Sample records for dosimetry program manual

  1. Internal dosimetry technical basis manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-12-20

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophicalmore » discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.« less

  2. Hanford Internal Dosimetry Program Manual, PNL-MA-552

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2009-09-24

    This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

  3. Hanford Internal Dosimetry Program Manual, PNL-MA-552

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2003-10-10

    This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP). It describes the roles of and relationships between the IDP and site contractors, and provides recommendations and guidance for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs. Guidance includes identifying conditions under which workers should be placed on bioassay programs, types, descritptions, and capabilities of measurements, suggested routine bioassay programs, limitations on services, and practices for recording and reporting results.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goke, Sarah Hayes; Elliott, Nathan Ryan

    The Sandia National Laboratories’ Internal Dosimetry Technical Basis Manual is intended to provide extended technical discussion and justification of the internal dosimetry program at SNL. It serves to record the approach to evaluating internal doses from radiobioassay data, and where appropriate, from workplace monitoring data per the Department of Energy Internal Dosimetry Program Guide DOE G 441.1C. The discussion contained herein is directed primarily to current and future SNL internal dosimetrists. In an effort to conserve space in the TBM and avoid duplication, it contains numerous references providing an entry point into the internal dosimetry literature relevant to this program.more » The TBM is not intended to act as a policy or procedure statement, but will supplement the information normally found in procedures or policy documents. The internal dosimetry program outlined in this manual is intended to meet the requirements of Federal Rule 10CFR835 for monitoring the workplace and for assessing internal radiation doses to workers.« less

  5. Hanford internal dosimetry program manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, E.H.; Sula, M.J.; Bihl, D.E.

    1989-10-01

    This document describes the Hanford Internal Dosimetry program. Program Services include administrating the bioassay monitoring program, evaluating and documenting assessments of internal exposure and dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating internal radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. 13 refs., 16 figs., 42 tabs.

  6. Methods and Models of the Hanford Internal Dosimetry Program, PNNL-MA-860

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2003-01-03

    This manual describes the technical basis for the design of the routine radiobioassay monitoring program and assessments of internal dose. Its purpose is to provide a historical record of the methods, models, and assumptions used for internal dosimetry at Hanford, and serve as a technical reference for radiation protection and dosimetry staff.

  7. Methods and Models of the Hanford Internal Dosimetry Program, PNNL-MA-860

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2009-09-30

    The Hanford Internal Dosimetry Program (HIDP) provides internal dosimetry support services for operations at the Hanford Site. The HIDP is staffed and managed by the Radiation and Health Technology group, within the Pacific Northwest National Laboratory (PNNL). Operations supported by the HIDP include research and development, the decontamination and decommissioning of facilities formerly used to produce and purify plutonium, and waste management activities. Radioelements of particular interest are plutonium, uranium, americium, tritium, and the fission and activation product radionuclides 137Cs, 90Sr, and 60Co. This manual describes the technical basis for the design of the routine bioassay monitoring program and formore » assessment of internal dose. The purposes of the manual are as follows: • Provide assurance that the HIDP derives from a sound technical base. • Promote the consistency and continuity of routine program activities. • Provide a historical record. • Serve as a technical reference for radiation protection personnel. • Aid in identifying and planning for future needs.« less

  8. Nuclear Weapon Accident Response Procedures (NARP) Manual

    DTIC Science & Technology

    1990-09-01

    5-E-13 5-E-5 Field M onitoring Data Log ................................................ 5-E-15 5-E-6 TLD Measurement Collection... Dosimetry Program and the USAF Master Radiation Exposure Registery, Oct 73. (u) OPNAVINST 3440.15, Minimum Criteria and Standards for Navy and Marine...ordnance to prevent an unacceptable detonation. Dosimetry . The measurement of radiation doses as it applies to both the devices used idosimeters) and to the

  9. [Automatic Extraction and Analysis of Dosimetry Data in Radiotherapy Plans].

    PubMed

    Song, Wei; Zhao, Di; Lu, Hong; Zhang, Biyun; Ma, Jun; Yu, Dahai

    To improve the efficiency and accuracy of extraction and analysis of dosimetry data in radiotherapy plans for a batch of patients. With the interface function provided in Matlab platform, a program was written to extract the dosimetry data exported from treatment planning system in DICOM RT format and exported the dose-volume data to an Excel file with the SPSS compatible format. This method was compared with manual operation for 14 gastric carcinoma patients to validate the efficiency and accuracy. The output Excel data were compatible with SPSS in format, the dosimetry data error for PTV dose interval of 90%-98%, PTV dose interval of 99%-106% and all OARs were -3.48E-5 ± 3.01E-5, -1.11E-3 ± 7.68E-4, -7.85E-5 ± 9.91E-5 respectively. Compared with manual operation, the time required was reduced from 5.3 h to 0.19 h and input error was reduced from 0.002 to 0. The automatic extraction of dosimetry data in DICOM RT format for batch patients, the SPSS compatible data exportation, quick analysis were achieved in this paper. The efficiency of clinical researches based on dosimetry data analysis of large number of patients will be improved with this methods.

  10. Hanford Internal Dosimetry Project manual. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, E.H.; Bihl, D.E.; MacLellan, J.A.

    1994-07-01

    This document describes the Hanford Internal Dosimetry Project, as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy and its Hanford contractors. Project services include administrating the bioassay monitoring program, evaluating and documenting assessment of potential intakes and internal dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. Specific chapters deal with the following subjects: practices of the project, including interpretation of applicable DOE Orders, regulations, andmore » guidance into criteria for assessment, documentation, and reporting of doses; assessment of internal dose, including summary explanations of when and how assessments are performed; recording and reporting practices for internal dose; selection of workers for bioassay monitoring and establishment of type and frequency of bioassay measurements; capability and scheduling of bioassay monitoring services; recommended dosimetry response to potential internal exposure incidents; quality control and quality assurance provisions of the program.« less

  11. Safety: Radiation Protection Manual

    DTIC Science & Technology

    1997-05-30

    t e c h n i c a l publication requires it, (2) personnel are required to wear dosimetry , EM 385-1-80 30 May 97 2-4 (3) personnel are required to...of SOPs, review of dosimetry results, changes in standards or guidance, equipment changes, and any other pertinent radiation safety information that...Table 3-4. The EDE is used in dosimetry to account for different organs having different sensitivities to radiation. Table 3-4 Weighting Factors

  12. Reference dosimeter system of the iaea

    NASA Astrophysics Data System (ADS)

    Mehta, Kishor; Girzikowsky, Reinhard

    1995-09-01

    Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit.

  13. A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance

    NASA Astrophysics Data System (ADS)

    Wang, Jiazhou; Chen, Wenzhou; Studenski, Matthew; Cui, Yunfeng; Lee, Andrew J.; Xiao, Ying

    2013-07-01

    The goal of this work is to develop a plan-quality evaluation program for clinical routine and multi-institutional clinical trials so that the overall evaluation efficiency is improved. In multi-institutional clinical trials evaluating the plan quality is a time-consuming and labor-intensive process. In this note, we present a semi-automated plan-quality evaluation program which combines MIMVista, Java/MATLAB, and extensible markup language (XML). More specifically, MIMVista is used for data visualization; Java and its powerful function library are implemented for calculating dosimetry parameters; and to improve the clarity of the index definitions, XML is applied. The accuracy and the efficiency of the program were evaluated by comparing the results of the program with the manually recorded results in two RTOG trials. A slight difference of about 0.2% in volume or 0.6 Gy in dose between the semi-automated program and manual recording was observed. According to the criteria of indices, there are minimal differences between the two methods. The evaluation time is reduced from 10-20 min to 2 min by applying the semi-automated plan-quality evaluation program.

  14. Nondestructive Inspection (NDI) Facility Radiation Protection Survey for Homestead AFB, FL

    DTIC Science & Technology

    2012-10-31

    worker radiation dosimetry records, Bioenvironmental Engineering’s occupational safety records, NDI’s operating procedures/instructions, radiation...Nondestructive Inspection Methods (2) Air Force Manual 48-125, Personnel Ionizing Radiation Dosimetry (3) Air Force Occupational Safety and Health Standard...radiography 3. TLDs properly stored (AFMAN 48-125; T.O. 33B-1-1, 6.8.5.4.4) 4. TLDs returned to storage rack at the end

  15. Technical basis for external dosimetry at the Waste Isolation Pilot Plant (WIPP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bradley, E.W.; Wu, C.F.; Goff, T.E.

    1993-12-31

    The WIPP External Dosimetry Program, administered by Westinghouse Electric Corporation, Waste Isolation Division, for the US Department of Energy (DOE), provides external dosimetry support services for operations at the Waste Isolation Pilot Plant (WIPP) Site. These operations include the receipt, experimentation with, storage, and disposal of transuranic (TRU) wastes. This document describes the technical basis for the WIPP External Radiation Dosimetry Program. The purposes of this document are to: (1) provide assurance that the WIPP External Radiation Dosimetry Program is in compliance with all regulatory requirements, (2) provide assurance that the WIPP External Radiation Dosimetry Program is derived from amore » sound technical base, (3) serve as a technical reference for radiation protection personnel, and (4) aid in identifying and planning for future needs. The external radiation exposure fields are those that are documented in the WIPP Final Safety Analysis Report.« less

  16. Student Perceptions of an Online Medical Dosimetry Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenards, Nishele, E-mail: lenards.nish@uwlax.ed

    2011-07-01

    The University of Wisconsin-La Crosse offers the first online medical dosimetry program in the nation. There is no data to research a program of this type. This research consisted of the evaluation of other distance education programs including health profession programs in addition to face-to-face medical dosimetry programs. There was a need to collect and analyze student perceptions of online learning in medical dosimetry. This research provided a guide for future implementation by other programs as well as validated the University of Wisconsin-La Crosse program. Methodology used consisted of an electronic survey sent to all previous and currently enrolled studentsmore » in the University of Wisconsin-La Crosse medical dosimetry program. The survey was both quantitative and qualitative in demonstrating attitudinal perceptions of students in the program. Quantitative data was collected and analyzed using a 5-point Likert scale. Qualitative data was gathered based on the open-ended responses and the identifying themes from the responses. The results demonstrated an overall satisfaction with this program, the instructor, and the online courses. Students felt a sense of belonging to the courses and the program. Considering that a majority of the students had never taken an online course previously, the students felt there were no technology issues. Future research should include an evaluation of board exam statistics for students enrolled in the online and face-to-face medical dosimetry programs.« less

  17. NV/YMP radiological control manual, Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gile, A.L.

    The Nevada Test Site (NTS) and the adjacent Yucca Mountain Project (YMP) are located in Nye County, Nevada. The NTS has been the primary location for testing nuclear explosives in the continental US since 1951. Current activities include operating low-level radioactive and mixed waste disposal facilities for US defense-generated waste, assembly/disassembly of special experiments, surface cleanup and site characterization of contaminated land areas, and non-nuclear test operations such as controlled spills of hazardous materials at the hazardous Materials (HAZMAT) Spill Center (HSC). Currently, the major potential for occupational radiation exposure is associated with the burial of low-level nuclear waste andmore » the handling of radioactive sources. Planned future remediation of contaminated land areas may also result in radiological exposures. The NV/YMP Radiological Control Manual, Revision 2, represents DOE-accepted guidelines and best practices for implementing Nevada Test Site and Yucca Mountain Project Radiation Protection Programs in accordance with the requirements of Title 10 Code of Federal Regulations Part 835, Occupational Radiation Protection. These programs provide protection for approximately 3,000 employees and visitors annually and include coverage for the on-site activities for both personnel and the environment. The personnel protection effort includes a DOE Laboratory Accreditation Program accredited dosimetry and personnel bioassay programs including in-vivo counting, routine workplace air sampling, personnel monitoring, and programmatic and job-specific As Low as Reasonably Achievable considerations.« less

  18. USAF Summer Research Program - 1993 High School Apprenticeship Program Final Reports, Volume 12, Armstrong Laboratory

    DTIC Science & Technology

    1993-12-01

    on Panasonic TLD . Panasonic Industrial Company; Secaucus, New Jersey. 5. Thurlow, Ronald M. "Neutron Dosimetry Using a Panasonic Thermoluminescent...Radiation Dosimetry Branch Brooks Air Force Base San Antonio, Texas 78235 Final Report for: AFOSR Summer Research Program Armstrong Laboratory Sponsored...Associate Radiation Dosimetry Branch Armstrong Laboratory Abstract In an attempt to improve personnel monitoring for neutron emissions, Panasonic has

  19. Relationship between student selection criteria and learner success for medical dosimetry students

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, Jamie, E-mail: jabaker@mdanderson.org; Tucker, Debra; Raynes, Edilberto

    Medical dosimetry education occupies a specialized branch of allied health higher education. Noted international shortages of health care workers, reduced university funding, limitations on faculty staffing, trends in learner attrition, and increased enrollment of nontraditional students force medical dosimetry educational leadership to reevaluate current admission practices. Program officials wish to select medical dosimetry students with the best chances of successful graduation. The purpose of the quantitative ex post facto correlation study was to investigate the relationship between applicant characteristics (cumulative undergraduate grade point average (GPA), science grade point average (SGPA), prior experience as a radiation therapist, and previous academic degrees)more » and the successful completion of a medical dosimetry program, as measured by graduation. A key finding from the quantitative study was the statistically significant positive correlation between a student's previous degree and his or her successful graduation from the medical dosimetry program. Future research investigations could include a larger research sample, representative of more medical dosimetry student populations, and additional studies concerning the relationship of previous work as a radiation therapist and the effect on success as a medical dosimetry student. Based on the quantitative correlation analysis, medical dosimetry leadership on admissions committees could revise student selection rubrics to place less emphasis on an applicant's undergraduate cumulative GPA and increase the weight assigned to previous degrees.« less

  20. Relationship between student selection criteria and learner success for medical dosimetry students.

    PubMed

    Baker, Jamie; Tucker, Debra; Raynes, Edilberto; Aitken, Florence; Allen, Pamela

    2016-01-01

    Medical dosimetry education occupies a specialized branch of allied health higher education. Noted international shortages of health care workers, reduced university funding, limitations on faculty staffing, trends in learner attrition, and increased enrollment of nontraditional students force medical dosimetry educational leadership to reevaluate current admission practices. Program officials wish to select medical dosimetry students with the best chances of successful graduation. The purpose of the quantitative ex post facto correlation study was to investigate the relationship between applicant characteristics (cumulative undergraduate grade point average (GPA), science grade point average (SGPA), prior experience as a radiation therapist, and previous academic degrees) and the successful completion of a medical dosimetry program, as measured by graduation. A key finding from the quantitative study was the statistically significant positive correlation between a student׳s previous degree and his or her successful graduation from the medical dosimetry program. Future research investigations could include a larger research sample, representative of more medical dosimetry student populations, and additional studies concerning the relationship of previous work as a radiation therapist and the effect on success as a medical dosimetry student. Based on the quantitative correlation analysis, medical dosimetry leadership on admissions committees could revise student selection rubrics to place less emphasis on an applicant׳s undergraduate cumulative GPA and increase the weight assigned to previous degrees. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  1. Evaluation of an automated karyotyping system for chromosome aberration analysis

    NASA Technical Reports Server (NTRS)

    Prichard, Howard M.

    1987-01-01

    Chromosome aberration analysis is a promising complement to conventional radiation dosimetry, particularly in the complex radiation fields encountered in the space environment. The capabilities of a recently developed automated karyotyping system were evaluated both to determine current capabilities and limitations and to suggest areas where future development should be emphasized. Cells exposed to radiometric chemicals and to photon and particulate radiation were evaluated by manual inspection and by automated karyotyping. It was demonstrated that the evaluated programs were appropriate for image digitization, storage, and transmission. However, automated and semi-automated scoring techniques must be advanced significantly if in-flight chromosome aberration analysis is to be practical. A degree of artificial intelligence may be necessary to realize this goal.

  2. Fourth conference on radiation protection and dosimetry: Proceedings, program, and abstracts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casson, W.H.; Thein, C.M.; Bogard, J.S.

    This Conference is the fourth in a series of conferences organized by staff members of Oak Ridge National Laboratory in an effort to improve communication in the field of radiation protection and dosimetry. Scientists, regulators, managers, professionals, technologists, and vendors from the United States and countries around the world have taken advantage of this opportunity to meet with their contemporaries and peers in order to exchange information and ideas. The program includes over 100 papers in 9 sessions, plus an additional session for works in progress. Papers are presented in external dosimetry, internal dosimetry, radiation protection programs and assessments, developmentsmore » in instrumentation and materials, environmental and medical applications, and on topics related to standards, accreditation, and calibration. Individual papers are indexed separately on EDB.« less

  3. SU-E-T-497: Semi-Automated in Vivo Radiochromic Film Dosimetry Using a Novel Image Processing Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reyhan, M; Yue, N

    Purpose: To validate an automated image processing algorithm designed to detect the center of radiochromic film used for in vivo film dosimetry against the current gold standard of manual selection. Methods: An image processing algorithm was developed to automatically select the region of interest (ROI) in *.tiff images that contain multiple pieces of radiochromic film (0.5x1.3cm{sup 2}). After a user has linked a calibration file to the processing algorithm and selected a *.tiff file for processing, an ROI is automatically detected for all films by a combination of thresholding and erosion, which removes edges and any additional markings for orientation.more » Calibration is applied to the mean pixel values from the ROIs and a *.tiff image is output displaying the original image with an overlay of the ROIs and the measured doses. Validation of the algorithm was determined by comparing in vivo dose determined using the current gold standard (manually drawn ROIs) versus automated ROIs for n=420 scanned films. Bland-Altman analysis, paired t-test, and linear regression were performed to demonstrate agreement between the processes. Results: The measured doses ranged from 0.2-886.6cGy. Bland-Altman analysis of the two techniques (automatic minus manual) revealed a bias of -0.28cGy and a 95% confidence interval of (5.5cGy,-6.1cGy). These values demonstrate excellent agreement between the two techniques. Paired t-test results showed no statistical differences between the two techniques, p=0.98. Linear regression with a forced zero intercept demonstrated that Automatic=0.997*Manual, with a Pearson correlation coefficient of 0.999. The minimal differences between the two techniques may be explained by the fact that the hand drawn ROIs were not identical to the automatically selected ones. The average processing time was 6.7seconds in Matlab on an IntelCore2Duo processor. Conclusion: An automated image processing algorithm has been developed and validated, which will help minimize user interaction and processing time of radiochromic film used for in vivo dosimetry.« less

  4. United States Air Force Summer Research Program -- 1993 Summer Research Program Final Reports. Volume 12. Armstrong Laboratory

    DTIC Science & Technology

    1993-01-01

    Panasonic TLD . Panasonic Industrial Company; Secaucus, New Jersey. 5. Thurlow, Ronald M. "Neutron Dosimetry Using a Panasonic Thermoluminescent Dosimeter." A...steps 8-12. 29-15 THE BUILDING OF THE USAF PANASONIC UD-809AS ALGORITHM Katherine M. Arnold Research Associate Radiation Dosimetry Branch Brooks Air...Research August 1993 30-1 THE BUILDING OF THE USAF PANASONIC UD-809AS ALGORITHM Katherine M. Arnold Research Associate Radiation Dosimetry Branch

  5. A method to improve the effectiveness of diode in vivo dosimetry.

    PubMed

    Alecu, R; Alecu, M; Ochran, T G

    1998-05-01

    A routine diode in vivo dosimetry program based on a combination of entrance and exit dose measurements was clinically implemented in the radiation oncology department of Grace Hospital, Detroit, in January 1995. The delivered dose has been monitored by taking weekly measurements. The calibration of the diodes and the in vivo dosimetry protocol for this new, more effective type of dose verification is presented. The problems encountered within the program are discussed along with our solutions.

  6. Analysis of errors detected in external beam audit dosimetry program at Mexican radiotherapy centers

    NASA Astrophysics Data System (ADS)

    Álvarez-Romero, José T.; Tovar-Muñoz, Víctor M.

    2012-10-01

    Presented and analyzed are the causes of deviation observed in the pilot postal dosimetry audit program to verify the absorbed dose to water Dw in external beams of teletherapy 60Co and/or linear accelerators in Mexican radiotherapy centers, during the years 2007-2011.

  7. The IROC Houston Quality Assurance Program: Potential benefits of 3D dosimetry

    NASA Astrophysics Data System (ADS)

    Followill, D. S.; Molineu, H. A.; Lafratta, R.; Ibbott, G. S.

    2017-05-01

    The IROC Houston QA Center has provided QA core support for NCI clinical trials by ensuring that radiation doses delivered to trial patients are accurate and comparable between participating institutions. Within its QA program, IROC Houston uses anthropomorphic QA phantoms to credential sites. It is these phantoms that have the highest potential to benefit from the use of 3D dosimeters. Credentialing is performed to verify that institutions that are using advanced technologies to deliver complex treatment plans that conform to targets. This makes it increasingly difficult to assure the intended calculated dose is being delivered correctly using current techniques that are 2D-based. A 3D dosimeter such as PRESAGE® is able to provide a complete 3D measured dosimetry dataset with one treatment plan delivery. In our preliminary studies, the 3D dosimeters in our H&N and spine phantoms were found to be appropriate for remote dosimetry for relative dose measurements. To implement 3D dosimetry in IROC Houston’s phantoms, the benefit of this significant change to its current infrastructure would have to be assessed and further work would be needed before bringing 3D dosimeters into the phantom dosimetry program.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parra, Pamela Ochoa, E-mail: lapochoap@unal.edu.co; Veloza, Stella

    The radiotracer called {sup 68}Ga-labelled Glu-urea-Lys(Ahx)-HBED-CC ([68Ga]Ga-PSMA-HBED-CC) is a novel radiophar-maceutical for the detection of prostate cancer lesions by positron emission tomography (PET) imaging. Setting up a cost-effective manual synthesis of this radiotracer and making its clinical translation in Colombia will require two important elements: the evaluation of the procedure to yield a consistent product, meeting standards of radio-chemical purity and low toxicity and then, the evaluation of the radiation dosimetry. In this paper a protocol to extrapolate the biokinetic model made in normal mice to humans by using the computer software for internal dose assessment OLINDA/EXM® is presented asmore » an accurate and standardized method for the calculation of radiation dosimetry estimates.« less

  9. Commissioning dosimetry and in situ dose mapping of a semi-industrial Cobalt-60 gamma-irradiation facility using Fricke and Ceric-cerous dosimetry system and comparison with Monte Carlo simulation data

    NASA Astrophysics Data System (ADS)

    Mortuza, Md Firoz; Lepore, Luigi; Khedkar, Kalpana; Thangam, Saravanan; Nahar, Arifatun; Jamil, Hossen Mohammad; Bandi, Laxminarayan; Alam, Md Khorshed

    2018-03-01

    Characterization of a 90 kCi (3330 TBq), semi-industrial, cobalt-60 gamma irradiator was performed by commissioning dosimetry and in-situ dose mapping experiments with Ceric-cerous and Fricke dosimetry systems. Commissioning dosimetry was carried out to determine dose distribution pattern of absorbed dose in the irradiation cell and products. To determine maximum and minimum absorbed dose, overdose ratio and dwell time of the tote boxes, homogeneous dummy product (rice husk) with a bulk density of 0.13 g/cm3 were used in the box positions of irradiation chamber. The regions of minimum absorbed dose of the tote boxes were observed in the lower zones of middle plane and maximum absorbed doses were found in the middle position of front plane. Moreover, as a part of dose mapping, dose rates in the wall positions and some selective strategic positions were also measured to carry out multiple irradiation program simultaneously, especially for low dose research irradiation program. In most of the cases, Monte Carlo simulation data, using Monte Carlo N-Particle eXtended code version MCNPX 2.7., were found to be in congruence with experimental values obtained from Ceric-cerous and Fricke dosimetry; however, in close proximity positions from the source, the dose rate variation between chemical dosimetry and MCNP was higher than distant positions.

  10. A novel method for dose distribution registration using fiducial marks made by a megavoltage beam in film dosimetry for intensity-modulated radiation therapy quality assurance.

    PubMed

    Nakayama, Shinichi; Monzen, Hajime; Oonishi, Yuuichi; Mizote, Rika; Iramina, Hiraku; Kaneshige, Souichirou; Mizowaki, Takashi

    2015-06-01

    Photographic film is widely used for the dose distribution verification of intensity-modulated radiation therapy (IMRT). However, analysis for verification of the results is subjective. We present a novel method for marking the isocenter using irradiation from a megavoltage (MV) beam transmitted through slits in a multi-leaf collimator (MLC). We evaluated the effect of the marking irradiation at 500 monitor units (MU) on the total transmission through the MLC using an ionization chamber and Radiochromic Film. Film dosimetry was performed for quality assurance (QA) of IMRT plans. Three methods of registration were used for each film: marking by irradiating with an MV beam through slits in the MLC (MLC-IC); marking with a fabricated phantom (Phantom-IC); and a subjective method based on isodose lines (Manual). Each method was subjected to local γ-analysis. The effect of the marking irradiation on the total transmission was 0.16%, as measured by a ionization chamber at a 10-cm depth in a solid phantom, while the inter-leaf transmission was 0.3%, determined from the film. The mean pass rates for each registration method agreed within ± 1% when the criteria used were a distance-to-agreement (DTA) of 3 mm and a dose difference (DD) of 3%. For DTA/DD criteria of 2mm/3%, the pass rates in the sagittal plane were 96.09 ± 0.631% (MLC-IC), 96.27 ± 0.399% (Phantom-IC), and 95.62 ± 0.988% (Manual). The present method is a versatile and useful method of improving the objectivity of film dosimetry for IMRT QA. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. A parameterization method and application in breast tomosynthesis dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2013-09-15

    Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized usingmore » a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.« less

  12. 20170915 - EPA’s Rapid Exposure and Dosimetry Project (Alberta Health)

    EPA Science Inventory

    The Chemical Safety for Sustainability Research Program includes the Rapid Exposure and Dosimetry (RED) project. RED advances high throughput research in exposure modeling and toxicokinetics. This presentation is an overview of publicly available tools developed by the RED projec...

  13. Type Testing of Model 7200 Automatic TLD Reader.

    PubMed

    Malek Mohammadi, M; Hosseini Pooya, S M

    2017-04-20

    The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Mathematics in medicine: tumor detection, radiation dosimetry, and simulation in psychotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bellman, R.; Kashef, B.; Smith, C.P.

    1975-05-01

    Work done in the application of mathematics to medicine over the last 20 years is briefly reviewed. Scan-rescan processes, radiation dosimetry, and medical interviewing are discussed. The first uses dynamic programming, the second invariant imbedding, and the third simulation. (ACR)

  15. Interagency Dosimetry Project: Methods for Dosimetry Adjustment Based on Mode of Action

    EPA Science Inventory

    As the science of toxicology evolves, many laboratories are adding new testing protocols or assays in their programs directed at ascertaining mechanistic information on uptake and toxic action of chemicals. In response to the increasing complexity and comprehensiveness of these ...

  16. Creation of two tomographic voxel models of paediatric patients in the first year of life

    NASA Astrophysics Data System (ADS)

    Nipper, J. C.; Williams, J. L.; Bolch, W. E.

    2002-09-01

    Tomographic computational models, based on regional segmentation of CT or MRI medical images, have increasingly been proposed as replacements for current stylized mathematical models of human anatomy used in radiation dosimetry studies. While much effort has been devoted towards the creation of adult models, few research studies have been initiated to address the need for models supporting paediatric radiology dosimetry. In this study, two tomographic models were created using a combination of automatic and manual segmentation via a program created in-house using IDL version 5.5. The first model is of a normal 6 day female newborn, and consists of a 512 × 512 × 485 data array. The CT slices of this model were obtained every 1 mm, and 66 different anatomic regions were defined. The second model is of a patient developmentally equivalent to a 2 month male, and was saved as a 512 × 512 × 438 data array. This subject had severe tissue oedema within the gut, kidneys, liver and spleen. The model is thus considered representative of a critically ill child, from a patient subpopulation expected to receive a larger than normal number of diagnostic x-ray exams. The voxel volumes for the two models are 0.35 mm3 and 0.30 mm3, respectively, thus making these models the most detailed in existence for paediatric dosimetry applications. Ratios of organ masses for the UF newborn model to those within the reference ORNL/MIRD model range from highs of 1.2 to 1.7 for the oesophagus and small intestine/colon, respectively, to lows of 0.18 to 0.27 for the mandible and humeri, respectively. For the UF 2 month model, ratios of organ masses in the UF model to those in the 8 week GSF BABY model ranged from highs of 3.7 to 5.2 for the clavicles and spleen, respectively, to lows of 0.2 to 0.3 for the adrenals and scapulae, respectively.

  17. JADA: a graphical user interface for comprehensive internal dose assessment in nuclear medicine.

    PubMed

    Grimes, Joshua; Uribe, Carlos; Celler, Anna

    2013-07-01

    The main objective of this work was to design a comprehensive dosimetry package that would keep all aspects of internal dose calculation within the framework of a single software environment and that would be applicable for a variety of dose calculation approaches. Our MATLAB-based graphical user interface (GUI) can be used for processing data obtained using pure planar, pure SPECT, or hybrid planar/SPECT imaging. Time-activity data for source regions are obtained using a set of tools that allow the user to reconstruct SPECT images, load images, coregister a series of planar images, and to perform two-dimensional and three-dimensional image segmentation. Curve fits are applied to the acquired time-activity data to construct time-activity curves, which are then integrated to obtain time-integrated activity coefficients. Subsequently, dose estimates are made using one of three methods. The organ level dose calculation subGUI calculates mean organ doses that are equivalent to dose assessment performed by OLINDA/EXM. Voxelized dose calculation options, which include the voxel S value approach and Monte Carlo simulation using the EGSnrc user code DOSXYZnrc, are available within the process 3D image data subGUI. The developed internal dosimetry software package provides an assortment of tools for every step in the dose calculation process, eliminating the need for manual data transfer between programs. This saves times and minimizes user errors, while offering a versatility that can be used to efficiently perform patient-specific internal dose calculations in a variety of clinical situations.

  18. WE-H-207A-07: Image-Based Versus Atlas-Based Internal Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fallahpoor, M; Abbasi, M; Parach, A

    Purpose: Monte Carlo (MC) simulation is known as the gold standard method for internal dosimetry. It requires radionuclide distribution from PET or SPECT and body structure from CT for accurate dose calculation. The manual or semi-automatic segmentation of organs from CT images is a major obstacle. The aim of this study is to compare the dosimetry results based on patient’s own CT and a digital humanoid phantom as an atlas with pre-specified organs. Methods: SPECT-CT images of a 50 year old woman who underwent bone pain palliation with Samarium-153 EDTMP for osseous metastases from breast cancer were used. The anatomicalmore » date and attenuation map were extracted from SPECT/CT and three XCAT digital phantoms with different BMIs (i.e. matched (38.8) and unmatched (35.5 and 36.7) with patient’s BMI that was 38.3). Segmentation of patient’s organs in CT image was performed using itk-SNAP software. GATE MC Simulator was used for dose calculation. Specific absorbed fractions (SAFs) and S-values were calculated for the segmented organs. Results: The differences between SAFs and S-values are high using different anatomical data and range from −13% to 39% for SAF values and −109% to 79% for S-values in different organs. In the spine, the clinically important target organ for Samarium Therapy, the differences in the S-values and SAF values are higher between XCAT phantom and CT when the phantom with identical BMI is employed (53.8% relative difference in S-value and 26.8% difference in SAF). However, the whole body dose values were the same between the calculations based on the CT and XCAT with different BMIs. Conclusion: The results indicated that atlas-based dosimetry using XCAT phantom even with matched BMI for patient leads to considerable errors as compared to image-based dosimetry that uses the patient’s own CT Patient-specific dosimetry using CT image is essential for accurate results.« less

  19. Dosimetry and prescription in liver radioembolization with 90Y microspheres: 3D calculation of tumor-to-liver ratio from global 99mTc-MAA SPECT information

    NASA Astrophysics Data System (ADS)

    Mañeru, Fernando; Abós, Dolores; Bragado, Laura; Fuentemilla, Naiara; Caudepón, Fernando; Pellejero, Santiago; Miquelez, Santiago; Rubio, Anastasio; Goñi, Elena; Hernández-Vitoria, Araceli

    2017-12-01

    Dosimetry in liver radioembolization with 90Y microspheres is a fundamental tool, both for the optimization of each treatment and for improving knowledge of the treatment effects in the tissues. Different options are available for estimating the administered activity and the tumor/organ dose, among them the so-called partition method. The key factor in the partition method is the tumor/normal tissue activity uptake ratio (T/N), which is obtained by a single-photon emission computed tomography (SPECT) scan during a pre-treatment simulation. The less clear the distinction between healthy and tumor parenchyma within the liver, the more difficult it becomes to estimate the T/N ratio; therefore the use of the method is limited. This study presents a methodology to calculate the T/N ratio using global information from the SPECT. The T/N ratio is estimated by establishing uptake thresholds consistent with previously performed volumetry. This dose calculation method was validated against 3D voxel dosimetry, and was also compared with the standard partition method based on freehand regions of interest (ROI) outlining on SPECT slices. Both comparisons were done on a sample of 20 actual cases of hepatocellular carcinoma treated with resin microspheres. The proposed method and the voxel dosimetry method yield similar results, while the ROI-based method tends to over-estimate the dose to normal tissues. In addition, the variability associated with the ROI-based method is more extreme than the other methods. The proposed method is simpler than either the ROI or voxel dosimetry approaches and avoids the subjectivity associated with the manual selection of regions.

  20. Neutron Exposure Parameters for the Dosimetry Capsule in the Heavy-Section Steel Irradiation Program Tenth Irradiation Series

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C.A. Baldwin; F.B.K. Kam; I. Remec

    1998-10-01

    This report describes the computational methodology for the least-squares adjustment of the dosimetry data from the HSSI 10.OD dosimetry capsule with neutronics calculations. It presents exposure rates at each dosimetry location for the neutron fluence greater than 1.0 MeV, fluence greater than 0.1 MeV, and displacements per atom. Exposure parameter distributions are also described in terms of three- dimensional fitting functions. When fitting functions are used it is suggested that an uncertainty of 6% (1 o) should be associated with the exposure rate values. The specific activity of each dosimeter at the end of irradiation is listed in the Appendix.

  1. 76 FR 38550 - Technical Standard DOE-STD-1095-2011, Department of Energy Laboratory Accreditation for External...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-01

    ... Laboratory Accreditation for External Dosimetry AGENCY: Office of Health, Safety and Security, Department of... Department) is issuing Technical Standard DOE-STD-1095-2011, Department of Energy Laboratory Accreditation... part, to determine whether to accredit dosimetry programs in accordance with the DOE Laboratory...

  2. Hanford radiological protection support services annual report for 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyon, M.; Bihl, D.E.; Fix, J.J.

    1995-06-01

    Various Hanford Site radiation protection services provided by the Pacific Northwest Laboratory for the US Department of Energy Richland Operations Office and Hanford contractors are described in this annual report for the calendar year 1994. These activities include external dosimetry measurements and evaluations, internal dosimetry measurements and evaluations, in vivo measurements, radiological record keeping, radiation source calibration, and instrument calibration and evaluation. For each of these activities, the routine program and any program changes or enhancements are described, as well as associated tasks, investigations, and studies. Program- related publications, presentations, and other staff professional activities are also described.

  3. Hanford radiological protection support services. Annual report for 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyon, M.; Bihl, D.E.; Carbaugh, E.H.

    1996-05-01

    Various Hanford Site radiation protection services provided by the Pacific Northwest National Laboratory for the U.S. Department of Energy Richland Operations Office and Hanford contractors are described in this annual report for calendar year 1995. These activities include external dosimetry measurements and evaluations, internal dosimetry measurements and evaluations, in vivo measurements, radiological record keeping, radiation source calibration, and instrument calibration and evaluation. For each of these activities, the routine program and any program changes or enhancements are described, as well as associated tasks, investigations, and studies. Program-related publications, presentations, and other staff professional activities are also described.

  4. Experimental active and passive dosimetry systems for the NASA Skylab program

    NASA Technical Reports Server (NTRS)

    Schneider, M. F.; Janni, J. F.; Ainsworth, G. C.

    1972-01-01

    Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis.

  5. Guidelines on the implementation of diode in vivo dosimetry programs for photon and electron external beam therapy.

    PubMed

    Alecu, R; Loomis, T; Alecu, J; Ochran, T

    1999-01-01

    Semiconductor diodes offer many advantages for clinical dosimetry: high sensitivity, real-time readout, simple instrumentation, robustness and air pressure independence. The feasibility and usefulness of in vivo dosimetry with diodes has been shown by numerous publications, but very few, if any, refer to the utilization of diodes in electron beam dosimetry. The purpose of this paper is to present our methods for implementing an effective IVD program for external beam therapy with photons and electrons and to evaluate a new type of diodes. Methods of deciding on reasonable action levels along with calibration procedures, established according to the type of measurements intended to be performed and the action limits, are discussed. Correction factors to account for nonreference clinical conditions for new types of diodes (designed for photon and electron beams) are presented and compared with those required by older models commercially available. The possibilities and limitations of each type of diode are presented, emphasizing the importance of using the appropriate diode for each task and energy range.

  6. The stability of liquid-filled matrix ionization chamber electronic portal imaging devices for dosimetry purposes.

    PubMed

    Louwe, R J W; Tielenburg, R; van Ingen, K M; Mijnheer, B J; van Herk, M B

    2004-04-01

    This study was performed to determine the stability of liquid-filled matrix ionization chamber (LiFi-type) electronic portal imaging devices (EPID) for dosimetric purposes. The short- and long-term stability of the response was investigated, as well as the importance of factors influencing the response (e.g., temperature fluctuations, radiation damage, and the performance of the electronic hardware). It was shown that testing the performance of the electronic hardware as well as the short-term stability of the imagers may reveal the cause of a poor long-term stability of the imager response. In addition, the short-term stability was measured to verify the validity of the fitted dose-response curve immediately after beam startup. The long-term stability of these imagers could be considerably improved by correcting for room temperature fluctuations and gradual changes in response due to radiation damage. As a result, the reproducibility was better than 1% (1 SD) over a period of two years. The results of this study were used to formulate recommendations for a quality control program for portal dosimetry. The effect of such a program was assessed by comparing the results of portal dosimetry and in vivo dosimetry using diodes during the treatment of 31 prostate patients. The improvement of the results for portal dosimetry was consistent with the deviations observed with the reproducibility tests in that particular period. After a correction for the variation in response of the imager, the average difference between the measured and prescribed dose during the treatment of prostate patients was -0.7%+/-1.5% (1 SD), and -0.6%+/-1.1% (1 SD) for EPID and diode in vivo dosimetry, respectively. It can be concluded that a high stability of the response can be achieved for this type of EPID by applying a rigorous quality control program.

  7. The Impact of Manual Segmentation of CT Images on Monte Carlo Based Skeletal Dosimetry

    NASA Astrophysics Data System (ADS)

    Frederick, Steve; Jokisch, Derek; Bolch, Wesley; Shah, Amish; Brindle, Jim; Patton, Phillip; Wyler, J. S.

    2004-11-01

    Radiation doses to the skeleton from internal emitters are of importance in both protection of radiation workers and patients undergoing radionuclide therapies. Improved dose estimates involve obtaining two sets of medical images. The first image provides the macroscopic boundaries (spongiosa volume and cortical shell) of the individual skeletal sites. A second, higher resolution image of the spongiosa microstructure is also obtained. These image sets then provide the geometry for a Monte Carlo radiation transport code. Manual segmentation of the first image is required in order to provide the macrostructural data. For this study, multiple segmentations of the same CT image were performed by multiple individuals. The segmentations were then used in the transport code and the results compared in order to determine the impact of differing segmentations on the skeletal doses. This work has provided guidance on the extent of training required of the manual segmenters. (This work was supported by a grant from the National Institute of Health.)

