August 2007.
Predonation screening of candidate donors and prevention of window period donations.
Lieshout-Krikke, Ryanne W; Zaaijer, Hans L; van de Laar, Thijs J W
2015-02-01
Infectious window period donations slip through routine donor screening procedures. To explore the potential value of predonation screening of candidate donors, we compared the proportion of incident transfusion-transmissible infections in candidate donors, in first-time donors, and in repeat donors. A retrospective analysis was performed of all incident hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) infections in candidate, first-time, and repeat donors in the Netherlands during the period 2009 to 2013. In total, 176,716 candidate donors, 144,226 first-time donations, and 4,143,455 repeat donations were screened for HBV, HCV, and HIV infection. Acute HBV infection was identified in the predonation sample of six candidate donors. One first-time donor, testing HIV-negative at predonation screening, tested positive for anti-HIV and HIV RNA in the first donation 29 days later. Among repeat donations we identified 15, one, and six incident HBV, HCV and HIV infections, respectively. The proportion of incident infections among candidate donors/first-time donations/repeat donations was for HBV, 3.40/0/0.36; for HCV, 0/0/0.02; and for HIV 0/0.69/0.14 per 100,000, respectively. Predonation screening of candidate donors very likely causes a loss of donations, but it might prevent undetected window period donations. Further studies are necessary to determine the value of predonation screening as an additional safety measure. © 2014 AABB.
Transmission of Hepatitis C Virus From Organ Donors Despite Nucleic Acid Test Screening.
Suryaprasad, A; Basavaraju, S V; Hocevar, S N; Theodoropoulos, N; Zuckerman, R A; Hayden, T; Forbi, J C; Pegues, D; Levine, M; Martin, S I; Kuehnert, M J; Blumberg, E A
2015-07-01
Nucleic acid testing (NAT) for hepatitis C virus (HCV) is recommended for screening of organ donors, yet not all donor infections may be detected. We describe three US clusters of HCV transmission from donors at increased risk for HCV infection. Donor's and recipients' medical records were reviewed. Newly infected recipients were interviewed. Donor-derived HCV infection was considered when infection was newly detected after transplantation in recipients of organs from increased risk donors. Stored donor sera and tissue samples were tested for HCV RNA with high-sensitivity quantitative PCR. Posttransplant and pretransplant recipient sera were tested for HCV RNA. Quasispecies analysis of hypervariable region-1 was used to establish genetic relatedness of recipient HCV variants. Each donor had evidence of injection drug use preceding death. Of 12 recipients, 8 were HCV-infected-6 were newly diagnosed posttransplant. HCV RNA was retrospectively detected in stored samples from donor immunologic tissue collected at organ procurement. Phylogenetic analysis showed two clusters of closely related HCV variants from recipients. These investigations identified the first known HCV transmissions from increased risk organ donors with negative NAT screening, indicating very recent donor infection. Recipient informed consent and posttransplant screening for blood-borne pathogens are essential when considering increased risk donors. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.
Walsh, A P H; Omar, A B; Collins, G S; Murray, G U; Walsh, D J; Salma, U; Sills, E Scott
2010-01-01
Anonymous oocyte donation in the EU proceeds only after rigorous screening designed to ensure gamete safety. If anonymous donor gametes originating from outside EU territory are used by EU patients, donor testing must conform to the same standards as if gamete procurement had occurred in the EU. In Ireland, IVF recipients can be matched to anonymous donors in the Ukraine (a non-EU country). This investigation describes the evolution of anonymous oocyte donor screening methods during this period and associated results. Data were reviewed for all participants in an anonymous donor oocyte IVF programme from 2006 to 2009, when testing consistent with contemporary EU screening requirements was performed on all Ukrainian oocyte donors. HIV and hepatitis tests were aggregated from 314 anonymous oocyte donors and 265 recipients. The results included 5,524 Ukrainian women who were interviewed and 314 of these entered the programme (5.7% accession rate). Mean age of anonymous oocyte donors was 27.9 years; all had achieved at least one delivery. No case of hepatitis or HIV was detected at initial screening or at oocyte procurement. This is the first study of HIV and hepatitis incidence specifically among Ukrainian oocyte donors. We find anonymous oocyte donors to be a low-risk group, despite a high background HIV rate. Following full disclosure of the donation process, most Ukrainian women wishing to volunteer as anonymous oocyte donors do not participate. Current EU screening requirements appear adequate to maintain patient safety in the context of anonymous donor oocyte IVF.
Screening blood donors for human immunodeficiency virus antibody: cost-benefit analysis.
Eisenstaedt, R S; Getzen, T E
1988-01-01
The costs and benefits of screening blood donors for antibody to human immunodeficiency virus (HIV) are assessed. Total costs, including testing, discarding processed blood, marginal donor recruiting, notifying and evaluating positive donors, are $36,234,000 annually for 10 million donors in 1986. Screening these donors will prevent 292 cases of transfusion-transmitted acquired immune deficiency syndrome (TT-AIDS), saving the costs of therapy and loss of earnings for total benefits of $43,490,480, a benefit:cost ratio of 1.2:1. Net economic benefits of $0.73 per donor will arise from the program. Calculated benefits will rise as increased numbers of infected recipients are diagnosed with longer follow-up or as partially effective therapy increases the cost of caring for patients with AIDS. Changes in test sensitivity, follow-up procedures, estimated value of life, and testing costs will also alter these projections, but none as dramatically as a change in the overall specificity of the screening process. The cost per case of TT-AIDS prevented, $124,089, and cost per year of life extended, $10,885, are comparable to costs of other screening programs. PMID:3126676
Abanyie, Francisca A; Valice, Emily; Delli Carpini, Kristin W; Gray, Elizabeth B; McAuliffe, Isabel; Chin-Hong, Peter V; Handali, Sukwan; Montgomery, Susan P; Huprikar, Shirish
2018-03-07
Targeted donor screening for strongyloidiasis performed at the time of organ procurement can prevent this life-threatening donor-derived infection. The Association of Organ Procurement Organizations surveyed members to determine the number of US organ procurement organizations (OPOs) performing donor screening for Strongyloides infection and their screening practices. All 58 OPOs responded to the survey. Only 6 (10%) currently screen donors for strongyloidiasis; most OPOs started 6-36 months before the survey and one started 6 years prior. All used risk-based criteria to determine which donors to screen, though the criteria varied among OPOs. A median of 56 donors have been screened at each OPO since initiating their screening programs, with a median of 2 infected donors (range 0-13) identified. Overall, 53 organs have been transplanted from 22 infected donors, including hearts, lungs, kidneys, and livers. Of 52 OPOs not currently screening, 20 had considered screening and one plans to start screening in the near future. Of those considering risk-based screening, most had not decided on the criteria. Uncertainty about the benefits of and guidelines for screening and misconceptions about the interpretation of test results were concerns shared by non-screening OPOs. Continued education and advocacy on the importance of targeted donor screening are needed. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Olotu, Amadin A; Oyelese, Adesola O; Salawu, Lateef; Audu, Rosemary A; Okwuraiwe, Azuka P; Aboderin, Aaron O
2016-05-05
Hepatitis B virus (HBV) transmission through blood transfusion is reduced by screening for hepatitis B surface antigen (HBsAg). However this method cannot detect the presence of occult hepatitis B virus infection. This study sought to determine the prevalence of occult hepatitis B virus infection among blood donors in Ile-Ife, Nigeria. For the first time in Nigeria we employed an automated real-time PCR- method to investigate the prevalence of occult HBV in blood donors. Blood donors screened with HBsAg immunochromatographic rapid test kits at the blood transfusion units of two hospitals and found to be negative were recruited into the study. Questionnaires to elicit risk factors for HBV infection were administered and then 10 ml of blood was collected from each donor. Plasma samples obtained from these HBsAg negative blood donors were screened again for HBsAg using an enzyme-linked immunosorbent assay (ELISA) method, and those found negative were screened for the presence of total antibody to the HBV core antigen (anti-HBc) using ELISA method. Those positive to anti-HBc were then tested for HBV DNA, using an automated real-time PCR method. Five hundred and seven blood donors found HBsAg negative by immunochromatographic rapid test kits at both blood transfusion units, were tested for HBsAg using ELISA and 5 (1 %) were HBsAg positive. The 502 found negative were tested for anti-HBc and 354 (70.5 %) were found positive implying previous exposure to HBV and 19 (5.4 %) of the 354 anti-HBc positive had HBV DNA signifying occult HBV infection. No risk factors were found to be associated with the presence of HBV DNA among those who tested positive. Occult HBV infection exists in blood donors in Ile-Ife, Nigeria and the use of HBsAg alone for screening prospective donors will not eliminate the risk of HBV transmission in blood transfusion or stem cell transplantation.
Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R
2017-06-01
We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.
Furuta, Rika A; Ma, Guangyong; Matsuoka, Masao; Otani, Satoshi; Matsukura, Harumichi; Hirayama, Fumiya
2015-04-01
Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies. © 2014 AABB.
El Ghouzzi, Marie-Hélène; Boiret, Elisabeth; Wind, Françoise; Brochard, Claudine; Fittere, Sébastien; Paris, Luc; Mazier, Dominique; Sansonetti, Nicole; Bierling, Philippe
2010-03-01
Chagas disease is endemic in Latin America (LA). Currently 10 million people are infected despite World Health Organization efforts aimed at preventing domestic transmission. However, with the migration of infected asymptomatic individuals to nonendemic countries, transmission of Chagas disease by transfusion may become a worldwide problem. The observation that the number of cases of Chagas disease has increased over the past 10 years in French Guiana, together with the results of a previous hospital-based study in the Paris area, confirms the transmission of Chagas disease from patients coming from LA. For these reasons, the French authorities stopped the collection of blood in French Guiana in 2005 and began screening blood donors in the French Caribbean islands and, in 2007, in continental France. Data on birth place, mother's birth place, and travel in LA were recorded for at-risk donors. These subjects were tested using two enzyme-linked immunosorbent assays (ELISAs). Of the 312,458 individuals who gave blood in the Paris area during an 18-month period, 30,837 were tested. Of these, 972 were born in LA, three of whom were positive for the two ELISAs and immunofluorescence tests. The prevalence of Trypanosoma cruzi-positive donors was 9.7 in 100,000 tested donors, but 0.31% among donors born in LA. Serology tests gave discrepant results in 1.02% of the samples. The efficiency of blood donor screening programs could be improved by screening only blood donors who were born in LA or who have traveled in LA for extended periods, using a single enzyme immunoassay.
Moritz, Erin D; Tonnetti, Laura; Hewins, Mary Ellen; Berardi, Victor P; Dodd, Roger Y; Stramer, Susan L
2017-07-01
Blood donation screening detecting only antibodies fails to identify donors in the earliest stage of infection, before a detectable immunologic response, that is, the "window period" (WP). We present data on WP donations identified during prospective screening for Babesia microti, a transfusion-transmissible parasite of increasing concern in the United States. Blood donations collected in Connecticut, Massachusetts, Minnesota, and Wisconsin were screened using polymerase chain reaction (PCR) and arrayed fluorescence immunoassay (AFIA) to detect B. microti DNA and antibodies, respectively. Parasite loads were estimated using quantitative PCR. Red blood cell (RBC) samples were inoculated into hamsters to assess infectivity. Donors screening reactive were indefinitely deferred, tested by supplemental methods, and followed to assess DNA and antibody clearance. Demographic data from WP donors (i.e., those screening PCR positive and AFIA negative) were compared to data from other positive donors. Of 220,479 donations screened from June 2012 to August 2016, a total of 700 were positive, of which 15 (2% of positive donations or 1 per 14,699 screened donations) were confirmed WP donations. The median estimated parasite load in WP donations was 350 parasites/mL, no different than AFIA-positive and PCR-positive donors. Parasite loads in RBC samples from WP units ranged from 14 to 11,022 parasites/mL; RBC samples from three of 10 (30%) WP donations infected hamsters. The mean age of WP donors was 48 years (range, 17-75 years); three (20%) were female. WP donor demographics did not differ significantly from demographics of other donors. We report one per 15,000 B. microti WP infections in blood donors in endemic areas, demonstrating the importance of nucleic acid testing to mitigate the risk of transfusion-transmitted babesiosis. © 2017 AABB.
Neish, Emma M.; Miller, Nancy S.; Dhere, Tanvi; Burd, Eileen M.; Carpentieri, Cynthia; Sitchenko, Kaitlin L.
2017-01-01
ABSTRACT Fecal microbiota transplantation is an efficacious and inexpensive therapy for recurrent Clostridium difficile infection, yet its safety is thought to depend on appropriate fecal donor screening. FDA guidance for regulation of this procedure is in flux, but screening and manufacture of fecal material from asymptomatic donors present many challenges to clinical laboratories. This minireview summarizes FDA regulatory changes, principles of donor selection, and recommended laboratory screening practices for fecal microbiota transplantation. PMID:28077694
Conrad, E A; Fine, B; Hecht, B R; Pergament, E
1996-01-01
To determine how the screening practices of commercial semen banks vary from published guidelines, which factors influence cryobanks to exclude prospective semen donors for genetic reasons, and the current role of clinical geneticists/genetic counselors in evaluating prospective semen donors. The genetic screening of prospective donors by commercial semen banks was evaluated using written questionnaires completed by bank directors. Responses were analyzed to determine exclusion criteria, adherence to published guidelines, and contribution of genetic professionals. Semen banks were selected on the basis of membership in the American Association of Tissue Banks and commercial use of semen for artificial insemination by donor. Semen bank practices as reported by commercial semen bank directors. Of 37 eligible banks, 16 responded. All screen prospective donors by medical/family history and physical examination, 94% have upper age limits; 63% examine for minor physical defects; 56% routinely karyotype; 81% screen men of ethnic groups at risk for Tay Sachs disease, sickle cell disease and thalassemia; 19% screen all donors; 25% screen all donors for cystic fibrosis and 50% only screen if family history positive. Donor rejection was based on three criteria: mode of inheritance of familial disorder, severity of disease, and availability of carrier/confirmatory testing of donor genotype. Ten of 16 banks have no genetic professional on staff. Commercial semen banks primarily rely on family history as the major exclusion criterion in genetic screening of donors. Considerable differences exist among semen bank practices in accordance with guidelines published by national agencies. Genetic professionals have a minimal effect overall on evaluation of semen donors.
First Zika-positive donations in the continental United States.
Galel, Susan A; Williamson, Phillip C; Busch, Michael P; Stanek, Danielle; Bakkour, Sonia; Stone, Mars; Lu, Kai; Jones, Scott; Rossmann, Susan N; Pate, Lisa Lee
2017-03-01
Zika virus (ZIKV) has spread in the Americas, including parts of the southern United States, and infection can be associated with serious complications, including congenital brain abnormalities. Probable transfusion transmission of ZIKV has been documented in Brazil. Preemptive testing of blood donations for ZIKV RNA was implemented in southern US states at risk of local transmission using a test approved under a Food and Drug Administration (FDA) investigational new drug application, cobas Zika. Screening was expanded after issuance of an updated FDA guidance. Donations reactive on initial screening were further tested by nucleic acid and antibody tests to determine the donor status. Of 358,786 donations from US states screened by individual donation testing, 23 were initially reactive on cobas Zika. Fourteen of these represented probable ZIKV infection based on reactivity on additional nucleic acid testing or anti-Zika immunoglobulin M. Ten of the 14 donors reported travel to an identified ZIKV-active area within 90 days before donation (median time from end of travel to donation, 25 days; range, 6-71 days). Three donors with travel history also had a potential sexual exposure. Only seven of the 14 donations with probable ZIKV infection were detectable upon 1:6 dilution to simulate minipool testing. The estimated specificity of the cobas Zika test was 99.997%. Screening of donations for ZIKV RNA can interdict ZIKV-infected donors. Donor risk factors include travel more than 4 weeks before donation and sexual exposure. Minipool screening would have detected only 50% of the RNA-positive donations. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
Hepatitis B transmission by cell and tissue allografts: How safe is safe enough?
Solves, Pilar; Mirabet, Vicente; Alvarez, Manuel
2014-01-01
More than 2 million human tissue transplants (bone, tendon, cartilage, skin, cornea, amniotic membrane, stem cells, heart valve, blood vessel, etc.), are performed worldwide every year. Cells and tissues are shared between countries which have different regulations and laboratory equipment and represent a risk of hepatitis B virus (HBV) transmission that has become a global safety concern. While the risk of transfusion-transmitted HBV infection from blood donations has been estimated, the rate of HBV transmission from donors to recipients of allografts is unknown and varies between different tissues. There are various important ways of reducing the transmission risk, but donor screening and donor testing are still the main factors for preventing HBV transmission. HBV detection is included in the routine screening tests for cell and tissue donors. The standard test for preventing transplant-transmitted hepatitis B is the hepatitis B surface antigen. The implementation of methods involving nucleic acid amplification and the new generation of reactives to detect viral antibodies or antigens with an immunoassay, has increased the sensitivity and the specificity of the screening tests. The objective of our research was to review the literature and critically analyse the different steps for avoiding HBV transmission in cell and tissue donors, focusing on the screening tests performed. PMID:24966613
Tyrrell, A; Worrall, E; Que, T N; Bates, I
2011-06-01
To compare the cost and effectiveness of Copper Sulphate (CS) and HemoCue (HC) methods for screening blood donors for anaemia. Robust information from developing countries about cost and effectiveness of anaemia screening methods for blood donors is scarce. In such countries there are widespread shortages of blood, so the most cost-effective method should maximise blood supply without compromising donor safety. Economic data (e.g. staff time, equipment and buildings) were collected from direct observation of procedures and purchase data from Hanoi's Central Blood Bank administrative department. A framework for comparing the cost and effectiveness of anaemia screening methods was developed and a cost per effective (i.e. usable and accurate) test was generated for each method. Samples from 100 potential donors from the Hanoi Central Blood Bank (static) and 198 from two mobile units were tested. The mean probability of an ineffective anaemia test was 0·1 (0·05-0·2). The average cost of an HC test was $0·75 (static $0·61 and mobile $0·89) and a CS test was $0·31 (static $0·17 and mobile $0·45). The difference between static and mobile units was predominantly due to transport costs; the difference between the two methods was predominantly due to the HC microcuvettes. In this setting the CS yields greater value for money than the HC method for screening blood donors. The relative cost and effectiveness of CS and HC may be different in places with higher staff turnover, lower test accuracy, higher anaemia prevalence or lower workload than in Vietnam. © 2010 Liverpool School of Tropical Medicine. Transfusion Medicine © 2010 British Blood Transfusion Society.
Pereira, Gilberto de Araujo; Louzada-Neto, Francisco; Barbosa, Valdirene de Fátima; Ferreira-Silva, Márcia Maria; de Moraes-Souza, Helio
2012-01-01
The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.
2014-01-01
Background After the largest outbreaks of Q fever ever recorded in history occurred in the Netherlands, concern arose that Coxiella may be transmitted via donated tissues of latent or chronically infected donors. The Dutch Health Council recently advised to screen tissue donors, donating high risk tissues, for Coxiella infection. Methods After validation of an enzyme immunoassay (EIA) test for IgG antibodies against phase 2 of C. burnetii for use on post-mortem samples, serum samples of 1033 consecutive Dutch post-mortem tissue donors were tested for IgG antibodies against phase 2 of C. burnetii. Confirmation of reactive results was done by immunofluorescence assay (IFA). All available tissues (corneas, heart valves, skin and bone marrow) from donors with IgG reactivity were tested for presence of Coxiella DNA by PCR. Risk factors for IgG reactivity were investigated. Results After validation of the tests for use on post-mortem samples, 50/1033 donors (4.8%) screened positive for phase 2 anti-Coxiella IgG by EIA, and 31 were confirmed by IFA (3.0%). One donor showed a serological profile compatible with chronic infection. All tested tissues (25 corneas, 6 heart valves, 4 skin and 3 bone marrow) from donors with IgG reactivity tested negative for the presence of Coxiella DNA. Except for living in a postal code area with a high number of Q fever notifications, no risk factors for IgG reactivity were found. Conclusions The strong correlation between notifications and seroprevalence confirms that the used assays are sufficiently specific for use on post-mortem samples, although one has to be aware of differences between batches. Thus, this study provides a validated method for screening tissue donors for infection with Coxiella burnetii that can be used in future outbreaks. PMID:24393298
Zuck, T F; Cumming, P D; Wallace, E L
2001-12-01
The safety of blood for transfusion depends, in part, on the reliability of the health history given by volunteer blood donors. To improve reliability, a pilot study evaluated the use of an interactive computer-based audiovisual donor interviewing system at a typical midwestern blood center in the United States. An interactive video screening system was tested in a community donor center environment on 395 volunteer blood donors. Of the donors using the system, 277 completed surveys regarding their acceptance of and opinions about the system. The study showed that an interactive computer-based audiovisual donor screening system was an effective means of conducting the donor health history. The majority of donors found the system understandable and favored the system over a face-to-face interview. Further, most donors indicated that they would be more likely to return if they were to be screened by such a system. Interactive computer-based audiovisual blood donor screening is useful and well accepted by donors; it may prevent a majority of errors and accidents that are reportable to the FDA; and it may contribute to increased safety and availability of the blood supply.
Dosunmu, Adedoyin Owolabi; Akinbami, Akinsegun Abduljaleel; Ismail, Ayobami Kamal; Olaiya, Modupe Adebimpe; Uche, Ebele Ifeyinwa; Aile, Igbinoba Kingsley
2017-01-01
Blood transfusion practice emphasises safety, efficacy and appropriate use. These require cost-effective programme management. This study focused on the cost of screening for transfusion transmissible infections (TTI). This was a 1 year (2016) analysis of screening in a hospital-based transfusion centre. The cost of screening all blood donors by ELISA was compared to the cost of serial screening starting from rapid kit, taking into account, the estimated cost of blood bags prevented from discard after ELISA screening (attributable cost). The cost of voluntary donor drive plus cost of ELISA screening was compared with the present cost of screening. A total of 5591 donors were screened for HIV, hepatitis B and C using the rapid kit, 291 donors were deferred (5.2%). A total of 5300 units were further screened by ELISA. A total of 435 blood units (8.2%) were discarded due to TTI positivity. TTI positivity rate was 12.98%. Only 2.36% were voluntary donors and among these 9.1% were TTI positive. The attributable cost of serial screening was 55,653.5 USD while that of screening by ELISA only was 55,910 USD. The attributable cost of rapid screening for only hepatitis B and then ELISA was 53,313.9 USD taking into consideration that 187 blood units would be prevented from undue discard. This analysis demonstrated that with proper donor selection, rapid screening for hepatitis B virus only before ELISA screening is more cost-effective. This will also reduce the waiting time for donors and counselling if HIV positive.
Heim, Albert
2016-05-01
The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p < 0.001) which included non-heart-beating ('cadaveric') donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors.
Victer, Thayssa Neiva da Fonseca; Dos Santos, Cris Stéphany Rodrigues; Báo, Sônia Nair; Sampaio, Thatiane Lima
2016-12-01
Vital to patient safety is the accurate assessment and minimization of risk for human immunodeficiency virus (HIV), Hepatitis C (HCV), and Hepatitis B (HBV) virus transmission by deceased donor organ and tissue transplantation. The pathogens are tested by serological kits based on enzyme-linked immunosorbent assay (ELISA), chemiluminescence (CLIA) and eletrochemiluminescence (ECLIA) immunoassays. Organ transplantation is a highly successful life-saving treatment in Brazil, but the Brazilian Health Surveillance Agency currently mandates that all deceased organ donors are screened for HIV, HCV and HBV following living donor policies. In this review, six ELISA (Wama ® , Bio-Rad ® , Biomerieux ® , DiaSorin ® , Acon Biotech ® and Biokit ® ), three CLIA (Abbott ® , Siemens ® , Diasorin ® ) and one ECLIA (Roche ® ) were utilized for evaluating the effectiveness of those serological tests for deceased donors in Brazil according to manufacturer's guidelines. NAT for HIV, HCV and HBV can assist with detection of pre-seroconversion for those infections, and only Cobas ® TaqScreen MPX ® test, the Tigris System ® Procleix Ultrio Assay ® and the Bio-Manguinhos ® HIV/HCV/HBV NAT are commercially available. Between all the tests, only the manufacturer Abbott ® and Cobas ® TaqScreen MPX ® test are currently validated for cadaver samples.
Donor screening for hepatitis B virus infection in a cell and tissue bank.
Solves, P; Mirabet, V; Alvarez, M; Vila, E; Quiles, F; Villalba, J V; Montoro, J A; Soler, M A; Roig, R J
2008-12-01
Hepatitis B virus (HBV) has been transmitted by tissue transplantation. In order to reduce the risk of HBV transmission, testing for antibody to HBV core antigen (anti-HBc) is used in addition to testing for hepatitis B surface antigen (HBsAg) in many blood centers and tissue banks. We retrospectively analyzed the results of HBV assays in tissue donors. All tissue donors were tested for HBsAg and anti-HBc. All anti-HBc positive sera were tested for the antibody to HBsAg (anti-HBs). From July 2006, an HBV nucleic acid testing (NAT) assay was also performed. A total of 6855 tissue donors from January 1999 till July 2007 were tested for HBV assays: 4756 women and 2099 men. Positive HBsAg was found in 23 (0.36%) living donors, while no multiorgan or cord blood (CB) donor was found to be positive for HBsAg. Positive anti-HBc was found in 80 multiorgan donors (12.94%), 599 living donors (17.84%), and 103 CB donors (3.57%) (P<0.005), while isolated anti-HBc was found in 12 multiorgan (1.94%), in 126 living tissue donors (3.75%), and in 8 CB donors (0.28%). A total of 1310 donors were analyzed for single-sample DNA HBV NAT assay. We consider that anti-HBc and NAT assays must both still be performed in addition to HBsAg assay for HBV screening in tissue donors. All these tests will be useful in order to define an algorithm for safe and efficient management of the tissue bank.
Gómez-Simón, Antonia; Navarro-Núñez, Leyre; Pérez-Ceballos, Elena; Lozano, María L; Candela, María J; Cascales, Almudena; Martínez, Constantino; Corral, Javier; Vicente, Vicente; Rivera, José
2007-06-01
Predonation hemoglobin measurement is a problematic requirement in mobile donation settings, where accurate determination of venous hemoglobin by hematology analyzers is not available. We have evaluated hemoglobin screening in prospective donors by the semiquantitative copper sulphate test and by capillary blood samples analyzed by three portable photometers, HemoCue, STAT-Site MHgb, and the CompoLab HB system. Capillary blood samples were obtained from 380 donors and tested by the copper sulphate test and by at least one of the named portable photometers. Predonation venous hemoglobin was also determined in all donors using a Coulter Max-M analyzer. The three photometers provided acceptable reproducibility (CV below 5%), and displayed a significant correlation between the capillary blood samples and the venous hemoglobin (R2 0.5-0.8). HemoCue showed the best agreement with venous hemoglobin determination, followed by STAT-Site MHgb, and the CompoLab HB system. The copper sulphate test provided the highest rate of donors acceptance (83%) despite unacceptable hemoglobin levels, and the lowest rate for donor deferral (1%) despite acceptable hemoglobin levels. The percentage of donors correctly categorized for blood donation by the portable hemoglobinometers was 85%, 82%, and 76% for CompoLab HB system, HemoCue and STAT-Site, respectively. Our data suggest that hemoglobin determination remains a conflictive issue in donor selection in the mobile setting. Without appropriate performance control, capillary hemoglobin screening by either the copper sulphate method or by the novel portable hemoglobinometers could be inaccurate, thus potentially affecting both donor safety and the blood supply.
Recipient screening in IVF: first data from women undergoing anonymous oocyte donation in Dublin.
Walsh, Anthony P H; Omar, Ahmed B; Marron, Kevin D; Walsh, David J; Salma, Umme; Sills, E Scott
2011-04-20
Guidelines for safe gamete donation have emphasised donor screening, although none exist specifically for testing oocyte recipients. Pre-treatment assessment of anonymous donor oocyte IVF treatment in Ireland must comply with the European Union Tissues and Cells Directive (Directive 2004/23/EC). To determine the effectiveness of this Directive when applied to anonymous oocyte recipients in IVF, we reviewed data derived from selected screening tests performed in this clinical setting. Data from tests conducted at baseline for all women enrolling as recipients (n = 225) in the anonymous oocyte donor IVF programme at an urban IVF referral centre during a 24-month period were analysed. Patient age at programme entry and clinical pregnancy rate were also tabulated. All recipients had at least one prior negative test for HIV, Hepatitis B/C, chlamydia, gonorrhoea and syphilis performed by her GP or other primary care provider before reproductive endocrinology consultation. Mean (±SD) age for donor egg IVF recipients was 40.7 ± 4.2 yrs. No baseline positive chlamydia, gonorrhoea or syphilis screening results were identified among recipients for anonymous oocyte donation IVF during the assessment interval. Mean pregnancy rate (per embryo transfer) in this group was 50.5%. When tests for HIV, Hepatitis B/C, chlamydia, gonorrhoea and syphilis already have been confirmed to be negative before starting the anonymous donor oocyte IVF sequence, additional (repeat) testing on the recipient contributes no new clinical information that would influence treatment in this setting. Patient safety does not appear to be enhanced by application of Directive 2004/23/EC to recipients of anonymous donor oocyte IVF treatment. Given the absence of evidence to quantify risk, this practice is difficult to justify when applied to this low-risk population.
Inojosa, W O; Scotton, P G; Fuser, R; Giobbia, M; Paolin, A; Maresca, M C; Brunello, A; Nascimben, E; Sorbara, C; Rigoli, R; Berti, R; Gajo, G B; Giometto, B
2012-10-01
West Nile virus (WNV) transmission through organ transplantation occurs rarely and screening of organ donors for WNV infection remains controversial. This report describes the case of WNV encephalitis in a kidney recipient and the case of asymptomatic WNV infection in the organ donor, both observed at Treviso Hospital, northeastern Italy. After briefly reviewing the literature, we discuss the implications for WNV screening. We reviewed medical, laboratory and epidemiological records at our hospital, and the literature concerning cases of organ-transmitted WNV infections and WNV screening of organ donors in Italy and worldwide. The kidney recipient was the first confirmed case of WNV infection notified in northeastern Italy in 2011, and the first case of WNV infection in a cluster of four transplant recipients who acquired the infection from a common organ donor. The organ donor, whose WNV infection was only retrospectively diagnosed by IgM detection, represents the index case of a WNV outbreak in the Treviso Province. Screening of her blood prior to organ recovery did not show detectable levels of WNV nucleic acid with the use of quantitative real-time polymerase chain reaction. This report emphasizes that transplant-acquired WNV neuroinvasive disease can be particularly severe. We suggest that pre-procurement screening of organ donors by testing blood with both WNV IgM capture ELISA and a sensitive nucleic acid testing should be adopted during the transmission season in the present Italian epidemiological setting.
Porto-Ferreira, Francisco Augusto; de Almeida-Neto, Cesar; Murphy, Edward L.; de Camargo Montebello, Sandra; Nogueira, Fátima Aparecida Hangai; Koga da Silva, Edina Mariko; MacFarland, William; Custer, Brian
2016-01-01
Introduction Low return rates for notification and counseling among donors with reactive serologic screening tests have been reported worldwide. A randomized trial to test the effectiveness of text message, letter or telephone call reminders to improve return among non-responding first-time blood donors with reactive serologic tests was conducted. Methods Donors with serologically reactive screening test results who had a cell phone and resided in the metropolitan telephone area code of São Paulo in the period from August 2013 through July 2014 were eligible. A consecutive sample of first-time donors with reactive screening tests who had not responded to a standard letter requesting the donor return to the blood center were randomly assigned to receive a text, a new letter or a telephone call requesting return for notification and counseling. Return rates were measured over the subsequent 30 days. Results Return following a phone call reminder was better than a text message (39.8% vs. 28.4%; OR=1.66; 95%CI 1.05–2.64) but not better than a letter (39.8% vs. 34.4%; OR=1.32; 95%CI 0.83–2.12). Older age was a predictor of higher rate of return with each year increase in age associated with a 2% increase in the odds of return (OR=1.02; 95%CI 1.01–1.04). Conclusion In non-responding serologic reactive donors, telephone call led to a higher return rate than text message. The results of this study suggest that use of text messages, while attractive for its simplicity, will not lead to increased donor notification success following serologically reactive marker results from blood donation in Brazil. PMID:27774609
Pallavi, P; Ganesh, C K; Jayashree, K; Manjunath, G V
2011-03-01
Blood is life. Transfusion of blood and blood components, as a specialized modality of patient management saves millions of lives worldwide each year and reduce morbidity. It is well known that blood transfusion is associated with a large number of complications, some are only trivial and others are potentially life threatening, demanding for meticulous pretransfusion testing and screening particularly for transfusion transmissible infections (TTI). These TTI are a threat to blood safety. The priority objective of BTS is thus to ensure safety, adequacy, accessibility and efficiency of blood supply at all levels. The objective of the present study was to assess the prevalence and trend of transfusion transmitted infections (TTI) among voluntary and replacement donors in the Department of Blood bank and transfusion Medicine of JSS College Hospital, a teaching hospital of Mysore during the period from 2004 to 2008. A retrospective review of donors record covering the period between 2004 and 2008 at the blood bank, JSS Hospital, Mysore was carried out. All samples were screened for HIV, HBsAg, HCV, syphilis and malaria. Of the 39,060, 25,303 (64.78%) were voluntary donors and the remaining 13,757 (35.22%) were replacement donors. The overall prevalence of HIV, HbsAg, HCV and syphilis were 0.44, 1.27, 0.23 and 0.28%, respectively. No blood donor tested showed positivity for malarial parasite. Majority were voluntary donors with male preponderance. In all the markers tested there was increased prevalence of TTI among the replacement donors as compared to voluntary donors. With the implementation of strict donor criteria and use of sensitive screening tests, it may be possible to reduce the incidence of TTI in the Indian scenario.
Heim, Albert
2016-01-01
Summary Background The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. Methods ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Results Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p < 0.001) which included non-heart-beating (‘cadaveric’) donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. Conclusion The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors. PMID:27403089
Kitchen, Alan D; Hewitt, Patricia E; Chiodini, Peter L
2012-09-01
Trypanosoma cruzi is a parasitic infection endemic in Central and Southern America, but is spreading into nonendemic countries with migration of infected individuals from endemic countries. The parasite is transmitted by transfusion or transplantation and donation screening is performed routinely in endemic countries to prevent transmission. In situations where migrants from endemic countries have settled in nonendemic countries and present as donors (blood or other cellular products), intervention is required to prevent transfusion or transplantation transmission. A screening program for T. cruzi was developed and has been used successfully for over 10 years that includes donor selection and donation screening. Donor selection criteria to identify specific risk of T. cruzi infection were developed together with laboratory screening of donations for T. cruzi antibodies and the subsequent confirmation of screen reactivity. Since the introduction of T. cruzi screening in England in 1998, a total of 38,585 donors and donations have been screened for T. cruzi antibodies, of which 223 were repeat reactive on screening and referred for confirmation: 206 confirmed negative, 14 inconclusive, and three positive. Since the move in 2005 from donor qualification to donation release testing, 15,536 donations were collected and screened, of which 15,499 (99.8%) were T. cruzi antibody negative and released to inventory. An effective program to minimize risk of the transmission of T. cruzi infection via donations has been developed and implemented. Not only does the program minimize risk of transmission, it also minimizes the cumulative, and needless, loss of donors and donations that would ensue if permanent donor deferral alone was adopted. © 2012 American Association of Blood Banks.
Kitchen, A D; Gillan, H L
2010-04-01
The overall effectiveness of the NHSBT screening programme for infectious agents in deceased tissue donors is examined and evaluated in terms of current outcomes and how to improve upon these outcomes. The screening results and any subsequent confirmatory results from a total of 1659 samples from NHSBT deceased donors referred to NTMRL for screening for infectious agents were included in the analysis. Overall 1566/1659 (94.4%) of the samples were screen negative. A total of 93 were repeat reactive on screening for one or more of the mandatory markers screened for, of which only 12 (13%) were subsequently confirmed to be positive on confirmatory testing. The majority of the repeat reactive samples were demonstrating non-specific reactivity with the screening assays in use. Overall, the NHSBT screening programme for infectious agents in deceased tissue donors is very effective with a relatively low overall loss of donors because of non-specific reactivity. However, unnecessary loss of tissue products is not acceptable, and although this programme compares favourably with the outcomes of other such programmes, the confirmatory results obtained demonstrate both the need and the potential for improving the outcomes. This is particularly important as one donor may donate more than one product, and can be achieved very easily with a change to the screening algorithm followed, using the confirmatory data obtained to support and validate this change. CONTENTS SUMMARY: Critical analysis of the NHSBT screening programme for infectious agents in deceased tissue donors and a strategy involving the design and use of a different screening algorithm to improve these outcomes.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... Virus From Donors of Human Cells, Tissues, and Cellular and Tissue-Based Products; Availability AGENCY... to Reduce the Risk of Transmission of West Nile Virus From Donors of Human Cells, Tissues, and... testing for West Nile Virus (WNV) using an FDA-licensed donor screening test. The guidance recommends the...
2010-01-01
Background Occult hepatitis B virus (HBV) infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg) testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. Methods A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT) for detection of occult HBV infection and surface gene was analyzed after direct sequencing. Results A total of 220 (30.1%) HBsAg negative donors were antiHBc positive, of them 66 (30%) were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3%) was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Conclusion Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India. PMID:20799931
Panigrahi, Rajesh; Biswas, Avik; Datta, Sibnarayan; Banerjee, Arup; Chandra, Partha K; Mahapatra, Pradip K; Patnaik, Bharat; Chakrabarti, Sekhar; Chakravarty, Runu
2010-08-27
Occult hepatitis B virus (HBV) infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg) testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT) for detection of occult HBV infection and surface gene was analyzed after direct sequencing. A total of 220 (30.1%) HBsAg negative donors were antiHBc positive, of them 66 (30%) were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3%) was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.
Keechilot, Cinzia S; Shenoy, Veena; Kumar, Anil; Biswas, Lalitha; Vijayrajratnam, Sukhithasri; Dinesh, Kavitha; Nair, Prem
With the introduction of highly sensitive hepatitis B surface antigen immunoassay, transfusion associated HBV infection have reduced drastically but they still tend to occur due to blood donors with occult hepatitis B infection (OBI) and window period (WP) infection. Sera from, 24338 healthy voluntary blood donors were screened for HBsAg, HIV and HCV antibody using Vitros Enhanced Chemiluminescent Immunoassay. The median age of the donor population was 30 (range 18-54) with male preponderance (98%). All serologically negative samples were screened by nucleic acid testing (NAT) for viral DNA and RNA. NAT-positive samples were subjected to discriminatory NAT for HBV, HCV, and HIV and all samples positive for HBV DNA were tested for anti-HBc, anti-HBs, HBeAg. Viral load was determined using artus HBV RG PCR Kit. Of the 24,338 donors screened, 99.81% (24292/24338) were HBsAg negative of which NAT was positive for HBV DNA in 0.0205% (5/24292) donors. Four NAT positive donors had viral load of <200 IU/ml making them true cases of OBI. One NAT positive donor was negative for all antibodies making it a case of WP infection. Among OBI donors, 75% (3/4) were immune and all were negative for HBeAg. Precise HBV viral load could not be determined in all (5/5) NAT positive donors due to viral loads below the detection limit of the artus HBV RG PCR Kit. The overall incidence of OBI and WP infections was found to be low at 1 in 6503 and 1 in 24214 donations, respectively. More studies are needed to determine the actual burden of WP infections in Indian blood donors.
Japhet, Margaret Oluwatoyin; Adewumi, Moses Olubusuyi; Adesina, Olufisayo Adeyemi; Donbraye, Emmanuel
2016-01-01
Blood transfusion service centers in Nigeria screen donated blood for markers of HIV infection using antibody- (Ab) based rapid test and in some centers, positives are re-tested using Ab-based ELISA. Paucity of data exists on p24 antigen prevalence among HIV Ab-negative donors in Nigeria. This study aims at detecting HIV p24 antigen among prospective blood donors in Osun State, Nigeria. Prospective blood donors negative for HIV antibodies using Determine test kit were re-tested using BIORAD GENSCREEN Ultra Ag-Ab ELISA kit, a fourth-generation ELISA kit that detects HIV antibodies/p24 antigen. Of the 169 HIV Ab-negative prospective donors, 10 (5.9%) were positive for HIV p24 antigen and 70% (7/10) of them were in the age range 18-30 years. Results of this study show that blood transfusion is still one of the major routes of HIV transmission in Nigeria and a higher proportion is among youth. Inclusion of p24 antigen testing into the blood donor screening will help reduce transfusion associated HIV in Nigeria if Nucleic Acid Testing (NAT) of all blood donor samples is not affordable; also, HIV enlightenment programs tailored toward youth may help reduce this rate among donors since more young people donate blood in low/middle-income countries than in high-income countries.
Chaudhary, Rajendra; Dubey, Anju; Sonker, Atul
2017-01-01
Blood donor hemoglobin (Hb) estimation is an important donation test that is performed prior to blood donation. It serves the dual purpose of protecting the donors' health against anemia and ensuring good quality of blood components, which has an implication on recipients' health. Diverse cutoff criteria have been defined world over depending on population characteristics; however, no testing methodology and sample requirement have been specified for Hb screening. Besides the technique, there are several physiological and methodological factors that affect accuracy and reliability of Hb estimation. These include the anatomical source of blood sample, posture of the donor, timing of sample and several other biological factors. Qualitative copper sulfate gravimetric method has been the archaic time-tested method that is still used in resource-constrained settings. Portable hemoglobinometers are modern quantitative devices that have been further modified to reagent-free cuvettes. Furthermore, noninvasive spectrophotometry was introduced, mitigating pain to blood donor and eliminating risk of infection. Notwithstanding a tremendous evolution in terms of ease of operation, accuracy, mobility, rapidity and cost, a component of inherent variability persists, which may partly be attributed to pre-analytical variables. Hence, blood centers should pay due attention to validation of test methodology, competency of operating staff and regular proficiency testing of the outputs. In this article, we have reviewed various regulatory guidelines, described the variables that affect the measurements and compared the validated technologies for Hb screening of blood donors along with enumeration of their merits and limitations.
Cadar, Daniel; Maier, Philipp; Müller, Susanne; Kress, Julia; Chudy, Michael; Bialonski, Alexandra; Schlaphof, Alexander; Jansen, Stephanie; Jöst, Hanna; Tannich, Egbert; Runkel, Stefan; Hitzler, Walter E; Hutschenreuter, Gabriele; Wessiepe, Martina; Schmidt-Chanasit, Jonas
2017-04-06
Between 1 June and 31 December 2016, 13,023 blood donations from the University Hospital Aachen in Germany were routinely screened for West Nile virus (WNV) RNA using the cobas TaqScreen WNV Test. On 28 September 2016, one blood donor was tested positive. Subsequent analysis revealed an acute Usutu virus (USUV) infection. During the ongoing USUV epizootics in Germany, blood transfusion services, public health authorities and clinicians should be aware of increased human USUV infections. This article is copyright of The Authors, 2017.
2014-01-01
Background Transfusion-transmitted infections are a major problem associated with blood transfusion. The aim of this study was to determine prevalence and trends of HBV, HCV and HIV in blood donors in Argentina. Methods A retrospective study was carried out in blood donors of 27 transfusion centers covering the whole country over a period of eight years (2004-2011). Serologic screening assays for HBsAg, anti-HBc, anti-HCV, and anti-HIV were performed in all centers and nucleic acid amplification testing (NAT) was performed in 2 out of the 27 centers. Results The 2,595,852 samples tested nationwide from 2004 to 2011 showed that the prevalence of HBsAg decreased from 0.336% to 0.198% (p < 0.0001), that of anti-HBc from 2.391% to 2.007% (p < 0.0001), that of anti-HCV from 0.721% to 0.460%, (p < 0.0001) and that of anti-HIV from 0.208% to 0.200 (p = 0.075). The prevalence of HBV, HCV and HIV was unevenly distributed among the different regions of the country. Two out of 74,838 screening- negative samples were positive in NAT assays (1 HIV-RNA and 1 HCV-RNA); moreover, HBV-DNA, HCV-RNA and HIV-RNA were detected in 60.29, 24.54 and 66.67% of screening-positive samples of the corresponding assays. As regards donors age, positive HBV-DNA and HCV-RNA donors were significantly older than healthy donors (46.6, 50.5 and 39.5 y respectively, p < 0.001). Conclusions Argentina has a low prevalence of HBsAg, anti-HCV and anti-HIV in blood donors, with a decreasing trend for HBsAg, anti-HBc and anti-HCV but not for anti-HIV over the last 8 years. The uneven distribution of transfusion-transmitted infections prevalence among the different regions of the country highlights the need to implement regional awareness campaigns and prevention. The discrepancy between samples testing positive for screening assays and negative for NAT assays highlights the problem of blood donors who test repeatedly reactive in screening assays but are not confirmed as positive upon further testing. The uneven distribution of age between healthy donors and NAT-positive donors could be related to changes in risks of these pathogens in the general population and might be attributed to a longer exposure to transmission risk factors in elderly people. PMID:24755089
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2012 CFR
2012-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2014 CFR
2014-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2013 CFR
2013-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening test for HBsAg); and (4) Hepatitis C (e.g., FDA licensed screening test for anti-HCV). (b) In the case... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
Kitchen, A D; Lowe, P H J; Lalloo, K; Chiodini, P L
2004-10-01
A new recombinant Plasmodium antigen enzyme immunoassay (EIA) for the detection of malarial antibodies was evaluated for the screening of 'malaria-risk' blood and tissue donations. A total of 13,269 donor and patient samples were tested by both the EIA and the standard diagnostic antibody immunofluorescence test (IFAT). A total of 114/138 (82.6%) samples from patients with P. falciparum and 11/13 (84.6%) samples from patients with P. vivax tested positive. A total of 714/13,053 (5.47%) samples from donors identified as 'malaria risk', owing to residency or travel, were reactive in the EIA. The assay is more sensitive than a previously implemented malarial antibody EIA (73% in acute P. falciparum and 56% in acute P. vivax infections). The sensitivity of this new EIA is comparable to that of the IFAT, and the specificity is sufficient to screen 'malaria-risk' donors.
Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H
1990-11-08
We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.
Thaikruea, Lakkana; Nantachit, Niwes; Leetrakool, Nipapan; Fongsatitkul, Ladda; Sompan, Prakai; Heaton, Andrew; Nelson, Kenrad E
2008-09-01
A self-deferral form has been used to screen Chiang Mai University Hospital blood donors and was improved in 2005. It has never been evaluated. The study aimed to assess the self-deferral form procedures in detecting infected donors. Sera from 5,083 donors, who passed the self-deferral screening form, were tested with the routine immuno-assays (serology) for HIV 1 and 2 antibodies, P24 antigen, HCV antibodies, HBV surface antigen, and syphilis. Antibody negative sera were also tested individually with the the Procleix Ultrio Assay for HIV-1 DNA, HCV RNA, and HBV DNA. The donors who had discrepant results between serology and NAT were evaluated with additional tests, including a more sensitive Alternative Nucleic Acid Test, AntiBcore IgM, AntiBcore IgG, HBsAg and Anti HBs. Among 5,083 donors, 331 (6.5%) had at least one positive marker. In multiple logistic regression analysis, the statistically significant factors (adjusted odds ratio and 95% CI) for infection were age 30 years or below [1.45 (1.03, 2.03)], male gender [2.73 (1.64, 4.56)], primary school or lower education [1.56 (1.09, 2.23)], first-time donation [1.82 (1.25, 2.67)], and frequent donation [0.80 (0.70, 0.92)]. The safest donors were females, older than 30 years, with an education more than primary school, and frequent donation. Because of missing responses to some sensitive questions, there remains a need for further improvement of the self-deferral form.
Donor's understanding of the definition of sex as applied to predonation screening questions.
O'Brien, S F; Ram, S S; Yi, Q-L; Goldman, M
2008-05-01
Predonation screening questions about sexual risk factors should provide an extra layer of safety from recently acquired infections that may be too early to be detected by testing. Donors are required to read a definition of sex as it applies to predonation screening questions each time they come to donate, but how well donors apply such definitions has not been evaluated. We aimed to determine how donors define sex when answering screening questions. In total, 1297 whole blood donors were asked in a private interview to select from a list of sexual activities which ones they believed were being asked about in sexual background questions. Donors' definitions were coded as under-inclusive, correct or over-inclusive in relation to the blood services' definition. Qualitative interviews were carried out with 21 donors to understand reasoning behind definitions. Most donors had an over-inclusive definition (58.7%) or the correct definition (31.9%). Of the 9.4% of donors who had an under-inclusive definition, 95% included both vaginal and anal sex, but not oral sex. About 9% in each group were first-time donors (P > 0.05) who had never read the definition. The qualitative interviews indicated that donors reason their definition based on their own concept of transmissible disease risk. Donors apply a range of definitions of sex when answering questions about their sexual background. This may be due to different concepts of risk activities, and required reading of the definition has little impact.
Elyamany, Ghaleb; Al Gharawi, Ali; Alrasheed, Mohammed; Alsuhaibani, Omar
2016-02-01
In Saudi Arabia, where malaria is not endemic, the incidence is very low. However, malaria transmission cases have been reported, mainly in Asir and Jazan provinces along the Southwestern border with Yemen. Imported cases also have been reported. The aims of this study were to determine the prevalence of malaria in blood donors in a tertiary care hospital in the central area of Saudi Arabia and to assess the effectiveness of malaria screening methods used by transfusion services in Prince Sultan Military Medical City. This study was conducted on 180,000 people who donated blood during 2006-2015. All blood smears from blood donors were screened for malaria infection using Giemsa staining, low power and high power microscopic examinations, and using oil immersion lens. The data were analyzed and reported in descriptive statistics and prevalence. From the total of 180,000 blood donors who were screened for malaria, 156,000 (87%) and 23.400 (13%) were Saudi Arabia citizens and non-Saudi residents, respectively. The mean age of the blood donors was 32 (ranging from 18 to 65), 97% and 3% were male and female, respectively. Using our current method for malaria screening, the prevalence of malaria in the study population was zero. The current methods of malaria screening in blood donors is not suitable for screening low-level parasiotemia. Adding the immunoassay and molecular screening methods is suggested.
Stephen, Selvaraj; Pradeep, Jothimani; Anitharaj, Velmurugan; Janarthanam, Venkatraman
2017-12-01
Our objective is to study the seroprevalence of toxoplasmosis in the voluntary blood donors of Puducherry and surrounding districts of Tamil Nadu. A total of 275 healthy blood donors were screened for the presence of IgM and IgG antibodies to Toxoplasma gondii by ELISA test. Donor samples positive for IgM and/or IgG antibodies to T. gondii were subjected to IgG avidity ELISA. While, 54 out of 275 donors had IgG antibodies (19.66%), only one donor had IgM (0.36%) along with IgG. Among 54 IgG positive donors, only two had low avidity (3.7%), indicating recent exposure to the protozoa. Feasibility and cost effectiveness studies should be conducted throughout India to decide regarding screening of blood donors for toxoplasmosis.
Risk for transfusion-transmitted infectious diseases in Central and South America.
Schmunis, G A; Zicker, F; Pinheiro, F; Brandling-Bennett, D
1998-01-01
We report the potential risk for an infectious disease through tainted transfusion in 10 countries of South and Central America in 1993 and in two countries of South America in 1994, as well as the cost of reagents as partial estimation of screening costs. Of the 12 countries included in the study, nine screened all donors for HIV; three screened all donors for hepatitis B virus (HBV); two screened all donors for Trypanosoma cruzi; none screened all donors for hepatitis C virus (HCV); and six screened some donors for syphilis. Estimates of the risk of acquiring HIV through blood transfusion were much lower than for acquiring HBV, HCV, or T. cruzi because of significantly higher screening and lower prevalence.rates for HIV. An index of infectious disease spread through blood transfusion was calculated for each country. The highest value was obtained for Bolivia (233 infections per 10,000 transfusions); in five other countries, it was 68 to 103 infections per 10,000. The risks were lower in Honduras (nine per 10,000), Ecuador (16 per 10,000), and Paraguay (19 per 10,000). While the real number of potentially infected units or infected persons is probably lower than our estimates because of false positives and already infected recipients, the data reinforce the need for an information system to assess the level of screening for infectious diseases in the blood supply. Since this information was collected, Chile, Colombia, Costa Rica, and Venezuela have made HCV screening mandatory; serologic testing for HCV has increased in those countries, as well as in El Salvador and Honduras. T. cruzi screening is now mandatory in Colombia, and the percentage of screened donors increased not only in Colombia, but also in Ecuador, El Salvador, and Paraguay. Laws to regulate blood transfusion practices have been enacted in Bolivia, Guatemala, and Peru. However, donor screening still needs to improve for one or more diseases in most countries.
Risk for transfusion-transmitted infectious diseases in Central and South America.
Schmunis, G. A.; Zicker, F.; Pinheiro, F.; Brandling-Bennett, D.
1998-01-01
We report the potential risk for an infectious disease through tainted transfusion in 10 countries of South and Central America in 1993 and in two countries of South America in 1994, as well as the cost of reagents as partial estimation of screening costs. Of the 12 countries included in the study, nine screened all donors for HIV; three screened all donors for hepatitis B virus (HBV); two screened all donors for Trypanosoma cruzi; none screened all donors for hepatitis C virus (HCV); and six screened some donors for syphilis. Estimates of the risk of acquiring HIV through blood transfusion were much lower than for acquiring HBV, HCV, or T. cruzi because of significantly higher screening and lower prevalence.rates for HIV. An index of infectious disease spread through blood transfusion was calculated for each country. The highest value was obtained for Bolivia (233 infections per 10,000 transfusions); in five other countries, it was 68 to 103 infections per 10,000. The risks were lower in Honduras (nine per 10,000), Ecuador (16 per 10,000), and Paraguay (19 per 10,000). While the real number of potentially infected units or infected persons is probably lower than our estimates because of false positives and already infected recipients, the data reinforce the need for an information system to assess the level of screening for infectious diseases in the blood supply. Since this information was collected, Chile, Colombia, Costa Rica, and Venezuela have made HCV screening mandatory; serologic testing for HCV has increased in those countries, as well as in El Salvador and Honduras. T. cruzi screening is now mandatory in Colombia, and the percentage of screened donors increased not only in Colombia, but also in Ecuador, El Salvador, and Paraguay. Laws to regulate blood transfusion practices have been enacted in Bolivia, Guatemala, and Peru. However, donor screening still needs to improve for one or more diseases in most countries. PMID:9452393
21 CFR 610.41 - Donor deferral.
Code of Federal Regulations, 2012 CFR
2012-04-01
... §§ 610.46 and 610.47 when a donor tests reactive by a screening test for HIV or HCV required under § 610... evidence of HIV or HCV infection. [66 FR 31164, June 11, 2001, as amended at 72 FR 48798, Aug. 24, 2007] ...
21 CFR 610.41 - Donor deferral.
Code of Federal Regulations, 2014 CFR
2014-04-01
... §§ 610.46 and 610.47 when a donor tests reactive by a screening test for HIV or HCV required under § 610... evidence of HIV or HCV infection. [66 FR 31164, June 11, 2001, as amended at 72 FR 48798, Aug. 24, 2007] ...
21 CFR 610.41 - Donor deferral.
Code of Federal Regulations, 2011 CFR
2011-04-01
... §§ 610.46 and 610.47 when a donor tests reactive by a screening test for HIV or HCV required under § 610... evidence of HIV or HCV infection. [66 FR 31164, June 11, 2001, as amended at 72 FR 48798, Aug. 24, 2007] ...
21 CFR 610.41 - Donor deferral.
Code of Federal Regulations, 2013 CFR
2013-04-01
... §§ 610.46 and 610.47 when a donor tests reactive by a screening test for HIV or HCV required under § 610... evidence of HIV or HCV infection. [66 FR 31164, June 11, 2001, as amended at 72 FR 48798, Aug. 24, 2007] ...
A pilot study on screening blood donors with individual-donation nucleic acid testing in China
Dong, Jie; Wu, Yaling; Zhu, Hong; Li, Gan; Lv, Mengen; Wu, Daxiao; Li, Xiaotao; Zhu, Faming; Lv, Hangjun
2014-01-01
Background Nucleic acid amplification testing (NAT) is not yet obligatory in China for blood donor screening and the risk of enzyme immunoassay (EIA)-negative, NAT-reactive donations in Chinese blood donors has rarely been reported. The aim of this study was to screen a population of Chinese blood donors using a triplex individual-donation (ID)-NAT assay and assess the safety benefits of implementing NAT. Materials and methods Between 1st August, 2010 and 31st December, 2011 all donations at a Chinese blood centre were screened individually using the Procleix® Ultrio® assay, a multiplex NAT assay for the detection of hepatitis B virus (HBV) DNA, hepatitis C virus (HCV) RNA and human immunodeficiency virus-1 (HIV-1) RNA. All donations were also screened for HBsAg, anti-HIV and anti-HCV using two different EIA for each marker. Samples with discordant results between NAT and EIA were further tested with an alternative NAT assay (Cobas® TaqMan®). Potential yield cases (serologically negative/NAT-reactive donors) were further evaluated when possible. Results During the study period a total of 178,447 donations were screened by NAT and EIA, among which 169 HBV NAT yield cases (0.095%) were detected. No N AT yield cases were found for HIV-1 or HCV. For the HBV NAT yield cases, follow-up results showed that 11 (6.51%) were probable or confirmed HBV window period infections, 5 (2.96%) were chronic HBV carriers and 153 (90.53%) were probable or confirmed occult HBV infections. There was a statistically significant difference between the NAT-positive rates for first-time vs repeat donations (0.472% vs 0.146%, respectively; P<0.001). Discussion Our data demonstrate that the potential HBV yield rate was 1:1,056 for blood donations in the Zhejiang province of China. Implementation of NAT will provide a significant increment in safety relative to serological screening alone. PMID:24333061
Enabling multiplexed testing of pooled donor cells through whole-genome sequencing.
Chan, Yingleong; Chan, Ying Kai; Goodman, Daniel B; Guo, Xiaoge; Chavez, Alejandro; Lim, Elaine T; Church, George M
2018-04-19
We describe a method that enables the multiplex screening of a pool of many different donor cell lines. Our method accurately predicts each donor proportion from the pool without requiring the use of unique DNA barcodes as markers of donor identity. Instead, we take advantage of common single nucleotide polymorphisms, whole-genome sequencing, and an algorithm to calculate the proportions from the sequencing data. By testing using simulated and real data, we showed that our method robustly predicts the individual proportions from a mixed-pool of numerous donors, thus enabling the multiplexed testing of diverse donor cells en masse.More information is available at https://pgpresearch.med.harvard.edu/poolseq/.
Screening for Babesia microti in the U.S. Blood Supply.
Moritz, Erin D; Winton, Colleen S; Tonnetti, Laura; Townsend, Rebecca L; Berardi, Victor P; Hewins, Mary-Ellen; Weeks, Karen E; Dodd, Roger Y; Stramer, Susan L
2016-12-08
Babesia microti, a tickborne intraerythrocytic parasite that can be transmitted by means of blood transfusion, is responsible for the majority of cases of transfusion-transmitted babesiosis in the United States. However, no licensed test exists for screening for B. microti in donated blood. We assessed data from a large-scale, investigational product-release screening and donor follow-up program. From June 2012 through September 2014, we performed arrayed fluorescence immunoassays (AFIAs) for B. microti antibodies and real-time polymerase-chain-reaction (PCR) assays for B. microti DNA on blood-donation samples obtained in Connecticut, Massachusetts, Minnesota, and Wisconsin. We determined parasite loads with the use of quantitative PCR testing and assessed infectivity by means of the inoculation of hamsters and the subsequent examination for parasitemia. Donors with test-reactive samples were followed. Using data on cases of transfusion-transmitted babesiosis, we compared the proportions of screened versus unscreened donations that were infectious. Of 89,153 blood-donation samples tested, 335 (0.38%) were confirmed to be positive, of which 67 (20%) were PCR-positive; 9 samples were antibody-negative (i.e., 1 antibody-negative sample per 9906 screened samples), representing 13% of all PCR-positive samples. PCR-positive samples were identified all through the year; antibody-negative infections occurred from June through September. Approximately one third of the red-cell samples from PCR-positive or high-titer AFIA-positive donations infected hamsters. Follow-up showed DNA clearance in 86% of the donors but antibody seroreversion in 8% after 1 year. In Connecticut and Massachusetts, no reported cases of transfusion-transmitted babesiosis were associated with screened donations (i.e., 0 cases per 75,331 screened donations), as compared with 14 cases per 253,031 unscreened donations (i.e., 1 case per 18,074 unscreened donations) (odds ratio, 8.6; 95% confidence interval, 0.51 to 144; P=0.05). Overall, 29 cases of transfusion-transmitted babesiosis were linked to blood from infected donors, including blood obtained from 10 donors whose samples tested positive on the PCR assay 2 to 7 months after the implicated donation. Blood-donation screening for antibodies to and DNA from B. microti was associated with a decrease in the risk of transfusion-transmitted babesiosis. (Funded by the American Red Cross and Imugen; ClinicalTrials.gov number, NCT01528449 .).
Stramer, Susan L; Townsend, Rebecca L; Foster, Gregory A; Johnson, Ramona; Weixlmann, Barbara; Dodd, Roger Y
2018-03-01
Human T-lymphotropic virus (HTLV) blood donation screening has used a dual-testing algorithm beginning with either a chemiluminescent immunoassay or enzyme-linked immunosorbent screening assay (ELISA). Before the availability of a licensed HTLV supplemental assay, repeat-reactive (RR) samples on a first assay (Assay 1) were retested with a second screening assay (Assay 2). Donors with RR results by Assay 2 were deferred from blood donation and further tested using an unlicensed supplemental test to confirm reactivity while nonreactive (NR) donors remained eligible for donation until RR on a subsequent donation. This "dual-test" algorithm was replaced in May 2016 with the requirement that all RRs by Assay 1 be further tested by a licensed HTLV supplemental test (Western blot [WB]). In this study, we have requalified the dual-test algorithm using the available licensed HTLV WB. We tested 100 randomly selected HTLV RRs on screening Assay 1 (Abbott PRISM chemiluminescent immunoassay) but NR on screening Assay 2 (Avioq ELISA) by a Food and Drug Administration-licensed WB (MP Biomedicals) to ensure that no confirmed positives were among those that were RR by Assay 1 but NR by Assay 2. Of the 100 samples evaluated, 79 of 100 were WB seronegative, 21 of 100 indeterminate, and 0 of 100 seropositive. Of the 79 of 100 seronegative specimens, 73 of 79 did not express any bands on WB. We demonstrated that none of the 100 samples RR on Assay 1 but NR on Assay 2 were confirmed positive. This algorithm prevents such donors from requiring further testing and from being deferred. © 2018 AABB.
Kaur, Daljit; Bains, Lovenish; Kandwal, Manoj; Parmar, Indu
2017-03-01
The ultimate aim of pretransfusion testing is the acceptable survival of donor red cells in recipient's body and antibody detection plays a critical role in achieving the same. The cornerstone of antibody detection method is detecting an unexpected antibody as against the expected antibodies of ABO blood group system. Autoantibodies can also interfere with the detection of clinically significant alloantibodies. To study the frequency of alloantibodies and autoantibodies in the healthy blood donors and patient population visiting our hospital. The Column Agglutination Technology (CAT) was used for ABO RhD blood grouping, Direct Antiglobulin Test (DAT), Autocontrol (AC), Indirect Antiglobulin Test (IAT) and red cell antibody screening and the unexpected reactions in any of these tests were recorded for further evaluation. Ethylene Diamine Tetra Acetic Acid (EDTA) blood samples were used for all these tests for both blood donors and admitted patients. The CAT was exercised for the blood grouping (using ABD-Reverse Diluent cassettes) and antibody screening (using 0.8% Surgiscreen, Ortho Clinical Diagnostics Limited, USA and Low Ionic Strength Saline Ortho BLISS with AHG cassettes) on the automated immunohaematology platform ORTHO AutoVue ® Innova system (Ortho Clinical Diagnostics Limited, USA). Among all blood donors (n=6350), seven (0.11%) donors had showed unexpected reaction. Of these, four had positive antibody screen (three having naturally occuring antibodies 2=anti-M, 1=anti-Le a and 1=inconclusive) and the other three had positive DAT. Of all the patient samples (n=6136) screened for irregular red cell antibodies, four (0.06%) patients were found to have unexpected reaction revealing one (0.02%) with anti-M antibody and the other three (0.05%) had autoantibodies in their serum. The combined prevalence for both blood donor and recipient population (n=12,486) was found to be 0.11% at our center. The alloimmunisation among patient population was found to be lower than many other studies worldwide as our hospital does not cater to multitransfused or transfusion dependant patients with haematological disorders and majorly elective surgery patients with no history of previous blood transfusions visit our hospital.
Bains, Lovenish; Kandwal, Manoj; Parmar, Indu
2017-01-01
Introduction The ultimate aim of pretransfusion testing is the acceptable survival of donor red cells in recipient’s body and antibody detection plays a critical role in achieving the same. The cornerstone of antibody detection method is detecting an unexpected antibody as against the expected antibodies of ABO blood group system. Autoantibodies can also interfere with the detection of clinically significant alloantibodies. Aim To study the frequency of alloantibodies and autoantibodies in the healthy blood donors and patient population visiting our hospital. Materials and Methods The Column Agglutination Technology (CAT) was used for ABO RhD blood grouping, Direct Antiglobulin Test (DAT), Autocontrol (AC), Indirect Antiglobulin Test (IAT) and red cell antibody screening and the unexpected reactions in any of these tests were recorded for further evaluation. Ethylene Diamine Tetra Acetic Acid (EDTA) blood samples were used for all these tests for both blood donors and admitted patients. The CAT was exercised for the blood grouping (using ABD-Reverse Diluent cassettes) and antibody screening (using 0.8% Surgiscreen, Ortho Clinical Diagnostics Limited, USA and Low Ionic Strength Saline Ortho BLISS with AHG cassettes) on the automated immunohaematology platform ORTHO AutoVue® Innova system (Ortho Clinical Diagnostics Limited, USA). Results Among all blood donors (n=6350), seven (0.11%) donors had showed unexpected reaction. Of these, four had positive antibody screen (three having naturally occuring antibodies 2=anti-M, 1=anti-Lea and 1=inconclusive) and the other three had positive DAT. Of all the patient samples (n=6136) screened for irregular red cell antibodies, four (0.06%) patients were found to have unexpected reaction revealing one (0.02%) with anti-M antibody and the other three (0.05%) had autoantibodies in their serum. Conclusion The combined prevalence for both blood donor and recipient population (n=12,486) was found to be 0.11% at our center. The alloimmunisation among patient population was found to be lower than many other studies worldwide as our hospital does not cater to multitransfused or transfusion dependant patients with haematological disorders and majorly elective surgery patients with no history of previous blood transfusions visit our hospital. PMID:28511387
Ismail, Sohal Y; Duerinckx, Nathalie; van der Knoop, Marieke M; Timmerman, Lotte; Weimar, Willem; Dobbels, Fabienne; Massey, Emma K; Busschbach, Jan J J V
2015-11-01
Across Europe, transplant centers vary in the content of the psychosocial evaluation for eligible living organ donors. To identify whether a common framework underlies this variation in this evaluation, we studied which psychosocial screening items are most commonly used and considered as most important in current psychosocial screening programs of living organ donors. A multivariate analytic method, concept mapping, was used to generate a visual representation of the "psychosocial" screening items of living kidney and liver donors. A list of 75 potential screening items was derived from a systematic literature review and sorted and rated for their importance and commonness by multidisciplinary affiliated health care professionals from across Europe. Results were discussed and fine-tuned during a consensus meeting. The analyses resulted in a 6-cluster solution. The following clusters on psychosocial screening items were identified, listed from most to least important: (1) personal resources, (2) motivation and decision making, (3) psychopathology, (4) social resources, (5) ethical and legal factors, and (6) information and risk processing. We provided a conceptual framework of the essential elements in psychosocial evaluation of living donors which can serve as a uniform basis for the selection of relevant psychosocial evaluation tools, which can be further tested in prospective studies.
Cost-effectiveness of additional blood screening tests in the Netherlands.
Borkent-Raven, Barbara A; Janssen, Mart P; van der Poel, Cees L; Bonsel, Gouke J; van Hout, Ben A
2012-03-01
During the past decade, blood screening tests such as triplex nucleic acid amplification testing (NAT) and human T-cell lymphotropic virus type I or I (HTLV-I/II) antibody testing were added to existing serologic testing for hepatitis B virus (HBV), human immunodeficiency virus (HIV), and hepatitis C virus (HCV). In some low-prevalence regions these additional tests yielded disputable benefits that can be valuated by cost-effectiveness analyses (CEAs). CEAs are used to support decision making on implementation of medical technology. We present CEAs of selected additional screening tests that are not uniformly implemented in the EU. Cost-effectiveness was analyzed of: 1) HBV, HCV, and HIV triplex NAT in addition to serologic testing; 2) HTLV-I/II antibody test for all donors, for first-time donors only, and for pediatric recipients only; and 3) hepatitis A virus (HAV) for all donations. Disease progression of the studied viral infections was described in five Markov models. In the Netherlands, the incremental cost-effectiveness ratio (ICER) of triplex NAT is €5.20 million per quality-adjusted life-year (QALY) for testing minipools of six donation samples and €4.65 million/QALY for individual donation testing. The ICER for anti-HTLV-I/II is €45.2 million/QALY if testing all donations, €2.23 million/QALY if testing new donors only, and €27.0 million/QALY if testing blood products for pediatric patients only. The ICER of HAV NAT is €18.6 million/QALY. The resulting ICERs are very high, especially when compared to other health care interventions. Nevertheless, these screening tests are implemented in the Netherlands and elsewhere. Policy makers should reflect more explicit on the acceptability of costs and effects whenever additional blood screening tests are implemented. © 2011 American Association of Blood Banks.
Human immunodeficiency virus test-seeking blood donors in a large blood bank in São Paulo, Brazil.
Goncalez, Thelma; Sabino, Ester; Sales, Nanci; Chen, Yea-Hung; Chamone, Dalton; Busch, Michael; Murphy, Edward; Custer, Brian; McFarland, Willi
2010-08-01
Persons with human immunodeficiency virus (HIV) risk behaviors are excluded from donation to reduce the risk of transfusion-transmitted infection. Persons donating to be tested for HIV may therefore deny risk behaviors. A random sample of donors completed a survey on motivations, knowledge, and attitudes on the screening process. Donors were considered test seekers if they agreed with two statements "I think that blood donation is a good, fast, and anonymous way to get my blood tested" and "I donate to get my test results." This study was conducted from June to November 2006 at the largest blood bank in São Paulo, Brazil. Of 3061 participants, 208 (7%) were test seekers. They tended to be male and had a lower educational level. They were more likely to have incorrect knowledge about blood safety (e.g., not knowing that a unit can test antibody negative and still transmit infection, 50% vs. 42%, p = 0.02), express dissatisfaction with screening questions (e.g., feeling that important questions were not asked, 14% vs. 5%, p < 0.01), and concur that donors do not answer questions truthfully (e.g., donors have more sexual partners than they admit, 29% vs. 18%, p < 0.01). Test seekers were more likely to believe that it is acceptable to donate blood to get tested for HIV (41% vs. 10%, p < 0.01). Test-seeking motivation, coupled with low knowledge of window period risk, is counter to improving blood safety and to donor prevention needs. Donor education needs to be improved along with availability of appropriate HIV counseling and testing. © 2010 American Association of Blood Banks.
Point of care hemoglobin testing in plateletpheresis donors: Noninvasive versus invasive methods.
Mallhi, R S; Pawar, Amit; Kushwaha, Neerja; Kumar, Sudeep; Dimri, Ujjwal
2016-10-01
Predonation hemoglobin (Hb) for plateletpheresis donors is estimated by presently available invasive methods. Venous samples of only those donors whose Hb is more than 12.5 g/dl are screened for complete blood count and transfusion transmissible infections. There is a pressing need to substitute this invasive Hb test with noninvasive one to reduce donor discomfort and avoid further pricking the donor. We therefore went ahead with the aim of comparing a noninvasive Hb estimation method NBM 200 with the invasive method - Hemocue, taking SYSMEX KX-21 as a gold standard. 500 voluntary consenting plateletpheresis donors qualifying the laid down criteria for platelet donation were included in the study. Hb readings obtained by the NBM 200 and Hemocue were compared to those obtained from the fully automated hematology analyzer SYSMEX KX-21. Coefficients of correlation were found to be statistically significant at <0.0001 level of confidence. Results of Friedman's test on the three methods also showed significant difference in means. Bland-Altman plots and mountain plots also confirm the same. NBM 200 was found to be more sensitive, specific, and precise than Hemocue in detecting ineligible donors. NBM 200 was found to be more sensitive, specific, and precise as compared to Hemocue for predonation screening of Hb in plateletpheresis donors and the prime benefit it offers is that it is 'noninvasive' thereby assisting in stemming the platelet donor pool. The onus lies on the blood transfusion services to make use of appropriately validated gadgets that reduce the donor discomfort.
La Prairie, A J; Gross, M
1991-02-01
The banking of femoral heads from patients who undergo total hip arthroplasty provides a valuable resource for orthopedic surgery. Quality assurance of the banked bone used in clinical procedures requires documented policies for screening, procuring, storing and distributing. Potential donors are screened at the time of donation for malignant disease, possible communicable disease, sepsis and high-risk life-styles. After negative culture results are confirmed and appropriate documentation has been completed, the bone is frozen at -70 degrees C. A quarantine period of 90 days follows. The donor is followed up 90 days or more postoperatively. At that time written consent is obtained for donation of the recovered tissue to the bone bank and for serology testing for human immunodeficiency virus (HIV-1) antibody, hepatitis B surface antigen (HBsAG), hepatitis B core antibody (HBcAb) and syphilis, and the donor is rescreened for contraindications. This protocol meets or exceeds all existing standards. The combination of obtaining consent and serology testing at 90 days streamlines the logistics of banking bone from surgical donors.
Grégoire, Y; Germain, M; Delage, G
2018-05-01
Since 25 May 2010, all donors at our blood centre who tested false-positive for HIV, HBV, HCV or syphilis are eligible for re-entry after further testing. Donors who have a second false-positive screening test, either during qualification for or after re-entry, are deferred for life. This study reports on factors associated with the occurrence of such deferrals. Rates of second false-positive results were compared by year of deferral, transmissible disease marker, gender, age, donor status (new or repeat) and testing platform (same or different) both at qualification for re-entry and afterwards. Chi-square tests were used to compare proportions. Cox regression was used for multivariate analyses. Participation rates in the re-entry programme were 42·1%: 25·6% failed to qualify for re-entry [different platform: 2·7%; same platform: 42·9% (P < 0·0001)]. After re-entry, rates of deferral for second false-positive results were 8·4% after 3 years [different platform: 1·8%; same platform: 21·4% (P < 0·0001)]. Deferral rates were higher for HIV and HCV than for HBV at qualification when tested on the same platform. The risk, when analysed by multivariate analyses, of a second deferral for a false-positive result, both at qualification and 3 years after re-entry, was lower for donors deferred on a different platform; this risk was higher for HIV, HCV and syphilis than for HBV and for new donors if tested on the same platform. Re-entry is more often successful when donors are tested on a testing platform different from the one on which they obtained their first false-positive result. © 2018 International Society of Blood Transfusion.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-28
... Hepatitis B Virus AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug... Risk of Transmission of Hepatitis B Virus (HBV), and Requalification of Donors Who Test HBV NAT...-licensed nucleic acid tests (NAT) to screen blood donors for hepatitis B virus (HBV) deoxyribonucleic acid...
Parameters of infection in replacement and voluntary donors in the western part of Turkey.
Uzun, Berrin; Gungor, Serdar; Demirci, Mustafa
2014-08-01
According to our center's experiences familial/replacement donors (FRDs) frequently donate blood for the first time in their lives. Therefore, results of infection parameters are expected to be different voluntary donors (VDs), at similar rates to the population. The present study aimed to investigate if there were any difference in VDs and FRDs in terms of infection parameters. The blood donation records over 6 years (2004-2010) were reviewed, retrospectively. HBsAg, anti-HCV, anti-HIV screening tests were performed by ELISA and syphilis screening was performed by the RPR method. Out of 71.217, 16.727 donors donated whole blood as FRD. Among the whole blood donated by FRD, the positives for HBsAg, anti-HCV and RPR were 1.23%, 0.37%, and 0.07%, respectively. Confirmed anti-HIV screening test was not observed in this group. Positivities for HBsAg, anti-HCV, anti-HIV and RPR in VD were 1.36%, 0.42%, 0.004%, and 0.04%, respectively. When FRD and VD were analyzed statistically, HBsAg rates were significantly higher among FRD in the years 2004, 2007 and 2008, whereas they were significantly high among VD in year 2005. HBsAg rates stated in the years 2006-2009 were insignificant. Significantly high results were observed in HCV rates in the year 2005 among VD, whereas insignificant levels were observed in other years. HIV rates were insignificant among VD in the years 2004 and 2005, confirmed positivity was established in only one patient. Values in all years in RPR rates were statistically insignificant. Grouping donors as replacement and voluntary has no importance in infection parameters. Grouping donors as replacement and voluntary has no importance in infection parameters. Appropriate donor inquiries and screening of infection parameters by reliable proven tests preserve their significances. Copyright © 2014 Elsevier Ltd. All rights reserved.
Infectious agent screening in canine blood donors in the United Kingdom.
Crawford, K; Walton, J; Lewis, D; Tasker, S; Warman, S M
2013-08-01
Transfusion of blood products is an important component of veterinary emergency medicine. Donors must be carefully selected to minimise risk of transmission of blood-borne infectious agents. This study was devised to assess the prevalence of such agents in healthy, non-travelled UK dogs screened as prospective donors. Ethylenediaminetetraacetic acid blood samples from dogs donating blood between August 2007 and January 2012 were screened by polymerase chain reaction for haemotropic mycoplasmas, Bartonella, Babesia, Leishmania, Ehrlichia and Anaplasma spp. Dogs with positive or inconclusive results underwent repeat polymerase chain reaction testing. Four of 262 dogs had positive or inconclusive results at initial screening. Repeat polymerase chain reaction testing in each dog was negative, and none of the dogs developed clinical signs of disease. The positive results on initial screening may have represented false positives from sample contamination or amplification of non-target DNA. It is also possible that dogs were infected at initial sampling but successfully cleared infection before repeat testing. The low number of positive results obtained suggests that prevalence of these agents in a population of healthy UK dogs is low and that use of blood products is unlikely to represent a significant risk of transmission of these diseases. © 2013 British Small Animal Veterinary Association.
