Science.gov

Sample records for doppler transcraniano para

  1. Doppler and the Doppler Effect.

    DTIC Science & Technology

    1984-06-01

    Doppler Applications Doppler Effect Roemer Doppler Principle Bradley Relative motion Velocity History Light Velocity 20. ABSTRACT (Continue on reverse...of Colorado, Boulder, CO 11-14 Jan 1984 5 1. Historical Background The astronomer Olaf Roemer determined the velocity of light in 1676 from time...approached Jupiter and longer when it receded from Jupiter. In effect, Roemer used a Doppler method in determining the velocity of light . [2 ] In 1727

  2. Doppler echocardiography

    SciTech Connect

    Labovitz, A.J.; Williams, G.A.

    1988-01-01

    The authors are successful in presenting a basic book on clinical quantitative Doppler echocardiography. It is not intended to be a comprehensive text, but it does cover clinical applications in a succinct fashion. Only the more common diseases in the adult are considered. The subjects are presented logically and are easy to comprehend. The illustrations are good, and the book is paperbound. The basic principles of Doppler echocardiography are presented briefly. The book ends with chapters on left ventricular function (stroke volume and cardiac output), congenital heart disease, and color Doppler echo-cardiography. There are numerous references and a good glossary and index.

  3. Doppler flowmeter

    DOEpatents

    Karplus, Henry H. B.; Raptis, Apostolos C.

    1983-01-01

    A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.

  4. Doppler flowmeter

    DOEpatents

    Karplus, H.H.B.; Raptis, A.C.

    1981-11-13

    A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.

  5. DOPPLER WEATHER SYSTEM

    SciTech Connect

    Berlin, Gary J.

    2002-08-05

    The SRS Doppler Weather System consists of a Doppler Server, A Master Server (also known as the Weather Server), several Doppler Slave Servers, and client-side software program called the Doppler Radar Client. This system is used to display near rel-time images taken from the SRS Weather Center's Doppler Radar computer. The Doppler Server is software that resides on the SRS Doppler Computer. It gathers raw data, 24-bit color weather images via screen scraping ever five minutes as requested by the Master Server. The Doppler Server then reduces the 24-bit color images to 8-bit color using a fixed color table for analysis and compression. This preserves the fidelity of the image color and arranges the colors in specific order for display. At the time of color reduction, the white color used for the city names on the background images are remapped to a different index (color) of white that the white on the weather scale. The Weather Server places a time stamp on the image, then compresses the image and passes it to all Doppler Slave servers. Each of the Doppler Slave servers mainitain a circular buffer of the eight most current images representing the last 40 minutes of weather data. As a new image is added, the oldest drops off. The Doppler Radar Client is an optional install program for any site-wide workstation. When a Client session is started, the Client requests Doppler Slave server assignment from the Master Server. Upon its initial request to the Slave Server, the Client obtains all eight current images and maintains its own circular buffer, updating its images every five minutes as the Doppler Slave is updated. Three background reference images are stored as part of the Client. The Client brings up the appropriate background image, decompresses the doppler data, and displays the doppler data on the background image.

  6. Christian Doppler and the Doppler effect

    NASA Astrophysics Data System (ADS)

    Toman, Kurt

    1984-04-01

    A summary is given of Doppler's life and career. He was born 180 years ago on November 29, 1803, in Salzburg, Austria. He died on March 17, 1853 in Venice. The effect bearing his name was first announced in a presentation before the Royal Bohemian Society of the Sciences in Prague on May 25, 1842. Doppler considered his work a generalization of the aberration theorem as discovered by Bradley. With it came the inference that the perception of physical phenomena can change with the state of motion of the observer. Acceptance of the principle was not without controversy. In 1852, the mathematician Petzval claimed that no useful scientific deductions can be made from Doppler's elementary equations. In 1860, Ernst Mach resolved the misunderstanding that clouded this controversy. The Doppler effect is alive and well. Its role in radio science and related disciplines is enumerated.

  7. Doppler flowmetry in preeclampsia.

    PubMed

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  8. Advances in Doppler OCT

    PubMed Central

    Liu, Gangjun; Chen, Zhongping

    2014-01-01

    We review the principle and some recent applications of Doppler optical coherence tomography (OCT). The advances of the phase-resolved Doppler OCT method are described. Functional OCT algorithms which are based on an extension of the phase-resolved scheme are also introduced. Recent applications of Doppler OCT for quantification of flow, imaging of microvasculature and vocal fold vibration, and optical coherence elastography are briefly discussed. PMID:24443649

  9. Advanced Doppler tracking experiments

    NASA Technical Reports Server (NTRS)

    Armstrong, J. W.

    1989-01-01

    The Doppler tracking method is currently the only technique available for broadband gravitational wave searches in the approx. 10(exp -4) to 10(exp -1) Hz low frequency band. A brief review is given of the Doppler method, a discussion of the main noise sources, and a review of experience with current spacecraft and the prospects for sensitivity improvements in an advanced Doppler tracking experiment.

  10. The Cognitive Doppler.

    ERIC Educational Resources Information Center

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  11. Doppler ultrasound monitoring technology.

    PubMed

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  12. The Cognitive Doppler.

    ERIC Educational Resources Information Center

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  13. Joint Agency Doppler Technology Tests.

    DTIC Science & Technology

    DOPPLER RADAR, *METEOROLOGICAL RADAR, *EARLY WARNING SYSTEMS, DAMAGE, HAZARDS, NETWORKS, REAL TIME, RADAR, IDENTIFICATION, RELIABILITY, HAIL, AIR FORCE FACILITIES, DOPPLER SYSTEMS, AIRPORTS, WARNING SYSTEMS, TORNADOES .

  14. Doppler radar flowmeter

    DOEpatents

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  15. Doppler Lidar (DL) Handbook

    SciTech Connect

    Newsom, RK

    2012-02-13

    The Doppler lidar (DL) is an active remote sensing instrument that provides range- and time-resolved measurements of radial velocity and attenuated backscatter. The principle of operation is similar to radar in that pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is inferred. The radial or line-of-sight velocity of the scatterers is determined from the Doppler frequency shift of the backscattered radiation. The DL uses a heterodyne detection technique in which the return signal is mixed with a reference laser beam (i.e., local oscillator) of known frequency. An onboard signal processing computer then determines the Doppler frequency shift from the spectra of the heterodyne signal. The energy content of the Doppler spectra can also be used to determine attenuated backscatter.

  16. Pulse subtraction Doppler

    NASA Astrophysics Data System (ADS)

    Mahue, Veronique; Mari, Jean Martial; Eckersley, Robert J.; Caro, Colin G.; Tang, Meng-Xing

    2010-01-01

    Recent advances have demonstrated the feasibility of molecular imaging using targeted microbubbles and ultrasound. One technical challenge is to selectively detect attached bubbles from those freely flowing bubbles and surrounding tissue. Pulse Inversion Doppler is an imaging technique enabling the selective detection of both static and moving ultrasound contrast agents: linear scatterers generate a single band Doppler spectrum, while non-linear scatterers generate a double band spectrum, one being uniquely correlated with the presence of contrast agents and non-linear tissue signals. We demonstrate that similar spectrums, and thus the same discrimination, can be obtained through a Doppler implementation of Pulse Subtraction. This is achieved by reconstructing a virtual echo using the echo generated from a short pulse transmission. Moreover by subtracting from this virtual echo the one generated from a longer pulse transmission, it is possible to fully suppress the echo from linear scatterers, while for non-linear scatterers, a signal will remain, allowing classical agent detection. Simulations of a single moving microbubble and a moving linear scatterer subject to these pulses show that when the virtual echo and the long pulse echo are used to perform pulsed Doppler, the power Doppler spectrum allows separation of linear and non-linear moving scattering. Similar results are obtained on experimental data acquired on a flow containing either microbubble contrast agents or linear blood mimicking fluid. This new Doppler method constitutes an alternative to Pulse Inversion Doppler and preliminary results suggest that similar dual band spectrums could be obtained by the combination of any non-linear detection technique with Doppler demodulation.

  17. Penile Doppler ultrasonography revisited.

    PubMed

    Jung, Dae Chul; Park, Sung Yoon; Lee, Joo Yong

    2017-06-10

    Penile Doppler ultrasonography is a high-performing, noninvasive or minimally-invasive imaging modality that allows the depiction of the normal anatomy and macroscopic pathologic changes in real time. Moreover, functional changes in penile blood flow, as seen in erectile dysfunction (ED), can be analyzed using color Doppler ultrasonography (CDUS). This review article describes the normal sonographic anatomy of the penis, the sonographic technique for evaluating ED, the normal phases of erection, and the various causes of ED. Additionally, we describe the interpretation of different parameters and findings on penile CDUS for the diagnosis and classification of ED, priapism, and Peyronie disease.

  18. Doppler ion program description

    SciTech Connect

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities.

  19. The Doppler Pendulum Experiment

    ERIC Educational Resources Information Center

    Lee, C. K.; Wong, H. K.

    2011-01-01

    An experiment to verify the Doppler effect of sound waves is described. An ultrasonic source is mounted at the end of a simple pendulum. As the pendulum swings, the rapid change of frequency can be recorded by a stationary receiver using a simple frequency-to-voltage converter. The experimental results are in close agreement with the Doppler…

  20. The Doppler Pendulum Experiment

    ERIC Educational Resources Information Center

    Lee, C. K.; Wong, H. K.

    2011-01-01

    An experiment to verify the Doppler effect of sound waves is described. An ultrasonic source is mounted at the end of a simple pendulum. As the pendulum swings, the rapid change of frequency can be recorded by a stationary receiver using a simple frequency-to-voltage converter. The experimental results are in close agreement with the Doppler…

  1. Photonic doppler velocimetry

    SciTech Connect

    Lowry, M E; Molau, N E; Sargis, P D; Strand, O T; Sweider, D

    1999-01-01

    We are developing a novel fiber-optic approach to laser Doppler velocimetry as a diagnostic for high explosives tests. Using hardware that was originally developed for the telecommunications industry, we are able to measure surface velocities ranging from centimeters per second to kilometers per second. Laboratory measurements and field trials have shown excellent agreement with other diagnostics.

  2. Finnish Meteorological Institute Doppler Lidar

    SciTech Connect

    Ewan OConnor

    2015-03-27

    This doppler lidar system provides co-polar and cross polar attenuated backscatter coefficients,signal strength, and doppler velocities in the cloud and in the boundary level, including uncertainties for all parameters. Using the doppler beam swinging DBS technique, and Vertical Azimuthal Display (VAD) this system also provides vertical profiles of horizontal winds.

  3. Ultrasonic colour Doppler imaging

    PubMed Central

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been found to be of great value in assessing blood flow in many clinical conditions. Although the method for obtaining the velocity information is in many ways similar to the method for obtaining the anatomical information, it is technically more demanding for a number of reasons. It also has a number of weaknesses, perhaps the greatest being that in conventional systems, the velocities measured and thus displayed are the components of the flow velocity directly towards or away from the transducer, while ideally the method would give information about the magnitude and direction of the three-dimensional flow vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new techniques that seek to overcome the vector problem mentioned above are described. Finally, some examples of vector velocity images are presented. PMID:22866227

  4. Doppler effect in optical velocimetry

    NASA Astrophysics Data System (ADS)

    Rinkevichius, Bronius S.

    1996-02-01

    The current state of the optical metrology based on the Doppler effect has been reviewed. Some historical and scientific information is given, in addition the contemporary optical methods of the velocity measurement using the Doppler effect are analyzed. The Doppler effect applications in astrophysics, plasma physics, investigations of gas and liquid flows, acoustics, mechanics of the deforming solid body and of the rotational motion are considered. The description is presented for the following techniques of the velocity measurement: laser Doppler anemometry, laser Doppler vibrometry, laser gyroscopy.

  5. An airborne Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Dimarzio, C. A.

    1980-01-01

    A pulsed CO2 Doppler Lidar, developed for airborne measurements of atmospheric wind fields, is described. In-flight tests show that the device can be successfully utilized in the detection and measurement of mountain-wave turbulence and wind shear, and in the generation of time histories of wind-field variations in smooth flight. This Lidar is in the process of being configured for measurement of the atmospheric flow fields surrounding severe convective storms.

  6. Laser Doppler anemometry

    NASA Technical Reports Server (NTRS)

    Johnson, Dennis A.

    1988-01-01

    The material in this NASA TM is to appear as a chapter on Laser Doppler Anemometry (LDA) in the AGARDograph entitled, A Survey of Measurements and Measuring Techniques in Rapidly Distorted Compressible Turbulent Boundary Layers. The application of LDA (specifically, the dual-beam, burst-counter approach) to compressible flows is discussed. Subjects treated include signal processing, particle light scattering and tracking, data reduction and sampling bias, and three-dimensional measurements.

  7. Laser double Doppler flowmeter

    NASA Astrophysics Data System (ADS)

    Poffo, L.; Goujon, J.-M.; Le Page, R.; Lemaitre, J.; Guendouz, M.; Lorrain, N.; Bosc, D.

    2014-05-01

    The Laser Doppler flowmetry (LDF) is a non-invasive method for estimating the tissular blood flow and speed at a microscopic scale (microcirculation). It is used for medical research as well as for the diagnosis of diseases related to circulatory system tissues and organs including the issues of microvascular flow (perfusion). It is based on the Doppler effect, created by the interaction between the laser light and tissues. LDF measures the mean blood flow in a volume formed by the single laser beam, that penetrate into the skin. The size of this measurement volume is crucial and depends on skin absorption, and is not directly reachable. Therefore, current developments of the LDF are focused on the use of always more complex and sophisticated signal processing methods. On the other hand, laser Double Doppler Flowmeter (FL2D) proposes to use two laser beams to generate the measurement volume. This volume would be perfectly stable and localized at the intersection of the two laser beams. With FL2D we will be able to determine the absolute blood flow of a specific artery. One aimed application would be to help clinical physicians in health care units.

  8. Doppler Optical Coherence Tomography

    PubMed Central

    Leitgeb, Rainer A.; Werkmeister, René M.; Blatter, Cedric; Schmetterer, Leopold

    2014-01-01

    Optical Coherence Tomography (OCT) has revolutionized ophthalmology. Since its introduction in the early 1990s it has continuously improved in terms of speed, resolution and sensitivity. The technique has also seen a variety of extensions aiming to assess functional aspects of the tissue in addition to morphology. One of these approaches is Doppler OCT (DOCT), which aims to visualize and quantify blood flow. Such extensions were already implemented in time domain systems, but have gained importance with the introduction of Fourier domain OCT. Nowadays phase-sensitive detection techniques are most widely used to extract blood velocity and blood flow from tissues. A common problem with the technique is that the Doppler angle is not known and several approaches have been realized to obtain absolute velocity and flow data from the retina. Additional studies are required to elucidate which of these techniques is most promising. In the recent years, however, several groups have shown that data can be obtained with high validity and reproducibility. In addition, several groups have published values for total retinal blood flow. Another promising application relates to non-invasive angiography. As compared to standard techniques such as fluorescein and indocyanine-green angiography the technique offers two major advantages: no dye is required and depth resolution is required is provided. As such Doppler OCT has the potential to improve our abilities to diagnose and monitor ocular vascular diseases. PMID:24704352

  9. Clinical applications of doppler ultrasound

    SciTech Connect

    Taylor, K.J.W.; Burns, P.N.; Well, P.N.T.

    1987-01-01

    This book introduces a guide to the physical principles and instrumentation of duplex Doppler ultrasound and its applications in obstetrics, gynecology, neonatology, gastroentology, and evaluation of peripheral vascular disease. The book provides information needed to perform Doppler ultrasound examinations and interpret the results. An introduction to Doppler physics and instrumentation is followed by a thorough review of hemodynamics, which explains the principles underlying interpretation of Doppler signals. Of special note is the state-of-the-art coverage of new applications of Doppler in recognition of high-risk pregnancy, diagnosis of intrauterine growth retardation, investigation of neonatal blood flow, evaluation of first-trimester pregnancy, and diagnosis of gastrointestinal disease. The book also offers guidelines on the use of Doppler ultrasound in diagnosing carotid disease, deep venous thrombosis, and aorta/femoral disease.

  10. Laser Doppler diagnostics for orthodontia

    NASA Astrophysics Data System (ADS)

    Ryzhkova, Anastasia V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Ulyanov, Sergey S.; Lepilin, Alexander V.; Kharish, Natalia A.

    2004-06-01

    The results of statistical analysis of Doppler spectra of intensity fluctuations of light, scattered from mucous membrane of oral cavity of healthy volunteers and patients, abused by the orthodontic diseases, are presented. Analysis of Doppler spectra, obtained from tooth pulp of patients, is carried out. New approach to monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of Doppler measuring system on formation of the output signal is studied.

  11. Neutrino Induced Doppler Broadening

    PubMed Central

    Jolie, J.; Stritt, N.

    2000-01-01

    When a nucleus undergoes beta decay via the electron capture reaction, it emits an electron neutrino. The neutrino emission gives a small recoil to the atom, which can be experimentally observed as a Doppler broadening on subsequently emitted gamma rays. Using the two-axis flat-crystal spectrometer GAMS4 and the electron capture reaction in 152Eu, the motion of atoms having an excess kinetic energy of 3 eV in the solid state was studied. It is shown how the motion of the atom during the first hundreds of femtoseconds can be reconstructed. The relevance of this knowledge for a new neutrino helicity experiment is discussed. PMID:27551591

  12. Laser Doppler velocimetry primer

    NASA Technical Reports Server (NTRS)

    Bachalo, William D.

    1985-01-01

    Advanced research in experimental fluid dynamics required a familiarity with sophisticated measurement techniques. In some cases, the development and application of new techniques is required for difficult measurements. Optical methods and in particular, the laser Doppler velocimeter (LDV) are now recognized as the most reliable means for performing measurements in complex turbulent flows. And such, the experimental fluid dynamicist should be familiar with the principles of operation of the method and the details associated with its application. Thus, the goals of this primer are to efficiently transmit the basic concepts of the LDV method to potential users and to provide references that describe the specific areas in greater detail.

  13. ANL Doppler flowmeter

    NASA Astrophysics Data System (ADS)

    Karplus, H. B.; Raptis, A. C.; Lee, S.; Simpson, T.

    1985-10-01

    A flowmeter has been developed for measuring flow velocity in hot slurries. The flowmeter works on an ultrasonic Doppler principle in which ultrasound is injected into the flowing fluid through the solid pipe wall. Isolating waveguides separate the hot pipe from conventional ultrasonic transducers. Special clamp-on high-temperature transducers also can be adapted to work well in this application. Typical flows in pilot plants were found to be laminar, giving rise to broad-band Doppler spectra. A special circuit based on a servomechanism sensor was devised to determine the frequency average of such a broad spectrum. The device was tested at different pilot plants. Slurries with particulates greater than 70 microns (0.003 in.) yielded good signals, but slurries with extremely fine particulates were unpredictable. Small bubbles can replace the coarse particles to provide a good signal if there are not too many. Successful operation with very fine particulate slurries may have been enhanced by the presence of microbubbles.

  14. Doppler Beats or Interference Fringes?

    ERIC Educational Resources Information Center

    Kelly, Paul S.

    1979-01-01

    Discusses the following: another version of Doppler beats; alternate proof of spin-1 sin-1/2 problems; some mechanisms related to Dirac's strings; Doppler redshift in oblique approach of source and observer; undergraduate experiment on noise thermometry; use of the time evolution operator; resolution of an entropy maximization controversy;…

  15. Doppler Beats or Interference Fringes?

    ERIC Educational Resources Information Center

    Kelly, Paul S.

    1979-01-01

    Discusses the following: another version of Doppler beats; alternate proof of spin-1 sin-1/2 problems; some mechanisms related to Dirac's strings; Doppler redshift in oblique approach of source and observer; undergraduate experiment on noise thermometry; use of the time evolution operator; resolution of an entropy maximization controversy;…

  16. Digital Doppler measurement with spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Hinedi, Sami M.; Labelle, Remi C.; Bevan, Roland P.; Del Castillo, Hector M.; Chong, Dwayne C.

    1991-01-01

    Digital and analog phase-locked loop (PLL) receivers were operated in parallel, each tracking the residual carrier from a spacecraft. The PLL tracked the downlink carrier and measured its instantaneous phase. This information, combined with a knowledge of the uplink carrier and the transponder ratio, permitted the computation of a Doppler observable. In this way, two separate Doppler measurements were obtained for one observation window. The two receivers agreed on the magnitude of the Doppler effect to within 1 mHz. There was less jitter on the data from the digital receiver. This was due to its smaller noise bandwidth. The demonstration and its results are described.

  17. GEOS-3 Doppler difference tracking

    NASA Technical Reports Server (NTRS)

    Rosenbaum, B.

    1977-01-01

    The Doppler difference method as applied to track the GEOS 3 spacecraft is discussed. In this method a pair of 2 GHz ground tracking stations simultaneously track a spacecraft beacon to generate an observable signal in which bias and instability of the carrier frequency cancel. The baselines are formed by the tracking sites at Bermuda, Rosman, and Merritt Island. Measurements were made to evaluate the effectiveness of the Doppler differencing procedure in tracking a beacon target with the high dynamic rate of the GEOS 3 orbit. Results indicate the precision of the differenced data to be at a level comparable to the conventional precise two way Doppler tracking.

  18. Digital Doppler measurement with spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Hinedi, Sami M.; Labelle, Remi C.; Bevan, Roland P.; Del Castillo, Hector M.; Chong, Dwayne C.

    1991-01-01

    Digital and analog phase-locked loop (PLL) receivers were operated in parallel, each tracking the residual carrier from a spacecraft. The PLL tracked the downlink carrier and measured its instantaneous phase. This information, combined with a knowledge of the uplink carrier and the transponder ratio, permitted the computation of a Doppler observable. In this way, two separate Doppler measurements were obtained for one observation window. The two receivers agreed on the magnitude of the Doppler effect to within 1 mHz. There was less jitter on the data from the digital receiver. This was due to its smaller noise bandwidth. The demonstration and its results are described.

  19. Evaluation of meteorological airborne Doppler radar

    NASA Technical Reports Server (NTRS)

    Hildebrand, P. H.; Mueller, C. K.

    1984-01-01

    This paper will discuss the capabilities of airborne Doppler radar for atmospheric sciences research. The evaluation is based on airborne and ground based Doppler radar observations of convective storms. The capability of airborne Doppler radar to measure horizontal and vertical air motions is evaluated. Airborne Doppler radar is shown to be a viable tool for atmospheric sciences research.

  20. Doppler characteristics of sea clutter.

    SciTech Connect

    Raynal, Ann Marie; Doerry, Armin Walter

    2010-06-01

    Doppler radars can distinguish targets from clutter if the target's velocity along the radar line of sight is beyond that of the clutter. Some targets of interest may have a Doppler shift similar to that of clutter. The nature of sea clutter is different in the clutter and exo-clutter regions. This behavior requires special consideration regarding where a radar can expect to find sea-clutter returns in Doppler space and what detection algorithms are most appropriate to help mitigate false alarms and increase probability of detection of a target. This paper studies the existing state-of-the-art in the understanding of Doppler characteristics of sea clutter and scattering from the ocean to better understand the design and performance choices of a radar in differentiating targets from clutter under prevailing sea conditions.

  1. Doppler tracking of planetary spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.

    1992-01-01

    This article concerns the measurement of Doppler shift on microwave links that connect planetary spacecraft with the Deep Space Network. Such measurements are made by tracking the Doppler effect with phase-locked loop receivers. A description of equipment and techniques as well as a summary of the appropriate mathematical models are given. The two-way Doppler shift is measured by transmitting a highly-stable microwave (uplink) carrier from a ground station, having the spacecraft coherently transpond this carrier, and using a phase-locked loop receiver at the ground station to track the returned (downlink) carrier. The largest sources of measurement error are usually plasma noise and thermal noise. The plasma noise, which may originate in the ionosphere or the solar corona, is discussed; and a technique to partially calibrate its effect, involving the use of two simultaneous downlink carriers that are coherently related, is described. Range measurements employing Doppler rate-aiding are also described.

  2. Dual-Doppler Feasibility Study

    NASA Technical Reports Server (NTRS)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  3. Mathematical Models for Doppler Measurements

    NASA Technical Reports Server (NTRS)

    Lear, William M.

    1987-01-01

    Error analysis increases precision of navigation. Report presents improved mathematical models of analysis of Doppler measurements and measurement errors of spacecraft navigation. To take advantage of potential navigational accuracy of Doppler measurements, precise equations relate measured cycle count to position and velocity. Drifts and random variations in transmitter and receiver oscillator frequencies taken into account. Mathematical models also adapted to aircraft navigation, radar, sonar, lidar, and interferometry.

  4. Novel instantaneous laser Doppler velocimeter.

    PubMed

    Avidor, J M

    1974-02-01

    A laser Doppler velocimeter capable of directly measuring instantaneous velocities is described. The new LDV uses a novel detection technique based on the utilization of a static slightly defocused spherical Fabry-Perot interferometer used in conjunction with a special mask for the detection of instantaneous Doppler frequency shifts. The essential characteristics of this LDV are discussed, and such a system recently developed is described. Results of turbulent flow measurements show good agreement with data obtained using hot wire anemometry.

  5. High Resolution Doppler Lidar

    NASA Technical Reports Server (NTRS)

    1996-01-01

    This Grant supported the development of an incoherent lidar system to measure winds and aerosols in the lower atmosphere. During this period the following activities occurred: (1) an active feedback system was developed to improve the laser frequency stability; (2) a detailed forward model of the instrument was developed to take into account many subtle effects, such as detector non-linearity; (3) a non-linear least squares inversion method was developed to recover the Doppler shift and aerosol backscatter without requiring assumptions about the molecular component of the signal; (4) a study was done of the effects of systematic errors due to multiple etalon misalignment. It was discovered that even for small offsets and high aerosol loadings, the wind determination can be biased by as much as 1 m/s. The forward model and inversion process were modified to account for this effect; and (5) the lidar measurements were validated using rawinsonde balloon measurements. The measurements were found to be in agreement within 1-2 m/s.

  6. Adaptive spectral doppler estimation.

    PubMed

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-04-01

    In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence. The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to provide good spectral resolution and contrast even when the observation window is very short. The 2 adaptive techniques are tested and compared with the averaged periodogram (Welch's method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set of matched filters (one for each velocity component of interest) and filtering the blood process over slow-time and averaging over depth to find the PSD. The methods are tested using various experiments and simulations. First, controlled flow-rig experiments with steady laminar flow are carried out. Simulations in Field II for pulsating flow resembling the femoral artery are also analyzed. The simulations are followed by in vivo measurement on the common carotid artery. In all simulations and experiments it was concluded that the adaptive methods display superior performance for short observation windows compared with the averaged periodogram. Computational costs and implementation details are also discussed.

  7. High Resolution Doppler Imager

    NASA Technical Reports Server (NTRS)

    Hays, Paul B.

    1999-01-01

    This report summarizes the accomplishments of the High Resolution Doppler Imager (HRDI) on UARS spacecraft during the period 4/l/96 - 3/31/99. During this period, HRDI operation, data processing, and data analysis continued, and there was a high level of vitality in the HRDI project. The HRDI has been collecting data from the stratosphere, mesosphere, and lower thermosphere since instrument activation on October 1, 1991. The HRDI team has stressed three areas since operations commenced: 1) operation of the instrument in a manner which maximizes the quality and versatility of the collected data; 2) algorithm development and validation to produce a high-quality data product; and 3) scientific studies, primarily of the dynamics of the middle atmosphere. There has been no significant degradation in the HRDI instrument since operations began nearly 8 years ago. HRDI operations are fairly routine, although we have continued to look for ways to improve the quality of the scientific product, either by improving existing modes, or by designing new ones. The HRDI instrument has been programmed to collect data for new scientific studies, such as measurements of fluorescence from plants, measuring cloud top heights, and lower atmosphere H2O.

  8. Planetary Doppler Imaging

    NASA Astrophysics Data System (ADS)

    Murphy, N.; Jefferies, S.; Hart, M.; Hubbard, W. B.; Showman, A. P.; Hernandez, G.; Rudd, L.

    2014-12-01

    Determining the internal structure of the solar system's gas and ice giant planets is key to understanding their formation and evolution (Hubbard et al., 1999, 2002, Guillot 2005), and in turn the formation and evolution of the solar system. While internal structure can be constrained theoretically, measurements of internal density distributions are needed to uncover the details of the deep interior where significant ambiguities exist. To date the interiors of giant planets have been probed by measuring gravitational moments using spacecraft passing close to, or in orbit around the planet. Gravity measurements are effective in determining structure in the outer envelope of a planet, and also probing dynamics (e.g. the Cassini and Juno missions), but are less effective in probing deep structure or the presence of discrete boundaries. A promising technique for overcoming this limitation is planetary seismology (analogous to helioseismology in the solar case), postulated by Vorontsov, 1976. Using trapped pressure waves to probe giant planet interiors allows insight into the density and temperature distribution (via the sound speed) down to the planetary core, and is also sensitive to sharp boundaries, for example at the molecular to metallic hydrogen transition or at the core-envelope interface. Detecting such boundaries is not only important in understanding the overall structure of the planet, but also has implications for our understanding of the basic properties of matter at extreme pressures. Recent Doppler measurements of Jupiter by Gaulme et al (2011) claimed a promising detection of trapped oscillations, while Hedman and Nicholson (2013) have shown that trapped waves in Saturn cause detectable perturbations in Saturn's C ring. Both these papers have fueled interest in using seismology as a tool for studying the solar system's giant planets. To fully exploit planetary seismology as a tool for understanding giant planet structure, measurements need to be made

  9. Differential Doppler as a diagnostic

    SciTech Connect

    Dzieciuch, M.; Munk, W. )

    1994-10-01

    Differential Doppler compression and travel time of individual peaks in the arrival sequence (relative to an overall average) are measured for the 5500-km acoustic transmissions from a moving source at Heard Island to Christmas (Crab) Island. The differentials cannot be explained by simple adiabatic propagation models. A hybrid theory, coupling polar and temperate models at the Antarctic Front can account for some of the qualitative features. Differential Doppler could be a useful tool for identifying ray arrivals. 10 refs., 11 figs., 3 tabs.

  10. Continuous wave ultrasonic Doppler tomography

    PubMed Central

    Liang, Haidong-Dong; Tsui, Chun Sing Louis; Halliwell, Michael; Wells, Peter N. T.

    2011-01-01

    In continuous wave ultrasonic Doppler tomography (DT), the ultrasonic beam moves relative to the scanned object to acquire Doppler-shifted frequency spectra which correspond to cross-range projections of the scattering and reflecting structures within the object. The relative motion can be circular or linear. These data are then backprojected to reconstruct the two-dimensional image of the object cross section. By using coherent processing, the spatial resolution of ultrasonic DT is close to an order of magnitude better than that of traditional pulse-echo imaging at the same ultrasound frequency. PMID:22866236

  11. Right Ventricular Tissue Doppler in Space Flight

    NASA Technical Reports Server (NTRS)

    Garcia, Kathleen M.; Hamilton, Douglas R.; Sargsyan, Ashot E.; Ebert, Douglas; Martin, David S.; Barratt, Michael R.; Martin, David S.; Bogomolov, Valery V.; Dulchavsky, Scott A.; Duncan, J. Michael

    2010-01-01

    The presentation slides review normal physiology of the right ventricle in space, general physiology of the right ventricle; difficulties in imaging the heart in space, imaging methods, tissue Doppler spectrum, right ventricle tissue Doppler, and Rt Tei Index.

  12. Doppler Ultrasound: What Is It Used for?

    MedlinePlus

    ... in your neck (carotid artery stenosis) A Doppler ultrasound can estimate how fast blood flows by measuring the rate of change in its pitch (frequency). During a Doppler ultrasound, a technician trained in ultrasound imaging (sonographer) presses ...

  13. Understanding Doppler Broadening of Gamma Rays

    SciTech Connect

    Rawool-Sullivan, Mohini; Sullivan, John P.

    2014-07-03

    Doppler-broadened gamma ray peaks are observed routinely in the collection and analysis of gamma-ray spectra. If not recognized and understood, the appearance of Doppler broadening can complicate the interpretation of a spectrum and the correct identification of the gamma ray-emitting material. We have conducted a study using a simulation code to demonstrate how Doppler broadening arises and provide a real-world example in which Doppler broadening is found. This report describes that study and its results.

  14. Doppler observations of solar rotation

    NASA Technical Reports Server (NTRS)

    Scherrer, P. H.; Wilcox, J. M.

    1980-01-01

    Daily observations of the photospheric equatorial rotation rate using the Doppler effect are made at the Stanford Solar Observatory. These observations show no variations in the rotation rate that exceed the observational error of about 1%. The average rotation rate is indistinguishable from that of sunspots and large-scale magnetic field structures.

  15. Doppler Imaging of EI Eridani

    NASA Astrophysics Data System (ADS)

    Washuettl, Albert; Strassmeier, Klaus G.; Collier-Cameron, Andrew

    We present Doppler images of the rapidly rotating active close binary star EI Eridani. Several Doppler images have been produced since 1984 making use of different versions of the Doppler imaging technique. They all show high-latitude spots surrounding or covering the rotational pole as well as some smaller spots on lower latitudes. The high-latitude/polar spot seems to be long-lived (at least a decade) but changes its shape on comparatively short timescales (of the order of one month). From time to time spots along the stellar equator also occur, but their lifetimes tend to be relatively short (weeks). Furthermore, long-term photometric observations revealed the existence of a magnetic cycle which has been estimated to be around 11 years. We also present time-resolved Doppler images from EI Eri obtained at McMath/NSO in fall 1996 during 70 consecutive nights. The final aim of this program is to investigate the spot evolution over the whole activity cycle.

  16. Doppler observations of solar rotation

    NASA Technical Reports Server (NTRS)

    Scherrer, P. H.

    1980-01-01

    Daily observations of the photospheric equatorial rotation rate using the Doppler effect mode at the Sanford Solar Observatory are presented. These observations show no variations in the rotation rate that exceed the observational error of about one percent. The average rotation rate is indistinguishable from that of sunspots and large scale magnetic field structures.

  17. Doppler observations of solar rotation

    NASA Technical Reports Server (NTRS)

    Scherrer, P. H.; Wilcox, J. M.

    1980-01-01

    Daily observations of the photospheric equatorial rotation rate using the Doppler effect are made at the Stanford Solar Observatory. These observations show no variations in the rotation rate that exceed the observational error of about 1%. The average rotation rate is indistinguishable from that of sunspots and large-scale magnetic field structures.

  18. The Doppler Effect--A New Approach

    ERIC Educational Resources Information Center

    Allen, J.

    1973-01-01

    Discusses the Doppler effect as it applies to different situations, such as a stationary source of sound with the observer moving, a stationary observer, and the sound source and observer both moving. Police radar, satellite surveillance radar, radar astronomy, and the Doppler navigator, are discussed as applications of Doppler shift. (JR)

  19. The Doppler Effect--A New Approach

    ERIC Educational Resources Information Center

    Allen, J.

    1973-01-01

    Discusses the Doppler effect as it applies to different situations, such as a stationary source of sound with the observer moving, a stationary observer, and the sound source and observer both moving. Police radar, satellite surveillance radar, radar astronomy, and the Doppler navigator, are discussed as applications of Doppler shift. (JR)

  20. Human polarimetric micro-doppler

    NASA Astrophysics Data System (ADS)

    Tahmoush, David; Silvious, Jerry

    2011-06-01

    Modern radars can pick up target motions other than just the principle target Doppler; they pick out the small micro-Doppler variations as well. These can be used to visually identify both the target type as well as the target activity. We model and measure some of the micro-Doppler motions that are amenable to polarimetric measurement. Understanding the capabilities and limitations of radar systems that utilize micro-Doppler to measure human characteristics is important for improving the effectiveness of these systems at securing areas. In security applications one would like to observe humans unobtrusively and without privacy issues, which make radar an effective approach. In this paper we focus on the characteristics of radar systems designed for the estimation of human motion for the determination of whether someone is loaded. Radar can be used to measure the direction, distance, and radial velocity of a walking person as a function of time. Detailed radar processing can reveal more characteristics of the walking human. The parts of the human body do not move with constant radial velocity; the small micro-Doppler signatures are timevarying and therefore analysis techniques can be used to obtain more characteristics. Looking for modulations of the radar return from arms, legs, and even body sway are being assessed by researchers. We analyze these techniques and focus on the improved performance that fully polarimetric radar techniques can add. We perform simulations and fully polarimetric measurements of the varying micro-Doppler signatures of humans as a function of elevation angle and azimuthal angle in order to try to optimize this type of system for the detection of arm motion, especially for the determination of whether someone is carrying something in their arms. The arm is often bent at the elbow, providing a surface similar to a dihedral. This is distinct from the more planar surfaces of the body and allows us to separate the signals from the arm (and

  1. Amplitude-coded color doppler: clinical applications.

    PubMed

    Turetschek, K; Kollmann, C; Dorffner, R; Wunderbaldinger, P; Mostbeck, G

    1999-01-01

    Amplitude-coded color Doppler sonography (ACD) has become an useful adjunct to gray-scale US and conventional color Doppler sonography (CD) for the assessment of vascular diseases and pathologic conditions that might affect or alter tissue vascularization or perfusion. Basically, all US units that generate conventional color Doppler information through autocorrelation technique are capable of displaying ACD. This technique is also referred to as power Doppler, amplitude-mode color Doppler US, color Doppler energy (CDE), or US angiography. Amplitude-coded color Doppler sonography has already emerged as a valuable adjunct to conventional CD, particularly for evaluating flow in parts of the body where CD signal is weak because of slow flow, small blood vessels, or both.

  2. The calibration of Doppler receivers

    NASA Astrophysics Data System (ADS)

    Jaks, W.

    A study to determine the relative positions of the antennas of two simultaneously operating Doppler receivers and the systematic corrections needed for a given type of receiver is presented. The types of receivers included in the study are listed and results showing the differences between the geocentric coordinates of the antenna phase centers of the receivers are given. It is found that, for DOG receivers, each antenna phase center must be determined separately.

  3. Doppler ultrasound evaluation in preeclampsia

    PubMed Central

    2013-01-01

    Background Worldwide preeclampsia (PE) is the leading cause of maternal death and affects 5 to 8% of pregnant women. PE is characterized by elevated blood pressure and proteinuria. Doppler Ultrasound (US) evaluation has been considered a useful method for prediction of PE; however, there is no complete data about the most frequently altered US parameters in the pathology. The aim of this study was to evaluate the uterine, umbilical, and the middle cerebral arteries using Doppler US parameters [resistance index (RI), pulsatility index (PI), notch (N), systolic peak (SP) and their combinations] in pregnant women, in order to make a global evaluation of hemodynamic repercussion caused by the established PE. Results A total of 102 pregnant Mexican women (65 PE women and 37 normotensive women) were recruited in a cases and controls study. Blood velocity waveforms from uterine, umbilical, and middle cerebral arteries, in pregnancies from 24 to 37 weeks of gestation were recorded by trans-abdominal examination with a Toshiba Ultrasound Power Vision 6000 SSA-370A, with a 3.5 MHz convex transducer. Abnormal general Doppler US profile showed a positive association with PE [odds ratio (OR) = 2.93, 95% confidence interval (CI) = 1.2 - 7.3, P = 0.021)], and a specificity and predictive positive value of 89.2% and 88.6%, respectively. Other parameters like N presence, RI and PI of umbilical artery, as well as the PI of middle cerebral artery, showed differences between groups (P values < 0.05). Conclusion General Doppler US result, as well as N from uterine vessel, RI from umbilical artery, and PI from umbilical and middle cerebral arteries in their individual form, may be considered as tools to determine hemodynamic repercussion caused by PE. PMID:24252303

  4. Doppler ultrasound evaluation in preeclampsia.

    PubMed

    Lopez-Mendez, Maria A; Martinez-Gaytan, Victoria; Cortes-Flores, Raul; Ramos-Gonzalez, Rene M; Ochoa-Torres, Mauro A; Garza-Veloz, Idalia; Martinez-Acuña, Monica I; Badillo-Almaraz, Jose I; Martinez-Fierro, Margarita L

    2013-11-19

    Worldwide preeclampsia (PE) is the leading cause of maternal death and affects 5 to 8% of pregnant women. PE is characterized by elevated blood pressure and proteinuria. Doppler Ultrasound (US) evaluation has been considered a useful method for prediction of PE; however, there is no complete data about the most frequently altered US parameters in the pathology. The aim of this study was to evaluate the uterine, umbilical, and the middle cerebral arteries using Doppler US parameters [resistance index (RI), pulsatility index (PI), notch (N), systolic peak (SP) and their combinations] in pregnant women, in order to make a global evaluation of hemodynamic repercussion caused by the established PE. A total of 102 pregnant Mexican women (65 PE women and 37 normotensive women) were recruited in a cases and controls study. Blood velocity waveforms from uterine, umbilical, and middle cerebral arteries, in pregnancies from 24 to 37 weeks of gestation were recorded by trans-abdominal examination with a Toshiba Ultrasound Power Vision 6000 SSA-370A, with a 3.5 MHz convex transducer. Abnormal general Doppler US profile showed a positive association with PE [odds ratio (OR) = 2.93, 95% confidence interval (CI) = 1.2 - 7.3, P = 0.021)], and a specificity and predictive positive value of 89.2% and 88.6%, respectively. Other parameters like N presence, RI and PI of umbilical artery, as well as the PI of middle cerebral artery, showed differences between groups (P values < 0.05). General Doppler US result, as well as N from uterine vessel, RI from umbilical artery, and PI from umbilical and middle cerebral arteries in their individual form, may be considered as tools to determine hemodynamic repercussion caused by PE.

  5. Doppler Imaging of PW And

    NASA Astrophysics Data System (ADS)

    Kolbin, A. I.; Galeev, A. I.

    2017-06-01

    In this work we have investigated spottiness of the young active K2-dwarf PW And. The spottiness analysis was based on high resolution spectroscopic observations obtained by 1.5-m Russian-Turkish telescope on September-October, 2015. The least square deconvolution technique was used to increase S/N of analyzed line profiles. The reconstruction of the spots distribution was performed by developed Doppler imaging codes. It was found that spots concentrate at intermediate latitudes.

  6. Ultrasound imaging for the rheumatologist. XVII. Role of colour Doppler and power Doppler.

    PubMed

    Iagnocco, A; Epis, O; Delle Sedie, A; Meenagh, G; Filippucci, E; Riente, L; Scirè, C A; Montecucco, C; Bombardieri, S; Grassi, W; Valesini, G

    2008-01-01

    The use of Doppler ultrasound in rheumatology has grown in recent years. This is partly due to the increasing number of rheumatologists who perform US in their daily clinical practise and also to the technological advances of US systems. Both colour Doppler and power Doppler are used to evaluate the degree of intra- and peri-articular soft tissue inflammation. Moreover, Doppler US has been found to be of help in the assessment of vascular pathologies such as the vasculitides. In this review we provide an update of the data regarding the use of colour Doppler and power Doppler in rheumatology.

  7. Measurement of the Doppler power of flowing blood using ultrasound Doppler devices.

    PubMed

    Huang, Chih-Chung; Chou, Hung-Lung; Chen, Pay-Yu

    2015-02-01

    Measurement of the Doppler power of signals backscattered from flowing blood (henceforth referred to as the Doppler power of flowing blood) and the echogenicity of flowing blood have been used widely to assess the degree of red blood cell (RBC) aggregation for more than 20 y. Many studies have used Doppler flowmeters based on an analogue circuit design to obtain the Doppler shifts in the signals backscattered from flowing blood; however, some recent studies have mentioned that the analogue Doppler flowmeter exhibits a frequency-response problem whereby the backscattered energy is lost at higher Doppler shift frequencies. Therefore, the measured Doppler power of flowing blood and evaluations of RBC aggregation obtained using an analogue Doppler device may be inaccurate. To overcome this problem, the present study implemented a field-programmable gate array-based digital pulsed-wave Doppler flowmeter to measure the Doppler power of flowing blood, in the aim of providing more accurate assessments of RBC aggregation. A clinical duplex ultrasound imaging system that can acquire pulsed-wave Doppler spectrograms is now available, but its usefulness for estimating the ultrasound scattering properties of blood is still in doubt. Therefore, the echogenicity and Doppler power of flowing blood under the same flow conditions were measured using a laboratory pulser-receiver system and a clinical ultrasound system, respectively, for comparisons. The experiments were carried out using porcine blood under steady laminar flow with both RBC suspensions and whole blood. The experimental results indicated that a clinical ultrasound system used to measure the Doppler spectrograms is not suitable for quantifying Doppler power. However, the Doppler power measured using a digital Doppler flowmeter can reveal the relationship between backscattering signals and the properties of blood cells because the effects of frequency response are eliminated. The measurements of the Doppler power and

  8. Performance Of A Doppler-Corrected MDPSK Detector

    NASA Technical Reports Server (NTRS)

    Nguyen, Tien M.; Jedrey, Thomas C.; Hinedi, Sami; Agan, Martin J.

    1994-01-01

    Report presents theoretical analysis of effect of rate of change of Doppler shift of received multiple-differential-phase-shift-keyed (MDPSK) radio signal on performance of Doppler-corrected differential detector. In particular detector, phase of received signal corrected for Doppler shift by use of Doppler estimator designed to operate in presence of negligibly small Doppler rate.

  9. Equations for Bistatic Doppler Shift and Rate of Change of Doppler Shift of Dark Satellite Observations

    DTIC Science & Technology

    Equations are given for the doppler shift and rate of change of doppler shift for the bistatic case where an orbiting, nontransmitting earth... of change of doppler shift, satellite height, earth-center angle between the receiver and the satellite, and zenith angle from receiver to satellite are shown for a typical satellite, 1958 Alpha, Explorer I....have been computed, using transmitting and receiving sites of the Space Surveillance System. Plots of various relationships between doppler shift, rate

  10. [Doppler color in superficial adenopathies].

    PubMed

    Giovagnorio, F

    1999-03-01

    Superficial lymph nodes are frequently involved in different diseases. Their location makes them suitable for effective assessment with high-resolution US and color Doppler has been recently suggested as a tool for increasing sensitivity in lymph node studies. Thus, we investigated the main vascular patterns detectable in abnormal superficial lymph nodes. We evaluated 260 nodes in 180 adult patients; the nodes were located in the cervicofacial ring (78, 30%), internal jugular stations (104, 40%), and supraclavicular (44, 17%), axillary (21, 8%), and inguinal (13, 5%) stations. Color Doppler was performed with 7.5-13 MHz linear transducers, with parameters adjusted for slow-flow detection (5-6 MHz frequency, 700-900 Hz PRF, 50 Hz band filter, high color persistence). Disease assessment required fine-needle biopsy (95 nodes in 95 patients) and clinical follow-up (165 nodes in 85 patients). Fifty-five nodes (21%) presented acute and 130 (50%) chronic inflammation: 75 nodes (29%) were metastatic. The following vascular patterns were detected: a single vascular pole (type I) was seen in chronic inflammation (72% sensitivity, 86% specificity, 57% positive and 92% negative predictive value); an enlarged single vascular pole, with 2-3 enlarged branches (type II) in acute adenitis (80% sensitivity, 81% specificity, 78% positive and 83% negative predictive value); multiple vascular poles with many deformed and displaced branches converging centrally (type III) in metastases (76% sensitivity, 100% specificity, 100% positive and 91% negative predictive value). We conclude that color and power Doppler are useful integrations to B-mode US because they can detect specific signs of malignancy such as peripheral vascular poles and intranodal displacement of vessels.

  11. Comparison of transvaginal color Doppler imaging and color Doppler energy for assessment of intraovarian blood flow.

    PubMed

    Tailor, A; Jurkovic, D; Bourne, T H; Natucci, M; Collins, W P; Campbell, S

    1998-04-01

    To investigate any systematic differences in the analysis of blood flow velocity waveforms derived by color Doppler imaging and color Doppler energy examination of corpora lutea and adnexal tumors, to test whether the accuracy for diagnosing ovarian malignancy differs between end points derived by color Doppler imaging and color Doppler energy, and to compare the reproducibility of flow velocity waveform analysis obtained by both methods. Fifty-six asymptomatic women with presumed corpora lutea and 67 women with known adnexal masses were included in the study. They all were examined using transvaginal sonography with color Doppler imaging and color Doppler energy. Pulsed Doppler sonography was used to obtain flow velocity waveforms to determine the pulsatility index (PI), resistance index (RI), peak systolic velocity, and time-averaged maximum velocity. The tumors were classified retrospectively according to histologic criteria. There were 52 women with benign, three with borderline, and 12 with malignant ovarian tumors. Repeated-measures analysis of variance revealed no systematic differences in the values of all four measurements performed under color Doppler imaging and color Doppler energy for all cases of corpora lutea and adnexal tumors (PI: P=.153, RI: P=.197, peak systolic velocity: P=.355, time-averaged maximum velocity: P=.159). All cases of borderline and malignant tumors had detectable pulsatile blood flow with color Doppler imaging and color Doppler energy. Forty-two (80.8%) of the benign tumors had flow detectable with color Doppler imaging, compared with 40 (76.9%) with color Doppler energy (P=.480). Analysis of receiver operating characteristic curves showed a marginal but nonsignificant improvement in diagnostic performance with color Doppler energy compared with color Doppler imaging for all four measurements (PI: P=.182, RI: P=.178, peak systolic velocity: P=.254, time-averaged maximum velocity: P=.238). The intraclass correlation coefficients

  12. Luminosity Dependence and Search Doppler

    NASA Technical Reports Server (NTRS)

    VanParadijs, Johannes A.

    1998-01-01

    The research supported by this grant covered two projects: (1) a study of the luminosity dependence of the properties of atoll sources; and (2) a search for Doppler shifts in the pulse arrival times of the anomalous pulsar 4U 0142+61. Following the discovery of kilohertz quasi-periodic oscillations (QPOS) in Sco X-1 studies of the X-ray properties of atoll sources have been dominated by searches for these QPOS, and the study of their dependence on other source properties, such as X-ray luminosity and spectral state. In the project supported by grant NAG5-3269 we have detected kHz QPOs for several atoll sources. The physical interpretation of these QPO is as yet unclear, but simple models (such as the Keplerian beat frequency model) can probably be excluded. The results of this research have been reported. We have studied the X-ray pulsations of the anomalous X-ray pulsar 4U 0142+61 using the Rossi XTE. A detailed search for Doppler shifts did not lead to a positive detection. The upper limits exclude almost all types of possible companion stars, except white dwarfs. However, the latter can be excluded since anomalous X-ray pulsars are very young objects. We therefore conclude that anomalous X-ray pulsars are single neutron stars.

  13. Doppler ultrasound exam of an arm or leg

    MedlinePlus

    ... the risk of problems with the heart and circulatory system. Most smoking-related deaths are caused by cardiovascular problems, not lung cancer. Alternative Names Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg ...