  8. Assessment of national dosimetry quality audits results for teletherapy machines from 1989 to 2015.

    PubMed

    Muhammad, Wazir; Ullah, Asad; Mahmood, Khalid; Matiullah

    2016-01-01

    The purpose of this study was to ensure accuracy in radiation dose delivery, external dosimetry quality audit has an equal importance with routine dosimetry performed at clinics. To do so, dosimetry quality audit was organized by the Secondary Standard Dosimetry Laboratory (SSDL) of Pakistan Institute of Nuclear Science and Technology (PINSTECH) at the national level to investigate and minimize uncertainties involved in the measurement of absorbed dose, and to improve the accuracy of dose measurement at different radiotherapy hospitals. A total of 181 dosimetry quality audits (i.e., 102 of Co-60 and 79 of linear accelerators) for teletherapy units installed at 22 different sites were performed from 1989 to 2015. The percent deviation between users’ calculated/stated dose and evaluated dose (in the result of on-site dosimetry visits) were calculated and the results were analyzed with respect to the limits of ± 2.5% (ICRU "optimal model") ± 3.0% (IAEA on-site dosimetry visits limit) and ± 5.0% (ICRU minimal or "lowest acceptable" model). The results showed that out of 181 total on-site dosimetry visits, 20.44%, 16.02%, and 4.42% were out of acceptable limits of ± 2.5% ± 3.0%, and ± 5.0%, respectively. The importance of a proper ongoing quality assurance program, recommendations of the followed protocols, and properly calibrated thermometers, pressure gauges, and humidity meters at radiotherapy hospitals are essential in maintaining consistency and uniformity of absorbed dose measurements for precision in dose delivery.

  9. The NASTRAN theoretical manual (level 16.0)

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The manual is a commentary on the NASTRAN computer program, introducing the program to all interested persons. The manual's most important function is to present the developments of the analytical and numerical procedures that underlie the program. This manual is one of the four manuals which document the NASTRAN computer program.

  10. Korean standard nuclear plant ex-vessel neutron dosimetry program Ulchin 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duo, J.I.; Chen, J.; Kulesza, J.A.

    2011-07-01

    A comprehensive ex-vessel neutron dosimetry (EVND) surveillance program has been deployed in 16 pressurized water reactors (PWR) in South Korea and EVND dosimetry sets have already been installed and analyzed in Westinghouse reactor designs. In this paper, the unique features of the design, training, and installation in the Korean standard nuclear plant (KSNP) Ulchin Unit 4 are presented. Ulchin Unit 4 Cycle 9 represents the first dosimetry analyzed from the EVND design deployed in KSNP plants: Yonggwang Units 3 through 6 and Ulchin Units 3 through 6. KSNP's cavity configuration precludes a conventional installation from the cavity floor. The solution,more » requiring the installation crew to access the cavity at an elevation of the active core, places a premium on rapid installation due to high area dose rates. Numerous geometrical features warranted the use of a detailed design in true 3D mechanical design software to control interferences. A full-size training mockup maximized the crew ability to correctly install the instrument in minimum time. The analysis of the first dosimetry set shows good agreements between measurement and calculation within the associated uncertainties. A complete EVND system has been successfully designed, installed, and analyzed for a KNSP plant. Current and future EVND analyses will continue supporting the successful operation of PWR units in South Korea. (authors)« less

  11. Effect of processor temperature on film dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srivastava, Shiv P.; Das, Indra J., E-mail: idas@iupui.edu

    2012-07-01

    Optical density (OD) of a radiographic film plays an important role in radiation dosimetry, which depends on various parameters, including beam energy, depth, field size, film batch, dose, dose rate, air film interface, postexposure processing time, and temperature of the processor. Most of these parameters have been studied for Kodak XV and extended dose range (EDR) films used in radiation oncology. There is very limited information on processor temperature, which is investigated in this study. Multiple XV and EDR films were exposed in the reference condition (d{sub max.}, 10 Multiplication-Sign 10 cm{sup 2}, 100 cm) to a given dose. Anmore » automatic film processor (X-Omat 5000) was used for processing films. The temperature of the processor was adjusted manually with increasing temperature. At each temperature, a set of films was processed to evaluate OD at a given dose. For both films, OD is a linear function of processor temperature in the range of 29.4-40.6 Degree-Sign C (85-105 Degree-Sign F) for various dose ranges. The changes in processor temperature are directly related to the dose by a quadratic function. A simple linear equation is provided for the changes in OD vs. processor temperature, which could be used for correcting dose in radiation dosimetry when film is used.« less

  12. Hanford Technical Basis for Multiple Dosimetry Effective Dose Methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, Robin L.; Rathbone, Bruce A.

    2010-08-01

    The current method at Hanford for dealing with the results from multiple dosimeters worn during non-uniform irradiation is to use a compartmentalization method to calculate the effective dose (E). The method, as documented in the current version of Section 6.9.3 in the 'Hanford External Dosimetry Technical Basis Manual, PNL-MA-842,' is based on the compartmentalization method presented in the 1997 ANSI/HPS N13.41 standard, 'Criteria for Performing Multiple Dosimetry.' With the adoption of the ICRP 60 methodology in the 2007 revision to 10 CFR 835 came changes that have a direct affect on the compartmentalization method described in the 1997 ANSI/HPS N13.41more » standard, and, thus, to the method used at Hanford. The ANSI/HPS N13.41 standard committee is in the process of updating the standard, but the changes to the standard have not yet been approved. And, the drafts of the revision of the standard tend to align more with ICRP 60 than with the changes specified in the 2007 revision to 10 CFR 835. Therefore, a revised method for calculating effective dose from non-uniform external irradiation using a compartmental method was developed using the tissue weighting factors and remainder organs specified in 10 CFR 835 (2007).« less

  13. Specific issues in small animal dosimetry and irradiator calibration

    PubMed Central

    Yoshizumi, Terry; Brady, Samuel L.; Robbins, Mike E.; Bourland, J. Daniel

    2013-01-01

    Purpose In response to the increased risk of radiological terrorist attack, a network of Centers for Medical Countermeasures against Radiation (CMCR) has been established in the United States, focusing on evaluating animal model responses to uniform, relatively homogenous whole- or partial-body radiation exposures at relatively high dose rates. The success of such studies is dependent not only on robust animal models but on accurate and reproducible dosimetry within and across CMCR. To address this issue, the Education and Training Core of the Duke University School of Medicine CMCR organised a one-day workshop on small animal dosimetry. Topics included accuracy in animal dosimetry accuracy, characteristics and differences of cesium-137 and X-ray irradiators, methods for dose measurement, and design of experimental irradiation geometries for uniform dose distributions. This paper summarises the information presented and discussed. Conclusions Without ensuring accurate and reproducible dosimetry the development and assessment of the efficacy of putative countermeasures will not prove successful. Radiation physics support is needed, but is often the weakest link in the small animal dosimetry chain. We recommend: (i) A user training program for new irradiator users, (ii) subsequent training updates, and (iii) the establishment of a national small animal dosimetry center for all CMCR members. PMID:21961967

  14. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging.

    PubMed

    Persson, Morten; El Ali, Henrik H; Binderup, Tina; Pfeifer, Andreas; Madsen, Jacob; Rasmussen, Palle; Kjaer, Andreas

    2014-03-01

    (64)Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET studies in mice to evaluate the in vivo biodistribution and estimate human dosimetry of (64)Cu-DOTA-AE105. Five mice received iv tail injection of (64)Cu-DOTA-AE105 and were PET/CT scanned 1, 4.5 and 22 h post injection. Volume-of-interest (VOI) were manually drawn on the following organs: heart, lung, liver, kidney, spleen, intestine, muscle, bone and bladder. The activity concentrations in the mentioned organs [%ID/g] were used for the dosimetry calculation. The %ID/g of each organ at 1, 4.5 and 22 h was scaled to human value based on a difference between organ and body weights. The scaled values were then exported to OLINDA software for computation of the human absorbed doses. The residence times as well as effective dose equivalent for male and female could be obtained for each organ. To validate this approach, of human projection using mouse data, five mice received iv tail injection of another (64)Cu-DOTA peptide-based tracer, (64)Cu-DOTA-TATE, and underwent same procedure as just described. The human dosimetry estimates were then compared with observed human dosimetry estimate recently found in a first-in-man study using (64)Cu-DOTA-TATE. Human estimates of (64)Cu-DOTA-AE105 revealed the heart wall to receive the highest dose (0.0918 mSv/MBq) followed by the liver (0.0815 mSv/MBq), All other organs/tissue were estimated to receive doses in the range of 0.02-0.04 mSv/MBq. The mean effective whole-body dose of (64)Cu-DOTA-AE105 was estimated to be 0.0317 mSv/MBq. Relatively good correlation between human predicted and observed dosimetry estimates for (64)Cu-DOTA-TATE was found. Importantly, the effective whole body dose was predicted with very high precision (predicted value: 0.0252 mSv/Mbq, Observed value: 0.0315 mSv/MBq) thus validating our approach for human dosimetry estimation. Favorable dosimetry estimates together with previously reported uPAR PET data fully support human testing of (64)Cu-DOTA-AE105. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Implementation of an intraoperative electron radiotherapy in vivo dosimetry program.

    PubMed

    López-Tarjuelo, Juan; Morillo-Macías, Virginia; Bouché-Babiloni, Ana; Boldó-Roda, Enrique; Lozoya-Albacar, Rafael; Ferrer-Albiach, Carlos

    2016-03-15

    Intraoperative electron radiotherapy (IOERT) is a highly selective radiotherapy technique which aims to treat restricted anatomic volumes during oncological surgery and is now the subject of intense re-evaluation. In vivo dosimetry has been recommended for IOERT and has been identified as a risk-reduction intervention in the context of an IOERT risk analysis. Despite reports of fruitful experiences, information about in vivo dosimetry in intraoperative radiotherapy is somewhat scarce. Therefore, the aim of this paper is to report our experience in developing a program of in vivo dosimetry for IOERT, from both multidisciplinary and practical approaches, in a consistent patient series. We also report several current weaknesses. Reinforced TN-502RDM-H mobile metal oxide semiconductor field effect transistors (MOSFETs) and Gafchromic MD-55-2 films were used as a redundant in vivo treatment verification system with an Elekta Precise fixed linear accelerator for calibrations and treatments. In vivo dosimetry was performed in 45 patients in cases involving primary tumors or relapses. The most frequent primary tumors were breast (37 %) and colorectal (29 %), and local recurrences among relapses was 83 %. We made 50 attempts to measure with MOSFETs and 48 attempts to measure with films in the treatment zones. The surgical team placed both detectors with supervision from the radiation oncologist and following their instructions. The program was considered an overall success by the different professionals involved. The absorbed doses measured with MOSFETs and films were 93.8 ± 6.7 % and 97.9 ± 9.0 % (mean ± SD) respectively using a scale in which 90 % is the prescribed dose and 100 % is the maximum absorbed dose delivered by the beam. However, in 10 % of cases we experienced dosimetric problems due to detector misalignment, a situation which might be avoided with additional checks. The useful MOSFET lifetime length and the film sterilization procedure should also be controlled. It is feasible to establish an in vivo dosimetry program for a wide set of locations treated with IOERT using a multidisciplinary approach according to the skills of the professionals present and the detectors used; oncological surgeons' commitment is key to success in this context. Films are more unstable and show higher uncertainty than MOSFETs but are cheaper and are useful and convenient if real-time treatment monitoring is not necessary.

  16. DOE standard: The Department of Energy Laboratory Accreditation Program for radiobioassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP) for Radiobioassay, for use by the US Department of Energy (DOE) and DOE Contractor radiobioassay programs. This standard is intended to be used in conjunction with the general administrative technical standard that describes the overall DOELAP accreditation process--DOE-STD-1111-98, Department of Energy Laboratory Accreditation Program Administration. This technical standard pertains to radiobioassay service laboratories that provide either direct or indirect (in vivo or in vitro) radiobioassay measurements in support of internal dosimetry programs at DOE facilities or for DOE and DOE contractors. Similar technical standards have been developedmore » for other DOELAP dosimetry programs. This program consists of providing an accreditation to DOE radiobioassay programs based on successful completion of a performance-testing process and an on-site evaluation by technical experts. This standard describes the technical requirements and processes specific to the DOELAP Radiobioassay Accreditation Program as required by 10 CFR 835 and as specified generically in DOE-STD-1111-98.« less

  17. MO-D-BRB-02: The Radiological Physics Center's Quality Audit Program: Where Can We Improve?

    PubMed

    Followill, D; Lowenstein, J; Molineu, A; Alvarez, P; Aguirre, J; Kry, S; Summers, P; Ibbott, G

    2012-06-01

    To analyze the findings of the Radiological Physics Center's (RPC) QA audits of institutions participating in NCI sponsored clinical trials. The RPC has developed an extensive Quality Assurance (QA) program over the past 44 years. This program includes on-site dosimetry reviews where measurements on therapy machines are made, records are reviewed and personnel are interviewed. The program's remote audit tools include mailed dosimeters (OSLD/TLD) to verify output calibration, comparison of dosimetry data with RPC 'standard' data, evaluation of benchmark and patient calculations to verify the treatment planning algorithms, review of institution's QA procedures and records, and use of anthropomorphic phantoms to verify tumor dose delivery. The RPC endeavors to assist institutions in finding the origins of any detected discrepancies, and to resolve them. Ninety percent of institutions receiving dosimetry recommendations has remained level for the past 5 years. The most frequent recommendations were for not performing TG-40 QA tests, wedge factors, small field size output factors and off-axis factors. Since TG-51 was published, the number of beam calibrations audited during visits with ion chambers, that met the RPC's ±3% criterion, decreased initially but has risen to pre-TG-51 levels. The OSLD/TLD program shows that only ∼3% of the beams are outside our ±5% criteria, but these discrepancies are distributed over 12-20% of the institutions. The percent of institutions with ï, 3 l beam outside the RPC's criteria is approximately the same whether OSLD/TLD or ion chambers were used. The first time passing rate for the anthropomorphic phantoms is increasing with time. The prostate phantom has the highest pass rate while the spine phantom has the lowest. Numerous dosimetry errors continue to be discovered by the RPC's QA program and the RPC continues to play an important role in helping institutions resolve these errors. This work was supported by PHS grants CA10953 and CA081647 awarded by NCI. © 2012 American Association of Physicists in Medicine.

  18. Books and Pets: Our Friends for Life! Arizona Reading Program Manual.

    ERIC Educational Resources Information Center

    Arizona State Dept. of Library, Archives and Public Records, Phoenix.

    This reading program manual delineates the "Books and Pets" program, a project of Arizona Reads, which is a collaboration between the Arizona Humanities Council and the Arizona State Library, Archives, and Public Records. A CD-ROM version of the program accompanies the manual. The manual is divided into the following parts: Introduction;…

  19. Deformable registration of x-ray to MRI for post-implant dosimetry in prostate brachytherapy

    NASA Astrophysics Data System (ADS)

    Park, Seyoun; Song, Danny Y.; Lee, Junghoon

    2016-03-01

    Post-implant dosimetric assessment in prostate brachytherapy is typically performed using CT as the standard imaging modality. However, poor soft tissue contrast in CT causes significant variability in target contouring, resulting in incorrect dose calculations for organs of interest. CT-MR fusion-based approach has been advocated taking advantage of the complementary capabilities of CT (seed identification) and MRI (soft tissue visibility), and has proved to provide more accurate dosimetry calculations. However, seed segmentation in CT requires manual review, and the accuracy is limited by the reconstructed voxel resolution. In addition, CT deposits considerable amount of radiation to the patient. In this paper, we propose an X-ray and MRI based post-implant dosimetry approach. Implanted seeds are localized using three X-ray images by solving a combinatorial optimization problem, and the identified seeds are registered to MR images by an intensity-based points-to-volume registration. We pre-process the MR images using geometric and Gaussian filtering. To accommodate potential soft tissue deformation, our registration is performed in two steps, an initial affine transformation and local deformable registration. An evolutionary optimizer in conjunction with a points-to-volume similarity metric is used for the affine registration. Local prostate deformation and seed migration are then adjusted by the deformable registration step with external and internal force constraints. We tested our algorithm on six patient data sets, achieving registration error of (1.2+/-0.8) mm in < 30 sec. Our proposed approach has the potential to be a fast and cost-effective solution for post-implant dosimetry with equivalent accuracy as the CT-MR fusion-based approach.

  20. NASTRAN user's guide (Level 17.5)

    NASA Technical Reports Server (NTRS)

    Field, E. I.; Herting, D. N.; Morgan, M. J.

    1979-01-01

    The user's guide is a handbook for engineers and analysts who use the NASTRAN finite element computer program supplements the NASTRAN Theoretical Manual (NASA SP-221), the NASTRAN User's Manual (NASA SP-222), the NASTRAN Programmer's Manual (NASA SP-223), and the NASTRAN Demonstration Program Manual (NASA SP-224). It provides modeling hints, attributes of the program, and references to the four manuals listed.

  1. Radiological and microwave Protection at NRL, January - December 1983

    DTIC Science & Technology

    1984-06-27

    reduced to background. 18 Surveys with TLD badges were made on pulsed electron beam machines in Buildings 101 and A68 throughout the year. The Gamble...calibration of radiation dosimetry systems required by the Laboratory’s radiological safety program, or by other Laboratory or Navy groups. The Section...provides consultation and assistance on dosimetry problems to the Staff, Laboratory, and Navy. The Section maintains and calibrates fixed-field radiac

  2. LWR pressure vessel surveillance dosimetry improvement program: LWR power reactor surveillance physics-dosimetry data base compendium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McElroy, W.N.

    1985-08-01

    This NRC physics-dosimetry compendium is a collation of information and data developed from available research and commercial light water reactor vessel surveillance program (RVSP) documents and related surveillance capsule reports. The data represents the results of the HEDL least-squares FERRET-SAND II Code re-evaluation of exposure units and values for 47 PWR and BWR surveillance capsules for W, B and W, CE, and GE power plants. Using a consistent set of auxiliary data and dosimetry-adjusted reactor physics results, the revised fluence values for E > 1 MeV averaged 25% higher than the originally reported values. The range of fluence values (new/old)more » was from a low of 0.80 to a high of 2.38. These HEDL-derived FERRET-SAND II exposure parameter values are being used for NRC-supported HEDL and other PWR and BWR trend curve data development and testing studies. These studies are providing results to support Revision 2 of Regulatory Guide 1.99. As stated by Randall (Ra84), the Guide is being updated to reflect recent studies of the physical basis for neutron radiation damage and efforts to correlate damage to chemical composition and fluence.« less

  3. CytoBayesJ: software tools for Bayesian analysis of cytogenetic radiation dosimetry data.

    PubMed

    Ainsbury, Elizabeth A; Vinnikov, Volodymyr; Puig, Pedro; Maznyk, Nataliya; Rothkamm, Kai; Lloyd, David C

    2013-08-30

    A number of authors have suggested that a Bayesian approach may be most appropriate for analysis of cytogenetic radiation dosimetry data. In the Bayesian framework, probability of an event is described in terms of previous expectations and uncertainty. Previously existing, or prior, information is used in combination with experimental results to infer probabilities or the likelihood that a hypothesis is true. It has been shown that the Bayesian approach increases both the accuracy and quality assurance of radiation dose estimates. New software entitled CytoBayesJ has been developed with the aim of bringing Bayesian analysis to cytogenetic biodosimetry laboratory practice. CytoBayesJ takes a number of Bayesian or 'Bayesian like' methods that have been proposed in the literature and presents them to the user in the form of simple user-friendly tools, including testing for the most appropriate model for distribution of chromosome aberrations and calculations of posterior probability distributions. The individual tools are described in detail and relevant examples of the use of the methods and the corresponding CytoBayesJ software tools are given. In this way, the suitability of the Bayesian approach to biological radiation dosimetry is highlighted and its wider application encouraged by providing a user-friendly software interface and manual in English and Russian. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. California Publicly-Owned Utilities (POUs) – LBNL ‘Beyond Widgets’ Project. Task: ambient lighting and occupancy-based plug load control. System Program Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, Alastair; Mathew, Paul A.; Regnier, Cynthia

    This program manual contains detailed technical information for implementing an incentive program for task-ambient lighting and occupancy-based plug load control. This manual was developed by Lawrence Berkeley National Laboratory, in collaboration with the California Publicly-Owned Utilities (CA POUs) as a partner in the ‘Beyond Widgets’ program funded by the U.S. Department of Energy Building Technologies Office. The primary audience for this manual is the program staff of the various CA POUs. It may also be used by other utility incentive programs to help develop similar programs. It is anticipated that the content of this manual be utilized by the CAmore » POU staff for developing related documents such as the Technical Resource Manual and other filings pertaining to the rollout of an energy systems-based rebate incentive program.« less

  5. An evaluation toolkit for Florida's Commuter Assistance Programs (CAP) : a companion to the 1999 CAP evaluation manual

    DOT National Transportation Integrated Search

    2001-01-01

    This manual is a companion piece to the Commuter Assistance Program Evaluation Manual that was developed to assist Florida's Commuter Assistance Programs (CAP) in their efforts to measure and evaluate their performance. This manual is intended to pro...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, C

    Purpose: To implement a novel, automatic, institutional customizable DVH quantities evaluation and PDF report tool on Philips Pinnacle treatment planning system (TPS) Methods: An add-on program (P3DVHStats) is developed by us to enable automatic DVH quantities evaluation (including both volume and dose based quantities, such as V98, V100, D2), and automatic PDF format report generation, for EMR convenience. The implementation is based on a combination of Philips Pinnacle scripting tool and Java language pre-installed on each Pinnacle Sun Solaris workstation. A single Pinnacle script provide user a convenient access to the program when needed. The activated script will first exportmore » DVH data for user selected ROIs from current Pinnacle plan trial; a Java program then provides a simple GUI interface, utilizes the data to compute any user requested DVH quantities, compare with preset institutional DVH planning goals; if accepted by users, the program will also generate a PDF report of the results and export it from Pinnacle to EMR import folder via FTP. Results: The program was tested thoroughly and has been released for clinical use at our institution (Pinnacle Enterprise server with both thin clients and P3PC access), for all dosimetry and physics staff, with excellent feedback. It used to take a few minutes to use MS-Excel worksheet to calculate these DVH quantities for IMRT/VMAT plans, and manually save them as PDF report; with the new program, it literally takes a few mouse clicks in less than 30 seconds to complete the same tasks. Conclusion: A Pinnacle scripting and Java language based program is successfully implemented, customized to our institutional needs. It is shown to dramatically reduce time and effort needed for DVH quantities computing and EMR reporting.« less

  7. In-Home Respite Care Program Development. Background. Coordinator's Manual. Training Manual.

    ERIC Educational Resources Information Center

    Parham, J. D.; And Others

    This volume consists of a background discussion, coordinator's manual, and training manual dealing with developing programs for the in-home respite care (IHRC) of the developmentally disabled. Addressed in the background information unit are the nature of developmental disabilities; program variables, planning, and funding; and practical…

  8. Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: Results of IAEA multi-center studies

    PubMed Central

    Izewska, Joanna; Wesolowska, Paulina; Azangwe, Godfrey; Followill, David S.; Thwaites, David I.; Arib, Mehenna; Stefanic, Amalia; Viegas, Claudio; Suming, Luo; Ekendahl, Daniela; Bulski, Wojciech; Georg, Dietmar

    2016-01-01

    Abstract The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP ‘Development of Quality Audits for Radiotherapy Dosimetry for Complex Treatment Techniques’ was conducted in 2009–2012 as an extension of previously developed audit programs. Material and methods. The CRP work described in this paper focused on developing and testing two steps of dosimetry audit: verification of heterogeneity corrections, and treatment planning system (TPS) modeling of small MLC fields, which are important for the initial stages of complex radiation treatments, such as IMRT. The project involved development of a new solid slab phantom with heterogeneities containing special measurement inserts for thermoluminescent dosimeters (TLD) and radiochromic films. The phantom and the audit methodology has been developed at the IAEA and tested in multi-center studies involving the CRP participants. Results. The results of multi-center testing of methodology for two steps of dosimetry audit show that the design of audit procedures is adequate and the methodology is feasible for meeting the audit objectives. A total of 97% TLD results in heterogeneity situations obtained in the study were within 3% and all results within 5% agreement with the TPS predicted doses. In contrast, only 64% small beam profiles were within 3 mm agreement between the TPS calculated and film measured doses. Film dosimetry results have highlighted some limitations in TPS modeling of small beam profiles in the direction of MLC leave movements. Discussion. Through multi-center testing, any challenges or difficulties in the proposed audit methodology were identified, and the methodology improved. Using the experience of these studies, the participants could incorporate the auditing procedures in their national programs. PMID:26934916

  9. Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: Results of IAEA multi-center studies.

    PubMed

    Izewska, Joanna; Wesolowska, Paulina; Azangwe, Godfrey; Followill, David S; Thwaites, David I; Arib, Mehenna; Stefanic, Amalia; Viegas, Claudio; Suming, Luo; Ekendahl, Daniela; Bulski, Wojciech; Georg, Dietmar

    2016-07-01

    The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP 'Development of Quality Audits for Radiotherapy Dosimetry for Complex Treatment Techniques' was conducted in 2009-2012 as an extension of previously developed audit programs. The CRP work described in this paper focused on developing and testing two steps of dosimetry audit: verification of heterogeneity corrections, and treatment planning system (TPS) modeling of small MLC fields, which are important for the initial stages of complex radiation treatments, such as IMRT. The project involved development of a new solid slab phantom with heterogeneities containing special measurement inserts for thermoluminescent dosimeters (TLD) and radiochromic films. The phantom and the audit methodology has been developed at the IAEA and tested in multi-center studies involving the CRP participants. The results of multi-center testing of methodology for two steps of dosimetry audit show that the design of audit procedures is adequate and the methodology is feasible for meeting the audit objectives. A total of 97% TLD results in heterogeneity situations obtained in the study were within 3% and all results within 5% agreement with the TPS predicted doses. In contrast, only 64% small beam profiles were within 3 mm agreement between the TPS calculated and film measured doses. Film dosimetry results have highlighted some limitations in TPS modeling of small beam profiles in the direction of MLC leave movements. Through multi-center testing, any challenges or difficulties in the proposed audit methodology were identified, and the methodology improved. Using the experience of these studies, the participants could incorporate the auditing procedures in their national programs.

  10. Technical basis for internal dosimetry at Hanford

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1991-07-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ({sup 58}Co, {sup 60}Co, {sup 54}Mn, and {sup 59}Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78more » refs., 35 figs., 115 tabs.« less

  11. Technical basis for internal dosimetry at Hanford

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.

    1989-04-01

    The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products (/sup 58/Co, /sup 60/Co, /sup 54/Mn, and /sup 59/Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation; and bioassay follow-up treatment. 64more » refs., 42 figs., 118 tabs.« less

  12. Fostering a culture of interprofessional education for radiation therapy and medical dosimetry students

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lavender, Charlotte, E-mail: charlavender@gmail.com; Miller, Seth; Church, Jessica

    A less-studied aspect of radiation therapy and medical dosimetry education is experiential learning through attendance at interprofessional conferences. University of North Carolina radiation therapy and medical dosimetry students regularly attended morning conferences and daily pretreatment peer review, including approximately 145 hours of direct interaction with medical attending physicians and residents, medical physicists, and other faculty. We herein assessed the effect of their participation in these interprofessional conferences on knowledge and communication. The students who graduated from our radiation therapy and medical dosimetry programs who were exposed to the interprofessional education initiative were compared with those who graduated in the previousmore » years. The groups were compared with regard to their knowledge (as assessed by grades on end-of-training examinations) and team communication (assessed via survey). The results for the 2 groups were compared via exact tests. There was a trend for the examination scores for the 2012 cohort to be higher than for the 2007 to 2011 groups. Survey results suggested that students who attended the interprofessional education sessions were more comfortable speaking with attending physicians, residents, physicists, and faculty compared with earlier students who did not attend these educational sessions. Interprofessional education, particularly vertical integration, appears to provide an enhanced educational experience both in regard to knowledge (per the examination scores) and in building a sense of communication (via the survey results). Integration of interprofessional education into radiation therapy and medical dosimetry educational programs may represent an opportunity to enrich the learning experience in multiple ways and merits further study.« less

  13. Highway Safety Program Manual: Volume 13: Traffic Engineering Services.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 13 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) focuses on traffic engineering services. The introduction outlines the purposes and objectives of Highway Safety Program Standard 13 and the Highway Safety Program Manual. Program development and…

  14. THERM 5 / WINDOW 5 NFRC simulation manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, Robin; Kohler, Christian; Arasteh, Dariush

    This document, the ''THERM 5/WINDOW 5 NFRC Simulation Manual', discusses how to use the THERM and WINDOW programs to model products for NFRC certified simulations and assumes that the user is already familiar with those programs. In order to learn how to use these programs, it is necessary to become familiar with the material in both the ''THERM User's Manual'' and the ''WINDOW User's Manual''. In general, this manual references the User's Manuals rather than repeating the information. If there is a conflict between either of the User Manual and this ''THERM 5/''WINDOW 5 NFRC Simulation Manual'', the ''THERM 5/WINDOWmore » 5 NFRC Simulation Manual'' takes precedence. In addition, if this manual is in conflict with any NFRC standards, the standards take precedence. For example, if samples in this manual do not follow the current taping and testing NFRC standards, the standards not the samples in this manual, take precedence.« less

  15. 75 FR 52976 - Issuance of Revised Users' Manual for Commission Mediation Program for Investigations Under...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-30

    ... INTERNATIONAL TRADE COMMISSION Issuance of Revised Users' Manual for Commission Mediation Program... 65615 (Nov. 8, 2008). The Commission has determined to issue a revised Users' Manual for its program for the mediation of investigations under section 337 of the Tariff Act of 1930. The revised Users' Manual...

  16. Is eye lens dosimetry needed in nuclear medicine?

    PubMed

    Wrzesień, M; Królicki, L; Albiniak, Ł; Olszewski, J

    2018-06-01

    The exact level of exposure experienced by nuclear medicine personnel, whose work often requires performing manual procedures involving radioactive isotopes, is associated with the form of radiation source used. The variety of radionuclides and medical procedures, and the yearly increase in the number of patients, as well as the change of the individual dose limit for the lens of the eye from a value of 150 mSv yr -1 to 20 mSv yr -1 , mean that issues of eye lens routine dosimetry become interesting from the radiation protection point of view. This paper presents an analysis of the exposure of the eye lenses of nuclear medicine department personnel, as well as those of personnel in the facilities that produce radiopharmaceuticals for the purpose of diagnosis by positron emission tomography, from the viewpoint of the advisability of routine eye lens exposure monitoring, taking into account changes in the dose limit for the lens of the eye. The paper considers the two most commonly used radionuclides for diagnostic purposes 99m Tc, 18 F, and-for therapeutic purposes- 131 I. Dose measurements were made using thermoluminescent detectors. The estimated exposure analysis identifies the cases when the maximum annual value of the personal dose equivalent, in terms of Hp(3), exceeds threefold the new limit value (20 mSv yr -1 ). It is recommended that Hp(3) doses be routinely monitored in the group of radiopharmacists who label pharmaceuticals with the radionuclide 99m Tc and in chemists working in 18 F-FDG quality control departments in production units, where this is carried out manually.

  17. KB3D Reference Manual. Version 1.a

    NASA Technical Reports Server (NTRS)

    Munoz, Cesar; Siminiceanu, Radu; Carreno, Victor A.; Dowek, Gilles

    2005-01-01

    This paper is a reference manual describing the implementation of the KB3D conflict detection and resolution algorithm. The algorithm has been implemented in the Java and C++ programming languages. The reference manual gives a short overview of the detection and resolution functions, the structural implementation of the program, inputs and outputs to the program, and describes how the program is used. Inputs to the program can be rectangular coordinates or geodesic coordinates. The reference manual also gives examples of conflict scenarios and the resolution outputs the program produces.

  18. A complete dosimetry experimental program in support to the core characterization and to the power calibration of the CABRI reactor. A complete dosimetry experimental program in support of the core characterization and of the power calibration of the CABRI reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodiac, F.; Hudelot, JP.; Lecerf, J.

    CABRI is an experimental pulse reactor operated by CEA at the Cadarache research center. Since 1978 the experimental programs have aimed at studying the fuel behavior under Reactivity Initiated Accident (RIA) conditions. Since 2003, it has been refurbished in order to be able to provide RIA and LOCA (Loss Of Coolant Accident) experiments in prototypical PWR conditions (155 bar, 300 deg. C). This project is part of a broader scope including an overall facility refurbishment and a safety review. The global modification is conducted by the CEA project team. It is funded by IRSN, which is conducting the CIP experimentalmore » program, in the framework of the OECD/NEA project CIP. It is financed in the framework of an international collaboration. During the reactor restart, commissioning tests are realized for all equipment, systems and circuits of the reactor. In particular neutronics and power commissioning tests will be performed respectively in 2015 and 2016. This paper focuses on the design of a complete and original dosimetry program that was built in support to the CABRI core characterization and to the power calibration. Each one of the above experimental goals will be fully described, as well as the target uncertainties and the forecasted experimental techniques and data treatment. (authors)« less

  19. 14 CFR 91.1023 - Program operating manual requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... manager must prepare and keep current a program operating manual setting forth procedures and policies acceptable to the Administrator. The program manager's management, flight, ground, and maintenance personnel... personnel. (b) Each program manager must maintain at least one copy of the manual at its principal base of...

  20. Dosimetry for audit and clinical trials: challenges and requirements

    NASA Astrophysics Data System (ADS)

    Kron, T.; Haworth, A.; Williams, I.

    2013-06-01

    Many important dosimetry audit networks for radiotherapy have their roots in clinical trial quality assurance (QA). In both scenarios it is essential to test two issues: does the treatment plan conform with the clinical requirements and is the plan a reasonable representation of what is actually delivered to a patient throughout their course of treatment. Part of a sound quality program would be an external audit of these issues with verification of the equivalence of plan and treatment typically referred to as a dosimetry audit. The increasing complexity of radiotherapy planning and delivery makes audits challenging. While verification of absolute dose delivered at a reference point was the standard of external dosimetry audits two decades ago this is often deemed inadequate for verification of treatment approaches such as Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT). As such, most dosimetry audit networks have successfully introduced more complex tests of dose delivery using anthropomorphic phantoms that can be imaged, planned and treated as a patient would. The new challenge is to adapt this approach to ever more diversified radiotherapy procedures with image guided/adaptive radiotherapy, motion management and brachytherapy being the focus of current research.

  1. ACT Plan: Technical Manual. 2013/2014

    ERIC Educational Resources Information Center

    ACT, Inc., 2013

    2013-01-01

    This manual contains information about the American College Test (ACT) Plan® program. The principal focus of this manual is to document the Plan program's technical adequacy in light of its intended purposes. This manual supersedes the 2011 edition. The content of this manual responds to requirements of the testing industry as established in the…

  2. Items Supporting the Hanford Internal Dosimetry Program Implementation of the IMBA Computer Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, Eugene H.; Bihl, Donald E.

    2008-01-07

    The Hanford Internal Dosimetry Program has adopted the computer code IMBA (Integrated Modules for Bioassay Analysis) as its primary code for bioassay data evaluation and dose assessment using methodologies of ICRP Publications 60, 66, 67, 68, and 78. The adoption of this code was part of the implementation plan for the June 8, 2007 amendments to 10 CFR 835. This information release includes action items unique to IMBA that were required by PNNL quality assurance standards for implementation of safety software. Copie of the IMBA software verification test plan and the outline of the briefing given to new users aremore » also included.« less

  3. International Intercomparison Exercise for Nuclear Accident Dosimetry at the DAF Using GODIVA-IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hickman, David; Hudson, Becka

    The Nuclear Criticality Safety Program operated under the direction of Dr. Jerry McKamy completed the first NNSA Nuclear Accident Dosimetry exercise on May 27, 2016. Participants in the exercise were from Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), Savanah River Site (SRS), Pacific Northwest National Laboratory (PNNL), US Navy, the Atomic Weapons Establishment (United Kingdom) under the auspices of JOWOG 30, and the Institute for Radiological Protection and Nuclear Safety (France) by special invitation and NCSP memorandum of understanding. This exercise was the culmination of a series of Integral Experiment Requests (IER) thatmore » included the establishment of the Nuclear Criticality Experimental Research Center, (NCERC) the startup of the Godiva Reactor (IER-194), the establishment of a the Nuclear Accident Dosimetry Laboratory (NAD LAB) in Mercury, NV, and the determination of reference dosimetry values for the mixed neutron and photon radiation field of Godiva within NCERC.« less

  4. Entrance dose measurements for in‐vivo diode dosimetry: Comparison of correction factors for two types of commercial silicon diode detectors

    PubMed Central

    Zhu, X. R.

    2000-01-01

    Silicon diode dosimeters have been used routinely for in‐vivo dosimetry. Despite their popularity, an appropriate implementation of an in‐vivo dosimetry program using diode detectors remains a challenge for clinical physicists. One common approach is to relate the diode readout to the entrance dose, that is, dose to the reference depth of maximum dose such as dmax for the 10×10 cm2 field. Various correction factors are needed in order to properly infer the entrance dose from the diode readout, depending on field sizes, target‐to‐surface distances (TSD), and accessories (such as wedges and compensate filters). In some clinical practices, however, no correction factor is used. In this case, a diode‐dosimeter‐based in‐vivo dosimetry program may not serve the purpose effectively; that is, to provide an overall check of the dosimetry procedure. In this paper, we provide a formula to relate the diode readout to the entrance dose. Correction factors for TSD, field size, and wedges used in this formula are also clearly defined. Two types of commercial diode detectors, ISORAD (n‐type) and the newly available QED (p‐type) (Sun Nuclear Corporation), are studied. We compared correction factors for TSDs, field sizes, and wedges. Our results are consistent with the theory of radiation damage of silicon diodes. Radiation damage has been shown to be more serious for n‐type than for p‐type detectors. In general, both types of diode dosimeters require correction factors depending on beam energy, TSD, field size, and wedge. The magnitudes of corrections for QED (p‐type) diodes are smaller than ISORAD detectors. PACS number(s): 87.66.–a, 87.52.–g PMID:11674824

  5. Fostering a culture of interprofessional education for radiation therapy and medical dosimetry students.

    PubMed

    Lavender, Charlotte; Miller, Seth; Church, Jessica; Chen, Ronald C; Muresan, Petronella A; Adams, Robert D

    2014-01-01

    A less-studied aspect of radiation therapy and medical dosimetry education is experiential learning through attendance at interprofessional conferences. University of North Carolina radiation therapy and medical dosimetry students regularly attended morning conferences and daily pretreatment peer review, including approximately 145 hours of direct interaction with medical attending physicians and residents, medical physicists, and other faculty. We herein assessed the effect of their participation in these interprofessional conferences on knowledge and communication. The students who graduated from our radiation therapy and medical dosimetry programs who were exposed to the interprofessional education initiative were compared with those who graduated in the previous years. The groups were compared with regard to their knowledge (as assessed by grades on end-of-training examinations) and team communication (assessed via survey). The results for the 2 groups were compared via exact tests. There was a trend for the examination scores for the 2012 cohort to be higher than for the 2007 to 2011 groups. Survey results suggested that students who attended the interprofessional education sessions were more comfortable speaking with attending physicians, residents, physicists, and faculty compared with earlier students who did not attend these educational sessions. Interprofessional education, particularly vertical integration, appears to provide an enhanced educational experience both in regard to knowledge (per the examination scores) and in building a sense of communication (via the survey results). Integration of interprofessional education into radiation therapy and medical dosimetry educational programs may represent an opportunity to enrich the learning experience in multiple ways and merits further study. © 2013 Published by American Association of Medical Dosimetrists on behalf of American Association of Medical Dosimetrists.

