Using lean to improve medication administration safety: in search of the "perfect dose".
Ching, Joan M; Long, Christina; Williams, Barbara L; Blackmore, C Craig
2013-05-01
At Virginia Mason Medical Center (Seattle), the Collaborative Alliance for Nursing Outcomes (CALNOC) Medication Administration Accuracy Quality Study was used in combination with Lean quality improvement efforts to address medication administration safety. Lean interventions were targeted at improving the medication room layout, applying visual controls, and implementing nursing standard work. The interventions were designed to prevent medication administration errors through improving six safe practices: (1) comparing medication with medication administration record, (2) labeling medication, (3) checking two forms of patient identification, (4) explaining medication to patient, (5) charting medication immediately, and (6) protecting the process from distractions/interruptions. Trained nurse auditors observed 9,244 doses for 2,139 patients. Following the intervention, the number of safe-practice violations decreased from 83 violations/100 doses at baseline (January 2010-March 2010) to 42 violations/100 doses at final follow-up (July 2011-September 2011), resulting in an absolute risk reduction of 42 violations/100 doses (95% confidence interval [CI]: 35-48), p < .001). The number of medication administration errors decreased from 10.3 errors/100 doses at baseline to 2.8 errors/100 doses at final follow-up (absolute risk reduction: 7 violations/100 doses [95% CI: 5-10, p < .001]). The "perfect dose" score, reflecting compliance with all six safe practices and absence of any of the eight medication administration errors, improved from 37 in compliance/100 doses at baseline to 68 in compliance/100 doses at the final follow-up. Lean process improvements coupled with direct observation can contribute to substantial decreases in errors in nursing medication administration.
Unit of Measurement Used and Parent Medication Dosing Errors
Dreyer, Benard P.; Ugboaja, Donna C.; Sanchez, Dayana C.; Paul, Ian M.; Moreira, Hannah A.; Rodriguez, Luis; Mendelsohn, Alan L.
2014-01-01
BACKGROUND AND OBJECTIVES: Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. METHODS: Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. RESULTS: Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2–4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03–3.5) dose; associations greater for parents with low health literacy and non–English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon–associated measurement errors. CONCLUSIONS: Findings support a milliliter-only standard to reduce medication errors. PMID:25022742
Unit of measurement used and parent medication dosing errors.
Yin, H Shonna; Dreyer, Benard P; Ugboaja, Donna C; Sanchez, Dayana C; Paul, Ian M; Moreira, Hannah A; Rodriguez, Luis; Mendelsohn, Alan L
2014-08-01
Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2-4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03-3.5) dose; associations greater for parents with low health literacy and non-English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon-associated measurement errors. Findings support a milliliter-only standard to reduce medication errors. Copyright © 2014 by the American Academy of Pediatrics.
Computer calculated dose in paediatric prescribing.
Kirk, Richard C; Li-Meng Goh, Denise; Packia, Jeya; Min Kam, Huey; Ong, Benjamin K C
2005-01-01
Medication errors are an important cause of hospital-based morbidity and mortality. However, only a few medication error studies have been conducted in children. These have mainly quantified errors in the inpatient setting; there is very little data available on paediatric outpatient and emergency department medication errors and none on discharge medication. This deficiency is of concern because medication errors are more common in children and it has been suggested that the risk of an adverse drug event as a consequence of a medication error is higher in children than in adults. The aims of this study were to assess the rate of medication errors in predominantly ambulatory paediatric patients and the effect of computer calculated doses on medication error rates of two commonly prescribed drugs. This was a prospective cohort study performed in a paediatric unit in a university teaching hospital between March 2003 and August 2003. The hospital's existing computer clinical decision support system was modified so that doctors could choose the traditional prescription method or the enhanced method of computer calculated dose when prescribing paracetamol (acetaminophen) or promethazine. All prescriptions issued to children (<16 years of age) at the outpatient clinic, emergency department and at discharge from the inpatient service were analysed. A medication error was defined as to have occurred if there was an underdose (below the agreed value), an overdose (above the agreed value), no frequency of administration specified, no dose given or excessive total daily dose. The medication error rates and the factors influencing medication error rates were determined using SPSS version 12. From March to August 2003, 4281 prescriptions were issued. Seven prescriptions (0.16%) were excluded, hence 4274 prescriptions were analysed. Most prescriptions were issued by paediatricians (including neonatologists and paediatric surgeons) and/or junior doctors. The error rate in the children's emergency department was 15.7%, for outpatients was 21.5% and for discharge medication was 23.6%. Most errors were the result of an underdose (64%; 536/833). The computer calculated dose error rate was 12.6% compared with the traditional prescription error rate of 28.2%. Logistical regression analysis showed that computer calculated dose was an important and independent variable influencing the error rate (adjusted relative risk = 0.436, 95% CI 0.336, 0.520, p < 0.001). Other important independent variables were seniority and paediatric training of the person prescribing and the type of drug prescribed. Medication error, especially underdose, is common in outpatient, emergency department and discharge prescriptions. Computer calculated doses can significantly reduce errors, but other risk factors have to be concurrently addressed to achieve maximum benefit.
Stevens, Allen D.; Hernandez, Caleb; Jones, Seth; Moreira, Maria E.; Blumen, Jason R.; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S.
2016-01-01
Background Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. Methods We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded-syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Results Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28–39) seconds and 42 (95% CI: 36–51) seconds, respectively (difference = 9 [95% CI: 4–14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference = 39%, 95% CI: 13–61%). Conclusions A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. PMID:26247145
Stevens, Allen D; Hernandez, Caleb; Jones, Seth; Moreira, Maria E; Blumen, Jason R; Hopkins, Emily; Sande, Margaret; Bakes, Katherine; Haukoos, Jason S
2015-11-01
Medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients where dosing often requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national healthcare priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared to conventional medication administration, in simulated prehospital pediatric resuscitation scenarios. We performed a prospective, block-randomized, cross-over study, where 10 full-time paramedics each managed two simulated pediatric arrests in situ using either prefilled, color-coded syringes (intervention) or their own medication kits stocked with conventional ampoules (control). Each paramedic was paired with two emergency medical technicians to provide ventilations and compressions as directed. The ambulance patient compartment and the intravenous medication port were video recorded. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the intervention and control groups was 34 (95% CI: 28-39) seconds and 42 (95% CI: 36-51) seconds, respectively (difference=9 [95% CI: 4-14] seconds). Using the conventional method, 62 doses were administered with 24 (39%) critical dosing errors; using the prefilled, color-coded syringe method, 59 doses were administered with 0 (0%) critical dosing errors (difference=39%, 95% CI: 13-61%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by paramedics during simulated prehospital pediatric resuscitations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Moreira, Maria E; Hernandez, Caleb; Stevens, Allen D; Jones, Seth; Sande, Margaret; Blumen, Jason R; Hopkins, Emily; Bakes, Katherine; Haukoos, Jason S
2015-08-01
The Institute of Medicine has called on the US health care system to identify and reduce medical errors. Unfortunately, medication dosing errors remain commonplace and may result in potentially life-threatening outcomes, particularly for pediatric patients when dosing requires weight-based calculations. Novel medication delivery systems that may reduce dosing errors resonate with national health care priorities. Our goal was to evaluate novel, prefilled medication syringes labeled with color-coded volumes corresponding to the weight-based dosing of the Broselow Tape, compared with conventional medication administration, in simulated pediatric emergency department (ED) resuscitation scenarios. We performed a prospective, block-randomized, crossover study in which 10 emergency physician and nurse teams managed 2 simulated pediatric arrest scenarios in situ, using either prefilled, color-coded syringes (intervention) or conventional drug administration methods (control). The ED resuscitation room and the intravenous medication port were video recorded during the simulations. Data were extracted from video review by blinded, independent reviewers. Median time to delivery of all doses for the conventional and color-coded delivery groups was 47 seconds (95% confidence interval [CI] 40 to 53 seconds) and 19 seconds (95% CI 18 to 20 seconds), respectively (difference=27 seconds; 95% CI 21 to 33 seconds). With the conventional method, 118 doses were administered, with 20 critical dosing errors (17%); with the color-coded method, 123 doses were administered, with 0 critical dosing errors (difference=17%; 95% CI 4% to 30%). A novel color-coded, prefilled syringe decreased time to medication administration and significantly reduced critical dosing errors by emergency physician and nurse teams during simulated pediatric ED resuscitations. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Al-Ramahi, Rowa'; Hmedat, Bayan; Alnjajrah, Eman; Manasrah, Israa; Radwan, Iqbal; Alkhatib, Maram
2017-09-01
Medication dosing errors are a significant global concern and can cause serious medical consequences for patients. Pediatric patients are at increased risk of dosing errors due to differences in medication pharmacodynamics and pharmacokinetics. The aims of this study were to find the rate of medication dosing errors in hospitalized pediatric patients and possible associated factors. The study was an observational cohort study including pediatric inpatients less than 16 years from three governmental hospitals from the West Bank/Palestine during one month in 2014, and sample size was 400 pediatric inpatients from these three hospitals. Pediatric patients' medical records were reviewed. Patients' weight, age, medical conditions, all prescribed medications, their doses and frequency were documented. Then the doses of medications were evaluated. Among 400 patients, the medications prescribed were 949 medications, 213 of them (22.4%) were out of the recommended range, and 160 patients (40.0%) were prescribed one or more potentially inappropriate doses. The most common cause of hospital admission was sepsis which presented 14.3% of cases, followed by fever (13.5%) and meningitis (10.0%). The most commonly used medications were ampicillin in 194 cases (20.4%), ceftriaxone in 182 cases (19.2%), and cefotaxime in 144 cases (12.0%). No significant association was found between potentially inappropriate doses and gender or hospital (chi-square test p -value > 0.05).The results showed that patients with lower body weight, who had a higher number of medications and stayed in hospital for a longer time, were more likely to have inappropriate doses. Potential medication dosing errors were high among pediatric hospitalized patients in Palestine. Younger patients, patients with lower body weight, who were prescribed higher number of medications and stayed in hospital for a longer time were more likely to have inappropriate doses, so these populations require special care. Many children were hospitalized for infectious causes and antibiotics were widely used. Strategies to reduce pediatric medication dosing errors are recommended.
Morales-González, María Fernanda; Galiano Gálvez, María Alejandra
2017-09-08
Our institution implemented the use of pre-designed labeling of intravenous drugs and fluids, administration routes and infusion pumps of to prevent medication errors. To evaluate the effectiveness of predesigned labeling in reducing medication errors in the preparation and administration stages of prescribed medication in patients hospitalized with invasive lines, and to characterize medication errors. This is a pre/post intervention study. Pre-intervention group: invasively administered dose from July 1st to December 31st, 2014, using traditional labeling (adhesive paper handwritten note). Post-intervention group: dose administered from January 1st to June 30th, 2015, using predesigned labeling (labeling with preset data-adhesive labels, color- grouped by drugs, labels with colors for invasive lines). Outcome: medication errors in hospitalized patients, as measured with notification form and record electronics. Tabulation/analysis Stata-10, with descriptive statistics, hypotheses testing, estimating risk with 95% confidence. In the pre-intervention group, 5,819 doses of drugs were administered invasively in 634 patients. Error rate of 1.4 x 1,000 administrations. The post-intervention group of 1088 doses comprised 8,585 patients with similar routes of administration. The error rate was 0.3 x 1,000 (p = 0.034). Patients receiving medication through an invasive route who did not use predesigned labeling had 4.6 times more risk of medication error than those who had used predesigned labels (95% CI: 1.25 to 25.4). The adult critically ill patient unit had the highest proportion of medication errors. The most frequent error was wrong dose administration. 41.2% produced harm to the patient. The use of predesigned labeling in invasive lines reduces errors in medication in the last two phases: preparation and administration.
Lane, Sandi J; Troyer, Jennifer L; Dienemann, Jacqueline A; Laditka, Sarah B; Blanchette, Christopher M
2014-01-01
Older adults are at greatest risk of medication errors during the transition period of the first 7 days after admission and readmission to a skilled nursing facility (SNF). The aim of this study was to evaluate structure- and process-related factors that contribute to medication errors and harm during transition periods at a SNF. Data for medication errors and potential medication errors during the 7-day transition period for residents entering North Carolina SNFs were from the Medication Error Quality Initiative-Individual Error database from October 2006 to September 2007. The impact of SNF structure and process measures on the number of reported medication errors and harm from errors were examined using bivariate and multivariate model methods. A total of 138 SNFs reported 581 transition period medication errors; 73 (12.6%) caused harm. Chain affiliation was associated with a reduction in the volume of errors during the transition period. One third of all reported transition errors occurred during the medication administration phase of the medication use process, where dose omissions were the most common type of error; however, dose omissions caused harm less often than wrong-dose errors did. Prescribing errors were much less common than administration errors but were much more likely to cause harm. Both structure and process measures of quality were related to the volume of medication errors.However, process quality measures may play a more important role in predicting harm from errors during the transition of a resident into an SNF. Medication errors during transition could be reduced by improving both prescribing processes and transcription and documentation of orders.
Liquid Medication Dosing Errors in Children: Role of Provider Counseling Strategies
Yin, H. Shonna; Dreyer, Benard P.; Moreira, Hannah A.; van Schaick, Linda; Rodriguez, Luis; Boettger, Susanne; Mendelsohn, Alan L.
2014-01-01
Objective To examine the degree to which recommended provider counseling strategies, including advanced communication techniques and dosing instrument provision, are associated with reductions in parent liquid medication dosing errors. Methods Cross-sectional analysis of baseline data on provider communication and dosing instrument provision from a study of a health literacy intervention to reduce medication errors. Parents whose children (<9 years) were seen in two urban public hospital pediatric emergency departments (EDs) and were prescribed daily dose liquid medications self-reported whether they received counseling about their child’s medication, including advanced strategies (teachback, drawings/pictures, demonstration, showback) and receipt of a dosing instrument. Primary dependent variable: observed dosing error (>20% deviation from prescribed). Multivariate logistic regression analyses performed, controlling for: parent age, language, country, ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease status; site. Results Of 287 parents, 41.1% made dosing errors. Advanced counseling and instrument provision in the ED were reported by 33.1% and 19.2%, respectively; 15.0% reported both. Advanced counseling and instrument provision in the ED were associated with decreased errors (30.5 vs. 46.4%, p=0.01; 21.8 vs. 45.7%, p=0.001). In adjusted analyses, ED advanced counseling in combination with instrument provision was associated with a decreased odds of error compared to receiving neither (AOR 0.3; 95% CI 0.1–0.7); advanced counseling alone and instrument alone were not significantly associated with odds of error. Conclusion Provider use of advanced counseling strategies and dosing instrument provision may be especially effective in reducing errors when used together. PMID:24767779
Liquid medication dosing errors in children: role of provider counseling strategies.
Yin, H Shonna; Dreyer, Benard P; Moreira, Hannah A; van Schaick, Linda; Rodriguez, Luis; Boettger, Susanne; Mendelsohn, Alan L
2014-01-01
To examine the degree to which recommended provider counseling strategies, including advanced communication techniques and dosing instrument provision, are associated with reductions in parent liquid medication dosing errors. Cross-sectional analysis of baseline data on provider communication and dosing instrument provision from a study of a health literacy intervention to reduce medication errors. Parents whose children (<9 years) were seen in 2 urban public hospital pediatric emergency departments (EDs) and were prescribed daily dose liquid medications self-reported whether they received counseling about their child's medication, including advanced strategies (teachback, drawings/pictures, demonstration, showback) and receipt of a dosing instrument. The primary dependent variable was observed dosing error (>20% deviation from prescribed). Multivariate logistic regression analyses were performed, controlling for parent age, language, country, ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease status; and site. Of 287 parents, 41.1% made dosing errors. Advanced counseling and instrument provision in the ED were reported by 33.1% and 19.2%, respectively; 15.0% reported both. Advanced counseling and instrument provision in the ED were associated with decreased errors (30.5 vs. 46.4%, P = .01; 21.8 vs. 45.7%, P = .001). In adjusted analyses, ED advanced counseling in combination with instrument provision was associated with a decreased odds of error compared to receiving neither (adjusted odds ratio 0.3; 95% confidence interval 0.1-0.7); advanced counseling alone and instrument alone were not significantly associated with odds of error. Provider use of advanced counseling strategies and dosing instrument provision may be especially effective in reducing errors when used together. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
[Detection and classification of medication errors at Joan XXIII University Hospital].
Jornet Montaña, S; Canadell Vilarrasa, L; Calabuig Mũoz, M; Riera Sendra, G; Vuelta Arce, M; Bardají Ruiz, A; Gallart Mora, M J
2004-01-01
Medication errors are multifactorial and multidisciplinary, and may originate in processes such as drug prescription, transcription, dispensation, preparation and administration. The goal of this work was to measure the incidence of detectable medication errors that arise within a unit dose drug distribution and control system, from drug prescription to drug administration, by means of an observational method confined to the Pharmacy Department, as well as a voluntary, anonymous report system. The acceptance of this voluntary report system's implementation was also assessed. A prospective descriptive study was conducted. Data collection was performed at the Pharmacy Department from a review of prescribed medical orders, a review of pharmaceutical transcriptions, a review of dispensed medication and a review of medication returned in unit dose medication carts. A voluntary, anonymous report system centralized in the Pharmacy Department was also set up to detect medication errors. Prescription errors were the most frequent (1.12%), closely followed by dispensation errors (1.04%). Transcription errors (0.42%) and administration errors (0.69%) had the lowest overall incidence. Voluntary report involved only 4.25% of all detected errors, whereas unit dose medication cart review contributed the most to error detection. Recognizing the incidence and types of medication errors that occur in a health-care setting allows us to analyze their causes and effect changes in different stages of the process in order to ensure maximal patient safety.
Liquid Medication Dosing Errors by Hispanic Parents: Role of Health Literacy and English Proficiency
Harris, Leslie M.; Dreyer, Benard; Mendelsohn, Alan; Bailey, Stacy C.; Sanders, Lee M.; Wolf, Michael S.; Parker, Ruth M.; Patel, Deesha A.; Kim, Kwang Youn A.; Jimenez, Jessica J.; Jacobson, Kara; Smith, Michelle; Yin, H. Shonna
2016-01-01
Objective Hispanic parents in the US are disproportionately affected by low health literacy and limited English proficiency (LEP). We examined associations between health literacy, LEP, and liquid medication dosing errors in Hispanic parents. Methods Cross-sectional analysis of data from a multisite randomized controlled experiment to identify best practices for the labeling/dosing of pediatric liquid medications (SAFE Rx for Kids study); 3 urban pediatric clinics. Analyses were limited to Hispanic parents of children <8 years, with health literacy and LEP data (n=1126). Parents were randomized to 5 groups that varied by pairing of units of measurement on the label/dosing tool. Each parent measured 9 doses [3 amounts (2.5,5,7.5 mL) using 3 tools (2 syringes (0.2,0.5 mL increment), 1 cup)] in random order. Dependent variable: Dosing error=>20% dose deviation. Predictor variables: health literacy (Newest Vital Sign) [limited=0–3; adequate=4–6], LEP (speaks English less than “very well”). Results 83.1% made dosing errors (mean(SD) errors/parent=2.2(1.9)). Parents with limited health literacy and LEP had the greatest odds of making a dosing error compared to parents with adequate health literacy who were English proficient (% trials with errors/parent=28.8 vs. 12.9%; AOR=2.2[1.7–2.8]). Parents with limited health literacy who were English proficient were also more likely to make errors (% trials with errors/parent=18.8%; AOR=1.4[1.1–1.9]). Conclusion Dosing errors are common among Hispanic parents; those with both LEP and limited health literacy are at particular risk. Further study is needed to examine how the redesign of medication labels and dosing tools could reduce literacy and language-associated disparities in dosing errors. PMID:28477800
Cost comparison of unit dose and traditional drug distribution in a long-term-care facility.
Lepinski, P W; Thielke, T S; Collins, D M; Hanson, A
1986-11-01
Unit dose and traditional drug distribution systems were compared in a 352-bed long-term-care facility by analyzing nursing time, medication-error rate, medication costs, and waste. Time spent by nurses in preparing, administering, charting, and other tasks associated with medications was measured with a stop-watch on four different nursing units during six-week periods before and after the nursing home began using unit dose drug distribution. Medication-error rate before and after implementation of the unit dose system was determined by patient profile audits and medication inventories. Medication costs consisted of patient billing costs (acquisition cost plus fee) and cost of medications destroyed. The unit dose system required a projected 1507.2 hours less nursing time per year. Mean medication-error rates were 8.53% and 0.97% for the traditional and unit dose systems, respectively. Potential annual savings because of decreased medication waste with the unit dose system were $2238.72. The net increase in cost for the unit dose system was estimated at $615.05 per year, or approximately $1.75 per patient. The unit dose system appears safer and more time-efficient than the traditional system, although its costs are higher.
Vogel, Erin A.; Billups, Sarah J.; Herner, Sheryl J.
2016-01-01
Summary Objective The purpose of this study was to compare the effectiveness of an outpatient renal dose adjustment alert via a computerized provider order entry (CPOE) clinical decision support system (CDSS) versus a CDSS with alerts made to dispensing pharmacists. Methods This was a retrospective analysis of patients with renal impairment and 30 medications that are contraindicated or require dose-adjustment in such patients. The primary outcome was the rate of renal dosing errors for study medications that were dispensed between August and December 2013, when a pharmacist-based CDSS was in place, versus August through December 2014, when a prescriber-based CDSS was in place. A dosing error was defined as a prescription for one of the study medications dispensed to a patient where the medication was contraindicated or improperly dosed based on the patient’s renal function. The denominator was all prescriptions for the study medications dispensed during each respective study period. Results During the pharmacist- and prescriber-based CDSS study periods, 49,054 and 50,678 prescriptions, respectively, were dispensed for one of the included medications. Of these, 878 (1.8%) and 758 (1.5%) prescriptions were dispensed to patients with renal impairment in the respective study periods. Patients in each group were similar with respect to age, sex, and renal function stage. Overall, the five-month error rate was 0.38%. Error rates were similar between the two groups: 0.36% and 0.40% in the pharmacist- and prescriber-based CDSS, respectively (p=0.523). The medication with the highest error rate was dofetilide (0.51% overall) while the medications with the lowest error rate were dabigatran, fondaparinux, and spironolactone (0.00% overall). Conclusions Prescriber- and pharmacist-based CDSS provided comparable, low rates of potential medication errors. Future studies should be undertaken to examine patient benefits of the prescriber-based CDSS. PMID:27466041
Davis, Stephen Jerome; Hurtado, Josephine; Nguyen, Rosemary; Huynh, Tran; Lindon, Ivan; Hudnall, Cedric; Bork, Sara
2017-01-01
Background: USP <797> regulatory requirements have mandated that pharmacies improve aseptic techniques and cleanliness of the medication preparation areas. In addition, the Institute for Safe Medication Practices (ISMP) recommends that technology and automation be used as much as possible for preparing and verifying compounded sterile products. Objective: To determine the benefits associated with the implementation of the workflow management system, such as reducing medication preparation and delivery errors, reducing quantity and frequency of medication errors, avoiding costs, and enhancing the organization's decision to move toward positive patient identification (PPID). Methods: At Texas Children's Hospital, data were collected and analyzed from January 2014 through August 2014 in the pharmacy areas in which the workflow management system would be implemented. Data were excluded for September 2014 during the workflow management system oral liquid implementation phase. Data were collected and analyzed from October 2014 through June 2015 to determine whether the implementation of the workflow management system reduced the quantity and frequency of reported medication errors. Data collected and analyzed during the study period included the quantity of doses prepared, number of incorrect medication scans, number of doses discontinued from the workflow management system queue, and the number of doses rejected. Data were collected and analyzed to identify patterns of incorrect medication scans, to determine reasons for rejected medication doses, and to determine the reduction in wasted medications. Results: During the 17-month study period, the pharmacy department dispensed 1,506,220 oral liquid and injectable medication doses. From October 2014 through June 2015, the pharmacy department dispensed 826,220 medication doses that were prepared and checked via the workflow management system. Of those 826,220 medication doses, there were 16 reported incorrect volume errors. The error rate after the implementation of the workflow management system averaged 8.4%, which was a 1.6% reduction. After the implementation of the workflow management system, the average number of reported oral liquid medication and injectable medication errors decreased to 0.4 and 0.2 times per week, respectively. Conclusion: The organization was able to achieve its purpose and goal of improving the provision of quality pharmacy care through optimal medication use and safety by reducing medication preparation errors. Error rates decreased and the workflow processes were streamlined, which has led to seamless operations within the pharmacy department. There has been significant cost avoidance and waste reduction and enhanced interdepartmental satisfaction due to the reduction of reported medication errors.
Pérez-Cebrián, M; Font-Noguera, I; Doménech-Moral, L; Bosó-Ribelles, V; Romero-Boyero, P; Poveda-Andrés, J L
2011-01-01
To assess the efficacy of a new quality control strategy based on daily randomised sampling and monitoring a Sentinel Surveillance System (SSS) medication cart, in order to identify medication errors and their origin at different levels of the process. Prospective quality control study with one year follow-up. A SSS medication cart was randomly selected once a week and double-checked before dispensing medication. Medication errors were recorded before it was taken to the relevant hospital ward. Information concerning complaints after receiving medication and 24-hour monitoring were also noted. Type and origin error data were assessed by a Unit Dose Quality Control Group, which proposed relevant improvement measures. Thirty-four SSS carts were assessed, including 5130 medication lines and 9952 dispensed doses, corresponding to 753 patients. Ninety erroneous lines (1.8%) and 142 mistaken doses (1.4%) were identified at the Pharmacy Department. The most frequent error was dose duplication (38%) and its main cause inappropriate management and forgetfulness (69%). Fifty medication complaints (6.6% of patients) were mainly due to new treatment at admission (52%), and 41 (0.8% of all medication lines), did not completely match the prescription (0.6% lines) as recorded by the Pharmacy Department. Thirty-seven (4.9% of patients) medication complaints due to changes at admission and 32 matching errors (0.6% medication lines) were recorded. The main cause also was inappropriate management and forgetfulness (24%). The simultaneous recording of incidences due to complaints and new medication coincided in 33.3%. In addition, 433 (4.3%) of dispensed doses were returned to the Pharmacy Department. After the Unit Dose Quality Control Group conducted their feedback analysis, 64 improvement measures for Pharmacy Department nurses, 37 for pharmacists, and 24 for the hospital ward were introduced. The SSS programme has proven to be useful as a quality control strategy to identify Unit Dose Distribution System errors at initial, intermediate and final stages of the process, improving the involvement of the Pharmacy Department and ward nurses. Copyright © 2009 SEFH. Published by Elsevier Espana. All rights reserved.
Ching, Joan M; Williams, Barbara L; Idemoto, Lori M; Blackmore, C Craig
2014-08-01
Virginia Mason Medical Center (Seattle) employed the Lean concept of Jidoka (automation with a human touch) to plan for and deploy bar code medication administration (BCMA) to hospitalized patients. Integrating BCMA technology into the nursing work flow with minimal disruption was accomplished using three steps ofJidoka: (1) assigning work to humans and machines on the basis of their differing abilities, (2) adapting machines to the human work flow, and (3) monitoring the human-machine interaction. Effectiveness of BCMA to both reinforce safe administration practices and reduce medication errors was measured using the Collaborative Alliance for Nursing Outcomes (CALNOC) Medication Administration Accuracy Quality Study methodology. Trained nurses observed a total of 16,149 medication doses for 3,617 patients in a three-year period. Following BCMA implementation, the number of safe practice violations decreased from 54.8 violations/100 doses (January 2010-September 2011) to 29.0 violations/100 doses (October 2011-December 2012), resulting in an absolute risk reduction of 25.8 violations/100 doses (95% confidence interval [CI]: 23.7, 27.9, p < .001). The number of medication errors decreased from 5.9 errors/100 doses at baseline to 3.0 errors/100 doses after BCMA implementation (absolute risk reduction: 2.9 errors/100 doses [95% CI: 2.2, 3.6,p < .001]). The number of unsafe administration practices (estimate, -5.481; standard error 1.133; p < .001; 95% CI: -7.702, -3.260) also decreased. As more hospitals respond to health information technology meaningful use incentives, thoughtful, methodical, and well-managed approaches to technology deployment are crucial. This work illustrates how Jidoka offers opportunities for a smooth transition to new technology.
Bledsoe, Sarah; Van Buskirk, Alex; Falconer, R James; Hollon, Andrew; Hoebing, Wendy; Jokic, Sladan
2018-02-01
The effectiveness of barcode-assisted medication preparation (BCMP) technology on detecting oral liquid dose preparation errors. From June 1, 2013, through May 31, 2014, a total of 178,344 oral doses were processed at Children's Mercy, a 301-bed pediatric hospital, through an automated workflow management system. Doses containing errors detected by the system's barcode scanning system or classified as rejected by the pharmacist were further reviewed. Errors intercepted by the barcode-scanning system were classified as (1) expired product, (2) incorrect drug, (3) incorrect concentration, and (4) technological error. Pharmacist-rejected doses were categorized into 6 categories based on the root cause of the preparation error: (1) expired product, (2) incorrect concentration, (3) incorrect drug, (4) incorrect volume, (5) preparation error, and (6) other. Of the 178,344 doses examined, 3,812 (2.1%) errors were detected by either the barcode-assisted scanning system (1.8%, n = 3,291) or a pharmacist (0.3%, n = 521). The 3,291 errors prevented by the barcode-assisted system were classified most commonly as technological error and incorrect drug, followed by incorrect concentration and expired product. Errors detected by pharmacists were also analyzed. These 521 errors were most often classified as incorrect volume, preparation error, expired product, other, incorrect drug, and incorrect concentration. BCMP technology detected errors in 1.8% of pediatric oral liquid medication doses prepared in an automated workflow management system, with errors being most commonly attributed to technological problems or incorrect drugs. Pharmacists rejected an additional 0.3% of studied doses. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Gilmartin-Thomas, Julia Fiona-Maree; Smith, Felicity; Wolfe, Rory; Jani, Yogini
2017-07-01
No published study has been specifically designed to compare medication administration errors between original medication packaging and multi-compartment compliance aids in care homes, using direct observation. Compare the effect of original medication packaging and multi-compartment compliance aids on medication administration accuracy. Prospective observational. Ten Greater London care homes. Nurses and carers administering medications. Between October 2014 and June 2015, a pharmacist researcher directly observed solid, orally administered medications in tablet or capsule form at ten purposively sampled care homes (five only used original medication packaging and five used both multi-compartment compliance aids and original medication packaging). The medication administration error rate was calculated as the number of observed doses administered (or omitted) in error according to medication administration records, compared to the opportunities for error (total number of observed doses plus omitted doses). Over 108.4h, 41 different staff (35 nurses, 6 carers) were observed to administer medications to 823 residents during 90 medication administration rounds. A total of 2452 medication doses were observed (1385 from original medication packaging, 1067 from multi-compartment compliance aids). One hundred and seventy eight medication administration errors were identified from 2493 opportunities for error (7.1% overall medication administration error rate). A greater medication administration error rate was seen for original medication packaging than multi-compartment compliance aids (9.3% and 3.1% respectively, risk ratio (RR)=3.9, 95% confidence interval (CI) 2.4 to 6.1, p<0.001). Similar differences existed when comparing medication administration error rates between original medication packaging (from original medication packaging-only care homes) and multi-compartment compliance aids (RR=2.3, 95%CI 1.1 to 4.9, p=0.03), and between original medication packaging and multi-compartment compliance aids within care homes that used a combination of both medication administration systems (RR=4.3, 95%CI 2.7 to 6.8, p<0.001). A significant difference in error rate was not observed between use of a single or combination medication administration system (p=0.44). The significant difference in, and high overall, medication administration error rate between original medication packaging and multi-compartment compliance aids supports the use of the latter in care homes, as well as local investigation of tablet and capsule impact on medication administration errors and staff training to prevent errors occurring. As a significant difference in error rate was not observed between use of a single or combination medication administration system, common practice of using both multi-compartment compliance aids (for most medications) and original packaging (for medications with stability issues) is supported. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cassidy, Nicola; Duggan, Edel; Williams, David J P; Tracey, Joseph A
2011-07-01
Medication errors are widely reported for hospitalised patients, but limited data are available for medication errors that occur in community-based and clinical settings. Epidemiological data from poisons information centres enable characterisation of trends in medication errors occurring across the healthcare spectrum. The objective of this study was to characterise the epidemiology and type of medication errors reported to the National Poisons Information Centre (NPIC) of Ireland. A 3-year prospective study on medication errors reported to the NPIC was conducted from 1 January 2007 to 31 December 2009 inclusive. Data on patient demographics, enquiry source, location, pharmaceutical agent(s), type of medication error, and treatment advice were collated from standardised call report forms. Medication errors were categorised as (i) prescribing error (i.e. physician error), (ii) dispensing error (i.e. pharmacy error), and (iii) administration error involving the wrong medication, the wrong dose, wrong route, or the wrong time. Medication errors were reported for 2348 individuals, representing 9.56% of total enquiries to the NPIC over 3 years. In total, 1220 children and adolescents under 18 years of age and 1128 adults (≥ 18 years old) experienced a medication error. The majority of enquiries were received from healthcare professionals, but members of the public accounted for 31.3% (n = 736) of enquiries. Most medication errors occurred in a domestic setting (n = 2135), but a small number occurred in healthcare facilities: nursing homes (n = 110, 4.68%), hospitals (n = 53, 2.26%), and general practitioner surgeries (n = 32, 1.36%). In children, medication errors with non-prescription pharmaceuticals predominated (n = 722) and anti-pyretics and non-opioid analgesics, anti-bacterials, and cough and cold preparations were the main pharmaceutical classes involved. Medication errors with prescription medication predominated for adults (n = 866) and the major medication classes included anti-pyretics and non-opioid analgesics, psychoanaleptics, and psychleptic agents. Approximately 97% (n = 2279) of medication errors were as a result of drug administration errors (comprising a double dose [n = 1040], wrong dose [n = 395], wrong medication [n = 597], wrong route [n = 133], and wrong time [n = 110]). Prescribing and dispensing errors accounted for 0.68% (n = 16) and 2.26% (n = 53) of errors, respectively. Empirical data from poisons information centres facilitate the characterisation of medication errors occurring in the community and across the healthcare spectrum. Poison centre data facilitate the detection of subtle trends in medication errors and can contribute to pharmacovigilance. Collaboration between pharmaceutical manufacturers, consumers, medical, and regulatory communities is needed to advance patient safety and reduce medication errors.
Ryu, Gyeong Suk; Lee, Yu Jeung
2012-01-01
Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4.660 mL for the dosing spoon (n = 10; P < 0.001). Doses were within 10% of the 5 mL target volume for 88.7% (n = 266) of the participant samples. Only 34 cases (11.3%) had dose errors greater than 10%, and only 6 cases (2.0%) had a variance of more than 20% from the 5 mL target volume. Dose errors greater than 10% of the target volume were more common for the etched dosing cup (47.1%, n = 8), the dosing spoon (50.0%, n = 5), and the printed dosing cup (30.8%, n = 4), but these 3 devices were used by only 13.3% of the study participants. Approximately 1 in 10 participants measured doses of liquid medication with a volume error greater than 10%, and these dose errors were more common with the etched dosing cup, the dosing spoon, and the printed dosing cup. Pharmacists have an opportunity to counsel patients or caregivers regarding the appropriate use of measuring devices for liquid medication.
Medication safety initiative in reducing medication errors.
Nguyen, Elisa E; Connolly, Phyllis M; Wong, Vivian
2010-01-01
The purpose of the study was to evaluate whether a Medication Pass Time Out initiative was effective and sustainable in reducing medication administration errors. A retrospective descriptive method was used for this research, where a structured Medication Pass Time Out program was implemented following staff and physician education. As a result, the rate of interruptions during the medication administration process decreased from 81% to 0. From the observations at baseline, 6 months, and 1 year after implementation, the percent of doses of medication administered without interruption improved from 81% to 99%. Medication doses administered without errors at baseline, 6 months, and 1 year improved from 98% to 100%.
Elimination of Emergency Department Medication Errors Due To Estimated Weights.
Greenwalt, Mary; Griffen, David; Wilkerson, Jim
2017-01-01
From 7/2014 through 6/2015, 10 emergency department (ED) medication dosing errors were reported through the electronic incident reporting system of an urban academic medical center. Analysis of these medication errors identified inaccurate estimated weight on patients as the root cause. The goal of this project was to reduce weight-based dosing medication errors due to inaccurate estimated weights on patients presenting to the ED. Chart review revealed that 13.8% of estimated weights documented on admitted ED patients varied more than 10% from subsequent actual admission weights recorded. A random sample of 100 charts containing estimated weights revealed 2 previously unreported significant medication dosage errors (.02 significant error rate). Key improvements included removing barriers to weighing ED patients, storytelling to engage staff and change culture, and removal of the estimated weight documentation field from the ED electronic health record (EHR) forms. With these improvements estimated weights on ED patients, and the resulting medication errors, were eliminated.
Medication Incidents Involving Antiepileptic Drugs in Canadian Hospitals: A Multi-Incident Analysis.
Cheng, Roger; Yang, Yu Daisy; Chan, Matthew; Patel, Tejal
2017-01-01
Medication errors involving antiepileptic drugs (AEDs) are not well studied but have the potential to cause significant harm. We investigated the occurrence of medication incidents in Canadian hospitals that involve AEDs, their severity and contributing factors by analyzing data from two national databases. Our multi-incident analysis revealed that while medication errors were rarely fatal, errors do occur of which some are serious. Medication incidents were most commonly caused by dose omissions, the dose or its frequency being incorrect and the wrong AED being given. Our analysis could augment quality-improvement initiatives by medication safety administrators to reduce AED medication incidents in hospitals.
Sethuraman, Usha; Kannikeswaran, Nirupama; Murray, Kyle P; Zidan, Marwan A; Chamberlain, James M
2015-06-01
Prescription errors occur frequently in pediatric emergency departments (PEDs).The effect of computerized physician order entry (CPOE) with electronic medication alert system (EMAS) on these is unknown. The objective was to compare prescription errors rates before and after introduction of CPOE with EMAS in a PED. The hypothesis was that CPOE with EMAS would significantly reduce the rate and severity of prescription errors in the PED. A prospective comparison of a sample of outpatient, medication prescriptions 5 months before and after CPOE with EMAS implementation (7,268 before and 7,292 after) was performed. Error types and rates, alert types and significance, and physician response were noted. Medication errors were deemed significant if there was a potential to cause life-threatening injury, failure of therapy, or an adverse drug effect. There was a significant reduction in the errors per 100 prescriptions (10.4 before vs. 7.3 after; absolute risk reduction = 3.1, 95% confidence interval [CI] = 2.2 to 4.0). Drug dosing error rates decreased from 8 to 5.4 per 100 (absolute risk reduction = 2.6, 95% CI = 1.8 to 3.4). Alerts were generated for 29.6% of prescriptions, with 45% involving drug dose range checking. The sensitivity of CPOE with EMAS in identifying errors in prescriptions was 45.1% (95% CI = 40.8% to 49.6%), and the specificity was 57% (95% CI = 55.6% to 58.5%). Prescribers modified 20% of the dosing alerts, resulting in the error not reaching the patient. Conversely, 11% of true dosing alerts for medication errors were overridden by the prescribers: 88 (11.3%) resulted in medication errors, and 684 (88.6%) were false-positive alerts. A CPOE with EMAS was associated with a decrease in overall prescription errors in our PED. Further system refinements are required to reduce the high false-positive alert rates. © 2015 by the Society for Academic Emergency Medicine.
Methodological Challenges in Describing Medication Dosing Errors in Children
2005-01-01
recommendations. As an example, amoxicillin is the most commonly used medication in children. This one drug accounts for approximately 10 percent of...and a team intervention on prevention of serious medication errors. JAMA 1998;280(15):1311–6. 13. Bates DW, Teich JM, Lee J, et al. The impact of...barriers include prescribing medication that is not labeled for use in children, discrepancies in published dosing recommendations for many
Medication errors in anesthesia: unacceptable or unavoidable?
Dhawan, Ira; Tewari, Anurag; Sehgal, Sankalp; Sinha, Ashish Chandra
Medication errors are the common causes of patient morbidity and mortality. It adds financial burden to the institution as well. Though the impact varies from no harm to serious adverse effects including death, it needs attention on priority basis since medication errors' are preventable. In today's world where people are aware and medical claims are on the hike, it is of utmost priority that we curb this issue. Individual effort to decrease medication error alone might not be successful until a change in the existing protocols and system is incorporated. Often drug errors that occur cannot be reversed. The best way to 'treat' drug errors is to prevent them. Wrong medication (due to syringe swap), overdose (due to misunderstanding or preconception of the dose, pump misuse and dilution error), incorrect administration route, under dosing and omission are common causes of medication error that occur perioperatively. Drug omission and calculation mistakes occur commonly in ICU. Medication errors can occur perioperatively either during preparation, administration or record keeping. Numerous human and system errors can be blamed for occurrence of medication errors. The need of the hour is to stop the blame - game, accept mistakes and develop a safe and 'just' culture in order to prevent medication errors. The newly devised systems like VEINROM, a fluid delivery system is a novel approach in preventing drug errors due to most commonly used medications in anesthesia. Similar developments along with vigilant doctors, safe workplace culture and organizational support all together can help prevent these errors. Copyright © 2016. Published by Elsevier Editora Ltda.
Comprehensive analysis of a medication dosing error related to CPOE.
Horsky, Jan; Kuperman, Gilad J; Patel, Vimla L
2005-01-01
This case study of a serious medication error demonstrates the necessity of a comprehensive methodology for the analysis of failures in interaction between humans and information systems. The authors used a novel approach to analyze a dosing error related to computer-based ordering of potassium chloride (KCl). The method included a chronological reconstruction of events and their interdependencies from provider order entry usage logs, semistructured interviews with involved clinicians, and interface usability inspection of the ordering system. Information collected from all sources was compared and evaluated to understand how the error evolved and propagated through the system. In this case, the error was the product of faults in interaction among human and system agents that methods limited in scope to their distinct analytical domains would not identify. The authors characterized errors in several converging aspects of the drug ordering process: confusing on-screen laboratory results review, system usability difficulties, user training problems, and suboptimal clinical system safeguards that all contributed to a serious dosing error. The results of the authors' analysis were used to formulate specific recommendations for interface layout and functionality modifications, suggest new user alerts, propose changes to user training, and address error-prone steps of the KCl ordering process to reduce the risk of future medication dosing errors.
Zeraatchi, Alireza; Talebian, Mohammad-Taghi; Nejati, Amir; Dashti-Khavidaki, Simin
2013-07-01
Emergency departments (EDs) are characterized by simultaneous care of multiple patients with various medical conditions. Due to a large number of patients with complex diseases, speed and complexity of medication use, working in under-staffing and crowded environment, medication errors are commonly perpetrated by emergency care providers. This study was designed to evaluate the incidence of medication errors among patients attending to an ED in a teaching hospital in Iran. In this cross-sectional study, a total of 500 patients attending to ED were randomly assessed for incidence and types of medication errors. Some factors related to medication errors such as working shift, weekdays and schedule of the educational program of trainee were also evaluated. Nearly, 22% of patients experienced at least one medication error. The rate of medication errors were 0.41 errors per patient and 0.16 errors per ordered medication. The frequency of medication errors was higher in men, middle age patients, first weekdays, night-time work schedules and the first semester of educational year of new junior emergency medicine residents. More than 60% of errors were prescription errors by physicians and the remaining were transcription or administration errors by nurses. More than 35% of the prescribing errors happened during the selection of drug dose and frequency. The most common medication errors by nurses during the administration were omission error (16.2%) followed by unauthorized drug (6.4%). Most of the medication errors happened for anticoagulants and thrombolytics (41.2%) followed by antimicrobial agents (37.7%) and insulin (7.4%). In this study, at least one-fifth of the patients attending to ED experienced medication errors resulting from multiple factors. More common prescription errors happened during ordering drug dose and frequency. More common administration errors included dug omission or unauthorized drug.
Sadasivam, Rajani S; Gathibandhe, Vaibhav; Tanik, Murat M; Willig, James H
2012-06-01
Medication dosing errors can greatly reduce HIV treatment effectiveness as incorrect dosing leads to drug resistance and non-adherence. In order to dose correctly, HIV therapy providers must balance several patient characteristics such as renal functions and weight. In developing countries and other resource-limited settings, dosing errors are more likely because treatment is provided by mid-level providers with only basic training in HIV therapy. These providers also typically lack electronic tools informing medical decisions. Widespread adoption of mobile phones in developing nations offers an opportunity to implement a point-of-care system to help providers reduce dosing errors. We discuss the development of the mHIV-Dr system prototype using the new Android mobile platform. mHIV-Dr is being designed to provide dosing recommendations for front-line providers in developing countries. We also discuss the additional challenges in the implementation of the mHIV-Dr system in a resource limited setting.
Insel, Catherine; Reinen, Jenna; Weber, Jochen; Wager, Tor D; Jarskog, L Fredrik; Shohamy, Daphna; Smith, Edward E
2014-03-01
Schizophrenia is characterized by an abnormal dopamine system, and dopamine blockade is the primary mechanism of antipsychotic treatment. Consistent with the known role of dopamine in reward processing, prior research has demonstrated that patients with schizophrenia exhibit impairments in reward-based learning. However, it remains unknown how treatment with antipsychotic medication impacts the behavioral and neural signatures of reinforcement learning in schizophrenia. The goal of this study was to examine whether antipsychotic medication modulates behavioral and neural responses to prediction error coding during reinforcement learning. Patients with schizophrenia completed a reinforcement learning task while undergoing functional magnetic resonance imaging. The task consisted of two separate conditions in which participants accumulated monetary gain or avoided monetary loss. Behavioral results indicated that antipsychotic medication dose was associated with altered behavioral approaches to learning, such that patients taking higher doses of medication showed increased sensitivity to negative reinforcement. Higher doses of antipsychotic medication were also associated with higher learning rates (LRs), suggesting that medication enhanced sensitivity to trial-by-trial feedback. Neuroimaging data demonstrated that antipsychotic dose was related to differences in neural signatures of feedback prediction error during the loss condition. Specifically, patients taking higher doses of medication showed attenuated prediction error responses in the striatum and the medial prefrontal cortex. These findings indicate that antipsychotic medication treatment may influence motivational processes in patients with schizophrenia.
Kaufmann, Jost; Roth, Bernhard; Engelhardt, Thomas; Lechleuthner, Alex; Laschat, Michael; Hadamitzky, Christoph; Wappler, Frank; Hellmich, Martin
2018-01-01
Drug dosing errors pose a particular threat to children in prehospital emergency care. With the Pediatric emergency ruler (PaedER), we developed a simple height-based dose recommendation system and evaluated its effectiveness in a pre-post interventional trial as the Ethics Committee disapproved randomization due to the expected positive effect of the PaedER on outcome. Pre-interventional data were retrospectively retrieved from the electronic records and medical protocols of the Cologne Emergency Medical Service over a two-year period prior to the introduction of the PaedER. Post-interventional data were collected prospectively over a six-year period in a federal state-wide open trial. The administered doses of either intravenous or intraosseous fentanyl, midazolam, ketamine or epinephrine were recorded. Primary outcome measure was the number and severity of drug dose deviation from recommended dose (DRD) based on the patient's weight. Fifty-nine pre-interventional and 91 post-interventional prehospital drug administrations in children were analyzed. The rate of DRD > 300% overall medications were 22.0% in the pre- and 2.2% in the post-interventional group (p < 0.001). All administrations of epinephrine occurred excessive (DRD > 300%) in pre-interventional and none in post-interventional patients (p < 0.001). The use of the PaedER resulted in a 90% reduction of medication errors (95% CI: 57% to 98%; p < 0.001) and prevented all potentially life-threatening errors associated with epinephrine administration. There is an urgent need to increase the safety of emergency drug dosing in children during emergencies. A simple height-based system can support health care providers and helps to avoid life-threatening medication errors.
Yousef, Nadin; Yousef, Farah
2017-09-04
Whereas one of the predominant causes of medication errors is a drug administration error, a previous study related to our investigations and reviews estimated that the incidences of medication errors constituted 6.7 out of 100 administrated medication doses. Therefore, we aimed by using six sigma approach to propose a way that reduces these errors to become less than 1 out of 100 administrated medication doses by improving healthcare professional education and clearer handwritten prescriptions. The study was held in a General Government Hospital. First, we systematically studied the current medication use process. Second, we used six sigma approach by utilizing the five-step DMAIC process (Define, Measure, Analyze, Implement, Control) to find out the real reasons behind such errors. This was to figure out a useful solution to avoid medication error incidences in daily healthcare professional practice. Data sheet was used in Data tool and Pareto diagrams were used in Analyzing tool. In our investigation, we reached out the real cause behind administrated medication errors. As Pareto diagrams used in our study showed that the fault percentage in administrated phase was 24.8%, while the percentage of errors related to prescribing phase was 42.8%, 1.7 folds. This means that the mistakes in prescribing phase, especially because of the poor handwritten prescriptions whose percentage in this phase was 17.6%, are responsible for the consequent) mistakes in this treatment process later on. Therefore, we proposed in this study an effective low cost strategy based on the behavior of healthcare workers as Guideline Recommendations to be followed by the physicians. This method can be a prior caution to decrease errors in prescribing phase which may lead to decrease the administrated medication error incidences to less than 1%. This improvement way of behavior can be efficient to improve hand written prescriptions and decrease the consequent errors related to administrated medication doses to less than the global standard; as a result, it enhances patient safety. However, we hope other studies will be made later in hospitals to practically evaluate how much effective our proposed systematic strategy really is in comparison with other suggested remedies in this field.
Medication Administration Practices of School Nurses.
ERIC Educational Resources Information Center
McCarthy, Ann Marie; Kelly, Michael W.; Reed, David
2000-01-01
Assessed medication administration practices among school nurses, surveying members of the National Association of School Nurses. Respondents were extremely concerned about medication administration. Errors in administering medications were reported by 48.5 percent of respondents, with missed doses the most common error. Most nurses followed…
Terkola, R; Czejka, M; Bérubé, J
2017-08-01
Medication errors are a significant cause of morbidity and mortality especially with antineoplastic drugs, owing to their narrow therapeutic index. Gravimetric workflow software systems have the potential to reduce volumetric errors during intravenous antineoplastic drug preparation which may occur when verification is reliant on visual inspection. Our aim was to detect medication errors with possible critical therapeutic impact as determined by the rate of prevented medication errors in chemotherapy compounding after implementation of gravimetric measurement. A large-scale, retrospective analysis of data was carried out, related to medication errors identified during preparation of antineoplastic drugs in 10 pharmacy services ("centres") in five European countries following the introduction of an intravenous workflow software gravimetric system. Errors were defined as errors in dose volumes outside tolerance levels, identified during weighing stages of preparation of chemotherapy solutions which would not otherwise have been detected by conventional visual inspection. The gravimetric system detected that 7.89% of the 759 060 doses of antineoplastic drugs prepared at participating centres between July 2011 and October 2015 had error levels outside the accepted tolerance range set by individual centres, and prevented these doses from reaching patients. The proportion of antineoplastic preparations with deviations >10% ranged from 0.49% to 5.04% across sites, with a mean of 2.25%. The proportion of preparations with deviations >20% ranged from 0.21% to 1.27% across sites, with a mean of 0.71%. There was considerable variation in error levels for different antineoplastic agents. Introduction of a gravimetric preparation system for antineoplastic agents detected and prevented dosing errors which would not have been recognized with traditional methods and could have resulted in toxicity or suboptimal therapeutic outcomes for patients undergoing anticancer treatment. © 2017 The Authors. Journal of Clinical Pharmacy and Therapeutics Published by John Wiley & Sons Ltd.
Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L
2011-02-01
Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes must be continually analyzed and restructured to yield the intended full benefits of BCMA technology. © 2011 SAGE Publications.
Urban, Michal; Leššo, Roman; Pelclová, Daniela
2016-07-01
The purpose of the article was to study unintentional pharmaceutical-related poisonings committed by laypersons that were reported to the Toxicological Information Centre in the Czech Republic. Identifying frequency, sources, reasons and consequences of the medication errors in laypersons could help to reduce the overall rate of medication errors. Records of medication error enquiries from 2013 to 2014 were extracted from the electronic database, and the following variables were reviewed: drug class, dosage form, dose, age of the subject, cause of the error, time interval from ingestion to the call, symptoms, prognosis at the time of the call and first aid recommended. Of the calls, 1354 met the inclusion criteria. Among them, central nervous system-affecting drugs (23.6%), respiratory drugs (18.5%) and alimentary drugs (16.2%) were the most common drug classes involved in the medication errors. The highest proportion of the patients was in the youngest age subgroup 0-5 year-old (46%). The reasons for the medication errors involved the leaflet misinterpretation and mistaken dose (53.6%), mixing up medications (19.2%), attempting to reduce pain with repeated doses (6.4%), erroneous routes of administration (2.2%), psychiatric/elderly patients (2.7%), others (9.0%) or unknown (6.9%). A high proportion of children among the patients may be due to the fact that children's dosages for many drugs vary by their weight, and more medications come in a variety of concentrations. Most overdoses could be prevented by safer labelling, proper cap closure systems for liquid products and medication reconciliation by both physicians and pharmacists. © 2016 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).
Analyzing temozolomide medication errors: potentially fatal.
Letarte, Nathalie; Gabay, Michael P; Bressler, Linda R; Long, Katie E; Stachnik, Joan M; Villano, J Lee
2014-10-01
The EORTC-NCIC regimen for glioblastoma requires different dosing of temozolomide (TMZ) during radiation and maintenance therapy. This complexity is exacerbated by the availability of multiple TMZ capsule strengths. TMZ is an alkylating agent and the major toxicity of this class is dose-related myelosuppression. Inadvertent overdose can be fatal. The websites of the Institute for Safe Medication Practices (ISMP), and the Food and Drug Administration (FDA) MedWatch database were reviewed. We searched the MedWatch database for adverse events associated with TMZ and obtained all reports including hematologic toxicity submitted from 1st November 1997 to 30th May 2012. The ISMP describes errors with TMZ resulting from the positioning of information on the label of the commercial product. The strength and quantity of capsules on the label were in close proximity to each other, and this has been changed by the manufacturer. MedWatch identified 45 medication errors. Patient errors were the most common, accounting for 21 or 47% of errors, followed by dispensing errors, which accounted for 13 or 29%. Seven reports or 16% were errors in the prescribing of TMZ. Reported outcomes ranged from reversible hematological adverse events (13%), to hospitalization for other adverse events (13%) or death (18%). Four error reports lacked detail and could not be categorized. Although the FDA issued a warning in 2003 regarding fatal medication errors and the product label warns of overdosing, errors in TMZ dosing occur for various reasons and involve both healthcare professionals and patients. Overdosing errors can be fatal.
Alsulami, Zayed; Choonara, Imti; Conroy, Sharon
2014-06-01
To evaluate how closely double-checking policies are followed by nurses in paediatric areas and also to identify the types, frequency and rates of medication administration errors that occur despite the double-checking process. Double-checking by two nurses is an intervention used in many UK hospitals to prevent or reduce medication administration errors. There is, however, insufficient evidence to either support or refute the practice of double-checking in terms of medication error risk reduction. Prospective observational study. This was a prospective observational study of paediatric nurses' adherence to the double-checking process for medication administration from April-July 2012. Drug dose administration events (n = 2000) were observed. Independent drug dose calculation, rate of administering intravenous bolus drugs and labelling of flush syringes were the steps with lowest adherence rates. Drug dose calculation was only double-checked independently in 591 (30%) drug administrations. There was a statistically significant difference in nurses' adherence rate to the double-checking steps between weekdays and weekends in nine of the 15 evaluated steps. Medication administration errors (n = 191) or deviations from policy were observed, at a rate of 9·6% of drug administrations. These included 64 drug doses, which were left for parents to administer without nurse observation. There was variation between paediatric nurses' adherence to double-checking steps during medication administration. The most frequent type of administration errors or deviation from policy involved the medicine being given to the parents to administer to the child when the nurse was not present. © 2013 John Wiley & Sons Ltd.
Medication Errors in Vietnamese Hospitals: Prevalence, Potential Outcome and Associated Factors
Nguyen, Huong-Thao; Nguyen, Tuan-Dung; van den Heuvel, Edwin R.; Haaijer-Ruskamp, Flora M.; Taxis, Katja
2015-01-01
Background Evidence from developed countries showed that medication errors are common and harmful. Little is known about medication errors in resource-restricted settings, including Vietnam. Objectives To determine the prevalence and potential clinical outcome of medication preparation and administration errors, and to identify factors associated with errors. Methods This was a prospective study conducted on six wards in two urban public hospitals in Vietnam. Data of preparation and administration errors of oral and intravenous medications was collected by direct observation, 12 hours per day on 7 consecutive days, on each ward. Multivariable logistic regression was applied to identify factors contributing to errors. Results In total, 2060 out of 5271 doses had at least one error. The error rate was 39.1% (95% confidence interval 37.8%- 40.4%). Experts judged potential clinical outcomes as minor, moderate, and severe in 72 (1.4%), 1806 (34.2%) and 182 (3.5%) doses. Factors associated with errors were drug characteristics (administration route, complexity of preparation, drug class; all p values < 0.001), and administration time (drug round, p = 0.023; day of the week, p = 0.024). Several interactions between these factors were also significant. Nurse experience was not significant. Higher error rates were observed for intravenous medications involving complex preparation procedures and for anti-infective drugs. Slightly lower medication error rates were observed during afternoon rounds compared to other rounds. Conclusions Potentially clinically relevant errors occurred in more than a third of all medications in this large study conducted in a resource-restricted setting. Educational interventions, focusing on intravenous medications with complex preparation procedure, particularly antibiotics, are likely to improve patient safety. PMID:26383873
Lobaugh, Lauren M Y; Martin, Lizabeth D; Schleelein, Laura E; Tyler, Donald C; Litman, Ronald S
2017-09-01
Wake Up Safe is a quality improvement initiative of the Society for Pediatric Anesthesia that contains a deidentified registry of serious adverse events occurring in pediatric anesthesia. The aim of this study was to describe and characterize reported medication errors to find common patterns amenable to preventative strategies. In September 2016, we analyzed approximately 6 years' worth of medication error events reported to Wake Up Safe. Medication errors were classified by: (1) medication category; (2) error type by phase of administration: prescribing, preparation, or administration; (3) bolus or infusion error; (4) provider type and level of training; (5) harm as defined by the National Coordinating Council for Medication Error Reporting and Prevention; and (6) perceived preventability. From 2010 to the time of our data analysis in September 2016, 32 institutions had joined and submitted data on 2087 adverse events during 2,316,635 anesthetics. These reports contained details of 276 medication errors, which comprised the third highest category of events behind cardiac and respiratory related events. Medication errors most commonly involved opioids and sedative/hypnotics. When categorized by phase of handling, 30 events occurred during preparation, 67 during prescribing, and 179 during administration. The most common error type was accidental administration of the wrong dose (N = 84), followed by syringe swap (accidental administration of the wrong syringe, N = 49). Fifty-seven (21%) reported medication errors involved medications prepared as infusions as opposed to 1 time bolus administrations. Medication errors were committed by all types of anesthesia providers, most commonly by attendings. Over 80% of reported medication errors reached the patient and more than half of these events caused patient harm. Fifteen events (5%) required a life sustaining intervention. Nearly all cases (97%) were judged to be either likely or certainly preventable. Our findings characterize the most common types of medication errors in pediatric anesthesia practice and provide guidance on future preventative strategies. Many of these errors will be almost entirely preventable with the use of prefilled medication syringes to avoid accidental ampule swap, bar-coding at the point of medication administration to prevent syringe swap and to confirm the proper dose, and 2-person checking of medication infusions for accuracy.
Saleem, Ahsan; Masood, Imran
2016-01-01
Background Chronic kidney disease (CKD) alters the pharmacokinetic and pharmacodynamic response of various drugs and increases the risk of toxicity. The data regarding the pattern and predictors of medication dosing errors is scare from the developing countries. Therefore, the present study was conducted to assess the pattern and predictors of medication dosing errors in CKD patients in a tertiary care setting in Pakistan. Methods A retrospective study design was employed and medical charts of all those CKD patients who had an eGFR ≤60ml/min/1.73m2, hospitalization ≥24 hours, and admitted in the nephrology unit during January 2013 to December 2014 were assessed. Descriptive statistics and the logistic regression analysis were done using IBM SPSS version 20. Results In total, 205 medical charts were assessed. The mean age of patients was 38.64 (±16.82) years. Overall, 1534 drugs were prescribed to CKD patients, of which, nearly 34.0% drugs required dose adjustment. Among those drugs, only 41.8% were properly adjusted, and the remaining 58.2% were unadjusted. The logistic regression analysis revealed that the medication dosing errors were significantly associated with the CKD stages, i.e. stage 4 (OR 0.054; 95% CI [0.017–0.177]; p <0.001) and stage 5 (OR 0.098; 95% CI [0.040–0.241]; p <0.001), the number of prescribed medicines ≥ 5 (OR 0.306; 95% CI [0.133–0.704]; p 0.005), and the presence of a comorbidity (OR 0.455; 95% CI [0.226–0.916]; p 0.027) such as the hypertension (OR 0.453; 95% CI [0.231–0.887]; p 0.021). Conclusions It is concluded that more than half drugs prescribed to CKD patients requiring dose adjustment were unadjusted. The predictors of medication dosing errors were the severe-to-end stages of chronic kidney disease, the presence of a comorbidity such as hypertension, and a higher number of prescribed medicines. Therefore, attention should be paid to these risk factors. PMID:27367594
Poisoning Safety Fact Sheet (2015)
... in emergency departments after getting into a medication, accounting for 68% of medication-related visits for young ... and under (31% of dosing errors), followed by measurement errors (30%). 2 • For every 10 poison exposures ...