  14. Airborne Differential Doppler Weather Radar

    NASA Technical Reports Server (NTRS)

    Meneghini, R.; Bidwell, S.; Liao, L.; Rincon, R.; Heymsfield, G.; Hildebrand, Peter H. (Technical Monitor)

    2001-01-01

    The Precipitation Radar aboard the Tropical Rain Measuring Mission (TRMM) Satellite has shown the potential for spaceborne sensing of snow and rain by means of an incoherent pulsed radar operating at 13.8 GHz. The primary advantage of radar relative to passive instruments arises from the fact that the radar can image the 3-dimensional structure of storms. As a consequence, the radar data can be used to determine the vertical rain structure, rain type (convective/stratiform) effective storm height, and location of the melting layer. The radar, moreover, can be used to detect snow and improve the estimation of rain rate over land. To move toward spaceborne weather radars that can be deployed routinely as part of an instrument set consisting of passive and active sensors will require the development of less expensive, lighter-weight radars that consume less power. At the same time, the addition of a second frequency and an upgrade to Doppler capability are features that are needed to retrieve information on the characteristics of the drop size distribution, vertical air motion and storm dynamics. One approach to the problem is to use a single broad-band transmitter-receiver and antenna where two narrow-band frequencies are spaced apart by 5% to 10% of the center frequency. Use of Ka-band frequencies (26.5 GHz - 40 GHz) affords two advantages: adequate spatial resolution can be attained with a relatively small antenna and the differential reflectivity and mean Doppler signals are directly related to the median mass diameter of the snow and raindrop size distributions. The differential mean Doppler signal has the additional property that this quantity depends only on that part of the radial speed of the hydrometeors that is drop-size dependent. In principle, the mean and differential mean Doppler from a near-nadir viewing radar can be used to retrieve vertical air motion as well as the total mean radial velocity. In the paper, we present theoretical calculations for the

  15. Airborne Differential Doppler Weather Radar

    NASA Technical Reports Server (NTRS)

    Meneghini, R.; Bidwell, S.; Liao, L.; Rincon, R.; Heymsfield, G.; Hildebrand, Peter H. (Technical Monitor)

    2001-01-01

    The Precipitation Radar aboard the Tropical Rain Measuring Mission (TRMM) Satellite has shown the potential for spaceborne sensing of snow and rain by means of an incoherent pulsed radar operating at 13.8 GHz. The primary advantage of radar relative to passive instruments arises from the fact that the radar can image the 3-dimensional structure of storms. As a consequence, the radar data can be used to determine the vertical rain structure, rain type (convective/stratiform) effective storm height, and location of the melting layer. The radar, moreover, can be used to detect snow and improve the estimation of rain rate over land. To move toward spaceborne weather radars that can be deployed routinely as part of an instrument set consisting of passive and active sensors will require the development of less expensive, lighter-weight radars that consume less power. At the same time, the addition of a second frequency and an upgrade to Doppler capability are features that are needed to retrieve information on the characteristics of the drop size distribution, vertical air motion and storm dynamics. One approach to the problem is to use a single broad-band transmitter-receiver and antenna where two narrow-band frequencies are spaced apart by 5% to 10% of the center frequency. Use of Ka-band frequencies (26.5 GHz - 40 GHz) affords two advantages: adequate spatial resolution can be attained with a relatively small antenna and the differential reflectivity and mean Doppler signals are directly related to the median mass diameter of the snow and raindrop size distributions. The differential mean Doppler signal has the additional property that this quantity depends only on that part of the radial speed of the hydrometeors that is drop-size dependent. In principle, the mean and differential mean Doppler from a near-nadir viewing radar can be used to retrieve vertical air motion as well as the total mean radial velocity. In the paper, we present theoretical calculations for the

  16. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    NASA Astrophysics Data System (ADS)

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-08-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  17. Observation of the Zero Doppler Effect.

    PubMed

    Ran, Jia; Zhang, Yewen; Chen, Xiaodong; Fang, Kai; Zhao, Junfei; Chen, Hong

    2016-04-05

    The normal Doppler effect has well-established applications in many areas of science and technology. Recently, a few experimental demonstrations of the inverse Doppler effect have begun to appear in negative-index metamaterials. Here we report an experimental observation of the zero Doppler effect, that is, no frequency shift irrespective of the relative motion between the wave signal source and the detector in a zero-index metamaterial. This unique phenomenon, accompanied by the normal and inverse Doppler effects, is generated by reflecting a wave from a moving discontinuity in a composite right/left-handed transmission line loaded with varactors when operating in the near zero-index passband, or the right/left-handed passband. This work has revealed a complete picture of the Doppler effect in metamaterials and may lead to potential applications in electromagnetic wave related metrology.

  18. Observation of the Zero Doppler Effect

    PubMed Central

    Ran, Jia; Zhang, Yewen; Chen, Xiaodong; Fang, Kai; Zhao, Junfei; Chen, Hong

    2016-01-01

    The normal Doppler effect has well-established applications in many areas of science and technology. Recently, a few experimental demonstrations of the inverse Doppler effect have begun to appear in negative-index metamaterials. Here we report an experimental observation of the zero Doppler effect, that is, no frequency shift irrespective of the relative motion between the wave signal source and the detector in a zero-index metamaterial. This unique phenomenon, accompanied by the normal and inverse Doppler effects, is generated by reflecting a wave from a moving discontinuity in a composite right/left-handed transmission line loaded with varactors when operating in the near zero-index passband, or the right/left-handed passband. This work has revealed a complete picture of the Doppler effect in metamaterials and may lead to potential applications in electromagnetic wave related metrology. PMID:27046395

  19. Inverse Doppler Effects in Broadband Acoustic Metamaterials.

    PubMed

    Zhai, S L; Zhao, X P; Liu, S; Shen, F L; Li, L L; Luo, C R

    2016-08-31

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with 'flute-like' acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  20. Development of the doppler electron velocimeter: theory.

    SciTech Connect

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  1. Laser Doppler dust devil measurements

    NASA Technical Reports Server (NTRS)

    Bilbro, J. W.; Jeffreys, H. B.; Kaufman, J. W.; Weaver, E. A.

    1977-01-01

    A scanning laser doppler velocimeter (SLDV) system was used to detect, track, and measure the velocity flow field of naturally occurring tornado-like flows (dust devils) in the atmosphere. A general description of the dust devil phenomenon is given along with a description of the test program, measurement system, and data processing techniques used to collect information on the dust devil flow field. The general meteorological conditions occurring during the test program are also described, and the information collected on two selected dust devils are discussed in detail to show the type of information which can be obtained with a SLDV system. The results from these measurements agree well with those of other investigators and illustrate the potential for the SLDV in future endeavors.

  2. Role of 3D power Doppler sonography in early prenatal diagnosis of Galen vein aneurysm

    PubMed Central

    Ergenoğlu, Mete Ahmet; Yeniel, Ahmet Özgür; Akdemir, Ali; Akercan, Fuat; Karadadaş, Nedim

    2013-01-01

    Vein of Galen aneurysm malformation (VGAM) is a rare congenital vascular anomaly. Although the cause of VGAM remains to be elucidated, the current hypothesis is persistence of the embryonic vascular supply, which leads to progressive enlargement and formation of the aneurysmal component of a typical VGAM. Here, we present a 36-year-old woman at 23 weeks’ gestation (gravida 3, para 2) who was evaluated using 3D power Doppler sonography for the prenatal diagnosis of a vein of Galen aneurysm. Investigation using 3D power Doppler sonography allowed for a non-invasive yet diffuse and detailed prenatal assessment of VGAM. Thus, we suggest that prenatal sonography with 3D power Doppler may be an option in cases of VGAM. PMID:24592100

  3. Staggered Multiple-PRF Ultrafast Color Doppler.

    PubMed

    Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien

    2016-06-01

    Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.

  4. Wideband radar micro-doppler applications

    NASA Astrophysics Data System (ADS)

    Tahmoush, Dave

    2013-05-01

    Wideband radar provides a significant improvement over traditional narrowband radars for micro-Doppler analysis because the high bandwidth can be used to separate many of the signals in range, allowing a simpler decomposition of the micro-Doppler signals. Recent wideband radar work has focused on micro-Doppler, but there is a point where the narrowband approach used to analyze the micro-Doppler signals breaks down. The effect is shown to be independent of frequency, but the error relative to the bandwidth is shown to be inversely proportional to the frequency and proportional to the velocity of the subject. This error can create a smearing effect in the observed Doppler if it is not corrected, leading to reduced signal-to-noise and the appearance of more diffuse targets in Doppler space. In range-space, wideband data can also break the subject into several range bins, affecting the observed signal to noise ratio. The possible applications of wideband micro-Doppler radar are also shown, including the separation of arm movement from human motion which implies that the arms are not encumbered.

  5. Rotational Doppler effect in nonlinear optics

    NASA Astrophysics Data System (ADS)

    Li, Guixin; Zentgraf, Thomas; Zhang, Shuang

    2016-08-01

    The translational Doppler effect of electromagnetic and sound waves has been successfully applied in measurements of the speed and direction of vehicles, astronomical objects and blood flow in human bodies, and for the Global Positioning System. The Doppler effect plays a key role for some important quantum phenomena such as the broadened emission spectra of atoms and has benefited cooling and trapping of atoms with laser light. Despite numerous successful applications of the translational Doppler effect, it fails to measure the rotation frequency of a spinning object when the probing wave propagates along its rotation axis. This constraint was circumvented by deploying the angular momentum of electromagnetic waves--the so-called rotational Doppler effect. Here, we report on the demonstration of rotational Doppler shift in nonlinear optics. The Doppler frequency shift is determined for the second harmonic generation of a circularly polarized beam passing through a spinning nonlinear optical crystal with three-fold rotational symmetry. We find that the second harmonic generation signal with circular polarization opposite to that of the fundamental beam experiences a Doppler shift of three times the rotation frequency of the optical crystal. This demonstration is of fundamental significance in nonlinear optics, as it provides us with insight into the interaction of light with moving media in the nonlinear optical regime.

  6. Progress in Doppler picture velocimetry (DPV)

    NASA Astrophysics Data System (ADS)

    Seiler, F.; George, A.; Srulijes, J.; Havermann, M.

    2008-03-01

    The special wide-field Michelson interferometer designed at ISL transforms the Doppler frequency shift of light scattered by tracer particles crossing a light sheet into a shift of luminous intensity at the output of the Michelson interferometer, yielding information about the particle velocity. To overcome former disadvantages, the optical set-up as well as the Doppler picture-processing algorithm were further improved. The present status of Doppler picture velocimetry (DPV) is explained by means of measurements carried out at Mach 6 in the ISL shock tunnel STA. The vertical velocity distribution around several bodies, such as a wedge, a sphere and a cylinder was visualized and measured.

  7. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment.

    PubMed

    Ramnarine, K V; Hoskins, P R; Routh, H F; Davidson, F

    1999-01-01

    The Doppler backscatter properties of a blood-mimickig fluid (BMF) were studied to evaluate its suitability for use in a Doppler flow test object. Measurements were performed using a flow rig with C-flex tubing and BMF flow produced by a roller pump or a gear pump. A SciMed Doppler system was used to measure the backscattered Doppler power with a root-mean-square power meter connected to the audio output. Studies investigated the dependence of the backscattered Doppler power of the BMF with: circulation time; batch and operator preparations; storage; sieve size; flow speed; and pump type. A comparison was made with human red blood cells resuspended in saline. The backscatter properties are stable and within International Electrotechnical Commission requirements. The BMF is suitable for use in a test object for Doppler performance assessment.

  8. IIP Update: A Packaged Coherent Doppler Wind Lidar Transceiver. Doppler Aerosol WiNd Lidar (DAWN)

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Koch, Grady J.; Yu, Jirong; Trieu, Bo C.; Amzajerdian, Farzin; Singh, Upendra N.; Petros, Mulugeta

    2006-01-01

    The state-of-the-art 2-micron coherent Doppler wind lidar breadboard at NASA/LaRC will be engineered and compactly packaged consistent with future aircraft flights. The packaged transceiver will be integrated into a coherent Doppler wind lidar system test bed at LaRC. Atmospheric wind measurements will be made to validate the packaged technology. This will greatly advance the coherent part of the hybrid Doppler wind lidar solution to the need for global tropospheric wind measurements.

  9. Intensity changes in the Doppler effect

    PubMed Central

    Johnson, Montgomery H.; Teller, Edward

    1982-01-01

    When a source moves in any direction, the source strength and the frequencies are altered by the Doppler effect. It is shown that the source strength divided by the cube of the frequency is a Lorentz invariant. PMID:16593162

  10. Teaching the Doppler effect in astrophysics

    NASA Astrophysics Data System (ADS)

    Hughes, Stephen W.; Cowley, Michael

    2017-03-01

    The Doppler effect is a shift in the frequency of waves emitted from an object moving relative to the observer. By observing and analysing the Doppler shift in electromagnetic waves from astronomical objects, astronomers gain greater insight into the structure and operation of our Universe. In this paper, a simple technique is described for teaching the basics of the Doppler effect to undergraduate astrophysics students using acoustic waves. An advantage of the technique is that it produces a visual representation of the acoustic Doppler shift. The equipment comprises a 40 kHz acoustic transmitter and a microphone. The sound is bounced off a computer fan and the signal collected by a DrDAQ ADC and processed by a spectrum analyser. Widening of the spectrum is observed as the fan power supply potential is increased from 4 to 12 V.

  11. Laser Doppler Measurement of Atmopsheric Wind Velocity

    NASA Technical Reports Server (NTRS)

    Schwiesow, R. L.; Abshire, N. L.; Derr, V. E.

    1973-01-01

    Our presentation consists of two parts: (1) a summary review of laser Doppler principles and applications, and (2) operational design and preliminary laboratory tests of a CO2 laser system for NOAA applications.

  12. Epiploic appendagitis: color Doppler sonographic findings.

    PubMed

    Danse, E M; Van Beers, B E; Baudrez, V; Pauls, C; Baudrez, Y; Kartheuser, A; Thys, F; Pringot, J

    2001-01-01

    The aim of this study was to analyze the color Doppler sonographic findings in primary epiploic appendagitis. Color Doppler sonographic findings of ten patients with primary epiploic appendagitis were reviewed. The following sonographic features were analyzed: identification of a mass adjacent to the colonic wall; identification of spotty color areas with arterial flow in this mass and detection of abnormalities of the colonic wall adjacent to the infiltrated fatty tissue. A well-delineated hyperechoic mass adjacent to the colonic wall was detected in each patient with sonography. No colonic wall abnormalities were observed nor color Doppler signal in and around the hyperechoic area. Absence of flow at color Doppler sonography is an additional feature of epiploic appendagitis.

  13. Student Microwave Experiments Involving the Doppler Effect.

    ERIC Educational Resources Information Center

    Weber, F. Neff; And Others

    1980-01-01

    Described is the use of the Doppler Effect with microwaves in the measurement of the acceleration due to gravity of falling objects. The experiments described add to the repertoire of quantitative student microwave experiments. (Author/DS)

  14. Student Microwave Experiments Involving the Doppler Effect.

    ERIC Educational Resources Information Center

    Weber, F. Neff; And Others

    1980-01-01

    Described is the use of the Doppler Effect with microwaves in the measurement of the acceleration due to gravity of falling objects. The experiments described add to the repertoire of quantitative student microwave experiments. (Author/DS)

  15. Generalized Doppler Formula in a Nonstatic Universe

    ERIC Educational Resources Information Center

    Gross, Peter G.

    1977-01-01

    Derives the general Doppler formula in a nonstatic universe using assumptions of special relativity, homogeneity and isotropy of the universe. Examples of applications to physical cosmology are given. (SL)

  16. High range resolution micro-Doppler analysis

    NASA Astrophysics Data System (ADS)

    Cammenga, Zachary A.; Smith, Graeme E.; Baker, Christopher J.

    2015-05-01

    This paper addresses use of the micro-Doppler effect and the use of high range-resolution profiles to observe complex targets in complex target scenes. The combination of micro-Doppler and high range-resolution provides the ability to separate the motion of complex targets from one another. This ability leads to the differentiation of targets based on their micro-Doppler signatures. Without the high-range resolution, this would not be possible because the individual signatures would not be separable. This paper also addresses the use of the micro-Doppler information and high range-resolution profiles to generate an approximation of the scattering properties of a complex target. This approximation gives insight into the structure of the complex target and, critically, is created without using a pre-determined target model.

  17. Evaluation of a pulsed ultrasonic Doppler flowmeter

    NASA Technical Reports Server (NTRS)

    Wells, M. K.

    1973-01-01

    The in vivo application of the pulsed ultrasound Doppler velocity meter (PUDVM) for measuring arterial velocity waveforms is reported. In particular, the performance of the PUDVM is compared with a hot film anemometer of proven accuracy.

  18. Doppler vortography: a color Doppler approach for quantification of the intraventricular blood flow vortices

    PubMed Central

    Mehregan, Forough; Tournoux, François; Muth, Stéphan; Pibarot, Philippe; Rieu, Régis; Cloutier, Guy; Garcia, Damien

    2013-01-01

    We propose a new approach for quantification of intracardiac vorticity – Doppler vortography – based on conventional color Doppler images. Doppler vortography relies on the centrosymmetric properties of the vortices. Such properties induce particular symmetries in the Doppler flow data which can be exploited to describe the vortices quantitatively. For this purpose, a kernel filter was developed to derive a parameter –the blood vortex signature (BVS) – that allows detecting the main intracardiac vortices and estimating their core vorticities. The reliability of Doppler vortography was assessed in mock Doppler fields issued from simulations and in vitro data. Doppler vortography was also tested in patients and compared with vector flow mapping by echocardiography. Strong correlations were obtained between the Doppler vortography-derived and the ground-truth vorticities (in silico: r2 = 0.98, in vitro: r2 = 0.86, in vivo: r2 = 0.89). Our results demonstrated that Doppler vortography is a potentially promising echocardiographic tool for quantification of vortex flow in the left ventricle. PMID:24210865

  19. Pulsed Doppler lidar airborne scanner

    NASA Technical Reports Server (NTRS)

    Dimarzio, C. A.; Mcvicker, D. B.; Morrow, C. E.; Negus, C. C.

    1985-01-01

    This report covers the work accomplished during the reporting period on Pulsed Doppler Lidar Airborne Scanner and describes plans for the next reporting period. The objectives during the current phase of the contract are divided into four phases. Phase 1 includes ground testing of the system and analysis of data from the 1981 Severe Storms Test Flights. Phase 2 consists of preflight preparation and planning for the 1983 flight series. The flight test itself will be performed during Phase 3, and Phase 4 consists of post-flight analysis and operation of the system after that flight test. The range profile from five samples taken during Flight 10, around 1700 Z is given. The lowest curve is taken from data collected upwind of Mt. Shasta at about 10,000 feet of altitude, in a clear atmosphere, where no signals were observed. It thus is a good representation of the noise level as a function of range. The next curve was taken downwind of the mountain, and shows evidence of atmospheric returns. There is some question as to whether the data are valid at all ranges, or some ranges are contaminated by the others.

  20. Doppler micro sense and avoid radar

    NASA Astrophysics Data System (ADS)

    Gorwara, Ashok; Molchanov, Pavlo; Asmolova, Olga

    2015-10-01

    There is a need for small Sense and Avoid (SAA) systems for small and micro Unmanned Aerial Systems (UAS) to avoid collisions with obstacles and other aircraft. The proposed SAA systems will give drones the ability to "see" close up and give them the agility to maneuver through tight areas. Doppler radar is proposed for use in this sense and avoid system because in contrast to optical or infrared (IR) systems Doppler can work in more harsh conditions such as at dusk, and in rain and snow. And in contrast to ultrasound based systems, Doppler can better sense small sized obstacles such as wires and it can provide a sensing range from a few inches to several miles. An SAA systems comprised of Doppler radar modules and an array of directional antennas that are distributed around the perimeter of the drone can cover the entire sky. These modules are designed so that they can provide the direction to the obstacle and simultaneously generate an alarm signal if the obstacle enters within the SAA system's adjustable "Protection Border". The alarm signal alerts the drone's autopilot to automatically initiate an avoidance maneuver. A series of Doppler radar modules with different ranges, angles of view and transmitting power have been designed for drones of different sizes and applications. The proposed Doppler radar micro SAA system has simple circuitry, works from a 5 volt source and has low power consumption. It is light weight, inexpensive and it can be used for a variety of small unmanned aircraft.

  1. [Cerebral Doppler ultrasonography in newborn infants].

    PubMed

    Luciano, R; Velardi, F

    1995-01-01

    Following the first study of Bada et al. (1979), Doppler assessment of cerebral blood flow has increasingly been used in newborn infants, matching the technical progress in the available equipment. The experience gathered in recent years has confirmed that Doppler US is a reliable and reproducible examination while precising the limitations and the methodology to be followed in order to prevent gross errors of assessment and interpretation. The interest this procedure has arisen, among other things, stems from being noninvasive and feasible at the patient's bed. These features enable its repeated use in newborn infants in poor clinical condition. The diagnostic and prognostic role of Doppler velocimetry has been shown in a number of neonatal diseases and the cerebral hemodynamics has been assessed in physiologic conditions as well as after drug administration. The most common equipment used in newborn infants is at present Duplex Doppler consisting of a pulsed Doppler combined with bidimensional scanner, which, with visualization of study arteries, enables precise positioning of sample volume and correction of the ultrasonic angle of incidence with respect to the direction of blood flow in the examined vessel. In this report, after a survey of the techniques and modalities of cerebral Doppler examination in newborns, a review of the present state of the art, in neonatal cerebral as well as extracranial disease, is presented.

  2. Doppler-corrected differential detection system

    NASA Technical Reports Server (NTRS)

    Simon, Marvin K. (Inventor); Divsalar, Dariush (Inventor)

    1991-01-01

    Doppler in a communication system operating with a multiple differential phase-shift-keyed format (MDPSK) creates an adverse phase shift in an incoming signal. An open loop frequency estimation is derived from a Doppler-contaminated incoming signal. Based upon the recognition that, whereas the change in phase of the received signal over a full symbol contains both the differentially encoded data and the Doppler induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler induced phase shift, and the Doppler effect can be estimated and removed from the incoming signal. Doppler correction occurs prior to the receiver's final output of decoded data. A multiphase system can operate with two samplings per symbol interval at no penalty in signal-to-noise ratio provided that an ideal low pass pre-detection filter is employed, and two samples, at 1/4 and 3/4 of the symbol interval T sub s, are taken and summed together prior to incoming signal data detection.

  3. Retroreflector for photonic Doppler velocimetry

    NASA Astrophysics Data System (ADS)

    Lagoski, Thomas J.; Coutu, Ronald A., Jr.; Starman, LaVern A.

    2009-08-01

    In order to meet the goals of the Department of Defense (DoD) for smaller and more accurate weapons, numerous projects are currently investigating the miniaturization of weapons and munition fuze components. One of these efforts is to characterize the performance of small detonators. The velocity of the flyer, the key component needed to initiate a detonation sequence, can be measured using a photonic Doppler velocimeter (PDV). The purpose of this research was to develop a microelectromechanical system (MEMS) device that would act as an optimal retroreflective surface for the PDV. Two MEMS solutions were explored: one using the PolyMUMPsTM fabrication process and one in-house fabrication design using silicon on insulator (SOI) wafers. The in-house design consisted of an array of corner reflectors created using an SOI wafer. Each corner reflector consisted of three separate mirror plates which were self-assembled by photoresist pad hinges. When heated to a critical temperature (typically 140-160 °C), the photoresist pads melted and the resulting surface tension caused each mirror to rotate into place. The resulting array of corner reflectors was then coated with a thin layer of gold to increase reflectivity. Despite the successful assembly of a PolyMUMPsTM corner reflector, assembling an array of these reflectors was found to be unfeasible. Although the SOI corner reflector design was completed, these devices were not fabricated in time for testing during this research. However, the bidirectional reflectance distribution function (BRDF) and optical cross section (OCS) of commercially available retroreflective tapes were measured. These results can be used as a baseline comparison for future testing of a fabricated SOI corner reflector array.

  4. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    PubMed Central

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  5. The leicester Doppler phantom--a digital electronic phantom for ultrasound pulsed Doppler system testing.

    PubMed

    Gittins, John; Martin, Kevin

    2010-04-01

    Doppler flow and string phantoms have been used to assess the performance of ultrasound Doppler systems in terms of parameters such as sensitivity, velocity accuracy and sample volume registration. However, because of the nature of their construction, they cannot challenge the accuracy and repeatability of modern digital ultrasound systems or give objective measures of system performance. Electronic Doppler phantoms are able to make use of electronically generated test signals, which may be controlled precisely in terms of frequency, amplitude and timing. The Leicester Electronic Doppler Phantom uses modern digital signal processing methods and field programmable gate array technology to overcome some of the limitations of previously described electronic phantoms. In its present form, it is able to give quantitative graphical assessments of frequency response and range gate characteristics, as well as measures of dynamic range and velocity measurement accuracy. The use of direct acoustic coupling eliminates uncertainties caused by Doppler beam effects, such as intrinsic spectral broadening, but prevents their evaluation.

  6. Doppler-guided retrograde catheterization system

    NASA Astrophysics Data System (ADS)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  7. Color Doppler sonography in obstetrics and gynecology.

    PubMed

    Fleischer, Arthur C; Andreotti, Rochelle F

    2005-09-01

    This review aims to provide the reader with an overview of the present and future clinical applications in color Doppler sonography for the evaluation of vascularity and blood flow within the uterus (both gravid and nongravid), ovaries, fetus and placenta. The clinical use of color Doppler sonography has been demonstrated within many organ systems. Color Doppler sonography has become an integral part of cardiovascular imaging. Significant improvements have recently occurred, improving the visualization and evaluation of intra-organ vascularity, resulting from enhancements in delineation of tissue detail through electronic compounding and harmonics, as well as enhancements in signal processing of frequency- and/or amplitude-based color Doppler sonography. Spatial representation of vascularity can be improved by utilizing 3D and 4D (live 3D) processing. Greater sensitivity of color Doppler sonography to macro- and microvascular flow has provided improved anatomic and physiologic assessment throughout pregnancy and for pelvic organs. The potential use of contrast enhancement is also mentioned as a means to further differentiate benign from malignant ovarian lesions. The rapid development of these new sonographic techniques will continue to enlarge the scope of clinical applications in a variety of obstetric and gynecologic disorders.

  8. MP3 compression of Doppler ultrasound signals.

    PubMed

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  9. The EVE Doppler Sensitivity and Flare Observations

    NASA Technical Reports Server (NTRS)

    Hudson, H. S.; Woods, T. N.; Chamberlin, P. C.; Didkovsky, L.; Del Zanna, G.

    2011-01-01

    The Extreme-ultraviolet Variability Experiment (EVE) obtains continuous EUV spectra of the Sun viewed as a star. Its primary objective is the characterization of solar spectral irradiance, but its sensitivity and stability make it extremely interesting for observations of variability on time scales down to the limit imposed by its basic 10 s sample interval. In this paper we characterize the Doppler sensitivity of the EVE data. We find that the 30.4 nm line of He II has a random Doppler error below 0.001 nm (1 pm, better than 10 km/s as a redshift), with ample stability to detect the orbital motion of its satellite, the Solar Dynamics Observatory (SDO). Solar flares also displace the spectrum, both because of Doppler shifts and because of EVE's optical layout, which (as with a slitless spectrograph) confuses position and wavelength. As a flare develops, the centroid of the line displays variations that reflect Doppler shifts and therefore flare dynamics. For the impulsive phase of the flare SOL2010-06-12, we find the line centroid to have a redshift of 16.8 +/- 5.9 km/s relative to that of the flare gradual phase (statistical errors only). We find also that high-temperature lines, such as Fe XXIV 19.2 nm, have well-determined Doppler components for major flares, with decreasing apparent blueshifts as expected from chromospheric evaporation flows.

  10. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    PubMed Central

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-01-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe. PMID:27578317

  11. The EVE Doppler Sensitivity and Flare Observations

    NASA Technical Reports Server (NTRS)

    Hudson, H. S.; Woods, T. N.; Chamberlin, P. C.; Didkovsky, L.; Del Zanna, G.

    2011-01-01

    The Extreme-ultraviolet Variability Experiment (EVE) obtains continuous EUV spectra of the Sun viewed as a star. Its primary objective is the characterization of solar spectral irradiance, but its sensitivity and stability make it extremely interesting for observations of variability on time scales down to the limit imposed by its basic 10 s sample interval. In this paper we characterize the Doppler sensitivity of the EVE data. We find that the 30.4 nm line of He II has a random Doppler error below 0.001 nm (1 pm, better than 10 km/s as a redshift), with ample stability to detect the orbital motion of its satellite, the Solar Dynamics Observatory (SDO). Solar flares also displace the spectrum, both because of Doppler shifts and because of EVE's optical layout, which (as with a slitless spectrograph) confuses position and wavelength. As a flare develops, the centroid of the line displays variations that reflect Doppler shifts and therefore flare dynamics. For the impulsive phase of the flare SOL2010-06-12, we find the line centroid to have a redshift of 16.8 +/- 5.9 km/s relative to that of the flare gradual phase (statistical errors only). We find also that high-temperature lines, such as Fe XXIV 19.2 nm, have well-determined Doppler components for major flares, with decreasing apparent blueshifts as expected from chromospheric evaporation flows.

  12. Spacecraft Doppler Tracking as a Xylophone Detector

    NASA Technical Reports Server (NTRS)

    Tinto, Massimo

    1996-01-01

    We discuss spacecraft Doppler tracking in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. By using the four-link radio system first proposed by Vessot and Levine, we derive a new method for removing from the combined data the frequency fluctuations due to the Earth troposphere, ionosphere, and mechanical vibrations of the antenna on the ground. Our method provides also for reducing by several orders of magnitude, at selected Fourier components, the frequency fluctuations due to other noise sources, such as the clock on board the spacecraft or the antenna and buffeting of the probe by non-gravitational forces. In this respect spacecraft Doppler tracking can be regarded as a xylophone detector. Estimates of the sensitivities achievable by this xylophone are presented for two tests of Einstein's theory of relativity: searches for gravitational waves and measurements of the gravitational red shift. This experimental technique could be extended to other tests of the theory of relativity, and to radio science experiments that rely on high-precision Doppler measurements.

  13. Doppler Imaging of Exoplanets and Brown Dwarfs

    NASA Astrophysics Data System (ADS)

    Crossfield, I.; Biller, B.; Schlieder, J.; Deacon, N.; Bonnefoy, M.; Homeier, D.; Allard, F.; Buenzli, E.; Henning, T.; Brandner, W.; Goldman, Bertr; Kopytova, T.

    2014-03-01

    Doppler Imaging produces 2D global maps. When applied to cool planets or more massive brown dwarfs, it can map atmospheric features and track global weather patterns. The first substellar map, of the 2pc-distant brown dwarf Luhman 16B (Crossfeld et al. 2014), revealed patchy regions of thin & thick clouds. Here, I investigate the feasibility of future Doppler Imaging of additional objects. Searching the literature, I find that all 3 of P, v sin i, and variability are published for 22 brown dwarfs. At least one datum exists for 333 targets. The sample is very incomplete below ~L5; we need more surveys to find the best targets for Doppler Imaging! I estimate limiting magnitudes for Doppler Imaging with various hi-resolution near-infrared spectrographs. Only a handful of objects - at the M/L and L/T transitions - can be mapped with current tools. Large telescopes such as TMT and GMT will allow Doppler Imaging of many dozens of brown dwarfs and the brightest exoplanets. More targets beyond type L5 likely remain to be found. Future observations will let us probe the global atmospheric dynamics of many diverse objects.

  14. Doppler estimation accuracy of linear FM waveforms

    NASA Astrophysics Data System (ADS)

    Daum, F. E.

    The single-pulse Doppler estimation accuracy of an unweighted linear FM waveform is analyzed in detail. Simple formulas are derived that predict that one-sigma Doppler estimation error for realistic radar applications. The effects of multiple target interference and nonlinearlities in the radar measurements are considered. In addition, a practical method to estimate Doppler frequency is presented. This technique uses the phase data after pulse compression, and it limits the effect of multiple target interference. In contrast, the available literature is based on the Cramer-Rao bound for Doppler accuracy, which ignores the effects of nonlinearities, multiple target interference and the question of practical implementation. A simple formula is derived that predicts the region of validity for the Cramer-Rao bound. This formula provides a criterion for minimum signal-to-noise ratio in terms of time-bandwidth product. Finally, an important concept that is demonstrated in this paper is that: the bulk of the Doppler information in a linear FM pulse is encoded in the range sidelobes after pulse compression.

  15. Doppler-corrected differential detection of MPSK

    NASA Technical Reports Server (NTRS)

    Simon, Marvin K.; Divsalar, Dariush

    1989-01-01

    An open-loop technique is presented for estimating and correcting Doppler frequency shift in an M-ary differential phase-shift-keyed (MDPSK) receiver. The novelty of the scheme is based on the observation that whereas the change in phase of the received signal over a full symbol contains the sum of the data (phase) and the Doppler-induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler-induced phase shift. Thus, by proper processing, the latter can be estimated and removed from the former. Analytical and simulation results are given for the variance of the above estimator, and the error probability performance of the MDPSK receiver is evaluated in the presence of the Doppler correction. Next, the practical considerations associated with the application of this technique on bandlimited Nyquist channels are discussed and incorporated into the final design. It is shown that the receiver can, in the absence of timing jitter, be designed to allow combined Doppler correction and data detection with no penalty due to intersymbol interference (ISI). The effects of ISI due to timing jitter are assessed by computer simulation.

  16. Real-time virtual Doppler ultrasound

    NASA Astrophysics Data System (ADS)

    Khoshniat, Mahdieh; Thorne, Meghan L.; Poepping, Tamie L.; Holdsworth, David W.; Steinman, David A.

    2004-04-01

    Doppler ultrasound (DUS) is widely used to diagnose and plan treatments for vascular diseases, but the relationship between complex blood flow dynamics and the observed DUS signal is not completely understood. In this paper, we demonstrate that Doppler ultrasound can be realistically simulated in a real-time manner via the coupling of a known, previously computed velocity field with a simple model of the ultrasound physics. In the present case a 3D computational fluid dynamics (CFD) model of physiologically pulsatile flow a stenosed carotid bifurcation was interrogated using a sample volume of known geometry and power distribution. Velocity vectors at points within the sample volume were interpolated using a fast geometric search algorithm and, using the specified US probe characteristics and orientation, converted into Doppler shifts for subsequent display as a Doppler spectrogram or color DUS image. The important effect of the intrinsic spectral broadening was simulated by convolving the velocity at each point within the sample volume by a triangle function whose width was proportional to velocity. A spherical sample volume with a Gaussian power distribution was found to be adequate for producing realistic Doppler spectrogram in regions of uniform, jet, and recirculation flow. Fewer than 1000 points seeded uniformly within a radius comprising more than 99% of the total power were required, allowing spectra to be generated from high resolution CFD data at 100Hz frame rates on an inexpensive desktop workstation.

  17. Compression of polyphase codes with Doppler shift

    NASA Astrophysics Data System (ADS)

    Wirth, W. D.

    It is shown that pulse compression with sufficient Doppler tolerance may be achieved with polyphase codes derived from linear frequency modulation (LFM) and nonlinear frequency modulation (NLFM). Low sidelobes in range and Doppler are required especially for the radar search function. These may be achieved by an LFM derived phase coder together with Hamming weighting or by applying a PNL polyphase code derived from NLFM. For a discrete and known Doppler frequency with an expanded and mismatched reference vector a sidelobe reduction is possible. The compression is then achieved without a loss in resolution. A set up for the expanded reference gives zero sidelobes only in an interval around the signal peak or a least square minimization for all range elements. This version may be useful for target tracking.

  18. Doppler experiments with Cassini radio system

    NASA Technical Reports Server (NTRS)

    Comoretto, G.; Bertotti, B.; Iess, L.; Ambrosini, R.

    1992-01-01

    The radio system of the Cassini orbiter will include a K-alpha band downlink channel, mainly intended for telemetry. A K-alpha uplink has also been proposed to allow for a highly accurate gravitational wave experiment. The fourfold increase in frequency will reduce the plasma noise by a factor of 12 and will allow a Doppler accuracy better than 10 exp -15 for time scales of 10 exp 3 - 10 exp 4 s. Extensive Doppler measurements of the gravitational field of Saturn and its satellites can be performed, exploiting the induced change in the velocity of the spacecraft. Possible sources of low-frequency gravitational waves and errors in the Doppler link are discussed.

  19. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    NASA Technical Reports Server (NTRS)

    Roberts, W. T.

    1985-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  20. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    NASA Technical Reports Server (NTRS)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  1. Doppler effect in Schwarzschild and Kerr geometries

    NASA Astrophysics Data System (ADS)

    Radosz, A.; Augousti, A. T.; Ostasiewicz, K.

    2008-03-01

    Calculation of the Doppler shift in general relativity involves contributions of gravitational and kinematical origins and for most metrics or trajectories these contributions are coupled. The exact expression for this Doppler shift may simplify for particular symmetries. Here the specific case for a light signal emitted by a distant inertial observer and received by an in-falling observer in a Schwarzschild geometry is discussed. The resulting expression the Doppler shift is composed of simple factors that can be clearly identified with contributions arising from classical kinematical, special relativistic and general relativistic origins. This result turns out to be more general and it holds for a case of an arbitrary radial in-fall in Schwarzschild geometry and for a particular type of in-fall in the case of a Kerr metric.

  2. Inline Ultrasonic Rheometry by Pulsed Doppler

    SciTech Connect

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  3. Effects of transducer, velocity, Doppler angle, and instrument settings on the accuracy of color Doppler ultrasound.

    PubMed

    Stewart, S F

    2001-04-01

    The accuracy of a commercial color Doppler ultrasound (US) system was assessed in vitro using a rotating torus phantom. The phantom consisted of a thin rubber tube filled with a blood-mimicking fluid, joined at the ends to form a torus. The torus was mounted on a disk suspended in water, and rotated at constant speeds by a motor. The torus fluid was shown in a previous study to rotate as a solid body, so that the actual fluid velocity was dependent only on the motor speed and sample volume radius. The fluid velocity could, thus, be easily compared to the color Doppler-derived velocity. The effects of instrument settings, velocity and the Doppler angle was assessed in four transducers: a 2.0-MHz phased-array transducer designed for cardiac use, a 4.0-MHz curved-array transducer designed for general thoracic use, and two linear transducers designed for vascular use (one 4.0 MHz and one 6.0 MHz). The color Doppler accuracy was found to be significantly dependent on the transducer used, the pulse-repetition frequency and wall-filter frequency, the actual fluid velocity and the Doppler angle (p < 0.001 by analysis of variance). In particular, the phased array and curved array were observed to be significantly more accurate than the two linear arrays. The torus phantom was found to provide a sensitive measure of color Doppler accuracy. Clinicians need to be aware of these effects when performing color Doppler US exams.

  4. Ultrasonographic Doppler Use for Female Reproduction Management.

    PubMed

    Bollwein, Heinrich; Heppelmann, Maike; Lüttgenau, Johannes

    2016-03-01

    Transrectal color Doppler ultrasonography is a useful technique to get new information about physiologic and pathophysiologic alterations of the uterus and ovaries in female cattle. During all reproductive stages characteristic changes in uterine blood flow are observed. Cows with puerperal disturbances show delayed decrease in uterine blood flow in the first few weeks postparturition compared with healthy cows. Measurement of follicular blood flow is used to identify normally developing follicles and predict superovulatory response. Determination of luteal blood is more reliable than B-mode sonography to distinguish between functional and nonfunctional corpora lutea. Color Doppler ultrasonography is a promising tool to improve reproductive management in female cattle.

  5. Laser Doppler distance sensor using phase evaluation.

    PubMed

    Günther, P; Pfister, T; Büttner, L; Czarske, J

    2009-02-16

    This paper presents a novel optical sensor which allows simultaneous measurements of axial position and tangential velocity of moving solid state objects. An extended laser Doppler velocimeter setup is used with two slightly tilted interference fringe systems. The distance to a solid state surface can be determined via a phase evaluation. The phase laser Doppler distance sensor offers a distance resolution of 150 nm and a total position uncertainty below 1 microm. Compared to conventional measurement techniques, such as triangulation, the distance resolution is independent of the lateral surface velocity. This advantage enables precise distance and shape measurements of fast rotating surfaces.

  6. Broad-band acoustic Doppler current profiler

    USGS Publications Warehouse

    Cobb, E.D.

    1993-01-01

    The broad-band acoustic Doppler current profiler is an instrument that determines velocity based on the Doppler principle by reflecting acoustic signals off sediment particles in the water. The instrument is capable of measuring velocity magnitude and direction throughout a water column and of measuring water depth. It is also capable of bottom tracking and can, therefore, keep track of its own relative position as it is moved across a channel. Discharge measurements can be made quickly and, based on limited tests, accurately with this instrument. ?? 1993.

  7. Laser Doppler Velocimeter particle velocity measurement system

    SciTech Connect

    Wilson, W.W.; Srikantaiah, D.V.; Philip, T.; George, A.

    1993-10-01

    This report gives a detailed description of the operation of the Laser Doppler Velocimeter (LDV) system maintained by DIAL at MSU. LDV is used for the measurement of flow velocities and turbulence levels in various fluid flow settings. Ills report details the operation and maintenance of the LDV system and provides a first-time user with pertinent information regarding the system`s setup for a particular application. Particular attention has been given to the use of the Doppler signal analyzer (DSA) and the burst spectrum analyzer (BSA) signal processors and data analysis.

  8. Laser Doppler velocimeter aerial spray measurements

    NASA Technical Reports Server (NTRS)

    Zalay, A. D.; Eberle, W. R.; Howle, R. E.; Shrider, K. R.

    1978-01-01

    An experimental research program for measuring the location, spatial extent, and relative concentration of airborne spray clouds generated by agricultural aircraft is described. The measurements were conducted with a ground-based laser Doppler velocimeter. The remote sensing instrumentation, experimental tests, and the results of the flight tests are discussed. The cross section of the aerial spray cloud and the observed location, extent, and relative concentration of the airborne particulates are presented. It is feasible to use a mobile laser Doppler velocimeter to track and monitor the transport and dispersion of aerial spray generated by an agricultural aircraft.

  9. Velocity precision measurements using laser Doppler anemometry

    NASA Astrophysics Data System (ADS)

    Dopheide, D.; Taux, G.; Narjes, L.

    1985-07-01

    A Laser Doppler Anemometer (LDA) was calibrated to determine its applicability to high pressure measurements (up to 10 bars) for industrial purposes. The measurement procedure with LDA and the experimental computerized layouts are presented. The calibration procedure is based on absolute accuracy of Doppler frequency and calibration of interference strip intervals. A four-quadrant detector allows comparison of the interference strip distance measurements and computer profiles. Further development of LDA is recommended to increase accuracy (0.1% inaccuracy) and to apply the method industrially.

  10. Laser Doppler And Range Systems For Spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, P. W.; Gagliardi, R. M.

    1990-01-01

    Report discusses two types of proposed laser systems containing active transponders measuring distance (range) and line-of-sight velocity (via Doppler effect) between deep space vehicle and earth-orbiting satellite. Laser system offers diffraction advantage over microwave system. Delivers comparable power to distant receiver while using smaller transmitting and receiving antennas and less-powerful transmitter. Less subject to phase scintillations caused by passage through such inhomogeneous media as solar corona. One type of system called "incoherent" because range and Doppler measurements do not require coherence with laser carrier signals. Other type of system called "coherent" because successful operation requires coherent tracking of laser signals.

  11. Development of Doppler Global Velocimeter (DGV)

    DTIC Science & Technology

    1998-05-01

    Dissertation, Wichita State University, May, 1995. Q«M?7 A301 ’ E’ a’IdI MilleI’ L; S-’ "Eva,uation of a Basic Doppler Global Velocimetry System," SAE...200 words) A two-component Doppler Global Velocimeter (DGV) and a two-component Point Doppier Velocimeter (PDV) are descried Velocity measurements...for both systems to quantify accuracy are presented. Results are presented for velocity distributions over the surface of a rotating wheel and fully

  12. Photoacoustic Doppler flow measurement in optically scattering media

    NASA Astrophysics Data System (ADS)

    Fang, Hui; Maslov, Konstantin; Wang, Lihong V.

    2007-12-01

    We recently observed the photoacoustic Doppler effect from flowing small light-absorbing particles. Here, we apply the effect to measure blood-mimicking fluid flow in an optically scattering medium. The light scattering in the medium decreases the amplitude of the photoacoustic Doppler signal but does not affect either the magnitude or the directional discrimination of the photoacoustic Doppler shift. This technology may hold promise for a new Doppler method for measuring blood flow in microcirculation with high sensitivity.

  13. Acoustic micro-Doppler radar for human gait imaging.

    PubMed

    Zhang, Zhaonian; Pouliquen, Philippe O; Waxman, Allen; Andreou, Andreas G

    2007-03-01

    A portable acoustic micro-Doppler radar system for the acquisition of human gait signatures in indoor and outdoor environments is reported. Signals from an accelerometer attached to the leg support the identification of the components in the measured micro-Doppler signature. The acoustic micro-Doppler system described in this paper is simpler and offers advantages over the widely used electromagnetic wave micro-Doppler radars.

  14. Atmospheric laser Doppler velocimetry - An overview

    NASA Technical Reports Server (NTRS)

    Bilbro, J. W.

    1980-01-01

    Research, development, and application of atmospheric laser Doppler velocimetry are overviewed. Consideration is given to operation principles of CO2 heterodyne systems. Global wind, pollution, V/STOL flow, and true airspeed measurements are outlined. Wind energy, dust devils, water spouts, tornadoes, and aircraft wake vortices are covered.

  15. Tissue Doppler imaging in cardiac sarcoidosis.

    PubMed

    Smedema, J P

    2008-07-01

    A middle-aged African lady, who presented with ventricular tachycardias, mitral valve regurgitation and congestive heart failure, was diagnosed with cardiac sarcoidosis. Tissue Doppler imaging demonstrated abnormalities suggestive of myocardial scar, which was confirmed by contrast-enhanced cardiac magnetic resonance.

  16. Method for Canceling Ionospheric Doppler Effect

    NASA Technical Reports Server (NTRS)

    Vessot, R. F. C.

    1982-01-01

    Unified transponder system with hydrogen-maser oscillators at both stations can compensate for both motional and ionospheric components of Doppler shift. Appropriate choices of frequency shift in output of mixer m3. System exploits proportionality between dispersive component of frequency shift and reciprocal of frequency to achieve cancellation of dispersive component at output.

  17. Calculating "g" from Acoustic Doppler Data

    ERIC Educational Resources Information Center

    Torres, Sebastian; Gonzalez-Espada, Wilson J.

    2006-01-01

    Traditionally, the Doppler effect for sound is introduced in high school and college physics courses. Students calculate the perceived frequency for several scenarios relating a stationary or moving observer and a stationary or moving sound source. These calculations assume a constant velocity of the observer and/or source. Although seldom…

  18. Satellite Doppler data processing using a microcomputer

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.; Lynn, J. J.

    1977-01-01

    A microcomputer which was developed to compute ground radio beacon position locations using satellite measurements of Doppler frequency shift is described. Both the computational algorithms and the microcomputer hardware incorporating these algorithms were discussed. Results are presented where the microcomputer in conjunction with the NIMBUS-6 random access measurement system provides real time calculation of beacon latitude and longitude.

  19. Acoustic Doppler discharge-measurement system

    USGS Publications Warehouse

    Simpson, Michael R.; Oltmann, Richard N.; ,

    1990-01-01

    A discharge-measurement system that uses a vessel-mounted acoustic Doppler current profiler has been developed and tested by the U.S. Geological Survey. Discharge measurements using the system require a fraction of the time needed for conventional current-meter discharge measurements and do not require shore-based navigational aids or tag lines for positioning the vessel.

  20. Thyroid Doppler US: Tips and tricks.

    PubMed

    Lacout, Alexis; Chevenet, Carole; Salas, Joël; Marcy, Pierre Yves

    2016-04-01

    Incidental diagnosis of thyroid nodules is very common on adult neck ultrasonography (US) examination. They are primarily assessed on size and greyscale ultrasound criteria such as hypoechogenicity, taller than wide, spiculated margins and calcifications. In difficult situations Doppler US features may improve tumour characterisation and staging. © 2015 The Royal Australian and New Zealand College of Radiologists.

  1. Investigations of Near-Zone Doppler Effects.

    NASA Astrophysics Data System (ADS)

    Prouty, Dale Austen

    Far away from an electromagnetic source the normal Doppler shifts in frequency occur--a red shift for receding and a blue shift for approaching. As indicated by previous work with an infinitesimal dipole, different frequency shifts occur when the source and observer move closer together, into the near-zone. These "near-zone Doppler effects" are investigated for general sources and subsequently two specific examples are presented. The general results show that near-zone shifts are similar to far-zone shifts, but the local phase velocity must be used, i.e. (DIAGRAM, TABLE OR GRAPHIC OMITTED...PLEASE SEE DAI). In the far zone the phase velocity is the speed of light; in the near zone it differs. Fundamentally, the distance between surfaces of constant phase in the near zone is changed. The surfaces of constant phase for the waves are no longer spherical, but more ellipsoidal or spheroidal, so that a moving observer sees a different frequency shift. Two specific examples are presented to indicate the actual magnitude of near-zone effects. The examples include a prolate spheroidal antenna and a circular aperture. Once the magnitude of the effects is determined, the measurability of near-zone Doppler effects is discussed. The investigation concentrates on Fresnel zone effects due to the measurement problem. Finally, it is shown that for an electrically large wire antenna (the spheroidal example) near-zone Doppler effects are measurable.

  2. Adaptive Spectral Envelope Estimation for Doppler Ultrasound.

    PubMed

    Kathpalia, Aditi; Karabiyik, Yucel; Eik-Nes, Sturla; Tegnander, Eva; Ekroll, Ingvild; Kiss, Gabriel; Torp, Hans

    2016-07-07

    Estimation of accurate maximum velocities and spectral envelope in ultrasound Doppler blood flow spectrograms are both essential for clinical diagnostic purposes. However, obtaining accurate maximum velocity is not straightforward due to intrinsic spectral broadening and variance in the power spectrum estimate. The method proposed in this work for maximum velocity point detection has been developed by modifying an existing method - Signal Noise Slope Intersection (SNSI), incorporating in it steps from an altered version of another method called Geometric Method (GM). Adaptive noise estimation from the spectrogram ensures that a smooth spectral envelope is obtained post detection of these maximum velocity points. The method has been tested on simulated Doppler signal with scatterers possessing a parabolic flow velocity profile constant in time, steady and pulsatile string phantom recordings as well as in vivo recordings from uterine, umbilical, carotid and subclavian arteries. Results from simulation experiments indicate a bias of less than 2.5% in maximum velocities when estimated for a range of peak velocities, Doppler angles and SNR levels. Standard deviation in the envelope is low - less than 2% in case of experiments done by varying the peak velocity and Doppler angle for steady phantom and simulated flow; and also less than 2% in case of experiments done by varying SNR but keeping constant flow conditions for in vivo and simulated flow. Low variability in the envelope makes the prospect of using the envelope for automated blood flow measurements possible and is illustrated for the case of Pulsatility Index estimation in uterine and umbilical arteries.

  3. Rubidium Atomic Line Filtered (RALF) Doppler Velocimetry

    NASA Astrophysics Data System (ADS)

    Fajardo, Mario; Molek, Christopher; Vesely, Annamaria

    2015-06-01

    We report the successful proof-of-concept demonstration of the Rubidium Atomic Line Filtered (RALF) Doppler velocimetry technique. RALF is a high-velocity and high-acceleration adaptation of the Global Doppler Velocimetry (GDV) method developed in the 1990s by aerodynamics researchers. Laser velocimetry techniques in common use within the shock physics community (e . g . VISAR, Fabry-Perot, PDV) decode the Doppler shift of light reflected from a moving surface via interference phenomena. In contrast, RALF employs a completely different physical principle: the frequency-dependent near-resonant optical transmission of a Rb/N2 gas cell, to convert the Doppler shift of reflected λ0 ~ 780.24 nm light directly into transmitted light intensity. The single-point RALF apparatus used in these experiments is fiber optic based, and incorporates a simultaneous PDV measurement channel as an ``internal standard'' for validation of the RALF results. Future plans include ``line-RALF'' experiments with streak camera detection, and two-dimensional surface velocity mapping using pulsed laser illumination and gated intensified CCD camera detection. [RW PA#4931

  4. Measurement of aortic regurgitation by Doppler echocardiography.

    PubMed Central

    Zhang, Y; Nitter-Hauge, S; Ihlen, H; Rootwelt, K; Myhre, E

    1986-01-01

    In an attempt to develop a new approach to the non-invasive measurement of aortic regurgitation, transmitral volumetric flow (MF) and left ventricular total stroke volume (SV) were measured by Doppler and cross sectional echocardiography in 23 patients without aortic valve disease (group A) and in 26 patients with aortic regurgitation (group B). The transmitral volumetric flow was obtained by multiplying the corrected mitral orifice area by the diastolic velocity integral, and the left ventricular total stroke volume was derived by subtracting the left ventricular end systolic volume from the end diastolic volume. The aortic regurgitant fraction (RF) was calculated as: RF = 1 - MF/SV. In group A there was a close agreement between the transmitral volumetric flow and the left ventricular total stroke volume, and the difference between the two measurements did not differ significantly from zero. In group B the left ventricular total stroke volume was significantly larger than the transmitral volumetric flow, and there was good agreement between the regurgitant fractions determined by Doppler echocardiography and radionuclide ventriculography. Discrepancies between the two techniques were found in patients with combined aortic and mitral regurgitation or a low angiographic left ventricular ejection fraction (less than 35%). The effective cardiac output measured by Doppler echocardiography accorded well with that measured by the Fick method. Doppler echocardiography provides a new and promising approach to the non-invasive measurement of aortic regurgitation. PMID:3947478

  5. Tissue Doppler imaging reproducibility during exercise.

    PubMed

    Bougault, V; Nottin, S; Noltin, S; Doucende, G; Obert, P

    2008-05-01

    Tissue Doppler imaging (TDI) is an echocardiographic technique used during exercising to improve the accuracy of a cardiovascular diagnostic. The validity of TDI requires its reproducibility, which has never been challenged during moderate to maximal intensity exercising. The present study was specifically designed to assess the transmitral Doppler and pulsed TDI reproducibility in 19 healthy men, who had undergone two identical semi-supine maximal exercise tests on a cycle ergometer. Systolic (S') and diastolic (E') tissue velocities at the septal and lateral walls as well as early transmitral velocities (E) were assessed during exercise up to maximal effort. The data were compared between the two tests at 40 %, 60 %, 80 % and 100 % of maximal aerobic power. Despite upper body movements and hyperventilation, good quality echocardiographic images were obtained in each case. Regardless of exercise intensity, no differences were noticed between the two tests for all measurements. The variation coefficients for Doppler variables ranged from 3 % to 9 % over the transition from rest to maximal exercise. The random measurement error was, on average, 5.8 cm/s for E' and 4.4 cm/s for S'. Overall, the reproducibility of TDI was acceptable. Tissue Doppler imaging can be used to accurately evaluate LV diastolic and/or systolic function for this range of exercise intensity.