  6. Read Aloud Programs for the Elderly Project. Instructional Manual.

    ERIC Educational Resources Information Center

    Leonard, Gloria; And Others

    This manual was developed by the staff of the Read Aloud Programs for the Elderly of the Seattle Public Library. It is based on a year's experience of conducting read-aloud programs in nursing homes and is meant to be a guide for setting up similar programs in other library systems. The first half of the manual, addressed to program managers,…

  7. Addition of higher order plate and shell elements into NASTRAN computer program

    NASA Technical Reports Server (NTRS)

    Narayanaswami, R.; Goglia, G. L.

    1976-01-01

    Two higher order plate elements, the linear strain triangular membrane element and the quintic bending element, along with a shallow shell element, suitable for inclusion into the NASTRAN (NASA Structural Analysis) program are described. Additions to the NASTRAN Theoretical Manual, Users' Manual, Programmers' Manual and the NASTRAN Demonstration Problem Manual, for inclusion of these elements into the NASTRAN program are also presented.

  8. GERTS GQ User's Manual.

    ERIC Educational Resources Information Center

    Akiba, Y.; And Others

    This user's manual for the simulation program Graphical Evaluation and Review Technique (GERT) GQ contains sections on nodes, branches, program input description and format, and program output, as well as examples. Also included is a programmer's manual which contains information on scheduling, subroutine descriptions, COMMON Variables, and…

  9. Airport Performance Model : Volume 2 - User's Manual and Program Documentation

    DOT National Transportation Integrated Search

    1978-10-01

    Volume II contains a User's manual and program documentation for the Airport Performance Model. This computer-based model is written in FORTRAN IV for the DEC-10. The user's manual describes the user inputs to the interactive program and gives sample...

  10. Freeware for reporting radiation dosimetry following the administration of radiopharmaceuticals.

    PubMed

    Gómez Perales, Jesús Luis; García Mendoza, Antonio

    2015-09-01

    This work describes the development of a software application for reporting patient radiation dosimetry following radiopharmaceutical administration. The resulting report may be included within the patient's medical records. The application was developed in the Visual Basic programming language. The dosimetric calculations are based on the values given by the International Commission on Radiological Protection (ICRP). The software is available in both Spanish and English and can be downloaded at no cost from www.radiopharmacy.net. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. History through Art and Architecture: Ancient Greek Architecture [and] Ancient Greek Sculpture. Teacher's Manual.

    ERIC Educational Resources Information Center

    Campbell, Ann

    This document consists of two teaching manuals designed to accompany a commercially-available "multicultural, interdisciplinary video program," consisting of four still videotape programs (72 minutes, 226 frames), one teaching poster, and these two manuals. "Teacher's Manual: Ancient Greek Architecture" covers: "Ancient…

  12. Manual of Accreditation Standards for Adventure Programs 1995.

    ERIC Educational Resources Information Center

    Williamson, John E., Comp.; Gass, Michael, Comp.

    This manual presents standards for adventure education programs seeking accreditation from the Association for Experiential Education. The manual is set up sequentially, focusing both on objective standards such as technical risk management aspects, and on subjective standards such as teaching approaches used in programs. Chapter titles provide…

  13. Book Banquet. A Summer Reading Program Manual.

    ERIC Educational Resources Information Center

    Ward, Caroline; Levine, Joyce

    This manual for the 1993 New York State summer reading program, "Book Banquet," ties books and reading together with the theme of eating. The manual offers program ideas, activities, and materials. The following chapters are included: (1) "Appetizers" (planning, publicity, and promotion); (2) "Setting the Table"…

  14. SU-C-BRD-07: The Radiological Physics Center (RPC): 45 Years of Improving Radiotherapy Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Followill, D; Lowenstein, J; Molineu, A

    Purpose: The RPC, established in 1968 has contributed to the development, conduct, and QA of NCI funded multi-institutional cooperative group clinical trials and institutions, primarily in the USA/Canada and 242 other countries, participating in trials. Methods: The RPC QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program included: 1) remote TLD/OSLD audit of machine output, 2) on-site dosimetry review visits, 3) credentialing for advanced technologies, and 4) review of patientmore » treatment records. The RPC presented and published their findings to the radiation oncology community. Results: The number of institutions monitored by the RPC increased from around 1200 in the late 90s, to ∼2000 in 2013. There were over 4000 megavoltage therapy machines and ∼28,000 therapy beams in the 1991 institutions monitored by the RPC by the end of 2013. Within the 14,000 photon, electron and proton beam outputs remotely monitored with TLD/OSLD annually, between 10-20% of the institutions have one or more beams outside the RPC 5% criterion. Dosimetry site visits to photon and proton centers continue to result in 2-4 recommendations affecting key dosimetry parameters that impact patient treatment times. One in four patient treatment records reviewed by the RPC have their dose data corrected by >5% before trial groups use them for outcomes analysis. Twelve of fourteen clinically active proton centers are approved to participate in NCI funded clinical trials. The RPC published 222 peer reviewed articles since 1972. Conclusion: Findings from the RPC suggest that human errors continue to play a role in radiotherapy discrepancies and without the RPC independent QA program, the number of undetected errors and time elapsed before their discovery would have been greater. Work supported by MGH C06 CA059267 and grants CA10953, CA081647 awarded by NCI, DHHS.« less

  15. Job Hunters' Guidebook Workshop Program. Instructors Manual.

    ERIC Educational Resources Information Center

    Vermont State Dept. of Education, Montpelier.

    Designed with the adult education instructor/supervisor in mind, this manual's purpose is to bring adult education courses into a career focus by providing a group guidance program. Divided into seven sessions, the program outlined in the manual aims to help individuals, with instructor or guidance counselor leadership, to clarify for themselves…

  16. Junior High Computer Studies: Teacher Resource Manual.

    ERIC Educational Resources Information Center

    Alberta Dept. of Education, Edmonton. Curriculum Branch.

    This manual is designed to help classroom teachers in Alberta, Canada implement the Junior High Computer Studies Program. The first eight sections cover the following material: (1) introduction to the teacher resource manual; (2) program rationale and philosophy; (3) general learner expectations; (4) program framework and flexibility; (5) program…

  17. VOC-PLAN: Individual Vocational Education Plan (A Quick, Efficient and Creative Way to Generate Vocational I.E.P.s), Users Manual and Preview Manual.

    ERIC Educational Resources Information Center

    Robinson, Jim; Seabolt, Pete

    This User's Manual is intended to accompany VOC-PLAN, a computer (Apple) program designed to assist in the preparation of an Individualized Vocational Education Program (IVEP) for handicapped, disadvantaged, or regular vocational secondary and postsecondary students. The program is presented in standard IEP (Individualized Education Program)…

  18. Career Education. Industrial Arts Objectives, Grades 6-12. DS Manual 2890.1 [and] Approved List of Essential Textbooks/Instructional Materials for Industrial Arts, Grades 6-12. DS Manual 2890.2; Revised.

    ERIC Educational Resources Information Center

    Dependents Schools (DOD), Washington, DC.

    Designed to assist the instructor in presenting curriculum content based upon industry and technology, this manual presents a program description and the instructional objectives for the industrial arts program in the Department of Defense Dependents Schools (DoDDS). Six sections are included in the manual: Industrial Arts Program Objectives,…

  19. Computer program user's manual for FIREFINDER digital topographic data verification library dubbing system

    NASA Astrophysics Data System (ADS)

    Ceres, M.; Heselton, L. R., III

    1981-11-01

    This manual describes the computer programs for the FIREFINDER Digital Topographic Data Verification-Library-Dubbing System (FFDTDVLDS), and will assist in the maintenance of these programs. The manual contains detailed flow diagrams and associated descriptions for each computer program routine and subroutine. Complete computer program listings are also included. This information should be used when changes are made in the computer programs. The operating system has been designed to minimize operator intervention.

  20. Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcu, Loredana G., E-mail: loredana@marcunet.com; Faculty of Science, University of Oradea; School of Chemistry and Physics, University of Adelaide, South Australia

    2013-10-01

    Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methodsmore » was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.« less

  1. Emerging Approaches and Opportunities to inform Internal Dosimetry and Inter-individual Variability

    EPA Science Inventory

    This talk provided an update to EPA ORD scientists and program officers about planned research within the Chemical Safety for Sustainability program to address chemical toxicokinetics and strategies to understand better the range of variability across different populations and li...

  2. TH-CD-201-08: Flexible Dosimeter Bands for Whole-Body Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, T; Fahimian, B; Pratx, G

    Purpose: The two commonly used radiotherapy techniques are total body irradiation (TBI) and the total skin irradiation (TSI). In order to ensure the accuracy of the prescription beams, the dose received throughout the entire body must be checked using dosimetry. However, the available number of data points is limited as the dosimeters are manually placed on the patient. We developed a flexible and wearable dosimeter that can collect 1D continuous dose information around the peripheral of the patients’ body, including areas obscured from the beam path. Methods: The flexible dosimeter bands are fabricated by embedding storage phosphor powders in amore » thin layer of non-toxic silicone based elastomer (PDMS). An additional elastomer layer is formed on top of the phosphor layer to provide additional mechanical support for the dosimeter. Once the curing process is complete, the dosimeter is cut into multiple bands and rolled into spools prior to use. Results: The dose responses are tested using a preclinical cabinet X-ray system, where the readout is performed with a storage phosphor reader. Results show that the dose calibration factor is ∼1400 (A.U./Gy) from the beam center. Also, 1-D dose distribution experiment was performed in water phantoms, where preliminary results demonstrate that the dose in water is indeed attenuated compared to in air. Conclusion: Dose response and high-resolution 1-D dosimetry is demonstrated using the flexible dosimeters. By providing a detailed spatial description of the beam dose profile, we expect that the dosimeter bands may aid in enhancing the current existing modality in dosimetry. Since the dosimeter is flexible (can retract back to its original length), they can be comfortably worn around the patient. Potentially, multiple 1-D dose information can be stitched together and extrapolated to provide a coarse 3-D image of the dose distribution. This work was supported by funding from the Cutaneous Lymphoma Foundation under the CLARIONS grant.« less

  3. One year follow-up of the Chicago televised smoking cessation program.

    PubMed Central

    Flay, B R; Gruder, C L; Warnecke, R B; Jason, L A; Peterson, P

    1989-01-01

    We compared the relative effectiveness of four different conditions of self-help and social support provided to people attempting to quit smoking in conjunction with a televised cessation program: Smokers ready to quit were able to request written manuals from hardware stores to accompany a televised program. At worksites we provided the written manual to all workers. At a random half of the worksites, we also provided training to discussion leaders who subsequently led discussions among smokers attempting to quit with the program. At health maintenance organization sites we invited smokers who had requested program materials to participate in similar group discussions at health centers. In this paper we report one year follow-up results for the above four groups and compare them with previously reported results of a self-help manual alone. Results for the television plus manual condition were better than those of past studies (25 percent nonsmoking prevalence and 10 percent continuous cessation one year after the program) and considerably better than the manual alone. None of the other conditions designed to supplement the manual plus television produced better long-term outcomes; we explore the reasons for this. The program did encourage and help over 50,000 Chicago smokers to attempt quitting with the American Lung Association manual, 100 times as many as would have done so without the televised program. At least 15 other similar programs implemented since 1984 multiply this effect. PMID:2782506

  4. SRM Manual, Selected Resource Materials: Description and Evaluation.

    ERIC Educational Resources Information Center

    Alberta Dept. of Education, Edmonton. Special Educational Services Branch.

    Provided in the manual is descriptive and evaluative information on 67 instructional materials or programs frequently used with exceptional children in Alberta schools. A flow chart describes the three methods of using the manual: l) to obtain descriptive and evaluative information of an instruction program in the manual 2) to classify and record…

  5. Comparison of manual therapy and exercise therapy in osteoarthritis of the hip: a randomized clinical trial.

    PubMed

    Hoeksma, Hugo L; Dekker, Joost; Ronday, H Karel; Heering, Annet; van der Lubbe, Nico; Vel, Cees; Breedveld, Ferdinand C; van den Ende, Cornelia H M

    2004-10-15

    To determine the effectiveness of a manual therapy program compared with an exercise therapy program in patients with osteoarthritis (OA) of the hip. A single-blind, randomized clinical trial of 109 hip OA patients was carried out in the outpatient clinic for physical therapy of a large hospital. The manual therapy program focused on specific manipulations and mobilization of the hip joint. The exercise therapy program focused on active exercises to improve muscle function and joint motion. The treatment period was 5 weeks (9 sessions). The primary outcome was general perceived improvement after treatment. Secondary outcomes included pain, hip function, walking speed, range of motion, and quality of life. Of 109 patients included in the study, 56 were allocated to manual therapy and 53 to exercise therapy. No major differences were found on baseline characteristics between groups. Success rates (primary outcome) after 5 weeks were 81% in the manual therapy group and 50% in the exercise group (odds ratio 1.92, 95% confidence interval 1.30, 2.60). Furthermore, patients in the manual therapy group had significantly better outcomes on pain, stiffness, hip function, and range of motion. Effects of manual therapy on the improvement of pain, hip function, and range of motion endured after 29 weeks. The effect of the manual therapy program on hip function is superior to the exercise therapy program in patients with OA of the hip.

  6. Manual of an Instructional Program in Dental Assisting.

    ERIC Educational Resources Information Center

    Gilbert, Maud R., Ed.; Fiedler, Belle, Ed.

    This manual is for administrator and teacher use in planning a program and individual courses for adults in dental assisting in vocational, technical, and adult programs. The manual was developed by a supervisor, a teacher-coordinator, teachers, and dentists at the local level and tested in the local school. The objectives are to prepare…

  7. Readers on the Prowl: Florida Library Youth Program Manual.

    ERIC Educational Resources Information Center

    Johnson, Margie, Comp.; Cook, Ann, Comp.; O'Reilly, Lesley, Comp.

    This manual is designed to accompany the 1999 Florida Library Youth Program, focusing on the theme of the library as a destination. This introductory section of the manual contains: an overview of the program that discusses basic philosophy, outreach to children in poverty, age and ability levels, and materials and incentives; a schedule of…

  8. Establishing the LINC (Learning Individualized for Canadians) Program: A Manual for Administrators and Instructors.

    ERIC Educational Resources Information Center

    Tippett, Glen; Mullen, Vernon

    A manual to accompany LINC courses in communications and mathematics, containing information on background, objectives, components, individualized process, and procedures for curriculum development and implementation of LINC Program, is presented. It was formerly referred to as The LINC Program User's Manual. An appendix includes a Reading List…

  9. A Manual for the Anchorage School District Bilingual Education Program Revised Scope and Sequence, K-3.

    ERIC Educational Resources Information Center

    Heinrich, Maria Nieves Bumanlag Lilagan

    The manual offers a systematic set of procedures and relevant information to facilitate effective use of the Anchorage school district (ASD) bilingual education program (BEP). The historical background of the program's development is presented, available manuals for teaching English to limited English proficiency (LEP) students and related…

  10. Manual for a Summer Reading Program.

    ERIC Educational Resources Information Center

    Medina, Sue O.

    This manual provides suggestions for materials and projects to carry out a summer reading program for children based on a monster theme. The planning process outlined may be used as a "how-to" guide for developing summer reading programs on other themes as well. In addition to general guidelines, the manual provides information on the following…

  11. Make Waves: Read! 1998 Summer Library Program Manual. Bulletin No. 98107.

    ERIC Educational Resources Information Center

    Roeber, Jane A., Ed.

    This manual is designed to help individual libraries in Wisconsin plan and implement their summer library programs. The manual is divided into six sections. Section 1 covers planning and promoting programs, and includes reproducible promotional materials, sample letters to parents, and sample media materials. Section 2 provides decorating and…

  12. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers.

    PubMed

    Hourdakis, Constantine J; Boziari, A

    2008-04-01

    Dosimetry quality audits and intercomparisons in radiotherapy centers is a useful tool in order to enhance the confidence for an accurate therapy and to explore and dissolve discrepancies in dose delivery. This is the first national comprehensive study that has been carried out in Greece. During 2002--2006 the Greek Atomic Energy Commission performed a dosimetry quality audit of high energy external photon beams in all (23) Greek radiotherapy centers, where 31 linacs and 13 Co-60 teletherapy units were assessed in terms of their mechanical performance characteristics and relative and absolute dosimetry. The quality audit in dosimetry of external photon beams took place by means of on-site visits, where certain parameters of the photon beams were measured, calculated and assessed according to a specific protocol and the IAEA TRS 398 dosimetry code of practice. In each radiotherapy unit (Linac or Co-60), certain functional parameters were measured and the results were compared to tolerance values and limits. Doses in water under reference and non reference conditions were measured and compared to the stated values. Also, the treatment planning systems (TPS) were evaluated with respect to irradiation time calculations. The results of the mechanical tests, dosimetry measurements and TPS evaluation have been presented in this work and discussed in detail. This study showed that Co-60 units had worse performance mechanical characteristics than linacs. 28% of all irradiation units (23% of linacs and 42% of Co-60 units) exceeded the acceptance limit at least in one mechanical parameter. Dosimetry accuracy was much worse in Co60 units than in linacs. 61% of the Co60 units exhibited deviations outside +/-3% and 31% outside +/-5%. The relevant percentages for the linacs were 24% and 7% respectively. The results were grouped for each hospital and the sources of errors (functional and human) have been investigated and discussed in details. This quality audit proved to be a useful tool for the improvement of quality in radiotherapy. It succeeded to disseminate the IAEA TRS-398 protocol in nearly all radiotherapy centers achieving homogenization and consistency of dosimetry within the country. Also, it detected discrepancies in dosimetry and provided guidance and recommendations to eliminate sources of errors. Finally, it proved that quality assurance programs, periodic quality control tests, maintenance and service play an important role for achieving accuracy and safe operation in radiotherapy.

  13. Automation of film densitometry for application in personal monitoring.

    PubMed

    Taheri, M; Movafeghi, A; Rastkhah, N

    2011-03-01

    In this research work, a semi-automatic densitometry system has been developed for large-scale monitoring services by use of film badge dosemeters. The system consists of a charge-coupled device (CCD)-based scanner that can scan optical densities (ODs) up to 4.2, a computer vision algorithm to improve the quality of digitised films and an analyser program to calculate the necessary information, e.g. the mean OD of region of interest and radiation doses. For calibration of the system, two reference films were used. The Microtek scanner International Color Consortium (ICC) profiler is applied for determining the colour attributes of the scanner accurately and a reference of the density step tablet, Bundesanstalt für Materialforschung und-prüfung (BAM) is used for calibrating the automatic conversion of gray-level values to OD values in the range of 0.2-4.0 OD. The system contributes to achieve more objectives and reliable results. So by applying this system, we can digitise a set of 20 films at once and calculate their relative doses less than about 4 min, and meanwhile it causes to avoid disadvantages of manual process and to enhance the accuracy of dosimetry.

  14. Work Experience Program Teacher Resource Manual. Junior and Senior High School. Interim Edition.

    ERIC Educational Resources Information Center

    Gullekson, Dale

    This manual has been prepared to help educators in Alberta, Canada, organize and operate a work experience program that provides meaningful learning experiences for junior and senior high school students in partnership with the community. The manual: (1) outlines the expectations of the work experience program, including benefits to students,…

  15. Programmed Instruction Manual for a New Solar and Energy Conservation Laboratory. Final Evaluation Report.

    ERIC Educational Resources Information Center

    State Univ. of New York, Farmingdale. Agricultural and Technical Coll.

    A programmed instruction course was developed, consisting of fifteen experiments encompassing eleven separate pieces of equipment operational in a solar and energy conservation lab. The programmed instruction manual for the lab was evaluated and revised during a workshop. This evaluation indicated that both the lab and manual are valuable tools…

  16. Utah Publications Depository Program. Manual of Guidelines for State Agencies, Revised [and] Manual of Guidelines for Depository Libraries, Revised.

    ERIC Educational Resources Information Center

    Utah State Library, Salt Lake City.

    Two manuals provide guidelines for users of the Utah Publications Depository Program. The first, "Guidelines for State Agencies," is designed to assist agencies in complying with the depository law. The program is designed to collect Utah State Governmental publications and to make them available through libraries. State publications…

  17. A resource facility for kinetic analysis: modeling using the SAAM computer programs.

    PubMed

    Foster, D M; Boston, R C; Jacquez, J A; Zech, L

    1989-01-01

    Kinetic analysis and integrated system modeling have contributed significantly to understanding the physiology and pathophysiology of metabolic systems in humans and animals. Many experimental biologists are aware of the usefulness of these techniques and recognize that kinetic modeling requires special expertise. The Resource Facility for Kinetic Analysis (RFKA) provides this expertise through: (1) development and application of modeling technology for biomedical problems, and (2) development of computer-based kinetic modeling methodologies concentrating on the computer program Simulation, Analysis, and Modeling (SAAM) and its conversational version, CONversational SAAM (CONSAM). The RFKA offers consultation to the biomedical community in the use of modeling to analyze kinetic data and trains individuals in using this technology for biomedical research. Early versions of SAAM were widely applied in solving dosimetry problems; many users, however, are not familiar with recent improvements to the software. The purpose of this paper is to acquaint biomedical researchers in the dosimetry field with RFKA, which, together with the joint National Cancer Institute-National Heart, Lung and Blood Institute project, is overseeing SAAM development and applications. In addition, RFKA provides many service activities to the SAAM user community that are relevant to solving dosimetry problems.

  18. Space Trajectories Error Analysis (STEAP) Programs. Volume 1: Analytic manual, update

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Manual revisions are presented for the modified and expanded STEAP series. The STEAP 2 is composed of three independent but related programs: NOMAL for the generation of n-body nominal trajectories performing a number of deterministic guidance events; ERRAN for the linear error analysis and generalized covariance analysis along specific targeted trajectories; and SIMUL for testing the mathematical models used in the navigation and guidance process. The analytic manual provides general problem description, formulation, and solution and the detailed analysis of subroutines. The programmers' manual gives descriptions of the overall structure of the programs as well as the computational flow and analysis of the individual subroutines. The user's manual provides information on the input and output quantities of the programs. These are updates to N69-36472 and N69-36473.

  19. Cuerpo de Paz Manual de Sistema de Programacion y Capacitacion (Peace Corps Programming and Training System Manual): T0063.

    ERIC Educational Resources Information Center

    Peace Corps, Washington, DC.

    This Spanish version of the Peace Corps Programming and Training System Manual is designed to help field staff members of the Peace Corps train volunteers. Its task descriptions, guidelines, examples, and definitions are intended to be practical and informative rather than restrictive. The manual is divided into six major sections: (1)…

  20. The Melwood Manual: A Planning and Operations Manual for Horticultural Training and Work Co-op Programs.

    ERIC Educational Resources Information Center

    Melwood Horticultural Training Center, Inc., Upper Marlboro, MD.

    This manual is intended as a resource for anyone involved in planning, developing, and/or operating a horticultural training or work co-op program for the handicapped. Following an introductory chapter, the manual is divided into three parts with the greatest weight given to the second part. Part I elaborates on development of the horticulture…

  1. Katimavik Participant's Manual, Book III, Work Skills = Katimavik manuel du participant, cahier III, les techniques de travail.

    ERIC Educational Resources Information Center

    Crelinsten, Michael, Ed.

    Part of the documentation for Katimavik, a nine-month volunteer community service and learning program for 17 to 21-year-old Canadians, the bilingual student manual focuses on the work skills portion of the learning program. The manual includes learning program objectives, trimester guidelines and a checklist for activity participation, optional…

  2. Guidelines for Adapting Manualized Interventions for New Target Populations: A Step-Wise Approach Using Anger Management as a Model

    PubMed Central

    Goldstein, Naomi E. S.; Kemp, Kathleen A.; Leff, Stephen S.; Lochman, John E.

    2014-01-01

    The use of manual-based interventions tends to improve client outcomes and promote replicability. With an increasingly strong link between funding and the use of empirically supported prevention and intervention programs, manual development and adaptation have become research priorities. As a result, researchers and scholars have generated guidelines for developing manuals from scratch, but there are no extant guidelines for adapting empirically supported, manualized prevention and intervention programs for use with new populations. Thus, this article proposes step-by-step guidelines for the manual adaptation process. It also describes two adaptations of an extensively researched anger management intervention to exemplify how an empirically supported program was systematically and efficiently adapted to achieve similar outcomes with vastly different populations in unique settings. PMID:25110403

  3. PREFACE: 7th International Conference on 3D Radiation Dosimetry (IC3DDose)

    NASA Astrophysics Data System (ADS)

    Thwaites, David; Baldock, Clive

    2013-06-01

    IC3DDose 2013, the 7th International Conference on 3D Radiation Dosimetry held in Sydney, Australia from 4-8 November 2012, grew out of the DosGel series, which began as DosGel99, the 1st International Workshop on Radiation Therapy Gel Dosimetry in Lexington, Kentucky. Since 1999 subsequent DoSGel conferences were held in Brisbane, Australia (2001), Ghent, Belgium (2004), Sherbrooke, Canada (2006) and Crete, Greece (2008). In 2010 the conference was held on Hilton Head Island, South Carolina and underwent a name-change to IC3DDose. The aim of the first workshop was to bring together individuals, both researchers and users, with an interest in 3D radiation dosimetry techniques, with a mix of presentations from basic science to clinical applications, which has remained an objective for all of the meetings. One rationale of DosGel99 was stated as supporting the increasing clinical implementation of gel dosimetry, as the technique appeared, at that time, to be leaving the laboratories of gel dosimetry enthusiasts and entering clinical practice. Clearly by labelling the first workshop as the 1st, there was a vision of a continuing series, which has been fulfilled. On the other hand, the expectation of widespread clinical use of gel dosimetry has perhaps not been what was hoped for and anticipated. Nevertheless the rapidly increasing demand for advanced high-precision 3D radiotherapy technology and techniques has continued apace. The need for practical and accurate 3D dosimetry methods for development and quality assurance has only increased. By the 6th meeting, held in South Carolina in 2010, the Conference Scientific Committee recognised the wider developments in 3D systems and methods and decided to widen the scope, whilst keeping the same span from basic science to applications. This was signalled by a change of name from 'Dosgel' to 'IC3DDose', a name that has continued to this latest conference. The conference objectives were: to enhance the quality and accuracy of radiation therapy treatment through improved clinical dosimetry to investigate and understand the dosimetric challenges of modern radiation treatments to provide a forum to discuss the latest research and developments in 3D and advanced radiation dosimetry to energise and diversify dosimetry research and clinical practice by encouraging interaction and synergy between advanced, 3D and semi-3D dosimetry techniques We believe the conference program, with its excellent range of expert and specialist speakers, met these objectives. Thanks are due to all invited speakers for their participation, to the Local Organising Committee members for all their hard work in making the conference happen, particularly the small core administrative support group, and to the range of academic, organisation and commercial sponsors who generously supported the meeting. The Scientific Committee members are also thanked for reviewing the submitted manuscripts and for assisting in the editorial process. Finally, all who travelled to Sydney, Australia for the meeting are acknowledged for choosing to attend and contribute to making this a successful conference. Local Conference Organising Committee David Thwaites (Conference Convener) Clive Baldock Leanne Price Elizabeth Starkey May Whitaker Peter Greer Lois Holloway Phil Vial Robin Hill Conference Scientific Committee Sven Back (Sweden) Clive Baldock (Australia) Cheng-Shie Wuu (USA) Yves de Deene (Belgium) Simon Doran (UK) Geoffrey Ibbott (USA) Andrew Jirasek (Canada) Kevin Jordan (Canada) Martin Lepage (Canada) Mark Oldham (USA) Evangelos Pappas (Greece) John Schreiner (Canada) David Thwaites (Australia) David ThwaitesClive Baldock DirectorExecutive Dean Institute of Medical PhysicsFaculty of Science School of PhysicsMacquarie University University of SydneyNorth Ryde NSW 2006NSW 2109 AustraliaAustralia The PDF also contains the conference program.

  4. FLAPS (Fatigue Life Analysis Programs): Computer Programs to Predict Cyclic Life Using the Total Strain Version of Strainrange Partitioning and Other Life Prediction Methods. Users' Manual and Example Problems, Version 1.0

    NASA Technical Reports Server (NTRS)

    Arya, Vinod K.; Halford, Gary R. (Technical Monitor)

    2003-01-01

    This manual presents computer programs FLAPS for characterizing and predicting fatigue and creep-fatigue resistance of metallic materials in the high-temperature, long-life regime for isothermal and nonisothermal fatigue. The programs use the Total Strain version of Strainrange Partitioning (TS-SRP), and several other life prediction methods described in this manual. The user should be thoroughly familiar with the TS-SRP and these life prediction methods before attempting to use any of these programs. Improper understanding can lead to incorrect use of the method and erroneous life predictions. An extensive database has also been developed in a parallel effort. The database is probably the largest source of high-temperature, creep-fatigue test data available in the public domain and can be used with other life-prediction methods as well. This users' manual, software, and database are all in the public domain and can be obtained by contacting the author. The Compact Disk (CD) accompanying this manual contains an executable file for the FLAPS program, two datasets required for the example problems in the manual, and the creep-fatigue data in a format compatible with these programs.

  5. Michigan Department of Transportation state planning and research part II program : research and implementation manual [revised June 2014].

    DOT National Transportation Integrated Search

    2014-06-01

    The Research and Implementation Manual describes the administrative processes used by : Research Administration to develop and implement the Michigan Department of Transportation : (MDOT) research program. Contents of this manual include a discussion...

  6. SU-F-T-262: Commissioning Varian Portal Dosimetry for EPID-Based Patient Specific QA in a Non-Aria Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, M; Knutson, N; University of Rhode Island, Kingston, RI

    2016-06-15

    Purpose: Development of an in-house program facilitates a workflow that allows Electronic Portal Imaging Device (EPID) patient specific quality assurance (QA) measurements to be acquired and analyzed in the Portal Dosimetry Application (Varian Medical Systems, Palo Alto, CA) using a non-Aria Record and Verify (R&V) system (MOSAIQ, Elekta, Crawley, UK) to deliver beams in standard clinical treatment mode. Methods: Initial calibration of an in-house software tool includes characterization of EPID dosimetry parameters by importing DICOM images of varying delivered MUs to determine linear mapping factors in order to convert image pixel values to Varian-defined Calibrated Units (CU). Using this information,more » the Portal Dose Image Prediction (PDIP) algorithm was commissioned by converting images of various field sizes to output factors using the Eclipse Scripting Application Programming Interface (ESAPI) and converting a delivered configuration fluence to absolute dose units. To verify the algorithm configuration, an integrated image was acquired, exported directly from the R&V client, automatically converted to a compatible, calibrated dosimetric image, and compared to a PDIP calculated image using Varian’s Portal Dosimetry Application. Results: For two C-Series and one TrueBeam Varian linear accelerators, gamma comparisons (global 3% / 3mm) of PDIP algorithm predicted dosimetric images and images converted via the inhouse system demonstrated agreement for ≥99% of all pixels, exceeding vendor-recommended commissioning guidelines. Conclusion: Combinations of a programmatic image conversion tool and ESAPI allow for an efficient and accurate method of patient IMRT QA incorporating a 3rd party R&V system.« less

  7. Instruct coders' manual

    NASA Technical Reports Server (NTRS)

    Friend, J.

    1971-01-01

    A manual designed both as an instructional manual for beginning coders and as a reference manual for the coding language INSTRUCT, is presented. The manual includes the major programs necessary to implement the teaching system and lists the limitation of current implementation. A detailed description is given of how to code a lesson, what buttons to push, and what utility programs to use. Suggestions for debugging coded lessons and the error messages that may be received during assembly or while running the lesson are given.

  8. Simple Experiments in Psychology.

    ERIC Educational Resources Information Center

    Ray, Wilbert S.

    This material, developed for use in secondary schools, is a programmed-type learning package consisting of an "Instructor's Manual", a "Student's Introduction", and a "Laboratory Manual". The general goal of the program is to teach students to distinguish between reliable and unreliable information. The "Laboratory Manual" contains nine simple…

  9. Michigan Department of Transportation state planning and research part II program : research and implementation manual [revision 3: October 2015].

    DOT National Transportation Integrated Search

    2015-01-01

    The Research and Implementation Manual describes the administrative processes used by Research Administration to develop and implement the Michigan Department of Transportation (MDOT) research program. Contents of this manual include a discussion of ...

  10. Testing an automated method to estimate ground-water recharge from streamflow records

    USGS Publications Warehouse

    Rutledge, A.T.; Daniel, C.C.

    1994-01-01

    The computer program, RORA, allows automated analysis of streamflow hydrographs to estimate ground-water recharge. Output from the program, which is based on the recession-curve-displacement method (often referred to as the Rorabaugh method, for whom the program is named), was compared to estimates of recharge obtained from a manual analysis of 156 years of streamflow record from 15 streamflow-gaging stations in the eastern United States. Statistical tests showed that there was no significant difference between paired estimates of annual recharge by the two methods. Tests of results produced by the four workers who performed the manual method showed that results can differ significantly between workers. Twenty-two percent of the variation between manual and automated estimates could be attributed to having different workers perform the manual method. The program RORA will produce estimates of recharge equivalent to estimates produced manually, greatly increase the speed od analysis, and reduce the subjectivity inherent in manual analysis.

  11. Monte Carlo simulations to replace film dosimetry in IMRT verification.

    PubMed

    Goetzfried, Thomas; Rickhey, Mark; Treutwein, Marius; Koelbl, Oliver; Bogner, Ludwig

    2011-01-01

    Patient-specific verification of intensity-modulated radiation therapy (IMRT) plans can be done by dosimetric measurements or by independent dose or monitor unit calculations. The aim of this study was the clinical evaluation of IMRT verification based on a fast Monte Carlo (MC) program with regard to possible benefits compared to commonly used film dosimetry. 25 head-and-neck IMRT plans were recalculated by a pencil beam based treatment planning system (TPS) using an appropriate quality assurance (QA) phantom. All plans were verified both by film and diode dosimetry and compared to MC simulations. The irradiated films, the results of diode measurements and the computed dose distributions were evaluated, and the data were compared on the basis of gamma maps and dose-difference histograms. Average deviations in the high-dose region between diode measurements and point dose calculations performed with the TPS and MC program were 0.7 ± 2.7% and 1.2 ± 3.1%, respectively. For film measurements, the mean gamma values with 3% dose difference and 3mm distance-to-agreement were 0.74 ± 0.28 (TPS as reference) with dose deviations up to 10%. Corresponding values were significantly reduced to 0.34 ± 0.09 for MC dose calculation. The total time needed for both verification procedures is comparable, however, by far less labor intensive in the case of MC simulations. The presented study showed that independent dose calculation verification of IMRT plans with a fast MC program has the potential to eclipse film dosimetry more and more in the near future. Thus, the linac-specific QA part will necessarily become more important. In combination with MC simulations and due to the simple set-up, point-dose measurements for dosimetric plausibility checks are recommended at least in the IMRT introduction phase. Copyright © 2010. Published by Elsevier GmbH.

  12. National Household Education Surveys Program of 2012: Data File User's Manual. Parent and Family Involvement in Education Survey. Early Childhood Program Participation Survey. NCES 2015-030

    ERIC Educational Resources Information Center

    McPhee, C.; Bielick, S.; Masterton, M.; Flores, L.; Parmer, R.; Amchin, S.; Stern, S.; McGowan, H.

    2015-01-01

    The 2012 National Household Education Surveys Program (NHES:2012) Data File User's Manual provides documentation and guidance for users of the NHES:2012 data files. The manual provides information about the purpose of the study, the sample design, data collection procedures, data processing procedures, response rates, imputation, weighting and…

  13. User's manual for three-dimensional analysis of propeller flow fields

    NASA Technical Reports Server (NTRS)

    Chaussee, D. S.; Kutler, P.

    1983-01-01

    A detailed operating manual is presented for the prop-fan computer code (in addition to supporting programs) recently developed by Kutler, Chaussee, Sorenson, and Pulliam while at the NASA'S Ames Research Center. This code solves the inviscid Euler equations using an implicit numerical procedure developed by Beam and Warming of Ames. A description of the underlying theory, numerical techniques, and boundary conditions with equations, formulas, and methods for the mesh generation program (MGP), three dimensional prop-fan flow field program (3DPFP), and data reduction program (DRP) is provided, together with complete operating instructions. In addition, a programmer's manual is also provided to assist the user interested in modifying the codes. Included in the programmer's manual for each program is a description of the input and output variables, flow charts, program listings, sample input and output data, and operating hints.

  14. Manual for a Volunteer Services System.

    ERIC Educational Resources Information Center

    Helgerson, Linda; And Others

    This manual presents guidelines for planning, monitoring, and controlling the development and operation of volunteer assistance programs. The materials included address questions related to both the process of establishing a volunteer program and the administration of a volunteer management system. The manual is not intended to provide a blueprint…

  15. Users' Manual for ILSS (Revised ILSLOC) : Simulation for Derogation Effects on the Instrument Landing System

    DOT National Transportation Integrated Search

    1976-12-01

    The manual presents the complete ILSLOC computer program package. In addition to including a thorough description of the program itself and a commented listing, the manual contains a brief description of the ILS system and antenna patterns. To illust...

  16. Library Service to the Spanish Speaking.

    ERIC Educational Resources Information Center

    Peterson, Anita R.

    This manual was developed to formalize Inglewood Public Library's existing policies and programs regarding library services to the Spanish speaking, and to define future program goals. The introduction discusses why such services have been initiated, why the manual was developed, and the potential benefits the manual has for library…

  17. School District Energy Manual.

    ERIC Educational Resources Information Center

    Association of School Business Officials International, Reston, VA.

    This manual serves as an energy conservation reference and management guide for school districts. The School District Energy Program (SDEP) is designed to provide information and/or assistance to school administrators planning to implement a comprehensive energy management program. The manual consists of 15 parts. Part 1 describes the SDEP; Parts…

  18. Resource Manual for Health Occupations Education Instructors.

    ERIC Educational Resources Information Center

    Feilner, Veronica, Ed.; Robling, Jeannine, Ed.

    This resource manual is designed to assist secondary health occupations instructors in implementing their health occupations programs. It contains two types of materials: informational topics and sample forms, letters, memos, and other materials. The manual begins with an overview of the health occupations education program, followed by these…

  19. Developing Childhood Injury Prevention Programs: An Administrative Guide for State Maternal and Child Health (Title V) Programs.

    ERIC Educational Resources Information Center

    Birch & Davis Associates, Inc., Silver Spring, MD.

    Based primarily on the experience of three childhood injury prevention demonstration projects, this manual provides state Title V program directors with an action guide for developing targeted childhood injury prevention programs. The manual is divided into four sections: background; program planning; program design; and program implementation and…

  20. Flight dynamics analysis and simulation of heavy lift airships. Volume 3: User's manual

    NASA Technical Reports Server (NTRS)

    Emmen, R. D.; Tischler, M. B.