Impact of an antiretroviral stewardship strategy on medication error rates.
Shea, Katherine M; Hobbs, Athena Lv; Shumake, Jason D; Templet, Derek J; Padilla-Tolentino, Eimeira; Mondy, Kristin E
2018-05-02
The impact of an antiretroviral stewardship strategy on medication error rates was evaluated. This single-center, retrospective, comparative cohort study included patients at least 18 years of age infected with human immunodeficiency virus (HIV) who were receiving antiretrovirals and admitted to the hospital. A multicomponent approach was developed and implemented and included modifications to the order-entry and verification system, pharmacist education, and a pharmacist-led antiretroviral therapy checklist. Pharmacists performed prospective audits using the checklist at the time of order verification. To assess the impact of the intervention, a retrospective review was performed before and after implementation to assess antiretroviral errors. Totals of 208 and 24 errors were identified before and after the intervention, respectively, resulting in a significant reduction in the overall error rate ( p < 0.001). In the postintervention group, significantly lower medication error rates were found in both patient admissions containing at least 1 medication error ( p < 0.001) and those with 2 or more errors ( p < 0.001). Significant reductions were also identified in each error type, including incorrect/incomplete medication regimen, incorrect dosing regimen, incorrect renal dose adjustment, incorrect administration, and the presence of a major drug-drug interaction. A regression tree selected ritonavir as the only specific medication that best predicted more errors preintervention ( p < 0.001); however, no antiretrovirals reliably predicted errors postintervention. An antiretroviral stewardship strategy for hospitalized HIV patients including prospective audit by staff pharmacists through use of an antiretroviral medication therapy checklist at the time of order verification decreased error rates. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Sensitivity and specificity of dosing alerts for dosing errors among hospitalized pediatric patients
Stultz, Jeremy S; Porter, Kyle; Nahata, Milap C
2014-01-01
Objectives To determine the sensitivity and specificity of a dosing alert system for dosing errors and to compare the sensitivity of a proprietary system with and without institutional customization at a pediatric hospital. Methods A retrospective analysis of medication orders, orders causing dosing alerts, reported adverse drug events, and dosing errors during July, 2011 was conducted. Dosing errors with and without alerts were identified and the sensitivity of the system with and without customization was compared. Results There were 47 181 inpatient pediatric orders during the studied period; 257 dosing errors were identified (0.54%). The sensitivity of the system for identifying dosing errors was 54.1% (95% CI 47.8% to 60.3%) if customization had not occurred and increased to 60.3% (CI 54.0% to 66.3%) with customization (p=0.02). The sensitivity of the system for underdoses was 49.6% without customization and 60.3% with customization (p=0.01). Specificity of the customized system for dosing errors was 96.2% (CI 96.0% to 96.3%) with a positive predictive value of 8.0% (CI 6.8% to 9.3). All dosing errors had an alert over-ridden by the prescriber and 40.6% of dosing errors with alerts were administered to the patient. The lack of indication-specific dose ranges was the most common reason why an alert did not occur for a dosing error. Discussion Advances in dosing alert systems should aim to improve the sensitivity and positive predictive value of the system for dosing errors. Conclusions The dosing alert system had a low sensitivity and positive predictive value for dosing errors, but might have prevented dosing errors from reaching patients. Customization increased the sensitivity of the system for dosing errors. PMID:24496386
Identifying medication error chains from critical incident reports: a new analytic approach.
Huckels-Baumgart, Saskia; Manser, Tanja
2014-10-01
Research into the distribution of medication errors usually focuses on isolated stages within the medication use process. Our study aimed to provide a novel process-oriented approach to medication incident analysis focusing on medication error chains. Our study was conducted across a 900-bed teaching hospital in Switzerland. All reported 1,591 medication errors 2009-2012 were categorized using the Medication Error Index NCC MERP and the WHO Classification for Patient Safety Methodology. In order to identify medication error chains, each reported medication incident was allocated to the relevant stage of the hospital medication use process. Only 25.8% of the reported medication errors were detected before they propagated through the medication use process. The majority of medication errors (74.2%) formed an error chain encompassing two or more stages. The most frequent error chain comprised preparation up to and including medication administration (45.2%). "Non-consideration of documentation/prescribing" during the drug preparation was the most frequent contributor for "wrong dose" during the administration of medication. Medication error chains provide important insights for detecting and stopping medication errors before they reach the patient. Existing and new safety barriers need to be extended to interrupt error chains and to improve patient safety. © 2014, The American College of Clinical Pharmacology.
Implementing smart infusion pumps with dose-error reduction software: real-world experiences.
Heron, Claire
2017-04-27
Intravenous (IV) drug administration, especially with 'smart pumps', is complex and susceptible to errors. Although errors can occur at any stage of the IV medication process, most errors occur during reconstitution and administration. Dose-error reduction software (DERS) loaded on to infusion pumps incorporates a drug library with predefined upper and lower drug dose limits and infusion rates, which can reduce IV infusion errors. Although this is an important advance for patient safety at the point of care, uptake is still relatively low. This article discuses the challenges and benefits of implementing DERS in clinical practice as experienced by three UK trusts.
Sada, Oumer; Melkie, Addisu; Shibeshi, Workineh
2015-09-16
Medication errors (MEs) are important problems in all hospitalized populations, especially in intensive care unit (ICU). Little is known about the prevalence of medication prescribing errors in the ICU of hospitals in Ethiopia. The aim of this study was to assess medication prescribing errors in the ICU of Tikur Anbessa Specialized Hospital using retrospective cross-sectional analysis of patient cards and medication charts. About 220 patient charts were reviewed with a total of 1311 patient-days, and 882 prescription episodes. 359 MEs were detected; with prevalence of 40 per 100 orders. Common prescribing errors were omission errors 154 (42.89%), 101 (28.13%) wrong combination, 48 (13.37%) wrong abbreviation, 30 (8.36%) wrong dose, wrong frequency 18 (5.01%) and wrong indications 8 (2.23%). The present study shows that medication errors are common in medical ICU of Tikur Anbessa Specialized Hospital. These results suggest future targets of prevention strategies to reduce the rate of medication error.
Frequency of pediatric medication administration errors and contributing factors.
Ozkan, Suzan; Kocaman, Gulseren; Ozturk, Candan; Seren, Seyda
2011-01-01
This study examined the frequency of pediatric medication administration errors and contributing factors. This research used the undisguised observation method and Critical Incident Technique. Errors and contributing factors were classified through the Organizational Accident Model. Errors were made in 36.5% of the 2344 doses that were observed. The most frequent errors were those associated with administration at the wrong time. According to the results of this study, errors arise from problems within the system.
Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick
2007-08-01
To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (p<0.001; chi(2) test). MAEs occurred in 7.0% of 1473 non-intravenous doses pre-intervention and 4.3% of 1139 afterwards (p = 0.005; chi(2) test). Patient identity was not checked for 82.6% of 1344 doses pre-intervention and 18.9% of 1291 afterwards (p<0.001; chi(2) test). Medical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; chi(2) test). A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.
Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko
2013-03-01
To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.
Hwang, Yeonsoo; Yoon, Dukyong; Ahn, Eun Kyoung; Hwang, Hee; Park, Rae Woong
2016-12-01
To determine the risk factors and rate of medication administration error (MAE) alerts by analyzing large-scale medication administration data and related error logs automatically recorded in a closed-loop medication administration system using radio-frequency identification and barcodes. The subject hospital adopted a closed-loop medication administration system. All medication administrations in the general wards were automatically recorded in real-time using radio-frequency identification, barcodes, and hand-held point-of-care devices. MAE alert logs recorded during a full 1 year of 2012. We evaluated risk factors for MAE alerts including administration time, order type, medication route, the number of medication doses administered, and factors associated with nurse practices by logistic regression analysis. A total of 2 874 539 medication dose records from 30 232 patients (882.6 patient-years) were included in 2012. We identified 35 082 MAE alerts (1.22% of total medication doses). The MAE alerts were significantly related to administration at non-standard time [odds ratio (OR) 1.559, 95% confidence interval (CI) 1.515-1.604], emergency order (OR 1.527, 95%CI 1.464-1.594), and the number of medication doses administered (OR 0.993, 95%CI 0.992-0.993). Medication route, nurse's employment duration, and working schedule were also significantly related. The MAE alert rate was 1.22% over the 1-year observation period in the hospital examined in this study. The MAE alerts were significantly related to administration time, order type, medication route, the number of medication doses administered, nurse's employment duration, and working schedule. The real-time closed-loop medication administration system contributed to improving patient safety by preventing potential MAEs. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Venkataraman, Aishwarya; Siu, Emily; Sadasivam, Kalaimaran
2016-11-01
Medication errors, including infusion prescription errors are a major public health concern, especially in paediatric patients. There is some evidence that electronic or web-based calculators could minimise these errors. To evaluate the impact of an electronic infusion calculator on the frequency of infusion errors in the Paediatric Critical Care Unit of The Royal London Hospital, London, United Kingdom. We devised an electronic infusion calculator that calculates the appropriate concentration, rate and dose for the selected medication based on the recorded weight and age of the child and then prints into a valid prescription chart. Electronic infusion calculator was implemented from April 2015 in Paediatric Critical Care Unit. A prospective study, five months before and five months after implementation of electronic infusion calculator, was conducted. Data on the following variables were collected onto a proforma: medication dose, infusion rate, volume, concentration, diluent, legibility, and missing or incorrect patient details. A total of 132 handwritten prescriptions were reviewed prior to electronic infusion calculator implementation and 119 electronic infusion calculator prescriptions were reviewed after electronic infusion calculator implementation. Handwritten prescriptions had higher error rate (32.6%) as compared to electronic infusion calculator prescriptions (<1%) with a p < 0.001. Electronic infusion calculator prescriptions had no errors on dose, volume and rate calculation as compared to handwritten prescriptions, hence warranting very few pharmacy interventions. Use of electronic infusion calculator for infusion prescription significantly reduced the total number of infusion prescribing errors in Paediatric Critical Care Unit and has enabled more efficient use of medical and pharmacy time resources.
Comparing errors in ED computer-assisted vs conventional pediatric drug dosing and administration.
Yamamoto, Loren; Kanemori, Joan
2010-06-01
Compared to fixed-dose single-vial drug administration in adults, pediatric drug dosing and administration requires a series of calculations, all of which are potentially error prone. The purpose of this study is to compare error rates and task completion times for common pediatric medication scenarios using computer program assistance vs conventional methods. Two versions of a 4-part paper-based test were developed. Each part consisted of a set of medication administration and/or dosing tasks. Emergency department and pediatric intensive care unit nurse volunteers completed these tasks using both methods (sequence assigned to start with a conventional or a computer-assisted approach). Completion times, errors, and the reason for the error were recorded. Thirty-eight nurses completed the study. Summing the completion of all 4 parts, the mean conventional total time was 1243 seconds vs the mean computer program total time of 879 seconds (P < .001). The conventional manual method had a mean of 1.8 errors vs the computer program with a mean of 0.7 errors (P < .001). Of the 97 total errors, 36 were due to misreading the drug concentration on the label, 34 were due to calculation errors, and 8 were due to misplaced decimals. Of the 36 label interpretation errors, 18 (50%) occurred with digoxin or insulin. Computerized assistance reduced errors and the time required for drug administration calculations. A pattern of errors emerged, noting that reading/interpreting certain drug labels were more error prone. Optimizing the layout of drug labels could reduce the error rate for error-prone labels. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Outpatient Prescribing Errors and the Impact of Computerized Prescribing
Gandhi, Tejal K; Weingart, Saul N; Seger, Andrew C; Borus, Joshua; Burdick, Elisabeth; Poon, Eric G; Leape, Lucian L; Bates, David W
2005-01-01
Background Medication errors are common among inpatients and many are preventable with computerized prescribing. Relatively little is known about outpatient prescribing errors or the impact of computerized prescribing in this setting. Objective To assess the rates, types, and severity of outpatient prescribing errors and understand the potential impact of computerized prescribing. Design Prospective cohort study in 4 adult primary care practices in Boston using prescription review, patient survey, and chart review to identify medication errors, potential adverse drug events (ADEs) and preventable ADEs. Participants Outpatients over age 18 who received a prescription from 24 participating physicians. Results We screened 1879 prescriptions from 1202 patients, and completed 661 surveys (response rate 55%). Of the prescriptions, 143 (7.6%; 95% confidence interval (CI) 6.4% to 8.8%) contained a prescribing error. Three errors led to preventable ADEs and 62 (43%; 3% of all prescriptions) had potential for patient injury (potential ADEs); 1 was potentially life-threatening (2%) and 15 were serious (24%). Errors in frequency (n=77, 54%) and dose (n=26, 18%) were common. The rates of medication errors and potential ADEs were not significantly different at basic computerized prescribing sites (4.3% vs 11.0%, P=.31; 2.6% vs 4.0%, P=.16) compared to handwritten sites. Advanced checks (including dose and frequency checking) could have prevented 95% of potential ADEs. Conclusions Prescribing errors occurred in 7.6% of outpatient prescriptions and many could have harmed patients. Basic computerized prescribing systems may not be adequate to reduce errors. More advanced systems with dose and frequency checking are likely needed to prevent potentially harmful errors. PMID:16117752
Package Design Affects Accuracy Recognition for Medications.
Endestad, Tor; Wortinger, Laura A; Madsen, Steinar; Hortemo, Sigurd
2016-12-01
Our aim was to test if highlighting and placement of substance name on medication package have the potential to reduce patient errors. An unintentional overdose of medication is a large health issue that might be linked to medication package design. In two experiments, placement, background color, and the active ingredient of generic medication packages were manipulated according to best human factors guidelines to reduce causes of labeling-related patient errors. In two experiments, we compared the original packaging with packages where we varied placement of the name, dose, and background of the active ingredient. Age-relevant differences and the effect of color on medication recognition error were tested. In Experiment 1, 59 volunteers (30 elderly and 29 young students), participated. In Experiment 2, 25 volunteers participated. The most common error was the inability to identify that two different packages contained the same active ingredient (young, 41%, and elderly, 68%). This kind of error decreased with the redesigned packages (young, 8%, and elderly, 16%). Confusion errors related to color design were reduced by two thirds in the redesigned packages compared with original generic medications. Prominent placement of substance name and dose with a band of high-contrast color support recognition of the active substance in medications. A simple modification including highlighting and placing the name of the active ingredient in the upper right-hand corner of the package helps users realize that two different packages can contain the same active substance, thus reducing the risk of inadvertent medication overdose. © 2016, Human Factors and Ergonomics Society.
Package Design Affects Accuracy Recognition for Medications
Endestad, Tor; Wortinger, Laura A.; Madsen, Steinar; Hortemo, Sigurd
2016-01-01
Objective: Our aim was to test if highlighting and placement of substance name on medication package have the potential to reduce patient errors. Background: An unintentional overdose of medication is a large health issue that might be linked to medication package design. In two experiments, placement, background color, and the active ingredient of generic medication packages were manipulated according to best human factors guidelines to reduce causes of labeling-related patient errors. Method: In two experiments, we compared the original packaging with packages where we varied placement of the name, dose, and background of the active ingredient. Age-relevant differences and the effect of color on medication recognition error were tested. In Experiment 1, 59 volunteers (30 elderly and 29 young students), participated. In Experiment 2, 25 volunteers participated. Results: The most common error was the inability to identify that two different packages contained the same active ingredient (young, 41%, and elderly, 68%). This kind of error decreased with the redesigned packages (young, 8%, and elderly, 16%). Confusion errors related to color design were reduced by two thirds in the redesigned packages compared with original generic medications. Conclusion: Prominent placement of substance name and dose with a band of high-contrast color support recognition of the active substance in medications. Application: A simple modification including highlighting and placing the name of the active ingredient in the upper right-hand corner of the package helps users realize that two different packages can contain the same active substance, thus reducing the risk of inadvertent medication overdose. PMID:27591209
Nurses' role in medication safety.
Choo, Janet; Hutchinson, Alison; Bucknall, Tracey
2010-10-01
To explore the nurse's role in the process of medication management and identify the challenges associated with safe medication management in contemporary clinical practice. Medication errors have been a long-standing factor affecting consumer safety. The nursing profession has been identified as essential to the promotion of patient safety. A review of literature on medication errors and the use of electronic prescribing in medication errors. Medication management requires a multidisciplinary approach and interdisciplinary communication is essential to reduce medication errors. Information technologies can help to reduce some medication errors through eradication of transcription and dosing errors. Nurses must play a major role in the design of computerized medication systems to ensure a smooth transition to such as system. The nurses' roles in medication management cannot be over-emphasized. This is particularly true when designing a computerized medication system. The adoption of safety measures during decision making that parallel those of the aviation industry safety procedures can provide some strategies to prevent medication error. Innovations in information technology offer potential mechanisms to avert adverse events in medication management for nurses. © 2010 The Authors. Journal compilation © 2010 Blackwell Publishing Ltd.
From Here to There: Lessons from an Integrative Patient Safety Project in Rural Health Care Settings
2005-05-01
errors and patient falls. The medication errors generally involved one of three issues: incorrect dose, time, or port. Although most of the health...statistics about trends; and the summary of events related to patient safety and medical errors.12 The interplay among factors These three domains...the medical staff. We explored these issues further when administering a staff-wide Patient Safety Survey. Responses mirrored the findings that
Preventing medication errors in cancer chemotherapy.
Cohen, M R; Anderson, R W; Attilio, R M; Green, L; Muller, R J; Pruemer, J M
1996-04-01
Recommendations for preventing medication errors in cancer chemotherapy are made. Before a health care provider is granted privileges to prescribe, dispense, or administer antineoplastic agents, he or she should undergo a tailored educational program and possibly testing or certification. Appropriate reference materials should be developed. Each institution should develop a dose-verification process with as many independent checks as possible. A detailed checklist covering prescribing, transcribing, dispensing, and administration should be used. Oral orders are not acceptable. All doses should be calculated independently by the physician, the pharmacist, and the nurse. Dosage limits should be established and a review process set up for doses that exceed the limits. These limits should be entered into pharmacy computer systems, listed on preprinted order forms, stated on the product packaging, placed in strategic locations in the institution, and communicated to employees. The prescribing vocabulary must be standardized. Acronyms, abbreviations, and brand names must be avoided and steps taken to avoid other sources of confusion in the written orders, such as trailing zeros. Preprinted antineoplastic drug order forms containing checklists can help avoid errors. Manufacturers should be encouraged to avoid or eliminate ambiguities in drug names and dosing information. Patients must be educated about all aspects of their cancer chemotherapy, as patients represent a last line of defense against errors. An interdisciplinary team at each practice site should review every medication error reported. Pharmacists should be involved at all sites where antineoplastic agents are dispensed. Although it may not be possible to eliminate all medication errors in cancer chemotherapy, the risk can be minimized through specific steps. Because of their training and experience, pharmacists should take the lead in this effort.
Using mobile devices to improve the safety of medication administration processes.
Navas, H; Graffi Moltrasio, L; Ares, F; Strumia, G; Dourado, E; Alvarez, M
2015-01-01
Within preventable medical errors, those related to medications are frequent in every stage of the prescribing cycle. Nursing is responsible for maintaining each patients safety and care quality. Moreover, nurses are the last people who can detect an error in medication before its administration. Medication administration is one of the riskiest tasks in nursing. The use of information and communication technologies is related to a decrease in these errors. Including mobile devices related to 2D code reading of patients and medication will decrease the possibility of error when preparing and administering medication by nurses. A cross-platform software (iOS and Android) was developed to ensure the five Rights of the medication administration process (patient, medication, dose, route and schedule). Deployment in November showed 39% use.
Medication knowledge, certainty, and risk of errors in health care: a cross-sectional study
2011-01-01
Background Medication errors are often involved in reported adverse events. Drug therapy, prescribed by physicians, is mostly carried out by nurses, who are expected to master all aspects of medication. Research has revealed the need for improved knowledge in drug dose calculation, and medication knowledge as a whole is poorly investigated. The purpose of this survey was to study registered nurses' medication knowledge, certainty and estimated risk of errors, and to explore factors associated with good results. Methods Nurses from hospitals and primary health care establishments were invited to carry out a multiple-choice test in pharmacology, drug management and drug dose calculations (score range 0-14). Self-estimated certainty in each answer was recorded, graded from 0 = very uncertain to 3 = very certain. Background characteristics and sense of coping were recorded. Risk of error was estimated by combining knowledge and certainty scores. The results are presented as mean (±SD). Results Two-hundred and three registered nurses participated (including 16 males), aged 42.0 (9.3) years with a working experience of 12.4 (9.2) years. Knowledge scores in pharmacology, drug management and drug dose calculations were 10.3 (1.6), 7.5 (1.6), and 11.2 (2.0), respectively, and certainty scores were 1.8 (0.4), 1.9 (0.5), and 2.0 (0.6), respectively. Fifteen percent of the total answers showed a high risk of error, with 25% in drug management. Independent factors associated with high medication knowledge were working in hospitals (p < 0.001), postgraduate specialization (p = 0.01) and completion of courses in drug management (p < 0.01). Conclusions Medication knowledge was found to be unsatisfactory among practicing nurses, with a significant risk for medication errors. The study revealed a need to improve the nurses' basic knowledge, especially when referring to drug management. PMID:21791106
Adverse Drug Events caused by Serious Medication Administration Errors
Sawarkar, Abhivyakti; Keohane, Carol A.; Maviglia, Saverio; Gandhi, Tejal K; Poon, Eric G
2013-01-01
OBJECTIVE To determine how often serious or life-threatening medication administration errors with the potential to cause patient harm (or potential adverse drug events) result in actual patient harm (or adverse drug events (ADEs)) in the hospital setting. DESIGN Retrospective chart review of clinical events that transpired following observed medication administration errors. BACKGROUND Medication errors are common at the medication administration stage for hospitalized patients. While many of these errors are considered capable of causing patient harm, it is not clear how often patients are actually harmed by these errors. METHODS In a previous study where 14,041 medication administrations in an acute-care hospital were directly observed, investigators discovered 1271 medication administration errors, of which 133 had the potential to cause serious or life-threatening harm to patients and were considered serious or life-threatening potential ADEs. In the current study, clinical reviewers conducted detailed chart reviews of cases where a serious or life-threatening potential ADE occurred to determine if an actual ADE developed following the potential ADE. Reviewers further assessed the severity of the ADE and attribution to the administration error. RESULTS Ten (7.5% [95% C.I. 6.98, 8.01]) actual adverse drug events or ADEs resulted from the 133 serious and life-threatening potential ADEs, of which 6 resulted in significant, three in serious, and one life threatening injury. Therefore 4 (3% [95% C.I. 2.12, 3.6]) serious and life threatening potential ADEs led to serious or life threatening ADEs. Half of the ten actual ADEs were caused by dosage or monitoring errors for anti-hypertensives. The life threatening ADE was caused by an error that was both a transcription and a timing error. CONCLUSION Potential ADEs at the medication administration stage can cause serious patient harm. Given previous estimates of serious or life-threatening potential ADE of 1.33 per 100 medication doses administered, in a hospital where 6 million doses are administered per year, about 4000 preventable ADEs would be attributable to medication administration errors annually. PMID:22791691
Medical Errors: Tips to Help Prevent Them
... consider A study by the Massachusetts College of Pharmacy and Allied Health Sciences found that 88% of medical errors involve the wrong drug or the wrong dose. This is one more reason why you should be a ... up refills at the pharmacy. In the hospital, have in writing the medicine ...
van der Veen, Willem; van den Bemt, Patricia M L A; Wouters, Hans; Bates, David W; Twisk, Jos W R; de Gier, Johan J; Taxis, Katja; Duyvendak, Michiel; Luttikhuis, Karen Oude; Ros, Johannes J W; Vasbinder, Erwin C; Atrafi, Maryam; Brasse, Bjorn; Mangelaars, Iris
2018-04-01
To study the association of workarounds with medication administration errors using barcode-assisted medication administration (BCMA), and to determine the frequency and types of workarounds and medication administration errors. A prospective observational study in Dutch hospitals using BCMA to administer medication. Direct observation was used to collect data. Primary outcome measure was the proportion of medication administrations with one or more medication administration errors. Secondary outcome was the frequency and types of workarounds and medication administration errors. Univariate and multivariate multilevel logistic regression analysis were used to assess the association between workarounds and medication administration errors. Descriptive statistics were used for the secondary outcomes. We included 5793 medication administrations for 1230 inpatients. Workarounds were associated with medication administration errors (adjusted odds ratio 3.06 [95% CI: 2.49-3.78]). Most commonly, procedural workarounds were observed, such as not scanning at all (36%), not scanning patients because they did not wear a wristband (28%), incorrect medication scanning, multiple medication scanning, and ignoring alert signals (11%). Common types of medication administration errors were omissions (78%), administration of non-ordered drugs (8.0%), and wrong doses given (6.0%). Workarounds are associated with medication administration errors in hospitals using BCMA. These data suggest that BCMA needs more post-implementation evaluation if it is to achieve the intended benefits for medication safety. In hospitals using barcode-assisted medication administration, workarounds occurred in 66% of medication administrations and were associated with large numbers of medication administration errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. Themore » dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less
Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif
2017-01-01
Introduction Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%–38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. Methods We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Results Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p <0.0001), missing frequency (3.5% to 2.2%, p=0.04), missing strength errors (32.4% to 10.2%, p <0.0001) and legibility (0.7% to 0.2%, p=0.005). E-prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). Conclusion A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive. PMID:28874948
Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif
2017-08-01
Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%-38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p <0.0001), missing frequency (3.5% to 2.2%, p=0.04), missing strength errors (32.4% to 10.2%, p <0.0001) and legibility (0.7% to 0.2%, p=0.005). E-prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive.
Systematic literature review of hospital medication administration errors in children
Ameer, Ahmed; Dhillon, Soraya; Peters, Mark J; Ghaleb, Maisoon
2015-01-01
Objective Medication administration is the last step in the medication process. It can act as a safety net to prevent unintended harm to patients if detected. However, medication administration errors (MAEs) during this process have been documented and thought to be preventable. In pediatric medicine, doses are usually administered based on the child’s weight or body surface area. This in turn increases the risk of drug miscalculations and therefore MAEs. The aim of this review is to report MAEs occurring in pediatric inpatients. Methods Twelve bibliographic databases were searched for studies published between January 2000 and February 2015 using “medication administration errors”, “hospital”, and “children” related terminologies. Handsearching of relevant publications was also carried out. A second reviewer screened articles for eligibility and quality in accordance with the inclusion/exclusion criteria. Key findings A total of 44 studies were systematically reviewed. MAEs were generally defined as a deviation of dose given from that prescribed; this included omitted doses and administration at the wrong time. Hospital MAEs in children accounted for a mean of 50% of all reported medication error reports (n=12,588). It was also identified in a mean of 29% of doses observed (n=8,894). The most prevalent type of MAEs related to preparation, infusion rate, dose, and time. This review has identified five types of interventions to reduce hospital MAEs in children: barcode medicine administration, electronic prescribing, education, use of smart pumps, and standard concentration. Conclusion This review has identified a wide variation in the prevalence of hospital MAEs in children. This is attributed to the definition and method used to investigate MAEs. The review also illustrated the complexity and multifaceted nature of MAEs. Therefore, there is a need to develop a set of safety measures to tackle these errors in pediatric practice. PMID:29354530
Kiymaz, Dilek; Koç, Zeliha
2018-03-01
To determine individual and professional factors affecting the tendency of emergency unit nurses to make medical errors and their attitudes towards these errors in Turkey. Compared with other units, the emergency unit is an environment where there is an increased tendency for making medical errors due to its intensive and rapid pace, noise and complex and dynamic structure. A descriptive cross-sectional study. The study was carried out from 25 July 2014-16 September 2015 with the participation of 284 nurses who volunteered to take part in the study. Data were gathered using the data collection survey for nurses, the Medical Error Tendency Scale and the Medical Error Attitude Scale. It was determined that 40.1% of the nurses previously witnessed medical errors, 19.4% made a medical error in the last year, 17.6% of medical errors were caused by medication errors where the wrong medication was administered in the wrong dose, and none of the nurses filled out a case report form about the medical errors they made. Regarding the factors that caused medical errors in the emergency unit, 91.2% of the nurses stated excessive workload as a cause; 85.1% stated an insufficient number of nurses; and 75.4% stated fatigue, exhaustion and burnout. The study showed that nurses who loved their job were satisfied with their unit and who always worked during day shifts had a lower medical error tendency. It is suggested to consider the following actions: increase awareness about medical errors, organise training to reduce errors in medication administration, develop procedures and protocols specific to the emergency unit health care and create an environment which is not punitive wherein nurses can safely report medical errors. © 2017 John Wiley & Sons Ltd.
Vélez-Díaz-Pallarés, Manuel; Delgado-Silveira, Eva; Carretero-Accame, María Emilia; Bermejo-Vicedo, Teresa
2013-01-01
To identify actions to reduce medication errors in the process of drug prescription, validation and dispensing, and to evaluate the impact of their implementation. A Health Care Failure Mode and Effect Analysis (HFMEA) was supported by a before-and-after medication error study to measure the actual impact on error rate after the implementation of corrective actions in the process of drug prescription, validation and dispensing in wards equipped with computerised physician order entry (CPOE) and unit-dose distribution system (788 beds out of 1080) in a Spanish university hospital. The error study was carried out by two observers who reviewed medication orders on a daily basis to register prescription errors by physicians and validation errors by pharmacists. Drugs dispensed in the unit-dose trolleys were reviewed for dispensing errors. Error rates were expressed as the number of errors for each process divided by the total opportunities for error in that process times 100. A reduction in prescription errors was achieved by providing training for prescribers on CPOE, updating prescription procedures, improving clinical decision support and automating the software connection to the hospital census (relative risk reduction (RRR), 22.0%; 95% CI 12.1% to 31.8%). Validation errors were reduced after optimising time spent in educating pharmacy residents on patient safety, developing standardised validation procedures and improving aspects of the software's database (RRR, 19.4%; 95% CI 2.3% to 36.5%). Two actions reduced dispensing errors: reorganising the process of filling trolleys and drawing up a protocol for drug pharmacy checking before delivery (RRR, 38.5%; 95% CI 14.1% to 62.9%). HFMEA facilitated the identification of actions aimed at reducing medication errors in a healthcare setting, as the implementation of several of these led to a reduction in errors in the process of drug prescription, validation and dispensing.
Approach to the Pediatric Prescription in a Community Pharmacy
Benavides, Sandra; Huynh, Donna; Morgan, Jill; Briars, Leslie
2011-01-01
Pediatric patients are more susceptible to medication errors for a variety of reasons including physical and social differences and the necessity for patient-specific dosing. As such, community pharmacists may feel uncomfortable in verifying or dispensing a prescription for a pediatric patient. However, the use of a systematic approach to the pediatric prescription can provide confidence to pharmacists and minimize the possibility of a medication error. The objective of this article is to provide the community pharmacist with an overview of the potential areas of medication errors in a prescription for a pediatric patient. Additionally, the article guides the community pharmacist through a pediatric prescription, highlighting common areas of medication errors. PMID:22768015
Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick
2007-01-01
Objectives To assess the impact of a closed‐loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants Before‐and‐after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention Closed‐loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results Prescribing errors were identified in 3.8% of 2450 medication orders pre‐intervention and 2.0% of 2353 orders afterwards (p<0.001; χ2 test). MAEs occurred in 7.0% of 1473 non‐intravenous doses pre‐intervention and 4.3% of 1139 afterwards (p = 0.005; χ2 test). Patient identity was not checked for 82.6% of 1344 doses pre‐intervention and 18.9% of 1291 afterwards (p<0.001; χ2 test). Medical staff required 15 s to prescribe a regular inpatient drug pre‐intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre‐intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions A closed‐loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication‐related tasks increased. PMID:17693676
A systematic review of clinical pharmacist interventions in paediatric hospital patients.
Drovandi, Aaron; Robertson, Kelvin; Tucker, Matthew; Robinson, Niechole; Perks, Stephen; Kairuz, Therése
2018-06-19
Clinical pharmacists provide beneficial services to adult patients, though their benefits for paediatric hospital patients are less defined. Five databases were searched using the MeSH terms 'clinical pharmacist', 'paediatric/paediatric', 'hospital', and 'intervention' for studies with paediatric patients conducted in hospital settings, and described pharmacist-initiated interventions, published between January 2000 and October 2017. The search strategy after full-text review identified 12 articles matching the eligibility criteria. Quality appraisal checklists from the Joanna Briggs Institute were used to appraise the eligible articles. Clinical pharmacist services had a positive impact on paediatric patient care. Medication errors intercepted by pharmacists included over- and under-dosing, missed doses, medication history gaps, allergies, and near-misses. Interventions to address these errors were positively received, and implemented by physicians, with an average acceptance rate of over 95%. Clinical pharmacist-initiated education resulted in improved medication understanding and adherence, improved patient satisfaction, and control of chronic medical conditions. This review found that clinical pharmacists in paediatric wards may reduce drug-related problems and improve patient outcomes. The benefits of pharmacist involvement appear greatest when directly involved in ward rounds, due to being able to more rapidly identify medication errors during the prescribing phase, and provide real-time advice and recommendations to prescribers. What is Known: • Complex paediatric conditions can require multiple pharmaceutical treatments, utilised in a safe manner to ensure good patient outcomes • The benefits of pharmacist interventions when using these treatments are well-documented in adult patients, though less so in paediatric patients What is New: • Pharmacists are adept at identifying and managing medication errors for paediatric patients, including incorrect doses, missed doses, and gaps in medication history • Interventions recommended by pharmacists are generally well-accepted by prescribing physicians, especially when recommendations can be made during the prescribing phase of treatment.
Risør, Bettina Wulff; Lisby, Marianne; Sørensen, Jan
2018-02-01
Automated medication systems have been found to reduce errors in the medication process, but little is known about the cost-effectiveness of such systems. The objective of this study was to perform a model-based indirect cost-effectiveness comparison of three different, real-world automated medication systems compared with current standard practice. The considered automated medication systems were a patient-specific automated medication system (psAMS), a non-patient-specific automated medication system (npsAMS), and a complex automated medication system (cAMS). The economic evaluation used original effect and cost data from prospective, controlled, before-and-after studies of medication systems implemented at a Danish hematological ward and an acute medical unit. Effectiveness was described as the proportion of clinical and procedural error opportunities that were associated with one or more errors. An error was defined as a deviation from the electronic prescription, from standard hospital policy, or from written procedures. The cost assessment was based on 6-month standardization of observed cost data. The model-based comparative cost-effectiveness analyses were conducted with system-specific assumptions of the effect size and costs in scenarios with consumptions of 15,000, 30,000, and 45,000 doses per 6-month period. With 30,000 doses the cost-effectiveness model showed that the cost-effectiveness ratio expressed as the cost per avoided clinical error was €24 for the psAMS, €26 for the npsAMS, and €386 for the cAMS. Comparison of the cost-effectiveness of the three systems in relation to different valuations of an avoided error showed that the psAMS was the most cost-effective system regardless of error type or valuation. The model-based indirect comparison against the conventional practice showed that psAMS and npsAMS were more cost-effective than the cAMS alternative, and that psAMS was more cost-effective than npsAMS.
A decade of Australian methotrexate dosing errors.
Cairns, Rose; Brown, Jared A; Lynch, Ann-Maree; Robinson, Jeff; Wylie, Carol; Buckley, Nicholas A
2016-06-06
Accidental daily dosing of methotrexate can result in life-threatening toxicity. We investigated methotrexate dosing errors reported to the National Coronial Information System (NCIS), the Therapeutic Goods Administration Database of Adverse Event Notifications (TGA DAEN) and Australian Poisons Information Centres (PICs). A retrospective review of coronial cases in the NCIS (2000-2014), and of reports to the TGA DAEN (2004-2014) and Australian PICs (2004-2015). Cases were included if dosing errors were accidental, with evidence of daily dosing on at least 3 consecutive days. Events per year, dose, consecutive days of methotrexate administration, reasons for the error, clinical features. Twenty-two deaths linked with methotrexate were identified in the NCIS, including seven cases in which erroneous daily dosing was documented. Methotrexate medication error was listed in ten cases in the DAEN, including two deaths. Australian PIC databases contained 92 cases, with a worrying increase seen during 2014-2015. Reasons for the errors included patient misunderstanding and incorrect packaging of dosette packs by pharmacists. The recorded clinical effects of daily dosage were consistent with those previously reported for methotrexate toxicity. Dosing errors with methotrexate can be lethal and continue to occur despite a number of safety initiatives in the past decade. Further strategies to reduce these preventable harms need to be implemented and evaluated. Recent suggestions include further changes in packet size, mandatory weekly dosing labelling on packaging, improving education, and including alerts in prescribing and dispensing software.
Poon, Eric G; Cina, Jennifer L; Churchill, William W; Mitton, Patricia; McCrea, Michelle L; Featherstone, Erica; Keohane, Carol A; Rothschild, Jeffrey M; Bates, David W; Gandhi, Tejal K
2005-01-01
We performed a direct observation pre-post study to evaluate the impact of barcode technology on medication dispensing errors and potential adverse drug events in the pharmacy of a tertiary-academic medical center. We found that barcode technology significantly reduced the rate of target dispensing errors leaving the pharmacy by 85%, from 0.37% to 0.06%. The rate of potential adverse drug events (ADEs) due to dispensing errors was also significantly reduced by 63%, from 0.19% to 0.069%. In a 735-bed hospital where 6 million doses of medications are dispensed per year, this technology is expected to prevent about 13,000 dispensing errors and 6,000 potential ADEs per year. PMID:16779372
Miller, Marlene R; Robinson, Karen A; Lubomski, Lisa H; Rinke, Michael L; Pronovost, Peter J
2007-01-01
Background Although children are at the greatest risk for medication errors, little is known about the overall epidemiology of these errors, where the gaps are in our knowledge, and to what extent national medication error reduction strategies focus on children. Objective To synthesise peer reviewed knowledge on children's medication errors and on recommendations to improve paediatric medication safety by a systematic literature review. Data sources PubMed, Embase and Cinahl from 1 January 2000 to 30 April 2005, and 11 national entities that have disseminated recommendations to improve medication safety. Study selection Inclusion criteria were peer reviewed original data in English language. Studies that did not separately report paediatric data were excluded. Data extraction Two reviewers screened articles for eligibility and for data extraction, and screened all national medication error reduction strategies for relevance to children. Data synthesis From 358 articles identified, 31 were included for data extraction. The definition of medication error was non‐uniform across the studies. Dispensing and administering errors were the most poorly and non‐uniformly evaluated. Overall, the distributional epidemiological estimates of the relative percentages of paediatric error types were: prescribing 3–37%, dispensing 5–58%, administering 72–75%, and documentation 17–21%. 26 unique recommendations for strategies to reduce medication errors were identified; none were based on paediatric evidence. Conclusions Medication errors occur across the entire spectrum of prescribing, dispensing, and administering, are common, and have a myriad of non‐evidence based potential reduction strategies. Further research in this area needs a firmer standardisation for items such as dose ranges and definitions of medication errors, broader scope beyond inpatient prescribing errors, and prioritisation of implementation of medication error reduction strategies. PMID:17403758
Characteristics of pediatric chemotherapy medication errors in a national error reporting database.
Rinke, Michael L; Shore, Andrew D; Morlock, Laura; Hicks, Rodney W; Miller, Marlene R
2007-07-01
Little is known regarding chemotherapy medication errors in pediatrics despite studies suggesting high rates of overall pediatric medication errors. In this study, the authors examined patterns in pediatric chemotherapy errors. The authors queried the United States Pharmacopeia MEDMARX database, a national, voluntary, Internet-accessible error reporting system, for all error reports from 1999 through 2004 that involved chemotherapy medications and patients aged <18 years. Of the 310 pediatric chemotherapy error reports, 85% reached the patient, and 15.6% required additional patient monitoring or therapeutic intervention. Forty-eight percent of errors originated in the administering phase of medication delivery, and 30% originated in the drug-dispensing phase. Of the 387 medications cited, 39.5% were antimetabolites, 14.0% were alkylating agents, 9.3% were anthracyclines, and 9.3% were topoisomerase inhibitors. The most commonly involved chemotherapeutic agents were methotrexate (15.3%), cytarabine (12.1%), and etoposide (8.3%). The most common error types were improper dose/quantity (22.9% of 327 cited error types), wrong time (22.6%), omission error (14.1%), and wrong administration technique/wrong route (12.2%). The most common error causes were performance deficit (41.3% of 547 cited error causes), equipment and medication delivery devices (12.4%), communication (8.8%), knowledge deficit (6.8%), and written order errors (5.5%). Four of the 5 most serious errors occurred at community hospitals. Pediatric chemotherapy errors often reached the patient, potentially were harmful, and differed in quality between outpatient and inpatient areas. This study indicated which chemotherapeutic agents most often were involved in errors and that administering errors were common. Investigation is needed regarding targeted medication administration safeguards for these high-risk medications. Copyright (c) 2007 American Cancer Society.
Surana, Sikander; Kumar, Neeru; Vasudeva, Amita; Shaikh, Gulvahid; Jhaveri, Kenar D; Shah, Hitesh; Malieckal, Deepa; Fogel, Joshua; Sidhu, Gurwinder; Rubinstein, Sofia
2017-01-17
Drug dosing errors result in adverse patient outcomes and are more common in patients with chronic kidney disease (CKD). As internists treat the majority of patients with CKD, we study if Internal Medicine house-staff have awareness and knowledge about the correct dosage of commonly used medications for those with CKD. A cross-sectional survey was performed and included 341 participants. The outcomes were the awareness of whether a medication needs dose adjustment in patients with CKD and whether there was knowledge for the level of glomerular filtration rate (GFR) a medication needs to be adjusted. The overall pattern for all post-graduate year (PGY) groups in all medication classes was a lack of awareness and knowledge. For awareness, there were statistically significant increased mean differences for PGY2 and PGY3 as compared to PGY1 for allergy, endocrine, gastrointestinal, and rheumatologic medication classes but not for analgesic, cardiovascular, and neuropsychotropic medication classes. For knowledge, there were statistically significant increased mean differences for PGY2 and PGY3 as compared to PGY1 for allergy, cardiovascular, endocrine, and gastrointestinal, medication classes but not for analgesic, neuropsychotropic, and rheumatologic medication classes. Internal Medicine house-staff across all levels of training demonstrated poor awareness and knowledge for many medication classes in CKD patients. Internal Medicine house-staff should receive more nephrology exposure and formal didactic educational training during residency to better manage complex treatment regimens and prevent medication dosing errors.
Simonsen, Bjoerg O; Daehlin, Gro K; Johansson, Inger; Farup, Per G
2014-11-21
Nurses experience insufficient medication knowledge; particularly in drug dose calculations, but also in drug management and pharmacology. The weak knowledge could be a result of deficiencies in the basic nursing education, or lack of continuing maintenance training during working years. The aim of this study was to compare the medication knowledge, certainty and risk of error between graduating bachelor students in nursing and experienced registered nurses. Bachelor students in closing term and registered nurses with at least one year job experience underwent a multiple choice test in pharmacology, drug management and drug dose calculations: 3x14 questions with 3-4 alternative answers (score 0-42). Certainty of each answer was recorded with score 0-3, 0-1 indicating need for assistance. Risk of error was scored 1-3, where 3 expressed high risk: being certain that a wrong answer was correct. The results are presented as mean and (SD). Participants were 243 graduating students (including 29 men), aged 28.2 (7.6) years, and 203 registered nurses (including 16 men), aged 42.0 (9.3) years and with a working experience of 12.4 years (9.2). The knowledge among the nurses was found to be superior to that of the students: 68.9%(8.0) and 61.5%(7.8) correct answers, respectively, (p < 0.001). The difference was largest in drug management and dose calculations. The improvement occurred during the first working year. The nurses expressed higher degree of certainty and the risk of error was lower, both overall and for each topic (p < 0.01). Low risk of error was associated with high knowledge and high sense of coping (p < 0.001). The medication knowledge among experienced nurses was superior to bachelor students in nursing, but nevertheless insufficient. As much as 25% of the answers to the drug management questions would lead to high risk of error. More emphasis should be put into the basic nursing education and in the introduction to medication procedures in clinical practice to improve the nurses' medication knowledge and reduce the risk of error.
Dispensing error rate after implementation of an automated pharmacy carousel system.
Oswald, Scott; Caldwell, Richard
2007-07-01
A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS). The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist. Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS. The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.
The cost of implementing inpatient bar code medication administration.
Sakowski, Julie Ann; Ketchel, Alan
2013-02-01
To calculate the costs associated with implementing and operating an inpatient bar-code medication administration (BCMA) system in the community hospital setting and to estimate the cost per harmful error prevented. This is a retrospective, observational study. Costs were calculated from the hospital perspective and a cost-consequence analysis was performed to estimate the cost per preventable adverse drug event averted. Costs were collected from financial records and key informant interviews at 4 not-for profit community hospitals. Costs included direct expenditures on capital, infrastructure, additional personnel, and the opportunity costs of time for existing personnel working on the project. The number of adverse drug events prevented using BCMA was estimated by multiplying the number of doses administered using BCMA by the rate of harmful errors prevented by interventions in response to system warnings. Our previous work found that BCMA identified and intercepted medication errors in 1.1% of doses administered, 9% of which potentially could have resulted in lasting harm. The cost of implementing and operating BCMA including electronic pharmacy management and drug repackaging over 5 years is $40,000 (range: $35,600 to $54,600) per BCMA-enabled bed and $2000 (range: $1800 to $2600) per harmful error prevented. BCMA can be an effective and potentially cost-saving tool for preventing the harm and costs associated with medication errors.
Elliott, Rohan A; Lee, Cik Yin; Hussainy, Safeera Y
2016-06-01
Objectives The aims of the study were to investigate discrepancies between general practitioners' paper medication orders and pharmacy-prepared electronic medication administration charts, back-up paper charts and dose-administration aids, as well as delays between prescribing, charting and administration, at a 90-bed residential aged care facility that used a hybrid paper-electronic medication management system. Methods A cross-sectional audit of medication orders, medication charts and dose-administration aids was performed to identify discrepancies. In addition, a retrospective audit was performed of delays between prescribing and availability of an updated electronic medication administration chart. Medication administration records were reviewed retrospectively to determine whether discrepancies and delays led to medication administration errors. Results Medication records for 88 residents (mean age 86 years) were audited. Residents were prescribed a median of eight regular medicines (interquartile range 5-12). One hundred and twenty-five discrepancies were identified. Forty-seven discrepancies, affecting 21 (24%) residents, led to a medication administration error. The most common discrepancies were medicine omission (44.0%) and extra medicine (19.2%). Delays from when medicines were prescribed to when they appeared on the electronic medication administration chart ranged from 18min to 98h. On nine occasions (for 10% of residents) the delay contributed to missed doses, usually antibiotics. Conclusion Medication discrepancies and delays were common. Improved systems for managing medication orders and charts are needed. What is known about the topic? Hybrid paper-electronic medication management systems, in which prescribers' orders are transcribed into an electronic system by pharmacy technicians and pharmacists to create medication administration charts, are increasingly replacing paper-based medication management systems in Australian residential aged care facilities. The accuracy and safety of these systems has not been studied. What does this paper add? The present study identified discrepancies between general practitioners' orders and pharmacy-prepared electronic medication administration charts, back-up paper medication charts and dose-administration aids, as well as delays between ordering, charting and administering medicines. Discrepancies and delays sometimes led to medication administration errors. What are the implications for practitioners? Facilities that use hybrid systems need to implement robust systems for communicating medication changes to their pharmacy and reconciling prescribers' orders against pharmacy-generated medication charts and dose-administration aids. Fully integrated, paperless medication management systems, in which prescribers' electronic medication orders directly populate an electronic medication administration chart and are automatically communicated to the facility's pharmacy, could improve patient safety.
Medication errors in the Middle East countries: a systematic review of the literature.
Alsulami, Zayed; Conroy, Sharon; Choonara, Imti
2013-04-01
Medication errors are a significant global concern and can cause serious medical consequences for patients. Little is known about medication errors in Middle Eastern countries. The objectives of this systematic review were to review studies of the incidence and types of medication errors in Middle Eastern countries and to identify the main contributory factors involved. A systematic review of the literature related to medication errors in Middle Eastern countries was conducted in October 2011 using the following databases: Embase, Medline, Pubmed, the British Nursing Index and the Cumulative Index to Nursing & Allied Health Literature. The search strategy included all ages and languages. Inclusion criteria were that the studies assessed or discussed the incidence of medication errors and contributory factors to medication errors during the medication treatment process in adults or in children. Forty-five studies from 10 of the 15 Middle Eastern countries met the inclusion criteria. Nine (20 %) studies focused on medication errors in paediatric patients. Twenty-one focused on prescribing errors, 11 measured administration errors, 12 were interventional studies and one assessed transcribing errors. Dispensing and documentation errors were inadequately evaluated. Error rates varied from 7.1 % to 90.5 % for prescribing and from 9.4 % to 80 % for administration. The most common types of prescribing errors reported were incorrect dose (with an incidence rate from 0.15 % to 34.8 % of prescriptions), wrong frequency and wrong strength. Computerised physician rder entry and clinical pharmacist input were the main interventions evaluated. Poor knowledge of medicines was identified as a contributory factor for errors by both doctors (prescribers) and nurses (when administering drugs). Most studies did not assess the clinical severity of the medication errors. Studies related to medication errors in the Middle Eastern countries were relatively few in number and of poor quality. Educational programmes on drug therapy for doctors and nurses are urgently needed.
Medication errors: problems and recommendations from a consensus meeting
Agrawal, Abha; Aronson, Jeffrey K; Britten, Nicky; Ferner, Robin E; de Smet, Peter A; Fialová, Daniela; Fitzgerald, Richard J; Likić, Robert; Maxwell, Simon R; Meyboom, Ronald H; Minuz, Pietro; Onder, Graziano; Schachter, Michael; Velo, Giampaolo
2009-01-01
Here we discuss 15 recommendations for reducing the risks of medication errors: Provision of sufficient undergraduate learning opportunities to make medical students safe prescribers. Provision of opportunities for students to practise skills that help to reduce errors. Education of students about common types of medication errors and how to avoid them. Education of prescribers in taking accurate drug histories. Assessment in medical schools of prescribing knowledge and skills and demonstration that newly qualified doctors are safe prescribers. European harmonization of prescribing and safety recommendations and regulatory measures, with regular feedback about rational drug use. Comprehensive assessment of elderly patients for declining function. Exploration of low-dose regimens for elderly patients and preparation of special formulations as required. Training for all health-care professionals in drug use, adverse effects, and medication errors in elderly people. More involvement of pharmacists in clinical practice. Introduction of integrated prescription forms and national implementation in individual countries. Development of better monitoring systems for detecting medication errors, based on classification and analysis of spontaneous reports of previous reactions, and for investigating the possible role of medication errors when patients die. Use of IT systems, when available, to provide methods of avoiding medication errors; standardization, proper evaluation, and certification of clinical information systems. Nonjudgmental communication with patients about their concerns and elicitation of symptoms that they perceive to be adverse drug reactions. Avoidance of defensive reactions if patients mention symptoms resulting from medication errors. PMID:19594525
Buetow, Stephen; Henshaw, Jenny; Bryant, Linda; O'Sullivan, Deirdre
2010-01-01
Background. Common but seldom published are Parkinson's disease (PD) medication errors involving late, extra, or missed doses. These errors can reduce medication effectiveness and the quality of life of people with PD and their caregivers. Objective. To explore lay perspectives of factors contributing to medication timing errors for PD in hospital and community settings. Design and Methods. This qualitative research purposively sampled individuals with PD, or a proxy of their choice, throughout New Zealand during 2008-2009. Data collection involved 20 semistructured, personal interviews by telephone. A general inductive analysis of the data identified core insights consistent with the study objective. Results. Five themes help to account for possible timing adherence errors by people with PD, their caregivers or professionals. The themes are the abrupt withdrawal of PD medication; wrong, vague or misread instructions; devaluation of the lay role in managing PD medications; deficits in professional knowledge and in caring behavior around PD in formal health care settings; and lay forgetfulness. Conclusions. The results add to the limited published research on medication errors in PD and help to confirm anecdotal experience internationally. They indicate opportunities for professionals and lay people to work together to reduce errors in the timing of medication for PD in hospital and community settings. PMID:20975777
Methodological variations and their effects on reported medication administration error rates.
McLeod, Monsey Chan; Barber, Nick; Franklin, Bryony Dean
2013-04-01
Medication administration errors (MAEs) are a problem, yet methodological variation between studies presents a potential barrier to understanding how best to increase safety. Using the UK as a case-study, we systematically summarised methodological variations in MAE studies, and their effects on reported MAE rates. Nine healthcare databases were searched for quantitative observational MAE studies in UK hospitals. Methodological variations were analysed and meta-analysis of MAE rates performed using studies that used the same definitions. Odds ratios (OR) were calculated to compare MAE rates between intravenous (IV) and non-IV doses, and between paediatric and adult doses. We identified 16 unique studies reporting three MAE definitions, 44 MAE subcategories and four different denominators. Overall adult MAE rates were 5.6% of a total of 21 533 non-IV opportunities for error (OE) (95% CI 4.6% to 6.7%) and 35% of a total of 154 IV OEs (95% CI 2% to 68%). MAEs were five times more likely in IV than non-IV doses (pooled OR 5.1; 95% CI 3.5 to 7.5). Including timing errors of ±30 min increased the MAE rate from 27% to 69% of 320 IV doses in one study. Five studies were unclear as to whether the denominator included dose omissions; omissions accounted for 0%-13% of IV doses and 1.8%-5.1% of non-IV doses. Wide methodological variations exist even within one country, some with significant effects on reported MAE rates. We have made recommendations for future MAE studies; these may be applied both within and outside the UK.
Comparison of Errors Using Two Length-Based Tape Systems for Prehospital Care in Children.
Rappaport, Lara D; Brou, Lina; Givens, Tim; Mandt, Maria; Balakas, Ashley; Roswell, Kelley; Kotas, Jason; Adelgais, Kathleen M
2016-01-01
The use of a length/weight-based tape (LBT) for equipment size and drug dosing for pediatric patients is recommended in a joint statement by multiple national organizations. A new system, known as Handtevy™, allows for rapid determination of critical drug doses without performing calculations. To compare two LBT systems for dosing errors and time to medication administration in simulated prehospital scenarios. This was a prospective randomized trial comparing the Broselow Pediatric Emergency Tape™ (Broselow) and Handtevy LBT™ (Handtevy). Paramedics performed 2 pediatric simulations: cardiac arrest with epinephrine administration and hypoglycemia mandating dextrose. Each scenario was repeated utilizing both systems with a 1-year-old and 5-year-old size manikin. Facilitators recorded identified errors and time points of critical actions including time to medication. We enrolled 80 paramedics, performing 320 simulations. For Dextrose, there were significantly more errors with Broselow (63.8%) compared to Handtevy (13.8%) and time to administration was longer with the Broselow system (220 seconds vs. 173 seconds). For epinephrine, the LBTs were similar in overall error rate (Broselow 21.3% vs. Handtevy 16.3%) and time to administration (89 vs. 91 seconds). Cognitive errors were more frequent when using the Broselow compared to Handtevy, particularly with dextrose administration. The frequency of procedural errors was similar between the two LBT systems. In simulated prehospital scenarios, use of the Handtevy LBT system resulted in fewer errors for dextrose administration compared to the Broselow LBT, with similar time to administration and accuracy of epinephrine administration.
Prescribing Errors Involving Medication Dosage Forms
Lesar, Timothy S
2002-01-01
CONTEXT Prescribing errors involving medication dose formulations have been reported to occur frequently in hospitals. No systematic evaluations of the characteristics of errors related to medication dosage formulation have been performed. OBJECTIVE To quantify the characteristics, frequency, and potential adverse patient effects of prescribing errors involving medication dosage forms . DESIGN Evaluation of all detected medication prescribing errors involving or related to medication dosage forms in a 631-bed tertiary care teaching hospital. MAIN OUTCOME MEASURES Type, frequency, and potential for adverse effects of prescribing errors involving or related to medication dosage forms. RESULTS A total of 1,115 clinically significant prescribing errors involving medication dosage forms were detected during the 60-month study period. The annual number of detected errors increased throughout the study period. Detailed analysis of the 402 errors detected during the last 16 months of the study demonstrated the most common errors to be: failure to specify controlled release formulation (total of 280 cases; 69.7%) both when prescribing using the brand name (148 cases; 36.8%) and when prescribing using the generic name (132 cases; 32.8%); and prescribing controlled delivery formulations to be administered per tube (48 cases; 11.9%). The potential for adverse patient outcome was rated as potentially “fatal or severe” in 3 cases (0.7%), and “serious” in 49 cases (12.2%). Errors most commonly involved cardiovascular agents (208 cases; 51.7%). CONCLUSIONS Hospitalized patients are at risk for adverse outcomes due to prescribing errors related to inappropriate use of medication dosage forms. This information should be considered in the development of strategies to prevent adverse patient outcomes resulting from such errors. PMID:12213138
[Pharmaceutical care strategies to prevent medication errors].
Ucha-Samartín, Marisol; Martínez-López de Castro, Noemí; Troncoso-Mariño, Amelia; Campelo-Sánchez, Eva; Vázquez-López, Cristina; Inaraja-Bobo, María Teresa
2009-08-01
To evaluate the impact of implementing new programs to improve the quality of the pharmaceutical care and unit-dose distribution system for in-patients. An observational and prospective study was carried out in a general hospital during two different six-monthly period. Transcription and dispensation errors were evaluated in twelve wards during the first six months. Then, two new measures were introduced: the first- reference ward-pharmacist and the second-a new protocol for checking medication on the ward. Results were evaluated by SPSS v. 14 program. In the transcription evaluation, units without a ward pharmacist did not improve. Transcription errors significantly decreased in three units: gynaecology-urology (3.24% vs. 0.52%), orthopaedic (2% vs. 1.69%) and neurology-pneumology (2.81% vs. 2.02%). In dispensing, only units with the new protocol decreased their medication errors (1.77% vs. 1.24%). The participation of pharmacists in multidisciplinary teams and exhaustive protocols for dispensing medication were effective in detecting and decreasing medication errors in patients.
Computerized N-acetylcysteine physician order entry by template protocol for acetaminophen toxicity.
Thompson, Trevonne M; Lu, Jenny J; Blackwood, Louisa; Leikin, Jerrold B
2011-01-01
Some medication dosing protocols are logistically complex for traditional physician ordering. The use of computerized physician order entry (CPOE) with templates, or order sets, may be useful to reduce medication administration errors. This study evaluated the rate of medication administration errors using CPOE order sets for N-acetylcysteine (NAC) use in treating acetaminophen poisoning. An 18-month retrospective review of computerized inpatient pharmacy records for NAC use was performed. All patients who received NAC for the treatment of acetaminophen poisoning were included. Each record was analyzed to determine the form of NAC given and whether an administration error occurred. In the 82 cases of acetaminophen poisoning in which NAC was given, no medication administration errors were identified. Oral NAC was given in 31 (38%) cases; intravenous NAC was given in 51 (62%) cases. In this retrospective analysis of N-acetylcysteine administration using computerized physician order entry and order sets, no medication administration errors occurred. CPOE is an effective tool in safely executing complicated protocols in an inpatient setting.
Cabilan, C J; Hughes, James A; Shannon, Carl
2017-12-01
To describe the contextual, modal and psychological classification of medication errors in the emergency department to know the factors associated with the reported medication errors. The causes of medication errors are unique in every clinical setting; hence, error minimisation strategies are not always effective. For this reason, it is fundamental to understand the causes specific to the emergency department so that targeted strategies can be implemented. Retrospective analysis of reported medication errors in the emergency department. All voluntarily staff-reported medication-related incidents from 2010-2015 from the hospital's electronic incident management system were retrieved for analysis. Contextual classification involved the time, place and the type of medications involved. Modal classification pertained to the stage and issue (e.g. wrong medication, wrong patient). Psychological classification categorised the errors in planning (knowledge-based and rule-based errors) and skill (slips and lapses). There were 405 errors reported. Most errors occurred in the acute care area, short-stay unit and resuscitation area, during the busiest shifts (0800-1559, 1600-2259). Half of the errors involved high-alert medications. Many of the errors occurred during administration (62·7%), prescribing (28·6%) and commonly during both stages (18·5%). Wrong dose, wrong medication and omission were the issues that dominated. Knowledge-based errors characterised the errors that occurred in prescribing and administration. The highest proportion of slips (79·5%) and lapses (76·1%) occurred during medication administration. It is likely that some of the errors occurred due to the lack of adherence to safety protocols. Technology such as computerised prescribing, barcode medication administration and reminder systems could potentially decrease the medication errors in the emergency department. There was a possibility that some of the errors could be prevented if safety protocols were adhered to, which highlights the need to also address clinicians' attitudes towards safety. Technology can be implemented to help minimise errors in the ED, but this must be coupled with efforts to enhance the culture of safety. © 2017 John Wiley & Sons Ltd.
