General requirements to implement the personal dose equivalent Hp(10) in Brazil
NASA Astrophysics Data System (ADS)
Gomes Lopes, Amanda; Da Silva, Francisco Cesar Augusto
2018-03-01
To update the dosimetry quantity with the international community, Brazil is changing the Individual Dose (Hx) to the Personal Dose Equivalent Hp(10). A bibliographical survey on the technical and administrative requirements of nine countries that use Hp(10) was carried out to obtain the most relevant ones. All of them follow IEC and ISO guidelines for technical requirements, but administrative requirements change from country to country. Based on countries experiences, this paper presents a list of important general requirements to implement Hp(10) and to prepare the Brazilian requirements according to the international scientific community.
A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists.
Farah, J; Struelens, L; Dabin, J; Koukorava, C; Donadille, L; Jacob, S; Schnelzer, M; Auvinen, A; Vanhavere, F; Clairand, I
2013-12-01
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.
Szewczak, Kamil; Jednoróg, Sławomir; Krajewski, Paweł
2013-01-01
Presented paper describes the results of the individual doses measurements for ionizing radiation, carried out by the Laboratory of Individual and Environmental Doses Monitoring (PDIS) of the Central Laboratory for Radiological Protection in Warsaw (CLOR) for the medical staff employees in several nuclear medicine (NM) departments across Poland. In total there are48 NM departments in operation in Poland [1] (consultation in Nuclear Atomic Agency). Presented results were collected over the period from January 2011 to December 2011 at eight NM departments located in Krakow, Warszawa (two departments), Rzeszow (two departments), Opole, Przemysl and Gorzow Wielkopolski. For radiation monitoring three kinds of thermo luminescence dosimeters (TLD) were used. The first TLD h collected information about whole body (C) effective dose, the second dosimeter was mounted in the ring (P) meanwhile the third on the wrist (N) of the tested person. Reading of TLDs was performed in quarterly periods. As a good approximation of effective and equivalent dose assessment of operational quantities both the individual dose equivalent Hp(10) and the Hp(0.07) were used. The analysis of the data was performed using two methods The first method was based on quarterly estimations of Hp(10)q and Hp(0.07)q while the second measured cumulative annual doses Hp(10)a and Hp(0.07)a. The highest recorded value of the radiation dose for quarterly assessments reached 24.4 mSv and was recorded by the wrist type dosimeter worn by a worker involved in source preparation procedure. The mean values of Hp(10)q(C type dosimeter) and Hp(0.07)q (P and N type dosimeter) for all monitored departments were respectively 0.46 mSv and 3.29 mSv. There was a strong correlation between the performed job and the value of the received dose. The highest doses always were absorbed by those staff members who were involved in sources preparation. The highest annual cumulative dose for a particular worker in the considered time period was 4.22 mSv for Hp(10)a and 67.7 mSv for Hp(0.07)a. In 2011 no case of exceeding the allowed dose limits was noted.
Ubeda, Carlos; Morales, Claudio; Gutiérrez, Diego; Oliveira, Marcus; Manterola, Carlos
2018-05-11
The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured during 59 procedures. Mean values of occupational dose Hp(10) per procedure were 47.6, 6.2 and 4.3 μSv for physician, nurse and radiographer, respectively. If no protective tools are used, physician dose can exceed the new eye lens dose limit.
NASA Astrophysics Data System (ADS)
Szumska, A.; Budzanowski, M.; Kopeć, R.
2017-11-01
In its statement on tissue reactions approved on 21st April 2011, the International Commission on Radiological Protection (ICRP, 2012) reviewed its recommendation concerning the equivalent dose limit for the eye lens and reduced the dose limits for occupationally exposed persons to 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv. This limit was approved and written down in the new EURATOM (European Atomic Energy Community) directive 2013/59 and in the IAEA (International Atomic Energy Agency) BSS (Basic Safety Standard) of July 2014. For that reason, the necessity to monitor the eye lens may become more important than it was before. However, specially dedicated dosemeters for the dose quantity Hp(3) are using very rarely. Commonly use are only whole body personal dosemeters for the personal dose equivalent quantities Hp(10) worn on the trunk and ring dosemeters worn on finger to measure the quantity Hp(0.07). Therefore, in this work it was investigated whether dosemeters from routine use calibrated in terms of Hp(10) and Hp(0.07) and worn on thyroid collar and protective apron could deliver similar results like dedicated eye lens dosemeter worn close to the eyes. The results show that the best method if dedicated eye lens dosimeters is not used is to measure doses in terms of Hp(0.07) on the thyroid collar (Pearson product, r=0.85). Obtained results shows also importance of proper localization of eye lens dosimeter (close to the eye, from side of the X-ray source).
Eye lens dosimetry and the study on radiation cataract in interventional cardiologists.
Matsubara, Kosuke; Lertsuwunseri, Vorarit; Srimahachota, Suphot; Krisanachinda, Anchali; Tulvatana, Wasee; Khambhiphant, Bharkbhum; Sudchai, Waraporn; Rehani, Madan
2017-12-01
To determine the eye lens dose of the Interventional Cardiology (IC) personnel using optically stimulated luminescent dosimeter (OSLD) and the prevalence and risk of radiation - associated lens opacities in Thailand. 48 IC staff, with age- and sex- matches 37 unexposed controls obtained eye examines. Posterior lens change was graded using a modified Merriam-Focht technique by two independent ophthalmologists. Occupational exposure (mSv) was measured in 42 IC staff, using 2 OSLD badges place at inside lead apron and at collar. Annual eye lens doses (mSv) were also measured using 4 nanoDots OSL placed outside and inside lead glass eyewear. The prevalence of radiation-associated posterior lens opacities was 28.6% (2/7) for IC, 19.5% (8/41) for nurses, and 2.7% (1/37) for controls. The average and range of annual whole body effective dose, Hp(10), equivalent dose at skin of the neck, Hp(0.07) and equivalent dose at eye lens, Hp(3) were 0.80 (0.05-6.79), 5.88 (0.14-35.28), and 5.73 (0.14-33.20) mSv respectively. The annual average and range of eye lens dose using nano Dots OSL showed the outside lead glass eyewear on left and right sides as 8.06 (0.17-32.45), 3.55(0.06-8.04) mSv and inside left and right sides as 3.91(0.05-14.26) and 2.44(0.06-6.24) mSv respectively. Eye lens doses measured by OSLD badges and nano Dot dosimeter as Hp(10), Hp(0.07) and Hp(3). The eyes of the IC personnel were examined annually by two ophthalmologists for the prevalence of cataract induced by radiation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Esor, J.; Sudchai, W.; Monthonwattana, S.; Pungkun, V.; Intang, A.
2017-06-01
Based on a new occupational dose limit recommended by ICRP (2011), the annual dose limit for the lens of the eye for workers should be reduced from 150 mSv/y to 20 mSv/y averaged over 5 consecutive years in which no single year exceeding 50 mSv. This new dose limit directly affects radiologists and cardiologists whose work involves high radiation exposure over 20 mSv/y. Eye lens dosimetry (Hp(3)) has become increasingly important and should be evaluated directly based on dosimeters that are worn closely to the eye. Normally, Hp(3) dose algorithm was carried out by the combination of Hp(0.07) and Hp(10) values while dosimeters were calibrated on slab PMMA phantom. Recently, there were three reports from European Union that have shown the conversion coefficients from air kerma to Hp(3). These conversion coefficients carried out by ORAMED, PTB and CEA Saclay projects were performed by using a new cylindrical head phantom. In this study, various delivered doses were calculated using those three conversion coefficients while nanoDot, small OSL dosimeters, were used for Hp(3) measurement. These calibrations were performed with a standard X-ray generator at Secondary Standard Dosimetry Laboratory (SSDL). Delivered doses (Hp(3)) using those three conversion coefficients were compared with Hp(3) from nanoDot measurements. The results showed that percentage differences between delivered doses evaluated from the conversion coefficient of each project and Hp(3) doses evaluated from the nanoDots were found to be not exceeding -11.48 %, -8.85 % and -8.85 % for ORAMED, PTB and CEA Saclay project, respectively.
Monitoring the eye lens: which dose quantity is adequate?
NASA Astrophysics Data System (ADS)
Behrens, R.; Dietze, G.
2010-07-01
Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity Hp(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity Hp(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of Hp(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of Hp(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of Hp(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.
Monitoring the eye lens: which dose quantity is adequate?
Behrens, R; Dietze, G
2010-07-21
Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity H(p)(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity H(p)(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of H(p)(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of H(p)(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of H(p)(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.
The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.
Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke
2017-06-01
Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.
Ondo Meye, P; Schandorf, C; Amoako, J K; Manteaw, P O; Amoatey, E A; Adjei, D N
2017-12-01
An inter-comparison study was conducted to assess the capability of dosimetry systems of individual monitoring services (IMSs) in Gabon and Ghana to measure personal dose equivalent Hp(10) in photon fields. The performance indicators assessed were the lower limit of detection, linearity and uncertainty in measurement. Monthly and quarterly recording levels were proposed with corresponding values of 0.08 and 0.025 mSv, and 0.05 and 0.15 mSv for the TLD and OSL systems, respectively. The linearity dependence of the dosimetry systems was performed following the requirement given in the Standard IEC 62387 of the International Electrotechnical Commission (IEC). The results obtained for the two systems were satisfactory. The procedure followed for the uncertainty assessment is the one given in the IEC technical report TR62461. The maximum relative overall uncertainties, in absolute value, expressed in terms of Hp(10), for the TL dosimetry system Harshaw 6600, are 44. 35% for true doses below 0.40 mSv and 36.33% for true doses ≥0.40 mSv. For the OSL dosimetry system microStar, the maximum relative overall uncertainties, in absolute value, are 52.17% for true doses below 0.40 mSv and 37.43% for true doses ≥0.40 mSv. These results are in good agreement with the requirements for accuracy of the International Commission on Radiological protection. When expressing the uncertainties in terms of response, comparison with the IAEA requirements for overall accuracy showed that the uncertainty results were also acceptable. The values of Hp(10) directly measured by the two dosimetry systems showed a significant underestimation for the Harshaw 6600 system, and a slight overestimation for the microStar system. After correction for linearity of the measured doses, the two dosimetry systems gave better and comparable results. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Reducing operator radiation exposure during cardiac resynchronization therapy.
Brambilla, Marco; Occhetta, Eraldo; Ronconi, Martina; Plebani, Laura; Carriero, Alessandro; Marino, Paolo
2010-12-01
To quantify the reduction in equivalent dose at operator's hand that can be achieved by placement of a radiation-absorbing drape (RADPAD) during long-lasting cardiac resynchronization therapy (CRT) procedures. This is a prospective observational study that included 22 consecutive patients with drug-refractory heart failure who underwent implantation of a CRT device. The cases were randomly assigned to Group A (11 cases), performed without RADPAD, and to Group B (11 cases), performed using RADPAD. Dose equivalent at the examiner's hand was measured as H(p)(0.07) and as a time-adjusted H(p)(0.07) rate (mGy/min) with a direct reading dosimeter. The mean fluoroscopy time was 20.8 ± 7.7 min and the mean dose area product (DAP) was 118.6 ± 45.3 Gy cm(2). No significant differences were found between body mass index, fluoroscopy time, and DAP between patients examined with or without RADPAD. The correlation between the fluoroscopy time and the DAP was high (R(2) = 0.94, P < 0.001). Mean dose and dose rate measurement without the RADPAD at the finger and hand were H(p)(0.07) = 1.27 ± 0.47 mGy per procedure and H(p)(0.07) rate = 0.057 ± 0.011 mGy/min, respectively. The dosage was reduced with the RADPAD to H(p)(0.07) = 0.48 ± 0.20 (P < 0.05) and to H(p)(0.07) rate = 0.026 ± 0.008 (P < 0.001), respectively. A mean reduction of 54% in the equivalent dose rate to the operator's hand can be achieved with the use of RADPAD. The use of the RADPAD in CRT devices implantation will make unlikely the necessity of limiting the yearly number of implants for high volume operators.
Assessment of neutron dosemeters around standard sources and nuclear fissile objects.
Raimondi, N; Tournier, B; Groetz, J E; Piot, J; Riebler, E; Crovisier, P; Chambaudet, A; Cabanné, N
2002-01-01
In order to evaluate the neutron doses around nuclear fissile objects, a comparative study has been made on several neutron dosemeters: bubble dosemeters, etched-track detectors (CR-39) and 3He-filled proportional counters used as dose-rate meters. The measurements were made on the ambient and the personal dose equivalents H*(10) and Hp(10). Results showed that several bubble dosemeters should have been used due to a low reproducibility in the measurements. A strong correlation with the neutron energy was also found, with about a 30% underestimation of Hp(10) for neutrons from the PuBe source, and about a 9% overestimation for neutrons from the 252Cf source. Measurements of the nuclear fissile objects were made using the CR-39 and the dose-rate meters. The CR-39 led to an underestimation of 30% with respect to the neutron dose-rate meter measurements. In addition, the MCNP calculation code was used in the different configurations.
Budzanowski, Maciej; Kopeć, Renata; Obryk, Barbara; Olko, Paweł
2011-03-01
Individual dosimetry service based on thermoluminescence (TLD) detectors has started its activity at the Institute of Nuclear Physics (IFJ) in Krakow in 1965. In 2002, the new Laboratory of Individual and Environment Dosimetry (Polish acronym LADIS) was established and underwent the accreditation according to the EN-PN-ISO/IEC 17025 standard. Nowadays, the service is based on the worldwide known standard thermoluminescent detectors MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P), developed at IFJ, processed in automatic thermoluminescent DOSACUS or RE2000 (Rados Oy, Finland) readers. Laboratory provides individual monitoring in terms of personal dose equivalent H(p)(10) and H(p)(0.07) in photon and neutron fields, over the range from 0.1 mSv to 1 Sv, and environmental dosimetry in terms of air kerma K(a) over the range from 30 μGy to 1 Gy and also ambient dose equivalent H*(10) over the range from 30 μSv to 1 Sv. Dosimetric service is currently performed for ca. 3200 institutions from Poland and abroad, monitored on quarterly and monthly basis. The goal of this paper is to identify the main activities leading to the highest radiation exposures in Poland. The paper presents the results of statistical evaluation of ∼ 100,000 quarterly H(p)(10) and K(a) measurements performed between 2002 and 2009. Sixty-five per cent up to 90 % of all individual doses in Poland are on the level of natural radiation background. The dose levels between 0.1 and 5 mSv per quarter are the most frequent in nuclear medicine, veterinary and industrial radiography sectors.
Dose estimation to eye lens of industrial gamma radiography workers using the Monte Carlo method.
de Lima, Alexandre Roza; Hunt, John Graham; Da Silva, Francisco Cesar Augusto
2017-12-01
The ICRP Statement on Tissue Reactions (2011), based on epidemiological evidence, recommended a reduction for the eye lens equivalent dose limit from 150 to 20 mSv per year. This paper presents mainly the dose estimations received by industrial gamma radiography workers, during planned or accidental exposure to the eye lens, Hp(10) and effective dose. A Brazilian Visual Monte Carlo Dose Calculation program was used and two relevant scenarios were considered. For the planned exposure situation, twelve radiographic exposures per day for 250 days per year, which leads to a direct exposure of 10 h per year, were considered. The simulation was carried out using a 192 Ir source with 1.0 TBq of activity; a source/operator distance between 5 and 10 m and placed at heights of 0.02 m, 1 m and 2 m, and an exposure time of 12 s. Using a standard height of 1 m, the eye lens doses were estimated as being between 16.3 and 60.3 mGy per year. For the accidental exposure situation, the same radionuclide and activity were used, but in this case the doses were calculated with and without a collimator. The heights above ground considered were 1.0 m, 1.5 m and 2.0 m; the source/operator distance was 40 cm, and the exposure time 74 s. The eye lens doses at 1.5 m were 12.3 and 0.28 mGy without and with a collimator, respectively. The conclusions were that: (1) the estimated doses show that the 20 mSv annual limit for eye lens equivalent dose can directly impact industrial gamma radiography activities, mainly in industries with high number of radiographic exposures per year; (2) the risk of lens opacity has a low probability for a single accident, but depending on the number of accidental exposures and the dose levels found in planned exposures, the threshold dose can easily be exceeded during the professional career of an industrial radiography operator, and; (3) in a first approximation, Hp(10) can be used to estimate the equivalent dose to the eye lens.
Walsh, C; Gallagher, A; Dowling, A; Guiney, M; Ryan, J M; McEniff, N; O'Reilly, G
2015-01-01
Objective: In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Methods: Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Results: Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an “unprotected” eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma–area product and eye dose per procedure have been included in the analysis. Conclusion: Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. Advances in knowledge: We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting. PMID:25761211
Assessment of eye lens doses for workers during interventional radiology procedures.
Urboniene, A; Sadzeviciene, E; Ziliukas, J
2015-07-01
The assessment of eye lens doses for workers during interventional radiology (IR) procedures was performed using a new eye lens dosemeter. In parallel, the results of routine individual monitoring were analysed and compared with the results obtained from measurements with a new eye lens dosemeter. The eye lens doses were assessed using Hp(3) measured at the level of the eyes and were compared with Hp(10) measured with the whole-body dosemeter above the lead collar. The information about use of protective measures, the number of performed interventional procedures per month and their fluoroscopy time was also collected. The assessment of doses to the lens of the eye was done for 50 IR workers at 9 Lithuanian hospitals for the period of 2012-2013. If the use of lead glasses is not taken into account, the estimated maximum annual dose equivalent to the lens of the eye was 82 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Sandulache, Vlad C; Chen, Yunyun; Lee, Jaehyuk; Rubinstein, Ashley; Ramirez, Marc S; Skinner, Heath D; Walker, Christopher M; Williams, Michelle D; Tailor, Ramesh; Court, Laurence E; Bankson, James A; Lai, Stephen Y
2014-01-01
Ionizing radiation (IR) cytotoxicity is primarily mediated through reactive oxygen species (ROS). Since tumor cells neutralize ROS by utilizing reducing equivalents, we hypothesized that measurements of reducing potential using real-time hyperpolarized (HP) magnetic resonance spectroscopy (MRS) and spectroscopic imaging (MRSI) can serve as a surrogate marker of IR induced ROS. This hypothesis was tested in a pre-clinical model of anaplastic thyroid carcinoma (ATC), an aggressive head and neck malignancy. Human ATC cell lines were utilized to test IR effects on ROS and reducing potential in vitro and [1-¹³C] pyruvate HP-MRS/MRSI imaging of ATC orthotopic xenografts was used to study in vivo effects of IR. IR increased ATC intra-cellular ROS levels resulting in a corresponding decrease in reducing equivalent levels. Exogenous manipulation of cellular ROS and reducing equivalent levels altered ATC radiosensitivity in a predictable manner. Irradiation of ATC xenografts resulted in an acute drop in reducing potential measured using HP-MRS, reflecting the shunting of reducing equivalents towards ROS neutralization. Residual tumor tissue post irradiation demonstrated heterogeneous viability. We have adapted HP-MRS/MRSI to non-invasively measure IR mediated changes in tumor reducing potential in real time. Continued development of this technology could facilitate the development of an adaptive clinical algorithm based on real-time adjustments in IR dose and dose mapping.
Application of whole-body personal TL dosemeters in mixed field beta-gamma radiation.
Ciupek, K; Aksamit, D; Wołoszczuk, K
2014-11-01
Application of whole-body personal TL dosemeters based on a high-sensitivity LiF:Mg,Cu,P (MCP-N) in mixed field beta-gamma radiation has been characterised. The measurements were carried out with (90)Sr/(90)Y, (85)Kr and (137)Cs point sources to calculate the energy response and linearity of the TLD response in a dose range of 0.1-30 mSv. From the result, calibration curves were obtained, enabling the readout of individual dose equivalent Hp(10) from gamma radiation and Hp(0.07) from beta radiation in mixed field beta-gamma. Limitation of the methodology and its application are presented and discussed. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Occupational radiation exposure in nuclear medicine department in Kuwait
NASA Astrophysics Data System (ADS)
Alnaaimi, M.; Alkhorayef, M.; Omar, M.; Abughaith, N.; Alduaij, M.; Salahudin, T.; Alkandri, F.; Sulieman, A.; Bradley, D. A.
2017-11-01
Ionizing radiation exposure is associated with eye lens opacities and cataracts. Radiation workers with heavy workloads and poor protection measures are at risk for vision impairment or cataracts if suitable protection measures are not implemented. The aim of this study was to measure and evaluate the occupational radiation exposure in a nuclear medicine (NM) department. The annual average effective doses (Hp[10] and Hp[0.07]) were measured using calibrated thermos-luminescent dosimeters (TLDs; MCP-N [LiF:Mg,Cu,P]). Five categories of staff (hot lab staff, PET physicians, NM physicians, technologists, and nurses) were included. The average annual eye dose (Hp[3]) for NM staff, based on measurements for a typical yearly workload of >7000 patients, was 4.5 mSv. The annual whole body radiation (Hp[10]) and skin doses (Hp[0.07]) were 4.0 and 120 mSv, respectively. The measured Hp(3), Hp(10), and Hp(0.07) doses for all NM staff categories were below the dose limits described in ICRP 2014 in light of the current practice. The results provide baseline data for staff exposure in NM in Kuwait. Radiation dose optimization measures are recommended to reduce NM staff exposure to its minimal value.
Principi, S; Guardiola, C; Duch, M A; Ginjaume, M
2016-09-01
Recent studies highlight the fact that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens monitoring could be required for these workers. The recommended operational quantity for monitoring of eye lens exposure is the personal dose equivalent at 3 mm depth Hp(3) (ICRU 51). However, there are no available conversion coefficients in international standards, while in the literature coefficients have only been calculated for monoenergetic beams and for ISO 4037-1 X-ray qualities. The aim of this article is to provide air kerma to Hp(3) conversion coefficients for a cylindrical phantom made of ICRU-4 elements tissue-equivalent material for RQR radiation qualities (IEC-61267) from 40 to 120 kV and for angles of incidence from 0 to 180°, which are characteristic of medical workplace. Analytic calculations using interpolation techniques and Monte Carlo modelling have been compared. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omar, A; Marteinsdottir, M; Kadesjo, N
Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due tomore » protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.« less
Radiation dose to physicians’ eye lens during interventional radiology
NASA Astrophysics Data System (ADS)
Bahruddin, N. A.; Hashim, S.; Karim, M. K. A.; Sabarudin, A.; Ang, W. C.; Salehhon, N.; Bakar, K. A.
2016-03-01
The demand of interventional radiology has increased, leading to significant risk of radiation where eye lens dose assessment becomes a major concern. In this study, we investigate physicians' eye lens doses during interventional procedures. Measurement were made using TLD-100 (LiF: Mg, Ti) dosimeters and was recorded in equivalent dose at a depth of 0.07 mm, Hp(0.07). Annual Hp(0.07) and annual effective dose were estimated using workload estimation for a year and Von Boetticher algorithm. Our results showed the mean Hp(0.07) dose of 0.33 mSv and 0.20 mSv for left and right eye lens respectively. The highest estimated annual eye lens dose was 29.33 mSv per year, recorded on left eye lens during fistulogram procedure. Five physicians had exceeded 20 mSv dose limit as recommended by international commission of radiological protection (ICRP). It is suggested that frequent training and education on occupational radiation exposure are necessary to increase knowledge and awareness of the physicians’ thus reducing dose during the interventional procedure.
Dose conversion coefficients for photon exposure of the human eye lens.
Behrens, R; Dietze, G
2011-01-21
In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H(p)(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.
Dose conversion coefficients for photon exposure of the human eye lens
NASA Astrophysics Data System (ADS)
Behrens, R.; Dietze, G.
2011-01-01
In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.
Calibration of an eye lens dosemeter in terms of Hp(3) to be used in interventional radiology
NASA Astrophysics Data System (ADS)
Borges, F. L. S.; Guimarães, M. C.; Da Silva, T. A.; Nogueira Tavares, M. S.
2014-11-01
Recently, the International Commission on Radiological Protection has reviewed epidemiological evidences suggesting that there were tissue reaction effects in the eye lens below the previously considered absorbed dose threshold. A new statement related to the eye lens was issued that changed the absorbed dose threshold and reduced the dose limits for occupationally exposed persons. As consequence, some planned exposures require eye lens dosimetry and a debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to study the methodology for calibrating the EYE-DTM holder with a TLD-100H Harshaw chip detector and to determine its angular and energy dependences in terms of personal dose equivalent, Hp(3).
Dose conversion coefficients for electron exposure of the human eye lens
NASA Astrophysics Data System (ADS)
Behrens, R.; Dietze, G.; Zankl, M.
2009-07-01
Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity Hp(0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity Hp(3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0° and 45° are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.
Dose conversion coefficients for electron exposure of the human eye lens.
Behrens, R; Dietze, G; Zankl, M
2009-07-07
Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H(p)(0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H(p)(3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 degrees and 45 degrees are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.
Behrens, R
2012-09-01
The International Organization for Standardization (ISO) has issued a standard series on photon reference radiation qualities (ISO 4037). In this series, no conversion coefficients are contained for the quantity personal dose equivalent at a 3 mm depth, H(p)(3). In the past, for this quantity, a slab phantom was recommended as a calibration phantom; however, a cylinder phantom much better approximates the shape of a human head than a slab phantom. Therefore, in this work, the conversion coefficients from air kerma to H(p)(3) for the cylinder phantom are supplied for X- and gamma radiation qualities defined in ISO 4037.
A comparison of personal dose equivalent measurements made by personal dosemeters
NASA Astrophysics Data System (ADS)
Cechak, T.; Davidkova, J.; Kodl, O.; Novacek, P.; Papirnik, P.; Petrova, K.; Prasek, P.; Martincik, J.; Sochor, V.
2014-11-01
Individual monitoring services for external radiation were tested in the Czech Republic. The results of the tests show that they are dosimetry systems authorized and regularly tested in the Czech Republic having outliers for low energy region and angle of 50 degree and greater. With the highest probability, it can be stated that the processing equipment does not determine the angle of exposure reliably. These cases may have caused overestimations of Hp(10) in the special conditions occurring e.g. in interventional radiology and cardiology procedures.
Eye lens dose in interventional cardiology.
Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A
2015-07-01
The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Optically stimulated Al2O3:C luminescence dosimeters for teletherapy: Hp(10) performance evaluation.
Hashim, S; Musa, Y; Ghoshal, S K; Ahmad, N E; Hashim, I H; Yusop, M; Bradley, D A; Kadir, A B A
2018-05-01
The performance of optically stimulated luminescence dosimeters (OSLDs, Al 2 O 3 :C) was evaluated in terms of the operational quantity of H P (10) in Co-60 external beam teletherapy unit. The reproducibility, signal depletion, and dose linearity of each dosimeter was investigated. For ten repeated readouts, each dosimeter exposed to 50mSv was found to be reproducible below 1.9 ± 3% from the mean value, indicating good reader stability. Meanwhile, an average signal reduction of 0.5% per readout was found. The dose response revealed a good linearity within the dose range of 5-50mSv having nearly perfect regression line with R 2 equals 0.9992. The accuracy of the measured doses were evaluated in terms of operational quantity H P (10), wherein the trumpet curve method was used respecting the 1990 International Commission on Radiological Protection (ICRP) standard. The accuracy of the overall measurements from all dosimeters was discerned to be within the trumpet curve and devoid of outlier. It is established that the achieved OSL Al 2 O 3 :C dosimeters are greatly reliable for equivalent dose assessment. Copyright © 2018 Elsevier Ltd. All rights reserved.
Studies on new neutron-sensitive dosimeters using an optically stimulated luminescence technique
NASA Astrophysics Data System (ADS)
Kulkarni, M. S.; Luszik-Bhadra, M.; Behrens, R.; Muthe, K. P.; Rawat, N. S.; Gupta, S. K.; Sharma, D. N.
2011-07-01
The neutron response of detectors prepared using α-Al 2O 3:C phosphor developed using a melt processing technique and mixed with neutron converters was studied in monoenergetic neutron fields. The detector pellets were arranged in two different pairs: α-Al 2O 3:C + 6LiF/α-Al 2O 3:C + 7LiF and α-Al 2O 3:C + high-density polyethylene/α-Al 2O 3:C + Teflon, for neutron dosimetry using albedo and recoil proton techniques. The optically stimulated luminescence response of the Al 2O 3:C + 6,7LiF dosimeter to radiation from a 252Cf source was 0.21, in terms of personal dose equivalent Hp(10) and relative to radiation from a 137Cs source. This was comparable to results obtained with similar detectors prepared using commercially available α-Al 2O 3:C phosphor. The Hp(10) response of the α-Al 2O 3:C + 6,7LiF dosimeters was found to decrease by more than two orders of magnitude with increasing neutron energy, as expected for albedo dosimeters. The response of the α-Al 2O 3:C + high-density polyethylene/α-Al 2O 3:C + Teflon dosimeters was small, of the order of 1% to 2% in terms of Hp(10) and relative to radiation from a 137Cs source, for neutron energies greater than 1 MeV.
G.Garg, Hari; Mrabat, Hicham; Yu, Lunyin; Freeman, Craig; Li, Boyangzi; Zhang, Fuming; Linhardt, Robert J.; Hales, Charles A.
2010-01-01
Heparin (HP) inhibits the proliferation of bovine pulmonary artery smooth muscle cells (BPASMC's), among other cell types in vitro. In order to develop a potential therapeutic agent to reverse vascular remodeling, we are involved in deciphering the relationship between the native HP structure and its antiproliferative potency. We have previously reported the influence of the molecular size and the effects of various O-sulfo and N-acetyl groups of HP on growth-inhibitory activity. In this study, to understand the influence of carboxyl groups in the HP structure required for endogenous activity, a chemically modified derivative of native HP was prepared by converting the carboxyl groups of hexuronic acid residues in HP to primary hydroxyl groups. This modification procedure involves the treatment of HP with N-(3-dimethylaminopropyl)-N-ethylcarbodiimide followed by reduction with NaBH4 to yield carboxyl-reduced heparin (CR-HP). When compared to the antiproliferative potency of native HP on cultured BPASMC's at three dose levels (1, 10, and 100 μg/mL), the CR-HP showed significantly less potency at all the doses. These results suggest that hexuronic acid residues in both major and variable sequences in HP are essential for the antiproliferative properties of native HP. PMID:20399420
NASA Astrophysics Data System (ADS)
Kamwang, N.; Rungseesumran, T.; Saengchantr, D.; Monthonwattana, S.; Pungkun, V.
2017-06-01
The calibration of personal dosimeter to determine the quantities of the personal dose equivalent, Hp(d), is required to be placed on a suitable phantom in order to provide a reasonable approximation to the radiation backscattering properties as equivalent as part of body. The dosimeter which is worn on the trunk usually calibrated with slap phantom which recommended in ICRU 47 with dimension of 30 cm (w) x 30 cm (h) x 15 cm (t) PMMA slab phantom to achieve uniformity in calibration procedures, on the other hand the International Organization for Standardization (ISO), ISO 4037-3, proposed the ISO water slap phantom, with PMMA walls, same dimension but different wall thickness (front wall 2.5 mm and other side wall 10 mm thick) and fill with water. However, some laboratories are still calibrating a personal dosimeter in air in term of ambient dose equivalent, H*(d). This research study the effect of the scattering radiation in two type of those slap phantoms and in air, to calibrate two type of OSL (XA and LA) and electronic personal dosimeters. The X-ray and Cs-137 radiation field with the energy range from 33 to 662 keV were used. The results of this study will be discussed.
GEANT4 and PHITS simulations of the shielding of neutrons from the 252Cf source
NASA Astrophysics Data System (ADS)
Shin, Jae Won; Hong, Seung-Woo; Bak, Sang-In; Kim, Do Yoon; Kim, Chong Yeal
2014-09-01
Monte Carlo simulations are performed by using the GEANT4 and the PHITS for studying the neutron-shielding abilities of several materials, such as graphite, iron, polyethylene, NS-4-FR and KRAFTON-HB. As a neutron source, 252Cf is considered. For the Monte Carlo simulations by using the GEANT4, high precision (G4HP) models with the G4NDL 4.2 based on ENDF/B-VII data are used. For the simulations by using the PHITS, the JENDL-4.0 library is used. The neutron-dose-equivalent rates with or without five different shielding materials are estimated and compared with the experimental values. The differences between the shielding abilities calculated by using the GEANT4 with the G4NDL 4.2 and the PHITS with the JENDL-4.0 are found not to be significant for all the cases considered in this work. The neutron-dose-equivalent rates obtained by using the GEANT4 and the PHITS are compared with experimental data and other simulation results. Our neutron-dose-equivalent rates agree well with the experimental dose-equivalent rates, within 20% errors, except for polyethylene. For polyethylene, the discrepancies between our calculations and the experiments are less than 40%, as observed in other simulation results.
Fioroni, Federica; Grassi, Elisa; Giorgia, Cavatorta; Sara, Rubagotti; Piccagli, Vando; Filice, Angelina; Mostacci, Domiziano; Versari, Annibale; Iori, Mauro
2016-10-01
When handling Y-labelled and Lu-labelled radiopharmaceuticals, skin exposure is mainly due to β-particles. This study aimed to investigate the equivalent dose saving of the staff when changing from an essentially manual radiolabelling procedure to an automatic dose dispenser (ADD). The chemist and physician were asked to wear thermoluminescence dosimeters on their fingertips to evaluate the quantity of Hp(0.07) on the skin. Data collected were divided into two groups: before introducing ADD (no ADD) and after introducing ADD. For the chemist, the mean values (95th percentile) of Hp(0.07) for no ADD and ADD are 0.030 (0.099) and 0.019 (0.076) mSv/GBq, respectively, for Y, and 0.022 (0.037) and 0.007 (0.023) mSv/GBq, respectively, for Lu. The reduction for ADD was significant (t-test with P<0.05) for both isotopes. The relative differences before and after ADD collected for every finger were treated using the Wilcoxon test, proving a significantly higher reduction in extremity dose to each fingertip for Lu than for Y (P<0.05). For the medical staff, the mean values of Hp(0.07) (95th percentile) for no ADD and ADD are 0.021 (0.0762) and 0.0143 (0.0565) mSv/GBq, respectively, for Y, and 0.0011 (0.00196) and 0.0009 (0.00263) mSv/GBq, respectively, for Lu. The t-test provided a P-value less than 0.05 for both isotopes, making the difference between ADD and no ADD significant. ADD positively affects the dose saving of the chemist in handling both isotopes. For the medical staff not directly involved with the introduction of the ADD system, the analysis shows a learning curve of the workers over a 5-year period. Specific devices and procedures allow staff skin dose to be limited.
O'Connor, U; Gallagher, A; Malone, L; O'Reilly, G
2013-02-01
Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures. A new eye lens dosemeter (EYE-D(™), Radcard, Krakow, Poland) was used to measure the ERCP eye dose, H(p)(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out. The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma area product is also presented. Staff eye doses in ERCP have the potential to exceed the revised ICRP limit of 20 mSv per annum when an overcouch X-ray tube is used. The EYE-D dosemeter was found to be a convenient method for measuring lens dose. Eye doses in areas outside of radiology departments should be kept under review, particularly in light of the new ICRP eye dose limit. Occupational eye lens doses from ERCP procedures have been established using a new commercially available dedicated H(p)(3) dosemeter.
Mena-Serrano, A P; Parreiras, S O; do Nascimento, E M S; Borges, C P F; Berger, S B; Loguercio, A D; Reis, A
2015-01-01
In tooth whitening, the hydrogen peroxide (HP) diffuses in the enamel and dentin, reaching the pulp. This in vitro study aimed to quantify the penetration of HP in the pulp chamber in teeth submitted to bleaching agents of different concentrations of HP without calcium (HP 20% [20CF], HP 35% [35CF]) and with calcium (HP 20% [20CC], HP 35% [35CC]). Fifty human premolars were sectioned 3 mm from the cemento-enamel junction and the pulp tissue was removed. The teeth were divided into five groups according to treatment and with a control group (n=10). An acetate buffer solution was placed in the pulp chamber of all teeth. The control group was exposed only to distilled water, while the other groups were treated with a bleaching procedure, according to the manufacturer's recommendations. After treatment, the acetate buffer solution was transferred to a glass tube in which leuco-crystal violet and peroxidase solutions were added, resulting in a blue solution. The optical density of this blue solution was determined spectrophotometrically and converted into micrograms equivalent to the HP. Data were analyzed using analysis of variance and Tukey tests (α=0.05). The HP concentration did not affect the HP inside the pulp chamber, but the presence of calcium significantly reduced it (p<0.0001). The amount of HP that reaches the pulp chamber depends on the bleaching protocol and the product employed, and it seems to be less affected by HP concentration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magari, Hirohito; Shimizu, Yasuhito; Inada, Ken-ichi
2005-08-26
The effect of the selective COX-2 inhibitor, etodolac, on Helicobacter pylori (Hp)-associated stomach carcinogenesis was investigated in Mongolian gerbils (MGs). Hp-infected MGs were fed for 23 weeks with drinking water containing 10 ppm N-methyl-N-nitrosourea. They were then switched to distilled water and placed on a diet containing 5-30 mg/kg/day etodolac for 30 weeks. We found that etodolac dose-dependently inhibited the development of gastric cancer, and no cancer was detected at a dose of 30 mg/kg/day. Etodolac did not affect the extent of inflammatory cell infiltration or oxidative DNA damage, but it significantly inhibited mucosal cell proliferation and dose-dependently repressed themore » development of intestinal metaplasia in the stomachs of Hp-infected MGs. These results suggest that COX-2 is a key molecule in inflammation-mediated stomach carcinogenesis and that chemoprevention of stomach cancer should be possible by controlling COX-2 expression or activity.« less
Yusof, Fasihah Hanum; Ung, Ngie Min; Wong, Jeannie Hsiu Ding; Jong, Wei Loong; Ath, Vannyat; Phua, Vincent Chee Ee; Heng, Siew Ping; Ng, Kwan Hoong
2015-01-01
This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface doses were measured on a solid water phantom using the OSLD and compared against the Markus ionization chamber and Gafchromic EBT3 film measurements. The effect of incident beam angles on surface dose was also studied. The OSLD was subsequently used to measure surface dose during tangential breast radiotherapy treatments in a phantom study and in the clinical measurement of 10 patients. Surface dose to the treated breast or chest wall, and on the contralateral breast were measured. The WED of the OSLD was found to be at 0.4 mm. For surface dose measurement on a solid water phantom, the Markus ionization chamber measured 15.95% for 6 MV photon beam and 12.64% for 10 MV photon beam followed by EBT3 film (23.79% and 17.14%) and OSLD (37.77% and 25.38%). Surface dose increased with the increase of the incident beam angle. For phantom and patient breast surface dose measurement, the response of the OSLD was higher than EBT3 film. The in-vivo measurements were also compared with the treatment planning system predicted dose. The OSLD measured higher dose values compared to dose at the surface (Hp(0.0)) by a factor of 2.37 for 6 MV and 2.01 for 10 MV photon beams, respectively. The measurement of absorbed dose at the skin depth of 0.4 mm by the OSLD can still be a useful tool to assess radiation effects on the skin dermis layer. This knowledge can be used to prevent and manage potential acute skin reaction and late skin toxicity from radiotherapy treatments. PMID:26052690
No radiation protection reasons for restrictions on 14C urea breath tests in children.
Gunnarsson, M; Leide-Svegborn, S; Stenström, K; Skog, G; Nilsson, L-E; Hellborg, R; Mattsson, S
2002-12-01
Traditional (14)C urea breath tests are normally not used for younger children because the radiation exposure is unknown. High sensitivity accelerator mass spectrometry and an ultra-low amount (440 Bq) of (14)C urea were therefore used both to diagnose Helicobacter pylori (HP) infection in seven children, aged 3-6 years, and to make radiation dose estimates. The activity used was 125 times lower than the amount normally used for older children and 250 times lower than that used for adults. Results were compared with previously reported biokinetic and dosimetric data for adults and older children aged 7-14 years. (14)C activity concentrations in urine and exhaled air per unit administered activity for younger children (3-6 years) correspond well with those for older children (7-14 years). For a child aged 3-6 years who is HP negative, the urinary bladder wall receives the highest absorbed dose, 0.3 mGy MBq(-1). The effective dose is 0.1 mSv MBq(-1) for the 3-year-old child and 0.07 mSv MBq(-1) for the 6-year-old child. For two children, the 10 min and 20 min post-(14)C administration samples of exhaled air showed a significantly higher amount of (14)C activity than for the rest of the children, that is 6% and 19% of administered activity exhaled per hour compared with 0.3-0.9% (mean 0.5%) of administered activity exhaled per hour indicating that these two children that is were HP positive. For a 3-year-old HP positive child, absorbed dose to the urinary bladder wall was 0.3 mGy MBq(-1) and effective dose per unit of administered activity was 0.4 mSv MBq(-1). Using 55 kBq, which is a normal amount for older children when liquid scintillation counters are used for measurement, the effective dose will be approximately 6 micro Sv to a 3-year-old HP negative child and 20 microSv to a HP positive child. Thus there is no reason for restrictions on performing a normal (14)C urea breath test, even on young children.
Vano, E; Sanchez, R M; Fernandez, J M
2015-07-01
The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
10 CFR 20.1208 - Dose equivalent to an embryo/fetus.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20.1208 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Occupational Dose Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose...
Lacoste, V; Gressier, V
2007-01-01
The Institute for Radiological Protection and Nuclear Safety owns two facilities producing realistic mixed neutron-photon radiation fields, CANEL, an accelerator driven moderator modular device, and SIGMA, a graphite moderated americium-beryllium assembly. These fields are representative of some of those encountered at nuclear workplaces, and the corresponding facilities are designed and used for calibration of various instruments, such as survey meters, personal dosimeters or spectrometric devices. In the framework of the European project EVIDOS, irradiations of personal dosimeters were performed at CANEL and SIGMA. Monte Carlo calculations were performed to estimate the reference values of the personal dose equivalent at both facilities. The Hp(10) values were calculated for three different angular positions, 0 degrees, 45 degrees and 75 degrees, of an ICRU phantom located at the position of irradiation.
Omar, Artur; Marteinsdottir, Maria; Kadesjö, Nils; Fransson, Annette
2015-06-01
The International Commission on Radiological Protection (ICRP) has recommended that the occupational dose limit to the eye lens be substantially reduced. To ensure compliance with these recommendations, monitoring of the occupational eye lens dose is essential in certain hospital work environments. For assessment of the eye lens dose it is recommended to use a supplementary dosimeter placed at a position adjacent to the eye(s). Wearing a dosimeter at eye level can, however, be impractical and distributing and managing additional dosimeters over long periods of time is cumbersome and costly for large clinical sites. An attractive alternative is to utilize active personal dosimeters (APDs), which are routinely used by clinical staff for real-time monitoring of the personal dose equivalent rate (H(p)(10)). In this work, a formalism for the determination of eye lens dose from the response of such APD's worn on the chest is proposed and evaluated. The evaluation is based on both phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. The main results show that the eye lens dose to the primary operator and to the assisting clinical staff can be conservatively estimated from the APD response as D(eye)(conductor) = 2.0 APD chest and D(eye)(assisting) = 1.0 APD chest, respectively. However, care should be exercised for particularly short assisting staff and if radiation protection shields are misused. These concerns can be greatly mitigated if the clinical staff are provided with adequate radiation protection training.
Lee, S Y; Lee, K J
2001-04-01
To develop a personal optically stimulated luminescence (OSL) dosimetry system for mixed radiation fields using alpha-Al2O3:C, a discriminating badge filter system was designed by taking advantage of its optically stimulable properties and energy dependencies. This was done by designing a multi-element badge system for powder layered alpha-Al2O3:C material and an optical reader system based on high-intensity blue light-emitting diode (LED). The design of the multielement OSL dosimeter badge system developed allows the measurement of a personal dose equivalent value Hp(d) in mixed radiation fields of beta and gamma. Dosimetric properties of the personal OSL dosimeter badge system investigated here were the dose response, energy response and multi-readability. Based on the computational simulations and experiments of the proposed dosimeter design, it was demonstrated that a multi-element dosimeter system with an OSL technology based on alpha-Al2O3:C is suitable to obtain personal dose equivalent information in mixed radiation fields.
10 CFR 835.203 - Combining internal and external equivalent doses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.203 Combining internal and external equivalent doses. (a) The total effective dose...
ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONS.
Čemusová, Z; Ekendahl, D; Judas, L
2016-09-01
As workers in interventional radiology belong to one of the most occupationally exposed groups, methods for sufficiently accurate quantification of their external exposure are sought. The objective of the authors' experiment was to investigate the relations between eye lens dose and Hp(10), Hp(3) or Hp(0.07) values measured with a conventional whole-body personal thermoluminescence dosemeter (TLD). Conditions of occupational exposure during common interventional procedures were simulated in laboratory. An anthropomorphic phantom represented a physician. The TLDs were fixed to the phantom in different locations that are common for purposes of personal dosimetry. In order to monitor the dose at the eye lens level during the exposures, a special thermoluminescence eye dosemeter was fixed to the phantom's temple. Correlations between doses measured with the whole-body and the eye dosemeters were found. There are indications that personnel in interventional radiology do not need to be unconditionally equipped with additional eye dosemeters, especially if an appropriate whole-body dosimetry system has been already put into practice. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Horváth, A; Szenci, O; Nagy, K; Végh, L; Pribenszky, Cs
2016-03-01
The aim of the present study was to investigate the effect of applying sublethal stress treatment at room temperature, before cryopreservation (hydrostatic pressure (HP): 40MPa, 80min) of 34 boar ejaculate samples, on post-thawed motility and sow fertility. Sows (n=102) were randomly allocated into equal groups inseminated with HP-treated or untreated frozen-thawed semen. Sows were inseminated twice, 10h apart, with 6×10(9) spermatozoa per dose without oestrus synchronisation. Rates of non-return of oestrus and pregnancy, and total numbers of piglets and live piglets were significantly higher (P<0.05) in the HP-treated group. There was also a numerical, albeit non-significant (P>0.05), improvement in the farrowing rate in the HP-treated group. Although the number of live piglets per litter decreased approximately 15% in both groups by 42 days after farrowing, but this remained significantly higher in the HP-treated group. Although total and progressive sperm motility were significantly (P<0.001) higher in the HP-treated group, there were no significant differences (P>0.05) in these parameters between pregnant and non-pregnant sows in either group; thus motility can indicate, but not predict, improved fertility. In conclusion, HP treatment, with sperm cryopreservation, increases in vitro sperm motility and improves reproductive performance without adversely affecting the health of the piglets.
NASA Astrophysics Data System (ADS)
Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann
2017-04-01
An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus Hp(3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.
Computational analysis of the dose rates at JSI TRIGA reactor irradiation facilities.
Ambrožič, K; Žerovnik, G; Snoj, L
2017-12-01
The JSI TRIGA Mark II, IJS research reactor is equipped with numerous irradiation positions, where samples can be irradiated by neutrons and γ-rays. Irradiation position selection is based on its properties, such as physical size and accessibility, as well as neutron and γ-ray spectra, flux and dose intensities. This paper presents an overview on the neutron and γ-ray fluxes, spectra and dose intensities calculations using Monte Carlo MCNP software and ENDF/B-VII.0 nuclear data libraries. The dose-rates are presented in terms of ambient dose equivalents, air kerma, and silicon dose equivalent. At full reactor power the neutron ambient dose equivalent ranges from 5.5×10 3 Svh -1 to 6×10 6 Svh -1 , silicon dose equivalent from 6×10 2 Gy/h si to 3×10 5 Gy/h si , and neutron air kerma from 4.3×10 3 Gyh -1 to 2×10 5 Gyh -1 . Ratio of fast (1MeV
10 CFR 835.702 - Individual monitoring records.
Code of Federal Regulations, 2010 CFR
2010-01-01
... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...
10 CFR 835.702 - Individual monitoring records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...
10 CFR 835.702 - Individual monitoring records.
Code of Federal Regulations, 2014 CFR
2014-01-01
... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...
10 CFR 835.702 - Individual monitoring records.
Code of Federal Regulations, 2013 CFR
2013-01-01
... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...
10 CFR 835.702 - Individual monitoring records.
Code of Federal Regulations, 2012 CFR
2012-01-01
... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...
Is eye lens dosimetry needed in nuclear medicine?
Wrzesień, M; Królicki, L; Albiniak, Ł; Olszewski, J
2018-06-01
The exact level of exposure experienced by nuclear medicine personnel, whose work often requires performing manual procedures involving radioactive isotopes, is associated with the form of radiation source used. The variety of radionuclides and medical procedures, and the yearly increase in the number of patients, as well as the change of the individual dose limit for the lens of the eye from a value of 150 mSv yr -1 to 20 mSv yr -1 , mean that issues of eye lens routine dosimetry become interesting from the radiation protection point of view. This paper presents an analysis of the exposure of the eye lenses of nuclear medicine department personnel, as well as those of personnel in the facilities that produce radiopharmaceuticals for the purpose of diagnosis by positron emission tomography, from the viewpoint of the advisability of routine eye lens exposure monitoring, taking into account changes in the dose limit for the lens of the eye. The paper considers the two most commonly used radionuclides for diagnostic purposes 99m Tc, 18 F, and-for therapeutic purposes- 131 I. Dose measurements were made using thermoluminescent detectors. The estimated exposure analysis identifies the cases when the maximum annual value of the personal dose equivalent, in terms of Hp(3), exceeds threefold the new limit value (20 mSv yr -1 ). It is recommended that Hp(3) doses be routinely monitored in the group of radiopharmacists who label pharmaceuticals with the radionuclide 99m Tc and in chemists working in 18 F-FDG quality control departments in production units, where this is carried out manually.
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2010 CFR
2010-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2011 CFR
2011-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2013 CFR
2013-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2012 CFR
2012-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
10 CFR 60.136 - Preclosure controlled area.
Code of Federal Regulations, 2014 CFR
2014-01-01
... limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The eye dose equivalent shall not exceed 0.15 Sv (15 rem), and the shallow dose...
NASA Astrophysics Data System (ADS)
El-Jaby, Samy; Tomi, Leena; Sihver, Lembit; Sato, Tatsuhiko; Richardson, Richard B.; Lewis, Brent J.
2014-03-01
This paper describes a methodology for assessing the pre-mission exposure of space crew aboard the International Space Station (ISS) in terms of an effective dose equivalent. In this approach, the PHITS Monte Carlo code was used to assess the particle transport of galactic cosmic radiation (GCR) and trapped radiation for solar maximum and minimum conditions through an aluminum shield thickness. From these predicted spectra, and using fluence-to-dose conversion factors, a scaling ratio of the effective dose equivalent rate to the ICRU ambient dose equivalent rate at a 10 mm depth was determined. Only contributions from secondary neutrons, protons, and alpha particles were considered in this analysis. Measurements made with a tissue equivalent proportional counter (TEPC) located at Service Module panel 327, as captured through a semi-empirical correlation in the ISSCREM code, where then scaled using this conversion factor for prediction of the effective dose equivalent. This analysis shows that at this location within the service module, the total effective dose equivalent is 10-30% less than the total TEPC dose equivalent. Approximately 75-85% of the effective dose equivalent is derived from the GCR. This methodology provides an opportunity for pre-flight predictions of the effective dose equivalent and therefore offers a means to assess the health risks of radiation exposure on ISS flight crew.
Kim, Kyoung-Ok; Park, HyunJin; Chun, Mison; Kim, Hyun-Sook
2014-09-01
We hypothesized that a high-protein diet and/or resveratrol supplementation will improve acute inflammatory responses in rats after receiving experimental abdominal radiation treatment (ART). Based on our previous study, the period of 10 days after ART was used as an acute inflammation model. Rats were exposed to a radiation dose of 17.5 Gy and were supplied with a control (C), 30% high-protein diet (HP), resveratrol supplementation (RES), or HP with RES diet ([HP+RES]). At day 10 after ART, we measured profiles of lipids, proteins, and immune cells in blood. The levels of clusters of differentiating 4(+) (CD4(+)) cells and regulatory T cells, serum proinflammatory cytokines, and 8-hydroxy-2'-deoxyguanosine (8-OHdG) in urine were also measured. ART caused significant disturbances of lipid profiles by increasing triglyceride (TG) and low-density lipoprotein cholesterol (LDL-C), and decreasing high-density lipoprotein cholesterol. The proinflammatroy cytokine levels were also increased by ART. All the experimental diets (HP, RES, and [HP+RES]) significantly decreased levels of TG, monocytes, proinflammatory cytokines, and 8-OHdG, whereas the platelet counts were increased. In addition, the HP and [HP+RES] diets decreased the concentrations of plasma LDL-C and total cholesterol. Also, the HP and RES diets decreased regulatory T cells compared with those of the control diet in ART group. Further, the HP diet led to a significant recovery of white blood cell counts, as well as increased percentages of lymphocyte and decreased percentages of neutrophils. In summary, RES appeared to be significantly effective in minimizing radiation-induced damage to lipid metabolism and immune responses. Our study also demonstrated the importance of dietary protein intake in recovering from acute inflammation by radiation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, W.F.; Molteni, A.; Ts'ao, C.H.
The angiotensin converting enzyme inhibitor captopril ameliorates radiation-induced pulmonary endothelial dysfunction in rats. The present study determined whether captopril also reduces collagen (hydroxyproline) accumulation in the lungs of rats sacrificed 2 months after a range of single doses (0-30 Gy) of 60Co gamma rays to the right hemithorax. Captopril was administered in the feed at a regimen of 0, 25, or 50 mg/kg/day continuously after irradiation. Mast cell counts also were obtained from lungs of all animals exposed to 30 Gy. In rats receiving no captopril, there was a radiation dose-dependent increase in right lung hydroxyproline (HP) content and inmore » HP concentration per g wet weight. Captopril produced a drug dose-dependent suppression in this radiation-induced HP accumulation. At a dose of 50 mg/kg/d, captopril reduced the slope of the radiation dose response curve for lung HP content by a factor of 1.7, and completely prevented the increase in HP concentration. At an isoeffect level of 550 micrograms HP per right superior lobe, this dose of captopril exhibited a DRF of 1.7 +/- 0.2. In rats exposed to 30 Gy, moreover, the number of mast cells per mm2 of alveolar cross-sectional surface area decreased from 105 +/- 8 to 100 +/- 7 and 59 +/- 5 in the groups given 0, 25 or 50 mg/kg/d of captopril, respectively, (vs none in sham-irradiated rats). These data are the first to demonstrate that the ACE inhibitor captopril might provide a novel intervention in the pathogenesis of radiation fibrosis.« less
Devi, Savita; Ansari, Suhail A; Vadivelu, Jamuna; Mégraud, Francis; Tenguria, Shivendra; Ahmed, Niyaz
2014-02-01
The envisaged roles and partly understood functional properties of Helicobacter pylori protein HP0986 are significant in the context of proinflammatory and or proapoptotic activities, the two important facilitators of pathogen survival and persistence. In addition, sequence analysis of this gene predicts a restriction endonuclease function which remained unknown thus far. To evaluate the role of HP0986 in gastric inflammation, we studied its expression profile using a large number of clinical isolates but a limited number of biopsies and patient sera. Also, we studied antigenic role of HP0986 in altering cytokine responses of human gastric epithelial (AGS) cells including its interaction with and localization within the AGS cells. For in vitro expression study of HP0986, 110 H. pylori clinical isolates were cultured from patients with functional dyspepsia. For expression analysis by qRT PCR of HP0986, 10 gastric biopsy specimens were studied. HP0986 was also used to detect antibodies in patient sera. AGS cells were incubated with recombinant HP0986 to determine cytokine response and NF-κB activation. Transient transfection with HP0986 cloned in pEGFPN1 was used to study its subcellular localization or homing in AGS cells. Out of 110 cultured H. pylori strains, 34 (31%) were positive for HP0986 and this observation was correlated with in vitro expression profiles. HP0986 mRNA was detected in 7 of the 10 biopsy specimens. Further, HP0986 induced IL-8 secretion in gastric epithelial cells in a dose and time-dependent manner via NF-κB pathway. Serum antibodies against HP0986 were positively associated with H. pylori positive patients. Transient transfection of AGS cells revealed both cytoplasmic and nuclear localization of HP0986. HP0986 was moderately prevalent in clinical isolates and its expression profile in cultures and gastric biopsies points to its being naturally expressed. Collective observations including the induction of IL-8 via TNFR1 and NF-κB, subcellular localization, and seropositivity data point to a significant role of HP0986 in gastroduodenal inflammation. We propose to name the HP0986 gene/protein as 'TNFR1 interacting endonuclease A (TieA or tieA)'. © 2013 John Wiley & Sons Ltd.
Goldstein, David L; Plaga, Kimberly
2002-10-01
We compared the renal responses of rats on three diet regimens. Rats received either 8% protein food (low-protein, LP) for 10 weeks following weaning, 8% protein for 9 weeks followed by 1 week on 30% protein (short-term high-protein, SHP), or 30% protein for 10 weeks (high-protein, HP). Kidneys from HP rats were enlarged by approximately 50%, or 20% when corrected for body mass. Most of this hypertrophy resulted from enlargement of the inner stripe of the outer medulla, site of the thick ascending limbs (TAL), and TAL from HP rats were larger in diameter. SHP rats had TAL diameters similar to HP rats, but changes in renal mass or height of renal zones did not reach statistical significance. The activity of adenylyl cyclase (AC) in TAL, measured from the accumulation of cAMP in isolated tubules, increased with dose of both arginine vasopressin (AVP) and glucagon in all rats. However, HP rats had significantly higher hormone-induced AC activity than LP or SHP rats, which were not different from each other. Our results suggest that tubule hypertrophy may precede up-regulation of hormone-sensitive AC activity during the progression of renal response to elevated dietary protein.
PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fallu-Labruyere, A.; Micou, C.; Schulcz, F.
PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, havemore » emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)« less
Moslehi, Amir; Raisali, Gholamreza
2018-07-01
The response of a microdosimeter for neutrons above 14 MeV is investigated. The mean quality factors and dose-equivalents are determined using lineal energy distributions calculated by Monte Carlo simulations (Geant4 toolkit). From 14 MeV to 5 GeV, the mean quality factors were found to vary between 6.00 and 9.30 and the dose-equivalents were in agreement with the true ambient dose-equivalent at the depth of 10 mm inside the ICRU sphere, H * (10). An energy-independent dose-equivalent response around a median value of 0.86 within 22% uncertainty was obtained. Therefore, the microdosimeter is appropriate for dose-equivalent measurement of high-energy neutrons. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sun, R K
1990-12-01
To investigate the radiation effect of neutrons near the Advanced Light Source (ALS) at Lawrence Berkeley Laboratory (LBL) with respect to the neutron dose equivalents in nearby occupied areas and at the site boundary, the neutron transport code MORSE, from Oak Ridge National Laboratory (ORNL), was used. These dose equivalents result from both skyshine neutrons transported by air scattering and direct neutrons penetrating the shielding. The ALS neutron sources are a 50-MeV linear accelerator and its transfer line, a 1.5-GeV booster, a beam extraction line, and a 1.9-GeV storage ring. The most conservative total occupational-dose-equivalent rate in the center of the ALS mezzanine, 39 m from the ALS center, was found to be 1.14 X 10(-3) Sv y-1 per 2000-h "occupational" year, and the total environmental-dose-equivalent rate at the ALS boundary, 125 m from the ALS center, was found to be 3.02 X 10(-4) Sv y-1 per 8760-h calendar year. More realistic dose-equivalent rates, using the nominal (expected) storage-ring current, were calculated to be 1.0 X 10(-4) Sv y-1 and 2.65 X 10(-5) Sv y-1 occupational year and calendar year, respectively, which are much lower than the DOE reporting levels.
Yu, Xiuling; Zhou, Zhi; Cao, Zhen; Wu, Jiajun; Zhang, Zhongqiu; Xu, Baiwan; Wang, Chuanbin; Hu, Dongmei; Deng, Xiaoyu; Han, Wei; Gu, Xiaoxue; Zhang, Shuo; Li, Xiaoxia; Wang, Baoyue; Zhai, Xinyan; Tian, Kegong
2015-05-01
The safety and efficacy of the JXA1-R vaccine, an attenuated strain of highly pathogenic porcine reproductive and respiratory syndrome virus (HP-PRRSV), were examined using an intramuscular challenge model in piglets. The JXA1-R vaccine was obtained by passing HP-PRRSV JXA1 through Marc-145 cells (82nd passage). Genomic sequence comparisons showed that strain JXA1-R and its parental strain, JXA1, differ by 47 amino acids, and most of these differences are scattered throughout the PRRSV genome. Four-week-old PRRSV-free piglets were inoculated intramuscularly with JXA1-R vaccine (10(3.0), 10(4.0), 10(5.0), 10(6.0), and 10(7.0) 50% tissue culture infective doses [TCID50]/ml for groups 1 to 5, respectively) and then challenged intramuscularly with the 5th passage virus of JXA1 virus (JXA1-F5, 3 ml × 10(4.5) TCID50/ml) 28 days after inoculation. The humoral immune response, swine growth, clinical signs, and differential organ lesions were monitored. The results showed that all vaccinated piglets had a perceptible humoral immune response to vaccination after day 7, which then promptly increased, almost reaching the maximum sample/positive (S/P) ratio value at 28 days postimmunization. Viremia detection indicated that the viral replication levels of the challenge virus in the immunized groups (immunization doses ≥10(4.0)/ml) were significantly lower than that of the virus-challenged unvaccinated control group. Piglets in groups 2 to 5 were effectively protected against lethal HP-PRRSV infection and did not show any obvious changes in body temperature or clinical signs of disease at any point during the experiment. However, two of five piglets in group 1 showed mild pathological lesions and transitory high fever. These results suggest that JXA1-R (TCID50/ml ≥10(4.0)) is sufficiently attenuated and can provide effective protection against the lethal wild-type HP-PRRSV. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Howell, Rebecca M; Burgett, Eric A; Isaacs, Daniel; Price Hedrick, Samantha G; Reilly, Michael P; Rankine, Leith J; Grantham, Kevin K; Perkins, Stephanie; Klein, Eric E
2016-05-01
To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth-dose data to in-air H* (10) values. For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10(6) to 1.04 × 10(7) n/cm(2)/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2012 CFR
2012-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2014 CFR
2014-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2011 CFR
2011-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2013 CFR
2013-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
10 CFR 72.106 - Controlled area of an ISFSI or MRS.
Code of Federal Regulations, 2010 CFR
2010-01-01
... controlled area may not receive from any design basis accident the more limiting of a total effective dose equivalent of 0.05 Sv (5 rem), or the sum of the deep-dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose...
Code of Federal Regulations, 2014 CFR
2014-01-01
...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...
Code of Federal Regulations, 2011 CFR
2011-01-01
...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...
Code of Federal Regulations, 2012 CFR
2012-01-01
...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...
Code of Federal Regulations, 2010 CFR
2010-01-01
...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...
Code of Federal Regulations, 2013 CFR
2013-01-01
...) a committed effective dose equivalent of 5 rems (stochastic ALI) or (2) a committed dose equivalent of 50 rems to an organ or tissue (non-stochastic ALI). The stochastic ALIs were derived to result in... equivalent to the whole body of 5 rems. The derivation includes multiplying the committed dose equivalent to...
10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...
10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...
10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...
10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...
10 CFR 835.205 - Determination of compliance for non-uniform exposure of the skin.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 100 cm 2 or more. The non-uniform equivalent dose received during the year shall be averaged over the... irradiated is 10 cm 2 or more, but is less than 100 cm 2. The non-uniform equivalent dose (H) to the... less than 0.1 be used. (3) Area of skin irradiated is less than 10 cm 2. The non-uniform equivalent...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2010 CFR
2010-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2010-01-01 2010-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2014 CFR
2014-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2014-01-01 2014-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2012 CFR
2012-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2012-01-01 2012-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2013 CFR
2013-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2013-01-01 2013-01-01 false Occupational dose limits for general employees. 835.202...
10 CFR 835.202 - Occupational dose limits for general employees.
Code of Federal Regulations, 2011 CFR
2011-01-01
... tissue other than the skin or the lens of the eye of 50 rems (0.5 Sv); (3) An equivalent dose to the lens of the eye of 15 rems (0.15 Sv); and (4) The sum of the equivalent dose to the skin or to any... 10 Energy 4 2011-01-01 2011-01-01 false Occupational dose limits for general employees. 835.202...
Code of Federal Regulations, 2014 CFR
2014-01-01
... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...
Code of Federal Regulations, 2012 CFR
2012-01-01
... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...
Code of Federal Regulations, 2011 CFR
2011-01-01
... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...
Code of Federal Regulations, 2013 CFR
2013-01-01
... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...
Code of Federal Regulations, 2010 CFR
2010-01-01
... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...
Sohrabi, Mehdi; Hakimi, Amir
2018-02-01
Photoneutron (PN) dosimetry in fast, epithermal and thermal energy ranges originated from the beam and albedo neutrons in high-energy X-ray medical accelerators is highly important from scientific, technical, radiation protection and medical physics points of view. Detailed dose equivalents in the fast, epithermal and thermal PN energy ranges in air up to 2m as well as at 35 positions from the central axis of 12 cross sections of the phantom at different depths were determined in 18MV X-ray beams of a Siemens ONCOR accelerator. A novel dosimetry method based on polycarbonate track dosimeters (PCTD)/ 10 B (with/without cadmium cover) was used to determine and separate different PN dose equivalents in air and in a multilayer polyethylene phantom. Dose equivalent distributions of PNs, as originated from the main beam and/or albedo PNs, on cross-plane, in-plane and diagonal axes in 10cm×10cm fields are reported. PN dose equivalent distributions on the 3 axes have their maxima at the isocenter. Epithermal and thermal PN depth dose equivalent distributions in the phantom for different positions studied peak at ∼3cm depth. The neutron dosimeters used for the first time in such studies are highly effective for separating dose equivalents of PNs in the studied energy ranges (beam and/or albedo). The PN dose equivalent data matrix made available in this paper is highly essential for detailed patient dosimetry in general and for estimating secondary cancer risks in particular. Copyright © 2017. Published by Elsevier GmbH.
Manyam, Bala V; Dhanasekaran, Muralikrishnan; Hare, Theodore A
2004-02-01
HP-200, which contains Mucuna pruriens endocarp, has been shown to be effective in the treatment of Parkinson's disease. Mucuna pruriens endocarp has also been shown to be more effective compared to synthetic levodopa in an animal model of Parkinson's disease. The present study was designed to elucidate the long-term effect of Mucuna pruriens endocarp in HP-200 on monoaminergic neurotransmitters and its metabolite in various regions of the rat brain. HP-200 at a dose of 2.5, 5.0 or 10.0 g/kg/day was mixed with rat chow and fed daily ad lib to Sprague-Dawley rats (n = 6 for each group) for 52 weeks. Controls (n = 6) received no drug. Random assignment was made for doses and control. The rats were sacrificed at the end of 52 weeks and the neurotransmitters were analyzed in the cortex, hippocampus, substantia nigra and striatum. Oral administration of Mucuna pruriens endocarp in the form of HP-200 had a significant effect on dopamine content in the cortex with no significant effect on levodopa, norepinephrine or dopamine, serotonin, and their metabolites- HVA, DOPAC and 5-HIAA in the nigrostriatal tract. The failure of Mucuna pruriens endocarp to significantly affect dopamine metabolism in the striatonigral tract along with its ability to improve Parkinsonian symptoms in the 6-hydorxydopamine animal model and humans may suggest that its antiparkinson effect may be due to components other than levodopa or that it has an levodopa enhancing effect. Copyright 2004 John Wiley & Sons, Ltd. Copyright 2004 John Wiley & Sons, Ltd.
Biomarkers of polycyclic aromatic hydrocarbon exposure in European coke oven workers.
Talaska, Glenn; Thoroman, Jeff; Schuman, Brenda; Käfferlein, Heiko Udo
2014-12-01
Biomonitoring is an excellent method for capturing the results of all exposures, regardless of route. Coke oven workers include certain groups that have the potential for high exposure to polycyclic aromatic hydrocarbons (PAH) and other materials. Biomarkers of exposure to these agents include PAH metabolites as markers of internal dose and carcinogen-DNA adducts as measure of effective dose. The purpose of this study was to determine the levels of these biomarkers in persons with different job duties in a modern coke oven plant. We report that the mean levels of 1-hydroxypyrene (1HP) and carcinogen DNA adducts in the exfoliated urothelial cells of coke oven workers are increased the closer a group of workers is to the ovens and highest in the top oven workers with average 1HP level of 11.6 μg/l and 22 adducts per 10(9) unadducted nucleotides. Both 1HP and carcinogen DNA adduct levels increased in supervisors, area workers, side oven workers, top and side oven workers, and top oven workers, respectively. These data are the first to demonstrate an increase in target organ genotoxicity in coke oven workers and a relationship with other biomarkers. Future studies will determine the identity of the DNA adducts, their correlation with 1HP levels and the relationship between levels in individual workers. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
van Haaren, Paul; Claassen-Janssen, Fiere; van de Sande, Ingrid; Boersma, Liesbeth; van der Sangen, Maurice; Hurkmans, Coen
2017-08-01
Voluntary moderate deep inspiration breath hold (vmDIBH) in left-sided breast cancer radiotherapy reduces cardiac dose. The aim of this study was to investigate heart position variability in vmDIBH using CBCT and to compare this variability with differences in heart position between vmDIBH and free breathing (FB). For 50 patients initial heart position with respect to the field edge (HP-FE) was measured on a vmDIBH planning CT scan. Breath-hold was monitored using an in-house developed vertical plastic stick. On pre-treatment CBCT scans, heart position variability with respect to the field edge (Δ HP-FE ) was measured, reflecting heart position variability when using an offline correction protocol. After registering the CBCT scan to the planning CT, heart position variability with respect to the chest wall (Δ HP-CW ) was measured, reflecting heart position variability when using an online correction protocol. As a control group, vmDIBH and FB computed tomography (CT) scans were acquired for 30 patients and registering both scans on the chest wall. For 34 out of 50 patients, the average HP-FE and HP-CW increased over the treatment course in comparison to the planning CT. Averaged over all patients and all treatment fractions, the Δ HP-FE and the Δ HP-CW was 0.8±4.2mm (range -9.4-+10.6mm) and 1.0±4.4mm (range -8.3-+10.4mm) respectively. The average gain in heart to chest wall distance was 11.8±4.6mm when using vmDIBH instead of FB. In conclusion, substantial variability in heart position using vmDIBH was observed during the treatment course. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Demonstration of electronic design automation flow for massively parallel e-beam lithography
NASA Astrophysics Data System (ADS)
Brandt, Pieter; Belledent, Jérôme; Tranquillin, Céline; Figueiro, Thiago; Meunier, Stéfanie; Bayle, Sébastien; Fay, Aurélien; Milléquant, Matthieu; Icard, Beatrice; Wieland, Marco
2014-07-01
For proximity effect correction in 5 keV e-beam lithography, three elementary building blocks exist: dose modulation, geometry (size) modulation, and background dose addition. Combinations of these three methods are quantitatively compared in terms of throughput impact and process window (PW). In addition, overexposure in combination with negative bias results in PW enhancement at the cost of throughput. In proximity effect correction by over exposure (PEC-OE), the entire layout is set to fixed dose and geometry sizes are adjusted. In PEC-dose to size (DTS) both dose and geometry sizes are locally optimized. In PEC-background (BG), a background is added to correct the long-range part of the point spread function. In single e-beam tools (Gaussian or Shaped-beam), throughput heavily depends on the number of shots. In raster scan tools such as MAPPER Lithography's FLX 1200 (MATRIX platform) this is not the case and instead of pattern density, the maximum local dose on the wafer is limiting throughput. The smallest considered half-pitch is 28 nm, which may be considered the 14-nm node for Metal-1 and the 10-nm node for the Via-1 layer, achieved in a single exposure with e-beam lithography. For typical 28-nm-hp Metal-1 layouts, it was shown that dose latitudes (size of process window) of around 10% are realizable with available PEC methods. For 28-nm-hp Via-1 layouts this is even higher at 14% and up. When the layouts do not reach the highest densities (up to 10∶1 in this study), PEC-BG and PEC-OE provide the capability to trade throughput for dose latitude. At the highest densities, PEC-DTS is required for proximity correction, as this method adjusts both geometry edges and doses and will reduce the dose at the densest areas. For 28-nm-hp lines critical dimension (CD), hole&dot (CD) and line ends (edge placement error), the data path errors are typically 0.9, 1.0 and 0.7 nm (3σ) and below, respectively. There is not a clear data path performance difference between the investigated PEC methods. After the simulations, the methods were successfully validated in exposures on a MAPPER pre-alpha tool. A 28-nm half pitch Metal-1 and Via-1 layouts show good performance in resist that coincide with the simulation result. Exposures of soft-edge stitched layouts show that beam-to-beam position errors up to ±7 nm specified for FLX 1200 show no noticeable impact on CD. The research leading to these results has been performed in the frame of the industrial collaborative consortium IMAGINE.