    1982-01-01

    The User's Manual provides the basic information necessary to run the programs. This includes descriptions of the various data files necessary for the program, the various outputs from the program and the options available to the user when executing the program. Additional data file information is contained in the three appendices to the manual. These appendices list all input variables and their permissible values, an example listing of these variables, and all output variables available to the user.

  1. Mask Analysis Program (MAP) reference manual

    NASA Technical Reports Server (NTRS)

    Mitchell, C. L.

    1976-01-01

    A document intended to serve as a User's Manual and a Programmer's Manual for the Mask Analysis Program is presented. The first portion of the document is devoted to the user. It contains all of the information required to execute MAP. The remainder of the document describes the details of MAP software logic. Although the information in this portion is not required to run the program, it is recommended that every user review it to gain an appreciation for the program functions.

  2. Planning and Implementation Issues in Bilingual Education Programming. Manual V.

    ERIC Educational Resources Information Center

    Santos-Rivera, Iris; And Others

    Bilingual program development is thoroughly surveyed in this manual. Community involvement in program development is discussed, and suggestions for collecting socio-cultural data appropriate to community role are set forth. Various options for choosing a program at the elementary and secondary levels are presented. Program content is treated in…

  3. Advances in Exposure Science (Washington, DC Modernized TSCA meeting)

    EPA Science Inventory

    I am describing current research from the Chemical Safety for Sustainability research program's Rapid Exposure and Dosimetry project that relates to predicting human exposure to environmental chemicals for thousands of chemicals.

  4. 1999 commuter assistance program evaluation manual

    DOT National Transportation Integrated Search

    2001-01-01

    This manual was developed to assist Florida's Commuter Assistance Programs (CAP) to measure and evaluate their performance. It provides information necessary for a CAP to create and implement its own evaluation program. It discusses performance measu...

  5. School Fire Safety Manual.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock. General Education Div.

    This manual provides the background information necessary for the planning of school fire safety programs by local school officials, particularly in Arkansas. The manual first discusses the need for such programs and cites the Arkansas state law regarding them. Policies established by the Arkansas State Board of Education to implement the legal…

  6. Math and Science Model Programs Manual.

    ERIC Educational Resources Information Center

    Sawyer, Donna, Comp.; And Others

    This implementation manual has been developed to describe four model mathematics and science programs designed to increase African-American students' interest in mathematics and science. The manual will help affiliates of the Urban League to mobilize existing community resources to achieve the goals of the national education initiative. The four…

  7. User's manual for ILSLOC : simulation for derogation effects on the localizer portion of the Instrument Landing System

    DOT National Transportation Integrated Search

    1973-08-01

    The manual presents the complete ILSLOC computer program package. In addition to including a thorough description of the program itself and a commented listing, the manual contains a brief description of the ILS system and antenna patterns. To illust...

  8. Improving Sex Equity in Postsecondary Vocational/Technical Programs: A Resource Manual.

    ERIC Educational Resources Information Center

    Lovelace, Bill E.; And Others

    This manual was developed to assist postsecondary administrators, faculty, staff, and students by providing materials specifically designed to eliminate sex bias and stereotyping of students and to recruit students into nontraditional careers and vocational-technical programs. The manual is organized in six sections. The first section introduces…

  9. Dental Aide. Student Manual [and] Instructor Key. Revised.

    ERIC Educational Resources Information Center

    Heckman, Karen; Noirfalise, Pat

    The first component of this three-part package is a student manual designed to be used independently in secondary health occupations programs or on-the-job training programs for dental assistants. The manual contains seven units that cover the following topics: introduction to dentistry; basic office procedures; infection control and occupational…

  10. Community-Based Prevention Specialist. Trainer Manual.

    ERIC Educational Resources Information Center

    University Research Corp., Bethesda, MD.

    This trainer manual is designed to assist facilitators in the design of entry-level courses and programs for substance abuse prevention specialists. The manual initially concentrates on a basic, generic approach to community work, and introduces the knowledge and skills needed to implement substance abuse prevention programs by using the community…

  11. A Teacher's Spelling Manual for Seventh Grade.

    ERIC Educational Resources Information Center

    Datres, Kristine, Comp.; Heggenstaller, Barbara, Comp.

    The spelling program described in this manual was designed with the idea that spelling study initiated in the elementary grades should continue through the middle school years. The manual first describes the program's objectives: to help students learn basic spelling rules, develop an interest in word lore and vocabulary improvement, and develop…

  12. Healthy Young Children: A Manual for Programs.

    ERIC Educational Resources Information Center

    Kendrick, Abby Shapiro, Ed.; And Others

    This manual, which was developed as a reference and resource guide for program directors and teachers of young children, describes high standards for health policies. Also provided are information based on current research and recommendations from experts in health and early childhood education. The manual contains 7 sections and 19 chapters.…

  13. Lights, Camera, Read! Arizona Reading Program Manual.

    ERIC Educational Resources Information Center

    Arizona State Dept. of Library, Archives and Public Records, Phoenix.

    This document is the manual for the Arizona Reading Program (ARP) 2003 entitled "Lights, Camera, Read!" This theme spotlights books that were made into movies, and allows readers to appreciate favorite novels and stories that have progressed to the movie screen. The manual consists of eight sections. The Introduction includes welcome…

  14. English in the Work Place for School Custodians. Manual and Curriculum Guide.

    ERIC Educational Resources Information Center

    Cruz, Jane; And Others

    This manual is intended to assist in the development of programs in vocational English as a Second Language (VESL) for limited-English-speaking individuals working as school custodians. The manual describes steps in program development, offers methods for needs assessment, specifies instructional objectives, discusses techniques for lesson…

  15. Computer Program User’s Manual for FIREFINDER Digital Topographic Data Verification Library Dubbing System,

    DTIC Science & Technology

    1981-11-30

    COMPUTER PROGRAM USER’S MANUAL FOR FIREFINDER DIGITAL TOPOGRAPHIC DATA VERIFICATION LIBRARY DUBBING SYSTEM 30 NOVEMBER 1981 by: Marie Ceres Leslie R...Library .............................. 1-2 1.2.3 Dubbing .......................... 1-2 1.3 Library Process Overview ..................... 1-3 2 LIBRARY...RPOSE AND SCOPE This manual describes the computer programs for the FIREFINDER Digital Topographic Data Veri fication-Library- Dubbing System (FFDTDVLDS

  16. Navy Occupational Health Information Management System (NOHIMS). Medical Exam Scheduling Module. Program Maintenance Manual

    DTIC Science & Technology

    1987-06-01

    NAVY OCCUPATIONAL HEALTH INFORMATION MANAGEMENT SYSTEM NOH I MS MEDICAL EXAM SCHEDULING MODULE PROGRAM MAINTENANCE MANUAL S JUNE 1987 DT11C 00... Information Management System (NOHIMS) ~ Medical Examination Scheduling (MES) Program Maintenance Manual 7. Author(s) 8. Performing Organization Rapt. No...the Navy Occupational Health Information Management System (NOHIMS). NOHIMS, whose initial version was developed at the Naval Health Research Center

  17. WIPP waste characterization program sampling and analysis guidance manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-01-01

    The Waste Isolation Pilot Plant (WIPP) Waste Characterization Program Sampling and Analysis Guidance Manual (Guidance Manual) provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Quality Assurance Program Plan (QAPP) for the WIPP Experimental-Waste Characterization Program (the Program). This Guidance Manual includes all of the sampling and testing methodologies accepted by the WIPP Project Office (DOE/WPO) for use in implementing the Program requirements specified in the QAPP. This includes methods for characterizing representative samples of transuranic (TRU) wastesmore » at DOE generator sites with respect to the gas generation controlling variables defined in the WIPP bin-scale and alcove test plans, as well as waste container headspace gas sampling and analytical procedures to support waste characterization requirements under the WIPP test program and the Resource Conservation and Recovery Act (RCRA). The procedures in this Guidance Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site specific procedures. The use of these procedures is intended to provide the necessary sensitivity, specificity, precision, and comparability of analyses and test results. The solutions to achieving specific program objectives will depend upon facility constraints, compliance with DOE Orders and DOE facilities' operating contractor requirements, and the knowledge and experience of the TRU waste handlers and analysts. With some analytical methods, such as gas chromatography/mass spectrometry, the Guidance Manual procedures may be used directly. With other methods, such as nondestructive/destructive characterization, the Guidance Manual provides guidance rather than a step-by-step procedure.« less

  18. Technology Reinvestment Project Manufacturing Education and Training. Volume 1

    NASA Technical Reports Server (NTRS)

    Schroer, Bernard J.; Bond, Arthur J.

    1997-01-01

    The manufacturing education program is a joint program between the University of Alabama in Huntsville's (UAH) College of Engineering and Alabama A&M University's (AAMLJ) School of Engineering and Technology. The objective of the program is to provide more hands-on experiences to undergraduate engineering and engineering technology students. The scope of work consisted of. Year 1, Task 1: Review courses at Alabama Industrial Development Training (AIDT); Task 2: Review courses at UAH and AAMU; Task 3: Develop new lab manuals; Task 4: Field test manuals; Task 5: Prepare annual report. Year 2, Task 1: Incorporate feedback into lab manuals; Task 2 : Introduce lab manuals into classes; Task 3: Field test manuals; Task 4: Prepare annual report. Year 3, Task 1: Incorporate feedback into lab manuals; Task 2: Introduce lab manuals into remaining classes; Task 3: Conduct evaluation with assistance of industry; Task 4: Prepare final report. This report only summarizes the activities of the University of Alabama in Huntsville. The activities of Alabama A&M University are contained in a separate report.

  19. Outdoor Education Manual.

    ERIC Educational Resources Information Center

    Gooyers, Cobina; And Others

    Designed for teachers to provide students with an awareness of the world of nature which surrounds them, the manual presents the philosophy of outdoor education, goals and objectives of the school program, planning for outdoor education, the Wildwood Programs, sequential program planning for students, program booking and resource list. Content…

  20. Program manual for the Shuttle Electric Power System analysis computer program (SEPS), volume 1 of program documentation

    NASA Technical Reports Server (NTRS)

    Bains, R. W.; Herwig, H. A.; Luedeman, J. K.; Torina, E. M.

    1974-01-01

    The Shuttle Electric Power System (SEPS) computer program is considered in terms of the program manual, programmer guide, and program utilization. The main objective is to provide the information necessary to interpret and use the routines comprising the SEPS program. Subroutine descriptions including the name, purpose, method, variable definitions, and logic flow are presented.

  1. An analysis for high speed propeller-nacelle aerodynamic performance prediction. Volume 2: User's manual

    NASA Technical Reports Server (NTRS)

    Egolf, T. Alan; Anderson, Olof L.; Edwards, David E.; Landgrebe, Anton J.

    1988-01-01

    A user's manual for the computer program developed for the prediction of propeller-nacelle aerodynamic performance reported in, An Analysis for High Speed Propeller-Nacelle Aerodynamic Performance Prediction: Volume 1 -- Theory and Application, is presented. The manual describes the computer program mode of operation requirements, input structure, input data requirements and the program output. In addition, it provides the user with documentation of the internal program structure and the software used in the computer program as it relates to the theory presented in Volume 1. Sample input data setups are provided along with selected printout of the program output for one of the sample setups.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thrall, Brian D.; Minard, Kevin R.; Teeguarden, Justin G.

    A Cooperative Research and Development Agreement (CRADA) was sponsored by Battelle Memorial Institute (Battelle, Columbus), to initiate a collaborative research program across multiple Department of Energy (DOE) National Laboratories aimed at developing a suite of new capabilities for predictive toxicology. Predicting the potential toxicity of emerging classes of engineered nanomaterials was chosen as one of two focusing problems for this program. PNNL’s focus toward this broader goal was to refine and apply experimental and computational tools needed to provide quantitative understanding of nanoparticle dosimetry for in vitro cell culture systems, which is necessary for comparative risk estimates for different nanomaterialsmore » or biological systems. Research conducted using lung epithelial and macrophage cell models successfully adapted magnetic particle detection and fluorescent microscopy technologies to quantify uptake of various forms of engineered nanoparticles, and provided experimental constraints and test datasets for benchmark comparison against results obtained using an in vitro computational dosimetry model, termed the ISSD model. The experimental and computational approaches developed were used to demonstrate how cell dosimetry is applied to aid in interpretation of genomic studies of nanoparticle-mediated biological responses in model cell culture systems. The combined experimental and theoretical approach provides a highly quantitative framework for evaluating relationships between biocompatibility of nanoparticles and their physical form in a controlled manner.« less

  3. Programmer's manual for the Mission Analysis Evaluation and Space Trajectory Operations program (MAESTRO)

    NASA Technical Reports Server (NTRS)

    Lutzky, D.; Bjorkman, W. S.

    1973-01-01

    The Mission Analysis Evaluation and Space Trajectory Operations program known as MAESTRO is described. MAESTRO is an all FORTRAN, block style, computer program designed to perform various mission control tasks. This manual is a guide to MAESTRO, providing individuals the capability of modifying the program to suit their needs. Descriptions are presented of each of the subroutines descriptions consist of input/output description, theory, subroutine description, and a flow chart where applicable. The programmer's manual also contains a detailed description of the common blocks, a subroutine cross reference map, and a general description of the program structure.

  4. SRB-3D Solid Rocket Booster performance prediction program. Volume 3: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Winkler, J. C.

    1976-01-01

    The programmer's manual for the Modified Solid Rocket Booster Performance Prediction Program (SRB-3D) describes the major control routines of SRB-3D, followed by a super index listing of the program and a cross-reference of the program variables.

  5. Principles of Training in Marine Corps Task Analysis. Training Manual I. Evaluation of the Marine Corps Task Analysis Program. Technical Report No. 7.

    ERIC Educational Resources Information Center

    Kuriloff, Arthur H.

    This is the first in a series of five training manuals developed for use by the U.S. Marine Corps Office of Manpower Utilization (OMU) in its Task Analysis (TA) program. It is designed for trainers of OMU staff members assigned to the TA program, a research effort requiring interpersonal and research competence. Objectives of the manual are: (1)…

  6. Navy Occupational Health Information Management System (NOHIMS). System-Wide Module. Program Maintenance Manual

    DTIC Science & Technology

    1987-06-01

    NAVY OCCUPATIONAL HEALTH INFORMATION MANAGEMENT SYSTEM NOHIMS SYSTEM-WIDE MODULE PROGRAM MAINTENANCE MANUAL JUNE 1987 DTIC 00 SEP I 21988DJ 0) 4... INFORMATION MANAGEMENT SYSTEM (NOHIMS) N 1.98 SYSTEM-WIDE MODULE PROGRAM MAINTENANCE MANUAL 7. Author(s) a. Performing Organization Rapt. No. MITRE... Management System (NOHIMS). NORIMS, whose initial version was ,eveloped at the Naval Health Research Center (NHRC), is a composite of 4 -’o subsystems: an

  7. Hanford Laboratories monthly activities report, March 1964

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1964-04-15

    The monthly report for the Hanford Laboratories Operation, March 1964. Reactor fuels, chemistry, dosimetry, separation processes, reactor technology, financial activities, biology operation, and physics and instrumentation research, and applied mathematics operation, and programming operations are discussed.

  8. Super Summer Safari Manual: 1989 Summer Library Program. Bulletin No. 9240.

    ERIC Educational Resources Information Center

    Roeber, Jane A., Ed.

    Based on the theme, "Super Summer Safari: Make Books Your Big Game," this manual describes library activities intended to stimulate family explorations of local and regional natural environments, of urban parks, and of agricultural settings. The manual is divided into 6 sections: (1) "Planning and Promoting Programs"; (2)…

  9. Maximum speed limits. Volume 3, A programmed implementation manual for setting a speed limit based on the 85th percentile

    DOT National Transportation Integrated Search

    1970-10-01

    This report contains the implementation manual developed as a part of the project "Maximum Speed Limits." The manual consists of a programed educational unit and a field workguide concerning the setting of speed limits based on the 85th percentile sp...

  10. Understanding the Defiant Child. [Videotape and Program Manual].

    ERIC Educational Resources Information Center

    Barkley, Russell A.

    This videotape recording and accompanying program manual are intended to provide a review of current knowledge about defiance in children, a behavior pattern that research suggests may be increasing in prevalence and that is a known precursor to serious disorders such as oppositional defiant disorder (ODD) and conduct disorder. The manual provides…

  11. Your Library--Greatest Show of All! Activity Manual.

    ERIC Educational Resources Information Center

    Jackson, Mary, Ed.

    Intended as a companion volume for librarians planning a children's summer reading program, this activity manual provides ideas for games, puzzles, puppet shows, story reading, and more, all based on the theme of "Circus Summer." The manual suggests ways to promote the program, such as visits to schools, and provides directions for…

  12. 78 FR 22536 - Procedural Manual for the Election Assistance Commission's Voting System Test Laboratories...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ... System Test Laboratories Program Manual, Version 2.0 AGENCY: United States Election Assistance Commission (EAC). ACTION: Notice; publication of Voting System Test Laboratories Program Manual, Version 2.0, for 60 day public comment period on EAC Web site. SUMMARY: The U.S. Election Assistance Commission (EAC...

  13. Handbook for Classroom Testing in Peace Corps Language Programs. Manual T0068.

    ERIC Educational Resources Information Center

    Anderson, Neil J.

    This manual provides instructors in Peace Corps language training programs with information about two kinds of classroom testing: formative, ongoing testing and summative testing that occurs at the end of an instructional period. The first of the manual's four chapters on the purposes of language testing, discusses language testing within a…

  14. The Bleeder's Digest: A Campus Blood Collection Reference Manual.

    ERIC Educational Resources Information Center

    Bean, Melissa; And Others

    This manual was written for students and blood donor recruiters interested in starting a campus blood program or in improving an already existing blood program. Contents include discussions of the reasons for blood programs, goals, elements of successful programs, organization of student committees, and comprehensive planning for annual campus and…

  15. Solid rocket booster thermal radiation model. Volume 2: User's manual

    NASA Technical Reports Server (NTRS)

    Lee, A. L.

    1976-01-01

    A user's manual was prepared for the computer program of a solid rocket booster (SRB) thermal radiation model. The following information was included: (1) structure of the program, (2) input information required, (3) examples of input cards and output printout, (4) program characteristics, and (5) program listing.

  16. Day Camp Manual: Program. Book IV.

    ERIC Educational Resources Information Center

    Babcock, William

    Book IV in a 5-book day camp manual discusses the camp program. Section I describes the organization, definition, and elements essential to successful day camp programs. Section II, which addresses the benefits and special considerations of mass programs, includes rainy day contingencies, materials to have on hand, and activity suggestions.…

  17. Program user's manual for an unsteady helicopter rotor-fuselage aerodynamic analysis

    NASA Technical Reports Server (NTRS)

    Lorber, Peter F.

    1988-01-01

    The Rotor-Fuselage Analysis is a method of calculating the aerodynamic reaction between a helicopter rotor and fuselage. This manual describes the structure and operation of the computer programs that make up the Rotor-Fuselage Analysis, programs which prepare the input and programs which display the output.

  18. A mineral reconnaissance sampling manual for Costa Rica: Central American energy and resoure project. Manual para muestreo en el reconocimiento mineral de Costa Rica: Proyecto Centroamericano de energia y recursos naturales (in English and Spanish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolivar, S.

    This manual describes field procedures for the collection of stream-sediment and rock samples as part of the Mineral Resource Assessment of Costa Rica. It provides guidelines to be followed by personnel collecting, treating, or otherwise handling samples taken as part of this program. The objectives of the manual are to ensure that all samples are collected uniformly and consistent techniques are employed throughout the program. If this is done, the data from this study can be used to identify areas with potential for mineralization. This manual can also be used as a guideline for future geochemical sampling programs in Costamore » Rica.« less

  19. --No Title--

    Science.gov Websites

    Search Search Home SH Reference Manual E19 Documentation Program Management Training/Drills Other Dataweb National Water Information System Database SH Reference Manual, E-19 Docs, Program Management

  20. Supported Employment Staff Training Manual.

    ERIC Educational Resources Information Center

    Inge, Katherine; And Others

    This training manual provides practical guidelines for staff development in supported employment programs for individuals with severe disabilities. It provides information on designing and developing training programs using adult learning principles, for program managers or trainers responsible for implementing inservice training and technical…

  1. Senior Citizen School Volunteer Program. A Manual for Program Implementation. Intergenerational Communication, No. 1.

    ERIC Educational Resources Information Center

    Kramer, Cynthia; Newman, Sally

    This manual provides background information about the Senior Citizen School Volunteer Program (SCSVP) and describes the program model that has been developed and implemented by the staff of Generations Together in more than 75 schools. The SCSVP develops intergenerational programs by involving older people as volunteers in elementary and secondary…

  2. MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, B; Kanal, K; Dickinson, R

    2014-06-15

    Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structuredmore » Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.« less

  3. [Statistical process control applied to intensity modulated radiotherapy pretreatment controls with portal dosimetry].

    PubMed

    Villani, N; Gérard, K; Marchesi, V; Huger, S; François, P; Noël, A

    2010-06-01

    The first purpose of this study was to illustrate the contribution of statistical process control for a better security in intensity modulated radiotherapy (IMRT) treatments. This improvement is possible by controlling the dose delivery process, characterized by pretreatment quality control results. So, it is necessary to put under control portal dosimetry measurements (currently, the ionisation chamber measurements were already monitored by statistical process control thanks to statistical process control tools). The second objective was to state whether it is possible to substitute ionisation chamber with portal dosimetry in order to optimize time devoted to pretreatment quality control. At Alexis-Vautrin center, pretreatment quality controls in IMRT for prostate and head and neck treatments were performed for each beam of each patient. These controls were made with an ionisation chamber, which is the reference detector for the absolute dose measurement, and with portal dosimetry for the verification of dose distribution. Statistical process control is a statistical analysis method, coming from industry, used to control and improve the studied process quality. It uses graphic tools as control maps to follow-up process, warning the operator in case of failure, and quantitative tools to evaluate the process toward its ability to respect guidelines: this is the capability study. The study was performed on 450 head and neck beams and on 100 prostate beams. Control charts, showing drifts, both slow and weak, and also both strong and fast, of mean and standard deviation have been established and have shown special cause introduced (manual shift of the leaf gap of the multileaf collimator). Correlation between dose measured at one point, given with the EPID and the ionisation chamber has been evaluated at more than 97% and disagreement cases between the two measurements were identified. The study allowed to demonstrate the feasibility to reduce the time devoted to pretreatment controls, by substituting the ionisation chamber's measurements with those performed with EPID, and also that a statistical process control monitoring of data brought security guarantee. 2010 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  4. Hanford Laboratories monthly activities report, February 1964

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1964-03-16

    This is the monthly report for the Hanford Laboratories Operation, February, 1964. Reactor fuels, chemistry, dosimetry, separation process, reactor technology financial activities, biology operation, physics and instrumentation research, employee relations, applied mathematics, programming, and radiation protection are discussed.

  5. Financial Reporting and Cost Analysis Manual for Day Care Centers, Head Start, and Other Programs.

    ERIC Educational Resources Information Center

    Bedger, Jean E.; And Others

    This manual is designed to provide fundamental directions for systematic financial reporting and cost analysis for the administrators, accountants, bookkeepers, and staff of day care, Project Head Start, and other programs. The major aims of the manual are to induce day care directors to adopt uniform bookkeeping procedures and to analyze costs…

  6. Healthy Young Children: A Manual for Programs, 4th Edition.

    ERIC Educational Resources Information Center

    Aronson, Susan S., Ed.

    Noting that the health component of child care should be planned to respond to the developmental patterns of young children, this manual was developed as a reference and resource guide for program directors and teachers of young children and can be used as a textbook for adult learners. The manual, based on national standards and reviewed by…

  7. Parenting Skills: A Trainer's Manual. A Performance Based Early Childhood-Special Education Teacher Preparation Program. Monograph 3.

    ERIC Educational Resources Information Center

    Abidin, Richard R.

    This manual, developed as part of the performance-based Early Childhood-Special Education Teacher Preparation Program, is a trainer's manual for teaching parenting skills. Each module or set of modules presents effective skills for managing and changing behaviors of adults and children. Several profession strategies and theoretical orientations…

  8. Improving Parent-Adolescent Relationships: Learning Activities for Parents and Adolescents. Leader Manual and Participant Workbook.

    ERIC Educational Resources Information Center

    Burnett, Darrell J.

    This leader manual and participant workbook present a 15 session program on parent-adolescent relationships. Three main topic areas are covered: perceiving each other (social perception); communicating effectively; and recognizing behavior as a function of its consequence. The leader manual presents an overview of the program which discusses its…

  9. Computer Processing 10-20-30. Teacher's Manual. Senior High School Teacher Resource Manual.

    ERIC Educational Resources Information Center

    Fisher, Mel; Lautt, Ray

    Designed to help teachers meet the program objectives for the computer processing curriculum for senior high schools in the province of Alberta, Canada, this resource manual includes the following sections: (1) program objectives; (2) a flowchart of curriculum modules; (3) suggestions for short- and long-range planning; (4) sample lesson plans;…

  10. Affective Education: A Teacher's Manual to Promote Student Self-Actualization and Human Relations Skills.

    ERIC Educational Resources Information Center

    Snyder, Thomas R.

    This teacher's manual presents affective education as a program to promote student self-actualization and human relations skills. Abraham Maslow's hierarchy of needs and Erik Erikson's life stages of psychosocial development form the conceptual base for this program. The goals and objectives of this manual are concerned with problem-solving…

  11. Sexuality and the Chemically Dependent Woman. A Group Facilitator's Guide.

    ERIC Educational Resources Information Center

    Covington, Stephanie S.

    This manual contains the first 2-hour session of a six-session sexuality guide designed for clinicians and facilitators working with chemically dependent women. The content of the manual is appropriate for inpatient programs, outpatient programs, and after-care groups. The manual begins with an introduction to women's sexuality in the 1980s and an…

  12. 1983-1984 Official Wisconsin Junior Dairymen's Association Manual. Bulletin No. 4097.

    ERIC Educational Resources Information Center

    Wisconsin State Dept. of Public Instruction, Madison. Bureau for Vocational Education.

    This manual contains information needed for conducting local chapters of the Wisconsin Junior Dairymen's Association program. Included in the manual is a summary of the year's program of work, lists of previous award winners, and rules for the many contests held annually by the association. Blank forms are provided for contest entry, association…

  13. 2005 Annual Health Physics Report for HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2006-04-21

    During the 2005 calendar year, LLNL provided health physics support for the Highly Enriched Uranium Transparency Program (HEU-TP) in external and internal radiation protection and technical expertise into matters related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2005, there were 161 person-trips that required dose monitoring of the U.S. monitors. Of the 161 person-trips, 149 person-trips were SMVs and 12 person-trips were Transparency Monitoring Office (TMO) trips. Additionally, there were 11 monitoring visits by TMO monitors to facilities other than UEIE and 3 to UEIE itself. There were two monitoring visits (source changes)more » that were back to back with 16 monitors. Each of these concurring visits were treated as single person-trips for dosimetry purposes. Counted individually, there were 191 individual person-visits in 2005. The LLNL Safety Laboratories Division provided the dosimetry services for the HEU-TP monitors.« less

  14. Resistance Training Reduces Force Tremor and Improves Manual Dexterity in Older Individuals With Essential Tremor.

    PubMed

    Kavanagh, Justin J; Wedderburn-Bisshop, Jacob; Keogh, Justin W L

    2016-01-01

    Although symptoms of Essential Tremor (ET) are typically controlled with medication, it is of interest to explore additional therapies to assist with functionality. The purpose of this study was to determine if a generalized upper limb resistance training (RT) program improves manual dexterity and reduces force tremor in older individuals with ET. Ten Essential Tremor and 9 controls were recruited into a dual group, pretest-posttest intervention study. Participants performed 6 weeks of upper-limb RT, and battery of manual dexterity and isometric force tremor assessments were performed before and after the RT to determine the benefits of the program. The six-week, high-load, RT program produced strength increases in each limb for the ET and healthy older group. These changes in strength aligned with improvements in manual dexterity and tremor-most notably for the ET group. The least affected limb and the most affected limb exhibited similar improvements in functional assessments of manual dexterity, whereas reductions in force tremor amplitude following the RT program were restricted to the most affected limb of the ET group. These findings suggest that generalized upper limb RT program has the potential to improve aspects of manual dexterity and reduce force tremor in older ET patients.

  15. Reactor Dosimetry State of the Art 2008

    NASA Astrophysics Data System (ADS)

    Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan

    2009-08-01

    Oral session 1: Retrospective dosimetry. Retrospective dosimetry of VVER 440 reactor pressure vessel at the 3rd unit of Dukovany NPP / M. Marek ... [et al.]. Retrospective dosimetry study at the RPV of NPP Greifswald unit 1 / J. Konheiser ... [et al.]. Test of prototype detector for retrospective neutron dosimetry of reactor internals and vessel / K. Hayashi ... [et al.]. Neutron doses to the concrete vessel and tendons of a magnox reactor using retrospective dosimetry / D. A. Allen ... [et al.]. A retrospective dosimetry feasibility study for Atucha I / J. Wagemans ... [et al.]. Retrospective reactor dosimetry with zirconium alloy samples in a PWR / L. R. Greenwood and J. P. Foster -- Oral session 2: Experimental techniques. Characterizing the Time-dependent components of reactor n/y environments / P. J. Griffin, S. M. Luker and A. J. Suo-Anttila. Measurements of the recoil-ion response of silicon carbide detectors to fast neutrons / F. H. Ruddy, J. G. Seidel and F. Franceschini. Measurement of the neutron spectrum of the HB-4 cold source at the high flux isotope reactor at Oak Ridge National Laboratory / J. L. Robertson and E. B. Iverson. Feasibility of cavity ring-down laser spectroscopy for dose rate monitoring on nuclear reactor / H. Tomita ... [et al.]. Measuring transistor damage factors in a non-stable defect environment / D. B. King ... [et al.]. Neutron-detection based monitoring of void effects in boiling water reactors / J. Loberg ... [et al.] -- Poster session 1: Power reactor surveillance, retrospective dosimetry, benchmarks and inter-comparisons, adjustment methods, experimental techniques, transport calculations. Improved diagnostics for analysis of a reactor pulse radiation environment / S. M. Luker ... [et al.]. Simulation of the response of silicon carbide fast neutron detectors / F. Franceschini, F. H. Ruddy and B. Petrović. NSV A-3: a computer code for least-squares adjustment of neutron spectra and measured dosimeter responses / J. G. Williams, A. P. Ribaric and T. Schnauber. Agile high-fidelity MCNP model development techniques for rapid mechanical design iteration / J. A. Kulesza.Extension of Raptor-M3G to r-8-z geometry for use in reactor dosimetry applications / M. A. Hunter, G. Longoni and S. L. Anderson. In vessel exposure distributions evaluated with MCNP5 for Atucha II / J. M. Longhino, H. Blaumann and G. Zamonsky. Atucha I nuclear power plant azimutal ex-vessel flux profile evaluation / J. M. Longhino ... [et al.]. UFTR thermal column characterization and redesign for maximized thermal flux / C. Polit and A. Haghighat. Activation counter using liquid light-guide for dosimetry of neutron burst / M. Hayashi ... [et al.]. Control rod reactivity curves for the annular core research reactor / K. R. DePriest ... [et al.]. Specification of irradiation conditions in VVER-440 surveillance positions / V. Kochkin ... [et al.]. Simulations of Mg-Ar ionisation and TE-TE ionisation chambers with MCNPX in a straightforward gamma and beta irradiation field / S. Nievaart ... [et al.]. The change of austenitic stainless steel elements content in the inner parts of VVER-440 reactor during operation / V. Smutný, J. Hep and P. Novosad. Fast neutron environmental spectrometry using disk activation / G. Lövestam ... [et al.]. Optimization of the neutron activation detector location scheme for VVER-lOOO ex-vessel dosimetry / V. N. Bukanov ... [et al.]. Irradiation conditions for surveillance specimens located into plane containers installed in the WWER-lOOO reactor of unit 2 of the South-Ukrainian NPP / O. V. Grytsenko. V. N. Bukanov and S. M. Pugach. Conformity between LRO mock-ups and VVERS NPP RPV neutron flux attenuation / S. Belousov. Kr. Ilieva and D. Kirilova. FLUOLE: a new relevant experiment for PWR pressure vessel surveillance / D. Beretz ... [et al.]. Transport of neutrons and photons through the iron and water layers / M. J. Kost'ál ... [et al.]. Condition evaluation of spent nuclear fuel assemblies from the first-generation nuclear-powered submarines by gamma scanning / A. F. Usatyi. L. A. Serdyukova and B. S. Stepennov -- Oral session 3: Power plant surveillance. Upgraded neutron dosimetry procedure for VVER-440 surveillance specimens / V. Kochkin ... [et al.]. Neutron dosimetry on the full-core first generation VVER-440 aimed to reactor support structure load evaluation / P. Borodkin ... [et al.]. Ex-vessel neutron dosimetry programs for PWRs in Korea / C. S. Yoo. B. C. Kim and C. C. Kim. Comparison of irradiation conditions of VVER-1000 reactor pressure vessel and surveillance specimens for various core loadings / V. N. Bukanov ... [et al.]. Re-evaluation of dosimetry in the new surveillance program for the Loviisa 1 VVER-440 reactor / T. Serén -- Oral session 4: Benchmarks, intercomparisons and adjustment methods. Determination of the neutron parameter's uncertainties using the stochastic methods of uncertainty propagation and analysis / G. Grégoire ... [et al.].Covariance matrices for calculated neutron spectra and measured dosimeter responses / J. G. Williams ... [et al.]. The role of dosimetry at the high flux reactor / S. C. van der Marek ... [et al.]. Calibration of a manganese bath relative to Cf-252 nu-bar / D. M. Gilliam, A. T. Yue and M. Scott Dewey. Major upgrade of the reactor dosimetry interpretation methodology used at the CEA: general principle / C. Destouches ... [et al.] -- Oral session 5: power plant surveillance. The role of ex-vessel neutron dosimetry in reactor vessel surveillance in South Korea / B.-C. Kim ... [et al.]. Spanish RPV surveillance programmes: lessons learned and current activities / A. Ballesteros and X. Jardí. Atucha I nuclear power plant extended dosimetry and assessment / H. Blaumann ... [et al.]. Monitoring of radiation load of pressure vessels of Russian VVER in compliance with license amendments / G. Borodkin ... [et al.] -- Poster session 2: Test reactors, accelerators and advanced systems; cross sections, nuclear data, damage correlations. Two-dimensional mapping of the calculated fission power for the full-size fuel plate experiment irradiated in the advanced test reactor / G. S. Chang and M. A. Lillo. The radiation safety information computational center: a resource for reactor dosimetry software and nuclear data / B. L. Kirk. Irradiated xenon isotopic ratio measurement for failed fuel detection and location in fast reactor / C. Ito, T. Iguchi and H. Harano. Characterization of dosimetry of the BMRR horizontal thimble tubes and broad beam facility / J.-P. Hu, R. N. Reciniello and N. E. Holden. 2007 nuclear data review / N. E. Holden. Further dosimetry studies at the Rhode Island nuclear science / R. N. Reciniello ... [et al.]. Characterization of neutron fields in the experimental fast reactor Joyo MK-III core / S. Maeda ... [et al.]. Measuring [symbol]Li(n, t) and [symbol]B(n, [symbol]) cross sections using the NIST alpha-gamma apparatus / M. S. Dewey ... [et al.]. Improvement of neutron/gamma field evaluation for restart of JMTR / Y. Nagao ... [et al.]. Monitoring of the irradiated neutron fluence in the neutron transmutation doping process of HANARO / M.-S. Kim and S.-J. Park.Training reactor VR-l neutron spectrum determination / M. Vins, A. Kolros and K. Katovsky. Differential cross sections for gamma-ray production by 14 MeV neutrons on iron and bismuth / V. M. Bondar ... [et al.]. The measurements of the differential elastic neutron cross-sections of carbon for energies from 2 to 133 ke V / O. Gritzay ... [et al.]. Determination of neutron spectrum by the dosimetry foil method up to 35 Me V / S. P. Simakov ... [et al.]. Extension of the BGL broad group cross section library / D. Kirilova, S. Belousov and Kr. Ilieva. Measurements of neutron capture cross-section for tantalum at the neutron filtered beams / O. Gritzayand V. Libman. Measurements of microscopic data at GELINA in support of dosimetry / S. Kopecky ... [et al.]. Nuclide guide and international chart of nuclides - 2008 / T. Golashvili -- Oral session 6: Test reactors, accelerators and advanced systems. Neutronic analyses in support of the HFIR beamline modifications and lifetime extension / I. Remec and E. D. Blakeman. Characterization of neutron test facilities at Sandia National Laboratories / D. W. Vehar ... [et al.]. LYRA irradiation experiments: neutron metrology and dosimetry / B. Acosta and L. Debarberis. Calculated neutron and gamma-ray spectra across the prismatic very high temperature reactor core / J. W. Sterbentz. Enhancement of irradiation capability of the experimental fast reactor joyo / S. Maeda ... [et al.]. Neutron spectrum analyses by foil activation method for high-energy proton beams / C. H. Pyeon ... [et al.] -- Oral session 7: Cross sections, nuclear data, damage correlations. Investigation of new reaction cross-section evaluations in order to update and extend the IRDF-2002 reactor dosimetry library / É. M. Zsolnay, H. J. Nolthenius and A. L. Nichols. A novel approach towards DPA calculations / A. Hogenbirk and D. F. Da Cruz. A new ENDFIB-VII.O based multigroup cross-section library for reactor dosimetry / F. A. Alpan and S. L. Anderson. Activities at the NEA for dosimetry applications / H. Henriksson and I. Kodeli. Validation and verification of covariance data from dosimetry reaction cross-section evaluations / S. Badikov. Status of the neutron cross section standards / A. D. Carlson -- Oral session 8: transport calculations. A dosimetry assessment for the core restraint of an advanced gas cooled reactor / D. A. Thornton ... [et al.]. Neutron dosimetry study in the region of the support structure of a VVER-1000 type reactor / G. Borodkin ... [et al.]. SNS moderator poison design and experiment validation of the moderator performance / W. Lu ... [et al.]. Analysis of OSIRIS in-core surveillance dosimetry for GONDOLE steel irradiation program by using TRIPOLI-4 Monte Carlo code / Y. K. Lee and F. Malouch.Reactor dosimetry applications using RAPTOR-M3G: a new parallel 3-D radiation transport code / G. Longoni and S. L. Anderson.

  16. --No Title--

    Science.gov Websites

    Search Search Home SH Reference Manual E19 Documentation Program Management Training/Drills Other River and Lake Summary (RVD) SH Reference Manual, E-19 Docs, Program Management, Training/Drills, Other

  17. User's manual for generalized ILSGLD-ILS glide slope performance prediction : multipath scattering

    DOT National Transportation Integrated Search

    1976-11-01

    This manual presents the computer program package for the generalized ILSGLD scattering model. The text includes a complete description of the program itself as well as 3 brief descriptions : of the ILS system and antenna patterns. The program listin...

  18. A Model to Predict Final Cost Growth in a Weapon System Development Program

    DTIC Science & Technology

    1975-08-01

    Manual Calculation ..... .............. ... 117 11. Data and Results of 3 x 2 Manual Calculation .................... .. 119 12. Quarterly F-5E... manually calculated. The data and results are in Table 10. The computer program for these calculations is listed in Figure 12 with results in Figure...13. Table 10 Data and Results of 2 x 2 Manual Calculation Outcome Aspect Poor Acceptable 1 .5 .5 2 .3 .7 The total number of events possible are: (2)2

  19. Image 100 procedures manual development: Applications system library definition and Image 100 software definition

    NASA Technical Reports Server (NTRS)

    Guseman, L. F., Jr.; Decell, H. P., Jr.