Adherence with renal dosing recommendations in outpatients undergoing haemodialysis.
Kim, G J; Je, N K; Kim, D-S; Lee, S
2016-02-01
Adjustment of drug dosage in patients with end-stage renal disease prevents serious adverse effects, which occur due to the accumulation of drugs or other toxic metabolites. Nevertheless, dosing errors occur most commonly among patients with end-stage renal disease. The aim of this study was to assess the quality of care for end-stage renal disease outpatients using their renal dosing adjustment status. A cross-sectional study was performed using the data collected from 43 South Korean medical institutions via questionnaires. A total of 2428 patients on haemodialysis, who were at least 18 years of age, were included. Among these patients, the study population was confined to patients who were taking medications and required renal dosing adjustments from three therapeutic classes: antihypertensives, antihyperglycaemics and lipid-modifying agents. The study population (n = 828) was prescribed a total of 1097 drug orders for the target drugs. Determination of appropriate dosage adjustment was based on GFR (glomerular filtration rate) using the Modification of Diet in Renal Disease revised 4-variable equation. The primary outcome was non-adherence to drug dosing requirements for end-stage renal disease patients with consideration to their renal function. Among the study population (n = 828), 469 haemodialysis patients were identified as having drug orders that were adherent to renal dosing recommendations. There were significant differences between the patient groups who received recommendation-adherent and non-adherent drug orders in the characteristics of the medical institutions they visited, causes of chronic renal failure and prevalence of concurrent diabetes mellitus. The primary factor of non-adherence to renal dosing adjustment recommendations was characteristics of medical institutions. Compared to tertiary hospitals, secondary hospitals and primary care clinics were 1·16 and 1·22 times, respectively, more non-adherent in accordance with the multivariate analysis (OR: 1.16, 95% CI: 1.02-1.20, OR: 1.22, 95% CI: 1·00-1·36, respectively). Dosing error is one of the most common problems among patients with renal failure. To decrease the dosing errors, an improvement needs to be made in medical institutions. This can be accomplished by implementing the clinical decision support systems that educate physicians on appropriate renal dosing and help them prescribe appropriate drug dosages. © 2015 John Wiley & Sons Ltd.
Atik, Alp
2013-10-01
In 2006, the National Inpatient Medication Chart (NIMC) was introduced as a uniform medication chart in Australian public hospitals with the aim of reducing prescription error. The rate of regular medication prescription error in the NIMC was assessed. Data was collected using the NIMC Audit Tool and analyzed with respect to causes of error per medication prescription and per medication chart. The following prescription requirements were assessed: date, generic drug name, route of administration, dose, frequency, administration time, indication, signature, name and contact details. A total of 1877 medication prescriptions were reviewed. 1653 prescriptions (88.07%) had no contact number, 1630 (86.84%) did not have an indication, 1230 and 675 (35.96%) used a drug's trade name. Within 261 medication charts, all had at least one entry, which did not include an indication, 258 (98.85%) had at least one entry, which did not have a contact number and 200 (76.63%) had at least one entry, which used a trade name. The introduction of a uniform national medication chart is a positive step, but more needs to be done to address the root causes of prescription error. © 2012 John Wiley & Sons Ltd.
Decision Support Alerts for Medication Ordering in a Computerized Provider Order Entry (CPOE) System
Beccaro, M. A. Del; Villanueva, R.; Knudson, K. M.; Harvey, E. M.; Langle, J. M.; Paul, W.
2010-01-01
Objective We sought to determine the frequency and type of decision support alerts by location and ordering provider role during Computerized Provider Order Entry (CPOE) medication ordering. Using these data we adjusted the decision support tools to reduce the number of alerts. Design Retrospective analyses were performed of dose range checks (DRC), drug-drug interaction and drug-allergy alerts from our electronic medical record. During seven sampling periods (each two weeks long) between April 2006 and October 2008 all alerts in these categories were analyzed. Another audit was performed of all DRC alerts by ordering provider role from November 2008 through January 2009. Medication ordering error counts were obtained from a voluntary error reporting system. Measurement/Results Between April 2006 and October 2008 the percent of medication orders that triggered a dose range alert decreased from 23.9% to 7.4%. The relative risk (RR) for getting an alert was higher at the start of the interventions versus later (RR= 2.40, 95% CI 2.28-2.52; p< 0.0001). The percentage of medication orders that triggered alerts for drug-drug interactions also decreased from 13.5% to 4.8%. The RR for getting a drug interaction alert at the start was 1.63, 95% CI 1.60-1.66; p< 0.0001. Alerts decreased in all clinical areas without an increase in reported medication errors. Conclusion We reduced the quantity of decision support alerts in CPOE using a systematic approach without an increase in reported medication errors PMID:23616845
Medication errors in the obstetrics emergency ward in a low resource setting.
Kandil, Mohamed; Sayyed, Tarek; Emarh, Mohamed; Ellakwa, Hamed; Masood, Alaa
2012-08-01
To investigate the patterns of medication errors in the obstetric emergency ward in a low resource setting. This prospective observational study included 10,000 women who presented at the obstetric emergency ward, department of Obstetrics and Gynecology, Menofyia University Hospital, Egypt between March and December 2010. All medications prescribed in the emergency ward were monitored for different types of errors. The head nurse in each shift was asked to monitor each pharmacologic order from the moment of prescribing till its administration. Retrospective review of the patients' charts and nurses' notes was carried out by the authors of this paper. Results were tabulated and statistically analyzed. A total of 1976 medication errors were detected. Administration errors were the commonest error reported. Omitted errors ranked second followed by unauthorized and prescription errors. Three administration errors resulted in three Cesareans were performed for fetal distress because of wrong doses of oxytocin infusion. The rest of errors did not cause patients harm but may have lead to an increase in monitoring. Most errors occurred during night shifts. The availability of automated infusion pumps will probably decrease administration errors significantly. There is a need for more obstetricians and nurses during the nightshifts to minimize errors resulting from working under stressful conditions.
Ulas, Arife; Silay, Kamile; Akinci, Sema; Dede, Didem Sener; Akinci, Muhammed Bulent; Sendur, Mehmet Ali Nahit; Cubukcu, Erdem; Coskun, Hasan Senol; Degirmenci, Mustafa; Utkan, Gungor; Ozdemir, Nuriye; Isikdogan, Abdurrahman; Buyukcelik, Abdullah; Inanc, Mevlude; Bilici, Ahmet; Odabasi, Hatice; Cihan, Sener; Avci, Nilufer; Yalcin, Bulent
2015-01-01
Medication errors in oncology may cause severe clinical problems due to low therapeutic indices and high toxicity of chemotherapeutic agents. We aimed to investigate unintentional medication errors and underlying factors during chemotherapy preparation and administration based on a systematic survey conducted to reflect oncology nurses experience. This study was conducted in 18 adult chemotherapy units with volunteer participation of 206 nurses. A survey developed by primary investigators and medication errors (MAEs) defined preventable errors during prescription of medication, ordering, preparation or administration. The survey consisted of 4 parts: demographic features of nurses; workload of chemotherapy units; errors and their estimated monthly number during chemotherapy preparation and administration; and evaluation of the possible factors responsible from ME. The survey was conducted by face to face interview and data analyses were performed with descriptive statistics. Chi-square or Fisher exact tests were used for a comparative analysis of categorical data. Some 83.4% of the 210 nurses reported one or more than one error during chemotherapy preparation and administration. Prescribing or ordering wrong doses by physicians (65.7%) and noncompliance with administration sequences during chemotherapy administration (50.5%) were the most common errors. The most common estimated average monthly error was not following the administration sequence of the chemotherapeutic agents (4.1 times/month, range 1-20). The most important underlying reasons for medication errors were heavy workload (49.7%) and insufficient number of staff (36.5%). Our findings suggest that the probability of medication error is very high during chemotherapy preparation and administration, the most common involving prescribing and ordering errors. Further studies must address the strategies to minimize medication error in chemotherapy receiving patients, determine sufficient protective measures and establishing multistep control mechanisms.
A Spanish Pillbox App for Elderly Patients Taking Multiple Medications: Randomized Controlled Trial
Mira, José Joaquín; Navarro, Isabel; Botella, Federico; Borrás, Fernando; Orozco, Domingo; Iglesias-Alonso, Fuencisla; Pérez-Pérez, Pastora; Lorenzo, Susana; Toro, Nuria
2014-01-01
Background Nonadherence and medication errors are common among patients with complex drug regimens. Apps for smartphones and tablets are effective for improving adherence, but they have not been tested in elderly patients with complex chronic conditions and who typically have less experience with this type of technology. Objective The objective of this study was to design, implement, and evaluate a medication self-management app (called ALICE) for elderly patients taking multiple medications with the intention of improving adherence and safe medication use. Methods A single-blind randomized controlled trial was conducted with a control and an experimental group (N=99) in Spain in 2013. The characteristics of ALICE were specified based on the suggestions of 3 nominal groups with a total of 23 patients and a focus group with 7 professionals. ALICE was designed for Android and iOS to allow for the personalization of prescriptions and medical advice, showing images of each of the medications (the packaging and the medication itself) together with alerts and multiple reminders for each alert. The randomly assigned patients in the control group received oral and written information on the safe use of their medications and the patients in the experimental group used ALICE for 3 months. Pre and post measures included rate of missed doses and medication errors reported by patients, scores from the 4-item Morisky Medication Adherence Scale (MMAS-4), level of independence, self-perceived health status, and biochemical test results. In the experimental group, data were collected on their previous experience with information and communication technologies, their rating of ALICE, and their perception of the level of independence they had achieved. The intergroup intervention effects were calculated by univariate linear models and ANOVA, with the pre to post intervention differences as the dependent variables. Results Data were obtained from 99 patients (48 and 51 in the control and experimental groups, respectively). Patients in the experimental group obtained better MMAS-4 scores (P<.001) and reported fewer missed doses of medication (P=.02). ALICE only helped to significantly reduce medication errors in patients with an initially higher rate of errors (P<.001). Patients with no experience with information and communication technologies reported better adherence (P<.001), fewer missed doses (P<.001), and fewer medication errors (P=.02). The mean satisfaction score for ALICE was 8.5 out of 10. In all, 45 of 51 patients (88%) felt that ALICE improved their independence in managing their medications. Conclusions The ALICE app improves adherence, helps reduce rates of forgetting and of medication errors, and increases perceived independence in managing medication. Elderly patients with no previous experience with information and communication technologies are capable of effectively using an app designed to help them take their medicine more safely. Trial Registration Clinicaltrials.gov NCT02071498; http://clinicaltrials.gov/ct2/show/NCT02071498 (Archived by WebCite at http://www.webcitation.org/6OJjdHVhD). PMID:24705022
A Spanish pillbox app for elderly patients taking multiple medications: randomized controlled trial.
Mira, José Joaquín; Navarro, Isabel; Botella, Federico; Borrás, Fernando; Nuño-Solinís, Roberto; Orozco, Domingo; Iglesias-Alonso, Fuencisla; Pérez-Pérez, Pastora; Lorenzo, Susana; Toro, Nuria
2014-04-04
Nonadherence and medication errors are common among patients with complex drug regimens. Apps for smartphones and tablets are effective for improving adherence, but they have not been tested in elderly patients with complex chronic conditions and who typically have less experience with this type of technology. The objective of this study was to design, implement, and evaluate a medication self-management app (called ALICE) for elderly patients taking multiple medications with the intention of improving adherence and safe medication use. A single-blind randomized controlled trial was conducted with a control and an experimental group (N=99) in Spain in 2013. The characteristics of ALICE were specified based on the suggestions of 3 nominal groups with a total of 23 patients and a focus group with 7 professionals. ALICE was designed for Android and iOS to allow for the personalization of prescriptions and medical advice, showing images of each of the medications (the packaging and the medication itself) together with alerts and multiple reminders for each alert. The randomly assigned patients in the control group received oral and written information on the safe use of their medications and the patients in the experimental group used ALICE for 3 months. Pre and post measures included rate of missed doses and medication errors reported by patients, scores from the 4-item Morisky Medication Adherence Scale (MMAS-4), level of independence, self-perceived health status, and biochemical test results. In the experimental group, data were collected on their previous experience with information and communication technologies, their rating of ALICE, and their perception of the level of independence they had achieved. The intergroup intervention effects were calculated by univariate linear models and ANOVA, with the pre to post intervention differences as the dependent variables. Data were obtained from 99 patients (48 and 51 in the control and experimental groups, respectively). Patients in the experimental group obtained better MMAS-4 scores (P<.001) and reported fewer missed doses of medication (P=.02). ALICE only helped to significantly reduce medication errors in patients with an initially higher rate of errors (P<.001). Patients with no experience with information and communication technologies reported better adherence (P<.001), fewer missed doses (P<.001), and fewer medication errors (P=.02). The mean satisfaction score for ALICE was 8.5 out of 10. In all, 45 of 51 patients (88%) felt that ALICE improved their independence in managing their medications. The ALICE app improves adherence, helps reduce rates of forgetting and of medication errors, and increases perceived independence in managing medication. Elderly patients with no previous experience with information and communication technologies are capable of effectively using an app designed to help them take their medicine more safely. Clinicaltrials.gov NCT02071498; http://clinicaltrials.gov/ct2/show/NCT02071498.
Have a Baby or Young Child With a Cold? Most Don't Need Medicines
... With a Cough or Cold Don't Need Medicines Share Tweet Linkedin Pin it More sharing options ... the correct dose. Giving the Right Dose of Medicine “It’s easy to make errors with liquid medications. ...
Siemianowski, Laura A; Sen, Sanchita; George, Jomy M
2013-08-01
This study aimed to examine the role of a pharmacy technician-centered medication reconciliation (PTMR) program in optimization of medication therapy in hospitalized patients with HIV/AIDS. A chart review was conducted for all inpatients that had a medication reconciliation performed by the PTMR program. Adult patients with HIV and antiretroviral therapy (ART) and/or the opportunistic infection (OI) prophylaxis listed on the medication reconciliation form were included. The primary objective is to describe the (1) number and types of medication errors and (2) the percentage of patients who received appropriate ART. The secondary objective is a comparison of the number of medication errors between standard mediation reconciliation and a pharmacy-led program. In the PTMR period, 55 admissions were evaluated. In all, 50% of the patients received appropriate ART. In 27of the 55 admissions, there were 49 combined ART and OI-related errors. The most common ART-related errors were drug-drug interactions. The incidence of ART-related medication errors that included drug-drug interactions and renal dosing adjustments were similar between the pre-PTMR and PTMR groups (P = .0868). Of the 49 errors in the PTMR group, 18 were intervened by a medication reconciliation pharmacist. A PTMR program has a positive impact on optimizing ART and OI prophylaxis in patients with HIV/AIDS.
Comparison of medication safety effectiveness among nine critical access hospitals.
Cochran, Gary L; Haynatzki, Gleb
2013-12-15
The rates of medication errors across three different medication dispensing and administration systems frequently used in critical access hospitals (CAHs) were analyzed. Nine CAHs agreed to participate in this prospective study and were assigned to one of three groups based on similarities in their medication-use processes: (1) less than 10 hours per week of onsite pharmacy support and no bedside barcode system, (2) onsite pharmacy support for 40 hours per week and no bedside barcode system, and (3) onsite pharmacy support for 40 or more hours per week with a bedside barcode system. Errors were characterized by severity, phase of origination, type, and cause. Characteristics of the medication being administered and a number of best practices were collected for each medication pass. Logistic regression was used to identify significant predictors of errors. A total of 3103 medication passes were observed. More medication errors originated in hospitals that had onsite pharmacy support for less than 10 hours per week and no bedside barcode system than in other types of hospitals. A bedside barcode system had the greatest impact on lowering the odds of an error reaching the patient. Wrong dose and omission were common error types. Human factors and communication were the two most frequently identified causes of error for all three systems. Medication error rates were lower in CAHs with 40 or more hours per week of onsite pharmacy support with or without a bedside barcode system compared with hospitals with less than 10 hours per week of pharmacy support and no bedside barcode system.
Elsaid, K; Truong, T; Monckeberg, M; McCarthy, H; Butera, J; Collins, C
2013-12-01
To evaluate the impact of electronic standardized chemotherapy templates on incidence and types of prescribing errors. A quasi-experimental interrupted time series with segmented regression. A 700-bed multidisciplinary tertiary care hospital with an ambulatory cancer center. A multidisciplinary team including oncology physicians, nurses, pharmacists and information technologists. Standardized, regimen-specific, chemotherapy prescribing forms were developed and implemented over a 32-month period. Trend of monthly prevented prescribing errors per 1000 chemotherapy doses during the pre-implementation phase (30 months), immediate change in the error rate from pre-implementation to implementation and trend of errors during the implementation phase. Errors were analyzed according to their types: errors in communication or transcription, errors in dosing calculation and errors in regimen frequency or treatment duration. Relative risk (RR) of errors in the post-implementation phase (28 months) compared with the pre-implementation phase was computed with 95% confidence interval (CI). Baseline monthly error rate was stable with 16.7 prevented errors per 1000 chemotherapy doses. A 30% reduction in prescribing errors was observed with initiating the intervention. With implementation, a negative change in the slope of prescribing errors was observed (coefficient = -0.338; 95% CI: -0.612 to -0.064). The estimated RR of transcription errors was 0.74; 95% CI (0.59-0.92). The estimated RR of dosing calculation errors was 0.06; 95% CI (0.03-0.10). The estimated RR of chemotherapy frequency/duration errors was 0.51; 95% CI (0.42-0.62). Implementing standardized chemotherapy-prescribing templates significantly reduced all types of prescribing errors and improved chemotherapy safety.
Björkstén, Karin Sparring; Bergqvist, Monica; Andersén-Karlsson, Eva; Benson, Lina; Ulfvarson, Johanna
2016-08-24
Many studies address the prevalence of medication errors but few address medication errors serious enough to be regarded as malpractice. Other studies have analyzed the individual and system contributory factor leading to a medication error. Nurses have a key role in medication administration, and there are contradictory reports on the nurses' work experience in relation to the risk and type for medication errors. All medication errors where a nurse was held responsible for malpractice (n = 585) during 11 years in Sweden were included. A qualitative content analysis and classification according to the type and the individual and system contributory factors was made. In order to test for possible differences between nurses' work experience and associations within and between the errors and contributory factors, Fisher's exact test was used, and Cohen's kappa (k) was performed to estimate the magnitude and direction of the associations. There were a total of 613 medication errors in the 585 cases, the most common being "Wrong dose" (41 %), "Wrong patient" (13 %) and "Omission of drug" (12 %). In 95 % of the cases, an average of 1.4 individual contributory factors was found; the most common being "Negligence, forgetfulness or lack of attentiveness" (68 %), "Proper protocol not followed" (25 %), "Lack of knowledge" (13 %) and "Practice beyond scope" (12 %). In 78 % of the cases, an average of 1.7 system contributory factors was found; the most common being "Role overload" (36 %), "Unclear communication or orders" (30 %) and "Lack of adequate access to guidelines or unclear organisational routines" (30 %). The errors "Wrong patient due to mix-up of patients" and "Wrong route" and the contributory factors "Lack of knowledge" and "Negligence, forgetfulness or lack of attentiveness" were more common in less experienced nurses. The experienced nurses were more prone to "Practice beyond scope of practice" and to make errors in spite of "Lack of adequate access to guidelines or unclear organisational routines". Medication errors regarded as malpractice in Sweden were of the same character as medication errors worldwide. A complex interplay between individual and system factors often contributed to the errors.
Palmero, David; Di Paolo, Ermindo R; Beauport, Lydie; Pannatier, André; Tolsa, Jean-François
2016-01-01
The objective of this study was to assess whether the introduction of a new preformatted medical order sheet coupled with an introductory course affected prescription quality and the frequency of errors during the prescription stage in a neonatal intensive care unit (NICU). Two-phase observational study consisting of two consecutive 4-month phases: pre-intervention (phase 0) and post-intervention (phase I) conducted in an 11-bed NICU in a Swiss university hospital. Interventions consisted of the introduction of a new preformatted medical order sheet with explicit information supplied, coupled with a staff introductory course on appropriate prescription and medication errors. The main outcomes measured were formal aspects of prescription and frequency and nature of prescription errors. Eighty-three and 81 patients were included in phase 0 and phase I, respectively. A total of 505 handwritten prescriptions in phase 0 and 525 in phase I were analysed. The rate of prescription errors decreased significantly from 28.9% in phase 0 to 13.5% in phase I (p < 0.05). Compared with phase 0, dose errors, name confusion and errors in frequency and rate of drug administration decreased in phase I, from 5.4 to 2.7% (p < 0.05), 5.9 to 0.2% (p < 0.05), 3.6 to 0.2% (p < 0.05), and 4.7 to 2.1% (p < 0.05), respectively. The rate of incomplete and ambiguous prescriptions decreased from 44.2 to 25.7 and 8.5 to 3.2% (p < 0.05), respectively. Inexpensive and simple interventions can improve the intelligibility of prescriptions and reduce medication errors. Medication errors are frequent in NICUs and prescription is one of the most critical steps. CPOE reduce prescription errors, but their implementation is not available everywhere. Preformatted medical order sheet coupled with an introductory course decrease medication errors in a NICU. Preformatted medical order sheet is an inexpensive and readily implemented alternative to CPOE.
Glover, Mark L; Sussmane, Jeffrey B
2002-10-01
To evaluate residents' skills in performing basic mathematical calculations used for prescribing medications to pediatric patients. In 2001, a test of ten questions on basic calculations was given to first-, second-, and third-year residents at Miami Children's Hospital in Florida. Four additional questions were included to obtain the residents' levels of training, specific pediatrics intensive care unit (PICU) experience, and whether or not they routinely double-checked doses and adjusted them for each patient's weight. The test was anonymous and calculators were permitted. The overall score and the score for each resident class were calculated. Twenty-one residents participated. The overall average test score and the mean test score of each resident class was less than 70%. Second-year residents had the highest mean test scores, although there was no significant difference between the classes of residents (p =.745) or relationship between the residents' PICU experiences and their exam scores (p =.766). There was no significant difference between residents' levels of training and whether they double-checked their calculations (p =.633) or considered each patient's weight relative to the dose prescribed (p =.869). Seven residents committed tenfold dosing errors, and one resident committed a 1,000-fold dosing error. Pediatrics residents need to receive additional education in performing the calculations needed to prescribe medications. In addition, residents should be required to demonstrate these necessary mathematical skills before they are allowed to prescribe medications.
McQueen, Daniel S; Begg, Michael J; Maxwell, Simon R J
2010-10-01
Dose calculation errors can cause serious life-threatening clinical incidents. We designed eDrugCalc as an online self-assessment tool to develop and evaluate calculation skills among medical students. We undertook a prospective uncontrolled study involving 1727 medical students in years 1-5 at the University of Edinburgh. Students had continuous access to eDrugCalc and were encouraged to practise. Voluntary self-assessment was undertaken by answering the 20 questions on six occasions over 30 months. Questions remained fixed but numerical variables changed so each visit required a fresh calculation. Feedback was provided following each answer. Final-year students had a significantly higher mean score in test 6 compared with test 1 [16.6, 95% confidence interval (CI) 16.2, 17.0 vs. 12.6, 95% CI 11.9, 13.4; n= 173, P < 0.0001 Wilcoxon matched pairs test] and made a median of three vs. seven errors. Performance was highly variable in all tests with 2.7% of final-year students scoring < 10/20 in test 6. Graduating students in 2009 (30 months' exposure) achieved significantly better scores than those in 2007 (only 6 months): mean 16.5, 95% CI 16.0, 17.0, n= 184 vs. 15.1, 95% CI 14.5, 15.6, n= 187; P < 0.0001, Mann-Whitney test. Calculations based on percentage concentrations and infusion rates were poorly performed. Feedback showed that eDrugCalc increased confidence in calculating doses and was highly rated as a learning tool. Medical student performance of dose calculations improved significantly after repeated exposure to an online formative dose-calculation package and encouragement to develop their numeracy. Further research is required to establish whether eDrugCalc reduces calculation errors made in clinical practice. © 2010 The Authors. British Journal of Clinical Pharmacology © 2010 The British Pharmacological Society.
Medication reconciliation service in Tan Tock Seng Hospital.
Yi, Sia Beng; Shan, Janice Chan Pei; Hong, Goh Lay
2013-01-01
Medication reconciliation is integral to every hospital. Approximately 60 percent of all hospital medication errors occur at admission, intra-hospital transfer or discharge. Effectively and consistently performing medication reconciliation at care-interfaces continues to be a challenge. Tan Tock Seng Hospital (TTSH) averages 4,700 admissions monthly. Many patients are elderly (> 65 years old) at risk from poly-pharmacy. As part of a medication safety initiative, pharmacy staff started a medication reconciliation service in 2007, which expanded to include all patients in October 2009. This article aims to describe the TTSH medication reconciliation system and to highlight common medication errors occurring following incomplete medication reconciliation. Where possible, patients admitted into TTSH are seen by pharmacy staff within 24 hours of admission. A form was created to document their medications, which is filed into the case sheets for referencing purposes. Any discrepancies in medicines are brought to doctors' attention. Patients are also counseled about changes to their medications. Errors picked up were captured in an Excel database. The most common medication error was prescribers missing out medications. The second commonest was recording different doses and regimens. The reason was mainly due to doctors transcribing medications inaccurately. This is a descriptive study and no statistical tests were carried out. Data entry was done by different pharmacy staff, and not a dedicated person; hence, data might be under-reported. The findings demonstrate the importance of medication reconciliation on admission. Accurate medication reconciliation can help to reduce transcription errors and improve service quality. The article highlights medication reconciliation's importance and has implications for healthcare professionals in all countries.
2010 drug packaging review: identifying problems to prevent errors.
2011-06-01
Prescrire's analyses showed that the quality of drug packaging in 2010 still left much to be desired. Potentially dangerous packaging remains a significant problem: unclear labelling is source of medication errors; dosing devices for some psychotropic drugs create a risk of overdose; child-proof caps are often lacking; and too many patient information leaflets are misleading or difficult to understand. Everything that is needed for safe drug packaging is available; it is now up to regulatory agencies and drug companies to act responsibly. In the meantime, health professionals can help their patients by learning to identify the pitfalls of drug packaging and providing safe information to help prevent medication errors.
Medication Errors in Patients with Enteral Feeding Tubes in the Intensive Care Unit.
Sohrevardi, Seyed Mojtaba; Jarahzadeh, Mohammad Hossein; Mirzaei, Ehsan; Mirjalili, Mahtabalsadat; Tafti, Arefeh Dehghani; Heydari, Behrooz
2017-01-01
Most patients admitted to Intensive Care Units (ICU) have problems in using oral medication or ingesting solid forms of drugs. Selecting the most suitable dosage form in such patients is a challenge. The current study was conducted to assess the frequency and types of errors of oral medication administration in patients with enteral feeding tubes or suffering swallowing problems. A cross-sectional study was performed in the ICU of Shahid Sadoughi Hospital, Yazd, Iran. Patients were assessed for the incidence and types of medication errors occurring in the process of preparation and administration of oral medicines. Ninety-four patients were involved in this study and 10,250 administrations were observed. Totally, 4753 errors occurred among the studied patients. The most commonly used drugs were pantoprazole tablet, piracetam syrup, and losartan tablet. A total of 128 different types of drugs and nine different oral pharmaceutical preparations were prescribed for the patients. Forty-one (35.34%) out of 116 different solid drugs (except effervescent tablets and powders) could be substituted by liquid or injectable forms. The most common error was the wrong time of administration. Errors of wrong dose preparation and administration accounted for 24.04% and 25.31% of all errors, respectively. In this study, at least three-fourth of the patients experienced medication errors. The occurrence of these errors can greatly impair the quality of the patients' pharmacotherapy, and more attention should be paid to this issue.
Heneka, Nicole; Shaw, Tim; Rowett, Debra; Phillips, Jane L
2016-06-01
Opioids are the primary pharmacological treatment for cancer pain and, in the palliative care setting, are routinely used to manage symptoms at the end of life. Opioids are one of the most frequently reported drug classes in medication errors causing patient harm. Despite their widespread use, little is known about the incidence and impact of opioid medication errors in oncology and palliative care settings. To determine the incidence, types and impact of reported opioid medication errors in adult oncology and palliative care patient settings. A systematic review. Five electronic databases and the grey literature were searched from 1980 to August 2014. Empirical studies published in English, reporting data on opioid medication error incidence, types or patient impact, within adult oncology and/or palliative care services, were included. Popay's narrative synthesis approach was used to analyse data. Five empirical studies were included in this review. Opioid error incidence rate was difficult to ascertain as each study focussed on a single narrow area of error. The predominant error type related to deviation from opioid prescribing guidelines, such as incorrect dosing intervals. None of the included studies reported the degree of patient harm resulting from opioid errors. This review has highlighted the paucity of the literature examining opioid error incidence, types and patient impact in adult oncology and palliative care settings. Defining, identifying and quantifying error reporting practices for these populations should be an essential component of future oncology and palliative care quality and safety initiatives. © The Author(s) 2015.
Li, Qi; Melton, Kristin; Lingren, Todd; Kirkendall, Eric S; Hall, Eric; Zhai, Haijun; Ni, Yizhao; Kaiser, Megan; Stoutenborough, Laura; Solti, Imre
2014-01-01
Although electronic health records (EHRs) have the potential to provide a foundation for quality and safety algorithms, few studies have measured their impact on automated adverse event (AE) and medical error (ME) detection within the neonatal intensive care unit (NICU) environment. This paper presents two phenotyping AE and ME detection algorithms (ie, IV infiltrations, narcotic medication oversedation and dosing errors) and describes manual annotation of airway management and medication/fluid AEs from NICU EHRs. From 753 NICU patient EHRs from 2011, we developed two automatic AE/ME detection algorithms, and manually annotated 11 classes of AEs in 3263 clinical notes. Performance of the automatic AE/ME detection algorithms was compared to trigger tool and voluntary incident reporting results. AEs in clinical notes were double annotated and consensus achieved under neonatologist supervision. Sensitivity, positive predictive value (PPV), and specificity are reported. Twelve severe IV infiltrates were detected. The algorithm identified one more infiltrate than the trigger tool and eight more than incident reporting. One narcotic oversedation was detected demonstrating 100% agreement with the trigger tool. Additionally, 17 narcotic medication MEs were detected, an increase of 16 cases over voluntary incident reporting. Automated AE/ME detection algorithms provide higher sensitivity and PPV than currently used trigger tools or voluntary incident-reporting systems, including identification of potential dosing and frequency errors that current methods are unequipped to detect. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Shrank, William H; Parker, Ruth; Davis, Terry; Pandit, Anjali U; Knox, Joann P; Moraras, Pear; Rademaker, Alfred; Wolf, Michael S
2010-11-01
Medication errors are an important public health concern, and poor understanding of medication labels are a root cause. Research shows that labels are variable, of poor quality, and not patient-centered. No real-world trials have evaluated whether improved medication labels can affect appropriate medication use, adherence or health outcomes. We developed an evidence-based prescription label that addresses both content and format. The enhanced label includes a universal medication schedule (UMS) that standardizes the directions for use incorporating 1) standard time periods for administration (morning, noon, evening, and bedtime), 2) numeric vs. alpha characters, 3) 'carriage returns' to separate daily dose and 4) a graphic aid to visually depict dose and frequency. We will evaluate the effect of providing this label to randomly sampled patients who receive their care from free clinics, mobile vans and federally qualified health centers (FQHCs) in Northern Virginia. We will recruit patients with diabetes or hypertension; these patients will be randomly assigned to receive all of their medications with improved labels or to receive prescriptions with standard labels. The primary outcome will be the patient's ability to correctly demonstrate dosing instructions. Other outcomes include adherence, error rates and health outcomes. To our knowledge, this trial is the first to evaluate the effect of prescription label improvement on understanding, medication use and outcomes in a clinical setting. If successful, these findings could be implemented broadly to promote safe and appropriate medication use and to support evidence-based standards in the development of labels. Copyright © 2010 Elsevier Inc. All rights reserved.
Drug error in paediatric anaesthesia: current status and where to go now.
Anderson, Brian J
2018-06-01
Medication errors in paediatric anaesthesia and the perioperative setting continue to occur despite widespread recognition of the problem and published advice for reduction of this predicament at international, national, local and individual levels. Current literature was reviewed to ascertain drug error rates and to appraise causes and proposed solutions to reduce these errors. The medication error incidence remains high. There is documentation of reduction through identification of causes with consequent education and application of safety analytics and quality improvement programs in anaesthesia departments. Children remain at higher risk than adults because of additional complexities such as drug dose calculations, increased susceptibility to some adverse effects and changes associated with growth and maturation. Major improvements are best made through institutional system changes rather than a commitment to do better on the part of each practitioner. Medication errors in paediatric anaesthesia represent an important risk to children and most are avoidable. There is now an understanding of the genesis of adverse drug events and this understanding should facilitate the implementation of known effective countermeasures. An institution-wide commitment and strategy are the basis for a worthwhile and sustained improvement in medication safety.
Saad, Chadi Y; Fogel, Joshua; Rubinstein, Sofia
2018-03-01
Errors in drug dosing lead to poor patient outcomes and are common in patients with chronic kidney disease (CKD). Because the majority of patients with CKD are being treated by physicians specializing in internal medicine, we studied the awareness and knowledge that internal medicine resident trainees (IMRTs) have regarding the correct dosage of commonly used analgesic and neuropsychotropic medications for patients with CKD. We surveyed 353 IMRTs about their awareness of whether a medication needs dose adjustment in patients with CKD and knowledge for medication adjustment by level of glomerular filtration rate. There were high percentages for lack of awareness and knowledge. For analgesics, this lack of awareness/knowledge was highest for acetaminophen (awareness 83.0%, knowledge 90.9%). For neuropsychotropics, this was highest for paroxetine (awareness 74.5%, knowledge 91.5%). Analyses for postgraduate year (PGY) -1 trainees and PGY-2 trainees for analgesics showed higher odds for lack of awareness for tramadol (PGY-1 odds ratio [OR] 2.37, 95% confidence interval [CI] 1.2-4.62, P < 0.05; PGY-2 OR 2.34, 95% CI 1.16-4.72, P < 0.05) and for lack of knowledge for meperedine (PGY-1 OR 4.01, 95% CI 1.81-8.89, P < 0.05; PGY-2 OR 3.30, 95% CI 1.44-7.59, P < 0.05). Nephrology residency rotation for the neuropsychotropic medication of gabapentin showed lower odds for both lack of awareness (OR 0.56, 95% CI 0.32-0.97, P < 0.05) and knowledge (OR 0.52, 95% CI 0.27-0.997, P < 0.05). Awareness and knowledge are poor among IMRTs for dose adjustments of analgesics and neuropsychotropic medication classes in patients with CKD. There should be a renewed focus during IMRTs' residency on additional nephrology exposure and formal didactic educational training to help them better manage complex treatment regimens to prevent medication dosing errors.
The Effects of Bar-coding Technology on Medication Errors: A Systematic Literature Review.
Hutton, Kevin; Ding, Qian; Wellman, Gregory
2017-02-24
The bar-coding technology adoptions have risen drastically in U.S. health systems in the past decade. However, few studies have addressed the impact of bar-coding technology with strong prospective methodologies and the research, which has been conducted from both in-pharmacy and bedside implementations. This systematic literature review is to examine the effectiveness of bar-coding technology on preventing medication errors and what types of medication errors may be prevented in the hospital setting. A systematic search of databases was performed from 1998 to December 2016. Studies measuring the effect of bar-coding technology on medication errors were included in a full-text review. Studies with the outcomes other than medication errors such as efficiency or workarounds were excluded. The outcomes were measured and findings were summarized for each retained study. A total of 2603 articles were initially identified and 10 studies, which used prospective before-and-after study design, were fully reviewed in this article. Of the 10 included studies, 9 took place in the United States, whereas the remaining was conducted in the United Kingdom. One research article focused on bar-coding implementation in a pharmacy setting, whereas the other 9 focused on bar coding within patient care areas. All 10 studies showed overall positive effects associated with bar-coding implementation. The results of this review show that bar-coding technology may reduce medication errors in hospital settings, particularly on preventing targeted wrong dose, wrong drug, wrong patient, unauthorized drug, and wrong route errors.
SU-E-T-503: IMRT Optimization Using Monte Carlo Dose Engine: The Effect of Statistical Uncertainty.
Tian, Z; Jia, X; Graves, Y; Uribe-Sanchez, A; Jiang, S
2012-06-01
With the development of ultra-fast GPU-based Monte Carlo (MC) dose engine, it becomes clinically realistic to compute the dose-deposition coefficients (DDC) for IMRT optimization using MC simulation. However, it is still time-consuming if we want to compute DDC with small statistical uncertainty. This work studies the effects of the statistical error in DDC matrix on IMRT optimization. The MC-computed DDC matrices are simulated here by adding statistical uncertainties at a desired level to the ones generated with a finite-size pencil beam algorithm. A statistical uncertainty model for MC dose calculation is employed. We adopt a penalty-based quadratic optimization model and gradient descent method to optimize fluence map and then recalculate the corresponding actual dose distribution using the noise-free DDC matrix. The impacts of DDC noise are assessed in terms of the deviation of the resulted dose distributions. We have also used a stochastic perturbation theory to theoretically estimate the statistical errors of dose distributions on a simplified optimization model. A head-and-neck case is used to investigate the perturbation to IMRT plan due to MC's statistical uncertainty. The relative errors of the final dose distributions of the optimized IMRT are found to be much smaller than those in the DDC matrix, which is consistent with our theoretical estimation. When history number is decreased from 108 to 106, the dose-volume-histograms are still very similar to the error-free DVHs while the error in DDC is about 3.8%. The results illustrate that the statistical errors in the DDC matrix have a relatively small effect on IMRT optimization in dose domain. This indicates we can use relatively small number of histories to obtain the DDC matrix with MC simulation within a reasonable amount of time, without considerably compromising the accuracy of the optimized treatment plan. This work is supported by Varian Medical Systems through a Master Research Agreement. © 2012 American Association of Physicists in Medicine.
Parental language and dosing errors after discharge from the pediatric emergency department.
Samuels-Kalow, Margaret E; Stack, Anne M; Porter, Stephen C
2013-09-01
Safe and effective care after discharge requires parental education in the pediatric emergency department (ED). Parent-provider communication may be more difficult with parents who have limited health literacy or English-language fluency. This study examined the relationship between language and discharge comprehension regarding medication dosing. We completed a prospective observational study of the ED discharge process using a convenience sample of English- and Spanish-speaking parents of children 2 to 24 months presenting to a single tertiary care pediatric ED with fever and/or respiratory illness. A bilingual research assistant interviewed parents to ascertain their primary language and health literacy and observed the discharge process. The primary outcome was parental demonstration of an incorrect dose of acetaminophen for the weight of his or her child. A total of 259 parent-child dyads were screened. There were 210 potential discharges, and 145 (69%) of 210 completed the postdischarge interview. Forty-six parents (32%) had an acetaminophen dosing error. Spanish-speaking parents were significantly more likely to have a dosing error (odds ratio, 3.7; 95% confidence interval, 1.6-8.1), even after adjustment for language of discharge, income, and parental health literacy (adjusted odds ratio, 6.7; 95% confidence interval, 1.4-31.7). Current ED discharge communication results in a significant disparity between English- and Spanish-speaking parents' comprehension of a crucial aspect of medication safety. These differences were not explained purely by interpretation, suggesting that interventions to improve comprehension must address factors beyond language alone.
Uy, Raymonde Charles Y; Kury, Fabricio P; Fontelo, Paul A
2015-01-01
The standard of safe medication practice requires strict observance of the five rights of medication administration: the right patient, drug, time, dose, and route. Despite adherence to these guidelines, medication errors remain a public health concern that has generated health policies and hospital processes that leverage automation and computerization to reduce these errors. Bar code, RFID, biometrics and pharmacy automation technologies have been demonstrated in literature to decrease the incidence of medication errors by minimizing human factors involved in the process. Despite evidence suggesting the effectivity of these technologies, adoption rates and trends vary across hospital systems. The objective of study is to examine the state and adoption trends of automatic identification and data capture (AIDC) methods and pharmacy automation technologies in U.S. hospitals. A retrospective descriptive analysis of survey data from the HIMSS Analytics® Database was done, demonstrating an optimistic growth in the adoption of these patient safety solutions.
Using snowball sampling method with nurses to understand medication administration errors.
Sheu, Shuh-Jen; Wei, Ien-Lan; Chen, Ching-Huey; Yu, Shu; Tang, Fu-In
2009-02-01
We aimed to encourage nurses to release information about drug administration errors to increase understanding of error-related circumstances and to identify high-alert situations. Drug administration errors represent the majority of medication errors, but errors are underreported. Effective ways are lacking to encourage nurses to actively report errors. Snowball sampling was conducted to recruit participants. A semi-structured questionnaire was used to record types of error, hospital and nurse backgrounds, patient consequences, error discovery mechanisms and reporting rates. Eighty-five nurses participated, reporting 328 administration errors (259 actual, 69 near misses). Most errors occurred in medical surgical wards of teaching hospitals, during day shifts, committed by nurses working fewer than two years. Leading errors were wrong drugs and doses, each accounting for about one-third of total errors. Among 259 actual errors, 83.8% resulted in no adverse effects; among remaining 16.2%, 6.6% had mild consequences and 9.6% had serious consequences (severe reaction, coma, death). Actual errors and near misses were discovered mainly through double-check procedures by colleagues and nurses responsible for errors; reporting rates were 62.5% (162/259) vs. 50.7% (35/69) and only 3.5% (9/259) vs. 0% (0/69) were disclosed to patients and families. High-alert situations included administration of 15% KCl, insulin and Pitocin; using intravenous pumps; and implementation of cardiopulmonary resuscitation (CPR). Snowball sampling proved to be an effective way to encourage nurses to release details concerning medication errors. Using empirical data, we identified high-alert situations. Strategies for reducing drug administration errors by nurses are suggested. Survey results suggest that nurses should double check medication administration in known high-alert situations. Nursing management can use snowball sampling to gather error details from nurses in a non-reprimanding atmosphere, helping to establish standard operational procedures for known high-alert situations.
Development and Assessment of a Medication Safety Measurement Program in a Long-Term Care Pharmacy.
Hertig, John B; Hultgren, Kyle E; Parks, Scott; Rondinelli, Rick
2016-02-01
Medication errors continue to be a major issue in the health care system, including in long-term care facilities. While many hospitals and health systems have developed methods to identify, track, and prevent these errors, long-term care facilities historically have not invested in these error-prevention strategies. The objective of this study was two-fold: 1) to develop a set of medication-safety process measures for dispensing in a long-term care pharmacy, and 2) to analyze the data from those measures to determine the relative safety of the process. The study was conducted at In Touch Pharmaceuticals in Valparaiso, Indiana. To assess the safety of the medication-use system, each step was documented using a comprehensive flowchart (process flow map) tool. Once completed and validated, the flowchart was used to complete a "failure modes and effects analysis" (FMEA) identifying ways a process may fail. Operational gaps found during FMEA were used to identify points of measurement. The research identified a set of eight measures as potential areas of failure; data were then collected on each one of these. More than 133,000 medication doses (opportunities for errors) were included in the study during the research time frame (April 1, 2014, and ended on June 4, 2014). Overall, there was an approximate order-entry error rate of 15.26%, with intravenous errors at 0.37%. A total of 21 errors migrated through the entire medication-use system. These 21 errors in 133,000 opportunities resulted in a final check error rate of 0.015%. A comprehensive medication-safety measurement program was designed and assessed. This study demonstrated the ability to detect medication errors in a long-term pharmacy setting, thereby making process improvements measureable. Future, larger, multi-site studies should be completed to test this measurement program.
Michaelson, M; Walsh, E; Bradley, C P; McCague, P; Owens, R; Sahm, L J
2017-08-01
Prescribing error may result in adverse clinical outcomes leading to increased patient morbidity, mortality and increased economic burden. Many errors occur during transitional care as patients move between different stages and settings of care. To conduct a review of medication information and identify prescribing error among an adult population in an urban hospital. Retrospective review of medication information was conducted. Part 1: an audit of discharge prescriptions which assessed: legibility, compliance with legal requirements, therapeutic errors (strength, dose and frequency) and drug interactions. Part 2: A review of all sources of medication information (namely pre-admission medication list, drug Kardex, discharge prescription, discharge letter) for 15 inpatients to identify unintentional prescription discrepancies, defined as: "undocumented and/or unjustified medication alteration" throughout the hospital stay. Part 1: of the 5910 prescribed items; 53 (0.9%) were deemed illegible. Of the controlled drug prescriptions 11.1% (n = 167) met all the legal requirements. Therapeutic errors occurred in 41% of prescriptions (n = 479) More than 1 in 5 patients (21.9%) received a prescription containing a drug interaction. Part 2: 175 discrepancies were identified across all sources of medication information; of which 78 were deemed unintentional. Of these: 10.2% (n = 8) occurred at the point of admission, whereby 76.9% (n = 60) occurred at the point of discharge. The study identified the time of discharge as a point at which prescribing errors are likely to occur. This has implications for patient safety and provider work load in both primary and secondary care.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellefson, S; Department of Human Oncology, University of Wisconsin, Madison, WI; Culberson, W
Purpose: Discrepancies in absolute dose values have been detected between the ViewRay treatment planning system and ArcCHECK readings when performing delivery quality assurance on the ViewRay system with the ArcCHECK-MR diode array (SunNuclear Corporation). In this work, we investigate whether these discrepancies are due to errors in the ViewRay planning and/or delivery system or due to errors in the ArcCHECK’s readings. Methods: Gamma analysis was performed on 19 ViewRay patient plans using the ArcCHECK. Frequency analysis on the dose differences was performed. To investigate whether discrepancies were due to measurement or delivery error, 10 diodes in low-gradient dose regions weremore » chosen to compare with ion chamber measurements in a PMMA phantom with the same size and shape as the ArcCHECK, provided by SunNuclear. The diodes chosen all had significant discrepancies in absolute dose values compared to the ViewRay TPS. Absolute doses to PMMA were compared between the ViewRay TPS calculations, ArcCHECK measurements, and measurements in the PMMA phantom. Results: Three of the 19 patient plans had 3%/3mm gamma passing rates less than 95%, and ten of the 19 plans had 2%/2mm passing rates less than 95%. Frequency analysis implied a non-random error process. Out of the 10 diode locations measured, ion chamber measurements were all within 2.2% error relative to the TPS and had a mean error of 1.2%. ArcCHECK measurements ranged from 4.5% to over 15% error relative to the TPS and had a mean error of 8.0%. Conclusion: The ArcCHECK performs well for quality assurance on the ViewRay under most circumstances. However, under certain conditions the absolute dose readings are significantly higher compared to the planned doses. As the ion chamber measurements consistently agree with the TPS, it can be concluded that the discrepancies are due to ArcCHECK measurement error and not TPS or delivery system error. This work was funded by the Bhudatt Paliwal Professorship and the University of Wisconsin Medical Radiation Research Center.« less
Common errors of drug administration in infants: causes and avoidance.
Anderson, B J; Ellis, J F
1999-01-01
Drug administration errors are common in infants. Although the infant population has a high exposure to drugs, there are few data concerning pharmacokinetics or pharmacodynamics, or the influence of paediatric diseases on these processes. Children remain therapeutic orphans. Formulations are often suitable only for adults; in addition, the lack of maturation of drug elimination processes, alteration of body composition and influence of size render the calculation of drug doses complex in infants. The commonest drug administration error in infants is one of dose, and the commonest hospital site for this error is the intensive care unit. Drug errors are a consequence of system error, and preventive strategies are possible through system analysis. The goal of a zero drug error rate should be aggressively sought, with systems in place that aim to eliminate the effects of inevitable human error. This involves review of the entire system from drug manufacture to drug administration. The nuclear industry, telecommunications and air traffic control services all practise error reduction policies with zero error as a clear goal, not by finding fault in the individual, but by identifying faults in the system and building into that system mechanisms for picking up faults before they occur. Such policies could be adapted to medicine using interventions both specific (the production of formulations which are for children only and clearly labelled, regular audit by pharmacists, legible prescriptions, standardised dose tables) and general (paediatric drug trials, education programmes, nonpunitive error reporting) to reduce the number of errors made in giving medication to infants.
[Knowledge of nurses about medication doses at pediatric urgency departament].
Guerrero-Márquez, Gloria; Martínez-Serrano, Ana; Míguez-Navarro, Concepción; López-Mirón, Juan Antonio; Espartosa-Larrayad, Marta
2016-01-01
Errors in drug administration are the second cause of errors in hospitalized patients. Children are a high risk group. Besides, pressure in care interventions at emergency department leads to increase incidence errors. Determining nurses' knowledge about the most common drug doses at pediatric urgency department. Descriptive transversal study. We collected data from nurses of 14 pediatric emergency departments of Madrid. With an "ad hoc" questionnaire we collected the following data during five days in January of 2014: demographic, knowledge of responsibility in administration and doses of drugs. Global descriptive analysis was made and it was stratified by hospital and work experience. The answer rate was 114 (34.9%). Only 80 (70.8%) of nurses confirm doses before their administration; 20 (18.6%) think that a wrong prescription that they administer is not their responsibility. There is a high knowledge in the group with more than five years of work experience, except for sedative-analgesic drugs (p<0.05). The average score obtained was 3.8 of 10 (1.99). Nurses' knowledge about drug doses is low. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Echeta, Genevieve; Moffett, Brady S; Checchia, Paul; Benton, Mary Kay; Klouda, Leda; Rodriguez, Fred H; Franklin, Wayne
2014-01-01
Adults with congenital heart disease (CHD) are often cared for at pediatric hospitals. There are no data describing the incidence or type of medication prescribing errors in adult patients admitted to a pediatric cardiovascular intensive care unit (CVICU). A review of patients >18 years of age admitted to the pediatric CVICU at our institution from 2009 to 2011 occurred. A comparator group <18 years of age but >70 kg (a typical adult weight) was identified. Medication prescribing errors were determined according to a commonly used adult drug reference. An independent panel consisting of a physician specializing in the care of adult CHD patients, a nurse, and a pharmacist evaluated all errors. Medication prescribing orders were classified as appropriate, underdose, overdose, or nonstandard (dosing per weight instead of standard adult dosing), and severity of error was classified. Eighty-five adult (74 patients) and 33 pediatric admissions (32 patients) met study criteria (mean age 27.5 ± 9.4 years, 53% male vs. 14.9 ± 1.8 years, 63% male). A cardiothoracic surgical procedure occurred in 81.4% of admissions. Adult admissions weighed less than pediatric admissions (72.8 ± 22.4 kg vs. 85.6 ± 14.9 kg, P < .01) but hospital length of stay was similar. (Adult 6 days [range 1-216 days]; pediatric 5 days [Range 2-123 days], P = .52.) A total of 112 prescribing errors were identified and they occurred less often in adults (42.4% of admissions vs. 66.7% of admissions, P = .02). Adults had a lower mean number of errors (0.7 errors per adult admission vs. 1.7 errors per pediatric admission, P < .01). Prescribing errors occurred most commonly with antimicrobials (n = 27). Underdosing was the most common category of prescribing error. Most prescribing errors were determined to have not caused harm to the patient. Prescribing errors occur frequently in adult patients admitted to a pediatric CVICU but occur more often in pediatric patients of adult weight. © 2013 Wiley Periodicals, Inc.
Oldland, Alan R.; May, Sondra K.; Barber, Gerard R.; Stolpman, Nancy M.
2015-01-01
Purpose: To measure the effects associated with sequential implementation of electronic medication storage and inventory systems and product verification devices on pharmacy technical accuracy and rates of potential medication dispensing errors in an academic medical center. Methods: During four 28-day periods of observation, pharmacists recorded all technical errors identified at the final visual check of pharmaceuticals prior to dispensing. Technical filling errors involving deviations from order-specific selection of product, dosage form, strength, or quantity were documented when dispensing medications using (a) a conventional unit dose (UD) drug distribution system, (b) an electronic storage and inventory system utilizing automated dispensing cabinets (ADCs) within the pharmacy, (c) ADCs combined with barcode (BC) verification, and (d) ADCs and BC verification utilized with changes in product labeling and individualized personnel training in systems application. Results: Using a conventional UD system, the overall incidence of technical error was 0.157% (24/15,271). Following implementation of ADCs, the comparative overall incidence of technical error was 0.135% (10/7,379; P = .841). Following implementation of BC scanning, the comparative overall incidence of technical error was 0.137% (27/19,708; P = .729). Subsequent changes in product labeling and intensified staff training in the use of BC systems was associated with a decrease in the rate of technical error to 0.050% (13/26,200; P = .002). Conclusions: Pharmacy ADCs and BC systems provide complementary effects that improve technical accuracy and reduce the incidence of potential medication dispensing errors if this technology is used with comprehensive personnel training. PMID:25684799
Oldland, Alan R; Golightly, Larry K; May, Sondra K; Barber, Gerard R; Stolpman, Nancy M
2015-01-01
To measure the effects associated with sequential implementation of electronic medication storage and inventory systems and product verification devices on pharmacy technical accuracy and rates of potential medication dispensing errors in an academic medical center. During four 28-day periods of observation, pharmacists recorded all technical errors identified at the final visual check of pharmaceuticals prior to dispensing. Technical filling errors involving deviations from order-specific selection of product, dosage form, strength, or quantity were documented when dispensing medications using (a) a conventional unit dose (UD) drug distribution system, (b) an electronic storage and inventory system utilizing automated dispensing cabinets (ADCs) within the pharmacy, (c) ADCs combined with barcode (BC) verification, and (d) ADCs and BC verification utilized with changes in product labeling and individualized personnel training in systems application. Using a conventional UD system, the overall incidence of technical error was 0.157% (24/15,271). Following implementation of ADCs, the comparative overall incidence of technical error was 0.135% (10/7,379; P = .841). Following implementation of BC scanning, the comparative overall incidence of technical error was 0.137% (27/19,708; P = .729). Subsequent changes in product labeling and intensified staff training in the use of BC systems was associated with a decrease in the rate of technical error to 0.050% (13/26,200; P = .002). Pharmacy ADCs and BC systems provide complementary effects that improve technical accuracy and reduce the incidence of potential medication dispensing errors if this technology is used with comprehensive personnel training.
Prevalence and pattern of prescription errors in a Nigerian kidney hospital.
Babatunde, Kehinde M; Akinbodewa, Akinwumi A; Akinboye, Ayodele O; Adejumo, Ademola O
2016-12-01
To determine (i) the prevalence and pattern of prescription errors in our Centre and, (ii) appraise pharmacists' intervention and correction of identified prescription errors. A descriptive, single blinded cross-sectional study. Kidney Care Centre is a public Specialist hospital. The monthly patient load averages 60 General Out-patient cases and 17.4 in-patients. A total of 31 medical doctors (comprising of 2 Consultant Nephrologists, 15 Medical Officers, 14 House Officers), 40 nurses and 24 ward assistants participated in the study. One pharmacist runs the daily call schedule. Prescribers were blinded to the study. Prescriptions containing only galenicals were excluded. An error detection mechanism was set up to identify and correct prescription errors. Life-threatening prescriptions were discussed with the Quality Assurance Team of the Centre who conveyed such errors to the prescriber without revealing the on-going study. Prevalence of prescription errors, pattern of prescription errors, pharmacist's intervention. A total of 2,660 (75.0%) combined prescription errors were found to have one form of error or the other; illegitimacy 1,388 (52.18%), omission 1,221(45.90%), wrong dose 51(1.92%) and no error of style was detected. Life-threatening errors were low (1.1-2.2%). Errors were found more commonly among junior doctors and non-medical doctors. Only 56 (1.6%) of the errors were detected and corrected during the process of dispensing. Prescription errors related to illegitimacy and omissions were highly prevalent. There is a need to improve on patient-to-healthcare giver ratio. A medication quality assurance unit is needed in our hospitals. No financial support was received by any of the authors for this study.
Issues of medication administration and control in Iowa schools.
Farris, Karen B; McCarthy, Ann Marie; Kelly, Michael W; Clay, Daniel; Gross, Jami N
2003-11-01
Who is responsible for medication administration at school? To answer this question, a descriptive, self-administered survey was mailed to a random sample of 850 school principals in Iowa. The eight-page, 57-item, anonymous survey was mailed first class, and a follow-up reminder post card was mailed two weeks later. Descriptive analyses were conducted, with type of respondent (principal versus school nurse), grade level, and size of school examined to explore differences. A 46.6% response rate was obtained; 97% of respondents indicated their schools had written guidelines for medication administration. Principals (41%) and school nurses (34%) reported that they have the ultimate legal responsibility for medication administration. Policies for medication administration on field trips were available in schools of 73.6% of respondents. High schools were more likely to allow self-medication than other grade levels. "Missed dose" was the most common medication error. The main reasons contributing to medication administration errors included poor communication among school, family, and healthcare providers, and the increased number of students on medication. It remains unclear who holds ultimate responsibility for medication administration in schools. Written policies typically exist for medication administration at school, but not field trips. Communicating medication changes to schools, and ensuring medications are available at school, likely can reduce medication administration errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, R; Kamima, T; Tachibana, H
2016-06-15
Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dosemore » deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
Medication errors: definitions and classification
Aronson, Jeffrey K
2009-01-01
To understand medication errors and to identify preventive strategies, we need to classify them and define the terms that describe them. The four main approaches to defining technical terms consider etymology, usage, previous definitions, and the Ramsey–Lewis method (based on an understanding of theory and practice). A medication error is ‘a failure in the treatment process that leads to, or has the potential to lead to, harm to the patient’. Prescribing faults, a subset of medication errors, should be distinguished from prescription errors. A prescribing fault is ‘a failure in the prescribing [decision-making] process that leads to, or has the potential to lead to, harm to the patient’. The converse of this, ‘balanced prescribing’ is ‘the use of a medicine that is appropriate to the patient's condition and, within the limits created by the uncertainty that attends therapeutic decisions, in a dosage regimen that optimizes the balance of benefit to harm’. This excludes all forms of prescribing faults, such as irrational, inappropriate, and ineffective prescribing, underprescribing and overprescribing. A prescription error is ‘a failure in the prescription writing process that results in a wrong instruction about one or more of the normal features of a prescription’. The ‘normal features’ include the identity of the recipient, the identity of the drug, the formulation, dose, route, timing, frequency, and duration of administration. Medication errors can be classified, invoking psychological theory, as knowledge-based mistakes, rule-based mistakes, action-based slips, and memory-based lapses. This classification informs preventive strategies. PMID:19594526
Preliminary results of 3D dose calculations with MCNP-4B code from a SPECT image.
Rodríguez Gual, M; Lima, F F; Sospedra Alfonso, R; González González, J; Calderón Marín, C
2004-01-01
Interface software was developed to generate the input file to run Monte Carlo MCNP-4B code from medical image in Interfile format version 3.3. The software was tested using a spherical phantom of tomography slides with known cumulated activity distribution in Interfile format generated with IMAGAMMA medical image processing system. The 3D dose calculation obtained with Monte Carlo MCNP-4B code was compared with the voxel S factor method. The results show a relative error between both methods less than 1 %.
Horri, J; Cransac, A; Quantin, C; Abrahamowicz, M; Ferdynus, C; Sgro, C; Robillard, P-Y; Iacobelli, S; Gouyon, J-B
2014-12-01
The risk of dosage Prescription Medication Error (PME) among manually written prescriptions within 'mixed' prescribing system (computerized physician order entry (CPOE) + manual prescriptions) has not been previously assessed in neonatology. This study aimed to evaluate the rate of dosage PME related to manual prescriptions in the high-risk population of very preterm infants (GA < 33 weeks) in a mixed prescription system. The study was based on a retrospective review of a random sample of manual daily prescriptions in two neonatal intensive care units (NICU) A and B, located in different French University hospitals (Dijon and La Reunion island). Daily prescription was defined as the set of all drugs manually prescribed on a single day for one patient. Dosage error was defined as a deviation of at least ±10% from the weight-appropriate recommended dose. The analyses were based on the assessment of 676 manually prescribed drugs from NICU A (58 different drugs from 93 newborns and 240 daily prescriptions) and 354 manually prescribed drugs from NICU B (73 different drugs from 131 newborns and 241 daily prescriptions). The dosage error rate per 100 manually prescribed drugs was similar in both NICU: 3·8% (95% CI: 2·5-5·6%) in NICU A and 3·1% (95% CI: 1·6-5·5%) in NICU B (P = 0·54). Among all the 37 identified dosage errors, the over-dosing was almost as frequent as the under-dosing (17 and 20 errors, respectively). Potentially severe dosage errors occurred in a total of seven drug prescriptions. None of the dosage PME was recorded in the corresponding medical files and information on clinical outcome was not sufficient to identify clinical conditions related to dosage PME. Overall, 46·8% of manually prescribed drugs were off label or unlicensed, with no significant differences between prescriptions with or without dosage error. The risk of a dosage PME increased significantly if the drug was included in the CPOE system but was manually prescribed (OR = 3·3; 95% CI: 1·6-7·0, P < 0·001). The presence of dosage PME in the manual prescriptions written within mixed prescription systems suggests that manual prescriptions should be totally avoided in neonatal units. © 2014 John Wiley & Sons Ltd.