Wang, Jingxing; Liu, Jing; Yao, Fuzhu; Wen, Guoxin; Li, Julin; Huang, Yi; Lv, Yunlai; Wen, Xiuqiong; Wright, David; Yu, Qilu; Guo, Nan; Ness, Paul; Shan, Hua
2012-01-01
Background There is little data on HIV prevalence, incidence or residual risks for transfusion transmitted HIV infection among Chinese blood donors. Methods Donations from five Chinese blood centers in 2008–2010 were screened using two rounds of ELISA testing for anti-HIV-1/2. A reactive result in either or both rounds led to Western Blot confirmatory testing. HIV prevalence and demographic correlates among first time donors, incidence rate and demographic correlates among repeat donors were examined. Weighted multivariable logistic regression analysis examined correlates of HIV confirmatory status among first time donors. Residual risks for transfusion transmitted HIV infection were evaluated based on incidence among repeat donors. Results Among 821,320 donations, 40% came from repeat donors.1,837 (0.34%) first time and 577 (0.17%) repeat donations screened reactive for anti-HIV-1/2, among which 1,310 and 419 were tested by Western Blot. 233 (17.7%) first time and 44 (10.5%) repeat donations were confirmed positive. Estimated prevalence was 66 infections per 100,000 (95% CI: 59–74) first time donors. Estimated incidence was 9/100,000 (95% CI: 7–12) person-years among repeat donors. Weighted multivariable logistic regression analysis indicate that first time donors 26–45 years old were 1.6–1.8 times likely to be HIV positive than those 25 years and younger. Donors with some college or above education were less likely to be HIV positive than those with middle school education, ORs ranging from 0.35 to 0.60. Minority were 1.6 times likely to be HIV positive than Han majority donors (OR: 1.6; CI: 1.2–2.1). No difference in prevalence was found between gender. Current HIV TTI residual risk was 5.4 (1.2–12.5) infections per million whole blood donations. Conclusion Despite the declining HIV epidemic China, estimated residual risks for transfusion transmitted HIV infection are still high, highlighting the potential blood safety yield of NAT implementation in donation screening. PMID:23113801
Screening for sexually transmitted infection pathogens in semen samples
Peeling, RW; Embree, J
2005-01-01
The transmission of sexually transmitted infection (STI) pathogens from an infected donor to the recipient of a semen donation in assisted conception may result not only in acute infection but also in long-term reproductive complications or adverse outcomes of pregnancy, including infection of the offspring. Screening for bacterial STI pathogens, Chlamydia trachomatis and Neisseria gonorrhoeae is strongly recommended because these pathogens can cause serious reproductive complications in the recipients of semen donations and infection in their offspring. Screening for these pathogens should be performed using the most sensitive methods, such as nucleic acid amplified tests. False-negative results due to inhibitory substances in the semen sample should be monitored using amplification controls. Where specimen transport is not a problem and culture facilities are available, N gonorrhoeae can also be detected by culture. Laboratories performing screening should subscribe to proficiency programs and have strict quality controls. Although Trichomonas vaginalis, group B streptococcus and genital mycoplasmas have been associated with adverse outcomes of pregnancy, the frequent finding of these organisms in healthy individuals brings into question the validity of mandatory inclusion of these organisms in the screening panel. Although viral STI pathogens and Treponema pallidum - the causative agent of syphilis - may be detected in semen, their presence may be more sensitively detected through antibody testing of the donor. Screening donors for HIV, hepatitis B and syphilis by serology is uniformly recommended in all of the guidelines, but the value of screening either donors or semen samples for cytomegalovirus, herpes simplex viruses and human papilloma viruses is less clear. PMID:18159531
Preserving the national blood supply.
Brittenham, G M; Klein, H G; Kushner, J P; Ajioka, R S
2001-01-01
This paper examines the current state of the blood supply in the US and focuses on the potential for augmenting blood availability by attention to the iron status of donors. Increasing demands are being made upon the national blood supply as rates of blood donation are declining, in part because of the loss of blood donors as a result of enhanced screening and testing procedures. Iron-related means of expanding the blood supply include the use of blood from individuals undergoing therapeutic phlebotomy for hereditary hemochromatosis and enhancing the retention and commitment of women of childbearing age as donors by using iron supplementation to prevent iron deficiency. In Section I, Dr. Klein discuss the circumstances responsible for a decline in the population of eligible donors, including public attitudes toward donation, factors influencing the retention of donors by blood centers, and the effects of increased screening and testing to maintain the safety of the blood supply. In Section II, Drs. Kushner and Ajioka focus on the consequences of the decision by the US Food and Drug Administration (FDA) to develop recommendations to permit blood centers to collect blood from patients with hereditary hemochromatosis and to distribute this blood obtained without disease labeling if all other screening and testing procedures are passed. After summarizing the pathophysiology of hereditary hemochromatosis, the use by blood centers of blood obtained from heterozygotes and homozygotes for hereditary hemochromatosis is considered. In Section III, Dr. Brittenham reviews the use of low dose, short-term carbonyl iron supplementation for women donors of childbearing age. Replacing the iron lost at donation can help prevent iron deficiency in women of childbearing age and, by decreasing deferral, enhance the retention and commitment of women who give blood regularly. He emphasizes the use by blood centers of iron-related means to enhance recruitment and retention of blood donors.
Bernvil, S S; Andrews, V; Kuhns, M C; McNamara, A L
1997-03-01
Blood donor screening for anti-hepatitis B core antigen (anti-HBc) was introduced as a surrogate marker of non-A, non-B hepatitis prior to the availability of a specific test for hepatitis C. In areas endemic for hepatitis B virus (HBV), such as Saudi Arabia, earlier studies indicated that up to 30% of blood donors might disqualify if screened for anti-HBc. The issue was readdressed in a study of 6035 consecutive first-time Saudi national blood donors in an attempt to identify a subgroup of anti-HBc positive donors who might be at high risk of being low grade carriers of HBV. An isolated anti-HBc of high titer in a donor with a low or absent anti-hepatitis B surface antigen (anti-HBsAg) was taken as an indicator of increased risk of a low grade carrier state. Using this algorithm, an additional 125 (2%) donors would disqualify. HBsAg immune complex assays and polymerase chain reaction of donor samples with an isolated anti-HBc identified two donors with immune complexes and two donors with HBV DNA. All four donor samples expressed over 90% neutralization in the anti-HBc supplementary testing, indicating high titer anti-HBc. These findings seem to support the suggested policy of donor exclusion based on the anti-HBc and anti-HBsAg serology as a means to eliminate low grade carriers of HBV in endemic areas without jeopardizing the blood supply.
Development of Medical Technology for Contingency Response to Marrow Toxic Agents
2012-07-26
Confirmatory Testing DC Donor Center DIY Do it yourself DNA Deoxyribonucleic Acid DoD Department of Defense D/R Donor/Recipient EBMT European Group...recruitment support (Search screen redesign, New Donor Notes, HHQ enhancements, Site Maintenance redesign, Communications History, DIY ). National...Web and Do It Yourself ( DIY ) This project enables the ability to electronically contact the donors via email and allow them to update their contact
Osaro, Erhabor; Mohammed, Ndakotsu; Zama, Isaac; Yakubu, Abdulrahaman; Dorcas, Ikhuenbor; Festus, Aghedo; Kwaifa, Ibrahim; Sani, Ibrahim
2014-01-01
Introduction Blood transfusions remain a substantial source of HIV in SSA particularly among children and pregnant women. Aims and objectives: This aim of this retrospective study was to investigate the prevalence of p24 antigen among HIV antibody seronegative blood donors in Sokoto, North West Nigeria. Methods A total of 15,061 HIV antibody negative blood donors with mean age and age range (29.2 ± 8.18 and 18-50 years) were screened for p24 antigen between January 2010 to July 2013 using the Diapro Diagnostic immunoassay kit for P24 antigen (King Hawk Pharmaceuticals Beijing China). Results The overall prevalence of p24 antigen among the HIV antibody negative donors sample was 5.84%. The yearly prevalence was 9.79, 8.12, 2.7 and 2.84% respectively in 2010, 2011, 2012 and 2013. Of the total number of blood donor tested, 14,968 (99.38%) were males while 93 (0.62%) were females. The prevalence of P24 antigen was significantly higher among male blood donors 873 (5.8%) compared to females 7(0.05%), (p= 0.001). P24 positivity was significantly higher among blood group O blood donors compared to A, B and AB donors (494 (3.29%) compared to 184 (1.89%), 196 (1.30%) and 6 (0.04%)) respectively, p = 0.001). The prevalence of P24 antigen was significantly higher among Rhesus positive blood donors compared to Rhesus negative (807 (5.36%) versus 73 (0.48%), p =0.001). Conclusion Blood transfusion in Nigeria is associated with increased risk of HIV transmission. There is the urgent need to optimize the screening of blood donors in Nigeria by the inclusion of p24 antigen testing into the blood donor screening menu. The Nigerian government urgently need to adopt the WHO blood safety strategies to reduce the risk of transmission of HIV through blood transfusion. PMID:25419301
... allograft bone comes from donors who have died. Tissue banks screen these donors and disinfect and test the donated bone to make sure it is safe to use. If the transplanted bone comes ... an autograft. Autograft bone often comes from your ribs, hips or a leg.
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System
Tyagi, Surabhi; Tyagi, Alok
2013-01-01
Background: Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. Aim: To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. Material and Methods: All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti–HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme–linked immunosorbent assay (ELISA) technique using micro–elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. Statistical Analysis: The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Results: Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Conclusion: Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think…. PMID:24179900
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System.
Tyagi, Surabhi; Tyagi, Alok
2013-09-01
Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti-HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme-linked immunosorbent assay (ELISA) technique using micro-elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think….
Massey, Emma K; Timmerman, Lotte; Ismail, Sohal Y; Duerinckx, Nathalie; Lopes, Alice; Maple, Hannah; Mega, Inês; Papachristou, Christina; Dobbels, Fabienne
2018-01-01
Thorough psychosocial screening of donor candidates is required in order to minimize potential negative consequences and to strive for optimal safety within living donation programmes. We aimed to develop an evidence-based tool to standardize the psychosocial screening process. Key concepts of psychosocial screening were used to structure our tool: motivation and decision-making, personal resources, psychopathology, social resources, ethical and legal factors and information and risk processing. We (i) discussed how each item per concept could be measured, (ii) reviewed and rated available validated tools, (iii) where necessary developed new items, (iv) assessed content validity and (v) pilot-tested the new items. The resulting ELPAT living organ donor Psychosocial Assessment Tool (EPAT) consists of a selection of validated questionnaires (28 items in total), a semi-structured interview (43 questions) and a Red Flag Checklist. We outline optimal procedures and conditions for implementing this tool. The EPAT and user manual are available from the authors. Use of this tool will standardize the psychosocial screening procedure ensuring that no psychosocial issues are overlooked and ensure that comparable selection criteria are used and facilitate generation of comparable psychosocial data on living donor candidates. © 2017 Steunstichting ESOT.
Galel, Susan A; Simon, Toby L; Williamson, Phillip C; AuBuchon, James P; Waxman, Dan A; Erickson, Yasuko; Bertuzis, Rasa; Duncan, John R; Malhotra, Khushbeer; Vaks, Jeffrey; Huynh, Nancy; Pate, Lisa Lee
2018-03-01
Use of nucleic acid testing (NAT) in donor infectious disease screening improves transfusion safety. Advances in NAT technology include improvements in assay sensitivity and system automation, and real-time viral target discrimination in multiplex assays. This article describes the sensitivity and specificity of cobas MPX, a multiplex assay for detection of human immunodeficiency virus (HIV)-1 Group M, HIV-2 and HIV-1 Group O RNA, HCV RNA, and HBV DNA, for use on the cobas 6800/8800 Systems. The specificity of cobas MPX was evaluated in samples from donors of blood and source plasma in the United States. Analytic sensitivity was determined with reference standards. Infectious window periods (WPs) before NAT detectability were calculated for current donor screening assays. The specificity of cobas MPX was 99.946% (99.883%-99.980%) in 11,203 blood donor samples tested individually (IDT), 100% (99.994%-100%) in 63,012 donor samples tested in pools of 6, and 99.994% (99.988%-99.998%) in 108,306 source plasma donations tested in pools of 96. Seven HCV NAT-yield donations and one seronegative occult HBV infection were detected. Ninety-five percent and 50% detection limits in plasma (IU/mL) were 25.7 and 3.8 for HIV-1M, 7.0 and 1.3 for HCV, and 1.4 and 0.3 for HBV. The HBV WP was 1 to 4 days shorter than other donor screening assays by IDT. cobas MPX demonstrated high specificity in blood and source plasma donations tested individually and in pools. High sensitivity, in particular for HBV, shortens the WP and may enhance detection of occult HBV. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
Sarkodie, Francis; Owusu-Dabo, Ellis; Hassall, Oliver; Bates, Imelda; Bygbjerg, Ib C; Ullum, Henrik
2016-09-01
To describe the recalled medical history, clinical manifestations, and treatment of yaws and syphilis by syphilis seroreactive blood donors in Kumasi, Ghana. Of the blood donors at Komfo Anokye Teaching Hospital, Kumasi, Ghana tested with the syphilis rapid diagnostic test (RDT) and later by rapid plasma reagin (RPR) test, 526 were seroreactive. Four hundred and seventy-one (89.5%) of these subjects were confirmed with the Ortho-Vitros Syphilis TP test as the gold standard and were interviewed to determine past or present clinical manifestations of yaws and syphilis. Of the 471 respondent donors, 28 (5.9%) gave a history of skin lesions and sores; four (14.3%) of these subjects, who were all male and RPR-positive, recalled a diagnosis of syphilis. All four reported having had skin lesions/bumps with slow-healing sores, but only one of them had had these symptoms before the age of 15 years. A small proportion of confirmed seroreactive donors in this sample had any recall of symptoms or treatment for yaws or syphilis. These data suggest that clinical questioning adds little further information to the current screening algorithm. The relative contribution of yaws and syphilis to frequent positive tests in endemic areas remains speculative. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Retention of "safe" blood donors. The Retrovirus Epidemiology Donor Study.
Thomson, R A; Bethel, J; Lo, A Y; Ownby, H E; Nass, C C; Williams, A E
1998-04-01
There are obvious advantages to increasing donor retention. However, for reasons of blood safety, certain donors may, in fact, be more desirable to retain than others. "Safe" donors are defined as those who provided a blood donation that was negative on all laboratory screening tests and who subsequently reported no behavioral risks in response to an anonymous survey. This study identifies the most important factors affecting the intention of "safe" donors to provide another donation. An anonymous survey asking about donation history, sexual history, injecting drug use, and recent donation experience was mailed to 50,162 randomly selected allogeneic donors (including directed donors) who gave blood from April through July or from October through December 1993 at one of the five United States blood centers participating in the Retrovirus Epidemiology Donor Study. Before mailing, questionnaires were coded to designate donors with nonreactive laboratory screening tests at their most recent donation. A total of 34,726 donors (69%) responded, with substantially higher response among repeat donors. According to reported intentions only, the vast majority of "safe" donors indicated a high likelihood of donating again within the next 12 months. Only 3.4 percent reported a low likelihood of donating again. A comparison of those likely to return and those unlikely to return reveals significant differences in demographics and in ratings of the donation experience. A higher proportion of those unlikely to return were first-time donors, minority-group donors, and donors with less education. The highest projected loss among "safe" donors was seen for those who gave a fair to poor assessment of their treatment by blood center staff or of their physical well-being during or after donating. These data suggest that efforts to improve donors' perceptions of their donation experience, as well as attention to the physical effects of blood donation, may aid in the retention of both repeat and first-time donors.
Design and Evolution of the Asporto Heart Preservation Device.
Rivard, Andrew L
2015-06-01
The Asporto Heart Preservation Device is a system providing perfusion of cardioplegia to the donor heart using a computer-controlled peristaltic pump in a thermoelectrically cooled and insulated container. In 1998, a user interface was developed at the University of Minnesota consisting of a touch screen and battery-backed microcontroller. Power was supplied by a 120 VAC to 12 VDC converter. An upgrade to the insulated cooler and microcontroller occurred in 2002, which was followed by proof of concept experimental pre-clinical transplants and tests demonstrating the efficacy of the device with isolated donor hearts. During the period between 2002 and 2006, a variety of donor organ containers were developed, modified, and tested to provide an optimal sterile environment and fluid path. Parallel development paths encompass formalized design specifications for final prototypes of the touch screen/microcontroller, organ container, and thermoelectric cooler.
DAT positivity in blood donors: a perplexing scenario.
Bedi, Ravneet Kaur; Mittal, Kshitija; Sood, Tanvi; Kumar, Rakesh; Praveen, Ajay S
2014-04-01
A blood request was received for 70 year male patient suffering from Chronic Obstructive Pulmonary Disease with anemia. One unit was found incompatible in AHG phase. Patient's antibody screen, indirect antiglobulin test (IAT), direct antiglobulin test (DAT) and auto control was negative. DAT of donor unit was positive with anti IgG gel card and negative with C3d reagent along with positive auto control. Donor was 30 year male with no history of blood transfusion and medication and had no evidence of hemolysis. Donors with positive DAT should be deferred, notified and referred to physician but further studies are required. Copyright © 2014 Elsevier Ltd. All rights reserved.
Sehgal, Sahil; Shaiji, P.S
2017-01-01
Introduction Transfusion Transmissible Infections (TTIs) such as Human Immunodeficiency Virus (HIV), Hepatitis B virus (HBV), Hepatitis C Virus (HCV) and syphilis pose a threat to blood safety in a developing country like India. Aim To determine the prevalence of TTIs among healthy donors in Andaman and Nicobar Islands, India, and to further help in determination of the population subset to be focused on for enhancing blood donor pool. Materials and Methods This retrospective cross-sectional study was conducted on all voluntary and replacement donors in a tertiary health care centre in Andaman and Nicobar Islands for a period of three years. Donor blood was screened for HIV, HBV, HCV, Syphilis and malarial parasite using rapid kits and ELISA. Results Out of 12,118 donors, 97.01% were males and 2.99% were females. 9409 (77.64%) were voluntary donors and 2709 (22.35%) were replacement donors. Majority of the screened donors belonged to 25 to 40 age group. Out of 12,118 donors, 265 (2.18%) were seropositive. Among them, 8 (0.066%) were HIV positive, 15 (0.124%) HCV positive, 128 (1.056%) HBsAg positive, 30 (0.247%) Syphilis positive and 84 (0.693%) were positive for malarial antigen. Yearly prevalence of seropositivity was 2.370%, 2.113% and 2.082% for three consecutive years. Conclusion With high prevalence of TTIs among healthy donors, safe blood transfusion is still a challenge in developing countries. This continues to place unacceptable burden on health sector. There is a need for encouragement of voluntary blood donation, strict donor selection criteria and sensitive screening tests to minimize TTIs in Indian setting. PMID:28571144
Sehgal, Sahil; Shaiji, P S; Brar, Rupinder Kaur
2017-04-01
Transfusion Transmissible Infections (TTIs) such as Human Immunodeficiency Virus (HIV), Hepatitis B virus (HBV), Hepatitis C Virus (HCV) and syphilis pose a threat to blood safety in a developing country like India. To determine the prevalence of TTIs among healthy donors in Andaman and Nicobar Islands, India, and to further help in determination of the population subset to be focused on for enhancing blood donor pool. This retrospective cross-sectional study was conducted on all voluntary and replacement donors in a tertiary health care centre in Andaman and Nicobar Islands for a period of three years. Donor blood was screened for HIV, HBV, HCV, Syphilis and malarial parasite using rapid kits and ELISA. Out of 12,118 donors, 97.01% were males and 2.99% were females. 9409 (77.64%) were voluntary donors and 2709 (22.35%) were replacement donors. Majority of the screened donors belonged to 25 to 40 age group. Out of 12,118 donors, 265 (2.18%) were seropositive. Among them, 8 (0.066%) were HIV positive, 15 (0.124%) HCV positive, 128 (1.056%) HBsAg positive, 30 (0.247%) Syphilis positive and 84 (0.693%) were positive for malarial antigen. Yearly prevalence of seropositivity was 2.370%, 2.113% and 2.082% for three consecutive years. With high prevalence of TTIs among healthy donors, safe blood transfusion is still a challenge in developing countries. This continues to place unacceptable burden on health sector. There is a need for encouragement of voluntary blood donation, strict donor selection criteria and sensitive screening tests to minimize TTIs in Indian setting.
Karakoc, Ayse Esra; Berkem, Rukiye; Irmak, Hasan; Demiroz, Ali Pekcan; Yenicesu, Idil; Ertugrul, Nigar; Arslan, Önder; Kemahli, Sabri; Yilmaz, Sevinc; Ozcebe, Osman; Kara, Abdurrahman; Ozet, Gulsum; Acikgoz, Ziya Cibali; Acikgoz, Tulin
2017-10-01
In this study we aimed to propose an algorithm for initial anti HCV EIA reactive blood donations in Turkey where nucleic acid amplification tests are not yet obligatory for donor screening. A total of 416 anti HCV screening test reactive donor samples collected from 13 blood centers from three cities in Turkey were tested in duplicate by Ortho HCV Ab Version 3.0 and Radim HCV Ab. All the repeat reactive samples were tested by INNO-LIA HCV Ab 3.0 or Chiron RIBA HCV 3.0 and Abbott Real Time HCV. Intra-assay correlations were calculated with Pearson r test. ROC analysis was used to study the relationship between EIA tests and the confirmatory tests. The number of repeat reactive results with Ortho EIA were 221 (53.1%) whereas that of microEIA, 62 (14.9%). Confirmed positivity rate was 14.6% (33/226) by RIBA and 10.6% (24/226) by NAT. Reactive PCR results were predicted with 100% sensitivity and 95% specificity with S/CO levels of 8.1 with Ortho EIA and 3.4 with microEIA. Repeat reactivity rates declined with a second HCV antibody assay. Samples repeat reactive with one HCV antibody test and negative with the other were all NAT negative. All the NAT reactive samples were RIBA positive. None of the RIBA indeterminate or negative samples were NAT reactive. Considering the threshold values for EIA kits determined by ROC analysis NAT was decided to be performed for the samples above the threshold value and a validated supplemental HCV antibody test for the samples below. Copyright © 2017 Elsevier Ltd. All rights reserved.
Schink, Susanne B.; Offergeld, Ruth; Schmidt, Axel J.; Marcus, Ulrich
2018-01-01
Background The predominant mode of transmission of human immunodeficiency virus (HIV) in Europe is male-to-male transmission. Men who have sex with men (MSM) are deferred from donating blood in many countries, but nevertheless do donate blood. Based on data from 34 countries, we estimated the proportion of MSM screened for HIV in the context of a blood donation and identified individual factors associated with this HIV screening in order to propose possible public health interventions. Materials and methods In 2010, the first European MSM Internet Survey (EMIS) collected self-reported data on HIV testing from >180,000 MSM in 38 European countries. Using logistic regression, demographic and behavioural factors associated with screening for HIV in blood establishments were identified. Stratified by European sub-region, we analysed the proportion of MSM screening in blood establishments by time elapsed since last negative HIV test. Results Donor eligibility criteria for MSM vary across Europe with most countries using permanent deferral. The Western region had the lowest (2%) proportion of MSM screened in blood establishments and the Northeastern region had the highest (14%). Being <25 years old, not disclosing sexual attraction to men, never having had anal intercourse with a man, having a female partner, living in a rural area, and certain European sub-regions or countries of residence increased the likelihood of being screened in blood establishments. Discussion In spite of deferral policies, MSM are screened for HIV in the context of blood donations. Gay-friendly testing services are rare in rural areas, and young men might be reluctant to disclose their sexual orientation. Recent developments, such as home sampling, might offer new testing possibilities for those not reached by established services yet wishing to know their HIV status. Donor selection procedures should be improved. Both interventions might help to further reduce the risk of transfusion-transmitted infections. PMID:28488974
Smythe, Claire; White, Nicola; Winter, Joyleen; Cowie, Anne
2015-06-01
Femoral head donation at the time of hip replacement surgery provides a much needed resource of bone allograft to orthopaedic surgeons. Prior to 2005, potential femoral head donors were identified and consented in the hospital setting on the day of surgery. This resulted in over 40 % of donations failing post operatively suggesting that more effort could be given to pre-operative screening resulting in substantial savings in the cost associated with collection and testing of donors who were subsequently failed. The Donor Liaison role was implemented in 2005 to coordinate a Femoral Head Donation program maximising the number of successful donations through pre-operative screening. This study reviews the effectiveness of pre-operative screening of potential femoral head donors at PlusLife from 2002-2012. A retrospective audit of the database was undertaken 2002-2012 and medical/social reasons for pre-operative and postoperative failures were collated into 4 main categories to enable comparison: malignancy, autoimmune conditions, variant Creutzfeldt Jakob disease risk and general medical/social reasons. The number of femoral heads failed post operatively has decreased significantly from 26 % in 2003 to 6 % in 2012. A cost of $121,000 was expended on femoral heads failed post operatively in 2004, as compared to $20,350 in 2012. Donors excluded due to the 4 main categories (medical/social history) were identified pre-operatively in over 80 % of all cases. Preoperative screening of femoral head donors through a coordinated Femoral Head Donation Program is a safe and cost effective method.
Diagnostic accuracy of blood centers in the screening of blood donors for viral markers
Dogbe, Elliot Eli; Arthur, Fareed
2015-01-01
Introduction Blood transfusion still remains a life saving intervention in almost all healthcare facilities worldwide. Screening of blood donors/blood units is done in almost every blood bank facility before the blood units/blood components are transfused to prevent transfusion-transmissible infections. The kind of testing kits or the methods used by a facility and the technical expertise of the personnel greatly affects the screening results of a facility. This study was aimed at evaluating the diagnostic accuracy of five hospital-based blood bank testing facilities (Komfo Anokye Teaching Hospital KNUST, Kwame Nkrumah University of Science and Technology, Agogo, Bekwai and Sunyani) that used rapid immunochromatograhic assays (RIA) in screening blood donors/blood units in Ghana. Methods Blood samples (300) from the five testing facilities and their screening results for hepatitis B surface antigen (HBsAg), antibodies to hepatitis C virus (HCV) and human immunodeficiency virus (HIV) using RIAs were obtained. All the samples were then analysed for the three viral markers using 3rd generational enzyme linked immunosorbent assay (ELISA) kit as the gold standard. Results The mean false positive for HBsAg was 2.2% with Bekwai testing facility having the highest of 4.4%. For HCV, the mean false positive was 2.8% with Agogo and Bekwai testing facilities having the highest of 8.7% respectively. For HIV screening, the mean false positive was 11.1% with Bekwai testing facility having the highest of 28.0%. The mean false negative for the facilities were 3.0% for HBV, 75.0% for HCV and 0.0% for HIV with KATH having the highest of 6.3% for HBV, Bekwai having the highest of 100% for HCV and no facility showing false negative for HIV. Mean sensitivity of the screening procedure for the facilities was 97.0%, 25.0% and 100.0% whilst the mean specificity was 97.8%, 97.2% and 88.9% for HBV, HCV and HIV respectively. Statistical comparison among the testing facilities showed no significant differences among the various testing centres for HBV screening; however, significant differences were obtained for HCV and HIV screening. Conclusion This study has shown that there is no standardised screening procedure for blood bank testing facilities in the country. There is therefore an urgent need for an internal and external control body to oversee screening procedures in blood banks across the country. PMID:26090067
Vogler, Ingridt Hildegard; Saito, Mariza; Spinosa, Adriana Aparecida; da Silva, Marilza Celina; Munhoz, Egberto; Reiche, Edna Maria Vissoci
2011-01-01
Background For transfusion purposes, blood donors must be accepted both in clinical and serological evaluations and must not have excluded their own donation using the confidential unit exclusion. Aim The objective of this study was to verify whether blood donors who choose self exclusion are more likely to be positive in serological tests than donors who do not. Methods A cross-sectional analysis was carried out of 51,861 consecutive whole blood donations from January 2004 to December 2008 at a public blood bank in Londrina, Southern Brazil. Results Self exclusion was chosen in 1672 (3.2%) donations, most frequently by first-time blood donors (p-value < 0.0001), by blood donors from external collections (p-value < 0.0001), by men (p value < 0.0001) and by under 30-year-old donors (p-value < 0.0001). The frequency of positive serology was 5.3% in the group that chose self exclusion and 3.5% in the group that did not choose self exclusion (p-value < 0.0001). Conclusions These results show that confidential unit exclusion used in this blood bank is effective and is inexpensive. However, the diagnostic power to detect blood-borne infections was low and resulted in the discard of a high number of blood bags without any direct or indirect serologic markers of pathogens. The use of confidential unit exclusion could be replaced with molecular tests to screen blood donors. PMID:23049338
Improvement of a rapid screening test for chronic granulomatous disease.
Iacobini, M; Duse, M; Di Coste, A; Balducci, L
2013-01-01
Diagnosis of CGD is made by demonstrating absent or markedly reduced oxidase activity in stimulated neutrophils. The screening test proposed is based upon the naked eye evaluation of the reduction of NBT on a solid surface. It seems to be a useful tool for rapid and inexpensive detection of CGD patients, especially for large-scale screening purposes. The test was carried out on forty-five subjects: two males affected by CGD, three female carriers and forty healthy donors. The test confirmed the results obtained with flow cytometric and NBT assays.
Probability of viremia with HBV, HCV, HIV, and HTLV among tissue donors in the United States.
Zou, Shimian; Dodd, Roger Y; Stramer, Susan L; Strong, D Michael
2004-08-19
Tissue-banking organizations in the United States have introduced various review and testing procedures to reduce the risk of the transmission of viral infections from tissue grafts. We estimated the current probability of undetected viremia with hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus (HIV), and human T-lymphotropic virus (HTLV) among tissue donors. Rates of prevalence of hepatitis B surface antigen (HBsAg) and antibodies against HIV (anti-HIV), HCV (anti-HCV), and HTLV (anti-HTLV) were determined among 11,391 donors to five tissue banks in the United States. The data were compared with those of first-time blood donors in order to generate estimated incidence rates among tissue donors. The probability of viremia undetected by screening at the time of tissue donation was estimated on the basis of the incidence estimates and the window periods for these infections. The prevalence of confirmed positive tests among tissue donors was 0.093 percent for anti-HIV, 0.229 percent for HBsAg, 1.091 percent for anti-HCV, and 0.068 percent for anti-HTLV. The incidence rates were estimated to be 30.118, 18.325, 12.380, and 5.586 per 100,000 person-years, respectively. The estimated probability of viremia at the time of donation was 1 in 55,000, 1 in 34,000, 1 in 42,000, and 1 in 128,000, respectively. The prevalence rates of HBV, HCV, HIV, and HTLV infections are lower among tissue donors than in the general population. However, the estimated probability of undetected viremia at the time of tissue donation is higher among tissue donors than among first-time blood donors. The addition of nucleic acid-amplification testing to the screening of tissue donors should reduce the risk of these infections among recipients of donated tissues. Copyright 2004 Massachusetts Medical Society
Shafer, Teresa J; Schkade, David; Schkade, Lawrence; Geier, Steven S; Orlowski, Jeffrey P; Klintmalm, Goran
2011-09-01
Patients' deaths due to the organ donor shortage make it imperative that every suitable organ be transplanted. False-positive results of tests for infection with the human immunodeficiency virus (HIV) result in lost organs. A survey of US organ procurement organizations collected the numbers of donors and ruled-out potential donors who had a positive result on an HIV test from January 1,2006, to October 31, 2008. Sixty-two percent of US organ procurement organizations participated. Of the 12397 donor/nondonor cases, 56 (0.45%) had an initial positive result on an HIV antibody or HIV nucleic acid test, and only 8 (14.3%) of those were confirmed positive. Of the false-positive results, 50% were from HIV antibody tests and 50% were from HIV nucleic acid tests. Organs are a scarce, finite, and perishable resource. Use of HIV antibody testing has produced a remarkably safe track record of avoiding HIV transmission, with 22 years of nonoccurrence between transmissions. Because false positives occur with any test, including the HIV Ab test, adding nucleic acid testing to the standard donor testing panel doubles the number of false-positive HIV test results and thus the number of medically suitable donors lost. The required HIV antibody test is 99.99% effective in preventing transmission of the HIV virus. Adding the HIV nucleic acid test to routine organ donor screening could result in as many as 761 to 1551 unnecessary deaths of patients between HIV transmission events because medically suitable organs are wasted.
Challenges in fecal donor selection and screening for fecal microbiota transplantation: A review.
Woodworth, Michael H; Carpentieri, Cynthia; Sitchenko, Kaitlin L; Kraft, Colleen S
2017-05-04
Fecal microbiota transplantation is best understood as an effective and inexpensive therapy for recurrent Clostridium difficile infection but fecal donor selection and screening should be periodically revised. Here, we review current recommendations for selection and screening of fecal donors for fecal microbiota transplantation. We recommend considering diabetes mellitus, prior cardiovascular events, and clinical healthcare exposure as fecal donor exclusion criteria until more is known about the association of these conditions with the human gut microbiome. We review the non-bacterial members of the human gut microbiome, associations of the gut microbiome with colorectal malignancies, the human gut resistome and how these may impact future donor screening recommendations. Collaboration between clinicians, clinical laboratory scientists, industry and regulatory agencies will be critically important for continued improvement in donor selection and screening.
1994-05-20
Although previous recommendations for preventing transmission of human immunodeficiency virus (HIV) through transplantation of human tissue and organs have markedly reduced the risk for this type of transmission, a case of HIV transmission from a screened, antibody-negative donor to several recipients raised questions about the need for additional federal oversight of transplantation of organs and tissues. A working group formed by the Public Health Service (PHS) in 1991 to address these issues concluded that further recommendations should be made to reduce the already low risk of HIV transmission by transplantation of organs and tissues. In revising these recommendations, the PHS sought assistance from public and private health professionals and representatives of transplant, public health, and other organizations. The revised guidelines address issues such as donor screening, testing, and exclusionary criteria; quarantine of tissue from living donors; inactivation or elimination of infectious organisms in organs and tissues before transplantation; timely detection, reporting, and tracking of potentially infected tissues, organs, and recipients; and recall of stored tissues from donors found after donation to have been infected. Factors considered in the development of these guidelines include differences between the screening of living and cadaveric donors; time constraints due to organ/tissue viability that may preclude performing certain screening procedures; differences in the risk of HIV transmission from various organs and tissues; differences between systems for procuring and distributing organs and tissues; the effect of screening practices on the limited availability of organs and some tissues; and the benefit of the transplant to the recipient.
Effective serological and molecular screening of deceased tissue donors.
Kitchen, A D; Newham, J A; Gillan, H L
2013-12-01
A comprehensive and effective screening programme is essential to support the banking of tissues from deceased donors. However, the overall quality of the samples obtained from deceased donors, quantity and condition, is often not ideal, and this may lead to problems in achieving accurate and reliable results. Additionally a significant percentage of referrals are still rejected upon receipt as unsuitable for screening. We are actively involved in improving the overall quality of deceased donor screening outcomes, and have specifically evaluated and validated both serological and molecular assays for this purpose, as well as developing a specific screening strategy to minimise the specificity issues associated with serological screening. Here we review the nature and effectiveness of the deceased donor screening programme implemented by National Health Service Blood and Transplant (NHSBT), the organisation with overall responsibility for the supply of tissue products within England. Deceased donor screening data, serological and molecular, from August 2007 until May 2012 have been collated and analysed. Of 10,225 samples referred for serology screening, 5.5 % were reported as reactive; of 2,862 samples referred for molecular screening, 0.1 % were reported as reactive/inhibitory. Overall 20 % of the serological and 100 % of the molecular screen reactivity was confirmed as reflecting true infection. The use of a sequential serology screening algorithm has resulted in a marked reduction of tissues lost unnecessarily due to non-specific screen reactivity. The approach taken by NHSBT has resulted in the development of an effective and specific approach to the screening of deceased tissue donors.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
... the FDA regulations designed to ensure the continued safety, purity, and potency of the product. In... components found to be reactive by a screening test for evidence of certain communicable disease agent(s) or collected from a donor with a record of a reactive screening test. Furthermore, Sec. Sec. 610.40(h)(2)(ii)(C...
Chandrashekar, Shivaram
2014-01-01
Background and Objectives: It is well established that Nucleic acid testing (NAT) reduces window phase of transfusion transmissible infections (TTI) and helps improve blood safety. NAT testing can be done individually or in pools. The objectives of this study were to determine the utility, feasibility and cost effectiveness of an in-house minipool-NAT(MP-NAT). Materials and Methods: Blood donors were screened by history, tested by ELISA and sero-negative samples were subjected to an in-house NAT by using reverse transcriptase-polymerase chain reaction (RT-PCR). Testing was done in mini-pools of size eight (8). Positive pools were repeated with individual samples. Results: During the study period of Oct 2005-Sept 2010 (5 years) all blood donors (n=53729) were screened by ELISA. Of which 469 (0.87%) were positive for HIV-1, HBV or HCV. Sero-negative samples (n=53260) were screened by in-house MP-NAT. HIV-NAT yield was 1/53260 (n=1) and HBV NAT yield (n=2) was 1/26630. Conclusion: NAT yield was lower than other India studies possibly due to the lower sero-reactivity amongst our donors. Nevertheless it intercepted 9 lives including the components prepared. The in-house assay met our objective of improving blood safety at nominal cost and showed that it is feasible to set up small molecular biology units in medium-large sized blood banks and deliver blood within 24-48 hours. The utility of NAT (NAT yield) will vary based on the donor population, the type of serological test used, the nature of kit employed and the sensitivity of NAT test used. The limitations of our in-house MP-NAT consisted of stringent sample preparation requirements, with labor and time involved. The benefits of our MP-NAT were that it acted as a second level of check for ELISA tests, was relatively inexpensive compared to ID-NAT and did not need sophisticated equipment. PMID:24678172
Noninvasive methods for haemoglobin screening in prospective blood donors.
Belardinelli, A; Benni, M; Tazzari, P L; Pagliaro, P
2013-08-01
The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening. Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (n = 445 donors) and by the Pronto-7 (Masimo) test (n = 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter). Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0.29 g/dl, the standard deviation of the differences (SDD) of 0.98 and 95% limits of agreement from -1.64 to 2.21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of -0.53 g/dl, SDD of 1.04 and 95% limits of agreement from -2.57 to 1.51. Cumulative analysis of all 908 donors, as tested by the usual fingerstick test showed a bias of 0.83 g/dl, SDD of 0.70 and 95% limits of agreement from -0.54 to 2.20 compared with the Coulter Cell Counter. Compared with the Coulter Counter, the specificity of the methods was 99.5% for fingerstick, 97% for OrSense and 83% for Massimo, and the sensitivity was 99, 98 and 93%, respectively. Analysis of finger pulp blood by either direct sampling by fingerstick and Hemocue, or by noninvasive haemoglobin tests does not replicate the results of cell counter analysis of venous samples. Compared with fingerstick, noninvasive haemoglobin tests eliminate pain and reduce stress, but have a lower level of specificity and sensitivity. © 2013 International Society of Blood Transfusion.
Selection strategies for newly registered blood donors in European countries
Lieshout-Krikke, Ryanne W.; Domanovic, Dragoslav; de Kort, Wim; Mayr, Wolfgang; Liumbruno, Giancarlo M.; Pupella, Simonetta; Kurz, Johann; Knutson, Folke; MacLennan, Sheila; Folléa, Gilles
2017-01-01
Background Two selection strategies for newly-registered blood donors are available: a single-visit selection called the standard selection procedure (SSP), and a two-stage selection named predonation and donation screening (PDS). This study reviews the selection strategies for newly-registered donors currently applied in European countries. Material and methods We collected data on donor selection procedures, blood donation, laboratory screening and HIV, HCV and HBV positive donors/donations from 2010 to 2013 in 30 European countries by using questionnaires. We grouped the countries according to the applied selection strategy, and for each country, we calculated the 4-year prevalence of confirmed positive results indicating the presence of overall and recent HIV, HCV and HBV infections among first-time and repeat donations and among newly-registered donors. Results Most of the 24 countries (80%) apply the SSP strategy for selection of newly-registered donors. Twenty-two countries (73.3%) employ a nucleic acid amplification testing in addition to the mandatory serological screening. The survey confirms a higher overall prevalence of HIV, HCV and HBV infections among first-time donations and newly-registered donors than among repeat donations. In contrast, the prevalence of recently acquired HIV and HCV infections was lower among first-time donations and newly-registered donors than among repeat donations, but higher for recent HBV infections (6.7/105 vs 2.6/105 in the SSP setting and 4.3/105 vs 0.5/105 in one country using PDS). The relatively low numbers of infected donors selected by PDS impeded accurate assessment of the prevalence of recent infections in first-time donations. Discussion The data from European countries provide inconclusive evidence that applying PDS reduces the risk of donations being made in the diagnostic window of first-time donors. The impact of PDS on the risk of window-period donations and blood donor management needs further investigation. PMID:27723449
Transfusion-transmitted malaria in Ghana.
Owusu-Ofori, Alex K; Betson, Martha; Parry, Christopher M; Stothard, J Russell; Bates, Imelda
2013-06-01
In sub-Saharan Africa, the prevalence of malaria parasitemia in blood donors varies from 0.6% to 50%. Although the burden of TTM in malaria-endemic countries is unknown, it is recommended that all donated blood is screened for malaria parasites. This study aimed to establish the incidence of TTM and identify a suitable screening test. Pregnant women, children, and immunocompromised malaria-negative transfusion recipients in a teaching hospital in Ghana were recruited over the course of 1 year. Parasites detected in recipients within 14 days of the transfusion were genotyped and compared to parasites in the transfused blood. The presence of genotypically identical parasites in the recipient and the transfused blood confirmed transfusion-transmitted malaria. Four malaria screening tests were compared to assess their usefulness in the context of African blood banks. Of the 50 patients who received transfusions that were positive for Plasmodium falciparum by polymerase chain reaction (PCR), 7 recipients developed PCR-detectable parasitemia. In only 1 of the 50 recipients (2%) was the parasite identical to that in the transfused blood. The prevalence of P. falciparum malaria in transfused blood was 4.7% (21/445) by microscopy, 13.7% (60/440) by rapid diagnostic test, 18% (78/436) by PCR, and 22.2% (98/442) by enzyme immunoassay. Although malaria parasites are commonly detected in blood donors in malaria-endemic areas, transfusion-transmitted malaria occurs infrequently. Policies recommend screening blood donors for malaria, but none of the commonly used methods is sufficiently sensitive to be used by blood banks in malaria-endemic countries.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-15
... Blood and Blood Components, Including Source Plasma, To Reduce the Risk of Transmission of Hepatitis B... Components, including Source Plasma, to Reduce the Risk of Transmission of Hepatitis B Virus,'' dated October... (NAT) to screen blood donors for hepatitis B virus (HBV) deoxyribonucleic acid (DNA) and...
Matsumoto, Chieko; Sagara, Yasuko; Sobata, Rieko; Inoue, Yukiko; Morita, Maiko; Uchida, Shigeharu; Kiyokawa, Hiroyuki; Satake, Masahiro; Tadokoro, Kenji
2017-08-01
Adult T-cell leukemia/lymphoma (ATL) occurs in approximately 5% of individuals infected with human T-cell leukemia virus type 1 (HTLV-1). A high proviral load (PVL; more than four copies per 100 peripheral blood mononuclear cells (PBMCs) or 1.6 copies per 100 blood leukocytes) and being male are risk factors for ATL development. Whether anti-HTLV-1 antibody level is related to such risk is unknown. Here, PVL and antibody levels were examined using real-time PCR and other tests in 600 HTLV-1 positive screened Japanese blood donors to understand the relationship between PVL and antibody level in asymptomatic carriers and to gain insights toward better antibody testing for HTLV-1 infection. The 430 donors in whom proviral DNA was detected were considered as true positives for HTLV-1 infection. Among donors aged 40 years or older, more males than females had a PVL corresponding to more than 1.6% infected leukocytes, and an antibody titer below the median (P = 0.0018). In antibody tests using an HTLV-1 positive cell line or Env antigens there was a large discrepancy in antibody titer among 13 provirus-positive samples, probably suggesting that antibody-based screening tests should incorporate multiple HTLV-1 antigens, such as Gag and Env antigens. © 2017 Wiley Periodicals, Inc.
Molecular fragil X screening in normal populations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spence, W.C.; Black, S.H.; Fallon, L.
In December, 1993, we initiated a pilot project in which DNA fragile X (fraX) testing was offered during routine prenatal or genetic counseling to all pregnant women seen at the Genetics & IVF Institute, most of whom were referred for the indication of advanced maternal age. A brochure on fragile X syndrome was sent to each patient prior to her appointment and was reviewed by a counselor or physician during the counseling session. As of June 1995, 3,345 patients were offered testing; 474 women with no identified family history of mental retardation or learning disability and 214 women with amore » positive family history accepted the test on a self-pay basis. The second population screened was 271 potential donors in our anonymous egg donor program. DNA from blood was tested by Southern blot using EcoRI/EagI and StB12.3. If an expansion was detected, CGG repeat number was determined by PCR-based analysis. Among the 474 patients with unremarkable family histories, three fraX carriers were identified (repeat sizes = 60+), whereas none were found in the 214 patients with a positive family history. Among the potential egg donors, two high borderline patients were identified (repeat sizes = between 50 and 59). Our ongoing study indicates that screening of pregnant or preconceptual populations for fraX carrier status using DNA testing is accepted by many patients and is an important addition to current medical practice. 12 refs., 1 tab.« less
Eller, Leigh A; Eller, Michael A; Ouma, Benson J; Kataaha, Peter; Bagaya, Bernard S; Olemukan, Robert L; Erima, Simon; Kawala, Lilian; de Souza, Mark S; Kibuuka, Hannah; Wabwire-Mangen, Fred; Peel, Sheila A; O'Connell, Robert J; Robb, Merlin L; Michael, Nelson L
2007-10-01
The use of rapid tests for human immunodeficiency virus (HIV) has become standard in HIV testing algorithms employed in resource-limited settings. We report an extensive HIV rapid test validation study conducted among Ugandan blood bank donors at low risk for HIV infection. The operational characteristics of four readily available commercial HIV rapid test kits were first determined with 940 donor samples and were used to select a serial testing algorithm. Uni-Gold Recombigen HIV was used as the screening test, followed by HIV-1/2 STAT-PAK for reactive samples. OraQuick HIV-1 testing was performed if the first two test results were discordant. This algorithm was then tested with 5,252 blood donor samples, and the results were compared to those of enzyme immunoassays (EIAs) and Western blotting. The unadjusted algorithm sensitivity and specificity were 98.6 and 99.9%, respectively. The adjusted sensitivity and specificity were 100 and 99.96%, respectively. This HIV testing algorithm is a suitable alternative to EIAs and Western blotting for Ugandan blood donors.
Johnson, Stephanie T; Van Tassell, Eric R; Tonnetti, Laura; Cable, Ritchard G; Berardi, Victor P; Leiby, David A
2013-11-01
Babesia microti, an intraerythrocytic parasite, has been implicated in transfusion transmission. B. microti seroprevalence in Connecticut (CT) blood donors is approximately 1%; however, it is not known what percentage of donors is parasitemic and poses a risk for transmitting infection. Therefore, we determined the prevalence of demonstrable B. microti DNA in donors from a highly endemic area of CT and compared observed rates with concurrent immunofluorescence assay (IFA) testing results. Blood samples from consenting donors in southeastern CT were collected from mid-August through early October 2009 and tested by IFA for immunoglobulin G antibodies and real-time polymerase chain reaction (PCR) for B. microti DNA. IFA specificity was determined using blood donor samples collected in northwestern Vermont (VT), an area nonendemic for Babesia. Of 1002 CT donors, 25 (2.5%) were IFA positive and three (0.3%) were real-time PCR positive. Among the three real-time PCR-positive donors, two were also IFA positive, while one was IFA negative and may represent a window period infection. The two IFA- and real-time PCR-positive donors appeared to subsequently clear infection. The other real-time PCR-positive donor did not provide follow-up samples. Of 1015 VT donors tested by IFA, only one (0.1%) was positive, but may have acquired infection during travel to an endemic area. We prospectively identified several real-time PCR-positive blood donors, including an IFA-negative real-time PCR-positive donor, in an area highly endemic for B. microti. These results suggest the need to include nucleic acid testing in planned mitigation strategies for B. microti. © 2013 American Association of Blood Banks.
Code of Federal Regulations, 2010 CFR
2010-04-01
... CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND... donor screening or testing under §§ 1271.75, 1271.80 and 1271.85 for: (1) Cells and tissues for autologous use; or (2) Reproductive cells or tissue donated by a sexually intimate partner of the recipient...
Code of Federal Regulations, 2014 CFR
2014-04-01
... CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND... donor screening or testing under §§ 1271.75, 1271.80 and 1271.85 for: (1) Cells and tissues for autologous use; or (2) Reproductive cells or tissue donated by a sexually intimate partner of the recipient...
Martelli, C M; de Andrade, A L; das Dores, D; Cardoso, P; Almeida e Silva, S; Zicker, F
1991-02-01
Between October 1988 and February 1989, 1,033 voluntary first-time blood donors were screened for hepatitis B infection in five blood banks in Goiâna, Central Brazil. The survey was part of a major study designed to estimate seroprevalence of HBsAg and anti-HBs and to discuss methodological issues related to prevalence estimation based on data from blood banks. Donors were interviewed and blood samples were collected and tested for HBsAg and anti-HBs by ELISA tests. Prevalences of 1.9% and 10.9% were obtained for HBsAg and anti-HBs, respectively, and no statistical difference was found between the sexes. Prevalence of anti-HBs increased with age (X2 for trend = 7.9 p = 0.004). The positive predictive value and sensitivity of history of jaundice or hepatitis reported in the interview in detecting seropositives were 13.6% and 2.2%, respectively. The methodological issues, including internal and external validity of HBV prevalence estimated among blood donors are discussed. The potential usefulness of blood banks as a source of morbidity information for surveillance for Hepatitis B virus infection is stressed.
Wiberg, A; Granstam, A; Ingvast, S; Härkönen, T; Knip, M; Korsgren, O; Skog, O
2015-01-01
In this study we aim to describe the characteristics of non-diabetic organ donors with circulating diabetes-associated autoantibodies collected within the Nordic Network for Islet Transplantation. One thousand and thirty organ donors have been screened in Uppsala for antibodies against glutamic acid decarboxylase (GADA) and islet antigen-2 (IA-2A). The 32 non-diabetic donors that tested positive for GADA (3·3% of all non-diabetic donors) were studied in more detail, together with 32 matched controls. Mean age among the autoantibody-positive donors was 52·6 (range 21–74), family history of type 1 diabetes (T1D) was unknown, and no donor was genetically predisposed for T1D regarding the human leucocyte antigen (HLA) locus. Subjects were analysed for islet cell antibodies (ICA), insulin autoantibodies (IAA) and zinc transporter 8 antibodies (ZnT8A), and pancreas morphology and clinical data were examined. Eight non-diabetic donors tested positive for two antibodies and one donor tested positive for four antibodies. No insulitis or other signs of a diabetic process were found in any of the donors. While inflammatory cells were present in all donors, subjects with high GADA titres had significantly higher CD45 cell numbers in exocrine tissue than controls. The extent of fibrosis was more pronounced in autoantibody-positive donors, even in subjects with lower GADA titres. Notably, it is possible that events not related directly to T1D (e.g. subclinical pancreatitis) may induce autoantibodies in some cases. PMID:26313035
Ziemann, Malte; Heuft, Hans-Gert; Frank, Kerstin; Kraas, Sabine; Görg, Siegfried; Hennig, Holger
2013-05-01
Donors with short interdonation intervals (e.g., apheresis donors) have an increased risk of window period donations. The frequency of cytomegalovirus (CMV) window period donations is important information to decide whether selection of seronegative donors might be advantageous for patients at risk for transfusion-transmitted CMV infections (TT-CMV). CMV seroconversion in 93 donors with positive results in routine CMV antibody testing within at most 35 days after the last seronegative sample was evaluated by Western blot and/or a second antibody test. In donors with unconfirmed seroconversion, an additional later sample was tested. Concentration of CMV DNA was determined in pre- and postseroconversion samples. CMV seroconversion was confirmed in 12 donors (13%). Among these, the last seronegative sample was CMV DNA positive in three donors (25%, below 30 IU/mL). The first seropositive sample was CMV DNA positive in 10 donors (83%, maximum 1600 IU/mL). Both prevalence and median concentration of CMV DNA were higher in the first seropositive sample (p = 0.004 and p = 0.02), with maximum concentrations being reached about 2 weeks after seroconversion. No CMV DNA was detected in samples from donors with unconfirmed seroconversion. At least in donors with short interdonation intervals, most suspected CMV seroconversions are due to false-positive results of the screening test. As window period donations are rare and contain less CMV DNA than the first seropositive donation, avoidance of blood products from primarily seropositive donors is especially helpful to avoid TT-CMV if donors with short interdonation intervals are concerned. © 2013 American Association of Blood Banks.
Bone allograft banking in South Australia.
Campbell, D G; Oakeshott, R D
1995-12-01
The South Australian Bone Bank had expanded to meet an increased demand for allograft bone. During a 5 year period from 1988 to 1992, 2361 allografts were harvested from 2146 living donors and 30 cadaveric donors. The allografts were screened by contemporary banking techniques which include a social history, donor serum tests for HIV-1, HIV-2, hepatitis B and C, syphilis serology, graft microbiology and histology. Grafts were irradiated with 25 kGy. The majority of grafts were used for arthroplasty or spinal surgery and 99 were used for tumour reconstruction. Of the donated grafts 336 were rejected by the bank. One donor was HIV-positive and two had false positive screens. There were seven donors with positive serology for hepatitis B, eight for hepatitis C and nine for syphilis. Twenty-seven grafts had positive cultures. Bone transplantation is the most frequent non-haematogenous allograft in South Australia and probably nationally. The low incidence of infectious viral disease in the donor population combined with an aggressive discard policy has ensured relative safety of the grafts. The frequency of graft rejection was similar to other bone banks but the incidence of HIV was lower.
Saini, Purti Agrawal; Chakrabarti, Preeti Rihal; Varma, Amit V; Gambhir, Shankhini; Tignath, Gargi; Gupta, Priyanka
2017-01-01
The ultimate goal of a blood transfusion service is the provision of safe and adequate supply free from transfusion-transmitted infections (TTIs). TTIs not only threaten the recipient's safety, but they also increase disease burden. Seroprevalence of TTIs in healthy blood donors indirectly reflects the prevalence of these infections in the general healthy population. To study the seroprevalence of human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV) in healthy donors at a tertiary care hospital-based blood bank. To know the yearly and age-group prevalence of these TTIs as compared with other studies across India. This is 5 years observational cross-section study conducted in a tertiary hospital-based teaching institute of Central India (Malwa region). The results of serological testing of TTIs and donor variables were analyzed during 2011-2015. Chi-square test and Chi-square for trend analysis on TTIs prevalence. A total of 58,998 donors were screened for TTIs with dominance of male donation (99.7%). The overall cumulative seroprevalence was 1.14% in our study. The seroprevalence of HIV, HBV, and HCV was 0.09%, 0.98%, and 0.07%, respectively. We found a statistically significant increasing trend for HCV seropositivity during the study. Our study reflects an increasing trend of HCV seroprevalence over time. Thus, efforts are needed to increase the awareness and to educate the population in reducing risk factors for HCV infection.
Human milk sharing practices in the U.S.
Palmquist, Aunchalee E L; Doehler, Kirsten
2016-04-01
The primary objective of this study is to describe human milk sharing practices in the U.S. Specifically, we examine milk sharing social networks, donor compensation, the prevalence of anonymous milk sharing interactions, recipients' concerns about specific milk sharing risks, and lay screening behaviors. Data on human milk sharing practices were collected via an online survey September 2013-March 2014. Chi-square analyses were used to test the association between risk perception and screening practices. A total of 867 (661 donors, 206 recipients) respondents were included in the analyses. Most (96.1%) reported sharing milk face-to-face. Only 10% of respondents reported giving or receiving milk through a non-profit human milk bank, respectively. There were no reports of anonymous purchases of human milk. A small proportion of recipients (4.0%) reported that their infant had a serious medical condition. Screening of prospective donors was common (90.7%) but varied with social relationship and familiarity. Likewise, concern about specific milk sharing risks was varied, and risk perception was significantly associated (P-values = 0.01 or less) with donor screening for all risk variables except diet. Understanding lay perceptions of milk sharing risk and risk reduction strategies that parents are using is an essential first step in developing public health interventions and clinical practices that promote infant safety. © 2015 The Authors. Maternal & Child Nutrition published by John Wiley & Sons Ltd.
Drosten, C.; Seifried, E.; Roth, W. K.
2001-01-01
Screening of blood donors for human immunodeficiency virus type 1 (HIV-1) infection by PCR permits the earlier diagnosis of HIV-1 infection compared with that by serologic assays. We have established a high-throughput reverse transcription (RT)-PCR assay based on 5′-nuclease PCR. By in-tube detection of HIV-1 RNA with a fluorogenic probe, the 5′-nuclease PCR technology (TaqMan PCR) eliminates the risk of carryover contamination, a major problem in PCR testing. We outline the development and evaluation of the PCR assay from a technical point of view. A one-step RT-PCR that targets the gag genes of all known HIV-1 group M isolates was developed. An internal control RNA detectable with a heterologous 5′-nuclease probe was derived from the viral target cDNA and was packaged into MS2 coliphages (Armored RNA). Because the RNA was protected against digestion with RNase, it could be spiked into patient plasma to control the complete sample preparation and amplification process. The assay detected 831 HIV-1 type B genome equivalents per ml of native plasma (95% confidence interval [CI], 759 to 936 HIV-1 B genome equivalents per ml) with a ≥95% probability of a positive result, as determined by probit regression analysis. A detection limit of 1,195 genome equivalents per ml of (individual) donor plasma (95% CI, 1,014 to 1,470 genome equivalents per ml of plasma pooled from individuals) was achieved when 96 samples were pooled and enriched by centrifugation. Up to 4,000 plasma samples per PCR run were tested in a 3-month trial period. Although data from the present pilot feasibility study will have to be complemented by a large clinical validation study, the assay is a promising approach to the high-throughput screening of blood donors and is the first noncommercial test for high-throughput screening for HIV-1. PMID:11724836
42 CFR 493.1278 - Standard: Histocompatibility.
Code of Federal Regulations, 2013 CFR
2013-10-01
... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...
42 CFR 493.1278 - Standard: Histocompatibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...
Yilmaz, Soner; Unlu, Aytekin; Cetinkaya, Riza Aytac; Yapar, Mehmet; Avci, Ismail Yasar; Yilmaz, Sebahattin; Eyigun, Can Polat
2016-04-01
Screening of blood donations for antibodies against hepatitis B core antigen (anti-HBc) is used to prevent transfusion transmitted hepatitis B virus (HBV) infection. In this study, we studied the magnitude of blood donor gain by using a re-entry mechanism in our Blood Bank of Gulhane Military Academy of Medicine. Between January and May 2013, 5148 voluntary blood donors were screened by ELISA method for HBsAg, anti-HBc total and other screening markers, prospectively. Samples with repeated reactivity for the presence of anti-HBc were further tested with four supplemental assays. We detected 515 (10%) anti-HBc positive and 4612 (90%) anti-HBc negative cases in 5127 HBsAg negative serum samples. A total of 461 (89.5%) blood units were reactive for at least one additional serologic parameter and 54 were (10.5%) negative. Isolated anti-HBc positivity rate was 1.3% (69/5127). In the isolated anti-HBc positive samples, 54 were also anti-HBe and HBeAg negative. HBV DNA was not detected in any of the samples. Applying the EDQM criteria would decrease our blood donor loss from 10% to 5.4%. As alternative re-entry mechanisms have already been presented in the literature, institution of a new policy is needed to enhance the limited blood donor pool in our system. Copyright © 2016. Published by Elsevier Ltd.
21 CFR 1271.75 - How do I screen a donor?
Code of Federal Regulations, 2010 CFR
2010-04-01
...) REGULATIONS UNDER CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES..., you must screen a donor of cells or tissue by reviewing the donor's relevant medical records for: (1...) Communicable disease risks associated with xenotransplantation. (b) Donors of viable, leukocyte-rich cells or...
21 CFR 1271.75 - How do I screen a donor?
Code of Federal Regulations, 2014 CFR
2014-04-01
...) REGULATIONS UNDER CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES..., you must screen a donor of cells or tissue by reviewing the donor's relevant medical records for: (1...) Communicable disease risks associated with xenotransplantation. (b) Donors of viable, leukocyte-rich cells or...
Blood Donor Test-Seeking Motivation and Prior HIV Testing Experiences in São Paulo, Brazil.
Truong, Hong-Ha M; Blatyta, Paula F; Santos, Fernanda M; Montebello, Sandra; Esposti, Sandra P D; Hangai, Fatima N; Salles, Nanci Alves; Mendrone, Alfredo; Sabino, Ester C; McFarland, Willi; Gonçalez, Thelma T
2015-09-01
HIV test-seeking behavior among blood donors has been observed worldwide and may pose a threat to the safety of the blood supply. We evaluated current test-seeking motivations and prior alternative HIV testing experiences among blood donors in São Paulo, Brazil. All candidate or potential blood donors were consecutively approached and recruited to participate in the study upon presentation at Fundação Pró-Sangue Hemocentro, the largest blood bank in Brazil. Participants were recruited between August 2012 and May 2013 after they were screened for donor eligibility. Questionnaires were administered through audio computer-assisted self-interview. Among 11,867 donors, 38 % previously tested for HIV apart from blood donation, of whom 47.7 % tested at public facilities and 2.7 % acknowledged getting tested for HIV as the primary reason for donating. Dissatisfaction with prior alternative testing experience was reported by 2.5 % of donors. Current test-seeking motivation was associated with dissatisfaction with prior alternative testing experience and testing at a public alternative facility. The most common reasons for dissatisfaction were too long of a wait to get tested and for results, counseling was too long, lack of privacy, and low confidence in the equipment and accuracy of the test. Lack of awareness about the availability of free and confidential public HIV testing services as well as dissatisfaction with past HIV testing and counseling experiences motivate some individuals to test at blood banks. Test-seeking behavior among blood donors may be best addressed by improving alternative testing programs, particularly with respect to time delays, privacy and perceptions about test accuracy. Educational campaigns on safe blood donation and HIV testing for diagnosis, risk counseling and referral to care are also needed for the general public and for health care providers.
Severe hypertriglyceridemia in Puerto Rico blood donors: a population study 2009-2011.
Morales-Borges, Raúl H; Merced, Carmen
2012-01-01
Puerto Rico blood donor issues has been identified in cases of severe hypertriglyceridemia presenting as turbid. Blood donations resulting in milky serum must be discarded. They are discarded because we cannot properly test the donation. This is the first report where we correlate turbidity and cardiovascular risk factors in the Puerto Rico population as well as blood types O and A, Rh (+) with dyslipidemia. Blood donors should be screened in more details regarding cardiovascular and metabolic risks to avoid problems with recruitment and retention strategies.
Janssen, M P; van Hulst, M; Custer, B
2017-08-01
The cost-utility of safety interventions is becoming increasingly important as a driver of implementation decisions. The aim of this study was to compare the cost-utility of different blood screening strategies in various settings, and to analyse the extent and cause of differences in health economic results. For eight Western countries (Australia, Canada, Denmark, Finland, France, The Netherlands, UK and the United States of America), data were collected on donor and recipient populations, blood products, screening tests, and on patient treatment practices and costs. An existing ISBT web-tool model was used to assess the cost-utility of various strategies for HIV, HCV and HBV screening. The cost-utility ratio of serology screening for these eight countries ranges between -11 000 and 92 000 US$ per QALY, and for NAT between -12 000 and 113 000 US$ per QALY when compared to no screening. Combined serology and NAT ranges between 600 and 217 000 US$ per QALY. The incremental cost-utility of NAT after implementation of serology screening ranges from 2 231 000 to 15 778 000 US$ per QALY. There are substantial differences in costs per QALY between countries for various HIV, HBV and HCV screening strategies. These differences are primarily caused by costs of screening tests and infection rates in the donor population. Within each country, similar cost per QALY results for serology and NAT compared to no screening, coupled with evidence of limited value of serology and NAT together prompts the need for further discussion on the acceptability of parallel testing by serology and NAT. © 2017 International Society of Blood Transfusion.
Kitchen, A D; Newham, J A
2011-05-01
Whilst some of the assays used for serological screening of post-mortem blood samples from deceased tissue donors in some countries have been specifically validated by the manufacturer for this purpose, a significant number of those currently in use globally have not. Although specificity has previously been considered a problem in the screening of such samples, we believe that ensuring sensitivity is more important. The aim of this study was to validate a broader range of assays for the screening of post-mortem blood samples from deceased tissue donors. Six microplate immunoassays currently in use within National Health Service Blood and Transplant (NHSBT) for the screening of blood, tissue and stem cell donations were included. Representative samples from confirmed positive donors were titrated in screen negative post-mortem samples in parallel with normal pooled negative serum to determine if there was any inhibition with the post-mortem samples. There were no significant differences seen (P < 0.005) between the dilution curves obtained for the positive samples diluted in post-mortem samples and normal pooled sera. Although small numbers of samples were studied, it can be surmised that the post-mortem blood samples from deceased tissue donors, collected according to United Kingdom guidelines, are a suitable substrate for the assays evaluated. No diminution of reactivity was seen when dilution with sera from deceased donors was compared to dilution using pooled serum from live donors. In the absence of genuine low titre positive post-mortem samples, the use of samples spiked with various levels of target material provides a means of qualifying serological screening assays used by NHSBT for the screening of post-mortem blood samples from deceased tissue donors.
21 CFR 610.40 - Test requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
...; (3) Hepatitis B virus; (4) Hepatitis C virus; (5) Human T-lymphotropic virus, type I; and (6) Human T-lymphotropic virus, type II. (b) Testing using one or more approved screening tests. To test for evidence of... single identified recipient under paragraphs (a), (b), and (e) of this section; except that, if the donor...
Shahshahani, Hayedeh J; Meraat, Nahid; Mansouri, Fatemeh
2013-07-01
Haemoglobin screening methods need to be highly sensitive to detect both low and high haemoglobin levels and avoid unnecessary rejection of potential blood donors. The aim of this study was to evaluate the accuracy of measurements by HemoCue in blood donors. Three hundred and fourteen randomly selected, prospective blood donors were studied. Single fingerstick blood samples were obtained to determine the donors' haemoglobin levels by HemoCue, while venous blood samples were drawn for measurement of the haemoglobin level by both HemoCue and an automated haematology analyser as the reference method. The sensitivity, specificity, predictive values and correlation between the reference method and HemoCue were assessed. Cases with a haemoglobin concentration in the range of 12.5-17.9 g/dL were accepted for blood donation. Analysis of paired results showed that haemoglobin levels measured by HemoCue were higher than those measured by the reference method. There was a significant correlation between the reference method and HemoCue for haemoglobin levels less than 12.5 g/dL. The correlation was less strong for increasing haemoglobin levels. Linear correlation was poor for haemoglobin levels over 18 g/dL. Thirteen percent of donors, who had haemoglobin levels close to the upper limit, were unnecessarily rejected. HemoCue is suitable for screening for anaemia in blood donors. Most donors at Yazd are males and a significant percentage of them have haemoglobin values close to the upper limit for acceptance as a blood donor; since these subjects could be unnecessarily rejected on the basis of HemoCue results and testing with this method is expensive, it is recommended that qualitative methods are used for primary screening and accurate quantitative methods used in clinically suspicious cases or when qualitative methods fail.
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2010 CFR
2010-04-01
... includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds...). Except when used in donor screening tests, unassayed material is exempt from the premarket notification...
[Alanine aminotransferase (ALAT, GPT): a reevaluation of exclusion limits for blood donors].
Grunenberg, R; Banik, N; Krüger, J
1995-06-01
The screening policy of alanine aminotransferase (ALT) testing in blood donors was reassessed. The cutoff value for ALT levels according to German guidelines has always been controversial. In this study the activity and distribution of ALT in a blood donor population were reevaluated and new exclusion levels were defined. 5,706 blood donors were tested for ALT activities with the Reflotron system at 37 degrees C. Donors with ALT levels > 51 IU/l were deferred, a detailed physical examination and additional serologic and biochemical testing were done. ALT values of blood donors were transformed in logarithmic values in order to get a Gaussian distribution. The mean transformed value +/- SD was calculated with 1.24 +/- 0.14 for females and with 1.35 +/- 0.16 for males, corresponding to mean values of ALT activity of 17.6 and 22.5 IU/l, respectively. Exclusion levels of > 33.4 IU/l for female and > 46.7 IU/l for male blood donors (geometric mean +2.0 SD) predict a loss of donations of 2.8 and 2.7%, respectively, cutoff values of > 39.1 or > 56.1 IU/l (geometric mean +2.5 SD) a loss of 1.8 and 1.4%, respectively. The most likely causes of elevated ALT levels in 166 of our donors included daily alcohol use (82), infections with/without antibiotic medication (29), therapy with hepatotoxic drugs (8), strenuous exercises (5), bodybuilding complemented by anabolic steroids (2), acute infections with HCV (1), HBV (1) and CMV (1), alcohol/drug abuse and detection of HCV antibodies (1). ALT screening is still considered a useful indicator of risk donors despite its nonspecificity and limited predictive value. The selection of the appropriate cutoff value has always been disputed. The present exclusion level of > 45 IU/l (25 degrees C), analogous to > 81.8 IU/l (37 degrees C), does not even take into account such a variable as sex. The cutoff value above 4.5 SD of the geometric mean for females and above 3.5 SD for males seems to be of limited medical and practical value.
Apheresis for Collection of Ebola Convalescent Plasma in Liberia
Brown, Jerry F.; Rowe, Kathleen; Zacharias, Peter; van Hasselt, James; Dye, John M.; Wohl, David A.; Fischer, William A.; Cunningham, Coleen K.; Thielman, Nathan M.; Hoover, David L.
2017-01-01
Purpose This report describes initiation of apheresis capability in Liberia, Africa to support a clinical trial of convalescent plasma therapy for Ebola Virus Disease. Methods A bloodmobile was outfitted in the United States as a four-bed apheresis unit with capabilities including pathogen reduction, electronic blood establishment computer system, designated areas for donor counseling and laboratory testing, and onboard electrical power generation. After air transport to Liberia, the bloodmobile was positioned at ELWA Hospital, Monrovia, and connected to the hospital’s power grid. Liberian staff were trained to conduct donor screening, which included questionnaire and onsite blood typing and transfusion transmitted infection (TTI) testing, and plasma collection and processing. Results The bloodmobile was operational within three weeks after arrival of the advance team. Of 101 donors who passed the pre-screening questionnaire, 32 were deferred. Twenty-eight of 99 tested survivors were deferred for positive transfusion transmitted infection (TTI) tests; 21 were positive for hepatitis B, hepatitis C, or human immunodeficiency virus. The majority of donors had type O blood; all but one were Rh positive. Forty-three survivors donated at least once; 89 apheresis attempts resulted in 81 successful collections. Conclusions Apheresis capability was emergently established in Liberia to support an efficacy trial of Ebola Convalescent Plasma. Extensive cooperation among multinational team members, engineers, logisticians and blood safety technical personnel at the operational site was required to surmount challenges to execution posed by logistical factors. The high proportion of positive TTI tests supported the use of a pathogen reduction system to enhance product safety. PMID:27393614
Brailsford, S R; Tossell, J; Morrison, R; McDonald, C P; Pitt, T L
2018-05-24
Between February 2011 and December 2016, over 1·6 million platelet units, 36% pooled platelets, underwent bacterial screening prior to issue. Contamination rates for apheresis and pooled platelets were 0·02% and 0·07%, respectively. Staphylococcus aureus accounted for 21 contaminations, including four pooled platelets, one confirmed transfusion-transmitted infection (TTI) and three 'near-miss' incidents detected on visual inspection which were negative on screening. We describe follow-up investigations of 16 donors for skin carriage of S. aureus and molecular characterisation of donor and pack isolates. Units were screened by the BacT/ALERT 3D detection system. Contributing donors were interviewed and consent requested for skin and nasal swabbing. S. aureus isolates were referred for spa gene type and DNA macrorestriction profile to determine identity between carriage strains and packs. Donors of 10 apheresis and two pooled packs screen positive for S. aureus were confirmed as the source of contamination; seven had a history of skin conditions, predominantly eczema; 11 were nasal carriers. The 'near-miss' incidents were associated with apheresis donors, two donors harboured strains indistinguishable from the pack strain. The TTI was due to a screen-negative pooled unit, and a nasal isolate of one donor was indistinguishable from that in the unit. Staphylococcus aureus contamination is rare but potentially harmful in platelet units. Donor isolates showed almost universal correspondence in molecular type with pack isolates, thus confirming the source of contamination. The importance of visual inspection of packs prior to transfusion is underlined by the 'near-miss' incidents. © 2018 International Society of Blood Transfusion.
Newman-Gage, H; Bravo, D; Holmberg, L; Mason, J; Eisenhower, M; Nekhani, N; Fantel, A
2000-01-01
We initiated this study to evaluate the suitability for therapeutic use in transplantation of tissues obtained from human abortuses. We have developed protocols for the collection, handling and preservation of hepatic stem cells from electively aborted embryos and have developed methods for assessment of the cells so derived and processed. In this paper we present our findings regarding screening of potential donors, acquisition of fetal tissues, and assessment of the tissues for potentially infectious contaminants. We assess the suitability of the tissue donors according to current standards used for donors of commonly transplanted tissues (e.g., bone grafts, skin grafts and heart valves) and present data regarding the real availability of tissues from elective abortion procedures that would meet those standard tissue banking criteria.We specifically evaluated the donor's willingness to provide a blood sample for testing, conducted a detailed interview similar to those used for typical organ and tissue donors, and assessed the type and incidence of contamination in collected tissues. We find that although many women are willing to consent to use of the tissues for transplantation, attrition from the study for various reasons results in few fetal organs ultimately realistically available for transplantation. Typical reasons for attrition include: unwillingness to have a blood sample drawn or tested, positive serology results, social/medical high risk factors for acquisition of transmissible disease, no identifiable organs available, and unacceptable microbial contamination. Thus, although it might seem that due to the numbers of abortions performed annually, that there would be substantial numbers of suitable tissues available, only a small proportion are truly suitable for transplantation.
Ferreira, Oranice; Passos, Afonso Dinis Costa
2012-01-01
Objective This study aimed to investigate the frequency of positive results for hepatitis B and C, HIV and syphilis in blood donations at the Centro Regional de Hemoterapia de Ribeirão Preto, to describe donors with positive results according to some demographic and socioeconomic variables, to identify risk factors associated to these donors and the reasons that they were not detected during clinical screening. Methods A descriptive study was performed between July 1st 2005 and July 31st 2006 by interviewing 106 donorsafter medical consultations where they were informed of positive results for hepatitis B, hepatitis C, HIV or syphilis. Results There was a predominance of first-time donors, males, under 50-year olds, married individuals, from Ribeirão Preto, with elementary education, low economic status and of people who donated at the request of friends or relatives. Hepatitis C was the most frequently detected infection (56.6%), followed by hepatitis B (20.7%), HIV (12.3%) and syphilis(10.4%). About 40% of donors had omitted risk factors for different reasons: because they trusted the results of serological tests, did not feel comfortable about talking of risk factors or did not consider them relevant. Other justifications were the duration of the interview, the interviewer was unskilled, embarrassment and doubts about confidentiality. Conclusion The results indicate the need for changes in the approach to clinical screening and a review of methods to attract and guide potential donors. PMID:23323063
Hepatitis B Virus Blood Screening: Need for Reappraisal of Blood Safety Measures?
Candotti, Daniel; Laperche, Syria
2018-01-01
Over the past decades, the risk of HBV transfusion–transmission has been steadily reduced through the recruitment of volunteer donors, the selection of donors based on risk-behavior evaluation, the development of increasingly more sensitive hepatitis B antigen (HBsAg) assays, the use of hepatitis B core antibody (anti-HBc) screening in some low-endemic countries, and the recent implementation of HBV nucleic acid testing (NAT). Despite this accumulation of blood safety measures, the desirable zero risk goal has yet to be achieved. The residual risk of HBV transfusion–transmission appears associated with the preseroconversion window period and occult HBV infection characterized by the absence of detectable HBsAg and extremely low levels of HBV DNA. Infected donations tested false-negative with serology and/or NAT still persist and derived blood components were shown to transmit the virus, although rarely. Questions regarding the apparent redundancy of some safety measures prompted debates on how to reduce the cost of HBV blood screening. In particular, accumulating data strongly suggests that HBsAg testing may add little, if any HBV risk reduction value when HBV NAT and anti-HBc screening also apply. Absence or minimal acceptable infectious risk needs to be assessed before considering discontinuing HBsAg. Nevertheless, HBsAg remains essential in high-endemic settings where anti-HBc testing cannot be implemented without compromising blood availability. HBV screening strategy should be decided according to local epidemiology, estimate of the infectious risk, and resources. PMID:29515997
Clemente, W T; Rabello, A; Faria, L C; Peruhype-Magalhães, V; Gomes, L I; da Silva, T A M; Nunes, R V P; Iodith, J B; Protil, K Z; Fernandes, H R; Cortes, J R G; Lima, S S S; Lima, A S; Romanelli, R M C
2014-01-01
Visceral leishmaniasis is an uncommon disease in transplant recipients; however, if left untreated, the mortality can be high. If an organ donor or recipient is known to be an asymptomatic Leishmania spp. carrier,monitoring is advised. This study proposes to assess the prevalence of asymptomatic Leishmania spp.infection in liver transplant donors and recipients from an endemic area. A total of 50 liver recipients and 17 liver donors were evaluated by direct parasite search, indirect fluorescent antibody test (IFAT), anti-Leishmania rK39 rapid test and Leishmania spp.DNA detection by polymerase chain reaction (PCR).Leishmania spp. amastigotes were not observed in liver or spleen tissues. Of the 67 serum samples, IFAT was reactive in 1.5% and indeterminate for 17.9%, and the anti-Leishmania rK39 rapid test was negative for all samples. The PCR test was positive for 7.5%, 8.9%, and 5.9% of blood, liver and spleen samples, respectively(accounting for 23.5% of the donors and 8% of the recipients). Leishmania infantum-specific PCR confirmed all positive samples. In conclusion, a high prevalence of asymptomatic L. infantum was observed in donors and recipients from an endemic area, and PCR was the most sensitive method for screening these individuals.
Emerging Infectious Threats to the Blood Supply: Seroepidemiological Studies in Iran – a Review
Karimi, Gharib; Gharehbaghian, Ahmad; Tafti, Mohammad Fallah; Vafaiyan, Vida
2013-01-01
Summary The risk of transfusion-transmitted infections has been greatly reduced by improvements in donor screening and testing. However, newly recognized blood-borne infectious agents can be threats to blood safety. In order to evaluate the prevalence some of these agents in blood donors, a systematic review was conducted. Data were obtained from published papers related to HGV, Torque Teno virus (TTV), HTLV, West Nile virus (WNV) and SEN virus (SEN-V). Based on these studies, the prevalence of HGV varied from 1 to 8.6% for anti-E2 and from 0 to 4.8% for HGV RNA. The prevalence of TTV DNA and HTLV-I varied from 2.7 to 79.5% and from 0.013 to 2.3%, respectively. The WNV-specific IgM antibody and WNV RNA are negative in blood donors. Prevalence rates of SEN-V in Iranian blood donors range from 23 to 90.8%. Consequences of these infectious agents for blood safety are different. Thus, the need to perform laboratory screening as well as effectiveness and efficiency of laboratory tests depend on pathogenicity level and epidemiological conditions of emerging infections. However, being prepared based on the current level of risk and interventions to reduce the risk can be effective in reducing the potential threat for blood supply. PMID:23922546
Chmielewski, Danielle; Bove, Liliana L; Lei, Jing; Neville, Ben; Nagpal, Anish
2012-09-01
The Motivation Crowding-out Theory suggests that incentives undermine intrinsic motivation and thus blood donation behavior. While there is strong evidence showing the negative relationship between monetary incentives and blood donation, findings on the effect of nonmonetary incentives are mixed. Set in a voluntary, nonremunerated environment, this study explores aspects of the nonmonetary incentive-blood donation relationship not captured by the crowding-out hypothesis. In-depth interviews were conducted to explore donors' attitudes toward nonmonetary incentives currently used or considered by the Australian Red Cross Blood Service (Blood Service). Transcripts were analyzed using an inductive, thematic approach. Of the nonmonetary incentives examined (i.e., health screening tests, branded tokens, paid time off work, recognition of key milestones, and postdonation refreshments), none were found to crowd out intrinsic motivation, although not all were viewed favorably. Donors who viewed branded tokens negatively considered the cost implications for the Blood Service, while donors who responded positively considered the public benefit of tokens in raising the profile of the Blood Service. Other nonmonetary incentives-paid time off work, postdonation refreshments, and health screening tests-were viewed positively because donors perceived them to be congruent to the effort expended in donating blood. Finally, donors expressed a preference for private over public recognition when acknowledging significant contributions. When operating in a voluntary, nonremunerated environment, blood services should view donors as supply partners rather than customers, only consider nonmonetary incentives that are congruent with the act of donation, and provide private rather than public recognition of key milestones. © 2012 American Association of Blood Banks.
