Doppler flowmetry in preeclampsia.
Zahumensky, J
2009-01-01
The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.
Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
NASA Astrophysics Data System (ADS)
Adair, Henry S., III
1998-07-01
Current methods for in vivo evaluation of digital hemodynamics in the horse include angiography, scintigraphy, Doppler ultrasound, electromagnetic flow and isolated extracorporeal pump perfused digit preparations. These techniques are either non-quantifiable, do not allow for continuous measurement, require destruction of the horse orare invasive, inducing non- physiologic variables. In vitro techniques have also been reported for the evaluation of the effects of vasoactive agents on the digital vessels. The in vitro techniques are non-physiologic and have evaluated the vasculature proximal to the coronary band. Lastly, many of these techniques require general anesthesia or euthanasia of the animal. Laser Doppler flowmetry is a non-invasive, continuous measure of capillary blood flow. Laser Doppler flowmetry has been used to measure capillary blood flow in many tissues. The principle of this method is to measure the Doppler shift, that is, the frequency change that light undergoes when reflected by moving objects, such as red blood cells. Laser Doppler flowmetry records a continuous measurement of the red cell motion in the outer layer of the tissue under study, with little or no influence on physiologic blood flow. This output value constitutes the flux of red cells and is reported as capillary perfusion units. No direct information concerning oxygen, nutrient or waste metabolite exchange in the surrounding tissue is obtained. The relationship between the flowmeter output signal and the flux of red blood cells is linear. The principles of laser Doppler flowmetry will be discussed and the technique for laminar capillary blood flow measurements will be presented.
Käser, S. A.; Glauser, P. M.; Maurer, C. A.
2012-01-01
Introduction. In mesenteric infarction due to arterial occlusion, laser Doppler flowmetry and spectrometry are known reliable noninvasive methods for measuring microvascular blood flow and oxygen utilisation. Case Presentation. As an innovation we used these methods in a patient with acute extensive mesenteric infarction due to venous occlusion, occurring after radical right hemicolectomy. Aiming to avoid short bowel syndrome, we spared additional 110 cm of small bowel, instead of leaving only 80 centimetres of clinically viable small bowel in situ. The pathological examination showed only 5 mm of vital mucosa to be left distal to the dissection margin. No further interventions were necessary. Conclusion. Laser doppler flowmetry and spectrometry are potentially powerful methods to assist the surgeon's decision-making in critical venous mesenteric perfusion, thus having an important impact on clinical outcome. PMID:23093968
[Using combined magnetotherapy in patients with acne].
Kul'chitskaia, D B; Orekhova, E M; Vasil'eva, E S
2004-01-01
Laser Doppler flowmetry discovered microcirculatory disorders in acne patients. Affected are arterioles as well as capillaries and venules. Combination of magnetotherapy with medication improves microcirculation in acne patients. More marked positive changes occurred in the microcirculatory system due to combined treatment compared to medication therapy only. Thus, laser Doppler flowmetry is a new, noninvasive method of assessing microcirculation in acne patients and can serve an objective criterion of treatment efficacy.
Efficiency of use endobronchial laser doppler-flowmetry in patients with chronic leukemia
NASA Astrophysics Data System (ADS)
Vanina, E. A.; Voitsekhovskiy, V. V.; Landyshev, Y. S.; Tkacheva, S. I.
2016-11-01
In this work indicatorsendobronchial microcirculation were investigated in patients with chronic myeloid leukemia (CML), chronic lymphocytic leukemia (CLL), multiple myeloma (MM), polycythemia vera (PV), idiopathic myelofibrosis (IMF). A diagnostic bronchoscopy was performed using fibreoptic «Olympus» (Japan).Endobronchial laser Doppler flowmetry was carried out on the laser analyzer capillary blood LAK-02 (Russia). Laser Doppler flowmetry indicators such as parameter of microcirculation, the oscillation amplitude in the endothelial, neurogenic, myogenic, cardiac and respiratory ranges were calculated by continuous the Wavelet transforms. Reduced cardiac and respiratory amplitudes in CML and CLL are primarily due to the development leukostasis. If PV is the case, this is due to sludge syndrome. And when MM occurs, it is caused by protein stasis in the vessels of the bronchial tubes. Increased endothelial oscillation amplitudes in the range in CML, PV, IMF and their reduction in MM indicate the presence of endothelial dysfunction in these patients. Increasing the amplitude of oscillations in the range of neurogenic indicates the development of arteriolar vasodilation as a compensatory response to the violation of blood flow. Increasing the amplitude of oscillations of myogenic tone indicating decrease precapillaries as a compensatory reaction to improve blood flow. It is concluded that endobronchial laser Doppler flowmetry is an important method allowing diagnosing the pathology of the microvasculature of the bronchi in chronic leukemia.
Design of sensors for microcirculation investigation in pharyngeal mucosa
NASA Astrophysics Data System (ADS)
Mareew, Gleb O.; Mareew, Oleg V.; Fedosov, Ivan V.; Tuchin, Valery V.
2004-08-01
Sensors designed for research of blood microcirculation in pharyngeal mucosa by a laser Doppler flowmetry, are described and considered in view of anatomic and physiological features of objects of research. Two designs of sensors for laser Doppler flowmetry are described - non-contact and contact. The results of and clinical testing at norm and different pathologies of pharynx of on calibration of sensors, and also their comparative technical characteristics and materials of clinical researches of microcirculation are resulted at norm and at a various pathology.
Reif, Roberto; Zhi, Zhongwei; Dziennis, Suzan; Nuttall, Alfred L; Wang, Ruikang K
2013-10-01
In this work we determined the contributions of loud sound exposure (LSE) on cochlear blood flow (CoBF) in an in vivo anesthetized mouse model. A broadband noise system (20 kHz bandwidth) with an intensity of 119 dB SPL, was used for a period of one hour to produce a loud sound stimulus. Two techniques were used to study the changes in blood flow, a Doppler optical microangiography (DOMAG) system; which can measure the blood flow within individual cochlear vessels, and a laser Doppler flowmetry (LDF) system; which averages the blood flow within a volume (a hemisphere of ~1.5 mm radius) of tissue. Both systems determined that the blood flow within the cochlea is reduced due to the LSE stimulation.
Raposio, Edoardo; Bertozzi, Nicolò; Moretti, Rebecca; Grignaffini, Eugenio; Grieco, Michele P
2017-07-01
Laser Doppler Flowmetry (LDF) and transcutaneous oximetry (TcpO2) are established methods for investigating cutaneous perfusion. To date, no study previously performed has compared data obtained from these 2 methodologies in cases of chronic cutaneous ulcers. Laser Doppler Flowmetry and TcpO2 were performed in 25 consecutive outpatients with chronic lower limb ulcers (group A, experimental; 9 women and 16 men; mean age 67 years [range, 52-81 years]) and 25 age- and sex-matched healthy control subjects (group B, control) enrolled for the study. Ulcer aetiologies included 12 peripheral arterial occlusive disease, 9 chronic venous insufficiencies, and 4 pressure ulcers. Data were analyzed with Shapiro-Wilk and Wilcoxon-Mann-Whitney tests. A statistically significant difference (P < .05) was found between LDF values of the 2 groups. No statistically significant differences were found between the 2 groups regarding the TcpO2 measurements. The data confirmed the soundness of LDF while investigating local perfusion in patients with chronic cutaneous ulcers. The same diagnostic accuracy was not obtained by means of TcpO2.
NASA Astrophysics Data System (ADS)
Zhang, Ruiying; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2013-08-01
We propose a method for photoacoustic flow measurement based on the Doppler effect from a flowing homogeneous medium. Excited by spatially modulated laser pulses, the flowing medium induces a Doppler frequency shift in the received photoacoustic signals. The frequency shift is proportional to the component of the flow speed projected onto the acoustic beam axis, and the sign of the shift reflects the flow direction. Unlike conventional flowmetry, this method does not rely on particle heterogeneity in the medium; thus, it can tolerate extremely high particle density. A red-ink phantom flowing in a tube immersed in water was used to validate the method in both the frequency and time domains. The phantom flow immersed in an intralipid solution was also measured.
NASA Astrophysics Data System (ADS)
Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.
2016-04-01
Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.
Optical characteristics of modified fiber tips in single fiber, laser Doppler flowmetry
NASA Astrophysics Data System (ADS)
Oberg, P. Ake; Cai, Hongming; Rohman, Hakan; Larsson, Sven-Erik
1994-02-01
Percutaneous laser Doppler flowmetry (LDF) and bipolar surface electromyography (EMG) were used simultaneously for measurement of skeletal muscle (trapezius) perfusion in relation to static load and fatigue. On-line computer (386 SX) processing of the LDF- and EMG- signals made possible interpretation of the relationship between the perfusion and the activity of the muscle. The single fiber laser Doppler technique was used in order to minimize the trauma. A ray-tracing program was developed in the C language by which the optical properties of the fiber and fiber ends could be simulated. Isoirradiance graphs were calculated for three fiber end types and the radiance characteristics were measured for each fiber end. The three types of fiber-tips were evaluated and compared in flow model measurements.
Lantsberg, L; Goldman, M
1991-04-01
The level of amputation continues to present a challenge for surgeons. In view of this, 24 patients who required an amputation of their ischaemic leg were studied prospectively using Laser Doppler flowmetry (LDF), TcpO2 measurements and Doppler ultrasound to assess the best level for amputation. In all patients gangrene of the leg and rest pain were the indication for an amputation. Skin oxygen tension (TcpO2) and skin blood flow (LDF) measurements were obtained the day before surgery on the proposed anterior and posterior skin flaps for below knee amputation and the maximum Doppler systolic pressure was measured. The level of amputation was chosen at surgery by clinical judgement without reference to the measurements mentioned above. A below knee amputation was performed in 17 patients and an above knee in seven. All amputations healed by primary intention. Doppler pressures showed poor discrimination with a median value of 10 mmHg (0-25) in AK patients and 35 mmHg (0-85) in the BK group (p greater than 0.05). In contrast TcpO2 showed a trend. In the BK group the median value was 20 mmHg (4-50) on the anterior and 22 mmHg (2-60) on the posterior flap compared to above knee amputees with median values of 6 mmHg (2-11) and 8 mmHg (3-38), respectively (p greater than 0.05). Laser Doppler seemed more useful. In BK patients the median LDF values were 36 mV (20-85) on the anterior and 34 mV (20-80) on the posterior flap with median LDF values of 10 mV (10-18) on the anterior and 11 mV (8-38) on the posterior flap in the above knee group (p less than 0.01). Laser Doppler flowmetry is a simple objective test, which is a better discriminator of skin flap perfusion than either TcpO2 or Doppler ankle pressures.
Photoacoustic Doppler effect from flowing small light-absorbing particles.
Fang, Hui; Maslov, Konstantin; Wang, Lihong V
2007-11-02
From the flow of a suspension of micrometer-scale carbon particles, the photoacoustic Doppler shift is observed. As predicted theoretically, the observed Doppler shift equals half of that in Doppler ultrasound and does not depend on the direction of laser illumination. This new physical phenomenon provides a basis for developing photoacoustic Doppler flowmetry, which can potentially be used for detecting fluid flow in optically scattering media and especially low-speed blood flow of relatively deep microcirculation in biological tissue.
NASA Astrophysics Data System (ADS)
Volkov, M. V.; Kostrova, D. A.; Margaryants, N. B.; Gurov, I. P.; Erofeev, N. P.; Dremin, V. V.; Zharkikh, E. V.; Zherebtsov, E. A.; Kozlov, I. O.; Dunaev, A. V.
2017-03-01
Laser Doppler flowmetry (LDF) is widely used for diagnosing blood microcirculation diseases. It is well known that the Doppler shift of laser radiation scattered by moving red blood cells (RBC) can be assessed through analyzing photocurrent produced by a photodetector. LDF signal contains information about regulating blood flow rhythms: myogenic, cardiac, nervous and endothelial. The method of videocapillaroscopy (VCS) allows local capillary blood flow velocity evaluation and, using video data processing algorithms, is able to assess RBC velocity changes into capillary. We present the results of simultaneous investigations of changes in tissue perfusion of the distal phalanx of human finger by the LDF as well as changes in capillary blood flow velocity in the nail bed evaluated by the VCS method during arterial occlusion test. The experimental results confirmed the correspondence between blood perfusion and blood flow velocity.
Laser Doppler flowmetry evaluation of gingival recovery response after laser treatment
NASA Astrophysics Data System (ADS)
Todea, Carmen; Cânjǎu, Silvana; Dodenciu, Dorin; Miron, Mariana I.; Tudor, Anca; Bǎlǎbuc, Cosmin
2013-06-01
This study was performed in order to evaluate in vivo the applicability of Laser Doppler Flowmetry (LDF) in recording the gingival blood flow and to assess the changes of gingival blood flow following gingival reshaping performed with Er:YAG and 980 nm diode lasers. The LDF evaluation was performed on 20 anterior teeth, which underwent reshaping of gingiva, corresponding to 5 female patients (4 anterior teeth/patient), aged between 20 and 35. One part of the mouth was treated with Er:YAG laser (LP, VLP modes, 140 - 250 mJ, 10 - 20 Hz, using cylindrical sapphire tips) and other part with 980 nm diode laser (CW, 4 W, contact mode and saline solution cooling). The gingival blood flow was monitored using a MoorLab laser Doppler equipment (Moor Instruments Ltd., Axminster, UK) with a straight optical probe, MP3b, 10 mm. The data were processed using statistical analysis software SPSS v16.0.1. The investigation showed an evident decrease in perfusion for both areas in comparison with the baseline values 24 hours after treatment. The microvascular blood flow increased significantly after 7 days in both areas but mostly in diode area (p<0.001). After 14 days for the Er:YAG area the blood perfusion returned to the initial value. The results in diode area remained at a high level after 14 days. Both lasers proved efficiency in the surgical treatment of gingival tissue. Moreover, Laser Doppler Flowmetry is adequate for recording changes in gingival blood flow following periodontal surgery.
An endoscopic laser Doppler flowmetry of a gastroduodenal mucosa at bleeding ulcer
NASA Astrophysics Data System (ADS)
Shapkin, U. G.; Kapralov, C. V.; Gogolev, A. A.; Lychagov, V. V.; Tuchin, V. V.
2006-08-01
One of the important problems of a bleeding gastroduodenal ulcer surgery is a prognosis of the recurrent hemorrhage and appraisal of endoscopic hemostasis quality. Endoscopic Laser Doppler Flowmetry of a mucous coat of stomach and a duodenum was made on 34 patients for the purpose of investigation of features of microcirculation. Analogous researches are made on 30 patients with a peptic ulcer and on 28 practically healthy people. Analysis of LDF-grams has shown certain differences in regional microcirculations in stomach and duodenal at normal and at a pathology. Increase of regional perfusion in periulcerose zone with its pathology disbalance can serve as a criterion for activities of an alteration processes in gastroduodenal ulcer defining the risk of possible hemorrhage.
Bishai, John M; Blood, Arlin B; Hunter, Christian J; Longo, Lawrence D; Power, Gordon G
2003-01-01
This study was undertaken to compare microsphere and laser Doppler flowmetry techniques for the measurement of cerebral blood flow, to assess the effect of probe implantation at the tip of the sensing probe and to measure brain tissue PO2 (tPO2) in response to acute hypoxia. Fetal sheep of ≈131 days gestation (n = 8) were chronically instrumented with bilateral laser Doppler probes in the parietal cortices and catheters for injection of fluorescent microspheres. Five days after surgery fetuses were subjected to 1 h periods of baseline control breathing, hypoxia and recovery. Microspheres were injected 10 min prior to and 10, 30, 50 and 120 min after initiation of hypoxia. Microspheres were counted in four 12 mm3 tissue samples from each hemisphere, the tip of the laser Doppler probe being positioned in the centre of one of the cubes. The cube containing the probe tip was also subdivided into 4 mm3 pieces of tissue. In response to hypoxia, fetal arterial PO2 declined from 21 ± 2 to 12 ± 1 Torr and brain tissue PO2 fell from 10 ± 1 to a nadir of 1 ± 1 Torr. Each method detected a significant increase in CBF that reached a maximum after 30–45 min, although the increase of flow measured by laser Doppler flowmetry was less than that measured by spheres after 10 and 30 min (P < 0.05). Microspheres did not detect altered flow at the probe tip or heterogeneity of flow in surrounding volumes of cortical tissue. In summary, laser Doppler flowmetry is a useful measure of continuous relative changes of CBF in the chronically instrumented fetal sheep. Flow compensations in acute hypoxia are not adequate to sustain O2 delivery, and other compensations, including reduced metabolic rate, are possible. PMID:12563011
NASA Astrophysics Data System (ADS)
Todea, Carmen; Sarpe, Amalia; Vitez, Bogdan; Draganescu, Gheorghe
2014-01-01
The present study aims to assess the pulp vitality before and after different tooth bleaching procedures, in order to determine the changes in pulpal microcirculation and whether they are reversible or not. Twelve volunteers were included in this study. For each volunteer, the pulpal blood flow of maxillary teeth was assessed prior to treatment using Laser Doppler Flowmetry. The "in office" bleaching technique was used 6 anterior teeth, with two different gels, a conventional one chemically activated (Group I 3teeth) and another one activated using Nd:YAG laser (Group II-3 teeth). The bleaching agents were applied on counterpart teeth and, after obtaining a esthetic results for each tooth, the pulpal blood flow was assessed using Laser Doppler Flowmetry immediately after treatment and then after one day and one week. All data were collected and statistically analyzed. Immediately after treatment, the assessment showed an increase of pulpal blood flow, for both study groups, but higher in Group I as compared to Group II (p<0.005). The subsequent assessments showed a reduction of the pulpal blood flow with non - significant differences between the study groups (p<0.005).The results suggest that the tooth bleaching procedurere presents a safe treatment method, which does not lead to irreversible damage to the dental pulp, when used correctly.
NASA Astrophysics Data System (ADS)
Kapralov, S. V.; Shapkin, Y. G.; Lychagov, V. V.; Tuchin, V. V.
2007-05-01
One of the most complex problems of emergency surgery is the choice of surgical tactics to deal with bleeding peptic ulcer. Endoscopic hemostasis is prescribed to patients with continuing bleedings and prerelapse syndrome. But till nowdays the objective verification of the prerelapse condition had not been worked out. What is more there are no objective criteria to judge the effectiveness of the carried endohemostasis. The aim of the study was to work out a new objective diagnostic method of pre-recurrence syndrome that can be able to make prognosis for possible gastroduodenal ulcer bleeding recurrence more precise. Laser Doppler flowmetry was the method of studies the regional perfusion. The device used in this work was made at the Optics and Biophysics Department of Saratov State University.
Zherebtsov, Evgeny A; Zherebtsova, Angelina I; Doronin, Alexander; Dunaev, Andrey V; Podmasteryev, Konstantin V; Bykov, Alexander; Meglinski, Igor
2017-04-01
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system.
The effect of prazosin on skin microcirculation as assessed by laser Doppler flowmetry.
Khan, F; Struthers, A D; Spence, V A
1988-01-01
1. Laser Doppler flowmetry was used in six normal volunteers to record changes in fingertip skin blood flow after the administration of prazosin to block postsynaptic alpha 1-adrenoceptors. 2. Prazosin (0.5 mg orally) did not alter systolic or diastolic blood pressure or heart rate. 3. Prazosin did significantly increase basal skin blood flow 2 h after its administration but this effect was no longer evident after contralateral hand warming. Prazosin markedly reduced the skin vasoconstrictor response to deep inspiration and to contralateral hand cooling. 4. This study suggests that postsynaptic alpha 1-adrenoceptors are involved in maintaining skin vasoconstrictor tone at rest and are also involved in the rapid skin vasoconstriction seen in response to a deep inspiration and to contralateral hand cooling. PMID:2846022
NASA Astrophysics Data System (ADS)
Zherebtsov, Evgeny A.; Zherebtsova, Angelina I.; Doronin, Alexander; Dunaev, Andrey V.; Podmasteryev, Konstantin V.; Bykov, Alexander; Meglinski, Igor
2017-04-01
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system.
Investigation of Doppler spectra of laser radiation scattered inside hand skin during occlusion test
NASA Astrophysics Data System (ADS)
Kozlov, I. O.; Zherebtsov, E. A.; Zherebtsova, A. I.; Dremin, V. V.; Dunaev, A. V.
2017-11-01
Laser Doppler flowmetry (LDF) is a method widely used in diagnosis of microcirculation diseases. It is well known that information about frequency distribution of Doppler spectrum of the laser radiation scattered by moving red blood cells (RBC) usually disappears after signal processing procedure. Photocurrent’s spectrum distribution contains valuable diagnostic information about velocity distribution of the RBC. In this research it is proposed to compute the indexes of microcirculation in the sub-ranges of the Doppler spectrum as well as investigate the frequency distribution of the computed indexes.
Raisis, A L; Young, L E; Taylor, P M; Walsh, K P; Lekeux, P
2000-03-01
To use Doppler ultrasonography and single-fiber laser Doppler flowmetry (LDF) to evaluate blood flow in the dependent and nondependent hind limbs of anesthetized horses and to evaluate changes in femoral arterial blood flow and microvascular skeletal muscle perfusion in response to administration of phenylephrine hydrochloride or dobutamine hydrochloride. 6 healthy adult horses. Horses were anesthetized and positioned in left lateral recumbency. Doppler ultrasonography was used to measure velocity and volumetric flow in the femoral vessels. Single-fiber LDF was used to measure relative microvascular perfusion at a single site in the semimembranosus muscles. Phenylephrine or dobutamine was then administered to decrease or increase femoral arterial blood flow, and changes in blood flow and microvascular perfusion were recorded. Administration of phenylephrine resulted in significant decreases in femoral arterial and venous blood flows and cardiac output and significant increases in mean aortic blood pressure, systemic vascular resistance, and PCV. Administration of dobutamine resulted in significant increases in femoral arterial blood flow, mean aortic blood pressure, and PCV. Significant changes in microvascular perfusion were not detected. Results suggest that Doppler ultrasonography and single-fiber LDF can be used to study blood flows in the hind limbs of anesthetized horses. However, further studies are required to determine why changes in femoral arterial blood flows were not associated with changes in microvascular perfusion.
Relationship of oscillating and average components of laser Doppler flowmetry signal
NASA Astrophysics Data System (ADS)
Mizeva, Irina; Frick, Peter; Podtaev, Sergey
2016-08-01
Signals from laser Doppler flowmeters widely used in intravital studies of skin blood flow include, along with a slowly varying average component, an oscillating part. However, in most clinical studies, pulsations are usually smoothed by data preprocessing and only the mean blood flow is analyzed. To reveal the relationship between average and oscillating perfusion components measured by a laser Doppler flowmeter, we examined the microvascular response to the contralateral cold pressor test recorded at two different sites of the hand: dorsal part of the arm and finger pad. Such a protocol makes it possible to provide a wide range of perfusion. The average perfusion always decreases during cooling, while the oscillating component demonstrates a differently directed response. The wavelet analysis of laser Doppler flowmetry (LDF) signals shows that the pulsatile component is nonlinearly related to the average perfusion. Under low perfusion, the amplitude of pulsations is proportional to its mean value, but, as perfusion increases, the amplitude of pulsations becomes lower. The type of response is defined by the basal perfusion and the degree of vasoconstriction caused by cooling. Interpretation of the results is complicated by the nonlinear transfer function of the LDF device, the contribution of which is studied using artificial examples.
Adaptation of laser-Doppler flowmetry to measure cerebral blood flow in the fetal sheep.
Lan, J; Hunter, C J; Murata, T; Power, G G
2000-09-01
The purpose of this study was to devise a means to use laser-Doppler flowmetry to measure cerebral perfusion before birth. The method has not been used previously, largely because of intrauterine movement artifacts. To minimize movement artifacts, a probe holder was molded from epoxy putty to the contour of the fetal skull. A curved 18-gauge needle was embedded in the holder. At surgery, the holder, probe, and skull were fixed together with tissue glue. Residual signals were recorded after fetal death and after maternal death 1 h later. These averaged <5% of baseline flow signals, indicating minimal movement artifact. To test the usefulness of the method, cerebral flow responses were measured during moderate fetal hypoxia induced by giving the ewes approximately 10% oxygen in nitrogen to breathe. As fetal arterial PO(2) decreased from 21.1 +/- 0.5 to 10.7 +/- 0.4 Torr during a 30-min period, cerebral perfusion increased progressively to 56 +/- 8% above baseline. Perfusion then returned to baseline levels during a 30-min recovery period. These responses are quantitatively similar to those spot observations that have been recorded earlier using labeled microspheres. We conclude that cerebral perfusion can be successfully measured by using laser-Doppler flowmetry with the unanesthetized, chronically prepared fetal sheep as an experimental model. With this method, relative changes of perfusion from a small volume of the ovine fetal brain can be measured on a continuous basis, and movement artifacts can be reduced to 5% of measured flow values.
The MOST - Monitor for Oxygenation of Surface and Tissue.
1995-10-01
CAT Reduce need for ICU, low risk groups Central nursing station Office procedures: Dentistry , Endoscopy Monitoring spinal or epidural narcotics Home...obtainable by using laser Doppler methods (Wickramasinghe et al., 1994; Liepsch et al., 1993; Mendelson, Ochs, 1988). While many parameters beyond oxygenation...blood flow include laser Doppler flowmetry sys- tems which are currently commercially available. These systems measure the velocity of blood particles
Evaluation of gingival vascularisation using laser Doppler flowmetry
NASA Astrophysics Data System (ADS)
Vitez, B.; Todea, C.; Velescu, A.; Şipoş, C.
2016-03-01
Aim: The present study aims to assess the level of vascularisation of the lower frontal gingiva of smoker patients, in comparison with non-smokers by using Laser Doppler Flowmetry (LDF), in order to determine the changes in gingival microcirculation. Material & methods: 16 volunteers were included in this study and separated into 2 equal groups: non-smoker subjects in Group I and smoker subjects in Group II. All patients were submitted to a visual examination and professional cleaning The gingival bloodflow of each patient was recorded in 5 zones using LDF, resulting in a total of 80 recordings. LDF was done with the Moor Instruments Ltd. "moorLAB" Laser Doppler. All data were collected as graphs, raw values and statistically analyzed. Results: After strict analysis results show that Group II presents a steady level of gingival microcirculation with even patterns in the graph, while Group I shows many signs of damage to it`s microvascular system through many irregularities in the microcirculation level and graph patterns. Conclusion: The results suggest that prolonged smoking has a definitive effect on the gingival vascularisation making it a key factor in periodontal pathology.
[Microcirculation in patients with paranoid schizophrenia].
Sakharov, A V; Ozornin, A S; Golygina, S E; Vinogradova, A O; Shvets, M S
2018-01-01
To study microcirculation in patients with paranoid schizophrenia by laser Doppler flowmetry. Fifty-three patients at the age from 18 to 38 years with a diagnosis of 'paranoid schizophrenia' (F20.0) were examined in the acute psychotic state and after 3 weeks of therapy. The control group consisted of 20 healthy volunteers. To assess microcirculation, the noninvasive technique of laser Doppler flowmetry using a laser blood flow analyzer was used. Significant changes in the microcirculation persisting even over three weeks of therapy in patients were identified. The total microcirculation index was increased by 1.4 times which indicated the acceleration of blood flow. An increase in the average fluctuations of perfusion by 3.7 times and in the coefficient of variation by 1.9 times, which reflect the excessive strengthening of local mechanisms of regulation of microcirculation, were found. There were an increase in the myogenic tone and neurogenic tone of metarteriole and precapillary sphincters as well as bypass index.
Medical Electronics and Physiological Measurement.
ERIC Educational Resources Information Center
Cochrane, T.
1989-01-01
Described are developments in medical electronics and physiological measurement. Discussed are electrocardiology, audiology, and urology as mature applications; applied potential tomography, magnetic stimulation of nerves, and laser Doppler flowmetry as new techniques; and optical sensors, ambulatory monitoring, and biosensors as future…
Bioengineering assessment of acupuncture, part 8: innovative moxibustion.
Litscher, Gerhard
2010-01-01
The actual Chinese character for acupuncture, translated literally, means "acupuncture-moxibustion." This shows the enormous importance of moxibustion in Asia for thousands of years. In this review article, the history of the burning of mugwort (moxatherapy) is briefly described. In addition, new technical methods such as new infrared-moxa or laser-moxa devices, electrobian stone moxibustion, and the investigations of a new needle-moxa system using high-tech methods such as thermography, laser Doppler flowmetry, and laser Doppler imaging are presented.
Spectral analysis of the microcirculatory laser Doppler signal at the Hoku acupuncture point.
Hsiu, Hsin; Hsu, Wei-Chen; Huang, Shih-Ming; Hsu, Chia-Liang; Lin Wang, Yuh-Ying
2009-05-01
We aimed to characterize the frequency spectra of skin blood flow signals recorded at Hoku, an important acupuncture point (acupoint) in oriental medicine. Electrocardiogram (ECG) and laser Doppler flowmetry signals were measured simultaneously in 31 trials on seven volunteers aged 21-27 years. A four-level Haar wavelet transform was applied to the measured 20 min laser Doppler flowmetry (LDF) signals, and periodic oscillations with five characteristic frequency peaks were obtained within the following frequency bands: 0.0095-0.021 Hz, 0.021-0.052 Hz, 0.052-0.145 Hz, 0.145-0.6 Hz, and 0.6-1.6 Hz (defined as FR1-FR5), respectively. The relative energy contribution in FR3 was significantly larger at Hoku than at the two non-acupoints. Linear regression analysis revealed that the relative energy contribution in FR3 at Hoku significantly increased with the pulse pressure (R(2) = 0.48; P < 0.01 by F-test). Spectral analysis of the flux signal revealed that one of the major microcirculatory differences between acupoints and non-acupoints was in the different myogenic responses of their vascular beds. This information may aid the development of a method for the non-invasive study of the microcirculatory characteristics of the acupoint.
Rohleder, Nils H; Flensberg, Sandra; Bauer, Florian; Wagenpfeil, Stefan; Wales, Craig J; Koerdt, Steffen; Wolff, Klaus D; Hölzle, Frank; Steiner, Timm; Kesting, Marco R
2014-03-01
Microcirculation and oxygen supply in cervical skin were measured with an optical, noninvasive method in patients with or without radiotherapy before neck dissection. The course of wound healing was monitored after the surgical procedure to identify predictive factors for postoperative wound healing disorders. Tissue spectrophotometry and laser Doppler flowmetry were used to determine capillary oxygen saturation, hemoglobin concentration, blood flow, and blood velocity at 2-mm and 8-mm depths in the cervical skin of 91 patients before neck dissection in a maxillofacial unit of a university hospital in Munich, Germany. Parameters were evaluated for differences between patients with irradiation (24) and without (67) and patients with wound healing disorders (25) and without (66) (univariate or multivariate statistical analyses). Velocity at 2 mm was lower in irradiated skin (P = .016). Flow at 2 mm was higher in patients with wound healing disorders (P = .018). High flow values could help to identify patients at risk for cervical wound healing disorders. Copyright © 2014 Elsevier Inc. All rights reserved.
Brothers, R. Matthew; Wingo, Jonathan E.; Hubing, Kimberly A.
2010-01-01
Skin blood flow responses in the human forearm, assessed by three commonly used technologies—single-point laser-Doppler flowmetry, integrated laser-Doppler flowmetry, and laser-Doppler imaging—were compared in eight subjects during normothermic baseline, acute skin-surface cooling, and whole body heat stress (Δ internal temperature = 1.0 ± 0.2°C; P < 0.001). In addition, while normothermic and heat stressed, subjects were exposed to 30-mmHg lower-body negative pressure (LBNP). Skin blood flow was normalized to the maximum value obtained at each site during local heating to 42°C for at least 30 min. Furthermore, comparisons of forearm blood flow (FBF) measures obtained using venous occlusion plethysmography and Doppler ultrasound were made during the aforementioned perturbations. Relative to normothermic baseline, skin blood flow decreased during normothermia + LBNP (P < 0.05) and skin-surface cooling (P < 0.01) and increased during whole body heating (P < 0.001). Subsequent LBNP during whole body heating significantly decreased skin blood flow relative to control heat stress (P < 0.05). Importantly, for each of the aforementioned conditions, skin blood flow was similar between the three measurement devices (main effect of device: P > 0.05 for all conditions). Similarly, no differences were identified across all perturbations between FBF measures using plethysmography and Doppler ultrasound (P > 0.05 for all perturbations). These data indicate that when normalized to maximum, assessment of skin blood flow in response to vasoconstrictor and dilator perturbations are similar regardless of methodology. Likewise, FBF responses to these perturbations are similar between two commonly used methodologies of limb blood flow assessment. PMID:20634360
Brothers, R Matthew; Wingo, Jonathan E; Hubing, Kimberly A; Crandall, Craig G
2010-09-01
Skin blood flow responses in the human forearm, assessed by three commonly used technologies-single-point laser-Doppler flowmetry, integrated laser-Doppler flowmetry, and laser-Doppler imaging-were compared in eight subjects during normothermic baseline, acute skin-surface cooling, and whole body heat stress (Δ internal temperature=1.0±0.2 degrees C; P<0.001). In addition, while normothermic and heat stressed, subjects were exposed to 30-mmHg lower-body negative pressure (LBNP). Skin blood flow was normalized to the maximum value obtained at each site during local heating to 42 degrees C for at least 30 min. Furthermore, comparisons of forearm blood flow (FBF) measures obtained using venous occlusion plethysmography and Doppler ultrasound were made during the aforementioned perturbations. Relative to normothermic baseline, skin blood flow decreased during normothermia+LBNP (P<0.05) and skin-surface cooling (P<0.01) and increased during whole body heating (P<0.001). Subsequent LBNP during whole body heating significantly decreased skin blood flow relative to control heat stress (P<0.05). Importantly, for each of the aforementioned conditions, skin blood flow was similar between the three measurement devices (main effect of device: P>0.05 for all conditions). Similarly, no differences were identified across all perturbations between FBF measures using plethysmography and Doppler ultrasound (P>0.05 for all perturbations). These data indicate that when normalized to maximum, assessment of skin blood flow in response to vasoconstrictor and dilator perturbations are similar regardless of methodology. Likewise, FBF responses to these perturbations are similar between two commonly used methodologies of limb blood flow assessment.
Kaner, Dogan; Zhao, Han; Terheyden, Hendrik; Friedmann, Anton
2015-06-01
We investigated the effect of soft tissue expansion (STE) on vertical ridge augmentation with regard to the incidence of wound dehiscences and the impairment of microcirculation in dogs, and the applicability of laser Doppler flowmetry (LDF) to explore the relation between microcirculation and wound healing. Bone defects were created on both mandibular sides in ten beagle dogs by extraction of premolars and removal of bone. Six weeks later, self-filling tissue expanders were implanted in randomly assigned test sites. After 5 weeks of expansion, vertical augmentation was carried out in test and control sites using calvarial onlay grafts side by side with granular biphasic calcium phosphate covered with a resorbable polyethylene glycol membrane. Microcirculation was evaluated with laser Doppler flowmetry (LDF). The incidence of wound dehiscences was evaluated after 2 weeks. The validity of LDF to predict dehiscences was evaluated by construction of receiver operating characteristic (ROC) curves. After augmentation, test sites showed significantly better perfusion than control sites without preceding STE (P = 0.012). Three days after surgery, perfusion was still significantly decreased in control sites (P = 0.005), while microcirculation in test sites had returned to pre-surgical levels. After 2 weeks, healing in test sites was good, whereas eight dehiscences were found in control sites (P = 0.002). ROC curves showed that microcirculation levels immediately after augmentation surgery significantly predicted subsequent wound dehiscences (AUC = 0.799, CI 0.642-0.955, P = 0.006). Laser Doppler flowmetry is suitable for evaluation of soft tissue microcirculation after ridge augmentation. STE reduced the impairment of microcirculation caused by vertical ridge augmentation and decreased the incidence of wound dehiscences in the investigated animal model. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum
2007-06-01
To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible method of tumor perfusion surveillance than comparison of single representative tumor sections. (c) RSNA, 2007.
Novel laser Doppler flowmeter for pulpal blood flow measurements
NASA Astrophysics Data System (ADS)
Zang, De Yu; Millerd, James E.; Wilder-Smith, Petra B. B.; Arrastia-Jitosho, Anna-Marie A.
1996-04-01
We have proposed and experimentally demonstrated a new configuration of laser Doppler flowmetry for dental pulpal blood flow measurements. To date, the vitality of a tooth can be determined only by subjective thermal or electric tests, which are of questionable reliability and may induced pain in patient. Non-invasive techniques for determining pulpal vascular reactions to injury, treatment, and medication are in great demand. The laser Doppler flowmetry technique is non-invasive; however, clinical studies have shown that when used to measure pulpal blood flow the conventional back-scattering Doppler method suffers from low signal-to-noise ratio (SNR) and unreliable flux readings rendering it impossible to calibrate. A simplified theoretical model indicates that by using a forward scattered geometry the detected signal has a much higher SNR and can be calibrated. The forward scattered signal is readily detectable due to the fact that teeth are relatively thin organs with moderate optical loss. A preliminary experiment comparing forward scattered detection with conventional back- scattered detection was carried out using an extracted human molar. The results validated the findings of the simple theoretical model and clearly showed the utility of the forward scattering geometry. The back-scattering method had readings that fluctuated by as much as 187% in response to small changes in sensor position relative to the tooth. The forward scattered method had consistent readings (within 10%) that were independent of the sensor position, a signal-to-noise ratio that was at least 5.6 times higher than the back-scattering method, and a linear response to flow rate.
NASA Astrophysics Data System (ADS)
Assous, S.; Humeau, A.; Tartas, M.; Abraham, P.; L'Huillier, J. P.
2005-05-01
Conventional signal processing typically involves frequency selective techniques which are highly inadequate for nonstationary signals. In this paper, we present an approach to perform time-frequency selective processing of laser Doppler flowmetry (LDF) signals using the S-transform. The approach is motivated by the excellent localization, in both time and frequency, afforded by the wavelet basis functions. Suitably chosen Gaussian wavelet functions are used to characterize the subspace of signals that have a given localized time-frequency support, thus enabling a time-frequency partitioning of signals. In this paper, the goal is to study the influence of various pharmacological substances taken by the oral way (celecobix (Celebrex®), indomethacin (Indocid®) and placebo) on the physiological activity behaviour. The results show that no statistical differences are observed in the energy computed from the time-frequency representation of LDF signals, for the myogenic, neurogenic and endothelial related metabolic activities between Celebrex and placebo, and Indocid and placebo. The work therefore proves that these drugs do not affect these physiological activities. For future physiological studies, there will therefore be no need to exclude patients having taken cyclo-oxygenase 1 inhibitions.
Skin perfusion evaluation between laser speckle contrast imaging and laser Doppler flowmetry
NASA Astrophysics Data System (ADS)
Humeau-Heurtier, Anne; Mahe, Guillaume; Durand, Sylvain; Abraham, Pierre
2013-03-01
In the biomedical field, laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) are two optical techniques aiming at monitoring - non-invasively - the microvascular blood perfusion. LDF has been used for nearly 40 years whereas LSCI is a recent technique that overcomes some drawbacks of LDF. Both LDF and LSCI give perfusion assessments in arbitrary units. However, the possible relationship existing between perfusions given by LDF and by LSCI over large blood flow values has not been completely studied yet. We therefore herein evaluate the relationship between the LDF and LSCI perfusion values across a broad range of skin blood flows. For this purpose, LDF and LSCI data were acquired simultaneously on the forearm of 12 healthy subjects, at rest, during different durations of vascular occlusion and during reactive hyperemia. For the range of skin blood flows studied, the power function fits the data better than the linear function: powers for individual subjects go from 1.2 to 1.7 and the power is close to 1.3 when all the subjects are studied together. We thus suggest distinguishing perfusion values given by the two optical systems.
Multifractal spectra of laser Doppler flowmetry signals in healthy and sleep apnea syndrome subjects
NASA Astrophysics Data System (ADS)
Buard, Benjamin; Trzepizur, Wojciech; Mahe, Guillaume; Chapeau-Blondeau, François; Rousseau, David; Gagnadoux, Frédéric; Abraham, Pierre; Humeau, Anne
2009-07-01
Laser Doppler flowmetry (LDF) signals give a peripheral view of the cardiovascular system. To better understand the possible modifications brought by sleep apnea syndrome (SAS) in LDF signals, we herein propose to analyze the complexity of such signals in obstructive SAS subjects, and to compare the results with those obtained in healthy subjects. SAS is a pathology that leads to a drop in the parasympathetic tone associated with an increase in the sympathetic tone in awakens SAS patients. Nine men with obstructive SAS and nine healthy men participated awaken in our study and LDF signals were recorded in the forearm. In our work, complexity of LDF signals is analyzed through the computation and analysis of their multifractal spectra. The multifractal spectra are estimated by first estimating the discrete partition function of the signals, then by determining their Renyi exponents with a linear regression, and finally by computing their Legendre transform. The results show that, at rest, obstructive SAS has no or little impact on the multifractal spectra of LDF signals recorded in the forearm. This study shows that the physiological modifications brought by obstructive SAS do not modify the complexity of LDF signals when recorded in the forearm.
Laser Doppler flowmetry in endodontics: a review.
Jafarzadeh, H
2009-06-01
Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.
Modeling and processing of laser Doppler reactive hyperaemia signals
NASA Astrophysics Data System (ADS)
Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre
2003-07-01
Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.
Ishikawa, H; Iwasaki, H; Tsukada, H; Chu, S; Nakamura, S; Yamamoto, K
1999-09-01
This report presents two cases of isolated cleft palate with asymmetric distribution of postsurgical scar tissue determined by laser Doppler flowmetry. To determine the effect of mucoperiosteal denudation of the bone on maxillary alveolar growth, the analysis of dentoalveolar structures compared the affected side to the unaffected side of each case. Two Japanese girls with isolated cleft palates were examined. Both subjects had undergone pushback operations (a modified version of the procedure of Wardill) for palatal repair at 18 months of age. Palatal blood flow was examined by laser Doppler flowmetry when the girls were 12 years old to determine the extent of postsurgical scar tissue over the denuded bone. To analyze the maxillary dentoalveolar structures three dimensionally, the whole surface of the upper dental cast was measured and recorded by an optical measuring device when the girls were 7 years old. Analysis via flowmetry showed that the palatal scar tissue area was limited to the anterior tooth region on the right (unaffected) side but extended posteriorly to the premolar region on the left (affected) side in both subjects. The two girls had similar dentoalveolar structures, with the dental and alveolar arches deflected lingually at the deciduous molar area on the affected side. There were no differences in the buccolingual inclination of deciduous molars or in the vertical growth of the alveolar processes between the affected and unaffected sides. In both girls, bone denudation in the premolar region appeared to result in less than 3 mm of displacement of the teeth palatally, with no change in lingual inclination. Any effects of scar tissue on the vertical development of the alveolus were not substantiated.
Comparative laser Doppler measurement on tooth pulp blood flow at 632 and 750 nm
NASA Astrophysics Data System (ADS)
Oberg, P. Ake; Pettersson, Hans; Rohman, Hakan
1993-12-01
Laser-Doppler flowmetry has been used for the assessment of pulp blood flow in health and disease. General purpose laser Doppler instruments working at the Helium-Neon (632,8 nm) as well as IR (750 - 810 nm) wavelengths have been used in this application. Specially designed handheld equipment has also been used to assess blood supply to the tooth. A considerable difference in the measurement results have been noticed when using different wavelengths and probe designs. In this study some of the problems related to the use of various wavelengths and probe designs are studied in human teeth and in a physical model of a tooth. Our results support the early observation that measurements at different wavelengths and with different probe designs cannot be directly compared.
Lantsberg, L; Goldman, M
1990-01-01
In a retrospective study of critical ischaemia of the lower limb, sympathectomy appeared to be of value in the majority of patients. We therefore assessed sympathectomy by measuring skin blood flow before and after the procedure using laser Doppler flowmetry (LDF) and transcutaneous oxygen tension (TCpO2) techniques. Twenty patients underwent chemical sympathectomy and there was one surgical procedure. Measurements were performed before and 1 week after sympathectomy below the knee and on the forefoot. Symptomatic improvement occurred in 20 of 21 patients. This study demonstrates that skin blood flow in the leg and foot is improved by sympathectomy and confirms objectively our clinical impression.
Binzoni, Tiziano; Torricelli, Alessandro; Giust, Remo; Sanguinetti, Bruno; Bernhard, Paul; Spinelli, Lorenzo
2014-01-01
A bone tissue phantom prototype allowing to test, in general, optical flowmeters at large interoptode spacings, such as laser-Doppler flowmetry or diffuse correlation spectroscopy, has been developed by 3D-stereolithography technique. It has been demonstrated that complex tissue vascular systems of any geometrical shape can be conceived. Absorption coefficient, reduced scattering coefficient and refractive index of the optical phantom have been measured to ensure that the optical parameters reasonably reproduce real human bone tissue in vivo. An experimental demonstration of a possible use of the optical phantom, utilizing a laser-Doppler flowmeter, is also presented. PMID:25136496
Jones, Phill B.; Shin, Hwa Kyoung; Boas, David A.; Hyman, Bradley T.; Moskowitz, Michael A.; Ayata, Cenk; Dunn, Andrew K.
2009-01-01
Real-time investigation of cerebral blood flow (CBF), and oxy- and deoxyhemoglobin concentration (HbO, HbR) dynamics has been difficult until recently due to limited spatial and temporal resolution of techniques like laser Doppler flowmetry and magnetic resonance imaging (MRI). The combination of laser speckle flowmetry (LSF) and multispectral reflectance imaging (MSRI) yields high-resolution spatiotemporal maps of hemodynamic and metabolic changes in response to functional cortical activation. During acute focal cerebral ischemia, changes in HbO and HbR are much larger than in functional activation, resulting in the failure of the Beer-Lambert approximation to yield accurate results. We describe the use of simultaneous LSF and MSRI, using a nonlinear Monte Carlo fitting technique, to record rapid changes in CBF, HbO, HbR, and cerebral metabolic rate of oxygen (CMRO2) during acute focal cerebral ischemia induced by distal middle cerebral artery occlusion (dMCAO) and reperfusion. This technique captures CBF and CMRO2 changes during hemodynamic and metabolic events with high temporal and spatial resolution through the intact skull and demonstrates the utility of simultaneous LSF and MSRI in mouse models of cerebrovascular disease. PMID:19021335
NASA Astrophysics Data System (ADS)
Strömberg, Tomas; Karlsson, Hanna; Fredriksson, Ingemar; Nyström, Fredrik H.; Larsson, Marcus
2014-05-01
Microvascular assessment would benefit from co-registration of blood flow and hemoglobin oxygenation dynamics during stimulus response tests. We used a fiber-optic probe for simultaneous recording of white light diffuse reflectance (DRS; 475-850 nm) and laser Doppler flowmetry (LDF; 780 nm) spectra at two source-detector distances (0.4 and 1.2 mm). An inverse Monte Carlo algorithm, based on a multiparameter three-layer adaptive skin model, was used for analyzing DRS data. LDF spectra were conventionally processed for perfusion. The system was evaluated on volar forearm recordings of 33 healthy subjects during a 5-min systolic occlusion protocol. The calibration scheme and the optimal adaptive skin model fitted DRS spectra at both distances within 10%. During occlusion, perfusion decreased within 5 s while oxygenation decreased slowly (mean time constant 61 s dissociation of oxygen from hemoglobin). After occlusion release, perfusion and oxygenation increased within 3 s (inflow of oxygenized blood). The increased perfusion was due to increased blood tissue fraction and speed. The supranormal hemoglobin oxygenation indicates a blood flow in excess of metabolic demands. In conclusion, by integrating DRS and LDF in a fiber-optic probe, a powerful tool for assessment of blood flow and oxygenation in the same microvascular bed has been presented.
Pierie, J P; De Graaf, P W; Poen, H; Van der Tweel, I; Obertop, H
1994-11-01
To assess the value of relative blood perfusion of the gastric tube in prediction of impaired healing of cervical oesophagogastrostomies. Prospective study. University hospital, The Netherlands. Thirty patients undergoing transhiatal oesophagectomy and partial gastrectomy for cancer of the oesophagus or oesophagogastric junction, with gastric tube reconstruction and cervical oesophagogastrostomy. Operative measurement of gastric blood perfusion at four sites by laser Doppler flowmetry and perfusion of the same sites after construction of the gastric tube expressed as a percentage of preconstruction values. The relative perfusion at the most proximal site of the gastric tube was significantly lower than at the more distal sites (p = 0.001). Nine of 18 patients (50%) in whom the perfusion of the proximal gastric tube was less than 70% of preconstruction values developed an anastomotic stricture, compared with only 1 of 12 patients (8%) with a relative perfusion of 70% or more (p = 0.024). A reduction in perfusion of the gastric tube did not predict leakage. Impaired anastomotic healing is unlikely if relative perfusion is 70% or more of preconstruction values. Perfusion of less than 70% partly predicts the occurrence of anastomotic stricture, but leakage cannot be predicted. Factors other than blood perfusion may have a role in the process of anastomotic healing.
Fredriksson, Ingemar; Burdakov, Oleg; Larsson, Marcus; Strömberg, Tomas
2013-12-01
The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.
NASA Astrophysics Data System (ADS)
Fredriksson, Ingemar; Burdakov, Oleg; Larsson, Marcus; Strömberg, Tomas
2013-12-01
The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.
Strömberg, Tomas; Karlsson, Hanna; Fredriksson, Ingemar; Nyström, Fredrik H; Larsson, Marcus
2014-05-01
Microvascular assessment would benefit from co-registration of blood flow and hemoglobin oxygenation dynamics during stimulus response tests. We used a fiber-optic probe for simultaneous recording of white light diffuse reflectance (DRS; 475-850 nm) and laser Doppler flowmetry (LDF; 780 nm) spectra at two source-detector distances (0.4 and 1.2 mm). An inverse Monte Carlo algorithm, based on a multiparameter three-layer adaptive skin model, was used for analyzing DRS data. LDF spectra were conventionally processed for perfusion. The system was evaluated on volar forearm recordings of 33 healthy subjects during a 5-min systolic occlusion protocol. The calibration scheme and the optimal adaptive skin model fitted DRS spectra at both distances within 10%. During occlusion, perfusion decreased within 5 s while oxygenation decreased slowly (mean time constant 61 s; dissociation of oxygen from hemoglobin). After occlusion release, perfusion and oxygenation increased within 3 s (inflow of oxygenized blood). The increased perfusion was due to increased blood tissue fraction and speed. The supranormal hemoglobin oxygenation indicates a blood flow in excess of metabolic demands. In conclusion, by integrating DRS and LDF in a fiber-optic probe, a powerful tool for assessment of blood flow and oxygenation in the same microvascular bed has been presented.
Abay, T Y; Kyriacou, P A
2016-04-01
Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p < 0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.
NASA Astrophysics Data System (ADS)
Humeau-Heurtier, Anne; Mahé, Guillaume; Chapeau-Blondeau, François; Rousseau, David; Abraham, Pierre
2012-07-01
Time irreversibility can be qualitatively defined as the degree of a signal for temporal asymmetry. Recently, a time irreversibility characterization method based on entropies of positive and negative increments has been proposed for experimental signals and applied to heart rate variability (HRV) data (central cardiovascular system (CVS)). The results led to interesting information as a time asymmetry index was found different for young subjects and elderly people or heart disease patients. Nevertheless, similar analyses have not yet been conducted on laser Doppler flowmetry (LDF) signals (peripheral CVS). We first propose to further investigate the above-mentioned characterization method. Then, LDF signals, LDF signals reduced to samples acquired during ECG R peaks (LDF_RECG signals) and HRV recorded simultaneously in healthy subjects are processed. Entropies of positive and negative increments for LDF signals show a nonmonotonic pattern: oscillations—more or less pronounced, depending on subjects—are found with a period matching the one of cardiac activity. However, such oscillations are not found with LDF_RECG nor with HRV. Moreover, the asymmetry index for LDF is markedly different from the ones of LDF_RECG and HRV. The cardiac activity may therefore play a dominant role in the time irreversibility properties of LDF signals.
Kaska, Milan; Blazej, Slavomir; Turek, Zdenek; Ryska, Ales; Jegorov, Boris; Radochova, Vera; Bezouska, Jan; Paral, Jiri
2018-01-01
The optimal surgical approach to reconnecting bowel ends safely after resection is of great importance. This project is focused on assessment of the perianastomotic microcirculation quality in the short postoperative period when using three different anastomosis techniques in experimental animal. The experimental study involved 27 young female domestic pigs divided into three subgroups of 9 animals according to each surgical method of anastomosis construction in the sigmoid colon region: by manual suture, by stapler, or by gluing. Blood microcirculation in the anastomosis region was monitored using Laser Doppler Flowmetry (LDF). Anastomosis healing was evaluated by macroscopic and histological examination. Evaluation of the microcirculation in the anastomosis region showed the smallest decrease in perfusion values in animals reconstructed by suturing (Δ= -38.01%). A significantly more profound drop was observed postoperatively after stapling or gluing (Δ= -52.42% and Δ= -59.53%, respectively). All performed anastomoses healed without any signs of tissue and function pathology. Sewing, stapling, and gluing techniques for bowel anastomosis each have a different effect on regional microcirculation during 120 min. postoperatively. Nevertheless, the final results of anastomosis healing were found without of any pathology in all experimental animals managed by above mentioned anastomotic techniques.
[Microcirculatory blood and lymph flow examination in eyelid skin by laser Doppler flowmetry].
Safonova, T N; Kintyukhina, N P; Sidorov, V V; Gladkova, O V; Reyn, E S
to study normal blood and lymph microcirculation of the upper and lower eyelids in different age groups. The study included 108 volunteers (216 eyes) aged from 20 to 80 years with no signs of changes in anterior segment structures, who were grouped by age ranges (20-30 years, 31-40 years, 41-50 years, 51-60 years, 61-70 years, and 71-80 years) into 6 groups equal in gender and quantitative composition. In all volunteers, microcirculation of the upper and lower eyelids was examined by laser Doppler flowmetry (LDF) ('LASMA MC-1' peripheral blood and lymph flow analyzer and 'LASMA MC' laser diagnostic complex, LASMA LLC). The average perfusion changes in blood and lymph flow as well as blood and lymph flow oscillations were analyzed. Blood and lymph flow in the microvasculature of the upper and lower eyelids is variable and depends on neither the age, nor gender of the test subject. On LDF-gram, every increase in amplitude of blood flow corresponds to a decrease in that of lymph flow. The non-invasive method of LDF expands our diagnostic capabilities as it enables assessment of not only blood, but also lymph flow. The data obtained can serve as a starting point for exploring microcirculation in different age groups in the presence of different pathological processes.
NASA Astrophysics Data System (ADS)
Humeau, Anne; Koitka, Audrey; Abraham, Pierre; Saumet, Jean-Louis; L'Huillier, Jean-Pierre
2004-09-01
In the biomedical field, the laser Doppler flowmetry (LDF) technique is a non-invasive method to monitor skin perfusion. On the skin of healthy humans, LDF signals present a significant transient increase in response to a local and progressive pressure application. This vasodilatory reflex response may have important implications for cutaneous pathologies involved in various neurological diseases and in the pathophysiology of decubitus ulcers. The present work analyses the dynamic characteristics of these signals on young type 1 diabetic patients, and on healthy age-matched subjects. To obtain accurate dynamic characteristic values, a de-noising wavelet-based algorithm is first applied to LDF signals. All the de-noised signals are then normalised to the same value. The blood flow peak and the time to reach this peak are then calculated on each computed signal. The results show that a large vasodilation is present on signals of healthy subjects. The mean peak occurs at a pressure of 3.2 kPa approximately. However, a vasodilation of limited amplitude appears on type 1 diabetic patients. The maximum value is visualised, on the average, when the pressure is 1.1 kPa. The inability for diabetic patients to increase largely their cutaneous blood flow may bring explanations to foot ulcers.
Yu, Sebastian; Hu, Stephen Chu-Sung; Yu, Hsin-Su; Chin, Yi-Ying; Cheng, Yang-Chun; Lee, Chih-Hung
2018-06-05
Skin physiology measurement is receiving more attention for detecting vasculopathy in systemic sclerosis (SSc). Laser Doppler flowmetry (LDF) is a widely used physiological measurement to assess cutaneous microcirculation. However, findings of LDF may be normal during early stage of microangiopathy in SSc. We hypothesized that cold stress test combined with LDF could detect early-stage microangiopathy in patients with SSc. A 67-year-old male came with multiple ulcerations on his fingers for one year. After excluding diseases such as diabetes mellitus-related peripheral arterial occlusive disease and smoking-related Buerger's disease, the diagnosis of SSc was made according to the 2013 ACR/EULAR criteria. We performed LDF and angiography for a patient with SSc and compared the results. Although occlusions of right ulnar and digital arteries were obvious in angiography, the baseline skin temperature and perfusion unit on right fingers remained within normal limits. While the microcirculatory abnormalities measured by LDF alone are subtle, LDF combined with cold stress test detected a significant slow recovery of skin blood flow 40 minutes after cold immersion. In conclusion, there may be discordance between macrovasculopathy and baseline microcirculatory blood flow in SSc. In such a case, cold immersion test is essential to measure the dynamic change and slow recovery of blood flow.
Reproducibility and sensitivity of scanning laser Doppler flowmetry during graded changes in PO2
Strenn, K.; Menapace, R.; Rainer, G.; Findl, O.; Wolzt, M.; Schmetterer, L.
1997-01-01
AIMS/BACKGROUND—Recently a commercially available scanning laser Doppler flowmeter has been produced, which provides two dimensional maps of the retinal perfusion. The aim of the present study was to investigate the reproducibility and the sensitivity of these measurements. METHODS—16 healthy subjects were randomised to inhale different gas mixtures of oxygen and nitrogen in a double blind crossover study. The following gas mixtures of oxygen and nitrogen were administered: 100% oxygen + 0% nitrogen, 80% oxygen + 20% nitrogen, 60% oxygen + 40% nitrogen, 40% oxygen + 60% nitrogen, 30% oxygen + 70% nitrogen, 20% oxygen + 80% nitrogen, 15% oxygen + 85% nitrogen, and 10% oxygen + 90% nitrogen. Retinal haemodynamic variables and systemic haemodynamics were measured during all inhalation periods. Recordings under resting conditions were performed three times to calculate intraclass coefficients. RESULTS—In two subjects we did not obtain technically adequate results. A dose dependent change in retinal blood flow during graded oxygen breathing was observed (p < 0.001). During 100% oxygen breathing blood flow decrease was between 29% and 33%, whereas blood flow increase was between 28% and 33% during inhalation of 10% oxygen + 90% nitrogen. CONCLUSIONS—Scanning laser Doppler flowmetry has an acceptable reproducibility and is appropriate for description of the effect of graded changes in PO2 on retinal haemodynamics. The main problems with the system are the large zero offset, the fixation during retinal scanning, and the neglect of blood flow changes during the cardiac cycle. PMID:9227199
Coulon, P; Constans, J; Gosse, P
2012-01-01
We lack non-invasive tools for evaluating the coronary and renal microcirculations. Since cutaneous Doppler laser exploration has evidenced impaired cutaneous microvascular responses in coronary artery disease and in impaired renal function, we wanted to find out if there was a link between the impairments in the cutaneous and renal microcirculations. To specify the significance of the rise in the renal resistive index (RI), which is still unclear, we also sought relations between RI and arterial stiffness. We conducted a cross-sectional controlled study in a heterogeneous population including hypertensive patients of various ages with or without a history of cardiovascular disease along with a healthy control group. The cutaneous microcirculation was evaluated by laser Doppler flowmetry of the post-occlusive reactive hyperhemy (PORH) and of the hyperhemy to heat. The renal microcirculation was evaluated by measurement of the RI. Arterial stiffness was evaluated from an ambulatory measurement of the corrected QKD(100-60) interval. We included 22 hypertensives and 11 controls of mean age 60.6 vs 40.8 years. In this population, there was a correlation between RI and basal zero to peak flow variation (BZ-PF) (r=-0.42; P=0.02) and a correlation between RI and rest flow to peak flow variation (RF-PF) (r=-0.44; P=0.01). There was also a significant correlation between RI and the corrected QKD(100-60) (r=-0.47; P=0.01). The significant correlation between PORH parameters and RI indicates that the functional modifications of the renal and cutaneous microcirculations tend to evolve in parallel during ageing or hypertension. The relation between RI and arterial stiffness shows that RI is a compound index of both renal microvascular impairment and the deterioration of macrovascular mechanics.
Lee, Bernard; Benyajati, Siribhinya; Woods, Jeffrey A; Jan, Yih-Kuen
2014-05-01
The primary purpose of this feasibility study was to establish a correlation between pro-inflammatory cytokine accumulation and severity of tissue damage during local pressure with various temperatures. The secondary purpose was to compare skin blood flow patterns for assessing the efficacy of local cooling on reducing skin ischemia under surface pressure. Eight Sprague-Dawley rats were assigned to two protocols, including pressure with local cooling (Δt = -10 °C) and pressure with local heating (Δt = 10 °C). Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin perfusion quantified by laser Doppler flowmetry and TNF-∗ and IL-1β levels were measured. Our results showed that TNF-α concentrations were increased more significantly with local heating than with local cooling under pressure whereas IL-1β did not change. Our results support the notion that weight bearing soft tissue damage may be reduced through temperature modulation and that non-invasive perfusion measurements using laser Doppler flowmetry may be capable of assessing viability. Furthermore, these results show that perfusion response to loading pressure may be correlated with changes in local pro-inflammatory cytokines. These relationships may be relevant for the development of cooling technologies for reducing risk of pressure ulcers. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Mizeva, Irina; Di Maria, Costanzo; Frick, Peter; Podtaev, Sergey; Allen, John
2015-03-01
Photoplethysmography (PPG) and laser Doppler flowmetry (LDF) are two recognized optical techniques that can track low-frequency perfusion changes in microcirculation. The aim of this study was to determine, in healthy subjects, the correlation between the techniques for specific low-frequency bands previously defined for microcirculation. Twelve healthy male subjects (age range 18 to 50 years) were studied, with PPG and LDF signals recorded for 20 min from their right and left index (PPG) and middle (LDF) fingers. Wavelet analysis comprised dividing the low-frequency integral wavelet spectrum (IWS) into five established physiological bands relating to cardiac, respiratory, myogenic, neurogenic, and endothelial activities. The correlation between PPG and LDF was quantified using wavelet correlation analysis and Spearman correlation analysis of the median IWS amplitude. The median wavelet correlation between signals (right-left side average) was 0.45 (cardiac), 0.49 (respiratory), 0.86 (myogenic), 0.91 (neurogenic), and 0.91 (endothelial). The correlation of IWS amplitude values (right-left side average) was statistically significant for the cardiac (ρ=0.64, p<0.05) and endothelial (ρ=0.62, p<0.05) bands. This pilot study has shown good correlation between PPG and LDF for specific physiological frequency bands. In particular, the results suggest that PPG has the potential to be a low-cost replacement for LDF for endothelial activity assessments.
Binzoni, T; Leung, T S; Rüfenacht, D; Delpy, D T
2006-01-21
Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware.
Bernjak, A; Deitrick, G A; Bauman, W A; Stefanovska, A; Tuckman, J
2011-05-01
The 1984/86 published neurogram results showing only rare sympathetic nerve activity (SNA) to the muscles and skin in tetraplegia are still accepted. The present study by a different method attempted to confirm or deny those findings. The effect of basal SNA to the microcirculation of the feet and calf in 10 complete (AIS A) traumatic tetraplegic and 10 healthy age matched subjects were evaluated by wavelet transform of laser Doppler flowmetry (LDF) recordings. The results clearly indicated there is significant basal SNA from the decentralized spinal cord in tetraplegia. In addition, wavelet analysis allowed a study of other influences on the microcirculation besides SNA. Collectively, in tetraplegia compared with controls, the powers of the low frequency oscillations in blood flow were reduced; in that the endothelium caused less vasodilatation while the SNA and intrinsic vascular smooth muscles induced smaller degrees of vasoconstriction. However, the high frequency and especially the cardiac powers were greater. The latter presenting an obvious important factor for the preservation of blood flow in the microcirculation. It is suggested that basal SNA to the cutaneous microcirculation occurs in complete tetraplegia, and the significant levels of circulating noradrenaline reported by others indicate this is also true in other parts of the body. This may explain the usual absence of severe, incapacitating, autonomic deficiency in this condition. Published by Elsevier Inc.
Ultrasonically Encoded Photoacoustic Flowgraphy in Biological Tissue
NASA Astrophysics Data System (ADS)
Wang, Lidai; Xia, Jun; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2013-11-01
Blood flow speed is an important functional parameter. Doppler ultrasound flowmetry lacks sufficient sensitivity to slow blood flow (several to tens of millimeters per second) in deep tissue. To address this challenge, we developed ultrasonically encoded photoacoustic flowgraphy combining ultrasonic thermal tagging with photoacoustic imaging. Focused ultrasound generates a confined heat source in acoustically absorptive fluid. Thermal waves propagate with the flow and are directly visualized in pseudo color using photoacoustic computed tomography. The Doppler shift is employed to calculate the flow speed. This method requires only acoustic and optical absorption, and thus is applicable to continuous fluid. A blood flow speed as low as 0.24mm·s-1 was successfully measured. Deep blood flow imaging was experimentally demonstrated under 5-mm-thick chicken breast tissue.
A new laser Doppler flowmeter prototype for depth dependent monitoring of skin microcirculation
NASA Astrophysics Data System (ADS)
Figueiras, E.; Campos, R.; Semedo, S.; Oliveira, R.; Requicha Ferreira, L. F.; Humeau-Heurtier, A.
2012-03-01
Laser Doppler flowmetry (LDF) is now commonly used in clinical research to monitor microvascular blood flow. However, the dependence of the LDF signal on the microvascular architecture is still unknown. That is why we propose a new laser Doppler flowmeter for depth dependent monitoring of skin microvascular perfusion. This new laser Doppler flowmeter combines for the first time, in a device, several wavelengths and different spaced detection optical fibres. The calibration of the new apparatus is herein presented together with in vivo validation. Two in vivo validation tests are performed. In the first test, signals collected in the ventral side of the forearm are analyzed; in the second test, signals collected in the ventral side of the forearm are compared with signals collected in the hand palm. There are good indicators that show that different wavelengths and fibre distances probe different skin perfusion layers. However, multiple scattering may affect the results, namely the ones obtained with the larger fibre distance. To clearly understand the wavelength effect in LDF measurements, other tests have to be performed.
[Urodynamics foundations: contractile potency and urethral doppler].
Benítez Navío, Julio; Caballero Gómez, Pilar; Delgado Elipe, Ildefonso
2002-12-01
To calculate the bladder softening factor, elastic constant and contractile potency. For the analysis we considered bladder behavior like that of a spring. See articles 1 and 2 published in this issue. Using flowmetry, Doppler ultrasound and abdominal pressure (Transrectal pressure register catheter) an analytical solution that permits calculation of factors defining bladder behavior was looked for. Doppler ultrasound allows us to know urine velocity through the prostatic urethra and, therefore, to calculate bladder contractile potency. Equations are solved reaching an analytical solution that allows calculating those factors that define bladder behavior: Bladder contractile potency, detrusor elastic constant, considering it behaves like a spring, and calculation of muscle resistance to movement. All thanks to Doppler ultrasound that allows to know urine speed. The bladder voiding phase is defined with the aforementioned factors; storage phase behavior can be indirectly inferred. Only uroflowmetry curves, Doppler ultrasound and abdominal pressure value are used. We comply with the so called non invasive urodynamics although for us it is just another phase in the biomechanical study of the detrusor muscle. Main conclusion is the addition of Doppler ultrasound to the urodynamist armamentarium as an essential instrument for the comprehension of bladder dynamics and calculation of bladder behavior defining factors. It is not a change in the focus but in the methods, gaining knowledge and diminishing invasion.
Sharif, S.A.; Taydas, E.; Mazhar, A.; Rahimian, R.; Kelly, K.M.; Choi, B.; Durkin, A.J.
2012-01-01
Port wine stain (PWS) birthmarks are one class of benign congenital vascular malformation. Laser therapy is the most successful treatment modality of PWS. Unfortunately, this approach has limited efficacy, with only 10% of patients experiencing complete blanching of the PWS. To address this problem, several research groups have developed technologies and methods designed to study treatment outcome and improve treatment efficacy. This paper reviews seven optical imaging techniques currently in use or under development to assess treatment efficacy, focusing on: Reflectance spectrophotometers/tristimulus colorimeters, Laser Doppler flowmetry (LDF) and Laser Doppler imaging (LDI), Cross-polarized diffuse reflectance color imaging system (CDR), Reflectance Confocal Microscopy (RCM), Optical Coherence Tomography (OCT), Spatial Frequency Domain Imaging (SFDI), and Laser Speckle Imaging (LSI). PMID:22804872
Monnet, Eric; Pelsue, Davyd; MacPhail, Catriona
2006-02-01
To validate laser doppler flowmetry (LDF) for measurement of blood flow in the stomach wall of dogs with gastric dilatation-volvulus (GDV). Six purpose-bred dogs and 24 dogs with naturally occurring GDV. Experimental and clinical. Capillary blood flow in the body of the stomach and pyloric antrum was measured with LDF (tissue perfusion unit (TPU) before and after induction of portal hypertension (PH) and after PH plus gastric ischemia (GI; PH + GI) and compared with flow measured by colored microsphere technique. Capillary flow was measured by LDF in the stomach wall of dogs with GDV. PH and PH+GI induced a significant reduction in blood flow in the body of the stomach (P = .019). A significant positive correlation was present between percent changes in capillary blood flow measured by LDF and colored microspheres after induction of PH + GI in the body of the stomach (r = 0.94, P = .014) and in the pyloric antrum (r = 0.95, P = .049). Capillary blood flow measured in the body of the stomach of 6 dogs that required partial gastrectomy (5.00+/-3.30 TPU) was significantly lower than in dogs that did not (28.00+/-14.40 TPU, P = .013). LDF can detect variations in blood flow in the stomach wall of dogs. LDF may have application for evaluation of stomach wall viability during surgery in dogs with GDV.
Ultrasound in differential diagnosis of periapical radiolucencies: A radiohistopathological study
Khambete, Neha; Kumar, Rahul
2015-01-01
Objectives: To evaluate the efficacy of ultrasound in differential diagnosis of periapical radiolucencies. Materials and Methods: Ten patients aged between 19 years and 40 years with periapical lesions associated with anterior maxillary or mandibular teeth were selected and consented for the study. Pre-operative periapical radiographs were obtained. Measurements and provisional diagnoses of the apical areas were made by two specialist observers on two separate occasions. Preoperative ultrasound examinations with Doppler flowmetry were then performed and the images assessed by two specialist observers for the size, contents, vascular supply and a provisional diagnosis made as to whether the lesion was a cyst or granuloma. Endodontic surgery was performed including curettage of the apical tissues to enable histopathological investigation, which provided the gold standard diagnosis. All measurements and findings were compared and statistically analyzed. Results: Total 10 lesions were identified in 10 patients. On periapical radiographs, lesions were readily identified but observers were unable to differentiate granuloma from cyst using either modality. Where sufficient buccal cortical bone had been resorbed, ultrasound imaging was simple but underestimated the size of the lesions compared with periapical radiographs. In all cases, the ultrasound diagnosis agreed with the histopathological gold standard. Conclusion: Ultrasonography (USG) can provide accurate information about the nature of intraosseous lesions of the jaws before any surgical procedure. It is proposed that USG with Doppler flowmetry can provide an additional diagnostic tool without invasive surgery, where treatment option is nonsurgical. PMID:25657525
The blood perfusion and NADH/FAD content combined analysis in patients with diabetes foot
NASA Astrophysics Data System (ADS)
Dremin, Victor V.; Sidorov, Victor V.; Krupatkin, Alexander I.; Galstyan, Gagik R.; Novikova, Irina N.; Zherebtsova, Angelina I.; Zherebtsov, Evgeny A.; Dunaev, Andrey V.; Abdulvapova, Zera N.; Litvinova, Karina S.; Rafailov, Ilya E.; Sokolovski, Sergei G.; Rafailov, Edik U.
2016-03-01
Skin blood microcirculation and the metabolism activity of tissue were examined on the patients with type 2 diabetes. Laser Doppler flowmetry (LDF) with 1064 nm laser light source and fluorescence spectroscopy (FS) with excitation light of 365 nm and 450 nm have been used to monitor the blood perfusion and the content of coenzymes NADH and FAD. Concluding, the proposed combined LDF and tissue FS approach allows to identify the significant violations in the blood microcirculation and metabolic activity for type 2 diabetes patients.
[Temperature-dependent changes in the microcirculation of the dental pulp].
Raab, W H; Müller, H
1989-07-01
Laser Doppler flowmetry was used to study the changes in the blood flow within the dental pulp as a reaction to thermal stimuli between 17 degrees C and 57 degree C. Temperatures below 31 degrees C resulted in a reduction, temperatures above 43 degrees C in an increase in blood flow. Temperatures higher than 49 degrees C caused irreversible damage to the pulp's microcirculation. Experimental nerve blocks showed that the reactive increase is linked to the afferent rather than the sympathetic innervation of the tooth pulp.
Kul'chitskaia, D B
2009-01-01
The study with the use of laser Doppler flowmetry has revealed pathological changes in the microcirculatory system of patients with arterial hypertension. Their treatment with a low-frequency magnetic field showed that its effect on microcirculation depends on the regime and site of application of magnetotherapy as well as its combination with other physical factors. Frontal application of the magnetic field had the most pronounced beneficial effect on dynamic characteristics of microcirculation. Pulsed regime of magnetotherapy was more efficacious than conventional one. Amplipulse magnetotherapy produced better results than monotherapy.
Processing methods for photoacoustic Doppler flowmetry with a clinical ultrasound scanner
NASA Astrophysics Data System (ADS)
Bücking, Thore M.; van den Berg, Pim J.; Balabani, Stavroula; Steenbergen, Wiendelt; Beard, Paul C.; Brunker, Joanna
2018-02-01
Photoacoustic flowmetry (PAF) based on time-domain cross correlation of photoacoustic signals is a promising technique for deep tissue measurement of blood flow velocity. Signal processing has previously been developed for single element transducers. Here, the processing methods for acoustic resolution PAF using a clinical ultrasound transducer array are developed and validated using a 64-element transducer array with a -6 dB detection band of 11 to 17 MHz. Measurements were performed on a flow phantom consisting of a tube (580 μm inner diameter) perfused with human blood flowing at physiological speeds ranging from 3 to 25 mm / s. The processing pipeline comprised: image reconstruction, filtering, displacement detection, and masking. High-pass filtering and background subtraction were found to be key preprocessing steps to enable accurate flow velocity estimates, which were calculated using a cross-correlation based method. In addition, the regions of interest in the calculated velocity maps were defined using a masking approach based on the amplitude of the cross-correlation functions. These developments enabled blood flow measurements using a transducer array, bringing PAF one step closer to clinical applicability.
Kövamees, Oskar; Shemyakin, Alexey; Checa, Antonio; Wheelock, Craig E; Lundberg, Jon O; Östenson, Claes-Göran; Pernow, John
2016-11-01
The development of microvascular complications in diabetes is a complex process in which endothelial dysfunction is important. Emerging evidence suggests that arginase is a key mediator of endothelial dysfunction in type 2 diabetes mellitus by reciprocally regulating nitric oxide bioavailability. The aim of this prospective intervention study was to test the hypothesis that arginase activity is increased and that arginase inhibition improves microvascular endothelial function in patients with type 2 diabetes and microvascular dysfunction. Microvascular endothelium-dependent and -independent dilatation was determined in patients with type 2 diabetes (n = 12) and healthy age-matched control subjects (n = 12) with laser Doppler flowmetry during iontophoretic application of acetylcholine and sodium nitroprusside, respectively, before and after administration of the arginase inhibitor N ω -hydroxy-nor-L-arginine (120 min). Plasma ratios of amino acids involved in arginase and nitric oxide synthase activities were determined. The laser Doppler flowmetry data were the primary outcome variable. Microvascular endothelium-dependent dilatation was impaired in subjects with type 2 diabetes (P < .05). After administration of N ω -hydroxy-nor-L-arginine, microvascular endothelial function improved significantly in patients with type 2 diabetes to the level observed in healthy controls. Endothelium-independent vasodilatation did not change significantly. Subjects with type 2 diabetes had higher levels of ornithine and higher ratios of ornithine/citrulline and ornithine/arginine (P < .05), suggesting increased arginase activity. Arginase inhibition improves microvascular endothelial function in patients with type 2 diabetes and microvascular dysfunction. Arginase inhibition may represent a novel therapeutic strategy to improve microvascular endothelial function in patients with type 2 diabetes.
NASA Astrophysics Data System (ADS)
Li, Yung-Hui; Hu, Chia-Ming; Tsai, Ming-Lun
2017-10-01
Laser Doppler Flowmetry (LDF), a non-invasive microcirculation measurement equipment, is designed to be used in measuring microcirculation and perfusion in the skin. LDF is very applicable to healthcare. However, the cost of commercial LDF prevents its prevalence and popularity. In this paper, continuing previous researches, a LDF prototype was built from the combination of the off-the-shelf electronic components. The raw signals acquired from the proposed LDF prototype is validated to be relevant to the microcirculation flux. Furthermore, we would like to verify the consistency between the signals measured from both model, and find an implicit transformation rule to transform the LDF prototype signals. For the purpose of verification and calibration of the LDF prototype signal feature, we first collected a parallel database consisting of flux signals measured by commercial and prototype LDF at the same time. Second, we extract signals with specific frequency of normalized signals as features and use these features to establish a model to allow us to map signals measured by LDF prototype to the commercial model. The result of the experiment showed that after we used the linear regression models to calibrate physiological feature, the correlation coefficient reached nearly 0.9999, which is close to a perfect positive correlation. The overall evaluation results showed that the proposed method can verify and ensure the validity of the LDF prototype. Through the proposed transformation, the flux signals measured by the proposed LDF prototype can successfully be transformed to its parallel form as if it is measured by commercial LDF.
Altered skin flowmotion in hypertensive humans
Bruning, R.S.; Kenney, W.L.; Alexander, L.M.
2017-01-01
Essential hypertensive humans exhibit attenuated cutaneous nitric oxide (NO)-dependent vasodilation. Using spectral analysis (fast Fourier transformation) we aimed to characterize the skin flowmotion contained in the laser-Doppler flowmetry recordings during local heating-induced vasodilation before and after concurrent pharmacological inhibition of nitric oxide synthase (NOS) in hypertensive and age-matched normotensive men and women. We hypothesized that hypertensive subjects would have lower total power spectral densities (PSD), specifically in the frequency intervals associated with intrinsic endothelial and neurogenic control of the microvasculature. Furthermore, we hypothesized that NOS inhibition would attenuate the endothelial frequency interval. Laser-Doppler flowmetry recordings during local heating experiments from 18 hypertensive (MAP: 108±2mmHg) and 18 normotensive (MAP: 88±2mmHg) men and women were analyzed. Within site NO-dependent vasodilation was assessed by perfusion of a non-specific NOS inhibitor (NG-nitro-L-arginine methyl ester; L-NAME) through intradermal microdialysis during the heating-induced plateau in skin blood flow. Local heating-induced vasodilation increased total PSD for all frequency intervals (all p<0.001). Hypertensives had a lower total PSD (p=0.03) and absolute neurogenic frequency intervals (p<0.01) compared to the normotensives. When normalized as a percentage of total PSD, hypertensives had reduced neurogenic (p<0.001) and augmented myogenic contributions (p=0.04) to the total spectrum. NOS inhibition decreased total PSD (p<0.001) for both groups, but hypertensives exhibited lower absolute endothelial (p<0.01), neurogenic (p<0.05), and total PSD (p<0.001) frequency intervals compared to normotensives. These data suggest that essential hypertension results in altered neurogenic and NOS-dependent control of skin flowmotion and support the use of spectral analysis as a non-invasive technique to study vasoreactivity. PMID:24418051
Fredriksson, Ingemar; Larsson, Marcus; Nyström, Fredrik H.; Länne, Toste; Östgren, Carl J.; Strömberg, Tomas
2010-01-01
OBJECTIVE To compare the microcirculatory velocity distribution in type 2 diabetic patients and nondiabetic control subjects at baseline and after local heating. RESEARCH DESIGN AND METHODS The skin blood flow response to local heating (44°C for 20 min) was assessed in 28 diabetic patients and 29 control subjects using a new velocity-resolved quantitative laser Doppler flowmetry technique (qLDF). The qLDF estimates erythrocyte (RBC) perfusion (velocity × concentration), in a physiologically relevant unit (grams RBC per 100 g tissue × millimeters per second) in a fixed output volume, separated into three velocity regions: v <1 mm/s, v 1–10 mm/s, and v >10 mm/s. RESULTS The increased blood flow occurs in vessels with a velocity >1 mm/s. A significantly lower response in qLDF total perfusion was found in diabetic patients than in control subjects after heat provocation because of less high-velocity blood flow (v >10 mm/s). The RBC concentration in diabetic patients increased sevenfold for v between 1 and 10 mm/s, and 15-fold for v >10 mm/s, whereas no significant increase was found for v <1 mm/s. The mean velocity increased from 0.94 to 7.3 mm/s in diabetic patients and from 0.83 to 9.7 mm/s in control subjects. CONCLUSIONS The perfusion increase occurs in larger shunting vessels and not as an increase in capillary flow. Baseline diabetic patient data indicated a redistribution of flow to higher velocity regions, associated with longer duration of diabetes. A lower perfusion was associated with a higher BMI and a lower toe-to-brachial systolic blood pressure ratio. PMID:20393143
Treu, Curt; de Souza, Maria das Graças Coelho; Lupi, Omar; Sicuro, Fernando Lencastre; Maranhão, Priscila Alves; Kraemer-Aguiar, Luiz Guilherme; Bouskela, Eliete
2017-01-01
Leprosy is a chronic granulomatous infection of skin and peripheral nerves caused by Mycobacterium leprae and is considered the main infectious cause of disability worldwide. Despite the several studies regarding leprosy, little is known about its effects on microvascular structure and function in vivo. Thus, we have aimed to compare skin capillary structure and functional density, cutaneous vasomotion (spontaneous oscillations of arteriolar diameter), which ensures optimal blood flow distribution to skin capillaries) and cutaneous microvascular blood flow and reactivity between ten men with lepromatous leprosy (without any other comorbidity) and ten age- and gender-matched healthy controls. Orthogonal polarization spectral imaging was used to evaluate skin capillary morphology and functional density and laser Doppler flowmetry to evaluate blood flow, vasomotion and spectral analysis of flowmotion (oscillations of blood flow generated by vasomotion) and microvascular reactivity, in response to iontophoresis of acetylcholine and sodium nitroprusside. The contribution of different frequency components of flowmotion (endothelial, neurogenic, myogenic, respiratory and cardiac) was not statistically different between groups. However, endothelial-dependent and -independent vasodilatations elicited by acetylcholine and sodium nitroprusside iontophoresis, respectively, were significantly reduced in lepromatous leprosy patients compared to controls, characterizing the existence of microvascular dysfunction. These patients also presented a significant increase in the number of capillaries with morphological abnormalities and in the diameters of the dermal papilla and capillary bulk when compared to controls. Our results suggest that lepromatous leprosy causes severe microvascular dysfunction and significant alterations in capillary structure. These structural and functional changes are probably induced by exposure of the microvascular bed to chronic inflammation evoked by the Mycobacterium leprae. PMID:28419120
Vessel packaging effect in laser speckle contrast imaging and laser Doppler imaging.