  6. Calculating "g" from Acoustic Doppler Data

    ERIC Educational Resources Information Center

    Torres, Sebastian; Gonzalez-Espada, Wilson J.

    2006-01-01

    Traditionally, the Doppler effect for sound is introduced in high school and college physics courses. Students calculate the perceived frequency for several scenarios relating a stationary or moving observer and a stationary or moving sound source. These calculations assume a constant velocity of the observer and/or source. Although seldom…

  7. Reference values for pulse wave Doppler and tissue Doppler imaging in pediatric echocardiography.

    PubMed

    Dallaire, Frederic; Slorach, Cameron; Hui, Wei; Sarkola, Taisto; Friedberg, Mark K; Bradley, Timothy J; Jaeggi, Edgar; Dragulescu, Andreea; Har, Ronnie L H; Cherney, David Z I; Mertens, Luc

    2015-02-01

    In pediatric echocardiography, pulse wave Doppler, and tissue Doppler imaging velocities are widely used to assess cardiac function. Current reference values and Z scores, allowing adjustment for growth are limited by inconsistent methodologies and small sample size. Using a standardized approach for parametric modeling and Z score quality assessment, we propose new pediatric reference values and Z score equations for most left ventricular pulse wave Doppler and tissue Doppler imaging measurements. Two hundred thirty-three healthy pediatric subjects 1 to 18 years of age were prospectively recruited. Thirteen pulse wave Doppler and 14 tissue Doppler imaging measurements were recorded. Normalization for growth was done via a complete and standardized approach for parametric nonlinear regression modeling. Several analyses were performed to ensure adequate Z score distribution and to detect potential residual associations with growth or residual heteroscedasticity. Most measurements adopted a nonlinear relationship with growth and displayed significant heteroscedasticity. Compared with age, height, and weight, normalization for body surface area was most efficient in removing the effect of growth. Generally, polynomial and allometric models yielded adequate goodness-of-fit. Residual values for several measurements had significant departure from the normal distribution, which could be corrected using logarithmic or reciprocal transformation. Overall, weighted parametric nonlinear models allowed us to compute Z score equations with adequate normal distribution and without residual association with growth. We present Z scores for normalized pulse wave Doppler and tissue Doppler imaging in pediatric echocardiography. Further studies are needed to define the threshold beyond which health becomes a disease by integrating other important factors such as ventricular morphology, loading conditions, and heart rate. © 2015 American Heart Association, Inc.

  8. Rubidium atomic line filtered (RALF) Doppler velocimetry

    NASA Astrophysics Data System (ADS)

    Fajardo, Mario E.; Molek, Christopher D.; Vesely, Annamaria L.

    2017-01-01

    We report recent improvements to our Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus [M.E. Fajardo, C.D. Molek, and A.L. Vesely, J. Appl. Phys. 118, 144901 (2015)]. RALF is a high-velocity and high-acceleration adaptation of the Doppler Global Velocimetry method for measuring multi-dimensional velocity vector flow fields, which was developed in the 1990s by aerodynamics researchers [H. Komine, U.S. Patent #4,919,536]. Laser velocimetry techniques in common use within the shock physics community (e.g. VISAR, Fabry-Pérot, PDV) decode the Doppler shift of light reflected from a moving surface via interference phenomena. In contrast, RALF employs a completely different physical principle: the frequency-dependent near-resonant optical transmission of a Rb/N2 gas cell, to encode the Doppler shift of reflected λ0 ≈ 780.24 nm light directly onto the transmitted light intensity. Thus, RALF is insensitive to minor changes to the optical pathlengths and transit times of the Doppler shifted light, which promises a number of practical advantages in imaging velocimetry applications. The single-point RALF proof-of-concept apparatus described here is fiber optic based, and our most recent modifications include the incorporation of a larger bandwidth detection system, and a second 780 nm laser for simultaneous upshifted-PDV (UPDV) measurements. We report results for the laser driven launch of a 10-μm-thick aluminum flyer which show good agreement between the RALF and UPDV velocity profiles, within the limitations of the admittedly poor signal:noise ratio (SNR) RALF data.

  9. A MAGNETIC CALIBRATION OF PHOTOSPHERIC DOPPLER VELOCITIES

    SciTech Connect

    Welsch, Brian T.; Fisher, George H.; Sun, Xudong

    2013-03-10

    The zero point of measured photospheric Doppler shifts is uncertain for at least two reasons: instrumental variations (from, e.g., thermal drifts); and the convective blueshift, a known correlation between intensity and upflows. Accurate knowledge of the zero point is, however, useful for (1) improving estimates of the Poynting flux of magnetic energy across the photosphere, and (2) constraining processes underlying flux cancellation, the mutual apparent loss of magnetic flux in closely spaced, opposite-polarity magnetogram features. We present a method to absolutely calibrate line-of-sight (LOS) velocities in solar active regions (ARs) near disk center using three successive vector magnetograms and one Dopplergram coincident with the central magnetogram. It exploits the fact that Doppler shifts measured along polarity inversion lines (PILs) of the LOS magnetic field determine one component of the velocity perpendicular to the magnetic field, and optimizes consistency between changes in LOS flux near PILs and the transport of transverse magnetic flux by LOS velocities, assuming that ideal electric fields govern the magnetic evolution. Previous calibrations fitted the center-to-limb variation of Doppler velocities, but this approach cannot, by itself, account for residual convective shifts at the limb. We apply our method to vector magnetograms of AR 11158, observed by the Helioseismic and Magnetic Imager aboard the Solar Dynamics Observatory, and find clear evidence of offsets in the Doppler zero point in the range of 50-550 m s{sup -1}. In addition, we note that a simpler calibration can be determined from an LOS magnetogram and Dopplergram pair from the median Doppler velocity among all near-disk-center PIL pixels. We briefly discuss shortcomings in our initial implementation, and suggest ways to address these. In addition, as a step in our data reduction, we discuss the use of temporal continuity in the transverse magnetic field direction to correct apparently

  10. The Novel Nonlinear Adaptive Doppler Shift Estimation Technique and the Coherent Doppler Lidar System Validation Lidar

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.

    2006-01-01

    The signal processing aspect of a 2-m wavelength coherent Doppler lidar system under development at NASA Langley Research Center in Virginia is investigated in this paper. The lidar system is named VALIDAR (validation lidar) and its signal processing program estimates and displays various wind parameters in real-time as data acquisition occurs. The goal is to improve the quality of the current estimates such as power, Doppler shift, wind speed, and wind direction, especially in low signal-to-noise-ratio (SNR) regime. A novel Nonlinear Adaptive Doppler Shift Estimation Technique (NADSET) is developed on such behalf and its performance is analyzed using the wind data acquired over a long period of time by VALIDAR. The quality of Doppler shift and power estimations by conventional Fourier-transform-based spectrum estimation methods deteriorates rapidly as SNR decreases. NADSET compensates such deterioration in the quality of wind parameter estimates by adaptively utilizing the statistics of Doppler shift estimate in a strong SNR range and identifying sporadic range bins where good Doppler shift estimates are found. The authenticity of NADSET is established by comparing the trend of wind parameters with and without NADSET applied to the long-period lidar return data.

  11. Effect of food intake on commonly used pulsed Doppler and tissue Doppler measurements.

    PubMed

    Dencker, Magnus; Björgell, Ola; Hlebowicz, Joanna

    2011-09-01

    This study evaluates the effect of food intake on commonly used pulsed Doppler and tissue Doppler measurements. Twenty-three healthy subjects aged 25.6 ± 4.5 years were investigated. A wide selection of pulsed Doppler and tissue Doppler variables were measured before a standardized meal as well as and 30 and 110 minutes afterwards. The following variables increased significantly (P < 0.05) 30 minutes after food intake: left ventricular stroke volume, left ventricular cardiac output, left ventricular outflow velocity-time integral, peak of early diastolic (E) and late diastolic (A) mitral flow velocities, pulmonary vein peak velocities in systole (S) and in diastole (D), S/D, pulsed tissue Doppler peak systolic velocities, and late diastolic velocities. Deceleration time of E-wave decreased significantly (P < 0.05). The change in measured variables between fasting and 30 minutes after the food intake ranged from 7% to 28%. There were no significant (P > 0.05) changes in E/A, early diastolic tissue Doppler velocities (e'), and E/e'. Most, but not all variables returned to baseline values 110 minutes after food intake. This study shows that food intake affects several echocardiographic variables used to routinely assess diastolic function and hemodynamics. Further studies are warranted in older healthy subjects and in patients with various cardiac diseases to determine whether the findings are reproducible in such populations. © 2011, Wiley Periodicals, Inc.

  12. Preliminary tests of an airborne meteorological pulse Doppler radar

    NASA Astrophysics Data System (ADS)

    Trotter, B. L.; Strauch, R. G.; Frush, C. L.

    1980-05-01

    An X-band Doppler radar in the tail of a WP-3D research aircraft has been used to conduct tests which demonstrate that technology developed for ground-based Doppler radar can be applied to an airborne system. The Doppler spectra of meteorological targets and chaff have been measured with the airborne radar, and these measurements compared favorably with data obtained by wind sensors on the aircraft and with measurements made with a ground-based Doppler radar. This letter describes the airborne Doppler radar and the preliminary test results.

  13. [Echo-Doppler study of musical heart murmurs].

    PubMed

    Boccardi, L; Pennestrì, F; Minardi, G; Di Segni, M; Pucci, E; Biasucci, L M; Loperfido, F; Ferrari, O; Giovannini, E

    1988-04-01

    The origin of systolic or diastolic musical murmurs was investigated by means of echo-doppler examination in 51 patients with various cardiac diseases. In all cases a typical doppler spectrum was identified, showing bi-directional clusters of frequencies which were concentric in systole and parallel in diastole. The doppler audio signal was musical. A similar echo-doppler signal was obtained by a diapason vibrating in isotonic solution. These data allowed us to identify the site of the vibrating cardiac structure causing the typical echo-doppler spectrum and characteristic audio signal.

  14. Practicability of intraoperative microvascular Doppler sonography in aneurysm surgery.

    PubMed

    Firsching, R; Synowitz, H J; Hanebeck, J

    2000-09-01

    Inadvertent narrowing of parent or branching vessels is one major cause of unfavorable outcome from aneurysm surgery. Intraoperative micro-Doppler sonography of arterial brain vessels during surgery for cerebral aneurysms of the anterior circulation was performed in 50 patients and compared retrospectively with 50 patients, who were operated upon without micro-Doppler sonography. Intraoperative micro-Doppler sonography demonstrated the need for repositioning of the clip in 12 instances. Outcome after surgery with micro-Doppler sonography appeared slightly better than without. Micro-Doppler sonography is concluded to be a practicable adjunct to routine aneurysm surgery.

  15. Phase tracking for pulsar navigation with Doppler frequency

    NASA Astrophysics Data System (ADS)

    Xinyuan, Zhang; Ping, Shuai; Liangwei, Huang

    2016-12-01

    Doppler frequency in pulsar navigation is an effect caused by spacecraft and pulsar motion, which would worsen the pulsar navigation accuracy. To describe this influence, we establish the Doppler frequency measurement model based on pulsar timing. With this model, we describe the relationship between the phase estimation performance and the observation time when Doppler frequency exists. To reduce the pulsar navigation error due to the Doppler frequency, we designed the phase tracking loop for the pulsar navigation. The pulsar frequency can be modified before the phase estimation. As a result, the impact of the Doppler frequency could be lessened, and the observation interval lengths can be lengthened to improve the phase estimation performance.

  16. Superharmonic microbubble Doppler effect in ultrasound therapy

    NASA Astrophysics Data System (ADS)

    Pouliopoulos, Antonios N.; Choi, James J.

    2016-08-01

    The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5  ×  104-5  ×  107 microbubbles ml-1) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s-1, prior to the onset of

  17. Superharmonic microbubble Doppler effect in ultrasound therapy.

    PubMed

    Pouliopoulos, Antonios N; Choi, James J

    2016-08-21

    The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5  ×  10(4)-5  ×  10(7) microbubbles ml(-1)) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s(-1), prior to the onset

  18. Superharmonic microbubble Doppler effect in ultrasound therapy

    PubMed Central

    Pouliopoulos, Antonios N; Choi, James J

    2016-01-01

    Abstract The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5  ×  104–5  ×  107 microbubbles ml−1) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75–366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s−1, prior to

  19. Normal Echocardiographic Measurements in a Korean Population Study: Part II. Doppler and Tissue Doppler Imaging

    PubMed Central

    Choi, Jin-Oh; Shin, Mi-Seung; Kim, Mi-Jeong; Jung, Hae Ok; Park, Jeong Rang; Sohn, Il Suk; Kim, Hyungseop; Park, Seong-Mi; Yoo, Nam Jin; Choi, Jung Hyun; Kim, Hyung-Kwan; Cho, Goo-Yeong; Lee, Mi-Rae; Park, Jin-Sun; Shim, Chi Young; Kim, Dae-Hee; Shin, Dae-Hee; Shin, Gil Ja; Shin, Sung Hee; Kim, Kye Hun; Park, Jae-Hyeong; Lee, Sang Yeub; Kim, Woo-Shik

    2016-01-01

    Background Hemodynamic and functional evaluation with Doppler and tissue Doppler study as a part of comprehensive echocardiography is essential but normal reference values have never been reported from Korean normal population especially according to age and sex. Methods Using Normal echOcaRdiographic Measurements in a KoreAn popuLation study subjects, we obtained normal reference values for Doppler and tissue Doppler echocardiography including tricuspid annular velocities according to current guidelines and compared values according to gender and age groups. Results Mitral early diastolic (E) and late diastolic (A) velocity as well as E/A ratio were significantly higher in women compared to those in men. Conversely, mitral peak systolic and late diastolic annular velocity in both septal and lateral mitral annulus were significantly lower in women compared to those in men. However, there were no significant differences in both septal and lateral mitral early diastolic annular (e') velocity between men and women. In both men and women, mitral E velocity and its deceleration time as well as both E/A and E/e' ratio considerably increased with age. There were no significant differences in tricuspid inflow velocities and tricuspid lateral annular velocities between men and women except e' velocity, which was significantly higher in women compared to that in men. However, changes in both tricuspid inflow and lateral annular velocities according to age were similar to those in mitral velocities. Conclusion Since there were significant differences in Doppler and tissue Doppler echocardiographic variables between men and women and changes according to age were even more considerable in both gender groups, normal Doppler echocardiographic values should be differentially applied based on age and sex. PMID:27358707

  20. Intracoronary Doppler: Clinical Application And Future Directions

    NASA Astrophysics Data System (ADS)

    Whitlow, Patrick L.; Raymond, Russell E.; Tuzcu, E. Murat

    1989-08-01

    Because coronary arteriography may underestimate the severity of coronary artery disease, other methods to assess the physiologic significance of a coronary lesion have been sought. Experimental data have confirmed that the ratio of peak flow to resting flow, coronary vasodilator reserve (CVDR), is a quantitative measure of the functional significance of a coronary a stenosis. A 20 MHz pulsed Doppler catheter with a 1 mm outer diameter and an innerlumen for guidewire placement was developed in 1985 and has been used for clinical measurement of CVDR. The technique appears safe, and reliable signals can be obtained in the vast majority of patients studied. Limitations of the technique include possible changes in vessel diameter with delivery of a vasodilator stimulus, possible elevation of baseline flow above normal resting values which would diminish the CVDR, and inability to measure absolute coronary flow. These limitations could be overcome by the development of an intravascular Echo-Doppler device in the future.

  1. Analysis of Doppler measurements of people

    NASA Astrophysics Data System (ADS)

    Tan, Robert; Bender, Robert

    2006-05-01

    With the changing nature of international security it is of interest to the military to use remote sensors to detect and classify people as potential threats. We chose a millimeter wave (MMW) radar as our sensor to collect data on single and small groups of people that were either walking or running to determine how easily they could be detected. This work was done to support the concept of using Ka-band radar to detect people from an airborne platform. Fully-polarimetric Ka-Band radar data was collected of people walking and running at various orientations with respect to the radar. Micro-Doppler analysis reveals Doppler oscillations with time that are characteristic of people at all orientations measured.

  2. Design of a Doppler reflectometer for KSTAR

    SciTech Connect

    Lee, K. D. Nam, Y. U.; Seo, Seong-Heon; Kim, Y. S.

    2014-11-15

    A Doppler reflectometer has been designed to measure the poloidal propagation velocity on the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. It has the operating frequency range of V-band (50-75 GHz) and the monostatic antenna configuration with extraordinary mode (X-mode). The single sideband modulation with an intermediate frequency of 50 MHz is used for the heterodyne measurement with the 200 MHz in-phase and quadrature (I/Q) phase detector. The corrugated conical horn antenna is used to approximate the Gaussian beam propagation and it is installed together with the oversized rectangular waveguides in the vacuum vessel. The first commissioning test of the Doppler reflectometer system on the KSTAR tokamak is planned in the 2014 KSTAR experimental campaign.

  3. Determination of cardiac output by Doppler echocardiography.

    PubMed Central

    Ihlen, H; Amlie, J P; Dale, J; Forfang, K; Nitter-Hauge, S; Otterstad, J E; Simonsen, S; Myhre, E

    1984-01-01

    Cardiac output determined by Doppler echocardiography was compared with that determined by thermodilution at rest and during dobutamine infusion in 10 patients (group A) and by the Fick method at rest in 11 patients (group B). All patients had angina pectoris without valvular heart disease. Maximum spatial blood velocity and cross sectional aortic area were estimated by the Doppler technique and echocardiography. Cardiac output was calculated by multiplying blood velocity by aortic area at various levels in the ascending aorta. The best correlation of cardiac output between the invasive and non-invasive methods was obtained when maximum velocity in the aortic root and the aortic orifice area were used in the calculations. Cardiac output was considerably overestimated when area measurements in the aortic root were used. Images PMID:6689921

  4. Scrotal inflammatory disease: color Doppler US findings.

    PubMed

    Horstman, W G; Middleton, W D; Melson, G L

    1991-04-01

    A study of 45 patients with 51 cases of hemiscrotal inflammatory disease was done to determine the color Doppler ultrasonographic appearance of scrotal inflammatory disorders. The diagnosis was ultimately established by means of appropriate response to antibiotic treatment (47 cases) or surgery (four cases). In all cases, there was evidence of hyperemia: an increased number and concentration of detectable vessels in the affected portion of the scrotum. In 17 cases, the gray scale images were normal, and the only evidence of inflammation was the presence of hypervascularity. Abnormally decreased epididymal vascular resistance was detected in 14 cases of epididymitis; abnormally decreased testicular vascular resistance was detected in six cases of orchitis. Spontaneous venous flow was present in 18 patients. The authors conclude that color Doppler can demonstrate the hyperemic response to scrotal inflammatory disease and that, in the proper clinical setting, it can supplement the gray scale findings and increase diagnostic confidence.

  5. [Color-Doppler semiology in transplanted kidney].

    PubMed

    Rivolta, R; Castagnone, D; Burdick, L; Mandelli, C; Mangiarotti, R

    1993-05-01

    Color-encoded duplex ultrasonography (CEDU) makes a more accurate technique in kidney graft monitoring by combining real-time US with pulsed Doppler studies of renal vasculature. It is a non-invasive and easy technique. Suitable to study the whole renal artery and vein, CEDU also allows the qualitative and quantitative assessment of the intrarenal vasculature and therefore the easy diagnosis of such vessel dysfunctions as arteriovenous fistulas following biopsy. Moreover, Doppler spectral analysis can be used to distinguish among different causes of renal allograft dysfunction--i.e. rejection, cyclosporine nephrotoxicity or acute tubular necrosis. The value of the resistive index for the differential diagnosis is discussed. CEDU allows a more reliable measurement of renal blood flow thanks to the more precise evaluation of renal artery diameter and mean flow velocity.

  6. Doppler-multipath tolerant voice communication

    NASA Astrophysics Data System (ADS)

    Harris, R. M.

    Line of sight communication between high performance aircraft has been found to be subject to a peculiar form of multipath radio wave propagation - Doppler multipath. It degrades analogue voice reception on the standard fit ultrahigh frequency radio, producing low frequency random noise and warbling. Various modifications were carried out on the aircraft's communications system, but the problem remained. All the evidence points to a natural phenomenon. The reported observations are corroborated by theoretical studies and laboratory simulations of multipath radio wave propagation between two points moving relative to a diffusely scattering reflector. Theoretical predictions of Rician fading have explained the disruption of speech transmitted using conventional dsb(am) modulation. This also indicated suppressing the carrier as a radical cure. Double sideband suppressed carrier radios have been developed for airborne evaluation in comparison with standard dsb(am). The air to air flying trials proved the superior performance of the suppressed carrier system under conditions of Doppler multipath.

  7. ROTATIONAL DOPPLER BEAMING IN ECLIPSING BINARIES

    SciTech Connect

    Groot, Paul J.

    2012-01-20

    In eclipsing binaries the stellar rotation of the two components will cause a rotational Doppler beaming during eclipse ingress and egress when only part of the eclipsed component is covered. For eclipsing binaries with fast spinning components this photometric analog of the well-known spectroscopic Rossiter-McLaughlin effect can exceed the strength of the orbital effect. Example light curves are shown for a detached double white dwarf binary, a massive O-star binary and a transiting exoplanet case, similar to WASP-33b. Inclusion of the rotational Doppler beaming in eclipsing systems is a prerequisite for deriving the correct stellar parameters from fitting high-quality photometric light curves and can be used to determine stellar obliquities as well as, e.g., an independent measure of the rotational velocity in those systems that may be expected to be fully synchronized.

  8. Sub miniaturized laser doppler velocimeter sensor

    NASA Technical Reports Server (NTRS)

    Gharib, Morteza (Inventor); Modaress, Darius (Inventor); Taugwalder, Frederic (Inventor)

    2003-01-01

    A miniaturized laser Doppler velocimeter is formed in a housing that is preferably 3 mm in diameter or less. A laser couples light to a first diffractive optical element that is formed on the fiber end. The light is coupled to a lens that also includes a diffractive optical element. The same lens is also used to collect receive light, and receives includes another diffractive optical element to collect that received light.

  9. Doppler Lidar Wind Value-Added Product

    SciTech Connect

    Newsom, R. K.; Sivaraman, C.; Shippert, T. R.; Riihimaki, L. D.

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  10. Doppler, Johann Christian Andreas (1803-53)

    NASA Astrophysics Data System (ADS)

    Murdin, P.

    2000-11-01

    Born in Salzburg, Austria, Doppler studied and taught mathematics in Vienna. On the verge, because of economic hardship, of emigrating to America, he was offered posts in Prague. Despite huge teaching loads, he was able to carry out some research of his own (in the face of complaints of neglect by his students). In 1842 read a paper to the Royal Bohemian Society `On the colored light of the doubl...

  11. Adaptive Spectral Envelope Estimation for Doppler Ultrasound.

    PubMed

    Kathpalia, Aditi; Karabiyik, Yucel; Eik-Nes, Sturla H; Tegnander, Eva; Ekroll, Ingvild Kinn; Kiss, Gabriel; Torp, Hans

    2016-11-01

    Estimation of accurate maximum velocities and spectral envelope in ultrasound Doppler blood flow spectrograms are both essential for clinical diagnostic purposes. However, obtaining accurate maximum velocity is not straightforward due to intrinsic spectral broadening and variance in the power spectrum estimate. The method proposed in this paper for maximum velocity point detection has been developed by modifying an existing method-signal noise slope intersection, incorporating in it steps from an altered version of another method called geometric method. Adaptive noise estimation from the spectrogram ensures that a smooth spectral envelope is obtained postdetection of these maximum velocity points. The method has been tested on simulated Doppler signal with scatterers possessing a parabolic flow velocity profile constant in time, steady and pulsatile string phantom recordings, as well as in vivo recordings from uterine, umbilical, carotid, and subclavian arteries. The results from simulation experiments indicate a bias of less than 2.5% in maximum velocities when estimated for a range of peak velocities, Doppler angles, and SNR levels. Standard deviation in the envelope is low-less than 2% in the case of experiments done by varying the peak velocity and Doppler angle for steady phantom and simulated flow, and also less than 2% in the case of experiments done by varying SNR but keeping constant flow conditions for in vivo and simulated flow. Low variability in the envelope makes the prospect of using the envelope for automated blood flow measurements possible and is illustrated for the case of pulsatility index estimation in uterine and umbilical arteries.

  12. Doppler-Shifted Raman Spectroscopy Measures Flows

    NASA Technical Reports Server (NTRS)

    Exton, Reginald J.; Hillard, Mervin E., Jr.; Lempert, Walter R.; Covell, Peter F.; Miller, David S.

    1990-01-01

    Technique for measuring velocity, static pressure, and translational temperature of flowing molecules by use of stimulated Raman spectroscopy demonstrated in supersonic wind tunnel at NASA Langley Research Center. Nonintrusive, accurate wind-tunnel measurements obtained without seeding flows. Optical equipment for vibration-free Raman doppler velocimetry in wind tunnel includes specially designed retrometer that reduces sensitivity of system to vibrations. This capability very valuable in aerodynamic testing and proves useful in wide variety of laboratory, industrial, and engineering applications.

  13. Volumetric Doppler angle correction for ultrahigh-resolution optical coherence Doppler tomography

    NASA Astrophysics Data System (ADS)

    You, Jiang; Li, Ang; Du, Congwu; Pan, Yingtian

    2017-01-01

    Ultrahigh-resolution optical coherence Doppler tomography (μODT) demonstrates great potential for quantitative blood flow imaging owing to its large field of view and capillary resolution. However, μODT only detects the axial flow velocity and requires Doppler angle correction to retrieve the absolute velocity. Although methods for Doppler angle tracking of single or few large vessels have been reported, a method that enables angle correction of the entire 3D microvascular networks remains a challenge. Here, we present a method based on eigenvalue analysis of 3D Hessian matrix to retrieve the orientation of each tubular vessel. As the algorithm is voxel based, it is suitable for effective tracking of Doppler angle matrix and restoring the absolute flow over the 3D vascular flow networks. We present results on simulation and flow phantom studies to show its efficacy for accurate 3D angle tracking and absolute flow correction. Then, we perform an in vivo validation study on mouse micro-circulatory cerebral blood flow (CBF) networks, which clearly demonstrates the capability of this method for tracking the Doppler angle matrix of the highly complex 3D CBF networks.

  14. Laser Doppler systems in pollution monitoring

    NASA Technical Reports Server (NTRS)

    Miller, C. R.; Sonnenschein, C. M.; Herget, W. F.; Huffaker, R. M.

    1976-01-01

    The paper reports on a program undertaken to determine the feasibility of using a laser Doppler velocimeter (LDV) to measure smoke-stack gas exit velocity, particulate concentration, and mass flow. Measurements made with a CO2 laser Doppler radar system at a coal-burning power plant are compared with in-stack measurements made by a pitot tube. The operational principles of a LDV are briefly described along with the system employed in the present study. Data discussed include typical Doppler spectra from smoke-stack effluents at various laser elevation angles, the measured velocity profile across the stack exit, and the LDV-measured exit velocity as a function of the exit velocity measured by the in-stack instrument. The in-stack velocity is found to be about 14% higher than the LDV velocity, but this discrepancy is regarded as a systematic error. In general, linear relationships are observed between the laser data, the exit velocity, and the particulate concentration. It is concluded that an LDV has the capability of determining both the mass concentration and the mass flow from a power-plant smoke stack.

  15. Velocity variability in ultrasonic Doppler examinations.

    PubMed

    Hadlock, Jean; Beach, Kirk W

    2009-06-01

    Ultrasonic Doppler examination with spectral waveform has been used for the classification and surveillance of carotid artery stenosis for over 25 years. Progression/regression between examinations can be identified with 95% confidence if the velocity measurements change by more than two times the root mean square difference (RMSD) of the repeat measurement. Peak systolic velocity and end diastolic velocity measurements at a Doppler angle of 60 degrees were repeated in 47 carotid examinations. Measurement difference between sonographers and between instruments was tabulated. Root mean square difference was 11 cm/s (RMS%D = 11%) for systolic and 7 cm/s (RMS%D = 21%) for diastolic velocity measurements (excluding one severe stenosis case). Results for differences between sonographers and between instruments were similar to the overall results. In serial arterial studies using this Doppler velocimetry method, a difference exceeding 23 cm/s (21%) systolic, or 14 cm/s (42%) diastolic velocity indicates a significant (2 x RMSD) hemodynamic change.

  16. Phase Doppler droplet sizing: Scattering angle effects

    SciTech Connect

    Ceman, D.L.; O'Hern, T.J.; Rader, D.J.

    1990-01-01

    The phase Doppler technique is an LDV-based method for the nonintrusive, simultaneous measurement of particle size, velocity, and concentration. It is becoming a standard device for measurement of spray droplets in air as well as cavitation nuclei bubbles in water. The Phase Doppler Particle Analyzer (PDPA) is a commercial phase Doppler instrument. Previous calibrations of the PDPA using well-characterized liquid droplets have revealed nonlinearity of the instrument response for droplet diameters less than 20 {mu}m. For many applications, droplet sizing accuracy in the small diameter range is critical. Light scattering calculations performed by the instrument manufacturer suggest two theoretical approaches to improving the instrument response in this size range: optimizing the collection angle and increasing the collection area. The first approach has been tested experimentally. This paper presents size calibrations of the PDPA with the receiver configured at two angles: 30{degree} (the standard configuration) and 70{degree} off-forward axis. The calibration was performed with monodisperse oleic acid droplets in the diameter range 3.7 to 32 {mu}m. As in earlier calibration studies, the 30{degree} configuration resulted in marked nonlinearity in instrument response below 20 {mu}m. Oscillations were still apparent for the 70{degree} configuration, which showed only a modest improvement compared to the response at 30{degree}. 7 refs., 5 figs.

  17. [Color Doppler in breast tumor pathology].

    PubMed

    Balu-Maestro, C; Bruneton, J N; Giudicelli, T; Chauvel, C; Hery, M D

    1991-11-01

    Colour Doppler findings in a series of 63 cases of breast tumours and 19 cases of lymph node enlargements are reported. Colour Doppler signals of abnormal flow are found in 68.5 percent of the cancers, in 42.8 percent of metastatic lymph nodes and in 10 percent of benign lesions. There was bidirectional flow in 80 percent of all the cases. In cases of malignant tumours, the signal was correlated with the size and location of the lesions most often found peripherally. Presently, this technique appears to be of little value in determining whether a primary malignant tumour of the breast is malignant or benign. It does appear to be useful, first to follow-up cancers during initial chemotherapy (partial regression of the signal and of tumour volume) and secondly, in the diagnosis of metastatic lymph nodes with a specificity of 100 percent in our series. Colour Doppler is on the contrary difficult to interprete after conservative treatment of breast cancer because of post-radiotherapy tissue remodelling.

  18. Doppler Lidar for Wind Measurements on Venus

    NASA Technical Reports Server (NTRS)

    Singh, Upendra N.; Emmitt, George D.; Yu, Jirong; Kavaya, Michael J.

    2010-01-01

    NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. The transmitter portion of the transceiver employs the high-pulse-energy, Ho:Tm:LuLiF, partially conductively cooled laser technology developed at NASA Langley. The transceiver is capable of 250 mJ pulses at 10 Hz. It is very similar to the technology envisioned for coherent Doppler lidar wind measurements from Earth and Mars orbit. The transceiver is coupled to the large optics and data acquisition system in the NASA Langley VALIDAR mobile trailer. The large optics consists of a 15-cm off-axis beam expanding telescope, and a full-hemispheric scanner. Vertical and horizontal vector winds are measured, as well as relative backscatter. The data acquisition system employs frequency domain velocity estimation and pulse accumulation. It permits real-time display of the processed winds and archival of all data. This lidar system was recently deployed at Howard University facility in Beltsville, Mary-land, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other sensors will be presented. A simulation and data product for wind measurement at Venus will be presented.

  19. Laser Doppler measurement techniques for spacecraft

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Gagliardi, Robert M.

    1986-01-01

    Two techniques are proposed for using laser links to measure the relative radial velocity of two spacecraft. The first technique determines the relative radial velocity from a measurement of the two-way Doppler shift on a transponded radio-frequency subcarrier. The subcarrier intensity-modulates reciprocating laser beams. The second technique determines the relative radial velocity from a measurement of the two-way Doppler shift on an optical frequency carrier which is transponded between spacecraft using optical Costas loops. The first technique might be used in conjunction with noncoherent optical communications, while the second technique is compatible with coherent optical communications. The first technique simultaneously exploits the diffraction advantage of laser beams and the maturity of radio-frequency phase-locked loop technology. The second technique exploits both the diffraction advantage of laser beams and the large Doppler effect at optical frequencies. The second technique has the potential for greater accuracy; unfortunately, it is more difficult to implement since it involves optical Costas loops.

  20. [Association of Doppler flowmetry with perinatal outcome in patients with oligohydramnios].

    PubMed

    Romero-Gutiérrez, Gustavo; Herrera-Coria, José; Ruiz-Treviño, Armando Saúl

    2014-01-01

    Introducción: el oligohidramnios en ocasiones se asocia a mala evolución perinatal. El objetivo fue determinar la asociación de la flujometría Doppler con la evolución perinatal en pacientes con oligohidramnios. Métodos: se realizó un estudio transversal en el que se analizaron 130 pacientes con embarazo de 30 a 41 semanas con oligohidramnios; se comparó la medición del índice de resistencia de la arteria umbilical por flujometría Doppler y la medición del líquido amniótico. Se hizo un seguimiento postnatal en el que se registró el Apgar y si los pacientes ameritaron cuidados especiales. Se utilizó estadística descriptiva y se calculó la sensibilidad, especificidad, exactitud y los valores predictivos de las pruebas. Resultados: para el oligohidramnios en muerte perinatal se obtuvo sensibilidad, especificidad y exactitud de 100, 0 y 50 %; y para Apgar de 0, 0 y 0 %, respectivamente. El índice de resistencia de la arteria umbilical referente a la muerte perinatal tuvo sensibilidad, especificidad y exactitud de 100, 96 y 98 %, en tanto que en el Apgar los valores fueron de 0, 95 y 47.5 %, respectivamente. Conclusiones: la flujometría Doppler de la arteria umbilical mostró mayor sensibilidad, especificidad y exactitud que la medición del oligohidramnios y la prueba de Apgar para diagnosticar muerte perinatal.

  1. The characteristics of solid etalon Doppler discriminator and transmitter in designing Doppler lidar

    NASA Astrophysics Data System (ADS)

    Kim, Dukhyeon; Cheong, Hae-Du

    2012-11-01

    In this paper, we propose a new type of Doppler discrimination system using an unseeded pulsed Q-switched laser and solid etalon. To substantiate our system, we calculate the transmitting spectral power distribution and discriminator characteristics. In our calculation, we use a 25 mm thick solid etalon with a finesse of 30, as well as a normal pulsed laser with a bandwidth of 1 cm-1. The results reveal that the change in the receiving scattered signal through the discriminator with a given LOS(Line of Sight) wind velocity is more sensitive than a normal iodine metal vapor-based Doppler lidar receiving system. We experimentally verify our suggestion using our Doppler discriminator and transmitter, and confirm that this combination is more sensitive than a metal vapor filter. Moreover, we suggest a more efficient transmitter and a more sensitive double-edge receiving system based on our calculations and experimental results.

  2. Doppler and speckle methods for diagnostics in dentistry

    NASA Astrophysics Data System (ADS)

    Ulyanov, Sergey S.; Lepilin, Alexander V.; Lebedeva, Nina G.; Sedykh, Alexey V.; Kharish, Natalia A.; Osipova, Yulia; Karpovich, Alexander

    2002-02-01

    The results of statistical analysis of Doppler spectra of scattered intensity, obtained from tissues of oral cavity membrane of healthy volunteers, are presented. The dependence of the spectral moments of Doppler signal on cutoff frequency is investigated. Some results of statistical analysis of Doppler spectra, obtained from tooth pulp of patients, are presented. New approach for monitoring of blood microcirculation in orthodontics is suggested. Influence of own noise of measuring system on formation of speckle-interferometric signal is studied.

  3. Applications of Doppler ultrasound in clinical vascular disease

    NASA Technical Reports Server (NTRS)

    Barnes, R. W.; Hokanson, D. E.; Sumner, D. S.; Strandness, D. E., Jr.

    1975-01-01

    Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

  4. Applications of Doppler ultrasound in clinical vascular disease

    NASA Technical Reports Server (NTRS)

    Barnes, R. W.; Hokanson, D. E.; Sumner, D. S.; Strandness, D. E., Jr.

    1975-01-01

    Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

  5. Reexamination of the Doppler effect through Maxwell's equations.

    PubMed

    Guo, Wei; Aktas, Yildirim

    2012-08-01

    In this work, the electric field emitted from a moving source, an electric point dipole, is analyzed for the purpose of illustrating the physics behind the Doppler effect. It is found that if the (translational) motion of the source is nonrelativistic, the Doppler effect is realized in two steps: the motion of the source first causes the dyadic Green function associated with the electric field to acquire an oscillation frequency in the far-field region of the source, and then the frequency leads to the Doppler effect. It is also demonstrated that the Doppler effect is observable only in the far-field region of the source.

  6. Eliminating Doppler Effects in Synthetic-Aperture Radar Optical Processors

    NASA Technical Reports Server (NTRS)

    Constantindes, N. J.; Bicknell, T. J.

    1984-01-01

    Pair of photodetectors generates correction signals. Instrument detects Doppler shifts in radar and corrects processing parameters so ambiguities caused by shifts not manifested as double or overlapping images.

  7. Eliminating Doppler Effects in Synthetic-Aperture Radar Optical Processors

    NASA Technical Reports Server (NTRS)

    Constantindes, N. J.; Bicknell, T. J.

    1984-01-01

    Pair of photodetectors generates correction signals. Instrument detects Doppler shifts in radar and corrects processing parameters so ambiguities caused by shifts not manifested as double or overlapping images.

  8. Christian Doppler is 200 years young.

    PubMed

    Bollinger, Alfred; Partsch, Hugo

    2003-11-01

    Christian Doppler was born 200 years ago in Salzburg, Austria, on November 29, 1803, worked in Prague and Vienna and died 150 years ago in Venice. In an article of eight pages he described the principle, which made him famous. It appeared in 1842 with the exotic title: "On the Coloured Light of the Double Stars and Certain Other Stars of the Heaven". The validity of his principle for velocity measurement was confirmed by trumpet sounds produced on a train moving towards and away from the observer. Around 1960 Japanese scientists suggested that flow velocity in blood vessels could be determined by analysing the difference of frequency between emitted and backscattered ultrasound. Rushmer and coworkers built machines suitable for medicine in Seattle, where Eugene Strandness recognized their potential and applied them in first studies. In 1967 the technique jumped to Europe and started to be used worldwide. Already by using continuous wave ultrasound it was possible to diagnose occlusive disease of neck and limb arteries, venous thrombosis and valvular insufficiency with accuracy. Measurements of postestenotic ankle blood pressure were facilitated by Doppler sensing. Over the years more sophisticated instruments were developed. Pulsed emission of ultrasound waves opened a way to study flow velocity profiles across large vessels. By combining the method with A or B mode ultrasound blood flow could be quantified and finally perfused segments of blood vessels visualized. Duplex scanning in its simple and then in its colour coded version is nowadays the standard non-invasive technique that nobody would like to miss. Vascular territories like intracranial, renal and intestinal arteries can also be explored. For the assessment of microvascular flow in skin and mucosae laser Doppler instruments were introduced.

  9. PRECISE DOPPLER MONITORING OF BARNARD'S STAR

    SciTech Connect

    Choi, Jieun; Marcy, Geoffrey W.; Howard, Andrew W.; Isaacson, Howard; McCarthy, Chris; Fischer, Debra A.; Johnson, John A.; Wright, Jason T.

    2013-02-20

    We present 248 precise Doppler measurements of Barnard's Star (Gl 699), the second nearest star system to Earth, obtained from Lick and Keck Observatories during the 25 years between 1987 and 2012. The early precision was 20 m s{sup -1} but was 2 m s{sup -1} during the last 8 years, constituting the most extensive and sensitive search for Doppler signatures of planets around this stellar neighbor. We carefully analyze the 136 Keck radial velocities spanning 8 years by first applying a periodogram analysis to search for nearly circular orbits. We find no significant periodic Doppler signals with amplitudes above {approx}2 m s{sup -1}, setting firm upper limits on the minimum mass (Msin i) of any planets with orbital periods from 0.1 to 1000 days. Using a Monte Carlo analysis for circular orbits, we determine that planetary companions to Barnard's Star with masses above 2 M {sub Circled-Plus} and periods below 10 days would have been detected. Planets with periods up to 2 years and masses above 10 M {sub Circled-Plus} (0.03 M {sub Jup}) are also ruled out. A similar analysis allowing for eccentric orbits yields comparable mass limits. The habitable zone of Barnard's Star appears to be devoid of roughly Earth-mass planets or larger, save for face-on orbits. Previous claims of planets around the star by van de Kamp are strongly refuted. The radial velocity of Barnard's Star increases with time at 4.515 {+-} 0.002 m s{sup -1} yr{sup -1}, consistent with the predicted geometrical effect, secular acceleration, that exchanges transverse for radial components of velocity.

  10. The feasibility of Doppler monitoring during EVA

    NASA Astrophysics Data System (ADS)

    Barer, A.; Filipenkov, S.; Katuntsev, V.; Vogt, L.; Wenzel, J.

    1995-07-01

    During extravehicular activities (EVA) outside the spacecraft, astronauts have to work under reduced pressure in a space suit. This pressure reduction induces the risk of decompression sickness (DCS) by the formation of gas bubbles from excess nitrogen dissolved in the organism by breathing air at normal pressure. Under laboratory conditions the gas bubbles moving in the blood stream can be detected by the non-invasive ultrasonic Doppler method. By early detection of excessive bubble formation the development of DCS symptoms may be prevented by early application of preventative measures. The method could also be useful when applied in the space suit in order to compare the results of laboratory tests with operational results, because there is a discrepancy according to the DCS risk of laboratory experiments and actual EVA missions, where no symptoms have been reported yet. A prototype Doppler sensor has been developed and implemented in the Russian Orlan suit. To investigate the feasibility of this method under simulated space conditions, the equipment has been used in a series of 12 thermovacuum chamber tests with suited subjects, where intravenous bubble formation was compared to unsuited control experiments. In more than 50% of the suited tests good Doppler recordings could be achieved. In some cases with unsatisfying results the signal could be improved by breathholding. Although the results do not yet allow any conclusion about a possible difference between suited and unsuited subjects due to the small number of tests performed, the method proved its feasibility for use in EVA suits and should be further developed to enhance the safety of EVA procedures.

  11. The feasibility of Doppler monitoring during EVA.

    PubMed

    Barer, A; Filipenkov, S; Katuntsev, V; Vogt, L; Wenzel, J

    1995-07-01

    During extravehicular activities (EVA) outside the spacecraft, astronauts have to work under reduced pressure in a space suit. This pressure reduction induces the risk of decompression sickness (DCS) by the formation of gas bubbles from excess nitrogen dissolved in the organism by breathing air at normal pressure. Under laboratory conditions the gas bubbles moving in the blood stream can be detected by the non-invasive ultrasonic Doppler method. By early detection of excessive bubble formation the development of DCS symptoms may be prevented by early application of preventative measures. The method could also be useful when applied in the space suit in order to compare the results of laboratory tests with operational results, because there is a discrepancy according to the DCS risk of laboratory experiments and actual EVA missions, where no symptoms have been reported yet. A prototype Doppler sensor has been developed and implemented in the Russian Orlan suit. To investigate the feasibility of this method under simulated space conditions, the equipment has been used in a series of 12 thermovacuum chamber tests with suited subjects, where intravenous bubble formation was compared to unsuited control experiments. In more than 50% of the suited tests good Doppler recordings could be achieved. In some cases with unsatisfying results the signal could be improved by breathholding. Although the results do not yet allow any conclusion about a possible difference between suited and unsuited subjects due to the small number of tests performed, the method proved its feasibility for use in EVA suits and should be further developed to enhance the safety of EVA procedures.

  12. [Aortic flow measurement by transesophageal Doppler effect].

    PubMed

    Cathignol, D; Lavandier, B; Muchada, R

    1985-01-01

    Continuous measurement of cardiac output by thermodilution is invasive, impractical and unpleasant for the patient. We propose to measure descending aortic blood flow with a specially designed intra-oesophageal Doppler echo probe. The apparatus is composed of two main parts. First an A scan system makes possible the measurement of the diameter of the vessel, second a continuous wave velocimeter is used to measure the spatial mean velocity of the blood. An output calculator determines the descending aortic blood flow. The oesophageal catheter contains three ultrasonic transducers at its tip mounted on an epoxy resin bracket produced by moulding. They are connected to a flexible hose placed inside a flexible polyvinyl sheath whose outer diameter is 6.8 mm and length is 50 cm. A cylindrical latex balloon is mounted on this sheath which is water inflated to minimum pressure, ensuring a good ultrasonic coupling between the transducers and the oesophageal wall. Connection between the probe and the apparatus is made by three coaxial cables. Three isolator-transformers are built into the connector cable to ensure a safe electrical circuit. After having bled the probe of any air, the balloon is deflated. The probe is gently introduced into the oesophagus by nasal or oral route until the transducers are situated between the 5th and 6th vertebra. The balloon is then inflated to minimum pressure with 10 ml of distilled water contained in a syringe. To find the aorta, the velocimeter is first used like a Doppler stethoscope. The probe is rotated into a position corresponding to the maximum level of Doppler signal.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Current-induced spin wave Doppler shift

    NASA Astrophysics Data System (ADS)

    Bailleul, Matthieu

    2010-03-01

    In metal ferromagnets -namely Fe, Co and Ni and their alloys- magnetism and electrical transport are strongly entangled (itinerant magnetism). This results in a number of properties such as the tunnel and giant magnetoresistance (i.e. the dependence of the electrical resistance on the magnetic state) and the more recently addressed spin transfer (i.e. the ability to manipulate the magnetic state with the help of an electrical current). The spin waves, being the low-energy elementary excitations of any ferromagnet, also exist in itinerant magnets, but they are expected to exhibit some peculiar properties due the itinerant character of the carriers. Accessing these specific properties experimentally could shed a new light on the microscopic mechanism governing itinerant magnetism, which -in turn- could help in optimizing material properties for spintronics applications. As a simple example of these specific properties, it was predicted theoretically that forcing a DC current through a ferromagnetic metal should induce a shift of the frequency of the spin waves [1,2]. This shift can be identified to a Doppler shift undergone by the electron system when it is put in motion by the electrical current. We will show how detailed spin wave measurements allow one to access this current-induced Doppler shift [3]. From an experimental point of view, we will discuss the peculiarities of propagating spin wave spectroscopy experiments carried out at a sub-micrometer length-scale and with MHz frequency resolution. Then, we will discuss the measured value of the Doppler shift in the context of both the old two-current model of spin-polarized transport and the more recent model of adiabatic spin transfer torque. [4pt] [1] P.Lederer and D.L. Mills, Phys.Rev. 148, 542 (1966).[0pt] [2] J. Fernandez-Rossier et al., Phys. Rev. B 69, 174412 (2004)[0pt] [3] V. Vlaminck and M. Bailleul, Science 322, 410 (2008).

  14. Precise Doppler Monitoring of Barnard's Star

    NASA Astrophysics Data System (ADS)

    Choi, Jieun; McCarthy, Chris; Marcy, Geoffrey W.; Howard, Andrew W.; Fischer, Debra A.; Johnson, John A.; Isaacson, Howard; Wright, Jason T.

    2013-02-01

    We present 248 precise Doppler measurements of Barnard's Star (Gl 699), the second nearest star system to Earth, obtained from Lick and Keck Observatories during the 25 years between 1987 and 2012. The early precision was 20 m s-1 but was 2 m s-1 during the last 8 years, constituting the most extensive and sensitive search for Doppler signatures of planets around this stellar neighbor. We carefully analyze the 136 Keck radial velocities spanning 8 years by first applying a periodogram analysis to search for nearly circular orbits. We find no significant periodic Doppler signals with amplitudes above ~2 m s-1, setting firm upper limits on the minimum mass (Msin i) of any planets with orbital periods from 0.1 to 1000 days. Using a Monte Carlo analysis for circular orbits, we determine that planetary companions to Barnard's Star with masses above 2 M ⊕ and periods below 10 days would have been detected. Planets with periods up to 2 years and masses above 10 M ⊕ (0.03 M Jup) are also ruled out. A similar analysis allowing for eccentric orbits yields comparable mass limits. The habitable zone of Barnard's Star appears to be devoid of roughly Earth-mass planets or larger, save for face-on orbits. Previous claims of planets around the star by van de Kamp are strongly refuted. The radial velocity of Barnard's Star increases with time at 4.515 ± 0.002 m s-1 yr-1, consistent with the predicted geometrical effect, secular acceleration, that exchanges transverse for radial components of velocity. Based on observations made at Keck Observatory and Lick Observatory.

  15. Applications of Doppler optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Zhiqiang

    A major development in biomedical imaging in the last decade has been optical coherence tomography (OCT). This technique enables microscale resolution, depth resolved imaging of the detailed morphology of transparent and nontransparent biological tissue in a noncontact and quasi-noninvasive way. In the first part of this dissertation, we will describe the development and the performance of our home-made OCT systems working with different wavelength regions based on free-space and optical fiber Michelson interferometers. The second part will focus on Doppler OCT (DOCT), an important extension of OCT, which enables the simultaneous evaluation of the structural information and of the fluid flow distribution at a localized position beneath the sample surface. Much effort has been spent during the past few years in our laboratory aimed at providing more accurate velocity measurements with an extended dynamic range. We also applied our technique in different research areas such as microfluidics and hemodynamics. Investigations on the optical properties of the biological tissues (such as absorption and scattering) corresponding to different center wavelengths, have been performed in our laboratory. We used a 10 femtosecond Ti:sapphire laser centered at about 810 nm associated with a free-space Michelson interferometer. The infrared sources were centered at about 1310 and 1560 nm with all-fiber interferometers. Comparative studies using three different sources for several in vitro biological tissues based on a graphical method illustrated how the optical properties affect the quality of the OCT images in terms of the penetration depth and backscattering intensity. We have shown the advantage of working with 810-nm emission wavelength for good backscattering amplitude and contrast, while sources emitting at 1570 nm give good penetration depth. The 1330-nm sources provide a good compromise between the two. Therefore, the choice of the source will ultimately determine the

  16. Overview of mesocale research Doppler lidar activities

    NASA Technical Reports Server (NTRS)

    Fitzjarrald, D. E.

    1984-01-01

    In evaluating the performance of the airborne Doppler lidar system, a large number of deficiencies or mistakes were identified in the original system and experiment plans. All of the known problems were addressed and corrected in the planning and engineering for the fall 1984/spring 1985 ADLS flight series. Thus, the most significant result of the data analysis was the input it has provided to the preparations for the new experiment. Attitude measurements are taken together with the streamlined operating procedures, color graphics real time displays of data, and better experiment design, the result is a second-generation system that is considerably better than the one used in 1981.