Cohen, Michael R.; Smetzer, Judy L.
2014-01-01
These medication errors have occurred in health care facilities at least once. They will happen again—perhaps where you work. Through education and alertness of personnel and procedural safeguards, they can be avoided. You should consider publishing accounts of errors in your newsletters and/or presenting them at your inservice training programs. Your assistance is required to continue this feature. The reports described here were received through the Institute for Safe Medication Practices (ISMP) Medication Errors Reporting Program. Any reports published by ISMP will be anonymous. Comments are also invited; the writers’ names will be published if desired. ISMP may be contacted at the address shown below. Errors, close calls, or hazardous conditions may be reported directly to ISMP through the ISMP Web site (www.ismp.org), by calling 800-FAIL-SAFE, or via e-mail at ismpinfo@ismp.org. ISMP guarantees the confidentiality and security of the information received and respects reporters’ wishes as to the level of detail included in publications. PMID:25477591
Medication-related clinical decision support in computerized provider order entry systems: a review.
Kuperman, Gilad J; Bobb, Anne; Payne, Thomas H; Avery, Anthony J; Gandhi, Tejal K; Burns, Gerard; Classen, David C; Bates, David W
2007-01-01
While medications can improve patients' health, the process of prescribing them is complex and error prone, and medication errors cause many preventable injuries. Computer provider order entry (CPOE) with clinical decision support (CDS), can improve patient safety and lower medication-related costs. To realize the medication-related benefits of CDS within CPOE, one must overcome significant challenges. Healthcare organizations implementing CPOE must understand what classes of CDS their CPOE systems can support, assure that clinical knowledge underlying their CDS systems is reasonable, and appropriately represent electronic patient data. These issues often influence to what extent an institution will succeed with its CPOE implementation and achieve its desired goals. Medication-related decision support is probably best introduced into healthcare organizations in two stages, basic and advanced. Basic decision support includes drug-allergy checking, basic dosing guidance, formulary decision support, duplicate therapy checking, and drug-drug interaction checking. Advanced decision support includes dosing support for renal insufficiency and geriatric patients, guidance for medication-related laboratory testing, drug-pregnancy checking, and drug-disease contraindication checking. In this paper, the authors outline some of the challenges associated with both basic and advanced decision support and discuss how those challenges might be addressed. The authors conclude with summary recommendations for delivering effective medication-related clinical decision support addressed to healthcare organizations, application and knowledge base vendors, policy makers, and researchers.
Home medication support for childhood cancer: family-centered design and testing.
Walsh, Kathleen E; Biggins, Colleen; Blasko, Deb; Christiansen, Steven M; Fischer, Shira H; Keuker, Christopher; Klugman, Robert; Mazor, Kathleen M
2014-11-01
Errors in the use of medications at home by children with cancer are common, and interventions to support correct use are needed. We sought to (1) engage stakeholders in the design and development of an intervention to prevent errors in home medication use, and (2) evaluate the acceptability and usefulness of the intervention. We convened a multidisciplinary team of parents, clinicians, technology experts, and researchers to develop an intervention using a two-step user-centered design process. First, parents and oncologists provided input on the design. Second, a parent panel and two oncology nurses refined draft materials. In a feasibility study, we used questionnaires to assess usefulness and acceptability. Medication error rates were assessed via monthly telephone interviews with parents. We successfully partnered with parents, clinicians, and IT experts to develop Home Medication Support (HoMeS), a family-centered Web-based intervention. HoMeS includes a medication calendar with decision support, a communication tool, adverse effect information, a metric conversion chart, and other information. The 15 families in the feasibility study gave HoMeS high ratings for acceptability and usefulness. Half recorded information on the calendar to indicate to other caregivers that doses were given; 34% brought it to the clinic to communicate with their clinician about home medication use. There was no change in the rate of medication errors in this feasibility study. We created and tested a stakeholder-designed, Web-based intervention to support home chemotherapy use, which parents rated highly. This tool may prevent serious medication errors in a larger study. Copyright © 2014 by American Society of Clinical Oncology.
Adverse Drug Events and Medication Errors in African Hospitals: A Systematic Review.
Mekonnen, Alemayehu B; Alhawassi, Tariq M; McLachlan, Andrew J; Brien, Jo-Anne E
2018-03-01
Medication errors and adverse drug events are universal problems contributing to patient harm but the magnitude of these problems in Africa remains unclear. The objective of this study was to systematically investigate the literature on the extent of medication errors and adverse drug events, and the factors contributing to medication errors in African hospitals. We searched PubMed, MEDLINE, EMBASE, Web of Science and Global Health databases from inception to 31 August, 2017 and hand searched the reference lists of included studies. Original research studies of any design published in English that investigated adverse drug events and/or medication errors in any patient population in the hospital setting in Africa were included. Descriptive statistics including median and interquartile range were presented. Fifty-one studies were included; of these, 33 focused on medication errors, 15 on adverse drug events, and three studies focused on medication errors and adverse drug events. These studies were conducted in nine (of the 54) African countries. In any patient population, the median (interquartile range) percentage of patients reported to have experienced any suspected adverse drug event at hospital admission was 8.4% (4.5-20.1%), while adverse drug events causing admission were reported in 2.8% (0.7-6.4%) of patients but it was reported that a median of 43.5% (20.0-47.0%) of the adverse drug events were deemed preventable. Similarly, the median mortality rate attributed to adverse drug events was reported to be 0.1% (interquartile range 0.0-0.3%). The most commonly reported types of medication errors were prescribing errors, occurring in a median of 57.4% (interquartile range 22.8-72.8%) of all prescriptions and a median of 15.5% (interquartile range 7.5-50.6%) of the prescriptions evaluated had dosing problems. Major contributing factors for medication errors reported in these studies were individual practitioner factors (e.g. fatigue and inadequate knowledge/training) and environmental factors, such as workplace distraction and high workload. Medication errors in the African healthcare setting are relatively common, and the impact of adverse drug events is substantial but many are preventable. This review supports the design and implementation of preventative strategies targeting the most likely contributing factors.
Al-lela, Omer Qutaiba B; Bahari, Mohd Baidi; Al-abbassi, Mustafa G; Salih, Muhannad R M; Basher, Amena Y
2012-06-06
The immunization status of children is improved by interventions that increase community demand for compulsory and non-compulsory vaccines, one of the most important interventions related to immunization providers. The aim of this study is to evaluate the activities of immunization providers in terms of activities time and cost, to calculate the immunization doses cost, and to determine the immunization dose errors cost. Time-motion and cost analysis study design was used. Five public health clinics in Mosul-Iraq participated in the study. Fifty (50) vaccine doses were required to estimate activities time and cost. Micro-costing method was used; time and cost data were collected for each immunization-related activity performed by the clinic staff. A stopwatch was used to measure the duration of activity interactions between the parents and clinic staff. The immunization service cost was calculated by multiplying the average salary/min by activity time per minute. 528 immunization cards of Iraqi children were scanned to determine the number and the cost of immunization doses errors (extraimmunization doses and invalid doses). The average time for child registration was 6.7 min per each immunization dose, and the physician spent more than 10 min per dose. Nurses needed more than 5 min to complete child vaccination. The total cost of immunization activities was 1.67 US$ per each immunization dose. Measles vaccine (fifth dose) has a lower price (0.42 US$) than all other immunization doses. The cost of a total of 288 invalid doses was 744.55 US$ and the cost of a total of 195 extra immunization doses was 503.85 US$. The time spent on physicians' activities was longer than that spent on registrars' and nurses' activities. Physician total cost was higher than registrar cost and nurse cost. The total immunization cost will increase by about 13.3% owing to dose errors. Copyright © 2012 Elsevier Ltd. All rights reserved.
Uy, Raymonde Charles Y.; Kury, Fabricio P.; Fontelo, Paul A.
2015-01-01
The standard of safe medication practice requires strict observance of the five rights of medication administration: the right patient, drug, time, dose, and route. Despite adherence to these guidelines, medication errors remain a public health concern that has generated health policies and hospital processes that leverage automation and computerization to reduce these errors. Bar code, RFID, biometrics and pharmacy automation technologies have been demonstrated in literature to decrease the incidence of medication errors by minimizing human factors involved in the process. Despite evidence suggesting the effectivity of these technologies, adoption rates and trends vary across hospital systems. The objective of study is to examine the state and adoption trends of automatic identification and data capture (AIDC) methods and pharmacy automation technologies in U.S. hospitals. A retrospective descriptive analysis of survey data from the HIMSS Analytics® Database was done, demonstrating an optimistic growth in the adoption of these patient safety solutions. PMID:26958264
DOE Office of Scientific and Technical Information (OSTI.GOV)
Passarge, M; Fix, M K; Manser, P
Purpose: To create and test an accurate EPID-frame-based VMAT QA metric to detect gross dose errors in real-time and to provide information about the source of error. Methods: A Swiss cheese model was created for an EPID-based real-time QA process. The system compares a treatmentplan- based reference set of EPID images with images acquired over each 2° gantry angle interval. The metric utilizes a sequence of independent consecutively executed error detection Methods: a masking technique that verifies infield radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment to quantify rotation, scaling andmore » translation; standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each test were determined. For algorithm testing, twelve different types of errors were selected to modify the original plan. Corresponding predictions for each test case were generated, which included measurement-based noise. Each test case was run multiple times (with different noise per run) to assess the ability to detect introduced errors. Results: Averaged over five test runs, 99.1% of all plan variations that resulted in patient dose errors were detected within 2° and 100% within 4° (∼1% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 91.5% were detected by the system within 2°. Based on the type of method that detected the error, determination of error sources was achieved. Conclusion: An EPID-based during-treatment error detection system for VMAT deliveries was successfully designed and tested. The system utilizes a sequence of methods to identify and prevent gross treatment delivery errors. The system was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of errors in real-time and indicate the error source. J. V. Siebers receives funding support from Varian Medical Systems.« less
Detecting medication errors in the New Zealand pharmacovigilance database: a retrospective analysis.
Kunac, Desireé L; Tatley, Michael V
2011-01-01
Despite the traditional focus being adverse drug reactions (ADRs), pharmacovigilance centres have recently been identified as a potentially rich and important source of medication error data. To identify medication errors in the New Zealand Pharmacovigilance database (Centre for Adverse Reactions Monitoring [CARM]), and to describe the frequency and characteristics of these events. A retrospective analysis of the CARM pharmacovigilance database operated by the New Zealand Pharmacovigilance Centre was undertaken for the year 1 January-31 December 2007. All reports, excluding those relating to vaccines, clinical trials and pharmaceutical company reports, underwent a preventability assessment using predetermined criteria. Those events deemed preventable were subsequently classified to identify the degree of patient harm, type of error, stage of medication use process where the error occurred and origin of the error. A total of 1412 reports met the inclusion criteria and were reviewed, of which 4.3% (61/1412) were deemed preventable. Not all errors resulted in patient harm: 29.5% (18/61) were 'no harm' errors but 65.5% (40/61) of errors were deemed to have been associated with some degree of patient harm (preventable adverse drug events [ADEs]). For 5.0% (3/61) of events, the degree of patient harm was unable to be determined as the patient outcome was unknown. The majority of preventable ADEs (62.5% [25/40]) occurred in adults aged 65 years and older. The medication classes most involved in preventable ADEs were antibacterials for systemic use and anti-inflammatory agents, with gastrointestinal and respiratory system disorders the most common adverse events reported. For both preventable ADEs and 'no harm' events, most errors were incorrect dose and drug therapy monitoring problems consisting of failures in detection of significant drug interactions, past allergies or lack of necessary clinical monitoring. Preventable events were mostly related to the prescribing and administration stages of the medication use process, with the majority of errors 82.0% (50/61) deemed to have originated in the community setting. The CARM pharmacovigilance database includes medication errors, many of which were found to originate in the community setting and reported as ADRs. Error-prone situations were able to be identified, providing greater opportunity to improve patient safety. However, to enhance detection of medication errors by pharmacovigilance centres, reports should be prospectively reviewed for preventability and the reporting form revised to facilitate capture of important information that will provide meaningful insight into the nature of the underlying systems defects that caused the error.
Meesters, Kevin; Mauel, Reiner; Dhont, Evelyn; Walle, Johan Vande; De Bruyne, Pauline
2018-02-23
Fluoroquinolones (FQ) are increasingly prescribed for children, despite being labeled for only a limited number of labeled pediatric indications. In this multicenter retrospective drug utilization study, we analyzed indications for systemic FQ prescriptions in hospitalized children and the appropriateness of the prescribed dose. Using data obtained from electronic medical files, the study included all children who received a systemic FQ prescription in two Belgian university children's hospitals between 2010 and 2013. Two authors reviewed prescribed daily doses. Univariate and multivariate logistic regression models were used to analyze risk factors for inadequately dosing. Results262 FQ prescriptions for individual patients were included for analysis. 16.8% of these prescriptions were for labeled indications, and 35.1% were guided by bacteriological findings. Prescribed daily dose was considered to be inappropriate in 79 prescriptions (30.2%). Other FQ than ciprofloxacin accounted for 9 prescriptions (3.4%), of which 8 were correctly dosed. Underdosing represented 45 (56.9%) dosing errors. Infants and preschool children were at particular risk for dosing errors, with associated adjusted OR of 0.263 (0.097-0.701) and 0.254 (0.106-0.588) respectively. FQ were often prescribed off-label and not guided by bacteriological findings in our study population. Dosing errors were common, particularly in infants and preschool children. FQ prescriptions for children should be improved by specific pediatric antimicrobial stewardship teams. Furthermore, pharmacokinetic studies should optimise dosing recommendations for children.
Meyer-Massetti, Carla; Krummenacher, Evelyne; Hedinger-Grogg, Barbara; Luterbacher, Stephan; Hersberger, Kurt E
2016-09-01
Background: While drug-related problems are among the most frequent adverse events in health care, little is known about their type and prevalence in home care in the current literature. The use of a Critical Incident Reporting System (CIRS), known as an economic and efficient tool to record medication errors for subsequent analysis, is widely implemented in inpatient care, but less established in ambulatory care. Recommendations on a possible format are scarce. A manual CIRS was developed based on the literature and subsequently piloted and implemented in a Swiss home care organization. Aim: The aim of this work was to implement a critical incident reporting system specifically for medication safety in home care. Results: The final CIRS form was well accepted among staff. Requiring limited resources, it allowed preliminary identification and trending of medication errors in home care. The most frequent error reports addressed medication preparation at the patients’ home, encompassing the following errors: omission (30 %), wrong dose (17.5 %) and wrong time (15 %). The most frequent underlying causes were related to working conditions (37.9 %), lacking attention (68.2 %), time pressure (22.7 %) and interruptions by patients (9.1 %). Conclusions: A manual CIRS allowed efficient data collection and subsequent analysis of medication errors in order to plan future interventions for improvement of medication safety. The development of an electronic CIRS would allow a reduction of the expenditure of time regarding data collection and analysis. In addition, it would favour the development of a national CIRS network among home care institutions.
McCoy, Allison B; McCoy, Allison Beck; Peterson, Josh F; Gadd, Cynthia S; Gadd, Cindy; Danciu, Ioana; Waitman, Lemuel R
2008-11-06
Clinical decision support systems can decrease common errors related to inappropriate or excessive dosing for nephrotoxic or renally cleared drugs. We developed a comprehensive medication safety intervention with varying levels of workflow intrusiveness within computerized provider order entry to continuously monitor for and alert providers about early-onset acute kidney injury. Initial provider response to the interventions shows potential success in improving medication safety and suggests future enhancements to increase effectiveness.
De Oliveira, Gildasio S; Rahmani, Rod; Fitzgerald, Paul C; Chang, Ray; McCarthy, Robert J
2013-04-01
Poor supervision of physician trainees can be detrimental not only to resident education but also to patient care and safety. Inadequate supervision has been associated with more frequent deaths of patients under the care of junior residents. We hypothesized that residents reporting more medical errors would also report lower quality of supervision scores than the ones with lower reported medical errors. The primary objective of this study was to evaluate the association between the frequency of medical errors reported by residents and their perceived quality of faculty supervision. A cross-sectional nationwide survey was sent to 1000 residents randomly selected from anesthesiology training departments across the United States. Residents from 122 residency programs were invited to participate, the median (interquartile range) per institution was 7 (4-11). Participants were asked to complete a survey assessing demography, perceived quality of faculty supervision, and perceived causes of inadequate perceived supervision. Responses to the statements "I perform procedures for which I am not properly trained," "I make mistakes that have negative consequences for the patient," and "I have made a medication error (drug or incorrect dose) in the last year" were used to assess error rates. Average supervision scores were determined using the De Oliveira Filho et al. scale and compared among the frequency of self-reported error categories using the Kruskal-Wallis test. Six hundred four residents responded to the survey (60.4%). Forty-five (7.5%) of the respondents reported performing procedures for which they were not properly trained, 24 (4%) reported having made mistakes with negative consequences to patients, and 16 (3%) reported medication errors in the last year having occurred multiple times or often. Supervision scores were inversely correlated with the frequency of reported errors for all 3 questions evaluating errors. At a cutoff value of 3, supervision scores demonstrated an overall accuracy (area under the curve) (99% confidence interval) of 0.81 (0.73-0.86), 0.89 (0.77-0.95), and 0.93 (0.77-0.98) for predicting a response of multiple times or often to the question of performing procedures for which they were not properly trained, reported mistakes with negative consequences to patients, and reported medication errors in the last year, respectively. Anesthesiology trainees who reported a greater incidence of medical errors with negative consequences to patients and drug errors also reported lower scores for supervision by faculty. Our findings suggest that further studies of the association between supervision and patient safety are warranted. (Anesth Analg 2013;116:892-7).
MacKay, Mark; Anderson, Collin; Boehme, Sabrina; Cash, Jared; Zobell, Jeffery
2016-04-01
The Institute for Safe Medication Practices has stated that parenteral nutrition (PN) is considered a high-risk medication and has the potential of causing harm. Three organizations--American Society for Parenteral and Enteral Nutrition (A.S.P.E.N.), American Society of Health-System Pharmacists, and National Advisory Group--have published guidelines for ordering, transcribing, compounding and administering PN. These national organizations have published data on compliance to the guidelines and the risk of errors. The purpose of this article is to compare total compliance with ordering, transcription, compounding, administration, and error rate with a large pediatric institution. A computerized prescriber order entry (CPOE) program was developed that incorporates dosing with soft and hard stop recommendations and simultaneously eliminating the need for paper transcription. A CPOE team prioritized and identified issues, then developed solutions and integrated innovative CPOE and automated compounding device (ACD) technologies and practice changes to minimize opportunities for medication errors in PN prescription, transcription, preparation, and administration. Thirty developmental processes were identified and integrated in the CPOE program, resulting in practices that were compliant with A.S.P.E.N. safety consensus recommendations. Data from 7 years of development and implementation were analyzed and compared with published literature comparing error, harm rates, and cost reductions to determine if our process showed lower error rates compared with national outcomes. The CPOE program developed was in total compliance with the A.S.P.E.N. guidelines for PN. The frequency of PN medication errors at our hospital over the 7 years was 230 errors/84,503 PN prescriptions, or 0.27% compared with national data that determined that 74 of 4730 (1.6%) of prescriptions over 1.5 years were associated with a medication error. Errors were categorized by steps in the PN process: prescribing, transcription, preparation, and administration. There were no transcription errors, and most (95%) errors occurred during administration. We conclude that PN practices that conferred a meaningful cost reduction and a lower error rate (2.7/1000 PN) than reported in the literature (15.6/1000 PN) were ascribed to the development and implementation of practices that conform to national PN guidelines and recommendations. Electronic ordering and compounding programs eliminated all transcription and related opportunities for errors. © 2015 American Society for Parenteral and Enteral Nutrition.
Farfán Sedano, Francisco J; Terrón Cuadrado, Marta; Castellanos Clemente, Yolanda; Serrano Balazote, Pablo; Moner Cano, David; Robles Viejo, Montserrat
2011-01-01
The comparison of the patient's current medication list with the medication being ordered when admitted to Hospital, identifying omissions, duplications, dosing errors, and potential interactions, constitutes the core process of medicines reconciliation. Access to the medication the patient is taking at home could be unfeasible as this information is frequently stored in various locations and in diverse proprietary formats. The lack of interoperability between those information systems, namely the Primary Care and the Specialized Electronic Health Records (EHRs), facilitates medication errors and endangers patient safety. Thus, the development of a Patient Summary that includes clinical data from different electronic systems will allow doctors access to relevant information enabling a safer and more efficient assistance. Such a collection of data from heterogeneous and distributed systems has been achieved in this Project through the construction of a federated view based on the ISO/CEN EN13606 Standard for architecture and communication of EHRs.
Shehata, Zahraa Hassan Abdelrahman; Sabri, Nagwa Ali; Elmelegy, Ahmed Abdelsalam
2016-03-01
This study analyzes reports to the Egyptian medication error (ME) reporting system from June to December 2014. Fifty hospital pharmacists received training on ME reporting using the national reporting system. All received reports were reviewed and analyzed. The pieces of data analyzed were patient age, gender, clinical setting, stage, type, medication(s), outcome, cause(s), and recommendation(s). Over the course of 6 months, 12,000 valid reports were gathered and included in this analysis. The majority (66%) came from inpatient settings, while 23% came from intensive care units, and 11% came from outpatient departments. Prescribing errors were the most common type of MEs (54%), followed by monitoring (25%) and administration errors (16%). The most frequent error was incorrect dose (20%) followed by drug interactions, incorrect drug, and incorrect frequency. Most reports were potential (25%), prevented (11%), or harmless (51%) errors; only 13% of reported errors lead to patient harm. The top three medication classes involved in reported MEs were antibiotics, drugs acting on the central nervous system, and drugs acting on the cardiovascular system. Causes of MEs were mostly lack of knowledge, environmental factors, lack of drug information sources, and incomplete prescribing. Recommendations for addressing MEs were mainly staff training, local ME reporting, and improving work environment. There are common problems among different healthcare systems, so that sharing experiences on the national level is essential to enable learning from MEs. Internationally, there is a great need for standardizing ME terminology, to facilitate knowledge transfer. Underreporting, inaccurate reporting, and a lack of reporter diversity are some limitations of this study. Egypt now has a national database of MEs that allows researchers and decision makers to assess the problem, identify its root causes, and develop preventive strategies. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Reducing medication errors and increasing patient safety: case studies in clinical pharmacology.
Benjamin, David M
2003-07-01
Today, reducing medication errors and improving patient safety have become common topics of discussion for the president of the United States, federal and state legislators, the insurance industry, pharmaceutical companies, health care professionals, and patients. But this is not news to clinical pharmacologists. Improving the judicious use of medications and minimizing adverse drug reactions have always been key areas of research and study for those working in clinical pharmacology. However, added to the older terms of adverse drug reactions and rational therapeutics, the now politically correct expression of medication error has emerged. Focusing on the word error has drawn attention to "prevention" and what can be done to minimize mistakes and improve patient safety. Webster's New Collegiate Dictionary has several definitions of error, but the one that seems to be most appropriate in the context of medication errors is "an act that through ingnorance, deficiency, or accident departs from or fails to achieve what should be done." What should be done is generally known as "the five rights": the right drug, right dose, right route, right time, and right patient. One can make an error of omission (failure to act correctly) or an error of commission (acted incorrectly). This article now summarizes what is currently known about medication errors and translates the information into case studies illustrating common scenarios leading to medication errors. Each case is analyzed to provide insight into how the medication error could have been prevented. "System errors" are described, and the application of failure mode effect analysis (FMEA) is presented to determine the part of the "safety net" that failed. Examples of reengineering the system to make it more "error proof" are presented. An error can be prevented. However, the practice of medicine, pharmacy, and nursing in the hospital setting is very complicated, and so many steps occur from "pen to patient" that there is a lot to analyze. Implementing safer practices requires developing safer systems. Many errors occur as a result of poor oral or written communications. Enhanced communication skills and better interactions among members of the health care team and the patient are essential. The informed consent process should be used as a patient safety tool, and the patient should be warned about material and foreseeable serious side effects and be told what signs and symptoms should be immediately reported to the physician before the patient is forced to go to the emergency department for urgent or emergency care. Last, reducing medication errors is an ongoing process of quality improvement. Faculty systems must be redesigned, and seamless, computerized integrated medication delivery must be instituted by health care professionals adequately trained to use such technological advances. Sloppy handwritten prescriptions should be replaced by computerized physician order entry, a very effective technique for reducing prescribing/ordering errors, but another far less expensive yet effective change would involve writing all drug orders in plain English, rather than continuing to use the elitists' arcane Latin words and shorthand abbreviations that are subject to misinterpretation. After all, effective communication is best accomplished when it is clear and simple.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faught, J Tonigan; Johnson, J; Stingo, F
2015-06-15
Purpose: To assess the perception of TG-142 tolerance level dose delivery failures in IMRT and the application of FMEA process to this specific aspect of IMRT. Methods: An online survey was distributed to medical physicists worldwide that briefly described 11 different failure modes (FMs) covered by basic quality assurance in step- and-shoot IMRT at or near TG-142 tolerance criteria levels. For each FM, respondents estimated the worst case H&N patient percent dose error and FMEA scores for Occurrence, Detectability, and Severity. Demographic data was also collected. Results: 181 individual and three group responses were submitted. 84% were from North America.more » Most (76%) individual respondents performed at least 80% clinical work and 92% were nationally certified. Respondent medical physics experience ranged from 2.5–45 years (average 18 years). 52% of individual respondents were at least somewhat familiar with FMEA, while 17% were not familiar. Several IMRT techniques, treatment planning systems and linear accelerator manufacturers were represented. All FMs received widely varying scores ranging from 1–10 for occurrence, at least 1–9 for detectability, and at least 1–7 for severity. Ranking FMs by RPN scores also resulted in large variability, with each FM being ranked both most risky (1st ) and least risky (11th) by different respondents. On average MLC modeling had the highest RPN scores. Individual estimated percent dose errors and severity scores positively correlated (p<0.10) for each FM as expected. No universal correlations were found between the demographic information collected and scoring, percent dose errors, or ranking. Conclusion: FMs investigated overall were evaluated as low to medium risk, with average RPNs less than 110. The ranking of 11 FMs was not agreed upon by the community. Large variability in FMEA scoring may be caused by individual interpretation and/or experience, thus reflecting the subjective nature of the FMEA tool.« less
A prospective audit of a nurse independent prescribing within critical care.
Carberry, Martin; Connelly, Sarah; Murphy, Jennifer
2013-05-01
To determine the prescribing activity of different staff groups within intensive care unit (ICU) and combined high dependency unit (HDU), namely trainee and consultant medical staff and advanced nurse practitioners in critical care (ANPCC); to determine the number and type of prescription errors; to compare error rates between prescribing groups and to raise awareness of prescribing activity within critical care. The introduction of government legislation has led to the development of non-medical prescribing roles in acute care. This has facilitated an opportunity for the ANPCC working in critical care to develop a prescribing role. The audit was performed over 7 days (Monday-Sunday), on rolling days over a 7-week period in September and October 2011 in three ICUs. All drug entries made on the ICU prescription by the three groups, trainee medical staff, ANPCCs and consultant anaesthetists, were audited once for errors. Data were collected by reviewing all drug entries for errors namely, patient data, drug dose, concentration, rate and frequency, legibility and prescriber signature. A paper data collection tool was used initially; data was later entered onto a Microsoft Access data base. A total of 1418 drug entries were audited from 77 patient prescription Cardexes. Error rates were reported as, 40 errors in 1418 prescriptions (2·8%): ANPCC errors, n = 2 in 388 prescriptions (0·6%); trainee medical staff errors, n = 33 in 984 (3·4%); consultant errors, n = 5 in 73 (6·8%). The error rates were significantly different for different prescribing groups (p < 0·01). This audit shows that prescribing error rates were low (2·8%). Having the lowest error rate, the nurse practitioners are at least as effective as other prescribing groups within this audit, in terms of errors only, in prescribing diligence. National data is required in order to benchmark independent nurse prescribing practice in critical care. These findings could be used to inform research and role development within the critical care. © 2012 The Authors. Nursing in Critical Care © 2012 British Association of Critical Care Nurses.
Mannitol dosing error during interfacility transfer for intracranial emergencies.
Elliott, Cameron A; MacKenzie, Mark; O'Kelly, Cian J
2015-11-01
Mannitol is commonly used to treat elevated intracranial pressure (ICP). The authors analyzed mannitol dosing errors at peripheral hospitals prior to or during transport to tertiary care facilities for intracranial emergencies. They also investigated the appropriateness of mannitol use based on the 2007 Brain Trauma Foundation guidelines for severe traumatic brain injury. The authors conducted a retrospective review of the Shock Trauma Air Rescue Society (STARS) electronic patient database of helicopter medical evacuations in Alberta, Canada, between 2004 and 2012, limited to patients receiving mannitol before transfer. They extracted data on mannitol administration and patient characteristics, including diagnosis, mechanism, Glasgow Coma Scale score, weight, age, and pupil status. A total of 120 patients with an intracranial emergency received a mannitol infusion initiated at a peripheral hospital (median Glasgow Coma Scale score 6; range 3-13). Overall, there was a 22% dosing error rate, which comprised an underdosing rate (<0.25 g/kg) of 8.3% (10 of 120 patients), an overdosing rate (>1.5 g/kg) of 7.5% (9 of 120), and a nonbolus administration rate (>1 hour) of 6.7% (8 of 120). Overall, 72% of patients had a clear indication to receive mannitol as defined by meeting at least one of the following criteria based on Brain Trauma Foundation guidelines: neurological deterioration (11%), severe traumatic brain injury (69%), or pupillary abnormality (25%). Mannitol administration at peripheral hospitals is prone to dosing error. Strategies such as a pretransport checklist may mitigate this risk.
Wallace, Darlene; Woolley, Torres; Martin, David; Rasalam, Roy; Bellei, Maria
2016-01-01
Medication errors are the second most frequently reported hospital incident in Australia and are a global concern. A "Medication Calculation and Administration" workshop followed by a "hurdle" assessment (compulsory task mandating a minimum level of performance as a condition of passing the course) was introduced into Year 2 of the James Cook University medical curriculum to decrease dosage calculation and administration errors among graduates. This study evaluates the effectiveness of this educational activity as a long-term strategy to teach medical students' essential skills in calculating and administering medications. This longitudinal study used a pre- and post-test design to determine whether medical students retained their calculation and administration skills over a period of 4 years. The ability to apply basic mathematical skills to medication dose calculation, principles of safe administration (Part 1), and ability to access reference materials to check indications, contraindications, and writing the medication order with correct abbreviations (Part 2) were compared between Year 2 and 6 assessments. Scores for Parts 1, 2 and total scores were nearly identical from Year 2 to Year 6 (P = 0.663, 0.408, and 0.472, respectively), indicating minimal loss of knowledge by students in this period. Most Year 6 students (86%) were able to recall at least 5 of the "6 Rights of Medication Administration" while 84% reported accessing reference material and 91% reported checking their medical calculations. The "Medication Calculation and Administration" workshop with a combined formative and summative assessment - a "hurdle" - promotes long-term retention of essential clinical skills for medical students. These skills and an awareness of the problem are strategies to assist medical graduates in preventing future medication-related adverse events.
Niedrig, David; Krattinger, Regina; Jödicke, Annika; Gött, Carmen; Bucklar, Guido; Russmann, Stefan
2016-10-01
Overdosing of the oral antidiabetic metformin in impaired renal function is an important contributory cause to life-threatening lactic acidosis. The presented project aimed to quantify and prevent this avoidable medication error in clinical practice. We developed and implemented an algorithm into a hospital's clinical information system that prospectively identifies metformin prescriptions if the estimated glomerular filtration rate is below 60 mL/min. Resulting real-time electronic alerts are sent to clinical pharmacologists and pharmacists, who validate cases in electronic medical records and contact prescribing physicians with recommendations if necessary. The screening algorithm has been used in routine clinical practice for 3 years and generated 2145 automated alerts (about 2 per day). Validated expert recommendations regarding metformin therapy, i.e., dose reduction or stop, were issued for 381 patients (about 3 per week). Follow-up was available for 257 cases, and prescribers' compliance with recommendations was 79%. Furthermore, during 3 years, we identified eight local cases of lactic acidosis associated with metformin therapy in renal impairment that could not be prevented, e.g., because metformin overdosing had occurred before hospitalization. Automated sensitive screening followed by specific expert evaluation and personal recommendations can prevent metformin overdosing in renal impairment with high efficiency and efficacy. Repeated cases of metformin-associated lactic acidosis in renal impairment underline the clinical relevance of this medication error. Our locally developed and customized alert system is a successful proof of concept for a proactive clinical drug safety program that is now expanded to other clinically and economically relevant medication errors. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
National trends in safety performance of electronic health record systems in children's hospitals.
Chaparro, Juan D; Classen, David C; Danforth, Melissa; Stockwell, David C; Longhurst, Christopher A
2017-03-01
To evaluate the safety of computerized physician order entry (CPOE) and associated clinical decision support (CDS) systems in electronic health record (EHR) systems at pediatric inpatient facilities in the US using the Leapfrog Group's pediatric CPOE evaluation tool. The Leapfrog pediatric CPOE evaluation tool, a previously validated tool to assess the ability of a CPOE system to identify orders that could potentially lead to patient harm, was used to evaluate 41 pediatric hospitals over a 2-year period. Evaluation of the last available test for each institution was performed, assessing performance overall as well as by decision support category (eg, drug-drug, dosing limits). Longitudinal analysis of test performance was also carried out to assess the impact of testing and the overall trend of CPOE performance in pediatric hospitals. Pediatric CPOE systems were able to identify 62% of potential medication errors in the test scenarios, but ranged widely from 23-91% in the institutions tested. The highest scoring categories included drug-allergy interactions, dosing limits (both daily and cumulative), and inappropriate routes of administration. We found that hospitals with longer periods since their CPOE implementation did not have better scores upon initial testing, but after initial testing there was a consistent improvement in testing scores of 4 percentage points per year. Pediatric computerized physician order entry (CPOE) systems on average are able to intercept a majority of potential medication errors, but vary widely among implementations. Prospective and repeated testing using the Leapfrog Group's evaluation tool is associated with improved ability to intercept potential medication errors. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Paquin, Allison M; Zimmerman, Kristin M; Kostas, Tia R; Pelletier, Lindsey; Hwang, Angela; Simone, Mark; Skarf, Lara M; Rudolph, James L
2013-11-01
Complex medication regimens are error prone and challenging for patients, which may impact medication adherence and safety. No universal method to assess the complexity of medication regimens (CMRx) exists. The authors aim to review literature for CMRx measurements to establish consistencies and, secondarily, describe CMRx impact on healthcare outcomes. A search of EMBASE and PubMed for studies analyzing at least two medications and complexity components, among those self-managing medications, was conducted. Out of 1204 abstracts, 38 studies were included in the final sample. The majority (74%) of studies used one of five validated CMRx scales; their components and scoring were compared. Universal CMRx assessment is needed to identify and reduce complex regimens, and, thus, improve safety. The authors highlight commonalities among five scales to help build consensus. Common components (i.e., regimen factors) included dosing frequency, units per dose, and non-oral routes. Elements (e.g., twice daily) of these components (e.g., dosing frequency) and scoring varied. Patient-specific factors (e.g., dexterity, cognition) were not addressed, which is a shortcoming of current scales and a challenge for future scales. As CMRx has important outcomes, notably adherence and healthcare utilization, a standardized tool has potential for far-reaching clinical, research, and patient-safety impact.
[Failure mode and effects analysis on computerized drug prescriptions].
Paredes-Atenciano, J A; Roldán-Aviña, J P; González-García, Mercedes; Blanco-Sánchez, M C; Pinto-Melero, M A; Pérez-Ramírez, C; Calvo Rubio-Burgos, Miguel; Osuna-Navarro, F J; Jurado-Carmona, A M
2015-01-01
To identify and analyze errors in drug prescriptions of patients treated in a "high resolution" hospital by applying a Failure mode and effects analysis (FMEA).Material and methods A multidisciplinary group of medical specialties and nursing analyzed medical records where drug prescriptions were held in free text format. An FMEA was developed in which the risk priority index (RPI) was obtained from a cross-sectional observational study using an audit of the medical records, carried out in 2 phases: 1) Pre-intervention testing, and (2) evaluation of improvement actions after the first analysis. An audit sample size of 679 medical records from a total of 2,096 patients was calculated using stratified sampling and random selection of clinical events. Prescription errors decreased by 22.2% in the second phase. FMEA showed a greater RPI in "unspecified route of administration" and "dosage unspecified", with no significant decreases observed in the second phase, although it did detect, "incorrect dosing time", "contraindication due to drug allergy", "wrong patient" or "duplicate prescription", which resulted in the improvement of prescriptions. Drug prescription errors have been identified and analyzed by FMEA methodology, improving the clinical safety of these prescriptions. This tool allows updates of electronic prescribing to be monitored. To avoid such errors would require the mandatory completion of all sections of a prescription. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
Blandford, Ann; Furniss, Dominic; Lyons, Imogen; Chumbley, Gill; Iacovides, Ioanna; Wei, Li; Cox, Anna; Mayer, Astrid; Schnock, Kumiko; Bates, David Westfall; Dykes, Patricia C; Bell, Helen; Franklin, Bryony Dean
2016-03-03
Intravenous medication is essential for many hospital inpatients. However, providing intravenous therapy is complex and errors are common. 'Smart pumps' incorporating dose error reduction software have been widely advocated to reduce error. However, little is known about their effect on patient safety, how they are used or their likely impact. This study will explore the landscape of intravenous medication infusion practices and errors in English hospitals and how smart pumps may relate to the prevalence of medication administration errors. This is a mixed-methods study involving an observational quantitative point prevalence study to determine the frequency and types of errors that occur in the infusion of intravenous medication, and qualitative interviews with hospital staff to better understand infusion practices and the contexts in which errors occur. The study will involve 5 clinical areas (critical care, general medicine, general surgery, paediatrics and oncology), across 14 purposively sampled acute hospitals and 2 paediatric hospitals to cover a range of intravenous infusion practices. Data collectors will compare each infusion running at the time of data collection against the patient's medication orders to identify any discrepancies. The potential clinical importance of errors will be assessed. Quantitative data will be analysed descriptively; interviews will be analysed using thematic analysis. Ethical approval has been obtained from an NHS Research Ethics Committee (14/SC/0290); local approvals will be sought from each participating organisation. Findings will be published in peer-reviewed journals and presented at conferences for academic and health professional audiences. Results will also be fed back to participating organisations to inform local policy, training and procurement. Aggregated findings will inform the debate on costs and benefits of the NHS investing in smart pump technology, and what other changes may need to be made to ensure effectiveness of such an investment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Dose distribution and mapping with 3D imaging presentation in intraoral and panoramic examinations
NASA Astrophysics Data System (ADS)
Chen, Hsiu-Ling; Huang, Yung-Hui; Wu, Tung-Hsin; Wang, Shih-Yuan; Lee, Jason J. S.
2011-10-01
In current medical imaging applications, high quality images not only provide more diagnostic value for anatomic delineation but also offer functional information for treatment direction. However, this approach would potentially subscribe higher radiation dose in dental radiographies, which has been putatively associated with low-birth-weight during pregnancy, which affects the hypothalamus-pituitary-thyroid axis or thereby directly affects the reproductive organs. The aim of this study was to apply the high resolution 3-D image mapping technique to evaluate radiation doses from the following aspects: (1) verifying operating parameters of dental X-ray units, (2) measuring the leakage radiations and (3) mapping dose with 3-D radiographic imaging to evaluate dose distribution in head and neck regions. From the study results, we found that (1) leakage radiation from X-ray units was about 21.31±15.24 mR/h (<100 mR/h), (2) error of actual tube voltage for 60 kVp setting was from 0.2% to 6.5%, with an average of 2.5% (<7%) and (3) the error of exposure time for a 0.5-1.5 s setting was within 0.7-8.5%, with an average of 7.3% (<10%) error as well. Our 3-D dose mapping demonstrated that dose values were relatively lower in soft tissues and higher in bone surfaces compared with other investigations. Multiple causes could contribute to these variations, including irradiation geometry, image equipment and type of technique applied, etc. From the results, we also observed that larger accumulated doses were presented in certain critical organs, such as salivary gland, thyroid gland and bone marrow. Potential biological affects associated with these findings warrant further investigation.
Predicted blood glucose from insulin administration based on values from miscoded glucose meters.
Raine, Charles H; Pardo, Scott; Parkes, Joan Lee
2008-07-01
The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205-210, 2007). It attempts to relate potential insulin dose errors to possible adverse blood glucose outcomes when glucose meters are miscoded. Five sets of glucose meters were used. Two sets of meters were autocoded and therefore could not be miscoded, and three sets required manual coding. Two of each set of manually coded meters were deliberately miscoded, and one from each set was properly coded. Subjects (n = 116) had finger stick blood glucose obtained at fasting, as well as at 1 and 2 hours after a fixed meal (Boost((R)); Novartis Medical Nutrition U.S., Basel, Switzerland). Deviations of meter blood glucose results from the reference method (YSI) were used to predict insulin dose errors and resultant blood glucose outcomes based on these deviations. Using insulin sensitivity data, it was determined that, given an actual blood glucose of 150-400 mg/dl, an error greater than +40 mg/dl would be required to calculate an insulin dose sufficient to produce a blood glucose of less than 70 mg/dl. Conversely, an error less than or equal to -70 mg/dl would be required to derive an insulin dose insufficient to correct an elevated blood glucose to less than 180 mg/dl. For miscoded meters, the estimated probability to produce a blood glucose reduction to less than or equal to 70 mg/dl was 10.40%. The corresponding probabilities for autocoded and correctly coded manual meters were 2.52% (p < 0.0001) and 1.46% (p < 0.0001), respectively. Furthermore, the errors from miscoded meters were large enough to produce a calculated blood glucose outcome less than or equal to 50 mg/dl in 42 of 833 instances. Autocoded meters produced zero (0) outcomes less than or equal to 50 mg/dl out of 279 instances, and correctly coded manual meters produced 1 of 416. Improperly coded blood glucose meters present the potential for insulin dose errors and resultant clinically significant hypoglycemia or hyperglycemia. Patients should be instructed and periodically reinstructed in the proper use of blood glucose meters, particularly for meters that require coding.
An Analysis of 34,218 Pediatric Outpatient Controlled Substance Prescriptions.
George, Jessica A; Park, Paul S; Hunsberger, Joanne; Shay, Joanne E; Lehmann, Christoph U; White, Elizabeth D; Lee, Benjamin H; Yaster, Myron
2016-03-01
Prescription errors are among the most common types of iatrogenic errors. Because of a previously reported 82% error rate in handwritten discharge narcotic prescriptions, we developed a computerized, web-based, controlled substance prescription writer that includes weight-based dosing logic and alerts to reduce the error rate to (virtually) zero. Over the past 7 years, >34,000 prescriptions have been created by hospital providers using this platform. We sought to determine the ongoing efficacy of the program in prescription error reduction and the patterns with which providers prescribe controlled substances for children and young adults (ages 0-21 years) at hospital discharge. We examined a database of 34,218 controlled substance discharge prescriptions written by our institutional providers from January 1, 2007 to February 14, 2014, for demographic information, including age and weight, type of medication prescribed based on patient age, formulation of dispensed medication, and amount of drug to be dispensed at hospital discharge. In addition, we randomly regenerated 2% (700) of prescriptions based on stored data and analyzed them for errors using previously established error criteria. Weights that were manually entered into the prescription writer by the prescriber were compared with the patient's weight in the hospital's electronic medical record. Patients in the database averaged 9 ± 6.1 (range, 0-21) years of age and 36.7 ± 24.9 (1-195) kg. Regardless of age, the most commonly prescribed opioid was oxycodone (73%), which was prescribed as a single agent uncombined with acetaminophen. Codeine was prescribed to 7% of patients and always in a formulation containing acetaminophen. Liquid formulations were prescribed to 98% of children <6 years of age and to 16% of children >12 years of age (the remaining 84% received tablet formulations). Regardless of opioid prescribed, the amount of liquid dispensed averaged 106 ± 125 (range, 2-3240) mL, and the number of tablets dispensed averaged 51 ± 51 (range, 1-1080). Of the subset of 700 regenerated prescriptions, all were legible (drug, amount dispensed, dose, patient demographics, and provider name) and used best prescribing practice (e.g., no trailing zero after a decimal point, leading zero for doses <1). Twenty-five of the 700 (3.6%) had incorrectly entered weights compared with the most recent weight in the chart. Of these, 14 varied by 10% or less and only 2 varied by >15%. Of these, 1 resulted in underdosing (true weight 80 kg prescribed for a weight of 50 kg) and the other in overdosing (true weight 10 kg prescribed for a weight of 30 kg). A computerized prescription writer eliminated most but not all the errors common to handwritten prescriptions. Oxycodone has supplanted codeine as the most commonly prescribed oral opioid in current pediatric pain practice and, independent of formulation, is dispensed in large quantities. This study underscores the need for liquid opioid formulations in the pediatric population and, because of their abuse potential, the urgent need to determine how much of the prescribed medication is actually used by patients.
van Welie, Steven; Wijma, Linda; Beerden, Tim; van Doormaal, Jasperien; Taxis, Katja
2016-01-01
Objectives Residents of nursing homes often have difficulty swallowing (dysphagia), which complicates the administration of solid oral dosage formulations. Erroneously crushing medication is common, but few interventions have been tested to improve medication safety. Therefore, we evaluated the effect of warning symbols in combination with education on the frequency of erroneously crushing medication in nursing homes. Setting This was a prospective uncontrolled intervention study with a preintervention and postintervention measurement. The study was conducted on 18 wards (total of 200 beds) in 3 nursing homes in the North of the Netherlands. Participants We observed 36 nurses/nursing assistants (92% female; 92% nursing assistants) administering medication to 197 patients (62.9% female; mean age 81.6). Intervention The intervention consisted of a set of warning symbols printed on each patient's unit dose packaging indicating whether or not a medication could be crushed as well as education of ward staff (lectures, newsletter and poster). Primary outcome measure The relative risk (RR) of a crushing error occurring in the postintervention period compared to the preintervention period. A crushing error was defined as the crushing of a medication considered unsuitable to be crushed based on standard reference sources. Data were collected using direct (disguised) observation of nurses during drug administration. Results The crushing error rate decreased from 3.1% (21 wrongly crushed medicines out of 681 administrations) to 0.5% (3/636), RR=0.15 (95% CI 0.05 to 0.51). Likewise, there was a significant reduction using data from patients with swallowing difficulties only, 87.5% (21 errors/24 medications) to 30.0% (3/10) (RR 0.34, 95% CI 0.13 to 0.89). Medications which were erroneously crushed included enteric-coated formulations (eg, omeprazole), medication with regulated release systems (eg, Persantin; dipyridamol) and toxic substances (eg, finasteride). Conclusions Warning symbols combined with education reduced erroneous crushing of medication, a well-known and common problem in nursing homes. PMID:27496242
Online 3D EPID-based dose verification: Proof of concept.
Spreeuw, Hanno; Rozendaal, Roel; Olaciregui-Ruiz, Igor; González, Patrick; Mans, Anton; Mijnheer, Ben; van Herk, Marcel
2016-07-01
Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of this study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame, including dose verification, took 266 ± 11 ms on a dual octocore Intel Xeon E5-2630 CPU running at 2.40 GHz. The introduced delivery errors were detected after 5-10 s irradiation time. A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for two different kinds of gross delivery errors. Thus, online 3D dose verification has been technologically achieved.
Baker, J A; Lovell, K; Harris, N
2008-10-01
As required or pro re nata (PRN) psychotropic medicines are frequently used in acute mental health wards. PRN is known to contribute to polypharmacy and high doses of antipsychotic medication. Few studies have attempted to improve clinician's use of these potentially harmful drugs. The objectives of the study were to determine the impact and acceptability of a good practice manual on prescribing and administration practices of PRN psychotropic medication in acute mental health wards. The study used a pre-post exploratory design with two acute mental health wards in the NW of England. Over the total trial period of 10 weeks, 28 of 35 patients received 484 doses of PRN. Patients had a mean of 3.6 prescriptions of 14 different PRN medications in 34 different dose combinations prescribed. Medication errors beyond poor quality of prescribing occurred in 23 of the 35 patients (65.7%). Prescription quality improved following the introduction of the intervention but quality of nursing notes reduced. Acceptability of the manual to both nursing and medical staff was high. The introduction of the manual appeared to influence some of the practices associated with the prescribing and administration of PRN psychotropic medications. Further, larger, more robust studies are required in this area. In particular research is required to identify the reasons why professionals continue to rely so heavily on using PRN medication.
Simonsen, Bjoerg O; Daehlin, Gro K; Johansson, Inger; Farup, Per G
2014-10-24
Insufficient skills in drug dose calculations increase the risk for medication errors. Even experienced nurses may struggle with such calculations. Learning flexibility and cost considerations make e-learning interesting as an alternative to classroom teaching. This study compared the learning outcome and risk of error after a course in drug dose calculations for nurses with the two methods. In a randomised controlled open study, nurses from hospitals and primary healthcare were randomised to either e-learning or classroom teaching. Before and after a 2-day course, the nurses underwent a multiple choice test in drug dose calculations: 14 tasks with four alternative answers (score 0-14), and a statement regarding the certainty of each answer (score 0-3). High risk of error was being certain that incorrect answer was correct. The results are given as the mean (SD). 16 men and 167 women participated in the study, aged 42.0 (9.5) years with a working experience of 12.3 (9.5) years. The number of correct answers after e-learning was 11.6 (2.0) and after classroom teaching 11.9 (2.0) (p=0.18, NS); improvement were 0.5 (1.6) and 0.9 (2.2), respectively (p=0.07, NS). Classroom learning was significantly superior to e-learning among participants with a pretest score below 9. In support of e-learning was evaluation of specific value for the working situation. There was no difference in risk of error between groups after the course (p=0.77). The study showed no differences in learning outcome or risk of error between e-learning and classroom teaching in drug dose calculations. The overall learning outcome was small. Weak precourse knowledge was associated with better outcome after classroom teaching. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Simonsen, Bjoerg O; Daehlin, Gro K; Johansson, Inger; Farup, Per G
2014-01-01
Introduction Insufficient skills in drug dose calculations increase the risk for medication errors. Even experienced nurses may struggle with such calculations. Learning flexibility and cost considerations make e-learning interesting as an alternative to classroom teaching. This study compared the learning outcome and risk of error after a course in drug dose calculations for nurses with the two methods. Methods In a randomised controlled open study, nurses from hospitals and primary healthcare were randomised to either e-learning or classroom teaching. Before and after a 2-day course, the nurses underwent a multiple choice test in drug dose calculations: 14 tasks with four alternative answers (score 0–14), and a statement regarding the certainty of each answer (score 0–3). High risk of error was being certain that incorrect answer was correct. The results are given as the mean (SD). Results 16 men and 167 women participated in the study, aged 42.0 (9.5) years with a working experience of 12.3 (9.5) years. The number of correct answers after e-learning was 11.6 (2.0) and after classroom teaching 11.9 (2.0) (p=0.18, NS); improvement were 0.5 (1.6) and 0.9 (2.2), respectively (p=0.07, NS). Classroom learning was significantly superior to e-learning among participants with a pretest score below 9. In support of e-learning was evaluation of specific value for the working situation. There was no difference in risk of error between groups after the course (p=0.77). Conclusions The study showed no differences in learning outcome or risk of error between e-learning and classroom teaching in drug dose calculations. The overall learning outcome was small. Weak precourse knowledge was associated with better outcome after classroom teaching. PMID:25344483
Errors and omissions in hospital prescriptions: a survey of prescription writing in a hospital
Calligaris, Laura; Panzera, Angela; Arnoldo, Luca; Londero, Carla; Quattrin, Rosanna; Troncon, Maria G; Brusaferro, Silvio
2009-01-01
Background The frequency of drug prescription errors is high. Excluding errors in decision making, the remaining are mainly due to order ambiguity, non standard nomenclature and writing illegibility. The aim of this study is to analyse, as a part of a continuous quality improvement program, the quality of prescriptions writing for antibiotics, in an Italian University Hospital as a risk factor for prescription errors. Methods The point prevalence survey, carried out in May 26–30 2008, involved 41 inpatient Units. Every parenteral or oral antibiotic prescription was analysed for legibility (generic or brand drug name, dose, frequency of administration) and completeness (generic or brand name, dose, frequency of administration, route of administration, date of prescription and signature of the prescriber). Eight doctors (residents in Hygiene and Preventive Medicine) and two pharmacists performed the survey by reviewing the clinical records of medical, surgical or intensive care section inpatients. The antibiotics drug category was chosen because its use is widespread in the setting considered. Results Out of 756 inpatients included in the study, 408 antibiotic prescriptions were found in 298 patients (mean prescriptions per patient 1.4; SD ± 0.6). Overall 92.7% (38/41) of the Units had at least one patient with antibiotic prescription. Legibility was in compliance with 78.9% of generic or brand names, 69.4% of doses, 80.1% of frequency of administration, whereas completeness was fulfilled for 95.6% of generic or brand names, 76.7% of doses, 83.6% of frequency of administration, 87% of routes of administration, 43.9% of dates of prescription and 33.3% of physician's signature. Overall 23.9% of prescriptions were illegible and 29.9% of prescriptions were incomplete. Legibility and completeness are higher in unusual drugs prescriptions. Conclusion The Intensive Care Section performed best as far as quality of prescription writing was concerned when compared with the Medical and Surgical Sections. Nevertheless the overall illegibility and incompleteness (above 20%) are unacceptably high. Values need to be improved by enhancing the safety culture and in particular the awareness of the professionals on the consequences that a bad prescription writing can produce. PMID:19439066
Errors and omissions in hospital prescriptions: a survey of prescription writing in a hospital.
Calligaris, Laura; Panzera, Angela; Arnoldo, Luca; Londero, Carla; Quattrin, Rosanna; Troncon, Maria G; Brusaferro, Silvio
2009-05-13
The frequency of drug prescription errors is high. Excluding errors in decision making, the remaining are mainly due to order ambiguity, non standard nomenclature and writing illegibility. The aim of this study is to analyse, as a part of a continuous quality improvement program, the quality of prescriptions writing for antibiotics, in an Italian University Hospital as a risk factor for prescription errors. The point prevalence survey, carried out in May 26-30 2008, involved 41 inpatient Units. Every parenteral or oral antibiotic prescription was analysed for legibility (generic or brand drug name, dose, frequency of administration) and completeness (generic or brand name, dose, frequency of administration, route of administration, date of prescription and signature of the prescriber). Eight doctors (residents in Hygiene and Preventive Medicine) and two pharmacists performed the survey by reviewing the clinical records of medical, surgical or intensive care section inpatients. The antibiotics drug category was chosen because its use is widespread in the setting considered. Out of 756 inpatients included in the study, 408 antibiotic prescriptions were found in 298 patients (mean prescriptions per patient 1.4; SD +/- 0.6). Overall 92.7% (38/41) of the Units had at least one patient with antibiotic prescription. Legibility was in compliance with 78.9% of generic or brand names, 69.4% of doses, 80.1% of frequency of administration, whereas completeness was fulfilled for 95.6% of generic or brand names, 76.7% of doses, 83.6% of frequency of administration, 87% of routes of administration, 43.9% of dates of prescription and 33.3% of physician's signature. Overall 23.9% of prescriptions were illegible and 29.9% of prescriptions were incomplete. Legibility and completeness are higher in unusual drugs prescriptions. The Intensive Care Section performed best as far as quality of prescription writing was concerned when compared with the Medical and Surgical Sections.Nevertheless the overall illegibility and incompleteness (above 20%) are unacceptably high. Values need to be improved by enhancing the safety culture and in particular the awareness of the professionals on the consequences that a bad prescription writing can produce.
Shaw, Paul B; Donovan, Jennifer L; Tran, Maichi T; Lemon, Stephenie C; Burgwinkle, Pamela; Gore, Joel
2010-08-01
The objectives of this retrospective cohort study are to evaluate the accuracy of pharmacogenetic warfarin dosing algorithms in predicting therapeutic dose and to determine if this degree of accuracy warrants the routine use of genotyping to prospectively dose patients newly started on warfarin. Seventy-one patients of an outpatient anticoagulation clinic at an academic medical center who were age 18 years or older on a stable, therapeutic warfarin dose with international normalized ratio (INR) goal between 2.0 and 3.0, and cytochrome P450 isoenzyme 2C9 (CYP2C9) and vitamin K epoxide reductase complex subunit 1 (VKORC1) genotypes available between January 1, 2007 and September 30, 2008 were included. Six pharmacogenetic warfarin dosing algorithms were identified from the medical literature. Additionally, a 5 mg fixed dose approach was evaluated. Three algorithms, Zhu et al. (Clin Chem 53:1199-1205, 2007), Gage et al. (J Clin Ther 84:326-331, 2008), and International Warfarin Pharmacogenetic Consortium (IWPC) (N Engl J Med 360:753-764, 2009) were similar in the primary accuracy endpoints with mean absolute error (MAE) ranging from 1.7 to 1.8 mg/day and coefficient of determination R (2) from 0.61 to 0.66. However, the Zhu et al. algorithm severely over-predicted dose (defined as >or=2x or >or=2 mg/day more than actual dose) in twice as many (14 vs. 7%) patients as Gage et al. 2008 and IWPC 2009. In conclusion, the algorithms published by Gage et al. 2008 and the IWPC 2009 were the two most accurate pharmacogenetically based equations available in the medical literature in predicting therapeutic warfarin dose in our study population. However, the degree of accuracy demonstrated does not support the routine use of genotyping to prospectively dose all patients newly started on warfarin.
Son, Seok Hyun; Kang, Young Nam; Ryu, Mi-Ryeong
2012-01-01
The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapy Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p < 0.001), and this showed a statistically significant difference among the kinds of CT images: the effect of metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
A Secure ECC-based RFID Mutual Authentication Protocol to Enhance Patient Medication Safety.
Jin, Chunhua; Xu, Chunxiang; Zhang, Xiaojun; Li, Fagen
2016-01-01
Patient medication safety is an important issue in patient medication systems. In order to prevent medication errors, integrating Radio Frequency Identification (RFID) technology into automated patient medication systems is required in hospitals. Based on RFID technology, such systems can provide medical evidence for patients' prescriptions and medicine doses, etc. Due to the mutual authentication between the medication server and the tag, RFID authentication scheme is the best choice for automated patient medication systems. In this paper, we present a RFID mutual authentication scheme based on elliptic curve cryptography (ECC) to enhance patient medication safety. Our scheme can achieve security requirements and overcome various attacks existing in other schemes. In addition, our scheme has better performance in terms of computational cost and communication overhead. Therefore, the proposed scheme is well suitable for patient medication systems.
Fully Convolutional Architecture for Low-Dose CT Image Noise Reduction
NASA Astrophysics Data System (ADS)
Badretale, S.; Shaker, F.; Babyn, P.; Alirezaie, J.
2017-10-01
One of the critical topics in medical low-dose Computed Tomography (CT) imaging is how best to maintain image quality. As the quality of images decreases with lowering the X-ray radiation dose, improving image quality is extremely important and challenging. We have proposed a novel approach to denoise low-dose CT images. Our algorithm learns directly from an end-to-end mapping from the low-dose Computed Tomography images for denoising the normal-dose CT images. Our method is based on a deep convolutional neural network with rectified linear units. By learning various low-level to high-level features from a low-dose image the proposed algorithm is capable of creating a high-quality denoised image. We demonstrate the superiority of our technique by comparing the results with two other state-of-the-art methods in terms of the peak signal to noise ratio, root mean square error, and a structural similarity index.
Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siebers, Jeffrey V.; Keall, Paul J.; Wu Qiuwen
2005-10-01
Purpose: The purpose of this study is to determine dose delivery errors that could result from random and systematic setup errors for head-and-neck patients treated using the simultaneous integrated boost (SIB)-intensity-modulated radiation therapy (IMRT) technique. Methods and Materials: Twenty-four patients who participated in an intramural Phase I/II parotid-sparing IMRT dose-escalation protocol using the SIB treatment technique had their dose distributions reevaluated to assess the impact of random and systematic setup errors. The dosimetric effect of random setup error was simulated by convolving the two-dimensional fluence distribution of each beam with the random setup error probability density distribution. Random setup errorsmore » of {sigma} = 1, 3, and 5 mm were simulated. Systematic setup errors were simulated by randomly shifting the patient isocenter along each of the three Cartesian axes, with each shift selected from a normal distribution. Systematic setup error distributions with {sigma} = 1.5 and 3.0 mm along each axis were simulated. Combined systematic and random setup errors were simulated for {sigma} = {sigma} = 1.5 and 3.0 mm along each axis. For each dose calculation, the gross tumor volume (GTV) received by 98% of the volume (D{sub 98}), clinical target volume (CTV) D{sub 90}, nodes D{sub 90}, cord D{sub 2}, and parotid D{sub 50} and parotid mean dose were evaluated with respect to the plan used for treatment for the structure dose and for an effective planning target volume (PTV) with a 3-mm margin. Results: Simultaneous integrated boost-IMRT head-and-neck treatment plans were found to be less sensitive to random setup errors than to systematic setup errors. For random-only errors, errors exceeded 3% only when the random setup error {sigma} exceeded 3 mm. Simulated systematic setup errors with {sigma} = 1.5 mm resulted in approximately 10% of plan having more than a 3% dose error, whereas a {sigma} = 3.0 mm resulted in half of the plans having more than a 3% dose error and 28% with a 5% dose error. Combined random and systematic dose errors with {sigma} = {sigma} = 3.0 mm resulted in more than 50% of plans having at least a 3% dose error and 38% of the plans having at least a 5% dose error. Evaluation with respect to a 3-mm expanded PTV reduced the observed dose deviations greater than 5% for the {sigma} = {sigma} = 3.0 mm simulations to 5.4% of the plans simulated. Conclusions: Head-and-neck SIB-IMRT dosimetric accuracy would benefit from methods to reduce patient systematic setup errors. When GTV, CTV, or nodal volumes are used for dose evaluation, plans simulated including the effects of random and systematic errors deviate substantially from the nominal plan. The use of PTVs for dose evaluation in the nominal plan improves agreement with evaluated GTV, CTV, and nodal dose values under simulated setup errors. PTV concepts should be used for SIB-IMRT head-and-neck squamous cell carcinoma patients, although the size of the margins may be less than those used with three-dimensional conformal radiation therapy.« less
SU-E-T-186: Cloud-Based Quality Assurance Application for Linear Accelerator Commissioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, J
2015-06-15
Purpose: To identify anomalies and safety issues during data collection and modeling for treatment planning systems Methods: A cloud-based quality assurance system (AQUIRE - Automated QUalIty REassurance) has been developed to allow the uploading and analysis of beam data aquired during the treatment planning system commissioning process. In addition to comparing and aggregating measured data, tools have also been developed to extract dose from the treatment planning system for end-to-end testing. A gamma index is perfomed on the data to give a dose difference and distance-to-agreement for validation that a beam model is generating plans consistent with the beam datamore » collection. Results: Over 20 linear accelerators have been commissioning using this platform, and a variety of errors and potential saftey issues have been caught through the validation process. For example, the gamma index of 2% dose, 2mm DTA is quite sufficient to see curves not corrected for effective point of measurement. Also, data imported into the database is analyzed against an aggregate of similar linear accelerators to show data points that are outliers. The resulting curves in the database exhibit a very small standard deviation and imply that a preconfigured beam model based on aggregated linear accelerators will be sufficient in most cases. Conclusion: With the use of this new platform for beam data commissioning, errors in beam data collection and treatment planning system modeling are greatly reduced. With the reduction in errors during acquisition, the resulting beam models are quite similar, suggesting that a common beam model may be possible in the future. Development is ongoing to create routine quality assurance tools to compare back to the beam data acquired during commissioning. I am a medical physicist for Alzyen Medical Physics, and perform commissioning services.« less
[Impact of a software application to improve medication reconciliation at hospital discharge].
Corral Baena, S; Garabito Sánchez, M J; Ruíz Rómero, M V; Vergara Díaz, M A; Martín Chacón, E R; Fernández Moyano, A
2014-01-01
To assess the impact of a software application to improve the quality of information concerning current patient medications and changes on the discharge report after hospitalization. To analyze the incidence of errors and to classify them. Quasi-experimental pre / post study with non-equivalent control group study. Medical patients at hospital discharge. implementation of a software application. Percentage of reconciled patient medication on discharge, and percentage of patients with more than one unjustified discrepancy. A total of 349 patients were assessed; 199 (pre-intervention phase) and 150 (post-intervention phase). Before the implementation of the application in 157 patients (78.8%) medication reconciliation had been completed; finding reconciliation errors in 99 (63.0%). The most frequent type of error, 339 (78.5%), was a missing dose or administration frequency information. After implementation, all the patient prescriptions were reconciled when the software was used. The percentage of patients with unjustified discrepancies decreased from 63.0% to 11.8% with the use of the application (p<.001). The main type of discrepancy found on using the application was confusing prescription, due to the fact that the professionals were not used to using the new tool. The use of a software application has been shown to improve the quality of the information on patient treatment on the hospital discharge report, but it is still necessary to continue development as a strategy for improving medication reconciliation. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
Cortejoso, L; Dietz, RA; Hofmann, G; Gosch, M; Sattler, A
2016-01-01
Background Inappropriate pharmacotherapy among older adults remains a critical issue in our health care systems. Besides polypharmacy and multiple comorbidities, the age-related pharmacokinetic and pharmacodynamic changes may increase the risk of adverse drug reactions and medication errors. Objective The main target of this study was to describe the characteristics of pharmaceutical interventions in two geriatric wards (orthogeriatric ward and geriatric day unit) of a general teaching hospital and to evaluate the clinical significance of the detected medication errors. Materials and methods The study was conducted between August 2014 and October 2015 and was based on a triple approach that included validation of medical orders, medication reconciliation at patients’ admission, and a predischarge planning appointment with the patient. The validation of medical orders was based on analyzing the suitability of the drugs prescribed, the drug dose depending on the patient’s characteristics, the presence of contraindications and interactions between drugs, and the proposal of alternative drugs included in the hospital formulary. Results A total of 2,307 interventions associated to a medication error in 15,282 medical orders for 1,859 older patients were recorded. The greater part of the interventions carried out on the orthogeriatric ward at admission and at discharge were due to omission of a drug in the medical order (20.0%) and clinically significant interactions requiring monitoring (30.4%), respectively. The main factor triggering pharmacist’s recommendations on the geriatric day unit was clinically significant interactions (21.1%). With regard to the clinical severity of the detected errors, 68.1% were considered significant, 24.8% were of minor significance, and 7.2% were clinically serious. Conclusion Our findings show the importance of clinical pharmacist involvement in the optimization of pharmacotherapy in older adults, ensuring that they receive effective, safe, and efficient drug therapy. PMID:27713625
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hub, Martina; Thieke, Christian; Kessler, Marc L.
2012-04-15
Purpose: In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. However, uncertainties in the mapping of the images can translate into errors of the accumulated total dose, depending on the dose gradient. In this work, an approach to estimate the uncertainty of mapping between medical images is proposed that identifies areas bearing a significant risk of inaccurate dose accumulation. Methods: This method accounts formore » the geometric uncertainty of image registration and the heterogeneity of the dose distribution, which is to be mapped. Its performance is demonstrated in context of dose mapping based on b-spline registration. It is based on evaluation of the sensitivity of dose mapping to variations of the b-spline coefficients combined with evaluation of the sensitivity of the registration metric with respect to the variations of the coefficients. It was evaluated based on patient data that was deformed based on a breathing model, where the ground truth of the deformation, and hence the actual true dose mapping error, is known. Results: The proposed approach has the potential to distinguish areas of the image where dose mapping is likely to be accurate from other areas of the same image, where a larger uncertainty must be expected. Conclusions: An approach to identify areas where dose mapping is likely to be inaccurate was developed and implemented. This method was tested for dose mapping, but it may be applied in context of other mapping tasks as well.« less
Hub, Martina; Thieke, Christian; Kessler, Marc L.; Karger, Christian P.
2012-01-01
Purpose: In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. However, uncertainties in the mapping of the images can translate into errors of the accumulated total dose, depending on the dose gradient. In this work, an approach to estimate the uncertainty of mapping between medical images is proposed that identifies areas bearing a significant risk of inaccurate dose accumulation. Methods: This method accounts for the geometric uncertainty of image registration and the heterogeneity of the dose distribution, which is to be mapped. Its performance is demonstrated in context of dose mapping based on b-spline registration. It is based on evaluation of the sensitivity of dose mapping to variations of the b-spline coefficients combined with evaluation of the sensitivity of the registration metric with respect to the variations of the coefficients. It was evaluated based on patient data that was deformed based on a breathing model, where the ground truth of the deformation, and hence the actual true dose mapping error, is known. Results: The proposed approach has the potential to distinguish areas of the image where dose mapping is likely to be accurate from other areas of the same image, where a larger uncertainty must be expected. Conclusions: An approach to identify areas where dose mapping is likely to be inaccurate was developed and implemented. This method was tested for dose mapping, but it may be applied in context of other mapping tasks as well. PMID:22482640
Predicted Blood Glucose from Insulin Administration Based on Values from Miscoded Glucose Meters
Raine, Charles H.; Pardo, Scott; Parkes, Joan Lee
2008-01-01
Objectives The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205–210, 2007). It attempts to relate potential insulin dose errors to possible adverse blood glucose outcomes when glucose meters are miscoded. Methods Five sets of glucose meters were used. Two sets of meters were autocoded and therefore could not be miscoded, and three sets required manual coding. Two of each set of manually coded meters were deliberately miscoded, and one from each set was properly coded. Subjects (n = 116) had finger stick blood glucose obtained at fasting, as well as at 1 and 2 hours after a fixed meal (Boost®; Novartis Medical Nutrition U.S., Basel, Switzerland). Deviations of meter blood glucose results from the reference method (YSI) were used to predict insulin dose errors and resultant blood glucose outcomes based on these deviations. Results Using insulin sensitivity data, it was determined that, given an actual blood glucose of 150–400 mg/dl, an error greater than +40 mg/dl would be required to calculate an insulin dose sufficient to produce a blood glucose of less than 70 mg/dl. Conversely, an error less than or equal to -70 mg/dl would be required to derive an insulin dose insufficient to correct an elevated blood glucose to less than 180 mg/dl. For miscoded meters, the estimated probability to produce a blood glucose reduction to less than or equal to 70 mg/dl was 10.40%. The corresponding probabilities for autocoded and correctly coded manual meters were 2.52% (p < 0.0001) and 1.46% (p < 0.0001), respectively. Furthermore, the errors from miscoded meters were large enough to produce a calculated blood glucose outcome less than or equal to 50 mg/dl in 42 of 833 instances. Autocoded meters produced zero (0) outcomes less than or equal to 50 mg/dl out of 279 instances, and correctly coded manual meters produced 1 of 416. Conclusions Improperly coded blood glucose meters present the potential for insulin dose errors and resultant clinically significant hypoglycemia or hyperglycemia. Patients should be instructed and periodically reinstructed in the proper use of blood glucose meters, particularly for meters that require coding. PMID:19885229
Using failure mode and effects analysis to plan implementation of smart i.v. pump technology.
Wetterneck, Tosha B; Skibinski, Kathleen A; Roberts, Tanita L; Kleppin, Susan M; Schroeder, Mark E; Enloe, Myra; Rough, Steven S; Hundt, Ann Schoofs; Carayon, Pascale
2006-08-15
Failure mode and effects analysis (FMEA) was used to evaluate a smart i.v. pump as it was implemented into a redesigned medication-use process. A multidisciplinary team conducted a FMEA to guide the implementation of a smart i.v. pump that was designed to prevent pump programming errors. The smart i.v. pump was equipped with a dose-error reduction system that included a pre-defined drug library in which dosage limits were set for each medication. Monitoring for potential failures and errors occurred for three months postimplementation of FMEA. Specific measures were used to determine the success of the actions that were implemented as a result of the FMEA. The FMEA process at the hospital identified key failure modes in the medication process with the use of the old and new pumps, and actions were taken to avoid errors and adverse events. I.V. pump software and hardware design changes were also recommended. Thirteen of the 18 failure modes reported in practice after pump implementation had been identified by the team. A beneficial outcome of FMEA was the development of a multidisciplinary team that provided the infrastructure for safe technology implementation and effective event investigation after implementation. With the continual updating of i.v. pump software and hardware after implementation, FMEA can be an important starting place for safe technology choice and implementation and can produce site experts to follow technology and process changes over time. FMEA was useful in identifying potential problems in the medication-use process with the implementation of new smart i.v. pumps. Monitoring for system failures and errors after implementation remains necessary.
Online 3D EPID-based dose verification: Proof of concept
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spreeuw, Hanno; Rozendaal, Roel, E-mail: r.rozenda
Purpose: Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of thismore » study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. Methods: The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. Results: The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame, including dose verification, took 266 ± 11 ms on a dual octocore Intel Xeon E5-2630 CPU running at 2.40 GHz. The introduced delivery errors were detected after 5–10 s irradiation time. Conclusions: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for two different kinds of gross delivery errors. Thus, online 3D dose verification has been technologically achieved.« less
Predicting Pulmonary O2 Toxicity: A New Look at the Unit Pulmonary Toxicity Dose
1985-05-01
beatl loeged# aNy ahepes in Vo was considered error. The assumptieo was shoe eapeova to a 10 below the "safe’! I02 should have produced se daeromeat...Naval Medical Research Institute SethesdolMO 20814-505b NMRI 86-52 December 1986 PREDICTING4 PULMONARY 0 2 TOXICITY: j k,, NEW LOOK AT THE UNIT...distribution is unlimited °Q0- C(-" Naval Medical Research LLj and Development Command ,, J Bethesda, Maryland 20814-5044 -4 • Department of the Navy Naval
van Welie, Steven; Wijma, Linda; Beerden, Tim; van Doormaal, Jasperien; Taxis, Katja
2016-08-05
Residents of nursing homes often have difficulty swallowing (dysphagia), which complicates the administration of solid oral dosage formulations. Erroneously crushing medication is common, but few interventions have been tested to improve medication safety. Therefore, we evaluated the effect of warning symbols in combination with education on the frequency of erroneously crushing medication in nursing homes. This was a prospective uncontrolled intervention study with a preintervention and postintervention measurement. The study was conducted on 18 wards (total of 200 beds) in 3 nursing homes in the North of the Netherlands. We observed 36 nurses/nursing assistants (92% female; 92% nursing assistants) administering medication to 197 patients (62.9% female; mean age 81.6). The intervention consisted of a set of warning symbols printed on each patient's unit dose packaging indicating whether or not a medication could be crushed as well as education of ward staff (lectures, newsletter and poster). The relative risk (RR) of a crushing error occurring in the postintervention period compared to the preintervention period. A crushing error was defined as the crushing of a medication considered unsuitable to be crushed based on standard reference sources. Data were collected using direct (disguised) observation of nurses during drug administration. The crushing error rate decreased from 3.1% (21 wrongly crushed medicines out of 681 administrations) to 0.5% (3/636), RR=0.15 (95% CI 0.05 to 0.51). Likewise, there was a significant reduction using data from patients with swallowing difficulties only, 87.5% (21 errors/24 medications) to 30.0% (3/10) (RR 0.34, 95% CI 0.13 to 0.89). Medications which were erroneously crushed included enteric-coated formulations (eg, omeprazole), medication with regulated release systems (eg, Persantin; dipyridamol) and toxic substances (eg, finasteride). Warning symbols combined with education reduced erroneous crushing of medication, a well-known and common problem in nursing homes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Evaluation of students' knowledge about paediatric dosage calculations.
Özyazıcıoğlu, Nurcan; Aydın, Ayla İrem; Sürenler, Semra; Çinar, Hava Gökdere; Yılmaz, Dilek; Arkan, Burcu; Tunç, Gülseren Çıtak
2018-01-01
Medication errors are common and may jeopardize the patient safety. As paediatric dosages are calculated based on the child's age and weight, risk of error in dosage calculations is increasing. In paediatric patients, overdose drug prescribed regardless of the child's weight, age and clinical picture may lead to excessive toxicity and mortalities while low doses may delay the treatment. This study was carried out to evaluate the knowledge of nursing students about paediatric dosage calculations. This research, which is of retrospective type, covers a population consisting of all the 3rd grade students at the bachelor's degree in May, 2015 (148 students). Drug dose calculation questions in exam papers including 3 open ended questions on dosage calculation problems, addressing 5 variables were distributed to the students and their responses were evaluated by the researchers. In the evaluation of the data, figures and percentage distribution were calculated and Spearman correlation analysis was applied. Exam question on the dosage calculation based on child's age, which is the most common method in paediatrics, and which ensures right dosages and drug dilution was answered correctly by 87.1% of the students while 9.5% answered it wrong and 3.4% left it blank. 69.6% of the students was successful in finding the safe dose range, and 79.1% in finding the right ratio/proportion. 65.5% of the answers with regard to Ml/dzy calculation were correct. Moreover, student's four operation skills were assessed and 68.2% of the students were determined to have found the correct answer. When the relation among the questions on medication was examined, a significant relation (correlation) was determined between them. It is seen that in dosage calculations, the students failed mostly in calculating ml/dzy (decimal). This result means that as dosage calculations are based on decimal values, calculations may be ten times erroneous when the decimal point is placed wrongly. Moreover, it is also seen that students lack maths knowledge in respect of four operations and calculating safe dose range. Relations among the medications suggest that a student wrongly calculating a dosage may also make other errors. Additional courses, exercises or utilisation of different teaching techniques may be suggested to eliminate the deficiencies in terms of basic maths knowledge, problem solving skills and correct dosage calculation of the students. Copyright © 2017 Elsevier Ltd. All rights reserved.
Phillips, Katherine W; Ansell, Jack
2008-01-01
Oral anticoagulation therapy with warfarin is the mainstay of prevention and treatment of thromboembolic disease. However, it remains one of the leading causes of harmful medication errors and medication-related adverse events. The beneficial outcomes of oral anticoagulation therapy are directly dependent upon the quality of dose and anticoagulation management, but the literature is not robust with regards to what constitutes such management. This review focuses on, and attempts to define, the parameters of high-quality anticoagulation management and identifies the appropriate outcome measures constituting high-quality management. Elements discussed include the most fundamental measure, time in therapeutic range, along with other parameters including therapy initiation, time to therapeutic range, dosing management when patients are not in therapeutic range, perioperative dosing management, patient education, and other important outcome measures. Healthcare providers who manage oral anticoagulation therapy should utilize these parameters as a measure of their performance in an effort to achieve high-quality anticoagulation management.
Evaluating the technique of using inhalation device in COPD and bronchial asthma patients.
Arora, Piyush; Kumar, Lokender; Vohra, Vikram; Sarin, Rohit; Jaiswal, Anand; Puri, M M; Rathee, Deepti; Chakraborty, Pitambar
2014-07-01
In asthma management, poor handling of inhalation devices and wrong inhalation technique are associated with decreased medication delivery and poor disease control. The key to overcome the drawbacks in inhalation technique is to make patients familiar with issues related to correct use and performance of these medical devices. The objective of this study was to evaluate and analyse technique of use of the inhalation device used by patients of COPD and Bronchial Asthma. A total of 300 cases of BA or COPD patients using different types of inhalation devices were included in this observational study. Data were captured using a proforma and were analysed using SPSS version 15.0. Out of total 300 enrolled patients, 247 (82.3%) made at least one error. Maximum errors observed in subjects using MDI (94.3%), followed by DPI (82.3%), MDI with Spacer (78%) while Nebulizer users (70%) made least number of errors (p = 0.005). Illiterate patients showed 95.2% error while post-graduate and professionals showed 33.3%. This difference was statistically significant (p < 0.001). Self-educated patients committed 100% error, while those trained by a doctor made 56.3% error. Majority of patients using inhalation devices made errors while using the device. Proper education to patients on correct usage may not only improve control of the symptoms of the disease but might also allow dose reduction in long term. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Renu; Jursinic, Paul A.
2013-07-15
Purpose: To show the feasibility of clinical implementation of OSLDs for high dose-rate (HDR) in vivo dosimetry for gynecological and breast patients. To discuss how the OSLDs were characterized for an Ir-192 source, taking into account low gamma energy and high dose gradients. To describe differences caused by the dose calculation formalism of treatment planning systems.Methods: OSLD irradiations were made using the GammaMedplus iX Ir-192 HDR, Varian Medical Systems, Milpitas, CA. BrachyVision versions 8.9 and 10.0, Varian Medical Systems, Milpitas, CA, were used for calculations. Version 8.9 used the TG-43 algorithm and version 10.0 used the Acuros algorithm. The OSLDsmore » (InLight Nanodots) were characterized for Ir-192. Various phantoms were created to assess calculated and measured doses and the angular dependence and self-absorption of the Nanodots. Following successful phantom measurements, patient measurements for gynecological patients and breast cancer patients were made and compared to calculated doses.Results: The OSLD sensitivity to Ir-192 compared to 6 MV is between 1.10 and 1.25, is unique to each detector, and changes with accumulated dose. The measured doses were compared to those predicted by the treatment planning system and found to be in agreement for the gynecological patients to within measurement uncertainty. The range of differences between the measured and Acuros calculated doses was -10%-14%. For the breast patients, there was a discrepancy of -4.4% to +6.5% between the measured and calculated doses at the skin surface when the Acuros algorithm was used. These differences were within experimental uncertainty due to (random) error in the location of the detector with respect to the treatment catheter.Conclusions: OSLDs can be successfully used for HDR in vivo dosimetry. However, for the measurements to be meaningful one must account for the angular dependence, volume-averaging, and the greater sensitivity to Ir-192 gamma rays than to 6 MV x-rays if 6 MV x-rays were used for OSLD calibration. The limitations of the treatment planning algorithm must be understood, especially for surface dose measurements. Use of in vivo dosimetry for HDR brachytherapy treatments is feasible and has the potential to detect and prevent gross errors. In vivo HDR brachytherapy should be included as part of the QA for a HDR brachytherapy program.« less
An RFID solution for enhancing inpatient medication safety with real-time verifiable grouping-proof.
Chen, Yu-Yi; Tsai, Meng-Lin
2014-01-01
The occurrence of a medication error can threaten patient safety. The medication administration process is complex and cumbersome, and nursing staffs are prone to error when they are tired. Proper Information Technology (IT) can assist the nurse in correct medication administration. We review a recent proposal regarding a leading-edge solution to enhance inpatient medication safety by using RFID technology. The proof mechanism is the kernel concept in their design and worth studying to develop a well-designed grouping-proof scheme. Other RFID grouping-proof protocols could be similarly applied in administering physician orders. We improve on the weaknesses of previous works and develop a reading-order independent RFID grouping-proof scheme in this paper. In our scheme, tags are queried and verified under the direct control of the authorized reader without connecting to the back-end database server. Immediate verification in our design makes this application more portable and efficient and critical security issues have been analyzed by the threat model. Our scheme is suitable for the safe drug administration scenario and the drug package scenario in a hospital environment to enhance inpatient medication safety. It automatically checks for correct drug unit-dose and appropriate inpatient treatments. Copyright © 2013. Published by Elsevier Ireland Ltd.
[Assessment of two applications of medication self-management in older patients. Qualitative study].
Carrillo, I; Guilabert, M; Pérez-Jover, V; Mira, J J
2015-01-01
The aging population and the growing use of technology are two realities of modern society. Developing tools to support medication self-management to polymedicated elderly may contribute to increase their safety. To know how patients polymedicated and older than 64 years manage dose their medication and assessment the utility of two medication self-management applications, specifically analyzing management systems, medication errors and positive and improvable aspects of each of the tools presented. Seven focal groups with 59 patients from associations and health departments were conducted. In such meetings, they received the applications and they were encouraged to use it. Then, a several group questions were asked them about their health status, how they managed their medication and their assessment about the applications. Most participants reported to use memory strategies to take correctly their medication. They assessed positively the applications although some of them showed resistance to incorporate it in their daily routine. The simple interface and ease of use were the characteristics of the applications most appreciated by patients. Is possible to foster among elderly patients the use of technological tools to support the proper administration of medications with purpose is to decrease errors and increase safety. When designing health applications is necessary to take into account the preferences of those who are targeted. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawai, D; Takahashi, R; Kamima, T
Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used as the secondary check. AAA dose calculation engine has contributed to lung SBRT. We conducted a multi-institutional study to assess variation of prescription dose for lung SBRT when using AAA in reference to using Acuros XB and Clarkson algorithm. Methods: Six institutes in Japan participated in this study. All SBRT treatments were planed using AAA in Eclipse and Adaptive Convolve (AC) in Pinnacle3. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU,more » Triangle Product, Ishikawa, Japan), which implemented a Clarkson-based dose calculation algorithm using CT image dataset. A retrospective analysis for lung SBRT plans (73 patients) was performed to compute the confidence limit (CL, Average±2SD) in dose between the AAA and the SMU. In one of the institutes, a additional analysis was conducted to evaluate the variations between the AAA and the Acuros XB (AXB). Results: The CL for SMU shows larger systematic and random errors of 8.7±9.9 % for AAA than the errors of 5.7±4.2 % for AC. The variations of AAA correlated with the mean CT values in the voxels of PTV (a correlation coefficient : −0.7) . The comparison of AXB vs. AAA shows smaller systematic and random errors of −0.7±1.7%. The correlation between dose variations for AXB and the mean CT values in PTV was weak (0.4). However, there were several plans with more than 2% deviation of AAPM TG114 (Maximum: −3.3 %). Conclusion: In comparison for AC, prescription dose calculated by AAA may be more variable in lung SBRT patient. Even AXB comparison shows unexpected variation. Care should be taken for the use of AAA in lung SBRT. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, J; Followill, D; Howell, R
2015-06-15
Purpose: To investigate two strategies for reducing dose calculation errors near metal implants: use of CT metal artifact reduction methods and implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) method. Methods: Radiochromic film was used to measure the dose upstream and downstream of titanium and Cerrobend implants. To assess the dosimetric impact of metal artifact reduction methods, dose calculations were performed using baseline, uncorrected images and metal artifact reduction Methods: Philips O-MAR, GE’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI imaging with metal artifact reduction software applied (MARs).To assess the impact of metal kernels, titaniummore » and silver kernels were implemented into a commercial collapsed cone C/S algorithm. Results: The CT artifact reduction methods were more successful for titanium than Cerrobend. Interestingly, for beams traversing the metal implant, we found that errors in the dimensions of the metal in the CT images were more important for dose calculation accuracy than reduction of imaging artifacts. The MARs algorithm caused a distortion in the shape of the titanium implant that substantially worsened the calculation accuracy. In comparison to water kernel dose calculations, metal kernels resulted in better modeling of the increased backscatter dose at the upstream interface but decreased accuracy directly downstream of the metal. We also found that the success of metal kernels was dependent on dose grid size, with smaller calculation voxels giving better accuracy. Conclusion: Our study yielded mixed results, with neither the metal artifact reduction methods nor the metal kernels being globally effective at improving dose calculation accuracy. However, some successes were observed. The MARs algorithm decreased errors downstream of Cerrobend by a factor of two, and metal kernels resulted in more accurate backscatter dose upstream of metals. Thus, these two strategies do have the potential to improve accuracy for patients with metal implants in certain scenarios. This work was supported by Public Health Service grants CA 180803 and CA 10953 awarded by the National Cancer Institute, United States of Health and Human Services, and in part by Mobius Medical Systems.« less
A method to estimate the effect of deformable image registration uncertainties on daily dose mapping
Murphy, Martin J.; Salguero, Francisco J.; Siebers, Jeffrey V.; Staub, David; Vaman, Constantin
2012-01-01
Purpose: To develop a statistical sampling procedure for spatially-correlated uncertainties in deformable image registration and then use it to demonstrate their effect on daily dose mapping. Methods: Sequential daily CT studies are acquired to map anatomical variations prior to fractionated external beam radiotherapy. The CTs are deformably registered to the planning CT to obtain displacement vector fields (DVFs). The DVFs are used to accumulate the dose delivered each day onto the planning CT. Each DVF has spatially-correlated uncertainties associated with it. Principal components analysis (PCA) is applied to measured DVF error maps to produce decorrelated principal component modes of the errors. The modes are sampled independently and reconstructed to produce synthetic registration error maps. The synthetic error maps are convolved with dose mapped via deformable registration to model the resulting uncertainty in the dose mapping. The results are compared to the dose mapping uncertainty that would result from uncorrelated DVF errors that vary randomly from voxel to voxel. Results: The error sampling method is shown to produce synthetic DVF error maps that are statistically indistinguishable from the observed error maps. Spatially-correlated DVF uncertainties modeled by our procedure produce patterns of dose mapping error that are different from that due to randomly distributed uncertainties. Conclusions: Deformable image registration uncertainties have complex spatial distributions. The authors have developed and tested a method to decorrelate the spatial uncertainties and make statistical samples of highly correlated error maps. The sample error maps can be used to investigate the effect of DVF uncertainties on daily dose mapping via deformable image registration. An initial demonstration of this methodology shows that dose mapping uncertainties can be sensitive to spatial patterns in the DVF uncertainties. PMID:22320766
Fujibuchi, Toshioh; Murazaki, Hiroo; Kuramoto, Taku; Umedzu, Yoshiyuki; Ishigaki, Yung
2015-08-01
Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray. The energy, dose rate, and pulse fluoroscopy dependence were evaluated as the basic characteristics of this system for diagnostic X-ray using a fully digital fluoroscopy system. The error of 1 cm dose equivalent rate was less than 15% from 35.1 keV to 43.2 keV with energy correction using metal filter. It was possible to accurately measure the dose rate dependence of this system, which was highly linear until 100 μSv/h. This system showed a constant response to the pulse fluoroscopy. This system will become useful wireless dosimeter for the individual exposure management by improving the high dose rate and the energy characteristics.
Mino-León, Dolores; Reyes-Morales, Hortensia; Jasso, Luis; Douvoba, Svetlana Vladislavovna
2012-06-01
Inappropriate prescription is a relevant problem in primary health care settings in Mexico, with potentially harmful consequences for patients. To evaluate the effectiveness of incorporating a pharmacist into primary care health team to reduce prescription errors for patients with diabetes and/or hypertension. One Family Medicine Clinic from the Mexican Institute of Social Security in Mexico City. A "pharmacotherapy intervention" provided by pharmacists through a quasi experimental (before-after) design was carried out. Physicians who allowed access to their diabetes and/or hypertensive patients' medical records and prescriptions were included in the study. Prescription errors were classified as "filling", "clinical" or "both". Descriptive analysis, identification of potential drug-drug interactions (pD-DI), and comparison of the proportion of patients with prescriptions with errors detected "before" and "after" intervention were performed. Decrease in the proportion of patients who received prescriptions with errors after the intervention. Pharmacists detected at least one type of error in 79 out of 160 patients. Errors were "clinical", "both" and "filling" in 47, 21 and 11 of these patient's prescriptions respectively. Predominant errors were, in the subgroup of patient's prescriptions with "clinical" errors, pD-DI; in the subgroup of "both" errors, lack of information on dosing interval and pD-DI; and in the "filling" subgroup, lack of information on dosing interval. The pD-DI caused 50 % of the errors detected, from which 19 % were of major severity. The impact of the correction of errors post-intervention was observed in 19 % of patients who had erroneous prescriptions before the intervention of the pharmacist (49.3-30.3 %, p < 0.05). The impact of the intervention was relevant from a clinical point of view for the public health services in Mexico. The implementation of early warning systems of the most widely prescribed drugs is an alternative for reducing prescription errors and consequently the risks they may cause.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tortorelli, J.P.
1995-08-01
A workshop was held at the Idaho National Engineering Laboratory, August 16--18, 1994 on the topic of risk assessment on medical devices that use radioactive isotopes. Its purpose was to review past efforts to develop a risk assessment methodology to evaluate these devices, and to develop a program plan and a scoping document for future methodology development. This report contains a summary of that workshop. Participants included experts in the fields of radiation oncology, medical physics, risk assessment, human-error analysis, and human factors. Staff from the US Nuclear Regulatory Commission (NRC) associated with the regulation of medical uses of radioactivemore » materials and with research into risk-assessment methods participated in the workshop. The workshop participants concurred in NRC`s intended use of risk assessment as an important technology in the development of regulations for the medical use of radioactive material and encouraged the NRC to proceed rapidly with a pilot study. Specific recommendations are included in the executive summary and the body of this report. An appendix contains the 8 papers presented at the conference: NRC proposed policy statement on the use of probabilistic risk assessment methods in nuclear regulatory activities; NRC proposed agency-wide implementation plan for probabilistic risk assessment; Risk evaluation of high dose rate remote afterloading brachytherapy at a large research/teaching institution; The pros and cons of using human reliability analysis techniques to analyze misadministration events; Review of medical misadministration event summaries and comparison of human error modeling; Preliminary examples of the development of error influences and effects diagrams to analyze medical misadministration events; Brachytherapy risk assessment program plan; and Principles of brachytherapy quality assurance.« less
Identification of priorities for medication safety in neonatal intensive care.
Kunac, Desireé L; Reith, David M
2005-01-01
Although neonates are reported to be at greater risk of medication error than infants and older children, little is known about the causes and characteristics of error in this patient group. Failure mode and effects analysis (FMEA) is a technique used in industry to evaluate system safety and identify potential hazards in advance. The aim of this study was to identify and prioritize potential failures in the neonatal intensive care unit (NICU) medication use process through application of FMEA. Using the FMEA framework and a systems-based approach, an eight-member multidisciplinary panel worked as a team to create a flow diagram of the neonatal unit medication use process. Then by brainstorming, the panel identified all potential failures, their causes and their effects at each step in the process. Each panel member independently rated failures based on occurrence, severity and likelihood of detection to allow calculation of a risk priority score (RPS). The panel identified 72 failures, with 193 associated causes and effects. Vulnerabilities were found to be distributed across the entire process, but multiple failures and associated causes were possible when prescribing the medication and when preparing the drug for administration. The top ranking issue was a perceived lack of awareness of medication safety issues (RPS score 273), due to a lack of medication safety training. The next highest ranking issues were found to occur at the administration stage. Common potential failures related to errors in the dose, timing of administration, infusion pump settings and route of administration. Perceived causes were multiple, but were largely associated with unsafe systems for medication preparation and storage in the unit, variable staff skill level and lack of computerised technology. Interventions to decrease medication-related adverse events in the NICU should aim to increase staff awareness of medication safety issues and focus on medication administration processes.
Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Louwe, Robert J. W., E-mail: rob.louwe@ccdbh.org.nz; Satherley, Thomas; Day, Rebecca A.
Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed softwaremore » was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.« less
Evaluating a medical error taxonomy.
Brixey, Juliana; Johnson, Todd R; Zhang, Jiajie
2002-01-01
Healthcare has been slow in using human factors principles to reduce medical errors. The Center for Devices and Radiological Health (CDRH) recognizes that a lack of attention to human factors during product development may lead to errors that have the potential for patient injury, or even death. In response to the need for reducing medication errors, the National Coordinating Council for Medication Errors Reporting and Prevention (NCC MERP) released the NCC MERP taxonomy that provides a standard language for reporting medication errors. This project maps the NCC MERP taxonomy of medication error to MedWatch medical errors involving infusion pumps. Of particular interest are human factors associated with medical device errors. The NCC MERP taxonomy of medication errors is limited in mapping information from MEDWATCH because of the focus on the medical device and the format of reporting.
Detection and correction of prescription errors by an emergency department pharmacy service.
Stasiak, Philip; Afilalo, Marc; Castelino, Tanya; Xue, Xiaoqing; Colacone, Antoinette; Soucy, Nathalie; Dankoff, Jerrald
2014-05-01
Emergency departments (EDs) are recognized as a high-risk setting for prescription errors. Pharmacist involvement may be important in reviewing prescriptions to identify and correct errors. The objectives of this study were to describe the frequency and type of prescription errors detected by pharmacists in EDs, determine the proportion of errors that could be corrected, and identify factors associated with prescription errors. This prospective observational study was conducted in a tertiary care teaching ED on 25 consecutive weekdays. Pharmacists reviewed all documented prescriptions and flagged and corrected errors for patients in the ED. We collected information on patient demographics, details on prescription errors, and the pharmacists' recommendations. A total of 3,136 ED prescriptions were reviewed. The proportion of prescriptions in which a pharmacist identified an error was 3.2% (99 of 3,136; 95% confidence interval [CI] 2.5-3.8). The types of identified errors were wrong dose (28 of 99, 28.3%), incomplete prescription (27 of 99, 27.3%), wrong frequency (15 of 99, 15.2%), wrong drug (11 of 99, 11.1%), wrong route (1 of 99, 1.0%), and other (17 of 99, 17.2%). The pharmacy service intervened and corrected 78 (78 of 99, 78.8%) errors. Factors associated with prescription errors were patient age over 65 (odds ratio [OR] 2.34; 95% CI 1.32-4.13), prescriptions with more than one medication (OR 5.03; 95% CI 2.54-9.96), and those written by emergency medicine residents compared to attending emergency physicians (OR 2.21, 95% CI 1.18-4.14). Pharmacists in a tertiary ED are able to correct the majority of prescriptions in which they find errors. Errors are more likely to be identified in prescriptions written for older patients, those containing multiple medication orders, and those prescribed by emergency residents.
Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sumida, Iori, E-mail: sumida@radonc.med.osaka-u.ac.jp; Yamaguchi, Hajime; Kizaki, Hisao
2015-07-15
Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV,more » spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katsuta, Y; Tohoku University Graduate School of Medicine, Sendal, Miyagi; Kadoya, N
Purpose: In this study, we developed a system to calculate three dimensional (3D) dose that reflects dosimetric error caused by leaf miscalibration for head and neck and prostate volumetric modulated arc therapy (VMAT) without additional treatment planning system calculation on real time. Methods: An original system called clarkson dose calculation based dosimetric error calculation to calculate dosimetric error caused by leaf miscalibration was developed by MATLAB (Math Works, Natick, MA). Our program, first, calculates point doses at isocenter for baseline and modified VMAT plan, which generated by inducing MLC errors that enlarged aperture size of 1.0 mm with clarkson dosemore » calculation. Second, error incuced 3D dose was generated with transforming TPS baseline 3D dose using calculated point doses. Results: Mean computing time was less than 5 seconds. For seven head and neck and prostate plans, between our method and TPS calculated error incuced 3D dose, the 3D gamma passing rates (0.5%/2 mm, global) are 97.6±0.6% and 98.0±0.4%. The dose percentage change with dose volume histogram parameter of mean dose on target volume were 0.1±0.5% and 0.4±0.3%, and with generalized equivalent uniform dose on target volume were −0.2±0.5% and 0.2±0.3%. Conclusion: The erroneous 3D dose calculated by our method is useful to check dosimetric error caused by leaf miscalibration before pre treatment patient QA dosimetry checks.« less
Underestimation of Low-Dose Radiation in Treatment Planning of Intensity-Modulated Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jang, Si Young; Liu, H. Helen; Mohan, Radhe
2008-08-01
Purpose: To investigate potential dose calculation errors in the low-dose regions and identify causes of such errors for intensity-modulated radiotherapy (IMRT). Methods and Materials: The IMRT treatment plans of 23 patients with lung cancer and mesothelioma were reviewed. Of these patients, 15 had severe pulmonary complications after radiotherapy. Two commercial treatment-planning systems (TPSs) and a Monte Carlo system were used to calculate and compare dose distributions and dose-volume parameters of the target volumes and critical structures. The effect of tissue heterogeneity, multileaf collimator (MLC) modeling, beam modeling, and other factors that could contribute to the differences in IMRT dose calculationsmore » were analyzed. Results: In the commercial TPS-generated IMRT plans, dose calculation errors primarily occurred in the low-dose regions of IMRT plans (<50% of the radiation dose prescribed for the tumor). Although errors in the dose-volume histograms of the normal lung were small (<5%) above 10 Gy, underestimation of dose <10 Gy was found to be up to 25% in patients with mesothelioma or large target volumes. These errors were found to be caused by inadequate modeling of MLC transmission and leaf scatter in commercial TPSs. The degree of low-dose errors depends on the target volumes and the degree of intensity modulation. Conclusions: Secondary radiation from MLCs contributes a significant portion of low dose in IMRT plans. Dose underestimation could occur in conventional IMRT dose calculations if such low-dose radiation is not properly accounted for.« less
Komase, Yuko; Asako, Akimoto; Kobayashi, Akihiro; Sharma, Raj
2014-01-01
In patients receiving inhaled medication, dissatisfaction with and difficulty in using the inhaler can affect treatment adherence. The incidence of handling errors is typically higher in the elderly than in younger people. The aim of the study was to assess inhaler preference for and handling errors with the ELLIPTA® dry powder inhaler (DPI), (GSK), compared with the established BREEZHALER™, a single-dose capsule DPI (Novartis), in inhalation device-naïve Japanese volunteers aged ≥40 years. In this open-label, nondrug interventional, crossover DPI preference study comparing the ELLIPTA DPI and BREEZHALER, 150 subjects were randomized to handle the ELLIPTA or BREEZHALER DPIs until the point of inhalation, without receiving verbal or demonstrative instruction (first attempt). Subjects then crossed over to the other inhaler. Preference was assessed using a self-completed questionnaire. Inhaler handling was assessed by a trained assessor using a checklist. Subjects did not inhale any medication in the study, so efficacy and safety were not measured. The ELLIPTA DPI was preferred to the BREEZHALER by 89% of subjects (odds ratio [OR] 70.14, 95% confidence interval [CI] 33.69-146.01; P-value not applicable for this inhaler) for ease of use, by 63% of subjects (OR 2.98, CI 1.87-4.77; P<0.0001) for ease of determining the number of doses remaining in the inhaler, by 91% for number of steps required, and by 93% for time needed for handling the inhaler. The BREEZHALER was preferred to the ELLIPTA DPI for comfort of the mouthpiece by 64% of subjects (OR 3.16, CI 1.97-5.06; P<0.0001). The incidence of handling errors (first attempt) was 11% with ELLIPTA and 68% with BREEZHALER; differences in incidence were generally similar when analyzed by age (< or ≥65 years) or sex. These data, obtained in an inhalation device-naïve population, suggest that the ELLIPTA DPI is preferred to an established alternative based on its ease-of-use features and is associated with fewer handling errors.
Acute baclofen diminishes resting baseline blood flow to limbic structures: A perfusion fMRI study
Franklin, Teresa R.; Shin, Joshua; Jagannathan, Kanchana; Suh, Jesse J.; Detre, John A.; O’Brien, Charles P.; Childress, Anna Rose
2012-01-01
Background Preclinical and clinical evidence show that the GABA B agonist, baclofen is a promising treatment for addictive disorders; however, until recently its mechanism of action in the human brain was unknown. In previous work we utilized a laboratory model that included a medication versus placebo regimen to examine baclofen’s actions on brain circuitry. Perfusion fMRI [measure of cerebral blood flow (CBF)] data acquired ‘at rest’ before and on the last day of the 21-day medication regimen showed that baclofen diminished CBF bilaterally in the VS, insula and medial orbitofrontal cortex (mOFC). In the present study, we hypothesized that a single dose of baclofen would have effects similar to repeated dosing. Methods To test our hypothesis, in a crossover design, CBF data were acquired using pseudo continuous arterial spin labeled (pCASL) perfusion fMRI. Subjects were either un-medicated or were administered a 20 mg dose of baclofen approximately 110 min prior to scanning. Results Acute baclofen diminished mOFC, amygdala, and ventral anterior insula CBF without causing sedation (family-wise error corrected at p = 0.001). Conclusions Results demonstrate that similar to repeated dosing, an acute dose of baclofen blunts the ‘limbic’ substrate that is hyper-responsive to drugs and drug cues. Smokers often manage their craving and can remain abstinent for extended periods after quitting, however the risk of eventual relapse approaches 90%. Given that chronic medication may not be a practical solution to the long-term risk of relapse, acute baclofen may be useful on an ‘as-needed’ basis to block craving during ‘at risk’ situations. PMID:22513380
Assessment of legibility and completeness of handwritten and electronic prescriptions.
Albarrak, Ahmed I; Al Rashidi, Eman Abdulrahman; Fatani, Rwaa Kamil; Al Ageel, Shoog Ibrahim; Mohammed, Rafiuddin
2014-12-01
To assess the legibility and completeness of handwritten prescriptions and compare with electronic prescription system for medication errors. Prospective study. King Khalid University Hospital (KKUH), Riyadh, Saudi Arabia. Handwritten prescriptions were received from clinical units of Medicine Outpatient Department (MOPD), Primary Care Clinic (PCC) and Surgery Outpatient Department (SOPD) whereas electronic prescriptions were collected from the pediatric ward. The handwritten prescription was assessed for completeness by the checklist designed according to the hospital prescription and evaluated for legibility by two pharmacists. The comparison between handwritten and electronic prescription errors was evaluated based on the validated checklist adopted from previous studies. Legibility and completeness of prescriptions. 398 prescriptions (199 handwritten and 199 e-prescriptions) were assessed. About 71 (35.7%) of handwritten and 5 (2.5%) of electronic prescription errors were identified. A significant statistical difference (P < 0.001) was observed between handwritten and e-prescriptions in omitted dose and omitted route of administration category of error distribution. The rate of completeness in patient identification in handwritten prescriptions was 80.97% in MOPD, 76.36% in PCC and 85.93% in SOPD clinic units. Assessment of medication prescription completeness was 91.48% in MOPD, 88.48% in PCC, and 89.28% in SOPD. This study revealed a high incidence of prescribing errors in handwritten prescriptions. The use of e-prescription system showed a significant decline in the incidence of errors. The legibility of handwritten prescriptions was relatively good whereas the level of completeness was very low.
Shawahna, Ramzi; Masri, Dina; Al-Gharabeh, Rawan; Deek, Rawan; Al-Thayba, Lama; Halaweh, Masa
2016-02-01
To develop and achieve formal consensus on a definition of medication administration errors and scenarios that should or should not be considered as medication administration errors in hospitalised patient settings. Medication administration errors occur frequently in hospitalised patient settings. Currently, there is no formal consensus on a definition of medication administration errors or scenarios that should or should not be considered as medication administration errors. This was a descriptive study using Delphi technique. A panel of experts (n = 50) recruited from major hospitals, nursing schools and universities in Palestine took part in the study. Three Delphi rounds were followed to achieve consensus on a proposed definition of medication administration errors and a series of 61 scenarios representing potential medication administration error situations formulated into a questionnaire. In the first Delphi round, key contact nurses' views on medication administration errors were explored. In the second Delphi round, consensus was achieved to accept the proposed definition of medication administration errors and to include 36 (59%) scenarios and exclude 1 (1·6%) as medication administration errors. In the third Delphi round, consensus was achieved to consider further 14 (23%) and exclude 2 (3·3%) as medication administration errors while the remaining eight (13·1%) were considered equivocal. Of the 61 scenarios included in the Delphi process, experts decided to include 50 scenarios as medication administration errors, exclude three scenarios and include or exclude eight scenarios depending on the individual clinical situation. Consensus on a definition and scenarios representing medication administration errors can be achieved using formal consensus techniques. Researchers should be aware that using different definitions of medication administration errors, inclusion or exclusion of medication administration error situations could significantly affect the rate of medication administration errors reported in their studies. Consensual definitions and medication administration error situations can be used in future epidemiology studies investigating medication administration errors in hospitalised patient settings which may permit and promote direct comparisons of different studies. © 2015 John Wiley & Sons Ltd.
Applying Intelligent Algorithms to Automate the Identification of Error Factors.
Jin, Haizhe; Qu, Qingxing; Munechika, Masahiko; Sano, Masataka; Kajihara, Chisato; Duffy, Vincent G; Chen, Han
2018-05-03
Medical errors are the manifestation of the defects occurring in medical processes. Extracting and identifying defects as medical error factors from these processes are an effective approach to prevent medical errors. However, it is a difficult and time-consuming task and requires an analyst with a professional medical background. The issues of identifying a method to extract medical error factors and reduce the extraction difficulty need to be resolved. In this research, a systematic methodology to extract and identify error factors in the medical administration process was proposed. The design of the error report, extraction of the error factors, and identification of the error factors were analyzed. Based on 624 medical error cases across four medical institutes in both Japan and China, 19 error-related items and their levels were extracted. After which, they were closely related to 12 error factors. The relational model between the error-related items and error factors was established based on a genetic algorithm (GA)-back-propagation neural network (BPNN) model. Additionally, compared to GA-BPNN, BPNN, partial least squares regression and support vector regression, GA-BPNN exhibited a higher overall prediction accuracy, being able to promptly identify the error factors from the error-related items. The combination of "error-related items, their different levels, and the GA-BPNN model" was proposed as an error-factor identification technology, which could automatically identify medical error factors.
Implementation and evaluation of an automated dispensing system.
Schwarz, H O; Brodowy, B A
1995-04-15
An institution's experience in replacing a traditional unit dose cassette-exchange system with an automated dispensing system is described. A 24-hour unit dose cassette-exchange system was replaced with an automated dispensing system (Pyxis's Medstation Rx) on a 36-bed cardiovascular surgery unit and an 8-bed cardiovascular intensive care unit. Significantly fewer missing doses were reported after Medstation Rx was implemented. No conclusions could be made about the impact of the system on the reporting of medication errors. The time savings for pharmacy associated with the filling, checking, and delivery of new medication orders equated to about 0.5 full-time equivalent (FTE). Medstation Rx also saved substantial nursing time for acquisition of controlled substances and for controlled-substance inventory taking at shift changes. A financial analysis showed that Medstation Rx could save the institution about $1 million over five years if all personnel time savings could be translated into FTE reductions. The automated system was given high marks by the nurses in a survey; 80% wanted to keep the system on their unit. Pilot implementation of an automated dispensing system improved the efficiency of drug distribution over that of the traditional unit dose cassette-exchange system.
March, Christopher A; Steiger, David; Scholl, Gretchen; Mohan, Vishnu; Hersh, William R; Gold, Jeffrey A
2013-01-01
Objective To establish the role of high-fidelity simulation training to test the efficacy and safety of the electronic health record (EHR)–user interface within the intensive care unit (ICU) environment. Design Prospective pilot study. Setting Medical ICU in an academic medical centre. Participants Postgraduate medical trainees. Interventions A 5-day-simulated ICU patient was developed in the EHR including labs, hourly vitals, medication administration, ventilator settings, nursing and notes. Fourteen medical issues requiring recognition and subsequent changes in management were included. Issues were chosen based on their frequency of occurrence within the ICU and their ability to test different aspects of the EHR–user interface. ICU residents, blinded to the presence of medical errors within the case, were provided a sign-out and given 10 min to review the case in the EHR. They then presented the case with their management suggestions to an attending physician. Participants were graded on the number of issues identified. All participants were provided with immediate feedback upon completion of the simulation. Primary and secondary outcomes To determine the frequency of error recognition in an EHR simulation. To determine factors associated with improved performance in the simulation. Results 38 participants including 9 interns, 10 residents and 19 fellows were tested. The average error recognition rate was 41% (range 6–73%), which increased slightly with the level of training (35%, 41% and 50% for interns, residents, and fellows, respectively). Over-sedation was the least-recognised error (16%); poor glycemic control was most often recognised (68%). Only 32% of the participants recognised inappropriate antibiotic dosing. Performance correlated with the total number of screens used (p=0.03). Conclusions Despite development of comprehensive EHRs, there remain significant gaps in identifying dangerous medical management issues. This gap remains despite high levels of medical training, suggesting that EHR-specific training may be beneficial. Simulation provides a novel tool in order to both identify these gaps as well as foster EHR-specific training. PMID:23578685
Prevalence and cost of hospital medical errors in the general and elderly United States populations.
Mallow, Peter J; Pandya, Bhavik; Horblyuk, Ruslan; Kaplan, Harold S
2013-12-01
The primary objective of this study was to quantify the differences in the prevalence rate and costs of hospital medical errors between the general population and an elderly population aged ≥65 years. Methods from an actuarial study of medical errors were modified to identify medical errors in the Premier Hospital Database using data from 2009. Visits with more than four medical errors were removed from the population to avoid over-estimation of cost. Prevalence rates were calculated based on the total number of inpatient visits. There were 3,466,596 total inpatient visits in 2009. Of these, 1,230,836 (36%) occurred in people aged ≥ 65. The prevalence rate was 49 medical errors per 1000 inpatient visits in the general cohort and 79 medical errors per 1000 inpatient visits for the elderly cohort. The top 10 medical errors accounted for more than 80% of the total in the general cohort and the 65+ cohort. The most costly medical error for the general population was postoperative infection ($569,287,000). Pressure ulcers were most costly ($347,166,257) in the elderly population. This study was conducted with a hospital administrative database, and assumptions were necessary to identify medical errors in the database. Further, there was no method to identify errors of omission or misdiagnoses within the database. This study indicates that prevalence of hospital medical errors for the elderly is greater than the general population and the associated cost of medical errors in the elderly population is quite substantial. Hospitals which further focus their attention on medical errors in the elderly population may see a significant reduction in costs due to medical errors as a disproportionate percentage of medical errors occur in this age group.
Hale, Martin E; Moe, Derek; Bond, Mary; Gasior, Maciej; Malamut, Richard
2016-10-01
Misuse, abuse and diversion of prescription opioid analgesics represent a global public health concern. The development of abuse-deterrent formulations (ADFs) of prescription opioid analgesics is an important step toward reducing abuse and diversion of these medications, as well as potentially limiting medical consequences when misused or administered in error. ADFs aim to hinder extraction of the active ingredient, prevent administration through alternative routes and/or make abuse of the manipulated product less attractive, less rewarding or aversive. However, opioid ADFs may still be abused via the intended route of administration by increasing the dose and/or dosing frequency. The science of abuse deterrence and the regulatory landscape are still relatively new and evolving. This paper reviews the current status of opioid ADFs, with particular focus on different approaches that can be used to deter abuse, regulatory considerations and implications for clinical management.
Errors introduced by dose scaling for relative dosimetry
Watanabe, Yoichi; Hayashi, Naoki
2012-01-01
Some dosimeters require a relationship between detector signal and delivered dose. The relationship (characteristic curve or calibration equation) usually depends on the environment under which the dosimeters are manufactured or stored. To compensate for the difference in radiation response among different batches of dosimeters, the measured dose can be scaled by normalizing the measured dose to a specific dose. Such a procedure, often called “relative dosimetry”, allows us to skip the time‐consuming production of a calibration curve for each irradiation. In this study, the magnitudes of errors due to the dose scaling procedure were evaluated by using the characteristic curves of BANG3 polymer gel dosimeter, radiographic EDR2 films, and GAFCHROMIC EBT2 films. Several sets of calibration data were obtained for each type of dosimeters, and a calibration equation of one set of data was used to estimate doses of the other dosimeters from different batches. The scaled doses were then compared with expected doses, which were obtained by using the true calibration equation specific to each batch. In general, the magnitude of errors increased with increasing deviation of the dose scaling factor from unity. Also, the errors strongly depended on the difference in the shape of the true and reference calibration curves. For example, for the BANG3 polymer gel, of which the characteristic curve can be approximated with a linear equation, the error for a batch requiring a dose scaling factor of 0.87 was larger than the errors for other batches requiring smaller magnitudes of dose scaling, or scaling factors of 0.93 or 1.02. The characteristic curves of EDR2 and EBT2 films required nonlinear equations. With those dosimeters, errors larger than 5% were commonly observed in the dose ranges of below 50% and above 150% of the normalization dose. In conclusion, the dose scaling for relative dosimetry introduces large errors in the measured doses when a large dose scaling is applied, and this procedure should be applied with special care. PACS numbers: 87.56.Da, 06.20.Dk, 06.20.fb PMID:22955658
Defining quality metrics and improving safety and outcome in allergy care.
Lee, Stella; Stachler, Robert J; Ferguson, Berrylin J
2014-04-01
The delivery of allergy immunotherapy in the otolaryngology office is variable and lacks standardization. Quality metrics encompasses the measurement of factors associated with good patient-centered care. These factors have yet to be defined in the delivery of allergy immunotherapy. We developed and applied quality metrics to 6 allergy practices affiliated with an academic otolaryngic allergy center. This work was conducted at a tertiary academic center providing care to over 1500 patients. We evaluated methods and variability between 6 sites. Tracking of errors and anaphylaxis was initiated across all sites. A nationwide survey of academic and private allergists was used to collect data on current practice and use of quality metrics. The most common types of errors recorded were patient identification errors (n = 4), followed by vial mixing errors (n = 3), and dosing errors (n = 2). There were 7 episodes of anaphylaxis of which 2 were secondary to dosing errors for a rate of 0.01% or 1 in every 10,000 injection visits/year. Site visits showed that 86% of key safety measures were followed. Analysis of nationwide survey responses revealed that quality metrics are still not well defined by either medical or otolaryngic allergy practices. Academic practices were statistically more likely to use quality metrics (p = 0.021) and perform systems reviews and audits in comparison to private practices (p = 0.005). Quality metrics in allergy delivery can help improve safety and quality care. These metrics need to be further defined by otolaryngic allergists in the changing health care environment. © 2014 ARS-AAOA, LLC.
Medication management of febrile children: a qualitative study on pharmacy employees' experiences.
Stakenborg, Jacqueline P G; de Bont, Eefje G P M; Peetoom, Kirsten K B; Nelissen-Vrancken, Marjorie H J M G; Cals, Jochen W L
2016-10-01
Background While fever is mostly self-limiting, antibiotic prescription rates for febrile children are high. Although every parent who receives a prescription visits a pharmacy, we have limited insight into pharmacy employees' experiences with these parents. Pharmacy employees do however exert an important role in ensuring children receive correct dosages and in advising parents on administration of antibiotics. Objective To describe pharmacists' and pharmacy assistants' experiences with parents contacting a pharmacy for their febrile child, and to identify ways of improving medication management of these children. Setting Community pharmacies in the Netherlands. Method A qualitative study including 24 Dutch pharmacy employees was conducted, performing four focus group discussions among pharmacy employees. Analysis was based on constant comparative technique using open and axial coding. Main outcome measure Pharmacy employees' experiences with parents contacting a pharmacy for their febrile child. Results Three categories were identified: (1) workload and general experience, (2) inconsistent information on antibiotic prescriptions, (3) improving communication and collaboration. Pharmacy employees experienced that dosing errors in antibiotic prescriptions occur frequently and doctors provide inconsistent information on prescriptions. Consequently, they have to contact doctors, resulting in a higher workload for both stakeholders. They believe this can be improved by providing the indication for antibiotics on prescriptions, especially when deviating from standard dosages. Conclusion Pharmacy employees experience a high amount of dosing errors in paediatric antibiotic prescriptions. Providing the indication for antibiotics in febrile children on prescriptions, especially when deviating from standard dosages, can potentially reduce dosage errors and miscommunication between doctors and pharmacy employees.
Rate, causes and reporting of medication errors in Jordan: nurses' perspectives.
Mrayyan, Majd T; Shishani, Kawkab; Al-Faouri, Ibrahim
2007-09-01
The aim of the study was to describe Jordanian nurses' perceptions about various issues related to medication errors. This is the first nursing study about medication errors in Jordan. This was a descriptive study. A convenient sample of 799 nurses from 24 hospitals was obtained. Descriptive and inferential statistics were used for data analysis. Over the course of their nursing career, the average number of recalled committed medication errors per nurse was 2.2. Using incident reports, the rate of medication errors reported to nurse managers was 42.1%. Medication errors occurred mainly when medication labels/packaging were of poor quality or damaged. Nurses failed to report medication errors because they were afraid that they might be subjected to disciplinary actions or even lose their jobs. In the stepwise regression model, gender was the only predictor of medication errors in Jordan. Strategies to reduce or eliminate medication errors are required.
Medication errors: an overview for clinicians.
Wittich, Christopher M; Burkle, Christopher M; Lanier, William L
2014-08-01
Medication error is an important cause of patient morbidity and mortality, yet it can be a confusing and underappreciated concept. This article provides a review for practicing physicians that focuses on medication error (1) terminology and definitions, (2) incidence, (3) risk factors, (4) avoidance strategies, and (5) disclosure and legal consequences. A medication error is any error that occurs at any point in the medication use process. It has been estimated by the Institute of Medicine that medication errors cause 1 of 131 outpatient and 1 of 854 inpatient deaths. Medication factors (eg, similar sounding names, low therapeutic index), patient factors (eg, poor renal or hepatic function, impaired cognition, polypharmacy), and health care professional factors (eg, use of abbreviations in prescriptions and other communications, cognitive biases) can precipitate medication errors. Consequences faced by physicians after medication errors can include loss of patient trust, civil actions, criminal charges, and medical board discipline. Methods to prevent medication errors from occurring (eg, use of information technology, better drug labeling, and medication reconciliation) have been used with varying success. When an error is discovered, patients expect disclosure that is timely, given in person, and accompanied with an apology and communication of efforts to prevent future errors. Learning more about medication errors may enhance health care professionals' ability to provide safe care to their patients. Copyright © 2014 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Quality Assurance: Patient Chart Reviews
NASA Astrophysics Data System (ADS)
Oginni, B. M.; Odero, D. O.