Samad, Noreen; Haleem, Darakhshan Jabeen
2017-08-01
Tardive dyskinesia (TD) is associated with the use of antipsychotic drugs such as D2 antagonist haloperidol (HP). The chronic use of HP is involved in the causation of free radicals and/or oxidative stress. In view of the nootropic, anti-anxiety, anti-inflammatory-like effects of rice bran oil (RBO) in a variety of investigations, we assessed the protective properties of RBO on HP-induced TD and neurochemical alteration. Rats treated with HP orally at a dose of 0.2 mg/kg/day for a period of 5 weeks developed VCMs which increased progressively as the treatment continued for 5 weeks. Co-administration of RBO by oral tubes at a dose of 0.4 ml/day prevented the induction of HP-induced VCMs. Repeated administration of HP increases the turnover of dopamine metabolism in the striatum. Conversely animals treated with HP + RBO decrease the metabolism of DA than water + HP treated animals. Striatal, malondieldehyde (MDA), hydrogen peroxide (H 2 O 2 ) and antioxidant enzyme superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPx) were also determined. It is suggested that beneficial role of RBO in attenuation of HP-induced TD. The results therefore recommended that supplementation of RBO may be useful in the HP-induced TD. The findings have also potential implication in the treatment of schizophrenia and motor disorders.
Can the Equivalent Sphere Model Approximate Organ Doses in Space?
NASA Technical Reports Server (NTRS)
Lin, Zi-Wei
2007-01-01
For space radiation protection it is often useful to calculate dose or dose,equivalent in blood forming organs (BFO). It has been customary to use a 5cm equivalent sphere to. simulate the BFO dose. However, many previous studies have concluded that a 5cm sphere gives very different dose values from the exact BFO values. One study [1] . concludes that a 9 cm sphere is a reasonable approximation for BFO'doses in solar particle event environments. In this study we use a deterministic radiation transport [2] to investigate the reason behind these observations and to extend earlier studies. We take different space radiation environments, including seven galactic cosmic ray environments and six large solar particle events, and calculate the dose and dose equivalent in the skin, eyes and BFO using their thickness distribution functions from the CAM (Computerized Anatomical Man) model [3] The organ doses have been evaluated with a water or aluminum shielding of an areal density from 0 to 20 g/sq cm. We then compare with results from the equivalent sphere model and determine in which cases and at what radius parameters the equivalent sphere model is a reasonable approximation. Furthermore, we address why the equivalent sphere model is not a good approximation in some cases. For solar particle events, we find that the radius parameters for the organ dose equivalent increase significantly with the shielding thickness, and the model works marginally for BFO but is unacceptable for the eye or the skin. For galactic cosmic rays environments, the equivalent sphere model with an organ-specific constant radius parameter works well for the BFO dose equivalent, marginally well for the BFO dose and the dose equivalent of the eye or the skin, but is unacceptable for the dose of the eye or the skin. The ranges of the radius parameters are also being investigated, and the BFO radius parameters are found to be significantly, larger than 5 cm in all cases, consistent with the conclusion of an earlier study [I]. The radius parameters for the dose equivalent in GCR environments are approximately between 10 and I I cm for the BFO, 3.7 to 4.8 cm for the eye, and 3.5 to 5.6 cm for the skin; while the radius parameters are between 10 and 13 cm for the BFO dose.
Apipunyasopon, Lukkana; Srisatit, Somyot; Phaisangittisakul, Nakorn
2013-09-06
The purpose of the study was to investigate the use of the equivalent square formula for determining the surface dose from a rectangular photon beam. A 6 MV therapeutic photon beam delivered from a Varian Clinac 23EX medical linear accelerator was modeled using the EGS4nrc Monte Carlo simulation package. It was then used to calculate the dose in the build-up region from both square and rectangular fields. The field patterns were defined by various settings of the X- and Y-collimator jaw ranging from 5 to 20 cm. Dose measurements were performed using a thermoluminescence dosimeter and a Markus parallel-plate ionization chamber on the four square fields (5 × 5, 10 × 10, 15 × 15, and 20 × 20 cm2). The surface dose was acquired by extrapolating the build-up doses to the surface. An equivalent square for a rectangular field was determined using the area-to-perimeter formula, and the surface dose of the equivalent square was estimated using the square-field data. The surface dose of square field increased linearly from approximately 10% to 28% as the side of the square field increased from 5 to 20 cm. The influence of collimator exchange on the surface dose was found to be not significant. The difference in the percentage surface dose of the rectangular field compared to that of the relevant equivalent square was insignificant and can be clinically neglected. The use of the area-to-perimeter formula for an equivalent square field can provide a clinically acceptable surface dose estimation for a rectangular field from a 6 MV therapy photon beam.
An Explanation of the Superior Performance IQs of Deaf Children of Deaf Parents.
ERIC Educational Resources Information Center
Braden, Jeffery P.
1987-01-01
Differences in performance IQs between deaf children of hearing parents (HP), deaf children of deaf parents (DP), and hearing children (HC) may be a result of differences in speed of information processing. DP adolescents were found to have faster reaction and movement times than HP or HC subjects along with equivalent IQs. (Author/VW)
NASA Astrophysics Data System (ADS)
Fujibuchi, Toshioh; Kodaira, Satoshi; Sawaguchi, Fumiya; Abe, Yasuyuki; Obara, Satoshi; Yamaguchi, Masae; Kawashima, Hajime; Kitamura, Hisashi; Kurano, Mieko; Uchihori, Yukio; Yasuda, Nakahiro; Koguchi, Yasuhiro; Nakajima, Masaru; Kitamura, Nozomi; Sato, Tomoharu
2015-04-01
We measured the recoil charged particles from secondary neutrons produced by the photonuclear reaction in a water phantom from a 10-MV photon beam from medical linacs. The absorbed dose and the dose equivalent were evaluated from the linear energy transfer (LET) spectrum of recoils using the CR-39 plastic nuclear track detector (PNTD) based on well-established methods in the field of space radiation dosimetry. The contributions and spatial distributions of these in the phantom on nominal photon exposures were verified as the secondary neutron dose and neutron dose equivalent. The neutron dose equivalent normalized to the photon-absorbed dose was 0.261 mSv/100 MU at source to chamber distance 90 cm. The dose equivalent at the surface gave the highest value, and was attenuated to less than 10% at 5 cm from the surface. The dose contribution of the high LET component of ⩾100 keV/μm increased with the depth in water, resulting in an increase of the quality factor. The CR-39 PNTD is a powerful tool that can be used to systematically measure secondary neutron dose distributions in a water phantom from an in-field to out-of-field high-intensity photon beam.
Pathway to Cryogen Free Production of Hyperpolarized Krypton-83 and Xenon-129
Six, Joseph S.; Hughes-Riley, Theodore; Stupic, Karl F.; Pavlovskaya, Galina E.; Meersmann, Thomas
2012-01-01
Hyperpolarized (hp) 129Xe and hp 83Kr for magnetic resonance imaging (MRI) are typically obtained through spin-exchange optical pumping (SEOP) in gas mixtures with dilute concentrations of the respective noble gas. The usage of dilute noble gases mixtures requires cryogenic gas separation after SEOP, a step that makes clinical and preclinical applications of hp 129Xe MRI cumbersome. For hp 83Kr MRI, cryogenic concentration is not practical due to depolarization that is caused by quadrupolar relaxation in the condensed phase. In this work, the concept of stopped flow SEOP with concentrated noble gas mixtures at low pressures was explored using a laser with 23.3 W of output power and 0.25 nm linewidth. For 129Xe SEOP without cryogenic separation, the highest obtained MR signal intensity from the hp xenon-nitrogen gas mixture was equivalent to that arising from 15.5±1.9% spin polarized 129Xe in pure xenon gas. The production rate of the hp gas mixture, measured at 298 K, was 1.8 cm3/min. For hp 83Kr, the equivalent of 4.4±0.5% spin polarization in pure krypton at a production rate of 2 cm3/min was produced. The general dependency of spin polarization upon gas pressure obtained in stopped flow SEOP is reported for various noble gas concentrations. Aspects of SEOP specific to the two noble gas isotopes are discussed and compared with current theoretical opinions. A non-linear pressure broadening of the Rb D1 transition was observed and taken into account for the qualitative description of the SEOP process. PMID:23209620
Bays, Harold E; Chen, Erluo; Tomassini, Joanne E; McPeters, Gail; Polis, Adam B; Triscari, Joseph
2015-04-01
Co-administration of ezetimibe with atorvastatin is a generally well-tolerated treatment option that reduces LDL-C levels and improves other lipids with greater efficacy than doubling the atorvastatin dose. The objective of the study was to demonstrate the equivalent lipid-modifying efficacy of fixed-dose combination (FDC) ezetimibe/atorvastatin compared with the component agents co-administered individually in support of regulatory filing. Two randomized, 6-week, double-blind cross-over trials compared the lipid-modifying efficacy of ezetimibe/atorvastatin 10/20 mg (n = 353) or 10/40 mg (n = 280) vs. separate co-administration of ezetimibe 10 mg plus atorvastatin 20 mg (n = 346) or 40 mg (n = 280), respectively, in hypercholesterolemic patients. Percent changes from baseline in LDL-C (primary endpoint) and other lipids (secondary endpoints) were assessed by analysis of covariance; triglycerides were evaluated by longitudinal-data analysis. Expected differences between FDC and the corresponding co-administered doses were predicted from a dose-response relationship model; sample size was estimated given the expected difference and equivalence margins (±4%). LDL-C-lowering equivalence was based on 97.5% expanded confidence intervals (CI) for the difference contained within the margins; equivalence margins for other lipids were not prespecified. Ezetimibe/atorvastatin FDC 10/20 mg was equivalent to co-administered ezetimibe+atorvastatin 20 mg in reducing LDL-C levels (54.0% vs. 53.8%) as was FDC 10/40 mg and ezetimibe+atorvastatin 40 mg (58.9% vs. 58.7%), as predicted by the model. Changes in other lipids were consistent with equivalence (97.5% expanded CIs <±3%, included 0); triglyceride changes varied more. All treatments were generally well tolerated. Hypercholesterolemic patients administered ezetimibe/atorvastatin 10/20 and 10/40 mg FDC had equivalent LDL-C lowering. This FDC formulation proved to be an efficacious and generally well-tolerated lipid-lowering therapy. © 2014 Société Française de Pharmacologie et de Thérapeutique.
Can we use the equivalent sphere model to approximate organ doses in space radiation environments?
NASA Astrophysics Data System (ADS)
Lin, Zi-Wei
For space radiation protection one often calculates the dose or dose equivalent in blood forming organs (BFO). It has been customary to use a 5cm equivalent sphere to approximate the BFO dose. However, previous studies have concluded that a 5cm sphere gives a very different dose from the exact BFO dose. One study concludes that a 9cm sphere is a reasonable approximation for the BFO dose in solar particle event (SPE) environments. In this study we investigate the reason behind these observations and extend earlier studies by studying whether BFO, eyes or the skin can be approximated by the equivalent sphere model in different space radiation environments such as solar particle events and galactic cosmic ray (GCR) environments. We take the thickness distribution functions of the organs from the CAM (Computerized Anatomical Man) model, then use a deterministic radiation transport to calculate organ doses in different space radiation environments. The organ doses have been evaluated with a water or aluminum shielding from 0 to 20 g/cm2. We then compare these exact doses with results from the equivalent sphere model and determine in which cases and at what radius parameters the equivalent sphere model is a reasonable approximation. Furthermore, we propose to use a modified equivalent sphere model with two radius parameters to represent the skin or eyes. For solar particle events, we find that the radius parameters for the organ dose equivalent increase significantly with the shielding thickness, and the model works marginally for BFO but is unacceptable for eyes or the skin. For galactic cosmic rays environments, the equivalent sphere model with one organ-specific radius parameter works well for the BFO dose equivalent, marginally well for the BFO dose and the dose equivalent of eyes or the skin, but is unacceptable for the dose of eyes or the skin. The BFO radius parameters are found to be significantly larger than 5 cm in all cases, consistent with the conclusion of an earlier study. The radius parameters for the dose equivalent in GCR environments are approximately between 10 and 11 cm for the BFO, 3.7 to 4.8 cm for eyes, and 3.5 to 5.6 cm for the skin; while the radius parameters are between 10 and 13 cm for the BFO dose. In the proposed modified equivalent sphere model, the range of each of the two radius parameters for the skin (or eyes) is much tighter than that in the equivalent sphere model with one radius parameter. Our results thus show that the equivalent sphere model works better in galactic cosmic rays environments than in solar particle events. The model works well or marginally well for BFO but usually does not work for eyes or the skin. A modified model with two radius parameters works much better in approximating the dose and dose equivalent in eyes or the skin.
Gokuladhas, Krishnan; Jayakumar, Subramaniyan; Rajan, Balan; Elamaran, Ramasamy; Pramila, Chengalvarayan Subramani; Gopikrishnan, Mani; Tamilarasi, Sasivarman; Devaki, Thiruvengadam
2016-04-01
Liver cancer is the fifth most common cancer and is still one of the leading causes of death world wide, due to food additives, alcohol, fungal toxins, air, toxic industrial chemicals, and water pollutants. Chemopreventive drugs play a potential role in liver cancer treatment. Obviously in the production of anticancer drugs, the factors like poor solubility, bioavailability, biocompatibility, limited chemical stability, large amount of dose etc., plays a major role. Against this backdrop, the idea of designing the chemopreventive nature of bio flavanoid hesperetin (HP) drug conjugated with pegylated gold nanoparticles to increasing the solubility, improve bioavailability and enhance the targeting capabilities of the drug during diethylnitrosamine (DEN) induced liver cancer in male wistar albino rats. The dose fixation studies and the toxicity of pure HP and HP conjugated gold nanoparticles (Au-mPEG(5000)-S-HP) were analysed. After concluded the dose fixation and toxicity studies the experimental design were segregated in six groups for the anticancer analysis of DEN induced HCC for 16 weeks. After the experimental period the body weight, relative liver weight, number of nodules and size of nodules, the levels of tumor markers like CEA, AFP and the level of lipid peroxidation, lipid hydroperoxides and the activities of antioxidant enzymes were assessed. The administration of DEN to rats resulted in increased relative liver weight and serum marker enzymes aspartate transaminase, alanine transaminase, alkaline phosphatase, lactate dehydrogenase, and gamma glutamyl transpeptidase. The levels of lipid peroxides elevated (in both serum and tissue) with subsequent decrease in the final body weight and tissue antioxidants like superoxide dismutase, catalase, reduced glutathione, glutathione peroxidise, and glutathione reductase. HP supplementation (20 mg/kg b.wt) significantly attenuated these alterations, thereby showing potent anticancer effect in liver cancer and the HP loaded gold nanoparticels (Au-mPEG(5000)-S-HP) treated animals shows the better treatment than the pure HP due to the solubility of drug, bioavailability and the target drug delivery of the biodegradable polymer. Histological observations were also carried out, which added supports to the chemopreventive action of the pure HP and HP loaded gold nanoparticles (Au-mPEG(5000)-S-HP) against DEN induction during liver cancer progression. These findings suggest that HP loaded gold nanoparticels (Au-mPEG(5000)-S-HP) shows better efficacy than the pure HP against lipid peroxidation, hepatic cell damage and protects the antioxidant system in DEN induced hepatocellular carcinogenesis.
Shepardson, D.; Marks, S. M.; Chesson, H.; Kerrigan, A.; Holland, D. P.; Scott, N.; Tian, X.; Borisov, A. S.; Shang, N.; Heilig, C. M.; Sterling, T. R.; Villarino, M. E.; Mac Kenzie, W. R.
2017-01-01
SUMMARY SETTING A large randomized controlled trial recently showed that for treating latent tuberculous infection (LTBI) in persons at high risk of progression to tuberculosis (TB) disease, a 12-dose regimen of weekly rifapentine plus isoniazid (3HP) administered as directly observed treatment (DOT) can be as effective as 9 months of daily self-administered isoniazid (9H). OBJECTIVES To assess the cost-effectiveness of 3HP compared to 9H. DESIGN A computational model was designed to simulate individuals with LTBI treated with 9H or 3HP. Costs and health outcomes were estimated to determine the incremental costs per active TB case prevented and per quality-adjusted life year (QALY) gained by 3HP compared to 9H. RESULTS Over a 20-year period, treatment of LTBI with 3HP rather than 9H resulted in 5.2 fewer cases of TB and 25 fewer lost QALYs per 1000 individuals treated. From the health system and societal perspectives, 3HP would cost respectively US$21 525 and $4294 more per TB case prevented, and respectively $4565 and $911 more per QALY gained. CONCLUSIONS 3HP may be a cost-effective alternative to 9H, particularly if the cost of rifapentine decreases, the effectiveness of 3HP can be maintained without DOT, and 3HP treatment is limited to those with a high risk of progression to TB disease. PMID:24200264
[STUDYING SOME PHARMACOLOGICAL EFFECTS OF NEW 3-HYDROXYPYRIDINE DERIVATIVE].
Yasnetsov, V V; Tsublova, E G; Yasnetsov, Vic V; Skachilova, S Ya; Karsanova, S K; Ivanov, Yu V
2016-01-01
It was established that a new 3-hydroxypyridine (3-HP) derivative, 2-ethyl-6-methyl-3-hydroxypyridine L-aspartate (3-HP), in small doses (1 and 5 mg/kg) increased physical performance in treadmill and swimming tests on rats. The new substance showed greater or equal effects compared to the reference actoprotector drugs metaprot and ladasten in much higher doses. The gluconeogenesis inhibitor tryptophan significantly (74 ± 5%, p < 0.01) prevented this stimulatory effect of 3-HPA in the treadmill test on rats. 3-HPA at a higher dose (30 mg/kg) had marked antiamnesic effect on various models of amnesia in mice. It was more effective than reference drugs mexidol (another 3-HP derivative) in a dose of 30 mg/kg and nootropic drug piracetam in a dose of 200 mg/kg, but had equal effect with these drugs in doses of 50 and 800 mg/kg, respectively. 3-HPA (30 mg/kg per day) had neuroprotective effect in rats with brain ischemia and decreased the neurologic deficiency more effectively than mexidol (50 mg/kg per day).
Code of Federal Regulations, 2013 CFR
2013-01-01
... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...
Code of Federal Regulations, 2012 CFR
2012-01-01
... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...
Code of Federal Regulations, 2014 CFR
2014-01-01
... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...
Code of Federal Regulations, 2011 CFR
2011-01-01
... of the deep dose equivalent and the committed dose equivalent to any individual organ or tissue (other than the lens of the eye) of 0.5 Sv (50 rem). The lens dose equivalent may not exceed 0.15 Sv (15... TEDE (hereafter referred to as “dose”) to any real member of the public located beyond the boundary of...
Pluronic based β-cyclodextrin polyrotaxanes for treatment of Niemann-Pick Type C disease
NASA Astrophysics Data System (ADS)
Collins, Christopher J.; Loren, Bradley P.; Alam, Md Suhail; Mondjinou, Yawo; Skulsky, Joseph L.; Chaplain, Cheyenne R.; Haldar, Kasturi; Thompson, David H.
2017-04-01
Niemann-Pick Type C disease (NPC) is a rare metabolic disorder characterized by disruption of normal cholesterol trafficking within the cells of the body. There are no FDA approved treatments available for NPC patients. Recently, the cycloheptaglucoside 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) has shown efficacy as a potential NPC therapeutic by extending lifetime in NPC mice, delaying neurodegeneration, and decreasing visceral and neurological cholesterol burden. Although promising, systemic HP-β-CD treatment is limited by a pharmacokinetic profile characterized by rapid loss through renal filtration. To address these shortcomings, we sought to design a family of HP-β-CD pro-drug delivery vehicles, known as polyrotaxanes (PR), capable of increasing the efficacy of a given injected dose by improving both pharmacokinetic profile and bioavailability of the HP-β-CD agent. PR can effectively diminish the cholesterol pool within the liver, spleen, and kidney at molar concentrations 10-to-100-fold lower than monomeric HP-β-CD. In addition to this proof-of-concept, use of PR scaffolds with differing physiochemical properties reveal structure-activity relationships in which PR characteristics, including hydrophobicity, threading efficiency and surface charge, were found to both decisively and subtly effect therapeutic efficacy. PR scaffolds exhibit absorption, pharmacokinetics, and biodistribution patterns that are significantly altered from monomeric HP-β-CD. In all, PR scaffolds hold great promise as potential treatments for visceral disease in NPC patients.
Pluronic based β-cyclodextrin polyrotaxanes for treatment of Niemann-Pick Type C disease.
Collins, Christopher J; Loren, Bradley P; Alam, Md Suhail; Mondjinou, Yawo; Skulsky, Joseph L; Chaplain, Cheyenne R; Haldar, Kasturi; Thompson, David H
2017-04-28
Niemann-Pick Type C disease (NPC) is a rare metabolic disorder characterized by disruption of normal cholesterol trafficking within the cells of the body. There are no FDA approved treatments available for NPC patients. Recently, the cycloheptaglucoside 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) has shown efficacy as a potential NPC therapeutic by extending lifetime in NPC mice, delaying neurodegeneration, and decreasing visceral and neurological cholesterol burden. Although promising, systemic HP-β-CD treatment is limited by a pharmacokinetic profile characterized by rapid loss through renal filtration. To address these shortcomings, we sought to design a family of HP-β-CD pro-drug delivery vehicles, known as polyrotaxanes (PR), capable of increasing the efficacy of a given injected dose by improving both pharmacokinetic profile and bioavailability of the HP-β-CD agent. PR can effectively diminish the cholesterol pool within the liver, spleen, and kidney at molar concentrations 10-to-100-fold lower than monomeric HP-β-CD. In addition to this proof-of-concept, use of PR scaffolds with differing physiochemical properties reveal structure-activity relationships in which PR characteristics, including hydrophobicity, threading efficiency and surface charge, were found to both decisively and subtly effect therapeutic efficacy. PR scaffolds exhibit absorption, pharmacokinetics, and biodistribution patterns that are significantly altered from monomeric HP-β-CD. In all, PR scaffolds hold great promise as potential treatments for visceral disease in NPC patients.
10 CFR 835.203 - Combining internal and external equivalent doses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and... the radiation and tissue weighting factor values provided in § 835.2. [72 FR 31926, June 8, 2007] ...
10 CFR 835.203 - Combining internal and external equivalent doses.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and... the radiation and tissue weighting factor values provided in § 835.2. [72 FR 31926, June 8, 2007] ...
10 CFR 835.203 - Combining internal and external equivalent doses.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and... the radiation and tissue weighting factor values provided in § 835.2. [72 FR 31926, June 8, 2007] ...
10 CFR 835.203 - Combining internal and external equivalent doses.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and... the radiation and tissue weighting factor values provided in § 835.2. [72 FR 31926, June 8, 2007] ...
Radiation exposure from consumer products and miscellaneous sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1977-01-01
This review of the literature indicates that there is a variety of consumer products and miscellaneous sources of radiation that result in exposure to the U.S. population. A summary of the number of people exposed to each such source, an estimate of the resulting dose equivalents to the exposed population, and an estimate of the average annual population dose equivalent are tabulated. A review of the data in this table shows that the total average annual contribution to the whole-body dose equivalent of the U.S. population from consumer products is less than 5 mrem; about 70 percent of this arisesmore » from the presence of naturally-occurring radionuclides in building materials. Some of the consumer product sources contribute exposure mainly to localized tissues or organs. Such localized estimates include: 0.5 to 1 mrem to the average annual population lung dose equivalent (generalized); 2 rem to the average annual population bronchial epithelial dose equivalent (localized); and 10 to 15 rem to the average annual population basal mucosal dose equivalent (basal mucosa of the gum). Based on these estimates, these sources may be grouped or classified as those that involve many people and the dose equivalent is relative large or those that involve many people but the dose equivalent is relatively small, or the dose equivalent is relatively large but the number of people involved is small.« less
Antioxidant and cytotoxic properties of lyophilized beer extracts on HL-60 cell line.
Tedesco, Idolo; Nappo, Annunziata; Petitto, Fabio; Iacomino, Giuseppe; Nazzaro, Filomena; Palumbo, Rosanna; Russo, Gian Luigi
2005-01-01
An impressive number of studies have suggested that red wine can be considered the protective beverage of choice against chronic and degenerative pathologies. Only few and controversial data are available on a potential, similar role for beer, which represents a more cost-effective, safe, and widely available beverage. Starting from the evidence that many antioxidant compounds present in red wine are also present at similar or even higher concentrations in beers, we first screened 48 commercially available beers and selected one (Mrt-HP) with very high polyphenol concentration and antioxidant activity estimated by ferric reducing antioxidant power. We demonstrated that a lyophilized preparation of Mrt-HP beer was cytotoxic with respect to a beer with low polyphenolic content (Trt-LP) when assayed on HL-60 human leukemia cell line. We measured a 60% decrease in cell viability at a polyphenol concentration of 250 microM quercetin equivalents. We also demonstrated that Mrt-HP cytotoxicity was not an artifact due to cell growth conditions because addition of Mrt-HP extracts to cell medium generated peroxide levels indistinguishable from controls. By means of cytofluorimetric analysis of pre-G1 population and caspase 3 activation, we demonstrated that Mrt-HP extracts activated apoptosis in HL-60 cell line. Finally, we found that the concentration of quercetin, resveratrol, and gallic acid in Mrt-HP was 10, 4.6, and 4.6-fold higher, respectively, than in Trt-LP, suggesting that the presence of these molecules might be responsible for the observed cytotoxicity. These data, together with the low in vivo beer toxicity reported in the literature, suggest a possible chemopreventive role for this beverage that requires further studies in animal models.
Sayer, R. D.; Speaker, K. J.; Pan, Z.; Peters, J. C.; Wyatt, H. R.
2017-01-01
Summary Objective The objective of this randomized equivalence trial was to determine the impact of consuming lean beef as part of a high protein (HP) weight‐reducing diet on changes in body weight, body composition and cardiometabolic health. Methods A total of 120 adults (99 female) with overweight or obesity (BMI: 35.7 ± 7.0 kg m−2) were randomly assigned to consume either a HP diet with ≥4 weekly servings of lean beef (B; n = 60) or a HP diet restricted in all red meats (NB; n = 60) during a 16‐week weight loss intervention. Results Body weight was reduced by 7.8 ± 5.9% in B and 7.7 ± 5.5% in NB (p < 0.01 for both). Changes in percent body weight were equivalent between B and NB (mean difference: 0.06%, 90% confidence interval: (−1.7, 1.8)). Fat mass was reduced in both groups (p < 0.01; B: 8.0 ± 0.6 kg, NB: 8.6 ± 0.6 kg), while lean mass was not reduced in either group. Improvements in markers of cardiometabolic health (total cholesterol, low‐density lipoprotein cholesterol, triglycerides and blood pressure) were not different between B and NB. Conclusion Results of this study demonstrate that HP diets – either rich or restricted in red meat intakes – are effective for decreasing body weight and improving body composition and cardiometabolic health. PMID:29071106
Sayer, R D; Speaker, K J; Pan, Z; Peters, J C; Wyatt, H R; Hill, J O
2017-09-01
The objective of this randomized equivalence trial was to determine the impact of consuming lean beef as part of a high protein (HP) weight-reducing diet on changes in body weight, body composition and cardiometabolic health. A total of 120 adults (99 female) with overweight or obesity (BMI: 35.7 ± 7.0 kg m -2 ) were randomly assigned to consume either a HP diet with ≥4 weekly servings of lean beef (B; n = 60) or a HP diet restricted in all red meats (NB; n = 60) during a 16-week weight loss intervention. Body weight was reduced by 7.8 ± 5.9% in B and 7.7 ± 5.5% in NB ( p < 0.01 for both). Changes in percent body weight were equivalent between B and NB (mean difference: 0.06%, 90% confidence interval: (-1.7, 1.8)). Fat mass was reduced in both groups ( p < 0.01; B: 8.0 ± 0.6 kg, NB: 8.6 ± 0.6 kg), while lean mass was not reduced in either group. Improvements in markers of cardiometabolic health (total cholesterol, low-density lipoprotein cholesterol, triglycerides and blood pressure) were not different between B and NB. Results of this study demonstrate that HP diets - either rich or restricted in red meat intakes - are effective for decreasing body weight and improving body composition and cardiometabolic health.
In vitro studies of chlorin e6-assisted photodynamic inactivation of Helicobacter pylori
NASA Astrophysics Data System (ADS)
Simon, C.; Mohrbacher, C.; Hüttenberger, D.; Bauer-Marschall, Ina; Krickhahn, C.; Stachon, A.; Foth, H.-J.
2014-03-01
Helicobacter pylori (HP), a gram-negative microaerophilic bacterium located in gastric mucosa, plays an im- portant role in gastro carcinogenesis. Due to the increasing emergence of antibiotic resistance, photodynamic inactivation of bacteria presents a new approach to treat bacterial infections, like HP. In vitro experiments were performed to determine the irradiation conditions for a complete inactivation of HP with the photosensitizer Chlorin e6 (Ce6). The HP strain CCUG 38770 (Culture Collection, University of Gothenburg, Sweden) was routinely cultured under microaerophilic conditions, suspended in sodium chloride, incubated with Ce6 and irradiated briefly with red light of the appropriate wavelength of λ = 660 nm. Series of measurements of different Ce6-concentrations (0.1 μM - 100 μM) were carried out, whereby the incubation time was kept constant at 1 min. The absorbed energy dose has been selected in varying the irradiation time (1 s - 300 s) and the power density (4.5 mW/cm2 - 31 mW/cm2 ). Quantification of inactivation was performed by enumeration of the grown colonies. In addition, the accumulation of Ce6 in HP cells was studied more precisely by uorescence spectroscopy. With a Ce6 concentration of 100 μM and a power density of 9 mW cm2 , a 6-log10 reduction in the survival rate of HP was achieved within 30 seconds of irradiation. In conclusion the most relevant factor for the inactivation of HP is the exposure time of irradiation, followed by the concentration of Ce6 and the light intensity. Further studies with HP strains obtained from patient specimens are under current investigation.
Heavy ion contributions to organ dose equivalent for the 1977 galactic cosmic ray spectrum
NASA Astrophysics Data System (ADS)
Walker, Steven A.; Townsend, Lawrence W.; Norbury, John W.
2013-05-01
Estimates of organ dose equivalents for the skin, eye lens, blood forming organs, central nervous system, and heart of female astronauts from exposures to the 1977 solar minimum galactic cosmic radiation spectrum for various shielding geometries involving simple spheres and locations within the Space Transportation System (space shuttle) and the International Space Station (ISS) are made using the HZETRN 2010 space radiation transport code. The dose equivalent contributions are broken down by charge groups in order to better understand the sources of the exposures to these organs. For thin shields, contributions from ions heavier than alpha particles comprise at least half of the organ dose equivalent. For thick shields, such as the ISS locations, heavy ions contribute less than 30% and in some cases less than 10% of the organ dose equivalent. Secondary neutron production contributions in thick shields also tend to be as large, or larger, than the heavy ion contributions to the organ dose equivalents.
SU-G-IeP3-13: Real-Time Patient and Staff Dose Monitoring in Fluoroscopy Guided Interventions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vergoossen, L; Sailer, A; Paulis, L
Purpose: Interventional radiology procedures involve the use of X-rays, which can pose a large radiation burden on both patients and staff. Although some reports on radiation dose are available, most studies focus on limited types of procedures and only report patient dose. In our cathlabs a dedicated real-time patient and staff monitoring system was installed in November 2015. The aim of this study was to investigate the patient and staff dose exposure for different types of interventions. Methods: Radiologists involved in fluoroscopy guided interventional radiology procedures wore personal dose meters (PDM, DoseAware, Philips) on their lead-apron that measured the personalmore » dose equivalent Hp(10), a measure for the effective dose (E). Furthermore, reference PDMs were installed in the C-arms of the fluoroscopy system (Allura XPer, Philips). Patient dose-area-product (DAP) and PDM doses were retrieved from the monitoring system (DoseWise, Philips) for each procedure. A total of 399 procedures performed between November 2015 and February 2016 were analyzed with respect to the type of intervention. Interventions were grouped by anatomy and radiologist position. Results: The mean DAP for the different types of interventions ranged from 2.86±2.96 Gycm{sup 2} (percutaneous gastrostomy) to 147±178 Gycm{sup 2} (aortic repair procedures). The radiologist dose (E) ranged from 5.39±7.38 µSv (cerebral interventions) to 84.7±106 µSv (abdominal interventions) and strongly correlated with DAP (R{sup 2}=0.83). The E normalized to DAP showed that the relative radiologist dose was higher for interventions in larger body parts (e.g. abdomen) compared to smaller body parts (e.g. head). Conclusion: Using a real-time dose monitoring system we were able to assess the staff and patient dose revealing that the relative staff dose strongly depended on the type of procedure and patient anatomy. This could be explained by the position of the radiologist with respect to the patient and X-ray tube. To facilitate this study L Vergoossen received a scholarship from Philips Medical Systems.« less
Evaluation of porphyrin C analogues for photodynamic therapy of cerebral glioma.
Karagianis, G; Hill, J S; Stylli, S S; Kaye, A H; Varadaxis, N J; Reiss, J A; Phillips, D R
1996-02-01
A series of monomeric porphyrins (2-8) based on porphyrin C (1) have been tested as sensitisers for photodynamic therapy (PDT) of cerebral glioma using the in vitro/in vivo C6 intracerebral animal tumour model. The in vivo screening, consisting of cytotoxicity, phototoxicity (red light) and subcellular localisation studies, revealed two sensitisers (porphyrin 7, molecular weight 863 Da and porphyrin 8, molecular weight 889 Da), which had greater photoactivity than porphyrin C and similar photoactivity to haematoporphyrin derivative (HpD) although at a 5-fold higher dose than HpD. Both sensitisers showed intracellular localisation to discrete organelle sites and exhibited considerably less 'dark' cytotoxicity than HpD. The kinetics of uptake of porphyrins 7 and 8 was studied in the mouse C6 glioma model as well as in biopsy samples from normal brain, liver, spleen and blood. Maximal drug uptake levels in tumour occurred 9 and 6 h after intraperitoneal injection for 7 and 8 respectively, at which time the tumour to normal brain ratios were 15:1 and 13:1 respectively. The effect of PDT using porphyrin 7 activated by the gold metal vapour laser tuned to 627.8 nm was studied in Wistar rats bearing intracerebral C6 glioma. At a drug dose of 10 mg porphyrin 7 kg-1 body weight and laser doses of up to 400 J cm-2 light, selective tumour kill with sparing of normal brain was achieved, with a maximal depth of tumour kill of 1.77+/-0.40. mm. Irradiation following a higher drug dose of 75 mg porphyrin 7 kg-1 body weight resulted in a greater depth of tumour kill, but also significantly increased the likelihood and extent of necrosis in normal brain.
Neutron scattered dose equivalent to a fetus from proton radiotherapy of the mother.
Mesoloras, Geraldine; Sandison, George A; Stewart, Robert D; Farr, Jonathan B; Hsi, Wen C
2006-07-01
Scattered neutron dose equivalent to a representative point for a fetus is evaluated in an anthropomorphic phantom of the mother undergoing proton radiotherapy. The effect on scattered neutron dose equivalent to the fetus of changing the incident proton beam energy, aperture size, beam location, and air gap between the beam delivery snout and skin was studied for both a small field snout and a large field snout. Measurements of the fetus scattered neutron dose equivalent were made by placing a neutron bubble detector 10 cm below the umbilicus of an anthropomorphic Rando phantom enhanced by a wax bolus to simulate a second trimester pregnancy. The neutron dose equivalent in milliSieverts (mSv) per proton treatment Gray increased with incident proton energy and decreased with aperture size, distance of the fetus representative point from the field edge, and increasing air gap. Neutron dose equivalent to the fetus varied from 0.025 to 0.450 mSv per proton Gray for the small field snout and from 0.097 to 0.871 mSv per proton Gray for the large field snout. There is likely to be no excess risk to the fetus of severe mental retardation for a typical proton treatment of 80 Gray to the mother since the scattered neutron dose to the fetus of 69.7 mSv is well below the lower confidence limit for the threshold of 300 mGy observed for the occurrence of severe mental retardation in prenatally exposed Japanese atomic bomb survivors. However, based on the linear no threshold hypothesis, and this same typical treatment for the mother, the excess risk to the fetus of radiation induced cancer death in the first 10 years of life is 17.4 per 10,000 children.
Assessment of radiation doses from residential smoke detectors that contain americium-241
NASA Astrophysics Data System (ADS)
Odonnell, F. R.; Etnier, E. L.; Holton, G. A.; Travis, C. C.
1981-10-01
External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv to 20 nSv for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 micro-Sv (0.0006 to 8 mrem) to total body and from 0.06 to 800 micro-Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft squared.
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2013 CFR
2013-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2010 CFR
2010-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2014 CFR
2014-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2011 CFR
2011-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
14 CFR Appendix A to Part 121 - First Aid Kits and Emergency Medical Kits
Code of Federal Regulations, 2012 CFR
2012-01-01
..., 50cc 1 Epinephrine 1:1000, single dose ampule or equivalent) 2 Diphenhydramine HC1 injection, single dose ampule or equivalent 2 Nitroglycerin tablets 10 Basic instructions for use of the drugs in the kit 1 protective nonpermeable gloves or equivalent 1 pair 2. As of April 12, 2004, at least one approved...
Early Stage Blood Purification for Paraquat Poisoning: A Multicenter Retrospective Study.
Li, An; Li, Wenxiong; Hao, Fengtong; Wang, Haishi
2016-01-01
To evaluate the efficacy of conservative treatment vs. hemoperfusion (HP) vs. HP + continuous veno-venous hemofiltration (CVVH) for acute Paraquat (PQ) poisoning. This was a multicenter retrospective study of patients with PQ poisoning between January 2013 and June 2014. Clinical data and PQ serum levels were collected at baseline and after 24, 48, and 72 h of treatment. Seventy-five, 65, and 43 underwent conservative treatment only (conservative treatment group), conservative treatment + HP (HP group), and conservative treatment + HP + CVVH (HP + CVVH group), respectively. PQ serum levels decreased in all groups after 72 h of treatment (p < 0.001); meanwhile, these values decreased faster in the HP and HP + CVVH groups compared with the conservative treatment group. More importantly, PQ blood levels were significantly lower in the HP + CVVH group compared with the HP group at 24 h (p < 0.05). Sequential organ failure assessment (ΔSOFA) values in the HP and HP + CVVH groups were significantly lower compared with that obtained for the conservative treatment group (p < 0.05). The 60-day survival rates were 21.3, 43.1 and 46.5%, respectively. Multivariate analysis indicated that age, PQ dose, admission PQ levels, and admission SOFA score were independently associated with mortality. HP and HP + CVVH were protective factors. Early HP or HP + CVVH after PQ poisoning could decrease PQ blood levels, alleviate organ damage, and increase survival. © 2016 S. Karger AG, Basel.
Esteves, Sandro C; Schertz, Joan C; Verza, Sidney; Schneider, Danielle T; Zabaglia, Silval FC
2009-01-01
Background Over the last several decades, as a result of an evolution in manufacturing processes, a marked development has been made in the field of gonadotropins for ovarian stimulation. Initially, therapeutic gonadotropins were produced from a simple process of urine extraction and purification; now they are produced via a complex system involving recombinant technology, which yields gonadotropins with high levels of purity, quality, and consistency. Methods A retrospective analysis of 865 consecutive intracytoplasmic sperm injection (ICSI) cycles of controlled ovarian hyperstimulation (COH) compared the clinical efficacy of three gonadotropins (menotropin [hMG; n = 299], highly-purified hMG [HP-hMG; n = 330] and follitropin alfa [r-hFSH; n = 236]) for ovarian stimulation after pituitary down-regulation. The endpoints were live birth rates and total doses of gonadotropin per cycle and per pregnancy. Results Laboratory and clinical protocols remained unchanged over time, except for the type of gonadotropin used, which was introduced sequentially (hMG, then HP-hMG, and finally r-hFSH). Live birth rates were not significantly different for hMG (24.4%), HP-hMG (32.4%) and r-hFSH (30.1%; p = 0.09) groups. Total dose of gonadotropin per cycle was significantly higher in the hMG (2685 +/- 720 IU) and HP-hMG (2903 +/- 867 IU) groups compared with the r-hFSH-group (2268 +/- 747 IU; p < 0.001). Total dose of gonadotropin required to achieve clinical pregnancy was 15.7% and 11.0% higher for the hMG and HP-hMG groups, respectively, compared with the r-hFSH group, and for live births, the differences observed were 45.3% and 19.8%, respectively. Conclusion Although similar live birth rates were achieved, markedly lower doses of r-hFSH were required compared with hMG or HP-hMG. PMID:19828024
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
10 CFR 835.206 - Limits for the embryo/fetus.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Limits for the embryo/fetus. 835.206 Section 835.206... Exposure § 835.206 Limits for the embryo/fetus. (a) The equivalent dose limit for the embryo/fetus from the... provided in § 835.206(a) shall be avoided. (c) If the equivalent dose to the embryo/fetus is determined to...
Parkhouse, R Michael E; Carpio, Arturo; Campoverde, Alfredo; Sastre, Patricia; Rojas, Glenda; Cortez, María Milagros
2018-02-01
To evaluate diagnosis of active neurocysticercosis, paired cerebral spinal fluid (CSF) and serum samples from 24 neurocysticercosis (NCC) patients and 17 control neurological patients were assayed in the HP10 Taenia antigen (Ag) ELISA. The CSF samples were also tested with an HP10 Lateral Flow Assay (LFA). The HP10 Ag was detected by ELISA in the CSF of 5/5 patients with Definitive extraparenchymal NCC, and in 4/5 of the corresponding sera. In the Definitive parenchymal group, on the other hand, the HP10 Ag was absent in 2/3 CSF (with a very low value in the one positive sample) and all the corresponding serum samples. Samples of CSF from 4/7 patients in the Probable parenchymal group, were also significantly HP10 Ag positive, suggesting the presence of extraparenchymal cysts not identified by the imaging studies. With the possible exception of one patient, the corresponding serum samples of the Probable parenchymal NCC group, were all HP10 Ag negative. Samples of CSF from 9 NCC patients diagnosed with Mixed parenchymal and extraparenchymal NCC were all significantly HP10 Ag positive, confirming the presence of extraparenchymal cysts, with only 7/9 of the corresponding serum samples being HP10 positive. Thus detection of the HP10 Ag indicates extraparenchymal and not parenchymal cyst localization and is more sensitive with CSF than serum. Three neurological patients clinically diagnosed as subarachnoid cyst, hydrocephalus and tuberculoma, respectively, were clearly positive for HP10 Ag. Of these, two were confirmed as NCC by subsequent imaging; the third died prior to further examination. Thus, a total of 8 patients had their clinical diagnosis questioned. Finally, there was good agreement between the HP10 Ag ELISA and LFA with CSF samples giving an optical density ≥0.4 in the ELISA assay. In conclusion, the HP10 Ag assay should provide a valuable and reciprocal tool in the clinical diagnosis and follow up of extraparenchymal NCC. Copyright © 2017 Elsevier B.V. All rights reserved.
Quality factor and dose equivalent investigations aboard the Soviet Space Station Mir
NASA Astrophysics Data System (ADS)
Bouisset, P.; Nguyen, V. D.; Parmentier, N.; Akatov, Ia. A.; Arkhangel'Skii, V. V.; Vorozhtsov, A. S.; Petrov, V. M.; Kovalev, E. E.; Siegrist, M.
1992-07-01
Since Dec 1988, date of the French-Soviet joint space mission 'ARAGATZ', the CIRCE device, had recorded dose equivalent and quality factor values inside the Mir station (380-410 km, 51.5 deg). After the initial gas filling two years ago, the low pressure tissue equivalent proportional counter is still in good working conditions. Some results of three periods are presented. The average dose equivalent rates measured are respectively 0.6, 0.8 and 0.6 mSv/day with a quality factor equal to 1.9. Some detailed measurements show the increasing of the dose equivalent rates through the SAA and near polar horns. The real time determination of the quality factors allows to point out high linear energy transfer events with quality factors in the range 10-20.
The Evaluation of the 0.07 and 3 mm Dose Equivalent with a Portable Beta Spectrometer
NASA Astrophysics Data System (ADS)
Hoshi, Katsuya; Yoshida, Tadayoshi; Tsujimura, Norio; Okada, Kazuhiko
Beta spectra of various nuclide species were measured using a commercially available compact spectrometer. The shape of the spectra obtained via the spectrometer was almost similar to that of the theoretical spectra. The beta dose equivalent at any depth was obtained as a product of the measured pulse height spectra and the appropriate conversion coefficients of ICRP Publication 74. The dose rates evaluated from the spectra were comparable with the reference dose rates of standard beta calibration sources. In addition, we were able to determine the dose equivalents with a relative error of indication of 10% without the need for complicated correction.
Stabilization of source-separated human urine by chemical oxidation.
Zhang, Yang; Li, Zifu; Zhao, Yuan; Chen, Shuangling; Mahmood, Ibrahim Babatunde
2013-01-01
The inhibitory effect of ozone and hydrogen peroxide (HP) on urea hydrolysis in stored urine was investigated and compared. Ozone showed less effect on urea hydrolysis due to the complicated composition of urine (including a large amount of urease-producing bacteria) and bacteria regeneration. Ozone concentration and total heterotrophic bacteria analysis demonstrated that residual ozone concentration decreased by 43% within 15 hr from 13.50 to 7.72 mg/L in the one-time ozonation urine test, and finally completely decomposed within 4 days. In addition, bacteria regenerated quickly after ozone completely decomposed. However, HP showed a significant effect on inhibiting urea hydrolysis not only in stored urine but also in fecal-contaminated urine. The suitable doses of applied HP to inhibit urea hydrolysis in stored urine, concentrations of 0.5 and 1.0 g feces per liter of fecal-contaminated urine, were 0.03, 0.16 and 0.23 mol/L, respectively. The urea concentrations after 2 months stored were 7,145, 7,109 and 7,234 mg/L, respectively.
Rizk, C; Vanhavere, F
2016-09-01
The personal dosimetry service at the Lebanese Atomic Energy Commission uses Harshaw 8814 cards with LiF:Mg,Ti detectors. The dosemeters are read in a Harshaw 6600 TLD reader. In the process of accreditation for the ISO 17025 standard((1)), different influence factors are investigated and the uncertainty has been determined. The Individual Monitoring Service Laboratory-LAEC reads the dosemeters once it receives them from the customer, and new cards are immediately given for the next wearing period. The wearing period is 2 months. The dosemeter results are reported to the customers without background subtraction. Both Hp(10) and Hp(0.07) are reported. For this paper, only the uncertainty on Hp(10) will be focussed. The following factors are taken into account for the uncertainty: calibration factor, dosemeter homogeneity and repeatability, energy and angular dependence, non-linearity, temperature dependence, etc. Also the detection limit was determined. One of the important factors is the correction for fading. This fading correction depends on the procedure used such as storage temperatures, the time-temperature profile of the read-out, pre-heat and annealing conditions. Pre- and post-irradiation fading curves were measured for a storage period up to 182 d at room temperature (15-25°C). The resulting final combined standard uncertainty on the reported doses is of the order of 24 % for doses of ∼1 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Biji, C P; Sudheendrakumar, V V; Sajeev, T V
2006-09-01
Hyblaea puera nucleoployhedrovirus (HpNPV) is a potential biocontrol agent of the teak defoliator, Hyblaea puera (Cramer) (Lepidoptera: Hyblaeidae). To quantify the growth of the virus in the host larvae, three larval stages of the teak defoliator were subjected to quantitative bioassays using specified dilutions of HpNPV. The HpNPV production was found to be dependent on the dose, incubation period as well as stage specific responses of the host insect used. As larvae matured, production of the virus per mg body weight was not found to be in a constant proportion to the increase in the body weight. The combination which yielded the greatest virus production of 3.55 x 10(9) polyhedral occlusion bodies (POBs) was that in which larva weighing 26-37 mg was fed with 1 x 10(6) POBs, incubated for 6 h and harvested at 72 h post infection (h p.i.). The response of the fourth instar larvae was found to be more productive than the third and fifth instar larvae, which makes it an ideal candidate for mass production of the virus in vivo.
Souza, Priscila Morais Galvão; Carvalho, Bruno Ramalho de; Nakagawa, Hitomi Miura; Rassi, Thalita Reis Esselin; Barbosa, Antônio César Paes; Silva, Adelino Amaral
2017-06-01
This study aimed to compare the outcomes of controlled ovarian stimulation (COS) with corifollitropin alfa versus daily recombinant follicle-stimulating hormone (rRFSH) or highly purified human menopausal gonadotropin (HP-HMG) in patients undergoing in vitro fertilization (IVF) cycles based on gonadotropin-releasing hormone (GnRH) antagonist protocols. The primary endpoints were total number of oocytes and mature oocytes. This retrospective study looked into 132 controlled ovarian stimulation cycles from IVF or oocyte cryopreservation performed in a private human reproduction center between January 1 and December 31, 2014. Enrollment criteria: women aged < 40 years submitted to COS with corifollitropin alfa 100µg or 150µg (n = 26) and rFSH or HP-HMG in the first seven days of treatment with daily doses of 150-225 IU (n = 106); all subjects were on GnRH antagonist protocols. The groups had similar mean ages and duration of stimulation. The mean number ± standard deviation of total aspirated oocytes and MII oocytes was 11.9±10 and 10.3±7.9 in the corifollitropin alfa group, and 10.9±7.2 and 8.6±5.7 in the group on rFSH or HMG (p>0.05). There were no significant differences in fertilization (76.9% vs. 76.8%, p=1.0), biochemical pregnancy (66.7% vs. 47.2%, p=0.1561) or embryo implantation rates (68.7% vs. 50%, p=0.2588) between the groups using corifollitropin alfa and rFSH or HMG, respectively. Corifollitropin alfa seems to be as effective as rFSH or HP-HMG when used in the first seven days of ovulation induction for patients undergoing assisted reproduction in GnRH antagonist protocols.
Shielding implications for secondary neutrons and photons produced within the patient during IMPT.
DeMarco, J; Kupelian, P; Santhanam, A; Low, D
2013-07-01
Intensity modulated proton therapy (IMPT) uses a combination of computer controlled spot scanning and spot-weight optimized planning to irradiate the tumor volume uniformly. In contrast to passive scattering systems, secondary neutrons and photons produced from inelastic proton interactions within the patient represent the major source of emitted radiation during IMPT delivery. Various published studies evaluated the shielding considerations for passive scattering systems but did not directly address secondary neutron production from IMPT and the ambient dose equivalent on surrounding occupational and nonoccupational work areas. Thus, the purpose of this study was to utilize Monte Carlo simulations to evaluate the energy and angular distributions of secondary neutrons and photons following inelastic proton interactions within a tissue-equivalent phantom for incident proton spot energies between 70 and 250 MeV. Monte Carlo simulation methods were used to calculate the ambient dose equivalent of secondary neutrons and photons produced from inelastic proton interactions in a tissue-equivalent phantom. The angular distribution of emitted neutrons and photons were scored as a function of incident proton energy throughout a spherical annulus at 1, 2, 3, 4, and 5 m from the phantom center. Appropriate dose equivalent conversion factors were applied to estimate the total ambient dose equivalent from secondary neutrons and photons. A reference distance of 1 m from the center of the patient was used to evaluate the mean energy distribution of secondary neutrons and photons and the resulting ambient dose equivalent. For an incident proton spot energy of 250 MeV, the total ambient dose equivalent (3.6 × 10(-3) mSv per proton Gy) was greatest along the direction of the incident proton spot (0°-10°) with a mean secondary neutron energy of 71.3 MeV. The dose equivalent decreased by a factor of 5 in the backward direction (170°-180°) with a mean energy of 4.4 MeV. An 8 × 8 × 8 cm(3) volumetric spot distribution (5 mm FWHM spot size, 4 mm spot spacing) optimized to produce a uniform dose distribution results in an ambient dose equivalent of 4.5 × 10(-2) mSv per proton Gy in the forward direction. This work evaluated the secondary neutron and photon emission due to monoenergetic proton spots between 70 and 250 MeV, incident on a tissue equivalent phantom. Example calculations were performed to estimate concrete shield thickness based upon appropriate workload and shielding design assumptions. Although lower than traditional passive scattered proton therapy systems, the ambient dose equivalent from secondary neutrons produced by the patient during IMPT can be significant relative to occupational and nonoccupational workers in the vicinity of the treatment vault. This work demonstrates that Monte Carlo simulations are useful as an initial planning tool for studying the impact of the treatment room and maze design on surrounding occupational and nonoccupational work areas.
Buddle, Bryce M; Hewinson, R Glyn; Vordermeier, H Martin; Wedlock, D Neil
2013-10-01
Vaccination of cattle with a commercial human tuberculosis (TB) vaccine, Mycobacterium bovis bacillus Calmette-Guérin (BCG) Danish, at a dose equivalent to 5 human doses of BCG has protected these animals against TB in field and experimental trials. There is interest in determining whether a 10-fold-lower dose could still protect cattle but not induce a tuberculin intradermal test response. Two groups of calves (n = 9/group) were vaccinated subcutaneously with a lyophilized BCG Danish vaccine containing either 0.5 (1 × 10(5) to 4 × 10(5) CFU) or 5 (1 × 10(6) to 4 × 10(6) CFU) human doses of BCG Danish, with an additional group of 10 calves serving as nonvaccinated controls. Fifteen weeks after vaccination, these animals were challenged intratracheally with 5 × 10(3) CFU of virulent M. bovis and another 15 weeks later were slaughtered and examined for the presence of tuberculous lesions. Vaccination of the calves with either 0.5 or 5 equivalent human doses of BCG Danish induced similar levels of protection against challenge with M. bovis, with both groups showing significant reductions in the pathological and microbiological parameters compared to those for the the control group (P < 0.05). Vaccination with either of the two BCG doses induced similar numbers of animals responding to the tuberculin intradermal test at 11 weeks postvaccination. Vaccination with a 0.5 equivalent human dose of a commercial lyophilized BCG vaccine can protect cattle against challenge with M. bovis.
Assessment of radiation doses from residential smoke detectors that contain americium-241
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Donnell, F.R.; Etnier, E.L.; Holton, G.A.
1981-10-01
External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq (3 ..mu..Ci) americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv (0.4 prem) to 20 nSv (2 ..mu..rem) for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 ..mu..Svmore » (0.0006 to 8 mrem) to total body and from 0.06 to 800 ..mu..Sv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated to be about 0.38 person-Sv (38 person-rem) to total body and 00 ft/sup 2/).« less
U.S.-China Strategic Dialogue, Phase IX Report
2018-03-01
electron volt (eV) 1.602 177 × 10 –19 joule (J) erg 1 × 10 –7 joule (J) kiloton (kt) (TNT equivalent ) 4.184 × 10 12 joule (J) British...C kg –1 ) rad [absorbed dose] 1 × 10 –2 joule per kilogram (J kg –1 ) [gray (Gy)] rem [ equivalent and effective dose] 1 × 10–2 joule per kilogram...This “ non -governmental” association, with close ties to the Ministry of Foreign Affairs (MFA) and People’s Liberation Army (PLA), helped improve
NASA Astrophysics Data System (ADS)
Athar, Basit S.; Paganetti, Harald
2009-08-01
In this work we have simulated the absorbed equivalent doses to various organs distant to the field edge assuming proton therapy treatments of brain or spine lesions. We have used computational whole-body (gender-specific and age-dependent) voxel phantoms and considered six treatment fields with varying treatment volumes and depths. The maximum neutron equivalent dose to organs near the field edge was found to be approximately 8 mSv Gy-1. We were able to clearly demonstrate that organ-specific neutron equivalent doses are age (stature) dependent. For example, assuming an 8-year-old patient, the dose to brain from the spinal fields ranged from 0.04 to 0.10 mSv Gy-1, whereas the dose to the brain assuming a 9-month-old patient ranged from 0.5 to 1.0 mSv Gy-1. Further, as the field aperture opening increases, the secondary neutron equivalent dose caused by the treatment head decreases, while the secondary neutron equivalent dose caused by the patient itself increases. To interpret the dosimetric data, we analyzed second cancer incidence risks for various organs as a function of patient age and field size based on two risk models. The results show that, for example, in an 8-year-old female patient treated with a spinal proton therapy field, breasts, lungs and rectum have the highest radiation-induced lifetime cancer incidence risks. These are estimated to be 0.71%, 1.05% and 0.60%, respectively. For an 11-year-old male patient treated with a spinal field, bronchi and rectum show the highest risks of 0.32% and 0.43%, respectively. Risks for male and female patients increase as their age at treatment time decreases.
NASA Astrophysics Data System (ADS)
Ávila, O.; Torres-Ulloa, C. L.; Medina, L. A.; Trujillo-Zamudio, F. E.; de Buen, I. Gamboa; Buenfil, A. E.; Brandan, M. E.
2010-12-01
Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerología, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with 137Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrología, to known 137Cs gamma radiation air kerma. Radionuclides considered for this study are 131I, 18F, 67Ga, 99mTc, 111In, 201Tl and 137Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placed during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with 131I and 137Cs. High dose values were found at the waste storage room, outside corridor of 137Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the 137Cs brachytherapy corridor is equal to (18.51±0.02)×10-3 mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05±0.03)×10-3 mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).
The micro-structure of laminar premixed, atmospheric-pressure, fuel-rich flames of n-heptane/oxygen/argon has been studied at two equivalence ratios (C/O = 0.63 and C/O = 0.67). A heated quartz microprobe coupled to an online gas chromatography/mass spectrometry (HP 5890 Serie...
Models of Hematopoietic Dynamics Following Burn for Use in Combined Injury Simulations
2015-04-28
distribution is unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT The effects of thermal injury were incorporated into previously developed models that...per kilogram (C kg–1) absorbed dose (rad) 1 × 10–2 joule per kilogram (J kg–1§) equivalent and effective dose (rem) 1 × 10–2 joule per kilogram (J...Gy = 1 J kg–1). **The special name for the SI unit of equivalent and effective dose is the sievert (Sv). (1 Sv = 1 J kg–1). Table of Contents Table
A novel phosphorus biofertilizer based on cattle manure and phytases-nanoclay complexes
NASA Astrophysics Data System (ADS)
Blackburn, Daniel; Jorquera, Milko; Greiner, Ralf; Velasquez, Gabriela; Mora, María de la Luz
2013-04-01
Phytate and other phytase labile organic phosphorus (P) are abundant in both soils and manures. These recalcitrant forms of P accumulate in soils by their interaction with mineral particles. The aim of this work was to evaluate the potential of treating cattle manure with phytases stabilized in allophanic nanoclays, as a novel P biofertilization technology for crops grown in volcanic soils (Andisol). Two Andisols and two manures with contrasting inorganic Pcontent were used: Low P soil from Piedras Negras series (SPN-LP); High P soil from Freire Series (SF-HP); Low P Waste (WPN-LP); High P Waste (WF-HP). The used Andisols and manures were incubated with phytase-nanoclay complexes and the inorganic P was determined in the NaOH-EDTA and bicarbonate extracts. The WPN-LP was also inoculated with an alkaline β-propeller phytase (BPP) producing bacterium. The incubated SPN-LP and SPN-LP-WPN-LP mixture were evaluated for their P supplying capacity to wheat plants under greenhouse conditions. Our resultsindicated that the treatment of cattle manure with phytase stabilized in nanoclays resulted in a significant (P≤0.0.5) increase in the inorganic P. The use of phytase treated cattle manure increased 10% plant dry weight and 39% P concentration in wheat plants under greenhouse conditions, being equivalent to a P fertilizer dose of about 150 kg of P ha-1. In the case of low P cattle manure inoculated with BPP producing bacterium, inorganic P increased 10% in soil extracts (NaOH EDTA and Bicarbonate). However, the application of this treated manure did not result in a significant response to wheat growth and P acquisition. Our results suggest that this novel approach of incubating cattle manure with phytase stabilized in nanoclays enhances organic P cycling and P nutrition of plants grown under P-deficient soils.
Jin, Xingxing; Schwabe, Kerstin; Krauss, Joachim K; Alam, Mesbah
2016-04-01
The pathophysiological mechanisms leading to dyskinesias in Parkinson's disease (PD) after long-term treatment with levodopa remain unclear. This study investigates the neuronal firing characteristics of the entopeduncular nucleus (EPN), the rat equivalent of the human globus pallidus internus and output nucleus of the basal ganglia, and its coherence with the motor cortex (MCx) field potentials in the unilateral 6-OHDA rat model of PD with and without levodopa-induced dyskinesias (LID). 6-hydroxydopamine-lesioned hemiparkinsonian (HP) rats, 6-OHDA-lesioned HP rats with LID (HP-LID) rats, and naïve controls were used for recording of single-unit activity under urethane (1.4 g/kg, i.p) anesthesia in the EPN "on" and "off" levodopa. Over the MCx, the electrocorticogram output was recorded. Analysis of single-unit activity in the EPN showed enhanced firing rates, burst activity, and irregularity compared to naïve controls, which did not differ between drug-naïve HP and HP-LID rats. Analysis of EPN spike coherence and phase-locked ratio with MCx field potentials showed a shift of low (12-19 Hz) and high (19-30 Hz) beta oscillatory activity between HP and HP-LID groups. EPN theta phase-locked ratio was only enhanced in HP-LID compared to HP rats. Overall, levodopa injection had no stronger effect in HP-LID rats than in HP rats. Altered coherence and changes in the phase lock ratio of spike and local field potentials in the beta range may play a role for the development of LID.
NASA Technical Reports Server (NTRS)
Wilson, J. W.; Chun, S. Y.; Reginatto, M.; Hajnal, F.
1995-01-01
The Green's function for the transport of ions of high charge and energy is utilized with a nuclear fragmentation database to evaluate dose, dose equivalent, and RBE for C3H10T1/2 cell survival and neo-plastic transformation as function of depth in soft tissue. Such evaluations are useful to estimates of biological risk for high altitude aircraft, space operations, accelerator operations, and biomedical application.
NASA Astrophysics Data System (ADS)
Geng, Changran; Moteabbed, Maryam; Seco, Joao; Gao, Yiming; Xu, X. George; Ramos-Méndez, José; Faddegon, Bruce; Paganetti, Harald
2016-01-01
The goal of this work was to determine the scattered photon dose and secondary neutron dose and resulting risk for the sensitive fetus from photon and proton radiotherapy when treating a brain tumor during pregnancy. Anthropomorphic pregnancy phantoms with three stages (3-, 6-, 9-month) based on ICRP reference parameters were implemented in Monte Carlo platform TOPAS, to evaluate the scattered dose and secondary neutron dose and dose equivalent. To evaluate the dose equivalent, dose averaged quality factors were considered for neutrons. This study compared three treatment modalities: passive scattering and pencil beam scanning proton therapy (PPT and PBS) and 6-MV 3D conformal photon therapy. The results show that, for 3D conformal photon therapy, the scattered photon dose equivalent to the fetal body increases from 0.011 to 0.030 mSv per treatment Gy with increasing stage of gestation. For PBS, the neutron dose equivalent to the fetal body was significantly lower, i.e. increasing from 1.5 × 10-3 to 2.5 × 10-3 mSv per treatment Gy with increasing stage of gestation. For PPT, the neutron dose equivalent of the fetus decreases from 0.17 to 0.13 mSv per treatment Gy with the growing fetus. The ratios of dose equivalents to the fetus for a 52.2 Gy(RBE) course of radiation therapy to a typical CT scan of the mother’s head ranged from 3.4-4.4 for PBS, 30-41 for 3D conformal photon therapy and 180-500 for PPT, respectively. The attained dose to a fetus from the three modalities is far lower than the thresholds of malformation, severe mental retardation and lethal death. The childhood cancer excessive absolute risk was estimated using a linear no-threshold dose-response relationship. The risk would be 1.0 (95% CI: 0.6, 1.6) and 0.1 (95% CI: -0.01, 0.52) in 105 for the 9-month fetus for PBS with a prescribed dose of 52.2 Gy(RBE). The increased risks for PPT and photon therapy are about two and one orders of magnitude larger than that for PBS, respectively. We can conclude that a pregnant woman with a brain tumor could be treated with pencil beam scanning with acceptable risks to the fetus.
NASA Astrophysics Data System (ADS)
Kramer, R.; Khoury, H. J.; Vieira, J. W.; Kawrakow, I.
2007-11-01
Micro computed tomography (µCT) images of human spongiosa have recently been used for skeletal dosimetry with respect to external exposure to photon radiation. In this previous investigation, the calculation of equivalent dose to the red bone marrow (RBM) and to the bone surface cells (BSC) was based on five different clusters of micro matrices derived from µCT images of vertebrae, and the BSC equivalent dose for 10 µm thickness of the BSC layer was determined using an extrapolation method. The purpose of this study is to extend the earlier investigation by using µCT images from eight different bone sites and by introducing an algorithm for the direct calculation of the BSC equivalent dose with sub-micro voxel resolution. The results show that for given trabecular bone volume fractions (TBVFs) the whole-body RBM equivalent dose does not depend on bone site-specific properties or imaging parameters. However, this study demonstrates that apart from the TBVF and the BSC layer thickness, the BSC equivalent dose additionally depends on a so-called trabecular bone structure (TBS) effect, i.e. that the contribution of photo-electrons released in trabecular bone to the BSC equivalent dose also depends on the bone site-specific structure of the trabeculae. For a given bone site, the TBS effect is also a function of the thickness of the BSC layer, and it could be shown that this effect would disappear almost completely, should the BSC layer thickness be raised from 10 to 50 µm, according to new radiobiological findings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avila, O.; Torres-Ulloa, C. L.; Facultad de Ciencias, Universidad Nacional Autonoma de Mexico, AP 70-542, 04510, DF
2010-12-07
Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerologia, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with {sup 137}Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrologia, to known {sup 137}Cs gamma radiation air kerma. Radionuclides considered for this study are {sup 131}I, {sup 18}F, {sup 67}Ga, {sup 99m}Tc, {sup 111}In, {sup 201}Tl and {sup 137}Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placedmore » during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with {sup 131}I and {sup 137}Cs. High dose values were found at the waste storage room, outside corridor of {sup 137}Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the {sup 137}Cs brachytherapy corridor is equal to (18.51{+-}0.02)x10{sup -3} mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05{+-}0.03)x10{sup -3} mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).« less
10 CFR 835.402 - Individual monitoring.
Code of Federal Regulations, 2010 CFR
2010-01-01
... conditions, are likely to receive one or more of the following: (i) An effective dose of 0.1 rem (0.001 Sv) or more in a year; (ii) An equivalent dose to the skin or to any extremity of 5 rems (0.05 Sv) or more in a year; (iii) An equivalent dose to the lens of the eye of 1.5 rems (0.015 Sv) or more in a...
10 CFR 835.402 - Individual monitoring.
Code of Federal Regulations, 2013 CFR
2013-01-01
... conditions, are likely to receive one or more of the following: (i) An effective dose of 0.1 rem (0.001 Sv) or more in a year; (ii) An equivalent dose to the skin or to any extremity of 5 rems (0.05 Sv) or more in a year; (iii) An equivalent dose to the lens of the eye of 1.5 rems (0.015 Sv) or more in a...
10 CFR 835.402 - Individual monitoring.
Code of Federal Regulations, 2011 CFR
2011-01-01
... conditions, are likely to receive one or more of the following: (i) An effective dose of 0.1 rem (0.001 Sv) or more in a year; (ii) An equivalent dose to the skin or to any extremity of 5 rems (0.05 Sv) or more in a year; (iii) An equivalent dose to the lens of the eye of 1.5 rems (0.015 Sv) or more in a...
10 CFR 835.402 - Individual monitoring.
Code of Federal Regulations, 2012 CFR
2012-01-01
... conditions, are likely to receive one or more of the following: (i) An effective dose of 0.1 rem (0.001 Sv) or more in a year; (ii) An equivalent dose to the skin or to any extremity of 5 rems (0.05 Sv) or more in a year; (iii) An equivalent dose to the lens of the eye of 1.5 rems (0.015 Sv) or more in a...
10 CFR 835.402 - Individual monitoring.
Code of Federal Regulations, 2014 CFR
2014-01-01
... conditions, are likely to receive one or more of the following: (i) An effective dose of 0.1 rem (0.001 Sv) or more in a year; (ii) An equivalent dose to the skin or to any extremity of 5 rems (0.05 Sv) or more in a year; (iii) An equivalent dose to the lens of the eye of 1.5 rems (0.015 Sv) or more in a...
Dose estimation and dating of pottery from Turkey
NASA Astrophysics Data System (ADS)
Altay Atlıhan, M.; Şahiner, Eren; Soykal Alanyalı, Feriştah
2012-06-01
The luminescence method is a widely used technique for environmental dosimetry and dating archaeological, geological materials. In this study, equivalent dose (ED) and annual dose rate (AD) of an archaeological sample were measured. The age of the material was calculated by means of equivalent dose divided by the annual dose rate. The archaeological sample was taken from Antalya, Turkey. Samples were prepared by the fine grain technique and equivalent dose was found using multiple-aliquot-additive-dose (MAAD) and single aliquot regeneration (SAR) techniques. Also the short shine normalization-MAAD and long shine normalization-MAAD were applied and the results of the methods were compared with each other. The optimal preheat temperature was found to be 200 °C for 10 min. The annual doses of concentrations of the major radioactive isotopes were determined using a high-purity germanium detector and a low-level alpha counter. The age of the sample was found to be 510±40 years.
Thermosensitivity of a barosensitive Saccharomyces cerevisiae mutant obtained by UV mutagenesis
NASA Astrophysics Data System (ADS)
Shigematsu, Toru; Nomura, Kazuki; Nasuhara, Yusuke; Ikarashi, Kenta; Nagai, Gen; Hirayama, Masao; Hayashi, Mayumi; Ueno, Shigeaki; Fujii, Tomoyuki
2010-12-01
Using UV mutagenesis, a high pressure (HP)-sensitive (barosensitive) mutant of Saccharomyces cerevisiae was obtained. The mutant strain a924E1 showed a significant loss of viability at HP levels of 175 to 250 MPa at 20 °C compared with the parent strain. This strain also showed a significant loss of viability following heat treatment at 50-58 °C at 0.1 MPa. These results showed that the mutation caused a significant thermosensitivity as well as barosensitivity. The activation volume and activation energy values for the inactivation of strain a924E1 were equivalent to those of the parent strain. This suggested that the mechanism for the HP and thermal inactivation reaction of strain a924E1 was basically the same as that of the parent strain. Strain a924E1 showed no deficiency in growth and fermentation ability as well as auxotrophic property. Although the identification of the genetic sites of mutation introduced is underway, these phenotypes are favorable for the application of HP treatment and heat-assisted HP treatment on fermentation control.
Space radiation dose estimates on the surface of Mars
NASA Technical Reports Server (NTRS)
Simonsen, Lisa C.; Nealy, John E.; Townsend, Lawrence W.; Wilson, John W.
1990-01-01
The Langley cosmic ray transport code and the Langley nucleon transport code (BRYNTRN) are used to quantify the transport and attenuation of galactic cosmic rays (GCR) and solar proton flares through the Martian atmosphere. Surface doses are estimated using both a low density and a high density carbon dioxide model of the atmosphere which, in the vertical direction, provides a total of 16 g/sq cm and 22 g/sq cm of protection, respectively. At the Mars surface during the solar minimum cycle, a blood-forming organ (BFO) dose equivalent of 10.5 to 12 rem/yr due to galactic cosmic ray transport and attenuation is calculated. Estimates of the BFO dose equivalents which would have been incurred from the three large solar flare events of August 1972, November 1960, and February 1956 are also calculated at the surface. Results indicate surface BFO dose equivalents of approximately 2 to 5, 5 to 7, and 8 to 10 rem per event, respectively. Doses are also estimated at altitudes up to 12 km above the Martian surface where the atmosphere will provide less total protection.