Ashshi, Ahmed M; Alghamdi, Saad; El-Shemi, Adel G; Almdani, Sabir; Refaat, Bassem; Mohamed, Amr M; Ghazi, Hani O; Azhar, Esam I; Al-Allaf, Faisal A
2017-01-01
Threat to blood transfusion-transmitted dengue virus (DENV) and its antibodies has recently emerged worldwide. Dengue fever is an endemic disease in Saudi Arabia, particularly in its Western region. The aim of this study was to estimate the seroprevalence of asymptomatic DENV infection and its antibodies among eligible Saudi blood donors. Serum samples from 910 healthy/eligible adult male Saudi blood donors, who reside in Holy Makkah City of Saudi Arabia, were collected between March 2015 and August 2016 and screened for the detection of DENV nonstructural protein 1 (NS1) antigen and anti-DENV IgM and IgG antibodies using commercial enzyme-linked immunosorbent assay kits (Panbio, Brisbane, QLD, Australia). Among the tested donors, 48 (5.3%) were seropositive for DENV-NS1 antigen, whereas 50 (5.5%) and 354 (38.9%) were seropositive for anti-DENV IgM and IgG antibodies, respectively. Seropositivity for DENV-NS1 antigen and/or anti-DENV IgM antibody among the tested donors reflects their ongoing asymptomatic viremic infectious stage with DENV during their donation time, whereas high prevalence of anti-DENV IgG seropositivity reflects the high endemicity of dengue disease in this region of Saudi Arabia. These results show high prevalence of asymptomatic DENV infection and its antibodies among Saudi blood donors, raising the importance of establishing blood screening for dengue disease at different blood donation services and units in Saudi Arabia to improve the guarantee of blood transfusions and to control DENV dissemination.
Chiodini, P L; Hartley, S; Hewitt, P E; Barbara, J A; Lalloo, K; Bligh, J; Voller, A
1997-01-01
Blood donations are often wasted for lack of a satisfactory procedure to evaluate donors potentially exposed to malaria. We evaluated a commercial ELISA for the detection of antibodies to malaria and compared it with an immunofluorescent antibody test (IFAT). When 5,311 sera from routine non-exposed donors were tested, 24 (0.45%) were positive by the ELISA, using a Plasmodium falciparum antigen. Seventeen were subjected to confirmatory testing but none were positive by IFAT. Of 1,000 donors potentially exposed in endemic areas 15 (1.5%) were repeatably reactive by ELISA. 10 of these were tested by IFAT and 2 were positive. When 150 patients attending the Hospital for Tropical Diseases in London with acute malaria were tested, 73% of those infected with P. falciparum were repeatably reactive for malarial antibodies by ELISA and 56% with Plasmodium vivax. Of 88 stored clinical sera tested by both IFAT and ELISA 56 were positive by IFAT and of these 52 (93 degrees/0) were positive by ELISA. The ELISA is sufficiently sensitive and specific to screen at-risk donors. Its use could safely retrieve 40,000 red cell units currently discarded each year in Great Britain.
Serologic screening for Trypanosoma cruzi among blood donors in central Brazil.
de Andrade, A L; Martelli, C M; Luquetti, A O; de Oliveira, O S; Almeida e Silva, S; Zicker, F
1992-01-01
The study reported here compares results obtained by blood banks screening sera for chagasic (Trypanosoma cruzi) infection with results obtained by the Chagas' Disease Reference Laboratory of the Federal University of Goiás in Goiânia, Brazil. It also evaluates results obtained using the ELISA technique to screen the study sera. The survey used data from six of eight blood banks serving the city of Goiânia, an urban region of Central Brazil where Chagas' disease is highly endemic. The survey population consisted of 1,513 voluntary first-time blood donors whose donations occurred between October 1988 and April 1989. This group included 50% of all the first-time blood donors in that period. The six participating blood banks, which accounted for about 90% of all blood donations in Goiânia during the study period, routinely used indirect hemagglutination (IHA) and complement fixation (CF) tests to screen sera for antibodies to T. cruzi. Comparison of the results provided by the blood banks with the reference laboratory's results indicated a relative sensitivity of 77%, which ranged from 50% to 100% depending on the blood bank studied. The comparison, which found 12 false negative results, indicated that transfusions of infected blood might have occurred despite the serologic screening performed by the blood banks. Relative to the standard of positivity established for the study, the enzyme-linked immunosorbent assay (ELISA) technique was found to have a sensitivity of 96.3%. Considering as positive only those sera yielding positive IHA and indirect immunofluorescence (IIF) test results, the ELISA technique yielded 2 false negative and 41 false positive responses.(ABSTRACT TRUNCATED AT 250 WORDS)
Nucleic acid testing: Is it the only answer for safe Blood in India?
Naidu, N. K.; Bharucha, Z. S.; Sonawane, Vandana; Ahmed, Imran
2016-01-01
Background: With the implementation of NAT in countries around the world, there is a growing pressure on the transfusion services in India to adopt NAT testing. India has about 2545 licensed Blood Centres. The Transfusion Services in India are fragmented, poorly regulated and the quality standards are poorly implemented. Blood Centres are still dependent on replacement/family donors and in most places laboratory testing for Transfusion transmitted infections is not quality assured, laboratory equipment are not calibrated and maintained, and validation of results is not carried out. Against the current scenario introducing NAT for screening of blood donors in India would pose a challenge. Aim: To study the prudence of universal NAT testing in India. Materials and Methods: A retrospective study of 5 years from 2008-2012 was undertaken to study the true reactivity of donors using WHO strategy II and III and therefore the true seroprevalence of TTI infections in the donor populations. Results: The true reactivity of the donors was much less as compared to the initially reactive donors due to the use of a well designed testing algorithm. In addition having a total voluntary blood collection along with good pre-donation counseling program also reduces the transmission of infections. Conclusions: What India essentially needs to do is religiously implement the strategies outlined in the WHO Aide-memoire. The blood should be collected only from voluntary non remunerative and repeat donors, there should be stringent donor selection with pre-donation counseling instituted. Strict implementation of quality management system, development of well defined testing startegies and strong haemovigilance system could take us a step in the right direction. PMID:27011677
Cruz, Jose R; Pérez-Rosales, Maria Dolores; Zicker, Fabio; Schmunis, Gabriel A
2005-12-01
Blood transfusions carry risks of untoward reactions, including the transmission of infections, such as hepatitis B and C. Proper blood donor recruitment and selection, and adequate laboratory screening for infectious markers diminish the risk of transfusion-transmitted infections. To estimate the potential risk of acquiring transfusion-transmitted infections by hepatitis B or hepatitis C in 24 Caribbean countries during the period of 1996 to 2003. Official national reports for 1996, 2000-2003 of the yearly number of blood donors, screening coverage, and prevalence of serological markers for infectious diseases were used to estimate the risk of patients receiving an HBV- or HCV-positive unit of blood, and of developing an infection after receiving a positive unit. Estimates of number of infections transmitted through transfusion and number of infections prevented by screening of blood were also obtained. During the period analyzed, HBV screening coverage among blood donors was 100% in all countries with the exception of Grenada (0% in 1996) and Saint Lucia (99.5% in 2002). For HCV, only 10 countries reported universal screening in 1996, while 15 did in 2003. The number of countries that did not screen any units for HCV decreased from 11 in 1996 to five in 2003. In general, high prevalence rates of HBV (10-75 per 1000 donors) and HCV (7-19.3 per 1000 donors) markers were found in the majority of countries. We estimated that 235 infections by HCV (1:12471 donations) and two infections by HBV (1:1465373) were transmitted through transfusion because of lack of screening. On the other hand, screening of blood for transfusion prevented 21 005 HCV and 22 100 HBV infections. Blood donor recruitment and coverage of screening for transfusion-transmitted infections, especially HCV, must be improved in the Caribbean countries.
New screening methods for donor eye-bank eyes.
Terry, M A; Ousley, P J
1999-07-01
Current methods of screening donor eyes for corneal transplantation are not always effective in excluding corneas with abnormal topography. We used the Orbscan to determine whether corneal-thickness maps could be used as a technique for donor tissue screening. Forty eye-bank eyes were measured with the Orbscan, and a corneal-thickness map was generated. Average central pachymetry measurements from each map were compared with the thinnest midperipheral thickness reading. Two eyes from a donor who had photorefractive keratectomy (PRK) and two eyes from a donor with keratoconus were then compared with the normal donor eye results. The average difference between the thinnest midperipheral pachymetry and the central pachymetry in the control group was 0.040 +/- 0.026 mm. The eyes from the donor with PRK showed larger disparities between the central and midperipheral thicknesses because of the thinned central cornea, with differences of 0.154 mm in the right eye and 0.106 mm in the left eye. The eyes from the donor with keratoconus had midperipheral corneas that were thinner than the center, indicating eccentric, ectatic cones. The differences in thickness between the center and midperiphery in the eyes from the donor with PRK and the donor with keratoconus differed from the control group by >2 SD. Diseases or surgery that affect the relationship between the central and midperipheral corneal thickness may be screened through Orbscan pachymetry mapping with comparison with a normal range.
Contreras, C E; Pance, A; Marcano, N; González, N; Bianco, N
1999-06-01
Malaria antibody detection is valuable in providing retrospective confirmation of an attack of malaria. Blood bank screening is another area were malaria serology is potentially useful. In the present study, we tested the presence of antibodies to Plasmodium falciparum in sera from blood bank donors of non-endemic and malaria-endemic areas of Venezuela. Sera from 1,000 blood donors were tested by an indirect immunofluorescent antibody (IFA) assay and an IgG-ELISA for the presence of malaria antibodies using a synchronized in vitro-cultured Venezuelan isolate of P. falciparum as the antigen source. A selected group of positive and negative sera (n = 100) was also tested by a dot-IgG-ELISA. Positive results (reciprocal titer > or = 40) were found in 0.8% and 3.8% of blood donors when tested by the IFA assay and in 0.8% and 2% (optical density > or = 0.2) when tested by the IgG-ELISA in Caracas (non-endemic area) and Bolivar City (endemic area), respectively. The presence of anti-malarial antibodies in some sera from non-endemic areas such as Caracas reflects the increased potential risk of post-transfusional malaria in those areas due to the mobility of the blood donors. The data obtained indicate the need to implement new blood donor policy in blood banks in developing areas. Our results also indicate that the IFA assay is the most reliable test to use in malaria serodiagnosis.
Barriers to the use of a federal travel grant by living kidney donors.
Hays, Rebecca E; Thomas, Amy Elaine; Mathias, Erin; Mezrich, Joshua; Mandelbrot, Didier A
2017-02-01
Living organ donation involves significant out-of-pocket costs, which burden donor candidates and may be an obstacle to donation. There is a single US grant (the National Living Donor Assistance Center-NLDAC) to cover live donor travel costs. Although there may be center-specific variability in grant utilization, prospective donors-and their intended recipients-must also meet eligibility criteria. In fact, the NLDAC grant is used by <10% of US live donors annually. We studied 154 consecutive kidney donor clinic evaluations (November 1, 2014-August 30, 2015) to determine eligibility and usage patterns during the evaluation process. Of these, 63 (41%) were local, had travel benefits, or declined. Of the remaining 91 prospective donors who might have benefited from grant support, only 29 (32%) obtained the grant. The other 62 (68%) did not meet eligibility screening. The major reason prospective donors were ineligible was that the recipient's household income was outside the required means test (ie, >300% of the federal poverty level) (n=51; 82%). The remaining exclusions (n=11; 18%) included being a nondirected donor, not meeting residency requirements, and "other." Expanding NLDAC eligibility criteria-by broadening the recipient means test or by taking steps to eliminate it from the NLDAC charter-would reduce financial burdens associated with live donation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Apheresis for collection of Ebola convalescent plasma in Liberia.
Brown, Jerry F; Rowe, Kathleen; Zacharias, Peter; van Hasselt, James; Dye, John M; Wohl, David A; Fischer, William A; Cunningham, Coleen K; Thielman, Nathan M; Hoover, David L
2017-06-01
This report describes initiation of apheresis capability in Liberia, Africa to support a clinical trial of convalescent plasma therapy for Ebola Virus Disease. A bloodmobile was outfitted in the United States as a four-bed apheresis unit with capabilities including pathogen reduction, electronic blood establishment computer system, designated areas for donor counseling and laboratory testing, and onboard electrical power generation. After air transport to Liberia, the bloodmobile was positioned at ELWA Hospital, Monrovia, and connected to the hospital's power grid. Liberian staff were trained to conduct donor screening, which included questionnaire and onsite blood typing and transfusion transmitted infection (TTI) testing, and plasma collection and processing. The bloodmobile was operational within 3 weeks after arrival of the advance team. Of 101 donors who passed the pre-screening questionnaire, 32 were deferred. Twenty-eight of ninty-nine tested survivors were deferred for positive transfusion transmitted infection (TTI) tests; twenty-one were positive for hepatitis B, hepatitis C, or human immunodeficiency virus. The majority of donors had type O blood; all but one were Rh positive. Forty-three survivors donated at least once; eighty-nine apheresis attempts resulted in eighty-one successful collections. Apheresis capability was emergently established in Liberia to support an efficacy trial of Ebola Convalescent Plasma. Extensive cooperation among multinational team members, engineers, logisticians, and blood safety technical personnel at the operational site was required to surmount challenges to execution posed by logistical factors. The high proportion of positive TTI tests supported the use of a pathogen reduction system to enhance product safety. J. Clin. Apheresis 32:175-181, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham
2012-01-01
The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.
Prevention of blood-borne HIV transmission using a decentralized approach in Shaba, Zaire.
Laleman, G; Magazani, K; Perriëns, J H; Badibanga, N; Kapila, N; Konde, M; Selemani, U; Piot, P
1992-11-01
To prevent blood transfusion-acquired HIV infection with a decentralized approach to HIV screening of blood donors, using an instrument-free rapid test. Shaba province, Zaire (496,877 km2). The programme consisted of training health-care workers, distribution of a rapid HIV-antibody test (DuPont's HIVCHEK) for screening of all blood donations, and quality control of testing by a regional reference centre. Over a 2-year period, 11,940 rapid tests were distributed to 37 hospitals, covering 75% of all hospital beds outside the copper mine's health system in Shaba. Eighty-five per cent of the tests were used to screen blood donors (5.4% positive test rate) and 13% to test patients (39.7% positive test rate). At least 265 cases of HIV-positive blood donation were prevented, at an estimated cost of 137-279 ECU per case. Only 26% of initially positive specimens reached the central laboratory for supplemental testing, and sterile transfusion equipment and blood-grouping reagents were frequently unavailable. The lack of transport and communications and a deteriorating health system were major constraints. District hospitals in Africa are often long distances from major cities, difficult to reach for most of the year, and perform a small number of transfusions. In this context a classical centralized regional blood bank may not be a feasible option to ensure safe blood transfusions. However, safe blood transfusion can be achieved with a decentralized approach using a rapid test, provided that minimum standards of health-care services are available.
Antibody screening in multitransfused patients: a prerequisite before each transfusion.
Lamba, Divjot S; Mittal, Kshitija; Sood, Tanvi; Bedi, Ravneet Kaur; Kaur, Paramjit; Kaur, Gagandeep
2014-10-01
Life-long red blood cell (RBC) transfusions remain the main treatment for severe thalassemia. We hereby report a case of anti S and anti Lu(a) in a β-thalassemia major patient detected incidentally on antibody screening. The patient was a known case of β-thalassemia major and was on regular blood transfusion every 3 weeks from the institute from the age of 6 months. Subsequently, on one occasion, patient's crossmatch was compatible despite positive antibody screen using microcolumn gel technique. Autocontrol and direct antiglobulin test were negative on microcolumn gel. Anti S and anti Lu(a) antibodies were identified. Blood unit found compatible was negative for S and Lu(a) antigens. Antibody titers were 1:1 for both anti S and anti Lu(a) in AHG phase using tube technique and antibodies were of IgG type. Blood unit was transfused uneventfully to the patient. Donors were traced back (last three donations) and called for repeat blood sample testing for S and Lu(a) antigen. Two out of three donors were found to be S antigen positive and one out of these two was Lu(a) antigen positive. Anti S and anti Lu(a) antibodies were again identified on patient's subsequent visit for transfusion. The present case re-emphasize the importance of antibody screening at each visit in earlier detection of antibodies in multi transfused patients. Encouraging patients to receive transfusion from one center and dedicating donors could reduce alloimmunization rate but larger studies are required. Copyright © 2014 Elsevier Ltd. All rights reserved.
Establishing Assay Cutoffs for HLA Antibody Screening of Apheresis Donors
Carrick, Danielle M.; Norris, Philip J.; Endres, Robert O.; Pandey, Suchitra; Kleinman, Steven H.; Wright, David; Sun, Yu; Busch, Michael P.
2011-01-01
BACKGROUND TRALI is the leading cause of transfusion-related deaths. Donor HLA antibodies have been implicated in TRALI cases. Blood centers are implementing TRALI risk reduction strategies based on HLA antibody screening of some subpopulations of ever-pregnant apheresis platelet donors. However, if screening assay cutoffs are too sensitive, donation loss may adversely impact blood availability. STUDY DESIGN Pregnancy history and HLA antibody screening and single antigen bead (SAB) data from blood donors in the REDS-II Leukocyte Antibody Prevalence Study (LAPS) were evaluated for correlations between assay screening values, HLA antibody titer, and number of HLA antigen specificities. The probabilities of matching a cognate antigen in a recipient were calculated and examined in association with total number of specificities observed and screening values. The relative impact of imposing various screening assay cutoffs or pregnancy stratification was examined in relation to detection of HLA antibody reactive donations and loss of donors and donations. RESULTS We provide evidence that higher HLA Ab screening assay values are associated with maintaining higher screening signals upon dilution and an increased breadth of specificities compared with lower screening values; the latter correlated with an increased risk of a cognate antigen match in potential recipients. Depending upon the TRALI risk reduction strategy used, the potential loss of donations ranged between 0.9 and 6.0%. CONCLUSION This analysis should enable blood centers to decide upon a TRALI risk reduction strategy for apheresis platelets that is consistent with how much donation loss the blood center can tolerate. PMID:21332726
O'Brien, Sheila F; Fearon, Margaret A; Yi, Qi-Long; Fan, Wenli; Scalia, Vito; Muntz, Irene R; Vamvakas, Eleftherios C
2007-10-01
The benefit of introducing anti-hepatitis B core antigen (HBc) screening for intercepting potentially infectious donations missed by hepatitis B surface antigen (HBsAg) screening in Canada was studied. Anti-HBc testing of all donations was implemented in April 2005, along with antibody to hepatitis B surface antigen (anti-HBs) and hepatitis B virus (HBV) DNA supplemental testing of anti-HBc repeat-reactive, HBsAg-negative donations. The proportion of potentially infectious donations intercepted by anti-HBc over the initial 18 months of testing was calculated based on three assumptions relating infectivity of HBV DNA-positive units to anti-HBs levels. Lookback was conducted for all DNA-positive donations. Of 493,344 donors, 5,585 (1.13%) were repeat-reactive for the presence of anti-HBc, with 29 (0.52%) being HBV DNA-positive and HBsAg-negative. The proportion of potentially infectious donations intercepted by anti-HBc screening was 1 in 17,800 if all HBV DNA-positive donations were infectious, 1 in 26,900 if infectivity was limited to donations with an anti-HBs level of not more than 100 mIU per mL, and 1 in 69,300 if only donations with undetectable anti-HBs were infectious. For 279 components in the lookback study, no traced recipients were HBsAg-positive and 7 recipients were anti-HBc-reactive in association with 4 donors, 3 of whom had an anti-HBs level of more than 100 mIU per mL and 1 of whom had a level of 61 mIU per mL. Implementation of anti-HBc screening reduced the risk of transfusing potentially infectious units by at least as much as had been expected based on the literature. The lookback did not provide proof of transfusion transmission of HBV from HBV DNA-positive, anti-HBc-reactive, HBsAg-negative donors but it did not establish lack of transmission either.
Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.
Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan
2017-05-01
Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.
de Lima, Waleska Mayara Gomes; Esteves, Fabrício Andrade Martins; Torres, Maria do Carmo Morais Rodrigues; Pires, Edna Suely Feitosa
2013-01-01
There is difficulty in gathering data on the prevalence of human T-cell lymphotropic virus in blood donors as confirmatory testing is not mandatory in Brazil. This suggests there may be an underreporting of the prevalence. To estimate the prevalence of human T-cell lymphotropic virus types 1 and 2 in donors of a blood bank in Caruaru, Brazil. This was an observational, epidemiological, descriptive, longitudinal and retrospective study with information about the serology of donors of the Caruaru Blood Center, Fundação de Hematologia e Hemoterapia de Pernambuco (Hemope) from May 2006 to December 2010. The data were analyzed using the Excel 2010 computer program (Microsoft Office(®)). Of 61,881 donors, 60 (0.096%) individuals were identified as potential carriers of human T-cell lymphotropic virus types 1 and 2. Of these, 28 (0.045%) were positive and 32 (0.051%) had inconclusive results in the serological screening. Forty-five (0.072%) were retested; 17 were positive (0.027%) and 3 inconclusive (0.005%). After confirmatory tests, 8 were positive (0.013%). Six (75%) of the confirmed cases were women. Epidemiological surveys like this are very important in order to create campaigns to attract donors and reduce the costs of laboratory tests.
Timilsina, Suraj; Raj Bhattarai, Narayan; Khanal, Basudha; Rijal, Suman
2016-03-01
Visceral leishmaniasis (VL) is a major vector-borne disease caused by Leishmania donovani, after replication of the parasites in macrophages, mononuclear phagocytic system. VL is endemic in 12 districts of central and eastern Terai lowlands of Nepal bordering North Bihar, India with an estimated 8 million population at risk. In addition, VL endemicity is also extending to new endemic regions like Dharan from its classical rural foci. Hence, we aimed to detect the evidence of Leishmania donovani infection in the blood samples received from blood donors of Sunsari district, Dharan, (eastern Nepal), a region endemic for human VL. Sera from 507 asymptomatic blood donors were subjected to serological screening for anti-Leishmania donovani antibodies. Direct agglutination test (DAT) was performed on the sera. Out of 507 donors, majority (78.50 %) were male. Among the donors, 472 (93.10 %) belonged to age group 18-45 years where as 35 (6.90 %) to age group >45 years. Circulating anti-Leishmania antibodies were detected in 5 (1 %) out of 507 healthy, Human Immunodeficiency Virus types 1 and 2 (HIV 1and 2), Hepatitis B Surface Antigen (HBsAg), anti- Hepatitis C Virus (anti-HCV)-negative, and Syphillis non-reactive donors. All the seropositive cases were male and belonged to the age group 18-45 years. The result suggests that there is an immediate need of screening asymptomatic blood donors for leishmania seropositivity especially in endemic areas.
The effect of prior transfusion history on blood donor anti-hepatitis C virus antibody.
Mazda, T; Nakata, K; Ota, K; Kaminuma, Y; Katayama, T
1993-01-01
In Japan, the major transfusion-associated disease is non-A, non-B hepatitis. We studied the relationship between transfusion history and blood donor antibodies to hepatitis C virus (HCV). The positive rate of antibodies to the HCV nonstructural protein (c100-3) depended on age and the time elapsed since transfusion. The anti-c100-3 ratio for subjects with transfusions made prior to 20 years ago was high. One quarter century ago, a change occurred in national blood policy from paid to non-paid voluntary donations. We also have studied the anti-HCV positive rate among donors with prior transfusion using a second generation HCV test kit which includes anti-HCV core antibody detection. The anti-HCV positive rate for the second generation test was higher than that for the anti-c100-3 test. Introduction of the second generation test is therefore more useful in screening than the anti-c100-3 test for blood programs.
Germain, Marc; Delage, Gilles; Blais, Claudia; Maunsell, Elizabeth; Décary, Francine; Grégoire, Yves
2013-06-01
The theory that elevated iron stores can induce vascular injury and ischemia remains controversial. We conducted a cohort study of the effect of blood donation on the risk of coronary heart disease (CHD) by taking advantage of the quasi-random exclusion of donors who obtained a falsely reactive test for a transmissible disease (TD) marker. Whole blood donors who were permanently disqualified because of a false-reactive test between 1990 and 2007 in the province of Quebec were compared to donors who remained eligible, matched for baseline characteristics. The incidence of CHD after entry into the study was determined through hospitalization and death records. We compared eligible and disqualified donors using an "intention-to-treat" framework. Overall, 12,357 donors who were permanently disqualified were followed for 124,123 person-years of observation, plus 50,889 donors who remained eligible (516,823 person-years). On average, donors who remained eligible made 0.36 donation/year during follow-up and had an incidence of hospitalizations or deaths attributable to CHD of 3.60/1000 person-years, compared to 3.52 among permanently disqualified donors (rate ratio, 1.02; 95% confidence interval, 0.92-1.13). Donors who remained eligible did not have a lower risk of CHD, compared to donors who were permanently disqualified due to a false-reactive TD marker. Because of the quasi-random nature of false-reactive screening tests, this natural experiment has a level of validity approaching that of a randomized trial evaluating the effect of regular blood donation on CHD risk. These results do not support the iron hypothesis. © 2013 American Association of Blood Banks.
de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen
2014-04-01
Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.
Leiby, D A; Fucci, M H; Stumpf, R J
1999-03-01
Several recent studies documented the seroprevalence of Trypanosoma cruzi in blood donors at high risk for infection, but little information is available regarding donors with lower levels of risk. Thus, the present study was designed to measure the seroprevalence of T. cruzi in a donor population with a low to moderate risk for infection. During a 10-month period, donations from all allogeneic blood donors in the American Red Cross Southwest Region were tested for T. cruzi antibodies by enzyme immunoassay, and results were confirmed by radioimmunoprecipitation. Confirmed-seropositive donors were counseled and lookback investigations were initiated for those who were repeat donors. A total of 100,089 donations were tested: 150 were repeatably reactive, and 3 (0.003%) were confirmed as positive for T. cruziantibodies. All three seropositive donors were from the Waco, TX, area, where the estimated seroprevalence rate was 1 in 7700. Two of these three donors reported no risk factors; both were born in the United States and had not traveled to an endemic area. Both had extensive familial histories of cardiac disease and complications. Blood donors seropositive for T. cruzi are present in populations with low to moderate risk, albeit at lower rates. The presence of seropositive blood donors without the usual identifiable risk factors argues against the use of a geographic screening question and also suggests that other routes of transmission, including the congenital route, should be considered in efforts to increase blood safety.
Thalassemia and Hemoglobin E in Southern Thai Blood Donors
Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol
2014-01-01
Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%), heterozygous α-thalassemia 1 (1.7%), heterozygous β-thalassemia without α-thalassemia (0.9%), heterozygous Hb E without α-thalassemia (5.2%), double heterozygotes for Hb E/α-thalassemia 1 (1.7%), homozygous Hb E without α-thalassemia (0.9%), and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%). The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors. PMID:25050123
Laboratory and epidemiologic evaluation of an enzyme immunoassay for antibodies to HTLV-III
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, J.W.; Grindon, A.J.; Feorino, P.M.
1986-07-18
The enzyme immunoassays (EIAs) for antibody to human T-cell lymphotropic virus type III (HTLV-III) were rapidly adopted for screening donated blood and plasma. To evaluate the significance of a positive EIA reaction, test performance was examined in a blood bank screening program. Specimens were tested by EIA, Western blot assay, and HTLV-III/lymphadenopathy-associated virus (LAV) culture. The EIA was positive in 0.25% of 67 190 blood donations. Specimens were categorized and 57.3% had low (weak) reactivity, 12.7% had moderate reactivity, and 30.0% had high reactivity. Highly reactive specimens were strongly associated with a positive Western blot or culture (86.7%) in contrastmore » to moderately and weekly reactive specimens (1.9%). Twenty-five of 29 donors interviewed with a highly reactive EIA had risk factors for HTLV-III/LAV infection. Risk factors were not identified for 74 of 75 interviewed donors with specimens of lower reactivity. The minimum calculated specificity was 99.82%. The use of the HTLV-III EIA has virtually eliminated the use of blood and plasma for HTLV-III/LAV infected donors.« less
Special Blood Donation Procedures
... blood. For example, in the weeks before undergoing elective surgery, a person may donate several units of blood ... rigorous donor screening and testing. In addition, elderly patients may not tolerate donating blood before surgery because they are more likely to have side ...
Rosenberg, Gillian K; Lattimore, Sam; Brailsford, Susan R; Hewitt, Patricia E; Tettmar, Kate I; Kitchen, Alan D; Ijaz, Samreen; Tedder, Richard S
2013-10-01
In 2010 hepatitis B virus (HBV) was the most frequently detected infection in UK blood donation screening, typically found in first-time, male, chronically infected donors born abroad. To date there has been no comprehensive characterization of the virologic profile of these infections. Epidemiologic and serologic data were collected retrospectively for 344 chronically HBV-infected blood donors identified from July 2005 to June 2010. Additional laboratory testing was carried out to determine the HBV genotype, viral load, and prevalence of clinically significant mutations and to detect hepatitis delta virus (HDV) coinfection. Five HBV genotypes (A-E) were found, Genotypes D (45%), A (20%), and E (20%) were the most prevalent. A strong association was seen between genotype and donor ethnicity (p < 0.001) and between genotype and place of residence (p = 0.006). Clinically significant mutations were observed across hepatitis B surface antigen (17%), basal core promoter (25%) and precore (78%) regions. An antiviral resistance profile was identified in one donor. Evidence of HDV coinfection was found in 2% of donors. The data show the diversity of HBV in asymptomatic chronic infections detected in blood donors in England and North Wales and demonstrates the presence of mutations which may impact on disease. The global nature of these infections and the inability to identify chronically infected donors before donation highlights the importance of using screening assays capable of detecting a broad range of genotypes and mutations. Furthermore, the integration of the virologic and demographic data allows us to more accurately construct a profile of our chronically HBV-infected blood donors. © 2012 American Association of Blood Banks.
Goldman, Mindy; Yi, Qi-Long; Ye, Xibiao; Tessier, Lorna; O'Brien, Sheila F
2011-08-01
Few donor criteria are as contentious as the deferral of men who have had sex with men (MSM). We performed an anonymous donor survey to determine attitudes toward current screening and the feasibility and acceptability of adoption of alternate donor criteria for MSM. Donors who had successfully donated to Canadian Blood Services were randomly mailed an anonymous questionnaire several weeks after donation; there were 40,000 donors sampled, evenly split between first-time and repeat donors. The response rate was 45.5%. The vast majority of donors found the current screening questions and clinic environment acceptable. Attention to clinic educational materials was poor. A total of 53% felt that the MSM criteria should be changed; many were supportive of criteria based on specific behaviors rather than a period of abstinence. Gender-neutral questions such as number of sexual partners would result in deferral of large numbers of donors. Many donors would support a change in MSM deferral policy. Implementation of strategies based on donor attention to additional material would be challenging. Universal use of simple gender-neutral questions would result in very high donor loss and are therefore not an acceptable option. The acceptability and feasibility of various screening approaches should be explored further with both donors and advocacy groups. © 2011 American Association of Blood Banks.
Marenzoni, Maria Luisa; Lauzi, Stefania; Miglio, Arianna; Coletti, Mauro; Arbia, Andrea; Paltrinieri, Saverio; Antognoni, Maria Teresa
2017-08-01
Objectives The increased demand for animal blood transfusions creates the need for an adequate number of donors. At the same time, a high level of blood safety must be guaranteed and different guidelines (GLs) deal with this topic. The aim of this study was to evaluate the appropriateness of different GLs in preventing transfusion-transmissible infections (TTI) in Italian feline blood donors. Methods Blood samples were collected from 31 cats enrolled as blood donors by the owners' voluntary choice over a period of approximately 1 year. Possible risk factors for TTI were recorded. Based on Italian, European and American GLs, specific TTI, including haemoplasmas, feline leukaemia virus (FeLV), feline immunodeficiency virus (FIV), Anaplasma phagocytophilum, Ehrlichia species, Bartonella species, Babesia species, Theileria species, Cytauxzoon species, Leishmania donovani sensu lato and feline coronavirus (FCoV) were screened. Rapid antigen and serological tests and biomolecular investigations (PCR) were used. Several PCR protocols for haemoplasma and FeLV DNA were compared. Results The presence of at least one recognised risk factor for TTI was reported in all cats. Results for FIV and FeLV infections were negative using rapid tests, whereas five (16.1%) cats were positive for FCoV antibodies. Four (12.9%) cats were PCR positive for haemoplasma DNA and one (3.2%) for FeLV provirus, the latter being positive only using the most sensitive PCR protocol applied. Other TTI were not detected using PCR. Conclusions and relevance Blood safety increases by combining the recommendations of different GLs. To reduce the risk of TTI, sensitive tests are needed and the choice of the best protocol is a critical step in improving blood safety. The cost and time of the screening procedures may be reduced if appropriate tests are selected. To this end, the GLs should include appropriate recruitment protocols and questionnaire-based risk profiles to identify suitable donors.
Risk factors for Trypanosoma cruzi infection among blood donors in central Brazil.
Martelli, C M; Andrade, A L; Silva, S A; Zicker, F
1992-01-01
Characteristics and possible risk factors associated with Trypanosoma cruzi infection among blood donors were assessed within a routine screening programme in blood banks in an endemic area of Chagas disease. 6,172 voluntary blood donors were interviewed and tested for anti-T. cruzi antibodies by Haemagglutination and Complement Fixation tests in six blood banks in Goiânia-Central Brazil from October 1988 to April 1989. An overall prevalence of 2.3% for T. cruzi infection was obtained, being 3.3% for first-time blood donors and 1.9% for regular ones (p < 0.01). Considering this seropositivity among regular blood donors, selection of candidates relying only on the history of previous donation was found to be inadequate. The risk of infection increased inversely with the degrees of education and monthly income. There was a 9.2 risk of infection (95% CI 3.8-22.6) for those who had lived more than 21 years in an endemic area compared to subjects who had never lived in rural settings, after multivariate analysis. These informations may help to review the criteria of selection of donors in order to improve quality of blood products in endemic areas.
West Nile virus transmission via organ transplantation and blood transfusion - Louisiana, 2008.
2009-11-20
Three years after the introduction and spread of West Nile virus (WNV) in the United States, transmission through blood transfusion and solid organ transplantation was documented in 2002. Within a year, these findings led to nationwide screening of blood donors for WNV. Although screening is extremely sensitive, current methods still do not detect all WNV-infected blood donations, and organ donors are not screened routinely. In October 2008, the Louisiana Department of Health (LDH) was notified of a heart transplant recipient with suspected West Nile neuroinvasive disease (WNND). LDH launched an investigation to confirm the diagnosis and determine whether the organ recipient's infection was derived from the organ donor or blood products the donor received before organ donation. The investigation concluded that two cases of probable transfusion-transmitted WNV resulted from a common blood donor; one infection resulted in WNND via an organ donor, and the other resulted in asymptomatic WNV infection via blood transfusion directly. This investigation also found that criteria used by the blood-screening laboratory to screen the implicated blood donation for WNV were less stringent than criteria used by other blood collection centers in the area. Use of the more stringent screening criteria might have detected the WNV and prevented the blood donation from being used. To increase the likelihood of detecting WNV-positive donations, blood centers should use the most sensitive screening criteria feasible and communicate frequently with nearby blood centers on screening results during times of high WNV activity in their geographic area. In addition, health-care providers should consider WNND as a possible cause of neurologic complications in patients after blood transfusion or organ transplantation.
21 CFR 1271.75 - How do I screen a donor?
Code of Federal Regulations, 2013 CFR
2013-04-01
..., including: (i) Human immunodeficiency virus; (ii) Hepatitis B virus; (iii) Hepatitis C virus; (iv) Human... diseases, including Human T-lymphotropic virus. (c) Donors of reproductive cells or tissue. In addition to... tract. Such screening must include screening for the communicable disease agents listed in paragraphs (c...
21 CFR 1271.75 - How do I screen a donor?
Code of Federal Regulations, 2012 CFR
2012-04-01
..., including: (i) Human immunodeficiency virus; (ii) Hepatitis B virus; (iii) Hepatitis C virus; (iv) Human... diseases, including Human T-lymphotropic virus. (c) Donors of reproductive cells or tissue. In addition to... tract. Such screening must include screening for the communicable disease agents listed in paragraphs (c...
Blood safety implications of donors using HIV pre-exposure prophylaxis.
Seed, C R; Yang, H; Lee, J F
2017-07-01
HIV pre-exposure prophylaxis (PrEP) is the use of one or more antiretroviral medications (in combination) to prevent HIV infection. The most commonly used PrEP medication (Truvada ® , Gilead Sciences, Inc.) acts by inhibiting HIV-1 reverse transcriptase. If someone who is using PrEP unknowingly becomes HIV infected (termed 'PrEP breakthrough infection'), there may be suppressed viral replication resulting in a virus level undetectable by the most sensitive HIV NAT. Failure to seroconvert and seroreversion (loss of previously detectable HIV antibodies) have also both been observed with 2nd, 3rd and 4th generation screening immunoassays, as well as Western blot assays. If such a person was tested in the course of donating blood, the results may therefore be difficult to interpret. The index of suspicion for possible PrEP 'interference' should be highest in the context of concomitant low-level positive or 'greyzone' reactivity on HIV NAT and serological tests, which is an unusual pattern in acutely HIV-infected blood donors. Another possibility is detectable HIV RNA with negative HIV serology (i.e. a potential 'NAT yield' case) but without subsequent HIV seroconversion (or disappearance of HIV RNA). Excluding antiretroviral therapy or PrEP use by the donor in such circumstances would be important. The current rarity of PrEP breakthrough infection indicates that any potential safety risk is likely very small. However, considering the increasing use of PrEP we feel it is prudent for those interpreting HIV donor screening test results to consider the potential for PrEP interference. © 2017 International Society of Blood Transfusion.
Solanki, Archana; Singh, Abhay; Chaudhary, Rajendra
2016-01-01
Enzyme-linked immunosorbent assay (ELISA) used for screening blood donors for transfusion transmitted infections (TTIs) can sometimes fail to detect blood donors who are recently infected or possessing the low strength of pathogen. Estimation of a grey zone in ELISA testing and repeat testing of grey zone samples can further help in reducing the risks of TTI in countries where nucleic acid amplification testing for TTIs is not feasible. Grey zone samples with optical density (OD) lying between cut-off OD and 10% below the cut-off OD (cut-off OD × 0.9) were identified during routine ELISA testing. On performing repeat ELISA testing on grey zone samples in duplicate, the samples showing both OD value below grey zone were marked nonreactive, and samples showing one or both OD value in the grey zone were marked indeterminate. The samples on repeat testing showing one or both OD above cut-off value were marked positive. About 119 samples (77 for hepatitis B virus [HBV], 23 for human immunodeficiency virus [HIV], and 19 for hepatitis C virus [HCV]) were found to be in grey zone. On repeat testing of these samples in duplicate, 70 (58.8%) samples (45 for HBV, 12 for HIV, and 13 for HCV) were found to be reactive. Six (5%) samples (four for HBV, one for HIV, and one for HCV) were found to be indeterminate. Seventy donors initially screened negative, were found out to be potentially infectious on repeat grey zone testing. Thus, estimation of grey zone samples with repeat testing can further enhance the safety of blood transfusion.
Moore, D R; Feurer, I D; Zavala, E Y; Shaffer, D; Karp, S; Hoy, H; Moore, D E
2013-02-01
Most centers utilize phone or written surveys to screen candidates who self-refer to be living kidney donors. To increase efficiency and reduce resource utilization, we developed a web-based application to screen kidney donor candidates. The aim of this study was to evaluate the use of this web-based application. Method and time of referral were tabulated and descriptive statistics summarized demographic characteristics. Time series analyses evaluated use over time. Between January 1, 2011 and March 31, 2012, 1200 candidates self-referred to be living kidney donors at our center. Eight hundred one candidates (67%) completed the web-based survey and 399 (33%) completed a phone survey. Thirty-nine percent of donors accessed the application on nights and weekends. Postimplementation of the web-based application, there was a statistically significant increase (p < 0.001) in the number of self-referrals via the web-based application as opposed to telephone contact. Also, there was a significant increase (p = 0.025) in the total number of self-referrals post-implementation from 61 to 116 per month. An interactive web-based application is an effective strategy for the initial screening of donor candidates. The web-based application increased the ability to interface with donors, process them efficiently and ultimately increased donor self-referral at our center. © Copyright 2012 The American Society of Transplantation and the American Society of Transplant Surgeons.
1985-05-01
minimal. The risk of acquiring syphilis through blood transfusions is so rare that American Association of Blood Bank Standards have dropped the...requirement to test for syphilis , although Federal regulations still require it. Malaria can be effectively screened out by excluding potential donors. 2 9 The...murmur or repair of a congenital defect medical director. Listed below are some does not necessarily disqualify a donor. drugs and medical conditions
Impact of preimplantation genetic screening on donor oocyte-recipient cycles in the United States.
Barad, David H; Darmon, Sarah K; Kushnir, Vitaly A; Albertini, David F; Gleicher, Norbert
2017-11-01
Our objective was to estimate the contribution of preimplantation genetic screening to in vitro fertilization pregnancy outcomes in donor oocyte-recipient cycles. This was a retrospective cross-sectional study of US national data from the Society for Assisted Reproductive Technology Clinic Outcome Reporting System between 2005 and 2013. Society for Assisted Reproductive Technology Clinic Outcome Reporting relies on voluntarily annual reports by more than 90% of US in vitro fertilization centers. We evaluated pregnancy and live birth rates in donor oocyte-recipient cycles after the first embryo transfer with day 5/6 embryos. Statistical models, adjusted for patient and donor ages, number of embryos transferred, race, infertility diagnosis, and cycle year were created to compare live birth rates in 392 preimplantation genetic screening and 20,616 control cycles. Overall, pregnancy and live birth rates were significantly lower in preimplantation genetic screening cycles than in control cycles. Adjusted odds of live birth for preimplantation genetic screening cycles were reduced by 35% (odds ratio, 0.65, 95% confidence interval, 0.53-0.80; P < .001). Preimplantation genetic screening, as practiced in donor oocyte-recipient cycles over the past 9 years, has not been associated with improved odds of live birth or reduction in miscarriage rates. Copyright © 2017 Elsevier Inc. All rights reserved.
Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran
MOHAMMADALI, Fatemeh; POURFATHOLLAH, Aliakbar
2014-01-01
Abstract Background The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. Methods This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Results Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P <0.05) ; percentage of HIV Ag/Ab was higher in donors who had blood group “A” and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Conclusion Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low. PMID:25909065
Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran.
Mohammadali, Fatemeh; Pourfathollah, Aliakbar
2014-07-01
The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P <0.05) ; percentage of HIV Ag/Ab was higher in donors who had blood group "A" and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low.
Screening blood donors for diabetes: analysis of use, accuracy, and cost.
Lenhard, M James; Maser, Raelene E; Kolm, Paul; Healy, Michael J; Seshadri, Prakash
2013-11-01
The objective was to determine if a free, voluntary diabetes screening program as a part of the blood donation process might be cost-effective. During the first 6 months of the program, 26,415 donors were screened using a single random plasma glucose (RPG) level. All donors were asked to eat before donation. Low-, moderate-, and high-risk groups were formed based on RPG levels (<140, 140-200, and >200 mg/dL). Contact with a telephone questionnaire was made with 139 of 178 (78%) of the persons in the high-risk group with 33 new cases of diabetes diagnosed by the donor's physician and 26 donors indicating that they were not diagnosed with diabetes. Sex- and age-matched donors in the low- and moderate-risk groups were contacted and administered the same questionnaire. The three risk groups were similar, except for body mass index (28.1 ± 5.4 kg/m2 vs. 29.9 ± 5.5 kg/m2 vs. 32.7 ± 5.6 kg/m2 , p < 0.001). The discriminative effectiveness of screening was evaluated by the area under the receiver operating characteristics (AROC) curve. The AROC curve was 0.950 (95% confidence interval, 0.920-0.979) for the identification of diabetes. Using a RPG cutoff of 200 mg/dL, sensitivity was 100%, specificity was 82%, and positive predictive value was 56%. Cost analyses showed that the mean cost to screen, per donor, was less than $1. Cost per case identified was estimated to be less than $500 for a RPG cutoff of 200 mg/dL. Screening during the blood donation process appears to be accurate, convenient, and inexpensive. © 2013 American Association of Blood Banks.
Nguyen, Xuan Duc; Dengler, Thomas; Schulz-Linkholt, Monika; Klüter, Harald
2011-02-03
Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti-HNA 3a, n = 3; anti-HNA-1b, n = 1) and GAT (anti-HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.
Long-term in vitro reactivity for HLA antibodies and comparison of detection using serum vs. plasma
Norris, Philip J.; Lee, Jar-How; Carrick, Danielle M.; Gottschall, Jerome L.; Lebedeva, Mila; de Castro, B.R.; Kleinman, Steven H.; Busch, Michael P.
2010-01-01
BACKGROUND HLA antibodies are a possible cause of transfusion-related acute lung injury (TRALI), and fluorescent bead assays are often used for antibody detection. Serum is the manufacturer’s recommended sample, but plasma may be easier to obtain for studies of HLA antibody prevalence and TRALI case investigations. STUDY DESIGN AND METHODS Specimens were obtained from 44 multiparous females positive for HLA antibodies by lymphocytotoxicity testing at least 13 years prior, and from 1,000 contemporary blood donors. Screening tests were performed using a Luminex-based assay. In addition to comparing results obtained with paired plasma and serum samples, the effects of storage at 4 °C for one week and of multiple freeze-thaw cycles were evaluated. RESULTS Of 42 evaluable subjects with HLA antibodies documented >13 years earlier, only 1 showed loss of detectable antibodies, with 39 (93%) positive in the screening assay for class I and 24 (57%) positive in the screening assay for HLA class II antibodies. In 968 evaluable contemporary donors, 291 screened positive for HLA class I and 206 for HLA class II antibodies using a low assay cut-off. Screening test concordance using paired plasma and serum samples was high, particularly for subjects with higher level antibodies. Refrigeration of samples for one week did not significantly affect assay results, while repeated freeze-thaw cycles caused a decrement in signal level. CONCLUSION Serum and plasma samples gave concordant results in the majority of cases, particularly for specimens with higher-level antibodies. High-level HLA antibodies were present in most individuals for over 13 years. PMID:18980615
de Lima, Waleska Mayara Gomes; Esteves, Fabrício Andrade Martins; Torres, Maria do Carmo Morais Rodrigues; Pires, Edna Suely Feitosa
2013-01-01
Background There is difficulty in gathering data on the prevalence of human T-cell lymphotropic virus in blood donors as confirmatory testing is not mandatory in Brazil. This suggests there may be an underreporting of the prevalence. Objective To estimate the prevalence of human T-cell lymphotropic virus types 1 and 2 in donors of a blood bank in Caruaru, Brazil. Methods This was an observational, epidemiological, descriptive, longitudinal and retrospective study with information about the serology of donors of the Caruaru Blood Center, Fundação de Hematologia e Hemoterapia de Pernambuco (Hemope) from May 2006 to December 2010. The data were analyzed using the Excel 2010 computer program (Microsoft Office®). Results Of 61,881 donors, 60 (0.096%) individuals were identified as potential carriers of human T-cell lymphotropic virus types 1 and 2. Of these, 28 (0.045%) were positive and 32 (0.051%) had inconclusive results in the serological screening. Forty-five (0.072%) were retested; 17 were positive (0.027%) and 3 inconclusive (0.005%). After confirmatory tests, 8 were positive (0.013%). Six (75%) of the confirmed cases were women. Conclusion Epidemiological surveys like this are very important in order to create campaigns to attract donors and reduce the costs of laboratory tests. PMID:24106445
Comparison of three noninvasive methods for hemoglobin screening of blood donors.
Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S
2015-02-01
To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.
Molecular genotyping of Indian blood group system antigens in Indian blood donors.
Gogri, Harita; Pitale, Pranali; Madkaikar, Manisha; Kulkarni, Swati
2018-04-11
Haemagglutination has been the gold standard for defining the blood group status. However, these tests depend upon the availability of specific and reliable antisera. Potent antisera for extended phenotyping are very costly, weakly reacting or available in limited stocks and unavailable for some blood group systems like Indian, Dombrock, Coltan, Diego etc. The Indian blood group system consists of two antithetical antigens, In a and In b . The In a /In b polymorphism arises from 252C > G missense mutation in the CD44 gene. This knowledge has allowed the development of molecular methods for genotyping IN alleles. Blood samples were collected from 715 blood donors from Mumbai. DNA was extracted using phenol-chloroform method and genotyping for Indian (In a /IN*01, In b /IN*02) blood group alleles was done by Sequence Specific PCR. Seventeen donors among 715 were heterozygous for In a antigen i.e. In (a+b+). The In a antigen positivity was confirmed serologically, using anti-In a prepared in-house and the genotype-phenotype results were concordant. The frequency of In a (2.37%) was higher than Caucasians and comparable to those reported among Indians of Bombay. This is the first study reporting molecular screening of Indian blood group antigens in Indian population. The frequency of In a and In b antigens was found to be 2.37% and 100% respectively. Red cells of In a positive donors can be used as in-house reagent red cells for screening and identification of corresponding antibodies. Thus, DNA based methods will help in large scale screening of donors to identify rare blood groups, when commercial antisera are unavailable. Copyright © 2018 Elsevier Ltd. All rights reserved.
Seriously ill patients as living unspecified kidney donors: rationale and justification.
Rakké, Yannick S; Zuidema, Willij C; Hilhorst, Medard T; Erdman, Ruud A M; Massey, Emma K; Betjes, Michiel G H; Dor, Frank J M F; IJzermans, Jan N M; Weimar, Willem
2015-01-01
Between 2000 and December 2013, 106 live donor nephrectomies from anonymous living-donors were performed at the Erasmus MC Rotterdam; five of the donors (5.4%) had a life-threatening disease. The aim of the present report is to give the rational and justification for this procedure. All five donors underwent the national standard living-donor screening procedure. Additionally, motivation to donate and psychologic stability were assessed by a psychologist using in-depth interview techniques and a psychologic complaints questionnaire. Post-donor nephrectomy follow-up consisted of standard questionnaires and clinical check-ups. One patient had cerebral and caudal ependymomas, one had severe and progressive emphysema, two had Huntington's disease and one had a grade 2 oligodendroglioma. The psychologic screening revealed genuine motivation, adequate risk perception, and normal sense of reality. No contraindications for donation were found. The five donor nephrectomies made nine kidney transplantations possible. All donors were satisfied with the donation procedure. Three donors died during follow-up (0.6-4.9 years) as a result of their disease. In the absence of apparent additional health risks, medical, and psychologic contraindications, we consider it ethically justified to accept an offer from a cognitively competent patient with a life-threatening disease in view of their self-reported satisfaction during follow-up. Although based on a limited number of patients, we conclude that a stricter psychologic screening for seriously ill donors compared to healthy unspecified anonymous donors to unspecified patients is not necessary.
Performance characteristics of the ARCHITECT anti-HCV assay.
Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter
2005-10-01
The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.
West Nile virus lineage 2 infection in a blood donor from Vienna, Austria, August 2014.
Jungbauer, C; Hourfar, M K; Stiasny, K; Aberle, S W; Cadar, D; Schmidt-Chanasit, J; Mayr, W R
2015-03-01
Eastern Austria is neighbouring regions with ongoing West Nile virus (WNV) transmissions. Three human WNV infections had been diagnosed during the past decade in Austria. The Austrian Red Cross Blood Service (ARC-BS) started a first voluntary screening for WNV in blood donors from Eastern Austria by Nucleic Acid Testing (NAT) in June 2014. This is also the most extensive WNV surveillance programme in humans in Austria so far. In August 2014, one autochthonous WNV infection was detected in a blood donor from Vienna. By now, one in 67,800 whole blood donations was found to be positive for WNV RNA. Copyright © 2015 Elsevier B.V. All rights reserved.
Impact of screening for metabolic syndrome on the evaluation of obese living kidney donors.
Marcusa, Daniel P; Schaubel, Douglas E; Woodside, Kenneth J; Sung, Randall S
2018-01-01
We report our experience with metabolic syndrome screening for obese living kidney donor candidates to mitigate the long-term risk of CKD. We retrospectively reviewed 814 obese (BMI≥30) and 993 nonobese living kidney donor evaluations over 12 years. Using logistic regression, we explored interactions between social/clinical variables and candidate acceptance before and after policy implementation. Obese donor candidate acceptance decreased after metabolic syndrome screening began (56.3%, 46.3%, p < 0.01), while nonobese candidate acceptance remained similar (59.6%, 59.2%, p = 0.59). Adjusting for age, gender, race, BMI, and number of prior evaluations, acceptance of obese candidates decreased significantly more than nonobese (p = 0.025). In candidates without metabolic syndrome, there was no significant change in how age, sex, race, or BMI affected a donor candidate's probability of acceptance. Metabolic syndrome screening is a simple stratification tool for centers with liberal absolute BMI cut-offs to exclude potentially higher-risk obese candidates. Copyright © 2017 Elsevier Inc. All rights reserved.
Zadsar, Maryam; Aghakhani, Arezoo; Banifazl, Mohammad; Kazemimanesh, Monireh; Tabatabaei Yazdi, Seyed Morteza; Mamishi, Setareh; Bavand, Anahita; Sadat Larijani, Mona; Ramezani, Amitis
2018-04-16
Human parvovirus B19 (B19) infection is common among blood donors, and healthy blood donors can transmit virus via transfusion. Due to resistance of B19 to viral inactivation methods, there is a potential concern regarding transfusion safety in blood products. We aimed to determine the seroprevalence, molecular epidemiology, and quantitation of B19 DNA levels in blood donors in Tehran, Iran. A total of 500 blood donors from Blood Transfusion Research Center were studied. ELISA was used for detection of B19 IgG and IgM and nested PCR was carried out for detection of B19 DNA. PCR products were subjected to direct sequencing. B19 viral load was determined by real time PCR. B19 IgG, IgM, and DNA were detected in 27.6, 2.6, and 1.2% of donors respectively. Ten samples (2%) were positive for both antibodies while in four cases (0.8%), B19 IgG and DNA detected simultaneously. One case had B19 IgM, IgG, and viremia concurrently. The titers of B19 DNA in four of six donors were more than 10 6 IU/mL (high level viremia) and all four cases had IgG simultaneously. All B19 isolates categorized in genotype 1A. Our findings indicated that prevalence of B19 DNA in Iranian blood donors was comparable with previous studies throughout the world. High level B19 viremia found in 0.8% of our donors and all viremic donors revealed neutralizing B19 antibody. Therefore implementation of a B19 screening test for each volunteer blood donor does not appear to be necessary but B19 testing for plasma-derived products seems important in Iranian donors. © 2018 Wiley Periodicals, Inc.
1985-01-01
Anti-HTLV III had been detected in 12,689 serum samples collected within August 1985 from 12 Transfusion Centres of Liguria. In the course of the first test, carried out by ELISA using disrupted virions as antigen, 12,666 samples (99.81%) resulted non reactive; 14 (0.1%) belonged to the grey-zone and 9 (0.08%) were clearly reactive. The samples of the last two classes were tested again in the same way and, whenever the cases were suspect as positive, by Western-blot technique. All positive cases, but three, were linked with risk factors such as intravenous drug use or drug addicts partners. Even if the prevalence of blood donors anti-HTLV III positive resulted, on the whole, very low (0.063%), the investigations carried out prove the importance of regular screening of blood units for the prevention of HTLV III infection.
1992-06-26
Many poor people in Indian cities sell their blood to commercial blood banks for up to US$2.50. In fact, so many have done so that there once was a Professional Blood Donors Association. It dissolved though after some members died of AIDS. Health workers believe at least 25% of blood donors in Bombay are HIV positive. Yet a recent study of 70 professional blood donors in Bombay shows only 7 who did not test positive for HIV. Still the government of India does not require blood banks to test for HIV, hepatitis, or other blood borne diseases. In fact, the blood supply is monitored in only 5 cities in India. In India as well as in other Asian countries, physicians advise patients to donate their own blood and have it stored until needed for surgery or to ask for safer blood substitutes, e.g., plasma expanders. In fact, in Singapore, the Autologous Blood Bank charges US$21/year to store units of blood for future use. In Japan, most of the 2008 HIV infected people had received blood plasma from mainly the US before Japan required new sterilization regulations on blood imports. The greatest risk from blood donors comes from those who are paid for their blood because they tend to be poor, to practice unsafe sex, and not to be mindful of their health. Most Asian nations such as Japan and Singapore do screen the blood supply. Further, for almost 20 years, Thailand has checked its blood supply for hepatitis B and syphilis. In 1987, it began testing for AIDS. It does not pay for donated blood. In the Philippines, however, even paying blood donors does not meet the needed blood supply and much of the blood comes from commercial blood banks. Yet the Philippine Red Cross has screened for other diseases since 1960 and for AIDS since 1988.
[Costs of Chagas' disease screening test in blood donors in two Colombian blood banks, 2015].
Alvis, Nelson José; Díaz, Diana Patricia; Castillo, Liliana; Alvis, Nelson Rafael; Bermúdez, María Isabel; Berrío, Olga Maritza; Beltrán, Mauricio; Castañeda-Orjuela, Carlos Andrés
2018-03-15
Transfusion is a mechanism of transmission of Chagas' disease. There are no studies on the costs of the screening test in Colombian blood banks. To estimate the costs of the screening test for Chagas' disease among blood donors in two Colombian blood banks, 2015. We conducted a micro-costing study from the perspective of the health care provider to estimate the cost of Chagas' disease testing in two blood banks, Banco de Sangre de la Cruz Roja, Seccional Bolívar, and Banco de Sangre del Hospital de Yopal, Casanare, taking into account four cost categories: 1) Administrative costs: public services and insurance costs were calculated based on the blood bank area in square meters; 2) capital costs: building and equipment costs that were annualized using a 3% discount rate and a lifespan of 20 years for building and five for equipment; 3) costs of Chagas' disease test materials and reagents adjusted by blood bank production level, and 4) costs of staff in charge of Chagas' disease test processing. The costs of transfusion bagsand immunohematology tests are also reported. The cost of Chagas' disease test in the blood bank of Seccional Bolívar was COP$ 37,804 (USD$ 12), and the blood bag and immunohematology test costs were COP$ 25,941 (USD$ 8.2) and COP$ 6,800 (USD$ 2.2), respectively. In the blood bank of Yopal, Casanare, the costs were COP$ 77,384 (USD$ 24.6), COP$ 30,141 (USD$ 9.6) and COP$ 12,627 (USD$ 4), respectively. Personnel cost accounted for the highest percentage of the total cost for both blood banks (47.5% in Seccional Bolívar, and 55.7% in Yopal, Casanare). Our results are an important input for the planning of services and cost-effectiveness studies for screening tests for Chagas' disease in Colombian blood banks.
Kwenti, Tebit Emmanuel; Njunda, Longdoh Anna; Tsamul, Beltine; Nsagha, Shey Dickson; Assob, Nguedia Jules-Clement; Tufon, Kukwah Anthony; Meriki, Dilonga Henry; Orock, Enow George
2017-08-01
In malaria endemic areas, infected blood donors serve as a source of infection to blood recipients, which may adversely affect their prognosis. This necessitates the proper screening of blood to be used for transfusion in these areas. The purpose of this study was to determine the prevalence of malaria parasitaemia in blood donors in Buea, Cameroon, and to evaluate the performance of a rapid diagnostic test (RDT), a malaria antibody enzyme-linked immunosorbent assay (ELISA), and a Plasmodium lactate dehydrogenase (pLDH) ELISA in the detection of asymptomatic malaria parasitaemia in the target population. In a prospective study conducted between September 2015 and June 2016, 1 240 potential blood donors were enrolled. The donors were screened for malaria parasites using Giemsa microscopy (GM) and a RDT. A sub-sample of 184 samples, comprising 88 positive and 96 negative samples, were selected for the evaluation of the pLDH ELISA and the antibody ELISA. The chi-square test and correlation analysis were performed as part of the statistical analyses. The statistical significance cut-off was set at P < 0.05. The prevalence of malaria parasitaemia in this study was found to be 8.1% (95% CI: 6.6 - 9.7). The prevalence was not observed to be dependent on the age or sex of the participants. The RDT had a sensitivity (88.0%), specificity (99.1%), and negative predictive value (99.0%) higher than the ELISAs. The performance of the pLDH ELISA, which demonstrated the highest positive predictive value (91.6%), was generally comparable to the RDT. The sensitivity was lowest with the antibody ELISA (69.9%), which also demonstrated the highest false positive and false negative rates. The detection threshold for the pLDH (three parasites/μl) was lower compared to the RDT (50 - 60 parasites/μl). Non-significant positive correlations were observed between the parasite density and the pLDH titers and malaria antibody titers. Overall, the RDT and the pLDH ELISA demonstrated a perfectly correlated agreement with GM, meanwhile the antibody ELISA demonstrated a substantially correlated agreement with GM. The pLDH is therefore recommended for mass screening of blood (to detect malaria parasitaemia) for transfusions in the study area. However, where this is not feasible, an RDT will suffice.
Umolu, Patience Idia; Okoror, Lawrence Ehis; Orhue, Philip
2005-03-01
Human Immunodeficiency Virus and Hepatitis B virus are blood borne pathogens that can be transmitted through blood transfusion and could pose a huge problem in areas where mechanisms of ensuring blood safety are suspect. This study became necessary in a population where most of the blood for transfusion is from commercial blood donors. A total of 130 donors comprising 120 commercial donors and 10 voluntary donors were tested for antibodies to human immunodeficiency virus and hepatitis B surface antigen in Benin city using Immunocomb HIV - 1 and 2 Biospot kit and Quimica Clinica Aplicada direct latex agglutination method respectively. Thirteen (10%) samples were HIV seropositive and 7(5.8%) were HBsAg positive. The age bracket 18 - 25years had the highest numbers of donors and also had the highest number of HBsAg positive cases (7.8%) while the age group 29 - 38years had highest number of HIV seropositive cases. High prevalence of HIV antibodies and Hepatitis B surface antigen was found among commercial blood donors. Appropriate and compulsory screening of blood donors using sensitive methods, must be ensured to prevent post transfusion hepatitis and HIV.
Vascellari, Marta; Ravagnan, Silvia; Carminato, Antonio; Cazzin, Stefania; Carli, Erika; Da Rold, Graziana; Lucchese, Laura; Natale, Alda; Otranto, Domenico; Capelli, Gioia
2016-06-29
Many vector-borne pathogens including viruses, bacteria, protozoa and nematodes occur in northeast Italy, representing a potential threat to animal and human populations. Little information is available on the circulation of the above vector-borne pathogens in dogs. This work aims to (i) assess exposure to and circulation of pathogens transmitted to dogs in northeast Italy by ticks, sandflies, and mosquitoes, and (ii) drive blood donor screening at the newly established canine blood bank of the Istituto Zooprofilattico Sperimentale delle Venezie. Blood samples from 150 privately-owned canine candidate blood donors and 338 free-roaming dogs were screened by serology (IFA for Leishmania infantum, Ehrlichia canis, Anaplasma phagocythophilum, Babesia canis, Rickettsia conorii, R. rickettsii), microscopic blood smear examination, and blood filtration for Dirofilaria spp. All candidate donors and seropositive free-roaming dogs were tested by PCR for L. infantum, E. canis, A. phagocythophilum, Babesia/Theileria and Rickettsia spp. The dogs had no clinical signs at the time of sampling. Overall, 40 candidate donors (26.7 %) and 108 free-roaming dogs (32 %) were seroreactive to at least one vector-borne pathogen. Seroprevalence in candidate donors vs free-roaming dogs was: Leishmania infantum 6.7 vs 7.1 %; Anaplasma phagocytophilum 4.7 vs 3.3 %; Babesia canis 1.3 vs 2.7 %; Ehrlichia canis none vs 0.9 %; Rickettsia conorii 16 vs 21.3 % and R. rickettsii 11 vs 14.3 %. Seroreactivity to R. rickettsii, which is not reported in Italy, is likely a cross-reaction with other rickettsiae. Filariae, as Dirofilaria immitis (n = 19) and D. repens (n = 2), were identified in free-roaming dogs only. No significant differences were observed between candidate donors and free-roaming dogs either in the overall seroprevalence of vector-borne pathogens or for each individual pathogen. All PCRs and smears performed on blood were negative. This study demonstrated that dogs are considerably exposed to vector-borne pathogens in northeast Italy. Although the dog owners reported regularly using ectoparasiticides against fleas and ticks, their dogs had similar exposure to vector-borne pathogens as free-roaming dogs. This prompts the need to improve owner education on the use of insecticidal and repellent compounds in order to reduce the risk of arthropod bites and exposure to vector-borne pathogens. Based on the absence of pathogens circulating in the blood of healthy dogs, the risk of transmission of these pathogens by blood transfusion seems to be low, depending also on the sensitivity of the tests used for screening.
Evaluation of prior photorefractive keratectomy in donor tissue.
Terry, M A; Ousley, P J; Rich, L F; Wilson, D J
1999-05-01
To describe a case in which an eye donor had prior bilateral photorefractive keratectomies and to elucidate possible methods of evaluation and screening of donor tissue. Case report. A 62-year-old eye donor was reported to have received radial keratotomy before his death. Further investigation by the eye bank showed a history of photorefractive keratectomy (PRK), not radial keratotomy. The corneas were therefore not used for transplantation, and the eyes were evaluated by slit-lamp examination, photography, corneal topography, and histology. Slit-lamp and photographic examination did not indicate the presence of PRK ablations. Corneal topography mapping with the TMS-1 was relatively ambiguous for identifying PRK flattening, while multiple data formatting of the cornea with the Orbscan resulted in the strongest suggestion of prior PRK. Histologic analysis showed central corneal thinning and loss of Bowman's membrane consistent with PRK. In the absence of a positive donor history for PRK, current methods of screening donor tissue for prior PRK often are insufficient to exclude these corneas from use in transplantation. More refined placido imagery corneal topography or newer technologies such as the Orbscan may allow more sensitive and specific methods of donor tissue screening.
Donor-derived infection--the challenge for transplant safety.
Fishman, Jay A; Grossi, Paolo A
2014-11-01
Organ transplantation, including of the heart, lung, kidney, liver, pancreas, and small bowel, is considered the therapy of choice for end-stage organ failure. Each year, over 70,000 organs are implanted worldwide. One donor may provide multiple organs, as well as corneas and other tissues, for multiple recipients. The degree of risk for transmission of infection carried with grafts, notably of viruses, is largely unknown and, for a specific organ, difficult to assess. The approach to microbiological screening of organ donors varies with national and regional regulations and with the availability and performance of microbiological assays used for potential donors. Transmission of both expected or common, and unexpected infections has been observed in organ transplants, generally recognized after development of clusters of infections among recipients of organs from a common donor. Other than for unusual or catastrophic events, few data exist that define the incidence and manifestations of donor-derived infections or the ideal assays to use in screening to prevent such transmissions. Absolute prevention of the transmission of donor-derived infections in organ transplantation is not possible. However, improvements in screening technologies will enhance the safety of transplantation in the future.
Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda
2015-02-01
Blood establishments routinely perform screening immunoassays to assess safety of the blood components. As with any other screening test, results have an inherent uncertainty. In blood establishments the major concern is the chance of false negatives, due to its possible impact on patients' health. This article briefly reviews GUM and diagnostic accuracy models for screening immunoassays, recommending a scheme to support the screening laboratories' staffs on the selection of a model considering the intended use of the screening results (i.e., post-transfusion safety). The discussion is grounded on a "risk-based thinking", risk being considered from the blood donor selection to the screening immunoassays. A combination of GUM and diagnostic accuracy models to evaluate measurement uncertainty in blood establishments is recommended. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mavenyengwa, Rooyen T; Mukesi, Munyaradzi; Chipare, Israel; Shoombe, Esra
2014-05-05
Transfusion Transmissible Infections (TTIs) such as Human Immunodeficiency Virus (HIV), syphilis, hepatitis B virus (HBV) and hepatitis C virus (HCV) are infections which are common in some communities in Southern Africa. It is important to screen blood donations for these infections. This is a retrospective study which involved reviewing of previous blood donation records for the year 2012 in Namibia. The records were analyzed to determine the prevalence of HIV, syphilis, Hepatitis B and C among blood donations with regard to gender, age and geographical region of the donors. The findings indicated a significantly low prevalence of HIV, syphilis, HBsAg and anti-Hepatitis C among the blood donations. A low infection rate of 1.3% by any of the four tested TTIs was found among the blood donations given by the donor population in Namibia in 2012. The blood donations given by the donor population in Namibia has a low infection rate with the HIV, syphilis, HBsAg and anti-HCV. A strict screening regime must continue to be used as the infections are still present albeit in small numbers.
Bacterial contamination of amniotic membrane in a tissue bank from Iran.
Aghayan, Hamid Reza; Goodarzi, Parisa; Baradaran-Rafii, Alireza; Larijani, Bagher; Moradabadi, Leila; Rahim, Fakher; Arjmand, Babak
2013-09-01
Human Amniotic Membrane (AM) transplantation can promote tissue healing and reduce inflammation, tissue scarring and neovascularization. Homa Peyvand Tamin (HPT) tissue bank has focused on manufacturing human cell and tissue based products including AM. The purpose of this study is to evaluate and identify bacterial contamination of AMs that is produced by HPT for several ophthalmic applications. From July 2006 to April 2011, 122 placentas from cesarean sections were retrieved by HPT after obtaining informed consent from the donors. Besides testing donor's blood sample for viral markers, microbiological evaluation was performed pre and post processing. During tissue processing, decontamination was performed by an antibiotic cocktail including; Gentamicin, Ceftriaxone and Cloxacillin. Of 271 cesarean section AM donors who were screened as potential donors, 122 were accepted for processing and assessed for microbiological contamination. Donors' age were between 21 and 41 years (Mean = 27.61 ± 0.24). More than 92% of mothers were in their first or second gravidity with full term pregnancies. The most prevalent organisms were Staphylococci species (72.53%). After processing, contamination rates markedly decreased by 84.62% (p value = 0.013). According to our results, most of bacterial contaminations were related to donation process and the contamination pattern suggests procurement team as a source. Therefore we recommend that regular training programs should be implemented by tissue banks for procurement staff. These programs should focus on improved donor screening and proper aseptic technique for tissue retrieval. We also suggest that tissue banks should periodically check the rate and types of tissue contaminations. These data help them to find system faults and to update processing methods.
Health Literacy of Living Kidney Donors and Kidney Transplant Recipients
Dageforde, Leigh Anne; Petersen, Alec W.; Feurer, Irene D.; Cavanaugh, Kerri L.; Harms, Kelly A.; Ehrenfeld, Jesse M.; Moore, Derek E.
2015-01-01
Background Health literacy (HL) may be a mediator for known socioeconomic and racial disparities in living kidney donation. Methods We evaluated the associations of patient and demographic characteristics with HL in living kidney donors (LD), living donor kidney transplant recipients (LDR), and deceased donor recipients (DDR) in a single center retrospective review of patients undergoing kidney donation or transplantation from September 2010 to July 2012. HL and demographic data were collected. HL was assessed via the Short Literacy Survey (SLS) comprising three self-reported screening questions scored using the 5-point Likert scale [low (3-8), moderate (9-14), high (15)]. Chi-square and logistic regression were used to test factors associated with lower HL. Results The sample included 360 adults (105 LD, 103 LDR, 152 DDR; 46±14 years; 70% white; 56% male; 14±3 years of education). HL scores were skewed (49% high, 41% moderate, 10% low). The distribution of HL categories differed significantly among groups (p=0.019). After controlling for age, race, gender, education and a race-education interaction term, DDR were more likely to have moderate or low HL than LDR (OR 1.911; 95%CI 1.096, 3.332; p=0.022) Conclusions Overall, living donors had high HL. The distribution of low, moderate and high HL differed significantly between LD, DDR and LDR. DDR had a higher likelihood of having low HL than LDR. Screening kidney transplant candidates and donors for lower HL may identify barriers to living donation. Future interventions addressing HL may be important to increase living donation and reduce disparities. PMID:24573114
Yang, Zhongsi; Xu, Lei; Liu, Li; Feng, Qiuxia; Zhang, Longmu; Ma, Weijuan; Saldanha, John; Wang, Mingmin; Zhao, Lin
2013-10-01
The Roche cobas TaqScreen MPX test was used to evaluate the rate of hepatitis B surface antigen (HBsAg)-negative donations that were hepatitis B virus (HBV) DNA reactive from June 2010 to January 2011 in Qingdao, China. HBsAg-negative samples from 65,800 voluntary blood donors were tested with the cobas TaqScreen MPX test in pools of 6 on the Roche cobas s 201 blood screening platform. Samples positive for HBV DNA and negative for HBsAg were quantitated with the Roche COBAS AmpliPrep/COBAS TaqMan HBV test. In addition, serologic tests for HBsAg, hepatitis B surface antibody, anti-hepatitis B core antigen (anti-HBc), anti-hepatitis B e antigen (anti-HBe), and hepatitis B e antigen (HBe) were done using the Roche electrochemiluminescence immunoassay. A total of 80 nucleic acid amplification technology (NAT) test-reactive pools were identified and 59 pools (74%) resolved to a reactive sample. All samples were HBV DNA reactive and the viral load in each sample was quantitated. The viral loads of the samples ranged from less than 20 to 34,600 IU/mL; 13 samples (22%) had viral loads of more than 20 IU/mL, 27 samples (45.8%) had viral loads of less than 20 IU/mL, and 19 samples (32.2%) had undetectable viral loads. Of the 59 NAT-reactive samples, 40 (67.8%) were anti-HBc positive. Fifteen of the 59 samples could not be confirmed as NAT reactive either by an alternative NAT test or by serology. The HBV NAT yield in blood donors in Qingdao is 0.06% (38/65,800). This study confirmed the value of NAT for interdicting HBV-positive donations and preventing transfusion-transmitted HBV infections. © 2013 American Association of Blood Banks.
Transfusion-transmitted infectious diseases in Argentina, 1995 through 1997.
Schmuñis, G A; Zicker, F; Segura, E L; del Pozo, A E
2000-09-01
Assessment of the safety of the blood supply, the quality of screening procedures, and the risk of transfusion transmission of infectious diseases in any country can be estimated by reviewing the records of blood donations and screening procedures and the prevalence of serologic markers of infectious diseases. Information on blood donors, particularly the number of screened donors, and on the prevalence of serologic markers of infectious diseases was available from Argentina for 1995 through 1997. This information permitted the estimation of the risks and costs of preventing transfusion transmission of infectious diseases within the country during this period. Screening coverage was higher in the private sector. The proportion of donors screened for HIV increased from 84.52 percent in 1995 to 97.97 percent in 1997; in the same period, serologic screening for HbsAg increased from 83.71 percent to 98.48 percent; that for HCV from 69. 92 percent to 97.83 percent; and that for syphilis from 87.94 percent to 98.71 percent. One hundred percent of donors were screened for Trypanosoma cruzi throughout the period. The overall prevalence of HIV per year varied from 2.42 to 3.36 per 1,000 donors; that of HBV, from 5.80 to 9.76 per 1,000; of HCV, from 7.39 to 16.61 per 1,000; and of syphilis, from 5.25 to 7.65 per 1,000. The overall prevalence of antibodies to T. cruzi ranged from 36.53 to 49.20 per 1,000 donors. The overall index of the spread of infectious viral disease through blood transfusion decreased from 47. 74 per 10,000 donations in 1995 to 4.75 per 10,000 in 1997. The ratio of acquired infections to donations improved from 1:209 to 1:2, 102 during the same period. The risk of T. cruzi infection from 1995 through 1997 was, in theory, nil, given the 100-percent screening. The greatest threat to the quality of the blood supply throughout the period studied was HCV. The status of the blood supply in Argentina improved steadily from 1995 to 1997, as shown by the increase in screening coverage.
True HIV seroprevalence in Indian blood donors.
Choudhury, N; Ayagiri, A; Ray, V L
2000-03-01
The National AIDS Control Organization (NACO), the apex body for controlling AIDS in India, projected that HIV seroprevalence would increase from 7/1000 in 1995 to 21.2/1000 in 1997. A high incidence (8.2%) of HIV was observed in blood donors. This study was carried out to find out the true HIV positivity in Indian blood donors. Blood donors from our centre were followed for more than 5 years to determine the true HIV seroprevalence and our result was compared with similar studies from India. Voluntary and relative blood donors who visited the SGPGIMS, Lucknow, since 1993 to June 1998 were included. They were screened for HIV 1/2 by ELISA kits (WHO approved). First-time HIV-positive samples were preserved frozen for further study (stage-I). They were repeated in duplicate and retested with other kits. If found positive, the sample was labelled as ELISA positive (stage-II). ELISA-positive samples were confirmed by Western Blot (WB) at stage-III. A total of 65 288 donors were included and 834 (12.8/1000) were reactive at stage-I. But 1.1/1000 donors were found to be ELISA positive at stage-II, and 0.28/1000 donors were positive by WB at stage-III. The 'seropositivity' rate from the NACO was significantly (P < 0.001) higher than our study. There were five similar Indian studies and seropositivity rate varied from 0.72/1000 (using ELISA and WB) to 5.5/1000 (using ELISA alone). The 'seropositivity' rate from the NACO was significantly (P < 0.001) higher than all these studies. HIV seroprevalence in the present study is lower (P < 0.001) than other Indian figures. The present and other studies confirmed that the projected HIV seroprevalence (82/1000) in Indian blood donors was high. The NACO result was based on one-time ELISA screening reports from zonal blood testing centres which also receive samples from paid donors donating in commercial blood banks. The HIV prevalence of blood donors (and national prevalence) is to be reassessed.
[Serological screening for Trypanosoma cruzi among blood donors in central Brazil].
de Andrade, A L; Martelli, C M; Luquetti, A O; de Oliveira, O S; Almeida e Silva, S; Zicker, F
1992-07-01
The present study compares the results of serological screening for Trypanosoma cruzi infection done at blood banks with results obtained in Chagas' disease studies undertaken by the Reference Laboratory of the Federal University of Goiás (UFG) and evaluates the use of the enzyme-linked immunosorbent assay (ELISA) for this purpose. The study was conducted with data from six of the eight blood banks in the city of Goiânia in central Brazil, an urban area in which this infection is highly endemic. The population studied consisted of 1,513 volunteers who had donated blood for the first time between October 1988 and April 1989. The sample represented 50% of all first-time blood donors during the period. Of these donors, 94% were residents of urban areas, and of these, approximately 26% had migrated from the countryside. Nearly 90% of the blood donations in the city are received at these banks, which normally use the indirect hemagglutination and complement-fixation tests. The samples selected for the study of T. cruzi antibody in first-time blood donors were assayed at the Reference Laboratory of the Federal University of Goiás using the indirect hemagglutination (IH), indirect immunofluorescence (IF), and enzyme-linked immunosorbent assay (ELISA) tests, independently of the serological classification performed by the blood banks. Comparison of the results provided by the latter with the positivity pattern established in the study (IH and IF yielded simultaneous positive results in the Reference Laboratory) revealed a relative sensitivity of 77%, with extremes ranging between 50% and 100%, depending on the blood bank studied.(ABSTRACT TRUNCATED AT 250 WORDS)
Detection of Leishmania infantum by real-time PCR in a canine blood bank.