2009-07-01
Recent developments in radiation therapy have immensely impacted the way the radiation dose is delivered to patients undergoing radiation treatments. However, the fundamental quality assurance (QA) issues underlying the radiation therapy still remain the accuracy of the radiation dose and the radiation safety. One of the major duties of clinical medical physicists in the radiation therapy departments still revolves around ensuring the accuracy of dose delivery to the planning target volume (PTV), the reduction of unintended radiation to normal organs and minimization of the radiation exposure to the medical personnel based on ALARA (as low as reasonably achievable) principle. Many of the errors in radiation therapy can be minimized through a comprehensive program of periodic checks. One of the QA procedures on the patient comes in the form of chart reviews which could be in either electronic or paper-based format. We present the quality assurance procedures that have to be performed on the patient records from the beginning and periodically to the end of the treatment, based on the guidelines from the American Association of Physicists in Medicine (AAPM) and American College of Physicians (ACP).
Economic measurement of medical errors using a hospital claims database.
David, Guy; Gunnarsson, Candace L; Waters, Heidi C; Horblyuk, Ruslan; Kaplan, Harold S
2013-01-01
The primary objective of this study was to estimate the occurrence and costs of medical errors from the hospital perspective. Methods from a recent actuarial study of medical errors were used to identify medical injuries. A visit qualified as an injury visit if at least 1 of 97 injury groupings occurred at that visit, and the percentage of injuries caused by medical error was estimated. Visits with more than four injuries were removed from the population to avoid overestimation of cost. Population estimates were extrapolated from the Premier hospital database to all US acute care hospitals. There were an estimated 161,655 medical errors in 2008 and 170,201 medical errors in 2009. Extrapolated to the entire US population, there were more than 4 million unique injury visits containing more than 1 million unique medical errors each year. This analysis estimated that the total annual cost of measurable medical errors in the United States was $985 million in 2008 and just over $1 billion in 2009. The median cost per error to hospitals was $892 for 2008 and rose to $939 in 2009. Nearly one third of all medical injuries were due to error in each year. Medical errors directly impact patient outcomes and hospitals' profitability, especially since 2008 when Medicare stopped reimbursing hospitals for care related to certain preventable medical errors. Hospitals must rigorously analyze causes of medical errors and implement comprehensive preventative programs to reduce their occurrence as the financial burden of medical errors shifts to hospitals. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Cheung, Stephanie; Hoi, Sannifer; Fernandes, Olavo; Huh, Jin; Kynicos, Sara; Murphy, Laura; Lowe, Donna
2018-04-01
Dangerous abbreviations on the Institute for Safe Medication Practices Canada's "Do Not Use" list have resulted in medication errors leading to harm. Data comparing rates of use of dangerous abbreviations in paper and electronic medication orders are limited. To compare rates of use of dangerous abbreviations from the "Do Not Use" list, in paper and electronic medication orders. Secondary objectives include determining the proportion of patients at risk for medication errors due to dangerous abbreviations and the most commonly used dangerous abbreviations. One-day cross-sectional audits of medication orders were conducted at a 6-site hospital network in Toronto, Canada, between December 2013 and January 2014. Proportions of paper and electronic medication orders containing dangerous abbreviation(s) were compared using a χ 2 test. The proportion of patients with at least 1 medication order containing dangerous abbreviation(s) and the top 5 dangerous abbreviations used were described. Overall, 255 patient charts were reviewed. The proportions of paper and electronic medication orders containing dangerous abbreviation(s) were 172/714 (24.1%) and 9/2207 (0.4%), respectively ( P < 0.001). Almost one-third of patients had medication order(s) containing dangerous abbreviation(s). The proportions of patients with at least 1 medication order during the audit period containing dangerous abbreviation(s) for patients with paper only, electronic only, or a hybrid of paper and electronic medication orders were 50.5%, 5%, and 47.2%, respectively. Those most commonly used were "D/C", drug name abbreviations, "OD," "cc," and "U." Electronic medication orders have significantly lower rates of dangerous abbreviation use compared to paper medication orders.
Hicks, Rodney W; Becker, Shawn C
2006-01-01
Medication errors can be harmful, especially if they involve the intravenous (IV) route of administration. A mixed-methodology study using a 5-year review of 73,769 IV-related medication errors from a national medication error reporting program indicates that between 3% and 5% of these errors were harmful. The leading type of error was omission, and the leading cause of error involved clinician performance deficit. Using content analysis, three themes-product shortage, calculation errors, and tubing interconnectivity-emerge and appear to predispose patients to harm. Nurses often participate in IV therapy, and these findings have implications for practice and patient safety. Voluntary medication error-reporting programs afford an opportunity to improve patient care and to further understanding about the nature of IV-related medication errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop adaptive planning with feedback for MRI-guided focal HDR prostate brachytherapy with a single divergent needle robotic implant device. After each needle insertion, the dwell positions for that needle are calculated and the positioning of remaining needles and dosimetry are both updated based on MR imaging. Methods: Errors in needle positioning may occur due to inaccurate needle insertion (caused by e.g. the needle’s bending) and unpredictable changes in patient anatomy. Consequently, the dose plan quality might dramatically decrease compared to the preplan. In this study, a procedure was developed to re-optimize, after each needle insertion, the remaining needlemore » angulations, source positions and dwell times in order to obtain an optimal coverage (D95% PTV>19 Gy) without exceeding the constraints of the organs at risk (OAR) (D10% urethra<21 Gy, D1cc bladder<12 Gy and D1cc rectum<12 Gy). Complete HDR procedures with 6 needle insertions were simulated for a patient MR-image set with PTV, prostate, urethra, bladder and rectum delineated. Random angulation errors, modeled by a Gaussian distribution (standard deviation of 3 mm at the needle’s tip), were generated for each needle insertion. We compared the final dose parameters for the situations (I) without re-optimization and (II) with the automatic feedback. Results: The computation time of replanning was below 100 seconds on a current desk computer. For the patient tested, a clinically acceptable dose plan was achieved while applying the automatic feedback (median(range) in Gy, D95% PTV: 19.9(19.3–20.3), D10% urethra: 13.4(11.9–18.0), D1cc rectum: 11.0(10.7–11.6), D1cc bladder: 4.9(3.6–6.8)). This was not the case without re-optimization (median(range) in Gy, D95% PTV: 19.4(14.9–21.3), D10% urethra: 12.6(11.0–15.7), D1cc rectum: 10.9(8.9–14.1), D1cc bladder: 4.8(4.4–5.2)). Conclusion: An automatic guidance strategy for HDR prostate brachytherapy was developed to compensate errors in needle positioning and improve the dose distribution. Without re-optimization, target coverage and OAR constraints may not be achieved. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are full-time employees of Philips Medical Systems Nederland B.V.« less
Statistical methods for biodosimetry in the presence of both Berkson and classical measurement error
NASA Astrophysics Data System (ADS)
Miller, Austin
In radiation epidemiology, the true dose received by those exposed cannot be assessed directly. Physical dosimetry uses a deterministic function of the source term, distance and shielding to estimate dose. For the atomic bomb survivors, the physical dosimetry system is well established. The classical measurement errors plaguing the location and shielding inputs to the physical dosimetry system are well known. Adjusting for the associated biases requires an estimate for the classical measurement error variance, for which no data-driven estimate exists. In this case, an instrumental variable solution is the most viable option to overcome the classical measurement error indeterminacy. Biological indicators of dose may serve as instrumental variables. Specification of the biodosimeter dose-response model requires identification of the radiosensitivity variables, for which we develop statistical definitions and variables. More recently, researchers have recognized Berkson error in the dose estimates, introduced by averaging assumptions for many components in the physical dosimetry system. We show that Berkson error induces a bias in the instrumental variable estimate of the dose-response coefficient, and then address the estimation problem. This model is specified by developing an instrumental variable mixed measurement error likelihood function, which is then maximized using a Monte Carlo EM Algorithm. These methods produce dose estimates that incorporate information from both physical and biological indicators of dose, as well as the first instrumental variable based data-driven estimate for the classical measurement error variance.
Concomitant prescribing and dispensing errors at a Brazilian hospital: a descriptive study
Silva, Maria das Dores Graciano; Rosa, Mário Borges; Franklin, Bryony Dean; Reis, Adriano Max Moreira; Anchieta, Lêni Márcia; Mota, Joaquim Antônio César
2011-01-01
OBJECTIVE: To analyze the prevalence and types of prescribing and dispensing errors occurring with high-alert medications and to propose preventive measures to avoid errors with these medications. INTRODUCTION: The prevalence of adverse events in health care has increased, and medication errors are probably the most common cause of these events. Pediatric patients are known to be a high-risk group and are an important target in medication error prevention. METHODS: Observers collected data on prescribing and dispensing errors occurring with high-alert medications for pediatric inpatients in a university hospital. In addition to classifying the types of error that occurred, we identified cases of concomitant prescribing and dispensing errors. RESULTS: One or more prescribing errors, totaling 1,632 errors, were found in 632 (89.6%) of the 705 high-alert medications that were prescribed and dispensed. We also identified at least one dispensing error in each high-alert medication dispensed, totaling 1,707 errors. Among these dispensing errors, 723 (42.4%) content errors occurred concomitantly with the prescribing errors. A subset of dispensing errors may have occurred because of poor prescription quality. The observed concomitancy should be examined carefully because improvements in the prescribing process could potentially prevent these problems. CONCLUSION: The system of drug prescribing and dispensing at the hospital investigated in this study should be improved by incorporating the best practices of medication safety and preventing medication errors. High-alert medications may be used as triggers for improving the safety of the drug-utilization system. PMID:22012039
Antidepressant and antipsychotic medication errors reported to United States poison control centers.
Kamboj, Alisha; Spiller, Henry A; Casavant, Marcel J; Chounthirath, Thitphalak; Hodges, Nichole L; Smith, Gary A
2018-05-08
To investigate unintentional therapeutic medication errors associated with antidepressant and antipsychotic medications in the United States and expand current knowledge on the types of errors commonly associated with these medications. A retrospective analysis of non-health care facility unintentional therapeutic errors associated with antidepressant and antipsychotic medications was conducted using data from the National Poison Data System. From 2000 to 2012, poison control centers received 207 670 calls reporting unintentional therapeutic errors associated with antidepressant or antipsychotic medications that occurred outside of a health care facility, averaging 15 975 errors annually. The rate of antidepressant-related errors increased by 50.6% from 2000 to 2004, decreased by 6.5% from 2004 to 2006, and then increased 13.0% from 2006 to 2012. The rate of errors related to antipsychotic medications increased by 99.7% from 2000 to 2004 and then increased by 8.8% from 2004 to 2012. Overall, 70.1% of reported errors occurred among adults, and 59.3% were among females. The medications most frequently associated with errors were selective serotonin reuptake inhibitors (30.3%), atypical antipsychotics (24.1%), and other types of antidepressants (21.5%). Most medication errors took place when an individual inadvertently took or was given a medication twice (41.0%), inadvertently took someone else's medication (15.6%), or took the wrong medication (15.6%). This study provides a comprehensive overview of non-health care facility unintentional therapeutic errors associated with antidepressant and antipsychotic medications. The frequency and rate of these errors increased significantly from 2000 to 2012. Given that use of these medications is increasing in the US, this study provides important information about the epidemiology of the associated medication errors. Copyright © 2018 John Wiley & Sons, Ltd.
On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors.
McVicker, Drew; Yin, Fang-Fang; Adamson, Justus D
2016-01-08
We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical anisotropic algorithm within a commercial treatment planning system. Errors were implemented into the various components of the dose calculation algorithm including primary photons, secondary photons, electron contamination, and MLC parameters. For each error we evaluated the probability that it could be committed unknowingly during the dose algorithm commissioning stage, and the probability of it being identified during the verification stage. The clinical impact of each commissioning error was evaluated using representative IMRT plans including low and intermediate risk prostate, head and neck, mesothelioma, and scalp; the sensitivity of the TG-119 and IROC phantoms was evaluated by comparing dosimetric changes to the dose planes where film measurements occur and change in point doses where dosimeter measurements occur. No commissioning errors were found to have both a low probability of detection and high clinical severity. When errors do occur, the IROC credentialing and TG 119 commissioning criteria are generally effective at detecting them; however, for the IROC phantom, OAR point-dose measurements are the most sensitive despite being currently excluded from IROC analysis. Point-dose measurements with an absolute dose constraint were the most effective at detecting errors, while film analysis using a gamma comparison and the IROC film distance to agreement criteria were less effective at detecting the specific commissioning errors implemented here.
Medication Errors: New EU Good Practice Guide on Risk Minimisation and Error Prevention.
Goedecke, Thomas; Ord, Kathryn; Newbould, Victoria; Brosch, Sabine; Arlett, Peter
2016-06-01
A medication error is an unintended failure in the drug treatment process that leads to, or has the potential to lead to, harm to the patient. Reducing the risk of medication errors is a shared responsibility between patients, healthcare professionals, regulators and the pharmaceutical industry at all levels of healthcare delivery. In 2015, the EU regulatory network released a two-part good practice guide on medication errors to support both the pharmaceutical industry and regulators in the implementation of the changes introduced with the EU pharmacovigilance legislation. These changes included a modification of the 'adverse reaction' definition to include events associated with medication errors, and the requirement for national competent authorities responsible for pharmacovigilance in EU Member States to collaborate and exchange information on medication errors resulting in harm with national patient safety organisations. To facilitate reporting and learning from medication errors, a clear distinction has been made in the guidance between medication errors resulting in adverse reactions, medication errors without harm, intercepted medication errors and potential errors. This distinction is supported by an enhanced MedDRA(®) terminology that allows for coding all stages of the medication use process where the error occurred in addition to any clinical consequences. To better understand the causes and contributing factors, individual case safety reports involving an error should be followed-up with the primary reporter to gather information relevant for the conduct of root cause analysis where this may be appropriate. Such reports should also be summarised in periodic safety update reports and addressed in risk management plans. Any risk minimisation and prevention strategy for medication errors should consider all stages of a medicinal product's life-cycle, particularly the main sources and types of medication errors during product development. This article describes the key concepts of the EU good practice guidance for defining, classifying, coding, reporting, evaluating and preventing medication errors. This guidance should contribute to the safe and effective use of medicines for the benefit of patients and public health.
Corlett, Philip R; Honey, Garry D; Aitken, Michael R F; Dickinson, Anthony; Shanks, David R; Absalom, Anthony R; Lee, Michael; Pomarol-Clotet, Edith; Murray, Graham K; McKenna, Peter J; Robbins, Trevor W; Bullmore, Edward T; Fletcher, Paul C
2006-06-01
Establishing a neurobiological account of delusion formation that links cognitive processes, brain activity, and symptoms is important to furthering our understanding of psychosis. To explore a theoretical model of delusion formation that implicates prediction error-dependent associative learning processes in a pharmacological functional magnetic resonance imaging study using the psychotomimetic drug ketamine. Within-subject, randomized, placebo-controlled study. Hospital-based clinical research facility, Addenbrooke's Hospital, Cambridge, England. The work was completed within the Wellcome Trust and Medical Research Council Behavioral and Clinical Neuroscience Institute, Cambridge. Fifteen healthy, right-handed volunteers (8 of whom were male) with a mean +/- SD age of 29 +/- 7 years and a mean +/- SD predicted full-scale IQ of 113 +/- 4 were recruited from within the local community by advertisement. Subjects were given low-dose ketamine (100 ng/mL of plasma) or placebo while performing a causal associative learning task during functional magnetic resonance imaging. In a separate session outside the scanner, the dose was increased (to 200 ng/mL of plasma) and subjects underwent a structured clinical interview. Brain activation, blood plasma levels of ketamine, and scores from psychiatric ratings scales (Brief Psychiatric Ratings Scale, Present State Examination, and Clinician-Administered Dissociative States Scale). Low-dose ketamine perturbs error-dependent learning activity in the right frontal cortex (P = .03). High-dose ketamine produces perceptual aberrations (P = .01) and delusion-like beliefs (P = .007). Critically, subjects showing the highest degree of frontal activation with placebo show the greatest occurrence of drug-induced perceptual aberrations (P = .03) and ideas or delusions of reference (P = .04). These findings relate aberrant prediction error-dependent associative learning to referential ideas and delusions via a perturbation of frontal cortical function. They are consistent with a model of delusion formation positing disruptions in error-dependent learning.
An Improved Method of Heterogeneity Compensation for the Convolution / Superposition Algorithm
NASA Astrophysics Data System (ADS)
Jacques, Robert; McNutt, Todd
2014-03-01
Purpose: To improve the accuracy of convolution/superposition (C/S) in heterogeneous material by developing a new algorithm: heterogeneity compensated superposition (HCS). Methods: C/S has proven to be a good estimator of the dose deposited in a homogeneous volume. However, near heterogeneities electron disequilibrium occurs, leading to the faster fall-off and re-buildup of dose. We propose to filter the actual patient density in a position and direction sensitive manner, allowing the dose deposited near interfaces to be increased or decreased relative to C/S. We implemented the effective density function as a multivariate first-order recursive filter and incorporated it into GPU-accelerated, multi-energetic C/S implementation. We compared HCS against C/S using the ICCR 2000 Monte-Carlo accuracy benchmark, 23 similar accuracy benchmarks and 5 patient cases. Results: Multi-energetic HCS increased the dosimetric accuracy for the vast majority of voxels; in many cases near Monte-Carlo results were achieved. We defined the per-voxel error, %|mm, as the minimum of the distance to agreement in mm and the dosimetric percentage error relative to the maximum MC dose. HCS improved the average mean error by 0.79 %|mm for the patient volumes; reducing the average mean error from 1.93 %|mm to 1.14 %|mm. Very low densities (i.e. < 0.1 g / cm3) remained problematic, but may be solvable with a better filter function. Conclusions: HCS improved upon C/S's density scaled heterogeneity correction with a position and direction sensitive density filter. This method significantly improved the accuracy of the GPU based algorithm reaching the accuracy levels of Monte Carlo based methods with performance in a few tenths of seconds per beam. Acknowledgement: Funding for this research was provided by the NSF Cooperative Agreement EEC9731748, Elekta / IMPAC Medical Systems, Inc. and the Johns Hopkins University. James Satterthwaite provided the Monte Carlo benchmark simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chengqiang, L; Yin, Y; Chen, L
Purpose: To investigate the impact of MLC position errors on simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for patients with nasopharyngeal carcinoma. Methods: To compare the dosimetric differences between the simulated plans and the clinical plans, ten patients with locally advanced NPC treated with SIB-IMRT were enrolled in this study. All plans were calculated with an inverse planning system (Pinnacle3, Philips Medical System{sub )}. Random errors −2mm to 2mm{sub )},shift errors{sub (} 2mm,1mm and 0.5mm) and systematic extension/ contraction errors (±2mm, ±1mm and ±0.5mm) of the MLC leaf position were introduced respectively into the original plans to create the simulated plans.more » Dosimetry factors were compared between the original and the simulated plans. Results: The dosimetric impact of the random and system shift errors of MLC position was insignificant within 2mm, the maximum changes in D95% of PGTV,PTV1,PTV2 were-0.92±0.51%,1.00±0.24% and 0.62±0.17%, the maximum changes in the D0.1cc of spinal cord and brainstem were 1.90±2.80% and −1.78±1.42%, the maximum changes in the Dmean of parotids were1.36±1.23% and −2.25±2.04%.However,the impact of MLC extension or contraction errors was found significant. For 2mm leaf extension errors, the average changes in D95% of PGTV,PTV1,PTV2 were 4.31±0.67%,4.29±0.65% and 4.79±0.82%, the averaged value of the D0.1cc to spinal cord and brainstem were increased by 7.39±5.25% and 6.32±2.28%,the averaged value of the mean dose to left and right parotid were increased by 12.75±2.02%,13.39±2.17% respectively. Conclusion: The dosimetric effect was insignificant for random MLC leaf position errors up to 2mm. There was a high sensitivity to dose distribution for MLC extension or contraction errors.We should pay attention to the anatomic changes in target organs and anatomical structures during the course,individual radiotherapy was recommended to ensure adaptive doses.« less
A description of medication errors reported by pharmacists in a neonatal intensive care unit.
Pawluk, Shane; Jaam, Myriam; Hazi, Fatima; Al Hail, Moza Sulaiman; El Kassem, Wessam; Khalifa, Hanan; Thomas, Binny; Abdul Rouf, Pallivalappila
2017-02-01
Background Patients in the Neonatal Intensive Care Unit (NICU) are at an increased risk for medication errors. Objective The objective of this study is to describe the nature and setting of medication errors occurring in patients admitted to an NICU in Qatar based on a standard electronic system reported by pharmacists. Setting Neonatal intensive care unit, Doha, Qatar. Method This was a retrospective cross-sectional study on medication errors reported electronically by pharmacists in the NICU between January 1, 2014 and April 30, 2015. Main outcome measure Data collected included patient information, and incident details including error category, medications involved, and follow-up completed. Results A total of 201 NICU pharmacists-reported medication errors were submitted during the study period. All reported errors did not reach the patient and did not cause harm. Of the errors reported, 98.5% occurred in the prescribing phase of the medication process with 58.7% being due to calculation errors. Overall, 53 different medications were documented in error reports with the anti-infective agents being the most frequently cited. The majority of incidents indicated that the primary prescriber was contacted and the error was resolved before reaching the next phase of the medication process. Conclusion Medication errors reported by pharmacists occur most frequently in the prescribing phase of the medication process. Our data suggest that error reporting systems need to be specific to the population involved. Special attention should be paid to frequently used medications in the NICU as these were responsible for the greatest numbers of medication errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lobb, Eric, E-mail: eclobb2@gmail.com
2014-04-01
The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneitymore » index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Juan; Beltran, Chris J., E-mail: beltran.chris@mayo.edu; Herman, Michael G.
Purpose: To quantitatively and systematically assess dosimetric effects induced by spot positioning error as a function of spot spacing (SS) on intensity-modulated proton therapy (IMPT) plan quality and to facilitate evaluation of safety tolerance limits on spot position. Methods: Spot position errors (PE) ranging from 1 to 2 mm were simulated. Simple plans were created on a water phantom, and IMPT plans were calculated on two pediatric patients with a brain tumor of 28 and 3 cc, respectively, using a commercial planning system. For the phantom, a uniform dose was delivered to targets located at different depths from 10 tomore » 20 cm with various field sizes from 2{sup 2} to 15{sup 2} cm{sup 2}. Two nominal spot sizes, 4.0 and 6.6 mm of 1 σ in water at isocenter, were used for treatment planning. The SS ranged from 0.5 σ to 1.5 σ, which is 2–6 mm for the small spot size and 3.3–9.9 mm for the large spot size. Various perturbation scenarios of a single spot error and systematic and random multiple spot errors were studied. To quantify the dosimetric effects, percent dose error (PDE) depth profiles and the value of percent dose error at the maximum dose difference (PDE [ΔDmax]) were used for evaluation. Results: A pair of hot and cold spots was created per spot shift. PDE[ΔDmax] is found to be a complex function of PE, SS, spot size, depth, and global spot distribution that can be well defined in simple models. For volumetric targets, the PDE [ΔDmax] is not noticeably affected by the change of field size or target volume within the studied ranges. In general, reducing SS decreased the dose error. For the facility studied, given a single spot error with a PE of 1.2 mm and for both spot sizes, a SS of 1σ resulted in a 2% maximum dose error; a SS larger than 1.25 σ substantially increased the dose error and its sensitivity to PE. A similar trend was observed in multiple spot errors (both systematic and random errors). Systematic PE can lead to noticeable hot spots along the field edges, which may be near critical structures. However, random PE showed minimal dose error. Conclusions: Dose error dependence for PE was quantitatively and systematically characterized and an analytic tool was built to simulate systematic and random errors for patient-specific IMPT. This information facilitates the determination of facility specific spot position error thresholds.« less
Baldwin, Keith; Namdari, Surena; Donegan, Derek; Kamath, Atul F; Mehta, Samir
2011-01-19
since the inception of the eighty-hour work week, work hour restrictions have incited considerable debate. Work hour policies were designed to prevent medical errors and to reduce patient morbidity and mortality. It is unclear whether work hour restrictions have been helpful in medicine in general and in orthopaedic surgery specifically. This systematic review of the literature was designed to determine the success of these restrictions in terms of patient mortality, medical errors, and complications. a systematic review of the literature was performed to determine if work hour rules have improved patient and systems-based outcomes and reduced physician errors as measured by mortality, medical errors, and complications. A random effects model was utilized to determine whether patient mortality rates were improved under the new rules. the odds of patient death before implementation of the work hour rules were 1.12 (95% confidence interval, 1.07 to 1.17) times those after implementation. These differences were consistent across disciplines. The data concerning medical or surgical complications before and after the institution of the work hour rules were mixed. There was little information in these studies concerning direct medical errors. The odds of death in nonteaching cohorts were not significantly different from that in teaching cohorts. there appears to be a decrease in mortality following the institution of work hour rules. The difference seen in teaching cohorts is not significantly different from that in nonteaching cohorts. It is unclear whether this difference would have been observed even without work hour restrictions. No study has shown a reduction in mortality for orthopaedic patients in teaching cohorts that was greater than that observed in nonteaching cohorts. Because of methodological concerns and the lack of current literature linking physician fatigue and physician underperformance with patient mortality, it is unclear whether the goals of the work hour reductions have been achieved. Furthermore, because of a lack of a so-called dose-response relationship between work hour reduction and patient mortality, it is uncertain whether further reductions would be beneficial. therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.
TU-H-CAMPUS-JeP1-05: Dose Deformation Error Associated with Deformable Image Registration Pathways
DOE Office of Scientific and Technical Information (OSTI.GOV)
Surucu, M; Woerner, A; Roeske, J
Purpose: To evaluate errors associated with using different deformable image registration (DIR) pathways to deform dose from planning CT (pCT) to cone-beam CT (CBCT). Methods: Deforming dose is controversial because of the lack of quality assurance tools. We previously proposed a novel metric to evaluate dose deformation error (DDE) by warping dose information using two methods, via dose and contour deformation. First, isodose lines of the pCT were converted into structures and then deformed to the CBCT using an image based deformation map (dose/structure/deform). Alternatively, the dose matrix from the pCT was deformed to CBCT using the same deformation map,more » and then the same isodose lines of the deformed dose were converted into structures (dose/deform/structure). The doses corresponding to each structure were queried from the deformed dose and full-width-half-maximums were used to evaluate the dose dispersion. The difference between the FWHM of each isodose level structure is defined as the DDE. Three head-and-neck cancer patients were identified. For each patient, two DIRs were performed between the pCT and CBCT, either deforming pCT-to-CBCT or CBCT-to-pCT. We evaluated the errors associated by using either of these pathways to deform dose. A commercially available, Demons based DIR was used for this study, and 10 isodose levels (20% to 105%) were used to evaluate the errors in various dose levels. Results: The prescription dose for all patients was 70 Gy. The mean DDE for CT-to-CBCT deformation was 1.0 Gy (range: 0.3–2.0 Gy) and this was increased to 4.3 Gy (range: 1.5–6.4 Gy) for CBCT-to-CT deformation. The mean increase in DDE between the two deformations was 3.3 Gy (range: 1.0–5.4 Gy). Conclusion: The proposed DDF was used to quantitatively estimate dose deformation errors caused by different pathways to perform DIR. Deforming dose using CBCT-to-CT deformation produced greater error than CT-to-CBCT deformation.« less
Knights, Jonathan; Rohatagi, Shashank
2015-12-01
Although there is a body of literature focused on minimizing the effect of dosing inaccuracies on pharmacokinetic (PK) parameter estimation, most of the work centers on missing doses. No attempt has been made to specifically characterize the effect of error in reported dosing times. Additionally, existing work has largely dealt with cases in which the compound of interest is dosed at an interval no less than its terminal half-life. This work provides a case study investigating how error in patient reported dosing times might affect the accuracy of structural model parameter estimation under sparse sampling conditions when the dosing interval is less than the terminal half-life of the compound, and the underlying kinetics are monoexponential. Additional effects due to noncompliance with dosing events are not explored and it is assumed that the structural model and reasonable initial estimates of the model parameters are known. Under the conditions of our simulations, with structural model CV % ranging from ~20 to 60 %, parameter estimation inaccuracy derived from error in reported dosing times was largely controlled around 10 % on average. Given that no observed dosing was included in the design and sparse sampling was utilized, we believe these error results represent a practical ceiling given the variability and parameter estimates for the one-compartment model. The findings suggest additional investigations may be of interest and are noteworthy given the inability of current PK software platforms to accommodate error in dosing times.
Effects of learning climate and registered nurse staffing on medication errors.
Chang, Yunkyung; Mark, Barbara
2011-01-01
Despite increasing recognition of the significance of learning from errors, little is known about how learning climate contributes to error reduction. The purpose of this study was to investigate whether learning climate moderates the relationship between error-producing conditions and medication errors. A cross-sectional descriptive study was done using data from 279 nursing units in 146 randomly selected hospitals in the United States. Error-producing conditions included work environment factors (work dynamics and nurse mix), team factors (communication with physicians and nurses' expertise), personal factors (nurses' education and experience), patient factors (age, health status, and previous hospitalization), and medication-related support services. Poisson models with random effects were used with the nursing unit as the unit of analysis. A significant negative relationship was found between learning climate and medication errors. It also moderated the relationship between nurse mix and medication errors: When learning climate was negative, having more registered nurses was associated with fewer medication errors. However, no relationship was found between nurse mix and medication errors at either positive or average levels of learning climate. Learning climate did not moderate the relationship between work dynamics and medication errors. The way nurse mix affects medication errors depends on the level of learning climate. Nursing units with fewer registered nurses and frequent medication errors should examine their learning climate. Future research should be focused on the role of learning climate as related to the relationships between nurse mix and medication errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nose, Takayuki, E-mail: nose-takayuki@nms.ac.jp; Chatani, Masashi; Otani, Yuki
Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images aremore » degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.« less
Nose, Takayuki; Chatani, Masashi; Otani, Yuki; Teshima, Teruki; Kumita, Shinichirou
2017-03-15
High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use. Copyright © 2016 Elsevier Inc. All rights reserved.
Medical students' experiences with medical errors: an analysis of medical student essays.
Martinez, William; Lo, Bernard
2008-07-01
This study aimed to examine medical students' experiences with medical errors. In 2001 and 2002, 172 fourth-year medical students wrote an anonymous description of a significant medical error they had witnessed or committed during their clinical clerkships. The assignment represented part of a required medical ethics course. We analysed 147 of these essays using thematic content analysis. Many medical students made or observed significant errors. In either situation, some students experienced distress that seemingly went unaddressed. Furthermore, this distress was sometimes severe and persisted after the initial event. Some students also experienced considerable uncertainty as to whether an error had occurred and how to prevent future errors. Many errors may not have been disclosed to patients, and some students who desired to discuss or disclose errors were apparently discouraged from doing so by senior doctors. Some students criticised senior doctors who attempted to hide errors or avoid responsibility. By contrast, students who witnessed senior doctors take responsibility for errors and candidly disclose errors to patients appeared to recognise the importance of honesty and integrity and said they aspired to these standards. There are many missed opportunities to teach students how to respond to and learn from errors. Some faculty members and housestaff may at times respond to errors in ways that appear to contradict professional standards. Medical educators should increase exposure to exemplary responses to errors and help students to learn from and cope with errors.
Knowledge of healthcare professionals about medication errors in hospitals
Abdel-Latif, Mohamed M. M.
2016-01-01
Context: Medication errors are the most common types of medical errors in hospitals and leading cause of morbidity and mortality among patients. Aims: The aim of the present study was to assess the knowledge of healthcare professionals about medication errors in hospitals. Settings and Design: A self-administered questionnaire was distributed to randomly selected healthcare professionals in eight hospitals in Madinah, Saudi Arabia. Subjects and Methods: An 18-item survey was designed and comprised questions on demographic data, knowledge of medication errors, availability of reporting systems in hospitals, attitudes toward error reporting, causes of medication errors. Statistical Analysis Used: Data were analyzed with Statistical Package for the Social Sciences software Version 17. Results: A total of 323 of healthcare professionals completed the questionnaire with 64.6% response rate of 138 (42.72%) physicians, 34 (10.53%) pharmacists, and 151 (46.75%) nurses. A majority of the participants had a good knowledge about medication errors concept and their dangers on patients. Only 68.7% of them were aware of reporting systems in hospitals. Healthcare professionals revealed that there was no clear mechanism available for reporting of errors in most hospitals. Prescribing (46.5%) and administration (29%) errors were the main causes of errors. The most frequently encountered medication errors were anti-hypertensives, antidiabetics, antibiotics, digoxin, and insulin. Conclusions: This study revealed differences in the awareness among healthcare professionals toward medication errors in hospitals. The poor knowledge about medication errors emphasized the urgent necessity to adopt appropriate measures to raise awareness about medication errors in Saudi hospitals. PMID:27330261
Objective Assessment of Patient Inhaler User Technique Using an Audio-Based Classification Approach.
Taylor, Terence E; Zigel, Yaniv; Egan, Clarice; Hughes, Fintan; Costello, Richard W; Reilly, Richard B
2018-02-01
Many patients make critical user technique errors when using pressurised metered dose inhalers (pMDIs) which reduce the clinical efficacy of respiratory medication. Such critical errors include poor actuation coordination (poor timing of medication release during inhalation) and inhaling too fast (peak inspiratory flow rate over 90 L/min). Here, we present a novel audio-based method that objectively assesses patient pMDI user technique. The Inhaler Compliance Assessment device was employed to record inhaler audio signals from 62 respiratory patients as they used a pMDI with an In-Check Flo-Tone device attached to the inhaler mouthpiece. Using a quadratic discriminant analysis approach, the audio-based method generated a total frame-by-frame accuracy of 88.2% in classifying sound events (actuation, inhalation and exhalation). The audio-based method estimated the peak inspiratory flow rate and volume of inhalations with an accuracy of 88.2% and 83.94% respectively. It was detected that 89% of patients made at least one critical user technique error even after tuition from an expert clinical reviewer. This method provides a more clinically accurate assessment of patient inhaler user technique than standard checklist methods.
Effect of bar-code technology on the safety of medication administration.
Poon, Eric G; Keohane, Carol A; Yoon, Catherine S; Ditmore, Matthew; Bane, Anne; Levtzion-Korach, Osnat; Moniz, Thomas; Rothschild, Jeffrey M; Kachalia, Allen B; Hayes, Judy; Churchill, William W; Lipsitz, Stuart; Whittemore, Anthony D; Bates, David W; Gandhi, Tejal K
2010-05-06
Serious medication errors are common in hospitals and often occur during order transcription or administration of medication. To help prevent such errors, technology has been developed to verify medications by incorporating bar-code verification technology within an electronic medication-administration system (bar-code eMAR). We conducted a before-and-after, quasi-experimental study in an academic medical center that was implementing the bar-code eMAR. We assessed rates of errors in order transcription and medication administration on units before and after implementation of the bar-code eMAR. Errors that involved early or late administration of medications were classified as timing errors and all others as nontiming errors. Two clinicians reviewed the errors to determine their potential to harm patients and classified those that could be harmful as potential adverse drug events. We observed 14,041 medication administrations and reviewed 3082 order transcriptions. Observers noted 776 nontiming errors in medication administration on units that did not use the bar-code eMAR (an 11.5% error rate) versus 495 such errors on units that did use it (a 6.8% error rate)--a 41.4% relative reduction in errors (P<0.001). The rate of potential adverse drug events (other than those associated with timing errors) fell from 3.1% without the use of the bar-code eMAR to 1.6% with its use, representing a 50.8% relative reduction (P<0.001). The rate of timing errors in medication administration fell by 27.3% (P<0.001), but the rate of potential adverse drug events associated with timing errors did not change significantly. Transcription errors occurred at a rate of 6.1% on units that did not use the bar-code eMAR but were completely eliminated on units that did use it. Use of the bar-code eMAR substantially reduced the rate of errors in order transcription and in medication administration as well as potential adverse drug events, although it did not eliminate such errors. Our data show that the bar-code eMAR is an important intervention to improve medication safety. (ClinicalTrials.gov number, NCT00243373.) 2010 Massachusetts Medical Society
Assessment of legibility and completeness of handwritten and electronic prescriptions
Albarrak, Ahmed I; Al Rashidi, Eman Abdulrahman; Fatani, Rwaa Kamil; Al Ageel, Shoog Ibrahim; Mohammed, Rafiuddin
2014-01-01
Objectives To assess the legibility and completeness of handwritten prescriptions and compare with electronic prescription system for medication errors. Design Prospective study. Setting King Khalid University Hospital (KKUH), Riyadh, Saudi Arabia. Subjects and methods Handwritten prescriptions were received from clinical units of Medicine Outpatient Department (MOPD), Primary Care Clinic (PCC) and Surgery Outpatient Department (SOPD) whereas electronic prescriptions were collected from the pediatric ward. The handwritten prescription was assessed for completeness by the checklist designed according to the hospital prescription and evaluated for legibility by two pharmacists. The comparison between handwritten and electronic prescription errors was evaluated based on the validated checklist adopted from previous studies. Main outcome measures Legibility and completeness of prescriptions. Results 398 prescriptions (199 handwritten and 199 e-prescriptions) were assessed. About 71 (35.7%) of handwritten and 5 (2.5%) of electronic prescription errors were identified. A significant statistical difference (P < 0.001) was observed between handwritten and e-prescriptions in omitted dose and omitted route of administration category of error distribution. The rate of completeness in patient identification in handwritten prescriptions was 80.97% in MOPD, 76.36% in PCC and 85.93% in SOPD clinic units. Assessment of medication prescription completeness was 91.48% in MOPD, 88.48% in PCC, and 89.28% in SOPD. Conclusions This study revealed a high incidence of prescribing errors in handwritten prescriptions. The use of e-prescription system showed a significant decline in the incidence of errors. The legibility of handwritten prescriptions was relatively good whereas the level of completeness was very low. PMID:25561864
NASA Astrophysics Data System (ADS)
Colins, Karen; Li, Liqian; Liu, Yu
2017-05-01
Mass production of widely used semiconductor digital integrated circuits (ICs) has lowered unit costs to the level of ordinary daily consumables of a few dollars. It is therefore reasonable to contemplate the idea of an engineered system that consumes unshielded low-cost ICs for the purpose of measuring gamma radiation dose. Underlying the idea is the premise of a measurable correlation between an observable property of ICs and radiation dose. Accumulation of radiation-damage-induced state changes or error events is such a property. If correct, the premise could make possible low-cost wide-area radiation dose measurement systems, instantiated as wireless sensor networks (WSNs) with unshielded consumable ICs as nodes, communicating error events to a remote base station. The premise has been investigated quantitatively for the first time in laboratory experiments and related analyses performed at the Canadian Nuclear Laboratories. State changes or error events were recorded in real time during irradiation of samples of ICs of different types in a 60Co gamma cell. From the error-event sequences, empirical distribution functions of dose were generated. The distribution functions were inverted and probabilities scaled by total error events, to yield plots of the relationship between dose and error tallies. Positive correlation was observed, and discrete functional dependence of dose quantiles on error tallies was measured, demonstrating the correctness of the premise. The idea of an engineered system that consumes unshielded low-cost ICs in a WSN, for the purpose of measuring gamma radiation dose over wide areas, is therefore tenable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y; Zhang, J; Hu, Q
2014-06-01
Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with intervalmore » of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality especially for children. Unless recalibrated, kV should be constant for all anatomical sites if diagnostic CT scanner is used as a simulator. This work was partially supported by Capital Medical Development Scientific Research Fund of China.« less
Huckels-Baumgart, Saskia; Baumgart, André; Buschmann, Ute; Schüpfer, Guido; Manser, Tanja
2016-12-21
Interruptions and errors during the medication process are common, but published literature shows no evidence supporting whether separate medication rooms are an effective single intervention in reducing interruptions and errors during medication preparation in hospitals. We tested the hypothesis that the rate of interruptions and reported medication errors would decrease as a result of the introduction of separate medication rooms. Our aim was to evaluate the effect of separate medication rooms on interruptions during medication preparation and on self-reported medication error rates. We performed a preintervention and postintervention study using direct structured observation of nurses during medication preparation and daily structured medication error self-reporting of nurses by questionnaires in 2 wards at a major teaching hospital in Switzerland. A volunteer sample of 42 nurses was observed preparing 1498 medications for 366 patients over 17 hours preintervention and postintervention on both wards. During 122 days, nurses completed 694 reporting sheets containing 208 medication errors. After the introduction of the separate medication room, the mean interruption rate decreased significantly from 51.8 to 30 interruptions per hour (P < 0.01), and the interruption-free preparation time increased significantly from 1.4 to 2.5 minutes (P < 0.05). Overall, the mean medication error rate per day was also significantly reduced after implementation of the separate medication room from 1.3 to 0.9 errors per day (P < 0.05). The present study showed the positive effect of a hospital-based intervention; after the introduction of the separate medication room, the interruption and medication error rates decreased significantly.
SU-F-T-431: Dosimetric Validation of Acuros XB Algorithm for Photon Dose Calculation in Water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, L; Yadav, G; Kishore, V
2016-06-15
Purpose: To validate the Acuros XB algorithm implemented in Eclipse Treatment planning system version 11 (Varian Medical System, Inc., Palo Alto, CA, USA) for photon dose calculation. Methods: Acuros XB is a Linear Boltzmann transport equation (LBTE) solver that solves LBTE equation explicitly and gives result equivalent to Monte Carlo. 6MV photon beam from Varian Clinac-iX (2300CD) was used for dosimetric validation of Acuros XB. Percentage depth dose (PDD) and profiles (at dmax, 5, 10, 20 and 30 cm) measurements were performed in water for field size ranging from 2×2,4×4, 6×6, 10×10, 20×20, 30×30 and 40×40 cm{sup 2}. Acuros XBmore » results were compared against measurements and anisotropic analytical algorithm (AAA) algorithm. Results: Acuros XB result shows good agreement with measurements, and were comparable to AAA algorithm. Result for PDD and profiles shows less than one percent difference from measurements, and from calculated PDD and profiles by AAA algorithm for all field size. TPS calculated Gamma error histogram values, average gamma errors in PDD curves before dmax and after dmax were 0.28, 0.15 for Acuros XB and 0.24, 0.17 for AAA respectively, average gamma error in profile curves in central region, penumbra region and outside field region were 0.17, 0.21, 0.42 for Acuros XB and 0.10, 0.22, 0.35 for AAA respectively. Conclusion: The dosimetric validation of Acuros XB algorithms in water medium was satisfactory. Acuros XB algorithm has potential to perform photon dose calculation with high accuracy, which is more desirable for modern radiotherapy environment.« less
Barriers to medication error reporting among hospital nurses.
Rutledge, Dana N; Retrosi, Tina; Ostrowski, Gary
2018-03-01
The study purpose was to report medication error reporting barriers among hospital nurses, and to determine validity and reliability of an existing medication error reporting barriers questionnaire. Hospital medication errors typically occur between ordering of a medication to its receipt by the patient with subsequent staff monitoring. To decrease medication errors, factors surrounding medication errors must be understood; this requires reporting by employees. Under-reporting can compromise patient safety by disabling improvement efforts. This 2017 descriptive study was part of a larger workforce engagement study at a faith-based Magnet ® -accredited community hospital in California (United States). Registered nurses (~1,000) were invited to participate in the online survey via email. Reported here are sample demographics (n = 357) and responses to the 20-item medication error reporting barriers questionnaire. Using factor analysis, four factors that accounted for 67.5% of the variance were extracted. These factors (subscales) were labelled Fear, Cultural Barriers, Lack of Knowledge/Feedback and Practical/Utility Barriers; each demonstrated excellent internal consistency. The medication error reporting barriers questionnaire, originally developed in long-term care, demonstrated good validity and excellent reliability among hospital nurses. Substantial proportions of American hospital nurses (11%-48%) considered specific factors as likely reporting barriers. Average scores on most barrier items were categorised "somewhat unlikely." The highest six included two barriers concerning the time-consuming nature of medication error reporting and four related to nurses' fear of repercussions. Hospitals need to determine the presence of perceived barriers among nurses using questionnaires such as the medication error reporting barriers and work to encourage better reporting. Barriers to medication error reporting make it less likely that nurses will report medication errors, especially errors where patient harm is not apparent or where an error might be hidden. Such under-reporting impedes collection of accurate medication error data and prevents hospitals from changing harmful practices. © 2018 John Wiley & Sons Ltd.
A survey of community members' perceptions of medical errors in Oman
Al-Mandhari, Ahmed S; Al-Shafaee, Mohammed A; Al-Azri, Mohammed H; Al-Zakwani, Ibrahim S; Khan, Mushtaq; Al-Waily, Ahmed M; Rizvi, Syed
2008-01-01
Background Errors have been the concern of providers and consumers of health care services. However, consumers' perception of medical errors in developing countries is rarely explored. The aim of this study is to assess community members' perceptions about medical errors and to analyse the factors affecting this perception in one Middle East country, Oman. Methods Face to face interviews were conducted with heads of 212 households in two villages in North Al-Batinah region of Oman selected because of close proximity to the Sultan Qaboos University (SQU), Muscat, Oman. Participants' perceived knowledge about medical errors was assessed. Responses were coded and categorised. Analyses were performed using Pearson's χ2, Fisher's exact tests, and multivariate logistic regression model wherever appropriate. Results Seventy-eight percent (n = 165) of participants believed they knew what was meant by medical errors. Of these, 34% and 26.5% related medical errors to wrong medications or diagnoses, respectively. Understanding of medical errors was correlated inversely with age and positively with family income. Multivariate logistic regression revealed that a one-year increase in age was associated with a 4% reduction in perceived knowledge of medical errors (CI: 1% to 7%; p = 0.045). The study found that 49% of those who believed they knew the meaning of medical errors had experienced such errors. The most common consequence of the errors was severe pain (45%). Of the 165 informed participants, 49% felt that an uncaring health care professional was the main cause of medical errors. Younger participants were able to list more possible causes of medical errors than were older subjects (Incident Rate Ratio of 0.98; p < 0.001). Conclusion The majority of participants believed they knew the meaning of medical errors. Younger participants were more likely to be aware of such errors and could list one or more causes. PMID:18664245
Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia
2014-11-01
Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in medication verification tasks. These findings can be generalised and adapted to mitigate interruption-related errors in other settings where medication verification and administration are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia
2014-01-01
Background Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. Objective The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. Methods The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Results Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Conclusions Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in medication verification tasks. These findings can be generalised and adapted to mitigate interruption-related errors in other settings where medication verification and administration are required. PMID:24906806
The learning experiences of student nurses in pediatric medication management: a qualitative study.
Lin, Fang-Yi; Wu, Wei-Wen; Lin, Hung-Ru; Lee, Tzu-Ying
2014-05-01
Traditionally, the 'five rights' (right patient, right route, right drug, right time, and right dose) principle is taught to be practiced during every medication administration process. Nursing educators use this principle to evaluate student performance. However, health care unit factors and education system characteristics that can contribute to student errors should not be underestimated. Students often felt stressed when medicating children during clinical practicum. The voices of these students are rarely represented. To understand students' experiences and perceptions of medication administration during their pediatric clinical practicum. A descriptive qualitative study design was adopted. A university in Northern Taiwan. A total of 34 undergraduate students who had completed a pediatric clinical practicum participated in a one-on-one interview. Each student was interviewed according to a semi-structured interview guide and was encouraged to disclose individual feelings and thoughts toward their experiences in pediatric medication administration. Eight themes emerged. The findings suggest that to decrease students' anxiety and increase their competence, pediatric instructors should improve their teaching strategies to better prepare students for clinical training. Providing self-directed learning activities and resources to improve students' familiarity with medication and medication safety knowledge is necessary. Instructors should provide students with a secure environment to discuss their medication errors. The 'nine rights' should be taught in fundamental nursing courses to enhance students' awareness during the medication administration process, and students should continue to practice the 'nine rights' in later pediatric clinical courses. Equal importance should be given to system failures that impact patient safety. © 2013.
[Medication reconciliation at hospital admission: Results and identification of target patients].
San José Ruiz, B; Serrano De Lucas, L; López-Giménez, L R; Baza Martínez, B; Sautua Larreategi, S; Bustinza Txertudi, A; Sebastián Leza, Á; Chirivella Ramón, M T; Fonseca Legrand, J L; de Miguel Cascon, M
2016-06-01
To quantify and to classify the discrepancies between the admission treatment and the usual patient treatment. To determine the variables that predict those patients that will have more benefit from medication reconciliation. A prospective medication reconciliation study was conducted in the Vascular Surgery Unit from March 2014 to December 2014. When the patients were admitted to the Vascular Surgery Unit, they were informed about the study and asked to prepare information about their chronic treatment. The pharmacist then checked their clinical records, outpatient prescriptions, and also interviewed the patient, obtaining the best pharmacotherapeutic history available. The discrepancies with the admission treatment were written into the patient electronic clinical records. Finally, the physician classified the discrepancies, and changed the treatment, if needed. The statistical analysis included a comparison between patients with and without a non-justified discrepancy (NJD). The statistically different characteristics were used to plot Receiver Operating Characteristic curves, in order to determine the sensitivity and the specificity of these variables to select patients with discrepancies. A total of 380 patients were included. There were 845 non-justified, 600 justified non-documented, and 439 justified documented discrepancies. At least one NJD was identified in 293 patients (77%), with 65 patients (17%) having only justified discrepancies, and 22 patients (6%) having no discrepancies. NJD were: different dose, route or schedule (51%), omission (39%), wrong drug (8%) and commission (2%). The variables associated with discrepancies were number of chronic medications drugs and provider of information. In most studies, omission is the most frequent error. In contrast, in our study the most frequent error is different dose, route, or schedule. The variable that allows selecting patients at higher risk of discrepancies is the number of chronic drugs. This risk is also increased if the patients are not the manager of their own medication. Copyright © 2016 SECA. Published by Elsevier Espana. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callan, J.R.; Kelly, R.T.; Quinn, M.L.
1995-05-01
Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices usedmore » in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error.« less
Palmer, Katherine A; Shane, Rita; Wu, Cindy N; Bell, Douglas S; Diaz, Frank; Cook-Wiens, Galen; Jackevicius, Cynthia A
2016-01-01
Objective We sought to assess the potential of a widely available source of electronic medication data to prevent medication history errors and resultant inpatient order errors. Methods We used admission medication history (AMH) data from a recent clinical trial that identified 1017 AMH errors and 419 resultant inpatient order errors among 194 hospital admissions of predominantly older adult patients on complex medication regimens. Among the subset of patients for whom we could access current Surescripts electronic pharmacy claims data (SEPCD), two pharmacists independently assessed error severity and our main outcome, which was whether SEPCD (1) was unrelated to the medication error; (2) probably would not have prevented the error; (3) might have prevented the error; or (4) probably would have prevented the error. Results Seventy patients had both AMH errors and current, accessible SEPCD. SEPCD probably would have prevented 110 (35%) of 315 AMH errors and 46 (31%) of 147 resultant inpatient order errors. When we excluded the least severe medication errors, SEPCD probably would have prevented 99 (47%) of 209 AMH errors and 37 (61%) of 61 resultant inpatient order errors. SEPCD probably would have prevented at least one AMH error in 42 (60%) of 70 patients. Conclusion When current SEPCD was available for older adult patients on complex medication regimens, it had substantial potential to prevent AMH errors and resultant inpatient order errors, with greater potential to prevent more severe errors. Further study is needed to measure the benefit of SEPCD in actual use at hospital admission. PMID:26911817
Technology and medication errors: impact in nursing homes.
Baril, Chantal; Gascon, Viviane; St-Pierre, Liette; Lagacé, Denis
2014-01-01
The purpose of this paper is to study a medication distribution technology's (MDT) impact on medication errors reported in public nursing homes in Québec Province. The work was carried out in six nursing homes (800 patients). Medication error data were collected from nursing staff through a voluntary reporting process before and after MDT was implemented. The errors were analysed using: totals errors; medication error type; severity and patient consequences. A statistical analysis verified whether there was a significant difference between the variables before and after introducing MDT. The results show that the MDT detected medication errors. The authors' analysis also indicates that errors are detected more rapidly resulting in less severe consequences for patients. MDT is a step towards safer and more efficient medication processes. Our findings should convince healthcare administrators to implement technology such as electronic prescriber or bar code medication administration systems to improve medication processes and to provide better healthcare to patients. Few studies have been carried out in long-term healthcare facilities such as nursing homes. The authors' study extends what is known about MDT's impact on medication errors in nursing homes.
The pattern of the discovery of medication errors in a tertiary hospital in Hong Kong.
Samaranayake, N R; Cheung, S T D; Chui, W C M; Cheung, B M Y
2013-06-01
The primary goal of reducing medication errors is to eliminate those that reach the patient. We aimed to study the pattern of interceptions to tackle medication errors along the medication use processes. Tertiary care hospital in Hong Kong. The 'Swiss Cheese Model' was used to explain the interceptions targeting medication error reporting over 5 years (2006-2010). Proportions of prescribing, dispensing and drug administration errors intercepted by pharmacists and nurses; proportions of prescribing, dispensing and drug administration errors that reached the patient. Our analysis included 1,268 in-patient medication errors, of which 53.4% were related to prescribing, 29.0% to administration and 17.6% to dispensing. 34.1% of all medication errors (4.9% prescribing, 26.8% drug administration and 2.4% dispensing) were not intercepted. Pharmacy staff intercepted 85.4% of the prescribing errors. Nurses detected 83.0% of dispensing and 5.0% of prescribing errors. However, 92.4% of all drug administration errors reached the patient. Having a preventive measure at each stage of the medication use process helps to prevent most errors. Most drug administration errors reach the patient as there is no defense against these. Therefore, more interventions to prevent drug administration errors are warranted.
Mostafaei, Davoud; Barati Marnani, Ahmad; Mosavi Esfahani, Haleh; Estebsari, Fatemeh; Shahzaidi, Shiva; Jamshidi, Ensiyeh; Aghamiri, Seyed Samad
2014-10-01
About one third of unwanted reported medication consequences are due to medication errors, resulting in one-fifth of hospital injuries. The aim of this study was determined formal and informal medication errors of nurses and the level of importance of factors in refusal to report medication errors among nurses. The cross-sectional study was done on the nursing staff of Shohada Tajrish Hospital, Tehran, Iran in 2012. The data was gathered through a questionnaire, made by the researchers. The questionnaires' face and content validity was confirmed by experts and for measuring its reliability test-retest was used. The data was analyzed by descriptive statistics. We used SPSS for related statistical analyses. The most important factors in refusal to report medication errors respectively were: lack of medication error recording and reporting system in the hospital (3.3%), non-significant error reporting to hospital authorities and lack of appropriate feedback (3.1%), and lack of a clear definition for a medication error (3%). There were both formal and informal reporting of medication errors in this study. Factors pertaining to management in hospitals as well as the fear of the consequences of reporting are two broad fields among the factors that make nurses not report their medication errors. In this regard, providing enough education to nurses, boosting the job security for nurses, management support and revising related processes and definitions are some factors that can help decreasing medication errors and increasing their report in case of occurrence.
Schmidt, Taly Gilat; Wang, Adam S; Coradi, Thomas; Haas, Benjamin; Star-Lack, Josh
2016-10-01
The overall goal of this work is to develop a rapid, accurate, and automated software tool to estimate patient-specific organ doses from computed tomography (CT) scans using simulations to generate dose maps combined with automated segmentation algorithms. This work quantified the accuracy of organ dose estimates obtained by an automated segmentation algorithm. We hypothesized that the autosegmentation algorithm is sufficiently accurate to provide organ dose estimates, since small errors delineating organ boundaries will have minimal effect when computing mean organ dose. A leave-one-out validation study of the automated algorithm was performed with 20 head-neck CT scans expertly segmented into nine regions. Mean organ doses of the automatically and expertly segmented regions were computed from Monte Carlo-generated dose maps and compared. The automated segmentation algorithm estimated the mean organ dose to be within 10% of the expert segmentation for regions other than the spinal canal, with the median error for each organ region below 2%. In the spinal canal region, the median error was [Formula: see text], with a maximum absolute error of 28% for the single-atlas approach and 11% for the multiatlas approach. The results demonstrate that the automated segmentation algorithm can provide accurate organ dose estimates despite some segmentation errors.
Schmidt, Taly Gilat; Wang, Adam S.; Coradi, Thomas; Haas, Benjamin; Star-Lack, Josh
2016-01-01
Abstract. The overall goal of this work is to develop a rapid, accurate, and automated software tool to estimate patient-specific organ doses from computed tomography (CT) scans using simulations to generate dose maps combined with automated segmentation algorithms. This work quantified the accuracy of organ dose estimates obtained by an automated segmentation algorithm. We hypothesized that the autosegmentation algorithm is sufficiently accurate to provide organ dose estimates, since small errors delineating organ boundaries will have minimal effect when computing mean organ dose. A leave-one-out validation study of the automated algorithm was performed with 20 head-neck CT scans expertly segmented into nine regions. Mean organ doses of the automatically and expertly segmented regions were computed from Monte Carlo-generated dose maps and compared. The automated segmentation algorithm estimated the mean organ dose to be within 10% of the expert segmentation for regions other than the spinal canal, with the median error for each organ region below 2%. In the spinal canal region, the median error was −7%, with a maximum absolute error of 28% for the single-atlas approach and 11% for the multiatlas approach. The results demonstrate that the automated segmentation algorithm can provide accurate organ dose estimates despite some segmentation errors. PMID:27921070
A cognitive taxonomy of medical errors.
Zhang, Jiajie; Patel, Vimla L; Johnson, Todd R; Shortliffe, Edward H
2004-06-01
Propose a cognitive taxonomy of medical errors at the level of individuals and their interactions with technology. Use cognitive theories of human error and human action to develop the theoretical foundations of the taxonomy, develop the structure of the taxonomy, populate the taxonomy with examples of medical error cases, identify cognitive mechanisms for each category of medical error under the taxonomy, and apply the taxonomy to practical problems. Four criteria were used to evaluate the cognitive taxonomy. The taxonomy should be able (1) to categorize major types of errors at the individual level along cognitive dimensions, (2) to associate each type of error with a specific underlying cognitive mechanism, (3) to describe how and explain why a specific error occurs, and (4) to generate intervention strategies for each type of error. The proposed cognitive taxonomy largely satisfies the four criteria at a theoretical and conceptual level. Theoretically, the proposed cognitive taxonomy provides a method to systematically categorize medical errors at the individual level along cognitive dimensions, leads to a better understanding of the underlying cognitive mechanisms of medical errors, and provides a framework that can guide future studies on medical errors. Practically, it provides guidelines for the development of cognitive interventions to decrease medical errors and foundation for the development of medical error reporting system that not only categorizes errors but also identifies problems and helps to generate solutions. To validate this model empirically, we will next be performing systematic experimental studies.
Clinical review: Medication errors in critical care
Moyen, Eric; Camiré, Eric; Stelfox, Henry Thomas
2008-01-01
Medication errors in critical care are frequent, serious, and predictable. Critically ill patients are prescribed twice as many medications as patients outside of the intensive care unit (ICU) and nearly all will suffer a potentially life-threatening error at some point during their stay. The aim of this article is to provide a basic review of medication errors in the ICU, identify risk factors for medication errors, and suggest strategies to prevent errors and manage their consequences. PMID:18373883
Sam, Aaseer Thamby; Lian Jessica, Looi Li; Parasuraman, Subramani
2015-01-01
Objectives: To retrospectively determine the extent and types of adverse drug events (ADEs) from the patient cases sheets and identify the contributing factors of medication errors. To assess causality and severity using the World Health Organization (WHO) probability scale and Hartwig's scale, respectively. Methods: Hundred patient case sheets were randomly selected, modified version of the Institute for Healthcare Improvement (IHI) Global Trigger Tool was utilized to identify the ADEs; causality and severity were calculated utilizing the WHO probability scale and Hartwig's severity assessment scale, respectively. Results: In total, 153 adverse events (AEs) were identified using the IHI Global Trigger Tool. Majority of the AEs are due to medication errors (46.41%) followed by 60 adverse drug reactions (ADRs), 15 therapeutic failure incidents, and 7 over-dose cases. Out of the 153 AEs, 60 are due to ADRs such as rashes, nausea, and vomiting. Therapeutic failure contributes 9.80% of the AEs, while overdose contributes to 4.58% of the total 153 AEs. Using the trigger tools, we were able to detect 45 positive triggers in 36 patient records. Among it, 19 AEs were identified in 15 patient records. The percentage of AE/100 patients is 17%. The average ADEs/1000 doses is 2.03% (calculated). Conclusion: The IHI Global Trigger Tool is an effective method to aid provisionally-registered pharmacists to identify ADEs quicker. PMID:25767366
McKaig, Donald; Collins, Christine; Elsaid, Khaled A
2014-09-01
A study was conducted to evaluate the impact of a reengineered approach to electronic error reporting at a 719-bed multidisciplinary urban medical center. The main outcome of interest was the monthly reported medication errors during the preimplementation (20 months) and postimplementation (26 months) phases. An interrupted time series analysis was used to describe baseline errors, immediate change following implementation of the current electronic error-reporting system (e-ERS), and trend of error reporting during postimplementation. Errors were categorized according to severity using the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP) Medication Error Index classifications. Reported errors were further analyzed by reporter and error site. During preimplementation, the monthly reported errors mean was 40.0 (95% confidence interval [CI]: 36.3-43.7). Immediately following e-ERS implementation, monthly reported errors significantly increased by 19.4 errors (95% CI: 8.4-30.5). The change in slope of reported errors trend was estimated at 0.76 (95% CI: 0.07-1.22). Near misses and no-patient-harm errors accounted for 90% of all errors, while errors that caused increased patient monitoring or temporary harm accounted for 9% and 1%, respectively. Nurses were the most frequent reporters, while physicians were more likely to report high-severity errors. Medical care units accounted for approximately half of all reported errors. Following the intervention, there was a significant increase in reporting of prevented errors and errors that reached the patient with no resultant harm. This improvement in reporting was sustained for 26 months and has contributed to designing and implementing quality improvement initiatives to enhance the safety of the medication use process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bender, Edward T.; Hardcastle, Nicholas; Tome, Wolfgang A.