Fredriksson, Ingemar; Larsson, Marcus
2017-10-01
Laser speckle-based techniques are frequently used to assess microcirculatory blood flow. Perfusion estimates are calculated either by analyzing the speckle fluctuations over time as in laser Doppler flowmetry (LDF), or by analyzing the speckle contrast as in laser speckle contrast imaging (LSCI). The perfusion estimates depend on the amount of blood and its speed distribution. However, the perfusion estimates are commonly given in arbitrary units as they are nonlinear and depend on the magnitude and the spatial distribution of the optical properties in the tissue under investigation. We describe how the spatial confinement of blood to vessels, called the vessel packaging effect, can be modeled in LDF and LSCI, which affect the Doppler power spectra and speckle contrast, and the underlying bio-optical mechanisms for these effects. As an example, the perfusion estimate is reduced by 25% for LDF and often more than 50% for LSCI when blood is located in vessels with an average diameter of 40 μm, instead of being homogeneously distributed within the tissue. This significant effect can be compensated for only with knowledge of the average diameter of the vessels in the tissue. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Microprobes For Blood Flow Measurements In Tissue And Small Vessels
NASA Astrophysics Data System (ADS)
Oberg, P. A.; Salerud, E. G.
1988-04-01
Laser Doppler flowmetry is a method for the continuous and non-invasive recording of tissue blood flow. The method has already proved to be advantageous in a number of clinical as well as theoretical medical disciplines. In dermatology, plastic- and gastrointestinal surgery laser Doppler measurements have substantially contributed to increase knowledge of microvascular perfusion. In experimental medicine, the method has been used in the study of a great variety of microvascular problems. Spontaneous rhythmical variations, spatial and temporal fluctuations in human skin blood flow are mentioned as examples of problem areas in which new knowledge has been generated. The method has facilitated further investigations of the nature of spongeous bone blood flow, testis and kidney cortex blood flow. Recently we have showed that a variant of the laser Doppler method principle, using a single optical fiber, can be advantageous in deep tissue measurements. With this method laser light is transmitted bidirectionally in a single fiber. The tissue trauma which affects blood flow can be minimized by introducing small diameter fibers (0.1-0.5 mm). A special set-up utilizing the same basic principle has been used for the recording of blood flow in small vessels.
Prediction of the First Variceal Haemorrhage
1997-01-01
We followed 87 cirrhotic patients with esophageal varices and without previous hemorrhage for a mean period of 24 mo to prospectively evaluate the occurance of variceal bleeding within (early) or after (late) 6 mo from entry and the contribution of portal Doppler ultrasound parameters to the prediction of early and late hemorrhage. Clinical, biochemical, endoscopic and portal Doppler ultrasound parameters were recorded at entry. Variceal bleeding occurred in 22 patients (25.3%). Nine (40.9%) bled within the first 6 mo. Cox regression analysis identified variceal size, cherry-red spots, serum bilirubin and congestion index of the portal vein (the ratio of portal vein [cross-sectional area] and portal blood flow velocity) as the only independent predictors of first variceal hemorrhage. Discriminant analysis was used to find the prognostic index cut off points to identify patients who bled within 6 mo (prognostic group 1) or after 6 mo (prognostic group 2) or remained free of bleeding (prognostic group 3). The cumulative proportion of patients correctly classified was 73% in prognostic group 1, 47% in prognostic group 2 and more than 80% in prognostic group 3. The addition of Doppler ultrasound flowmetry to clinical, biochemical and endoscopic parameter only improved the classification of patients with early bleeding. PMID:9184882
Grudzińska, Ewa; Modrzejewska, Monika
2018-01-01
Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.
Choo, Hui C; Nosaka, Kazunori; Peiffer, Jeremiah J; Ihsan, Mohammed; Yeo, Chow C; Abbiss, Chris R
2017-09-01
This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 ± 0.4°C and 32 ± 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (%CVC BL ). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, %CVC BL , TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r 2 = 0.062) and TOI (r 2 = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.
Lepilin, A V; Erokina, N L; Rogatina, T V; Khlusov, I Iu
2009-01-01
The objective of this study was to compare results of dynamic magnetotherapy (DMT), transdermal electroneurostimulation (TDENS), and traditional ultrahigh frequency (UHF) therapy in 473 patients with mandibular fractures and concomitant inflammatory diseases of paradontium. The parameters measured in the study included hygienic and paradontal indices, microcirculation patterns (using laser Doppler flowmetry), and the degree of mandibular fragment consolidation. It was shown that combined treatment with DMT and TDENS using an AMO-ATOS-E apparatus permits to eliminate clinical symptoms of paradontal inflammatory diseases twice as fast as traditional ultrahigh frequency therapy and ensures a two-fold reduction in the frequency of complications.
Effects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography.
Dziennis, Suzan; Reif, Roberto; Zhi, Zhongwei; Nuttall, Alfred L; Wang, Ruikang K
2012-10-01
Reduced cochlear blood flow (CoBF) is a main contributor to hearing loss. Studying CoBF has remained a challenge due to the lack of available tools. Doppler optical microangiography (DOMAG), a method to quantify single-vessel absolute blood flow, and laser Doppler flowmetry (LDF), a method for measuring the relative blood flow within a large volume of tissue, were used for determining the changes in CoBF due to systemic hypoxia in mice. DOMAG determined the change in blood flow in the apical turn (AT) with single-vessel resolution, while LDF averaged the change in the blood flow within a large volume of the cochlea (hemisphere with ∼1 to 1.5 mm radius). Hypoxia was induced by decreasing the concentration of oxygen-inspired gas, so that the oxygen saturation was reduced from >95% to ∼80%. DOMAG determined that during hypoxia the blood flow in two areas of the AT near and far from the helicotrema were increased and decreased, respectively. The LDF detected a decrease in blood flow within a larger volume of the cochlea (several turns averaged together). Therefore, the use of DOMAG as a tool for studying cochlear blood flow due to its ability to determine absolute flow values with single-vessel resolution was proposed.
Effects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography
NASA Astrophysics Data System (ADS)
Dziennis, Suzan; Reif, Roberto; Zhi, Zhongwei; Nuttall, Alfred L.; Wang, Ruikang K.
2012-10-01
Reduced cochlear blood flow (CoBF) is a main contributor to hearing loss. Studying CoBF has remained a challenge due to the lack of available tools. Doppler optical microangiography (DOMAG), a method to quantify single-vessel absolute blood flow, and laser Doppler flowmetry (LDF), a method for measuring the relative blood flow within a large volume of tissue, were used for determining the changes in CoBF due to systemic hypoxia in mice. DOMAG determined the change in blood flow in the apical turn (AT) with single-vessel resolution, while LDF averaged the change in the blood flow within a large volume of the cochlea (hemisphere with ˜1 to 1.5 mm radius). Hypoxia was induced by decreasing the concentration of oxygen-inspired gas, so that the oxygen saturation was reduced from >95% to ˜80%. DOMAG determined that during hypoxia the blood flow in two areas of the AT near and far from the helicotrema were increased and decreased, respectively. The LDF detected a decrease in blood flow within a larger volume of the cochlea (several turns averaged together). Therefore, the use of DOMAG as a tool for studying cochlear blood flow due to its ability to determine absolute flow values with single-vessel resolution was proposed.
Høyer, C; Paludan, J P D; Pavar, S; Biurrun Manresa, J A; Petersen, L J
2014-03-01
To assess the intra- and inter-observer variation in laser Doppler flowmetry curve reading for measurement of toe and ankle pressures. A prospective single blinded diagnostic accuracy study was conducted on 200 patients with known or suspected peripheral arterial disease (PAD), with a total of 760 curve sets produced. The first curve reading for this study was performed by laboratory technologists blinded to clinical clues and previous readings at least 3 months after the primary data sampling. The pressure curves were later reassessed following another period of at least 3 months. Observer agreement in diagnostic classification according to TASC-II criteria was quantified using Cohen's kappa. Reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis. The overall agreement in diagnostic classification (PAD/not PAD) was 173/200 (87%) for intra-observer (κ = .858) and 175/200 (88%) for inter-observer data (κ = .787). Reliability analysis confirmed excellent correlation for both intra- and inter-observer data (ICC all ≥.931). The coefficients of variance ranged from 2.27% to 6.44% for intra-observer and 2.39% to 8.42% for inter-observer data. Subgroup analysis showed lower observer-variation for reading of toe pressures in patients with diabetes and/or chronic kidney disease than patients not diagnosed with these conditions. Bland-Altman plots showed higher variation in toe pressure readings than ankle pressure readings. This study shows substantial intra- and inter-observer agreement in diagnostic classification and reading of absolute pressures when using laboratory technologists as observers. The study emphasises that observer variation for curve reading is an important factor concerning the overall reproducibility of the method. Our data suggest diabetes and chronic kidney disease have an influence on toe pressure reproducibility. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Non-invasive assessment of cerebral oxygen metabolism following surgery of congenital heart disease.
Neunhoeffer, Felix; Sandner, Katharina; Wiest, Milena; Haller, Christoph; Renk, Hanna; Kumpf, Matthias; Schlensak, Christian; Hofbeck, Michael
2017-07-01
Cerebral protection is a major issue in the treatment of infants with complex congenital heart disease. We tested a new device combining tissue spectrometry and laser Doppler flowmetry for non-invasive determination of cerebral oxygen metabolism following cardiac surgery in infants. We prospectively measured regional cerebral oxygen saturation cSO 2 and microperfusion (rcFlow) in 43 infants 12-24 h following corrective ( n = 30) or palliative surgery ( n = 13) of congenital heart defects. For comparison, cerebral blood flow (CBF) was determined by colour duplex sonography of the extracranial cerebral arteries. Cerebral fractional tissue oxygen extraction, approximated cerebral metabolic rate of oxygen (aCMRO 2 ) and cerebral metabolic rate of oxygen (CMRO 2 ) were calculated. cSO 2 was lower [54.6% (35.7-64.0) vs 59.7% (44.5-81.7); P < 0.01] after neonatal palliation, while rcFlow [69.7 AU (42.5-165.3) vs 77.0 AU (41.2-168.1); P = 0.06] and cerebral fractional tissue oxygen extraction [0.34 (0.24-0.82) vs 0.38 (0.17-0.55); P = 0.63] showed a trend towards lower values. We found a positive correlation between aCMRO 2 and CMRO 2 ( r = 0.27; P = 0.03). aCMRO 2 was significantly lower after neonatal palliation [4.0 AU (2.1-6.3) vs 4.9 AU (2.2-15.6); P = 0.02]. According to our experience, combined photospectrometry and laser Doppler flowmetry enable non-invasive assessment of cerebral oxygen metabolism. The method promises new insights into perioperative cerebral perfusion following palliation or corrective surgery in infancy. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Sommer, Björn; Kreuzer, Maximilian; Bischoff, Barbara; Wolf, Dennis; Schmitt, Hubert; Eyupoglu, Ilker Y; Rössler, Karl; Buchfelder, Michael; Ganslandt, Oliver; Wiendieck, Kurt
2017-01-01
Background Monitoring of cortical cerebral perfusion is essential, especially in neurovascular surgery. Study Aims To test a novel noninvasive laser-Doppler flowmetry and spectrophotometry device for feasibility during elective cerebral aneurysm surgery. Material and Methods In this prospective single-institution nonrandomized trial, we studied local cerebral microcirculation using the noninvasive laser-Doppler spectrophotometer "Oxygen-to-see" (O2C) in 20 consecutive patients (15 female, 5 male; median age: 60.5 ± 11.7 years) who were operated on for incidental cerebral aneurysms. Capillary-venous oxygenation (oxygen saturation ["SO 2 "]), postcapillary venous filling pressures (relative hemoglobin content ["rHb"]), blood cell velocity ("velo"), and blood flow ("flow") were measured in 7-mm tissue depth using a subdural fiberoptic probe. Results Representative recordings were acquired immediately after dural opening over a median time span of 88 ± 21.8 seconds (range: 60-128 seconds) before surgical manipulation. Baseline values (median ± 2 standard deviations) of brain perfusion as measured with the O2C device were SO 2 , 39 ± 16.6%; rHb, 53 ± 18.6 arbitrary units (AU); velo, 60 ± 20.4 AU; and flow, 311 ± 72.8 AU. Placement of the self-retaining retractor led to a decrease in SO 2 of 17% ± 29% ( p < .05) and flow of 10% ± 11% ( p < .01); rHb increased by 18% ± 20% ( p < .01), and velo remained unchanged. Retractor removal caused the opposite with an increased flow of 10% ± 7% ( p < 0.001) and velo (3% ± 6%, p = 0.11), but a decrease in SO 2 of 24% ± 33% ( p = 0.09) and rHb of 12% ± 20% ( p =0.18). No neurologic or surgical complications occurred. Conclusion Using this novel noninvasive system, we were able to measure local cerebral microcirculation during aneurysm surgery. Our data indicate that this device is able to detect changes during routine neurosurgical maneuvers. Thus it may be useful for early detection of cerebral microcirculatory disturbances. Georg Thieme Verlag KG Stuttgart · New York.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banic, A.; Kouris, K.; Lewis, D.H.
1990-10-01
The aim of the study was experimentally to evaluate the capability and reliability of laser Doppler flowmetry (LDF) in conditions of circulatory deficiency, by correlating it to flow-related parameters measured by a radionuclide-imaging technique and using 99m-Tc red blood cells (RBCs). For this purpose, a pedicle island flap in the sheep was used, with well-perfused proximal parts and with evident stasis in the distal third of the flap. No correlation was found between results obtained with the two techniques. In regions with evident stasis, falsely high LDF readings were recorded. This may be due to a back-and-forth motion of themore » RBCs under the probe, rather than to true flow. It was concluded that, while LDF seems reliable in detecting complete arterial occlusion, it is unreliable in predicting either complete venous occlusion or partial obstruction of the flow to and from the flap. Clinical use for this purpose cannot be recommended.« less
Wavelet-analysis of gastric microcirculation in rats with ulcer bleedings
NASA Astrophysics Data System (ADS)
Pavlov, A. N.; Semyachkina-Glushkovskaya, O. V.; Pavlova, O. N.; Bibikova, O. A.; Kurths, J.
2013-10-01
Nitric oxide (NO) plays an important role in regulation of central and peripheral circulation in normal state and during hemorrhagic stress. Because the impaired gastric mucosal blood flow is the major cause of gastroduodenal lesions including ulcer bleeding (UB), we study in this work the NO-ergic mechanism responsible for regulation of this blood flow. Our study is performed in rats with a model of stress-induced UB using laser Doppler flowmetry (LDF) that characterizes the rate of blood flow by measuring a Doppler shift of the laser beam scattered by the moving red blood cells. Numerical analysis of LDF-data is based on the discrete wavelet-transform (DWT) using Daubechies wavelets aiming to quantify influences of NO on the gastric microcirculation. We show that the stress-induced UB is associated with an increased level of NO in the gastric tissue and a stronger vascular sensitivity to pharmacological modulation of NO-production by L-NAME. We demonstrate that wavelet-based analyses of NO-dependent regulation of gastric microcirculation can provide an effective endoscopic diagnostics of a risk of UB.
The influence of local pressure on evaluation parameters of skin blood perfusion and fluorescence
NASA Astrophysics Data System (ADS)
Zherebtsov, E. A.; Kandurova, K. Y.; Seryogina, E. S.; Kozlov, I. O.; Dremin, V. V.; Zherebtsova, A. I.; Dunaev, A. V.; Meglinski, I.
2017-03-01
This article presents the results of the study of the pressure applied on optical diagnostic probes as a significant factor affecting the results of measurements. During stepwise increasing and decreasing of local pressure on skin we conducted measurements using the methods of laser Doppler flowmetry and fluorescence spectroscopy. It was found out that pressure on optical probe has sufficient impact on skin microcirculation to affect registered fluorescence intensity. Data obtained in this study are of interest for design and development of diagnostic technologies for wearable devices. This data will also inform further investigation into issues of compensation of blood absorption influence on fluorescence spectrum, allowing increased accuracy and reproducibility of measurements by fluorescence spectroscopy methods in optical diagnosis.
[Application of cryogenic stimulation in treatment of chronic wounds].
Vinnik, Iu S; Karapetian, G E; Iakimov, S V; Sychev, A G
2008-01-01
The authors have studied alterations occurring both in the ultrastructure of the cell matrix and in the microcirculatory bed of the chronic wound after local exposure to cryoagent. The up-to-date effective methods including laser Doppler flowmetry were used followed by correct statistical processing of the data obtained. The cryogenic stimulation of the wound was shown to result in considerably improved perfusion of the microcirculatory bed, epithelization and remodeling of the scar. It allowed transformation of a chronic process into acute and thus led to considerably accelerated process of regeneration. The developed method of cryogenic treatment of the chronic wound was used in 35 patients, allowed quicker healing of the chronic wounds and made ambulatory treatment of the patients 3 weeks shorter.
Neimark, A I; Nepomnyashchikh, L M; Lushnikova, E L; Bakarev, M A; Abdullaev, N A; Sizov, K A
2014-01-01
Structural reorganization of the bladder mucosa in chronic cystitis and its correction by ozone therapy were studied. A relationship between the epithelial layer restructuring of different kinds (dystrophy, metaplasia, and degeneration), level of cell proliferation, and ultrastructural organization of urotheliocytes was detected. This complex of structural reactions was combined with dysregulation of tissue bloodflow in the bladder mucosa, shown by laser Doppler flowmetry. Positive structural changes were most marked in intravesical and less so in parenteral ozone therapy added to the therapeutic complex and manifested in reduction of inflammation and alteration in parallel with more intense reparative reactions. A special feature of parenteral ozone therapy was a significant improvement of microcirculation in the bladder mucosa.
Kryvoruchko, I A; Goncharova, N M; Andreyeshchev, S A; Yavorska, T P
2015-05-01
Investigations were conducted in 37 patients, suffering complicated pancreatic pseudocysts. In accordance to data of ultrasound Doppler flowmetry for the blood flow along portal vein, a. hepatis communis, a. mesenterica superior in complicated pancreatic pseudocysts compensatory--adaptive reactions on level of hepatic--spanchnic blood flow are directed towards restriction of the blood inflow through the portal vein system. This is accompanied by the common peripheral vascular resistence raising in basin of a. mesenterica superior, which have depended upon the patients' state severity, caused by reduction of the volume blood flow in a certan vascular collector. The oxygen debt of the liver in these patients is compensated by the volume blood flow enhancement along a. hepatis communis.
Rafael, E; Gazelius, B; Wu, G S; Tibell, A
2000-01-01
Encapsulation of cellular grafts in an immunoisolation membrane device may make it possible to perform transplantation without having to give immunosuppressive drugs. A common problem is the development of an avascular fibrotic zone around the implants, leading to impaired graft survival. The TheraCyte macroencapsulation device has therefore been designed to facilitate neovascularization of the device's surface. In this study, we evaluated the microcirculation around empty TheraCyte devices implanted SC in rats at various times after implantation, using a laser Doppler probe introduced via the device port. Studies were performed on day 1 or at 1, 2, and 4 weeks or at 2, 3, and 12 months after implantation. The mean flow was 158+/-42, 148+/-50, 133+/-28, 72+/-17, 138+/-41, 165+/-43, and 160+/-29 perfusion units (PU), respectively. Thus, the microcirculation around the device was significantly reduced at 4 weeks after implantation (p < 0.01) while, from 2 months onwards the circulation had improved and did not differ significantly from that on day 1. The present study shows time-related changes in the microcirculatory flow around TheraCyte macroencapsulation devices that agree with our previous microdialysis studies on in vivo exchange of insulin and glucose between the device and the circulation. Laser Doppler flowmetry seems to provide a reliable technique for screening blood perfusion around macroencapsulation devices.
NASA Astrophysics Data System (ADS)
Folgosi-Correa, M. S.; Nogueira, G. E. C.
2012-06-01
The laser Doppler flowmetry allows the non-invasive assessment of the skin perfusion in real-time, being an attractive technique to study the human microcirculation in clinical settings. Low-frequency oscillations in the laser Doppler blood flow signal from the skin have been related to the endothelial, endothelial-metabolic, neurogenic and myogenic mechanisms of microvascular flow control, in the range 0.005-0.0095 Hz, 0.0095-0.021 Hz, 0.021-0.052 Hz and 0.052- 0.145 Hz respectively. The mean Amplitude (A) of the periodic fluctuations in the laser Doppler blood flow signal, in each frequency range, derived from the respective wavelet-transformed coefficients, has been used to assess the function and dysfunctions of each mechanism of flow control. Known sources of flow signal variances include spatial and temporal variability, diminishing the discriminatory capability of the technique. Here a new time domain method of analysis is proposed, based on the Time of Correlation (TC) of flow fluctuations between two adjacent sites. Registers of blood flow from two adjacent regions, for skin temperature at 32 0C (basal) and thermally stimulated (42 0C) of volar forearms from 20 healthy volunteers were collected and analyzed. The results obtained revealed high time of correlation between two adjacent regions when thermally stimulated, for signals in the endothelial, endothelial-metabolic, neurogenic and myogenic frequency ranges. Experimental data also indicate lower variability for TC when compared to A, when thermally stimulated, suggesting a new promising parameter for assessment of the microvascular flow control.
NASA Astrophysics Data System (ADS)
Yang, Victor X.; Gordon, M. L.; Qi, B.; Yue, E. Seng; Tang, S.; Bisland, Stuart K.; Pekar, J.; Lo, S.; Marcon, Norman E.; Wilson, B.; Vitkin, Alex
2003-07-01
Background: Currently clinical Doppler ultrasound cannot detect microvascular blood flow and it is difficult to provide depth discrimination using laser Doppler flowmetry. Doppler optical coherence tomography (DOCT) is a novel technique for noninvasive subsurface imaging of microcirculation and tissue structure. Aims: To design handheld and catheter-based DOCT probes for clinical cutaneous and endoscopic imaging. To develop signal processing techniques for real-time detection and quantification of microvascular blood flow. Methods: A DOCT system, with interchangeable cutaneous and catheter probes, was developed. The axial spatial resolution was 10 μm, and the velocity resolution was 20 μm/s, using a 1300 nm broadband infrared light. The system achieved real-time imaging with frame rates up to 32 Hz at 512 x 256 pixels per frame. We used the system to detect microcirculation in human skin and rat esophagus, and to monitor microvascular responses to photodynamic therapy (PDT) in a rat tumor model. Results: We present experimental results from in vivo DOCT imaging of microcirculation in human skin arterio-venous malformations (AVM), normal rat esophagus, and a rat gliosarcoma PDT model. In the PDT model, we followed microvascular responses to PDT and observed differences in the microcirculation during and after therapy, which can have important implications for PDT dosimetry and treatment optimization. Conclusions: To our knowledge, this is the first demonstration of endoscopic catheter-based DOCT detection of microcirculation in vivo. In addition, AVM can be detected using handheld cutaneous DOCT probes under clinical settings. DOCT may serve as a real-time monitoring tool for PDT dosimetry, especially for vascular targeting photosensitizers.
Lambova, Sevdalina N
2016-01-01
Micro- and macrovascular pathology is a frequent finding in a number of common rheumatic diseases. Secondary Raynaud's phenomenon (RP) is among the most common symptoms in systemic sclerosis and several other systemic autoimmune diseases including a broad differential diagnosis. It should be also differential from other peripheral vascular syndromes such as embolism, thrombosis, etc., some of which lead to clinical manifestation of the blue toe syndrome. The current review discusses the instrumental methods for vascular assessments. Nailfold capillaroscopy is the only method among the imaging techniques that can be used for morphological assessment of the nutritive capillaries in the nailfold area. Laser-Doppler flowmetry and laser-Doppler imaging are methods for functional assessment of microcirculation, while thermography and plethysmography reflect both blood flow in peripheral arteries and microcirculation. Doppler ultrasound and angiography visualize peripheral arteries. The choice of the appropriate instrumental method is guided by the clinical presentation. The main role of capillaroscopy is to provide differential diagnosis between primary and secondary RP. In rheumatology, capillaroscopic changes in systemic sclerosis have been recently defined as diagnostic. The appearance of abnormal capillaroscopic pattern inherits high positive predictive value for the development of a connective tissue disease that is higher than the predictive value of antinuclear antibodies. In cases of abrupt onset of peripheral ischaemia, clinical signs of critical ischaemia, unilateral or lower limb involvement, Doppler ultrasound and angiography are indicated. The most common causes for such clinical picture that may be referred to rheumatologic consultation are the antiphospholipid syndrome, mimickers of vasculitides such as atherosclerosis with cholesterol emboli, and neoplasms.
NASA Astrophysics Data System (ADS)
Zherebtsova, Angelina I.; Zherebtsov, Evgeny A.; Dunaev, Andrey V.; Podmasteryev, Konstantin V.; Pilipenko, Olga V.; Krupatkin, Alexander I.; Khakhicheva, Lyudmila S.; Muradyan, Vadim F.
2016-04-01
Vasospastic disorders are a common class of rheumatic disease. These include syndromes such as vegetative dystonia, Raynaud's syndrome, vibration disease and rheumatoid arthritis among others. The aim of this work is to develop an original method of diagnosing the functional state of peripheral vessels of the fingers, based on the simultaneous recording of LDF- and thermograms during the occlusion test, for determining vascular disorders of rheumatological patients. A diagnostic method was developed for assessing the functional state of the peripheral vessels of fingers, based on carrying out occlusion test in a thermally stabilized environment, with simultaneous recording of signals of laser Doppler flowmetry and skin thermometry. To verify the diagnostic value of the proposed method, a series of experiments were carried out on 41 rheumatological patients: 5 male and 36 females (average age 56.0+/-12.2 years). The most common diagnoses in the patient group were rheumatoid arthritis, arthrosis, gout and systemic lupus erythematosus. The laser analyser of blood microcirculation "LAKK-02" (SPE "LAZMA" Ltd, Russia) and a custom developed multi-channel thermometry device for low inertia thermometry were used for experimental measurements. The measurements of cutaneous temperature and the index of microcirculation were performed on the distal phalanx of the third finger of the right hand. Occlusion tests were performed with water baths at 25 and 42 °C and a tonometer cuff with a pressure of 200-220 mmHg for 3 min on the upper arm. The results of experimental studies are presented and interpreted. These data indicate a violation of the blood supply regulation in the form of a pronounced tendency towards microvascular vasoconstriction in the fingers. Thus, the response displaying a tendency toward angiospasm among patients in the rheumatological diseases profile group was observed mainly in the most severe cases (49 % of this group). The prospects of the developed diagnostic method of microcirculatory disorders in rheumatic diseases are evaluated. Thus, cutaneous blood microcirculation and temperature measurements performed together can help in diagnosis of the functional state of peripheral vessels both in a healthy state and when expressing pathology.
Martini, Romeo; Bagno, Andrea
2018-04-14
The wavelet analysis has been applied to the Laser Doppler Fluxmetry for assessing the frequency spectrum of the flowmotion to study the microvascular function waves.Although the application of wavelet analysis has allowed a detailed evaluation of the microvascular function, its use does not seem to be yet widespread over the last two decades.Aiming to improve the diffusion of this methodology, we herein present a systematic review of the literature about the application of the wavelet analysis to the laser Doppler fluxmetry signal. A computer research has been performed on PubMed and Scopus databases from January 1990 to December 2017. The used terms for the investigation have been "wavelet analysis", "wavelet transform analysis", "Morlet wavelet transform" along with the terms "laser Doppler", "laserdoppler" and/or "flowmetry" or "fluxmetry". One hundred and eighteen studies have been found. After the scrutiny, 97 studies reporting data on humans have been selected. Fifty-three studies, 54.0% (95% CI 44.2-63.6) pooled rate, have been performed on 892 healthy subjects and 44, 45,9 % (95% CI 36.3-55.7%) pooled rate have been performed on 1679 patients. No significant difference has been found between the two groups (p 0,81). On average, the number of studies published each year was 4.8 (95% CI 3.4-6.2). The trend of studies production has increased significantly from 1998 to 2017, (p 0.0006). But only the studies on patients have shown a significant increase trend along the years (p 0.0003), than the studies on healthy subjects (p 0.09).In conclusion, this review highlights that despite being a promising and interesting methodology for the study of the microcirculatory function, the wavelet analysis has remained still neglected.
Rink, Cameron L; Wernke, Matthew M; Powell, Heather M; Tornero, Mark; Gnyawali, Surya C; Schroeder, Ryan M; Kim, Jayne Y; Denune, Jeffrey A; Albury, Alexander W; Gordillo, Gayle M; Colvin, James M; Sen, Chandan K
2017-07-01
Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial ( n = 5) and transfemoral ( n = 5) amputation were compared to able-limb controls ( n = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function.
Using a laser-Doppler flowmetry to measure pulsatile microcirculation on the kidney in rats
NASA Astrophysics Data System (ADS)
Jan, Ming-Yie; Chao, Pin-Tsun; Hsu, Tse-Lin; Wang, Yuh-Yin L.; Wang, Wei-Kung
2001-10-01
Although Laser Doppler flowmetery (LDF) been extensively used in measurement of microvascular blood flow of different tissues. However, due to some physiological vibrations, fast oscillations of the renal cortical flux (RCF) are hard to be measured. In the study, a commercial 3mW 780nm Laser Doppler flowmetery, with a single fiber and a de-vibration holder, was used to measure the pulsatile RCF in rats. Considering the fast response due to the heart rate of rats, the time constant (TC) was set to 0.05 second and thus the frequency response is up to 20Hz. Furthermore, a calibration standard and a static blood sample were also measured as the references without the pulsatile driving force. In order not to perturb the RCF with tiny momentum, the applying force that the fiber exerted on the renal surface was controlled below 100 dyne. To enhance the signal to noise ratio (SNR), an averaged periodogram was used to estimate the frequency components of the pulsatile microcirculation. It is found that the dominating fast oscillation of RCF is pulsatile and its harmonic components are directly correlated with those of the heartbeat (correlation coefficient =0.999, P<0.001, n=17). The result shows that, in the kidney, the pulsatile RCF is the dominating component of microcirculation oscillation and driven by the fast propagating blood pressure. This technique could be further utilized to analyze the pharmacological effect and hemodynamic parameters on renal function.
Schmitz, Emilija; Bischoff, Barbara; Wolf, Dennis; Schmitt, Hubert J; Eyupoglu, Ilker Y; Roessler, Karl; Buchfelder, Michael; Sommer, Björn
2017-11-01
Intraoperative monitoring of cerebral microcirculation in patients with subarachnoid hemorrhage (SAH) may predict the postoperative neurologic outcome. In this pilot study, we examined the value of a novel noninvasive real-time measurement technique for detecting changes in local microcirculation. We used the O2C (Oxygen to see) laser-Doppler spectrophotometry system in 14 patients with Hunt & Hess grade 2-5 SAH who underwent microsurgical cerebral aneurysm clipping. A subdural probe recorded capillary venous oxygenation (SO 2 ), relative hemoglobin concentration, blood cell velocity, and blood flow at a tissue depth of 7 mm. Data were recorded immediately before dural closure. We also recorded somatosensory evoked potentials (SEPs) with median and tibial nerve stimulation. Results were compared with neurologic performance, as measured on the modified Rankin Scale, at the day of discharge from the hospital and 12 months thereafter. Patient functional outcomes after discharge and 12 months were correlated with pathological decreased flow and increased SO 2 values. In 6 of 8 patients, microcirculatory monitoring parameters indicated ischemia during surgery, as shown by electrophysiological SEP changes and infarction detected on the postoperative computed tomography (CT) scan. Pathological SEP results correlated closely with infarct demarcation as seen on CT. Our results indicate the potential benefit of intraoperative combined laser-Doppler flowmetry and spectrophotometry for predicting postoperative clinical outcomes in this small patient sample. Larger-cohort testing is needed to verify our findings and show the possible merits of this novel method. Copyright © 2017 Elsevier Inc. All rights reserved.
Lotter, Oliver; Held, Manuel; Schiefer, Jennifer; Werner, Ole; Medved, Fabian; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Jaminet, Patrick; Rothenberger, Jens
2015-01-01
Currently, the diagnosis of burn depth is primarily based on a visual assessment and can be dependent on the surgeons' experience. The goal of this study was to determine the ability of laser Doppler flowmeter combined with a tissue spectrophotometer to discriminate burn depth in a miniature swine burn model. Burn injuries of varying depth, including superficial-partial, deep-partial, and full thickness, were created in seven Göttingen minipigs using an aluminium bar (100 °C), which was applied to the abdominal skin for periods of 1, 3, 6, 12, 30, and 60 seconds with gravity alone. The depth of injury was evaluated histologically using hematoxylin and eosin staining. All burns were assessed 3 hours after injury using a device that combines a laser light and a white light to determine blood flow, hemoglobin oxygenation, and relative amount of hemoglobin. The blood flow (41 vs. 124 arbitrary units [AU]) and relative amount of hemoglobin (32 vs. 52 AU) were significantly lower in full thickness compared with superficial-partial thickness burns. However, no significant differences in hemoglobin oxygenation were observed between these depths of burns (61 vs. 60%). These results show the ability of laser Doppler flowmeter and tissue spectrophotometer in combination to discriminate between various depths of injury in the minipig model, suggesting that this device may offer a valuable tool for burn depth assessment influencing burn management. © 2014 by the Wound Healing Society.
Twelve-hour reproducibility of retinal and optic nerve blood flow parameters in healthy individuals.
Luksch, Alexandra; Lasta, Michael; Polak, Kaija; Fuchsjäger-Mayrl, Gabriele; Polska, Elzbieta; Garhöfer, Gerhard; Schmetterer, Leopold
2009-11-01
The aim of the present study was to investigate the reproducibility and potential diurnal variation of optic nerve head and retinal blood flow parameters in healthy individuals over a period of 12 hr. We measured optic nerve head and retinal blood flow parameters in 16 healthy male non-smoking individuals at five time-points during the day (08:00, 11:00, 14:00, 17:00 and 20:00 hr). Outcome parameters were perimacular white blood cell flux (as assessed with the blue field entoptic technique), blood velocities in retinal veins (as assessed with bi-directional laser Doppler velocimetry), retinal arterial and venous diameters (as assessed with the retinal vessel analyser), optic nerve head blood flow, volume and velocity (as assessed with single point and scanning laser Doppler flowmetry) and blood velocities in the central retinal artery (as assessed with colour Doppler imaging). The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. No diurnal variation in optic nerve head or retinal blood flow was observed with any of the techniques employed. Coefficients of variation were between 1.6% and 18.5% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 3.7% to 78.2%. Our data indicate that in healthy individuals the selected techniques provide adequate reproducibility to be used in clinical studies. However, in patients with eye diseases and reduced vision the reproducibility may be considerably worse.
[Physiological features of skin ageing in human].
Tikhonova, I V; Tankanag, A V; Chemeris, N K
2013-01-01
The issue deals with the actual problem of gerontology, notably physiological features of human skin ageing. In the present review the authors have considered the kinds of ageing, central factors, affected on the ageing process (ultraviolet radiation and oxidation stress), as well as the research guidelines of the ageing changes in the skin structure and fuctions: study of mechanical properties, microcirculation, pH and skin thickness. The special attention has been payed to the methods of assessment of skin blood flow, and to results of investigations of age features of peripheral microhemodynamics. The laser Doppler flowmetry technique - one of the modern, noninvasive and extensively used methods for the assessmant of skin blood flow microcirculation system has been expanded in the review. The main results of the study of the ageing changes of skin blood perfusion using this method has been also presented.
Chen, Eugene; Abbott, Paul V.
2009-01-01
Dental pulp testing is a useful and essential diagnostic aid in endodontics. Pulp sensibility tests include thermal and electric tests, which extrapolate pulp health from sensory response. Whilst pulp sensibility tests are the most commonly used in clinical practice, they are not without limitations and shortcomings. Pulp vitality tests attempt to examine the presence of pulp blood flow, as this is viewed as a better measure of true health than sensibility. Laser Doppler flowmetry and pulse oximetry are examples of vitality tests. Whilst the prospect is promising, there are still many practical issues that need to be addressed before vitality tests can replace sensibility tests as the standard clinical pulp diagnostic test. With all pulp tests, the results need to be carefully interpreted and closely scrutinised as false results can lead to misdiagnosis which can then lead to incorrect, inappropriate, or unnecessary treatment. PMID:20339575
[Microcirculatory investigations in hemophilia patients].
Davydkin, I L; Kosiakova, Iu A
2012-01-01
to evaluate microcirculation (MC) and its influencing factors in hemophilia patients. In 44 hemophilia patients with recurrent hemarthrosis, laser Doppler flowmetry was used to evaluate resting MC above the index fingers, knee and ankle joints during an occlusion test, with allowance made for muscle and adipose tissue mass. The increased perfusion value above the afflicted joints was found to correspond to the phase of an exacerbation of posthemorrhagic inflammation and to be a risk factor of recurrent hemarrthrosis. Analysis of the occlusion test above the knee joints and index fingers revealed a diminished MC reserve and a tendency to precapillary spasm. MC changes were more pronounced in a shortage of muscle and adipose tissue mass. Hemophilia patients must regularly do physical exercises to make skeletal muscles develop well in order to prevent an exacerbation of the joint inflammatory process.
Analysis of skin blood microflow oscillations in patients with rheumatic diseases
NASA Astrophysics Data System (ADS)
Mizeva, Irina; Makovik, Irina; Dunaev, Andrey; Krupatkin, Alexander; Meglinski, Igor
2017-07-01
Laser Doppler flowmetry (LDF) has been applied for the assessment of variation in blood microflows in patients with rheumatic diseases and healthy volunteers. Oscillations of peripheral blood microcirculation observed by LDF have been analyzed utilizing a wavelet transform. A higher amplitude of blood microflow oscillations has been observed in a high frequency band (over 0.1 Hz) in patients with rheumatic diseases. Oscillations in the high frequency band decreased in healthy volunteers in response to the cold pressor test, whereas lower frequency pulsations prevailed in patients with rheumatic diseases. A higher perfusion rate at normal conditions was observed in patients, and a weaker response to cold stimulation was observed in healthy volunteers. Analysis of blood microflow oscillations has a high potential for evaluation of mechanisms of blood flow regulation and diagnosis of vascular abnormalities associated with rheumatic diseases.
NASA Astrophysics Data System (ADS)
Liu, Jian; Wang, Yi; Zhao, Yuqian; Dou, Shidan; Ma, Yushu; Ma, Zhenhe
2016-03-01
Activity of brain neurons will lead to changes in local blood flow rate (BFR). Thus, it is important to measure the local BFR of cerebral cortex on research of neuron activity in vivo, such as rehabilitation evaluation after stroke, etc. Currently, laser Doppler flowmetry is commonly used for blood flow measurement, however, relatively low resolution limits its application. Optical coherence tomography (OCT) is a powerful noninvasive 3D imaging modality with high temporal and spatial resolutions. Furthermore, OCT can provide flow distribution image by calculating Doppler frequency shift which makes it possible for blood flow rate measurement. In this paper, we applied OCT to measure the blood flow rate of the primary motor cortex in rats. The animal was immobilized and anesthetized with isoflurane, an incision was made along the sagittal suture, and bone was exposed. A skull window was opened on the primary motor cortex. Then, blood flow rate changes in the primary motor cortex were monitored by our homemade spectral domain OCT with a stimulation of the passive movement of the front legs. Finally, we established the relationship between blood flow rate and the test design. The aim is to demonstrate the potential of OCT in the evaluation of cerebral cortex function.
Hsiu, Hsin; Hu, Hsiao-Feng; Tsai, Hung-Chi
2018-01-01
This study performed laser-Doppler flowmetry (LDF) measurements with the aim of identifying differences in diabetes-induced microcirculatory-blood-flow (MBF) responses between the following skin surface measurement sites: an acupoint around the wrist, an acupoint around the ankle, and a nearby nonacupoint around the ankle. The 67 study subjects were assigned to diabetic, prediabetic, and healthy groups according to the results of oral glucose tolerance tests. Beat-to-beat and spectral analyses were applied to the LDF waveform to obtain the foot delay time (FDT), the flow rise time (FRT), and the relative energy contributions (RECs) in five frequency bands. FRT and FDT were significantly shorter and the RECs of the endothelial-, neural-, and myogenic-related frequency bands were significantly smaller in the diabetic group than in the control group at the acupoint around the ankle, but there were no such prominent differences at the other sites. The acupoint around the ankle was better than the nearby nonacupoint and the acupoint around the wrist for distinguishing the age-matched diabetic, prediabetic, and healthy subjects. These findings imply that when monitoring diabetes-induced MBF responses, the measurement locations should be chosen carefully in order to minimize interference effects and to improve the ability to distinguish subjects with different conditions. Copyright © 2017 Elsevier Inc. All rights reserved.
Characteristics in the beat-to-beat laser-Doppler waveform indices in subjects with diabetes.
Hsiu, Hsin; Hu, Hsiao-Feng; Wu, Guan-Shian; Hsiao, Fone-Ching
2014-01-01
The present study performed laser-Doppler flowmetry (LDF) measurements on the skin surface around the ankle with the aim of verifying if beat-to-beat analysis of the LDF waveform can help to discriminate the microcirculatory-blood-flow (MBF) characteristics between diabetic, prediabetic, and healthy subjects. 84 subjects were assigned to three groups (diabetic, prediabetic, and normal) according to the results of oral glucose tolerance tests. Beat-to-beat analysis was performed on the pulsatile LDF waveform to obtain foot delay time (FDT), flow rise time (FRT), and the corresponding MBF-variability parameters (FDTCV and FRTCV). Relative to the control group, FDT and FRT were significantly shorter in prediabetic subjects, FDT was significantly shorter in diabetic subjects, and FRTCV and FDTCV were significantly larger in prediabetic and diabetic subjects. There were no significant associations for FRT after adjustment for age and gender. The present results indicate that FRT may help to discriminate differences in the elastic properties of local vascular beds during diabetes or even during prediabetic stages. The proposed blood-filling-volume model can help to explain the underlying mechanism. The present findings may aid the noninvasive early detection of diabetes-associated vascular damage, and could be used in the development of home-care and telemedicine applications.
Postocclusive reactive hyperemia in hand-arm vibration syndrome.
Stoyneva, Zlatka
2016-01-01
To assess laser Doppler-recorded postocclusive reactive hyperemic responses in vibration-induced Raynaud's phenomenon and compare it with primary and secondary to sclerodermy Raynaud's phenomenon. Thirty patients with vibration-induced Raynaud's phenomenon and 30 healthy controls and patients with primary and secondary to sclerodermy Raynaud's phenomenon were investigated. Fingerpulp skin blood flow was monitored by laser Doppler flowmetry during postocclusive reactive hyperemia test. Lower initial perfusion values were established in all the patients with Raynaud's phenomenon compared to the healthy controls (p < 0.0001). The postocclusive reactive hyperemic peak was lower in all the Raynaud's phenomenon groups compared to the controls (p < 0.0001). The postocclusive and basal perfusions were lower in the secondary Raynaud's phenomenon groups compared to the control and the primary Raynaud's phenomenon groups (p < 0.0001). The velocities to postocclusive hyperemic peak were lower in all the Raynaud's phenomenon patients (p < 0.0001), so were in the vibration-induced (p < 0.002) and the sclerodermy Raynaud's phenomenon (p < 0.004) groups in relation to the primary Raynaud's phenomenon group. The perfusion values and the velocities were significantly influenced by the initial superficial skin temperatures and perfusions, while the velocities were dependent also on gender, and the hyperemic peak on age. Postocclusive reactive hyperemia is abnormal in all Raynaud's phenomenon patients. Laser Doppler-recorded reactive hyperemia test contributes to diagnosing Raynaud's phenomenon and has proved to be valuable for group analysis. The applied method is not sensitive enough to discriminate adequately the type of Raynaud's phenomenon among individual cases. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Fiber optic based multiprobe system for intraoperative monitoring of brain functions
NASA Astrophysics Data System (ADS)
Mayevsky, Avraham; Flamm, E. S.; Pennie, William; Chance, Britton
1991-05-01
Monitoring of brain functions during neurosurgical conditions have been made by various groups of investigators. Attempts were made to monitor EEG or evoked potentials, cerebral blood flow, mitochondrial redox state during various neurosurgical procedures. In order to monitor various functions of the brain we have developed a new multiprobe (MPA) assembly, based on fiber optic probes and ion selective electrodes, enabling the assessment of relative CBF, mitochondrial redox state (NADH fluorescence) and ion homeostasis in real-time, intraoperatively. The base features of the multiprobe assembly were described previously (A. Mayevsky, J. Appl. Physiol. 54, 740-748, 1983). The multiprobe holder (made of Delarin) contained a bundle of fibers transmitting light to and from the brain as well as 3 ion selective electrodes (K+%/, Ca(superscript 2+, Na+) combined with DC steady potential electrodes (Ag/AgCl). The common part of the light guide contained 2 groups of fibers. For the Laser Doppler flowmetry one input fiber and two output fibers were glued in a triangular shape and connected to the standard commercial plug of the Laser Doppler flowmeter. For the monitoring of NADH redox state 10 excitation and 10 emission fibers were randomly mixed between and around the fibers used for the Laser Doppler flowmetry. This configuration of the fibers enabled us to monitor CBF and NADH redox state from about the same tissue volume. The ion selective electrodes were connected to an Ag/AgCl electrode holders and the entire MPA was protected by a Plexiglass sleeve. Animal experiments were used for the verification of the methods and recording of typical responses to various pathological situations. The entire multiprobe assembly was sterilized by the standard gas sterilization routine and was checked for electrodes integrity and calibration inside the operation room 24 hours later. The MPA was located on the exposed human cortex using a micromanipulator and data collection started immediately after, using a micro computer based data acquisition system. After recording of baseline levels of CBF, NADH redox state and extracellular ion levels, the responses to CBF decrease (occlusions of a blood vessel) were recorded followed by the recovery period. A significant correlation between the CBF and NADH redox state changes was recorded. This approach enabled us to correlate this change in energy supply, to those of extracellular ion concentration. The preliminary results obtained suggest that the usage of the MPA in the operating room may have a significant contribution to the neurosurgeon as a routine diagnostic tool. It seems to us that a simplified MPA which will enable to monitor only the relative CBF, NADH redox state as well as extracellular K+ is more appropriate for future usage.
Takata, Norio; Nagai, Terumi; Ozawa, Katsuya; Oe, Yuki; Mikoshiba, Katsuhiko; Hirase, Hajime
2013-01-01
We report that a brief electrical stimulation of the nucleus basalis of Meynert (NBM), the primary source of cholinergic projection to the cerebral cortex, induces a biphasic cerebral cortical blood flow (CBF) response in the somatosensory cortex of C57BL/6J mice. This CBF response, measured by laser Doppler flowmetry, was attenuated by the muscarinic type acetylcholine receptor antagonist atropine, suggesting a possible involvement of astrocytes in this type of CBF modulation. However, we find that IP3R2 knockout mice, which lack cytosolic Ca2+ surges in astrocytes, show similar CBF changes. Moreover, whisker stimulation resulted in similar degrees of CBF increase in IP3R2 knockout mice and the background strain C57BL/6J. Our results show that neural activity-driven CBF modulation could occur without large cytosolic increases of Ca2+ in astrocytes.
Fluorescence endoscopic imaging for evaluation of gastric mucosal blood flow: a preliminary study
NASA Astrophysics Data System (ADS)
Bocquillon, Nicolas; Mordon, Serge R.; Mathieu, D.; Maunoury, Vincent; Marechal, Xavier-Marie; Neviere, Remi; Wattel, Francis; Chopin, Claude
1999-02-01
Microcirculatory disorders of the gastrointestinal tract appear to be a major compound of the multiple organ dysfunction syndrome secondary to sepsis or septic shock. A better analysis of mucosal hypoperfusion in critically ill patients with sepsis may be helpful for the comprehension of this high mortality-associated syndrome. Fluorescence endoscopy has been recognized as a non-invasive method for both spatial and temporal evaluation of gastrointestinal mucosal perfusion. We performed this imaging technique during routine gastric endoscopy in patients with sepsis criteria. The study included gastric observation and appearance time of gastric fluorescence after an intravenous 10% sodium - fluorescein bolus. Qualitative analysis of high fluorescence areas was compared with mucosal blood flow measurements by laser - Doppler flowmetry. We concluded that the fluorescence endoscopic imaging in critically ill patients with sepsis may reveal spacial and temporal differences in the mucosal microcirculation distribution.
NASA Astrophysics Data System (ADS)
Andrukhina, V. V.; Litvinova, K. S.; Nikitin, A. A.; Spiridonova, N. Z.; Rogatkin, D. A.
2009-10-01
The urgency of BCC study affecting maxillofacial area and neck is not only caused by high prevalence of this disease, but also insufficient efficiency of existing treatment methods which lead to full or partial recovery only in 60-80% of cases. We analyzed the results of 198 BCC cases cryosurgical treatment. 33 (16,6%) patients showed continued tumor growth. It has been hypothesized that the behavior and character of microcirculation changes during patient's testing have to correlate with damaging rate of tumors that will allow to develop indications for surgical treatment with local destruction - cryosurgery or cryolaser treatment. We have tested the new group of 33 patients with primary and recurrence types of basal cell carcinoma (BCC) by means of Laser Doppler Flowmetry, Tissues Reflectance Oximetry, Laser Fluorescence Diagnostics before operation. It was shown that the microcirculatory data indicates the presence of cryoresistance.
NASA Astrophysics Data System (ADS)
Andrukhina, V. V.; Litvinova, K. S.; Nikitin, A. A.; Spiridonova, N. Z.; Rogatkin, D. A.
2010-02-01
The urgency of BCC study affecting maxillofacial area and neck is not only caused by high prevalence of this disease, but also insufficient efficiency of existing treatment methods which lead to full or partial recovery only in 60-80% of cases. We analyzed the results of 198 BCC cases cryosurgical treatment. 33 (16,6%) patients showed continued tumor growth. It has been hypothesized that the behavior and character of microcirculation changes during patient's testing have to correlate with damaging rate of tumors that will allow to develop indications for surgical treatment with local destruction - cryosurgery or cryolaser treatment. We have tested the new group of 33 patients with primary and recurrence types of basal cell carcinoma (BCC) by means of Laser Doppler Flowmetry, Tissues Reflectance Oximetry, Laser Fluorescence Diagnostics before operation. It was shown that the microcirculatory data indicates the presence of cryoresistance.
Non-invasive diagnostic methods in dentistry
NASA Astrophysics Data System (ADS)
Todea, Carmen
2016-03-01
The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.
Disorders of cochlear blood flow.
Nakashima, Tsutomu; Naganawa, Shinji; Sone, Michihiko; Tominaga, Mitsuo; Hayashi, Hideo; Yamamoto, Hiroshi; Liu, Xiuli; Nuttall, Alfred L
2003-09-01
The cochlea is principally supplied from the inner ear artery (labyrinthine artery), which is usually a branch of the anterior inferior cerebellar artery. Cochlear blood flow is a function of cochlear perfusion pressure, which is calculated as the difference between mean arterial blood pressure and inner ear fluid pressure. Many otologic disorders such as noise-induced hearing loss, endolymphatic hydrops and presbycusis are suspected of being related to alterations in cochlear blood flow. However, the human cochlea is not easily accessible for investigation because this delicate sensory organ is hidden deep in the temporal bone. In patients with sensorineural hearing loss, magnetic resonance imaging, laser-Doppler flowmetry and ultrasonography have been used to investigate the status of cochlear blood flow. There have been many reports of hearing loss that were considered to be caused by blood flow disturbance in the cochlea. However, direct evidence of blood flow disturbance in the cochlea is still lacking in most of the cases.
NASA Astrophysics Data System (ADS)
Zharkikh, E. V.; Dremin, V. V.; Filina, M. A.; Makovik, I. N.; Potapova, E. V.; Zherebtsov, E. A.; Zherebtsova, A. I.; Dunaev, A. V.
2017-11-01
The paper shows the possibility of assessing the functional state of microcirculatory-tissue systems of patients with diabetes mellitus by laser Doppler flowmetry (LDF), diffuse reflectance spectroscopy (DRS) and fluorescence spectroscopy (FS) methods. A review of the existing non-invasive optical technologies used to assess the state of microcirculation and oxygen metabolism in tissues of patients with diabetes is conducted. A series of experimental studies involving 76 patients with diabetes and 46 healthy volunteers was carried out. A wavelet analysis of LDF-grams was used to evaluate the adaptive changes of microcirculation during the temperature tests. The obtained data revealed that the proposed methodology in the form of combined use of several diagnostic technologies (LDF, FS and DRS) allows us to detect the presence or absence of trophic disorders and to evaluate adaptation processes during thermal tests.
Broderick, Patricia A; Kolodny, Edwin H
2011-01-01
Neuromolecular Imaging (NMI) based on adsorptive electrochemistry, combined with Dual Laser Doppler Flowmetry (LDF) is presented herein to investigate the brain neurochemistry affected by enoxaparin (Lovenox(®)), an antiplatelet/antithrombotic medication for stroke victims. NMI with miniature biosensors enables neurotransmitter and neuropeptide (NT) imaging; each NT is imaged with a response time in milliseconds. A semiderivative electronic reduction circuit images several NT's selectively and separately within a response time of minutes. Spatial resolution of NMI biosensors is in the range of nanomicrons and electrochemically-induced current ranges are in pico- and nano-amperes. Simultaneously with NMI, the LDF technology presented herein operates on line by illuminating the living brain, in this example, in dorso-striatal neuroanatomic substrates via a laser sensor with low power laser light containing optical fiber light guides. NMI biotechnology with BRODERICK PROBE(®) biosensors has a distinct advantage over conventional electrochemical methodologies both in novelty of biosensor formulations and on-line imaging capabilities in the biosensor field. NMI with unique biocompatible biosensors precisely images NT in the body, blood and brain of animals and humans using characteristic experimentally derived half-wave potentials driven by oxidative electron transfer. Enoxaparin is a first line clinical treatment prescribed to halt the progression of acute ischemic stroke (AIS). In the present studies, BRODERICK PROBE(®) laurate biosensors and LDF laser sensors are placed in dorsal striatum (DStr) dopaminergic motor neurons in basal ganglia of brain in living animals; basal ganglia influence movement disorders such as those correlated with AIS. The purpose of these studies is to understand what is happening in brain neurochemistry and cerebral blood perfusion after causal AIS by middle cerebral artery occlusion in vivo as well as to understand consequent enoxaparin and reperfusion effects actually while enoxaparin is inhibiting blood clots to alleviate AIS symptomatology. This research is directly correlated with the medical and clinical needs of stroke victims. The data are clinically relevant, not only to movement dysfunction but also to the depressive mood that stroke patients often endure. These are the first studies to image brain neurotransmitters while any stroke medications, such as anti-platelet/anti-thrombotic and/or anti-glycoprotein are working in organ systems to alleviate the debilitating consequences of brain trauma and stroke/brain attacks.
Broderick, Patricia A.; Kolodny, Edwin H.
2011-01-01
Neuromolecular Imaging (NMI) based on adsorptive electrochemistry, combined with Dual Laser Doppler Flowmetry (LDF) is presented herein to investigate the brain neurochemistry affected by enoxaparin (Lovenox®), an antiplatelet/antithrombotic medication for stroke victims. NMI with miniature biosensors enables neurotransmitter and neuropeptide (NT) imaging; each NT is imaged with a response time in milliseconds. A semiderivative electronic reduction circuit images several NT’s selectively and separately within a response time of minutes. Spatial resolution of NMI biosensors is in the range of nanomicrons and electrochemically-induced current ranges are in pico- and nano-amperes. Simultaneously with NMI, the LDF technology presented herein operates on line by illuminating the living brain, in this example, in dorso-striatal neuroanatomic substrates via a laser sensor with low power laser light containing optical fiber light guides. NMI biotechnology with BRODERICK PROBE® biosensors has a distinct advantage over conventional electrochemical methodologies both in novelty of biosensor formulations and on-line imaging capabilities in the biosensor field. NMI with unique biocompatible biosensors precisely images NT in the body, blood and brain of animals and humans using characteristic experimentally derived half-wave potentials driven by oxidative electron transfer. Enoxaparin is a first line clinical treatment prescribed to halt the progression of acute ischemic stroke (AIS). In the present studies, BRODERICK PROBE® laurate biosensors and LDF laser sensors are placed in dorsal striatum (DStr) dopaminergic motor neurons in basal ganglia of brain in living animals; basal ganglia influence movement disorders such as those correlated with AIS. The purpose of these studies is to understand what is happening in brain neurochemistry and cerebral blood perfusion after causal AIS by middle cerebral artery occlusion in vivo as well as to understand consequent enoxaparin and reperfusion effects actually while enoxaparin is inhibiting blood clots to alleviate AIS symptomatology. This research is directly correlated with the medical and clinical needs of stroke victims. The data are clinically relevant, not only to movement dysfunction but also to the depressive mood that stroke patients often endure. These are the first studies to image brain neurotransmitters while any stroke medications, such as anti-platelet/anti-thrombotic and/or anti-glycoprotein are working in organ systems to alleviate the debilitating consequences of brain trauma and stroke/brain attacks. PMID:22346571
Ultrasonic Transit Time Flowmetry in Robotic Totally Endoscopic CABG
Chaikhouni, Amer; Almulla, Abdulwahid
2011-01-01
Successful use of transit time flowmetry in robotic totally endoscopic coronary bypass operation is reported to demonstrate its applicability and ease of use in evaluating the function of grafts in such operations. PMID:22121466
Koss, M C
2001-08-01
Experiments were undertaken to determine the role played by nitric oxide (NO) in basal ocular blood flow in the anterior aspect of the eye. Subsequent studies focused on existence of autoregulatory mechanisms and on the potential involvement of NO. Cats were anesthetized with pentobarbital (36 mg/kg, i.p.). A femoral artery and vein were cannulated for measuring blood pressure and for drug administration, respectively. Anterior segment blood flow was measured in a continuous fashion from the long posterior ciliary artery (LPCA) using ultrasonic flowmetry and from the anterior choroid using laser-Doppler flowmetry. A needle was placed into the anterior chamber, and autoregulatory mechanisms were studied by decreasing ocular perfusion pressure via stepwise elevations of IOP. Non-selective inhibition of NO synthase with L-NAME (20 mg/kg, i.v.) significantly decreased basal blood flow from both sites. L-NAME (5 mg/kg, i.v.) was without effect as was D-NAME (25 mg/kg, i.v.). Increasing IOP produced a linear decrease on LPCA blood flow indicating absence of autoregulation. In contrast, stepwise elevation of IOP produced a delayed, non-linear response in the anterior choroid suggestive of a strong autoregulatory response. Neither response to elevated ocular perfusion pressure was further altered by inhibition of NO synthase with L-NAME (20 mg/kg, i.v.). The results confirm previous reports that nitric oxide plays a pivotal role in maintenance of basal ocular blood flow. Autoregulation was not seen in the LPCA. In contrast, there was a clear autoregulatory response in the anterior choroid, although neither response was altered by inhibition of NO synthase.
Belcaro, G; D'Aulerio, A; Rulo, A; Candiani, C
1988-01-01
A new system to study capillary permeability, the VSC (vacuum suction chamber) device has been developed to evaluate the variations of capillary permeability in postphlebitic limbs. The VSC device produces by negative pressure [obtained in a plastic chamber applied to the skin at the perimalleolar region] a wheal which disappears in normals in less than one hour. In twelve patients with moderate [superficial] venous hypertension and in twelve patients with postphlebitic limbs the time of disappearance of the wheals was significantly longer in comparison with ten normal limbs. There was also a significantly increased time of disappearance of the wheals in postphlebitic legs in comparison with those with superficial incompetence. The validation of the VSC technique with venous occlusion plethysmography (VOP) showed that the increase of time of disappearance of the wheals is well correlated with the increase of capillary permeability demonstrated by VOP. After 2 weeks treatment with Venoruton (at the dosage of 1000 mg t.i.d.) the time of disappearance of the wheal was significantly reduced in both groups of patients (while it was unchanged in normals). Laser-Doppler parameters used together with the VSC device to evaluate the microcirculatory changes associated with an altered capillary permeability also showed a significant improvement of the laser-Doppler parameters after treatment. In conclusion there is evidence by the VSC device that capillary permeability [which is abnormally increased] in chronic venous hypertension is improved [decreased] after treatment for two weeks with Venoruton. This study demonstrated also the efficacy of the VSC device to study capillary permeability and the effects of drugs active on capillary permeability.
Noninvasive imaging analysis of biological tissue associated with laser thermal injury.
Chang, Cheng-Jen; Yu, De-Yi; Hsiao, Yen-Chang; Ho, Kuang-Hua
2017-04-01
The purpose of our study is to use a noninvasive tomographic imaging technique with high spatial resolution to characterize and monitor biological tissue responses associated with laser thermal injury. Optical doppler tomography (ODT) combines laser doppler flowmetry (LDF) with optical coherence tomography (OCT) to obtain high resolution tomographic velocity and structural images of static and moving constituents in highly scattering biological tissues. A SurgiLase XJ150 carbon dioxide (CO 2 ) laser using a continuous mode of 3 watts (W) was used to create first, second or third degree burns on anesthetized Sprague-Dawley rats. Additional parameters for laser thermal injury were assessed as well. The rationale for using ODT in the evaluation of laser thermal injury offers a means of constructing a high resolution tomographic image of the structure and perfusion of laser damaged skin. In the velocity images, the blood flow is coded at 1300 μm/s and 0 velocity, 1000 μm/s and 0 velocity, 700 μm/s and 0 velocity adjacent to the first, second, and third degree injuries, respectively. ODT produces exceptional spatial resolution while having a non-invasive way of measurement, therefore, ODT is an accurate measuring method for high-resolution fluid flow velocity and structural images for biological tissue with laser thermal injury. Copyright © 2017 Chang Gung University. Published by Elsevier B.V. All rights reserved.
Prospects for in vivo blood velocimetry using acoustic resolution photoacoustic Doppler
NASA Astrophysics Data System (ADS)
Brunker, J.; Beard, P.
2016-03-01
Acoustic resolution photoacoustic Doppler flowmetry (AR-PAF) is a technique that has the potential to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Previous work has shown the potential of the technique using blood-mimicking phantoms, but it has proved difficult to make accurate measurements in blood, and thus in vivo application has not yet been possible. One explanation for this difficulty is that whole blood is insufficiently heterogeneous. Through experimental measurements in red blood cell suspensions of different concentrations, as well as in whole blood, we provide new insight and evidence that refutes this assertion. We show that the velocity measurement accuracy is influenced by bandlimiting not only due to the detector frequency response, but also due to spatial averaging of absorbers within the detector field-of-view. In addition, there is a detrimental effect of limited light penetration, but this can be mitigated by selecting less attenuated wavelengths of light, and also by employing range-gating signal processing. By careful choice of these parameters as well as the detector centre frequency, bandwidth and field-of-view, it is possible to make AR-PAF measurements in whole blood using transducers with bandwidths in the tens of MHz range. These findings have profound implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions.
Control of cerebral cortical blood flow by stimulation of basal forebrain cholinergic areas in mice.
Hotta, Harumi; Uchida, Sae; Kagitani, Fusako; Maruyama, Naoki
2011-05-01
We examined whether activity of the nucleus basalis of Meynert (NBM) regulates regional cerebral cortical blood flow (rCBF) in mice, using laser speckle and laser Doppler flowmetry. In anesthetized mice, unilateral focal stimulation, either electrical or chemical, of the NBM increased rCBF of the ipsilateral cerebral cortex in the frontal, parietal and occipital lobes, independent of changes in systemic blood pressure. Most of vasodilative responses to low intensity stimuli (2 times threshold intensity: 2T) were abolished by atropine (a muscarinic cholinergic blocker), whereas responses to higher intensity stimuli (3T) were abolished by atropine and mecamylamine (a nicotinic cholinergic blocker). Blood flow changes were largest when the tip of the electrode was located within the area containing cholinergic neurons shown by choline acetyltransferase-immunocytochemistry. These results suggest that cholinergic projections from basal forebrain neurons in mice cause vasodilation in the ipsilateral cerebral cortex by a combination of muscarinic and nicotinic mechanisms, as previously found in rats and cats.
Low-pressure sequential compression of lower limbs enhances forearm skin blood flow.
Amah, Guy; Voicu, Sebastian; Bonnin, Philippe; Kubis, Nathalie
2016-12-01
We investigated whether forearm skin blood flow could be improved when a multilayer pulsatile inflatable suit was applied at a low pressure to the lower limbs and abdomen. We hypothesized that a non-invasive purely mechanical stimulation of the lower limbs could induce remote forearm blood flow modifications. The pulsatile suit induced a sequential compartmentalized low compression (65 mmHg), which was synchronized with each diastole of the cardiac cycle with each phase evolving centripetally (lower limbs to abdomen). Modifications of the forearm skin blood flow were continuously recorded by laser Doppler flowmetry (LDF) at baseline and during the pulsatile suit application. Endothelium-dependent and endothelium-independent vasodilations of the forearm skin microcirculation were measured by LDF in response to a local transdermal iontophoretic application of acetylcholine (ACh-test) and to hyperthermia (hyperT- test). Twenty-four healthy volunteers, 12 men and 12 women (43±14 years) were included in the study. LDF responses increased 1) under pulsatile suit (97±106%, p.
NASA Astrophysics Data System (ADS)
Potapova, E. V.; Dremin, V. V.; Zherebtsov, E. A.; Makovik, I. N.; Zharkikh, E. V.; Dunaev, A. V.; Pilipenko, O. V.; Sidorov, V. V.; Krupatkin, A. I.
2017-12-01
The possibility of a complex approach for studying changes in the system of blood microcirculation and metabolic processes in the biotissue of lower extremities using optical noninvasive methods of laser doppler flowmetry (LDF), fluorescence spectroscopy, and diffuse reflectance spectroscopy in combination with different modes of heating tests has been assessed. Seventy-six patients with type 2 diabetes mellitus, with 14 patients having visible trophic foot impairments, and 48 healthy volunteers have been examined. The parameters of LDF signals and spectra of fluorescence intensity and diffuse reflectance for foot skin have been analyzed. Statistically significant differences in the recorded parameters between the groups under study have been found. It has been concluded that combined application of noninvasive methods of spectroscopy could be used for diagnostics of complications both upon the occurrence of preliminary symptoms of diabetes, when pathological changes are still reversible, and in the presence of impairments to prevent aggravation of the disease and select an adequate correction of the treatment.
Human cutaneous vascular responses to whole-body tilting, Gz centrifugation, and LBNP
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.; Breit, Gregory A.; Buckley, Theresa M.; Ballard, Richard E.; Murthy, Gita; Hargens, Alan R.
2004-01-01
We hypothesized that gravitational stimuli elicit cardiovascular responses in the following order with gravitational stress equalized at the level of the feet, from lowest to highest response: short-(SAC) and long-arm centrifugation (LAC), tilt, and lower body negative pressure (LBNP). Up to 15 healthy subjects underwent graded application of the four stimuli. Laser-Doppler flowmetry measured regional skin blood flow. At 0.6 G(z) (60 mmHg LBNP), tilt and LBNP similarly reduced leg skin blood flow to approximately 36% of supine baseline levels. Flow increased back toward baseline levels at 80-100 mmHg LBNP yet remained stable during 0.8-1.0 G(z) tilt. Centrifugation usually produced less leg vasoconstriction than tilt or LBNP. Surprisingly, SAC and LAC did not differ significantly. Thigh responses were less definitive than leg responses. No gravitational vasoconstriction occurred in the neck. All conditions except SAC increased heart rate, according to our hypothesized order. LBNP may be a more effective and practical means of simulating cardiovascular effects of gravity than centrifugation.
Guinea pig cochlear blood flow under definite sound exposure-hydrogen clearance measurement.
Meyer, P; Kuhl, K D; Schmidt, R; Grützmacher, W
1991-01-01
Blood flow measurements were carried out on 18 coloured guinea pigs (8 animals served as control group) before and during definite sound exposure (12 kHz, 110 dB SPL). The exposure time amounted to 60 min. The anaesthesia was carried out according to the following schedule: a mixture consisting of 70 mg alpha-chloralose/kg b.w. and 400 mg urethane/kg b.w. was injected intraperitoneally. The relaxation was performed by means of i.p. application of 3 mg Tricuran/kg b.w./h. The hydrogen clearance measurements (HCM) were carried out under artificial respiration with control of arterial pH, endexpiratory CO2 content, as well as blood pressure and body temperature. After a duration of noise exposure of 30-45 min the cochlear blood flow reached an average level of 80% of the initial point. This level remained mainly unchanged until the end of noise exposure (60 min). Our HMC's confirm Laser Doppler flowmetry findings.
Jan, Yih-Kuen; Lee, Bernard; Liao, Fuyuan; Foreman, Robert D
2012-10-01
The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using the wavelet analysis of blood flow oscillations in rats. Twelve Sprague-Dawley rats were randomly assigned to three protocols, including pressure with local cooling (Δt = -10 °C), pressure with local heating (Δt = 10 °C) and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin blood flow was measured using laser Doppler flowmetry. The 3 h loading period was divided into non-overlapping 30 min epochs for the analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased under the conditions of pressure with heating and of pressure without temperature changes, but maintained stable under the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers.
Zachariae, R; Bjerring, P; Arendt-Nielsen, L
1989-11-01
Cutaneous reactivity against histamine skin prick test (Type I) and purified tuberculin protein derivative (Mantoux reaction, Type IV) was studied in eight volunteers under hypnosis. Types I and IV immunoreactivity were modulated by direct suggestion (Type I) and guided imagery (Type IV). The volunteers were highly susceptible subjects, selected by means of the Harvard Group Scale of Hypnotic Susceptibility, Form A. When the volunteers underwent hypnotic suggestion to decrease the cutaneous reaction to histamine prick test, a significant (P less than 0.02) reduction of the flare reaction (area of erythema) was observed compared with control histamine skin prick tests. The wheal reaction did not respond to hypnotic suggestion. Neither wheal nor flare reaction could be increased in size by hypnotic suggestion compared with control histamine skin prick tests. A hypnotic suggestion of increasing the Type IV reaction on one arm and decreasing the reaction on the other revealed a significant difference in both erythema size (P less than 0.02) and palpable induration (P less than 0.01). In two cases the reactions were monitored by laser doppler blood flowmetry and skin thickness measurement by ultrasound. The difference between the suggested increased and decreased reaction was 19% for the laser doppler bloodflow (in favor of the augmented side), and 44% for the dermal infiltrate thickness. This study objectively supports the numerous uncontrolled case reports of modulation of immunoreactivity in allergic diseases involving both Type I and Type IV skin reactions following hypnotic suggestions.
Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects
Polska, E; Polak, K; Luksch, A; Fuchsjager-Mayrl, G; Petternel, V; Findl, O; Schmetterer, L
2004-01-01
Aims/background: To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours. Methods: The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. Results: None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%. Conclusions: These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency. PMID:15031172
Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects.
Polska, E; Polak, K; Luksch, A; Fuchsjager-Mayrl, G; Petternel, V; Findl, O; Schmetterer, L
2004-04-01
To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours. The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%. These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency.
Jan, Yih-Kuen; Lee, Bernard; Liao, Fuyuan; Foreman, Robert D.
2012-01-01
The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using wavelet analysis of blood flow oscillations in rats. Twelve Sprague Dawley rats were randomly assigned into three protocols, including pressure with local cooling (Δt= −10°C), pressure with local heating (Δt= 10°C), and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 hours. Skin blood flow was measured using laser Doppler flowmetry. The 3-hour loading period was divided into non-overlapping 30 min epochs for analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased in the conditions of pressure with heating and of pressure without temperature changes, but maintained stable in the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers. PMID:23010955
Effect of maternal exercises on biophysical fetal and maternal parameters: a transversal study.
Santos, Caroline Mombaque Dos; Santos, Wendel Mombaque Dos; Gallarreta, Francisco Maximiliano Pancich; Pigatto, Camila; Portela, Luiz Osório Cruz; Morais, Edson Nunes de
2016-01-01
To evaluate the acute effects of maternal and fetal hemodynamic responses in pregnant women submitted to fetal Doppler and an aerobic physical exercise test according to the degree of effort during the activity and the impact on the well-being. Transversal study with low risk pregnant women, obtained by convenience sample with gestational age between 26 to 34 weeks. The participants carry out a progressive exercise test. After the exercise session, reduced resistance (p=0.02) and pulsatility indices (p=0.01) were identified in the umbilical artery; however, other Doppler parameters analyzed, in addition to cardiotocography and fetal biophysical profile did not achieve significant change. Maternal parameters obtained linear growth with activity, but it was not possible to establish a standard with the Borg scale, and oxygen saturation remained stable. A short submaximal exercise had little effect on placental blood flow after exercise in pregnancies without complications, corroborating that healthy fetus maintains homeostasis even in situations that alter maternal hemodynamics. Avaliar os efeitos agudos de respostas hemodinâmicas maternas e fetais em gestantes submetidas a Doppler fetal e a um teste de exercício físico aeróbio, de acordo com o grau de esforço durante a atividade e o impacto sobre o bem-estar. Estudo transversal desenvolvido com gestantes de baixo risco, por amostra de conveniência com idade gestacional entre 26 e 34 semanas. As participantes realizam um teste de esforço progressivo. Na artéria umbilical, após sessão de exercício físico, identificou-se a redução do índice de resistência (p=0,02) e do índice de pulsatilidade (p=0,01), mas os demais parâmetros Doppler analisados, além da cardiotocografia e do perfil biofísico fetal, não obtiveram alteração significativa. Os parâmetros maternos obtiveram crescimento linear com a atividade, mas não foi possível estabelecer padrão com a escala de Borg, e a saturação de oxigênio se manteve estável. O esforço submáximo curto teve pouco efeito sobre o fluxo de sangue da placenta após o exercício em gestações sem complicações, corroborando que o feto hígido mantém a homeostase mesmo em situações que alterem a hemodinâmica materna.
Bassani, Mariana Almada; Caldas, Jamil Pedro Siqueira; Netto, Abimael Aranha; Marba, Sérgio Tadeu Martins
2016-06-01
To assess the impact of respiratory therapy with the expiratory flow increase technique on cerebral hemodynamics of premature newborns. This is an intervention study, which included 40 preterm infants (≤34 weeks) aged 8-15 days of life, clinically stable in ambient air or oxygen catheter use. Children with heart defects, diagnosis of brain lesion and/or those using vasoactive drugs were excluded. Ultrasonographic assessments with transcranial Doppler flowmetry were performed before, during and after the increase in expiratory flow session, which lasted 5minutes. Cerebral blood flow velocity and resistance and pulsatility indices in the pericallosal artery were assessed. Respiratory physical therapy did not significantly alter flow velocity at the systolic peak (p=0.50), the end diastolic flow velocity (p=0.17), the mean flow velocity (p=0.07), the resistance index (p=0.41) and the pulsatility index (p=0.67) over time. The expiratory flow increase technique did not affect cerebral blood flow in clinically-stable preterm infants. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Robust optimal design of diffusion-weighted magnetic resonance experiments for skin microcirculation
NASA Astrophysics Data System (ADS)
Choi, J.; Raguin, L. G.
2010-10-01
Skin microcirculation plays an important role in several diseases including chronic venous insufficiency and diabetes. Magnetic resonance (MR) has the potential to provide quantitative information and a better penetration depth compared with other non-invasive methods such as laser Doppler flowmetry or optical coherence tomography. The continuous progress in hardware resulting in higher sensitivity must be coupled with advances in data acquisition schemes. In this article, we first introduce a physical model for quantifying skin microcirculation using diffusion-weighted MR (DWMR) based on an effective dispersion model for skin leading to a q-space model of the DWMR complex signal, and then design the corresponding robust optimal experiments. The resulting robust optimal DWMR protocols improve the worst-case quality of parameter estimates using nonlinear least squares optimization by exploiting available a priori knowledge of model parameters. Hence, our approach optimizes the gradient strengths and directions used in DWMR experiments to robustly minimize the size of the parameter estimation error with respect to model parameter uncertainty. Numerical evaluations are presented to demonstrate the effectiveness of our approach as compared to conventional DWMR protocols.
NASA Astrophysics Data System (ADS)
Cordier, G.; Choi, J.; Raguin, L. G.
2008-11-01
Skin microcirculation plays an important role in diseases such as chronic venous insufficiency and diabetes. Magnetic resonance imaging (MRI) can provide quantitative information with a better penetration depth than other noninvasive methods, such as laser Doppler flowmetry or optical coherence tomography. Moreover, successful MRI skin studies have recently been reported. In this article, we investigate three potential inverse models to quantify skin microcirculation using diffusion-weighted MRI (DWI), also known as q-space MRI. The model parameters are estimated based on nonlinear least-squares (NLS). For each of the three models, an optimal DWI sampling scheme is proposed based on D-optimality in order to minimize the size of the confidence region of the NLS estimates and thus the effect of the experimental noise inherent to DWI. The resulting covariance matrices of the NLS estimates are predicted by asymptotic normality and compared to the ones computed by Monte-Carlo simulations. Our numerical results demonstrate the effectiveness of the proposed models and corresponding DWI sampling schemes as compared to conventional approaches.
Experimental studies of methemoglobinemia due to percutaneous absorption of sodium nitrite.
Saito, T; Takeichi, S; Nakajima, Y; Yukawa, N; Osawa, M
1997-01-01
Methemoglobin formation caused by a liniment solution containing sodium nitrite (30 g/L and 140 g/L) was studied in rats with normal or abraded skin, by measuring the methemoglobin concentration before and after application of liniment solutions with differing nitrite concentration. Each liniment solution (120 microL) was applied. Methemoglobin was measured for 180 minutes using a hemoximeter. Simultaneously, arterial blood pressure and cutaneous blood flow was measured by laser Doppler flowmetry and a pressure transducer. After the application of each liniment solution to normal skin, the methemoglobin concentration was not significantly modified depending on the time after application. Application of liniment solution to abraded skin (140 g/L) resulted in a marked increase in methemoglobin concentration. A remarkable decrease in arterial blood pressure and subcutaneous blood flow were observed after application of liniment solution to abraded skin (140 g/L). Each of these findings are characteristic of nitrite and they imply the percutaneous absorption of nitrite. Regardless of the nitrite concentration, the methemoglobin concentration was consistently higher in abraded skin than in normal skin.
Beiner, J M; Olgivy, C S; DuBois, A B
1997-03-01
In mammals, the cerebrovascular response to increases in intracranial pressure may take the form of the Cushing response, which includes increased mean systemic arterial pressure, bradycardia and diminished respirations. The mechanism, effect and value of these responses are debated. Using laser-Doppler flowmetry to measure cerebral blood flow, we analyzed the cardiovascular responses to intracranial pressure raised by epidural infusion of mock cerebrospinal fluid in the bluefish and in the rabbit, and compare the results. A decline in cerebral blood flow preceding a rise in mean systemic arterial pressure was observed in both species. Unlike bluefish, rabbits exhibit a threshold of intracranial pressure below which cerebral blood flow was maintained and no cardiovascular changes were observed. The difference in response between the two species was due to the presence of an active autoregulatory system in the cerebral tissue of rabbits and its absence in bluefish. For both species studied, the stimulus for the Cushing response seems to be a decrement in cerebral blood flow. The resulting increase in the mean systemic arterial pressure restores cerebral blood flow to levels approaching controls.
Light-induced fluorescence for pulpal diagnosis
NASA Astrophysics Data System (ADS)
Ebihara, Arata; Liaw, Lih-Huei L.; Krasieva, Tatiana B.; Wilder-Smith, Petra B. B.
2001-04-01
A direct non-histological means of pulpal diagnosis remains elusive to clinical practice. Clinical vitality testing remains limited to electric, thermal criteria, or laser Doppler flowmetry. The goal of these investigations was to determine the feasibility of using light-induced fluorescence as a non-invasive modality for pulpal evaluation. Such a capability would, for example, permit expanded use of pulpotomy/pulpectomy techniques. Clinically healthy and diseased human extirpated pulpal tissues were used in this study. After excision, they were rapidly frozen and standard cryosections prepared. Measurement of tissue excitation/emission characteristics was performed using spectrographic analysis. A low-light level fluorescence microscopy system was then used to image autofluorescence localization and intensity at optimal excitation/detection parameters. Excitation/detection parameters used in this study included 405/605, 405/635, 405/670, 440/550, and 440/635. Autofluorescence intensities in healthy tissues were significantly stronger than those in diseased tissues at optimal parameters. It is postulated that autofluorescence characteristics are related to pathology- related structural changes in the pulp. This work provides the basis for further investigation into the relation between autofluorescence, histology and clinical symptoms.
New intravascular flow sensor using fiber optics
NASA Astrophysics Data System (ADS)
Stenow, Erik N. D.
1994-12-01
A new sensor using fiber optics is suggested for blood flow measurements in small vessels. The sensor principle and a first evaluation on a flow model are presented. The new sensor uses small CO2 gas bubbles as flow markers for optical detection. When the bubbles pass an optical window, light emitted from one fiber is reflected and scattered into another fiber. The sensor has been proven to work in a 3 mm flow model using two 110 micrometers optical fibers and a 100 micrometers steel capillary inserted into a 1 mm guide wire. The evaluation of a sensor archetype shows that the new sensor provides a promising method for intravascular blood flow measurement in small vessels. The linearity for steady state flow is studied in the flow interval 30 - 130 ml/min. comparison with ultrasound Doppler flowmetry was performed for pulsatile flow in the interval 25 - 125 ml/min. with a pulse length between 0.5 and 2 s. The use of intravascular administered CO2 in small volumes is harmless because the gas is rapidly dissolved in whole blood.
Sen, Arindam; Capitano, Maegan L; Spernyak, Joseph A; Schueckler, John T; Thomas, Seneca; Singh, Anurag K; Evans, Sharon S; Hylander, Bonnie L; Repasky, Elizabeth A
2011-06-01
Human and rodent solid tumors often exhibit elevated interstitial fluid pressure (IFP). This condition is recognized as a prognostic indicator for reduced responses to therapy and decreased disease-free survival rate. In the present study, we tested whether induction of a thermoregulatory-mediated increase in tissue blood flow, induced by exposure of mice to mild environmental heat stress, could influence IFP and other vascular parameters within tumors. Using several murine tumor models, we found that heating results in a sustained reduction in tumor IFP correlating with increased tumor vascular perfusion (measured by fluorescent imaging of perfused vessels, laser Doppler flowmetry, and MRI) as well as a sustained reduction in tumor hypoxia. Furthermore, when radiation therapy was administered 24 hours postheating, we observed a significant improvement in efficacy that may be a result of the sustained reduction in tumor hypoxia. These data suggest, for the first time, that environmental manipulation of normal vasomotor function is capable of achieving therapeutically beneficial changes in IFP and microvascular function in the tumor microenvironment.
Cochlear blood flow and speech perception ability in cochlear implant users.
Nakashima, Tsutomu; Hattori, Taku; Sone, Michihiko; Asahi, Kiyomitsu; Matsuda, Naoko; Teranishi, Masaaki; Yoshida, Tadao; Kato, Ken; Sato, Eisuke
2012-02-01
The effect of cochlear blood flow (CBF) on speech perception ability in cochlear implant (CI) users has not been reported. We investigated various factors influencing speech perception including CBF in CI users. Eighty-two patients who received CI surgery at an academic hospital. CBF was measured during CI surgery using laser Doppler flowmetry. The speech perception level was measured after a sufficient interval after CI surgery. Multivariate analysis was used to evaluate the influences of age, duration of deafness, sex, cause of deafness, and CBF on the speech perception level. CBF decreased significantly with age but was not related to the speech perception level. In patients with congenital hearing loss, the speech perception level was significantly worse in children who received a CI at 3 years of age than in those who received a CI at 2 years of age or younger. Duration of deafness before CI surgery had deteriorative effects on the speech perception level. CBF may be associated with progression of hearing loss. However, measuring CBF during CI surgery is not useful for predicting postoperative speech perception.
Blood flow to the promontory in cochlear otosclerosis.
Nakashima, T; Sone, M; Fujii, H; Teranishi, M; Yamamoto, H; Otake, H; Sugiura, M; Naganawa, S
2006-04-01
To investigate Schwartze sign with measurements of blood flow to the promontory in patients with cochlear otosclerosis. Prospective clinical study. Tertiary referral centre. Five patients with cochlear otosclerosis and five control subjects. Significant decalcification around the cochlea was observed by computed tomography (CT) in patients with cochlear otosclerosis. However, no recognizable lesion was observed at the oval window in two patients. One patient had mixed hearing loss and four patients had sensorineural hearing loss without an air-bone gap. The relationship between CT findings and the presence or absence of Schwartze sign was investigated. Blood flow to the promontory was measured through the tympanic membrane using laser speckle flowgraphy and laser Doppler flowmetry. The Schwartze sign correlated significantly with otosclerotic lesions invading the promontory. Patients with otosclerosis exhibited elevated and pulsating blood flow to the promontory with the Schwartze sign. Computed tomography demonstrated that cochlear otosclerosis can exist without the oval window lesion. Schwartze sign can be used as a sign of the otosclerotic invasion to the promontory. The reddening of the Schwartze sign is likely due to increased blood flow.