Tabar, M D; Roura, X; Francino, O; Altet, L; Ruiz de Gopegui, R
2008-07-01
Risk for transmission of Leishmania infantum from blood products has been largely demonstrated in human and veterinary literature. Appropriate screening of canine blood donors is important especially in an endemic area such as Barcelona (Spain). The purpose of this study was to evaluate the presence of L infantum DNA parasites by real-time quantitative PCR in our canine blood bank. Samples from blood products obtained from 92 canine blood donors were assayed for L infantum by means of real-time PCR amplification and quantification. The prevalence of quantitative PCR-positive blood samples among healthy seronegative blood donors was 19.6 per cent. The results of this study show that L infantum infection is common in canine blood donors and their blood products in an endemic area, despite a negative commercial serological screening for infectious diseases. Therefore, screening by PCR should be included in an integrated approach to evaluate L infantum infection among potential blood donors.
Adams, Zachary; Morris, Gail; Campbell, Todd; Mostert, Karen; Dibdin, Nicholas; Fearon, Margaret; Elmoazzen, Heidi; Mercer, Dena; Young, Kimberly; Allan, David
2018-04-01
Zika virus has emerged as a potential threat to the Canadian blood supply system. Stem cell donors within Canadian Blood Services' Cord Blood Bank (CBB) and OneMatch Stem Cell and Marrow Network (OM) now undergo screening measures designed to reduce the risk of Zika virus transmission. The impact these screening measures have on cord blood and unrelated adult stem cell donations is currently unknown. Among 146 donor workups initiated by OM between July 2016 and May 2017, 102 were completed and 44 workups were canceled. There were 17 potential donors (11.6%) with a risk of Zika virus exposure identified by the donor questionnaire (13 completed, 4 canceled workups). None of the workups involved a donor diagnosed with confirmed Zika virus within the past 6 months. Only 1 of the 44 canceled workups (and only 1 of 4 cases with a risk of Zika transmission) was canceled because of the risk of Zika transmission, and a backup donor was selected. Canadian Blood Services' CBB identified 25 of 875 cord blood units (2.9%) from women who donated their infants' cord blood and underwent screening that otherwise met the initial cell number thresholds for banking and had at least 1 risk factor for exposure to Zika virus. No women were diagnosed with Zika virus at any point of their pregnancy. All 25 units were discarded. Unrelated donors at OM have a higher incidence of a risk of exposure to Zika virus compared with cord blood donors. Only rarely did transplant centers cancel donor workups due to potential Zika virus exposure. The impact of screening for Zika virus exposure risk on cord blood banking was minor. Continued vigilance and surveillance is recommended. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Okoroiwu, Henshaw Uchechi; Okafor, Ifeyinwa Maryann; Asemota, Enosakhare Aiyudubie; Okpokam, Dorathy Chioma
2018-05-22
Provision of constant and safe blood has been a public health challenge in Sub-Saharan Africa with high prevalence of transfusion-transmissible infections (TTIs). This study was aimed at determining the trend and seroprevalence of HBV, HCV, syphilis and HIV across the years within study among prospective blood donors at blood bank in University of Calabar Teaching Hospital (UCTH), Calabar, Nigeria. A retrospective analysis of blood donor data from January 2005 to December 2016 was conducted in Blood Bank/Donor Clinic of University of Calabar Teaching Hospital, Calabar, Nigeria. Sera samples were screened for hepatitis B surface antigen (HBsAg), antibodies to hepatitis C virus (HCV), human immunodeficiency virus (HIV) 1 and 2 and Treponema pallidum using commercially available immunochromatic based kits. Out of the 24,979 screened prospective donors in the 2005-2016 study period, 3739 (14.96%) were infected with at least one infective agent. The overall prevalence of HBV, HCV, syphilis and HIV were 4.1, 3.6, 3.1 and 4.2%, respectively. During the period of study, the percentage of all transfusion-transmissible infections declined significantly with remarkable decline in HIV. The study showed male dominated donor pool (98.7%) with higher prevalence (4.2%) of transfusion-transmissible infections than in female donors (0.0%). Commercial donors constituted majority (62.0%) of the donors and as well had the highest prevalence of transfusion-transmissible infections. Majority (62.9%) of the donors were repeat donors. HBV, HCV, syphilis and HIV have remained a big threat to safe blood transfusion in Nigeria and Sub-Saharan Africa at large. Strict adherence to selection criteria and algorithm of donor screening are recommended.
Gómez-Simón, A; Plaza, E M; Torregrosa, J M; Ferrer-Marín, F; Sánchez-Guiu, I; Vicente, V; Lozano, M L; Rivera, J
2014-11-01
Inaccuracy of fingerstick haemoglobin compromises donor's health and losses blood donations. We evaluated the benefit of double haemoglobin screening with HemoCue. Blood donors underwent fingerstick screening by HemoCue and were driven for donation if capillary haemoglobin was within the regulatory range. Those failing were drawn venous blood and donated if their venous haemoglobin determined with HemoCue was acceptable. Of 276 605 donor clinic visits, 10 011 (3·6%) were assessed by two-step haemoglobin screening using HemoCue, because of low (n = 9444) or high (n = 567) capillary haemoglobin. Among these, 2561 (25·6%) were deemed eligible [recovered donations]. The recovery rate was 23·8% and 55·0% among donors presenting with low and high capillary haemoglobin, respectively. In both categories of attempted donations, capillary and venous haemoglobin with HemoCue correlated significantly in recovered donors (R(2) ≈ 0·5-0·7) but not in deferred visits (R(2) < 0·15). Venous haemoglobin with HemoCue and by haematological analyzer significantly correlated in all donations attempts (R(2) ≈ 0·7). Donors presenting with low capillary haemoglobin showed small bias between capillary and venous haemoglobin by HemoCue (-2·4 ± 6·2 g/l), fingerstick haemoglobin and venous haemoglobin with counter (1·3 ± 7·3 g/l), and venous haemoglobin with HemoCue and counter (3·7 ± 3·9 g/l). This bias was slightly greater in donors with high capillary haemoglobin (-7·5 ± 7·8, 13·7 ± 7·5, and 6·2 ± 7·5, respectively). Double haemoglobin screening by HemoCue reached an accuracy of 87·3% for qualifying donors presenting with low fingerstick haemoglobin. Double haemoglobin measurement with HemoCue [fingerstick and venous blood if required] is feasible and allows a significant recovery of blood donations. © 2014 International Society of Blood Transfusion.
Cystic Fibrosis: Prenatal Screening and Diagnosis
... can use in vitro fertilization (IVF) with donor sperm or donor eggs (but the donor should be ... status). You can use IVF with your own sperm and eggs, and then use preimplantation genetic diagnosis ...
Seroprevalence of human parvovirus B19 in healthy blood donors
Kumar, Satish; Gupta, R.M.; Sen, Sourav; Sarkar, R.S.; Philip, J.; Kotwal, Atul; Sumathi, S.H.
2013-01-01
Background Human parvovirus B19 is an emerging transfusion transmitted infection. Although parvovirus B19 infection is connected with severe complications in some recipients, donor screening is not yet mandatory. To reduce the risk of contamination, plasma-pool screening and exclusion of highly viraemic donations are recommended. In this study the prevalence of parvovirus B19 in healthy blood donors was detected by ELISA. Methods A total of 1633 samples were screened for IgM and IgG antibodies against parvovirus B19 by ELISA. The initial 540 samples were screened for both IgM and IgG class antibodies and remaining 1093 samples were screened for only IgM class antibodies by ELISA. Results Net prevalence of IgM antibodies to human parvovirus B19 in our study was 7.53% and prevalence of IgG antibodies was 27.96%. Dual positivity (IgG and IgM) was 2.40%. Conclusion The seroprevalence of human parvovirus B19 among blood donor population in our study is high, and poses an adverse transfusion risk especially in high-risk group of patients who have no detectable antibodies to B19. Studies with large sample size are needed to validate these results. PMID:24600121
Seroprevalence of human parvovirus B19 in healthy blood donors.
Kumar, Satish; Gupta, R M; Sen, Sourav; Sarkar, R S; Philip, J; Kotwal, Atul; Sumathi, S H
2013-07-01
Human parvovirus B19 is an emerging transfusion transmitted infection. Although parvovirus B19 infection is connected with severe complications in some recipients, donor screening is not yet mandatory. To reduce the risk of contamination, plasma-pool screening and exclusion of highly viraemic donations are recommended. In this study the prevalence of parvovirus B19 in healthy blood donors was detected by ELISA. A total of 1633 samples were screened for IgM and IgG antibodies against parvovirus B19 by ELISA. The initial 540 samples were screened for both IgM and IgG class antibodies and remaining 1093 samples were screened for only IgM class antibodies by ELISA. Net prevalence of IgM antibodies to human parvovirus B19 in our study was 7.53% and prevalence of IgG antibodies was 27.96%. Dual positivity (IgG and IgM) was 2.40%. The seroprevalence of human parvovirus B19 among blood donor population in our study is high, and poses an adverse transfusion risk especially in high-risk group of patients who have no detectable antibodies to B19. Studies with large sample size are needed to validate these results.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-24
...] Draft Guidance for Industry: Implementation of Acceptable Abbreviated Donor History Questionnaire and... Acceptable Abbreviated Donor History Questionnaire and Accompanying Materials for Use in Screening Frequent... abbreviated donor history questionnaire and accompanying materials (aDHQ documents), version 1.3 dated August...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-08
...] Guidance for Industry: Implementation of an Acceptable Abbreviated Donor History Questionnaire and... Abbreviated Donor History Questionnaire and Accompanying Materials for Use in Screening Frequent Donors of... history questionnaire and accompanying materials (aDHQ documents), version 1.3 dated December 2012...
Asfaram, Shabnam; Fakhar, Mahdi; Soosaraei, Masoud; Hosseini Teshnizi, Saeed; Mardani, Ahmad; Banimostafavi, Elham Sadat; Ziaei Hezarjaribi, Hajar
2017-10-01
Transmission of Leishmania through transfusion has been reported from various Visceral leishmaniasis (VL) endemic areas of the world. The true burden of Leishmania infection in blood donors remains generally unknown. Thus, the present systematic review attempted to determine the global prevalence of Leishmania infection among blood donors. Data were extracted through five English and five Persian databases during the period from 1997 to 2016. Overall, 16 articles fulfilled the inclusion criteria and were used for data extraction in this systematic review. In total, 13,743 blood donors from different regions of world were examined. The prevalence rate of Leishmania infection according to seropositivity obtained 7% (95%CI: 5%, 8%). The lowest and the highest prevalence were related to Bangladesh 0.25% (95%CI: 0.0%, 1.0%) and Brazil, 16% (95%CI: 12%, 19%). Seroprevalence rate of leishmaniasis among females was more (4.60%) than males. Of 15 studies included in the meta-analysis, the pooled prevalence rate of molecular tests was obtained 2% (95%CI: 1%, 3%) in which Iran and Spain had the lowest and the highest prevalence, 0.05% and 7%, respectively. Our analysis showed that L. infantum was more common than L. donovani as etiological agent of VL among all donors. Our data confirms the presence of asymptomatic carriers of VL in endemic areas and supplies as an attentive to the likelihood of these carriers acting as blood donors. Moreover, we conclude that molecular tests for screening in asymptomatic blood donor provide an accurate estimate of the rate of infection over serological tests. Copyright © 2017 Elsevier Ltd. All rights reserved.
Stem Cell Therapy to Improve Burn Wound Healing
2017-03-01
Aim(s) • Perform Phase 1 Trial of Allogeneic MSCs in Burns • Perform Phase 2 Trial of Allogeneic MSCs in Burns • Collect Tissue Repository for...for safety/dose studies CY15 Goal – Continue Phase 1 and, Start Tissue Repository Continue donors recruitment, screening and Bone Marrow Aspiration...1 Trial and Collect Tissue Repository Continue donors recruitment, screening and Bone Marrow Aspiration as needed. Continue patients screening
Rodríguez, María de Lourdes Garza; Rodriguez, Diana R Rodríguez; Blitvich, Bradley J; López, Miguel A Reyes; Fernández-Salas, Ildefonso; Jimenez, Javier Ramos; Farfán-Ale, José A; Tamez, Rogelio Cazares; Longoria, César Martinez; Aguilar, Maria I Tavitas; Rivas-Estilla, Ana Maria
2010-03-01
A clinical and serological investigation was performed to determine the presence of West Nile virus (WNV) among febrile and encephalitic patients in northern Mexico. In addition, asymptomatic blood donors were serologically assayed for WNV to determine the seroprevalence of WNV in the general population. The study cohort consisted of 1432 individuals (588 febrile patients, 44 encephalitic patients, and 800 asymptomatic blood donors). All subjects were negative for WNV IgM. Sixty subjects were reactive for dengue virus (DENV) IgM (16 blood donors and 44 febrile patients). A subset (n = 425) of individuals was also screened by ELISA for flavivirus IgG. The prevalence of flavivirus IgG in febrile patients, encephalitic patients, and blood donors ranged from 40% to 59%. A subset (n = 147) of sera reactive for flavivirus IgG was further tested by plaque reduction neutralization test. Six individuals with no history of travel during the preceding 12 months were seropositive for WNV. Another 65 individuals were seropositive for DENV1 and 24 were seropositive for DENV2. The high prevalence of dengue antibodies in northern Mexico appears to limit the incidence of WNV infection in this region. Article Summary Line: Antibodies to WNV, DENV-1, and DENV-2 were identified in humans in northern Mexico.
21 CFR 1271.25 - What information is required for establishment registration and HCT/P listing?
Code of Federal Regulations, 2010 CFR
2010-04-01
... OF HEALTH AND HUMAN SERVICES (CONTINUED) REGULATIONS UNDER CERTAIN OTHER ACTS ADMINISTERED BY THE... postal service zip code; (3) The name, address, and title of the reporting official; and (4) A dated... recover, process, store, label, package, distribute, or for which you perform donor screening or testing...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-15
... Transfusion-Transmissible Agents and Blood Cell Antigens in Blood Donations; Public Workshop AGENCY: Food and... Methods to Multiplex Detection of Transfusion- Transmissible Agents and Blood Cell Antigens in Blood... and the use of these tests in blood donor screening and blood cell antigen typing. The public workshop...
Seroprevalence and diagnosis of HIV, HBV, HCV and syphilis infections among blood donors.
Tafesse, Tadesse Bekele; Gebru, Addis Adera; Gobalee, Semgne; Belay, Gosaye Degu; Belew, Molla Teferi; Ataro, Demelash; Ebrahim, Belay Ali; Shebeshi, Getachew Mekonnon; Yimam, Yonas
2017-01-01
Blood transfusion is one of the most important therapeutic options of life-saving intervention for recipients who are in diseased or non-diseased conditions with severe blood loss. However, it is associated with certain risks which can lead to adverse consequences that may cause acute or delayed complications and bring the risk of transfusion-transmissible infections including HIV, Hepatitis B & C and Syphilis. So, there might be a fatal risk instead of life saving. This paper aims to provide a comprehensive and reliable tabulation of available data on seroprevalence and diagnosis of HIV, HBV, HCV and Syphilis infections among blood donors. We searched studies reporting the prevalence rate of HIV, HBV, HCV and Syphilis infections among blood donors that were published between October 2009 and June 2016, using databases of PubMed, Scopus, MEDLINE, Elsevier, ScienceDirect, EBSCO, Google Scholar, EMBASE, and Web of Science with keywords: ``Hepatitis C Virus'', ``Hepatitis B Virus'', ``HIV'', ``Syphilis'', ``Seroprevalence'', and ``blood donor''. The seroprevalence of HBV and HCV was highest in African countries as compared to others continents, predominantly the West African region with a range of 10.0% to 14.96% and 1.5% to 8.69%, respectively, while the overall seropositivity of HIV and syphilis infection show a significant declining pattern through successive years globally, even though relatively higher prevalence rate was observed among older age and those with low level of education. There is a problem during selection, diagnoses and screening process in developing nations primarily due to shortage of sensitive screening test kits, highly qualified human resource and lack of proper standard operating procedures and hence, the safety of blood and blood products are the primary threats in the region. Proper clinical diagnosis and screening method should be applied during blood donation and therefore, all the donated blood should be screened properly for transfusion-transmitted infections.
Noninvasive molecular screening for oral precancer in Fanconi anemia patients.
Smetsers, Stephanie E; Velleuer, Eunike; Dietrich, Ralf; Wu, Thijs; Brink, Arjen; Buijze, Marijke; Deeg, Dorly J H; Soulier, Jean; Leemans, C René; Braakhuis, Boudewijn J M; Brakenhoff, Ruud H
2015-11-01
LOH at chromosome arms 3p, 9p, 11q, and 17p are well-established oncogenetic aberrations in oral precancerous lesions and promising biomarkers to monitor the development of oral cancer. Noninvasive LOH screening of brushed oral cells is a preferable method for precancer detection in patients at increased risk for head and neck squamous cell carcinoma (HNSCC), such as patients with Fanconi anemia. We determined the prevalence of LOH in brushed samples of the oral epithelium of 141 patients with Fanconi anemia and 144 aged subjects, and studied the association between LOH and HNSCC. LOH was present in 14 (9.9%) nontransplanted patients with Fanconi anemia, whereas LOH was not detected in a low-risk group (n = 50, >58 years, nonsmoking/nonalcohol history) and a group with somewhat increased HNSCC risk (n = 94, >58 years, heavy smoking/excessive alcohol use); Fisher exact test, P = 0.023 and P = 0.001, respectively. Most frequent genetic alteration was LOH at 9p. Age was a significant predictor of LOH (OR, 1.13, P = 0.001). Five patients with Fanconi anemia developed HNSCC during the study at a median age of 39.6 years (range, 24.8-53.7). LOH was significantly associated with HNSCC (Fisher exact test, P = 0.000). Unexpectedly, the LOH assay could not be used for transplanted patients with Fanconi anemia because donor DNA in brushed oral epithelium, most likely from donor leukocytes present in the oral cavity, disturbed the analysis. Noninvasive screening using a LOH assay on brushed samples of the oral epithelium has a promising outlook in patients with Fanconi anemia. However, assays need to be adapted in case of stem cell transplantation, because of contaminating donor DNA. ©2015 American Association for Cancer Research.
P. falciparum malaria prevalence among blood donors in Bamako, Mali.
Kouriba, B; Diarra, A B; Douyon, I; Diabaté, D T; Kamissoko, F; Guitteye, H; Baby, M; Guindo, M A; Doumbo, O K
2017-06-01
Malaria parasite is usually transmitted to humans by Anopheles mosquitoes but it can also be transmitted through blood transfusion. Usually malaria transmission is low in African urban settings. In West Africa where the P. falciparum is the most predominant malaria species, there are limited measures to reduce the risk of blood transfusion malaria. The aim of this study was to evaluate the prevalence of P. falciparum malaria carriage among blood donors in the National Blood Center of Bamako, capital city of Mali. The study was conducted using a random sample of 946 blood donors in Bamako, Mali, from January to December 2011. Screening for malaria was performed by thick smear and rapid diagnostic test (RDT). Blood group was typed by Beth-Vincent and Simonin techniques. The frequency of malaria infection was 1.4% by thick smear and 0.8% by the RDT. The pick prevalence of P. falciparum malaria was in rainy season, indicating a probable high seasonal risk of malaria by blood transfusion, in Mali. The prevalence of P. falciparum infection was 2% among donors of group O the majority being in this group. There is a seasonal prevalence of malaria among blood donors in Bamako. A prevention strategy of transfusion malaria based on the combination of selection of blood donors through the medical interview, promoting a voluntary low-risk blood donation and screening all blood bags intended to be transfused to children under 5, pregnant women and immune-compromised patients during transmission season using thick smear will reduce the risk of transfusion malaria in Mali. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Infectious Disease Transmission during Organ and Tissue Transplantation
Kuehnert, Matthew J.; Fishman, Jay A.
2012-01-01
Infectious disease transmission through organ and tissue transplantation has been associated with severe complications in recipients. Determination of donor-derived infectious risk associated with organ and tissue transplantation is challenging and limited by availability and performance characteristics of current donor epidemiologic screening (e.g., questionnaire) and laboratory testing tools. Common methods and standards for evaluating potential donors of organs and tissues are needed to facilitate effective data collection for assessing the risk for infectious disease transmission. Research programs can use advanced microbiological technologies to define infectious risks posed by pathogens that are known to be transplant transmissible and provide insights into transmission potential of emerging infectious diseases for which transmission characteristics are unknown. Key research needs are explored. Stakeholder collaboration for surveillance and research infrastructure is required to enhance transplant safety. PMID:22840823
HEV-positive blood donations represent a relevant infection risk for immunosuppressed recipients.
Westhölter, Dirk; Hiller, Jens; Denzer, Ulrike; Polywka, Susanne; Ayuk, Francis; Rybczynski, Meike; Horvatits, Thomas; Gundlach, Svantje; Blöcker, Johanna; Schulze Zur Wiesch, Julian; Fischer, Nicole; Addo, Marylyn M; Peine, Sven; Göke, Burkhard; Lohse, Ansgar W; Lütgehetmann, Marc; Pischke, Sven
2018-07-01
Routine HEV testing of blood products has recently been implemented in Great Britain and the Netherlands. The relevance of transfusion-transmitted HEV infections is still controversially discussed in Europe. All blood donations at the University Medical Center Hamburg-Eppendorf were prospectively tested for HEV RNA by pooled PCR from October 2016 to May 2017. Reactive samples were individually retested. Additionally, stored samples from previous donations of positive donors were tested to determine the duration of HEV viraemia. HEV RNA-positive donors and a control cohort were asked to answer a questionnaire. Twenty-three out of 18,737 HEV RNA-positive donors were identified (0.12%). Only two of the positive donors (8.7%) presented with elevated aminotransferases at time of donation (alanine aminotransferase: 192 and 101 U/L). The retrospective analysis of all positive donors revealed that four asymptomatic donors had been HEV viraemic for up to three months with the longest duration of HEV viraemia exceeding four months. Despite the HEV-testing efforts, 14 HEV RNA-positive blood products were transfused into 12 immunocompromised and two immunocompetent patients. One recipient of these products developed fatal acute-on-chronic liver failure complicated by Pseudomonas septicemia. The questionnaire revealed that HEV RNA-positive donors significantly more often consumed raw pork meat (12 out of 18; 67%) than controls (89 out of 256; 35%; p = 0.01). In two donors, undercooked pork liver dishes were identified as the source of infection. HEV genotyping was possible in 7 out of 23 of HEV viraemic donors and six out of seven isolates belonged to HEV Genotype 3, Group 2. Prolonged HEV viraemia can be detected at a relatively high rate in Northern German blood donors, leading to transfusion-transmitted HEV infections in several patients with the risk of severe and fatal complications. Eating raw pork tartare represented a relevant risk for the acquisition of HEV infection. The relevance of transfusion-transmitted hepatitis E virus infections has been discussed controversially. Herein, we present the first report on routine hepatitis E virus screening of blood donations at a tertiary care centre in Germany. Hepatitis E viraemia was found at a relatively high rate of 0.12% among blood donors, which represents a relevant transfusion-related risk for vulnerable patient populations. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Feasibility of Using Convalescent Plasma Immunotherapy for MERS-CoV Infection, Saudi Arabia.
Arabi, Yaseen M; Hajeer, Ali H; Luke, Thomas; Raviprakash, Kanakatte; Balkhy, Hanan; Johani, Sameera; Al-Dawood, Abdulaziz; Al-Qahtani, Saad; Al-Omari, Awad; Al-Hameed, Fahad; Hayden, Frederick G; Fowler, Robert; Bouchama, Abderrezak; Shindo, Nahoko; Al-Khairy, Khalid; Carson, Gail; Taha, Yusri; Sadat, Musharaf; Alahmadi, Mashail
2016-09-01
We explored the feasibility of collecting convalescent plasma for passive immunotherapy of Middle East respiratory syndrome coronavirus (MERS-CoV) infection by using ELISA to screen serum samples from 443 potential plasma donors: 196 patients with suspected or laboratory-confirmed MERS-CoV infection, 230 healthcare workers, and 17 household contacts exposed to MERS-CoV. ELISA-reactive samples were further tested by indirect fluorescent antibody and microneutralization assays. Of the 443 tested samples, 12 (2.7%) had a reactive ELISA result, and 9 of the 12 had reactive indirect fluorescent antibody and microneutralization assay titers. Undertaking clinical trials of convalescent plasma for passive immunotherapy of MERS-CoV infection may be feasible, but such trials would be challenging because of the small pool of potential donors with sufficiently high antibody titers. Alternative strategies to identify convalescent plasma donors with adequate antibody titers should be explored, including the sampling of serum from patients with more severe disease and sampling at earlier points during illness.
Transfusion-Transmitted Hepatitis E: NAT Screening of Blood Donations and Infectious Dose.
Dreier, Jens; Knabbe, Cornelius; Vollmer, Tanja
2018-01-01
The risk and importance of transfusion-transmitted hepatitis E virus (TT-HEV) infections by contaminated blood products is currently a controversial discussed topic in transfusion medicine. The infectious dose, in particular, remains an unknown quantity. In the present study, we illuminate and review this aspect seen from the viewpoint of a blood donation service with more than 2 years of experience in routine HEV blood donor screening. We systematically review the actual status of presently known cases of TT-HEV infections and available routine NAT-screening assays. The review of the literature revealed a significant variation regarding the infectious dose causing hepatitis E. We also present the outcome of six cases confronted with HEV-contaminated blood products, identified by routine HEV RNA screening of minipools using the highly sensitive RealStar HEV RT-PCR Kit (95% LOD: 4.7 IU/mL). Finally, the distribution of viral RNA in different blood components [plasma, red blood cell concentrate (RBC), platelet concentrates (PC)] was quantified using the first WHO international standard for HEV RNA for NAT-based assays. None of the six patients receiving an HEV-contaminated blood product from five different donors (donor 1: RBC, donor 2-5: APC) developed an acute hepatitis E infection, most likely due to low viral load in donor plasma (<100 IU/mL). Of note, the distribution of viral RNA in blood components depends on the plasma content of the component; nonetheless, HEV RNA could be detected in RBCs even when low viral plasma loads of 100-1,000 IU/mL are present. Comprehensive retrospective studies of TT-HEV infection offered further insights into the infectivity of HEV RNA-positive blood products. Minipool HEV NAT screening (96 samples) of blood donations should be adequate as a routine screening assay to identify high viremic donors and will cover at least a large part of viremic phases.
Hourfar, Michael K; Jork, Christine; Schottstedt, Volkmar; Weber-Schehl, Marijke; Brixner, Veronika; Busch, Michael P; Geusendam, Geert; Gubbe, Knut; Mahnhardt, Christina; Mayr-Wohlfart, Uschi; Pichl, Lutz; Roth, W Kurt; Schmidt, Michael; Seifried, Erhard; Wright, David J
2008-08-01
The risk of transfusion-transmitted human immunodeficiency virus-1 (HIV-1), hepatitis C virus (HCV), and hepatitis B virus (HBV) infections is predominantly attributable to donations given during the early stage of infection when diagnostic tests may fail. In 1997, nucleic acid amplification technique (NAT)-testing was introduced at the German Red Cross (GRC) blood donor services to reduce this diagnostic window period (WP). A total of 31,524,571 blood donations collected from 1997 through 2005 were screened by minipool NAT, predominantly with pool sizes of 96 donations. These donations cover approximately 80 percent of all the blood collected in Germany during that period. Based on these data, the WP risk in the GRC blood donor population was estimated by using a state-of-the-art mathematic model. During the observation period, 23 HCV, 7 HIV-1, and 43 HBV NAT-only-positive donations were detected. On the basis of these data and estimated pre-NAT infectious WPs, the residual risk per unit transfused was estimated at 1 in 10.88 million for HCV (95% confidence interval [CI], 7.51-19.72 million), 1 in 4.30 million for HIV-1 (95% CI, 2.39-21.37 million), and 1 in 360,000 for HBV (95% CI, 0.19-3.36 million). Based on observed cases of breakthrough infections, the risk of transfusion-related infections may be even lower. The risk of a blood recipient becoming infected with HCV, HIV-1, or HBV has reached an extremely low level. Introduction of individual donation testing for HCV and HIV-1 would have a marginal effect on interception of WP donations.
Trends of T. cruzi infection based on data from blood bank screening.
Zicker, F; Martelli, C M; de Andrade, A L; Almeida e Silva, S
1990-01-01
Between October 1988 and April 1989 a cross-sectional survey was carried out in six out of eight blood banks of Goiánia, Central Brazil. Subjects attending for first-time blood donation in the mornings of the study period (n = 1358) were interviewed and screened for T. cruzi infection as a part of a major study among blood donors. Tests to anti-T. cruzi antibodies were performed, simultaneously, by indirect hemagglutination test (IHA) and complement fixation test (CFT). A subject was considered seropositive when any one of the two tests showed a positive result. Information on age, sex, place of birth, migration and socio-economic level was recorded. Results from this survey were compared with seroprevalence rates obtained in previous studies in an attempt to analyse trend of T. cruzi infection in an endemic urban area. The overall seroprevalence of T. cruzi infection among first-time donors was found to be 3.5% (95% confidence interval 2.5%-4.5%). The seroprevalence rate increased with age up to 45 years and then decreased. Migrants from rural areas had higher seroprevalence rates than subjects from urban counties (1.8%-16.2% vs. 0%-3.6%). A four fold decrease in prevalence rates was observed when these rates were compared with those of fifteen years ago. Two possible hypotheses to explain this difference were suggested: 1. a cohort effect related with the decrease of transmission in rural areas and/or 2. a differential proportion of people of rural origin among blood donors between the two periods. The potential usefulness of blood banks as a source of epidemiological information to monitor trends of T. cruzi infection in an urban adult population was stressed.
The infectious disease blood safety risk of Australian hemochromatosis donations.
Hoad, Veronica; Bentley, Peter; Bell, Barbara; Pathak, Praveen; Chan, Hiu Tat; Keller, Anthony
2016-12-01
It has been suggested that blood donors with hereditary hemochromatosis may pose an increased infectious disease risk and adversely affect recipient outcomes. This study compares the infectious disease risk of whole blood (WB) donors enrolled as therapeutic (T) donors to voluntary WB donors to evaluate the safety of blood products provided by the T donors. This was a retrospective cohort study of all WB donations at the Australian Red Cross Blood Service who donated between January 1, 2011, and December 31, 2013, comparing a yearly mean of 11,789 T donors with 107,773 total donations and a yearly mean of 468,889 voluntary WB donors with 2,584,705 total donations. We compared postdonation notification of infectious illnesses, bacterial contamination screening results, and positive tests for blood borne viruses in T and WB donors. Rates of transfusion-transmissible infections in donations destined for component manufacture were significantly lower in therapeutic donations compared to voluntary donations (8.4 vs. 21.6 per 100,000 donations). Bacterial contamination (43.0 vs. 45.9 per 100,000 donations) and postdonation illness reporting (136.2 vs. 110.8 per 100,000 donations) were similar in both cohorts. The Australian therapeutic venisection program enables T donors to provide a safe and acceptable source of donated WB that has a low infectious disease risk profile. © 2016 AABB.
2014-01-01
Background Transfusion Transmissible Infections (TTIs) such as Human Immunodeficiency Virus (HIV), syphilis, hepatitis B virus (HBV) and hepatitis C virus (HCV) are infections which are common in some communities in Southern Africa. It is important to screen blood donations for these infections. Methods This is a retrospective study which involved reviewing of previous blood donation records for the year 2012 in Namibia. The records were analyzed to determine the prevalence of HIV, syphilis, Hepatitis B and C among blood donations with regard to gender, age and geographical region of the donors. Results The findings indicated a significantly low prevalence of HIV, syphilis, HBsAg and anti-Hepatitis C among the blood donations. A low infection rate of 1.3% by any of the four tested TTIs was found among the blood donations given by the donor population in Namibia in 2012. Conclusion The blood donations given by the donor population in Namibia has a low infection rate with the HIV, syphilis, HBsAg and anti-HCV. A strict screening regime must continue to be used as the infections are still present albeit in small numbers. PMID:24884633
Cost-effectiveness of the screening of blood donations for hepatitis E virus in the Netherlands.
de Vos, Anneke S; Janssen, Mart P; Zaaijer, Hans L; Hogema, Boris M
2017-02-01
The incidence of hepatitis E virus (HEV) has increased substantially in Europe recently, thereby threatening blood safety. A cost-effectiveness analysis for HEV screening of blood donations in the Netherlands was performed. A simulation model was developed to mimic the process of donation, infections in the donor population, donation testing, and transmission to transfusion recipients. The variability of viral loads among donors was modeled using observed loads. The number of (incurable) chronic HEV infections among organ and stem cell transplant patients and the costs avoided by implementing blood screening were estimated. HEV screening of whole blood donations in pools of 24 would prevent 4.52 of the 4.94 transfusion-associated chronic HEV infections expected annually, at approximately €310,000 per prevented chronic case. Per case not curable by ribavirin prevention, costs are approximately 10 times higher. Selective screening, if logistically feasible, could reduce screening costs by 85%. Sensitivity analyses show that uncertainty in the HEV transmissibility and the frequency of HEV clearing greatly impact the estimated cost-effectiveness. Of all HEV infections nationwide one in 700 is estimated to be due to blood transfusion, while for chronic infections this is one in 3.5. Despite uncertainties in our estimates, preventing HEV transmission by screening of blood donations appears not excessively expensive compared to other blood-screening measures in the Netherlands. However, the impact on HEV disease burden may be relatively small as only a minority of all HEV cases is transmitted by blood transfusion. © 2017 AABB.
Mapako, Tonderai; Mvere, David A; Chitiyo, McLeod E; Rusakaniko, Simbarashe; Postma, Maarten J; van Hulst, Marinus
2013-10-01
National Blood Service Zimbabwe human immunodeficiency virus (HIV) risk management strategy includes screening and discarding of first-time donations, which are collected in blood packs without an anticoagulant (dry pack). To evaluate the impact of discarding first-time donations on blood safety the HIV prevalence, incidence, and residual risk in first-time and repeat donations (wet packs) were compared. Donor data from 2002 to 2010 were retrieved from a centralized national electronic donor database and retrospectively analyzed. Chi-square test was used to compare HIV prevalence with relative risk (RR), and the RR point estimates and 95% confidence interval (CI) are reported. Trend analysis was done using Cochran-Armitage trend test. HIV residual risk estimates were determined using published residual risk estimation models. Over the 9 years the overall HIV prevalence estimates are 1.29% (n = 116,058) and 0.42% (n = 434,695) for first-time and repeat donations, respectively. The overall RR was 3.1 (95% CI, 2.9-3.3; p < 0.0001). The overall mean residual transmission risk of HIV window phase donations in first-time was 1:7384 (range, 1:11,308-1:5356) and in repeat donors it was 1:5496 (range, 1:9943-1:3347). The significantly high HIV prevalence estimates recorded in first-time over repeat donations is indicative of the effectiveness of the HIV risk management strategy. However, comparable residual transmission risk estimates in first-time and repeat donors point to the need to further review the risk management strategies. Given the potential wastage of valuable resources, future studies should focus on the cost-effectiveness and utility of screening and discarding first-time donations. © 2013 American Association of Blood Banks.
Bouike, Y; Imoto, S; Mabuchi, O; Kokubunji, A; Kai, S; Okada, M; Taniguchi, R; Momose, S; Uchida, S; Nishio, H
2011-04-01
To clarify transfusion incidence of hepatitis B virus (HBV) infected blood negative for mini pool-nucleic acid amplification testing (MP-NAT). Japanese Red Cross (JRC) blood centres screen donated blood to avoid contamination with HBV. However, a low copy number of HBV may be overlooked. In Hyogo-Prefecture, JRC blood centres screened 787 695 donations for HBV from April 2005 to March 2009. Of these, 685 844 were donations from the repeat donors. To detect the donors with HBV, serological tests, MP-NAT and/or individual donation (ID)-NAT were performed. To detect the recipients with transfusion-transmitted HBV infection (TTHBI), serological analysis and/or ID-NAT were performed. In this study, 265 of the 685 844 repeat donations were serologically and/or MP-NAT positive for HBV. Their repository samples from the previous donation were examined in a look-back study; 13 of the 265 repository samples proved ID-NAT positive. Twelve recipients were transfused with HBV-infected blood components derived from 10 of the 13 HBV-infected donors. Only 1 of the 12 recipients was identified as TTHBI case. Seven of the 12 recipients escaped from our follow-up study and 4 recipients were negative for HBV during the observation period. On the basis of the look-back study among the repeat donors in Hyogo-Prefecture, Japan, donations with HBV-infected blood negative for MP-NAT occurred with a frequency of 13 in 685 844 donations (∼1/53 000 donations). However, more than half of the recipients transfused with HBV-infected blood negative for MP-NAT could not be followed up. It is necessary to establish a more cautious follow-up system. © 2010 The Authors. Transfusion Medicine © 2010 British Blood Transfusion Society.
Cahill, Sean; Wang, Timothy
2017-01-01
In recent years, countries around the world have revised their blood donation policies regarding gay and bisexual men, and other men who have sex with men (MSM). The United States lifted the lifetime ban on MSM from donating blood in 2015, replacing it with a 1 year deferral policy allowing MSM to donate if they abstain from sex for 12 months. Other countries followed suit, while Italy and Spain have implemented deferral policies based on individual risk assessments regardless of sexual orientation. If Israel were to adopt a one year deferral policy for MSM, as recommended by Drs. Ginsberg et al. in this issue, the increase in risk to the blood supply would be minimal. Moving to a 1 year deferral policy would be an important step forward, but it could still be seen as stigmatizing to gay and bisexual men. We recommend that Israel consider a deferral policy based on individual risk assessment rather than a blanket deferral for all MSM. MSM can engage in low- and high-risk sexual behaviors. Those who consistently engage in low-risk behaviors, such as using condoms and pre-exposure prophylaxis consistently, pose little risk to the blood supply. An individual risk assessment policy would screen potential donors of all sexual orientations for low-, medium-, and high-risk behaviors. Potential donors identified as high-risk, such as injection drug users, would justifiably be subject to lengthy or permanent bans. MSM who engage in low-risk sexual behaviors would be allowed to donate without deferral. Medium-risk donors, such as men who have recently had unprotected anal sex with another man, would be subject to a deferral period of 1 month, which is in line with the window period of current HIV screening technology. Most fourth generation HIV tests can detect HIV within a month, and the nucleic acid test used to screen blood can detect HIV in just 9-11 days. Various studies have developed questions for ascertaining HIV risk among MSM which could be used in blood donor questionnaires. Using tablets or other technology that enhances privacy to conduct the blood donor questionnaire could improve collection of this sensitive information.
Söhngen, D; Wienen, S; Siebler, M; Boogen, C; Scheid, C; Schulz, A; Kobbe, G; Diehl, V; Heyll, A
1998-12-01
Experimental evidence suggests a stimulatory effect of recombinant human granulocyte colony-stimulating factor (rhG-CSF) on both platelets and coagulation. RhG-CSF is increasingly used to stimulate healthy volunteer donors for blood stem cell mobilization. We therefore assessed 25 healthy donors receiving rhG-CSF for changes in in vitro bleeding test (IVBT), coagulation parameters and cerebral microembolism by transcranial Doppler (TCD) ultrasound. A significant shortening of IVBT was found on day 4 of rhG-CSF administration together with increased levels of fibrinogen and factor VIII and reduced activities of protein C and protein S. Although these changes are quite small it is possible that they may lead to a hypercoagulable state especially in donors with other risk factors for thromboembolism. However, TCD examination failed to detect any signs of microembolism. We therefore conclude that rhG-CSF leads to significant changes in coagulation parameters, but has no effect on TCD detectable microembolism as a stroke risk factor. However donors receiving rhG-CSF should be examined carefully to detect pre-existing changes in the coagulation system and we would like to suggest a routine thrombophilia screen.
O'Hare, Esther Marie; Wood, Angela; Fiske, Elizabeth
2013-01-01
Forms of human milk banking and donation have been present for more than a century worldwide, but, since 1985, the Human Milk Banking Association of North America (HM BANA) has established guidelines to make the use of donor's breast milk safe and the second best form of feeding to maternal breast milk for a neonatal intensive care unit (NICU) infant. The Indiana Mother's Human Milk Bank provides an extensive and meticulous process of selecting breast milk donors. The process begins with a phone interview with a potential donor and includes the review of the donor's medical records, blood laboratory screening, medication and dietary intake, as well as consent from the donor's pediatrician. The milk bank follows steps of collecting, storing, and receiving the breast milk in accordance with the guidelines of the HM BANA. Pasteurization is the method used to ensure the proper heating and cooling of breast milk. Despite the rigorous pasteurization method, the donor's breast milk will not lose most of the important beneficial components needed for sick or ill NICU infants. Every batch of pasteurized breast milk will be cultured for any possible contamination and shipped to NICUs after it has been cleared by laboratory testing.
Yamada, Naoya; Sanada, Yukihiro; Katano, Takumi; Tashiro, Masahisa; Hirata, Yuta; Okada, Noriki; Ihara, Yoshiyuki; Miki, Atsushi; Sasanuma, Hideki; Urahashi, Taizen; Sakuma, Yasunaru; Mizuta, Koichi
2016-11-28
This is the first report of living donor liver transplantation (LDLT) for congenital hepatic fibrosis (CHF) using a mother's graft with von Meyenburg complex. A 6-year-old girl with CHF, who suffered from recurrent gastrointestinal bleeding, was referred to our hospital for liver transplantation. Her 38-year-old mother was investigated as a living donor and multiple biliary hamartoma were seen on her computed tomography and magnetic resonance imaging scan. The mother's liver function tests were normal and she did not have any organ abnormality, including polycystic kidney disease. LDLT using the left lateral segment (LLS) graft from the donor was performed. The donor LLS graft weighed 250 g; the graft recipient weight ratio was 1.19%. The operation and post-operative course of the donor were uneventful and she was discharged on post-operative day (POD) 8. The graft liver function was good, and the recipient was discharged on POD 31. LDLT using a graft with von Meyenburg complex is safe and useful. Long-term follow-up is needed with respect to graft liver function and screening malignant tumors.
Obtaining corneal tissue for keratoplasty.
Navarro Martínez-Cantullera, A; Calatayud Pinuaga, M
2016-10-01
Cornea transplant is the most common tissue transplant in the world. In Spain, tissue donation activities depend upon transplant coordinator activities and the well-known Spanish model for organ and tissue donation. Tissue donor detection system and tissue donor evaluation is performed mainly by transplant coordinators using the Spanish model on donation. The evaluation of a potential tissue donor from detection until recovery is based on an exhaustive review of the medical and social history, physical examination, family interview to determine will of the deceased, and a laboratory screening test. Corneal acceptance criteria for transplantation have a wider spectrum than other tissues, as donors with active malignancies and infections are accepted for kearatoplasty in most tissue banks. Corneal evaluation during the whole process is performed to ensure the safety of the donor and the recipient, as well as an effective transplant. Last step before processing, corneal recovery, must be performed under standard operating procedures and in a correct environment. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
San Martín, Héctor; Balanda, Monserrat; Vergara, Nicolás; Valenzuela, María Antonieta; Cartier, Luis; Ayala, Salvador; Ramírez, Eugenio
2016-06-01
Infection with human T-lymphotropic virus type 1/2 (HTLV-1/2) is a major health problem. HTLV-1/2 infection is endemic in Chile but representative donor prevalence data are lacking. Data on all blood donors in a large network of Chilean blood centers were examined during 2011-2013. Screening of HTLV-1/2 antibodies were measured by enzyme immunoassay (EIA) at all blood banks. Blood samples with anticoagulants from initially reactive blood donors were analyzed by serological confirmation tests (immunofluorescence or recombinant immunoblot) at the HTLV National Reference Laboratory of the Public Health Institute of Chile. Additionally, detection of HTLV-1 and HTLV-2 provirus in peripheral blood mononuclear cells (PBMCs) was performed in all blood donors as confirmatory test. Prevalence rates were calculated. Among 694,016 donors, 706 were seropositive for HTLV-1 (prevalence, 1.02 cases per 1,000; 95% confidence interval [CI], 0.94-1.09), and 97 were seropositive for HTLV-2 (prevalence, 0.14 cases per 1,000; 95%CI, 0.11-0.17). Prevalence of HTLV-1 differed considerably by region, from 0.51 to 1.69 per 1,000. Prevalence of HTLV-2 was similar across the country (0.12-0.16). HTLV-1 prevalence was associated with female sex, older age, and residence in the north of Chile. HTVL-2 prevalence was associated with older age. The HTLV-1 prevalence among Chilean blood donors was relatively high and could be reduced by improving donor recruitment and selection in high prevalence areas. Blood center data may contribute to surveillance for HTLV-1 and HTLV-2 infections. © 2015 Wiley Periodicals, Inc.
Trotter, Patrick B; Summers, Dominic M; Robb, Matthew; Hulme, William; Ushiro-Lumb, Ines; Watson, Christopher J E; Neuberger, James; Bradley, J Andrew
2017-07-01
Deceased organ donors are routinely screened for behaviors that increase the risk of transmissible blood-borne viral (BBV) infection, but the impact of this information on organ donation and transplant outcome is not well documented. Our aim was to establish the impact of such behavior on organ donation and utilization, as well transplant recipient outcomes. We identified all UK deceased organ donors from 2003 to 2015 with a disclosed history of increased risk behavior (IRB) including intravenous drug use (IVDU), imprisonment and increased risk sexual behavior. Of 17 262 potential donors, 659 (3.8%) had IRB for BBV and 285 (1.7%) were seropositive for BBV, of whom half had a history of IRB (mostly IVDU [78.5%]). Of actual donors with IRB, 393 were seronegative for viral markers at time of donation. A history of recent IVDU was associated with fewer potential donors proceeding to become actual organ donors (64% vs 75%, P = 0.007). Donors with IRB provided 1091 organs for transplantation (624 kidneys and 467 other organs). Transplant outcome was similar in recipients of organs from donors with and without IRB. There were 3 cases of unexpected hepatitis C virus transmission, all from an active IVDU donor who was hepatitis C virus seronegative at time of donation, but was found to be viremic on retrospective testing. Donors with a history of IRB provide a valuable source of organs for transplantation with good transplant outcomes and there is scope for increasing the use of organs from such donors.
Polomeni, A; Bompoint, C; Gomez, A; Brissot, E; Ruggeri, A; Belhocine, R; Mohty, M
2017-11-01
Haematopoietic stem cell transplantation-coordinating nurses (HSCT-CNs) play an important role in informing related donors (RDs) and in organising human leucocyte antigen (HLA) tests, pre-donation workup and stem cells collection. Our pilot study aimed to explore French HSCT-CNs' perceptions of RD care issues. Twenty-nine French HSCT adult units were sent a questionnaire on the subject of donation procedures, HSCT-CNs' data and their professional experience of related donation issues. Twenty-two HSCT-CNs returned a completed questionnaire, and 90% of HSCT units were involved to some degree in both patient and donor care. Responses indicated that the provision of information to potential donors prior to HLA tests was insufficient, while donors were given a medical consultation only during the pre-donation workup. Questions were raised about the consent and voluntary status of RDs. None of the HSCT teams organised a post-donation consultation, while 57% provided follow-up by phone or via a questionnaire. Our results draw attention to the conflict of interest experienced by HSCT-CNs when caring simultaneously for patients and donors. The specific psychosocial difficulties associated with becoming an RD are also highlighted. French HSCT-CNs' perceptions of related donation reveal many ethical and clinical problems that have yet to be fully explored. Data on this topic remain scarce, and our pilot study may contribute to the current debate on the organisation of RD care. © 2016 John Wiley & Sons Ltd.
2005 Donor Eligibility Requirements: Unintended Consequences for Stem Cell Development.
Couture, Larry A; Carpenter, Melissa K
2015-10-01
Several human embryonic stem cell (hESC)-derived cell therapeutics have entered clinical testing and more are in various stages of preclinical development. The U.S. Food and Drug Administration (FDA) regulates these products under existing regulations and has stated that these products do not constitute a new class of biologic. However, as human tissue, hESCs are subject to regulations that were developed before hESCs were first described. The regulations have not been revised since 2005, well before the first hESC-derived product entered clinical studies. The current regulations require donors of hESCs to be tested in the same manner as donors of tissues intended for transplantation. However, because hESC-derived cell products are more than minimally manipulated, they are also subject to the same end-of-production release testing as most other biologic agents. In effect, this makes hESC products subject to redundant testing. No other biologic is subject to a similar testing requirement. Furthermore, the regulations that require donor testing are specifically applicable to hESC cells harvested from donors after a date in 2005. It is unclear which regulations cover hESCs harvested before 2005. Ambiguity in the guidelines and redundant testing requirements have unintentionally created a burdensome regulatory paradigm for these products and reluctance on the part of developers to invest in these promising therapeutics. We propose a simple solution that would address FDA safety concerns, eliminate regulatory uncertainty and risk, and provide flexibility for the FDA in the regulation of hESC-derived cell therapies. Regulatory ambiguity concerning donor eligibility screening and testing requirements for human embryonic stem cell lines, in particular those lines created before 2005, are causing significant concern for drug developers. Technically, most of these lines fail to meet eligibility under U.S. Food and Drug Administration (FDA) rules for product licensure, and many developers are unaware that FDA approval to begin trials under an exemption is not an assurance that the FDA will grant licensure of the product. This Perspective outlines the ambiguity and the problem it has caused and proposes a workable solution. The intent is to generate stakeholder and FDA discussion on this issue. ©AlphaMed Press.
Ellingson, Katherine D.; Sapiano, Mathew R.P.; Haass, Kathryn A.; Savinkina, Alexandra A.; Baker, Misha L.; Henry, Richard A.; Berger, James J.; Kuehnert, Matthew J.; Basavaraju, Sridhar V.
2017-01-01
BACKGROUND In August 2016, the Food and Drug Administration advised US blood centers to screen all whole blood and apheresis donations for Zika virus (ZIKV) with an individual-donor nucleic acid test (ID-NAT) or to use approved pathogen reduction technology (PRT). The cost of implementing this guidance nationally has not been assessed. STUDY DESIGN AND METHODS Scenarios were constructed to characterize approaches to ZIKV screening, including universal ID-NAT, risk-based seasonal allowance of minipool (MP) NAT by state, and universal MP-NAT. Data from the 2015 National Blood Collection and Utilization Survey (NBCUS) were used to characterize the number of donations nationally and by state. For each scenario, the estimated cost per donor ($3–$9 for MP-NAT, $7–$13 for ID-NAT) was multiplied by the estimated number of relevant donations from the NBCUS. Cost of PRT was calculated by multiplying the cost per unit ($50–$125) by the number of units approved for PRT. Prediction intervals for costs were generated using Monte Carlo simulation methods. RESULTS Screening all donations in the 50 states and DC for ZIKV by ID-NAT would cost $137 million (95% confidence interval [CI], $109–$167) annually. Allowing seasonal MP-NAT in states with lower ZIKV risk could reduce NAT screening costs by 18% to 25%. Application of PRT to all platelet (PLT) and plasma units would cost $213 million (95% CI, $156–$304). CONCLUSION Universal ID-NAT screening for ZIKV will cost US blood centers more than $100 million annually. The high cost of PRT for apheresis PLTs and plasma could be mitigated if, once validated, testing for transfusion transmissible pathogens could be eliminated. PMID:28591470
Identification of anti-Lea by platelet complement fixation.
Ando, B; Ibayashi, H
1986-01-01
Two anti-Lea sera which were able to detect Lea antigen on platelets were identified in a screening for anti-platelet antibodies by means of a platelet complement fixation test. These two antisera hemolyzed erythrocytes without enzyme treatment. The anti-Lea activity could be completely absorbed by red cells, platelets and lymphocytes of Le(a+b-) donors but not by cells from Le(a-b+) or Le(a-b-) donors. The antibody activity against red cells was eliminated by treatment of the antisera with dithiothreitol, thereby suggesting that the activity resided in the IgM class of immunoglobulins. As the anti-Lea was more reactive at 37 degrees C than at room temperature against both red cells and platelets, we suggest that transfusion of platelets of Lea-negative donors should be considered for patients with this type of anti-Lea.
Lucky, Tarana T A; Seed, Clive R; Waller, Daniel; Lee, June F; McDonald, Ann; Wand, Handan; Wroth, Stephen; Shuttleworth, Glen; Keller, Anthony J; Pink, Joanne; Wilson, David P
2014-07-01
Using a predonation screening questionnaire, potential blood donors are screened for medical or behavioral factors associated with an increased risk for transfusion-transmissible infection. After disclosure of these risks, potential donors are deferred from donating. Understanding the degree of failure to disclose full and truthful information (termed noncompliance) is important to determine and minimize residual risk. This study estimates the prevalence of, and likely reasons for, noncompliance among Australian donors with the deferrals for injecting drug use, sex with an injecting drug user, male-to-male sex, sex worker activity or contact, and sex with a partner from a high-HIV-prevalence country. An anonymous, online survey of a nationally representative sample of Australian blood donors was conducted. Prevalence of noncompliance with deferrable risk categories was estimated. Factors associated with noncompliance were determined using unadjusted and adjusted odds ratios. Of 98,044 invited donors, 30,790 donors completed the survey. The estimated prevalence of overall noncompliance (i.e., to at least one screening question) was 1.65% (95% confidence interval CI, 1.51%-1.8%). Noncompliance with individual deferrals ranged from 0.05% (sex work) to 0.54% (sex with an injecting drug user). The prevalences of the disclosed exclusionary risk behaviors were three to 14 times lower than their estimated prevalence in the general population. The prevalence of noncompliance is relatively low but our estimate is likely to be a lower bound. The selected high-risk behaviors were substantially less common in blood donors compared to the general population suggesting that self-deferral is effective. Nevertheless, a focus on further minimization should improve the blood safety. © 2014 AABB.
Keller-Stanislawski, B; Reil, A; Günay, S; Funk, M B
2010-01-01
In an observational cohort study (2006-2007) the Paul-Ehrlich-Institut collected epidemiological data to investigate the frequency and causes of TRALI. Diagnosis of TRALI was confirmed according to criteria of the European Haemovigilance Network. Subsequent testing of white blood cell antibodies (WBC-Ab) against HLA or human neutrophil alloantigens was performed. Of a total of 187 reported TRALI cases, 44 could be confirmed consisting of 35 cases of antibody-mediated TRALI and nine cases of non-immune-mediated TRALI. Eight of 44 affected patients (18%) had a fatal outcome, seven cases with WBC-Ab positive plasma donors and one case with red blood cell donors. WBC antibodies were found in one male and 39 female donors. In 34 female donors, a history of pregnancy was confirmed. WBC-Ab positive donors presented four HLA class I antibodies, 15 HLA class II antibodies, 13 HLA class I and class II antibodies, one HNA-2a, and seven HNA-3a antibodies. WBC antibodies matching with recipient antigens were found exclusively in 28 female donors; 26 FFP donors, one platelet donor and one red blood cell donor. Reporting frequency of immune-mediated TRALI was 1:66,000 for fresh frozen plasma, 1:2.86 million for red blood cell concentrates and 1:420,000 for platelet concentrates. Reporting frequency of TRALI-related fatalities was 1:285,000 for FFP. Haemovigilance data show the significance of female donors with a history of pregnancy for the development of antibody-mediated TRALI. Manufacturing of FFP from male plasma and female donor screening for WBC-Ab could represent preventive measures.
Spotted fever group--Rickettsiae in the Tyrols: evidence by seroepidemiology and PCR.
Sonnleitner, S T; Simeoni, J; Lang, S; Dobler, G; Speck, S; Zelger, R; Schennach, H; Lass-Flörl, C; Walder, G
2013-06-01
The aim of our study was to assess the occurrence of Rickettsia in the inner-alpine valleys of the Eastern Alps and to determine the amount of seroreaction among the local human population. Ticks were investigated by PCR and the percentage of seropositives was determined among local blood donors by an in-house immunofluorescence assay. The local cut-off titre for screening of IgG was set at 1 : 128 with a well-characterised low-risk collective according to WHO-guidelines. Positive sera were confirmed by independent re-testing. Rickettsia is present in ticks north and south of the continental divide. Of 259 ticks investigated, 12.4% are positive for Rickettsia. Of over 1200 blood donors tested so far, 7.7% bear IgG at a titre of 1 : 128 or higher against R. helvetica. R. helvetica is present in the study area, causes immunoreaction among local residents and is associated with anamnestic erythema. Furthermore, screening with a second Spotted Fever Group Rickettsia indicates that significant parts of the Tyrolean population are exposed to a Rickettsia other than R. helvetica. © 2012 Blackwell Verlag GmbH.
Maple, Peter A C; Beard, Stuart; Parry, Ruth P; Brown, Kevin E
2013-10-01
Human parvovirus 4 (ParV4), a newly described member of the family Parvoviridae, like B19V, has been found in pooled plasma preparations. The extent, and significance, of ParV4 exposure in UK blood donors remain to be determined and reliable detection of ParV4 immunoglobulin (Ig)G, using validated methods, is needed. With ParV4 virus-like particles a ParV4 IgG time-resolved fluorescence immunoassay (TRFIA) was developed. There is no gold standard or reference assay for measuring ParV4 IgG and the utility of the TRFIA was first examined using a panel of sera from people who inject drugs (PWIDS)--a high-prevalence population for ParV4 infection. Western blotting was used to confirm the specificity of TRFIA-reactive sera. Two cohorts of UK blood donor sera comprising 452 sera collected in 1999 and 156 sera collected in 2009 were tested for ParV4 IgG. Additional testing for B19V IgG, hepatitis C virus antibodies (anti-HCV), and ParV4 DNA was also undertaken. The rate of ParV4 IgG seroprevalence in PWIDS was 20.7% and ParV4 IgG was positively associated with the presence of anti-HCV with 68.4% ParV4 IgG-positive sera testing anti-HCV-positive versus 17.1% ParV4 IgG-negative sera. Overall seropositivity for ParV4 IgG, in 608 UK blood donors was 4.76%. The ParV4 IgG seropositivity for sera collected in 1999 was 5.08%, compared to 3.84% for sera collected in 2009. No ParV4 IgG-positive blood donor sera had detectable ParV4 DNA. ParV4 IgG has been found in UK blood donors and this finding needs further investigation. © 2013 American Association of Blood Banks.
Anti-P1: the most common unexpected antibodies in northeastern-Thais.
Romphruk, A V; Wanhagij, C; Akahat, J; Tantanapornkul, P; Anuphan, T; Pattayaso, P; Puapairoj, C
1999-08-01
The prevalence of unexpected antibodies in the Northeastern-Thai population was studied. Sera were collected from 25,673 blood donors including 18,209 males and 7,464 females. The sera were screened for unexpected antibodies by saline and enzyme techniques. The sera which gave a positive antibody screening test were identified for specificity of antibody. The result demonstrated that 3,928 from 25,673 samples (15.30%) were positive for the antibody screening test and only 3,883 samples could be identified for specificity of antibody. The most common unexpected antibodies were anti-P1, anti-lewis and anti-P1 + anti-lewis with the frequency of 70.8, 18.6 and 10.1 per cent, respectively. The prevalence of anti-P1 in this study was higher than that reported in Central Thailand and Southeast Asia which may due to the high prevalence of liver fluke infection in the Northeastern-Thai population.
Mortensen, E; Hellinger, W; Keller, C; Cowan, L S; Shaw, T; Hwang, S; Pegues, D; Ahmedov, S; Salfinger, M; Bower, W A
2014-02-01
Solid organ transplant recipients have a higher frequency of tuberculosis (TB) than the general population, with mortality rates of approximately 30%. Although donor-derived TB is reported to account for <5% of TB in solid organ transplants, the source of Mycobacterium tuberculosis infection is infrequently determined. We report 3 new cases of pulmonary TB in lung transplant recipients attributed to donor infection, and review the 12 previously reported cases to assess whether cases could have been prevented and whether any cases that might occur in the future could be detected and investigated more quickly. Specifically, we evaluate whether opportunities existed to determine TB risk on the basis of routine donor history, to expedite diagnosis through routine mycobacterial smears and cultures of respiratory specimens early post transplant, and to utilize molecular tools to investigate infection sources epidemiologically. On review, donor TB risk was present among 7 cases. Routine smears and cultures diagnosed 4 asymptomatic cases. Genotyping was used to support epidemiologic findings in 6 cases. Validated screening protocols, including microbiological testing and newer technologies (e.g., interferon-gamma release assays) to identify unrecognized M. tuberculosis infection in deceased donors, are warranted. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ehteram, Hassan; Ramezani, Amitis; Eslamifar, Ali; Sofian, Masoomeh; Banifazl, Mohammad; Ghassemi, Shahin; Aghakhani, Arezoo; Mashayekhi, Parisa
2013-01-01
Background and Objectives Hepatitis E virus (HEV) is a major public health concern in developing countries. HEV transmission occurs primarily by the fecal-oral route. It has also been reported that blood donors are potentially able to cause transfusion-associated hepatitis E in endemic areas. This study aimed to determine the seroprevalence of HEV infection among volunteer blood donors in Central province of Iran in 2012. Material and Methods A total of 530 consecutive blood donor samples collected from Blood Transfusion Organization, Central Province of Iran. All samples were tested for the presence of IgG Hepatitis E antibody (anti-HEV) using enzyme-linked immunosorbent assay (ELISA). Results From 530 blood donors, 91.9% were male and 8.1% were female. Overall, anti-HEV was found in 76 of 530 samples (14.3%). There was no significant difference in HEV seropositivity between the subjects regarding gender and area of residence (urban vs. rural). Anti-HEV was distributed among all age groups. Although people aged 31-50 years had the highest prevalence, but there was no statistical difference between the age groups. Conclusion This study shows a relatively high prevalence of anti-HEV in the blood donors of Central province of Iran. More investigations are needed to assess the potential benefit of adding HEV screening of blood products to the current blood donor selection criteria. PMID:23825737
Parvovirus B19: What Is the Relevance in Transfusion Medicine?
Juhl, David; Hennig, Holger
2018-01-01
Parvovirus B19 (B19V) has been discovered in 1975. The association with a disease was unclear in the first time after the discovery of B19V, but meanwhile, the usually droplet transmitted B19V is known as the infectious agent of the “fifth disease,” a rather harmless children’s illness. But B19V infects erythrocyte progenitor cells and thus, acute B19V infection in patients with a high erythrocyte turnover may lead to a life-threatening aplastic crisis, and acutely infected pregnant women can transmit B19V to their unborn child, resulting in a hydrops fetalis and fetal death. However, in many adults, B19V infection goes unnoticed and thus many blood donors donate blood despite the infection. The B19V infection does not impair the blood cell counts in healthy blood donors, but after the acute infection with extremely high DNA concentrations exceeding 1010 IU B19V DNA/ml plasma is resolved, B19V DNA persists in the plasma of blood donors at low levels for several years. That way, many consecutive donations that contain B19V DNA can be taken from a single donor, but the majority of blood products from donors with detectable B19V DNA seem not to be infectious for the recipients from several reasons: first, many recipients had undergone a B19V infection in the past and have formed protective antibodies. Second, B19V DNA concentration in the blood product is often too low to infect the recipient. Third, after the acute infection, the presence of B19V DNA in the donor is accompanied by presumably neutralizing antibodies which are protective also for the recipient of his blood products. Thus, transfusion-transmitted (TT-) B19V infections are very rarely reported. Moreover, in most blood donors, B19V DNA concentration is below 1,000 IU/ml plasma, and no TT-B19V infections have been found by such low-viremic donations. Cutoff for an assay for B19V DNA blood donor screening should, therefore, be approximately 1,000 IU/ml plasma, if a general screening of blood donors for single donation blood components is considered at all: for the overwhelming majority of transfusion recipients, B19V infection is not relevant as well as for the blood donors. B19V DNA screening of vulnerable patients after transfusion seems to be a more reasonable approach than general blood donor screening. PMID:29450198
Ferreira, S C; de Almeida-Neto, C; Nishiya, A S; Oliveira, C D L; Ferreira, J E; Alencar, C S; Levi, J E; Salles, N A; Mendrone, A; Sabino, E C
2014-06-01
To identify the demographic characteristics, risk factors and motivations for donating among blood donors with reactive serologic tests for syphilis. Post-donation interviews with syphilis seropositive blood donors improve recruitment and screening strategies. This case-control study compares 75 Venereal Disease Research Laboratory (VDRL) > 8, EIA+ (enzyme immunoassay) and FTA-ABS+ (fluorescent treponemal antibody); 80 VDRL-, EIA+ and FTA-ABS+; and 34 VDRL- and EIA- donors between 2004 and 2009. Donors were assessed by their demographic characteristics, sexual behaviour, history of alcohol and illicit drugs use, and motivations to donate. Donors with VDRL > 8 were more likely to be divorced [AOR = 12·53; 95% confidence interval (CI) 1·30-120·81], to have had more than six sexual partners (AOR=7·1; 95% CI 1·12-44·62) and to report male-male-sex in the past 12 months (AOR=8·18; 95% CI 1·78-37·60). Donors with VDRL-, EIA+ and FTA-ABS+ were less likely to be female (AOR=0·26; 95% CI 0·07-0·96), more likely to be older (AOR=10·2; 95% CI 2·45-42·58 ≥ 39 and <60 years old) and to have had more than six sexual partners in the past 12 months (AOR = 8·37; 95% CI 1·49-46·91). There was no significant difference among groups regarding illicit drugs use; 30·7% (VDRL > 8) and 12·5% (VDRL-, EIA+ and FTA-ABS+) of donors reported that they had been at risk for HIV infection (P = 0·004). One-third of donors came to the blood bank to help a friend or a relative who needed blood. Although donors exposed to syphilis reported and recognised some high risk behaviour, most were motivated by direct appeal to donate blood. Monitoring the risk profile of blood donors can benefit public health and improve blood safety. © 2014 The Authors. Transfusion Medicine © 2014 British Blood Transfusion Society.
Anaemia, iron deficiency and iron deficiency anaemia among blood donors in Port Harcourt, Nigeria.
Jeremiah, Zaccheaus Awortu; Koate, Baribefe Banavule
2010-04-01
There is paucity of information on the effect of blood donation on iron stores in Port Harcourt, Nigeria. The present study was, therefore, designed to assess, using a combination of haemoglobin and iron status parameters, the development of anaemia and prevalence of iron deficiency anaemia in this area of Nigeria. Three hundred and forty-eight unselected consecutive whole blood donors, comprising 96 regular donors, 156 relatives of patients and 96 voluntary donors, constituted the study population. Three haematological parameters (haemoglobin, packed cell volume, and mean cell haemoglobin concentration) and four biochemical iron parameters (serum ferritin, serum iron, total iron binding capacity and transferrin saturation) were assessed using standard colorimetric and ELISA techniques. The prevalence of anaemia alone (haemoglobin <11.0 g/dL) was 13.7%. The prevalence of isolated iron deficiency (serum ferritin <12 ng/mL) was 20.6% while that of iron-deficiency anaemia (haemoglobin <11.0 g/dL + serum ferritin <12.0 ng/mL) was 12.0%. Among the three categories of the donors, the regular donors were found to be most adversely affected as shown by the reduction in mean values of both haematological and biochemical iron parameters. Interestingly, anaemia, iron deficiency and iron-deficiency anaemia were present almost exclusively among regular blood donors, all of whom were over 35 years old. Anaemia, iron deficiency and iron-deficiency anaemia are highly prevalent among blood donors in Port Harcourt, Nigeria. It will be necessary to review the screening tests for the selection of blood donors and also include serum ferritin measurement for the routine assessment of blood donors, especially among regular blood donors.
Challenges in hepatitis B detection among blood donors.
Allain, Jean-Pierre; Cox, Laura
2011-11-01
The availability of hepatitis B virus (HBV) nucleic acid testing (NAT) for donor blood screening led to its implementation in low prevalence and high prevalence countries. Genomic detection was a substantial addition to HBV surface protein (HBsAg) screening by detecting window period infections and 'occult' HBV infections (OBIs), characterized by undetectable HBsAg, low viral load and presence of serological markers (anti-HBc and/or anti-HBs). OBIs are the result of multiple, poorly understood mechanisms including incomplete immune control mutations of the HBsAg antigenic determinants; abnormal expression of S gene; and inhibition of genome transcription. Infectivity for the recipient is high for window period blood and relatively low for OBIs. The number of cases identified by NAT ranges between 1 : 1000 and 1 : 50 000, depending on epidemiology and assay sensitivity whether NAT is implemented in individual donations or pools of samples. OBI donors are generally older than 45 years except in Africa, carry very low viral load (median 11-25 IU/ml) and have normal alanine transaminase levels. Cases carrying anti-HBc alone are more infectious than those with low level of anti-HBs. Evidence of HBsAg escape mutants that are undetected by commercial assays has been published. Inhibition of HBsAg mRNA production and export are potential mechanisms of OBI occurrence. HBV blood safety is improved by NAT for HBV DNA when applied to individual donations. Until the sensitivity of NAT is improved, both this method and HBsAg screening are needed to eliminate potentially infectious blood donations. Occult HBV characterization clarifies new facets of HBV natural history.
Carrell, Douglas T; Cartmill, Deborah; Jones, Kirtly P; Hatasaka, Harry H; Peterson, C Matthew
2002-07-01
To evaluate variability in donor semen quality between seven commercial donor sperm banks, within sperm banks, and between intracervical insemination and intrauterine insemination. Prospective, randomized, blind evaluation of commercially available donor semen samples. An academic andrology laboratory. Seventy-five cryopreserved donor semen samples were evaluated. Samples were coded, then blindly evaluated for semen quality. Standard semen quality parameters, including concentration, motility parameters, World Health Organization criteria morphology, and strict criteria morphology. Significant differences were observed between donor semen banks for most semen quality parameters analyzed in intracervical insemination samples. In general, the greatest variability observed between banks was in percentage progressive sperm motility (range, 8.8 +/- 5.8 to 42.4 +/- 5.5) and normal sperm morphology (strict criteria; range, 10.1 +/- 3.3 to 26.6 +/- 4.7). Coefficients of variation within sperm banks were generally high. These data demonstrate the variability of donor semen quality provided by commercial sperm banks, both between banks and within a given bank. No relationship was observed between the size or type of sperm bank and the degree of variability. The data demonstrate the lack of uniformity in the criteria used to screen potential semen donors and emphasize the need for more stringent screening criteria and strict quality control in processing samples.
Hepatitis B, HIV, and Syphilis Seroprevalence in Pregnant Women and Blood Donors in Cameroon.
Dionne-Odom, Jodie; Mbah, Rahel; Rembert, Nicole J; Tancho, Samuel; Halle-Ekane, Gregory E; Enah, Comfort; Welty, Thomas K; Tih, Pius M; Tita, Alan T N
2016-01-01
Objectives. We estimated seroprevalence and correlates of selected infections in pregnant women and blood donors in a resource-limited setting. Methods. We performed a cross-sectional analysis of laboratory seroprevalence data from pregnant women and voluntary blood donors from facilities in Cameroon in 2014. Rapid tests were performed to detect hepatitis B surface antigen, syphilis treponemal antibodies, and HIV-1/2 antibodies. Blood donations were also tested for hepatitis C and malaria. Results. The seroprevalence rates and ranges among 7069 pregnant women were hepatitis B 4.4% (1.1-9.6%), HIV 6% (3.0-10.2%), and syphilis 1.7% (1.3-3.8%) with significant variability among the sites. Correlates of infection in pregnancy in adjusted regression models included urban residence for hepatitis B (aOR 2.9, CI 1.6-5.4) and HIV (aOR 3.5, CI 1.9-6.7). Blood donor seroprevalence rates and ranges were hepatitis B 6.8% (5.0-8.8%), HIV 2.2% (1.4-2.8%), syphilis 4% (3.3-4.5%), malaria 1.9%, and hepatitis C 1.7% (0.5-2.5%). Conclusions. Hepatitis B, HIV, and syphilis infections are common among pregnant women and blood donors in Cameroon with higher rates in urban areas. Future interventions to reduce vertical transmission should include universal screening for these infections early in pregnancy and provision of effective prevention tools including the birth dose of univalent hepatitis B vaccine.
Pharmacophore modeling and virtual screening to identify potential RET kinase inhibitors.
Shih, Kuei-Chung; Shiau, Chung-Wai; Chen, Ting-Shou; Ko, Ching-Huai; Lin, Chih-Lung; Lin, Chun-Yuan; Hwang, Chrong-Shiong; Tang, Chuan-Yi; Chen, Wan-Ru; Huang, Jui-Wen
2011-08-01
Chemical features based 3D pharmacophore model for REarranged during Transfection (RET) tyrosine kinase were developed by using a training set of 26 structurally diverse known RET inhibitors. The best pharmacophore hypothesis, which identified inhibitors with an associated correlation coefficient of 0.90 between their experimental and estimated anti-RET values, contained one hydrogen-bond acceptor, one hydrogen-bond donor, one hydrophobic, and one ring aromatic features. The model was further validated by a testing set, Fischer's randomization test, and goodness of hit (GH) test. We applied this pharmacophore model to screen NCI database for potential RET inhibitors. The hits were docked to RET with GOLD and CDOCKER after filtering by Lipinski's rules. Ultimately, 24 molecules were selected as potential RET inhibitors for further investigation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Rios, Jorge A; Schlumpf, Karen S; Kakaiya, Ram M; Triulzi, Darrell J; Roback, John D; Kleinman, Steve H; Murphy, Edward L; Gottschall, Jerome L; Carey, Patricia M
2011-06-01
Transfusion-related acute lung injury (TRALI) mitigation strategies include the deferral of female donors from apheresis platelet (PLT) donations and the distribution of plasma for transfusion from male donors only. We studied the implications of these policies in terms of component loss at six blood centers in the United States. We collected data from allogeneic blood donors making whole blood and blood component donations during calendar years 2006 through 2008. We analyzed the distribution of donations in terms of the sex, transfusion and pregnancy histories, and blood type. A TRALI mitigation policy that would not allow plasma from female whole blood donors to be prepared into transfusable plasma components would result in nearly a 50% reduction in the units of whole blood available for plasma manufacturing and would decrease the number of type AB plasma units that could be made from whole blood donations by the same amount. Deferral of all female apheresis PLT donors, all female apheresis PLT donors with histories of prior pregnancies, or all female apheresis PLT donors with histories of prior pregnancies and positive screening test results for antibodies to human leukocyte antigens (HLAs) will result in a loss of 37.1, 22.5, and 5.4% of all apheresis PLT donations, respectively. A TRALI mitigation policy that only defers female apheresis PLT donors with previous pregnancies and HLAs would result in an approximately 5% decrease in the inventory of apheresis PLTs, but would eliminate a large proportion of components that are associated with TRALI. © 2010 American Association of Blood Banks.
Haiden, Nadja; Ziegler, Ekhard E
2016-01-01
Human milk banks play an essential role by providing human milk to infants who would otherwise not be able to receive human milk. The largest group of recipients are premature infants who derive very substantial benefits from it. Human milk protects premature infants from necrotizing enterocolitis and from sepsis, two devastating medical conditions. Milk banks collect, screen, store, process, and distribute human milk. Donating women usually nurse their own infants and have a milk supply that exceeds their own infants' needs. Donor women are carefully selected and are screened for HIV-1, HIV-2, human T-cell leukemia virus 1 and 2, hepatitis B, hepatitis C, and syphilis. In the milk bank, handling, storing, processing, pooling, and bacterial screening follow standardized algorithms. Heat treatment of human milk diminishes anti-infective properties, cellular components, growth factors, and nutrients. However, the beneficial effects of donor milk remain significant and donor milk is still highly preferable in comparison to formula. © 2017 S. Karger AG, Basel.
Reexamination of human T cell lymphotropic virus (HTLV-I/II) prevalence.
Zucker-Franklin, D; Pancake, B A; Marmor, M; Legler, P M
1997-06-10
In the United States, blood donors are being screened for infection with human T cell lymphotropic viruses I and II (HTLV-I/II) by serologic means, which detect antibodies to the structural proteins of these viruses. Because patients with mycosis fungoides (MF) usually do not have such antibodies even though their cells harbor HTLV-I Tax and/or pol proviral sequences, it was questioned whether the prevalence of HTLV infection among healthy blood donors may also be underestimated by current means of testing. To examine this possibility, a study on specimens of relatives of mycosis fungoides patients (MFR) was begun. In addition, to collect data more expeditiously, a cohort of former injection drug users (IDUs) was tested by routine serologic methods, as well as by PCR/Southern blot analysis for Tax, pol, and gag proviral sequences and Western blot analysis for antibodies to the Tax gene product. To date, 6/8 MFRs and 42/81 (51.8%) of HIV-negative IDUs proved to be positive for HTLV, whereas routine serology identified none of the MFR and only 18/81 (22.2%) of the IDUs. Among the latter test subjects, the incidence of HTLV-I also proved to be 10 times higher than expected. Therefore, it is likely that among healthy blood donors infection with HTLV-I/II is more prevalent than is currently assumed. Since Tax is the transforming sequence of HTLV-I/II, testing for Tax sequences and antibodies to its gene product may be desirable in blood transfusion and tissue donor facilities.
Reexamination of human T cell lymphotropic virus (HTLV-I/II) prevalence
Zucker-Franklin, Dorothea; Pancake, Bette A.; Marmor, Michael; Legler, Patricia M.
1997-01-01
In the United States, blood donors are being screened for infection with human T cell lymphotropic viruses I and II (HTLV-I/II) by serologic means, which detect antibodies to the structural proteins of these viruses. Because patients with mycosis fungoides (MF) usually do not have such antibodies even though their cells harbor HTLV-I Tax and/or pol proviral sequences, it was questioned whether the prevalence of HTLV infection among healthy blood donors may also be underestimated by current means of testing. To examine this possibility, a study on specimens of relatives of mycosis fungoides patients (MFR) was begun. In addition, to collect data more expeditiously, a cohort of former injection drug users (IDUs) was tested by routine serologic methods, as well as by PCR/Southern blot analysis for Tax, pol, and gag proviral sequences and Western blot analysis for antibodies to the Tax gene product. To date, 6/8 MFRs and 42/81 (51.8%) of HIV-negative IDUs proved to be positive for HTLV, whereas routine serology identified none of the MFR and only 18/81 (22.2%) of the IDUs. Among the latter test subjects, the incidence of HTLV-I also proved to be 10 times higher than expected. Therefore, it is likely that among healthy blood donors infection with HTLV-I/II is more prevalent than is currently assumed. Since Tax is the transforming sequence of HTLV-I/II, testing for Tax sequences and antibodies to its gene product may be desirable in blood transfusion and tissue donor facilities. PMID:9177230
Wei, Cheong Tar; Al-Hassan, Faisal Muti; Naim, Norris; Knight, Aishah; Joshi, Sanmukh R
2013-01-01
Diego blood group antigen, Di(a), is very rare among Caucasians and Blacks, but relatively common among the South American Indians and Asians of Mongolian origin. The antibody to Di(a) is clinically significant to cause hemolytic disease in a new-born or hemolytic transfusion reaction. This study was designed to determine the prevalence of Di(a) antigen among the blood donors from the three major ethnic groups in Klang Valley of Malaysia as well as to find an incidence of an antibody of the Diego antigen, anti-Di(a), in a tertiary care hospital to ascertain the need to include Di(a+) red cells for an antibody screen cell panel. Serological tests were performed by column agglutination technique using commercial reagents and following instruction as per kit insert. Di(a) antigen was found with a frequency of 2.1% among the Malaysians donors in three ethnic groups viz, Malay, Chinese and Indian. It was present among 1.25% of 401 Malay, 4.01% of Chinese and 0.88% of 114 Indian origin donors. None of the 1442 patients, including 703 antenatal outpatients, had anti-Di(a) in serum. The prevalence of Di(a) antigen was found among the donors of all the three ethnic background with varying frequency. Inclusion of Di(a+) red cells in routine antibody screening program would certainly help in detection of this clinically significant antibody and to provide safe blood transfusion in the Klang Valley, though the incidence of antibody appears to be very low in the region.