Anthony, Jeremy; Esper, Gregory J; Ioachimescu, Adriana
2016-02-01
Hypothalamic-pituitary (HP) neurosarcoidosis (NS) accounts for 0.5 % cases of sarcoidosis and 1 % of HP masses. Correlative data on endocrine and neurological outcomes is lacking. Retrospective case series and literature review of presentation, treatment and outcome of HP NS. Our series includes 4 men, ages 34-59, followed for a median of 7.3 years (range 1.5-17). All had optic neuropathy, multiple pituitary hormone abnormalities (PHAs) and other organ involvement by sarcoidosis (lung, sino-nasal, brain/spine and facial nerve). Two patients had central diabetes insipidus and one impaired thirst with polydipsia. After treatment with high-dose glucocorticoids, optic neuropathy improved in one case and stabilized in the others. After treatment, HP lesions improved radiologically, but PHAs persisted in all cases. Review of four published series on HP NS in addition to ours yielded 46 patients, age 37 ± 11.8 years, 65 % male. PHAs consisted of anterior hypopituitarism (LH/FSH 88.8 %, TSH 67.4 %, GH 50.0 %, ACTH 48.8 %), hyperprolactinemia (48.8 %) and diabetes insipidus (65.2 %). PHAs were the first sign of disease in 54.3 % patients. Vision problems occurred in 28.3 % patients, but optic neuropathy was not well documented in previous series. Most patients (93.5 %) received high-dose glucocorticoids followed by taper; 50 % also received other immunomodulators, including methotrexate, mycophenolate mofetil, cyclosporine, azathioprine, infliximab and hydrochloroquine. Only 13 % patients showed improvement in PHAs. All-cause mortality was 8.7 %. HP NS is a serious disease requiring multidisciplinary treatment and lifelong follow-up. Prospective multicentric studies are needed to determine a more standardized approach to HP NS and outline predictors of disease outcome.
Walsh, Linda
2013-03-01
It has generally been assumed that the neutron and γ-ray absorbed doses in the data from the life span study (LSS) of the Japanese A-bomb survivors are too highly correlated for an independent separation of the all solid cancer risks due to neutrons and due to γ-rays. However, with the release of the most recent data for all solid cancer incidence and the increased statistical power over previous datasets, it is instructive to consider alternatives to the usual approaches. Simple excess relative risk (ERR) models for radiation-induced solid cancer incidence fitted to the LSS epidemiological data have been applied with neutron and γ-ray absorbed doses as separate explanatory covariables. A simple evaluation of the degree of independent effects from γ-ray and neutron absorbed doses on the all solid cancer risk with the hierarchical partitioning (HP) technique is presented here. The degree of multi-collinearity between the γ-ray and neutron absorbed doses has also been considered. The results show that, whereas the partial correlation between the neutron and γ-ray colon absorbed doses may be considered to be high at 0.74, this value is just below the level beyond which remedial action, such as adding the doses together, is usually recommended. The resulting variance inflation factor is 2.2. Applying HP indicates that just under half of the drop in deviance resulting from adding the γ-ray and neutron absorbed doses to the baseline risk model comes from the joint effects of the neutrons and γ-rays-leaving a substantial proportion of this deviance drop accounted for by individual effects of the neutrons and γ-rays. The average ERR/Gy γ-ray absorbed dose and the ERR/Gy neutron absorbed dose that have been obtained here directly for the first time, agree well with previous indirect estimates. The average relative biological effectiveness (RBE) of neutrons relative to γ-rays, calculated directly from fit parameters to the all solid cancer ERR model with both colon absorbed dose covariables, is 65 (95 %CI: 11; 170). Therefore, although the 95 % CI is quite wide, reference to the colon doses with a neutron weighting of 10 may not be optimal as the basis for the determination of all solid cancer risks. Further investigations into the neutron RBE are required, ideally based on the LSS data with organ-specific neutron and γ-ray absorbed doses for all organs rather than the RBE weighted absorbed doses currently provided. The HP method is also suggested for use in other epidemiological cohort analyses that involve correlated explanatory covariables.
Moslehi, A; Raisali, G
2017-11-01
To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tissue. Also, a few weight fractions of 3He are assumed to be added to the TE gas. The dose-equivalents are determined for 11 neutron energies between thermal and 14 MeV using the lineal energy distributions calculated by Geant4 simulation toolkit and also the lineal energy-based quality factors. The results show that by adding 0.04% of 3He to the TE gas in each cavity, an energy-independent dose-equivalent response within 30% uncertainty around a median value of 0.91 in the above energy range is achieved. It is concluded that after its construction, the studied microdosemeter can be used to measure the dose-equivalent of neutrons, favorably. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong
2013-01-01
For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13.
Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong
2013-01-01
For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13. PMID:23542764
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wroe, Andrew; Centre for Medical Radiation Physics, University of Wollongong, Wollongong; Clasie, Ben
2009-01-01
Purpose: Microdosimetric measurements were performed at Massachusetts General Hospital, Boston, MA, to assess the dose equivalent external to passively delivered proton fields for various clinical treatment scenarios. Methods and Materials: Treatment fields evaluated included a prostate cancer field, cranial and spinal medulloblastoma fields, ocular melanoma field, and a field for an intracranial stereotactic treatment. Measurements were completed with patient-specific configurations of clinically relevant treatment settings using a silicon-on-insulator microdosimeter placed on the surface of and at various depths within a homogeneous Lucite phantom. The dose equivalent and average quality factor were assessed as a function of both lateral displacement frommore » the treatment field edge and distance downstream of the beam's distal edge. Results: Dose-equivalent value range was 8.3-0.3 mSv/Gy (2.5-60-cm lateral displacement) for a typical prostate cancer field, 10.8-0.58 mSv/Gy (2.5-40-cm lateral displacement) for the cranial medulloblastoma field, 2.5-0.58 mSv/Gy (5-20-cm lateral displacement) for the spinal medulloblastoma field, and 0.5-0.08 mSv/Gy (2.5-10-cm lateral displacement) for the ocular melanoma field. Measurements of external field dose equivalent for the stereotactic field case showed differences as high as 50% depending on the modality of beam collimation. Average quality factors derived from this work ranged from 2-7, with the value dependent on the position within the phantom in relation to the primary beam. Conclusions: This work provides a valuable and clinically relevant comparison of the external field dose equivalents for various passively scattered proton treatment fields.« less
NASA Technical Reports Server (NTRS)
Summers, Geoffrey P.; Burke, Edward A.; Shapiro, Philip; Statler, Richard; Messenger, Scott R.; Walters, Robert J.
1994-01-01
It has been found useful in the past to use the concept of 'equivalent fluence' to compare the radiation response of different solar cell technologies. Results are usually given in terms of an equivalent 1 MeV electron or an equivalent 10 MeV proton fluence. To specify cell response in a complex space-radiation environment in terms of an equivalent fluence, it is necessary to measure damage coefficients for a number of representative electron and proton energies. However, at the last Photovoltaic Specialist Conference we showed that nonionizing energy loss (NIEL) could be used to correlate damage coefficients for protons, using measurements for GaAs as an example. This correlation means that damage coefficients for all proton energies except near threshold can be predicted from a measurement made at one particular energy. NIEL is the exact equivalent for displacement damage of linear energy transfer (LET) for ionization energy loss. The use of NIEL in this way leads naturally to the concept of 10 MeV equivalent proton fluence. The situation for electron damage is more complex, however. It is shown that the concept of 'displacement damage dose' gives a more general way of unifying damage coefficients. It follows that 1 MeV electron equivalent fluence is a special case of a more general quantity for unifying electron damage coefficients which we call the 'effective 1 MeV electron equivalent dose'.
Couto, José Guilherme; Bravo, Isabel; Pirraco, Rui
2011-09-01
The purpose of this work was the biological comparison between Low Dose Rate (LDR) and Pulsed Dose Rate (PDR) in cervical cancer regarding the discontinuation of the afterloading system used for the LDR treatments at our Institution since December 2009. In the first phase we studied the influence of the pulse dose and the pulse time in the biological equivalence between LDR and PDR treatments using the Linear Quadratic Model (LQM). In the second phase, the equivalent dose in 2 Gy/fraction (EQD(2)) for the tumor, rectum and bladder in treatments performed with both techniques was evaluated and statistically compared. All evaluated patients had stage IIB cervical cancer and were treated with External Beam Radiotherapy (EBRT) plus two Brachytherapy (BT) applications. Data were collected from 48 patients (26 patients treated with LDR and 22 patients with PDR). In the analyses of the influence of PDR parameters in the biological equivalence between LDR and PDR treatments (Phase 1), it was calculated that if the pulse dose in PDR was kept equal to the LDR dose rate, a small the-rapeutic loss was expected. If the pulse dose was decreased, the therapeutic window became larger, but a correction in the prescribed dose was necessary. In PDR schemes with 1 hour interval between pulses, the pulse time did not influence significantly the equivalent dose. In the comparison between the groups treated with LDR and PDR (Phase 2) we concluded that they were not equivalent, because in the PDR group the total EQD(2) for the tumor, rectum and bladder was smaller than in the LDR group; the LQM estimated that a correction in the prescribed dose of 6% to 10% was ne-cessary to avoid therapeutic loss. A correction in the prescribed dose was necessary; this correction should be achieved by calculating the PDR dose equivalent to the desired LDR total dose.
Bravo, Isabel; Pirraco, Rui
2011-01-01
Purpose The purpose of this work was the biological comparison between Low Dose Rate (LDR) and Pulsed Dose Rate (PDR) in cervical cancer regarding the discontinuation of the afterloading system used for the LDR treatments at our Institution since December 2009. Material and methods In the first phase we studied the influence of the pulse dose and the pulse time in the biological equivalence between LDR and PDR treatments using the Linear Quadratic Model (LQM). In the second phase, the equivalent dose in 2 Gy/fraction (EQD2) for the tumor, rectum and bladder in treatments performed with both techniques was evaluated and statistically compared. All evaluated patients had stage IIB cervical cancer and were treated with External Beam Radiotherapy (EBRT) plus two Brachytherapy (BT) applications. Data were collected from 48 patients (26 patients treated with LDR and 22 patients with PDR). Results In the analyses of the influence of PDR parameters in the biological equivalence between LDR and PDR treatments (Phase 1), it was calculated that if the pulse dose in PDR was kept equal to the LDR dose rate, a small the-rapeutic loss was expected. If the pulse dose was decreased, the therapeutic window became larger, but a correction in the prescribed dose was necessary. In PDR schemes with 1 hour interval between pulses, the pulse time did not influence significantly the equivalent dose. In the comparison between the groups treated with LDR and PDR (Phase 2) we concluded that they were not equivalent, because in the PDR group the total EQD2 for the tumor, rectum and bladder was smaller than in the LDR group; the LQM estimated that a correction in the prescribed dose of 6% to 10% was ne-cessary to avoid therapeutic loss. Conclusions A correction in the prescribed dose was necessary; this correction should be achieved by calculating the PDR dose equivalent to the desired LDR total dose. PMID:23346123
Hassan, Muhammad; Waheed, Muhammad Mohsin; Anjum, Muhammad Naeem
2016-01-01
To quantify the radiation dose enhancement in a human tissue-equivalent polymer gel impregnated with silver nanoparticles. The case-control study was conducted at the Bahawalpur Institute of Nuclear Medicine and Oncology, Bahawalpur, Pakistan, in January 2014. Silver nanoparticles used in this study were prepared by wet chemical method. Polymer gel was prepared by known quantity of gelatine, methacrylic acid, ascorbic acid, copper sulphate pentahydrate, hydroquinone and water. Different concentrations of silver nanoparticles were added to the gel during its cooling process. The gel was cooled in six plastic vials of 50ml each. Two vials were used as a control sample while four vials were impregnated with silver nanoparticles. After 22 hours, the vials were irradiated with gamma rays by aCobalt-60 unit. Radiation enhancement was assessed by taking magnetic resonance images of the vials. The images were analysed using Image J software. The dose enhancement factor was 24.17% and 40.49% for 5Gy and 10Gy dose respectively. The dose enhancement factor for the gel impregnated with 0.10mM silver nanoparticles was 32.88% and 51.98% for 5Gy and 10Gy dose respectively. The impregnation of a tissue-equivalent gel with silver nanoparticles resulted in dose enhancement and this effect was magnified up to a certain level with the increase in concentration of silver nanoparticles.
Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture.
Egger, Dominik; Spitz, Sarah; Fischer, Monica; Handschuh, Stephan; Glösmann, Martin; Friemert, Benedikt; Egerbacher, Monika; Kasper, Cornelia
2017-01-01
It is crucial but challenging to keep physiologic conditions during the cultivation of 3D cell scaffold constructs for the optimization of 3D cell culture processes. Therefore, we demonstrate the benefits of a recently developed miniaturized perfusion bioreactor together with a specialized incubator system that allows for the cultivation of multiple samples while screening different conditions. Hence, a decellularized bone matrix was tested towards its suitability for 3D osteogenic differentiation under flow perfusion conditions. Subsequently, physiologic shear stress and hydrostatic pressure (HP) conditions were optimized for osteogenic differentiation of human mesenchymal stem cells (MSCs). X-ray computed microtomography and scanning electron microscopy (SEM) revealed a closed cell layer covering the entire matrix. Osteogenic differentiation assessed by alkaline phosphatase activity and SEM was found to be increased in all dynamic conditions. Furthermore, screening of different fluid shear stress (FSS) conditions revealed 1.5 mL/min (equivalent to ∼10 mPa shear stress) to be optimal. However, no distinct effect of HP compared to flow perfusion without HP on osteogenic differentiation was observed. Notably, throughout all experiments, cells cultivated under FSS or HP conditions displayed increased osteogenic differentiation, which underlines the importance of physiologic conditions. In conclusion, the bioreactor system was used for biomaterial testing and to develop and optimize a 3D cell culture process for the osteogenic differentiation of MSCs. Due to its versatility and higher throughput efficiency, we hypothesize that this bioreactor/incubator system will advance the development and optimization of a variety of 3D cell culture processes. © 2017 S. Karger AG, Basel.
Radiation exposure for manned Mars surface missions
NASA Technical Reports Server (NTRS)
Simonsen, Lisa C.; Nealy, John E.; Townsend, Lawrence W.; Wilson, John W.
1990-01-01
The Langley cosmic ray transport code and the Langley nucleon transport code (BRYNTRN) are used to quantify the transport and attenuation of galactic cosmic rays (GCR) and solar proton flares through the Martian atmosphere. Surface doses are estimated using both a low density and a high density carbon dioxide model of the atmosphere which, in the vertical direction, provides a total of 16 g/sq cm and 22 g/sq cm of protection, respectively. At the Mars surface during the solar minimum cycle, a blood-forming organ (BFO) dose equivalent of 10.5 to 12 rem/yr due to galactic cosmic ray transport and attenuation is calculated. Estimates of the BFO dose equivalents which would have been incurred from the three large solar flare events of August 1972, November 1960, and February 1956 are also calculated at the surface. Results indicate surface BFO dose equivalents of approximately 2 to 5, 5 to 7, and 8 to 10 rem per event, respectively. Doses are also estimated at altitudes up to 12 km above the Martian surface where the atmosphere will provide less total protection.
fixme{background-color:#ff0}.container-fluid{padding:0;margin:0}.hp{font-family:Roboto," }.hp-hero-text{position:absolute;text-shadow:1px 1px 1px rgba(150,150,150,1)}.hp-hero h2{color:#fff}.hp -hero button{color:#e3e3e3;font-size:10px;background:transparent;border:none}.hp-hero button:hover,.hp
Hecksel, D; Anferov, V; Fitzek, M; Shahnazi, K
2010-06-01
Conventional proton therapy facilities use double scattering nozzles, which are optimized for delivery of a few fixed field sizes. Similarly, uniform scanning nozzles are commissioned for a limited number of field sizes. However, cases invariably occur where the treatment field is significantly different from these fixed field sizes. The purpose of this work was to determine the impact of the radiation field conformity to the patient-specific collimator on the secondary neutron dose equivalent. Using a WENDI-II neutron detector, the authors experimentally investigated how the neutron dose equivalent at a particular point of interest varied with different collimator sizes, while the beam spreading was kept constant. The measurements were performed for different modes of dose delivery in proton therapy, all of which are available at the Midwest Proton Radiotherapy Institute (MPRI): Double scattering, uniform scanning delivering rectangular fields, and uniform scanning delivering circular fields. The authors also studied how the neutron dose equivalent changes when one changes the amplitudes of the scanned field for a fixed collimator size. The secondary neutron dose equivalent was found to decrease linearly with the collimator area for all methods of dose delivery. The relative values of the neutron dose equivalent for a collimator with a 5 cm diameter opening using 88 MeV protons were 1.0 for the double scattering field, 0.76 for rectangular uniform field, and 0.6 for the circular uniform field. Furthermore, when a single circle wobbling was optimized for delivery of a uniform field 5 cm in diameter, the secondary neutron dose equivalent was reduced by a factor of 6 compared to the double scattering nozzle. Additionally, when the collimator size was kept constant, the neutron dose equivalent at the given point of interest increased linearly with the area of the scanned proton beam. The results of these experiments suggest that the patient-specific collimator is a significant contributor to the secondary neutron dose equivalent to a distant organ at risk. Improving conformity of the radiation field to the patient-specific collimator can significantly reduce secondary neutron dose equivalent to the patient. Therefore, it is important to increase the number of available generic field sizes in double scattering systems as well as in uniform scanning nozzles.
Kusakabe, Takato; Ozasa, Koji; Kobari, Shingo; Momota, Masatoshi; Kishishita, Natsuko; Kobiyama, Kouji; Kuroda, Etsushi; Ishii, Ken J
2016-06-08
Intranasal vaccination with inactivated influenza viral antigens is an attractive and valid alternative to currently available influenza (flu) vaccines; many of which seem to need efficient and safe adjuvant, however. In this study, we examined whether hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used pharmaceutical excipient to improve solubility and drug delivery, can act as a mucosal adjuvant for intranasal flu vaccines. We found that intranasal immunization of mice with hemagglutinin split- as well as inactivated whole-virion influenza vaccine with HP-β-CD resulted in secretion of antigen-specific IgA and IgGs in the airway mucosa and the serum as well. As a result, both HP-β-CD adjuvanted-flu intranasal vaccine protected mice against lethal challenge with influenza virus, equivalent to those induced by experimental cholera toxin-adjuvanted ones. Of note, intranasal use of HP-β-CD as an adjuvant induced significantly lower antigen-specific IgE responses than that induced by aluminum salt adjuvant. These results suggest that HP-β-CD may be a potent mucosal adjuvant for seasonal and pandemic influenza vaccine. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wade, D W; Trammel, B C; Dixit, B S
1979-02-01
Heat Pump Centered-Integrated Community Energy Systems (HP-ICES) show the promise of utilizing low-grade thermal energy for low-quality energy requirements such as space heating and cooling. The Heat Pump - Wastewater Heat Recovery (HP-WHR) scheme is one approach to an HP-ICES that proposes to reclaim low-grade thermal energy from a community's wastewater effluent. The concept of an HP-WHR system is developed, the potential performance and economics of such a system is evaluated and the potential for application is examined. A thermodynamic performance analysis of a hypothetical system projects an overall system coefficient of performance (C.O.P.) of from 2.181 to 2.264 formore » wastewater temperatures varying from 50/sup 0/F to 80/sup 0/F. Primary energy source savings from the implementation of this system is projected to be 5.014 QUADS, or the energy equivalent of 687 millions tons of coal, from 1980 to the year 2000. Economic analysis shows the HP-WHR scheme to be cost-competitive, on the basis of a net present value life cycle cost comparison, with conventional residential and light commercial HVAC systems.« less
Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2009-01-13
In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.« less
NASA Astrophysics Data System (ADS)
Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro
A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.
Protection efficiency of a standard compliant EUV reticle handling solution
NASA Astrophysics Data System (ADS)
He, Long; Lystad, John; Wurm, Stefan; Orvek, Kevin; Sohn, Jaewoong; Ma, Andy; Kearney, Patrick; Kolbow, Steve; Halbmaier, David
2009-03-01
For successful implementation of extreme ultraviolet lithography (EUVL) technology for late cycle insertion at 32 nm half-pitch (hp) and full introduction for 22 nm hp high volume production, the mask development infrastructure must be in place by 2010. The central element of the mask infrastructure is contamination-free reticle handling and protection. Today, the industry has already developed and balloted an EUV pod standard for shipping, transporting, transferring, and storing EUV masks. We have previously demonstrated that the EUV pod reticle handling method represents the best approach in meeting EUVL high volume production requirements, based on then state-of-the-art inspection capability at ~53nm polystyrene latex (PSL) equivalent sensitivity. In this paper, we will present our latest data to show defect-free reticle handling is achievable down to 40 nm particle sizes, using the same EUV pod carriers as in the previous study and the recently established world's most advanced defect inspection capability of ~40 nm SiO2 equivalent sensitivity. The EUV pod is a worthy solution to meet EUVL pilot line and pre-production exposure tool development requirements. We will also discuss the technical challenges facing the industry in refining the EUV pod solution to meet 22 nm hp EUVL production requirements and beyond.
Fan, Hong-Yun; Wang, Juan; Yan, Guo-Chao; Huo, Xiao-Hui; Mu, Li-Juan; Chu, Jian-Kun; Niu, Wei-Wei; Duan, Zhi-Ying; Ma, Jin-Cheng; Wang, Jing; Wang, Zhi-Yu
2013-03-01
The aim of this study was to observe the efficacy of clarithromycin-based triple therapy for Helicobacter pylori (Hp)-infected duodenal ulcer when combined with different pH levels of gastric juices. A total of 160 patients with Hp-infected duodenal ulcers were randomly allocated into two groups. Patients in the treatment group (n=80) were administered a 20-mg dose of omeprazole twice daily for 1 week and then the treatment and control groups (n=80) received therapy for Hp infection and duodenal ulcers. We observed the ulcer healing stage, the content of anti-Hp IgA in gastric juice and the Hp eradication rate before and after proton pump inhibitor therapy in the two groups. Results revealed that the Hp eradication rate in the treatment group was 93% compared with 81% in the control group, and the difference was statistically significant (P<0.05). The ulcer healing rate in the treatment group was 93%, compared with 70% in the control group (P<0.05). A positive linear correlation was observed between gastric pH and the content of anti-Hp IgA in gastric juice (P<0.05). Increasing gastric pH prior to anti-Hp therapy may be beneficial to the eradication of Hp and for promoting the healing of duodenal ulcers.
Clearance Rate and BP-ANN Model in Paraquat Poisoned Patients Treated with Hemoperfusion
Hu, Lufeng; Hong, Guangliang; Ma, Jianshe; Wang, Xianqin; Lin, Guanyang; Zhang, Xiuhua; Lu, Zhongqiu
2015-01-01
In order to investigate the effect of hemoperfusion (HP) on the clearance rate of paraquat (PQ) and develop a clearance model, 41 PQ-poisoned patients who acquired acute PQ intoxication received HP treatment. PQ concentrations were determined by high performance liquid chromatography (HPLC). According to initial PQ concentration, study subjects were divided into two groups: Low-PQ group (0.05–1.0 μg/mL) and High-PQ group (1.0–10 μg/mL). After initial HP treatment, PQ concentrations decreased in both groups. However, in the High-PQ group, PQ levels remained in excess of 0.05 μg/mL and increased when the second HP treatment was initiated. Based on the PQ concentrations before and after HP treatment, the mean clearance rate of PQ calculated was 73 ± 15%. We also established a backpropagation artificial neural network (BP-ANN) model, which set PQ concentrations before HP treatment as input data and after HP treatment as output data. When it is used to predict PQ concentration after HP treatment, high prediction accuracy (R = 0.9977) can be obtained in this model. In conclusion, HP is an effective way to clear PQ from the blood, and the PQ concentration after HP treatment can be predicted by BP-ANN model. PMID:25695058
Powell, D.C.; Aulerich, R.J.; Meadows, J.C.; Tillitt, D.E.; Stromborg, K.L.; Kubiak, T.J.; Giesy, J.P.; Bursian, S.J.
1997-01-01
White Leghorn chicken (Gallus domesticus) eggs were injected prior to incubation with one of four concentrations (0.001, 0.01, 0.1, and 1.0 egg-equivalent) of an extract derived from 1,000 double-crested cormorant (Phalacrocorax auritus) eggs collected at Spider Island adjacent to Green Bay in Lake Michigan. One egg-equivalent corresponded to the concentration of contaminants present in an average cormorant egg. This was approximately 322 pg toxic equivalents (TEQs)/g, ww egg with polychlorinatedbiphenyl congener 126 (3,3′,4,4′,5-pentachlorobiphenyl) accounting for over 70% of the TEQs. Injection of 1.0 egg-equivalent resulted in 77% mortality at hatch. The incidence of developmental abnormalities (structural defects or edema) was not affected by injection of the extract. Body weight gain of chicks was reduced in the 1.0 egg-equivalent dose group in the first, second, and third week's post-hatch. Relative brain weights were greater and relative bursa weights were less in the 1.0 egg-equivalent dose group than in the vehicle control at three weeks of age. There were no significant differences in the relative weights of the heart, liver, spleen, testes, or comb among treated and control birds.
Tayari, Masoumeh; Moosavi-Nejad, Zahra; Moosavi Nejad, Fatemeh; Rezaei-Tavirani, Mostafa; Dehghan Shasaltaneh, Marzieh
2011-01-01
Haptoglobin (Hp) is a mammalian serum glycoprotein showing a genetic polymorphism with three types, 1-1, 2-2 and 1-2. Hp appears to conserve the recycling of heme-iron by forming an essentially irreversible but non-covalent complex with hemoglobin which is released into the plasma by erythrocyte lysis. As an important consequence, Haptoglobin-Hemoglobin complex (Hp-Hb) shows considerable antioxidant property. In this study, antioxidant activity of Hp (2-2)-Hb complex on hydrogen peroxide has been studied and analyzed in the absence and presence of two beta-lactam antibiotics in-vitro. For this purpose, non-Michaelis behavior of peroxidase activity of Hp (2-2)-Hb complex was analyzed using Eadie-Hofstee, Clearance and Hill plots, in the absence and presence of pharmaceutical dose of ampicillin and coamoxiclav. The results have shown that peroxidase activity of Hp (2-2)-Hb complex is modulated via homotropic effect of hydrogen peroxide as an allostric substrate. On the other hand antioxidant property of Hp (2-2)-Hb complex increased via heterotropic effect of both antibiotics on the peroxidase activity of the complex. Both drugs also have mild effect on quality of homotropic property of the peroxidase activity of Hp (2-2)-Hb complex. Therefore, it can be concluded from our study that both beta-lactam antibiotics can increase peroxidase activity of Hp (2-2)-Hb complex via heterotropic effect. Thus, the two antibiotics (especially ampicillin) may help those individuals with Hp (2-2) phenotype to improve the Hp-Hb complex efficiency of removing hydrogen peroxide from serum under oxidative stress. This can be important in the individuals with phenotype Hp 2-2 who have less antioxidant activity relative to other phenotypes and are susceptible to cardiovascular disorders, as has been reported by other researchers.
Pinto, Avd; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Pérez, C A; Martinez, E F; Flório, F M; Basting, R T
The purpose of this study was to evaluate the calcium (Ca) and phosphorous (P) content in enamel bleached with high and low concentrations of hydrogen peroxide (HP) using Total Reflection X-Ray Fluorescence (TXRF) and colorimetric spectrophotometry (SPEC). Forty-eight sound human third molars were used. Their roots were embedded in polystyrene resin and immersed for seven days in an artificial saliva solution. Then they were distributed into six groups to receive the bleaching treatments. The agents of high HP concentration (for in-office use) evaluated were Whiteness HP Maxx/FGM (35% HP), Whiteness HP Blue/FGM (35% HP, 2% calcium gluconate), Pola Office+/SDI (37.5% HP, 5% potassium nitrate), and Opalescence Boost/Ultradent (38% HP, 1.1% ion fluoride, 3% potassium nitrate); these agents were applied to enamel in three sessions. The agents of low HP concentration (for home use) evaluated were Pola Day/SDI (9.5% HP) and White Class 10%/FGM (10% HP, potassium nitrate, calcium, fluoride), and these agents were applied for 14 days. Enamel microbiopsies were evaluated by TXRF and SPEC analysis before the bleaching treatment (baseline), during the treatment, and 14 days after the end of the treatment. For TXRF, the Kruskal-Wallis test showed that Ca and P were not influenced by agent (p>0.05). For SPEC, Pola Office+, Opalescence Boost, Pola Day, and White Class 10% caused a decrease of Ca over time; there was a significant decrease of P over time to Pola Office+ and White Class 10%. The Spearman test showed no correlation between the Ca (p=0.987; r 2 =-0.020) and P (p=0.728, r 2 =0.038) obtained by SPEC and TXRF. For TXRF and SPEC, changes in Ca and P during bleaching occurred independently of the HP concentration used.
Nnamani, Petra Obioma; Ugwu, Agatha Adaora; Ibezim, Emmanuel Chinedu; Kenechukwu, Franklin Chimaobi; Akpa, Paul Achile; Ogbonna, John-Dike Nwabueze; Obitte, Nicholas Chinedu; Odo, Amelia Ngozi; Windbergs, Maike; Lehr, Claus-Michael; Attama, Anthony Amaechi
The present study aimed to develop low-dose liquisolid tablets of two antimalarial drugs artemether-lumefantrine (AL) from a nanostructured lipid carrier (NLC) of lumefantrine (LUM) and estimate the potential of AL as an oral delivery system in malariogenic Wistar mice. LUM-NLCs were prepared by hot homogenization using Precirol ® ATO 5/Transcutol ® HP and tallow fat/Transcutol ® HP optimized systems containing 3:1 ratios of the lipids, respectively, as the matrices. LUM-NLC characteristics, including morphology, particle size, zeta potential, encapsulation efficiency, yield, pH-dependent stability, and interaction studies, were investigated. Optimized LUM-NLCs were mixed with artemether powder and other dry ingredients and the resultant powder evaluated for micromeritics. Subsequent AL liquisolid tablets were tested for in vitro drug release and in vivo antiplasmodial activity in mice infected with Plasmodium berghei berghei (NK 65). Results showed that optimized LUM-NLC were stable, spherical, polydispersed but nanometric. Percentage yield and encapsulation efficiency were ~92% and 93% for Precirol ® ATO 5/Transcutol ® HP batch, then 81% and 95% for tallow fat/Transcutol ® HP batch while LUM was amorphous in NLC matrix. In vitro AL release from liquisolid compacts revealed initial burst release and subsequent sustained release. Liquisolid tablet compacts formulated with Precirol ® ATO 5/Transcutol ® HP-AL4 achieved higher LUM release in simulated intestinal fluid (84.32%) than tallow fat/Transcutol ® HP-BL3 (77.9%). Non-Fickian (anomalous) diffusion and super case II transport were the predominant mechanisms of drug release. Equal parasitemia reduction was observed for both batches of tablet compacts (~92%), superior to the reduction obtained with commercial antimalarial formulations: Coartem ® tablets (86%) and chloroquine phosphate tablets (66%). No significant difference ( P <0.05) in parasite reduction between double (4/24 mg/kg) and single (2/12 mg/kg) strength doses of AL compacts was observed. Our result highlights that AL could be formulated in much lower doses (4/24 mg/kg), for once-in-two days oral administration to improve patient compliance, which is currently not obtainable with conventional AL dosage forms.
Nnamani, Petra Obioma; Ugwu, Agatha Adaora; Ibezim, Emmanuel Chinedu; Kenechukwu, Franklin Chimaobi; Akpa, Paul Achile; Ogbonna, John-Dike Nwabueze; Obitte, Nicholas Chinedu; Odo, Amelia Ngozi; Windbergs, Maike; Lehr, Claus-Michael; Attama, Anthony Amaechi
2016-01-01
The present study aimed to develop low-dose liquisolid tablets of two antimalarial drugs artemether–lumefantrine (AL) from a nanostructured lipid carrier (NLC) of lumefantrine (LUM) and estimate the potential of AL as an oral delivery system in malariogenic Wistar mice. LUM-NLCs were prepared by hot homogenization using Precirol® ATO 5/Transcutol® HP and tallow fat/Transcutol® HP optimized systems containing 3:1 ratios of the lipids, respectively, as the matrices. LUM-NLC characteristics, including morphology, particle size, zeta potential, encapsulation efficiency, yield, pH-dependent stability, and interaction studies, were investigated. Optimized LUM-NLCs were mixed with artemether powder and other dry ingredients and the resultant powder evaluated for micromeritics. Subsequent AL liquisolid tablets were tested for in vitro drug release and in vivo antiplasmodial activity in mice infected with Plasmodium berghei berghei (NK 65). Results showed that optimized LUM-NLC were stable, spherical, polydispersed but nanometric. Percentage yield and encapsulation efficiency were ~92% and 93% for Precirol® ATO 5/Transcutol® HP batch, then 81% and 95% for tallow fat/Transcutol® HP batch while LUM was amorphous in NLC matrix. In vitro AL release from liquisolid compacts revealed initial burst release and subsequent sustained release. Liquisolid tablet compacts formulated with Precirol® ATO 5/Transcutol® HP-AL4 achieved higher LUM release in simulated intestinal fluid (84.32%) than tallow fat/Transcutol® HP-BL3 (77.9%). Non-Fickian (anomalous) diffusion and super case II transport were the predominant mechanisms of drug release. Equal parasitemia reduction was observed for both batches of tablet compacts (~92%), superior to the reduction obtained with commercial antimalarial formulations: Coartem® tablets (86%) and chloroquine phosphate tablets (66%). No significant difference (P<0.05) in parasite reduction between double (4/24 mg/kg) and single (2/12 mg/kg) strength doses of AL compacts was observed. Our result highlights that AL could be formulated in much lower doses (4/24 mg/kg), for once-in-two days oral administration to improve patient compliance, which is currently not obtainable with conventional AL dosage forms. PMID:27932882
Sakakura, Kenichi; Roth, Austin; Ladich, Elena; Shen, Kai; Coleman, Leslie; Joner, Michael; Virmani, Renu
2015-02-01
The Paradise Ultrasound Renal Denervation System is a next-generation catheter-based device which was used to investigate whether the target ablation area can be controlled by changing ultrasound energy and duration to optimise nerve injury while preventing damage to the arterial wall. Five ultrasound doses were tested in a thermal gel model. Catheter-based ultrasound denervation was performed in 15 swine (29 renal arteries) to evaluate five different doses in vivo, and animals were euthanised at seven days for histopathologic assessment. In the gel model, the peak temperature was highest in the low power-long duration (LP-LD) dose, followed by the mid-low power-mid duration (MLP-MD) dose and the mid-high power-short duration (MHP-SD) dose, and lowest in the mid power-short duration (MP-SD) dose and the high power-ultra short duration (HP-USD) dose. In the animal study, total ablation area was significantly greater in the LP-LD group, followed by the MLP-MD group, and it was least in the HP-USD, MP-SD and MHP-SD groups (p=0.02). Maximum distance was significantly greater in the LP-LD group, followed by the MLP-MD group, the MHP-SD group, and the HP-USD group, and shortest in the MP-SD group (p=0.007). The short spare distance was not different among the five groups (p=0.38). Renal artery damage was minimal, while preserving significant nerve damage in all groups. The Paradise Ultrasound Renal Denervation System is a controllable system where total ablation area and depth of ablation can be optimised by changing ultrasound power and duration while sparing renal arterial tissue damage but allowing sufficient peri-arterial nerve damage.
Ying, Xixiang; Meng, Xiansheng; Wang, Siyuan; Wang, Dong; Li, Haibo; Wang, Bing; Du, Yang; Liu, Xun; Zhang, Wenjie; Kang, Tingguo
2012-01-01
A simple and sensitive HPLC method was developed to simultaneously determine three active compounds, vitexin-4″-O-glucoside (VG), vitexin-2″-O-rhamnoside (VR) and hyperoside (HP), in rat plasma after administering the hawthorn leaves extract (HLE). An HPLC assay with baicalin as the internal standard was carried out using a Phenomsil C₁₈ analytical column with UV detection at 332 nm. The mobile phase consisted of methanol-acetonitrile-tetrahydrofuran-1% glacial acetic acid (6 : 1.5 : 18.5 : 74, v/v/v/v). The calibration curves were linear over the range of 2.5-500, 0.2-25 and 0.25-12.5 µg mL⁻¹ for VG, VR and HP, respectively. The method was reproducible and reliable, with relative standard deviations of the intra- and inter-day precision between 1.2% and 13.2% for the analysis of the three analytes. The validated HPLC method herein described was successfully applied to the pharmacokinetic study of VG, VR and HP after oral administration of HLE to rats over the dose range of 2.5-10 mL kg⁻¹.
Malins, Alex; Kurikami, Hiroshi; Kitamura, Akihiro; Machida, Masahiko
2016-10-01
Calculations are reported for ambient dose equivalent rates [H˙*(10)] at 1 m height above the ground surface before and after remediating radiocesium-contaminated soil at wide and open sites. The results establish how the change in H˙*(10) upon remediation depends on the initial depth distribution of radiocesium within the ground, on the size of the remediated area, and on the mass per unit area of remediated soil. The remediation strategies considered were topsoil removal (with and without recovering with a clean soil layer), interchanging a topsoil layer with a subsoil layer, and in situ mixing of the topsoil. The results show the ratio of the radiocesium components of H˙*(10) post-remediation relative to their initial values (residual dose factors). It is possible to use the residual dose factors to gauge absolute changes in H˙*(10) upon remediation. The dependency of the residual dose factors on the number of years elapsed after fallout deposition is analyzed when remediation parameters remain fixed and radiocesium undergoes typical downward migration within the soil column.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Moteabbed, M
Purpose: To determine the scattered neutron dose and the resulting risk for a fetus from proton therapy for brain tumors during pregnancy. Methods: Using the Monte Carlo platform TOPAS, the ICRP reference parameters based anthropomorphic pregnancy phantoms for three stages (3-, 6-, 9-month) were applied to evaluate the scattered neutron dose and dose equivalent. To calculate the dose equivalent, organ specific linear energy transfer (LET) based quality factor was used. Treatment plans from both passive scattering (PS) and pencil beam scanning (PBS) methods were considered in this study. Results: For pencil beam scanning, the neutron dose equivalent in the softmore » tissue of the fetus increases from 1.53x10−{sup 3} to 2.84x10−{sup 3} mSv per treatment Gy with increasing stage of gestation. This is due to scattered neutrons from the patient as the main contaminant source in PBS and a decrease in distance between the soft tissue of the fetus and GTV with increasing stage of gestation. For passive scattering, neutron dose equivalent to the soft tissue of the fetus shows a decrease from 0.17 to 0.13 mSv per treatment Gy in different stages, while the dose to the brain shows little difference around 0.18 mSv per treatment Gy because scattered neutrons from the treatment head contribute predominantly in passive scattering. Conclusion: The results show that the neutron dose to the fetus assuming a prescribed dose of 52.2 Gy is negligible for PBS, and is comparable to the scattered dose (0–10 mSv) from a head and neck CT scan for PS. It can be concluded that the dose to fetus is far lower than the thresholds of malformation, SMR and lethal death. The excess relative risk of childhood cancer induction would be increased by 0.48 and 0.103 using the Oxford Survey of Childhood Cancers and Japanese atomic model, respectively. Changran Geng is supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087)« less
Orta De Velásquez, M T; Yáñez-Noguez, I; Jiménez-Cisneros, B; Luna Pabello, V M
2008-11-01
This paper evaluates the efficacy of hydrogen peroxide (HP) and peracetic acid (PAA) in the disinfection of an Advanced Primary Treatment (APT) effluent, and how said disinfection capacities can be enhanced by combining the oxidants with copper (Cu2+) and silver (Ag). The treatment sequence consisted of APT (adding chemicals to water to remove suspended solids by coagulation and flocculation), followed by disinfection with various doses of HP, HP+Cu2+, HP+Ag, PAA and PAA+Ag. Microbiological quality was determined by monitoring concentrations of fecal coliforms (FC), pathogenic bacteria (PB) and helminth eggs (HE) throughout the sequence. The results revealed that APT effluent still contains very high levels of bacteria as the treatment only removes 1-2 log of FC and PB, but the reduction in the number of viable helminth eggs was 83%. Subsequent disinfection stages demonstrated that both HP+Cu2+ and HP+Ag have a marked disinfection capacity for bacteria (3.9 and 3.4 log-inactivation, respectively). Peracetic acid on its own was already extremely efficient at disinfecting for bacteria, and the effect was enhanced when combining PAA with silver (PAA+Ag). The best result for HE removal was achieved by combining PAA with silver (PAA+Ag) at doses of 20 + 2.0 mg l(-1), respectively. The study concluded that the PAA+Ag and HP+Ag combinations were good alternatives for APT effluent disinfection, because the disinfected effluents met the standards in NOM-001-SEMARNAT-1996, Mexico's regulation governing the microbiological quality required in treated wastewater destined for unrestricted reuse in agricultural irrigation (< or =1 helminths per litre). Combining either of these disinfection treatments with a primary method such as APT, therefore, offers an effective and practical way of reducing the health risks normally associated with the reuse of wastewaters.
Kwon, S R; Pallavi, Fnu; Shi, Y; Oyoyo, U; Mohraz, A; Li, Y
Whitening efficacy has been related to hydrogen peroxide (HP) diffusion into tooth structure. However, little information is available relating rheological properties to whitening efficacy. The purpose was to evaluate the whitening efficacy and HP penetration level of a 10% HP gel at three different viscosities and to compare them to a strip delivery system. Extracted molars (n=120) were randomly assigned into five groups (n=24/ group): NC_MED (negative control; median): medium viscosity gel without HP; LOW: 10% HP gel (low viscosity experimental gel, Ultradent Products Inc); MED: 10% HP gel (medium viscosity experimental gel, Ultradent); HIGH: 10% HP gel (high viscosity gel, Ultradent); and CWS: Crest 3D Whitestrips 1-Hour Express (Procter & Gamble). All teeth were subjected to five 60-minute whitening sessions. Instrumental color measurements were performed at baseline (T 0 ), and 1-day after each application (T 1 -T 5 ), and 1-month after whitening (T 6 ). HP penetration was estimated with leucocrystal violet and horseradish peroxidase. A Kruskal-Wallis test and post hoc Bonferroni test were performed to assess the difference in tooth color change and HP penetration among the groups (α=0.05). Hydrogen peroxide penetration levels and overall color changes at T 6 were 0.24 μg/mL / 2.80; 0.48 μg/mL / 8.48; 0.44 μg/mL / 7.72; 0.35 μg/mL / 8.49; 0.36 μg/mL / 7.30 for groups NC, LOW, MED, HIGH, and CWS, respectively. There was a significant difference for HP penetration, while there was no significant difference among the four experimental groups for tooth color change. Rheological properties should be considered when developing new whitening formulations.
Zhao, Yue; Ruan, Xiangyan; Mueck, Alfred O
2017-06-01
There are still open questions about ovulation induction in clomiphene citrate-(CC)-resistant infertile women. Especially little is known about efficacy and safety of letrozole (LTZ) combined with low-dose highly purified human menopausal gonadotropin (Hp-HMG) in women with polycystic ovary syndrome (PCOS). Prospective, single-arm single-center trial in 200 infertile PCOS patients refractory for at least three CC-treatment cycles. Women with hyperandrogenism took Diane-35 for at least 3 months. All patients got LTZ on day 3 for 5 d in combination with Hp-HMG, starting with 75 IU from cycle day 7 and maintained for up to 3 d. The maximum dose was 150 IU. Primary end-points were ongoing and clinical pregnancy rate, secondary end-points mono-follicular development, ovulation rate, OHSS, multiple pregnancy and early pregnancy loss. Major safety end-point was the incidence of adverse events. Within 395 cycles the ongoing pregnancy rate was 28.24%, for cycles 35.23%, for patients 68%. The rate of ovulation per cycle was 97.7%, percentage of mono-follicular development 70.9%. No severe OHSS, multiple pregnancy, local or systemic side effects were seen. LTZ combined with low-dose Hp-HMG is an effective and safe choice for reducing hyperstimulation and increasing pregnancy rate in CC-resistant women with PCOS.
Kinetic release of hydrogen peroxide from different whitening products.
da Silva Marques, Duarte Nuno; Silveira, Joao Miguel; Marques, Joana Rita; Amaral, Joao Almeida; Guilherme, Nuno Marques; da Mata, António Duarte
2012-01-01
The objective of this in vitro study was to evaluate the kinetics of hydrogen peroxide (HP) release from five different bleaching products: VivaStyle® 10% fitted tray gel, VivaStyle® 30% in-office bleaching gel, VivaStyle® Paint-On Plus paint-on bleaching varnish, Opalescence PF® 10% carbamide peroxide gel and Trèswhite Supreme 10% HP gel. Each product was firstly titrated for its HP content by a described method. HP release kinetics was assessed by a modified spectrophotometric technique. One sample t test was performed to test for differences between the manufacturers' claimed HP concentrations and the titrated HP content in the whitening products. Analysis of variance plus Tamhane's post hoc tests and Pearson correlation analysis were used as appropriate. Values of P < 0.05 were taken as significant. Titrated HP revealed an increased content when compared to the manufacturer's specifications for all the products tested (P < 0.05), although only products from one manufacturer produced significantly higher results. All products presented a significant (P < 0.05) and sustained release of HP. However, the product with paint-on cellulose-based matrix resulted in significantly (P < 0.05) faster kinetics when compared to other products tested. These results are consistent with manufacturers' reduced recommended application times. The results of this study suggest that modifying the matrix composition may be a viable alternative to HP concentration increase, since this may result in faster release kinetics without exposure to high HP concentrations.
A study of the Armstrong Whitworth swing beam engine for automotive application
NASA Technical Reports Server (NTRS)
1983-01-01
The introduction of ceramics to those parts suffering high thermal loading was successfully demonstrated, and there is no question that the 100 kw (134 hp) naturally aspirated engine of the future will be developed to produce up to 300 kw (402 hp) by the application of turbocharging or its equivalent. However, at the 60 - 80 kw (80 - 107 hp) size needed for the economic automotive engine, scaling down the 300 kw (402 hp) is beset by the laws of scale. The conventional four stroke diesel was not shown to be successful at the small high speed engine size. The opposed piston two stroke engine does not suffer the same laws of scale and engines in the low power range have already been marketed successfully. The half liter/cylinder Armstrong Whitworth Swing Beam Engine is the latest to be designed with the automotive market in mind. Its low noise structure and balanced linkage system coupled with advantages for easy start and potential use of low grade fuels, derived from its variable compression ratio and slow piston motion, qualifies it for the application.
Pediatric Phantom Dosimetry of Kodak 9000 Cone-beam Computed Tomography.
Yepes, Juan F; Booe, Megan R; Sanders, Brian J; Jones, James E; Ehrlich, Ygal; Ludlow, John B; Johnson, Brandon
2017-05-15
The purpose of the study was to evaluate the radiation dose of the Kodak 9000 cone-beam computed tomography (CBCT) device for different anatomical areas using a pediatric phantom. Absorbed doses resulting from maxillary and mandibular region three by five cm CBCT volumes of an anthropomorphic 10-year-old child phantom were acquired using optical stimulated dosimetry. Equivalent doses were calculated for radiosensitive tissues in the head and neck area, and effective dose for maxillary and mandibular examinations were calculated following the 2007 recommendations of the International Commission on Radiological Protection (ICRP). Of the mandibular scans, the salivary glands had the highest equivalent dose (1,598 microsieverts [μSv]), followed by oral mucosa (1,263 μSv), extrathoracic airway (pharynx, larynx, and trachea; 859 μSv), and thyroid gland (578 μSv). For the maxilla, the salivary glands had the highest equivalent dose (1,847 μSv), followed closely by oral mucosa (1,673 μSv), followed by the extrathoracic airway (pharynx, larynx, and trachea; 1,011 μSv) and lens of the eye (202 μSv). Compared to previous research of the Kodak 9000, completed with the adult phantom, a child receives one to three times more radiation for mandibular scans and two to 10 times more radiation for maxillary scans.
Fleury, Agnes; Sastre, Patricia; Sciutto, Edda; Correia, Silvia; Monedero, Alejandro; Toledo, Andrea; Hernandez, Maricela; Harrison, Leslie J S; Parkhouse, R Michael E
2016-10-27
A lateral flow assay (LFA) for the diagnosis and monitoring of extraparenchymal neurocysticercosis, has been developed. The assay is based on the use of the monoclonal antibody HP10, and when applied to cerebrospinal fluid, correctly identified 34 cases of active extraparenchymal neurocysticercosis, but was negative with 26 samples from treated and cured neurocysticercosis patients and with 20 samples from unrelated neurological diseases. There was complete agreement between the HP10 Ag-ELISA results and the HP10-LFA. The HP10-LFA thus has utility for diagnosis and treatment of extraparenchymal neurocysticercosis, frequently a more dangerous form of the infection. Copyright © 2016. Published by Elsevier Inc.
Sartor, O; Bowers, C Y; Chang, D
1985-03-01
His-DTrp-Ala-Trp-DPhe-Lys-NH2 (GH-RP-6) is a synthetic hexapeptide that specifically releases GH both in vivo and in vitro in pituitary incubates. In this study, for the first time, GH-RP-6 was studied in primary pituitary cell monolayer culture. Parallel studies were performed with human pancreatic GH-releasing factor-44 (hpGRF-44). Culture conditions optimal for GH-RP-6 were not optimal for hpGRF-44. Both peptides released GH in a dose- and time-dependent manner. In this assay system, the ED50 for GH-RP-6 was 9 nM, and the ED50 for hp-GRF-44 was 1.6 nM. Calcium-blocking agents inhibited the GH responses of both peptides as well as basal GH release. Pretreatment with GH-RP-6 decreased the subsequent response to both GH-RP-6 and hpGRF-44. hpGRF-44 down regulated itself but not GH-RP-6. Rat sera potentiated the GH response of hpGRF-44 but not that of GH-RP-6. GH-RP-6 and hpGRF-44 GH responses were additive. These results suggest that GH-RP-6 and hpGRF-44 stimulate GH release via different somatotroph receptors.
Long-term parenteral administration of 2-hydroxypropyl-β-cyclodextrin causes bone loss.
Kantner, Ingrid; Erben, Reinhold G
2012-07-01
Cyclodextrins are oligosaccharides which are used in the pharmaceutical industry and research as vehicles for application of apolar substances such as steroids. The aim of this study was to examine the long-term effects of parenteral administration of 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) on bone. Sham-operated (SHAM) or ovariectomized (OVX) adult rats were subcutaneously injected with physiological saline, 50, or 200 mg/kg HP-β-CD daily. After 4 months, body weight in OVX rats and uterine weight in SHAM rats were significantly lower after administration of 200 mg/kg HP-β-CD, relative to vehicle controls. At 200 mg/kg, HP-β-CD was hepatotoxic as measured by increased serum transaminases, and reduced serum albumin. Moreover, 200 mg/kg HP-β-CD led to decreased vertebral and tibial bone mineral density (BMD), and to cortical thinning at the tibial shaft. Bone loss in HP-β-CD-treated rats was associated with increased bone resorption as measured by increased renal deoxypyridinoline excretion. Although 50 mg/kg HP-β-CD was devoid of overt signs of organ toxicity and did not impair BMD, bone resorption was already increased. In summary, subcutaneous long-term administration of HP-β-CD at a daily dose of 200 mg/kg led to increased bone resorption and subsequent bone loss. Minor alterations in bone metabolism were also seen at 50 mg/kg.
Kim, Junghoe; Kim, Yong-Hwan; Lee, Jong-Hwan
2013-02-07
Alzheimer's disease (AD) is characterized by structural atrophies in the hippocampus (HP) and aberrant patterns of functional connectivities (FC) between the hippocampus and the rest of the brain. However, the relationship between cortical atrophy levels and corresponding degrees of aberrant FC patterns has not been systematically examined. In this study, we investigated whether there was an explicit link between structural abnormalities and corresponding functional aberrances associated with AD using structural and functional magnetic resonance imaging (fMRI) data. To this end, brain regions with cortical atrophies that are associated with AD were identified in the HP in the left (L) and right (R) hemispheres using structural MRI data from volume analyses (p<0.03 for L-HP; p<0.04 for R-HP) and voxel-based morphometry analyses (p<4×10(-4) for L-HP; p<2×10(-3) for R-HP). Aberrantly reduced FC levels between the HP (with atrophy) and precuneus were also consistently observed in fMRI data from AD than HC brains that were analyzed by the Pearson's correlation coefficients (p<3×10(-4) for L-HP; and p<8×10(-5) for R-HP). In addition, the substantial negative FC levels from the HC brains between the precuneus and post central gyrus (PoCG) without structural atrophy were also significantly diminished from the AD brains (p<5×10(-5) for L-PoCG; and p<6×10(-5) for R-PoCG). The effect sizes of these aberrant FC levels associated with AD were greater than that of cortical atrophy levels when comparing using normalized Z score and Cohen's d measures, which indicates that an aberrant FC level may precede cortical atrophy. Copyright © 2012 Elsevier B.V. All rights reserved.
β-blocker dosage and outcomes after acute coronary syndrome.
Allen, Jason E; Knight, Stacey; McCubrey, Raymond O; Bair, Tami; Muhlestein, Joseph Brent; Goldberger, Jeffrey J; Anderson, Jeffrey L
2017-02-01
Although β-blockers increase survival in acute coronary syndrome (ACS) patients, the doses used in trials were higher than doses used in practice, and recent data do not support an advantage of higher doses. We hypothesized that rates of major adverse cardiac events (MACE), all-cause death, myocardial infarction, and stroke are equivalent for patients on low-dose and high-dose β-blocker. Patients admitted to Intermountain Healthcare with ACS and diagnosed with ≥70% coronary stenosis between 1994 and 2013 were studied (N = 7,834). We classified low dose as ≤25% and high dose as ≥50% of an equivalent daily dose of 200 mg of metoprolol. Multivariate analyses were used to test association between low-dose versus high-dose β-blocker dosage and MACE at 0-6 months and 6-24 months. A total of 5,287 ACS subjects were discharged on β-blockers (87% low dose, 12% high dose, and 1% intermediate dose). The 6-month MACE outcomes rates for the β-blocker dosage (low versus high) were not equivalent (P = .18) (hazard ratio [HR] = 0.76; 95% CI, 0.52-1.10). However, subjects on low-dose β-blocker therapy did have a significantly decreased risk of myocardial infarction for 0-6 months (HR = 0.53; 95% CI, 0.33-0.86). The rates of MACE events during the 6-24 months after presentation with ACS were equivalent for the 2 doses (P = .009; HR = 1.03 [95% CI, 0.70-1.50]). In ACS patients, rates of MACE for high-dose and low-dose β-blocker doses are similar. These findings question the importance of achieving a high dose of β-blocker in ACS patients and highlight the need for further investigation of this clinical question. Copyright © 2016 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (KW) (3,000 horsepower (HP)) and a displacement of less than 10 liters per cylinder to the... ICE with a maximum engine power greater than 2,237 KW (3,000 HP) and a displacement of less than 10... 2,237 KW (3,000 HP) and a displacement of less than 10 liters per cylinder to the certification...
Code of Federal Regulations, 2013 CFR
2013-07-01
... (KW) (3,000 horsepower (HP)) and a displacement of less than 10 liters per cylinder to the... ICE with a maximum engine power greater than 2,237 KW (3,000 HP) and a displacement of less than 10... 2,237 KW (3,000 HP) and a displacement of less than 10 liters per cylinder to the certification...
Code of Federal Regulations, 2014 CFR
2014-07-01
... (KW) (3,000 horsepower (HP)) and a displacement of less than 10 liters per cylinder to the... ICE with a maximum engine power greater than 2,237 KW (3,000 HP) and a displacement of less than 10... 2,237 KW (3,000 HP) and a displacement of less than 10 liters per cylinder to the certification...
Code of Federal Regulations, 2012 CFR
2012-07-01
... (KW) (3,000 horsepower (HP)) and a displacement of less than 10 liters per cylinder to the... ICE with a maximum engine power greater than 2,237 KW (3,000 HP) and a displacement of less than 10... 2,237 KW (3,000 HP) and a displacement of less than 10 liters per cylinder to the certification...
Code of Federal Regulations, 2010 CFR
2010-07-01
... (KW) (3,000 horsepower (HP)) and a displacement of less than 10 liters per cylinder to the... ICE with a maximum engine power greater than 2,237 KW (3,000 HP) and a displacement of less than 10... 2,237 KW (3,000 HP) and a displacement of less than 10 liters per cylinder to the certification...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Schuemann, J
Purpose: To determine the neutron contamination from the aperture in pencil beam scanning during proton therapy. Methods: A Monte Carlo based proton therapy research platform TOPAS and the UF-series hybrid pediatric phantoms were used to perform this study. First, pencil beam scanning (PBS) treatment pediatric plans with average spot size of 10 mm at iso-center were created and optimized for three patients with and without apertures. Then, the plans were imported into TOPAS. A scripting method was developed to automatically replace the patient CT with a whole body phantom positioned according to the original plan iso-center. The neutron dose equivalentmore » was calculated using organ specific quality factors for two phantoms resembling a 4- and 14-years old patient. Results: The neutron dose equivalent generated by the apertures in PBS is 4–10% of the total neutron dose equivalent for organs near the target, while roughly 40% for organs far from the target. Compared to the neutron dose equivalent caused by PBS without aperture, the results show that the neutron dose equivalent with aperture is reduced in the organs near the target, and moderately increased for those organs located further from the target. This is due to the reduction of the proton dose around the edge of the CTV, which causes fewer neutrons generated in the patient. Conclusion: Clinically, for pediatric patients, one might consider adding an aperture to get a more conformal treatment plan if the spot size is too large. This work shows the somewhat surprising fact that adding an aperture for beam scanning for facilities with large spot sizes reduces instead of increases a potential neutron background in regions near target. Changran Geng is supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087)« less
NASA Astrophysics Data System (ADS)
Kholodenko, Arkady L.; Kauffman, Louis H.
2018-03-01
Huygens triviality - a concept invented by Jacques Hadamard - describes an equivalence class connecting those 2nd order partial differential equations which are transformable into the wave equation. In this work it is demonstrated, that the Schrödinger equation with the time-independent Hamiltonian belongs to such an equivalence class. The wave equation is the equation for which Huygens' principle (HP) holds. The HP was a subject of confusion in both physics and mathematics literature for a long time. Not surprisingly, the role of this principle was obscured from the beginnings of quantum mechanics causing some theoretical and experimental misunderstandings. The purpose of this work is to bring the full clarity into this topic. By doing so, we obtained a large amount of new results related to uses of Lie sphere geometry, of twistors, of Dupin cyclides, of null electromagnetic fields, of AdS-CFT correspondence, of Penrose limits, of geometric algebra, etc. in physical problems ranging from the atomic to high energy physics and cosmology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Y; Shahnazi, K; Wang, W
Purpose: Ion beams have an unavoidable lateral spread due to nuclear interactions interacting with the air and monitoring systems. To minimize this spread, the distance between the nozzle and the patient should be kept as small as possible.The purpose of this work was to determine the impact of the target-to-nozzle distance reduction on the secondary neutron dose equivalent in proton and carbon ion radiotherapy. Methods: In this study, abdominal and head phantoms were scanned with our CT scanner. Cubical targets with side lengths of 3 cm to 10 cm and 1 cm to 5 cm were drawn in the abdominalmore » and head phantoms respectively. Two intensity-modulated plans were made for each phantom and ion. The first of these plans placed the target at the isocenter while the other shifted the phantom 30 cm towards the nozzle. The plans at both phantom locations were optimized to provide identical dose coverage to the PTVs.Secondary neutron dose equivalent at 50 cm lateral to the center of target. Results: The neutron dose equivalent was higher for the larger field size from 0.25µSv per Gy (RBE) to 72µSv per Gy (RBE). The neutron dose equivalent was smaller when the phantom was placed at the upstream target location versus at the isocenter location by 8.9% to 10.4% and 11.0% to 22.1% for proton plans of the abdominal and head phantoms respectively. Differences for carbon plans with different target-to-nozzle locations were less than 3% for both phantoms. Conclusion: A reduction of target-to-nozzle distance can lead to benefits for proton radiotherapy. In this study, a reduction of secondary neutron dose equivalent was found for proton plans with a smaller target-to-nozzle distance. A greater impact was found for a head phantom with a smaller field size; however, a reduction of the target-to-nozzle distance had little effect for carbon therapy.« less
de la Peña, Amparo; Seger, Mary; Rave, Klaus; Heinemann, Lutz; Silverman, Bernard; Muchmore, Douglas B
2009-09-01
In order to assess pharmacokinetic (PK) and glucodynamic (GD) attributes relevant to the end user of an inhaled insulin, this study examined the exposure and GD effect of doses of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) by combining capsules of different strengths in healthy subjects. Fifty-nine healthy, nonsmoking, male or female subjects with normal pulmonary function were enrolled in an open-label, randomized, crossover study. Subjects underwent up to five euglycemic glucose clamp procedures, separated by 5-18 days. The five AIR insulin treatments tested included one 6 unit-equivalent (U-eq) capsule containing 2.6 mg of insulin, three 2 U-eq (0.9 mg) capsules (2.7 mg total), one 10 U-eq (3.9 mg) capsule, one 6 U-eq capsule plus two 2 U-eq capsules (4.4 mg total), and two 10 U-eq capsules (7.8 mg total). Samples for PK and GD assessments were taken up to 10 h post-dose. Based on both PK (area under the curve from time 0 to time of return to baseline and maximum concentration) and GD (total amount of glucose infused and maximum glucose infusion rate) responses, administration of a 6 U-eq capsule was equivalent to three 2 U-eq capsules; 90% confidence intervals for the ratios were contained within the interval (0.8, 1.25). Similarly, both overall exposure and glucodynamic response after administration of a 10 U-eq capsule were comparable to the 6 U-eq plus two 2 U-eq capsule combination. AIR insulin exhibited PK dose proportionality and dose-dependent increases in GD responses over the 2.6-7.8 mg dose range. AIR insulin exhibited dose strength interchangeability and dose proportionality after single-dose administration in healthy subjects.
Chemin, K; Rezende, M; Loguercio, A D; Reis, A; Kossatz, S
To evaluate the risk for and intensity of tooth sensitivity and color change of at-home dental bleaching with 4% and 10% hydrogen peroxide (HP). For this study, 78 patients were selected according to the inclusion and exclusion criteria and randomized into two groups: HP 4 (White Class 4%, FGM) and HP 10 (White Class 10%, FGM). In both groups, the at-home bleaching was performed for a period of 30 minutes twice a day for two weeks. The color was assessed by Vita Classical, Vita Bleachedguide 3D-MASTER and spectrophotometer Vita Easyshade (Vita Zahnfabrik) at baseline, during bleaching (first and second weeks) and after bleaching (one month). Patients recorded their tooth sensitivity using a numeric rating scale (0-4) and visual analog scale (0-10). Data from color change (DeltaE data) was submitted to two-way analysis of variance. The color change data in Delta SGU from the two shade guide units were compared with the Mann Whitney test. The risk of tooth sensitivity was evaluated by χ 2 test and the intensity of tooth sensitivity from both scales was evaluated by a Mann-Whitney test (α=0.05). The absolute risk and intensity of tooth sensitivity was higher in the group that used HP 10 than the one that used HP 4. Data from change in the number of shade guide units and color variation after one month of bleaching for both groups showed significant whitening, with no difference between groups. At-home bleaching is effective with 4% and 10% HP concentrations, but 10% HP increased the absolute risk and intensity of tooth sensitivity during at-home bleaching.
NASA Astrophysics Data System (ADS)
Nisauf, T. A.; Wibowo, W. E.; Pawiro, S. A.
2017-07-01
This study was done to evaluate the gamma index for registering between the planar of dose planning and the measurement of EBT film. The treatment plan was simulated for 5 patients using Fan Beam Computerized Tomography (FBCT) modality, Philips Pinnacle planning system, 6 MV photon energy, 50 segments IMRT technique, and calculation grid resolution (CGR) of 0.2 cm. Gamma Index (GI) evaluation was done with criteria of dose difference (DD) of 2 %, dose to agreement (DTA) of 2 mm and dose difference (DD) of 5 % DTA of 3 mm, SAD 100 cm, depth of 5 cm and 10 cm of the phantom. The result shows that GI for homogeneous material is greater than for inhomogeneous material with discrepancy to previous work is about 1.98 % for homogeneous material (depth 5 cm) and 2.05 % (depth 10 cm) while it was found of 2.98 % for inhomogeneous material (equivalent depth 5 cm) and 4.59 % (equivalent depth 10 cm).
Ribeiro, Irma Cláudia Saboya; Kubrusly, Luiz Fernandao; Nassif, Paulo Afonso Nunes; Ribeiro, Patrícia Fernanda Saboya; Veras, Rodrigo de Oliveira; Neppel, Aline
2016-01-01
The influence of Helicobacter pylori (HP) in inflammatory disorders of the digestive mucosa has been the subject of several studies since socioeconomic, personal and environmental factors were implicated in the bacteria transmission. To correlate the inflammatory endoscopic findings with HP infection and the onset of mucosal diseases mucous of the upper digestive tract. Comparative observational study, in which were collected data from 2247 patients who underwent upper endoscopy and biopsies for HP with urease test. The patients were divided into two groups: HP+ and HP- (control) in which endoscopic findings were observed for the following changes: esophagitis, esophageal ulcer, gastritis, erosive gastritis, gastric ulcer, bulboduodenitis, bulbar ulcer and without disease. As for esophagitis, there was little disparity in the distribution favorable to HP+ group (HP+ =67.11% and HP- =69.89%) and esophageal ulcer (HP+ =0% and HP- =0, 21%). Gastritis was favorable to HP- group (HP+ =78.34% and HP- =73.63%), as well as erosive gastritis (HP+ = 67,11% and HP- = 64,55%), in bulboduodenitis (HP+ =1,87% and HP- 1,23%), in gastric ulcer (HP+ =2,14% and HP- =2,03%) and in the absence of alterations in the HP+ group (4.81%) with the HP- control group (6,30%), in which there was little disproportion in favor of HP- group, but without statistical significance. As for the bulbar ulcer (HP +=10.16% and HP- =4.48%), there was statistically significant (p=0.00001). There is no difference between HP+ and HP- groups in inflammatory changes in endoscopic gastroduodenal mucosa, except for the relationship between HP and bulbar ulcer. A influência do Helicobacter pylori (HP) nas alterações inflamatórias das mucosas digestivas tem sido objeto de vários estudos uma vez que fatores socioeconômicos, pessoais e ambientais são implicados na transmissão da bactéria, facilitando-a. Relacionar os achados inflamatórios endoscópicos com a infecção pelo HP e o aparecimento de doenças mucosas do trato digestivo alto. Estudo observacional comparativo, o qual foram coletados dados de 2247 pacientes submetidos à endoscopia digestiva alta e biópsias para HP com teste de urease. Os pacientes foram divididos em dois grupos: HP+ e o controle HP-dentro dos quais foram observados os achados endoscópicos referentes às seguintes alterações: esofagite, úlcera esofágica, gastrite, gastrite erosiva, úlcera gástrica, bulboduodenite, úlcera bulbar e sem doença. Quanto à esofagite, observou-se pequena desproporção na distribuição, favorável ao grupo HP+ (HP+ =67,11% e HP- =69,89%) bem como na úlcera esofágica (HP+ =0% e HP- =0,21%). Na gastrite foi favorável ao grupo HP- (HP+ =78.34% e HP- =73.63%), assim como na gastrite erosiva (HP+ = 67,11% e HP- = 64,55%), na bulboduodenite (HP+ = 1,87% e HP- 1,23%), na úlcera gástrica (HP+ =2,14% e HP- =2,03%) e na ausência de alterações no grupo HP+ (4.81%) com o grupo controle HP- (6,30%), nos quais há pequena desproporção favorável ao grupo HP-, porém, sem significância estatística. Já quanto à úlcera bulbar (HP+ =10,16% e HP- =4,48%), houve significância estatística (p=0,00001). Não há diferenciação entre os grupos HP+ e HP- nas alterações endoscópicas inflamatórias na mucosa gastroduodenal, exceto para a relação entre HP e úlcera bulbar.
Assessment of out-of-field absorbed dose and equivalent dose in proton fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clasie, Ben; Wroe, Andrew; Kooy, Hanne
2010-01-15
Purpose: In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may increase the risk of radiation-induced secondary cancer and interact with electronic devices in the treatment room. The authors implement a Monte Carlo model of this dose deposited outside passively scattered fields and compare it to measurements, determine the out-of-field equivalent dose, and estimate the change in the dose if the same target volumes were treated with an active beam scanning technique. Methods: Measurements are done with a thimble ionization chamber and the Wellhofer MatriXX detector insidemore » a Lucite phantom with field configurations based on the treatment of prostate cancer and medulloblastoma. The authors use a GEANT4 Monte Carlo simulation, demonstrated to agree well with measurements inside the primary field, to simulate fields delivered in the measurements. The partial contributions to the dose are separated in the simulation by particle type and origin. Results: The agreement between experiment and simulation in the out-of-field absorbed dose is within 30% at 10-20 cm from the field edge and 90% of the data agrees within 2 standard deviations. In passive scattering, the neutron contribution to the total dose dominates in the region downstream of the Bragg peak (65%-80% due to internally produced neutrons) and inside the phantom at distances more than 10-15 cm from the field edge. The equivalent doses using 10 for the neutron weighting factor at the entrance to the phantom and at 20 cm from the field edge are 2.2 and 2.6 mSv/Gy for the prostate cancer and cranial medulloblastoma fields, respectively. The equivalent dose at 15-20 cm from the field edge decreases with depth in passive scattering and increases with depth in active scanning. Therefore, active scanning has smaller out-of-field equivalent dose by factors of 30-45 in the entrance region and this factor decreases with depth. Conclusions: The dose deposited immediately downstream of the primary field, in these cases, is dominated by internally produced neutrons; therefore, scattered and scanned fields may have similar risk of second cancer in this region. The authors confirm that there is a reduction in the out-of-field dose in active scanning but the effect decreases with depth. GEANT4 is suitable for simulating the dose deposited outside the primary field. The agreement with measurements is comparable to or better than the agreement reported for other implementations of Monte Carlo models. Depending on the position, the absorbed dose outside the primary field is dominated by contributions from primary protons that may or may not have scattered in the brass collimating devices. This is noteworthy as the quality factor of the low LET protons is well known and the relative dose risk in this region can thus be assessed accurately.« less
Shah, Bhranti S; Chahine, Nadeen O
2018-02-01
Dynamic hydrostatic pressure (HP) loading can modulate nucleus pulposus (NP) cell metabolism, extracellular matrix (ECM) composition, and induce transformation of notochordal NP cells into mature phenotype. However, the effects of varying cell density and dynamic HP magnitude on NP phenotype and metabolism are unknown. This study examined the effects of physiological magnitudes of HP loading applied to bovine NP cells encapsulated within three-dimensional (3D) alginate beads. Study 1: seeding density (1 M/mL versus 4 M/mL) was evaluated in unloaded and loaded (0.1 MPa, 0.1 Hz) conditions. Study 2: loading magnitude (0, 0.1, and 0.6 MPa) applied at 0.1 Hz to 1 M/mL for 7 days was evaluated. Study 1: 4 M/mL cell density had significantly lower adenosine triphosphate (ATP), glycosaminoglycan (GAG) and collagen content, and increased lactate dehydrogenase (LDH). HP loading significantly increased ATP levels, and expression of aggrecan, collagen I, keratin-19, and N-cadherin in HP loaded versus unloaded groups. Study 2: aggrecan expression increased in a dose dependent manner with HP magnitude, whereas N-cadherin and keratin-19 expression were greatest in low HP loading compared to unloaded. Overall, the findings of the current study indicate that cell seeding density within a 3D construct is a critical variable influencing the mechanobiological response of NP cells to HP loading. NP mechanobiology and phenotypic expression was also found to be dependent on the magnitude of HP loading. These findings suggest that HP loading and culture conditions of NP cells may require complex optimization for engineering an NP replacement tissue.
Influence of surfactants on the effectiveness of bleaching gels.