Horváth, Eszter Mária; Mágenheim, Rita; Domján, Beatrix Annamária; Ferencz, Viktória; Tänczer, Tímea; Szabó, Eszter; Benkő, Rita; Szabó, Csaba; Tabák, Ádám; Somogyi, Anikó
2015-11-22
Oxidative-nitrative stress and poly(ADP-ribose) polymerase activation observed in gestational diabetes may play role in the increased cardiovascular risk in later life. The present study aimed to examine the influence of the severity of previous gestational diabetes (insulin need) on vascular function three years after delivery. Furthermore, the authors investigated the relation of vascular function with oxidative-nitrative stress and poly(ADP-ribose) polymerase activation. Macrovascular function was measured by applanation tonometry; microvascular reactivity was assessed by provocation tests during Laser-Doppler flowmetry in 40 women who had gestational diabetes 3 years before the study. Oxidative-nitrative stress and poly(ADP-ribose) polymerase activity in blood components were determined by colorimetry and immunohistochemistry. Three years after insulin treated gestational diabetes impaired microvascular function and increased oxidative stress was observed compared to mild cases. The severity of previous gestational diabetes affects microvascular dysfunction that is accompanied by elevated oxidative stress. Nitrative stress and poly(ADP-ribose) polymerase activity correlates with certain vascular factors not related to the severity of the disease.
Effects of endothelium-derived nitric oxide on skin and digital blood flow in humans.
Coffman, J D
1994-12-01
The effects of NG-monomethyl-L-arginine (L-NMMA) on total finger and forearm, and dorsal finger and forearm skin, blood flows were studied in the basal state and during reflex sympathetic vasoconstriction in normal subjects. Total flows were measured by venous occlusion plethysmography and skin flows by laser-Doppler flowmetry (LDF). L-NMMA in doses of 2, 4, and 8 microM/min given by constant infusion via a brachial artery catheter significantly decreased finger blood flow, forearm blood flow, and vascular conductances. At 8 microM/min, total finger blood flow decreased 38.4% and forearm blood flow decreased 24.8%. Dorsal finger and forearm skin LDF were also significantly decreased (25 and 37% at 8 microM/min). Body cooling significantly decreased finger blood flow (73.6%), vascular conductance, and finger LDF (59.7%). L-NMMA had no effect on total finger blood flow or dorsal finger LDF during body cooling. Nitric oxide or related compounds contribute to the basal dilator tone of the dorsal finger and forearm skin but not during reflex sympathetic vasoconstriction.
Protective effect of estrogen in endothelin-induced middle cerebral artery occlusion in female rats.
Glendenning, Michele L; Lovekamp-Swan, Tara; Schreihofer, Derek A
2008-11-14
Estrogen is a powerful endogenous and exogenous neuroprotective agent in animal models of brain injury, including focal cerebral ischemia. Although this protection has been demonstrated in several different treatment and injury paradigms, it has not been demonstrated in focal cerebral ischemia induced by intraparenchymal endothelin-1 injection, a model with many advantages over other models of experimental focal ischemia. Reproductively mature female Sprague-Dawley rats were ovariectomized and divided into placebo and estradiol-treated groups. Two weeks later, halothane-anesthetized rats underwent middle cerebral artery (MCA) occlusion by interparenchymal stereotactic injection of the potent vasoconstrictor endothelin 1 (180pmoles/2microl) near the middle cerebral artery. Laser-Doppler flowmetry (LDF) revealed similar reductions in cerebral blood flow in both groups. Animals were behaviorally evaluated before, and 2 days after, stroke induction, and infarct size was evaluated. In agreement with other models, estrogen treatment significantly reduced infarct size evaluated by both TTC and Fluoro-Jade staining and behavioral deficits associated with stroke. Stroke size was significantly correlated with LDF in both groups, suggesting that cranial perfusion measures can enhance success in this model.
Efficiency of herbal medicine Dai-kenchu-to on portal blood flow in rat models.
Muraoka, Izumi; Takatsuki, Mitsuhisa; Soyama, Akihiko; Yamaguchi, Izumi; Tanaka, Shiro; Tanaka, Takayuki; Kinoshita, Ayaka; Hara, Takanobu; Kuroki, Tamotsu; Eguchi, Susumu
2015-09-01
To clarify the influence of Dai-Kenchu-To (DKT) on portal blood flow (PBF), PBF was continuously measured with Doppler ultrasound. Normal liver rats were divided into a DKT 90 mg/kg, DKT 270 mg/kg administered group, and control, while cirrhotic liver rats were divided into a DKT-LC 90 mg/kg administered group and Control-LC. The PBF was measured after the administration of either DKT or water for 60 min by laser Doppler flowmetry system. The PBF in the DKT 90 increased approximately 10 min after DKT was administrated, and elevated levels were maintained for approximately 10 min. A comparison of the increase in PBF by the calculating the area under the curve (AUC) revealed that flow was significantly higher in the DKT 90 compared to either the control or the DKT 270 (p < 0.05). The cirrhotic liver group showed stable PBF in both the DKT-LC and Control-LC. The AUC, revealed no significant difference between the DKT-LC and Control-LC. DKT induced an increase in PBF in normal livers; however, its effects were insufficient to increase PBF in the cirrhotic livers. No increase in the portal blood flow in the cirrhotic liver rats was probably the result of the cirrhotic liver, which had fibrotic change, and, therefore, may not have had sufficient compliance to accept the increasing blood flow volume from the intestinal tract. We suggested DKT has the potential to protect the liver by increasing PBF when the liver has either normal or mild to moderate dysfunction.
Choroidal microcirculation in patients with rotary cardiac assist device.
Polska, Elzbieta; Schima, Heinrich; Wieselthaler, Georg; Schmetterer, Leopold
2007-06-01
In recent years, fully implanted rotary blood pumps have been used for long-term cardiac assist in patients with end-stage heart failure. With these pumps, the pulsatility of arterial blood flow and arterial pressure pulse is considerably reduced. Effects on end-organ perfusion, particularly microcirculation, have been assessed. The ocular choroid offers a unique opportunity to study the pulsatile component of blood flow by measurement of fundus pulsation amplitude (FPA) as well as the microcirculation by laser Doppler flowmetry. Both techniques were applied in three male patients with rotary pumps (MicroMed DeBakey VAD), in whom pump velocity was adjusted to four levels of flow between individual minimal need and maximal support. In addition, blood flow velocities in the ophthalmic artery (peak, end-diastolic and mean flow velocity--PSV, EDV and MFV, respectively) were measured using color Doppler imaging. Systolic blood pressure increased by 6 to 22 mm Hg with increasing support. At maximal support FPA was reduced by -60% to -52% as compared with minimal pump support. Blood flow in the choroidal microvasculature, however, did not show relevant changes. A reduction in PSV (-31%, range -47% to -21%) and a pronounced rise in EDV (+93%, range +28% to +147%) was observed, whereas MFV was independent of pump flow. Our data indicate that mean choroidal blood flow is maintained when pump support is varied within therapeutic values, whereas the ratio of pulsatile to non-pulsatile choroidal flow changes. This study shows that, in patients with ventricular assist devices, a normal perfusion rate in the ocular microcirculation is maintained over a wide range of support conditions.
Design of a tissue oxygenation monitor and verification on human skin
NASA Astrophysics Data System (ADS)
Liu, Hongyuan; Kohl-Bareis, Matthias; Huang, Xiabing
2011-07-01
We report the design of a tissue oxygen and temperature monitor. The non-invasive, fibre based device monitors tissue haemoglobin (Hb) and oxygen saturation (SO2) and is based on white-light reflectance spectroscopy.Visible light with wavelengths in the 500 - 650nm range is utilized. The spectroscopic algorithm takes into account the tissue scattering and melanin absorption for the calculation of tissue haemoglobin concentration and oxygen saturation. The monitor can probe superficial layers of tissue with a high spatial resolution (mm3) and a high temporal resolution (40 Hz). It provides an accurate measurement with the accuracy of SO2 at 2 % and high reliability with less than 2 % variation of continuous SO2 measurement over 12 hours. It can also form a modular system when used in conjunction with a laser Doppler monitor, enabling simultaneous measurements of Hb, SO2 and blood flow. We found experimentally that the influence of the source-detector separation on the haemoglobin parameters is small. This finding is discussed by Monte Carlo simulations for the depth sensitivity profile. The influence of probe pressure and the skin pigmentation on the measurement parameters are assessed before in vivo experimental data is presented. The combination with laser Doppler flowmetry demonstrates the importance of a measurement of both the haemoglobin and the blood flow parameters for a full description of blood tissue perfusion. This is discussed in experimental data on human skin during cuff occlusion and after hyperemisation by a pharmacological cream. Strong correlation is observed between tissue oxygen (Hb and SO2) and blood flow measurements.
Sedlacik, Jan; Reitz, Matthias; Bolar, Divya S; Adalsteinsson, Elfar; Schmidt, Nils O; Fiehler, Jens
2015-03-01
The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7 T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml · kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s(∧)-1] = 20.7/20.4/20.1, R2*[s(∧)-1] = 31.6/29.6/25.9, R2'[s-(∧)1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml · min(∧)-1 · 100 g(∧)-1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood oxygenation level. We found good correlation between MRI and micro probe measurements. However, direct conversion of tissue pO2 to blood oxygen saturation by using the Hill equation is very limited. Furthermore, adverse effects of anesthesia and trauma due to micro probe insertion are strong confounding factors and need close attention for study planning and conduction of experiments. Investigation of the correlation of perfusion and oxygenation sensitive MRI methods with micro probe measurements in pathologic tissue such as tumors is now of compelling interest. Copyright © 2014. Published by Elsevier GmbH.
Pourabedian, Siyamak; Barkhordari, Abdullah; Habibi, Ehsanallah; Rismanchiyan, Masoud; Zare, Mohsen
2010-06-01
The aim of this study was to investigate the effects of occupational exposure to 1,6-hexamethylene diisocyanate (HDI) on peak flowmetry in automobile body paint shop workers in Iran. We studied a population of 43 car painters exposed to HDI at their workplaces. Peak expiratory flow was tested for one working week, from the start to the end of each shift. Air was sampled and HDI analysed in parallel, according to the OSHA 42 method. Daily and weekly HDI exposure averages were (0.42+/-0.1) mg m(-3) and (0.13+/-0.05) mg m(-3), respectively. On painting days, 72 % of workers showed more than a 10 % variation in peak expiratory flow. Inhalation exposure exceeded the threshold limit value (TLV) ten times over. This strongly suggests that HDI affected the peak flowmetry in the studied workers.
Hodges, Gary J.; Johnson, John M.
2015-01-01
The vascular response to local skin cooling is dependent in part on a cold-induced translocation of α2C-receptors and an increased α-adrenoreceptor function. To discover whether β-adrenergic function might contribute, we examined whether β-receptor sensitivity to the β-agonist isoproterenol was affected by local skin temperature. In seven healthy volunteers, skin blood flow was measured from the forearm by laser-Doppler flowmetry and blood pressure was measured by finger photoplethysmography. Data were expressed as cutaneous vascular conductance (CVC; laser-Doppler flux/mean arterial blood pressure). Pharmacological agents were administered via intradermal microdialysis. We prepared four skin sites: one site was maintained at a thermoneutral temperature of 34°C (32 ± 10%CVCmax) one site was heated to 39°C (38 ± 11%CVCmax); and two sites were cooled, one to 29°C (22 ± 7%CVCmax) and the other 24°C (16 ± 4%CVCmax). After 20 min at these temperatures to allow stabilization of skin blood flow, isoproterenol was perfused in concentrations of 10, 30, 100, and 300 μM. Each concentration was perfused for 15 min. Relative to the CVC responses to isoproterenol at the thermoneutral skin temperature (34°C) (+21 ± 10%max), low skin temperatures reduced (at 29°C) (+17 ± 6%max) or abolished (at 24°C) (+1 ± 5%max) the vasodilator response, and warm (39°C) skin temperatures enhanced the vasodilator response (+40 ± 9%max) to isoproterenol. These data indicate that β-adrenergic function was influenced by local skin temperature. This finding raises the possibility that a part of the vasoconstrictor response to direct skin cooling could include reduced background β-receptor mediated vasodilation. PMID:25701007
Methods of blood flow measurement in the arterial circulatory system.
Tabrizchi, R; Pugsley, M K
2000-01-01
The most commonly employed techniques for the in vivo measurement of arterial blood flow to individual organs involve the use of flow probes or sensors. Commercially available systems for the measurement of in vivo blood flow can be divided into two categories: ultrasonic and electromagnetic. Two types of ultrasonic probes are used. The first type of flow probe measures blood flow-mediated Doppler shifts (Doppler flowmetry) in a vessel. The second type of flow probe measures the "transit time" required by an emitted ultrasound wave to traverse the vessel and are transit-time volume flow sensors. Measurement of blood flow in any vessel requires that the flow probe or sensor be highly accurate and exhibit signal linearity over the flow range in the vessel of interest. Moreover, additional desirable features include compact design, size, and weight. An additional important feature for flow probes is that they exhibit good biocompatability; it is imperative for the sensor to behave in an inert manner towards the biological system. A sensitive and reliable method to assess blood flow in individual organs in the body, other than by the use of probes/sensors, is the reference sample method that utilizes hematogeneously delivered microspheres. This method has been utilized to a large extend to assess regional blood flow in the entire body. Obviously, the purpose of measuring blood flow is to determine the amount of blood delivered to a given region per unit time (milliliters per minute) and it is desirable to achieve this goal by noninvasive methodologies. This, however, is not always possible. This review attempts to offer an overview of some of the techniques available for the assessment of regional blood flow in the arterial circulatory system and discusses advantages and disadvantages of these common techniques.
Ahmed, A K; Goodwin, C R; Sarabia-Estrada, R; Lay, F; Ansari, A M; Steenbergen, C; Pang, C; Cohen, R; Born, L J; Matsangos, A E; Ng, C; Marti, G P; Abu-Bonsrah, N; Phillips, N A; Suk, I; Sciubba, D M; Harmon, J W
2016-12-01
Experimental study. The objective of this study was to establish a non-invasive model to produce pressure ulcers of varying severity in animals with spinal cord injury (SCI). The study was conducted at the Johns Hopkins Hospital in Baltimore, Maryland, USA. A mid-thoracic (T7-T9) left hemisection was performed on Sprague-Dawley rats. At 7 days post SCI, rats received varying degrees of pressure on the left posterior thigh region. Laser Doppler Flowmetry was used to record blood flow. Animals were killed 12 days after SCI. A cardiac puncture was performed for blood chemistry, and full-thickness tissue was harvested for histology. Doppler blood flow after SCI prior to pressure application was 237.808±16.175 PFUs at day 7. Following pressure application, there was a statistically significant decrease in blood flow in all pressure-applied groups in comparison with controls with a mean perfusion of 118.361±18.223 (P<0.001). White blood cell counts and creatine kinase for each group were statistically significant from the control group (P=0.0107 and P=0.0028, respectively). We have created a novel animal model of pressure ulcer formation in the setting of a SCI. Histological analysis revealed different stages of injury corresponding to the amount of pressure the animals were exposed to with decreased blood flow immediately after the insult along with a subsequent marked increase in blood flow the next day, conducive to an ischemia-reperfusion injury (IRI) and a possible inflammatory response following tissue injury. Following ischemia and hypoxia secondary to microcirculation impairment, free radicals generate lipid peroxidation, leading to ischemic tissue damage. Future studies should be aimed at measuring free radicals during this period of increased blood flow, following tissue ischemia.
Efficiency of herbal medicine Dai-kenchu-to on portal blood flow in rat models
Muraoka, Izumi; Takatsuki, Mitsuhisa; Soyama, Akihiko; Yamaguchi, Izumi; Tanaka, Shiro; Tanaka, Takayuki; Kinoshita, Ayaka; Hara, Takanobu; Kuroki, Tamotsu; Eguchi, Susumu
2015-01-01
Introduction To clarify the influence of Dai-Kenchu-To (DKT) on portal blood flow (PBF), PBF was continuously measured with Doppler ultrasound. Methods Normal liver rats were divided into a DKT 90 mg/kg, DKT 270 mg/kg administered group, and control, while cirrhotic liver rats were divided into a DKT-LC 90 mg/kg administered group and Control-LC. The PBF was measured after the administration of either DKT or water for 60 min by laser Doppler flowmetry system. Results The PBF in the DKT 90 increased approximately 10 min after DKT was administrated, and elevated levels were maintained for approximately 10 min. A comparison of the increase in PBF by the calculating the area under the curve (AUC) revealed that flow was significantly higher in the DKT 90 compared to either the control or the DKT 270 (p < 0.05). The cirrhotic liver group showed stable PBF in both the DKT-LC and Control-LC. The AUC, revealed no significant difference between the DKT-LC and Control-LC. Discussion DKT induced an increase in PBF in normal livers; however, its effects were insufficient to increase PBF in the cirrhotic livers. No increase in the portal blood flow in the cirrhotic liver rats was probably the result of the cirrhotic liver, which had fibrotic change, and, therefore, may not have had sufficient compliance to accept the increasing blood flow volume from the intestinal tract. Conclusion We suggested DKT has the potential to protect the liver by increasing PBF when the liver has either normal or mild to moderate dysfunction. PMID:26155361
Skin blood flow: a comparison of transcutaneous oximetry and laser Doppler flowmetry.
Allen, P I; Goldman, M
1987-10-01
In normal limbs skin blood flow (SBF) falls on standing, but in ischaemic limbs there is a characteristic blush on dependancy. We studied the effect of changing posture in a range of ischaemic limbs, using two non-invasive techniques--laser Doppler (LD) and transcutaneous oximetry (TcPO2). Warmed TcPO2 and LD probes were placed over the first metatarsal cleft and SBF recorded with the limb horizontal, dependant and elevated. Ankle to brachial pressure ratios (A:B) were also measured. Twelve patients with lower limb ischaemia, mean A:B ratio 0.5 +/- 0.21 (+/- S.D.) were compared with 21 asymptomatic controls, mean A:B ratio 1.2 +/- 0.15. In the controls, neither TcPO2 nor LD values changed significantly with limb position. Both flux and oxygen tension were significantly lower in ischaemic limbs in all positions; on lowering the ischaemic limb, flux unexpectedly rose to 23.5 +/- 17.7 V from a mean of 14 + 9.0 V (horizontal). Both TcPO2 and LD correlated well with A:B ratio in two positions: horizontal r (TcPO2) = 0.73, r(LD) = 0.57; elevated r(TcPO2) = 0.78, r(LD) = 0.68. Overall there was a highly significant correlation between LD and TcPO2 (r = 0.6, P less than 0.001, Student's test), but this was strongest in the elevated position (r = 0.87, P less than 0.001). LD and TcPO2 relate to A:B ratio and to each other, particularly in the stressed limb; in the well perfused limb, the poorer correlation suggests skin perfusion is not linearly related to tissue oxygen tension.
De Marchi, S; Zecchetto, S; Rigoni, A; Prior, M; Fondrieschi, L; Scuro, A; Rulfo, F; Arosio, E
2012-10-01
Chronic critical limb ischemia (CLI) is a severe condition of hypo-perfusion of lower limbs, which is associated with inflammation and a pro-coagulative state. It is a disease at high risk of amputation and cardiovascular death. Propionyl-L-carnitine (PLC) is efficacious in improving pain free walking distance in peripheral arterial disease with claudication; it also exerts favorable effects on the arterial wall and on endothelial function. The purpose of this study was to evaluate the effects of PLC on microcirculation, endothelial function and pain relief in patients affected by CLI not suitable for surgical intervention. We enrolled 48 patients with CLI. Patients were randomized into two groups: the first group was treated with PLC, the second was treated with saline solution. All of them underwent the following tests: laser Doppler flowmetry at the forefoot at rest and after ischemia, trans cutaneous oxygen partial pressure and carbon dioxide partial pressure at the forefoot at rest and after ischemia, endothelium dependent dilation of the brachial artery. All tests were repeated after treatments. Pain was assessed by visual analog pain scale. Endothelium dependent dilation increased after PLC (9.5 ± 3.2 vs 4.9 ± 1.4 %; p < 0.05). Post-ischemic peak flow with laser-Doppler flow increased after PLC. TcPO2 increased, while TcPCO2 decreased after PLC; CO2 production decreased after PLC. VAS showed a significant reduction in pain perception after active treatment. In CLI patients, PLC can improve microcirculation (post ischemic hyperemia, TcPO2 and TcPCO2 production). PLC also enhances endothelium dependent dilation and reduces analgesic consumption and pain perception.
Mahe, Guillaume; Liedl, David A; McCarter, Charlene; Shepherd, Roger; Gloviczki, Peter; McPhail, Ian R; Rooke, Thom W; Wennberg, Paul W
2014-04-01
This study was conducted to determine the sensitivity and specificity of laser Doppler flowmetry (LDF) measurements for digital obstructive arterial disease (DOAD) using angiography as the reference standard and to compare the accuracy of different classical tests used to assess DOAD. Diagnosis of vascular abnormalities at the digital level is challenging. Angiography is the gold standard for assessment of DOAD but is invasive and expensive to perform. We performed a retrospective analysis of consecutive patients referred at Mayo Clinic (Rochester, Minn) for upper extremity arterial assessment during a 27-month period. Finger-brachial index, skin blood flow (in arbitrary units [a.u.]), and skin temperature (in degrees Celsius) were recorded in each digit on the pulp at baseline and after a thermal challenge test (hand placed in a thermal box at 47.0°C for 15 minutes). Angiogram analysis was blinded and performed by a radiologist using a vascularization scale ranging from 0 (no vessel) to 4 (normal). The receiver operating characteristic curve was used to define a specific cutoff point to detect DOAD. Twenty-two patients had LDF measurements and complete angiograms. A total of 185 digits were analyzed because some patients had only analysis of one hand. The best area under the curve (AUC) was 0.98 (range, 0.94-0.99) for postwarming skin blood flow, with a cutoff point of ≤206 a.u. This AUC was statistically different from AUCs of all the other tests (P < .01). Sensitivity and specificity were 93% (95% confidence interval, 85%-97%) and 96% (95% confidence interval, 90%-99%), respectively. LDF combined with a thermal challenge is highly accurate, safe, and noninvasive means to detect DOAD. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Secchi, M E; Sulli, A; Pizzorni, C; Cutolo, M
2009-01-01
Systemic sclerosis (SSc) is characterized by altered microvascular structure and function. Nailfold videocapillaroscopy (NVC) is the tool to evaluate capillary morphological structure and laser-Doppler Blood flowmetry (LDF) can be used to estimate cutaneous blood flow of microvessels. The aim of this study was to investigate possible relationships between capillary morphology and blood flow in SSc. Twenty-seven SSc patients and 12 healthy subjects were enrolled. SSc microvascular involvement, as evaluated by NVC, was classified in three different patterns ("Early", "Active", "Late"). LDF analysis was performed at the II, III, IV, V hand fingers in both hands and both at cutaneous temperature and at 36 degrees C. Statistical evaluation was carried out by non-parametric procedures. Blood flow was found significantly lower in SSc patients when compared with healthy subjects (p<0.05). The heating of the probe to 36 degrees C induced a significant increase in peripheral blood flow in all subjects compared to baseline (p <0.05), however, the amount of variation was significantly lower in patients with SSc, compared with healthy controls (p <0.05). The SSc patients with NVC "Late" pattern, showed lower values of peripheral blood flow than patients with NVC "Active" or "Early" patterns (p<0.05). Moreover, a negative correlation between the tissue perfusion score and the progression of the SSc microangiopathy was observed, as well as between the tissue perfusion and the duration of the Raynaud's phenomenon (p <0.03). LDF can be employed to evaluate blood perfusion in the microvascular circulation in SSc patients. The blood flow changes observed with the LDF seem to correlate with the severity of microvascular damage in SSc as detected by NVC.
Hsiu, Hsin; Hsu, Wei-Chen; Hsu, Chia-Liang; Huang, Shih-Min
2011-01-01
We aimed to assess the effects of acupuncture by analyzing the frequency content of skin blood-flow signals simultaneously recorded at the Hegu acupoint and two nearby nonacupoints following acupuncture stimulation (AS). Laser Doppler flowmetry (LDF) signals were measured in male healthy volunteers in two groups of experiments: needling the Hegu acupoint (n = 13) and needling a nearby nonacupoint (control experiment; n = 10). Each experiment involved recording a 20 min baseline-data sequence and two sets of effects data recorded 0–20 and 50–70 min after stopping AS. Wavelet transform with Morlet mother wavelet was applied to the measured LDF signals. Needling the Hegu acupoint significantly increased the blood flow, significantly decreased the relative energy contribution at 0.02–0.06 Hz and significantly increased the relative energy contribution at 0.4–1.6 Hz at Hegu, but induced no significant changes at the nonacupoints. Also, needling a nearby nonacupoint had no effect in any band at any site. This is the first time that spectral analysis has been used to investigate the microcirculatory blood-flow responses induced by AS, and has revealed possible differences in sympathetic nerve activities between needling the Hegu acupoint and its nearby nonacupoint. One possible weakness of the present design is that different De-Qi feelings following AS could lead to nonblind experimental setup, which may bias the comparison between needling Hegu and its nearby nonacupoint. Our results suggest that the described noninvasive method can be used to evaluate sympathetic control of peripheral vascular activity, which might be useful for studying the therapeutic effects of AS. PMID:21804856
Hirata, K; Nagasaka, T; Noda, Y
1988-01-01
This study was made to see whether changes in blood flow through the capillaries and arteriovenous anastomoses (AVA's) of the human finger can be measured by noninvasive flowmetry. Total finger blood flow (FBF) was measured by venous occlusion plethysmography; blood flow was measured by a laser-Doppler flowmeter (ADVANCE, ALF-2100, Tokyo, Japan) using probes with optic fiber separations of 0.3 mm (LDF-0.3) and 0.7 mm (LDF-0.7). The maximum sensitivities for LDF-0.3 and LDF-0.7 were at depths of 0.8 and 1.2 mm from the tissue surface respectively. Two series of experiments were performed on separate days. In the first series the test hand was immersed in a water bath whose temperature (Tw) was 25 degrees C at an ambient temperature (Ta) of 25 degrees C. Tw was raised to 35 degrees C (local hand warming), which was then followed by an increase in Ta to 35 degrees C (whole body warming). FBF, LDF-0.3, and LDF-0.7 increased during these thermal stimulations. However, the relationship of FBF to LDF-0.3 showed two different regression lines. In contrast, the relationship of FBF to LDF-0.7 showed a single regression line. In the second series, with Ta at 35 degrees C, the test hand was immersed in a water bath at Tw 35 degrees C. Tw was then raised every 10 min by 2 degrees C steps from 35 to 41 degrees C. At Tw 39-41 degrees C, FBF and LDF-0.7 in the test hand were significantly decreased compared with those at Tw 35 degrees C.(ABSTRACT TRUNCATED AT 250 WORDS)
Dornseifer, Ulf; Kleeberger, Charlotte; Kargl, Lukas; Schönberger, Markus; Rohde, Daniel; Ninkovic, Milomir; Schilling, Arndt
2017-03-01
Background The current standard to gradually adapt the fragile perfusion in lower extremity free flaps to an upright posture is the dangling maneuver. This type of flap training neither fits the orthostatic target load of an upright posture, nor does it assist in mobilizing the patients effectively. In this study, we quantitatively analyzed training effects of an early and full mobilization on flap perfusion. Methods A total of 15 patients with gracilis flaps for distal lower extremity reconstruction were included. Flap training was performed daily by mobilizing the patients on a tilt table into a fully upright posture for 5 minutes between the third and fifth postop days (PODs). Changes in micro- and macrocirculation were analyzed by laser Doppler flowmetry, remission spectroscopy, and an implanted Doppler probe. Results All flaps healed without complications. Yet, in three patients, the increased orthostatic load required an adjustment of the training duration due to a critical blood flow. The others showed an increasing compensation in the microcirculation. When tilting the patients, blood flow and oxygen saturation dropped significantly less on POD5 than on POD3. Furthermore, a significant increase of the blood flow was noted after an initial decrease during the mobilization on all days. An increasing compensation in the macrocirculation could not be determined. Conclusion Full mobilization of patients with lower extremity free flaps can be performed safely under perfusion monitoring, already starting on POD3. Additionally, monitoring allows a consideration of the individual orthostatic competence and therefore, exploitation of the maximum mobilization potential. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Aleksandrin, Valery V; Ivanov, Alexander V; Virus, Edward D; Bulgakova, Polina O; Kubatiev, Aslan A
2018-04-03
The purpose of the present study was to investigate the use of laser Doppler flowmetry (LDF) signals coupled with spectral wavelet analysis to detect endothelial link dysfunction in the autoregulation of cerebral blood flow in the setting of hyperhomocysteinaemia (HHcy). Fifty-one rats were assigned to three groups (intact, control, and HHcy) according to the results of biochemical assays of homocysteine level in blood plasma. LDF signals on the rat brain were recorded by LAKK-02 device to measure the microcirculatory blood flow. The laser operating wavelength and output power density were1064 nm and 0.051 W/mm 2 , respectively. A Morlet mother wavelet transform was applied to the measured 8-min LDF signals, and periodic oscillations with five frequency intervals were identified (0.01-0.04 Hz, 0.04-0.15 Hz, 0.15-0.4 Hz, 0.4-2 Hz, and 2-5 Hz) corresponding to endothelial, neurogenic, myogenic, respiratory, and cardiac origins, respectively. In initial state, the amplitude of the oscillations decreased by 38% (P < 0.05) in the endothelial range in HHcy rats than in control rats. Cerebral autoregulation was challenged by hemorrhagic hypotension. The lower limit of autoregulation raised in a rat model of chronic HHcy (71.5 ± 0.7 mmHg in HHcy vs. 62.3 ± 0.5 mmHg in control). The data obtained indicate that the laser Doppler method and wavelet analysis may be successfully applied to detect the dysfunction of the endothelial link in cerebral vessel tone and to reveal the pathological shift of lower limit of autoregulation.
Hodges, Gary J; Kellogg, Dean L; Johnson, John M
2015-04-01
The vascular response to local skin cooling is dependent in part on a cold-induced translocation of α2C-receptors and an increased α-adrenoreceptor function. To discover whether β-adrenergic function might contribute, we examined whether β-receptor sensitivity to the β-agonist isoproterenol was affected by local skin temperature. In seven healthy volunteers, skin blood flow was measured from the forearm by laser-Doppler flowmetry and blood pressure was measured by finger photoplethysmography. Data were expressed as cutaneous vascular conductance (CVC; laser-Doppler flux/mean arterial blood pressure). Pharmacological agents were administered via intradermal microdialysis. We prepared four skin sites: one site was maintained at a thermoneutral temperature of 34°C (32 ± 10%CVCmax) one site was heated to 39°C (38 ± 11%CVCmax); and two sites were cooled, one to 29°C (22 ± 7%CVCmax) and the other 24°C (16 ± 4%CVCmax). After 20 min at these temperatures to allow stabilization of skin blood flow, isoproterenol was perfused in concentrations of 10, 30, 100, and 300 μM. Each concentration was perfused for 15 min. Relative to the CVC responses to isoproterenol at the thermoneutral skin temperature (34°C) (+21 ± 10%max), low skin temperatures reduced (at 29°C) (+17 ± 6%max) or abolished (at 24°C) (+1 ± 5%max) the vasodilator response, and warm (39°C) skin temperatures enhanced the vasodilator response (+40 ± 9%max) to isoproterenol. These data indicate that β-adrenergic function was influenced by local skin temperature. This finding raises the possibility that a part of the vasoconstrictor response to direct skin cooling could include reduced background β-receptor mediated vasodilation. Copyright © 2015 the American Physiological Society.
Long-term repetitive sodium lauryl sulfate-induced irritation of the skin: an in vivo study.
Branco, Nara; Lee, Ivy; Zhai, Hongbo; Maibach, Howard I
2005-11-01
Skin may adapt to topical irritants through accommodation. This study focuses on long-term exposure to irritants and attempts to demonstrate accommodation. Sodium lauryl sulfate (SLS) induced irritant contact dermatitis at 3 concentrations (0.025% to 0.075%). Distilled water, acetone and an empty chamber served as controls. Experimental compounds were applied to forearms of 7 healthy volunteers for 24 hr before replacing by a fresh chamber for 6 non-consecutive weeks over 103 days. Possible accommodation was quantified by visual scoring (erythema and dryness) and by bioengineering parameters: transepidermal water loss (TEWL), capacitance, chromametry and laser Doppler flowmetry (LDF). Significant erythema, dryness, elevated TEWL, skin colour reflectance and LDF values occurred during the exposure periods. Upon repeat exposure, an immediate and augmented response in erythema, TEWL, skin colour reflectance and LDF developed. However, irritant skin changes were not sustained. Irritation parameters return to baseline after cessation of exposure. There was no evidence of sustained irritation or accommodation after the last exposure. Study findings do not document sustained accommodation or adaptive hyposensitivity after long-term repetitive irritant exposure under these test conditions. Alternative models should be developed to prove or disprove the accommodation hypothesis.
NASA Astrophysics Data System (ADS)
Battecha, Kadria H.; Atya, Azza M.
2011-09-01
Reduced microcirculation is a morbid element of neuropathy and one of the most common complications of uncontrolled diabetes. Many physical modalities have gained a considerable attention for enhancing cutaneous microcirculation in diabetic patients and prevent its serious complications. Accordingly, the present study was conducted to compare between the effect of low intensity laser therapy (LILT) and transcutaneous electrical nerve stimulation (TENS) on microcirculation in diabetic neuropathy. Thirty diabetic polyneuropathic patients ranged in age from 45-60 years participated in this study. They were randomly divided into two groups of equal number; patients in group (A) received LILT on plantar surface of foot with a dose of 3 J/cm2 and wavelength (904 nm), while those in group (B) received TENS on lower leg for 30 minutes with frequency (2 HZ). Treatment was conducted 3 times/week for 6 weeks. The cutaneous microcirculation was evaluated by Laser Doppler flowmetry at the baseline and at the end of treatment. Results revealed that group (A) showed statistically significant increase in the cutaneous microcirculation compared with group (B). So, it was concluded that LILT has to be more efficient than TENS in increasing cutaneous microcirculation in patients with diabetic neuropathy.
The effects of angiotensin II on blood perfusion in the rat renal papilla
Walker, L L; Rajaratne, A A J; Blair-West, J R; Harris, P J
1999-01-01
Systemic infusion of angiotensin II (AII) increased papillary blood perfusion (PBP) measured by laser-Doppler flowmetry in rats, aged about 5 weeks. The mechanisms involved in this response were determined by infusion of AII in the presence of systemic doses of losartan (a type 1 AII receptor antagonist), HOE-140 (a bradykinin B2 receptor antagonist), and an inhibitor of NO production - Nω -nitro-L-arginine (NOLA). Mean arterial blood pressure (MAP) and PBP increased in a dose-dependent manner in response to intravenous infusions of AII. Infusion of losartan abolished these responses to AII but HOE-140 was without effect. Infusion of NOLA abolished the increase in PBP but did not affect the pressor response to AII. Systemic infusion of sodium nitroprusside restored the response to AII in experiments with NOLA infusion. The results indicate that the increase in PBP caused by AII is mediated via angiotensin AT1 receptors and does not involve bradykinin B2 receptors. The AII-induced increase in PBP is dependent upon the presence of NO, thus providing a mechanism for maintenance of papillary perfusion in the face of generalized renal vasoconstriction due to AII. PMID:10432357
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouet, T.; Schmitt, M.; Desuzinges, C.
1990-11-01
Hyperemia associated with an inflammatory response has been investigated in rats, by using four different experimental models, i.e., positive and negative polymer implants from the pharmacopea, operative control, and abscess induced by turpentine oil. 133Xenon clearance, infrared thermography and Laser Doppler Flowmetry (LDF) were used to monitor the subcutaneous local hemodynamic changes from 1 to 40 postoperative days. LDF proved to be a sensitive, reproducible method, able to discriminate positive from negative implants already at the 3rd postoperative day and up to 40 days. This increased local blood flow was also visualized at the site of positive implants at themore » 14th and 21st postoperative days by means of 133Xe Clearance. Additional information obtained by infrared thermography allowed discrimination between positive implants and control sites but only at the very early stage (1 to 3 days). The significance of the different data collected by the three techniques was correlated with histological events occurring at the different implant sites. LDF may therefore represent a useful technique for noninvasive semiquantitative assessment of tissue response to biomaterials.« less
NASA Astrophysics Data System (ADS)
Dremin, Viktor V.; Zherebtsov, Evgeny A.; Sidorov, Victor V.; Krupatkin, Alexander I.; Makovik, Irina N.; Zherebtsova, Angelina I.; Zharkikh, Elena V.; Potapova, Elena V.; Dunaev, Andrey V.; Doronin, Alexander A.; Bykov, Alexander V.; Rafailov, Ilya E.; Litvinova, Karina S.; Sokolovski, Sergei G.; Rafailov, Edik U.
2017-08-01
According to the International Diabetes Federation, the challenge of early stage diagnosis and treatment effectiveness monitoring in diabetes is currently one of the highest priorities in modern healthcare. The potential of combined measurements of skin fluorescence and blood perfusion by the laser Doppler flowmetry method in diagnostics of low limb diabetes complications was evaluated. Using Monte Carlo probabilistic modeling, the diagnostic volume and depth of the diagnosis were evaluated. The experimental study involved 76 patients with type 2 diabetes mellitus. These patients were divided into two groups depending on the degree of complications. The control group consisted of 48 healthy volunteers. The local thermal stimulation was selected as a stimulus on the blood microcirculation system. The experimental studies have shown that diabetic patients have elevated values of normalized fluorescence amplitudes, as well as a lower perfusion response to local heating. In the group of people with diabetes with trophic ulcers, these parameters also significantly differ from the control and diabetes only groups. Thus, the intensity of skin fluorescence and level of tissue blood perfusion can act as markers for various degrees of complications from the beginning of diabetes to the formation of trophic ulcers.
Peripheral vascular responses to heat stress after hindlimb suspension
NASA Technical Reports Server (NTRS)
Looft-Wilson, Robin C.; Gisolfi, Carl V.
2002-01-01
PURPOSE: The purpose of this study was to determine whether hindlimb suspension (which simulates the effects of microgravity) results in impaired hemodynamic responses to heat stress or alterations in mesenteric small artery sympathetic nerve innervation. METHODS: Over 28 d, 16 male Sprague-Dawley rats were hindlimb-suspended, and 13 control rats were housed in the same type of cage. After the treatment, mean arterial pressure (MAP), colonic temperature (Tcol), and superior mesenteric and iliac artery resistances (using Doppler flowmetry) were measured during heat stress [exposure to 42 degrees C until the endpoint of 80 mm Hg blood pressure was reached (75 +/- 9 min); endpoint Tcore = 43.6 +/- 0.2] while rats were anesthetized (sodium pentobarbital, 50 mg x kg(-1) BW). RESULTS: Hindlimb-suspended and control rats exhibited similar increases in Tcol, MAP, and superior mesenteric artery resistance, and similar decreases in iliac resistance during heat stress (endpoint was a fall in MAP below 80 mm Hg). Tyrosine hydroxylase immunostaining indicated similar sympathetic nerve innervation in small mesenteric arteries from both groups. CONCLUSION: Hindlimb suspension does not alter the hemodynamic or thermoregulatory responses to heat stress in the anesthetized rat or mesenteric sympathetic nerve innervation, suggesting that this sympathetic pathway is intact.
[Investigation of postconditioning in intestinal ischemia-reperfusion experimental models].
Rosero, Olivér; Onody, Péter; Stangl, Rita; Hegedus, Viktor; Lotz, Gábor; Blázovics, Anna; Kupcsulik, Péter; Szijártó, Attila
2011-02-01
The ischemic-reperfusion injury of the intestine, which occurs as a consequence of circulatory redistribution or occlusion of the superior mesenteric artery, is associated with high mortality rates. Postconditioning may reduce ischemic-reperfusion damage in such cases. Effects of this new surgical method were investigated in rats. Male Wistar rats underwent 60 minutes of superior mesenteric artery occlusion in four groups: sham-operated, control and two postconditioned groups with different algorithms. Postconditioning was performed immediately at the beginning of reperfusion, by repetitive cycles of reperfusion and reocclusion. 3 cycles of 1 minute and 6 cycles of 10 seconds were applied according to groups. Intestinal microcirculation was followed by laser Doppler flowmetry. Blood and tissue samples were taken after 60 minutes of reperfusion. Histological analayses of the small intestine, measurement of serum necroenzyme levels and IL-6, mesenterial venous blood gas analyses were preformed and antioxidant state of the mucosa was investigated. The microcirculation during the reperfusion showed significant improvement in both postconditioned groups. Histological damage, necroenzyme and IL-6 levels were significantly reduced, while antioxidant state was improved in the postconditioned groups. Postconditioning was capable of increasing the guts chance to survive ischemic-reperfusion injury caused by superior mesenteric artery occlusion.
Evaluation of a high framerate multi-exposure laser speckle contrast imaging setup
NASA Astrophysics Data System (ADS)
Hultman, Martin; Fredriksson, Ingemar; Strömberg, Tomas; Larsson, Marcus
2018-02-01
We present a first evaluation of a new multi-exposure laser speckle contrast imaging (MELSCI) system for assessing spatial variations in the microcirculatory perfusion. The MELSCI system is based on a 1000 frames per second 1-megapixel camera connected to a field programmable gate arrays (FPGA) capable of producing MELSCI data in realtime. The imaging system is evaluated against a single point laser Doppler flowmetry (LDF) system during occlusionrelease provocations of the arm in five subjects. Perfusion is calculated from MELSCI data using current state-of-the-art inverse models. The analysis displayed a good agreement between measured and modeled data, with an average error below 6%. This strongly indicates that the applied model is capable of accurately describing the MELSCI data and that the acquired data is of high quality. Comparing readings from the occlusion-release provocation showed that the MELSCI perfusion was significantly correlated (R=0.83) to the single point LDF perfusion, clearly outperforming perfusion estimations based on a single exposure time. We conclude that the MELSCI system provides blood flow images of enhanced quality, taking us one step closer to a system that accurately can monitor dynamic changes in skin perfusion over a large area in real-time.
Spatio-temporal dynamics of perfusion and oximetry during ictal discharges in the rat neocortex
Zhao, Mingrui; Ma, Hongtao; Suh, Minah; Schwartz, Theodore H.
2009-01-01
Epileptic events elicit a large focal increase in cerebral blood flow (CBF) to perfuse metabolically active neurons in the focus. Conflicting data exists, however, on whether hemoglobin saturation increases or decreases in the focus and surrounding cortex, and whether CBF increases globally or is decreased in adjacent areas. How these hemodynamic events correlate with actual changes in tissue oxygenation is also not known. Using laser Doppler flowmetry, oxygen microsensors and intrinsic optical imaging spectroscopy, we demonstrate that the dip in hemoglobin in the focus correlates with a profound but temporary decrease in tissue oxygenation in spite of a large increase in cerebral blood flow (CBF). Furthermore, CBF simultaneously decreases in the cortex immediately adjacent to the focus. These events are then replaced with a longer duration, less focal increase in CBF, CBV and hyperoxygenation, the duration of which correlates with the duration of the seizure. These findings raise the question of whether transient focal hypoxia and vascular steal might contribute to progressive deleterious effects of chronic epilepsy on the adult and developing brain. Possible mechanisms based on recent astrocyte-based models of neurovascular coupling are discussed. Implications for functional magnetic resonance imaging of epileptic events are discussed. PMID:19261877
Improvement in Retinal Capillary Rarefaction After Valsartan Treatment in Hypertensive Patients.
Jumar, Agnes; Harazny, Joanna M; Ott, Christian; Kistner, Iris; Friedrich, Stefanie; Schmieder, Roland E
2016-11-01
Decreased capillary density influences vascular resistance and perfusion. The authors aimed to investigate the influence of the renin-angiotensin receptor blocker valsartan on retinal capillary rarefaction in hypertensive patients. Retinal vascular parameters were measured noninvasively and in vivo by scanning laser Doppler flowmetry before and after 4 weeks of treatment with valsartan in 95 patients with hypertension stage 1 or 2 and compared with 55 healthy individuals. Retinal capillary rarefaction was determined with the parameters intercapillary distance (ICD) and capillary area (CapA). In hypertensive patients, ICD decreased (23.4±5.5 μm vs 21.5±5.6 μm, P<.001) and CapA increased (1564±621 vs 1776±795, P=.001) after valsartan treatment compared with baseline. Compared with healthy normotensive controls (ICD 20.2±4.2 μm, CapA 1821±652), untreated hypertensive patients showed greater ICD (P<.001) and smaller CapA (P=.019), whereas treated hypertensive patients showed no difference in ICD (P=.126) and CapA (P=.728). Therapy with valsartan for 4 weeks diminished capillary rarefaction in hypertensive patients. © 2016 Wiley Periodicals, Inc.
Polska, Elzbieta; Luksch, Alexandra; Schering, Joanne; Frank, Barbara; Imhof, Andrea; Fuchsjäger-Mayrl, Gabriele; Wolzt, Michael; Schmetterer, Leopold
2003-01-01
Recent studies indicate that the human choroid has a considerable capacity to keep blood flow constant despite exercise-induced increases in perfusion pressure. The mechanisms underlying this vasoconstrictor response remain unclear. We hypothesized that pharmacological modulation of the autonomic nervous system may alter the choroidal pressure/flow relationship during squatting. To test this hypothesis, we performed a randomized, double-masked, placebo-controlled, three-way crossover study in 15 healthy male volunteers. Subjects received, on different study days, intravenous infusions of the beta-adrenoceptor antagonist propranolol, the muscarinic receptor antagonist atropine, or placebo. During these infusions, subjects performed squatting for 6 min. Choroidal blood flow was assessed with laser Doppler flowmetry and ocular perfusion pressure (OPP) was calculated from mean arterial pressure and intraocular pressure. As expected, propranolol reduced basal pulse rate, whereas atropine increased pulse rate, indicating that the drugs were administered at systemically effective doses. None of the drugs altered the choroidal pressure/flow relationship during isometric exercise. These data indicate that the regulatory vasoconstrictor capacity of the choroid during exercise is not affected by systemic blockade of beta-adrenoceptors or muscarinic receptors.
Physiological Responses to Thermal Stress and Exercise
NASA Astrophysics Data System (ADS)
Iyota, Hiroyuki; Ohya, Akira; Yamagata, Junko; Suzuki, Takashi; Miyagawa, Toshiaki; Kawabata, Takashi
The simple and noninvasive measuring methods of bioinstrumentation in humans is required for optimization of air conditioning and management of thermal environments, taking into consideration the individual specificity of the human body as well as the stress conditions affecting each. Changes in human blood circulation were induced with environmental factors such as heat, cold, exercise, mental stress, and so on. In this study, the physiological responses of human body to heat stress and exercise were investigated in the initial phase of the developmental research. We measured the body core and skin temperatures, skin blood flow, and pulse wave as the indices of the adaptation of the cardiovascular system. A laser Doppler skin blood flowmetry using an optical-sensor with a small portable data logger was employed for the measurement. These results reveal the heat-stress and exercise-induced circulatory responses, which are under the control of the sympathetic nerve system. Furthermore, it was suggested that the activity of the sympathetic nervous system could be evaluated from the signals of the pulse wave included in the signals derived from skin blood flow by means of heart rate variability assessments and detecting peak heights of velocity-plethysmogram.
Nadort, Annemarie; Woolthuis, Rutger G.; van Leeuwen, Ton G.; Faber, Dirk J.
2013-01-01
We present integrated Laser Speckle Contrast Imaging (LSCI) and Sidestream Dark Field (SDF) flowmetry to provide real-time, non-invasive and quantitative measurements of speckle decorrelation times related to microcirculatory flow. Using a multi exposure acquisition scheme, precise speckle decorrelation times were obtained. Applying SDF-LSCI in vitro and in vivo allows direct comparison between speckle contrast decorrelation and flow velocities, while imaging the phantom and microcirculation architecture. This resulted in a novel analysis approach that distinguishes decorrelation due to flow from other additive decorrelation sources. PMID:24298399
Detection and capture of single circulating melanoma cells using photoacoustic flowmetry
NASA Astrophysics Data System (ADS)
O'Brien, Christine; Mosley, Jeffrey; Goldschmidt, Benjamin S.; Viator, John A.
2010-02-01
Photoacoustic flowmetry has been used to detect single circulating melanoma cells in vitro. Circulating melanoma cells are those cells that travel in the blood and lymph systems to create secondary tumors and are the hallmark of metastasis. This technique involves taking blood samples from patients, separating the white blood and melanoma cells from whole blood and irradiating them with a pulsed laser in a flowmetry set up. Rapid, visible wavelength laser pulses on the order of 5 ns can induce photoacoustic waves in melanoma cells due to their melanin content, while surrounding white blood cells remain acoustically passive. We have developed a system that identifies rare melanoma cells and captures them in 50 microliter volumes using suction applied near the photoacoustic detection chamber. The 50 microliter sample is then diluted and the experiment is repeated using the new sample until only a melanoma cell remains. We have tested this system on dyed microspheres ranging in size from 300 to 500 microns. Capture of circulating melanoma cells may provide the opportunity to study metastatic cells for basic understanding of the spread of cancer and to optimize patient specific therapies.
Löffler, H; Happle, R
2003-01-01
The cutaneous reaction to detergents follows distinct kinetic rules: the duration of application and the irritant concentration are of major importance. The aim of this study was to evaluate the differences in kinetics of skin reaction between the standard irritant sodium lauryl sulfate (SLS), and 2 modern detergents: sodium laureth sulfate (SLES) and alkyl polyglucoside (APG). We performed patch testing with SLS and SLES (or APG) at different concentrations (0.125, 0.25, 0.5, 1.0 and 2.0%) and with different exposure times (6, 12 and 24 h). Evaluation was conducted by measurement of transepidermal water loss (TEWL) and laser Doppler flowmetry (LD) 24 h, 7 and 10 days after patch removal. We found a pronounced reaction to SLS, and a far milder one to SLES. Even at the highest concentration the skin reaction to APG was hard to detect. During the regeneration period (day 3-10) SLS showed even at day 10 an increased TEWL at all concentrations tested. The irritation due to SLES was convincingly detectable only up to day 7, whereas the APG-tested skin areas showed no significant reaction even at day 3. These results demonstrate the improvement in reduction of skin irritation achieved by development of novel detergents.
Effect of postprandial thermogenesis on the cutaneous vasodilatory response during exercise.
Hayashi, Keiji; Ito, Nozomi; Ichikawa, Yoko; Suzuki, Yuichi
2014-08-01
To examine the effect of postprandial thermogenesis on the cutaneous vasodilatory response, 10 healthy male subjects exercised for 30 min on a cycle ergometer at 50% of peak oxygen uptake, with and without food intake. Mean skin temperature, mean body temperature (Tb), heart rate, oxygen uptake, carbon dioxide elimination, and respiratory quotient were all significantly higher at baseline in the session with food intake than in the session without food intake. To evaluate the cutaneous vasodilatory response, relative laser Doppler flowmetry values were plotted against esophageal temperature (Tes) and Tb. Regression analysis revealed that the [Formula: see text] threshold for cutaneous vasodilation tended to be higher with food intake than without it, but there were no significant differences in the sensitivity. To clarify the effect of postprandial thermogenesis on the threshold for cutaneous vasodilation, the between-session difference in the Tes threshold and the Tb threshold were plotted against the between-session difference in baseline Tes and baseline Tb, respectively. Linear regression analysis of the resultant plot showed significant positive linear relationships (Tes: r = 0.85, P < 0.01; Tb: r = 0.67, P < 0.05). These results suggest that postprandial thermogenesis increases baseline body temperature, which raises the body temperature threshold for cutaneous vasodilation during exercise.
Caffeine does not affect susceptibility to cortical spreading depolarization in mice.
Yalcin, Nilufer; Chen, Shih-Pin; Yu, Esther S; Liu, Tzu-Ting; Yen, Jiin-Cherng; Atalay, Yahya B; Qin, Tao; Celik, Furkan; van den Maagdenberg, Arn Mjm; Moskowitz, Michael A; Ayata, Cenk; Eikermann-Haerter, Katharina
2018-01-01
Several factors that modulate migraine, a common primary headache disorder, also affect susceptibility to cortical spreading depolarization (CSD). CSD is a wave of neuronal and glial depolarization and thought to underlie the migraine aura and possibly headache. Here, we tested whether caffeine, known to alleviate or trigger headache after acute exposure or chronic use/withdrawal, respectively, modulates CSD. We injected C57BL/6J mice with caffeine (30, 60, or 120 mg/kg; i.p.) once (acute) or twice per day for one or two weeks (chronic). Susceptibility to CSD was evaluated by measuring the electrical CSD threshold and by assessing KCl-induced CSD. Simultaneous laser Doppler flowmetry was used to assess CSD-induced cortical blood flow changes. Recordings were performed 15 min after caffeine/vehicle administration, or 24 h after the last dose of chronic caffeine in the withdrawal group. The latter paradigm was also tested in mice carrying the familial hemiplegic migraine type 1 R192Q missense mutation, considered a valid migraine model. Neither acute/chronic administration nor withdrawal of caffeine affected CSD susceptibility or related cortical blood flow changes, either in WT or R192Q mice. Hence, adverse or beneficial effects of caffeine on headache seem unrelated to CSD pathophysiology, consistent with the non-migrainous clinical presentation of caffeine-related headache.
Möckesch, Berenike; Connes, Philippe; Charlot, Keyne; Skinner, Sarah; Hardy-Dessources, Marie-Dominique; Romana, Marc; Jumet, Stéphane; Petras, Marie; Divialle-Doumdo, Lydia; Martin, Cyril; Tressières, Benoît; Tarer, Vanessa; Hue, Olivier; Etienne-Julan, Maryse; Antoine, Sophie; Pialoux, Vincent
2017-08-01
Oxidative stress and haemolysis-associated nitric oxide (NO) depletion plays a crucial role in the development of vasculopathy in sickle cell anaemia (SS). However it remains unknown whether oxidative stress and haemolysis levels influence vascular function in patients with sickle haemoglobin C disease (SC). Microvascular response to heat (using Laser Doppler flowmetry on finger), oxidative stress biomarkers, NO metabolites, endothelin-1 and haematological parameters were compared between patients with SS and SC. Vascular function, oxidative and nitrosative markers were also measured in healthy (AA) children. SS and SC had increased plasma advanced oxidation protein products (AOPP), malondialdehyde, plasma antioxidant activities and NO end products, compared to AA. SC had lower catalase activity compared to AA and SS. Haemolytic rate, glutathione peroxidase and nitrotyrosine concentrations were significantly increased in children with SS compared to SC and AA. SS and SC had impaired microvascular reactivity compared to AA. In SS, the plateau phase of the response to local thermal heating was negatively associated with nitrotyrosine and AOPP. No association between vascular function parameters and oxidative stress markers was observed in SC. Mild haemolysis in SC, compared to SS, may limit oxidative and nitrosative stress and could explain the better preserved microvascular function in this group. © 2017 John Wiley & Sons Ltd.
Fichter, Andreas M; Ritschl, Lucas M; Robitzky, Luisa K; Wagenpfeil, Stefan; Mitchell, David A; Wolff, Klaus-Dietrich; Mücke, Thomas
2016-10-21
The effects of antithrombotic drugs on random and free flap survival have been investigated in the past, but the experimental and clinical results are not in agreement. A perforator-based critical ischaemia model was used to evaluate the effects of different perioperatively administered pharmaceutical agents on tissue ischaemia and to assess the potential additional haemorheological or vasodilative effects of antithrombotics on flap microcirculation. Combined laser Doppler flowmetry and remission spectroscopy revealed an increase in certain microcirculation parameters in most groups in comparison with saline controls, and these changes correlated with flap survival. Clopidogrel and hirudin significantly improved the amount of viable flap tissue in comparison with controls, while unfractioned heparin had a negative effect on flap survival. Low molecular weight heparin, aspirin, pentoxifylline, and hydroxyethyl starch had no impact on the amount of viable flap tissue. A higher complication rate was observed in all experimental groups, but only clopidogrel had a negative impact on the flap viability. Our results add to the body of evidence supporting the conclusion that perioperative antithrombotic treatment improves flap survival. Clopidogrel and hirudin are effective pharmacological agents that significantly increased the viability of perforator-based skin flaps in rats, but at a higher risk of postoperative bleeding.
Mechanisms of gastroprotection by transdermal nitroglycerin in the rat
Calatayud, Sara; Sanz, María-Jesús; Canet, Amparo; Bello, Regina; de Rojas, Francisco Díaz; Esplugues, Juan V
1999-01-01
Nitric oxide (NO) donors prevent experimentally-induced gastric mucosal damage, but their clinical utility is limited by short duration of action or unsuitability of the pharmaceutical form employed. This study analyses the gastroprotection elicited by a clinically used mode of continuous administration of an NO donor, namely the nitroglycerin patch. Application to rats of a transdermal patch that releases doses of nitroglycerin comparable to those used in man (40, 80, 160 and 400 ng min−1 rat−1) reduced gastric damage induced by indomethacin (25 mg kg−1, p.o. or s.c.). The nitroglycerin patch (160 ng min−1 rat−1) also diminished damage by oral administration (1 ml) of acidified bile salts (100 mg kg−1 taurocholic acid in 150 mM HCl) or 50% ethanol. Transdermal nitroglycerin (160 ng min−1 rat−1) did not influence basal gastric blood flow, as measured by lasser-doppler flowmetry, but prevented its reduction by indomethacin. Transdermal nitroglycerin (160 ng min−1 rat−1) prevented in vivo leukocyte rolling and adherence in the rat mesentery microvessels superfused with indomethacin, as evaluated by intravital microscopy. The transdermal nitroglycerin patch protects the gastric mucosa from damage by mechanisms that involve maintenance of mucosal blood flow and reduction of leukocyte-endothelial cell interaction. PMID:10455256
McConnell, Douglas J.; Afzal, Aqeela; Mocco, J
2011-01-01
Stroke is the third leading cause of death and the leading cause of disability in the world, with an estimated cost of near $70 billion in the United States in 20091,2. The intraluminal middle cerebral artery occlusion (MCAO) model was developed by Koizumi4 in 1986 to simulate this impactful human pathology in the rat. A modification of the MCAO method was later presented by Longa3. Both techniques have been widely used to identify molecular mechanisms of brain injury resulting from ischemic stroke and potential therapeutic modalities5. This relatively noninvasive method in rats has been extended to use in mice to take advantage of transgenic and knockout strains6,7. To model focal cerebral ischemia, an intraluminal suture is advanced via the internal carotid artery to occlude the base of the MCA. Retracting the suture after a specified period of time mimics spontaneous reperfusion, but the suture can also be permanently retained. This video will be demonstrating the two major approaches for performing intraluminal MCAO procedure in mice in a stepwise fashion, as well as providing insights for potential drawbacks and pitfalls. The ischemic brain tissue will subsequently be stained by 2,3,5-triphenyltetrazolium chloride (TTC) to evaluate the extent of cerebral infarction8. PMID:21587164
Santos, Edgar; Schöll, Michael; Kunzmann, Kevin; Stock, Christian; Silos, Humberto; Unterberg, Andreas W; Sakowitz, Oliver W
2016-01-01
Spreading depolarization (SD) generates significant alterations in cerebral haemodynamics, which can have detrimental consequences on brain function and integrity. Ketamine has shown an important capacity to modulate SD; however, its impact on SD haemodynamic response is incompletely understood. We investigated the effect of two therapeutic ketamine dosages, a low-dose of 2 mg/kg/h and a high-dose of 4 mg/kg/h, on the haemodynamic response to SD in the gyrencephalic swine brain. Cerebral blood volume, pial arterial diameter and cerebral blood flow were assessed through intrinsic optical signal imaging and laser-Doppler flowmetry. Our findings indicate that frequent SDs caused a persistent increase in the baseline pial arterial diameter, which can lead to a diminished capacity to further dilate. Ketamine infused at a low-dose reduced the hyperemic/vasodilative response to SD; however, it did not alter the subsequent oligemic/vasoconstrictive response. This low-dose did not prevent the baseline diameter increase and the diminished dilative capacity. Only infusion of ketamine at a high-dose suppressed SD and the coupled haemodynamic response. Therefore, the haemodynamic response to SD can be modulated by continuous infusion of ketamine. However, its use in pathological models needs to be explored to corroborate its possible clinical benefit. PMID:27126324
Sánchez-Porras, Renán; Santos, Edgar; Schöll, Michael; Kunzmann, Kevin; Stock, Christian; Silos, Humberto; Unterberg, Andreas W; Sakowitz, Oliver W
2017-05-01
Spreading depolarization (SD) generates significant alterations in cerebral haemodynamics, which can have detrimental consequences on brain function and integrity. Ketamine has shown an important capacity to modulate SD; however, its impact on SD haemodynamic response is incompletely understood. We investigated the effect of two therapeutic ketamine dosages, a low-dose of 2 mg/kg/h and a high-dose of 4 mg/kg/h, on the haemodynamic response to SD in the gyrencephalic swine brain. Cerebral blood volume, pial arterial diameter and cerebral blood flow were assessed through intrinsic optical signal imaging and laser-Doppler flowmetry. Our findings indicate that frequent SDs caused a persistent increase in the baseline pial arterial diameter, which can lead to a diminished capacity to further dilate. Ketamine infused at a low-dose reduced the hyperemic/vasodilative response to SD; however, it did not alter the subsequent oligemic/vasoconstrictive response. This low-dose did not prevent the baseline diameter increase and the diminished dilative capacity. Only infusion of ketamine at a high-dose suppressed SD and the coupled haemodynamic response. Therefore, the haemodynamic response to SD can be modulated by continuous infusion of ketamine. However, its use in pathological models needs to be explored to corroborate its possible clinical benefit.
Optical monitoring of cerebral microcirculation in neurointensive care.
Rejmstad, Peter; Haj-Hosseini, Neda; Åneman, Oscar; Wårdell, Karin
2017-12-08
Continuous optical monitoring of local cerebral microcirculation could benefit neurointensive care patients treated for subarachnoid hemorrhage (SAH). The aim of the study was to evaluate laser Doppler flowmetry (LDF) and diffuse reflectance spectroscopy (DRS) for long-term monitoring of brain microcirculation and oxygen saturation (SO 2 ) in the neurointensive care unit (NICU). A fiber optic probe was designed for intraparenchymal use and connected to LDF and DRS for assessment of the local blood flow (perfusion and tissue reflectance (TLI)) and SO 2 in the brain. The optically monitored parameters were compared with conventional NICU monitors and Xe-CT. The LDF signals were low with median and 25 to 75% interquartiles of perfusion = 70 (59 to 83) a.u. and TLI = 2.0 (1.0 to 2.4) a.u. and showed correlation with the NICU monitors in terms of heart rate. Median and interquartiles of SO 2 were 17.4 (15.7 to 19.8) %. The lack of correlation between local perfusion and cerebral perfusion pressure indicated intact cerebral autoregulation. The systems were capable of monitoring both local perfusion and SO 2 with stable signals in the NICU over 4 days. Further clinical studies are required to evaluate the optical systems' potential for assessing the onset of secondary brain injury.
Ministrini, Stefano; Fattori, Chiara; Ricci, Maria Anastasia; Bianconi, Vanessa; Paltriccia, Rita; Boni, Marcello; Paganelli, Maria Teresa; Vaudo, Gaetano; Lupattelli, Graziana; Pasqualini, Leonella
2018-05-12
Microvascular dysfunction is a potential factor explaining the association of obesity, insulin resistance, and vascular damage in morbidly obese subjects. The purpose of the study was to evaluate possible determinants of microcirculatory improvement 1 year after laparoscopic sleeve gastrectomy (LSG) intervention. Thirty-seven morbidly obese subjects eligible for bariatric surgery were included in the study. Post-occlusive reactive hyperemia (PORH) of the forearm skin was measured as area of hyperemia (AH) by laser-Doppler flowmetry before LSG and after a 1-year follow-up. After intervention, we observed a significant reduction in BMI, HOMA index, HbA1c, and a significant increase of AH in all patients after surgery; this variation was significant only in those patients having insulin resistance or prediabetes/diabetes. Although significant correlation between the increase of AH and the reduction of both BMI, HOMA index, and HbA1c was observed, BMI was the only independent predictor of AH variation after LSG at the linear regression analysis. Our study shows that LSG intervention is correlated with a significant improvement in the microvascular function of morbidly obese subjects; this improvement seems to be related to the baseline degree of insulin-resistance and to the retrieval of insulin-sensitivity post-intervention.
Aging-associated sensory neuropathy alters pressure-induced vasodilation in humans.
Fromy, Bérengère; Sigaudo-Roussel, Dominique; Gaubert-Dahan, Marie-Line; Rousseau, Pascal; Abraham, Pierre; Benzoni, Daniel; Berrut, Gilles; Saumet, Jean Louis
2010-03-01
Healthy skin is protected from pressure-induced ischemic damage because of the presence of pressure-induced vasodilation (PIV). PIV relies on small sensory nerve fibers and endothelial function. Since aging alters both nervous and vascular functions, we hypothesized that PIV is altered with aging. We compared PIV in non-neuropathic and neuropathic older subjects (60-75 years) with that of young subjects (20-35 years). Laser Doppler flowmetry was used to evaluate the cutaneous responses to local pressure application, acetylcholine, and local heating. Quantitative sensory tests were used to evaluate sensory-nerve-fiber function. The non-neuropathic older subjects had an impaired PIV (12+/-7% increase in blood flow with pressure) compared with young subjects (62+/-4%, P<0.001). In the presence of peripheral neuropathy, the older subjects were totally deprived of PIV, leading to early pressure-induced cutaneous ischemia (-31+/-10%, P<0.001). This inability of the skin to adapt to localized pressure in older subjects is related to the severity of the sensory-fiber dysfunction rather than to endothelial dysfunction, which was comparable between the non-neuropathic (141+/-19% increased blood flow with acetylcholine, P<0.05) and neuropathic older subjects (145+/-28% increase, P<0.05) compared with young subjects (234+/-25% increase).
NASA Astrophysics Data System (ADS)
Fredriksson, Ingemar; Saager, Rolf B.; Durkin, Anthony J.; Strömberg, Tomas
2017-11-01
A fiber-optic probe-based instrument, designed for assessment of parameters related to microcirculation, red blood cell tissue fraction (fRBC), oxygen saturation (S), and speed resolved perfusion, has been evaluated using state-of-the-art tissue phantoms. The probe integrates diffuse reflectance spectroscopy (DRS) at two source-detector separations and laser Doppler flowmetry, using an inverse Monte Carlo method for identifying the parameters of a multilayered tissue model. Here, we characterize the accuracy of the DRS aspect of the instrument using (1) liquid blood phantoms containing yeast and (2) epidermis-dermis mimicking solid-layered phantoms fabricated from polydimethylsiloxane, titanium oxide, hemoglobin, and coffee. The root-mean-square (RMS) deviations for fRBC for the two liquid phantoms were 11% and 5.3%, respectively, and 11% for the solid phantoms with highest hemoglobin signatures. The RMS deviation for S was 5.2% and 2.9%, respectively, for the liquid phantoms, and 2.9% for the solid phantoms. RMS deviation for the reduced scattering coefficient (μs‧), for the solid phantoms was 15% (475 to 850 nm). For the liquid phantoms, the RMS deviation in average vessel diameter (D) was 1 μm. In conclusion, the skin microcirculation parameters fRBC and S, as well as, μs‧ and D are estimated with reasonable accuracy.
Blood flow-independent accumulation of cisplatin in the guinea pig cochlea.
Miettinen, S; Laurell, G; Andersson, A; Johansson, R; Laurikainen, E
1997-01-01
Considerable interindividual variability in the ototoxic effect of cisplatin has become the unpredictable dose-limiting factor in its use as curative as well as palliative therapy. The drug accumulates in highly vascular areas in the cochlea, causing dose-related hair cell loss. The purpose of this study was to assess blood flow-dependent aspects of cisplatin absorption in the cochlea in order to better understand factors that may influence cisplatin-induced ototoxicity. The effect of reduced cochlear blood flow on the ototoxic action of cisplatin was studied in guinea pigs. Before cisplatin administration the cochlear vasculature in each animal was unilaterally pre-constricted, by the application of 2% epinephrine to the round window. A 20-30% reduction in cochlear blood flow, assessed by laser Doppler flowmetry, was maintained before and after intravenous infusion of 0.1% cisplatin. Cisplatin infusion affected cochlear blood flow but not vessel conductivity. The cochlear blood flow decrease, maintained by local epinephrine application to the round window during cisplatin infusion, did not alter the cisplatin-induced hearing loss. In addition, the concentration of free cisplatin in scala tympani perilymph did not differ between epinephrine-treated and non-treated ears. Our results indicate that cisplatin transport into the cochlea is not an energy-dependent process in the lateral wall vasculature.
Ototoxicity of salicylate, nonsteroidal antiinflammatory drugs, and quinine.
Jung, T T; Rhee, C K; Lee, C S; Park, Y S; Choi, D C
1993-10-01
Salicylates and most NSAIDS in high doses cause mild to moderate temporary hearing loss, either flat or greater in the high frequencies. Hearing loss is accompanied by tinnitus and suprathreshold changes. Salicylates may or may not exacerbate hearing loss and cochlear damage induced by noise. The mechanism of salicylate ototoxicity seems to be multifactorial. Morphologic studies suggest that no permanent cochlear damage occurs with salicylate ototoxicity. Electrophysiologic, morphologic, and in vitro data conclusively demonstrate that salicylate affects outer hair cells. In addition, salicylates appear to decrease cochlear blood flow. Salicylates and NSAIDs inhibit PG-forming cyclooxygenase, and recent studies suggest that abnormal levels of arachidonic acid metabolites consisting of decreased PGs and increased LTs may mediate salicylate ototoxicity. As with salicylate, quinine ototoxicity appears to be multifactorial in origin. The mechanism includes vasoconstriction and decreases in cochlear blood flow, as measured by laser Doppler flowmetry, motion photographic studies, and histologic studies. Reversible alterations of outer hair cells also appear to play an important role, as demonstrated by histology, electron microscopy, isolated hair cell studies, and cochlear potential evaluations. Unlike with salicylate, however, the role of prostaglandins in quinine ototoxicity has not been clearly demonstrated. Also, one of quinine's principal actions, antagonism of calcium-dependent potassium channels, has yet to be investigated for its potential role in ototoxicity.
Toda, Hiroko; Maruyama, Hitoshi; Budgell, Brian; Kurosawa, Mieko
2008-08-01
In urethane-anesthetized, artificially ventilated rats, alterations in dorsal spinal cord blood flow (SCBF) at the L4-6 level were measured with laser Doppler flowmetry in response to noxious mechanical cutaneous stimulation (pinching) of either a forepaw or a hindpaw. The stimulation was delivered ipsilaterally or contralaterally to the site of blood flow measurement. Pinching of the forepaw or the hindpaw on either side increased mean arterial pressure (MAP) to the same degree. However, the SCBF response to pinching of the ipsilateral hindpaw was significantly greater than that to other stimulations. These responses were not influenced by denervation of the baroreceptors. The responses of SCBF to pinching of the ipsilateral hindpaw persisted both after treatment with phenoxybenzamine and after spinalization at the C1-2 level, whereas the responses to pinching at other sites disappeared. The responses of MAP to stimulation at all four sites became negligible after treatment with phenoxybenzamine and after spinalization at the C1-2 level. These results indicate that noxious mechanical stimulation of the skin produces increases in SCBF via two mechanisms: one is via an elevation of systemic arterial pressure; the other is via a localized spinal mechanism evoked by ipsilateral, segmental inputs.
Harada, Kiyoshi; Sato, Masaru; Omura, Ken
2004-11-01
To examine the change in blood flow and recovery of sensibility in the maxillary dental pulp during and after maxillary distraction. The subjects included 5 patients undergoing high Le Fort I osteotomy and maxillary distraction (D-group) and a reference group of 14 patients who underwent a common single-segment Le Fort I osteotomy, 1-stage maxillary advancement, and mandibular setback surgery (C-group). Eleven (D-group) and 54 (C-group) maxillary incisors were assessed preoperatively and at 1-7 days, 14 days, and 3 months postoperatively. Pulpal blood flow (PBF) was measured by laser Doppler flowmetry, and pulpal sensibility (PS) was investigated by electrodiagnostics. From postoperative days 1 to 5 (the latency period), the PBF tended to be higher in the D-group than in the C-group. From day 6 to 3 months postoperatively (during and after maxillary distraction), the PBF values of the 2 groups were similar. The PS remained negative up to 14 days postoperatively in both groups. However, at 3 months after the operation, a higher proportion (90.9%) of teeth in the D-group was positive for PS. These results suggest that maxillary distraction is a favorable technique for maintenance of PBF and recovery of PS in the maxillary teeth after surgery.
Dunbar, Richard L.; Goel, Harsh; Tuteja, Sony; Song, Wen-Liang; Nathanson, Grace; Babar, Zeeshan; Lalic, Dusanka; Gelfand, Joel M.; Rader, Daniel J.; Grove, Gary L.
2017-01-01
Though cardioprotective, niacin monotherapy is limited by unpleasant cutaneous symptoms mimicking dermatitis: niacin-associated skin toxicity (NASTy). Niacin is prototypical of several emerging drugs suffering off-target rubefacient properties whereby agonizing the GPR109A receptor on cutaneous immune cells provokes vasodilation, prompting skin plethora and rubor, as well as dolor, tumor, and calor, and systemically, heat loss, frigor, chills, and rigors. Typically, NASTy effects are described by subjective patient-reported perception, at best semi-quantitative and bias-prone. Conversely, objective, quantitative, and unbiased methods measuring NASTy stigmata would facilitate research to abolish them, motivating development of several objective methods. In early drug development, such methods might better predict clinical tolerability in larger clinical trials. Measuring cutaneous stigmata may also aid investigations of vasospastic, ischemic, and inflammatory skin conditions. We present methods to measure NASTy physical stigmata to facilitate research into novel niacin mimetics/analogs, detailing characteristics of each technique following niacin, and how NASTy stigmata relate to symptom perception. We gave niacin orally and measured rubor by colorimetry and white-light spectroscopy, plethora by laser Doppler flowmetry, and calor/frigor by thermometry. Surprisingly, each stigma’s abruptness predicted symptom perception, whereas peak intensity did not. These methods are adaptable to study other rubefacient drugs or dermatologic and vascular disorders. PMID:28119443
Maar, Noemi; Pemp, Berthold; Kircher, Karl; Luksch, Alexandra; Weigert, Günther; Polska, Elzbieta; Tittl, Michael; Stur, Michael; Schmetterer, Leopold
2009-09-01
To investigate in patients with neovascular age-related macular degeneration (ARMD) the changes in ocular perfusion caused by single treatment with photodynamic therapy (PDT) by different non-invasive methods; to evaluate correlations between relative changes of ocular haemodynamic parameters after PDT among each other and compared to morphological parameters; and to assess this in relation to early changes of visual acuity. 17 consecutive patients with subfoveal choroidal neovascularization (CNV) caused by ARMD scheduled for PDT without previous PDT treatment (four patients with predominantly classic CNV and 13 patients with occult CNV). best-corrected visual acuity (before PDT, 6 and 8 weeks after PDT), fundus photography, fluorescein angiography, haemodynamic measurements with laser Doppler flowmetry (LDF), laser interferometry and ocular blood flow (OBF) tonometry (baseline and 1, 2, 6 and 8 weeks after treatment). choroidal blood flow (CHBF), fundus pulsation amplitude (FPA), pulsatile ocular blood flow (POBF), visual acuity. Changes smaller than 20% were considered clinically irrelevant. Ocular haemodynamic parameters did not change significantly in the follow-up period. Changes of haemodynamic parameters showed no correlation to treatment spot, morphological changes or visual acuity. Changes of visual acuity were comparable to results of earlier studies. Single treatment with PDT did not modify ocular blood flow parameters above 20% as assessed with different non-invasive methods.
Arteriovenous oscillations of the redox potential: Is the redox state influencing blood flow?
Poznanski, Jaroslaw; Szczesny, Pawel; Pawlinski, Bartosz; Mazurek, Tomasz; Zielenkiewicz, Piotr; Gajewski, Zdzislaw; Paczek, Leszek
2017-09-01
Studies on the regulation of human blood flow revealed several modes of oscillations with frequencies ranging from 0.005 to 1 Hz. Several mechanisms were proposed that might influence these oscillations, such as the activity of vascular endothelium, the neurogenic activity of vessel wall, the intrinsic activity of vascular smooth muscle, respiration, and heartbeat. These studies relied typically on non-invasive techniques, for example, laser Doppler flowmetry. Oscillations of biochemical markers were rarely coupled to blood flow. The redox potential difference between the artery and the vein was measured by platinum electrodes placed in the parallel homonymous femoral artery and the femoral vein of ventilated anesthetized pigs. Continuous measurement at 5 Hz sampling rate using a digital nanovoltmeter revealed fluctuating signals with three basic modes of oscillations: ∼ 1, ∼ 0.1 and ∼ 0.01 Hz. These signals clearly overlap with reported modes of oscillations in blood flow, suggesting coupling of the redox potential and blood flow. The amplitude of the oscillations associated with heart action was significantly smaller than for the other two modes, despite the fact that heart action has the greatest influence on blood flow. This finding suggests that redox potential in blood might be not a derivative but either a mediator or an effector of the blood flow control system.
Vestibular stimulation leads to distinct hemodynamic patterning
NASA Technical Reports Server (NTRS)
Kerman, I. A.; Emanuel, B. A.; Yates, B. J.
2000-01-01
Previous studies demonstrated that responses of a particular sympathetic nerve to vestibular stimulation depend on the type of tissue the nerve innervates as well as its anatomic location. In the present study, we sought to determine whether such precise patterning of vestibulosympathetic reflexes could lead to specific hemodynamic alterations in response to vestibular afferent activation. We simultaneously measured changes in systemic blood pressure and blood flow (with the use of Doppler flowmetry) to the hindlimb (femoral artery), forelimb (brachial artery), and kidney (renal artery) in chloralose-urethane-anesthetized, baroreceptor-denervated cats. Electrical vestibular stimulation led to depressor responses, 8 +/- 2 mmHg (mean +/- SE) in magnitude, that were accompanied by decreases in femoral vasoconstriction (23 +/- 4% decrease in vascular resistance or 36 +/- 7% increase in vascular conductance) and increases in brachial vascular tone (resistance increase of 10 +/- 6% and conductance decrease of 11 +/- 4%). Relatively small changes (<5%) in renal vascular tone were observed. In contrast, electrical stimulation of muscle and cutaneous afferents produced pressor responses (20 +/- 6 mmHg) that were accompanied by vasoconstriction in all three beds. These data suggest that vestibular inputs lead to a complex pattern of cardiovascular changes that is distinct from that which occurs in response to activation of other types of somatic afferents.
Effect of caffeine contained in a cup of coffee on microvascular function in healthy subjects.
Noguchi, Katsuhiko; Matsuzaki, Toshihiro; Sakanashi, Mayuko; Hamadate, Naobumi; Uchida, Taro; Kina-Tanada, Mika; Kubota, Haruaki; Nakasone, Junko; Sakanashi, Matao; Ueda, Shinichiro; Masuzaki, Hiroaki; Ishiuchi, Shogo; Ohya, Yusuke; Tsutsui, Masato
2015-02-01
Recent epidemiological studies have demonstrated that coffee drinking is associated with reduced mortality of cardiovascular disease. However, its precise mechanisms remain to be clarified. In this study, we examined whether single ingestion of caffeine contained in a cup of coffee improves microvascular function in healthy subjects. A double-blind, placebo-controlled, crossover study was performed in 27 healthy volunteers. A cup of either caffeinated or decaffeinated coffee was drunk by the subjects, and reactive hyperemia of finger blood flow was assessed by laser Doppler flowmetry. In an interval of more than 2 days, the same experimental protocol was repeated with another coffee in a crossover manner. Caffeinated coffee intake slightly but significantly elevated blood pressure and decreased finger blood flow as compared with decaffeinated coffee intake. There was no significant difference in heart rate between caffeinated and decaffeinated coffee intake. Importantly, caffeinated coffee intake significantly enhanced post-occlusive reactive hyperemia of finger blood flow, an index of microvascular endothelial function, compared with decaffeinated coffee intake. These results provide the first evidence that caffeine contained in a cup of coffee enhances microvascular function in healthy individuals. Copyright © 2015 Japanese Pharmacological Society. Production and hosting by Elsevier B.V. All rights reserved.
Dental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.
Abd-Elmeguid, Ashraf; Yu, Donald C
2009-03-01
In this second part of our 2-part review, we discuss recent research about pulp tests that determine the vitality of the tooth and clinically accepted pulp testers. A pain response to hot, cold or an electric pulp tester indicates the vitality of only a tooth's pulpal sensory supply; the response does not give any idea about the state of the pulp. Although the sensitivity of these tests is high, when false-positive and false-negative results occur, they may affect the treatment of the tooth. A tooth falsely diagnosed as nonvital with an electric pulp tester may undergo an unnecessary root canal, whereas one falsely diagnosed as vital may be left untreated, causing the necrotic tissue to destroy the supporting tissues (resorption). The vascular supply is more important to the determination of the health of the pulp than the sensory supply. Pulp death is caused by cessation of blood flow and may result in a necrotic pulp, even though the pulpal sensory supply may still be viable. The pulp can be healed only if the circulating blood flow is healthy. Although still under investigation, diagnostic devices that examine pulpal blood flow, such as the pulse oximeter and laser Doppler flowmetry, show promising results for the assessment of pulp vitality.
Glutamate control of pulpal blood flow in the incisor dental pulp of the rat.
Zerari-Mailly, Fouzia; Braud, Adeline; Davido, Nicolas; Touré, Babacar; Azérad, Jean; Boucher, Yves
2012-10-01
Glutamate is present in primary sensory afferents innervating the dental pulp and is known to exert vasoactive effects. The aims of this study were (i) to assess pulpal blood flow (PBF) after glutamate infusion in the dental pulp and (ii) to observe the distribution of glutamatergic nerve fibers expressing the vesicular transporters of glutamate (VGluT). The PBF was monitored with laser Doppler flowmetry before and after glutamate (0.5 M) infusion in the dental pulp vs. saline infusion. Immunochemistry for VGluT1, 2, and 3 was performed in addition to immunochemistry for the vascular and neuronal markers smooth-muscle actin (SMA), isolectin B4 (IB4), and calcitonin gene-related peptide (CGRP). Glutamate infusion resulted in a PBF increase that lasted for 60 s. Positive immunolabeling was observed for the three glutamate transporters, but was more pronounced for VGluT3. Moreover, VGluT3 immunoreactivity was observed within nerve fibers entering the dental pulp and terminating at the periphery and at the vicinity of odontoblasts. Also, VGluT3 was colocalized with the vascular marker SMA, and in some nerve fibers with IB4, but not with CGRP. This study provides support for a control of dental pulp microcirculation by neurons expressing VGluT3. © 2012 Eur J Oral Sci.
Warrington, Junie P.; Fan, Fan; Murphy, Sydney R.; Roman, Richard J.; Drummond, Heather A.; Granger, Joey P.; Ryan, Michael J.