Bartonella spp. bacteremia in blood donors from Campinas, Brazil.
Pitassi, Luiza Helena Urso; de Paiva Diniz, Pedro Paulo Vissotto; Scorpio, Diana Gerardi; Drummond, Marina Rovani; Lania, Bruno Grosselli; Barjas-Castro, Maria Lourdes; Gilioli, Rovilson; Colombo, Silvia; Sowy, Stanley; Breitschwerdt, Edward B; Nicholson, William L; Velho, Paulo Eduardo Neves Ferreira
2015-01-01
Bartonella species are blood-borne, re-emerging organisms, capable of causing prolonged infection with diverse disease manifestations, from asymptomatic bacteremia to chronic debilitating disease and death. This pathogen can survive for over a month in stored blood. However, its prevalence among blood donors is unknown, and screening of blood supplies for this pathogen is not routinely performed. We investigated Bartonella spp. prevalence in 500 blood donors from Campinas, Brazil, based on a cross-sectional design. Blood samples were inoculated into an enrichment liquid growth medium and sub-inoculated onto blood agar. Liquid culture samples and Gram-negative isolates were tested using a genus specific ITS PCR with amplicons sequenced for species identification. Bartonella henselae and Bartonella quintana antibodies were assayed by indirect immunofluorescence. B. henselae was isolated from six donors (1.2%). Sixteen donors (3.2%) were Bartonella-PCR positive after culture in liquid or on solid media, with 15 donors infected with B. henselae and one donor infected with Bartonella clarridgeiae. Antibodies against B. henselae or B. quintana were found in 16% and 32% of 500 blood donors, respectively. Serology was not associated with infection, with only three of 16 Bartonella-infected subjects seropositive for B. henselae or B. quintana. Bartonella DNA was present in the bloodstream of approximately one out of 30 donors from a major blood bank in South America. Negative serology does not rule out Bartonella spp. infection in healthy subjects. Using a combination of liquid and solid cultures, PCR, and DNA sequencing, this study documents for the first time that Bartonella spp. bacteremia occurs in asymptomatic blood donors. Our findings support further evaluation of Bartonella spp. transmission which can occur through blood transfusions.
Bartonella spp. Bacteremia in Blood Donors from Campinas, Brazil
Pitassi, Luiza Helena Urso; de Paiva Diniz, Pedro Paulo Vissotto; Scorpio, Diana Gerardi; Drummond, Marina Rovani; Lania, Bruno Grosselli; Barjas-Castro, Maria Lourdes; Gilioli, Rovilson; Colombo, Silvia; Sowy, Stanley; Breitschwerdt, Edward B.; Nicholson, William L.; Velho, Paulo Eduardo Neves Ferreira
2015-01-01
Bartonella species are blood-borne, re-emerging organisms, capable of causing prolonged infection with diverse disease manifestations, from asymptomatic bacteremia to chronic debilitating disease and death. This pathogen can survive for over a month in stored blood. However, its prevalence among blood donors is unknown, and screening of blood supplies for this pathogen is not routinely performed. We investigated Bartonella spp. prevalence in 500 blood donors from Campinas, Brazil, based on a cross-sectional design. Blood samples were inoculated into an enrichment liquid growth medium and sub-inoculated onto blood agar. Liquid culture samples and Gram-negative isolates were tested using a genus specific ITS PCR with amplicons sequenced for species identification. Bartonella henselae and Bartonella quintana antibodies were assayed by indirect immunofluorescence. B. henselae was isolated from six donors (1.2%). Sixteen donors (3.2%) were Bartonella-PCR positive after culture in liquid or on solid media, with 15 donors infected with B. henselae and one donor infected with Bartonella clarridgeiae. Antibodies against B. henselae or B. quintana were found in 16% and 32% of 500 blood donors, respectively. Serology was not associated with infection, with only three of 16 Bartonella-infected subjects seropositive for B. henselae or B. quintana. Bartonella DNA was present in the bloodstream of approximately one out of 30 donors from a major blood bank in South America. Negative serology does not rule out Bartonella spp. infection in healthy subjects. Using a combination of liquid and solid cultures, PCR, and DNA sequencing, this study documents for the first time that Bartonella spp. bacteremia occurs in asymptomatic blood donors. Our findings support further evaluation of Bartonella spp. transmission which can occur through blood transfusions. PMID:25590435
Tan, Joanne C G; Yuan, Fang Fang; Daley, Jackie; Marks, Katherine; Flower, Robert L; Dyer, Wayne B
2018-05-01
D- individuals with previous D-incompatible pregnancies and/or blood transfusions, as well as those who are actively immunized with small-volume D+ red blood cells (RBCs), are stimulated to produce RhIG. Many factors could influence the stimulation of immunoglobulin production in response to foreign antigen (such as antigen immunogenicity and genetic factors), and it is unknown whether genetic markers could potentially identify responder anti-D donors. Anti-D donors were assigned a responder profile based on their serum RhIG levels (n = 431). A subset of donors (n = 272) had DNA extracted for polymerase chain reaction genotyping assays for target genes in antigen presentation and pathogen recognition receptors (TLR2, TLR4, CD14, FcγRIIA, and the MHC Class II locus HLA-DRB1). Statistical tests for associations between anti-D donor responder profiles and genetic factors were performed. A large proportion of our donors (38.7%) were classified as nonresponder donors, despite receiving multiple D+ RBC immunizations, whereas female sex was significantly associated with an all-responder profile (p < 0.001). The presence of the DRB1*15 allele and absence of the DRB1*04 allele were more likely to be associated with a responder anti-D donor, although not significantly after Bonferroni correction. A combination of the DRB1*15 allele and female sex was significantly associated with an anti-D donor responder profile. This study has identified female sex and the HLA-DRB1*15 allele as potentially useful markers that could be used to screen donors before entry into D immunization programs. © 2018 AABB.
Phokrai, Phornpun; Karoonboonyanan, Wisansanee; Thanapattarapairoj, Nida; Promkong, Chidchanok; Dulsuk, Adul; Koosakulnirand, Sirikamon; Canovali, Sasha; Indrawattana, Nitaya; Jutrakul, Yaowaruk; Wuthiekanun, Vanaporn; Limmathurotsakul, Direk; Brett, Paul J; Burtnick, Mary N; Lertmemongkolchai, Ganjana; Chantratita, Narisara
2018-05-30
Melioidosis is a fatal infectious disease caused by the environmental bacterium Burkholderia pseudomallei It is highly endemic in Asia and northern Australia but neglected in many other tropical countries. Melioidosis patients have a wide range of clinical manifestations and definitive diagnosis requires bacterial culture which can be time-consuming. A reliable rapid serological tool is greatly needed for disease surveillance and diagnosis. We previously demonstrated by ELISA that a hemolysin-coregulated protein (Hcp1) is a promising target for serodiagnosis of melioidosis. In this study, we have developed a rapid immunochromatography test (ICT) using Hcp1 as the target antigen (Hcp1-ICT). We evaluated this test for specific antibody detection using serum samples obtained from 4 groups of human subjects including : ( i ) 487 culture-confirmed melioidosis patients from four hospitals in northeast Thailand; ( ii ) 202 healthy donors from northeast Thailand; ( iii ) 90 U.S. healthy donors and ( iv ) 207 patients infected with other organisms. Compared to culture results as a gold standard, the sensitivity of ICT for all hospitals was 88.3 %. The specificities for Thai donors and U.S. donors were 86.1 % and 100 % , respectively and for other infections was 91.8 %. The results of the Hcp1-ICT demonstrated 92.4 % agreement with the Hcp1-ELISA with kappa value of 0.829 and is much improved when compared with the current serological method, indirect hemagglutination assay ( IHA ) ( 69.5 % sensitivity and 67.6 % specificity for Thais ). The Hcp1-ICT represents a potential point-of-care ( POC ) test and may be used to replace the IHA for screening of melioidosis in hospitals as well as resource-limited areas. Copyright © 2018 Phokrai et al.
Ghalavand, Zohreh; Heidary Rouchi, Alireza; Bahraminasab, Hassan; Ravanasa, Elham; Mirsamadi, Elnaz Sadat; Nodeh Farahani, Narges; Nikmanesh, Bahram
2018-02-03
Microbiological screening of tissue allografts is crucial to prevent the transmission of bacterial and fungal infections to transplant recipients. Klebsiella was the most prevalent and resistant contaminating microorganism observed in our setting in the Iranian Tissue Bank. This study was conducted to determine the presence of extended-spectrum β-lactamase (ESBL) genes, antimicrobial resistance patterns of Klebsiella pneumoniae isolates, and their clonal relationships in allograft materials. K. pneumoniae contaminating bone and other tissue allografts recovered from deceased donors were identified and ESBL isolates were detected using a phenotypic confirmatory method. Antimicrobial susceptibility testing was carried out using the disk diffusion method. Distribution of ESBL genes and molecular typing were performed using polymerase chain reaction (PCR) and Repetitive-element (rep-PCR) methods. Of 3828 donated tissues, 51 (1.3%) were found contaminated by K. pneumoniae isolates. Compared to tissue allografts from brain-dead, heart-beating tissue donors, allografts from donors with circulatory cessation were associated with a higher risk of K. pneumoniae contamination [odds ratio (OR), 1.2 (CI 95% 0.9-2.3) (P value < 0.001)]. Half of the isolates produced ESBL, and the rate of susceptibility to cephalosporins was 51%. Among isolates, 22 (43.1%) harbored CTX-M, 31 (60.8%) SHV, and 9 (17.6%) harbored TEM types. The rep-dendrogram indicated that clones having identical or related strains with a similar antibiotype were isolated in the same period. This study provides evidence that a single clone of K. pneumoniae contaminated tissue allografts recovered from many different donors. A single clone found on tissues from several donors suggests contamination of tissues from a single source such as the tissue recovery process and environment. Genomic DNA testing and clonality of contaminating bacteria using molecular methods can focus the epidemiologic investigation on the tissue allograft recovery process including a search for contamination of the tissue recovery room environment, recovery staff, recovery equipment, reagents, solutions and supplies.
Transfusion-acquired AIDS in Taiwan.
Yao, C; Wang, W W; Chung, Y M; Su, Y L; Liu, C Y; Chen, Y M
1996-01-01
Human immunodeficiency virus type 1 (HIV-1) can be transmitted through blood transfusion. The first transfusion-acquired immunodeficiency syndrome (AIDS) patient in Taiwan was a 46-year-old woman who received two units of whole blood during a hysterectomy at a provincial hospital in 1985. In 1991, she experienced a herpes zoster infection. In March 1993, she had extensive herpetic gingivostomatitis and another herpes zoster attack, and was treated at the same hospital. Two months later, she had oral candidiasis and was treated at a medical center. She was not tested for HIV-1 infection until she developed Pneumocystis carinii pneumonia in June 1993. In February 1994, and developed cytomegalovirus retinitis and died 6 months later. Donor blood given to the patients during the hysterectomy was HIV-1 positive. The donor's HIV infection was discovered in 1991 and he died of AIDS in 1993. As blood centers in Taiwan did not start screening for HIV-1 until January 1988, it is urgently recommended that any individual who received a blood transfusion between 1984 and 1987 in Taiwan and who currently experiences repeated episodes of opportunistic infections have an HIV-1 blood test. The receipt of a blood transfusion between 1984 and 1987 should be listed by the Department of Health as an indication for HIV-1 screening.
Best practice guidelines for the operation of a donor human milk bank in an Australian NICU.
Hartmann, B T; Pang, W W; Keil, A D; Hartmann, P E; Simmer, K
2007-10-01
Until the establishment of the PREM Bank (Perron Rotary Express Milk Bank) donor human milk banking had not occurred in Australia for the past 20 years. In re-establishing donor human milk banking in Australia, the focus of the PREM Bank has been to develop a formal and consistent approach to safety and quality in processing during the operation of the human milk bank. There is currently no existing legislation in Australia that specifically regulates the operation of donor human milk banks. For this reason the PREM Bank has utilised existing and internationally recognised management practices for managing hazards during food production. These tools (specifically HACCP) have been used to guide the development of Standard Operating Procedures and Good Manufacturing Practice for the screening of donors and processing of donor human milk. Donor screening procedures are consistent with those recommended by other human milk banks operating internationally, and also consistent with the requirements for blood and tissue donation in Australia. Controlled documentation and record keep requirements have also been developed that allow complete traceability from individual donation to individual feed dispensed to recipient and maintain a record of all processing and storage conditions. These operational requirements have been developed to reduce any risk associated with feeding pasteurised donor human milk to hospitalised preterm or ill infants to acceptable levels.
Blood transfusion in developing countries: problems, priorities and practicalities.
Wake, D J; Cutting, W A
1998-01-01
The acute medical services could not exist without blood transfusions--life-savers in many situations. But transfusions can also be a quick and easy route for the transmission of infectious agents such as HIV, HBV, HCV and malaria. Infection through blood supply is a major issue in all countries but particularly in those with economic constraints which limit safety. This study was carried out in India (March-May 1997) and involved centres in Delhi, Calcutta and Vellore. It examined many aspects of blood transfusion including donor screening, use of professional donors, blood testing and criteria for blood use. The many problems in Indian blood transfusion services are mirrored in other countries. Here we examine the problems, priorities and practicalities of blood transfusion particularly in developing countries.
Establishment of an oocyte donor program. Donor screening and selection.
Quigley, M M; Collins, R L; Schover, L R
1991-01-01
IVF with donated oocytes, followed by embryo placement in the uterus of a recipient who has been primed with exogenous steroids, is a successful treatment for special cases of infertility. Preliminary results indicate that the success rate in this situation is even greater than that usually seen with normal IVF (with placement of the embryos back into the uteri of the women from whom the oocytes were recovered). Although different sources for donated oocytes have been identified, the use of "excess" oocytes from IVF cycles and the attempted collection of oocytes at the time of otherwise indicated pelvic surgery have ethical and practical problems associated with their use. We have herein described the establishment of a successful program relying on anonymous volunteers who go through ovarian stimulation, monitoring, and oocyte recovery procedures solely to donate oocytes. The potential donors go through an exhaustive screening and education process before they are accepted in the program. Psychological evaluation of our potential donors indicated a great degree of turmoil in their backgrounds and a wide variety of motivations for actually participating. Despite the extensive educational and screening process, a substantial percentage of the donors did not complete a donation cycle, having either voluntarily withdrawn or been dropped because of lack of compliance. Further investigation of the psychological aspects of participating in such a program is certainly warranted. The use of donated oocytes to alleviate specific types of infertility is quite successful, but the application of this treatment is likely to be limited by the relative unavailability of suitable oocyte donors.
Harper, J C; Aittomäki, K; Borry, P; Cornel, M C; de Wert, G; Dondorp, W; Geraedts, J; Gianaroli, L; Ketterson, K; Liebaers, I; Lundin, K; Mertes, H; Morris, M; Pennings, G; Sermon, K; Spits, C; Soini, S; van Montfoort, A P A; Veiga, A; Vermeesch, J R; Viville, S; Macek, M
2018-01-01
Two leading European professional societies, the European Society of Human Genetics and the European Society for Human Reproduction and Embryology, have worked together since 2004 to evaluate the impact of fast research advances at the interface of assisted reproduction and genetics, including their application into clinical practice. In September 2016, the expert panel met for the third time. The topics discussed highlighted important issues covering the impacts of expanded carrier screening, direct-to-consumer genetic testing, voiding of the presumed anonymity of gamete donors by advanced genetic testing, advances in the research of genetic causes underlying male and female infertility, utilisation of massively parallel sequencing in preimplantation genetic testing and non-invasive prenatal screening, mitochondrial replacement in human oocytes, and additionally, issues related to cross-generational epigenetic inheritance following IVF and germline genome editing. The resulting paper represents a consensus of both professional societies involved.
Su, Dongdong; Teoh, Chai Lean; Kang, Nam-Young; Yu, Xiaotong; Sahu, Srikanta; Chang, Young-Tae
2015-03-01
In this paper, we report a new strategy for constructing a dye library with large Stokes shifts. By coupling a dark donor with BODIPY acceptors of tunable high quantum yield, a novel dark resonance energy transfer (DRET)-based library, named BNM, has been synthesized. Upon excitation of the dark donor (BDN) at 490 nm, the absorbed energy is transferred to the acceptor (BDM) with high efficiency, which was tunable in a broad range from 557 nm to 716 nm, with a high quantum yield of up to 0.8. It is noteworthy to mention that the majority of the non-radiative energy loss of the donor was converted into the acceptor's fluorescence output with a minimum leak of donor emission. Fluorescence imaging tested in live cells showed that the BNM compounds are cell-permeable and can also be employed for live-cell imaging. This is a new library which can be excited through a dark donor allowing for strong fluorescence emission in a wide range of wavelengths. Thus, the BNM library is well suited for high-throughput screening or multiplex experiments in biological applications by using a single laser excitation source. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Anand, Rohit; Song, Yang; Garg, Shashank; Girotra, Mohit; Sinha, Amitasha; Sivaraman, Anita; Phillips, Laila; Dutta, Sudhir K
2017-04-01
Fecal microbiota transplantation (FMT) is emerging as an effective therapy for the treatment of recurrent Clostridium difficile infection (RCDI). Selecting an appropriate donor is vital to the success of FMT. However, the relationship between age of donors and the efficacy of FMT has not been examined to date. The aim of this study was to examine the effect of age of healthy donors on their fecal microbiota and assess the impact of these changes on the clinical efficacy of FMT. This IRB-approved prospective study enrolled donors who were deemed healthy for FMT after careful detailed screening for infectious diseases per institutional protocol. The study was conducted between January 2011 and October 2014. Fecal samples were processed and analyzed using 16S rRNA gene amplicon sequencing. Differences in relative abundance and diversity of the donor fecal microbiota were analyzed in donors above and below 60 years of age. Effect of fecal microbiota from donors of different age groups on the efficacy of FMT was also evaluated. Twenty-eight healthy human subjects from ages 20-82 years were enrolled as donors for FMT. All patients receiving FMT from their respective donors had resolution of RCDI symptoms and had a negative C. difficile toxin test 4-12 weeks after FMT. Genomic analysis showed that the relative abundance of phylum Actinobacteria and family Bifidobacteriaceae was reduced in the donors ≥60 years of age (p < 0.05). However, Bacteroidetes-to-Fermicutes ratio did not demonstrate a significant change between the two groups. Furthermore, microbial diversity did not change significantly with advancing age. These observations suggest that aging in healthy donors is associated with compositional alterations in the fecal microbiome without change in the overall microbial diversity. These changes do not seem to affect the clinical efficacy of FMT in RCDI patients over 12 months.
Ignatova, E N; Tupoleva, T A; Ovchinnikova, E N; Romanova, T Yu; Yaroslavtseva, N G; Filatov, F P; Troitskaya, V V; Kuzmina, L A; Parovichnikova, E N; Gaponova, T V; Savchenko, V G
To evaluate the detection rate of markers for hepatitis B virus (HBV) in the blood samples taken from patients with blood system diseases, by applying the current approaches to examining donated blood and its components for markers of viral infections. The investigation included blood samples from patients with blood system diseases (n=364) and donors (n=5,011). The results of laboratory screening of donated blood samples (n=13,081) were retrospectively analyzed. Commercial kits of reagents were used for immunochemical assay and polymerase chain reaction. Patients with blood system diseases were recorded to have markers of active HBV infection in 12.6% of cases, anti-HBc in 31.3%, and anti-HBs in 37.6%. A retrospective analysis of the results of screening donated blood samples showed the presence of markers for active HBV infection in 0.28% of cases. A prospective examination of blood donors revealed markers of HBV infection in 4.83% of cases, including those of active forms in 0.54% and anti-HBc in 4.79%. The markers of active HBV infection in donors were only anti-HBc IgM in 0.42% of cases. The blood samples from donors with an anti-HBs titer of >200 mIU/ml contained anti-HBc IgM in 10.5%. In the last 5-7 years, the detection rate of markers of HBV infection in the blood samples of patients with blood system diseases have remained at a high level. Screening for decreed markers fails to identify people with inapparent infections among the donors. Even high anti-HBs concentrations in the donated blood may be a risk for HBV transmission by transfusion to a recipient.
Impact of the May 12, 2008, Earthquake on blood donations across five Chinese blood centers.
Liu, Jing; Huang, Yi; Wang, Jingxing; Bi, Xinhong; Li, Julin; Lu, Yunlai; Wen, Xiuqiong; Yao, Fuzhu; Dong, Xiangdong; He, Weilan; Huang, Mei; Ma, Hongli; Mei, Heili; King, Melissa; Wright, David J; Ness, Paul M; Shan, Hua
2010-09-01
On May 12, 2008, a severe earthquake struck China's Sichuan Province. The nationwide outpouring of charity resulted in a surge of subsequent blood donations. The quantity and quality of these donations were examined in comparison with routine donations. Whole blood and apheresis donations from five geographically different blood centers collected within 1 week postearthquake were compared with those collected during the rest of the year. Regional differences, demographic characteristics, first-time and repeat donor status, and infectious disease screening markers associated with these donations were compared by earthquake status using chi-square statistics. Poisson regression analysis examined the number of daily donations by earthquake status after adjusting for center, day of week, and seasonal variations. The number of daily donations across five blood centers increased from 685 on a typical day to 1151 in the postearthquake week. The surge was observed in both sexes and across different education levels, age, and ethnicity groups and three blood centers and was significant after adjusting for confounding covariates. The influx of first-time donors (89.5%) was higher than that of repeat donors (34%). There was a significant change in the overall screening reactive marker rates excluding alanine aminotransferase (2.06% vs. 1.72%% vs. 4.96%). However, when the individual screening test was analyzed separately, no significant differences were found. Timely donations in response to a disaster are crucial to ensure emergency blood transfusion. The dramatically increased postearthquake donations suggest that Chinese blood centers are capable of handling emergency blood needs. Measures to maintain blood safety should be taken in times of emergency. © 2010 American Association of Blood Banks.
Sellors, John W; Hayward, Robert; Swanson, Graham; Ali, Anita; Haynes, R Brian; Bourque, Ronald; Moore, Karen-Ann; Lohfeld, Lynne; Dalby, Dawn; Howard, Michelle
2002-01-01
Background Self-administered computer-assisted blood donor screening strategies may elicit more accurate responses and improve the screening process. Methods Randomized crossover trial comparing responses to questions on a computerized hand-held tool (HealthQuiz, or HQ), to responses on the standard written instrument (Donor Health Assessment Questionnaire, or DHAQ). Randomly selected donors at 133 blood donation clinics in the area of Hamilton, Canada participated from 1995 to 1996. Donors were randomized to complete either the HQ or the DHAQ first, followed by the other instrument. In addition to responses of 'yes' and 'no' on both questionnaires, the HQ provided a response option of 'not sure'. The primary outcome was the number of additional donors deferred by the HQ. Results A total of 1239 donors participated. Seventy-one potential donors were deferred as a result of responses to the questionnaires; 56.3% (40/71) were deferred by the DHAQ, and an additional 43.7% (31/71) were deferred due to risks identified by the HQ but not by the DHAQ. Fourteen donors self-deferred; 11 indicated on the HQ that they should not donate blood on that day but did not use the confidential self-exclusion option on the DHAQ, and three used the self-exclusion option on the DHAQ but did not indicate that they should not donate blood on the HQ. The HQ identified a blood contact or risk factor for HIV/AIDS or sexually transmitted infection that was not identified by the DHAQ in 0.1% to 2.7% of donors. Conclusion A self-administered computerized questionnaire may increase risk reporting by blood donors. PMID:12191432
Hepatitis B, HIV, and Syphilis Seroprevalence in Pregnant Women and Blood Donors in Cameroon
Mbah, Rahel; Rembert, Nicole J.; Tancho, Samuel; Halle-Ekane, Gregory E.; Enah, Comfort; Welty, Thomas K.; Tih, Pius M.; Tita, Alan T. N.
2016-01-01
Objectives. We estimated seroprevalence and correlates of selected infections in pregnant women and blood donors in a resource-limited setting. Methods. We performed a cross-sectional analysis of laboratory seroprevalence data from pregnant women and voluntary blood donors from facilities in Cameroon in 2014. Rapid tests were performed to detect hepatitis B surface antigen, syphilis treponemal antibodies, and HIV-1/2 antibodies. Blood donations were also tested for hepatitis C and malaria. Results. The seroprevalence rates and ranges among 7069 pregnant women were hepatitis B 4.4% (1.1–9.6%), HIV 6% (3.0–10.2%), and syphilis 1.7% (1.3–3.8%) with significant variability among the sites. Correlates of infection in pregnancy in adjusted regression models included urban residence for hepatitis B (aOR 2.9, CI 1.6–5.4) and HIV (aOR 3.5, CI 1.9–6.7). Blood donor seroprevalence rates and ranges were hepatitis B 6.8% (5.0–8.8%), HIV 2.2% (1.4–2.8%), syphilis 4% (3.3–4.5%), malaria 1.9%, and hepatitis C 1.7% (0.5–2.5%). Conclusions. Hepatitis B, HIV, and syphilis infections are common among pregnant women and blood donors in Cameroon with higher rates in urban areas. Future interventions to reduce vertical transmission should include universal screening for these infections early in pregnancy and provision of effective prevention tools including the birth dose of univalent hepatitis B vaccine. PMID:27578957
Toxoplasmosis in Blood Donors: A Systematic Review and Meta-Analysis.
Foroutan-Rad, Masoud; Majidiani, Hamidreza; Dalvand, Sahar; Daryani, Ahmad; Kooti, Wesam; Saki, Jasem; Hedayati-Rad, Faezeh; Ahmadpour, Ehsan
2016-07-01
Transfusion-transmissible infections include pathogens that may cause severe and debilitating diseases. Toxoplasmosis is a cosmopolitan neglected parasitic infection that can lead to severe complications including death in immune-compromised patients or following infection in utero. Multiple studies have demonstrated the transmission of Toxoplasma gondii by blood transfusion. The objective of this review was to comprehensively assess the seroprevalence rate of Toxoplasma in blood donors from a worldwide perspective. Seven electronic databases (PubMed, Science Direct, Web of Science, Scopus, Cochrane, Ovid, and Google Scholar) were searched using medical subject headings terms. A total of 43 records met the inclusion criteria in which 20,964 donors were tested during the period from January 1980 to June 2015. The overall weighted prevalence of exposure to toxoplasmosis in blood donors was 33% (95% confidence interval [CI], 28%-39%). The seroprevalences of immunoglobulin (Ig)M and both IgG and IgM antibodies were 1.8% (95% CI, 1.1%-2.4%) and 1.1% (95% CI, 0.3%-1.8%), respectively. The highest and the lowest seroprevalences of toxoplasmosis were observed in Africa (46%; 95% CI, 14%-78%) and in Asia (29%; 95% CI, 23%-35%), respectively. Brazil (75%) and Ethiopia (73%) were identified as countries with high seroprevalence. Because positive serology does not imply infectiousness and because seroprevalence is high in some nations, a positive serology test result alone cannot be used as an effective method for donor screening. Future research for methods to prevent transfusion-transmitted toxoplasmosis may derive benefit from studies conducted in areas of high endemicity. Copyright © 2016 Elsevier Inc. All rights reserved.
Ethical Dilemmas for Oocyte Donations: Slippery Slope for Conflicts of Interest.
Tulay, Pinar
2016-01-01
Oocyte donations have increased with improvements in oocyte cryopreservation procedures in recent years. Women with medical conditions that require chemotherapy or radiotherapy have begun to opt for oocyte cryo¬preservation prior to their treatment or to enroll in an oocyte donation program. Alternatively, some women apply for "third-party" oocyte donation programs for nonmedical reasons such as delayed childbearing. Although society seems to accept oocyte donations for medical reasons, it appears that there are still some moral issues surrounding nonmedical oocyte donations. In this review, the ethical aspects of oocyte donations and donors' perspectives are discussed. With developing technologies, the genetic screening of donors has expanded to include diseases. This review explores the ethical issues involved in genetic screening of gamete donors.
Probing transplant and living donor candidates about their participation in organ vending.
Bramstedt, Katrina A
2010-09-01
The selling of human organs for transplant is illegal in the United States and in most countries; however, such transactions still occur. Transplant hospitals and their personnel have multiple ethical duties, including (1) protecting the safety of their living donors and transplant recipients and (2) protecting the integrity of living donation and transplantation as clinical practices. To date, few psychosocial screening tools exist that pertain specifically to a person's risk or intent of pursuing organ vending (buying or selling). This article presents a series of transplant ethics case consultations that spawned the creation of a set of behavioral prompts for teams to probe with regard to organ vending when screening candidates about their suitability for participation as living donors or transplant recipients.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
... approaches. The document does not apply to devices that are intended to screen donors of blood and blood components, and donors of human cells, tissues, and cellular and tissue-based products for communicable...
36 CFR 1256.32 - How do I request access to restricted information in donated historical materials?
Code of Federal Regulations, 2010 CFR
2010-07-01
... amount of effort. For files that NARA previously screened, you may cite the reference to the withheld..., a donor or his or her representative reserves the right to determine whether the donor's materials...
Ueck, Christopher; Volksdorf, Thomas; Houdek, Pia; Vidal-y-Sy, Sabine; Sehner, Susanne; Ellinger, Bernhard; Lobmann, Ralf; Larena-Avellaneda, Axel; Reinshagen, Konrad; Ridderbusch, Ina; Kohrmeyer, Klaas; Moll, Ingrid; Daniels, Rolf; Werner, Philipp; Merfort, Irmgard; Brandner, Johanna M.
2017-01-01
Diabetes mellitus is a frequent cause for chronic, difficult-to-treat wounds. New therapies for diabetic wounds are urgently needed and in-vitro or ex-vivo test systems are essential for the initial identification of new active molecules. The aim of this study is to compare in-vitro and ex-vivo test systems for their usability for early drug screening and to investigate the efficacy of a birch bark triterpene extract (TE) that has been proven ex-vivo and clinically to accelerate non-diabetic wound healing (WH), in a diabetic context. We investigated in-vitro models for diabetic WH, i.e. scratch assays with human keratinocytes from diabetic donors or cultured under hyperglycaemic conditions and a newly developed porcine ex-vivo hyperglycaemic WH model for their potential to mimic delayed diabetic WH and for the influence of TE in these test systems. We show that keratinocytes from diabetic donors often fail to exhibit significantly delayed WH. For cells under hyperglycaemic conditions significant decrease is observed but is influenced by choice of medium and presence of supplements. Also, donor age plays a role. Interestingly, hyperglycaemic effects are mainly hyperosmolaric effects in scratch assays. Ex-vivo models under hyperglycaemic conditions show a clear and substantial decrease of WH, and here both glucose and hyperosmolarity effects are involved. Finally, we provide evidence that TE is also beneficial for ex-vivo hyperglycaemic WH, resulting in significantly increased length of regenerated epidermis to 188±16% and 183±11% (SEM; p<0.05) compared to controls when using two different TE formulations. In conclusion, our results suggest that microenvironmental influences are important in WH test systems and that therefore the more complex hyperglycaemic ex-vivo model is more suitable for early drug screening. Limitations of the in-vitro and ex-vivo models are discussed. Furthermore our data recommend TE as a promising candidate for in-vivo testings in diabetic wounds. PMID:28046026
Risk Factors for Bartonella species Infection in Blood Donors from Southeast Brazil.
Diniz, Pedro Paulo Vissotto de Paiva; Velho, Paulo Eduardo Neves Ferreira; Pitassi, Luiza Helena Urso; Drummond, Marina Rovani; Lania, Bruno Grosselli; Barjas-Castro, Maria Lourdes; Sowy, Stanley; Breitschwerdt, Edward B; Scorpio, Diana Gerardi
2016-03-01
Bacteria from the genus Bartonella are emerging blood-borne bacteria, capable of causing long-lasting infection in marine and terrestrial mammals, including humans. Bartonella are generally well adapted to their main host, causing persistent infection without clinical manifestation. However, these organisms may cause severe disease in natural or accidental hosts. In humans, Bartonella species have been detected from sick patients presented with diverse disease manifestations, including cat scratch disease, trench fever, bacillary angiomatosis, endocarditis, polyarthritis, or granulomatous inflammatory disease. However, with the advances in diagnostic methods, subclinical bloodstream infection in humans has been reported, with the potential for transmission through blood transfusion been recently investigated by our group. The objective of this study was to determine the risk factors associated with Bartonella species infection in asymptomatic blood donors presented at a major blood bank in Southeastern Brazil. Five hundred blood donors were randomly enrolled and tested for Bartonella species infection by specialized blood cultured coupled with high-sensitive PCR assays. Epidemiological questionnaires were designed to cover major potential risk factors, such as age, gender, ethnicity, contact with companion animals, livestock, or wild animals, bites from insects or animal, economical status, among other factors. Based on multivariate logistic regression, bloodstream infection with B. henselae or B. clarridgeiae was associated with cat contact (adjusted OR: 3.4, 95% CI: 1.1-9.6) or history of tick bite (adjusted OR: 3.7, 95% CI: 1.3-13.4). These risk factors should be considered during donor screening, as bacteremia by these Bartonella species may not be detected by traditional laboratory screening methods, and it may be transmitted by blood transfusion.
Sachdev, Suchet; Mittal, Kshitija; Patidar, Gopal; Marwaha, Neelam; Sharma, Ratti Ram; Duseja, Ajay Kumar; Chawla, Yogesh Kumar; Arora, Sunil Kumar
2015-09-01
Donor notification and counselling transforms the legal and ethical requirement of disclosure of transfusion transmissible infection (TTI) in a blood donor into practice. The present study was done to assess the response to the disclosure of TTI reactivity results in blood donors, assess the risk factors in blood donors and follow the compliance of the disclosure and clinical referral in a population of blood donors who are difficult to convince that they may be harbouring infections apparently in a healthy state today but with possible clinical disease consequences in the future. A retrospective study was conducted from April 2011 to November 2012. Screening was done using third generation ELISA kits used according to the manufacturer's directions; these kits were approved for use in blood banks by the Drug Controller General of India. Those testing repeat reactive were referred for further confirmation and management. The total number of TTI reactive donors was 787 (0.93 %, N = 83,865). The observed response rate in the present study is 21.6 % (167, N = 787). The risk factors for acquiring infections in TTI reactive donors were statistically significant history of high risk behaviour (20.3 %) for human immunodeficiency virus infection and history of jaundice in themselves, family or close contacts (16.1 %) for hepatitis B virus infection. One hundred and ten (65.8 %) of the referred donors were on outpatient clinical care when post-referral follow up was conducted. The study emphasises on continuing sensitization of blood donation camp organisers to the need of privacy during blood donor selection. The study also stresses the need to strengthen the pre-donation counselling at outdoor blood donation at the same time raise awareness amongst blood donors about the importance of post-donation counselling and follow up.
Pereira, A; Sanz, C
2000-10-01
Cost-effectiveness analyses are needed to decide the value of further expansion of the screening protocols for HCV in blood donors. However, such analyses are hampered by imperfect knowledge of the health and economic repercussions of posttransfusion hepatitis C (PTHC). A Monte Carlo simulation of a Markov model representing the outcomes of patients transfused with HCV-infective blood was used to estimate the health and economic impact of PTHC and to calculate the cost-effectiveness ratio of various HCV screening methods. Median survival for hypothetical patients with PTHC and for controls without hepatitis was 11.25 and 11.75 years, respectively. Overall, 12.3 percent of patients receiving HCV-infective blood will develop chronic hepatitis, 9.3 percent will progress to liver failure, and 9. 25 percent will eventually die of liver disease after a median time of 20.75 years (range, 6-70). Ninety-one percent of the infected blood recipients had no reduction in life expectancy due to PTHC, and the average loss per patient was 0.754 years. The present value of the lifetime health costs incurred by patients with PTHC is $6330 per case. HCV antibody testing increases the patients' life expectancy by 20.4 hours per blood collection tested, and it results in net savings by decreasing the number of patients that will require treatment for liver disease in the future. Adding HCV NAT increases the patients' life expectancy by 0.08 hours per blood collection tested, at a cost-effectiveness ratio of $1,829,611 per QALY gained. PTHC has low health benefits because of the advanced age of many blood recipients. Testing donors for HCV antibodies results in net savings for the health care system, despite low health benefits. Adding HCV NAT would produce little additional gain at a very high cost.
Wright, K C; Feeney, A M
1998-01-01
This study was undertaken to assess the application of the British Paediatric Association's (BPA) published guidelines to the bacteriological screening of breast milk donated to a District General Hospital milk bank. Samples of donated milk were subjected to bacterial counts and provisional identification after both 24 and 48 h incubation on cysteine lactose electrolyte-deficient (CLED) and Columbia blood agar. 21.8% (76 out of 348) donations of milk failed to reach the BPA acceptable criteria. The organisms responsible for the rejection of these samples were all evident within 24 h incubation, and were not significantly confined to one medium. A large percentage of rejected samples originated from a small number of donor mothers; 63.2% came from one donor. In applying BPA guidelines, both CLED and Columbia blood agar were found to be equally effective in screening for unacceptable organisms in prepasteurization donated breast milk. The 24 h period allowed for bacteriological screening, prior to pasteurization of milk samples, was sufficient to allow the growth of all potentially pathogenic bacteria in this study. To prevent the donation of consistently contaminated milk, more active communication between the milk bank staff and the donor is recommended.
Hospital-based allogenic bone bank--10-year experience.
Hou, C-H; Yang, R-S; Hou, S-M
2005-01-01
Bone banking in a hospital provides resources of allogenic bone grafts. However, they may transmit infection from donor to recipient. We found few reports discussing the infection rate and monitoring processes associated with bone banks. The discard rate using the screening test was 18.5% (309/1674) in this series. The leading cause was hepatitis B antigen (HBsAg) positive donor serum (67%), followed by Venereal Disease Research Laboratory (VDRL) positive donor serum (15%), and anti-hepatitis C virus (HCV) positive donor serum (12%). The overall infection rate in the recipients was 1.3% (17/1365). Among 1353 implanted allografts, 22 cases (1.6%) had a positive swab culture result after thawing. Only four out of these 22 cases (18.2%) developed infection. However, the wound cultures of the infected recipients were different from the swab culture of thawing allografts except in one case. Among the 1331 recipients with sterile allograft bones, 13 (1%) were found to have infection. In conclusion, our bone bank operates under a strict monitoring system which results in a low infection rate. The recipient's status, the aseptic technique and environment during operation is likely to be more critical in prevention of allograft-related infection.
Factors influencing the decision to donate: racial and ethnic comparisons.
Glynn, Simone A; Schreiber, George B; Murphy, Edward L; Kessler, Debra; Higgins, Martha; Wright, David J; Mathew, Sunitha; Tu, Yongling; King, Melissa; Smith, James W
2006-06-01
Understanding factors that encourage different racial and ethnic groups to donate is crucial for donor recruitment and retention. A 28-item self-administered questionnaire was completed in 2003 by 1862 Asian, 1479 black, 1641 Hispanic, and 2940 White US donors who had given whole blood within the past year. With a 1 to 5 scale, donors were asked to rate the importance of 17 factors in their last donation decision. Logistic regression was conducted to compare the odds of a factor being important or very important (score of 4 or 5) in one's decision to donate between race or ethnic groups, stratified by first-time and repeat status. More than 90 percent of each respondent group cited a desire, responsibility, or perceived duty to help others as an important or very important motivator. Being asked to donate at work was also an important motivator for all race and ethnic groups (56-70%). Getting the results of a health screen appealed to many (approx. 30% found it important or very important) and was most important to Black and Hispanic donors (odds ratios of 1.3-1.9 compared to White donors; p<0.003). Recruitment and retention programs should build on people's sense of social responsibility. Direct requests to donate are particularly effective motivators. Of a variety of incentives evaluated, offering more comprehensive health screens may motivate many donors, especially Black and Hispanic donors.
Hill, Joshua A; Magaret, Amalia S; Hall-Sedlak, Ruth; Mikhaylova, Anna; Huang, Meei-Li; Sandmaier, Brenda M; Hansen, John A; Jerome, Keith R; Zerr, Danielle M; Boeckh, Michael
2017-08-24
Human herpesvirus 6 (HHV-6) species have a unique ability to integrate into chromosomal telomeres. Mendelian inheritance via gametocyte integration results in HHV-6 in every nucleated cell. The epidemiology and clinical effect of inherited chromosomally integrated HHV-6 (iciHHV-6) in hematopoietic cell transplant (HCT) recipients is unclear. We identified 4319 HCT donor-recipient pairs (8638 subjects) who received an allogeneic HCT and had archived pre-HCT peripheral blood mononuclear cell samples. We screened these samples for iciHHV-6 and compared characteristics of HCT recipients and donors with iciHHV-6 with those of recipients and donors without iciHHV-6, respectively. We calculated Kaplan-Meier probability estimates and Cox proportional hazards models for post-HCT outcomes based on recipient and donor iciHHV-6 status. We identified 60 HCT recipients (1.4%) and 40 donors (0.9%) with iciHHV-6; both recipient and donor harbored iciHHV-6 in 13 HCTs. Thus, there were 87 HCTs (2%) in which the recipient, donor, or both harbored iciHHV-6. Acute graft-versus-host disease (GVHD) grades 2-4 was more frequent when recipients or donors had iciHHV-6 (adjusted hazard ratios, 1.7-1.9; P = .004-.001). Cytomegalovirus viremia (any and high-level) was more frequent among recipients with iciHHV-6 (adjusted HRs, 1.7-3.1; P = .001-.040). Inherited ciHHV-6 status did not significantly affect risk for chronic GVHD, hematopoietic cell engraftment, overall mortality, or nonrelapse mortality. Screening for iciHHV-6 could guide donor selection and post-HCT risk stratification and treatment. Further study is needed to replicate these findings and identify potential mechanisms. © 2017 by The American Society of Hematology.
van Roeden, Sonja E; Holsboer, Eleonoor W; Oosterheert, Jan Jelrik; van Kats, Jorge P; van Beckhoven, Jacqueline; Hogema, Boris M; van Wijk, Marja J
2018-01-01
Background After a large Q fever outbreak in the Netherlands in the period from 2007 to 2010, the risk of Q fever transmission through tissue and cell transplantation from undiagnosed chronic Q fever cases became a potential issue. Aim: We aimed to evaluate the risk of Q fever transmission through tissue and cell transplantation. Methods: We performed a retrospective observational cohort study among 15,133 Dutch donors of tissues and stem cells from 2010 to 2015 to assess seroprevalence of Coxiella burnetii antibodies, to identify factors associated with presence of C. burnetii antibodies, and to assess the proportion of undiagnosed chronic Q fever cases. Results: The study population consisted of 9,478 (63%) femoral head donors, 5,090 (34%) post-mortal tissue donors and 565 (4%) cord blood donors. Seroprevalence of C. burnetii antibodies gradually decreased after the outbreak, from 2.1% in 2010 to 1.4% in 2015, with a significant trend in time (p < 0.001). Of 301 seropositive donors, seven (2.3%) were newly detected with chronic Q fever (0.05% of all screened donors). Conclusion: This study shows that seroprevalence of C. burnetii antibodies among donors of tissues and cells in the Netherlands after 2014 was similar to pre-outbreak levels in the general population. The proportion of newly detected chronic Q fever patients among donors of tissues and cells was smaller than 0.1%. This study may prompt discussion on when to terminate the screening programme for chronic Q fever in donors of tissues and cells in the Netherlands. PMID:29510781
van Roeden, Sonja E; Holsboer, Eleonoor W; Oosterheert, Jan Jelrik; van Kats, Jorge P; van Beckhoven, Jacqueline; Hogema, Boris M; van Wijk, Marja J
2018-03-01
BackgroundAfter a large Q fever outbreak in the Netherlands in the period from 2007 to 2010, the risk of Q fever transmission through tissue and cell transplantation from undiagnosed chronic Q fever cases became a potential issue. Aim: We aimed to evaluate the risk of Q fever transmission through tissue and cell transplantation. Methods: We performed a retrospective observational cohort study among 15,133 Dutch donors of tissues and stem cells from 2010 to 2015 to assess seroprevalence of Coxiella burnetii antibodies, to identify factors associated with presence of C. burnetii antibodies, and to assess the proportion of undiagnosed chronic Q fever cases. Results: The study population consisted of 9,478 (63%) femoral head donors, 5,090 (34%) post-mortal tissue donors and 565 (4%) cord blood donors. Seroprevalence of C. burnetii antibodies gradually decreased after the outbreak, from 2.1% in 2010 to 1.4% in 2015, with a significant trend in time (p < 0.001). Of 301 seropositive donors, seven (2.3%) were newly detected with chronic Q fever (0.05% of all screened donors). Conclusion: This study shows that seroprevalence of C. burnetii antibodies among donors of tissues and cells in the Netherlands after 2014 was similar to pre-outbreak levels in the general population. The proportion of newly detected chronic Q fever patients among donors of tissues and cells was smaller than 0.1%. This study may prompt discussion on when to terminate the screening programme for chronic Q fever in donors of tissues and cells in the Netherlands.
Biffin, A H; Jones, M A; Palmer, S R
1993-07-01
The routine use of ELISA and complement fixation tests in the diagnosis of suspected clinical cases of hydatid disease was evaluated. In the ELISA test, dialysed and filtered sheep cyst fluid was used as antigen and two positive cut-off points--+3SD and +2SD of the mean absorbance values of the control sera--were evaluated. The predictive values of ELISA tests were 82% and 90% for positive tests, and 86% and 82% for negative tests, respectively with the two cut-off points. In a population survey of blood donors and veterinary workers in Powys, 4% and 8%, respectively, had ELISA values above the lower cut-off point. However, it would not be appropriate to use the same test for diagnostic population screening in Wales since the predictive value of the test is likely to be very low in this setting. Serological surveys with the ELISA may be of use in monitoring the progress of the South Powys Hydatid Control Programme. The use of cumulative percentages was found to be a useful method of comparing whole distributions of results in different populations.
Synthesis of medium-chain length capsinoids from coconut oil catalyzed by Candida rugosa lipases.
Trbojević Ivić, Jovana; Milosavić, Nenad; Dimitrijević, Aleksandra; Gavrović Jankulović, Marija; Bezbradica, Dejan; Kolarski, Dušan; Veličković, Dušan
2017-03-01
A commercial preparation of Candida rugosa lipases (CRL) was tested for the production of capsinoids by esterification of vanillyl alcohol (VA) with free fatty acids (FA) and coconut oil (CO) as acyl donors. Screening of FA chain length indicated that C8-C12 FA (the most common FA found in CO triglycerides) are the best acyl-donors, yielding 80-85% of their specific capsinoids. Hence, when CO, which is rich in these FA, was used as the substrate, a mixture of capsinoids (vanillyl caprylate, vanillyl decanoate and vanillyl laurate) was obtained. The findings presented here suggest that our experimental method can be applied for the enrichment of CO with capsinoids, thus giving it additional health promoting properties. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zheng, Xiaofan; Ding, Wei; Li, Gan; Wu, Yaling; Wu, Danxiao; Zhu, Hong; He, Ji; Wang, Bin; Zhao, Longyou; Zhu, Faming; Lv, Hangjun
2015-07-01
The high prevalence of hepatitis B and C viruses (HBV and HCV), paralleling the growing epidemic of human immunodeficiency virus (HIV) and Treponema pallidum (TP) infections in the general population, poses a great threat to blood safety in China. This study investigated the prevalence of serological markers for causative agents of transfusion-transmissible infections (TTI), i.e. HBV, HCV, HIV and TP, among volunteer blood donors in five cities/regions of Zhejiang Province, China. We investigated whole blood and apheresis donations collected at the Blood Services in five cities/regions in Zhejiang Province between January 1, 2006 and December 31, 2012. Two rounds of serological testing were performed for HBsAg, anti-HCV, anti-HIV1/2 and anti-TP using different kits. The rates of serological positivity were calculated and further analysis was performed to examine the association between donors' characteristics and seroprevalence. Of the 1,615,120 donations, approximately 40% came from first-time donors and 60% from repeat donors. The overall seroprevalence rates of HBV, HCV, HIV and TP were 0.51%, 0.25%, 0.15% and 0.52%, respectively. The overall prevalences of HCV and HIV remained relatively steady, whereas the prevalence of TP increased sharply after 2010. However, the prevalence of TTI agents varied among volunteer blood donors in different cities/regions and demographic groups. We collected data on the seroprevalence of TTI agents among volunteer blood donors. Although the risk of TTI is low in China compared to that in some developing countries, sensitive screening methods and recruitment of regular donors are still very important for blood safety and availability.
Gómez, Lina Andrea; Peñuela, Oscar; Higuera, Fernando
2014-01-01
The main purpose of this study was to establish the prevalence of antibodies against five transfusion-transmissible infections (TTIs) in blood donors from one of the most important blood banks in Colombia. A cross-sectional, descriptive and case control study was performed from a database of Higuera-Escalante blood bank, for a period of a year. Serum was used for donor screening. Surface antigens for hepatitis B (HbsAg), anti-hepatitis C antibodies, Chagas disease, syphilis, and HIV were identified. Chemiluminescent Microparticle Immunoassay (CMIA, Abbott Diagnostics) was performed. From 41,575 total donors analyzed, 1,226 were reactive for any of the infectious markers (total prevalence of 2.95%). The prevalence of specific infections was: Chagas disease 0.49%, HbsAg 0.21%, HCV 0.45%, HIV 0.12%, and syphilis 1.68%. Reactivity was more frequent in men (n = 785, 64%) with a mean age of 36.35 years. HIV was present in the youngest donors with a mean age of 26.5 years (IC 95%: 23.6 - 27.6); on the other hand, Chagas disease was found in the oldest donor population, with a mean age of 40 years (IC 95%: 39.1 - 41.3). Identifying the prevalence of circulating antibodies against transfusion transmissible infections allows us to establish an epidemiological profile of donors inhabiting the geographic catchment area of our blood bank. Total prevalence in this study was 2.95% for any of the five markers. Syphilis prevalence demonstrates its high distribution within the blood donor population of our country, although this result could be influenced by the high rate of false-reactive test. Chagas disease is endemic in Santander, Colombia, which correlates with the results obtained in this study.
de Morais, Márcia Poinho EncarnaçÃo; Gato, Cynara Melo; Maciel, Lucinei Alves; Lalwani, Pritesh; Costa, Cristóvão Alves; Lalwani, Jaila Dias Borges
2017-01-01
ABSTRACT Introduction: Human T-lymphotropic virus type 1 and 2 (HTLV-1/2) is endemic in Brazil, but few studies have investigated the seroprevalence of HTLV and its subtypes among blood donors in the capital city Manaus, Amazonas State, Brazil. Aim: To estimate the seroprevalence of HTLV-1/2 and to identify circulating subtypes among blood donors in Manaus. Materials and Methods: Blood donors (2001-2003) were screened for HTLV-1/2 antibodies by ELISA. Positive results were confirmed and subtyped by Western blot assays. Prevalence rates were calculated and compared with demographic data. Results: Among the 87,402 individuals screened, 116 (0.13%) were seropositive for HTLV-1/2. A second sample (76/116) was collected and retested by HTLV-1/2 ELISA, of which only 41/76 were positive. Western blot confirmed HTLV infection in 24/41 retested blood donors [HTLV-1 (n=16), HTLV-2 (n=5) and HTLV-untypable (n=3)]. Discussion: HTLV-1 and HTLV-2 are prevalent among blood donors in Manaus. However, additional studies are needed to comprehend the epidemiology of HTLV-1/2 in Amazonas not only to understand the pathophysiology of the disease providing adequate medical assistance, but also to reduce or block virus transmission. PMID:29267588
Post-transplantation HTLV-1 myelopathy in three recipients from a single donor.
Zarranz Imirizaldu, J J; Gomez Esteban, J C; Rouco Axpe, I; Perez Concha, T; Velasco Juanes, F; Allue Susaeta, I; Corral Carranceja, J M
2003-08-01
This paper reports for the first time three cases of infection by HTLV-I via organ transplantation; all the organs coming from the same asymptomatic infected donor. The need is considered for the implementation of compulsory screenings for HTLV antibodies on organ donors and on blood banks. The determination of antibodies for HTLV-I/II on samples of serum and cerebral spinal fluid from the patients and the donor was performed by enzyme immunoassay and western blot. Analysis of proviral DNA was performed by polymerase chain reaction. To detect changes in the sequence of amino acids, the tax gene was sequentiated, amplified, and compared with ATK prototype stocks. Spinal cord magnetic resonance imaging, cerebral spinal fluid, and somatosensory evoked potential studies were carried out in all patients. All three transplanted patients developed a myelopathy within a very short period of time. In all three patients and donor the virus belonged to the Cosmopolitan A subtype. The homology of HTLV-I sequences recovered from the patients and donor was 100% in all four cases. Proviral load was high in all three patients. The factors that certainly contributed to the infection in the first place, and the development of the disease later, were on the one hand the high proviral load and their immunosuppressed condition, and on the other the virus genotype, which proved to be an aggressive variant. However, the analysis of the histocompatibility antigen showed that two of the patients carried an haplotype that has been associated with a lower risk of developing this disease. It is argued that, although in Spain and other European countries there is not compulsory screening for HTLV antibodies because of the studies that show a low seroprevalence, in view of the cases here reported, and to avoid the serious consequences that such infection has on transplanted patients, compulsory screenings, both on organ donors and on blood banks, should be implemented.
Taylor, C A; Overstreet, J W; Samuels, S J; Boyers, S P; Canfield, R E; O'Connor, J F; Hanson, F W; Lasley, B L
1992-06-01
To develop an economical, nonradiometric immunoenzymometric assay (IEMA) for the detection of urinary human chorionic gonadotropin (hCG) in studies of early fetal loss. To be effective, the IEMA must have a sensitivity equal to the standard immunoradiometric assay (IRMA) and sufficient specificity to eliminate the need for screening most nonconceptive cycles with the expensive and labor-intensive IRMA. Two different assays were used to measure hCG in daily early morning urine samples from potential conceptive cycles. Women undergoing donor artificial insemination (AI) were evaluated in a prospective study. Ninety-two women volunteers were selected on the basis of apparent normal reproductive health. Artificial insemination with nonfrozen donor semen was performed by cervical cup twice each menstrual cycle at 48-hour intervals, and daily urine samples were self-collected throughout the menstrual cycle. An IEMA was developed to detect urinary hCG using the same antibodies as in the standard IRMA; a study was designed to determine whether this nonradiometric assay could successfully detect the early fetal loss that was detected by the IRMA. Of 224 menstrual cycles analyzed by both assays, a total of six early fetal losses were detected by the IRMA. When the tentative screening rule was set to allow all six of these losses and 95% of future losses to be detected by the IEMA, an additional 34 false-positive results were detected by the IEMA. The specificity of the IEMA with this rule was calculated to be 84%. An IEMA based on the same antibodies used for the standard IRMA can serve as an efficient screening assay for the detection of early fetal loss. When the IEMA is used in this manner, nearly 80% of screened menstrual cycles can be eliminated without further testing by the IRMA.
Mohammed, Yusuf; Bekele, Alemayehu
2016-02-27
A transfusion transmissible infection (TTI) is any infection that is transmissible from person to- person through parenteral administration of blood or blood products. The magnitude of transfusion-transmitted infections (TTI) varies from country to country depending on TTI's load in that particular population. Measuring their severity, WHO (World Health Organization) has recommended pre-transfusion blood test for Human immunodeficiency virus (HIV), Hepatitis B virus (HBV), Hepatitis C Virus (HCV) and Syphilis as mandatory. The aim of the current study was to assess the trend and prevalence of TTI among blood donors in Jijiga Blood Bank between 2010 and 2013. A Retrospective cross-sectional study was conducted by reviewing the records from 2010 to 2013 at Jijiga Blood Bank. All blood donors who presented to the blood bank and screened for TTI during the study period were included. The data was collected, entered and analyzed using Epi Info 3.5.1 & Microsoft Excel 2007. The descriptive statistics were determined in means of percentages. Chi-square was used for trend analysis and p-value was used to declare the statistical significance between the variable. There were a total of 4224 people donated blood during study period. Males formed the majority of the donor population accounting for 4171 (98.7%). Majority 4139 (98%) of donors were Replacement donors. The overall prevalence of transfusion-transmitted infection was 487/4224 (11.5%). The prevalence for HBsAg, HCV, HIV, & Syphilis antibodies was 460 (10. 9%), 17 (0.4%), 6 (0.1%) and 4 (0.1%) respectively. Majority 460/487 (94.5%) of infection was HBsAg. Statistically significant difference was observed in number of donation as well as sero-positivity from year 2010 to 2013 (Chi-square 9.24, p value = 0.02), in Trends of HBsAg from year to year (Chi-square 11.14, p value = 0.01), HIV virus was seen as the age of donors increases (Chi-square 8.37, p value = 0.01) and There was also statistically significance difference (p value = 0.01) in prevalence of HBsAg distribution by sex. The present study clearly documents high Seroprevalence (487 out of 4,224, 11.5%) of TTI, low percentage of voluntary donors and low participation of female donors. Promoting the culture of voluntary donors, recruitment of female blood donors and proper testing of donor's blood by using standard methods are recommended.
West Nile Virus workshop: scientific considerations for tissue donors.
Brubaker, Scott A; Robert Rigney, P
2012-08-01
This report contains selected excerpts, presented as a summary, from a public workshop sponsored by the American Association of Tissue Banks (AATB) held to discuss West Nile Virus (WNV) and scientific considerations for tissue donors. The daylong workshop was held 9 July 2010 at the Ritz-Carlton Hotel at Tyson's Corner in McLean, Virginia, United States (U.S.). The workshop was designed to determine and discuss scientific information that is known, and what is not known, regarding WNV infection and transmission. The goal is to determine how to fill gaps in knowledge of WNV and tissue donation and transplantation by pursuing relevant scientific studies. This information should ultimately support decisions leading to appropriate tissue donor screening and testing considerations. Discussion topics were related to identifying these gaps and determining possible solutions. Workshop participants included subject-matter experts from the U.S. Food and Drug Administration, the Centers for Disease Control and Prevention, U.S. Department of Health and Human Services, Health Canada, the Public Health Agency of Canada, AATB-accredited tissue banks including reproductive tissue banks, accredited eye banks of the Eye Bank Association of America, testing laboratories, and infectious disease and organ transplantation professionals. After all presentations concluded, a panel addressed this question: "What are the scientific considerations for tissue donors and what research could be performed to address those considerations?" The slide presentations from the workshop are available at: http://www.aatb.org/2010-West-Nile-Virus-Workshop-Presentations.
Odunayo, Adesola; Garraway, Kayode; Rohrbach, Barton W; Rainey, Amanda; Stokes, Jennifer
2017-02-01
OBJECTIVE To determine the incidence of incompatible crossmatch results in dogs without a history of prior RBC transfusion and to evaluate changes in Hct following RBC administration for transfusion-naïve dogs that did and did not have crossmatching performed. DESIGN Retrospective study. ANIMALS 169 client-owned dogs. PROCEDURES Information obtained from the medical records included signalment, pretransfusion Hct or PCV, and crossmatching results where applicable. Dogs that underwent major crossmatching (n = 149) as part of pretransfusion screening were each crossmatched with 3 potential donors. Donor blood was obtained from a commercial source and tested negative for dog erythrocyte antigens (DEAs) 1.1, 1.2, and 7 but positive for DEA 4. Mean change in Hct after transfusion was compared between crossmatch-tested dogs (57/91 that subsequently underwent RBC transfusion) and 20 other dogs that underwent RBC transfusion without prior crossmatching by statistical methods. RESULTS 25 of 149 (17%) dogs evaluated by crossmatching were incompatible with 1 or 2 of the 3 potential donors. All 149 dogs were compatible with ≥ 1 potential donor. Mean ± SD change in Hct after transfusion was significantly higher in dogs that had crossmatching performed (12.5 ± 8.6%) than in dogs that did not undergo crossmatching (9.0 ± 4.3%). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated immunologic incompatibility can exist between first-time transfusion recipients and potential blood donor dogs. The clinical importance of these findings could not be evaluated, but considering the potential for immediate or delayed hemolytic transfusion reactions or shortened RBC life span, the authors suggest veterinarians consider crossmatching all dogs prior to transfusion when possible.
Lack of KIs virus DNA in plasma and cerebrospinal fluid in Italy.
Macera, Lisa; Focosi, Daniele; Manzin, Aldo; Ceccherini Nelli, Luca; Pistello, Mauro; Maggi, Fabrizio
2015-10-01
Dear Sirs, Satoh et al. recently screened 516 Japanese blood donors with PCR using primers constructed from the consensus domain of the helicase of positive-stranded RNA viruses. They reported a novel enveloped virus with a circular double-stranded DNA genome (tentatively named KIs virus, KIs-V) (Satoh et al., 2011) occurring in 36 out of the 100 hepatitis E (HEV) antibody-positive donors with elevated alanine aminotransferase (ALT) levels (>60 IU/L). More recently, Biagini et al. failed to find KIs-V in plasma from 576 French blood donors with unknown HEV serostatus and unknown ALT values (Biagini et al., 2012). Based on an HEV seroprevalence of 3-52% in France, the authors suggested an uncommon frequency of KIs-V infection in healthy persons in France. To date, no information has been available on the prevalence of KIs-V DNA in Italy. In the present paper, we analyzed KIs-V in 242 plasma samples of blood donors, transplant recipients, and patients with chronic viral infections, and in 52 cerebrospinal fluid (CSF) samples of patients with different neurological disorders. Informed consent was obtained from all patients and the study was performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its amendments. Viral DNA extraction was carried out on 200 μl of plasma or 200 μl of CSF by using QIAamp DNA blood kit (Qiagen, Hilden, Germany) according to the manufacturer's instructions. Extracted nucleic acids were amplified for KIs-V DNA with the nested PCR protocol developed by Satoh et al. (2011) and used for screening Japanese blood donors. The first and second PCR rounds were designed on 458 and 304 nt-length fragments, respectively. To validate the amplification process, positive controls obtained from plasma dilutions of a synthetic template corresponding to the target sequence were run in each PCR. PCR sensitivity was less than 5 copies of target sequence. Fourteen liver and 16 kidney and/or pancreas transplant recipients were tested before transplantation and at the time after transplantation when viremia levels of TTV were highest, TTV having been validated by our group and others as a marker of functional immune deficiency (Focosi et al., 2014). None of the samples tested positive for KIs-V. At the same time, we also tested 79 healthy blood donors. Since determination of ALT is a mandatory part of on blood donation according to Italian law we could establish that only 2 donors had ALT values >60 IU/L but in any case <80 IU/L: all of them tested negative for KIs-V. No information on HEV status was available and HEV seroprevalence studies are limited in Italy (Arends et al., 2014). However regional studies show prevalences ranging from 2.9% to 8.8% (Masia et al., 2009). We also tested 50 HIV-positive patients, 41 HCV-positive patients, and 42 HBV-positive patients. None of the samples tested positive for KIs-V. Finally, cerebrospinal fluid from 52 patients with different neurological disorders was also tested. All these samples were negative for KIs-V DNA. Thus, although we cannot rule out the possibility that KIs-V circulates in Italy at a very low level and genetically different from the virus found in Japanese population, the results seem to demonstrate a very low prevalence of this novel virus in the Italian population. While the implication of KIs-V in human health remains under debate, extensive regional surveys will help to elucidate the geographical spread of KIs-V and to understand the natural history of the infection in human beings.
Steele, Whitney R; High, Patrick M; Schreiber, George B
2012-06-01
Misperceptions about the risk of contracting AIDS from donating blood may be preventing people from donating, while incorrect beliefs about AIDS screening tests or the appropriateness of donating with risk factors may place the blood supply at increased risk. Questions about AIDS transmission and testing and the acceptability of test seeking and donating with risk factors were asked in the National Community Health Survey, a telephone survey of 9859 US adults. Results were weighted to represent the US population. Demographic and donor status (current, lapsed, never) differences in knowledge and attitudes were examined using chi-square and logistic regression. Nearly 25% of respondents thought it was somewhat or very likely that they could get AIDS from donating blood. Almost 80% knew that all blood donations are tested for AIDS, but only 65.5% knew about the test window period. A total of 33.5% felt that it was acceptable to use the blood center for AIDS testing, while 9.1% believed that it was okay for someone to donate even if they had AIDS risk behaviors; all had significant demographic and donor status differences. While there are many factors that prevent people from giving blood, the incorrect belief that it is possible to contract AIDS from donating is likely a barrier to donation. If blood centers dispelled this myth among those who have never donated, especially among minorities, it could be important for recruitment. In addition, our findings indicate that changes to education or recruitment could be needed to discourage test seeking and donations from risky donors. © 2011 American Association of Blood Banks.
New Technologies Extend the Reach of Many College Fund Raisers.
ERIC Educational Resources Information Center
Nicklin, Julie L.
1992-01-01
Increasingly, colleges are using new technologies, often expensive, to improve fund-raising capacity among small-scale donors. Techniques include computerized screening of prospective donors based on personal information, automatic dialing and phone-bank worker training, and sophisticated direct-mail tactics. Concern about privacy and loss of the…
Ruggeri, Annalisa; Rocha, Vanderson; Masson, Emeline; Labopin, Myriam; Cunha, Renato; Absi, Lena; Boudifa, Ali; Coeffic, Brigitte; Devys, Anne; De Matteis, Muriel; Dubois, Valérie; Hanau, Daniel; Hau, Françoise; Jollet, Isabelle; Masson, Dominique; Pedron, Beatrice; Perrier, Pascale; Picard, Christophe; Ramouneau-Pigot, Annie; Volt, Fernanda; Charron, Dominique; Gluckman, Eliane; Loiseau, Pascale
2013-07-01
Graft failure is a major complication after unrelated cord blood transplantation. Presence of HLA-antibodies before cord blood transplantation may impact graft failure. To analyze the effect of anti-HLA antibodies on unrelated cord blood transplantation outcomes, we analyzed 294 unrelated cord blood transplant recipients after reduced intensity conditioning regimen. The majority of the patients (82%) were transplanted for malignancies, 60% with double-unrelated cord blood transplant, 63% were HLA mismatched. Retrospectively, pre-unrelated cord blood transplant serum was tested for HLA-Ab using Luminex™ platform. Results were interpreted as mean fluorescence intensity (MFI) against donor-specific mismatch. Among 62 recipients (23%) who had anti-HLA antibodies before unrelated cord blood transplant, 14 patients had donor specific anti-HLA antibodies (DSA) (7 were donor-specific anti-HLA antibodies for single unrelated cord blood transplant and 7 for double unrelated cord blood transplant). Donor specific anti-HLA antibodies threshold ranged from 1620-17629 of mean fluorescence intensity (MFI). Cumulative incidence of Day-60 neutrophil engraftment was 76%: 44% for recipients with donor specific anti-HLA antibodies and 81% in those without donor specific anti-HLA antibodies (P=0.006). The cumulative incidence of 1-year transplant related mortality was 46% in patients with donor specific anti-HLA antibodies and 32% in those without antibodies (P=0.06). The presence of donor specific anti-HLA antibodies was associated with a trend for decreased survival rate (42% vs. 29%; P=0.07). Donor specific anti-HLA antibody in recipients of unrelated cord blood transplant is associated with graft failure and decreased survival. Patient's screening for donor specific anti-HLA antibodies before unrelated cord blood transplantation is recommended before choosing an HLA mismatched cord blood unit. Whenever possible it is important to avoid selecting a unit for which the patient has donor specific anti-HLA antibodies.
Ureaplasma Transmitted From Donor Lungs Is Pathogenic After Lung Transplantation.
Fernandez, Ramiro; Ratliff, Amy; Crabb, Donna; Waites, Ken B; Bharat, Ankit
2017-02-01
Hyperammonemia is a highly fatal syndrome in lung recipients that is usually refractory to medical therapy. We recently reported that infection by a Mollicute, Ureaplasma, is causative for hyperammonemia and can be successfully treated with antimicrobial agents. However, it remains unknown whether the pathogenic strain of Ureaplasma is donor or recipient derived. Here we provide evidence that donor-derived Ureaplasma infection can be pathogenic. As such, we uncover a previously unknown lethal donor-derived opportunistic infection in lung recipients. Given the high mortality associated with hyperammonemia, strategies for routine donor screening or prophylaxis should be further evaluated in prospective studies. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Vollmer, Tanja; Diekmann, Juergen; Eberhardt, Matthias; Knabbe, Cornelius; Dreier, Jens
2016-09-01
Asymptomatic hepatitis E virus (HEV) infections have been found in blood donors from various European countries, but the natural course is rarely specified. Here, we compared the progression of HEV viraemia, serostatus and liver-specific enzymes in 10 blood donors with clinically asymptomatic genotype 3 HEV infection, measuring HEV RNA concentrations, plasma concentrations of alanine/aspartate aminotransferase, glutamate dehydrogenase and bilirubin and anti-HEV IgA, IgM and IgG antibodies. RNA concentrations ranged from 77.2 to 2.19×10(5) IU/mL, with viraemia lasting from less than 10 to 52 days. Donors showed a typical progression of a recent HEV infection but differed in the first detection of anti-HEV IgA, IgM and IgG and seropositivity of the antibody classes. The diagnostic window between HEV RNA detection and first occurrence of anti-HEV antibodies ranged from eight to 48 days, depending on the serological assay used. The progression of laboratory parameters of asymptomatic HEV infection was largely comparable to the progression of symptomatic HEV infection, but only four of 10 donors showed elevated liver-specific parameters. Our results help elucidate the risk of transfusion-associated HEV infection and provide a basis for development of screening strategies. The diagnostic window illustrates that infectious blood donors can be efficiently identified only by RNA screening. This article is copyright of The Authors, 2016.
Zheng, Xiaofan; Ding, Wei; Li, Gan; Wu, Yaling; Wu, Danxiao; Zhu, Hong; He, Ji; Wang, Bin; Zhao, Longyou; Zhu, Faming; Lv, Hangjun
2015-01-01
Background The high prevalence of hepatitis B and C viruses (HBV and HCV), paralleling the growing epidemic of human immunodeficiency virus (HIV) and Treponema pallidum (TP) infections in the general population, poses a great threat to blood safety in China. This study investigated the prevalence of serological markers for causative agents of transfusion-transmissible infections (TTI), i.e. HBV, HCV, HIV and TP, among volunteer blood donors in five cities/regions of Zhejiang Province, China. Material and methods We investigated whole blood and apheresis donations collected at the Blood Services in five cities/regions in Zhejiang Province between January 1, 2006 and December 31, 2012. Two rounds of serological testing were performed for HBsAg, anti-HCV, anti-HIV1/2 and anti-TP using different kits. The rates of serological positivity were calculated and further analysis was performed to examine the association between donors’ characteristics and seroprevalence. Results Of the 1,615,120 donations, approximately 40% came from first-time donors and 60% from repeat donors. The overall seroprevalence rates of HBV, HCV, HIV and TP were 0.51%, 0.25%, 0.15% and 0.52%, respectively. The overall prevalences of HCV and HIV remained relatively steady, whereas the prevalence of TP increased sharply after 2010. However, the prevalence of TTI agents varied among volunteer blood donors in different cities/regionsand demographic groups. Discussion We collected data on the seroprevalence of TTI agents among volunteer blood donors. Although the risk of TTI is low in China compared to that in some developing countries, sensitive screening methods and recruitment of regular donors are still very important for blood safety and availability. PMID:26192780
Salunkhe, Vishal; van der Meer, Pieter F; de Korte, Dirk; Seghatchian, Jerard; Gutiérrez, Laura
2015-02-01
Transfusion-transmitted infections (TTI) have been greatly reduced in numbers due to the strict donor selection and screening procedures, i.e. the availability of technologies to test donors for endemic infections, and routine vigilance of regulatory authorities in every step of the blood supply chain (collection, processing and storage). However, safety improvement is still a matter of concern because infection zero-risk in transfusion medicine is non-existent. Alternatives are required to assure the safety of the transfusion product and to provide a substitution to systematic blood screening tests, especially in less-developed countries or at the war-field. Furthermore, the increasing mobility of the population due to traveling poses a new challenge in the endemic screening tests routinely used, because non-endemic pathogens might emerge in a specific population. Pathogen reduction treatments sum a plethora of active approaches to eliminate or reduce potential threatening pathogen load from blood transfusion products. Despite the success of pathogen reduction treatments applied to plasma products, there is still a long way to develop and deploy pathogen reduction treatments to cellular transfusion products (such as platelets, RBCs or even to whole blood) and there is divergence on its acceptance worldwide. While the use of pathogen reduction treatments in platelets is performed routinely in a fair number of European blood banks, most of these treatments are not (or just) licensed in the USA or elsewhere in the world. The development of pathogen reduction treatments for RBC and whole blood is still in its infancy and under clinical trials. In this review, we discuss the available and emerging pathogen reduction treatments and their advantages and disadvantages. Furthermore, we highlight the importance of characterizing standard transfusion products with current and emerging approaches (OMICS) and clinical outcome, and integrating this information on a database, thinking on the benefits it might bring in the future toward personalized transfusion therapies. Copyright © 2014 Elsevier Ltd. All rights reserved.
Yoshida, Naoko; Ye, Lizhen; Liu, Fengmao; Li, Zhiling; Katayama, Arata
2013-02-01
Biodegradable plastics (BPs) were evaluated for their applicability as sustainable and solid H(2) donors for microbial reductive dechlorination of 4,5,6,7-tetrachlorophthalide (fthalide). After a screening test of several BPs, the starch-based plastic (SP) that produced the highest levels of H(2) was selected for its use as the sole H(2) donor in this reaction. Fthalide dechlorination was successfully accomplished by combining an H(2)-producing SP culture and a KFL culture containing Dehalobacter species, supplemented with 0.13% and 0.5% SP, respectively. The efficiency of H(2) use in dechlorination was evaluated in a combined culture containing the KFL culture and strain Clostridium sp. Ma13, a new isolate that produces H(2) from SP. Results obtained with this culture indicated increased H(2)-fraction for fthalide dechlorination much more in this culture than in compared with a KFL culture supplemented with 20mM lactate, which are 0.75 H(2)·glucose(-1) and 0.015 H(2)·lactate(-1) in mol ratio, respectively. Copyright © 2012 Elsevier Ltd. All rights reserved.
Seroprevalence of Fecal-Oral Transmitted Hepatitis A and E Virus Antibodies in Burkina Faso
Traoré, Kuan Abdoulaye; Rouamba, Hortense; Nébié, Yacouba; Sanou, Mahamadou; Traoré, Alfred S.
2012-01-01
Hepatitis A virus (HAV) and hepatitis E virus (HEV) infections occur chiefly as a result of unhygienic conditions. The purpose of this study was to assess the seroprevalence of antibodies to both viruses in central Burkina Faso in the absence of a recorded hepatitis epidemic. Serum samples from 178 blood donors (131 males and 47 females) and from 189 pregnant women were collected from November 2010 to March 2012, at blood banks and medical centers in Burkina Faso. An immunochromatography test was used to screen for Anti-HAV IgM and IgG in a subgroup of 91 blood donors and 100 pregnant women. The seroprevalence of anti-HAV IgG was 14.3% [CI95, 7.1–21.4%] for all blood donors and 23% [CI95, 14.8–31.2%] for pregnant women. Anti-HEV IgG were detected using the ELISA kits Dia.pro and Wantai and were found in 19.1% [CI95, 13.3–24.9%] of the blood donors and 11.6% [CI95, 7.1–16.2%] of the pregnant women. The seroprevalences of anti-HAV and anti-HEV IgGs did not differ significantly between men and women blood donors. Anti-HAV IgM was detected in 3.3% of the blood donors and in 2% of the pregnant women. These findings for asymptomatic individuals indicate that the HAV and HEV circulate at low but significant levels. This is the first evaluation of the acute hepatitis virus burden in Burkina Faso and the underlying epidemiologic status of the population. PMID:23110187
Seroprevalence of fecal-oral transmitted hepatitis A and E virus antibodies in Burkina Faso.
Traoré, Kuan Abdoulaye; Rouamba, Hortense; Nébié, Yacouba; Sanou, Mahamadou; Traoré, Alfred S; Barro, Nicolas; Roques, Pierre
2012-01-01
Hepatitis A virus (HAV) and hepatitis E virus (HEV) infections occur chiefly as a result of unhygienic conditions. The purpose of this study was to assess the seroprevalence of antibodies to both viruses in central Burkina Faso in the absence of a recorded hepatitis epidemic. Serum samples from 178 blood donors (131 males and 47 females) and from 189 pregnant women were collected from November 2010 to March 2012, at blood banks and medical centers in Burkina Faso. An immunochromatography test was used to screen for Anti-HAV IgM and IgG in a subgroup of 91 blood donors and 100 pregnant women. The seroprevalence of anti-HAV IgG was 14.3% [CI95, 7.1-21.4%] for all blood donors and 23% [CI95, 14.8-31.2%] for pregnant women. Anti-HEV IgG were detected using the ELISA kits Dia.pro and Wantai and were found in 19.1% [CI95, 13.3-24.9%] of the blood donors and 11.6% [CI95, 7.1-16.2%] of the pregnant women. The seroprevalences of anti-HAV and anti-HEV IgGs did not differ significantly between men and women blood donors. Anti-HAV IgM was detected in 3.3% of the blood donors and in 2% of the pregnant women. These findings for asymptomatic individuals indicate that the HAV and HEV circulate at low but significant levels. This is the first evaluation of the acute hepatitis virus burden in Burkina Faso and the underlying epidemiologic status of the population.
Rosso, Fernando; Pineda, Juan C; Sanz, Ana M; Cedano, Jorge A; Caicedo, Luis A
Dengue fever is a vector-transmitted viral infection. Non-vectorial forms of transmission can occur through organ transplantation. We reviewed medical records of donors and recipients with suspected dengue in the first post-transplant week. We used serologic and molecular analysis to confirm the infection. Herein, we describe four cases of dengue virus transmission through solid organ transplantation. The recipients had positive serology and RT-PCR. Infection in donors was detected through serology. All cases presented with fever within the first week after transplantation. There were no fatal cases. After these cases, we implemented dengue screening with NS1 antigen detection in donors during dengue outbreaks, and no new cases were detected. In the literature review, additional cases had been published through August 2017. Transmission of Dengue virus can occur through organ donation. In endemic regions, it is important to suspect and screen for dengue in febrile and thrombocytopenic recipients in the postoperative period. Copyright © 2018 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.