    1975-01-01

    An outline for an Image 100 procedures manual for Earth Resources Program image analysis was developed which sets forth guidelines that provide a basis for the preparation and updating of an Image 100 Procedures Manual. The scope of the outline was limited to definition of general features of a procedures manual together with special features of an interactive system. Computer programs were identified which should be implemented as part of an applications oriented library for the system.

  20. Program user's manual for optimizing the design of a liquid or gaseous propellant rocket engine with the automated combustor design code AUTOCOM

    NASA Technical Reports Server (NTRS)

    Reichel, R. H.; Hague, D. S.; Jones, R. T.; Glatt, C. R.

    1973-01-01

    This computer program manual describes in two parts the automated combustor design optimization code AUTOCOM. The program code is written in the FORTRAN 4 language. The input data setup and the program outputs are described, and a sample engine case is discussed. The program structure and programming techniques are also described, along with AUTOCOM program analysis.

  1. Outdoor Living Skills: Instructors Manual for Administering the OLS Program in a Camp and for Teaching the Program Leader Course. Revised Edition.

    ERIC Educational Resources Information Center

    American Camping Association, Martinsville, IN.

    This manual is designed as a tool for teaching and administering the Outdoor Living Skills (OLS) program in a camp and for training program leaders. Introductory sections address the following: (1) program overview and program materials; (2) people and their environment (physiological and psychological concerns of children and youth, understanding…

  2. Summer Splash. 1988 Wisconsin Summer Library Program Manual. Bulletin No. 8230.

    ERIC Educational Resources Information Center

    Lamb, Donald K.; And Others

    A compilation of materials contributed by and developed with the cooperation of Wisconsin librarians and Ohio's 1987 summer reading program, this planning manual provides guidelines for planning and promoting summer programs for young people by librarians in the state of Wisconsin. The theme of the program, "Summer Splash," is intended…

  3. Highway Safety Program Manual: Volume 11: Emergency Medical Services.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 11 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) concentrates on emergency medical services. The purpose of the program, Federal authority in the area of medical services, and policies related to an emergency medical services (EMS) program are…

  4. Highway Safety Program Manual: Volume 9: Identification and Surveillance of Accident Locations.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 9 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) focuses on identification and surveillance of accident locations. The purpose of the program, its specific objectives, and its relationship with other programs are explored. Federal authority in the…

  5. LOGSIM user's manual. [Logic Simulation Program for computer aided design of logic circuits

    NASA Technical Reports Server (NTRS)

    Mitchell, C. L.; Taylor, J. F.

    1972-01-01

    The user's manual for the LOGSIM Program is presented. All program options are explained and a detailed definition of the format of each input card is given. LOGSIM Program operations, and the preparation of LOGSIM input data are discused along with data card formats, postprocessor data cards, and output interpretation.

  6. Science 26: Teacher Resource Manual. Integrated Occupational Program. Interim 1991.

    ERIC Educational Resources Information Center

    Alberta Dept. of Education, Edmonton. Curriculum Branch.

    The Integrated Occupation Science 26 Program is an optional program designed to allow students in Alberta, Canada to meet the credit requirements of the Certificate of Achievement and facilitate transfer to the General High School Diploma Program. This Teacher Resource Manual is provided to assist classroom teachers to implement the Science 26…

  7. The Weatherization Assistant User's Manual (Version 8.9)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gettings, Michael B.; Malhotra, Mini; Ternes, Mark P.

    The Weatherization Assistant is a Windows-based energy audit software tool that was developed by Oak Ridge National Laboratory (ORNL) to help states and their local weatherization agencies implement the U.S. Department of Energy (DOE) Weatherization Assistance Program. The Weatherization Assistant is an umbrella program for two individual energy audits or measure selection programs: the National Energy Audit Tool (NEAT) for site-built single-family homes and the Manufactured Home Energy Audit (MHEA) for mobile homes. The Weatherization Assistant User's Manual documents the operation of the user interface for Version 8.9 of the software. This includes how to install and setup the software,more » navigate through the program, and initiate an energy audit. All of the user interface forms associated with the software and the data fields on these forms are described in detail. The manual is intended to be a training manual for new users of the Weatherization Assistant and as a reference manual for experienced users.« less

  8. Progress in high-dose radiation dosimetry. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expended applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Requirements for a stable and reliable transfer dose meters have led to further developments of several important high-dose systems: thermoluminescent materials, radiochromic dyes, ceric-cerous solutions analyzed by high-frequency oscillometry. A number of other prospective dosimeters are also treated in this review. In addition, an IAEA program of high-dose intercomparison and standardization for industrial radiation processing is described.

  9. AIS training manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kramer, C.F.; Barancik, J.I.

    1989-05-01

    This Training Manual was developed by the Injury Prevention and Analysis Group (IPAG) as part of a training program in AIS 85 and AIS-EM (Epidemiological Modifications) coding. The IPAG Program is designed primarily to train medical record and other health professionals from diverse backgrounds and experience levels in the use of AIS 85 and AIS 85-EM. The Manual is designed to be used as a reference text after completion of the Program and includes copies of visual projection materials used during the training sessions.

  10. Tutor Training Program.

    ERIC Educational Resources Information Center

    Gill, Wanda E.

    A tutor training program manual that is used at Bowie State College is presented. The manual covers the following: tutoring program objectives; general tutoring principles; general procedures the tutor should follow; including contacting the student and establishing rapport, guidelines concerning the tutors' attitudes and behavior; a few points to…

  11. DOD-Wide Civilian Career Program for Procurement Personnel.

    ERIC Educational Resources Information Center

    Office of the Assistant Secretary of Defense for Manpower and Reserve Affairs (DOD), Washington, DC.

    The manual, which supersedes the August 4, 1966 manual, is designed to aid in program improvement for career development and advancement opportunities of Department of Defense (DOD) civilian procurement personnel. Program elements covered include: career patterns, career counseling and appraisal, training and development, registration, referral…

  12. ESPVI 4.0 ELECTROSTATIS PRECIPITATOR V-1 AND PERFORMANCE MODEL: USER'S MANUAL

    EPA Science Inventory

    The manual is the companion document for the microcomputer program ESPVI 4.0, Electrostatic Precipitation VI and Performance Model. The program was developed to provide a user- friendly interface to an advanced model of electrostatic precipitation (ESP) performance. The program i...

  13. Steady, oscillatory, and unsteady subsonic Aerodynamics, production version 1.1 (SOUSSA-P1.1). Volume 2: User/programmer manual

    NASA Technical Reports Server (NTRS)

    Smolka, S. A.; Preuss, R. D.; Tseng, K.; Morino, L.

    1980-01-01

    A user/programmer manual for the computer program SOUSSA P 1.1 is presented. The program was designed to provide accurate and efficient evaluation of steady and unsteady loads on aircraft having arbitrary shapes and motions, including structural deformations. These design goals were in part achieved through the incorporation of the data handling capabilities of the SPAR finite element Structural Analysis computer program. As a further result, SOUSSA P possesses an extensive checkpoint/ restart facility. The programmer's portion of this manual includes overlay/subroutine hierarchy, logical flow of control, definition of SOUSSA P 1.1 FORTRAN variables, and definition of SOUSSA P 1.1 subroutines. Purpose of the SOUSSA P 1.1 modules, input data to the program, output of the program, hardware/software requirements, error detection and reporting capabilities, job control statements, a summary of the procedure for running the program and two test cases including input and output and listings are described in the user oriented portion of the manual.

  14. Corporate Functional Management Evaluation of the LLNL Radiation Safety Organization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sygitowicz, L S

    2008-03-20

    A Corporate Assess, Improve, and Modernize review was conducted at Lawrence Livermore National Laboratory (LLNL) to evaluate the LLNL Radiation Safety Program and recommend actions to address the conditions identified in the Internal Assessment conducted July 23-25, 2007. This review confirms the findings of the Internal Assessment of the Institutional Radiation Safety Program (RSP) including the noted deficiencies and vulnerabilities to be valid. The actions recommended are a result of interviews with about 35 individuals representing senior management through the technician level. The deficiencies identified in the LLNL Internal Assessment of the Institutional Radiation Safety Program were discussed with Radiationmore » Safety personnel team leads, customers of Radiation Safety Program, DOE Livermore site office, and senior ES&H management. There are significant issues with the RSP. LLNL RSP is not an integrated, cohesive, consistently implemented program with a single authority that has the clear roll and responsibility and authority to assure radiological operations at LLNL are conducted in a safe and compliant manner. There is no institutional commitment to address the deficiencies that are identified in the internal assessment. Some of these deficiencies have been previously identified and corrective actions have not been taken or are ineffective in addressing the issues. Serious funding and staffing issues have prevented addressing previously identified issues in the Radiation Calibration Laboratory, Internal Dosimetry, Bioassay Laboratory, and the Whole Body Counter. There is a lack of technical basis documentation for the Radiation Calibration Laboratory and an inadequate QA plan that does not specify standards of work. The Radiation Safety Program lack rigor and consistency across all supported programs. The implementation of DOE Standard 1098-99 Radiological Control can be used as a tool to establish this consistency across LLNL. The establishment of a site wide ALARA Committee and administrative control levels would focus attention on improved processes. Currently LLNL issues dosimeters to a large number of employees and visitors that do not enter areas requiring dosimetry. This includes 25,000 visitor TLDs per year. Dosimeters should be issued to only those personnel who enter areas where dosimetry is required.« less

  15. Image processing for IMRT QA dosimetry.

    PubMed

    Zaini, Mehran R; Forest, Gary J; Loshek, David D

    2005-01-01

    We have automated the determination of the placement location of the dosimetry ion chamber within intensity-modulated radiotherapy (IMRT) fields, as part of streamlining the entire IMRT quality assurance process. This paper describes the mathematical image-processing techniques to arrive at the appropriate measurement locations within the planar dose maps of the IMRT fields. A specific spot within the found region is identified based on its flatness, radiation magnitude, location, area, and the avoidance of the interleaf spaces. The techniques used include applying a Laplacian, dilation, erosion, region identification, and measurement point selection based on three parameters: the size of the erosion operator, the gradient, and the importance of the area of a region versus its magnitude. These three parameters are adjustable by the user. However, the first one requires tweaking in extremely rare occasions, the gradient requires rare adjustments, and the last parameter needs occasional fine-tuning. This algorithm has been tested in over 50 cases. In about 5% of cases, the algorithm does not find a measurement point due to the extremely steep and narrow regions within the fluence maps. In such cases, manual selection of a point is allowed by our code, which is also difficult to ascertain, since the fluence map does not yield itself to an appropriate measurement point selection.

  16. Roadmap Through Title XX. Financing Services for Children Through Title XX and Other Programs: Manual 5.

    ERIC Educational Resources Information Center

    Copeland, William C.; Iversen, Iver A.

    This manual, part of a Hecht Institute four-manual series entitled Financing Children's Services Through Title XX and Related Programs, teaches what Title XX regulations are, what they mean, and what actions and procedures are commanded by them. The first section covers the necessity of rule systems, the characteristics of a good rule system and…

  17. Blue Sky Below My Feet: Daycamp & After School Programs--9 to 11 Year Olds. Leader's Manual.

    ERIC Educational Resources Information Center

    California Univ., Berkeley. Cooperative Extension Service.

    This manual presents a 10-day lesson plan for day camp and after-school program leaders. The activities and experiments described in the manual focus on nutrition and space exploration. Topics covered by the lesson plan and specific projects include: (1) gravity; (2) food spoilage; (3) model rocket building and launching; (4) the basic food…

  18. The Private Sector Youth Connection. Volume 1: School to Work. A Planning Manual for Educators and Business People.

    ERIC Educational Resources Information Center

    Schilit, Henrietta; Lacey, Richard

    This manual profiles 55 school-business cooperative programs being carried out in the United States for the purpose of improving access to employment for high school students, particularly minorities and the economically disadvantaged, before they graduate. Each of the manual's chapters is devoted to a particular type of cooperative program and…

  19. Alternative Funding Resources Manual for Drug Abuse and Alcohol Treatment and Rehabilitation Programs.

    ERIC Educational Resources Information Center

    Bertagnoli, Cliff

    The purpose of this manual is to guide and assist alcohol and other drug abuse treatment programs to maximize cost recovery from third party reimbursements. It is intended to be a guide for planning and decision making rather than a resource manual. The text is based on the experiences of agencies in six states participating in a demonstration…

  20. Intrasystem Electromagnetic Compatibility Analysis Program. Volume 2. User’s Manual Usage Section

    DTIC Science & Technology

    1974-12-01

    AD-A008 527 INTRASYSTEM ELECTROMAGNETIC COMPATI- BILITY ANALYSIS PROGRAM. VOLUME II.USER’S MANUAL USAGE SECTION J. L. Bogdanor , et al McDonnell...NUMBERVolume II - User’s Manual Usage Section None 7. AUTHOR(&) 8. CONTRACT OR GRANT NUMBER(s) J.L. Bogdanor F30602-72-C-0277 R.A. Pearlman M.D. Siegel

  1. Hanford Laboratories Operation monthly activities report, September 1961

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1961-10-16

    This is the monthly report for the Hanford Laboratories Operation September 1961. Reactor fuels, chemistry, dosimetry, separation processes, reactor technology, financial activities, biology operation, physics and instrumentation research, operations research and synthesis, programming, and radiation protection operation are discussed.

  2. Historic American engineering record. Nevada national security site, Bren Tower Complex. Written historical and descriptive data and field records

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, Susan R.; Goldenberg, Nancy

    The BREN (Bare Reactor Experiment, Nevada) Tower Complex is significant for its role in the history of nuclear testing, radiation dosimetry studies, and early field testing of the Strategic Missile Defense System designs. At the time it was built in 1962, the 1,527 ft (465 m) BREN Tower was the tallest structure west of the Mississippi River and exceeded the height of the Empire State Building by 55 ft (17 m). It remains the tallest ever erected specifically for scientific purposes and was designed and built to facilitate the experimental dosimetry studies necessary for the development of accurate radiation dosemore » rates for the survivors of Hiroshima and Nagasaki. The tower was a key component of the Atomic Bomb Casualty Commission’s (ABCC) mission to predict the health effects of radiation exposure. Moved to its current location in 1966, the crucial dosimetry studies continued with Operation HENRE (High Energy Neutron Reactions Experiment). These experiments and the data they generated became the basis for a dosimetry system called the Tentative 1965 Dose or more commonly the T65D model. Used to estimate radiation doses received by individuals, the T65D model was applied until the mid-1980s when it was replaced by a new dosimetry system known as DS86 based on the Monte Carlo method of dose rate calculation. However, the BREN Tower data are still used for verification of the validity of the DS86 model. In addition to its importance in radiation heath effects research, the BREN Tower Complex is also significant for its role in the Brilliant Pebbles research project, a major component of the Strategic Defense Initiative popularly known as the “Star Wars” Initiative. Instigated under the Reagan Administration, the program’s purpose was to develop a system to shield the United States and allies from a ballistic missile attack. The centerpiece of the Strategic Defense System was space-based, kinetic-kill vehicles. In 1991, BREN Tower was used for the tether tests of the Brilliant Pebbles prototype vehicle at the earth’s surface prior to the more costly space testing program. The success of these tests established the Brilliant Pebbles program as an essential component of America’s space-based missile defense system even after the dismantling of the Soviet Union. Data from the Brilliant Pebbles research program continues to inspire current missile defense system research (Independent Working Group 2009).« less

  3. Shriners Hospital Spinal Cord Injury Self Care Manual.

    ERIC Educational Resources Information Center

    Fox, Carol

    This manual is intended for young people with spinal cord injuries who are receiving rehabilitation services within the Spinal Cord Injury Unit at Shriners Hospital (San Francisco, California). An introduction describes the rehabilitation program, which includes family conferences, an individualized program, an independent living program,…

  4. 45 CFR 205.70 - Availability of agency program manuals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 2 2014-10-01 2012-10-01 true Availability of agency program manuals. 205.70 Section 205.70 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  5. 45 CFR 205.70 - Availability of agency program manuals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 2 2012-10-01 2012-10-01 false Availability of agency program manuals. 205.70 Section 205.70 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  6. DORCA 2 computer program. Volume 2: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Gold, B. J.

    1972-01-01

    A guide for coding the Dynamic Operational Requirements and Cost Analysis Program (DORCA 2) is presented. The manual provides a detailed operation of every subroutine, the layout in core of the major matrices and arrays, and the meaning of all program values. Flow charts are included.

  7. Solid rocket booster performance evaluation model. Volume 2: Users manual

    NASA Technical Reports Server (NTRS)

    1974-01-01

    This users manual for the solid rocket booster performance evaluation model (SRB-II) contains descriptions of the model, the program options, the required program inputs, the program output format and the program error messages. SRB-II is written in FORTRAN and is operational on both the IBM 370/155 and the MSFC UNIVAC 1108 computers.

  8. Dare To Be You Program. Leaders' Manual. 2nd Edition.

    ERIC Educational Resources Information Center

    Miller-Heyl, Janet Lynne; Shores, Wanda, Ed.

    This manual contains a complete set of program formats, activities, and references covered by the Dare to be You Training Program. The program, piloted in a rural Colorado County, is designed for use by parents, youth, teachers, church, and service organizations to help them deal with adolescents' problems and to assist youth in developing skills…

  9. Reading Roundup: Rope a Good Book. Louisiana Summer Reading Program, 1995 Manual.

    ERIC Educational Resources Information Center

    White, Dorothy, J., Ed.

    A manual for the Louisiana Summer Reading Program is presented in 14 sections with a western theme and illustrations. An evaluation form, a 1995 calendar, and a list of audiovisual materials with addresses and prices are also provided. Section 1 discusses promotion, publicity, and programs; and includes sample news releases; program ideas, and…

  10. 45 CFR 205.70 - Availability of agency program manuals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (AABD) of the Social Security Act must provide that: (a) Program manuals and other policy issuances... hours by individuals, upon request for review, study, or reproduction by the individual. (b)(1) A...

  11. 45 CFR 205.70 - Availability of agency program manuals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (AABD) of the Social Security Act must provide that: (a) Program manuals and other policy issuances... hours by individuals, upon request for review, study, or reproduction by the individual. (b)(1) A...

  12. Pennsylvania Blue Shield Job Linked Skills Program. Teacher's Manual [and] Technical Manual.

    ERIC Educational Resources Information Center

    Pennsylvania State Univ., University Park. Inst. for the Study of Adult Literacy.

    Two closely related publications from the same project, a Teacher's Manual" and a "Technical Manual", are combined here. These manuals are intended to accompany a work force literacy course designed to meet the basic skills needs of midliterate adults employed or preparing for employment in the health insurance industry.…

  13. Description of a computer program to calculate reacting supersonic internal flow fields with shock waves using viscous characteristics: Program manual and sample calculations

    NASA Technical Reports Server (NTRS)

    Cavalleri, R. J.; Agnone, A. M.

    1972-01-01

    A computer program for calculating internal supersonic flow fields with chemical reactions and shock waves typical of supersonic combustion chambers with either wall or mid-stream injectors is described. The usefulness and limitations of the program are indicated. The program manual and listing are presented along with a sample calculation.

  14. A Model for Developing a Continuous Progress Program, April 1977. A Manual for Teachers and Administrators Concerned with Improving Reading.

    ERIC Educational Resources Information Center

    Goldman, Rosalie; And Others

    The focus of this manual is on the step-by-step development and implementation of a continuous-progress reading program--a system that permits instruction at each student's diagnosed level of ability. Analysis of program development includes advice on choosing a committee, writing the program, and presenting the program to others. The implications…

  15. Effect of Adding Interferential Current in an Exercise and Manual Therapy Program for Patients With Unilateral Shoulder Impingement Syndrome: A Randomized Clinical Trial.

    PubMed

    Gomes, Cid André Fidelis de Paula; Dibai-Filho, Almir Vieira; Moreira, William Arruda; Rivas, Shirley Quispe; Silva, Emanuela Dos Santos; Garrido, Ana Claudia Bogik

    The purpose of this study was to measure the additional effect of adding interferential current (IFC) to an exercise and manual therapy program for patients with unilateral shoulder impingement syndrome. Forty-five participants were randomly assigned to group 1 (exercise and manual therapy), group 2 (exercise and manual therapy + IFC), or group 3 (exercise and manual therapy + placebo ultrasound). Individuals participated in 16 treatment sessions, twice a week for 8 weeks. The primary outcome of the study was total score of the Shoulder Pain and Disability Index (SPADI). The secondary outcomes were the pain and disability subscales of SPADI, Numeric Rating Scale, and Pain-Related Self-Statement Scale. Adjusted between-group mean differences (MDs) and 95% confidence intervals (CIs) were calculated using linear mixed models. After 16 treatment sessions, statistically significant but not clinically important differences were identified in favor of the exercise and manual therapy program alone in the SPADI-total (group 1 vs group 2, MD 11.12 points, 95% CI 5.90-16.35; group 1 vs group 3, MD 13.43 points, 95% CI 8.21-18.65). Similar results were identified for secondary outcomes. The addition of IFC does not generate greater clinical effects in an exercise and manual therapy program for individuals with unilateral shoulder impingement syndrome. Copyright © 2018. Published by Elsevier Inc.

  16. Long Term Resource Monitoring Program procedures: fish monitoring

    USGS Publications Warehouse

    Ratcliff, Eric N.; Glittinger, Eric J.; O'Hara, T. Matt; Ickes, Brian S.

    2014-01-01

    This manual constitutes the second revision of the U.S. Army Corps of Engineers’ Upper Mississippi River Restoration-Environmental Management Program (UMRR-EMP) Long Term Resource Monitoring Program (LTRMP) element Fish Procedures Manual. The original (1988) manual merged and expanded on ideas and recommendations related to Upper Mississippi River fish sampling presented in several early documents. The first revision to the manual was made in 1995 reflecting important protocol changes, such as the adoption of a stratified random sampling design. The 1995 procedures manual has been an important document through the years and has been cited in many reports and scientific manuscripts. The resulting data collected by the LTRMP fish component represent the largest dataset on fish within the Upper Mississippi River System (UMRS) with more than 44,000 collections of approximately 5.7 million fish. The goal of this revision of the procedures manual is to document changes in LTRMP fish sampling procedures since 1995. Refinements to sampling methods become necessary as monitoring programs mature. Possible refinements are identified through field experiences (e.g., sampling techniques and safety protocols), data analysis (e.g., planned and studied gear efficiencies and reallocations of effort), and technological advances (e.g., electronic data entry). Other changes may be required because of financial necessity (i.e., unplanned effort reductions). This version of the LTRMP fish monitoring manual describes the most current (2014) procedures of the LTRMP fish component.

  17. Effective Proposal Development. A How-To Manual for Skills Training Programs.

    ERIC Educational Resources Information Center

    Bohnen, Elizabeth D.

    This manual outlines effective program planning and proposal development techniques for preemployment and employment-related training programs. It is intended for use by staff of community organizations, business and industry, labor unions, social service agencies, and educational institutions. Section I is an introduction. Section II describes…

  18. ILLIAC 4 systems characteristics and programming manual

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The latest edition is presented of the Systems Characteristics and Programming Manual of the ILLIAC 4 array and parallel disc memory system. The major aspects of the array described include: the array systems characteristics, programming characteristics, definition and flow charts, and timing. A glossary of terms, and an instruction index are included.

  19. No Limits--READ! Young Adult Reading Club and Programming Manual.

    ERIC Educational Resources Information Center

    Youngblood, Lisa

    This manual provides strategies for developing young adult collections, outlines a reading club designed specifically for young adults, suggests promotional ideas for the young adult reading club and young adult programming in general, and provides age-appropriate ideas for both formal and passive programming. Specific topics covered in the…

  20. Manual for physical fitness

    NASA Technical Reports Server (NTRS)

    Coleman, A. E.

    1981-01-01

    Training manual used for preflight conditioning of NASA astronauts is written for audience with diverse backgrounds and interests. It suggests programs for various levels of fitness, including sample starter programs, safe progression schedules, and stretching exercises. Related information on equipment needs, environmental coonsiderations, and precautions can help readers design safe and effective running programs.

  1. Meal Counting and Claiming Manual.

    ERIC Educational Resources Information Center

    Food and Nutrition Service (USDA), Washington, DC.

    This manual contains information about the selection and implementation of a meal counting and claiming system for the National School Lunch Program (NSLP) and the School Breakfast Program (BSP). Federal reimbursement is provided for each meal that meets program requirements and is served to an eligible student. Part 1 explains the six elements of…

  2. Vocational Education Safety Instruction Manual.

    ERIC Educational Resources Information Center

    Cropley, Russell, Ed.; Doherty, Susan Sloan, Ed.

    This manual describes four program areas in vocational education safety instruction: (1) introduction to a safety program; (2) resources to ensure laboratory safety; (3) safety program implementation; and (4) safety rules and safety tests. The safety rules and tests included in section four are for the most common tools and machines used in…

  3. METal matrix composite ANalyzer (METCAN): Theoretical manual

    NASA Technical Reports Server (NTRS)

    Murthy, P. L. N.; Chamis, C. C.

    1993-01-01

    This manuscript is intended to be a companion volume to the 'METCAN User's Manual' and the 'METAN Demonstration Manual.' The primary purpose of the manual is to give details pertaining to micromechanics and macromechanics equations of high temperature metal matrix composites that are programmed in the METCAN computer code. The subroutines which contain the programmed equations are also mentioned in order to facilitate any future changes or modifications that the user may intend to incorporate in the code. Assumptions and derivations leading to the micromechanics equations are briefly mentioned.

  4. Aircraft noise prediction program user's manual

    NASA Technical Reports Server (NTRS)

    Gillian, R. E.

    1982-01-01

    The Aircraft Noise Prediction Program (ANOPP) predicts aircraft noise with the best methods available. This manual is designed to give the user an understanding of the capabilities of ANOPP and to show how to formulate problems and obtain solutions by using these capabilities. Sections within the manual document basic ANOPP concepts, ANOPP usage, ANOPP functional modules, ANOPP control statement procedure library, and ANOPP permanent data base. appendixes to the manual include information on preparing job decks for the operating systems in use, error diagnostics and recovery techniques, and a glossary of ANOPP terms.

  5. Competency-Based Adult Basic Education Manual for Level I (0-4.9) and Level II (5-8). A Training Manual for CBABE Instruction and Program Management.

    ERIC Educational Resources Information Center

    Singer, Elizabeth; And Others

    This training manual was developed as a source of information about Competency-Based Adult Basic Education (CBABE) for administrators, counselors, and teachers involved in the implementation of a CBABE program. After section I provides an introduction to Brevard Community College's development of CBABE curricula, section II explains the purposes…

  6. 77 FR 8183 - Restructuring of the Office of Programs; Elimination of Regional Offices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... public. * * * * * (d) * * * (1) In the Office of Programs/Operations: The Retirement Claims Manual, RCM... adjudication of claims not contained in the Retirement Claims Manual or in RCM Circulars, Field Operating...

  7. Pacific Northwest Laboratory annual report for 1988 to the DOE Office of Energy Research: Part 4, Physical sciences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Touburen, L.H.

    1989-03-01

    This document contains brief descriptions of various research programs in the physical science. Topics include Chernobyl Information Management, Supercritical Fluids, Laser Spectroscopy, DNA Adducts, Dosimetry, Biophysics, and Genetic Damage. (TEM)

  8. Computer program development and user's manual for program PARACH. [to investigate parachute spent solid rocket booster during terminal descent

    NASA Technical Reports Server (NTRS)

    Murphree, H. I.

    1979-01-01

    A user's manual is provided for program PARACH, a FORTRAN digital computer program operational on the Univac 1108. A description of the program and operating instructions for it are included. Program PARACH is used to study the interaction dynamics of a parachute and its payload during terminal descent. Operating instructions, required input data, program options and limitations, and output data are described. Subroutines used in this program are also listed and explained.

  9. Modifications to the streamtube curvature program. Volume 1: Program modifications and user's manual. [user manuals (computer programs) for transonic flow of nacelles and intake systems of turbofan engines

    NASA Technical Reports Server (NTRS)

    Ferguson, D. R.; Keith, J. S.

    1975-01-01

    The improvements which have been incorporated in the Streamtube Curvature Program to enhance both its computational and diagnostic capabilities are described. Detailed descriptions are given of the revisions incorporated to more reliably handle the jet stream-external flow interaction at trailing edges. Also presented are the augmented boundary layer procedures and a variety of other program changes relating to program diagnostics and extended solution capabilities. An updated User's Manual, that includes information on the computer program operation, usage, and logical structure, is presented. User documentation includes an outline of the general logical flow of the program and detailed instructions for program usage and operation. From the standpoint of the programmer, the overlay structure is described. The input data, output formats, and diagnostic printouts are covered in detail and illustrated with three typical test cases.

  10. Market analysis and program for use for energy conservation manuals: a marketing plan. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1977-02-25

    The FEA, with a mission to analyze total national energy usage, formulate policy, and stimulate actions that will increase domestic energy supply and decrease energy demand, decided to develop effective energy conservation manuals for decision makers in existing buildings. The manuals developed are: Building Owner's and Manager's Guide to Energy Conservation; Building Operator's Guide to Energy Conservation; and Architect's and Engineer's Guide to Energy Conservation. The background and scope of the entire project which led to the development of the manuals is discussed in the introduction of this publication. Part II, Market Analysis, provides insight into the character of themore » designated audiences for the manuals. Part III, Program for Use, is a marketing and promotion plan for the manuals.« less

  11. School-based prevention of bullying and relational aggression in adolescence: the fairplayer.manual.

    PubMed

    Scheithauer, Herbert; Hess, Markus; Schultze-Krumbholz, Anja; Bull, Heike Dele

    2012-01-01

    The fairplayer.manual is a school-based program to prevent bullying. The program consists of fifteen to seventeen consecutive ninety-minute lessons using cognitive-behavioral methods, methods targeting group norms and group dynamics, and discussions on moral dilemmas. Following a two-day training session, teachers, together with skilled fairplayer.teamers, implement fairplayer.manual in the classroom during regular school lessons. This chapter offers a summary of the program's conception and underlying prevention theory and summarizes the results from two evaluation studies. Standardized questionnaires showed a positive impact of the intervention program on several outcome variables. Copyright © 2012 Wiley Periodicals, Inc., A Wiley Company.

  12. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  13. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  14. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  15. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  16. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  17. Computer programs to characterize alloys and predict cyclic life using the total strain version of strainrange partitioning: Tutorial and users manual, version 1.0

    NASA Technical Reports Server (NTRS)

    Saltsman, James F.

    1992-01-01

    This manual presents computer programs for characterizing and predicting fatigue and creep-fatigue resistance of metallic materials in the high-temperature, long-life regime for isothermal and nonisothermal fatigue. The programs use the total strain version of Strainrange Partitioning (TS-SRP). An extensive database has also been developed in a parallel effort. This database is probably the largest source of high-temperature, creep-fatigue test data available in the public domain and can be used with other life prediction methods as well. This users manual, software, and database are all in the public domain and are available through COSMIC (382 East Broad Street, Athens, GA 30602; (404) 542-3265, FAX (404) 542-4807). Two disks accompany this manual. The first disk contains the source code, executable files, and sample output from these programs. The second disk contains the creep-fatigue data in a format compatible with these programs.

  18. Long-term pavement performance program manual for profile measurements and processing

    DOT National Transportation Integrated Search

    2008-11-01

    This manual describes operational procedures for measuring longitudinal pavement profiles for the Long-Term Pavement Performance (LTPP) Program using the International Cybernetics Corporation (ICC) road profiler, Face Company Dipstick, and the rod an...

  19. Highway Safety Program Manual: Volume 12: Highway Design, Construction and Maintenance.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 12 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) focuses on highway design, construction and maintenance. The purpose and specific objectives of such a program are described. Federal authority in the area of highway safety and policies regarding…

  20. REFERENCE MANUAL FOR RASSMIT VERSION 2.1: SUB-SLAB DEPRESSURIZATION SYSTEM DESIGN PERFORMANCE SIMULATION PROGRAM

    EPA Science Inventory

    The report is a reference manual for RASSMlT Version 2.1, a computer program that was developed to simulate and aid in the design of sub-slab depressurization systems used for indoor radon mitigation. The program was designed to run on DOS-compatible personal computers to ensure ...

  1. A Resource Manual on Child Abuse: PACER'S Let's Prevent Abuse Program.

    ERIC Educational Resources Information Center

    Garfinkel, Lili; And Others

    The resource manual developed by the Parent Advocacy Coalition for Educational Rights (PACER) in Minneapolis is intended to provide trainers of parents of handicapped children with information and resources concerning the prevention and treatment of child abuse. The PACER program has developed a program using child-sized puppets to teach…

  2. Computer Program (HEVSIM) for Heavy Duty Vehicle Fuel Economy and Performance Simulation. Volume II: Users' Manual.

    DOT National Transportation Integrated Search

    1981-09-01

    Volume II is the second volume of a three volume document describing the computer program HEVSIM for use with buses and heavy duty trucks. This volume is a user's manual describing how to prepare data input and execute the program. A strong effort ha...

  3. ESEA Title I Migrant Administration Manual Project Preparation and Program Management.

    ERIC Educational Resources Information Center

    Seurynck, John L.; Hicks, Garlin A.

    The manual outlines information on design and operation of the ESEA (Elementary and Secondary Education Act) Title I Migrant Education Program at the state and local levels. Part I outlines information on the state level: legislative authorization and general responsibilities of the state education agency (SEA); annual program plan and budget;…

  4. Parenting Education: An Exemplary Program for Rural/Migrant Youth and Adults. Final Report.

    ERIC Educational Resources Information Center

    Baum, Rosemere; And Others

    Designed for use in a parenting education course for rural/migrant youth and adults, this parenting education learning kit consists of a coordinator's manual and bilingual instructional materials for seven course sessions. Issues addressed in the coordinator's manual include program content, program format, orientation for experienced parents,…

  5. Default Management Manual.

    ERIC Educational Resources Information Center

    Dent, Richard A.

    This manual is designed to instruct administrators of the Guaranteed Student Loan (GSL) Program in how to take every step possible to administer the program effectively and to minimize the program costs of serving the high risk student. It shows schools how to work with students throughout their time in school, create ownership of the loan(s) by…

  6. Computer program user's manual for advanced general aviation propeller study

    NASA Technical Reports Server (NTRS)

    Worobel, R.

    1972-01-01

    A user's manual is presented for a computer program for predicting the performance (static, flight, and reverse), noise, weight and cost of propellers for advanced general aviation aircraft of the 1980 time period. Complete listings of this computer program with detailed instructions and samples of input and output are included.

  7. Eligibility Manual for School Meals: Federal Policy for Determining and Verifying Eligibility

    ERIC Educational Resources Information Center

    US Department of Agriculture, 2008

    2008-01-01

    This manual contains information on Federal requirements regarding the determination and verification of eligibility for free and reduced price meals in the National School Lunch Program and the School Breakfast Program. These provisions also apply to the determination of eligibility for free milk under the Special Milk Program and are generally…

  8. Highway Safety Program Manual: Volume 14: Pedestrian Safety.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 14 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) concentrates on pedestrian safety. The purpose and objectives of a pedestrian safety program are outlined. Federal authority in the area of pedestrian safety and policies regarding a safety program…

  9. Highway Safety Program Manual: Volume 15: Police Traffic Services.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 15 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) focuses on police traffic services. The purpose and objectives of a police services program are described. Federal authority in the areas of highway safety and policies regarding a police traffic…

  10. Manned systems utilization analysis (study 2.1). Volume 4: Program manual and users guide for the LOVES computer code

    NASA Technical Reports Server (NTRS)

    Wray, S. T., Jr.

    1975-01-01

    Information necessary to use the LOVES computer program in its existing state or to modify the program to include studies not properly handled by the basic model is provided. A users guide, a programmers manual, and several supporting appendices are included.

  11. Local Special Education Planning Model: User's Manual.

    ERIC Educational Resources Information Center

    Hartman, Peggy L.; Hartman, William T.

    To help school districts estimate the present and future needs and costs of their special education programs, this manual presents the Local Special Education Planning Model, an interactive computer program (with worksheets) that provides a framework for using a district's own data to analyze its special education program. Part 1 of the manual…

  12. Space tug automatic docking control study. LOCDOK users manual

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A users's manual for the computer programs involved in a study of the space tug docking simulation is presented. The following subjects are considered: (1) subroutine narratives, (2) program elements, (3) system subroutines, and (4) Univac 1108 cross reference listing. The functional and operational requirements for the computer programming are explained.

  13. Highway Safety Program Manual: Volume 6: Codes and Laws.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 6 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred safety practices) concentrates on codes and laws. The purpose and specific objectives of the Codes and Laws Program, Federal authority in the area of highway safety, and policies regarding traffic regulation are described.…

  14. Highway Safety Program Manual: Volume 3: Motorcycle Safety.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 3 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) concentrates on aspects of motorcycle safety. The purpose and specific objectives of a State motorcycle safety program are outlined. Federal authority in the highway safety area and general policies…

  15. Dental Hygiene Program Clinic Manual, Fall 1997. Fourth Edition.

    ERIC Educational Resources Information Center

    Errico, Mary; Cama, Christine; Pastoriza-Maldonado, Alida

    This is the fourth edition of the Clinic Manual for the Dental Hygiene Program at Eugenio Maria de Hostos Community College in the Bronx (New York). It contains general information, grading procedures, performance guides, and clinical forms related to the program. Section 1 provides an introduction to clinic philosophy, policies, goals and…

  16. Curriculum Guide and Activities Manual. A Preschool Program for Disadvantaged and Migrant Children.

    ERIC Educational Resources Information Center

    Ousterhout, William K.; And Others

    Designed for high risk children with learning needs in the development of academic, social, physical, or conceptual skills, this manual identifies and presents, in a developmental sequence, a preschool program for disadvantaged and migrant five-year-old children. The program's fundamental goal is to prepare each disadvantaged and/or migrant…

  17. Guide to Effective Program Practices. Worker Education Program Staff Development Manual.

    ERIC Educational Resources Information Center

    Moran, Sarah

    This document is the staff development manual that was developed to train worker education facilitators involved in the Chicago Teachers' Center of Northeastern Illinois University and Amalgamated Clothing and Textile Workers Union Worker Education Program (WEP). The document begins with an overview of the WEP, which uses workers' life and…

  18. U.S. EPA (ENVIRONMENTAL PROTECTION AGENCY) WASTEWATER DISINFECTION RESEARCH PROGRAM EVOLUTION TO A DESIGN MANUAL

    EPA Science Inventory

    The paper presents the history of the EPA wastewater disinfection research program from the early 1970's until it culminated with the publication of the Process Design Manual in September 1986. The program was elevated to the highest Agency research priority in 1976 with the infu...

  19. Supervision Manual: Social Studies Program.

    ERIC Educational Resources Information Center

    Szabo, Lester John

    This manual is designed to help school personnel implement a social studies program in grades K-12 in New York State. It provides the State mandates for social studies, recommends the scope and sequence of the social studies program, and suggests a procedure for implementing social studies revisions at the local level. How to form a local social…

  20. Program Manual for Estimating Use and Related Statistics on Developed Recreation Sites

    Treesearch

    Gary L. Tyre; Gene R. Welch

    1972-01-01

    This manual includes documentation of four computer programs supporting subroutines for estimating use, visitor origin, patterns of use, and occupancy rates at developed recreation sites. The programs are written in Fortran IV and should be easily adapted to any computer arrangement have the capacity to compile this language.