2014-01-01
Abstract Cerebrovascular events contribute to ~40% of preeclampsia/eclampsia‐related deaths, and neurological symptoms are common among preeclamptic patients. We previously reported that placental ischemia, induced by reducing utero‐placental perfusion pressure, leads to impaired myogenic reactivity and cerebral edema in the pregnant rat. Whether the impaired myogenic reactivity is associated with altered cerebral blood flow (CBF) autoregulation and the edema is due to altered blood–brain barrier (BBB) permeability remains unclear. Therefore, we tested the hypothesis that placental ischemia leads to impaired CBF autoregulation and a disruption of the BBB. CBF autoregulation, measured in vivo by laser Doppler flowmetry, was significantly impaired in placental ischemic rats. Brain water content was increased in the anterior cerebrum of placental ischemic rats and BBB permeability, assayed using the Evans blue extravasation method, was increased in the anterior cerebrum. The expression of the tight junction proteins: claudin‐1 was increased in the posterior cerebrum, while zonula occludens‐1, and occludin, were not significantly altered in either the anterior or posterior cerebrum. These results are consistent with the hypothesis that placental ischemia mediates anterior cerebral edema through impaired CBF autoregulation and associated increased transmission of pressure to small vessels that increases BBB permeability leading to cerebral edema. PMID:25168877
Hubing, Kimberly A.; Wingo, Jonathan E.; Brothers, R. Matthew; Coso, Juan Del; Low, David A.; Crandall, Craig G.
2010-01-01
Objective The purpose of this study was to test the hypothesis that local inhibition of nitric oxide and prostaglandin synthesis attenuates cutaneous vasodilator responses during post-menopausal hot flashes. Methods Four microdialysis membranes were inserted into forearm skin (dorsal surface) of 8 post-menopausal women (mean ± SD, 51±7 y). Ringers solution (control), 10mM Ketorolac (Keto) to inhibit prostaglandin synthesis, 10mM NG-L-arginine methyl ester (L-NAME) to inhibit nitric oxide synthase, and a combination of 10mM Keto + 10mM L-NAME were each infused at the separate sites. Skin blood flow at each site was indexed using laser-Doppler flowmetry. Cutaneous vascular conductance (CVC) was calculated as laser-Doppler flux/mean arterial blood pressure and was expressed as a percentage of the maximal calculated CVC (CVCmax) obtained following infusion of 50mM sodium nitropruside at all sites at the end of the study. Data from 13 hot flashes were analyzed. Results At the control site, the mean ± SD peak increase in CVC was 15.5±6% CVCmax units. This value was not different relative to the peak increase in CVC at the Keto site (13.0±5 % CVCmax units, P = 0.09). However, the peak increase in CVC during the flash was attenuated at the L-NAME and L-NAME + Keto sites (7.4±4 % CVCmax units and 8.7±7 % CVCmax units, respectively) relative to both the control and the Keto sites (P<0.05 for both comparisons). There were no significant differences in the peak increases in sweat rate between any of the sites (P = 0.24). Conclusions These data demonstrate that cutaneous vasodilation during a hot flash has a nitric oxide component. Increases in CVC despite the inhibition of prostaglandin synthesis suggest prostaglandins do not contribute to cutaneous vasodilation during a hot flash. PMID:20505548
[Tibolone's effect on retinal and ophthalmic arteries flowmetry].
Souza, Marco Aurélio Martins de; Geber, Selmo
2008-11-01
to evaluate the effect of tibolone use on doppler-velocimetric parameters of ophthalmic and retinal arteries. clinical, prospective, longitudinal, randomized, placebo-controlled, triple-blind study, in which among 100 menopausal women, 50 have used 2.5 mg of the active principle tibolone (Tib Group) and 50, placebo as a means to form the control-group (Plac Group). In the Tib Group, 44 of the 50 women returned after 84 days to finish the exams, and in the Plac Group, 47. The ophthalmic and retinal arteries were studied to determine the resistance index (RI), the pulsatility index (PI) and the systole/diastole ratio (S/D). Assessments have been done before and 84 days after medication. The t-Student test has been used for the comparison of means between the groups in independent samples, as well as for within-group comparisons in dependent samples. in both groups, the women's characteristics were similar in age, menopause duration, body mass index, arterial blood pressure, deliveries and cardiac rate. The Tib Group presented the following values in the ophthalmic artery: RI(pre)=0.71+/-0.05, RI(post)0.72+/-0.08 (p=0.43); PI(pre)=1.29+/-0.22, PI(post)=1.30+/-0.25 (p=0.4) and S/D(pre)=3.49+/-0.77, SD(post)=3.65+/-0.94 (p=0.32). In the retinal artery, the following values have been found: RI(pre)=0.67+/-0.09, RI(post)=0.69+/-0.10 (p=0.7); PI(pre)=1.20+/-0.29, PI(post)=1.22+/-0.3 (p=0.2) and SD(pre)=3.29+/-0.95, SD(post)=3.30+/-1.07 (p=0.3). Also, the tibolone and control groups did not show any significant difference in regard to the above indexes in the end of the study. the 2.5 mg dose of tibolone had no effect on the Doppler velocimetry indexes of the ophthalmic and retinal arteries.
Harahsheh, Basel
2012-01-01
Objectives To assess the results of transit time flowmetry (TTF) on a consecutive group of coronary artery bypass grafting (CABG) patients at Queen Alia Heart Institute. Methods Intraoperative flow measurements of a consecutive group of 436 CABG patients. The flow pattern for each coronary artery system was assessed including mean flows, pulsatility index (PI) and the need for revision. Results A total of 1394 grafts in 436 patients were assessed (3.2 grafts per patient), wherein 100 grafts showed inadequate flowmetry results (7.2%); most of which were in the circumflex and right coronary artery systems with a percentage of 9.4% and the least in the LAD system with a percentage of 4.4%. The mean flow of grafts to the LAD system was 33.4±5.3 mL/min with a PI of 2.4±0.4; while the mean for grafts to the circumflex artery system was 35.1±7.2 mL/min with a PI of 3.5±0.7. The mean for the right coronary artery was 38.4±5.9 mL/min with a PI of 2.6±0.6. Revisions occurred in five patients (1.1%). Suboptimal grafts to the LAD system exhibited a flow of 14.1±7.4 mL/min with a PI of 6.9±1.7. While for the circumflex system a flow of 5.5±3.6 mL/min was reported with a PI of 10.4±7.8; and for the right coronary system a flow of 7.2±5.3 mL/min with a PI of 9.1±5.7 was reported. Conclusion Grafts to the LAD system showed the best flowmetry results compared to grafts to the circumflex and right coronary systems. A proportion of poor grafts were revised. PMID:23226818
Antiinflammatory effect of BPC 157 on experimental periodontitis in rats.
Keremi, B; Lohinai, Z; Komora, P; Duhaj, S; Borsi, K; Jobbagy-Ovari, G; Kallo, K; Szekely, A D; Fazekas, A; Dobo-Nagy, C; Sikiric, P; Varga, G
2009-12-01
The pentadecapeptide BPC 157 has been shown to have anti-inflammatory and wound healing effects on multiple target tissues and organs. The purpose of the present study was to investigate the effect of BPC 157 on inflammation and bone resorption in experimental periodontitis in rats. First the acute effect of BPC was tested on gingival blood flow by laser doppler flowmetry. Then periodontitis was produced by a silk ligature placed around the lower left first molar. Rats were treated with BPC 157 (once daily for 12 days) or vehicle. At day 13, the gingivomucosal tissues encircling the molars were removed on both sides. Inflammation was assessed by Evans blue plasma extravasation technique and by histology. Alveolar bone loss was analyzed by microCT. BPC 157 had no effect on gingivomucosal blood flow. Twelve day ligature caused a significantly increased Evans blue extravasation in the gingivomucosal tissue, histological signs of inflammation, and alveolar bone destruction. BPC 157 treatment significantly reduced both plasma extravasation, histological alterations and alveolar bone resorption. In conclusion, systemic application of BPC 157 does not alter blood circulation in healthy gingiva. Chronic application of the peptide has potent antiinflammatory effects on periodontal tissues in ligature induced periodontitis in rats. Taken together, this proof of concept study suggests that BPC 157 may represent a new peptide candidate in the treatment of periodontal disease.
De Michele, Manuela; Touzani, Omar; Foster, Alan C; Fieschi, Cesare; Sette, Giuliano; McCulloch, James
2005-09-01
The expression of corticotrophin-releasing factor (CRF) receptors in cerebral arteries and arterioles suggests that CRF may modulate cerebral blood flow (CBF). In the present study, the effects of CRF, CRF-like peptides and the CRF broad spectrum antagonist DPhe-CRF on CBF have been investigated under normal physiologic conditions and in the margins of focal ischaemic insult. The experiments were carried out in anaesthetised and ventilated rats. Changes in CBF after subarachnoid microapplication of CRF and related peptides were assessed with a laser-Doppler flowmetry (LDF) probe. In the ischaemic animals, agents were injected approximately 60 minutes after permanent middle cerebral artery occlusion (MCAo). Microapplication of CRF and related peptides in normal rats into the subarachnoid space produced sustained concentration-dependent increases in CBF. This effect was attenuated by co-application with DPhe-CRF, which did not alter CBF itself. A second microapplication of CRF 30 min after the first failed to produce increases in CBF in normal animals. Microapplication of CRF in the subarachnoid space overlying the ischaemic cortex effected minor increases in CBF whereas D-Phe-CRF had no significant effect on CBF. Activation of the CRF peptidergic system increases CBF in the rat. Repeated activation of CRF receptors results in tachyphylaxis of the vasodilator response. CRF vasodilator response is still present after MCAo in the ischaemic penumbra, suggesting that the CRF peptidergic system may modulate CBF in ischaemic stroke.
NASA Astrophysics Data System (ADS)
Semyachkina-Glushkovskaya, O. V.; Pavlov, A. N.; Semyachkin-Glushkovskiy, I. A.; Gekalyuk, A. S.; Ulanova, M. V.; Lychagov, V. V.; Tuchin, V. V.
2014-09-01
The adrenergic system plays an important role in regulation of central and peripheral circulation in normal state and during hemorrhage. Because the impaired gastric mucosal blood flow (GMBF) is the major cause of gastroduodenal lesions, including ulcer bleeding (UB), we studied the adrenergic mechanism responsible for regulation of GMBF in rats with a model of stress-induced UB (SUB) using the laser Doppler flowmetry (LDF). First, we examined the effect of adrenaline on GMBF in rats under normal state and during UB. In all healthy animals the submucosal adrenaline injection caused a decrease in local GMBF. During UB the submucosal injection of adrenaline was accompanied by less pronounced GMBF suppression in 30,3% rats with SUB vs. healthy ones. In 69,7% rats with SUB we observed the increase in local GMBF after submucosal injection of adrenaline. Second, we studied the sensitivity of gastric β2-adrenoreceptors and the activity of two factors which are involved in β2-adrenomediated vasorelaxation-KATP -channels and NO. The effects of submucosal injection of isoproterenol, ICI118551 and glybenclamide on GMBF as well as NO levels in gastric tissue were significantly elevated in rats with SUB vs. healthy rats. Thus, our results indicate that high activation of gastric β2-adrenoreceptors associated with the increased vascular KATP -channels activity and elevated NO production is the important adrenergic mechanism implicated in the pathogenesis of UB.
Augmentation of sensory-evoked hemodynamic response in an early Alzheimer's disease mouse model.
Kim, Jinho; Jeong, Yong
2013-01-01
Based on enlarged blood oxygen level-dependent (BOLD) responses in cognitively normal subjects at risk for Alzheimer's disease (AD), compensatory neuronal hyperactivation has been proposed as an early marker for diagnosis of AD. The BOLD response results from neurovascular coupling, i.e., hemodynamic response induced by neuronal activity. However, there has been no evidence of task-induced increases in hemodynamic response in animal models of AD. Here, we observed an augmented hemodynamic response pattern in a transgenic AβPP(SWE)/PS1ΔE9 mouse model of AD using three in vivo imaging methods: intrinsic optical signal imaging, multi-photon laser scanning microscopy, and laser Doppler flowmetry. Sensory stimulation resulted in augmented and prolonged hemodynamic responses in transgenic mice evidenced by changes in total, oxygenated, and deoxygenated hemoglobin concentration. This difference between transgenic and wild-type mice was significant at 7 months of age when amyloid plaques and cerebral amyloid angiopathy had developed but not at younger or older ages. Correspondingly, sensory stimulation-induced pial arteriole diameter was also augmented and prolonged in transgenic mice at 7 months of age. Cerebral blood flow response in transgenic mice was augmented but not prolonged. These results are consistent with the existence of BOLD signal hyperactivation in non-demented AD-risk human subjects, supporting its potential use as an early diagnostic marker of AD.
Gastric distention exacerbates ischemia in a rodent model of partial gastric devascularization.
Urschel, J D; Antkowiak, J G; Takita, H
1997-11-01
Occult ischemia of the mobilized gastric fundus is an important etiologic factor for esophagogastric anastomotic leaks after esophagectomy. Postoperative gastric distention is another possible predisposing factor for anastomotic leakage. We hypothesized that gastric distention could worsen gastric ischemia. To test this hypothesis, gastric tissue perfusion was studied in 20 Sprague-Dawley rats. Baseline serosal gastric tissue perfusion was measured by laser-Doppler flowmetry at a point 10 mm distal to the gastroesophageal junction. Perfusion was measured after left gastric artery occlusion, gastric distention to 20 cm water pressure, and combined left gastric artery occlusion and gastric distention. Gastric tissue perfusion (in tissue perfusion units, TPU) was 64.2 +/- 9.1 TPU at baseline measurement, 18.6 +/- 4.3 TPU after left gastric artery occlusion, 22.0 +/- 4.1 TPU after gastric distention, and 7.8 +/- 1.8 TPU after combined left gastric artery occlusion and gastric distention. Distention (P < 0.0001) and arterial occlusion (P < 0.0001) both reduced gastric tissue perfusion; of the two, arterial occlusion produced the greatest reduction in perfusion (P < 0.021). The combination of distention and arterial occlusion caused greater reduction in gastric perfusion than either factor alone (P < 0.0001). In this model, gastric distention exacerbated the ischemia produced by partial gastric devascularization. In clinical esophageal surgery, postoperative gastric distention may similarly potentiate the ischemic effects of gastric transposition for esophageal reconstruction.
Dynamics of thermographic skin temperature response during squat exercise at two different speeds.
Formenti, Damiano; Ludwig, Nicola; Trecroci, Athos; Gargano, Marco; Michielon, Giovanni; Caumo, Andrea; Alberti, Giampietro
2016-07-01
Low intensity resistance training with slow movement and tonic force generation has been shown to create blood flow restriction within muscles that may affect thermoregulation through the skin. We aimed to investigate the influence of two speeds of exercise execution on skin temperature dynamics using infrared thermography. Thirteen active males performed randomly two sessions of squat exercise (normal speed, 1s eccentric/1s concentric phase, 1s; slow speed, 5s eccentric/5s concentric phase, 5s), using ~50% of 1 maximal repetition. Thermal images of ST above muscles quadriceps were recorded at a rate of 0.05Hz before the exercise (to determine basal ST) and for 480s following the initiation of the exercise (to determine the nonsteady-state time course of ST). Results showed that ST changed more slowly during the 5s exercise (p=0.002), whereas the delta (with respect to basal) excursions were similar for the two exercises (p>0.05). In summary, our data provided a detailed nonsteady-state portrait of ST changes following squat exercises executed at two different speeds. These results lay the basis for further investigations entailing the joint use of infrared thermography and Doppler flowmetry to study the events taking place both at the skin and the muscle level during exercises executed at slow speed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Piilgaard, Henning; Lauritzen, Martin
2009-09-01
Cortical spreading depression (CSD) is associated with a dramatic failure of brain ion homeostasis and increased energy metabolism. There is strong clinical and experimental evidence to suggest that CSD is the mechanism of migraine, and involved in progressive neuronal injury in stroke and head trauma. Here we tested the hypothesis that single episodes of CSD induced acute hypoxia, and prolonged impairment of neurovascular and neurometabolic coupling. Cortical spreading depression was induced in rat frontal cortex, whereas cortical electrical activity and local field potentials (LFPs) were recorded by glass microelectrodes, cerebral blood flow (CBF) by laser-Doppler flowmetry, and tissue oxygen tension (tpO(2)) with polarographic microelectrodes. Cortical spreading depression increased cerebral metabolic rate of oxygen (CMRO(2)) by 71%+/-6.7% and CBF by 238%+/-48.1% for 1 to 2 mins. For the following 2 h, basal tpO(2) and CBF were reduced whereas basal CMRO(2) was persistently elevated by 8.1%+/-2.9%. In addition, within first hour after CSD we found impaired neurovascular coupling (LFP versus CBF), whereas neurometabolic coupling (LFP versus CMRO(2)) remained unaffected. Impaired neurovascular coupling was explained by both reduced vascular reactivity and suppressed function of cortical inhibitory interneurons. The protracted effects of CSD on basal CMRO(2) and neurovascular coupling may contribute to cellular dysfunction in patients with migraine and acutely injured cerebral cortex.
Buise, Marc P; Ince, Can; Tilanus, Hugo W; Klein, Jan; Gommers, Diederik; van Bommel, Jasper
2005-04-01
Esophagectomy followed by gastric tube reconstruction is the surgical treatment of choice for patients with esophageal cancer. Complications of the cervical anastomosis are associated with impaired microvascular blood flow (MBF) and ischemia in the gastric fundus. The aim of the present study was to differentiate whether the decrease in MBF is a result of arterial insufficiency or of venous congestion. To do this we assessed MBF, microvascular hemoglobin oxygen saturation (muHbSo(2)), and microvascular hemoglobin concentration (muHbcon) simultaneously during different stages of gastric tube reconstruction. In 14 patients, MBF was determined with laser Doppler flowmetry, and muHbSo(2) and muHbcon were determined with reflectance spectro- photometry. After completion of the anastomosis, nitroglycerin was applied at the fundus. Although MBF did not change significantly in the pylorus, MBF decreased progressively during surgery in the fundus from 210 +/- 18 Arbitrary Units at baseline (normal stomach) to 52 +/- 9 Arbitrary Units after completion of reconstruction (mean +/- sem; P < 0.05). There was no change in muHbSo(2) and muHbcon during the reconstruction. After application of nitroglycerin, MBF doubled. We conclude that MBF decreases during gastric tube reconstruction but that muHbSo(2) and muHbcon do not. This decrease might be the result of venous congestion, which can partly be counteracted by application of nitroglycerin.
Vazquez, Alberto L.; Fukuda, Mitsuhiro; Crowley, Justin C.; Kim, Seong-Gi
2014-01-01
Hemodynamic responses are commonly used to map brain activity; however, their spatial limits have remained unclear because of the lack of a well-defined and malleable spatial stimulus. To examine the properties of neural activity and hemodynamic responses, multiunit activity, local field potential, cerebral blood volume (CBV)-sensitive optical imaging, and laser Doppler flowmetry were measured from the somatosensory cortex of transgenic mice expressing Channelrhodopsin-2 in cortex Layer 5 pyramidal neurons. The magnitude and extent of neural and hemodynamic responses were modulated using different photo-stimulation parameters and compared with those induced by somatosensory stimulation. Photo-stimulation-evoked spiking activity across cortical layers was similar to forelimb stimulation, although their activity originated in different layers. Hemodynamic responses induced by forelimb- and photo-stimulation were similar in magnitude and shape, although the former were slightly larger in amplitude and wider in extent. Altogether, the neurovascular relationship differed between these 2 stimulation pathways, but photo-stimulation-evoked changes in neural and hemodynamic activities were linearly correlated. Hemodynamic point spread functions were estimated from the photo-stimulation data and its full-width at half-maximum ranged between 103 and 175 µm. Therefore, submillimeter functional structures separated by a few hundred micrometers may be resolved using hemodynamic methods, such as optical imaging and functional magnetic resonance imaging. PMID:23761666
Hayashi, Keiji; Kawashima, Takayo; Suzuki, Yuichi
2012-07-01
To examine the effect of menstrual cycle on the ventilatory sensitivity to rising body temperature, ten healthy women exercised for ~60 min on a cycle ergometer at 50% of peak oxygen uptake during the follicular and luteal phases of their cycle. Esophageal temperature, mean skin temperature, mean body temperature, minute ventilation, and tidal volume were all significantly higher at baseline and during exercise in the luteal phase than the follicular phase. On the other hand, end-tidal partial pressure of carbon dioxide was significantly lower during exercise in the luteal phase than the follicular phase. Plotting ventilatory parameters against esophageal temperature revealed there to be no significant menstrual cycle-related differences in the slopes or intercepts of the regression lines, although minute ventilation and tidal volume did significantly differ during exercise with mild hyperthermia. To evaluate the cutaneous vasodilatory response, relative laser-Doppler flowmetry values were plotted against mean body temperature, which revealed that the mean body temperature threshold for cutaneous vasodilation was significantly higher in the luteal phase than the follicular phase, but there were no significant differences in the sensitivity or peak values. These results suggest that the menstrual cycle phase influences the cutaneous vasodilatory response during exercise and the ventilatory response at rest and during exercise with mild hyperthermia, but it does not influence ventilatory responses during exercise with moderate hyperthermia.
Hong, Guosong; Lee, Jerry C.; Jha, Arshi; Diao, Shuo; Nakayama, Karina H.; Hou, Luqia; Doyle, Timothy C.; Robinson, Joshua T.; Antaris, Alexander L.; Dai, Hongjie; Cooke, John P.; Huang, Ngan F.
2014-01-01
Background Real-time vascular imaging that provides both anatomic and hemodynamic information could greatly facilitate the diagnosis of vascular diseases and provide accurate assessment of therapeutic effects. Here we have developed a novel fluorescence-based all-optical method, named near-infrared II (NIR-II) fluorescence imaging, to image murine hindlimb vasculature and blood flow in an experimental model of peripheral arterial disease, by exploiting fluorescence in the NIR-II region (1000–1400 nm) of photon wavelengths. Methods and Results Owing to the reduced photon scattering of NIR-II fluorescence compared to traditional NIR fluorescence imaging and thus much deeper penetration depth into the body, we demonstrated that the mouse hindlimb vasculature could be imaged with higher spatial resolution than in vivo microCT. Furthermore, imaging over 26 days revealed a significant increase in hindlimb microvascular density in response to experimentally induced ischemia within the first 8 days of the surgery (P < 0.005), which was confirmed by histological analysis of microvascular density. Moreover, the tissue perfusion in the ischemic hindlimb could be quantitatively measured by the dynamic NIR-II method, revealing the temporal kinetics of blood flow recovery that resembled microbead-based blood flowmetry and laser Doppler blood spectroscopy. Conclusions The penetration depth of millimeters, high spatial resolution and fast acquisition rate of NIR-II imaging makes it a useful imaging tool for murine models of vascular disease. PMID:24657826
Tuncer, Serhan; Ayhan, Suhan; Findikcioglu, Kemal; Ergun, Hakan; Tuncer, Ilhan
2011-09-01
The effects of piracetam on flap survival, ischemia-reperfusion (I/R) injury, and vascular endothelial growth factor (VEGF) expression were evaluated in this study. Unipedicled epigastric flap model was used in 36 rats and was evaluated within 4 groups. The flap was elevated and untreated in Group 1. Postoperative piracetam treatment was given for 7 days in Group 2. In Group 3, 4 hours of ischemia and 2 hours of reperfusion were applied. I/R was applied to Group 4 and piracetam was given 30 minutes before reperfusion and postoperatively for 7 days. Laser Doppler flowmetry was used to measure blood flow changes. VEGF expression was determined using immunohistochemical methods on tissue samples taken after the completion of 2 hours reperfusion in groups 3 and 4. Flap necrosis was measured on the day 7 in all groups. Blood flow rates did not show significant difference between piracetam treated and untreated I/R groups. Piracetam significantly reduced necrosis area both in ischemic and nonischemic flaps ( P < 0.05). VEGF expression was significantly increased in piracetam-treated Group 4 compared with Group 3 ( P = 0.005). This experimental study demonstrates that systemic piracetam treatment improves survival of pedicled flaps, reduces necrosis amounts, and increases VEGF expression in I/R induced flaps. © Thieme Medical Publishers.
NASA Astrophysics Data System (ADS)
Hickey, Michelle; Phillips, Justin P.; Kyriacou, Panayiotis
2015-03-01
The aim of the current work is to investigate the possibility of augmenting pulse oximetry algorithms to enable the estimation of venous parameters in peripheral tissues. In order to further understand the contribution of venous blood to the photoplethysmographic (PPG) signal, recordings were made from six healthy volunteer subjects during an exercise in which the right hand was placed in various positions above and below heart level. The left hand was kept at heart level as a control while the right hand was moved. A custom-made two-channel dual wavelength PPG instrumentation system was used to obtain the red and infrared plethysmographic signals from both the right and left index fingers simultaneously using identical sensors. Laser Doppler flowmetry signals were also recorded from an adjacent fingertip on the right hand. Analysis of all acquired PPG signals indicated changes in both ac and dc amplitude of the right hand when the position was changed, while those obtained from the left (control) hand remained relatively constant. Most clearly, in the change from heart level to 50cm below heart level there is a substantial decrease in both dc and ac amplitudes. This decrease in dc amplitude most likely corresponds to increased venous pooling, and hence increased absorption of light. It is speculated that the decrease in ac PPG amplitude is due to reduced arterial emptying during diastole due to increased downstream resistance due to venous pooling.
Hong, Guosong; Lee, Jerry C; Jha, Arshi; Diao, Shuo; Nakayama, Karina H; Hou, Luqia; Doyle, Timothy C; Robinson, Joshua T; Antaris, Alexander L; Dai, Hongjie; Cooke, John P; Huang, Ngan F
2014-05-01
Real-time vascular imaging that provides both anatomic and hemodynamic information could greatly facilitate the diagnosis of vascular diseases and provide accurate assessment of therapeutic effects. Here, we have developed a novel fluorescence-based all-optical method, named near-infrared II (NIR-II) fluorescence imaging, to image murine hindlimb vasculature and blood flow in an experimental model of peripheral arterial disease, by exploiting fluorescence in the NIR-II region (1000-1400 nm) of photon wavelengths. Because of the reduced photon scattering of NIR-II fluorescence compared with traditional NIR fluorescence imaging and thus much deeper penetration depth into the body, we demonstrated that the mouse hindlimb vasculature could be imaged with higher spatial resolution than in vivo microscopic computed tomography. Furthermore, imaging during 26 days revealed a significant increase in hindlimb microvascular density in response to experimentally induced ischemia within the first 8 days of the surgery (P<0.005), which was confirmed by histological analysis of microvascular density. Moreover, the tissue perfusion in the ischemic hindlimb could be quantitatively measured by the dynamic NIR-II method, revealing the temporal kinetics of blood flow recovery that resembled microbead-based blood flowmetry and laser Doppler blood spectroscopy. The penetration depth of millimeters, high spatial resolution, and fast acquisition rate of NIR-II imaging make it a useful imaging tool for murine models of vascular disease. © 2014 American Heart Association, Inc.
Role of NO in choroidal blood flow regulation during isometric exercise in healthy humans.
Luksch, Alexandra; Polska, Elzbieta; Imhof, Andrea; Schering, Joanne; Fuchsjäger-Mayrl, Gabriele; Wolzt, Michael; Schmetterer, Leopold
2003-02-01
Nitric oxide (NO) is an important regulator of basal choroidal blood flow. Animal experiments indicate that NO is also involved in choroidal blood flow regulation during changes in ocular perfusion pressure and inhibition of NO synthase (NOS) has been reported to shift choroidal pressure-flow curves to the right. The hypothesis for the study was that inhibition of NOS may influence choroidal blood flow during isometric exercise. To test this hypothesis, a randomized, double-masked, placebo-controlled, three-way crossover study was performed in 12 healthy male volunteers. Subjects received on different study days intravenous infusions of N(G)-monomethyl-L-arginine (L-NMMA), phenylephrine, or placebo. During these infusion periods, subjects were asked to squat for 6 minutes. Choroidal blood flow was assessed with laser Doppler flowmetry, and ocular perfusion pressure (OPP) was calculated from mean arterial pressure and intraocular pressure. L-NMMA and phenylephrine increased resting OPP by 10% and 13%, respectively, but only L-NMMA reduced resting choroidal blood flow (-17%, P < 0.001). The relative increase in OPP during isometric exercise was comparable with all drugs administered. Isometric exercise increased choroidal blood flow during administration of placebo and phenylephrine, but not during administration of L-NMMA (P < 0.001 vs. placebo). These data indicate that NO plays an important role in the regulation of choroidal blood flow during isometric exercise.
Tittl, Michael; Maar, Noemi; Polska, Elzbieta; Weigert, Günther; Stur, Michael; Schmetterer, Leopold
2005-12-01
Imaging studies suggest that the choroidal vasculature may be altered in central serous chorioretinopathy. Little is known, however, about the regulation of ocular blood flow in patients with central serous chorioretinopathy (CSC). The hypothesis for the present study was that choroidal blood flow changes during an increase in ocular perfusion pressure induced by isometric exercise may be altered in CSC. An observer-masked, two-cohort study was performed in 14 nonsmoking patients with chronic-relapsing but inactive CSC and in 14 healthy nonsmoking volunteers. Both groups were matched for age and sex. Subfoveal choroidal blood flow (CBF) was assessed with laser Doppler flowmetry, and ocular perfusion pressure (OPP) was calculated from mean arterial pressure (MAP) and intraocular pressure (IOP). Changes of CBF during isometric exercise over a period of 6 minutes were measured. Whereas the increase of MAP, the pulse rate, and the OPP were comparable between the two study groups, subfoveal CBF increased significantly more in the group of patients with CSC (P < 0.001). IOP remained unchanged in both groups during isometric exercise. At an 85% increase in OPP, subfoveal CBF was approximately twice as high in the patients with CSC compared with the healthy control group. The data indicate an abnormal subfoveal CBF regulation in patients with relapsing CSC compared with age-matched, nonsmoking, healthy volunteers during isometric exercise.
In Vivo Assays for Assessing the Role of the Wilms' Tumor Suppressor 1 (Wt1) in Angiogenesis.
McGregor, Richard J; Ogley, R; Hadoke, Pwf; Hastie, Nicholas
2016-01-01
The Wilms' tumor suppressor gene (WT1) is widely expressed during neovascularization, but it is almost entirely absent in quiescent adult vasculature. However, in vessels undergoing angiogenesis, WT1 is dramatically upregulated. Studies have shown Wt1 has a role in both tumor and ischemic angiogenesis, but the mechanism of Wt1 action in angiogenic tissue remains to be elucidated. Here, we describe two methods for induction of in vivo angiogenesis (subcutaneous sponge implantation, femoral artery ligation) that can be used to assess the influence of Wt1 on new blood vessel formation. Subcutaneously implanted sponges stimulate an inflammatory and fibrotic response including cell infiltration and angiogenesis. Femoral artery ligation creates ischemia in the distal hindlimb and produces an angiogenic response to reperfuse the limb which can be quantified in vivo by laser Doppler flowmetry. In both of these models, the role of Wt1 in the angiogenic process can be assessed using histological/immunohistochemical staining, molecular analysis (qPCR) and flow cytometry. Furthermore, combined with suitable genetic modifications, these models can be used to explore the causal relationship between Wt1 expression and angiogenesis and to trace the lineage of cells expressing Wt1. This approach will help to clarify the importance of Wt1 in regulating neovascularization in the adult, and its potential as a therapeutic target.
NASA Astrophysics Data System (ADS)
Abookasis, David; Volkov, Boris; Kofman, Itamar
2017-02-01
During the last four decades, various optical techniques have been proposed and intensively used for biomedical diagnosis and therapy both in animal model and in human. These techniques have several advantages over the traditional existing methods: simplicity in structure, low-cost, easy to handle, portable, can be used repeatedly over time near the patient bedside for continues monitoring, and offer high spatiotemporal resolution. In this work, we demonstrate the use of two optical imaging modalities namely, spatially modulated illumination and dual-wavelength laser speckle to image the changes in brain tissue chromophores, morphology, and metabolic before, during, and after the onset of focal traumatic brain injury in intact mouse head (n=15). Injury was applied in anesthetized mice by weight-drop apparatus using 50gram metal rod striking the mouse's head. Following data analysis, we show a series of hemodynamic and structural changes over time including higher deoxyhemoglobin, reduction in oxygen saturation and blood flow, cell swelling, etc., in comparison with baseline measurements. In addition, to validate the monitoring of cerebral blood flow by the imaging system, measurements with laser Doppler flowmetry were also performed (n=5), which confirmed reduction in blood flow following injury. Overall, our result demonstrates the capability of diffuse optical modalities to monitor and map brain tissue optical and physiological properties following brain trauma.
Integrated quadruple stress echocardiography.
Picano, Eugenio; Morrone, Doralisa; Scali, Maria C; Huqi, Alda; Coviello, Katia; Ciampi, Quirino
2018-04-11
Stress Echocardiography (SE) is an established diagnostic technique. For 40 years, the cornerstone of the technique has been the detection of regional wall motion abnormalities (RWMA), due to the underlying physiologically-relevant epicardial coronary artery stenosis. In the last decade, three new parameters (more objective than RWMA) have shown the potential to integrate and comple- ment RWMA: 1- B-lines, also known as ultrasound lung comets, as a marker of extra-vascular lung water, measured using lung ultrasound with the 4-site simplified scan symmetrically of the antero- lateral thorax on the third intercostal space, from mid-axillary to anterior axillary and mid- clavicular line; 2-left ventricular contractile reserve (LVCR), assessed as the peak stress/rest ratio of left ventricular force, also known as elastance (systolic arterial pressure by cuff sphygmomanome- ter/end-systolic volume from 2D echocardiography); 3- coronary flow velocity reserve (CFVR) on left anterior descending coronary artery, calculated as peak stress/rest ratio of diastolic peak flow velocity assessed using pulsed-wave Doppler. The 4 parameters (RWMA, B-lines, LVCR and CFVR) now converge conceptually, logistically, and methodologically in the Integrated Quadruple (IQ)-SE. IQ-SE optimizes the versatility of SE to include in a one-stop shop the core "ABCD" (Asynergy+B-lines+Contractile reserve+Doppler flowmetry) protocol. It allows a synoptic assess- ment of parameters mirroring the epicardial artery stenosis (RWMA), interstitial lung water (B- lines), myocardial function (LVCR) and small coronary vessels (CFVR). Each variable has a clear clinical correlate, different and complementary to all others: RWMA identify an ischemic vs non- ischemic heart; B-lines a wet vs dry lung; LVCR a strong vs weak heart; CFVR a warm vs cold heart. IQ-SE is highly feasible, with minimal increase in the imaging and analysis time, and obvi- ous diagnostic and prognostic impact also beyond coronary artery disease - especially in heart fail- ure. Large scale effectiveness studies with IQ-SE are now under way with the Stress Echo 2020 study, and will provide the necessary evidence base prior to large scale acceptance of the tech- nique.
Schiffner, René; Bischoff, Sabine Juliane; Lehmann, Thomas; Rakers, Florian; Rupprecht, Sven; Reiche, Juliane; Matziolis, Georg; Schubert, Harald; Schwab, Matthias; Huber, Otmar; Schmidt, Martin
2017-01-01
Background: Maintenance of brain circulation during shock is sufficient to prevent subcortical injury but the cerebral cortex is not spared. This suggests area-specific regulation of cerebral blood flow (CBF) during hemorrhage. Methods: Cortical and subcortical CBF were continuously measured during blood loss (≤50%) and subsequent reperfusion using laser Doppler flowmetry. Blood gases, mean arterial blood pressure (MABP), heart rate and renal blood flow were also monitored. Urapidil was used for α1A-adrenergic receptor blockade in dosages, which did not modify the MABP-response to blood loss. Western blot and quantitative reverse transcription polymerase chain reactions were used to determine adrenergic receptor expression in brain arterioles. Results: During hypovolemia subcortical CBF was maintained at 81 ± 6% of baseline, whereas cortical CBF decreased to 40 ± 4% (p < 0.001). Reperfusion led to peak CBFs of about 70% above baseline in both brain regions. α1A-Adrenergic blockade massively reduced subcortical CBF during hemorrhage and reperfusion, and prevented hyperperfusion during reperfusion in the cortex. α1A-mRNA expression was significantly higher in the cortex, whereas α1D-mRNA expression was higher in the subcortex (p < 0.001). Conclusions: α1-Adrenergic receptors are critical for perfusion redistribution: activity of the α1A-receptor subtype is a prerequisite for redistribution of CBF, whereas the α1D-receptor subtype may determine the magnitude of redistribution responses. PMID:28492488
Schiffner, René; Bischoff, Sabine Juliane; Lehmann, Thomas; Rakers, Florian; Rupprecht, Sven; Reiche, Juliane; Matziolis, Georg; Schubert, Harald; Schwab, Matthias; Huber, Otmar; Schmidt, Martin
2017-05-11
Maintenance of brain circulation during shock is sufficient to prevent subcortical injury but the cerebral cortex is not spared. This suggests area-specific regulation of cerebral blood flow (CBF) during hemorrhage. Cortical and subcortical CBF were continuously measured during blood loss (≤50%) and subsequent reperfusion using laser Doppler flowmetry. Blood gases, mean arterial blood pressure (MABP), heart rate and renal blood flow were also monitored. Urapidil was used for α1A-adrenergic receptor blockade in dosages, which did not modify the MABP-response to blood loss. Western blot and quantitative reverse transcription polymerase chain reactions were used to determine adrenergic receptor expression in brain arterioles. During hypovolemia subcortical CBF was maintained at 81 ± 6% of baseline, whereas cortical CBF decreased to 40 ± 4% ( p < 0.001). Reperfusion led to peak CBFs of about 70% above baseline in both brain regions. α1A-Adrenergic blockade massively reduced subcortical CBF during hemorrhage and reperfusion, and prevented hyperperfusion during reperfusion in the cortex. α1A-mRNA expression was significantly higher in the cortex, whereas α1D-mRNA expression was higher in the subcortex ( p < 0.001). α1-Adrenergic receptors are critical for perfusion redistribution: activity of the α1A-receptor subtype is a prerequisite for redistribution of CBF, whereas the α1D-receptor subtype may determine the magnitude of redistribution responses.
Assadi, A; Desebbe, O; Kaminski, C; Rimmelé, T; Bénatir, F; Goudable, J; Chassard, D; Allaouchiche, B
2008-01-01
We tested the hypothesis that sodium nitroprusside (SNP) might improve the impairment of hepatosplanchnic microcirculatory blood flow (MBF) in septic shock. Fourteen pigs were anaesthetized and their lungs mechanically ventilated. Sepsis was induced with i.v. infusion of live Pseudomonas aeruginosa [1x10(8) colony forming units (CFU) ml(-1) kg(-1)] for 1 h. Sixty minutes later, the animals received in a random succession either SNP or normal saline for 30 min. Mean arterial pressure (MAP), cardiac index (CI), mean pulmonary artery pressure (MPAP), carbon dioxide tension of the ileal mucosa (PCO2; by gas tonometry), ileal mucosal and hepatic MBF by laser Doppler flowmetry, blood gases, and lactates were assessed before, during administration, and 30 min after discontinuing the test drug. Bacterial infusion promoted hypodynamic shock (MAP -18%, CI -33%, ileal MBF -19%, and hepatic MBF -27%), which was converted to normodynamic shock by resuscitation. During SNP infusion, ileal mucosal MBF significantly increased (+19%) compared with control (P = 0.033). Although hepatic MBF increased (+42% from baseline), this did not differ from control. In order to maintain a constant central venous pressure and MAP, fluid loading and norepinephrine (P < 0.01) were increased. Acid-base status was not altered by SNP. In a resuscitated porcine model of the early phase of septic shock, SNP improved ileal mucosal MBF but required a concomitant increase in fluid and norepinephrine supplements to maintain constant systemic haemodynamic parameters.
NASA Astrophysics Data System (ADS)
Kozlov, Valentine I.; Skobelkin, Oleg K.; Fatkullin, Ildar; Terman, Oleg A.; Chizhov, Gennadii; Gabidullina, Rushania
1994-12-01
To study the possibility of using Nd:YAG laser to weld the tissues of the uterus experiments in rats and dogs have been conducted. With the biomicroscopy and the laser Doppler flowmetry we have evaluated the microcirculation in the uterus wall under traditional suture and laser welding suture. As a model of the wound, the dissection of serosa and muscles of the organ wall have been used. In laser welding suture we have welded the zone of tissue about 1 mm3 with the laser (power density 270 W/cm2). Histological control has been fulfilled on various phases of the healing process. The investigation of the uterus wall demonstrates that there are zones of microcirculation disorders in tissues: (1) the zone of coagulation of microvessels and adjacent tissues (about 100 micrometers ); (2) the zone of stasis (150 - 200 micrometers ); (3) the zone of reactive-destructive changes of microvessels (300 micrometers ), (4) the zone of malfunctional microcirculatory changes (600 micrometers ). The coagulation of microvessels changes the character of inflammation and the healing process, decreases the exudation phase and the leucocyte infiltration of tissues, and accelerates the capillary growth. In contrast with traditional suture, in the case of laser welding suture the edema and hemorrhagic signs are less expressed. The complete restoration of microcirculation under laser welding suture has been observed by the fourteenth day of the healing process. Under the traditional suture method normalization of tissue nutritious blood flow has been achieved by 21 days.
Cohen, H E; Hall, J; Harris, N; McCabe, C S; Blake, D R; Jänig, W
2012-02-01
Cortical reorganisation of sensory, motor and autonomic systems can lead to dysfunctional central integrative control. This may contribute to signs and symptoms of Complex Regional Pain Syndrome (CRPS), including pain. It has been hypothesised that central neuroplastic changes may cause afferent sensory feedback conflicts and produce pain. We investigated autonomic responses produced by ambiguous visual stimuli (AVS) in CRPS, and their relationship to pain. Thirty CRPS patients with upper limb involvement and 30 age and sex matched healthy controls had sympathetic autonomic function assessed using laser Doppler flowmetry of the finger pulp at baseline and while viewing a control figure or AVS. Compared to controls, there were diminished vasoconstrictor responses and a significant difference in the ratio of response between affected and unaffected limbs (symmetry ratio) to a deep breath and viewing AVS. While viewing visual stimuli, 33.5% of patients had asymmetric vasomotor responses and all healthy controls had a homologous symmetric pattern of response. Nineteen (61%) CRPS patients had enhanced pain within seconds of viewing the AVS. All the asymmetric vasomotor responses were in this group, and were not predictable from baseline autonomic function. Ten patients had accompanying dystonic reactions in their affected limb: 50% were in the asymmetric sub-group. In conclusion, there is a group of CRPS patients that demonstrate abnormal pain networks interacting with central somatomotor and autonomic integrational pathways. © 2011 European Federation of International Association for the Study of Pain Chapters.
DiResta, G R; Lee, J; Healey, J H; Levchenko, A; Larson, S M; Arbit, E
2000-05-01
A mechanical drainage system, the "artificial lymphatic system" (ALS), consisting of a vacuum source and drain, is evaluated for its ability to aspirate the interstitial fluids responsible for the elevated interstitial fluid pressure (IFP) observed in solid tumors. IFP, pH, and pO2 radial profiles were measured before and after aspiration using wick-in-needle (WIN) probes, needle pH and oxygen electrodes, respectively. Laser Doppler flowmetry measured temporal changes in blood flow rate (BFR) at the tumor surface during aspiration. The WIN probe and IFP profile data were analyzed using numerical simulation and distributed mathematical models, respectively. The model parameter, P(E), reflecting central tumor IFP, was reduced from 15.3 to 5.7 mm Hg in neuroblastoma and from 13.3 to 12.1 mm Hg in Walker 256, respectively, following aspiration. The simulation demonstrated that spatial averaging inherent in WIN measurements reduced the calculated magnitude of the model parameter changes. IFP was significantly lower (p<0.05), especially in regions surrounding the drain, and BFR was significantly higher (p<0.05) following 25 and 45 min of aspiration, respectively; pH and pO2 profiles increased following aspiration. The experimental and mathematical findings suggest that ALS aspiration may be a viable way of reducing IFP and increasing BFR, pO2, and pH and should enhance solid tumor chemo and radiation therapy.
Non-Invasive Health Diagnostics using Eye as a 'Window to the Body'
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.
2002-01-01
As a 'window to the body', the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and help develop preventative/therapeutic countermeasures early. The effects of space travel on human body are similar to those of normal aging. For example, radiation exposure in space could lead to formation of cataracts and cancer by damaging the DNA and causing gene mutation. Additionally, the zero-gravity environment causes fluid shifts in the upper extremities of the body and changes the way blood flows and organ system performs. Here on Earth, cataract, age-related macular degeneration (AMD), diabetic retinopathy (DR), and glaucoma are major eye diseases and are expected to double in next two decades. To detect, prevent, and treat untoward effects of prolonged space travel in real-time requires the development of non-invasive diagnostic technologies that are compact and powerful. We are developing fiber-optic sensors to evaluate the ocular tissues in health, aging, and disease employing the techniques of dynamic light scattering (cataract, uveitis, Alzheimer's, glaucoma, DR, radiation damage, refractive surgery outcomes), auto-fluorescence (aging, DR), laser-Doppler flowmetry (choroidal blood flow), Raman spectroscopy (AMD), polarimetry (diabetes), and retinal oximetry (occult blood loss). The non-invasive feature of these technologies integrated in a head-mounted/goggles-like device permits frequent repetition of tests, enabling evaluation of the results to therapy that may ultimately be useful in various telemedicine applications on Earth and in space.
Liao, Fuyuan; Jan, Yih-Kuen
2017-01-01
Diabetic foot ulcers (DFU) are a major complication in diabetics. Impaired microvascular reactivity is a major contributor to the development of DFU and has been traditionally quantified by time-domain or frequency-domain measures of skin blood flow (SBF). These measures, however, are unable to characterize the changes of nonlinear dynamics of SBF associated with diabetes and peripheral neuropathy. The objective of this study was to investigate altered nonlinear dynamics of skin blood flow in the plantar foot of diabetics with peripheral neuropathy. 18 type 2 diabetics with peripheral neuropathy and 8 healthy controls were recruited. SBF at the first metatarsal head in response to a loading pressure of 300 mmHg and a local heating was measured using laser Doppler flowmetry. A sample entropy approach was used to quantify the degree of regularity of SBF. Our results showed that the regularity degree of SBF in the diabetic foot underwent only small changes during post-occlusive reactive hyperemia and thermally induced biphasic response compared to non-diabetics. SBF of the diabetic foot has higher degree of irregularity during reactive hyperemia because of attenuated myogenic activity, and demonstrated higher regularity during the biphasic response largely due to significantly enhanced cardiac activities. This study suggests that the regularity degree of SBF at the first metatarsal head could be used to assess impaired microvascular reactivity and thus may be used to assess the risk for DFU in diabetics with peripheralneuropathy.
Källman, Ulrika; Engström, Maria; Bergstrand, Sara; Ek, Anna-Christina; Fredrikson, Mats; Lindberg, Lars-Göran; Lindgren, Margareta
2015-03-01
Although repositioning is considered an important intervention to prevent pressure ulcers, tissue response during loading in different lying positions has not been adequately explored. To compare the effects of different lying positions on interface pressure, skin temperature, and tissue blood flow in nursing home residents. From May 2011 to August 2012, interface pressure, skin temperature, and blood flow at three tissue depths were measured for 1 hr over the sacrum in 30° supine tilt and 0° supine positions and over the trochanter major in 30° lateral and 90° lateral positions in 25 residents aged 65 years or older. Measurement of interface pressure was accomplished using a pneumatic pressure transmitter connected to a digital manometer, skin temperature using a temperature sensor, and blood flow using photoplethysmography and laser Doppler flowmetry. Interface pressure was significantly higher in the 0° supine and 90° lateral positions than in 30° supine tilt and 30° lateral positions. The mean skin temperature increased from baseline in all positions. Blood flow was significantly higher in the 30° supine tilt position compared to the other positions. A hyperemic response in the post pressure period was seen at almost all tissue depths and positions. The 30° supine tilt position generated less interface pressure and allowed greater tissue perfusion, suggesting that this position is the most beneficial. © The Author(s) 2014.
Kaner, Doğan; Zhao, Han; Arnold, Wolfgang; Terheyden, Hendrik; Friedmann, Anton
2017-06-01
Soft tissue (ST) dehiscence with graft exposure is a frequent complication of vertical augmentation. Flap dehiscence is caused by failure to achieve tension-free primary wound closure and by the impairment of flap microcirculation due to surgical trauma. Soft tissue expansion (STE) increases ST quality and quantity prior to reconstructive surgery. We hypothesized that flap preconditioning using STE would reduce the incidence of ST complications after bone augmentation and that optimized ST healing would improve the outcome of bone regeneration. Self-filling tissue expanders were implanted in mandibular bone defects in ten beagle dogs. After expansion, alloplastic scaffolds were placed for vertical bone augmentation in STE sites and in control sites without STE pre-treatment. ST flap microcirculation was analysed using laser Doppler flowmetry. The incidence of graft exposures was evaluated after 2 weeks. Bone formation was assessed after 2 months, using histomorphometry and immunohistochemistry. Test sites showed significantly less impairment of perfusion and faster recovery of microcirculation after bone augmentation. Furthermore, no flap dehiscences occurred in STE sites. Bone regeneration was found in both groups; however, significantly greater formation of new bone was detected in test sites with preceding STE. Preconditioning using STE improved ST healing and bone formation after vertical augmentation. The combination of STE and the subsequent placement of alloplastic scaffolds may facilitate the reconstruction of severe bone defects. © 2016 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
Khoshnevis, Sepideh; Craik, Natalie K; Matthew Brothers, R; Diller, Kenneth R
2016-03-01
The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P < 0.001) that persisted throughout the duration of the rewarming period. In addition, there was a hysteresis effect between CVC and skin temperature during the cooling and subsequent rewarming cycle (P < 0.01). Mixed model regression (MMR) showed a significant difference in the slopes of the CVC-skin temperature curves during cooling and rewarming (P < 0.001). Piecewise regression was used to investigate the temperature thresholds for acceleration of CVC during the cooling and rewarming periods. The two thresholds were shown to be significantly different (P = 0.003). The results show that localized cooling causes significant vasoconstriction that continues beyond the active cooling period despite skin temperatures returning toward baseline values. The significant and persistent reduction in skin perfusion may contribute to nonfreezing cold injury (NFCI) associated with cryotherapy.
Khoshnevis, Sepideh; Craik, Natalie K.; Matthew Brothers, R.; Diller, Kenneth R.
2016-01-01
The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P < 0.001) that persisted throughout the duration of the rewarming period. In addition, there was a hysteresis effect between CVC and skin temperature during the cooling and subsequent rewarming cycle (P < 0.01). Mixed model regression (MMR) showed a significant difference in the slopes of the CVC–skin temperature curves during cooling and rewarming (P < 0.001). Piecewise regression was used to investigate the temperature thresholds for acceleration of CVC during the cooling and rewarming periods. The two thresholds were shown to be significantly different (P = 0.003). The results show that localized cooling causes significant vasoconstriction that continues beyond the active cooling period despite skin temperatures returning toward baseline values. The significant and persistent reduction in skin perfusion may contribute to nonfreezing cold injury (NFCI) associated with cryotherapy. PMID:26632263
Woodward, Kirsty A.; Unnithan, Vish; Hopkins, Nicola D.
2015-01-01
Context Kinesiology tape (KT) has become popular among athletes for both injury prevention and rehabilitation due to its reported therapeutic effects, including facilitation of lymphatic flow and enhanced peripheral blood flow. However, evidence to support such claims is insufficient. Objective To determine whether KT improves skin blood flow (SkBF) responses in young, elite soccer players. Design Randomized crossover study. Setting Research laboratory. Patients or Other Participants Thirteen healthy, elite, adolescent male soccer players (age = 14.7 ± 0.6 years). Intervention(s) Participants completed 2 experimental trials; during trial 1, the volar aspect of the dominant forearm was taped. Forearm SkBF was measured within the taped area and 3 cm lateral to the taped area. During trial 2, no tape was applied to either site. Both trials were performed within 7 days. Main Outcome Measure(s) Baseline and maximal thermally (42°C) stimulated SkBF responses were assessed using laser Doppler flowmetry. Continuously measured SkBF and derived mean arterial pressure obtained at 5-minute intervals were used to calculate cutaneous vascular conductance (CVC), the primary outcome measure. Results No differences were observed for baseline SkBF or CVC between trials or measurement sites. After local heating, no differences were evident for SkBF or CVC between trials or measurement sites. Conclusions Our findings suggest that, in healthy, trained adolescent males, KT was not associated with increased forearm SkBF. PMID:26445024
Schonberger, Robert B.; Worden, William S.; Shahmohammadi, Kaveh; Menn, Kirsten; Silverman, Tyler J.; Stout, Robert G.; Shelley, Kirk H.; Silverman, David G.
2007-01-01
Objective: Assessments of endothelial cell function with acetylcholine have typically used systemic, regional intra-arterial, or iontophoretic delivery of drug. Each of these techniques induces systemic and/or local changes that compromise their safety or effectiveness. Using translucent drug preparations applied under laser Doppler flowmetry (LDF) probes, we tested whether local vasodilation can be induced with non-iontophoretic transdermal delivery of acetylcholine and how such dilation would compare to the dilation achieved with topical nitroglycerin in healthy volunteers. Methods: Ten subjects without known vascular disease were recruited for LDF monitoring at sites of drug application for this preliminary investigation. Topical acetylcholine chloride, nitroglycerin, and placebo were applied via translucent patches to the forehead directly below LDF probes. Results: LDF readings increased by 406 percent (245 percent to 566 percent) and 36 percent (26 percent to 46 percent), respectively, at the acetylcholine and placebo sites (p = .005 by Wilcoxon Signed Rank Test (WSRT) for acetylcholine vs. placebo); and they increased by 365 percent (179 percent to 550 percent) at the nitroglycerin site (p = .005 by WSRT for nitroglycerin vs. placebo; p = .6 vs. acetylcholine). Conclusion: Transdermal delivery of acetylcholine can induce significant local vasodilatory responses comparable to those achieved with nitroglycerin without requiring iontophoresis. The means of transdermal delivery and monitoring described herein may constitute a new minimally invasive way to interrogate the microvasculature and thereby assess the microcirculatory changes induced by various disorders and therapeutic interventions. PMID:17876370
Vertiz-Hernandez, Antonio; Castaneda-Hernandez, Gilberto; Martinez-Cruz, Angelina; Cruz-Antonio, Leticia; Grijalva, Israel; Guizar-Sahagun, Gabriel
2007-12-01
High hepatic extraction drugs--such as phenacetin, methylprednisolone, and cyclosporine--exhibit an increased bioavailability after acute spinal cord injury (SCI) due to an impaired clearance. For these drugs, metabolic clearance depends on hepatic blood flow. Thus, it is possible that pharmacokinetic alterations can be reversed by increasing liver perfusion. Therefore, we evaluated the effect of L-arginine, a nitric oxide precursor, on the pharmacokinetics of a prototype drug with high hepatic extraction, and on hepatic microvascular blood flow (MVBF) after acute SCI. Pharmacokinetics of i.v. phenacetin was studied in rats 24 h after a severe T-5 spinal cord contusion; animals being pretreated with L-arginine 100 mg/kg i.v. or vehicle. MVBF was assessed under similar experimental conditions using laser Doppler flowmetry. SCI significantly altered phenacetin pharmacokinetics. Clearance was significantly reduced, resulting in a prolonged half-life and an increase in bioavailability, while volume of distribution was decreased. Pharmacokinetic alterations were reversed when injured rats were pretreated with L -arginine. It was also observed that L-arginine significantly increased hepatic MVBF in injured rats, notwithstanding it exhibited a limited effect on sham-injured animals. Our data hence suggest that L-arginine is able to reverse SCI-induced alterations in phenacetin pharmacokinetics due to an impaired hepatic MVBF, likely by increased nitric oxide synthesis leading to vasodilation. Further studies are warranted to examine the potential usefulness of nitric oxide supplementation in a clinical setting.
Knobloch, K; Gohritz, A; Busch, K; Spies, M; Vogt, P M
2007-04-01
Medical leech therapy has enjoyed a renaissance in the world of reconstructive microsurgery during recent years. Especially venous congestion is decreased using hirudo medicinalis application such as following replantation of amputated fingers or congested flaps. They provide a temporary relief to venous engorgement whilst venous drainage is re-established. Living in symbiosis with Aeromonas hydrophila, who can digest the sixfold blood meal related to their body weight, and a broad number of anticoagulant agents such as the thrombin inhibitor hirudin, apyrase as well as collagenase, hyaluronidase, Factor Xa inhibitor and fibrinase I and II, leeches decrease venous congestion. Laser Doppler flowmetry could demonstrate a significant increase in superficial skin perfusion following leech application 16 mm around the biting zone. Following the initial blood meal accounting for about 2.5 ml, the anticoagulant effect of the various leeches enzymes follows within the next 5-6 hours, which both account for the beneficial effects. Infection associated with leech therapy is a documented complication of leech application, with reported incidences ranging from 2.4 to 20 % and a chinolone antibiotic is currently recommended to face the potential Aeromonas hydrophila infection. Anemia is a second adverse effect during medicinal leech application which has to be taken account with repetitive blood samples. Besides the successful applications of leeches in various applications in plastic and reconstructive microsurgery, randomized-controlled trials are pending to elucidate the value of hirudo medicinalis according to evidence-based criteria above from case series and case studies.
Patterns of Sympathetic Responses Induced by Different Stress Tasks
Fechir, M; Schlereth, T; Purat, T; Kritzmann, S; Geber, C; Eberle, T; Gamer, M; Birklein, F
2008-01-01
Stress tasks are used to induce sympathetic nervous system (SNS) arousal. However, the efficacy and the patterns of SNS activation have not been systematically compared between different tasks. Therefore, we analyzed SNS activation during the following stress tasks: Presentation of negative, positive, and – as a control – neutral affective pictures, Color-Word interference test (CWT), mental arithmetic under time limit, singing a song aloud, and giving a spontaneous talk. We examined 11 healthy subjects and recorded the following SNS parameters: Activation of emotional sweating by quantitative sudometry, skin vasoconstriction by laser-Doppler flowmetry, heart rate by ECG, blood pressure by determination of pulse wave transit time (PWTT), and electromyographic (EMG) activity of the trapezius muscle. Moreover, subjective stress ratings were acquired for each task using a visual analog scale. All tasks were felt significantly stressful when compared to viewing neutral pictures. However, SNS activation was not reliable: Affective pictures did not induce a significant SNS response; singing, giving a talk and mental arithmetic selectively increased heart rate and emotional sweating. Only the CWT globally activated the SNS. Regarding all tasks, induction of emotional sweating, increase of heart rate and blood pressure significantly correlated with subjective stress ratings, in contrast to EMG and skin vasoconstriction. Our results show that the activation of the SNS widely varies depending on the stress task. Different stress tasks differently activate the SNS, which is an important finding when considering sympathetic reactions - in clinical situations and in research. PMID:19018304
Rothenberger, Jens; Krauss, Sabrina; Held, Manuel; Bender, Dominik; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Constantinescu, Mihai Adrian; Jaminet, Patrick
2014-11-01
Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Schmidl, Doreen; Boltz, Agnes; Kaya, Semira; Werkmeister, Rene; Dragostinoff, Nikolaus; Lasta, Michael; Polska, Elzbieta; Garhöfer, Gerhard; Schmetterer, Leopold
2012-07-01
We compared the response of choroidal and optic nerve head blood flow (ChBF, ONHBF) in response to an increase in ocular perfusion pressure (OPP) during isometric exercise and during a decrease in OPP during an artificial increase in intraocular pressure (IOP). We included 96 healthy subjects in our study. In 48 subjects OPP was increased by 6 minutes of squatting, and either ONHBF (n = 24) or ChBF (n = 24) was measured continuously. In 48 other healthy subjects either ONHBF (n = 24) or ChBF (n = 24) was measured continuously during a period of artificial increase in IOP using a suction cup. All blood flow measurements were done using laser Doppler flowmetry. During all experiments the response in blood flow was less pronounced than the response in OPP, indicating for flow regulation. During isometric exercise ChBF regulated better than ONHBF (P = 0.023). During artificial IOP increase ONHBF regulated better than ChBF (P = 0.001). Inter-individual variability in blood flow responses was high. During squatting ONHBF decreased considerably below baseline ONHBF when OPP fluctuated in 3 subjects, although OPP still was much higher than at baseline. This phenomenon was not observed in the choroid. Our data indicate that regulation of ChBF and ONHBF during changes in OPP is different and complex. In some subjects performing squatting, considerable ONHBF reductions were observed during OPP fluctuations, although OPP still was high. Whether this predisposes to ocular disease remains unclear.
Effect of nifedipine on choroidal blood flow regulation during isometric exercise.
Schmidl, Doreen; Prinz, Ana; Kolodjaschna, Julia; Polska, Elzbieta; Luksch, Alexandra; Fuchsjager-Mayrl, Gabriele; Garhofer, Gerhard; Schmetterer, Leopold
2012-01-25
To determine whether nifedipine, an L-type calcium channel blocker, alters choroidal blood flow (ChBF) regulation during isometric exercise in healthy subjects. The study was carried out in a randomized, placebo-controlled, double-masked, two-way crossover design. Fifteen healthy male subjects were randomly assigned to receive either placebo or nifedipine on two different study days. Subfoveal ChBF was measured with laser Doppler flowmetry while the study participants performed isometric exercise (squatting). This was performed before drug administration and during infusion of nifedipine and placebo, respectively. Mean arterial pressure (MAP) and intraocular pressure (IOP) were measured noninvasively, and ocular perfusion pressure (OPP) was calculated as ⅔ MAP-IOP. MAP and OPP increased significantly during all squatting periods (P < 0.01). The increase in ChBF was less pronounced than the increase in OPP during isometric exercise. Nifedipine did not alter the OPP increase in response to isometric exercise, but it significantly augmented the exercise-induced increase in ChBF (P < 0.001 vs. placebo). Although ChBF increased by a maximum of 14.2% ± 9.2% during the squatting period when placebo was administered, the maximum increase during administration of nifedipine was 23.2% ± 7.2%. In conclusion, the data of the present study suggest that nifedipine augments the ChBF response to an experimental increase in OPP. In addition, it confirms that the choroidal vasculature has a significant regulatory capacity over wide ranges of OPPs during isometric exercise. (ClinicalTrials.gov number, NCT00280462.).
Funane, Tsukasa; Sato, Hiroki; Yahata, Noriaki; Takizawa, Ryu; Nishimura, Yukika; Kinoshita, Akihide; Katura, Takusige; Atsumori, Hirokazu; Fukuda, Masato; Kasai, Kiyoto; Koizumi, Hideaki; Kiguchi, Masashi
2015-01-01
Abstract. It has been reported that a functional near-infrared spectroscopy (fNIRS) signal can be contaminated by extracerebral contributions. Many algorithms using multidistance separations to address this issue have been proposed, but their spatial separation performance has rarely been validated with simultaneous measurements of fNIRS and functional magnetic resonance imaging (fMRI). We previously proposed a method for discriminating between deep and shallow contributions in fNIRS signals, referred to as the multidistance independent component analysis (MD-ICA) method. In this study, to validate the MD-ICA method from the spatial aspect, multidistance fNIRS, fMRI, and laser-Doppler-flowmetry signals were simultaneously obtained for 12 healthy adult males during three tasks. The fNIRS signal was separated into deep and shallow signals by using the MD-ICA method, and the correlation between the waveforms of the separated fNIRS signals and the gray matter blood oxygenation level–dependent signals was analyzed. A three-way analysis of variance (signal depth×Hb kind×task) indicated that the main effect of fNIRS signal depth on the correlation is significant [F(1,1286)=5.34, p<0.05]. This result indicates that the MD-ICA method successfully separates fNIRS signals into spatially deep and shallow signals, and the accuracy and reliability of the fNIRS signal will be improved with the method. PMID:26157983
Wen, Zhuoyu; Xu, Xiaomeng; Xu, Lili; Yang, Lian; Xu, Xiaohui; Zhu, Juehua; Wu, Li; Jiang, Yongjun; Liu, Xinfeng
2017-06-15
Intraluminal middle cerebral artery occlusion (MCAO) is the most widely used model of stroke. We aimed to predict the outcome of MCAO using a combination of fine behavioural tests for the prediction of unsuccessful surgery in mice leading to no infarction, haemorrhage and unexpected death. MCAO was performed on adult mice under the guidance of laser-Doppler flowmetry (LDF) to warrant a decrease in regional cerebral blood flow (rCBF) in the MCA territory. Four outcomes of MCAO were defined according to histological analysis: infarction, no infarction, haemorrhage and unexpected death (death within 24h post-surgery). Fine behavioural tests including the rotarod, modified neurological severity score (mNSS), Clark general and Clark focal tests were performed separately at 6h, 12h and 24h post-stroke. A total of 94 mice were included in the analysis. The infarction rate associated with MCAO was 58.5% (55/94). After optimization of the timing and behavioural tests, we found that higher Clark focal (>17.5) or higher mNSS scores (>10) were markedly related to early death, whereas a lower mNSS score (<3.5) was indicative of a tendency to show no infarction at 6h post-stroke. After 24h post-stroke, there was a positive correlation between the infarct volume and Clark focal results. Behavioural tests could help to predict the outcomes in the MCAO mouse model. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Krupatkin, A I
2012-01-01
Laser Doppler flowmetry, laser spectrophotometry of oxygen saturation and fluorescence determination of NAD-H/FAD ratio were carried out at 30 humans in the upper extremity skin zones with and without arteriole-venule anastomoses (AVA). For the first time it was shown that wavelet-analysis of oxygen saturation and microvascular blood flow oscillations was an effective approach to noninvasive estimation of skin oxygen extraction (OE) and oxygen consumption rate (OC). OE = (SaO2--SvO2)/SaO2, where SaO2 (%) and SvO2(%) are the oxygen saturation of arterial and venular blood, correspondingly. If the ratio between amplitudes of cardiac rhythm (Ac, p.u.) and respiratory rhythm (Ar, p.u.) Ac/Ar < or = 1, SvO2 = SO2. In the case of Ac/Ar >1, SvO2 = SO2/(Ac/Ar). OC = Mnutr x (SaO2-SvO2) in p.u. x %O2, where Mnutr--value of nutritive perfusion (p.u.). Mnutr = M/SI, where SI--shunting index of blood flow in microvessels. The values of perfusion, OE and OC were higher in the skin with AVA than in the skin without AVA. The values of perfusion and oxygen saturation were more variable in the skin with AVA. The greatest significance for tissue metabolism have the oxygen diffused from the smallest arterioles and capillaries. The contribution increased to tissue metabolism of total perfusion and of oxygen diffused from arterioles in the conditions of tissue ischemia.
Consumption of flavanol-rich cocoa acutely increases microcirculation in human skin.
Neukam, Karin; Stahl, Wilhelm; Tronnier, Hagen; Sies, Helmut; Heinrich, Ulrike
2007-02-01
Long term cocoa ingestion leads to an increased resistance against UV-induced erythema and a lowered transepidermal water loss. To investigate the acute effects of a single dose of cocoa rich in flavanols on dermal microcirculation. In a crossover design study, 10 healthy women ingested a cocoa drink (100 ml) with high (329 mg) or low (27 mg) content of flavanols. The major flavanol monomer in both drinks was epicatechin, 61 mg in the high flavanol, and 6.6 mg in the low flavanol product per 100 ml. Dermal blood flow and oxygen saturation of hemoglobin were examined by laser Doppler flowmetry and spectroscopically at 1 mm skin depth at t = 0, 1, 2, 4, and 6 h. At the same time points, plasma levels of total epicatechin (free compound plus conjugates) were measured by means of HPLC. Subsequent to the intake of high flavanol cocoa, dermal blood flow was significantly increased by 1.7-fold at t = 2 h and oxygen saturation was elevated 1.8-fold. No statistically significant changes were found upon intake of low flavanol cocoa. Maximum plasma levels of total epicatechin were observed 1 h after ingestion of the high flavanol cocoa drink, 11.6 +/- 7.4 nmol/l at baseline, and 62.9 +/- 35.8 nmol/l at 1 h. No change of total epicatechin was found in the low flavanol group. Flavanol-rich cocoa consumption acutely increases dermal blood flow and oxygen saturation.
Low-level laser therapy and Calendula officinalis in repairing diabetic foot ulcers.
Carvalho, Ana Flávia Machado de; Feitosa, Maura Cristina Porto; Coelho, Nayana Pinheiro Machado de Freitas; Rebêlo, Veruska Cronemberger Nogueira; Castro, Juçara Gonçalves de; Sousa, Patrícia Regina Gomes de; Feitosa, Valrian Campos; Arisawa, Emilia Angela Lo Schiavo
2016-01-01
To evaluate the effects of low-level laser therapy isolated and associated with Calendula officinalis oil in treating diabetic foot ulcers. An experimental, randomized, controlled, prospective, interventional clinical case study using a quantitative approach. The sample consisted of 32 diabetic patients of both genders. Participants were randomly divided into four groups. Doppler Ultrasound evaluation of the Ankle-Brachial Index, brief pain inventory and analog pain scale were performed at baseline and after 30 days. Reduced pain was observed in the Low-level laser therapy and Low-level laser therapy associated with Essential Fatty Acids groups (p<0.01). Regarding the Ankle-Brachial Index and Doppler Ultrasound, all groups remained stable. By analyzing lesion area reduction, Low-level laser therapy associated with Essential fatty acids group showed a significance of p=0.0032, and the Low-level laser therapy group showed p=0.0428. Low-level laser therapy, performed alone or associated with the Calendula officinalis oil was effective in relieving pain and accelerating the tissue repair process of diabetic foot. Avaliar os efeitos da Terapia a Laser de Baixa Intensidade isolada e associada ao óleo de Calendula officinalis no reparo de úlceras em pé diabético. Estudo de caso clínico, experimental, controlado, randomizado, prospectivo, intervencional, de caráter quantitativo. A amostra foi composta de 32 pacientes diabéticos, de ambos os gêneros. Os participantes foram distribuídos aleatoriamente em quatro grupos. Ultrassom Doppler, avaliação do Índice Tornozelo-Braquial, Inventário breve de dor e escala de dor analógica foram realizados no início e após 30 dias. Houve redução da dor nos grupos Terapia a Laser de Baixa Intensidade e Terapia a Laser de Baixa intensidade associada aos Ácidos Graxos Essenciais, com p<0,01. Quanto ao Índice Tornozelo-Braquial e Ultrassom Doppler, todos os grupos mantiveram-se estáveis. Na análise da redução de área da lesão, o grupo Terapia a Laser de Baixa Intensidade associada aos Ácidos Graxos Essenciais apresentou uma significância p=0,0032, e o grupo Terapia a Laser de Baixa Intensidade, p=0,0428. A Terapia a Laser de Baixa Intensidade, realizada tanto isoladamente quanto associada ao óleo de Calendula officinalis, foi eficaz no alívio da dor e na aceleração do processo de reparo tecidual de pé diabético.
Hopster, Klaus; Wittenberg-Voges, Liza; Kästner, Sabine B.R.
2017-01-01
To investigate the effects of a xylazine infusion during isoflurane anesthesia on global perfusion parameters and gastrointestinal oxygenation and microperfusion, 8 adult warmblood horses were sedated with xylazine and anesthesia induced with midazolam and ketamine. Horses were mechanically ventilated during anesthesia. After 3 h of stable isoflurane anesthesia (FEIso 1.3 Vol %), a xylazine infusion with 1 mg/kg body weight (BW) per hour was started for 1 h and then stopped. Before, during, and after xylazine infusion, heart rate (HR), arterial blood pressure (MAP), cardiac output (CO), central venous pressure (CVP), and pulmonary artery pressure (PAP) were measured and systemic vascular resistance (SVR) was calculated. Arterial blood gases were taken and oxygen delivery (DO2) and alveolar dead space (VDalv) were calculated. Further intestinal oxygen and microperfusion were measured using white light spectroscopy and laser Doppler flowmetry. Surface probes were placed via median laparotomy on the stomach, the jejunum, and the colon. Wilcoxon rank-sum test was used to compare values over time (P < 0.05). During xylazine infusion, MAP, CVP, PAP, SVR, and VDalv increased significantly, whereas CO, DO2, and intestinal microperfusion decreased. Intestinal oxygenation remained unchanged. All parameters returned to pre-xylazine values within 1 h after stopping xylazine infusion. A xylazine infusion during constant isoflurane anesthesia in horses impairs global and intestinal perfusion without changing tissue oxygenation in normoxic healthy horses. Further studies are necessary, however, to evaluate whether a possible reduction of isoflurane concentration by xylazine infusion will ameliorate these negative effects. PMID:29081581
Percutaneous window chamber method for chronic intravital microscopy of sensor-tissue interactions.
Koschwanez, Heidi E; Klitzman, Bruce; Reichert, W Monty
2008-11-01
A dorsal, two-sided skin-fold window chamber model was employed previously by Gough in glucose sensor research to characterize poorly understood physiological factors affecting sensor performance. We have extended this work by developing a percutaneous one-sided window chamber model for the rodent dorsum that offers both a larger subcutaneous area and a less restrictive tissue space than previous animal models. A surgical procedure for implanting a sensor into the subcutis beneath an acrylic window (15 mm diameter) is presented. Methods to quantify changes in the microvascular network and red blood cell perfusion around the sensors using noninvasive intravital microscopy and laser Doppler flowmetry are described. The feasibility of combining interstitial glucose monitoring from an implanted sensor with intravital fluorescence microscopy was explored using a bolus injection of fluorescein and dextrose to observe real-time mass transport of a small molecule at the sensor-tissue interface. The percutaneous window chamber provides an excellent model for assessing the influence of different sensor modifications, such as surface morphologies, on neovascularization using real-time monitoring of the microvascular network and tissue perfusion. However, the tissue response to an implanted sensor was variable, and some sensors migrated entirely out of the field of view and could not be observed adequately. A percutaneous optical window provides direct, real-time images of the development and dynamics of microvascular networks, microvessel patency, and fibrotic encapsulation at the tissue-sensor interface. Additionally, observing microvessels following combined bolus injections of a fluorescent dye and glucose in the local sensor environment demonstrated a valuable technique to visualize mass transport at the sensor surface.
Optical assessment of intravascular and intracellular parameters related to tissue viability
NASA Astrophysics Data System (ADS)
Mayevsky, Avraham; Sherman, Efrat; Cohen-Kashi, Meir; Dekel, Nava; Pewzner, Eliyahu
2007-02-01
Tissue viability represents the balance between O II supply and demand. In our previous paper (Mayevsky et al; Proc.SPIE 6083 : z1-z10, 2006) the HbO II was added to the multiparametric tissue spectroscope (Mayevsky et al J.Biomedical Optics 9:1028-1045,2004). This parameter provides relative values of microcirculatory blood oxygenation (MC-HbO II) evaluated by the 2 wavelength reflectometry principle. The advantage of this approach as compared to pulse oximetry is that the measurement is not dependent of the existence of the pulse of the heart. Also in the MC-HbO II the information is collected from small vessels providing O II to the mitochondria as compared to the pulse oximeter indicating blood oxygenation by the respiratory and cardiovascular systems. In the present study we compared the level of blood oxygenation measured by the pulse oximeter to that measured by the CritiView in the brain exposed to various systemic and localized perturbations of O II supply or demand. We exposed gerbils to anoxia, hypoxia, ischemia and terminal anoxia. In addition we measured mitochondrial NADH (surface fluorometry), tissue reflectance, tissue blood flow (laser Doppler flowmetry) from the same site of MC-HbO II measurement. A clear connection was found between the two blood oxygenation parameters only when systemic perturbations were used (anoxia, hypoxia and terminal anoxia). Under local events (ischemia) the MC-HbO II was responsive while the systemic oxygenation was unchanged. We concluded that MC-HbO II has a significant value in interpretation of tissue energy metabolism under pathophysiological conditions.
Bioactive nitric oxide concentration does not increase during reactive hyperemia in human skin.
Zhao, J L; Pergola, P E; Roman, L J; Kellogg, D L
2004-02-01
This study examined whether nitric oxide (NO) is involved in the cutaneous response to reactive hyperemia (RH) in the human forearm. We enrolled seven healthy volunteers. NO concentrations were monitored using a NO selective amperometric electrode (ISO-NOP200, World Precision Instruments) inserted into the skin of the forearm. Laser-Doppler flowmetry (Moor Instruments) was used for monitoring skin blood flow (SkBF) at the same site. SkBF and NO levels were monitored and recorded continuously throughout the experiment. An intradermal microdialysis probe was inserted adjacent to the NO electrode for drug delivery. Data collection began 140 min after the NO electrodes and microdialysis probes were inserted. RH was achieved by the inflation of a blood pressure cuff to 25 mmHg above systolic pressure for 7 min after which the pressure in the cuff was abruptly released. Acetylcholine (ACh) was given by microdialysis probe at the end of RH study to verify the ability of the electrode system to detect changes in the NO concentration. SkBF and NO data before RH and immediately, 2, 5, 7, and 10 min after cuff deflation were used for analysis. SkBF increased immediately after release of the occlusion (P < 0.0001) and remained elevated for 2 min. No significant NO changes occurred with the increases in LDF. ACh induced increases in both SkBF and NO (P < 0.000 and P < 0.037, respectively). We conclude that RH increases SkBF by mechanisms that do not require a measurable increase in NO concentrations.
Evidence that the human cutaneous venoarteriolar response is not mediated by adrenergic mechanisms
NASA Technical Reports Server (NTRS)
Crandall, C. G.; Shibasaki, M.; Yen, T. C.
2002-01-01
The venoarteriolar response causes vasoconstriction to skin and muscle via local mechanisms secondary to venous congestion. The purpose of this project was to investigate whether this response occurs through alpha-adrenergic mechanisms. In supine individuals, forearm skin blood flow was monitored via laser-Doppler flowmetry over sites following local administration of terazosin (alpha(1)-antagonist), yohimbine (alpha(2)-antagonist), phentolamine (non-selective alpha-antagonist) and bretylium tosylate (inhibits neurotransmission of adrenergic nerves) via intradermal microdialysis or intradermal injection. In addition, skin blood flow was monitored over an area of forearm skin that was locally anaesthetized via application of EMLA (2.5 % lidocaine (lignocaine) and 2.5 % prilocaine) cream. Skin blood flow was also monitored over adjacent sites that received the vehicle for the specified drug. Each trial was performed on a minimum of seven subjects and on separate days. The venoarteriolar response was engaged by lowering the subject's arm from heart level such that the sites of skin blood flow measurement were 34 +/- 1 cm below the heart. The arm remained in this position for 2 min. Selective and non-selective alpha-adrenoceptor antagonism and presynaptic inhibition of adrenergic neurotransmission did not abolish the venoarteriolar response. However, local anaesthesia blocked the venoarteriolar response without altering alpha-adrenergic mediated vasoconstriction. These data suggest that the venoarteriolar response does not occur through adrenergic mechanisms as previously reported. Rather, the venoarteriolar response may due to myogenic mechanisms associated with changes in vascular pressure or is mediated by a non-adrenergic, but neurally mediated, local mechanism.
Ogata, Junichi; Minami, Kouichiro; Segawa, Kayoko; Uezono, Yasuhito; Shiraishi, Munehiro; Yamamoto, Chikako; Sata, Takeyoshi; Sung-Teh, Kim; Shigematsu, Akio
2004-01-01
A forskolin derivative, colforsin daropate hydrochloride (CDH), acts directly on adenylate cyclase to increase the intracellular cyclic adenosine monophosphate levels which produce a positive inotropic effect and a lower blood pressure. However, little is known about the effects of CDH on the renal function. We used laser Doppler flowmetry to measure the cortical renal blood flow (RBF) in male Wistar rats given a continuous intravenous infusion of CDH and evaluated the effects of CDH on the noradrenaline (NA) and angiotensin II (AngII) induced increases in blood pressure and reductions in RBF. Continuous intravenous administration of CDH at 0.25 microg/kg/min did not affect the mean arterial pressure (MAP), but increased heart rate and RBF. Continuous intravenous administration of CDH at high doses (0.5-0.75 microg/kg/min) decreased the MAP, with little effect on the RBF. The administration of exogenous NA (1.7 microg/kg) increased the MAP and decreased the RBF. However, a bolus injection of NA did not decrease the RBF during continuous intravenous administration of CDH, and CDH did not affect the NA-induced increase in MAP. The administration of exogenous AngII (100 ng/kg) increased MAP and decreased RBF and heart rate, but a bolus injection of AngII did not decrease RBF during continuous intravenous administration of CDH. These results suggest that CDH plays a protective role against the pressor effects and the decrease in RBF induced by NA or AngII. Copyright 2004 S. Karger AG, Basel
NASA Astrophysics Data System (ADS)
Barbiro-Michaely, Efrat; Arnon, Hana; Mayevsky, Avraham
2008-12-01
The use of retractors is essential in many neurosurgical procedures however, substantial evidence indicates that the use of retractors induce contusion and infraction of the retracted tissue and adjacent regions. The main effect of retraction involved a clear decreased tissue blood flow and oxygenation and a decrease in energy production. In this study we tested the effects of retraction injury in a rat model related to several aspects. We tested the effect of duration and intensity of retraction as well as compared continuous versus intermittent retraction. In order to evaluate the hemodynamic and metabolic condition of the retracted tissue, a unique multiparametric monitoring probe (MPA) was used. This probe contained optical fibers for microcirculatory blood flow (CBF) monitoring by laser Doppler flowmetry and fibers for NADH fluorometry. Additionally, the MPA contains a Camino probe for intracranial pressure (ICP) monitoring, mini-electrode for K+ extracellular level monitoring surrounded by a DC-potential electrode and ECoG electrodes. Our preliminary results showed that retraction which induced an initial ICP pressure of 25mmHg, yielded only minor and reversible changes in cerebral metabolism whereas a pressure of 50mmHg caused a significant decrease in CBF, elevation of NADH and extracellular level of K+. In the intermittent retraction model the negative effect on the cerebral tissue was significantly larger than that of the single continuous retraction model. In conclusion, the use of the MPA for the evaluation of retraction induce injury, may reveal new insights into the damage developed in the brain.
Aggravated brain damage after hypoxic ischemia in immature adenosine A2A knockout mice.
Adén, Ulrika; Halldner, Linda; Lagercrantz, Hugo; Dalmau, Ishar; Ledent, Catherine; Fredholm, Bertil B
2003-03-01
Cerebral hypoxic ischemia (HI) is an important cause of brain injury in the newborn infant. Adenosine is believed to protect against HI brain damage. However, the roles of the different adenosine receptors are unclear, particularly in young animals. We examined the role of adenosine A2A receptors (A2AR) using 7-day-old A2A knockout (A2AR(-/-)) mice in a model of HI. HI was induced in 7-day-old CD1 mice by exposure to 8% oxygen for 30 minutes after occlusion of the left common carotid artery. The resulting unilateral focal lesion was evaluated with the use of histopathological scoring and measurements of residual brain areas at 5 days, 3 weeks, and 3 months after HI. Behavioral evaluation of brain injury by locomotor activity, rotarod, and beam-walking test was made 3 weeks and 3 months after HI. Cortical cerebral blood flow, assessed by laser-Doppler flowmetry, and rectal temperature were measured during HI. Reduction in cortical cerebral blood flow during HI and rectal temperature did not differ between wild-type (A2AR(+/+)) and knockout mice. In the A2AR(-/-) animals, brain injury was aggravated compared with wild-type mice. The A2AR(-/-) mice subjected to HI displayed increased forward locomotion and impaired rotarod performance in adulthood compared with A2AR(+/+) mice subjected to HI, whereas beam-walking performance was similarly defective in both groups. These results suggest that, in contrast to the situation in adult animals, A2AR play an important protective role in neonatal HI brain injury.