  17. Transmission media effects on precise Doppler tracking

    NASA Technical Reports Server (NTRS)

    Callahan, P. S.

    1978-01-01

    The effects of the transmission media - the earth's troposphere and ionosphere, and the solar wind - on precise Doppler tracking are discussed. The charged particle effects can be largely removed by dual frequency observations; however there are limitations to these corrections (besides system noise and/or finite integration times) including the effects of magnetic fields, diffraction, and differential refraction, all of which must be carefully evaluated. The earth's troposphere can contribute an error of delta f/f approximately 10 to the minus 14th power.

  18. In-suit Doppler technology assessment

    NASA Astrophysics Data System (ADS)

    Schulze, Arthur E.; Greene, Ernest R.; Nadeau, John J.

    1991-12-01

    The objective of this program was to perform a technology assessment survey of non-invasive air embolism detection utilizing Doppler ultrasound methodologies. The primary application of this technology will be a continuous monitor for astronauts while performing extravehicular activities (EVA's). The technology assessment was to include: (1) development of a full understanding of all relevant background research; and (2) a survey of the medical ultrasound marketplace for expertise, information, and technical capability relevant to this development. Upon completion of the assessment, LSR was to provide an overview of technological approaches and R&D/manufacturing organizations.

  19. Mobile fiber-optic laser Doppler anemometer.

    PubMed

    Stieglmeier, M; Tropea, C

    1992-07-20

    A laser Doppler anemometer (LDA) has been developed that combines the compactness and low power consumption of laser diodes and avalanche photodiodes with the flexibility and possibility of miniaturization by using fiber-optic probes. The system has been named DFLDA for laser diode fiber LDA and is especially suited for mobile applications, for example, in trains, airplanes, or automobiles. Optimization considerations of fiber-optic probes are put forward and several probe examples are described in detail. Measurement results from three typical applications are given to illustrate the use of the DFLDA. Finally, a number of future configurations of the DFLDA concept are discussed.

  20. Wideband infrared receiver backend. [Doppler radar, radiometers

    NASA Technical Reports Server (NTRS)

    Flattau, T.; Mellars, J.

    1974-01-01

    The design, operation, and configuration of the receiver backend for a wideband infrared tracking receiver are described. A squaring loop is incorporated into the receiver design to enable it to track the Doppler shifted carrier which is Phase Shift Keyed modulated. The receiver has a 400 MHz instantaneous bandwidth and tracks signals whose carrier frequency at the backend input is between 200 and 900 MHz with frequency variation rates greater than 20 MHz/second. The output data is compatible with MECL 3 logic.

  1. Doppler Measurements of the Suns Meridional Flow

    NASA Technical Reports Server (NTRS)

    Hathaway, David H.

    1996-01-01

    Doppler velocity data obtained with the Global Oscillation Network Group (GONG) instruments in Tucson from 1992 August through 1995 April were analyzed to determine the structure and evolution of the Sun's meridional flow. Individual measurements of the flow were derived from line-of-sight velocity images averaged over 17 minutes to remove the p-mode oscillation signal. Typical flow velocities are poleward at approximately 20 m/s, but the results suggest that episodes may occur with much stronger flows. Such variations may help to explain some of the many disparate reports on the strength and structure of the Sun's meridional flow.

  2. The new Adelaide medium frequency Doppler radar

    NASA Astrophysics Data System (ADS)

    Reid, I. M.; Vandepeer, B. G. W.; Dillon, S.; Fuller, B.

    1993-08-01

    The Buckland Park Aerial Array (35 deg S, 138 deg E) is situated about 40 km north of Adelaide on a flat coastal plain. It was designed by Basil Briggs and Graham Elford, and constructed between 1965 and 1968. The first results were published in the late 1960's. Some aspects of the history of the array are described in Briggs (1993). A new MF Doppler Radar utilizing the array has been developed. This paper describes some of the technical details of this new facility.

  3. Signal broadening in the laser Doppler velocimeter.

    NASA Technical Reports Server (NTRS)

    Angus, J. C.; Edwards, R. V.; Dunning, J. W., Jr.

    1971-01-01

    Critical review of a recent paper in which Denison, Stevenson, and Fox (1971) discussed the sources of spectral broadening in the laser Doppler velocimeter. It is pointed out that, in their discussion, the above-mentioned authors indicated that the spread in wave vectors of the incident and detected fields and the finite length of time a scattering center stayed in the sample volume each contributed separately and independently to the observed spectral width of the scattered radiation. This statement is termed incorrect, and it is shown that the two effects are one and the same.

  4. Applying Zeeman Doppler imaging to solar spectra

    NASA Astrophysics Data System (ADS)

    Hussain, G. A. J.; Saar, S. H.; Collier Cameron, A.

    2004-03-01

    A new generation of spectro-polarimeters with high throughput (e.g. CFHT/ESPADONS and LBT/PEPSI) is becoming available. This opportunity can be exploited using Zeeman Doppler imaging (ZDI), a technique that inverts time-series of Stokes V spectra to map stellar surface magnetic fields (Semel 1989). ZDI is assisted by ``Least squares deconvolution'' (LSD), which sums up the signal from 1000's of photospheric lines to produce a mean deconvolved profile with higher S:N (Donati & Collier Cameron 1997).

  5. [Color Doppler sonography of focal abdominal lesions].

    PubMed

    Licanin, Zoran; Lincender, Lidija; Djurović, V; Salihefendić, Nizama; Smajlović, Fahrudin

    2004-01-01

    Color Doppler sonography (CDS--spectral, color and power), harmonic imaging techniques (THI, PHI), possibility of 3D analysis of picture, usage of contrast agents, have raised the values of ultrasound as a diagnostic method to a very high level. THI--non-linear gray scale modality, is based on the processing of higher reflected frequencies, that has improved a picture resolution, which is presented with less artifacts and limiting effects of obesity and gases. Ultrasound contrast agents improve analysis of micro and macro circulation of the examined area, and with the assessment of velocity of supply in ROI (wash in), distribution and time of signal weakening (wash out), are significantly increasing diagnostic value of ultrasound. Besides the anatomical and topographic presentation of examined region (color, power), Color Doppler sonography gives us haemodynamic-functional information on vascularisation of that region, as well as on pathologic vascularisation if present. Avascular aspect of a focal pathologic lesion corresponds to a cyst or haematoma, while coloration and positive spectral curve discover that anechogenic lesions actually represents aneurysms, pseudoaneurysms or AVF. In local inflammatory lesion, abscess in an acute phase, CDS shows first increased, and then decreased central perfusion, while in a chronic phase, a pericapsular vascularisation is present. Contribution of CDS in differentiation of hepatic tumors (hemangioma, HCC and metastasis) is very significant. Central color dots along the peripheral blood vessels and the blush phenomenon are characteristics of capillary hemangioma, peritumoral vascular ring "basket" of HCC, and "detour" sign of metastasis. The central artery, RI from 0.45 to 0.60 and radial spreading characterize FNH. Hepatic adenoma is characterized by an intratumoral vein, and rarely by a vascular hallo. Further on, blood velocity in tumor defined by Color Doppler, distinguishes malignant from benign lesion, where 40 cm/s is a

  6. Catadioptric optics for laser Doppler velocimeter applications

    NASA Technical Reports Server (NTRS)

    Dunagan, Stephen E.

    1989-01-01

    This paper examines the adaptation of low-cost Schmidt-Cassegrain astronomical telescopes to perform the laser-beam-focusing and scattered-light collection tasks associated with dual-beam laser Doppler velocimetry. A generic telescope design is analyzed using ray-tracing methods and Gaussian beam-propagation theory. A straightforward modification procedure to convert from infinite to near unity conjugate-ratio operation with very low residual aberration is identified and tested with a 200-mm-aperture telescope modified for f/10 operation. Performance data for this modified telescope configuration are near the diffraction limit and agree well with predictions.

  7. Dealiasing Doppler velocites using edge detection

    NASA Astrophysics Data System (ADS)

    Meech, Scott P.

    This study presents a new algorithm to dealias folded Doppler velocities in S, C, and X-Band radars using a new boundary detection technique on the raw velocity field as a whole, rather than the traditional gate by gate methodology used in more popular and widespread algorithms. Several different types of precipitation events are used to compare and contrast the final output of the new boundary based algorithm. The results are then compared to the NEXRAD dealiasing algorithm as defined by Eilts and Smith (1989) and an objective manual unfolding by radar manipulation software called SoloII.

  8. In-suit Doppler technology assessment

    NASA Technical Reports Server (NTRS)

    Schulze, Arthur E.; Greene, Ernest R.; Nadeau, John J.

    1991-01-01

    The objective of this program was to perform a technology assessment survey of non-invasive air embolism detection utilizing Doppler ultrasound methodologies. The primary application of this technology will be a continuous monitor for astronauts while performing extravehicular activities (EVA's). The technology assessment was to include: (1) development of a full understanding of all relevant background research; and (2) a survey of the medical ultrasound marketplace for expertise, information, and technical capability relevant to this development. Upon completion of the assessment, LSR was to provide an overview of technological approaches and R&D/manufacturing organizations.

  9. Catadioptric optics for laser Doppler velocimeter applications

    NASA Technical Reports Server (NTRS)

    Dunagan, Stephen E.

    1989-01-01

    This paper examines the adaptation of low-cost Schmidt-Cassegrain astronomical telescopes to perform the laser-beam-focusing and scattered-light collection tasks associated with dual-beam laser Doppler velocimetry. A generic telescope design is analyzed using ray-tracing methods and Gaussian beam-propagation theory. A straightforward modification procedure to convert from infinite to near unity conjugate-ratio operation with very low residual aberration is identified and tested with a 200-mm-aperture telescope modified for f/10 operation. Performance data for this modified telescope configuration are near the diffraction limit and agree well with predictions.

  10. Solar Doppler shifts - Sources of continuous spectra

    NASA Technical Reports Server (NTRS)

    Duvall, T. L., Jr.; Harvey, J. W.

    1986-01-01

    Oscillation observations can be used to study nonoscillatory solar phenomena that exhibit Doppler shifts. The paper discusses several effects of these phenomena and their associated temporal and spatial power spectra: (1) they limit the signal-to-noise ratio and sometimes detectability of oscillation modes; (2) there is the potential for better understanding and/or detection of solar phenomena; (3) large-scale convection may spatially modulate oscillation modes, leading to a continuous background spectrum; and (4) in regions of the spectrum where the resolution to separate modes is lacking one can determine upper limits for the integrated effects of modes.

  11. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    PubMed

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-12-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  12. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    PubMed Central

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-01-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: “Gestational trophoblastic disease AND Ultrasonography, Doppler.” Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. 1 Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. 2 There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. 3 Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. 4 Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. CONCLUSION: Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia. PMID:26735221

  13. ALADIN doppler wind lidar: recent advances

    NASA Astrophysics Data System (ADS)

    Morancais, Didier; Fabre, Frédéric; Endemann, Martin; Culoma, Alain

    2007-10-01

    The Atmospheric Laser Doppler Instrument (ALADIN) is the payload of the ADM-Aeolus mission, which will provide direct measurements of global wind fields. It will determine the wind velocity component normal to the satellite velocity vector. The instrument is a direct detection Doppler Lidar operating in the UV, which will be the first of its kind in space. ALADIN comprises a high energy laser and a direct detection receiver operating on aerosol and molecular backscatter signals in parallel. The laser is all solid-state, based on Nd-YAG technology and high power laser diodes. The detector is a silicon CCD whose architecture allows on-chip accumulation of the returns, providing photon counting performance. The 1.5 m diameter telescope is lightweight, all made of silicon carbide. ALADIN is now in its final construction stage: the integration of the Flight Model is on-going. Most of the subsystems have been integrated; the payload performance and qualification test campaign will commence. This paper briefly describes the instrument design and provides insights on the development status and the results obtained so far. This regards in particular the receiver performance, the telescope development and the challenges of the laser. The Aeolus satellite is developed for the European Space Agency by EADS Astrium Satellites as prime contractor for the satellite and the instrument.

  14. Doppler echocardiography in athletes from different sports

    PubMed Central

    Moro, Andre Santos; Okoshi, Marina Politi; Padovani, Carlos Roberto; Okoshi, Katashi

    2013-01-01

    Background Studies have shown cardiac changes induced by intense and regular physical activity. The purpose of this study was to evaluate cardiac structures and function in soccer players, cyclists and long-distance runners, and compare them with non-athlete controls. Material/Methods Cardiac structural, systolic, and diastolic function parameters in 53 athletes and 36 non-athlete controls were evaluated by Doppler echocardiography. Results Athletes presented higher left atrial volume, left ventricular (LV) thickness, and LV and right ventricular (RV) diastolic diameters (LVDD and RVDD, respectively) compared to non-athletes. Left atrium and LVDD were higher in cyclists than runners, and RVDD was higher in cyclists than soccer players. LV mass index was higher in athletes, and cyclists had higher values than runners and soccer players. LV systolic function did not differ significantly between groups. The only altered index of LV diastolic function was a higher E/A ratio in cyclists compared to controls. There was no difference in LV E/E’ ratio. RV systolic function evaluated by tissue Doppler imaging was higher in cyclists and soccer players than runners. There were no conclusive differences in RV diastolic function. Conclusions Soccer players, runners and cyclists had remodeling of left and right ventricular structures compared to controls. Cardiac remodeling was more intense in cyclists than runners and soccer players. PMID:23478754

  15. Fiber Scrambling for Extreme Doppler Precision

    NASA Astrophysics Data System (ADS)

    Spronck, Julien; Kaplan, Z.; Fischer, D.

    2011-09-01

    The detection of Earth-like exoplanets with the radial velocity method requires extreme Doppler precision and long-term stability in order to measure tiny reflex velocities in the host star. Recent planet searches have led to the detection of so called “super-Earths” (up to a few Earth masses) that induce radial velocity changes of about 1 m/s. However, the detection of true Earth analogs requires a precision of 10 cm/s. One of the factors limiting Doppler precision is variation in the Point Spread Function (PSF) from observation to observation due to changes in the illumination of the slit and spectrograph optics. Thus, this stability has become a focus of current instrumentation work. Fiber optics have been used since the 1980’s to couple telescopes to high-precision spectrographs, initially for simpler mechanical design and control. However, fiber optics are also naturally efficient scramblers. Scrambling refers to a fiber’s ability to produce an output beam independent of input. Our research is focused on understanding the scrambling properties of fibers with different geometries (circular, square, octagonal), different lengths and fiber sizes. Another important parameter when it comes to fibers is the so-called focal ratio degradation (FRD), which accounts for a different (faster) focal ratio after the fiber than the one sent into the fiber. In this paper, we will present new insight on fiber scrambling, FRD and what we call fiber personality, which describes differing behaviors for supposedly identical fiber.

  16. Ambiguity resolution for satellite Doppler positioning systems

    NASA Technical Reports Server (NTRS)

    Argentiero, P.; Marini, J.

    1979-01-01

    The implementation of satellite-based Doppler positioning systems frequently requires the recovery of transmitter position from a single pass of Doppler data. The least-squares approach to the problem yields conjugate solutions on either side of the satellite subtrack. It is important to develop a procedure for choosing the proper solution which is correct in a high percentage of cases. A test for ambiguity resolution which is the most powerful in the sense that it maximizes the probability of a correct decision is derived. When systematic error sources are properly included in the least-squares reduction process to yield an optimal solution the test reduces to choosing the solution which provides the smaller valuation of the least-squares loss function. When systematic error sources are ignored in the least-squares reduction, the most powerful test is a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudoinverse of a reduced-rank square matrix. A formula for computing the power of the most powerful test is provided. Numerical examples are included in which the power of the test is computed for situations that are relevant to the design of a satellite-aided search and rescue system.

  17. Micro-Doppler classification of riders and riderless horses

    NASA Astrophysics Data System (ADS)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  18. New Doppler echocardiographic applications for the study of diastolic function

    NASA Technical Reports Server (NTRS)

    Garcia, M. J.; Thomas, J. D.; Klein, A. L.

    1998-01-01

    Doppler echocardiography is one of the most useful clinical tools for the assessment of left ventricular (LV) diastolic function. Doppler indices of LV filling and pulmonary venous (PV) flow are used not only for diagnostic purposes but also for establishing prognosis and evaluating the effect of therapeutic interventions. The utility of these indices is limited, however, by the confounding effects of different physiologic variables such as LV relaxation, compliance and filling pressure. Since alterations in these variables result in changes in Doppler indices of opposite direction, it is often difficult to determine the status of a given variable when a specific Doppler filling pattern is observed. Recently, color M-mode and tissue Doppler have provided useful insights in the study of diastolic function. These new Doppler applications have been shown to provide an accurate estimate of LV relaxation and appear to be relatively insensitive to the effects of preload compensation. This review will focus on the complementary role of color M-mode and tissue Doppler echocardiography and traditional Doppler indices of LV filling and PV flow in the assessment of diastolic function.

  19. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1550 Ultrasonic pulsed doppler...

  20. Doppler weather radar with predictive wind shear detection capabilities

    NASA Technical Reports Server (NTRS)

    Kuntman, Daryal

    1991-01-01

    The status of Bendix research on Doppler weather radar with predictive wind shear detection capability is given in viewgraph form. Information is given on the RDR-4A, a fully coherent, solid state transmitter having Doppler turbulence capability. Frequency generation data, plans, modifications, system characteristics and certification requirements are covered.

  1. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1550 Ultrasonic pulsed doppler imaging...

  2. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1550 Ultrasonic pulsed doppler imaging...

  3. Tissue Doppler characterization of cardiac phenotype in mouse.

    PubMed

    Fayssoil, Abdallah

    2009-10-01

    Mice allow biologists to study various genes playing a role in cardiac function and pathophysiological situations. Echocardiography is a non-invasive tool for assessing cardiac phenotype. Because of load dependence of conventional parameters (left ventricular shortening fraction, left ventricular ejection fraction and mitral pulsed Doppler), we have to perform Doppler tissular velocity imaging and strain imaging for the characterization of cardiomyopathies mice models.

  4. Ionospheric observations made by a time-interleaved Doppler ionosonde

    NASA Astrophysics Data System (ADS)

    Lynn, Kenneth J. W.

    2008-10-01

    Mid-latitude HF observations of ionospheric Doppler velocity as a function of frequency are reported here as observed over a quiet 24-h period by a KEL IPS71 ionosonde operating at a 5-min sampling rate. The unique time-interleaving technique used in this ionosonde provided a Doppler resolution of 0.04 Hz over a Doppler range of ±2.5 Hz at each sounding frequency via FFT processing and is described here for the first time. The time-interleaving technique can be applied to other types of ionosonde as well as to other applications. The measurements described were made at a middle latitude site (Salisbury, South Australia). Doppler variations (<30 min) were ever present throughout the day and showed short-period TID characteristics. The day-time Doppler shift was found to closely follow the rate-of-change of foF2 as predicted by a simple parabolic layer model. The descending cusp in short-period TIDs is shown to mark an abrupt change with increasing frequency from negative towards positive Doppler shift with the greatest change in Doppler shift being observed below the cusp. The “smilergram” is introduced as observed in both F2 and Sporadic E. The characteristic curve in Doppler versus group height at a single frequency is described and related to changes in reflection symmetry, velocity and depth of moving ionospheric inhomogeneities.

  5. Imaging doppler velocimeter with downward heterodyning in the optical domain

    DOEpatents

    Reu, Phillip L; Hansche, Bruce D

    2013-05-21

    In a Doppler velocimeter, the incoming Doppler-shifted beams are heterodyned to reduce their frequencies into the bandwidth of a digital camera. This permits the digital camera to produce at every sampling interval a complete two-dimensional array of pixel values. This sequence of pixel value arrays provides a velocity image of the target.

  6. Investigations of atmospheric dynamics using a CW Doppler sounder array

    NASA Technical Reports Server (NTRS)

    Rao, G. L.

    1974-01-01

    A three-dimensional CW Doppler sounding system currently under operation at the NASA-Marshall Space Flight Center, Alabama is described. The properties of the neutral atmosphere are discussed along with the theory of Doppler sounding technique. Methods of data analyses used to investigate the dynamical phenomena at the ionospheric heights are presented and suggestions for future investigations provided.

  7. An elementary approach to the gravitational Doppler shift

    NASA Astrophysics Data System (ADS)

    Wörner, C. H.; Rojas, Roberto

    2017-01-01

    In college physics courses, treatment of the Doppler effect is usually done far from the first introduction to kinematics. This paper aims to apply a graphical treatment to describe the gravitational redshift, by considering the Doppler effect in two accelerated reference frames and exercising the equivalence principle. This approach seems appropriate to discuss with beginner students and could serve to enrich the didactic processes.

  8. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines...

  9. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines...

  10. Comparison of harmonic and conventional power Doppler ultrasonography for assessment of slow flow in hyperechoic tissue: experimental study using a Doppler phantom.

    PubMed

    Kim, A Y; Kim, T K; Kim, Y H; Han, J K; Choi, B I

    2000-02-01

    Despite the advantages of depicting slow flow in small vessels, conventional power Doppler ultrasound (US) has a basic limitation, specifically that artifactual power Doppler signals mimic blood flow, especially in hyperechoic tissue. The purpose of this study was to compare harmonic power Doppler US with power Doppler US using a Doppler phantom under various parameter settings, focusing on the assessment of slow flow in the hyperechoic tissue. While controlling the flow velocity (5 and 10 cm/s), pulse repetition frequency (500, 700, and 1,000 Hz), wall filter (low and medium), and Doppler gain (90%, 96%, and 100%), the authors performed both harmonic Doppler US and power Doppler US by using a Doppler phantom/flow control system. We measured and compared the relative intensities of the Doppler signals (0-250 scale) in both the vessels and hyperechoic tissue-mimicking materials with the two different imaging modalities. Power Doppler US with any combination of the four parameters evaluated depicted strong flow signals (mean, 213) that were superior to harmonic Doppler US (mean, 61). Relatively strong artifactual signals within the hyperechoic tissue-mimicking materials were noted on all power Doppler US studies (mean, 106) but nearly none on harmonic Doppler US (mean, 3). The contrast-to-noise ratio of harmonic Doppler US was significantly greater than that of power Doppler US. Harmonic Doppler US is more useful in assessing slow flow in hyperechoic tissue than power Doppler US because it produces fewer artifactual Doppler signals originating from stationary hyperechoic tissues, which can be misjudged as true signals on power Doppler US.

  11. Rotational Doppler effect in x-ray photoionization

    SciTech Connect

    Sun Yuping; Wang Chuankui; Gel'mukhanov, Faris

    2010-11-15

    The energy of the photoelectron experiences a red or blue Doppler shift when the molecule recedes from the detector or approaches him. This results in a broadening of the photoelectron line due to the translational thermal motion. However, the molecules also have rotational degrees of freedom and we show that the translational Doppler effect has its rotational counterpart. This rotational Doppler effect leads to an additional broadening of the spectral line of the same magnitude as the Doppler broadening caused by translational thermal motion. The rotational Doppler broadening as well as the rotational recoil broadening is sensitive to the molecular orbital from which the photoelectron is ejected. This broadening should be taken into account in analysis of x-ray photoemission spectra of super-high resolution and it can be directly observed using x-ray pump-probe spectroscopy.

  12. Spline function approximation for velocimeter Doppler frequency measurement

    NASA Technical Reports Server (NTRS)

    Savakis, Andreas E.; Stoughton, John W.; Kanetkar, Sharad V.

    1989-01-01

    A spline function approximation approach for measuring the Doppler spectral peak frequency in a laser Doppler velocimeter system is presented. The processor is designed for signal bursts with mean Doppler shift frequencies up to 100 MHz, input turbulence up to 20 percent, and photon counts as low as 300. The frequency-domain processor uses a bank of digital bandpass filters for the capture of the energy spectrum of each signal burst. The average values of the filter output energies, as a function of normalized frequency, are modeled as deterministic spline functions which are linearly weighted to evaluate the spectral peak location associated with the Doppler shift. The weighting coefficients are chosen to minimize the mean square error. Performance evaluation by simulation yields average errors in estimating mean Doppler frequencies within 0.5 percent for poor signal-to-noise conditions associated with a low photon count of 300 photons/burst.

  13. Ultrasound and colour Doppler in infantile subglottic haemangioma.

    PubMed

    Rossler, Leo; Rothoeft, T; Teig, N; Koerner-Rettberg, C; Deitmer, T; Rieger, C H L; Hamelmann, E

    2011-11-01

    Subglottic haemangioma causes progressive and life-threatening stridor, typically manifesting at age 2-3 months. Standard diagnosis is by laryngoscopy. Larynx sonography is rarely used but allows assessment of the presence and extension of a mass that impinges on the subglottic airway. The additional use of colour Doppler enables demonstration of the vascular nature of such masses. To compare US and endoscopic findings in infants with subglottic haemangioma and to evaluate accuracy of US and colour Doppler imaging in this diagnosis. We report eight infants with subglottic haemangioma seen in our institution over the last decade. They presented with laryngeal stridor and were all investigated with both US and endoscopy. Six infants underwent colour Doppler sonography. US and endoscopic findings showed excellent anatomical correlation in lateral subglottic haemangioma. Colour Doppler imaging was deemed helpful in four infants. Larynx sonography with complementary colour Doppler imaging was non-invasive and helpful in the diagnosis of subglottic haemangioma.

  14. One way Doppler extractor. Volume 1: Vernier technique

    NASA Technical Reports Server (NTRS)

    Blasco, R. W.; Klein, S.; Nossen, E. J.; Starner, E. R.; Yanosov, J. A.

    1974-01-01

    A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

  15. Doppler-cancelled response to VLF gravitational waves

    NASA Technical Reports Server (NTRS)

    Caporali, A.

    1981-01-01

    The interaction of long periodic gravitational waves with a three link microwave system known as the Doppler Cancelling System is discussed. This system, which was developed for a gravitational redshift experiment, uses one-way and two-way Doppler informatin to construct the beat signal of two reference oscillators moving with respect to each other. The geometric optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational wave space-time. The signature left on the Doppler-cancelled beat by burst and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler Cancelling System and that of a Doppler tracking system which employs two-way, round-trip radio waves. A three-fold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  16. Position finding using simple Doppler sensors

    NASA Astrophysics Data System (ADS)

    Schelkshorn, S.; Detlefsen, J.

    2007-06-01

    An increasing number of modern applications and services is based on the knowledge of the users actual position. Depending on the application a rough position estimate is sufficient, e. g. services in cellular networks that use the information about the users actual cell. Other applications, e. g. navigation systems use the GPS-System for accurate position finding. Beyond these outdoor applications a growing number of indoor applications requires position information. The previously mentioned methods for position finding (mobile cell, GPS) are not usable for these indoor applications. Within this paper we will present a system that relies on the simultaneous measurement of doppler signals at four different positions to obtain position and velocity of an unknown object. It is therefore suiteable for indoor usage, extendig already existing wireless infrastructure.

  17. Microscale Heat Conduction Models and Doppler Feedback

    SciTech Connect

    Hawari, Ayman I.; Ougouag, Abderrafi

    2015-01-22

    The objective of this project is to establish an approach for providing the fundamental input that is needed to estimate the magnitude and time-dependence of the Doppler feedback mechanism in Very High Temperature reactors. This mechanism is the foremost contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic (TRISO) coated particles. Therefore, its correct prediction is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat deposition, heat transfer and temperature rise must be correctly predicted. To achieve the above objective, this project will explore an approach that accounts for lattice effects as well as local temperature variations and the correct definition of temperature and related local effects.

  18. Doppler Global Velocimetry: The Next Generation?

    NASA Technical Reports Server (NTRS)

    Meyers, James F.

    1991-01-01

    A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. To assess the capability of this new technique, velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA Langley Basic Aerodynamics Research Tunnel. The operation of the system is described along with the techniques developed to process the output images. The results are then compared with similar measurements obtained using a three component laser velocimeter.

  19. Signal Processing Schemes for Doppler Global Velocimetry

    NASA Technical Reports Server (NTRS)

    Meyers, James F.; Lee, Joseph W.; Cavone, Angelo A.

    1991-01-01

    Two schemes for processing signals obtained from the Doppler global velocimeter are described. The analog approach is a simple, real time method for obtaining an RS-170 video signal containing the normalized intensity image. Pseudo colors are added using a monochromatic frame grabber producing a standard NTSC video signal that can be monitored and/or recorded. The digital approach is more complicated, but maintains the full resolution of the acquisition cameras with the capabilities to correct the signal image for pixel sensitivity variations and to remove of background light. Prototype circuits for each scheme are described and example results from the investigation of the vortical flow field above a 75-degree delta wing presented.

  20. Analytic radar micro-Doppler signatures classification

    NASA Astrophysics Data System (ADS)

    Oh, Beom-Seok; Gu, Zhaoning; Wang, Guan; Toh, Kar-Ann; Lin, Zhiping

    2017-06-01

    Due to its capability of capturing the kinematic properties of a target object, radar micro-Doppler signatures (m-DS) play an important role in radar target classification. This is particularly evident from the remarkable number of research papers published every year on m-DS for various applications. However, most of these works rely on the support vector machine (SVM) for target classification. It is well known that training an SVM is computationally expensive due to its nature of search to locate the supporting vectors. In this paper, the classifier learning problem is addressed by a total error rate (TER) minimization where an analytic solution is available. This largely reduces the search time in the learning phase. The analytically obtained TER solution is globally optimal with respect to the classification total error count rate. Moreover, our empirical results show that TER outperforms SVM in terms of classification accuracy and computational efficiency on a five-category radar classification problem.

  1. Cyclotron maser using the anomalous Doppler effect

    NASA Astrophysics Data System (ADS)

    Didenko, A. N.; Borisov, A. R.; Fomenko, G. P.; Shlapakovskii, A. S.; Shtein, Iu. G.

    1983-11-01

    The operation of an anomalous-Doppler-effect cyclotron-resonance maser using a waveguide partially filled with dielectric as the slow-wave system is reported. The device investigated is similar to that of Didenko et al. (1983) and comprises a 300-mm-long 50-mm-o.d. 30-mm-i.d. waveguide with fabric-laminate dielectric, located 150 mm from the cathode in a 500-mm-long region of uniform 0-20-kG magnetic field, and a coaxial magnetic-insulation gun producing a 13-mm-i.d. 25-mm-o.d. hollow electron beam. Radiation at 12 + or - 1 mm wavelength and optimum power 20 MW is observed using hot-carrier detectors, with a clear peak in the power-versus-magnetic-field curve at about 6.4 kG.

  2. Spacecraft Doppler tracking with a VLBI antenna

    NASA Astrophysics Data System (ADS)

    Comoretto, G.; Iess, L.; Bertotti, B.; Brenkle, J. P.; Horton, T.

    1990-02-01

    Preliminary results are reported from Doppler-shift measurements to the Voyager-2 spacecraft at a distance of 26 AU, obtained using the 32-m VLBI antenna at Medicina (Italy) during July and August 1988. The apparatus comprises the el-az antenna, an S-X-band receiver, a hydrogen maser to generate the reference signal, a Mark III VLBI terminal, and a digital tone extractor capable of isolating a tone of known frequency from a noisy signal and giving its phase and amplitude. A signal transmitted in S-band from the NASA Deep Space Network (DSN) station in Australia and retransmitted coherently in X-band by Voyager, was received 7 h 6 min later at Medicina and at the DSN station in Madrid. Sample data are presented graphically and shown to be of generally high quality; further in-depth analysis is under way.

  3. Spacecraft Doppler tracking with a VLBI antenna

    NASA Technical Reports Server (NTRS)

    Comoretto, G.; Iess, L.; Bertotti, B.; Brenkle, J. P.; Horton, T.

    1990-01-01

    Preliminary results are reported from Doppler-shift measurements to the Voyager-2 spacecraft at a distance of 26 AU, obtained using the 32-m VLBI antenna at Medicina (Italy) during July and August 1988. The apparatus comprises the el-az antenna, an S-X-band receiver, a hydrogen maser to generate the reference signal, a Mark III VLBI terminal, and a digital tone extractor capable of isolating a tone of known frequency from a noisy signal and giving its phase and amplitude. A signal transmitted in S-band from the NASA Deep Space Network (DSN) station in Australia and retransmitted coherently in X-band by Voyager, was received 7 h 6 min later at Medicina and at the DSN station in Madrid. Sample data are presented graphically and shown to be of generally high quality; further in-depth analysis is under way.

  4. Laser Doppler systems in atmospheric turbulence

    NASA Technical Reports Server (NTRS)

    Murty, S. S. R.

    1976-01-01

    The loss of heterodyne signal power for the Marshall Space Flight Center laser Doppler system due to the random changes in the atmospheric index of refraction is investigated. The current status in the physics of low energy laser propagation through turbulent atmosphere is presented. The analysis and approximate evaluation of the loss of the heterodyne signal power due to the atmospheric absorption, scattering, and turbulence are estimated for the conditions of the January 1973 flight tests. Theoretical and experimental signal to noise values are compared. Maximum and minimum values of the atmospheric attenuation over a two way path of 20 km range are calculated as a function of altitude using models of atmosphere, aerosol concentration, and turbulence.

  5. The generalized Doppler effect for surface waves

    NASA Astrophysics Data System (ADS)

    Michel, G.

    2016-11-01

    We investigate energy exchanges through scales occurring when a surface wave reflects on a harmonically oscillating wall. We first experimentally evidence the creation of Doppler-shifted waves and measure their height as a function of the oscillation amplitude. Then, we theoretically compute the amplitudes of these new waves in the gravity regime. Both results show that even without bulk non-linearities, oscillating paddles in a fluid container lead to a complex wave energy spectrum competing with the one predicted by wave turbulence. To exemplify this point, we characterize a simple one-dimensional model consisting of a linear wave equation in an oscillating cavity with distinct injection and dissipation mechanisms. It displays features usually associated with non-linearities, as self-similarity in a spectral domain (the so-called inertial range), appearance of energy at larger and/or lower scales than the forcing one and creation of shock waves.

  6. NEXRAD - An advanced Doppler weather radar system

    NASA Astrophysics Data System (ADS)

    Durham, A. F.

    The WSR-57 system, which was first placed into operation in 1957, forms the backbone of the current radar observation network of the National Weather Service. However, in connection with its age, it has become increasingly difficult and expensive to maintain this system. The present investigation is concerned with the replacement of the WSR-57 by a new system which incorporates important advances made in radar technology since the 1950s. The new system considered, called the Next Generation Weather Radar (NEXRAD) makes use of highly automated Doppler techniques to measure the radial velocity of air movement within the internal structure of a storm system. Attention is given to background regarding the NEXRAD system development, the four phases of the NEXRAD program, NEXRAD system capabilities, operational (display) products, and questions of siting.

  7. Laser Doppler vibrometry: new ENT applications

    NASA Astrophysics Data System (ADS)

    Stasche, Norbert; Baermann, M.; Kempe, C.; Hoermann, Karl; Foth, Hans-Jochen

    1996-12-01

    Common audiometry often does not really allow a reliable and objective differential diagnosis of hearing disorders such as otosclerosis, adhesive otitis, ossicular interruption or tinnitus, even though several methods might be used complementarily. In recent years, some experimental studies on middle ear mechanics established laser Doppler vibrometry (LDV) as a useful method allowing objective measurement of human tympanic membrane displacement. The present study on LDV investigated the clinical use of this new method under physiological conditions. LDV proved to be a fast, reproducible, non-invasive and very sensitive instrument to characterize ear-drum vibrations in various middle ear dysfunctions, except in tinnitus patients. For future applications, improved optical characteristics of the vibrometer might result in a better differential diagnosis of subjective and objective tinnitus, otoacoustic emissions or Morbus Meniere.

  8. The Christian Doppler Laboratory on Contextual Interfaces

    NASA Astrophysics Data System (ADS)

    Grill, Thomas; Reitberger, Wolfgang; Obrist, Marianna; Meschtscherjakov, Alexander; Tscheligi, Manfred

    Contextual interfaces gain more and more importance within the last years. Numerous research programs that address the term context have been established, each focusing on context from their own point of view. The Christian Doppler Laboratory on Contextual Interfaces has been founded with different goals in mind. The first goal is to elaborate on the definitions and foundations of the term context to achieve a common understanding on how to use context and the terms related to context. Further we elaborate on the relation between context and user experience to tackle the complexity of the interrelations between both areas. The second goal is to apply the findings of the basic context research with two different context laboratories, each addressing a different application area. This allows to build a robust research basis that is applied to application oriented research.

  9. Laser Doppler vibrometer employing active frequency feedback.

    PubMed

    Chijioke, Akobuije; Lawall, John

    2008-09-20

    We present a heterodyne Michelson interferometer for vibration measurement in which feedback is used to obviate the need to unwrap phase data. The Doppler shift of a vibrating target mirror is sensed interferometrically and compensated by means of a voltage-controlled oscillator driving an acousto-optic modulator. For frequencies within the servo bandwidth, the oscillator control voltage provides a direct measurement of the target velocity. Outside the servo bandwidth, phase-sensitive detection is used to evaluate high-frequency displacements. This approach is of great interest for the frequently-occurring situation where vibration amplitudes at low frequency exceed an optical wavelength, but knowledge of the vibration spectrum at high frequency is important as well.

  10. Hands-Free Transcranial Color Doppler Probe

    NASA Technical Reports Server (NTRS)

    Chin, Robert; Madala, Srihdar; Sattler, Graham

    2012-01-01

    Current transcranial color Doppler (TCD) transducer probes are bulky and difficult to move in tiny increments to search and optimize TCD signals. This invention provides miniature motions of a TCD transducer probe to optimize TCD signals. The mechanical probe uses spherical bearing in guiding and locating the tilting crystal face. The lateral motion of the crystal face as it tilts across the full range of motion was achieved by minimizing the distance between the pivot location and the crystal face. The smallest commonly available metal spherical bearing was used with an outer diameter of 12 mm, a 3-mm tall retaining ring, and 5-mm overall height. Small geared motors were used that would provide sufficient power in a very compact package. After confirming the validity of the basic positioning concept, optimization design loops were completed to yield the final design.

  11. Spacecraft Doppler tracking with a VLBI antenna

    NASA Technical Reports Server (NTRS)

    Comoretto, G.; Iess, L.; Bertotti, B.; Brenkle, J. P.; Horton, T.

    1990-01-01

    Preliminary results are reported from Doppler-shift measurements to the Voyager-2 spacecraft at a distance of 26 AU, obtained using the 32-m VLBI antenna at Medicina (Italy) during July and August 1988. The apparatus comprises the el-az antenna, an S-X-band receiver, a hydrogen maser to generate the reference signal, a Mark III VLBI terminal, and a digital tone extractor capable of isolating a tone of known frequency from a noisy signal and giving its phase and amplitude. A signal transmitted in S-band from the NASA Deep Space Network (DSN) station in Australia and retransmitted coherently in X-band by Voyager, was received 7 h 6 min later at Medicina and at the DSN station in Madrid. Sample data are presented graphically and shown to be of generally high quality; further in-depth analysis is under way.

  12. Widefield laser doppler velocimeter: development and theory.

    SciTech Connect

    Hansche, Bruce David; Reu, Phillip L.; Massad, Jordan Elias

    2007-03-01

    The widefield laser Doppler velocimeter is a new measurement technique that significantly expands the functionality of a traditional scanning system. This new technique allows full-field velocity measurements without scanning, a drawback of traditional measurement techniques. This is particularly important for tests in which the sample is destroyed or the motion of the sample is non-repetitive. The goal of creating ''velocity movies'' was accomplished during the research, and this report describes the current functionality and operation of the system. The mathematical underpinnings and system setup are thoroughly described. Two prototype experiments are then presented to show the practical use of the current system. Details of the corresponding hardware used to collect the data and the associated software to analyze the data are presented.

  13. Doppler cooling and trapping on forbidden transitions.

    PubMed

    Binnewies, T; Wilpers, G; Sterr, U; Riehle, F; Helmcke, J; Mehlstäubler, T E; Rasel, E M; Ertmer, W

    2001-09-17

    Ultracold atoms at temperatures close to the recoil limit have been achieved by extending Doppler cooling to forbidden transitions. A cloud of (40)Ca atoms has been cooled and trapped to a temperature as low as 6 microK by operating a magnetooptical trap on the spin-forbidden intercombination transition. Quenching the long-lived excited state with an additional laser enhanced the scattering rate by a factor of 15, while a high selectivity in velocity was preserved. With this method, more than 10% of precooled atoms from a standard magnetooptical trap have been transferred to the ultracold trap. Monte Carlo simulations of the cooling process are in good agreement with the experiments.

  14. Doppler interpretation of quasar red shifts.

    PubMed

    Zapolsky, H S

    1966-08-05

    The hypothesis that the quasistellar sources (quasars) are local objects moving with velocities close to the speed of light is examined. Provided there is no observational cutoff on apparent bolometric magnitude for the quasars, the transverse Doppler effect leads to the expectation of fewer blue shifts than red shifts for an isotropic distribution of velocities. Such a distribution also yields a function N(z), the number of objects with red shift less than z which is not inconsistent with the present data. On the basis of two extreme assumptions concerning the origin of such rapidly moving sources, we computed curves of red shift plotted against magnitude. In particular, the curve obtained on the assumption that the quasars originated from an explosion in or nearby our own galaxy is in as good agreement with the observations as the curve of cosmological red shift plotted against magnitude.

  15. [Use of laser Doppler flowmetry in dentistry].

    PubMed

    Roeykens, H; Nammour, S; De Moor, R

    2009-01-01

    An early determination of pulpal vitality is crucial with respect to a correct differential diagnosis of revascularisation or necrosis and its treatment. The use of sensibility tests (cold, heat, electrical pulp test) in combination with X-ray are commonly promoted. However these tests are arbitrary, based on sensations and therefore not always reliable. In such situation the registration of 'real' pulpal blood flow and hence pulp vitality will be more than an added value. The most studied and well documented method is laser Doppler flowmetry (LDF) as it is non invasive, direct and objective. In this article we describe blood flow, LDF and its characteristics, advantages and disadvantages of this method and the newest developments regarding LDF. Despite a low implementation of LDF in Belgium, this technique proved to belong indisputable to the basic assets of a dental clinic. A number of cases are described to demonstrate the efficacy and added value of LDF in assessing tooth vitality.

  16. DC coupled Doppler radar physiological monitor.

    PubMed

    Zhao, Xi; Song, Chenyan; Lubecke, Victor; Boric-Lubecke, Olga

    2011-01-01

    One of the challenges in Doppler radar systems for physiological monitoring is a large DC offset in baseband outputs. Typically, AC coupling is used to eliminate this DC offset. Since the physiological signals of interest include frequency content near DC, it is not desirable to simply use AC coupling on the radar outputs. While AC coupling effectively removes DC offset, it also introduces a large time delay and distortion. This paper presents the first DC coupled IQ demodulator printed circuit board (PCB) design and measurements. The DC coupling is achieved by using a mixer with high LO to RF port isolation, resulting in a very low radar DC offset on the order of mV. The DC coupled signals from the PCB radar system were successfully detected with significant LNA gain without saturation. Compared to the AC coupled results, the DC coupled results show great advantages of less signal distortion and more accurate rate estimation.

  17. Processing of the laser Doppler velocimeter signals

    NASA Technical Reports Server (NTRS)

    Meyers, J. F.; Feller, W. V.

    1973-01-01

    The laser Doppler velocimeter (LDV) is a probeless technique that provides a remote measurement of mean and fluctuating velocities. The measurement is actually obtained from small particles embedded in the flow which scatter light from an illuminating laser beam interference pattern. A portion of this scattered light is collected by a photomultiplier which yields an electronic signal whose frequency is directly proportional to the velocity of the small particles. The purpose of this paper is to describe and critically compare three techniques most used to process this electronic signal. These techniques are: (1) spectrum analyzer - a frequency scanning filter (frequency domain instrument), (2) wide-band frequency tracker - a frequency lock loop (frequency domain instrument), and (3) high-speed frequency counter - an interval timer (time domain instrument). The study determines the ability of each technique to process the LDV signal and yield velocity data to be used in determining the flow characteristics.

  18. Phase Doppler anemometry as an ejecta diagnostic

    NASA Astrophysics Data System (ADS)

    Bell, D. J.; Chapman, D. J.

    2017-01-01

    When a shock wave is incident on a free surface, micron sized pieces of the material can be ejected from that surface. Phase Doppler Anemometry (PDA) is being developed to simultaneously measure the sizes and velocities of the individual shock induced ejecta particles; providing an important insight into ejecta phenomena. The results from experiments performed on the 13 mm bore light gas gun at the Institute of Shock Physics, Imperial College London are presented. Specially grooved tin targets were shocked at pressures of up to 14 GPa, below the melt on release pressure, to generate ejecta particles. These experiments are the first time that PDA has been successfully fielded on dynamic ejecta experiments. The results and current state of the art of the technique are discussed along with the future improvements required to optimise performance and increase usability.

  19. Wind Field Measurements With Airborne Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Menzies, Robert T.

    1999-01-01

    In collaboration with lidar atmospheric remote sensing groups at NASA Marshall Space Flight Center and National Oceanic and Atmospheric Administration (NOAA) Environmental Technology Laboratory, we have developed and flown the Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) lidar on the NASA DC-8 research aircraft. The scientific motivations for this effort are: to obtain measurements of subgrid scale (i.e. 2-200 km) processes and features which may be used to improve parameterizations in global/regional-scale models; to improve understanding and predictive capabilities on the mesoscale; and to assess the performance of Earth-orbiting Doppler lidar for global tropospheric wind measurements. MACAWS is a scanning Doppler lidar using a pulsed transmitter and coherent detection; the use of the scanner allows 3-D wind fields to be produced from the data. The instrument can also be radiometrically calibrated and used to study aerosol, cloud, and surface scattering characteristics at the lidar wavelength in the thermal infrared. MACAWS was used to study surface winds off the California coast near Point Arena, with an example depicted in the figure below. The northerly flow here is due to the Pacific subtropical high. The coastal topography interacts with the northerly flow in the marine inversion layer, and when the flow passes a cape or point that juts into the winds, structures called "hydraulic expansion fans" are observed. These are marked by strong variation along the vertical and cross-shore directions. The plots below show three horizontal slices at different heights above sea level (ASL). Bottom plots are enlargements of the area marked by dotted boxes above. The terrain contours are in 200-m increments, with the white spots being above 600-m elevation. Additional information is contained in the original.

  20. Myocardial Tissue Doppler Velocity in Child Growth

    PubMed Central

    Choi, Sun-Ha; Kim, Nam Kyun; Jung, Jo Won; Choi, Jae Young

    2016-01-01

    Background In adults, tissue Doppler imaging (TDI) is a recommended component of routine echocardiography. However, TDI velocities are less accepted in pediatrics, due to their strong variability and age dependence in children. This study examines the distribution of myocardial tissue Doppler velocities in healthy children to assess the effect of age with cardiac growth on the various echocardiographic measurements. Methods Total 144 healthy children were enrolled in this study. They were recruited from the pediatric outpatient clinic for routine well-child visits. The statistical relationships between age and TDI values were analyzed. Also, the statistical relationships between body surface area (BSA) and TDI values, left ventricle end-diastolic dimension (LVEDD) and TDI values were analyzed. Also, we conducted multivariate analysis of cardiac growth parameters such as, age, BSA, LVEDD and TDI velocity data. Results All of the age, BSA, and LVEDD had positive correlations with deceleration time (DT), pressure half-time (PHT), peak early diastolic myocardial velocity, peak systolic myocardial velocity, and had negative correlations with peak late diastolic velocity (A) and the ratio of trans-mitral inflow velocity to early diastolic velocity of mitral annulus (E/E'). In the multivariate analysis, all of the age, BSA, and LVEDD had positive correlations with DT, PHT, and negative correlations with A and E/E'. Conclusion The cardiac growth parameters related alterations of E/E' may suggest that diastolic myocardial velocities are cardiac growth dependent, and diastolic function has positive correlation with cardiac growth in pediatric group. This cardiac growth related myocardial functional variation would be important for assessment of cardiac involvement either in healthy and sick child. PMID:27081443

  1. Laser Doppler flowmetry in endodontics: a review.

    PubMed

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  2. Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    PubMed

    Lorintiu, Oana; Liebgott, Herve; Friboulet, Denis

    2016-04-01

    In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal allowed reducing the number of Doppler emissions and yielded better results than traditional interpolation and at least equivalent or even better depending on the configuration than the study estimating the signal from sparse data sets given in Jensen, 2006. We propose here to improve over this study by using a novel framework for randomly interleaving Doppler and US emissions. The proposed method reconstructs the Doppler signal segment by segment using a block sparse Bayesian learning (BSBL) algorithm based CS reconstruction. The interest of using such framework in the context of duplex Doppler is linked to the unique ability of BSBL to exploit block-correlated signals and to recover non-sparse signals. The performance of the technique is evaluated from simulated data as well as experimental in vivo data and compared to the recent results in Richy , 2013.

  3. Clinical Applications of Doppler OCT and OCT Angiography

    NASA Astrophysics Data System (ADS)

    Tan, Ou; Jia, Yali; Wei, Eric; Huang, David

    Doppler optical coherence tomography (OCT) is a functional extension of OCT that allows for the visualization and measurement of blood flow [1, 2]. Phase-resolved Doppler OCT has become a standard algorithm for measuring Doppler shift with Fourier-domain (FD)-OCT because of its high velocity sensitivity [3]. In ophthalmology, several methods have been developed to measure in vivo retinal blood flow using this algorithm. Since Doppler OCT measures only the velocity component parallel to the OCT probe beam, additional information is needed to calculate absolute velocity and volumetric flow rate. One method is to employ two OCT beams with a fixed offset in incidence angles [4, 5]. However, this approach requires special hardware and is not compatible with commercial single-beam OCT systems. Another approach is to use special scan patterns to measure the Doppler angle (angle between the OCT beam and the blood vessel). Some groups used concentric scan patterns [6, 7], while other groups used raster scan patterns [8, 9]. Finally, Srinivasan et al. developed en face Doppler OCT for cerebral blood flow calculation, which obviated the need for Doppler angle estimation [10]. Bauman et al. adapted the method for total retinal blood flow (TRBF) calculation with ultrafast swept-source OCT [11]. In this chapter, we focus our attention on the double-circular scan pattern developed in our research group, which has been used in a number of clinical studies for preliminary demonstration of utility.

  4. Doppler sensitivity and its effect on transatlantic TWSTFT links

    NASA Astrophysics Data System (ADS)

    Zhang, Shengkang; Parker, Thomas; Zhang, Victor

    2017-02-01

    Some investigations have concluded that the diurnal pattern in the time comparison results of present two way satellite time and frequency transfer (TWSTFT) links may come mainly from Doppler dependent errors in the time of arrival (TOA) measurements made by the receivers of the TWSTFT modems. In this paper, several experiments were carried out to test if there is a Doppler dependent error in the ‘delay’ measurements of the receivers currently used. By simulating quantitative Doppler effects in the time transfer signal both on the carrier and the code, a type of Doppler sensitivity on the code was observed in the receivers, which has about  -0.49 ns offset in ‘delay’ measurement for a 1  ×  10-9 fractional Doppler shift. This sensitivity is basically the same for modems with different serial numbers from the same manufacture. We calculated this Doppler caused diurnal pattern in the time comparison results of the transatlantic TWSTFT link between NIST and PTB and found that it is very small and negligible, because the Doppler dependent error is almost identical in the NIST and PTB measurements and therefore it is nearly canceled in the TWSTFT difference. Commercial products are identified for technical completeness only, and no endorsement by NIST is implied.

  5. Pulsed Doppler echocardiographic analysis of mitral regurgitation after myocardial infarction.

    PubMed

    Loperfido, F; Biasucci, L M; Pennestri, F; Laurenzi, F; Gimigliano, F; Vigna, C; Rossi, E; Favuzzi, A; Santarelli, P; Manzoli, U

    1986-10-01

    In 72 patients with previous myocardial infarction (MI), mitral regurgitation (MR) was assessed by pulsed-wave Doppler echocardiography and compared with physical and 2-dimensional echocardiographic findings. MR was found by Doppler in 29 of 42 patients (62%) with anterior MI, 11 of 30 (37%) with inferior MI (p less than 0.01) and in none of 20 normal control subjects. MR was more frequent in patients who underwent Doppler study 3 months after MI than in those who underwent Doppler at discharge (anterior MI = 83% vs 50%, p less than 0.01; inferior MI = 47% vs 27%, p = not significant). Of 15 patients who underwent Doppler studies both times, 3 (all with anterior MI) had MR only on the second study. Of the patients with Doppler MR, 12 of 27 (44%) with a left ventricular (LV) ejection fraction (EF) greater than 30% and 1 of 13 (8%) with an EF of 30% or less (p less than 0.01) had an MR systolic murmur. Mitral prolapse or eversion and papillary muscle fibrosis were infrequent in MI patients, whether or not Doppler MR was present. The degree of Doppler MR correlated with EF (r = -0.61), LV systolic volume (r = 0.47), and systolic and diastolic mitral anulus circumference (r = 0.52 and 0.51, respectively). Doppler MR was present in 24 of 28 patients (86%) with an EF of 40% or less and in 16 of 44 (36%) with EF more than 40% (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Limits on Planetary Companions from Doppler Surveys of Nearby Stars

    NASA Astrophysics Data System (ADS)

    Howard, Andrew W.; Fulton, Benjamin J.