2012-01-15
Purpose: Deformable image registration (DIR) is necessary for accurate dose accumulation between multiple radiotherapy image sets. DIR algorithms can suffer from inverse and transitivity inconsistencies. When using deformation vector fields (DVFs) that exhibit inverse-inconsistency and are nontransitive, dose accumulation on a given image set via different image pathways will lead to different accumulated doses. The purpose of this study was to investigate the dosimetric effect of and propose a postprocessing solution to reduce inverse consistency and transitivity errors. Methods: Four MVCT images and four phases of a lung 4DCT, each with an associated calculated dose, were selected for analysis. DVFsmore » between all four images in each data set were created using the Fast Symmetric Demons algorithm. Dose was accumulated on the fourth image in each set using DIR via two different image pathways. The two accumulated doses on the fourth image were compared. The inverse consistency and transitivity errors in the DVFs were then reduced. The dose accumulation was repeated using the processed DVFs, the results of which were compared with the accumulated dose from the original DVFs. To evaluate the influence of the postprocessing technique on DVF accuracy, the original and processed DVF accuracy was evaluated on the lung 4DCT data on which anatomical landmarks had been identified by an expert. Results: Dose accumulation to the same image via different image pathways resulted in two different accumulated dose results. After the inverse consistency errors were reduced, the difference between the accumulated doses diminished. The difference was further reduced after reducing the transitivity errors. The postprocessing technique had minimal effect on the accuracy of the DVF for the lung 4DCT images. Conclusions: This study shows that inverse consistency and transitivity errors in DIR have a significant dosimetric effect in dose accumulation; Depending on the image pathway taken to accumulate the dose, different results may be obtained. A postprocessing technique that reduces inverse consistency and transitivity error is presented, which allows for consistent dose accumulation regardless of the image pathway followed.« less
Nazione, Samantha; Pace, Kristin
2015-01-01
Medical malpractice lawsuits are a growing problem in the United States, and there is much controversy regarding how to best address this problem. The medical error disclosure framework suggests that apologizing, expressing empathy, engaging in corrective action, and offering compensation after a medical error may improve the provider-patient relationship and ultimately help reduce the number of medical malpractice lawsuits patients bring to medical providers. This study provides an experimental examination of the medical error disclosure framework and its effect on amount of money requested in a lawsuit, negative intentions, attitudes, and anger toward the provider after a medical error. Results suggest empathy may play a large role in providing positive outcomes after a medical error.
Drach-Zahavy, A; Somech, A; Admi, H; Peterfreund, I; Peker, H; Priente, O
2014-03-01
Attention in the ward should shift from preventing medication administration errors to managing them. Nevertheless, little is known in regard with the practices nursing wards apply to learn from medication administration errors as a means of limiting them. To test the effectiveness of four types of learning practices, namely, non-integrated, integrated, supervisory and patchy learning practices in limiting medication administration errors. Data were collected from a convenient sample of 4 hospitals in Israel by multiple methods (observations and self-report questionnaires) at two time points. The sample included 76 wards (360 nurses). Medication administration error was defined as any deviation from prescribed medication processes and measured by a validated structured observation sheet. Wards' use of medication administration technologies, location of the medication station, and workload were observed; learning practices and demographics were measured by validated questionnaires. Results of the mixed linear model analysis indicated that the use of technology and quiet location of the medication cabinet were significantly associated with reduced medication administration errors (estimate=.03, p<.05 and estimate=-.17, p<.01 correspondingly), while workload was significantly linked to inflated medication administration errors (estimate=.04, p<.05). Of the learning practices, supervisory learning was the only practice significantly linked to reduced medication administration errors (estimate=-.04, p<.05). Integrated and patchy learning were significantly linked to higher levels of medication administration errors (estimate=-.03, p<.05 and estimate=-.04, p<.01 correspondingly). Non-integrated learning was not associated with it (p>.05). How wards manage errors might have implications for medication administration errors beyond the effects of typical individual, organizational and technology risk factors. Head nurse can facilitate learning from errors by "management by walking around" and monitoring nurses' medication administration behaviors. Copyright © 2013 Elsevier Ltd. All rights reserved.
A multi-GPU real-time dose simulation software framework for lung radiotherapy.
Santhanam, A P; Min, Y; Neelakkantan, H; Papp, N; Meeks, S L; Kupelian, P A
2012-09-01
Medical simulation frameworks facilitate both the preoperative and postoperative analysis of the patient's pathophysical condition. Of particular importance is the simulation of radiation dose delivery for real-time radiotherapy monitoring and retrospective analyses of the patient's treatment. In this paper, a software framework tailored for the development of simulation-based real-time radiation dose monitoring medical applications is discussed. A multi-GPU-based computational framework coupled with inter-process communication methods is introduced for simulating the radiation dose delivery on a deformable 3D volumetric lung model and its real-time visualization. The model deformation and the corresponding dose calculation are allocated among the GPUs in a task-specific manner and is performed in a pipelined manner. Radiation dose calculations are computed on two different GPU hardware architectures. The integration of this computational framework with a front-end software layer and back-end patient database repository is also discussed. Real-time simulation of the dose delivered is achieved at once every 120 ms using the proposed framework. With a linear increase in the number of GPU cores, the computational time of the simulation was linearly decreased. The inter-process communication time also improved with an increase in the hardware memory. Variations in the delivered dose and computational speedup for variations in the data dimensions are investigated using D70 and D90 as well as gEUD as metrics for a set of 14 patients. Computational speed-up increased with an increase in the beam dimensions when compared with a CPU-based commercial software while the error in the dose calculation was <1%. Our analyses show that the framework applied to deformable lung model-based radiotherapy is an effective tool for performing both real-time and retrospective analyses.
Pegler, Joe; Lehane, Elaine; Livingstone, Vicki; McCarthy, Nora; Sahm, Laura J.; Tabirca, Sabin; O’Driscoll, Aoife; Corrigan, Mark
2016-01-01
Background Patient safety requires optimal management of medications. Electronic systems are encouraged to reduce medication errors. Near field communications (NFC) is an emerging technology that may be used to develop novel medication management systems. Methods An NFC-based system was designed to facilitate prescribing, administration and review of medications commonly used on surgical wards. Final year medical, nursing, and pharmacy students were recruited to test the electronic system in a cross-over observational setting on a simulated ward. Medication errors were compared against errors recorded using a paper-based system. Results A significant difference in the commission of medication errors was seen when NFC and paper-based medication systems were compared. Paper use resulted in a mean of 4.09 errors per prescribing round while NFC prescribing resulted in a mean of 0.22 errors per simulated prescribing round (P=0.000). Likewise, medication administration errors were reduced from a mean of 2.30 per drug round with a Paper system to a mean of 0.80 errors per round using NFC (P<0.015). A mean satisfaction score of 2.30 was reported by users, (rated on seven-point scale with 1 denoting total satisfaction with system use and 7 denoting total dissatisfaction). Conclusions An NFC based medication system may be used to effectively reduce medication errors in a simulated ward environment. PMID:28293602
O'Connell, Emer; Pegler, Joe; Lehane, Elaine; Livingstone, Vicki; McCarthy, Nora; Sahm, Laura J; Tabirca, Sabin; O'Driscoll, Aoife; Corrigan, Mark
2016-01-01
Patient safety requires optimal management of medications. Electronic systems are encouraged to reduce medication errors. Near field communications (NFC) is an emerging technology that may be used to develop novel medication management systems. An NFC-based system was designed to facilitate prescribing, administration and review of medications commonly used on surgical wards. Final year medical, nursing, and pharmacy students were recruited to test the electronic system in a cross-over observational setting on a simulated ward. Medication errors were compared against errors recorded using a paper-based system. A significant difference in the commission of medication errors was seen when NFC and paper-based medication systems were compared. Paper use resulted in a mean of 4.09 errors per prescribing round while NFC prescribing resulted in a mean of 0.22 errors per simulated prescribing round (P=0.000). Likewise, medication administration errors were reduced from a mean of 2.30 per drug round with a Paper system to a mean of 0.80 errors per round using NFC (P<0.015). A mean satisfaction score of 2.30 was reported by users, (rated on seven-point scale with 1 denoting total satisfaction with system use and 7 denoting total dissatisfaction). An NFC based medication system may be used to effectively reduce medication errors in a simulated ward environment.
Komase, Yuko; Asako, Akimoto; Kobayashi, Akihiro; Sharma, Raj
2014-01-01
Background In patients receiving inhaled medication, dissatisfaction with and difficulty in using the inhaler can affect treatment adherence. The incidence of handling errors is typically higher in the elderly than in younger people. The aim of the study was to assess inhaler preference for and handling errors with the ELLIPTA® dry powder inhaler (DPI), (GSK), compared with the established BREEZHALER™, a single-dose capsule DPI (Novartis), in inhalation device-naïve Japanese volunteers aged ≥40 years. Methods In this open-label, nondrug interventional, crossover DPI preference study comparing the ELLIPTA DPI and BREEZHALER, 150 subjects were randomized to handle the ELLIPTA or BREEZHALER DPIs until the point of inhalation, without receiving verbal or demonstrative instruction (first attempt). Subjects then crossed over to the other inhaler. Preference was assessed using a self-completed questionnaire. Inhaler handling was assessed by a trained assessor using a checklist. Subjects did not inhale any medication in the study, so efficacy and safety were not measured. Results The ELLIPTA DPI was preferred to the BREEZHALER by 89% of subjects (odds ratio [OR] 70.14, 95% confidence interval [CI] 33.69–146.01; P-value not applicable for this inhaler) for ease of use, by 63% of subjects (OR 2.98, CI 1.87–4.77; P<0.0001) for ease of determining the number of doses remaining in the inhaler, by 91% for number of steps required, and by 93% for time needed for handling the inhaler. The BREEZHALER was preferred to the ELLIPTA DPI for comfort of the mouthpiece by 64% of subjects (OR 3.16, CI 1.97–5.06; P<0.0001). The incidence of handling errors (first attempt) was 11% with ELLIPTA and 68% with BREEZHALER; differences in incidence were generally similar when analyzed by age (< or ≥65 years) or sex. Conclusion These data, obtained in an inhalation device-naïve population, suggest that the ELLIPTA DPI is preferred to an established alternative based on its ease-of-use features and is associated with fewer handling errors. PMID:25525354
Bifftu, Berhanu Boru; Dachew, Berihun Assefa; Tiruneh, Bewket Tadesse; Beshah, Debrework Tesgera
2016-01-01
Medication administration is the final step/phase of medication process in which its error directly affects the patient health. Due to the central role of nurses in medication administration, whether they are the source of an error, a contributor, or an observer they have the professional, legal and ethical responsibility to recognize and report. The aim of this study was to assess the prevalence of medication administration error reporting and associated factors among nurses working at The University of Gondar Referral Hospital, Northwest Ethiopia. Institution based quantitative cross - sectional study was conducted among 282 Nurses. Data were collected using semi-structured, self-administered questionnaire of the Medication Administration Errors Reporting (MAERs). Binary logistic regression with 95 % confidence interval was used to identify factors associated with medication administration errors reporting. The estimated medication administration error reporting was found to be 29.1 %. The perceived rates of medication administration errors reporting for non-intravenous related medications were ranged from 16.8 to 28.6 % and for intravenous-related from 20.6 to 33.4 %. Education status (AOR =1.38, 95 % CI: 4.009, 11.128), disagreement over time - error definition (AOR = 0.44, 95 % CI: 0.468, 0.990), administrative reason (AOR = 0.35, 95 % CI: 0.168, 0.710) and fear (AOR = 0.39, 95 % CI: 0.257, 0.838) were factors statistically significant for the refusal of reporting medication administration errors at p-value <0.05. In this study, less than one third of the study participants reported medication administration errors. Educational status, disagreement over time - error definition, administrative reason and fear were factors statistically significant for the refusal of errors reporting at p-value <0.05. Therefore, the results of this study suggest strategies that enhance the cultures of error reporting such as providing a clear definition of reportable errors and strengthen the educational status of nurses by the health care organization.
Automatic system testing of a decision support system for insulin dosing using Google Android.
Spat, Stephan; Höll, Bernhard; Petritsch, Georg; Schaupp, Lukas; Beck, Peter; Pieber, Thomas R
2013-01-01
Hyperglycaemia in hospitalized patients is a common and costly health care problem. The GlucoTab system is a mobile workflow and decision support system, aiming to facilitate efficient and safe glycemic control of non-critically ill patients. Being a medical device, the GlucoTab requires extensive and reproducible testing. A framework for high-volume, reproducible and automated system testing of the GlucoTab system was set up applying several Open Source tools for test automation and system time handling. The REACTION insulin titration protocol was investigated in a paper-based clinical trial (PBCT). In order to validate the GlucoTab system, data from this trial was used for simulation and system tests. In total, 1190 decision support action points were identified and simulated. Four data points (0.3%) resulted in a GlucoTab system error caused by a defective implementation. In 144 data points (12.1%), calculation errors of physicians and nurses in the PBCT were detected. The test framework was able to verify manual calculation of insulin doses and detect relatively many user errors and workflow anomalies in the PBCT data. This shows the high potential of the electronic decision support application to improve safety of implementation of an insulin titration protocol and workflow management system in clinical wards.
Implementation of a Lateral TBI protocol in a Mexican Cancer Center
NASA Astrophysics Data System (ADS)
Mesa, Francisco; Esquivel, Carlos; Eng, Tony; Papanikolaou, Niko; Sosa, Modesto A.
2008-08-01
The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validated for application at a cancer care center in United States. This protocol fundamentally focuses on patient care, avoiding instability and discomfort that may be encountered by other treatment regimes. In vivo dose verification with TLD-100 chips for each anatomical region of interest was utilized. TLD-100 chips were calibrated using a 6 MV photon beam for 10-120 cGy. Experimental results show TLD measurements with an error less than 1%. Standard deviations for calculated and measured doses for seven patients have been obtained. Data gathered for different levels of compensation indicate that a 3% measured tolerance level is acceptable. TLD point-dose measurements have been used to verify the dose beyond partial transmission lung blocks. Dose measurements beyond the lung block showed variation about 50% respects to prescribe dose. Midplane doses to the other anatomical sites were less than 2.5% respect of the prescribed dose.
Medical error and related factors during internship and residency.
Ahmadipour, Habibeh; Nahid, Mortazavi
2015-01-01
It is difficult to determine the real incidence of medical errors due to the lack of a precise definition of errors, as well as the failure to report them under certain circumstances. We carried out a cross- sectional study in Kerman University of Medical Sciences, Iran in 2013. The participants were selected through the census method. The data were collected using a self-administered questionnaire, which consisted of questions on the participants' demographic data and questions on the medical errors committed. The data were analysed by SPSS 19. It was found that 270 participants had committed medical errors. There was no significant difference in the frequency of errors committed by interns and residents. In the case of residents, the most common error was misdiagnosis and in that of interns, errors related to history-taking and physical examination. Considering that medical errors are common in the clinical setting, the education system should train interns and residents to prevent the occurrence of errors. In addition, the system should develop a positive attitude among them so that they can deal better with medical errors.
Jember, Abebaw; Hailu, Mignote; Messele, Anteneh; Demeke, Tesfaye; Hassen, Mohammed
2018-01-01
A medication error (ME) is any preventable event that may cause or lead to inappropriate medication use or patient harm. Voluntary reporting has a principal role in appreciating the extent and impact of medication errors. Thus, exploration of the proportion of medication error reporting and associated factors among nurses is important to inform service providers and program implementers so as to improve the quality of the healthcare services. Institution based quantitative cross-sectional study was conducted among 397 nurses from March 6 to May 10, 2015. Stratified sampling followed by simple random sampling technique was used to select the study participants. The data were collected using structured self-administered questionnaire which was adopted from studies conducted in Australia and Jordan. A pilot study was carried out to validate the questionnaire before data collection for this study. Bivariate and multivariate logistic regression models were fitted to identify factors associated with the proportion of medication error reporting among nurses. An adjusted odds ratio with 95% confidence interval was computed to determine the level of significance. The proportion of medication error reporting among nurses was found to be 57.4%. Regression analysis showed that sex, marital status, having made a medication error and medication error experience were significantly associated with medication error reporting. The proportion of medication error reporting among nurses in this study was found to be higher than other studies.
Medication Safety Principles and Practice in CKD.
Whittaker, Chanel F; Miklich, Margaret A; Patel, Roshni S; Fink, Jeffrey C
2018-06-18
Ensuring patient safety is a priority of medical care because iatrogenic injury has been a primary concern. Medications are an important source of medical errors, and kidney disease is a thoroughfare of factors threatening safe administration of medicines. Principal among these is reduced kidney function because almost half of all medications used are eliminated via the kidney. Additionally, kidney patients often suffer from multimorbidity, including diabetes, hypertension, and heart failure, with a range of prescribers who often do not coordinate treatments. Patients with kidney disease are also susceptible to further kidney injury and metabolic derangements from medications, which can worsen the disease. In this review, we will present the key issues and threats to safe medication use in kidney disease, with a focus on predialysis CKD, as the scope of medication safety in ESKD and transplantation are unique and deserve their own consideration. We discuss drugs that need to be avoided or dose modified, and review the complications of a range of medications routinely administered in CKD, as these also call for cautious use. Copyright © 2018 by the American Society of Nephrology.
Phipps, Denham L; Tam, W Vanessa; Ashcroft, Darren M
2017-03-01
To explore the combined use of a critical incident database and work domain analysis to understand patient safety issues in a health-care setting. A retrospective review was conducted of incidents reported to the UK National Reporting and Learning System (NRLS) that involved community pharmacy between April 2005 and August 2010. A work domain analysis of community pharmacy was constructed using observational data from 5 community pharmacies, technical documentation, and a focus group with 6 pharmacists. Reports from the NRLS were mapped onto the model generated by the work domain analysis. Approximately 14,709 incident reports meeting the selection criteria were retrieved from the NRLS. Descriptive statistical analysis of these reports found that almost all of the incidents involved medication and that the most frequently occurring error types were dose/strength errors, incorrect medication, and incorrect formulation. The work domain analysis identified 4 overall purposes for community pharmacy: business viability, health promotion and clinical services, provision of medication, and use of medication. These purposes were served by lower-order characteristics of the work system (such as the functions, processes and objects). The tasks most frequently implicated in the incident reports were those involving medication storage, assembly, or patient medication records. Combining the insights from different analytical methods improves understanding of patient safety problems. Incident reporting data can be used to identify general patterns, whereas the work domain analysis can generate information about the contextual factors that surround a critical task.
Medication administration errors in nursing homes using an automated medication dispensing system.
van den Bemt, Patricia M L A; Idzinga, Jetske C; Robertz, Hans; Kormelink, Dennis Groot; Pels, Neske
2009-01-01
OBJECTIVE To identify the frequency of medication administration errors as well as their potential risk factors in nursing homes using a distribution robot. DESIGN The study was a prospective, observational study conducted within three nursing homes in the Netherlands caring for 180 individuals. MEASUREMENTS Medication errors were measured using the disguised observation technique. Types of medication errors were described. The correlation between several potential risk factors and the occurrence of medication errors was studied to identify potential causes for the errors. RESULTS In total 2,025 medication administrations to 127 clients were observed. In these administrations 428 errors were observed (21.2%). The most frequently occurring types of errors were use of wrong administration techniques (especially incorrect crushing of medication and not supervising the intake of medication) and wrong time errors (administering the medication at least 1 h early or late).The potential risk factors female gender (odds ratio (OR) 1.39; 95% confidence interval (CI) 1.05-1.83), ATC medication class antibiotics (OR 11.11; 95% CI 2.66-46.50), medication crushed (OR 7.83; 95% CI 5.40-11.36), number of dosages/day/client (OR 1.03; 95% CI 1.01-1.05), nursing home 2 (OR 3.97; 95% CI 2.86-5.50), medication not supplied by distribution robot (OR 2.92; 95% CI 2.04-4.18), time classes "7-10 am" (OR 2.28; 95% CI 1.50-3.47) and "10 am-2 pm" (OR 1.96; 1.18-3.27) and day of the week "Wednesday" (OR 1.46; 95% CI 1.03-2.07) are associated with a higher risk of administration errors. CONCLUSIONS Medication administration in nursing homes is prone to many errors. This study indicates that the handling of the medication after removing it from the robot packaging may contribute to this high error frequency, which may be reduced by training of nurse attendants, by automated clinical decision support and by measures to reduce workload.
Interventions to reduce medication errors in neonatal care: a systematic review
Nguyen, Minh-Nha Rhylie; Mosel, Cassandra
2017-01-01
Background: Medication errors represent a significant but often preventable cause of morbidity and mortality in neonates. The objective of this systematic review was to determine the effectiveness of interventions to reduce neonatal medication errors. Methods: A systematic review was undertaken of all comparative and noncomparative studies published in any language, identified from searches of PubMed and EMBASE and reference-list checking. Eligible studies were those investigating the impact of any medication safety interventions aimed at reducing medication errors in neonates in the hospital setting. Results: A total of 102 studies were identified that met the inclusion criteria, including 86 comparative and 16 noncomparative studies. Medication safety interventions were classified into six themes: technology (n = 38; e.g. electronic prescribing), organizational (n = 16; e.g. guidelines, policies, and procedures), personnel (n = 13; e.g. staff education), pharmacy (n = 9; e.g. clinical pharmacy service), hazard and risk analysis (n = 8; e.g. error detection tools), and multifactorial (n = 18; e.g. any combination of previous interventions). Significant variability was evident across all included studies, with differences in intervention strategies, trial methods, types of medication errors evaluated, and how medication errors were identified and evaluated. Most studies demonstrated an appreciable risk of bias. The vast majority of studies (>90%) demonstrated a reduction in medication errors. A similar median reduction of 50–70% in medication errors was evident across studies included within each of the identified themes, but findings varied considerably from a 16% increase in medication errors to a 100% reduction in medication errors. Conclusion: While neonatal medication errors can be reduced through multiple interventions aimed at improving the medication use process, no single intervention appeared clearly superior. Further research is required to evaluate the relative cost-effectiveness of the various medication safety interventions to facilitate decisions regarding uptake and implementation into clinical practice. PMID:29387337
Koppel, Ross; Wetterneck, Tosha; Telles, Joel Leon; Karsh, Ben-Tzion
2008-01-01
The authors develop a typology of clinicians' workarounds when using barcoded medication administration (BCMA) systems. Authors then identify the causes and possible consequences of each workaround. The BCMAs usually consist of handheld devices for scanning machine-readable barcodes on patients and medications. They also interface with electronic medication administration records. Ideally, BCMAs help confirm the five “rights” of medication administration: right patient, drug, dose, route, and time. While BCMAs are reported to reduce medication administration errors—the least likely medication error to be intercepted— these claims have not been clearly demonstrated. The authors studied BCMA use at five hospitals by: (1) observing and shadowing nurses using BCMAs at two hospitals, (2) interviewing staff and hospital leaders at five hospitals, (3) participating in BCMA staff meetings, (4) participating in one hospital's failure-mode-and-effects analyses, (5) analyzing BCMA override log data. The authors identified 15 types of workarounds, including, for example, affixing patient identification barcodes to computer carts, scanners, doorjambs, or nurses' belt rings; carrying several patients' prescanned medications on carts. The authors identified 31 types of causes of workarounds, such as unreadable medication barcodes (crinkled, smudged, torn, missing, covered by another label); malfunctioning scanners; unreadable or missing patient identification wristbands (chewed, soaked, missing); nonbarcoded medications; failing batteries; uncertain wireless connectivity; emergencies. The authors found nurses overrode BCMA alerts for 4.2% of patients charted and for 10.3% of medications charted. Possible consequences of the workarounds include wrong administration of medications, wrong doses, wrong times, and wrong formulations. Shortcomings in BCMAs' design, implementation, and workflow integration encourage workarounds. Integrating BCMAs within real-world clinical workflows requires attention to in situ use to ensure safety features' correct use. PMID:18436903
NASA Astrophysics Data System (ADS)
Gilat-Schmidt, Taly; Wang, Adam; Coradi, Thomas; Haas, Benjamin; Star-Lack, Josh
2016-03-01
The overall goal of this work is to develop a rapid, accurate and fully automated software tool to estimate patient-specific organ doses from computed tomography (CT) scans using a deterministic Boltzmann Transport Equation solver and automated CT segmentation algorithms. This work quantified the accuracy of organ dose estimates obtained by an automated segmentation algorithm. The investigated algorithm uses a combination of feature-based and atlas-based methods. A multiatlas approach was also investigated. We hypothesize that the auto-segmentation algorithm is sufficiently accurate to provide organ dose estimates since random errors at the organ boundaries will average out when computing the total organ dose. To test this hypothesis, twenty head-neck CT scans were expertly segmented into nine regions. A leave-one-out validation study was performed, where every case was automatically segmented with each of the remaining cases used as the expert atlas, resulting in nineteen automated segmentations for each of the twenty datasets. The segmented regions were applied to gold-standard Monte Carlo dose maps to estimate mean and peak organ doses. The results demonstrated that the fully automated segmentation algorithm estimated the mean organ dose to within 10% of the expert segmentation for regions other than the spinal canal, with median error for each organ region below 2%. In the spinal canal region, the median error was 7% across all data sets and atlases, with a maximum error of 20%. The error in peak organ dose was below 10% for all regions, with a median error below 4% for all organ regions. The multiple-case atlas reduced the variation in the dose estimates and additional improvements may be possible with more robust multi-atlas approaches. Overall, the results support potential feasibility of an automated segmentation algorithm to provide accurate organ dose estimates.
Quantification of residual dose estimation error on log file-based patient dose calculation.
Katsuta, Yoshiyuki; Kadoya, Noriyuki; Fujita, Yukio; Shimizu, Eiji; Matsunaga, Kenichi; Matsushita, Haruo; Majima, Kazuhiro; Jingu, Keiichi
2016-05-01
The log file-based patient dose estimation includes a residual dose estimation error caused by leaf miscalibration, which cannot be reflected on the estimated dose. The purpose of this study is to determine this residual dose estimation error. Modified log files for seven head-and-neck and prostate volumetric modulated arc therapy (VMAT) plans simulating leaf miscalibration were generated by shifting both leaf banks (systematic leaf gap errors: ±2.0, ±1.0, and ±0.5mm in opposite directions and systematic leaf shifts: ±1.0mm in the same direction) using MATLAB-based (MathWorks, Natick, MA) in-house software. The generated modified and non-modified log files were imported back into the treatment planning system and recalculated. Subsequently, the generalized equivalent uniform dose (gEUD) was quantified for the definition of the planning target volume (PTV) and organs at risks. For MLC leaves calibrated within ±0.5mm, the quantified residual dose estimation errors that obtained from the slope of the linear regression of gEUD changes between non- and modified log file doses per leaf gap are in head-and-neck plans 1.32±0.27% and 0.82±0.17Gy for PTV and spinal cord, respectively, and in prostate plans 1.22±0.36%, 0.95±0.14Gy, and 0.45±0.08Gy for PTV, rectum, and bladder, respectively. In this work, we determine the residual dose estimation errors for VMAT delivery using the log file-based patient dose calculation according to the MLC calibration accuracy. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Westbrook, Johanna I.; Li, Ling; Lehnbom, Elin C.; Baysari, Melissa T.; Braithwaite, Jeffrey; Burke, Rosemary; Conn, Chris; Day, Richard O.
2015-01-01
Objectives To (i) compare medication errors identified at audit and observation with medication incident reports; (ii) identify differences between two hospitals in incident report frequency and medication error rates; (iii) identify prescribing error detection rates by staff. Design Audit of 3291patient records at two hospitals to identify prescribing errors and evidence of their detection by staff. Medication administration errors were identified from a direct observational study of 180 nurses administering 7451 medications. Severity of errors was classified. Those likely to lead to patient harm were categorized as ‘clinically important’. Setting Two major academic teaching hospitals in Sydney, Australia. Main Outcome Measures Rates of medication errors identified from audit and from direct observation were compared with reported medication incident reports. Results A total of 12 567 prescribing errors were identified at audit. Of these 1.2/1000 errors (95% CI: 0.6–1.8) had incident reports. Clinically important prescribing errors (n = 539) were detected by staff at a rate of 218.9/1000 (95% CI: 184.0–253.8), but only 13.0/1000 (95% CI: 3.4–22.5) were reported. 78.1% (n = 421) of clinically important prescribing errors were not detected. A total of 2043 drug administrations (27.4%; 95% CI: 26.4–28.4%) contained ≥1 errors; none had an incident report. Hospital A had a higher frequency of incident reports than Hospital B, but a lower rate of errors at audit. Conclusions Prescribing errors with the potential to cause harm frequently go undetected. Reported incidents do not reflect the profile of medication errors which occur in hospitals or the underlying rates. This demonstrates the inaccuracy of using incident frequency to compare patient risk or quality performance within or across hospitals. New approaches including data mining of electronic clinical information systems are required to support more effective medication error detection and mitigation. PMID:25583702
Reflection of medical error highlighted on media in Turkey: A retrospective study
Isik, Oguz; Bayin, Gamze; Ugurluoglu, Ozgur
2016-01-01
Objective: This study was performed with the aim of identifying how news on medical errors have be transmitted, and how the types, reasons, and conclusions of medical errors have been reflected to by the media in Turkey. Methods: A content analysis method was used in the study, and in this context, the data for the study was acquired by scanning five newspapers with the top editions on the national basis between the years 2012 and 2015 for the news about medical errors. Some specific selection criteria was used for the scanning of resulted news, and 116 news items acquired as a result of all the eliminations. Results: According to the results of the study; the vast majority of medical errors (40.5%) transmitted by the news resulted from the negligence of the medical staff. The medical errors were caused by physicians in the ratio of 74.1%, they most commonly occurred in state hospitals (31.9%). Another important result of the research was that medical errors resulted in either patient death to a large extent (51.7%), or permanent damage and disability to patients (25.0%). Conclusion: The news concerning medical errors provided information about the types, causes, and the results of these medical errors. It also reflected the media point of view on the issue. The examination of the content of the medical errors reported by the media were important which calls for appropriate interventions to avoid and minimize the occurrence of medical errors by improving the healthcare delivery system. PMID:27882026
Cao, Hui; Stetson, Peter; Hripcsak, George
2003-01-01
Many types of medical errors occur in and outside of hospitals, some of which have very serious consequences and increase cost. Identifying errors is a critical step for managing and preventing them. In this study, we assessed the explicit reporting of medical errors in the electronic record. We used five search terms "mistake," "error," "incorrect," "inadvertent," and "iatrogenic" to survey several sets of narrative reports including discharge summaries, sign-out notes, and outpatient notes from 1991 to 2000. We manually reviewed all the positive cases and identified them based on the reporting of physicians. We identified 222 explicitly reported medical errors. The positive predictive value varied with different keywords. In general, the positive predictive value for each keyword was low, ranging from 3.4 to 24.4%. Therapeutic-related errors were the most common reported errors and these reported therapeutic-related errors were mainly medication errors. Keyword searches combined with manual review indicated some medical errors that were reported in medical records. It had a low sensitivity and a moderate positive predictive value, which varied by search term. Physicians were most likely to record errors in the Hospital Course and History of Present Illness sections of discharge summaries. The reported errors in medical records covered a broad range and were related to several types of care providers as well as non-health care professionals.
Fanning, Laura; Jones, Nick; Manias, Elizabeth
2016-04-01
The implementation of automated dispensing cabinets (ADCs) in healthcare facilities appears to be increasing, in particular within Australian hospital emergency departments (EDs). While the investment in ADCs is on the increase, no studies have specifically investigated the impacts of ADCs on medication selection and preparation error rates in EDs. Our aim was to assess the impact of ADCs on medication selection and preparation error rates in an ED of a tertiary teaching hospital. Pre intervention and post intervention study involving direct observations of nurses completing medication selection and preparation activities before and after the implementation of ADCs in the original and new emergency departments within a 377-bed tertiary teaching hospital in Australia. Medication selection and preparation error rates were calculated and compared between these two periods. Secondary end points included the impact on medication error type and severity. A total of 2087 medication selection and preparations were observed among 808 patients pre and post intervention. Implementation of ADCs in the new ED resulted in a 64.7% (1.96% versus 0.69%, respectively, P = 0.017) reduction in medication selection and preparation errors. All medication error types were reduced in the post intervention study period. There was an insignificant impact on medication error severity as all errors detected were categorised as minor. The implementation of ADCs could reduce medication selection and preparation errors and improve medication safety in an ED setting. © 2015 John Wiley & Sons, Ltd.
Hatcher, Irene; Sullivan, Mark; Hutchinson, James; Thurman, Susan; Gaffney, F Andrew
2004-10-01
Improving medication safety at the point of care--particularly for high-risk drugs--is a major concern of nursing administrators. The medication errors most likely to cause harm are administration errors related to infusion of high-risk medications. An intravenous medication safety system is designed to prevent high-risk infusion medication errors and to capture continuous quality improvement data for best practice improvement. Initial testing with 50 systems in 2 units at Vanderbilt University Medical Center revealed that, even in the presence of a fully mature computerized prescriber order-entry system, the new safety system averted 99 potential infusion errors in 8 months.
Ziemann, Christian; Stille, Maik; Cremers, Florian; Buzug, Thorsten M; Rades, Dirk
2018-04-17
Metal artifacts caused by high-density implants lead to incorrectly reconstructed Hounsfield units in computed tomography images. This can result in a loss of accuracy in dose calculation in radiation therapy. This study investigates the potential of the metal artifact reduction algorithms, Augmented Likelihood Image Reconstruction and linear interpolation, in improving dose calculation in the presence of metal artifacts. In order to simulate a pelvis with a double-sided total endoprosthesis, a polymethylmethacrylate phantom was equipped with two steel bars. Artifacts were reduced by applying the Augmented Likelihood Image Reconstruction, a linear interpolation, and a manual correction approach. Using the treatment planning system Eclipse™, identical planning target volumes for an idealized prostate as well as structures for bladder and rectum were defined in corrected and noncorrected images. Volumetric modulated arc therapy plans have been created with double arc rotations with and without avoidance sectors that mask out the prosthesis. The irradiation plans were analyzed for variations in the dose distribution and their homogeneity. Dosimetric measurements were performed using isocentric positioned ionization chambers. Irradiation plans based on images containing artifacts lead to a dose error in the isocenter of up to 8.4%. Corrections with the Augmented Likelihood Image Reconstruction reduce this dose error to 2.7%, corrections with linear interpolation to 3.2%, and manual artifact correction to 4.1%. When applying artifact correction, the dose homogeneity was slightly improved for all investigated methods. Furthermore, the calculated mean doses are higher for rectum and bladder if avoidance sectors are applied. Streaking artifacts cause an imprecise dose calculation within irradiation plans. Using a metal artifact correction algorithm, the planning accuracy can be significantly improved. Best results were accomplished using the Augmented Likelihood Image Reconstruction algorithm. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
The Impact of Incident Disclosure Behaviors on Medical Malpractice Claims.
Giraldo, Priscila; Sato, Luke; Castells, Xavier
2017-06-30
To provide preliminary estimates of incident disclosure behaviors on medical malpractice claims. We conducted a descriptive analysis of data on medical malpractice claims obtained from the Controlled Risk Insurance Company and Risk Management Foundation of Harvard Medical Institutions (Cambridge, Massachusetts) between 2012 and 2013 (n = 434). The characteristics of disclosure and apology after medical errors were analyzed. Of 434 medical malpractice claims, 4.6% (n = 20) medical errors had been disclosed to the patient at the time of the error, and 5.9% (n = 26) had been followed by disclosure and apology. The highest number of disclosed injuries occurred in 2011 (23.9%; n = 11) and 2012 (34.8%; n = 16). There was no incremental increase during the financial years studied (2012-2013). The mean age of informed patients was 52.96 years, 58.7 % of the patients were female, and 52.2% were inpatients. Of the disclosed errors, 26.1% led to an adverse reaction, and 17.4% were fatal. The cause of disclosed medical error was improper surgical performance in 17.4% (95% confidence interval, 6.4-28.4). Disclosed medical errors were classified as medium severity in 67.4%. No apology statement was issued in 54.5% of medical errors classified as high severity. At the health-care centers studied, when a claim followed a medical error, providers infrequently disclosed medical errors or apologized to the patient or relatives. Most of the medical errors followed by disclosure and apology were classified as being of high and medium severity. No changes were detected in the volume of lawsuits over time.
Nurses' Responses and Reactions to an Emergent Pediatric Simulation Exercise.
Hoffman, Kenneth; von Sadovszky, Victoria
Pediatric nurses' responses and reactions in emergent simulations are understudied. Using authority gradient theory as a guide, the purpose of this study was to examine nurses' reactions during an emergency simulation exercise when directed to give an incorrect medication dose. Ten groups of noncritical care nurses were videotaped from the beginning of the simulation through debriefing. Although errors were made during the simulation event, all groups responded correctly during debriefing, indicating that authority gradient may play a role in clinical decision-making.
Samaranayake, N R; Cheung, S T D; Chui, W C M; Cheung, B M Y
2012-12-01
Healthcare technology is meant to reduce medication errors. The objective of this study was to assess unintended errors related to technologies in the medication use process. Medication incidents reported from 2006 to 2010 in a main tertiary care hospital were analysed by a pharmacist and technology-related errors were identified. Technology-related errors were further classified as socio-technical errors and device errors. This analysis was conducted using data from medication incident reports which may represent only a small proportion of medication errors that actually takes place in a hospital. Hence, interpretation of results must be tentative. 1538 medication incidents were reported. 17.1% of all incidents were technology-related, of which only 1.9% were device errors, whereas most were socio-technical errors (98.1%). Of these, 61.2% were linked to computerised prescription order entry, 23.2% to bar-coded patient identification labels, 7.2% to infusion pumps, 6.8% to computer-aided dispensing label generation and 1.5% to other technologies. The immediate causes for technology-related errors included, poor interface between user and computer (68.1%), improper procedures or rule violations (22.1%), poor interface between user and infusion pump (4.9%), technical defects (1.9%) and others (3.0%). In 11.4% of the technology-related incidents, the error was detected after the drug had been administered. A considerable proportion of all incidents were technology-related. Most errors were due to socio-technical issues. Unintended and unanticipated errors may happen when using technologies. Therefore, when using technologies, system improvement, awareness, training and monitoring are needed to minimise medication errors. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
The spectrum of medical errors: when patients sue
Kels, Barry D; Grant-Kels, Jane M
2012-01-01
Inarguably medical errors constitute a serious, dangerous, and expensive problem for the twenty-first-century US health care system. This review examines the incidence, nature, and complexity of alleged medical negligence and medical malpractice. The authors hope this will constitute a road map to medical providers so that they can better understand the present climate and hopefully avoid the “Scylla and Charybdis” of medical errors and medical malpractice. Despite some documented success in reducing medical errors, adverse events and medical errors continue to represent an indelible stain upon the practice, reputation, and success of the US health care industry. In that regard, what may be required to successfully attack the unacceptably high severity and volume of medical errors is a locally directed and organized initiative sponsored by individual health care organizations that is coordinated, supported, and guided by state and federal governmental and nongovernmental agencies. PMID:22924008
Hayashino, Yasuaki; Utsugi-Ozaki, Makiko; Feldman, Mitchell D.; Fukuhara, Shunichi
2012-01-01
The presence of hope has been found to influence an individual's ability to cope with stressful situations. The objective of this study is to evaluate the relationship between medical errors, hope and burnout among practicing physicians using validated metrics. Prospective cohort study was conducted among hospital based physicians practicing in Japan (N = 836). Measures included the validated Burnout Scale, self-assessment of medical errors and Herth Hope Index (HHI). The main outcome measure was the frequency of self-perceived medical errors, and Poisson regression analysis was used to evaluate the association between hope and medical error. A total of 361 errors were reported in 836 physician-years. We observed a significant association between hope and self-report of medical errors. Compared with the lowest tertile category of HHI, incidence rate ratios (IRRs) of self-perceived medical errors of physicians in the highest category were 0.44 (95%CI, 0.34 to 0.58) and 0.54 (95%CI, 0.42 to 0.70) respectively, for the 2nd and 3rd tertile. In stratified analysis by hope score, among physicians with a low hope score, those who experienced higher burnout reported higher incidence of errors; physicians with high hope scores did not report high incidences of errors, even if they experienced high burnout. Self-perceived medical errors showed a strong association with physicians' hope, and hope modified the association between physicians' burnout and self-perceived medical errors. PMID:22530055
Medical errors in primary care clinics – a cross sectional study
2012-01-01
Background Patient safety is vital in patient care. There is a lack of studies on medical errors in primary care settings. The aim of the study is to determine the extent of diagnostic inaccuracies and management errors in public funded primary care clinics. Methods This was a cross-sectional study conducted in twelve public funded primary care clinics in Malaysia. A total of 1753 medical records were randomly selected in 12 primary care clinics in 2007 and were reviewed by trained family physicians for diagnostic, management and documentation errors, potential errors causing serious harm and likelihood of preventability of such errors. Results The majority of patient encounters (81%) were with medical assistants. Diagnostic errors were present in 3.6% (95% CI: 2.2, 5.0) of medical records and management errors in 53.2% (95% CI: 46.3, 60.2). For management errors, medication errors were present in 41.1% (95% CI: 35.8, 46.4) of records, investigation errors in 21.7% (95% CI: 16.5, 26.8) and decision making errors in 14.5% (95% CI: 10.8, 18.2). A total of 39.9% (95% CI: 33.1, 46.7) of these errors had the potential to cause serious harm. Problems of documentation including illegible handwriting were found in 98.0% (95% CI: 97.0, 99.1) of records. Nearly all errors (93.5%) detected were considered preventable. Conclusions The occurrence of medical errors was high in primary care clinics particularly with documentation and medication errors. Nearly all were preventable. Remedial intervention addressing completeness of documentation and prescriptions are likely to yield reduction of errors. PMID:23267547
Markovic, Marija; Mathis, A Scott; Ghin, Hoytin Lee; Gardiner, Michelle; Fahim, Germin
2017-01-01
To compare the medication history error rate of the emergency department (ED) pharmacy technician with that of nursing staff and to describe the workflow environment. Fifty medication histories performed by an ED nurse followed by the pharmacy technician were evaluated for discrepancies (RN-PT group). A separate 50 medication histories performed by the pharmacy technician and observed with necessary intervention by the ED pharmacist were evaluated for discrepancies (PT-RPh group). Discrepancies were totaled and categorized by type of error and therapeutic category of the medication. The workflow description was obtained by observation and staff interview. A total of 474 medications in the RN-PT group and 521 in the PT-RPh group were evaluated. Nurses made at least one error in all 50 medication histories (100%), compared to 18 medication histories for the pharmacy technician (36%). In the RN-PT group, 408 medications had at least one error, corresponding to an accuracy rate of 14% for nurses. In the PT-RPh group, 30 medications had an error, corresponding to an accuracy rate of 94.4% for the pharmacy technician ( P < 0.0001). The most common error made by nurses was a missing medication (n = 109), while the most common error for the pharmacy technician was a wrong medication frequency (n = 19). The most common drug class with documented errors for ED nurses was cardiovascular medications (n = 100), while the pharmacy technician made the most errors in gastrointestinal medications (n = 11). Medication histories obtained by the pharmacy technician were significantly more accurate than those obtained by nurses in the emergency department.
Huynh, Chi; Wong, Ian C K; Correa-West, Jo; Terry, David; McCarthy, Suzanne
2017-04-01
Since the publication of To Err Is Human: Building a Safer Health System in 1999, there has been much research conducted into the epidemiology, nature and causes of medication errors in children, from prescribing and supply to administration. It is reassuring to see growing evidence of improving medication safety in children; however, based on media reports, it can be seen that serious and fatal medication errors still occur. This critical opinion article examines the problem of medication errors in children and provides recommendations for research, training of healthcare professionals and a culture shift towards dealing with medication errors. There are three factors that we need to consider to unravel what is missing and why fatal medication errors still occur. (1) Who is involved and affected by the medication error? (2) What factors hinder staff and organisations from learning from mistakes? Does the fear of litigation and criminal charges deter healthcare professionals from voluntarily reporting medication errors? (3) What are the educational needs required to prevent medication errors? It is important to educate future healthcare professionals about medication errors and human factors to prevent these from happening. Further research is required to apply aviation's 'black box' principles in healthcare to record and learn from near misses and errors to prevent future events. There is an urgent need for the black box investigations to be published and made public for the benefit of other organisations that may have similar potential risks for adverse events. International sharing of investigations and learning is also needed.
Balasuriya, Lilanthi; Vyles, David; Bakerman, Paul; Holton, Vanessa; Vaidya, Vinay; Garcia-Filion, Pamela; Westdorp, Joan; Sanchez, Christine; Kurz, Rhonda
2017-09-01
An enhanced dose range checking (DRC) system was developed to evaluate prescription error rates in the pediatric intensive care unit and the pediatric cardiovascular intensive care unit. An enhanced DRC system incorporating "soft" and "hard" alerts was designed and implemented. Practitioner responses to alerts for patients admitted to the pediatric intensive care unit and the pediatric cardiovascular intensive care unit were retrospectively reviewed. Alert rates increased from 0.3% to 3.4% after "go-live" (P < 0.001). Before go-live, all alerts were soft alerts. In the period after go-live, 68% of alerts were soft alerts and 32% were hard alerts. Before go-live, providers reduced doses only 1 time for every 10 dose alerts. After implementation of the enhanced computerized physician order entry system, the practitioners responded to soft alerts by reducing doses to more appropriate levels in 24.7% of orders (70/283), compared with 10% (3/30) before go-live (P = 0.0701). The practitioners deleted orders in 9.5% of cases (27/283) after implementation of the enhanced DRC system, as compared with no cancelled orders before go-live (P = 0.0774). Medication orders that triggered a soft alert were submitted unmodified in 65.7% (186/283) as compared with 90% (27/30) of orders before go-live (P = 0.0067). After go-live, 28.7% of hard alerts resulted in a reduced dose, 64% resulted in a cancelled order, and 7.4% were submitted as written. Before go-live, alerts were often clinically irrelevant. After go-live, there was a statistically significant decrease in orders that were submitted unmodified and an increase in the number of orders that were reduced or cancelled.
Impact of spot charge inaccuracies in IMPT treatments.
Kraan, Aafke C; Depauw, Nicolas; Clasie, Ben; Giunta, Marina; Madden, Tom; Kooy, Hanne M
2017-08-01
Spot charge is one parameter of pencil-beam scanning dose delivery system whose accuracy is typically high but whose required value has not been investigated. In this work we quantify the dose impact of spot charge inaccuracies on the dose distribution in patients. Knowing the effect of charge errors is relevant for conventional proton machines, as well as for new generation proton machines, where ensuring accurate charge may be challenging. Through perturbation of spot charge in treatment plans for seven patients and a phantom, we evaluated the dose impact of absolute (up to 5× 10 6 protons) and relative (up to 30%) charge errors. We investigated the dependence on beam width by studying scenarios with small, medium and large beam sizes. Treatment plan statistics included the Γ passing rate, dose-volume-histograms and dose differences. The allowable absolute charge error for small spot plans was about 2× 10 6 protons. Larger limits would be allowed if larger spots were used. For relative errors, the maximum allowable error size for small, medium and large spots was about 13%, 8% and 6% for small, medium and large spots, respectively. Dose distributions turned out to be surprisingly robust against random spot charge perturbation. Our study suggests that ensuring spot charge errors as small as 1-2% as is commonly aimed at in conventional proton therapy machines, is clinically not strictly needed. © 2017 American Association of Physicists in Medicine.
Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT
NASA Astrophysics Data System (ADS)
Muryn, John S.; Morgan, Ashraf G.; Segars, W. P.; Liptak, Chris L.; Dong, Frank F.; Primak, Andrew N.; Li, Xiang
2015-03-01
In Monte Carlo simulation of organ dose for a chest CT scan, many input parameters are required (e.g., half-value layer of the x-ray energy spectrum, effective beam width, and anatomical coverage of the scan). The input parameter values are provided by the manufacturer, measured experimentally, or determined based on typical clinical practices. The goal of this study was to assess the uncertainties in Monte Carlo simulated organ dose as a result of using input parameter values that deviate from the truth (clinical reality). Organ dose from a chest CT scan was simulated for a standard-size female phantom using a set of reference input parameter values (treated as the truth). To emulate the situation in which the input parameter values used by the researcher may deviate from the truth, additional simulations were performed in which errors were purposefully introduced into the input parameter values, the effects of which on organ dose per CTDIvol were analyzed. Our study showed that when errors in half value layer were within ± 0.5 mm Al, the errors in organ dose per CTDIvol were less than 6%. Errors in effective beam width of up to 3 mm had negligible effect (< 2.5%) on organ dose. In contrast, when the assumed anatomical center of the patient deviated from the true anatomical center by 5 cm, organ dose errors of up to 20% were introduced. Lastly, when the assumed extra scan length was longer by 4 cm than the true value, dose errors of up to 160% were found. The results answer the important question: to what level of accuracy each input parameter needs to be determined in order to obtain accurate organ dose results.
Durham, Spencer H; Badowski, Melissa E; Liedtke, Michelle D; Rathbun, R Chris; Pecora Fulco, Patricia
2017-05-01
Patients infected with human immunodeficiency virus (HIV) admitted to the hospital have complex antiretroviral therapy (ART) regimens with an increased medication error rate upon admission. This report provides a resource for clinicians managing HIV-infected patients and ART in the inpatient setting. A survey of the authors was conducted to evaluate common issues that arise during an acute hospitalization for HIV-infected patients. After a group consensus, a review of the medical literature was performed to determine the supporting evidence for the following HIV-associated hospital queries: admission/discharge orders, antiretroviral hospital formularies, laboratory monitoring, altered hepatic/renal function, drug-drug interactions (DDIs), enteral administration, and therapeutic drug monitoring. With any hospital admission for an HIV-infected patient, a specific set of procedures should be followed including a thorough admission medication history and communication with the ambulatory HIV provider to avoid omissions or substitutions in the ART regimen. DDIs are common and should be reviewed at all transitions of care during the hospital admission. ART may be continued if enteral nutrition with a feeding tube is deemed necessary, but the entire regimen should be discontinued if no oral access is available for a prolonged period. Therapeutic drug monitoring is not generally recommended but, if available, should be considered in unique clinical scenarios where antiretroviral pharmacokinetics are difficult to predict. ART may need adjustment if hepatic or renal insufficiency ensues. Treatment of hospitalized patients with HIV is highly complex. HIV-infected patients are at high risk for medication errors during various transitions of care. Baseline knowledge of the principles of antiretroviral pharmacotherapy is necessary for clinicians managing acutely ill HIV-infected patients to avoid medication errors, identify DDIs, and correctly dose medications if organ dysfunction arises. Timely ambulatory follow-up is essential to prevent readmissions and facilitate improved transitions of care. © 2017 Pharmacotherapy Publications, Inc.
Passarge, Michelle; Fix, Michael K; Manser, Peter; Stampanoni, Marco F M; Siebers, Jeffrey V
2017-04-01
To develop a robust and efficient process that detects relevant dose errors (dose errors of ≥5%) in external beam radiation therapy and directly indicates the origin of the error. The process is illustrated in the context of electronic portal imaging device (EPID)-based angle-resolved volumetric-modulated arc therapy (VMAT) quality assurance (QA), particularly as would be implemented in a real-time monitoring program. A Swiss cheese error detection (SCED) method was created as a paradigm for a cine EPID-based during-treatment QA. For VMAT, the method compares a treatment plan-based reference set of EPID images with images acquired over each 2° gantry angle interval. The process utilizes a sequence of independent consecutively executed error detection tests: an aperture check that verifies in-field radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment check to examine if rotation, scaling, and translation are within tolerances; pixel intensity check containing the standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each check were determined. To test the SCED method, 12 different types of errors were selected to modify the original plan. A series of angle-resolved predicted EPID images were artificially generated for each test case, resulting in a sequence of precalculated frames for each modified treatment plan. The SCED method was applied multiple times for each test case to assess the ability to detect introduced plan variations. To compare the performance of the SCED process with that of a standard gamma analysis, both error detection methods were applied to the generated test cases with realistic noise variations. Averaged over ten test runs, 95.1% of all plan variations that resulted in relevant patient dose errors were detected within 2° and 100% within 14° (<4% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 89.1% were detected by the SCED method within 2°. Based on the type of check that detected the error, determination of error sources was achieved. With noise ranging from no random noise to four times the established noise value, the averaged relevant dose error detection rate of the SCED method was between 94.0% and 95.8% and that of gamma between 82.8% and 89.8%. An EPID-frame-based error detection process for VMAT deliveries was successfully designed and tested via simulations. The SCED method was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of relevant dose errors. Compared to a typical (3%, 3 mm) gamma analysis, the SCED method produced a higher detection rate for all introduced dose errors, identified errors in an earlier stage, displayed a higher robustness to noise variations, and indicated the error source. © 2017 American Association of Physicists in Medicine.
Quantitative evaluation of patient-specific quality assurance using online dosimetry system
NASA Astrophysics Data System (ADS)
Jung, Jae-Yong; Shin, Young-Ju; Sohn, Seung-Chang; Min, Jung-Whan; Kim, Yon-Lae; Kim, Dong-Su; Choe, Bo-Young; Suh, Tae-Suk
2018-01-01
In this study, we investigated the clinical performance of an online dosimetry system (Mobius FX system, MFX) by 1) dosimetric plan verification using gamma passing rates and dose volume metrics and 2) error-detection capability evaluation by deliberately introduced machine error. Eighteen volumetric modulated arc therapy (VMAT) plans were studied. To evaluate the clinical performance of the MFX, we used gamma analysis and dose volume histogram (DVH) analysis. In addition, to evaluate the error-detection capability, we used gamma analysis and DVH analysis utilizing three types of deliberately introduced errors (Type 1: gantry angle-independent multi-leaf collimator (MLC) error, Type 2: gantry angle-dependent MLC error, and Type 3: gantry angle error). A dosimetric verification comparison of physical dosimetry system (Delt4PT) and online dosimetry system (MFX), gamma passing rates of the two dosimetry systems showed very good agreement with treatment planning system (TPS) calculation. For the average dose difference between the TPS calculation and the MFX measurement, most of the dose metrics showed good agreement within a tolerance of 3%. For the error-detection comparison of Delta4PT and MFX, the gamma passing rates of the two dosimetry systems did not meet the 90% acceptance criterion with the magnitude of error exceeding 2 mm and 1.5 ◦, respectively, for error plans of Types 1, 2, and 3. For delivery with all error types, the average dose difference of PTV due to error magnitude showed good agreement between calculated TPS and measured MFX within 1%. Overall, the results of the online dosimetry system showed very good agreement with those of the physical dosimetry system. Our results suggest that a log file-based online dosimetry system is a very suitable verification tool for accurate and efficient clinical routines for patient-specific quality assurance (QA).
Smith, Kenneth J; Handler, Steven M; Kapoor, Wishwa N; Martich, G Daniel; Reddy, Vivek K; Clark, Sunday
2016-07-01
This study sought to determine the effects of automated primary care physician (PCP) communication and patient safety tools, including computerized discharge medication reconciliation, on discharge medication errors and posthospitalization patient outcomes, using a pre-post quasi-experimental study design, in hospitalized medical patients with ≥2 comorbidities and ≥5 chronic medications, at a single center. The primary outcome was discharge medication errors, compared before and after rollout of these tools. Secondary outcomes were 30-day rehospitalization, emergency department visit, and PCP follow-up visit rates. This study found that discharge medication errors were lower post intervention (odds ratio = 0.57; 95% confidence interval = 0.44-0.74; P < .001). Clinically important errors, with the potential for serious or life-threatening harm, and 30-day patient outcomes were not significantly different between study periods. Thus, automated health system-based communication and patient safety tools, including computerized discharge medication reconciliation, decreased hospital discharge medication errors in medically complex patients. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calabrese, Edward J., E-mail: edwardc@schoolph.uma
This paper reveals that nearly 25 years after the used Russell's dose-rate data to support the adoption of the linear-no-threshold (LNT) dose response model for genetic and cancer risk assessment, Russell acknowledged a significant under-reporting of the mutation rate of the historical control group. This error, which was unknown to BEIR I, had profound implications, leading it to incorrectly adopt the LNT model, which was a decision that profoundly changed the course of risk assessment for radiation and chemicals to the present. -- Highlights: • The BEAR I Genetics Panel made an error in denying dose rate for mutation. •more » The BEIR I Genetics Subcommittee attempted to correct this dose rate error. • The control group used for risk assessment by BEIR I is now known to be in error. • Correcting this error contradicts the LNT, supporting a threshold model.« less
Cao, Hui; Stetson, Peter; Hripcsak, George
2003-01-01
In this study, we assessed the explicit reporting of medical errors in the electronic record. We looked for cases in which the provider explicitly stated that he or she or another provider had committed an error. The advantage of the technique is that it is not limited to a specific type of error. Our goals were to 1) measure the rate at which medical errors were documented in medical records, and 2) characterize the types of errors that were reported.
Jacobs, Jeffrey P
2008-12-01
The Multi-Societal Database Committee for Pediatric and Congenital Heart Disease was established in 2005 with the goal of providing the infrastructure, spanning geographical and subspecialty boundaries, for collaboration between health care professionals interested in the analysis of outcomes of treatments provided to patients with congenital cardiac disease, with the ultimate aim of improvement in the quality of care provided to these patients. The purpose of these collaborative efforts is to promote the highest quality comprehensive cardiac care to all patients with congenital heart disease, from the fetus to the adult, regardless of the patient's economic means, with an emphasis on excellence in teaching, research and community service. This manuscript provides the Introduction to the 2008 Supplement to Cardiology in the Young titled: "Databases and The Assessment of Complications associated with the Treatment of Patients with Congenital Cardiac Disease". This Supplement was prepared by The Multi-Societal Database Committee for Pediatric and Congenital Heart Disease. The Multi-Societal Database Committee for Pediatric and Congenital Heart Disease offers the following definition of the term "Complication": "A complication is an event or occurrence that is associated with a disease or a healthcare intervention, is a departure from the desired course of events, and may cause, or be associated with, suboptimal outcome. A complication does not necessarily represent a breech in the standard of care that constitutes medical negligence or medical malpractice. An operative or procedural complication is any complication, regardless of cause, occurring (1) within 30 days after surgery or intervention in or out of the hospital, or (2) after 30 days during the same hospitalization subsequent to the operation or intervention. Operative and procedural complications include both intraoperative/intraprocedural complications and postoperative/postprocedural complications in this time interval." The Multi-Societal Database Committee for Pediatric and Congenital Heart Disease offers the following definition of the term "Adverse Event": "An adverse event is a complication that is associated with a healthcare intervention and is associated with suboptimal outcome. Adverse events represent a subset of complications. Not all medical errors result in an adverse event; the administration of an incorrect dose of a medication is a medical error, but it does not always result in an adverse event. Similarly, not all adverse events are the result of medical error. A child may develop pneumonia after an atrial septal defect repair despite intra- and peri-operative management that is free of error. Complications of the underlying disease state, which are not related to a medical intervention, are not adverse events. For example, a patient who presents for medical care with metastatic lung cancer has already developed a complication (Metastatic spread) of the primary lung cancer without any healthcare intervention. Furthermore, complications not associated with suboptimal outcome or harm are not adverse events and are known as no harm events. The patient who receives an incorrect dose of a medication without harm has experienced a no harm event, but not an adverse event." Based on the above definitions, it is apparent that The Multi-Societal Database Committee for Pediatric and Congenital Heart Disease has taken an inclusive approach to defining the universe of complications. Complications may or may not be associated with healthcare intervention and may or may not be associated with suboptimal outcome. Meanwhile, adverse events must be associated with healthcare intervention and must be associated with suboptimal outcome.
Medication errors in home care: a qualitative focus group study.