Caneppele, Taciana Marco Ferraz; Torres, Carlos Rocha Gomes
2011-02-01
This study evaluated the influence of surfactants on the effectiveness of 35% hydrogen peroxide (HP) and 10% carbamide peroxide (CP) bleaching gels. One hundred and forty bovine teeth were used, which were stained by immersion in a coffee, red wine, and tobacco mixture for 7 days. At the end of this process, the color measurement at baseline was taken with the Vita Easyshade spectrophotometer. The teeth were divided into seven groups: (a) negative control (NC), (b) positive control for HP (PC-35), (c) HP + Tween 20 (T20-35), (d) HP + laurel sodium sulfate (LSS-35), (e) positive control for CP (PC-10), (f) CP + Tween 20 (T20-10), and (g) CP + laurel sodium sulfate (LSS-10). Group NC was kept in artificial saliva for 21 days. Groups PC-35, T20-35, and LSS 35 received three applications of bleaching gel for 10 min; the process was repeated after 7 days. Groups PC-10, T20-10, and LSS-10 received the gel for 8 h per day for 14 days. After the bleaching process, the final color was measured. The analysis of variance and Tukey tests showed statistically significant differences for the parameters of ∆L, ∆b, and ∆E of the HP gels with surfactant and positive control group (PC-35). Within the limits of this in vitro study, the addition of surfactants to HP bleaching gel increased the bleaching effectiveness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shekel, E; Epstein, D; Levin, D
2016-06-15
Purpose: To determine the tissue equivalence of a brass mesh bolus (RPD) in the setting of a reconstructed chest wall irradiation Methods: We measured breast skin dose delivered by a tangential field plan on an anthropomorphic phantom using Mosfet and nanoDot (Landauer) dosimeters in five different locations on the breast. We also measured skin dose using no bolus, 5mm and 10 mm superflab bolus. In the Eclipse treatment planning system (Varian, Palo Alto, CA) we calculated skin dose for different bolus thicknesses, ranging from 0 to 10 mm, in order to evaluate which calculation best matches the brass mesh measurements,more » as the brass mesh cannot be simulated due to artefacts.Finally, we measured depth dose behavior with the brass mesh bolus to verify that the bolus does not affect the dose to the breast itself beyond the build-up region. Results: Mosfet and nanoDot measurements were consistent with each other.As expected, skin dose measurements with no bolus had the least agreement with Eclipse calculation, while measurements for 5 and 10 mm agreed well with the calculation despite the difficulty in conforming superflab bolus to the breast contour. For the brass mesh the best agreement was for 3 mm bolus Eclipse calculation. For Mosfets, the average measurement was 90.8% of the expected dose, and for nanoDots 88.33% compared to 83.34%, 88.64% and 93.94% (2,3 and 5 mm bolus calculation respectively).The brass mesh bolus increased skin dose by approximately 25% but there was no dose increase beyond the build-up region. Conclusion: Brass mesh bolus is most equivalent to a 3 mm bolus, and does not affect the dose beyond the build-up region. The brass mesh cannot be directly calculated in Eclipse, hence a 3mm bolus calculation is a good reflection of the dose response to the brass mesh bolus.« less
Dynamic culturing of cartilage tissue: the significance of hydrostatic pressure.
Correia, Cristina; Pereira, Ana L; Duarte, Ana R C; Frias, Ana M; Pedro, Adriano J; Oliveira, João T; Sousa, Rui A; Reis, Rui L
2012-10-01
Human articular cartilage functions under a wide range of mechanical loads in synovial joints, where hydrostatic pressure (HP) is the prevalent actuating force. We hypothesized that the formation of engineered cartilage can be augmented by applying such physiologic stimuli to chondrogenic cells or stem cells, cultured in hydrogels, using custom-designed HP bioreactors. To test this hypothesis, we investigated the effects of distinct HP regimens on cartilage formation in vitro by either human nasal chondrocytes (HNCs) or human adipose stem cells (hASCs) encapsulated in gellan gum (GG) hydrogels. To this end, we varied the frequency of low HP, by applying pulsatile hydrostatic pressure or a steady hydrostatic pressure load to HNC-GG constructs over a period of 3 weeks, and evaluated their effects on cartilage tissue-engineering outcomes. HNCs (10×10(6) cells/mL) were encapsulated in GG hydrogels (1.5%) and cultured in a chondrogenic medium under three regimens for 3 weeks: (1) 0.4 MPa Pulsatile HP; (2) 0.4 MPa Steady HP; and (3) Static. Subsequently, we applied the pulsatile regimen to hASC-GG constructs and varied the amplitude of loading, by generating both low (0.4 MPa) and physiologic (5 MPa) HP levels. hASCs (10×10(6) cells/mL) were encapsulated in GG hydrogels (1.5%) and cultured in a chondrogenic medium under three regimens for 4 weeks: (1) 0.4 MPa Pulsatile HP; (2) 5 MPa Pulsatile HP; and (3) Static. In the HNC study, the best tissue development was achieved by the pulsatile HP regimen, whereas in the hASC study, greater chondrogenic differentiation and matrix deposition were obtained for physiologic loading, as evidenced by gene expression of aggrecan, collagen type II, and sox-9; metachromatic staining of cartilage extracellular matrix; and immunolocalization of collagens. We thus propose that both HNCs and hASCs detect and respond to physical forces, thus resembling joint loading, by enhancing cartilage tissue development in a frequency- and amplitude-dependant manner.
NASA Technical Reports Server (NTRS)
Badhwar, G. D.; Cucinotta, F. A.; Wilson, J. W. (Principal Investigator)
1998-01-01
A matched set of five tissue-equivalent proportional counters (TEPCs), embedded at the centers of 0 (bare), 3, 5, 8 and 12-inch-diameter polyethylene spheres, were flown on the Shuttle flight STS-81 (inclination 51.65 degrees, altitude approximately 400 km). The data obtained were separated into contributions from trapped protons and galactic cosmic radiation (GCR). From the measured linear energy transfer (LET) spectra, the absorbed dose and dose-equivalent rates were calculated. The results were compared to calculations made with the radiation transport model HZETRN/NUCFRG2, using the GCR free-space spectra, orbit-averaged geomagnetic transmission function and Shuttle shielding distributions. The comparison shows that the model fits the dose rates to a root mean square (rms) error of 5%, and dose-equivalent rates to an rms error of 10%. Fairly good agreement between the LET spectra was found; however, differences are seen at both low and high LET. These differences can be understood as due to the combined effects of chord-length variation and detector response function. These results rule out a number of radiation transport/nuclear fragmentation models. Similar comparisons of trapped-proton dose rates were made between calculations made with the proton transport model BRYNTRN using the AP-8 MIN trapped-proton model and Shuttle shielding distributions. The predictions of absorbed dose and dose-equivalent rates are fairly good. However, the prediction of the LET spectra below approximately 30 keV/microm shows the need to improve the AP-8 model. These results have strong implications for shielding requirements for an interplanetary manned mission.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kok, H. Petra, E-mail: H.P.Kok@amc.uva.nl; Crezee, Johannes; Franken, Nicolaas A.P.
2014-03-01
Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy{sup −1}) and β (Gy{sup −2}) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normalmore » tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment modalities.« less
Furlan, Isabella Spinardi; Bridi, Enrico Coser; Amaral, Flávia Lucisano Botelho do; França, Fabiana Mantovani Gomes; Turssi, Cecilia Pedroso; Basting, Roberta Tarkany
2017-01-01
The aim of this in vitro study was to evaluate enamel microhardness following bleaching treatments using either high- or low-concentration hydrogen peroxide (HP) agents containing calcium and/or fluoride. Sixty enamel blocks were bleached with 1 of 6 different bleaching agents (n = 10). The high-concentration HP agents were Whiteness HP Maxx (35% HP), Whiteness HP Blue (35% HP, 2% calcium gluconate), Pola Office+ (37.5% HP, 5% potassium nitrate), and Opalescence Boost (38% HP, 1.1% fluoride ion, 3% potassium nitrate). The low-concentration HP agents evaluated were Pola Day (9.5% HP) and White Class (10% HP, potassium nitrate, calcium, fluoride). High-concentration agents were applied in 3 sessions, whereas low-concentration agents were applied for 14 days. Knoop microhardness measurements were taken on the surface of the enamel before bleaching, at various timepoints during bleaching, and 14 days after the final bleaching treatment. The 2-way analysis of variance test showed that microhardness values were significantly influenced by the bleaching agent (P < 0.001) and application time (P < 0.001). The Tukey test showed that enamel bleached with Whiteness HP Maxx or White Class presented lower microhardness values than did the enamel treated with the remaining products. There was a reduction in micro-hardness values up to the end of the treatment. The results showed that the composition, concentration, and application protocol for each bleaching agent influenced the enamel microhardness values in that the microhardness decreased over time, regardless of the agent used or the addition of calcium and/or fluoride.
Extensions to the Beta Secondary Standard BSS 2
NASA Astrophysics Data System (ADS)
Behrens, R.; Buchholz, G.
2011-11-01
Since several years, the irradiation facility for beta radiation, the Beta Secondary Standard BSS 2 developed at PTB, has been in worldwide use for the performance of irradiations with calibrated beta sources. Due to recent developments in eye tumor therapy, in eye lens dosimetry, and in soft- and hardware technology, several extensions have been added to the BSS 2. These extensions are described in this paper: 1. The possibility of using a 106Ru/106Rh beta source was added as this radionuclide is often used in tumor therapy. 2. The (small) contribution due to photon radiation was included in the dose (rate) reported by the BSS 2, as this was missing in the past. 3. The quantity personal dose equivalent at a depth of 3 mm, Hp(3), was implemented due to recent findings on the radio sensitivity of the eye lens regarding cataract induction and the subsequent lowering of the dose limit from 150 mSv down to 20 mSv per year; 4. The correction for ambient conditions (air temperature, pressure, and relative humidity) was improved in order to adequately handle the quantity Hp(3) and in order to extend the range of use beyond 25°C. 5. A checksum test was added to the software to secure the calibration data against (un)intended changes. 6. The connection of the PC and the BSS 2 has been changed to a network interface (TCP/IP) in order to be able to use up-to-date computers not containing a parallel and a serial port. 7. A rod phantom was added in order to make sure the mechanical set-up is of high quality. All these extensions have been implemented in the PTB's BSS 2 model. The routine implementation of extension 1 is still under investigation by the manufacturer. The commercially available BSS 2 will contain extensions 2 to 6 starting approximately in 2012, while extension 7 has already been incorporated since 2011. Extensions 2 to 4 will also be available for old BSS 2 versions via a software update, starting approximately at the beginning of 2012. Extension 6 will be available via hardware change by the manufacturer.
Whiting, S J; Anderson, D J; Weeks, S J
1997-05-01
An acute load test was used to test the influence of dietary factors on urinary calcium excretion. In study 1, 10 fasting premenopausal women consumed test meals providing a moderate amount of protein (MP; 23 g), MP plus 23 mmol KHCO3 (MP+K), MP plus 23 mmol NaCl (MP+Na), and a high amount of protein (HP; 53 g), HP plus 70 mmol KHCO3 (HP+K), and HP plus 70 mmol NaCl (HP+Na). Protein was casein:lactalbumin (80:20), except for the treatments with added sodium chloride, to which only casein was added. In study 2, the effects of HP and HP plus 50 mmol KHCO3 (HP+K) were compared with those of MP or MP plus 7.5 mmol phosphate (MP+Pi), equaling the additional phosphate of HP, in 10 adult men. Subjects completed all treatments in random order. In study 1, the peak of calcium excretion was at 3 h for all treatments, except for HP+K, which indicated an acute hypocalciuric effect of potassium. Unexpectedly, there was no hypercalciuric effect of adding sodium chloride, nor was urine sodium increased. In study 2, calcium excretion was significantly higher with HP than with MP+Pi but not with MP at 3 h, indicating an acute hypercalciuric effect of protein alone. A hypocalciuric effect of potassium (HP+K compared with HP) but not of phosphate (MP compared with MP+Pi) was seen. An acute load test measuring changes 3 h postload was appropriate for examining the calciuric effects of protein and potassium bicarbonate, but not those of sodium chloride or phosphate in adults.
NASA Astrophysics Data System (ADS)
Lin, Yung-Chieh; Lee, Chung-Chi; Chao, Tsi-Chian; Tsai, Hui-Yu
2017-11-01
Neutron production is a concern in proton therapy, particularly in scattering proton beam delivery systems. Despite this fact, little is known about the effects of secondary neutron exposure around wobbling scattered proton treatment nozzles. The objective of this study was to estimate the neutron dose level resulting from the use of a wobbling scattered proton treatment unit. We applied the Monte Carlo method for predict the ambient neutron dose equivalent, H*(10), per absorbed dose at the treatment isocenter, D, in the proton therapy center of Chang Gung Memorial Hospital, Linkou, Taiwan. For a 190-MeV proton beam, H* (10) / D values typically decreased with the distance from the isocenter, being 1.106 mSv/Gy at the isocenter versus 0.112 mSv/Gy at a distance of 150 cm from the isocenter. The H* (10) / D values generally decreased as the neutron receptors moved away from the isocenter, and increased when the angle from the initial beam axis increased. The ambient neutron dose equivalents were observed to be slightly lower in the direction of multileaf collimator movement. For radiation protection, the central axis of a proton-treated patient is suggested to be at the 0° angle of the beam. If the beam direction at the 90° angle is necessary, the patient axis is suggested to be along with the direction of MLC movement. Our study provides the neutron dose level and neutron energy fluence for the first wobbling proton system at the proton therapy center of Chang Gung Memorial Hospital.
Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M.
2016-01-01
Purpose To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. Methods As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Results Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = < .004). No significant differences were detected concerning the modalities’ specificities (with values between P = .98). Raters' confidence was higher in RED-MDCT and RED-CBCT compared to radiography (P < .001). Conclusion The diagnostic accuracy of RED-MDCT and RED-CBCT for wrist fractures proved to be similar and in some parts even higher compared to radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run. PMID:27788215
Metal-templated synthesis of macrocyclic (triphosphine)molybdenum complexes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diel, B.N.; Brandt, P.F.; Haltiwanger, R.C.
1989-07-12
Reaction of CH{sub 2}=CHCH{sub 2}PH{sub 2}, CH{sub 2}=CHCH{sub 2}CH{sub 2}PH{sub 2}, and CH{equivalent to}CCH{sub 2}PPH{sub 2} with (mesitylene)Mo(CO){sub 3} or (cycloheptatriene)Mo(CO){sub 3} yields the complexes (CH{sub 2}=CHCH{sub 2}PH{sub 2}){sub 3} (1), (CH{sub 2}=CHCH{sub 2}CH{sub 2}PH{sub 2}){sub 3}Mo(CO){sub 3} (2), and (CH{equivalent to}CCH{sub 2}PH{sub 2}){sub 3}Mo(CO){sub 3}, (3), respectively. Reaction of CH{sub 2}=CHCH{sub 2}PH{sub 2} and CH{equivalent to}CCH{sub 2}PH{sub 2} with cis-(piperidine){sub 2}Mo(CO){sub 4} yields cis-(CH{sub 2}=CHCH{sub 2}PH{sub 2}){sub 2}Mo(CO){sub 4} (4) and cis-(CH{equivalent to}CCH{sub 2}PH{sub 2}){sub 2}Mo(CO){sub 4} (5). Free-radical-initiated cyclooligomerization of 1 and 2 yields the triligated macrocyclic secondary-phosphine complexes fac-(HP(CH{sub 2}){sub 3}){sub 3}Mo(CO){sub 3} (6) and fac-(HP-(CH{sub 2}){submore » 4}){sub 3}Mo(CO){sub 3} (7). Under similar conditions, reaction of 4 yields an acyclic diphosphine complex characterized tentatively as cis-(H{sub 2}P(CH{sub 2}){sub 3}PH(CH{sub 2}CH=CH{sub 2}))Mo(CO){sub 4} (8). Compounds 1-7 and 10 have been characterized by spectral ({sup 31}P, {sup 13}C, and {sup 1}H, NMR and IR and mass) data. 6 has been characterized in the solid state by single-crystal x-ray analysis, and the results are reported. {sup 31}P NMR spectra studies of the cyclooligomerization of 1 show the partially cyclized intermediates formed prior to 6. The macrocyclic complexes 6 and 7 are kinetically stable, showing no sign of ligand displacement in reactions with pH{sub 3}P, PF{sub 3}, KCN, or P(OMe){sub 3}. 44 refs., 4 figs., 4 tabs.« less
The effects of levetiracetam on neural tube development in the early stage of chick embryos.
Guvenc, Yahya; Dalgic, Ali; Billur, Deniz; Karaoglu, Derya; Aydin, Sevim; Daglioglu, Ergun; Ozdol, Cagatay; Nacar, Osman Arikan; Yildirim, Ali Erdem; Belen, Deniz
2013-01-01
This study aimed to investigate the effects of a new generation antiepileptic agent, levetiracetam, on the neural tube development in a chick embryo model that corresponds to the first month of vertebral development in mammals. Forty-five Atabey® breed fertilized chicken eggs with no specific pathogens were randomly divided into 5 groups. All of the eggs were incubated at 37.8±2°C and 60±5 % relative humidity in an incubator. Group A was control group. The other eggs were applied physiological saline and drugs at a volume of 10 μL by the in ovo method at the 28th hour of the incubation period. Group B was given distilled water; Group C, physiological saline; Group D, Levetiracetam (L8668) at a dose equivalent to the treatment dose for humans (10 mg/ kg), and Group E, Levetiracetam (L8668) at a dose of 10 times the treatment dose. The embryos in all of the groups were removed from the shells at the 48th hour and morphologically and histologically evaluated. Of the 45 embryos incubated, neural tubes of 41 were closed and the embryos displayed normal development. Levetiracetam, at a dose equivalent to human treatment dose and 10 times the treatment dose, was shown not to cause neural tube defects in chick embryos.
Baek, Jin Hyen; Hassell, Kathryn; Nuss, Rachelle; Eigenberger, Paul; Lisk, Christina; Loomis, Zoe; Maltzahn, Joanne; Stenmark, Kurt R; Nozik-Grayck, Eva
2015-01-01
Objective Haptoglobin (Hp) is an approved treatment in Japan with indications for trauma, burns and massive transfusion related hemolysis. Additional case reports suggest uses in other acute hemolytic events that lead to acute kidney injury. However, Hp's protective effects on the pulmonary vasculature have not been evaluated within the context of mitigating the consequences of chronic hemoglobin (Hb) exposure in the progression of pulmonary hypertension (PH) secondary to hemolytic diseases. This study was performed to assess the utility of chronic Hp therapy in a preclinical model of Hb and hypoxia mediated PH. Approach and results Rats were simultaneously exposed to chronic Hb-infusion (35 mg per day) and hypobaric hypoxia for five weeks in the presence or absence of Hp treatment (90 mg/kg twice a week). Hp inhibited the Hb plus hypoxia-mediated non-heme iron accumulation in lung and heart tissue, pulmonary vascular inflammation and resistance, and right ventricular hypertrophy, which suggest a positive impact on impeding the progression of PH. In addition, Hp therapy was associated with a reduction in critical mediators of PH, including lung adventitial macrophage population and endothelial ICAM-1 expression. Conclusions By preventing Hb-mediated pathology, Hp infusions: (1) demonstrate a critical role for Hb in vascular remodeling associated with hypoxia; and (2) suggest a novel therapy for chronic hemolysis associated PH. PMID:25656991
Irwin, David C; Baek, Jin Hyen; Hassell, Kathryn; Nuss, Rachelle; Eigenberger, Paul; Lisk, Christina; Loomis, Zoe; Maltzahn, Joanne; Stenmark, Kurt R; Nozik-Grayck, Eva; Buehler, Paul W
2015-05-01
Haptoglobin (Hp) is an approved treatment in Japan for trauma, burns, and massive transfusion-related hemolysis. Additional case reports suggest uses in other acute hemolytic events that lead to acute kidney injury. However, Hp's protective effects on the pulmonary vasculature have not been evaluated within the context of mitigating the consequences of chronic hemoglobin (Hb) exposure in the progression of pulmonary hypertension (PH) secondary to hemolytic diseases. This study was performed to assess the utility of chronic Hp therapy in a preclinical model of Hb and hypoxia-mediated PH. Rats were simultaneously exposed to chronic Hb infusion (35 mg per day) and hypobaric hypoxia for 5 weeks in the presence or absence of Hp treatment (90 mg/kg twice a week). Hp inhibited the Hb plus hypoxia-mediated nonheme iron accumulation in lung and heart tissue, pulmonary vascular inflammation and resistance, and right-ventricular hypertrophy, which suggests a positive impact on impeding the progression of PH. In addition, Hp therapy was associated with a reduction in critical mediators of PH, including lung adventitial macrophage population and endothelial ICAM-1 expression. By preventing Hb-mediated pathology, Hp infusions: (1) demonstrate a critical role for Hb in vascular remodeling associated with hypoxia and (2) suggest a novel therapy for chronic hemolysis-associated PH. Copyright © 2015 Elsevier Inc. All rights reserved.
Rodrigues, A; Nguyen, G; Li, Y; Roy Choudhury, K; Kirsch, D; Das, S; Yoshizumi, T
2012-06-01
To verify the accuracy of TG-61 based dosimetry with MOSFET technology using a tissue-equivalent mouse phantom. Accuracy of mouse dose between a TG-61 based look-up table was verified with MOSFET technology. The look-up table followed a TG-61 based commissioning and used a solid water block and radiochromic film. A tissue-equivalent mouse phantom (2 cm diameter, 8 cm length) was used for the MOSFET method. Detectors were placed in the phantom at the head and center of the body. MOSFETs were calibrated in air with an ion chamber and f-factor was applied to derive the dose to tissue. In CBCT mode, the phantom was positioned such that the system isocenter coincided with the center of the MOSFET with the active volume perpendicular to the beam. The absorbed dose was measured three times for seven different collimators, respectively. The exposure parameters were 225 kVp, 13 mA, and an exposure time of 20 s. For a 10 mm, 15 mm, and 20 mm circular collimator, the dose measured by the phantom was 4.3%, 2.7%, and 6% lower than TG-61 based measurements, respectively. For a 10 × 10 mm, 20 × 20 mm, and 40 × 40 mm collimator, the dose difference was 4.7%, 7.7%, and 2.9%, respectively. The MOSFET data was systematically lower than the commissioning data. The dose difference is due to the increased scatter radiation in the solid water block versus the dimension of the mouse phantom leading to an overestimation of the actual dose in the solid water block. The MOSFET method with the use of a tissue- equivalent mouse phantom provides less labor intensive geometry-specific dosimetry and accuracy with better dose tolerances of up to ± 2.7%. © 2012 American Association of Physicists in Medicine.
Franklin, Gregory; Conceição, Luis F R; Kombrink, Erich; Dias, Alberto C P
2009-01-01
Xanthone production in Hypericum perforatum (HP) suspension cultures in response to elicitation by Agrobacterium tumefaciens co-cultivation has been studied. RNA blot analyses of HP cells co-cultivated with A. tumefaciens have shown a rapid up-regulation of genes encoding important enzymes of the general phenylpropanoid pathway (PAL, phenylalanine ammonia lyase and 4CL, 4-coumarate:CoA ligase) and xanthone biosynthesis (BPS, benzophenone synthase). Analyses of HPLC chromatograms of methanolic extracts of control and elicited cells (HP cells that were co-cultivated for 24h with A. tumefaciens) have revealed a 12-fold increase in total xanthone concentration and also the emergence of many xanthones after elicitation. Methanolic extract of elicited cells exhibited significantly higher antioxidant and antimicrobial competence than the equivalent extract of control HP cells indicating that these properties have been significantly increased in HP cells after elicitation. Four major de novo synthesized xanthones have been identified as 1,3,6,7-tetrahydroxy-8-prenyl xanthone, 1,3,6,7-tetrahydroxy-2-prenyl xanthone, 1,3,7-trihydroxy-6-methoxy-8-prenyl xanthone and paxanthone. Antioxidant and antimicrobial characterization of these de novo xanthones have revealed that xanthones play dual function in plant cells during biotic stress: (1) as antioxidants to protect the cells from oxidative damage and (2) as phytoalexins to impair the pathogen growth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quevedo, A; Nicolucci, P
2014-06-01
Purpose: Analyse the water-equivalence of MAGIC-f polymer gel for {sup 60}Co and {sup 192}Ir clinical brachytherapy sources, through dose distributions simulated with PENELOPE Monte Carlo code. Methods: The real geometry of {sup 60} (BEBIG, modelo Co0.A86) and {sup 192}192Ir (Varian, model GammaMed Plus) clinical brachytherapy sources were modelled on PENELOPE Monte Carlo simulation code. The most probable emission lines of photons were used for both sources: 17 emission lines for {sup 192}Ir and 12 lines for {sup 60}. The dose distributions were obtained in a cubic water or gel homogeneous phantom (30 × 30 × 30 cm{sup 3}), with themore » source positioned in the middle of the phantom. In all cases the number of simulation showers remained constant at 10{sup 9} particles. A specific material for gel was constructed in PENELOPE using weight fraction components of MAGIC-f: wH = 0,1062, wC = 0,0751, wN = 0,0139, wO = 0,8021, wS = 2,58×10{sup −6} e wCu = 5,08 × 10{sup −6}. The voxel size in the dose distributions was 0.6 mm. Dose distribution maps on the longitudinal and radial direction through the centre of the source were used to analyse the water-equivalence of MAGIC-f. Results: For the {sup 60} source, the maximum diferences in relative doses obtained in the gel and water were 0,65% and 1,90%, for radial and longitudinal direction, respectively. For {sup 192}Ir, the maximum difereces in relative doses were 0,30% and 1,05%, for radial and longitudinal direction, respectively. The materials equivalence can also be verified through the effective atomic number and density of each material: Zef-MAGIC-f = 7,07 e .MAGIC-f = 1,060 g/cm{sup 3} and Zef-water = 7,22. Conclusion: The results showed that MAGIC-f is water equivalent, consequently being suitable to simulate soft tissue, for Cobalt and Iridium energies. Hence, gel can be used as a dosimeter in clinical applications. Further investigation to its use in a clinical protocol is needed.« less
Lim, Hyeon Woo; Kim, Tae Hyun; Choi, Il Ju; Kim, Chan Gyoo; Lee, Jong Yeul; Cho, Soo Jeong; Eom, Hyeon Seok; Moon, Sung Ho; Kim, Dae Yong
2016-01-01
Purpose To assess the clinical outcomes of radiotherapy (RT) using two-dimensional (2D) and three-dimensional conformal RT (3D-CRT) for patients with gastric mucosa-associated lymphoid tissue (MALT) lymphoma to evaluate the effectiveness of involved field RT with moderate-dose and to evaluate the benefit of 3D-CRT comparing with 2D-RT. Materials and Methods Between July 2003 and March 2015, 33 patients with stage IE and IIE gastric MALT lymphoma received RT were analyzed. Of 33 patients, 17 patients (51.5%) were Helicobacter pylori (HP) negative and 16 patients (48.5%) were HP positive but refractory to HP eradication (HPE). The 2D-RT (n = 14) and 3D-CRT (n = 19) were performed and total dose was 30.6 Gy/17 fractions. Of 11 patients who RT planning data were available, dose-volumetric parameters between 2D-RT and 3D-CRT plans was compared. Results All patients reached complete remission (CR) eventually and median time to CR was 3 months (range, 1 to 15 months). No local relapse occurred and one patient died with second primary malignancy. Tumor response, survival, and toxicity were not significantly different between 2D-RT and 3D-CRT (p > 0.05, each). In analysis for dose-volumetric parameters, Dmax and CI for PTV were significantly lower in 3D-CRT plans than 2D-RT plans (p < 0.05, each) and Dmean and V15 for right kidney and Dmean for left kidney were significantly lower in 3D-CRT than 2D-RT (p < 0.05, each). Conclusion Our data suggested that involved field RT with moderate-dose for gastric MALT lymphoma could be promising and 3D-CRT could be considered to improve the target coverage and reduce radiation dose to the both kidneys. PMID:27730803
A method for exposing rodents to resuspended particles using whole-body plethysmography
Wichers, Lindsay B; Ledbetter, Allen D; McGee, John K; Kellogg, Robert B; Rowan, William H; Nolan, Julianne P; Costa, Daniel L; Watkinson, William P
2006-01-01
Background Epidemiological studies have reported increased risks of cardiopulmonary-related hospitalization and death in association with exposure to elevated levels of particulate matter (PM) across a wide range of urban areas. In response to these findings, researchers have conducted animal inhalation exposures aimed at reproducing the observed toxicologic effects. However, it is technically difficult to quantitate the actual amount of PM delivered to the lung in such studies, and dose is frequently estimated using default respiration parameters. Consequently, the interpretation of PM-induced effects in rodents exposed via whole-body inhalation is often compromised by the inability to determine deposited dose. To address this problem, we have developed an exposure system that merges the generation of dry, aerosolized particles with whole-body plethysmography (WBP), thus permitting inhalation exposures in the unrestrained rat while simultaneously obtaining data on pulmonary function. Results This system was validated using an oil combustion-derived particle (HP12) at three nominal concentrations (3, 12, and 13 mg/m3) for four consecutive exposure days (6 hr/day); a single 6-hour exposure to 13 mg/m3 of HP12 was also conducted. These results demonstrated that the system was both reliable and consistent over these exposure protocols, achieving average concentrations that were within 10% of the targeted concentration. In-line filters located on the exhaust outlets of individual WBP chambers showed relative agreement in HP12 mass for each day and were not statistically different when compared to one another (p = 0.16). Temperatures and relative humidities were also similar between chambers during PM and air exposures. Finally, detailed composition analyses of both HP12 filter and bulk samples showed that grinding and aerosolization did not change particle chemistry. Conclusion The results of this study demonstrate that it is possible to expose rodents to resuspended, dry PM via whole-body inhalation while these animals are maintained in WBP chambers. This new methodology should significantly improve the ability to assess dosimetry under minimally stressful exposure conditions. PMID:16911796
Neutrons in active proton therapy: Parameterization of dose and dose equivalent.
Schneider, Uwe; Hälg, Roger A; Lomax, Tony
2017-06-01
One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160MeV or 177MeV instead of 138MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy. Copyright © 2016. Published by Elsevier GmbH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vitzthum, L; Ehler, E; Sterling, D
2015-06-15
Purpose: To evaluate a novel 3D printed bolus fabricated from a copper-plastic composite as a thin flexible, custom fitting device that can replicate doses achieved with conventional bolus techniques. Methods: Two models of bolus were created on a 3D printer using a composite copper-PLA/PHA. Firstly, boluses were constructed at thicknesses of 0.4, 0.6 and 0.8 mm. Relative dose measurements were performed under the bolus with an Attix Chamber as well as with radiochromic film. Results were compared to superficial Attix Chamber measurements in a water equivalent material to determine the dosimetric water equivalence of the copper-PLA/PHA plastic. Secondly, CT imagesmore » of a RANDO phantom were used to create a custom fitting bolus across the anterolateral scalp. Surface dose with the bolus placed on the RANDO phantom was measured with radiochromic film at tangential angles with 6, 10, 10 flattening filter free (FFF) and 18 MV photon beams. Results: Mean surface doses for 6, 10, 10FFF and 18 MV were measured as a percent of Dmax for the flat bolus devices of each thickness. The 0.4 mm thickness bolus was determined to be near equivalent to 2.5 mm depth in water for all four energies. Surface doses ranged from 59–63% without bolus and 85–90% with the custom 0.4 mm copper-plastic bolus relative to the prescribed dose for an oblique tangential beam arrangement on the RANDO phantom. Conclusion: Sub-millimeter thickness, 3D printed composite copper-PLA/PHA bolus can provide a build-up effect equivalent to conventional bolus. At this thickness, the 3D printed bolus allows a level of flexure that may provide more patient comfort than current 3D printing materials used in bolus fabrication while still retaining the CT based custom patient shape. Funding provided by an intra-department grant of the University of Minnesota Department of Radiation Oncology.« less
Dose Calibration of the ISS-RAD Fast Neutron Detector
NASA Technical Reports Server (NTRS)
Zeitlin, C.
2015-01-01
The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of ?10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.
Comparative evaluation of power factor impovement techniques for squirrel cage induction motors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spee, R.; Wallace, A.K.
1992-04-01
This paper describes the results obtained from a series of tests of relatively simple methods of improving the power factor of squirrel-cage induction motors. The methods, which are evaluated under controlled laboratory conditions for a 10-hp, high-efficiency motor, include terminal voltage reduction; terminal static capacitors; and a floating'' winding with static capacitors. The test results are compared with equivalent circuit model predictions that are then used to identify optimum conditions for each of the power factor improvement techniques compared with the basic induction motor. Finally, the relative economic value, and the implications of component failures, of the three methods aremore » discussed.« less
Kumagai, S.; Koda, S.; Miyakita, T.; Yamaguchi, H.; Katagi, K.; Yasuda, N.
2000-01-01
OBJECTIVES—To find whether concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in serum increased in workers at municipal incinerators that burn continuously. METHODS—30 Workers employed at three municipal waste incineration plants (incinerator workers) and 30 control workers were studied. The incinerator workers had worn dust masks or airline masks during the periodic repair work inside the incinerators. Previous job, dietary habit, smoking habit, distance from residence to the incineration plant, and body weight and height were obtained from a questionnaire survey. Concentrations of PCDDs/PCDFs were measured in the serum of the workers and the dust deposited in the plants. The influence of various factors on serum concentrations of PCDDs/PCDFs was examined by multiple regression analysis. RESULTS—Dust analysis showed the greatest amount of octachlorodibenzo-p-dioxin (OCDD), followed by 1,2,3,4,6,7,8-heptachlorodibenzo-p-dioxin (HpCDD), 1,2,3,4,6,7,8-heptachlorodibenzofuran (HpCDF), and octachlorodibenzofuran (OCDF). The toxicity equivalents (TEQs) of PCDDs and PCDFs in the deposited dust were 4.8, 1.0, and 6.4 ng TEQs/g, respectively, for plants A, B, and C. The mean serum TEQs of PCDDs and PCDFs in the incinerator workers and control workers were 19.2 and 22.9 pg TEQs/g lipid, respectively, for area A, 28.8 and 24.5 pg TEQs/g lipid for area B, and 23.4 and 23.6 pg TEQs/g lipid for area C. No significant differences were found between the incinerator workers and the controls for TEQs of PCDDs and PCDFs separately, and TEQs of PCDDs and PCDFs together. However, the serum 1,2,3,4,6,7,8-HpCDF concentration was significantly higher in the incinerator workers than in the controls for all the three areas. When the exposure index to 1,2,3,4,6,7,8-HpCDF is defined as the product of the concentration of 1,2,3,4,6,7,8-HpCDF in the deposited dust and duration of employment, the concentration of 1,2,3,4,6,7,8-HpCDF in serum increased as the exposure index increased. Multivariate analysis suggested that the serum concentration of HpCDF increased with duration of employment at the incineration plants and OCDF increased with employment of ⩾21 years. The other significant variables (p<0.01 or p<0.001) were area for hexachlorodibenzo-p-dioxin (HxCDD) and tetrachlorodibenzofuran (TCDF), Brinkman index for HpCDD, and body mass index (BMI) for tetrachlorodibenzo-p-dioxin (TCDD), HpCDD, and TEQs of PCDDs. CONCLUSION—The serum TEQs of PCDDs and PCDFs was not significantly higher among the incinerator workers, but the serum concentration of 1,2,3,4,6,7,8-HpCDF was. This suggests that the incinerator workers had inhaled dust containing PCDDs and PCDFs while working in plants equipped with incinerators that burn continuously. Keywords: serum dioxins; municipal waste incinerators; continuous burning; heptachlorodibenzofuran PMID:10810104
Organ dose measurement using Optically Stimulated Luminescence Detector (OSLD) during CT examination
NASA Astrophysics Data System (ADS)
Yusuf, Muhammad; Alothmany, Nazeeh; Abdulrahman Kinsara, Abdulraheem
2017-10-01
This study provides detailed information regarding the imaging doses to patient radiosensitive organs from a kilovoltage computed tomography (CT) scan procedure using OSLD. The study reports discrepancies between the measured dose and the calculated dose from the ImPACT scan, as well as a comparison with the dose from a chest X-ray radiography procedure. OSLDs were inserted in several organs, including the brain, eyes, thyroid, lung, heart, spinal cord, breast, spleen, stomach, liver and ovaries, of the RANDO phantom. Standard clinical scanning protocols were used for each individual site, including the brain, thyroid, lung, breast, stomach, liver and ovaries. The measured absorbed doses were then compared with the simulated dose obtained from the ImPACT scan. Additionally, the equivalent doses for each organ were calculated and compared with the dose from a chest X-ray radiography procedure. Absorbed organ doses measured by OSLD in the RANDO phantom of up to 17 mGy depend on the organ scanned and the scanning protocols used. A maximum 9.82% difference was observed between the target organ dose measured by OSLD and the results from the ImPACT scan. The maximum equivalent organ dose measured during this experiment was equal to 99.899 times the equivalent dose from a chest X-ray radiography procedure. The discrepancies between the measured dose with the OSLD and the calculated dose from the ImPACT scan were within 10%. This report recommends the use of OSLD for measuring the absorbed organ dose during CT examination.
Tashiro, Yuto; Hasegawa, Satoshi; Yokota, Yuki; Nishiguchi, Shu; Fukutani, Naoto; Shirooka, Hidehiko; Tasaka, Seishiro; Matsushita, Tomofumi; Matsubara, Keisuke; Nakayama, Yasuaki; Sonoda, Takuya; Tsuboyama, Tadao; Aoyama, Tomoki
2017-09-01
This study aims to evaluate the effects of Capacitive and Resistive electric transfer (CRet) and hotpack (HP) on haemoglobin saturation and tissue temperature. The participants were 13 healthy males (mean age 24.5 ± 3.0). They underwent three interventions on different days: (1) CRet (CRet group), (2) HP (HP group) and (3) CRet without power (sham group). The intervention and measurement were applied at the lower paraspinal muscle. Indiba ® active ProRecovery HCR902 was used in the CRet group, and the moist heat method was used in the HP group. Oxygenated, deoxygenated and total haemoglobin (oxy-Hb, deoxy-Hb, total-Hb) counts were measured before and after the 15-min interventions, together with the temperature at the skin surface, and at depths of 10 mm and 20 mm (ST, 10mmDT and 20mmDT, respectively). The haemoglobin saturation and tissue temperature were measured until 30 min after the intervention and were collected at 5-min intervals. Statistical analysis was performed for each index by using the Mann-Whitney U test for comparisons between all groups at each time point. Total-Hb and oxy-Hb were significantly higher in the CRet group than in the HP group continuously for 30 min after the intervention. The 10mmDT and 20mmDT were significantly higher in the CRet group than in the HP group from 10- to 30 min after intervention. The effect on haemoglobin saturation was higher in the CRet group than in the HP group. In addition, the CRet intervention warmed deep tissue more effectively than HP intervention.
Reft, C
2012-06-01
Luminescent dosimetry using thermoluminescent detectors (TLDs) and optically stimulated luminescent detectors (OSLDs) were used in mixed radiation fields containing both low LET (photons and protons) and high LET (neutrons)components to obtain their out-of-field absorbed dose, dose equivalent and quality factor. LiF Thermoluminescent Detectors (TLDs) 600 and 700 chips with dimensions 0.31×0.31×0.038 cm 3 were used in a 25.4 cm diameter Bonner sphere centered 42 cm from the isocenter of a 15×x15 cm 2 field to measure the secondary doses for 10, 15 and 18 MV photons and a 200 MeV proton therapy beam. From the sensitivity difference to LET radiation between the210 and 280 C peaks in the glow curve, the areas under the peaks were used to obtain the absorbed dose, dose equivalent and QF of the secondary radiation. The OSLD detector measured the low LET dose component to compare with the TLD dose measurement. The neutron calibration of the TLDs was obtained from an Am-Be source at the Argonne National Laboratory. The photon and proton TLD and OSLD calibrations were obtained in 6 MV and 200 MeV beams, respectively. From the two-peak analysis of the TLDs in the Bonner sphere the ratios of the neutron dose to photon dose were 0.001, 0.014 and 0.17 for 10, 15 and 18 MV, respectively. The low LET OSLD measurements agreed within 10% of the TLD results. From the dose equivalent measurements the QFs (+/-14%) obtained were 4.5, 3.9 and 4.0 for these beam energies. For the 200 MeV proton beam the ratio of neutron to proton dose was 0.28 with a measured QF of 13. Luminescent detectors in a Bonner Sphere provide measurements of the secondary photon, proton and neutron doses and provide an estimate of the neutron QF. © 2012 American Association of Physicists in Medicine.
El-Jaby, Samy
2016-06-01
A recent paper published in Life Sciences in Space Research (El-Jaby and Richardson, 2015) presented estimates of the secondary neutron ambient and effective dose equivalent rates, in air, from surface altitudes up to suborbital altitudes and low Earth orbit. These estimates were based on MCNPX (LANL, 2011) (Monte Carlo N-Particle eXtended) radiation transport simulations of galactic cosmic radiation passing through Earth's atmosphere. During a recent review of the input decks used for these simulations, a systematic error was discovered that is addressed here. After reassessment, the neutron ambient and effective dose equivalent rates estimated are found to be 10 to 15% different, though, the essence of the conclusions drawn remains unchanged. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Inaba, Kazunori; Murata, Kazuya; Naruto, Shunsuke; Matsuda, Hideaki
2010-04-01
Successive oral administration (50 mg/kg) of a 50% ethanolic extract (HP-ext) of devil's claw, the secondary root of Harpagophytum procumbens, showed a significant anti-inflammatory effect in the rat adjuvant-induced chronic arthritis model. HP-ext dose-dependently suppressed the lipopolysaccharide (LPS)-induced production of inflammatory cytokines [interleukin-1beta (IL-1beta), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha)] in mouse macrophage cells (RAW 264.7). Harpagoside, a major iridoid glycoside present in devil's claw, was found to be one of the active agents in HP-ext and inhibited the production of IL-1beta, IL-6, and TNF-alpha by RAW 264.7.
Daures, J; Gouriou, J; Bordy, J M
2011-03-01
This work has been performed within the frame of the European Union ORAMED project (Optimisation of RAdiation protection for MEDical staff). The main goal of the project is to improve standards of protection for medical staff for procedures resulting in potentially high exposures and to develop methodologies for better assessing and for reducing, exposures to medical staff. The Work Package WP2 is involved in the development of practical eye-lens dosimetry in interventional radiology. This study is complementary of the part of the ENEA report concerning the calculations with the MCNP-4C code of the conversion factors related to the operational quantity H(p)(3). In this study, a set of energy- and angular-dependent conversion coefficients (H(p)(3)/K(a)), in the newly proposed square cylindrical phantom made of ICRU tissue, have been calculated with the Monte-Carlo code PENELOPE and MCNP5. The H(p)(3) values have been determined in terms of absorbed dose, according to the definition of this quantity, and also with the kerma approximation as formerly reported in ICRU reports. At a low-photon energy (up to 1 MeV), the two results obtained with the two methods are consistent. Nevertheless, large differences are showed at a higher energy. This is mainly due to the lack of electronic equilibrium, especially for small angle incidences. The values of the conversion coefficients obtained with the MCNP-4C code published by ENEA quite agree with the kerma approximation calculations obtained with PENELOPE. We also performed the same calculations with the code MCNP5 with two types of tallies: F6 for kerma approximation and *F8 for estimating the absorbed dose that is, as known, due to secondary electrons. PENELOPE and MCNP5 results agree for the kerma approximation and for the absorbed dose calculation of H(p)(3) and prove that, for photon energies larger than 1 MeV, the transport of the secondary electrons has to be taken into account.
Considerations for applying VARSKIN mod 2 to skin dose calculations averaged over 10 cm2.
Durham, James S
2004-02-01
VARSKIN Mod 2 is a DOS-based computer program that calculates the dose to skin from beta and gamma contamination either directly on skin or on material in contact with skin. The default area for calculating the dose is 1 cm2. Recently, the U.S. Nuclear Regulatory Commission issued new guidelines for calculating shallow dose equivalent from skin contamination that requires the dose be averaged over 10 cm2. VARSKIN Mod 2 was not filly designed to calculate beta or gamma dose estimates averaged over 10 cm2, even though the program allows the user to calculate doses averaged over 10 cm2. This article explains why VARSKIN Mod 2 overestimates the beta dose when applied to 10 cm2 areas, describes a manual method for correcting the overestimate, and explains how to perform reasonable gamma dose calculations averaged over 10 cm2. The article also describes upgrades underway in Varskin 3.
Personal Dose Equivalent Conversion Coefficients For Photons To 1 GEV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veinot, K. G.; Hertel, N. E.
2010-09-27
The personal dose equivalent, H{sub p}(d), is the quantity recommended by the International Commission on Radiation Units and Measurements (ICRU) to be used as an approximation of the protection quantity Effective Dose when performing personal dosemeter calibrations. The personal dose equivalent can be defined for any location and depth within the body. Typically, the location of interest is the trunk where personal dosemeters are usually worn and in this instance a suitable approximation is a 30 cm X 30 cm X 15 cm slab-type phantom. For this condition the personal dose equivalent is denoted as H{sub p,slab}(d) and the depths,more » d, are taken to be 0.007 cm for non-penetrating and 1 cm for penetrating radiation. In operational radiation protection a third depth, 0.3 cm, is used to approximate the dose to the lens of the eye. A number of conversion coefficients for photons are available for incident energies up to several MeV, however, data to higher energies are limited. In this work conversion coefficients up to 1 GeV have been calculated for H{sub p,slab}(10) and H{sub p,slab}(3) using both the kerma approximation and by tracking secondary charged particles. For H{sub p}(0.07) the conversion coefficients were calculated, but only to 10 MeV due to computational limitations. Additionally, conversions from air kerma to H{sub p,slab}(d) have been determined and are reported. The conversion coefficients were determined for discrete incident energies, but analytical fits of the coefficients over the energy range are provided. Since the inclusion of air can influence the production of secondary charged particles incident on the face of the phantom conversion coefficients have been determined both in vacuo and with the source and slab immersed within a sphere in air. The conversion coefficients for the personal dose equivalent are compared to the appropriate protection quantity, calculated according to the recommendations of the latest International Commission on Radiological Protection (ICRP) guidance.« less
Code of Federal Regulations, 2012 CFR
2012-01-01
... to the Act. Administrative controls means the provisions relating to organization and management... agreement under subsection 274b. of the Act. Non-Agreement State means any other State. Alert means events... equivalent means the sum of the products of the dose equivalent to the body organ or tissue and the weighting...
Code of Federal Regulations, 2013 CFR
2013-01-01
... to the Act. Administrative controls means the provisions relating to organization and management... agreement under subsection 274b. of the Act. Non-Agreement State means any other State. Alert means events... equivalent means the sum of the products of the dose equivalent to the body organ or tissue and the weighting...
Code of Federal Regulations, 2011 CFR
2011-01-01
... to the Act. Administrative controls means the provisions relating to organization and management... agreement under subsection 274b. of the Act. Non-Agreement State means any other State. Alert means events... equivalent means the sum of the products of the dose equivalent to the body organ or tissue and the weighting...
Code of Federal Regulations, 2010 CFR
2010-01-01
... to the Act. Administrative controls means the provisions relating to organization and management... agreement under subsection 274b. of the Act. Non-Agreement State means any other State. Alert means events... equivalent means the sum of the products of the dose equivalent to the body organ or tissue and the weighting...
Code of Federal Regulations, 2014 CFR
2014-01-01
... to the Act. Administrative controls means the provisions relating to organization and management... agreement under subsection 274b. of the Act. Non-Agreement State means any other State. Alert means events... equivalent means the sum of the products of the dose equivalent to the body organ or tissue and the weighting...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Commission has entered into an effective agreement under subsection 274b. of the Act. Non-agreement State... access control measures that are not related to the safe use of, or security of, radiological materials... equivalent means the sum of the products of the dose equivalent to the organ or tissue and the weighting...
Alejo, L; Koren, C; Corredoira, E; Sánchez, F; Bayón, J; Serrada, A; Guibelalde, E
2017-04-01
To analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose. The eye lens dose was estimated in terms of H p (0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The H p (0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (P KA ) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions. The annual eye lens doses estimated on goggles were 4.13±0.93 and 4.98±1.28mSv. Over the aprons, the doses obtained were 10.83±0.99 and 11.97±1.44mSv. The correlation between the goggles and the apron dose was R 2 =0.89, with a ratio of 0.38. The correlation with the patient dose was R 2 =0.40, with a ratio of 1.79μSvGy -1 cm -2 . The dose per procedure obtained over the aprons was 102±16μSv, and on goggles 40±9μSv. The eye lens dose normalized to P KA was 2.21±0.58μSvGy -1 cm -2 . Measurements of personal dose equivalent over the paediatric cardiologist's apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Mechanisms of molecular transport through the urea channel of Helicobacter pylori
McNulty, Reginald; Ulmschneider, Jakob P.; Luecke, Hartmut; Ulmschneider, Martin B.
2013-01-01
Helicobacter pylori survival in acidic environments relies on cytoplasmic hydrolysis of gastric urea into ammonia and carbon dioxide, which buffer the pathogen’s periplasm. Urea uptake is greatly enhanced and regulated by HpUreI, a proton-gated inner membrane channel protein essential for gastric survival of H. pylori. The crystal structure of HpUreI describes a static snapshot of the channel with two constriction sites near the center of the bilayer that are too narrow to allow passage of urea or even water. Here we describe the urea transport mechanism at atomic resolution, revealed by unrestrained microsecond equilibrium molecular dynamics simulations of the hexameric channel assembly. Two consecutive constrictions open to allow conduction of urea, which is guided through the channel by interplay between conserved residues that determine proton rejection and solute selectivity. Remarkably, HpUreI conducts water at rates equivalent to aquaporins, which might be essential for efficient transport of urea at small concentration gradients. PMID:24305683
Mechanisms of molecular transport through the urea channel of Helicobacter pylori
NASA Astrophysics Data System (ADS)
McNulty, Reginald; Ulmschneider, Jakob P.; Luecke, Hartmut; Ulmschneider, Martin B.
2013-12-01
Helicobacter pylori survival in acidic environments relies on cytoplasmic hydrolysis of gastric urea into ammonia and carbon dioxide, which buffer the pathogen’s periplasm. Urea uptake is greatly enhanced and regulated by HpUreI, a proton-gated inner membrane channel protein essential for gastric survival of H. pylori. The crystal structure of HpUreI describes a static snapshot of the channel with two constriction sites near the center of the bilayer that are too narrow to allow passage of urea or even water. Here we describe the urea transport mechanism at atomic resolution, revealed by unrestrained microsecond equilibrium molecular dynamics simulations of the hexameric channel assembly. Two consecutive constrictions open to allow conduction of urea, which is guided through the channel by interplay between conserved residues that determine proton rejection and solute selectivity. Remarkably, HpUreI conducts water at rates equivalent to aquaporins, which might be essential for efficient transport of urea at small concentration gradients.
NASA Astrophysics Data System (ADS)
Jiang, Yan-Ke; Zou, Jian-Wei; Wu, Yu-Qian; Zhang, Na; Yu, Qing-Sen; Jiang, Yong-Jun
Trimethylation of histone H3 lysine 9 is important for recruiting heterochromatin protein 1 (HP1) to discrete regions of the genome, thereby regulating gene expression, chromatin packaging, and heterochromatin formation. Phosphorylation of histone H3 has been linked with mitotic chromatin condensation. During mitosis in vivo, H3 lysine 9 methylation and serine 10 phosphorylation can occur concomitantly on the same histone tail, whereas the influence of phosphorylation to trimethylation H3 tail recruiting HP1 remains controversial. In this work, molecular dynamics simulation of HP1 complexed with both trimethylated and phosphorylated H3 tail were performed and compared with the results from the previous methylated H3-HP1 trajectory. It is clear from the 10-ns dynamics simulation that two adjacent posttranslational modifications directly increase the flexibility of the H3 tail and weaken HP1 binding to chromatin. A combinatorial readout of two adjacent posttranslational modifications-a stable methylation and a dynamic phosphorylation mark-establish a regulatory mechanism of protein-protein interactions.
Carinou, Eleutheria; Stamatelatos, Ion Evangelos; Kamenopoulou, Vassiliki; Georgolopoulou, Paraskevi; Sandilos, Panayotis
The development of a computational model for the treatment head of a medical electron accelerator (Elekta/Philips SL-18) by the Monte Carlo code mcnp-4C2 is discussed. The model includes the major components of the accelerator head and a pmma phantom representing the patient body. Calculations were performed for a 14 MeV electron beam impinging on the accelerator target and a 10 cmx10 cm beam area at the isocentre. The model was used in order to predict the neutron ambient dose equivalent at the isocentre level and moreover the neutron absorbed dose distribution within the phantom. Calculations were validated against experimental measurements performed by gold foil activation detectors. The results of this study indicated that the equivalent dose at tissues or organs adjacent to the treatment field due to photoneutrons could be up to 10% of the total peripheral dose, for the specific accelerator characteristics examined. Therefore, photoneutrons should be taken into account when accurate dose calculations are required to sensitive tissues that are adjacent to the therapeutic X-ray beam. The method described can be extended to other accelerators and collimation configurations as well, upon specification of treatment head component dimensions, composition and nominal accelerating potential.
Boubred, Farid; Jamin, Agnes; Buffat, Christophe; Daniel, Laurent; Borel, Patrick; Boudry, Gaëlle; Le Huëron-Luron, Isabelle; Simeoni, Umberto
2017-05-01
In humans, early high protein (HP) intake has been recommended to prevent postnatal growth restriction and complications of intrauterine growth restriction (IUGR). However, the impact of such a strategy on the kidneys remains unknown, while significant renal hypertrophy, proteinuria, and glomerular sclerosis have been demonstrated in few experimental studies. The objective of this study was to evaluate the effects of a neonatal HP formula on renal structure in IUGR piglets. Spontaneous IUGR piglets were randomly allocated to normal protein (NP, n = 10) formula or to HP formula (+50% protein content, n = 10) up to day 28 after birth. Body weight, body composition, renal functions, and structure were assessed at the end of the neonatal period. While birth weights were similar, 28-day-old HP piglets were 18% heavier than NP piglets ( P < 0.01). Carcass protein content was 22% higher in HP than in NP offspring ( P < 0.01). Despite a HP intake, kidney weight and glomerular fibrosis were unaltered in HP piglets. Only a 20% increase in glomerular volume was noted in HP piglets ( P < 0.05) and restricted to the inner cortical area nephrons ( P = 0.03). Plasma urea/creatinine ratio and proteinuria were unchanged in HP piglets. In conclusion, neonatal HP feeding in IUGR piglets significantly enhanced neonatal growth and tissue protein deposition but mildly affected glomerular volume. It can be speculated that a sustained tissue protein anabolism in response to HP intake have limited single nephron glomerular hyperfiltration. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Pantin-Jackwood, Mary J.; Stephens, Christopher B.; Bertran, Kateri; Swayne, David E.
2017-01-01
In January 2016, a combined outbreak of highly pathogenic (HP) avian influenza virus (AIV) and low pathogenicity (LP) AIV occurred in commercial turkeys in the state of Indiana, United States. Genetically, the viruses were highly similar, belonged to the North American wild bird lineage, and had not been previously detected in poultry. In order to understand the pathobiology of the H7N8 LPAIV and HPAIV, infectivity, transmission and pathogenicity studies were conducted in chickens, turkeys, and mallards. Among the three species the lowest mean infectious dose for both the LP and HP phenotype was for turkeys, and also disease from the LPAIV was only observed with turkeys. Furthermore, although the HPAIV was lethal for both chickens and turkeys, clinical signs caused by the HPAIV isolate differed between the two species; neurological signs were only observed in turkeys. Mallards could be infected with and transmit both viruses to contacts, but neither caused clinical disease. Interestingly, with all three species, the mean infectious dose of the HP isolate was at least ten times lower than that of the LP isolate. This study corroborates the high susceptibility of turkeys to AIV as well as a pathobiology that is different from chickens. Further, this study demonstrates that mallards can be asymptomatically infected with HP and LP AIV from gallinaceous poultry and may not just be involved in transmitting AIV to them. PMID:28481948
Hypericum perforatum L. treatment restored bone mass changes in swimming stressed rats.
Seferos, Nikos; Petrokokkinos, Loukas; Kotsiou, Antonia; Rallis, George; Tesseromatis, Christine
2016-01-01
Stress, via corticosteroids release, influences bone mass density. Hypericum perforatum (Hp) a traditional remedy possess antidepressive activity (serotonin reuptake inhibitor) and wound healing properties. Hp preparation contains mainly hypericin, hyperforin, hyperoside and flavonoids exerting oestrogen-mimetic effect. Cold swimming represents an experimental model of stress associating mental strain and corporal exhaustion. This study investigates the Hp effect on femur and mandible bone mass changes in rats under cold forced swimming procedure. 30 male Wistar rats were randomized into three groups. Group A was treated with Methanolic extract of Hp (Jarsin®) via gastroesophageal catheter, and was submitted to cold swimming stress for 10 min/daily. Group B was submitted to cold stress, since group C served as control. Experiment duration was 10 days. Haematocrite and serum free fatty acids (FFA) were estimated. Furthermore volume and specific weight of each bone as well as bone mass density via dual energy X-Ray absorptiometry (DEXA) were measured. Statistic analysis by t-test. Hp treatment restores the stress injuries. Adrenals and bone mass density regain their normal values. Injuries occurring by forced swimming stress in the rats are significantly improved by Hp treatment. Estrogen-like effects of Hp flavonoids eventually may act favorable in bone remodeling.
Can the Equivalent Sphere Model Approximate Organ Doses in Space Radiation Environments?
NASA Technical Reports Server (NTRS)
Zi-Wei, Lin
2007-01-01
In space radiation calculations it is often useful to calculate the dose or dose equivalent in blood-forming organs (BFO). the skin or the eye. It has been customary to use a 5cm equivalent sphere to approximate the BFO dose. However previous studies have shown that a 5cm sphere gives conservative dose values for BFO. In this study we use a deterministic radiation transport with the Computerized Anatomical Man model to investigate whether the equivalent sphere model can approximate organ doses in space radiation environments. We find that for galactic cosmic rays environments the equivalent sphere model with an organ-specific constant radius parameter works well for the BFO dose equivalent and marginally well for the BFO dose and the dose equivalent of the eye or the skin. For solar particle events the radius parameters for the organ dose equivalent increase with the shielding thickness, and the model works marginally for BFO but is unacceptable for the eye or the skin The ranges of the radius parameters are also shown and the BFO radius parameters are found to be significantly larger than 5 cm in all eases.
Preliminary analysis of accelerated space flight ionizing radiation testing
NASA Technical Reports Server (NTRS)
Wilson, J. W.; Stock, L. V.; Carter, D. J.; Chang, C. K.
1982-01-01
A preliminary analysis shows that radiation dose equivalent to 30 years in the geosynchronous environment can be accumulated in a typical composite material exposed to space for 2 years or less onboard a spacecraft orbiting from perigee of 300 km out to the peak of the inner electron belt (approximately 2750 km). Future work to determine spacecraft orbits better tailored to materials accelerated testing is indicated. It is predicted that a range of 10 to the 9th power to 10 to the 10th power rads would be accumulated in 3-6 mil thick epoxy/graphite exposed by a test spacecraft orbiting in the inner electron belt. This dose is equivalent to the accumulated dose that this material would be expected to have after 30 years in a geosynchronous orbit. It is anticipated that material specimens would be brought back to Earth after 2 years in the radiation environment so that space radiation effects on materials could be analyzed by laboratory methods.
SU-E-T-756: Tissue Inhomogeneity Corrections in Intra-Operative Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sethi, A; Chinsky, B; Gros, S
Purpose: Investigate the impact of tissue inhomogeneities on dose distributions produced by low-energy X-rays in intra-operative radiotherapy (IORT). Methods: A 50-kV INTRABEAM X-ray device with superficial (Flat and Surface) applicators was commissioned at our institution. For each applicator, percent depth-dose (PDD), dose-profiles (DP) and output factors (OF) were obtained. Calibrated GaFchromic (EBT3) films were used to measure dose distributions in solid water phantom at various depths (2, 5, 10, and 15 mm). All recommended precautions for film-handling, film-exposure and scanning were observed. The effects of tissue inhomogeneities on dose distributions were examined by placing air-cavities and bone and tissue equivalentmore » materials of different density (ρ), atomic number (Z), and thickness (t = 0–4mm) between applicator and film detector. All inhomogeneities were modeled as a cylindrical cavity (diameter 25 mm). Treatment times were calculated to deliver 1Gy dose at 5mm depth. Film results were verified by repeat measurements with a thin-window parallel plate ion-chamber (PTW 34013A) in a water tank. Results: For a Flat-4cm applicator, the measured dose rate at 5mm depth in solid water was 0.35 Gy/min. Introduction of a cylindrical air-cavity resulted in an increased dose past the inhomogeneity. Compared to tissue equivalent medium, dose enhancement due to 1mm, 2mm, 3mm and 4mm air cavities was 10%, 16%, 24%, and 35% respectively. X-ray attenuation by 2mm thick cortical bone resulted in a significantly large (58%) dose decrease. Conclusion: IORT dose calculations assume homogeneous tissue equivalent medium. However, soft X-rays are easily affected by non-tissue equivalent materials. The results of this study may be used to estimate and correct IORT dose delivered in the presence of tissue inhomogeneities.« less
Veiner, Hilla-Lee; Gorbatov, Rostic; Vardi, Moshe; Doros, Gheorghe; Miller-Lotan, Rachel; Zohar, Yaniv; Sabo, Edmond; Asleh, Rabea; Levy, Nina S; Goldfarb, Levi J; Berk, Thomas A; Haas, Tali; Shalom, Hadar; Suss-Toby, Edith; Kam, Adi; Kaplan, Marielle; Tamir, Ronit; Ziskind, Anna; Levy, Andrew P
2015-03-01
Homozygosity for a 1.7 kb intragenic duplication of the Haptoglobin (Hp) gene (Hp 2-2 genotype), present in 36% of the population, has been associated with a 2-3 fold increased incidence of atherothrombosis in individuals with Diabetes (DM) in 10 longitudinal studies compared to DM individuals not homozygous for this duplication (Hp 1-1/2-1). The increased CVD risk associated with the Hp 2-2 genotype has been shown to be prevented with vitamin E supplementation in man. We sought to determine if there was an interaction between the Hp genotype and vitamin E on atherosclerotic plaque growth and stability in a transgenic model of the Hp polymorphism. Brachiocephalic artery atherosclerotic plaque volume was serially assessed by high resolution ultrasound in 28 Hp 1-1 and 26 Hp 2-2 mice in a C57Bl/6 ApoE(-/-) background. Hp 2-2 mice had more rapid plaque growth and an increased incidence of plaque hemorrhage and rupture. Vitamin E significantly reduced plaque growth in Hp 2-2 but not in Hp 1-1 mice with a significant pharmacogenomic interaction between the Hp genotype and vitamin E on plaque growth. These results may help explain why vitamin E supplementation in man can prevent CVD in Hp 2-2 DM but not in non Hp 2-2 DM individuals. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
The effects of piracetam on heroin-induced CPP and neuronal apoptosis in rats.
Xu, Peng; Li, Min; Bai, Yanping; Lu, Wei; Ling, Xiaomei; Li, Weidong
2015-05-01
Piracetam is a positive allosteric modulator of the AMPA receptor that has been used in the treatment of cognitive disorders for decades. Recent surveys and drug analyses have demonstrated that a heroin mixture adulterated with piracetam has spread rapidly in heroin addicts in China, but its addictive properties and the damage it causes to the central neural system are currently unknown. The effect of piracetam on the reward properties of heroin was assessed by conditioned place preference (CPP). Electron microscopy and radioimmunoassay were used to compare the effects of heroin mixed with equivalent piracetam (HP) and heroin alone on neuronal apoptosis and the levels of beta-endorphin (β-EP) in different brain subregions within the corticolimbic system, respectively. Piracetam significantly enhanced heroin-induced CPP expression while piracetam itself didn't induce CPP. Morphological observations showed that HP-treated rats had less neuronal apoptosis than heroin-treated group. Interestingly, HP normalized the levels of β-EP in the medial prefrontal cortex (mPFC) and core of the nucleus accumbens (AcbC) subregions, in where heroin-treated rats showed decreased levels of β-EP. These results indicate that piracetam potentiate the heroin-induced CPP and protect neurons from heroin-induced apoptosis. The protective role of HP might be related to the restoration of β-EP levels by piracetam. Our findings may provide a potential interpretation for the growing trend of HP abuse in addicts in China. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Reducing peanut allergens by high pressure combined with polyphenol oxidase
NASA Astrophysics Data System (ADS)
Chung, Si-Yin; Houska, Milan; Reed, Shawndrika
2013-12-01
Polyphenol oxidase (PPO) has been shown to reduce major peanut allergens. Since high pressure (HP) can increase enzyme activity, we postulated that further reduction of peanut allergens can be achieved through HP combined with PPO. Peanut extracts containing caffeic acid were treated with each of the following: (1) HP; (2) HP+PPO; (3) PPO; and (4) none. HP was conducted at 300 and 500 MPa, each for 3 and 10 min, 37 °C. After treatment, SDS-PAGE was performed and allergenic capacity (IgE binding) was determined colorimetrically in inhibition enzyme-linked immunosorbent assay and Western blots, using a pooled plasma from peanut-allergic patients. Data showed that HP alone had no effect on major peanut allergens. However, HP at 500 MPa combined with PPO (HP500/PPO) induced a higher (approximately twofold) reduction of major peanut allergens and IgE binding than PPO alone or HP300/PPO. There was no difference between treatment times. We concluded that HP500/PPO at 3-min enhanced a twofold reduction of the allergenic capacity of peanut extracts, as compared to PPO itself.
Olsher, Richard H.; Hsu, Hsiao-Hua; Casson, William H.; Vasilik, Dennis G.; Kleck, Jeffrey H.; Beverding, Anthony
1996-01-01
A neutron dose equivalent detector for measuring neutron dose capable of accurately responding to neutron energies according to published fluence to dose curves. The neutron dose equivalent meter has an inner sphere of polyethylene, with a middle shell overlying the inner sphere, the middle shell comprising RTV.RTM. silicone (organosiloxane) loaded with boron. An outer shell overlies the middle shell and comprises polyethylene loaded with tungsten. The neutron dose equivalent meter defines a channel through the outer shell, the middle shell, and the inner sphere for accepting a neutron counter tube. The outer shell is loaded with tungsten to provide neutron generation, increasing the neutron dose equivalent meter's response sensitivity above 8 MeV.
Haptoglobin gene subtypes in three Brazilian population groups of different ethnicities
2009-01-01
Haptoglobin is a plasma hemoglobin-binding protein that limits iron loss during normal erythrocyte turnover and hemolysis, thereby preventing oxidative damage mediated by iron excess in the circulation. Haptoglobin polymorphism in humans, characterized by the Hp*1 and Hp *2 alleles, results in distinct phenotypes known as Hp1-1, Hp2-1 and Hp2-2, whose frequencies vary according to the ethnic origin of the population. The Hp*1 allele has two subtypes, Hp *1F and Hp *1S , that also vary in their frequencies among populations worldwide. In this work, we examined the distribution frequencies of haptoglobin subtypes in three Brazilian population groups of different ethnicities. The haptoglobin genotypes of Kayabi Amerindians (n = 56), Kalunga Afro-descendants (n = 70) and an urban population (n = 132) were determined by allele-specific PCR. The Hp*1F allele frequency was highest in Kalunga (29.3%) and lowest in Kayabi (2.6%). The Hp*1F/Hp*1S allele frequency ratios were 0.6, 1.0 and 0.26 for the Kayabi, Kalunga and urban populations, respectively. This variation was attributable largely to the Hp*1F allele. However, despite the large variation in Hp*1F frequencies, results of F ST (0.0291) indicated slight genetic differentiation among subpopulations of the general Brazilian population studied here. This is the first Brazilian report of variations in the Hp*1F and Hp*1S frequencies among non-Amerindian Brazilians. PMID:21637505
Haptoglobin gene subtypes in three Brazilian population groups of different ethnicities.
Miranda-Vilela, Ana L; Akimoto, Arthur K; Alves, Penha C Z; Hiragi, Cássia O; Penalva, Guilherme C; Oliveira, Silviene F; Grisolia, Cesar K; Klautau-Guimarães, Maria N
2009-07-01
Haptoglobin is a plasma hemoglobin-binding protein that limits iron loss during normal erythrocyte turnover and hemolysis, thereby preventing oxidative damage mediated by iron excess in the circulation. Haptoglobin polymorphism in humans, characterized by the Hp(*1) and Hp (*2) alleles, results in distinct phenotypes known as Hp1-1, Hp2-1 and Hp2-2, whose frequencies vary according to the ethnic origin of the population. The Hp(*1) allele has two subtypes, Hp (*1F) and Hp (*1S) , that also vary in their frequencies among populations worldwide. In this work, we examined the distribution frequencies of haptoglobin subtypes in three Brazilian population groups of different ethnicities. The haptoglobin genotypes of Kayabi Amerindians (n = 56), Kalunga Afro-descendants (n = 70) and an urban population (n = 132) were determined by allele-specific PCR. The Hp(*1F) allele frequency was highest in Kalunga (29.3%) and lowest in Kayabi (2.6%). The Hp(*1F)/Hp(*1S) allele frequency ratios were 0.6, 1.0 and 0.26 for the Kayabi, Kalunga and urban populations, respectively. This variation was attributable largely to the Hp(*1F) allele. However, despite the large variation in Hp(*1F) frequencies, results of F (ST) (0.0291) indicated slight genetic differentiation among subpopulations of the general Brazilian population studied here. This is the first Brazilian report of variations in the Hp(*1F) and Hp(*1S) frequencies among non-Amerindian Brazilians.
Estimates of internal-dose equivalent from inhalation and ingestion of selected radionuclides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunning, D.E.
1982-01-01
This report presents internal radiation dose conversion factors for radionuclides of interest in environmental assessments of nuclear fuel cycles. This volume provides an updated summary of estimates of committed dose equivalent for radionuclides considered in three previous Oak Ridge National Laboratory (ORNL) reports. Intakes by inhalation and ingestion are considered. The International Commission on Radiological Protection (ICRP) Task Group Lung Model has been used to simulate the deposition and retention of particulate matter in the respiratory tract. Results corresponding to activity median aerodynamic diameters (AMAD) of 0.3, 1.0, and 5.0 ..mu..m are given. The gastorintestinal (GI) tract has been representedmore » by a four-segment catenary model with exponential transfer of radioactivity from one segment to the next. Retention of radionuclides in systemic organs is characterized by linear combinations of decaying exponential functions, recommended in ICRP Publication 30. The first-year annual dose rate, maximum annual dose rate, and fifty-year dose commitment per microcurie intake of each radionuclide is given for selected target organs and the effective dose equivalent. These estimates include contributions from specified source organs plus the systemic activity residing in the rest of the body; cross irradiation due to penetrating radiations has been incorporated into these estimates. 15 references.« less
Bliven-Sizemore, E E; Sterling, T R; Shang, N; Benator, D; Schwartzman, K; Reves, R; Drobeniuc, J; Bock, N; Villarino, M E
2015-09-01
Nine months of daily isoniazid (9H) and 3 months of once-weekly rifapentine plus isoniazid (3HP) are recommended treatments for latent tuberculous infection (LTBI). The risk profile for 3HP and the contribution of hepatitis C virus (HCV) infection to hepatotoxicity are unclear. To evaluate the hepatotoxicity risk associated with 3HP compared to 9H, and factors associated with hepatotoxicity. Hepatotoxicity was defined as aspartate aminotransferase (AST) >3 times the upper limit of normal (ULN) with symptoms (nausea, vomiting, jaundice, or fatigue), or AST >5 x ULN. We analyzed risk factors among adults who took at least 1 dose of their assigned treatment. A nested case-control study assessed the role of HCV. Of 6862 participants, 77 (1.1%) developed hepatotoxicity; 52 (0.8%) were symptomatic; 1.8% (61/3317) were on 9H and 0.4% (15/3545) were on 3HP (P < 0.0001). Risk factors for hepatotoxicity were age, female sex, white race, non-Hispanic ethnicity, decreased body mass index, elevated baseline AST, and 9H. In the case-control study, HCV infection was associated with hepatotoxicity when controlling for other factors. The risk of hepatotoxicity during LTBI treatment with 3HP was lower than the risk with 9H. HCV and elevated baseline AST were risk factors for hepatotoxicity. For persons with these risk factors, 3HP may be preferred.