    2016-11-01

    Most of our knowledge of planets orbiting nearby stars comes from Doppler surveys. For spaced-based, high-contrast imaging missions, nearby stars with Doppler-discovered planets are attractive targets. The known orbits tell imaging missions where and when to observe, and the dynamically determined masses provide important constraints for the interpretation of planetary spectra. Quantifying the set of planet masses and orbits that could have been detected will enable more efficient planet discovery and characterization. We analyzed Doppler measurements from Lick and Keck Observatories by the California Planet Survey. We focused on stars that are likely targets for three space-based planet imaging mission concepts studied by NASA—WFIRST-AFTA, Exo-C, and Exo-S. The Doppler targets are primarily F8 and later main sequence stars, with observations spanning 1987-2014. We identified 76 stars with Doppler measurements from the prospective mission target lists. We developed an automated planet search and a methodology to estimate the pipeline completeness using injection and recovery tests. We applied this machinery to the Doppler data and computed planet detection limits for each star as a function of planet minimum mass and semimajor axis. For typical stars in the survey, we are sensitive to approximately Saturn-mass planets inside of 1 au, Jupiter-mass planets inside of ˜3 au, and our sensitivity declines out to ˜10 au. For the best Doppler targets, we are sensitive to Neptune-mass planets in 3 au orbits. Using an idealized model of Doppler survey completeness, we forecast the precision of future surveys of non-ideal Doppler targets that are likely targets of imaging missions. Based on observations obtained at the W. M. Keck Observatory, which is operated jointly by the University of California and the California Institute of Technology. Keck time has been granted by NASA, the University of California, and the University of Hawaii.

  7. Mitigating Doppler shift effect in HF multitone data modem

    NASA Astrophysics Data System (ADS)

    Sonlu, Yasar

    1989-09-01

    Digital communications over High Frequency (HF) radio channels are getting important in recent years. Current HF requirements are for data transmission at rates 2.4 kbps or more to accommodate computer data links and digital secure voice. HF modems which were produced to meet these speeds are, serial modems and parallel modems. On the other hand, the HF sky-wave communication medium, the ionosphere, has some propagation problems such as multipath and Doppler shift. The effect of Doppler shift in a parallel modem which employs Differential Quadrature Phase Shift Keying (DQPSK) modulation is considered and a correction method to mitigate the Doppler Shift effect is introduced.

  8. Automatic extraction of disease-specific features from Doppler images

    NASA Astrophysics Data System (ADS)

    Negahdar, Mohammadreza; Moradi, Mehdi; Parajuli, Nripesh; Syeda-Mahmood, Tanveer

    2017-03-01

    Flow Doppler imaging is widely used by clinicians to detect diseases of the valves. In particular, continuous wave (CW) Doppler mode scan is routinely done during echocardiography and shows Doppler signal traces over multiple heart cycles. Traditionally, echocardiographers have manually traced such velocity envelopes to extract measurements such as decay time and pressure gradient which are then matched to normal and abnormal values based on clinical guidelines. In this paper, we present a fully automatic approach to deriving these measurements for aortic stenosis retrospectively from echocardiography videos. Comparison of our method with measurements made by echocardiographers shows large agreement as well as identification of new cases missed by echocardiographers.

  9. Laboratory evaluation of microwave Doppler velocimeter for solid flow measurements

    NASA Astrophysics Data System (ADS)

    Wu, Z.; Wang, H. G.; Isa, M.; Liu, C. G.

    2014-04-01

    Pneumatic-conveyed solid flows are common in many industrial processes. The flow speed may be high and varying. The density of solids may also change with time. The mass flow rate is usually difficult to quantify for such multphase flows. On the other hand, microwave Doppler radar has been used as a device for velocity measurement or motion detection. It would be feasible to use such a device for solid flow measurements. In this paper, the principle of using microwave Doppler radar for such an application is investigated. Experimental results obtained using a microwave Doppler velocimeter for different types of solid flows in a laboratory environment are presented.

  10. Modular high accuracy tracker for dual channel laser Doppler velocimeter

    NASA Technical Reports Server (NTRS)

    Fridman, J. D.; Young, R. M.; Seavey, R. E.; Orloff, K. L.

    1976-01-01

    In the study described, a scanning dual-channel cross-beam laser Doppler velocimeter (developed for measuring simultaneously the two orthogonal components of flow velocity and turbulence intensity) was used to measure the instantaneous velocity characteristics of a model helicopter rotor and in a vortex wake survey experiment on a Boeing 747 aircraft model. Particular attention is given to a special purpose dual-loop frequency tracker developed to track and demodulate 10 microsecond wide pulse burst Doppler signals with a study cycle of 25% (or narrower signals at a higher duty cycle) generated by the laser Doppler velocimeter.

  11. Interferometric millimeter wave and THz wave doppler radar

    DOEpatents

    Liao, Shaolin; Gopalsami, Nachappa; Bakhtiari, Sasan; Raptis, Apostolos C.; Elmer, Thomas

    2015-08-11

    A mixerless high frequency interferometric Doppler radar system and methods has been invented, numerically validated and experimentally tested. A continuous wave source, phase modulator (e.g., a continuously oscillating reference mirror) and intensity detector are utilized. The intensity detector measures the intensity of the combined reflected Doppler signal and the modulated reference beam. Rigorous mathematics formulas have been developed to extract bot amplitude and phase from the measured intensity signal. Software in Matlab has been developed and used to extract such amplitude and phase information from the experimental data. Both amplitude and phase are calculated and the Doppler frequency signature of the object is determined.

  12. Laser Doppler anemometer signal processing for blood flow velocity measurements

    SciTech Connect

    Borozdova, M A; Fedosov, I V; Tuchin, V V

    2015-03-31

    A new method for analysing the signal in a laser Doppler anemometer based on the differential scheme is proposed, which provides the flow velocity measurement in strongly scattering liquids, particularly, blood. A laser Doppler anemometer intended for measuring the absolute blood flow velocity in animal and human near-surface arterioles and venules is developed. The laser Doppler anemometer signal structure is experimentally studied for measuring the flow velocity in optically inhomogeneous media, such as blood and suspensions of scattering particles. The results of measuring the whole and diluted blood flow velocity in channels with a rectangular cross section are presented. (laser applications and other topics in quantum electronics)

  13. Ultrasonic Doppler measurement of renal artery blood flow

    NASA Technical Reports Server (NTRS)

    Freund, W. R.; Beaver, W. L.; Meindl, J. D.

    1976-01-01

    Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.

  14. An audit of a hospital-based Doppler ultrasound quality control protocol using a commercial string Doppler phantom.

    PubMed

    Cournane, S; Fagan, A J; Browne, J E

    2014-05-01

    Results from a four-year audit of a Doppler quality assurance (QA) program using a commercially available Doppler string phantom are presented. The suitability of the phantom was firstly determined and modifications were made to improve the reliability and quality of the measurements. QA of Doppler ultrasound equipment is very important as data obtained from these systems is used in patient management. It was found that if the braided-silk filament of the Doppler phantom was exchanged with an O-ring rubber filament and the velocity range below 50 cm/s was avoided for Doppler quality control (QC) measurements, then the maximum velocity accuracy (MVA) error and intrinsic spectral broadening (ISB) results obtained using this device had a repeatability of 18 ± 3.3% and 19 ± 3.5%, respectively. A consistent overestimation of the MVA of between 12% and 56% was found for each of the tested ultrasound systems. Of more concern was the variation of the overestimation within each respective transducer category: MVA errors of the linear, curvilinear and phased array probes were in the range 12.3-20.8%, 32.3-53.8% and 27-40.7%, respectively. There is a dearth of QA data for Doppler ultrasound; it would be beneficial if a multicentre longitudinal study was carried out using the same Doppler ultrasound test object to evaluate sensitivity to deterioration in performance measurements.

  15. The Next Generation Airborne Polarimetric Doppler Radar

    NASA Astrophysics Data System (ADS)

    Vivekanandan, J.; Lee, Wen-Chau; Loew, Eric; Salazar, Jorge; Chandrasekar, V.

    2013-04-01

    NCAR's Electra Doppler radar (ELDORA) with a dual-beam slotted waveguide array using dual-transmitter, dual-beam, rapid scan and step-chirped waveform significantly improved the spatial scale to 300m (Hildebrand et al. 1996). However, ELDORA X-band radar's penetration into precipitation is limited by attenuation and is not designed to collect polarimetric measurements to remotely estimate microphysics. ELDORA has been placed on dormancy because its airborne platform (P3 587) was retired in January 2013. The US research community has strongly voiced the need to continue measurement capability similar to the ELDORA. A critical weather research area is quantitative precipitation estimation/forecasting (QPE/QPF). In recent years, hurricane intensity change involving eye-eyewall interactions has drawn research attention (Montgomery et al., 2006; Bell and Montgomery, 2006). In the case of convective precipitation, two issues, namely, (1) when and where convection will be initiated, and (2) determining the organization and structure of ensuing convection, are key for QPF. Therefore collocated measurements of 3-D winds and precipitation microphysics are required for achieving significant skills in QPF and QPE. Multiple radars in dual-Doppler configuration with polarization capability estimate dynamical and microphysical characteristics of clouds and precipitation are mostly available over land. However, storms over complex terrain, the ocean and in forest regions are not observable by ground-based radars (Bluestein and Wakimoto, 2003). NCAR/EOL is investigating potential configurations for the next generation airborne radar that is capable of retrieving dynamic and microphysical characteristics of clouds and precipitation. ELDORA's slotted waveguide array radar is not compatible for dual-polarization measurements. Therefore, the new design has to address both dual-polarization capability and platform requirements to replace the ELDORA system. NCAR maintains a C-130

  16. Ultraviolet-excimer laser-based incoherent Doppler lidar system

    NASA Technical Reports Server (NTRS)

    Mcdermid, I. Stuart; Laudenslager, James B.; Rees, David

    1985-01-01

    The topics covered include the following: principles of Doppler measurements, laser backscatter, eye safety, demonstration concepts, the wavelength-meter, the interferometer detector, return signal model, and comparison of incoherent and coherent lidars.

  17. Doing the Doppler. How to Drive This Concept Home.

    ERIC Educational Resources Information Center

    Koser, John F.

    1990-01-01

    An outdoor activity that demonstrates the Doppler effect is described. Class predictions are verified by actual involvement in collecting data. Presented is a method of analyzing data. Safety concerns are discussed. (KR)

  18. Doppler electron velocimetry : notes on creating a practical tool.

    SciTech Connect

    Reu, Phillip L.; Milster, Tom

    2008-11-01

    The Doppler electron velocimeter (DEV) has been shown to be theoretically possible. This report attempts to answer the next logical question: Is it a practical instrument? The answer hinges upon whether enough electrons are available to create a time-varying Doppler current to be measured by a detector with enough sensitivity and bandwidth. The answer to both of these questions is a qualified yes. A target Doppler frequency of 1 MHz was set as a minimum rate of interest. At this target a theoretical beam current signal-to-noise ratio of 25-to-1 is shown for existing electron holography equipment. A detector is also demonstrated with a bandwidth of 1-MHz at a current of 10 pA. Additionally, a Linnik-type interferometer that would increase the available beam current is shown that would offer a more flexible arrangement for Doppler electron measurements over the traditional biprism.

  19. Determining variability of ophthalmic arterial Doppler signals using Lyapunov exponents.

    PubMed

    Ubeyli, Elif Derya; Güler, Inan

    2005-06-01

    The new method presented in this study was directly based on the consideration that ophthalmic arterial Doppler signals are chaotic signals. This consideration was tested successfully using the nonlinear dynamics tools, like the computation of Lyapunov exponents. Multilayer perceptron neural network (MLPNN) architecture was formulated and used as a basis for determining variabilities such as stenosis, ocular Behcet disease, and uveitis disease in the physical state of ophthalmic arterial Doppler signals. The computed Lyapunov exponents of the ophthalmic arterial Doppler signals were used as inputs of the MLPNN. Receiver operating characteristic (ROC) curve was used to assess the performance of the detection process. The ophthalmic arterial Doppler signals were classified with the accuracy varying from 93.75% to 97.06%. The results confirmed that the proposed MLPNN trained with Levenberg-Marquardt algorithm has potential in detecting stenosis, Behcet disease and uveitis disease in ophthalmic arteries.

  20. Quantitative Measurement of the Doppler Shift at an Ultrasonic Frequency

    ERIC Educational Resources Information Center

    Nerbun, R. C.; Leskovec, R. A.

    1976-01-01

    Discussed is a Doppler shift laboratory experiment for an introductory college physics course. Ultrasonic transducers and a digital phase detector circuit "black box" are used to overcome room noise and "standing waves" and to produce an observable frequency shift. (SL)

  1. Coherent Doppler Lidar for Precision Navigation of Spacecrafts

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin; Pierrottet, Diego; Petway, Larry; Hines, Glenn; Lockhard, George; Barnes, Bruce

    2011-01-01

    A fiber-based coherent Doppler lidar, utilizing an FMCW technique, has been developed and its capabilities demonstrated through two successful helicopter flight test campaigns. This Doppler lidar is expected to play a critical role in future planetary exploration missions because of its ability in providing the necessary data for soft landing on the planetary bodies and for landing missions requiring precision navigation to the designated location on the ground. Compared with radars, the Doppler lidar can provide significantly higher precision velocity and altitude data at a much higher rate without concerns for measurement ambiguity or target clutter. Future work calls for testing the Doppler lidar onboard a rocket-powered free-flyer platform operating in a closed-loop with the vehicle s guidance, navigation, and control (GN&C) unit.

  2. On the sampling method of the JSZ-4 Doppler receiver.

    NASA Astrophysics Data System (ADS)

    Cha, D.-Y.; Huang, K.-Y.

    The authors discuss the properties of the JSZ-4 Doppler receiver and the problem of optimal record. It is shown that the original sampling method losses information. A procedure of improvement is proposed.

  3. Apparatus and method for noninvasive particle detection using doppler spectroscopy

    DOEpatents

    Sinha, Dipen N.

    2016-05-31

    An apparatus and method for noninvasively detecting the presence of solid particulate matter suspended in a fluid flowing through a pipe or an oil and gas wellbore are described. Fluid flowing through a conduit containing the particulate solids is exposed to a fixed frequency (>1 MHz) of ultrasonic vibrations from a transducer attached to the outside of the pipe. The returning Doppler frequency shifted signal derived from the scattering of sound from the moving solid particles is detected by an adjacent transducer. The transmitted signal and the Doppler signal are combined to provide sensitive particulate detection. The magnitude of the signal and the Doppler frequency shift are used to determine the particle size distribution and the velocity of the particles. Measurement of the phase shift between the applied frequency and the detected Doppler shifted may be used to determine the direction of motion of the particles.

  4. The Doppler Effect: A Consideration of Quasar Redshifts.

    ERIC Educational Resources Information Center

    Gordon, Kurtiss J.

    1980-01-01

    Provides information on the calculation of the redshift to blueshift ratio introduced by the transverse Doppler effect at relativistic speeds. Indicates that this shift should be mentioned in discussions of whether quasars are "local" rather than "cosmological" objects. (GS)

  5. [Doppler color ultrasonography in patients with erectile dysfunction].

    PubMed

    Migaleddu, V; Virgilio, G; Cucciari, P; Retanda, L; Carboni, C; Piras, P; Carboni, M; Canalis, G C

    2000-12-01

    The introduction of new oral therapy doesn't change the rule of color Doppler US in the screening modality of the diagnosis of vasculogenic impotence. The hemodynamic changes can be non invasively evaluated with color and energy Doppler US and with spectral analysis following injection of a vaso-active pharmacological agent. The new high sensitive US equipment allows an easy detection of the cavernous artery. Duplex Doppler can quantify the systolic-diastolic flow changes after the intra-cavernous vaso-active drugs injection. It is then possible to establish the diagnosis of arterial or venous vasculogenic impotence. The organic cause can also be excluded. The pick systolic velocity less than 0.30 m/sec is indicative of arterial origin. The absence of flow-reversal in the diastolic phase, 30 minutes after the injection, is significant for a venous type problem. Elicine arteries can be visualised and analysed using high sensitive color Doppler energy US equipment.

  6. Ambiguity Of Doppler Centroid In Synthetic-Aperture Radar

    NASA Technical Reports Server (NTRS)

    Chang, Chi-Yung; Curlander, John C.

    1991-01-01

    Paper discusses performances of two algorithms for resolution of ambiguity in estimated Doppler centroid frequency of echoes in synthetic-aperture radar. One based on range-cross-correlation technique, other based on multiple-pulse-repetition-frequency technique.

  7. Micro-Doppler processing for ultra-wideband radar data

    NASA Astrophysics Data System (ADS)

    Smith, Graeme E.; Ahmad, Fauzia; Amin, Moeness G.

    2012-06-01

    In this paper, we describe an operational pulse Doppler radar imaging system for indoor target localization and classification, and show how a target's micro-Doppler signature (μDS) can be processed when ultra-wideband (UWB) waveforms are employed. Unlike narrowband radars where time-frequency signal representations can be applied to reveal the target time-Doppler frequency signatures, the UWB system permits joint range-time-frequency representation (JRTFR). JRTFR outputs the data in a 3D domain representing range, frequency, and time, allowing both the μDS and high range resolution (HRR) signatures to be observed. We delineate the relationship between the μDS and the HRR signature, showing how they would form a complimentary joint feature for classification. We use real-data to demonstrate the effectiveness of the UWB pulse-Doppler radar, combined with nonstationary signal analyses, in gaining valuable insights into human positioning and motions.

  8. Extracting and analyzing micro-Doppler from ladar signatures

    NASA Astrophysics Data System (ADS)

    Tahmoush, Dave

    2015-05-01

    Ladar and other 3D imaging modalities have the capability of creating 3D micro-Doppler to analyze the micro-motions of human subjects. An additional capability to the recognition of micro-motion is the recognition of the moving part, such as the hand or arm. Combined with measured RCS values of the body, ladar imaging can be used to ground-truth the more sensitive radar micro-Doppler measurements and associate the moving part of the subject with the measured Doppler and RCS from the radar system. The 3D ladar signatures can also be used to classify activities and actions on their own, achieving an 86% accuracy using a micro-Doppler based classification strategy.

  9. Exploratory Meeting on Airborne Doppler Lidar Wind Velocity Measurements

    NASA Technical Reports Server (NTRS)

    Fichtel, G. H. (Editor); Kaufman, J. W. (Editor); Vaughan, W. W. (Editor)

    1980-01-01

    The scientific interests and applications of the Airborne Doppler Lidar Wind Velocity Measurement System to severe storms and local weather are discussed. The main areas include convective phenomena, local circulation, atmospheric boundary layer, atmospheric dispersion, and industrial aerodynamics.

  10. Doing the Doppler. How to Drive This Concept Home.

    ERIC Educational Resources Information Center

    Koser, John F.

    1990-01-01

    An outdoor activity that demonstrates the Doppler effect is described. Class predictions are verified by actual involvement in collecting data. Presented is a method of analyzing data. Safety concerns are discussed. (KR)

  11. The Doppler Effect: A Consideration of Quasar Redshifts.

    ERIC Educational Resources Information Center

    Gordon, Kurtiss J.

    1980-01-01

    Provides information on the calculation of the redshift to blueshift ratio introduced by the transverse Doppler effect at relativistic speeds. Indicates that this shift should be mentioned in discussions of whether quasars are "local" rather than "cosmological" objects. (GS)

  12. Three-dimensional echocardiography of colour Doppler flow.

    PubMed

    Zhou, Zhi-Wen; Xu, Ya-Wei; Ashraf, Muhammad; Sahn, David J

    2010-05-01

    Three-dimensional echocardiography of colour Doppler flow developed quickly with the advent of three-dimensional echocardiography. An increasing amount of research has shown that three-dimensional echocardiography of colour Doppler flow is feasible and facilitates measurement of stroke volume and cardiac output, and assessment of heart valve and congenital heart diseases. Although the technique still has some drawbacks that hamper its widespread use, as the technology continues to improve, three-dimensional echocardiography of colour Doppler flow has the potential to serve as a powerful noninvasive clinical tool, aiding physicians in the serial assessment of heart disease and response to intervention. We review the developmental history and the most recent clinical information related to three-dimensional echocardiography of colour Doppler flow. 2010 Elsevier Masson SAS. All rights reserved.

  13. Millimeter-wave micro-Doppler measurements of small UAVs

    NASA Astrophysics Data System (ADS)

    Rahman, Samiur; Robertson, Duncan A.

    2017-05-01

    This paper discusses the micro-Doppler signatures of small UAVs obtained from a millimeter-wave radar system. At first, simulation results are shown to demonstrate the theoretical concept. It is illustrated that whilst the propeller rotation rate of the small UAVs is quite high, millimeter-wave radar systems are capable of capturing the full micro-Doppler spread. Measurements of small UAVs have been performed with both CW and FMCW radars operating at 94 GHz. The CW radar was used for obtaining micro-Doppler signatures of individual propellers. The field test data of a flying small UAV was collected with the FMCW radar and was processed to extract micro-Doppler signatures. The high fidelity results clearly reveal features such as blade flashes and propeller rotation modulation lines which can be used to classify targets. This work confirms that millimeter-wave radar is suitable for the detection and classification of small UAVs at usefully long ranges.

  14. Laser Doppler technology applied to atmospheric environmental operating problems

    NASA Technical Reports Server (NTRS)

    Weaver, E. A.; Bilbro, J. W.; Dunkin, J. A.; Jeffreys, H. B.

    1976-01-01

    Carbon dioxide laser Doppler ground wind data were very favorably compared with data from standard anemometers. As a result of these measurements, two breadboard systems were developed for taking research data: a continuous wave velocimeter and a pulsed Doppler system. The scanning continuous wave laser Doppler velocimeter developed for detecting, tracking and measuring aircraft wake vortices was successfully tested at an airport where it located vortices to an accuracy of 3 meters at a range of 150 meters. The airborne pulsed laser Doppler system was developed to detect and measure clear air turbulence (CAT). This system was tested aboard an aircraft, but jet stream CAT was not encountered. However, low altitude turbulence in cumulus clouds near a mountain range was detected by the system and encountered by the aircraft at the predicted time.

  15. Quantitative Measurement of the Doppler Shift at an Ultrasonic Frequency

    ERIC Educational Resources Information Center

    Nerbun, R. C.; Leskovec, R. A.

    1976-01-01

    Discussed is a Doppler shift laboratory experiment for an introductory college physics course. Ultrasonic transducers and a digital phase detector circuit "black box" are used to overcome room noise and "standing waves" and to produce an observable frequency shift. (SL)

  16. Aliasing-tolerant color Doppler quantification of regurgitant jets.

    PubMed

    Stewart, S F

    1998-07-01

    Conservation of momentum transfer in regurgitant cardiac jets can be used to calculate the flow rate from color Doppler velocities. In this study, turbulent jets were simulated by finite elements; pseudocolor Doppler images were interpolated from the computations, with aliasing introduced artificially. Jets were also imaged by color Doppler in an in vitro flow system. To suppress aliasing errors, jet velocities were fitted iteratively to a fluid mechanical model constrained to match the orifice velocity (measured without aliasing by continuous-wave Doppler). At each iteration, the model was used to detect aliased velocities, which were excluded during the next iteration. Iteration continued until the flow rate calculated by the model and number of calculated nonaliased pixels were unchanged. The good correlations between measured and calculated flow rates in the experimental (R2 = 0.933) and computational studies (R2 = 0.990) suggest that this may be a clinically useful approach even in aliased images. Published by Elsevier Science Inc.

  17. Monitoring and Analysis of Respiratory Patterns Using Microwave Doppler Radar

    PubMed Central

    Pathirana, Pubudu N.; Steinfort, Christopher Louis; Caelli, Terry

    2014-01-01

    Noncontact detection characteristic of Doppler radar provides an unobtrusive means of respiration detection and monitoring. This avoids additional preparations, such as physical sensor attachment or special clothing, which can be useful for certain healthcare applications. Furthermore, robustness of Doppler radar against environmental factors, such as light, ambient temperature, interference from other signals occupying the same bandwidth, fading effects, reduce environmental constraints and strengthens the possibility of employing Doppler radar in long-term respiration detection, and monitoring applications such as sleep studies. This paper presents an evaluation in the of use of microwave Doppler radar for capturing different dynamics of breathing patterns in addition to the respiration rate. Although finding the respiration rate is essential, identifying abnormal breathing patterns in real-time could be used to gain further insights into respiratory disorders and refine diagnostic procedures. Several known breathing disorders were professionally role played and captured in a real-time laboratory environment using a noncontact Doppler radar to evaluate the feasibility of this noncontact form of measurement in capturing breathing patterns under different conditions associated with certain breathing disorders. In addition to that, inhalation and exhalation flow patterns under different breathing scenarios were investigated to further support the feasibility of Doppler radar to accurately estimate the tidal volume. The results obtained for both experiments were compared with the gold standard measurement schemes, such as respiration belt and spirometry readings, yielding significant correlations with the Doppler radar-based information. In summary, Doppler radar is highlighted as an alternative approach not only for determining respiration rates, but also for identifying breathing patterns and tidal volumes as a preferred nonwearable alternative to the conventional

  18. Software For Clear-Air Doppler-Radar Display

    NASA Technical Reports Server (NTRS)

    Johnston, Bruce W.

    1990-01-01

    System of software developed to present plan-position-indicator scans of clear-air Doppler radar station on color graphical cathode-ray-tube display. Designed to incorporate latest accepted standards for equipment, computer programs, and meteorological data bases. Includes use of Ada programming language, of "Graphical-Kernel-System-like" graphics interface, and of Common Doppler Radar Exchange Format. Features include portability and maintainability. Use of Ada software packages produced number of software modules reused on other related projects.

  19. Convolution of a Doppler line by a Gaussian instrument function

    NASA Technical Reports Server (NTRS)

    Fridovich, B.; Devi, V. M.; Das, P. P.

    1980-01-01

    A simple and direct method is obtained for assessing the distortion of a Doppler line by a Gaussian instrument function. It is suggested that a close approximation to the width of a Gaussian instrument function, or an almost Gaussian function, may be obtained by measuring a line with a Doppler absorption coefficient. The method is applicable to diode laser measurements, and may be used whenever a Gaussian instrument function is a reasonable approximation to real conditions

  20. Power Doppler evaluation of revascularization in childhood moyamoya.

    PubMed

    Perren, F; Meairs, S; Schmiedek, P; Hennerici, M; Horn, P

    2005-02-08

    Moyamoya disease is generally recognized in young children. One potential treatment is direct extra-intracranial bypass combined with indirect revascularization using encephalo-myo-synangiosis. Standard follow-up to assess neoangiogenesis includes repeat cerebral angiography, which is invasive. The authors studied whether noninvasive power Doppler imaging could evaluate the patency of the bypass and the degree of indirect revascularization. They found that transcranial power Doppler imaging is a valid noninvasive alternative to cerebral angiography.

  1. Using doppler radar images to estimate aircraft navigational heading error

    DOEpatents

    Doerry, Armin W [Albuquerque, NM; Jordan, Jay D [Albuquerque, NM; Kim, Theodore J [Albuquerque, NM

    2012-07-03

    A yaw angle error of a motion measurement system carried on an aircraft for navigation is estimated from Doppler radar images captured using the aircraft. At least two radar pulses aimed at respectively different physical locations in a targeted area are transmitted from a radar antenna carried on the aircraft. At least two Doppler radar images that respectively correspond to the at least two transmitted radar pulses are produced. These images are used to produce an estimate of the yaw angle error.

  2. Atmospheric aerosol and Doppler lidar studies

    NASA Technical Reports Server (NTRS)

    Rothermel, Jeff; Bowdle, D. A.; Srivastava, V.; Jarzembski, M.; Cutten, D.; Mccaul, E. W., Jr.

    1991-01-01

    Experimental and theoretical studies were performed of atmospheric aerosol backscatter and atmospheric dynamics with Doppler lidar as a primary tool. Activities include field and laboratory measurement and analysis efforts. The primary focus of activities related to understanding aerosol backscatter is the GLObal Backscatter Experiment (GLOBE) program. GLOBE is a multi-element effort designed toward developing a global aerosol model to describe tropospheric clean background backscatter conditions that Laser Atmospheric Wind Sounder (LAWS) is likely to encounter. Two survey missions were designed and flown in the NASA DC-8 in November 1989 and May to June 1990 over the remote Pacific Ocean, a region where backscatter values are low and where LAWS wind measurements could make a major contribution. The instrument complement consisted of pulsed and continuous-wave (CW) CO2 gas and solid state lidars measuring aerosol backscatter, optical particle counters measuring aerosol concentration, size distribution, and chemical composition, a filter/impactor system collecting aerosol samples for subsequent analysis, and integrating nephelometers measuring visible scattering coefficients. The GLOBE instrument package and survey missions were carefully planned to achieve complementary measurements under clean background backscatter conditions.

  3. Doppler-resolved kinetics of saturation recovery

    SciTech Connect

    Forthomme, Damien; Hause, Michael L.; Yu, Hua -Gen; Dagdigian, Paul J.; Sears, Trevor J.; Hall, Gregory E.

    2015-04-08

    Frequency modulated laser transient absorption has been used to monitor the ground state rotational energy transfer rates of CN radicals in a double-resonance, depletion recovery experiment. When a pulsed laser is used to burn a hole in the equilibrium ground state population of one rotational state without velocity selection, the population recovery rate is found to depend strongly on the Doppler detuning of a narrow-band probe laser. Similar effects should be apparent for any relaxation rate process that competes effectively with velocity randomization. Alternative methods of extracting thermal rate constants in the presence of these non-thermal conditions are evaluated. Total recovery rate constants, analogous to total removal rate constants in an experiment preparing a single initial rotational level, are in good agreement with quantum scattering calculations, but are slower than previously reported experiments and show qualitatively different rotational state dependence between Ar and He collision partners. As a result, quasi-classical trajectory studies confirm that the differing rotational state dependence is primarily a kinematic effect.

  4. Recent applications of acoustic Doppler current profilers

    USGS Publications Warehouse

    Oberg, K.A.; Mueller, David S.

    1994-01-01

    A Broadband acoustic Doppler current profiler (BB-ADCP) is a new instrument being used by the U.S. Geological Survey (USGS) to measure stream discharge and velocities, and bathymetry. During the 1993 Mississippi River flood, more than 160 high-flow BB-ADCP measurements were made by the USGS at eight locations between Quincy and Cairo, Ill., from July 19 to August 20, 1993. A maximum discharge of 31,400 m3/s was measured at St. Louis, Mo., on August 2, 1993. A BB-ADCP also has been used to measure leakage through three control structures near Chicago, Ill. These measurements are unusual in that the average velocity for the measured section was as low as 0.03 m/s. BB-ADCP's are also used in support of studies of scour at bridges. During the recent Mississippi River flood, BB-ADCP's were used to measure water velocities and bathymetry upstream from, next to, and downstream from bridge piers at several bridges over the Mississippi River. Bathymetry data were collected by merging location data from Global Positioning System (GPS) receivers, laser tracking systems, and depths measured by the BB-ADCP. These techniques for collecting bathymetry data were used for documenting the channel formation downstream from the Miller City levee break and scour near two bridges on the Mississippi River.

  5. Doppler radar detection of vortex hazard indicators

    NASA Technical Reports Server (NTRS)

    Nespor, Jerald D.; Hudson, B.; Stegall, R. L.; Freedman, Jerome E.

    1994-01-01

    Wake vortex experiments were conducted at White Sands Missile Range, NM using the AN/MPS-39 Multiple Object Tracking Radar (MOTR). The purpose of these experiments was twofold. The first objective was to verify that radar returns from wake vortex are observed for some time after the passage of an aircraft. The second objective was to verify that other vortex hazard indicators such as ambient wind speed and direction could also be detected. The present study addresses the Doppler characteristics of wake vortex and clear air returns based upon measurements employing MOTR, a very sensitive C-Band phased array radar. In this regard, the experiment was conducted so that the spectral characteristics could be determined on a dwell to-dwell basis. Results are presented from measurements of the backscattered power (equivalent structure constant), radial velocity and spectral width when the aircraft flies transverse and axial to the radar beam. The statistics of the backscattered power and spectral width for each case are given. In addition, the scan strategy, experimental test procedure and radar parameters are presented.

  6. Doppler lidar signal and turbulence study

    NASA Technical Reports Server (NTRS)

    Frost, W.; Huang, K. H.

    1983-01-01

    Wind fields were measured with the ground-based NASA/MSFC lidar are compared with the in situ NASA RB-57 aircraft measurements. The mean wind fields, the turbulence intensities, and the turbulence spectra determined from measurements by both systems are in very good agreement. Turbulence intensities and spectra were calculated from the fluctuations with time in the radial wind speed component. The second moment or Doppler frequency spectral width of the lidar measurements was also compared with turbulence intensities measured by the aircraft. These second moments could only be resolved at the very low altitudes (in three range bins). Turbulence intensities estimated from the spectral width data were an order of magnitude higher than those measured by the aircraft. An interesting boundary layer evolved during the progress of the experiment. The breakup of a stable boundary layer resulted in winds blowing in one direction above 600 m msl and in the opposite direction below that level. Both the aircraft and the lidar systems clearly identified this unusual boundary layer flow and showed the identical trends.

  7. Doppler effect induced spin relaxation boom

    PubMed Central

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-01-01

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures. PMID:26996253

  8. Doppler Tomography of A0620-00

    NASA Astrophysics Data System (ADS)

    Neilsen, Joseph; Steeghs, D.; Vrtilek, S. D.

    2007-05-01

    We present the results of spectroscopic observations of the quiescent black hole binary A0620-00 with LDSS3 on the Clay telescope at Las Campanas Observatory. We measure absorption-line radial velocities of the secondary and find K2=434.6±0.5 km/s; this is the most precise absorption-line radial velocity measurement for the system to date. By fitting the rotational broadening of the secondary, we measure the mass ratio q=0.060±0.04 these results, combined with the orbital period, imply a minimum mass for the compact object of 3.09±0.04 M⊙. Although X-ray quiescence implies little accretion activity, we find that the disk contributes ≥50% of the light in B and V, and is subject to significant flickering. The variability of the disk makes ellipsoidal constraints on the inclination nearly impossible. Doppler maps in Hα and Hβ show strong disk emission and a bright spot displaced from the gas stream; lower S/N lines show significant bright spot emission, consistent with Marsh et al. (1994). With high S/N, we pursue modulation tomography of Hα and find that the bright spot is strongly modulated at the orbital period. This research was funded by NSF grant 16640156, the Harvard University Graduate School of Arts and Sciences, and a Smithsonian Astrophysical Observatory Clay Fellowship.

  9. Zeeman Doppler Maps: Always Unique, Never Spurious?

    NASA Astrophysics Data System (ADS)

    Stift, Martin J.; Leone, Francesco

    2017-01-01

    Numerical models of atomic diffusion in magnetic atmospheres of ApBp stars predict abundance structures that differ from the empirical maps derived with (Zeeman) Doppler mapping (ZDM). An in-depth analysis of this apparent disagreement investigates the detectability by means of ZDM of a variety of abundance structures, including (warped) rings predicted by theory, but also complex spot-like structures. Even when spectra of high signal-to-noise ratio are available, it can prove difficult or altogether impossible to correctly recover shapes, positions, and abundances of a mere handful of spots, notwithstanding the use of all four Stokes parameters and an exactly known field geometry; the recovery of (warped) rings can be equally challenging. Inversions of complex abundance maps that are based on just one or two spectral lines usually permit multiple solutions. It turns out that it can by no means be guaranteed that any of the regularization functions in general use for ZDM (maximum entropy or Tikhonov) will lead to a true abundance map instead of some spurious one. Attention is drawn to the need for a study that would elucidate the relation between the stratified, field-dependent abundance structures predicted by diffusion theory on the one hand, and empirical maps obtained by means of “canonical” ZDM, i.e., with mean atmospheres and unstratified abundances, on the other hand. Finally, we point out difficulties arising from the three-dimensional nature of the atomic diffusion process in magnetic ApBp star atmospheres.

  10. Signature stability in laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Iverson, Thomas Z.; Watson, Edward A.

    2017-05-01

    Speckle can complicate signal acquisition in coherent laser systems such as Laser Doppler Vibrometry (LDV). Variations in the speckle pattern at the reliever due to fluctuations in the system such as beam pointing can lead to impulsive events in the signature. The beam size at the object has a direct influence on the size of the speckle at the receiving aperture. Increasing the beam spot size reduces the average speckle size, but also decreases the strength of the signal coupled with the local oscillator in the LDV. In this paper, we derive the relationship between scattering spot size at the object and average speckle size at the receiver. Theory is presented on how increasing the beam diameter at the object can reduce the fluctuations of the heterodyned signal coupled with the Local Oscillator (LO). The Antenna theorem is presented to show the tradeoff between angular field of view and capture area. We show experimental results on the effects of speckle size and decreasing signal strength have on the stability of an LDV signature. We use a kurtosis metric previously reported in the literature to assess the stability and quality of the return signature.

  11. Doppler-Resolved Kinetics of Saturation Recovery.

    PubMed

    Forthomme, Damien; Hause, Michael L; Yu, Hua-Gen; Dagdigian, Paul J; Sears, Trevor J; Hall, Gregory E

    2015-07-16

    Frequency-modulated laser transient absorption has been used to monitor the ground-state rotational energy-transfer rates of CN radicals in a double-resonance, depletion recovery experiment. When a pulsed laser is used to burn a hole in the equilibrium ground-state population of one rotational state without velocity selection, the population recovery rate is found to depend strongly on the Doppler detuning of a narrow-band probe laser. Similar effects should be apparent for any relaxation rate process that competes effectively with velocity randomization. Alternative methods of extracting thermal rate constants in the presence of these non-thermal conditions are evaluated. Total recovery rate constants, analogous to total removal rate constants in an experiment preparing a single initial rotational level, are in good agreement with quantum scattering calculations, but are slower than previously reported experiments and show qualitatively different rotational state dependence between Ar and He collision partners. Quasi-classical trajectory studies confirm that the differing rotational state dependence is primarily a kinematic effect.

  12. Doppler effect induced spin relaxation boom

    NASA Astrophysics Data System (ADS)

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-03-01

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures.

  13. Doppler effect induced spin relaxation boom.

    PubMed

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-03-21

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures.

  14. Doppler-resolved kinetics of saturation recovery

    DOE PAGES

    Forthomme, Damien; Hause, Michael L.; Yu, Hua -Gen; ...

    2015-04-08

    Frequency modulated laser transient absorption has been used to monitor the ground state rotational energy transfer rates of CN radicals in a double-resonance, depletion recovery experiment. When a pulsed laser is used to burn a hole in the equilibrium ground state population of one rotational state without velocity selection, the population recovery rate is found to depend strongly on the Doppler detuning of a narrow-band probe laser. Similar effects should be apparent for any relaxation rate process that competes effectively with velocity randomization. Alternative methods of extracting thermal rate constants in the presence of these non-thermal conditions are evaluated. Totalmore » recovery rate constants, analogous to total removal rate constants in an experiment preparing a single initial rotational level, are in good agreement with quantum scattering calculations, but are slower than previously reported experiments and show qualitatively different rotational state dependence between Ar and He collision partners. As a result, quasi-classical trajectory studies confirm that the differing rotational state dependence is primarily a kinematic effect.« less

  15. Muscle activity characterization by laser Doppler Myography

    NASA Astrophysics Data System (ADS)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  16. Smoke-Column Observations from Two Forest Fires Using Doppler Lidar and Doppler Radar.

    NASA Astrophysics Data System (ADS)

    Banta, R. M.; Olivier, L. D.; Holloway, E. T.; Kropfli, R. A.; Bartram, B. W.; Cupp, R. E.; Post, M. J.

    1992-11-01

    To demonstrate the usefulness of active remote-sensing systems in observing forest fire plume behavior, we studied two fires, one using a 3.2-cm-wavelength Doppler radar, and one more extensively, using Doppler lidar. Both instruments observed the kinematics of the convection column, including the presence of two different types of rotation in the columns, and monitored the behavior of the smoke plume.The first fire, a forest fire that burned out of control, was observed by the Doppler radar during late-morning and afternoon hours. Strong horizontal ambient winds produced a bent-over convection column, which the radar observed to have strong horizontal flow at its edges and weaker flow along the centerline of the plume. This velocity pattern implies that the column consisted of a pair of counterrotating horizontal vortices (rolls), with rising motion along the centerline and sinking along the edges. The radar tracked the smoke plume for over 30 km. It also provided circular depolarization ratio measurements, which gave information that the scattering particles were mostly flat or needle shaped as viewed by the radar, perhaps pine needles or possibly flat ash platelets being viewed edge on.The second fire, observed over a 5-h period by Doppler lidar, was a prescribed forest fire ignited in the afternoon. During the first hour of the fire the lidar observed many kinematic quantities of the convection column, including flow convergence and anticyclonic whole-column, rotation of the nearly vertical column, with a vorticity of approximately 102 s1 and an estimated peak vertical velocity w of 1 5 m s1. After the first hour ambient meteorological conditions changed, the whole-column rotation ceased, and the convection column and smoke plume bent over toward the lidar in stronger horizontal flow. At two times during this later stage, w was estimated to be 24 and 10 m s1. Lidar observations show that the smoke plume of this second fire initially went straight up in the

  17. Doppler velocity measurements from large and small arteries of mice

    PubMed Central

    Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.

    2011-01-01

    With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013

  18. Doppler Monitoring of the WASP-47 Multiplanet System

    NASA Astrophysics Data System (ADS)

    Dai, Fei; Winn, Joshua N.; Arriagada, Pamela; Butler, R. Paul; Crane, Jeffrey D.; Johnson, John Asher; Shectman, Stephen A.; Teske, Johanna K.; Thompson, Ian B.; Vanderburg, Andrew; Wittenmyer, Robert A.

    2015-11-01

    We present precise Doppler observations of WASP-47, a transiting planetary system featuring a hot Jupiter with both inner and outer planetary companions. This system has an unusual architecture and also provides a rare opportunity to measure planet masses in two different ways: the Doppler method, and the analysis of transit-timing variations (TTV). Based on the new Doppler data, obtained with the Planet Finder Spectrograph on the Magellan/Clay 6.5 m telescope, the mass of the hot Jupiter is 370+/- 29 {M}\\oplus . This is consistent with the previous Doppler determination as well as the TTV determination. For the inner planet WASP-47e, the Doppler data lead to a mass of 12.2+/- 3.7 {M}\\oplus , in agreement with the TTV-based upper limit of <22 M⊕ (95% confidence). For the outer planet WASP-47d, the Doppler mass constraint of 10.4+/- 8.4 {M}\\oplus is consistent with the TTV-based measurement of {15.2}-7.6+6.7 {M}\\oplus . This paper includes data gathered with the 6.5 m Magellan Telescopes located at Las Campanas Observatory, Chile.

  19. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking.

    PubMed

    Armstrong, J W

    2006-01-01

    This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (∼millihertz) gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity 2Δv/c = Δν/ν0, where Δν is the Doppler shift and ν0 is the radio link carrier frequency. A gravitational wave having strain amplitude h incident on the earth-spacecraft system causes perturbations of order h in the time series of Δν/ν0. Unlike other detectors, the ∼ 1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series), some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  20. Radar/sonar signal design for bounded Doppler shifts

    NASA Astrophysics Data System (ADS)

    Altes, R. A.

    1982-07-01

    In many detection and estimation problems, Doppler frequency shifts are bounded. For clutter or multipath that is uniformly distributed in range and symmetrically distributed in Doppler shift relative to the signal, detectability of a point target or a communication signal is improved by minimizing the weighted volume of the magnitude-squared autoambiguity function. When clutter Doppler shifts are bounded, this volume is in a strip containing the range axis on the range-Doppler plane. For scattering function estimation, e.g., for weather radar, Doppler flow meters, and distributed target classifiers, it is again relevant to minimize ambiguity volume in a strip. Strip volume is minimized by using a pulse train, but such a signal has unacceptably large range sidelobe for most applications. Other waveforms that have relatively small sidelobe level within a strip on the range-Doppler plane, as well as small ambiguity volume in the strip, are obtained. The waveforms are composed of pulse pairs that are phase modulated with Golay complementary codes.

  1. Analysis of airborne Doppler lidar, Doppler radar and tall tower measurements of atmospheric flows in quiescent and stormy weather

    NASA Technical Reports Server (NTRS)

    Bluestein, H. B.; Doviak, R. J.; Eilts, M. D.; Mccaul, E. W.; Rabin, R.; Sundara-Rajan, A.; Zrnic, D. S.

    1986-01-01

    The first experiment to combine airborne Doppler Lidar and ground-based dual Doppler Radar measurements of wind to detail the lower tropospheric flows in quiescent and stormy weather was conducted in central Oklahoma during four days in June-July 1981. Data from these unique remote sensing instruments, coupled with data from conventional in-situ facilities, i.e., 500-m meteorological tower, rawinsonde, and surface based sensors, were analyzed to enhance understanding of wind, waves and turbulence. The purposes of the study were to: (1) compare winds mapped by ground-based dual Doppler radars, airborne Doppler lidar, and anemometers on a tower; (2) compare measured atmospheric boundary layer flow with flows predicted by theoretical models; (3) investigate the kinematic structure of air mass boundaries that precede the development of severe storms; and (4) study the kinematic structure of thunderstorm phenomena (downdrafts, gust fronts, etc.) that produce wind shear and turbulence hazardous to aircraft operations. The report consists of three parts: Part 1, Intercomparison of Wind Data from Airborne Lidar, Ground-Based Radars and Instrumented 444 m Tower; Part 2, The Structure of the Convective Atmospheric Boundary Layer as Revealed by Lidar and Doppler Radars; and Part 3, Doppler Lidar Observations in Thunderstorm Environments.

  2. A prospective analysis of free flap monitoring techniques: physical examination, external Doppler, implantable Doppler, and tissue oximetry.

    PubMed

    Lohman, Robert F; Langevin, Claude-Jean; Bozkurt, Mehmet; Kundu, Neilendu; Djohan, Risal

    2013-01-01

    No universally accepted method of flap monitoring exists, and several techniques are in use. Repeated physical examination is most popular and is often supplemented with a handheld, external Doppler, and/or implantable Doppler probes; near-infrared spectroscopy is less commonly used. We investigated the nursing and resident house staff's experience and confidence with physical exam for flap monitoring. Also, a consecutive series of 38 patients with free flaps were monitored using physical examination, external Doppler, implantable arterial and venous Doppler probes, and near-infrared spectroscopy. Five patients developed signs of microvascular complications within 3 days of surgery; all were explored and salvaged. Neither the residents nor the nursing staff were universally trained or experienced in flap monitoring by physical exam. In all patients, changes in the appearance of the flap suggestive of a microvascular complication lagged 30 to 60 minutes after the adjunctive monitoring methods indicated that a problem had occurred. Near-infrared spectroscopy was the first warning sign in four of the five patients. Two patients were explored before thrombosis of the anastomoses occurred. Near-infrared spectroscopy may identify early microvascular complications more reliably than physical examination, external Doppler, or implantable Doppler.

  3. The recondite intricacies of Zeeman Doppler mapping

    NASA Astrophysics Data System (ADS)

    Stift, M. J.; Leone, F.; Cowley, C. R.

    2012-02-01

    We present a detailed analysis of the reliability of abundance and magnetic maps of Ap stars obtained by Zeeman Doppler mapping (ZDM). It is shown how they can be adversely affected by the assumption of a mean stellar atmosphere instead of appropriate 'local' atmospheres corresponding to the actual abundances in a given region. The essence of the difficulties was already shown by Chandrasekhar's picket-fence model. The results obtained with a suite of Stokes codes written in the ADA programming language and based on modern line-blanketed atmospheres are described in detail. We demonstrate that the high metallicity values claimed to have been found in chemically inhomogeneous (horizontally and vertically) Ap star atmospheres would lead to local temperature structures, continuum and line intensities, and line shapes that differ significantly from those predicted by a mean stellar atmosphere. Unfortunately, past applications of ZDM have consistently overlooked the intricate aspects of metallicity with their all-pervading effects. The erroneous assumption of a mean atmosphere for a spotted star can lead to phase-dependent errors of uncomfortably large proportions at varying wavelengths both in the Stokes I and V profiles, making precise mapping of abundances and magnetic field vectors largely impossible. The relation between core and wings of the Hβ line changes, too, with possible repercussions on the determination of gravity and effective temperature. Finally, a ZDM analysis of the synthetic Stokes spectra of a spotted star reveals the disturbing differences between the respective abundance maps based on a mean atmosphere on the one hand, and on appropriate 'local' atmospheres on the other. We then discuss what this all means for published ZDM results. Our discussion makes it clear that realistic local atmospheres must be used, especially if credible small-scale structures are to be obtained. Recondite: dealing with very profound, difficult or abstruse subject

  4. Doppler optical coherence tomography in cardiovascular physiology

    NASA Astrophysics Data System (ADS)

    Bonesi, M.; Meglinski, I.; Matcher, S.

    2008-09-01

    The study of flow dynamics in complex geometry vessels is highly important in many biomedical applications where the knowledge of the mechanic interactions between the moving fluid and the housing media plays a key role for the determination of the parameters of interest, including the effect of blood flow on the possible rupture of atherosclerotic plaques. Doppler Optical Coherence Tomography (DOCT), as a functional extension of Optical Coherence Tomography (OCT), is an optic, non-contact, non-invasive technique able to achieve detailed analysis of the flow/vessel interactions. It allows simultaneous high resolution imaging (10 μm typical) of the morphology and composition of the vessel and determination of the flow velocity distribution along the measured cross-section. We applied DOCT system to image high-resolution one-dimensional and multi-dimensional velocity distribution profiles of Newtonian and non-Newtonian fluids flowing in vessels with complex geometry, including Y-shaped and T-shaped vessels, vessels with aneurism, bifurcated vessels with deployed stent and scaffolds. The phantoms were built to mimic typical shapes of human blood vessels, enabling preliminary analysis of the interaction between flow dynamics and the (complex) geometry of the vessels and also to map the related velocity profiles at several inlet volume flow rates. Feasibility studies for quantitative observation of the turbulence of flows arising within the complex geometry vessels are discussed. In addition, DOCT technique was also applied for monitoring cerebral mouse blood flow in vivo. Two-dimensional DOCT images of complex flow velocity profiles in blood vessel phantoms and in vivo sub-cranial mouse blood flow velocities distributions are presented.

  5. Doppler optical coherence tomography in cardiovascular applications

    NASA Astrophysics Data System (ADS)

    Bonesi, M.; Matcher, S.; Meglinski, I.

    2010-06-01

    The study of flow dynamics in complex geometry vessels is highly important in various biomedical applications where the knowledge of the mechanic interactions between the moving fluid and the housing media plays a key role for the determination of the parameters of interest, including the effect of blood flow on the possible rupture of atherosclerotic plaques. Doppler Optical Coherence Tomography (DOCT), as a functional extension of Optical Coherence Tomography (OCT), is an optic, non-contact, noninvasive technique able to achieve detailed analysis of the flow/vessel interactions. It allows simultaneous high resolution imaging (˜10 µm typical) of the morphology and composition of the vessel and determination of the flow velocity distribution along the measured cross-section. We applied DOCT system to image high-resolution one-dimensional and multi-dimensional velocity distribution profiles of Newtonian and non-Newtonian fluids flowing in vessels with complex geometry, including Y-shaped and T-shaped vessels, vessels with aneurism, bifurcated vessels with deployed stent and scaffolds. The phantoms were built to mimic typical shapes of human blood vessels, enabling preliminary analysis of the interaction between flow dynamics and the (complex) geometry of the vessels and also to map the related velocity profiles at several inlet volume flow rates. Feasibility studies for quantitative observation of the turbulence of flows arising within the complex geometry vessels are discussed. In addition, DOCT technique was also applied for monitoring cerebral mouse blood flow in vivo. Two-dimensional DOCT images of complex flow velocity profiles in blood vessel phantoms and in vivo sub-cranial mouse blood flow velocities distributions are presented.