  1. The History Colloquium Manual: Energizing Professional Development for History Teachers. Occasional Paper.

    ERIC Educational Resources Information Center

    National Council for History Education, Inc., Westlake, OH.

    This occasional paper describes the National Council for History Education's program of professional development for history teachers along with the principles that were used to institute the program. The manual is intended as a guide for educators to establish their own history colloquium programs. The 10 sections are: (1)…

  2. Pathways to Success; A Resource Manual for the Dissemination of Successful Educational Programs.

    ERIC Educational Resources Information Center

    Soper, Dorothy

    This manual is designed to describe and disseminate information about innovative New Jersey educational programs that have been validated by the standards and guidelines of the United States Office of Education as successful, cost effective, and exportable. Chapter 1 contains an overview of the development process for educational programs and…

  3. Training Manual for School Bus Drivers Transporting the Handicapped. [A Resource Manual for the Development and Evaluation of Special Programs for Exceptional Students, Volume IV-A].

    ERIC Educational Resources Information Center

    Florida State Dept. of Education, Tallahassee. Bureau of Education for Exceptional Students.

    One of a series designed to help Florida school districts provide special programs for exceptional children, the training packet is intended to be used in a 2-day training session for school bus drivers who transport handicapped students. The manual includes a brief introduction to five disability areas (physical impairments, visual impairments,…

  4. Structural Tailoring of Advanced Turboprops (STAT) programmer's manual

    NASA Technical Reports Server (NTRS)

    Brown, K. W.; Harvey, P. R.

    1989-01-01

    The Structural Tailoring of Advanced Turboprops (STAT) computer program was developed to perform numerical optimizations on highly swept propfan blades. This manual describes the functionality of the STAT system from a programmer's viewpoint. It provides a top-down description of module intent and interaction. The purpose of this manual is to familiarize the programmer with the STAT system should he/she wish to enhance or verify the program's function.

  5. Students' Own Bookshop: A Program To Enhance Middle Grades Reading and Leadership through Student Managed Paperback Bookshop Operation. Manual of Ideas and Procedures.

    ERIC Educational Resources Information Center

    Braught, Loran, Comp.

    This manual was developed as one outcome of a 2-year experimental project conducted in 53 school districts in Indiana (1990-92). The manual was designed to be a resource to schools interested in operating a successful "Students' Own Bookshop" program to encourage development of literacy and leadership among the students of their school.…

  6. Training Effectiveness Evaluation of Device A/F37A-T59

    DTIC Science & Technology

    1982-07-01

    selected airplane by manually setting track, crosstrack, and altitude on thE control panel. Posi ion is maintained by flying the attitude director...simulator’s other design capabilities includes full SKE airdrop simulation, radar simulation, manual or pre-programmed malfunctions, a library of...during IFS testing, this feature was not available for this study. Thus, the instructors had to manually program all mission profiles prior to each

  7. Simulated trajectories error analysis program, version 2. Volume 2: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Vogt, E. D.; Adams, G. L.; Working, M. M.; Ferguson, J. B.; Bynum, M. R.

    1971-01-01

    A series of three computer programs for the mathematical analysis of navigation and guidance of lunar and interplanetary trajectories was developed. All three programs require the integration of n-body trajectories for both interplanetary and lunar missions. The virutal mass technique is used in all three programs. The user's manual contains the information necessary to operate the programs. The input and output quantities of the programs are described. Sample cases are given and discussed.

  8. A three-dimensional, compressible, laminar boundary-layer method for general fuselages. Volume 2: User's manual

    NASA Technical Reports Server (NTRS)

    Wie, Yong-Sun

    1990-01-01

    This user's manual contains a complete description of the computer programs developed to calculate three-dimensional, compressible, laminar boundary layers for perfect gas flow on general fuselage shapes. These programs include the 3-D boundary layer program (3DBLC), the body-oriented coordinate program (BCC), and the streamline coordinate program (SCC). Subroutine description, input, output and sample case are discussed. The complete FORTRAN listings of the computer programs are given.

  9. Distress identification manual for the long-term pavement performance program (Fifth revised edition)

    DOT National Transportation Integrated Search

    2014-05-01

    Accurate, consistent, and repeatable distress evaluation surveys can be performed by using the Distress Identification Manual for the Long-Term Pavement Performance Program. Color photographs and drawings illustrate the distresses found in three basi...

  10. Method of fan sound mode structure determination computer program user's manual: Microphone location program

    NASA Technical Reports Server (NTRS)

    Pickett, G. F.; Wells, R. A.; Love, R. A.

    1977-01-01

    A computer user's manual describing the operation and the essential features of the microphone location program is presented. The Microphone Location Program determines microphone locations that ensure accurate and stable results from the equation system used to calculate modal structures. As part of the computational procedure for the Microphone Location Program, a first-order measure of the stability of the equation system was indicated by a matrix 'conditioning' number.

  11. Workplace Safety Manual

    DOT National Transportation Integrated Search

    2002-04-10

    N.C. Department of Transportation's workplace safety manual for online viewing. : The government of North Carolina feels that all employees are responsible for safety : on the job. This manual describes and sets out the operation of safety program : ...

  12. The work programme of EURADOS on internal and external dosimetry.

    PubMed

    Rühm, W; Bottollier-Depois, J F; Gilvin, P; Harrison, R; Knežević, Ž; Lopez, M A; Tanner, R; Vargas, A; Woda, C

    2018-01-01

    Since the early 1980s, the European Radiation Dosimetry Group (EURADOS) has been maintaining a network of institutions interested in the dosimetry of ionising radiation. As of 2017, this network includes more than 70 institutions (research centres, dosimetry services, university institutes, etc.), and the EURADOS database lists more than 500 scientists who contribute to the EURADOS mission, which is to promote research and technical development in dosimetry and its implementation into practice, and to contribute to harmonisation of dosimetry in Europe and its conformance with international practices. The EURADOS working programme is organised into eight working groups dealing with environmental, computational, internal, and retrospective dosimetry; dosimetry in medical imaging; dosimetry in radiotherapy; dosimetry in high-energy radiation fields; and harmonisation of individual monitoring. Results are published as freely available EURADOS reports and in the peer-reviewed scientific literature. Moreover, EURADOS organises winter schools and training courses on various aspects relevant for radiation dosimetry, and formulates the strategic research needs in dosimetry important for Europe. This paper gives an overview on the most important EURADOS activities. More details can be found at www.eurados.org .

  13. The School Personnel Management System. Manual 1--Tools. Manual 2--Models. Manual 3--Results.

    ERIC Educational Resources Information Center

    National School Boards Association, Washington, DC.

    The School Personnel Management System offers a correlated set of job descriptions, evaluative instruments, policies, tools, forms, and publications intended to aid local school officials in enhancing their personnel management programs. The materials are contained in two looseleaf binders entitled "Manual 1--Tools," and "Manual…

  14. Aircraft noise prediction program propeller analysis system IBM-PC version user's manual version 2.0

    NASA Technical Reports Server (NTRS)

    Nolan, Sandra K.

    1988-01-01

    The IBM-PC version of the Aircraft Noise Prediction Program (ANOPP) Propeller Analysis System (PAS) is a set of computational programs for predicting the aerodynamics, performance, and noise of propellers. The ANOPP-PAS is a subset of a larger version of ANOPP which can be executed on CDC or VAX computers. This manual provides a description of the IBM-PC version of the ANOPP-PAS and its prediction capabilities, and instructions on how to use the system on an IBM-XT or IBM-AT personal computer. Sections within the manual document installation, system design, ANOPP-PAS usage, data entry preprocessors, and ANOPP-PAS functional modules and procedures. Appendices to the manual include a glossary of ANOPP terms and information on error diagnostics and recovery techniques.

  15. Aircraft operations management manual

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  16. Plotting program for aerodynamic lifting surface theory. [user manual for FORTRAN computer program

    NASA Technical Reports Server (NTRS)

    Medan, R. T.; Ray, K. S.

    1973-01-01

    A description of and users manual for a USA FORTRAN IV computer program which plots the planform and control points of a wing are presented. The program also plots some of the configuration data such as the aspect ratio. The planform data is stored on a disc file which is created by a geometry program. This program, the geometry program, and several other programs are used together in the analysis of lifting, thin wings in steady, subsonic flow according to a kernel function lifting surface theory.

  17. Shared Dosimetry Error in Epidemiological Dose-Response Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stram, Daniel O.; Preston, Dale L.; Sokolnikov, Mikhail

    2015-03-23

    Radiation dose reconstruction systems for large-scale epidemiological studies are sophisticated both in providing estimates of dose and in representing dosimetry uncertainty. For example, a computer program was used by the Hanford Thyroid Disease Study to provide 100 realizations of possible dose to study participants. The variation in realizations reflected the range of possible dose for each cohort member consistent with the data on dose determinates in the cohort. Another example is the Mayak Worker Dosimetry System 2013 which estimates both external and internal exposures and provides multiple realizations of "possible" dose history to workers given dose determinants. This paper takesmore » up the problem of dealing with complex dosimetry systems that provide multiple realizations of dose in an epidemiologic analysis. In this paper we derive expected scores and the information matrix for a model used widely in radiation epidemiology, namely the linear excess relative risk (ERR) model that allows for a linear dose response (risk in relation to radiation) and distinguishes between modifiers of background rates and of the excess risk due to exposure. We show that treating the mean dose for each individual (calculated by averaging over the realizations) as if it was true dose (ignoring both shared and unshared dosimetry errors) gives asymptotically unbiased estimates (i.e. the score has expectation zero) and valid tests of the null hypothesis that the ERR slope β is zero. Although the score is unbiased the information matrix (and hence the standard errors of the estimate of β) is biased for β≠0 when ignoring errors in dose estimates, and we show how to adjust the information matrix to remove this bias, using the multiple realizations of dose. Use of these methods for several studies, including the Mayak Worker Cohort and the U.S. Atomic Veterans Study, is discussed.« less

  18. Automated Literature Searches for Longitudinal Tracking of Cancer Research Training Program Graduates.

    PubMed

    Padilla, Luz A; Desmond, Renee A; Brooks, C Michael; Waterbor, John W

    2018-06-01

    A key outcome measure of cancer research training programs is the number of cancer-related peer-reviewed publications after training. Because program graduates do not routinely report their publications, staff must periodically conduct electronic literature searches on each graduate. The purpose of this study is to compare findings of an innovative computer-based automated search program versus repeated manual literature searches to identify post-training peer-reviewed publications. In late 2014, manual searches for publications by former R25 students identified 232 cancer-related articles published by 112 of 543 program graduates. In 2016, a research assistant was instructed in performing Scopus literature searches for comparison with individual PubMed searches on our 543 program graduates. Through 2014, Scopus found 304 cancer publications, 220 of that had been retrieved manually plus an additional 84 papers. However, Scopus missed 12 publications found manually. Together, both methods found 316 publications. The automated method found 96.2 % of the 316 publications while individual searches found only 73.4 %. An automated search method such as using the Scopus database is a key tool for conducting comprehensive literature searches, but it must be supplemented with periodic manual searches to find the initial publications of program graduates. A time-saving feature of Scopus is the periodic automatic alerts of new publications. Although a training period is needed and initial costs can be high, an automated search method is worthwhile due to its high sensitivity and efficiency in the long term.

  19. Finding Federal Money for Children's Services: Financing Services for Children through Title XX and Other Programs. Manual 1.

    ERIC Educational Resources Information Center

    Copeland, William C.

    This is the first manual of a 4-part series on how to find, obtain, contract for and manage Federal money for children's services. The first manual concentrates on ways to locate funds for new and existing programs. Emphasis is on Title XX of the Social Security Act, but attention is given also to alternative sources where Title XX funds are not…

  20. On Paper or Hypermedia? The Effect of Procedural Information in Digital Video Format in the Learning of a Music Score Editor Program by Novice Users.

    ERIC Educational Resources Information Center

    Gimenez, Jesus Tejada; Saenz de Jubera, Magdalena

    This study, by means of an experimental design, examines whether the use of an electronic manual is more effective and efficient than a print manual for the training of novice users with a music score editor program. Differences in access to the two types of manuals were looked for, and information on users' perceptions regarding the materials…

  1. Classification of Living Things. A Teacher's Manual for General Level Program Development. Grades 7 and 8. Science and Society Teaching Units. Informal Series/55.

    ERIC Educational Resources Information Center

    Roberts, Douglas A.; And Others

    This manual is one of a series designed to assist junior high school teachers in developing general level or non-academic science programs which focus on the relationship between science and society. Although designed primarily for grades 7 and 8, the content is also suitable for students in grade 6. The major portion of the manual consists of six…

  2. Operators manual for the magnetograph program (section 2)

    NASA Technical Reports Server (NTRS)

    November, L.; Title, A. M.

    1974-01-01

    This manual for use of the magnetograph program describes: (1) black box use of the programs; (2) the magtape data formats used; (3) the adjustable control parameters in the program; and (4) the algorithms. With no adjustments on the control parameters this program may be used purely as a black box. For optimal use, however, the control parameters may be varied. The magtape data formats are of use in adopting other programs to look at raw data or final magnetograph data.

  3. Lunar observations verifier editor programmer's manual, revision 1

    NASA Technical Reports Server (NTRS)

    Barnett, E. L.

    1974-01-01

    The prime purpose of the programmer's manual is to aid the programmer in understanding the programming aspects of the program. A description of the input, the printout, the deck setup, and tape configuration may be obtained from the LOVE user's guide.

  4. Flight dynamics analysis and simulation of heavy lift airships. Volume 5: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Ringland, R. F.; Tischler, M. B.; Jex, H. R.; Emmen, R. D.; Ashkenas, I. L.

    1982-01-01

    The Programmer's Manual contains explanations of the logic embodied in the various program modules, a dictionary of program variables, a subroutine listing, subroutine/common block/cross reference listing, and a calling/called subroutine cross reference listing.

  5. Records Management Manual.

    ERIC Educational Resources Information Center

    Alaska State Dept. of Education, Juneau. State Archives and Records Management.

    This manual, prepared primarily for state government agencies, describes the organization and management of Alaska government records. Information is presented in nine topic areas: (1) Alaska's Archives and Records Management Program, which describes the program, its mission, services available, and employee responsibilities; (2) Records in…

  6. USERS MANUAL FOR HYDROLOGICAL SIMULATION PROGRAM - FORTRAN (HSPF)

    EPA Science Inventory

    The Hydrological Simulation Program--Fortran (HSPF) is a set of computer codes that can simulate the hydrologic, and associated water quality, processes on pervious and impervious land surfaces and in streams and well-mixed impoundments. The manual discusses the modular structure...

  7. Teamwork for Healthy Campuses. NYS College Alcohol and Other Drug Programs.

    ERIC Educational Resources Information Center

    Harding, Frances M.

    This manual offers information on developing, implementing, and maintaining college alcohol and other drug programs at New York institutions of higher education. The document notes that alcohol is the drug of choice for college students and that therefore alcohol-related issues and programs are the primary focus of the manual. Part 1 of the manual…

  8. Outer Space...Calling All Readers. 1991 Summer Reading Program Manual.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Cultural Resources, Raleigh. Div. of State Library.

    This manual provides guidelines and materials for librarians planning a summer reading program for children in North Carolina on the theme of outer space. An evaluation form to be returned to the State Library of North Carolina at the end of the summer is included. The introduction includes discussions of summer reading materials and programs;…

  9. ART TEACHING GUIDE--HAWAII, KINDERGARTEN THROUGH GRADE 12.

    ERIC Educational Resources Information Center

    VAN PIERA, LURENE H.; AND OTHERS

    ART IS AN IMPORTANT PART OF A BALANCED PROGRAM FOR THE TOTAL CULTURAL DEVELOPMENT OF EVERY STUDENT. THIS MANUAL SUGGESTS RESOURCES FOR DEVELOPING AN EFFECTIVE ART PROGRAM. AN ART PROGRAM SHOULD BE BASED ON THE NEEDS, INTERESTS, AND EXPERIENCES OF THE PUPIL, THEREFORE, THIS GUIDE IS ORGANIZED BY ART AREAS RATHER THAN BY GRADE LEVEL. THIS MANUAL CAN…

  10. Highway Safety Program Manual: Volume 16: Debris Hazard Control and Cleanup.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 16 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) concentrates on debris hazard control and cleanup. The purpose and objectives of such a program are outlined. Federal authority in the area of highway safety and policies regarding a debris control…

  11. A Part, Not Apart: A Systematic Approach to Integrated Recreation and Leisure for Developmentally Disabled Adults.

    ERIC Educational Resources Information Center

    Congdon, David M.; And Others

    This program manual was developed by the Grant-Blackford Development Center in order to help other professionals and organizations working with developmentally disabled persons to improve their recreation and leisure programs. The manual's philosophy is to structure recreation programs for fun, not just for skill teaching: stressing abilities, not…

  12. Urban Tree Risk Management:A Community Guide to Program Design and Implementation

    Treesearch

    Jill Pokorny; Joseph O' Brien; Richard Hauer; Gary Johnson; Jana Albers; Peter Bedker; Manfred Mielke

    2003-01-01

    Urban Tree Risk Management: A Community Guide to Program Design and Implementation is a fully illustrated, easy to read training manual written for community leaders, administrators, city foresters, parks and public works staff, and private tree care practitioners. The manual is designed to assist communities design, adopt and implement tree risk management programs,...

  13. CDPOP Users Manual

    Treesearch

    E. L. Landguth; B. K. Hand; J. M. Glassy; S. A. Cushman; M. Jacobi; T. J. Julian

    2011-01-01

    The goal of this user manual is to explain the technical aspects of the current release of the CDPOP program. CDPOP v1.0 is a major extension of the CDPOP program (Landguth and Cushman 2010). CDPOP is an individual-based program that simulates the influences of landscape structure on emergence of spatial patterns in population genetic data as functions of individual-...

  14. 42 CFR 137.5 - Effect of these regulations on Federal program guidelines, manual, or policy directives.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Effect of these regulations on Federal program... SELF-GOVERNANCE General Provisions § 137.5 Effect of these regulations on Federal program guidelines... funding agreement, the Self-Governance Tribe shall not be subject to any agency circular, policy, manual...

  15. 42 CFR 137.5 - Effect of these regulations on Federal program guidelines, manual, or policy directives.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Effect of these regulations on Federal program... SELF-GOVERNANCE General Provisions § 137.5 Effect of these regulations on Federal program guidelines... funding agreement, the Self-Governance Tribe shall not be subject to any agency circular, policy, manual...

  16. 42 CFR 137.5 - Effect of these regulations on Federal program guidelines, manual, or policy directives.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Effect of these regulations on Federal program... SELF-GOVERNANCE General Provisions § 137.5 Effect of these regulations on Federal program guidelines... funding agreement, the Self-Governance Tribe shall not be subject to any agency circular, policy, manual...

  17. 42 CFR 137.5 - Effect of these regulations on Federal program guidelines, manual, or policy directives.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Effect of these regulations on Federal program... SELF-GOVERNANCE General Provisions § 137.5 Effect of these regulations on Federal program guidelines... funding agreement, the Self-Governance Tribe shall not be subject to any agency circular, policy, manual...

  18. 42 CFR 137.5 - Effect of these regulations on Federal program guidelines, manual, or policy directives.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Effect of these regulations on Federal program... SELF-GOVERNANCE General Provisions § 137.5 Effect of these regulations on Federal program guidelines... funding agreement, the Self-Governance Tribe shall not be subject to any agency circular, policy, manual...

  19. Readers of the Round Table: The 1998 Joint Kentucky - Arizona Reading Program.

    ERIC Educational Resources Information Center

    Kentucky State Dept. for Libraries and Archives, Frankfort.

    Intended to encourage children of all ages to read over the summer, this manual presents library-based programs, crafts, displays, and events with a medieval theme. The chapters of the manual are: (1) Introductory Materials; (2) Goals, Objectives and Evaluation; (3) Getting Started; (4) Common Program Structures; (5) Planning Timeline; (6)…

  20. 76 FR 39033 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG (RRD) BR700-710 Series Turbofan...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-05

    ... limitation section (ALS) of their approved maintenance program (Time Limits Manual (TLM), chapters 05-00-01... airplanes used for pilot training. Revise their ALS of their approved maintenance program (TLM chapters 05... limitations section (ALS) of the operators approved maintenance program (reference the Time Limits Manual (TLM...

  1. Meyer Children's Rehabilitation Institute Teaching Program for Young Children. [Prescriptive Teaching Program for Multiply Handicapped Nursery School Children].

    ERIC Educational Resources Information Center

    LaCrosse, Edward; And Others

    The prescriptive teaching program for multiply handicapped nursery school children is presented in three manuals: prescriptive teaching, integration of prescriptions into classroom activities; and equipment and materials. Given in the prescriptive teaching manual are directions for assessing a child's strengths and weaknesses in functioning on a…

  2. Mission Analysis Program for Solar Electric Propulsion (MAPSEP). Volume 3: Program manual for earth orbital MAPSEP

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A revised user's manual for the computer program MAPSEP is presented. Major changes from the interplanetary version of MAPSEP are summarized. The changes are intended to provide a basic capability to analyze anticipated solar electric missions, and a foundation for future more complex, modifications. For Vol. III, N75-16589.

  3. Nebraska Work Based Learning Manual. Planning and Implementation Guides for Educators, Employers, Policymakers, and Parents.

    ERIC Educational Resources Information Center

    Nebraska State Dept. of Education, Lincoln.

    This manual contains a series of 10 detailed guides for school practitioners who are beginning to create work-based learning programs at their schools. Work-Based Learning Overview defines the different elements of work-based learning and describes the roles of program participants. Program Planning Guide offers suggestions about how to plan…

  4. Proceedings of a Meeting on Traceability for Ionizing Radiation Measurements

    NASA Astrophysics Data System (ADS)

    Heaton, H. T., II

    1982-02-01

    General concepts for traceability were presented from several perspectives. The national standards for radiation dosimetry, radioactivity measurements, and neutron measurements were described. Specific programs for achieving traceability to the national standards for radiation measurements in medical, occupational, and environmental applications were summarized.

  5. Incorporating Human Dosimetry and Exposure into High-Throughput In Vitro Toxicity Screening

    EPA Science Inventory

    Many chemicals in commerce today have undergone limited or no safety testing. To reduce the number of untested chemicals and prioritize limited testing resources, several governmental programs are using high-throughput in vitro screens for assessing chemical effects across multip...

  6. A technique for pediatric total skin electron irradiation.

    PubMed

    Bao, Qinan; Hrycushko, Brian A; Dugas, Joseph P; Hager, Frederick H; Solberg, Timothy D

    2012-03-20

    Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA) methods for implementing a modified Stanford technique using a rotating harness system to position sedated pediatric patients treated with electrons to the total skin. Commissioning of pediatric TSEI consisted of absolute calibration, measurement of dosimetric parameters, and subsequent verification in a pediatric patient sized cylindrical phantom using radiographic film and optically stimulated luminance (OSL) dosimeters. The depth of dose penetration under TSEI treatment condition was evaluated using radiographic film sandwiched in the phantom and demonstrated a 2 cm penetration depth with the maximum dose located at the phantom surface. Dosimetry measurements on the cylindrical phantom and in-vivo measurements from the patients suggested that, the factor relating the skin and calibration point doses (i.e., the B-factor) was larger for the pediatric TSEI treatments as compared to adult TSEI treatments. Custom made equipment, including a rotating plate and harness, was fabricated and added to a standard total body irradiation stand and tested to facilitate patient setup under sedated condition. A pediatric TSEI QA program, consisting of daily output, energy, flatness, and symmetry measurements as well as in-vivo dosimetry verification for the first cycle was developed. With a long interval between pediatric TSEI cases, absolute dosimetry was also repeated as part of the QA program. In-vivo dosimetry for the first two infants showed that a dose of ± 10% of the prescription dose can be achieved over the entire patient body. Though pediatric leukemia cutis and the subsequent need for TSEI are rare, the ability to commission the technique on a modified TBI stand is appealing for clinical implementation and has been successfully used for the treatment of two pediatric patients at our institution.

  7. A technique for pediatric total skin electron irradiation

    PubMed Central

    2012-01-01

    Background Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA) methods for implementing a modified Stanford technique using a rotating harness system to position sedated pediatric patients treated with electrons to the total skin. Methods and Results Commissioning of pediatric TSEI consisted of absolute calibration, measurement of dosimetric parameters, and subsequent verification in a pediatric patient sized cylindrical phantom using radiographic film and optically stimulated luminance (OSL) dosimeters. The depth of dose penetration under TSEI treatment condition was evaluated using radiographic film sandwiched in the phantom and demonstrated a 2 cm penetration depth with the maximum dose located at the phantom surface. Dosimetry measurements on the cylindrical phantom and in-vivo measurements from the patients suggested that, the factor relating the skin and calibration point doses (i.e., the B-factor) was larger for the pediatric TSEI treatments as compared to adult TSEI treatments. Custom made equipment, including a rotating plate and harness, was fabricated and added to a standard total body irradiation stand and tested to facilitate patient setup under sedated condition. A pediatric TSEI QA program, consisting of daily output, energy, flatness, and symmetry measurements as well as in-vivo dosimetry verification for the first cycle was developed. With a long interval between pediatric TSEI cases, absolute dosimetry was also repeated as part of the QA program. In-vivo dosimetry for the first two infants showed that a dose of ± 10% of the prescription dose can be achieved over the entire patient body. Conclusion Though pediatric leukemia cutis and the subsequent need for TSEI are rare, the ability to commission the technique on a modified TBI stand is appealing for clinical implementation and has been successfully used for the treatment of two pediatric patients at our institution. PMID:22433063

  8. Chemical Dependency and Violence: Working with Dually Affected Families. A Cross-Training Program Manual for Counselors and Advocates.

    ERIC Educational Resources Information Center

    Wright, Janet M.

    This manual is designed as a cross-training program guide for counselors working in the fields of woman abuse and chemical dependency. (A cross-training program is a system for one (or more) agency personnel to train each other in their respective areas of expertise.) Chapter 1 discusses the rationale and goals of a cross-training program; issues…

  9. Becoming Sex Fair. The Tredyffrin/Easttown Program. A Comprehensive Model for Public School Districts. Stage Two Manual: Planning the In-Service Program.

    ERIC Educational Resources Information Center

    Calabrese, Marylyn E.; And Others

    This manual, one of four related documents, is the second stage in a sex fairness program implemented in the Tredyffrin/Easttown School District (Pennsylvania). It is designed to help a school district plan an inservice program on sex-fair education for teachers, administrators, and parents. The first section describes the two steps in the…

  10. Development of weight/sizing design synthesis computer program. Volume 3: User Manual

    NASA Technical Reports Server (NTRS)

    Garrison, J. M.

    1973-01-01

    The user manual for the weight/sizing design synthesis program is presented. The program is applied to an analysis of the basic weight relationships for the space shuttle which contribute significant portions of the inert weight. The relationships measure the parameters of load, geometry, material, and environment. A verbal description of the processes simulated, data input procedures, output data, and values present in the program is included.

  11. Computer Program for Calculation of Complex Chemical Equilibrium Compositions and Applications II. Users Manual and Program Description. 2; Users Manual and Program Description

    NASA Technical Reports Server (NTRS)

    McBride, Bonnie J.; Gordon, Sanford

    1996-01-01

    This users manual is the second part of a two-part report describing the NASA Lewis CEA (Chemical Equilibrium with Applications) program. The program obtains chemical equilibrium compositions of complex mixtures with applications to several types of problems. The topics presented in this manual are: (1) details for preparing input data sets; (2) a description of output tables for various types of problems; (3) the overall modular organization of the program with information on how to make modifications; (4) a description of the function of each subroutine; (5) error messages and their significance; and (6) a number of examples that illustrate various types of problems handled by CEA and that cover many of the options available in both input and output. Seven appendixes give information on the thermodynamic and thermal transport data used in CEA; some information on common variables used in or generated by the equilibrium module; and output tables for 14 example problems. The CEA program was written in ANSI standard FORTRAN 77. CEA should work on any system with sufficient storage. There are about 6300 lines in the source code, which uses about 225 kilobytes of memory. The compiled program takes about 975 kilobytes.

  12. A TWO-YEAR POST-HIGH SCHOOL DISTRIBUTIVE EDUCATION PROGRAM IN THE WHOLESALING FIELD, REPORT OF THE OHIO WHOLESALE MANAGEMENT DEVELOPMENT PROGRAM. MANUAL 2, CURRICULUM FOR A PROGRAM.

    ERIC Educational Resources Information Center

    LOGAN, WILLIAM B.; AND OTHERS

    THE PURPOSE OF THIS MANUAL IS TO SERVE AS A CURRICULUM GUIDE FOR PLANNING COURSES FOR A 2-YEAR POST-HIGH SCHOOL DISTRIBUTIVE EDUCATION PROGRAM IN THE FIELD OF WHOLESALING. THE CONTENT WAS DEVELOPED BY A RESEARCH GROUP AND INCORPORATED SUGGESTIONS THE INSTRUCTORS IN AN EXPERIMENTAL PROGRAM CONDUCTED ON THE CAMPUS OF THE OHIO STATE UNIVERSITY FOR 4…

  13. A Training Manual for Nuclear Medicine Technologists.

    ERIC Educational Resources Information Center

    Simmons, Guy H.; Alexander, George W.

    This manual was prepared for a training program in Nuclear Medicine Technology at the University of Cincinnati. Instructional materials for students enrolled in these courses in the training program include: Nuclear Physics and Instrumentation, Radionuclide Measurements, Radiation Protection, and Tracer Methodology and Radiopharmaceuticals. (CS)

  14. Design and evaluation of brushless electrical generators

    NASA Technical Reports Server (NTRS)

    Collins, F. A.; Ellis, J. N.

    1970-01-01

    Ten design manuals assembled and nine computer programs are developed for evaluation of proposed designs of brushless rotating electrical generators. Design manual package provides all information required for generator design, and computer programs permit calculation of performance of specific designs including effects of materials.

  15. Long-term pavement performance program manual for falling weight deflectometer measurements

    DOT National Transportation Integrated Search

    2006-12-01

    This manual is intended for use in collection of Falling Weight Deflectometer (FWD) data for the Long-Term Pavement Performance (LTPP) program. As such, it contains background information on FWD equipment and the general role of FWD testing within LT...

  16. TADS Needs Assessment Procedures Manual, Summer 1980.

    ERIC Educational Resources Information Center

    Black, Talbot; And Others

    The TADS (Technical Assistance Development System) Needs Assessment Manual is designed to guide the comprehensive review of Handicapped Children's Early Education Program (HCEEP) demonstration projects in identifying technical assistance needs. An introduction reviews the TADS technical assistance model which includes program planning, needs…

  17. Radiology Aide. Instructor Key [and] Student Manual.

    ERIC Educational Resources Information Center

    Hartwein, Jon; Dunham, John

    This manual can be used independently by students in secondary health occupations programs or by persons receiving on-the-job training in a radiology department. The manual includes an instructor's key that provides answers to the activity sheets and unit evaluations. The manual consists of the following five units: (1) orientation to radiology;…

  18. Assessment of the impact of the change from manual to automated coding on mortality statistics in Australia.

    PubMed

    McKenzie, Kirsten; Walker, Sue; Tong, Shilu

    It remains unclear whether the change from a manual to an automated coding system (ACS) for deaths has significantly affected the consistency of Australian mortality data. The underlying causes of 34,000 deaths registered in 1997 in Australia were dual coded, in ICD-9 manually, and by using an automated computer coding program. The diseases most affected by the change from manual to ACS were senile/presenile dementia, and pneumonia. The most common disease to which a manually assigned underlying cause of senile dementia was coded with ACS was unspecified psychoses (37.2%). Only 12.5% of codes assigned by ACS as senile dementia were coded the same by manual coders. This study indicates some important differences in mortality rates when comparing mortality data that have been coded manually with those coded using an automated computer coding program. These differences may be related to both the different interpretation of ICD coding rules between manual and automated coding, and different co-morbidities or co-existing conditions among demographic groups.

  19. Computer Program User’s Manual for FIREFINDER Digital Topographic Data Verification Library Dubbing System. Volume II. Dubbing.

    DTIC Science & Technology

    1982-01-29

    N - Nw .VA COMPUTER PROGRAM USER’S MANUAL FOR . 0FIREFINDER DIGITAL TOPOGRAPHIC DATA VERIFICATION LIBRARY DUBBING SYSTEM VOLUME II DUBBING 29 JANUARY...Digital Topographic Data Verification Library Dubbing System, Volume II, Dubbing 6. PERFORMING ORG. REPORT NUMER 7. AUTHOR(q) S. CONTRACT OR GRANT...Software Library FIREFINDER Dubbing 20. ABSTRACT (Continue an revWee *Ide II necessary end identify by leek mauber) PThis manual describes the computer

  20. General Safety Manual for Vocational-Technical Education and Industrial Arts Programs. Bulletin No. 1674.

    ERIC Educational Resources Information Center

    Dennis, Bill; Poston, David

    This manual is designed to offer suggestions for teaching safety in Louisiana industrial arts and vocational education programs. The suggestions and information presented are intended for use in an ongoing safety program, not a short unit presented at the beginning of the school year. Following an introduction in unit 1, the material has been…

  1. Photomask and pattern programming manual

    NASA Technical Reports Server (NTRS)

    Kirschman, R. K.

    1978-01-01

    A user's manual for a set of computer programs written in FORTRAN for the layout and generation of photomasks is presented. A limited amount of related information on photomasks, their design, and use is included. Input to the programs includes data describing the photomask design. Possible outputs include plots of the layout and a magnetic tape for controlling generation of the photomask by a pattern generator.

  2. Comprehensive Early Stimulation Program for Infants. Instruction Manual [and] Early Interventionist's Workbook [and] Parent/Caregiver Workbook. William Beaumont Hospital Speech and Language Pathology Series.

    ERIC Educational Resources Information Center

    Santana, Altagracia A.; Bottino, Patti M.

    This early intervention kit includes a Comprehensive Early Stimulation Program for Infants (CESPI) instruction manual, an early interventionist workbook, and ten parent/caregiver workbooks. The CESPI early intervention program is designed to provide therapists, teachers, other health professionals, and parents with a common-sense, practical guide…

  3. DFLOW USER'S MANUAL

    EPA Science Inventory

    DFLOW is a computer program for estimating design stream flows for use in water quality studies. The manual describes the use of the program on both the EPA's IBM mainframe system and on a personal computer (PC). The mainframe version of DFLOW can extract a river's daily flow rec...

  4. Electrostatic Precipitator (ESP) TRAINING MANUAL

    EPA Science Inventory

    The manual assists engineers in using a computer program, the ESPVI 4.0W, that models all elements of an electrostatic precipitator (ESP). The program is a product of the Electric Power Research Institute and runs in the Windows environment. Once an ESP is accurately modeled, the...

  5. COMPUTERIZED FGD BYPRODUCT PRODUCTION AND MARKETING SYSTEM: USERS MANUAL

    EPA Science Inventory

    The users manual describes a computerized system--consisting of a number of integrated programs, models, and data bases--that has been developed to compare the costs of power plant strategies designed to meet clean air regulations. It describes the data bases, programs, and proce...

  6. Project Evolve User-Adopter Manual.

    ERIC Educational Resources Information Center

    Joiner, Lee M.

    An adult basic education (ABE) program for mentally retarded young adults between the ages of 14 and 26 years, Project Evolve can provide education agencies for educationally handicapped children with detailed information concerning an innovative program. The manual format was developed through interviews with professional educators concerning the…

  7. HYDROLOGICAL SIMULATION PROGRAM-FORTRAN (HSPF): USERS MANUAL FOR RELEASE 8.0

    EPA Science Inventory

    The Hydrological Simulation Program--FORTRAN (HSPF) is a set of computer codes that can simulate the hydrologic, and associated water quality, processes on pervious and impervious land surfaces and in streams and well mixed impoundments. The manual discusses the modular structure...

  8. Update of FDOT state park & ride lot program planning manual chapters 3, 4, and 6

    DOT National Transportation Integrated Search

    2001-04-01

    Portions of the Florida Department of Transportation (FDOT) State Park & Ride Lot Program Planning Manual, first published in 1989 and revised in 1996, were updated. The scope included examination, testing, and updating, as necessary, the planning fo...

  9. Compensators: An alternative IMRT delivery technique

    PubMed Central

    Chang, Sha X.; Cullip, Timothy J.; Deschesne, Katharin M.; Miller, Elizabeth P.; Rosenman, Julian G.

    2004-01-01

    Seven years of experience in compensator intensity‐modulated radiotherapy (IMRT) clinical implementation are presented. An inverse planning dose optimization algorithm was used to generate intensity modulation maps, which were delivered via either the compensator or segmental multileaf collimator (MLC) IMRT techniques. The in‐house developed compensator‐IMRT technique is presented with the focus on several design issues. The dosimetry of the delivery techniques was analyzed for several clinical cases. The treatment time for both delivery techniques on Siemens accelerators was retrospectively analyzed based on the electronic treatment record in LANTIS for 95 patients. We found that the compensator technique consistently took noticeably less time for treatment of equal numbers of fields compared to the segmental technique. The typical time needed to fabricate a compensator was 13 min, 3 min of which was manual processing. More than 80% of the approximately 700 compensators evaluated had a maximum deviation of less than 5% from the calculation in intensity profile. Seventy‐two percent of the patient treatment dosimetry measurements for 340 patients have an error of no more than 5%. The pros and cons of different IMRT compensator materials are also discussed. Our experience shows that the compensator‐IMRT technique offers robustness, excellent intensity modulation resolution, high treatment delivery efficiency, simple fabrication and quality assurance (QA) procedures, and the flexibility to be used in any teletherapy unit. PACS numbers: 87.53Mr, 87.53Tf PMID:15753937

  10. Space shuttle solid rocket booster recovery system definition. Volume 3: SRB water impact loads computer program, user's manual

    NASA Technical Reports Server (NTRS)

    1973-01-01

    This user's manual describes the FORTRAN IV computer program developed to compute the total vertical load, normal concentrated pressure loads, and the center of pressure of typical SRB water impact slapdown pressure distributions specified in the baseline configuration. The program prepares the concentrated pressure load information in punched card format suitable for input to the STAGS computer program. In addition, the program prepares for STAGS input the inertia reacting loads to the slapdown pressure distributions.

  11. Method of fan sound mode structure determination computer program user's manual: Modal calculation program

    NASA Technical Reports Server (NTRS)

    Pickett, G. F.; Wells, R. A.; Love, R. A.

    1977-01-01

    A computer user's manual describing the operation and the essential features of the Modal Calculation Program is presented. The modal Calculation Program calculates the amplitude and phase of modal structures by means of acoustic pressure measurements obtained from microphones placed at selected locations within the fan inlet duct. In addition, the Modal Calculation Program also calculates the first-order errors in the modal coefficients that are due to tolerances in microphone location coordinates and inaccuracies in the acoustic pressure measurements.

  12. IMPMOT user's manual. [written in FORTRAN 4

    NASA Technical Reports Server (NTRS)

    Stewart, D. J.; Bishop, M. J.

    1974-01-01

    This user's manual describes the input and output variables as well as the job control language necessary to utilize the IMP-H apogee motor firing program, IMPMOT. The IMPMOT program can be executed as either a stand-alone program or as a member of the flight dynamics system. This program is used to determine the time and attitude at which to fire the IMP-H apogee boost motor. The IMPMOT program is written in FORTRAN 4 for use on the IBM 360 series computer.