High phosphate feeding promotes mineral and bone abnormalities in mice with chronic kidney disease.
Lau, Wei Ling; Linnes, Michael; Chu, Emily Y; Foster, Brian L; Bartley, Bryan A; Somerman, Martha J; Giachelli, Cecilia M
2013-01-01
Chronic kidney disease-mineral bone disorder (CKD-MBD) is a systemic syndrome characterized by imbalances in mineral homeostasis, renal osteodystrophy (ROD) and ectopic calcification. The mechanisms underlying this syndrome in individuals with chronic kidney disease (CKD) are not yet clear. We examined the effect of normal phosphate (NP) or high phosphate (HP) feeding in the setting of CKD on bone pathology, serum biochemistry and vascular calcification in calcification-prone dilute brown non-agouti (DBA/2) mice. In both NP and HP-fed CKD mice, elevated serum parathyroid hormone and alkaline phosphatase (ALP) levels were observed, but serum phosphorus levels were equivalent compared with sham controls. CKD mice on NP diet showed trabecular alterations in the long bone consistent with high-turnover ROD, including increased trabecular number with abundant osteoblasts and osteoclasts. Despite trabecular bone and serum biochemical changes, CKD/NP mice did not develop vascular calcification. In contrast, CKD/HP mice developed arterial medial calcification (AMC), more severe trabecular bone alterations and cortical bone abnormalities that included decreased cortical thickness and density, and increased cortical porosity. Cortical bone porosity and trabecular number strongly correlated with the degree of aortic calcification. HP feeding was required to induce the full spectrum of CKD-MBD symptoms in CKD mice.
New Stochastic Annual Limits on Intake for Selected Radionuclides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.
Annual limits on intake (ALI) have historically been tabulated by the International Commission on Radiological Protection (e.g., ICRP 1979, 1961) and also by the Environmental Protection Agency (EPA 1988). These compilations have been rendered obsolete by more recent ICRP dosimetry methods, and, rather than provide new ALIs, the ICRP has opted instead to provide committed dose coefficients from which an ALI can be determined by a user for a specific set of conditions. The U.S. Department of Energy historically has referenced compilations of ALIs and has defined their method of calculation in its radiation protection regulation (10 CFDR 835), butmore » has never provided a specific compilation. Under June 2007 amendments to 10 CFR 835, ALIs can be calculated by dividing an appropriate dose limit, either 5-rem (0.05 Sv) effective dose or 50 rem (0.5 Sv) equivalent dose to an individual organ or tissue, by an appropriate committed dose coefficient. When based on effective dose, the ALI is often referred to as a stochastic annual limit on intake (SALI), and when based on the individual organ or tissue equivalent limit, it has often been called a deterministic annual limit on intake (DALI).« less
Liao, Shang-Chih; Hung, Cheng-Chieh; Lee, Chien-Te; Lee, Chih-Hsiung; Lee, Chin-Chan; Lin, Chun-Liang; Sun, Chiao-Yin; Cheng, Ben-Chung; Yang, Chih-Chao; Wu, Chien-Hsing; Chen, Jin-Bor
2016-08-01
This multicenter study was designed to assess the hemoglobin (Hb) stability and conversion ratio of the switch from epoetin beta to darbepoetin alfa in Taiwanese hemodialysis (HD) patients. A total of 135 HD patients were enrolled and randomized with intravenous darbepoetin alfa or epoetin beta. The study duration was 24 weeks. Equivalent doses and conversion ratios were assessed with respect to Hb stratification: low Hb (≥8.0 g/dL to ≤10.0 g/dL) and high Hb (>10.0 g/dL to ≤11.0 g/dL). The results showed stable Hb levels in the study period. At week 24, the conversion ratio was higher for high Hb than low Hb (296.4 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa. vs. 277.2 IU/dose epoetin beta: 1 µg/dose darbepoetin alfa). In conclusion, the conversion ratio in the present study was higher than 1 µg: 200 IU for darbepoetin alfa: epoetin for treating anemia in Taiwanese HD patients. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.
Radon and leukemia in the Danish study: another source of dose.
Harley, Naomi H; Robbins, Edith S
2009-10-01
An epidemiologic study of childhood leukemia in Denmark (2,400 cases; 6,697 controls) from 1968 to 1994 suggested a weak, but statistically significant, association of residential radon exposure and acute childhood lymphoblastic leukemia (ALL). The Danish study estimated a relative risk (RR) = 1.56 (95% CI, 1.05-2.30) for a cumulative exposure of 1,000 Bq m-3 y. For an exposure duration of 10 y their RR corresponds to a radon concentration of 100 Bq m-3. There are two dose pathways of interest where alpha particles could damage potential stem cells for ALL. One is the alpha dose to bone marrow, and two is the dose to bronchial mucosa where an abundance of circulating lymphocytes is found. Compared with an exposure of about 1 mSv y-1 from natural external background, radon and decay products contribute an additional 10 to 60% to the bone marrow equivalent dose. The other pathway for exposure of T (or B) lymphocytes is within the tracheobronchial epithelium (BE). Inhaled radon decay products deposit on the relatively small area of airway surfaces and deliver a significant dose to the nearby basal or mucous cells implicated in human lung cancer. Lymphocytes are co-located with basal cells and are half as abundant. Using a 10-y exposure to 100 Bq m-3, our dose estimates suggest that the equivalent dose to these lymphocytes could approach 1 Sv. The relatively high dose estimate to lymphocytes circulating through the BE, potential precursor cells for ALL, provides a dose pathway for an association.
30 CFR Appendix II to Subpart D of... - Appendix II to Subpart D of Part 18
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Approval 2G- Motor: (Manufacturing Company) Frame ___ Hp., ___ Volts, ___ Ph., ___ Cy., ___ R.P.M. X/P... wires shall not be used for grounding except in conjunction with diode(s) or equivalent. The operating voltage should match the voltage rating of the motor(s). 2. Servicing. Explosion-proof enclosures shall be...
30 CFR Appendix II to Subpart D of... - Appendix II to Subpart D of Part 18
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Approval 2G- Motor: (Manufacturing Company) Frame ___ Hp., ___ Volts, ___ Ph., ___ Cy., ___ R.P.M. X/P... wires shall not be used for grounding except in conjunction with diode(s) or equivalent. The operating voltage should match the voltage rating of the motor(s). 2. Servicing. Explosion-proof enclosures shall be...
30 CFR Appendix II to Subpart D of... - Appendix II to Subpart D of Part 18
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Approval 2G- Motor: (Manufacturing Company) Frame ___ Hp., ___ Volts, ___ Ph., ___ Cy., ___ R.P.M. X/P... wires shall not be used for grounding except in conjunction with diode(s) or equivalent. The operating voltage should match the voltage rating of the motor(s). 2. Servicing. Explosion-proof enclosures shall be...
30 CFR Appendix II to Subpart D of... - Appendix II to Subpart D of Part 18
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Approval 2G- Motor: (Manufacturing Company) Frame ___ Hp., ___ Volts, ___ Ph., ___ Cy., ___ R.P.M. X/P... wires shall not be used for grounding except in conjunction with diode(s) or equivalent. The operating voltage should match the voltage rating of the motor(s). 2. Servicing. Explosion-proof enclosures shall be...
30 CFR Appendix II to Subpart D of... - Appendix II to Subpart D of Part 18
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Approval 2G- Motor: (Manufacturing Company) Frame ___ Hp., ___ Volts, ___ Ph., ___ Cy., ___ R.P.M. X/P... wires shall not be used for grounding except in conjunction with diode(s) or equivalent. The operating voltage should match the voltage rating of the motor(s). 2. Servicing. Explosion-proof enclosures shall be...
42 CFR 81.4 - Definition of terms used in this part.
Code of Federal Regulations, 2011 CFR
2011-10-01
...]. (e) Equivalent dose means the absorbed dose in a tissue or organ multiplied by a radiation weighting... dose means the portion of the equivalent dose that is received from radiation sources outside of the... pattern and level of radiation exposure. (h) Internal dose means the portion of the equivalent dose that...
Zhang, Zhong-Lin; Liu, Zhi-Su; Sun, Quan
2005-01-01
AIM: To investigate the effects of thalidomide on angiogenesis, tumor growth and metastasis of hepatocellular carcinoma in nude mice. METHODS: Twenty-four nude mice were randomly divided into therapy group and control group, 12 mice in each group. Thalidomide dissolved in 0.5% sodium carboxyl methyl cellulose (CMC) suspension was administered intraperitoneally once a day at the dose of 200 mg/kg in therapy group, and an equivalent volume of 0.5% CMC in control group. Mice were sacrificed on the 30th d, tumor size and weight and metastases in liver and lungs were measured. CD34 and VEGF mRNA in tumor tissue were detected by immunohistochemistry and semi-quantitative RT-PCR respectively and microvessel density (MVD) was counted. Serum concentrations of TNF-α and ALT and AFP were also tested. RESULTS: MVD and VEGF mRNA in therapy group were less than those in control group (31.08±16.23 vessels/HP vs 80.00±26.27 vessels/HP, 0.0538±0.0165 vs 0.7373±0.1297, respectively, P<0.05). No statistical difference was observed in tumor size and weight and metastases in liver and lungs. TNF-α was significantly lower in therapy group than in control group (28.64±4.64 ng/L vs 42.69±6.99 ng/L, P<0.05). No statistical difference in ALT and AFP was observed between groups. CONCLUSION: Thalidomide can significantly inhibit angiogenesis and metastasis of hepatocellular carcinoma. It also has inhibitory effects on circulating TNF-α. PMID:15633219
Dowdy, John C; Czako, Eugene A; Stepp, Michael E; Schlitt, Steven C; Bender, Gregory R; Khan, Lateef U; Shinneman, Kenneth D; Karos, Manuel G; Shepherd, James G; Sayre, Robert M
2011-09-01
The authors compared calculations of sunlamp maximum exposure times following current USFDA Guidance Policy on the Maximum Timer Interval and Exposure Schedule, with USFDA/CDRH proposals revising these to equivalent erythemal exposures of ISO/CIE Standard Erythema Dose (SED). In 2003, [USFDA/CDRH proposed replacing their unique CDRH/Lytle] erythema action spectrum with the ISO/CIE erythema action spectrum and revising the sunlamp maximum exposure timer to 600 J m(-2) ISO/CIE effective dose, presented as being biologically equivalent. Preliminary analysis failed to confirm said equivalence, indicating instead ∼38% increased exposure when applying these proposed revisions. To confirm and refine this finding, a collaboration of tanning bed and UV lamp manufacturers compiled 89 UV spectra representing a broad sampling of U.S. indoor tanning equipment. USFDA maximum recommended exposure time (Te) per current sunlamp guidance and CIE erythemal effectiveness per ISO/CIE standard were calculated. The CIE effective dose delivered per Te averaged 456 J(CIE) m(-2) (SD = 0.17) or ∼4.5 SED. The authors found that CDRH's proposed 600 J(CIE) m(-2) recommended maximum sunlamp exposure exceeds current Te erythemal dose by ∼33%. The current USFDA 0.75 MED initial exposure was ∼0.9 SED, consistent with 1.0 SED initial dose in existing international sunlamp standards. As no sunlamps analyzed exceeded 5 SED, a revised maximum exposure of 500 J(CIE) m(-2) (∼80% of CDRH's proposal) should be compatible with existing tanning equipment. A tanning acclimatization schedule is proposed beginning at 1 SED thrice-weekly, increasing uniformly stepwise over 4 wk to a 5 SED maximum exposure in conjunction with a tan maintenance schedule of twice-weekly 5 SED sessions, as biologically equivalent to current USFDA sunlamp policy.
Andreasen, Nancy C; Pressler, Marcus; Nopoulos, Peg; Miller, Del; Ho, Beng-Choon
2010-02-01
A standardized quantitative method for comparing dosages of different drugs is a useful tool for designing clinical trials and for examining the effects of long-term medication side effects such as tardive dyskinesia. Such a method requires establishing dose equivalents. An expert consensus group has published charts of equivalent doses for various antipsychotic medications for first- and second-generation medications. These charts were used in this study. Regression was used to compare each drug in the experts' charts to chlorpromazine and haloperidol and to create formulas for each relationship. The formulas were solved for chlorpromazine 100 mg and haloperidol 2 mg to derive new chlorpromazine and haloperidol equivalents. The formulas were incorporated into our definition of dose-years such that 100 mg/day of chlorpromazine equivalent or 2 mg/day of haloperidol equivalent taken for 1 year is equal to one dose-year. All comparisons to chlorpromazine and haloperidol were highly linear with R(2) values greater than .9. A power transformation further improved linearity. By deriving a unique formula that converts doses to chlorpromazine or haloperidol equivalents, we can compare otherwise dissimilar drugs. These equivalents can be multiplied by the time an individual has been on a given dose to derive a cumulative value measured in dose-years in the form of (chlorpromazine equivalent in mg) x (time on dose measured in years). After each dose has been converted to dose-years, the results can be summed to provide a cumulative quantitative measure of lifetime exposure. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Eley, John; Newhauser, Wayne; Homann, Kenneth; Howell, Rebecca; Schneider, Christopher; Durante, Marco; Bert, Christoph
2015-01-01
Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects. PMID:25768061
Eley, John; Newhauser, Wayne; Homann, Kenneth; Howell, Rebecca; Schneider, Christopher; Durante, Marco; Bert, Christoph
2015-03-11
Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Stationary Non-Emergency SI Engines â¥100 HP (Except Gasoline and Rich Burn LPG), Stationary SI Landfill... Standards for Stationary Non-Emergency SI Engines ≥100 HP (Except Gasoline and Rich Burn LPG), Stationary SI...-Emergency SI Natural Gas b and Non-Emergency SI Lean Burn LPG b 100≤HP<500 7/1/2008 2.0 4.0 1.0 160 540 86 1...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Stationary Non-Emergency SI Engines â¥100 HP (Except Gasoline and Rich Burn LPG), Stationary SI Landfill... Standards for Stationary Non-Emergency SI Engines ≥100 HP (Except Gasoline and Rich Burn LPG), Stationary SI...-Emergency SI Natural Gas b and Non-Emergency SI Lean Burn LPG b 100≤HP<500 7/1/2008 2.0 4.0 1.0 160 540 86 1...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Stationary Non-Emergency SI Engines â¥100 HP (Except Gasoline and Rich Burn LPG), Stationary SI Landfill... Standards for Stationary Non-Emergency SI Engines ≥100 HP (Except Gasoline and Rich Burn LPG), Stationary SI...-Emergency SI Natural Gas b and Non-Emergency SI Lean Burn LPG b 100≤HP<500 7/1/2008 2.0 4.0 1.0 160 540 86 1...
1990-08-01
reference signal 25 5 A METHOD FOR MEASURING LOW-PRF PULSED SIGNALS 28 5.1 Using a NWA with a smaller BPF 28 5.2 Using the HP 8510B external trigger...2nd LO 11Q 3MHz BPF lOkHz BPF Fig. 4: Receiver block diagram The receiver is a double conversion superheterodyne with a 10 kHz wide BandPass Filter... BPF ) in the second IF. This 10 kHz filter is the component that dictates how the HP 8510B responds to pulsed signals. For the pulsed-RF test signal
Threshold flux-controlled memristor model and its equivalent circuit implementation
NASA Astrophysics Data System (ADS)
Wu, Hua-Gan; Bao, Bo-Cheng; Chen, Mo
2014-11-01
Modeling a memristor is an effective way to explore the memristor properties due to the fact that the memristor devices are still not commercially available for common researchers. In this paper, a physical memristive device is assumed to exist whose ionic drift direction is perpendicular to the direction of the applied voltage, upon which, corresponding to the HP charge-controlled memristor model, a novel threshold flux-controlled memristor model with a window function is proposed. The fingerprints of the proposed model are analyzed. Especially, a practical equivalent circuit of the proposed model is realized, from which the corresponding experimental fingerprints are captured. The equivalent circuit of the threshold memristor model is appropriate for various memristors based breadboard experiments.
Razo-Aguilera, G; Baez-Reyes, R; Alvarez-González, I; Paniagua-Pérez, R; Madrigal-Bujaidar, E
2011-11-01
By means of the comet assay we demonstrated a strong effect by hydrogen peroxide (HP) and no damage by grapefruit juice (GJ) in human lymphocytes. Cells exposed to HP and treated with three concentrations of GJ (10-90 min) showed an increase of DNA damage by HP over the control level, and a decrease of such damage by GJ. With the comet assay plus formamidopyrimidine-DNA-glycosylase we found the strongest increase of DNA damage by HP over the control level, and the strongest reduction of such damage by GJ. By applying the comet/FISH method we determined 98% of the p53 gene signals in the comet head of control cells along the experiment (10-90 min), in contrast with about 90% signals in the comet tail of cells exposed to HP. Cells treated with both agents showed a significant, concentration/time dependent return of p53 signals to the head, suggesting enhancement of the gene repair. Finally, with the annexin V assay we found an increase in apoptosis and necrosis by HP, and no effect by GJ; when GJ was added to HP treated cells no modification was observed in regard to apoptosis, although a decrease of necrosis was observed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Derivation of mean dose tolerances for new fractionation schemes and treatment modalities
NASA Astrophysics Data System (ADS)
Perkó, Zoltán; Bortfeld, Thomas; Hong, Theodore; Wolfgang, John; Unkelbach, Jan
2018-02-01
Avoiding toxicities in radiotherapy requires the knowledge of tolerable organ doses. For new, experimental fractionation schemes (e.g. hypofractionation) these are typically derived from traditional schedules using the biologically effective dose (BED) model. In this report we investigate the difficulties of establishing mean dose tolerances that arise since the mean BED depends on the entire spatial dose distribution, rather than on the dose level alone. A formula has been derived to establish mean physical dose constraints such that they are mean BED equivalent to a reference treatment scheme. This formula constitutes a modified BED equation where the influence of the spatial dose distribution is summarized in a single parameter, the dose shape factor. To quantify effects we analyzed 24 liver cancer patients for whom both proton and photon IMRT treatment plans were available. The results show that the standard BED equation—neglecting the spatial dose distribution—can overestimate mean dose tolerances for hypofractionated treatments by up to 20%. The shape difference between photon and proton dose distributions can cause 30-40% differences in mean physical dose for plans having identical mean BEDs. Converting hypofractionated, 5/15-fraction proton doses to mean BED equivalent photon doses in traditional 35-fraction regimens resulted in up to 10 Gy higher doses than applying the standard BED formula. The dose shape effect should be accounted for to avoid overestimation of mean dose tolerances, particularly when estimating constraints for hypofractionated regimens. Additionally, tolerances established for one treatment modality cannot necessarily be applied to other modalities with drastically different dose distributions, such as proton therapy. Last, protons may only allow marginal (5-10%) dose escalation if a fraction-size adjusted organ mean dose is constraining instead of a physical dose.
Dose Equivalents for Antipsychotic Drugs: The DDD Method.
Leucht, Stefan; Samara, Myrto; Heres, Stephan; Davis, John M
2016-07-01
Dose equivalents of antipsychotics are an important but difficult to define concept, because all methods have weaknesses and strongholds. We calculated dose equivalents based on defined daily doses (DDDs) presented by the World Health Organisation's Collaborative Center for Drug Statistics Methodology. Doses equivalent to 1mg olanzapine, 1mg risperidone, 1mg haloperidol, and 100mg chlorpromazine were presented and compared with the results of 3 other methods to define dose equivalence (the "minimum effective dose method," the "classical mean dose method," and an international consensus statement). We presented dose equivalents for 57 first-generation and second-generation antipsychotic drugs, available as oral, parenteral, or depot formulations. Overall, the identified equivalent doses were comparable with those of the other methods, but there were also outliers. The major strength of this method to define dose response is that DDDs are available for most drugs, including old antipsychotics, that they are based on a variety of sources, and that DDDs are an internationally accepted measure. The major limitations are that the information used to estimate DDDS is likely to differ between the drugs. Moreover, this information is not publicly available, so that it cannot be reviewed. The WHO stresses that DDDs are mainly a standardized measure of drug consumption, and their use as a measure of dose equivalence can therefore be misleading. We, therefore, recommend that if alternative, more "scientific" dose equivalence methods are available for a drug they should be preferred to DDDs. Moreover, our summary can be a useful resource for pharmacovigilance studies. © The Author 2016. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Siebers, Jeffrey V
2008-04-04
Monte Carlo (MC) is rarely used for IMRT plan optimization outside of research centres due to the extensive computational resources or long computation times required to complete the process. Time can be reduced by degrading the statistical precision of the MC dose calculation used within the optimization loop. However, this eventually introduces optimization convergence errors (OCEs). This study determines the statistical noise levels tolerated during MC-IMRT optimization under the condition that the optimized plan has OCEs <100 cGy (1.5% of the prescription dose) for MC-optimized IMRT treatment plans.Seven-field prostate IMRT treatment plans for 10 prostate patients are used in this study. Pre-optimization is performed for deliverable beams with a pencil-beam (PB) dose algorithm. Further deliverable-based optimization proceeds using: (1) MC-based optimization, where dose is recomputed with MC after each intensity update or (2) a once-corrected (OC) MC-hybrid optimization, where a MC dose computation defines beam-by-beam dose correction matrices that are used during a PB-based optimization. Optimizations are performed with nominal per beam MC statistical precisions of 2, 5, 8, 10, 15, and 20%. Following optimizer convergence, beams are re-computed with MC using 2% per beam nominal statistical precision and the 2 PTV and 10 OAR dose indices used in the optimization objective function are tallied. For both the MC-optimization and OC-optimization methods, statistical equivalence tests found that OCEs are less than 1.5% of the prescription dose for plans optimized with nominal statistical uncertainties of up to 10% per beam. The achieved statistical uncertainty in the patient for the 10% per beam simulations from the combination of the 7 beams is ~3% with respect to maximum dose for voxels with D>0.5D(max). The MC dose computation time for the OC-optimization is only 6.2 minutes on a single 3 Ghz processor with results clinically equivalent to high precision MC computations.
Stojanovska, Zdenka; Boev, Blazo; Zunic, Zora S; Ivanova, Kremena; Ristova, Mimoza; Tsenova, Martina; Ajka, Sorsa; Janevik, Emilija; Taleski, Vaso; Bossew, Peter
2016-05-01
Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.
Gamboa-Dominguez, Armando; Ubbelohde, Tom; Saqui-Salces, Milena; Romano-Mazzoti, Luis; Cervantes, Minerva; Domínguez-Fonseca, Claudia; de la Luz Estreber, Maria; Ruíz-Palacios, Guillermo M
2007-06-01
Our aim was to determine if salt and stress enhance Helicobacter pylori (Hp) lesions in Meriones unguiculatus. Two hundred seventy-eight pathogen-free gerbils were allocated to seven groups: Hp-Sydney strain (45), 8% higher-salt diet (38), stress (60% space reduction/water immersion; 36), Hp + salt (33), Hp + stress (34), N-methyl-N-nitro-N-nitrosoguanidine (34), and sham (58). Gerbils were sacrificed at 1 week (67), 12 weeks (73), 52 weeks (65), and 68 weeks (73). Sydney, Padova, and Lauren classifications were blindly used. Proliferation, p53, p21, and apoptosis were assessed. Follicular active gastritis (grade 2/3) was observed in 10% of Hp gerbils, 38% of Hp + salt gerbils, and 29% of Hp + stress gerbils at 52 weeks and 67%, 83%, and 43% at 68 weeks (P < 0.05). Heterotopic proliferative glands were identified in synergy groups from 52 weeks, with increases in their number and size by 68 weeks. Higher proliferative rates were observed in Hp+salt gerbils (P < 0.0001), and p21 overexpression in Hp+salt and Hp+stress gerbils (both P's < 0.0001), by 68 weeks, without p53 increases. We conclude that salt and stress synergize Hp damage and increase pseudo-invasive gland foci.
Epidemiology and Health-Related Quality of Life in Hypoparathyroidism in Norway
Løvås, Kristian; Debowska, Aleksandra; Eriksen, Erik F.; Evang, Johan A.; Fossum, Christian; Fougner, Kristian J.; Holte, Synnøve E.; Lima, Kari; Moe, Ragnar B.; Myhre, Anne Grethe; Kemp, E. Helen; Nedrebø, Bjørn G.; Svartberg, Johan; Husebye, Eystein S.
2016-01-01
Objective: The epidemiology of hypoparathyroidism (HP) is largely unknown. We aimed to determine prevalence, etiologies, health related quality of life (HRQOL) and treatment pattern of HP. Methods: Patients with HP and 22q11 deletion syndrome (DiGeorge syndrome) were identified in electronic hospital registries. All identified patients were invited to participate in a survey. Among patients who responded, HRQOL was determined by Short Form 36 and Hospital Anxiety and Depression scale. Autoantibodies were measured and candidate genes (CaSR, AIRE, GATA3, and 22q11-deletion) were sequenced for classification of etiology. Results: We identified 522 patients (511 alive) and estimated overall prevalence at 102 per million divided among postsurgical HP (64 per million), nonsurgical HP (30 per million), and pseudo-HP (8 per million). Nonsurgical HP comprised autosomal dominant hypocalcemia (21%), autoimmune polyendocrine syndrome type 1 (17%), DiGeorge/22q11 deletion syndrome (15%), idiopathic HP (44%), and others (4%). Among the 283 respondents (median age, 53 years [range, 9–89], 75% females), seven formerly classified as idiopathic were reclassified after genetic and immunological analyses, whereas 26 (37% of nonsurgical HP) remained idiopathic. Most were treated with vitamin D (94%) and calcium (70%), and 10 received PTH. HP patients scored significantly worse than the normative population on Short Form 36 and Hospital Anxiety and Depression scale; patients with postsurgical scored worse than those with nonsurgical HP and pseudo-HP, especially on physical health. Conclusions: We found higher prevalence of nonsurgical HP in Norway than reported elsewhere. Genetic testing and autoimmunity screening of idiopathic HP identified a specific cause in 21%. Further research is necessary to unravel the causes of idiopathic HP and to improve the reduced HRQOL reported by HP patients. PMID:27186861
Epidemiology and Health-Related Quality of Life in Hypoparathyroidism in Norway.
Astor, Marianne C; Løvås, Kristian; Debowska, Aleksandra; Eriksen, Erik F; Evang, Johan A; Fossum, Christian; Fougner, Kristian J; Holte, Synnøve E; Lima, Kari; Moe, Ragnar B; Myhre, Anne Grethe; Kemp, E Helen; Nedrebø, Bjørn G; Svartberg, Johan; Husebye, Eystein S
2016-08-01
The epidemiology of hypoparathyroidism (HP) is largely unknown. We aimed to determine prevalence, etiologies, health related quality of life (HRQOL) and treatment pattern of HP. Patients with HP and 22q11 deletion syndrome (DiGeorge syndrome) were identified in electronic hospital registries. All identified patients were invited to participate in a survey. Among patients who responded, HRQOL was determined by Short Form 36 and Hospital Anxiety and Depression scale. Autoantibodies were measured and candidate genes (CaSR, AIRE, GATA3, and 22q11-deletion) were sequenced for classification of etiology. We identified 522 patients (511 alive) and estimated overall prevalence at 102 per million divided among postsurgical HP (64 per million), nonsurgical HP (30 per million), and pseudo-HP (8 per million). Nonsurgical HP comprised autosomal dominant hypocalcemia (21%), autoimmune polyendocrine syndrome type 1 (17%), DiGeorge/22q11 deletion syndrome (15%), idiopathic HP (44%), and others (4%). Among the 283 respondents (median age, 53 years [range, 9-89], 75% females), seven formerly classified as idiopathic were reclassified after genetic and immunological analyses, whereas 26 (37% of nonsurgical HP) remained idiopathic. Most were treated with vitamin D (94%) and calcium (70%), and 10 received PTH. HP patients scored significantly worse than the normative population on Short Form 36 and Hospital Anxiety and Depression scale; patients with postsurgical scored worse than those with nonsurgical HP and pseudo-HP, especially on physical health. We found higher prevalence of nonsurgical HP in Norway than reported elsewhere. Genetic testing and autoimmunity screening of idiopathic HP identified a specific cause in 21%. Further research is necessary to unravel the causes of idiopathic HP and to improve the reduced HRQOL reported by HP patients.
Vial, Philip; Gustafsson, Helen; Oliver, Lyn; Baldock, Clive; Greer, Peter B
2009-12-07
The routine use of electronic portal imaging devices (EPIDs) as dosimeters for radiotherapy quality assurance is complicated by the non-water equivalence of the EPID's dose response. A commercial EPID modified to a direct-detection configuration was previously demonstrated to provide water-equivalent dose response with d(max) solid water build-up and 10 cm solid water backscatter. Clinical implementation of the direct EPID (dEPID) requires a design that maintains the water-equivalent dose response, can be incorporated onto existing EPID support arms and maintains sufficient image quality for clinical imaging. This study investigated the dEPID dose response with different configurations of build-up and backscatter using varying thickness of solid water and copper. Field size output factors and beam profiles measured with the dEPID were compared with ionization chamber measurements of dose in water for both 6 MV and 18 MV. The dEPID configured with d(max) solid water build-up and no backscatter (except for the support arm) was within 1.5% of dose in water data for both energies. The dEPID was maintained in this configuration for clinical dosimetry and image quality studies. Close agreement between the dEPID and treatment planning system was obtained for an IMRT field with 98.4% of pixels within the field meeting a gamma criterion of 3% and 3 mm. The reduced sensitivity of the dEPID resulted in a poorer image quality based on quantitative (contrast-to-noise ratio) and qualitative (anthropomorphic phantom) studies. However, clinically useful images were obtained with the dEPID using typical treatment field doses. The dEPID is a water-equivalent dosimeter that can be implemented with minimal modifications to the standard commercial EPID design. The proposed dEPID design greatly simplifies the verification of IMRT dose delivery.
Howell, Rebecca M; Burgett, E A
2014-09-01
Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire energy range being measured, i.e., thermal to 250 MeV. The authors used the neutron fluence spectrum to demonstrate experimentally the contribution of neutrons with different energies to the total dose equivalent and in particular the contribution of high-energy neutrons (≥20 MeV). These are valuable reference data that can be directly compared with Monte Carlo and experimental data in the literature.
Howell, Rebecca M.; Burgett, E. A.
2014-01-01
Purpose: Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. Methods: The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. Results: The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. Conclusions: The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire energy range being measured, i.e., thermal to 250 MeV. The authors used the neutron fluence spectrum to demonstrate experimentally the contribution of neutrons with different energies to the total dose equivalent and in particular the contribution of high-energy neutrons (≥20 MeV). These are valuable reference data that can be directly compared with Monte Carlo and experimental data in the literature. PMID:25186404
Effects of hydrostatic pressure on leporine meniscus cell-seeded PLLA scaffolds.
Gunja, Najmuddin J; Athanasiou, Kyriacos A
2010-03-01
Hydrostatic pressure (HP) is an important component of the loading environment of the knee joint. Studies with articular chondrocytes and TMJ disc fibrochondrocytes have identified certain benefits of HP for tissue engineering purposes. However, similar studies with meniscus cells are lacking. Thus, in this experiment, the effects of applying 10 MPa of HP at three different frequencies (0, 0.1, and 1 Hz) to leporine meniscus cell-seeded PLLA scaffolds were examined. HP was applied once every 3 days for 1 h for a period of 28 days. Constructs were analyzed for cellular, biochemical, and biomechanical properties. At t = 4 weeks, total collagen/scaffold was found to be significantly higher in the 10 MPa, 0 Hz group when compared with other groups. This despite the fact that the cell numbers/scaffold were found to be lower in all HP groups when compared with the culture control. Additionally, the total GAG/scaffold, instantaneous modulus, and relaxation modulus were significantly increased in the 10 MPa, 0 Hz group when compared with the culture control. In summary, this experiment provides evidence for the benefit of a 10 MPa, 0 Hz stimulus, on both biochemical and biomechanical aspects, for the purposes of meniscus tissue engineering using PLLA scaffolds. (c) 2009 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Doucet, R.; Olivares, M.; DeBlois, F.; Podgorsak, E. B.; Kawrakow, I.; Seuntjens, J.
2003-08-01
Calculations of dose distributions in heterogeneous phantoms in clinical electron beams, carried out using the fast voxel Monte Carlo (MC) system XVMC and the conventional MC code EGSnrc, were compared with measurements. Irradiations were performed using the 9 MeV and 15 MeV beams from a Varian Clinac-18 accelerator with a 10 × 10 cm2 applicator and an SSD of 100 cm. Depth doses were measured with thermoluminescent dosimetry techniques (TLD 700) in phantoms consisting of slabs of Solid WaterTM (SW) and bone and slabs of SW and lung tissue-equivalent materials. Lateral profiles in water were measured using an electron diode at different depths behind one and two immersed aluminium rods. The accelerator was modelled using the EGS4/BEAM system and optimized phase-space files were used as input to the EGSnrc and the XVMC calculations. Also, for the XVMC, an experiment-based beam model was used. All measurements were corrected by the EGSnrc-calculated stopping power ratios. Overall, there is excellent agreement between the corrected experimental and the two MC dose distributions. Small remaining discrepancies may be due to the non-equivalence between physical and simulated tissue-equivalent materials and to detector fluence perturbation effect correction factors that were calculated for the 9 MeV beam at selected depths in the heterogeneous phantoms.
Doucet, R; Olivares, M; DeBlois, F; Podgorsak, E B; Kawrakow, I; Seuntjens, J
2003-08-07
Calculations of dose distributions in heterogeneous phantoms in clinical electron beams, carried out using the fast voxel Monte Carlo (MC) system XVMC and the conventional MC code EGSnrc, were compared with measurements. Irradiations were performed using the 9 MeV and 15 MeV beams from a Varian Clinac-18 accelerator with a 10 x 10 cm2 applicator and an SSD of 100 cm. Depth doses were measured with thermoluminescent dosimetry techniques (TLD 700) in phantoms consisting of slabs of Solid Water (SW) and bone and slabs of SW and lung tissue-equivalent materials. Lateral profiles in water were measured using an electron diode at different depths behind one and two immersed aluminium rods. The accelerator was modelled using the EGS4/BEAM system and optimized phase-space files were used as input to the EGSnrc and the XVMC calculations. Also, for the XVMC, an experiment-based beam model was used. All measurements were corrected by the EGSnrc-calculated stopping power ratios. Overall, there is excellent agreement between the corrected experimental and the two MC dose distributions. Small remaining discrepancies may be due to the non-equivalence between physical and simulated tissue-equivalent materials and to detector fluence perturbation effect correction factors that were calculated for the 9 MeV beam at selected depths in the heterogeneous phantoms.
Iwamoto, Yosuke; Ronningen, R M; Niita, Koji
2010-04-01
It has been sometimes necessary for personnel to work in areas where low-energy heavy ions interact with targets or with beam transport equipment and thereby produce significant levels of radiation. Methods to predict doses and to assist shielding design are desirable. The Particle and Heavy Ion Transport code System (PHITS) has been typically used to predict radiation levels around high-energy (above 100 MeV amu(-1)) heavy ion accelerator facilities. However, predictions by PHITS of radiation levels around low-energy (around 10 MeV amu(-1)) heavy ion facilities to our knowledge have not yet been investigated. The influence of the "switching time" in PHITS calculations of low-energy heavy ion reactions, defined as the time when the JAERI Quantum Molecular Dynamics model (JQMD) calculation stops and the Generalized Evaporation Model (GEM) calculation begins, was studied using neutron energy spectra from 6.25 MeV amu(-1) and 10 MeV amu(-1) (12)C ions and 10 MeV amu(-1) (16)O ions incident on a copper target. Using a value of 100 fm c(-1) for the switching time, calculated neutron energy spectra obtained agree well with the experimental data. PHITS was then used with the switching time of 100 fm c(-1) to simulate an experimental study by Ohnesorge et al. by calculating neutron dose equivalent rates produced by 3 MeV amu(-1) to 16 MeV amu(-1) (12)C, (14)N, (16)O, and (20)Ne beams incident on iron, nickel and copper targets. The calculated neutron dose equivalent rates agree very well with the data and follow a general pattern which appears to be insensitive to the heavy ion species but is sensitive to the target material.
Tissue-equivalent TL sheet dosimetry system for X- and gamma-ray dose mapping.
Nariyama, N; Konnai, A; Ohnishi, S; Odano, N; Yamaji, A; Ozasa, N; Ishikawa, Y
2006-01-01
To measure dose distribution for X- and gamma rays simply and accurately, a tissue-equivalent thermoluminescent (TL) sheet-type dosemeter and reader system were developed. The TL sheet is composed of LiF:Mg,Cu,P and ETFE polymer, and the thickness is 0.2 mm. For the TL reading, a square heating plate, 20 cm on each side, was developed, and the temperature distribution was measured with an infrared thermal imaging camera. As a result, linearity within 2% and the homogeneity within 3% were confirmed. The TL signal emitted is detected using a CCD camera and displayed as a spatial dose distribution. Irradiation using synchrotron radiation between 10 and 100 keV and (60)Co gamma rays showed that the TL sheet dosimetry system was promising for radiation dose mapping for various purposes.
Breuillard, Charlotte; Darquy, Sylviane; Curis, Emmanuel; Neveux, Nathalie; Garnier, Jean-Pierre; Cynober, Luc; De Bandt, Jean-Pascal
2012-08-01
Obese and type 2 diabetic patients present metabolic disturbance-related alterations in nonspecific immunity, to which the decrease in their plasma arginine contributes. Although diabetes-specific formulas have been developed, they have never been tested in the context of an acute infectious situation as can be seen in intensive care unit patients. Our aim was to investigate the effects of a diabetes-specific diet enriched or not with arginine in a model of infectious stress in a diabetes and obesity situation. As a large intake of arginine may be deleterious, this amino acid was given in graded fashion. Randomized, controlled experimental study. University research laboratory. Zucker diabetic fatty rats. Gastrostomized Zucker diabetic fatty rats were submitted to intraperitoneal lipopolysaccharide administration and fed for 7 days with either a diabetes-specific enteral nutrition without (G group, n=7) or with graded arginine supply (1-5 g/kg/day) (GA group, n=7) or a standard enteral nutrition (HP group, n=10). Survival rate was better in G and GA groups than in the HP group. On day 7, plasma insulin to glucose ratio tended to be lower in the same G and GA groups. Macrophage tumor necrosis factor-α (G: 5.0±1.1 ng/2×10⁶ cells·hr⁻¹; GA: 3.7±0.8 ng/2×10⁶ cells·hr⁻¹; and HP: 1.7±0.6 ng/2×10⁶ cells·hr⁻¹; p<.05 G vs. HP) and nitric oxide (G: 4.5±1.1 ng/2×10⁶ cells·hr⁻¹; GA: 5.1±1.0 ng/2×10⁶ cells·hr⁻¹; and HP: 1.0±0.5 nmol/2×10⁶ cells·hr⁻¹; p<.05 G and GA vs. HP) productions were higher in the G and GA groups compared to the HP group. Macrophages from the G and GA groups exhibited increased arginine consumption. In diabetic obese and endotoxemic rats, a diabetes-specific formula leads to a lower mortality, a decreased insulin resistance, and an improvement in peritoneal macrophage function. Arginine supplementation has no additional effect. These data support the use of such disease-specific diets in critically ill diabetic and obese patients.
Zhu, Ru-Gang; Sun, Yan-Di; Li, Tuo-Ping; Chen, Gang; Peng, Xue; Duan, Wen-Bin; Zheng, Zheng-Zheng; Shi, Shu-Lei; Xu, Jing-Guo; Liu, Yan-Hua; Jin, Xiao-Yi
2015-08-05
This study aims to compare the effects of feeding haw pectin (HP), haw pectin hydrolyzates (HPH), and haw pectin pentasaccharide (HPPS) on the cholesterol metabolism of hypercholesterolemic hamsters induced by high-cholesterol diets. The animals were fed a standard diet (SD), high-cholesterol diet (HCD), or HCD plus HP, HPH, or HPPS at a dose of 300mg/kg body weight for 4weeks. Results showed that HPPS was more effective than HP and HPH in decreasing the body weight gain (by 38.2%), liver weight (by 16.4%), and plasma and hepatic total cholesterol (TC; by 23.6% and 27.3%, respectively) of hamsters. In addition, the bile acid levels in the feces were significantly higher by 39.8% and 132.8% in the HPH and HPPS groups than in the HCD group. Such changes were not noted in the HP group. However, the HP group had higher cholesterol excretion capacities than the HPH and HPPS groups by inhibiting cholesterol absorption in the diet, with a 21.7% increase in TC excretion and a 31.1% decrease in TC absorption. Thus, HPPS could be a promising anti-atherogenic dietary ingredient for the development of functional food to improve cholesterol metabolism. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Zhang, Rui-San; He, Zhen; Jin, Wei-Dong; Wang, Rui
2016-10-01
The cannabinoid system plays an important role in memory processes, many studies have indicated that cannabinoid receptor ligands have ability to modulate memory in rodents. A nonapeptide hemopressin (Hp) derived from rat brain, acts as a peptide antagonist or selective inverse peptide agonist of cannabinoid 1 (CB1) receptor. N-terminally extended forms of Hp isolated from mouse brain, (m)RVD-hemopressin(α) (RVD) and (m)VD-hemopressin(α) (VD) also bind CB1 receptor, however, as peptide agonists. Here, we investigated the roles of Hp, RVD, and VD on memory in mice using novel object recognition (NOR) and object location recognition (OLR) tasks. In normal young mice, intracerebroventricular (i.c.v.) infusion of Hp before training not only improved memory formation, but also prolonged memory retention in the tasks, these effects could be inhibited by RVD or VD at the same dose and intraperitoneal (i.p.) injection of a small molecule agonist of CB1 receptor WIN55, 212-2 15min before administration of Hp inhibited the memory-improving effect of Hp. In addition, under the same experimental conditions, i.c.v. RVD or VD displayed memory-impairing effects, which could be prevented by Hp (i.c.v.) or AM251 (i.p.), a small molecule antagonist of CB1 receptor. Infusion of amyloid-β (1-42) (Aβ1-42) 14days before training resulted in impairment of memory in mice which could be used as animal model of Alzheimer's disease (AD). In these mice, RVD or VD (i.c.v.) reversed the memory impairment induced by Aβ1-42, and the effects of RVD and VD could be suppressed by Hp (i.c.v.) or AM251 (2mg/kg, i.p.). Separate administration of Hp had no effect in Aβ1-42-treated mice. The above results suggested that Hp, RVD and VD, as CB1 receptor peptide ligands, may be potential drugs to treatment of the memory deficit-involving disease, just as AD. Copyright © 2016 Elsevier Inc. All rights reserved.
Comparison of Martian Radiation Environment with International Space Station
2003-03-13
This graphic shows the radiation dose equivalent as measured by Odyssey's Martian radiation environment experiment at Mars and by instruments aboard the International Space Station, for the 11-month period from April 2002 through February 2003. The accumulated total in Mars orbit is about two and a half times larger than that aboard the Space Station. Averaged over this time period, about 10 percent of the dose equivalent at Mars is due to solar particles, although a 30 percent contribution from solar particles was seen in July 2002, when the sun was particularly active. http://photojournal.jpl.nasa.gov/catalog/PIA04258
High-protein-low-carbohydrate diet: deleterious metabolic and cardiovascular effects depend on age.
Bedarida, Tatiana; Baron, Stephanie; Vessieres, Emilie; Vibert, Francoise; Ayer, Audrey; Marchiol-Fournigault, Carmen; Henrion, Daniel; Paul, Jean-Louis; Noble, Florence; Golmard, Jean-Louis; Beaudeux, Jean-Louis; Cottart, Charles-Henry; Nivet-Antoine, Valerie
2014-09-01
High-protein-low-carbohydrate (HP-LC) diets have become widespread. Yet their deleterious consequences, especially on glucose metabolism and arteries, have already been underlined. Our previous study (2) has already shown glucose intolerance with major arterial dysfunction in very old mice subjected to an HP-LC diet. The hypothesis of this work was that this diet had an age-dependent deleterious metabolic and cardiovascular outcome. Two groups of mice, young and adult (3 and 6 mo old), were subjected for 12 wk to a standard or to an HP-LC diet. Glucose and lipid metabolism was studied. The cardiovascular system was explored from the functional stage with Doppler-echography to the molecular stage (arterial reactivity, mRNA, immunohistochemistry). Young mice did not exhibit any significant metabolic modification, whereas adult mice presented marked glucose intolerance associated with an increase in resistin and triglyceride levels. These metabolic disturbances were responsible for cardiovascular damages only in adult mice, with decreased aortic distensibility and left ventricle dysfunction. These seemed to be the consequence of arterial dysfunctions. Mesenteric arteries were the worst affected with a major oxidative stress, whereas aorta function seemed to be maintained with an appreciable role of cyclooxygenase-2 to preserve endothelial function. This study highlights for the first time the age-dependent deleterious effects of an HP-LC diet on metabolism, with glucose intolerance and lipid disorders and vascular (especially microvessels) and cardiac functions. This work shows that HP-LC lead to equivalent cardiovascular alterations, as observed in very old age, and underlines the danger of such diet. Copyright © 2014 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Zacharatou Jarlskog, Christina; Lee, Choonik; Bolch, Wesley E.; Xu, X. George; Paganetti, Harald
2008-02-01
Proton beams used for radiotherapy will produce neutrons when interacting with matter. The purpose of this study was to quantify the equivalent dose to tissue due to secondary neutrons in pediatric and adult patients treated by proton therapy for brain lesions. Assessment of the equivalent dose to organs away from the target requires whole-body geometrical information. Furthermore, because the patient geometry depends on age at exposure, age-dependent representations are also needed. We implemented age-dependent phantoms into our proton Monte Carlo dose calculation environment. We considered eight typical radiation fields, two of which had been previously used to treat pediatric patients. The other six fields were additionally considered to allow a systematic study of equivalent doses as a function of field parameters. For all phantoms and all fields, we simulated organ-specific equivalent neutron doses and analyzed for each organ (1) the equivalent dose due to neutrons as a function of distance to the target; (2) the equivalent dose due to neutrons as a function of patient age; (3) the equivalent dose due to neutrons as a function of field parameters; and (4) the ratio of contributions to secondary dose from the treatment head versus the contribution from the patient's body tissues. This work reports organ-specific equivalent neutron doses for up to 48 organs in a patient. We demonstrate quantitatively how organ equivalent doses for adult and pediatric patients vary as a function of patient's age, organ and field parameters. Neutron doses increase with increasing range and modulation width but decrease with field size (as defined by the aperture). We analyzed the ratio of neutron dose contributions from the patient and from the treatment head, and found that neutron-equivalent doses fall off rapidly as a function of distance from the target, in agreement with experimental data. It appears that for the fields used in this study, the neutron dose lateral to the field is smaller than the reported scattered photon doses in a typical intensity-modulated photon treatment. Most importantly, our study shows that neutron doses to specific organs depend considerably on the patient's age and body stature. The younger the patient, the higher the dose deposited due to neutrons. Given the fact that the risk also increases with decreasing patient age, this factor needs to be taken into account when treating pediatric patients of very young ages and/or of small body size. The neutron dose from a course of proton therapy treatment (assuming 70 Gy in 30 fractions) could potentially (depending on patient's age, organ, treatment site and area of CT scan) be equivalent to up to ~30 CT scans.
Effect of various tooth-whitening products on enamel microhardness.
Grobler, S R; Majeed, A; Moola, M H
2009-11-01
The purpose of this in vitro study was to evaluate the effect of various tooth-whitening products containing carbamide peroxide (CP) or hydrogen peroxide (HP), on enamel microhardness. Enamel blocks were exposed to: Nite White ACP 10% CP (Group 2, n=10); Yotuel Patient 10% CP (Group 3, n=10); Opalescence PF 10% CP (Group 4, n=10); Opalescence PF 20% CP (Group 5, n=10); Opalescence Treswhite Supreme 10% HP (Group 6, n=10); Yotuel 10 Minutes 30% CP (Group 7, n=10); Opalescence Quick 45% CP (Group 8, n=10), Yotuel Special 35% HP (Group 9, n=10), Opalescence Boost 38% HP (Group 10, n=10) according to the instructions of the manufacturers. The control (Group 1, n=10) was enamel blocks kept in artificial saliva at 37 degrees C without any treatment. The microhardness values were obtained before exposure and after a 14-day treatment period. Specimens were kept in artificial saliva at 37 degrees C between treatments. Data were analysed using Kruskal-Wallis one-way ANOVA and Tukey-Kramer Multiple Comparison Test. Indent marks on the enamel blocks were also examined under the Scanning Electron Microscope. All whitening products decreased enamel microhardness except group 10 but only Groups 2, 3, 4, 5 and 7 showed significant decrease in enamel microhardness as compared to the control group (p < 0.05). Groups 2, 3 and 7 differed significantly from all the other groups (p < 0.05). The highest damage was recorded for Group 2 (Nite White ACP 10% CP), which differed significantly from Groups 3 and 7. SEM images also showed damage to enamel. All products tested in this study decreased enamel microhardness except Opalescence Boost 38% HP. The products containing carbamide peroxide were more damaging to enamel because of the longer application times. Nite White ACP 10% CP showed the highest reduction in enamel microhardness as compared to other products tested.
Triple ionization chamber method for clinical dose monitoring with a Be-covered Li BNCT field.
Nguyen, Thanh Tat; Kajimoto, Tsuyoshi; Tanaka, Kenichi; Nguyen, Chien Cong; Endo, Satoru
2016-11-01
Fast neutron, gamma-ray, and boron doses have different relative biological effectiveness (RBE). In boron neutron capture therapy (BNCT), the clinical dose is the total of these dose components multiplied by their RBE. Clinical dose monitoring is necessary for quality assurance of the irradiation profile; therefore, the fast neutron, gamma-ray, and boron doses should be separately monitored. To estimate these doses separately, and to monitor the boron dose without monitoring the thermal neutron fluence, the authors propose a triple ionization chamber method using graphite-walled carbon dioxide gas (C-CO 2 ), tissue-equivalent plastic-walled tissue-equivalent gas (TE-TE), and boron-loaded tissue-equivalent plastic-walled tissue-equivalent gas [TE(B)-TE] chambers. To use this method for dose monitoring for a neutron and gamma-ray field moderated by D 2 O from a Be-covered Li target (Be-covered Li BNCT field), the relative sensitivities of these ionization chambers are required. The relative sensitivities of the TE-TE, C-CO 2 , and TE(B)-TE chambers to fast neutron, gamma-ray, and boron doses are calculated with the particle and heavy-ion transport code system (PHITS). The relative sensitivity of the TE(B)-TE chamber is calculated with the same method as for the TE-TE and C-CO 2 chambers in the paired chamber method. In the Be-covered Li BNCT field, the relative sensitivities of the ionization chambers to fast neutron, gamma-ray, and boron doses are calculated from the kerma ratios, mass attenuation coefficient tissue-to-wall ratios, and W-values. The Be-covered Li BNCT field consists of neutrons and gamma-rays which are emitted from a Be-covered Li target, and this resultant field is simulated by using PHITS with the cross section library of ENDF-VII. The kerma ratios and mass attenuation coefficient tissue-to-wall ratios are determined from the energy spectra of neutrons and gamma-rays in the Be-covered Li BNCT field. The W-value is calculated from recoil charged particle spectra by the collision of neutrons and gamma-rays with the wall and gas materials of the ionization chambers in the gas cavities of TE-TE, C-CO 2 , and TE(B)-TE chambers ( 10 B concentrations of 10, 50, and 100 ppm in the TE-wall). The calculated relative sensitivity of the C-CO 2 chamber to the fast neutron dose in the Be-covered Li BNCT field is 0.029, and those of the TE-TE and TE(B)-TE chambers are both equal to 0.965. The relative sensitivities of the C-CO 2 , TE-TE, and TE(B)-TE chambers to the gamma-ray dose in the Be-covered Li BNCT field are all 1 within the 1% calculation uncertainty. The relative sensitivities of TE(B)-TE to boron dose with concentrations of 10, 50, and 100 ppm 10 B are calculated to be 0.865 times the ratio of the in-tumor to in-chamber wall boron concentration. The fast neutron, gamma-ray, and boron doses of a tumor in-air can be separately monitored by the triple ionization chamber method in the Be-covered Li BNCT field. The results show that these doses can be easily converted to the clinical dose with the depth correction factor in the body and the RBE.
Thierry-Chef, I; Pernicka, F; Marshall, M; Cardis, E; Andreo, P
2002-01-01
An international collaborative study of cancer risk among workers in the nuclear industry is tinder way to estimate direetly the cancer risk following protracted low-dose exposure to ionising radiation. An essential aspect of this study is the characterisation and quantification of errors in available dose estimates. One major source of errors is dosemeter response in workplace exposure conditions. Little information is available on energy and geometry response for most of the 124 different dosemeters used historically in participating facilities. Experiments were therefore set up to assess this. using 10 dosemeter types representative of those used over time. Results show that the largest errors were associated with the response of early dosemeters to low-energy photon radiation. Good response was found with modern dosemeters. even at low energy. These results are being used to estimate errors in the response for each dosemeter type, used in the participating facilities, so that these can be taken into account in the estimates of cancer risk.
Turner, James D; Henshaw, Daryl S; Weller, Robert S; Jaffe, J Douglas; Edwards, Christopher J; Reynolds, J Wells; Russell, Gregory B; Dobson, Sean W
2018-05-08
To determine whether perineural dexamethasone prolongs peripheral nerve blockade (PNB) when measured objectively; and to determine if a 1 mg and 4 mg dose provide equivalent PNB prolongation compared to PNB without dexamethasone. Multiple studies have reported that perineural dexamethasone added to local anesthetics (LA) can prolong PNB. However, these studies have relied on subjective end-points to quantify PNB duration. The optimal dose remains unknown. We hypothesized that 1 mg of perineural dexamethasone would be equivalent in prolonging an adductor canal block (ACB) when compared to 4 mg of dexamethasone, and that both doses would be superior to an ACB performed without dexamethasone. This was a prospective, randomized, double-blind, placebo-controlled equivalency trial involving 85 patients undergoing a unicompartmental knee arthroplasty. All patients received an ACB with 20 ml of 0.25% bupivacaine with 1:400,000 epinephrine. Twelve patients had 0 mg of dexamethasone (placebo) added to the LA mixture; 36 patients had 1 mg of dexamethasone in the LA; and 37 patients had 4 mg of dexamethasone in the LA. The primary outcome was block duration determined by serial neurologic pinprick examinations. Secondary outcomes included time to first analgesic, serial pain scores, and cumulative opioid consumption. The 1 mg (31.8 ± 10.5 h) and 4 mg (37.9 ± 10 h) groups were not equivalent, TOST [Mean difference (95% CI); 6.1 (-10.5, -2.3)]. Also, the 4 mg group was superior to the 1 mg group (p-value = 0.035), and the placebo group (29.7 ± 6.8 h, p-value = 0.011). There were no differences in opioid consumption or time to analgesic request; however, some pain scores were significantly lower in the dexamethasone groups when compared to placebo. Dexamethasone 4 mg, but not 1 mg, prolonged the duration of an ACB when measured by serial neurologic pinprick exams. NCT02462148. Copyright © 2018 Elsevier Inc. All rights reserved.
Thomson, Rebecca L; Brinkworth, Grant D; Noakes, Manny; Buckley, Jonathan D
2016-02-01
Maintenance of muscle mass and strength into older age is critical to maintain health. The aim was to determine whether increased dairy or soy protein intake combined with resistance training enhanced strength gains in older adults. 179 healthy older adults (age 61.5 ± 7.4 yrs, BMI 27.6 ± 3.6 kg/m(2)) performed resistance training three times per week for 12 weeks and were randomized to one of three eucaloric dietary treatments which delivered >20 g of protein at each main meal or immediately after resistance training: high dairy protein (HP-D, >1.2 g of protein/kg body weight/d; ∼27 g/d dairy protein); high soy protein (HP-S, >1.2 g of protein/kg body weight/d; ∼27 g/d soy protein); usual protein intake (UP, <1.2 g of protein/kg body weight/d). Muscle strength, body composition, physical function and quality of life were assessed at baseline and 12 weeks. Treatments effects were analyzed using two-way ANOVA. 83 participants completed the intervention per protocol (HP-D = 34, HP-S = 26, UP = 23). Protein intake was higher in HP-D and HP-S compared with UP (HP-D 1.41 ± 0.14 g/kg/d, HP-S 1.42 ± 0.61 g/kg/d, UP 1.10 ± 0.10 g/kg/d; P < 0.001 treatment effect). Strength increased less in HP-S compared with HP-D and UP (HP-D 92.1 ± 40.8%, HP-S 63.0 ± 23.8%,UP 92.3 ± 35.4%; P = 0.002 treatment effect). Lean mass, physical function and mental health scores increased and fat mass decreased (P ≤ 0.006), with no treatment effect (P > 0.06). Increased soy protein intake attenuated gains in muscle strength during resistance training in older adults compared with increased intake of dairy protein or usual protein intake. ACTRN12612000177853 www.anzctr.org.au. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Response of a tissue equivalent proportional counter to neutrons
NASA Technical Reports Server (NTRS)
Badhwar, G. D.; Robbins, D. E.; Gibbons, F.; Braby, L. A.
2002-01-01
The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.
Characterization testing of Lockheed Martin high-power micro pulse tube cryocooler
NASA Astrophysics Data System (ADS)
McKinley, I. M.; Hummel, C. D.; Johnson, D. L.; Rodriguez, J. I.
2017-12-01
This paper describes the thermal vacuum, microphonics, magnetics, and radiation testing and results of a Lockheed Martin high-power micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 185 and 300 K. The cooler was driven with a Chroma 61602 AC power source for input powers ranging from 10 to 60 W and drive frequency between 115 and 140 Hz during thermal performance testing. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the microphonics of the cooler were measured with the cooler driven by Iris Technologies LCCE-2 and HP-LCCE drive electronics for input powers ranging from 10 to 60 W and drive frequency between 135 and 145 Hz. The exported forces were strongly dependent on input power while only weakly dependent on the drive frequency. Moreover, the exported force in the compressor axis was minimized by closed loop control with the HP-LCCE. The cooler also survived a 500 krad radiation dose while being continuously operated with 30 W of input power at 220 K heat rejection temperature in vacuum. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.
Balasubramani, Aparna; Rifai, Hanadi S
2015-10-01
Sewage sludge samples collected from 43 different domestic and industrial wastewater treatment plants and petrochemical industries that discharge to the Houston Ship Channel (HSC) were analyzed for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), which are highly toxic and carcinogenic towards humans and animals. The measured total PCDD/F toxic equivalency (TEQ) ranged between 0.73 and 7348.40 pg/g dry weight. The mean TEQ of PCDD/Fs in industrial sludge was approximately 40 times higher than that in sewage sludge. The PCDD homolog concentrations in the industrial samples were higher than those observed at the wastewater treatment plants by a factor of 10, with total heptachlorodibenzodioxin (HpCDD) exhibiting the maximum concentration in most of the samples. Among the PCDF homologs, total heptadichlorodibenzofuran (HpCDF) dominated the total homolog concentration in sludge from the wastewater treatment plants, whereas total tetradichlorodibenzofuran (TeCDF) dominated the industrial sludge samples. Overall, the total PCDD/F TEQ in sludge samples was much higher than that in effluent samples from the same facility. A linear correlation (R (2) = 0.62, p value < 0.068) was found indicating that sludge sampling can be used as a surrogate for effluent concentrations in wastewater treatment plants but not for industrial discharges.
Vitamin B12 supplement alleviates N'-nitrosodimethylamine-induced hepatic fibrosis in rats.
Ahmad, Areeba; Afroz, Nishat; Gupta, Umesh D; Ahmad, Riaz
2014-01-10
Abstract Context: Altered vitamin B 12 levels have been correlated with hepatotoxicity; however, further evidence is required to establish its protective role. Objective: To evaluate the effects of vitamin B 12 supplement in protecting N'-nitrosodimethylamine (NDMA)-induced hepatic fibrosis in Wistar rats. Materials and methods: Hepatic fibrosis was induced by administering NDMA in doses of 10 mg/kg body weight thrice a week for 21 days. Another group received equal doses (10 mg/kg body weight) of vitamin B 12 subsequent to NDMA treatment. Animals from either group were sacrificed weekly from the start of the treatment along with their respective controls. Progression of hepatic fibrosis, in addition to the effect of vitamin B 12 , was assessed biochemically for liver function biomarkers, liver glycogen, hydroxyproline (HP) and B 12 reserves along with histopathologically by hematoxylin and eosin (H & E) as well immunohistochemical staining for α-SMA expression. Results and discussion: Elevation in the levels of aminotransferases, SALP, total bilirubin and HP was observed in NDMA treated rats, which was concomitant with remarkable depletion in liver glycogen and B 12 reserves (p < 0.05). Liver biopsies also demonstrated disrupted lobular architecture, collagen amassing and intense fibrosis by NDMA treatment. Immunohistochemical staining showed the presence of activated stellate cells that was dramatically increased up to day 21 in fibrotic rats. Following vitamin B 12 treatment, liver function biomarkers, glycogen contents and hepatic vitamin B 12 reserves were restored in fibrotic rats, significantly. Vitamin B 12 administration also facilitated restoration of normal liver architecture. Conclusion: These findings provide interesting new evidence in favor of protective role for vitamin B 12 against NDMA-induced hepatic fibrosis in rats.
High- and Low-mobility Populations of HP1 in Heterochromatin of Mammalian CellsD⃞
Schmiedeberg, Lars; Weisshart, Klaus; Diekmann, Stephan; Meyer zu Hoerste, Gabriele; Hemmerich, Peter
2004-01-01
Heterochromatin protein 1 (HP1) is a conserved nonhistone chromosomal protein with functions in euchromatin and heterochromatin. Here we investigated the diffusional behaviors of HP1 isoforms in mammalian cells. Using fluorescence correlation spectroscopy (FCS) and fluorescence recovery after photobleaching (FRAP) we found that in interphase cells most HP1 molecules (50–80%) are highly mobile (recovery halftime: t1/2 ≈ 0.9 s; diffusion coefficient: D ≈ 0.6–0.7 μm2 s-1). Twenty to 40% of HP1 molecules appear to be incorporated into stable, slow-moving oligomeric complexes (t1/2 ≈ 10 s), and constitutive heterochromatin of all mammalian cell types analyzed contain 5–7% of very slow HP1 molecules. The amount of very slow HP1 molecules correlated with the chromatin condensation state, mounting to more than 44% in condensed chromatin of transcriptionally silent cells. During mitosis 8–14% of GFP-HP1α, but not the other isoforms, are very slow within pericentromeric heterochromatin, indicating an isoform-specific function of HP1α in heterochromatin of mitotic chromosomes. These data suggest that mobile as well as very slow populations of HP1 may function in concert to maintain a stable conformation of constitutive heterochromatin throughout the cell cycle. PMID:15064352
Wu, Zhi-shuang; Zhang, Min; Wang, Shao-jin
2012-08-30
High-pressure (HP) inert gas processing causes inert gas and water molecules to form clathrate hydrates that restrict intracellular water activity and enzymatic reactions. This technique can be used to preserve fruits and vegetables. In this study, minimally processed (MP) pineapples were treated with HP (∼10 MPa) argon (Ar) and nitrogen (N) for 20 min. The effects of these treatments on respiration, browning and antioxidant potential of MP pineapples were investigated after cutting and during 20 days of storage at 4 °C. Lower respiration rate and ethylene production were found in HP Ar- and HP N-treated samples compared with control samples. HP Ar and HP N treatments effectively reduced browning and loss of total phenols and ascorbic acid and maintained antioxidant capacity of MP pineapples. They did not cause a significant decline in tissue firmness or increase in juice leakage. HP Ar treatments had greater effects than HP N treatments on reduction of respiration rate and ethylene production and maintenance of phenolic compounds and DPPH(•) and ABTS(•+) radical-scavenging activities. Both HP Ar and HP N processing had beneficial effects on MP pineapples throughout 20 days of storage at 4 °C. Copyright © 2012 Society of Chemical Industry.
Assessment of medical occupational radiation doses in Costa Rica.
Mora, P; Acuña, M
2011-09-01
Participation of the University of Costa Rica (UCR) in activities in an IAEA Regional Project RLA/9/066 through training, equipment and expert missions, has enabled to setting up of a national personal monitoring laboratory. Since 2007, the UCR has been in charge of monitoring around 1800 medical radiation workers of the Social Security System. Individual external doses are measured with thermoluminescent dosemeter using a Harshaw 6600 Plus reader. The service has accreditation with ISO/IEC 17025:2005. Distribution of monitored medical personnel is as follows: 83 % in diagnostic radiology, 6 % in nuclear medicine and 6 % in radiotherapy. Preliminary values for the 75 percentile of annual H(p)(10) in mSv are: radiology 0.37; interventional radiology 0.41; radiotherapy 0.53 and nuclear medicine 1.55. The service provided by the UCR in a steady and reliable way can help to implement actions to limit the doses received by the medical workers and optimise their radiation protection programs.
Arceo-Gómez, Gerardo; Jameel, Mohammad I; Ashman, Tia-Lynn
2018-05-01
Studies on the effects of heterospecific pollen (HP) transfer have been focused mainly on insect-pollinated species, despite evidence of insect visitation to wind-pollinated species and transfer of their pollen onto stigmas of insect-pollinated plants. Thus, the potential consequences of HP transfer from wind-pollinated species remain largely unknown. Furthermore, accumulation of pesticide residues in pollen of wind-pollinated crops has been documented, but its potential effects on wild plant species via HP transfer have not been tested. We evaluated the effect of wind-dispersed Zea mays pollen on pollen tube growth of the insect-pollinated Mimulus nudatus via hand pollinations. We further evaluated whether pesticide-contaminated Z. mays pollen has larger effects on M. nudatus pollen success than non-contaminated Z. mays pollen. We found a significant negative effect of Z. mays pollen on M. nudatus pollen tube growth even when deposited in small amounts. However, we did not observe any difference in the magnitude of this effect between pesticide-laden Z. mays pollen and non-contaminated Z. mays pollen. Our results suggest that wind-pollinated species can have negative effects as HP donors on insect-pollinated recipients. Thus, their role in shaping co-flowering interactions for wind- and insect-pollinated species deserves more attention. Although we did not find evidence that pesticide contamination increased HP effects, we cannot fully rule out the existence of such an effect, because pollen load and thus the pesticide dose applied to stigmas was low. This result should be confirmed using other HP donors and across a range of HP loads, pesticide types, and concentrations. © 2018 Botanical Society of America.
Ono, Kaoru; Endo, Satoru; Tanaka, Kenichi; Hoshi, Masaharu; Hirokawa, Yutaka
2010-01-01
Purpose: In this study, the authors evaluated the accuracy of dose calculations performed by the convolution∕superposition based anisotropic analytical algorithm (AAA) in lung equivalent heterogeneities with and without bone equivalent heterogeneities. Methods: Calculations of PDDs using the AAA and Monte Carlo simulations (MCNP4C) were compared to ionization chamber measurements with a heterogeneous phantom consisting of lung equivalent and bone equivalent materials. Both 6 and 10 MV photon beams of 4×4 and 10×10 cm2 field sizes were used for the simulations. Furthermore, changes of energy spectrum with depth for the heterogeneous phantom using MCNP were calculated. Results: The ionization chamber measurements and MCNP calculations in a lung equivalent phantom were in good agreement, having an average deviation of only 0.64±0.45%. For both 6 and 10 MV beams, the average deviation was less than 2% for the 4×4 and 10×10 cm2 fields in the water-lung equivalent phantom and the 4×4 cm2 field in the water-lung-bone equivalent phantom. Maximum deviations for the 10×10 cm2 field in the lung equivalent phantom before and after the bone slab were 5.0% and 4.1%, respectively. The Monte Carlo simulation demonstrated an increase of the low-energy photon component in these regions, more for the 10×10 cm2 field compared to the 4×4 cm2 field. Conclusions: The low-energy photon by Monte Carlo simulation component increases sharply in larger fields when there is a significant presence of bone equivalent heterogeneities. This leads to great changes in the build-up and build-down at the interfaces of different density materials. The AAA calculation modeling of the effect is not deemed to be sufficiently accurate. PMID:20879604
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Y; Lee, D; Jung, H
2014-06-01
Purpose: In this study, the dose responses of the MAGIC gel with various concentrations and type of saccharide are examined to clarify the roles of mono and disaccharide in the polymerization process. Then we focused on the tissue equivalence and dose sensitivity of MAGIC gel dosimeters. Methods: The gel is composed of HPLC, 8% gelatin, 2 × 10-3 M L-ascorbic acid, 1.8 × 10-2 M hydroquinone, 8 × 10-5 M copper(II)sulfate and 9% methacrylic acid, new polymer gels are synthesized by adding glucose(monosaccharide), sucrose(disaccharide) and urea in the concentration range of 5∼35%. For irradiation of the gel, cesium-137 gamma-ray irradiatormore » was used, radiation dose was delivered from 5∼50 Gy. MRI images of the gel were acquired by using a 3.0 T MRI system. Results: When saccharide and urea were added, the O/C, O/N and C/N ratios agreed with those of soft tissue with 1.7%. The dose-response of glucose and sucrose gel have slope-to-intercept ratio of 0.044 and 0.283 respectively. The slope-to-ratio is one important determinant of gel sensitivity. R-square values of glucose and sucrose gel dosimeters were 0.984 and 0.994 respectively. Moreover when urea were added, the slope-to-intercept ratio is 0.044 and 0.073 respectively. R-square values of mono and disaccharide gel were 0.973 and 0.989 respectively. When a saccharide is added into the MAGIC gel dosimeter, dose sensitivity is increased. However when urea were added, dose sensitivity is slightly decreased. Conclusion: In this study, it was possible to obtain the following conclusions by looking at the dose response characteristics after adding mono-, di-saccharide and urea to a MAGIC gel dosimeter. Saccharide was a tendency of increasing dose sensitivity with disaccharide. Sa.ccharide is cost effective, safe, soft tissue equivalent, and can be used under various experimental conditions, making it a suitable dosimeter for some radiotherapy applications.« less
NASA Technical Reports Server (NTRS)
Kim, M.Y.; Cucinotta, F.A.
2005-01-01
Radiation protection practices define the effective dose as a weighted sum of equivalent dose over major sites for radiation cancer risks. Since a crew personnel dosimeter does not make direct measurement of effective dose, it has been estimated with skin-dose measurements and radiation transport codes for ISS and STS missions. The Phantom Torso Experiment (PTE) of NASA s Operational Radiation Protection Program has provided the actual flight measurements of active and passive dosimeters which were placed throughout the phantom on STS-91 mission for 10 days and on ISS Increment 2 mission. For the PTE, the variation in organ doses, which is resulted by the absorption and the changes in radiation quality with tissue shielding, was considered by measuring doses at many tissue sites and at several critical body organs including brain, colon, heart, stomach, thyroid, and skins. These measurements have been compared with the organ dose calculations obtained from the transport models. Active TEPC measurements of lineal energy spectra at the surface of the PTE also provided the direct comparison of galactic cosmic ray (GCR) or trapped proton dose and dose equivalent. It is shown that orienting the phantom body as actual in ISS is needed for the direct comparison of the transport models to the ISS data. One of the most important observations for organ dose equivalent of effective dose estimates on ISS is the fractional contribution from trapped protons and GCR. We show that for most organs over 80% is from GCR. The improved estimation of effective doses for radiation cancer risks will be made with the resultant tissue weighting factors and the modified codes.