Park, Eunkuk; Lee, Gi-Ja; Choi, Samjin; Choi, Seok-Keun; Chae, Su-Jin; Kang, Sung-Wook; Pak, Youngmi Kim; Park, Hun-Kuk
2010-01-01
Voltage-dependent anion channel (VDAC) is the main protein in mitochondria-mediated apoptosis, and the modulation of VDAC may be induced by the excessive release of extracellular glutamate. This study examined the role of glutamate release on VDAC-mediated apoptosis in an eleven vessel occlusion model in rats. Male Sprague-Dawley rats (250–350 g) were used for the 11 vessel occlusion ischemic model, which were induced for a 10-min transient occlusion. During the ischemic and initial reperfusion episode, the real-time monitoring of the extracellular glutamate concentration was measured using an amperometric microdialysis biosensor and the cerebral blood flow (CBF) was monitored by laser-Doppler flowmetry. To confirm neuronal apoptosis, the brains were removed 72 h after ischemia to detect the neuron-specific nuclear protein and pro-apoptotic proteins (cleaved caspase-3, VDAC, p53 and BAX). The changes in the mitochondrial morphology were measured by atomic force microscopy. A decrease in the % of CBF was observed, and an increase in glutamate release was detected after the onset of ischemia, which continued to increase during the ischemic period. A significantly higher level of glutamate release was observed in the ischemia group. The increased glutamate levels in the ischemia group resulted in the activation of VDAC and pro-apoptotic proteins in the hippocampus with morphological alterations to the mitochondria. This study suggests that an increase in glutamate release promotes VDAC-mediated apoptosis in an 11 vessel occlusion ischemic model. PMID:21203570
Song, Jin-Ning; Chen, Hu; Zhang, Ming; Zhao, Yong-Lin; Ma, Xu-Dong
2013-03-01
Regional cerebral blood flow (rCBF) in the cerebral metabolism and energy metabolism measurements can be used to assess blood flow of brain cells and to detect cell activity. Changes of rCBF in the cerebral microcirculation and energy metabolism were determined in an experimental model of subarachnoid hemorrhage (SAH) model in 56 large-eared Japanese rabbits about 12 to 16-month old. Laser Doppler flowmetry was used to detect the blood supply to brain cells. Internal carotid artery and vein blood samples were used for duplicate blood gas analysis to assess the energy metabolism of brain cells. Cerebral blood flow (CBF) was detected by single photon emission computed tomography (SPECT) perfusion imaging using Tc-99m ethyl cysteinate dimer (Tc-99m ECD) as an imaging reagent. The percentage of injected dose per gram of brain tissue was calculated and analyzed. There were positive correlations between the percentage of radionuclide injected per gram of brain tissue and rCBF supply and cerebral metabolic rate for oxygen (P < 0.05). However, there was a negative correlation between radioactivity counts per unit volume detected on the SPECT rheoencephalogram and lactic acid concentration in the homolateral internal carotid artery and vein. In summary, this study found abnormal CBF in metabolism and utilization of brain cells after SAH, and also found that deterioration of energy metabolism of brain cells played a significant role in the development of SAH. There are matched reductions in CBF and metabolism. Thus, SPECT imaging could be used as a noninvasive method to detect CBF.
Zeng, Yaping; Deyo, Donald; Parsley, Margaret A.; Hawkins, Bridget E.; Prough, Donald S.; DeWitt, Douglas S.
2018-01-01
Abstract To determine the effects of mild blast-induced traumatic brain injury (bTBI), several groups of rats were subjected to blast injury or sham injury in a compressed air-driven shock tube. The effects of bTBI on relative cerebral perfusion (laser Doppler flowmetry [LDF]), and mean arterial blood pressure (MAP) cerebral vascular resistance were measured for 2 h post-bTBI. Dilator responses to reduced intravascular pressure were measured in isolated middle cerebral arterial (MCA) segments, ex vivo, 30 and 60 min post-bTBI. Neuronal injury was assessed (Fluoro-Jade C [FJC]) 24 and 48 h post-bTBI. Neurological outcomes (beam balance and walking tests) and working memory (Morris water maze [MWM]) were assessed 2 weeks post-bTBI. Because impact TBI (i.e., non-blast TBI) is often associated with reduced cerebral perfusion and impaired cerebrovascular function in part because of the generation of reactive oxygen and nitrogen species such as peroxynitrite (ONOO−), the effects of the administration of the ONOO− scavenger, penicillamine methyl ester (PenME), on cerebral perfusion and cerebral vascular resistance were measured for 2 h post-bTBI. Mild bTBI resulted in reduced relative cerebral perfusion and MCA dilator responses to reduced intravascular pressure, increases in cerebral vascular resistance and in the numbers of FJC-positive cells in the brain, and significantly impaired working memory. PenME administration resulted in significant reductions in cerebral vascular resistance and a trend toward increased cerebral perfusion, suggesting that ONOO− may contribute to blast-induced cerebral vascular dysfunction. PMID:29160141
Over-vibration induced blood perfusion and vascular permeability changes may lead to vocal edema.
Wang, Jiajia; Devine, Erin; Fang, Rui; Jiang, Jack J
2017-01-01
To observe blood perfusion and vascular permeability changes under varying vibration frequency exposures. Animal model. Blood perfusion was measured using laser Doppler flowmetry in eight rabbit auricular vessels (four rabbits) under nonvibration, and 62.5-Hz/1-mm, 125-Hz/1-mm, and 250-Hz/0.5-mm vibration frequency/amplitude exposures. Another 12 rabbits were randomly divided into vibration only and vibration with histamine groups. After 3 hours of continuous 125-Hz, 1-mm amplitude vibration of the auricle, vascular permeability was analyzed by absorbance of Evans blue-albumin complex. Significantly lower blood perfusion was observed in the vibration group, compared with no vibration exposure controls. Blood perfusion decreased 29 ± 16% as the vibration frequency was increased from 62.5 Hz to 125 Hz with the vibration amplitude constant at 1 mm. When the frequency was increased from 125 Hz to 250 Hz, while the amplitude was decreased from 1 mm to 0.5 mm, blood flow perfusion further decreased 29 ± 29%, and the decline tendency in blood perfusion showed no significant difference (P = .992). Meanwhile, in the vibration with histamine group, vascular permeability of the vibrated ears increased significantly compared to the nonvibrated ears (P = .005). Overvibration of the vocal folds due to voice overuse or abuse may significantly reduce blood perfusion, and increase vascular permeability in the vocal fold in inflammatory situations, which may lead to the formation of vocal edema. NA Laryngoscope, 127:148-152, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
NASA Astrophysics Data System (ADS)
Dunaev, Andrey V.; Sidorov, Victor V.; Krupatkin, Alexander I.; Rafailov, Ilya E.; Palmer, Scott G.; Sokolovski, Sergei G.; Stewart, Neil A.; Rafailov, Edik U.
2014-02-01
Multi-functional laser non-invasive diagnostic systems, such as "LAKK-M", allow the study of a number of microcirculatory parameters, including blood microcirculatory index (Im) (by laser Doppler flowmetry, LDF) and oxygen saturation (StO2) of skin tissue (by tissue reflectance oximetry, TRO). Such systems may provide significant information relevant to physiology and clinical medicine. The aim of this research was to use such a system to study the synchronization of microvascular blood flow and oxygen saturation rhythms under normal and adaptive change conditions. Studies were conducted with 8 healthy volunteers - 3 females and 5 males of 21-49 years. Each volunteer was subjected to basic 3 minute tests. The volunteers were observed for between 1-4 months each, totalling 422 basic tests. Measurements were performed on the palmar surface of the right middle finger and the forearm medial surface. Wavelet analysis was used to study rhythmic oscillations in LDF- and TRO-data. Tissue oxygen consumption (from arterial and venal blood oxygen saturation and nutritive flux volume) was calculated for all volunteers during "adaptive changes" as (617+/-123 AU) and (102+/-38 AU) with and without arteriovenous anastomoses (AVAs) respectively. This demonstrates increased consumption compared to normal (495+/-170 AU) and (69+/-40 AU) with and without AVAs respectively. Data analysis demonstrated the emergence of resonance and synchronization of rhythms of microvascular blood flow and oxygen saturation as an adaptive change in myogenic oscillation (vasomotion) resulting from exercise and potentially from psychoemotional stress. Synchronization of myogenic rhythms during adaptive changes suggest increased oxygen consumption resulting from increased microvascular blood flow velocity.
NASA Astrophysics Data System (ADS)
Casper, Malte; Schulz-Hildebrandt, Hinnerk; Evers, Michael; Nguyen, Cuc; Birngruber, Reginald; Hüttmann, Gereon; Manstein, Dieter
2017-02-01
In dermatology the reflexes of vasoconstriction and vasodilation are known as important mechanisms of thermoregulation of the inner body. Imaging the physiology of microvasculature of the skin with high spatial resolution in three dimensions while reacting to changes in temperature is crucial for understanding the complex processes of vasodynamics, which result in constriction and dilation of vessels. However, previous studies using Laser-Doppler flowmetry and -imaging could not provide reliable angiographic images which allow to quantify changes in blood vessel diameter. Here, we report a different approach for angiographic imaging of microvasculature of a anaesthetized rodent model using speckle variance optical coherence tomography (svOCT) during and after localized cooling. Therefore a commercial OCT with a center wavelength of 1.3 μm and a spatial resolution of 13µm was used in combination with a custom built cooling device to image such reflexes at the mouse ear pinna and dorsal skinfold. Cooling was applied in steps of 2-5° C starting at the baseline temperature of 27° C down to -10° C. To our surprise and in contrast to the general opinion in literature, we were able to observe that the majority of vessels with a diameter larger than 20 μm maintain perfused with a constant diameter when the tissue is cooled from baseline to subzero temperatures. However, vasoconstriction was observed very rarely and only in veins, which led to their occlusion. The results of this experiment lead us to reconsider essential aspects of previous understanding of temperature-induced vasodynamics in cutaneous microvasculature.
Aspergillus fumigatus Invasion Increases with Progressive Airway Ischemia
Hsu, Joe L.; Khan, Mohammad A.; Sobel, Raymond A.; Jiang, Xinguo; Clemons, Karl V.; Nguyen, Tom T.; Stevens, David A.; Martinez, Marife; Nicolls, Mark R.
2013-01-01
Despite the prevalence of Aspergillus-related disease in immune suppressed lung transplant patients, little is known of the host-pathogen interaction. Because of the mould’s angiotropic nature and because of its capacity to thrive in hypoxic conditions, we hypothesized that the degree of Aspergillus invasion would increase with progressive rejection-mediated ischemia of the allograft. To study this relationship, we utilized a novel orthotopic tracheal transplant model of Aspergillus infection, in which it was possible to assess the effects of tissue hypoxia and ischemia on airway infectivity. Laser Doppler flowmetry and FITC-lectin were used to determine blood perfusion, and a fiber optic microsensor was used to measure airway tissue oxygen tension. Fungal burden and depth of invasion were graded using histopathology. We demonstrated a high efficacy (80%) for producing a localized fungal tracheal infection with the majority of infection occurring at the donor-recipient anastomosis; Aspergillus was more invasive in allogeneic compared to syngeneic groups. During the study period, the overall kinetics of both non-infected and infected allografts was similar, demonstrating a progressive loss of perfusion and oxygenation, which reached a nadir by days 10-12 post-transplantation. The extent of Aspergillus invasion directly correlated with the degree of graft hypoxia and ischemia. Compared to the midtrachea, the donor-recipient anastomotic site exhibited lower perfusion and more invasive disease; a finding consistent with clinical experience. For the first time, we identify ischemia as a putative risk factor for Aspergillus invasion. Therapeutic approaches focused on preserving vascular health may play an important role in limiting Aspergillus infections. PMID:24155924
Is there a stimulation of blood microcirculation at low level laser irradiation
NASA Astrophysics Data System (ADS)
Rogatkin, Dmitry; Dunaev, Andrey
2014-05-01
In 1980-2000 besides the laser surgery an intensive evolution of Low Level Laser Therapy (LLLT) had started in medicine, especially in Russia as well as in several other East-European countries. At the same time the biophysical mechanisms of LLLT are still the subject of disputes. One of the most popular clinical effects at Low Level Laser Irradiation (LLLI) being mentioned in medical publications for justification of the LLLT healing outcome is a stimulation of blood microcirculation in irradiated area. It was declared a priori at a dawn of LLLT and is now a basis of medical interpretation of healing mechanisms of LLLT at least in Russia. But in past 20 years a lot of investigation was carried out on optical registration of microhaemodynamic parameters in vivo as well as a number of noninvasive diagnostic tools was created for that. So, today it is possible to experimentally check the blood microcirculation stimulation hypothesis. Our study was aimed on that during the past 10 years. The most precision and accurate experiments we have carried out recently using simultaneously three different noninvasive diagnostic techniques: Laser Doppler Flowmetry, Tissue Reflectance Oximetry and Infrared Thermography. All these methods didn't confirm the effect on the blood microcirculation stimulation in skin or mucosa at irradiation with the power density below 50 mW/cm2 and irradiation time up to 5-6 minutes. Above this threshold the heating on 0,8…1 °C of tissue in the field of irradiation and the corresponding synchronous increase of all parameters of microhemodynamics were observed.
Neuroprotective effect of curcumin on okadaic acid induced memory impairment in mice.
Rajasekar, N; Dwivedi, Subhash; Tota, Santosh Kumar; Kamat, Pradeep Kumar; Hanif, Kashif; Nath, Chandishwar; Shukla, Rakesh
2013-09-05
Okadaic acid (OKA) has been observed to cause memory impairment in human subjects having seafood contaminated with dinoflagellate (Helicondria okadai). OKA induces tau hyperphosphorylation and oxidative stress leading to memory impairment as our previous study has shown. Curcumin a natural antioxidant has demonstrated neuroprotection in various models of neurodegeneration. However, the effect of curcumin has not been explored in OKA induced memory impairment. Therefore, present study evaluated the effect of curcumin on OKA (100ng, intracerebrally) induced memory impairment in male Swiss albino mice as evaluated in Morris water maze (MWM) and passive avoidance tests (PAT). OKA administration resulted in memory impairment with a decreased cerebral blood flow (CBF) (measured by laser doppler flowmetry), ATP level and increased mitochondrial (Ca(2+))i, neuroinflammation (increased TNF-α, IL-1β, COX-2 and GFAP), oxidative-nitrosative stress, increased Caspase-9 and cholinergic dysfunction (decreased AChE activity/expression and α7 nicotinic acetylcholine receptor expression) in cerebral cortex and hippocampus of mice brain. Oral administration of curcumin (50mg/kg) for 13 days significantly improved memory function in both MWM and PAT along with brain energy metabolism, CBF and cholinergic function. It decreased mitochondrial (Ca(2+))i, and ameliorated neuroinflammation and oxidative-nitrostative stress in different brain regions of OKA treated mice. Curcumin also inhibited astrocyte activation as evidenced by decreased GFAP expression. This neuroprotective effect of curcumin is due to its potent anti-oxidant action thus confirming previous studies. Therefore, use of curcumin should be encouraged in people consuming sea food (contaminated with dinoflagellates) to prevent cognitive impairment. © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liao, Fuyuan; O'Brien, William D.; Jan, Yih-Kuen
2013-10-01
The objective of this study was to investigate the effects of local heating on the complexity of skin blood flow oscillations (BFO) under prolonged surface pressure in rats. Eleven Sprague-Dawley rats were studied: 7 rats underwent surface pressure with local heating (△t=10 °C) and 4 rats underwent pressure without heating. A pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin blood flow was measured using laser Doppler flowmetry. The loading period was divided into nonoverlapping 30 min epochs. For each epoch, multifractal detrended fluctuation analysis (MDFA) was utilized to compute DFA coefficients and complexity of endothelial related metabolic, neurogenic, and myogenic frequencies of BFO. The results showed that under surface pressure, local heating led to a significant decrease in DFA coefficients of myogenic frequency during the initial epoch of loading period, a sustained decrease in complexity of myogenic frequency, and a significantly higher degree of complexity of metabolic frequency during the later phase of loading period. Surrogate tests showed that the reduction in complexity of myogenic frequency was associated with a loss of nonlinearity whereas increased complexity of metabolic frequency was associated with enhanced nonlinearity. Our results indicate that increased metabolic activity and decreased myogenic response due to local heating manifest themselves not only in magnitudes of metabolic and myogenic frequencies but also in their structural complexity. This study demonstrates the feasibility of using complexity analysis of BFO to monitor the ischemic status of weight-bearing skin and risk of pressure ulcers.
Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H
1998-01-01
To determine whether prolonged (chronic) resuscitation has any beneficial effects on cardiac output and hepatocellular function after trauma-hemorrhage and acute fluid replacement. Acute fluid resuscitation after trauma-hemorrhage restores but does not maintain the depressed hepatocellular function and cardiac output. Male Sprague-Dawley rats underwent a 5-cm laparotomy (i.e., trauma was induced) and were bled to and maintained at a mean arterial pressure of 40 mmHg until 40% of maximal bleed-out volume was returned in the form of Ringer's lactate (RL). The animals were acutely resuscitated with RL using 4 times the volume of maximum bleed-out over 60 minutes, followed by chronic resuscitation of 0, 5, or 10 mL/kg/hr RL for 20 hours. Hepatocellular function was determined by an in vivo indocyanine green clearance technique. Hepatic microvascular blood flow was assessed by laser Doppler flowmetry. Plasma levels of interleukin-6 (IL-6) were determined by bioassay. Chronic resuscitation with 5 mL/kg/hr RL, but not with 0 or 10 mL/kg/hr RL, restored cardiac output, hepatocellular function, and hepatic microvascular blood flow at 20 hours after hemorrhage. The regimen above also reduced plasma IL-6 levels. Because chronic resuscitation with 5 mL/kg/hr RL after trauma-hemorrhage and acute fluid replacement restored hepatocellular function and hepatic microvascular blood flow and decreased plasma levels of IL-6, we propose that chronic fluid resuscitation in addition to acute fluid replacement should be routinely used in experimental studies of trauma-hemorrhage.
Muñoz-Hernandez, Rocio; Vallejo-Vaz, Antonio J; Sanchez Armengol, Angeles; Moreno-Luna, Rafael; Caballero-Eraso, Candela; Macher, Hada C; Villar, Jose; Merino, Ana M; Castell, Javier; Capote, Francisco; Stiefel, Pablo
2015-01-01
This study tries to assess the endothelial function in vivo using flow-mediated dilatation (FMD) and several biomarkers of endothelium formation/restoration and damage in patients with obstructive sleep apnoea (OSA) syndrome at baseline and after three months with CPAP therapy. Observational study, before and after CPAP therapy. We studied 30 patients with apnoea/hypopnoea index (AHI) >15/h that were compared with themselves after three months of CPAP therapy. FMD was assessed non-invasively in vivo using the Laser-Doppler flowmetry. Circulating cell-free DNA (cf-DNA) and microparticles (MPs) were measured as markers of endothelial damage and the vascular endothelial growth factor (VEGF) was determined as a marker of endothelial restoration process. After three month with CPAP, FMD significantly increased (1072.26 ± 483.21 vs. 1604.38 ± 915.69 PU, p< 0.005) cf-DNA and MPs significantly decreased (187.93 ± 115.81 vs. 121.28 ± 78.98 pg/ml, p<0.01, and 69.60 ± 62.60 vs. 39.82 ± 22.14 U/μL, p<0.05, respectively) and VEGF levels increased (585.02 ± 246.06 vs. 641.11 ± 212.69 pg/ml, p<0.05). These changes were higher in patients with more severe disease. There was a relationship between markers of damage (r = -0.53, p<0.005) but not between markers of damage and restoration, thus suggesting that both types of markers should be measured together. CPAP therapy improves FMD. This improvement may be related to an increase of endothelial restoration process and a decrease of endothelial damage.
Mechanisms of bee venom-induced acute renal failure.
Grisotto, Luciana S D; Mendes, Glória E; Castro, Isac; Baptista, Maria A S F; Alves, Venancio A; Yu, Luis; Burdmann, Emmanuel A
2006-07-01
The spread of Africanized bees in the American continent has increased the number of severe envenomation after swarm attacks. Acute renal failure (ARF) is one of the major hazards in surviving patients. To assess the mechanisms of bee venom-induced ARF, rats were evaluated before, up to 70 min and 24h after 0.5mg/kg of venom injection. Control rats received saline. Bee venom caused an early and significant reduction in glomerular filtration rate (GFR, inulin clearance, 0.84+/-0.05 to 0.40+/-0.08 ml/min/100g, p<0.0001) and renal blood flow (RBF, laser Doppler flowmetry), which was more severe in the cortical (-72%) than in the medullary area (-48%), without systemic blood pressure decrease. Creatine phosphokinase, lactic dehydrogenase (LDH) and serum glutamic oxaloacetic transaminase increased significantly, pointing to rhabdomyolysis, whereas serum glutamic pyruvic transaminase and hematocrit remained stable. Twenty-four hours after venom, RBF recovered but GFR remained significantly impaired. Renal histology showed acute tubular injury and a massive tubular deposition of myoglobin. Venom was added to isolated rat proximal tubules (PT) suspension subjected to normoxia and hypoxia/reoxygenation (H/R) for direct nephrotoxicity evaluation. After 60 min of incubation, 0.1, 2 and 10 microg of venom induced significant increases in LDH release: 47%, 64% and 86%, respectively, vs. 21% in control PT while 2 microg of venom enhanced H/R injury (85% vs. 55%, p<0.01). These results indicate that vasoconstriction, direct nephrotoxicity and rhabdomyolysis are important mechanisms in the installation of bee venom-induced ARF that may occur even without hemolysis or hypotension.
Stupin, Marko; Stupin, Ana; Rasic, Lidija; Cosic, Anita; Kolar, Luka; Seric, Vatroslav; Lenasi, Helena; Izakovic, Kresimir; Drenjancevic, Ines
2018-02-01
The effect of acute exhaustive exercise session on skin microvascular reactivity was assessed in professional rowers and sedentary subjects. A potential involvement of altered hemodynamic parameters and/or oxidative stress level in the regulation of skin microvascular blood flow by acute exercise were determined. Anthropometric, biochemical, and hemodynamic parameters were measured in 18 young healthy sedentary men and 20 professional rowers who underwent a single acute exercise session. Post-occlusive reactive hyperemia (PORH), endothelium-dependent acetylcholine (ACh), and endothelium-independent sodium nitroprusside (SNP) microvascular responses were assessed by laser Doppler flowmetry in skin microcirculation before and after acute exercise. Serum lipid peroxidation products and plasma antioxidant capacity were measured using spectrophotometry. At baseline, rowers had significantly lower diastolic blood pressure (DBP) and heart rate (HR), and higher stroke volume (SV), PORH, and endothelium-dependent vasodilation than sedentary. Acute exercise caused a significant increase in systolic blood pressure, DBP, HR, and SV and a decrease in total peripheral resistance in both groups. Acute exercise induced a significant impairment in PORH and ACh-induced response in rowers, but not in sedentary, whereas the SNP-induced vasodilation was not affected by acute exercise in any group. Antioxidant capacity significantly increased only in sedentary after acute exercise. Single acute exercise session impaired microvascular reactivity and endothelial function in rowers but not in sedentary, possibly due to (1) more rowing grades and higher exercise intensity achieved by rowers; (2) a higher increase in arterial pressure in rowers than in sedentary men; and (3) a lower antioxidant capacity in rowers.
NASA Astrophysics Data System (ADS)
Liu, Xudong; Zeng, Bingfang; Fan, Cunyi; Jiang, Peizhu; Hu, Xiao
2006-01-01
To find the properties in the oscillatory components of the cutaneous blood flow on the successful free flap, a wavelet transform was applied to the laser Doppler flowmetry (LDF) signals which were measured simultaneously on the surfaces of the free latissimus dorsi myocutaneous flap and on the adjacent intact skin of the healthy limb, of 18 patients. The frequency interval from 0.0095 to 1.6 Hz was examined and was divided into five subintervals (I: 0.0095-0.021 Hz; II: 0.021-0.052 Hz; III: 0.052-0.145 Hz; IV: 0.145-0.6 Hz and V: 0.6-1.6 Hz) corresponding to endothelial metabolic, neurogenic, myogenic, respiratory and cardiac origins. The average amplitude and total power in the frequency range 0.0095-1.6 Hz as well as within subintervals I, II, IV and V were significantly lower for signals measured on the free flap than those obtained in the healthy limb. However in interval III, they were significantly higher. The normalized spectral amplitude and power in the free flap were significantly lower in only two intervals, I and II, yet in interval III they were significantly higher; no statistical significance was observed in intervals IV and V. The distinctive finding made in this study, aside from the decrease of endothelial metabolic processes and sympathetic control, was the significant increase of myogenic activity in the free flap. It is hoped that this work will contribute towards knowledge on blood circulation in free flaps and make the monitoring by LDF more reliable.
Polska, Elzbieta; Simader, Christian; Weigert, Günter; Doelemeyer, Arno; Kolodjaschna, Julia; Scharmann, Ole; Schmetterer, Leopold
2007-08-01
To test the hypothesis that human choroidal blood flow (ChBF) may depend, not only on ocular perfusion pressure (OPP), but also on absolute mean arterial pressure (MAP) and intraocular pressure (IOP). There were two study days in an open design. On the first day, OPP was varied by elevating IOP during a squatting-induced increase in MAP (28 subjects). On the second day, only the IOP was increased (17 subjects). IOP was raised in stepwise increments by using the suction cup Subfoveal ChBF (laser Doppler flowmetry), MAP, and IOP were assessed, and OPP was calculated as (2/3)(MAP - IOP). For correlation analysis, data from all subjects were pooled according to IOP and MAP, and correlation analyses were performed. When data from study day 1 were grouped according to IOP, no correlation was observed between ChBF and MAP; but ChBFs were lower, the higher the IOP (P < 0.001). When data were grouped according to MAP, a significant correlation was found between ChBF and IOP (P < 0.001), but correlations were independent of MAP. When data of study day 2 were pooled according to IOP, a correlation between ChBF and OPP was seen only at IOP > 40 mm Hg (P < 0.05). The data confirm previously published observations that the choroid shows some autoregulatory capacity during changes in OPP. In addition, the data indicate that the choroid regulates its blood flow better during exercise-induced changes in MAP than during an experimental increase in IOP.
Polska, Elzbieta; Luksch, Alexandra; Ehrlich, Paulina; Sieder, Anna; Schmetterer, Leopold
2002-04-01
Two laser based methods for the assessment of ocular hemodynamics in humans have been investigated: laser Doppler flowmetry (LDF) and laser interferometric measurement of fundus pulsation amplitude (FPA). When the laser with either of the two methods is focused onto the fovea it is obvious that only choroidal blood flow contributes to the signals. When the laser is, however, directed to other parts of the retina the situation is more complex. Whereas the retina shows a pronounced vasoconstrictor response to systemic hyperoxia the effect in the choroid is small. We therefore investigated the effect of 100% O2 breathing on results as obtained with the above mentioned techniques at different fundus locations. Twelve healthy subjects were included. Four 15-minutes 100% O2 breathing periods were scheduled for each subject. During two of these breathing periods LDF was performed at the fovea (ChBFf) and at a fundus location approximately 7.5 degrees nasally to the fovea (ChBFp), respectively. During the other two periods FPA was assessed at the same fundus locations (FPAf, FPAp). ChBFf tended to decrease during 100% oxygen breathing (6 +/- 4%), but this effect was not significant. The decrease in ChBFp (10 +/- 4%), was comparable. FPAf (10 +/- 2%; P < 0.001) and FPAp (13 +/- 2%; P < 0.001) decreased significantly during systemic hyperoxia, but again there was no difference in the response obtained at the two fundus locations. When LDF and FPA are applied at the peripheral retina the obtained signal is mainly influenced by the choroidal circulation.
Posture changes and subfoveal choroidal blood flow.
Longo, Antonio; Geiser, Martial H; Riva, Charles E
2004-02-01
To evaluate the effect of posture change on subfoveal choroidal blood flow (ChBF) in normal volunteers. The pulsatile, nonpulsatile, and mean ChBF were measured with laser Doppler flowmetry in 11 healthy volunteers with a mean age of 32 +/- 13 (SD) years. The posture of the subjects was changed from standing (90 degrees ), to supine (-8 degrees ), and back to standing, with a mechanically driven table. During the whole experimental procedure, ChBF and heart rate (HR) were continuously recorded. After 30 seconds in standing position, the subjects were tilted to supine during approximately 30 seconds. They remained in this position for approximately 2 minutes, after which they were tilted back to the standing position (recovery), where they remained for another approximately 2 minutes. Systemic brachial artery blood pressure (BP) was measured in the baseline, supine, and recovery positions. This procedure was repeated to measure the intraocular pressure (IOP) at the different postures. Mean BP did not change significantly throughout the experimental procedure. As the body was tilted from standing to supine, HR decreased by 16% (P < 0.0004), IOP increased by 29% (P < 0.001), and mean ChBF increased by 11% (P < 0.01). The increase in ChBF was primarily due to an increase in the nonpulsatile component of the blood velocity. Based on previously reported experimental data that indicate that the ocular perfusion pressure increases less than predicted by purely hydrostatic considerations when the body is tilted from the standing to the supine position, the observed increase in ChBF suggests a passive response of the choroidal circulation to the posture change.
EFFECT OF PREGNANCY ON AUTOREGULATION OF CEREBRAL BLOOD FLOW IN ANTERIOR VERSUS POSTERIOR CEREBRUM
Cipolla, Marilyn J.; Bishop, Nicole; Chan, Siu-Lung
2012-01-01
Severe pre/eclampsia are associated with brain edema that forms preferentially in the posterior cerebral cortex possibly due to decreased sympathetic innervation of posterior cerebral arteries and less effective autoregulation during acute hypertension. In the present study, we examined the effect of pregnancy on the effectiveness of cerebral blood flow autoregulation using laser Doppler flowmetry and edema formation by wet:dry weight in acute hypertension induced by phenylephrine infusion in the anterior and posterior cerebrum from nonpregnant (n=8) and late-pregnant (n=6) Sprague Dawley rats. In addition, we compared the effect of pregnancy on sympathetic innervation by tyrosine hydroxylase staining of posterior and middle cerebral arteries (n=5–6/group) and endothelial and neuronal nitric oxide synthase expression using quantitative polymerase chain reaction (n=3/group). In nonpregnant animals, there was no difference in autoregulation between anterior and posterior cerebrum. However, in late-pregnant animals, the threshold of cerebral blood flow autoregulation was shifted to lower pressures in the posterior cerebrum, which was associated with increased neuronal nitric oxide synthase expression in the posterior cerebral cortex vs. anterior. Compared to the nonpregnant state, pregnancy increased the threshold of autoregulation in both brain regions that was related to decreased expression of endothelial nitric oxide synthase. Lastly, acute hypertension during pregnancy caused greater edema formation in both brain cortices that was not due to changes in sympathetic innervation. These findings suggest that although pregnancy shifted the cerebral blood flow autoregulatory curve to higher pressures in both the anterior and posterior cortices, it did not protect from edema during acute hypertension. PMID:22824983
Effect of pregnancy on autoregulation of cerebral blood flow in anterior versus posterior cerebrum.
Cipolla, Marilyn J; Bishop, Nicole; Chan, Siu-Lung
2012-09-01
Severe preeclampsia and eclampsia are associated with brain edema that forms preferentially in the posterior cerebral cortex possibly because of decreased sympathetic innervation of posterior cerebral arteries and less effective autoregulation during acute hypertension. In the present study, we examined the effect of pregnancy on the effectiveness of cerebral blood flow autoregulation using laser Doppler flowmetry and edema formation by wet:dry weight in acute hypertension induced by phenylephrine infusion in the anterior and posterior cerebrum from nonpregnant (n=8) and late-pregnant (n=6) Sprague-Dawley rats. In addition, we compared the effect of pregnancy on sympathetic innervation by tyrosine hydroxylase staining of posterior and middle cerebral arteries (n=5-6 per group) and endothelial and neuronal NO synthase expression using quantitative PCR (n=3 per group). In nonpregnant animals, there was no difference in autoregulation between the anterior and posterior cerebrum. However, in late-pregnant animals, the threshold of cerebral blood flow autoregulation was shifted to lower pressures in the posterior cerebrum, which was associated with increased neuronal NO synthase expression in the posterior cerebral cortex versus anterior. Compared with the nonpregnant state, pregnancy increased the threshold of autoregulation in both brain regions that was related to decreased expression of endothelial NO synthase. Lastly, acute hypertension during pregnancy caused greater edema formation in both brain cortices that was not attributed to changes in sympathetic innervation. These findings suggest that, although pregnancy shifted the cerebral blood flow autoregulatory curve to higher pressures in both the anterior and posterior cortices, it did not protect from edema during acute hypertension.
Dhanesha, Nirav; Vázquez-Rosa, Edwin; Cintrón-Pérez, Coral J; Thedens, Daniel; Kort, Alexa J; Chuong, Vicky; Rivera-Dompenciel, Adriana M; Chauhan, Anil K; Leira, Enrique C; Pieper, Andrew A
2018-05-01
Exogenous administration of uric acid, a naturally occurring antioxidant that scavenges reactive oxygen species in vasculature, has shown protective efficacy in both rodent models of stroke and human stroke patients in Spain as an adjuvant treatment to mechanical thrombectomy. Before clinical trials can be initiated in the United States, however, confirmation of efficacy in alternative preclinical models is required in accordance with stroke therapy academic industry roundtable-RIGOR criteria. To date, preclinical efficacy has only been established in the acute setting in male rodents. To address this need, we subjected 7- to 9-week old ovariectomized female mice to filament-induced right middle cerebral artery ischemia and reperfusion, an established preclinical model of mechanical thrombectomy. Fidelity of the procedure was monitored by laser Doppler flowmetry. A separate lab randomly assigned animals to vehicle versus uric acid infusion, which was initiated immediately after 45 minutes of reperfusion. Poststroke analysis of infarction size and neurologic function were conducted by investigators blind to treatment group, with a 7-day primary endpoint and a 3-day intermediary analysis at 1and. Infarct size and neurologic function at 7 days poststroke were significantly improved in uric acid-treated animals, relative to vehicle. Efficacy of uric acid in preclinical models of stroke is now expanded to include female mice analyzed at a later time point than has been investigated previously. These results support stroke therapy academic industry roundtable-RIGOR driven determination of the suitability of acute administration of uric acid as an adjuvant to mechanical thrombectomy in clinical trials for patients with stroke. Published by Elsevier Inc.
Schunke, Kathryn J.; Toung, Thomas K.; Zhang, Jian; Pathak, Arvind P.; Xu, Jiadi; Zhang, Jiangyang; Koehler, Raymond C.; Faraday, Nauder
2017-01-01
Background Most ischemic strokes in humans are caused by ruptured arterial atheroma, which activate platelets and produce thrombi that occlude cerebral vessels. Methods To simulate these events, we threaded a catheter through the internal carotid artery toward the middle cerebral artery (MCA) orifice and injected collagen directly into the cerebral circulation of male C57Bl/6 mice and Wistar rats. Results Laser-Doppler flowmetry demonstrated reductions in cerebral blood flow (CBF) of ~80% in mice and ~60% in rats. CBF spontaneously increased but remained depressed after catheter withdrawal. Magnetic resonance imaging showed that ipsilateral CBF was reduced at 3 h after collagen injection and markedly improved at 48 h. Micro-computed tomography revealed reduced blood vessel density in the ipsilateral MCA territory at 3 h. Gross examination of excised brains revealed thrombi within ipsilateral cerebral arteries at 3 h, but not 24 h, after collagen injection. Immunofluorescence microscopy confirmed that platelets and fibrinogen/fibrin were major components of these thrombi at both macrovascular and microvascular levels. Cerebral infarcts comprising ~30% of hemispheric volume and neurobehavioral deficits were observed 48 h after ischemic injury in both mice and rats. Comparison with existing methods Collagen injection caused brain injury that was similar in magnitude and variability to mechanical MCA occlusion or injection of a pre-formed clot; however, alterations in CBF and the mechanism of vascular occlusion were more consistent with clinical ischemic stroke. Conclusion This novel rodent model of ischemic stroke has pathophysiologic characteristics consistent with clinical atherothrombotic stroke, is technically feasible, and creates reproducible brain injury. PMID:25314906
Evaluation of accuracy, reliability, and repeatability of five dental pulp tests.
Chen, Eugene; Abbott, Paul V
2011-12-01
The aim of this study was to compare the clinical accuracy, reliability, and repeatability of laser Doppler flowmetry (LDF), an electric pulp test (EPT), and various thermal pulp sensibility tests. Pulp tests were done on 121 teeth in 20 subjects by using LDF, EPT, and thermal pulp testing (CO(2), Endo Frost [EF], Ice) during 2 or 3 test sessions with at least 1-week intervals. The order of testing was reversed on the second visit. A laser Doppler flowmeter was used to measure mean pulp blood flow (Flux) calibrated against a brownian motion medium and zeroed against a static reflector. The laser source was 780 nm, with 0.5-mm fiber separation in the probe, 3.1 kHz as the primary bandwidth for filter set to 0.1-second time output constant. Customized polyvinylsiloxane splints were fabricated for each participant, and a minimum of 90-second recording time was used for each tooth. Raw data were analyzed by using repeated measure analysis of variance, pairwise comparisons, and interclass correlations (ICC). The accuracy of EPT, CO(2), and LDF tests was 97.7%, 97.0%, and 96.3%, respectively, without significant differences (P > .3). Accuracy of EF and Ice was 90.7% and 84.8%, respectively. EPT (P = .015) and CO(2) (P = .022) were significantly more accurate than EF. LDF was more accurate than EF, but this was not statistically significant (P = .063). Ice was significantly less accurate than EPT (P = .004), CO(2) (P = .005), LDF (P = .006), and EF (P = .019). With the exception of Ice (effect of visit: F(2,38) = 5.67, mean squared error = 0.01, P = .007, η(2)(p) = 0.23), all tests were reliable. Ice (ICC = 0.677) and LDF (ICC = 0.654) were the most repeatable of the tests, whereas EPT (ICC = 0.434) and CO(2) (ICC = 0.432) were less repeatable. CO(2), EPT, and LDF were reliable and the most accurate tests, but CO(2) and EPT were less repeatable yet less time-consuming than LDF. EF was reliable but not as accurate as EPT and CO(2) and less repeatable than Ice and LDF. Ice was the most repeatable but the least accurate and least reliable test. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Tatarakis, Nikolaos; Gkranias, Nikolaos; Darbar, Ulpee; Donos, Nikolaos
2018-05-01
The study investigated the early healing process following the treatment of single Miller class I and II recessions with a 3D xenogeneic collagen matrix (CMX) or connective tissue graft (CTG). This pilot investigation was designed as a single-center randomized controlled parallel trial. A total of eight subjects (four per group) were treated with either CMX or CTG in the anterior maxilla. Vascular flow changes were assessed by laser Doppler flowmetry (LDF) before and after surgery and at days 1, 2, 3, 7, 14, and 30 while clinical evaluations took place at baseline and at days 60 and 180. Pain intensity perception was evaluated by the short-form McGill pain questionnaire (SF-MPQ), at days 1 and 14. The vascular flow fluctuated similarly in both groups pre- and post-operatively, but the CTG exhibited a more homogeneous pattern as opposed to CMX that showed a second phase of increased blood flow at 14 days. Clinically, the CTG led to greater change in mean root coverage and keratinized tissue gain but CMX was associated with lower early pain intensity scores. Within the limits of the study, the vascular flow alterations during the early healing of both graft types followed a similar pattern. The CMX was associated with a second peak of increased blood flow. The vascular flow changes after the application of CMX for single tooth recession root coverage did not show major differences from those observed after the use of a CTG. A trend for better clinical performance in terms of root coverage and keratinized tissue gain was noted for the CTG, but the initial patient morbidity was less for CMX.
Jones, Stephen C; Easley, Kirk A; Radinsky, Carol R; Chyatte, Douglas; Furlan, Anthony J; Perez-Trepichio, Alejandro D
2003-09-01
Variations in the height of the CBF response to hypotension have been described recently in normal animals. The authors evaluated the effects of nitric oxide synthase (NOS) inhibition on these variations in height using laser Doppler flowmetry in 42 anesthetized (halothane and N2O) male Sprague-Dawley rats prepared with a superfused closed cranial window. In four groups (time control, enantiomer control, NOS inhibition, and reinfusion control) exsanguination to MABPs from 100 to 40 mm Hg was used to produce autoregulatory curves. For each curve the lower limit of autoregulation (the MABP at the first decrease in CBF) was identified; the pattern of autoregulation was classified as "peak" (15% increase in %CBF), "classic" (plateau with a decrease at the lower limit of autoregulation), or "none" (15% decrease in %CBF); and the autoregulatory height as the %CBF at 70 mm Hg (%CBF(70)) was determined. NOS inhibition decreased %CBF(70) in the NOS inhibition group (P = 0.014), in the control (combined time and enantiomer control) group (P = 0.015), and in the reinfusion control group (P = 0.025). NOS inhibition via superfusion depressed the autoregulatory pattern (P = 0.02, McNemar test on changes in autoregulatory pattern) compared with control (P = 0.375). Analysis of covariance showed that changes induced by NOS inhibition in the parameters of autoregulatory height are not related to changes in the lower limit, but are strongly (P < 0.001) related to each other. NOS inhibition depressed the autoregulatory pattern, decreasing the seemingly paradoxical increase in CBF as blood pressure decreases. These results suggest that nitric oxide increases CBF near the lower limit and augments the hypotensive portion of the autoregulatory curve.
Neuronal nitric oxide synthase control mechanisms in the cutaneous vasculature of humans in vivo
Kellogg, Dean L; Zhao, Joan L; Wu, Yubo
2008-01-01
The physiological roles of constituitively expressed nitric oxide synthase (NOS) isoforms in humans, in vivo, are unknown. Cutaneous vasodilatation during both central nervous system-mediated, thermoregulatory reflex responses to whole-body heat stress and during peripheral axon reflex-mediated, local responses to skin warming in humans depend on nitric oxide (NO) generation by constituitively expressed NOS of uncertain isoform. We hypothesized that neuronal NOS (nNOS, NOS I) effects cutaneous vasodilatation during whole-body heat stress, but not during local skin warming. We examined the effects of the nNOS inhibitor 7-nitroindazole (7-NI) administered by intradermal microdialysis on vasodilatation induced by whole-body heat stress or local skin warming. Skin blood flow (SkBF) was monitored by laser–Doppler flowmetry (LDF). Blood pressure (MAP) was monitored and cutaneous vascular conductance calculated (CVC = LDF/MAP). In protocol 1, whole-body heat stress was induced with water-perfused suits. In protocol 2, local skin warming was induced through local warming units at LDF sites. At the end of each protocol, 56 mm sodium nitroprusside was perfused at microdialysis sites to raise SkBF to maximal levels for data normalization. 7-NI significantly attenuated CVC increases during whole-body heat stress (P < 0.05), but had no effect on CVC increases induced by local skin warming (P > 0.05). These diametrically opposite effects of 7-NI on two NO-dependent processes verify selective nNOS antagonism, thus proving that the nNOS isoform affects NO increases and hence vasodilatation during centrally mediated, reflex responses to whole-body heat stress, but not during locally mediated, axon reflex responses to local skin warming. We conclude that the constituitively expressed nNOS isoform has distinct physiological roles in cardiovascular control mechanisms in humans, in vivo. PMID:18048451
Bandier, J; Carlsen, B C; Rasmussen, M A; Petersen, L J; Johansen, J D
2015-06-01
Filaggrin is key for the integrity of the stratum corneum. Mutations in the filaggrin gene (FLGnull) play a prominent role in atopic dermatitis (AD) pathogenesis. People with AD have increased susceptibility to irritants. However, little is known about the effect of filaggrin genotype and AD phenotype on irritant response and skin regeneration. To investigate the role of FLGnull and AD groups for skin reaction and recovery after sodium lauryl sulfate (SLS) irritation. This is a case-control study comprising 67 subjects, including healthy controls and patients with and without FLGnull and AD. Reactivity to different doses of SLS at 24, 48, 72 and 145 h after SLS application was measured by transepidermal water loss (TEWL) and laser Doppler flowmetry (LDF). Reactivity was assessed univariately and by pattern analysis. All patient groups showed a higher degree of skin-barrier disruption and inflammation than did controls in response to SLS. Assessing reactivity by the delta value of the area under the curve for both TEWL and LDF showed significant differences between healthy controls and those with the AD phenotype, irrespective of filaggrin mutation. The poorest regeneration was among those with the AD phenotype. The two AD phenotype groups were separated by multivariate technique, due to earlier inflammatory reactivity among subjects with FLGnullplus AD compared with the AD phenotype alone. Both skin reaction and regeneration were significantly different between the patient population and the healthy controls. Additionally, response severity and regeneration depended more on AD phenotype than on filaggrin genotype, whereas the response was more rapid among the FLGnullplus AD individuals. © 2015 British Association of Dermatologists.
Combined facial heating and inhalation of hot air do not alter thermoeffector responses in humans.
Wingo, Jonathan E; Low, David A; Keller, David M; Kimura, Kenichi; Crandall, Craig G
2015-09-01
The influence of thermoreceptors in human facial skin on thermoeffector responses is equivocal; furthermore, the presence of thermoreceptors in the respiratory tract and their involvement in thermal homeostasis has not been elucidated. This study tested the hypothesis that hot air directed on the face and inhaled during whole body passive heat stress elicits an earlier onset and greater sensitivity of cutaneous vasodilation and sweating than that directed on an equal skin surface area away from the face. Six men and two women completed two trials separated by ∼1 wk. Participants were passively heated (water-perfused suit; core temperature increase ∼0.9°C) while hot air was directed on either the face or on the lower leg (counterbalanced). Skin blood flux (laser-Doppler flowmetry) and local sweat rate (capacitance hygrometry) were measured at the chest and one forearm. During hot-air heating, local temperatures of the cheek and leg were 38.4 ± 0.8°C and 38.8 ± 0.6°C, respectively (P = 0.18). Breathing hot air combined with facial heating did not affect mean body temperature onsets (P = 0.97 and 0.27 for arm and chest sites, respectively) or slopes of cutaneous vasodilation (P = 0.49 and 0.43 for arm and chest sites, respectively), or the onsets (P = 0.89 and 0.94 for arm and chest sites, respectively), or slopes of sweating (P = 0.48 and 0.65 for arm and chest sites, respectively). Based on these findings, respiratory tract thermoreceptors, if present in humans, and selective facial skin heating do not modulate thermoeffector responses during passive heat stress. Copyright © 2015 the American Physiological Society.
Maurer, C A; Renzulli, P; Baer, H U; Mettler, D; Uhlschmid, G; Neuenschwander, P; Suter, U W; Triller, J; Zimmermann, A
2000-02-01
In an attempt to overcome some of the problems encountered with the materials available for liver embolisation, we investigated a novel radiopaque polymer of the polyurethane family (Degra-Bloc). Hepatic artery embolisation of one liver lobe using polyurethane was performed in 19 healthy pigs. Microcirculatory changes were assessed by laser Doppler flowmetry. Radiological and pathological examinations of the livers, hearts and lungs removed provided information about the extent and effect of the embolisation. None of the pigs died due to hepatic failure or toxicity of polyurethane. Microcirculation of embolised liver lobes significantly decreased from 106 (+/-15) perfusion units (PU) to 45 (+/-6) PU immediately after embolisation and further to 28 (+/-7) PU before euthanasia. At this time conventional and angiographic X-ray controls demonstrated the radiopaque casts extending up to the peripheral arteries with signs of degradation over time but without formation of collateral vessels. The main pathological findings consisted of destruction of the portal tract structures and also of large areas of liver necrosis. Polyurethane was encountered in arterioles as small as 10-20 microm, but not in liver sinusoids, hearts or lungs. The novel polymer called DegraBloc is a biocompatible, slowly degradable, radiopaque embolic agent. The occlusion of the arterial tree up to the smallest arteriolar diameter combined with concomitant portal vein occlusion leads to sharp segmental necrosis in pig livers without formation of significant collaterals and without systemic embolism. In the treatment of liver tumours polyurethane might provide a promising alternative to conventional embolic materials, provided that it is used with care in patients with advanced liver cirrhosis.
Attenuation and recovery of brain stem autoregulation in spontaneously hypertensive rats.
Toyoda, K; Fujii, K; Ibayashi, S; Kitazono, T; Nagao, T; Takaba, H; Fujishima, M
1998-03-01
Cerebral large arteries dilate actively around the lower limits of CBF autoregulation, mediated at least partly by nitric oxide, and maintain CBF during severe hypotension. We tested the hypothesis that this autoregulatory response of large arteries, as well as the response of arterioles, is altered in spontaneously hypertensive rats (SHR) and that the altered response reverts to normal during long-term antihypertensive treatment with cilazapril, an angiotensin-converting enzyme inhibitor. In anesthetized 6- to 7-month-old normotensive Wistar-Kyoto rats (WKY), 4- and 6- to 7-month-old SHR without antihypertensive treatment, and 6- to 7-month-old SHR treated with cilazapril for 10 weeks, local CBF to the brain stem was determined with laser-Doppler flowmetry and diameters of the basilar artery and its branches were measured through a cranial window during stepwise hemorrhagic hypotension. The lower limit of CBF autoregulation shifted upward in untreated SHR to 90 to 105 mm Hg from 30 to 45 mm Hg in WKY, and it reverted to 30 to 45 mm Hg in treated SHR. In response to severe hypotension, the basilar artery dilated by 21 +/- 6% (mean +/- SD) of the baseline internal diameter in WKY. The vasodilation was impaired in untreated SHR (10 +/- 8% in 4-mo-old SHR and 4 +/- 5% in 6- to 7-month-old SHR), and was restored to 22 +/- 10% by treatment with cilazapril (P < 0.005). Dilator responses of branch arterioles to hypotension showed similar attenuation and recovery as that of the basilar artery. The data indicate that chronic hypertension impairs the autoregulatory dilation of the basilar artery as well as branch arterioles and that antihypertensive treatment with cilazapril restores the diminished dilation toward normal.
Pinto, Nelson; Harnish, Alexandra; Cabrera, Carolina; Andrade, Catherine; Druttman, Tony; Brizuela, Claudia
2017-11-01
Regenerative endodontic procedures (REPs) associated with apical surgery could represent an alternative treatment strategy for patients whose teeth present incomplete root formation and extensive apical lesions. Leukocyte platelet-rich fibrin (L-PRF) has potential benefits in REPs; it could promote apical root formation and optimal bone healing. The aim of this case report was to describe innovative regenerative endodontic therapy using L-PRF in the root canal and an extensive apical lesion in an immature tooth with dens invaginatus and asymptomatic apical periodontitis. A healthy 20-year-old woman was referred to the dental clinic of the Universidad de Los Andes, Santiago, Chile, for endodontic treatment in tooth # 22 with incomplete root development and an extensive apical lesion. The diagnosis was asymptomatic apical periodontitis associated with dens invaginatus type II. The patient was treated with an innovative approach using L-PRF in REPs associated with apical surgery. Follow-ups were performed at 6 months and 1 year later. They included periapical radiographs, cone-beam computed tomographic imaging, sensitivity, and vitality tests. The clinical evaluations performed at 6 months and 1 year revealed an absence of symptoms. The radiographic evaluations showed that the apical lesion was resolved. The cone-beam images indicated that the root length increased and the walls had thickened. The sensitivity tests were positive, and the laser Doppler flowmetry showed positive blood flow after 1 year. The success of the results in this case report indicate that L-PRF can be used as a complement in apical surgery and REPs and could provide an innovative alternative treatment strategy for complex clinical cases like these. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Khaleel, Maha; Puliyel, Mammen; Shah, Payal; Sunwoo, John; Kato, Roberta M; Chalacheva, Patjanaporn; Thuptimdang, Wanwara; Detterich, Jon; Wood, John C; Tsao, Jennie; Zeltzer, Lonnie; Sposto, Richard; Khoo, Michael C K; Coates, Thomas D
2017-11-01
The painful vaso-occlusive crises (VOC) that characterize sickle cell disease (SCD) progress over hours from the asymptomatic steady-state. SCD patients report that VOC can be triggered by stress, cold exposure, and, pain itself. We anticipated that pain could cause neural-mediated vasoconstriction, decreasing regional blood flow and promoting entrapment of sickle cells in the microvasculature. Therefore, we measured microvascular blood flow in the fingers of both hands using plethysmography and laser-Doppler flowmetry while applying a series of painful thermal stimuli on the right forearm in 23 SCD patients and 25 controls. Heat pain applied to one arm caused bilateral decrease in microvascular perfusion. The vasoconstriction response started before administration of the thermal pain stimulus in all subjects, suggesting that pain anticipation also causes significant vasoconstriction. The time delay between thermal pain application and global vasoconstriction ranged from 5 to 15.5 seconds and increased with age (P < .01). Although subjective measures, pain threshold and pain tolerance were not different between SCD subjects and controls, but the vaso-reactivity index characterizing the microvascular blood flow response to painful stimuli was significantly higher in SCD patients (P = .0028). This global vasoconstriction increases microvascular transit time, and may promote entrapment of sickle cells in the microvasculature, making vaso-occlusion more likely. The rapidity of the global vasoconstriction response indicates a neural origin that may play a part in the transition from steady-state to VOC, and may also contribute to the variability in VOC frequency observed in SCD patients. © 2017 Wiley Periodicals, Inc.
Stanhewicz, Anna E.; Proctor, David N.; Alexander, Lacy M.; Kenney, W. Larry
2015-01-01
During supine passive heating, increases in skin blood flow (SkBF) and cardiac output (Qc) are both blunted in older adults. The aim here was to determine the effect of acutely correcting the peripheral vasodilatory capacity of aged skin on the integrated cardiovascular responses to passive heating. A secondary aim was to examine the SkBF-Qc relation during hyperthermia in the presence (upright posture) and absence (dynamic exercise) of challenges to central venous pressure. We hypothesized that greater increases in SkBF would be accompanied by greater increases in Qc. Eleven healthy older adults (69 ± 3 yr) underwent supine passive heating (0.8°C rise in core temperature; water-perfused suit) after ingesting sapropterin (BH4, a nitric oxide synthase cofactor; 10 mg/kg) or placebo (randomized double-blind crossover design). Twelve young (24 ± 1 yr) subjects served as a comparison group. SkBF (laser-Doppler flowmetry) and Qc (open-circuit acetylene wash-in) were measured during supine heating, heating + upright posture, and heating + dynamic exercise. Throughout supine and upright heating, sapropterin fully restored the SkBF response of older adults to that of young adults but Qc remained blunted. During heat + upright posture, SkBF failed to decrease in untreated older subjects. There were no age- or treatment-related differences in SkBF-Qc during dynamic exercise. The principal finding of this study was that the blunted Qc response to passive heat stress is directly related to age as opposed to the blunted peripheral vasodilatory capacity of aged skin. Furthermore, peripheral impairments to SkBF in the aged may contribute to inapposite responses during challenges to central venous pressure during hyperthermia. PMID:26494450
Badtieva, V A; Kniazeva, T A; Apkhanova, T V
2010-01-01
The present review of the literature data highlights modern approaches to and major trends in diagnostics and conservative treatment of lymphedema of the lower extremities based on the generalized world experience. Patients with lymphedema of the lower extremities comprise a "difficult to manage" group because the disease is characterized by steady progression and marked refractoriness to various conservative therapeutic modalities creating problems for both the patient and the attending physician. Modern methods for the diagnosis of lymphedema are discussed with special reference to noninvasive and minimally invasive techniques (such as lymphoscintiography, computed tomography, MRT, laser Doppler flowmetry, etc.). During the last 20 years, combined conservative therapy has been considered as the method of choice for the management of different stages and forms of lymphedema of the lower extremities in foreign clinics. The basis of conservative therapy is constituted by manual lymph drainage (MLD), compression bandages using short-stretch materials, physical exercises, and skin care (using the method of M. Foldi). Also reviewed are the main physiobalneotherapeutic methods traditionally widely applied for the treatment of lymphedema of the lower extremities in this country. Original methods for the same purpose developed by the authors are described including modifications of cryotherapy, pulsed matrix laserotherapy, hydro- and balneotherapy. Mechanisms of their therapeutic action on the main pathogenetic factors responsible for the development of lymphedema (with special reference to lymph transport and formation) are discussed. The principles of combined application of physiotherapeutic methods for the rehabilitative treatment of patients presenting with lymphedema of the lower extremities are briefly substantiated. Special emphasis is laid on their influence on major components of the pathological process.
Told, Reinhard; Palkovits, Stefan; Haslacher, Helmuth; Frantal, Sophie; Schmidl, Doreen; Boltz, Agnes; Lasta, Michael; Kaya, Semira; Werkmeister, René M; Garhöfer, Gerhard; Schmetterer, Leopold
2013-01-01
A common polymorphism in the complement factor H gene (rs1061170, Y402H) is associated with a high risk of age-related macular degeneration (AMD). In the present study we hypothesized that healthy young subjects homozygous for the high-risk haplotype (CC) show abnormal choroidal blood flow (ChBF) regulation decades before potentially developing the disease. A total of 100 healthy young subjects were included in the present study, of which 4 subjects were excluded due to problems with genotyping or blood flow measurements. ChBF was measured continuously using laser Doppler flowmetry while the subjects performed isometric exercise (squatting) for 6 minutes. The increase in ChBF was less pronounced than the response in ocular perfusion pressure (OPP), indicating for some degree of choroidal blood flow regulation. Eighteen subjects were homozygous for C, 47 subjects were homozygous for T and 31 subjects were heterozygous (CT). The increase in OPP during isometric exercise was not different between groups. By contrast the increase in ChBF was more pronounced in subjects homozygous for the high risk C allele (p = 0.041). This was also evident from the pressure/flow relationship, where the increase in ChBF in homozygous C carriers started at lower OPPs as compared to the other groups. Our data indicate that the regulation of ChBF is abnormal in rs1061170 CC carriers. So far this polymorphism has been linked to age related macular degeneration (AMD) mainly via inflammatory pathways associated with the complement system dysfunction. Our results indicate that it could also be related to vascular factors that have been implicated in AMD pathogenesis.
Matsukawa, Kanji; Endo, Kana; Asahara, Ryota; Yoshikawa, Miho; Kusunoki, Shinya; Ishida, Tomoko
2017-11-01
Our laboratory reported that facial skin blood flow may serve as a sensitive tool to assess an emotional status. Cerebral neural correlates during emotional interventions should be sought in relation to the changes in facial skin blood flow. To test the hypothesis that prefrontal activity has positive relation to the changes in facial skin blood flow during emotionally charged stimulation, we examined the dynamic changes in prefrontal oxygenation (with near-infrared spectroscopy) and facial skin blood flows (with two-dimensional laser speckle and Doppler flowmetry) during emotionally charged audiovisual challenges for 2 min (by viewing comedy, landscape, and horror movie) in 14 subjects. Hand skin blood flow and systemic hemodynamics were simultaneously measured. The extents of pleasantness and consciousness for each emotional stimulus were estimated by subjective rating from -5 (the most unpleasant; the most unconscious) to +5 (the most pleasant; the most conscious). Positively charged emotional stimulation (comedy) simultaneously decreased ( P < 0.05) prefrontal oxygenation and facial skin blood flow, whereas negatively charged (horror) or neutral (landscape) emotional stimulation did not alter or slightly decreased them. Any of hand skin blood flow and systemic cardiovascular variables did not change significantly during positively charged emotional stimulation. The changes in prefrontal oxygenation had a highly positive correlation with the changes in facial skin blood flow without altering perfusion pressure, and they were inversely correlated with the subjective rating of pleasantness. The reduction in prefrontal oxygenation during positively charged emotional stimulation suggests a decrease in prefrontal neural activity, which may in turn elicit neurally mediated vasoconstriction of facial skin blood vessels. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Yamazaki, Fumio; Nakayama, Yoshiro; Sone, Ryoko
2006-04-01
To elucidate the influence of heat stress on cutaneous vascular response in the lower extremities during orthostatic stress, a head-up tilt (HUT) test at angles of 15 degrees, 30 degrees, 45 degrees, and 60 degrees for 4 min each was conducted under normothermic control conditions followed by whole-body heat stress produced by a hot water-perfused suit in healthy volunteers. Skin blood flows (SkBF) in the forearm, thigh, and calf were monitored using laser-Doppler flowmetry throughout the experiment. Furthermore, to elucidate the effects of increased core and local skin temperatures on the local vascular response in calf skin under increasing orthostatic stress, the thigh was occluded at 20, 30, 50, 70, and 80 mmHg with a cuff in both the normothermic condition and the whole-body or local heating condition. Significant decreases in forearm SkBF during HUT were observed at an angle of 60 degrees during normothermia and at 30 degrees or more during heating. SkBF in the thigh and calf was decreased significantly by HUT at 15 degrees and above during normothermia, and there was no significant reduction of SkBF in these sites during HUT at the lower angles (15 degrees -45 degrees ) during whole-body heating. Significant decreases of calf SkBF were observed at cuff pressures of 20 mmHg and above during normothermia and of 30 mmHg and above during whole-body and local heating, respectively. These results suggest that SkBF in the lower extremities shows a marked reduction compared with the upper extremities during low orthostatic stress in normothermia, and the enhanced skin vasoconstrictor response in the lower extremities is diminished by both whole-body and local heat stress.
Seebacher, Frank; Franklin, Craig E
2007-11-01
Changes in blood flow are a principal mechanism of thermoregulation in vertebrates. Changes in heart rate will alter blood flow, although multiple demands for limited cardiac output may compromise effective thermoregulation. We tested the hypothesis that regional differences in blood flow during heating and cooling can occur independently from changes in heart rate. We measured heart rate and blood pressure concurrently with blood flow in the crocodile, Crocodylus porosus. We measured changes in blood flow by laser Doppler flowmetry, and by injecting coloured microspheres. All measurements were made under different heat loads, with and without blocking cholinergic and beta-adrenergic receptors (autonomic blockade). Heart rates were significantly faster during heating than cooling in the control animals, but not when autonomic receptors were blocked. There were no significant differences in blood flow distribution between the control and autonomic blockade treatments. In both treatments, blood flow was directed to the dorsal skin and muscle and away from the tail and duodenum during heating. When the heat source was switched off, there was a redistribution of blood from the dorsal surface to the duodenum. Blood flow to the leg skin and muscle, and to the liver did not change significantly with thermal state. Blood pressure was significantly higher during the autonomic blockade than during the control. Thermal time constants of heating and cooling were unaffected by the blockade of autonomic receptors. We concluded that animals partially compensated for a lack of differential heart rates during heating and cooling by redistributing blood within the body, and by increasing blood pressure to increase flow. Hence, measures of heart rate alone are insufficient to assess physiological thermoregulation in reptiles.
Changes in skin microcirculation during radiation therapy for breast cancer.
Tesselaar, Erik; Flejmer, Anna M; Farnebo, Simon; Dasu, Alexandru
2017-08-01
The majority of breast cancer patients who receive radiation treatment are affected by acute radiation-induced skin changes. The assessment of these changes is usually done by subjective methods, which complicates the comparison between different treatments or patient groups. This study investigates the feasibility of new robust methods for monitoring skin microcirculation to objectively assess and quantify acute skin reactions during radiation treatment. Laser Doppler flowmetry, laser speckle contrast imaging, and polarized light spectroscopy imaging were used to measure radiation-induced changes in microvascular perfusion and red blood cell concentration (RBC) in the skin of 15 patients undergoing adjuvant radiation therapy for breast cancer. Measurements were made before treatment, once a week during treatment, and directly after the last fraction. In the treated breast, perfusion and RBC concentration were increased after 1-5 fractions (2.66-13.3 Gy) compared to baseline. The largest effects were seen in the areola and the medial area. No changes in perfusion and RBC concentration were seen in the untreated breast. In contrast, Radiation Therapy Oncology Group (RTOG) scores were increased only after 2 weeks of treatment, which demonstrates the potential of the proposed methods for early assessment of skin changes. Also, there was a moderate to good correlation between the perfusion (r = 0.52) and RBC concentration (r = 0.59) and the RTOG score given a week later. We conclude that radiation-induced microvascular changes in the skin can be objectively measured using novel camera-based techniques before visual changes in the skin are apparent. Objective measurement of microvascular changes in the skin may be valuable in the comparison of skin reactions between different radiation treatments and possibly in predicting acute skin effects at an earlier stage.
Caesar, Kirsten; Akgören, Nuran; Mathiesen, Claus; Lauritzen, Martin
1999-01-01
The hypothesis that potassium ions mediate activity-dependent increases of cerebral blood flow was examined in rat cerebellar cortex using ion-selective microelectrodes and laser-Doppler flowmetry. Increases of cerebellar blood flow (CeBF) and extracellular potassium concentration ([K+]o) were evoked by stimulation of parallel fibres and climbing fibres, and by microinjection of KCl into the cortex. For parallel fibre stimulation, there was a maximal increase in [K+]o to 6.3 ± 0.5 mm and in CeBF of 122 ± 11%. Climbing fibre stimulation gave a maximal increase in [K+]o to 4.4 ± 0.2 mm and in CeBF of 157 ± 20%. This indicates different maxima for [K+]o and CeBF, dependent on the afferent system activated. [K+]o and CeBF responses evoked by parallel or climbing fibre stimulation increased rapidly at the onset of stimulation, but exhibited different time courses during the remainder of the stimulation period and during return to baseline. Microinjections of KCl into the cortex increased [K+]o to levels comparable to those evoked by parallel fibre stimulation. The corresponding CeBF increases were the same as, or smaller than, for parallel fibre stimulation, and much smaller than for climbing fibre stimulation. This suggests that mediators other than [K+]o are important for activity-dependent cerebral blood flow increases. The present study showed that increased [K+]o is involved in CeBF regulation in the parallel fibre system, but is of limited importance for CeBF regulation in the climbing fibre system. The hypothesis that K+ is a major mediator of activity-dependent blood flow increases is probably not generally applicable to all brain regions and all types of neuronal stimulation. PMID:10517819
Effects of 14 days of head-down tilt bed rest on cutaneous vasoconstrictor responses in humans
NASA Technical Reports Server (NTRS)
Wilson, Thad E.; Shibasaki, Manabu; Cui, Jian; Levine, Benjamin D.; Crandall, Craig G.
2003-01-01
This study tested the hypothesis that head-down tilt bed rest (HDBR) reduces adrenergic and nonadrenergic cutaneous vasoconstrictor responsiveness. Additionally, an exercise countermeasure group was included to identify whether exercise during bed rest might counteract any vasoconstrictor deficits that arose during HDBR. Twenty-two subjects underwent 14 days of strict 6 degrees HDBR. Eight of these 22 subjects did not exercise during HDBR, while 14 of these subjects exercised on a supine cycle ergometer for 90 min a day at 75% of pre-bed rest heart rate maximum. To assess alpha-adrenergic vasoconstrictor responsiveness, intradermal microdialysis was used to locally administer norepinephrine (NE), while forearm skin blood flow (SkBF; laser-Doppler flowmetry) was monitored over microdialysis membranes. Nonlinear regression modeling was used to identify the effective drug concentration that caused 50% of the cutaneous vasoconstrictor response (EC(50)) and minimum values from the SkBF-NE dose-response curves. In addition, the effects of HDBR on nonadrenergic cutaneous vasoconstriction were assessed via the venoarteriolar response of the forearm and leg. HDBR did not alter EC(50) or the magnitude of cutaneous vasoconstriction to exogenous NE administration regardless of whether the subjects exercised during HDBR. Moreover, HDBR did not alter the forearm venoarteriolar response in either the control or exercise groups during HDBR. However, HDBR significantly reduced the magnitude of cutaneous vasoconstriction due to the venoarteriolar response in the leg, and this response was similarly reduced in the exercise group. These data suggest that HDBR does not alter cutaneous vasoconstrictor responses to exogenous NE administration, whereas cutaneous vasoconstriction of the leg due to the venoarteriolar response is reduced after HDBR. It remains unclear whether attenuated venoarteriolar responses in the lower limbs contribute to reduced orthostatic tolerance after bed rest and spaceflight.
Hemodynamic parameters change earlier than tissue oxygen tension in hemorrhage.
Pestel, Gunther J; Fukui, Kimiko; Kimberger, Oliver; Hager, Helmut; Kurz, Andrea; Hiltebrand, Luzius B
2010-05-15
Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after preparation, baseline measurements were taken. At first, 5% of total blood volume was withdrawn, followed by another 5% increment, and then in 10% increments until death. After withdrawal of 5% of estimated blood volume, dPP increased from 6.1% +/- 3.0% to 20.8% +/- 2.7% (P < 0.01). Mean arterial pressure (MAP), mean pulmonary artery pressure (PAP) and pulmonary artery occlusion pressure (PAOP) decreased with a blood loss of 10% (P < 0.01). Cardiac output (CO) changed after a blood loss of 20% (P < 0.05). Tissue oxygen tension in central organs, and blood flow in the jejunal muscularis decreased (P < 0.05) after a blood loss of 20%. Tissue oxygen tension in the skin, and jejunal mucosa blood flow decreased (P < 0.05) after a blood loss of 40% and 50%, respectively. In this hemorrhagic pig model systemic hemodynamic parameters were more sensitive to detect acute hypovolemia than tissue oxygen tension measurements or jejunal LDF measurements. Acute blood loss was detected first by dPP. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Lee, Shina; Ryu, Jung Hwa; Kim, Seung Jung; Ryu, Dong Ryeol; Kang, Duk Hee; Choi, Kyu Bok
2016-11-01
Chronic kidney disease (CKD) patients tend to have higher serum magnesium values than healthy population due to their positive balance of magnesium in kidney. Recent studies found that magnesium level is positively correlated with endothelial function. Therefore, this study was conducted to define the relationship between magnesium level and endothelial dysfunction in end stage renal disease (ESRD) patients on hemodialysis (HD). A total of 27 patients were included in this cross-sectional study. Iontophoresis with laser-Doppler flowmetry, flow mediated dilation (FMD), and carotid intima-media thickness were measured. Patients' average serum magnesium levels were measured over previous three months, including the examination month. Pearson's correlation coefficient analysis and multivariate regression model were used to define the association between magnesium and endothelial function. In the univariate analysis, higher magnesium levels were associated with better endothelium-dependent vasodilation (EDV) of the FMD in ESRD patients on HD (r=0.516, p=0.007). When the participants were divided into two groups according to the median magnesium level (3.47 mg/dL), there was a significant difference in EDV of FMD (less than 3.47 mg/dL, 2.8±1.7%; more than 3.47 mg/dL, 5.1±2.0%, p=0.004). In multivariate analysis, magnesium and albumin were identified as independent factors for FMD (β=1.794, p=0.030 for serum magnesium; β=3.642, p=0.012 for albumin). This study demonstrated that higher serum magnesium level may be associated with better endothelial function in ESRD patients on HD. In the future, a large, prospective study is needed to elucidate optimal range of serum magnesium levels in ESRD on HD patients.
Meertens, Robert; Casanova, Francesco; Knapp, Karen M; Thorn, Clare; Strain, William David
2018-05-04
A range of technologies using near infrared (NIR) light have shown promise at providing real time measurements of hemodynamic markers in bone tissue in vivo, an exciting prospect given existing difficulties in measuring hemodynamics in bone tissue. This systematic review aimed to evaluate the evidence for this potential use of NIR systems, establishing their potential as a research tool in this field. Major electronic databases including MEDLINE and EMBASE were searched using pre-planned search strategies with broad scope for any in vivo use of NIR technologies in human bone tissue. Following identification of studies by title and abstract screening, full text inclusion was determined by double blind assessment using predefined criteria. Full text studies for inclusion were data extracted using a predesigned proforma and quality assessed. Narrative synthesis was appropriate given the wide heterogeneity of included studies. Eighty-eight full text studies fulfilled the inclusion criteria, 57 addressing laser Doppler flowmetry (56 intra-operatively), 21 near infrared spectroscopy, and 10 photoplethysmography. The heterogeneity of the methodologies included differing hemodynamic markers, measurement protocols, anatomical locations, and research applications, making meaningful direct comparisons impossible. Further, studies were often limited by small sample sizes with potential selection biases, detection biases, and wide variability in results between participants. Despite promising potential in the use of NIR light to interrogate bone circulation, the application of NIR systems in bone requires rigorous assessment of the reproducibility of potential hemodynamic markers and further validation of these markers against alternative physiologically relevant reference standards. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:1-9, 2018. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Nonlinear dynamics of cardiovascular ageing
Shiogai, Y.; Stefanovska, A.; McClintock, P.V.E.
2010-01-01
The application of methods drawn from nonlinear and stochastic dynamics to the analysis of cardiovascular time series is reviewed, with particular reference to the identification of changes associated with ageing. The natural variability of the heart rate (HRV) is considered in detail, including the respiratory sinus arrhythmia (RSA) corresponding to modulation of the instantaneous cardiac frequency by the rhythm of respiration. HRV has been intensively studied using traditional spectral analyses, e.g. by Fourier transform or autoregressive methods, and, because of its complexity, has been used as a paradigm for testing several proposed new methods of complexity analysis. These methods are reviewed. The application of time–frequency methods to HRV is considered, including in particular the wavelet transform which can resolve the time-dependent spectral content of HRV. Attention is focused on the cardio-respiratory interaction by introduction of the respiratory frequency variability signal (RFV), which can be acquired simultaneously with HRV by use of a respiratory effort transducer. Current methods for the analysis of interacting oscillators are reviewed and applied to cardio-respiratory data, including those for the quantification of synchronization and direction of coupling. These reveal the effect of ageing on the cardio-respiratory interaction through changes in the mutual modulation of the instantaneous cardiac and respiratory frequencies. Analyses of blood flow signals recorded with laser Doppler flowmetry are reviewed and related to the current understanding of how endothelial-dependent oscillations evolve with age: the inner lining of the vessels (the endothelium) is shown to be of crucial importance to the emerging picture. It is concluded that analyses of the complex and nonlinear dynamics of the cardiovascular system can illuminate the mechanisms of blood circulation, and that the heart, the lungs and the vascular system function as a single entity in dynamical terms. Clear evidence is found for dynamical ageing. PMID:20396667
Real time monitoring of rat liver energy state during ischemia.
Barbiro, E; Zurovsky, Y; Mayevsky, A
1998-11-01
Hepatic failure is one of the major problems developed during the posttransplantation period. A possible cause of hepatic failure is the prolonged ischemia induced during the implantation procedure. Hepatic ischemia leads to a reduction in oxygen supply, ATP level decline, liver metabolism impairment, and finally organ failure. The purpose of this study was to estimate the functional state of the liver by monitoring liver blood flow and the mitochondrial NADH redox state simultaneously and continuously during in situ liver ischemia followed by reperfusion. Measurements were performed using the multiprobe developed in our laboratory consisting of fibers for the measurement of relative liver blood flow (laser Doppler flowmetry) and mitochondrial redox state (NADH fluorescence). The experimental procedure included the temporary interruption of blood flow to the liver using three types of ischemia, hepatic artery occlusion, portal vein occlusion, and simultaneous occlusion of hepatic artery and portal vein, followed by a reperfusion period. These preliminary experiments showed a significant decrease in liver blood flow, following the three types of liver ischemia, and a significant increase in NADH levels. The probe used in this study incorporates the advantage of monitoring NADH and liver blood flow simultaneously and continuously from the same area on the surface of the liver. Since each of these two parameters is not calibrated in absolute units, the simultaneous monitoring decreases possible artifacts. Also, it will allow us to determine of the coupling between tissue blood flow and oxidative phosphorylation. It is believed that the measurements of respiratory chain dysfunction might predict organ viability in clinical organ transplantation situations. Using this probe may also help to decrease the variability in liver blood flow monitoring since liver blood flow monitoring is supported simultaneously with the mitochondrial redox state, which supplies the information on liver metabolic and functional state. Copyright 1998 Academic Press.
Acute Cutaneous Microvascular Flow Responses to Whole-Body Tilting in Humans
NASA Technical Reports Server (NTRS)
Breit, Gregory A.; Watenpaugh, Donald E.; Ballard, Richard E.; Hargens, Alan R.
1993-01-01
The transition from upright to head-down tilt (HDT) posture in humans increases blood pressure superior to the heart and decreases pressure inferior to the heart. Consequently, above heart level, myogenic arteriolar tone probably increases with HDT, in opposition to the withdrawal of baroreceptor-mediated sympathetic tone. We hypothesized that due to antagonism between central and local controls, the response of the facial cutaneous micro- circulation to acute postural change will be weaker than that in the leg, where these two mechanisms reinforce each other. Cutaneous microvascular flow was measured by laser Doppler flowmetry simultaneously at the shin and the neck of 7 male and 3 female subjects. Subjects underwent a stepwise tilt protocol from standing control to 54 deg head-up tilt (HUT), 30 deg, 12 deg, 0 deg, -6 deg (HDT), -12 deg, -6 deg, 0 deg, 12 deg, 30 deg, 54 deg, and standing, for 30-sec periods with 10-sec transitions between postures. Flows at the shin and the neck increased significantly (P < 0.05) from standing baseline to 12 deg HUT (252 +/- 55 and 126 +/- 9% (bar-X +/- SE) of baseline, respectively). From 12 deg to -12 deg tilt, flows continued to increase at the shin (509 +/- 71% of baseline) but decreased at the neck to baseline levels (100 +/- 15% of baseline). Cutaneous microvascular flow recovered at both sites during the return to standing posture with significant hysteresis. Flow increases from standing to near-supine posture are attributed at both sites to baroreceptor-mediated vasodilation. The great dissimilarity in flow response magnitudes at the two measurement sites may be indicative of central/local regulatory antagonism above heart level and reinforcement below heart level.
Acute Cutaneous Microvascular Flow Responses to Whole-Body Tilting in Humans
NASA Technical Reports Server (NTRS)
Breit, Gregory A.; Watenpaugh, Donald E.; Ballard, Richard E.; Hargens, Alan R.
1993-01-01
The transition from upright to head-down tilt (HDT) posture in humans increases blood pressure superior to the heart and decreases pressure inferior to the heart. Consequently, above heart level, myogenic arteriolar tone probably increases with HDT, in opposition to the withdrawal of baroreceptor-mediated sympathetic tone. We hypothesized that due to antagonism between central and local controls, the response of the facial cutaneous microcirculation to acute postural change will be weaker than that in the leg, where these two mechanisms reinforce each other. Cutaneous microvascular flow was measured by laser Doppler flowmetry simultaneously at the shin and the neck of 7 male and 3 female subjects. Subjects underwent a stepwise tilt protocol from standing control to 54 deg head-up tilt (HUT), 30 deg, 12 deg, O deg, -6 deg (HDT), -12 deg, -6 deg, O deg, 12 deg, 30 deg, 54 deg, and standing, for 30-sec periods with 10-sec transitions between postures. Flows at the shin and the neck increased significantly (P less than 0.05) from standing baseline to 12 deg HUT (252 +/- 55 and 126 +/- 9% (bar X +/- SE) of baseline, respectively). From 12 deg to -12 deg tilt, flows continued to increase at the shin (509 +/- 71% of baseline) but decreased at the neck to baseline levels (100 +/- 15% of baseline). Cutaneous microvascular flow recovered at both sites during the return to standing posture with significant hysteresis. Flow increases from standing to near-supine posture are attributed at both sites to baroreceptor-mediated vasodilation. The great dissimilarity in flow response magnitudes at the two measurement sites may be indicative of central/local regulatory antagonism above heart level and reinforcement below heart level.
Messere, Alessandro; Roatta, Silvestro
2013-12-01
The potential interference of cutaneous circulation on muscle blood volume and oxygenation monitoring by near-infrared spectroscopy (NIRS) remains an important limitation of this technique. Spatially resolved spectroscopy (SRS) was reported to minimize the contribution of superficial tissue layers in cerebral monitoring but this characteristic has never been documented in muscle tissue monitoring. This study aims to compare SRS with the standard Beer-Lambert (BL) technique in detecting blood volume changes selectively induced in muscle and skin. In 16 healthy subjects, the biceps brachii was investigated during isometric elbow flexion at 70% of the maximum voluntary contractions lasting 10 sec, performed before and after exposure of the upper arm to warm air flow. From probes applied over the muscle belly the following variables were recorded: total hemoglobin index (THI, SRS-based), total hemoglobin concentration (tHb, BL-based), tissue oxygenation index (TOI, SRS-based), and skin blood flow (SBF), using laser Doppler flowmetry. Blood volume indices exhibited similar changes during muscle contraction but only tHb significantly increased during warming (+5.2 ± 0.7 μmol/L·cm, an effect comparable to the increase occurring in postcontraction hyperemia), accompanying a 10-fold increase in SBF. Contraction-induced changes in tHb and THI were not substantially affected by warming, although the tHb tracing was shifted upward by (5.2 ± 3.5 μmol/L·cm, P < 0.01). TOI was not affected by cutaneous warming. In conclusion, SRS appears to effectively reject interference by SBF in both muscle blood volume and oxygenation monitoring. Instead, BL-based parameters should be interpreted with caution, whenever changes in cutaneous perfusion cannot be excluded.
Sonenblum, Sharon E; Vonk, Teddie E; Janssen, Thomas W; Sprigle, Stephen H
2014-07-01
To investigate the effectiveness and interactions of 2 methods of pressure ulcer prevention, wheelchair cushions and pressure relief maneuvers, on interface pressure (IP) and blood flow of the buttocks. Within-subject repeated measures. Rehabilitation center. Wheelchair users with a spinal cord injury or disorder (N=17). Participants performed 3 forward leans and 2 sideward leans with different degrees of lean while seated on each of 3 different wheelchair cushions. IP measured with a custom sensor and blood flow measured with laser Doppler flowmetry were collected at the ischial tuberosity. Pressure relief maneuvers had a significant main effect on the ischial IP (P<.001); all maneuvers except for the small frontward lean resulted in a significant reduction in IP compared with upright sitting. Blood flow significantly varied across postures (P<.001) with flow during upright sitting and small forward leans being significantly lower than during the full and intermediate leans in both the forward and sideward directions. The results of the study highlight the importance of positioning wheelchair users in a manner that facilitates in-seat movement. Regardless of the cushion being used, the pressure relief maneuvers resulted in very large reductions in IPs and significant increases in buttock blood flow. Only the small frontward lean was shown to be ineffective in reducing pressure or increasing blood flow. Because these pressure relief maneuvers involved postural changes that can occur during functional activities, these pressure relief maneuvers can become a part of volitional pressure relief and functional weight shifts. Therefore, clinical instruction should cover both as a means to impart sitting behaviors that may lead to better tissue health. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Changes in human pulp blood flow during canine retraction.
Sabuncuoglu, Fidan Alakus; Ersahan, Seyda
2016-08-01
To evaluate the effects of maxillary canine retraction on pulpal blood flow (PBF) in humans as recorded by laser Doppler flowmetry (LDF). Maxillary canines of 24 participants were divided into two groups (n = 12 each). Teeth in the study group underwent maxillary canine retraction using mini-implants as anchorage for approximately 4 months, with 100 g of force applied via coil springs. Subjects in the control group received no orthodontic treatment. LDF measurements were recorded at baseline (T0); during retraction, at 24 hours (T1), 3 days (T2), 7 days (T3) and 1 month (T4); and at the end of retraction (T5) in the study group and at similar time-points in control subjects. Data were analyzed using the Friedman, Wilcoxon signed rank and Mann-Whitney U tests, with the significance level set at 0.05. No significant changes in PBF perfusion units (PU) were observed in the control group over the course of the study. However, PBF in the study group increased significantly from T0 (3.6 ± 0.2 PU) to T1 (3.7 ± 0.2 PU, p < 0.001) and decreased severely from T1 to T2 (3.3 ± 0.1, p < 0.001). PBF in the study group was still significantly lower at T3 (3.4 ± 0.1 PU, p < 0.001) in comparison to T0; however, at T4 and T5, PBF was found to have returned to pre-retraction levels. The fact that PBF values returned to initial levels within one month of the initiation of retraction despite short-term, hyperaemic, regressive changes demonstrates that the changes observed in PBF during canine retraction are reversible.