Schütz, Harald; Auch, Jürgen; Erdmann, Freidoon; Weiler, Günter; Verhoff, Marcel A
2006-01-01
Immunoassays are used worldwide for the rapid screening of drugs. Despite the fact that they are highly valuable tools for the testing of legal and illicit drugs, there is a non-negligable risk of false-positive and false-negative findings and many pitfalls must be taken into account when using these tests in an uncritical manner and without valid confirmation procedures. In order to check the correlation between cloned-enzyme donor immunoassay (CEDIA) readings and exact determined gas chromatography/mass spectrometry (GC/MS) values for benzoylecgonine, a total of 472 serum samples was measured with an immunoassay (CEDIA) as well as GC/MS. As a result, it was shown that in the lower area of concentration, up to approx. 300 ng equ. benzoylecgonine/ml, there is a semiquantitative useful correlation. With higher concentrations, the values shift more and more apart and many runaways are visible. Generally the use of tests for materials other than those declared is excluded from the manufacturer's warranty and is at the user's own risk, but the authors found that many immunochemical tests with a certification only for the use in urine are well suited to the screening of serum samples, and even low readings could be confirmed by GC/MS. With blood or serum as sample, it could be regularly observed that generally very small readings could not only be confirmed with mass spectrometry but could in most cases also be quantified. This was the key factor in determining the rate of confirmation in 495 cases. In total, an incredibly high reliability for the CEDIA cocaine test (via benzoylecgonine) was shown up to the area of detection (detection limit), far below the cut-off. These results confirm the extraordinary sensitivity and specificity of this test also for blood or serum as sample material to be tested.
Evaluation of a new automated instrument for pretransfusion testing.
Morelati, F; Revelli, N; Maffei, L M; Poretti, M; Santoro, C; Parravicini, A; Rebulla, P; Cole, R; Sirchia, G
1998-10-01
A number of automated devices for pretransfusion testing have recently become available. This study evaluated a fully automated device based on column agglutination technology (AutoVue System, Ortho, Raritan, NJ). Some 6747 tests including forward and reverse ABO group, Rh type and phenotype, antibody screen, autocontrol, and crossmatch were performed on random samples from 1069 blood donors, 2063 patients, and 98 newborns and cord blood. Also tested were samples from 168 immunized patients and 53 donors expressing weak or variant A and D antigens. Test results and technician times required for their performance were compared with those obtained by standard methods (manual column agglutination technology, slide, semiautomatic handler). No erroneous conclusions were found in regard to the 5028 ABO group and Rh type or phenotype determinations carried out with the device. The device rejected 1.53 percent of tests for sample inadequacy. Of the remaining 18 tests with discrepant results found with the device and not confirmed with the standard methods, 6 gave such results because of mixed-field reactions, 10 gave negative results with A2 RBCs in reverse ABO grouping, and 2 gave very weak positive reactions in antibody screening and crossmatching. In the samples from immunized patients, the device missed one weak anti-K, whereas standard methods missed five weak antibodies. In addition, 48, 34, and 31 of the 53 weak or variant antigens were detected by the device, the slide method, and the semiautomated handler, respectively. Technician time with the standard methods was 1.6 to 7 times higher than that with the device. The technical performance of the device compared favorably with that of standard methods, with a number of advantages, including in particular the saving of technician time. Sample inadequacy was the most common cause of discrepancy, which suggests that standardization of sample collection can further improve the performance of the device.
Glycan microarray screening assay for glycosyltransferase specificities.
Peng, Wenjie; Nycholat, Corwin M; Razi, Nahid
2013-01-01
Glycan microarrays represent a high-throughput approach to determining the specificity of glycan-binding proteins against a large set of glycans in a single format. This chapter describes the use of a glycan microarray platform for evaluating the activity and substrate specificity of glycosyltransferases (GTs). The methodology allows simultaneous screening of hundreds of immobilized glycan acceptor substrates by in situ incubation of a GT and its appropriate donor substrate on the microarray surface. Using biotin-conjugated donor substrate enables direct detection of the incorporated sugar residues on acceptor substrates on the array. In addition, the feasibility of the method has been validated using label-free donor substrate combined with lectin-based detection of product to assess enzyme activity. Here, we describe the application of both procedures to assess the specificity of a recombinant human α2-6 sialyltransferase. This technique is readily adaptable to studying other glycosyltransferases.
Owusu-Ofori, Alex; Gadzo, Dominic; Bates, Imelda
2016-04-23
Transfusion-transmitted malaria (TTM) is a risk of transfusion that has not been well described in malaria endemic regions. The risk of the recipient getting malaria is related to the prevalence of malaria in the blood donors. There is however little information on the prevalence of malaria among donors in Akatsi district of Ghana. Further, the knowledge and practices of healthcare workers to TTM is unknown. The study was undertaken to determine the prevalence of malaria parasite infection among blood donors and to evaluate the knowledge and practices of healthcare workers to TTM in the Akatsi district of Ghana. The study was conducted at Akatsi South District Hospital between May and August 2014. To screen for Plasmodium falciparum, 5 µl of capillary blood was obtained by finger prick from 200 participants (100 donors and 100 healthy controls). Plasmodium falciparum screening was done using CareStart™ Malaria Antigen kit. To obtain information regarding TTM knowledge and practices, questionnaires were completed by 100 health workers including nurses, doctors and laboratory staff. The prevalence of P. falciparum was the same (10 %) in both donors and controls. All those who were malaria RDT positive were aged 15-25 years. Out of the 100 healthcare workers (31 males and 69 females) surveyed, 45 % of respondents (45/100) had never heard of transfusion-transmitted malaria. Almost all respondents (91 %) had not attended any lecture/seminar/workshop on blood transfusion in the past 12 months. There were 44 respondents (44 %) who wrongly said malaria was being screened for prior to transfusion in their hospital. However, 98.2 % (54/55) of those who had heard about TTM rightly stated that TTM can be prevented. The prevalence of P. falciparum parasitaemia is 10 % in healthy blood donors in the Akatsi district and represents a risk for TTM though the extent of this risk is unclear. Knowledge about TTM in healthcare workers in the district is low. Continuous education and in-service training may be a means to improve TTM knowledge and preventive practices by the health workers in the district.
Use of computed tomography renal angiography for screening feline renal transplant donors.
Bouma, Jennifer L; Aronson, Lillian R; Keith, Dennis G; Saunders, H Mark
2003-01-01
Preoperative knowledge of the renal vascular anatomy is important for selection of the appropriate feline renal donor. Intravenous urograms (IVUs) have been performed routinely to screen potential donors at the Veterinary Hospital of the University of Pennsylvania (VHUP), but the vascular phase views lack sufficient detail of the renal vascular anatomy. Computed tomography angiography (CTA), which requires a helical computed tomography (CT) scanner, has been found to provide superior renal vascular anatomic information of prospective human renal donors. The specific aims of this study were as follows: 1) develop the CTA technique for the feline patient; and 2) obtain preliminary information on feline renal vessel anatomy in potential renal donors. Ten healthy, potential feline renal donors were anesthetized and imaged using a third-generation helical CT scanner. The time delay between i.v. contrast medium injection and image acquisition, and other parameters of slice collimation, slice interval, pitch, exposure settings, and reconstruction algorithms were varied to maximize contrast medium opacification of the renal vascular anatomy. Optimal CTA acquisition parameters were determined to be: 1) 10-sec delay post-i.v. bolus of iodinated contrast medium; 2) two serially acquired (corresponding to arterial and venous phases) helical scans through the renal vasculature; 3) pitch of 2 (4 mm/sec patient translation, 2 mm slice collimation); and 4) 120-kVp, 160-mA, and 1-sec exposure settings. Retrospective reconstructed CTA transverse images obtained at a 2-mm slice width and a 1-mm slice interval in combination with two-dimensional reformatted images and three-dimensional reconstructed images were qualitatively evaluated for vascular anatomy; vascular anatomy was confirmed at surgery. Four cats had single renal arteries and veins bilaterally; four cats had double renal veins. One cat had a small accessory artery supplying the caudal pole of the left kidney. One cat had a left renal artery originating from the aorta at a 90 degrees angle with the cranial mesenteric artery. CTA of the feline renal vascular anatomy is feasible, and reconstruction techniques provide excellent anatomic vascular detail. CTA is now used routinely at VHUP to screen all potential feline renal donors.
Investigational Testing for Zika Virus among U.S. Blood Donors.
Saá, Paula; Proctor, Melanie; Foster, Gregory; Krysztof, David; Winton, Colleen; Linnen, Jeffrey M; Gao, Kui; Brodsky, Jaye P; Limberger, Ronald J; Dodd, Roger Y; Stramer, Susan L
2018-05-10
Because of the potential severe clinical consequences of Zika virus (ZIKV) infection, the large numbers of asymptomatic travelers returning from ZIKV-active areas, the detection of ZIKV nucleic acid in blood, and reports of transmission of ZIKV through transfusion, in 2016 the Food and Drug Administration released recommendations for individual-unit nucleic acid testing to minimize the risk of transmission of ZIKV through blood transfusions. The American Red Cross implemented investigational screening of donated blood for ZIKV RNA by means of transcription-mediated amplification (TMA). Confirmatory testing of reactive donations involved repeat TMA, TMA testing in exploratory minipools, real-time reverse-transcriptase polymerase chain reaction, IgM serologic testing, and red-cell TMA. Viral loads in plasma and red cells were estimated by means of end-point TMA. The costs of interdicting a donation that was confirmed to be positive were calculated for the 15-month period between June 2016 and September 2017. Of the 4,325,889 donations that were screened, 393,713 (9%) were initially tested in 24,611 minipools, and no reactive donations were found. Of the 3,932,176 donations that were subsequently tested individually, 160 were initially reactive and 9 were confirmed positive (a 1:480,654 confirmed-positive rate overall; positive predictive value, 5.6%; specificity, 99.997%). Six (67%) of the confirmed-positive donations were reactive on repeat TMA, of which 4 were IgM-negative; of these 4, all 3 that could be tested were reactive on minipool TMA. Two confirmed-positive donors had infections that had been transmitted locally (in Florida), 6 had traveled to ZIKV-active areas, and 1 had received an experimental ZIKV vaccine. ZIKV RNA levels in red cells ranged from 40 to 800,000 copies per milliliter and were detected up to 154 days after donation, as compared with 80 days of detection in plasma at levels of 12 to 20,000 copies per milliliter. On the basis of industry-reported costs of testing and the yield of the tests in our study, the cost of identifying 8 mosquito-borne ZIKV infections through individual-unit nucleic acid testing was $5.3 million per ZIKV RNA-positive donation. Screening of U.S. blood donations for ZIKV by individual-donation TMA was costly and had a low yield. Among the 9 confirmed ZIKV-positive donations, only 4 were IgM-negative; of these donations, all 3 that were tested were reactive on minipool TMA. (Funded by the American Red Cross and Grifols Diagnostic Solutions.).
Reiche, Edna Maria Vissoci; Vogler, Ingridt Hildegard; Morimoto, Helena Kaminami; Bortoliero, André Luis; Matsuo, Tiemi; Yuahasi, Kátia Kioko; Cancian, Sanderson Júnior; Koguichi, Roberto Setsuo
2003-01-01
This study evaluated the usefulness of the anti-HBc, hepatitis C virus antibodies (anti-HCV), human T cell lymphotropic virus I and II antibodies (anti-HTLV I/II), serologic tests for syphilis, and surface antigen of hepatitis B virus (HBsAg) as surrogate markers for the risk for HIV infection in 80,284 serum samples from blood donors from the Blood Bank of "Hospital Universitário Regional Norte do Paraná", Londrina, Paraná State, Brazil, analyzed from July 1994 to April 2001. Among 39 blood donors with positive serology for HIV, 12 (30.8%) were anti-HBc positive, 10 (25.6%) for anti-HCV, 1 (2.6%) for anti-HTLV I/I, 1 (2.6%) was positive for syphilis, and 1 (2.6%) for HBsAg. Among the donors with negative serology for HIV, these markers were detected in 8,407 (10.5%), 441 (0.5%), 189 (0.2%), 464 (0.6%), and 473 (0.6%) samples, respectively. The difference was statistically significant (p < 0.001) for anti-HBc and anti-HCV. Although the predictive positive values for these surrogate markers were low for HIV infection, the results confirmed the anti-HBc and anti-HCV as useful surrogate markers for HIV infection thus reinforcing the maintenance of them in the screening for blood donors contributing to the prevention of the small number of cases in which HIV is still transmitted by transfusion.
Hepatitis G virus (HGV) infection in voluntary and commercial blood donors in India.
Kar, P; Bedi, P; Berry, N; Chakravorty, A; Gupta, R K; Saha, R; Das, B C
2000-09-01
The prevalence of hepatitis G virus (HGV) has been determined in commercial as well as voluntary blood donors from India by detecting viral RNA genome using reverse transcription polymerase chain reaction (RT-PCR) assay. 45 professional blood donors from private blood banks and 50 healthy controls who opted for voluntary blood donation were recruited for the study. Both the groups were also screened serologically for HBV and HCV infection. The prevalence of HGV in the general population in India was found to be 4% but significantly a higher frequency (46.6%; p<0.001) of HGV was observed in commercial blood donors.
Evolutionary transgenomics: prospects and challenges.
Correa, Raul; Baum, David A
2015-01-01
Many advances in our understanding of the genetic basis of species differences have arisen from transformation experiments, which allow us to study the effect of genes from one species (the donor) when placed in the genetic background of another species (the recipient). Such interspecies transformation experiments are usually focused on candidate genes - genes that, based on work in model systems, are suspected to be responsible for certain phenotypic differences between the donor and recipient species. We suggest that the high efficiency of transformation in a few plant species, most notably Arabidopsis thaliana, combined with the small size of typical plant genes and their cis-regulatory regions allow implementation of a screening strategy that does not depend upon a priori candidate gene identification. This approach, transgenomics, entails moving many large genomic inserts of a donor species into the wild type background of a recipient species and then screening for dominant phenotypic effects. As a proof of concept, we recently conducted a transgenomic screen that analyzed more than 1100 random, large genomic inserts of the Alabama gladecress Leavenworthia alabamica for dominant phenotypic effects in the A. thaliana background. This screen identified one insert that shortens fruit and decreases A. thaliana fertility. In this paper we discuss the principles of transgenomic screens and suggest methods to help minimize the frequencies of false positive and false negative results. We argue that, because transgenomics avoids committing in advance to candidate genes it has the potential to help us identify truly novel genes or cryptic functions of known genes. Given the valuable knowledge that is likely to be gained, we believe the time is ripe for the plant evolutionary community to invest in transgenomic screens, at least in the mustard family Brassicaceae where many species are amenable to efficient transformation.
Wiegand, J; Luz, B; Mengelkamp, A-K; Moog, R; Koscielny, J; Halm-Heinrich, I; Susemihl, C; Bentzien, F; Diekmann, J; Wernet, D; Karger, R; Angert, K; Schmitt-Thomssen, A; Kiefel, V; Lutter, K; Hesse, R; Kätzel, R; Opitz, A; Luhm, J; Barz, D; Leib, U; Matthes, G; Tillmann, H L
2009-10-01
Prevalence data concerning viral hepatitis and human immunodeficiency virus (HIV) in the general population are usually scarce. We aimed for a large cohort representative of the general population that required little funding. Autologous blood donors are relatively representative of the general population, and are tested for viral hepatitis and HIV in many countries. However, frequently these data are not captured for epidemiologic purposes. We analysed data from well over 35,000 autologous blood donors as recorded in 21 different transfusion centres for anti-hepatitis C virus (HCV), HBsAg and anti-HIV, as well as TPHA if available. We found a lower prevalence of hepatitis B virus and HCV in East vs West Germany, 0.2%vs 0.32% and 0.16%vs 0.32% respectively, which confirms earlier data in smaller cohorts, thus supporting the value of our approach. HIV was too rare to disclose significant differences, 0.01%vs 0.02%. TPHA was higher in East (0.34%) vs West Germany (0.29%) without significant differences. HCV was more frequent in women vs men. Transfusion institutes managing autologous blood donations should be used as a resource for epidemiological data relating to viral hepatitis and HIV, if such testing is performed routinely. This approach generates data relating to the general population with special emphasis on undiagnosed cases.
Should living kidney donor candidates with impaired fasting glucose donate?
Vigneault, Christine Buchek; Asch, William Stuart; Dahl, Neera Kanhouwa; Bia, Margaret Johnson
2011-08-01
As the kidney transplant waiting list grows, the willingness of transplant centers to accept complex donors increases. Guidelines for the evaluation of living kidney donors exist but do not provide clear guidance when evaluating the complex donor. Although few transplant centers will approve donor candidates with impaired glucose tolerance and most, if not all, will deny candidates with diabetes, many will approve candidates with impaired fasting glucose (IFG). Furthermore, the demographic of living donors has changed in the past 10 years to increasingly include more nonwhite and Hispanic individuals who are at greater risk for future diabetes and hypertension. IFG may be more of a concern in potential donors whose nonwhite and Hispanic ethnicity already places them at greater risk. We review the definition of diabetes, diabetes prediction tools, and transplant guidelines for donor screening and exclusion as it pertains to impaired glucose metabolism, and additional ethnic and nonethnic factors to consider. We offer an algorithm to aid in evaluation of potential living donors with IFG in which ethnicity, age, and features of the metabolic syndrome play a role in the decision making.
Fear of blood draws, vasovagal reactions, and retention among high school donors.
France, Christopher R; France, Janis L; Carlson, Bruce W; Himawan, Lina K; Stephens, Kirsten Yunuba; Frame-Brown, Terri A; Venable, Geri A; Menitove, Jay E
2014-03-01
We previously demonstrated that fear of having blood drawn is one of the strongest known predictors of vasovagal reactions among high school blood donors. This report examines the combined effects of donor fear and experience of vasovagal reactions on repeat donation attempts among high school blood donors. Immediately after completing the blood donor health screening, 1715 high school students were asked about their fear of having blood drawn. The donor record was then used to collect information regarding their experience of vasovagal reactions at the time of donation as well as their subsequent donation attempts within the following year. Fear of having blood drawn and the experience of a vasovagal reaction each contributed to donor attrition, with only 33.2% of fearful donors who experienced a vasovagal reaction returning in the following year compared to 56.7% of nonfearful nonreactors. Path analyses demonstrated that fear has an indirect effect (through vasovagal reactions) on repeat donations among first-time donors and both direct and indirect effects on repeat donation attempts among experienced donors. Among high school blood donors, fear of having blood drawn has both a direct negative effect on donor retention and an indirect negative effect by increasing the risk of vasovagal reactions. Accordingly, targeted efforts to reduce donor fear may be particularly efficient in promoting long-term donor loyalty among our youngest donors. © 2013 American Association of Blood Banks.
Evaluation of Kidney Donors: Core Curriculum 2018.
Sawinski, Deirdre; Locke, Jayme E
2018-05-01
Nearly 100,000 patients are waiting for a kidney transplant, yet each year only 11,000 undergo transplantation with a deceased donor kidney. Annual death rates among waitlist registrants range from 5% to 15%; many die before receiving a transplant. Not surprisingly, registrants turn to family and friends to become living kidney donors on their behalf. Living kidney donor selection practices aim to quantify lifetime risk for kidney failure based on a candidate's predonation demographic and health characteristics. It has been established that estimated lifetime risk for kidney failure varies considerably based on predonation comorbid conditions, and as such, it is of paramount importance that potential living donor candidates undergo proper medical, surgical, and psychosocial screening before donation. This installment of AJKD's Core Curriculum in Nephrology provides readers with the tools necessary for proper evaluation of living kidney donor candidates. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
St. Louis encephalitis virus possibly transmitted through blood transfusion-Arizona, 2015.
Venkat, Heather; Adams, Laura; Sunenshine, Rebecca; Krow-Lucal, Elisabeth; Levy, Craig; Kafenbaum, Tammy; Sylvester, Tammy; Smith, Kirk; Townsend, John; Dosmann, Melissa; Kamel, Hany; Patron, Roberto; Kuehnert, Matthew; Annambhotla, Pallavi; Basavaraju, Sridhar V; Rabe, Ingrid B
2017-12-01
St. Louis encephalitis virus is a mosquito-borne flavivirus that infrequently causes epidemic central nervous system infections. In the United States, blood donors are not screened for St. Louis encephalitis virus infection, and transmission through blood transfusion has not been reported. During September 2015, St. Louis encephalitis virus infection was confirmed in an Arizona kidney transplant recipient. An investigation was initiated to determine the infection source. The patient was interviewed, and medical records were reviewed. To determine the likelihood of mosquito-borne infection, mosquito surveillance data collected at patient and blood donor residences in timeframes consistent with their possible exposure periods were reviewed. To investigate other routes of exposure, organ and blood donor and recipient specimens were obtained and tested for evidence of St. Louis encephalitis virus infection. The patient presented with symptoms of central nervous system infection. Recent St. Louis encephalitis virus infection was serologically confirmed. The organ donor and three other organ recipients showed no laboratory or clinical evidence of St. Louis encephalitis virus infection. Among four donors of blood products received by the patient via transfusion, one donor had a serologically confirmed, recent St. Louis encephalitis virus infection. Exposure to an infected mosquito was unlikely based on the patient's minimal outdoor exposure. In addition, no St. Louis encephalitis virus-infected mosquito pools were identified around the patient's residence. This investigation provides evidence of the first reported possible case of St. Louis encephalitis virus transmission through blood product transfusion. Health care providers and public health professionals should maintain heightened awareness for St. Louis encephalitis virus transmission through blood transfusion in settings where outbreaks are identified. © 2017 AABB.
Tran, Sheri; Lewalski, Eva A.; Dwyre, Denis M.; Hagar, Yolanda; Beckett, Laurel; Janatpour, Kim A.; Holland, Paul V.
2009-01-01
Background and Objectives Emergency situations often elicit a generous response from the public. This occurred after attacks on the US on September 11, 2001 when many new blood donors lined up to donate. This study was performed to compare return rates for first time donors (FTD) after September 11th, 2001 to FTD during a comparable period in 2000. Materials and Methods 3315 allogeneic whole blood donations from FTD at a regional blood center were collected between September 11th and 30th, 2001. Subsequent donations by the FTD before March 31, 2002 were reviewed. This (test) group was compared to 1279 FTD(control group) donating during the same time period in September 2000 and to their return rate in the subsequent six months. Results Following September 11, 2001, 1087/3315 (32.8%) FTD returned by March 31, 2002. This return rate was similar to the control group (427/1279 (33.4%)). The deferral rate during the donor screening process for the control group was significantly higher than the deferral rate for the September 11–30, 2001 group (p < 0.01). The odds of an individual FTD returning increased with age, and the chance of a female donor returning was 1.13 times higher than a male (p = 0.06). There was a carryover effect after Sept. 11, 2001 too. Conclusion A national emergency, September 11, 2001, inspired people to donate blood for the first time. However, the proportion of return donations amongst them was not increased. Females and males in certain age groups were more likely to become repeat donors due to the residual effect of September 11, 2001. Additional efforts are needed to retain eligible FTD in donor pools. PMID:20002621
Genetic aspects of artificial insemination with donor semen: the French CECOS Federation guidelines.
Jalbert, P; Leonard, C; Selva, J; David, G
1989-06-01
The genetic problems raised by assisted reproduction using donor gametes (AID) are numerous and often complex. They concern the legitimacy and the appropriate forms of genetic screening for both gamete donors and recipients; the identification of genetic indications justifying the use of this method of reproduction; and ascertainment of the state of health of the conceptus at birth. The experience and guidelines of the French CECOS Federation, which comprises 20 AID treatment centers, are described. The discussion emphasizes the need for an international exchange of view on this subject.
Jacquot, Cyril; Seo, Andrew; Miller, Peter M; Lezama, Niara; Criss, Valli R; Colvin, Camilla; Luban, Naomi L C; Wong, Edward C C
2017-11-01
Directed donation is associated with a higher prevalence of donations that are positive for infectious disease markers; however, little is known about the positive rates among parental-directed, non-parental-directed, and allogeneic donations. We reviewed blood-collection records from January 1997 through December 2008, including infectious disease results, among parental, non-parental, and community donations. Infectious disease rates were compared by Mann-Whitney U test. In total, 1532 parental, 4910 non-parental, and 17,423 community donations were examined. Among parental donors, the median rate of positive infectious disease testing was 8.66% (interquartile range (IQR), 4.49%) for first-time donors and 1.26% (IQR, 5.86%) for repeat donors; among non-parental donors, the rate was 1.09% (IQR, 0.98%) for first-time donors and 0% (IQR, 0.83%) for repeat donors; and, among community donors, the rate was 2.95% (IQR, 1.50%) for first-time donors and 0.45% (IQR, 0.82%) for repeat donors. The mean rate of positive infectious disease testing for first-time parental donors was significantly higher (7.63%), whereas all repeat donors had similar rates. However, the rate of positive infectious disease testing among first-time non-parental donors was significantly lower than that in the other groups, especially for the period from 2001 through 2008. First-time non-parental and community donors had significantly higher infectious disease risk than the respective repeat donors. First-time parental donors had the highest rates of positive infectious disease testing. We suggest that first-time parental blood donation should be discouraged. Repeat community donors or first-time non-parental donors provide a safer alternative. These findings can foster better patient education, donor selection, and possibly a reduced risk of infectious disease. © 2017 AABB.
Escuder-Vieco, Diana; Garcia-Algar, Óscar; Pichini, Simona; Pacifici, Roberta; García-Lara, Nadia Raquel; Pallás-Alonso, Carmen Rosa
2014-04-01
To validate the health and lifestyle questionnaire answered by donors to a human milk bank with respect to the presence of illegal drugs, nicotine, and caffeine levels in donor milk. A total of 400 human milk samples from 63 donors were analyzed by liquid chromatography tandem mass spectrometry for the presence of 14 illegal drugs, nicotine, and caffeine. Demographics and clinical and lifestyle data (illegal drugs, tobacco, and caffeinated beverage use) were collected from the required screening questionnaire of a human milk bank. The relationship between the 2 evaluation techniques was determined. Illegal drugs were not found in donor milk. Nicotine (46.1 ng/mL) and cotinine (138.6 ng/mL) were quantified in one milk sample from a donor who did not report tobacco use in the questionnaire (1.6% false negative). Caffeine was detected in 45.3% (181/400) of the total milk samples, with a mean concentration of 496 ± 778 ng/mL. The sensitivity and specificity of the questionnaire to detect caffeine in donor milk was 46% and 77%, respectively. The lifestyle questionnaire is reliable for the assessment of illicit drug use by donors to a human milk bank, but there are certain limitations regarding the identification of second-hand smoke exposure and the disclosure of consumption of caffeinated beverages. Data such as smoking habits of partners, type and volume of beverage or food containing caffeine, method of preparation, and time of day of consumption should be collected by the questionnaire. Copyright © 2014 Mosby, Inc. All rights reserved.
Blood transfusion-acquired hemoglobin C.
Suarez, A A; Polski, J M; Grossman, B J; Johnston, M F
1999-07-01
Unexpected and confusing laboratory test results can occur if a blood sample is inadvertently collected following a blood transfusion. A potential for transfusion-acquired hemoglobinopathy exists because heterozygous individuals show no significant abnormalities during the blood donor screening process. Such spurious results are infrequently reported in the medical literature. We report a case of hemoglobin C passively transferred during a red blood cell transfusion. The proper interpretation in our case was assisted by calculations comparing expected hemoglobin C concentration with the measured value. A review of the literature on transfusion-related preanalytic errors is provided.
[Vascular anatomy of donor and recipient in living kidney transplantation].
Zhang, Jiqing; Zhang, Xiaodong
2009-09-01
To review the vascular anatomy of the donor and the recipient for the living kidney transplantation. The recent literature about the vessels of donor and recipient in clinical applications was extensively reviewed. The pertinent vascular anatomy of the donor and recipient was essential for the screening of the proper candidates, surgical planning and long-term outcome. Early branching and accessory renal artery of the donor were particularly important to deciding the side of nephrectomy, surgical technique and anastomosing pattern, and their injuries were the most frequent factor of the conversion from laparoscopic to open surgery. With increase of laparoscopic nephrectomy in donors, accurate venous anatomy was paid more and more attention to because venous bleeding could also lead to conversion to open nephrectomy. Multidetector CT (MDCT) could supplant the conventional excretory urography and renal catheter angiography and could accurately depict the donors' vessels, vascular variations. In addition, MDCT can excellently evaluate the status of donor kidney, collecting system and other pertinent anatomy details. Accurate master of related vascular anatomy can facilitate operation plan and success of operation and can contribute to the rapid development of living donor kidney transplantation. MDCT has become the choice of preoperative one-stop image assessment for living renal donors.
Viable bacteria associated with red blood cells and plasma in freshly drawn blood donations.
Damgaard, Christian; Magnussen, Karin; Enevold, Christian; Nilsson, Martin; Tolker-Nielsen, Tim; Holmstrup, Palle; Nielsen, Claus Henrik
2015-01-01
Infection remains a leading cause of post-transfusion mortality and morbidity. Bacterial contamination is, however, detected in less than 0.1% of blood units tested. The aim of the study was to identify viable bacteria in standard blood-pack units, with particular focus on bacteria from the oral cavity, and to determine the distribution of bacteria revealed in plasma and in the red blood cell (RBC)-fraction. Cross-sectional study. Blood were separated into plasma and RBC-suspensions, which were incubated anaerobically or aerobically for 7 days on trypticase soy blood agar (TSA) or blue lactose plates. For identification colony PCR was performed using primers targeting 16S rDNA. Blood donors attending Capital Region Blood Bank, Copenhagen University Hospital, Rigshospitalet, Hvidovre, Denmark, October 29th to December 10th 2013. 60 donors (≥50 years old), self-reported medically healthy. Bacterial growth was observed on plates inoculated with plasma or RBCs from 62% of the blood donations. Growth was evident in 21 (35%) of 60 RBC-fractions and in 32 (53%) of 60 plasma-fractions versus 8 of 60 negative controls (p = 0.005 and p = 2.6x10-6, respectively). Propionibacterium acnes was found in 23% of the donations, and Staphylococcus epidermidis in 38%. The majority of bacteria identified in the present study were either facultative anaerobic (59.5%) or anaerobic (27.8%) species, which are not likely to be detected during current routine screening. Viable bacteria are present in blood from donors self-reported as medically healthy, indicating that conventional test systems employed by blood banks insufficiently detect bacteria in plasma. Further investigation is needed to determine whether routine testing for anaerobic bacteria and testing of RBC-fractions for adherent bacteria should be recommended.
Pierro, Lucia; Matturro, Bruna; Rossetti, Simona; Sagliaschi, Marco; Sucato, Salvatore; Alesi, Eduard; Bartsch, Ernst; Arjmand, Firoozeh; Papini, Marco Petrangeli
2017-07-25
A pilot-scale study aiming to evaluate the potential use of poly-3-hydroxy-butyrate (PHB) as an electron donor source for in situ bioremediation of chlorinated hydrocarbons in groundwater was conducted. Compared with commercially available electron donors, PHB offers a restricted fermentation pathway (i.e., through acetic acid and molecular hydrogen) by avoiding the formation of any residual carbon that could potentially spoil groundwater quality. The pilot study was carried out at an industrial site in Italy, heavily contaminated by different chlorinated aliphatic hydrocarbons (CAHs). Prior to field testing, PHB was experimentally verified as a suitable electron donor for biological reductive dechlorination processes at the investigated site by microcosm studies carried out on site aquifer material and measuring the quantitative transformation of detected CAHs to ethene. Owing to the complex geological characteristics of the aquifer, the use of a groundwater circulation well (GCW) was identified as a potential strategy to enable effective delivery and distribution of electron donors in less permeable layers and to mobilise contaminants. A 3-screened, 30-m-deep GCW coupled with an external treatment unit was installed at the site. The effect of PHB fermentation products on the in situ reductive dechlorination processes were evaluated by quantitative real-time polymerase chain reaction (qPCR). The results from the first 4 months of operation clearly demonstrated that the PHB fermentation products were effectively delivered to the aquifer and positively influenced the biological dechlorination activity. Indeed, an increased abundance of Dehalococcoides mccartyi (up to 6.6 fold) and reduced CAH concentrations at the installed monitoring wells were observed. Copyright © 2016 Elsevier B.V. All rights reserved.
Tiwari, Aseem K; Bhardwaj, Gunjan; Dara, Ravi C; Arora, Dinesh; Aggarwal, Geet; Bhargava, Richa; Madan, Kaushal
2018-04-13
Post-donation counselling informs donors of unusual test results. Timely notification and counselling regarding their Transfusion Transmitted Infection (TTI) status is necessary for early clinical intervention in the donor and reducing risk of transmission. We share our experience with respect to Hepatitis B (HBV) and Hepatitis C (HCV) positive donors who were counselled and followed-up for clinical outcome. It was prospective 2-year study in TTI positive blood donors. Confirmed positive HBV/ HCV donors were notified to attend the donor-clinic or to visit local hepatologist for further management. At donor clinic, donor's immediate emotional response was observed; donors were offered contact-testing, associated risk factors were noted, counselled, referred to hepatologist, treated and followed-up for clinical outcome. Of 481 donors (0.91%) confirmed positives, 351 were contacted telephonically; 280 promised to attend donor clinic and 71 were referred to their local hepatologist. 145 donors attended the donor clinic, eventually. Most common immediate emotional response noted were 'feeling of fear' (55.2%) and 'disbelief' (35.2%). Most common associated risk factor was history of medical treatment/ injections without knowledge of sterilisation. Five donors availed contact testing and four (spouses in all four cases) came out positive. Of 98 donors contacted post-counselling; 89 went to hepatologist. No medication was advised to seven donors (low viral load), 59 donors completed treatment course and 23 donors were undergoing treatment at time of follow-up. Nine donors opted for alternative treatment or "no treatment". Donor-clinic proved beneficial to substantial number of donors and their families. Copyright © 2018 Elsevier Ltd. All rights reserved.
The implementation of nucleic acid amplification technology testing for living tissue donors.
Westby, J; Lomas, R J; Kearney, J N
2010-05-01
There is a significant requirement within the United Kingdom for tissue grafts from living donors. To ensure safety, blood samples from these donors are tested for pathogens at donation, and at 180 days post donation. Nucleic acid amplification technology (NAT) permits more sensitive detection of pathogens in blood samples than serum antigen testing. NAT testing can be applied to samples from living tissue donors to eliminate the need to re-test these donors 180 days post-donation before grafts can be implanted. This has major financial and operational advantages for a tissue bank, and this manuscript describes how NAT testing was assessed and implemented by NHSBT Tissue Services. When compared to traditional serum antigen testing, NAT testing was more cost effective, more convenient for donors and resulted in a greater proportion of donated grafts being made available for transplant.
de Vos, A S; Lieshout-Krikke, R W; Slot, E; Cator, E A; Janssen, M P
2016-10-01
Individuals may donate blood in order to determine their infection status after exposure to an increased infection risk. Such test-seeking behaviour decreases transfusion safety. Instances of test seeking are difficult to substantiate as donors are unlikely to admit to such behaviour. However, manifestation in a population of repeat donors may be determined using statistical inference. Test-seeking donors would be highly motivated to donate following infection risk, influencing the timing of their donation. Donation intervals within 2005-2014 of all Dutch blood donors who acquired syphilis (N = 50), HIV (N = 13), HTLV (N = 4) or HCV (N = 2) were compared to donation intervals of uninfected blood donors (N = 7 327 836) using the Anderson-Darling test. We adjusted for length bias as well as for age, gender and donation type of the infected. Additionally, the power of the proposed method was investigated by simulation. Among the Dutch donors who acquired infection, we found only a non-significant overrepresentation of short donation intervals (P = 0·54). However, we show by simulation that both relatively short and long donation intervals among infected donors can reveal test seeking. The power of the method is >90% if among 69 infected donors >35 (51%) are test seeking, or if among 320 infected donors >90 (30%) are test seeking. We show how statistical analysis may be used to reveal the extent of test seeking in repeat blood donor populations. In the Dutch setting, indications for test-seeking behaviour were not statistically significant. This may, however, be due to the low number of infected individuals. © 2016 International Society of Blood Transfusion.
Uchenna Tweteise, Patience; Natukunda, Bernard; Bazira, Joel
2016-01-01
Background. The human T-cell lymphotropic virus types 1 and 2 (HTLV 1/2) are retroviruses associated with different pathologies. HTLV-1 causes adult T-cell leukemia/lymphoma (ATL) and HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP); HTLV-2 is not clearly associated with a known clinical disease. Both viruses may be transmitted by whole blood transfusion, from mother to child predominantly through breastfeeding, and by sexual contact. Presently, none of the regional blood banks in Uganda perform routine pretransfusion screening for HTLV. The aim of this study was to determine the prevalence of anti-human T-cell lymphotropic virus types 1/2 (HTLV-1/2) antibodies among blood donors at Mbarara Regional Blood Bank in South Western Uganda. A cross-sectional study was conducted between June 2014 and September 2014. Methodology. Consecutive blood samples of 368 blood donors were screened for anti-HTLV-1/2 antibodies using an enzyme linked immunosorbent assay (ELISA). Samples reactive on a first HTLV-1/2 ELISA were further retested in duplicate using the same ELISA. Of the three hundred and sixty-eight blood donors (229 (62.2%) males and 139 (37.8%) females), only two male donors aged 20 and 21 years were HTLV-1/2 seropositive, representing a prevalence of 0.54%. Conclusion. HTLV-1/2 prevalence is low among blood donors at Mbarara Regional Blood Bank. Studies among other categories of people at risk for HTLV 1/2 infection should be carried out.
The composition of human cortical allograft bone derived from FDA/AATB-screened donors.
Pietrzak, William S; Woodell-May, Jennifer
2005-07-01
Allograft human bone is an integral part of the surgeons' armamentarium and will continue to be for the near future. The intraoperative handling and/or mechanical properties are critical to its function. These properties are significantly influenced by the composition and the structure of the bone, which varies from donor to donor. Published studies of human bone composition use bone derived from a population that may differ from the population of qualified donors from which allograft bone is derived and may not well represent the pool of clinical allograft bone. This study investigated the cortical bone composition from 20 donors (males and females, 17 to 65 years of age) that had passed the US Food and Drug Administration and American Association of Tissue Banks screening procedures for donor qualification. As such, this represents a subset of the general population. The analysis yielded the following composition: mineral (ash) = 67.0% +/- 1.3% (w/w); matrix (predominantly type I collagen and other proteins) = 31.9% +/- 1.1% (w/w); and lipid (hexane extractables) = 1.1% +/- 1.5% (w/w). In general, these results were well within the ranges specified in the literature, with the significance being the demonstration of low variability within the study population. No age or gender compositional dependency was evident in this series, possibly as a result of the relatively homogenous population, which may have limited the ability to observe trends. Visually, the bone powders ranged from nearly white to red-brown. The more intense colors appeared to be associated with greater lipid content, perhaps indicating the presence of residual oxidized lipids.
Mafirakureva, Nyashadzaishe; Mapako, Tonderai; Khoza, Star; Emmanuel, Jean C; Marowa, Lucy; Mvere, David; Postma, Maarten J; van Hulst, Marinus
2016-12-01
The aim of this study was to assess the cost effectiveness of introducing individual-donation nucleic acid testing (ID-NAT), in addition to serologic tests, compared with the exclusive use of serologic tests for the identification of hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) I and II among blood donors in Zimbabwe. The costs, health consequences, and cost effectiveness of adding ID-NAT to serologic tests, compared with serologic testing alone, were estimated from a health care perspective using a decision-analytic model. The introduction of ID-NAT in addition to serologic tests would lower the risk of HBV, HCV, and HIV transmission to 46.9, 0.3, and 2.7 per 100,000 donations, respectively. ID-NAT would prevent an estimated 25, 6, and 9 HBV, HCV, and HIV transfusion-transmitted infections per 100,000 donations, respectively. The introduction of this intervention would result in an estimated 212 quality-adjusted life-years (QALYs) gained. The incremental cost-effectiveness ratio is estimated at US$17,774/QALY, a value far more than three times the gross national income per capita for Zimbabwe. Although the introduction of NAT could further improve the safety of the blood supply, current evidence suggests that it cannot be considered cost effective. Reducing the test costs for NAT through efficient donor recruitment, negotiating the price of reagents, and the efficient use of technology will improve cost effectiveness. © 2016 AABB.
Osaki, Satoru; Anderson, James E; Johnson, Maryl R; Edwards, Niloo M; Kohmoto, Takushi
2010-01-01
The purpose of this study is to investigate the potential availability of hearts from adult donation after cardiac death (DCD) donors within an acceptable hypoxic period. We retrospectively reviewed a donor database from the University of Wisconsin Organ Procurement Organization Donor Tracking System between 2004 and 2006. The DCD population (n=78) was screened using our inclusion criteria for DCD cardiac donor suitability, including warm ischaemic time (WIT) limit of 30 min. In the same period, 70 hearts were donated from brain-dead donors. Of 78 DCD donors, 12 (15%) met our proposed DCD cardiac donor criteria. The mean WIT of these 12 DCD donors was 21 min (range 14-29 min). When inclusion criteria are further narrowed to (1) age <30 years, (2) WIT <20 min and (3) male gender, only two out of 12 met the criteria. Based on our proposed DCD cardiac donor criteria, the potential application of DCD cardiac donors would represent an increase in cardiac donation of 17% (12/70) during the 3-year period. When the criteria were narrowed to the initial 'ideal' case, only two donors met such criteria, suggesting that such 'ideal' DCD donors are rare but they do exist. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Kupek, Emil; Savi, Estela Olivo
2017-01-01
Human milk banking has been promoted to provide donated breast milk for at-risk children whose mothers cannot breastfeed them but this effort was hindered by the advent of HIV epidemic. To estimate the seroprevalence of HIV, syphilis and hepatitis B in the blood of human milk donors registered in a major maternity hospital in the northern region of the Santa Catarina State, Brazil. A retrospective study included serological tests for HIV, syphilis and hepatitis B screening of milk donor candidates in the 2005-2015 period. The 95% confidence intervals were calculated using the Poisson distribution. For HIV, the prevalence per 100.000 pregnant women was 155, 170 and zero over the three periods analyzed (2005-2009, 2010-2012 and 2013-2015), respectively. Syphilis prevalence per 100,000 pregnant women was 509, 460 and 1749 in the three periods analyzed. For the HBsAg marker of recent hepatitis B infection, the prevalence on the same scale was 254, 231 and 299, respectively, while the anti-HBc prevalence, a marker of lifetime risk for hepatitis B infection, was 7339 in the 2010-2012 period and 3874 in the 2013-2015 period. High prevalence of HIV, syphilis and hepatitis B was found for the 2005-2015 period among breastfeeding mothers who offered to donate their exceeding milk to a human milk bank in Brazil. Despite apparent elimination of the HIV by the end of the period, the decline was not statistically significant. There was no significant change in the acute hepatitis B prevalence over time but the increased syphilis prevalence in the most recent period was statistically significant. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Computational Design of Metal Ion Sequestering Agents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, Benjamin P.; Rapko, Brian M.
Organic ligands that exhibit a high degree of metal ion recognition are essential precursors for developing separation processes and sensors for metal ions. Since the beginning of the nuclear era, much research has focused on discovering ligands that target specific radionuclides. Members of the Group 1A and 2A cations (e.g., Cs, Sr, Ra) and the f-block metals (actinides and lanthanides) are of primary concern to DOE. Although there has been some success in identifying ligand architectures that exhibit a degree of metal ion recognition, the ability to control binding affinity and selectivity remains a significant challenge. The traditional approach formore » discovering such ligands has involved lengthy programs of organic synthesis and testing that, in the absence of reliable methods for screening compounds before synthesis, have resulted in much wasted research effort. This project seeks to enhance and strengthen the traditional approach through computer-aided design of new and improved host molecules. Accurate electronic structure calculations are coupled with experimental data to provide fundamental information about ligand structure and the nature of metal-donor group interactions (design criteria). This fundamental information then is used in a molecular mechanics model (MM) that helps us rapidly screen proposed ligand architectures and select the best members from a set of potential candidates. By using combinatorial methods, molecule building software has been developed that generates large numbers of candidate architectures for a given set of donor groups. The specific goals of this project are: • further understand the structural and energetic aspects of individual donor group- metal ion interactions and incorporate this information within the MM framework • further develop and evaluate approaches for correlating ligand structure with reactivity toward metal ions, in other words, screening capability • use molecule structure building software to generate large numbers of candidate ligand architectures for given sets of donor groups • screen candidates and identify ligand architectures that will exhibit enhanced metal ion recognition. These new capabilities are being applied to ligand systems identified under other DOEsponsored projects where studies have suggested that modifying existing architectures will lead to dramatic enhancements in metal ion binding affinity and selectivity. With this in mind, we are collaborating with Professors R. T. Paine (University of New Mexico), K. N. Raymond (University of California, Berkeley), and J. E. Hutchison (University of Oregon), and Dr. B. A. Moyer (Oak Ridge National Laboratory) to obtain experimental validation of the predicted new ligand structures. Successful completion of this study will yield molecular-level insight into the role that ligand architecture plays in controlling metal ion complexation and will provide a computational approach to ligand design.« less
Liao, Qiao; Shan, Zhengang; Wang, Min; Huang, Jieting; Xu, Ru; Huang, Ke; Tang, Xi; Zhang, Weiyun; Nelson, Kenrad; Li, Chengyao; Fu, Yongshui; Rong, Xia
2017-11-01
In 2014, an outbreak of dengue virus (DENV) infection led to 45 171 clinical cases diagnosed in Guangdong province, Southern China. However, the potential risk of blood donors asymptomatically infected with DENV has not been evaluated . In the current study we detected anti-DENV IgG antibody and RNA in volunteer Chinese blood donors. We found that anti-DENV IgG antibody was positively detected in 3.4% (51/1500) and two donors were detected as being DENV RNA positive out of 3000 blood samples. We concluded that the presence of potential DENV in blood donors might be potential risk for blood safety. Therefore, screening for DENV infection should be considered in blood donations during a period of dengue outbreak in high epidemic area of China. © 2017 Wiley Periodicals, Inc.
Gap Test Calibrations And Their Scalin
NASA Astrophysics Data System (ADS)
Sandusky, Harold
2012-03-01
Common tests for measuring the threshold for shock initiation are the NOL large scale gap test (LSGT) with a 50.8-mm diameter donor/gap and the expanded large scale gap test (ELSGT) with a 95.3-mm diameter donor/gap. Despite the same specifications for the explosive donor and polymethyl methacrylate (PMMA) gap in both tests, calibration of shock pressure in the gap versus distance from the donor scales by a factor of 1.75, not the 1.875 difference in their sizes. Recently reported model calculations suggest that the scaling discrepancy results from the viscoelastic properties of PMMA in combination with different methods for obtaining shock pressure. This is supported by the consistent scaling of these donors when calibrated in water-filled aquariums. Calibrations and their scaling are compared for other donors with PMMA gaps and for various donors in water.
Potential of soluble CD26 as a serum marker for colorectal cancer detection
Cordero, Oscar J; Imbernon, Monica; Chiara, Loretta De; Martinez-Zorzano, Vicenta S; Ayude, Daniel; de la Cadena, Maria Paez; Rodriguez-Berrocal, F Javier
2011-01-01
Colorectal cancer is characterized by a low survival rate even though the basis for colon cancer development, which involves the evolution of adenomas to carcinoma, is known. Moreover, the mortality rates continue to rise in economically transitioning countries although there is the opportunity to intervene in the natural history of the adenoma–cancer sequence through risk factors, screening, and treatment. Screening in particular accounted for most of the decline in colorectal cancer mortality achieved in the USA during the period 1975-2000. Patients show a better prognosis when the neoplasm is diagnosed early. Among the variety of screening strategies, the methods range from invasive and costly procedures such as colonoscopy to more low-cost and non-invasive tests such as the fecal occult blood test (guaiac and immunochemical). As a non-invasive biological serum marker would be of great benefit because of the performance of the test, several biomarkers, including cytologic assays, DNA and mRNA, and soluble proteins, have been studied. We found that the soluble CD26 (sCD26) concentration is diminished in serum of colorectal cancer patients compared to healthy donors, suggesting the potential utility of a sCD26 immunochemical detection test for early diagnosis. sCD26 originates from plasma membrane CD26 lacking its transmembrane and cytoplasmic domains. Some 90%–95% of sCD26 has been associated with serum dipeptidyl peptidase IV (DPP-IV) activity. DPP-IV, assigned to the CD26 cluster, is a pleiotropic enzyme expressed mainly on epithelial cells and lymphocytes. Our studies intended to validate this test for population screening to detect colorectal cancer and advanced adenomas are reviewed here. PMID:21773075
Negotiating boundaries: Accessing donor gametes in India.
Widge, A; Cleland, J
2011-01-01
This paper documents how couples and providers access donor materials for conception in the Indian context and perceptions about using them. The objective is to facilitate understanding of critical issues and relevant concerns. A postal survey was conducted with a sample of 6000 gynaecologists and in-depth interviews were -conducted with 39 gynaecologists in four cities. Donor gametes are relatively more acceptable than a few years ago, especially if confidentiality can be -maintained, though lack of availability of donor materials is sometimes an impediment to infertility treatment. Donor sperms are usually accessed from in-house or commercial sperm banks, pathology laboratories, IVF centres, -professional donors, relatives or friends. There is scepticism about screening procedures of sperm banks. Donor eggs are usually accessed from voluntary donors, friends, relatives, egg sharing programmes, donation from other patients, advertising and commercial donors. There are several concerns regarding informed consent for using donated gametes, using -relatives and friends gametes, the unregulated use of gametes and embryos, record keeping and documentation, -unethical and corrupt practices and commercialisation. These issues need to be addressed by patients, providers and regulatory authorities by providing -information, counselling, ensuring informed consent, addressing exploitation and commercialisation, ensuring -monitoring, proper documentation and transparency.
Negotiating boundaries: Accessing donor gametes in India
Widge, A.; Cleland, J.
2011-01-01
Background: This paper documents how couples and providers access donor materials for conception in the Indian context and perceptions about using them. The objective is to facilitate understanding of critical issues and relevant concerns. Methods: A postal survey was conducted with a sample of 6000 gynaecologists and in-depth interviews were conducted with 39 gynaecologists in four cities. Results: Donor gametes are relatively more acceptable than a few years ago, especially if confidentiality can be maintained, though lack of availability of donor materials is sometimes an impediment to infertility treatment. Donor sperms are usually accessed from in-house or commercial sperm banks, pathology laboratories, IVF centres, professional donors, relatives or friends. There is scepticism about screening procedures of sperm banks. Donor eggs are usually accessed from voluntary donors, friends, relatives, egg sharing programmes, donation from other patients, advertising and commercial donors. There are several concerns regarding informed consent for using donated gametes, using relatives and friends gametes, the unregulated use of gametes and embryos, record keeping and documentation, unethical and corrupt practices and commercialisation. Conclusion: These issues need to be addressed by patients, providers and regulatory authorities by providing information, counselling, ensuring informed consent, addressing exploitation and commercialisation, ensuring monitoring, proper documentation and transparency. PMID:24753849
Hota, Susy S; Surangiwala, Salman; Paterson, Aimee S; Coburn, Bryan; Poutanen, Susan M
2018-04-18
There is growing evidence that fecal microbiota transplantation (FMT) is an effective treatment for recurrent Clostridium difficile infection, but little guidance exists for implementation of FMT programs. The objective of this study is to describe the program characteristics and protocols of 9 planned or operating FMT programs in the Southern Ontario Fecal Microbiota Transplantation (SOFT) Movement, to help guide future FMT program implementation. A 59-item survey was administered electronically to clinical leads of the SOFT Movement on June 2, 2016. The survey evaluated 7 domains: FMT program characteristics, FMT recipients, donor screening/selection, transplant manufacturing, FMT administration, good manufacturing procedures/biosafety procedures and infection-control procedures. We used descriptive statistics to analyze quantitative data. All 9 programs responded to the survey: 6 were active, 1 had FMT standard operating procedures developed but did not have clinical experience, and 2 were in the process of forming FMT programs. All 6 active programs performed FMT in adult patients with C. difficile infection. About 1300 FMT procedures were performed between 2003 and 2016. Five of the 6 operating programs administered the preparation via enema. Programs were driven primarily by physicians. All programs used universal FMT donors and followed Health Canada's screening guidelines, with considerable variability in screening frequency (every 3-6 mo) and modality. Locations for transplant preparation and manufacturing protocols varied across programs. Stool mass for FMT ranged from 20 g to 150 g, and transplant volume ranged from 25 mL to 300 mL. The experience of this high-volume regional FMT network highlights current challenges in FMT program development, including a high reliance on physicians and the costly nature of donor screening. Standardization and optimization through development of regional centres of excellence for FMT donor recruitment and administration should be explored. Copyright 2018, Joule Inc. or its licensors.
Shukla, U; Deval, B; Jansa Perez, M; Hamoda, H; Savvas, M; Narvekar, N
2013-03-01
Has the change in donor anonymity legislation in UK affected the recruitment of men wanting to be sperm donors and also affected the attitudes of the practitioners who provide donor sperm treatment? We have performed fewer IUI and IVF treatments using donor sperm following the change in legislation in April 2005 than before. However, we have seen an overall increase in men wanting to donate their sperm, including a small increase in men from ethnic minorities. Sweden, which removed donor anonymity in 1985, had an initial drop in men wanting to donate and then 10 years later started to have an increase. The Human Fertilisation and Embryology Authority (HFEA) and other studies in the UK have shown an overall downward trend, but have not been able to compare large time scales either side of the change in legislation. This was a retrospective descriptive study that looked at all men who approached the clinic between the years 2000 and 2010, i.e. 5 years either side of the change in legislation (April 2005). Overall, we had 24 men wanting to be donors prior to the rule change and 65 men after the rule change. We also investigated the total number of all treatments with donor sperm, and this included a total of 1004 donor sperm treatments prior to the change in legislation and 403 donor sperm treatments after the change in legislation. The study was set in an NHS IVF clinic in South East London. We compared the indicators of service provision, provider practices and donor attitudes, in the period between April 2000 and March 2005 (Group A) with those between April 2005 and March 2010 (Group B), i.e. 5 years either side of the change in legislation. There were 875 IUI treatments and 129 IVF or ICSI treatments in Group A and 325 IUI and 78 IVF/ICSI treatments in Group B with the use of donor sperm, of which, 11.9% (119 out of 1004) in Group A and 39.5% (159 out of 403) in Group B were with donor sperm recruited by our unit. The clinical pregnancy rate per cycle of treatment in Group A was (86 out of 875) 9.8% for IUI and (27 out of 129) 20.9% for IVF/ICSI and in Group B (32/325) 9.8% and (28 out of 78) 35.9%, respectively. There was a sharp yearly fall in donor sperm treatments from 2004. Twenty-four men were screened in Group A, of which 18 (75.0%) were recruited for long-term storage and 12 (50%) were registered as donors with the HFEA when the sperm was used, whereas in Group B, 65 men were screened, 53 (82.0%) were recruited and 24 (36.92%) were registered as donors. Six (24.0%) men in Group A failed in screening because of poor semen analysis when compared with 9 (13.8%) men in Group B. The majority of post-recruitment dropouts were because of loss of follow-up or withdrawal of consent. More donors in Group A were white (92.0 versus 77.0%) and born in UK (92.0 versus 68.0%) when compared with those in Group B. Donors in Group B were more likely to be single (46.0 versus 4.0%) and to have informed their relevant partner of donation (71.0 versus 54.0%) when compared with those in Group A. 83.0% of donors in Group A were heterosexual when compared with 69.0% in Group B. The primary reason for donating in both groups of potential donors was 'wanting to help' (46.0% 'altruistic donors' in Group A versus 72.0% in Group B). Fewer donors in Group B (37%) had specific restrictions about the use of their sperm when compared with 46.0% in Group A. As this was a retrospective study, there is a chance for the introduction of bias. We have shown that despite no active in-house recruitment procedures, we are managing to recruit more potential sperm donors after the change in UK legislation, and we are able to meet the demand for treatments with in-house recruited donor sperm that is a reassuring finding for donor sperm treatment services in the wider UK. No external funds were sought for this work. None of the authors have any competing interests to declare.
Dim, Cyril C; Onyedum, Cajetan C; Dim, Ngozi R; Chukwuka, Judith C
2015-01-01
The sustainability of donor-supported cervical cancer screening for HIV-positive women in underresourced setting is a concern. The authors aimed to determine the willingness of HIV-positive women for out-of-pocket payment for the cancer screening, if necessary. Questionnaires were administered to 400 HIV-positive women at the Adult HIV clinic, University of Nigeria Teaching Hospital (UNTH), Enugu, Nigeria. In all 11 (2.8%) respondents were aware of Pap smear, but only 1 (9.1%) of them had used it. After cervical cancer screening counseling, 378 (94.5%) respondents were willing to pay for Pap smear, irrespective of the cost. This willingness showed no trend across marital or educational groups. Younger age of respondents was not associated with willingness to pay for Pap smear (odds ratio = 1.24; confidence interval 95%: 0.52, 2.94). Willingness to pay for Pap smear by HIV-positive women in Enugu, Nigeria, is high. This has implication for the program sustainability. © The Author(s) 2013.
HIV and hepatitis C virus RNA in seronegative organ and tissue donors.
Challine, Dominique; Pellegrin, Bertrand; Bouvier-Alias, Magali; Rigot, Pierrette; Laperche, Liliane; Pawlotsky, Jean-Michel
The objective of our study was to determine whether nucleic acid testing could detect HIV RNA or hepatitis C virus (HCV) RNA in a large series of seronegative organ and tissue donors, and whether this technique should be routinely used to improve viral safety of grafts. We studied 2236 organ donors, 636 tissue donors, and 177 cornea donors. We identified five HCV RNA-positive donors in 2119 HCV-seronegative organ donors, and one HCV RNA-positive donor in 631 HCV-seronegative tissue donors. No HIV-seronegative, HIV RNA-positive donor was identified. Our data suggest that routine nucleic acid testing of organ and tissue donors might increase viral safety in transplantation.
Van der Bij, Akke K; Coutinho, Roel A; Van der Poel, Cees L
2006-10-01
To evaluate the effectiveness of blood donor selection, this study reports risk profiles of donors with transfusion-transmissible infections as obtained by ongoing surveillance, 1995 through 2003, in the Netherlands. A surveillance program was installed to monitor risk profiles among new and repeat donors infected with human immunodeficiency virus (HIV), hepatitis C virus (HCV), hepatitis B virus (HBV), or human T-lymphotropic virus (HTLV), or positive for the presence of syphilis antibodies. At posttest counseling, a physician interviewed donors to clarify possible sources of infection. A total of 167 repeat donors and 404 new donors were interviewed: 33 with HIV, 123 with HCV, 279 with HBV, 21 with HTLV, and 112 with syphilis antibodies. Most HBV, HCV, and HTLV infections were among new donors (80, 85, and 67%), whereas most HIV infections were among repeat donors (79%). Nearly 25 percent of the donors did not report factors at screening that would have deferred them from donating blood. At posttest interviews, new donors with HCV often reported injecting drug use (19%). Repeat donors with HIV often reported male-to-male sex (8/26, 31%). A significant level of deferrable behavioral risks was found among donors with confirmed transfusion-transmissible infections that persist despite current donor selection. Reporting such behavior at initial donor selection would have eliminated a substantial part of the infections found. This study argues against relaxing the existing donor deferral of persons practicing male-to-male sex, given their significant proportion of HIV infections among repeat donors. Systematic surveillance of risk factors among infected blood donors provides ongoing information about the effectivity of donor selection and is recommended to evaluate and optimize blood policies.
Donor-transmitted, donor-derived, and de novo cancer after liver transplant.
Chapman, Jeremy R; Lynch, Stephen V
2014-03-01
Cancer is the third most common cause of death (after cardiovascular disease and infection) for patients who have a functioning kidney allograft. Kidney and liver transplant recipients have similar cancer risks because of immunosuppression but different risks because of differences in primary diseases that cause renal and hepatic failure and the inherent behavior of cancers in the liver. There are 4 types of cancer that may develop in liver allograft recipients: (1) recurrent cancer, (2) donor-transmitted cancer, (3) donor-derived cancer, and (4) de novo cancer. Identification of potential donor cancer transmission may occur at postmortem examination of a deceased donor or when a probable donor-transmitted cancer is identified in another recipient. Donor-transmitted cancer after liver transplant is rare in Australia, the United Kingdom, and the United States. Aging of the donor pool may increase the risk of subclinical cancer in donors. Liver transplant recipients have a greater risk of de novo cancer than the general population, and risk factors for de novo cancer in liver transplant recipients include primary sclerosing cholangitis, alcoholic liver disease, smoking, and increased age. Liver transplant recipients may benefit from cancer screening because they have a high risk, are clearly identifiable, and are under continuous medical supervision.
2017-01-01
The use of donor human milk is increasing for high-risk infants, primarily for infants born weighing <1500 g or those who have severe intestinal disorders. Pasteurized donor milk may be considered in situations in which the supply of maternal milk is insufficient. The use of pasteurized donor milk is safe when appropriate measures are used to screen donors and collect, store, and pasteurize the milk and then distribute it through established human milk banks. The use of nonpasteurized donor milk and other forms of direct, Internet-based, or informal human milk sharing does not involve this level of safety and is not recommended. It is important that health care providers counsel families considering milk sharing about the risks of bacterial or viral contamination of nonpasteurized human milk and about the possibilities of exposure to medications, drugs, or herbs in human milk. Currently, the use of pasteurized donor milk is limited by its availability and affordability. The development of public policy to improve and expand access to pasteurized donor milk, including policies that support improved governmental and private financial support for donor milk banks and the use of donor milk, is important. Copyright © 2017 by the American Academy of Pediatrics.
Donor-derived infections in solid organ transplant patients: toward a holistic approach.
Benamu, Esther; Wolfe, Cameron R; Montoya, José G
2017-08-01
Solid organ demand far exceeds organ supply. Strategies to increase the donor pool include the liberalization of selection criteria without increasing the risk of unexpected donor-derived infection (DDI), a rare complication of transplantation carrying high morbidity and mortality. We review the challenging aspects in the prevention of DDI, focusing on the complexities of data sharing and efficient communication and the role infectious diseases specialists play in the process. Advances in donor screening, transmission recognition and reporting allow for a better estimation of the risk of DDI. However, there is great variability in the frequency and methods with which organ procurement organizations report transmission events.Moreover, the Scientific Registry of Transplant Recipients provides limited donor and recipient outcome infectious diseases related data. Infectious disease contribution to the allocation process has been found to improve organ donation efficiency and communication between involved parties. Although communication gaps are strongly associated with infection transmission (relative risk 2.36%, confidence interval 1.48-3.78), effective communication minimizes or prevents infection in transplant recipients (X(1) 13.13, P = 0.0003). Prospective research is still required to define optimal screening protocols and further prevent transmission of infection. A holistic approach is likely to result in enhanced transplantation safety. Toward this goal, development of standards of investigation; improvement in reporting and data sharing; and strategies ensuring coordinated and rapid communication among parties involved in the allocation process need to be pursued.
Unpasteurized Shared Human Milk Use in Pediatric Inpatients: Health and Ethical Implications.
Barbas, Kimberly H; Sussman-Karten, Karen; Kamin, Daniel; Huh, Susanna Y
2017-06-01
Growing evidence supporting the health benefits of human milk, particularly in the preterm population, has led to rising demand for donor human milk in NICUs and pediatric hospitals. There are no previous reports describing the use of unpasteurized shared human milk (USHM) in the hospital setting, but the use of USHM solicited from community donors through social networks appears to be common. Many pediatric hospitals permit inpatients to receive breast milk that has been screened and pasteurized by a human milk banking organization and will provide pasteurized donor human milk (PDHM) only to infants who are preterm or have specific medical conditions. These policies are designed to minimize potential adverse effects from improperly handled or screened donor milk and to target patients who would experience the greatest benefit in health outcomes with donor milk use. We explore the ethical and health implications of 2 cases of medically complex infants who did not meet criteria in our tertiary care hospital for the use of PDHM from a regulated human milk bank and were incidentally found to be using USHM. These cases raise questions about how best to balance the ethical principles of beneficence, nonmaleficence, justice, and patient autonomy in the provision of PDHM, a limited resource. Health care staff should ask about USHM use to provide adequate counseling about the risks and benefits of various feeding options in the context of an infant's medical condition. Copyright © 2017 by the American Academy of Pediatrics.
Comparison of candidate vCJD in vitro diagnostic assays using identical sample sets.
Cooper, J K; Ladhani, K; Minor, P
2012-02-01
With four transfusion related transmissions of variant Creutzfeldt-Jakob Disease (vCJD), three of which developed clinical disease and the other died of other causes but was positive for markers of infection, there is an increased urgency to identify and implement a test for blood donor screening. With limited amounts of blood samples from vCJD cases available test evaluation is challenging. Alternative approaches are therefore needed. Control and vCJD tissues homogenates, where levels of markers of infectivity are known, were sequentially diluted in pooled human plasma. Identical sets of samples were provided blind to research groups developing diagnostic tests for vCJD; identical sample sets allows for direct comparisons of sensitivity to be made. Control and vCJD tissue homogenates were sequentially diluted in pooled human plasma (detergent solvent treated or cryo-depleted) supplied by commercial fractionators. Dilutions of vCJD tissues were within and beyond the limits of detection previously determined by the conformation-dependent immunoassay (Cooper et al.: Vox Sang 2007;92:302-310; Bellon et al.: J Gen Virol 2003;84: 1921-1925). A number of methods were used for the analysis of the blinded panels; with background signal from the normal prion protein (PrP) being removed by digestion with proteinase, epitope protection or selective capture of PrP(tse). Assay sensitivities were directly compared using identical sample sets. This approach identified several transmissible spongiform encephalopathies (TSE) diagnostic tests, based on different principles, high in analytical sensitivity that reproducibly detected markers of vCJD infectivity in tissue homogenates. The approach outlined has successfully compared in vitro diagnostics assays for their sensitivity and reproducibility and is a first step toward the evaluation of an assay suitable for blood donor screening/diagnosis of vCJD. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.
Green, Anthony P; Turner, Nicholas J; O'Reilly, Elaine
2014-01-01
The widespread application of ω-transaminases as biocatalysts for chiral amine synthesis has been hampered by fundamental challenges, including unfavorable equilibrium positions and product inhibition. Herein, an efficient process that allows reactions to proceed in high conversion in the absence of by-product removal using only one equivalent of a diamine donor (ortho-xylylenediamine) is reported. This operationally simple method is compatible with the most widely used (R)- and (S)-selective ω-TAs and is particularly suitable for the conversion of substrates with unfavorable equilibrium positions (e.g., 1-indanone). Significantly, spontaneous polymerization of the isoindole by-product generates colored derivatives, providing a high-throughput screening platform to identify desired ω-TA activity. PMID:25138082
[Groupamatic 360 C1 and automated blood donor processing in a transfusion center].
Guimbretiere, J; Toscer, M; Harousseau, H
1978-03-01
Automation of donor management flow path is controlled by: --a 3 slip "port a punch" card, --the groupamatic unit with a result sorted out on punch paper tape, --the management computer off line connected to groupamatic. Data tracking at blood collection time is made by punching a card with the donor card used as a master card. Groupamatic performs: --a standard blood grouping with one run for registered donors and two runs for new donors, --a phenotyping with two runs, --a screening of irregular antibodies. Themanagement computer checks the correlation between the data of the two runs or the data of a single run and that of previous file. It updates the data resident in the central file and prints out: --the controls of the different blood group for the red cell panel, --The listing of error messages, --The listing of emergency call up, --The listing of collected blood units when arrived at the blood center, with quantitative and qualitative information such as: number of blood, units collected, donor addresses, etc., --Statistics, --Donor cards, --Diplomas.
Imaging screening of catastrophic neurological events using a software tool: preliminary results.
Fernandes, A P; Gomes, A; Veiga, J; Ermida, D; Vardasca, T
2015-05-01
In Portugal, as in most countries, the most frequent organ donors are brain-dead donors. To answer the increasing need for transplants, donation programs have been implemented. The goal is to recognize virtually all the possible and potential brain-dead donors admitted to hospitals. The aim of this work was to describe preliminary results of a software application designed to identify devastating neurological injury victims who may progress to brain death and can be possible organ donors. This was an observational, longitudinal study with retrospective data collection. The software application is an automatic algorithm based on natural language processing for selected keywords/expressions present in the cranio-encephalic computerized tomography (CE CT) scan reports to identify catastrophic neurological situations, with e-mail notification to the Transplant Coordinator (TC). The first 7 months of this application were analyzed and compared with the standard clinical evaluation methodology. The imaging identification tool showed a sensitivity of 77% and a specificity of 66%; predictive positive value (PPV) was 0.8 and predictive negative value (PNV) was 0.7 for the identification of catastrophic neurological events. The methodology proposed in this work seems promising in improving the screening efficiency of critical neurological events. Copyright © 2015 Elsevier Inc. All rights reserved.
Cancer Incidence and Mortality in a Cohort of US Blood Donors: A 20-Year Study
Hirschler, Nora V.; Chinn, Artina; Busch, Michael P.; Custer, Brian
2013-01-01
Blood donors are considered one of the healthiest populations. This study describes the epidemiology of cancer in a cohort of blood donors up to 20 years after blood donation. Records from donors who participated in the Retroviral Epidemiology Donor Study (REDS, 1991–2002) at Blood Centers of the Pacific (BCP), San Francisco, were linked to the California Cancer Registry (CCR, 1991–2010). Standardized incidence ratios (SIR) were estimated using standard US 2000 population, and survival analysis used to compare all-cause mortality among donors and a random sample of nondonors with cancer from CCR. Of 55,158 eligible allogeneic blood donors followed-up for 863,902 person-years, 4,236 (7.7%) primary malignant cancers were diagnosed. SIR in donors was 1.59 (95% CI = 1.54,1.64). Donors had significantly lower mortality (adjusted HR = 0.70, 95% CI = 0.66–0.74) compared with nondonor cancer patients, except for respiratory system cancers (adjusted HR = 0.93, 95% CI = 0.82–1.05). Elevated cancer incidence among blood donors may reflect higher diagnosis rates due to health seeking behavior and cancer screening in donors. A “healthy donor effect” on mortality following cancer diagnosis was demonstrated. This population-based database and sample repository of blood donors with long-term monitoring of cancer incidence provides the opportunity for future analyses of genetic and other biomarkers of cancer. PMID:24489545
21 CFR 1271.80 - What are the general requirements for donor testing?
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.80 What are... donor specimen for testing at the time of recovery of cells or tissue from the donor; or up to 7 days before or after recovery, except: (1) For donors of peripheral blood stem/progenitor cells, bone marrow...
21 CFR 1271.80 - What are the general requirements for donor testing?
Code of Federal Regulations, 2012 CFR
2012-04-01
... donor specimen for testing at the time of recovery of cells or tissue from the donor; or up to 7 days before or after recovery, except: (1) For donors of peripheral blood stem/progenitor cells, bone marrow... ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.80 What are...
21 CFR 1271.80 - What are the general requirements for donor testing?
Code of Federal Regulations, 2013 CFR
2013-04-01
... donor specimen for testing at the time of recovery of cells or tissue from the donor; or up to 7 days before or after recovery, except: (1) For donors of peripheral blood stem/progenitor cells, bone marrow... ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.80 What are...
21 CFR 1271.80 - What are the general requirements for donor testing?
Code of Federal Regulations, 2014 CFR
2014-04-01
... donor specimen for testing at the time of recovery of cells or tissue from the donor; or up to 7 days before or after recovery, except: (1) For donors of peripheral blood stem/progenitor cells, bone marrow... ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.80 What are...
21 CFR 1271.80 - What are the general requirements for donor testing?
Code of Federal Regulations, 2011 CFR
2011-04-01
... donor specimen for testing at the time of recovery of cells or tissue from the donor; or up to 7 days before or after recovery, except: (1) For donors of peripheral blood stem/progenitor cells, bone marrow... ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.80 What are...
Qiu, Xiaoxing; Swanson, Priscilla; Tang, Ning; Leckie, Gregor W; Devare, Sushil G; Schochetman, Gerald; Hackett, John
2012-02-01
Xenotropic murine leukemia virus-related virus (XMRV) has been reported in patients with prostate cancer and chronic fatigue syndrome. Although results have been conflicting, the potential of XMRV as an infectious human retrovirus has raised concerns about transfusion safety. To address this issue, normal and retrovirus-infected blood donors were screened for evidence of XMRV infection. Plasma from 1000 US, 100 human immunodeficiency virus Type 1-infected Cameroonian, and 642 human T-lymphotropic virus Type I (HTLV-I)-infected or uninfected Japanese blood donors as well as 311 sexually transmitted disease diagnostic specimens were screened for antibodies to XMRV gp70 and p15E using chemiluminescent immunoassays (CMIAs). CMIA-reactive samples were evaluated by p30 CMIA, Western blot, and real-time reverse transcriptase polymerase chain reaction. XMRV seroreactivity was low (0%-0.6%) with the exception of the HTLV-I-infected donors (4.9%). Antibody was detected against only a single XMRV protein (p15E or gp70); none of the seroreactive samples had detectable XMRV pol or env sequences. The elevated seroreactivity in HTLV-I-infected donors was due to an increased p15E seroreactive rate (4.1%). Inspection of XMRV and HTLV sequences revealed a high level of conservation within the immunodominant region (IDR) of the transmembrane protein. In some cases, HTLV IDR peptide competitively reduced the XMRV p15E signal. Based on the low prevalence of seroreactivity, detection of antibody to only a single XMRV protein and the absence of XMRV sequences, this study finds no compelling evidence of XMRV in normal or retrovirus-infected blood donors. The increased p15E seroreactivity observed in HTLV infection is likely due to cross-reactive antibodies. © 2012 American Association of Blood Banks.
Aggarwal, V; Prakash, C; Yadav, S; Chattopadhya, D
1997-12-01
Any change in risk behavior related to acquisition of human immunodeficiency virus (HIV) infection is likely to reduce simultaneously the risk for other agents transmitted through identical routes. A study carried out in the city of Delhi, India on the load of transfusion associated infections among multitransfused (MT) children in relation to mandatory screening of HIV infection in donated blood indicated unchanged prevalence of hepatitis B virus (HBV), hepatitis C virus (HCV) and hepatitis D virus (HDV) infections among the group of MT children transfused after the implementation of mandatory screening of HIV infections in blood banks, i.e. post-implementation period (prevalence of HBV, HCV and HDV being 32.8%, 31.3% and 1.6% respectively) compared to a group of MT children transfused over a similar duration before the implementation of mandatory screening i.e. pre-implementation period (prevalence of HBV, HCV and HDV being 28.1%, 26.6% and 1.6% respectively). However, reduction could be recorded in the prevalence of IgM and IgG classes of antibodies to both CMV and HSV-2 infections among MT children receiving transfusion during the post-implementation period (prevalence of 3.1% and 37.1% for CMV IgM and CMV IgG respectively; prevalence of 3.1% and 25% for HSV-2 IgM and HSV-2 IgG, respectively) compared to the group of MT children transfused in the pre-implementation period (prevalence of 15.6% and 56.3% for CMV IgM and CMV IgG respectively; prevalence of 18.8% and 45.2% for HSV-2 IgM and HSV-2 IgG, respectively). These reductions were statistically significant (p values < 0.02 and < 0.05 for CMV IgM and CMV IgG; p values < 0.01 and < 0.02 for HSV-2 IgM and HSV-2 IgG respectively). These observations were in accordance with the recorded reduction in the prevalence of CMV and HSV-2 infections and unaltered prevalence of HBV, HCV and HDV infections in the group of donors donating blood during the post-implementation period compared to those donating in the pre-implementation period. Study of epidemiological risk factors among blood donors showed a change in behavior towards safer sex practice with only 13.0% of donors in the post-implementation period having history of sex with one or more female commercial sex workers during their donation periods compared to 41.5% of donors in the pre-implementation period having similar history (p < 0.001). However no change could be recorded in the proportion of donors donating at frequency higher than the permissible guidelines among the two groups. The present study points out nosocomial transmission as well as limitations in the existing guidelines for screening of infectious agents in blood banks as possible incriminating factors towards acquisition of hepatitis virus infections in blood donors as well as in MT children.
Lefrère, Jean-Jacques; Hewitt, Patricia
2009-04-01
Transfusion transmission of the prion, the agent of variant Creutzfeldt-Jakob disease (vCJD), is now established. Subjects infected through food may transmit the disease through blood donations. The two nations most affected to date by this threat are the United Kingdom (UK) and France. The first transfusion cases have been observed in the UK over the past 5 years. In France, a few individuals who developed vCJD had a history of blood donation, leading to a risk of transmission to recipients, some of whom could be incubating the disease. In the absence of a large-scale screening test, it is impossible to establish the prevalence of infection in the blood donor population and transfused patients. This lack of a test also prevents specific screening of blood donations. Thus, prevention of transfusion transmission essentially relies at present on deferral of "at-risk" individuals. Because prions are present in both white blood cells and plasma, leukoreduction is probably insufficient to totally eliminate the transfusion risk. In the absence of a screening test for blood donations, recently developed prion-specific filters could be a solution. Furthermore, while the dietary spread of vCJD seems efficiently controlled, uncertainty remains as to the extent of the spread of prions through blood transfusion and other secondary routes.
Analyzing actual risk in malaria-deferred donors through selective serologic testing.
Nguyen, Megan L; Goff, Tami; Gibble, Joan; Steele, Whitney R; Leiby, David A
2013-08-01
Approximately 150,000 US blood donors are deferred annually for travel to malaria-endemic areas. However, the majority do not travel to the high-risk areas of Africa associated with transfusion-transmitted malaria (TTM) but visit low-risk areas such as Mexico. This study tests for Plasmodium infection among malaria-deferred donors, particularly those visiting Mexico. Blood donors deferred for malaria risk (travel, residence, or previous infection) provided blood samples and completed a questionnaire. Plasma was tested for Plasmodium antibodies by enzyme immunoassay (EIA); repeat-reactive (RR) samples were considered positive and tested by real-time polymerase chain reaction (PCR). Accepted donors provided background testing data. During 2005 to 2011, a total of 5610 malaria-deferred donors were tested by EIA, including 5412 travel deferrals. Overall, 88 (1.6%) were EIA RR; none were PCR positive. Forty-nine (55.7%) RR donors previously had malaria irrespective of deferral category, including 34 deferred for travel. Among 1121 travelers to Mexico, 90% visited Quintana Roo (no or very low risk), but just 2.2% visited Oaxaca/Chiapas (moderate or high risk). Only two Mexican travelers tested RR; both previously had malaria not acquired in Mexico. Travel to Mexico represents a large percentage of US donors deferred for malaria risk; however, these donors primarily visit no- or very-low-risk areas. No malaria cases acquired in Mexico were identified thereby supporting previous risk estimates. Consideration should be given to allowing blood donations from U.S. donors who travel to Quintana Roo and other low-risk areas in Mexico. A more effective approach to preventing TTM would be to defer all donors with a history of malaria, even if remote. © 2012 American Association of Blood Banks.
Point-of-care testing in an organ procurement organization donor management setting.
Baier, K A; Markham, L E; Flaigle, S P; Nelson, P W; Shield, C F; Muruve, N A; Aeder, M I; Murillo, D; Bryan, C F
2003-01-01
Our organ procurement organization (OPO) evaluated the clinical and financial efficacy of point-of-care testing (POCT) in management of our deceased organ donors. Before we implemented point-of care testing with the i-STAT into routine clinical donor management, we compared the i-STAT result with the result from the respective donor hospital lab (DHL) for certain analytes on 15 consecutive donors in our OPO from 26 March to 14 May 2001. The financial impact was studied by reviewing 77 donors from July 2001 to March 2002. There was a strong correlation for each analyte between the POC and DHL test results with r-values as follows: pH 0.86; PCO2 = 0.96; PO2 = 0.98; sodium = 0.98; potassium = 0.95; chloride = 0.94; BUN = 0.98; glucose = 0.92; haematocrit = 0.87 and creatinine = 0.95. Since our OPO coordinators began using i-STAT in their routine clinical management of organ donors, they can now more quickly maximize oxygenation and fluid management of the donor and make extra-renal placement calls sooner. Finally, since we are no longer being billed for the testing performed on the i-STAT, average financial savings to our OPO are US dollars 733 per case. Point-of-care testing in management of our OPO donors provides a result that is equivalent to that of the donor hospital lab, has quicker turn-around time than the donor hospital laboratory, allowing more immediate clinical management decisions to be made so that extra-renal offers may begin sooner.