Theodosiadou, E; Goulas, P; Kouskoura, Th; Smokovitis, A
2004-01-01
Synchronisation of oestrus in Karagouniki ewes by administration of the standard dose of progesterone results in lower fertility than observed when these ewes ovulate naturally. This suggests that the optimum dose of progesterone may be breed dependent. The exogenous progesterone may perturb the concentrations of oestradiol-17beta and progesterone in blood plasma and the oviductal wall. This possibility was investigated using Karagouniki ewes allocated at random to three treatments (n=4 per treatment). Ewes were allowed to exhibit natural oestrus (N) or oestrus was synchronised by administration of 250 mg (LP) or 375 mg (HP) progesterone (subcutaneous implants) followed by PMSG at 8 mg/kg live weight i.m. 14 days later. Oestrus was observed using teaser rams. Blood samples were collected for plasma oestradiol-17beta and progesterone assay from the onset to the end of oestrus at 2 h intervals. The uterus of each ewe was recovered at the end of oestrus and samples of the oviductal wall were taken from both oviducts and prepared, separately, for progesterone and oestradiol-17beta assay. Statistical analysis was performed using univariate analysis of variance. Plasma oestradiol-17beta concentrations from the onset to the end of oestrus were highest for N ewes and lowest for HP ewes with the values for LP ewes occupying an intermediate position. The differences were significant (P<0.05) between HP and the other two treatments from 4 to 12 h after the onset of oestrus and then between all treatments until the end of oestrus. Plasma progesterone levels were similar and fairly constant from the onset to the end of oestrus for N and LP. The plasma progesterone levels for HP were significantly (P<0.05) higher than for the other two treatments throughout oestrus. In oviductal wall samples, the oestradiol-17beta concentration was significantly (P<0.05) higher for N ewes than for synchronised ewes and the levels were similar for LP and HP ewes. The concentration of oestradiol-17beta differed (P<0.05) between right and left oviducts for N ewes but not for ewes of either of the synchronised oestrus treatments. Progesterone concentrations in oviductal wall samples were highest (P<0.05) for HP ewes and the values for N and LP ewes were similar. The concentration of progesterone did not differ between right and left oviductal wall samples within treatments. It was concluded that the higher dose of exogenous progesterone perturbed the levels of oestradiol-17beta and progesterone in blood plasma and the oviductal wall, and this could explain the lower levels of fertility (relative to naturally occurring oestrus) observed when this protocol is used for Karagouniki ewes in practice.
Diabetic patients infected with helicobacter pylori have a higher Insulin Resistance Degree
Vafaeimanesh, Jamshid; Bagherzadeh, Mohammad; Heidari, Akram; Motii, Fatemeh; Parham, Mahmoud
2014-01-01
Background: The association of H.pylori (HP) and insulin resistance degree (IR) has not been evaluated in the diabetic patients so far. In this study, we evaluated the association between HP seropositivity and the homeostatic model assessment for insulin resistance (HOMA-IR) in diabetic patients. Methods: In this study, 211 diabetic patients admitted to the endocrinology clinic of Shahid Beheshti Hospital of Qom for routine diabetic check-ups were evaluated. The patients were divided into HP+ and HP- groups based on the seropositivity of helicobacter pylori IgG antibody. The serum H. pylori IgG antibody, blood sugar, serum insulin, HbA1c, LDL, HDL, cholesterol, triglyceride, HOMA-IR and BMI were measured. Results: The mean age of 72 HP- patient was 51.5±8.3 and 139 HP+ subjects was 53.5±9 years (P=0.128). The mean HDL in HP- cases was 69.2±29.2 mg/dl and for HP+ cases was 60.7±26.7 mg/dl (P=0.037). The mean serum insulin in HP- was 60.97±5.64 and HP+ subjects was 10.12±7.72IU/ml (P=0.002). The Homa-IR degree for HP- cases was 3.2±3.3 and for HP+ cases was 4.5±3.8 (P=0.013). There were no significant differences between these groups according to the short-term or the long-term indices of glycemic control as well as most of the diabetic risk factors or complications. The treatment type was also not significantly different between these groups. Conclusion: It seems that the HP+ diabetic patients require higher levels of serum insulin to reach the same degree of glycemic control compared to the HP- ones. PMID:25202440
NASA Astrophysics Data System (ADS)
Hälg, R. A.; Besserer, J.; Boschung, M.; Mayer, S.; Lomax, A. J.; Schneider, U.
2014-05-01
In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.
Hälg, R A; Besserer, J; Boschung, M; Mayer, S; Lomax, A J; Schneider, U
2014-05-21
In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.
Negative-tone imaging with EUV exposure toward 13nm hp
NASA Astrophysics Data System (ADS)
Tsubaki, Hideaki; Nihashi, Wataru; Tsuchihashi, Toru; Yamamoto, Kei; Goto, Takahiro
2016-03-01
Negative-tone imaging (NTI) with EUV exposure has major advantages with respect to line-width roughness (LWR) and resolution due in part to polymer swelling and favorable dissolution mechanics. In NTI process, both resist and organic solvents play important roles in determining lithography performances. The present study describes novel chemically amplified resist materials based on NTI technology with EUV using a specific organic solvents. Lithographic performances of NTI process were described in this paper under exposures using ASML NXE:3300 EUV scanner at imec. It is emphasized that 14 nm hp was nicely resolved under exposure dose of 37 mJ/cm2 without any bridge and collapse, which are attributed to the low swelling character of NTI process. Although 13 nm hp resolution was potentially obtained, a pattern collapse still restricts its resolution in case coating resist film thickness is 40 nm. Dark mask limitation due mainly to mask defectivity issue makes NTI with EUV favorable approach for printing block mask to produce logic circuit. A good resolution of CD-X 21 nm/CD-Y 32 nm was obtained for block mask pattern using NTI with usable process window and dose of 49 mJ/cm2. Minimum resolution now reaches CD-X 17 nm / CD-Y 23 nm for the block. A 21 nm block mask resolution was not affected by exposure dose and explored toward low dose down to 18 mJ/cm2 by reducing quencher loading. In addition, there was a negligible amount of increase in LCDU for isolated dot pattern when decreasing exposure dose from 66 mJ/cm2 to 24 mJ/cm2. On the other hand, there appeared tradeoff relationship between LCDU and dose for dense dot pattern, indicating photon-shot noise restriction, but strong dependency on patterning features. Design to improve acid generation efficiency was described based on acid generation mechanism in traditional chemically amplified materials which contains photo-acid generator (PAG) and polymer. Conventional EUV absorber comprises of organic compounds is expected to have 1.6 times higher EUV absorption than polyhydroxystyrene based on calculation. However, observed value of acid amount was comparable or significantly worse than polyhydroxystyrene.
Estimation of eye lens doses received by pediatric interventional cardiologists.
Alejo, L; Koren, C; Ferrer, C; Corredoira, E; Serrada, A
2015-09-01
Maximum Hp(0.07) dose to the eye lens received in a year by the pediatric interventional cardiologists has been estimated. Optically stimulated luminescence dosimeters were placed on the eyes of an anthropomorphic phantom, whose position in the room simulates the most common irradiation conditions. Maximum workload was considered with data collected from procedures performed in the Hospital. None of the maximum values obtained exceed the dose limit of 20 mSv recommended by ICRP. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hennebert, Pierre; van der Sloot, Hans A; Rebischung, Flore; Weltens, Reinhilde; Geerts, Lieve; Hjelmar, Ole
2014-10-01
Hazard classification of waste is a necessity, but the hazard properties (named "H" and soon "HP") are still not all defined in a practical and operational manner at EU level. Following discussion of subsequent draft proposals from the Commission there is still no final decision. Methods to implement the proposals have recently been proposed: tests methods for physical risks, test batteries for aquatic and terrestrial ecotoxicity, an analytical package for exhaustive determination of organic substances and mineral elements, surrogate methods for the speciation of mineral elements in mineral substances in waste, and calculation methods for human toxicity and ecotoxicity with M factors. In this paper the different proposed methods have been applied to a large assortment of solid and liquid wastes (>100). Data for 45 wastes - documented with extensive chemical analysis and flammability test - were assessed in terms of the different HP criteria and results were compared to LoW for lack of an independent classification. For most waste streams the classification matches with the designation provided in the LoW. This indicates that the criteria used by LoW are similar to the HP limit values. This data set showed HP 14 'Ecotoxic chronic' is the most discriminating HP. All wastes classified as acute ecotoxic are also chronic ecotoxic and the assessment of acute ecotoxicity separately is therefore not needed. The high number of HP 14 classified wastes is due to the very low limit values when stringent M factors are applied to total concentrations (worst case method). With M factor set to 1 the classification method is not sufficiently discriminating between hazardous and non-hazardous materials. The second most frequent hazard is HP 7 'Carcinogenic'. The third most frequent hazard is HP 10 'Toxic for reproduction' and the fourth most frequent hazard is HP 4 "Irritant - skin irritation and eye damage". In a stepwise approach, it seems relevant to assess HP 14 first, then, if the waste is not classified as hazardous, to assess subsequently HP 7, HP 10 and HP 4, and then if still not classified as hazardous, to assess the remaining properties. The elements triggering the HP 14 classification in order of importance are Zn, Cu, Pb, Cr, Cd and Hg. Progress in the speciation of Zn and Cu is essential for HP 14. Organics were quantified by the proposed method (AFNOR XP X30-489) and need no speciation. Organics can contribute significantly to intrinsic toxicity in many waste materials, but they are only of minor importance for the assessment of HP 14 as the metal concentrations are the main HP 14 classifiers. Organic compounds are however responsible for other toxicological characteristics (hormone disturbance, genotoxicity, reprotoxicity…) and shall be taken into account when the waste is not HP 14 classified. Copyright © 2014 Elsevier Ltd. All rights reserved.
Thor, P; Lorens, K; Tabor, S; Herman, R; Konturek, J W; Konturek, S J
1996-09-01
Helicobacter pylori (Hp) infection has been shown to affect gastric acid secretion and the somatostatin-gastrin ratio but its effects on gastric motility have not been evaluated. This study was carried out in 12 patients (10 males and 2 females, mean age 33 +/- 6 yrs) who underwent endoscopy and Campylobacter-like Organism (CLO)-test. All patients were found initially to be Hp positive according to CLO-test. Gastric emptying was evaluated by measuring antral diameter with ultrasonography (Hitachi EUB 240) in fasted and fed patients. Electrogastrography (EGG) with antral manometry were done 5 h before and 4 h after a meal before the therapy and one month after the eradication with triple therapy (lanzoprazole 30 mg daily- 2 x 250 mg clarithromycin 500 mg t.i.d.-3 x 500 mg and metronidazole 500 mg b.i.d.-2 x 500 mg). In Hp positive patients before the triple therapy the mean fasted antral diameter was 4.3 cm2, initial EGG showed significant dysrhythmia of electrical control activity (ECA) with tachygastria up to 25% of recording time in 9 of 12 Hp positive patients without normal increase of the power of signal in any of tested subjects. In 7 Hp positive fasted antral manometry failed to exhibit gastric phases III of the migrating motor complex (MMC). Hp eradication was accomplished in 10 of 12 examined patients and this was followed by a decrease in tachygastria to 3 cpm rhythm with an increase of the ECA power after meal. Phase III of MMC was observed again in 7 Hp negative patients with a decrease of fasted antral diameter (p < 0.05). Fasted and fed antral motility pattern increased after eradication. Two patients remained Hp positive after standard therapy. We conclude that most symptomatic non ulcer dyspeptic Hp positive patients show changes in ECA and antral hypomotility that are associated with Hp infections.
Effect of laser activated bleaching on the chemical stability and morphology of intracoronal dentin.
Lopes, Fabiane Carneiro; Roperto, Renato; Akkus, Anna; Akkus, Ozan; Palma-Dibb, Regina Guenka; de Sousa-Neto, Manoel Damião
2018-02-01
To evaluate the effect of the bleaching with 35% hydrogen peroxide either activated or not by a 970nm diode laser on the chemical stability and dentin surface morphology of intracoronary dentin. Twenty-seven slabs of intracoronary dentin specimens (3×3mm) were distributed into three groups (n=9), according to surface treatment: HP - 35% hydrogen peroxide (1×4'), DL - 970nm diode laser (1×30"/0,8W/10Hz), HP+DL - 35% HP activated with 970nm diode laser (1×30"/0,8W/10Hz leaving the gel in contact to the surface for 4' after activation). Three Raman spectra from each fragment were obtained to calculate the mean intensity of peaks of inorganic component (a.u.), organic collagen content (a.u.), and the ratio of inorganic/organic content, before and after treatment. Analyses of the samples by confocal laser microscopy were performed to evaluate the surface roughness, percentage of tubules, perimeter and area percentage of tubules, before and after treatment. Data were analyzed by Kruskal-Wallis, Dunn's, and Wilcoxon test (P<0.05). Data analysis showed that HP+DL did not change the inorganic content peaks 8.31 [29.78] or the inorganic/organic ratio 3.37 [14.67] (P>0.05). Similarly, DL did not affect the chemical stability of the dentin surface (P>0.05). However, HP significantly increased inorganic content peaks 10.87 [22.62], as well as the inorganic/organic ratio 6.25 [27.78] (P<0.05). Regarding the morphological alterations, all surface treatments increase tubules exposure; HP treatment significantly increases perimeter and area percentage; and HP+DL increases surface roughness. Bleaching HP combined with DL offers an improvement in terms of intracoronal dentin surface protection, yielding better maintenance of dentin chemical stability and morphology. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development and analytical performance evaluation of FREND-SAA and FREND-Hp
NASA Astrophysics Data System (ADS)
Choi, Eunha; Seong, Jihyun; Lee, Seiyoung; Han, Sunmi
2017-07-01
The FREND System is a portable cartridge reader, quantifying analytes by measuring laser-induced fluorescence in a single-use reagent cartridge. The objective of this study was to evaluate FREND-SAA and FREND-Hp assays. The FREND-SAA and Hp assays were standardized to the WHO and IFCC reference materials. Analytical performance studies of Precision, Linearity, Limits of Detections, Interferences, and Method Comparisons for both assays were performed according to the CLSI guidelines. Both assays demonstrated acceptable imprecision of %CV in three different levels of samples. The linearity of the assays was found to be acceptable (SAA 5 150 mg/L, Hp 30 400 mg/dL). The detection limits were 3.8 mg/L (SAA) and 10.2 mg/dL (Hp). No significant interference and no significant deviation from linearity was found in the both comparison studies. In conclusion, NanoEnTek's FREND-SAA and Hp assays represent rapid, accurate and convenient means to quantify SAA and Hp in human serum on FREND system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma Lijun, E-mail: lijunma@radonc.ucsf.ed; Sahgal, Arjun; Descovich, Martina
2010-03-01
Purpose: To investigate whether dose fall-off characteristics would be significantly different among intracranial radiosurgery modalities and the influence of these characteristics on fractionation schemes in terms of normal tissue sparing. Methods and Materials: An analytic model was developed to measure dose fall-off characteristics near the target independent of treatment modalities. Variations in the peripheral dose fall-off characteristics were then examined and compared for intracranial tumors treated with Gamma Knife, Cyberknife, or Novalis LINAC-based system. Equivalent uniform biologic effective dose (EUBED) for the normal brain tissue was calculated. Functional dependence of the normal brain EUBED on varying numbers of fractions (1more » to 30) was studied for the three modalities. Results: The derived model fitted remarkably well for all the cases (R{sup 2} > 0.99). No statistically significant differences in the dose fall-off relationships were found between the three modalities. Based on the extent of variations in the dose fall-off curves, normal brain EUBED was found to decrease with increasing number of fractions for the targets, with alpha/beta ranging from 10 to 20. This decrease was most pronounced for hypofractionated treatments with fewer than 10 fractions. Additionally, EUBED was found to increase slightly with increasing number of fractions for targets with alpha/beta ranging from 2 to 5. Conclusion: Nearly identical dose fall-off characteristics were found for the Gamma Knife, Cyberknife, and Novalis systems. Based on EUBED calculations, normal brain sparing was found to favor hypofractionated treatments for fast-growing tumors with alpha/beta ranging from 10 to 20 and single fraction treatment for abnormal tissues with low alpha/beta values such as alpha/beta = 2.« less
Ultra-Efficient and Power Dense Electric Motors for U. S. Industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melfi, Michael J.; Schiferl, Richard F.; Umans, Stephen D.
2013-03-12
The primary purpose of this project was to combine the ease-of-installation and ease-of-use attributes of industrial induction motors with the low-loss and small size and weight advantages of PM motors to create an ultra-efficient, high power density industrial motor that can be started across-the-line or operated from a standard, Volts/Hertz drive without the need for a rotor position feedback device. PM motor products that are currently available are largely variable speed motors that require a special adjustable speed drive with rotor position feedback. The reduced size and weight helps to offset the magnet cost in order make these motors commerciallymore » viable. The scope of this project covers horsepower ratings from 20 ? 500. Prototypes were built and tested at ratings ranging from 30 to 250 HP. Since fans, pumps and compressors make up a large portion of industrial motor applications, the motor characteristics are tailored to those applications. Also, since there is extensive use of adjustable frequency inverters in these applications, there is the opportunity to design for an optimal pole number and operate at other than 60 Hz frequency when inverters are utilized. Designs with four and eight pole configurations were prototyped as part of this work. Four pole motors are the most commonly used configuration in induction motors today. The results of the prototype design, fabrication, and testing were quite successful. The 50 HP rating met all of the design goals including efficiency and power density. Tested values of motor losses at 50 HP were 30% lower than energy efficient induction motors and the motor weight is 35% lower than the energy efficient induction motor of the same rating. Further, when tested at the 30 HP rating that is normally built in this 286T frame size, the efficiency far exceeds the project design goals with 30 HP efficiency levels indicating a 55% reduction in loss compared to energy efficient motors with a motor weight that is a few percentage points lower than the energy efficient motor. This 30 HP rating full load efficiency corresponds to a 46% reduction in loss compared to a 30 HP NEMA Premium? efficient motor. The cost goals were to provide a two year or shorter efficiency-based payback of a price premium associated with the magnet cost in these motors. That goal is based on 24/7 operation with a cost of electricity of 10 cents per kW-hr. Similarly, the 250 HP prototype efficiency testing was quite successful. In this case, the efficiency was maximized with a slightly less aggressive reduction in active material. The measured full load efficiency of 97.6% represents in excess of a 50% loss reduction compared to the equivalent NEMA Premium Efficiency induction motor. The active material weight reduction was a respectable 14.5% figure. This larger rating demonstrated both the scalability of this technology and also the ability to flexibly trade off power density and efficiency. In terms of starting performance, the 30 ? 50 HP prototypes were very extensively tested. The demonstrated capability included the ability to successfully start a load with an inertia of 25 times the motor?s own inertia while accelerating against a load torque following a fan profile at the motor?s full nameplate power rating. This capability will provide very wide applicability of this motor technology. The 250 HP prototype was also tested for starting characteristics, though without a coupled inertia and load torque. As a result it was not definitively proven that the same 25 times the motor?s own inertia could be started and synchronized successfully at 250 HP. Finite element modeling implies that this load could be successfully started, but it has not yet been confirmed by a test.« less
Dosimetry study for a new in vivo X-ray fluorescence (XRF) bone lead measurement system
NASA Astrophysics Data System (ADS)
Nie, Huiling; Chettle, David; Luo, Liqiang; O'Meara, Joanne
2007-10-01
A new 109Cd γ-ray induced bone lead measurement system has been developed to reduce the minimum detectable limit (MDL) of the system. The system consists of four 16 mm diameter detectors. It requires a stronger source compared to the "conventional" system. A dosimetry study has been performed to estimate the dose delivered by this system. The study was carried out by using human-equivalent phantoms. Three sets of phantoms were made to estimate the dose delivered to three age groups: 5-year old, 10-year old and adults. Three approaches have been applied to evaluate the dose: calculations, Monte Carlo (MC) simulations, and experiments. Experimental results and analytical calculations were used to validate MC simulation. The experiments were performed by placing Panasonic UD-803AS TLDs at different places in phantoms that representing different organs. Due to the difficulty of obtaining the organ dose and the whole body dose solely by experiments and traditional calculations, the equivalent dose and effective dose were calculated by MC simulations. The result showed that the doses delivered to the organs other than the targeted lower leg are negligibly small. The total effective doses to the three age groups are 8.45/9.37 μSv (female/male), 4.20 μSv, and 0.26 μSv for 5-year old, 10-year old and adult, respectively. An approval to conduct human measurements on this system has been received from the Research Ethics Board based on this research.
NASA Technical Reports Server (NTRS)
Foelsche, T.; Mendell, R. B.; Wilson, J. W.; Adams, R. R.
1974-01-01
Results of the NASA Langley-New York University high-altitude radiation study are presented. Measurements of the absorbed dose rate and of secondary fast neutrons (1 to 10 MeV energy) during the years 1965 to 1971 are used to determine the maximum radiation exposure from galactic and solar cosmic rays of supersonic transport (SST) and subsonic jet occupants. The maximum dose equivalent rates that the SST crews might receive turn out to be 13 to 20 percent of the maximum permissible dose rate (MPD) for radiation workers (5 rem/yr). The exposure of passengers encountering an intense giant-energy solar particle event could exceed the MPD for the general population (0.5 rem/yr), but would be within these permissible limits if in such rare cases the transport descends to subsonic altitude; it is in general less than 12 percent of the MPD. By Monte Carlo calculations of the transport and buildup of nucleons in air for incident proton energies E of 0.02 to 10 GeV, the measured neutron spectra were extrapolated to lower and higher energies and for galactic cosmic rays were found to continue with a relatively high intensity to energies greater than 400 MeV, in a wide altitude range. This condition, together with the measured intensity profiles of fast neutrons, revealed that the biologically important fast and energetic neutrons penetrate deep into the atmosphere and contribute approximately 50 percent of the dose equivalant rates at SST and present subsonic jet altitudes.
Anti-tumour activity of two novel compounds in cisplatin-resistant testicular germ cell cancer.
Nitzsche, B; Gloesenkamp, C; Schrader, M; Hoffmann, B; Zengerling, F; Balabanov, S; Honecker, F; Höpfner, M
2012-11-20
Resistance to cisplatin-based chemotherapy is associated with poor prognosis in testicular germ cell cancer, emphasising the need for new therapeutic approaches. In this respect, the therapeutic concept of anti-angiogenesis is of particular interest. In a previous study, we presented two novel anti-angiogenic compounds, HP-2 and HP-14, blocking the tyrosine kinase activity of angiogenic growth factor receptors, such as vascular endothelial growth factor receptor-2 (VEGFR-2), and related signalling pathways in testicular cancer. In this study, we investigated the efficacy of these new compounds in platinum-resistant testicular germ cell tumours (TGCTs), in vitro and in vivo. Drug-induced changes in cell proliferation of the cisplatin-sensitive TGCT cell line 2102EP and its cisplatin-resistant counterpart 2102EP-R, both expressing the VEGFR-2, were evaluated by crystal violet staining. Both compounds inhibited the growth of cisplatin-resistant TGCT cells in a dose-dependent manner. In combination experiments with cisplatin, HP-14 revealed additive growth-inhibitory effects in TGCT cells, irrespective of the level of cisplatin resistance. Anti-angiogenic effects of HP compounds were confirmed by tube formation assays with freshly isolated human umbilical vein endothelial cells. Using TGCT cells inoculated onto the chorioallantoic membrane of fertilised chicken eggs (chicken chorioallantoic membrane assay), the anti-angiogenic and anti-proliferative potency of the novel compounds was also demonstrated in vivo. Gene expression profiling revealed changes in the expression pattern of genes related to DNA damage detection and repair, as well as in chaperone function after treatment with both cisplatin and HP-14, alone or in combination. This suggests that HP-14 can revert the lost effectiveness of cisplatin in the resistant cells by altering the expression of critical genes. The novel compound HP-14 effectively inhibits the growth of cisplatin-resistant TGCT cells and suppresses tumour angiogenesis. Thus, HP-14 may be an interesting new agent that should be further explored for TGCT treatment, especially in TGCTs that are resistant to cisplatin.
Lützen, Ulf; Zhao, Yi; Marx, Marlies; Imme, Thea; Assam, Isong; Siebert, Frank‐Andre; Culman, Juraj
2016-01-01
Radiation Protection in Radiology, Nuclear Medicine and Radio Oncology is of the utmost importance. Radioiodine therapy is a frequently used and effective method for the treatment of thyroid disease. Prior to each therapy the radioactivity of the [ 131I]‐capsule must be determined to prevent misadministration. This leads to a significant radiation exposure to the staff. We describe an alternative method, allowing a considerable reduction of the radiation exposure. Two [ 131I]‐capsules (A01=2818.5; A02=73.55.0 MBq) were measured multiple times in their own delivery lead containers — that is to say, [ 131I]‐capsules remain inside the containers during the measurements (shielded measurement) using a dose calibrator and a well‐type and a thyroid uptake probe. The results of the shielded measurements were correlated linearly with the [ 131I]‐capsules radioactivity to create calibration curves for the used devices. Additional radioactivity measurements of 50 [ 131I]‐capsules of different radioactivities were done to validate the shielded measuring method. The personal skin dose rate (HP(0.07)) was determined using calibrated thermo luminescent dosimeters. The determination coefficients for the calibration curves were R2>0.9980 for all devices. The relative uncertainty of the shielded measurement was <6.8%. At a distance of 10 cm from the unshielded capsule the HP(0.07) was 46.18 μSv/(GBq⋅s), and on the surface of the lead container containing the [ 131I]‐capsule the HP(0.07) was 2.99 and 0.27 μSv/(GBq⋅s) for the two used container sizes. The calculated reduction of the effective dose by using the shielded measuring method was, depending on the used container size, 74.0% and 97.4%, compared to the measurement of the unshielded [ 131I]‐capsule using a dose calibrator. The measured reduction of the effective radiation dose in the practice was 56.6% and 94.9 for size I and size II containers. The shielded [ 131I]‐capsule measurement reduces the radiation exposure to the staff significantly and offers the same accuracy of the unshielded measurement in the same amount of time. In order to maintain the consistency of the measuring method, monthly tests have to be done by measuring a [ 131I]‐capsule with known radioactivity. PACS number(s): 93.85.Np, 92.20.Td, 87.50.yk, 87.53.Bn PMID:27455475
Liu, Lunzhi; Ding, Guohua
2015-04-01
The aim of the present study was to investigate the impact of three different blood purification methods, hemoperfusion (HP), continuous blood purification (CBP), and on-line high-volume hemodiafiltration (OL-HDF), on the survival rate of patients with acute severe organophosphorus pesticide poisoning (ASOPP), as well as on major pro-inflammatory (interleukin [IL]-1, IL-6, tumor necrosis factor-α [TNF-α]) and anti-inflammatory (IL-10) cytokines in the serum. Eighty-one ASOPP patients were randomly divided into three groups: HP (N = 23), HP + CBP (N = 26), HP + OL-HD (N = 32). Serum IL-1, IL-6, TNF-α, and IL-10 levels were assessed by ELISA before treatment and at 24 and 48 h post-treatment and survival rates were determined. Patient survival rate was significantly higher in OL-HDF and CBP treated patients compared with HP group (P < 0.05). A significantly greater clearance effect in serum IL-1, IL-6, and TNF-α levels at 24 and 48 h post-treatment was observed in CBP and OL-HDF groups compared with the HP group (P < 0.05). The levels of serum anti-inflammatory cytokine IL-10 increased significantly in CBP and OL-HDF groups compared with the HP group (P < 0.05 at 48 h post-treatment). In addition, OL-HDF treatment achieved similar changes in serum TNF-α, IL-1, IL-6 and IL-10 levels as CBP (P > 0.05). Compared with the HP method, CBP or OL-HDF combined with HP can rapidly clear inflammatory cytokines, reduce systemic inflammatory response syndrome, and improve the survival of ASOPP patients. Compared with CBP, OL-HDF is an economical and effective method to treat ASOPP with less technical difficulty and more suitability for rural areas and primary hospitals. © 2014 The Authors. Therapeutic Apheresis and Dialysis © 2014 International Society for Apheresis.
NASA Astrophysics Data System (ADS)
Cassola, V. F.; Milian, F. M.; Kramer, R.; de Oliveira Lira, C. A. B.; Khoury, H. J.
2011-07-01
Computational anthropomorphic human phantoms are useful tools developed for the calculation of absorbed or equivalent dose to radiosensitive organs and tissues of the human body. The problem is, however, that, strictly speaking, the results can be applied only to a person who has the same anatomy as the phantom, while for a person with different body mass and/or standing height the data could be wrong. In order to improve this situation for many areas in radiological protection, this study developed 18 anthropometric standing adult human phantoms, nine models per gender, as a function of the 10th, 50th and 90th mass and height percentiles of Caucasian populations. The anthropometric target parameters for body mass, standing height and other body measures were extracted from PeopleSize, a well-known software package used in the area of ergonomics. The phantoms were developed based on the assumption of a constant body-mass index for a given mass percentile and for different heights. For a given height, increase or decrease of body mass was considered to reflect mainly the change of subcutaneous adipose tissue mass, i.e. that organ masses were not changed. Organ mass scaling as a function of height was based on information extracted from autopsy data. The methods used here were compared with those used in other studies, anatomically as well as dosimetrically. For external exposure, the results show that equivalent dose decreases with increasing body mass for organs and tissues located below the subcutaneous adipose tissue layer, such as liver, colon, stomach, etc, while for organs located at the surface, such as breasts, testes and skin, the equivalent dose increases or remains constant with increasing body mass due to weak attenuation and more scatter radiation caused by the increasing adipose tissue mass. Changes of standing height have little influence on the equivalent dose to organs and tissues from external exposure. Specific absorbed fractions (SAFs) have also been calculated with the 18 anthropometric phantoms. The results show that SAFs decrease with increasing height and increase with increasing body mass. The calculated data suggest that changes of the body mass may have a significant effect on equivalent doses, primarily for external exposure to organs and tissue located below the adipose tissue layer, while for superficial organs, for changes of height and for internal exposures the effects on equivalent dose are small to moderate.
Haptoglobin Phenotype Among Arab Patients With Mental Disorders.
Armaly, Zaher; Farhat, Kamal; Kinaneh, Safa; Farah, Joseph
2018-03-01
Depression, schizophrenia and panic disorder are common mental disorders in the community and hospitalized patients. These mental disorders negatively affect life quality and even expectancy of life. Haptoglobin (Hp) phenotype (Hp 1-1, 1-2, or 2-2) is associated with risk for cardiovascular diseases, but its association with psychiatric disorders, a growing concern in the modern society, has not been studied thoroughly. The aim of the study was to examine whether Hp phenotype is associated with common mental disorders such as depression, schizophrenia, and panic disorder. The study included 92 Arab patients with mental disorders, and among them 44 suffered from schizophrenia (mean age 39 ± 1.5 years), 17 from depression (mean age 44.5 ± 3.1 years), 31 from panic disorder (mean age of 44.9 ± 2.7 years), and 206 healthy Arab control subjects with a mean age of 42.6 ± 0.9 years. Beck's depression inventory assessment and Hamilton depression scale were administered for depression and panic disorder diagnosis. Schizophrenia was evaluated with positive and negative affect schedule (Panas) test. All mental disorders were evaluated by clinical review. Blood analysis for Hp phenotype was performed. Diagnosis was made using the Diagnostic and Statistical Manual of Mental Disorders axis to correlate depression with Hp phenotype. In mentally healthy controls, 10.7% were Hp 1-1, 38.8% Hp 2-1, and 50.5% Hp 2-2. In patients with the studied psychiatric disorders, Hp phenotype was comparable to healthy subjects; 8.7% were Hp 1-1, 50% Hp 2-1, and 41.3% Hp 2-2. When Hp phenotyping was analyzed in the psychiatric subgroups, Hp 2-1 was more common among depressed and schizophrenic patients, as compared with healthy subjects (58.8% and 52.3% vs. 38.8%). In patients who suffer from panic disorder, Hp phenotype distribution was 6.5% Hp 1-1, 41.9% Hp 2-1, and 51.6% Hp 2-2, suggesting a lower prevalence among Hp 1-1 phenotype. Arab patients who carry Hp 2-1 phenotype may be at risk to develop depression or schizophrenia more than the general healthy population. In contrast, Hp 1-1 subjects have a lower prevalence of panic disorder.
Braga, Neilor Mateus Antunes; Souza-Gabriel, Aline Evangelista; Messias, Danielle Cristine Furtado; Rached-Junior, Fuad Jacob Abi; Oliveira, Camila Fávero; Silva, Ricardo Gariba; Silva-Sousa, Yara T Corrêa
2012-01-01
The aim of this study was to assess the influence of surface pretreatments of fiber-reinforced posts on flexural strength (FS), modulus of elasticity (ME) and morphology of these posts, as well as the bond strength (BS) between posts and core material. Fifty-two fiber posts (smooth and serrated) were assigned to 4 groups (n=13): no treatment (control), 10% hydrogen peroxide (HP) for 10 min (HP-10), 24% HP for 1 min (HP-24) and airborne-particle abrasion (Al(2)O(3)). To evaluate FS and ME, a 3-point bending test was performed. Three posts of each group were examined by scanning electron microscopy. Composite resin was used as the core build-up and samples were sectioned to obtain microtensile sticks. Data were analyzed by ANOVA and Tukey's test (α=0.05). For FS, significant differences were observed between posts type and surface pretreatment (p<0.05), with the highest means for the smooth posts. Al2O3 provided higher FS than HP-24. Al(2)O(3) promoted higher ME than HP-24 and control. SEM images revealed partial dissolution of the resin matrix in all treated groups. The smooth posts had higher BS and FS than serrated posts (p<0.05). Mechanical properties of the glass fiber posts and the bond strength between posts and composite material were not altered by the surface treatments, except for airborne-particle abrasion that increased the post elastic modulus.
2010-01-01
Background Porcine reproductive and respiratory syndrome virus (PRRSV) and Streptococcus suis are common pathogens in pigs. In samples collected during the porcine high fever syndrome (PHFS) outbreak in many parts of China, PRRSV and S. suis serotype 7 (SS7) have always been isolated together. To determine whether PRRSV-SS7 coinfection was the cause of the PHFS outbreak, we evaluated the pathogenicity of PRRSV and/or SS7 in a pig model of single and mixed infection. Results Respiratory disease, diarrhea, and anorexia were observed in all infected pigs. Signs of central nervous system (CNS) disease were observed in the highly pathogenic PRRSV (HP-PRRSV)-infected pigs (4/12) and the coinfected pigs (8/10); however, the symptoms of the coinfected pigs were clearly more severe than those of the HP-PRRSV-infected pigs. The mortality rate was significantly higher in the coinfected pigs (8/10) than in the HP-PRRSV- (2/12) and SS7-infected pigs (0/10). The deceased pigs of the coinfected group had symptoms typical of PHFS, such as high fever, anorexia, and red coloration of the ears and the body. The isolation rates of HP-PRRSV and SS7 were higher and the lesion severity was greater in the coinfected pigs than in monoinfected pigs. Conclusion HP-PRRSV infection increased susceptibility to SS7 infection, and coinfection of HP-PRRSV with SS7 significantly increased the pathogenicity of SS7 to pigs. PMID:20696031
Xu, Min; Wang, Shujie; Li, Linxi; Lei, Liancheng; Liu, Yonggang; Shi, Wenda; Wu, Jiabin; Li, Liqin; Rong, Fulong; Xu, Mingming; Sun, Guangli; Xiang, Hua; Cai, Xuehui
2010-08-09
Porcine reproductive and respiratory syndrome virus (PRRSV) and Streptococcus suis are common pathogens in pigs. In samples collected during the porcine high fever syndrome (PHFS) outbreak in many parts of China, PRRSV and S. suis serotype 7 (SS7) have always been isolated together. To determine whether PRRSV-SS7 coinfection was the cause of the PHFS outbreak, we evaluated the pathogenicity of PRRSV and/or SS7 in a pig model of single and mixed infection. Respiratory disease, diarrhea, and anorexia were observed in all infected pigs. Signs of central nervous system (CNS) disease were observed in the highly pathogenic PRRSV (HP-PRRSV)-infected pigs (4/12) and the coinfected pigs (8/10); however, the symptoms of the coinfected pigs were clearly more severe than those of the HP-PRRSV-infected pigs. The mortality rate was significantly higher in the coinfected pigs (8/10) than in the HP-PRRSV- (2/12) and SS7-infected pigs (0/10). The deceased pigs of the coinfected group had symptoms typical of PHFS, such as high fever, anorexia, and red coloration of the ears and the body. The isolation rates of HP-PRRSV and SS7 were higher and the lesion severity was greater in the coinfected pigs than in monoinfected pigs. HP-PRRSV infection increased susceptibility to SS7 infection, and coinfection of HP-PRRSV with SS7 significantly increased the pathogenicity of SS7 to pigs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Y; Kumar, P; Mitchell, M
Purpose: Breast cancer patients who undergo a mastectomy often require post-mastectomy radiation therapy (PMRT) due to high risk disease characteristics. PMRT usually accompanies scar boost irradiation (10–16Gy in 5–8 fractions) using en face electrons, which often results in increased dose to the underlying lungs, thereby potentially increasing the risk of radiation pneumonitis. Hence, this study evaluated water-equivalent phantoms as energy degraders and as an alternative to a bolus to reduce radiation dose to the underlying lungs for electron scar boost irradiation. Methods: Percent depth dose (PDD) profiles of 6 MeV (the lowest electron energy available in most clinics) were obtainedmore » without and with commercial solid water phantoms (1 to 5mm by 1mm increments) placed on top of electron cones. Phantom attenuation was measured by taking a ratio of outputs with to without the phantoms in 10×10cm2 cone size for monitor unit (MU) calculation. In addition, scatter dose to contralateral breast was measured on a human-like phantom using two selected scar (short and long) boost patient setups. Results: The PDD plots showed that the solid water phantoms and the bolus had similar dosimetric effects for the same thickness. Lower skin dose (up to 3%) to ipsilateral breast was observed with a 5mm phantom compared with a 5mm bolus (up to 10%) for all electron cones. Phantom attenuation was increased by 50% with about a 4.5mm phantom. Also, the energy degraders caused scatter dose to contralateral breast by a factor of 3 with a 5mm phantom. Conclusion: Our results demonstrate the feasibility of using water-equivalent phantoms to reduce lung dose using en face electrons in patients with a thin chest wall undergoing PMRT. The disadvantages of this treatment approach (i.e., the increase in MUs and treatment time, and clinically insignificant scatter dose to the contralateral breast given usually 10Gy) are outweighed by its above clinical benefits.« less
Development of a silicon diode detector for skin dosimetry in radiotherapy.
Vicoroski, Nikolina; Espinoza, Anthony; Duncan, Mitchell; Oborn, Bradley M; Carolan, Martin; Metcalfe, Peter; Menichelli, David; Perevertaylo, Vladimir L; Lerch, Michael L F; Rosenfeld, Anatoly B; Petasecca, Marco
2017-10-01
The aim of in vivo skin dosimetry was to measure the absorbed dose to the skin during radiotherapy, when treatment planning calculations cannot be relied on. It is of particularly importance in hypo-fractionated stereotactic modalities, where excessive dose can lead to severe skin toxicity. Currently, commercial diodes for such applications are with water equivalent depths ranging from 0.5 to 0.8 mm. In this study, we investigate a new detector for skin dosimetry based on a silicon epitaxial diode, referred to as the skin diode. The skin diode is manufactured on a thin epitaxial layer and packaged using the "drop-in" technology. It was characterized in terms of percentage depth dose, dose linearity, and dose rate dependence, and benchmarked against the Attix ionization chamber. The response of the skin diode in the build-up region of the percentage depth dose (PDD) curve of a 6 MV clinical photon beam was investigated. Geant4 radiation transport simulations were used to model the PDD in order to estimate the water equivalent measurement depth (WED) of the skin diode. Measured output factors using the skin diode were compared with the MOSkin detector and EBT3 film at 10 cm depth and at surface at isocenter of a water equivalent phantom. The intrinsic angular response of the skin diode was also quantified in charge particle equilibrium conditions (CPE) and at the surface of a solid water phantom. Finally, the radiation hardness of the skin diode up to an accumulated dose of 80 kGy using photons from a Co-60 gamma source was evaluated. The PDD curve measured with the skin diode was within 0.5% agreement of the equivalent Geant4 simulated curve. When placed at the phantom surface, the WED of the skin diode was estimated to be 0.075 ± 0.005 mm from Geant4 simulations and was confirmed using the response of a corrected Attix ionization chamber placed at water equivalent depth of 0.075 mm, with the measurement agreement to within 0.3%. The output factor measurements at 10 cm depth were within 2% of those measured with film and the MOSkin detector down to a field size of 2 × 2 cm 2 . The dose-response for all detector samples was linear and with a repeatability within 0.2%. The skin diode intrinsic angular response showed a maximum deviation of 8% at 90 degrees and from 0 to 60 degree is less than 5%. The radiation sensitivity reduced by 25% after an accumulated dose of 20 kGy but after was found to stabilize. At 60 kGy total accumulated dose the response was within 2% of that measured at 20 kGy total accumulated dose. This work characterizes an innovative detector for in vivo and real-time skin dose measurements that is based on an epitaxial silicon diode combined with the Centre for Medical Radiation Physics (CMRP) "drop-in" packaging technology. The skin diode proved to have a water equivalent depth of measurement of 0.075 ± 0.005 mm and the ability to measure doses accurately relative to reference detectors. © 2017 American Association of Physicists in Medicine.
What can blueschists tell about the Deep? High Pressure in the Anatolide - Taurid Belt
NASA Astrophysics Data System (ADS)
Oberhaensli, R.
2011-12-01
High-pressure metamorphic terranes in the Anatolide - Taurid belt document the complex distribution of paleo-sutures in the Tethyan realm. Field based petrologic studies of metapelites in the Anatolide-Taurid realm allow to trace HP-LT metamorphism not only in the well known ophiolitic Tavsanli Zone (2.4 GPa/500 °C) but also in the Afyon Zone (0.9 GPa/350 °C), the Menderes Massif (1.2 Gpa/500 °C;) and in the Lycian Nappes (1.0 Gpa/400 °C) - all situated north of the so called Taurid Platform. While the HP metamorphism is dated to 90-80 Ma (Rb/Sr; Ar/Ar) in the Tavsanli Zone, it ranges from 60-70 Ma (Ar/Ar) in the Afyon Zone and its tectonic equivalent, the Lycian Nappes. The Afyon Zone s.l. is closely related to the glaucophane- lawsonite-bearing rocks of the Tavsanli Zone and its eastward extension. Blueschist-facies metamorphism is documented by Fe,Mg-carpholite in regionally distributed metapelites and glaucophane in sparse mafic rocks (Afyon, Menderes, Lycia). Since observations of HP are based on Fe,Mg-carpholite bearing metasediments and not on mafic blueschists new thermodynamic data and petrologic modelling was elaborated to match P-T data and field-based observations. Moreover, newly formed phengitic mica allows precise dating. Both, Tavsanli and Afyon Zones can be followed along strike over more than 600 km and around the southern edge of the Central Anatolian Crystalline Complex. The two zones are situated north of the Taurid Platform and correlate with the Amasia Zone in Armenia. To the extreme East the Bitlis Complex underwent a LT - HP metamorphic blueschist evolution (1,1 GPa/ 350 °C; glaucophane, Fe,Mg-carpholite) in its sedimentary cover while the basement is eclogitic. Depending on the structural position and mineral association of phengitic mica metamorphic ages of the Bitlis blueschists scatter around 70-80 Ma. Eclogites from the basement are slightly older. These LT-HP units cannot be correlated with the Tavsanli - Afyon blueschist belts since they occur south of the Taurid Platform. Thus the Bitlis Complex represents a terrane detached from the Arabian Platform that subsequently collided with the Taurus Platform during closure of the Neo-Tethys. In SW Anatolia, south of the Taurus Platform, the Alanya Zone documents a Late Cretaceous HP evolution with blueschists and eclogites. Together with the Bitlis Complex the two Late Cretaceous HP-LT regions represent a suture south of the Taurid Platform but still north of the Hatay - Güleyman - Zagros ophiolites separating the Arabian Platform from the Anatolide-Taurid realm. The dissection of the Anatolide-Taurid realm into several paleo-subduction zones of Late Cretaceous age impacts on the lithospheric structure and has consequences for the Tertiary plateau formation in Central and Eastern Anatolia. Geophysical data and observations from the East Anatolian Plateau can be explained with petrologic modelling when hydration of the lithospheric lids above subduction zones is considered.
Lacroix, Fréderic; Archambault, Louis; Gingras, Luc; Guillot, Mathieu; Beddar, A Sam; Beaulieu, Luc
2008-08-01
A clinical prototype of a scintillating fiber dosimeter array for quality assurance applications is presented. The array consists of a linear array of 29 plastic scintillation detectors embedded in a water-equivalent plastic sheet coupled to optical fibers used to guide optical photons to a charge coupled device (CCD) camera. The CCD is packaged in a light-tight, radiation-shielded housing designed for convenient transport. A custom designed connector is used to ensure reproducible mechanical positioning of the optical fibers relative to the CCD. Profile and depth dose characterization measurements are presented and show that the prototype provides excellent dose measurement reproducibility (+/-0.8%) in-field and good accuracy (+/-1.6% maximum deviation) relative to the dose measured with an IC10 ionization chamber.
Poet, Torka; Hays, Sean
2017-10-13
1. Understanding species differences in the toxicokinetics of bisphenol A (BPA) is central to setting acceptable exposure limits for human exposures to BPA. BPA toxicokinetics have been well studied, with controlled oral dosing studies in several species and across a wide dose range. 2. We analyzed the available toxicokinetic data for BPA following oral dosing to assess potential species differences and dose dependencies. BPA is rapidly conjugated and detoxified in all species. The toxicokinetics of BPA can be well described using non-compartmental analyses. 3. Several studies measured free (unconjugated) BPA in blood and reported area under the curve (AUC) of free BPA in blood of mice, rats, monkeys, chimpanzees and humans following controlled oral doses. Extrinsic clearance was calculated and analyzed across species and dose using allometric scaling. 4. The results indicate free BPA clearance is well described using allometric scaling with high correlation coefficients across all species and doses up to 10 mg/kg. The results indicate a human equivalent dose factor (HEDf) of 0.9 is appropriate for extrapolating a point of departure from mice and rats to a human equivalent dose (HED), thereby replacing default uncertainty factors for animal to human toxicokinetics.
Measurements of the neutron spectrum in transit to Mars on the Mars Science Laboratory.
Köhler, J; Ehresmann, B; Zeitlin, C; Wimmer-Schweingruber, R F; Hassler, D M; Reitz, G; Brinza, D E; Appel, J; Böttcher, S; Böhm, E; Burmeister, S; Guo, J; Lohf, H; Martin, C; Posner, A; Rafkin, S
2015-04-01
The Mars Science Laboratory spacecraft, containing the Curiosity rover, was launched to Mars on 26 November 2011. Although designed for measuring the radiation on the surface of Mars, the Radiation Assessment Detector (RAD) measured the radiation environment inside the spacecraft during most of the 253-day, 560-million-kilometer cruise to Mars. An important factor for determining the biological impact of the radiation environment inside the spacecraft is the specific contribution of neutrons with their high biological effectiveness. We apply an inversion method (based on a maximum-likelihood estimation) to calculate the neutron and gamma spectra from the RAD neutral particle measurements. The measured neutron spectrum (12-436 MeV) translates into a radiation dose rate of 3.8±1.2 μGy/day and a dose equivalent of 19±5 μSv/day. Extrapolating the measured spectrum (0.1-1000 MeV), we find that the total neutron-induced dose rate is 6±2 μGy/day and the dose equivalent rate is 30±10 μSv/day. For a 360 day round-trip from Earth to Mars with comparable shielding, this translates into a neutron induced dose equivalent of about 11±4 mSv. Copyright © 2015 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
Auesomwang, Chonticha; Maneerattanaporn, Monthira; Chey, William D; Kiratisin, Pattarachai; Leelakusolwong, Somchai; Tanwandee, Tawesak
2018-05-27
Eradication rates of Helicobacter pylori following standard triple therapy are declining worldwide, but high-dose proton-pump inhibitor-based triple therapy (HD-PPI-TT) and sequential therapy (ST) have demonstrated higher cure rates. We aimed to compare the efficacy and tolerability of HD-PPI-TT and ST in H. pylori-associated functional dyspepsia (HP-FD). One hundred and twenty HP-FD patients were randomized to receive 10-day HD-PPI-TT (60 mg lansoprazole/500 mg clarithromycin/1 g amoxicillin, each administered twice daily for 10 days) or 10-day ST (30 mg lansoprazole/1 g amoxicillin, each administered twice daily for 5 days followed by 30 mg lansoprazole/500 mg clarithromycin/400 mg metronidazole, each administered twice daily for 5 days). H. pylori status was determined in post-treatment week 4 by 14 C-urea breath test. Eradication and antibiotic resistance rates, dyspeptic symptoms, drug compliance, and adverse effects were compared. Intention-to-treat (ITT) eradication rates were similar in the ST and HD-PPI-TT groups (85% vs. 80%; P=0.47). However, the eradication rate was significantly higher following ST compared with HD-PPI-TT in per protocol (PP) analysis (94.4% vs. 81.4%; P=0.035). ST achieved higher cure rates than HD-PPI-TT in clarithromycin-resistant H. pylori strains (100% vs. 33.3%; P=0.02). Treatment compliance was similar in the HD-PPI-TT and ST groups, although nausea and dizziness were more common in the ST group. ST achieved better H. pylori eradication than HD-PPI-TT in patients with FD. However, the eradication rate for ST fell from 94.4% in PP to 85% in ITT analysis. Adverse effects might result in poorer compliance and compromise actual ST efficacy. (ClinicalTrials.gov: NCT01888237). This article is protected by copyright. All rights reserved.
Künzler, Thomas; Fotina, Irina; Stock, Markus; Georg, Dietmar
2009-12-21
The dosimetric performance of a Monte Carlo algorithm as implemented in a commercial treatment planning system (iPlan, BrainLAB) was investigated. After commissioning and basic beam data tests in homogenous phantoms, a variety of single regular beams and clinical field arrangements were tested in heterogeneous conditions (conformal therapy, arc therapy and intensity-modulated radiotherapy including simultaneous integrated boosts). More specifically, a cork phantom containing a concave-shaped target was designed to challenge the Monte Carlo algorithm in more complex treatment cases. All test irradiations were performed on an Elekta linac providing 6, 10 and 18 MV photon beams. Absolute and relative dose measurements were performed with ion chambers and near tissue equivalent radiochromic films which were placed within a transverse plane of the cork phantom. For simple fields, a 1D gamma (gamma) procedure with a 2% dose difference and a 2 mm distance to agreement (DTA) was applied to depth dose curves, as well as to inplane and crossplane profiles. The average gamma value was 0.21 for all energies of simple test cases. For depth dose curves in asymmetric beams similar gamma results as for symmetric beams were obtained. Simple regular fields showed excellent absolute dosimetric agreement to measurement values with a dose difference of 0.1% +/- 0.9% (1 standard deviation) at the dose prescription point. A more detailed analysis at tissue interfaces revealed dose discrepancies of 2.9% for an 18 MV energy 10 x 10 cm(2) field at the first density interface from tissue to lung equivalent material. Small fields (2 x 2 cm(2)) have their largest discrepancy in the re-build-up at the second interface (from lung to tissue equivalent material), with a local dose difference of about 9% and a DTA of 1.1 mm for 18 MV. Conformal field arrangements, arc therapy, as well as IMRT beams and simultaneous integrated boosts were in good agreement with absolute dose measurements in the heterogeneous phantom. For the clinical test cases, the average dose discrepancy was 0.5% +/- 1.1%. Relative dose investigations of the transverse plane for clinical beam arrangements were performed with a 2D gamma-evaluation procedure. For 3% dose difference and 3 mm DTA criteria, the average value for gamma(>1) was 4.7% +/- 3.7%, the average gamma(1%) value was 1.19 +/- 0.16 and the mean 2D gamma-value was 0.44 +/- 0.07 in the heterogeneous phantom. The iPlan MC algorithm leads to accurate dosimetric results under clinical test conditions.
Ana, Monzó; Vicente, Montañana; María, Rubio José; Trinidad, García-Gimeno; Alberto, Romeu
2011-02-22
To compare the clinical results of four different protocols of COH for IVF-ICSI in normovulatory women, using in all cases pituitary suppression with GnRH antagonists. A single center, open label, parallel-controlled, prospective, post-authorization study under the approved conditions for use where 305 normal responders women who were candidates to COH were assigned to r-FSH +hp-hMG (n = 51, Group I), hp-hMG (n = 61, Group II), fixed-dose r-FSH (n = 118, Group III), and r-FSH with potential dose adjustment (n = 75, Group IV) to subsequently undergo IVF-ICSI. During stimulation, Group IV needed significantly more days of stimulation as compared to Group II [8.09 ± 1.25 vs. 7.62 ± 1.17; P < 0.05], but was the group in which more oocytes were recovered [Group I: 9.43 ± 4.99 vs. Group II: 8.96 ± 4.82 vs. Group III: 8.78 ± 3.72 vs. Group IV: 11.62 ± 5.80; P < 0.05]. No significant differences were seen between the groups in terms of clinical and ongoing pregnancy, but among patients in whom two embryos with similar quality parameters (ASEBIR) were transferred, the group treated with hp-hMG alone achieved a significantly greater clinical pregnancy rate as compared to all other groups [Group I: 31.6%, Group II: 56.4%, Group III: 28.7%, Group IV: 32.7%; P < 0.05]. Although randomized clinical trials should be conducted to achieve a more reliable conclusion, these observations support the concept that stimulation with hp-hMG could be beneficial in normal responders women undergoing pituitary suppression with GnRH antagonists.
Medina-Rosas, Jorge; Gladman, Dafna D; Su, Jiandong; Sabapathy, Arthy; Urowitz, Murray B; Touma, Zahi
2015-10-24
In this study, we determined: (1) the utility of an untimed sample of urine protein/creatinine ratio (PCR) as a screening test for proteinuria, (2) its ability to accurately measure proteinuria, and (3) cutoff values for PCR predicting protein content in a 24-h urine collection sample (24hP) of 0.5, 1.0, and 2.0 g/day. Analysis was performed on data from a single lupus cohort (2008-2014). Proteinuria was measured in a 24hP and with PCR. On the basis of 24hP, samples were divided into 4 groups: group 1, <0.5 g/day; group 2, 0.5-0.99 g/day; group 3, 1-1.99 g/day; and group 4, ≥2 g/day. To determine the validity of PCR in screening for proteinuria, the Pearson correlation coefficient was determined for the urine samples with normal PCR (<0.05 g/mmol) and normal 24hP (<0.5 g/day). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PCR were calculated. To determine the ability of PCR to accurately measure the level of proteinuria, in addition to the correlation between 24hP and PCR, agreement was determined by intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plot between 24hP/24hC and PCR. The best cutoffs for PCR predicting a 24hP of 0.5, 1.0, and 2.0 g/day were determined with the receiver operating characteristic curve. The correlation of the samples with normal PCR as well as 24hP (n = 552) was 0.29 (p < 0.0001). PCR sensitivity and specificity against 24hP were 91 % and 83 %, respectively. The PPV was 82.5 %, and the NPV was 91.4 %. The correlation for all samples (n = 1233) was high, but low to moderate for groups 1, 2, 3, and 4. The agreement for all samples was appropriate but poor for groups 1, 2, 3, and 4. PCR cutoffs for 24hP of 0.5, 1.0, and 2.0 g/day were 0.08, 0.16, and 0.35 g/mmol, respectively. PCR can be used as a screening test for proteinuria, and the best cutoff value to predict a 24hP of 0.5 g/day is 0.08 g/mmol (800 mg/g). The accurate level of proteinuria should be measured by the gold standard test, 24hP.
42 CFR 82.5 - Definition of terms used in this part.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Illness Compensation Program Act of 2000, 42 U.S.C. 7384-7385 [1994, supp. 2001]. (i) Equivalent dose is... equivalent dose that is received from radiation sources outside of the body. (k) Internal dose means that portion of the equivalent dose that is received from radioactive materials taken into the body. (l) NIOSH...
Efficacy of a type 2 PRRSV modified live vaccine (PrimePac™ PRRS) against a Thai HP-PRRSV challenge.
Sirisereewan, Chaitawat; Woonwong, Yonlayong; Arunorat, Jirapat; Kedkovid, Roongtham; Nedumpun, Teerawut; Kesdangsakonwut, Sawang; Suradhat, Sanipa; Thanawongnuwech, Roongroje; Teankum, Komkrich
2018-04-26
The Chinese highly pathogenic porcine reproductive and respiratory syndrome virus (HP-PRRSV) has caused a severe threat to the pig population in Southeast Asian countries. The purpose of this study was to investigate the efficacy of a type 2 PRRSV modified live vaccine (PrimePac™ PRRS, lineage 7) against a Thai HP-PRRSV (10PL01, lineage 8). Three-week-old PRRSV-free pigs were randomly assigned into three groups. Vaccinated challenged group (group 1, n = 16) was immunized with PrimePac™ PRRS vaccine at 3 weeks old. The unvaccinated challenged group (group 2, n = 16) was injected with PBS at 3 weeks old, and unvaccinated unchallenged group (group 3, n = 10) was served as a negative control. At 9 weeks old, all groups, except the negative control group, were challenged with the Thai HP-PRRSV. All pigs were monitored daily during 10 days post-infection (dpi) and were necropsied at 10 and 17 dpi. The results revealed that vaccinated challenged pigs showed significantly lower (p < 0.05) mean rectal temperatures, clinical respiratory scores, lung lesion scores, and levels of virus load in serum and lung tissue compared with the unvaccinated challenged pigs. Moreover, vaccinated challenged pigs exhibited PRRSV-specific serum neutralizing antibodies at the end of the experiment. Our findings indicated that the studied type 2 PRRSV vaccine provided partial protection against the Thai HP-PRRSV infection based on the body temperature, levels of viremia, and the severity of lung lesions. These results demonstrated that partial protection of PrimePac™ PRRS vaccine might be useful for controlling HP-PRRSV infection in the endemic area.
Wrzesień, Małgorzata
2018-05-22
A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium-99m (99mTc) and fluorine-18 (18F) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The 99mTc isotope is produced by a short-lived nuclide generator - molybdenum-99 (99Mo)/99mTc, while 18F is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the 99Mo/99mTc generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the 18F isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with 99Tc need to be verified. Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P - MCP-N) were used to determine the doses. Among the activities performed by employees of both 18F-fluorodeoxyglucose (18F-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with 99mTc isotope manifest the greatest contribution to the recorded Hp(0.07). The simplicity of obtaining the 99mTc isotope as well as the complex, but fully automated production process of the 18F-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with 99mTc or quality control of 18F-FDG. Med Pr 2018;69(3):317–327. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Reft, Chester S; Runkel-Muller, Renate; Myrianthopoulos, Leon
2006-10-01
For intensity modulated radiation therapy (IMRT) treatments 6 MV photons are typically used, however, for deep seated tumors in the pelvic region, higher photon energies are increasingly being employed. IMRT treatments require more monitor units (MU) to deliver the same dose as conformal treatments, causing increased secondary radiation to tissues outside the treated area from leakage and scatter, as well as a possible increase in the neutron dose from photon interactions in the machine head. Here we provide in vivo patient and phantom measurements of the secondary out-of-field photon radiation and the neutron dose equivalent for 18 MV IMRT treatments. The patients were treated for prostate cancer with 18 MV IMRT at institutions using different therapy machines and treatment planning systems. Phantom exposures at the different facilities were used to compare the secondary photon and neutron dose equivalent between typical IMRT delivered treatment plans with a six field three-dimensional conformal radiotherapy (3DCRT) plan. For the in vivo measurements LiF thermoluminescent detectors (TLDs) and Al2O3 detectors using optically stimulated radiation were used to obtain the photon dose and CR-39 track etch detectors were used to obtain the neutron dose equivalent. For the phantom measurements a Bonner sphere (25.4 cm diameter) containing two types of TLDs (TLD-600 and TLD-700) having different thermal neutron sensitivities were used to obtain the out-of-field neutron dose equivalent. Our results showed that for patients treated with 18 MV IMRT the photon dose equivalent is greater than the neutron dose equivalent measured outside the treatment field and the neutron dose equivalent normalized to the prescription dose varied from 2 to 6 mSv/Gy among the therapy machines. The Bonner sphere results showed that the ratio of neutron equivalent doses for the 18 MV IMRT and 3DCRT prostate treatments scaled as the ratio of delivered MUs. We also observed differences in the measured neutron dose equivalent among the three therapy machines for both the in vivo and phantom exposures.
Silva, Camilla V N S; Barbosa, Jéssica A P; Ferraz, Milena S; Silva, Nicácio H; Honda, Neli K; Rabello, Marcelo M; Hernandes, Marcelo Z; Bezerra, Beatriz P; Cavalcanti, Isabella M F; Ayala, Alejandro P; Santos, Noemia P S; Santos-Magalhães, Nereide S
2016-11-01
In this pioneer study, 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) was used to improve the solubility of the diffractaic acid (DA) via inclusion complex (DA:HP-β-CD). Subsequently, DA:HP-β-CD was incorporated into poly-ε-caprolactone (PCL) microspheres (DA:HP-β-CD-MS). Microspheres containing DA (DA-MS) or DA:HP-β-CD (DA:HP-β-CD-MS) were prepared using the multiple W/O/W emulsion-solvent evaporation technique. The phase-solubility diagram of DA in HP-β-CD (10-50mM) showed an A L type curve with a stability constant K 1:1 =821M -1 . 1 H NMR, FTIR, X-ray diffraction and thermal analysis showed changes in the molecular environment of DA in DA:HP-β-CD. The molecular modeling approach suggests a guest-host complex formation between the carboxylic moiety of both DA and the host (HP-β-CD). The mean particle size of the microspheres were ∅ DA-MS =5.23±1.65μm and ∅ DA:HP-β-CD-MS =4.11±1.39μm, respectively. The zeta potential values of the microspheres were ζ DA-MS =-7.85±0.32mV and ζ DA:HP-β-CD-MS =-6.93±0.46mV. Moreover, the encapsulation of DA:HP-β-CD into microspheres resulted in a more slower release (k 2 =0.042±0.001; r 2 =0.996) when compared with DA-MS (k 2 =0.183±0.005; r 2 =0.996). The encapsulation of DA or DA:HP-β-CD into microspheres reduced the cytotoxicity of DA (IC 50 =43.29μM) against Vero cells (IC 50 of DA-MS=108.48μM and IC 50 of DA:HP-β-CD-MS=142.63μM). Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cardenas, C; The University of Texas Graduate School of Biomedical Sciences, Houston, TX; Nitsch, P
Purpose: To investigate out-of-field electron doses and neutron production from electron beams from modern Varian and Elekta linear accelerators. Methods: Electron dose measurements were made using 10×10cm{sup 2} applicators on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at energies from 6 to 20 MeV. Out-of-field dose profiles and PDD curves were measured in a Wellhofer water phantom using a Farmer chamber. Neutron measurements were made with a combination of moderator buckets and gold activation-foils placed on the treatment couch at various locations in the patient plane on both the 21iX and Versa HD linear accelerators.more » Results: Electron doses were highest for the highest electron energies. Dose profile curves for the Varian units were found to be lower than those from the Versa HD unit, and were lower than photon beams. Elekta’s dose profiles were higher and exhibited a second dose peak around 20–30 cm from central-axis. Electron doses in this region (0.8–1.3% of dmax at central-axis) were close to 5 times (2.5–4.8) greater than doses from photon beams with similar energies. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. Q-values and neutron dose equivalent increased with energy and were typically higher on central-axis. 18 MV photon beam neutron dose equivalents were greater than any electron beam, being approximately 40 times greater than for the 20 MeV electron beam (21iX). Conclusion: The Versa HD exhibited higher than expected out-of-field electron doses in comparison to typical radiotherapy photon beams. Fortunately, out-of-field electron doses can be substantially reduced by applying a water-equivalent bolus with thickness of E(MeV)/4 in cm. Neutron contamination from clinical electron beams can be considered negligible in relation to photon beams but may need to be considered for special cases. This work was supported by Public Health Service Grant CA180803 awarded by the National Cancer Institute, United States Department of Health and Human Services.« less
Technical note: estimating absorbed doses to the thyroid in CT.
Huda, Walter; Magill, Dennise; Spampinato, Maria V
2011-06-01
To describe a method for estimating absorbed doses to the thyroid in patients undergoing neck CT examinations. Thyroid doses in anthropomorphic phantoms were obtained for all 23 scanner dosimetry data sets in the ImPACT CT patient dosimetry calculator. Values of relative thyroid dose [R(thy)(L)], defined as the thyroid dose for a given scan length (L) divided by the corresponding thyroid dose for a whole body scan, were determined for neck CT scans. Ratios of the maximum thyroid dose to the corresponding CTDI(vol) and [D'(thy)], were obtained for two phantom diameters. The mass-equivalent water cylinder of any patient can be derived from the neck cross-sectional area and the corresponding average Hounsfield Unit, and compared to the 16.5-cm diameter water cylinder that models the ImPACT anthropomorphic phantom neck. Published values of relative doses in water cylinders of varying diameter were used to adjust thyroid doses in the anthropomorphic phantom to those of any sized patient. Relative thyroid doses R(thy)(L) increase to unity with increasing scan length and with very small difference between scanners. A 10-cm scan centered on the thyroid would result in a dose that is, nearly 90% of the thyroid dose from a whole body scan when performed using the constant radiographic techniques. At 120 kV, the average value of D'(thy) for the 16-cm diameter was 1.17 +/- 0.05 and was independent of CT vendor and year of CT scanner, and choice of x-ray tube voltage. The corresponding average value of D'(thy) in the 32-cm diameter phantom was 2.28 +/- 0.22 and showed marked variations depending on vendor, year of introduction into clinical practice as well as x-ray tube voltage. At 120 kV, a neck equivalent to a 10-cm diameter cylinder of water would have thyroid doses 36% higher than those in the ImPACT phantom, whereas a neck equivalent to a 25-cm cylinder diameter would have thyroid doses 35% lower. Patient thyroid doses can be estimated by taking into account the amount of radiation used to perform the CT examination (CTDI(vol)) and accounting for scan length and patient anatomy (i.e., neck diameter) at the thyroid location.
Hostility, driving anger, and dangerous driving: the emerging role of hemispheric preference.
Gidron, Yori; Gaygısız, Esma; Lajunen, Timo
2014-12-01
Various studies have implicated psychosocial variables (e.g., hostility) in risk of dangerous driving and traffic accidents. However, whether these variables are related to more basic neurobiological factors, and whether such associations have implications for the modification of psychosocial risk factors in the context of driving, have not been examined in depth. This study examined the relationship between hemispheric preference (HP), hostility and self-reported dangerous driving, and the ability to affect driving anger via hemisphere activating cognitive exercises (HACE). In Study 1, 254 Turkish students completed questionnaires of hostility, HP and driving behavior. In Study 2, we conducted a "proof of concept" experimental study, and tested effects of left, right and neutral HACE on driving anger, by exposing N=650 Turkish students to written scenarios including either logical (left hemisphere), visuo-spatial (right hemisphere) or "mild doses" of both types of contents (control). In Study 1, left-HP was associated with higher hostility and with more dangerous driving, and hostility mediated the relationship between L-HP and reported driving behavior. In Study 2, only right-HACE led to immediate significant reductions in self-reported driving anger. Left-HP is related to hostility and to dangerous driving, and it may be possible to partly reduce driving anger by right-HACE. Future studies must replicate these findings with objective measures, more enduring interventions and longer follow-ups. Copyright © 2014. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, W.F.; Molteni, A.; Ts'ao, C.H.
The purpose of this study was to evaluate the angiotensin converting enzyme (ACE) inhibitor CL242817 as a modifier of radiation-induced pulmonary endothelial dysfunction and pulmonary fibrosis in rats sacrificed 2 months after a single dose of 60Co gamma rays (0-30 Gy) to the right hemithorax. CL242817 was administered in the feed continuously after irradiation at a regimen of 60 mg/kg/day. Pulmonary endothelial function was monitored by lung ACE activity, plasminogen activator (PLA) activity, and prostacyclin (PGI2) and thromboxane (TXA2) production. Pulmonary fibrosis was evaluated by lung hydroxyproline (HP) content. Lung ACE and PLA activities decreased with increasing radiation dose, andmore » cotreatment with CL242817 significantly ameliorated both responses. CL242817 dose-reduction factors (DRF) were 1.3-1.5 for ACE and PLA activity. Lung PGI2 and TXA2 production increased with increasing radiation dose, and CL242817 almost completely prevented both radiation responses. The slope of the radiation dose-response curves in the CL242817-treated rats was essentially zero, precluding calculation of DRF values for PGI2 and TXA2 production. Lung HP content also increased with increasing radiation dose, and CL242817 significantly attenuated this response (DRF = 1.5). These data suggest that the ability of ACE inhibitors to ameliorate radiation-induced pulmonary endothelial dysfunction is not unique to captopril, rather it is a therapeutic action shared by other members of this class of compounds. These data also provide the first evidence that ACE inhibitors exhibit antifibrotic activity in irradiated rat lung.« less
Ouyang, Wen; Tchida, Colin
2017-05-02
Static torque, no load, constant speed, and sinusoidal oscillation test data for a 10hp, 300rpm magnetically-geared generator prototype using either an adjustable load bank for a fixed resistance or an output power converter.
Body indices and basic vital signs in Helicobacter pylori positive and negative persons.
Kopácová, Marcela; Bures, Jan; Koupil, Ilona; Rejchrt, Stanislav; Vorísek, Viktor; Seifert, Bohumil; Pozler, Oldrich; Zivný, Pavel; Douda, Tomás; Palicka, Vladimír; Holcík, Jan
2007-01-01
It has been hypothesized that Helicobacter pylori (Hp) infection may contribute to reduced stature, risk of hypertension or obesity. The aim was to evaluate body indices in Hp positive and negative persons. A total of 2436 subjects (4-100 years old) were tested for Hp status by (13)C-urea breath test. Data on height and weight were collected for 84%, and blood pressure for 80% of the study subjects. The prevalence of Hp infection was 41.6%. The odds ratio for a 10-year increase in age was 1.21 (95% CI 1.17-1.25, p-value <0.001). Statistically significant negative association of Hp positivity with body height was most pronounced in the younger age groups, while a positive association of Hp positivity with body mass index was only seen in those aged 15+ years. There was a negative effect of Hp positivity on systolic and diastolic blood pressure in subjects below 25 and a relatively strong positive effect on blood pressure in subjects over 65 years. Residual confounding by social characteristics as a possible explanation for the associations of Hp positivity with height and blood pressure cannot be excluded. Unmeasured factors related to social and family environment may cause the apparent association between Hp positivity and children's growth and blood pressure.
Dose Equivalents for Second-Generation Antipsychotic Drugs: The Classical Mean Dose Method
Leucht, Stefan; Samara, Myrto; Heres, Stephan; Patel, Maxine X.; Furukawa, Toshi; Cipriani, Andrea; Geddes, John; Davis, John M.
2015-01-01
Background: The concept of dose equivalence is important for many purposes. The classical approach published by Davis in 1974 subsequently dominated textbooks for several decades. It was based on the assumption that the mean doses found in flexible-dose trials reflect the average optimum dose which can be used for the calculation of dose equivalence. We are the first to apply the method to second-generation antipsychotics. Methods: We searched for randomized, double-blind, flexible-dose trials in acutely ill patients with schizophrenia that examined 13 oral second-generation antipsychotics, haloperidol, and chlorpromazine (last search June 2014). We calculated the mean doses of each drug weighted by sample size and divided them by the weighted mean olanzapine dose to obtain olanzapine equivalents. Results: We included 75 studies with 16 555 participants. The doses equivalent to 1 mg/d olanzapine were: amisulpride 38.3 mg/d, aripiprazole 1.4 mg/d, asenapine 0.9 mg/d, chlorpromazine 38.9 mg/d, clozapine 30.6 mg/d, haloperidol 0.7 mg/d, quetiapine 32.3mg/d, risperidone 0.4mg/d, sertindole 1.1 mg/d, ziprasidone 7.9 mg/d, zotepine 13.2 mg/d. For iloperidone, lurasidone, and paliperidone no data were available. Conclusions: The classical mean dose method is not reliant on the limited availability of fixed-dose data at the lower end of the effective dose range, which is the major limitation of “minimum effective dose methods” and “dose-response curve methods.” In contrast, the mean doses found by the current approach may have in part depended on the dose ranges chosen for the original trials. Ultimate conclusions on dose equivalence of antipsychotics will need to be based on a review of various methods. PMID:25841041
Cao, Yi-Juan; Li, Zhen-Bei; Qi, Yu-Juan; Liu, Ying; Gu, Juan; Hu, Fang-Fang; Zhang, Wen-da; Hao, Lin; Hou, Jian-Quan; Han, Cong-Hui
2016-12-01
To investigate the effects of cynomorium songaricum (CS) decoction on the testis weight, serum testosterone level, and sperm parameters of rats with oligoasthenospermia (OAS), explore its action mechanism of improving the proliferation of undifferentiated spermatogonial cells, and provide some experimental and theoretical evidence for the development of new Chinese drugs for OAS. Thirty 8-week-old male SD rats were randomly divided into five groups of equal number: blank control, model control, high-dose CS, medium-dose CS, and low-dose CS. OAS models were established by intraperitoneal injection of cyclophosphamide and, a month later, treated intragastrically with normal saline or CS at 2, 1, and 0.5 g per kg of the body weight per day, all for 4 weeks. Then, the testes of the animals were harvested to obtain the testicular weight, sperm concentration and motility, and the level of serum testosterone (T), detect the expressions of the transcription factor 1 (Oct4), Thy-1 cell surface antigen (Thy1), promyelocytic leukemia zinc finger (PLZF), KIT proto-oncogene receptor tyrosine kinase (C-kit) and glial cell-derived neurotrophic factor (GDNF) in the testis tissue of the rats in the low-dose CS group by real-time PCR. The testis weights in the blank control, model control, high-dose CS, medium-dose CS, and low-dose CS groups were (1.52±0.06), (1.55±0.06), (1.43±0.30), (1.35±0.40) and (1.34±0.04) g, respectively, not significantly different in the blank and model controls from those in the CS groups (P>0.05). The visual field sperm count per 10 HP was significantly increased in the high-, medium-, and low-dose CS groups (202±20, 196±5 and 216±25) as compared with the blank and model controls (200±15 and 134±30) (P<0.05). The mRNA expressions of the Oct4, Thy1, PLZF and GDNF genes were remarkably higher in the low-dose CS group than in the controls (P<0.05), but that of the C-kit gene showed no significant difference from the latter (P>0.05). The visual field sperm motility per 10 HP was markedly increased in the blank control ([52.1±5.5]%), model control ([38.1±2.5]%), high-dose CS ([59.1±9.5]%), medium-dose CS ([58.7±9.5]%), and low-dose CS ([49.6±1.0]%) groups, and so was the level of serum testosterone ([190±87.5], [82.5±25.8], [229±75.6], [331±86.7] and [185±82.4] mmol/L), both remarkably higher in the CS groups than in the model controls (P<0.05) but with no statistically significant difference between the CS groups and the blank controls (P>0.05). CS can significantly improve sperm concentration, sperm motility and serum T level in OAS rats, probably by inducing the expression of GDNF in the rat Sertoli cells, promoting the proliferation of undifferentiated spermatogonial cells, and enhancing spermatogenesis.