Ritt, Martin; Harazny, Joanna M; Ott, Christian; Raff, Ulrike; Bauernschubert, Philipp; Lehmann, Marina; Michelson, Georg; Schmieder, Roland E
2012-09-01
We hypothesized that the increase of retinal capillary blood flow (RCF) to flicker light exposure is impaired in subjects with arterial hypertension. In 146 nondiabetic untreated male subjects with (n=50) or without (n=96) arterial hypertension, RCF was measured before and after flicker light exposure noninvasively and in vivo using scanning laser Doppler flowmetry. In addition, in a subgroup of 28 subjects, the change of RCF to flicker light exposure was again assessed during parallel infusion of nitric oxide synthase inhibitor N-monomethyl-L-arginine (L-NMMA). The increase of RCF to flicker light exposure was lower in patients with untreated hypertension compared with normotensive subjects when expressed in absolute terms (7.69±54 versus 27.2±44 AU; P adjusted=0.013) or percent changes (2.95±14 versus 8.33±12%; P adjusted=0.023). Systolic (β=-0.216; P=0.023) but not diastolic blood pressure (β=-0.117; P=0.243) or mean arterial pressure (β=-0.178; P=0.073) was negatively related to the percent change of RCF to flicker light exposure, independently of other cardiovascular risk factors. In the subgroup of 28 subjects, the increase of RCF to flicker light exposure was similar at baseline and during parallel infusion of L-NMMA when expressed in absolute terms (20.0±51 versus 22.6±56 AU; P=0.731) or percent changes (7.12±16 versus 8.29±18%; P=0.607). The increase of RCF to flicker light exposure is impaired in arterial hypertension. In the subgroup of the total study cohort, nitric oxide was not a major determinant of the increase of RCF to flicker light exposure.
Rivas, Eric; McEntire, Serina J.; Herndon, David N.; Mlcak, Ronald P.; Suman, Oscar E.
2017-01-01
Objective Tested the hypothesis that propranolol, a drug given to burn patients to reduce hypermetabolism/cardiac stress, may inhibit heat dissipation by changing the sensitivity of skin blood flow (SkBF) to local heating under neutral and hot conditions. Methods In a randomized double-blind study, a placebo was given to 8 burned children while propranolol was given to 13 burned children with similar characteristics (mean ± SD: 11.9±3y, 147±20cm, 45±23kg, 56±12% TBSA). Non-burned children (n=13, 11.4±3y, 152±15cm, 52±13kg) served as healthy controls. A progressive local heating protocol characterized SkBF responses in burned and unburned skin and non-burned control skin under the two environmental conditions (23°C and 34°C) via laser-Doppler flowmetry. Results Resting SkBF was greater in burned and unburned skin compared to the non-burned control (main effect: skin, P<0.0001; 57±32 burned; 38±36 unburned vs 9±8 control %SkBFmax). No difference was found for maximal SkBF capacity to local heating between groups. Additionally, dose response curves for the sensitivity of SkBF to local heating were not different among burned or unburned skin, and non-burned control skin (EC50, P>0.05) under either condition. Conclusion Therapeutic propranolol does not negatively affect SkBF under neutral or hot environmental conditions and further compromise temperature regulation in burned children. PMID:28071840
Maley, Matthew J; House, James R; Tipton, Michael J; Eglin, Clare M
2017-05-01
Individuals of African descent (AFD) are more susceptible to non-freezing cold injury (NFCI) compared with Caucasian individuals (CAU). Vasodilatation to acetylcholine (ACh) is lower in AFD compared with CAU in the non-glabrous foot and finger skin sites; the reason for this is unknown. Prostanoids are responsible, in part, for the vasodilator response to ACh, however it is not known whether the contribution differs between ethnicities. 12 CAU and 12 AFD males received iontophoresis of ACh (1 w/v%) on non-glabrous foot and finger skin sites following placebo and then aspirin (600mg, single blinded). Aspirin was utilised to inhibit prostanoid production by inhibiting the cyclooxygenase (COX) enzyme. Laser Doppler flowmetry was utilised to measure changes in skin blood flow. Not all participants could receive iontophoresis charge due to high skin resistance; these participants were therefore excluded from the analyses. Foot: ACh elicited greater maximal vasodilatation in CAU than AFD following placebo (P=0.003) and COX inhibition (COXib) (P<0.001). COXib did not affect blood flow responses in AFD, but caused a reduction in the area under the curve for CAU (P=0.031). Finger: ACh elicited a greater maximal vasodilatation in CAU than AFD following placebo (P=0.013) and COXib (P=0.001). COXib tended to reduce the area under the curve in AFD (P=0.053), but did not affect CAU. CAU have a greater endothelial reactivity than AFD in both foot and finger skin sites irrespective of COXib. It is concluded that the lower ACh-induced vasodilatation in AFD is not due to a compromised COX pathway. Copyright © 2017 Elsevier Inc. All rights reserved.
Atochin, Dmitriy N.; Schepetkin, Igor A.; Khlebnikov, Andrei I.; Seledtsov, Victor I.; Swanson, Helen; Quinn, Mark T.; Huang, Paul L.
2017-01-01
The c-Jun N-terminal kinase (JNK) has been shown to be an important regulator of neuronal cell death. Previously, we synthesized the sodium salt of 11H-indeno[1,2-b]quinoxalin-11-one (IQ-1S) and demonstrated that it was a high-affinity inhibitor of the JNK family. In the present work, we found that IQ-1S could release nitric oxide (NO) during its enzymatic metabolism by liver microsomes. Moreover, serum nitrite/nitrate concentration in mice increased after intraperitoneal injection of IQ-1S. Because of these dual actions as JNK inhibitor and NO-donor, the therapeutic potential of IQ-1S was evaluated in an animal stroke model. We subjected wild-type C57BL6 mice to focal ischemia (30 minutes) with subsequent reperfusion (48 hours). Mice were treated with IQ-1S (25 mg/kg) suspended in 10% solutol or with vehicle alone 30 minutes before and 24 hours after middle cerebral artery MCA) occlusion (MCAO). Using laser-Doppler flowmetry, we monitored cerebral blood flow (CBF) above the MCA during 30 minutes of MCAO provoked by a filament and during the first 30 minutes of subsequent reperfusion. In mice treated with IQ-1S, ischemic and reperfusion values of CBF were not different from vehicle-treated mice. However, IQ-1S treated mice demonstrated markedly reduced neurological deficit and infarct volumes as compared with vehicle-treated mice after 48 hours of reperfusion. Our results indicate that the novel JNK inhibitor releases NO during its oxidoreductive bioconversion and improves stroke outcome in a mouse model of cerebral reperfusion. We conclude that IQ-1S is a promising dual functional agent for the treatment of cerebral ischemia and reperfusion injury. PMID:26923672
Kaner, Doğan; Soudan, Mouaz; Zhao, Han; Gaßmann, Georg; Schönhauser, Anna; Friedmann, Anton
2017-01-27
Early wound healing after periodontal surgery with or without enamel matrix derivative/biphasic calcium phosphate (EMD/BCP) was characterized in terms of soft tissue closure, changes of microcirculation, and expression of pro- and anti-inflammatory cytokines in gingival crevicular fluid/wound fluid (GCF/WF). Periodontal surgery was carried out in 30 patients (18 patients: application of EMD/BCP for regeneration of bony defects; 12 patients: surgical crown lengthening (SCL)). Healthy sites were observed as untreated controls. GCF/WF samples were collected during two post-surgical weeks. Flap microcirculation was measured using laser Doppler flowmetry (LDF). Soft tissue healing was evaluated after two weeks. GCF/WF levels of interleukin 1β (IL-1β), tumour necrosis factor (TNF-α), IL-6, and IL-10 were determined using a multiplex immunoassay. Surgery caused similar reductions of flap microcirculation followed by recovery within two weeks in both EMD/BCP and SCL groups. GCF/WF and pro-inflammatory cytokine levels were immediately increased after surgery, and returned only partially to baseline levels within the two-week observation period. Levels of IL-10 were temporarily reduced in all surgical sites. Flap dehiscence caused prolonged elevated levels of GCF/WF, IL-1β, and TNF-α. These findings show that periodontal surgery triggers an immediate inflammatory reaction corresponding to the early inflammatory phase of wound healing, and these inflammation measures are temporary in case of maintained closure of the flap. However, flap dehiscence causes prolonged inflammatory exudation from the periodontal wound. If the biological pre-conditions for periodontal wound healing are considered important for the clinical outcome, care should be taken to maintain primary closure of the flap.
NASA Astrophysics Data System (ADS)
Akgoren, Nuran; Fabricius, Martin; Lauritzen, Martin
1994-06-01
The endothelium-derived relaxing factor, probably nitric oxide (NO), is a potent vasodilator that regulates the vascular tone in several vascular beds, including the brain. We explored the possibility that NO might be of importance for the increase of cerebral blood flow (CBF) associated with activity of the well-defined neuronal circuits of the rat cerebellar cortex. Laser-Doppler flowmetry was used to measure increases of cerebellar blood flow evoked by trains of electrical stimulations of the dorsal surface. The evoked increases of CBF were frequency-dependent, being larger on than off the parallel fiber tracts, suggesting that conduction along parallel fibers and synaptic activation of target cells were important for the increase of CBF. This was verified experimentally since the evoked CBF increases were abolished by tetrodotoxin and reduced by 10 mM Mg2+ and selective antagonists for non-N-methyl-D-aspartate receptors. The cerebellar cortex contains high levels of NO synthase. This raised the possibility that NO was involved in the increase of CBF associated with neuronal activation. NO synthase inhibition by topical application of N^G-nitro-L-arginine attenuated the evoked CBF increase by about 50%. This effect was partially reversed by pretreatment with L-arginine, the natural substrate for the enzyme, while N^G-nitro-D-arginine, the inactive enantiomer, had no effect on the evoked CBF increases. Simultaneous blockade of non-N-methyl-D-aspartate receptors and NO synthase had no further suppressing effect on the blood flow increase than either substance alone, suggesting that the NO-dependent flow rise was dependent on postsynaptic mechanisms. These findings are consistent with the idea that local synthesis of NO is involved in the transduction mechanism between neuronal activity and increased CBF.
Reiner, Anton; Del Mar, Nobel; Zagvazdin, Yuri; Li, Chunyan; Fitzgerald, Malinda E C
2011-09-14
Choroidal vessels compensate for changes in systemic blood pressure (BP) so that choroidal blood flow (ChBF) remains stable over a BP range of approximately 40 mm Hg above and below basal. Because of the presumed importance of ChBF regulation for maintenance of retinal health, we investigated if ChBF compensation for BP fluctuation in pigeons fails with age. Transcleral laser Doppler flowmetry was used to measure ChBF during spontaneous BP fluctuation in anesthetized pigeons ranging in age from 0.5 to 17 years (pigeons can live approximately 20 years in captivity). ChBF in <8-year-old pigeons remained near 100% of basal ChBF at BPs ranging 40 mm Hg above and below basal BP (95 mm Hg). Baroregulation failed below approximately 50 mm Hg BP. In ≥8-year-old pigeons, ChBF compensation was absent at >90 mm Hg BP, with ChBF linearly following BP. Over the 60 to 90 mm Hg range, ChBF in ≥8-year-old pigeons was maintained at 60-70% of young basal ChBF. Below approximately 55 mm Hg, baroregulation again followed BP linearly. Age-related ChBF baroregulatory impairment occurs in pigeons, with ChBF linear with above-basal BP, and ChBF failing to adequately maintain ChBF during below-basal BP. Defective autonomic sympathetic and parasympathetic neurogenic control, or defective myogenic control, may cause these baroregulatory defects. In either case, overperfusion during high BP may cause oxidative injury to the outer retina, whereas underperfusion during low BP may result in deficient nutrient supply and waste removal, with both abnormalities contributing to age-related retinal pathology and vision loss.
NASA Technical Reports Server (NTRS)
Wilson, T. E.; Cui, J.; Crandall, C. G.
2001-01-01
1. Prior findings suggest that baroreflexes are capable of modulating skin blood flow, but the effects of baroreceptor loading/unloading on sweating are less clear. Therefore, this project tested the hypothesis that pharmacologically induced alterations in arterial blood pressure in heated humans would lead to baroreflex-mediated changes in both skin sympathetic nerve activity (SSNA) and sweat rate. 2. In seven subjects mean arterial blood pressure was lowered (approximately 8 mmHg) and then raised (approximately 13 mmHg) by bolus injections of sodium nitroprusside and phenylephrine, respectively. Moreover, in a separate protocol, arterial blood pressure was reduced via steady-state administration of sodium nitroprusside. In both normothermia and heat-stress conditions the following responses were monitored: sublingual and mean skin temperatures, heart rate, beat-by-beat blood pressure, skin blood flow (laser-Doppler flowmetry), local sweat rate and SSNA (microneurography from peroneal nerve). 3. Whole-body heating increased skin and sublingual temperatures, heart rate, cutaneous blood flow, sweat rate and SSNA, but did not change arterial blood pressure. Heart rate was significantly elevated (from 74 +/- 3 to 92 +/- 4 beats x min(-1); P < 0.001) during bolus sodium nitroprusside-induced reductions in blood pressure, and significantly reduced (from 92 +/- 4 to 68 +/- 4 beats x min(-1); P < 0.001) during bolus phenylephrine-induced elevations in blood pressure, thereby demonstrating normal baroreflex function in these subjects. 4. Neither SSNA nor sweat rate was altered by rapid (bolus infusion) or sustained (steady-state infusion) changes in blood pressure regardless of the thermal condition. 5. These data suggest that SSNA and sweat rate are not modulated by arterial baroreflexes in normothermic or moderately heated individuals.
Wu, Xing-Huo; Yang, Shu-Hua; Duan, De-Yu; Cheng, Heng-Hui; Bao, Yu-Ting; Zhang, Yukun
2007-09-01
Recent studies confirmed that the new cell survival signal pathway of Insulin-PI3K-Akt exerted cyto-protective actions involving anti-apoptosis. This study was undertaken to investigate the potential neuroprotective effects of insulin in the pathogenesis of spinal cord injury (SCI) and evaluate its therapeutic effects in adult rats. SCI was produced by extradural compression using modified Allen's stall with damage energy of 40 g-cm force. One group of rats was subjected to SCI in combination with the administration of recombinant human insulin dissolved in 50% glucose solution at the dose of 1 IU/kg day, for 7 days. At the same time, another group of rats was subjected to SCI in combination with the administration of an equal volume of sterile saline solution. Functional recovery was evaluated using open-field walking, inclined plane tests, and motor evoked potentials (MEPs) during the first 14 days post-trauma. Levels of protein for B-cell lymphoma/leukemia-2 gene (Bcl-2), Caspase-3, inducible nitric oxide synthase (iNOS), and cyclooxygenase-2 (COX-2) were quantified in the injured spinal cord by Western blot analysis. Neuronal apoptosis was detected by TUNEL, and spinal cord blood flow (SCBF) was measured by laser-Doppler flowmetry (LDF). Ultimately, the data established the effectiveness of insulin treatment in improving neurologic recovery, increasing the expression of anti-apoptotic bcl-2 proteins, inhibiting caspase-3 expression decreasing neuronal apoptosis, reducing the expression of proinflammatory cytokines iNOS and COX-2, and ameliorating microcirculation of injured spinal cord after moderate contusive SCI in rats. In sum, this study reported the beneficial effects of insulin in the treatment of SCI, with the suggestion that insulin should be considered as a potential therapeutic agent.
Increase in slow-wave vasomotion by hypoxia and ischemia in lowlanders and highlanders.
Salvi, Paolo; Faini, Andrea; Castiglioni, Paolo; Brunacci, Fausto; Montaguti, Luca; Severi, Francesca; Gautier, Sylvie; Pretolani, Enzo; Benetos, Athanase; Parati, Gianfranco
2018-06-21
The physiological relevance of slow-wave vasomotion is still unclear, even it has been hypothesized it could be a compensatory mechanism enhancing tissue oxygenation in conditions of reduced oxygen supply. Aim of our study was to explore the effects of hypoxia and ischemia on slow-wave vasomotion in microcirculation. Peripheral oxygen saturation and forearm microcirculation flow (laser-Doppler flowmetry) were recorded at baseline and during post-occlusive reactive hyperemia in the Himalaya region from 8 European lowlanders (6 males; aged 29-39yrs) at 1350, 3400 and 5050m, and from 10 Nepalese male highlanders (aged 21-39yrs) at 3400 and 5050m of altitude. The same measurements were also performed at sea level in 16 healthy volunteers (aged 23-61yrs) during a short-term exposure to normobaric hypoxia. In lowlanders, exposure to progressively higher altitude under baseline flow conditions progressively increased 0.06-0.15Hz vasomotion amplitude [power spectral density % expressed as geometric means (geometric standard deviation) =14.0(3.6) at 1350m; 87.0(2.3) at 3400m and 249.8(3.6) at 5050m, p=0.006 and p<0.001 vs 1350m, respectively]. In highlanders, low frequency vasomotion amplitude was similarly enhanced at different altitudes [power spectral density % =183.4(4.1) at 3400m vs 236.0(3.0) at 5050m, p=0.139]. In both groups at altitude it was further increased after ischemic stimulus (p<0.001). At baseline, acute short lasting normobaric hypoxia did not induce low frequency vasomotion, which was conversely induced by ischemia even under normal oxygenation and barometric pressure. This study offers the demonstration of a significant increase in slow-wave vasomotion under prolonged hypobaric-hypoxia exposure at high altitude, with a further enhancement after ischemia induction.
Is gut the "motor" for producing hepatocellular dysfunction after trauma and hemorrhagic shock?
Wang, P; Ba, Z F; Cioffi, W G; Bland, K I; Chaudry, I H
1998-02-01
Although studies suggest that the gut may be the "motor" responsible for producing sepsis and multiple organ failure after injury, it is not known whether enterectomy prior to the onset of hemorrhage alters proinflammatory cytokines TNF and IL-6 and, if so, whether hepatocellular dysfunction and damage are prevented or attenuated under such conditions. Under methoxyflurane anesthesia, an enterectomy in the rat was performed by excision of the duodenum, jejunum, and ileum. The rats were then bled to and maintained at a mean arterial pressure of 40 mm Hg until 40% of the maximal shed volume was returned in the form of Ringer's lactate. The animals were then resuscitated with four times the volume of shed blood with Ringer's lactate over 1 h. At 1.5 h after the completion of resuscitation, hepatocellular function [i.e., the maximal velocity (Vmax) and transport efficiency (Km) of indocyanine green (ICG) clearance] was assessed by an in vivo ICG clearance technique. Blood samples were taken for the measurement of TNF, IL-6, and liver enzymes (i.e., SGPT and SGOT). Cardiac output and microvascular blood flow were determined by ICG dilution and laser Doppler flowmetry, respectively. The increase in circulating levels of TNF but not IL-6 was prevented by enterectomy prior to hemorrhage. The reduced Vmax and K(m) and elevated SGPT and SGOT following hemorrhage and resuscitation, however, were not significantly affected by prior enterectomy. Moreover, enterectomy before hemorrhage further reduced hepatic perfusion. Since enterectomy prior to the onset of hemorrhage does not prevent or attenuate the reduced ICG clearance and elevated liver enzymes despite downregulation of TNF production, it appears that the small intestine does not play a significant role in producing hepatocellular dysfunction and injury following trauma and hemorrhagic shock.
Zegarra-Parodi, Rafael; Pazdernik, Vanessa K; Roustit, Matthieu; Park, Peter Yong Soo; Degenhardt, Brian F
2016-02-01
Peripheral skin blood flow (SBF) changes during and after spinal mobilization (SM), evaluated with laser Doppler flowmetry, may document physiological responses associated with SM. To document variations in SBF during and after application of an SM and evaluate influence of pressure on SBF by applying the same standardized SM with 3 different nonnoxious pressures. Cross-over design with 4 interventions on 4 different days: control (no touch) and 3 SMs applied rhythmically at 5%, 40%, or 80% of pain pressure threshold (sham SM, low-pressure SM, or high-pressure SM, respectively). Thirty-two individuals participated. The inspiratory gasp (IG) test was our positive control of vasoconstriction through excitation of the skin sympathetic nervous activity (SSNA). Each session comprised 5 phases: (1) baseline at the end of a 20-min acclimatization, (2) IG test, (3) post-IG phase, (4) SM phase or no manual contact for control, and (5) post-SM phase. A Biopac MP36 system collected SBF data, and a Novel Pliance-X system recorded pressure data. Equal and significant bilateral vasodilation occurred during application of unilateral sham SM, low-pressure SM, and high-pressure SM. Post-SM significant vasodilation persisted after high-pressure SM. The current study is the first to describe bilateral peripheral SBF changes occurring during and 5 min after application of standardized SMs. Our post-SM vasodilation suggests involvement of mechanisms other than the putative SSNA-excitatory mechanism proposed with skin conductance measurements. Persistence of post-SM vasodilation following only high-pressure SM suggests possible pressure-dependent mechanisms. However, further research is warranted to clarify our findings. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rothenberger, Jens; Petersen, Wiebke; Schaller, Hans-Eberhard; Held, Manuel
2016-11-01
A universal protocol determining the number of leeches and their application time does not exist. The aim of this study, therefore, is to quantify perfusion dynamics in venous congested tissues after leech application to get more detailed information about changes due to leech-induced skin microcirculation and to evaluate the usability of the Oxygen to See (O2C) device in terms of determining the appropriate number of leeches and the duration of therapy. Twelve patients with the need for leech therapy participated in the study. Perfusion dynamics of the congested tissue was assessed using the O2C device, which determines blood flow (BF), the relative amount of hemoglobin (rHB), and the oxygen saturation (SO2). Measurements were carried out before leech application and on various intervals like 10 minutes, one hour, and three hours after leech application. The leech application effectuated after 10 minutes a nonsignificant perfusion improvement, which further increased after one hour with a significant reduction of the relative amount of hemoglobin and a significant increase of blood flow and oxygen saturation (BF= +56.7%; rHB= -25.5%; SO2= +53.7%). After three hours, the values returned to the levels before leech administration. In two cases, in which further administration of leeches within the measurement period was necessary, no substantial perfusion changes were obtained. The results of this study forms a more precise pattern of microcirculatory changes of leech therapy in congested tissues. According to our measurements a venous drainage improvement can be expected in congested tissue one hour after leech administration. The O2C seems to be a useful method to determine the appropriate number and duration of leech therapy. © 2016 by the Wound Healing Society.
Kulchitskaya, D B; Gerasimenko, M Yu; Aphanova, T V; Konchugova, T V
The principal objective of the present work was to evaluate the influence of impulse magnetic therapy on the state of the microcirculatory system in the patients presenting with lymphedema of the lower extremities. The study included 59 patients with stage of 1 and 2 lymphedema who were divided into two groups. Those comprising the first group had impulse magnetic therapy applied to their lower extremities while the patients making up the second group served as controls. All the patients were examined with the use of the laser Doppler flowmetry (LDF) that revealed the initially present pathological changes in the microcirculatory system of their lower extremities. The study has demonstrated that the application of impulse magnetic therapy produced a positive effect on all the constituent components of the microcirculatory blood stream of the patients suffering from lymphedema of the lower extremities. Specifically, the initially increased arteriolar tonus was decreased, the blood flow in the capillary vessels was improved, and congestive phenomena in the venular segments of the microcirculation blood stream were markedly reduced. The results of the LDF examination in the control group gave no evidence of significant changes in the patients' microcirculatory system. The results of the LDF examination of the patients of the control group suggested the absence of any appreciable changes in the microcirculatory system. The present study has demonstrated the advisability of the application of impulse magnetic therapy for the treatment of the patients presenting with lymphedema of the lower extremities as a minimally invasive technique for the evaluation of the condition of the microcirculatory system and the objective assessment of the effectiveness of the outcomes of physiotherapy in the patients with vascular pathology.
Sanchez Armengol, Angeles; Moreno-Luna, Rafael; Caballero-Eraso, Candela; Macher, Hada C.; Villar, Jose; Merino, Ana M; Castell, Javier; Capote, Francisco; Stiefel, Pablo
2015-01-01
Study objectives This study tries to assess the endothelial function in vivo using flow-mediated dilatation (FMD) and several biomarkers of endothelium formation/restoration and damage in patients with obstructive sleep apnoea (OSA) syndrome at baseline and after three months with CPAP therapy. Design Observational study, before and after CPAP therapy. Setting and Patients We studied 30 patients with apnoea/hypopnoea index (AHI) >15/h that were compared with themselves after three months of CPAP therapy. FMD was assessed non-invasively in vivo using the Laser-Doppler flowmetry. Circulating cell-free DNA (cf-DNA) and microparticles (MPs) were measured as markers of endothelial damage and the vascular endothelial growth factor (VEGF) was determined as a marker of endothelial restoration process. Measurements and results After three month with CPAP, FMD significantly increased (1072.26 ± 483.21 vs. 1604.38 ± 915.69 PU, p< 0.005) cf-DNA and MPs significantly decreased (187.93 ± 115.81 vs. 121.28 ± 78.98 pg/ml, p<0.01, and 69.60 ± 62.60 vs. 39.82 ± 22.14 U/μL, p<0.05, respectively) and VEGF levels increased (585.02 ± 246.06 vs. 641.11 ± 212.69 pg/ml, p<0.05). These changes were higher in patients with more severe disease. There was a relationship between markers of damage (r = -0.53, p<0.005) but not between markers of damage and restoration, thus suggesting that both types of markers should be measured together. Conclusions CPAP therapy improves FMD. This improvement may be related to an increase of endothelial restoration process and a decrease of endothelial damage. PMID:25815511
Stupin, Ana; Rasic, Lidija; Matic, Anita; Stupin, Marko; Kralik, Zlata; Kralik, Gordana; Grcevic, Manuela; Drenjancevic, Ines
2018-04-10
Whilst the beneficial effect of omega-3 polyunsaturated fatty acids (PUFAs) supplementation on cardiovascular (CV) system is well supported in CV patients, the effect of consumption of omega-3 PUFAs enriched functional food in healthy individuals is still not fully elucidated. This study aimed to determine the effect of consumption of omega-3 PUFAs enriched hen eggs on microvascular reactivity (primary outcome), blood pressure (BP) and serum lipid profile in young healthy individuals. Control group (N=16) ate three ordinary hen eggs (277 mg omega-3 PUFAs/day), and OMEGA-3 group (N=20) ate three omega-3 PUFAs enriched eggs containing 259 mg of omega-3 PUFAs/egg daily (ALA 167 mg/egg, EPA 7 mg/egg, DHA 84 mg/egg) for 3 weeks (777 mg omega-3 PUFAs/day). Post-occlusive reactive hyperemia (PORH) in skin microcirculation assessed by laser Doppler flowmetry, serum lipid profile, fasting blood glucose, high-sensitivity C-reactive protein (hsCRP) and arterial BP were measured in all subjects before and after the protocol. PORH was significantly enhanced, and triglycerides, hsCRP and BP were significantly decreased in OMEGA-3 group compared to baseline measurement, while there was no significant difference in Control group after the protocol compared to baseline. This is the first study to demonstrate that consumption of a mixture of omega-3 PUFAs (ALA+EPA+DHA), provided via enriched hen eggs, elicits changes in microvascular reactivity, BP and triglycerides level in healthy subjects that are associated with CV benefits, thus suggesting that daily consumption of omega-3 PUFAs enriched eggs in healthy individuals may potentially contribute to CV risk factors attenuation and disease prevention.
Nitric oxide is not permissive for cutaneous active vasodilatation in humans.
Wilkins, Brad W; Holowatz, Lacy A; Wong, Brett J; Minson, Christopher T
2003-05-01
The precise role of nitric oxide (NO) in cutaneous active vasodilatation in humans is unknown. We tested the hypothesis that NO is necessary to permit the action of an unknown vasodilator. Specifically, we investigated whether a low-dose infusion of exogenous NO, in the form of sodium nitroprusside (SNP), would fully restore vasodilatation in an area of skin in which endogenous NO was inhibited during hyperthermia. This finding would suggest a 'permissive' role for NO in active vasodilatation. Eight subjects were instrumented with three microdialysis fibres in forearm skin. Sites were randomly assigned to (1) Site A: control site; (2) Site B: NO synthase (NOS) inhibition during established hyperthermia; or (3) Site C: NOS inhibition throughout the protocol. Red blood cell flux was measured using laser-Doppler flowmetry (LDF) and cutaneous vascular conductance (CVC; LDF/mean arterial pressure) was normalized to maximal vasodilatation at each site. In Site B, NG-nitro-L-arginine methyl ester (L-NAME) infusion during hyperthermia reduced CVC by approximately 32 % (65 +/- 4 % CVCmax vs. 45 +/- 4 % CVCmax; P < 0.05). Vasodilatation was not restored to pre-NOS inhibition values in this site following low-dose SNP infusion (55 +/- 4 % CVCmax vs. 65 +/- 4 % CVCmax; P < 0.05). CVC remained significantly lower than the control site with low-dose SNP infusion in Site C (P < 0.05). The rise in CVC with low-dose SNP (deltaCVC) was significantly greater in Site B and Site C during hyperthermia compared to normothermia (P < 0.05). No difference in deltaCVC was observed between hyperthermia and normothermia in the control site (Site A). Thus, NO does not act permissively in cutaneous active vasodilatation in humans but may directly mediate vasodilatation and enhance the effect of an unknown active vasodilator.
Polska, Elzbieta; Doelemeyer, Arno; Luksch, Alexandra; Ehrlich, Paulina; Kaehler, Nils; Percicot, Christine L; Lambrou, George N; Schmetterer, Leopold
2002-03-01
There is increasing evidence that reduced ocular blood flow plays a role in the pathogenesis of glaucoma. In patients with normal-tension glaucoma, ocular blood flow abnormalities may be associated with dysfunction of the endothelin 1 (ET-1) regulation system. To test the hypothesis that unoprostone, a topical docosanoid, may affect ET-1--induced vasoconstriction in the human choroid. In a placebo-controlled, randomized, double-masked, 2-way crossover design, ET-1 (2.5 ng/kg per minute for 150 minutes) was administered intravenously to 24 healthy individuals. Thirty minutes after the start of ET-1 infusion, 1 drop of unoprostone or placebo was instilled into the right eye. After another 30 minutes, 2 drops of unoprostone or placebo was topically administered. This procedure was continued and the dose was increased further until 4 drops of unoprostone or placebo was reached. Subfoveal and pulsatile choroidal blood flow were assessed using laser Doppler flowmetry and laser interferometric measurement of fundus pulsation amplitude, respectively. Administration of exogenous ET-1 decreased choroidal blood flow (mean +/- SEM, 17% +/- 2%; P<.001) and fundus pulsation amplitude (mean +/- SEM, 19% +/- 2%; P<.001). This effect was significantly blunted when topical unoprostone was coadministered (mean +/- SEM decrease in choroidal blood flow, 7% +/- 2%; P =.04 vs. placebo; mean +/- SEM decrease in fundus pulsation amplitude, 12% +/- 2%; P<.001 vs. placebo). There is a functional antagonism between ET-1 and topical unoprostone in the choroidal vasculature. Our findings of a functional antagonism between ET-1 and topical unoprostone in the choroidal vasculature may be important in vascular eye diseases associated with increased ET-1.
Polska, Elzbieta; Ehrlich, Paulina; Luksch, Alexandra; Fuchsjäger-Mayrl, Gabriele; Schmetterer, Leopold
2003-07-01
There is evidence from a variety of animal studies that the adenosine system plays a role in the control of intraocular pressure (IOP) and ocular blood flow. However, human data on the effect of adenosine on IOP and choroidal and optic nerve blood flow are not available. The effect of stepwise increases in doses of adenosine (10, 20, and 40 micro g/kg per minute, 30 minutes per infusion step) on optic nerve head blood flow, choroidal blood flow, and IOP was determined in a placebo-controlled double-masked clinical trial in 12 healthy male volunteers. Blood flow in the optic nerve head and choroid was measured with laser Doppler flowmetry. In addition, fundus pulsation amplitude in the macula (FPAM) and the optic nerve head (FPAO) were assessed with laser interferometry. Adenosine induced a small but significant decrease in IOP (at 40 microg/kg per minute: 12% +/- 13%), which was significant versus placebo (P = 0.046). In addition, adenosine induced a significant increase in choroidal blood flow (P < 0.001) and optic nerve head blood flow (P = 0.037), and FPAM (P = 0.0014) and tended to increase FPAO (P = 0.057). At the highest administered dose, the effect on choroidal hemodynamic parameters between 14% and 17%, whereas the effect on optic nerve hemodynamic parameters was between 3% and 11%. These data are consistent with adenosine inducing choroidal and optic nerve head vasodilatation and reducing IOP in healthy humans. Considering the neuroprotective properties of adenosine described in previous animal experiments the adenosine system is an attractive target system for therapeutic approaches in glaucoma.
Role of NO in the control of choroidal blood flow during a decrease in ocular perfusion pressure.
Simader, Christian; Lung, Solveig; Weigert, Günther; Kolodjaschna, Julia; Fuchsjäger-Mayrl, Gabriele; Schmetterer, Leopold; Polska, Elzbieta
2009-01-01
The study was conducted to investigate whether the L-arginine/nitric oxide system plays a role in choroidal blood flow (ChBF) regulation during a decrease in ocular perfusion pressure (OPP). Experiments were performed on 3 days in a randomized double-masked, placebo-controlled, three-way crossover design. On different study days, subjects received intravenous infusions of N(G)-monomethyl-L-arginine (L-NMMA), phenylephrine, or placebo. Intraocular pressure was raised in stepwise increments using the suction cup Choroidal blood flow (ChBF, laser Doppler flowmetry), mean arterial blood pressure (MAP), and IOP were assessed. Ocular perfusion pressure was calculated as OPP = 23(MAP - IOP). For correlation analysis all OPP/ChBF data pairs from all subjects were pooled independent of time point of measurement. Then, the pooled data were sorted according to OPP, and correlation analyses were performed. L-NMMA and phenylephrine increased resting OPP by +17% +/- 18% and +14% +/- 21%, respectively (P < 0.05). L-NMMA reduced resting ChBF by -21% +/- 17% (P < 0.05). The relative decrease in OPP during suction cup application was comparable with all drugs administered. The decrease in OPP was paralleled by a significant decrease in ChBF (maximum between -39% and -47%), which was less pronounced, however, than the decrease in OPP (maximum between -69% and -74%). Neither placebo nor L-NMMA, nor phenylephrine, influenced the OPP/ChBF relationship. The data confirm previously published observations that the choroid shows some regulatory capacity during reduced OPP. The L-arginine/nitric oxide-system plays a role in the maintenance of basal vascular tone but seems not to be involved in the choroidal vasodilator response when IOP is increased.
Nonlinear dynamics of cardiovascular ageing
NASA Astrophysics Data System (ADS)
Shiogai, Y.; Stefanovska, A.; McClintock, P. V. E.
2010-03-01
The application of methods drawn from nonlinear and stochastic dynamics to the analysis of cardiovascular time series is reviewed, with particular reference to the identification of changes associated with ageing. The natural variability of the heart rate (HRV) is considered in detail, including the respiratory sinus arrhythmia (RSA) corresponding to modulation of the instantaneous cardiac frequency by the rhythm of respiration. HRV has been intensively studied using traditional spectral analyses, e.g. by Fourier transform or autoregressive methods, and, because of its complexity, has been used as a paradigm for testing several proposed new methods of complexity analysis. These methods are reviewed. The application of time-frequency methods to HRV is considered, including in particular the wavelet transform which can resolve the time-dependent spectral content of HRV. Attention is focused on the cardio-respiratory interaction by introduction of the respiratory frequency variability signal (RFV), which can be acquired simultaneously with HRV by use of a respiratory effort transducer. Current methods for the analysis of interacting oscillators are reviewed and applied to cardio-respiratory data, including those for the quantification of synchronization and direction of coupling. These reveal the effect of ageing on the cardio-respiratory interaction through changes in the mutual modulation of the instantaneous cardiac and respiratory frequencies. Analyses of blood flow signals recorded with laser Doppler flowmetry are reviewed and related to the current understanding of how endothelial-dependent oscillations evolve with age: the inner lining of the vessels (the endothelium) is shown to be of crucial importance to the emerging picture. It is concluded that analyses of the complex and nonlinear dynamics of the cardiovascular system can illuminate the mechanisms of blood circulation, and that the heart, the lungs and the vascular system function as a single entity in dynamical terms. Clear evidence is found for dynamical ageing.
Lee, Shina; Ryu, Jung-Hwa; Kim, Seung-Jung; Ryu, Dong-Ryeol; Kang, Duk-Hee
2016-01-01
Purpose Chronic kidney disease (CKD) patients tend to have higher serum magnesium values than healthy population due to their positive balance of magnesium in kidney. Recent studies found that magnesium level is positively correlated with endothelial function. Therefore, this study was conducted to define the relationship between magnesium level and endothelial dysfunction in end stage renal disease (ESRD) patients on hemodialysis (HD). Materials and Methods A total of 27 patients were included in this cross-sectional study. Iontophoresis with laser-Doppler flowmetry, flow mediated dilation (FMD), and carotid intima-media thickness were measured. Patients' average serum magnesium levels were measured over previous three months, including the examination month. Pearson's correlation coefficient analysis and multivariate regression model were used to define the association between magnesium and endothelial function. Results In the univariate analysis, higher magnesium levels were associated with better endothelium-dependent vasodilation (EDV) of the FMD in ESRD patients on HD (r=0.516, p=0.007). When the participants were divided into two groups according to the median magnesium level (3.47 mg/dL), there was a significant difference in EDV of FMD (less than 3.47 mg/dL, 2.8±1.7%; more than 3.47 mg/dL, 5.1±2.0%, p=0.004). In multivariate analysis, magnesium and albumin were identified as independent factors for FMD (β=1.794, p=0.030 for serum magnesium; β=3.642, p=0.012 for albumin). Conclusion This study demonstrated that higher serum magnesium level may be associated with better endothelial function in ESRD patients on HD. In the future, a large, prospective study is needed to elucidate optimal range of serum magnesium levels in ESRD on HD patients. PMID:27593873
Rivas, Eric; McEntire, Serina J; Herndon, David N; Mlcak, Ronald P; Suman, Oscar E
2017-05-01
We tested the hypothesis that propranolol, a drug given to burn patients to reduce hypermetabolism/cardiac stress, may inhibit heat dissipation by changing the sensitivity of skin blood flow (SkBF) to local heating under neutral and hot conditions. In a randomized double-blind study, a placebo was given to eight burned children, while propranolol was given to 13 burned children with similar characteristics (mean±SD: 11.9±3 years, 147±20 cm, 45±23 kg, 56±12% Total body surface area burned). Nonburned children (n=13, 11.4±3 years, 152±15 cm, 52±13 kg) served as healthy controls. A progressive local heating protocol characterized SkBF responses in burned and unburned skin and nonburned control skin under the two environmental conditions (23 and 34°C) via laser Doppler flowmetry. Resting SkBF was greater in burned and unburned skin compared to the nonburned control (main effect: skin, P<.0001; 57±32 burned; 38±36 unburned vs 9±8 control %SkBF max ). No difference was found for maximal SkBF capacity to local heating between groups. Additionally, dose-response curves for the sensitivity of SkBF to local heating were not different among burned or unburned skin, and nonburned control skin (EC 50 , P>.05) under either condition. Therapeutic propranolol does not negatively affect SkBF under neutral or hot environmental conditions and further compromise temperature regulation in burned children. © 2017 John Wiley & Sons Ltd.
Messere, Alessandro; Roatta, Silvestro
2013-01-01
Abstract The potential interference of cutaneous circulation on muscle blood volume and oxygenation monitoring by near‐infrared spectroscopy (NIRS) remains an important limitation of this technique. Spatially resolved spectroscopy (SRS) was reported to minimize the contribution of superficial tissue layers in cerebral monitoring but this characteristic has never been documented in muscle tissue monitoring. This study aims to compare SRS with the standard Beer–Lambert (BL) technique in detecting blood volume changes selectively induced in muscle and skin. In 16 healthy subjects, the biceps brachii was investigated during isometric elbow flexion at 70% of the maximum voluntary contractions lasting 10 sec, performed before and after exposure of the upper arm to warm air flow. From probes applied over the muscle belly the following variables were recorded: total hemoglobin index (THI, SRS‐based), total hemoglobin concentration (tHb, BL‐based), tissue oxygenation index (TOI, SRS‐based), and skin blood flow (SBF), using laser Doppler flowmetry. Blood volume indices exhibited similar changes during muscle contraction but only tHb significantly increased during warming (+5.2 ± 0.7 μmol/L·cm, an effect comparable to the increase occurring in postcontraction hyperemia), accompanying a 10‐fold increase in SBF. Contraction‐induced changes in tHb and THI were not substantially affected by warming, although the tHb tracing was shifted upward by (5.2 ± 3.5 μmol/L·cm, P < 0.01). TOI was not affected by cutaneous warming. In conclusion, SRS appears to effectively reject interference by SBF in both muscle blood volume and oxygenation monitoring. Instead, BL‐based parameters should be interpreted with caution, whenever changes in cutaneous perfusion cannot be excluded. PMID:24744858
Reitsamer, Herbert A; Bogner, Barbara; Tockner, Birgit; Kiel, Jeffrey W
2009-05-01
To determine the effects of topical dorzolamide (a carbonic anhydrase inhibitor) on choroidal and ciliary blood flow and the relationship between ciliary blood flow and aqueous flow. The experiments were performed in four groups of pentobarbital-anesthetized rabbits treated with topical dorzolamide (2%, 50 microL). In all groups, intraocular pressure (IOP) and mean arterial pressure (MAP) at the eye level were measured continuously by direct cannulation. In group 1, aqueous flow was measured by fluorophotometry before and after dorzolamide treatment. In group 2, aqueous flow was measured after dorzolamide at normal MAP and while MAP was held constant at 80, 55, or 40 mm Hg with occluders on the aorta and vena cava. In group 3, the same MAP levels were used, and ciliary blood flow was measured transsclerally by laser Doppler flowmetry (LDF). In group 4, choroidal blood flow was measured by LDF with the probe tip positioned in the vitreous over the posterior pole during ramp increases and decreases in MAP before and after dorzolamide. Dorzolamide lowered IOP by 19% (P < 0.01) and aqueous flow by 17% (P < 0.01), and increased ciliary blood flow by 18% (P < 0.01), which was associated with a significant reduction in ciliary vasculature resistance (-7%, P < 0.01). Dorzolamide shifted the relationship between ciliary blood flow and aqueous flow downward relative to the previously determined control relationship in the rabbit. Dorzolamide did not alter choroidal blood flow, choroidal vascular resistance, or the choroidal pressure flow relationship. Acute topical dorzolamide is a ciliary vasodilator and has a direct inhibitory effect on aqueous production, but it does not have a detectable effect on choroidal hemodynamics at the posterior pole in the rabbit.
Age‐related differences in postsynaptic increases in sweating and skin blood flow postexercise
Stapleton, Jill M.; Fujii, Naoto; McGinn, Ryan; McDonald, Katherine; Kenny, Glen P.
2014-01-01
Abstract The influence of peripheral factors on the control of heat loss responses (i.e., sweating and skin blood flow) in the postexercise period remains unknown in young and older adults. Therefore, in eight young (22 ± 3 years) and eight older (65 ± 3 years) males, we examined dose‐dependent responses to the administration of acetylcholine (ACh) and methacholine (MCh) for sweating (ventilated capsule), as well as to ACh and sodium nitroprusside (SNP) for cutaneous vascular conductance (CVC, laser‐Doppler flowmetry, % of max). In order to assess if peripheral factors are involved in the modulation of thermoeffector activity postexercise, pharmacological agonists were perfused via intradermal microdialysis on two separate days: (1) at rest (DOSE) and (2) following a 30‐min bout of exercise (Ex+DOSE). No differences in sweat rate between the DOSE and Ex+DOSE conditions at either ACh or MCh were observed for the young (ACh: P =0.992 and MCh: P =0.710) or older (ACh: P =0.775 and MCh: P =0.738) adults. Similarly, CVC was not different between the DOSE and Ex+DOSE conditions for the young (ACh: P =0.123 and SNP: P =0.893) or older (ACh: P =0.113 and SNP: P =0.068) adults. Older adults had a lower sweating response for both the DOSE (ACh: P =0.049 and MCh: P =0.006) and Ex+DOSE (ACh: P =0.050 and MCh: P =0.029) conditions compared to their younger counterparts. These findings suggest that peripheral factors do not modulate postexercise sweating and skin blood flow in both young and older adults. Additionally, sweat gland function is impaired in older adults, albeit the impairments were not exacerbated during postexercise recovery. PMID:25347861
Rogerson, David; McNeill, Scott; Könönen, Heidi; Klonizakis, Markos
2018-05-01
The microvascular benefits of regional diets appear in the literature; however, little is known about Nordic-type diets. We investigated the effects of a short-term, adapted, Nordic diet on microvascular function in younger and older individuals at rest and during activity. Thirteen young (mean age: 28 y; standard deviation: 5 y) and 15 older (mean age: 68 y; standard deviation: 6 y) participants consumed a modified Nordic diet for 4 wk. Laser Doppler flowmetry and transcutaneous oxygen monitoring were used to assess cutaneous microvascular function and oxygen tension pre- and postintervention; blood pressure, body mass, body fat percentage, ratings of perceived exertion, and peak heart rate during activity were examined concurrently. Axon-mediated vasodilation improved in older participants (1.17 [0.30] to 1.30 [0.30]; P < 0.05). Improvements in endothelium-dependent vasodilation were noted in both young (1.67 [0.50] to 2.03 [0.62]; P < 0.05) and older participants (1.49 [0.37] to 1.63 [0.39]; P < 0.05). Reduced peak heart rate during activity was noted in older participants only (36.5 [8.9] to 35.3 [8.5]; P < 0.05) and reduced body fat percentage in young participants only (young = 27.2 [8.3] to 25.2 [8.8]; P < 0.05). No other variables reached statistical significance; however, trends were observed. We observed statistically significant improvements in microvascular function, peak heart rate, and body composition. An adapted Nordic diet might improve microvascular health. Copyright © 2017 Elsevier Inc. All rights reserved.
First-aid with warm water delays burn progression and increases skin survival.
Tobalem, M; Harder, Y; Tschanz, E; Speidel, V; Pittet-Cuénod, B; Wettstein, R
2013-02-01
First aid treatment for thermal injuries with cold water removes heat and decreases inflammation. However, perfusion in the ischemic zone surrounding the coagulated core can be compromised by cold-induced vasoconstriction and favor burn progression. The aim of this study is to evaluate the effect of local warming on burn progression in the rat comb burn model. 24 male Wistar rats were randomly assigned to either no treatment (control) or application of cold (17 °C) or warm (37 °C) water applied for 20 min. Evolution of burn depth, interspace necrosis, and microcirculatory perfusion were assessed with histology, planimetry, respectively with Laser Doppler flowmetry after 1 h, as well as 1, 4, and 7 days. Consistent conversion from a superficial to a deep dermal burn within 24 h was obtained in control animals. Warm and cold water significantly delayed burn depth progression, however after 4 days the burn depth was similar in all groups. Interspace necrosis was significantly reduced by warm water treatment (62±4% vs. 69±5% (cold water) and 82±3% (control); p<0.05). This was attributed to the significantly improved perfusion after warming, which was present 1 h after burn induction and was maintained thereafter (103±4% of baseline vs. 91±3% for cold water and 80±2% for control, p<0.05). In order to limit damage after burn injury, burn progression has to be prevented. Besides delaying burn progression, the application of warm water provided an additional benefit by improving the microcirculatory perfusion, which translated into increased tissue survival. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Simulated Microgravity Increases Cutaneous Blood Flow in the Head and Leg of Humans
NASA Technical Reports Server (NTRS)
Stout, M. Shannon; Watenpaugh, Donald E.; Breit, Gregory A.; Hargens, Alan R.
1995-01-01
The cutaneous microcirculation vasodilates during acute 6 degree head-down tilt (HDT, simulated microgravity) relative to upright conditions, more in the lower body than in the upper body. Cutaneous microvascular blood flow was measured with laser-Doppler flowmetry at the leg (over the distal tibia) and cheek (over the zygomatic arch) of eight healthy men before, during, and after 24 h of HDT. Results were calculated as a percentage of baseline value (100% measured during pre-tilt upright sitting). Cutaneous blood flow in the cheek increased significantly to 165 +/- 37% (mean +/- SE, p less than 0.05) at 9-12 h HDT, then returned to near baseline values by 24 h HDT (114 +/- 29%, NSD), despite increased local arterial pressure. Microvascular flow in the leg remained significantly elevated above baseline througout 24 h HDT (427 +/- 85% at 3 h HDT and 215 +/- 142% at 24 h HDT, p less than 0.05). During the 6-h upright sitting recovery period, cheek and leg blood flow levels returned to near pre-tilt baseline values. Because hydrostatic effects of HDT increase local arterial pressure at the carotid sinus, baroreflex-mediated withdrawal of sympathetic tone probably contributed to increased microvascular flows at the head and leg during HDT. In the leg baroreflex effects combined with minimal stimulation of local veno-arteriolar and myogenic autoregulatory vasoconstriction to elicit relatively larger and more sustained increases in cutaneous flow during HDT. In the cheek, delayed myogenic vasoconstriction and/or hurmonal effects apparently compensated for flow elevation by 24 h of HDT. Therefore, localized vascular adaptations to gravity probably explain differences in acclimation of lower and upper body blood flow to HDT and actual microgravity.
Cutaneous vascular and core temperature responses to sustained cold exposure in hypoxia.
Simmons, Grant H; Barrett-O'Keefe, Zachary; Minson, Christopher T; Halliwill, John R
2011-10-01
We tested the effect of hypoxia on cutaneous vascular regulation and defense of core temperature during cold exposure. Twelve subjects had two microdialysis fibres placed in the ventral forearm and were immersed to the sternum in a bathtub on parallel study days (normoxia and poikilocapnic hypoxia with an arterial O(2) saturation of 80%). One fibre served as the control (1 mM propranolol) and the other received 5 mM yohimbine (plus 1 mM propranolol) to block adrenergic receptors. Skin blood flow was assessed at each site (laser Doppler flowmetry), divided by mean arterial pressure to calculate cutaneous vascular conductance (CVC), and scaled to baseline. Cold exposure was first induced by a progressive reduction in water temperature from 36 to 23°C over 30 min to assess cutaneous vascular regulation, then by clamping the water temperature at 10°C for 45 min to test defense of core temperature. During normoxia, cold stress reduced CVC in control (-44 ± 4%) and yohimbine sites (-13 ± 7%; both P < 0.05 versus precooling). Hypoxia caused vasodilatation prior to cooling but resulted in greater reductions in CVC in control (-67 ± 7%) and yohimbine sites (-35 ± 11%) during cooling (both P < 0.05 versus precooling; both P < 0.05 versus normoxia). Core cooling rate during the second phase of cold exposure was unaffected by hypoxia (-1.81 ± 0.23°C h(-1) in normoxia versus -1.97 ± 0.33°C h(-1) in hypoxia; P > 0.05). We conclude that hypoxia increases cutaneous (non-noradrenergic) vasoconstriction during prolonged cold exposure, while core cooling rate is not consistently affected.
Koudijs, Suzanne M; van der Grond, Jeroen; Hoogendoorn, Mechteld L C; Hulshoff Pol, Hilleke E; Schnack, Hugo G; Witkamp, Theo D; Gooskens, Rob H J M; van Nieuwenhuizen, Onno; Braun, Kees P J
2006-08-01
To evaluate cerebral abnormalities in childhood idiopathic anatomic megalencephaly (MC) by means of different magnetic resonance (MR) modalities. MRI, volumetry, spectroscopy, and cerebropetal blood flowmetry were performed in six children with idiopathic anatomic MC, and seven volunteers. MRI revealed an increased ventricular system in five of six patients. A thalamic hamartoma was found in one patient and a Chiari I malformation was found in two. Volumetric analysis showed a disproportional increase of ventricular volume but normal subarachnoid cerebrospinal fluid (CSF) volume. Supratentorial volume was disproportionally increased compared to cerebellar volume. Intracranial volume correlated significantly with skull circumference. MR spectroscopy (MRS) N-acetyl aspartate/choline (NAA/Cho) peak ratios in WM were significantly higher in patients than in controls. Choline/creatine (Cho/Cr) peak ratios in WM were significantly lower in patients. Cortical gray matter (GM) MRS ratios were unaltered. Cerebropetal flow was increased in MC, possibly related to increased brain volume. This study reveals associated developmental anomalies for idiopathic anatomic MC. A relative ventriculomegaly was found, which should not be misinterpreted as true hydrocephalus. In contrast to metabolic MC, MRS showed no severe disturbances. Total intracranial volume is correlated to skull circumference and cerebropetal blood flow.
Optimization of camera exposure durations for multi-exposure speckle imaging of the microcirculation
Kazmi, S. M. Shams; Balial, Satyajit; Dunn, Andrew K.
2014-01-01
Improved Laser Speckle Contrast Imaging (LSCI) blood flow analyses that incorporate inverse models of the underlying laser-tissue interaction have been used to develop more quantitative implementations of speckle flowmetry such as Multi-Exposure Speckle Imaging (MESI). In this paper, we determine the optimal camera exposure durations required for obtaining flow information with comparable accuracy with the prevailing MESI implementation utilized in recent in vivo rodent studies. A looping leave-one-out (LOO) algorithm was used to identify exposure subsets which were analyzed for accuracy against flows obtained from analysis with the original full exposure set over 9 animals comprising n = 314 regional flow measurements. From the 15 original exposures, 6 exposures were found using the LOO process to provide comparable accuracy, defined as being no more than 10% deviant, with the original flow measurements. The optimal subset of exposures provides a basis set of camera durations for speckle flowmetry studies of the microcirculation and confers a two-fold faster acquisition rate and a 28% reduction in processing time without sacrificing accuracy. Additionally, the optimization process can be used to identify further reductions in the exposure subsets for tailoring imaging over less expansive flow distributions to enable even faster imaging. PMID:25071956
Studies on magnetocaloric and magnetic coupling effects =
NASA Astrophysics Data System (ADS)
Amaral, Joao Cunha de Sequeira
O presente trabalho apresenta novas metodologias desenvolvidas para a analise das propriedades magneticas e magnetocaloricas de materiais, sustentadas em consideracoes teoricas a partir de modelos, nomeadamente a teoria de transicoes de fase de Landau, o modelo de campo medio molecular e a teoria de fenomeno critico. Sao propostos novos metodos de escala, permitindo a interpretacao de dados de magnetizacao de materiais numa perspectiva de campo medio molecular ou teoria de fenomeno critico. E apresentado um metodo de estimar a magnetizacao espontanea de um material ferromagnetico a partir de relacoes entropia/magnetizacao estabelecidas pelo modelo de campo medio molecular. A termodinamica das transicoes de fase magneticas de primeira ordem e estudada usando a teoria de Landau e de campo medio molecular (modelo de Bean-Rodbell), avaliando os efeitos de fenomenos fora de equilibrio e de condicoes de mistura de fase em estimativas do efeito magnetocalorico a partir de medidas magneticas. Efeitos de desordem, interpretados como uma distribuicao na interaccao magnetica entre ioes, estabelecem os efeitos de distribuicoes quimicas/estruturais nas propriedades magneticas e magnetocaloricas de materiais com transicoes de fase de segunda e de primeira ordem. O uso das metodologias apresentadas na interpretacao das propriedades magneticas de variados materiais ferromagneticos permitiu obter: 1) uma analise quantitativa da variacao de spin por iao Gadolinio devido a transicao estrutural do composto Gd5Si2Ge2, 2) a descricao da configuracao de cluster magnetico de ioes Mn na fase ferromagnetica em manganites da familia La-Sr e La-Ca, 3) a determinacao dos expoentes criticos β e δ do Niquel por metodos de escala, 4) a descricao do efeito da pressao nas propriedades magneticas e magnetocaloricas do composto LaFe11.5Si1.5 atraves do modelo de Bean-Rodbell, 5) uma estimativa da desordem em manganites ferromagneticas com transicoes de segunda e primeira ordem, 6) uma descricao de campo medio das propriedades magneticas da liga Fe23Cu77, 7) o estudo de efeitos de separacao de fase na familia de compostos La0.70-xErxSr0.30MnO3 e 8) a determinacao realista da variacao de entropia magnetica na familia de compostos de efeito magnetocalorico colossal Mn1-x-yFexCryAs.
Zhao, Joan L.; Wu, Yubo; Johnson, John M.
2011-01-01
We hypothesized that nitric oxide activation of soluble guanylyl cyclase (sGC) participates in cutaneous vasodilation during whole body heat stress and local skin warming. We examined the effects of the sGC inhibitor, 1H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one (ODQ), on reflex skin blood flow responses to whole body heat stress and on nonreflex responses to increased local skin temperature. Blood flow was monitored by laser-Doppler flowmetry, and blood pressure by Finapres to calculate cutaneous vascular conductance (CVC). Intradermal microdialysis was used to treat one site with 1 mM ODQ in 2% DMSO and Ringer, a second site with 2% DMSO in Ringer, and a third site received Ringer. In protocol 1, after a period of normothermia, whole body heat stress was induced. In protocol 2, local heating units warmed local skin temperature from 34 to 41°C to cause local vasodilation. In protocol 1, in normothermia, CVC did not differ among sites [ODQ, 15 ± 3% maximum CVC (CVCmax); DMSO, 14 ± 3% CVCmax; Ringer, 17 ± 6% CVCmax; P > 0.05]. During heat stress, ODQ attenuated CVC increases (ODQ, 54 ± 4% CVCmax; DMSO, 64 ± 4% CVCmax; Ringer, 63 ± 4% CVCmax; P < 0.05, ODQ vs. DMSO or Ringer). In protocol 2, at 34°C local temperature, CVC did not differ among sites (ODQ, 17 ± 2% CVCmax; DMSO, 18 ± 4% CVCmax; Ringer, 18 ± 3% CVCmax; P > 0.05). ODQ attenuated CVC increases at 41°C local temperature (ODQ, 54 ± 5% CVCmax; DMSO, 86 ± 4% CVCmax; Ringer, 90 ± 2% CVCmax; P < 0.05 ODQ vs. DMSO or Ringer). sGC participates in neurogenic active vasodilation during heat stress and in the local response to direct skin warming. PMID:21292837
VIP/PACAP receptor mediation of cutaneous active vasodilation during heat stress in humans
Zhao, Joan L.; Wu, Yubo; Johnson, John M.
2010-01-01
Vasoactive intestinal peptide (VIP) is implicated in cutaneous active vasodilation in humans. VIP and the closely related pituitary adenylate cyclase activating peptide (PACAP) act through several receptor types: VIP through VPAC1 and VPAC2 receptors and PACAP through VPAC1, VPAC2, and PAC1 receptors. We examined participation of VPAC2 and/or PAC1 receptors in cutaneous vasodilation during heat stress by testing the effects of their specific blockade with PACAP6–38. PACAP6–38 dissolved in Ringer's was administered by intradermal microdialysis at one forearm site while a control site received Ringer's solution. Skin blood flow was monitored by laser-Doppler flowmetry (LDF). Blood pressure was monitored noninvasively and cutaneous vascular conductance (CVC) calculated. A 5- to 10-min baseline period was followed by ∼70 min of PACAP6–38 (100 μM) perfusion at one site in normothermia and a 3-min period of body cooling. Whole body heating was then performed to engage cutaneous active vasodilation and was maintained until CVC had plateaued at an elevated level at all sites for 5–10 min. Finally, 58 mM sodium nitroprusside was perfused through both microdialysis sites to effect maximal vasodilation. No CVC differences were found between control and PACAP6–38-treated sites during normothermia (19 ± 3%max untreated vs. 20 ± 3%max, PACAP6–38 treated; P > 0.05 between sites) or cold stress (11 ± 2%max untreated vs. 10 ± 2%max, PACAP6–38 treated, P > 0.05 between sites). PACAP6–38 attenuated the increase in CVC during whole body heating when compared with untreated sites (59 ± 3%max untreated vs. 46 ± 3%max, PACAP6–38 treated, P < 0.05). We conclude that VPAC2 and/or PAC1 receptor activation is involved in cutaneous active vasodilation in humans. PMID:20395540
Cui, Li-li; Kerkelä, Erja; Bakreen, Abdulhameed; Nitzsche, Franziska; Andrzejewska, Anna; Nowakowski, Adam; Janowski, Miroslaw; Walczak, Piotr; Boltze, Johannes; Lukomska, Barbara; Jolkkonen, Jukka
2015-01-27
Intra-arterial cell infusion is an efficient delivery route with which to target organs such as the ischemic brain. However, adverse events including microembolisms and decreased cerebral blood flow were recently reported after intra-arterial cell delivery in rodent models, raising safety concerns. We tested the hypothesis that cell dose, infusion volume, and velocity would be related to the severity of complications after intra-arterial cell delivery. In this study, 38 rats were subjected to a sham middle cerebral artery occlusion (sham-MCAO) procedure before being infused with allogeneic bone-marrow mesenchymal stem cells at different cell doses (0 to 1.0 × 10(6)), infusion volumes (0.5 to 1.0 ml), and infusion times (3 to 6 minutes). An additional group (n = 4) was infused with 1.0 × 10(6) cells labeled with iron oxide for in vivo tracking of cells. Cells were infused through the external carotid artery under laser Doppler flowmetry monitoring 48 hours after sham-MCAO. Magnetic resonance imaging (MRI) was performed 24 hours after cell infusion to reveal cerebral embolisms or hemorrhage. Limb placing, cylinder, and open field tests were conducted to assess sensorimotor functions before the rats were perfused for histology. A cell dose-related reduction in cerebral blood flow was noted, as well as an increase in embolic events and concomitant lesion size, and sensorimotor impairment. In addition, a low infusion velocity (0.5 ml/6 minutes) was associated with high rate of complications. Lesions on MRI were confirmed with histology and corresponded to necrotic cell loss and blood-brain barrier leakage. Particularly cell dose but also infusion velocity contribute to complications encountered after intra-arterial cell transplantation. This should be considered before planning efficacy studies in rats and, potentially, in patients with stroke.
Effect of medication on microvascular vasodilatation in patients with systemic lupus erythematosus.
Bengtsson, Christine; Andersson, Sven E; Edvinsson, Lars; Edvinsson, Marie-Louise; Sturfelt, Gunnar; Nived, Ola
2010-12-01
The aim of this study was to investigate the microvascular responses in the skin, to local heat, iontophoretically administered acetylcholine and to sodium nitroprusside in relation to cardiovascular damage in patients with systemic lupus erythematosus (SLE) and matched controls. We also wanted to examine if the ongoing medication in SLE patients influenced this vascular response. We investigated 30 women with SLE and compared them with 20 age and sex-matched controls. The cutaneous blood flow response to local heat (+44°C), iontophoretically administered endothelium-dependent (acetylcholine), as well as independent (sodium nitroprusside) vasodilatation, was measured by laser Doppler flowmetry. Clinical data and medication were retrieved from the clinical database and patient records. The cutaneous microvascular reactivity did not differ between SLE patients and a group of matched controls nor did it correlate with cardiovascular damage [assessed by Systemic Lupus International Collaborating Clinics/American College of Rheumatology Damage Index (SLICC/ACR-DI)]. However, patients on antimalarial drugs (hydroxychloroquine n = 8 and chloroquine diphosphate n = 3) responded more strongly to sodium nitroprusside (endothelium-independent vasodilatation) compared with those without antimalarial drugs (p < 0.01). The response to acetylcholine was higher among patients on warfarin compared with those without (p < 0.05), whereas glucocorticoid use (≥5 mg daily) was associated with reduced response to acetylcholine (p < 0.05). Smokers in general tended to have a lower response to acetylcholine (p = 0.064). Smoking SLE patients versus non-smoking SLE patients had a significantly lower response to acetylcholine (p = 0.01). Medication with antimalarial drugs-enhanced endothelium-independent vasodilatation, while glucocorticoid use was associated with reduction and warfarin-treatment with enhancement of endothelium-dependent vasodilatation. Therefore, despite there is no difference in microvascular endothelium-dependent vasodilatation, other factors such as medication and smoking may affect vasodilatation in SLE patients. © 2010 The Authors. Basic & Clinical Pharmacology & Toxicology © 2010 Nordic Pharmacological Society.
Influence of cold-water immersion on limb and cutaneous blood flow after exercise.
Mawhinney, Chris; Jones, Helen; Joo, Chang Hwa; Low, David A; Green, Daniel J; Gregson, Warren
2013-12-01
This study aimed to determine the influence of cold (8°C) and cool (22°C) water immersion on femoral artery and cutaneous blood flow after exercise. Twelve men completed a continuous cycle exercise protocol at 70% peak oxygen uptake until a core temperature of 38°C was attained. Subjects were then immersed semireclined into 8°C or 22°C water to the iliac crest for 10 min or rested. Rectal and thigh skin temperature, deep and superficial muscle temperature, thigh and calf skin blood flow (laser Doppler flowmetry), and superficial femoral artery blood flow (duplex ultrasound) were measured before and up to 30 min after immersion. Indices of vascular conductance were calculated (flux and blood flow/mean arterial pressure). Reductions in rectal temperature were similar (0.6°C-0.7°C) in all three trials (P = 0.38). The mean ± SD thigh skin temperature during recovery was 25.4°C ± 3.8°C in the 8°C trial, which was lower than the 28.2°C ± 1.4°C and 33.78°C ± 1.0°C in the 22°C and control trials, respectively (P < 0.001). Recovery muscle temperature was also lowest in the 8°C trial (P < 0.01). Femoral artery conductance was similar after immersion in both cooling conditions and was lower (∼55%) compared with the control condition 30 min after immersion (P < 0.01). Similarly, there was greater thigh (P < 0.01) and calf (P < 0.05) cutaneous vasoconstriction during and after immersion in both cooling conditions relative to the control condition. Colder water temperatures may be more effective in the treatment of exercise-induced muscle damage and injury rehabilitation by virtue of greater reductions in muscle temperature and not muscle blood flow.
Lawley, Justin S; Oliver, Samuel J; Mullins, Paul G; Macdonald, Jamie H; Moore, Jonathan P
2014-06-01
The primary aim of this study was to investigate the effect of systemic poikilocapnic hypoxia on forearm cutaneous thermal hyperaemia. A secondary aim was to examine the relationship between the individual susceptibility to oxygen desaturation and cutaneous vasodilator capacity. Twelve healthy participants (seven male) were exposed to 9 h of normoxia and 12% poikilocapnic hypoxia in a temperature- and humidity-controlled environmental chamber. Skin blood flow was assessed at the ventral forearm using laser Doppler flowmetry combined with rapid local heating. After 6 min at baseline (skin temperature clamped at 33°C), local skin temperature was elevated at a rate of 0.5°C every 5 s up to 42°C to elicit a sensory axon response and then held constant for 30 min to cause a plateau. Skin blood flow was calculated as cutaneous vascular conductance [CVC; in perfusion units/mean arterial blood pressure (APU mmHg(-1))] and expressed in raw format and relative to heating at 44°C in normoxia (%CVC44). During hypoxaemia, vasodilatation was greater during the initial peak (raw, Δ0.35 APU mmHg(-1), P = 0.09; %CVC44, Δ18%, P = 0.05) and the plateau phase (raw, Δ0.55 APU mmHg(-1), P = 0.03; %CVC44, Δ26%, P = 0.02). The rate of rise in cutaneous blood flow during the initial peak was significantly greater during poikilocapnic hypoxia (P < 0.01). We observed a negative relationship between oxygen saturation in poikilocapnic hypoxia and the change in baseline (P = 0.06), initial peak (P = 0.01) and plateau phase of thermal hyperaemia (P = 0.01). Prolonged poikilocapnic hypoxia causes robust increases in CVC during both phases of thermal hyperaemia that are dependent on the oxygen saturation of the individual. © 2014 The Authors. Experimental Physiology © 2014 The Physiological Society.
Androgens influence microvascular dilation in PCOS through ET-A and ET-B receptors
Wenner, Megan M.; Taylor, Hugh S.
2013-01-01
Hyperandrogenism and vascular dysfunction often coexist in women with polycystic ovary syndrome (PCOS). We hypothesized that testosterone compromises cutaneous microvascular dilation in women with PCOS via the endothelin-1 ET-B subtype receptor. To control and isolate testosterone's effects on microvascular dilation, we administered a gonadotropin-releasing hormone antagonist (GnRHant) for 11 days in obese, otherwise healthy women [controls, 22.0 (4) yr, 36.0 (3.2) kg/m2] or women with PCOS [23 (4) yr, 35.4 (1.3) kg/m2], adding testosterone (T; 2.5 mg/day) on days 8–11. Using laser Doppler flowmetry and cutaneous microdialysis, we measured changes in skin microcirculatory responsiveness (ΔCVC) to local heating while perfusing ET-A (BQ-123) and ET-B (BQ-788) receptor antagonists under three experimental conditions: baseline (BL; prehormone intervention), GnRHant (day 4 of administration), and T administration. At BL, ET-A receptor inhibition enhanced heat-induced vasodilation in both groups [ΔCVC control 2.03 (0.65), PCOS 2.10 (0.25), AU/mmHg, P < 0.05]; ET-B receptor inhibition reduced vasodilation in controls only [ΔCVC 0.98 (0.39), 1.41 (0.45) AU/mmHg for controls, PCOS] compared with saline [ΔCVC controls 1.27 (0.48), PCOS 1.31 (0.13) AU/mmHg]. GnRHant enhanced vasodilation in PCOS [saline ΔCVC 1.69 (0.23) AU/mmHg vs. BL, P < 0.05] and abolished the ET-A effect in both groups, a response reasserted with T in controls. ET-B receptor inhibition reduced heat-induced vasodilation in both groups during GnRHant and T [ΔCVC, controls: 0.95 (0.21) vs. 0.51 (13); PCOS: 1.27 (0.23) vs. 0.84 (0.27); for GnRHant vs. T, P < 0.05]. These data demonstrate that androgen suppression improves microvascular dilation in PCOS via ET-A and ET-B receptors. PMID:23921139
Mohan, J S; Marshall, J M; Reid, H L; Thomas, P W; Hambleton, I; Serjeant, G R
1998-02-01
In normal individuals, novel or noxious stimuli commonly evoke the pattern of the alerting or defence response which includes cutaneous vasoconstriction, but vasodilatation in forearm skeletal muscle. We have compared cardiovascular responses evoked by sound and by indirect cooling in 60 patients with homozygous sickle cell (SS) disease and in 30 control subjects with normal haemoglobin genotype (AA). A sound of 90 dB, 1 kHz for 30s evoked an increase in hand and forearm cutaneous vascular resistance (HCVR and FCVR) in SS patients and an increase in HCVR in AA subjects, as assessed from Doppler flowmetry. Meanwhile, a decrease in forearm vascular resistance (FVR) assessed by venous occlusion plethysmography, occurred in 14 out of 30 AA subjects and 25 out of 60 SS patients, indicating vasodilatation in forearm muscle; an increase in FVR occurred in the remainder. The proportions of SS patients and AA subjects who showed an increase in FVR (53% vs 57%) were not significantly different. Cooling increased HCVR and FCVR in SS patients and increased FCVR in AA subjects; a decrease in FVR indicating vasodilatation, occurred in 12 out of 30 AA subjects, but in only 10 out of 60 SS patients. The proportion of SS patients who showed an increase in FVR to cooling was greater than in AA subjects (83% vs 60%, P < 0.05). Thus, SS patients are just as capable of showing the muscle vasodilatation of the alerting response to sound as AA subjects. That few SS patients showed muscle vasodilatation in response to cooling is consistent with the view that reflex vasoconstrictor responses to cooling are particularly strong in SS patients. This, in turn, is consistent with our hypothesis that the reflex vasoconstrictor response to cooling acts as a trigger for the painful crisis of SS disease by diverting blood flow away from active bone marrow.
Ethnic differences in macrovascular and microvascular function in systolic heart failure.
Shantsila, Eduard; Wrigley, Benjamin; Shantsila, Alena; Tapp, Luke D; Blann, Andrew D; Gill, Paramjit S; Lip, Gregory Y H
2011-11-01
Endothelial dysfunction is implicated in the pathophysiological features of heart failure (HF), and ethnic differences in the presentation of cardiovascular disease are evident, with an excess seen among South Asians (SAs). However, data on ethnic differences in endothelial function in HF are limited. In a cross-sectional study, we recruited 128 subjects with systolic HF: 50 SAs, 50 whites, and 28 African Caribbeans (ACs). In addition, SAs with systolic HF were compared with 40 SAs with coronary artery disease without HF ("disease controls") and 40 SA healthy controls. Macrovascular endothelial function was assessed by measurement of flow-mediated dilation (FMD) in response to hyperemia, arterial stiffness was assessed by the pulse-wave velocity, and microvascular endothelial function was assessed by forearm laser Doppler flowmetry. CD144-expressing endothelial microparticles were measured by flow cytometry. When compared with disease controls and healthy controls, SAs with HF had an impaired microvascular response to acetylcholine (P=0.001) and reduced FMD (P<0.001). In comparing ethnic groups, SAs with HF had an impaired response to acetylcholine (123±95.5%) compared with whites (258±156%) and ACs (286±173%, P<0.001 for both). Whites had a higher FMD (8.49±4.63%) than SAs (4.76±4.78%, P<0.001) and ACs (4.55±3.56%, P=0.01). No difference in endothelial-independent response was observed between study groups or in pulse-wave velocity. Ethnicity remained associated with microvascular endothelial function even after adjustment for age, presence of hypertension and diabetes mellitus, blood pressure, and glucose levels (P=0.003). There were no differences in numbers of endothelial microparticles. The SAs with HF have impaired microvascular and macrovascular endothelial function but preserved arterial elastic properties. Significant ethnic differences in endothelial function are evident in subjects with HF, with ethnicity being associated with microvascular endothelial dysfunction in this disorder.
Atochin, Dmitriy N; Schepetkin, Igor A; Khlebnikov, Andrei I; Seledtsov, Victor I; Swanson, Helen; Quinn, Mark T; Huang, Paul L
2016-04-08
The c-Jun N-terminal kinase (JNK) has been shown to be an important regulator of neuronal cell death. Previously, we synthesized the sodium salt of 11H-indeno[1,2-b]quinoxalin-11-one (IQ-1S) and demonstrated that it was a high-affinity inhibitor of the JNK family. In the present work, we found that IQ-1S could release nitric oxide (NO) during its enzymatic metabolism by liver microsomes. Moreover, serum nitrite/nitrate concentration in mice increased after intraperitoneal injection of IQ-1S. Because of these dual actions as JNK inhibitor and NO-donor, the therapeutic potential of IQ-1S was evaluated in an animal stroke model. We subjected wild-type C57BL6 mice to focal ischemia (30min) with subsequent reperfusion (48h). Mice were treated with IQ-1S (25mg/kg) suspended in 10% solutol or with vehicle alone 30min before and 24h after middle cerebral artery (MCA) occlusion (MCAO). Using laser-Doppler flowmetry, we monitored cerebral blood flow (CBF) above the MCA during 30min of MCAO provoked by a filament and during the first 30min of subsequent reperfusion. In mice treated with IQ-1S, ischemic and reperfusion values of CBF were not different from vehicle-treated mice. However, IQ-1S treated mice demonstrated markedly reduced neurological deficit and infarct volumes as compared with vehicle-treated mice after 48h of reperfusion. Our results indicate that the novel JNK inhibitor releases NO during its oxidoreductive bioconversion and improves stroke outcome in a mouse model of cerebral reperfusion. We conclude that IQ-1S is a promising dual functional agent for the treatment of cerebral ischemia and reperfusion injury. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ketel, Iris J G; Stehouwer, Coen D A; Serné, Erik H; Korsen, Ted J M; Hompes, Peter G A; Smulders, Yvo M; de Jongh, Renate T; Homburg, Roy; Lambalk, Cornelis B
2008-09-01
Polycystic ovary syndrome (PCOS) and obesity are associated with diabetes and cardiovascular disease, but it is unclear to what extent PCOS contributes independently of obesity. The objective of the study was to investigate whether insulin sensitivity and insulin's effects on the microcirculation are impaired in normal-weight and obese women with PCOS. Thirty-five women with PCOS (19 normal weight and 16 obese) and 27 age- and body mass index-matched controls (14 normal weight and 13 obese) were included. Metabolic Insulin sensitivity (isoglycemic-hyperinsulinemic clamp) and microvascular insulin sensitivity [endothelium dependent (acetylcholine [ACh])] and endothelium-independent [sodium nitroprusside (SNP)] vasodilation with laser Doppler flowmetry was assessed at baseline and during hyperinsulinemia. Metabolic insulin sensitivity (M/I value) and the area under the response curves to ACh and SNP curves were measured to assess microcirculatory function at baseline and during insulin infusion (microvascular insulin sensitivity). Obese women were more insulin resistant than normal-weight women (P < 0.001), and obese PCOS women were more resistant than obese controls (P = 0.02). In contrast, normal-weight women with PCOS had similar insulin sensitivity, compared with normal-weight women without PCOS. Baseline responses to ACh showed no difference in the four groups. ACh responses during insulin infusion were significantly greater in normal-weight PCOS and controls than in obese PCOS and controls. PCOS per se had no significant influence on ACh responses during insulin infusion. During hyperinsulinemia, SNP-dependent vasodilatation did not significantly increase, compared with baseline in the four groups. PCOS per se was not associated with impaired metabolic insulin sensitivity in normal-weight women but aggravates impairment of metabolic insulin sensitivity in obese women. In obese but not normal-weight women, microvascular and metabolic insulin sensitivity are decreased, independent of PCOS. Therefore, obese PCOS women in particular may be at increased risk of metabolic and cardiovascular diseases.
Chronic adriamycin treatment impairs CGRP-mediated functions of meningeal sensory nerves.
Deák, Éva; Rosta, Judit; Boros, Krisztina; Kis, Gyöngyi; Sántha, Péter; Messlinger, Karl; Jancsó, Gábor; Dux, Mária
2018-06-01
Adriamycin is a potent anthracycline-type antitumor agent, but it also exerts potentially serious side effects due to its cardiotoxic and neurotoxic propensity. Multiple impairments in sensory nerve functions have been recently reported in various rat models. The present experiments were initiated in an attempt to reveal adriamycin-induced changes in sensory effector functions of chemosensitive meningeal afferents. Meningeal blood flow was measured with laser Doppler flowmetry in the parietal dura mater of adult male Wistar rats. The dura mater was repeatedly stimulated by topical applications of capsaicin, a transient receptor potential vanilloid 1 (TRPV1) receptor agonist, or acrolein, a transient receptor potential ankyrin 1 (TRPA1) receptor agonist, which induce the release of calcitonin gene-related peptide (CGRP) from meningeal afferents. The blood flow increasing effects of CGRP, histamine, acetylcholine and forskolin were also measured. Capsaicin- and acrolein-induced CGRP release was measured with enzyme-linked immunoassay in an ex vivo dura mater preparation. TRPV1 content of trigeminal ganglia and TRPV1-, CGRP- and CGRP receptor component-immunoreactive structures were examined in dura mater samples obtained from control and adriamycin-treated rats. The vasodilator effects of capsaicin, acrolein and CGRP were significantly reduced in adriamycin-treated animals while histamine-, acetylcholine- and forskolin-induced vasodilatation were unaffected. Measurements of CGRP release in an ex vivo dura mater preparation revealed an altered dynamic upon repeated stimulations of TRPV1 and TRPA1 receptors. In whole-mount dura mater preparations immunohistochemistry revealed altered CGRP receptor component protein (RCP)-immunoreactivity in adriamycin-treated animals, while CGRP receptor activity modifying protein (RAMP1)-, TRPV1- and CGRP-immunostaining were left apparently unaltered. Adriamycin-treatment slightly reduced TRPV1 protein content of trigeminal ganglia. The present findings demonstrate that adriamycin-treatment alters the function of the trigeminovascular system leading to reduced meningeal sensory neurogenic vasodilatation that may affect the local regulatory and protective mechanisms of chemosensitive afferents leading to alterations in tissue integrity. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Breit, G. A.; Watenpaugh, D. E.; Buckley, T. M.; Ballard, R. E.; Murthy, G.; Hargens, A. R.
1994-01-01
The response of the cutaneous microcirculation to orthostatic stress varies along the length of the body due to the interaction of central controls with regional responses to local blood pressure. We hypothesize that artificial orthostatic stresses such as Gz centrifugation and LBNP differ from whole-body tilting in terms of the distribution of microvascular blood flow. Cutaneous microvascular flows were measured by laser Doppler flowmetry at the neck, thigh, and leg of 15 normal subjects. Volunteers underwent stepwise head-up tilt (HUT) and short- and long-arm centrifugation protocols from supine control (0 Gz) to 0.2, 0.4, 0.6, 0.8, 1.0, 0.8, 0.6, 0.4, 0.2, and 0 Gz at the feet, for 30-s periods with 10-s transitions between levels. The same subjects underwent a corresponding supine LBNP protocol, up to 100 mmHg (in 20 mmHg increments) and back to zero pressure, which produced transmural pressure across blood vessels in the foot approximately equal to the HUT protocol. In general, application of all orthostatic stresses produced significant flow reductions in the lower body (p less than 0.05) and inconsistent changes in the neck. At low levels of each stress (0.4 Gz, 40 mmHg), LBNP generated the greatest relative reduction in flow in the lower body (-66.9+/-5.7%, thigh; -60.6 +/-5.7%, leg, mean +/- SE). HUT caused a less severe flow reduction than LBNP at the thigh and leg (-39.9 +/- 8.1% and -55.9+/-4.8%), while the effects induced by both forms of centrifugation were the least profound. Higher levels of each stress generally resulted in similar responses. These responses exhibit a consistent relationship to hypothesized changes in local microvascular transmural pressure, suggesting that myogenic and veno-arteriolar reflexes play a significant role in determining microvascular perfusion during orthostatic stress.
Sprung, V S; Cuthbertson, D J; Pugh, C J A; Daousi, C; Atkinson, G; Aziz, N F; Kemp, G J; Green, D J; Cable, N T; Jones, H
2013-03-15
Polycystic ovary syndrome (PCOS) is associated with cardiovascular disease. The contribution of the nitric oxide (NO) dilator system to cutaneous endothelial dysfunction is currently unknown in PCOS. Our aim was to examine whether women with PCOS demonstrate impaired cutaneous microvascular NO function and whether exercise training can ameliorate any impairment. Eleven women with PCOS (age, 29 ± 7 years; body mass index, 34 ± 6 kg m(-2)) were compared with six healthy obese control women (age, 29 ± 7 years; body mass index, 34 ± 5 kg m(-2)). Six women with PCOS (30 ± 7 years; 31 ± 6 kg m(-2)) then completed 16 weeks of exercise training. Laser Doppler flowmetry, combined with intradermal microdialysis of l-N(G)-monomethyl-l-arginine, a nitric oxide antagonist, in response to incremental local heating of the forearm was assessed in women with PCOS and control women, and again in women with PCOS following exercise training. Cardiorespiratory fitness, homeostasis model assessment for insulin resistance, hormone and lipid profiles were also assessed. Differences between women with PCOS and control women and changes with exercise were analysed using Student's unpaired t tests. Differences in the contribution of NO to cutaneous blood flow [expressed as a percentage of maximal cutaneous vasodilatation (CVCmax)] were analysed using general linear models. At 42°C heating, cutaneous NO-mediated vasodilatation was attenuated by 17.5%CVCmax (95% confidence interval, 33.3, 1.7; P = 0.03) in women with PCOS vs. control women. Exercise training improved cardiorespiratory fitness by 5.0 ml kg(-1) min(-1) (95% confidence interval, 0.9, 9.2; P = 0.03) and NO-mediated cutaneous vasodilatation at 42°C heating by 19.6% CVCmax (95% confidence interval, 4.3, 34.9; P = 0.02). Cutaneous microvascular NO function is impaired in women with PCOS compared with obese matched control women but can be improved with exercise training.
Gryglewska, Barbara; Nęcki, Mirosław; Cwynar, Marcin; Baron, Tomasz; Grodzicki, Tomasz
2010-12-01
The aim of the study was to investigate the skin microcirculation blood flow and flowmotion response to heat stress in normotensive subjects with familial predisposition to hypertension and in hypertensive patients. Normotensives without [NT(-)] or with [NT(+)] familial predisposition and subjects with newly diagnosed hypertension (HT) were studied. Clinic blood pressure (BP) measurements and ambulatory BP monitoring as well as laboratory assessments were performed. Resting (RF), heat (HF) and maximal heat (MHF) blood flows were measured using PeriFlux laser Doppler flowmetry (LDF) and expressed as absolute units (AU) and as index of cutaneous vascular conductance (CVC). Spectral analysis of the skin LDF signal was performed by means of the Perisoft dedicated software. Kruskall-Wallis analysis of variance, χ(2) statistic and multivariate reverse regression analysis were used for calculation. The studied population consisted of 70 persons (mean age 36.1 ± 10.3 years, 44.3% women): 17 NT(-), 22 NT(+) and 31 HT, age and gender matched. Higher values of body mass index (BMI), and insulin, glucose and triglyceride levels were observed in HT than in NT groups. RF, HF and MHF were similar in all study groups, but CVC of maximal heat flow differed (p=0.02); in particular, lower values were observed in the HT than in NT(-) group (p=0.01). The study groups differed with regard to total power (p=0.01) and myogenic (p=0.03) origin flowmotion with the lowest values in the NT(+) group. BMI and night BP characteristics were strong predictors of reduction of CVC, MHF and myogenic origin flowmotion. Skin microcirculation response to local heat stress is altered in hypertensive patients with decrease in maximal heat CVC values. Moreover, normotensive subjects with familial predisposition to hypertension are characterized by diminished myogenic origin of skin blood flowmotion.