  6. Single Mode, Extreme Precision Doppler Spectrographs

    NASA Astrophysics Data System (ADS)

    Schwab, Christian; Leon-Saval, Sergio G.; Betters, Christopher H.; Bland-Hawthorn, Joss; Mahadevan, Suvrath

    2014-04-01

    The `holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a limiting factor in current multimode fiber fed instruments (Baudrand & Walker 2001), can be eliminated by proper design, and the diffraction limited input to the spectrograph allows for very compact instrument designs, which provide excellent optomechanical stability. A SMF is the ideal interface for new, very precise wavelength calibrators, like laser frequency combs (Steinmetz et al. 2008, Osterman et al. 2012), or SMF based Fabry-Perot Etalons (Halverson et al. 2013). At near infrared wavelengths, these technologies are ready to be implemented in on-sky instruments, or already in use. We discuss a novel concept for such a spectrograph.

  7. Transcranial Doppler sonography in fulminant hepatic failure.

    PubMed

    Abdo, A; López, O; Fernández, A; Santos, J; Castillo, J; Castellanos, R; González, L; Gómez, F; Limonta, D

    2003-08-01

    The clinical course of patients with fulminant hepatic failure (FHF) is often worsened by the presence of cerebral edema and endocranial hypertension. In spite of the multiple studies using Transcranial Doppler Sonography (TCDS), few have shown the cerebral blood flow (CBF) pattern among patients with encephalopathy resulting from FHF. Our objective was to characterize the CBF pattern in these patients through the use of TCDS to provide therapeutic strategies. The TCDS pattern was assessed in five patients diagnosed with FHF and compared with a control group who displayed critical neurologic conditions not associated with FHF. Pulsatile index, systolic, diastolic, and mean velocity of the middle cerebral artery were measured. The mean age of patients with FHF was 45.4 years. One hundred percent were women, with viral hepatitis as the predominant etiology. A cerebral hypoperfusion pattern was found in 80% of the FHF group and 40% of the control group. In the former group there was no evidence of hyperemia, as there was among 20% of the control group. The mean values of velocity and pulsatile index were 36.6 cm/sec and 2.4, respectively, in the FHF group and 47.8 cm/s and 1.8 in the control group (P=0.268, P=0.402). FHF patients show a predominance of cerebral hypoperfusion pattern with mean velocities lower than normal values and an increased pulsatile index. We recommend that clinicians take appropriate measures to improve cerebral perfusion and avoid hypoxia. Hyperventilation as a first level measure is contraindicated.

  8. Right Ventricular Tissue Doppler in Space Flight

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas R.; Barratt, Michael R.; Sargsyan, Ashot E.; Ebert, Douglas; Garcia, Kathleen M.; Martin, David S.; Dulchavsky, Scott A.; Duncan, J. Michael

    2009-01-01

    Tissue Doppler (TD) registers movement of a given sample of cardiac tissue throughout the cardiac cycle. TD spectra of the right ventricle (RV) were obtained from a long-duration ISS crewmember as a portion of an ongoing experiment ("Braslet" test objective). To our knowledge, this is the first report of RV TD conducted in space flight, and the data represent reproducibility and fidelity of this application in space and serve as the first "space normal" data set. Methods RV TD was performed by astronaut scientists remotely guided by an ultrasound expert from Mission Control Center, Houston, TX. In four of the subjects, RV TD was acquired from the free wall near the tricuspid annulus in two separate sessions 4 to 7 days apart. A fifth subject had only one session. All digital DICOM frames were exported for off-line analysis. Systolic (S ), early diastolic (E ) and late diastolic (A ) velocities were measured. RV Tei-index was calculated using diastolic and systolic time intervals as a combined measure of myocardial performance. Results and Discussion The mean values from the first 4 subjects (8 sessions) were used as the on-orbit reference data, and subject 5 was considered as a hypothetical patient for comparison (see Table). The greatest difference was in the early diastolic A (31 %) yet the standard deviation (a) for A amongst the reference subjects was 2.25 (mean = 16.02). Of interest is the Tei index, a simple and feasible indicator of overall ventricular function; it was similar amongst all the subjects. The late diastolic A seems to compensate for the variance in E . Normal Tei index for the RV is < 0.3, yet our data show all but one subject consistently above this level, notwithstanding their nominal responses to daily exercise in microgravity. These data remind us that the physiology of RV preload in altered gravity environments is still not completely understood.

  9. Hands-Free Transcranial Color Doppler Probe

    NASA Technical Reports Server (NTRS)

    Chin, Robert; Madala, Srihdar; Sattler, Graham

    2012-01-01

    Current transcranial color Doppler (TCD) transducer probes are bulky and difficult to move in tiny increments to search and optimize TCD signals. This invention provides miniature motions of a TCD transducer probe to optimize TCD signals. The mechanical probe uses a spherical bearing in guiding and locating the tilting crystal face. The lateral motion of the crystal face as it tilts across the full range of motion was achieved by minimizing the distance between the pivot location and the crystal face. The smallest commonly available metal spherical bearing was used with an outer diameter of 12 mm, a 3-mm tall retaining ring, and 5-mm overall height. Small geared motors were used that would provide sufficient power in a very compact package. After confirming the validity of the basic positioning concept, optimization design loops were completed to yield the final design. A parallel motor configuration was used to minimize the amount of space wasted inside the probe case while minimizing the overall case dimensions. The distance from the front edge of the crystal to the edge of the case was also minimized to allow positioning of the probe very close to the ear on the temporal lobe. The mechanical probe is able to achieve a +/-20deg tip and tilt with smooth repeatable action in a very compact package. The enclosed probe is about 7 cm long, 4 cm wide, and 1.8 cm tall. The device is compact, hands-free, and can be adjusted via an innovative touchscreen. Positioning of the probe to the head is performed via conventional transducer gels and pillows. This device is amendable to having advanced software, which could intelligently focus and optimize the TCD signal.

  10. Fetal and umbilical Doppler ultrasound in normal pregnancy

    PubMed Central

    Alfirevic, Zarko; Stampalija, Tamara; Gyte, Gillian ML

    2014-01-01

    Background One of the main aims of routine antenatal care is to identify the ‘at risk’ fetus in order to apply clinical interventions which could result in reduced perinatal morbidity and mortality. Doppler ultrasound study of umbilical artery waveforms helps to identify the compromised fetus in ‘high-risk’ pregnancies and, therefore, deserves assessment as a screening test in ‘low-risk’ pregnancies. Objectives To assess the effects on obstetric practice and pregnancy outcome of routine fetal and umbilical Doppler ultrasound in unselected and low-risk pregnancies. Search methods We searched the Cochrane Pregnancy and Childbirth Group Trials Register (May 2010). Selection criteria Randomised and quasi-randomised controlled trials of Doppler ultrasound for the investigation of umbilical and fetal vessels waveforms in unselected pregnancies compared to no Doppler ultrasound. Studies where uterine vessels have been assessed together with fetal and umbilical vessels have been included. Data collection and analysis Two authors independently assessed the studies for inclusion, assessed risk of bias and carried out data extraction. Main results We included five trials involving 14,185 women. The methodological quality of the trials was generally unclear because of insufficient data included in the reports. Routine fetal and umbilical Doppler ultrasound examination in low-risk or unselected populations did not result in increased antenatal, obstetric and neonatal interventions, and no overall differences were detected for substantive short term clinical outcomes such as perinatal mortality. There is no available evidence to assess the effect on substantive long term outcomes such as childhood neurodevelopment and no data to assess maternal outcomes, particularly psychological effects. Authors’ conclusions Existing evidence does not provide conclusive evidence that the use of routine umbilical artery Doppler ultrasound, or combination of umbilical and uterine

  11. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    SciTech Connect

    Showman, Adam P.; Lewis, Nikole K.; Fortney, Jonathan J.; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation-and Doppler signature-of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the {approx}2 km s{sup -1} blueshift inferred on HD 209458b may require drag time constants as short as 10{sup 4}-10{sup 6} s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  12. Doppler broadening induced spectral shift effects on reactor safety

    SciTech Connect

    Alapour, A.

    1980-01-01

    It is commonly accepted that the resonance reaction rate of any material increases when the temperature is raised. However, in a nuclear reactor the increase in resonance reaction rates with temperature at relatively high energy shifts the neutron spectrum in such a way that a net decrease in the neutron flux results at lower energies. This finding suggested that the spectral shift could significantly affect the Doppler reactivity change, warranting further investigations. The objective was to study the physical characteristics of this new phenomenon and its effects on reactor safety. The desirability of studying this effect was strengthened by the presence of discrepancies between the calculated and measured integral experiments. An exact Doppler broadening kernel, based on the Maxwellian distribution of nuclear velocities, and an accurate integral transport method NDCRAB, capable of including resonance overlap of all materials present in the reactor cell, were used in this study. The ZPR-6 Assembly 7 benchmark, a typical LMFBR reactor, was used to quantify the Doppler reactivity change for an increase in fuel temperature and to analyze the natural UO/sub 3/ sample Doppler worth in this assembly. The quantification of the various components of the Doppler reactivity change shows that the fissile material, /sup 239/Pu, has a large negative Doppler effect and contributes a large fraction to the total negative effect. The calculated Doppler effect of the natural UO/sub 3/ sample in this assembly was in good agreement with the measured value. The calculated and measured values for an increase in sample temperature from 293-0K to 1100/sup 0/K wre -0.887 Ih/kgU and -0.868 Ih/kgU.

  13. Doppler Signatures of the Atmospheric Circulation of Hot Jupiters

    NASA Astrophysics Data System (ADS)

    Showman, Adam P.; Fortney, J. J.; Lewis, N. K.; Shabram, M.

    2011-09-01

    To date, the exotic meteorology of hot Jupiters has primarily been characterized with thermal measurements, providing only indirect clues to the wind regime. Recently, however, Snellen et al. (2010) presented high-resolution groundbased transit spectra of HD209458b containing an apparent 2 km/sec blueshift, which they interpreted as a signature of atmospheric winds flowing from dayside to nightside toward Earth along the planet's terminator. Motivated by these observations, we describe the types of Doppler signatures generated by the atmospheric circulation and show how Doppler measurements can place powerful constraints on the meteorology. We show that, depending on parameters, the atmospheric circulation--and Doppler signature--of hot Jupiters splits into two regimes. At moderate stellar insolation, the day-night thermal forcing generates fast east-west jet streams from the interaction of standing planetary-scale waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a bimodal Doppler signature exhibiting distinct, superposed blue- and redshifted velocity peaks. Under more intense stellar insolation, however, the thermal forcing is so strong that it damps these planetary-scale waves, inhibiting their ability to generate jet streams. As a result, this second regime exhibits a circulation dominated primarily by high-altitude, day-to-night airflow along both terminators rather than longitudinally symmetric jets. This causes air to flow toward Earth along most of the terminator, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art 3D circulation models including nongrey radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that HD189733b lies in the first regime while HD209458b lies in the second regime. Moreover, we show how the amplitude of the Doppler

  14. The value of micro-Doppler in stereotactic brain biopsy.

    PubMed

    Hertel, F; Feiden, W; Bettag, M

    2005-06-01

    The aim of this study was to analyse the value of intraoperative micro-Doppler in stereotactic brain biopsy (SBB). So far, only a few studies have reported about the usefulness of micro-Doppler in stereotactic brain biopsy. Between 1998 and 2003, 155 SBBs were performed in 153 patients with micro-Doppler (81 males, 72 females, mean age: 59 years). All operations were performed using a ZD-frame and a multiplanar computer tomography-guided trajectory planning system (Leibinger SPP). A 16 MHz micro-Doppler probe (diameter 1 mm, DWL) was used in all cases to explore the area of biopsy before the tissue probes were taken. Serial biopsies (mean, 6 samples) were taken with the Sedan side-cutting cannula (n = 145) or the small forceps (n = 10). We evaluated the number of intraoperative detectable vessel signals by micro-Doppler, intraoperative bleedings as well as bleedings detected by postoperative CT (which was performed in all cases). We compared our results according to bleeding-related complications with the data of stereotactic biopsy series from the recent literature. A conclusive histopathological diagnosis was achieved in 150/153 patients (98 %). A re-biopsy had to be undertaken in 2 cases. In 98 biopsies (63 %), no vessel could be detected with the micro-Doppler. In the remainder, a signal of arterial vessels was detected in 22 (14 %) and a signal of venous vessels in 35 cases (23 %). Detection of a vessel in the micro-Doppler led to a change of the biopsy site in each case within the same trajectory. Biopsy-related bleedings were detected in 4 cases (2.6 %). Among these, the only bleeding which occurred without any signs of vessels in the micro-Doppler happened in a case of a melanoma. The overall biopsy-related permanent morbidity was 0.6 % (n = 1). The biopsy-related mortality was 0. Despite the overall high security of SBB, the use of intraoperative micro-Doppler may lead to an additional reduction of the risk for a biopsy-related bleeding without enormous

  15. Doppler ultrasound tracking instrument for monitoring blood flow velocity.

    PubMed

    von Krüger, Marco Antônio; Evans, David H

    2002-01-01

    Doppler ultrasound (US) is potentially a valuable method for monitoring changes of blood flow velocity over a period of many minutes or even hours, but is seldom used in this way. One difficulty that may have contributed to this is the problem of maintaining a fixed geometry between the US beam and the blood vessel. A method of improving the success of monitoring might be to actively steer the US beam so as to maintain an adequate signal even when small displacements of the transducer occur. We have designed and built a prototype system for this purpose. The system comprises a continuous-wave phased-array transducer controlled by a purpose-built Doppler unit. The system constantly evaluates the quality of the returning Doppler signal in terms of total power and signal-to-noise ratio (SNR) (evaluated by assessing the quality of derived envelope signals), and steers the ultrasonic beam in a manner so as to improve the signal, should this be necessary. The system was tested in vitro, where the automatic tracking of the Doppler signal doubled the effective beam width of the transducer. Further developments that increase sensitivity and steering range should result in US Doppler systems that are better suited to long-term monitoring.

  16. Temporal enhancement of two-dimensional color doppler echocardiography

    NASA Astrophysics Data System (ADS)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  17. Renal power Doppler ultrasonographic evaluation of children with acute pyelonephritis.

    PubMed

    Shajari, Ahmad; Nafisi-Moghadam, Reza; Malek, Mahrooz; Smaili, Agha; Fallah, Mahmud; Pahlusi, Ali

    2011-01-01

    Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.8 ± 2.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  18. GEOS 3 STDN S band Doppler tracking investigation

    NASA Technical Reports Server (NTRS)

    Rosenbaum, B.

    1979-01-01

    GEOS 3S Doppler band and laser ranging data, acquired from August 1975 to March 1976 in the spacecraft altimeter calibration area, are examined. An evaluation of two-way and three-way Doppler data, for the positioning of Spaceflight Tracking and Data Network S band stations is presented, as well as the Goddard Space Flight Center laser system that is used to reference the exact position of the Doppler stations. The two-way and three-way Doppler tracking devices, situated at Rosman and Bermuda, have yielded data for the recovery of GEOS 3 arc height with an uncertainty of only 1 m. Attention is given to the effects of beacon signal frequency instability, controlled by a temperature sensitive auxiliary crystal oscillator on board the spacecraft, and to the one-way range rate tracking noise that was found to be within a range of 2 to 10 cm/s. 1- and 2-way passes and their different arc meters are graphed, showing the Doppler tracking interval. It was concluded that other accurate computations and recovery of station coordinates could be performed employing tracking data from S band stations.

  19. Detector resolution in positron annihilation Doppler broadening experiments

    NASA Astrophysics Data System (ADS)

    Heikinheimo, J.; Ala-Heikkilä, J.; Tuomisto, F.

    2017-09-01

    Positron annihilation Doppler broadening spectroscopy characterizes lattice point defects and is sensitive to very small vacancy densities. High-purity germanium detectors are generally used for recording the Doppler broadening spectrum because they provide good energy resolution and stability. However, the energy resolution of a germanium detector is somewhat dependent on the photon absorption geometry in the detector crystal. This change in the energy resolution changes also the Doppler broadening parameters. To observe the dependency of the resolution function and the Doppler broadening parameters, we performed experiments on Si samples in standard sandwich configuration with a Na-22 source. We changed the radiation geometry of the incident gamma photons via altering the distance of the sample-source package from the detector and by adding steel between the source and the detector. We observed the change of the absorption geometry in the germanium detector crystal by doing Monte Carlo simulations. The aim of this study is to help understand and decide what is the best way to compare the Doppler broadening parameters obtained with different measurement setups and even with the same setup when the geometry in the measurements has changed.

  20. Short period ionospheric perturbations from continuous Doppler sounding

    NASA Astrophysics Data System (ADS)

    Fiser, Jiri; Chum, Jaroslav; Lastovicka, Jan; Buresova, Dalia

    2017-04-01

    Results of recent observations of ionospheric perturbations on short time scales obtained by international network (Czech Republic, Argentina, Taiwan and South Africa) of multipoint continuous Doppler sounders with time resolution about 10 s are presented. Examples of observation and analysis of propagation of gravity waves (GWs), equatorial spread F (ESF), infrasound from earthquake and large convective systems, as well as ionospheric perturbations caused by solar flares will be shown. It is documented that roughly poleward propagation of GWs dominates in the local summer, whereas mainly equatorward propagation is observed in the local winter. The analysis of occurrences and zonal drifts of ESF based on Doppler sounding are consistent with optical and satellite measurements. The observations of co-seismic perturbations by Doppler sounders in the vicinity of ionosondes and seismic sensors proved that the co-seismic perturbations are caused by approximately vertically propagating infrasound waves triggered by vertical motion of the ground surface. Numerical simulations and Doppler measurements confirmed that in the vicinity (up to about 1000 km) from epicenters of strong earthquake, the infrasound propagates in nonlinear regime in the upper atmosphere, which results in the formation of N-shaped pulse. Solar flares are observed both as sudden frequency deviations and amplitude attenuations of Doppler signal.

  1. Intraluminal ultrasound intensity distribution and backscattered Doppler power.

    PubMed

    Thompson, Rosemary S; Bambi, Giacomo; Steel, Robin; Tortoli, Piero

    2004-11-01

    Ultrasound (US) incident obliquely on a cylindrical vessel is redistributed in space when the propagation path includes walls with acoustic impedance different from that of the surrounding media. We investigated this using low-density polyethylene (PE) as the vessel wall material. Both simulations and experiments were carried out. Direct hydrophone measurements of the acoustic field were made within a half section of the PE tube, and the distribution of backscattered Doppler power along a scan line was obtained using a range-Doppler instrument. Both simulation and hydrophone results demonstrate lateral shadow regions within the lumen. In every one of various Doppler flow experiments conducted, the backscattered Doppler power, compensated for on-axis transducer behaviour, increased with depth. Simulation results for an incident continuous-wave (CW) plane wave show that it tends to be focused by the curvature of the PE tube walls. The wall interactions are, however, angle-dependent and so the behaviour of a focused US beam depends on the beam as well as the walls. This study demonstrates alterations in the spatial distribution of US within a cylindrical vessel as a result of known vessel wall properties. It also provides evidence that local intensity variations within the lumen affect the relative Doppler power backscattered from small sample volumes.

  2. Results of the international ionospheric Doppler sounder network

    NASA Astrophysics Data System (ADS)

    Lastovicka, Jan; Chum, Jaroslav

    2016-07-01

    This paper summarizes main recent results reached by the Czech-lead international network of ionospheric Doppler sounders. The network consists of Doppler sounders in the western half of Czechia (5 measuring paths, 3 frequencies with central receivers in Prague), northern Taiwan (3 transmitters, two separated receivers, 1 frequency), and three similar systems (3 measuring paths with 1 receiver and 1 frequency) in Tucuman (north-western Argentina), Hermanus (the southernmost South Africa) and Luisville (northern South Africa). Three main areas of research have been (1) statistical properties of gravity waves, (2) ionospheric effects of earthquakes, and (3) low latitude/equatorial phenomena. Some results: (1) the theoretically expected dominance of gravity wave propagation against wind has been confirmed; (2) impact of the Tohoku 2001 M9.0 earthquake was registered in the ionosphere over the Czech Republic as long-period infrasound on the distance of about 9000 km from epicenter; analysis of ionospheric infrasound excited by the Nepal 2015 M7.8 earthquake observed by the Czech and Taiwan Doppler sounders showed that the intensity of ionospheric signal is significantly height dependent and that the Doppler shift depends not only on the advection (up and down motion) of the reflecting layer but also on the compression/rarefaction of the electron gas; (3) spread F structures observed by Doppler sounders in Tucuman and Taiwan (both under the crest of equatorial ionization anomaly) provide results consistent with S4 scintillation data and with previous optical, GPS and satellite measurements.

  3. Doppler Feature Based Classification of Wind Profiler Data

    NASA Astrophysics Data System (ADS)

    Sinha, Swati; Chandrasekhar Sarma, T. V.; Lourde. R, Mary

    2017-01-01

    Wind Profilers (WP) are coherent pulsed Doppler radars in UHF and VHF bands. They are used for vertical profiling of wind velocity and direction. This information is very useful for weather modeling, study of climatic patterns and weather prediction. Observations at different height and different wind velocities are possible by changing the operating parameters of WP. A set of Doppler power spectra is the standard form of WP data. Wind velocity, direction and wind velocity turbulence at different heights can be derived from it. Modern wind profilers operate for long duration and generate approximately 4 megabytes of data per hour. The radar data stream contains Doppler power spectra from different radar configurations with echoes from different atmospheric targets. In order to facilitate systematic study, this data needs to be segregated according the type of target. A reliable automated target classification technique is required to do this job. Classical techniques of radar target identification use pattern matching and minimization of mean squared error, Euclidean distance etc. These techniques are not effective for the classification of WP echoes, as these targets do not have well-defined signature in Doppler power spectra. This paper presents an effective target classification technique based on range-Doppler features.

  4. Long duration meteor echoes characterized by Doppler spectrum bifurcation

    NASA Astrophysics Data System (ADS)

    Bourdillon, A.; Haldoupis, C.; Hanuise, C.; Le Roux, Y.; Menard, J.

    2005-03-01

    We report on a new category of long lasting meteor echoes observed occasionally with HF and VHF radars. These meteoric returns, which have lifetimes from many seconds to a few minutes, are characterized by a distinct Doppler spectral signature showing a pronounced Doppler bifurcation which includes narrow bands of discrete Doppler velocities, often of opposite polarity. The large signal to noise ratios and the narrowness of the spectra imply that coherent or Bragg scattering is not of relevance here, therefore these echoes do not associate with the long living meteor-induced backscatter (MIB) from the lower E region. A reasonable interpretation needs to explain both the Doppler spectrum bifurcation and the long echo duration. As such, we propose the idea of a structured vertical wind shear in the lower E region which traps different fragments of a meteor trail plasma in the same way that sporadic E layers form. These trail parts inside the shear-related wind profile may act as relatively long-lasting meteoric reflectors moving with different Doppler velocities, also of opposite polarity.

  5. Response of a Doppler canceling system to plane gravitational waves

    NASA Technical Reports Server (NTRS)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for a gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-cancelled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  6. Response of a Doppler canceling system to plane gravitational waves

    NASA Technical Reports Server (NTRS)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for a gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-cancelled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  7. A rotating torus phantom for assessing color Doppler accuracy.

    PubMed

    Stewart, S F

    1999-10-01

    A rotating torus phantom was designed to assess the accuracy of color Doppler ultrasound. A thin rubber tube was filled with blood analog fluid and joined at the ends to form a torus, then mounted on a disk submerged in water and rotated at constant speeds by a motor. Flow visualization experiments and finite element analyses demonstrated that the fluid accelerates quickly to the speed of the torus and spins as a solid body. The actual fluid velocity was found to be dependent only on the motor speed and location of the sample volume. The phantom was used to assess the accuracy of Doppler-derived velocities during two-dimensional (2-D) color imaging using a commercial ultrasound system. The Doppler-derived velocities averaged 0.81 +/- 0.11 of the imposed velocity, with the variations significantly dependent on velocity, pulse-repetition frequency and wall filter frequency (p < 0.001). The torus phantom was found to have certain advantages over currently available Doppler accuracy phantoms: 1. It has a high maximum velocity; 2. it has low velocity gradients, simplifying the calibration of 2-D color Doppler; and 3. it uses a real moving fluid that gives a realistic backscatter signal.

  8. Selection functions in doppler planet searches

    NASA Astrophysics Data System (ADS)

    O'Toole, S. J.; Tinney, C. G.; Jones, H. R. A.; Butler, R. P.; Marcy, G. W.; Carter, B.; Bailey, J.

    2009-01-01

    We present a preliminary analysis of the sensitivity of Anglo-Australian Planet Search data to the orbital parameters of extrasolar planets. To do so, we have developed new tools for the automatic analysis of large-scale simulations of Doppler velocity planet search data. One of these tools is the two-dimensional Keplerian Lomb-Scargle (LS) periodogram that enables the straightforward detection of exoplanets with high eccentricities (something the standard LS periodogram routinely fails to do). We used this technique to redetermine the orbital parameters of HD20782b, with one of the highest known exoplanet eccentricities (e = 0.97 +/- 0.01). We also derive a set of detection criteria that do not depend on the distribution functions of fitted Keplerian orbital parameters (which we show are non-Gaussian with pronounced, extended wings). Using these tools, we examine the selection functions in orbital period, eccentricity and planet mass of Anglo-Australian Planet Search data for three planets with large-scale Monte Carlo like simulations. We find that the detectability of exoplanets declines at high eccentricities. However, we also find that exoplanet detectability is a strong function of epoch-to-epoch data quality, number of observations and period sampling. This strongly suggests that simple parametrizations of the detectability of exoplanets based on `whole-of-survey' metrics may not be accurate. We have derived empirical relationships between the uncertainty estimates for orbital parameters that are derived from least-squares Keplerian fits to our simulations and the true 99 per cent limits for the errors in those parameters, which are larger than equivalent Gaussian limits by the factors of 5-10. We quantify the rate at which false positives are made by our detection criteria, and find that they do not significantly affect our final conclusions. And finally, we find that there is a bias against measuring near-zero eccentricities, which becomes more significant

  9. Cardiac tissue Doppler imaging in sports medicine.

    PubMed

    Krieg, Anne; Scharhag, Jürgen; Kindermann, Wilfried; Urhausen, Axel

    2007-01-01

    The differentiation of training-induced cardiac adaptations from pathological conditions is a key issue in sports cardiology. As morphological features do not allow for a clear delineation of early stages of relevant pathologies, the echocardiographic evaluation of left ventricular function is the technique of first choice in this regard. Tissue Doppler imaging (TDI) is a relatively recent method for the assessment of cardiac function that provides direct, local measurements of myocardial velocities throughout the cardiac cycle. Although it has shown a superior sensitivity in the detection of ventricular dysfunction in clinical and experimental studies, its application in sports medicine is still rare. Besides technical factors, this may be due to a lack in consensus on the characteristics of ventricular function in relevant conditions. For more than two decades there has been an ongoing debate on the existence of a supernormal left ventricular function in athlete's heart. While results from traditional echocardiography are conflicting, TDI studies established an improved diastolic function in endurance-trained athletes with athlete's heart compared with controls.The influence of anabolic steroids on cardiac function also has been investigated by standard echocardiographic techniques with inconsistent results. The only TDI study dealing with this topic demonstrated a significantly impaired diastolic function in bodybuilders with long-term abuse of anabolic steroids compared with strength-trained athletes without abuse of anabolic steroids and controls, respectively.Hypertrophic cardiomyopathy is the most frequent cause of sudden death in young athletes. However, in its early stages, it is difficult to distinguish from athlete's heart. By means of TDI, ventricular dysfunction in hypertrophic cardiomyopathy can be disclosed even before the development of left ventricular hypertrophy. Also, a differentiation of left ventricular hypertrophy due to hypertrophic

  10. Signal processing considerations for low signal to noise ratio laser Doppler and phase Doppler signals

    NASA Technical Reports Server (NTRS)

    Ibrahim, K. M.; Wertheimer, G. D.; Bachalo, William D.

    1991-01-01

    The relative performance of current methods used for estimating the phase and the frequency in LDV and phase Doppler applications in low signal to noise ratio conditions is analyzed. These methods include the Fourier analysis and the correlation techniques. Three methods that use the correlation function for frequency and phase estimations are evaluated in terms of accuracy and speed of processing. These methods include: (1) the frequency estimation using zero crossings counting of the auto-correlation function, (2) the Blackman-Tukey method, and (3) the AutoRegressive method (AR). The relative performance of these methods is evaluated and compared with the Fourier analysis method which provides the optimum performance in terms of the Maximum Likelihood (ML) criteria.

  11. Manipulating the spin-dependent splitting by geometric Doppler effect.

    PubMed

    Liu, Yachao; Ke, Yougang; Zhou, Junxiao; Luo, Hailu; Wen, Shuangchun

    2015-06-29

    We report the manipulation of spin-dependent splitting by geometric Doppler effect based on dielectric metasurfaces. The extrapolation of rotational Doppler effect from temporal to spatial coordinate gives the phase change when the local optical axes of dielectric metasurfaces are rotating in space. Therefore, the continuous variation of local optical axes in a certain direction will introduce a phase gradient in the same direction at the beam cross section. This is additive to the phase gradient appeared when breaking the rotational symmetry of linearly polarized cylindrical vector beams, which leads to the deflections of different spin components of light, i.e., photonic spin Hall effect. Hence, it is possible to manipulate the spin-dependent splitting by introducing the geometric Doppler effect. Theoretically and experimentally, we show that the magnitude and orientation of the spin-dependent splitting are both tunable when changing the spatial rotation rate of local optical axes and incident polarization.

  12. Theoretical analysis and experimental verification on optical rotational Doppler effect.

    PubMed

    Zhou, Hailong; Fu, Dongzhi; Dong, Jianji; Zhang, Pei; Zhang, Xinliang

    2016-05-02

    We present a theoretical model to sufficiently investigate the optical rotational Doppler effect based on modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the difference of mode index between input and output orbital angular momentum (OAM) light, and linear to the rotating speed of spinning object as well. An experiment is carried out to verify the theoretical model. We explicitly suggest that the spatial spiral phase distribution of spinning object determines the frequency content. The theoretical model makes us better understand the physical processes of rotational Doppler effect, and thus has many related application fields, such as detection of rotating bodies, imaging of surface and measurement of OAM light.

  13. Rotational Doppler Effect: A Probe for Molecular Orbitals Anisotropy.

    PubMed

    Miao, Quan; Travnikova, Oksana; Gel'mukhanov, Faris; Kimberg, Victor; Sun, Yu-Ping; Thomas, T Darrah; Nicolas, Christophe; Patanen, Minna; Miron, Catalin

    2015-05-07

    The vibrationally resolved X-ray photoelectron spectra of X2Σg+(3σg−1) and B2Σu+(2σu−1) states of N2+ were recorded for different photon energies and orientations of the polarization vector. Clear dependencies of the spectral line widths on the X-ray polarization as well as on the symmetry of the final electronic states are observed. Contrary to the translational Doppler, the rotational Doppler broadening is sensitive to the photoelectron emission anisotropy. On the basis of theoretical modeling, we suggest that the different rotational Doppler broadenings observed for gerade and ungerade final states result from a Young's double-slit interference phenomenon.

  14. One way Doppler Extractor. Volume 2: Digital VCO technique

    NASA Technical Reports Server (NTRS)

    Nossen, E. J.; Starner, E. R.

    1974-01-01

    A feasibility analysis and trade-offs for a one-way Doppler extractor using digital VCO techniques is presented. The method of Doppler measurement involves the use of a digital phase lock loop; once this loop is locked to the incoming signal, the precise frequency and hence the Doppler component can be determined directly from the contents of the digital control register. The only serious error source is due to internally generated noise. Techniques are presented for minimizing this error source and achieving an accuracy of 0.01 Hz in a one second averaging period. A number of digitally controlled oscillators were analyzed from a performance and complexity point of view. The most promising technique uses an arithmetic synthesizer as a digital waveform generator.

  15. Modeling and processing of laser Doppler reactive hyperaemia signals

    NASA Astrophysics Data System (ADS)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  16. Phase relation recovery for scanning laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Alveringh, D.; Sanders, R. G. P.; Wiegerink, R. J.; Lötters, J. C.

    2017-02-01

    Laser Doppler vibrometers are able to measure the velocity of a single point compared to a reference point by analyzing the Doppler shift of the laser beams. In many commercially available laser Doppler vibrometers, the laser point can be scanned to obtain an out-of-plane velocity profile of a surface. It is essential that the phase information of the velocities between points is measured as well to be able to fully reproduce the velocity profile of the surface. If this cannot be done by triggering on the actuation signal, the proposed two stage method can be used. This method measures the surface in two stages: one scan with the reference beam at a fixed point and one scan with the reference beam on a moving point. The algorithm in this article calculates the phase and reconstructs the velocity of each point. This is experimentally verified on three different micro structures. The postprocessing algorithm is not intensive in computing power.

  17. Spaceborne Doppler Precipitation Radar: System Configurations and Performance Analysis

    NASA Technical Reports Server (NTRS)

    Tanelli, Simone; Im, Eastwood

    2004-01-01

    Knowledge of the global distribution of the vertical velocity of precipitation is important in in the study of energy transportation in the atmosphere, the climate and weather. Such knowledge can only be directly acquired with the use of spaceborne Doppler precipitation radars. Although the high relative speed of the radar with respect to the rainfall particles introduces significant broadening in the Doppler spectrum, recent studies have shown that the average vertical velocity can be measured to acceptable accuracy levels by appropriate selection of radar parameters. Furthermore, methods to correct for specific errors arising from NUBF effects and pointing uncertainties have recently been developed. In this paper we will present the results of the trade studies on the performances of a spaceborne Doppler radar with different system parameters configurations.

  18. Rate the merits of pseudo-Doppler direction finding

    NASA Astrophysics Data System (ADS)

    Oden, Clark

    1989-03-01

    It is pointed out that periodically sampling antennas in pseudo-Doppler direction-finding (DF) systems create numerous sidebands above and below the receiving carrier. When sidebands of multiple incoming signals interfere with one another, false readings often result. As the receiver samples antennas, the process modulates the incoming signal's amplitude. In such DF systems, square-wave AM radically widens the detected signal's frequency span. Ways of reducing the bandwidth of the sampled signals are briefly discussed. Advantages and disadvantages of implementing pseudo-Doppler systems over other DF systems are weighed. It is concluded that pseudo-Doppler DFs should be considered only when the system's cost or complexity must be limited and the detected signals are not in a crowded portion of the RF spectrum.

  19. Improved technique for blood flow velocity measurement using Doppler effect

    NASA Astrophysics Data System (ADS)

    Valadares Oliveira, Eduardo J.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.

    2002-04-01

    The Doppler velocimeter developed allows to determine the angle between the ultrasonic beam and the velocity vector of the flow, and to calculate the precise blood flow in a vessel. Four piezoelectric transducers constitute the Doppler velocimeter. Three of these transducers are positioned to form an equilateral triangle (base of a pyramid). When these transducers move simultaneously, backward or forward from the initial position, the emitted ultrasonic beams focalize on a position (peak of the pyramid) closer or farther from the transducers faces, according to the depth of the vessel where we intend to measure de flow. The angle between the transducers allows adjusting the height of this pyramid and the position of the focus (where the three beams meet). A forth transducer is used to determine the diameter of the vessel and monitor the position of the Doppler velocimeter relative to the vessel. Simulation results showed that with this technique is possible to accomplish precise measurement of blood flow.

  20. Pulsed Doppler on a vaginal probe. Necessity, convenience, or luxury?

    PubMed

    Schaaps, J P; Soyeur, D

    1989-06-01

    One hundred twenty-seven pregnancies were studied between 5 and 12 weeks of amenorrhea with Doppler ultrasound coupled with a vaginal probe. These biologically proven pregnancies had no clinical sign of abnormality; however, 29 were detected not to be evolving. Doppler signals were obtained from the embryonic heart, umbilical cord, trophoblastic crown, peritrophoblastic area, and from the uterine and ovarian arteries. In normally evolving pregnancies, no intratrophoblastic flow was detected, whereas it was present in all missed abortions. The peritrophoblastic area always generates a Doppler signal with an important diastolic component. The resistance index (RI) of uterine arteries was constant during the first trimester of pregnancy (RI = .77 +/- .15) and a protodiastolic notch was found in 58% of the cases. The combined use of these two modalities of examination was demonstrated. Although the clinical efficacy of the method has not yet been demonstrated, this combination of techniques opens new perspectives to echography and adds a dynamic dimension to morphologic studies.

  1. Doppler Cooling Trapped Ions with a UV Frequency Comb.

    PubMed

    Davila-Rodriguez, Josue; Ozawa, Akira; Hänsch, Theodor W; Udem, Thomas

    2016-01-29

    We demonstrate Doppler cooling of trapped magnesium ions using a frequency comb at 280 nm obtained from a frequency tripled Ti:sapphire laser. A comb line cools on the 3s_{1/2}-3p_{3/2} transition, while the nearest blue-detuned comb line contributes negligible heating. We observe the cooling-heating transition and long-term cooling of ion chains with several sympathetically cooled ions. Spatial thermometry shows that the ion is cooled to near the Doppler limit. Doppler cooling with frequency combs has the potential to open many additional atomic species to laser cooling by reaching further into the vacuum and extreme ultraviolet via high-harmonic generation and by providing a broad bandwidth from which multiple excitation sidebands can be obtained.

  2. Micro-range micro-doppler for dismount classification

    NASA Astrophysics Data System (ADS)

    Tahmoush, Dave

    2013-05-01

    This paper presents a processing technique that can be used to detect and classify pedestrians group based on the micro- Doppler signature gathered with a millimeter wave radar. The evaluation of the number of pedestrians moving in a group can be a difficult task using a traditional micro-Doppler spectrogram because of a tendency for people to partially synchronize their steps when walking together. The new approach, based on multi-range variation as well as the micro-Doppler variations, provides promising results. The range-spectrogram processing technique was developed and tested using a database composed of hundreds of pedestrian and vehicle signatures gathered in an urban test site over a two year period in a variety of weather conditions. We associate image detections with radar detections through motion extracted from both radar and imagery. We also explain how radar and video together can produce an inexpensive alternative to 3-D imaging.

  3. Automatic human micro-Doppler signature separation by Hough transform

    NASA Astrophysics Data System (ADS)

    Zhang, Jun; Jin, Tian; Qiu, Lei; Zhou, Zhimin

    2015-12-01

    The micro-Doppler signature is one of the most prominent information for target classification and identification. As Hough transform (HT) is an efficient tool for detecting weak straight target traces in the image, an HT based algorithm is proposed for micro-Doppler signature separation of multiple persons. Few seconds data is processed at one time to ensure human motion traces approximate to straight lines in the radar slow time-range image. Taking HT to the slow time-range image, each human's motion trace can be recovered through recursively searching the peaks in HT space. Applying time-frequency transform to the range cells around each recovered line, the human micro-Doppler signature can be achieved and separated. Experimental results are given to illustrate the validity of the proposed algorithm.

  4. Imaging nanoparticle flow using magneto-motive optical Doppler tomography.

    PubMed

    Kim, Jeehyun; Oh, Junghwan; Milner, Thomas E; Nelson, J Stuart

    2007-01-24

    We introduce a novel approach for imaging solutions of superparamagnetic iron oxide (SPIO) nanoparticles using magneto-motive optical Doppler tomography (MM-ODT). MM-ODT combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect nanoparticles flowing through a microfluidic channel. A solenoid with a cone-shaped ferrite core extensively increased the magnetic field strength (B(max) = 1 T, [Formula: see text]) at the tip of the core and also focused the magnetic field in microfluidic channels containing nanoparticle solutions. Nanoparticle contrast was demonstrated in a microfluidic channel filled with an SPIO solution by imaging the Doppler frequency shift which was observed independently of the nanoparticle flow rate and direction. Results suggest that MM-ODT may be applied to image Doppler shift of SPIO nanoparticles in microfluidic flows with high contrast.

  5. An introduction and guide to effective Doppler assessment.

    PubMed

    Benbow, Maureen

    2014-12-01

    Accurate and timely diagnosis of leg ulceration is an essential factor in making evidence-based, effective decisions regarding patient management with the aim of swift wound healing and/or referral to the appropriate specialty. Nurses are professionally responsible for ensuring that patients receive the appropriate assessment and evidence-based management. This article examines the most up-to-date guidance on Doppler ultrasound as a key element of this assessment. Approaches to assessment will be explored, with emphasis on the need to include a Doppler ultrasound as one key element of a larger, holistic assessment. An introduction to the ankle-brachial pressure index (ABPI) will be given, followed by a step-by-step guide to standard procedures for carrying out a full Doppler ultrasound. Alternative options for measuring ABPI are also provided.

  6. Doppler spectroscopy, a powerful tool for studying molecular collision dynamics

    SciTech Connect

    Mestdagh, J.M.; Visticot, J.P.

    1994-12-31

    The present review describes the application of Doppler spectroscopy to studies in collision dynamics. The method was originally introduced by Kinsey (J. Chem. Phys. 66, 2560 (1976)). The authors used it to obtain angular and velocity distributions of Ba(6s6p{sup 1}P{sub 1}) atoms scattered in the 6s6p{sup 3}P{sub 2} level by collisions with argon and simple molecules. After a short review of their recent work, the authors outline those areas where Doppler spectroscopy is a valuable tool (sometimes the only tool) for exploring gas phase collision dynamics. In particular they make clear that Doppler spectroscopy should not be considered as alternative but rather as complementary to the standard way of measuring differential cross sections where a rotating mass spectrometer rather than laser induced fluorescence is used to detect the scattered particles.

  7. All-sky Doppler interferometer for thermospheric dynamics studies

    NASA Astrophysics Data System (ADS)

    Biondi, Manfred A.; Zipf, Mark E.; Sipler, Dwight P.; Baumgardner, Jeffrey L.

    1995-04-01

    An efficient, all-sky input optical system has been mated to a 100-mm-aperture Fabry-Perot interferometer that employs a cooled (-150 deg C) CCD as a photon detector to create an all-sky Doppler interferom-eter. The instrument is capable of simultaneously measuring Doppler shifts and widths of nightglow emission lines from many different points in the sky, thereby providing determinations of upper-atmosphere neutral wind and temperature fields over a large region (to approximately equals 2000 km in extent). For OI 630-nm (thermosphere) and OH 799.6-nm (mesopause) nightglow emissions, exposure times of 5-15 min provide good-quality interferometric images. The capability of the all-sky Doppler interferometer is illustrated by examples of thermospheric wind and temperature fields measured over Millstone Hill, Massachusetts.

  8. Browsing a wealth of millimeter-wavelength doppler spectra data

    SciTech Connect

    Johnson,K.; Luke,E.; Kollias, P.; Remillard, J.; Widener, K.; Jensen, M.

    2010-03-15

    The ARM Climate Research Facility has collected an extensive archive of vertically pointing millimeter wavelength Doppler radar spectra at both 35 and 95 GHz. These data are a rich potential source of detailed microphysical and dynamical cloud and precipitation information. The recording of spectra, which is ongoing, began at the Southern Great Plains site in September of 2003, at the North Slope of Alaska site in April 2004, and at Tropical Western Pacific sites in 2006. Spectra are also being collected during ARM Mobile Facility deployments. The data’s temporal resolution is as high as two seconds, at height intervals of 45 to 90 m. However, the sheer volume of available data can be somewhat daunting to access and search for specific features of interest. Here we present a user interface for spectra browsing, which allows the user to view time-height images of radar moments, select a time or height of interest, and then “drill down” through images of spectrograms to individual Doppler spectra or time- and height-sequences of spectra. Also available are images summarizing spectral characteristics, such as number of spectral peaks, spectral shape information (skewness and kurtosis), moment uncertainty estimates, and hydrometeor vs. clutter identification as produced by the ARM MicroARSCL (Microphysical Active Remote Sensing of Clouds) value-added product. In addition to the access and visualization tools, we are developing a Doppler spectra simulator capable of generating Doppler spectra from liquid, mixed-phase, and solid cloud constituents and precipitation. The Doppler spectra simulator can be used as an interface between explicit microphysics models and Doppler spectra observations from the ARM radars. The plan is to ultimately make the spectra simulator available from within the spectra browser, allowing a user to associate observed spectra with the microphysical conditions capable of producing them.

  9. Reducing Antenna Mechanical Noise in Precision Doppler Tracking

    NASA Astrophysics Data System (ADS)

    Armstrong, J. W.; Estabrook, F. B.; Asmar, S. W.; Iess, L.; Tortora, P.

    2006-05-01

    Precision Doppler tracking of deep-space probes is central to spacecraft navigation and many radio science investigations. The most sensitive Doppler observations to date have been taken using the NASA/JPL Deep Space Network (DSN) antenna DSS 25, a 34-m-diameter beam-waveguide station especially instrumented with simultaneous X-band (approximately 8.4-GHz) and Ka-band (approximately 32-GHz) links and tropospheric scintillation calibration equipment, tracking the Cassini spacecraft. These Cassini observations achieved Doppler fractional frequency stability (Doppler frequency fluctuation divided by center frequency, Delta f / f_o ) of approximately 3 x 10^-15 at tau = 1000 s integration. In those very-high-sensitivity tracks, the leading disturbance was antenna mechanical noise: time-dependent unmodeled physical motion of the ground antenna's phase center caused by antenna sag as the elevation angle changed, unmodeled subreflector motion, wind loading, bulk motion of the antenna as it rolled over irregularities in the supporting azimuth ring, differential thermal expansion of the structure, etc. This noise has seemed irreducible at reasonable cost, since it is unclear how to build a practical, large, moving, steel structure having mechanical stability significantly better than that of current tracking stations. Here we show how the mechanical noise of a large tracking antenna can effectively be removed when two-way Doppler tracking data from an existing DSN antenna are suitably combined with simultaneous tracking data using an ancillary (smaller and stiffer) antenna. Using our method, the mechanical noise in the final Doppler observable can be reduced, substantially, to that of the stiffer antenna.

  10. A new clutter rejection algorithm for Doppler ultrasound.

    PubMed

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2003-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): time-varying low-frequency components, covering systole and early diastole, and short transient clutter signals, distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted from the time-domain signal s(n) until the signal-to-clutter (S/C) ratio reached a maximum. For the low-frequency clutter signal, the improvement in S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient clutter signal, ten atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. The performance of the MP method was also tested on real data recorded over the common carotid artery of a normal subject. Removing 15 atoms significantly improved the appearance of the Doppler sonogram contaminated with low-frequency clutter. Many more atoms (over 200) were required to remove transient clutter components. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  11. Doppler displacements in kink MHD waves in solar flux tubes

    NASA Astrophysics Data System (ADS)

    Goossens, Marcel; Van Doorsselaere, Tom; Terradas, Jaume; Verth, Gary; Soler, Roberto

    Doppler displacements in kink MHD waves in solar flux tubes Presenting author: M. Goossens Co-authors: R. Soler, J. Terradas, T. Van Doorsselaere, G. Verth The standard interpretation of the transverse MHD waves observed in the solar atmosphere is that they are non-axisymmetric kink m=1) waves on magnetic flux tubes. This interpretation is based on the fact that axisymmetric and non-axisymmetric fluting waves do not displace the axis of the loop and the loop as a whole while kink waves indeed do so. A uniform transverse motion produces a Doppler displacement that is constant across the magnetic flux tube. A recent development is the observation of Doppler displacements that vary across the loop. The aim of the present contribution is to show that spatial variations of the Doppler displacements across the loop can be caused by kink waves. The motion associated with a kink wave is purely transverse only when the flux tube is uniform and sufficiently thin. Only in that case do the radial and azimuthal components of displacement have the same amplitude and is the azimuthal component a quarter of a period ahead of the radial component. This results in a unidirectional or transverse displacement. When the flux tube is non-uniform and has a non-zero radius the conditions for the generation of a purely transverse motion are not any longer met. In that case the motion in a kink wave is the sum of a transverse motion and a non-axisymmetric rotational motion that depends on the azimuthal angle. It can produce complicated variations of the Doppler displacement across the loop. I shall discuss the various cases of possible Doppler displacenents that can occur depending on the relative sizes of the amplitudes of the radial and azimuthal components of the displacement in the kink wave and on the orientation of the line of sight.

  12. Comparison between oscillometric- and Doppler-ABI in elderly individuals.

    PubMed

    Takahashi, Ikuno; Furukawa, Kyoji; Ohishi, Waka; Takahashi, Tetsuya; Matsumoto, Masayasu; Fujiwara, Saeko

    2013-01-01

    Peripheral arterial disease (PAD) generally remains under-recognized, mainly due to the specialized technical skills required to detect the low values of the ankle-brachial index (ABI). As a simpler and faster alternative to the standard method using continuous-wave Doppler ultrasound, we evaluated automated oscillometric ABI measurement by VP-2000 with an elderly cohort of 113 subjects (age range, 61 to 88 years). The standard deviation in ABIs measured by the Doppler method was statistically greater than that measured by the oscillometric method for each of the two legs (P < 0.001). Correlations in ABIs between the two methods were 0.46 for the left leg and 0.61 for the right leg; this result appears to have been caused by interobserver variation in the Doppler ABI measurements. While the trend showing greater differences between average oscillometric- and Doppler-ABIs was significant at the lower ABI ranges, there was little indication of differences in measurements having an average ABI > 1.1. The difference between the methods was suggestively larger in subjects who were smokers than in non-smokers (P = 0.09), but the difference was not affected by other potential atherosclerotic risk factors, including age at examination (P > 0.50). A larger difference at lower ABIs led to better PAD detection by the Doppler method compared to the oscillometric method (sensitivity = 50%, specificity = 100%), although the overall agreement was not small (Cohen's Kappa = 0.65). Our findings indicate that oscillometric devices can provide more accurate estimation of the prevalence of PAD in elderly individuals than the conventional Doppler method.

  13. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    PubMed Central

    2015-01-01

    Purpose: The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. Methods: Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. Results: The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds) and conventional (231±117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds) required a shorter time than conventional Doppler US (381±133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. Conclusion: UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up. PMID:25409662

  14. The case of the Doppler effect for photons revisited

    NASA Astrophysics Data System (ADS)

    Redžić, Dragan V.

    2013-11-01

    A detailed account is presented of the Doppler effect as a photon phenomenon, complementing a recent paper by Giuliani (2013 Eur. J. Phys. 34 1035-47). The essence of Schrödinger's pioneering derivation (1922 Phys. Z. 23 301-3) of a Doppler formula in terms of the corpuscular theory of light, using energy-momentum conservation, is related. Some neglected references that put the whole scene around the Ives-Stilwell experiment into a more precise perspective are highlighted. Atoms as clocks and particle-wave complementarity are also discussed briefly.

  15. Doppler echocardiographic parameters of evaluation of left ventricular systolic function.

    PubMed

    Drăgulescu, S I; Roşu, D; Abazid, J; Ionac, A

    1993-01-01

    The authors suggest a new method using Doppler echocardiography for the evaluation of cardiac performance. Doppler echocardiography permits the calculation of left ventricular (LV) ejection force (according to Newton's second law of motion). The ejection force was calculated in 36 patients with heart failure subgrouped into 3 groups based on ejection fraction (EF) (> 60%; 41-60%; < 40%) compared to 11 normal subjects. The LV ejection force showed a good linear correlation with LV ejection fraction (r = 0.86). Data of the study suggest that the LV ejection force is a valuable and accurate index for the assessment of cardiac performance, especially in early stages of disease.

  16. Miniature Laser Doppler Velocimeter for Measuring Wall Shear

    NASA Technical Reports Server (NTRS)

    Gharib, Morteza; Modarress, Darius; Forouhar, Siamak; Fourguette, Dominique; Taugwalder, Federic; Wilson, Daniel

    2005-01-01

    A miniature optoelectronic instrument has been invented as a nonintrusive means of measuring a velocity gradient proportional to a shear stress in a flow near a wall. The instrument, which can be mounted flush with the wall, is a variant of a basic laser Doppler velocimeter. The laser Doppler probe volume can be located close enough to the wall (as little as 100 micron from the surface) to lie within the viscosity-dominated sublayer of a turbulent boundary layer. The instrument includes a diode laser, the output of which is shaped by a diffractive optical element (DOE) into two beams that have elliptical cross sections with very high aspect ratios.