  13. Manualized treatment programs for FSD: research challenges and recommendations.

    PubMed

    Hucker, Alice; McCabe, Marita P

    2012-02-01

    The use of manualized treatment programs offers a useful research framework for assessing psychotherapeutic interventions for female sexual dysfunctions (FSDs), but it does not address all issues related to methodological rigor and replication, and raises new research issues in need of discussion. The goals of this manuscript are to review the literature on treatment trials utilizing manualized psychotherapy treatments for FSD and to explore the benefits and research issues associated with the flexible use of treatment manuals. The method used was the review of the relevant literature. While the use of manualized treatments for FSDs can address certain methodological issues inherent in psychotherapy research, flexibility in manual administration is necessary in order to allow tailoring for individual needs that can be beneficial to both the participant and the research. The flexible use of manuals, as opposed to strict manual adherence, may also be more relevant for clinical utility. In order to administer manualized treatments for FSDs with appropriate flexibility, while also maximizing internal validity and replicability, the authors recommend that predetermined decision rules be utilized to guide individual tailoring, that potential gaps in the manual be identified and addressed, and that differing levels of motivation and readiness for treatment be taken into consideration in the treatment protocol. © 2011 International Society for Sexual Medicine.

  14. Manualization of Occupational Therapy Interventions: Illustrations from the Pressure Ulcer Prevention Research Program

    PubMed Central

    Blanche, Erna Imperatore; Fogelberg, Donald; Diaz, Jesus; Carlson, Mike; Clark, Florence

    2011-01-01

    The manualization of a complex occupational therapy intervention is a crucial step in ensuring treatment fidelity for both clinical application and research purposes. Towards this latter end, intervention manuals are essential for assuring trustworthiness and replicability of randomized controlled trials (RCT’s) that aim to provide evidence of the effectiveness of occupational therapy. In this paper, literature on the process of intervention manualization is reviewed. The prescribed steps are then illustrated through our experience in implementing the University of Southern California/Rancho Los Amigos National Rehabilitation Center’s collaborative Pressure Ulcer Prevention Project (PUPP). In this research program, qualitative research provided the initial foundation for manualization of a multifaceted occupational therapy intervention designed to reduce incidence of medically serious pressure ulcers in people with SCI. PMID:22214116

  15. A Reading Skills Development Program for Adult Non-Readers. Featuring: Supplementary Graphics and Sound (Voice Tutorials). Volumes 1 and 2. The TRS-80 Computer Assisted Instruction Series for Adult Basic Education Students.

    ERIC Educational Resources Information Center

    San Antonio State Hospital, TX. Office of Education Services.

    This instructional manual consists of materials for use in implementing a computer-assisted instructional program in reading skills development for adult nonreaders. Discussed first are the project during which this instructional program and manual were developed and the goals of the computer-assisted beginning reading program, a major feature of…

  16. Laboratory Services Guide

    DTIC Science & Technology

    1994-10-01

    dosimetry services using thermoluminescent dosimeters ( TLDs ) to meet 10 CFR 19, 20, 30-36, 40 and 70; to proNide dosimetry service for environmental...USAF Personnel Dosimetry Branch. Once it is determined that area or external dosimetry is necessary, request the number of TLDs required by FAX or letter... dosimetry , Request TLDs 2 - 4 weeks in advance and always designate a control badge. The Radiation Dosimetry Branch thanks you in advance for doing everything

  17. WE-D-204-04: Learning the Ropes: Clinical Immersion in the First Month of Residency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dieterich, S.

    Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiationmore » oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.« less

  18. WE-D-204-00: Session in Memory of Franca Kuchnir: Excellence in Medical Physics Residency Education

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiationmore » oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.« less

  19. WE-D-204-03: CAMPEP Residencies in a Canadian Context: Comprehensive Cancer Centers and Integrated Learning Environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, W.

    Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiationmore » oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.« less

  20. WE-D-204-02: Errors and Process Improvements in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fontenla, D.

    2016-06-15

    Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiationmore » oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.« less

  1. WE-D-204-01: Site-Specific Clinical Rotation: Into the Minds of the Radiation Oncologists

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendrickson, K.

    2016-06-15

    Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiationmore » oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.« less

  2. Head Start Social Services Training Manual for Coordinators and Staff.

    ERIC Educational Resources Information Center

    Administration for Children, Youth, and Families (DHHS), Washington, DC. Head Start Bureau.

    This training manual is designed for use by local Head Start programs in training current and new entry-level staff to deliver comprehensive social services to Head Start families. The introductory section of the manual provides an overview of Head Start, describes its social service component, and explains the organization of the manual. The…

  3. Coordinated Home Care Training Manual.

    ERIC Educational Resources Information Center

    Michigan Univ., Ann Arbor. Home Care Training Center.

    This manual is intended as a source of information and assistance in the planning, organization, implementation, and evaluation of home care programs. There are ten major sections: (1) Introduction (review of the history of home care and definition of pertinent terms), (2) Program Planning, (3) Organizational Structure, (4) Coordination and…

  4. Marketing Manual: Workplace Literacy.

    ERIC Educational Resources Information Center

    Fanshawe Coll., Strathroy (Ontario).

    This manual applies marketing concepts and methods, selling techniques and principles to the workplace literacy program for the purpose of assisting individuals involved in promoting and selling these programs. Part I provides a rationale for marketing and discusses the following: the role of the sponsor in marketing, market versus marketing,…

  5. Transportation Exploration. Practical Arts. Instructor's Manual. Competency-Based Education.

    ERIC Educational Resources Information Center

    Keeton, Martha; And Others

    This manual provides curriculum materials for implementing a career exploration class in transportation occupations within a Practical Arts Education program for middle/junior high school students. Introductory materials include the program master sequence, a list of transportation occupations (land, water and aerospace transportation families),…

  6. Design and performance of a large vocabulary discrete word recognition system. Volume 2: Appendixes. [flow charts and users manual

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The users manual for the word recognition computer program contains flow charts of the logical diagram, the memory map for templates, the speech analyzer card arrangement, minicomputer input/output routines, and assembly language program listings.

  7. Clinical Guidelines. Dental Hygiene Program.

    ERIC Educational Resources Information Center

    Branson, Bonnie

    This manual contains information concerning the policies and procedures of the Southern Illinois University-Carbondale Dental Hygiene Clinic. The manual is presented in a question/answer format for the information and convenience of dental hygiene students in the program, and is intended to answer their questions concerning clinical policies and…

  8. Construction Exploration. Practical Arts. Instructor's Manual. Competency-Based Education.

    ERIC Educational Resources Information Center

    Keeton, Martha; And Others

    This manual provides curriculum materials for implementing a career exploration class in construction occupations within a Practical Arts Education program for middle/junior high school students. Introductory materials include the program master sequence, a list of construction occupations, and an overview of the competency-based instructional…

  9. SOFEPL: A Plotting Postprocessor for ’SOFE’ User’s Manual.

    DTIC Science & Technology

    1981-11-01

    execution, (5) Program completion. The organization of these five tasks is shown in the macro-level flowchart , Figure 3. Program initialization creates data...Corporation publication number 60493800. 8. DISSPLA Beginners /Intermediate Manual, Volume 1, Integrated Software Systems Corp., San Diego, California. 9

  10. The Comprehensive Competencies Program Reference Manual. Volume I. Introduction.

    ERIC Educational Resources Information Center

    Taggart, Robert

    Chapter 1 of this reference manual is a summary of the comprehensive competencies program (CCP). It describes this system for organizing, implementing, managing, and efficiently delivering individualized self-paced instruction, combined with group and experience-based learning activities, using computer-assisted instruction. (The CCP covers not…

  11. The NASA/MSFC global reference atmospheric model: 1990 version (GRAM-90). Part 1: Technical/users manual

    NASA Technical Reports Server (NTRS)

    Justus, C. G.; Alyea, F. N.; Cunnold, D. M.; Jeffries, W. R., III; Johnson, D. L.

    1991-01-01

    A technical description of the NASA/MSFC Global Reference Atmospheric Model 1990 version (GRAM-90) is presented with emphasis on the additions and new user's manual descriptions of the program operation aspects of the revised model. Some sample results for the new middle atmosphere section and comparisons with results from a three dimensional circulation model are provided. A programmer's manual with more details for those wishing to make their own GRAM program adaptations is also presented.

  12. Interfacing Computer-Assisted Drafting and Design with the Building Loads Analysis and System Thermodynamics (BLAST) Program

    DTIC Science & Technology

    1992-10-01

    Manual CI APPENDIX D: Drawing Navigator Field Test D1 DISTRIBUTION Accesion For NTIS CRA&I OTIC TAB Unannouncea JustiteCdtOn By Distribution I "".i•I...methods replace manual methods, the automation will handle the data for the designer, thus reducing error and increasing throughput. However, the two...actively move data from one automation tool (CADD) to the other (the analysis program). This intervention involves a manual rekeying of data already in

  13. S.P.S.S. User's Manual #1-#4. Basic Program Construction in S.P.S.S.; S.P.S.S. Non-Procedural Statements and Procedural Commands; System Control Language and S.P.S.S.; Quick File Equate Statement Reference.

    ERIC Educational Resources Information Center

    Earl, Lorna L.

    This series of manuals describing and illustrating the Statistical Package for the Social Sciences (SPSS) was planned as a self-teaching instrument, beginning with the basics and progressing to an advanced level. Information on what the searcher must know to define the data and write a program for preliminary analysis is contained in manual 1,…

  14. Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Lee Kenneth

    2017-03-01

    This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.

  15. Small Scale Irrigation Systems: A Training Manual. Planning--Construction--Operation and Maintenance of Small Scale Irrigation Systems. A Two-Week In-Service Training Program for Peace Corps Volunteers. Training for Development. Peace Corps Information Collection & Exchange Training Manual No. T-13.

    ERIC Educational Resources Information Center

    Development Planning and Research Associates, Inc., Manhattan, KS.

    This manual provides materials for a two-week inservice training program for Peace Corps volunteers on the planning, construction, and operation and maintenance of small-scale irrigation systems. The workshop is designed to be given by two experienced professionals: one with practical knowledge of irrigation system design, operation, and…

  16. ZIP2DL: An Elastic-Plastic, Large-Rotation Finite-Element Stress Analysis and Crack-Growth Simulation Program

    NASA Technical Reports Server (NTRS)

    Deng, Xiaomin; Newman, James C., Jr.

    1997-01-01

    ZIP2DL is a two-dimensional, elastic-plastic finte element program for stress analysis and crack growth simulations, developed for the NASA Langley Research Center. It has many of the salient features of the ZIP2D program. For example, ZIP2DL contains five material models (linearly elastic, elastic-perfectly plastic, power-law hardening, linear hardening, and multi-linear hardening models), and it can simulate mixed-mode crack growth for prescribed crack growth paths under plane stress, plane strain and mixed state of stress conditions. Further, as an extension of ZIP2D, it also includes a number of new capabilities. The large-deformation kinematics in ZIP2DL will allow it to handle elastic problems with large strains and large rotations, and elastic-plastic problems with small strains and large rotations. Loading conditions in terms of surface traction, concentrated load, and nodal displacement can be applied with a default linear time dependence or they can be programmed according to a user-defined time dependence through a user subroutine. The restart capability of ZIP2DL will make it possible to stop the execution of the program at any time, analyze the results and/or modify execution options and resume and continue the execution of the program. This report includes three sectons: a theoretical manual section, a user manual section, and an example manual secton. In the theoretical secton, the mathematics behind the various aspects of the program are concisely outlined. In the user manual section, a line-by-line explanation of the input data is given. In the example manual secton, three types of examples are presented to demonstrate the accuracy and illustrate the use of this program.

  17. Additional Effect of Static Ultrasound and Diadynamic Currents on Myofascial Trigger Points in a Manual Therapy Program for Patients With Chronic Neck Pain: A Randomized Clinical Trial.

    PubMed

    Dibai-Filho, Almir Vieira; de Oliveira, Alessandra Kelly; Girasol, Carlos Eduardo; Dias, Fabiana Rodrigues Cancio; Guirro, Rinaldo Roberto de Jesus

    2017-04-01

    To assess the additional effect of static ultrasound and diadynamic currents on myofascial trigger points in a manual therapy program to treat individuals with chronic neck pain. A single-blind randomized trial was conducted. Both men and women, between ages 18 and 45, with chronic neck pain and active myofascial trigger points in the upper trapezius were included in the study. Subjects were assigned to 3 different groups: group 1 (n = 20) was treated with manual therapy; group 2 (n = 20) was treated with manual therapy and static ultrasound; group 3 (n = 20) was treated with manual therapy and diadynamic currents. Individuals were assessed before the first treatment session, 48 hours after the first treatment session, 48 hours after the tenth treatment session, and 4 weeks after the last session. There was no group-versus-time interaction for Numeric Rating Scale, Neck Disability Index, Pain-Related Self-Statement Scale, pressure pain threshold, cervical range of motion, and skin temperature (F-value range, 0.089-1.961; P-value range, 0.106-0.977). Moreover, we found no differences between groups regarding electromyographic activity (P > 0.05). The use of static ultrasound or diadynamic currents on myofascial trigger points in upper trapezius associated with a manual therapy program did not generate greater benefits than manual therapy alone.

  18. Management Guide to a Competency-Based Adult Education Program for Administrators, Counselors, Teachers. 1984-1985.

    ERIC Educational Resources Information Center

    Brevard Community Coll., Cocoa, FL.

    A 310 Special Demonstration Project was conducted in Florida to create a model of competency-based adult education (CBAE) based on the programs currently in existence. This manual, which was produced through the project, presents an overview of CBAE and explains in detail how to operate a CBAE program. The manual is organized in 11 sections. The…

  19. LAW ENFORCEMENT OFFICER TRAINING, BASIC COURSE, UNIT II, A UNIT OF THE OHIO LAW ENFORCEMENT OFFICERS' TRAINING PROGRAM, LEARNER'S MANUAL.

    ERIC Educational Resources Information Center

    REESE, ROBERT M.; AND OTHERS

    STUDENTS MAY USE THIS MANUAL IN A LAW ENFORCEMENT TRAINING PROGRAM FOR INSERVICE LAW ENFORCEMENT OFFICERS AND RECRUITS. IT WAS DEVELOPED BY A STATEWIDE COMMITTEE OF LAW ENFORCEMENT TRAINING CONSULTANTS, SPECIALISTS, AND AN ADVISORY COMMITTEE AND WAS TESTED BY A SUBJECT MATTER SPECIALIST IN A PILOT-CLASS STUDY. THE PROGRAM IS DESIGNED TO PROVIDE…

  20. Viscous wing theory development. Volume 2: GRUMWING computer program user's manual

    NASA Technical Reports Server (NTRS)

    Chow, R. R.; Ogilvie, P. L.

    1986-01-01

    This report is a user's manual which describes the operation of the computer program, GRUMWING. The program computes the viscous transonic flow over three-dimensional wings using a boundary layer type viscid-inviscid interaction approach. The inviscid solution is obtained by an approximate factorization (AFZ)method for the full potential equation. The boundary layer solution is based on integral entrainment methods.

  1. The Gas Laws and the Kinetic Theory: Curriculum Guide for the Thirteen-College Curriculum Program.

    ERIC Educational Resources Information Center

    Daniel, Army; And Others

    This booklet is both a teacher's manual and a student's manual in a series of booklets that make up the core of a Physical Science course designed for the freshman year of college and used by teachers in the 27 colleges participating in the Thirteen College Curriculum Program. This program is a curriculum revision project in support of 13…

  2. Fatigue strength reduction model: RANDOM3 and RANDOM4 user manual. Appendix 2: Development of advanced methodologies for probabilistic constitutive relationships of material strength models

    NASA Technical Reports Server (NTRS)

    Boyce, Lola; Lovelace, Thomas B.

    1989-01-01

    FORTRAN programs RANDOM3 and RANDOM4 are documented in the form of a user's manual. Both programs are based on fatigue strength reduction, using a probabilistic constitutive model. The programs predict the random lifetime of an engine component to reach a given fatigue strength. The theoretical backgrounds, input data instructions, and sample problems illustrating the use of the programs are included.

  3. DRDC Ottawa Participation in the SILENE Accident Dosimetry Intercomparison Exercise. June 10-21, 2002

    DTIC Science & Technology

    2002-11-01

    of CaF2:Mn and A120 3 TLDs for gamma-ray dosimetry ). In addition, DRDC Ottawa has recently substantially expanded its efforts in radiation dosimetry ...use of any real- time electronic dosimeter. Foils have long been proposed and used for criticality dosimetry (as well as for general monitoring of...ray Dosimetry DRDC Ottawa offers a number (over five) of various thermoluminescence dosimetry ( TLD ) systems. The choice of any particular TLD depends

  4. 32 CFR 2004.20 - National Industrial Security Program Operating Manual (NISPOM) [201(a)].

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false National Industrial Security Program Operating Manual (NISPOM) [201(a)]. 2004.20 Section 2004.20 National Defense Other Regulations Relating to National... that surface from industry, Executive Branch departments and agencies, or the NISPPAC. When consensus...

  5. Us in a Bus: A Transportation Manual for Head Start Programs.

    ERIC Educational Resources Information Center

    Education Development Center, Inc., Newton, MA.

    The purpose of this manual is to provide Head Start directors, transportation supervisors, and trainers with information and activities that will help develop, enhance, and maintain a safe and efficient transportation system for their programs. Contents are organized into three categories: safety procedures, planning a transportation system, and…

  6. Marketing and Retailing. A Curriculum Guide for a Two-Year Postsecondary Program.

    ERIC Educational Resources Information Center

    Overton, R. Jean; Proffitt, Sally

    This manual was developed to provide a comprehensive curriculum guideline for postsecondary marketing and retailing programs. It contains competence-based materials and integrates the Interstate Distributive Education Curriculum Consortium (IDECC) Learning Activity Packages into the curriculum. The first of seven chapters in this manual presents…

  7. New Mexico Statewide Assessment Program (NMSAP) Procedures Manual, 2007-2008

    ERIC Educational Resources Information Center

    New Mexico Public Education Department, 2007

    2007-01-01

    This manual has been prepared for all New Mexico Statewide Assessment Program (NMSAP) assessment administrators, teachers, school specialists, and principals. It includes information about the following topics: PED contacts, New Mexico Standards Based Assessments (SBA), Grades 3-8 and 11; New Mexico High School Competency Examination (NMHSCE);…

  8. Business and Office Exploration. Practical Arts. Instructor's Manual. Competency-Based Education.

    ERIC Educational Resources Information Center

    Keeton, Martha; And Others

    This manual provides curriculum materials for implementing a career exploration class in business and office occupations within a Practical Arts Education program for middle/junior high school students. Introductory materials include the program master sequence, list of business and office occupations, and an overview of the competency-based…

  9. Occupational Component. 36-Level Courses. Teacher Resource Manual. Integrated Occupational Program.

    ERIC Educational Resources Information Center

    Alberta Dept. of Education, Edmonton. Curriculum Branch.

    This 36-level occupational component of Integrated Occupational Program (IOP) consists of 8 occupational clusters composed of 20 occupational courses. Each course contains learning activities so that students in Alberta (Canada) may develop occupational concepts, skills, and attitudes. This teacher's manual consists of the following sections:…

  10. The Maine Sealant Manual for School-Based and School-Linked Dental Sealant Programs.

    ERIC Educational Resources Information Center

    Hayward, Kneka, Ed.

    This manual is designed for use by school personnel and dental personnel to aid in the development and maintenance of school-based or school-linked dental sealant programs. The sections include (1) "Introduction"; (2) "Guidelines" (school selection, school contacts, dental providers, target grades, and tooth selection…

  11. Blade loss transient dynamics analysis. Volume 3: User's manual for TETRA program

    NASA Technical Reports Server (NTRS)

    Black, G. R.; Gallardo, V. C.; Storace, A. S.; Sagendorph, F.

    1981-01-01

    The users manual for TETRA contains program logic, flow charts, error messages, input sheets, modeling instructions, option descriptions, input variable descriptions, and demonstration problems. The process of obtaining a NASTRAN 17.5 generated modal input file for TETRA is also described with a worked sample.

  12. Wisconsin Summer Library Program Manual, 1981. Merlin's Mid-Summer Magic.

    ERIC Educational Resources Information Center

    Kreigh, Helen, Comp.

    This manual provides librarians with suggestions and patterns for decorations, promotion, resources (print, nonprint, and human), and activities and events for a community cooperative program providing library services to children during the summertime. Several ways in which the theme, Merlin's Midsummer Magic could be developed are suggested;…

  13. Exploring Old Growth Forests: A Teacher's Manual.

    ERIC Educational Resources Information Center

    Lemieux, Chris; Powers, Jennene; Quinby, Peter; Schultz, Caroline; Stabb, Mark

    "Exploring Old Growth Forests" is an Ontario (Canada) program that provides secondary students with hands-on experiences in old growth forests. Activity-based and student-centered, the program aims to develop student awareness of the importance of old growth forests and the need to conserve them. This manual provides teachers with…

  14. Vocational Education Program/Course Inventory Form PCI. Explanation and Instructional Manual.

    ERIC Educational Resources Information Center

    California Occupational Information Coordinating Committee, Sacramento.

    This manual for teachers, administrators, and counselors both explains the Program/Course Inventory (PCI), a data collection instrument, and provides instructions for completing the PCI form. The first section describes the PCI developed by the Ventura County Superintendent of Schools staff to collect data that define vocational education…

  15. Blissymbols and Manual Signs: A Multimodal Approach to Intervention in a Case of Multiple Disability.

    ERIC Educational Resources Information Center

    Hooper, Janice; And Others

    1987-01-01

    A multimodal intervention program designed for a nine-year-old with severe communication problems (secondary to cerebral palsy, receptive dysphasia, and auditory agnosia) combined manual signs and graphic symbols to help her communicate. The intensive, highly structured program had significant positive results. (Author/CB)

  16. 45 CFR 205.70 - Availability of agency program manuals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (AABD) of the Social Security Act must provide that: (a) Program manuals and other policy issuances... at a charge related to the cost of reproduction to public or university libraries, the local or.... Wide availability of agency policy materials is recommended. (c) Upon request, the agency will...

  17. Parent Child Center Program Management Information System. User's Manual.

    ERIC Educational Resources Information Center

    Warner, Donna D.; And Others

    This manual describes procedures for collecting, recording, and reporting in a uniform, timely manner critical information necessary to the making of key management decisions for parent child centers as well as for the parent child center program. The first section describes recommended data collection and recordkeeping procedures for such…

  18. America-Israel Young Ambassadors Student Exchange Program. Orientation Manual.

    ERIC Educational Resources Information Center

    Neeson, Eileen; And Others

    This orientation manual for the America-Israel Young Ambassadors Student Exchange Program is written for the exchange of high school students between these two countries. The goal is to familiarize American students with the history, politics, economy, religions and society of Israel. Thirteen training sessions are suggested on the following…

  19. Air Conditioning, Heating, and Refrigeration. Competency-Based Curriculum Manual.

    ERIC Educational Resources Information Center

    Gourley, Frank A., Jr.

    This manual was developed to serve as an aid to administrators and instructors involved with postsecondary air conditioning, heating, and refrigeration programs. The first of six chapters contains general information on program implementation, the curriculum design, facilities and equipment requirements, and textbooks and references. Chapter 2…

  20. Personal and Family Survival. Civil Defense Adult Education; Teacher's Manual.

    ERIC Educational Resources Information Center

    Office of Civil Defense (DOD), Washington, DC.

    A manual intended as an instructor's aid in presenting a Civil Defense Adult Education Course is presented. It contains 10 lesson plans: Course Introduction, Modern Weapons and Radioactive Fallout (Effects), Modern Weapons and Radioactive Fallout (Protection), National Civil Defense Program, National Shelter Program (Community Shelters), National…

  1. Southern Ductile Training Manual.

    ERIC Educational Resources Information Center

    Alabama State Dept. of Education, Montgomery.

    This instructor's manual contains the materials required to conduct the competency-based workplace literacy program that was developed to help employees at a foundry that has evolved from a small, family-owned business into a major foundry group with several automated production systems. The workplace literacy program consists of 24 lessons in…

  2. Hospitality and Recreation Occupations. Practical Arts. Instructor's Manual. Competency-Based Vocational Education.

    ERIC Educational Resources Information Center

    Keeton, Martha; And Others

    This manual provides curriculum materials for implementing a career exploration class in hospitality and recreation occupations within a Practical Arts Education program for middle/junior high school students. Introductory materials include the program master sequence, a list of hospitality and recreation occupations, and an overview of the…

  3. Highway Safety Program Manual: Volume 2: Motor Vehicle Registration.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 2 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) describes the purposes and specific objectives of motor vehicle registration. Federal authority for vehicle registration and general policies regarding vehicle registration systems are outlined.…

  4. Training Manual for HIV/AIDS Prevention.

    ERIC Educational Resources Information Center

    Epps, Patricia H.; Vallenari, Allison

    This manual includes all necessary information for implementing the Champs program, which trains older elementary school students or middle/high school students to operate puppets to deliver an HIV/AIDS message to kindergarten through sixth graders. Relying on a peer approach, the Program provides scripted, prerecorded lessons intended to reach…

  5. BASINs 4.0 Climate Assessment Tool (CAT): Supporting Documentation and User's Manual (Final Report)

    EPA Science Inventory

    EPA announced the availability of the report, BASINS 4.0 Climate Assessment Tool (CAT): Supporting Documentation and User's Manual. This report was prepared by the EPA's Global Change Research Program (GCRP), an assessment-oriented program, that sits within the Office of R...

  6. Creating a Market.

    ERIC Educational Resources Information Center

    Kazimirski, J.; And Others

    The second in a series of programmed books, "Creating a Market" is published by the International Labour Office as a manual for persons studying marketing. This manual was designed to meet the needs of the labor organization's technical cooperation programs and is primarily concerned with consumer goods industries. Using a fill-in-the-blanks and…

  7. Marketing and Distribution Occupations. Practical Arts. Instructor's Manual. Competency-Based Vocational Education.

    ERIC Educational Resources Information Center

    Keeton, Martha; And Others

    This manual provides curriculum materials for implementing a career exploration class in marketing and distribution occupations within a Practical Arts Education program for middle/junior high school students. Introductory materials include the program master sequence, a list of marketing and distribution occupations, and an overview of the…

  8. 76 FR 57723 - Agency Information Collection Activities: Proposed Collection; Comment Request; Election...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-16

    ...; Comment Request; Election Assistance Commission's Voting System Test Laboratory Program Manual, Version 1... Paperwork Reduction Act of 1995, the U.S. Election Assistance Commission (EAC) invites the general public... information collection, EAC's Voting System Test Laboratory Program Manual, Version 1.0. Comments are invited...

  9. Hospice Education Program for Nurses. Health Manpower References.

    ERIC Educational Resources Information Center

    HCS, Inc., Potomac, MD.

    This publication contains a curriculum to prepare nurses for delivery of hospice care for the terminally ill. It provides training manuals for both participant and facilitator in a preservice or inservice Hospice Education Program. Each manual (participant and facilitator) includes nine modules: (1) Hospice Care Concept; (2) Communication Skills;…

  10. Marine Science Exploration. Practical Arts. Instructor's Manual. Competency-Based Education.

    ERIC Educational Resources Information Center

    Keeton, Martha; McKinley, Douglas

    This manual provides curriculum materials for implementing a career exploration class in marine science occupations within a Practical Arts Education program for middle/junior high school students. Introductory materials include the program master sequence, a list of marine science occupations, and an overview of the competency-based instructional…

  11. CHAIRMAN'S WELCOME MESSAGE Chairman's message

    NASA Astrophysics Data System (ADS)

    Oldham, Mark

    2010-11-01

    Every clinical physicist I have asked readily acknowledges the great desirability of a 3D dosimetry system for the verification of advanced radiation therapy treatments. An accurate and practical 3D dosimetry system would greatly strengthen the foundation of quality assurance in radiation therapy by enabling a rigorous and comprehensive whole system test. Such systems are now emerging, and the innovations and progress that led to them are remarkably captured in the proceedings of five prior DOSGEL conferences, the last three of which are freely available in the Journal of Physics: Conference Series. These meetings included a focus on the technical challenges of various approaches to 3D dosimetry. When considering plans for the present 6th meeting, the scientific committee recognized that the field has matured, and a broader focus was desirable, including a strengthening of the clinical and applications component, while preserving a strong technical component. There was also the desire to embrace a variety of other semi-3D techniques which have also recently emerged to implementation in the clinic. In accordance with these sentiments, the committee approved changing the name of the conference from the International Conference on Radiotherapy Gel Dosimetry (DOSGEL) to the International Conference on 3D Radiation Dosimetry (IC3DDose) and to the following objectives - Conference Objectives: 1. To provide a forum to discuss the latest research and developments in 3D and advanced radiation dosimetry. 2. To elevate the quality of radiation therapy treatments (quality assurance QA) through improved clinical dosimetry. 3. To explore the dosimetric challenges posed by modern radiation treatment techniques 4. To energize and diversify dosimetry research and clinical practice by encouraging interaction and synergy between advanced, 3D, and semi-3D dosimetry techniques The scientific program of the IC3DDose2010 meeting has been crafted to meet the objectives listed above, and we were fortunate that many leading speakers shared their experience and perspectives to help achieve these aims. On a more personal note it was a true pleasure to extend a warm welcome to all conference attendees. We have a very diverse group of clinical and research physicists from many parts of the world, and it is truly a pleasure to welcome you all. Finally I would like to acknowledge the many people who have made the meeting possible. Special thanks go to the Scientific Organizing Committee (listed opposite) who reviewed all the conference abstracts and participated in many planning conference calls, and meeting activities. The Local Organizing Committee shouldered a significant load finalizing the conference abstract book and ensuring smooth meeting logistics. We are also very grateful to our sponsors, both academic and industrial, whose support was vital to this meeting. Mark Oldham, PhD, FAAPM Associate Professor, Radiation Oncology and Biomedical Engineering, Duke University Medical Center, Durham, NC, USA mark.oldham@duke.edu Chairman

  12. NASA Safety Manual. Volume 3: System Safety

    NASA Technical Reports Server (NTRS)

    1970-01-01

    This Volume 3 of the NASA Safety Manual sets forth the basic elements and techniques for managing a system safety program and the technical methods recommended for use in developing a risk evaluation program that is oriented to the identification of hazards in aerospace hardware systems and the development of residual risk management information for the program manager that is based on the hazards identified. The methods and techniques described in this volume are in consonance with the requirements set forth in NHB 1700.1 (VI), Chapter 3. This volume and future volumes of the NASA Safety Manual shall not be rewritten, reprinted, or reproduced in any manner. Installation implementing procedures, if necessary, shall be inserted as page supplements in accordance with the provisions of Appendix A. No portion of this volume or future volumes of the NASA Safety Manual shall be invoked in contracts.

  13. Parallel line analysis: multifunctional software for the biomedical sciences

    NASA Technical Reports Server (NTRS)

    Swank, P. R.; Lewis, M. L.; Damron, K. L.; Morrison, D. R.

    1990-01-01

    An easy to use, interactive FORTRAN program for analyzing the results of parallel line assays is described. The program is menu driven and consists of five major components: data entry, data editing, manual analysis, manual plotting, and automatic analysis and plotting. Data can be entered from the terminal or from previously created data files. The data editing portion of the program is used to inspect and modify data and to statistically identify outliers. The manual analysis component is used to test the assumptions necessary for parallel line assays using analysis of covariance techniques and to determine potency ratios with confidence limits. The manual plotting component provides a graphic display of the data on the terminal screen or on a standard line printer. The automatic portion runs through multiple analyses without operator input. Data may be saved in a special file to expedite input at a future time.

  14. Manual for Refugee Sponsorship.

    ERIC Educational Resources Information Center

    Brewer, Kathleen; Taran, Patrick A.

    This manual provides guidelines for religious congregations interested in setting up programs to sponsor refugees. The manual describes the psychological implications of the refugee experience and discusses initial steps in organizing for sponsorship. Detailed information is provided for sponsors regarding: finances and mobilization of resources;…

  15. The NASTRAN User's Manual (Level 15)

    NASA Technical Reports Server (NTRS)

    Mccormick, C. W. (Editor)

    1972-01-01

    The User's manual for the NASA Structural Analysis (NASTRAN) program is presented. The manual contains all information needed to solve problems with NASTRAN. The volume is instructional and encyclopedic. The manual includes instruction in structural modeling techniques, instruction in input preparation, and information to assist the interpretation of the output. Descriptions of all input data cards, restart procedures, and diagnostic messages are developed.

  16. Anger Management for Substance Abuse and Mental Health Clients: A Cognitive Behavioral Therapy Manual [and] Participant Workbook.

    ERIC Educational Resources Information Center

    Reilly, Patrick M.; Shopshire, Michael S.; Durazzo, Timothy C.; Campbell, Torri A.

    This manual and workbook set focuses on anger management. The manual was designed for use by qualified substance abuse and mental health clinicians who work with substance abuse and mental health clients with concurrent anger programs. The manual describes a 12-week cognitive behavioral anger management group treatment. Each of the 12 90-minute…

  17. Command Post Program Study. Volume 1 - Main Report

    DTIC Science & Technology

    1973-03-01

    Field Manual 30-9, Military Intelligence Battalion - Field Am. Washington: March 1968. _ Field Manual 32-20, Electronic Warfare. Washington: 14...Mechanized). A-18 TOE 30-88T, Military Intelligence Support Detachment, Military Intelligence Battalion, Field Army. TOE 30-206T, Headquarters and... Field Manual 30-9, Military Intelligence Battalion - Field Army. Washington: March 1968. _ Field Manual 32-20, Electronic Warfare. Washington: 14

  18. TU-F-201-00: Radiochromic Film Dosimetry Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less

  19. TU-F-201-01: General Aspects of Radiochromic Film Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niroomand-Rad, A.

    Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less

  20. User's manual for UCAP: Unified Counter-Rotation Aero-Acoustics Program

    NASA Technical Reports Server (NTRS)

    Culver, E. M.; Mccolgan, C. J.

    1993-01-01

    This is the user's manual for the Unified Counter-rotation Aeroacoustics Program (UCAP), the counter-rotation derivative of the UAAP (Unified Aero-Acoustic Program). The purpose of this program is to predict steady and unsteady air loading on the blades and the noise produced by a counter-rotation Prop-Fan. The aerodynamic method is based on linear potential theory with corrections for nonlinearity associated with axial flux induction, vortex lift on the blades, and rotor-to-rotor interference. The theory for acoustics and the theory for individual blade loading and wakes are derived in Unified Aeroacoustics Analysis for High Speed Turboprop Aerodynamics and Noise, Volume 1 (NASA CR-4329). This user's manual also includes a brief explanation of the theory used for the modelling of counter-rotation.

  1. User's manual for UCAP: Unified Counter-Rotation Aero-Acoustics Program

    NASA Astrophysics Data System (ADS)

    Culver, E. M.; McColgan, C. J.

    1993-04-01

    This is the user's manual for the Unified Counter-rotation Aeroacoustics Program (UCAP), the counter-rotation derivative of the UAAP (Unified Aero-Acoustic Program). The purpose of this program is to predict steady and unsteady air loading on the blades and the noise produced by a counter-rotation Prop-Fan. The aerodynamic method is based on linear potential theory with corrections for nonlinearity associated with axial flux induction, vortex lift on the blades, and rotor-to-rotor interference. The theory for acoustics and the theory for individual blade loading and wakes are derived in Unified Aeroacoustics Analysis for High Speed Turboprop Aerodynamics and Noise, Volume 1 (NASA CR-4329). This user's manual also includes a brief explanation of the theory used for the modelling of counter-rotation.

  2. Thermoluminescent dosimetry in veterinary diagnostic radiology.

    PubMed

    Hernández-Ruiz, L; Jimenez-Flores, Y; Rivera-Montalvo, T; Arias-Cisneros, L; Méndez-Aguilar, R E; Uribe-Izquierdo, P

    2012-12-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. A comparison of home-based exercise programs with and without self-manual therapy in individuals with knee osteoarthritis in community.

    PubMed

    Cheawthamai, Kornkamon; Vongsirinavarat, Mantana; Hiengkaew, Vimonwan; Saengrueangrob, Sasithorn

    2014-07-01

    The present study aimed to compare the effectiveness of the treatment programs of home-based exercise with and without self-manual therapy in individuals with knee osteoarthritis (knee OA) in community. Forty-three participants with knee OA were randomly assigned in groups. All participants received the same home-based exercise program with or without self-manual therapy over 12 weeks. Outcome measures were pain intensity, range of motions, six-minute walk test distance, the knee injury and osteoarthritis outcome score (KOOS), short-form 36 (SF-36) and satisfaction. The results showed that the self-manual therapy program significantly decreased pain at 4 weeks, increased flexion and extension at 4 and 12 weeks, and improved the KOOS in pain item and SF-36 in physical function and mental health items. The home-based exercise group showed significant increase of the six-minute walk distance at 4 and 12 weeks, improvements in the KOOS in pain and symptom items and SF-36 in the physical function and role-emotional items. Overall, the results favored a combination of self-manual therapy and home-based exercise for patients with knee OA, which apparently showed superior benefits in decreasing pain and improving active knee range of motions.

  4. Annual report on the AECB research and support program, 1997--1998. Report number INFO-0698

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-31

    The AECB-funded extramural Research and Support Program provides access to independent advice, expertise, and information via contracts placed in the private sector and with other agencies and organizations in Canada and elsewhere. This report presents information on the scope of activities in the Program during the year and describes how the Program was managed, organized, and carried out. Information on individual sub-programs is presented in such fields as nuclear reactors, fuel cycle facilities, uranium mines and mills, waste management, dosimetry, health physics, and regulatory process development. A list of individual projects and their expenditures is appended.

  5. Manual dexterity aptitude testing: a soap carving study.

    PubMed

    Tang, Christopher G; Hilsinger, Raymond L; Cruz, Raul M; Schloegel, Luke J; Byl, Fred M; Rasgon, Barry M

    2014-03-01

    Currently there are few validated metrics for predicting surgical skill among otolaryngology residency applicants. To determine whether manual dexterity aptitude testing in the form of soap carving during otolaryngology residency interviews at Kaiser Permanente Medical Center Oakland predicts surgical skill at the time of graduation from otolaryngology residency programs. This study was conducted to determine how applicants with the best and worst soap carvings compared at the time of graduation with respect to various metrics including visuospatial ability and manual dexterity. Over the last 25 years, applicants to the residency program at Kaiser Permanente Oakland were required to carve soap during their residency interview. The 3 best and 3 worst soap carvings from 1990 through 2006 were determined. Of the individuals who carved those soaps, 62 qualified for the study and matriculated into otolaryngology residency programs. Surveys were sent to the 62 individuals' residency programs to evaluate those individuals on a 5-point Likert scale in various categories as well as to rank those individuals as being in the top 50% or bottom 50% of their graduating class. All else being equal, we hypothesized that applicants who had the manual dexterity and visuospatial skills to accurately carve a bar of soap would more likely possess the skills necessary to become a good surgeon. There was no difference between individuals with the best soap carvings and those with the worst soap carvings in all categories: cognitive knowledge, visuospatial ability, manual dexterity, decision making, and overall score (P > .10 for all categories). There was a 95% response rate, with 35 of 37 residency programs responding and 59 of 62 surveys returned. Manual dexterity aptitude testing in the form of soap carving does not appear to correlate with surgical skill at the time of graduation. Further studies need to be conducted to determine the role of manual dexterity and visuospatial aptitude testing in the otolaryngology application process.