Muscle metaboreceptor modulation of cutaneous active vasodilation
NASA Technical Reports Server (NTRS)
Crandall, C. G.; Stephens, D. P.; Johnson, J. M.
1998-01-01
PURPOSE: Isometric handgrip exercise in hyperthermia has been shown to reduce cutaneous vascular conductance (CVC) by inhibiting the cutaneous active vasodilator system. METHODS: To identify whether this response was initiated by muscle metaboreceptors, in seven subjects two 3-min bouts of isometric handgrip exercise in hyperthermia were performed, followed by 2 min of postexercise ischemia (PEI). An index of forearm skin blood flow (laser-Doppler flowmetry) was measured on the contralateral arm at an unblocked site and at a site at which adrenergic vasoconstrictor function was blocked via bretylium iontophoresis to reveal active cutaneous vasodilator function unambiguously. Sweat rate was measured via capacitance hygrometry, CVC was indexed from the ratio of skin blood flow to mean arterial pressure and was expressed as a percentage of maximal CVC at that site. In normothermia, neither isometric exercise nor PEI affected CVC (P > 0.05). RESULTS: The first bout of isometric handgrip exercise in hyperthermia reduced CVC at control sites and this reduction persisted through PEI (pre-exercise: 59.8 +/- 5.4, exercise: 49.8 +/- 4.9, PEI: 49.7 +/- 5.3% of maximum; both P < 0.05), whereas there were no significant changes in CVC at the bretylium treated sites. The succeeding bout of isometric exercise in hyperthermia significantly reduced CVC at both untreated (pre-exercise: 59.0 +/- 4.8, exercise: 47.3 +/- 4.0, PEI: 50.1 +/- 4.1% of maximum; both P < 0.05) and bretylium treated sites (pre-exercise: 61.4 +/- 7.3, exercise: 50.6 +/- 5.1, PEI: 53.9 +/- 6.0% of maximum, both P < 0.05). At both sites, CVC during PEI was lower than during the pre-exercise period (P < 0.05). Sweat rate rose significantly during both bouts of isometric exercise and remained elevated during PEI. CONCLUSIONS: These data suggest that the reduction in CVC during isometric exercise in hyperthermia, including the inhibition of the active vasodilator system, is primarily mediated by muscle metaboreceptors, whereas central command or muscle mechanoreceptors have less influence.
Comparative effects of glycerol and Urografin on cochlear blood flow and serum osmolarity.
Noi, O; Makimoto, K
1998-09-01
Glycerol, an osmotic diuretic, has been used for the diagnosis and treatment of endolymphatic hydrops. Hearing improvements in hydropic ears are attributed to its dehydrating effect. In addition to this effect, glycerol also increases cochlear blood flow. Urografin, another hyperosmotic agent used for vasography, is similarly known to increase local blood flow. The present study compared these two hyperosmotic agents, glycerol and Urografin, in their effects on cochlear blood flow and serum osmolarity. Laser Doppler flowmetry on the lateral wall of the cochlea revealed that the increase in cochlear blood flow with a 30-min infusion (0.025 ml/min) of 76% Urografin continued for a longer time than with a 30-min infusion (0.025 ml/min) of 50% (v/v) glycerol. The significant increases appeared at 20 and 30 min after the infusion with the former; 10, 20, 30, 40, 50 and 60 min after the infusion with the latter. Intravenous infusion of these agents also caused elevation in serum osmolarity. This elevation was appreciably greater with Urografin infusion (maximal increase: about 30 mOsm on average) than with glycerol infusion (maximal increase: about 6 mOsm on average), and the former elevation appeared to be longer lasting than the latter. These differences were ascribed to differences between glycerol and Urografin with respect to the creation of an osmotic gradient across the capillary walls of cochlear blood vessels. Since glycerol penetrates the interstitial space and moves into inner ear fluids, the gradient may decline faster. It would be assumed that a higher concentration of the hyperosmotic agent in the capillary blood causes more vasodilatation and lowering of blood viscosity. Alternatively, direct action of these agents on the vascular wall may affect some biological processes, leading to vasodilatation in different degrees and durations with different agents. Hearing improvement with glycerol administration in hydropic ears was also discussed from the perspective of cochlear blood flow.
NASA Astrophysics Data System (ADS)
Deutsch, Assaf; Pevzner, Eliyahu; Jaronkin, Alex; Mayevsky, Avraham
2004-06-01
Monitoring of tissue vitality (oxygen supply/demand) in real time is very rare in clinical practice although its use as an early warning alarming system, for clinical care medicine, is very practical. In our previous communication (SPIE 2003) we described the Tissue Spectroscope - TiSpec02, by which tissue microcirculatory blood flow (TBF) and mitochondrial NADH fluorescence were measured using a single light source (390nm). In order to improve the measurement capabilities as well as to decrease dramatically the size and cost of this clinical device, we have changed the TiSpec02 into a multi-wavelength illumination system in the new TiSpec03. In order to measure microcirculatory blood flow by laser Doppler flowmetry we used a 785nm laser diode. For mitochondrial NADH fluorescence measurement we adopted the 370nm LED. For the determination of the oxygenation level of hemoglobin (HbO2) we used the 2-wavelength reflectance technique. This new monitored parameter that was added to the TiSpec03 increases the accuracy of the diagnosis of tissue vitality. The bundle of optical fibers used to connect the tissue to the TiSpec03, was integrated into a special anchoring methodology depending on the monitored tissue or organ. In order to test the performance of the improved TiSpec we have used it in experimental animals brain models exposed to various pathophysiological conditions. Rats and gerbils were anesthetized and the fiber optic probe was located epidurally used dental acrylic cement. During anoxia and ischemia the lack of O2 led to a clear decrease in TBF and HbO2 while NADH shows a large elevation. When brain activation was induced by cortical spreading depression (SD), the elevated O2 consumption was recorded as a large oxidation (decrease) of mitochondrial NADH while TBF increase dramatically. Blood HbO2 was not affected significantly by the SD wave.
Yang, Wei; Chen, Quanyu; Xia, Renpei; Zhang, Yujun; Shuai, Ling; Lai, Jiejuan; You, Xiaolin; Jiang, Yan; Bie, Ping; Zhang, Leida; Zhang, Hongyu; Bai, Lianhua
2018-05-28
Naïve decellularized liver scaffold (nDLS)-based tissue engineering has been impaired by the lack of a suitable extracellular matrix (ECM) to provide "active micro-environmental" support. The present study aimed to examine whether a novel, regenerative DLS (rDLS) with an active ECM improves primary hepatocyte survival and prevents thrombosis. rDLS was obtained from a 30-55% partial hepatectomy that was maintained in vivo for 3-5 days and then perfused with detergent in vitro. Compared to nDLS generated from normal livers, rDLS possesses bioactive molecules due to the regenerative period in vivo. Primary mouse hepatocyte survival was evaluated by staining for Ki-67 and Trypan blue exclusion. Thrombosis was assessed by immunohistochemistry and ex vivo diluted whole-blood perfusion. Hemocompatibility was determined by near-infrared laser-Doppler flowmetry and heterotopic transplantation. After recellularization, rDLS contained more Ki-67-positive primary hepatocytes than nDLS. rDLS had a higher oxygen saturation and blood flow velocity and a lower expression of integrin αIIb and α4 than nDLS. Tumor necrosis factor-α, hepatocyte growth factor, interleukin-10, interleukin-6 and interleukin-1β were highly expressed throughout the rDLS, whereas expression of collagen-I, collagen-IV and thrombopoietin were lower in rDLS than in nDLS. Improved blood vessel patency was observed in rDLS both in vitro and in vivo. The results in mice were confirmed in large animals (pigs). rDLS is an effective DLS with an "active microenvironment" that supports primary hepatocyte survival and promotes blood vessel patency. This is the first study to demonstrate a rDLS with a blood microvessel network that promotes hepatocyte survival and resists thrombosis. Copyright © 2018 Elsevier Ltd. All rights reserved.
Greaney, Jody L; DuPont, Jennifer J; Lennon-Edwards, Shannon L; Sanders, Paul W; Edwards, David G; Farquhar, William B
2012-01-01
Animal studies have reported dietary salt-induced reductions in vascular function independent of increases in blood pressure (BP). The purpose of this study was to determine if short-term dietary sodium loading impairs cutaneous microvascular function in normotensive adults with salt resistance. Following a control run-in diet, 12 normotensive adults (31 ± 2 years) were randomized to a 7 day low-sodium (LS; 20 mmol day−1) and 7 day high-sodium (HS; 350 mmol day−1) diet (controlled feeding study). Salt resistance, defined as a ≤5 mmHg change in 24 h mean BP determined while on the LS and HS diets, was confirmed in all subjects undergoing study (LS: 84 ± 1 mmHg vs. HS: 85 ± 2 mmHg; P > 0.05). On the last day of each diet, subjects were instrumented with two microdialysis fibres for the local delivery of Ringer solution and 20 mm ascorbic acid (AA). Laser Doppler flowmetry was used to measure red blood cell flux during local heating-induced vasodilatation (42°C). After the established plateau, 10 mm l-NAME was perfused to quantify NO-dependent vasodilatation. All data were expressed as a percentage of maximal cutaneous vascular conductance (CVC) at each site (28 mm sodium nitroprusside; 43°C). Sodium excretion increased during the HS diet (P < 0.05). The plateau % CVCmax was reduced during HS (LS: 93 ± 1 % CVCmax vs. HS: 80 ± 2 % CVCmax; P < 0.05). During the HS diet, AA improved the plateau % CVCmax (Ringer: 80 ± 2 % CVCmax vs. AA: 89 ± 3 % CVCmax; P < 0.05) and restored the NO contribution (Ringer: 44 ± 3 % CVCmax vs. AA: 59 ± 6 % CVCmax; P < 0.05). These data demonstrate that dietary sodium loading impairs cutaneous microvascular function independent of BP in normotensive adults and suggest a role for oxidative stress. PMID:22907057
Strömberg, Tomas; Sjöberg, Folke; Bergstrand, Sara
2017-09-01
Forearm skin hyperemia during release after brachial occlusion has been proposed for evaluating peripheral arterial disease and endothelial dysfunction. We used a novel fiberoptic system integrating Laser Doppler Flowmetry and Diffuse Reflectance Spectroscopy for a comprehensive pointwise model based microcirculation characterization. The aim was to evaluate and compare the temporal and the spatiotemporal variabilities in forearm skin microcirculation parameters (speed resolved perfusion; low speed <1mm/s, Perf SR, <1 ; mid-speed 1-10mm/s, high speed >10mm/s, and total perfusion (Perf SR, tot ); the concentration and oxygenation of red blood cells, C RBC and S O2 ). Ten healthy subjects underwent arterial and venous forearm occlusions (AO, VO), repeated within one week. The repeatability was calculated as the coefficient of variation (CV) and the agreement as the intra-class correlation coefficient (ICC). The temporal CVs for conventional perfusion, Perf conv , Perf SR, tot , C RBC and S O2 were 14%, 12%, 9% and 9%, respectively, while the ICC were >0.75 (excellent). The perfusion measures generally had a higher spatiotemporal than temporal variability, which was not the case for S O2 and C RBC . The corresponding spatiotemporal CVs were 33%, 32%, 18% and 15%, respectively. During VO, C RBC had a CV<35% and ICC>0.40 (fair-good), and after release this was the case for C RBC (AO and VO), S O2 (VO) and Perf SR, <1 (VO). In conclusion, the skin microcirculation parameters showed excellent temporal repeatability, while the spatiotemporal repeatability especially for perfusion was poorer. The parameters with acceptable repeatability and fair-good agreement were: C RBC during and after release of VO, the Perf SR, <1 after release of VO, the S O2 and the C RBC after release of AO. However, the value of these parameters in discriminating endothelial function remains to be studied. Copyright © 2017 Elsevier Inc. All rights reserved.
Harukuni, I; Takahashi, H; Traystman, R J; Bhardwaj, A; Kirsch, J R
2000-01-01
We tested the following hypotheses: a) spontaneously hypertensive stroke-prone rats (SHR-SP) have more brain injury than spontaneously hypertensive rats (SHR) and normotensive controls (Wistar-Kyoto rats [WKY]) when exposed to transient focal ischemia; b) infarction size is not correlated with baseline blood pressure; and c) infarction size is inversely related to the cerebral hyperemic response to oxotremorine, a muscarinic agonist that increases cerebral blood flow (CBF) by stimulating endothelial nitric oxide synthase. In vivo study. Animal laboratory in a university teaching hospital. Adult age-matched male WKY, SHR, and SHR-SP. Rats were instrumented under halothane anesthesia. Transient focal cerebral ischemia was produced for 2 hrs with the intravascular suture technique. Cerebral perfusion, estimated with laser Doppler flowmetry (LD-CBF), in response to intravenous oxotremorine, was measured in one cohort of rats to estimate endothelial nitric oxide synthase function. Infarction volume was measured at 22 hrs of reperfusion with 2,3,5-triphenyltetrazolium chloride staining. Infarction volume in the striatum of SHR-SP (42+/-4 mm3) was greater than in SHR (29+/-6 mm3) or WKY (1+/-1 mm3) (n = 9 rats/strain). Resting (unanesthetized) mean arterial blood pressure was similar in SHR-SP (177+/-5 mm Hg) and SHR (170+/-5 mm Hg) despite a greater infarction volume in SHR-SP (n = 4) compared with SHR (n = 5). The percentage increase in LD-CBF signal in response to oxotremorine was similar for both groups (SHR, 64%+/-22% [n = 10]; SHR-SP, 69%+/-22% [n = 8]). However, in this cohort, cortical infarction volume was less in SHR (30%+/-4% of ipsilateral cortex) than in SHR-SP (49%+/-2% of ipsilateral cortex). Although SHR-SP have greater infarction volume than SHR, the mechanism of injury does not appear to be related to a difference in unanesthetized baseline mean arterial blood pressure or to an alteration in endothelium-produced nitric oxide.
Akhoundzadeh, Kobar; Vakili, Abedin; Sameni, Hamid Reza; Vafaei, Abbas Ali; Rashidy-Pour, Ali; Safari, Manouchehr; Mohammadkhani, Razieh
2017-08-01
This study examined whether post-stroke bone marrow stromal cells (BMSCs) therapy combined with exercise (EX) and/or thyroid hormone (TH) could reduce brain damage in an experimental ischemic stroke in mice. Focal cerebral ischemia was induced under Laser Doppler Flowmetry (LDF) guide by 45 min of middle cerebral artery occlusion (MCAO), followed by 7 days of reperfusion in albino mice. BMSCs were injected into the right cerebral ventricle 24 h after MCAO, followed by daily injection of T3 (20 μg/100 g weight S.C) and 6 days of running on a treadmill. Infarct size, neurobehavioral test, TUNEL and BrdU positive cells were evaluated at 7 days after MCAO. Treatment with BMSCs and mild EX alone significantly reduced the infarct volume by 23% and 44%, respectively (both, p < 0.001). The BMSCs + TH, BMSCs + EX, and BMSCs + EX + TH combination therapies significantly reduced the infarct volume by 26%, 51%, and 70%, respectively (all, p < 0.001). A significant improvement in the neurobehavioral functioning was observed in the EX, BMSCs + EX, and BMSCs + EX+ TH groups (p < 0.001). The number of TUNEL-positive cells (a marker of apoptosis) was significantly reduced in the EX, BMSCs, BMSCs + EX, BMSCs + TH, and BMSCs + EX + TH groups (all, p < 0.001). Moreover, the combination therapy considerably increased BrdU-labeled cells in the subventricular zone (SVZ) (p < 0.01). Our findings indicated that the combined treatment of BMSCs with mild EX and TH more efficiently reduces the cerebral infarct size after stroke. More likely, these effects mediate via enchaining generation of new neuronal cells and the attenuation of apoptosis in ischemia stroke in young mice.
Fuchsjäger-Mayrl, G; Wally, B; Rainer, G; Buehl, W; Aggermann, T; Kolodjaschna, J; Weigert, G; Polska, E; Eichler, H-G; Vass, C; Schmetterer, L
2005-01-01
Background: There is evidence that perfusion abnormalities of the optic nerve head are involved in the pathogenesis of glaucoma. There is therefore considerable interest in the effects of topical antiglaucoma drugs on ocular blood flow. A study was undertaken to compare the ocular haemodynamic effects of dorzolamide and timolol in patients with primary open angle glaucoma (POAG) or ocular hypertension (OHT). Methods: One hundred and forty patients with POAG or OHT were included in a controlled, randomised, double blind study in two parallel groups; 70 were randomised to receive timolol and 70 to receive dorzolamide for a period of 6 months. Subjects whose intraocular pressure (IOP) did not respond to either of the two drugs were switched to the alternative treatment after 2 weeks. Scanning laser Doppler flowmetry was used to measure blood flow in the temporal neuroretinal rim and the cup of the optic nerve head. Pulsatile choroidal blood flow was assessed using laser interferometric measurement of fundus pulsation amplitude. Results: Five patients did not respond to timolol and were changed to the dorzolamide group, and 18 patients changed from dorzolamide treatment to timolol. The effects of both drugs on IOP and ocular perfusion pressure were comparable. Dorzolamide, but not timolol, increased blood flow in the temporal neuroretinal rim (8.5 (1.6)%, p<0.001 versus timolol) and the cup of the optic nerve head (13.5 (2.5)%, p<0.001 versus timolol), and fundus pulsation amplitude (8.9 (1.3)%, p<0.001 versus timolol). Conclusions: This study indicates augmented blood flow in the optic nerve head and choroid after 6 months of treatment with dorzolamide, but not with timolol. It remains to be established whether this effect can help to reduce visual field loss in patients with glaucoma. PMID:16170119
Jennings, John D.; Lang, James A.; Kenney, W. Larry
2009-01-01
In young healthy humans full expression of reflex cutaneous vasodilation is dependent on cyclooxygenase (COX)- and nitric oxide synthase (NOS)-dependent mechanisms. Chronic low-dose aspirin therapy attenuates reflex cutaneous vasodilation potentially through both platelet and vascular COX-dependent mechanisms. We hypothesized the contribution of COX-dependent vasodilators to reflex cutaneous vasodilation during localized acute COX inhibition would be attenuated in healthy middle-aged humans due to a shift toward COX-dependent vasoconstrictors. Four microdialysis fibers were placed in forearm skin of 13 middle-aged (53 ± 2 yr) normotensive healthy humans, serving as control (Ringer), COX-inhibited (10 mM ketorolac), NOS-inhibited (10 mM NG-nitro-l-arginine methyl ester), and combined NOS- and COX-inhibited sites. Red blood cell flux was measured over each site by laser-Doppler flowmetry as reflex vasodilation was induced by increasing oral temperature (Tor) 1.0°C using a water-perfused suit. Cutaneous vascular conductance was calculated (CVC = flux/mean arterial pressure) and normalized to maximal CVC (CVCmax; 28 mM sodium nitroprusside). CVCmax was not affected by localized microdialysis drug treatment (P > 0.05). Localized COX inhibition increased baseline (18 ± 3%CVCmax; P < 0.001) compared with control (9 ± 1%CVCmax), NOS-inhibited (7 ± 1%CVCmax), and combined sites (10 ± 1%CVCmax). %CVCmax in the COX-inhibited site remained greater than the control site with ΔTor ≤ 0.3°C; however, there was no difference between these sites with ΔTor ≥ 0.4°C. NOS inhibition and combined COX and NOS inhibition attenuated reflex vasodilation compared with control (P < 0.001), but there was no difference between these sites. Localized COX inhibition with ketorolac significantly augments baseline CVC but does not alter the subsequent skin blood flow response to hyperthermia, suggesting a limited role for COX-derived vasodilator prostanoids in reflex cutaneous vasodilation and a shift toward COX-derived vasoconstrictors in middle-aged human skin. PMID:19661446
Sprung, V S; Cuthbertson, D J; Pugh, C J A; Daousi, C; Atkinson, G; Aziz, N F; Kemp, G J; Green, D J; Cable, N T; Jones, H
2013-01-01
Polycystic ovary syndrome (PCOS) is associated with cardiovascular disease. The contribution of the nitric oxide (NO) dilator system to cutaneous endothelial dysfunction is currently unknown in PCOS. Our aim was to examine whether women with PCOS demonstrate impaired cutaneous microvascular NO function and whether exercise training can ameliorate any impairment. Eleven women with PCOS (age, 29 ± 7 years; body mass index, 34 ± 6 kg m−2) were compared with six healthy obese control women (age, 29 ± 7 years; body mass index, 34 ± 5 kg m−2). Six women with PCOS (30 ± 7 years; 31 ± 6 kg m−2) then completed 16 weeks of exercise training. Laser Doppler flowmetry, combined with intradermal microdialysis of l-NG-monomethyl-l-arginine, a nitric oxide antagonist, in response to incremental local heating of the forearm was assessed in women with PCOS and control women, and again in women with PCOS following exercise training. Cardiorespiratory fitness, homeostasis model assessment for insulin resistance, hormone and lipid profiles were also assessed. Differences between women with PCOS and control women and changes with exercise were analysed using Student's unpaired t tests. Differences in the contribution of NO to cutaneous blood flow [expressed as a percentage of maximal cutaneous vasodilatation (CVCmax)] were analysed using general linear models. At 42°C heating, cutaneous NO-mediated vasodilatation was attenuated by 17.5%CVCmax (95% confidence interval, 33.3, 1.7; P = 0.03) in women with PCOS vs. control women. Exercise training improved cardiorespiratory fitness by 5.0 ml kg−1 min−1 (95% confidence interval, 0.9, 9.2; P = 0.03) and NO-mediated cutaneous vasodilatation at 42°C heating by 19.6% CVCmax (95% confidence interval, 4.3, 34.9; P = 0.02). Cutaneous microvascular NO function is impaired in women with PCOS compared with obese matched control women but can be improved with exercise training. PMID:23318877
Asberg, A; Midtvedt, K; Vassbotn, T; Hartmann, A
2001-07-01
The prevalence of hypertension in renal transplant recipients is high but the pathophysiology is poorly defined. Impaired endothelial function may be a factor of major importance. The present study addresses the effects of long-term treatment with either lisinopril or slow-release nifedipine on microvascular function and plasma endothelin in renal transplant recipients on cyclosporin A (CsA). Seventy-five hypertensive renal transplant recipients were double-blind randomized to receive slow-release nifedipine (NIF, n=40) or lisinopril (LIS, n=35). Ten normotensive, age-matched recipients served as controls. All patients received CsA-based immunosuppressive therapy including prednisolone and azathioprine. Microvascular function was assessed in the forearm skin vasculature, using laser Doppler flowmetry in combination with post-occlusive reactive hyperaemia and endothelial-dependent function during local acetylcholine (ACh) stimulation. The analysis of microvascular function (AUC(rh)) showed that nifedipine-treated patients had significantly lower responses compared with lisinopril-treated patients (20+/-17 and 43+/-20 AU x min respectively, P=0.0016). Endothelial function was borderline significantly lower in the NIF group compared with the LIS group (640+/-345 and 817+/-404 AU x min respectively, P=0.056). The responses in the LIS group were comparable with those in non-hypertensive controls (AUC(rh) was 37+/-16 and AUC(ACh) was 994+/-566 AU x min). Plasma endothelin-1 concentrations were significantly higher in the NIF group compared with the LIS group (0.44+/-0.19 vs. 0.34+/-0.10 fmol/ml respectively, P=0.048), and were 0.29+/-0.09 fmol/ml in the control patients. AUC(ACh) was associated with plasma endothelin-1 (P=0.0053), while AUC(rh) was not (P=0.080). The study indicates that long-term treatment with lisinopril, when compared with nifedipine, yields a more beneficial effect on microvascular function in hypertensive renal transplant recipients on CsA. The beneficial microvascular effect may be mediated in part by an endothelin-1-associated effect on the endothelium.
Simulated Microgravity Increases Cutaneous Blood Flow in the Head and Leg of Humans
NASA Technical Reports Server (NTRS)
Stout, M. Shannon; Watenpaugh, Donald E.; Breit, Gregory A.; Hargens, Alan R.
1995-01-01
The cutaneous micro-circulation vasodilates during acute 6 deg. head-down tilt (HDT, simulated microgravity) relative to upright conditions, more in the lower body than in the upper body. We expected that relative magnitudes of and differences between upper and lower body cutaneous blood flow elevation would be sustained during initial acclimation to simulated microgravity. We measured cutaneous micro-vascular blood flow with laser-Doppler flowmetry at the leg (over the distal tibia) and cheek (over the zygomatic arch) of eight healthy men before, during, and after 24 h of HDT. Results were calculated as a percentage of baseline value (100% measured during pre-tilt upright sitting). Cutaneous blood flow in the cheek increased significantly to 165 +/- 37% (mean + SE, p less than 0.05) at 9-12 h HDT, then returned to near baseline values by 24 h HDT (114 +/- 29%, NSD), despite increased local arterial pressure. Microvascular flow in the leg remained significantly elevated above baseline throughout 24 h HDT (427 +/- 85% at 3 h HDT and 215 +/- 142% at 24 h HDT, p less than 0.05). During the 6-h upright sitting recovery period, cheek and leg blood flow levels returned to near pre-tilt baseline values. Because hydrostatic effects of HDT increase local arterial pressure at the carotid sinus, baroreflex-mediated withdrawal of sympathetic tone probably contributed to increased microvascular flows at the head and leg during HDT. In the leg, baroreflex effects combined with minimal stimulation of local veno-arteriolar and myogenic autoregulatory vasoconstriction to elicit relatively larger and more sustained increases in cutaneous flow during HDT. In the cheek, delayed myogenic vasoconstriction and/or humoral effects apparently compensated for flow elevation by 24 h of HDT. Therefore, localized vascular adaptations to gravity probably explain differences in acclimation of lower and upper body blood flow to HDT and actual microgravity.
Attenuated noradrenergic sensitivity during local cooling in aged human skin
Thompson, Caitlin S; Holowatz, Lacy A; Kenney, W. Larry
2005-01-01
Reflex-mediated cutaneous vasoconstriction (VC) is impaired in older humans; however, it is unclear whether this blunted VC also occurs during local cooling, which mediates VC through different mechanisms. We tested the hypothesis that the sensitization of cutaneous vessels to noradrenaline (NA) during direct skin cooling seen in young skin is blunted in aged skin. In 11 young (18–30 years) and 11 older (62–76 years) men and women, skin blood flow was monitored at two forearm sites with laser Doppler (LD) flowmetry while local skin temperature was cooled and clamped at 24°C. Cutaneous vascular conductance (CVC; LD flux/mean arterial pressure) was expressed as percentage change from baseline (%ΔCVCbase). At one site, five doses of NA (10−10–10−2m) were sequentially infused via intradermal microdialysis during cooling while the other 24°C site served as control (Ringer solution + cooling). At control sites, VC due to cooling alone was similar in young versus older (−54 ± 5 versus −56 ± 3%ΔCVCbase, P= 0.46). In young, NA infusions induced additional dose-dependent VC (10−8, 10−6, 10−4 and 10−2m: −70 ± 2, −72 ± 3, −78 ± 3 and −79 ± 4%ΔCVCbase; P < 0.05 versus control). In older subjects, further VC did not occur until the highest infused dose of NA (10−2m: −70 ± 5%ΔCVCbase; P < 0.05 versus control). When cutaneous arterioles are sensitized to NA by direct cooling, young skin exhibits the capacity to further constrict to NA in a dose-dependent manner. However, older skin does not display enhanced VC capacity until treated with saturating doses of NA, possibly due to age-associated decrements in Ca2+ availability or α2C-adrenoceptor function. PMID:15705648
Aoki, Ken; Zhao, Kun; Yamazaki, Fumio; Sone, Ryoko; Alvarez, Guy E; Kosiba, Wojciech A; Johnson, John M
2008-03-01
Humans and other diurnal species experience a fall in internal temperature (T(int)) at night, accompanied by increased melatonin and altered thermoregulatory control of skin blood flow (SkBF). Also, exogenous melatonin induces a fall in T(int), an increase in distal skin temperatures and altered control of the cutaneous active vasodilator system, suggesting an effect of melatonin on the control of SkBF. To test whether exogenous melatonin also affects the more tonically active vasoconstrictor system in glabrous and nonglabrous skin during cooling, healthy males (n = 9) underwent afternoon sessions of whole body skin temperature (T(sk)) cooling (water-perfused suits) after oral melatonin (Mel; 3 mg) or placebo (Cont). Cutaneous vascular conductance (CVC) was calculated from SkBF (laser Doppler flowmetry) and non-invasive blood pressure. Baseline T(int) was lower in Mel than in Cont (P < 0.01). During progressive reduction of T(sk) from 35 degrees C to 32 degrees C, forearm CVC was first significantly reduced at T(sk) of 34.33 +/- 0.01 degrees C (P < 0.05) in Cont. In contrast, CVC in Mel was not significantly reduced until T(sk) reached 33.33 +/- 0.01 degrees C (P < 0.01). The decrease in forearm CVC in Mel was significantly less than in Cont at T(sk) of 32.66 +/- 0.01 degrees C and lower (P < 0.05). In Mel, palmar CVC was significantly higher than in Cont above T(sk) of 33.33 +/- 0.01 degrees C, but not below. Thus exogenous melatonin blunts reflex vasoconstriction in nonglabrous skin and shifts vasoconstrictor system control to lower T(int). It provokes vasodilation in glabrous skin but does not suppress the sensitivity to falling T(sk). These findings suggest that by affecting the vasoconstrictor system, melatonin has a causal role in the nocturnal changes in body temperature and its control.
Jennings, John D.; Holowatz, Lacy A.; Kenney, W. Larry
2009-01-01
Primary human aging may be associated with augmented Rho kinase (ROCK)-mediated contraction of vascular smooth muscle and ROCK-mediated inhibition of nitric oxide synthase (NOS). We hypothesized that the contribution of ROCK to reflex vasoconstriction (VC) is greater in aged skin. Cutaneous VC was elicited by 1) whole body cooling [mean skin temperature (Tsk) = 30.5°C] and 2) local norepinephrine (NE) infusion (1 × 10−6 M). Four microdialysis fibers were placed in the forearm skin of eight young (Y) and eight older (O) subjects for infusion of 1) Ringer solution (control), 2) 3 mM fasudil (ROCK inhibition), 3) 20 mM NG-nitro-l-arginine methyl ester (NOS inhibition), and 4) both ROCK + NOS inhibitors. Red cell flux was measured by laser-Doppler flowmetry over each site. Cutaneous vascular conductance (CVC) was calculated as flux/mean arterial pressure and normalized to baseline CVC (%ΔCVCbaseline). VC was reduced at the control site in O during cooling (Y, −34 ± 3; and O, −18 ± 3%ΔCVCbaseline; P < 0.001) and NE infusion (Y, −53 ± 4, and O, −41 ± 9%ΔCVCbaseline; P = 0.006). Fasudil attenuated VC in both age groups during mild cooling; however, this reduction remained only in O but not in Y skin during moderate cooling (Y, −30 ± 5; and O, −7 ± 1%ΔCVCbaseline; P = 0.016) and was not altered by NOS inhibition. Fasudil blunted NE-mediated VC in both age groups (Y, −23 ± 4; and O, −7 ± 3%ΔCVCbaseline; P < 0.01). Cumulatively, these data indicate that reflex VC is more reliant on ROCK in aged skin such that approximately half of the total VC response to whole body cooling is ROCK dependent. PMID:19717729
VIP/PACAP receptor mediation of cutaneous active vasodilation during heat stress in humans.
Kellogg, Dean L; Zhao, Joan L; Wu, Yubo; Johnson, John M
2010-07-01
Vasoactive intestinal peptide (VIP) is implicated in cutaneous active vasodilation in humans. VIP and the closely related pituitary adenylate cyclase activating peptide (PACAP) act through several receptor types: VIP through VPAC1 and VPAC2 receptors and PACAP through VPAC1, VPAC2, and PAC1 receptors. We examined participation of VPAC2 and/or PAC1 receptors in cutaneous vasodilation during heat stress by testing the effects of their specific blockade with PACAP6-38. PACAP6-38 dissolved in Ringer's was administered by intradermal microdialysis at one forearm site while a control site received Ringer's solution. Skin blood flow was monitored by laser-Doppler flowmetry (LDF). Blood pressure was monitored noninvasively and cutaneous vascular conductance (CVC) calculated. A 5- to 10-min baseline period was followed by approximately 70 min of PACAP6-38 (100 microM) perfusion at one site in normothermia and a 3-min period of body cooling. Whole body heating was then performed to engage cutaneous active vasodilation and was maintained until CVC had plateaued at an elevated level at all sites for 5-10 min. Finally, 58 mM sodium nitroprusside was perfused through both microdialysis sites to effect maximal vasodilation. No CVC differences were found between control and PACAP6-38-treated sites during normothermia (19 +/- 3%max untreated vs. 20 +/- 3%max, PACAP6-38 treated; P > 0.05 between sites) or cold stress (11 +/- 2%max untreated vs. 10 +/- 2%max, PACAP6-38 treated, P > 0.05 between sites). PACAP6-38 attenuated the increase in CVC during whole body heating when compared with untreated sites (59 +/- 3%max untreated vs. 46 +/- 3%max, PACAP6-38 treated, P < 0.05). We conclude that VPAC2 and/or PAC1 receptor activation is involved in cutaneous active vasodilation in humans.
Effects of sympathetic nerve stimulation on long posterior ciliary artery blood flow in cats.
Koss, Michael C
2002-04-01
A new technique using ultrasonic flowmetry was developed in order to directly measure blood flow in the long posterior ciliary artery (LPCA) of anesthetized cats. Basal LPCA blood flow averaged about 0.6 ml/min and was stable over the experimental period. Electrical stimulation of the cervical preganglionic cervical sympathetic nerve produced frequency-dependent anterior segment ocular vasoconstrictor responses. Ipsilateral nictitating membrane contractions were simultaneously measured as a well-established index of neural sympathetic activation. LPCA frequency-response relationships were shifted to the right in comparison with those for the nictitating membrane. When elicited at two min intervals, submaximal evoked responses of both systems were stable for more than 90 min. Ocular vasoconstrictor and nictitating membrane responses were blocked in a dose-dependent fashion by intravenous treatment with the non-selective a-adrenoceptor antagonist, phentolamine (0.3-3.0 mg/kg), as well as with the selective alpha1-adrenoceptor antagonist, prazosin (3-30 microg/kg). In contrast, neither evoked response was further antagonized by subsequent administration of the alpha2-adrenoceptor antagonist, yohimbine (500 microg/kg). These results demonstrate the usefulness of ultrasonic flowmetry to study mechanisms controlling ocular anterior segment circulation and suggest that, as previously established for the nictitating membrane and anterior choroid, adrenergic neurogenic vasoconstriction in tissues perfused by the LPCA is mediated predominantly by alpha1-adrenoceptors.
Associação entre sintomas, veias varicosas e refluxo na veia safena magna ao eco-Doppler
Seidel, Amélia Cristina; Campos, Mariana Baldini; Campos, Raquel Baldini; Harada, Dérica Sayuri; Rossi, Robson Marcelo; Cavalari, Pedro; Miranda, Fausto
2017-01-01
Resumo Contexto A doença venosa crônica requer avaliação clínica, quantificação dos efeitos hemodinâmicos e definição da distribuição anatômica para decisão diagnóstica e tratamento. Métodos Estudo prospectivo realizado em 2015 com amostra de 1.384 pacientes (2.669 membros) com idade entre 17 e 85 anos, sendo 1.227 do sexo feminino. Nas respostas do questionário aplicado, os sintomas pesquisados eram dor, cansaço, sensação de peso, queimação, câimbras e formigamento. Para a formação dos grupos, foi considerado o número de membros, distribuídos em relação ao gênero, ao índice de massa corporal e à idade. Após a definição grupos e a realização do eco-Doppler para estudo da veia safena magna (VSM), os pacientes foram distribuídos em três grupos (I: sintomas presentes e varizes ausentes, II: sintomas ausentes e varizes presentes e III: sintomas presentes e varizes presentes). A análise estatística utilizou o teste qui-quadrado ou exato de Fisher para verificar a homogeneidade entre os grupos. Em caso de associação com significância de 5%, foi calculada a razão de chances. Resultados Para ambos os gêneros, foi observada chance de insuficiência da VSM 11,2 vezes maior no grupo III. Por sua vez, os casos de obesidade mórbida ocorreram 9,1 vezes mais no mesmo grupo. Além disso, pacientes na faixa etária entre 30 e 50 anos desse grupo apresentaram chance de insuficiência da VSM 43,1 vezes maior. Conclusões A insuficiência da VSM foi significantemente mais frequente no grupo III, tanto globalmente como considerando apenas os casos de obesidade mórbida e a faixa etária mais elevada. PMID:29930616
NASA Astrophysics Data System (ADS)
Yazıcı, Birsen; Son, Il-Young; Cagri Yanik, H.
2018-05-01
This paper introduces a new and novel radar interferometry based on Doppler synthetic aperture radar (Doppler-SAR) paradigm. Conventional SAR interferometry relies on wideband transmitted waveforms to obtain high range resolution. Topography of a surface is directly related to the range difference between two antennas configured at different positions. Doppler-SAR is a novel imaging modality that uses ultra-narrowband continuous waves (UNCW). It takes advantage of high resolution Doppler information provided by UNCWs to form high resolution SAR images. We introduce the theory of Doppler-SAR interferometry. We derive an interferometric phase model and develop the equations of height mapping. Unlike conventional SAR interferometry, we show that the topography of a scene is related to the difference in Doppler frequency between two antennas configured at different velocities. While the conventional SAR interferometry uses range, Doppler and Doppler due to interferometric phase in height mapping; Doppler-SAR interferometry uses Doppler, Doppler-rate and Doppler-rate due to interferometric phase in height mapping. We demonstrate our theory in numerical simulations. Doppler-SAR interferometry offers the advantages of long-range, robust, environmentally friendly operations; low-power, low-cost, lightweight systems suitable for low-payload platforms, such as micro-satellites; and passive applications using sources of opportunity transmitting UNCW.
Photoacoustic thermal flowmetry with a single light source
NASA Astrophysics Data System (ADS)
Liu, Wei; Lan, Bangxin; Hu, Leo; Chen, Ruimin; Zhou, Qifa; Yao, Junjie
2017-09-01
We report a photoacoustic thermal flowmetry based on optical-resolution photoacoustic microscopy (OR-PAM) using a single laser source for both thermal tagging and photoacoustic excitation. When an optically absorbing medium is flowing across the optical focal zone of OR-PAM, a small volume of the medium within the optical focus is repeatedly illuminated and heated by a train of laser pulses with a high repetition rate. The average temperature of the heated volume at each laser pulse is indicated by the photoacoustic signal excited by the same laser pulse due to the well-established linear relationship between the Grueneisen coefficient and the local temperature. The thermal dynamics of the heated medium volume, which are closely related to the flow speed, can therefore be measured from the time course of the detected photoacoustic signals. Here, we have developed a lumped mathematical model to describe the time course of the photoacoustic signals as a function of the medium's flow speed. We conclude that the rising time constant of the photoacoustic signals is linearly dependent on the flow speed. Thus, the flow speed can be quantified by fitting the measured photoacoustic signals using the derived mathematical model. We first performed proof-of-concept experiments using defibrinated bovine blood flowing in a plastic tube. The experiment results have demonstrated that the proposed method has high accuracy (˜±6%) and a wide range of measurable flow speeds. We further validated the method by measuring the blood flow speeds of the microvasculature in a mouse ear in vivo.
Micro-Doppler analysis of multiple frequency continuous wave radar signatures
NASA Astrophysics Data System (ADS)
Anderson, Michael G.; Rogers, Robert L.
2007-04-01
Micro-Doppler refers to Doppler scattering returns produced by non rigid-body motion. Micro-Doppler gives rise to many detailed radar image features in addition to those associated with bulk target motion. Targets of different classes (for example, humans, animals, and vehicles) produce micro-Doppler images that are often distinguishable even by nonexpert observers. Micro-Doppler features have great potential for use in automatic target classification algorithms. Although the potential benefit of using micro-Doppler in classification algorithms is high, relatively little experimental (non-synthetic) micro-Doppler data exists. Much of the existing experimental data comes from highly cooperative targets (human or vehicle targets directly approaching the radar). This research involved field data collection and analysis of micro-Doppler radar signatures from non-cooperative targets. The data was collected using a low cost Xband multiple frequency continuous wave (MFCW) radar with three transmit frequencies. The collected MFCW radar signatures contain data from humans, vehicles, and animals. The presented data includes micro-Doppler signatures previously unavailable in the literature such as crawling humans and various animal species. The animal micro-Doppler signatures include deer, dog, and goat datasets. This research focuses on the analysis of micro-Doppler from noncooperative targets approaching the radar at various angles, maneuvers, and postures.
A low cost Doppler system for vascular dialysis access surveillance.
Molina, P S C; Moraes, R; Baggio, J F R; Tognon, E A
2004-01-01
The National Kidney Foundation guidelines for vascular access recommend access surveillance to avoid morbidity among patients undergoing hemodialysis. Methods to detect access failure based on CW Doppler system are being proposed to implement surveillance programs at lower cost. This work describes a low cost Doppler system implemented in a PC notebook designed to carry out this task. A Doppler board samples the blood flow velocity and delivers demodulated quadrature Doppler signals. These signals are sampled by a notebook sound card. Software for Windows OS (running at the notebook) applies CFFT to consecutive 11.6 ms intervals of Doppler signals. The sonogram is presented on the screen in real time. The software also calculates the maximum and the intensity weighted mean frequency envelopes. Since similar systems employ DSP boards to process the Doppler signals, cost reduction was achieved. The Doppler board electronic circuits and routines to process the Doppler signals are presented.
Accuracy of three-dimensional multislice view Doppler in diagnosis of morbid adherent placenta
Abdel Moniem, Alaa M.; Ibrahim, Ahmed; Akl, Sherif A.; Aboul-Enen, Loay; Abdelazim, Ibrahim A.
2015-01-01
Objective To detect the accuracy of the three-dimensional multislice view (3D MSV) Doppler in the diagnosis of morbid adherent placenta (MAP). Material and Methods Fifty pregnant women at ≥28 weeks gestation with suspected MAP were included in this prospective study. Two dimensional (2D) trans-abdominal gray-scale ultrasound scan was performed for the subjects to confirm the gestational age, placental location, and findings suggestive of MAP, followed by the 3D power Doppler and then the 3D MSV Doppler to confirm the diagnosis of MAP. Intraoperative findings and histopathology results of removed uteri in cases managed by emergency hysterectomy were compared with preoperative sonographic findings to detect the accuracy of the 3D MSV Doppler in the diagnosis of MAP. Results The 3D MSV Doppler increased the accuracy and predictive values of the diagnostic criteria of MAP compared with the 3D power Doppler. The sensitivity and negative predictive value (NPV) (79.6% and 82.2%, respectively) of crowded vessels over the peripheral sub-placental zone to detect difficult placental separation and considerable intraoperative blood loss in cases of MAP using the 3D power Doppler was increased to 82.6% and 84%, respectively, using the 3D MSV Doppler. In addition, the sensitivity, specificity, and positive predictive value (PPV) (90.9%, 68.8%, and 47%, respectively) of the disruption of the uterine serosa-bladder interface for the detection of emergency hysterectomy in cases of MAP using the 3D power Doppler was increased to 100%, 71.8%, and 50%, respectively, using the 3D MSV Doppler. Conclusion The 3D MSV Doppler is a useful adjunctive tool to the 3D power Doppler or color Doppler to refine the diagnosis of MAP. PMID:26401104
Power Doppler evaluation of joint effusions: investigation in a rabbit model.
Strouse, P J; DiPietro, M A; Teo, E L; Doi, K; Chrisp, C E
1999-08-01
To study the power Doppler findings of septic arthritis and noninfectious synovitis in an animal model. The right knees of 10 rabbits were inoculated with an aqueous suspension of Staphylococcus aureus. The right knees of 5 rabbits were injected with talc suspension. The right knees of 5 rabbits were injected with saline. All 20 left knees were injected with saline. Serial power Doppler images were obtained using constant-imaging parameters. Images were reviewed by blinded observers who assessed for increased power Doppler signal. All 10 knees inoculated with S. aureus developed septic arthritis. Each infected rabbit knee demonstrated increased signal on power Doppler on at least one examination, ranging from 1-6 days after inoculation. Only 23 of 45 examinations of infected knees were unequivocally positive by power Doppler on examinations performed 1 to 6 days after inoculation. No knee with talc synovitis demonstrated increased power Doppler signal. No control knee demonstrated increased power Doppler signal. Increased power Doppler signal may be seen with septic arthritis; however, its intensity and timing may vary from subject to subject. A normal power Doppler examination does not exclude septic arthritis.
Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin; Ellegaard, Karen; D'Agostino, Maria Antonietta; Iagnocco, Annamaria; Naredo, Esperanza; Balint, Peter; Wakefield, Richard J; Torp-Pedersen, Arendse; Terslev, Lene
2015-02-01
To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. Six different types of ultrasound machines were used. On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. Power Doppler was more sensitive on half of the machines, whereas color Doppler was more sensitive on the other half, using both factory settings and study settings. There was an average increase in Doppler sensitivity, despite modality, of 78% when study settings were applied. Over the 6 machines, 2 Doppler modalities, and 2 settings, the grades for each of 7 of the patients varied between 0 and 3, while the grades for each of the other 4 patients varied between 0 and 2. The effect of using different machines, Doppler modalities, and settings has a considerable influence on the quantification of inflammation by ultrasound in RA patients, and this must be taken into account in multicenter studies. Copyright © 2015 by the American College of Rheumatology.
NASA Astrophysics Data System (ADS)
Ruiz, Michael J.; Abee, Jeremy
2006-10-01
In this paper we present a design for a Doppler football. The classic Doppler ball uses a piezo buzzer and 9-V battery inside a foam ball. In our Doppler football, the sound level is enhanced by directing the 2.8-kHz tone of the buzzer through a hollow cylinder to one end of the football, with an on-off switch placed at the other end. We discuss our device within the historical context of Doppler demonstrations that have evolved over the many decades since Doppler's discovery.
Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu
2017-11-01
To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Evaluation of meteorological airborne Doppler radar
NASA Technical Reports Server (NTRS)
Hildebrand, P. H.; Mueller, C. K.
1984-01-01
This paper will discuss the capabilities of airborne Doppler radar for atmospheric sciences research. The evaluation is based on airborne and ground based Doppler radar observations of convective storms. The capability of airborne Doppler radar to measure horizontal and vertical air motions is evaluated. Airborne Doppler radar is shown to be a viable tool for atmospheric sciences research.
Ghori, Ahmer K; Chung, Kevin C
2007-12-01
The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.
NASA Technical Reports Server (NTRS)
Jamora, Dennis A.
1993-01-01
Ground clutter interference is a major problem for airborne pulse Doppler radar operating at low altitudes in a look-down mode. With Doppler zero set at the aircraft ground speed, ground clutter rejection filtering is typically accomplished using a high-pass filter with real valued coefficients and a stopband notch centered at zero Doppler. Clutter spectra from the NASA Wind Shear Flight Experiments of l991-1992 show that the dominant clutter mode can be located away from zero Doppler, particularly at short ranges dominated by sidelobe returns. Use of digital notch filters with complex valued coefficients so that the stopband notch can be located at any Doppler frequency is investigated. Several clutter mode tracking algorithms are considered to estimate the Doppler frequency location of the dominant clutter mode. From the examination of night data, when a dominant clutter mode away from zero Doppler is present, complex filtering is able to significantly increase clutter rejection over use of a notch filter centered at zero Doppler.
[The application of Doppler broadening and Doppler shift to spectral analysis].
Xu, Wei; Fang, Zi-shen
2002-08-01
The distinction between Doppler broadening and Doppler shift has analyzed, Doppler broadening locally results from the distribution of velocities of the emitting particles, the line width gives the information on temperature of emitting particles. Doppler shift results when the emitting particles have a bulk non random flow velocity in a particular direction, the drift of central wavelength gives the information on flow velocity of emitting particles, and the Doppler shift only drifts the profile of line without changing the width. The difference between Gaussian fitting and the distribution of chord-integral line shape have also been discussed. The distribution of H alpha spectral line shape has been derived from the surface of limiter in HT-6M Tokamak with optical spectroscope multichannel analysis (OSMA), the result by double Gaussian fitting shows that the line shape make up of two port, the emitting of reflect particles with higher energy and the release particle from the limiter surface. Ion temperature and recycling particle flow velocity have been obtained from Doppler broadening and Doppler shift.
Analysis and prediction of Doppler noise during solar conjunctions
NASA Technical Reports Server (NTRS)
Berman, A. L.; Rockwell, S. T.
1975-01-01
The results of a study of Doppler data noise during solar conjunctions were presented. During the first half of 1975, a sizeable data base of Doppler data noise (estimates) for the Pioneer 10, Pioneer 11, and Helios 1 solar conjunctions was accumulated. To analyze this data, certain physical assumptions are made, leading to the development of a geometric parameter ("ISI") which correlates strongly with Doppler data noise under varying sun-earth-spacecraft geometries. Doppler noise models are then constructed from this parameter, resulting in the newfound ability to predict Doppler data noise during solar conjunctions, and hence to additionally be in a position to validate Doppler data acquired during solar conjunctions.
Sripathi, Smiti; Mahajan, Abhishek
2013-09-01
To analyze qualitative and quantitative parameters of lung tumors by color Doppler sonography, determine the role of color Doppler sonography in predicting chest wall invasion by lung tumors using spectral waveform analysis, and compare color Doppler sonography and computed tomography (CT) for predicting chest wall invasion by lung tumors. Between March and September 2007, 55 patients with pleuropulmonary lesions on chest radiography were assessed by grayscale and color Doppler sonography for chest wall invasion. Four patients were excluded from the study because of poor acoustic windows. Quantitative and qualitative sonographic examinations of the lesions were performed using grayscale and color Doppler imaging. The correlation between the color Doppler and CT findings was determined, and the final outcomes were correlated with the histopathologic findings. Of a total of 51 lesions, 32 were malignant. Vascularity was present on color Doppler sonography in 28 lesions, and chest wall invasion was documented in 22 cases. Computed tomography was performed in 24 of 28 evaluable malignant lesions, and the findings were correlated with the color Doppler findings for chest wall invasion. Of the 24 patients who underwent CT, 19 showed chest wall invasion. The correlation between the color Doppler and CT findings revealed that color Doppler sonography had sensitivity of 95.6% and specificity of 100% for assessing chest wall invasion, whereas CT had sensitivity of 85.7% and specificity of 66.7%. Combined qualitative and quantitative color Doppler sonography can predict chest wall invasion by lung tumors with better sensitivity and specificity than CT. Although surgery is the reference standard, color Doppler sonography is a readily available, affordable, and noninvasive in vivo diagnostic imaging modality that is complementary to CT and magnetic resonance imaging for lung cancer staging.
De Boer, M. A.; Heymans, M. W.; Schoonmade, L. J.; Bossuyt, P. M. M.; Mol, B. W. J.; De Groot, C. J. M.; Bax, C. J.
2018-01-01
ABSTRACT Objective Doppler ultrasonographic assessment of the cerebroplacental ratio (CPR) and middle cerebral artery (MCA) is widely used as an adjunct to umbilical artery (UA) Doppler to identify fetuses at risk of adverse perinatal outcome. However, reported estimates of its accuracy vary considerably. The aim of this study was to review systematically the prognostic accuracies of CPR and MCA Doppler in predicting adverse perinatal outcome, and to compare these with UA Doppler, in order to identify whether CPR and MCA Doppler evaluation are of added value to UA Doppler. Methods PubMed, EMBASE, the Cochrane Library and ClinicalTrials.gov were searched, from inception to June 2016, for studies on the prognostic accuracy of UA Doppler compared with CPR and/or MCA Doppler in the prediction of adverse perinatal outcome in women with a singleton pregnancy of any risk profile. Risk of bias and concerns about applicability were assessed using the QUADAS‐2 (Quality Assessment of Diagnostic Accuracy Studies‐2) tool. Meta‐analysis was performed for multiple adverse perinatal outcomes. Using hierarchal summary receiver–operating characteristics meta‐regression models, the prognostic accuracy of CPR vs MCA Doppler was compared indirectly, and CPR and MCA Doppler vs UA Doppler compared directly. Results The search identified 4693 articles, of which 128 studies (involving 47 748 women) were included. Risk of bias or suboptimal reporting was detected in 120/128 studies (94%) and substantial heterogeneity was found, which limited subgroup analyses for fetal growth and gestational age. A large variation was observed in reported sensitivities and specificities, and in thresholds used. CPR outperformed UA Doppler in the prediction of composite adverse outcome (as defined in the included studies) (P < 0.001) and emergency delivery for fetal distress (P = 0.003), but was comparable to UA Doppler for the other outcomes. MCA Doppler performed significantly worse than did UA Doppler in the prediction of low Apgar score (P = 0.017) and emergency delivery for fetal distress (P = 0.034). CPR outperformed MCA Doppler in the prediction of composite adverse outcome (P < 0.001) and emergency delivery for fetal distress (P = 0.013). Conclusion Calculating the CPR with MCA Doppler can add value to UA Doppler assessment in the prediction of adverse perinatal outcome in women with a singleton pregnancy. However, it is unclear to which subgroup of pregnant women this applies. The effectiveness of the CPR in guiding clinical management needs to be evaluated in clinical trials. © 2017 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology. PMID:28708272
Eventos de Desconexao na Cauda de Plasma do Cometa P/Halley
NASA Astrophysics Data System (ADS)
Voelzke, M. R.; Fahr, H. J.
2001-08-01
Observacoes cometárias e de vento solar sao comparadas com o propósito de determinar-se as condicoes do vento solar associadas aos eventos de desconexao (DEs) observados em caudas de plasma cometárias. Os dados cometários sao provenientes do The International Halley Watch Atlas of Large-Scale Phenomena. A análise visual sistemática das imagens do atlas revelou, entre outras estruturas morfológicas, 47 DEs ao longo da cauda de plasma do P/Halley. Estes 47 DEs registrados em 47 imagens distintas permitiram a descoberta de 19 origens de DEs, ou seja, o tempo em que as desconexoes iniciaram foi calculado. Os dados do vento solar sao provenientes de medidas feitas in situ pela sonda espacial IMP-8, as quais foram usadas para elaborar a variacao da velocidade do vento solar, densidade e pressao dinâmica durante o intervalo analisado. O presente trabalho compara as atuais teorias conflitantes, baseadas nos mecanismos de formacao, com o intuito de explicar o fenômeno cíclico dos DEs, ou seja, os efeitos de producao iônica, os efeitos de pressao e os efeitos de reconexao magnética sao analisados. Para cada uma das 19 origens de DEs comparou-se a densidade com a respectiva velocidade do vento solar com o intuito de determinar-se uma possível correlacao entre estas origens e os efeitos de pressao dinâmica. Quando da ocorrência de 6 origens de DEs o IMP-8 nao realizou medidas, nos outros 13 casos 10 origens (77%) mostraram uma anticorrelacao entre velocidade e densidade e apenas 3 (23%) revelaram uma tendência similar entre velocidade e densidade. Portanto, a análise inicial demonstra uma fraca correlacao entre as origens dos DEs e os efeitos de pressao.
Analysis of blood flow in the long posterior ciliary artery of the cat.
Koss, M C
1999-03-01
Experiments were undertaken to use a new technique for direct on-line measurement of blood flow in the long posterior ciliary artery (LPCA) in cats and to evaluate possible physiological mechanisms controlling blood flow in the vascular beds perfused by this artery. Blood flow in the temporal LPCA was measured on a continuous basis using ultrasonic flowmetry in anesthetized cats. Effects of acute sectioning of the sympathetic nerve and changes in LPCA and cerebral blood flows in response to altered levels of inspired CO2 and O2 were tested in some animals. In others, the presence of vascular autoregulatory mechanisms in response to stepwise elevations of intraocular pressure was studied. Blood flow in the temporal LPCA averaged 0.58+/-0.03 ml/min in 45 cats anesthetized with pentobarbital. Basal LPCA blood flow was not altered by acute sectioning of the sympathetic nerve or by changes in low levels of inspired CO2 and O2, although 10% CO2 caused a modest increase. Stepwise elevations of intraocular pressure resulted in comparable stepwise decreases of LPCA blood flow, with perfusion pressure declining in a linear manner throughout the perfusion-pressure range. Ultrasonic flowmetry seems to be a useful tool for continuous on-line measurement of LPCA blood flow in the cat eye. Blood flow to vascular beds perfused by this artery does not seem to be under sympathetic neural control and is refractory to modest alterations of blood gas levels of CO2 and O2. Blood vessels perfused by the LPCA show no clear autoregulatory mechanisms.
Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?
Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V
2015-12-01
Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.
New Doppler echocardiographic applications for the study of diastolic function
NASA Technical Reports Server (NTRS)
Garcia, M. J.; Thomas, J. D.; Klein, A. L.
1998-01-01
Doppler echocardiography is one of the most useful clinical tools for the assessment of left ventricular (LV) diastolic function. Doppler indices of LV filling and pulmonary venous (PV) flow are used not only for diagnostic purposes but also for establishing prognosis and evaluating the effect of therapeutic interventions. The utility of these indices is limited, however, by the confounding effects of different physiologic variables such as LV relaxation, compliance and filling pressure. Since alterations in these variables result in changes in Doppler indices of opposite direction, it is often difficult to determine the status of a given variable when a specific Doppler filling pattern is observed. Recently, color M-mode and tissue Doppler have provided useful insights in the study of diastolic function. These new Doppler applications have been shown to provide an accurate estimate of LV relaxation and appear to be relatively insensitive to the effects of preload compensation. This review will focus on the complementary role of color M-mode and tissue Doppler echocardiography and traditional Doppler indices of LV filling and PV flow in the assessment of diastolic function.
Use of global ionospheric maps for HF Doppler measurements interpretation
NASA Astrophysics Data System (ADS)
Petrova, I. R.; Bochkarev, V. V.; Latypov, R. R.
2018-04-01
The HF Doppler technique, a method of measurement of Doppler frequency shift of ionospheric signal, is one of the well-known and widely used techniques of ionosphere research. It allows investigation of various disturbances in the ionosphere. There are different sources of disturbances in the ionosphere such as geomagnetic storms, solar flashes, meteorological effects and atmospheric waves. The HF Doppler technique allows us to find out the influence of earthquakes, explosions and other processes on the ionosphere, which occurs near the Earth. HF Doppler technique has high sensitivity to small frequency variations and high time resolution but interpretation of results is difficult. In this paper, we attempt to use GPS data for Doppler measurements interpretation. Modeling of Doppler frequency shift variations with use of TEC allows separation of ionosphere disturbances of medium scale.
Effects of saxagliptin on early microvascular changes in patients with type 2 diabetes.
Ott, Christian; Raff, Ulrike; Schmidt, Stephanie; Kistner, Iris; Friedrich, Stefanie; Bramlage, Peter; Harazny, Joanna M; Schmieder, Roland E
2014-01-14
Patients with diabetes mellitus are at increased risk for microvascular complications. Early changes in microcirculation are characterized by hyperperfusion (e.g. in the retina and kidney) and increased pulse wave reflection leading to increased aortic pressure. We investigated the effects of the DPP-4-inhibitor saxagliptin on early retinal microvascular changes. In this double-blind, controlled, cross-over trial 50 patients (without clinical signs of microvascular alterations) with type-2 diabetes (mean duration of 4 years) were randomized to receive placebo or 5 mg saxagliptin for 6 weeks. Retinal arteriolar structure and retinal capillary flow (RCF) at baseline and during flicker-light exposure was assessed by scanning laser Doppler flowmetry. Central hemodynamics were assessed by pulse wave analysis. Postprandial blood glucose (9.27 ± 0.4 versus 10.1 ± 0.4 mmol/L; p = 0.001) and HbA1c (6.84 ± 0.15 (51 ± 1.6) versus 7.10 ± 0.17% (54 ± 1.9 mmol/mol); p < 0.001) were significantly reduced with saxagliptin treatment compared to placebo. RCF was significantly reduced after treatment with saxagliptin (288 ± 13.2 versus 314 ± 14.1 AU; p = 0.033). This was most pronounced in a subgroup of patients (n = 32) with a fall in postprandial blood glucose (280 ± 12.1 versus 314 ± 16.6 AU; p = 0.011). No significant changes in RCF were seen during flicker-light exposure between placebo and saxagliptin, but the vasodilatory capacity increased two-fold with saxagliptin treatment. Central augmentation pressure tended to be lower after treatment with saxagliptin (p = 0.094), and central systolic blood pressure was significantly reduced (119 ± 2.3 versus 124 ± 2.3 mmHg; p = 0.038). Our data suggest that treatment with saxagliptin for 6 weeks normalizes retinal capillary flow and improves central hemodynamics in type-2 diabetes. The study was registered at (ID: NCT01319357).
Silva, Henrique; Ferreira, Hugo; Bujan, Ma Julia; Rodrigues, Luis Monteiro
2015-05-01
The human skin is an interesting model to explore microcirculation, particularly if using noninvasive technologies such as LDF (Laser Doppler Flowmetry) and tc (transcutaneous) gasimetry and methods as near as possible from the normal physiological state. In this study, we combined those technologies with three classical approaches--leg raising from supine, suprasystolic occlusion (in the ankle), and normobaric oxygen breathing to explore distal peripheral circulation in the foot. These methods are often cited, but a comparative assessment has not been done. The goal of this study was to identify relevant flow related descriptors, method-related advantages and pitfalls, and eventually, to find the best experimental approach. Volunteers (both genders, 22.1 ± 3.7 years old) were subjected to these methods and variables registered during basal, challenge and stabilization phases. Descriptive and comparative statistics were obtained, adopting a 95% confidence level. All flow-related quantitative descriptors potentially useful for the analysis were identified and compared. As expected, male patients consistently showed higher LDF levels and transepidermal water loss (TEWL) and lower tcpO2 values. However, lower results were recorded in the supine position, suggesting a postural dependence. Both leg raising and suprasystolic occlusion produced a hyperemic response after provocation, although different in magnitude, significantly reducing LDF and tcpO2 during provocation. The oxygen breathing method provided the most patient-friendly protocol, consistently reducing LDF (potentially by the inhibition of production of local vasodilators). TEWL increased during the provocation phase in all protocols, although not significantly. Baseline tcpO2 was found to correlate positively with the peak tcpO2 during oxygen breathing and basal LDF with peak flow during leg raising and suprasystolic occlusion. No statistical correlation between TEWL and LDF could be demonstrated under the current experimental conditions. We conclude that although equally useful considering the purpose, these methods involve very different practicalities and do not provide the same information. Also noteworthy, LDF is a highly sensitive indicator that could be further explored to look deeper into blood flow regulating mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.
Effect of whole-body and local heating on cutaneous vasoconstrictor responses in humans
NASA Technical Reports Server (NTRS)
Wilson, Thad E.; Cui, Jian; Crandall, Craig G.
2002-01-01
Animal studies suggest that alpha-adrenergic-mediated vasoconstriction is compromised during whole-body heating. The purpose of this study was to identify whether whole-body heating and/or local surface heating reduce cutaneous alpha-adrenergic vasoconstrictor responsiveness in human skin. Protocol I: Six subjects were exposed to neutral skin temperature (i.e., 34 degrees C), whole-body heating, and local heating of forearm skin to increase skin blood flow to the same relative magnitude as that observed during whole-body heating. Protocol II: In eight subjects forearm skin was locally heated to 34, 37, 40, and 42 degrees C. During both protocols, alpha-adrenergic vasoconstrictor responsiveness was assessed by local delivery of norepinephrine (NE) via intradermal microdialysis. Skin blood flow was continuously monitored over each microdialysis membrane via laser-Doppler flowmetry. In protocol I, whole-body and local heating caused similar increases in cutaneous vascular conductance (CVC). The EC50 (log NE dose) of the dose-response curves for both whole body (-4.2 +/- 0.1 M) and local heating (-4.7 +/- 0.4 M) were significantly greater (i.e., high dose required to cause 50% reduction in CVC) relative to neutral skin temperature (- 5.6 +/- 0.0 M; P<0.05 for both). In both local and whole-body heated conditions CVC did not return to pre-heating values even at the highest dose of NE. In protocol II, calculated EC50 for 34, 37, 40, and 42 degrees C local heating was - 5.5 +/- 0.4, -4.6 +/- 0.3, -4.5 +/- 0.3, - 4.2 +/- 0.4 M, respectively. Statistical analyses revealed that the EC50 for 37,40 and 42 degrees C were significantly greater than the EC50 for 34 degrees C. These results indicate that even during administration of high concentrations of NE, alpha-adrenergic vasoconstriction does not fully compensate for local heating and whole-body heating induced vasodilatation in young, healthy subjects. Moreover, these data suggest that elevated local temperatures, above 37 degrees C, and whole-body heating similarly attenuate cutaneous alpha-adrenergic vasoconstriction responsiveness.
De Ciuceis, Carolina; Agabiti Rosei, Claudia; Caletti, Stefano; Trapletti, Valentina; Coschignano, Maria A; Tiberio, Guido A M; Duse, Sarah; Docchio, Franco; Pasinetti, Simone; Zambonardi, Federica; Semeraro, Francesco; Porteri, Enzo; Solaini, Leonardo; Sansoni, Giovanna; Pileri, Paola; Rossini, Claudia; Mittempergher, Francesco; Portolani, Nazario; Ministrini, Silvia; Agabiti-Rosei, Enrico; Rizzoni, Damiano
2018-05-01
The evaluation of the morphological characteristics of small resistance arteries in humans is challenging. The gold standard method is generally considered to be the measurement by wire or pressure micromyography of the media-to-lumen ratio of subcutaneous small vessels obtained by local biopsies. However, noninvasive techniques for the evaluation of retinal arterioles were recently proposed; in particular, two approaches, scanning laser Doppler flowmetry (SLDF) and adaptive optics, seem to provide useful information; both of them provide an estimation of the wall-to-lumen ratio (WLR) of retinal arterioles. Moreover, a noninvasive measurement of basal and total capillary density may be obtained by videomicroscopy/capillaroscopy. No direct comparison of these three noninvasive techniques in the same population was previously performed; in particular, adaptive optics was never validated against micromyography. In the current study, we enrolled 41 controls and patients: 12 normotensive lean controls, 12 essential hypertensive lean patients, nine normotensive obese patients and eight hypertensive obese patients undergoing elective surgery. All patients underwent a biopsy of subcutaneous fat during surgery. Subcutaneous small resistance artery structure was assessed by wire micromyography and the media-to-lumen ratio was calculated. WLR of retinal arterioles was obtained by SLDF and adaptive optics. Functional (basal) and structural (total) microvascular density was evaluated by capillaroscopy before and after venous congestion. Our data suggest that adaptive optics has a substantial advantage over SLDF in terms of evaluation of microvascular morphology, as WLR measured with adaptive optics is more closely correlated with the M/L of subcutaneous small arteries (r = 0.84, P < 0.001 vs. r = 0.52, P < 0.05, slopes of the relations: P < 0.01 adaptive optics vs. SLDF). In addition, the reproducibility of the evaluation of the WLR with adaptive optics is far better, as compared with SLDF, as intraobserver and interobserver variation coefficients are clearly smaller. This may be important in terms of clinical evaluation of microvascular morphology in a clinical setting, as micromyography has substantial limitations in its clinical application due to the local invasiveness of the procedure.
Bergstrand, S; Källman, U; Ek, A-C; Engström, M; Lindgren, M
2015-08-01
The aim of this study was to explore the interaction between interface pressure, pressure-induced vasodilation, and reactive hyperaemia with different pressure-redistribution mattresses. A cross-sectional study was performed with a convenience sample of healthy young individuals, and healthy older individuals and inpatients, at a university hospital in Sweden. Blood flow was measured at depths of 1mm, 2mm, and 10mm using laser Doppler flowmetry and photoplethysmography. The blood flow, interface pressure and skin temperature were measured in the sacral tissue before, during, and after load while lying on one standard hospital mattress and three different pressure-redistribution mattresses. There were significant differences between the average sacral pressure, peak sacral pressure, and local probe pressure on the three pressure-redistribution mattresses, the lowest values found were with the visco-elastic foam/air mattress (23.5 ± 2.5mmHg, 49.3 ± 11.1mmHg, 29.2 ± 14.0mmHg, respectively). Blood flow, measured as pressure-induced vasodilation, was most affected in the visco-elastic foam/air group compared to the alternating pressure mattress group at tissue depths of 2mm (39.0% and 20.0%, respectively), and 10mm (56.9 % and 35.1%, respectively). Subjects in all three groups, including healthy 18-65 year olds, were identified with no pressure-induced vasodilation or reactive hyperaemia on any mattress (n=11), which is considered a high-risk blood flow response. Interface pressure magnitudes considered not harmful during pressure-exposure on different pressure-redistribution mattresses can affect the microcirculation in different tissue structures. Despite having the lowest pressure values compared with the other mattresses, the visco-elastic foam/air mattress had the highest proportion of subjects with decreased blood flow. Healthy young individuals were identified with the high-risk blood flow response, suggesting an innate vulnerability to pressure exposure. Furthermore, the evaluation of pressure-redistribution support surfaces in terms of mean blood flow during and after tissue exposure is not feasible, but assessment of pressure-induced vasodilation and reactive hyperaemia could be a new way to assess individualised physiological measurements of mechanisms known to be related to pressure ulcer development.
Relationship between skin blood flow and sweating rate, and age related regional differences.
Inoue, Y; Shibasaki, M; Hirata, K; Araki, T
1998-12-01
To examine the mechanisms and regional differences in the age-related decrement of skin blood flow, 11 young (age 20-25 years) and 10 older (age 64-76 years) men were exposed to a mild heat stress by immersing their feet and lower legs in water at 42 degrees C for 60 min, while they were sitting in near thermoneutral conditions [25 degrees C and 45% relative humidity (rh)]. During the equilibrium period (25 degrees C and 45% rh) before the heat test, no group differences were observed in rectal (Tre) and mean skin (Tsk) temperatures or mean arterial pressure (MAP). During passive heating, Tsk was significantly lower in the older men 20 min after commencing exposure (P<0.001), although there were similar increases in Tre in both groups. Exposure time and age did not affect MAP. The local sweating rate (m(sw)) and the percentage change in skin blood flow by laser Doppler flowmetry (%LDF) relative to baseline values on the chest, back, forearm and thigh were significantly lower in the older men (P<0.001), especially on the thigh. After starting the heat exposure, three temporal phases were observed in the relationship between %LDF and m(sw) at most sites in each subject. In phase A, %LDF increased but with no increase in m(sw). In phase B, m(sw) increased but with no secondary increase in %LDF. Finally, in phase C, there were proportional increases in %LDF and m(sw). The increase in %LDF in phase A was significantly lower on the forearm and thigh (P<0.05) for the older men, but not on the chest and back. In phase C, the slopes of the regression lines between %LDF and m(sw) were lower for the older men on the back (P<0.03), forearm (P = 0.08) and thigh (P<0.03), but not on the chest. These results would suggest that the age-related decrement in skin blood flow in response to passive heating may be due in part to a smaller release of vasoconstrictor tone and to less active vasodilatation once sweating begins. Regional differences exist in the impaired vasoconstriction and active vasodilatation systems.
Garbaisz, David; Turoczi, Zsolt; Aranyi, Peter; Fulop, Andras; Rosero, Oliver; Hermesz, Edit; Ferencz, Agnes; Lotz, Gabor; Harsanyi, Laszlo; Szijarto, Attila
2014-01-01
Introduction Operation on the infrarenal aorta and large arteries of the lower extremities may cause rhabdomyolysis of the skeletal muscle, which in turn may induce remote kidney injury. NIM-811 (N-metyl-4-isoleucine-cyclosporine) is a mitochondria specific drug, which can prevent ischemic-reperfusion (IR) injury, by inhibiting mitochondrial permeability transition pores (mPTP). Objectives Our aim was to reduce damages in the skeletal muscle and the kidney after IR of the lower limb with NIM-811. Materials and methods Wistar rats underwent 180 minutes of bilateral lower limb ischemia and 240 minutes of reperfusion. Four animal groups were formed called Sham (receiving vehicle and sham surgery), NIM-Sham (receiving NIM-811 and sham surgery), IR (receiving vehicle and surgery), and NIM-IR (receiving NIM-811 and surgery). Serum, urine and histological samples were taken at the end of reperfusion. NADH-tetrazolium staining, muscle Wet/Dry (W/D) ratio calculations, laser Doppler-flowmetry (LDF) and mean arterial pressure (MAP) monitoring were performed. Renal peroxynitrite concentration, serum TNF-α and IL-6 levels were measured. Results Less significant histopathological changes were observable in the NIM-IR group as compared with the IR group. Serum K+ and necroenzyme levels were significantly lower in the NIM-IR group than in the IR group (LDH: p<0.001; CK: p<0.001; K+: p = 0.017). Muscle mitochondrial viability proved to be significantly higher (p = 0.001) and renal function parameters were significantly better (creatinine: p = 0.016; FENa: p<0.001) in the NIM-IR group in comparison to the IR group. Serum TNF-α and IL-6 levels were significantly lower (TNF-α: p = 0.003, IL-6: p = 0.040) as well as W/D ratio and peroxynitrite concentration were significantly lower (p = 0.014; p<0.001) in the NIM-IR group than in the IR group. Conclusion NIM-811 could have the potential of reducing rhabdomyolysis and impairment of the kidney after lower limb IR injury. PMID:24968303
Garbaisz, David; Turoczi, Zsolt; Aranyi, Peter; Fulop, Andras; Rosero, Oliver; Hermesz, Edit; Ferencz, Agnes; Lotz, Gabor; Harsanyi, Laszlo; Szijarto, Attila
2014-01-01
Operation on the infrarenal aorta and large arteries of the lower extremities may cause rhabdomyolysis of the skeletal muscle, which in turn may induce remote kidney injury. NIM-811 (N-metyl-4-isoleucine-cyclosporine) is a mitochondria specific drug, which can prevent ischemic-reperfusion (IR) injury, by inhibiting mitochondrial permeability transition pores (mPTP). Our aim was to reduce damages in the skeletal muscle and the kidney after IR of the lower limb with NIM-811. Wistar rats underwent 180 minutes of bilateral lower limb ischemia and 240 minutes of reperfusion. Four animal groups were formed called Sham (receiving vehicle and sham surgery), NIM-Sham (receiving NIM-811 and sham surgery), IR (receiving vehicle and surgery), and NIM-IR (receiving NIM-811 and surgery). Serum, urine and histological samples were taken at the end of reperfusion. NADH-tetrazolium staining, muscle Wet/Dry (W/D) ratio calculations, laser Doppler-flowmetry (LDF) and mean arterial pressure (MAP) monitoring were performed. Renal peroxynitrite concentration, serum TNF-α and IL-6 levels were measured. Less significant histopathological changes were observable in the NIM-IR group as compared with the IR group. Serum K+ and necroenzyme levels were significantly lower in the NIM-IR group than in the IR group (LDH: p<0.001; CK: p<0.001; K+: p = 0.017). Muscle mitochondrial viability proved to be significantly higher (p = 0.001) and renal function parameters were significantly better (creatinine: p = 0.016; FENa: p<0.001) in the NIM-IR group in comparison to the IR group. Serum TNF-α and IL-6 levels were significantly lower (TNF-α: p = 0.003, IL-6: p = 0.040) as well as W/D ratio and peroxynitrite concentration were significantly lower (p = 0.014; p<0.001) in the NIM-IR group than in the IR group. NIM-811 could have the potential of reducing rhabdomyolysis and impairment of the kidney after lower limb IR injury.
Oral vitamin C enhances the adrenergic vasoconstrictor response to local cooling in human skin.
Yamazaki, Fumio
2012-05-01
Local administration of ascorbic acid (Asc) at a supraphysiological concentration inhibits the cutaneous vasoconstrictor response to local cooling (LC). However, whether orally ingesting Asc inhibits the LC-induced vasoconstrictor response remains unknown. The purpose of the present study was to examine the acute influence of oral Asc on the adrenergic vasoconstrictor response to LC in human skin. In experiment 1, skin blood flow (SkBF) was measured by laser-Doppler flowmetry at three sites (forearm, calf, palm). The three skin sites were locally cooled from 34 to 24°C at -1°C/min and maintained at 24°C for 20 min before (Pre) and 1.5 h after (Post) oral Asc (2-g single dose) or placebo supplementation. Cutaneous vascular conductance (CVC) was calculated as the ratio of SkBF to blood pressure and expressed relative to the baseline value before LC. Oral Asc enhanced (P < 0.05) the reductions in CVC in the forearm (Pre, -50.3 ± 3.3%; Post, -57.8 ± 2.2%), calf (Pre, -52.6 ± 3.7%; Post, -66.1 ± 4.3%), and palm (Pre, -46.2 ± 6.2%; Post, -60.4 ± 5.6%) during LC. The placebo did not change the responses at any site. In experiment 2, to examine whether the increased vasoconstrictor response caused by oral Asc is due to the adrenergic system, the release of neurotransmitters from adrenergic nerves in forearm skin was blocked locally by iontophoresis of bretylium tosylate (BT). Oral Asc enhanced (P < 0.05) the reductions in CVC at untreated control sites but did not change the responses at BT-treated sites during LC. In experiment 3, to further examine whether adrenergically mediated vasoconstriction is enhanced by oral Asc, 0.1 mM tyramine was administered using intradermal microdialysis in the forearm skin at 34°C in the Pre and Post periods. Oral Asc increased (P < 0.05) the tyramine-induced reduction in CVC. These findings suggest that oral Asc acutely enhances the cutaneous vasoconstrictor responses to LC through the modification of adrenergic sympathetic mechanisms.
Stanhewicz, Anna E; Greaney, Jody L; Alexander, Lacy M; Kenney, W Larry
2017-05-01
During heat stress, blunted increases in skin sympathetic nervous system activity (SSNA) and reductions in end-organ vascular responsiveness contribute to the age-related reduction in reflex cutaneous vasodilation. In older adults, folic acid supplementation improves the cutaneous vascular conductance (CVC) response to passive heating; however, the influence of folic acid supplementation on SSNA:CVC transduction is unknown. Fourteen older adults (66 ± 1 yr, 8 male/6 female) ingested folic acid (5 mg/day) or placebo for 6 wk in a randomized, double-blind, crossover design. In protocol 1 , esophageal temperature (T es ) was increased by 1.0°C (water-perfused suit) while SSNA (peroneal microneurography) and red cell flux in the innervated dermatome (laser Doppler flowmetry; dorsum of the foot) were continuously measured. In protocol 2 , two intradermal microdialysis fibers were placed in the skin of the lateral calf for graded infusions of acetylcholine (ACh; 10 -10 to 10 -1 M) with and without nitric oxide synthase (NOS) blockade (20 mM nitro-l-arginine methyl ester). Folic acid improved reflex vasodilation (46 ± 4% vs. 31 ± 3% CVC max for placebo; P < 0.001) without affecting the increase in SSNA (Δ506 ± 104% vs. Δ415 ± 73% for placebo; NS). Folic acid increased the slope of the SSNA-to-CVC relation (0.08 ± 0.02 vs. 0.05 ± 0.01 for placebo; P < 0.05) and extended the response range. Folic acid augmented ACh-induced vasodilation (83 ± 3% vs. 66 ± 4% CVC max for placebo; P = 0.002); however, there was no difference between treatments at the NOS-inhibited site (53 ± 4% vs. 52 ± 4% CVC max for placebo; NS). These data demonstrate that folic acid supplementation enhances reflex vasodilation by increasing the sensitivity of skin arterioles to central sympathetic nerve outflow during hyperthermia in aged human subjects. Copyright © 2017 the American Physiological Society.
Klein, K U; Boehme, S; Hartmann, E K; Szczyrba, M; Heylen, L; Liu, T; David, M; Werner, C; Markstaller, K; Engelhard, K
2013-02-01
Cyclic recruitment and derecruitment (R/D) play a key role in the pathomechanism of acute lung injury (ALI) leading to respiration-dependent oscillations of arterial partial pressure of oxygen (Pa(O(2))). These Pa(O(2)) oscillations could also be forwarded to the cerebral microcirculation. In 12 pigs, partial pressure of oxygen was measured in the thoracic aorta (Pa(O(2))) and subcortical cerebral tissue (Pbr(O(2))). Cerebral cortical haemoglobin oxygen saturation (Sbr(O(2))), cerebral blood flow (CBF), and peripheral haemoglobin saturation (Sp(O(2))) were assessed by spectroscopy and laser Doppler flowmetry. Measurements at different fractions of inspired oxygen (F(I(O(2)))) were performed at baseline and during cyclic R/D. frequency domain analysis, the Mann-Whitney test, linear models to test the influence of Pa(O(2)) and systolic arterial pressure (SAP) oscillations on cerebral measurements. Parameters [mean (SD)] remained stable during baseline. Pa(O(2)) oscillations [10.6 (8) kPa, phase(reference)], systemic arterial pressure (SAP) oscillations [20 (9) mm Hg, phase(Pa(O(2))-SAP) -33 (72)°], and Sp(O(2))oscillations [1.9 (1.7)%, phase(Pa(O(2))-Sp(O(2))) 264 (72)°] were detected during lung R/D at 1.0. Pa(O(2)) oscillations decreased [2.7 (3.5) kPa, P=0.0008] and Sp(O(2)) oscillations increased [6.8 (3.9)%, P=0.0014] at F(I(O(2))) 0.3. In the brain, synchronized Pbr(O(2)) oscillations [0.6 (0.4) kPa, phase(Pa(O(2))-Pbr(O(2))) 90 (39)°], Sbr(O(2)) oscillations [4.1 (1.5)%, phase(Pa(O(2))-Sbr(O(2))) 182 (54)°], and CBF oscillations [198 (176) AU, phase(Pa(O(2))-CBF) 201 (63)°] occurred that were dependent on Pa(O(2)) and SAP oscillations. Pa(O(2)) oscillations caused by cyclic R/D are transmitted to the cerebral microcirculation in a porcine model of ALI. These cyclic oxygen alterations could play a role in the crosstalk of acute lung and brain injury.
Demirag, Alp; Pastor, Catherine M; Morel, Philippe; Jean-Christophe, Copin; Sielenkämper, Andreas W; Güvener, Nilgun; Mai, Gang; Berney, Thierry; Frossard, Jean-Louis; Bühler, Leo H
2006-01-01
AIM: To investigate the effect of epidural anaesthesia (EA) on pancreatic microcirculation during acute pancreatitis (AP). METHODS: AP was induced by injection of sodium taurocholate into the pancreatic duct of Sprague-Dawley rats. To realize EA, a catheter was introduced into the epidural space between T7 and T9 and bupivacaine was injected. Microcirculatory flow was measured by laser Doppler flowmetry. Arterial blood gas analyses were performed. At the end of the experiment (≤ 5 h), pancreas was removed for histology. The animals were divided into three groups: Group 1 (n = 9), AP without EA; Group 2 (n = 4), EA without AP; and Group 3 (n = 6), AP treated by EA. RESULTS: In Group 1, pancreatic microcirculatory flow prior to AP was 141 ± 39 perfusion units (PU). After AP, microcirculatory flow obviously decreased to 9 ± 6 PU (P < 0.05). Metabolic acidosis developed with base excess (BE) of - 14 ± 3 mmol/L. Histology revealed extensive edema and tissue necrosis. In Group 2, EA did not significantly modify microcirculatory flow. BE remained unchanged and histological analysis showed normal pancreatic tissue. In Group 3, AP initially caused a significant decrease in microcirculatory flow from 155 ± 25 to 11 ± 7 PU (P < 0.05). After initiation of EA, microcirculatory flow obviously increased again to 81 ± 31 PU (P < 0.05). BE was -6 ± 4 mmol/L, which was significantly different compared to Group 1 (P < 0.05). Furthermore, histology revealed less extensive edema and necrosis in pancreatic tissue in Group 3 than that in Group 1. CONCLUSION: AP caused dramatic microcirculatory changes within the pancreas, with development of metabolic acidosis and tissue necrosis. EA allowed partial restoration of microcirculatory flow and prevented development of tissue necrosis and systemic complications. Therefore, EA should be considered as therapeutic option to prevent evolution from edematous to necrotic AP. PMID:16521220
Stanhewicz, Anna E.; Alba, Billie K.; Kenney, W. Larry; Alexander, Lacy M.