  17. Imaging doppler lidar for wind turbine wake profiling

    DOEpatents

    Bossert, David J.

    2015-11-19

    An imaging Doppler lidar (IDL) enables the measurement of the velocity distribution of a large volume, in parallel, and at high spatial resolution in the wake of a wind turbine. Because the IDL is non-scanning, it can be orders of magnitude faster than conventional coherent lidar approaches. Scattering can be obtained from naturally occurring aerosol particles. Furthermore, the wind velocity can be measured directly from Doppler shifts of the laser light, so the measurement can be accomplished at large standoff and at wide fields-of-view.

  18. Single pass Doppler positioning for Search and Rescue satellite missions

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.; Vonbun, F. O.; Lynn, J. J.

    1976-01-01

    This paper describes the implementation of beacon location experiments involving the NASA Nimbus-6 and the Amateur Satellite Corporation (AMSAT) Oscar-6 and Oscar-7 spacecraft. The purpose of these experiments is to demonstrate the feasibility of determining the geographical location of a low power VHF 'distress beacon' via satellite. Doppler data collected during satellite passes is reduced in a mini-computer by means of a simple algorithm resulting in the simultaneous recovery of the unknown receiver coordinates and the unknown Doppler bias frequency. Results indicate point positioning to within a few kilometers - which is within the required accuracies for the positioning of downed aircraft for Search/Rescue missions.

  19. Grayscale and Color Doppler Features of Testicular Lymphoma

    PubMed Central

    Bertolotto, Michele; Derchi, Lorenzo E.; Secil, Mustafa; Dogra, Vikram; Sidhu, Paul S.; Clements, Richard; Freeman, Simon; Grenier, Nicolas; Mannelli, Lorenzo; Ramchandani, Parvati; Cicero, Calogero; Abete, Luca; Bussani, Rossana; Rocher, Laurence; Spencer, John; Tsili, Athina; Valentino, Massimo; Pavlica, Pietro

    2016-01-01

    Pooled data from 16 radiology centers were retrospectively analyzed to seek patients with pathologically proven testicular lymphoma and grayscale and color Doppler images available for review. Forty-three cases were found: 36 (84%) primary and 7 (16%) secondary testicular lymphoma. With unilateral primary lymphoma, involvement was unifocal (n = 10), multifocal (n = 11), or diffuse (n = 11). Synchronous bilateral involvement occurred in 6 patients. Color Doppler sonography showed normal testicular vessels within the tumor in 31 of 43 lymphomas (72%). Testicular lymphoma infiltrates through the tubules, preserving the normal vascular architecture of the testis. Depiction of normal testicular vessels crossing the lesion is a useful adjunctive diagnostic criterion. PMID:26014335

  20. Doppler shifted H Ly alpha emission from Jupiter's aurora

    NASA Technical Reports Server (NTRS)

    Clarke, John T.; Trauger, John; Waite, J. Hunter, Jr.

    1989-01-01

    High-spectral-resolution IUE observations of the aurora on Jupiter were obtained in order to search for Doppler shifted H-Ly-alpha emission produced through charge exchange by fast precipitating protons. Although no emission has been observed corresponding to proton energies greater than 200 eV, a large fraction of the H-Ly-alpha emission has appeared Doppler shifted, mainly toward the blue, by about 50 km/s. These results show that the acceleration of ionospheric plasma in an H2 atmosphere can lead to bright Ly-alpha emission, setting constraints on the production of the outer planet airglow emissions.

  1. Single pass Doppler positioning for Search and Rescue satellite missions

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.; Vonbun, F. O.; Lynn, J. J.

    1976-01-01

    This paper describes the implementation of beacon location experiments involving the NASA Nimbus-6 and the Amateur Satellite Corporation (AMSAT) Oscar-6 and Oscar-7 spacecraft. The purpose of these experiments is to demonstrate the feasibility of determining the geographical location of a low power VHF 'distress beacon' via satellite. Doppler data collected during satellite passes is reduced in a mini-computer by means of a simple algorithm resulting in the simultaneous recovery of the unknown receiver coordinates and the unknown Doppler bias frequency. Results indicate point positioning to within a few kilometers - which is within the required accuracies for the positioning of downed aircraft for Search/Rescue missions.

  2. Power Doppler ultrasound appearances of neonatal ischaemic brain injury.

    PubMed

    Steventon, D M; John, P R

    1997-02-01

    Following neonatal ischaemic brain injury, irregular vessels increase in size owing to luxury perfusion. These may be demonstrated by conventional colour flow Doppler (CFD) imaging at the periphery of the infarcted area. We present a case in which power Doppler imaging (PDI) was performed in addition to CFD in a neonate with unexplained seizures and which proved more sensitive than CFD in demonstrating luxury perfusion. Ultrasound appearances were compared with those seen on cranial CT. PDI can be a useful adjunct to conventional CFD examination of the neonatal brain in cerebral infarction.

  3. Accommodations assessment: Spaceborne Doppler lidar wind measuring system

    NASA Technical Reports Server (NTRS)

    1981-01-01

    An accommodations analysis performed by the MSFC Preliminary Design Office for a spaceborne Doppler lidar wind measuring system is summarized. A dedicated, free-flying spacecraft design concept is described. Mass and beginning-of-life power requirements are estimated at 2260 kg and 6.0 - 8.5 kW respectively, to support a pulsed, CO2, Doppler lidar having a pulse energy of 10 J, pulse rate of 8 Hz, and efficiency of approximately 5%. Under the assumptions of the analysis, such a system would provide wind measurements on a global scale, with accuracies of a few meters per second.

  4. Color Doppler imaging of cardiac catheters using vibrating motors.

    PubMed

    Reddy, Kalyan E; Light, Edward D; Rivera, Danny J; Kisslo, Joseph A; Smith, Stephen W

    2008-10-01

    A miniature motor rotating at 11,000 rpm was attached onto the proximal end of cardiac electrophysiological (EP) catheters in order to produce vibrations at the tip that were then visualized by color Doppler on ultrasound scanners. The catheter tip was imaged within a vascular graft submerged in a water tank using the Volumetrics Medical Imaging 3D scanner, the Siemens Sonoline Antares 2D scanner and the Philips ie33 3D ultrasound scanner with TEE probe. The vibrating catheter tip was visualized in each case, although results varied with the color Doppler properties of the individual scanner.

  5. Quantum interference of biphotons with a Doppler frequency shift

    NASA Astrophysics Data System (ADS)

    Lariontsev, E. G.

    2016-08-01

    We report a theoretical study of transformation of a biphoton state of light under Bragg diffraction on a travelling sound wave in an acousto-optic modulator (AOM). It is shown that the diffraction of AOM biphotons emitted during the collinear parametric scattering of light leads to a shift of the carrier frequency of a biphoton wave packet, which exceeds twice the Doppler frequency shift for the classical field. A method is proposed for measuring the Doppler frequency shift of a biphoton, which is based on interference between independent biphotons.

  6. Method and apparatus for Doppler frequency modulation of radiation

    NASA Technical Reports Server (NTRS)

    Margolis, J. S.; Mccleese, D. J.; Shumate, M. S.; Seaman, C. H. (Inventor)

    1980-01-01

    A method and apparatus are described for frequency modulating radiation, such as from a laser, for optoacoustic detectors, interferometers, heterodyne spectrometers, and similar devices. Two oppositely reciprocating cats-eye retroreflectors are used to Doppler modulate the radiation. By reciprocally moving both retroreflectors, the center of mass is maintained constant to permit smooth operation at many Hertz. By slightly offsetting the axis of one retroreflector relative to the other, multiple passes of a light beam may be achieved for greater Doppler shifts with the same reciprocating motion of the retroreflectors.

  7. Barker code pulse compression with a large Doppler tolerance

    NASA Astrophysics Data System (ADS)

    Jiang, Xuefeng; Zhu, Zhaoda

    1991-03-01

    This paper discusses the application of least square approximate inverse filtering techniques to radar range sidelobe suppression. The method is illustrated by application to the design of a compensated noncoherent sidelobe suppression filter (SSF). The compensated noncoherent SSF of the 13-element Barker code has been found. The -40 kHz to 40 kHz Doppler tolerance of the filter is obtained under the conditions that the subpulse duration is equal to 0.7 microsec and the peak sidelobe level is less than -30 dB. Theoretical computations and experimental results indicate that the SSF implemented has much wider Doppler tolerance than the Rihaczek-Golden (1971) SSF.

  8. Aerial ultrasonic micro Doppler sonar detection range in outdoor environments.

    PubMed

    Bradley, Marshall; Sabatier, James M

    2012-03-01

    Current research demonstrates that micro Doppler sonar has the capability to uniquely identify the presence of a moving human, making it an attractive component in surveillance systems for border security applications. Primary environmental factors that limit sonar performance are two-way spreading losses, ultrasonic absorption, and backscattered energy from the ground that appears at zero Doppler shift in the sonar signal processor. Spectral leakage from the backscatter component has a significant effect on sonar performance for slow moving targets. Sonar performance is shown to rapidly decay as the sensor is moved closer to the ground due to increasing surface backscatter levels.

  9. Color Doppler Imaging of Cardiac Catheters Using Vibrating Motors

    PubMed Central

    Reddy, Kalyan E.; Light, Edward D.; Rivera, Danny J.; Kisslo, Joseph A.; Smith, Stephen W.

    2010-01-01

    We attached a miniature motor rotating at 11,000 rpm onto the proximal end of cardiac electrophysiological (EP) catheters in order to produce vibrations at the tip which were then visualized by color Doppler on ultrasound scanners. We imaged the catheter tip within a vascular graft submerged in a water tank using the Volumetrics Medical Imaging 3D scanner, the Siemens Sonoline Antares 2D scanner, and the Philips ie33 3D ultrasound scanner with TEE probe. The vibrating catheter tip was visualized in each case though results varied with the color Doppler properties of the individual scanner. PMID:19514134

  10. [Echocardiographic and Doppler echocardiographic characterization of left ventricular diastolic function].

    PubMed

    Muscholl, M; Dennig, K; Kraus, F; Rudolph, W

    1990-12-01

    For noninvasive assessment of diastolic ventricular function, in addition to echocardiography, more recently, in particular, Doppler echocardiography has been employed. M-mode echocardiogram velocity curves for diameter changes as well as Doppler-echocardiographically registered velocity curves of mitral flow characterize the temporal changes of diastolic flow into the left ventricle. They represent the overall result of factors which influence diastolic filling and are functions of the temporal course of the pressure difference between left atrium and left ventricle. Registration of M-mode and Doppler echocardiograms: For determination of M-mode parameters which should describe left ventricular diastolic function, in addition to the motion of the mitral valve, the left ventricular contours of septum and posterior wall between mitral leaflets and papillary muscles are recorded together with the ECG. For evaluation of the index of atrial emptying, an M-mode registration is obtained from the region of the aortic root. Determination of the Doppler echocardiographic parameters is based on analysis of the blood flow velocity in the region of the mitral valve in the apical four-chamber view with the pulsed Doppler method. Additionally, simultaneous to the Doppler curve, a phonocardiogram is registered or, alternatively, a continuous-wave Doppler registration is obtained which delineates the left ventricular outflow signal and the artefact of mitral valve opening. Parameters for characterization of left ventricular diastolic filling: The first peak of the velocity curve of the diameter change in the M-mode echocardiogram corresponds with the maximal diameter change resulting from early-diastolic filling and the second peak with the maximal diameter change of the left ventricle associated with atrial filling. From this curve as well as the diameter curve relative to time and the mitral valve motion, the times for isovolumetric relaxation as well as the rapid, slow and

  11. Multigroup Free-atom Doppler-broadening Approximation. Theory

    SciTech Connect

    Gray, Mark Girard

    2015-11-06

    Multigroup cross sections at a one target temperature can be Doppler-broadened to multigroup cross sections at a higher target temperature by matrix multiplication if the group structure suf- ficiently resolves the original temperature continuous energy cross section. Matrix elements are the higher temperature group weighted averages of the integral over the lower temperature group boundaries of the free-atom Doppler-broadening kernel. The results match theory for constant and 1/v multigroup cross sections at 618 lanl group structure resolution.

  12. C IV Doppler shifts observed in active region filaments

    NASA Technical Reports Server (NTRS)

    Klimchuk, J. A.

    1986-01-01

    The Doppler shift properties of 21 active region filaments were studied using C IV Dopplergram data. Most are associated with corridors of weak magnetic field that separate opposite polarity strong fields seen in photospheric magnetograms. A majority of the filaments are relatively blue shifted, although several lie very close to the dividing lines between blue and red shift. Only one filament in the samples is clearly red shifted. A new calibration procedure for Dopplergrams indicates that sizable zero point offsets are often required. The center-to-limb behavior of the resulting absolute Doppler shifts suggests that filament flows are usually quite small. It is possible that they vanish.

  13. Stretched-exponential Doppler spectra in underwater acoustic communication channels.

    PubMed

    van Walree, P A; Jenserud, T; Otnes, R

    2010-11-01

    The theory of underwater sound interacting with the sea surface predicts a Gaussian-spread frequency spectrum in the case of a large Rayleigh parameter. However, recent channel soundings reveal more sharply peaked spectra with heavier tails. The measured Doppler spread increases with the frequency and differs between multipath arrivals. The overall Doppler spectrum of a broadband waveform is the sum of the spectra of all constituent paths and frequencies, and is phenomenologically described by a stretched or compressed exponential. The stretched exponential also fits well to the broadband spectrum of a single propagation path, and narrowband spectra summed over all paths.

  14. Fetal and umbilical Doppler ultrasound in normal pregnancy.

    PubMed

    Alfirevic, Zarko; Stampalija, Tamara; Medley, Nancy

    2015-04-15

    One of the main aims of routine antenatal care is to identify the 'at risk' fetus in order to apply clinical interventions which could result in reduced perinatal morbidity and mortality. Doppler ultrasound study of umbilical artery waveforms helps to identify the compromised fetus in 'high-risk' pregnancies and, therefore, deserves assessment as a screening test in 'low-risk' pregnancies. To assess the effects on obstetric practice and pregnancy outcome of routine fetal and umbilical Doppler ultrasound in unselected and low-risk pregnancies. We searched the Cochrane Pregnancy and Childbirth Group Trials Register (28 February 2015) and reference lists of retrieved studies. Randomised and quasi-randomised controlled trials of Doppler ultrasound for the investigation of umbilical and fetal vessels waveforms in unselected pregnancies compared with no Doppler ultrasound. Studies where uterine vessels have been assessed together with fetal and umbilical vessels have been included. Two review authors independently assessed the studies for inclusion, assessed risk of bias and carried out data extraction. In addition to standard meta-analysis, the two primary outcomes and five of the secondary outcomes were assessed using GRADE software and methodology. We included five trials that recruited 14,624 women, with data analysed for 14,185 women. All trials had adequate allocation concealment, but none had adequate blinding of participants, staff or outcome assessors. Overall and apart from lack of blinding, the risk of bias for the included trials was considered to be low.Overall, routine fetal and umbilical Doppler ultrasound examination in low-risk or unselected populations did not result in increased antenatal, obstetric and neonatal interventions. There were no group differences noted for the review's primary outcomes of perinatal death and neonatal morbidity. Results for perinatal death were as follows: (average risk ratio (RR) 0.80, 95% confidence interval (CI) 0.35 to 1

  15. Doppler and range determination for deep space vehicles using active optical transponders

    NASA Technical Reports Server (NTRS)

    Kinman, Peter W.; Gagliardi, Robert M.

    1988-01-01

    This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.

  16. Doppler velocimetric parameters of the testicular artery in healthy dogs.

    PubMed

    de Souza, Mírley Barbosa; da Cunha Barbosa, Claudia; Pereira, Barbara Sucupira; Monteiro, Cynthia Levi Baratta; Pinto, José Nicodemos; Linhares, Jussiara Candeira Spíndola; da Silva, Lúcia Daniel Machado

    2014-06-01

    This study aimed to examine the Doppler velocimetric pattern of the testicular artery of small dogs in two different locations. Testes of 21 dogs were evaluated by two-dimensional ultrasonography to measure testicular volume and by Doppler ultrasonography to record the velocimetric patterns of the testicular artery in the spermatic cord and marginal location. The volume of left testes (4.70 ± 1.22 cm(3)) was significantly higher than the volume of the right testes (4.45 ± 1.17 cm(3)). Peak systolic velocity (PSV) of the left spermatic cord was significantly higher than the right side. End-diastolic velocity was significantly higher in the marginal artery than the spermatic cord on both sides; however, resistance and pulsatility indexes were significantly lower in the marginal artery. Results demonstrate the viability of Doppler ultrasonography for characterization of the testicular artery in small dogs and Doppler velocimetric values vary according to the location of measurement along the artery.

  17. Low Cost Coherent Doppler Lidar Data Acquisition and Processing

    NASA Technical Reports Server (NTRS)

    Barnes, Bruce W.; Koch, Grady J.

    2003-01-01

    The work described in this paper details the development of a low-cost, short-development time data acquisition and processing system for a coherent Doppler lidar. This was done using common laboratory equipment and a small software investment. This system provides near real-time wind profile measurements. Coding flexibility created a very useful test bed for new techniques.

  18. Airborne Wind Profiling Algorithm for Doppler Wind LIDAR

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable airborne Doppler Wind LIDAR system measurements and INS/GPS measurements to be combined to estimate wind parameters and compensate for instrument misalignment. In a further embodiment, the wind speed and wind direction may be computed based on two orthogonal line-of-sight LIDAR returns.

  19. Multi-sensor Doppler radar for machine tool collision detection

    NASA Astrophysics Data System (ADS)

    Wächter, T. J.; Siart, U.; Eibert, T. F.; Bonerz, S.

    2014-11-01

    Machine damage due to tool collisions is a widespread issue in milling production. These collisions are typically caused by human errors. A solution for this problem is proposed based on a low-complexity 24 GHz continuous wave (CW) radar system. The developed monitoring system is able to detect moving objects by evaluating the Doppler shift. It combines incoherent information from several spatially distributed Doppler sensors and estimates the distance between an object and the sensors. The specially designed compact prototype contains up to five radar sensor modules and amplifiers yet fits into the limited available space. In this first approach we concentrate on the Doppler-based positioning of a single moving target. The recorded signals are preprocessed in order to remove noise and interference from the machinery hall. We conducted and processed system measurements with this prototype. The Doppler frequency estimation and the object position obtained after signal conditioning and processing with the developed algorithm were in good agreement with the reference coordinates provided by the machine's control unit.

  20. Results of the observations with Doppler receiver DOG-2.

    NASA Astrophysics Data System (ADS)

    Fraczyk, P.; Jakś, W.

    In this paper a general description of the operation of the Doppler receiver DOG-2, produced in Poland, is presented as well as the actual results of determination of the Borowiec geocentric coordinates obtained from observations made by the use of that receiver. Processing of data was performed with the program GEODOP.

  1. Results of the observations with Doppler receiver DOG-2

    NASA Astrophysics Data System (ADS)

    Fraczyk, P.; Jaks, W.

    The operation of a Doppler receiver, DOG-2, produced in Poland, as well as the instrumental equipment and computing facilities, are described. Results of the determination of Borowiec geocentric coordinates, obtained from observations made by the receiver, are presented. Data processing is performed by means of the GEODOP program. The observational results for the receivers prove their usefulness in geodetic-astronomical investigations.

  2. Dual beam translator for use in Laser Doppler anemometry

    DOEpatents

    Brudnoy, D.M.

    1984-04-12

    A method and apparatus for selectively translating the path of at least one pair of light beams in a Laser Doppler anemometry device whereby the light paths are translated in a direction parallel to the original beam paths so as to enable attainment of spacial coincidence of the two intersection volumes and permit accurate measurements of Reynolds shear stress.

  3. Christian Andreas Doppler--the man and his legacy.

    PubMed

    Coman, I M

    2005-01-01

    Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.

  4. Doppler optical mixing spectroscopy in multiparticle scattering fluids

    SciTech Connect

    Dubnishchev, Yu N

    2011-03-31

    We discuss the basic scheme of laser Doppler optical mixing spectroscopy for the analysis of media with multiparticle scattering. It is shown that the Rayleigh scheme, in contrast to the heterodyne and differential schemes, is insensitive to the effects of multiparticle scattering. (laser applications and other aspects of quantum electronics)

  5. A range-rate extraction unit for determining Doppler effect

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Active ranging technique devised for VHF or S-band radar systems divides target Doppler frequency by counter-generated number that is proportional to transmitting frequency, thus producing target velocity data in terms of speed and distance relative to target transponder.

  6. Research on Fast-Doppler-Broadening of neutron cross sections

    SciTech Connect

    Li, S.; Wang, K.; Yu, G.

    2012-07-01

    A Fast-Doppler-Broadening method is developed in this work to broaden Continuous Energy neutron cross-sections for Monte Carlo calculations. Gauss integration algorithm and parallel computing are implemented in this method, which is unprecedented in the history of cross section processing. Compared to the traditional code (NJOY, SIGMA1, etc.), the new Fast-Doppler-Broadening method shows a remarkable speedup with keeping accuracy. The purpose of using Gauss integration is to avoid complex derivation of traditional broadening formula and heavy load of computing complementary error function that slows down the Doppler broadening process. The OpenMP environment is utilized in parallel computing which can take full advantage of modern multi-processor computers. Combination of the two can reduce processing time of main actinides (such as {sup 238}U, {sup 235}U) to an order of magnitude of 1{approx}2 seconds. This new method is fast enough to be applied to Online Doppler broadening. It can be combined or coupled with Monte Carlo transport code to solve temperature dependent problems and neutronics-thermal hydraulics coupled scheme which is a big challenge for the conventional NJOY-MCNP system. Examples are shown to determine the efficiency and relative errors compared with the NJOY results. A Godiva Benchmark is also used in order to test the ACE libraries produced by the new method. (authors)

  7. Robust estimation of fetal heart rate from US Doppler signals

    NASA Astrophysics Data System (ADS)

    Voicu, Iulian; Girault, Jean-Marc; Roussel, Catherine; Decock, Aliette; Kouame, Denis

    2010-01-01

    Introduction: In utero, Monitoring of fetal wellbeing or suffering is today an open challenge, due to the high number of clinical parameters to be considered. An automatic monitoring of fetal activity, dedicated for quantifying fetal wellbeing, becomes necessary. For this purpose and in a view to supply an alternative for the Manning test, we used an ultrasound multitransducer multigate Doppler system. One important issue (and first step in our investigation) is the accurate estimation of fetal heart rate (FHR). An estimation of the FHR is obtained by evaluating the autocorrelation function of the Doppler signals for ills and healthiness foetus. However, this estimator is not enough robust since about 20% of FHR are not detected in comparison to a reference system. These non detections are principally due to the fact that the Doppler signal generated by the fetal moving is strongly disturbed by the presence of others several Doppler sources (mother' s moving, pseudo breathing, etc.). By modifying the existing method (autocorrelation method) and by proposing new time and frequency estimators used in the audio' s domain, we reduce to 5% the probability of non-detection of the fetal heart rate. These results are really encouraging and they enable us to plan the use of automatic classification techniques in order to discriminate between healthy and in suffering foetus.

  8. Spectrum of Doppler ultrasound signals from nonstationary blood flow.

    PubMed

    Bastos, C C; Fish, P J; Vaz, F

    1999-01-01

    A new formulation for the Doppler signal generation process in pulsatile flow has been developed enabling easier identification and quantification of the mechanisms involved in spectral broadening and the development of a simple estimation formula for the measured rms spectral width. The accuracy of the estimation formula was tested by comparing it with the spectral widths found by using conventional spectral estimation on simulated Doppler signals from pulsatile flow. The influence of acceleration, sample volume size, and time window duration on the Doppler spectral width was investigated for flow with blunt and parabolic velocity profiles passing through Gaussian-shaped sample volumes. Our results show that, for short duration windows, the spectral width is dominated by window broadening and that acceleration has a small effect on the spectral width. For long duration windows, the effect of acceleration must be taken into account. The size of the sample volume affects the spectral width of the Doppler signal in two ways: by intrinsic broadening and by the range of velocities passing through it. These effects act in opposite directions. The simple spectral width estimation formula was shown to have excellent agreement with widths calculated using the model and indicates the potential for correcting not only for window and nonstationarity broadening but also for intrinsic broadening.

  9. Validar: a testbed for advanced 2-micron Doppler lidar

    NASA Astrophysics Data System (ADS)

    Koch, Grady J.; Petros, Mulugeta; Barnes, Bruce W.; Beyon, Jeffrey Y.; Amzajerdian, Farzin; Yu, Jirong; Kavaya, Michael J.; Singh, Upendra N.

    2004-09-01

    High-energy 2-micron lasers have been incorporated in a breadboard coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Sample data is presented on wind profiling and CO2 concentration measurements.

  10. Pediatric imaging/doppler ultrasound of the chest: Extracardiac diagnosis

    SciTech Connect

    Huhta, J.C.

    1986-01-01

    In this book the author spells out new diagnostic applications in pediatrics for high resolution cross-sectional ultrasonography, and demonstrates the ways in which Doppler techniques complement the cross-sectional method. This reference presents practical, step-by-step methods for non-invasive ultrasound examination of extra-cardiac anatomy and assessment of vascular blood flow.

  11. Method and system of doppler correction for mobile communications systems

    NASA Technical Reports Server (NTRS)

    Georghiades, Costas N. (Inventor); Spasojevic, Predrag (Inventor)

    1999-01-01

    Doppler correction system and method comprising receiving a Doppler effected signal comprising a preamble signal (32). A delayed preamble signal (48) may be generated based on the preamble signal (32). The preamble signal (32) may be multiplied by the delayed preamble signal (48) to generate an in-phase preamble signal (60). The in-phase preamble signal (60) may be filtered to generate a substantially constant in-phase preamble signal (62). A plurality of samples of the substantially constant in-phase preamble signal (62) may be accumulated. A phase-shifted signal (76) may also be generated based on the preamble signal (32). The phase-shifted signal (76) may be multiplied by the delayed preamble signal (48) to generate an out-of-phase preamble signal (80). The out-of-phase preamble signal (80) may be filtered to generate a substantially constant out-of-phase preamble signal (82). A plurality of samples of the substantially constant out-of-phase signal (82) may be accumulated. A sum of the in-phase preamble samples and a sum of the out-of-phase preamble samples may be normalized relative to each other to generate an in-phase Doppler estimator (92) and an out-of-phase Doppler estimator (94).

  12. Determining the Speed of Sound Using the Doppler Effect.

    ERIC Educational Resources Information Center

    Gagne, Richard.

    1996-01-01

    Presents a simple but effective experiment that uses ultrasonic transducers and some basic electronics to study the speed of sound using the Doppler effect. Eliminates the noise problems associated with most sound experiments. Discusses the theory, and describes the apparatus and procedure. (JRH)

  13. Wing tip vortex measurements with laser Doppler systems

    NASA Technical Reports Server (NTRS)

    Fuller, C. E., III

    1973-01-01

    The vortex velocity field produced by a rectangular wing in a subsonic wind tunnel was measured using two laser Doppler velocimeter systems. One system made three dimensional mean velocity measurements and the other made one dimensional turbulence measurements. The systems and test procedures are described and comparisons of the measurements are made. The data defined a strong spiral motion in the vortex formation process.

  14. Multiplexed sub-Doppler spectroscopy with an optical frequency comb

    NASA Astrophysics Data System (ADS)

    Long, D. A.; Fleisher, A. J.; Plusquellic, D. F.; Hodges, J. T.

    2016-12-01

    An optical frequency comb generated with an electro-optic phase modulator and a chirped radio-frequency waveform is used to perform pump-probe spectroscopy on the D1 and D2 transitions of atomic potassium at 770.1 and 766.7 nm, respectively. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be observed simultaneously. Interferograms are recorded in as little as 5 µs (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.

  15. Microcomputer-based doppler systems for weather monitoring

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.; Lynn, J. J.

    1980-01-01

    Ground-based microcomputer determines geographical positions of beacons using Doppler data from weather satellites. System requires onnly 7 W and incorporates least-squares iteration to compute positions. Results are printed out in alphanumerics either on CRT or on teletype. 6502 CPU was used, although equivalent processor could be substituted (with appropriate modifications to hardware).

  16. Anomaly Detection In Additively Manufactured Parts Using Laser Doppler Vibrometery

    SciTech Connect

    Hernandez, Carlos A.

    2015-09-29

    Additively manufactured parts are susceptible to non-uniform structure caused by the unique manufacturing process. This can lead to structural weakness or catastrophic failure. Using laser Doppler vibrometry and frequency response analysis, non-contact detection of anomalies in additively manufactured parts may be possible. Preliminary tests show promise for small scale detection, but more future work is necessary.

  17. [Kidney obstruction: potential use of ultrasonography and Doppler color ultrasonography].

    PubMed

    Bertolotto, M; Perrone, R; Rimondini, A

    2000-12-01

    Ultrasonography is the first imaging approach in evaluation of patients with urinary obstruction. Presence of hydronephrosis, urinomas and inflammatory complications can be assessed. Moreover, the level and the cause of obstruction are often identified. The major limits of ultrasonography are poor visibility of the lumbar portion of the urinary tract and lack of specificity in detection of pyelocaliectasis. These limits are partially overcome with Doppler studies. Several factors can bias diagnostic accuracy of colour Doppler ultrasonography in evaluating renal obstruction; in particular, partial or intermittent obstruction cause minimum hemodynamic changes in patients with renal colic. Sensitivity of colour Doppler ultrasonography to detect obstruction decreases following medical treatment with NSAID and increases following hydration and diuretics administration. Diuretic ultrasound, colour Doppler evaluation of ureteral jets and evaluation of the twinkling artefact of stones are useful imaging techniques as well. Tissue harmonic imaging is a new imaging technique available in most latest generation US equipments. Evaluation of the kidney and of the urinary tract improves using this technique due to artefact reduction and increased contrast resolution.

  18. Language Lateralization in Children Using Functional Transcranial Doppler Sonography

    ERIC Educational Resources Information Center

    Haag, Anja; Moeller, Nicola; Knake, Susanne; Hermsen, Anke; Oertel, Wolfgang H.; Rosenow, Felix; Hamer, Hajo M.

    2010-01-01

    Aim: Language lateralization with functional transcranial Doppler sonography (fTCD) and lexical word generation has been shown to have high concordance with the Wada test and functional magnetic resonance imaging in adults. We evaluated a nonlexical paradigm to determine language dominance in children. Method: In 23 right-handed children (12…

  19. Language Lateralization in Children Using Functional Transcranial Doppler Sonography

    ERIC Educational Resources Information Center

    Haag, Anja; Moeller, Nicola; Knake, Susanne; Hermsen, Anke; Oertel, Wolfgang H.; Rosenow, Felix; Hamer, Hajo M.

    2010-01-01

    Aim: Language lateralization with functional transcranial Doppler sonography (fTCD) and lexical word generation has been shown to have high concordance with the Wada test and functional magnetic resonance imaging in adults. We evaluated a nonlexical paradigm to determine language dominance in children. Method: In 23 right-handed children (12…

  20. Doppler Lidar in the Wind Forecast Improvement Projects

    NASA Astrophysics Data System (ADS)

    Pichugina, Yelena; Banta, Robert; Brewer, Alan; Choukulkar, Aditya; Marquis, Melinda; Olson, Joe; Hardesty, Mike

    2016-06-01

    This paper will provide an overview of some projects in support of Wind Energy development involving Doppler lidar measurement of wind flow profiles. The high temporal and vertical resolution of these profiles allows the uncertainty of Numerical Weather Prediction models to be evaluated in forecasting dynamic processes and wind flow phenomena in the layer of rotor-blade operation.

  1. High-Energy 2-Micrometers Doppler Lidar for Wind Measurements

    NASA Technical Reports Server (NTRS)

    Koch, Grady J.; Beyon, Jeffrey Y.; Barnes, Bruce W.; Petros, Mulugeta; Yu, Jirong; Amzajerdian, Farzin; Kavaya, Michael J.; Singh, Upendra N.

    2006-01-01

    High-energy 2-micrometer wavelength lasers have been incorporated in a prototype coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Calibration tests and sample atmospheric data are presented on wind and aerosol profiling.

  2. Clinical evaluation of a diameter sensing Doppler cardiac output meter.

    PubMed

    Niclou, R; Teague, S M; Lee, R

    1990-04-01

    A concentric beam Doppler ultrasonic flowmeter has been developed. This instrument has capacity for independent assessment of volumetric flow, as it determines flow cross-section area, stroke length, and pulse rate from the Doppler signals alone. The method is practically independent of the angle of interrogation. We used this device and obtained noninvasive estimates of cardiac output in 54 patients undergoing invasive assessment of cardiac output by thermodilution, Fick, or indicator dye methods (x). Correlations against pooled cardiac output reference standards ranged from r = .86 (y = .86x + 1.03) in 26 studies of high confidence to r = .45 (y = .30x + 2.62) in 17 studies under difficult conditions. The overall correlation was r = .68 (y = .63x + 1.49, n = 87). Noninvasive results of experienced and inexperienced operators were similar (r = .87). The instrument returned accurate assessments of heart rate (r = .83), but underestimated stroke length (r = .72) and appeared to be limited in the assessment of aortic diameters less than 28 or greater than 31 mm (r = .23). We conclude that stand-alone Doppler assessment of cardiac output is appealing and feasible, but difficult or impossible in many ICU scenarios. Further evolution of the concentric beam Doppler approach is needed and anticipated.

  3. [Myocardial function analysis with echocardiography-Doppler in septic shock].

    PubMed

    Fayssoil, A; Checinski, A

    2012-02-01

    Septic shock is a severe sepsis associated with cardio-circulatory failure and tissular hypoperfusion. Echocardiography-Doppler remains essential for the assessment of myocardial function in septic shock. This ultrasound procedure helps clinicians for the analysis of left ventricular systolic function, left ventricular diastolic function, right ventricular function and cardiac filling.

  4. Doppler shifts of radar return from the sea surface

    NASA Astrophysics Data System (ADS)

    Ermakov, S. A.; Kapustin, I. A.; Molkov, A. A.; Sergievskaya, I. A.; Shomina, O. V.

    2016-10-01

    Investigation of the Doppler shift of radar return from the sea surface is very important for better understanding of capabilities of exploitation of microwave radar for measuring velocities of marine currents. Here new field experiments carried out from a Platform on the Black Sea with a coherent X-band scatterometer, and a Doppler multifrequency (X- /C-/S-band) dual-polarized radar recently designed at IAP RAS are discussed. It is shown that the radar return contains both Bragg (polarized) and non polarized scattering components, presumably giving different contributions to radar Doppler shifts. Radar Doppler shifts were estimated using two different definitions as a) a frequency of the "centre of gravity" of an instantaneous radar return spectrum (ASIS) averaged over periods of dominant wind waves and b) the "centre of gravity" of the averaged over dominant wave periods spectrum (SAS). The ASIS and SAS values for both VV and HH-polarizations are shown to be different due to effects of radar backscatter modulation by dominant (long) wind waves. The radar Modulation Transfer Function (MTF) has been analyzed from experimental data and difference between SAS- and ASIS-values has been satisfactory explained using the measured MTF-values. It is obtained that experimental values of ASIS can be satisfactory described by the Bragg model despite the significant contribution of NP component to the radar backscatter. A physical explanation of the effect is given.

  5. Analysis of multiple scattering effects in optical Doppler tomography

    NASA Astrophysics Data System (ADS)

    Yura, Harold T.; Thrane, Lars; Andersen, Peter E.

    2005-08-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed Doppler frequency spectrum. Thus, in the present analysis, the dependence of the mean and standard deviation of the Doppler shift on the scattering properties of the flowing medium are obtained. Taking the multiple scattering effects into account, we are able to explain previous measurements of depth-resolved retinal flow profiles where the influence of multiple scattering was observed [Yazdanfar et al., Opt. Lett. 25, 1448 (2000)]. To the best of our knowledge, no analytical model exists that are able to explain these observations.

  6. Analysis of multiple scattering effects in optical Doppler tomography

    NASA Astrophysics Data System (ADS)

    Yura, Harold T.; Thrane, Lars; Andersen, Peter E.

    2005-04-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed Doppler frequency spectrum. Thus, in the present analysis, the dependence of the mean and standard deviation of the Doppler shift on the scattering properties of the flowing medium are obtained. Taking the multiple scattering effects into account, we are able to explain previous measurements of depth-resolved retinal flow profiles where the influence of multiple scattering was observed [Yazdanfar et al., Opt. Lett. 25, 1448 (2000)]. To the best of our knowledge, no analytical model exists that are able to explain these observations.

  7. How to Study the Doppler Effect with Audacity Software

    ERIC Educational Resources Information Center

    Dias, Marco Adriano; Carvalho, Paulo Simeão; Ventura, Daniel Rodrigues

    2016-01-01

    The Doppler effect is one of the recurring themes in college and high school classes. In order to contextualize the topic and engage the students in their own learning process, we propose a simple and easily accessible activity, i.e. the analysis of the videos available on the internet by the students. The sound of the engine of the vehicle…

  8. Coincidence doppler broadening study in electron-irradiated polyurethane

    NASA Astrophysics Data System (ADS)

    Yang, D. J.; Zhang, J. D.; Leung, J. K. C.; Beling, C. D.; Liu, L. B.

    2007-06-01

    Coincidence doppler broadening measurements on electron-irradiated polyurethanes were performed in the presence of air. It is shown that, after a certain electron irradiation, the momentum density distributions of annihilation electrons have obvious changes for the high crosslinking polyurethane, but no significant changes have been observed for the low crosslinking polyurethane. The results were performed to analyse by irradiation crosslinking and degradation principles.

  9. Reliability of Doppler sonography in extracranial cerebro-vascular stenosis.

    PubMed

    Colon, E J; de Weerd, J P; Notermans, S L; Vingerhoets, H M

    1979-01-01

    Of our patients who underwent quantitative Doppler sonography (Haemato-Tacho-Graphy), 382 underwent carotid angiography and 61 vertebral artery angiography. The reliability of the method proved to be between 90 and 95 percent for carotid as well as for vertebral arteries. The HTG proved to be a useful addition to angiography in patients with extracranial cerebro-vascular stenosis.

  10. Asymmetric micro-Doppler frequency comb generation via magnetoelectric coupling

    NASA Astrophysics Data System (ADS)

    Filonov, Dmitry; Steinberg, Ben Z.; Ginzburg, Pavel

    2017-06-01

    Electromagnetic scattering from moving bodies, being an inherently time-dependent phenomenon, gives rise to a generation of new frequencies, which can be used to characterize the motion. Whereas an ordinary motion along a linear path produces a constant Doppler shift, an accelerated scatterer can generate a micro-Doppler frequency comb. The spectra produced by rotating objects were studied and observed in a bistatic lock-in detection scheme. The internal geometry of a scatterer was shown to determine the spectrum, and the degree of structural asymmetry was suggested to be identified via signatures in the micro-Doppler comb. In particular, hybrid magnetoelectric particles, showing an ultimate degree of asymmetry in forward and backward scattering directions, were investigated. It was shown that the comb in the backward direction has signatures at the fundamental rotation frequency and its odd harmonics, whereas the comb of the forward scattered field has a prevailing peak at the doubled frequency and its multiples. Additional features of the comb were shown to be affected by the dimensions of the particle and by the strength of the magnetoelectric coupling. Experimental verification was performed with a printed circuit board antenna based on a wire and a split ring, while the structure was illuminated at a 2 GHz carrier frequency. Detailed analysis of micro-Doppler combs enables remote detection of asymmetric features of distant objects and could find use in a span of applications, including stellar radiometry and radio identification.

  11. How to Study the Doppler Effect with Audacity Software

    ERIC Educational Resources Information Center

    Dias, Marco Adriano; Carvalho, Paulo Simeão; Ventura, Daniel Rodrigues

    2016-01-01

    The Doppler effect is one of the recurring themes in college and high school classes. In order to contextualize the topic and engage the students in their own learning process, we propose a simple and easily accessible activity, i.e. the analysis of the videos available on the internet by the students. The sound of the engine of the vehicle…

  12. Phase dynamics in a Doppler broadened optically-pumped laser

    NASA Astrophysics Data System (ADS)

    Roldán, E.; de Valcárcel, G. J.; Vilaseca, R.; Silva, F.; Pujol, J.; Corbalán, R.; Laguarta, F.

    1989-11-01

    The dynamic behavior of the phase of the generated field in a Doppler-broadened optically-pumped far-infrared laser is theoretically investigated for the first time. The phase undergoes sudden jumps of approximately π radians, which allow to establish the actual symmetry of the main attractor in the phase space, explaining the heteroclynic character of the chaotic behavior observed in experiments.

  13. Validar: A Testbed for Advanced 2-Micron Doppler Lidar

    NASA Technical Reports Server (NTRS)

    Koch, Grady J.; Petros, Mulugeta; Barnes, Bruce W.; Beyon, Jeffrey Y.; Amzajerdian, Farzin; Yu, Jirong; Kavaya, Michael J.; Singh, Upendra N.

    2004-01-01

    High-energy 2-microns lasers have been incorporated in a breadboard coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Sample data is presented on wind profiling and CO2 concentration measurements.

  14. Doppler ultrasound and renal artery stenosis: An overview.

    PubMed

    Granata, A; Fiorini, F; Andrulli, S; Logias, F; Gallieni, M; Romano, G; Sicurezza, E; Fiore, C E

    2009-12-01

    Renovascular disease is a complex disorder, most commonly caused by fibromuscular dysplasia and atherosclerotic diseases. It can be found in one of three forms: asymptomatic renal artery stenosis (RAS), renovascular hypertension, and ischemic nephropathy. Particularly, the atherosclerotic form is a progressive disease that may lead to gradual and silent loss of renal function. Thus, early diagnosis of RAS is an important clinical objective since interventional therapy may improve or cure hypertension and preserve renal function. Screening for RAS is indicated in suspected renovascular hypertension or ischemic nephropathy, in order to identify patients in whom an endoluminal or surgical revascularization is advisable. Screening tests for RAS have improved considerably over the last decade. While captopril renography was widely used in the past, Doppler ultrasound (US) of the renal arteries (RAs), angio-CT, or magnetic resonance angiography (MRA) have replaced other modalities and they are now considered the screening tests of choice. An arteriogram is rarely needed for diagnostic purposes only. Color-Doppler US (CDUS) is a noninvasive, repeatable, relatively inexpensive diagnostic procedure which can accurately screen for renovascular diseases if performed by an expert. Moreover, the evaluation of the resistive index (RI) at Doppler US may be very useful in RAS affected patients for predicting the response to revascularization. However, when a discrepancy exists between clinical data and the results of Doppler US, additional tests are mandatory.

  15. Study of an airborne Doppler radar: Project Asterix

    NASA Astrophysics Data System (ADS)

    Testud, Jacques; Baudin, F.; Amayenc, P.

    Specifications for an airborne Doppler radar for meteorological applications are given. The following areas are covered: (1) principle for measuring three-dimensional speed field; (2) pulse pattern and detectability; (3) antenna; (4) processing of data; (5) analog system; (6) data control and recording; (7) attitude control and vibrations; and (8) logistics.

  16. Noise Studies of Externally Dispersed Interferometry for Doppler Velocimetry

    SciTech Connect

    Erskine, D J; Edelstein, J; Lloyd, J; Muirhead, P

    2006-05-04

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. Both regular and high-frequency spectral components can be recovered from the data--the moire component carries additional information that increases the signal to noise for velocimetry and spectroscopy. Here we present simulations and theoretical studies of the photon limited Doppler velocity noise in an EDI. We used a model spectrum of a 1600K temperature star. For several rotational blurring velocities 0, 7.5, 15 and 25 km/s we calculated the dimensionless Doppler quality index (Q) versus wavenumber v. This is the normalized RMS of the derivative of the spectrum and is proportional to the photon-limited Doppler signal to noise ratio.

  17. Determining the Speed of Sound Using the Doppler Effect.

    ERIC Educational Resources Information Center

    Gagne, Richard.

    1996-01-01

    Presents a simple but effective experiment that uses ultrasonic transducers and some basic electronics to study the speed of sound using the Doppler effect. Eliminates the noise problems associated with most sound experiments. Discusses the theory, and describes the apparatus and procedure. (JRH)

  18. Study of coherent clutter model for airborne pulse-Doppler radar

    NASA Astrophysics Data System (ADS)

    Chen, Xingyu; Guan, Yifu

    2017-08-01

    This paper gives an efficient coherent clutter model for airborne pulse-Doppler radar in arbitrary posture. The ground is separated by range rings and angle units instead of range rings with Doppler units so as to reduce the computation cost. The MATLAB simulation gives the range-Doppler map of the clutter and the result proves the effectiveness of the clutter model.

  19. Analysis of Doppler Lidar Data Acquired During the Pentagon Shield Field Campaign

    DTIC Science & Technology

    2011-04-01

    two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the...Observations from two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to... coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the overall

  20. Utero-placental Doppler ultrasound for improving pregnancy outcome

    PubMed Central

    Stampalija, Tamara; Gyte, Gillian ML; Alfirevic, Zarko

    2014-01-01

    Background Impaired placentation can cause some of the most important obstetrical complications such as pre-eclampsia and intrauterine growth restriction and has been linked to increased fetal morbidity and mortality. The failure to undergo physiological trophoblastic vascular changes is reflected by the high impedance to the blood flow at the level of the uterine arteries. Doppler ultrasound study of utero-placental blood vessels, using waveform indices or notching, may help to identify the ‘at-risk’ women in the first and second trimester of pregnancy, such that interventions might be used to reduce maternal and fetal morbidity and/or mortality. Objectives To assess the effects on pregnancy outcome, and obstetric practice, of routine utero-placental Doppler ultrasound in first and second trimester of pregnancy in pregnant women at high and low risk of hypertensive complications. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (June 2010) and the reference lists of identified studies. Selection criteria Randomised and quasi-randomised controlled trials of Doppler ultrasound for the investigation of utero-placental vessel waveforms in first and second trimester compared with no Doppler ultrasound. We have excluded studies where uterine vessels have been assessed together with fetal and umbilical vessels. Data collection and analysis Two authors independently assessed the studies for inclusion, assessed risk of bias and carried out data extraction. We checked data entry. Main results We found two studies involving 4993 participants. The methodological quality of the trials was good. Both studies included women at low risk for hypertensive disorders, with Doppler ultrasound of the uterine arteries performed in the second trimester of pregnancy. In both studies, pathological finding of uterine arteries was followed by low-dose aspirin administration. We identified no difference in short-term maternal and fetal clinical

  1. Fetal and umbilical Doppler ultrasound in high-risk pregnancies

    PubMed Central

    Alfirevic, Zarko; Stampalija, Tamara; Gyte, Gillian ML

    2014-01-01

    Background Abnormal blood flow patterns in fetal circulation detected by Doppler ultrasound may indicate poor fetal prognosis. It is also possible false positive Doppler ultrasound findings could encourage inappropriate early delivery. Objectives The objective of this review was to assess the effects of Doppler ultrasound used to assess fetal well-being in high-risk pregnancies on obstetric care and fetal outcomes. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (September 2009) and the reference lists of identified studies. Selection criteria Randomised and quasi-randomised controlled trials of Doppler ultrasound for the investigation of umbilical and fetal vessels waveforms in high-risk pregnancies compared to no Doppler ultrasound. Data collection and analysis Two authors independently assessed the studies for inclusion, assessed risk of bias and carried out data extraction. Data entry was checked. Main results Eighteen completed studies involving just over 10,000 women were included. The trials were generally of unclear quality with some evidence of possible publication bias. The use of Doppler ultrasound in high-risk pregnancy was associated a reduction in perinatal deaths (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.52 to 0.98, 16 studies, 10,225 babies, 1.2% versus 1.7 %, numbers needed to treat = 203; 95%CI 103 to 4352). There were also fewer inductions of labour (average RR 0.89, 95% CI 0.80 to 0.99, 10 studies, 5633 women, random effects) and fewer caesarean sections (RR 0.90, 95% CI 0.84 to 0.97, 14 studies, 7918 women). No difference was found in operative vaginal births (RR 0.95, 95% CI 0.80 to 1.14, four studies, 2813 women) nor in Apgar scores less than seven at five minutes (RR 0.92, 95% CI 0.69 to 1.24, seven studies, 6321 babies). Authors’ conclusions Current evidence suggests that the use of Doppler ultrasound in high-risk pregnancies reduced the risk of perinatal deaths and resulted in less

  2. Doppler signatures of the atmospheric circulation on hot Jupiters

    NASA Astrophysics Data System (ADS)

    Showman, A. P.; Fortney, J. J.; Lewis, N. K.; Shabram, M.

    2011-10-01

    To date, the exotic meteorology of hot Jupiters has primarily been characterized with thermal measurements of secondary eclipse depths and phase curves, providing only indirect clues to the wind regime. Recently, however, Snellen et al. (2010) presented highresolution groundbased spectra of HD 209458b obtained during transit. From analysis of the data, they reported an overall 2±1 km/sec blueshift in 56 spectral lines of carbon monoxide, which they interpreted as a signature of atmospheric winds flowing from dayside to nightside toward Earth along the planet's terminator. Although the detection is tentative, these observations pave the way for an entirely new approach to characterizing hot Jupiter meteorology. Motivated by these observations, we describe the types of Doppler signatures generated by the atmospheric circulation and show how Doppler measurements can place powerful constraints on the meteorology. We show that, depending on parameters, the atmospheric circulation—and Doppler signature—of hot Jupiters split into two regimes. In one regime, at moderate stellar insolation, the day-night thermal forcing generates fast east-west jet streams from the interaction of standing planetary-scale waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows strongly toward Earth in some regions and away from Earth in others, leading to a bimodal Doppler signature exhibiting distinct, superposed blue- and redshifted velocity peaks. In the other regime, which occurs at intense stellar insolation, the thermal forcing is so strong that it damps these planetary-scale waves, inhibiting their ability to generate jet streams. As a result, this second regime exhibits a circulation dominated primarily by highaltitude, day-to-night airflow along both terminators rather than longitudinally symmetric jets. This implies that air flows toward Earth along most of the terminator, leading to a predominantly blueshifted Doppler signature during

  3. Non-Gaussianity and CMB aberration and Doppler

    SciTech Connect

    Catena, Riccardo; Liguori, Michele; Renzi, Alessandro; Notari, Alessio E-mail: michele.liguori@pd.infn.it E-mail: arenzi@pd.infn.it

    2013-09-01

    The peculiar motion of an observer with respect to the CMB rest frame induces a deflection in the arrival direction of the observed photons (also known as CMB aberration) and a Doppler shift in the measured photon frequencies. As a consequence, aberration and Doppler effects induce non trivial correlations between the harmonic coefficients of the observed CMB temperature maps. In this paper we investigate whether these correlations generate a bias on non-Gaussianity estimators f{sub NL}. We perform this analysis simulating a large number of temperature maps with Planck-like resolution (lmax = 2000) as different realizations of the same cosmological fiducial model (WMAP7yr). We then add to these maps aberration and Doppler effects employing a modified version of the HEALPix code. We finally evaluate a generalization of the Komatsu, Spergel and Wandelt non-Gaussianity estimator for all the simulated maps, both when peculiar velocity effects have been considered and when these phenomena have been neglected. Using the value v/c = 1.23 × 10{sup −3} for our peculiar velocity, we found that the aberration/Doppler induced non-Gaussian signal is at most of about half of the cosmic variance σ for f{sub NL} both in a full-sky and in a cut-sky experimental configuration, for local, equilateral and orthogonal estimators. We conclude therefore that when estimating f{sub NL} it is safe to ignore aberration and Doppler effects if the primordial map is already Gaussian. More work is necessary however to assess whether a map which contains non-Gaussianity can be significantly distorted by a peculiar velocity.

  4. Diagnosis and assessment of pulmonary vascular disease by Doppler echocardiography

    PubMed Central

    Roberts, Justin D.; Forfia, Paul R.