Lucero, Yalda; Oyarzún, Amaya; O'Ryan, Miguel; Quera, Rodrigo; Espinosa, Nelly; Valenzuela, Romina; Simian, Daniela; Alcalde, Elisa; Arce, Claudio; Farfán, Mauricio J; Vergara, Alejandra F; Gajardo, Iván; Mendez, Jocelyn; Carrasco, Jorge; Errázuriz, Germán; Gonzalez, Mónica; Ossa, Juan C; Maiza, Eduardo; Perez-Bravo, Francisco; Castro, Magdalena; Araya, Magdalena
2017-01-01
HIGHLIGHTS What is already known about this subject?Celiac disease (CD) has a high clinical and histological diversity and the mechanisms underlying this phenomenon remain elusive. H. pylori is a bacterium that chronically infect gastric and duodenal mucosa activating both a Th1/Th17 and T-reg pathways.The role of H. pylori (and the effect of their virulence factors) in CD have not yet completely elucidated.What are the new findings? cagA + H. pylori strains are associated to milder histological damage in infected CD patients.In active-CD patients the presence of cagA + H. pylori is associated to an increase in T-reg markers, contrasting with a downregulation in cagA + infected potential-CD individuals.How might it impact on clinical practice in the foreseeable future?The identification of microbiological factors that could modulate inflammation and clinical expression of CD may be used in the future as preventive strategies or as supplementary treatment in patients that cannot achieve complete remission, contributing to the better care of these patients. Background: Mechanisms underlying the high clinical and histological diversity of celiac disease (CD) remain elusive. Helicobacter pylori (Hp) chronically infects gastric and duodenal mucosa and has been associated with protection against some immune-mediated conditions, but its role (specifically of cagA + strains) in CD is unclear. Objective: To assess the relationship between gastric Hp infection ( cagA + strains) and duodenal histological damage in patients with CD. Design: Case-control study including patients with active-CD, potential-CD and non-celiac individuals. Clinical presentation, HLA genotype, Hp/ cagA gene detection in gastric mucosa, duodenal histology, Foxp3 positive cells and TGF-β expression in duodenal lamina propria were analyzed. Results: We recruited 116 patients, 29 active-CD, 37 potential-CD, and 50 non-CD controls. Hp detection was similar in the three groups (~30-40%), but cagA + strains were more common in infected potential-CD than in active-CD (10/11 vs. 4/10; p = 0.020) and non-CD (10/20; p = 0.025). Among active-CD patients, Foxp3 positivity was significantly higher in subjects with cagA + Hp+ compared to cagA- Hp+ ( p < 0.01) and Hp- ( p < 0.01). In cagA+ Hp+ individuals, Foxp3 positivity was also higher comparing active- to potential-CD ( p < 0.01). TGF-β expression in duodenum was similar in active-CD with cagA + Hp+ compared to Hp- and was significantly downregulated in cagA + potential-CD subjects compared to other groups. Conclusion: Hp infection rates were similar among individuals with/without CD, but infection with cagA + strains was associated with milder histological damage in celiac patients infected by Hp, and in active-CD cases with higher expression of T-reg markers. Results suggest that infection by cagA + Hp may be protective for CD progression, or conversely, that these strains are prone to colonize intestinal mucosa with less severe damage.
Maragos, Stratos; Archontaki, Helen; Macheras, Panos; Valsami, Georgia
2009-01-01
Praziquantel (PZQ), the primary drug of choice in the treatment of schistosomiasis, is a highly lipophilic drug that possesses high permeability and low aqueous solubility and is, therefore, classified as a Class II drug according to the Biopharmaceutics Classification System (BCS). In this work, beta-cyclodextrin (beta-CD) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) were used in order to determine whether increasing the aqueous solubility of a drug by complexation with CDs, a BCS-Class II compound like PZQ could behave as BCS-Class I (highly soluble/highly permeable) drug. Phase solubility and the kneading and lyophilization techniques were used for inclusion complex preparation; solubility was determined by UV spectroscopy. The ability of the water soluble polymer polyvinylpyrolidone (PVP) to increase the complexation and solubilization efficiency of beta-CD and HP-beta-CD for PZQ was examined. Results showed significant improvement of PZQ solubility in the presence of both cyclodextrins but no additional effect in the presence of PVP. The solubility/dose ratios values of PZQ-cyclodextrin complexes calculated considering the low (150 mg) and the high dose (600 mg) of PZQ, used in practice, indicate that PZQ complexation with CDs may result in drug dosage forms that would behave as a BCS-Class I depending on the administered dose.
ORANGE: a Monte Carlo dose engine for radiotherapy.
van der Zee, W; Hogenbirk, A; van der Marck, S C
2005-02-21
This study presents data for the verification of ORANGE, a fast MCNP-based dose engine for radiotherapy treatment planning. In order to verify the new algorithm, it has been benchmarked against DOSXYZ and against measurements. For the benchmarking, first calculations have been done using the ICCR-XIII benchmark. Next, calculations have been done with DOSXYZ and ORANGE in five different phantoms (one homogeneous, two with bone equivalent inserts and two with lung equivalent inserts). The calculations have been done with two mono-energetic photon beams (2 MeV and 6 MeV) and two mono-energetic electron beams (10 MeV and 20 MeV). Comparison of the calculated data (from DOSXYZ and ORANGE) against measurements was possible for a realistic 10 MV photon beam and a realistic 15 MeV electron beam in a homogeneous phantom only. For the comparison of the calculated dose distributions and dose distributions against measurements, the concept of the confidence limit (CL) has been used. This concept reduces the difference between two data sets to a single number, which gives the deviation for 90% of the dose distributions. Using this concept, it was found that ORANGE was always within the statistical bandwidth with DOSXYZ and the measurements. The ICCR-XIII benchmark showed that ORANGE is seven times faster than DOSXYZ, a result comparable with other accelerated Monte Carlo dose systems when no variance reduction is used. As shown for XVMC, using variance reduction techniques has the potential for further acceleration. Using modern computer hardware, this brings the total calculation time for a dose distribution with 1.5% (statistical) accuracy within the clinical range (less then 10 min). This means that ORANGE can be a candidate for a dose engine in radiotherapy treatment planning.
Beck, P; Latocha, M; Dorman, L; Pelliccioni, M; Rollet, S
2007-01-01
As required by the European Directive 96/29/Euratom, radiation exposure due to natural ionizing radiation has to be taken into account at workplaces if the effective dose could become more than 1 mSv per year. An example of workers concerned by this directive is aircraft crew due to cosmic radiation exposure in the atmosphere. Extensive measurement campaigns on board aircrafts have been carried out to assess ambient dose equivalent. A consortium of European dosimetry institutes within EURADOS WG5 summarized experimental data and results of calculations, together with detailed descriptions of the methods for measurements and calculations. The radiation protection quantity of interest is the effective dose, E (ISO). The comparison of results by measurements and calculations is done in terms of the operational quantity ambient dose equivalent, H(10). This paper gives an overview of the EURADOS Aircraft Crew In-Flight Database and it presents a new empirical model describing fitting functions for this data. Furthermore, it describes numerical simulations performed with the Monte Carlo code FLUKA-2005 using an updated version of the cosmic radiation primary spectra. The ratio between ambient dose equivalent and effective dose at commercial flight altitudes, calculated with FLUKA-2005, is discussed. Finally, it presents the aviation dosimetry model AVIDOS based on FLUKA-2005 simulations for routine dose assessment. The code has been developed by Austrian Research Centers (ARC) for the public usage (http://avidos.healthphysics.at).
Galactic and solar radiation exposure to aircrew during a solar cycle.
Lewis, B J; Bennett, L G I; Green, A R; McCall, M J; Ellaschuk, B; Butler, A; Pierre, M
2002-01-01
An on-going investigation using a tissue-equivalent proportional counter (TEPC) has been carried out to measure the ambient dose equivalent rate of the cosmic radiation exposure of aircrew during a solar cycle. A semi-empirical model has been derived from these data to allow for the interpolation of the dose rate for any global position. The model has been extended to an altitude of up to 32 km with further measurements made on board aircraft and several balloon flights. The effects of changing solar modulation during the solar cycle are characterised by correlating the dose rate data to different solar potential models. Through integration of the dose-rate function over a great circle flight path or between given waypoints, a Predictive Code for Aircrew Radiation Exposure (PCAIRE) has been further developed for estimation of the route dose from galactic cosmic radiation exposure. This estimate is provided in units of ambient dose equivalent as well as effective dose, based on E/H x (10) scaling functions as determined from transport code calculations with LUIN and FLUKA. This experimentally based treatment has also been compared with the CARI-6 and EPCARD codes that are derived solely from theoretical transport calculations. Using TEPC measurements taken aboard the International Space Station, ground based neutron monitoring, GOES satellite data and transport code analysis, an empirical model has been further proposed for estimation of aircrew exposure during solar particle events. This model has been compared to results obtained during recent solar flare events.
Changes in ambient dose equivalent rates around roads at Kawamata town after the Fukushima accident.
Kinase, Sakae; Sato, Satoshi; Sakamoto, Ryuichi; Yamamoto, Hideaki; Saito, Kimiaki
2015-11-01
Changes in ambient dose equivalent rates noted through vehicle-borne surveys have elucidated ecological half-lives of radioactive caesium in the environment. To confirm that the ecological half-lives are appropriate for predicting ambient dose equivalent rates within living areas, it is important to ascertain ambient dose equivalent rates on/around roads. In this study, radiation monitoring on/around roads at Kawamata town, located about 37 km northwest of the Fukushima Daiichi Nuclear Power Plant, was performed using monitoring vehicles and survey meters. It was found that the ambient dose equivalent rates around roads were higher than those on roads as of October 2012. And withal the ecological half-lives on roads were essentially consistent with those around roads. With dose predictions using ecological half-lives on roads, it is necessary to make corrections to ambient dose equivalent rates through the vehicle-borne surveys against those within living areas. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Code of Federal Regulations, 2011 CFR
2011-07-01
....102 Standard. (a) Emissions of radionuclides, including iodine, to the ambient air from a facility... receive in any year an effective dose equivalent of 10 mrem/yr. (b) Emissions of iodine to the ambient air...
Code of Federal Regulations, 2010 CFR
2010-07-01
....102 Standard. (a) Emissions of radionuclides, including iodine, to the ambient air from a facility... receive in any year an effective dose equivalent of 10 mrem/yr. (b) Emissions of iodine to the ambient air...
Large-Scale, Long-Lived Subduction of Ultrahigh-Pressure Terranes: Western Gneiss Region, Norway
NASA Astrophysics Data System (ADS)
Kylander-Clark, A. R.; Hacker, B. R.; Johnson, C. M.; Beard, B. L.; Corfu, F.; Mahlen, N. J.
2007-12-01
Recent Lu-Hf and Sm-Nd ages of garnets and a U-Pb age of zircon of eclogites from the Western Gneiss Region (WGR) ultrahigh-pressure (UHP) terrane, Norway, demonstrate that eclogite-facies metamorphism occurred over a large area (60,000 km2) for an unexpectedly long time. This observation stands in stark contrast to the general belief that continental subduction, and attendant (U)HP metamorphism, occurs over short timescales. Four HP eclogites (~700-800°C, ~2.0-2.5 GPa) from the central WGR yielded equivalent Lu-Hf ages of ~416 Ma; three of these samples gave Sm-Nd ages of ~400 Ma. Given the distribution coefficients for Lu and Sm, the older Lu-Hf ages reflect prograde growth, but are younger than the initiation of garnet crystallization. The younger Sm-Nd ages represent either eclogite-facies cooling through the blocking temperature of the Sm-Nd system or an 'average' age of garnet growth. Both cases imply >16 m.y. of eclogite- facies conditions. Two UHP eclogites (~750-850°C, ~3 GPa) from the same region yielded significantly younger, but equivalent Lu-Hf and Sm-Nd ages of ~380 Ma, which likely indicate passage through the blocking temperature of both systems up to 20 m.y. after the HP eclogites had passed through the blocking temperature. Because these eclogites are unretrogressed, their ages are the youngest known for eclogite stability in the WGR. An eclogite from the northern WGR yielded a Sm-Nd age of 413.9 ± 3.7 Ma. This could represent a different HP history than that of the central WGR: U/Pb ages in the north are also ~15 m.y. older. Two HP (~650°C, ~2 GPa) eclogites from the southern WGR yielded Lu-Hf ages of 410.2 ± 3.1 and 427.5 ± 7.7 Ma, indicating a similar garnet growth history to the central WGR eclogites. A retrogressed eclogite from the undated eastern portion of the WGR gave a 206Pb/238U age of 408.0 ± 1.7 Ma. Thermal models mirror results from similar studies (Roselle et al., 2002), and confirm that slow subduction likely produced the P-T-t record observed in the WGR. For subduction of a continent into a formerly Andean-style subduction zone, Calculated temperatures of ~700-800°C are reached at 100 km depth only at burial rates slower than 4 mm/yr. These same temperatures are achieved with slow burial (4-7 mm/yr) during intracontinental subduction.
Equivalent Noise Dose Obtained through Hearing Aids in the Classrooms of Hearing-Impaired Children.
ERIC Educational Resources Information Center
Wilde, Ronald A.
1990-01-01
A commercial noise dose meter was used to estimate the equivalent noise dose received through high-gain hearing aids worn in four classrooms in a school for deaf children. There were no significant differences among nominal saturation sound pressure level (SSPL) settings, and all SSPL settings produced very high equivalent noise doses. (Author/JDD)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Q; Shanghai General Hospital, Shanghai, Shanghai; Zhuo, W
Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominalmore » antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)« less
Effective Dose Equivalent due to Cosmic Ray Particles and Their Secondary Particles on the Moon
NASA Astrophysics Data System (ADS)
Hayatsu, Kanako; Hareyama, Makoto; Kobayashi, Shingo; Karouji, Yuzuru; Sakurai, K.; Sihver, Lembit; Hasebe, N.
Estimation of radiation dose on and under the lunar surface is quite important for human activity on the Moon and for the future lunar bases construction. Radiation environment on the Moon is much different from that on the Earth. Galactic cosmic rays (GCRs) and solar energetic particles (SEPs) directly penetrate the lunar surface because of no atmosphere and no magnetic field around the Moon. Then, they generate many secondary particles such as neutrons, gamma rays and other charged particles by nuclear interactions with soils and regolith breccias under the lunar surface. Therefore, the estimation of radiation dose from them on the surface and the underground of the Moon are essential for safety human activities. In this study, the effective dose equivalents at the surface and various depths of the Moon were estimated using by the latest cosmic rays observation and developed calculation code. The largest contribution to the dose on the surface is primary charged particles in GCRs and SEPs, while in the ground, secondary neutrons are the most dominant. In particular, the dose from neutrons becomes maximal at 70-80 g/cm2 in depth of lunar soil, because fast neutrons with about 1.0 MeV are mostly produced at this depth and give the largest dose. On the lunar surface, the doses originated from large SEPs are very hazardous. We estimated the effective dose equivalents due to such large SEPs and the effects of aluminum shield for the large flare on the human body. In the presentation, we summarize and discuss the improved calculation results of radiation doses due to GCR particles and their secondary particles in the lunar subsurface. These results will provide useful data for the future exploration of the Moon.
NASA Astrophysics Data System (ADS)
Cao, Zhong; Miller, L. F.; Buckner, M.
In order to accurately determine dose equivalent in radiation fields that include both neutrons and photons, it is necessary to measure the relative number of neutrons to photons and to characterize the energy dependence of the neutrons. The relationship between dose and dose equivalent begins to increase rapidly at about 100 keV; thus, it is necessary to separate neutrons from photons for neutron energies as low as about 100 keV in order to measure dose equivalent in a mixed radiation field that includes both neutrons and photons. Preceptron and back propagation neural networks that use pulse amplitude and pulse rise time information obtain separation of neutron and photons with about 5% error for neutrons with energies as low as 100 keV, and this is accomplished for neutrons with energies that range from 100 keV to several MeV. If the ratio of neutrons to photons is changed by a factor of 10, the classification error increases to about 15% for the neural networks tested. A technique that uses the output from the preceptron as a priori for a Bayesian classifier is more robust to changes in the relative number of neutrons to photons, and it obtains a 5% classification error when this ratio is changed by a factor of ten. Results from this research demonstrate that it is feasible to use commercially available instrumentation in combination with artificial intelligence techniques to develop a practical detector that will accurately measure dose equivalent in mixed neutron-photon radiation fields.
Steward, Andrew J; Kelly, Daniel J; Wagner, Diane R
2016-06-01
Although hydrostatic pressure (HP) is known to regulate chondrogenic differentiation of mesenchymal stromal/stem cells (MSCs), improved insight into the mechanotransduction of HP may form the basis for novel tissue engineering strategies. Previously, we demonstrated that matrix stiffness and calcium ion (Ca(++)) mobility regulate the mechanotransduction of HP; however, the mechanisms, by which these Ca(++) signaling pathways are initiated, are currently unknown. The purinergic pathway, in which adenosine triphosphate (ATP) is released and activates P-receptors to initiate Ca(++) signaling, plays a key role in the mechanotransduction of compression, but has yet to be investigated with regard to HP. Therefore, the objective of this study was to investigate the interplay between purinergic signaling, matrix stiffness, and the chondrogenic response of MSCs to HP. Porcine bone marrow-derived MSCs were seeded into soft or stiff agarose hydrogels and subjected to HP (10 MPa at 1 Hz for 4 h/d for 21 days) or kept in free swelling conditions. Stiff constructs were incubated with pharmacological inhibitors of extracellular ATP, P2 receptors, or hemichannels, or without any inhibitors as a control. As with other loading modalities, HP significantly increased ATP release in the control group; however, inhibition of hemichannels completely abrogated this response. The increase in sulfated glycosaminoglycan (sGAG) synthesis and vimentin reorganization observed in the control group in response to HP was suppressed in the presence of all three inhibitors, suggesting that purinergic signaling is involved in the mechanoresponse of MSCs to HP. Interestingly, ATP was released from both soft and stiff hydrogels in response to HP, but HP only enhanced chondrogenesis in the stiff hydrogels, indicating that matrix stiffness may act downstream of purinergic signaling to regulate the mechanoresponse of MSCs to HP. Addition of exogenous ATP did not replicate the effects of HP on chondrogenesis, suggesting that mechanisms other than purinergic signaling also regulate the response of MSCs to HP.
Aurora-B/AIM-1 Regulates the Dynamic Behavior of HP1α at the G2–M Transition
2006-01-01
Heterochromatin protein 1 (HP1) plays an important role in heterochromatin formation and undergoes large-scale, progressive dissociation from heterochromatin in prophase cells. However, the mechanisms regulating the dynamic behavior of HP1 are poorly understood. In this study, the role of Aurora-B was investigated with respect to the dynamic behavior of HP1α. Mammalian Aurora-B, AIM-1, colocalizes with HP1α to the heterochromatin in G2. Depletion of Aurora-B/AIM-1 inhibited dissociation of HP1α from the chromosome arms at the G2–M transition. In addition, depletion of INCENP led to aberrant cellular localization of Aurora-B/AIM-1, but it did not affect heterochromatin targeting of HP1α. It was proposed in the binary switch hypothesis that phosphorylation of histone H3 at Ser-10 negatively regulates the binding of HP1α to the adjacent methylated Lys-9. However, Aurora-B/AIM-1-mediated phosphorylation of H3 induced dissociation of the HP1α chromodomain but not of the intact protein in vitro, indicating that the center and/or C-terminal domain of HP1α interferes with the effect of H3 phosphorylation on HP1α dissociation. Interestingly, Lys-9 methyltransferase SUV39H1 is abnormally localized together along the metaphase chromosome arms in Aurora-B/AIM-1–depleted cells. In conclusion, these results showed that Aurora-B/AIM-1 is necessary for regulated histone modifications involved in binding of HP1α by the N terminus of histone H3 during mitosis. PMID:16687578
Llena, Carmen; Esteve, Irene; Forner, Leopoldo
2017-07-01
The aim of the study was to evaluate the bleaching effect, morphological changes, and variations in calcium (Ca) and phosphate (P) in the enamel with hydrogen peroxide (HP) and carbamide peroxide (CP) after the use of different application regimens. Four groups of five teeth were randomly assigned, according to the treatment protocol: HP 37.5% applied for 30 or 60 minutes (HP30, HP60), CP 16% applied for 14 or 28 hours (CP14, CP28). Changes in dental color were evaluated, according to the following formula: ΔE = [(L a -L b ) 2 +(a a -a b ) 2 + (b a -b b ) 2 ] 1/2 . Enamel morphology and Ca and P compositions were evaluated by confocal laser scanning microscope and environmental scanning electron microscopy. ΔE HP30 was significantly greater than CP14 (10.37 ± 2.65/8.56 ± 1.40), but not between HP60 and CP28. HP60 shows greater morphological changes than HP30. No morphological changes were observed in the groups treated with CP. The reduction in Ca and P was significantly greater in HP60 than in CP28 (p < 0.05). Both formulations improved tooth color; HP produced morphological changes and Ca and P a gradual decrease, while CP produced no morphological changes, and the decrease in mineral component was smaller. CP 16% applied during 2 weeks could be equally effective and safer for tooth whitening than to administer two treatment sessions with HP 37.5%.
Deep learning analyzes Helicobacter pylori infection by upper gastrointestinal endoscopy images.
Itoh, Takumi; Kawahira, Hiroshi; Nakashima, Hirotaka; Yata, Noriko
2018-02-01
Helicobacter pylori (HP)-associated chronic gastritis can cause mucosal atrophy and intestinal metaplasia, both of which increase the risk of gastric cancer. The accurate diagnosis of HP infection during routine medical checks is important. We aimed to develop a convolutional neural network (CNN), which is a machine-learning algorithm similar to deep learning, capable of recognizing specific features of gastric endoscopy images. The goal behind developing such a system was to detect HP infection early, thus preventing gastric cancer. For the development of the CNN, we used 179 upper gastrointestinal endoscopy images obtained from 139 patients (65 were HP-positive: ≥ 10 U/mL and 74 were HP-negative: < 3 U/mL on HP IgG antibody assessment). Of the 179 images, 149 were used as training images, and the remaining 30 (15 from HP-negative patients and 15 from HP-positive patients) were set aside to be used as test images. The 149 training images were subjected to data augmentation, which yielded 596 images. We used the CNN to create a learning tool that would recognize HP infection and assessed the decision accuracy of the CNN with the 30 test images by calculating the sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve (AUC). The sensitivity and specificity of the CNN for the detection of HP infection were 86.7 % and 86.7 %, respectively, and the AUC was 0.956. CNN-aided diagnosis of HP infection seems feasible and is expected to facilitate and improve diagnosis during health check-ups.
Comparative Characteristics of Main Battle Tanks.
1973-06-01
Depth Ford up to 7.4 feet, snorkel 13.1 feet, preparation time for snorkel @ 10 minutes 2-1 June 1973 q.- 4V-~v~W-. U W U U U POWER TRAIN Engine Mercedes ... Benz 4-stroke diesel, 10- cylinder, 900 V upright Engine hp 830 hp @ 2,200 rpm Maximum Torque/rpm 1, 989 ft/lb @ 1, 200 rpm Type Cooling Liquid @ 25
10. BOILER #16 (BUILDING L8) TO LEFT, L.P. AND H.P. ...
10. BOILER #16 (BUILDING L8) TO LEFT, L.P. AND H.P. BOILER ROOMS (BUILDINGS L4 AND L2) TO RIGHT, AND STEPHENS SUBSTATION (BUILDING L6) IN BACKGROUND, FROM THE ROOF OF THE POWERHOUSE EXTENSION (BUILDING L5) - Portland General Electric Company, Station "L", 1841 Southeast Water Street, Portland, Multnomah County, OR
Cornelius, Rena M.; Shankar, Sucharita P.; Brash, John L.; Babensee, Julia E.
2011-01-01
Intact and fragmented proteins, eluted from self assembled monolayer (SAM) surfaces of alkanethiols of different chemistries (-CH3, -OH, -COOH, -NH2 ), following exposure to human plasma (HP) or human serum (HS), were examined using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and immunoblotting techniques. The SAM surfaces were incubated for 1 hour with 10% (v/v) sterile-filtered heat-inactivated (h.i.) HS or 1% (v/v) sterile-filtered h.i. HP preparations [both in phosphate buffered saline (PBS)]. Adsorbed proteins were eluted using 10% SDS/2.3% dithioerythritol for characterization of protein profiles. The type of incubating medium may be an important determinant of adsorbed protein profiles, since some variations were observed in eluates from filtered versus control unfiltered h.i. 10% HS or 1% HP. Albumin and apolipoprotein A1 were consistently detected in both filtered h.i 10% HS and 1% HP eluates from all SAM surfaces and from control tissue culture-treated polystyrene (TCPS). Interestingly, Factor H and Factor I, antithrombin, prothrombin, high molecular weight kininogen (HMWK) and IgG were present in eluates from OH, COOH and NH2 SAM surfaces and in eluates from TCPS, but not in eluates from CH3 SAM surfaces, following exposure to filtered h.i. 10% HS. These results suggest that CH3 SAM surfaces were the least pro-inflammatory of all SAM surfaces. Overall, similar trends were observed in the profiles of proteins eluted from surfaces exposed to filtered 10% HS or 1% HP. However the unique profiles of adsorbed proteins on different SAM surface chemistries may be related to their differential interactions with cells, including immune/inflammatory cells. PMID:21509932
EVALUATION OF EYE LENS DOSES OF INTERVENTIONAL CARDIOLOGISTS.
Yokoyama, Sumi; Suzuki, Shoichi; Toyama, Hiroshi; Arakawa, Shinji; Inoue, Satoshi; Kinomura, Yutaka; Kobayashi, Ikuo
2017-04-01
The effective dose of medical staff members, especially interventional radiologists and cardiologists, is classified as a relatively high level. We measured the dose for interventional cardiologists by using optically stimulated luminescence dosimeters (OSLDs). However, this quantity is not the same as Hp (3). In experiments, the dose at the eye-lens position of a phantom were measured using OSLDs and thermoluminescence dosimeters (TLDs). A conversion factor from dose measured by using TLDs to OSLDs was estimated from these results. In addition, the eye doses of interventional cardiologists in clinical situations were measured, and the effect of eyewear on the eye-lens dose was discussed. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Whole-body protein turnover of a carnivore, Felis silvestris catus.
Russell, K; Lobley, G E; Millward, D J
2003-01-01
The cat (Felis silvestris catus) has a higher dietary protein requirement than omnivores and herbivores, thought to be due to metabolic inflexibility. An aspect of metabolic flexibility was examined with studies of whole-body protein turnover at two levels of dietary protein energy, moderate protein (MP; 20 %) and high protein (HP; 70 %), in five adult cats in a crossover design. Following a 14 d pre-feed period, a single intravenous dose of [15N]glycine was administered and cumulative excretion of the isotope in urine and faeces determined over 48 h. N flux increased (P<0.005) with dietary protein, being 56 (se 5) mmol N/kg body weight (BW) per d for cats fed the MP diet and 146 (se 8) mmol N/kg BW per d for cats fed the HP diet. Protein synthesis was higher (P<0.05) on the HP diet (75 (se 10) mmol N/kg BW per d; 6.6 (se 1) g protein/kg BW per d) than the MP diet (38 (se 5) mmol N/kg BW per d; 3.4 (se 0.4) g protein/kg BW per d). Protein breakdown was higher (P<0.05) on the HP diet (72 (se 8) mmol N/kg BW per d; 6.3 (se 0.7) g protein/kg BW per d) than the MP diet (44 (se 3) mmol N/kg BW per d; 3.9 (se 0.3) g protein/kg BW per d). Compared with other species the rate of whole-body protein synthesis in the well-nourished cat (9.7 (se 1.3) g protein/kg BW0.75 per d) is at the lower end of the range. These results show that feline protein turnover adapts to dietary protein as has been shown in other species and demonstrates metabolic flexibility. Further work is required to determine exactly why cats have such a high protein requirement.
Rong, Wen-Ting; Lu, Ya-Peng; Tao, Qing; Guo, Miao; Lu, Yu; Ren, Yong; Yu, Shu-Qin
2014-02-01
The objective of the study was to evaluate the effect of hydroxypropyl-sulfobutyl-β-cyclodextrin (HP-SBE-βCD) on the bioavailability and intestinal absorption of edaravone, and identify its mechanism of action. We devised HP-SBE-βCD as a carrier and modulator of P-glycoprotein (Pgp) efflux pump, and edaravone as a model drug, and prepared edaravone/HP-SBE-βCD inclusion complex. HP-SBE-βCD improved the water solubility and enhanced the bioavailability of edaravone by 10.3-fold in rats. Then, in situ single-pass intestinal perfusion showed that HP-SBE-βCD had an effect of improving the permeability and inhibiting the efflux of edaravone. Furthermore, the effects of HP-SBE-βCD on Pgp were achieved through interfering with the lipid raft and depleting the cholesterol of enterocytes membrane. From the results, we presented the novel mechanisms. First, edaravone/HP-SBE-βCD had a lower release from the inclusion compound to protect edaravone from the low pH of the stomach. Then, HP-SBE-βCD modulated the membrane microenvironment of intestinal absorption epithelial cells. At last, the result was that HP-SBE-βCD enhanced the absorption of edaravone by interfering with Pgp. In conclusion, HP-SBE-βCD improves the bioavailability of drug not only because of its enhancing water solubility of the drug, but also because it modulates the Pgp-mediated efflux from enterocytes. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association.
Song, Kang; Zhou, Xu; Liu, Yiqi; Gong, Yanyan; Zhou, Beibei; Wang, Dongbo; Wang, Qilin
2016-01-01
Improving dewaterability of sludge is important for the disposal of sludge in wastewater treatment plants (WWTPs). This study, for the first time, investigated the Fe(II) activated oxidization processes in improving anaerobically digested sludge (ADS) dewaterability. The combination of Fe(II) (0–100 mg/g total solids (TS)) and persulfate (0–1,000 mg/g TS) under neutral pH as well as the combination of Fe(II) (0–100 mg/g TS) and hydrogen peroxide (HP) (0–1,000 mg/g TS) under pH 3.0 were used to examine and compare their effect on the ADS dewaterability enhancement. The highest ADS dewaterability enhancement was attained at 25 mg Fe(II)/g TS and 50 mg HP/g TS, when the CST (CST: the capillary suction time, a sludge dewaterability indicator) was reduced by 95%. In contrast, the highest CST reduction in Fe(II)-persulfate conditioning was 90%, which was obtained at 50 mg Fe(II)/g TS and 250 mg persulfate/g TS. The results showed that Fe(II)-HP conditioning was comparable with Fe(II)-persulfate conditioning in terms of highest CST reduction. Economic analysis suggested that the Fe(II)-HP conditioning was more promising for improving ADS dewaterability compared with Fe(II)-persulfate conditioning, with the saving being up to $65,000 per year in a WWTP with a population equivalent of 100,000. PMID:27109500
Dynamic Culturing of Cartilage Tissue: The Significance of Hydrostatic Pressure
Pereira, Ana L.; Duarte, Ana R.C.; Frias, Ana M.; Pedro, Adriano J.; Oliveira, João T.; Sousa, Rui A.; Reis, Rui L.
2012-01-01
Human articular cartilage functions under a wide range of mechanical loads in synovial joints, where hydrostatic pressure (HP) is the prevalent actuating force. We hypothesized that the formation of engineered cartilage can be augmented by applying such physiologic stimuli to chondrogenic cells or stem cells, cultured in hydrogels, using custom-designed HP bioreactors. To test this hypothesis, we investigated the effects of distinct HP regimens on cartilage formation in vitro by either human nasal chondrocytes (HNCs) or human adipose stem cells (hASCs) encapsulated in gellan gum (GG) hydrogels. To this end, we varied the frequency of low HP, by applying pulsatile hydrostatic pressure or a steady hydrostatic pressure load to HNC-GG constructs over a period of 3 weeks, and evaluated their effects on cartilage tissue-engineering outcomes. HNCs (10×106 cells/mL) were encapsulated in GG hydrogels (1.5%) and cultured in a chondrogenic medium under three regimens for 3 weeks: (1) 0.4 MPa Pulsatile HP; (2) 0.4 MPa Steady HP; and (3) Static. Subsequently, we applied the pulsatile regimen to hASC-GG constructs and varied the amplitude of loading, by generating both low (0.4 MPa) and physiologic (5 MPa) HP levels. hASCs (10×106 cells/mL) were encapsulated in GG hydrogels (1.5%) and cultured in a chondrogenic medium under three regimens for 4 weeks: (1) 0.4 MPa Pulsatile HP; (2) 5 MPa Pulsatile HP; and (3) Static. In the HNC study, the best tissue development was achieved by the pulsatile HP regimen, whereas in the hASC study, greater chondrogenic differentiation and matrix deposition were obtained for physiologic loading, as evidenced by gene expression of aggrecan, collagen type II, and sox-9; metachromatic staining of cartilage extracellular matrix; and immunolocalization of collagens. We thus propose that both HNCs and hASCs detect and respond to physical forces, thus resembling joint loading, by enhancing cartilage tissue development in a frequency- and amplitude-dependant manner. PMID:22559784
SU-F-T-653: Radiation Exposure from Cs-131 Permanent Seed Implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giaddui, T; Hardin, M; To, D
Purpose: Permanent seed implants have traditionally been used to treat prostate, lung and head or neck cancers using I-125 and Pd-103. Cs-131, which has higher dose rate is being used to treat brain, head and/or neck cancers in our clinic, therefore, we chose to monitor the dose received by surgeons during the extensive procedure. The aims of this work are to assess the level of radiation exposure to surgeons and the instantaneous exposure at bedside and 1 m from patients. Methods: Ten patients received Cs-131 implants for recurrent brain,head and/or neck cancer; the median implanted activity, number of implanted seedsmore » and prescription dose at 0.5 cm from the perpendicular plane of the implant were: 54.3 mCi (14.52 – 77); 19 (4 – 24) and 60 Gy (range 42 – 60) respectively. Radiation exposure was recorded at bedside and 1 m from the patient using Victoreen ion chamber (Fluke Biomedical, Cleveland, OH). Exposure to surgeons was measured using TLD (Mirion Technologies (GDS), Inc., USA). Results: The median equivalent dose rate at 1 m and bedside immediately following implantation were 1.49×10-2 mSv/h (8.77×10-3–2.63×10-2) and 7.76×10-2 mSv/h (3.1×10-2– 1.53×10-1) respectively. Median equivalent dose to surgeons’ hands was 0.60 mSv (0.33 – 1.48) and no doses were detected for whole-body. Surgical reconstruction for one patient was performed 71 days post-implant and resulted in zero exposure to surgeons. Conclusion: The recorded exposure rates were low when compared with the literature. Post procedure surveys at bed site and 1 m indicated that all patients were within safe limits for discharge (< 0.05 mSv/h at 1 m). However, as a precautionary measure, patients were advised to avoid direct contact with children and pregnant women within four weeks of the implant and stay at least at 3 ft from other people. Surgeons doses were well within occupational dose limits.« less
Abou-Taleb, W M; Hassan, M H; El Mallah, E A; Kotb, S M
2018-05-01
Photoneutron production, and the dose equivalent, in the head assembly of the 15 MV Elekta Precise medical linac; operating in the faculty of Medicine at Alexandria University were estimated with the MCNP5 code. Photoneutron spectra were calculated in air and inside a water phantom to different depths as a function of the radiation field sizes. The maximum neutron fluence is 3.346×10 -9 n/cm 2 -e for a 30×30 cm 2 field size to 2-4 cm-depth in the phantom. The dose equivalent due to fast neutron increases as the field size increases, being a maximum of 0.912 ± 0.05 mSv/Gy at depth between 2 and 4 cm in the water phantom for 40×40 cm 2 field size. Photoneutron fluence and dose equivalent are larger to 100 cm from the isocenter than to 35 cm from the treatment room wall. Copyright © 2018 Elsevier Ltd. All rights reserved.
Joshi, Anuja; Gislason-Lee, Amber J; Keeble, Claire; Sivananthan, Uduvil M
2017-01-01
Objective: The aim of this research was to quantify the reduction in radiation dose facilitated by image processing alone for percutaneous coronary intervention (PCI) patient angiograms, without reducing the perceived image quality required to confidently make a diagnosis. Methods: Incremental amounts of image noise were added to five PCI angiograms, simulating the angiogram as having been acquired at corresponding lower dose levels (10–89% dose reduction). 16 observers with relevant experience scored the image quality of these angiograms in 3 states—with no image processing and with 2 different modern image processing algorithms applied. These algorithms are used on state-of-the-art and previous generation cardiac interventional X-ray systems. Ordinal regression allowing for random effects and the delta method were used to quantify the dose reduction possible by the processing algorithms, for equivalent image quality scores. Results: Observers rated the quality of the images processed with the state-of-the-art and previous generation image processing with a 24.9% and 15.6% dose reduction, respectively, as equivalent in quality to the unenhanced images. The dose reduction facilitated by the state-of-the-art image processing relative to previous generation processing was 10.3%. Conclusion: Results demonstrate that statistically significant dose reduction can be facilitated with no loss in perceived image quality using modern image enhancement; the most recent processing algorithm was more effective in preserving image quality at lower doses. Advances in knowledge: Image enhancement was shown to maintain perceived image quality in coronary angiography at a reduced level of radiation dose using computer software to produce synthetic images from real angiograms simulating a reduction in dose. PMID:28124572
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neustadter, David; Barnea, Gideon; Stokar, Saul
Purpose: A fiducial tracking system based on a novel radioactive tracking technology is being developed for real-time target tracking in radiation therapy. In this study, the authors calculate the radiation dose to the patient, the spouse/caretaker, and the medical staff that would result from a 100 {mu}Ci Ir192 radioactive fiducial marker permanently implanted in the prostate of a radiation therapy patient. Methods: Local tissue dose was calculated by Monte Carlo simulation. The patient's whole body effective dose equivalent was calculated by summing the doses to the sensitive organs. Exposure of the spouse/caretaker was calculated from the NRC guidelines. Exposure ofmore » the medical staff was based on estimates of proximity to and time spent with the patient. Results: The local dose is below 40 Gy at 5 mm from the marker and below 10 Gy at 10 mm from the marker. The whole body effective dose equivalent to the patient is 64 mSv. The dose to the spouse/caretaker is 0.25 mSv. The annual exposures of the medical staff are 0.2 mSv for a doctor performing implantations and 0.34 mSv for a radiation therapist positioning patients for therapy. Conclusions: The local dose is not expected to have any clinically significant effect on the surrounding tissue which is irradiated during therapy. The dose to the patient is small in comparison to the whole body dose received from the therapy itself. The exposure of all other people is well below the recommended limits. The authors conclude that there is no radiation exposure related contraindication for use of this technology in the radiation treatment of prostate cancer.« less
NASA Astrophysics Data System (ADS)
Ohba, Takashi; Hasegawa, Arifumi; Kohayakawa, Yoshitaka; Kondo, Hisayoshi; Suzuki, Gen
2017-09-01
To reduce uncertainty in thyroid dose estimation, residents' radiation protection behavior should be reflected in the estimation. Screening data of body surface contamination provide information on exposure levels during evacuation. Our purpose is to estimate thyroid equivalent doses based on body surface contamination levels using a new methodology. We obtained a record of 7,539 residents/evacuees. Geiger-Mueller survey meter measurement value in cpm was translated into Bq/cm2 according to the nuclides densities obtained by measuring clothing from two persons by germanium γ-spectrometer. The measurement value of body surface contamination on head was adjusted by a natural removal rate of 15 hours and radionuclides' physical half-life. Thyroid equivalent dose of 1-year-old children by inhalation was estimated by two-dimensional Monte Carlo simulation. The proportions of evacuees/residents with measurement value in cpm of Namie and Minamisoma groups were higher than those of other groups during both periods (p<0.01, Kruskal-Wallis). During 12-14 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were estimated as 2.7 and 86.0 mSv, respectively, for Namie group, and 4.2 and 17.2 mSv, respectively, for Minamisoma group, 0.1 and 1.0 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 0.2 and 2.1 mSv, respectively, for the other group. During 15- 17 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were 0.8 and 15.7 mSv, respectively, for Namie group, and 1.6 and 8.4 mSv, respectively, for Minamisoma group, 0.2 and 13.2 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 1.2 and 12.7 mSv, respectively, for the other group. It was indicated that inhalation dose was generally higher in Namie and Minamisoma groups during 12-14 March than those during 15-17 March might reflect different self-protective behavior to radioactive plumes from other groups.
Burns, Monika; Amaya, Aldo; Bodi, Caroline; Ge, Zhongming; Bakthavatchalu, Vasudevan; Ennis, Kathleen; Wang, Timothy C.; Georgieff, Michael
2017-01-01
Helicobacter pylori (H.pylori), a bacterial pathogen, is a causative agent of gastritis and peptic ulcer disease and is a strong risk factor for development of gastric cancer. Environmental conditions, such as poor dietary iron resulting in iron deficiency anemia (IDA), enhance H.pylori virulence and increases risk for gastric cancer. IDA affects billions of people worldwide, and there is considerable overlap between regions of high IDA and high H.pylori prevalence. The primary aims of our study were to evaluate the effect of H.pylori infection on behavior, iron metabolism, red blood cell indices, and behavioral outcomes following comorbid H. pylori infection and dietary iron deficiency in a mouse model. C57BL/6 female mice (n = 40) were used; half were placed on a moderately iron deficient (ID) diet immediately post-weaning, and the other half were maintained on an iron replete (IR) diet. Half were dosed with H.pylori SS1 at 5 weeks of age, and the remaining mice were sham-dosed. There were 4 study groups: a control group (-Hp, IR diet) as well as 3 experimental groups (-Hp, ID diet; +Hp, IR diet; +Hp,ID diet). All mice were tested in an open field apparatus at 8 weeks postinfection. Independent of dietary iron status, H.pylori -infected mice performed fewer exploratory behaviors in the open field chamber than uninfected mice (p<0.001). Hippocampal gene expression of myelination markers and dopamine receptor 1 was significantly downregulated in mice on an ID diet (both p<0.05), independent of infection status. At 12 months postinfection, hematocrit (Hct) and hemoglobin (Hgb) concentration were significantly lower in +Hp, ID diet mice compared to all other study groups. H.pylori infection caused IDA in mice maintained on a marginal iron diet. The mouse model developed in this study is a useful model to study the neurologic, behavioral, and hematologic impact of the common human co-morbidity of H. pylori infection and IDA. PMID:28355210
Mackenzie, Lynette; Byles, Julie
2018-03-30
Falls in older people are a major public health concern. To target falls prevention interventions, screening tools need to be able to identify older people at greater risk of falling. This study aimed to investigate the screening capacity of the Home Falls and Accidents Screening Tool for health professionals (HOME FAST-HP), and to identify the best cut-off score to identify older people at higher risk of falls using the HOME FAST-HP. The study used cross-sectional data from a random sample of 650 women from the 1921 to 1926 cohort of the Australian Longitudinal Study of Women's Health (ALSWH). Selected women were sent a postal survey including the HOME FAST-HP, falls history, and other health factors. Scores on the home fast were calculated and the cut-point for optimal sensitivity and specificity of the HOME FAST-HP in relation to falls was assessed using a Receiver Operating Characteristic curve. A total of 567 older women participated (response rate 87%). The mean age of participants was 77.5 yrs (95% CI 77.31-77.70). A total of 153 participants (27%) reported a fall in the previous six months. The mean number of hazards using the HOME FAST-HP was 9.74 (95% CI 9.48-10.01), range 2-22. Non-fallers had a mean of 9.6 hazards (95% CI 9.32-9.91) and fallers had a mean of 10.63 hazards (95% CI 10.08-11.19) which was a significant difference (t = 3.41, P = 0.001). The area under the receiver operator curve (AUC) was 0.58 (95% CI 0.53-0.64). A HOME FAST-HP cut-off score of 9 was associated with the optimal sensitivity for falls (73.9%), with specificity (37.9%), and positive predictive value was 30.6% and negative predictive value was 79.7%. The HOME FAST-HP can be used as a screening tool to identify fallers with a cut-off score of nine indicating a higher risk of falling. © 2018 Occupational Therapy Australia.
Rodríguez Pérez, Sunay; Marshall, Nicholas William; Struelens, Lara; Bosmans, Hilde
2018-01-01
This work concerns the validation of the Kyoto-Kagaku thorax anthropomorphic phantom Lungman for use in chest radiography optimization. The equivalence in terms of polymethyl methacrylate (PMMA) was established for the lung and mediastinum regions of the phantom. Patient chest examination data acquired under automatic exposure control were collated over a 2-year period for a standard x-ray room. Parameters surveyed included exposure index, air kerma area product, and exposure time, which were compared with Lungman values. Finally, a voxel model was developed by segmenting computed tomography images of the phantom and implemented in PENELOPE/penEasy Monte Carlo code to compare phantom tissue-equivalent materials with materials from ICRP Publication 89 in terms of organ dose. PMMA equivalence varied depending on tube voltage, from 9.5 to 10.0 cm and from 13.5 to 13.7 cm, for the lungs and mediastinum regions, respectively. For the survey, close agreement was found between the phantom and the patients' median values (deviations lay between 8% and 14%). Differences in lung doses, an important organ for optimization in chest radiography, were below 13% when comparing the use of phantom tissue-equivalent materials versus ICRP materials. The study confirms the value of the Lungman for chest optimization studies.
Millar, W T; Davidson, S E
2013-01-01
Objective: To consider the implications of the use of biphasic rather than monophasic repair in calculations of biologically-equivalent doses for pulsed-dose-rate brachytherapy of cervix carcinoma. Methods: Calculations are presented of pulsed-dose-rate (PDR) doses equivalent to former low-dose-rate (LDR) doses, using biphasic vs monophasic repair kinetics, both for cervical carcinoma and for the organ at risk (OAR), namely the rectum. The linear-quadratic modelling calculations included effects due to varying the dose per PDR cycle, the dose reduction factor for the OAR compared with Point A, the repair kinetics and the source strength. Results: When using the recommended 1 Gy per hourly PDR cycle, different LDR-equivalent PDR rectal doses were calculated depending on the choice of monophasic or biphasic repair kinetics pertaining to the rodent central nervous and skin systems. These differences virtually disappeared when the dose per hourly cycle was increased to 1.7 Gy. This made the LDR-equivalent PDR doses more robust and independent of the choice of repair kinetics and α/β ratios as a consequence of the described concept of extended equivalence. Conclusion: The use of biphasic and monophasic repair kinetics for optimised modelling of the effects on the OAR in PDR brachytherapy suggests that an optimised PDR protocol with the dose per hourly cycle nearest to 1.7 Gy could be used. Hence, the durations of the new PDR treatments would be similar to those of the former LDR treatments and not longer as currently prescribed. Advances in knowledge: Modelling calculations indicate that equivalent PDR protocols can be developed which are less dependent on the different α/β ratios and monophasic/biphasic kinetics usually attributed to normal and tumour tissues for treatment of cervical carcinoma. PMID:23934965
Experimental search for hidden photon CDM in the eV mass range with a dish antenna
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, J.; Horie, T.; Inoue, Y.
2015-09-15
A search for hidden photon cold dark matter (HP CDM) using a new technique with a dish antenna is reported. From the result of the measurement, we found no evidence for the existence of HP CDM and set an upper limit on the photon-HP mixing parameter χ of ∼6×10{sup −12} for the hidden photon mass m{sub γ}=3.1±1.2 eV.
Soncin, M; Busetti, A; Fusi, F; Jori, G; Rodgers, M A
1999-06-01
Cu(II)-hematoporphyrin (CuHp) was efficiently accumulated by B78H1 amelanotic melanoma cells upon incubation with porphyrin concentrations up to 52 microM. When the cells incubated for 18 h with 13 microM CuHp were irradiated with 532 nm light from a Q-switched Nd: YAG laser operated in a pulsed mode (10 ns pulses, 10 Hz) a significant decrease in cell survival was observed. The cell photoinactivation was not the consequence of a photodynamic process, as CuHp gave no detectable triplet signal upon laser flash photolysis excitation and no decrease in cell survival was observed upon continuous wave irradiation. Thus, it is likely that CuHp sensitization takes place by photothermal pathways. The efficiency of the photoprocess was modulated by different parameters; thus, while varying the amount of added CuHp in the 3.25-26 microM range had little effect, pulse energies larger than 50 mJ and irradiation times of at least 120 s were necessary to induce a cell inactivation of about 50%. The porphyrin-cell incubation time prior to irradiation had a major influence on cell survival, suggesting that the nature of the CuHp microenvironment can control the efficiency of photothermal sensitization.
NASA Astrophysics Data System (ADS)
Szumska, Agnieszka; Budzanowski, M.; Kopeć, R.
2014-11-01
We report results of measurements of Hp(10) from whole body dosimeters (about 53 thousand readouts), of Hp(0.07) from finger ring dosimeters (23 thousand readouts) and of Hp(3) from eye lens dosimeters (100 readouts), issued in the years 2010-12 to over 150 medical departments in Poland which apply X-rays in radiology, interventional radiology (haemodynamic, angiology, cardiac surgery), urology, orthopaedics, electrophysiology or electro-cardiology. In all measurements thermoluminescence detectors (TLD) were used: the well-known standard MTS-N (LiF:Mg, Ti) for whole body and extremity dosimetry, and the high-sensitivity MCP-N (LiF:Mg, Cu, P) for eye lens dosimetry and environmental monitoring. We analysed the data base of the accredited Laboratory of Individual and Environmental Dosimetry (LADIS) at the Institute of Nuclear Physics PAN which offers its dosimetry service to these departments on a regular basis. We found that in the population of radiation workers that studied over the years 2010-2012 in 84%, 87%, and 34% of Hp(10), Hp(0.07) and Hp(3) measurements, respectively, the level of 0.1 mSv/quarter did not exceed, indicating lack of their occupational exposure. In the remaining 16%, 13% and 66% of individual cases, the 0.1 mSv/quarter exceeded, occasionally reaching several hundreds of mSv/quarter.
Wang, Fazhan; Bao, Xingting; Fang, Aiping; Li, Huili; Zhou, Yang; Liu, Yongmei; Jiang, Chunling; Wu, Jinhui; Song, Xiangrong
2018-01-01
Novel ocular drug delivery systems (NODDSs) remain to be explored to overcome the anatomical and physiological barriers of the eyes. This study was to encapsulate brinzolamide (BRZ)-hydropropyl-β-cyclodextrin (HP-β-CD) inclusion complex (HP-β-CD/BRZ) into nanoliposomes and investigate its potential as one of NODDS to improve BRZ local glaucomatous therapeutic effect. HP-β-CD/BRZ was firstly prepared to enhance the solubility of poorly water-soluble BRZ. The HP-β-CD/BRZ loaded nanoliposomes (BCL) were subsequently constructed by thin-film dispersion method. After the optimization of the ratio of BRZ to HP-β-CD, the optimal BCL showed an average size of 82.29 ± 6.20 nm, ζ potential of -3.57 ± 0.46 mV and entrapment efficiency (EE) of 92.50 ± 2.10% with nearly spherical in shape. The X-ray diffraction (XRD) confirmed the formation of HP-β-CD/BRZ and BCL. The in vitro release study of BCL was evaluated using the dialysis technique, and BCL showed moderate sustained release. BCL (1 mg/mL BRZ) showed a 9.36-fold increase in the apparent permeability coefficient and had a sustained and enhanced intraocular pressure reduction efficacy when compared with the commercially available formulation (BRZ-Sus) (10 mg/mL BRZ). In conclusion, BCL might have a promising future as a NODDS for glaucoma treatment. PMID:29487529
Berger, Sandrine Bittencourt; Guiraldo, Ricardo Danil; Lopes, Murilo Baena; Oltramari-Navarro, Paula Vanessa; Fernandes, Thais Maria; Schwertner, Renata de Castro Alves; Ursi, Wagner José Silva
2016-01-01
The application of bleaching agents before placement of resin-bonded fixed appliances significantly, but temporarily, reduces bond strength to tooth structure. Antioxidants have been studied as a means to remove residual oxygen that compromises bonding to bleached enamel. This in vitro study evaluated whether green tea (GT) could restore the shear bond strength between bonded orthodontic brackets and bleached enamel. Six experimental groups were compared: group 1, no bleaching plus bracket bonding (positive control); group 2, bleaching with 35% hydrogen peroxide (HP) plus bracket bonding (negative control); group 3, 35% HP plus 10% sodium ascorbate (SA) plus bracket bonding; group 4, 35% HP plus 10% GT plus bracket bonding; group 5, no bleaching plus 10% SA plus bracket bonding; group 6, no bleaching plus 10% GT plus bracket bonding. Results suggested that GT, like SA, may be beneficial for bracket bonding immediately after bleaching.
Lucero, Yalda; Oyarzún, Amaya; O'Ryan, Miguel; Quera, Rodrigo; Espinosa, Nelly; Valenzuela, Romina; Simian, Daniela; Alcalde, Elisa; Arce, Claudio; Farfán, Mauricio J.; Vergara, Alejandra F.; Gajardo, Iván; Mendez, Jocelyn; Carrasco, Jorge; Errázuriz, Germán; Gonzalez, Mónica; Ossa, Juan C.; Maiza, Eduardo; Perez-Bravo, Francisco; Castro, Magdalena; Araya, Magdalena
2017-01-01
HIGHLIGHTS What is already known about this subject?Celiac disease (CD) has a high clinical and histological diversity and the mechanisms underlying this phenomenon remain elusive.H. pylori is a bacterium that chronically infect gastric and duodenal mucosa activating both a Th1/Th17 and T-reg pathways.The role of H. pylori (and the effect of their virulence factors) in CD have not yet completely elucidated.What are the new findings?cagA+ H. pylori strains are associated to milder histological damage in infected CD patients.In active-CD patients the presence of cagA+ H. pylori is associated to an increase in T-reg markers, contrasting with a downregulation in cagA+ infected potential-CD individuals.How might it impact on clinical practice in the foreseeable future?The identification of microbiological factors that could modulate inflammation and clinical expression of CD may be used in the future as preventive strategies or as supplementary treatment in patients that cannot achieve complete remission, contributing to the better care of these patients. Background: Mechanisms underlying the high clinical and histological diversity of celiac disease (CD) remain elusive. Helicobacter pylori (Hp) chronically infects gastric and duodenal mucosa and has been associated with protection against some immune-mediated conditions, but its role (specifically of cagA+ strains) in CD is unclear. Objective: To assess the relationship between gastric Hp infection (cagA+ strains) and duodenal histological damage in patients with CD. Design: Case-control study including patients with active-CD, potential-CD and non-celiac individuals. Clinical presentation, HLA genotype, Hp/cagA gene detection in gastric mucosa, duodenal histology, Foxp3 positive cells and TGF-β expression in duodenal lamina propria were analyzed. Results: We recruited 116 patients, 29 active-CD, 37 potential-CD, and 50 non-CD controls. Hp detection was similar in the three groups (~30–40%), but cagA+ strains were more common in infected potential-CD than in active-CD (10/11 vs. 4/10; p = 0.020) and non-CD (10/20; p = 0.025). Among active-CD patients, Foxp3 positivity was significantly higher in subjects with cagA+ Hp+ compared to cagA- Hp+ (p < 0.01) and Hp- (p < 0.01). In cagA+ Hp+ individuals, Foxp3 positivity was also higher comparing active- to potential-CD (p < 0.01). TGF-β expression in duodenum was similar in active-CD with cagA+ Hp+ compared to Hp- and was significantly downregulated in cagA+ potential-CD subjects compared to other groups. Conclusion: Hp infection rates were similar among individuals with/without CD, but infection with cagA+ strains was associated with milder histological damage in celiac patients infected by Hp, and in active-CD cases with higher expression of T-reg markers. Results suggest that infection by cagA+ Hp may be protective for CD progression, or conversely, that these strains are prone to colonize intestinal mucosa with less severe damage. PMID:28879170
Gingerich, W.H.; Meinertz, J.R.; Dawson, V.K.; Gofus, J.E.; Delaney, L.J.; Bunnell, P.R.
1995-01-01
The distribution and loss of radioactivity from tissues were determined in 60 juvenile channel catfish (Ictalurus punctatus) following oral dosing with the candidate fish therapeutant Sarafin® ([14C] sarafloxacin hydrochloride) at 10 mg/kg for 5 consecutive days. Twelve groups of 5 fish each were sampled at selected times ranging from 3 to 240 h after the last dose was administered, The concentration and content of sarafloxacin-equivalent activity was determined in liver, gallbladder, kidney, skin, and skinless fillet by sample oxidation and liquid scintillation counting; content of sarafloxacin-equivalent activity was determined in stomach and anterior and posterior intestines, Skinless fillet tissues were also analyzed for sarafloxacin and for potential metabolites by gradient-elution high-performance liquid chromatography (HPLC) with in-line radiometric and fluorescence detection, Loss of radioactivity from the whole body conformed to a bimodal elimination pattern with a rapid initial phase (t1/2=11 h) and a slower secondary phase (t1/2=222 h). Tissue and contents of the gastrointestinal tract (i.e. stomach and anterior and posterior intestines) were a principal depot of activity during the first four sample times (3, 6, 12, and 24 h); the combined head, skeleton, and fins (i.e. residual carcass) were the principal depot of activity in samples taken after 24 h. Of those tissues sampled 3 h after the last dose, relative sarafloxacin concentration was greatest in the liver (4.06 μg equivalents/g) and least in the residual carcass (1.13 μg equivalents/g), Intermediate concentrations were found in the kidney (2.04 μg equivalents/g), skinless fillet (1.71 μg equivalents/ g), and the skin (1.51 μg equivalents/g). Concentrations of sarafloxacin-equivalent residues in edible skinless fillet were consistently among the lowest of all tissues examined. The highest mean concentration of parent-equivalent material in the fillet tissue was found 12 h after administration of the last dose (2.27 μg equivalents/g) and declined thereafter, Sarafloxacin constituted between 80 and 90% of the extractable radioactive residues from the fillet homogenates. No other peaks were resolved in any of the fillet tissue samples analyzed by HPLC with in-line radiometric detection.
Hypotensive effects of hemopressin and bradykinin in rabbits, rats and mice. A comparative study.
Blais, Paul-André; Côté, Jérôme; Morin, Josée; Larouche, Annie; Gendron, Gabrielle; Fortier, Audrey; Regoli, Domenico; Neugebauer, Witold; Gobeil, Fernand
2005-08-01
Hemopressin is a novel vasoactive nonapeptide derived from hemoglobin's alpha-chain as recently reported by Rioli et al. [Rioli V, Gozzo FC, Heimann AS, Linardi A, Krieger JE, Shida CS, et al. Novel natural peptide substrates for endopeptidase 24.15, neurolysin, and angiotensin-converting enzyme. J Biol Chem 2003;278(10):8547-55]. In anesthetized male Wistar rats, this peptide exhibited hypotensive actions similar to those of bradykinin (BK) when administered intravenously (i.v.), and was found to be metabolized both in vitro and in vivo by several peptidases, including the angiotensin-converting enzyme (ACE). In this study, these findings were expanded upon by examining: (i) the degradation kinetics following incubation with ACE purified from rabbit lung and (ii) the blood pressure lowering effects of HP and BK injected i.v. or intra-arterially (i.a.) in male rabbits, rats, and mice. Our findings demonstrate that, in vitro, HP and BK are both degraded by ACE, but at different velocity rates. Furthermore, both HP and BK induced transient hypotension in all animals tested, although the responses to HP relative to the administration sites were significantly lower (by 10-100-fold) on an equimolar basis compared to those of BK. In rabbits, the decrease of blood pressure induced by HP (10-100 nmol/kg) did not differ whether it was administered i.v. or i.a., suggesting an absence of pulmonary/cardiac inactivation in contrast to BK (0.1-1 nmol/kg). The in vivo effect of HP was significantly potentiated in rabbits immunostimulated with bacterial lipopolysaccharide (LPS), but was unaffected by both the B2 receptor antagonist HOE 140 (0.1 micromol/kg) and captopril (100 microg/kg), contrary to BK. Therefore, HP acts as a weak hypotensive mediator, which does not activate kinin B2 receptors, but uses a functional site and/or signaling paths appearing to be up-regulated by LPS.
Lai, Kung-Ming; Chi, Hsin-Yi; Hsu, Kuo-Chiang
2010-01-01
Whole oysters were processed using high-pressure (HP) treatment at 250 and 300 MPa for 0 to 10 min and stored at 4 degrees Celsius for up to 28 days. HP-treated oysters and untreated oysters were evaluated for lipid oxidation, growth of microorganisms, and sensory characteristics after cooking at 160 degrees Celsius for 90 s. Microbial counts after HP treatment revealed that the bacterial load was initially reduced at all pressures. HP-treated oysters had significantly higher pH and moisture (P < 0.05) relative to control (untreated) oysters during storage. HP treatment increased lipid oxidation with unpleasant odor during storage compared with the control. HP treatment decreased redness but did not significantly affect the brightness and yellowness of cooked oysters. From tests of mechanical properties, 300 MPa-treated oysters after cooking had significantly increased toughness as measured by cutting force. HP-treated oysters after cooking received higher quality scores than did the control during the storage trial. Results indicated that 300 MPa for 2 min is the optimum HP treatment that results in oysters most acceptable for oyster omelets during storage at 4 degrees Celsius, and this treatment may extend the shelf life of these oysters to 21 days.
NASA Astrophysics Data System (ADS)
Shigematsu, T.; Hayashi, M.; Nakajima, K.; Uno, Y.; Sakano, A.; Murakami, M.; Narahara, Y.; Ueno, S.; Fujii, T.
2010-03-01
High hydrostatic pressure (HP) with approximately below 400 MPa can induce a transformation of food materials to an alternative form, where membrane systems are damaged but certain enzymes are still active. HP treatment of water soaked brown rice grain could modify the mass transfer inside and apparent activities of enzymes, resulting in HP-dependent change of distribution of free amino acids. Thus, the distribution of free amino acids in brown rice grain during preservation after HP treatment was analyzed. Just after HP treatment at 200 MPa for 10 min, the distribution of free amino acids was not apparently different from that of untreated control. In contrast, after 1 to 4 days preservation at 25°C, amino acids, such as Ala, Glu, Gly, Asp and Val, showed higher concentrations than those in control. This result suggested that HP treatment induced proteolysis to produce free amino acids. However, Gln, Thr and Cys, showed no apparent difference, suggesting that conversion of certain amino acids produced by proteolysis occurred. Moreover, the concentration of γ-aminobutyric acid (GABA) in HP-treated sample was higher than that in untreated control. These results suggested that HP treatment induced alteration of distribution of free amino acids of rice grains via proteolysis and certain amino acids metabolism pathways.
Prideaux, Andrew R.; Song, Hong; Hobbs, Robert F.; He, Bin; Frey, Eric C.; Ladenson, Paul W.; Wahl, Richard L.; Sgouros, George
2010-01-01
Phantom-based and patient-specific imaging-based dosimetry methodologies have traditionally yielded mean organ-absorbed doses or spatial dose distributions over tumors and normal organs. In this work, radiobiologic modeling is introduced to convert the spatial distribution of absorbed dose into biologically effective dose and equivalent uniform dose parameters. The methodology is illustrated using data from a thyroid cancer patient treated with radioiodine. Methods Three registered SPECT/CT scans were used to generate 3-dimensional images of radionuclide kinetics (clearance rate) and cumulated activity. The cumulated activity image and corresponding CT scan were provided as input into an EGSnrc-based Monte Carlo calculation: The cumulated activity image was used to define the distribution of decays, and an attenuation image derived from CT was used to define the corresponding spatial tissue density and composition distribution. The rate images were used to convert the spatial absorbed dose distribution to a biologically effective dose distribution, which was then used to estimate a single equivalent uniform dose for segmented volumes of interest. Equivalent uniform dose was also calculated from the absorbed dose distribution directly. Results We validate the method using simple models; compare the dose-volume histogram with a previously analyzed clinical case; and give the mean absorbed dose, mean biologically effective dose, and equivalent uniform dose for an illustrative case of a pediatric thyroid cancer patient with diffuse lung metastases. The mean absorbed dose, mean biologically effective dose, and equivalent uniform dose for the tumor were 57.7, 58.5, and 25.0 Gy, respectively. Corresponding values for normal lung tissue were 9.5, 9.8, and 8.3 Gy, respectively. Conclusion The analysis demonstrates the impact of radiobiologic modeling on response prediction. The 57% reduction in the equivalent dose value for the tumor reflects a high level of dose nonuniformity in the tumor and a corresponding reduced likelihood of achieving a tumor response. Such analyses are expected to be useful in treatment planning for radionuclide therapy. PMID:17504874
Assessment of natural radionuclides and its radiological hazards from tiles made in Nigeria
NASA Astrophysics Data System (ADS)
Joel, E. S.; Maxwell, O.; Adewoyin, O. O.; Ehi-Eromosele, C. O.; Embong, Z.; Saeed, M. A.
2018-03-01
Activity concentration of 10 different brands of tiles made in Nigeria were analyzed using High purity Germanium gamma detector and its hazard indices such as absorbed dose rate, radium equivalent activity, external Hazard Index (Hex), internal Hazard Index (Hin), Annual Effective Dose (mSv/y), Gamma activity Index (Iγ) and Alpha Index (Iα) were determined. The result showed that the average activity concentrations of radionuclides (226Ra, 232Th and 40K) content are within the recommended limit. The average radium equivalent is within the recommended limit of 370 Bq/kg. The result obtained further showed that the mean values for the absorbed dose rate (D), external and internal hazard index, the annual effective dose (AEDR) equivalent, gamma activity index and Alpha Index were: 169.22 nGyh-1, 0.95 and 1.14, 1.59 mSv/y, 1.00 Sv yr-1 and 0.34 respectively. The result established that radiological hazards such as absorbed dose rate, internal hazard, annual effective dose rate, gamma activity index and Alpha Index for some samples are found to be slightly close or above international recommended values. The result for the present study was compared with tiles sample from others countries, it was observed that the concentration of tiles made in Nigeria and other countries are closer, however recommends proper radiation monitoring for some tiles made in Nigeria before usage due to the long term health effect.
RCT: Module 2.06, Air Sampling Program and Methods, Course 8772
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hillmer, Kurt T.
The inhalation of radioactive particles is the largest cause of an internal radiation dose. Airborne radioactivity measurements are necessary to ensure that the control measures are and continue to be effective. Regulations govern the allowable effective dose equivalent to an individual. The effective dose equivalent is determined by combining the external and internal dose equivalent values. Typically, airborne radioactivity levels are maintained well below allowable levels to keep the total effective dose equivalent small. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examinationmore » (TEST 27566) and will provide in-the-field skills.« less
Passive dosimetry aboard the Mir Orbital Station: internal measurements.
Benton, E R; Benton, E V; Frank, A L
2002-10-01
Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.
Measurement of dose equivalent distribution on-board commercial jet aircraft.
Kubančák, J; Ambrožová, I; Ploc, O; Pachnerová Brabcová, K; Štěpán, V; Uchihori, Y
2014-12-01
The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them [International Commission on Radiation Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21: (1-3), (1991)]. According to the Monte Carlo simulations [Battistoni, G., Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the doses to aircrew members taking into consideration the aircraft structures. Adv. Space Res. 36: , 1645-1652 (2005) and Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the influence of aircraft shielding on the aircrew exposure through an aircraft mathematical model. Radiat. Prot. Dosim. 108: (2), 91-105 (2004)], the ambient dose equivalent rate Ḣ*(10) depends on the location in the aircraft. The aim of this article is to experimentally evaluate Ḣ*(10) on-board selected types of aircraft. The authors found that Ḣ*(10) values are higher in the front and the back of the cabin and lesser in the middle of the cabin. Moreover, total dosimetry characteristics obtained in this way are in a reasonable agreement with other data, in particular with the above-mentioned simulations. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Marsolat, F; Tromson, D; Tranchant, N; Pomorski, M; Le Roy, M; Donois, M; Moignau, F; Ostrowsky, A; De Carlan, L; Bassinet, C; Huet, C; Derreumaux, S; Chea, M; Cristina, K; Boisserie, G; Bergonzo, P
2013-11-07
Recent developments of new therapy techniques using small photon beams, such as stereotactic radiotherapy, require suitable detectors to determine the delivered dose with a high accuracy. The dosimeter has to be as close as possible to tissue equivalence and to exhibit a small detection volume compared to the size of the irradiation field, because of the lack of lateral electronic equilibrium in small beam. Characteristics of single crystal diamond (tissue equivalent material Z = 6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. A commercially available Element Six electronic grade synthetic diamond was used to develop a single crystal diamond dosimeter (SCDDo) with a small detection volume (0.165 mm(3)). Long term stability was studied by irradiating the SCDDo in a (60)Co beam over 14 h. A good stability (deviation less than ± 0.1%) was observed. Repeatability, dose linearity, dose rate dependence and energy dependence were studied in a 10 × 10 cm(2) beam produced by a Varian Clinac 2100 C linear accelerator. SCDDo lateral dose profile, depth dose curve and output factor (OF) measurements were performed for small photon beams with a micro multileaf collimator m3 (BrainLab) attached to the linac. This study is focused on the comparison of SCDDo measurements to those obtained with different commercially available active detectors: an unshielded silicon diode (PTW 60017), a shielded silicon diode (Sun Nuclear EDGE), a PinPoint ionization chamber (PTW 31014) and two natural diamond detectors (PTW 60003). SCDDo presents an excellent spatial resolution for dose profile measurements, due to its small detection volume. Low energy dependence (variation of 1.2% between 6 and 18 MV photon beam) and low dose rate dependence of the SCDDo (variation of 1% between 0.53 and 2.64 Gy min(-1)) are obtained, explaining the good agreement between the SCDDo and the efficient unshielded diode (PTW 60017) in depth dose curve measurements. For field sizes ranging from 0.6 × 0.6 to 10 × 10 cm(2), OFs obtained with the SCDDo are between the OFs measured with the PinPoint ionization chamber and the Sun Nuclear EDGE diode that are known to respectively underestimate and overestimate OF values in small beam, due to the large detection volume of the chamber and the non-water equivalence of both detectors.