  6. Analysis and comparison of five contractor safety and health manuals (EG and G, SR II, ORNL, Ashland, and MLGW)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crowder, C.; Hurley, T.

    1981-03-01

    An analysis is presented of five safety and health contractor manuals against the requirements of the FE OSH Manual (FE 5480.1), and a breakdown in chart form of how the manuals compare to each other is given. It is pointed out that the manuals are inadequate, but that site visits will be necessary to determine the actual comprehensiveness of the facilities' safety and health programs.

  7. Noise produced by turbulent flow into a rotor: Users manual for noise calculation

    NASA Technical Reports Server (NTRS)

    Amiet, R. K.; Egolf, C. G.; Simonich, J. C.

    1989-01-01

    A users manual for a computer program for the calculation of noise produced by turbulent flow into a helicopter rotor is presented. These inputs to the program are obtained from the atmospheric turbulence model and mean flow distortion calculation, described in another volume of this set of reports. Descriptions of the various program modules and subroutines, their function, programming structure, and the required input and output variables are included. This routine is incorporated as one module of NASA's ROTONET helicopter noise prediction program.

  8. Synfuel program analysis. Volume 2: VENVAL users manual

    NASA Astrophysics Data System (ADS)

    Muddiman, J. B.; Whelan, J. W.

    1980-07-01

    This volume is intended for program analysts and is a users manual for the VENVAL model. It contains specific explanations as to input data requirements and programming procedures for the use of this model. VENVAL is a generalized computer program to aid in evaluation of prospective private sector production ventures. The program can project interrelated values of installed capacity, production, sales revenue, operating costs, depreciation, investment, dent, earnings, taxes, return on investment, depletion, and cash flow measures. It can also compute related public sector and other external costs and revenues if unit costs are furnished.

  9. User's Manual for FSLIP-3, FLEXSTAB Loads Integration Program

    NASA Technical Reports Server (NTRS)

    Sims, R. L.

    1981-01-01

    The FSLIP program documentation and user's manual is presented. As a follow on program to the FLEXSTAB computer analysis system, the primary function of this FORTRAN IV program is to integrate panel pressure coefficients computed by FLEXSTAB to obtain total shear, bending, and torque airloads on various surfaces, summed relative to user specified axes. The program essentially replaces the ALOADS module in FLEXSTAB with expanded capabilities and flexibility. As such, FSLIP is generalized to work on any FLEXSTAB model or other pressure data if in a compatible format.

  10. Radar Ocean Wave Spectrometer (ROWS) preprocessing program (PREROWS2.EXE). User's manual and program description

    NASA Technical Reports Server (NTRS)

    Vaughn, Charles R.

    1993-01-01

    This Technical Memorandum is a user's manual with additional program documentation for the computer program PREROWS2.EXE. PREROWS2 works with data collected by an ocean wave spectrometer that uses radar (ROWS) as an active remote sensor. The original ROWS data acquisition subsystem was replaced with a PC in 1990. PREROWS2.EXE is a compiled QuickBasic 4.5 program that unpacks the recorded data, displays various variables, and provides for copying blocks of data from the original 8mm tape to a PC file.

  11. A linear programming approach for placement of applicants to academic programs.

    PubMed

    Kassa, Biniyam Asmare

    2013-01-01

    This paper reports a linear programming approach for placement of applicants to study programs developed and implemented at the college of Business & Economics, Bahir Dar University, Bahir Dar, Ethiopia. The approach is estimated to significantly streamline the placement decision process at the college by reducing required man hour as well as the time it takes to announce placement decisions. Compared to the previous manual system where only one or two placement criteria were considered, the new approach allows the college's management to easily incorporate additional placement criteria, if needed. Comparison of our approach against manually constructed placement decisions based on actual data for the 2012/13 academic year suggested that about 93 percent of the placements from our model concur with the actual placement decisions. For the remaining 7 percent of placements, however, the actual placements made by the manual system display inconsistencies of decisions judged against the very criteria intended to guide placement decisions by the college's program management office. Overall, the new approach proves to be a significant improvement over the manual system in terms of efficiency of the placement process and the quality of placement decisions.

  12. Livestock Nutrition and Feeding. Student Manual. Second Edition.

    ERIC Educational Resources Information Center

    Ridenour, Harlan E.

    This manual is designed to help agricultural education students and teachers to apply scientific facts and principles to problem-solving procedures in determining nutritious and economical livestock feeding programs. The manual provides applied scientific activities in biological science and chemistry, mathematics, and communication skills. It…

  13. Dental Charting. Student's Manual.

    ERIC Educational Resources Information Center

    Weaver, Trudy Karlene; Apfel, Maura

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: dental anatomical terminology; tooth numbering systems;…

  14. Motor Development: Manual of Alternative Procedures.

    ERIC Educational Resources Information Center

    McCormack, James E.

    The manual of alternative procedures for teaching handicapped children focuses on programming, planning, and implementing training in the gross motor (posture, limb control, locomotion) and fine motor (facial, digital) skills. The manual consists of the following sections: specific teaching tactics commonly used in motor training stiuations…

  15. The performance of an automatic acoustic-based program classifier compared to hearing aid users' manual selection of listening programs.

    PubMed

    Searchfield, Grant D; Linford, Tania; Kobayashi, Kei; Crowhen, David; Latzel, Matthias

    2018-03-01

    To compare preference for and performance of manually selected programmes to an automatic sound classifier, the Phonak AutoSense OS. A single blind repeated measures study. Participants were fit with Phonak Virto V90 ITE aids; preferences for different listening programmes were compared across four different sound scenarios (speech in: quiet, noise, loud noise and a car). Following a 4-week trial preferences were reassessed and the users preferred programme was compared to the automatic classifier for sound quality and hearing in noise (HINT test) using a 12 loudspeaker array. Twenty-five participants with symmetrical moderate-severe sensorineural hearing loss. Participant preferences of manual programme for scenarios varied considerably between and within sessions. A HINT Speech Reception Threshold (SRT) advantage was observed for the automatic classifier over participant's manual selection for speech in quiet, loud noise and car noise. Sound quality ratings were similar for both manual and automatic selections. The use of a sound classifier is a viable alternative to manual programme selection.

  16. Stirling engine design manual, 2nd edition

    NASA Technical Reports Server (NTRS)

    Martini, W. R.

    1983-01-01

    This manual is intended to serve as an introduction to Stirling cycle heat engines, as a key to the available literature on Stirling engines and to identify nonproprietary Stirling engine design methodologies. Two different fully described Stirling engines are discussed. Engine design methods are categorized as first order, second order, and third order with increased order number indicating increased complexity. FORTRAN programs are listed for both an isothermal second order design program and an adiabatic second order design program. Third order methods are explained and enumerated. In this second edition of the manual the references are updated. A revised personal and corporate author index is given and an expanded directory lists over 80 individuals and companies active in Stirling engines.

  17. Evaluating community and campus environmental public health programs.

    PubMed

    Pettibone, Kristianna G; Parras, Juan; Croisant, Sharon Petronella; Drew, Christina H

    2014-01-01

    The National Institute of Environmental Health Sciences' (NIEHS) Partnerships for Environmental Public Health (PEPH) program created the Evaluation Metrics Manual as a tool to help grantees understand how to map out their programs using a logic model, and to identify measures for documenting their achievements in environmental public health research. This article provides an overview of the manual, describing how grantees and community partners contributed to the manual, and how the basic components of a logic model can be used to identify metrics. We illustrate how the approach can be implemented, using a real-world case study from the University of Texas Medical Branch, where researchers worked with community partners to develop a network to address environmental justice issues.

  18. Comparing the effects of manual therapy versus electrophysical agents in the management of knee osteoarthritis.

    PubMed

    Ali, Syed Shahzad; Ahmed, Syed Imran; Khan, Muhammad; Soomro, Rabail Rani

    2014-07-01

    To evaluate the effectiveness of Manual Therapy in comparison to Electrophysical agents in Knee Osteoarthritis. Total 50 patients with knee osteoarthritis were recruited from OPD of orthopedics civil hospital and Institute Of Physical Medicine & Rehabilitation, Dow University of Health Sciences Karachi. All those patients who fulfilled inclusion criteria were selected on voluntary basis. Selected patients were equally divided and randomly assigned into two groups with age and gender matching. The Manual therapy group received program of Maitland joint mobilization whereas Electrophysical Agent group received a program of TENS and cold pack. Both group received a program of exercise therapy as well. Patients received 3 treatment sessions per week for 4 successive weeks. Clinical assessment was performed using WOMAC index at baseline and on 12th treatment session. Both study groups showed clinically and statistically considerable improvements in WOMAC index. However, Related 2 sample t-test showed better clinical results in Manual Therapy group (p = 0.000) than Electrophysical Agents group (p = 0.008). The mean improvement in total WOMAC index was relatively higher in Manual Therapy group (22.36 ± 13.91) than Electrophysical Agent group (9.72 ± 6.10). This study concluded that manual therapy is clinically more effective in decreasing pain, stiffness and improving physical function in knee osteoarthritis.

  19. Look and Do Ancient Greece. Teacher's Manual: Primary Program, Greek Art & Architecture [and] Workbook: The Art and Architecture of Ancient Greece [and] K-4 Videotape. History through Art and Architecture.

    ERIC Educational Resources Information Center

    Luce, Ann Campbell

    This resource, containing a teacher's manual, reproducible student workbook, and a color teaching poster, is designed to accompany a 21-minute videotape program, but may be adapted for independent use. Part 1 of the program, "Greek Architecture," looks at elements of architectural construction as applied to Greek structures, and…

  20. Quality Care for School-Age Children: A Self-Instructional Guide To Help Staff Plan and Implement a Quality Program for School-Age Children.

    ERIC Educational Resources Information Center

    Childcare Resources, Birmingham, AL.

    The purpose of this manual is to provide school-age child care center staff in Alabama with information about school-age children that facilitates program planning and provides a basis for implementing and evaluating a high quality school-age child care (SACC) program. Sections of the manual discuss: (1) teacher competencies addressed by the…

  1. NECAP 4.1: NASA's energy-cost analysis program user's manual

    NASA Technical Reports Server (NTRS)

    Jensen, R. N.; Henninger, R. H.; Miner, D. L.

    1983-01-01

    The Enery Cost Analysis Program (NECAP) is a powerful computerized method to determine and to minimize building energy consumption. The program calculates hourly heat gain or losses taking into account the building thermal resistance and mass, using hourly weather and a "response factor' method. Internal temperatures are allowed to vary in accordance with thermostat settings and equipment capacity. A simplified input procedure and numerous other technical improvements are presented. This Users Manual describes the program and provides examples.

  2. Real-Time Multiprocessor Programming Language (RTMPL) user's manual

    NASA Technical Reports Server (NTRS)

    Arpasi, D. J.

    1985-01-01

    A real-time multiprocessor programming language (RTMPL) has been developed to provide for high-order programming of real-time simulations on systems of distributed computers. RTMPL is a structured, engineering-oriented language. The RTMPL utility supports a variety of multiprocessor configurations and types by generating assembly language programs according to user-specified targeting information. Many programming functions are assumed by the utility (e.g., data transfer and scaling) to reduce the programming chore. This manual describes RTMPL from a user's viewpoint. Source generation, applications, utility operation, and utility output are detailed. An example simulation is generated to illustrate many RTMPL features.

  3. The Coping Cat Program for Anxious Youth: The FEAR Plan Comes to Life

    ERIC Educational Resources Information Center

    Podell, Jennifer L.; Mychailyszyn, Matthew; Edmunds, Julie; Puleo, Connor M.; Kendall, Philip C.

    2010-01-01

    Manual-based treatments (therapist manuals, child workbooks) exist for the treatment of anxiety disorders in youth. The current article describes a cognitive-behavioral treatment program, "Coping Cat", for childhood anxiety, with an emphasis on its flexible application and implementation as well as video components to demonstrate aspects of the…

  4. Reference Manual for the Instructional Use of Microcomputers. Volume I (Release II).

    ERIC Educational Resources Information Center

    Forman, Denyse; And Others

    This manual is intended to provide educators with information and guidelines for locating, selecting, and purchasing commercially available courseware for the Apple II microcomputer. A courseware index is provided which lists programs in broad subject areas and grade levels. Information given for each program includes its DOS, language, cost,…

  5. District 1199C Training & Upgrading Fund. A Manual for Union-Management Educational Partnerships.

    ERIC Educational Resources Information Center

    Ryan, James T.

    This manual provides guidelines for developing and implementing employee educational programs with the cooperation of unions and management. It establishes the need for such programs by explaining the current and future demographics of the workplace, then suggests ways to determine the need for education in any particular company. Information…

  6. Resource Manual on the Use of Computers in Schooling.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Technology Applications.

    This resource manual is designed to provide educators with timely information on the use of computers and related technology in schools. Section one includes a review of the new Bureau of Technology Applications' goal, functions, and major programs and activities; a description of the Model Schools Program, which has been conceptually derived from…

  7. Team Development Manual. Family Nurse Practitioner/Physician Assistant Program.

    ERIC Educational Resources Information Center

    Dostal, Lori

    A manual is presented to help incorporate team development into training programs for nurse practitioners, physician assistants, and primary care physicians. It is also directed to practitioners who wish to improve teamwork and is designed to improve the utilization of the nurse practitioners and physician assistants. A group of one or more…

  8. Swimming for the Handicapped: A Manual for the Aide.

    ERIC Educational Resources Information Center

    Priest, Louise

    Presented is the American National Red Cross Swimming for the Handicapped Program manual designed for volunteer aides. The program's aims, scope, and value are described in the introduction. It is noted that the nonswimming aides can play a vital role in transportation, dressing room assistance, record keeping, and as safety assistants, while…

  9. Academic Peer Instruction: Reference and Training Manual (with Answers)

    ERIC Educational Resources Information Center

    Zaritsky, Joyce; Toce, Andi

    2013-01-01

    This manual consists of an introduction to our Academic Peer Instruction (API) program at LaGuardia Community College, a compilation of the materials we have developed and use for training of our tutors (with answers), and a bibliography. API is based on an internationally recognized peer tutoring program, Supplemental Instruction. (Contains 6…

  10. Laboratory Manual (For Concrete Instruction Course); Instructor's Guide, Pilot Program Edition.

    ERIC Educational Resources Information Center

    Portland Cement Association, Cleveland, OH.

    This laboratory manual, prepared for a 2-year program in junior colleges and technical institutes, is designed to accompany the instructional materials to train persons for employment as technicians in the cement and concrete industries. Included are 16 laboratory assignments for each of the following: (1) Principles of Concrete, (2) Concrete in…

  11. Attrition Cost Model Instruction Manual

    ERIC Educational Resources Information Center

    Yanagiura, Takeshi

    2012-01-01

    This instruction manual explains in detail how to use the Attrition Cost Model program, which estimates the cost of student attrition for a state's higher education system. Programmed with SAS, this model allows users to instantly calculate the cost of attrition and the cumulative attrition rate that is based on the most recent retention and…

  12. Structural tailoring of advanced turboprops (STAT): User's manual

    NASA Technical Reports Server (NTRS)

    Brown, K. W.

    1991-01-01

    This user's manual describes the Structural Tailoring of Advanced Turboprops program. It contains instructions to prepare the input for optimization, blade geometry and analysis, geometry generation, and finite element program control. In addition, a sample input file is provided as well as a section describing special applications (i.e., non-standard input).

  13. Body Power! School-Based Weight Management for Middle School Adolescents. Leader's Manual.

    ERIC Educational Resources Information Center

    Dennee, Phyllis M.; And Others

    This leader's manual contains the materials required to present a school-based weight management curriculum that may be offered both in school and outside the school setting for middle-school adolescents. The first section contains instructor information regarding the following topics: need for the program; program objectives; timeline and…

  14. Students in Transition Using Planning. Teacher's Manual.

    ERIC Educational Resources Information Center

    PACER Center, Inc., Minneapolis, MN.

    The manual was the outcome of a 3-year project to develop a training program on self-advocacy for special education students. The student training is a 3-4 hour program aimed at increased student awareness of their rights and responsibilities as they begin the transition process. Training materials include outlines for each session, student…

  15. Programs Under Bilingual Education Act (Title VII, ESEA): Manual for Project Applicants and Grantees.

    ERIC Educational Resources Information Center

    Bureau of Elementary and Secondary Education (DHEW/OE), Washington, DC.

    The Bilingual Education Program, designed to help children having limited English-speaking ability develop greater competence in English, become more proficient in their dominant language, and profit from increased educational opportunity, is described in this manual for project applicants and grantees. Eight chapters include a review of: (1)…

  16. Law Enforcement Officer Training, Basic Course. Learner's Manual.

    ERIC Educational Resources Information Center

    Ohio State Dept. of Education, Columbus. Trade and Industrial Education Service.

    Developed by the State Division of Vocational Education, this learner's manual is designed to provide law enforcement officers with a better understanding of the many problems involved in providing good law enforcement services. The objectives of this program are to determine local, county, regional and state needs, to implement a program to meet…

  17. LAW ENFORCEMENT OFFICER TRAINING, BASIC COURSE, UNIT II, INSTRUCTOR'S MANUAL.

    ERIC Educational Resources Information Center

    REESE, ROBERT M.; AND OTHERS

    INSTRUCTORS MAY USE THIS MANUAL IN CONDUCTING A TRAINING PROGRAM FOR INSERVICE LAW ENFORCEMENT OFFICERS AND RECRUITS. IT WAS DEVELOPED BY A STATEWIDE COMMITTEE OF STATE LAW ENFORCEMENT CONSULTANTS, SPECIALISTS, AND AN ADVISORY COMMITTEE AND WAS TESTED BY A SUBJECT-MATTER SPECIALIST IN PILOT-CLASS STUDY. THE TRAINING PROGRAM IS DESIGNED TO PROVIDE…

  18. Occupational Safety and Health Curriculum Manual.

    ERIC Educational Resources Information Center

    Gourley, Frank A., Jr., Comp.

    With the enactment of the Occupational Safety and Health Act of 1970, the need for manpower development in the field of industrial safety and hygiene has resulted in the development of a broad based program in Occupational Safety and Health. The manual provides information to administrators and instructors on a program of study in this field for…

  19. Katimavik Participant's Manual, Book X, International Awareness = Katimavik manuel du participant, cahier X, sensibilisation a la vie internationale.

    ERIC Educational Resources Information Center

    Crelinsten, Michael, Ed.

    Devoted to the international awareness learning activities of Katimavik (a nine-month volunteer community service and experiential learning program for 17 to 21 year old Canadians), the bilingual student manual contains sections on learning program objectives and trimester guidelines, optional activities, resume recordkeeping, global perspectives…

  20. 75 FR 52625 - Amendment to the International Traffic in Arms Regulations: Export Exemption for Technical Data

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... the provisions of the Department of Defense National Industrial Security Program Operating Manual, an... Department of Defense National Industrial Security Program Operating Manual (unless such requirements are in..., Arms Control and International Security, Department of State. [FR Doc. 2010-21450 Filed 8-26-10; 8:45...

  1. Katimavik Participant's Manual, Book IX, Active Leisure = Katimavik manuel du participant, cahier IX, loisirs actifs.

    ERIC Educational Resources Information Center

    Crelinsten, Michael, Ed.

    The bilingual student manual, devoted to the active leisure learning activity portion of Katimavik (the nine-month volunteer community service and experiential learning program for 17 to 21 year old Canadians) contains sections on learning program objectives and trimester guidelines; optional activities; resume recordkeeping; general information…

  2. OECHC Program Review Guide. A Manual of Standard Operating Procedures. Revised.

    ERIC Educational Resources Information Center

    New York State Education Dept. Albany. Office for the Education of Children with Handicapping Conditions.

    The program review guide provides a framework and a source of reference for the monitoring staff of the New York State Education Department's Office for Education of Children with Handicapping Conditions. The manual simultaneously provides a means for school districts, the Boards of Cooperative Educational Services, and other agencies to monitor…

  3. Immersion francaise precoce: Francais I (Early French Immersion: French I).

    ERIC Educational Resources Information Center

    Burt, Andy; And Others

    This manual for first grade French instruction accompanies the early French immersion program. It is based on general and specific learning objectives for the four language skills the child needs to develop (listening, speaking, reading, and writing). The introduction to the manual provides an overview of the program for the primary grades and…

  4. School-Based Prevention of Bullying and Relational Aggression in Adolescence: The Fairplayer.manual

    ERIC Educational Resources Information Center

    Scheithauer, Herbert; Hess, Markus; Schultze-Krumbholz, Anja; Bull, Heike Dele

    2012-01-01

    The fairplayer.manual is a school-based program to prevent bullying. The program consists of fifteen to seventeen consecutive ninety-minute lessons using cognitive-behavioral methods, methods targeting group norms and group dynamics, and discussions on moral dilemmas. Following a two-day training session, teachers, together with skilled…

  5. Tsunami Summer! 2003 Young Adult Summer Library Program.

    ERIC Educational Resources Information Center

    Alabama Public Library Service, Montgomery.

    This manual is designed to assist public libraries in Alabama with setting up "Tsunami Summer!," a summer program for young adults, i.e., students in grades 6 through 12. The manual contains the following sections: (1) Publicity and Promotion; (2) Working with Schools; (3) Involving the Students, including teen volunteers, teen advisory…

  6. 26 CFR 1.861-18 - Classification of transactions involving computer programs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... income. In the case of a transfer of a copyrighted article, this section provides rules for determining... purposes of this paragraph (a)(3), a computer program includes any media, user manuals, documentation, data base or similar item if the media, user manuals, documentation, data base or similar item is incidental...

  7. 26 CFR 1.861-18 - Classification of transactions involving computer programs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... income. In the case of a transfer of a copyrighted article, this section provides rules for determining... purposes of this paragraph (a)(3), a computer program includes any media, user manuals, documentation, data base or similar item if the media, user manuals, documentation, data base or similar item is incidental...

  8. 26 CFR 1.861-18 - Classification of transactions involving computer programs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... income. In the case of a transfer of a copyrighted article, this section provides rules for determining... purposes of this paragraph (a)(3), a computer program includes any media, user manuals, documentation, data base or similar item if the media, user manuals, documentation, data base or similar item is incidental...

  9. Developmental Disabilities Manual, 1984-1985. Revised. Delta College Parent Awareness. Developmental Disabilities/Parent Awareness Program.

    ERIC Educational Resources Information Center

    Delta Coll., University Center, MI. Allied Health-Community Affairs.

    Developed as part of Delta College's Parent Awareness Program, this manual offers parents and family members of handicapped children explanations of the following conditions: mental retardation, cerebral palsy, epilepsy, learning disabilities, and autism. In the first section, "Special Parenting Information," Gerri Caesar describes her own…

  10. Intrasystem Analysis Program (IAP) Code Summaries.

    DTIC Science & Technology

    1983-05-01

    I - Ue’s Manual Engineering Section," RADC-TR-74-342, AD# A008526, December 1974. - 3. L. Bogdanor , R. A. Pearl--n, and M. .. Siegel, "Intrasystem...Electromagnetic Compatibility Analysis Program, Volume II - User’s Manual Usage Section," RADC-TR-74-342, AD# A008527, December 1974. i * J. L. Bogdanor

  11. Implementing PICKUP in LEA Colleges under the Education Reform Act 1988. A Guidance Manual.

    ERIC Educational Resources Information Center

    Thomas, David

    This manual on the provision of Professional, Industrial, and Commercial Updating (PICKUP) programming by colleges in England, Scotland, and Wales consists of a summary of recommendations, an introduction, 8 sections, and 11 appendices. Section 1 discusses planning; the requirements of the 1988 Education Reform Act; provision of programming;…

  12. Manualized-Group Treatment of Eating Disorders: Attunement in Mind, Body, and Relationship (AMBR)

    ERIC Educational Resources Information Center

    Cook-Cottone, Catherine; Beck, Meredith; Kane, Linda

    2008-01-01

    This article describes a manualized-group treatment of eating disorders, the attunement in mind, body, and relationship (AMBR) program. The cognitive behavioral and dialectic behavioral research as well as the innovative prevention interventions upon which the program is based (e.g., interactive discourse, yoga, and mediation) are introduced. The…

  13. Lifetime Planning Manual, 1984-1985. Delta College Parent Awareness. Developmental Disabilities/Parent Awareness Program.

    ERIC Educational Resources Information Center

    Delta Coll., University Center, MI. Allied Health-Community Affairs.

    Developed as part of Delta College's Parent Awareness Program, this manual provides information related to the special concerns of parents and families of developmentally disabled children, adolescents, and adults. The first section stresses the importance of planning and preparing for the future and establishing adequate financial and personal…

  14. A Program to Enhance the Effectiveness of Teaching Assistants.

    ERIC Educational Resources Information Center

    Cornell Univ., Ithaca, NY. Coll. of Engineering.

    This manual is the final report on a two-year project to enhance the effectiveness of teaching assistants. It is designed as a workbook for persons conducting instructional programs for teaching assistants and is specific to teaching assistants in engineering and the natural sciences. The manual contains an introduction and six chapters. Chapter…

  15. RBS Career Education. Evaluation Planning Manual. Education Is Going to Work.

    ERIC Educational Resources Information Center

    Kershner, Keith M.

    Designed for use with the Research for Better Schools career education program, this evaluation planning manual focuses on procedures and issues central to planning the evaluation of an educational program. Following a statement on the need for evaluation, nine sequential steps for evaluation planning are discussed. The first two steps, program…

  16. Small Scale Marine Fisheries: An Extension Training Manual. TR-30.

    ERIC Educational Resources Information Center

    Martinson, Steven; And Others

    This manual is designed for use in a preservice training program for prospective volunteers whose Peace Corps service will be spent working with small-scale artisanal fishing communities in developing nations. The program consists of 8 weeks of intensive training to develop competencies in marine fisheries technology and fisheries extension work…

  17. Intensive Reading Instructional Teams, Evaluation Manual for Project Directors.

    ERIC Educational Resources Information Center

    Nearine, Robert J.

    In this manual, project directors of the Intensive Reading Instructional Teams (IRIT) program in Hartford, Connecticut, public schools, are provided with suggestions for evaluating compensatory programs such as the IRIT. Three models for basic Title I evaluation are discussed and compared: a norm-referenced model, a control group design, and a…

  18. VAPEPS user's reference manual, version 5.0

    NASA Technical Reports Server (NTRS)

    Park, D. M.

    1988-01-01

    This is the reference manual for the VibroAcoustic Payload Environment Prediction System (VAPEPS). The system consists of a computer program and a vibroacoustic database. The purpose of the system is to collect measurements of vibroacoustic data taken from flight events and ground tests, and to retrieve this data and provide a means of using the data to predict future payload environments. This manual describes the operating language of the program. Topics covered include database commands, Statistical Energy Analysis (SEA) prediction commands, stress prediction command, and general computational commands.

  19. Manual Laboratorio de Microbiologia. Documento de trabajo Programa de Educacion en Ocupaciones de Salud (Microbiology Laboratory Manual. Curriculum Document. Program of Education in Health Occupations).

    ERIC Educational Resources Information Center

    Puerto Rico State Dept. of Education, Hato Rey. Area for Vocational and Technical Education.

    This laboratory manual on microbiology begins with an introduction relating the study of microorganisms to health occupations education and stressing the importance of teaching critical thinking. The introduction is followed by general instructions for the use of the manual and an illustration of hand washing procedures. The 13 laboratory…

  20. Solar and Energy Conserving Food Technologies: A Training Manual. Training for Development. Peace Corps Information Collection & Exchange Training Manual No. T-17.

    ERIC Educational Resources Information Center

    Farallones Inst., Occidental, CA.

    Based on experience in the field, this training manual was developed to help Peace Corps trainers plan and implement inservice training programs in solar and other energy conserving food technologies for Peace Corps volunteers and community workers. Using a competency-based format, the manual contains 20 sessions (learning modules) that focus on…

  1. A users' guide to the trace contaminant control simulation computer program

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    1994-01-01

    The Trace Contaminant Control Simulation computer program is a tool for assessing the performance of various trace contaminant control technologies for removing trace chemical contamination from a spacecraft cabin atmosphere. The results obtained from the program can be useful in assessing different technology combinations, system sizing, system location with respect to other life support systems, and the overall life cycle economics of a trace contaminant control system. The user's manual is extracted in its entirety from NASA TM-108409 to provide a stand-alone reference for using any version of the program. The first publication of the manual as part of TM-108409 also included a detailed listing of version 8.0 of the program. As changes to the code were necessary, it became apparent that the user's manual should be separate from the computer code documentation and be general enough to provide guidance in using any version of the program. Provided in the guide are tips for input file preparation, general program execution, and output file manipulation. Information concerning source code listings of the latest version of the computer program may be obtained by contacting the author.

  2. Dental Chairside Technique. Student's Manual.

    ERIC Educational Resources Information Center

    Apfel, Maura; Weaver, Trudy Karlene

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: local anesthesia; dental office emergencies; oral hygiene;…

  3. Project Developmental Continuity: PDC Classroom Observation Manual.

    ERIC Educational Resources Information Center

    Meece, Judy; And Others

    This classroom observation manual (Fall 1976) was developed for use in the evaluation of Project Developmental Continuity (PDC), a Head Start demonstration program aimed at providing educational and developmental continuity between children's Head Start and primary school experiences. The manual provides detailed instructions for the observer on…

  4. IPM for Pennsylvania Schools: A How-To Manual.

    ERIC Educational Resources Information Center

    Martz, Eston, Ed.

    This manual presents practical advice on planning and adopting an integrated pest management (IPM) program for Pennsylvania educational facilities. The manual covers how to implement a school IPM, school IPM operational information for the school administrator, and technical information for Pennsylvania schools concerning various pests found in…

  5. Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images.

    PubMed

    Leal Neto, Viriato; Vieira, José Wilson; Lima, Fernando Roberto de Andrade

    2014-01-01

    This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity.

  6. OFFSITE ENVIRONMENTAL MONITORING REPORT. RADIATION MONITORING AROUND UNITED STATES NUCLEAR TEST AREAS, CALENDAR YEAR 1981

    EPA Science Inventory

    This report, prepared in accordance with the guidelines in DOE/E-0023 (DOE 1981), covers the program activities conducted around Nevada Test Site (NTS) for calendar year 1981. It contains descriptions of pertinent features of the NTS and its environs, summaries of the dosimetry a...

  7. How Exposure Science can be Integrated into the Assessment of Ingredient Safety (American College of Toxicology Annual Meeting)

    EPA Science Inventory

    The presentation describes ongoing research in the Rapid Exposure and Dosimetry project funded under the Chemical Safety for Sustainability Research Program of the Office of Research and Development. There is a well known need for information on human exposure to thousands of che...

  8. High Throughput PBTK: Evaluating EPA’s Open-Source Data and Tools for Dosimetry and Exposure Reconstruction

    EPA Science Inventory

    Thousands of chemicals have been profiled by high-throughput screening (HTS) programs such as ToxCast and Tox21; these chemicals are tested in part because most of them have limited or no data on hazard, exposure, or toxicokinetics (TK). While HTS generates in vitro bioactivity d...

  9. INEL BNCT Research Program Annual Report 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhuizen, J.R.

    1994-08-01

    This report is a summary of the progress and research produced for the Idaho National Engineering Laboratory Boron Neutron Capture Therapy Research Program for calendar year 1993. Contributions from all the principal investigators are included, covering chemistry (pituitary tumor studies, boron drug development including liposomes, lipoproteins, and carboranylalanine derivatives), pharmacology (murine screenings, toxicity testing, boron drug analysis), physics (radiation dosimetry software, neutron beam and filter design, neutron beam measurement dosimetry), and radiation biology (tissue and efficacy studies of small and large animal models). Information on the potential toxicity of borocaptate sodium and boronophenylalanine is presented. Results of 21 spontaneous-tumor-bearing dogsmore » that have been treated with boron neutron capture therapy at the Brookhaven National Laboratory are updated. Boron-containing drug purity verification is discussed in some detail. Advances in magnetic resonance imaging of boron in vivo are discussed. Several boron-carrying drugs exhibiting good tumor uptake are described. Significant progress in the potential of treating pituitary tumors is presented. Measurement of the epithermal-neutron flux of the Petten (The Netherlands) High Flux Reactor beam (HFB11B), and comparison to predictions are shown.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiu-Tsao, S.

    Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less

  11. Slave finite element for non-linear analysis of engine structures. Volume 2: Programmer's manual and user's manual

    NASA Technical Reports Server (NTRS)

    Witkop, D. L.; Dale, B. J.; Gellin, S.

    1991-01-01

    The programming aspects of SFENES are described in the User's Manual. The information presented is provided for the installation programmer. It is sufficient to fully describe the general program logic and required peripheral storage. All element generated data is stored externally to reduce required memory allocation. A separate section is devoted to the description of these files thereby permitting the optimization of Input/Output (I/O) time through efficient buffer descriptions. Individual subroutine descriptions are presented along with the complete Fortran source listings. A short description of the major control, computation, and I/O phases is included to aid in obtaining an overall familiarity with the program's components. Finally, a discussion of the suggested overlay structure which allows the program to execute with a reasonable amount of memory allocation is presented.

  12. Users' manual for computer program for three-dimensional analysis of coupler-cavity traveling wave tubes

    NASA Technical Reports Server (NTRS)

    Omalley, T. A.

    1984-01-01

    The use of the coupled cavity traveling wave tube for space communications has led to an increased interest in improving the efficiency of the basic interaction process in these devices through velocity resynchronization and other methods. A flexible, three dimensional, axially symmetric, large signal computer program was developed for use on the IBM 370 time sharing system. A users' manual for this program is included.

  13. PISCES 2 users manual

    NASA Technical Reports Server (NTRS)

    Pratt, Terrence W.

    1987-01-01

    PISCES 2 is a programming environment and set of extensions to Fortran 77 for parallel programming. It is intended to provide a basis for writing programs for scientific and engineering applications on parallel computers in a way that is relatively independent of the particular details of the underlying computer architecture. This user's manual provides a complete description of the PISCES 2 system as it is currently implemented on the 20 processor Flexible FLEX/32 at NASA Langley Research Center.

  14. PREFACE: 8th International Conference on 3D Radiation Dosimetry (IC3DDose)

    NASA Astrophysics Data System (ADS)

    Olsson, Lars E.; Bäck, S.; Ceberg, Sofie

    2015-01-01

    IC3DDose 2014, the 8th International Conference on 3D Radiation Dosimetry was held in Ystad, Sweden, from 4-7 September 2014. This grew out of the DosGel series, which began as DosGel99, the 1st International Workshop on Radiation Therapy Gel Dosimetry in Lexington, Kentucky. Since 1999 subsequent DoSGel conferences were held in Brisbane, Australia (2001), Ghent, Belgium (2004), Sherbrooke, Canada (2006) and Crete, Greece (2008). In 2010 the conference was held on Hilton Head Island, South Carolina and underwent a name-change to IC3DDose. The 7th and last meeting was held in Sydney, Australia from 4-8 November 2012. It is worth remembering that the conference series started at the very beginning of the intensity modulated radiotherapy era and that the dosimeters being developed then were, to some extent, ahead of the clinical need of radiotherapy. However, since then the technical developments in radiation therapy have been dramatic, with dynamic treatments, including tracking, gating and volumetric modulated arc therapy, widely introduced in the clinic with the need for 3D dosimetry thus endless. This was also reflected by the contributions at the meeting in Ystad. Accordingly the scope of the meeting has also broadened to IC3DDOSE - I See Three-Dimensional Dose. A multitude of dosimetry techniques and radiation detectors are now represented, all with the common denominator: three-dimensional or 3D. Additionally, quality assurance (QA) procedures and other aspects of clinical dosimetry are represented. The implementation of new dosimetric techniques in radiotherapy is a process that needs every kind of caution, carefulness and thorough validation. Therefore, the clinical needs, reformulated as the aims for IC3DDOSE - I See Three-Dimensional Dose, are: • Enhance the quality and accuracy of radiation therapy treatments through improved clinical dosimetry. • Investigate and understand the dosimetric challenges of modern radiation treatment techniques. • Provide a forum to discuss the latest research and developments in 3D and advanced radiation dosimetry. • Energize and diversify dosimetry research and clinical practice by encouraging interaction and synergy between advanced, 3D, and semi-3D dosimetry techniques. We commend these IC3Dose 2014 conference proceedings to you and strongly believe they include significant contributions to scientific progress in this field. We would like to express our sincere gratitude to everybody involved in making the conference possible, the Scientific committee for their work on the general planning, paper review and program formulation, the distinguished invited speakers for their contributions and the local organizing committee members for all their hard work on the practical preparation for the meeting. Lars E. Olsson, Sven Bäck and Sofie Ceberg Lund University and Skåne University Hospital, Sweden International Scientific Committee Sven Bäck, Sweden (chair) Clive Baldock, Australia Sam Beddar, USA Crister Ceberg, Sweden Yves de Deene, Belgium/Australia Simon Doran, UK Geoffrey Ibbott, USA Andrew Jirasek, Canada Kevin Jordan, Canada Martin Lepage, Canada Daniel Low, USA Mark Oldham, USA Tony Popescu, Canada John Schreiner, Canada Cheng-Shie Wuu, USA David Thwaites, Australia Local Organizing Committee Sofie Ceberg (chair) Lars E. Olsson (conference chair) Fredrik Nordstrom Anneli Edvardsson Anna Karlsson Hauer Anna Bäck

  15. Training in Your Community for Tourism.

    ERIC Educational Resources Information Center

    Canei, Robert A.

    Because many different types of service occupations and industries may be involved with tourists, the manual has been developed so that the instructor may add or delete from its content. The manual contains topical outlines and suggestions for instructors in four sessions. Other sections for program development contained in the manual are agenda…

  16. Guidance Manual: Asbestos Operations & Maintenance Work Practices. Second Edition.

    ERIC Educational Resources Information Center

    National Inst. of Building Sciences, Washington, DC.

    This technical manual provides detailed guidance to building owners, asbestos program managers, and operations and maintenance (O&M) workers for managing asbestos-containing materials (ACM) in buildings. The manual addresses four different types of ACM found in buildings and three different levels of precaution which may be warranted by…

  17. Advanced Waste Treatment. A Field Study Training Program.

    ERIC Educational Resources Information Center

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This operations manual represents a continuation of operator training manuals developed for the United States Environmental Protection Agency (USEPA) in response to the technological advancements of wastewater treatment and the changing needs of the operations profession. It is intended to be used as a home-study course manual (using the concepts…

  18. Auto Mechanics; Methodology. Technical Instruction Manual.

    ERIC Educational Resources Information Center

    Systems Operation Support, Inc., King of Prussia, PA.

    This student instruction manual was written in conformance with selected criteria for programed instruction books as developed previously for various military training courses. The manual was developed as a part of "A Study of the Effectiveness of a Military-Type Computer-Based Instructional System When Used in Civilian High School Courses in…

  19. Industrial Waste Treatment. A Field Study Training Program.

    ERIC Educational Resources Information Center

    California State Univ., Sacramento. Dept. of Civil Engineering.

    This operations manual represents a continuation of operator training manuals developed for the United States Environmental Protection Agency (USEPA) in response to the technological advancements of wastewater treatment and the changing needs of the operations profession. It is intended to be used as a home-study course manual (using the concepts…

  20. Technical Manual. The ACT®

    ERIC Educational Resources Information Center

    ACT, Inc., 2014

    2014-01-01

    This manual contains technical information about the ACT® college readiness assessment. The principal purpose of this manual is to document the technical characteristics of the ACT in light of its intended purposes. ACT regularly conducts research as part of the ongoing formative evaluation of its programs. The research is intended to ensure that…

Top