Go, Stephanie L; Lam, Cindy T Y; Lin, Yahui T; Wong, Deborah J; Lazo-Langner, Alejandro; Chin-Yee, Ian
2011-04-01
In Canada, all men who have sex with men (MSM) are indefinitely deferred from donating blood. The purpose of this study was to determine the acceptability of an alternative behavior-based donor health questionnaire among Canadian university students. Further we sought to determine the perception of blood safety associated with specific risk behaviors. Questions found on the Canadian Blood Services' donor health assessment questionnaire as well as from studies assessing high-risk behavior for human immunodeficiency virus infection were included. For each question participants were asked to rate the acceptability, comfort in answering, perceived effect on blood safety, and whether the question would deter them from donating blood. Data were analyzed using nonparametric tests. A total of 741 students participated in the study. Questions regarding sexual practices of the donor were rated less important for blood safety compared to those assessing for sexually transmitted infections, sex for money, and injection drug use (30%-62% vs. 69%-95% unsafe). A total of 24.4% of students rated both questions on MSM status and a behavior-based alternative as equally unacceptable. We found an inverse correlation between perception of safety and acceptability of questions. Our findings suggest that a behavior-based screening modification is unlikely to change opinions or satisfy those who object to the MSM current policy in place. Acceptability of these questions might be related to a poor understanding of the effect of sexual practices on blood supply safety. © 2010 American Association of Blood Banks.
Adu, Patrick; Simpong, David Larbi; Takyi, Godfred; Ephraim, Richard K D
2016-01-01
Background. Blood transfusion is a therapeutic procedure usually undertaken in patients with severe anaemia. In Ghana, severe anaemia is mostly due to malaria caused by severe Plasmodium falciparum infection, road traffic accidents, and haemoglobinopathy-induced acute haemolysis. Method. This cross-sectional study evaluated coinheritance of sickle cell haemoglobin variant and G6PD enzymopathy among individuals that donated blood at the Holy Trinity Hospital, Berekum, in the Brong-Ahafo Region, Ghana. Demographic data and other pertinent information were captured using questionnaire. Sickle cell haemoglobin variants were determined using cellulose acetate electrophoresis (pH 8.6). Qualitative G6PD status and quantitative G6PD enzyme activity were determined using methaemoglobin reduction and Trinity Biotech G6PD test kit, respectively. Results. Prevalence of sickle cell trait (SCT) and G6PD enzymopathy coinheritance was 7%. In addition, 19.5% of the donors had 10%-60% of normal G6PD enzyme activity suggesting that these donor units are prone to stressor-induced acute haemolysis when given to recipients. Mild G6PD activity ( p = 0.03, OR: 2.410 (CI: 1.049-5.534)), commercial ( p = 0.020, OR: 5.609 (CI: 1.309-24.035)), and voluntary ( p = 0.034, OR: 2.404 (CI: 1.071-5.397)) donors were significantly associated with SCT. Conclusion. Screening for red cell pathologies must be incorporated into existing protocols for populations with high incidence of haemoglobinopathies to protect high-risk recipients.
Prevalence of HCV among the young male blood donors of Quetta region of Balochistan, Pakistan
2013-01-01
Background Hepatitis C, caused by hepatitis C virus (HCV) is a contagious disease of the liver which infects more than 170 million people world-wide and around 16 million in Pakistan. HCV associated infection spreads mainly by blood-to-blood contact. In recent years, many studies have been conducted to determine the prevalence of HCV infection in Pakistan; however, no data is available on HCV infection from the largest province of Pakistan. Therefore, the present study focuses on the prevalence of HCV infection in the young male blood donor population of Quetta region of Balochistan, Pakistan. Methods A total of 356 blood samples were collected from blood donors (age range 17–25 years) at Combined Military Hospital (CMH), Quetta, Balochistan, Pakistan. Blood samples were screened for HCV positivity by Immunochromatographic test (ICT) and Enzyme Linked Immunosorbant Assay (ELISA). Results Out of 356 blood samples, the overall HCV prevalence was 20.8%. Among the HCV positive cases, the age group with 25 years was more frequently infected with a prevalence of 26.3%. Conclusions The present study provides the preliminary information about high HCV prevalence among the young male donor population in Balochistan province. This data may be helpful in formulating public health strategy for the prevention of risk factors associated with spreading of the disease. Furthermore, we recommend that in public sector hospitals and health care units ELISA should be preferred for anti-HCV detection over ICT. PMID:23497435
Prevalence of HCV among the young male blood donors of Quetta region of Balochistan, Pakistan.
Khan, Ayesha; Tareen, Abdul Malik; Ikram, Aamer; Rahman, Hazir; Wadood, Abdul; Qasim, Muhammad; Khan, Kalimullah
2013-03-13
Hepatitis C, caused by hepatitis C virus (HCV) is a contagious disease of the liver which infects more than 170 million people world-wide and around 16 million in Pakistan. HCV associated infection spreads mainly by blood-to-blood contact. In recent years, many studies have been conducted to determine the prevalence of HCV infection in Pakistan; however, no data is available on HCV infection from the largest province of Pakistan. Therefore, the present study focuses on the prevalence of HCV infection in the young male blood donor population of Quetta region of Balochistan, Pakistan. A total of 356 blood samples were collected from blood donors (age range 17-25 years) at Combined Military Hospital (CMH), Quetta, Balochistan, Pakistan. Blood samples were screened for HCV positivity by Immunochromatographic test (ICT) and Enzyme Linked Immunosorbant Assay (ELISA). Out of 356 blood samples, the overall HCV prevalence was 20.8%. Among the HCV positive cases, the age group with 25 years was more frequently infected with a prevalence of 26.3%. The present study provides the preliminary information about high HCV prevalence among the young male donor population in Balochistan province. This data may be helpful in formulating public health strategy for the prevention of risk factors associated with spreading of the disease. Furthermore, we recommend that in public sector hospitals and health care units ELISA should be preferred for anti-HCV detection over ICT.
Effects of exposure to factor concentrates containing donations from identified AIDS patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jason, J.; Holman, R.C.; Dixon, G.
1986-10-03
The authors recipients of eight lots of factors VII and IX voluntarily withdrawn from distribution because one donor was known to have subsequently developed the acquired immunodeficiency syndrome with a nonexposed cohort matched by age, sex, and factor use. The factor VIII recipient cohorts did not differ in prevalence of antibody to human immunodeficiency virus (HIV), T-cell subset numbers, T-helper to T-suppressor ratios, or immunogloubulin levels. Exposed individuals had higher levels of immune complexes by C1q binding and staphylococcal binding assays and lower responses to phytohemagglutinin and concanavalin A. However, only the staphylococcal binding assay values were outside the normalmore » range for our laboratory. Factor IX recipient cohorts did not differ in HIV antibody prevalence or any immune tests. Although exposed and nonexposed individuals did not differ from each other in a clinically meaningful fashion at initial testing, both the exposed and nonexposed cohorts had high rats of HIV seroprevalence. Market withdrawals were clearly insufficient means of limiting the spread of HIV in hemophilic patients; however, the currently available methods of donor screening and viral inactivation of blood products will prevent continued exposed within this population.« less
Custer, B; Janssen, M P; Hubben, G; Vermeulen, M; van Hulst, M
2017-08-01
Most countries test donations for HIV, HCV and HBV using serology with or without nucleic acid testing (NAT). Cost-utility analyses provide information on the relative value of different screening options. The aim of this project was to develop an open access risk assessment and cost-utility analysis web-tool for assessing HIV, HCV and HBV screening options (http://www.isbtweb.org/working-parties/transfusion-transmitted-infectious-diseases/). An analysis for six countries (Brazil, Ghana, the Netherlands, South Africa, Thailand and USA) was conducted. Four strategies; (1) antibody assays (Abs) for HIV and HCV + HBsAg, (2) antibody assays that include antigens for HIV and HCV (Combo) + HBsAg, (3) NAT in minipools of variable size (MP NAT) and (4) individual donation (ID) NAT can be evaluated using the tool. Country-specific data on donors, donation testing results, recipient outcomes and costs are entered using the online interface. Results obtained include the number infections interdicted using each screening options, and the (incremental and average) cost-utility of the options. In each of the six countries evaluated, the use of antibody assays is cost effective or even cost saving. NAT has varying cost-utility depending on the setting, and where adopted, the incremental cost-utility exceeds any previously defined or proposed threshold in each country. The web-tool allows an assessment of infectious units interdicted and value for money of different testing strategies. Regardless of gross national income (GNI) per capita, countries appear willing to dedicate healthcare resources to blood supply safety in excess of that for other sectors of health care. © 2017 International Society of Blood Transfusion.
Kidney and liver transplantation in the elderly.
Sutherland, A I; IJzermans, J N M; Forsythe, J L R; Dor, F J M F
2016-01-01
Transplant surgery is facing a shortage of deceased donor organs. In response, the criteria for organ donation have been extended, and an increasing number of organs from older donors are being used. For recipients, the benefits of transplantation are great, and the growing ageing population has led to increasing numbers of elderly patients being accepted for transplantation. The literature was reviewed to investigate the impact of age of donors and recipients in abdominal organ transplantation, and to highlight aspects of the fine balance in donor and recipient selection and screening, as well as allocation policies fair to young and old alike. Overall, kidney and liver transplantation from older deceased donors have good outcomes, but are not as good as those from younger donors. Careful donor selection based on risk indices, and potentially biomarkers, special allocation schemes to match elderly donors with elderly recipients, and vigorous recipient selection, allows good outcomes with increasing age of both donors and recipients. The results of live kidney donation have been excellent for donor and recipient, and there is a trend towards inclusion of older donors. Future strategies, including personalized immunosuppression for older recipients as well as machine preservation and reconditioning of donor organs, are promising ways to improve the outcome of transplantation between older donors and older recipients. Kidney and liver transplantation in the elderly is a clinical reality. Outcomes are good, but can be optimized by using strategies that modify donor risk factors and recipient co-morbidities, and personalized approaches to organ allocation and immunosuppression. © 2015 BJS Society Ltd Published by John Wiley & Sons Ltd.
Musculoskeletal allograft risks and recalls in the United States.
Mroz, Thomas E; Joyce, Michael J; Steinmetz, Michael P; Lieberman, Isador H; Wang, Jeffrey C
2008-10-01
There have been several improvements to the US tissue banking industry over the past decade. Tissue banks had limited active government regulation until 1993, at which time the US Food and Drug Administration began regulatory oversight because of reports of disease transmission from allograft tissues. Reports in recent years of disease transmission associated with the use of allografts have further raised concerns about the safety of such implants. A retrospective review of allograft recall data was performed to analyze allograft recall by tissue type, reason, and year during the period from January 1994 to June 30, 2007. During the study period, more than 96.5% of all allograft tissues recalled were musculoskeletal. The reasons underlying recent musculoskeletal tissue recalls include insufficient or improper donor evaluation, contamination, recipient infection, and positive serologic tests. Infectious disease transmission following allograft implantation may occur if potential donors are not adequately evaluated or screened serologically during the prerecovery phase and if the implant is not sterilized before implantation.
Modrof, Jens; Tille, Björn; Farcet, Maria R; McVey, John; Schreiner, Jessica A; Borders, Charles M; Gudino, Maria; Fitzgerald, Peter; Simon, Toby L; Kreil, Thomas R
2017-11-15
We report a screen of plasma donors confirming that widespread use of childhood measles vaccination since 1963 resulted in a decrease in average measles virus antibody titers among plasma donors, which is reflected in intravenous immunoglobulins (IVIGs). The measles virus antibody titer, however, is a potency requirement for IVIGs, as defined in a Food and Drug Administration regulation. To mitigate the decline in measles virus antibody titers in IVIGs and to ensure consistent product release, revaccination of plasma donors was investigated as a means to boost titers. However, revaccination-induced titer increases were only about 2-fold and short-lived. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Borena, Wegene; Hofer, Tamara; Stiasny, Karin; Aberle, Stephan W; Gaber, Manfred; von Laer, Dorothee; Schennach, Harald
2017-01-01
Previous studies have shown that Zika virus can infect and be transmitted by A. albopictus. The World Health organization (WHO) has raised concerns of autochthonous transmission of the virus in regions where the vector is endemic. The aim of this pilot study was to assess the occurrence of Zika virus (ZIKV) in western Austria (Tyrol) especially after a history of travel to A. albopictus endemic regions. The study participants were healthy blood donors at randomly selected donation sites in the west Austrian region Tyrol. Rest blood (plasma) samples were tested for the presence of ZIKV nucleic acid and antibodies against the virus. Mean age of the study participants was 44.6 (SD = 12.9) and 58.8% were men. Eighty percent reported to have received vaccine against TBEV, whereas only 4.9 and 0.9% had received YFV and JEV vaccines. Three out of 1001 (0.03%) participants tested positive solely for ZIKV IgM antibody but not for other flaviviruses. Only one individual had ZIKV IgG antibody. All four donors were negative in the neutralization (confirmation) assay. No viral RNA was detected in any of the samples. The null finding of our study refutes WHO's initial fear of global expansion of ZIKV infection including its occurrence in Europe. There appears to be no urgent need to introduce universal screening of donated blood for ZIKV in central Europe at least until the next warm season. Further, Euroimmun anti-Zika ELISA proved to be a highly suitable and reliable test system in populations with high prevalence of TBEV infection and/or immunization.
Factors influencing the virological testing of cornea donors.
Röck, Tobias; Beck, Robert; Jürgens, Stefan; Bartz-Schmidt, Karl Ulrich; Bramkamp, Matthias; Thaler, Sebastian; Röck, Daniel
2017-11-01
To assess the influence of donor, environment, and logistical factors on the results of virological testing of blood samples from cornea donors.Data from 670 consecutive cornea donors were analyzed retrospectively. Logistic regression analysis was used to assess the influence of different factors on the results of virological testing of blood samples from cornea donors.The mean annual rate of donors with serology-reactive or not evaluable result was 14.8% (99 of 670) (range 11.9%-16.9%). The cause of donor death by cancer increased the risk of serology-reactive or not evaluable result (P = .0300). Prolonged time between death and post mortem blood removal was associated with a higher rate of serology-reactive or not evaluable result (P < .0001). Mean monthly temperature including warmer months, differentiating between septic and aseptic donors, sex, and donor age had no significant impact on the results of virological testing of blood samples from cornea donors.The cause of donor death by cancer and a prolonged time between death and post mortem blood removal seem to be mainly responsible for serology-reactive or not evaluable result of blood samples from cornea donors. The percentage of discarded corneas caused by serology-reactive or not evaluable result may be reduced by shortening the period of time between death and post mortem blood removal. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Factors influencing the virological testing of cornea donors
Röck, Tobias; Beck, Robert; Jürgens, Stefan; Bartz-Schmidt, Karl Ulrich; Bramkamp, Matthias; Thaler, Sebastian; Röck, Daniel
2017-01-01
Abstract To assess the influence of donor, environment, and logistical factors on the results of virological testing of blood samples from cornea donors. Data from 670 consecutive cornea donors were analyzed retrospectively. Logistic regression analysis was used to assess the influence of different factors on the results of virological testing of blood samples from cornea donors. The mean annual rate of donors with serology-reactive or not evaluable result was 14.8% (99 of 670) (range 11.9%–16.9%). The cause of donor death by cancer increased the risk of serology-reactive or not evaluable result (P = .0300). Prolonged time between death and post mortem blood removal was associated with a higher rate of serology-reactive or not evaluable result (P < .0001). Mean monthly temperature including warmer months, differentiating between septic and aseptic donors, sex, and donor age had no significant impact on the results of virological testing of blood samples from cornea donors. The cause of donor death by cancer and a prolonged time between death and post mortem blood removal seem to be mainly responsible for serology-reactive or not evaluable result of blood samples from cornea donors. The percentage of discarded corneas caused by serology-reactive or not evaluable result may be reduced by shortening the period of time between death and post mortem blood removal. PMID:29381929
Vitrenko, Yakov; Kostenko, Iryna; Kulebyakina, Kateryna; Sorochynska, Khrystyna
2017-08-31
Human pegivirus-1 (HPgV-1) is a member of the Flaviviridae family whose genomic organization and mode of cellular entry is similar to that of hepatitis C virus (HCV). The E2 glycoprotein of HPgV-1 is the principle mediator in the virus-cell interaction and as such harbors most of HPgV-1's antigenic determinants. HPgV-1 persists in blood cell precursors which are increasingly used for cell therapy. We studied HPgV-1 prevalence in a large cohort of females donating fetal tissues for clinical use. PCR was used for screening and estimation of viral load in viremic plasma and fetal samples. Sequence analysis was performed for portions of the 5'-untranslated and E2 regions of HPgV-1 purified from donor plasmas. Sequencing was followed by phylogenetic analysis. HPgV-1 was revealed in 13.7% of plasmas, 5.0% of fetal tissues, 5.4% of chorions, exceeding the prevalence of HCV in these types of samples. Transmission of HPgV-1 occurred in 25.8% of traceable mother-chorion-fetal tissues triads. For HPgV-1-positive donors, a high viral load in plasma appears to be a prerequisite for transmission. However, about one third of fetal samples acquired infection from non-viremic individuals. Sequencing of 5'-untranslated region placed most HPgV-1 samples to genotype 2a. At the same time, a portion of E2 sequence provided a much weaker support for this grouping apparently due to a higher variability. Polymorphisms were detected in important structural and antigenic motifs of E2. HPgV-1 is efficiently transmitted to fetus at early embryonic stages. A high variability in E2 may pose a risk of generation of pathogenic subtypes. Although HPgV-1 is considered benign and no longer tested mandatorily in blood banks, the virus may have adversary effects at target niches if delivered with infected graft upon cell transplantation. This argues for the necessity of HPgV-1 testing of cell samples aimed for clinical use.
Clinical and immunological relevance of antibodies in solid organ transplantation.
Mehra, N K; Baranwal, A K
2016-12-01
The two important issues affecting recipients of solid organ transplants and of importance to immunologists are (i) sensitization of the recipient to HLA antigens and the resultant humoral immune response leading to the development of anti-HLA antibodies; and ii) development of robust assays for early detection of humoral rejection post-transplant. Evidence from several studies clearly indicates that presence of circulating anti-HLA antibodies especially donor specific leads to early graft loss and high titres of DSA may even lead to hyperacute or accelerated acute rejection. Long-term graft survival too is adversely affected by the presence of either pre- or post-transplant DSA. HLA matching status of the recipient - donor pair - is an important factor in the modulation of humoral response following transplantation and in a way affects de novo development of DSA. Data collected over the past decade clearly indicate significantly lower level of DSAs in optimally matched donor-recipient pairs. HLA mismatches especially those on HLA-DR and HLA-C loci have wider implications on post-transplant graft survival. The presence of circulating anti-HLA antibodies leads to endothelial damage in the newly grafted organ through complement dependent or independent pathways. Although detection of C4d deposition in renal biopsies serves as an important indicator of humoral rejection, its absence does not preclude the presence of DSAs and humoral rejection, and hence, it cannot be relied upon in every case. The emergence of epitope-based screening for anti-HLA antibodies on Luminex platform with high degree of sensitivity has revolutionized the screening for anti-HLA antibodies and DSAs. Studies indicate that humoral response to non-HLA antigens might also have a detrimental effect on allograft survival. High titres of such circulating antibodies may even lead to hyperacute rejection. Pre-emptive testing of solid organ recipients, especially kidney transplant recipients for anti-HLA and non-HLA antibodies and aggressive post-transplant monitoring of allograft function to detect DSAs using Luminex-based tests, is highly recommended. © 2016 John Wiley & Sons Ltd.
Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L
2007-01-01
Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958
Babanejad, Mehran; Izadi, Neda; Najafi, Farid; Alavian, Seyed Moayed
2016-03-01
The world health organization (WHO) recommends that all blood donations should be screened for evidence of infections, such as hepatitis B. The present study aimed to determine the prevalence of hepatitis B surface antigen (HBsAg) in blood donors at the eastern Mediterranean region office (EMRO) of the WHO and middle eastern countries. A meta-analysis was carried out based on the results of an electronic literature search of PubMed, Ovid, Scopus, and Google Scholar for articles published from January 1, 2000, to August 31, 2015. In accordance with a significant homogeneity test and a large value of I2, the random effects model was used to aggregate data from the studies and produce the pooled estimates using the "Metan" command. We included 66 eligible studies. The pooled prevalence of HBsAg in blood donors of both EMRO and middle eastern (E and M) countries was 2.03% (95% confidence interval [CI]: 1.79 - 2.26). In addition, the prevalence rates in the EMRO countries was 1.99% (95% CI: 1.84 - 2.14) and 1.62% in the Middle Eastern countries (95% CI: 1.36 - 1.88). The prevalence among blood donors with more than one study was 1.58% in Egypt, 0.58% in Iran, 0.67% in Iraq, 2.84% in Pakistan, 3.02% in Saudi Arabia, 1.68% in Turkey, and 5.05% in Yemen. Based on the WHO classification of hepatitis B virus (HBV) prevalence, the prevalence of HBsAg in blood donors from E and M countries reached an intermediate level. However, there were low prevalence levels in some E and M countries.
Motivation and Social Capital among prospective blood donors in three large blood centers in Brazil
Gonçalez, Thelma T.; Di Lorenzo Oliveira, Claudia; Carneiro-Proietti, Anna Barbara F.; Moreno, Elizabeth C.; Miranda, Carolina; Larsen, Nina; Wright, David; Leão, Silvana; Loureiro, Paula; de Almeida-Neto, Cesar; Lopes, Maria-Inês; Proietti, Fernando A.; Custer, Brian; Sabino, Ester
2012-01-01
Background Studies analyzing motivation factors that lead to blood donation have found altruism to be the primary motivation factor; however social capital has not been analyzed in this context. Our study examines the association between motivation factors (altruism, self-interest and response to direct appeal) and social capital (cognitive and structural) across three large blood centers in Brazil. Study Design and Methods We conducted a cross-sectional survey of 7,635 donor candidates from October 15 through November 20, 2009. Participants completed self-administered questionnaires on demographics, previous blood donation, HIV testing and knowledge, social capital and donor motivations. Enrollment was determined prior to the donor screening process. Results Among participants, 43.5% and 41.7% expressed high levels of altruism and response to direct appeal respectively, while only 26.9% expressed high levels of self-interest. More high self-interest was observed at Hemope-Recife (41.7%). Of participants, 37.4% expressed high levels of cognitive social capital while 19.2% expressed high levels of structural social capital. More high cognitive and structural social capital was observed at Hemope-Recife (47.3% and 21.3%, respectively). High cognitive social capital was associated with high levels of altruism, self-interest and response to direct appeal. Philanthropic and high social altruism was associated with high levels of altruism and response to direct appeal. Conclusion Cognitive and structural social capital and social altruism are associated with altruism and response to direct appeal, while only cognitive social capital is associated with self-interest. Designing marketing campaigns with these aspects in mind may help blood banks attract potential blood donors more efficiently. PMID:22998740
Motivation and social capital among prospective blood donors in three large blood centers in Brazil.
Gonçalez, Thelma T; Di Lorenzo Oliveira, Claudia; Carneiro-Proietti, Anna Barbara F; Moreno, Elizabeth C; Miranda, Carolina; Larsen, Nina; Wright, David; Leão, Silvana; Loureiro, Paula; de Almeida-Neto, Cesar; Lopes, Maria-Inês; Proietti, Fernando A; Custer, Brian; Sabino, Ester
2013-06-01
Studies analyzing motivation factors that lead to blood donation have found altruism to be the primary motivation factor; however, social capital has not been analyzed in this context. Our study examines the association between motivation factors (altruism, self-interest, and response to direct appeal) and social capital (cognitive and structural) across three large blood centers in Brazil. We conducted a cross-sectional survey of 7635 donor candidates from October 15 through November 20, 2009. Participants completed self-administered questionnaires on demographics, previous blood donation, human immunodeficiency virus testing and knowledge, social capital, and donor motivations. Enrollment was determined before the donor screening process. Among participants, 43.5 and 41.7% expressed high levels of altruism and response to direct appeal, respectively, while only 26.9% expressed high levels of self-interest. More high self-interest was observed at Hemope-Recife (41.7%). Of participants, 37.4% expressed high levels of cognitive social capital while 19.2% expressed high levels of structural social capital. More high cognitive and structural social capital was observed at Hemope-Recife (47.3 and 21.3%, respectively). High cognitive social capital was associated with high levels of altruism, self-interest, and response to direct appeal. Philanthropic and high social altruism were associated with high levels of altruism and response to direct appeal. Cognitive and structural social capital and social altruism are associated with altruism and response to direct appeal, while only cognitive social capital is associated with self-interest. Designing marketing campaigns with these aspects in mind may help blood banks attract potential blood donors more efficiently. © 2012 American Association of Blood Banks.
Haberal, Kemal Murat; Turnaoğlu, Hale; Özdemir, Adnan; Uslu, Nihal; Haberal Reyhan, Asuman Nihan; Moray, Gökhan; Haberal, Mehmet
2017-08-24
The aim of this study was to evaluate the diagnostic efficiency of the acoustic radiation force impulse (Siemens Medical Solutions, Erlangen, Germany) elastography in assessment of fibrosis in orthotopic liver transplant patients. We enrolled 28 orthotopic liver transplant patients (deceased and living donors), whose biopsy decision had been prospectively given clinically. Ten acoustic radiation force impulse elastographic measurements were applied before the biopsy or within 3 days after the biopsy by 2 radiologists. After the core tissue needle biopsy, specimens of all patients were analyzed according to the modified Ishak scoring system. Measurements of acoustic radiation force impulse elastography and pathology specimen results were compared. From 28 biopsies, fibrosis scores of 4 biopsies were evaluated as F0 (14.3%), 16 as F1 (57.1%), 4 as F2 (14.3%), and 4 as F3 (14.3%). Mean results of acoustic radiation force impulse measurements were calculated as 1.4 ± 0.07 in F0, 1.74 ± 0.57 in F1, 2.19 ± 0.7 in F2, and 2.18 ± 0.35 in F3. There were no significant correlations of mean acoustic radiation force impulse values between the F0 versus F1 (P = .956) and F0 versus F2 stages (P = .234). A statistically significant correlation of mean acoustic radiation force impulse values was found between the F0 and F3 fibrosis stages (P = .046). Acoustic radiation force impulse imaging is a promising screening test for detecting significant liver fibrosis (≥ F3 in modified Ishak) in living-donor or deceased-donor orthotopic liver transplant recipients.
Hepatitis E and blood donation safety in selected European countries: a shift to screening?
Domanović, Dragoslav; Tedder, Richard; Blümel, Johannes; Zaaijer, Hans; Gallian, Pierre; Niederhauser, Christoph; Sauleda Oliveras, Silvia; O’Riordan, Joan; Boland, Fiona; Harritshøj, Lene; Nascimento, Maria São José; Ciccaglione, Anna Rita; Politis, Constatina; Adlhoch, Cornelia; Flan, Benoit; Oualikene-Gonin, Wahiba; Rautmann, Guy; Strengers, Paul; Hewitt, Patricia
2017-01-01
The public health implications of hepatitis E virus (HEV) in Europe have changed due to increasing numbers of hepatitis E cases and recent reports of chronic, persistent HEV infections associated with progression to cirrhosis in immunosuppressed patients. The main infectious risk for such immunosuppressed patients is exposure to undercooked infected pork products and blood transfusion. We summarised the epidemiology of HEV infections among blood donors and also outlined any strategies to prevent transfusion-transmitted HEV, in 11 European countries. In response to the threat posed by HEV and related public and political concerns, most of the observed countries determined seroprevalence of HEV in donors and presence of HEV RNA in blood donations. France, Germany, Spain and the United Kingdom (UK) reported cases of transfusion-transmitted HEV. Ireland and the UK have already implemented HEV RNA screening of blood donations; the Netherlands will start in 2017. Germany and France perform screening for HEV RNA in several blood establishments or plasma donations intended for use in high-risk patients respectively and, with Switzerland, are considering implementing selective or universal screening nationwide. In Greece, Portugal, Italy and Spain, the blood authorities are evaluating the situation. Denmark decided not to implement the HEV screening of blood donations. PMID:28449730
Hepatitis E and blood donation safety in selected European countries: a shift to screening?
Domanović, Dragoslav; Tedder, Richard; Blümel, Johannes; Zaaijer, Hans; Gallian, Pierre; Niederhauser, Christoph; Sauleda Oliveras, Silvia; O'Riordan, Joan; Boland, Fiona; Harritshøj, Lene; Nascimento, Maria São José; Ciccaglione, Anna Rita; Politis, Constatina; Adlhoch, Cornelia; Flan, Benoit; Oualikene-Gonin, Wahiba; Rautmann, Guy; Strengers, Paul; Hewitt, Patricia
2017-04-20
The public health implications of hepatitis E virus (HEV) in Europe have changed due to increasing numbers of hepatitis E cases and recent reports of chronic, persistent HEV infections associated with progression to cirrhosis in immunosuppressed patients. The main infectious risk for such immunosuppressed patients is exposure to undercooked infected pork products and blood transfusion. We summarised the epidemiology of HEV infections among blood donors and also outlined any strategies to prevent transfusion-transmitted HEV, in 11 European countries. In response to the threat posed by HEV and related public and political concerns, most of the observed countries determined seroprevalence of HEV in donors and presence of HEV RNA in blood donations. France, Germany, Spain and the United Kingdom (UK) reported cases of transfusion-transmitted HEV. Ireland and the UK have already implemented HEV RNA screening of blood donations; the Netherlands will start in 2017. Germany and France perform screening for HEV RNA in several blood establishments or plasma donations intended for use in high-risk patients respectively and, with Switzerland, are considering implementing selective or universal screening nationwide. In Greece, Portugal, Italy and Spain, the blood authorities are evaluating the situation. Denmark decided not to implement the HEV screening of blood donations. This article is copyright of The Authors, 2017.
Bruhn, Roberta; Lelie, Nico; Custer, Brian; Busch, Michael; Kleinman, Steven
2013-10-01
Twenty-one blood organizations from five geographical regions provided HIV individual donation (ID)-NAT and serology data on 11,787,610 donations. Infections were classified as anti-HIV-/RNA+ window period (WP), anti-HIV+/RNA+ concordant positive (CP) or anti-HIV+/RNA- elite controller (EC). Residual risk and efficacy of several screening scenarios were estimated for first time, lapsed and repeat donations. WP residual risk estimates assumed a 50% infectious dose of 3.16 virions and a 50% detection limit of 2.7 HIV RNA copies/mL for ID-NAT and 10,000 copies/mL for p24Ag. Infectivity for CP (100%) and EC (2.2%) donations was estimated based on viral load distributions and 100-fold reduced infectivity by antibody neutralization as reported elsewhere. Efficacy was calculated as proportion of transmission risk removed from baseline (i.e. in absence of any screening). There was no significant difference in transmission risk between lapsed and repeat donations in any region. Risk was 3.8-fold higher in first time than combined lapsed/repeat donations in South Africa but not in other regions. Screening strategies were most efficacious at interdicting infectious transfusions in first time (98.7-99.8%) followed by lapsed (97.6-99.7%) and repeat (86.8-97.7%) donations in all regions combined. In each donor category the efficacy of ID-NAT alone (97.7-99.8%) was superior to that of minipool (MP)-NAT/anti-HIV (95.0-99.6%) and p24 Ag/anti-HIV (89.8-99.1%). Efficacy patterns were similar by donor/donation status in each region despite large differences in HIV prevalence and transmission risk. As similar data become available for HBV and HCV, this modeling may be useful in cost effectiveness analyses of alternative testing scenarios. © 2013 American Association of Blood Banks.
Zika virus epidemiology in Bolivia: A seroprevalence study in volunteer blood donors.
Saba Villarroel, Paola Mariela; Nurtop, Elif; Pastorino, Boris; Roca, Yelin; Drexler, Jan Felix; Gallian, Pierre; Jaenisch, Thomas; Leparc-Goffart, Isabelle; Priet, Stéphane; Ninove, Laetitia; de Lamballerie, Xavier
2018-03-01
Zika virus (ZIKV), was widely reported in Latin America and has been associated with neuropathologies, as microcephaly, but only few seroprevalence studies have been published to date. Our objective was to determine the seroprevalence amongst Bolivian blood donors and estimate the future potential circulation of the virus. A ZIKV seroprevalence study was conducted between December 2016 and April 2017 in 814 asymptomatic Bolivian volunteer blood donors residing in various eco-environments corresponding to contrasting entomological activities. It was based on detection of IgG to ZIKV using NS1 ELISA screening, followed by a seroneutralisation test in case of positive or equivocal ELISA result. Analysis revealed that ZIKV circulation occurred in tropical areas (Beni: 39%; Santa Cruz de la Sierra: 21.5%) but not in highlands (~0% in Cochabamba, La Paz, Tarija). It was modulated by Aedes aegypti activity and the virus spread was not limited by previous immunity to dengue. Cases were geo-localised in a wide range of urban areas in Santa Cruz and Trinidad. No differences in seroprevalence related to gender or age-groups could be identified. It is concluded that ZIKV has been intensely circulating in the Beni region and has still a significant potential for propagating in the area of Santa Cruz.
Zika virus epidemiology in Bolivia: A seroprevalence study in volunteer blood donors
Nurtop, Elif; Pastorino, Boris; Roca, Yelin; Drexler, Jan Felix; Gallian, Pierre; Jaenisch, Thomas; Leparc-Goffart, Isabelle; Priet, Stéphane; Ninove, Laetitia; de Lamballerie, Xavier
2018-01-01
Background Zika virus (ZIKV), was widely reported in Latin America and has been associated with neuropathologies, as microcephaly, but only few seroprevalence studies have been published to date. Our objective was to determine the seroprevalence amongst Bolivian blood donors and estimate the future potential circulation of the virus. Methodology A ZIKV seroprevalence study was conducted between December 2016 and April 2017 in 814 asymptomatic Bolivian volunteer blood donors residing in various eco-environments corresponding to contrasting entomological activities. It was based on detection of IgG to ZIKV using NS1 ELISA screening, followed by a seroneutralisation test in case of positive or equivocal ELISA result. Conclusions/Significance Analysis revealed that ZIKV circulation occurred in tropical areas (Beni: 39%; Santa Cruz de la Sierra: 21.5%) but not in highlands (~0% in Cochabamba, La Paz, Tarija). It was modulated by Aedes aegypti activity and the virus spread was not limited by previous immunity to dengue. Cases were geo-localised in a wide range of urban areas in Santa Cruz and Trinidad. No differences in seroprevalence related to gender or age-groups could be identified. It is concluded that ZIKV has been intensely circulating in the Beni region and has still a significant potential for propagating in the area of Santa Cruz. PMID:29513667
ABO and rhesus antigens in a cosmopolitan Nigeria population.
Nwauche, C A; Ejele, O A
2004-01-01
Port Harcourt is a cosmopolitan city consisting of several ethnic groupings such as Ikwerre, Ijaw, Igbo, Ogonis, Efik-Ibibio, Edo, Yoruba, Hausa and foreign nationals. ABO and Rhesus D antigens were screened in this cross-sectional study with the aim of generating data that would assist in the running of an efficient blood transfusion service for a cosmopolitan city as Port Harcourt. Blood donors were sampled and screened for ABO and Rhesus D antigens at three Health facilities within Port Harcourt: University of Port Harcourt Teaching Hospital, Braithwaite Memorial Hospital and Orogbum Health centre. A total of 936 blood donors were tested in this study. The results of the ABO screening shows that blood group O was the highest with 527 (56.30%) followed by blood group A, B and lastly AB with 212 (22.65%), 178 (19.02%) and 18(2.10%) respectively. The highest contribution to blood group O was from the Ibos with 220 (23.50%) while the Ijaws gave the highest contribution of Rhesus "D" antigen with 370 (39.53%), closely followed by the Igbos with 334 (0.43%). Rhesus negativity values in this study was 7.26% of which the highest contributors were also the Ijaws with 33 (3.53%) and Igbos with 27(2.89%). The increased demand for safe blood calls for an efficient Blood, Transfusion Service at the local, state and national levels. It is hoped that the data generated in this study would assist in the planning and establishment of a functional Blood service that would not only meet the ever increasing demand for blood products, but also play a vital role in the control of HIV/AIDS and . Hepatitis B global scourge.
Gap Test Calibrations and Their Scaling
NASA Astrophysics Data System (ADS)
Sandusky, Harold
2011-06-01
Common tests for measuring the threshold for shock initiation are the NOL large scale gap test (LSGT) with a 50.8-mm diameter donor/gap and the expanded large scale gap test (ELSGT) with a 95.3-mm diameter donor/gap. Despite the same specifications for the explosive donor and polymethyl methacrylate (PMMA) gap in both tests, calibration of shock pressure in the gap versus distance from the donor scales by a factor of 1.75, not the 1.875 difference in their sizes. Recently reported model calculations suggest that the scaling discrepancy results from the viscoelastic properties of PMMA in combination with different methods for obtaining shock pressure. This is supported by the consistent scaling of these donors when calibrated in water-filled aquariums. Calibrations with water gaps will be provided and compared with PMMA gaps. Scaling for other donor systems will also be provided. Shock initiation data with water gaps will be reviewed.
Risk factors for retrovirus and hepatitis virus infections in accepted blood donors.
Custer, Brian; Kessler, Debra; Vahidnia, Farnaz; Leparc, German; Krysztof, David E; Shaz, Beth; Kamel, Hany; Glynn, Simone; Dodd, Roger Y; Stramer, Susan L
2015-05-01
Risk factor surveillance among infected blood donors provides information on the effectiveness of eligibility assessment and is critical for reducing risk of transfusion-transmitted infection. American Red Cross, Blood Systems, Inc., New York Blood Center, and OneBlood participated in a case-control study from 2010 to 2013. Donors with serologic and nucleic acid testing (NAT) or NAT-only confirmed human immunodeficiency virus (HIV), hepatitis B virus (HBV), hepatitis C virus (HCV), or serology-confirmed human T-lymphotropic virus (HTLV) infections (cases) and donors with false-positive results (controls) were interviewed for putative behavioral and demographic risks. Frequencies and adjusted odds ratios (AORs) from multivariable logistic regression analyses for each exposure in cases compared to controls are reported. In the study, 196 HIV, 292 HBV, 316 HCV, and 198 HTLV cases, and 1587 controls were interviewed. For HIV, sex with an HIV+ person (AOR, 132; 95% confidence interval [CI], 27-650) and male-male sex (AOR, 62; 95% CI, 27-140) were primary risk factors. For HBV, first-time donor status (AOR, 16; 95% CI, 10-27), sex with an injection drug user (IDU; AOR, 11; 95% CI, 5-28), and black race (AOR, 11; 95% CI, 6-19) were primary. For HCV, IDU (AOR, 42; 95% CI, 13-136), first time (AOR, 18; 95% CI, 10-30), and a family member with hepatitis (AOR, 15; 95% CI, 6-40) were primary. For HTLV, sex with an IDU (AOR, 22; 95% CI, 10-48), 55 years old or more (AOR, 21; 95% CI, 8-52], and first time (AOR, 15; 95% CI, 9-24) were primary. Despite education efforts and risk screening, individuals with deferrable risks still donate; they may fail to understand or ignore or do not believe they have risk. Recipients have potential transfusion-transmitted infection risk because of nondisclosure by donors. © 2014 AABB.
Nébié, Koumpingnin; Ouattara, Siaka; Sanou, Mahamoudou; Kientega, Youssouphe; Dahourou, Honorine; Ky, Lassina; Kienou, Kisito; Diallo, Samba; Bigirimana, Françoise; Fretz, Catherine; Murphy, Edward L.; Lefrère, Jean-Jacques
2011-01-01
Introduction The World Health Organization (WHO) recommends the creation of national blood transfusion services. Burkina Faso has a CNTS (Centre national de transfusion sanguine - National Blood Transfusion Center) but it currently covers only 53% of the national blood supply versus 47% produced by independent hospital blood banks. Study design To evaluate blood collection, testing, preparation and prescription practices in the regions of Burkina Faso that are not covered by the CNTS, we conducted a cross-sectional survey. Methodology Data were collected by trained professionals from May to June 2009, at 42 autonomous blood centers not covered by the CNTS. Results Blood collection was supervised in all sites by laboratory technicians without specific training. There was no marketing of community blood donation nor mobile collection. Donation was restricted to replacement (family) donors in 21.4% of sites. Pre-donation screening of donors was performed in 63.4% of sites, but some did not use written questionnaires. Testing for HIV, hepatitis B virus and syphilis was universal, although some sites did not screen for hepatitis C virus. In 83.3% of the sites blood typing was performed without reverse ABO typing. In 97.6% of the sites, nurses acted alone or in conjunction with a physician to order blood transfusions. Conclusion Shortcomings in non-CNTS blood centers argue for the development of a truly national CNTS. Such a national center should coordinate and supervise all blood transfusion activities, and is the essential first step for improving and institutionalizing blood transfusion safety and efficacy in a developing country. PMID:21736582
Ware, A D; Jacquot, C; Tobian, A A R; Gehrie, E A; Ness, P M; Bloch, E M
2018-01-01
Transfusion-transmitted infection risk remains an enduring challenge to blood safety in Africa. A high background incidence and prevalence of the major transfusion-transmitted infections (TTIs), dependence on high-risk donors to meet demand, suboptimal testing and quality assurance collectively contribute to the increased risk. With few exceptions, donor testing is confined to serological evaluation of human immunodeficiency virus (HIV), hepatitis B and C (HBV and HCV) and syphilis. Barriers to implementation of broader molecular methods include cost, limited infrastructure and lack of technical expertise. Pathogen reduction (PR), a term used to describe a variety of methods (e.g. solvent detergent treatment or photochemical activation) that may be applied to blood following collection, offers the means to diminish the infectious potential of multiple pathogens simultaneously. This is effective against different classes of pathogen, including the major TTIs where laboratory screening is already implemented (e.g. HIV, HBV and HCV) as well pathogens that are widely endemic yet remain unaddressed (e.g. malaria, bacterial contamination). We sought to review the available and emerging PR techniques and their potential application to resource-constrained parts of Africa, focusing on the advantages and disadvantages of such technologies. PR has been slow to be adopted even in high-income countries, primarily given the high costs of use. Logistical considerations, particularly in low-resourced parts of Africa, also raise concerns about practicality. Nonetheless, PR offers a rational, innovative strategy to contend with TTIs; technologies in development may well present a viable complement or even alternative to targeted screening in the future. © 2017 International Society of Blood Transfusion.
Mbugua, Amos; Maturi, Peter; Rajab, Jamila; Blasczyk, Rainer; Heuft, Hans-Gert
2015-01-01
Background Currently, no data are available on the prevalence of red blood cell (RBC) antibody formation amongst Kenyan patients with multiple transfusion needs, such as patients with sickle cell disease (SCD) or haematological malignancies (HM) and solid (SM) malignancies. Objectives We determined the prevalence and specificities of RBC alloantibodies and autoantibodies in two patient groups with recurrent transfusion demands at Kenyatta National Hospital, Nairobi, Kenya. Method Between February and August 2014, 300 samples from SCD, HM and SM patients were collected and screened for alloantibodies. Samples from 51 healthy blood donors were screened for irregular antibodies and phenotyped. Results Amongst the 228 patients with viable samples (SCD, n = 137; HM, n = 48; SM, n = 43), the median transfusion frequency was two to three events per group, 38 (16.7%) were RBC immunised and 32 (14.0%) had a positive direct antiglobulin test. We identified specific alloantibodies in six patients (2.6%). Four of these six were SCD patients (2.9%) who had specific RBC alloantibodies (anti-Cw, anti-M, anti-Cob, anti-S); amongst HM patients one had anti-K and one had anti-Lea. RBC autoantibody prevalence was 3.1% (7/228). Amongst the healthy blood donors, the Ror, ccD.ee and R2r, ccD.Ee phenotypes accounted for 82% of the Rhesus phenotypes and all were Kell negative. Conclusion The numbers of transfusions and the rates of RBC alloantibodies are low and the most important RBC alloantibody-inducing blood group antigens are relatively homogeneously distributed in this population. A general change in the Kenyatta National Hospital pre-transfusion test regimen is thus not necessary. The current transfusion practice should be reconsidered if transfusion frequencies increase in the future. PMID:28879098
Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H; Watkins, Scott E; Kim, Dong-Yu; Vak, Doojin
2016-02-08
We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%.
Jung, Yen-Sook; Hwang, Kyeongil; Scholes, Fiona H.; Watkins, Scott E.; Kim, Dong-Yu; Vak, Doojin
2016-01-01
We report a spray deposition technique as a screening tool for solution processed solar cells. A dual-feed spray nozzle is introduced to deposit donor and acceptor materials separately and to form blended films on substrates in situ. Using a differential pump system with a motorised spray nozzle, the effect of film thickness, solution flow rates and the blend ratio of donor and acceptor materials on device performance can be found in a single experiment. Using this method, polymer solar cells based on poly(3-hexylthiophene) (P3HT):(6,6)-phenyl C61 butyric acid methyl ester (PC61BM) are fabricated with numerous combinations of thicknesses and blend ratios. Results obtained from this technique show that the optimum ratio of materials is consistent with previously reported values confirming this technique is a very useful and effective screening method. This high throughput screening method is also used in a single-feed configuration. In the single-feed mode, methylammonium iodide solution is deposited on lead iodide films to create a photoactive layer of perovskite solar cells. Devices featuring a perovskite layer fabricated by this spray process demonstrated a power conversion efficiencies of up to 7.9%. PMID:26853266
Mycobacteria and allograft heart valve banking: an international survey.
Warwick, R M; Magee, J G; Leeming, J P; Graham, J C; Hannan, M M; Chadwick, M; Crook, D W; Yearsley, C P; Rayner, A; Parker, R
2008-03-01
Since the 1970s many tissue banks have been testing allograft heart valves (HVs) for Mycobacterium tuberculosis (MTB). Donor selection for low risk of tuberculosis (TB) was introduced in the 1980s and appears to have reduced the risk of TB transmission. Regulatory guidance does not specify testing for TB, but does exclude donors with a recent history of TB. This survey of HV international bank practices revealed variations in donor selection, testing and processing of valves. Participant banks (from Europe and the USA) reported that over a period of 15 years, HV tissues from 38,413 donors were banked and 32,289 donors were tested for TB, none being positive. HV-associated tissue from 27,840 donors was stained and underwent microscopy; none of these were positive for acid-fast bacilli (AFB). Non-tuberculosis mycobacteria (NTBM) were detected by culture on 24 HVs. It is recommended that HV banks employ donor selection to exclude donors at risk of TB, to culture material for mycobacteria, and to investigate potential sources when clusters of NTBM are found to facilitate corrective and preventative actions.
Metabolomics of AS-1 RBC storage
Roback, John D.; Josephson, Cassandra D.; Waller, Edmund K.; Newman, James L.; Karatela, Sulaiman; Uppal, Karan; Jones, Dean; Zimring, James C.; Dumont, Larry J.
2014-01-01
Background Population based investigations suggest that red blood cells (RBCs) are therapeutically effective when collected, processed and stored for up to 42 days under validated conditions prior to transfusion. However, some retrospective clinical studies have shown worse patient outcomes when transfused RBCs have been stored for the longest times. Furthermore, studies of RBC persistence in the circulation after transfusion have suggested that considerable donor-to-donor variability exists, and may affect transfusion efficacy. To understand the limitations of current blood storage technologies and to develop approaches to improve RBC storage and transfusion efficacy, we investigated the global metabolic alterations that occur when RBCs are stored in AS-1 (AS1-RBC). Methods Leukoreduced AS1-RBC units prepared from 9 volunteer research donors (12 total donated units) were serially sampled for metabolomics analysis over 42 days of refrigerated storage. Samples were tested by GC/MS and LC/MS/MS, and specific biochemical compounds were identified by comparison to a library of purified standards. Results Over three experiments, 185–264 defined metabolites were quantified in stored RBC samples. Kinetic changes in these biochemicals confirmed known alterations in glycolysis and other pathways previously identified in RBCs stored in SAGM (SAGM-RBC). Furthermore, we identified additional alterations not previously seen in SAGM-RBCs (e.g., stable pentose phosphate pathway flux, progressive decreases in oxidized glutathione), and we delineated changes occurring in other metabolic pathways not previously studied (e.g., S-adenosyl methionine cycle). These data are presented in the context of a detailed comparison with previous studies of SAGM-RBCs from human donors and murine AS1-RBCs. Conclusion Global metabolic profiling of AS1-RBCs revealed a number of biochemical alterations in stored blood that may affect RBC viability during storage as well as therapeutic effectiveness of stored RBCs in transfusion recipients. Significance These results provide future opportunities to more clearly pinpoint the metabolic defects during RBC storage, to identify biomarkers for donor screening and prerelease RBC testing, and to develop improved RBC storage solutions and methodologies. PMID:24636780
Mishra, Swechha; Singh, Sangeeta
2017-01-01
Background: In experimental therapy of cancer, survivin is considered to be one of the well-established targets. Studies have found that it is overexpression in most of the human tumors, but it is rarely found in normal tissues. It is having varied structural and functional role. It controls cell division and cellular stress response and also regulates metastasis and migration of cancerous cells. It has also been recognized as a biomarker which makes it unconventional drug target. In spite of being one of the centrally active components in metastasis and invasion, their clinical use is minimal. To increase the therapeutic efficiency of cancer and its various stages, it is important to survey novel reagents targeting the pathways and mechanism involving survivin. Objective: The aim of this study was to identify novel survivin inhibitor candidates using in silico screening. Materials and Methods: In this course of work, virtual screening on a dataset of natural compounds retrieved from ZINC and other libraries were performed. Comparative analysis of the protein was done by studying the binding affinity of inhibitors that are already available. The best interacting complex was set for molecular dynamics simulation for 25 ns to validate the stability of system. These molecules were checked for their toxicity and absorption, distribution, metabolism, excretion, and toxicity (ADMET) properties using OSIRIS and pre-ADMET tools. Results: We discovered ten such candidates with better binding efficiency with survivin in comparison to marketed chemical against the same. Furthermore, these inhibitor candidates did not induce cell toxicity. Binding affinity of reference molecules was varied from −6.8 to −8.5 kcal/mol while that of top scoring compound ZINC00689728 is −9.3 kcal/mol binding energy. Good placement and strong bond formation of selected molecule was observed during course of work. It is also having permissible ADMET property. Conclusion: Considering all the parameters, the screened molecule can be considered as a potential lead compound for designing new drug against survivin. Further investigation and testing will be required to make it to the final stage. SUMMARY Survivin is one of the important protein of metastasis. Inhibiting survivin might led to the increased therapeutic efficiency of cancer. In this work we are screening library of natural compounds in view of finding some potent inhibitor against survivin. Abbreviations used: MD: Molecular dynamics, LogS: Aqueous solubility, Acceptor HB: Hydrogen bond acceptor, Donor HB: Donor hydrogen bond donor, ADMET: Absorption, distribution, metabolism, excretion, and toxicity, RCSB: Research Collaboratory for Structural Bioinformatics, OPLS: Optimized potentials for liquid simulations, RMSD: Root-mean-square deviation. PMID:29491627
Guldager, Daniel Kring Rasmussen; von Stemann, Jakob Hjorth; Larsen, Rune; Bay, Jakob Thaning; Galle, Pia Søndergaard; Svenson, Morten; Ullum, Henrik; Hansen, Morten Bagge
2015-10-01
To establish and validate a rapid, cost-effective and accurate screening assay for the simultaneous testing of human naturally occurring anti-cytokine autoantibodies (c-aAb) targeting interleukin-1α (IL-1α), interleukin-6 (IL-6), interleukin-10 (IL-10), granulocyte-macrophage colony-stimulating factor (GM-CSF), and interferon α (IFNα). Because the c-aAbs can be transferred to patients through blood transfusion, the assay was used to assess c-aAb levels in a cohort of patients who were receiving blood transfusions and subsequently presented with or without febrile reactions. The microsphere-based Luminex platform was used. Recombinant forms of human IL-1α, IL-6, IL-10, GM-CSF, and IFNα were gently coupled to MAG-PLEX beads. Plasma IgG binding was measured with phycoerythrin (PE)-labeled secondary antibodies. Previously confirmed c-aAb positive and negative donor plasma samples and pooled normal immunoglobulin preparations were used to validate the assay. Plasma samples from 98 transfusion recipients, half of whom presented with febrile reactions, were tested by the assay. The assay detected specific and saturable immunoglobulin G (IgG) binding to each of the tested cytokines in previously confirmed c-aAb positive plasmas and in preparations of pooled normal immunoglobulin. Confirmed c-aAb negative plasmas gave no saturable binding. The detection limit of the cytokine autoantibodies was estimated to be between 1 pM and 10 pM. The recovery of confirmed cytokine autoantibodies quantities in the negative plasma samples ranged between 80% and 125%. The analytical intra- and inter-assay variations were 4% and 11%, respectively. Varying c-aAb levels were detectable in the transfusion recipients. There was no difference in c-aAb frequency between the patients with or without febrile transfusion reactions. The c-aAb level before and after the blood transfusions varied only slightly and in an irregular manner. This assay simultaneously detected up to five different c-aAbs in pooled human IgG and in plasma from individual blood donors, and it was deemed suitable for larger screenings. Based on confirmed antibody binding characteristics and the resultant reactivity in this multiplex assay, a classification of the c-aAb levels was suggested. The screening results of the recipients who received blood transfusions indicate that more studies are needed to clarify the role of antibodies, if any, in transfusion medicine and in high-dose immunoglobulin treatment. Copyright © 2015 Elsevier B.V. All rights reserved.
1981-10-01
Cryopreservation and HLA Typing of the Panel We have assembled a group of volunteer and paid blood donors, some of whom have been selected on the basis of...reagents used as controls. The cell donor panel is typed for human histocompatibility antigens. Dr. A.H. Johnson determines the HLA -A,B,C phenotypes and Dr...2 microglobulin and anti- HLA antibodies. Screening the fusions on glutaraldehyde fixed monolayers of B lymphoblastoid lines, T cell leukaemic lines
Which Donor for Uterus Transplants: Brain-Dead Donor or Living Donor? A Systematic Review.
Lavoué, Vincent; Vigneau, Cécile; Duros, Solène; Boudjema, Karim; Levêque, Jean; Piver, Pascal; Aubard, Yves; Gauthier, Tristan
2017-02-01
The aim of this systematic review was to evaluate and compare the pros and cons of using living donors or brain-dead donors in uterus transplantation programs, 2 years after the first worldwide live birth after uterus transplantation. The Medline database and the Central Cochrane Library were used to locate uterine transplantation studies carried out in human or nonhuman primates. All types of articles (case reports, original studies, meta-analyses, reviews) in English or French were considered for inclusion. Overall, 92 articles were screened and 44 were retained for review. Proof of concept for human uterine transplantation was demonstrated in 2014 with a living donor. Compared with a brain-dead donor strategy, a living donor strategy offers greater possibilities for planning surgery and also decreases cold ischemia time, potentially translating into a higher success rate. However, this approach poses ethical problems, given that the donor is exposed to surgery risks but does not derive any direct benefit. A brain-dead donor strategy is more acceptable from an ethical viewpoint, but its feasibility is currently unproven, potentially owing to a lack of compatible donors, and is associated with a longer cold ischemia time and a potentially higher rejection rate. The systematic review demonstrates that uterine transplantation is a major surgical innovation for the treatment of absolute uterine factor infertility. Living and brain-dead donor strategies are not mutually exclusive and, in view of the current scarcity of uterine grafts and the anticipated future rise in demand, both will probably be necessary.
Seroprevalence of hepatitis E virus among blood donors in Qatar (2013-2016).
Nasrallah, Gheyath K; Al Absi, Enas S; Ghandour, Rula; Ali, Nadima H; Taleb, Sara; Hedaya, Laila; Ali, Fatima; Huwaidy, Mariam; Husseini, Abdullatif
2017-07-01
Hepatitis E virus (HEV) is an RNA virus transmitted mainly through zoonotic transmission or fecal-oral route. More than 80% of Qatar's population are expatriates, including many coming from hyperendemic countries; thus, it is important to estimate the seroprevalence and to compare between different nationalities. The results can be useful in alerting blood banks to the importance of HEV screening. Samples from 5854 blood donations provided by Hamad Medical Corporation were tested in the period between June 2013 to June 2016. Samples were tested for the presence of anti-HEV immunoglobulin (Ig)G and IgM antibodies and viral RNA using real-time polymerase chain reaction (PCR). Descriptive statistics, bivariate analysis, and multivariate logistic regression were used. Anti-HEV seroprevalence was 20.7%. A total of 1198 and 38 donations tested positive for IgG and IgM antibodies, respectively. Of the IgM-positive donations four tested positive by PCR. A significant association was detected between HEV seroprevalence with age and nationality. The seroprevalence of anti-HEV was high in Qatar. Since HEV IgM and RNA were detected, this suggests the possibility of HEV transmission by transfusion. Blood banks in Qatar and the region should consider screening for HEV, especially when transfusion is intended to pregnant women or immunocompromised patients. © 2017 AABB.
Degorce, François; Card, Amy; Soh, Sharon; Trinquet, Eric; Knapik, Glenn P; Xie, Bing
2009-05-28
HTRF (Homogeneous Time Resolved Fluorescence) is the most frequently used generic assay technology to measure analytes in a homogenous format, which is the ideal platform used for drug target studies in high-throughput screening (HTS). This technology combines fluorescence resonance energy transfer technology (FRET) with time-resolved measurement (TR). In TR-FRET assays, a signal is generated through fluorescent resonance energy transfer between a donor and an acceptor molecule when in close proximity to each other. Buffer and media interference is dramatically reduced by dual-wavelength detection, and the final signal is proportional to the extent of product formation. The HTRF assay is usually sensitive and robust that can be miniaturized into the 384 and 1536-well plate formats. This assay technology has been applied to many antibody-based assays including GPCR signaling (cAMP and IP-One), kinases, cytokines and biomarkers, bioprocess (antibody and protein production), as well as the assays for protein-protein, proteinpeptide, and protein-DNA/RNA interactions.Since its introduction to the drug-screening world over ten years ago, researchers have used HTRF to expedite the study of GPCRs, kinases, new biomarkers, protein-protein interactions, and other targets of interest. HTRF has also been utilized as an alternative method for bioprocess monitoring. The first-generation HTRF technology, which uses Europium cryptate as a fluorescence donor to monitor reactions between biomolecules, was extended in 2008 through the introduction of a second-generation donor, Terbium cryptate (Tb), enhancing screening performance. Terbium cryptate possesses different photophysical properties compared to Europium, including increased quantum yield and a higher molar extinction coefficient. In addition to being compatible with the same acceptor fluorophors used with Europium, it can serve as a donor fluorophore to green-emitting fluors because it has multiple emission peaks including one at 490 nm. Moreover, all Terbium HTRF assays can be read on the same HTRF-compatible instruments as Europium HTRF assays.Overall, HTRF is a highly sensitive, robust technology for the detection of molecular interactions in vitro and is widely used for primary and secondary screening phases of drug development. This review addresses the general principles of HTRF and its current applications in drug discovery.
Code of Federal Regulations, 2013 CFR
2013-10-01
... potential donor (including point-of-care testing and blood typing) are conducted by a laboratory that is... chapter. (3) Ensure that the potential donor's blood is typed using two separate blood samples. (4) Document potential donor's record with all test results, including blood type, before organ recovery. (d...
Code of Federal Regulations, 2012 CFR
2012-10-01
... potential donor (including point-of-care testing and blood typing) are conducted by a laboratory that is... chapter. (3) Ensure that the potential donor's blood is typed using two separate blood samples. (4) Document potential donor's record with all test results, including blood type, before organ recovery. (d...
Code of Federal Regulations, 2014 CFR
2014-10-01
... potential donor (including point-of-care testing and blood typing) are conducted by a laboratory that is... chapter. (3) Ensure that the potential donor's blood is typed using two separate blood samples. (4) Document potential donor's record with all test results, including blood type, before organ recovery. (d...
21 CFR 1271.85 - What donor testing is required for different types of cells and tissues?
Code of Federal Regulations, 2010 CFR
2010-04-01
... of cells and tissues? 1271.85 Section 1271.85 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT... FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.85 What donor testing is required for different types of cells and tissues? (a) All donors...
21 CFR 1271.85 - What donor testing is required for different types of cells and tissues?
Code of Federal Regulations, 2013 CFR
2013-04-01
... of cells and tissues? 1271.85 Section 1271.85 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT... FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.85 What donor testing is required for different types of cells and tissues? (a) All donors...
21 CFR 1271.85 - What donor testing is required for different types of cells and tissues?
Code of Federal Regulations, 2014 CFR
2014-04-01
... of cells and tissues? 1271.85 Section 1271.85 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT... FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.85 What donor testing is required for different types of cells and tissues? (a) All donors...
21 CFR 1271.85 - What donor testing is required for different types of cells and tissues?
Code of Federal Regulations, 2012 CFR
2012-04-01
... of cells and tissues? 1271.85 Section 1271.85 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT... FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.85 What donor testing is required for different types of cells and tissues? (a) All donors...
Tison, Geoffrey H; Liu, Changli; Ren, Furong; Nelson, Kenrad; Shan, Hua
2007-10-01
For the past several decades, Chinese blood centers have relied on blood donations from employer-organized donors (blood donors who donate blood in groups with coworkers as prearranged by the employer and the local blood center). Recently the government has decided to phase out employer-organized donors and transition to the use of only volunteer donors (blood donors who donate individually independent of employers). Evaluating the beliefs and attitudes of employer-organized and volunteer donors is critical to maintain an adequate blood supply after this transition. The study population consisted of 431 volunteer donors and 527 employer-organized donors who completed a structured questionnaire in July 2005. Employer-organized donors tended to be older, male, and married, with higher education and higher income compared to volunteer donors. Volunteer donors were more often motivated by altruism (p < 0.001) and more likely to donate larger volumes (400 mL vs. 200 mL) of blood (volunteer 70.5% vs. employer-organized 7%; p < 0.001). Employer-organized donors were more inhibited by factors related to traditional Chinese beliefs, such as the belief that blood donation affects life energy "Qi" (volunteer 3.1% vs. employer-organized 12.7%; p < 0.001), and requested more time off from work after donating. Employer-organized donors also express a greater concern about contracting disease from donating blood. To recruit voluntary donors effectively in China and other countries with traditional cultures, efforts need to counteract traditional beliefs and perceptions of risk that discourage donation by emphasizing the benefits, safety mechanisms, physiology, and epidemiology of blood donation. In China, there is a rich opportunity to convert prior employer-organized donors into volunteer donors, and the institution of a confidential predonation screening system may help to facilitate truthful risk factor disclosure.
Arora, Disha; Garg, Ketan; Kaushik, Ankit; Sharma, Richa; Rawat, D S; Mandal, A K
2016-11-01
With increasing demand of platelet component each day, blood bank plays a pivotal role in ensuring supply of safe blood as and when required. Plateletpheresis procedure is a relatively simple, safe and important adjunct to blood bank inventory. However, recruitment of healthy blood donors is a challenge that the health industry is facing today. To determine the reasons and rates of apheresis donor deferral along with investigation of adverse reactions encountered during the procedure. Records of single donor apheresis were retrospectively analysed from 1 st January 2010 to 31 st December 2014. The study was carried out at Blood Bank, Safdarjung Hospital, New Delhi, India. The donor details that were studied included - age, sex, type of donation (voluntary/replacement/ repeat), reason for donor deferral and type of adverse reaction, if encountered during the procedure. Among the 478 donors screened for plateletpheresis procedure during a study period of 5 years, 134 (28.03%) were deferred. Temporary deferrals accounted for majority (93.28%) of the deferrals. Low platelet count (50.75%) was the main reason of donor deferral followed by low haemoglobin (20.89%). Amongst the 344 selected donors, 15 (4.36%) had some type of adverse reaction associated with the procedure. We suggest that the selection criteria for plateletpheresis donors should be revised to deal with shortage of apheresis donors. The criteria regarding minimum pre-procedure platelet count (above1.5 lac/μl) and haemoglobin (above 12.5 g/dl) need to be lowered so as to suit the Indian scenario. The lower adverse reaction rates, 14/344 (4.06%) associated with this procedure encourages safety of donors and is important in recruitment of new donors.
2015-05-22
The Food and Drug Administration (FDA) is amending the regulations applicable to blood and blood components, including Source Plasma, to make the donor eligibility and testing requirements more consistent with current practices in the blood industry, to more closely align the regulations with current FDA recommendations, and to provide flexibility to accommodate advancing technology. In order to better assure the safety of the nation's blood supply and to help protect donor health, FDA is revising the requirements for blood establishments to test donors for infectious disease, and to determine that donors are eligible to donate and that donations are suitable for transfusion or further manufacture. FDA is also requiring establishments to evaluate donors for factors that may adversely affect the safety, purity, and potency of blood and blood components or the health of a donor during the donation process. Accordingly, these regulations establish requirements for donor education, donor history, and donor testing. These regulations also implement a flexible framework to help both FDA and industry to more effectively respond to new or emerging infectious agents that may affect blood product safety.
Application of a coupled enzyme assay to characterize nicotinamide riboside kinases.
Dölle, Christian; Ziegler, Mathias
2009-02-15
The recently identified nicotinamide riboside kinases (Nrks) constitute a distinct pathway of nicotinamide adenine dinucleotide (NAD) biosynthesis. Here we present the combination of an established optical adenosine triphosphatase (ATPase) test, the pyruvate kinase/lactate dehydrogenase system, with the Nrk-catalyzed reaction to determine kinetic properties of these enzymes, in particular affinities for ATP. The assay allows variation of both nucleoside and phosphate donor substrates, thereby providing major advantages for the characterization of these enzymes. We confirm previously established kinetic parameters and identify differences in substrate selectivity between the two human Nrk isoforms. The proposed assay is inexpensive and may be applied for high-throughput screening.
DNA-Based Methods in the Immunohematology Reference Laboratory
Denomme, Gregory A
2010-01-01
Although hemagglutination serves the immunohematology reference laboratory well, when used alone, it has limited capability to resolve complex problems. This overview discusses how molecular approaches can be used in the immunohematology reference laboratory. In order to apply molecular approaches to immunohematology, knowledge of genes, DNA-based methods, and the molecular bases of blood groups are required. When applied correctly, DNA-based methods can predict blood groups to resolve ABO/Rh discrepancies, identify variant alleles, and screen donors for antigen-negative units. DNA-based testing in immunohematology is a valuable tool used to resolve blood group incompatibilities and to support patients in their transfusion needs. PMID:21257350
Barber, D; Rodríguez, R; Salcedo, G
2008-10-01
Assessment of the allergenicity of GMOs involves performing a test with a panel of sera obtained from allergic donors. However, there is no clear indication of how to characterize the above-mentioned panel. The patient selection criteria should take into account the geographical location of patients, the intensity and nature of the environmental allergens in the area and the potential cross-reactivity among allergenic molecules. Sera for serum banks, obtained from patients with demonstrated food allergy, should be subjected to a further characterization by screening with a panel of relevant allergenic molecules. A representative panel of these sera should be used in the allergenicity assessment. Finally, the "in vitro" methodologies should have the adequate specificity and sensitivity, and the integrity of the molecules tested should be guaranteed.
Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young
2008-08-01
We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.
Freitas, Daniel Roberto Coradi; Duarte, Elisabeth Carmen
2014-01-01
Objective To evaluate blood banks in the Brazilian Amazon region with regard to structure and procedures directed toward the prevention of transfusion-transmitted malaria (TTM). Methods This was a normative evaluation based on the Brazilian National Health Surveillance Agency (ANVISA) Resolution RDC No. 153/2004. Ten blood banks were included in the study and classified as ‘adequate’ (≥80 points), ‘partially adequate’ (from 50 to 80 points), or ‘inadequate’ (<50 points). The following components were evaluated: ‘donor education’ (5 points), ‘clinical screening’ (40 points), ‘laboratory screening’ (40 points) and ‘hemovigilance’ (15 points). Results The overall median score was 49.8 (minimum = 16; maximum = 78). Five blood banks were classified as ‘inadequate’ and five as ‘partially adequate’. The median clinical screening score was 26 (minimum = 16; maximum = 32). The median laboratory screening score was 20 (minimum = 0; maximum = 32). Eight blood banks performed laboratory tests for malaria; six tested all donations. Seven used thick smears, but only one performed this procedure in accordance with Ministry of Health requirements. One service had a Program of External Quality Evaluation for malaria testing. With regard to hemovigilance, two institutions reported having procedures to detect cases of transfusion-transmitted malaria. Conclusion Malaria is neglected as a blood–borne disease in the blood banks of the Brazilian Amazon region. None of the institutions were classified as ‘adequate’ in the overall classification or with regard to clinical screening and laboratory screening. Blood bank professionals, the Ministry of Health and Health Surveillance service managers need to pay more attention to this matter so that the safety procedures required by law are complied with. PMID:25453648
Factors affecting the serological testing of cadaveric donor cornea.
Raj, Anuradha; Mittal, Garima; Bahadur, Harsh
2018-01-01
The purpose of this study was to evaluate the serological profile of the eye donors and to study the influence of various factors on serological test results. A cross-sectional, observational study was conducted, and data of 509 donors were reviewed from the records of eye bank from December 2012 to June 2017. Various details of donors analyzed included the age, sex of the donor, cause of death, source of tissue, time since blood collection after death, macroscopic appearance of blood sample, and details of discarded tissues. Serological examination of blood was performed for human immunodeficiency virus (HIV), hepatitis B virus, hepatitis C virus (HCV), venereal disease research laboratory (VDRL), and serology reports reactive or nonreactive were analyzed. Among the 509 donors, 295 (58%) were male, and 420 (82.50%) belonged to age group ≥60 years. Most donors (354, 69.5%) died due to cardiac arrest. Macroscopically, sera were normal in the majority of 488 (95.9%) cases. Among 509 donors, 475 (93.3%) were nonreactive, 12 (2.4%) donors were found to be reactive to hepatitis B surface antigen (HBsAg), and 1 (0.2%) was reactive to HCV, but no donor serology was reactive to HIV or VDRL. Twenty-one (4.12%) donors' sera were not fit for serological testing. Among all donors, 475 (93.32%) donors were accepted and 34 (6.67%) were rejected or discarded on the basis of serological testing. Cause of death and macroscopic aspect of sera influenced the serological results in a highly significant manner (P = 0.00). Acceptance or rejection of the donor was significantly influenced by the serological results of the donor (P = 0.00). The seroprevalence among eye donor for HBsAg and HCV was 12 (2.4%) and 1 (0.2%), respectively. Factors such as cause of death and macroscopic aspect of sera influence the serological results. Time since blood collection or sampling will not show any impact on viral serological results if postmortem sampling will be done in < 10 hours(h) after death which can improve the safety and utility of the donor cornea.
Clinical-scale expansion of mesenchymal stromal cells: a large banking experience.
Lechanteur, Chantal; Briquet, Alexandra; Giet, Olivier; Delloye, Olivier; Baudoux, Etienne; Beguin, Yves
2016-05-20
Mesenchymal stromal cells (MSC) are largely investigated in clinical trials aiming to control inappropriate immune reactions (GVHD, Crohn's disease, solid organ transplantation). As the percentage of MSC precursors in bone marrow is very low, these must be expanded in vitro to obtain therapeutic cell doses. We describe here the constitution of an allogeneic human third-party MSC bank from screened healthy volunteer donors in compliance with quality specifications and ISCT-release criteria and report follow-up of different aspects of this activity since 2007. 68 clinical-grade large-scale MSC cultures were completed and analyzed. The whole process was described, including volunteer donor screening, bone marrow collection, mononuclear cell isolation and expansion over 4 weeks, harvesting, cryopreservation, release, administration and quality controls of the cells (including microbiology, phenotype, and potency assays). From 59 validated donors, 68 cultures were completed (mean of final yields: 886 × 10(6) cells/culture) and a total of 464 MSC aliquots have been produced and stored in liquid nitrogen (mean of 132.8 × 10(6) cells/bag). Each MSC batch underwent extensive testing to verify its conformity with EBMT and ISCT release criteria and was individually validated. As of June 1 2015, 314 bags have been released and infused to patients included in 6 different clinical protocols. All thawed MSC units satisfied to release criteria and no infusion-related toxicity was reported. In conclusion, despite low passage cultures, we have been able to create an allogeneic "off-the-shelf" MSC bank with a large number of frozen aliquots and report here an efficient clinical-grade MSC banking activity in place for more than 7 years. Our challenge now is to produce MSC in compliance with good manufacturing practices (GMP) as, in the meantime, MSC have become considered as advanced therapy medicinal products (ATMP). Another significant challenge remains the development of relevant potency assay.
Liu, Wenrui; Zhang, Jianyun; Zhou, Zichun; Zhang, Dongyang; Zhang, Yuan; Xu, Shengjie; Zhu, Xiaozhang
2018-05-16
Fused-ring electron acceptors (FREAs) have recently received intensive attention. Besides the continuing development of new FREAs, the demand for FREAs featuring good compatibility to donor materials is becoming more and more urgent, which is highly desirable for screening donor materials and achieving new breakthroughs. In this work, a new FREA is developed, ZITI, featuring an octacyclic dithienocyclopentaindenoindene central core. The core is designed by linking 2,7-dithienyl substituents and indenoindene with small methylene groups, in which the indeno[1,2-b]thiophene-2-(3-oxo-2,3-dihydro-1H-inden-1-ylidene)malononitrile part provides a large and unoccupied π-surface. Most notably, ZITI possesses an excellent compatibility with commercially available polymer donors, delivering very high power conversion efficiencies of over 13%. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wu, Yun; Xu, Kun; Ren, Chonghua; Li, Xinyi; Lv, Huijiao; Han, Furong; Wei, Zehui; Wang, Xin; Zhang, Zhiying
2017-03-01
The clustered regularly interspaced short palindromic repeat (CRISPR)/CRISPR-associated protein 9 (Cas9) system has recently emerged as a simple, yet powerful genome engineering tool, which has been widely used for genome modification in various organisms and cell types. However, screening biallelic genome-modified cells is often time-consuming and technically challenging. In this study, we incorporated two different surrogate reporter cassettes into paired donor plasmids, which were used as both the surrogate reporters and the knock-in donors. By applying our dual surrogate reporter-integrated donor system, we demonstrate high frequency of CRISPR/Cas9-mediated biallelic genome integration in both human HEK293T and porcine PK15 cells (34.09% and 18.18%, respectively). Our work provides a powerful genetic tool for assisting the selection and enrichment of cells with targeted biallelic genome modification. © 2017 Federation of European Biochemical Societies.
Mäkitie, A A; Salmi, M; Lindford, A; Tuomi, J; Lassus, P
2016-12-01
Prosthetic mask restoration of the donor face is essential in current facial transplant protocols. The aim was to develop a new three-dimensional (3D) printing (additive manufacturing; AM) process for the production of a donor face mask that fulfilled the requirements for facial restoration after facial harvest. A digital image of a single test person's face was obtained in a standardized setting and subjected to three different image processing techniques. These data were used for the 3D modeling and printing of a donor face mask. The process was also tested in a cadaver setting and ultimately used clinically in a donor patient after facial allograft harvest. and Conclusions: All the three developed and tested techniques enabled the 3D printing of a custom-made face mask in a timely manner that is almost an exact replica of the donor patient's face. This technique was successfully used in a facial allotransplantation donor patient. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Olivares-Amaya, Roberto; Hachmann, Johannes; Amador-Bedolla, Carlos; Daly, Aidan; Jinich, Adrian; Atahan-Evrenk, Sule; Boixo, Sergio; Aspuru-Guzik, Alán
2012-02-01
Organic photovoltaic devices have emerged as competitors to silicon-based solar cells, currently reaching efficiencies of over 9% and offering desirable properties for manufacturing and installation. We study conjugated donor polymers for high-efficiency bulk-heterojunction photovoltaic devices with a molecular library motivated by experimental feasibility. We use quantum mechanics and a distributed computing approach to explore this vast molecular space. We will detail the screening approach starting from the generation of the molecular library, which can be easily extended to other kinds of molecular systems. We will describe the screening method for these materials which ranges from descriptor models, ubiquitous in the drug discovery community, to eventually reaching first principles quantum chemistry methods. We will present results on the statistical analysis, based principally on machine learning, specifically partial least squares and Gaussian processes. Alongside, clustering methods and the use of the hypergeometric distribution reveal moieties important for the donor materials and allow us to quantify structure-property relationships. These efforts enable us to accelerate materials discovery in organic photovoltaics through our collaboration with experimental groups.
Yang, Haowen; Liu, Ming; Zhou, Bingcong; Deng, Yan; He, Nongyue; Jiang, Hesheng; Guo, Yafen; Lan, Ganqiu; Jiang, Qinyang; Yang, Xiurong; Li, Zhiyang
2016-06-01
Chinese Bama minipigs could be potential donors for the supply of xenografts because they are genetically stable, highly inbred, and inexpensive. However, porcine endogenous retrovirus (PERV) is commonly integrated in pig genomes and could cause a cross-species infection by xenotransplantation. For screening out the pigs with low copy numbers of PERV proviruses, we have developed a novel semiquantitative analysis approach based on magnetic nanoparticles (MNPs) and chemiluminescence (CL) for estimating relative copy numbers (RCNs) of PERV proviruses in Chinese Bama minipigs. The CL intensities of PERV proviruses and the housekeeping gene glyceraldehyde-3-phosphate dehydrogenase (GAPDH) were respectively determined with this method, and the RCNs of PERV proviruses were calculated by the equation: RCN of PERV provirus = CL intensity of PERV provirus/CL intensity of GAPDH. The results showed that PERVs were integrated in the genomes of Bama minipigs at different copy numbers, and the copy numbers of PERV-C subtype were greatly low. Two Bama minipigs with low copy numbers of PERV proviruses were detected out and could be considered as xenograft donor candidates. Although only semiquantitation can be achieved, this approach has potential for screening out safe and suitable pig donors for xenotransplantation.
Kleinman, Steven; King, Melissa R; Busch, Michael P; Murphy, Edward L; Glynn, Simone A.