NASA Astrophysics Data System (ADS)
Shurshakov, Vyacheslav; Nikolaev, Igor; Kartsev, Ivan; Tolochek, Raisa; Lyagushin, Vladimir
The tissue-equivalent spherical phantom (32 kg mass, 35 cm diameter and 10 cm central spherical cave) made in Russia has been used on board the ISS in Matroshka-R experiment for more than 10 years. Both passive and active space radiation detectors can be located inside the phantom and on its surface. Due to the specially chosen phantom shape and size, the chord length distributions of the detector locations are attributed to self-shielding properties of the critical organs in a human body. Originally the spherical phantom was installed in the star board crew cabin of the ISS Service Module, then in the Piers-1, MIM-2, and MIM-1 modules of the ISS Russian segment, and finally in JAXA Kibo module. Total duration of the detector exposure is more than 2000 days in 9 sessions of the space experiment. In the first phase of the experiment with the spherical phantom the dose measurements were realized with only passive detectors (thermoluminescent and solid state track detectors). The detectors are placed inside the phantom along the axes of 20 containers and on the phantom outer surface in 32 pockets of the phantom jacket. After each session the passive detectors are returned to the ground. The results obtained show the dose difference on the phantom surface as much as a factor of 2, the highest dose being usually observed close to the outer wall of the compartment, and the lowest dose being in the opposite location along the phantom diameter. However, because of the ISS module shielding properties an inverse dose distribution in a human body can be observed when the dose rate maximum is closer to the geometrical center of the module. Maximum dose rate measured in the phantom is obviously due to the action of two radiation sources, namely, galactic cosmic rays (GCR) and Earth’ radiation belts. Minimum dose rate is produced mainly by the strongly penetrating GCR particles and is mostly observed behind more than 5 g/cm2 tissue shielding. Critical organ doses, mean-tissue and effective doses of a crew member in the ISS compartments are also estimated with the spherical phantom data. The estimated effective dose rate is found to be from 10 % to 15 % lower than the averaged dose on the phantom surface as dependent on the attitude of the critical organs. If compared with the anthropomorphic phantom Rando used inside and outside the ISS earlier, the Matroshka-R space experiment spherical phantom has lower mass, smaller size, and requires less crew time for the detector installation/retrieval; its tissue-equivalent properties are closer to the standard human body tissue than the Rando-phantom material. New sessions with the two tissue-equivalent phantoms are of great interest. Development of modified passive and active detector sets is in progress for the future ISS expeditions. Both the spherical and Rando-type phantoms proved their effectiveness to measure the critical organ doses and effective doses in-flight and if supplied with modernized dosimeters can be recommended for future exploratory manned missions to monitor continuously the crew exposure to space radiation.
Šemeláková, M; Jendželovský, R; Fedoročko, P
2016-07-01
Our previous results have shown that the combination of hypericin-mediated photodynamic therapy (HY-PDT) at sub-optimal dose with hyperforin (HP) (compounds of Hypericum sp.), or its stable derivative aristoforin (AR) stimulates generation of reactive oxygen species (ROS) leading to antitumour activity. This enhanced oxidative stress evoked the need for an explanation for HY accumulation in colon cancer cells pretreated with HP or AR. Generally, the therapeutic efficacy of chemotherapeutics is limited by drug resistance related to the overexpression of drug efflux transporters in tumour cells. Therefore, the impact of non-activated hypericin (HY), HY-PDT, HP and AR on cell membrane transporter systems (Multidrug resistance-associated protein 1-MRP1/ABCC1, Multidrug resistance-associated protein 2-MRP2/ABCC2, Breast cancer resistance protein - BCRP/ABCG2, P-glycoprotein-P-gp/ABCC1) and cytochrome P450 3A4 (CYP3A4) was evaluated. The different effects of the three compounds on their expression, protein level and activity was determined under specific PDT light (T0+, T6+) or dark conditions (T0- T6-). We found that HP or AR treatment affected the protein levels of MRP2 and P-gp, whereas HP decreased MRP2 and P-gp expression mostly in the T0+ and T6+ conditions, while AR decreased MRP2 in T0- and T6+. Moreover, HY-PDT treatment induced the expression of MRP1. Our data demonstrate that HP or AR treatment in light or dark PDT conditions had an inhibitory effect on the activity of individual membrane transport proteins and significantly decreased CYP3A4 activity in HT-29 cells. We found that HP or AR significantly affected intracellular accumulation of HY in HT-29 colon adenocarcinoma cells. These results suggest that HY, HP and AR might affect the efficiency of anti-cancer drugs, through interaction with membrane transporters and CYP3A4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Han, J S
1992-04-01
In experiments designed to determine which active oxygen species contribute to hydrogen peroxide (HP)-induced reversion in strain TA104 of Salmonella typhimurium, 1,10-phenanthroline (an iron chelator, which prevents the formation of hydroxyl radicals from HP and DNA-bound iron by the Fenton reaction), sodium azide (a singlet oxygen scavenger), and potassium iodide (an hydroxyl radical scavenger) inhibited HP-induced reversion. These results indicate that hydroxyl radicals generated from HP by the Fenton reaction, and perhaps singlet oxygen, contribute to HP-induced reversion in TA104. However, reduced glutathione (reduces Fe3+ to Fe2+ and/or HP to water), diethyldithiocarbamic acid (an inhibitor of superoxide dismutase), diethyl maleate (a glutathione scavenger), and 3-amino-1,2,4-triazole (an inhibitor of catalase) did not inhibit HP-induced reversion in TA104. Thus, superoxide radical anions and HP itself do not appear to be the cause of HP-induced reversion in this strain. In experiments on the effect of 5 common dietary compounds (beta-carotene, retinoic acid, and vitamins A, C and E), chlorophyllin (CHL), and ergothioneine, the frequency of revertants in TA104 increased above the spontaneous frequency in the presence of beta-carotene or vitamin C (about 2-fold) or vitamin A (about 3-fold). The 5 dietary antimutagens and CHL did not inhibit HP-induced reversion in TA104. However, L-ergothioneine inhibited HP-induced reversion in this strain. Therefore, it is likely that L-ergothioneine is a scavenger of hydroxyl radicals or an inhibitor of their formation, and perhaps of singlet oxygen, at the concentrations tested in TA104.
Effects of pH values of hydrogen peroxide bleaching agents on enamel surface properties.
Xu, B; Li, Q; Wang, Y
2011-01-01
This study investigated the influence of pH values of bleaching agents on the properties of the enamel surface. Sixty freshly extracted premolars were embedded in epoxy resin and mesiodistally sectioned through the buccal aspect into two parts. The sectioned slabs were distributed among six groups (n=10) and treated using different solutions. Group HCl was treated with HCl solution (pH=3.0) and served as a positive control. Group DW, stored in distilled water (pH=7.0), served as a negative control. Four treatment groups were treated using 30% hydrogen peroxide solutions with different pH values: group HP3 (pH=3.0), group HP5 (pH=5.0), group HP7 (pH=7.0), and group HP8 (pH=8.0). The buccal slabs were subjected to spectrophotometric evaluations. Scanning electron microscopy investigation and Micro-Raman spectroscopy were used to evaluate enamel surface morphological and chemical composition alterations. pH value has a significant influence on the color changes after bleaching (p<0.001). Tukey's multiple comparisons revealed that the order of color changes was HP8, HP7>HP5, HP3>HCl>DW. No obvious morphological alterations were detected on the enamel surface in groups DW, HP7, and HP8. The enamel surface of groups HCl and HP3 showed significant alterations with an erosion appearance. No obvious chemical composition changes were detected with respect to Micro-Raman analysis. Within the limitations of this study, it was concluded that no obvious morphological or chemical composition alterations of enamel surface were detected in the neutral or alkaline bleaching solutions. Bleaching solutions with lower pH values could result in more significant erosion of enamel, which represented a slight whitening effect.
Hydrostatic Pressure–Induced Release of Stored Calcium in Cultured Rat Optic Nerve Head Astrocytes
Mandal, Amritlal; Delamere, Nicholas A.
2010-01-01
Purpose. Elevated intraocular pressure is associated with glaucomatous optic nerve damage. Other investigators have shown functional changes in optic nerve head astrocytes subjected to elevated hydrostatic pressure (HP) for 1 to 5 days. Recently, the authors reported ERK1/2, p90RSK and NHE1 phosphorylation after 2 hours. Here they examine calcium responses at the onset of HP to determine what precedes ERK1/2 phosphorylation. Methods. Cytoplasmic calcium concentration ([Ca2+]i) was measured in cultured rat optic nerve astrocytes loaded with fura-2. The cells were placed in a closed imaging chamber and subjected to an HP increase of 15 mm Hg. Protein phosphorylation was detected by Western blot analysis. Results. The increase of HP caused an immediate slow increase in [Ca2+]i. The response persisted in calcium-free solution and when nickel chloride (4 mM) was added to suppress channel-mediated calcium entry. Previous depletion of the ER calcium stores by cyclopiazonic acid abolished the HP-induced calcium level increase. The HP-induced increase persisted in cells exposed to xestospongin C, an inhibitor of IP3R-mediated calcium release. In contrast, ryanodine receptor (RyR) antagonist ruthenium red (10 μM) or dantrolene (25 μM) inhibited the HP-induced calcium increase. The HP-induced calcium increase was abolished when ryanodine-sensitive calcium stores were pre-depleted with caffeine (3 mM). HP caused ERK1/2 phosphorylation. The magnitude of the ERK1/2 phosphorylation response was reduced by ruthenium red and dantrolene. Conclusions. Increasing HP causes calcium release from a ryanodine-sensitive cytoplasmic store and subsequent ERK1/2 activation. Calcium store release appears to be a required early step in the initial astrocyte response to an HP increase. PMID:20071675
Helicobacter pylori HP1512 Is a Nickel-Responsive NikR-Regulated Outer Membrane Protein▿
Davis, Gregg S.; Flannery, Erika L.; Mobley, Harry L. T.
2006-01-01
Helicobacter pylori is dependent upon the production of the highly abundant and active metalloenzyme urease for colonization of the human stomach. Thus, H. pylori has an absolute requirement for the transition metal nickel, a required cofactor for urease. To investigate the contribution of genes that are factors in this process, microarray analysis comparing the transcriptome of wild-type H. pylori 26695 cultured in brucella broth containing fetal calf serum (BBF) alone or supplemented with 100 μM NiCl2 suggested that HP1512 is repressed in the presence of 100 μM supplemental nickel. When measured by comparative real-time quantitative PCR (qPCR), HP1512 transcription was reduced 43-fold relative to the value for the wild type when cultured in BBF supplemented with 10 μM NiCl2. When grown in unsupplemented BBF, urease activity of an HP1512::cat mutant was significantly reduced compared to the wild type, 4.9 ± 0.5 μmol/min/mg of protein (n = 7) and 17.1 ± 4.9 μmol/min/mg of protein (n = 13), respectively (P < 0.0001). In silico analysis of the HP1511-HP1512 (HP1511-1512) intergenic region identified a putative NikR operator upstream of HP1512. Gel shift analysis with purified recombinant NikR verified nickel-dependent binding of H. pylori NikR to the HP1511-1512 intergenic region. Furthermore, comparative real-time qPCR of four nickel-related genes suggests that mutation of HP1512 results in reduced intracellular nickel concentration relative to wild-type H. pylori 26695. Taken together, these data suggest that HP1512 encodes a NikR-nickel-regulated outer membrane protein. PMID:17030579
Tsuda, Shuichi; Sato, Tatsuhiko; Takahashi, Fumiaki; Satoh, Daiki; Endo, Akira; Sasaki, Shinichi; Namito, Yoshihito; Iwase, Hiroshi; Ban, Shuichi; Takada, Masashi
2010-09-07
The frequency distribution of the lineal energy, y, of a 290 MeV/u carbon beam was measured to obtain the dose-weighted mean of y and compare it with the linear energy transfer (LET). In the experiment, a wall-less tissue-equivalent proportional counter (TEPC) in a cylindrical volume with a simulated diameter of 0.72 microm was used. The measured frequency distribution of y as well as its dose-mean value agrees within 10% uncertainty with the corresponding data from microdosimetric calculations using the PHITS code. The ratio of the measured dose-mean lineal energy to the LET of the 290 MeV/u carbon beam is 0.73, which is much smaller than the corresponding data obtained by a wall TEPC. This result demonstrates that a wall-less TEPC is necessary to precisely measure the dose-mean of y for energetic heavy ion beams.
3DHZETRN: Inhomogeneous Geometry Issues
NASA Technical Reports Server (NTRS)
Wilson, John W.; Slaba, Tony C.; Badavi, Francis F.
2017-01-01
Historical methods for assessing radiation exposure inside complicated geometries for space applications were limited by computational constraints and lack of knowledge associated with nuclear processes occurring over a broad range of particles and energies. Various methods were developed and utilized to simplify geometric representations and enable coupling with simplified but efficient particle transport codes. Recent transport code development efforts, leading to 3DHZETRN, now enable such approximate methods to be carefully assessed to determine if past exposure analyses and validation efforts based on those approximate methods need to be revisited. In this work, historical methods of representing inhomogeneous spacecraft geometry for radiation protection analysis are first reviewed. Two inhomogeneous geometry cases, previously studied with 3DHZETRN and Monte Carlo codes, are considered with various levels of geometric approximation. Fluence, dose, and dose equivalent values are computed in all cases and compared. It is found that although these historical geometry approximations can induce large errors in neutron fluences up to 100 MeV, errors on dose and dose equivalent are modest (<10%) for the cases studied here.
Interaction of Bacterial Phenazines with Colistimethate in Bronchial Epithelial Cells.
Mossine, Valeri V; Chance, Deborah L; Waters, James K; Mawhinney, Thomas P
2018-05-21
Multidrug-resistant bacterial infections are being increasingly treated in clinics with polymyxins, a class of antibiotics associated with adverse effects in the kidney, nervous system, or airways of a significant proportion of human and animal patients. Although many of the resistant pathogens display enhanced virulence, a hazard of cytotoxic interactions between polymyxin antibiotics and bacterial virulence factors (VFs) has not been assessed, to date. We report here on testing paired combinations of four Pseudomonas aeruginosa VF phenazine toxins, pyocyanin (PYO), 1-hydroxyphenazine (1-HP), phenazine-1-carboxylic acid (PCA), phenazine-1-carboxamide (PCN), and two commonly prescribed polymyxin drugs, colistimethate (CMS)/colistin and polymyxin B, in three human airway cell lines, BEAS-2B, HBE-1, and CFT-1. Cytotoxicities of individual antibiotics, toxins, and their combinations were evaluated by simultaneous measurement of mitochondrial metabolic, total transcriptional/translational, and the Nrf2 stress response regulator activities in treated cells. Two phenazines, PYO and 1-HP, were cytotoxic at clinically relevant concentrations (100-150 μM) and prompted a significant increase in the oxidative stress-induced transcriptional activity in surviving cells. The polymyxin antibiotics arrested the cell proliferation at clinically achievable (< 1 mM) concentrations, as well, with CMS displaying a surprisingly high cytotoxicity (ED 50 = 180 μM) in BEAS-2B. The dose-response curves were probed by the median-effect analysis which established a synergistically enhanced cytotoxicity of the PYO/CMS combination in all three airway cell lines; a particularly strong effect was observed in the BEAS-2B cells, with the combination index (CI) = 0.27 at ED 50 PCA, PCN, and 1-HP potentiated CMS cytotoxicity to a smaller extent. The cytotoxicity of CMS could be reduced with 10 mM N -acetyl-cysteine. Iron chelators, while ineffective against the polymyxins, could rescue all three bronchial epithelial cell lines treated with lethal PYO or CMS/PYO doses. These findings suggest further evaluations of CMS safety are needed, along with a search for means to moderate the potentially cytotoxic interactions. Copyright © 2018 Mossine et al.
Cengiz, Esra; Kurtulmus-Yilmaz, Sevcan; Ulusoy, Nuran; Deniz, Sule Tugba; Yuksel-Devrim, Ece
2016-05-01
The aim of this study was to investigate the effect of hydrogen peroxide (HP) and carbamide peroxide (CP) on the surface roughness of five different composite resins using profilometer and scanning electron microscope (SEM). Thirty-six specimens (1 mm thick, 10 mm in diameter) of five composite resins were fabricated. Each composite group was equally divided into three subgroups as control, CP and HP. In control group, specimens were stored in daily refreshed distilled water during the 14-day testing period. In other groups, 10% HP (Opalescence Treswhite) and 10% CP (Opalescence PF) were applied and surface roughness values (Ra) of each specimen were measured with a profilometer at the end of 14 days. Additionally, SEM analysis was performed to evaluate the surface deformations of composite resins. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests. Ra values of composite groups exposed to bleaching agents were statistically higher than control group (p < 0.05). There was no significant difference between Ra values after HP and CP application within each composite group while SEM micrographs showed higher surface alterations at HP group compared to CP. Among the composite resins tested, Ceram-X Mono revealed the lowest Ra values after CP and HP applications as seen at SEM images. Home bleaching agents increased the surface roughness of all composites. Except CP applied Ceram-X mono specimens, Ra values of all composite resins evaluated in this study exceeded the critical limit of 0.2 μm. Ceram-X mono was the least affected composite material after bleaching application. SCANNING 38:277-283, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carl, W. F.
NASA Langley Research Center requested a measurement and determination of the ambient gamma dose equivalent rate and kerma at 100 cm from the 252Cf source and determination of the ambient gamma dose equivalent rate and kerma at 200 cm from the 60Co source for the Radiation Budget Instrument Experiment (Rad-X). An Exradin A6 ion chamber with Shonka air-equivalent plastic walls in combination with a Supermax electrometer were used to measure the exposure rate and free-in-air kerma rate of the two sources at the requested distances. The measured gamma exposure, kerma, and dose equivalent rates are tabulated.
Energy balance and hypothalamic effects of a high-protein/low-carbohydrate diet.
Kinzig, Kimberly P; Hargrave, Sara L; Hyun, Jayson; Moran, Timothy H
2007-10-22
Diets high in fat or protein and extremely low in carbohydrate are frequently reported to result in weight loss in humans. We previously reported that rats maintained on a low-carbohydrate-high fat diet (LC-HF) consumed similar kcals/day as chow (CH)-fed rats and did not differ in body weight after 7 weeks. LC-HF rats had a 45% decrease in POMC expression in the ARC, decreased plasma insulin, and increased plasma leptin and ghrelin. In the present study we assessed the effects of a low-carbohydrate-high-protein diet (HP: 30% fat, 65% protein, and 5% CHO) on body weight, caloric intake, plasma hormone levels and hypothalamic gene expression. Male rats (n=16) were maintained on CH or HP for 4 weeks. HP rats gained significantly less weight than CH rats (73.4+/-9.4 and 125.0+/-8.2 g) and consumed significantly less kcals/day (94.8+/-1.5 and 123.6+/-1.1). Insulin was significantly reduced in HP rats (HP: 1.8+/-0.6 vs. CH: 4.12+/-0.8 ng/ml), there were no differences between groups in plasma leptin and plasma ghrelin was significantly elevated in HP rats (HP: 127.5+/-45 vs. CH: 76.9+/-8 pg/ml). Maintenance on HP resulted in significantly increased ARC POMC (HP: 121+/-10.0 vs. 100+/-5.9) and DMH NPY (HP: 297+/-82.1 vs. CH: 100+/-37.7) expression compared to CH controls. These data suggest that the macronutrient content of diets differentially influences hypothalamic gene expression in ways that can affect overall intake.
Schneider, Christopher; Newhauser, Wayne; Farah, Jad
2015-05-18
Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation.
Moslehi, A; Raisali, G; Lamehi, M
2017-04-15
To find appropriate substitutions for the expensive plastics of A-150 and rexolite used in the construction of thick gas electron multiplier (THGEM)-based tissue-equivalent proportional counters, in the present work, the responses of a THGEM-based microdosimetric detector made of A-150 and rexolite and three others composed of plexiglas (PMMA), polyethylene and polystyrene plastics as the wall materials have been compared. Lineal energy distribution, frequency-averaged lineal energy, dose-averaged lineal energy, mean quality factor and dose-equivalent for 0.1, 1 and 10 MeV neutrons and also for 241Am-Be neutrons are calculated using Geant4 simulation toolkit. Frequency-averaged lineal energy, dose-averaged lineal energy, mean quality factor and dose-equivalent values for all plastics are found similar. In addition, the response of an indigenously constructed microdosemeter with PMMA walls is also measured for 241Am-Be neutrons. The experimental results are in good agreement with the simulation predictions. Conclusively, it was found that the three considered plastics can be used as good candidates instead of A-150 and rexolite plastics in fast neutron microdosimetry. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Al Najjar, Anas; Colosi, Dan; Dauer, Lawrence T; Prins, Robert; Patchell, Gayle; Branets, Iryna; Goren, Arthur D; Faber, Richard D
2013-06-01
With the advent of cone-beam computed tomography (CBCT) scans, there has been a transition toward these scans' replacing traditional radiographs for orthodontic diagnosis and treatment planning. Children represent a significant proportion of orthodontic patients. Similar CBCT exposure settings are predicted to result in higher equivalent doses to the head and neck organs in children than in adults. The purpose of this study was to measure the difference in equivalent organ doses from different scanners under similar settings in children compared with adults. Two phantom heads were used, representing a 33-year-old woman and a 5-year-old boy. Optically stimulated dosimeters were placed at 8 key head and neck organs, and equivalent doses to these organs were calculated after scanning. The manufacturers' predefined exposure settings were used. One scanner had a pediatric preset option; the other did not. Scanning the child's phantom head with the adult settings resulted in significantly higher equivalent radiation doses to children compared with adults, ranging from a 117% average ratio of equivalent dose to 341%. Readings at the cervical spine level were decreased significantly, down to 30% of the adult equivalent dose. When the pediatric preset was used for the scans, there was a decrease in the ratio of equivalent dose to the child mandible and thyroid. CBCT scans with adult settings on both phantom heads resulted in higher radiation doses to the head and neck organs in the child compared with the adult. In practice, this might result in excessive radiation to children scanned with default adult settings. Collimation should be used when possible to reduce the radiation dose to the patient. While CBCT scans offer a valuable tool, use of CBCT scans should be justified on a specific case-by-case basis. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.
Hu, Panpan; Kong, Yan; Chen, Bo; Liu, Qianqian; Zhuo, Weihai; Liu, Haikuan
2017-04-20
To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm2 per glass) lens are recommended. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Radiation tolerance of readout electronics for Belle II
NASA Astrophysics Data System (ADS)
Higuchi, T.; Nakao, M.; Nakano, E.
2012-02-01
We plan to start the Belle II experiment in 2015 and to continue data taking for more than ten years. Because some of the front-end electronics cards of Belle II are located inside the detector, radiation effects onto their components will be a severe problem. Using experimental exposure facilities of neutrons and γ rays, we study the radiation effects from these particles to the Virtex-5 FPGA, optical transceivers, and voltage regulators. The Virtex-5 FPGA is found to keep its operation after irradiation of more than 20-year-equivalent neutron flux of Belle II and 88-year-equivalent γ-ray dose. We observe single event upsets (SEUs) and multiple bit upsets (MBUs) in the Virtex-5 FPGA in the neutron irradiation. We also find almost doubled SEU counts in the Virtex-5 FPGA bombarded from its tail side than its head side. We extrapolate the observed SEU and MBU counts in the Virtex-5 FPGA to the entire readout system of the Belle II central drift chamber, and expect the SEU and MBU rates as one SEU per four minutes and one MBU per 11.5 hours, respectively. The optical transceivers are found to keep its operation after integration of 12-year-equivalent neutron flux, while they are killed by about 3-year-equivalent γ-ray dose, which should be solved in the future research. The voltage regulators are found to keep its operation for more than 10-year-equivalent γ-ray dose.
Experimental search for hidden photon CDM in the eV mass range with a dish antenna
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, J.; Horie, T.; Minowa, M.
2015-09-01
A search for hidden photon cold dark matter (HP CDM) using a new technique with a dish antenna is reported. From the result of the measurement, we found no evidence for the existence of HP CDM and set an upper limit on the photon-HP mixing parameter χ of ∼ 6× 10{sup −12} for the hidden photon mass m{sub γ} = 3.1 ± 1.2 eV.
Code of Federal Regulations, 2014 CFR
2014-07-01
...-2007 Model Year Engines With a Displacement of 1 Table 1 to Subpart IIII of Part 60 Protection of... Stationary Pre-2007 Model Year Engines With a Displacement of 2,237 KW (3,000 HP) and With a Displacement of 2,237 KW (3,000 HP) and with a displacement of 560 (HP>750) 1.3 (1.0) 9.2 (6.9) 11.4 (8.5) 0.54 (0...
Code of Federal Regulations, 2012 CFR
2012-07-01
...-2007 Model Year Engines With a Displacement of 1 Table 1 to Subpart IIII of Part 60 Protection of... Stationary Pre-2007 Model Year Engines With a Displacement of 2,237 KW (3,000 HP) and With a Displacement of 2,237 KW (3,000 HP) and with a displacement of 560 (HP>750) 1.3 (1.0) 9.2 (6.9) 11.4 (8.5) 0.54 (0...
Code of Federal Regulations, 2013 CFR
2013-07-01
...-2007 Model Year Engines With a Displacement of 1 Table 1 to Subpart IIII of Part 60 Protection of... Stationary Pre-2007 Model Year Engines With a Displacement of 2,237 KW (3,000 HP) and With a Displacement of 2,237 KW (3,000 HP) and with a displacement of 560 (HP>750) 1.3 (1.0) 9.2 (6.9) 11.4 (8.5) 0.54 (0...
Code of Federal Regulations, 2010 CFR
2010-07-01
...-2007 Model Year Engines With a Displacement of 1 Table 1 to Subpart IIII of Part 60 Protection of... Stationary Pre-2007 Model Year Engines With a Displacement of 2,237 KW (3,000 HP) and With a Displacement of 2,237 KW (3,000 HP) and with a displacement of 560 (HP>750) 1.3 (1.0) 9.2 (6.9) 11.4 (8.5) 0.54 (0...
Code of Federal Regulations, 2011 CFR
2011-07-01
...-2007 Model Year Engines With a Displacement of 1 Table 1 to Subpart IIII of Part 60 Protection of... Stationary Pre-2007 Model Year Engines With a Displacement of 2,237 KW (3,000 HP) and With a Displacement of 2,237 KW (3,000 HP) and with a displacement of 560 (HP>750) 1.3 (1.0) 9.2 (6.9) 11.4 (8.5) 0.54 (0...
Absorbed Dose and Dose Equivalent Calculations for Modeling Effective Dose
NASA Technical Reports Server (NTRS)
Welton, Andrew; Lee, Kerry
2010-01-01
While in orbit, Astronauts are exposed to a much higher dose of ionizing radiation than when on the ground. It is important to model how shielding designs on spacecraft reduce radiation effective dose pre-flight, and determine whether or not a danger to humans is presented. However, in order to calculate effective dose, dose equivalent calculations are needed. Dose equivalent takes into account an absorbed dose of radiation and the biological effectiveness of ionizing radiation. This is important in preventing long-term, stochastic radiation effects in humans spending time in space. Monte carlo simulations run with the particle transport code FLUKA, give absorbed and equivalent dose data for relevant shielding. The shielding geometry used in the dose calculations is a layered slab design, consisting of aluminum, polyethylene, and water. Water is used to simulate the soft tissues that compose the human body. The results obtained will provide information on how the shielding performs with many thicknesses of each material in the slab. This allows them to be directly applicable to modern spacecraft shielding geometries.
Recent Progress in the p and h-p Version of the Finite Element Method.
1987-07-01
code PROBE which was developed recently by NOETIC Technologies, St. Louis £54]. PROBE solves two dimensional problems of linear elasticity, stationary...of the finite element method was studied in detail from various point of view. We will mention here some essential illustrative results. In one...28) Bathe, K. J., Brezzi, F., Studies of finite element procedures - the INF-SUP condition, equivalent forms and applications in Reliability of
NASA Astrophysics Data System (ADS)
Shurshakov, Vyacheslav; Akatov, Yu; Petrov, V.; Kartsev, I.; Polenov, Boris; Petrov, V.; Lyagushin, V.
In the space experiment MATROSHKA-R, the spherical tissue equivalent phantom (30 kg mass, 35 cm diameter and 10 cm central spherical cave) made in Russia has been installed in the star board crew cabin of the ISS Service Module. Due to the specially chosen phantom shape and size, the chord length distributions of the detector locations are attributed to self-shielding properties of the critical organs in a real human body. If compared with the anthropomorphic phantom Rando used inside and outside the ISS, the spherical phantom has lower mass, smaller size, and requires less crew time for the detector retrieval; its tissue-equivalent properties are closer to the standard human body tissue than the Rando-phantom material. In the first phase of the experiment the dose measurements were realized with only passive detectors (thermoluminescent and solid state track detectors). There were two experimental sessions with the spherical phantom in the crew cabin, (1) from Jan. 29, 2004 to Apr. 30, 2004 and (2) from Aug. 11, 2004 to Oct. 10, 2005. The detectors are placed inside the phantom along the axes of 20 containers and on the phantom outer surface in 32 pockets of the phantom jacket. The results obtained with the passive detectors returned to the ground after each session show the dose difference on the phantom surface as much as a factor of 2, the highest dose being observed close to the outer wall of the crew cabin, and the lowest dose being in the opposite location along the phantom diameter. Maximum dose rate measured in the phantom (0.31 mGy/day) is obviously due to the galactic cosmic ray (GCR) and Earth' radiation belt contribution on the ISS trajectory. Minimum dose rate (0.15 mGy/day) is caused mainly by the strongly penetrating GCR particles and is observed behind more than 5 g/cm2 tissue shielding. Critical organ doses, mean-tissue and effective doses of a crew member in the crew cabin are also estimated with the spherical phantom. The estimated effective dose rate (about 0.49 mSv/day at radiation quality factor of 2.6) is from 12 to 15 per cent lower than the averaged dose on the phantom surface as dependent on the body attitude.
Ogawa, Rei; Orgill, Dennis P; Murphy, George F; Mizuno, Shuichi
2015-01-01
The chondrogenic potential of adipose-derived stem cells (ASCs) has been previously demonstrated, although several reports have indicated that ASCs produce less cartilage-specific matrix than bone marrow-derived mesenchymal stem cells. In this study, we intended to improve chondrogenic phenotypes of ASCs using hydrostatic pressure (HP), without utilizing any growth factors other than the transforming growth factor-β1. Human ASCs (CD13(+), 44(+), 90(+), 14(-), 31(-), 34(-)) were harvested and cultured. After three passages, the cells were suspended in 0.3% neutralized collagen type I solution and injected into semipermeable membrane tubes, from which 66 pouches were constructed. After a day of incubation, the 66 pouches were divided into three groups. Group HP1: Pouches were incubated for 1 week with treatment of cyclic HP at 0-0.5 MPa (4.93 atm), 0.5 Hz, with a medium replenishment rate of 0.1 mL/min at 37°C, 3% O2, and 5% CO2 in air using a bioprocessor. This was followed by 3 weeks with no HP and without pouches. Group HP2: Pouches were incubated for the first and third week (2 total weeks) with the same condition of Group HP1. No HP was applied in the second and fourth week. Group AP: Pouches with one end opened were incubated without HP. We evaluated the cell constructs histologically and immunohistochemically, as well as for specific gene expression. Accumulation of the matrix in the HP1 and HP2 groups was much denser than AP groups, particularly after 2 weeks. Cell numbers in the HP groups increased gradually in the middle zone and peaked at 1 week after incubation, maintaining their numbers for the entire course on the surface layer of the construct. In the genomic study results, COL 2A1, COL 10A1, ACAN, SOX9, MMP3, and MMP13 were upregulated and COL 1A1, ITGB1, and PCNA were downregulated by HP. There were no significant differences between HP1 and HP2 gene expression. It was suggested that HP is especially beneficial in the early stage of chondrogenesis of ASCs. Moreover, the expression profile of genes related to chondrocyte differentiation/proliferation was significantly enhanced by HP loading compared with the AP control.
NASA Astrophysics Data System (ADS)
Xu, Shengsheng; Kaltashov, Igor A.
2016-12-01
Haptoglobin (Hp) is a plasma glycoprotein that generates significant interest in the drug delivery community because of its potential for delivery of antiretroviral medicines with high selectivity to macrophages and monocytes, the latent reservoirs of human immunodeficiency virus. As is the case with other therapies that exploit transport networks for targeted drug delivery, the success of the design and optimization of Hp-based therapies will critically depend on the ability to accurately localize and quantitate Hp-drug conjugates on the varying and unpredictable background of endogenous proteins having identical structure. In this work, we introduce a new strategy for detecting and quantitating exogenous Hp and Hp-based drugs with high sensitivity in complex biological samples using gallium as a tracer of this protein and inductively coupled plasma mass spectrometry (ICP MS) as a method of detection. Metal label is introduced by reconstituting hemoglobin (Hb) with gallium(III)-protoporphyrin IX followed by its complexation with Hp. Formation of the Hp/Hb assembly and its stability are evaluated with native electrospray ionization mass spectrometry. Both stable isotopes of Ga give rise to an abundant signal in ICP MS of a human plasma sample spiked with the metal-labeled Hp/Hb complex. The metal label signal exceeds the spectral interferences' contributions by more than an order of magnitude even with the concentration of the exogenous protein below 10 nM, the level that is more than adequate for the planned pharmacokinetic studies of Hp-based therapeutics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omari, Eenas A.; Erickson, Beth; Noid, George
Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures weremore » contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an ultrasound image, the portal vein is identified as a surrogate. The authors have demonstrated the feasibility of tracking HP motion through the localization of the PV using TAUS. This will potentially allow real-time tracking of intrafractional motion to justify small PTV-margins and to account for unusual motions, thus, improving normal tissue sparing.« less
Space Radiation Organ Doses for Astronauts on Past and Future Missions
NASA Technical Reports Server (NTRS)
Cucinotta, Francis A.
2007-01-01
We review methods and data used for determining astronaut organ dose equivalents on past space missions including Apollo, Skylab, Space Shuttle, NASA-Mir, and International Space Station (ISS). Expectations for future lunar missions are also described. Physical measurements of space radiation include the absorbed dose, dose equivalent, and linear energy transfer (LET) spectra, or a related quantity, the lineal energy (y) spectra that is measured by a tissue equivalent proportional counter (TEPC). These data are used in conjunction with space radiation transport models to project organ specific doses used in cancer and other risk projection models. Biodosimetry data from Mir, STS, and ISS missions provide an alternative estimate of organ dose equivalents based on chromosome aberrations. The physical environments inside spacecraft are currently well understood with errors in organ dose projections estimated as less than plus or minus 15%, however understanding the biological risks from space radiation remains a difficult problem because of the many radiation types including protons, heavy ions, and secondary neutrons for which there are no human data to estimate risks. The accuracy of projections of organ dose equivalents described here must be supplemented with research on the health risks of space exposure to properly assess crew safety for exploration missions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Requirements to qualify for an STCW endorsement as electro-technical rating (ETR) on vessels powered by main propulsion machinery of 750 kW/1,000 HP or more... propulsion machinery of 750 kW/1,000 HP or more. (a) To qualify for an STCW endorsement as an electro...
Calculation of Radiation Protection Quantities and Analysis of Astronaut Orientation Dependence
NASA Technical Reports Server (NTRS)
Clowdsley, Martha S.; Nealy, John E.; Atwell, William; Anderson, Brooke M.; Luetke, Nathan J.; Wilson, John W.
2006-01-01
Health risk to astronauts due to exposure to ionizing radiation is a primary concern for exploration missions and may become the limiting factor for long duration missions. Methodologies for evaluating this risk in terms of radiation protection quantities such as dose, dose equivalent, gray equivalent, and effective dose are described. Environment models (galactic cosmic ray and solar particle event), vehicle/habitat geometry models, human geometry models, and transport codes are discussed and sample calculations for possible lunar and Mars missions are used as demonstrations. The dependence of astronaut health risk, in terms of dosimetric quantities, on astronaut orientation within a habitat is also examined. Previous work using a space station type module exposed to a proton spectrum modeling the October 1989 solar particle event showed that reorienting the astronaut within the module could change the calculated dose equivalent by a factor of two or more. Here the dose equivalent to various body tissues and the whole body effective dose due to both galactic cosmic rays and a solar particle event are calculated for a male astronaut in two different orientations, vertical and horizontal, in a representative lunar habitat. These calculations also show that the dose equivalent at some body locations resulting from a solar particle event can vary by a factor of two or more, but that the dose equivalent due to galactic cosmic rays has a much smaller (<15%) dependence on astronaut orientation.
A comparison of two methods of in vivo dosimetry for a high energy neutron beam.
Blake, S W; Bonnett, D E; Finch, J
1990-06-01
Two methods of in vivo dosimetry have been compared in a high energy neutron beam. These were activation dosimetry and thermoluminescence dosimetry (TLD). Their suitability was determined by comparison with estimates of total dose, obtained using a tissue equivalent ionization chamber. Measurements were made on the central axis and a profile of a 10 x 10 cm square field and also behind a shielding block in order to simulate conditions of clinical use. The TLD system was found to provide the best estimate of total dose.
Ripken, Dina; van Avesaat, Mark; Troost, Freddy J; Masclee, Ad A; Witkamp, Renger F; Hendriks, Henk F
2017-02-01
Activation of the ileal brake by casein induces satiety signals and reduces energy intake. However, adverse effects of intraileal casein administration have not been studied before. These adverse effects may include impaired amino acid digestion, absorption and immune activation. To investigate the effects of intraileal infusion of native casein on plasma amino acid appearance, immune activation and gastrointestinal (GI) symptoms. A randomized single-blind cross over study was performed in 13 healthy subjects (6 male; mean age 26 ± 2.9 years; mean body mass index 22.8 ± 0.4 kg/m -2 ), who were intubated with a naso-ileal feeding catheter. Thirty minutes after intake of a standardized breakfast, participants received an ileal infusion, containing either control (C) consisting of saline, a low-dose (17.2 kcal) casein (LP) or a high-dose (51.7 kcal) of casein (HP) over a period of 90 min. Blood samples were collected for analysis of amino acids (AAs), C-reactive protein (CRP), pro-inflammatory cytokines and oxylipins at regular intervals. Furthermore, GI symptom questionnaires were collected before, during and after ileal infusion. None of the subjects reported any GI symptoms before, during or after ileal infusion of C, LP and HP. Plasma concentrations of all AAs analyzed were significantly increased after infusion of HP as compared to C (p < 0.001), and most AAs were increased after infusion of LP (p < 0.001). In total, 12.49 ± 1.73 and 3.18 ± 0.87 g AAs were found in plasma after intraileal infusion of HP and LP, corresponding to 93 ± 13% (HP) and 72 ± 20% (LP) of AAs infused as casein, respectively. Ileal casein infusion did not affect plasma concentrations of CRP, IL-6, IL-8, IL-1β and TNF-α. Infusion of HP resulted in a decreased concentration of 11,12-dihydroxyeicosatrienoic acid whereas none of the other oxylipins analyzed were affected. A single intraileal infusion of native casein results in a concentration and time dependent increase of AAs in plasma, suggesting an effective digestion and absorption of AAs present in casein. Also, ileal infusion did not result in immune activation nor in GI symptoms. CLINICALTRIALS.GOV: NCT01509469. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Lima, Suellen Nogueira Linares; Ribeiro, Izabella Santos; Grisotto, Marcos Augusto; Fernandes, Elizabeth Soares; Hass, Viviane; de Jesus Tavarez, Rudys Rodolfo; Pinto, Shelon Cristina Souza; Lima, Darlon Martins; Loguercio, Alessandro D; Bandeca, Matheus Coelho
2018-01-01
This randomized double-blind clinical trial compared tooth sensitivity (TS), bleaching efficacy, and cytokine levels after applying in-office bleaching treatments containing 15% and 35% hydrogen peroxide (HP15% and HP35%, respectively). Twenty-five volunteers were randomly assigned to receive HP15% or HP35% treatment. The bleaching agent was applied in three 15-min applications per session. Two bleaching sessions were separated by a 1-week interval. The participants scored TS using a visual analog scale and numerical rating scale. Bleaching efficacy was determined by subjective and objective methods. Gingival crevicular fluid was collected from three jaws sites per patient for the analysis of fluid volume. Flow cytometry was used to analyze gingival crevicular fluid levels of interleukin (IL)-1β, IL-2, IL-4, IL-6, IL-10, tumor necrosis factor, and interferon-gamma. All measurements were obtained before and after bleaching. All data were statistically analyzed (α=0.05). The absolute risk and intensity of TS was higher for HP35% than for HP15% (p>0.002). One month post-bleaching, HP35% produced more bleaching than HP15% (p=0.02). However patient perception (p=0.06) and patient satisfaction (p=0.53) with regard to bleaching were not significantly different. No significant differences existed in the gingival fluid volume (p>0.38) or in any cytokine level (p>0.05) for either HP concentration. Treatment: with HP35% is more effective than HP15%, but generates a greater risk and intensity of TS. No inflammatory changes occurred despite the difference in the HP concentrations. Hydrogen peroxide at a lower concentration (e.g., 15%) should be considered a good treatment alternative for in-office bleaching because the higher concentration for in-office bleaching generates a greater risk and intensity of TS for patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Moro, Francesca; Scarinci, Elisa; Palla, Carola; Romani, Federica; Familiari, Alessandra; Tropea, Anna; Leoncini, Emanuele; Lanzone, Antonio; Apa, Rosanna
2015-01-01
Is the treatment with recombinant FSH (rFSH) plus recombinant LH (rLH) more effective than highly purified (HP)-hMG in terms of ongoing pregnancy rate (PR) in women ≥35 years of age undergoing intrauterine insemination (IUI) cycles? The ongoing PR was not significantly different in women treated with rFSH plus rLH or with HP-hMG. Although previous studies have shown beneficial effects of the addition of LH activity to FSH, in terms of PR in patients aged over 34 years having ovulation induction, no studies have compared two different gonadotrophin preparations containing LH activity in women ≥35 years of age in IUI cycles. A single-centre RCT was performed between May 2012 and September 2013 with 579 women ≥35 years of age undergoing IUI cycles. The patients were randomly assigned to one of the two groups, rFSH in combination with rLH group or HP-hMG (Meropur) group, by giving them a code number from a computer generated randomization list, in order of enrolment. The randomization visit took place on the first day of ovarian stimulation. Five hundred and seventy-nine patients with unexplained infertility or mild male factor undergoing IUI cycles were recruited in a university hospital setting. All women were enrolled in this study only for one cycle of treatment. Five hundred and seventy-nine cycles were included in the final analysis. Two hundred and ninety patients were treated with rFSH in combination with rLH and 289 patients were treated with HP-hMG. The ovarian stimulation cycle started on the third day of the menstrual cycle and the starting gonadotrophin doses used were 150 IU/day of rFSH plus 150 IU/day of rLH or 150 IU/day of HP-hMG. The drug dose was adjusted according to the individual follicular response. A single IUI per cycle was performed 34-36 h after hCG injection. The main outcome measures were ongoing PR and number of interrupted cycles for high risk of ovarian hyperstimulation syndrome (OHSS). Ongoing pregnancy rates were 48/290 (17.3%) in the recombinant group versus 35/289 (12.2%) in the HP-hMG group [(odds ratio (OR) 1.50, 95% CI 0.94-2.41, P = 0.09]. The number of interrupted cycles for high risk of OHSS was 13/290 (4.5%) in the rFSH plus rLH group and 2/289 (0.7%) in the HP-hMG group (OR 6.73, 95% CI 1.51-30.12, P = 0.013). One of the limitations of this study was the early closure and the ongoing PR could be overestimated. Both patient and gynaecologist were informed of the assigned treatment. Our results demonstrated the lack of differences in terms of ongoing PR between recombinant product and HP-hMG, in women ≥35 years undergoing controlled ovarian stimulation for IUI cycles. HP-hMG was safer than recombinant gonadotrophin concerning the risk of OHSS. None. NCT01604044. © The Author 2014. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Effective dose equivalent on the ninth Shuttle--Mir mission (STS-91)
NASA Technical Reports Server (NTRS)
Yasuda, H.; Badhwar, G. D.; Komiyama, T.; Fujitaka, K.
2000-01-01
Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).
Relative Impact of Incorporating Pharmacokinetics on ...
The use of high-throughput in vitro assays has been proposed to play a significant role in the future of toxicity testing. In this study, rat hepatic metabolic clearance and plasma protein binding were measured for 59 ToxCast phase I chemicals. Computational in vitro-to-in vivo extrapolation was used to estimate the daily dose in a rat, called the oral equivalent dose, which would result in steady-state in vivo blood concentrations equivalent to the AC50 or lowest effective concentration (LEC) across more than 600 ToxCast phase I in vitro assays. Statistical classification analysis was performed using either oral equivalent doses or unadjusted AC50/LEC values for the in vitro assays to predict the in vivo effects of the 59 chemicals. Adjusting the in vitro assays for pharmacokinetics did not improve the ability to predict in vivo effects as either a discrete (yes or no) response or a low effect level (LEL) on a continuous dose scale. Interestingly, a comparison of the in vitro assay with the lowest oral equivalent dose with the in vivo endpoint with the lowest LEL suggested that the lowest oral equivalent dose may provide a conservative estimate of the point of departure for a chemical in a dose-response assessment. Furthermore, comparing the oral equivalent doses for the in vitro assays with the in vivo dose range that resulted in adverse effects identified more coincident in vitro assays across chemicals than expected by chance, suggesting that the approach ma
Effect of 10% Strontium Chloride and 5% Potassium Nitrate with Fluoride on Bleached Bovine Enamel.
Alencar, Cristiane de Melo; Pedrinha, Victor Feliz; Araújo, Jesuína Lamartine Nogueira; Esteves, Renata Antunes; Silva da Silveira, Ana Daniela; Silva, Cecy Martins
2017-01-01
Dental whitening has been increasingly sought out to improve dental aesthetics, but may cause chemical and morphological changes in dental enamel surfaces. This study evaluated in vitro the effect of 10% strontium chloride and 5% potassium nitrate with fluoride on bovine enamel, through tristimulus colorimetry, Knoop microhardness (KHN), and roughness after bleaching with 35% hydrogen peroxide (HP). The specimens were divided into three groups (n=15): GControl received bleaching treatment with 35% HP; GNitrate received bleaching with 35% HP followed by the application of 5% potassium nitrate with 2% sodium fluoride; and GStrontium received bleaching with 35% HP followed by the application of 10% strontium chloride on the enamel. Next, five specimens of each experimental group were subjected to KHN and tristimulus colorimetry tests, and 10 specimens were subjected to surface roughness (SR) tests. The values obtained for the different groups were compared through analysis of variance (ANOVA) followed by a post-hoc Tukey-Kramer test in addition to Student's T-test for paired data. In the intergroup comparison, KHN final differed statistically ( p <0.05). The mean SR final of the experimental groups differed statistically from the GControl group ( p <0.05). In addition, the groups did not differ in color variation ( p >0.05). 10% strontium chloride and 5% potassium nitrate combined with 2% fluoride downplayed morphological changes to the enamel, without interfering with the effectiveness of the bleaching process.
Leasure, J Leigh; Giddabasappa, Anand; Chaney, Shawntay; Johnson, Jerry E; Pothakos, Konstantinos; Lau, Yuen Sum; Fox, Donald A
2008-03-01
Low-level developmental lead exposure is linked to cognitive and neurological disorders in children. However, the long-term effects of gestational lead exposure (GLE) have received little attention. Our goals were to establish a murine model of human equivalent GLE and to determine dose-response effects on body weight, motor functions, and dopamine neurochemistry in year-old offspring. We exposed female C57BL/6 mice to water containing 0, 27 (low), 55 (moderate), or 109 ppm (high) of lead from 2 weeks prior to mating, throughout gestation, and until postnatal day 10 (PN10). Maternal and litter measures, blood lead concentrations ([BPb]), and body weights were obtained throughout the experiment. Locomotor behavior in the absence and presence of amphetamine, running wheel activity, rotarod test, and dopamine utilization were examined in year-old mice. Peak [BPb] were < 1, < or = 10, 24-27, and 33-42 microg/dL in control, low-, moderate- and high-dose GLE groups at PN0-10, respectively. Year-old male but not female GLE mice exhibited late-onset obesity. Similarly, we observed male-specific decreased spontaneous motor activity, increased amphetamine-induced motor activity, and decreased rotarod performance in year-old GLE mice. Levels of dopamine and its major metabolite were altered in year-old male mice, although only forebrain utilization increased. GLE-induced alterations were consistently larger in low-dose GLE mice. Our novel results show that GLE produced permanent male-specific deficits. The nonmonotonic dose-dependent responses showed that low-level GLE produced the most adverse effects. These data reinforce the idea that lifetime measures of dose-response toxicant exposure should be a component of the neurotoxic risk assessment process.
The evaluation of the neutron dose equivalent in the two-bend maze.
Tóth, Á Á; Petrović, B; Jovančević, N; Krmar, M; Rutonjski, L; Čudić, O
2017-04-01
The purpose of this study was to explore the effect of the second bend of the maze, on the neutron dose equivalent, in the 15MV linear accelerator vault, with two bend maze. These two bends of the maze were covered by 32 points where the neutron dose equivalent was measured. There is one available method for estimation of the neutron dose equivalent at the entrance door of the two bend maze which was tested using the results of the measurements. The results of this study show that the neutron equivalent dose at the door of the two bend maze was reduced almost three orders of magnitude. The measured TVD in the first bend (closer to the inner maze entrance) is about 5m. The measured TVD result is close to the TVD values usually used in the proposed models for estimation of neutron dose equivalent at the entrance door of the single bend maze. The results also determined that the TVD in the second bend (next to the maze entrance door) is significantly lower than the TVD values found in the first maze bend. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Radon survey and soil gamma doses in primary schools of Batman, Turkey.
Damla, Nevzat; Aldemir, Kamuran
2014-06-01
A survey was conducted to evaluate levels of indoor radon and gamma doses in 42 primary schools located in Batman, southeastern Anatolia, Turkey. Indoor radon measurements were carried out using CR-39 solid-state nuclear track detector-based radon dosimeters. The overall mean annual (222)Rn activity in the surveyed area was found to be 49 Bq m(-3) (equivalent to an annual effective dose of 0.25 mSv). However, in one of the districts (Besiri) the maximum radon value turned out to be 307 Bq m(-3). The estimated annual effective doses are less than the recommended action level (3-10 mSv). It is found that the radon concentration decreases with increasing floor number. The concentrations of natural and artificial radioisotopes were determined using gamma-ray spectroscopy for soil samples collected in close vicinity of the studied schools. The mean gamma activity concentrations in the soil samples were 31, 25, 329 and 12 Bq kg(-1) for (226)Ra, (232)Th, (40)K and (137)Cs, respectively. The radiological parameters such as the absorbed dose rate in air and the annual effective dose equivalent were calculated. These radiological parameters were evaluated and compared with the internationally recommended values.
Kim, E J; Amezcua, C Martinez; Utterback, P L; Parsons, C M
2008-04-01
There is currently much ongoing research and interest for developing new processing technologies to produce corn distillers dried grains with solubles (DDGS). The current study evaluated a high protein (HP) distillers dried grains (DDG) and a dehydrated corn germ, which are products that can be produced by a modified dry milling process. Two chick experiments were conducted to determine the P bioavailability based on tibia ash. In addition, precision-fed rooster assays were conducted to determine TME(n) and amino acid digestibility. In the first chick assay, a P-deficient cornstarch-dextrose-soybean meal basal diet containing 0.10 to 0.13% nonphytate P was supplemented with 0.0, 0.05, and 0.10% P from KH(2)PO(4) or 7 and 14% conventional DDGS, HP DDG, and corn germ. In the second experiment, the P-deficient basal was supplemented with 7 and 14% conventional DDGS and 12.5 and 25% HP DDG. New Hampshire x Columbian female chicks were fed the experimental diets from 9 to 22 d posthatch, and bioavailability of P was estimated using the slope-ratio method where tibia ash was regressed on P intake. The total P content (90% DM basis) of the conventional DDGS, HP DDG, and corn germ were 0.76, 0.33, and 1.29%, respectively. Bioavailabilities of the P in conventional DDGS, HP DDG, and corn germ relative to KH(2)PO(4) were found to be 60, 56, and 25%, respectively. The TME(n) in conventional roosters was found to be significantly reduced for HP DDG and increased for the corn germ when compared with the conventional DDGS. The protein content (90% DM basis) of the HP DDG and corn germ was 33 and 14%, respectively, and the total lysine as a % of CP was approximately 2 times greater for the corn germ than for the HP DDG. Amino acid digestibilities in cecectomized roosters were consistently higher for the corn germ than for the HP DDG, which was similar to conventional DDGS.
Brawley, V; Bhatia, J; Karp, W B
1998-06-15
The effect of sodium metabisulfite (MBS) on hydrogen peroxide (HP) production in model and commercial amino acid solutions exposed to phototherapy light was studied. Model and commercial pediatric amino acid solutions were prepared such that the amino acid concentration was 1%. MBS concentration, riboflavin concentration, and duration of exposure to phototherapy light were varied to determine the effect on HP production. Control solutions were kept in the dark. HP production was assayed in the model amino acid solutions by using potassium iodide in the presence of ammonium molybdate. In all experiments, HP production was measured at 360 nm in the presence and absence of catalase. In light-exposed solutions, HP production increased linearly for several hours and reached a plateau by eight hours. A mean maximum of 940 microM was produced (data pooled for all solutions). No detectable HP was generated in the solutions kept in the dark. After two hours of light exposure, it was necessary to add at least 10 times more MBS than is typically found in commercial total parenteral nutrient solutions to scavenge all the HP produced. An average of up to 940 microM of HP was produced in model and commercial pediatric parenteral 1% amino acid solutions in the presence of phototherapy light and clinically relevant concentrations of riboflavin and MBS. Light exposure decreased the antioxidant effect of MBS.
"Cthulhuic Literacy": Teaching Secondary English with a Dose of Lovecraft
ERIC Educational Resources Information Center
Cole, David R.
2014-01-01
This paper suggests how the "weird fiction" of H.P. Lovecraft might be mobilised within secondary English classrooms to examine aspects of visual literacy, literary style, narrative form and intertextuality. The approach that is outlined is characterised, after Lovecraft's famous monster, as a "Cthulhuic literacy" and is…
de Campos, Tarcisio Passos Ribeiro; Nogueira, Luciana Batista; Trindade, Bruno; Cuperschmid, Ethel Mizrahy
2016-01-01
To provide a comparative dosimetric analysis of permanent implants of Ho(166)-seeds and temporary HDR Ir(192)-brachytherapy through computational simulation. Brachytherapy with Ir(192)-HDR or LDR based on temporary wires or permanent radioactive seed implants can be used as dose reinforcement for breast radiation therapy. Permanent breast implants have not been a practical clinical routine; although, I(125) and Pd(103)-seeds have already been reported. Biodegradable Ho(166)-ceramic-seeds have been addressed recently. Simulations of implants of nine Ho(166)-seeds and equivalent with HDR Ir(192)-brachytherapy were elaborated in MCNP5, shaped in a computational multivoxel simulator which reproduced a female thorax phantom. Spatial dose rate distributions and dose-volume histograms were generated. Protocol's analysis involving exposure time, seed's activities and dose were performed. Permanent Ho(166)-seed implants presented a maximum dose rate per unit of contained activity (MDR) of 1.1601 μGy h(-1) Bq(-1); and, a normalized MDR in standard points (8 mm, equidistant to 03-seeds - SP1, 10 mm - SP2) of 1.0% (SP1) and 0.5% (SP2), respectively. Ir(192)-brachytherapy presented MDR of 4.3945 × 10(-3) μGy h(-1) Bq(-1); and, 30% (SP1), and 20% (SP2). Therefore, seed's implant activities of 333 MBq (Ho(166)) and 259 GBq (Ir(192)) produced prescribed doses of 58 Gy (SP1; 5d) and 56 Gy (SP1, 5 fractions, 6 min), respectively. Breast Ho(166)-implants of 37-111 MBq are attractive due to the high dose rate near 6-10 mm from seeds, equivalent to Ir(192)-brachytherapy of 259 GBq (3 fractions, 6 min) providing similar dose in standard points at a week; however, with spatial dose distribution better confined. The seed positioning can be adjusted for controlling the breast tumor, in stages I and II, in flat and deep tumors, without any breast volumetric limitation.
Writing time estimation of EB mask writer EBM-9000 for hp16nm/logic11nm node generation
NASA Astrophysics Data System (ADS)
Kamikubo, Takashi; Takekoshi, Hidekazu; Ogasawara, Munehiro; Yamada, Hirokazu; Hattori, Kiyoshi
2014-10-01
The scaling of semiconductor devices is slowing down because of the difficulty in establishing their functionality at the nano-size level and also because of the limitations in fabrications, mainly the delay of EUV lithography. While multigate devices (FinFET) are currently the main driver for scalability, other types of devices, such as 3D devices, are being realized to relax the scaling of the node. In lithography, double or multiple patterning using ArF immersion scanners is still a realistic solution offered for the hp16nm node fabrication. Other lithography candidates are those called NGL (Next Generation Lithography), such as DSA (Directed-Self-Assembling) or nanoimprint. In such situations, shot count for mask making by electron beam writers will not increase. Except for some layers, it is not increasing as previously predicted. On the other hand, there is another aspect that increases writing time. The exposure dose for mask writing is getting higher to meet tighter specifications of CD uniformity, in other words, reduce LER. To satisfy these requirements, a new electron beam mask writer, EBM-9000, has been developed for hp16nm/logic11nm generation. Electron optical system, which has the immersion lens system, was evolved from EBM-8000 to achieve higher current density of 800A/cm2. In this paper, recent shot count and dose trend are discussed. Also, writing time is estimated for the requirements in EBM-9000.
Hashimoto, Hideki; Ishijima, Toshimichi; Suzuki, Katsuhiko; Higuchi, Mitsuru
2016-09-01
Reproductive hormones are likely to be involved in thermoregulation through body fluid dynamics. In the present study, we aimed to investigate the effect of the menstrual cycle and water consumption on physiological responses to prolonged exercise at moderate intensity in hot conditions. Eight healthy young women with regular menstrual cycles performed cycling exercise for 90 minutes at 50% V̇O2peak intensity during the low progesterone (LP) level phase and high progesterone (HP) level phase, with or without water consumption, under hot conditions (30°C, 50% relative humidity). For the water consumption trials, subjects ingested water equivalent to the loss in body weight that occurred in the earlier non-consumption trial. For all four trials, rectal temperature, cardiorespiratory responses, and ratings of perceived exertion (RPE) were measured. Throughout the 90-minute exercise period, rectal temperatures during HP were higher than during LP by an average of 0.4 °C in the non-consumption trial (P<0.01) and 0.2 °C in the water consumption trial (P<0.05). During exercise, water consumption affected the changes in rectal temperature and heat rate (HR) during HP, but it did not exert these effects during LP. Furthermore, we found a negative correlation between estradiol levels and rectal temperature during LP. During prolonged exercise at moderate intensity under hot conditions, water consumption is likely to be useful for suppressing the associated increase in body temperature and HR, particularly during HP, whereas estradiol appears to be useful for suppressing the increase in rectal temperature during LP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soref, Cheryl M.; Hacker, Timothy A.; Fahl, William E., E-mail: fahl@oncology.wisc.edu
Purpose: A new aminothiol, PrC-210, was tested for orally conferred radioprotection (rats, mice; 9.0 Gy whole-body, which was otherwise lethal to 100% of the animals) and presence of the debilitating side effects (nausea/vomiting, hypotension/fainting) that restrict use of the current aminothiol, amifostine (Ethyol, WR-2721). Methods and Materials: PrC-210 in water was administered to rats and mice at times before irradiation, and percent-survival was recorded for 60 days. Subcutaneous (SC) amifostine (positive control) or SC PrC-210 was administered to ferrets (Mustela putorius furo) and retching/emesis responses were recorded. Intraperitoneal amifostine (positive control) or PrC-210 was administered to arterial cannulated rats tomore » score drug-induced hypotension. Results: Oral PrC-210 conferred 100% survival in rat and mouse models against an otherwise 100% lethal whole-body radiation dose (9.0 Gy). Oral PrC-210, administered by gavage 30-90 min before irradiation, conferred a broad window of radioprotection. The comparison of PrC-210 and amifostine side effects was striking because there was no retching or emesis in 10 ferrets treated with PrC-210 and no induced hypotension in arterial cannulated rats treated with PrC-210. The tested PrC-210 doses were the ferret and rat equivalent doses of the 0.5 maximum tolerated dose (MTD) PrC-210 dose in mice. The human equivalent of this mouse 0.5 MTD PrC-210 dose would likely be the highest PrC-210 dose used in humans. By comparison, the mouse 0.5 MTD amifostine dose, 400 {mu}g/g body weight (equivalent to the human amifostine dose of 910 mg/m{sup 2}), when tested at equivalent ferret and rat doses in the above models produced 100% retching/vomiting in ferrets and 100% incidence of significant, progressive hypotension in rats. Conclusions: The PrC-210 aminothiol, with no detectable nausea/vomiting or hypotension side effects in these preclinical models, is a logical candidate for human drug development to use in healthy humans in a wide variety of radioprotection settings, including medical radiation, space travel, and nuclear accidents.« less
High level gamma radiation effects on Cernox™ cryogenic temperature sensors
NASA Astrophysics Data System (ADS)
Courts, S. S.
2017-12-01
Cryogenic temperature sensors are used in high energy particle colliders to monitor the temperatures of superconducting magnets, superconducting RF cavities, and cryogen infrastructure. While not intentional, these components are irradiated by leakage radiation during operation of the collider. A common type of cryogenic thermometer used in these applications is the Cernox™ resistance thermometer (CxRT) manufactured by Lake Shore Cryotronics, Inc. This work examines the radiation-induced calibration offsets on CxRT models CX-1050-SD-HT and CX-1080-SD-HT resulting from exposure to very high levels of gamma radiation. Samples from two different wafers of each of the two models tested were subjected to a gamma radiation dose ranging from 10 kGy to 5 MGy. Data were analysed in terms of the temperature-equivalent resistance change between pre- and post-irradiation calibrations. The data show that the resistance of these devices decreased following irradiation resulting in positive temperature offsets across the 1.4 K to 330 K temperature range. Variations in response were observed between wafers of the same CxRT model. Overall, the offsets increased with increasing temperature and increasing gamma radiation dose. At 1.8 K, the average offset increased from 0 mK to +13 mK as total dose increased from 10 kGy to 5 MGy. At 4.2 K, the average offset increased from +4 mK to +33 mK as total dose increased from 10 kGy to 5 MGy. Equivalent temperature offset data are presented over the 1.4 K to 330 K temperature range by CxRT model, wafer, and total gamma dose.
Wu, Panpan; Li, Fajie; Zhang, Jianyong; Yang, Bin; Ji, Zhaojie; Chen, Weidong
2017-03-11
Hawthorn fruit (HF) is a well-known traditional medicine in China with the effects of improving digestion and regulating qi-flowing for removing blood stasis. Modern pharmacological experiments showed that HF extract has various pharmaceutical properties and flavonoids are considered as the main bioactive compounds. In this paper, Diaion HP-20 adsorption chromatography was used to enrich flavonoids in PHF, and the phytochemical composition of EPHF was analyzed by high performance liquid chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LC-MS). In addition, EPHF's antioxidant capacity, acetylcholinesterase (AChE) inhibitory activity and cytotoxic activity were evaluated. EPHF was obtained by Diaion HP-20 adsorption chromatography. Phytochemical composition of EPHF was analyzed qualitatively and quantitatively using HPLC and LC-MS. Radical scavenging capacity of EPHF was estimated using 2,2-diphenyl-1-picryhydrazyl (DPPH) assay and oxygen radical absorbance capacity (ORAC) assay. The AChE inhibitory activity of EPHF was evaluated by Ellman method. Cytotoxic activity of EPHF was assessed by means of MTT assay. Eight kinds of components were identified, in which ideain with the value of 179.4 mg/g was identified to be present in the highest level in EPHF, followed by (-)-epicatechin, chlorogenic acid, cyanidin 3-arabinoside, hyperoside and isoquercitrin at the concentrations of 40.9, 10.0, 1.4, 0.4 and 0.2 mg/g, respectively. The contents of these compounds in EPHF were much higher than those in PHF and HF. In addition, EPHF exhibited strong antioxidant and AChE inhibitory activity (ORAC value: 11.65 ± 2.37 μM Trolox equivalents (TE)/mg, DPPH IC 50 value: 6.72 μg/mL, anti-AChE activity IC 50 value: 11.72 μg/mL) compared with PHF and HF. Moreover, EPHF exhibited high levels of cytotoxicity on MCF-7 and SKOV-3 human tumour cell lines in a dose-dependent manner with the IC 50 of 2.76 and 80.11 μg/mL, respectively. Macroporous resin is useful for the extraction and separation of the total flavonoids from PHF. The contents of flavonoids especially anthocyanin in EPHF were increased significantly compared with the PHF, and EPHF exhibited strong antioxidant, AChE inhibitory activity and cytotoxicity on human tumour cells.
Monte Carlo calculation of the neutron dose to a fetus at commercial flight altitudes
NASA Astrophysics Data System (ADS)
Alves, M. C.; Galeano, D. C.; Santos, W. S.; Hunt, John G.; d'Errico, Francesco; Souza, S. O.; de Carvalho Júnior, A. B.
2017-11-01
Aircrew members are exposed to primary cosmic rays as well as to secondary radiations from the interaction of cosmic rays with the atmosphere and with the aircraft. The radiation field at flight altitudes comprises neutrons, protons, electrons, positrons, photons, muons and pions. Generally, 50% of the effective dose to airplane passengers is due to neutrons. Care must be taken especially with pregnant aircrew members and frequent fliers so that the equivalent dose to the fetus will not exceed prescribed limits during pregnancy (1 mSv according to ICRP, and 5 mSv according to NCRP). Therefore, it is necessary to evaluate the equivalent dose to a fetus in the maternal womb. Up to now, the equivalent dose rate to a fetus at commercial flight altitudes was obtained using stylized pregnant-female phantom models. The aim of this study was calculating neutron fluence to dose conversion coefficients for a fetus of six months of gestation age using a new, realistic pregnant-female mesh-phantom. The equivalent dose rate to a fetus during an intercontinental flight was also calculated by folding our conversion coefficients with published spectral neutron flux data. The calculated equivalent dose rate to the fetus was 2.35 μSv.h-1, that is 1.5 times higher than equivalent dose rates reported in the literature. The neutron fluence to dose conversion coefficients for the fetus calculated in this study were 2.7, 3.1 and 3.9 times higher than those from previous studies using fetus models of 3, 6 and 9 months of gestation age, respectively. The differences between our study and data from the literature highlight the importance of using more realistic anthropomorphic phantoms to estimate doses to a fetus in pregnant aircrew members.
Stähler, Frank Nils; Odenbreit, Stefan; Haas, Rainer; Wilrich, Julia; Vliet, Arnoud H. M. Van; Kusters, Johannes G.; Kist, Manfred; Bereswill, Stefan
2006-01-01
Maintaining metal homeostasis is crucial for the adaptation of Helicobacter pylori to the gastric environment. Iron, copper, and nickel homeostasis has recently been demonstrated to be required for the establishment of H. pylori infection in animal models. Here we demonstrate that the HP0969-0971 gene cluster encoding the Czc-type metal export pump homologs HP0969, HP0970, and the H. pylori-specific protein HP0971 forms part of a novel H. pylori metal resistance determinant, which is required for gastric colonization and for the modulation of urease activity. Insertional mutagenesis of the HP0971, HP0970, or HP0969 genes in H. pylori reference strain 26695 resulted in increased sensitivity to cadmium, zinc, and nickel (czn), suggesting that the encoded proteins constitute a metal-specific export pump. Accordingly, the genes were designated cznC (HP0971), cznB (HP0970), and cznA (HP0969). The CznC and CznA proteins play a predominant role in nickel homeostasis, since only the cznC and cznA mutants but not the cznB mutant displayed an 8- to 10-fold increase in urease activity. Nickel-specific affinity chromatography demonstrated that recombinant versions of CznC and CznB can bind to nickel and that the purified CznB protein interacted with cadmium and zinc, since both metals competitively inhibited nickel binding. Finally, single cznA, cznB, and cznC mutants did not colonize the stomach in a Mongolian gerbil-based animal model. This demonstrates that the metal export functions of H. pylori cznABC are essential for gastric colonization and underlines the extraordinary importance of metal ion homeostasis for the survival of H. pylori in the gastric environment. PMID:16790756
Diffenderfer, Eric S; Ainsley, Christopher G; Kirk, Maura L; McDonough, James E; Maughan, Richard L
2011-11-01
To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. Hydrogenous and nonhydrogenous ionization chambers were constructed with large volumes to enable measurements of absorbed doses below 10(-4) Gy in mixed radiation fields using the dual ionization chamber method for mixed-field dosimetry. Neutron dose measurements were made with a nominal 230 MeV proton beam incident on a closed tungsten alloy MLC and a solid brass block. The chambers were cross-calibrated against a (60)Co-calibrated Farmer chamber in water using a 6 MV x-ray beam and Monte Carlo simulations were performed to account for variations in ionization chamber response due to differences in secondary neutron energy spectra. The neutron and combined proton plus γ-ray absorbed doses are shown to be nearly equivalent downstream from either a closed tungsten alloy MLC or a solid brass block. At 10 cm downstream from the distal edge of the collimating material the neutron dose from the closed MLC was (5.3 ± 0.4) × 10(- 5) Gy/Gy. The neutron dose with brass was (6.4 ± 0.7) × 10(- 5) Gy/Gy. Further from the secondary neutron source, at 50 cm, the neutron doses remain close for both the MLC and brass block at (6.9 ± 0.6) × 10(- 6) Gy/Gy and (6.3 ± 0.7) × 10(- 6) Gy/Gy, respectively. The dual ionization chamber method is suitable for measuring secondary neutron doses resulting from proton irradiation. The results of measurements downstream from a closed tungsten alloy MLC and a brass block indicate that, even in an overly pessimistic worst-case scenario, secondary neutron production in a tungsten alloy MLC leads to absorbed doses that are nearly equivalent to those seen from brass collimators. Therefore, the choice of tungsten alloy in constructing the leaves of a proton MLC is appropriate, and does not lead to a substantial increase in the secondary neutron dose to the patient compared to that generated in a brass collimator.
Testing Moderating Detection Systems with {sup 252}Cf-Based Reference Neutron Fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hertel, Nolan E.; Sweezy, Jeremy; Sauber, Jeremiah S.
Calibration measurements were carried out on a probe designed to measure ambient dose equivalent in accordance with ICRP Pub 60 recommendations. It consists of a cylindrical {sup 3}He proportional counter surrounded by a 25-cm-diameter spherical polyethylene moderator. Its neutron response is optimized for dose rate measurements of neutrons between thermal energies and 20 MeV. The instrument was used to measure the dose rate in four separate neutron fields: unmoderated {sup 252}Cf, D{sub 2}O-moderated {sup 252}Cf, polyethylene-moderated {sup 252}Cf, and WEP neutron howitzer with {sup 252}Cf at its center. Dose equivalent measurements were performed at source-detector centerline distances from 50 tomore » 200 cm. The ratio of air-scatter- and room-return-corrected ambient dose equivalent rates to ambient dose equivalent rates calculated with the code MCNP are tabulated.« less
Induced radioactivity in the forward shielding and semiconductor tracker of the ATLAS detector.
Bĕdajánek, I; Linhart, V; Stekl, I; Pospísil, S; Kolros, A; Kovalenko, V
2005-01-01
The radioactivity induced in the forward shielding, copper collimator and semiconductor tracker modules of the ATLAS detector has been studied. The ATLAS detector is a long-term experiment which, during operation, will require to have service and access to all of its parts and components. The radioactivity induced in the forward shielding was calculated by Monte Carlo methods based on GEANT3 software tool. The results show that the equivalent dose rates on the outer surface of the forward shielding are very low (at most 0.038 microSv h(-1)). On the other hand, the equivalent dose rates are significantly higher on the inner surface of the forward shielding (up to 661 microSv h(-1)) and, especially, at the copper collimator close to the beampipe (up to 60 mSv h(-1)). The radioactivity induced in the semiconductor tracker modules was studied experimentally. The module was activated by neutrons in a training nuclear reactor and the delayed gamma ray spectra were measured. From these measurements, the equivalent dose rate on the surface of the semiconductor tracker module was estimated to be < 100 microSv h(-1) after 100 d of Large Hadron Collider (LHC) operation and 10 d of cooling.