    2011-01-01

    Pulmonary hypertension (PH) is a relatively misunderstood disease, partly related to the fact that many perceive PH to be a singular diagnosis. An unintended consequence of this is the misapplication of the role of the Doppler-Echocardiographic (DE) examination, as well as an underappreciation for its ability to help discern PH pathophysiology prior to right heart catheterization. Since DE often serves as the “gatekeeper” to invasive right heart catheterization, misinterpretation of the DE can lead to missed or delayed diagnosis with devastating consequences. Too often, the primary or nearly exclusive focus of the DE examination is placed on the pulmonary artery pressure estimation. Two main issues with this approach are that Doppler pressure estimations can be inaccurate and even when accurate, without integration of additional 2-D and Doppler information, the clinician will often still not appreciate the pathophysiology of the PH nor its clinical significance. This review will focus on the 2-D and Doppler features necessary to assess pulmonary vascular disease (PVD), discern the salient differences between PVD and pulmonary venous hypertension (PVH), and how to integrate these key DE parameters such that PH pathophysiology can be determined noninvasively and early in the patient workup. Overreliance on any single DE metric, and especially PA pressure estimation, detracts from the overall diagnostic potential of the DE examination. Integrating the relative balance of right and left heart findings, along with proper Doppler interpretation provides a wealth of clinical and pathophysiologic insight prior to invasive hemodynamic assessment. The end results are heightened awareness and improved identification of which patients should be referred for further invasive testing, as well the use of the DE information to compliment the findings from invasive testing. PMID:22034604

  5. The influence of ocular pulsatility on scanning laser Doppler flowmetry.

    PubMed

    Sullivan, P; Cioffi, G A; Wang, L; Johnson, C A; Van Buskirk, E M; Sherman, K R; Bacon, D R

    1999-07-01

    To determine the effect of the cardiac cycle on scanning laser Doppler flowmeter measurements of retinal capillary blood flow in rhesus monkeys and humans. Multiple scanning laser Doppler flowmetry images of rhesus monkey and human retinal capillary blood flow over a range of heart rates were obtained. Average flow values were determined for the 64 scan lines that compose the two-dimensional flow map. Cutaneous blood flow was measured simultaneously with a laser Doppler flowmeter. The temporal relationships between retinal capillary blood flow, peripheral arterial pulse, and cutaneous blood flow were determined. In addition, human retinal capillary blood flow in a 10 x 10-pixel area during different phases of the cardiac cycle was compared. Regular oscillations in human and rhesus monkey retinal capillary blood flow are evident as alternating bright and dark horizontal bands in scanning laser Doppler flowmetry images. These fluctuations are temporally correlated with cutaneous blood flow. Linear regression of actual vs predicted heart rate based on peaks in retinal capillary flow yielded r = 0.999 in a rhesus monkey and 0.938 in a human. Retinal capillary blood flow in a 10 x 10-pixel area fluctuated as much as 50% depending on the phase of the cardiac cycle. The alternating bright and dark banding pattern observed in scanning laser Doppler flowmetry scans of retinal capillary blood flow is related to the cardiac pulse. The errors introduced by pulse-related fluctuations in retinal capillary blood flow are significant and must be minimized or corrected for accurate and reproducible measurements of ocular hemodynamics.

  6. Observation of Doppler broadening in β -delayed proton- γ decay

    DOE PAGES

    Schwartz, S. B.; Wrede, C.; Bennett, M. B.; ...

    2015-09-14

    Background: The Doppler broadening of gamma-ray peaks is due to nuclear recoil from beta-delayed nucleon emission can be used to measure the energies of the nucleons. This method has never been tested using beta-delayed proton emission or applied to a recoil heavier than A = 10. Purpose: To test and apply this Doppler broadening method using gamma-ray peaks from the P-26(beta p gamma)Al-25 decay sequence. Methods: A fast beam of P-26 was implanted into a planar Ge detector, which was used as a P-26 beta-decay trigger. The SeGA array of high-purity Ge detectors was used to detect gamma rays frommore » the P-26(beta p gamma)Al-25 decay sequence. Results: Radiative Doppler broadening in beta-delayed proton-gamma decay was observed for the first time. Moreover, the Doppler broadening analysis method was verified using the 1613-keV gamma-ray line for which the proton energies were previously known. The 1776-keV gamma ray de-exciting the 2720 keV Al-25 level was observed in P-26(beta p gamma)Al-25 decay for the first time and used to determine that the center-of-mass energy of the proton emission feeding the 2720-keV level is 5.1 +/- 1.0 (stat.) +/- 0.6 (syst.) MeV, corresponding to a Si-26 excitation energy of 13.3 +/- 1.0 (stat.) +/- 0.6 (syst.) MeV for the proton-emitting level. Conclusions: Finally, the Doppler broadening method has been demonstrated to provide practical measurements of the energies for beta-delayed nucleon emissions populating excited states of nuclear recoils at least as heavy as A = 25.« less

  7. Real-time high-velocity resolution color Doppler OCT

    NASA Astrophysics Data System (ADS)

    Westphal, Volker; Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2001-05-01

    Color Doppler optical coherence tomography (CDOCT), also called Optical Doppler Tomography) is a noninvasive optical imaging technique, which allows for micron-scale physiological flow mapping simultaneous with morphological OCT imaging. Current systems for real-time endoscopic optical coherence tomography (EOCT) would be enhanced by the capability to visualize sub-surface blood flow for applications in early cancer diagnosis and the management of bleeding ulcers. Unfortunately, previous implementations of CDOCT have either been sufficiently computationally expensive (employing Fourier or Hilbert transform techniques) to rule out real-time imaging of flow, or have been restricted to imaging of excessively high flow velocities when used in real time. We have developed a novel Doppler OCT signal-processing strategy capable of imaging physiological flow rates in real time. This strategy employs cross-correlation processing of sequential A-scans in an EOCT image, as opposed to autocorrelation processing as described previously. To measure Doppler shifts in the kHz range using this technique, it was necessary to stabilize the EOCT interferometer center frequency, eliminate parasitic phase noise, and to construct a digital cross correlation unit able to correlate signals of megahertz bandwidth by a fixed lag of up to a few ms. The performance of the color Doppler OCT system was demonstrated in a flow phantom, demonstrating a minimum detectable flow velocity of ~0.8 mm/s at a data acquisition rate of 8 images/second (with 480 A-scans/image) using a handheld probe. Dynamic flow as well as using it freehanded was shown. Flow was also detectable in a phantom in combination with a clinical usable endoscopic probe.

  8. Coherent Doppler lidar signal covariance including wind shear and wind turbulence

    NASA Technical Reports Server (NTRS)

    Frehlich, R. G.

    1993-01-01

    The performance of coherent Doppler lidar is determined by the statistics of the coherent Doppler signal. The derivation and calculation of the covariance of the Doppler lidar signal is presented for random atmospheric wind fields with wind shear. The random component is described by a Kolmogorov turbulence spectrum. The signal parameters are clarified for a general coherent Doppler lidar system. There are two distinct physical regimes: one where the transmitted pulse determines the signal statistics and the other where the wind field dominates the signal statistics. The Doppler shift of the signal is identified in terms of the wind field and system parameters.

  9. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    PubMed

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p < 0.001), in TAMx of 53.2% (p < 0.001) and 38.3% (p = 0.002), and in TAMn of 84.4% (p < 0.001) and 68.2% (p < 0.001). Semiquantitative power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  10. Micro-Doppler analysis of multiple frequency continuous wave radar signatures

    NASA Astrophysics Data System (ADS)

    Anderson, Michael G.; Rogers, Robert L.

    2007-04-01

    Micro-Doppler refers to Doppler scattering returns produced by non rigid-body motion. Micro-Doppler gives rise to many detailed radar image features in addition to those associated with bulk target motion. Targets of different classes (for example, humans, animals, and vehicles) produce micro-Doppler images that are often distinguishable even by nonexpert observers. Micro-Doppler features have great potential for use in automatic target classification algorithms. Although the potential benefit of using micro-Doppler in classification algorithms is high, relatively little experimental (non-synthetic) micro-Doppler data exists. Much of the existing experimental data comes from highly cooperative targets (human or vehicle targets directly approaching the radar). This research involved field data collection and analysis of micro-Doppler radar signatures from non-cooperative targets. The data was collected using a low cost Xband multiple frequency continuous wave (MFCW) radar with three transmit frequencies. The collected MFCW radar signatures contain data from humans, vehicles, and animals. The presented data includes micro-Doppler signatures previously unavailable in the literature such as crawling humans and various animal species. The animal micro-Doppler signatures include deer, dog, and goat datasets. This research focuses on the analysis of micro-Doppler from noncooperative targets approaching the radar at various angles, maneuvers, and postures.

  11. Note: Laser Doppler velocimeter using a dual-longitudinal-mode laser source

    NASA Astrophysics Data System (ADS)

    Xiaoming, Nie; Jian, Zhou; Xingwu, Long

    2012-10-01

    This paper presents a new laser Doppler technique using a dual-longitudinal-mode He-Ne laser as the laser source. Theoretical analysis shows that the Doppler frequency is proportional with the frequency difference of the two modes. The Doppler frequency in this technique is very low compared with the one in the single-mode laser Doppler technique. The new laser Doppler technique can be used to measure high speed. Experiment results show that the Doppler frequency is only about 82 Hz while the measurement speed reaches 31.4 m/s. The signal-to-noise ratio of the Doppler signal is improved by the technique of digital filter and digital autocorrelation.

  12. An Externally Dispersed Interferometer for Sensitive Doppler Extrasolar Planet Searches

    NASA Astrophysics Data System (ADS)

    Ge, Jian; Erskine, David J.; Rushford, Mike

    2002-09-01

    A new kind of instrument for sensitive Doppler extrasolar planet searches, called an externally dispersed interferometer, is described in this paper. It is a combination of an optical Michelson-type interferometer and an intermediate-resolution grating spectrometer. The interferometer measures Doppler radial velocity (RV) variations of starlight through the phase shifts of moiré fringes, created by multiplication of the interferometer fringes with stellar absorption lines. The intermediate-resolution spectrograph disperses the moiré fringes into thousands of parallel-wavelength channels. This increases the instrument bandwidth and fringe visibility by preventing fringe cross-talk between neighboring spectral lines. This results in a net increase in the signal-to-noise ratio over an interferometer used alone with broadband light. Compared to current echelle spectrometers for extrasolar planet searches, this instrument offers two unique instrument properties: a simple, stable, well-defined sinusoidal instrument response function (point-spread function) and magnification of Doppler motion through moiré fringe techniques. Since instrument noise is chiefly limited by the ability to characterize the instrument response, this new technique provides unprecedented low instrumental noise in an economical compact apparatus, enabling higher precision for Doppler RV measurements. In practice, the moiré magnification can be 5-10 times depending on the interferometer comb angle. This instrument has better sensitivity for smaller Doppler shifts than echelle spectrometers. The instrument can be designed with much lower spectral resolving power without losing Doppler sensitivity and optimized for higher throughput than echelle spectrometers to allow a potential survey for planets around fainter stars than current magnitude limits. Lab-based experiments with a prototype instrument with a spectral resolution of R~20,000 demonstrated ~0.7 m s-1 precision for short-term RV

  13. Spaceborne Simulations of Two Direct-Detection Doppler Lidar Techniques

    NASA Technical Reports Server (NTRS)

    McGill, Matthew J.; Li, Steve X.

    1998-01-01

    Direct-detection (or incoherent) lidar is now a proven technique for measuring winds in the atmosphere. Over the last few years, several types of direct-detection lidar have evolved. These methods rely on Fabry-Perot interferometers(also termed etalons) or other narrow-passband filters to provide the required spectral resolution. One method, now called the edge (EDG) technique, uses a sharply-sloping filter and measures changes in the filter transmission caused by Doppler shifting of the laser wavelength. A variation of the EDG method, called the double-edge (DEDG) technique, uses two filters. The molecular DEDG method was first demonstrated by Chanin et al. for stratospheric measurements and more recently Korb et al. successfully demonstrated the aerosol DEDG through the troposphere. A second method, here termed the multi-channel (MC) technique, measures Doppler shifts by observing angular displacement of a Fabry-Perot fringe in a spatially resolving detector. The EDG technique thus employs the Fabry-Perot to convert the frequency shift into an amplitude signal, while the MC technique uses the Fabry-Perot to resolve the spectral signature which is then fitted to determine the centroid. The focus of this presentation is on the DEDG and MC methods because these are viewed as the current state of the art in direct-detection lidar. Successful ground-based demonstrations of direct-detection wind measurements have resulted in proposals for spaceborne systems. With this new emphasis on spaceborne systems comes the need for accurate prediction of spaceborne direct-detection Doppler lidar performance. Previously, the EDG and MC methods have been compared although only for aerosol Doppler systems. A recent paper by McGill and Spinhirne compares the DEDG and MC methods in a non-system specific manner for both the aerosol and molecular Doppler systems. The purpose of this presentation is to extend the previous work of McGill and Spinhirne to examine the performance of

  14. Spaceborne Simulations of Two Direct-Detection Doppler Lidar Techniques

    NASA Technical Reports Server (NTRS)

    McGill, Matthew J.; Li, Steve X.

    1998-01-01

    Direct-detection (or incoherent) lidar is now a proven technique for measuring winds in the atmosphere. Over the last few years, several types of direct-detection lidar have evolved. These methods rely on Fabry-Perot interferometers(also termed etalons) or other narrow-passband filters to provide the required spectral resolution. One method, now called the edge (EDG) technique, uses a sharply-sloping filter and measures changes in the filter transmission caused by Doppler shifting of the laser wavelength. A variation of the EDG method, called the double-edge (DEDG) technique, uses two filters. The molecular DEDG method was first demonstrated by Chanin et al. for stratospheric measurements and more recently Korb et al. successfully demonstrated the aerosol DEDG through the troposphere. A second method, here termed the multi-channel (MC) technique, measures Doppler shifts by observing angular displacement of a Fabry-Perot fringe in a spatially resolving detector. The EDG technique thus employs the Fabry-Perot to convert the frequency shift into an amplitude signal, while the MC technique uses the Fabry-Perot to resolve the spectral signature which is then fitted to determine the centroid. The focus of this presentation is on the DEDG and MC methods because these are viewed as the current state of the art in direct-detection lidar. Successful ground-based demonstrations of direct-detection wind measurements have resulted in proposals for spaceborne systems. With this new emphasis on spaceborne systems comes the need for accurate prediction of spaceborne direct-detection Doppler lidar performance. Previously, the EDG and MC methods have been compared although only for aerosol Doppler systems. A recent paper by McGill and Spinhirne compares the DEDG and MC methods in a non-system specific manner for both the aerosol and molecular Doppler systems. The purpose of this presentation is to extend the previous work of McGill and Spinhirne to examine the performance of

  15. Comparison between ultrasonographic findings of benign and malignant canine mammary gland tumours using B-mode, colour Doppler, power Doppler and spectral Doppler.

    PubMed

    Soler, Marta; Dominguez, Elisabet; Lucas, Xiomara; Novellas, Rosa; Gomes-Coelho, Kassia Valeria; Espada, Yvonne; Agut, Amalia

    2016-08-01

    The aim of this study was to evaluate whether the comparison between the ultrasonographic features of canine mammary tumours, assessed by B-Mode, colour Doppler, power Doppler, spectral Doppler, and histopathologic features, would help to differentiate if a tumour is benign or malignant. Ultrasonographic examinations of 104 tumours were performed. Volume, margins, presence of a capsule, echotexture and presence and distribution of the vascular flow of the tumours were evaluated. All the tumours were surgically removed, submitted for histopathologic examination and classified in two groups: Group I (benign tumours) and Group II (malignant tumours). Echotexture was the only parameter evaluated by B-Mode ultrasonography where significant differences were found (p<0.01), with tumours in Group I being homogeneous and tumours in Group II presenting greater heterogeneity. Presence of vascular flow was observed in most of the tumours from both groups and no differences between them were found. Regarding flow distribution, significant differences were observed between groups (p<0.05). In benign tumours, the most common vascular pattern was the peripheral, showing significant differences (p<0.05) compared to mixed and central patterns. In malignant tumours the mixed pattern was the most frequent. Also significant differences among other patterns (peripheral and central) were found. Concerning vascular resistivity and pulsatility indexes, there were no significant differences between the two groups. The echotexture and type of vascular flow pattern of canine mammary gland tumours may help, in a first examination of the tumour, to differentiate between benign and malignant tumours; however to reach a definitive diagnosis histological study is required. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. A novel approach for Doppler blood flow measurement.

    PubMed

    McNamara, D M; Goli, A; Ziarani, A K

    2008-01-01

    A new approach to frequency estimation for the velocity estimation in Doppler ultrasound blood flow analysis is presented. The basis of the approach is an adaptive sinusoid-tracking algorithm which is effective in extracting nonstationary signals from within noise and estimating their time-varying parameters, such as the frequency, over time. The preliminary studies conducted using simulated signals show the potential of this approach in estimating Doppler frequency shifts under noisy conditions. A qualitative comparison with the short-time Fourier transform (STFT) is presented to show the advantages of the proposed technique over the STFT. The proposed approach offers advantages over conventional time-frequency analysis techniques in terms of high time-frequency resolution and high noise immunity.

  17. A preliminary investigation of bird classification by Doppler radar

    NASA Technical Reports Server (NTRS)

    Martinson, L. W.

    1973-01-01

    A preliminary study of the application of Doppler radar to the classification of birds is reported. The desirability for improvements in bird classification stems primarily from the hazards they present to jet aircraft in flight and in the vicinity of airports. A secondary need exists in the study of bird migration. The wing body and tail motion of a bird in flight reflect signals which, when analyzed properly present a signature of wing beat pattern which is unique for each bird species. Although the results of this investigation did not validate the feasibility of classifying bird species, they do indicate that a more thorough investigation is warranted. Certain gross characteristics such as wing beat rates, multiple bird patterns, and bird maneuverability, were indicated clearly in the results. Large birds with slow wing beat rates appear to be the most optimum subject for further study with the X-band Doppler radar used in this investigation.

  18. Application of FFT analyzed cardiac Doppler signals to fuzzy algorithm.

    PubMed

    Güler, Inan; Hardalaç, Firat; Barişçi, Necaattin

    2002-11-01

    Doppler signals, recorded from the output of tricuspid, mitral, and aorta valves of 60 patients, were transferred to a personal computer via 16-bit sound card. The fast Fourier transform (FFT) method was applied to the recorded signal from each patient. Since FFT method inherently cannot offer a good spectral resolution at highly turbulent blood flows, it sometimes leads to wrong interpretation of cardiac Doppler signals. In order to avoid this problem, firstly six known diseased heart signals such as hypertension, mitral stenosis, mitral failure, tricuspid stenosis, aorta stenosis, aorta insufficiency were introduced to fuzzy algorithm. Then, the unknown heart diseases from 15 patients were applied to the same fuzzy algorithm in order to detect the kinds of diseases. It is observed that the fuzzy algorithm gives true results for detecting the kind of diseases.

  19. Multipath and Doppler observations during transatlantic digital HF propagation experiments

    NASA Astrophysics Data System (ADS)

    Reinisch, B. W.; Bibl, K.; Ahmed, M.; Soicher, H.; Gorman, F.; Jodogne, J. C.

    1984-10-01

    Digital HF transatlantic propagation experiments between two nodes at Dourbes, Belgium, and Needham, MA, using identical digisonde 256 systems became operational in October 1983. Adaptive two way sounding and real time channel evaluation studies are to be conducted among the network's nodes. Presently, the Dourbes station is transmitting 10 kW pulses using a horizontal rhombic antenna while the Needham station uses a long-periodic antenna for both transmission and reception. Amplitude and Doppler shifts of different multipath modes were measured during magnetically quiescent and disturbed periods for the first month of operation. The pulse modulation enables clear separation and identification of the multihop paths. Real time discrete Fourier transforms determine the Doppler shifts imposed by height changes of the reflecting ionospheric layers. A comparison of the observed MUF's of the dominant 2F mode with the MUF's predicted by the IONCAP model show the latter to be about 20 to 30% higher.

  20. Laser Doppler velocimeter system simulation for sensing aircraft wake vortices

    NASA Technical Reports Server (NTRS)

    Thomson, J. A. L.; Meng, J. C. S.

    1974-01-01

    A hydrodynamic model of aircraft vortex wakes in an irregular wind shear field near the ground is developed and used as a basis for modeling the characteristics of a laser Doppler detection and vortex location system. The trailing vortex sheet and the wind shear are represented by discrete free vortices distributed over a two-dimensional grid. The time dependent hydrodynamic equations are solved by direct numerical integration in the Boussinesq approximation. The ground boundary is simulated by images, and fast Fourier Transform techniques are used to evaluate the vorticity stream function. The atmospheric turbulence was simulated by constructing specific realizations at time equal to zero, assuming that Kolmogoroff's law applies, and that the dissipation rate is constant throughout the flow field. The response of a simulated laser Doppler velocimeter is analyzed by simulating the signal return from the flow field as sensed by a simulation of the optical/electronic system.

  1. Doppler Lidar Vertical Velocity Statistics Value-Added Product

    SciTech Connect

    Newsom, R. K.; Sivaraman, C.; Shippert, T. R.; Riihimaki, L. D.

    2015-07-01

    Accurate height-resolved measurements of higher-order statistical moments of vertical velocity fluctuations are crucial for improved understanding of turbulent mixing and diffusion, convective initiation, and cloud life cycles. The Atmospheric Radiation Measurement (ARM) Climate Research Facility operates coherent Doppler lidar systems at several sites around the globe. These instruments provide measurements of clear-air vertical velocity profiles in the lower troposphere with a nominal temporal resolution of 1 sec and height resolution of 30 m. The purpose of the Doppler lidar vertical velocity statistics (DLWSTATS) value-added product (VAP) is to produce height- and time-resolved estimates of vertical velocity variance, skewness, and kurtosis from these raw measurements. The VAP also produces estimates of cloud properties, including cloud-base height (CBH), cloud frequency, cloud-base vertical velocity, and cloud-base updraft fraction.

  2. Novel Doppler laser radar for diagnostics in fusion reactors

    SciTech Connect

    Menon, Madhavan; Slotwinski, Anthony

    2004-10-01

    We describe the development of a novel Doppler laser radar (DOLAR) for remote measurement of flow velocity (0-10 m/s) and film thickness of liquid metal walls, currently being studied for their superior heat handling and self-healing characteristics. Small fluctuations in flow velocity({approx}mm/s) and flow thickness ({approx}50 {mu}m) that may arise during plasma discharges can also be measured. The DOLAR is also designed for non intrusive mapping of features of plasma-facing solid surfaces with very high precision ({approx}50 {mu}m). It can also measure the motion of structural components of a fusion reactor during plasma discharges and during plasma disruptions. The device utilizes frequency modulation laser radar principles for precision range measurements. Compensation of Doppler frequency shift is used to measure flow velocity. The DOLAR probe head is designed with acousto-optic and piezoelectric devices for operation in the harsh fusion environment.

  3. Simultaneous fetal magnetocardiography and ultrasound/Doppler imaging.

    PubMed

    Zhao, Hui; Chen, Mingli; Van Veen, Barry D; Strasburger, Janette F; Wakai, Ronald T

    2007-06-01

    The difficulty of utilizing multimodality diagnostic imaging techniques for fetal surveillance remains one of the greatest challenges in providing enhanced prenatal care. In this Letter we demonstrate the feasibility of performing fetal magnetocardiography (fMCG) and ultrasound/Doppler imaging simultaneously, using a multichannel SQUID magnetometer and a portable ultrasound scanner. Despite large magnetic interference from the scanner, the implementation of simple noise reduction procedures and appropriate signal processing techniques yielded fMCG recordings of sufficient quality for assessment of fetal heart rate and rhythm. A variation of reference channel filtering, referred to here as synthetic reference channel filtering, was used to reduce nonstationary low-frequency interference. The combination of fMCG and/or fMEG with ultrasound/Doppler offers new possibilities for assessment of fetal well-being and fetal cardiac function.

  4. Laser Doppler anemometer studies in unsteady ventricular flows.

    PubMed

    Phillips, W M; Furkay, S S; Pierce, W S

    1979-01-01

    The laser Doppler technique was employed to obtain intraventricular velocity distributions on the basis of in vivo confirmation of previous in vitro flow visualization predictions. The quasi-steady assumption required for quantification of flow visualization results is unsatisfactory in regions of high acceleration and fluctuating velocities are unavailable via such techniques. Mean and fluctuating velocity profiles were obtained in a pneumatically driven prosthetic ventricle with the laser Doppler anemometer and stress levels estimated. The preliminary data presented here illustrates that the technique can be applied to such flows. The measurement and data reduction schemes are applicable to a wide range of simulated cardiovascular flows. The particular application to prosthetic ventricle design should minimize the number of in vivo experiments required to develop a satisfactory blood pump and aid in tailoring pump actuation protocols for minimum thromboembolic complications.

  5. All semiconductor laser Doppler anemometer at 1.55 microm.

    PubMed

    Hansen, René Skov; Pedersen, Christian

    2008-10-27

    We report to our best knowledge the first all semiconductor Laser Doppler Anemometer (LIDAR) for wind speed determination. We will present the design and first experimental results on a focusing coherent cw laser Doppler anemometer for measuring atmospheric wind velocities in the 10 meters to 300 meters distance range. Especially, we will demonstrate that both the output power as well as the demanding coherence properties required from the laser source can be accomplished by an all semiconductor laser. Preliminary tests at a distance of 40 meters indicate a typical signal to noise ratio of 9 dB. This result is obtained at a clear day with an up-date rate of 12 Hz.

  6. HF Doppler observations of acoustic waves excited by the earthquake

    NASA Technical Reports Server (NTRS)

    Ichinose, T.; Takagi, K.; Tanaka, T.; Okuzawa, T.; Shibata, T.; Sato, Y.; Nagasawa, C.; Ogawa, T.

    1985-01-01

    Ionospheric disturbances caused by the earthquake of a relatively small and large epicentral distance have been detected by a network of HF-Doppler sounders in central Japan and Kyoto station, respectively. The HF-Doppler data of a small epicentral distance, together with the seismic data, have been used to formulate a mechanism whereby ionospheric disturbances are produced by the Urakawa-Oki earthquake in Japan. Comparison of the dynamic spectra of these data has revealed experimentally that the atmosphere acts as a low-pass filter for upward-propagating acoustic waves. By surveying the earthquakes for which the magnitude M is larger than 6.0, researchers found the ionospheric effect in 16 cases of 82 seismic events. As almost all these effects have occurred in the daytime, it is considered that it may result from the filtering effect of the upward-propagating acoustic waves.

  7. Ge's Mobile, Coherent Doppler Lidar Test/Ealuation Facilities

    NASA Technical Reports Server (NTRS)

    Sroga, J. T.; Scott, J. W.; Kiernan, S. C.; Weaver, F. J.; Trotta, J. E.; Petheram, J. C.

    1992-01-01

    The primary objective of this independent research and development (IR and D) program in support of the Laser Atmospheric Wind Sounder (LAWS) program is to develop and evaluate technologies with direct applications to spaceborne laser wind sensing, and to develop system level engineering experience in designing, operating, and modeling a coherent Doppler lidar. GE is developing a mobile, ground based coherent Doppler lidar as an end-to-end system level test facility to evaluate applicable technologies, verify system level performance issues, perform instrument calibration, and validate end-to-end system performance model predictions. Here, the primary focus is on a description of the ground based lidar system and the performance during the initial shakedown operation after system integration.

  8. Multipoint photonic doppler velocimetry using optical lens elements

    SciTech Connect

    Frogget, Brent Copely; Romero, Vincent Todd

    2014-04-29

    A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

  9. Normal and anomalous Doppler effects in periodic waveguide cyclotron maser

    SciTech Connect

    Korol, M.; Jerby, E.

    1995-12-31

    A linear analysis of the periodic-waveguide cyclotron (PWC) maser shows that the PWC interaction with fast-waves possesses properties of the known anomalous Doppler resonance interaction if the wave impedance of the resonant spatial harmonic, Z{sub n}, is much smaller than the free space impedance, i.e. if Z{sub n} {much_lt} Z{sub 0}. The feasibility of a fast-wave PWC interaction in a low impedance waveguide is examined theoretically in this paper. A practical scheme of a slotted-waveguide PWC operating in the fundamental harmonic near cutoff is proposed for a future experiment. The possible advantages of the quasi-anomalous Doppler effect in the fast-wave-PWC operating regime are the alleviation of the initial electron rotation and a high-efficiency operation.

  10. Performance evaluation of a thermal Doppler Michelson interferometer system.

    PubMed

    Mani, Reza; Dobbie, Steven; Scott, Alan; Shepherd, Gordon; Gault, William; Brown, Stephen

    2005-11-20

    The thermal Doppler Michelson interferometer is the primary element of a proposed limb-viewing satellite instrument called SWIFT (Stratospheric Wind Interferometer for Transport studies). SWIFT is intended to measure stratospheric wind velocities in the altitude range of 15-45 km. SWIFT also uses narrowband tandem etalon filters made of germanium to select a line out of the thermal spectrum. The instrument uses the same technique of phase-stepping interferometry employed by the Wind Imaging Interferometer onboard the Upper Atmosphere Research Satellite. A thermal emission line of ozone near 9 microm is used to detect the Doppler shift due to winds. A test bed was set up for this instrument that included the Michelson interferometer and the etalon filters. For the test bed work, we investigate the behavior of individual components and their combination and report the results.

  11. Doppler broadening in the β-proton- γ decay sequence

    NASA Astrophysics Data System (ADS)

    Schwartz, Sarah; Wrede, C.; Bennett, M. B.; Liddick, S. N.; Perez-Loureiro, D.; Bowe, A.; Chen, A. A.; Chipps, K. A.; Cooper, N.; Irvine, D.; McNeice, E.; Montes, F.; Naqvi, F.; Ortez, R.; Pain, S. D.; Pereira, J.; Prokop, C.; Quaglia, J.; Quinn, S. J.; Sakstrup, J.; Santia, M.; Shanab, S.; Simon, A.; Spyrou, A.; Thiagalingam, E.

    2015-10-01

    We report the first observation of Doppler-broadening in β delayed proton- γ decay. The broadening occurs because the daughter nucleus γ decays while recoiling from proton emission. A method to analyze β delayed nucleon emission was applied to two Doppler-broadened 25Al peaks from the 26P(βpγ)25Al decay. The method was first tested on the broad 1613 keV γ-ray peak using known center-of-mass proton energies as constraints. The method was then applied to the 1776 keV γ-ray peak from the 2720 keV excited state of 25Al. The broadening was used to determine a 26Si excitation energy of 13.3 +/- 1.0 (stat.) +/- 0.7 (syst.) MeV. This energy is consistent with proton emission from the known T = 2 isobaric analog state of 26P in 26Si.

  12. Microwave Doppler reflectometer system in the Experimental Advanced Superconducting Tokamak.

    PubMed

    Zhou, C; Liu, A D; Zhang, X H; Hu, J Q; Wang, M Y; Li, H; Lan, T; Xie, J L; Sun, X; Ding, W X; Liu, W D; Yu, C X

    2013-10-01

    A Doppler reflectometer system has recently been installed in the Experimental Advanced Superconducting (EAST) Tokamak. It includes two separated systems, one for Q-band (33-50 GHz) and the other for V-band (50-75 GHz). The optical system consists of a flat mirror and a parabolic mirror which are optimized to improve the spectral resolution. A synthesizer is used as the source and a 20 MHz single band frequency modulator is used to get a differential frequency for heterodyne detection. Ray tracing simulations are used to calculate the scattering location and the perpendicular wave number. In EAST last experimental campaign, the Doppler shifted signals have been obtained and the radial profiles of the perpendicular propagation velocity during L-mode and H-mode are calculated.

  13. Doppler lidar for measurement of atmospheric wind fields

    SciTech Connect

    Menzies, R.T. )

    1991-01-01

    Measurements of wind fields in the earth's troposphere with daily global coverage is widely considered as a significant advance for forecasting and transport studies. For optimal use by NWP (Numerical Weather Prediction) models the horizontal and vertical resolutions should be approximately 100 km and 1 km, respectively. For boundary layer studies vertical resolution of a few hundred meters seems essential. Earth-orbiting Doppler lidar has a unique capability to measure global winds in the troposphere with the high vertical resolution required. The lidar approach depends on transmission of pulses with high spectral purity and backscattering from the atmospheric aerosol particles or layered clouds to provide a return signal. Recent field measurement campaigns using NASA research aircraft have resulted in collection of aerosol and cloud data which can be used to optimize the Doppler lidar instrument design and measurement strategy. 5 refs.

  14. Doppler aortic flow velocity measurement in healthy children.

    PubMed Central

    Sohn, S.; Kim, H. S.

    2001-01-01

    To determine normal values for Doppler parameters of left ventricular function, ascending aortic blood flow velocity was measured by pulsed wave Doppler echocardiography in 63 healthy children with body surface area (BSA) < 1 m(2) (age < 10 yr). Peak velocity was independent of sex, but increased with body size. Mean acceleration was related to peak velocity (r = 0.75, p < 0.0001). Both stroke distance and ejection time had strong negative correlations with heart rate and positive correlations with BSA, suggesting that these parameters should be evaluated in relation to heart rate and body size. Mean intra- and interobserver variability for peak velocity, ejection time, stroke and minute distance ranged from 3 to 7%, whereas variability for acceleration time was 9 to 13%. These data may be used as reference values for the assessment of hemodynamic states in young children with cardiac disease. PMID:11306737

  15. Photonic Doppler velocimetry lens array probe incorporating stereo imaging

    DOEpatents

    Malone, Robert M.; Kaufman, Morris I.

    2015-09-01

    A probe including a multiple lens array is disclosed to measure velocity distribution of a moving surface along many lines of sight. Laser light, directed to the moving surface is reflected back from the surface and is Doppler shifted, collected into the array, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to the multiple lens array. Numerous fibers in a fiber array project numerous rays to establish many measurement points at numerous different locations. One or more lens groups may be replaced with imaging lenses so a stereo image of the moving surface can be recorded. Imaging a portion of the surface during initial travel can determine whether the surface is breaking up.

  16. Doppler centroid estimation ambiguity for synthetic aperture radars

    NASA Technical Reports Server (NTRS)

    Chang, C. Y.; Curlander, J. C.

    1989-01-01

    A technique for estimation of the Doppler centroid of an SAR in the presence of large uncertainty in antenna boresight pointing is described. Also investigated is the image degradation resulting from data processing that uses an ambiguous centroid. Two approaches for resolving ambiguities in Doppler centroid estimation (DCE) are presented: the range cross-correlation technique and the multiple-PRF (pulse repetition frequency) technique. Because other design factors control the PRF selection for SAR, a generalized algorithm is derived for PRFs not containing a common divisor. An example using the SIR-C parameters illustrates that this algorithm is capable of resolving the C-band DCE ambiguities for antenna pointing uncertainties of about 2-3 deg.

  17. Endovaginal US and Doppler findings after first-trimester abortion.

    PubMed

    Dillon, E H; Case, C Q; Ramos, I M; Holland, C K; Taylor, K J

    1993-01-01

    Endovaginal ultrasound (US) imaging and color Doppler flow imaging techniques were used to evaluate the uterus and its contents and to establish characteristics of a normal post-abortion appearance in 19 women who underwent elective first-trimester abortions. Twenty-two examinations were performed between 2 and 17 days after the procedure. Thirteen of the 22 examinations (59%) showed different amounts of intrauterine material of varying echogenicity. Seven of the 22 examinations (32%) showed a thick endometrial stripe, and only two showed a normal stripe. Color Doppler flow imaging demonstrated typical peritrophoblastic flow in four of eight patients on the second and third days after the abortions were performed. After the third day, flow was observed in only two of 11 patients, and intrauterine material was also seen. These results indicate that intrauterine material and low-impedance flow are frequently observed after an abortion and do not necessarily indicate clinically important retained products of conception.

  18. Normal Doppler velocimetry of renal vasculature in Persian cats.

    PubMed

    Carvalho, Cibele F; Chammas, Maria C

    2011-06-01

    Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m

  19. Tracking driver's heart rate by continuous-wave Doppler radar.

    PubMed

    Kwang Jin Lee; Chanki Park; Boreom Lee

    2016-08-01

    Developing driving safety system with medical assistance devices for preventing accidents has become a major social issue in recent year. These devices have been developed using electrocardiogram (ECG) and photoplethysmogram (PPG) for measuring the heart rate (HR). However, driver should directly contact with the sensor for monitoring the HR. Recently, non-contact system based on continuous-wave Doppler radar has widely studied for monitoring HR. The periodogram by Fast Fourier Transform (FFT) was used for estimating HR. However, if motion artifacts by movement of driver and vehicle vibration contaminate the radar signal, we cannot find spectral peak of HR using FFT. In this paper, we propose a method using multiple signal classification (MUSIC) for estimating HR. We compared MUSIC algorithms with a commonly used FFT method using real experiment data while driving. The results indicate that our proposed method can estimate HR accurately from received radar Doppler signal with motion artifacts.

  20. Using Doppler Shifts of GPS Signals To Measure Angular Speed

    NASA Technical Reports Server (NTRS)

    Campbell, Charles E., Jr.

    2006-01-01

    A method has been proposed for extracting information on the rate of rotation of an aircraft, spacecraft, or other body from differential Doppler shifts of Global Positioning System (GPS) signals received by antennas mounted on the body. In principle, the method should be capable of yielding low-noise estimates of rates of rotation. The method could eliminate the need for gyroscopes to measure rates of rotation. The method is based on the fact that for a given signal of frequency ft transmitted by a given GPS satellite, the differential Doppler shift is attributable to the difference between those components of the instantaneous translational velocities of the antennas that lie along the line of sight from the antennas to the GPS satellite.

  1. Ultrasonic Doppler measurement of renal artery blood flow

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

  2. An integrated microwave Doppler cinemometer for transport applications

    NASA Astrophysics Data System (ADS)

    Descamps, P.; Bekkali, M. El; Vindevoghel, J.

    1991-08-01

    In order to automate the driving of terrestrial vehicles it is necessary to know at any time and with the highest accuracy the values of the speed of the vehicle and of the distance covered by the vehicle; it is also necessary to know the direction of the motion relative to the ground. These values must be measured in the real-time domain and this involves that contactless and very low time-constant sensors must be used. On the other hand, the applications concerned ask for a miniaturization of the whole measurement system. For these reasons, sensors using the Doppler effect in the microwave range are particularly well convenient to these applications. We developed an X band microwave Doppler cinemometer (MDC) with a printed antenna that is built using microstrip technology.

  3. An ideal blood mimicking fluid for doppler ultrasound phantoms.

    PubMed

    Samavat, H; Evans, J A

    2006-10-01

    In order to investigate the problems of detecting tumours by ultrasound it is very important to have a portable Doppler flow test object to use as a standardising tool. The flow Doppler test objects are intended to mimic the flow in human arteries. To make the test meaningful, the acoustic properties of the main test object components (tissue and blood mimic) should match closely the properties of the corresponding human tissues, while the tube should ideally have little influence. The blood mimic should also represent the haemodynamic properties of blood. An acceptable flow test object has been designed to closely mimic blood flow in arteries. We have evaluated the properties of three blood mimicking fluid: two have been described recently in the literature, the third is a local design. One of these has emerged as being particularly well matched to the necessary characteristics for in-vitro work.

  4. Laser Doppler velocimetry using a modified computer mouse

    NASA Astrophysics Data System (ADS)

    Zaron, Edward D.

    2016-10-01

    A computer mouse has been modified for use as a low-cost laser Doppler interferometer and used to measure the two-component fluid velocity of a flowing soap film. The mouse sensor contains two vertical cavity surface emitting lasers, photodiodes, and signal processing hardware integrated into a single package, approximately 1 cm2 in size, and interfaces to a host computer via a standard USB port. Using the principle of self-mixing interferometry, whereby laser light re-enters the laser cavity after being scattered from a moving target, the Doppler shift and velocity of scatterers dispersed in the flow are measured. Observations of the boundary layer in a turbulent soap film channel flow demonstrate the capabilities of the sensor.

  5. Multipath induced errors in meteorological Doppler/interferometer location systems

    NASA Technical Reports Server (NTRS)

    Wallace, R. G.

    1984-01-01

    One application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters is in tracking high-altitude balloons for meteorological studies. A source of error in this application is reflection of the signal from the sea surface. Through propagating and signal analysis, the magnitude of the reflection-induced error in both Doppler frequency measurements and interferometer phase measurements was estimated. The theory of diffuse scattering from random surfaces was applied to obtain the power spectral density of the reflected signal. The processing of the combined direct and reflected signals was then analyzed to find the statistics of the measurement error. It was found that the error varies greatly during the satellite overpass and attains its maximum value at closest approach. The maximum values of interferometer phase error and Doppler frequency error found for the system configuration considered were comparable to thermal noise-induced error.

  6. Wind measurements with the High Resolution Doppler Imager (HRDI)

    NASA Technical Reports Server (NTRS)

    Skinner, W. R.; Hays, P. B.; Abreu, V. J.

    1985-01-01

    The Upper Atmosphere Research Satellite (UARS), to be launched in 1989, is to provide a global data set required to understand the mechanisms controlling upper atmosphere structure and processes, as well as the response of the upper atmosphere to natural and human perturbations. The High Resolution Doppler Imager (HRDI) is the primary instrument for measuring the dynamics of the stratosphere and mesosphere. The goal of HRDI is to measure wind velocities in the stratosphere and mesosphere during the day and the mesosphere and thermosphere at night with an accuracy of 5 m/sec. HRDI will determine winds by measuring Doppler shifts of atmosphere absorption and emission features. Line of sight winds will be taken in two directions, thus allowing the wind vector to be formed. The HRDI instrument is overviewed. The basis of the measurement is explained, as is an outline of the instrument. Since neither instrument nor observational techniques is fully mature, only a brief sketch is presented.

  7. Augmented Reality Based Doppler Lidar Data Visualization: Promises and Challenges

    NASA Astrophysics Data System (ADS)

    Cherukuru, N. W.; Calhoun, R.

    2016-06-01

    Augmented reality (AR) is a technology in which the enables the user to view virtual content as if it existed in real world. We are exploring the possibility of using this technology to view radial velocities or processed wind vectors from a Doppler wind lidar, thus giving the user an ability to see the wind in a literal sense. This approach could find possible applications in aviation safety, atmospheric data visualization as well as in weather education and public outreach. As a proof of concept, we used the lidar data from a recent field campaign and developed a smartphone application to view the lidar scan in augmented reality. In this paper, we give a brief methodology of this feasibility study, present the challenges and promises of using AR technology in conjunction with Doppler wind lidars.

  8. Laser Doppler velocimeter measurements in a turbine stator cascade facility

    NASA Technical Reports Server (NTRS)

    Seasholtz, R. G.

    1974-01-01

    A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes in described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

  9. Laser Doppler velocimeter measurements in a turbine stator cascade facility

    NASA Technical Reports Server (NTRS)

    Seasholtz, R. G.

    1974-01-01

    A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes is described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

  10. Ionospheric S-shaped Doppler fluctuations produced by the tornadoes

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Rao, G. L.; Smith, R. E.

    1974-01-01

    A three-dimensional nine element HF-CW Doppler sounder array has been used to detect ionospheric disturbances which may be due to tornadoes. The typical events chosen in the present study occurred on November 20 and 27, 1973. Both events are apparently associated with tornadoes sighted in the Huntsville, Alabama area. The Doppler records show S-shaped waves rather than the quasi-sinusoidal waves observed in conjunction with and apparently due to thunderstorms. The wave-periods are in the range of 6 to 8 minutes instead of the 3 to 5 minute periods associated with thunderstorms. Dissipation of waves is mostly due to the evanescent effect and they cannot propagate very far from the path of the tornado center. A theory is presented which is in good agreement with the observations.

  11. Robust estimation of fetal heart rate variability using Doppler ultrasound.

    PubMed

    Fernando, Kumari L; Mathews, V John; Varner, Michael W; Clark, Edward B

    2003-08-01

    This paper presents a new measure of heart rate variability (HRV) that can be estimated using Doppler ultrasound techniques and is robust to variations in the angle of incidence of the ultrasound beam and the measurement noise. This measure employs the multiple signal characterization (MUSIC) algorithm which is a high-resolution method for estimating the frequencies of sinusoidal signals embedded in white noise from short-duration measurements. We show that the product of the square-root of the estimated signal-to-noise ratio (SNR) and the mean-square error of the frequency estimates is independent of the noise level in the signal. Since varying angles of incidence effectively changes the input SNR, this measure of HRV is robust to the input noise as well as the angle of incidence. This paper includes the results of analyzing synthetic and real Doppler ultrasound data that demonstrates the usefulness of the new measure in HRV analysis.

  12. Ionospheric S-shaped Doppler fluctuations produced by the tornadoes

    NASA Technical Reports Server (NTRS)

    Hung, R. J.; Rao, G. L.; Smith, R. E.

    1974-01-01

    A three-dimensional nine element HF-CW Doppler sounder array has been used to detect ionospheric disturbances which may be due to tornadoes. The typical events chosen in the present study occurred on November 20 and 27, 1973. Both events are apparently associated with tornadoes sighted in the Huntsville, Alabama area. The Doppler records show S-shaped waves rather than the quasi-sinusoidal waves observed in conjunction with and apparently due to thunderstorms. The wave-periods are in the range of 6 to 8 minutes instead of the 3 to 5 minute periods associated with thunderstorms. Dissipation of waves is mostly due to the evanescent effect and they cannot propagate very far from the path of the tornado center. A theory is presented which is in good agreement with the observations.

  13. Atomic Auger Doppler effects upon emission of fast photoelectrons.

    PubMed

    Simon, Marc; Püttner, Ralph; Marchenko, Tatiana; Guillemin, Renaud; Kushawaha, Rajesh K; Journel, Loïc; Goldsztejn, Gildas; Piancastelli, Maria Novella; Ablett, James M; Rueff, Jean-Pascal; Céolin, Denis

    2014-06-06

    Studies of photoemission processes induced by hard X-rays including production of energetic electrons have become feasible due to recent substantial improvement of instrumentation. Novel dynamical phenomena have become possible to investigate in this new regime. Here we show a significant change in Auger emission following 1s photoionization of neon, which we attribute to the recoil of the Ne ion induced by the emission of a fast photoelectron. Because of the preferential motion of the ionized Ne atoms along two opposite directions, an Auger Doppler shift is revealed, which manifests itself as a gradual broadening and doubling of the Auger spectral features. This Auger Doppler effect should be a general phenomenon in high-energy photoemission of both isolated atoms and molecules, which will have to be taken into account in studies of other recoil effects such as vibrational or rotational recoil in molecules, and may also have consequences in measurements in solids.

  14. Doppler centroid estimation ambiguity for synthetic aperture radars

    NASA Technical Reports Server (NTRS)

    Chang, C. Y.; Curlander, J. C.

    1989-01-01

    A technique for estimation of the Doppler centroid of an SAR in the presence of large uncertainty in antenna boresight pointing is described. Also investigated is the image degradation resulting from data processing that uses an ambiguous centroid. Two approaches for resolving ambiguities in Doppler centroid estimation (DCE) are presented: the range cross-correlation technique and the multiple-PRF (pulse repetition frequency) technique. Because other design factors control the PRF selection for SAR, a generalized algorithm is derived for PRFs not containing a common divisor. An example using the SIR-C parameters illustrates that this algorithm is capable of resolving the C-band DCE ambiguities for antenna pointing uncertainties of about 2-3 deg.

  15. Dove prism based rotating dual beam bidirectional Doppler OCT

    PubMed Central

    Blatter, Cedric; Coquoz, Séverine; Grajciar, Branislav; Singh, Amardeep S. G.; Bonesi, Marco; Werkmeister, René M.; Schmetterer, Leopold; Leitgeb, Rainer A.

    2013-01-01

    Traditional Doppler OCT is highly sensitive to motion artifacts due to the dependence on the Doppler angle. This limits its accuracy in clinical practice. To overcome this limitation, we use a bidirectional dual beam technique equipped with a novel rotating scanning scheme employing a Dove prism. The volume is probed from two distinct illumination directions with variable controlled incidence plane, allowing for reconstruction of the true flow velocity at arbitrary vessel orientations. The principle is implemented with Swept Source OCT at 1060nm with 100,000 A-Scans/s. We apply the system to resolve pulsatile retinal absolute blood velocity by performing segment scans around the optic nerve head and circumpapillary scan time series. PMID:23847742

  16. How to study the Doppler effect with Audacity software

    NASA Astrophysics Data System (ADS)

    Adriano Dias, Marco; Simeão Carvalho, Paulo; Rodrigues Ventura, Daniel

    2016-05-01

    The Doppler effect is one of the recurring themes in college and high school classes. In order to contextualize the topic and engage the students in their own learning process, we propose a simple and easily accessible activity, i.e. the analysis of the videos available on the internet by the students. The sound of the engine of the vehicle passing by the camera is recorded on the video; it is then analyzed with the free software Audacity by measuring the frequency of the sound during approach and recede of the vehicle from the observer. The speed of the vehicle is determined due to the application of Doppler effect equations for acoustic waves.

  17. Curvature affects Doppler investigation of vessels: implications for clinical practice.

    PubMed

    Balbis, S; Roatta, S; Guiot, C

    2005-01-01

    In clinical practice, blood velocity estimations from Doppler examination of curved vascular segments are normally different from those of nearby straight segments. The observed "accelerations," sometimes considered as a sort of stochastic disturbances, can actually be related to very specific physical effects due to vessel curvature (i.e., the development of nonaxial velocity [NAV] components) and the spreading of the axial velocity direction in the Doppler sample volume with respect to the insonation axis. The relevant phenomena and their dependence on the radius of curvature of the vessels and on the insonation angle are investigated with a beam-vessel geometry as close as possible to clinical setting, with the simplifying assumptions of steady flow, mild vessel curvature, uniform ultrasonic beam and complete vessel insonation. The insonation angles that minimize the errors are provided on the basis of the study results.

  18. Imaging, Doppler, and spectroscopic radars from 95 to 700 GHz

    NASA Astrophysics Data System (ADS)

    Cooper, Ken B.

    2016-05-01

    Imaging, Doppler, and spectroscopic radars from 95 to 700 GHz, all using the frequency-modulated continuous-wave technique, are in various stages of development for both defense and science applications at the Jet Propulsion Laboratory. For standoff security screening, a 340 GHz imaging radar now achieves an 8.3 Hz frame, and it has been tested using power-efficient MMIC-based active multiplier sources into its front end. That system evolved from a 680 GHz security radar platform, which has also been modified to operate in a Doppler mode for probing the dynamics of blowing sand and sensing small-amplitude target vibrations. Meanwhile, 95 and 183 GHz radars based on similar RF architectures are currently being developed to probe cometary jets in space and, using a differential absorption technique, humidity inside upper-tropospheric clouds.

  19. [The value of Doppler ultrasound studies in threatened premature labor].

    PubMed

    Jörn, H; Funk, A; Fendel, H

    1993-01-01

    95 patients were investigated using Doppler ultrasound to evaluate its usefulness during the clinical management of patients with preterm labor, preterm rupture of membranes and incompetent cervix. Cases with additional pregnancy complications as preeclampsia or intrauterine growth retardation or infection of the amnion or the birth canal were excluded from our study. We examined the umbilical artery and the uterine arteries. Predicting preterm birth we found a sensitivity of 31.4% and a specificity of 70% for the former and a sensitivity of 34.3% and a specificity of 83.3% for the latter. As a result of our investigation we have to conclude that Doppler ultrasound is not able to predict sufficiently reliable preterm birth to use it in clinical management. Normal uterine blood flow in cases with preterm labor seems to indicate birth at term in a high degree.

  20. Doppler radar fall activity detection using the wavelet transform.

    PubMed

    Su, Bo Yu; Ho, K C; Rantz, Marilyn J; Skubic, Marjorie

    2015-03-01

    We propose in this paper the use of Wavelet transform (WT) to detect human falls using a ceiling mounted Doppler range control radar. The radar senses any motions from falls as well as nonfalls due to the Doppler effect. The WT is very effective in distinguishing the falls from other activities, making it a promising technique for radar fall detection in nonobtrusive inhome elder care applications. The proposed radar fall detector consists of two stages. The prescreen stage uses the coefficients of wavelet decomposition at a given scale to identify the time locations in which fall activities may have occurred. The classification stage extracts the time-frequency content from the wavelet coefficients at many scales to form a feature vector for fall versus nonfall classification. The selection of different wavelet functions is examined to achieve better performance. Experimental results using the data from the laboratory and real inhome environments validate the promising and robust performance of the proposed detector.