2018-01-01
Chronic dairy intake is associated with improved cardiovascular outcomes while high dietary-sodium impairs endothelial function through increased oxidative stress and reduced nitric oxide (NO) bioavailability. The purpose of this study was to compare the effect of acute cheese consumption with consumption of sodium from non-dairy sources on microvascular function. We hypothesized that dairy-cheese ingestion would augment NO-dependent vasodilation compared to sodium from non-dairy sources. On 5 separate visits, 14 healthy subjects (61±2yrs, 8M/6F) consumed either 85g dairy cheese (560mg Na), 85g soy cheese (560mg Na), 65g pretzels (560mg Na), 170g dairy cheese (1120mg Na), or 130g pretzels (1120mg Na). Two intradermal microdialysis fibers were inserted in the ventral forearm for delivery of lactated Ringer’s or 10mM ascorbate (antioxidant) during local skin heating (~50 min). Red cell flux was measured continuously by laser-Doppler flowmetry (LDF) and cutaneous vascular conductance (CVC=LDF/MAP) was normalized as %CVCmax (28mM sodium nitroprusside). Following a plateau in CVC, 15mM NG-nitro-L-arginine methyl ester was perfused to quantify NO-dependent vasodilation (~45 min). NO-dependent vasodilation was greater following dairy (560mg Na 57±3%) (1120mg Na 55±5%) compared to soy (560mg Na 42±3%; p=0.002) or pretzel (560mg Na 43±4%; p=0.004) (1120mg Na 46±3%; p=0.04). Ascorbate augmented NO-dependent vasodilation following soy (control: 42±3 vs. ascorbate: 54±3%; p=0.01) or pretzel (560mg Na; control: 43±4 vs. ascorbate: 56±3%; p=0.006) (1120mg Na; control: 46±5 vs. ascorbate: 56±3%; p=0.02), but not dairy. Sodium ingestion in dairy was associated with greater NO-dependent vasodilation compared to non-dairy sodium, a difference that was ameliorated with ascorbate perfusion. Dairy nutrients may protect against sodium-induced reductions in NO-dependent dilation through ascorbate-sensitive mechanisms. PMID:27363679
Cold Water Mediates Greater Reductions in Limb Blood Flow than Whole Body Cryotherapy.
Mawhinney, Chris; Low, David A; Jones, Helen; Green, Daniel J; Costello, Joseph T; Gregson, Warren
2017-06-01
Cold-water immersion (CWI) and whole body cryotherapy (WBC) are widely used recovery methods in an attempt to limit exercise-induced muscle damage, soreness, and functional deficits after strenuous exercise. The aim of this study was to compare the effects of ecologically valid CWI and WBC protocols on postexercise lower limb thermoregulatory, femoral artery, and cutaneous blood flow responses. Ten males completed a continuous cycle exercise protocol at 70% maximal oxygen uptake until a rectal temperature of 38°C was attained. Participants were then exposed to lower-body CWI (8°C) for 10 min, or WBC (-110°C) for 2 min, in a randomized crossover design. Rectal and thigh skin, deep, and superficial muscle temperatures, thigh, and calf skin blood flow (laser Doppler flowmetry), superficial femoral artery blood flow (duplex ultrasound), and arterial blood pressure were measured before, and for 40 min post, cooling interventions. Greater reductions in thigh skin (CWI, -5.9°C ± 1.8°C; WBC, 0.2°C ± 0.5°C; P < 0.001) and superficial (CWI, -4.4°C ± 1.3°C; WBC, -1.8°C ± 1.1°C; P < 0.001) and deep (CWI, -2.9°C ± 0.8°C; WBC, -1.3°C ± 0.6°C; P < 0.001) muscle temperatures occurred immediately after CWI. Decreases in femoral artery conductance were greater after CWI (CWI, -84% ± 11%; WBC, -59% ± 21%, P < 0.02) and thigh (CWI, -80% ± 5%; WBC, -59% ± 14%, P < 0.001), and calf (CWI, -73% ± 13%; WBC, -45% ± 17%, P < 0.001) cutaneous vasoconstriction was greater after CWI. Reductions in rectal temperature were similar between conditions after cooling (CWI, -0.6°C ± 0.4°C; WBC, -0.6°C ± 0.3°C; P = 0.98). Greater reductions in blood flow and tissue temperature were observed after CWI in comparison with WBC. These novel findings have practical and clinical implications for the use of cooling in the recovery from exercise and injury.
Negrean, Monica; Stirban, Alin; Stratmann, Bernd; Gawlowski, Thomas; Horstmann, Tina; Götting, Christian; Kleesiek, Knut; Mueller-Roesel, Michaela; Koschinsky, Theodor; Uribarri, Jaime; Vlassara, Helen; Tschoepe, Diethelm
2007-05-01
An advanced glycation endproducts (AGEs)-rich diet induces significant increases in inflammatory and endothelial dysfunction markers in type 2 diabetes mellitus (T2DM). The aim was to investigate the acute effects of dietary AGEs on vascular function in T2DM patients. Twenty inpatients with T2DM [x (+/-SEM) age: 55.4 +/- 2.2 y; glycated hemoglobin: 8.8 +/- 0.5%] were investigated. In a randomized crossover design, the effects of a low-AGE (LAGE) and high-AGE (HAGE) meal on macrovascular [by flow-mediated dilatation (FMD)] and microvascular (by Laser-Doppler flowmetry) function, serum markers of endothelial dysfunction (E-selectin, intracellular adhesion molecule 1, and vascular cell adhesion molecule 1), oxidative stress, and serum AGE were assessed. The meals had identical ingredients but different AGE amounts (15.100 compared with 2.750 kU AGE for the HAGE and LAGE meals, respectively), which were obtained by varying the cooking temperature and time. The measurements were performed at baseline and 2, 4, and 6 h after each meal. After the HAGE meal, FMD decreased by 36.2%, from 5.77 +/- 0.65% (baseline) to 3.93 +/- 0.48 (2 h), 3.70 +/- 0.42 (4 h), and 4.42 +/- 0.54% (6 h) (P<0.01 for all compared with baseline). After the LAGE meal, FMD decreased by 20.9%, from 6.04 +/- 0.68% (baseline) to 4.75 +/- 0.48% (2 h), 4.69 +/- 0.51% (4 h), and 5.62 +/- 0.63% (6 h), respectively (P<0.01 for all compared with baseline; P<0.001 for all compared with the HAGE meal). This impairment of macrovascular function after the HAGE meal was paralleled by an impairment of microvascular function (-67.2%) and increased concentrations of serum AGE and markers of endothelial dysfunction and oxidative stress. In patients with T2DM, a HAGE meal induces a more pronounced acute impairment of vascular function than does an otherwise identical LAGE meal. Therefore, chemical modifications of food by means of cooking play a major role in influencing the extent of postprandial vascular dysfunction.
Role of Endocannabinoids and Cannabinoid-1 Receptors in Cerebrocortical Blood Flow Regulation
Horváth, Béla; Benkő, Rita; Lacza, Zsombor; Járai, Zoltán; Sándor, Péter; Di Marzo, Vincenzo; Pacher, Pál; Benyó, Zoltán
2013-01-01
Background Endocannabinoids are among the most intensively studied lipid mediators of cardiovascular functions. In the present study the effects of decreased and increased activity of the endocannabinoid system (achieved by cannabinoid-1 (CB1) receptor blockade and inhibition of cannabinoid reuptake, respectively) on the systemic and cerebral circulation were analyzed under steady-state physiological conditions and during hypoxia and hypercapnia (H/H). Methodology/Principal Findings In anesthetized spontaneously ventilating rats the CB1-receptor antagonist/inverse agonist AM-251 (10 mg/kg, i.v.) failed to influence blood pressure (BP), cerebrocortical blood flow (CoBF, measured by laser-Doppler flowmetry) or arterial blood gas levels. In contrast, the putative cannabinoid reuptake inhibitor AM-404 (10 mg/kg, i.v.) induced triphasic responses, some of which could be blocked by AM-251. Hypertension during phase I was resistant to AM-251, whereas the concomitant CoBF-increase was attenuated. In contrast, hypotension during phase III was sensitive to AM-251, whereas the concomitant CoBF-decrease was not. Therefore, CoBF autoregulation appeared to shift towards higher BP levels after CB1-blockade. During phase II H/H developed due to respiratory depression, which could be inhibited by AM-251. Interestingly, however, the concomitant rise in CoBF remained unchanged after AM-251, indicating that CB1-blockade potentially enhanced the reactivity of the CoBF to H/H. In accordance with this hypothesis, AM-251 induced a significant enhancement of the CoBF responses during controlled stepwise H/H. Conclusion/Significance Under resting physiological conditions CB1-receptor mediated mechanisms appear to have limited influence on systemic or cerebral circulation. Enhancement of endocannabinoid levels, however, induces transient CB1-independent hypertension and sustained CB1-mediated hypotension. Furthermore, enhanced endocannabinoid activity results in respiratory depression in a CB1-dependent manner. Finally, our data indicate for the first time the involvement of the endocannabinoid system and CB1-receptors in the regulation of the cerebral circulation during H/H and also raise the possibility of their contribution to the autoregulation of CoBF. PMID:23308211
Hodges, Gary J; Sharp, Lisa; Stephenson, Claire; Patwala, Ashish Y; George, Keith P; Goldspink, David F; Tim Cable, N
2010-04-01
Skin blood flow (SkBF) and endothelial-dependent vasodilatation decline with ageing and can be reversed with exercise training. We tested whether 48 weeks of training could improve SkBF and endothelial function in post-menopausal females; 20 post-menopausal subjects completed the study. SkBF was measured by laser-Doppler flowmetry (LDF). Cutaneous vascular conductance (CVC) was calculated as LDF/blood pressure. Resting CVC was measured at 32 degrees C and peak CVC at 42 degrees C. Cutaneous endothelial-dependent and -independent vasodilatations were determined by the iontophoresis of acetylcholine (ACh) and sodium nitroprusside (SNP), respectively. All assessments described were performed at entry (week 0), and after 6, 12, 24, 36, and 48 weeks of training. Resting CVC measures did not change (P > 0.05) throughout the study. Peak CVC increased (P < 0.05) after 24 weeks (7.2 +/- 1.2 vs. 11.6 +/- 1.4 AU mmHg(-1)) and at the 36- and 48-week assessments (13.0 +/- 1.7 and 14.9 +/- 2.1 AU mmHg(-1), respectively). Responses to ACh also increased (P < 0.05) at the 24-week assessment (5.1 +/- 2.1 vs. 8.55 +/- 2.3 AU mmHg(-1)) and increased further at the 36 and 48-week assessments (11.6 +/- 3.7 and 13.2 +/- 3.9 AU mmHg(-1), respectively). Cutaneous responses to SNP increased (P < 0.05) after 36 weeks (8.7 +/- 2.1 vs. 13.02 +/- 2.23 AU mmHg(-1) at 36 weeks). VO(2max) increased after 12 weeks (23.5 +/- 0.7 vs. 25.4 +/- 0.9 ml kg(-1) min(-1)) and improved (P < 0.05) further throughout the study (31.6 +/- 1.8 ml kg(-1) min(-1) at week 48). Aerobic exercise produces positive adaptations in the cutaneous vasodilator function to local heating as well as in cutaneous endothelial and endothelial-independent vasodilator mechanisms. Aerobic capacity was also significantly improved. These adaptations were further enhanced with progressive increases in exercise intensity.
Mechanisms and time course of menthol-induced cutaneous vasodilation
Craighead, Daniel H.; McCartney, Nathaniel B.; Tumlinson, James H.; Alexander, Lacy M.
2017-01-01
Menthol is a vasoactive compound that is widely used in topical analgesic agents. Menthol induces cutaneous vasodilation, however the underlying mechanisms are unknown. Determining the rates of appearance and clearance of menthol in the skin is important for optimizing topical treatment formulation and dosing. The purpose of this study was to determine the mechanisms contributing to menthol-mediated cutaneous vasodilation and to establish a time course for menthol appearance/clearance in the skin. Ten young (23±1 years, 5 males 5 females) subjects participated in two protocols. In study 1, four intradermal microdialysis fibers were perfused with increasing doses of menthol (0.1-500mM) and inhibitors for nitric oxide (NO), endothelium derived hyperpolarizing factors (EDHFs), and sensory nerves. Skin blood flow was measured with laser Doppler flowmetry and normalized to %CVCmax. In study 2, two intradermal microdialysis fibers were perfused with lactated Ringer's solution. 0.017mL•cm-2 of a 4% menthol gel was placed over each fiber. 5μL samples of dialysate from the microdialysis fibers were collected every 30 minutes and analyzed for the presence of menthol with high performance gas chromatography/mass spectrometry. Skin blood flow (laser speckle contrast imaging) and subjective ratings of menthol sensation were simultaneously obtained with dialysate samples. In study 1, menthol induced cutaneous vasodilation at all doses ≥100mM (all p<0.05). However, inhibition of either NO, EDHFs, or sensory nerves fully inhibited menthol-mediated vasodilation (all p>0.05). In study 2, significant menthol was detected in dialysate 30 minutes post menthol application (0.89ng, p=0.0002). Relative to baseline, cutaneous vasodilation was elevated from minutes 15-45 and ratings of menthol sensation were elevated from minute 5-60 post menthol application (all p<0.05). Menthol induces cutaneous vasodilation in the skin through multiple vasodilator pathways, including NO, EDHF, and sensory nerves. Topical menthol is detectable in the skin within 30 minutes and is cleared by 60 minutes. Skin blood flow and perceptual measures follow a similar time course as menthol appearance/clearance. PMID:27899298
Penzlin, Ana Isabel; Siepmann, Timo; Illigens, Ben Min-Woo; Weidner, Kerstin; Siepmann, Martin
2015-01-01
Background and objective In patients with alcohol dependence, ethyl-toxic damage of vasomotor and cardiac autonomic nerve fibers leads to autonomic imbalance with neurovascular and cardiac dysfunction, the latter resulting in reduced heart rate variability (HRV). Autonomic imbalance is linked to increased craving and cardiovascular mortality. In this study, we sought to assess the effects of HRV biofeedback training on HRV, vasomotor function, craving, and anxiety. Methods We conducted a randomized controlled study in 48 patients (14 females, ages 25–59 years) undergoing inpatient rehabilitation treatment. In the treatment group, patients (n=24) attended six sessions of HRV biofeedback over 2 weeks in addition to standard rehabilitative care, whereas, in the control group, subjects received standard care only. Psychometric testing for craving (Obsessive Compulsive Drinking Scale), anxiety (Symptom Checklist-90-Revised), HRV assessment using coefficient of variation of R-R intervals (CVNN) analysis, and vasomotor function assessment using laser Doppler flowmetry were performed at baseline, immediately after completion of treatment or control period, and 3 and 6 weeks afterward (follow-ups 1 and 2). Results Psychometric testing showed decreased craving in the biofeedback group immediately postintervention (OCDS scores: 8.6±7.9 post-biofeedback versus 13.7±11.0 baseline [mean ± standard deviation], P<0.05), whereas craving was unchanged at this time point in the control group. Anxiety was reduced at follow-ups 1 and 2 post-biofeedback, but was unchanged in the control group (P<0.05). Following biofeedback, CVNN tended to be increased (10.3%±2.8% post-biofeedback, 10.1%±3.5% follow-up 1, 10.1%±2.9% follow-up 2 versus 9.7%±3.6% baseline; P=not significant). There was no such trend in the control group. Vasomotor function assessed using the mean duration to 50% vasoconstriction of cutaneous vessels after deep inspiration was improved following biofeedback immediately postintervention and was unchanged in the control group (P<0.05). Conclusion Our data indicate that HRV biofeedback might be useful to decrease anxiety, increase HRV, and improve vasomotor function in patients with alcohol dependence when complementing standard rehabilitative inpatient care. PMID:26557753
Rate dependency and role of nitric oxide in the vascular response to direct cooling in human skin.
Yamazaki, Fumio; Sone, Ryoko; Zhao, Kun; Alvarez, Guy E; Kosiba, Wojciech A; Johnson, John M
2006-01-01
Local cooling of nonglabrous skin without functional sympathetic nerves causes an initial vasodilation followed by vasoconstriction. To further characterize these responses to local cooling, we examined the importance of the rate of local cooling and the effect of nitric oxide synthase (NOS) inhibition in intact skin and in skin with vasoconstrictor function inhibited. Release of norepinephrine was blocked locally (iontophoresis) with bretylium tosylate (BT). Skin blood flow was monitored from the forearm by laser-Doppler flowmetry (LDF). Cutaneous vascular conductance (CVC) was calculated as the ratio of LDF to blood pressure. Local temperature was controlled over 6.3 cm2 around the sites of LDF measurement. Local cooling was applied at -0.33 or -4 degrees C/min. At -4 degrees C/min, CVC increased (P < 0.05) at BT sites in the early phase. At -0.33 degrees C/min, there was no early vasodilator response, but there was a delay in the onset of vasoconstriction relative to intact skin. The NOS inhibitor N(G)-nitro-L-arginine methyl ester (L-NAME) (intradermal microdialysis) decreased (P < 0.05) CVC by 28.3 +/- 3.8% at untreated sites and by 46.9 +/- 6.3% at BT-treated sites from the value before infusion. Rapid local cooling (-4 degrees C/min) to 24 degrees C decreased (P < 0.05) CVC at both untreated (saline) sites and L-NAME only sites from the precooling levels, but it transiently increased (P < 0.05) CVC at both BT + saline sites and BT + L-NAME sites in the early phase. After 35-45 min of local cooling, CVC decreased at BT + saline sites relative to the precooling levels (P < 0.05), but at BT + L-NAME sites CVC was not reduced below the precooling level (P = 0.29). These findings suggest that the rate of local cooling, but not functional NOS, is an important determinant of the early non-adrenergic vasodilator response to local cooling and that functional NOS, adrenergic nerves, as well as other mechanisms play roles in vasoconstriction during prolonged local cooling of skin.
Wingo, Jonathan E; Low, David A; Keller, David M; Brothers, R Matthew; Shibasaki, Manabu; Crandall, Craig G
2010-11-01
Sweat rate (SR) is reduced in locally cooled skin, which may result from decreased temperature and/or parallel reductions in skin blood flow. The purpose of this study was to test the hypotheses that decreased skin blood flow and decreased local temperature each independently attenuate sweating. In protocols I and II, eight subjects rested supine while wearing a water-perfused suit for the control of whole body skin and internal temperatures. While 34°C water perfused the suit, four microdialysis membranes were placed in posterior forearm skin not covered by the suit to manipulate skin blood flow using vasoactive agents. Each site was instrumented for control of local temperature and measurement of local SR (capacitance hygrometry) and skin blood flow (laser-Doppler flowmetry). In protocol I, two sites received norepinephrine to reduce skin blood flow, while two sites received Ringer solution (control). All sites were maintained at 34°C. In protocol II, all sites received 28 mM sodium nitroprusside to equalize skin blood flow between sites before local cooling to 20°C (2 sites) or maintenance at 34°C (2 sites). In both protocols, individuals were then passively heated to increase core temperature ~1°C. Both decreased skin blood flow and decreased local temperature attenuated the slope of the SR to mean body temperature relationship (2.0 ± 1.2 vs. 1.0 ± 0.7 mg·cm(-2)·min(-1)·°C(-1) for the effect of decreased skin blood flow, P = 0.01; 1.2 ± 0.9 vs. 0.07 ± 0.05 mg·cm(-2)·min(-1)·°C(-1) for the effect of decreased local temperature, P = 0.02). Furthermore, local cooling delayed the onset of sweating (mean body temperature of 37.5 ± 0.4 vs. 37.6 ± 0.4°C, P = 0.03). These data demonstrate that local cooling attenuates sweating by independent effects of decreased skin blood flow and decreased local skin temperature.
Decreased active vasodilator sensitivity in aged skin.
Kenney, W L; Morgan, A L; Farquhar, W B; Brooks, E M; Pierzga, J M; Derr, J A
1997-04-01
Older men and women respond to local and reflex-mediated heat stress with an attenuated increase in cutaneous vascular conductance (CVC). This study was performed to test the hypothesis that an augmented or sustained noradrenergic vasoconstriction (VC) may play a role in this age-related difference. Fifteen young (22 +/- 1 yr) and 15 older (66 +/- 1 yr) men exercised at 50% peak oxygen uptake in a 36 degrees C environment. Skin perfusion was monitored at two sites on the right forearm by laser-Doppler flowmetry: one site pretreated with bretylium tosylate (BT) to block the local release of norepinephrine and thus VC and an adjacent control site. Blockade of reflex VC was verified during whole body cooling using a water-perfused suit. CVC (perfusion divided by mean arterial pressure) at each site was reported as a percentage of the maximal CVC (%CVCmax) induced at the end of each experiment by prolonged local heating at 42 degrees C. Neither age nor BT affected the %CVCmax (75-86%) attained at high core temperatures. During the early rise phase of CVC, the %CVCmax-change in esophageal temperature (delta T(es)) curve was shifted to the right in the older men (effective delta T(es) associated with 50% CVC response for young, 0.22 +/- 0.04 and 0.39 +/- 0.04 degrees C and for older, 0.73 +/- 0.04 and 0.85 +/- 0.04 degrees C at control and BT sites, respectively). BT had no interactive effect on this age difference, suggesting a lack of involvement of the VC system in the attenuated CVC response of individuals over the age of 60 yr. Additionally, increases in skin vascular conductance were quantitatively compared by measuring increases in total forearm vascular conductance (FVC, restricted to the forearm skin under these conditions). After the initial approximately 0.2 degrees C increase in T(es), FVC was 40-50% lower in the older men (P < 0.01) for the remainder of the exercise. Decreased active vasodilator sensitivity to increasing core temperature, coupled with structural limitations to vasodilation, appears to limit the cutaneous vascular response to exertional heat stress in older subjects.
Alvarez, Guy E; Zhao, Kun; Kosiba, Wojciech A; Johnson, John M
2006-06-01
The reduction in skin blood flow (SkBF) with cold exposure is partly due to the reflex vasoconstrictor response from whole body cooling (WBC) and partly to the direct effects of local cooling (LC). Although these have been examined independently, little is known regarding their roles when acting together, as occurs in environmental cooling. We tested the hypothesis that the vasoconstrictor response to combined LC and WBC would be additive, i.e., would equal the sum of their independent effects. We further hypothesized that LC would attenuate the reflex vasoconstrictor response to WBC. We studied 16 (7 women, 9 men) young (30.5+/-2 yr) healthy volunteers. LC and WBC were accomplished with metal Peltier cooler-heater probe holders and water-perfused suits, respectively. Forearm SkBF was monitored by laser-Doppler flowmetry (LDF). Cutaneous vascular conductance (CVC) was calculated as LDF/blood pressure. Subjects underwent 15 min of LC alone or 15 min of WBC with and without simultaneous LC, either at equal levels (34-31 degrees C) or as equipotent stimuli (34-28 degrees C LC; 34-31 degrees C WBC). The fall in CVC with combined WBC and LC was greater (P<0.05) than for either alone (57.0+/-5% combined vs. 39.2+/-6% WBC; 34.4+/-4% LC) with equipotent cooling, but it was only significantly greater than for LC alone with equal levels of cooling (51.3+/-8% combined vs. 29.5+/-4% LC). The sum of the independent effects of WBC and LC was greater than their combined effects (74.9+/-4 vs. 51.3+/-8% equal and 73.6+/-7 vs. 57.0+/-5% equipotent; P<0.05). The fall in CVC with WBC at LC sites was reduced compared with control sites (17.6+/-2 vs. 42.4+/-8%; P<0.05). Hence, LC contributes importantly to the reduction in SkBF with body cooling, but also suppresses the reflex response, resulting in a nonadditive effect of these two components.
NASA Technical Reports Server (NTRS)
Golanov, E. V.; Reis, D. J.
1996-01-01
1. We sought to determine whether hypoxic stimulation of neurons of the rostral ventrolateral reticular nucleus (RVL) would elevate regional cerebral blood flow (rCBF) in anaesthetized paralysed rats. 2. Microinjection of sodium cyanide (NaCN; 150-450 pmol) into the RVL rapidly (within 1-2 s), transiently, dose-dependently and site-specifically elevated rCBF1 measured by laser Doppler flowmetry, by 61.3 +/- 22.1% (P < 0.01), increased arterial pressure (AP; +30 +/- 8 mmHg; P < 0.01)1 and triggered a synchronized 6 Hz rhythm of EEG activity. 3. Following cervical spinal cord transection, NaCN and also dinitrophenol (DNP) significantly (P < 0.05) elevated rCBF and synchronized the EEG but did not elevate AP; the response to NaCN was attenuated by hyperoxia and deepening of anaesthesia. 4. Electrical stimulation of NaCN-sensitive sites in the RVL in spinalized rats increased rCBF measured autoradiographically with 14C iodoantipyrine (Kety method) in the mid-line thalamus (by 182.3 +/- 17.2%; P < 0.05) and cerebral cortex (by 172.6 +/- 15.6%; P < 0.05) regions, respectively, directly or indirectly innervated by RVL neurons, and in the remainder of the brain. In contrast regional cerebral glucose utilization (rCGU), measured autoradiographically with 14C-2-deoxyglucose (Sokoloff method), was increased in proportion to rCBF in the mid-line thalamus (165.6 +/- 17.8%, P < 0.05) but was unchanged in the cortex. 5. Bilateral electrolytic lesions of NaCN sensitive sites of RVL, while not altering resting rCBF or the elevation elicited by hypercarbia (arterial CO2 pressure, Pa,CO2, approximately 69 mmHg), reduced the vasodilatation elicited by normocapnic hypoxaemia (arterial O2 pressure, Pa,O2, approximately 27 mmHg) by 67% (P < 0.01) and flattened the slope of the Pa,O2-rCBF response curve. 6. We conclude that the elevation of rCBF produced in the cerebral cortex by hypoxaemia is in large measure neurogenic, mediated trans-synaptically over intrinsic neuronal pathways, and initiated by excitation of oxygen sensitive neurons in the RVL.
Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares
2018-02-01
We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p < 0.0005). Aortic flow showed no difference between ECG- and Doppler-triggered and MOG (p > 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.
A new method for blood velocity measurements using ultrasound FMCW signals.
Kunita, Masanori; Sudo, Masamitsu; Inoue, Shinya; Akahane, Mutsuhiro
2010-05-01
The low peak power of frequency-modulated continuous wave (FMCW) radar makes it attractive for various applications, including vehicle collision warning systems and airborne radio altimeters. This paper describes a new ultrasound Doppler measurement system that measures blood flow velocity based on principles similar to those of FMCW radar. We propose a sinusoidal wave for FM modulation and introduce a new demodulation technique for obtaining Doppler information with high SNR and range resolution. Doppler signals are demodulated with a reference FMCW signal to adjust delay times so that they are equal to propagation times between the transmitter and the receiver. Analytical results suggest that Doppler signals can be obtained from a selected position, as with a sample volume in pulse wave Doppler systems, and that the resulting SNR is nearly identical to that obtained with continuous wave (CW) Doppler systems. Additionally, clutter power is less than that of CW Doppler systems. The analytical results were verified by experiments involving electronic circuits and Doppler ultrasound phantoms.
Coherent Doppler lidar signal covariance including wind shear and wind turbulence
NASA Technical Reports Server (NTRS)
Frehlich, R. G.
1993-01-01
The performance of coherent Doppler lidar is determined by the statistics of the coherent Doppler signal. The derivation and calculation of the covariance of the Doppler lidar signal is presented for random atmospheric wind fields with wind shear. The random component is described by a Kolmogorov turbulence spectrum. The signal parameters are clarified for a general coherent Doppler lidar system. There are two distinct physical regimes: one where the transmitted pulse determines the signal statistics and the other where the wind field dominates the signal statistics. The Doppler shift of the signal is identified in terms of the wind field and system parameters.
Temporal Doppler Effect and Future Orientation: Adaptive Function and Moderating Conditions.
Gan, Yiqun; Miao, Miao; Zheng, Lei; Liu, Haihua
2017-06-01
The objectives of this study were to examine whether the temporal Doppler effect exists in different time intervals and whether certain individual and environmental factors act as moderators of the effect. Using hierarchical linear modeling, we examined the existence of the temporal Doppler effect and the moderating effect of future orientation among 139 university students (Study 1), and then the moderating conditions of the temporal Doppler effect using two independent samples of 143 and 147 university students (Studies 2 and 3). Results indicated that the temporal Doppler effect existed in all of our studies, and that future orientation moderated the temporal Doppler effect. Further, time interval perception mediated the relationship between future orientation and the motivation to cope at long time intervals. Finally, positive affect was found to enhance the temporal Doppler effect, whereas control deprivation did not influence the effect. The temporal Doppler effect is moderated by the personality trait of future orientation and by the situational variable of experimentally manipulated positive affect. We have identified personality and environmental processes that could enhance the temporal Doppler effect, which could be valuable in cases where attention to a future task is necessary. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Bocanegra-Bahamón, T. M.; Molera Calvés, G.; Gurvits, L. I.; Duev, D. A.; Pogrebenko, S. V.; Cimò, G.; Dirkx, D.; Rosenblatt, P.
2018-01-01
Context. Closed-loop Doppler data obtained by deep space tracking networks, such as the NASA Deep Space Network (DSN) and the ESA tracking station network (Estrack), are routinely used for navigation and science applications. By shadow tracking the spacecraft signal, Earth-based radio telescopes involved in the Planetary Radio Interferometry and Doppler Experiment (PRIDE) can provide open-loop Doppler tracking data only when the dedicated deep space tracking facilities are operating in closed-loop mode. Aims: We explain the data processing pipeline in detail and discuss the capabilities of the technique and its potential applications in planetary science. Methods: We provide the formulation of the observed and computed values of the Doppler data in PRIDE tracking of spacecraft and demonstrate the quality of the results using an experiment with the ESA Mars Express spacecraft as a test case. Results: We find that the Doppler residuals and the corresponding noise budget of the open-loop Doppler detections obtained with the PRIDE stations compare to the closed-loop Doppler detections obtained with dedicated deep space tracking facilities.
Optimized doppler optical coherence tomography for choroidal capillary vasculature imaging
NASA Astrophysics Data System (ADS)
Liu, Gangjun; Qi, Wenjuan; Yu, Lingfeng; Chen, Zhongping
2011-03-01
In this paper, we analyzed the retinal and choroidal blood vasculature in the posterior segment of the human eye with optimized color Doppler and Doppler variance optical coherence tomography. Depth-resolved structure, color Doppler and Doppler variance images were compared. Blood vessels down to capillary level were able to be obtained with the optimized optical coherence color Doppler and Doppler variance method. For in-vivo imaging of human eyes, bulkmotion induced bulk phase must be identified and removed before using color Doppler method. It was found that the Doppler variance method is not sensitive to bulk motion and the method can be used without removing the bulk phase. A novel, simple and fast segmentation algorithm to indentify retinal pigment epithelium (RPE) was proposed and used to segment the retinal and choroidal layer. The algorithm was based on the detected OCT signal intensity difference between different layers. A spectrometer-based Fourier domain OCT system with a central wavelength of 890 nm and bandwidth of 150nm was used in this study. The 3-dimensional imaging volume contained 120 sequential two dimensional images with 2048 A-lines per image. The total imaging time was 12 seconds and the imaging area was 5x5 mm2.
Cruz-Martinez, R; Savchev, S; Cruz-Lemini, M; Mendez, A; Gratacos, E; Figueras, F
2015-03-01
To assess the clinical value of third-trimester uterine artery (UtA) Doppler ultrasound in the prediction of hemodynamic deterioration and adverse perinatal outcome in term small-for-gestational-age (SGA) fetuses. UtA Doppler parameters, cerebroplacental ratio (CPR) and fetal middle cerebral artery (MCA) pulsatility index (PI) were evaluated weekly, starting from the time of SGA diagnosis until 24 h before induction of labor, in a cohort of 327 SGA fetuses with normal umbilical artery PI (< 95th centile), delivered at > 37 weeks' gestation. Differences in the sequence of CPR and MCA-PI changes < 5th centile, between the group with normal UtA Doppler indices at diagnosis and those with abnormal UtA indices, were analyzed by survival analysis. In addition, the use of UtA Doppler value, alone or in combination with a brain Doppler scan before delivery, to predict the risk of Cesarean section, Cesarean section for non-reassuring fetal status (NRFS), neonatal acidosis and neonatal hospitalization was evaluated by logistic regression analysis, adjusted for gestational age at birth and birth-weight percentile. Abnormal UtA Doppler at diagnosis of SGA was associated with a higher risk of developing abnormal brain Doppler indices before induction of labor than in those with a normal UtA at diagnosis (62.7% vs 34.6%, respectively; P < 0.01). Compared to those with normal UtA Doppler indices, those with abnormal UtA Doppler findings were associated with a higher risk of intrapartum Cesarean section (52.2% vs 37.3%, respectively; P = 0.03), Cesarean section for NRFS (35.8% vs 23.1%, respectively; P = 0.03), neonatal acidosis (10.4% vs 7.7%, respectively; P = 0.47) and neonatal hospitalization (23.9% vs 16.5%, respectively; P = 0.16). Logistic regression analysis indicated that UtA Doppler findings were not significantly associated with adverse perinatal outcome independent of brain Doppler findings. UtA Doppler indices predict adverse perinatal outcome, but do not help to improve the predictive value of brain Doppler indices. However, at the time of SGA diagnosis they identify the subgroup of fetuses at highest risk of progression to abnormal brain Doppler findings. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
A New Active Cavitation Mapping Technique for Pulsed HIFU Applications – Bubble Doppler
Li, Tong; Khokhlova, Tatiana; Sapozhnikov, Oleg; Hwang, Joo Ha; Sapozhnikov, Oleg; O’Donnell, Matthew
2015-01-01
In this work, a new active cavitation mapping technique for pulsed high-intensity focused ultrasound (pHIFU) applications termed bubble Doppler is proposed and its feasibility tested in tissue-mimicking gel phantoms. pHIFU therapy uses short pulses, delivered at low pulse repetition frequency, to cause transient bubble activity that has been shown to enhance drug and gene delivery to tissues. The current gold standard for detecting and monitoring cavitation activity during pHIFU treatments is passive cavitation detection (PCD), which provides minimal information on the spatial distribution of the bubbles. B-mode imaging can detect hyperecho formation, but has very limited sensitivity, especially to small, transient microbubbles. The bubble Doppler method proposed here is based on a fusion of the adaptations of three Doppler techniques that had been previously developed for imaging of ultrasound contrast agents – color Doppler, pulse inversion Doppler, and decorrelation Doppler. Doppler ensemble pulses were interleaved with therapeutic pHIFU pulses using three different pulse sequences and standard Doppler processing was applied to the received echoes. The information yielded by each of the techniques on the distribution and characteristics of pHIFU-induced cavitation bubbles was evaluated separately, and found to be complementary. The unified approach - bubble Doppler – was then proposed to both spatially map the presence of transient bubbles and to estimate their sizes and the degree of nonlinearity. PMID:25265178
Doppler color imaging. Principles and instrumentation.
Kremkau, F W
1992-01-01
DCI acquires Doppler-shifted echoes from a cross-section of tissue scanned by an ultrasound beam. These echoes are then presented in color and superimposed on the gray-scale anatomic image of non-Doppler-shifted echoes received during the scan. The flow echoes are assigned colors according to the color map chosen. Usually red, yellow, or white indicates positive Doppler shifts (approaching flow) and blue, cyan, or white indicates negative shifts (receding flow). Green is added to indicate variance (disturbed or turbulent flow). Several pulses (the number is called the ensemble length) are needed to generate a color scan line. Linear, convex, phased, and annular arrays are used to acquire the gray-scale and color-flow information. Doppler color-flow instruments are pulsed-Doppler instruments and are subject to the same limitations, such as Doppler angle dependence and aliasing, as other Doppler instruments. Color controls include gain, TGC, map selection, variance on/off, persistence, ensemble length, color/gray priority. Nyquist limit (PRF), baseline shift, wall filter, and color window angle, location, and size. Doppler color-flow instruments generally have output intensities intermediate between those of gray-scale imaging and pulsed-Doppler duplex instruments. Although there is no known risk with the use of color-flow instruments, prudent practice dictates that they be used for medical indications and with the minimum exposure time and instrument output required to obtain the needed diagnostic information.
Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions
Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati
2011-01-01
Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940
Rabba, Silvia; Grulke, Sigrid; Verwilghen, Denis; Evrard, Laurence; Busoni, Valeria
2018-03-01
Ultrasonography is routinely used to achieve the diagnosis of equine suspensory ligament desmopathy. In human medicine, power Doppler ultrasonography has also been found to be useful for the diagnosis of tendon/ligament injuries. The aim of this prospective, pilot study was to assess the presence or absence of power Doppler signal in suspensory ligament branches and compare B-mode findings with power Doppler findings in suspensory ligament branches of lame and non-lame limbs. Thirteen horses were used (eight lame horses, with lameness related to pain in the suspensory ligament branches, and five non-lame horses). Ten lame limbs and 24 sound limbs were assessed by B-mode and power Doppler ultrasonography. The severity of power Doppler signal was scored by two independent readers. The B-mode ultrasonographic examination revealed abnormalities in branches of lame limbs and in branches of sound limbs. Suspensory ligament branches that were considered normal in B-mode showed no power Doppler signal. However, power Doppler signal was detected in suspensory ligament branches that were abnormal in B-mode, both in lame and sound limbs. Power Doppler scores were subjectively higher in suspensory ligament branches of lame limbs and in branches with more severe B-mode changes. Findings supported the use of power Doppler as an adjunctive diagnostic test for lame horses with suspected suspensory desmopathy. © 2018 American College of Veterinary Radiology.
Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.
Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P
1995-01-01
Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.
Finnish Meteorological Institute Doppler Lidar
Ewan OConnor
2015-03-27
This doppler lidar system provides co-polar and cross polar attenuated backscatter coefficients,signal strength, and doppler velocities in the cloud and in the boundary level, including uncertainties for all parameters. Using the doppler beam swinging DBS technique, and Vertical Azimuthal Display (VAD) this system also provides vertical profiles of horizontal winds.
IIP Update: A Packaged Coherent Doppler Wind Lidar Transceiver. Doppler Aerosol WiNd Lidar (DAWN)
NASA Technical Reports Server (NTRS)
Kavaya, Michael J.; Koch, Grady J.; Yu, Jirong; Trieu, Bo C.; Amzajerdian, Farzin; Singh, Upendra N.; Petros, Mulugeta
2006-01-01
The state-of-the-art 2-micron coherent Doppler wind lidar breadboard at NASA/LaRC will be engineered and compactly packaged consistent with future aircraft flights. The packaged transceiver will be integrated into a coherent Doppler wind lidar system test bed at LaRC. Atmospheric wind measurements will be made to validate the packaged technology. This will greatly advance the coherent part of the hybrid Doppler wind lidar solution to the need for global tropospheric wind measurements.
Doppler and range determination for deep space vehicles using active optical transponders.
Kinman, P W; Gagliardi, R M
1988-11-01
This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.
Doppler and range determination for deep space vehicles using active optical transponders
NASA Technical Reports Server (NTRS)
Kinman, Peter W.; Gagliardi, Robert M.
1988-01-01
This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.
The application of coded excitation technology in medical ultrasonic Doppler imaging
NASA Astrophysics Data System (ADS)
Li, Weifeng; Chen, Xiaodong; Bao, Jing; Yu, Daoyin
2008-03-01
Medical ultrasonic Doppler imaging is one of the most important domains of modern medical imaging technology. The application of coded excitation technology in medical ultrasonic Doppler imaging system has the potential of higher SNR and deeper penetration depth than conventional pulse-echo imaging system, it also improves the image quality, and enhances the sensitivity of feeble signal, furthermore, proper coded excitation is beneficial to received spectrum of Doppler signal. Firstly, this paper analyzes the application of coded excitation technology in medical ultrasonic Doppler imaging system abstractly, showing the advantage and bright future of coded excitation technology, then introduces the principle and the theory of coded excitation. Secondly, we compare some coded serials (including Chirp and fake Chirp signal, Barker codes, Golay's complementary serial, M-sequence, etc). Considering Mainlobe Width, Range Sidelobe Level, Signal-to-Noise Ratio and sensitivity of Doppler signal, we choose Barker codes as coded serial. At last, we design the coded excitation circuit. The result in B-mode imaging and Doppler flow measurement coincided with our expectation, which incarnated the advantage of application of coded excitation technology in Digital Medical Ultrasonic Doppler Endoscope Imaging System.
A Doppler centroid estimation algorithm for SAR systems optimized for the quasi-homogeneous source
NASA Technical Reports Server (NTRS)
Jin, Michael Y.
1989-01-01
Radar signal processing applications frequently require an estimate of the Doppler centroid of a received signal. The Doppler centroid estimate is required for synthetic aperture radar (SAR) processing. It is also required for some applications involving target motion estimation and antenna pointing direction estimation. In some cases, the Doppler centroid can be accurately estimated based on available information regarding the terrain topography, the relative motion between the sensor and the terrain, and the antenna pointing direction. Often, the accuracy of the Doppler centroid estimate can be improved by analyzing the characteristics of the received SAR signal. This kind of signal processing is also referred to as clutterlock processing. A Doppler centroid estimation (DCE) algorithm is described which contains a linear estimator optimized for the type of terrain surface that can be modeled by a quasi-homogeneous source (QHS). Information on the following topics is presented: (1) an introduction to the theory of Doppler centroid estimation; (2) analysis of the performance characteristics of previously reported DCE algorithms; (3) comparison of these analysis results with experimental results; (4) a description and performance analysis of a Doppler centroid estimator which is optimized for a QHS; and (5) comparison of the performance of the optimal QHS Doppler centroid estimator with that of previously reported methods.
Is Doppler tissue velocity during early left ventricular filling preload independent?
NASA Technical Reports Server (NTRS)
Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.
2002-01-01
BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.
Coherent Doppler lidar for measurements of wind fields
NASA Technical Reports Server (NTRS)
Menzies, Robert T.; Hardesty, R. Michael
1989-01-01
The signal-processing techniques for obtaining the velocity estimates and the fundamental factors that influence coherent lidar performance are considered. The similarities and distinctions between Doppler lidar and Doppler radars are discussed. The capability of coherent Doppler lidars for mapping wind fields over selected regions in the lower atmosphere and greatly enhancing the capability to visualize flow patterns in real time is discussed, and examples are given. Salient features of a concept for an earth-orbiting Doppler lidar to be launched in the late 1990s are examined.
Orbit determination singularities in the Doppler tracking of a planetary orbiter
NASA Technical Reports Server (NTRS)
Wood, L. J.
1985-01-01
On a number of occasions, spacecraft launched by the U.S. have been placed into orbit about the moon, Venus, or Mars. It is pointed out that, in particular, in planetary orbiter missions two-way coherent Doppler data have provided the principal data type for orbit determination applications. The present investigation is concerned with the problem of orbit determination on the basis of Doppler tracking data in the case of a spacecraft in orbit about a natural body other than the earth or the sun. Attention is given to Doppler shift associated with a planetary orbiter, orbit determination using a zeroth-order model for the Doppler shift, and orbit determination using a first-order model for the Doppler shift.
Navigator alignment using radar scan
Doerry, Armin W.; Marquette, Brandeis
2016-04-05
The various technologies presented herein relate to the determination of and correction of heading error of platform. Knowledge of at least one of a maximum Doppler frequency or a minimum Doppler bandwidth pertaining to a plurality of radar echoes can be utilized to facilitate correction of the heading error. Heading error can occur as a result of component drift. In an ideal situation, a boresight direction of an antenna or the front of an aircraft will have associated therewith at least one of a maximum Doppler frequency or a minimum Doppler bandwidth. As the boresight direction of the antenna strays from a direction of travel at least one of the maximum Doppler frequency or a minimum Doppler bandwidth will shift away, either left or right, from the ideal situation.
Efeitos do binarismo não resolvido na determinação da função de massa de aglomerados
NASA Astrophysics Data System (ADS)
Kerber, L. O.; Santiago, B. X.
2003-08-01
Através de simulações numéricas buscamos quantificar os efeitos que o binarismo não resolvido causa na determinação da função de massa (MF) de aglomerados estelares. Geramos diagramas cor-magnitude (CMDs) artificiais simulando uma população única, caracterizada por estrelas de mesma idade e composição quí mica, com uma fração de binárias não resolvidas e distribuição em massa das estrelas dada por uma MF do tipo lei de potência. A presença de pares de estrelas não resolvidos faz com que a MF obtida da função de luminosidade (LF) tenha a têndencia de ser mais plana do que a MF que gerou o CMD artificial. Propomos um tratamento de correção para tal efeito. Outro efeito relacionado diz respeito ao alargamento do CMD, que apresenta-se como um indicador do número total de estrelas no domí nio de baixas massas (m < 0.6M¤). Todos os resultados acima possuem uma forte dependência com os erros fotométricos e estão baseados na hipótese de que ambas estrelas do par não resolvido são sorteadas de uma mesma MF de forma independente. O objetivo final é aplicarmos o tratamento aqui desenvolvido para implementarmos a análise da nossa amostra de aglomerados ricos da Grande Nuvem de Magalhães.
Doppler effect of subluminal and superluminal sources in eight dimensions
NASA Astrophysics Data System (ADS)
Chandola, H. C.; Rajput, B. S.
1984-06-01
The study of the relativistic Doppler effect of subliminal and superluminal sources has been undertaken in the eight-dimensional space. It has been shown that correct Doppler shifts are obtained in the external spaces of these sources and the conformal correspondence between Doppler effect curves holds in case of approaching and receeding sources but not in the transverse case.
Viking S-band Doppler RMS phase fluctuations used to calibrate the mean 1976 equatorial corona
NASA Technical Reports Server (NTRS)
Berman, A. L.; Wackley, J. A.
1977-01-01
Viking S-band Doppler RMS phase fluctuations (noise) and comparisons of Viking Doppler noise to Viking differenced S-X range measurements are used to construct a mean equatorial electron density model for 1976. Using Pioneer Doppler noise results (at high heliographic latitudes, also from 1976), an equivalent nonequatorial electron density model is approximated.
Ultrasonic Methods for Human Motion Detection
2006-10-01
contacts. The active method utilizes continuous wave ultrasonic Doppler sonar . Human motions have unique Doppler signatures and their combination...The present article reports results of human motion investigations with help of CW ultrasonic Doppler sonar . Low-cost, low-power ultrasonic motion...have been developed for operation in air [10]. Benefits of using ultrasonic CW Doppler sonar included the low-cost, low-electric noise, small size
NASA Technical Reports Server (NTRS)
Beyon, Jeffrey Y.; Koch, Grady J.
2006-01-01
The signal processing aspect of a 2-m wavelength coherent Doppler lidar system under development at NASA Langley Research Center in Virginia is investigated in this paper. The lidar system is named VALIDAR (validation lidar) and its signal processing program estimates and displays various wind parameters in real-time as data acquisition occurs. The goal is to improve the quality of the current estimates such as power, Doppler shift, wind speed, and wind direction, especially in low signal-to-noise-ratio (SNR) regime. A novel Nonlinear Adaptive Doppler Shift Estimation Technique (NADSET) is developed on such behalf and its performance is analyzed using the wind data acquired over a long period of time by VALIDAR. The quality of Doppler shift and power estimations by conventional Fourier-transform-based spectrum estimation methods deteriorates rapidly as SNR decreases. NADSET compensates such deterioration in the quality of wind parameter estimates by adaptively utilizing the statistics of Doppler shift estimate in a strong SNR range and identifying sporadic range bins where good Doppler shift estimates are found. The authenticity of NADSET is established by comparing the trend of wind parameters with and without NADSET applied to the long-period lidar return data.
Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli.
Moehring, Mark A; Spencer, Merrill P
2002-01-01
Difficulties in location of transcranial ultrasound (US) windows and blood flow in cerebral vessels, and unambiguous detection of microemboli, have limited expansion of transcranial Doppler US. We developed a new transcranial Doppler modality, power M-mode Doppler (PMD), for addressing these issues. A 2-MHz digital Doppler (Spencer Technologies TCD100M) having 33 sample gates placed with 2-mm spacing was configured to display Doppler signal power, colored red and blue for directionality, in an M-mode format. The spectrogram from a user-selected depth was displayed simultaneously. This system was then explored on healthy subjects and patients presenting with varying cerebrovascular pathology. PMD facilitated window location and alignment of the US beam to view blood flow from multiple vessels simultaneously, without sound or spectral clues. Microemboli appeared as characteristic sloping high-power tracks in the PMD image. Power M-mode Doppler is a new paradigm facilitating vessel location, diagnosis, monitoring and microembolus detection.
Doppler-corrected differential detection system
NASA Technical Reports Server (NTRS)
Simon, Marvin K. (Inventor); Divsalar, Dariush (Inventor)
1991-01-01
Doppler in a communication system operating with a multiple differential phase-shift-keyed format (MDPSK) creates an adverse phase shift in an incoming signal. An open loop frequency estimation is derived from a Doppler-contaminated incoming signal. Based upon the recognition that, whereas the change in phase of the received signal over a full symbol contains both the differentially encoded data and the Doppler induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler induced phase shift, and the Doppler effect can be estimated and removed from the incoming signal. Doppler correction occurs prior to the receiver's final output of decoded data. A multiphase system can operate with two samplings per symbol interval at no penalty in signal-to-noise ratio provided that an ideal low pass pre-detection filter is employed, and two samples, at 1/4 and 3/4 of the symbol interval T sub s, are taken and summed together prior to incoming signal data detection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greebler, P.; Goldman, E.
1962-12-19
Doppler calculations for large fast ceramic reactors (FCR), using recent cross section information and improved methods, are described. Cross sections of U/sup 238/, Pu/sup 239/, and Pu/sup 210/ with fuel temperature variations needed for perturbation calculations of Doppler reactivity changes are tabulated as a function of potential scattering cross section per absorber isotope at energies below 400 kev. These may be used in Doppler calculations for anv fast reactor. Results of Doppler calculations on a large fast ceramic reactor are given to show the effects of the improved calculation methods and of recent cross secrion data on the calculated Dopplermore » coefficient. The updated methods and cross sections used yield a somewhat harder spectrum and accordingly a somewhat smaller Doppler coefficient for a given FCR core size and composition than calculated in earlier work, but they support the essential conclusion derived earlier that the Doppler effect provides an important safety advantage in a large FCR. 28 references. (auth)« less
NASA Technical Reports Server (NTRS)
Berman, A. L.; Wackley, J. A.; Rockwell, S. T.; Yee, J. G.
1976-01-01
The 1976 Pioneer II Solar Conjunction provided the opportunity to accumulate a substantial quantity of doppler noise data over a dynamic range of signal closest approach point heliographic latitudes. The observed doppler noise data were fit to the doppler noise model ISED, and the deviations of the observed doppler noise data from the model were used to construct a (multiplicative) function to describe the effect of heliographic latitude. This expression was then incorporated into the ISED model to produce a new doppler noise model-ISEDB.
Li, Min; Yu, Bing-bing; Wu, Jian-hua; Xu, Lin; Sun, Gang
2013-01-01
Purpose As Doppler ultrasound has been proven to be an effective tool to predict and compress the optimal pulsing windows, we evaluated the effective dose and diagnostic accuracy of coronary CT angiography (CTA) incorporating Doppler-guided prospective electrocardiograph (ECG) gating, which presets pulsing windows according to Doppler analysis, in patients with a heart rate >65 bpm. Materials and Methods 119 patients with a heart rate >65 bpm who were scheduled for invasive coronary angiography were prospectively studied, and patients were randomly divided into traditional prospective (n = 61) and Doppler-guided prospective (n = 58) ECG gating groups. The exposure window of traditional prospective ECG gating was set at 30%–80% of the cardiac cycle. For the Doppler group, the length of diastasis was analyzed by Doppler. For lengths greater than 90 ms, the pulsing window was preset during diastole (during 60%–80%); otherwise, the optimal pulsing intervals were moved from diastole to systole (during 30%–50%). Results The mean heart rates of the traditional ECG and the Doppler-guided group during CT scanning were 75.0±7.7 bpm (range, 66–96 bpm) and 76.5±5.4 bpm (range: 66–105 bpm), respectively. The results indicated that whereas the image quality showed no significant difference between the traditional and Doppler groups (P = 0.42), the radiation dose of the Doppler group was significantly lower than that of the traditional group (5.2±3.4mSv vs. 9.3±4.5mSv, P<0.001). The sensitivities of CTA applying traditional and Doppler-guided prospective ECG gating to diagnose stenosis on a segment level were 95.5% and 94.3%, respectively; specificities 98.0% and 97.1%, respectively; positive predictive values 90.7% and 88.2%, respectively; negative predictive values 99.0% and 98.7%, respectively. There was no statistical difference in concordance between the traditional and Doppler groups (P = 0.22). Conclusion Doppler-guided prospective ECG gating represents an improved method in patients with a high heart rate to reduce effective radiation doses, while maintaining high diagnostic accuracy. PMID:23696793
Analysis of Doppler Lidar Data Acquired During the Pentagon Shield Field Campaign
2011-04-01
two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the...Observations from two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to... coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the overall
Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea
2011-06-01
We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Kim, Dohyun; Park, Sung-Ho
2016-11-01
Recently, Doppler ultrasound has been used for the measurement of pulpal blood flow in human teeth. However, the reliability of this method has not been verified. In this study, we developed a model to simulate arteriole blood flow within the dental pulp by using microfluidics. This arteriole simulator, or flow phantom, was used to determine the reliability of measurements obtained by using a Doppler ultrasound device. A microfluidic chip was fabricated by using the soft lithography technique, and blood-mimicking fluid was pumped through the channel by a microfluidic system. A Doppler ultrasound device was used for the measurement of flow velocity. The peak, mean, and minimal flow velocities obtained from the phantom and the Doppler ultrasound device were compared by using linear regression analysis and Pearson correlation coefficient. Bland-Altman analyses were performed to evaluate the velocity differences between the flow generated by the phantom and the flow measurements made with the Doppler ultrasound device. The microfluidic system was able to generate the flow profiles as intended, and the fluid flow could be monitored and controlled by the software program. There were excellent linear correlations between the peak, mean, and minimal flow velocities of the phantom and those of the Doppler ultrasound device (r = 0.94-0.996, P < .001). However, the velocities were overestimated by the Doppler ultrasound device. This phantom provides opportunities for research and education involving the Doppler ultrasound technique in dentistry. Although Doppler ultrasound can be an effective tool for the measurement of pulpal blood flow velocity, it is essential to validate and calibrate the device before clinical use. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Shima, Toshihide; Mizuno, Masayuki; Otsuji, Hideaki; Mizuno, Chiemi; Obata, Hirozumi; Park, Hyohun; Nakajo, Shinobu; Okanoue, Takeshi
2005-09-01
The aim of this study was to assess and compare the sensitivity of power Doppler sonography, contrast-enhanced sonography, plain computed tomography (CT), and dynamic magnetic resonance imaging (MRI) for detecting hepatocellular carcinoma (HCC) nodules incompletely treated with transcatheter arterial embolization (TAE). A total of 63 unresectable HCC nodules were examined in this study. The HCCs were treated with TAE. All patients underwent plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI 1 week after TAE. The sensitivity of each modality to incompletely treated HCC nodules was compared. Detection of the residual viable HCC on angiography or tumor biopsy was regarded as the gold standard for the diagnosis of incomplete treatment. Twenty-four nodules (38%) were diagnosed as incompletely treated. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these incompletely treated nodules were 42% (10/24), 46% (11/24), 88% (21/24), and 79% (19/24), respectively. Eighty percent (19 nodules) of the 24 incompletely treated nodules were located within a depth of less than 8 cm. The sensitivities of plain CT, power Doppler sonography, contrast-enhanced harmonic power Doppler sonography, and dynamic MRI to these superficial incompletely treated nodules were 37% (7/19), 53% (10/19), 100% (19/19), and 74% (14/19), respectively. In contrast, the sensitivities of each modality to deeply located nodules were 60% (3/5), 20% (1/5), 40% (2/5), and 100% (5/5), respectively. Plain CT and power Doppler sonography had a low sensitivity to HCC nodules incompletely treated with TAE. Except for those that were deeply located, contrast-enhanced harmonic sonography showed the highest sensitivity in detecting incompletely treated HCC nodules.
Three-dimensional power Doppler sonography in screening for carotid artery disease.
Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D
2000-01-01
Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.
Lei, M H; Chen, J J; Ko, Y L; Cheng, J J; Kuan, P; Lien, W P
1995-01-01
This study assessed the usefulness of continuous wave Doppler echocardiography and color flow mapping in evaluating pulmonary regurgitation (PR) and estimating pulmonary artery (PA) pressure. Forty-three patients were examined, and high quality Doppler spectral recordings of PR were obtained in 32. All patients underwent cardiac catheterization, and simultaneous PA and right ventricular (RV) pressures were recorded in 17. Four Doppler regurgitant flow velocity patterns were observed: pandiastolic plateau, biphasic, peak and plateau, and early diastolic triangular types. The peak diastolic and end-diastolic PA-to-RV pressure gradients derived from the Doppler flow profiles correlated well with the catheter measurements (r = 0.95 and r = 0.95, respectively). As PA pressure increased, the PR flow velocity became higher; a linear relationship between either systolic or mean PA pressure and Doppler-derived peak diastolic pressure gradient was noted (r = 0.90 and 0.94, respectively). Based on peak diastolic gradients of < 15, 15-30 or > 30 mm Hg, patients could be separated as those with mild, moderate or severe pulmonary hypertension, respectively (p < 0.05). A correlation was also observed between PA diastolic pressure and Doppler-derived end-diastolic pressure gradient (r = 0.91). Moreover, the Doppler velocity decay slope of PR closely correlated with that derived from the catheter method (r = 0.98). The decay slope tended to be steeper with the increment in regurgitant jet area and length obtained from color flow mapping. In conclusion, continuous wave Doppler evaluation of PR is a useful means for noninvasive estimation of PA pressure, and the Doppler velocity decay slope seems to reflect the severity of PR.
Spread-Spectrum Beamforming and Clutter Filtering for Plane-Wave Color Doppler Imaging.
Mansour, Omar; Poepping, Tamie L; Lacefield, James C
2016-07-21
Plane-wave imaging is desirable for its ability to achieve high frame rates, allowing the capture of fast dynamic events and continuous Doppler data. In most implementations of plane-wave imaging, multiple low-resolution images from different plane wave tilt angles are compounded to form a single high-resolution image, thereby reducing the frame rate. Compounding improves the lateral beam profile in the high-resolution image, but it also acts as a low-pass filter in slow time that causes attenuation and aliasing of signals with high Doppler shifts. This paper introduces a spread-spectrum color Doppler imaging method that produces high-resolution images without the use of compounding, thereby eliminating the tradeoff between beam quality, maximum unaliased Doppler frequency, and frame rate. The method uses a long, random sequence of transmit angles rather than a linear sweep of plane wave directions. The random angle sequence randomizes the phase of off-focus (clutter) signals, thereby spreading the clutter power in the Doppler spectrum, while keeping the spectrum of the in-focus signal intact. The ensemble of randomly tilted low-resolution frames also acts as the Doppler ensemble, so it can be much longer than a conventional linear sweep, thereby improving beam formation while also making the slow-time Doppler sampling frequency equal to the pulse repetition frequency. Experiments performed using a carotid artery phantom with constant flow demonstrate that the spread-spectrum method more accurately measures the parabolic flow profile of the vessel and outperforms conventional plane-wave Doppler in both contrast resolution and estimation of high flow velocities. The spread-spectrum method is expected to be valuable for Doppler applications that require measurement of high velocities at high frame rates.
Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun
2018-03-12
This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.
One way Doppler extractor. Volume 1: Vernier technique
NASA Technical Reports Server (NTRS)
Blasco, R. W.; Klein, S.; Nossen, E. J.; Starner, E. R.; Yanosov, J. A.
1974-01-01
A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.
Cournane, S; Fagan, A J; Browne, J E
2014-05-01
Results from a four-year audit of a Doppler quality assurance (QA) program using a commercially available Doppler string phantom are presented. The suitability of the phantom was firstly determined and modifications were made to improve the reliability and quality of the measurements. QA of Doppler ultrasound equipment is very important as data obtained from these systems is used in patient management. It was found that if the braided-silk filament of the Doppler phantom was exchanged with an O-ring rubber filament and the velocity range below 50 cm/s was avoided for Doppler quality control (QC) measurements, then the maximum velocity accuracy (MVA) error and intrinsic spectral broadening (ISB) results obtained using this device had a repeatability of 18 ± 3.3% and 19 ± 3.5%, respectively. A consistent overestimation of the MVA of between 12% and 56% was found for each of the tested ultrasound systems. Of more concern was the variation of the overestimation within each respective transducer category: MVA errors of the linear, curvilinear and phased array probes were in the range 12.3-20.8%, 32.3-53.8% and 27-40.7%, respectively. There is a dearth of QA data for Doppler ultrasound; it would be beneficial if a multicentre longitudinal study was carried out using the same Doppler ultrasound test object to evaluate sensitivity to deterioration in performance measurements. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Boonman, Arjan M.; Parsons, Stuart; Jones, Gareth
2003-01-01
Many species of bat use ultrasonic frequency modulated (FM) pulses to measure the distance to objects by timing the emission and reception of each pulse. Echolocation is mainly used in flight. Since the flight speed of bats often exceeds 1% of the speed of sound, Doppler effects will lead to compression of the time between emission and reception as well as an elevation of the echo frequencies, resulting in a distortion of the perceived range. This paper describes the consequences of these Doppler effects on the ranging performance of bats using different pulse designs. The consequences of Doppler effects on ranging performance described in this paper assume bats to have a very accurate ranging resolution, which is feasible with a filterbank receiver. By modeling two receiver types, it was first established that the effects of Doppler compression are virtually independent of the receiver type. Then, used a cross-correlation model was used to investigate the effect of flight speed on Doppler tolerance and range-Doppler coupling separately. This paper further shows how pulse duration, bandwidth, function type, and harmonics influence Doppler tolerance and range-Doppler coupling. The influence of each signal parameter is illustrated using calls of several bat species. It is argued that range-Doppler coupling is a significant source of error in bat echolocation, and various strategies bats could employ to deal with this problem, including the use of range rate information are discussed.
NASA Technical Reports Server (NTRS)
Folkner, W. M.; Border, J. S.; Nandi, S.; Zukor, K. S.
1993-01-01
A new radio metric positioning technique has demonstrated improved orbit determination accuracy for the Magellan and Pioneer Venus Orbiter orbiters. The new technique, known as Same-Beam Interferometry (SBI), is applicable to the positioning of multiple planetary rovers, landers, and orbiters which may simultaneously be observed in the same beamwidth of Earth-based radio antennas. Measurements of carrier phase are differenced between spacecraft and between receiving stations to determine the plane-of-sky components of the separation vector(s) between the spacecraft. The SBI measurements complement the information contained in line-of-sight Doppler measurements, leading to improved orbit determination accuracy. Orbit determination solutions have been obtained for a number of 48-hour data arcs using combinations of Doppler, differenced-Doppler, and SBI data acquired in the spring of 1991. Orbit determination accuracy is assessed by comparing orbit solutions from adjacent data arcs. The orbit solution differences are shown to agree with expected orbit determination uncertainties. The results from this demonstration show that the orbit determination accuracy for Magellan obtained by using Doppler plus SBI data is better than the accuracy achieved using Doppler plus differenced-Doppler by a factor of four and better than the accuracy achieved using only Doppler by a factor of eighteen. The orbit determination accuracy for Pioneer Venus Orbiter using Doppler plus SBI data is better than the accuracy using only Doppler data by 30 percent.
MicroV Technology to Improve Transcranial Color Coded Doppler Examinations.
Malferrari, Giovanni; Pulito, Giuseppe; Pizzini, Attilia Maria; Carraro, Nicola; Meneghetti, Giorgio; Sanzaro, Enzo; Prati, Patrizio; Siniscalchi, Antonio; Monaco, Daniela
2018-05-04
The purpose of this review is to provide an update on technology related to Transcranial Color Coded Doppler Examinations. Microvascularization (MicroV) is an emerging Power Doppler technology which can allow visualization of low and weak blood flows even at high depths, thus providing a suitable technique for transcranial ultrasound analysis. With MicroV, reconstruction of the vessel shape can be improved, without any overestimation. Furthermore, by analyzing the Doppler signal, MicroV allows a global image of the Circle of Willis. Transcranial Doppler was originally developed for the velocimetric analysis of intracranial vessels, in particular to detect stenoses and the assessment of collateral circulation. Doppler velocimetric analysis was then compared to other neuroimaging techniques, thus providing a cut-off threshold. Transcranial Color Coded Doppler sonography allowed the characterization of vessel morphology. In both Color Doppler and Power Doppler, the signal overestimated the shape of the intracranial vessels, mostly in the presence of thin vessels and high depths of study. In further neurosonology technology development efforts, attempts have been made to address morphology issues and overcome technical limitations. The use of contrast agents has helped in this regard by introducing harmonics and subtraction software, which allowed better morphological studies of vessels, due to their increased signal-to-noise ratio. Having no limitations in the learning curve, in time and contrast agent techniques, and due to its high signal-to-noise ratio, MicroV has shown great potential to obtain the best morphological definition. Copyright © 2018 by the American Society of Neuroimaging.
Laser Doppler diagnostics for orthodontia
NASA Astrophysics Data System (ADS)
Ryzhkova, Anastasia V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Ulyanov, Sergey S.; Lepilin, Alexander V.; Kharish, Natalia A.
2004-06-01
The results of statistical analysis of Doppler spectra of intensity fluctuations of light, scattered from mucous membrane of oral cavity of healthy volunteers and patients, abused by the orthodontic diseases, are presented. Analysis of Doppler spectra, obtained from tooth pulp of patients, is carried out. New approach to monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of Doppler measuring system on formation of the output signal is studied.
Staggered Multiple-PRF Ultrafast Color Doppler.
Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien
2016-06-01
Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.
Fukuda, Hiroyuki; Numata, Kazushi; Nozaki, Akito; Kondo, Masaaki; Morimoto, Manabu; Maeda, Shin; Tanaka, Katsuaki; Ohto, Masao; Ito, Ryu; Ishibashi, Yoshiharu; Oshima, Noriyoshi; Ito, Ayao; Zhu, Hui; Wang, Zhi-Biao
2013-12-01
We evaluated the usefulness of color Doppler flow imaging to compensate for the inadequate resolution of the ultrasound (US) monitoring during high-intensity focused ultrasound (HIFU) for the treatment of hepatocellular carcinoma (HCC). US-guided HIFU ablation assisted using color Doppler flow imaging was performed in 11 patients with small HCC (<3 lesions, <3 cm in diameter). The HIFU system (Chongqing Haifu Tech) was used under US guidance. Color Doppler sonographic studies were performed using an HIFU 6150S US imaging unit system and a 2.7-MHz electronic convex probe. The color Doppler images were used because of the influence of multi-reflections and the emergence of hyperecho. In 1 of the 11 patients, multi-reflections were responsible for the poor visualization of the tumor. In 10 cases, the tumor was poorly visualized because of the emergence of a hyperecho. In these cases, the ability to identify the original tumor location on the monitor by referencing the color Doppler images of the portal vein and the hepatic vein was very useful. HIFU treatments were successfully performed in all 11 patients with the assistance of color Doppler imaging. Color Doppler imaging is useful for the treatment of HCC using HIFU, compensating for the occasionally poor visualization provided by B-mode conventional US imaging.
Gilio, Daniel Bruno; Miranda Corrêa, Rosana Rosa; Souza de Oliveira Guimarães, Camila; Peres, Luiz Cesar; Marques Salge, Ana Karina; Cavellani, Camila Lourencini; de Paula Antunes Teixeira, Vicente; Costa da Cunha Castro, Eumenia
2009-08-01
One of the frequent questions in obstetric practice is to determine placental vascular changes that may account for abnormal Doppler flow velocity alterations in maternal uterine vessels from women and fetuses without pregnancy pathology. A retrospective morphometric study was realized using 27 placentas from patients submitted for Doppler flow velocity exam during pregnancy. The placentas were morphologically examined using hematoxylin-eosin staining. Measurements of villi were made with the use of a video camera coupled to a common light microscope and a computer with automatic image analyzing software. Of the 27 placentas, 13 (48%) were of patients showing unaltered Doppler and 14 (52%) showing altered Doppler. The number of stem villi vessels was significantly larger in the placentas of patients with Doppler exam alterations (P = 0.003). This group also presented greater stem villi vessel thickness, although without significant difference. The number of intermediary and terminal villi vessels was greater in the placentas of patients with altered Doppler exams (P < 0.001), and a greater terminal villi area was observed in these cases (P < 0.001). The morphological proof that uterine artery Doppler flow velocity exam alterations are associated with placental vascular alterations demonstrates the importance of this exam during prenatal care, even in the absence of maternal-fetal alterations.
NASA Technical Reports Server (NTRS)
Bluestein, H. B.; Doviak, R. J.; Eilts, M. D.; Mccaul, E. W.; Rabin, R.; Sundara-Rajan, A.; Zrnic, D. S.
1986-01-01
The first experiment to combine airborne Doppler Lidar and ground-based dual Doppler Radar measurements of wind to detail the lower tropospheric flows in quiescent and stormy weather was conducted in central Oklahoma during four days in June-July 1981. Data from these unique remote sensing instruments, coupled with data from conventional in-situ facilities, i.e., 500-m meteorological tower, rawinsonde, and surface based sensors, were analyzed to enhance understanding of wind, waves and turbulence. The purposes of the study were to: (1) compare winds mapped by ground-based dual Doppler radars, airborne Doppler lidar, and anemometers on a tower; (2) compare measured atmospheric boundary layer flow with flows predicted by theoretical models; (3) investigate the kinematic structure of air mass boundaries that precede the development of severe storms; and (4) study the kinematic structure of thunderstorm phenomena (downdrafts, gust fronts, etc.) that produce wind shear and turbulence hazardous to aircraft operations. The report consists of three parts: Part 1, Intercomparison of Wind Data from Airborne Lidar, Ground-Based Radars and Instrumented 444 m Tower; Part 2, The Structure of the Convective Atmospheric Boundary Layer as Revealed by Lidar and Doppler Radars; and Part 3, Doppler Lidar Observations in Thunderstorm Environments.
NASA Technical Reports Server (NTRS)
Bilbro, J. W.; Vaughan, W. W.
1980-01-01
Coherent Doppler lidar appears to hold great promise in contributing to the basic store of knowledge concerning flow field characteristics in the nonprecipitous regions surrounding severe storms. The Doppler lidar, through its ability to measure clear air returns, augments the conventional Doppler radar system, which is most useful in the precipitous regions of the storm. A brief description of the Doppler lidar severe storm measurement system is provided along with the technique to be used in performing the flow field measurements. The application of the lidar is addressed, and the planned measurement program is outlined.
Eyeballing oscillators for pulsed Doppler radar
NASA Astrophysics Data System (ADS)
Goldman, S.
1985-03-01
The visibility of small targets to a Doppler radar system in the presence of large targets is limited by phase noise. Such limitations occur when an airborne radar searches the ground for a mobile vehicle. Under these conditions, the performance of the Doppler radar depends greatly on the specifications of its phased-locked oscillator. Goldman (1984) has discussed the steps required to evaluate the noise resulting from a pulsed Doppler radar system. In the present investigation, these techniques are applied in reverse to determine system specifications for oscillator noise. A 95-GHz pulsed Doppler radar system is used as an example of specifying system phase noise.
NASA Technical Reports Server (NTRS)
Winn, F. B.; Reinbold, S. R.; Yip, K. W.; Koch, R. E.; Lubeley, A.
1975-01-01
Doppler data from Mariner 6, 7, 9, and 10 and Pioneer 10 and 11 were discussed and the rms noise level for various sun-earth-probe angles were shown. The noise levels of both S- and X-band Doppler data for sun-earth-probe angles smaller than 20 deg were observed to be orders of magnitude greater than nominal. Such solar plasma-related Doppler degradation reduced the Mariner 10-Mercury 11 encounter navigation accuracy by nearly a factor of 10. Furthermore, this degradation was shown to be indirectly related to plasma dynamics and not a direct measure of the dynamics.
Dual-Doppler Feasibility Study
NASA Technical Reports Server (NTRS)
Huddleston, Lisa L.
2012-01-01
When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any radar geometry issues at the NWS MLB radar, such as the "cone of silence" or beam blockage. In the event of a radar outage at one of the sites, the multi-radar algorithms would provide continuing coverage of the area through use of the data from the remaining operational radar sites. There are several options to collect, edit, synthesize and display dual-Doppler data sets. These options include commercial packages available for purchase and a variety of freeware packages available from the National Center for Atmospheric Research (NCAR) for processing raw radar data. However, evaluation of the freeware packages revealed that they do not have sufficient documentation and configuration control to be certified for 45 SW use. Additionally, a TI data line must be installed/leased from the NWS MLB office and CCAFS to enable the receipt of NWS MLB raw radar data to use in the dual-Doppler synthesis. Integration of the TI data line into the Eastern Range infrastructure that will meet the security requirements necessary for 45 SW use is time-consuming and costly. Overall evaluation indicates that establishment of the dual-Doppler capability using the existing operational radar systems is desirable and feasible with no technical concerns. Installation of such a system represents a significant enhancement to forecasting capabilities at the 45 WS and at NWS MLB. However, data security and cost considerations must be evaluated in light of current budgetary constraints. In any case, gaining the dual-Doppler capability will provide opportunities for better visualization of the wind field and better forecasting of the onset of convection and severe weather events to support space launch operations at KSC and CCAFS.
Laser Doppler Velocimetry Workshop
NASA Technical Reports Server (NTRS)
Owen, R. B.
1979-01-01
The potential of laser Doppler velocimetry as a technique for use in mapping flows in the several fluid systems under development for doing research on low-gravity processes, is investigated. Laser Doppler velocimetry techniques, equipment, and applications are summarized.
Dolcetti, Giulio; Krynkin, Anton
2017-11-01
Experimental data are presented on the Doppler spectra of airborne ultrasound forward scattered by the rough dynamic surface of an open channel turbulent flow. The data are numerically interpreted based on a Kirchhoff approximation for a stationary random water surface roughness. The results show a clear link between the Doppler spectra and the characteristic spatial and temporal scales of the water surface. The decay of the Doppler spectra is proportional to the velocity of the flow near the surface. At higher Doppler frequencies the measurements show a less steep decrease of the Doppler spectra with the frequency compared to the numerical simulations. A semi-empirical equation for the spectrum of the surface elevation in open channel turbulent flows over a rough bed is provided. The results of this study suggest that the dynamic surface of open channel turbulent flows can be characterized remotely based on the Doppler spectra of forward scattered airborne ultrasound. The method does not require any equipment to be submerged in the flow and works remotely with a very high signal to noise ratio.
NASA Astrophysics Data System (ADS)
Raccanelli, Alvise; Bertacca, Daniele; Jeong, Donghui; Neyrinck, Mark C.; Szalay, Alexander S.
2018-03-01
We study the parity-odd part (that we shall call Doppler term) of the linear galaxy two-point correlation function that arises from wide-angle, velocity, Doppler lensing and cosmic acceleration effects. As it is important at low redshift and at large angular separations, the Doppler term is usually neglected in the current generation of galaxy surveys. For future wide-angle galaxy surveys, however, we show that the Doppler term must be included. The effect of these terms is dominated by the magnification due to relativistic aberration effects and the slope of the galaxy redshift distribution and it generally mimics the effect of the local type primordial non-Gaussianity with the effective nonlinearity parameter fNLeff of a few; we show that this would affect forecasts on measurements of fNL at low-redshift. Our results show that a survey at low redshift with large number density over a wide area of the sky could detect the Doppler term with a signal-to-noise ratio of ∼ 1 - 20, depending on survey specifications.
Liu, Fang; Shen, Changqing; He, Qingbo; Zhang, Ao; Liu, Yongbin; Kong, Fanrang
2014-01-01
A fault diagnosis strategy based on the wayside acoustic monitoring technique is investigated for locomotive bearing fault diagnosis. Inspired by the transient modeling analysis method based on correlation filtering analysis, a so-called Parametric-Mother-Doppler-Wavelet (PMDW) is constructed with six parameters, including a center characteristic frequency and five kinematic model parameters. A Doppler effect eliminator containing a PMDW generator, a correlation filtering analysis module, and a signal resampler is invented to eliminate the Doppler effect embedded in the acoustic signal of the recorded bearing. Through the Doppler effect eliminator, the five kinematic model parameters can be identified based on the signal itself. Then, the signal resampler is applied to eliminate the Doppler effect using the identified parameters. With the ability to detect early bearing faults, the transient model analysis method is employed to detect localized bearing faults after the embedded Doppler effect is eliminated. The effectiveness of the proposed fault diagnosis strategy is verified via simulation studies and applications to diagnose locomotive roller bearing defects. PMID:24803197
Right Ventricular Tissue Doppler in Space Flight
NASA Technical Reports Server (NTRS)
Garcia, Kathleen M.; Hamilton, Douglas R.; Sargsyan, Ashot E.; Ebert, Douglas; Martin, David S.; Barratt, Michael R.; Martin, David S.; Bogomolov, Valery V.; Dulchavsky, Scott A.; Duncan, J. Michael
2010-01-01
The presentation slides review normal physiology of the right ventricle in space, general physiology of the right ventricle; difficulties in imaging the heart in space, imaging methods, tissue Doppler spectrum, right ventricle tissue Doppler, and Rt Tei Index.
Applications of Doppler ultrasound in clinical vascular disease
NASA Technical Reports Server (NTRS)
Barnes, R. W.; Hokanson, D. E.; Sumner, D. S.; Strandness, D. E., Jr.
1975-01-01
Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.
Wavelet analysis of the Laser Doppler signal to assess skin perfusion.
Bagno, Andrea; Martini, Romeo
2015-01-01
The hemodynamics of skin microcirculation can be clinically assessed by means of Laser Doppler Fluxmetry. Laser Doppler signals show periodic oscillations because of fluctuations of microvascular perfusion (flowmotion), which are sustained by contractions and relaxations of arteriolar walls rhythmically changing vessels diameter (vasomotion). The wavelet analysis applied to Laser Doppler signals displays six characteristic frequency intervals, from 0.005 to 2 Hz. Each interval is assigned to a specific structure of the cardiovascular system: heart, respiration, vascular myocites, sympathetic terminations, and endothelial cells (dependent and independent on nitric oxide). Therefore, mechanisms of skin perfusion can be investigated through wavelet analysis. In the present work, examples of methods and results of wavelet analysis applied to Laser Doppler signals are reported. Laser Doppler signals were acquired in two groups of patients to check possible changes in vascular activities, before and after occlusive reactive hyperaemia, and before and after revascularization.
Inverse Doppler Effects in Broadband Acoustic Metamaterials
Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.
2016-01-01
The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe. PMID:27578317
NASA Astrophysics Data System (ADS)
Tavakoli, Vahid; Stoddard, Marcus F.; Amini, Amir A.
2013-03-01
Quantitative motion analysis of echocardiographic images helps clinicians with the diagnosis and therapy of patients suffering from cardiac disease. Quantitative analysis is usually based on TDI (Tissue Doppler Imaging) or speckle tracking. These methods are based on two independent techniques - the Doppler Effect and image registration, respectively. In order to increase the accuracy of the speckle tracking technique and cope with the angle dependency of TDI, herein, a combined approach dubbed TDIOF (Tissue Doppler Imaging Optical Flow) is proposed. TDIOF is formulated based on the combination of B-mode and Doppler energy terms in an optical flow framework and minimized using algebraic equations. In this paper, we report on validations with simulated, physical cardiac phantom, and in-vivo patient data. It is shown that the additional Doppler term is able to increase the accuracy of speckle tracking, the basis for several commercially available echocardiography analysis techniques.
Inverse Doppler Effects in Broadband Acoustic Metamaterials
NASA Astrophysics Data System (ADS)
Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.
2016-08-01
The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.
Miura, Masahiro; Hong, Young-Joo; Yasuno, Yoshiaki; Muramatsu, Daisuke; Iwasaki, Takuya; Goto, Hiroshi
2015-03-01
To evaluate the 3-dimensional architecture of neovascularization in proliferative diabetic retinopathy using Doppler optical coherence tomography (OCT). Prospective, nonrandomized clinical trial. Seventeen eyes of 14 patients with proliferative diabetic retinopathy were prospectively studied. Prototype Doppler OCT was used to evaluate the 3-dimensional vascular architecture at vitreoretinal adhesions. Proliferative membranes were detected in all eyes with proliferative diabetic retinopathy by standard OCT images. Doppler OCT images detected blood flow by neovascularization of the disc in 12 eyes and neovascularization elsewhere in 11 eyes. Doppler OCT images showed the 3-dimensional extent of new vessels at various stages of neovascularization, and the extent of new vessels could be clearly confirmed at vitreoretinal adhesions. Doppler OCT is useful for the detection and evaluation of the 3-dimensional vascular structure of neovascularization, and can assist in the noninvasive assessment of proliferative diabetic retinopathy. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
An airport wind shear detection and warning system using Doppler radar: A feasibility study
NASA Technical Reports Server (NTRS)
Mccarthy, J.; Blick, E. F.; Elmore, K. L.
1981-01-01
A feasibility study was conducted to determine whether ground based Doppler radar could measure the wind along the path of an approaching aircraft with sufficient accuracy to predict aircraft performance. Forty-three PAR approaches were conducted, with 16 examined in detail. In each, Doppler derived longitudinal winds were compared to aircraft measured winds; in approximately 75 percent of the cases, the Doppler and aircraft winds were in acceptable agreement. In the remaining cases, errors may have been due to a lack of Doppler resolution, a lack of co-location of the two sampling volumes, the presence of eddy or vortex like disturbances within the pulse volume, or the presence of point targets in antenna side lobes. It was further concluded that shrouding techniques would have reduced the side lobe problem. A ground based Doppler radar operating in the optically clear air, provides the appropriate longitudinal winds along an aircraft's intended flight path.
Efficient geometric rectification techniques for spectral analysis algorithm
NASA Technical Reports Server (NTRS)
Chang, C. Y.; Pang, S. S.; Curlander, J. C.
1992-01-01
The spectral analysis algorithm is a viable technique for processing synthetic aperture radar (SAR) data in near real time throughput rates by trading the image resolution. One major challenge of the spectral analysis algorithm is that the output image, often referred to as the range-Doppler image, is represented in the iso-range and iso-Doppler lines, a curved grid format. This phenomenon is known to be the fanshape effect. Therefore, resampling is required to convert the range-Doppler image into a rectangular grid format before the individual images can be overlaid together to form seamless multi-look strip imagery. An efficient algorithm for geometric rectification of the range-Doppler image is presented. The proposed algorithm, realized in two one-dimensional resampling steps, takes into consideration the fanshape phenomenon of the range-Doppler image as well as the high squint angle and updates of the cross-track and along-track Doppler parameters. No ground reference points are required.
Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H
2010-02-01
Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.
Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H
2006-12-01
To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (p<0.01) and 0.328 (p<0.05), respectively. The ultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.
Doppler ultrasound monitoring technology.
Docker, M F
1993-03-01
Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.