2012-01-01
The Retrovirus Epidemiology Donor Study (REDS), conducted from 1989–2001, and the Retrovirus Epidemiology Donor Study-II (REDS-II), conducted from 2004–2012, were National Heart Lung and Blood Institute (NHLBI) funded multicenter programs focused on improving blood safety and availability in the United States. REDS-II also included international study sites in Brazil and China. The three major research domains of REDS/REDS-II have been infectious disease risk evaluation, blood donation availability, and blood donor characterization. Both programs have made significant contributions to transfusion medicine research methodology by the use of mathematical modeling, large-scale donor surveys, innovative methods of repository sample storage, and establishing an infrastructure that responded to potential emerging blood safety threats such as XMRV. Blood safety studies have included protocols evaluating epidemiologic and/or laboratory aspects of HIV, HTLV I/II, HCV, HBV, WNV, CMV, HHV-8, B19V, malaria, CJD, influenza, and T. cruzi infections. Other analyses have characterized: blood donor demographics, motivations to donate, factors influencing donor return, behavioral risk factors, donors’ perception of the blood donation screening process, and aspects of donor deferral. In REDS-II, two large-scale blood donor protocols examined iron deficiency in donors and the prevalence of leukocyte antibodies. This review describes the major study results from over 150 peer-reviewed articles published by these two REDS programs. In 2011, a new seven year program, the Recipient Epidemiology and Donor Evaluation Study-III (REDS-III), was launched. REDS-III expands beyond donor-based research to include studies of blood transfusion recipients in the hospital setting, and adds a third country, South Africa, to the international program. PMID:22633182
Blatyta, Paula Fraiman; Custer, Brian; Gonçalez, Thelma Terezinha; Birch, Rebecca; Lopes, Maria Esther; Ferreira, Maria Ines Lopes; Proietti, Anna Barbara Carneiro; Sabino, Ester Cerdeira; Page, Kimberly; de Almeida Neto, Cesar
2013-01-01
Background HIV risk factor screening among blood donors remains a cornerstone for the safety of blood supply and is dependent on prospective donor self-disclosure and an attentive predonation interview. Residual risk of HIV transmission through blood transfusion is higher in Brazil than in many other countries. Audio computer-assisted structured-interview (ACASI) has been shown to increase self-reporting of risk behaviors. Study design and methods This cross-sectional study was conducted between January 2009 and March 2011 at four Brazilian blood centers to identify the population of HIV-negative eligible blood donors that answered face-to-face interviews without disclosing risks, but subsequently disclosed deferrable risk factors by ACASI. Compared to the donor interview, the ACASI contained expanded content on demographics, sexual behavior and other HIV risk factors questions. Results 901 HIV-negative blood donors were interviewed. On the ACASI, 13% of donors (N=120) declared a risk factor that would have resulted in deferral that was not disclosed during the face-to-face assessment. The main risk factors identified were recent unprotected sex with an unknown or irregular partner (49 donors), sex with a person with exposure to blood/ fluids (26 donors), multiple sexual partners (19 donors), and male-male sexual behavior (10 donors). Independent factors associated with the disclosure of any risk factor for HIV were age (≥40 years vs. 18–25 years, AOR=0.45; 95% CI 0.23–0.88) and blood center (Hemope vs. Hemominas, AOR=2.51; 95% CI 1.42–4.44). Conclusion ACASI elicited increased disclosure of HIV risk factors among blood donors. ACASI may be a valuable modality of interview to be introduced in Brazilian blood banks. PMID:23521083
Development of a cross-platform biomarker signature to detect renal transplant tolerance in humans
Sagoo, Pervinder; Perucha, Esperanza; Sawitzki, Birgit; Tomiuk, Stefan; Stephens, David A.; Miqueu, Patrick; Chapman, Stephanie; Craciun, Ligia; Sergeant, Ruhena; Brouard, Sophie; Rovis, Flavia; Jimenez, Elvira; Ballow, Amany; Giral, Magali; Rebollo-Mesa, Irene; Le Moine, Alain; Braudeau, Cecile; Hilton, Rachel; Gerstmayer, Bernhard; Bourcier, Katarzyna; Sharif, Adnan; Krajewska, Magdalena; Lord, Graham M.; Roberts, Ian; Goldman, Michel; Wood, Kathryn J.; Newell, Kenneth; Seyfert-Margolis, Vicki; Warrens, Anthony N.; Janssen, Uwe; Volk, Hans-Dieter; Soulillou, Jean-Paul; Hernandez-Fuentes, Maria P.; Lechler, Robert I.
2010-01-01
Identifying transplant recipients in whom immunological tolerance is established or is developing would allow an individually tailored approach to their posttransplantation management. In this study, we aimed to develop reliable and reproducible in vitro assays capable of detecting tolerance in renal transplant recipients. Several biomarkers and bioassays were screened on a training set that included 11 operationally tolerant renal transplant recipients, recipient groups following different immunosuppressive regimes, recipients undergoing chronic rejection, and healthy controls. Highly predictive assays were repeated on an independent test set that included 24 tolerant renal transplant recipients. Tolerant patients displayed an expansion of peripheral blood B and NK lymphocytes, fewer activated CD4+ T cells, a lack of donor-specific antibodies, donor-specific hyporesponsiveness of CD4+ T cells, and a high ratio of forkhead box P3 to α-1,2-mannosidase gene expression. Microarray analysis further revealed in tolerant recipients a bias toward differential expression of B cell–related genes and their associated molecular pathways. By combining these indices of tolerance as a cross-platform biomarker signature, we were able to identify tolerant recipients in both the training set and the test set. This study provides an immunological profile of the tolerant state that, with further validation, should inform and shape drug-weaning protocols in renal transplant recipients. PMID:20501943
Zika Virus and Patient Blood Management.
Goodnough, Lawrence T; Marques, Marisa B
2017-01-01
Sporadic Zika virus infections had only occurred in Africa and Asia until an outbreak in Micronesia (Oceania) in 2007. In 2013 to 2014, several outer Pacific Islands reported local outbreaks. Soon thereafter, the virus was likely introduced in Brazil from competing athletes from French Polynesia and other countries that participated in a competition there. Transmission is thought to have occurred through mosquito bites and spread to the immunologically naive population. Being also a flavivirus, the Zika virus is transmitted by the Aedes mosquito that is endemic in South and Central America that is also the vector of West Nile virus, dengue, and chikungunya. In less than a year, physicians in Brazil reported a many-fold increase in the number of babies born with microcephaly. Despite initial skepticism regarding the causal association of the Zika virus epidemic and birth defects, extensive basic and clinical research evidence has now confirmed this relationship. In the United States, more than 4000 travel-associated infections have been reported by the middle of 2016 to the Centers for Disease Control and Prevention. Furthermore, many local mosquito-borne infections have occurred in Puerto Rico and Florida. Considering that the virus causes a viremia in which 80% of infected individuals have no symptoms, the potential for transfusion transmission from an asymptomatic blood donor is high if utilizing donor screening alone without testing. Platelet units have been shown to infect 2 patients via transfusion in Brazil. Although there was an investigational nucleic acid test available for testing donors, not all blood centers were initially required to participate. Subsequently, the US Food and Drug Administration issued a guidance in August 2016 that recommended universal nucleic acid testing for the Zika virus on blood donors.In this report, we review the potentially devastating effects of Zika virus infection during pregnancy and its implication in cases of Guillain-Barre syndrome in adults. Furthermore, we urge hospital-based clinicians and transfusion medicine specialists to implement perisurgical patient blood management strategies to avoid blood component transfusions with their potential risks of emerging pathogens, illustrated here by the Zika virus. Ultimately, this current global threat, as described by the World Health Organization, will inevitably be followed by future outbreaks of other bloodborne pathogens; the principles and practices of perioperative patient blood management will reduce the risks from not only known, but also unknown risks of blood transfusion for our patients.
Bitan, Menachem; van Walraven, Suzanna M; Worel, Nina; Ball, Lynne M; Styczynski, Jan; Torrabadella, Marta; Witt, Volker; Shaw, Bronwen E; Seber, Adriana; Yabe, Hiromasa; Greinix, Hildegard T; Peters, Christina; Gluckman, Eliane; Rocha, Vanderson; Halter, Joerg; Pulsipher, Michael A
2016-01-01
Related donors for hematopoietic cell (HC) transplantation are a growing population in recent years because of expanding indications for allogeneic transplantation. The safety and welfare of the donor are major concerns for the transplantation community, especially for related sibling donors of young recipients who are children and, thus, not able to fully consent. Because donation of HC does not improve the donor's own physical health and carries a risk of side effects, careful assessment of medical risks specific to the individual donor, as well as consideration of ethical and legal aspects associated with donation from a child, must be considered. In addition, donor centers must balance the needs of both the donor and the recipient, understanding the inherent conflict parents may have as they can be overly focused on the very sick child receiving a transplant, rather than on the relatively less significant health or emotional problems that a sibling donor may have, which could impact risk with donation. Likewise, consideration must be made regarding the nature of the relationship of the sibling donor to the recipient and also aspects of performing research on pediatric HC donors. In this article, as members of the Donor Issues Committee of the Worldwide Network for Blood and Marrow Transplantation, we review key ethical concerns associated with pediatric donation and then give recommendations for screening potential child donors with underlying health conditions. These recommendations are aimed at protecting the physical and emotional well-being of childhood donors and arise out of the Third International Conference on Health and Safety of Donors sponsored by the Worldwide Network for Blood and Marrow Transplantation. Copyright © 2016 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Kleinman, Steven; King, Melissa R; Busch, Michael P; Murphy, Edward L; Glynn, Simone A
2012-10-01
The Retrovirus Epidemiology Donor Study (REDS), conducted from 1989 to 2001, and the REDS-II, conducted from 2004 to 2012, were National Heart, Lung, and Blood Institute-funded, multicenter programs focused on improving blood safety and availability in the United States. The REDS-II also included international study sites in Brazil and China. The 3 major research domains of REDS/REDS-II have been infectious disease risk evaluation, blood donation availability, and blood donor characterization. Both programs have made significant contributions to transfusion medicine research methodology by the use of mathematical modeling, large-scale donor surveys, innovative methods of repository sample storage, and establishing an infrastructure that responded to potential emerging blood safety threats such as xenotropic murine leukemia virus-related virus. Blood safety studies have included protocols evaluating epidemiologic and/or laboratory aspects of human immunodeficiency virus, human T-lymphotropic virus 1/2, hepatitis C virus, hepatitis B virus, West Nile virus, cytomegalovirus, human herpesvirus 8, parvovirus B19, malaria, Creutzfeldt-Jakob disease, influenza, and Trypanosoma cruzi infections. Other analyses have characterized blood donor demographics, motivations to donate, factors influencing donor return, behavioral risk factors, donors' perception of the blood donation screening process, and aspects of donor deferral. In REDS-II, 2 large-scale blood donor protocols examined iron deficiency in donors and the prevalence of leukocyte antibodies. This review describes the major study results from over 150 peer-reviewed articles published by these 2 REDS programs. In 2011, a new 7-year program, the Recipient Epidemiology and Donor Evaluation Study-III, was launched. The Recipient Epidemiology and Donor Evaluation Study-III expands beyond donor-based research to include studies of blood transfusion recipients in the hospital setting and adds a third country, South Africa, to the international program. Copyright © 2012 Elsevier Inc. All rights reserved.
Population-based screening for anemia using first-time blood donors
Mast, Alan E.; Steele, Whitney R.; Johnson, Bryce; Wright, David J.; Cable, Ritchard G.; Carey, Patricia; Gottschall, Jerome L.; Kiss, Joseph E.; Simon, Toby L.; Murphy, Edward L.
2012-01-01
Background Anemia is an important public health concern. Data from population-based surveys such as the National Health and Nutrition Examination Survey (NHANES) are the gold standard, but are obtained infrequently and include only small samples from certain minority groups. Objectives We assessed whether readily available databases of blood donor hemoglobin values could be used as a surrogate for population hemoglobin values from NHANES. Design Blood donor venous and fingerstick hemoglobin values were compared to 10,254 NHANES 2005-2008 venous hemoglobin values using demographically stratified analyses and ANOVA. Fingerstick hemoglobins or hematocrits were converted to venous hemoglobin estimates using regression analysis. Results Venous hemoglobin values from 1,609 first time donors correlated extremely well with NHANES data across different age, gender and demographic groups. Cigarette smoking increased hemoglobin by 0.26 to 0.59 g/dL depending on intensity. Converted fingerstick hemoglobin from 36,793 first time donors agreed well with NHANES hemoglobin (weighted mean hemoglobin of 15.53 g/dL for donors and 15.73 g/dL for NHANES) with similar variation in mean hemoglobin by age. However, compared to NHANES, the larger donor dataset showed reduced differences in mean hemoglobin between Blacks and other races/ethnicities. Conclusions Overall, first-time donor fingerstick hemoglobins approximate U.S. population data and represent a readily available public health resource for ongoing anemia surveillance. PMID:22460662
Graham, Susanna; Jadva, Vasanti; Freeman, Tabitha; Ahuja, Kamal; Golombok, Susan
2016-12-01
The objective of this study was to examine the motivations, experiences and future expectations of identity-release egg donors in the UK following the removal of donor anonymity and the increase in financial compensation for egg donation. This exploratory, in-depth qualitative study comprised semi-structured interviews with 11 women who had attended an egg donation screening appointment at a UK clinic during a four-month period in 2014. Interviews were conducted two to six weeks after the woman had donated or had withdrawn/been rejected from the donation process. Participants' primary motivation for donating was to help infertile women have their 'own child', and the recent increase in financial compensation did not seem to play a significant role in their decision. All were happy to be identifiable and contacted by children born as a result of their donation. However, some were hesitant about providing non-identifying information about themselves for these offspring and wished for further information about the recipient(s) of their eggs and the outcome of their donation. Whilst this study was limited due to the small sample size, it is the first study of UK egg donors following the rise in donor compensation and suggests that other strategies may be more effective in increasing donor numbers.
[The Scope, Quality and Safety Requirements of Drug Abuse Testing].
Küme, Tuncay; Karakükcü, Çiğdem; Pınar, Aslı; Coşkunol, Hakan
2017-01-01
The aim of this review is to inform about the scopes and requirements of drug abuse testing. Drug abuse testing is one of the tools for determination of drug use. It must fulfill the quality and safety requirements in judgmental legal and administrative decisions. Drug abuse testing must fulfill some requirements like selection of the appropriate test matrix, appropriate screening test panel, sampling in detection window, patient consent, identification of the donor, appropriate collection site, sample collection with observation, identification and control of the sample, specimen custody chain in preanalytical phase; analysis in authorized laboratories, specimen validity tests, reliable testing METHODS, strict quality control, two-step analysis in analytical phase; storage of the split specimen, confirmation of the split specimen in the objection, result custody chain, appropriate cut-off concentration, the appropriate interpretation of the result in postanalytical phase. The workflow and analytical processes of drug abuse testing are explained in last regulation of the Department of Medical Laboratory Services, Ministry of Health in Turkey. The clinical physicians have to know and apply the quality and safety requirements in drug abuse testing according to last regulations in Turkey.
A Cluster of Fatal Tick-borne Encephalitis Virus Infection in Organ Transplant Setting.
Lipowski, Dariusz; Popiel, Marta; Perlejewski, Karol; Nakamura, Shota; Bukowska-Osko, Iwona; Rzadkiewicz, Ewa; Dzieciatkowski, Tomasz; Milecka, Anna; Wenski, Wojciech; Ciszek, Michal; Debska-Slizien, Alicja; Ignacak, Ewa; Cortes, Kamila Caraballo; Pawelczyk, Agnieszka; Horban, Andrzej; Radkowski, Marek; Laskus, Tomasz
2017-03-15
Tick-borne encephalitis virus (TBEV) infection has become a major health problem in Europe and is currently a common cause of viral brain infection in many countries. Encephalitis in transplant recipients, althrough rare, is becoming a recognized complication. Our study provides the first description of transmission of TBEV through transplantation of solid organs. Three patients who received solid organ transplants from a single donor (2 received kidney, and 1 received liver) developed encephalitis 17-49 days after transplantation and subsequently died. Blood and autopsy tissue samples were tested by next-generation sequencing (NGS) and reverse transcription polymerase chain reaction (RT-PCR). All 3 recipients were first analyzed in autopsy brain tissue samples and/or cerebrospinal fluid by NGS, which yielded 24-52 million sequences per sample and 9-988 matched TBEV sequences in each patient. The presence of TBEV was confirmed by RT-PCR in all recipients and in the donor, and direct sequencing of amplification products corroborated the presence of the same viral strain. We demonstrated transmission of TBEV by transplantation of solid organs. In such a setting, TBEV infection may be fatal, probably due to pharmacological immunosuppression. Organ donors should be screened for TBEV when coming from or visiting endemic areas. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Graham, Christopher D; Shieh, Hester F; Brazzo, Joseph A; Zurakowski, David; Fauza, Dario O
2017-06-01
Transamniotic stem cell therapy (TRASCET) with amniotic fluid-derived MSCs (afMSCs) has emerged experimentally as a practical treatment strategy for congenital anomalies. In this study, we sought to determine whether afMSCs migrate to the mother following TRASCET. Pregnant rat dams were divided into three groups. Two groups received volume-matched injections into all amniotic cavities of either a suspension of afMSCs labeled with a luciferase reporter gene or the luciferase protein alone. In a third group, a suspension of labeled cells was aliquoted onto the serosal surface of the uterus. Maternal samples from the laparotomy scar (fascia and skin separately), bone marrow, and peripheral blood were procured, along with placenta and umbilical cord. Specimens were screened for luminescence via microplate luminometry. Luminescence was detected in 60% (9/15) of the fascial scars from the group receiving intraamniotic injection of afMSCs, but in none of the other groups (P<0.001). There was a direct correlation between the presence of donor cells in the placenta and their presence in maternal fascia (Wald test=10.2; P=0.001). Amniotic mesenchymal stem cells migrate to maternal sites of injury after intraamniotic injection. Maternal homing of donor cells must be considered in the setting of transamniotic stem cell therapy. N/A (animal and laboratory study). Copyright © 2017 Elsevier Inc. All rights reserved.
Nagai, Hiroki; Sezaki, Maiko; Bertocchini, Federica; Fukuda, Kimiko; Sheng, Guojun
2014-05-01
Grafting and transplantation experiments in embryology require proper distinction between host and donor tissues. For the avian model this has traditionally been achieved by using two closely related species (e.g., chick and quail) followed by species-specific antibody staining. Here, we show that an in situ hybridization probe against the HINTW gene is a robust and reliable marker for female-derived chicken cells. At all pre-circulation stages tested, all cells in female embryos, independently confirmed by PCR analysis, were strongly positive for HINTW, whereas all male embryos were negative. This probe is broadly applicable in intra-specific chick/chick chimera studies, and as a proof of principle, we utilized this probe to detect female cells in three experimental settings: (1) to mark female donor cells in a node transplantation assay; (2) to distinguish female cells in male/female twins generated by the Cornish pasty culture; and (3) to detect female half of the embryo in artificially generated bilateral gynandromorphs. A rapid, PCR based pre-screening step increases the efficiency of obtaining desired donor/host sex combination from 25% to 100%. For most avian chimera studies, this female-specific in situ probe is a low cost alternative to the commonly used QCPN antibody and to ubiquitous-GFP chicken strains which are not widely available to the research community. © 2014 Wiley Periodicals, Inc.
A statistical model of a metallic inclusion in semiconducting media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shikin, V. B., E-mail: shikin@issp.ac.ru
The properties of an isolated multicharged atom embedded into a semiconducting medium are discussed. The analysis generalizes the results of the known Thomas–Fermi theory for a multicharged (Z ≫ 1) atom in vacuum when it is immersed into an electron–hole gas of finite temperature. The Thomas–Fermi–Debye (TFD) atom problem is directly related to the properties of donors in low-doped semiconductors and is alternative in its conclusions to the ideal scenario of dissociation of donors. In the existing ideal statistics, an individual donor under infinitely low doping is completely ionized (a charged center does not hold its neutralizing counter-ions). A Thomas–Fermi–Debyemore » atom (briefly, a TFD donor) remains a neutral formation that holds its screening “coat” even for infinitely low doping level, i.e., in the region of n{sub d}λ{sub 0}{sup 3} ≪ 1, where n{sub d} is the concentration of the doping impurity and λ{sub 0} is the Debye length with the parameters of intrinsic semiconductor. Various observed consequences in the behavior of a TFD donor are discussed that allow one to judge the reality of the implications of the TFD donor model.« less
Lesbian couples' views about and experiences of not being able to choose their sperm donor.
Ravelingien, A; Provoost, V; Wyverkens, E; Buysse, A; De Sutter, P; Pennings, G
2015-01-01
In this qualitative study, we explore how lesbian recipients view and experience the selection of their anonymous sperm donor. The study was conducted in Belgium, where fertility centres follow a legal protocol that severely restricts personal choice in donor selection. While previous studies have shown that recipients want greater control and input in the selection of their sperm donor, this was not a main concern for most women in the present study. They generally acknowledged their lack of control on the selection outcome and accepted this as part and parcel of an anonymous donation policy that provides an opportunity to have a child. They actively and passively downplayed initial concerns about the donor selection procedure and felt they did not have or need a right to further control over the donor selection. In adopting this 'subordinate' position, they felt they should trust the hospital, which they hoped would fulfil rather high screening standards. Those who did want more choice were nuanced and careful about their motivations: they focused on selecting traits that would facilitate normal child development or increase family coherence. The findings shed light on how these patients perceive their position in this third-party reproduction setting.
Wang, Xun; Jia, Yao; Xie, Yun-zheng; Li, Xiu-mei; Liu, Xiao-ying; Wu, Xiao-fei
2011-09-01
The practicable and effective methods for residual risk assessment on transfusion-transmitted disease was to establish the mathematic models. Based on the characteristics of the repeat donors which donated their blood on a regular base, a model of sero-conversion during the interval of donations was established to assess the incidence of the repeat donors. Based on the characteristics of the prevalence in the population, a model of 'prevalence increased with the age of the donor' was established to assess the incidence of those first-time donors. And based on the impact of the windows period through blood screening program, a model of residual risk associated with the incidence and the length of the windows period was established to assess the residual risk of blood transfusion. In this paper, above said 3 kinds of mathematic models were jointly applied to assess the residual risk of hepatitis C virus (HCV) which was transmitted through blood transfusion in Shanghai, based on data from the routine blood collection and screening program. All the anti-HCV unqualified blood donations were confirmed before assessment. Results showed that the residual risk of HCV transmitted through blood transfusion during Jan. 1(st), 2007 to Dec. 31(st), 2008 in Shanghai was 1:101 000. Data showed that the results of residual risk assessment with mathematic models was valuable. The residual risk of transfusion-transmitted HCV in Shanghai was at a safe level, according to the results in this paper.
Hepatitis E risks: pigs or blood-that is the question.
Tedder, Richard S; Ijaz, Samreen; Kitchen, Alan; Ushiro-Lumb, Ines; Tettmar, Kate I; Hewitt, Patricia; Andrews, Nick
2017-02-01
Infection with hepatitis E virus (HEV) Genotype 3 is recognized as a food-borne zoonosis in developed countries where it usually causes a mild self-limited acute hepatitis. It may cause a persistent infection in the immunosuppressed human that can progress to cirrhosis. To protect the patient from transfusion-acquired HEV infection, steps have been taken in the United Kingdom to provide for at-risk patients only components from donors screened for HEV viremia. This strategy does not protect from dietary exposure and calls into question estimation of relative risk between blood transfusion and diet. Using data on HEV viremia, component exposure, residual plasma volume, and resulting transmission, the dose of virus administered and subsequent transmission rates were determined and used to populate a model that can infer the relationship between blood and dietary exposure. The annual attack rate of a population, defined as seroconversion, provides an estimate of the risk of receiving a component containing HEV from a viremic donor. The lowest viral dose that resulted in infection was 2 × 10 4 IUs and 55% of components containing this dose transmitted infection. The transfusion risk of infection only exceeds the annual dietary risk when more than 13 individual donor components are transfused. For many solid organ transplant patients dietary exposure far exceeds the risk of transfusion from unscreened donors. It is only in the immunosuppressed patient requiring extensive blood component support that transfusion risk dominates. This understanding should inform policy decisions on HEV RNA screening of blood donations. © 2017 AABB.
Modeling In Situ Bioremediation of Perchlorate-Contaminated Groundwater
NASA Astrophysics Data System (ADS)
Goltz, M. N.; Secody, R. E.; Huang, J.; Hatzinger, P. B.
2007-12-01
Perchlorate-contaminated groundwater is a significant national problem. An innovative technology was recently developed which uses a pair of dual-screened treatment wells to mix an electron donor into perchlorate- contaminated groundwater in order to effect in situ bioremediation of the perchlorate by indigenous perchlorate reducing bacteria (PRB) without the need to extract the contaminated water from the subsurface. The two treatment wells work in tandem to establish a groundwater recirculation zone in the subsurface. Electron donor is added and mixed into perchlorate-contaminated groundwater flowing through each well. The donor serves to stimulate biodegradation of the perchlorate by PRB in bioactive zones that form adjacent to the injection screens of the treatment wells. In this study, a model that simulates operation of the technology was calibrated using concentration data obtained from a field-scale technology evaluation project at a perchlorate-contaminated site. The model simulates transport of perchlorate, the electron donor (citrate, for this study), and competing electron acceptors (oxygen and nitrate) in the groundwater flow field induced by operation of the treatment well pair. A genetic algorithm was used to derive a set of best-fit model parameters to describe the perchlorate reduction kinetics in this field-scale evaluation project. The calibrated parameter values were then used to predict technology performance. The model qualitatively predicted the salient characteristics of the observed data. It appears the model may be a useful tool for designing and operating this technology at other perchlorate-contaminated sites.
Puckett, A; Pratt, G
1987-01-01
A comparison of cardiolipin and a modified Treponema pallidum haemagglutination assay (TPHA) method over a four year period confirmed the superior sensitivity and specificity of TPHA. In 86,495 new donor sera 19 (0.02%) confirmed positive results were detected by TPHA, 10 of which did not react by the cardiolipin test. In 150,789 antenatal samples 49 confirmed positive results were found by TPHA, 30 of which did not react by cardiolipin. No cardiolipin positive, TPHA negative samples were confirmed as positive by the absorbed fluorescence treponemal antibody test, and overall 78% of cardiolipin reactions gave false biological positive results. Cardiolipin tests were continued only because of their speed. A further modification ("spin") of the TPHA has now been developed which is rapid, sensitive, and inexpensive, and in testing 21,807 sera, gave results equivalent to those of the previous "settle" method. Serious consideration should be given to dispensing with cardiolipin tests. PMID:3320095
Aranda, Lorena I; Smith, Linda A; Jones, Scott; Beddard, Rachel
2015-01-01
Alloimmunization to red blood cell antigens is seen in patients receiving chronic blood transfusion. Knowing the prevalence of blood group antigens of the different ethnicities of South Texas donors can provide better management of rare blood inventory for patients in this geographical area. A total of 4369 blood donors were tested and analyzed for various antigens in the following blood group systems: ABO, Rh, Kell, Duffy, Kidd, MNS, Lutheran, Dombrock, Landsteiner-Wiener, Diego, Colton, and Scianna. Donors tested to be group 0 or A were serologically tested for the Rh (C, E, c, e) antigens. Those that tested as presumably R1R1, R2R2, or Ror were then genotyped. Donors constituted three major ethnicities: black (18.3%), Hispanic (36.3%), and Caucasian (41.1%); ethnicities comprised of Asian, American Indian, multiracial, and other accounted for the remaining donors (4.3%). The most likely common Rh phenotype for each ethnicity is as follows: black -Ror (44.4%), Hispanic -R1R1 (59.0%), and Caucasian -R1R1 (38.9%). The prevalence of Kell, Duffy, and Kidd blood group system antigens in black and Caucasian donors is comparable with published reports for the entire U.S. The black South Texas donor population had an 8.8 percent increase in prevalence of the Fy(a+b-) phenotype as compared with these published reports; the Hispanic South Texas donor population had a prevalence of 36.1 percent of the Fy(a+b-) phenotype. Regarding the Diego blood group system, the Hispanic donor population in South Texas had a prevalence of 93.5 percent for the Di(a-b+) phenotype as compared with published reports for the entire U.S. (>99.9%). The Hispanic population had a prevalence of 7.9 percent of donors testing as M-N+S-s+ as compared with 20.2 percent and 15.6 percent for black and Caucasian donors, respectively. This study helped us determine the prevalence of each of the blood group antigens in the South Texas donor population to establish and maintain adequate rare inventory of each. Molecular red blood cell genotyping allows transfusion services to increase their availability of rare phenotypes for chronically transfused patients.
Ackerman, Dorothy L; Craft, Kelly M; Doster, Ryan S; Weitkamp, Jörn-Hendrik; Aronoff, David M; Gaddy, Jennifer A; Townsend, Steven D
2018-03-09
In a previous study, we reported that human milk oligosaccharides (HMOs) isolated from five donor milk samples possessed antimicrobial and antibiofilm activity against Streptococcus agalactiae, also known as Group B Streptococcus or GBS. Herein, we present a broader evaluation of the antimicrobial and antibiofilm activity by screening HMOs from 14 new donors against three strains of GBS and two of the ESKAPE pathogens of particular interest to child health, Staphylococcus aureus and Acinetobacter baumannii. Growth and biofilm assays showed that HMOs from these new donors possessed antimicrobial and antibiofilm activity against all three strains of GBS, antibiofilm activity against methicillin-resistant S. aureus strain USA300, and antimicrobial activity against A. baumannii strain ATCC 19606.
Establishment, operation and development of a donor human milk bank.
Biasini, Augusto; Stella, Marcello; Malaigia, Laura; China, Mariachiara; Azzalli, Milena; Laguardia, Maria Chiara; Rizzo, Vittoria
2013-10-01
Human milk is very valuable in premature infant nutrition. The collection, screening, processing and distribution of donor human milk are described in this report. These activities take place in the Donor Human Milk Bank (DHMB) of the Large Romagna Area (LRA) in Italy, the development of which is also described here. Over the years, the activities of this bank, which is located in Cesena Hospital, in the center of the LRA, have developed from an informal and domestic-level activity to become a multistep controlled process designed to prevent the possibility of disease transmission. This little food-supply industry, run by a multi-disciplinary team with strict rules and diverse responsibilities, complies with the Hazards Analysis and Critical Control Points (HACCP) system. © 2013.
Transfusion Medicine and Molecular Genetic Methods
Saleh, Rozieyati Mohamed; Zefarina, Zulkafli; Che Mat, Nor Fazila; Chambers, Geoffrey Keith; Edinur, Hisham Atan
2018-01-01
Transfusion procedures are always complicated by potential genetic mismatching between donor and recipient. Compatibility is determined by several major antigens, such as the ABO and Rhesus blood groups. Matching for other blood groups (Kell, Kidd, Duffy, and MNS), human platelet antigens, and human leukocyte antigens (HLAs) also contributes toward the successful transfusion outcomes, especially in multitransfused or highly immunized patients. All these antigens of tissue identity are highly polymorphic and thus present great challenges for finding suitable donors for transfusion patients. The ABO blood group and HLA markers are also the determinants of transplant compatibility, and mismatched antigens will cause graft rejection or graft-versus-host disease. Thus, a single and comprehensive registry covering all of the significant transfusion and transplantation antigens is expected to become an important tool in providing an efficient service capable of delivering safe blood and quickly locating matching organs/stem cells. This review article is intended as an accessible guide for physicians who care for transfusion-dependent patients. In particular, it serves to introduce the new molecular screening methods together with the biology of these systems, which underlies the tests. PMID:29899883
Seroprevalence of human T lymphtropic virus (HTLV) among tissue donors in Iranian tissue bank.
Arjmand, Babak; Aghayan, Seyed Hamidreza; Goodarzi, Parisa; Farzanehkhah, Mohammad; Mortazavi, Seyed Mohamadjavad; Niknam, Mohamad Hossein; Jafarian, Ali; Arjmand, Farzin; Jebelly far, Soheyla
2009-08-01
Iranian Tissue Bank prepares a wide range of human tissue homografts such as; heart valve, bone, skin, amniotic membrane and other tissues for different clinical applications. The purpose of this study was to determine the seroprevalence of HTLV in tissue donors. About 1,548 tissue donors were studied during a 5-years period by ELISA assays. HTLV(1,2)-antibodies were tested for all of donors with other tests upon American Association of Tissue Banks (AATB) standards. About 25 (1.61%) out of 1,548 tissue donors were HTLV positive that 17 donors were male and 8 were female (female/male ratio was approximately 47%). Regarding to the prevalence of HTLV among tissue donors and importance of cell and tissue safety and quality assurance, we recommend that all blood, cell and tissue banks should be involved both routine serological methods and other complementary tests such as polymerase chain reaction (PCR) for diagnosis of HTLV.
Goodwin, Jodi; Tinckam, Kathryn; denHollander, Neal; Haroon, Ayesha; Keshavjee, Shaf; Cserti-Gazdewich, Christine M
2010-09-01
It is unknown the extent to which transfusion-related acute lung injury (TRALI) contributes to primary graft dysfunction (PGD), the leading cause of death after lung transplantation. In this case of suspected transfusion-associated acute bilateral graft injury in a 61-year-old idiopathic pulmonary fibrosis patient, recipient sera from before and after transplantation/transfusion, as well as the sera of 22 of the 24 implicated blood donors, were individually screened by Luminex bead assay for the presence of human leukocyte antigen (HLA) antibodies, with recipient and lung donor HLA typing to explore for cognate relationships. A red-cell-unit donor-source anti-Cw6 antibody, cognate with the HLA type of the recipient, was identified. This is the second reported case of TRALI in the setting of lung transplantation, and the first to show an associated interaction between donor antibodies (in a low-plasma volume product) with recipient leukocytes (rather than graft antigens); therefore, it should be considered in the differential diagnosis of PGD. Copyright 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Diarra, A; Kouriba, B; Baby, M; Murphy, E; Lefrere, J-J
2009-01-01
Good data on background seroprevalence of major transfusion transmitted infections is lacking in Mali. We gathered data on the rate of positive donations of human immunodeficiency virus (HIV), hepatitis C virus (HCV), hepatitis B virus (HBV) and syphilis among blood donations in Mali for calendar year 2007. Donations with repeatedly reactive results on screening enzyme immunoassay (EIA) were considered to be seropositive. Rate of positive donations per blood unit collected was 2.6% for HIV, 3.3% for HCV, 13.9% for hepatitis B surface antigen (HBsAg) and 0.3% for syphilis. For HIV, HBsAg and syphilis, rate of positive donations was significantly (p<0.001) higher among donations from replacement donors than those from volunteer donors, while HCV rate of positive donations was similar in the two groups. Rate of positive donations was also significantly (p<0.0001) lower in blood units from regular than from first-time donors. These data reinforce WHO recommendations for increasing the number of regular, volunteer blood donors in Africa.
Regine, Vincenza; Raimondo, Mariangela; Camoni, Laura; Salfa, Maria Cristina; Gallo, Pietro; Colucci, Anna; Luzi, Anna Maria; Suligoi, Barbara
2013-01-01
Background In Italy, the circulation of human immunodeficiency virus (HIV) has expanded to include population groups that do not perceive themselves to be “at risk” of HIV infection and who do not even consider undergoing HIV testing. The aim of this study was to describe the socio-demographic and behavioural characteristics, and perceived risk of HIV infection in a sample of blood donors who reported never having been tested for HIV. Materials and methods A questionnaire was administered to a sample of donors who called the Italian National AIDS/STI Help Line and reported never having been tested for HIV. Results The study sample consisted of 164 blood donors: 29.3% had given blood in the preceding 2 years. With regards to at-risk behaviours, 39.6% of the donors interviewed were heterosexuals who had sexual contacts with multiple partners, and 5.5% were men who had sex with multiple male partners. Sexual contacts with female sex workers were reported by 11.6% of first-time donors and 25.7% of repeat donors. Of the 164 donors interviewed, 125 (76.2%) said that the main reason that they had never been tested for HIV was that they did not consider themselves at risk. Among these, 56 (44.8%) reported that they would have sexual contacts with a sex worker, 52 (41.6%) reported that they would have sexual contacts with someone having more than one sexual partner, and 36 (28.8%) reported that they would have sexual contacts without using a condom. Discussion All the donors interviewed reported that they had never been tested for HIV despite the fact that they had been certainly been tested upon blood donation. These results show that some sexual behaviours may not be perceived as behaviours at risk for acquiring HIV infection. These findings suggest that not all blood donors are knowledgeable about HIV risk behaviours and that an explicit pre-donation questionnaire and effective counselling continue to be important for the selection of candidate donors. PMID:23736932
Survival Time of Cross-Match Incompatible Red Blood Cells in Adult Horses.
Tomlinson, J E; Taberner, E; Boston, R C; Owens, S D; Nolen-Walston, R D
2015-01-01
There is a markedly reduced half-life of transfused RBCs when donor and recipient cats or humans are cross-match incompatible. Only 10-20% of horses have naturally occurring alloantibodies. Therefore, cross-match testing before blood transfusion is not always performed. Cross-match incompatibility predicts shortened RBC survival time as compared to that of compatible or autologous blood. Twenty healthy adult horses. Prospective trial. Blood type, anti-RBC antibody screen (before and 1 month after transfusion) and major and minor cross-match determined 10 donor-recipient pairs. Two pairs were cross-match compatible, the remainder incompatible. Donor blood (4 L) was collected into citrate phosphate dextrose adenine-1, labeled with NHS-biotin, and transfused into recipients. Samples were collected at 1 hour and 1, 2, 3, 5, 7, 14, 21, 28, and 35 days after transfusion, and biotinylated RBCs were detected by flow cytometry. Horses were monitored for transfusion reaction during transfusion and daily for 5 days. Cross-match incompatibility was significantly associated with decreased RBC survival time (P < .001). The half-life of transfused incompatible (cross-match >1+) allogenic equine RBCs was 4.7 (95% CI, 3.2-6.2) days versus 33.5 (24-43) days for compatible pairings. Cross-match incompatibility was associated with acute febrile transfusion reaction (P = .0083). At day 30, only 1 horse had developed novel anti-RBC antibodies. Cross-match incompatibility was predictive of febrile transfusion reaction and shortened transfused RBC survival, but did not result in production of anti-RBC antibodies at 30 days. Cross-match testing before transfusion is recommended. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Microbiological characterization of a newly established pig breed, Aachen Minipigs.
Plotzki, Elena; Heinrichs, Gerd; Kubícková, Barbara; Ulrich, Rainer G; Denner, Joachim
2016-03-01
To alleviate the shortage of human donor organs or tissues for the treatment of organ and tissue failure including diabetes, pigs are considered suitable donor animals. As organs from conventional pigs are usually too large, those from minipigs may be better suited. We recently characterized the Göttingen Minipigs, a breed well characterized concerning the presence of zoonotic microorganisms and found hepatitis E virus (HEV) and porcine cytomegalovirus (PCMV) in some animals. Here, we characterize another minipig, the Aachen Minipig (AaMP), a pig breed recently established close to the town Aachen in Germany. The animals were tested for the prevalence and expression of porcine endogenous retroviruses (PERVs) and the presence of some selected microorganisms, among them HEV, PCMV, and porcine lymphotropic herpesviruses (PLHVs) using highly sensitive and specific PCR and RT-PCR methods. In addition, we screened for antibodies against HEV and PLHV. PERV-A, PERV-B, and PERV-C sequences were found in the genome of all Aachen Minipigs. HEV RNA was found by real-time RT-PCR in most, and DNA of PCMV, PLHV-2, and PLHV-3 was found by PCR in some animals. The animals were free of eight other microorganisms tested, but some were seropositive for porcine circovirus 2 (PCV2), porcine reproductive and respiratory syndrome virus (PRRSV), and porcine epidemic diarrhea virus (PEDV). Based on medical examinations by veterinarians, the AaMP are in a good health status and seem to harbor only few microorganisms. To improve their status for use as donor pigs in xenotransplantation, the viruses detected might be eliminated by selection of negative animals, Cesarean section, and vaccination. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Prevalence of celiac disease among blood donors in São Paulo: the most populated city in Brazil.
Alencar, Marília Lage; Ortiz-Agostinho, Carmen Lucia; Nishitokukado, Lêda; Damião, Adérson O M C; Abrantes-Lemos, Clarice P; Leite, André Zonetti de Arruda; Brito, Thales de; Chamone, Dalton de Alencar Fischer; Silva, Maria Elizabeth Rossi da; Giannella-Neto, Daniel; Sipahi, Aytan Miranda
2012-09-01
Celiac disease is a permanent enteropathy caused by the ingestion of gluten, which leads to an immunemediated inflammation of the small intestine mucosa. The prevalence of celiac disease varies among different nations and ethnic backgrounds, and its diversity is determined by genetic and environmental factors. São Paulo city is one of the largest cities in the world, with a vast population and an important history of internal migratory flow from other Brazilian regions, as well as immigration from other, primarily European, countries, resulting in significant miscegenation. The aim of the present study was to estimate the prevalence of adults with undiagnosed celiac disease among blood donors of São Paulo by collecting information on the ancestry of the population studied. The prevalence of celiac disease was assessed by screening for positive IgA transglutaminase and IgA endomysium antibodies in 4,000 donors (volunteers) in the Fundação Pró-Sangue Blood Center of São Paulo, São Paulo, Brazil. The antibody-positive subjects were asked to undergo a small bowel biopsy. Of the 4,000 subjects, twenty-four had positive tests, although both antibody tests were not always concordant. For example, ten subjects were positive for IgA tissue transglutaminase only. In twenty-one positive patients, duodenal biopsies were performed, and the diagnosis of celiac disease was confirmed in fourteen patients (Marsh criteria modified by Oberhuber). In this group, 67% claimed to have European ancestry, mainly from Italy, Portugal and Spain. The prevalence of celiac disease is at least 1:286 among supposedly healthy blood bank volunteers in São Paulo, Brazil.
Application of real-time PCR and melting curve analysis in rapid Diego blood group genotyping.
Novaretti, M C Z; Ruiz, A S; Dorlhiac-Llacer, P E; Chamone, D A F
2010-01-01
The paucity of appropriate reagents for serologic typing of the Diego blood group antigens has prompted the development of a real-time PCR and melting curve analysis for Diego blood group genotyping. In this study, we phenotyped 4326 donor blood samples for Di(a) using semiautomated equipment. All 157 Di(a+) samples were then genotyped by PCR using sequence-specific primers (PCR-SSP) for DI*02 because of anti-Di(b) scarcity. Of the 4326 samples, we simultaneously tested 160 samples for Di(a) and Di(b) serology, and DI*01 and DI*02 by PCR-SSP and by real-time PCR. We used the same primers for Diego genotyping by real-time PCR and PCR-SSP. Melting curve profiles obtained using the dissociation software of the real-time PCR apparatus enabled the discrimination of Diego alleles. Of the total samples tested, 4169 blood donors, 96.4 percent (95% confidence interval [CI], 95.8-96.9%), were homozygous for DI*02 and 157, 3.6 percent (95% CI, 3.1%-4.2%), were heterozygous DI*01/02. No blood donor was found to be homozygous for DI*01 in this study. The calculated DI*01 and DI*02 allele frequencies were 0.0181 (95% CI, 0.0173-0.0189) and 0.9819 (95% CI, 0.9791-0.9847), respectively, showing a good fit for the Hardy-Weinberg equilibrium. There was full concordance among Diego phenotype results by PCR-SSP and real-time PCR. DI*01 and DI*02 allele determination with SYBR Green I and thermal cycler technology are useful methods for Diego determination. The real-time PCR with SYBR Green I melting temperature protocol can be used as a rapid screening tool for DI*01 and DI*02 blood group genotyping.
Blood component recalls in the United States.
Ramsey, G; Sherman, L A
1999-05-01
United States blood suppliers are required to recall marketed blood components later found to be in violation of Food and Drug Administration (FDA) regulations for safety, purity, and potency. Many recalled units have already been transfused. Analysis of the frequency and nature of blood component recalls would be useful for blood suppliers, transfusion services, and physicians. Each blood component recall in the weekly FDA Enforcement Report from 1990 through 1997 was examined for the number of units, recall reason, and hazard class. Units for manufacturing were excluded. In 8 years, an estimated 241,800 blood components were recalled, or approximately 1 in 700 units available to US hospitals. Eighty-eight percent of recalled units were in 22 large recalls of over 1000 units each. The most common reasons were incorrect testing for syphilis (57% of units) or viral markers (19%), reactive or previously reactive donor viral markers (6-11%), and inadequate donor-history screening (4%). Twelve units were in the FDA's highest hazard Class I, 24 percent were in Class II, and 76 percent were in Class III. Over 43,900 units had HIV-related problems, but only 3 units involved HIV transmission. Large recalls have declined since peaking in 1995, but units in small recalls increased 116 percent in 1997 over the previous 7-year average. Although high-risk recalls are rare, many blood component recalls pose medical concerns for physicians and patients. The recent decline in large recalls may be due to increased FDA oversight, stricter accreditation standards for quality improvement, and more centralized donor testing in large specialized laboratories. However, smaller recalls, which involve nearly all blood suppliers, were sharply higher in 1997.
Whole-blood donation: blood donor suitability and adverse events.
Newman, Bruce H
2004-11-01
Approximately 3% to 3.5% of the US population donates whole blood each year. Physicians might be approached by a blood donor because of a donor suitability issue, a positive postdonation test, or a donation-related complication. Approximately 83% of blood donors successfully donate; but 13% are rejected because of a donor suitability issue; 1% have a positive test, which is often nonspecific or false-positive; and 2% to 4% of the phlebotomies are not successful. The most common adverse physical events based on donor interviews are bruise (23%), sore arm (10%), fatigue (8%), and vasovagal reaction (7%), while uncommon events include nerve irritation (0.9%), syncope (0.1-0.3%), and arterial puncture (0.01%). One in 3400 donors (0.033%) report seeking outside medical care. Serious injuries occur but are very rare. More often, blood donors do well and feel satisfied with the blood donation experience.
Primary prevention of pediatric lead exposure requires new approaches to transfusion screening.
Gehrie, Eric; Keiser, Amaris; Dawling, Sheila; Travis, James; Strathmann, Frederick G; Booth, Garrett S
2013-09-01
To facilitate further assessment of transfusion-associated lead exposure by designing a procedure to test packed red blood cells (pRBCs) prepared for transfusion. The relationship between pRBCs and whole blood lead concentration was investigated in 27 samples using a modified clinical assay. Lead concentrations were measured in 100 pRBC units. Our sample preparation method demonstrated a correlation between whole blood lead and pRBC lead concentrations (R(2) = 0.82). In addition, all 100 pRBC units tested had detectable lead levels. The median pRBC lead concentration was 0.8 μg/dL, with an SD of 0.8 μg/dL and a range of 0.2-4.1 μg/dL. In addition, after only a few days of storage, approximately 25% of whole blood lead was found in the supernatant plasma. Transfusion of pRBCs is a source of lead exposure. Here we report the quantification of lead concentration in pRBCs. We found a >20-fold range of lead concentrations in the samples tested. Pretransfusion testing of pRBC units according to our proposed approach or donor screening of whole blood lead and selection of below-average units for transfusion to children would diminish an easily overlooked source of pediatric lead exposure. Copyright © 2013 Mosby, Inc. All rights reserved.
Glowacka, Ilona; Korn, Klaus; Potthoff, Sebastian A; Lehmann, Ulrich; Kreipe, Hans H; Ivens, Katrin; Barg-Hock, Hannelore; Schulz, Thomas F; Heim, Albert
2013-11-01
Human T-cell lymphotropic virus type 1 (HTLV-1) screening of blood and organ donors is not mandatory in Germany because of its low prevalence (about 7/100 000). An HTLV-1 transmission event caused by a multiple organ donor was investigated. Validity of diagnostic procedures and HTLV-1 disease association in immunosuppressed organ recipients were analyzed. Two screening immunoassays and an immunoblot (confirmatory assay) were used for detection of HLTV-1/2 antibodies. Proviral DNA was quantified in blood and biopsies of organ recipients by HTLV-1 real-time polymerase chain reaction (PCR). Proviral HTLV-1-DNA was detected in all blood samples of 3 organ recipients (1-100 copies/10(2) cells), but seroconversion was delayed for up to 2 years in screening assays and >6 years in the confirmatory assay. In 2 of 3 organ recipients, a cutaneous T-cell lymphoma was diagnosed 2 and 3 years after infection, respectively. Proviral HTLV-1 DNA concentration was almost 100 copies/10(2) cells in cutaneous lymphoma biopsies whereas in biopsies of other tissues ≤3.0 copies/10(2) cells were found. The third organ recipient did not suffer from lymphoma, but detailed clinical data on this patient were not available to us. Biopsy results support an etiological role for HTLV-1 in these cases of primary cutaneous T-cell lymphoma after solid organ transplant. HTLV-1-associated lymphoma can arise quickly in immunocompromised transplant recipients. The diagnosis of potentially HTLV-1-associated disease in organ recipients may require PCR because of delayed seroconversion.
Hepatitis A: an epidemiological survey in blood donors, France 2015 to 2017.
Gallian, Pierre; Barlet, Valérie; Mouna, Lina; Gross, Sylvie; Lecam, Sophie; Ricard, Céline; Wind, Françoise; Pouchol, Elodie; Fabra, Cécile; Flan, Benoit; Visse, Catherine; Djoudi, Rachid; Couturier, Elisabeth; de Valk, Henriette; Tiberghien, Pierre; Roque-Afonso, Anne-Marie
2018-05-01
Since mid-2016, hepatitis A virus (HAV) outbreaks, involving predominantly men who have sex with men (MSM), have affected countries in Europe and overseas. In France, HAV screening of blood donations in 2017 revealed a HAV-RNA prevalence ca fivefold higher than during 2015-16 (4.42/106 vs 0.86/106; p = 0.0005). In 2017, despite a higher male-to-female ratio (5.5 vs 0.7) and the identification of MSM-associated outbreak strains, only one of 11 infected male donors self-reported being a MSM.
González, Rocio; Echevarria, José Manuel; Avellón, Ana; Barea, Luisa; Castro, Emma
2006-07-01
Mathematical models predict that, in Spain, a significant number of blood units will be obtained during the window period of the hepatitis B virus (HBV) infection. Routine nucleic acid testing (NAT) on individual blood units may provide experimental data to evaluate such a theoretical risk. Between February and July 2005, a total of 34,631 individual units were screened for HBV DNA by a multiplex transcription-mediated amplification (TMA) test. Units that repeatedly reacted in the test, but did not react for HBV surface antigen (HBsAg), were submitted to additional testing by both molecular and conventional assays, and the donors were recalled for follow-up studies and the collection of clinical and epidemiologic data. Confirmatory testing and follow-up studies identified 2 blood units donated during the HBV infection window period (1/17,316 units studied). Sequencing of amplification products obtained by nested polymerase chain reaction (n-PCR) revealed two HBV strains from genotypes D/ayw3 and F/adw4q-, but did not identify HBsAg mutants. The HBV DNA concentration in the index donations was estimated to be below the n-PCR detection level (180 IU/mL), in both cases. One donor developed acute hepatitis 2 months after donating blood, but the other remained asymptomatic and displayed normal alanine aminotransferase levels at follow-up. The HBV infection window period is a real issue in the setting of Spanish blood transfusions. NAT of individual units by TMA would make a significant contribution to improving the safety of the blood supply in Spain. Additional studies involving a larger number of units and longer periods of time are required, however, to ascertain the true incidence of the problem in this country.
Crawshaw, Marilyn
2017-07-11
Increasing numbers of donor-conceived individuals (and/or parents) are seeking individuals genetically related through donor conception. One route is through 'direct-to-consumer' (DTC) DNA testing, prompting calls for fertility services to alert donors and prospective parents to the increasing unsustainability of anonymity and secrecy. The complexity of interpreting DNA results in this context has also been discussed, including their lack of absolute certainty, as has the need for professional and peer support. This commentary highlights a different 'threat', from individuals learning of their donor-conception origins through the use of such tests by themselves or relatives for such purposes as genealogy or health checks. It illustrates the personal complexities faced by three older women and their families on learning not only of their genetic relationship to each other but also to 15 more donor-related siblings. DTC DNA services are a growing feature of modern life. This commentary raises ethical questions about their responsibilities towards those inadvertently learning of donor conception origins and the responsibilities of fertility services to inform prospective parents and donors of this new phenomenon. Considerations of how and when parents should tell their children of their donor-conception origins here instead become how and when children should inform their parents.
Blood donor notification and counseling: Our experience from a tertiary care hospital in India
Kotwal, Urvershi; Doda, Veena; Arora, Satyam; Bhardwaj, Swati
2015-01-01
Aims: To evaluate the response rate of transfusion-transmissible infection (TTI)-reactive donors after notification of their abnormal test results for the year 2012. Materials and Methods: This study is an observational descriptive study performed in our department over a period of 1 year. We evaluated the response rate of TTI-reactive donors after notification of their abnormal test results over 1 year as per the existing strategy (three telephonic and two postal communications). Results: During the study period, among the annual donation of 15,322 units, 464 blood donors were found to be seroreactive. Of these 464 seroreactive cases, 47 were HIV positive, 284 were reactive for Hepatitis B surface antigen (HBsAg), 49 were Hepatitis C (HCV) positive and 84 were VDRL reactive. The TTI-reactive donors (464) for various markers were contacted: 229 (49.4%) telephonically and the remaining 235 (50.6%) not contacted on phone were informed by post. Of the 229 contacted donors, the response rate was 98.2% as only 225 donors reported (221 on the first, three on second and one on the third call) for one to one counseling. The remaining four non-responders were - one HIV and three HBsAg reactive. The remaining 235 (50.6%) reactive donors did not respond to any communication. Conclusion: Donor notification and post-donation counseling are an essential aspect of the blood bank that entails provision of information on serological status, assess the impact of test results on the donor and finally referral for medical care. As in our data only 49.4% of the blood donors could be contacted successfully, incomplete demographic details was the major limiting factor in communicating with rest. Of the 229 contacted donors, the response rate was 98.2%. A large majority (94.75%) of the notified donors in our study contacted their health care provider when given clear instructions to do so. These results are encouraging because they indicate that a major element of the notification message is acted upon when it is worded clearly. The very high response rate of the contacted donors ensured their concern for knowing their test result status. PMID:25722567
Krickhahn, Mareike; Bühler, Christoph; Meyer, Thomas; Thiede, Arnulf; Ulrichs, Karin
2002-01-01
Clinical islet allotransplantation has become an increasingly efficient "routine" therapy in recent years. Shortage of human donor organs leads to porcine pancreatic islets as a potential source for islet xenotransplantation. Yet it is still very difficult to isolate sufficient numbers of intact porcine islets, particularly from young market pigs. In the following study islets were successfully isolated from retired breeders [4806 +/- 720 islet equivalents per gram organ (IEQ/g); n = 25; 2-3 years old; RB] and also from young hybrid pigs [2868 +/- 260 IEQ/g; n = 65; 4-6 months old; HY] using LiberasePI and a modified version of Ricordi's digestion-filtration technique. As expected, isolations from RB showed significantly better results (p < 0.002). A retrospective histological analysis of almost all donor pancreases showed that the majority of organs from RB (80%) contained mainly large islets (diameter > 200 microm), in contrast to only 35% of all pancreases from HY. Remarkably, the islet size in situ, regardless whether detected in RB or HY, strongly determined the isolation result. A donor organ with predominantly large islets resulted in significantly higher numbers of IEQs compared with a donor organ with predominantly small islets [RB(Large Islets): 5680 +/- 3,318 IEQ/g (n= 20); RB(Small Islets): 1353 +/- 427 IEQ/g (n = 5); p < 0.02]. In addition, isolation results were strongly influenced by the quality of the LiberasePI batch, and therefore single batch testing is invariably required. Purification was performed using Ficoll or OptiPrep density gradient centrifugation manually or in the COBE cell processor. Although islet purity was highest when OptiPrep was used, final islet yields did not differ between the different purification methods. Our study demonstrates that islet size in situ is an extremely critical parameter for highly successful islet isolation; consequently, we are now performing a morphological screening of each donor organ prior to the isolation process. Under these conditions highly successful isolations can reliably be performed even from young market pigs.
Applicability of the ParaDNA(®) Screening System to Seminal Samples.
Tribble, Nicholas D; Miller, Jamie A D; Dawnay, Nick; Duxbury, Nicola J
2015-05-01
Seminal fluid represents a common biological material recovered from sexual assault crime scenes. Such samples can be prescreened using different techniques to determine cell type and relative amount before submitting for full STR profiling. The ParaDNA(®) Screening System is a novel forensic test which identifies the presence of DNA through amplification and detection of two common STR loci (D16S539 and TH01) and the Amelogenin marker. The detection of the Y allele in samples could provide a useful tool in the triage and submission of sexual assault samples by enforcement authorities. Male template material was detected on a range of common sexual assault evidence items including cotton pillow cases, condoms, swab heads and glass surfaces and shows a detection limit of 1 in 1000 dilution of neat semen. These data indicate this technology has the potential to be a useful tool for the detection of male donor DNA in sexual assault casework. © 2015 American Academy of Forensic Sciences.
ABO, Rhesus, and Kell Antigens, Alleles, and Haplotypes in West Bengal, India
Basu, Debapriya; Datta, Suvro Sankha; Montemayor, Celina; Bhattacharya, Prasun; Mukherjee, Krishnendu; Flegel, Willy A.
2018-01-01
Background Few studies have documented the blood group antigens in the population of eastern India. Frequencies of some common alleles and haplotypes were unknown. We describe phenotype, allele, and haplotype frequencies in the state of West Bengal, India. Methods We tested 1,528 blood donors at the Medical College Hospital, Kolkata. The common antigens of the ABO, Rhesus, and Kell blood group systems were determined by standard serologic methods in tubes. Allele and haplotype frequencies were calculated with an iterative method that yielded maximum-likelihood estimates under the assumption of a Hardy-Weinberg equilibrium. Results The prevalence of ABO antigens were B (34%), O (32%), A (25%), and AB (9%) with ABO allele frequencies for O = 0.567, A = 0.189, and B = 0.244. The D antigen (RH1) was observed in 96.6% of the blood donors with RH haplotype frequencies, such as for CDe = 0.688809, cde = 0.16983 and CdE = 0.000654. The K antigen (K1) was observed in 12 donors (0.79%) with KEL allele frequencies for K = 0.004 and k = 0.996. Conclusions: For the Bengali population living in the south of West Bengal, we established the frequencies of the major clinically relevant antigens in the ABO, Rhesus, and Kell blood group systems and derived estimates for the underlying ABO and KEL alleles and RH haplotypes. Such blood donor screening will improve the availability of compatible red cell units for transfusion. Our approach using widely available routine methods can readily be applied in other regions, where the sufficient supply of blood typed for the Rh and K antigens is lacking. PMID:29593462
Böhmig, G A; Regele, H; Säemann, M D; Exner, M; Druml, W; Kovarik, J; Hörl, W H; Zlabinger, G J; Watschinger, B
2000-04-01
Excellent graft outcome has been reported for spousal-donor kidney transplantation. In husband-to-wife transplantation, however, a tendency toward inferior graft survival has been described for recipients who were previously pregnant. In our series of spousal-kidney transplantations (nine transplantations; three female recipients), actual graft survival is 100% (median observation time, 339 days). Five patients experienced early allograft rejection. In four transplant recipients, rejection was easily reversible by conventional antirejection therapy. In a multiparous recipient, however, mild interstitial allograft rejection associated with early graft dysfunction was resistant to anticellular treatment (antilymphocyte antibody, tacrolimus rescue therapy). The particular finding of polymorphonuclear neutrophils in peritubular capillaries and the finding of diffuse capillary deposits of the complement split product, C4d, in a posttransplantation biopsy specimen suggested a role of antibody-mediated graft injury. Retrospective flow cytometry cross-matching showed the presence of preformed immunoglobulin G (IgG) antibodies to HLA class I antigens that were not detectable by pretransplantation lymphocytotoxic cross-match testing or screening for panel reactive antibodies. After transplantation, however, complement-fixing antibodies, also presumably triggered by reexposure to spousal-donor HLA antigens, could be detected in the patient's serum. These findings suggested antibody-mediated allograft rejection and led to the initiation of immunoadsorption therapy (14 sessions) with staphylococcal protein A. Selective removal of recipient IgG resulted in complete reversal of graft dysfunction. Our findings suggest that in husband-to-wife transplantation, donor-specific antibodies, presumably triggered by previous pregnancies, might occasionally induce sustained allograft dysfunction. Thus, in this particular setting, a detailed immunologic and histopathologic work-up regarding antibody-mediated allograft dysfunction is warranted because immunoadsorption may be a highly effective treatment modality.
Genotypic distribution of hepatitis C virus in voluntary blood donors of northern Thailand.
Jutavijittum, Prapan; Jiviriyawat, Yupa; Yousukh, Amnat; Pantip, Chansom; Maneekarn, Niwat; Toriyama, Kan
2009-05-01
The purpose of this study was to determine the prevalence and distribution of HCV genotypes among voluntary blood donors in northern Thailand. From 1998 to 2000, 167 serum samples which tested positive for anti-HCV antibodies in the screening of voluntary blood donors from 5 provinces in northern Thailand were selected for genotyping. Viral RNA was extracted from the sera. The core-E1 region of the HCV-RNA genome was amplified using a OneStep RT-PCR kit. The core-E1 amplicon was sequenced and the HCV genotype was assigned by comparing with the reference sequences available in the GenBank database. Of 167 anti-HCV positive serum samples, 126 (75.4%) contained HCV RNA as detected by PCR. HCV genotype 3 was the most predominant genotype (39.6%), of which 33.3% belonged to genotype 3a and 6.3% to 3b. Genotype 6 was detected in 31%, and genotype 1 was detected in 27.8%. Of the genotype 1 isolates, 14.3% were la, 12.7% were 1b, and 0.8% were 1c. Two HCV isolates detected in the present study were untypeable. About 75% of anti-HCV positive blood donors had chronic HCV infection. In northern Thailand, genotype 3a was the most predominant genotype, while genotype 6, 1a and 1b were also commonly found. The genotypic distribution of HCV isolates from various regions of Thailand were more or less similar. Nevertheless, in this study, the prevalence of HCV genotype 6 (31%) was higher than previously reported by others (8-18%). Phylogenetic analysis of the HCV isolates detected in the present study was also performed.
Development of an in vitro alternative assay method for vaginal irritation.
Ayehunie, Seyoum; Cannon, Chris; Larosa, Karen; Pudney, Jeffrey; Anderson, Deborah J; Klausner, Mitchell
2011-01-11
The vaginal mucosa is commonly exposed to chemicals and therapeutic agents that may result in irritation and/or inflammation. In addition to acute effects, vaginal irritation and inflammation can make women more susceptible to infections such as HIV-1 and herpes simplex virus 2 (HSV-2). Hence, the vaginal irritation potential of feminine care formulations and vaginally administered therapeutic agents is a significant public health concern. Traditionally, testing of such materials has been performed using the rabbit vaginal irritation (RVI) assay. In the current study, we investigated whether the organotypic, highly differentiated EpiVaginal™ tissue could be used as a non-animal alternative to the RVI test. The EpiVaginal tissue was exposed to a single application of ingredients commonly found in feminine hygiene products and the effects on tissue viability (MTT assay), barrier disruption (measured by transepithelial electrical resistance, TEER and sodium fluorescein (NaFl) leakage), and inflammatory cytokine release (interleukin (IL)-1α, IL-1β, IL-6, and IL-8) patterns were examined. When compared to untreated controls, two irritating ingredients, nonoxynol 9 and benzalkonium chloride, reduced tissue viability to <40% and TEER to <60% while increasing NaFl leakage by 11-24% and IL-1α and IL-1β release by >100%. Four other non-irritating materials had minimal effects on these parameters. Assay reproducibility was confirmed by testing the chemicals using three different tissue production lots and by using tissues reconstructed from cells obtained from three different donors. Coefficients of variation between tissue lots reconstructed with cells obtained from the same donor or lots reconstructed with cells obtained from different donors were less than 10% and 12%, respectively. In conclusion, decreases in tissue viability and barrier function and increases in IL-1α and IL-1β release appear to be useful endpoints for preclinical screening of topically applied chemicals and formulations for their vaginal irritation potential. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Bueno, Ednéia C.; Snege, Miriam; Vaz, Adelaide J.; Leser, Paulo G.
2001-01-01
Neurocysticercosis (NC), caused by the presence of Taenia solium metacestodes in tissues, is a severe parasitic infection of the central nervous system with universal distribution. To determine the efficiency of enzyme-linked immunosorbent assay (ELISA) and immunoblot with antigens of T. crassiceps vesicular fluid (Tcra) compared to standard techniques (indirect immunofluorescence test [IFT] and complement fixation test [CFT]) using T. solium cysticerci (Tso) for the serodiagnosis of NC, we studied serum samples from 24 patients with NC, 30 supposedly healthy individuals, 76 blood bank donors, 45 individuals with other non-NC parasitoses, and 97 samples from individuals screened for cysticercosis serology (SC). The sensitivity observed was 100% for ELISA-Tso and ELISA-Tcra, 91.7% for the IFT, and 87.5% for the CFT. The specificity was 90% for ELISA-Tso, 96.7% for ELISA-Tcra, 50% for IFT, and 63.3% for CFT. The efficiency was highest for ELISA-Tcra, followed by ELISA-Tso, IFT, and CFT. Of the 23 samples from SC group, which were reactive to ELISA-Tso and/or ELISA-Tcra, only 3 were positive to immunblot-Tcra (specific peptides of 14- and 18-kDa) and to glycoprotein peptides purified from Tcra antigen (gp-Tcra), showing the low predictive value of ELISA for screening. None of the samples from the remaining groups showed specific reactivity in immunoblot-Tcra. These results demonstrate that ELISA-Tcra can be used as a screening method for the serodiagnosis of NC and support the need for specific tests for confirmation of the results. The immunoblot can be used as a confirmatory test both with Tcra and gp-Tcra, with the latter having an advantage in terms of visualization of the results. PMID:11687454
Blood donors' attitudes towards incentives: influence on motivation to donate.
Kasraian, Leila; Maghsudlu, Mahtab
2012-04-01
Understanding the factors that motivate donors to donate will facilitate improvements in recruitment programmes. Donation incentives are often used to improve the effect of recruitment programmes. This cross-sectional study was designed to understand donors' attitudes toward incentives. Participants (n=421) were recruited among volunteer donors at the Shiraz Blood Transfusion Centre when they registered for blood donation. They completed a questionnaire with items regarding demographic characteristics, donation status (first-time donor or regular donor), and their motivation for donating, their attitude towards incentives, and the best type of incentives. Multiple logistic regression and chi-squared tests were used to analyse the data with Statistical Package for the Social Sciences (SPSS) software. The majority of donors (85.6%) donated blood for altruistic reasons. One quarter of the donors (25.3%) believed that incentives should be offered to encourage them to donate. Most donors (84.5%) believed that the most effective incentive was offering specific blood tests. Donors who had donated for non-altruistic reasons were more interested in receiving incentives. The desire to receive incentives was more widespread among younger, married, first-time donors, donors with a lower educational level and donors with a history of more than five donations. The desire to receive incentives decreased as age increased. Most of the donors (74.7%) had no desire to receive incentives, and this was even more apparent among donors who donated for altruistic reasons. Non-monetary incentives may be effective in attracting younger, married, first-time donors, donors with a lower educational level and donors with a history of more than five donations.
Donor transmitted and de novo cancer after liver transplantation
Desai, Rajeev; Neuberger, James
2014-01-01
Cancers in solid organ recipients may be classified as donor transmitted, donor derived, de novo or recurrent. The risk of donor-transmitted cancer is very low and can be reduced by careful screening of the donor but cannot be abolished and, in the United Kingdom series is less than 0.03%. For donors with a known history of cancer, the risks will depend on the nature of the cancer, the interventions given and the interval between diagnosis and organ donation. The risks of cancer transmission must be balanced against the risks of death awaiting a new graft and strict adherence to current guidelines may result increased patient death. Organs from selected patients, even with high-grade central nervous system (CNS) malignancy and after a shunt, can, in some circumstances, be considered. Of potential donors with non-CNS cancers, whether organs may be safely used again depends on the nature of the cancer, the treatment and interval. Data are scarce about the most appropriate treatment when donor transmitted cancer is diagnosed: sometimes substitution of agents and reduction of the immunosuppressive load may be adequate and the impact of graft removal should be considered but not always indicated. Liver allograft recipients are at increased risk of some de novo cancers, especially those grafted for alcohol-related liver disease and hepatitis C virus infection. The risk of lymphoproliferative disease and cancers of the skin, upper airway and bowel are increased but not breast. Recipients should be advised to avoid risk behavior and monitored appropriately. PMID:24876738
Liver Transplantation Outcomes Using Grafts From Donors Older Than the Age of 80 Years.
Rabelo, A V; Alvarez, M J; Méndez, C S M; Villegas, M T; MGraneroa, K; Becerra, A; Dominguez, M; Raya, A M; Exposito, M; Suárez, Y F
2015-11-01
We performed a retrospective cohort study between 2002 and 2014 to compare liver transplantation outcomes between recipients of grafts from donors older than and younger than the age of 80 years. Numerical variables were compared with the Student t test when their distribution was normal and the Mann-Whitney test when it was not, whereas categorical variables were compared with Pearson chi-squared test or Fisher test, as appropriate; P < .05 was considered significant. The study included 312 patients with organs from donors younger than 80 years of age and 17 with organs from older donors. The 2 recipient groups did not significantly differ in weight, height, gender, body mass index (BMI), CHILD or MELD score, intensive care unit (ICU) or hospital stay, need for intraoperative hemoderivatives, postreperfusion syndrome, biliary or vascular complications, ischemic cholangiopathy, number of repeat surgeries, graft rejection, retransplantation, or survival at 6 months. Although earlier studies considered livers from elderly donors to be suboptimal, our results support the proposition that octogenarian donors can be an excellent source of liver grafts. Copyright © 2015 Elsevier Inc. All rights reserved.
[Histocompatibility tests in a transplantation program].
de-Leo-Cervantes, Claudia
2005-01-01
The importance of the role of the histocompatibility laboratory in solid organ transplantation is to perform HLA typing and determine the degree of HLA matching between recipient/donor. It is a useful tool to increase graft survival and decrease chronic rejection. HLA matching has a positive effect on kidney transplants and it has variable impact on other organ transplants. The crossmatch procedure is the most important test in a solid organ transplantation to evaluate the presence of recipient antibodies to antigens expressed on donor white cells. This test decreases the risk of hyperacute humoral rejection or early graft loss. Positive crossmatch is a contraindication for transplantation because it represents the existence of IgG recipient antibodies that will reath againts donor antigens. Antibody evaluation is important in donor-recipient selection and the responsability of the histocompatibility laboratory is to identify clinically relevant anti-donor HLA antibodies. This detection is useful to determine the degree of humoral alloimmunization, expressed as a percent panel reactive antibody (%PRA). This test also provides information about the antibody specificity and can be used for evaluate a patient's immune status providing a significant correlation in selecting donors.
McGregor, D K; Keever-Taylor, C A; Bredeson, C; Schur, B; Vesole, D H; Logan, B; Chang, C-C
2005-06-01
We performed real-time quantitative polymerase chain reaction (RQ-PCR) in peripheral blood (PB) and/or bone marrow (BM) samples collected pre- and post transplant from 23 recipient-donor pairs receiving allogeneic stem cell transplantation (allo-SCT) for follicular lymphoma (FL). Of 23 donors, 11 had a PB and/or BM sample positive for t(14;18) (BCL2/IGH fusion) at low levels (
Virology, serology, and demography of hepatitis E viremic blood donors in South East England.
Tedder, Richard S; Tettmar, Kate I; Brailsford, Su R; Said, Bengu; Ushiro-Lumb, Ines; Kitchen, Alan; Morgan, Dilys; Lattimore, Sam; Tossell, Joanne; Ijaz, Samreen; Hewitt, Patricia E
2016-06-01
Hepatitis E virus (HEV) Genotype 3 (G3) in England comprises two principal phylogenetic groups (Group 1 and Group 2) and can be transmitted by transfusion. Unselected screening identified 79 viremic donors; 76 participated in a follow-up study. Viral RNA dynamics, phylogenetics, and seroconversion were characterized in the donors. Detailed demographic, travel, clinical, and lifestyle questionnaires were undertaken. The majority of viremic individuals (57/79) were seronegative at time of donation but all seroconverted. Viremia was short-lived, with a median of 6.5 weeks to confirmed viral clearance. All infections were acquired in the United Kingdom and were G3, with Group 2 viruses predominating (43/54; 80%). Infection was associated with some clinical symptoms both at and after donation (8/77; 10%). Viral loads and symptoms were more pronounced in Group 1 infections. There was no serologic evidence of reinfection. Donors were more commonly male (p = 0.002); both male and female donors were older than comparator donors. Animal contact was unlikely to be the source of infection. Consumption of chicken and pig meat was common to all infected donors; processed pig meat was most commonly purchased from one particular retail chain. Viremic donors represent primary infection in older members of the community and reflect a widespread zoonotic in the United Kingdom. The two phylogenetic groups of HEV G3 display different pathogenicity and the more common Group 2 appears less adapted to humans. There are no objective demographic criteria that can identify donors at enhanced HEV risk. © 2016 AABB.
Transmission of West Nile virus from an organ donor to four transplant recipients.
Iwamoto, Martha; Jernigan, Daniel B; Guasch, Antonio; Trepka, Mary Jo; Blackmore, Carina G; Hellinger, Walter C; Pham, Si M; Zaki, Sherif; Lanciotti, Robert S; Lance-Parker, Susan E; DiazGranados, Carlos A; Winquist, Andrea G; Perlino, Carl A; Wiersma, Steven; Hillyer, Krista L; Goodman, Jesse L; Marfin, Anthony A; Chamberland, Mary E; Petersen, Lyle R
2003-05-29
In August 2002, fever and mental-status changes developed in recipients of organs from a common donor. Transmission of West Nile virus through organ transplantation was suspected. We reviewed medical records, conducted interviews, and collected blood and tissue samples for testing with a variety of assays. Persons who donated blood to the organ donor and associated blood components were identified and tested for West Nile virus. We identified West Nile virus infection in the organ donor and in all four organ recipients. Encephalitis developed in three of the organ recipients, and febrile illness developed in one. Three recipients became seropositive for West Nile virus IgM antibody; the fourth recipient had brain tissue that was positive for West Nile virus by isolation and nucleic acid and antigen assays. Serum specimens obtained from the organ donor before and immediately after blood transfusions showed no evidence of West Nile virus; however, serum and plasma samples obtained at the time of organ recovery were positive on viral nucleic acid testing and viral culture. The organ donor had received blood transfusions from 63 donors. A review of blood donors and follow-up testing identified one donor who had viremia at the time of donation and who became seropositive for West Nile virus IgM antibodies during the next two months. Our investigation of this cluster documents the transmission of West Nile virus by organ transplantation. Organ recipients receiving immunosuppressive drugs may be at high risk for severe disease after West Nile virus infection. Blood transfusion was the probable source of the West Nile virus viremia in the organ donor. Copyright 2003 Massachusetts Medical Society
Mapping the Relationship between Glycosyl Acceptor Reactivity and Glycosylation Stereoselectivity.
van der Vorm, Stefan; van Hengst, Jacob M A; Bakker, Marloes; Overkleeft, Herman S; van der Marel, Gijsbert A; Codée, Jeroen D C
2018-03-30
The reactivity of both coupling partners-the glycosyl donor and acceptor-is decisive for the outcome of a glycosylation reaction, in terms of both yield and stereoselectivity. Where the reactivity of glycosyl donors is well understood and can be controlled through manipulation of the functional/protecting-group pattern, the reactivity of glycosyl acceptor alcohols is poorly understood. We here present an operationally simple system to gauge glycosyl acceptor reactivity, which employs two conformationally locked donors with stereoselectivity that critically depends on the reactivity of the nucleophile. A wide array of acceptors was screened and their structure-reactivity/stereoselectivity relationships established. By systematically varying the protecting groups, the reactivity of glycosyl acceptors can be adjusted to attain stereoselective cis-glucosylations. © 2018 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.
Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique
2017-01-01
In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.
Lafranca, Jeffrey A; Spoon, Emerentia Q W; van de Wetering, Jacqueline; IJzermans, Jan N M; Dor, Frank J M F
2017-01-01
The transplant community increasingly accepts extended criteria live kidney donors, however, great (geographical) differences are present in policies regarding the acceptance of these donors, and guidelines do not offer clarity. The aim of this survey was to reveal these differences and to get an insight in both centre policies as well as personal beliefs of transplant professionals. An online survey was sent to 1128 ESOT-members. Questions were included about several extended donor criteria; overweight/obesity, older age, vascular multiplicity, minors as donors and comorbidities; hypertension, impaired fasting glucose, kidney stones, malignancies and renal cysts. Comparisons were made between transplant centres of three regions in Europe and between Europe and other countries worldwide. 331 questionnaires were completed by professionals from 55 countries. Significant differences exist between regions in Europe in acceptance of donors with several extended criteria. Median refusal rate for potential live donors is 15%. Furthermore, differences are seen regarding pre-operative work-up, both in specialists who perform screening as in preoperative imaging. Remarkably, 23.4% of transplant professionals sometimes deviate from their centre policy, resulting in more or less comparable personal beliefs regarding extended criteria. Variety is seen, proving the need for a standardized approach in selection, preferably evidence based.
Spoon, Emerentia Q. W.; van de Wetering, Jacqueline; IJzermans, Jan N. M.; Dor, Frank J. M. F.
2017-01-01
Background The transplant community increasingly accepts extended criteria live kidney donors, however, great (geographical) differences are present in policies regarding the acceptance of these donors, and guidelines do not offer clarity. The aim of this survey was to reveal these differences and to get an insight in both centre policies as well as personal beliefs of transplant professionals. Methods An online survey was sent to 1128 ESOT-members. Questions were included about several extended donor criteria; overweight/obesity, older age, vascular multiplicity, minors as donors and comorbidities; hypertension, impaired fasting glucose, kidney stones, malignancies and renal cysts. Comparisons were made between transplant centres of three regions in Europe and between Europe and other countries worldwide. Results 331 questionnaires were completed by professionals from 55 countries. Significant differences exist between regions in Europe in acceptance of donors with several extended criteria. Median refusal rate for potential live donors is 15%. Furthermore, differences are seen regarding pre-operative work-up, both in specialists who perform screening as in preoperative imaging. Conclusions Remarkably, 23.4% of transplant professionals sometimes deviate from their centre policy, resulting in more or less comparable personal beliefs regarding extended criteria. Variety is seen, proving the need for a standardized approach in selection, preferably evidence based. PMID:28732093
Cepeda-Franco, C; Bernal-Bellido, C; Barrera-Pulido, L; Álamo-Martínez, J M; Ruiz-Matas, J H; Suárez-Artacho, G; Marín-Gómez, L M; Tinoco-González, J; Díaz-Aunión, C; Padillo-Ruiz, F J; Gómez-Bravo, M Á
2016-11-01
Recently, there has been a large discrepancy between the number of patients on the waiting list for a liver transplant and the availability of deceased donors, with an increase in annual wait list mortality rates. Elderly donor livers are thought to be marginal grafts; however, in recent years, their utilization has constantly increased. The aim of this study is to evaluate the utilization of elderly donors in Andalusia and post-transplant outcomes. This retrospective observational study of 2408 liver transplants, performed in Andalusia between 2000 and 2014, analyzes the outcomes from donors aged 70 plus (n = 423) in terms of survival rates of the graft and the recipient, the type of transplant, donor age, and D-MELD score (product of donor age and preoperative Model for End-stage Liver Disease score). The most frequent indications for transplant were alcoholic cirrhosis (49.2%), hepatitis C cirrhosis (13%), and hepatocellular carcinoma (12.5%). The overall survival at 5 years was 64%, with a significant fall in survival for recipients with a D-MELD greater than 1500 (57%; P = .045). In the 70-year-old-plus donor group, the overall patient survival was 58.4%. The retransplant rate increased proportionately with donor age. In the alcoholic cirrhosis recipient subgroup, the overall survival at 5 years was 67.6% (P < .05) compared with 33.5% in patients with hepatitis C. Use of elderly donors is a safe strategy to reduce the scarcity of donors, provided that a D-MELD score below 1500 is obtained. Retransplant rates increase progressively with donor age. It is necessary to carefully screen recipients of older organs, taking into account that the best results are obtained for alcoholic cirrhosis, negative viral load hepatitis C, and a D-MELD score below 1500. Copyright © 2016 Elsevier Inc. All rights reserved.