Berland, Astrid; Bentsen, Signe Berit
2017-11-01
To explore registered nurses' experiences of medication errors and patient safety in home care. The focus of care for older patients has shifted from institutional care towards a model of home care. Medication errors are common in this situation and can result in patient morbidity and mortality. An exploratory qualitative design with focus group interviews was used. Four focus group interviews were conducted with 20 registered nurses in home care. The data were analysed using content analysis. Five categories were identified as follows: lack of information, lack of competence, reporting medication errors, trade name products vs. generic name products, and improving routines. Medication errors occur frequently in home care and can threaten the safety of patients. Insufficient exchange of information and poor communication between the specialist and home-care health services, and between general practitioners and healthcare workers can lead to medication errors. A lack of competence in healthcare workers can also lead to medication errors. To prevent these, it is important that there should be up-to-date information and communication between healthcare workers during the transfer of patients from specialist to home care. Ensuring competence among healthcare workers with regard to medication is also important. In addition, there should be openness and accurate reporting of medication errors, as well as in setting routines for the preparation, alteration and administration of medicines. To prevent medication errors in home care, up-to-date information and communication between healthcare workers is important when patients are transferred from specialist to home care. It is also important to ensure adequate competence with regard to medication, and that there should be openness when medication errors occur, as well as in setting routines for the preparation, alteration and administration of medications. © 2017 John Wiley & Sons Ltd.
MEDICAL ERROR: CIVIL AND LEGAL ASPECT.
Buletsa, S; Drozd, O; Yunin, O; Mohilevskyi, L
2018-03-01
The scientific article is focused on the research of the notion of medical error, medical and legal aspects of this notion have been considered. The necessity of the legislative consolidation of the notion of «medical error» and criteria of its legal estimation have been grounded. In the process of writing a scientific article, we used the empirical method, general scientific and comparative legal methods. A comparison of the concept of medical error in civil and legal aspects was made from the point of view of Ukrainian, European and American scientists. It has been marked that the problem of medical errors is known since ancient times and in the whole world, in fact without regard to the level of development of medicine, there is no country, where doctors never make errors. According to the statistics, medical errors in the world are included in the first five reasons of death rate. At the same time the grant of medical services practically concerns all people. As a man and his life, health in Ukraine are acknowledged by a higher social value, medical services must be of high-quality and effective. The grant of not quality medical services causes harm to the health, and sometimes the lives of people; it may result in injury or even death. The right to the health protection is one of the fundamental human rights assured by the Constitution of Ukraine; therefore the issue of medical errors and liability for them is extremely relevant. The authors make conclusions, that the definition of the notion of «medical error» must get the legal consolidation. Besides, the legal estimation of medical errors must be based on the single principles enshrined in the legislation and confirmed by judicial practice.
Reducing medication errors in critical care: a multimodal approach
Kruer, Rachel M; Jarrell, Andrew S; Latif, Asad
2014-01-01
The Institute of Medicine has reported that medication errors are the single most common type of error in health care, representing 19% of all adverse events, while accounting for over 7,000 deaths annually. The frequency of medication errors in adult intensive care units can be as high as 947 per 1,000 patient-days, with a median of 105.9 per 1,000 patient-days. The formulation of drugs is a potential contributor to medication errors. Challenges related to drug formulation are specific to the various routes of medication administration, though errors associated with medication appearance and labeling occur among all drug formulations and routes of administration. Addressing these multifaceted challenges requires a multimodal approach. Changes in technology, training, systems, and safety culture are all strategies to potentially reduce medication errors related to drug formulation in the intensive care unit. PMID:25210478
Long-term care physical environments--effect on medication errors.
Mahmood, Atiya; Chaudhury, Habib; Gaumont, Alana; Rust, Tiana
2012-01-01
Few studies examine physical environmental factors and their effects on staff health, effectiveness, work errors and job satisfaction. To address this gap, this study aims to examine environmental features and their role in medication and nursing errors in long-term care facilities. A mixed methodological strategy was used. Data were collected via focus groups, observing medication preparation and administration, and a nursing staff survey in four facilities. The paper reveals that, during the medication preparation phase, physical design, such as medication room layout, is a major source of potential errors. During medication administration, social environment is more likely to contribute to errors. Interruptions, noise and staff shortages were particular problems. The survey's relatively small sample size needs to be considered when interpreting the findings. Also, actual error data could not be included as existing records were incomplete. The study offers several relatively low-cost recommendations to help staff reduce medication errors. Physical environmental factors are important when addressing measures to reduce errors. The findings of this study underscore the fact that the physical environment's influence on the possibility of medication errors is often neglected. This study contributes to the scarce empirical literature examining the relationship between physical design and patient safety.
Medication Administration Errors in Nursing Homes Using an Automated Medication Dispensing System
van den Bemt, Patricia M.L.A.; Idzinga, Jetske C.; Robertz, Hans; Kormelink, Dennis Groot; Pels, Neske
2009-01-01
Objective To identify the frequency of medication administration errors as well as their potential risk factors in nursing homes using a distribution robot. Design The study was a prospective, observational study conducted within three nursing homes in the Netherlands caring for 180 individuals. Measurements Medication errors were measured using the disguised observation technique. Types of medication errors were described. The correlation between several potential risk factors and the occurrence of medication errors was studied to identify potential causes for the errors. Results In total 2,025 medication administrations to 127 clients were observed. In these administrations 428 errors were observed (21.2%). The most frequently occurring types of errors were use of wrong administration techniques (especially incorrect crushing of medication and not supervising the intake of medication) and wrong time errors (administering the medication at least 1 h early or late).The potential risk factors female gender (odds ratio (OR) 1.39; 95% confidence interval (CI) 1.05–1.83), ATC medication class antibiotics (OR 11.11; 95% CI 2.66–46.50), medication crushed (OR 7.83; 95% CI 5.40–11.36), number of dosages/day/client (OR 1.03; 95% CI 1.01–1.05), nursing home 2 (OR 3.97; 95% CI 2.86–5.50), medication not supplied by distribution robot (OR 2.92; 95% CI 2.04–4.18), time classes “7–10 am” (OR 2.28; 95% CI 1.50–3.47) and “10 am-2 pm” (OR 1.96; 1.18–3.27) and day of the week “Wednesday” (OR 1.46; 95% CI 1.03–2.07) are associated with a higher risk of administration errors. Conclusions Medication administration in nursing homes is prone to many errors. This study indicates that the handling of the medication after removing it from the robot packaging may contribute to this high error frequency, which may be reduced by training of nurse attendants, by automated clinical decision support and by measures to reduce workload. PMID:19390109
Real-time dosimetry in radiotherapy using tailored optical fibers
NASA Astrophysics Data System (ADS)
Rahman, A. K. M. Mizanur; Zubair, H. T.; Begum, Mahfuza; Abdul-Rashid, H. A.; Yusoff, Z.; Omar, Nasr Y. M.; Ung, N. M.; Mat-Sharif, K. A.; Bradley, D. A.
2016-05-01
Real-time dosimetry plays an important role for accurate patient-dose measurement during radiotherapy. A tiny piece of laboratory fabricated Ge-doped optical fiber has been investigated as a radioluminescence (RL) sensor for real-time dosimetry over the dose range from 1 Gy to 8 Gy under 6 MV photon beam by LINAC. Fiber-coupled software-based RL prototype system was used to assess essential dosimetric characteristics including dose response linearity, dose rate dependency, sensitivity, repeatability and output dependence on field sizes. The consistency level of RL photon counts versus dose rate was also compared with that of standard Al2O3:C chips. Sensitivity of Ge-doped fiber were found to be sufficiently sensitive for practical use and also provided linear dose responses for various dose rates from 100 cGy/min to 600 cGy/min using both 6 MV photon and 6 MeV electron beams. SEM-EDX analysis was performed to identify Ge-dopant concentration level within the optical fiber RL material. Accumulated doses were also estimated using simple integral technique and the error was found to be around less than 1% under dissimilar dose rates or repeat measurements. The evaluation of the Ge-doped optical fiber based RL dosimeter system indicates its potential in medical dosimetry.
Nurses' attitudes and perceived barriers to the reporting of medication administration errors.
Yung, Hai-Peng; Yu, Shu; Chu, Chi; Hou, I-Ching; Tang, Fu-In
2016-07-01
(1) To explore the attitudes and perceived barriers to reporting medication administration errors and (2) to understand the characteristics of - and nurses' feelings - about error reports. Under-reporting of medication administration errors is a global concern related to the safety of patient care. Understanding nurses' attitudes and perceived barriers to error reporting is the initial step to increasing the reporting rate. A cross-sectional, descriptive survey with a self-administered questionnaire was completed by the nurses of a medical centre hospital in Taiwan. A total of 306 nurses participated in the study. Nurses' attitudes towards medication administration error reporting were inclined towards positive. The major perceived barrier was fear of the consequences after reporting. The results demonstrated that 88.9% of medication administration errors were reported orally, whereas 19.0% were reported through the hospital internet system. Self-recrimination was the common feeling of nurses after the commission of an medication administration error. Even if hospital management encourages errors to be reported without recrimination, nurses' attitudes toward medication administration error reporting are not very positive and fear is the most prominent barrier contributing to underreporting. Nursing managers should establish anonymous reporting systems and counselling classes to create a secure atmosphere to reduce nurses' fear and provide incentives to encourage reporting. © 2016 John Wiley & Sons Ltd.
Policies on documentation and disciplinary action in hospital pharmacies after a medication error.
Bauman, A N; Pedersen, C A; Schommer, J C; Griffith, N L
2001-06-15
Hospital pharmacies were surveyed about policies on medication error documentation and actions taken against pharmacists involved in an error. The survey was mailed to 500 randomly selected hospital pharmacy directors in the United States. Data were collected on the existence of medication error reporting policies, what types of errors were documented and how, and hospital demographics. The response rate was 28%. Virtually all of the hospitals had policies and procedures for medication error reporting. Most commonly, documentation of oral and written reprimand was placed in the personnel file of a pharmacist involved in an error. One sixth of respondents had no policy on documentation or disciplinary action in the event of an error. Approximately one fourth of respondents reported that suspension or termination had been used as a form of disciplinary action; legal action was rarely used. Many respondents said errors that caused harm (42%) or death (40%) to the patient were documented in the personnel file, but 34% of hospitals did not document errors in the personnel file regardless of error type. Nearly three fourths of respondents differentiated between errors caught and not caught before a medication leaves the pharmacy and between errors caught and not caught before administration to the patient. More emphasis is needed on documentation of medication errors in hospital pharmacies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kertzscher, Gustavo, E-mail: guke@dtu.dk; Andersen, Claus E., E-mail: clan@dtu.dk; Tanderup, Kari, E-mail: karitand@rm.dk
Purpose: This study presents an adaptive error detection algorithm (AEDA) for real-timein vivo point dosimetry during high dose rate (HDR) or pulsed dose rate (PDR) brachytherapy (BT) where the error identification, in contrast to existing approaches, does not depend on an a priori reconstruction of the dosimeter position. Instead, the treatment is judged based on dose rate comparisons between measurements and calculations of the most viable dosimeter position provided by the AEDA in a data driven approach. As a result, the AEDA compensates for false error cases related to systematic effects of the dosimeter position reconstruction. Given its nearly exclusivemore » dependence on stable dosimeter positioning, the AEDA allows for a substantially simplified and time efficient real-time in vivo BT dosimetry implementation. Methods: In the event of a measured potential treatment error, the AEDA proposes the most viable dosimeter position out of alternatives to the original reconstruction by means of a data driven matching procedure between dose rate distributions. If measured dose rates do not differ significantly from the most viable alternative, the initial error indication may be attributed to a mispositioned or misreconstructed dosimeter (false error). However, if the error declaration persists, no viable dosimeter position can be found to explain the error, hence the discrepancy is more likely to originate from a misplaced or misreconstructed source applicator or from erroneously connected source guide tubes (true error). Results: The AEDA applied on twoin vivo dosimetry implementations for pulsed dose rate BT demonstrated that the AEDA correctly described effects responsible for initial error indications. The AEDA was able to correctly identify the major part of all permutations of simulated guide tube swap errors and simulated shifts of individual needles from the original reconstruction. Unidentified errors corresponded to scenarios where the dosimeter position was sufficiently symmetric with respect to error and no-error source position constellations. The AEDA was able to correctly identify all false errors represented by mispositioned dosimeters contrary to an error detection algorithm relying on the original reconstruction. Conclusions: The study demonstrates that the AEDA error identification during HDR/PDR BT relies on a stable dosimeter position rather than on an accurate dosimeter reconstruction, and the AEDA’s capacity to distinguish between true and false error scenarios. The study further shows that the AEDA can offer guidance in decision making in the event of potential errors detected with real-timein vivo point dosimetry.« less
Westbrook, Johanna I; Li, Ling; Lehnbom, Elin C; Baysari, Melissa T; Braithwaite, Jeffrey; Burke, Rosemary; Conn, Chris; Day, Richard O
2015-02-01
To (i) compare medication errors identified at audit and observation with medication incident reports; (ii) identify differences between two hospitals in incident report frequency and medication error rates; (iii) identify prescribing error detection rates by staff. Audit of 3291 patient records at two hospitals to identify prescribing errors and evidence of their detection by staff. Medication administration errors were identified from a direct observational study of 180 nurses administering 7451 medications. Severity of errors was classified. Those likely to lead to patient harm were categorized as 'clinically important'. Two major academic teaching hospitals in Sydney, Australia. Rates of medication errors identified from audit and from direct observation were compared with reported medication incident reports. A total of 12 567 prescribing errors were identified at audit. Of these 1.2/1000 errors (95% CI: 0.6-1.8) had incident reports. Clinically important prescribing errors (n = 539) were detected by staff at a rate of 218.9/1000 (95% CI: 184.0-253.8), but only 13.0/1000 (95% CI: 3.4-22.5) were reported. 78.1% (n = 421) of clinically important prescribing errors were not detected. A total of 2043 drug administrations (27.4%; 95% CI: 26.4-28.4%) contained ≥ 1 errors; none had an incident report. Hospital A had a higher frequency of incident reports than Hospital B, but a lower rate of errors at audit. Prescribing errors with the potential to cause harm frequently go undetected. Reported incidents do not reflect the profile of medication errors which occur in hospitals or the underlying rates. This demonstrates the inaccuracy of using incident frequency to compare patient risk or quality performance within or across hospitals. New approaches including data mining of electronic clinical information systems are required to support more effective medication error detection and mitigation. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care.
The incidence and severity of errors in pharmacist-written discharge medication orders.
Onatade, Raliat; Sawieres, Sara; Veck, Alexandra; Smith, Lindsay; Gore, Shivani; Al-Azeib, Sumiah
2017-08-01
Background Errors in discharge prescriptions are problematic. When hospital pharmacists write discharge prescriptions improvements are seen in the quality and efficiency of discharge. There is limited information on the incidence of errors in pharmacists' medication orders. Objective To investigate the extent and clinical significance of errors in pharmacist-written discharge medication orders. Setting 1000-bed teaching hospital in London, UK. Method Pharmacists in this London hospital routinely write discharge medication orders as part of the clinical pharmacy service. Convenient days, based on researcher availability, between October 2013 and January 2014 were selected. Pre-registration pharmacists reviewed all discharge medication orders written by pharmacists on these days and identified discrepancies between the medication history, inpatient chart, patient records and discharge summary. A senior clinical pharmacist confirmed the presence of an error. Each error was assigned a potential clinical significance rating (based on the NCCMERP scale) by a physician and an independent senior clinical pharmacist, working separately. Main outcome measure Incidence of errors in pharmacist-written discharge medication orders. Results 509 prescriptions, written by 51 pharmacists, containing 4258 discharge medication orders were assessed (8.4 orders per prescription). Ten prescriptions (2%), contained a total of ten erroneous orders (order error rate-0.2%). The pharmacist considered that one error had the potential to cause temporary harm (0.02% of all orders). The physician did not rate any of the errors with the potential to cause harm. Conclusion The incidence of errors in pharmacists' discharge medication orders was low. The quality, safety and policy implications of pharmacists routinely writing discharge medication orders should be further explored.
CE: Nursing's Evolving Role in Patient Safety.
Kowalski, Sonya L; Anthony, Maureen
2017-02-01
: Background: In its 1999 report To Err Is Human: Building a Safer Health System, the Institute of Medicine (IOM) suggested that between 44,000 and 98,000 Americans die annually as a result of medical errors. The report urged health care institutions to break the silence surrounding such errors and to implement changes that would promote a culture of safety. Our aim in conducting this content analysis of AJN articles was to explore the nurse's historical and contemporary role in promoting patient safety. We chose to focus on AJN because, as the oldest continuously published nursing journal, it provided a unique opportunity for us to view trends in nursing practice over more than 100 years. We reviewed all AJN tables of contents from 1900 through 2015, identifying for inclusion articles with titles that suggested a focus on nursing care, patient safety, or clinical content. We then read and analyzed each of the final 1,086 articles over a period of nine months. Our content analysis indicates that the early articles (from 1900 through 1920) focused on such safety measures as asepsis and the newly understood germ theory. In the 1930s, articles proposed methods for preventing medication errors and encouraged the development of written procedures to standardize care. During World War II, nurse authors identified improved patient survival rates with the use of "shock wards" and recovery rooms. The 1950s saw the emergence of progressive patient care initiatives, through which patients were assigned to various levels of care (intensive, intermediate, self, long-term, or home care) based on patient acuity. The 1960s brought increasingly complex equipment and medication regimens, which created safety problems. Hospital-acquired infections were recognized. Unit-dose medication was instituted in the 1970s. In the next two decades, medication and nursing-procedure safety were emphasized. From 2000 to 2015, articles looked beyond human performance as causes of health care errors to systemic factors, such as poor communication, patient-nurse ratios, provider skill mix, disruptive or inappropriate provider behavior, shift work, and long working hours. Emphasis on patient safety increased as patient care became more complex. As nurses developed a professional identity, they often put a spotlight on safety concerns and solutions. The IOM report, which encouraged research focused on systemic solutions to errors, was instrumental in furthering the very culture of safety that the nursing profession had championed.
Nurses' attitude and intention of medication administration error reporting.
Hung, Chang-Chiao; Chu, Tsui-Ping; Lee, Bih-O; Hsiao, Chia-Chi
2016-02-01
The Aims of this study were to explore the effects of nurses' attitudes and intentions regarding medication administration error reporting on actual reporting behaviours. Underreporting of medication errors is still a common occurrence. Whether attitude and intention towards medication administration error reporting connect to actual reporting behaviours remain unclear. This study used a cross-sectional design with self-administered questionnaires, and the theory of planned behaviour was used as the framework for this study. A total of 596 staff nurses who worked in general wards and intensive care units in a hospital were invited to participate in this study. The researchers used the instruments measuring nurses' attitude, nurse managers' and co-workers' attitude, report control, and nurses' intention to predict nurses' actual reporting behaviours. Data were collected from September-November 2013. Path analyses were used to examine the hypothesized model. Of the 596 nurses invited to participate, 548 (92%) completed and returned a valid questionnaire. The findings indicated that nurse managers' and co-workers' attitudes are predictors for nurses' attitudes towards medication administration error reporting. Nurses' attitudes also influenced their intention to report medication administration errors; however, no connection was found between intention and actual reporting behaviour. The findings reflected links among colleague perspectives, nurses' attitudes, and intention to report medication administration errors. The researchers suggest that hospitals should increase nurses' awareness and recognition of error occurrence. Regardless of nurse managers' and co-workers' attitudes towards medication administration error reporting, nurses are likely to report medication administration errors if they detect them. Management of medication administration errors should focus on increasing nurses' awareness and recognition of error occurrence. © 2015 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, H; Chen, J; Pouliot, J
2015-06-15
Purpose: Deformable image registration (DIR) is a powerful tool with the potential to deformably map dose from one computed-tomography (CT) image to another. Errors in the DIR, however, will produce errors in the transferred dose distribution. We have proposed a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), which predicts voxel-specific dose mapping errors on a patient-by-patient basis. This work validates the effectiveness of AUTODIRECT to predict dose mapping errors with virtual and physical phantom datasets. Methods: AUTODIRECT requires 4 inputs: moving and fixed CT images and two noise scans of a water phantom (for noise characterization). Then,more » AUTODIRECT uses algorithms to generate test deformations and applies them to the moving and fixed images (along with processing) to digitally create sets of test images, with known ground-truth deformations that are similar to the actual one. The clinical DIR algorithm is then applied to these test image sets (currently 4) . From these tests, AUTODIRECT generates spatial and dose uncertainty estimates for each image voxel based on a Student’s t distribution. This work compares these uncertainty estimates to the actual errors made by the Velocity Deformable Multi Pass algorithm on 11 virtual and 1 physical phantom datasets. Results: For 11 of the 12 tests, the predicted dose error distributions from AUTODIRECT are well matched to the actual error distributions within 1–6% for 10 virtual phantoms, and 9% for the physical phantom. For one of the cases though, the predictions underestimated the errors in the tail of the distribution. Conclusion: Overall, the AUTODIRECT algorithm performed well on the 12 phantom cases for Velocity and was shown to generate accurate estimates of dose warping uncertainty. AUTODIRECT is able to automatically generate patient-, organ- , and voxel-specific DIR uncertainty estimates. This ability would be useful for patient-specific DIR quality assurance.« less
Markovic, Marija; Mathis, A. Scott; Ghin, Hoytin Lee; Gardiner, Michelle; Fahim, Germin
2017-01-01
Purpose: To compare the medication history error rate of the emergency department (ED) pharmacy technician with that of nursing staff and to describe the workflow environment. Methods: Fifty medication histories performed by an ED nurse followed by the pharmacy technician were evaluated for discrepancies (RN-PT group). A separate 50 medication histories performed by the pharmacy technician and observed with necessary intervention by the ED pharmacist were evaluated for discrepancies (PT-RPh group). Discrepancies were totaled and categorized by type of error and therapeutic category of the medication. The workflow description was obtained by observation and staff interview. Results: A total of 474 medications in the RN-PT group and 521 in the PT-RPh group were evaluated. Nurses made at least one error in all 50 medication histories (100%), compared to 18 medication histories for the pharmacy technician (36%). In the RN-PT group, 408 medications had at least one error, corresponding to an accuracy rate of 14% for nurses. In the PT-RPh group, 30 medications had an error, corresponding to an accuracy rate of 94.4% for the pharmacy technician (P < 0.0001). The most common error made by nurses was a missing medication (n = 109), while the most common error for the pharmacy technician was a wrong medication frequency (n = 19). The most common drug class with documented errors for ED nurses was cardiovascular medications (n = 100), while the pharmacy technician made the most errors in gastrointestinal medications (n = 11). Conclusion: Medication histories obtained by the pharmacy technician were significantly more accurate than those obtained by nurses in the emergency department. PMID:28090164
Obligation towards medical errors disclosure at a tertiary care hospital in Dubai, UAE
Zaghloul, Ashraf Ahmad; Rahman, Syed Azizur; Abou El-Enein, Nagwa Younes
2016-01-01
OBJECTIVE: The study aimed to identify healthcare providers’ obligation towards medical errors disclosure as well as to study the association between the severity of the medical error and the intention to disclose the error to the patients and their families. DESIGN: A cross-sectional study design was followed to identify the magnitude of disclosure among healthcare providers in different departments at a randomly selected tertiary care hospital in Dubai. SETTING AND PARTICIPANTS: The total sample size accounted for 106 respondents. Data were collected using a questionnaire composed of two sections namely; demographic variables of the respondents and a section which included variables relevant to medical error disclosure. RESULTS: Statistical analysis yielded significant association between the obligation to disclose medical errors with male healthcare providers (X2 = 5.1), and being a physician (X2 = 19.3). Obligation towards medical errors disclosure was significantly associated with those healthcare providers who had not committed any medical errors during the past year (X2 = 9.8), and any type of medical error regardless the cause, extent of harm (X2 = 8.7). Variables included in the binary logistic regression model were; status (Exp β (Physician) = 0.39, 95% CI 0.16–0.97), gender (Exp β (Male) = 4.81, 95% CI 1.84–12.54), and medical errors during the last year (Exp β (None) = 2.11, 95% CI 0.6–2.3). CONCLUSION: Education and training of physicians about disclosure conversations needs to start as early as medical school. Like the training in other competencies required of physicians, education in communicating about medical errors could help reduce physicians’ apprehension and make them more comfortable with disclosure conversations. PMID:27567766
Time trend of injection drug errors before and after implementation of bar-code verification system.
Sakushima, Ken; Umeki, Reona; Endoh, Akira; Ito, Yoichi M; Nasuhara, Yasuyuki
2015-01-01
Bar-code technology, used for verification of patients and their medication, could prevent medication errors in clinical practice. Retrospective analysis of electronically stored medical error reports was conducted in a university hospital. The number of reported medication errors of injected drugs, including wrong drug administration and administration to the wrong patient, was compared before and after implementation of the bar-code verification system for inpatient care. A total of 2867 error reports associated with injection drugs were extracted. Wrong patient errors decreased significantly after implementation of the bar-code verification system (17.4/year vs. 4.5/year, p< 0.05), although wrong drug errors did not decrease sufficiently (24.2/year vs. 20.3/year). The source of medication errors due to wrong drugs was drug preparation in hospital wards. Bar-code medication administration is effective for prevention of wrong patient errors. However, ordinary bar-code verification systems are limited in their ability to prevent incorrect drug preparation in hospital wards.
Ihle, Andreas; Inauen, Jennifer; Scholz, Urte; König, Claudia; Holzer, Barbara; Zimmerli, Lukas; Battegay, Edouard; Tobias, Robert; Kliegel, Matthias
2017-01-01
We investigated the relations of self-rated omission errors (i.e., forgetting to take one's medication) and commission errors (i.e., unnecessary repetitions of medication intake because of forgetting that it has already been taken) in medication adherence in multimorbidity to prospective and retrospective memory performance. Moreover, we examined whether these relations were moderated by the number of medications that had to be taken. Eighty-four patients with multimorbidity (aged 28-84 years, M = 62.4) reported medication adherence regarding the last seven days and the number of medications they had to take. In addition, we administered psychometric tests on prospective memory (PM) and retrospective memory performance. We found that reported omission errors in medication adherence were related significantly to lower PM performance. This relationship was increased in individuals with a lower number of medications. In comparison, reported commission errors in medication adherence were related significantly to lower retrospective memory performance. This relationship was increased in individuals with a larger number of medications. Present data suggest that omission errors in medication adherence in multimorbidity may reflect primarily PM errors, particularly if few medications have to be taken, while commission errors may reflect mainly retrospective memory failures, especially with a large number of medications that need to be taken as prescribed. From an applied neuropsychological perspective, these results underline the importance of trying to enhance PM and retrospective memory performance in patients with multimorbidity.
Sensitivity in error detection of patient specific QA tools for IMRT plans
NASA Astrophysics Data System (ADS)
Lat, S. Z.; Suriyapee, S.; Sanghangthum, T.
2016-03-01
The high complexity of dose calculation in treatment planning and accurate delivery of IMRT plan need high precision of verification method. The purpose of this study is to investigate error detection capability of patient specific QA tools for IMRT plans. The two H&N and two prostate IMRT plans with MapCHECK2 and portal dosimetry QA tools were studied. Measurements were undertaken for original and modified plans with errors introduced. The intentional errors composed of prescribed dose (±2 to ±6%) and position shifting in X-axis and Y-axis (±1 to ±5mm). After measurement, gamma pass between original and modified plans were compared. The average gamma pass for original H&N and prostate plans were 98.3% and 100% for MapCHECK2 and 95.9% and 99.8% for portal dosimetry, respectively. In H&N plan, MapCHECK2 can detect position shift errors starting from 3mm while portal dosimetry can detect errors started from 2mm. Both devices showed similar sensitivity in detection of position shift error in prostate plan. For H&N plan, MapCHECK2 can detect dose errors starting at ±4%, whereas portal dosimetry can detect from ±2%. For prostate plan, both devices can identify dose errors starting from ±4%. Sensitivity of error detection depends on type of errors and plan complexity.
Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.
Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E
2012-10-01
The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p < 0.0001). The predominant error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.
Patient safety awareness among Undergraduate Medical Students in Pakistani Medical School.
Kamran, Rizwana; Bari, Attia; Khan, Rehan Ahmed; Al-Eraky, Mohamed
2018-01-01
To measure the level of awareness of patient safety among undergraduate medical students in Pakistani Medical School and to find the difference with respect to gender and prior experience with medical error. This cross-sectional study was conducted at the University of Lahore (UOL), Pakistan from January to March 2017, and comprised final year medical students. Data was collected using a questionnaire 'APSQ- III' on 7 point Likert scale. Eight questions were reverse coded. Survey was anonymous. SPSS package 20 was used for statistical analysis. Questionnaire was filled by 122 students, with 81% response rate. The best score 6.17 was given for the 'team functioning', followed by 6.04 for 'long working hours as a cause of medical error'. The domains regarding involvement of patient, confidence to report medical errors and role of training and learning on patient safety scored high in the agreed range of >5. Reverse coded questions about 'professional incompetence as an error cause' and 'disclosure of errors' showed negative perception. No significant differences of perceptions were found with respect to gender and prior experience with medical error (p= >0.05). Undergraduate medical students at UOL had a positive attitude towards patient safety. However, there were misconceptions about causes of medical errors and error disclosure among students and patient safety education needs to be incorporated in medical curriculum of Pakistan.
Ferreira, Carolina Justus Buhrer; Plodek, Caroline Koga; Soares, Franciny Kossemba; Andrade, Rayza Assis de; Teleginski, Fernanda; Rocha, Maria Dagmar da
2016-01-01
to analyze the impact of guidelines regarding errors in medications prescribed for administration through enteral tubes. quantitative study, in three phases, undertaken in internal medicine, neurology and an intensive care unit in a general teaching hospital. In Phase 1, the following was undertaken: a protocol for dilution and unit-dose repackaging and administration for 294 medications via enteral tubes; a decision flowchart; operational-standard procedures for dilution and unit-dose repackaging of oral pharmaceutical forms and for administration of medications through enteral tubes. In phase 2, errors in 872 medications prescribed through enteral tubes, in 293 prescriptions for patients receiving inpatient treatment between March and June, were investigated. This was followed by training of the teams in relation to the guidelines established. In Phase 3, pharmaceutical errors and interventions in 945 medications prescribed through enteral tubes, in 292 prescriptions of patients receiving inpatient treatment between August and September, were investigated prospectively. The data collected, in a structured questionnaire, were compiled in the Microsoft Office Excel(r) program, and frequencies were calculated. 786 errors were observed, 63.9% (502) in Phase 2, and 36.1% (284) in Phase 3. In Phase 3, a reduction was ascertained in the frequency of prescription of medications delivered via enteral tubes, medications which were contraindicated, and those for which information was not available. guidelines and pharmaceutical interventions were determined in the prevention of errors involving medications delivered through enteral tubes. analisar o impacto de diretrizes sobre erros em medicamentos prescritos para administração via sondas enterais. estudo quantitativo, em três fases, realizado em clínica médica, neurologia e unidade de terapia intensiva de hospital geral universitário. Na Fase 1 elaborou-se: protocolo de diluição, unitarização - transformação e administração para 294 medicamentos via sondas enterais; fluxograma decisório; procedimentos operacionais-padrão de diluição e unitarização de formas farmacêuticas orais e de administração de medicamentos via sondas enterais. Na Fase 2 investigou-se, retrospectivamente, erros em 872 medicamentos prescritos via sondas enterais, em 293 prescrições de pacientes internados de março a junho. Seguiu-se capacitação das equipes sobre diretrizes estabelecidas. Na Fase 3 investigou-se, prospectivamente, erros e intervenções farmacêuticas em 945 medicamentos prescritos via sondas enterais, em 292 prescrições de pacientes internados de agosto a setembro. Dados coletados, em formulário estruturado, foram compilados no programa Microsoft Office Excel(r) e calculadas as frequências. foram observados 786 erros, 63,9% (502) na Fase 2 e 36,1% (284) na Fase 3. Na Fase 3 verificou-se redução na frequência de prescrição de medicamentos, via sondas enterais, contraindicados e sem informações disponíveis. diretrizes e intervenções farmacêuticas foram determinantes na prevenção dos erros de medicamentos via sondas enterais. analizar el impacto de directrices sobre errores en medicamentos prescritos para administración vía sondas enterales. estudio cuantitativo, en tres fases, realizado en una clínica médica-neurología y en unidad de terapia intensiva de un hospital general universitario. En la Fase 1 se elaboró: protocolo de dilución, reenvasado - transformación y administración para 294 medicamentos vía sondas enterales; diagrama de flujo de decisión; procedimientos operacionales estándar de dilución y reenvasado - transformación de formas farmacéuticas orales y de administración de medicamentos vía sondas enterales. En la Fase 2 se investigó, retrospectivamente, errores en 872 medicamentos prescritos vía sondas enterales, en 293 prescripciones de pacientes internados de marzo a junio. La continuación, capacitación de los equipos sobre directrices establecidas. En la Fase 3 se investigó, prospectivamente, errores e intervenciones farmacéuticas en 945 medicamentos prescritos vía sondas enterales, en 292 prescripciones de pacientes internados de agosto a septiembre. Datos fueron colectados en un formulario estructurado, compilados en el programa Microsoft Office Excel(r) y se calcularon las frecuencias. se observaron 786 errores, 63,9% (502) en la Fase 2 y 36,1% (284) en la Fase 3. En la Fase 3 se verificó una reducción en la frecuencia de prescripción de medicamentos, vía sondas enterales, contraindicados y sin informaciones disponibles. las directrices e intervenciones farmacéuticas fueron determinantes en la prevención de los errores de medicamentos vía sondas enterales.
TU-G-BRD-08: In-Vivo EPID Dosimetry: Quantifying the Detectability of Four Classes of Errors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ford, E; Phillips, M; Bojechko, C
Purpose: EPID dosimetry is an emerging method for treatment verification and QA. Given that the in-vivo EPID technique is in clinical use at some centers, we investigate the sensitivity and specificity for detecting different classes of errors. We assess the impact of these errors using dose volume histogram endpoints. Though data exist for EPID dosimetry performed pre-treatment, this is the first study quantifying its effectiveness when used during patient treatment (in-vivo). Methods: We analyzed 17 patients; EPID images of the exit dose were acquired and used to reconstruct the planar dose at isocenter. This dose was compared to the TPSmore » dose using a 3%/3mm gamma criteria. To simulate errors, modifications were made to treatment plans using four possible classes of error: 1) patient misalignment, 2) changes in patient body habitus, 3) machine output changes and 4) MLC misalignments. Each error was applied with varying magnitudes. To assess the detectability of the error, the area under a ROC curve (AUC) was analyzed. The AUC was compared to changes in D99 of the PTV introduced by the simulated error. Results: For systematic changes in the MLC leaves, changes in the machine output and patient habitus, the AUC varied from 0.78–0.97 scaling with the magnitude of the error. The optimal gamma threshold as determined by the ROC curve varied between 84–92%. There was little diagnostic power in detecting random MLC leaf errors and patient shifts (AUC 0.52–0.74). Some errors with weak detectability had large changes in D99. Conclusion: These data demonstrate the ability of EPID-based in-vivo dosimetry in detecting variations in patient habitus and errors related to machine parameters such as systematic MLC misalignments and machine output changes. There was no correlation found between the detectability of the error using the gamma pass rate, ROC analysis and the impact on the dose volume histogram. Funded by grant R18HS022244 from AHRQ.« less
Ammari, Maha Al; Sultana, Khizra; Yunus, Faisal; Ghobain, Mohammed Al; Halwan, Shatha M. Al
2016-01-01
Objectives: To assess the proportion of critical errors committed while demonstrating the inhaler technique in hospitalized patients diagnosed with asthma and chronic obstructive pulmonary disease (COPD). Methods: This cross-sectional observational study was conducted in 47 asthmatic and COPD patients using inhaler devices. The study took place at King Abdulaziz Medical City, Riyadh, Saudi Arabia between September and December 2013. Two pharmacists independently assessed inhaler technique with a validated checklist. Results: Seventy percent of patients made at least one critical error while demonstrating their inhaler technique, and the mean number of critical errors per patient was 1.6. Most patients used metered dose inhaler (MDI), and 73% of MDI users and 92% of dry powder inhaler users committed at least one critical error. Conclusion: Inhaler technique in hospitalized Saudi patients was inadequate. Health care professionals should understand the importance of reassessing and educating patients on a regular basis for inhaler technique, recommend the use of a spacer when needed, and regularly assess and update their own inhaler technique skills. PMID:27146622
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, S; Mazur, T; Li, H
Purpose: The aim of this paper was to demonstrate the feasibility and creditability of computing and verifying 3D fluencies to assure IMRT and VMAT treatment deliveries, by correlating the passing rates of the 3D fluence-based QA (P(ά)) to the passing rates of 2D dose measurementbased QA (P(Dm)). Methods: 3D volumetric primary fluencies are calculated by forward-projecting the beam apertures and modulated by beam MU values at all gantry angles. We first introduce simulated machine parameter errors (MU, MLC positions, jaw, gantry and collimator) to the plan. Using passing rates of voxel intensity differences (P(Ir)) and 3D gamma analysis (P(γ)), calculatedmore » 3D fluencies, calculated 3D delivered dose, and measured 2D planar dose in phantom from the original plan are then compared with those from corresponding plans with errors, respectively. The correlations of these three groups of resultant passing rates, i.e. 3D fluence-based QA (P(ά,Ir) and P(ά,γ)), calculated 3D dose (P(Dc,Ir) and P(Dc,γ)), and 2D dose measurement-based QA (P(Dm,Ir) and P(Dm,γ)), will be investigated. Results: 20 treatment plans with 5 different types of errors were tested. Spearman’s correlations were found between P(ά,Ir) and P(Dc,Ir), and also between P(ά,γ) and P(Dc,γ), with averaged p-value 0.037, 0.065, and averaged correlation coefficient ρ-value 0.942, 0.871 respectively. Using Matrixx QA for IMRT plans, Spearman’s correlations were also obtained between P(ά,Ir) and P(Dm,Ir) and also between P(ά,γ) and P(Dm,γ), with p-value being 0.048, 0.071 and ρ-value being 0.897, 0.779 respectively. Conclusion: The demonstrated correlations improve the creditability of using 3D fluence-based QA for assuring treatment deliveries for IMRT/VMAT plans. Together with advantages of high detection sensitivity and better visualization of machine parameter errors, this study further demonstrates the accuracy and feasibility of 3D fluence based-QA in pre-treatment QA and daily QA. Research reported in this study is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.« less
Being a Victim of Medical Error in Brazil: An (Un)Real Dilemma
Mendonça, Vitor Silva; Custódio, Eda Marconi
2016-01-01
Medical error stems from inadequate professional conduct that is capable of producing harm to life or exacerbating the health of another, whether through act or omission. This situation has become increasingly common in Brazil and worldwide. In this study, the aim was to understand what being the victim of medical error is like and to investigate the circumstances imposed on this condition of victims in Brazil. A semi-structured interview was conducted with twelve people who had gone through situations of medical error in their lives, creating a space for narratives of their experiences and deep reflection on the phenomenon. The concept of medical error has a negative connotation, often being associated with the incompetence of a medical professional. Medical error in Brazil is demonstrated by low-quality professional performance and represents the current reality of the country because of the common lack of respect and consideration for patients. Victims often remark on their loss of identity, as their social functions have been interrupted and they do not expect to regain such. It was found, however, little assumption of error in the involved doctors’ discourses and attitudes, which felt a need to judge the medical conduct in an attempt to assert their rights. Medical error in Brazil presents a punitive character and is little discussed in medical and scientific circles. The stigma of medical error is closely connected to the value and cultural judgments of the country, making it difficult to accept, both by victims and professionals. PMID:27403461
Bubalo, Joseph; Warden, Bruce A; Wiegel, Joshua J; Nishida, Tess; Handel, Evelyn; Svoboda, Leanne M; Nguyen, Lam; Edillo, P Neil
2014-12-01
Medical errors, in particular medication errors, continue to be a troublesome factor in the delivery of safe and effective patient care. Antineoplastic agents represent a group of medications highly susceptible to medication errors due to their complex regimens and narrow therapeutic indices. As the majority of these medication errors are frequently associated with breakdowns in poorly defined systems, developing technologies and evolving workflows seem to be a logical approach to provide added safeguards against medication errors. This article will review both the pros and cons of today's technologies and their ability to simplify the medication use process, reduce medication errors, improve documentation, improve healthcare costs and increase provider efficiency as relates to the use of antineoplastic therapy throughout the medication use process. Several technologies, mainly computerized provider order entry (CPOE), barcode medication administration (BCMA), smart pumps, electronic medication administration record (eMAR), and telepharmacy, have been well described and proven to reduce medication errors, improve adherence to quality metrics, and/or improve healthcare costs in a broad scope of patients. The utilization of these technologies during antineoplastic therapy is weak at best and lacking for most. Specific to the antineoplastic medication use system, the only technology with data to adequately support a claim of reduced medication errors is CPOE. In addition to the benefits these technologies can provide, it is also important to recognize their potential to induce new types of errors and inefficiencies which can negatively impact patient care. The utilization of technology reduces but does not eliminate the potential for error. The evidence base to support technology in preventing medication errors is limited in general but even more deficient in the realm of antineoplastic therapy. Though CPOE has the best evidence to support its use in the antineoplastic population, benefit from many other technologies may have to be inferred based on data from other patient populations. As health systems begin to widely adopt and implement new technologies it is important to critically assess their effectiveness in improving patient safety. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Van de Vreede, Melita; McGrath, Anne; de Clifford, Jan
2018-05-14
Objective. The aim of the present study was to identify and quantify medication errors reportedly related to electronic medication management systems (eMMS) and those considered likely to occur more frequently with eMMS. This included developing a new classification system relevant to eMMS errors. Methods. Eight Victorian hospitals with eMMS participated in a retrospective audit of reported medication incidents from their incident reporting databases between May and July 2014. Site-appointed project officers submitted deidentified incidents they deemed new or likely to occur more frequently due to eMMS, together with the Incident Severity Rating (ISR). The authors reviewed and classified incidents. Results. There were 5826 medication-related incidents reported. In total, 93 (47 prescribing errors, 46 administration errors) were identified as new or potentially related to eMMS. Only one ISR2 (moderate) and no ISR1 (severe or death) errors were reported, so harm to patients in this 3-month period was minimal. The most commonly reported error types were 'human factors' and 'unfamiliarity or training' (70%) and 'cross-encounter or hybrid system errors' (22%). Conclusions. Although the results suggest that the errors reported were of low severity, organisations must remain vigilant to the risk of new errors and avoid the assumption that eMMS is the panacea to all medication error issues. What is known about the topic? eMMS have been shown to reduce some types of medication errors, but it has been reported that some new medication errors have been identified and some are likely to occur more frequently with eMMS. There are few published Australian studies that have reported on medication error types that are likely to occur more frequently with eMMS in more than one organisation and that include administration and prescribing errors. What does this paper add? This paper includes a new simple classification system for eMMS that is useful and outlines the most commonly reported incident types and can inform organisations and vendors on possible eMMS improvements. The paper suggests a new classification system for eMMS medication errors. What are the implications for practitioners? The results of the present study will highlight to organisations the need for ongoing review of system design, refinement of workflow issues, staff education and training and reporting and monitoring of errors.
Cochran, Gary L; Barrett, Ryan S; Horn, Susan D
2016-08-01
The role of pharmacist transcription, onsite pharmacist dispensing, use of automated dispensing cabinets (ADCs), nurse-nurse double checks, or barcode-assisted medication administration (BCMA) in reducing medication error rates in critical access hospitals (CAHs) was evaluated. Investigators used the practice-based evidence methodology to identify predictors of medication errors in 12 Nebraska CAHs. Detailed information about each medication administered was recorded through direct observation. Errors were identified by comparing the observed medication administered with the physician's order. Chi-square analysis and Fisher's exact test were used to measure differences between groups of medication-dispensing procedures. Nurses observed 6497 medications being administered to 1374 patients. The overall error rate was 1.2%. The transcription error rates for orders transcribed by an onsite pharmacist were slightly lower than for orders transcribed by a telepharmacy service (0.10% and 0.33%, respectively). Fewer dispensing errors occurred when medications were dispensed by an onsite pharmacist versus any other method of medication acquisition (0.10% versus 0.44%, p = 0.0085). The rates of dispensing errors for medications that were retrieved from a single-cell ADC (0.19%), a multicell ADC (0.45%), or a drug closet or general supply (0.77%) did not differ significantly. BCMA was associated with a higher proportion of dispensing and administration errors intercepted before reaching the patient (66.7%) compared with either manual double checks (10%) or no BCMA or double check (30.4%) of the medication before administration (p = 0.0167). Onsite pharmacist dispensing and BCMA were associated with fewer medication errors and are important components of a medication safety strategy in CAHs. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Clarification of terminology in medication errors: definitions and classification.
Ferner, Robin E; Aronson, Jeffrey K
2006-01-01
We have previously described and analysed some terms that are used in drug safety and have proposed definitions. Here we discuss and define terms that are used in the field of medication errors, particularly terms that are sometimes misunderstood or misused. We also discuss the classification of medication errors. A medication error is a failure in the treatment process that leads to, or has the potential to lead to, harm to the patient. Errors can be classified according to whether they are mistakes, slips, or lapses. Mistakes are errors in the planning of an action. They can be knowledge based or rule based. Slips and lapses are errors in carrying out an action - a slip through an erroneous performance and a lapse through an erroneous memory. Classification of medication errors is important because the probabilities of errors of different classes are different, as are the potential remedies.
Hall, William L; Larkin, Gregory L; Trujillo, Mauricio J; Hinds, Jackie L; Delaney, Kathleen A
2004-10-01
To examine biases in weight estimation by Emergency Department (ED) providers and patients, a convenience sample of ED providers (faculty, residents, interns, nurses, medical students, paramedics) and patients was studied. Providers (n = 33), blinded to study hypothesis and patient data, estimated their own weight as well as the weight of 11-20 patients each. An independent sample of patients (n = 95) was used to assess biases in patients' estimation of their own weight. Data are represented as over, under, or within +/- 5 kg, the dose tolerance standard for thrombolytics. Logistic regression analysis revealed that patients are almost nine times more likely to accurately estimate their own weight than providers; yet 22% of patients were unable to estimate their own weight within 5 kg. Of all providers, paramedics were significantly worse estimators of patient weight than other providers. Providers were no better at guessing their own weight than were patients. Though there was no systematic estimate bias by weight, experience level (except paramedic), or gender for providers, those providers under 30 years of age were significantly better estimators of patient weight than older providers. Although patient gender did not create a bias in provider estimation accuracy, providers were more likely to underestimate women's weights than men's. In conclusion, patient self-estimates of weight are significantly better than estimates by providers. Inaccurate estimates by both groups could potentially contribute to medication dosing errors in the ED.
McComas, Jeffery; Riingen, Michelle; Chae Kim, Son
2014-12-01
The study aims were to evaluate the impact of electronic medication administration record implementation on medication administration efficiency and occurrence of medication errors as well as to identify the predictors of medication administration efficiency in an acute care setting. A prospective, observational study utilizing time-and-motion technique was conducted before and after electronic medication administration record implementation in November 2011. A total of 156 cases of medication administration activities (78 pre- and 78 post-electronic medication administration record) involving 38 nurses were observed at the point of care. A separate retrospective review of the hospital Midas+ medication error database was also performed to collect the rates and origin of medication errors for 6 months before and after electronic medication administration record implementation. The mean medication administration time actually increased from 11.3 to 14.4 minutes post-electronic medication administration record (P = .039). In a multivariate analysis, electronic medication administration record was not a predictor of medication administration time, but the distractions/interruptions during medication administration process were significant predictors. The mean hospital-wide medication errors significantly decreased from 11.0 to 5.3 events per month post-electronic medication administration record (P = .034). Although no improvement in medication administration efficiency was observed, electronic medication administration record improved the quality of care with a significant decrease in medication errors.
Thyroid cancer following scalp irradiation: a reanalysis accounting for uncertainty in dosimetry.
Schafer, D W; Lubin, J H; Ron, E; Stovall, M; Carroll, R J
2001-09-01
In the 1940s and 1950s, over 20,000 children in Israel were treated for tinea capitis (scalp ringworm) by irradiation to induce epilation. Follow-up studies showed that the radiation exposure was associated with the development of malignant thyroid neoplasms. Despite this clear evidence of an effect, the magnitude of the dose-response relationship is much less clear because of probable errors in individual estimates of dose to the thyroid gland. Such errors have the potential to bias dose-response estimation, a potential that was not widely appreciated at the time of the original analyses. We revisit this issue, describing in detail how errors in dosimetry might occur, and we develop a new dose-response model that takes the uncertainties of the dosimetry into account. Our model for the uncertainty in dosimetry is a complex and new variant of the classical multiplicative Berkson error model, having components of classical multiplicative measurement error as well as missing data. Analysis of the tinea capitis data suggests that measurement error in the dosimetry has only a negligible effect on dose-response estimation and inference as well as on the modifying effect of age at exposure.
Outcomes of a Failure Mode and Effects Analysis for medication errors in pediatric anesthesia.
Martin, Lizabeth D; Grigg, Eliot B; Verma, Shilpa; Latham, Gregory J; Rampersad, Sally E; Martin, Lynn D
2017-06-01
The Institute of Medicine has called for development of strategies to prevent medication errors, which are one important cause of preventable harm. Although the field of anesthesiology is considered a leader in patient safety, recent data suggest high medication error rates in anesthesia practice. Unfortunately, few error prevention strategies for anesthesia providers have been implemented. Using Toyota Production System quality improvement methodology, a multidisciplinary team observed 133 h of medication practice in the operating room at a tertiary care freestanding children's hospital. A failure mode and effects analysis was conducted to systematically deconstruct and evaluate each medication handling process step and score possible failure modes to quantify areas of risk. A bundle of five targeted countermeasures were identified and implemented over 12 months. Improvements in syringe labeling (73 to 96%), standardization of medication organization in the anesthesia workspace (0 to 100%), and two-provider infusion checks (23 to 59%) were observed. Medication error reporting improved during the project and was subsequently maintained. After intervention, the median medication error rate decreased from 1.56 to 0.95 per 1000 anesthetics. The frequency of medication error harm events reaching the patient also decreased. Systematic evaluation and standardization of medication handling processes by anesthesia providers in the operating room can decrease medication errors and improve patient safety. © 2017 John Wiley & Sons Ltd.
A continuous quality improvement project to reduce medication error in the emergency department.
Lee, Sara Bc; Lee, Larry Ly; Yeung, Richard Sd; Chan, Jimmy Ts
2013-01-01
Medication errors are a common source of adverse healthcare incidents particularly in the emergency department (ED) that has a number of factors that make it prone to medication errors. This project aims to reduce medication errors and improve the health and economic outcomes of clinical care in Hong Kong ED. In 2009, a task group was formed to identify problems that potentially endanger medication safety and developed strategies to eliminate these problems. Responsible officers were assigned to look after seven error-prone areas. Strategies were proposed, discussed, endorsed and promulgated to eliminate the problems identified. A reduction of medication incidents (MI) from 16 to 6 was achieved before and after the improvement work. This project successfully established a concrete organizational structure to safeguard error-prone areas of medication safety in a sustainable manner.
Lee, Eunjoo
2016-09-01
This study compared registered nurses' perceptions of safety climate and attitude toward medication error reporting before and after completing a hospital accreditation program. Medication errors are the most prevalent adverse events threatening patient safety; reducing underreporting of medication errors significantly improves patient safety. Safety climate in hospitals may affect medication error reporting. This study employed a longitudinal, descriptive design. Data were collected using questionnaires. A tertiary acute hospital in South Korea undergoing a hospital accreditation program. Nurses, pre- and post-accreditation (217 and 373); response rate: 58% and 87%, respectively. Hospital accreditation program. Perceived safety climate and attitude toward medication error reporting. The level of safety climate and attitude toward medication error reporting increased significantly following accreditation; however, measures of institutional leadership and management did not improve significantly. Participants' perception of safety climate was positively correlated with their attitude toward medication error reporting; this correlation strengthened following completion of the program. Improving hospitals' safety climate increased nurses' medication error reporting; interventions that help hospital administration and managers to provide more supportive leadership may facilitate safety climate improvement. Hospitals and their units should develop more friendly and intimate working environments that remove nurses' fear of penalties. Administration and managers should support nurses who report their own errors. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Heuristic errors in clinical reasoning.
Rylander, Melanie; Guerrasio, Jeannette
2016-08-01
Errors in clinical reasoning contribute to patient morbidity and mortality. The purpose of this study was to determine the types of heuristic errors made by third-year medical students and first-year residents. This study surveyed approximately 150 clinical educators inquiring about the types of heuristic errors they observed in third-year medical students and first-year residents. Anchoring and premature closure were the two most common errors observed amongst third-year medical students and first-year residents. There was no difference in the types of errors observed in the two groups. Errors in clinical reasoning contribute to patient morbidity and mortality Clinical educators perceived that both third-year medical students and first-year residents committed similar heuristic errors, implying that additional medical knowledge and clinical experience do not affect the types of heuristic errors made. Further work is needed to help identify methods that can be used to reduce heuristic errors early in a clinician's education. © 2015 John Wiley & Sons Ltd.
Using incident reports to inform the prevention of medication administration errors.
Härkänen, Marja; Saano, Susanna; Vehviläinen-Julkunen, Katri
2017-11-01
To describe ways of preventing medication administration errors based on reporters' views expressed in medication administration incident reports. Medication administration errors are very common, and nurses play important roles in committing and in preventing such errors. Thus far, incident reporters' perceptions of how to prevent medication administration errors have rarely been analysed. This is a qualitative, descriptive study using an inductive content analysis of the incident reports related to medication administration errors (n = 1012). These free-text descriptions include reporters' views on preventing the reoccurrence of medication administration errors. The data were collected from two hospitals in Finland and pertain to incidents that were reported between 1 January 2013 and 31 December 2014. Reporters' views on preventing medication administration errors were divided into three main categories related to individuals (health professionals), teams and organisations. The following categories related to individuals in preventing medication administration errors were identified: (1) accuracy and preciseness; (2) verification; and (3) following the guidelines, responsibility and attitude towards work. The team categories were as follows: (1) distribution of work; (2) flow of information and cooperation; and (3) documenting and marking the drug information. The categories related to organisation were as follows: (1) work environment; (2) resources; (3) training; (4) guidelines; and (5) development of the work. Health professionals should administer medication with a high moral awareness and an attempt to concentrate on the task. Nonetheless, the system should support health professionals by providing a reasonable work environment and encouraging collaboration among the providers to facilitate the safe administration of medication. Although there are numerous approaches to supporting medication safety, approaches that support the ability of individual health professionals to manage daily medications should be prioritised. © 2017 John Wiley & Sons Ltd.
Fischer, Melissa A; Mazor, Kathleen M; Baril, Joann; Alper, Eric; DeMarco, Deborah; Pugnaire, Michele
2006-01-01
CONTEXT Trainees are exposed to medical errors throughout medical school and residency. Little is known about what facilitates and limits learning from these experiences. OBJECTIVE To identify major factors and areas of tension in trainees' learning from medical errors. DESIGN, SETTING, AND PARTICIPANTS Structured telephone interviews with 59 trainees (medical students and residents) from 1 academic medical center. Five authors reviewed transcripts of audiotaped interviews using content analysis. RESULTS Trainees were aware that medical errors occur from early in medical school. Many had an intense emotional response to the idea of committing errors in patient care. Students and residents noted variation and conflict in institutional recommendations and individual actions. Many expressed role confusion regarding whether and how to initiate discussion after errors occurred. Some noted the conflict between reporting errors to seniors who were responsible for their evaluation. Learners requested more open discussion of actual errors and faculty disclosure. No students or residents felt that they learned better from near misses than from actual errors, and many believed that they learned the most when harm was caused. CONCLUSIONS Trainees are aware of medical errors, but remaining tensions may limit learning. Institutions can immediately address variability in faculty response and local culture by disseminating clear, accessible algorithms to guide behavior when errors occur. Educators should develop longitudinal curricula that integrate actual cases and faculty disclosure. Future multi-institutional work should focus on identified themes such as teaching and learning in emotionally charged situations, learning from errors and near misses and balance between individual and systems responsibility. PMID:16704381
Automated drug dispensing system reduces medication errors in an intensive care setting.
Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick
2010-12-01
We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; p<.05); however, no significant difference was observed before automated dispensing system implementation (20.4% and 19.3%, respectively; not significant). Before-and-after comparisons in the study unit also showed a significantly reduced percentage of total opportunities for error (20.4% and 13.5%; p<.01). An analysis of detailed opportunities for error showed a significant impact of the automated dispensing system in reducing preparation errors (p<.05). Most errors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.
NASA Astrophysics Data System (ADS)
Sánchez-Doblado, Francisco; Capote, Roberto; Leal, Antonio; Roselló, Joan V.; Lagares, Juan I.; Arráns, Rafael; Hartmann, Günther H.
2005-03-01
Intensity modulated radiotherapy (IMRT) has become a treatment of choice in many oncological institutions. Small fields or beamlets with sizes of 1 to 5 cm2 are now routinely used in IMRT delivery. Therefore small ionization chambers (IC) with sensitive volumes <=0.1 cm3are generally used for dose verification of an IMRT treatment. The measurement conditions during verification may be quite different from reference conditions normally encountered in clinical beam calibration, so dosimetry of these narrow photon beams pertains to the so-called non-reference conditions for beam calibration. This work aims at estimating the error made when measuring the organ at risk's (OAR) absolute dose by a micro ion chamber (μIC) in a typical IMRT treatment. The dose error comes from the assumption that the dosimetric parameters determining the absolute dose are the same as for the reference conditions. We have selected two clinical cases, treated by IMRT, for our dose error evaluations. Detailed geometrical simulation of the μIC and the dose verification set-up was performed. The Monte Carlo (MC) simulation allows us to calculate the dose measured by the chamber as a dose averaged over the air cavity within the ion-chamber active volume (Dair). The absorbed dose to water (Dwater) is derived as the dose deposited inside the same volume, in the same geometrical position, filled and surrounded by water in the absence of the ion chamber. Therefore, the Dwater/Dair dose ratio is the MC estimator of the total correction factor needed to convert the absorbed dose in air into the absorbed dose in water. The dose ratio was calculated for the μIC located at the isocentre within the OARs for both clinical cases. The clinical impact of the calculated dose error was found to be negligible for the studied IMRT treatments.
Addressing Medical Errors in Hand Surgery
Johnson, Shepard P.; Adkinson, Joshua M.; Chung, Kevin C.
2014-01-01
Influential think-tank such as the Institute of Medicine has raised awareness about the implications of medical errors. In response, organizations, medical societies, and institutions have initiated programs to decrease the incidence and effects of these errors. Surgeons deal with the direct implications of adverse events involving patients. In addition to managing the physical consequences, they are confronted with ethical and social issues when caring for a harmed patient. Although there is considerable effort to implement system-wide changes, there is little guidance for hand surgeons on how to address medical errors. Admitting an error is difficult, but a transparent environment where patients are notified of errors and offered consolation and compensation is essential to maintain trust. Further, equipping hand surgeons with a guide for addressing medical errors will promote compassionate patient interaction, help identify system failures, provide learning points for safety improvement, and demonstrate a commitment to ethically responsible medical care. PMID:25154576
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Perry B.; Geyer, Amy; Borrego, David
Purpose: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions. Methods: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific andmore » patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference. Results: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections. Conclusions: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences. For large patients, difference in soft tissue attenuation can be large. In these cases, patient-phantom matching proves most effective as differences in soft tissue attenuation are mitigated. With increasing obesity rates, overweight patients will continue to make up a growing fraction of all patients undergoing medical imaging. Thus, having phantoms that better represent this population represents a considerable improvement over previous methods. In response to this study, additional phantoms representing heavier weight percentiles will be added to the UFHADM and UFHADF patient-dependent series.« less
Baumstark, Annette; Jendrike, Nina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido
2017-10-01
Self-monitoring of blood glucose (BG) is an essential part of diabetes therapy. Accurate and reliable results from BG monitoring systems (BGMS) are important especially when they are used to calculate insulin doses. This study aimed at assessing system accuracy of BGMS and possibly related insulin dosing errors. System accuracy of six different BGMS (Accu-Chek ® Aviva Nano, Accu-Chek Mobile, Accu-Chek Performa Nano, CONTOUR ® NEXT LINK 2.4, FreeStyle Lite, OneTouch ® Verio ® IQ) was assessed in comparison to a glucose oxidase and a hexokinase method. Study procedures and analysis were based on ISO 15197:2013/EN ISO 15197:2015, clause 6.3. In addition, insulin dosing error was modeled. In the comparison against the glucose oxidase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 14.3%/4.3%/0.3% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U and missing the modeled target by 20 mg/dL/40 mg/dL/60 mg/dL, respectively. Compared against the hexokinase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 25.0%/10.5%/3.2% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U, respectively. Differences in system accuracy were found, even among BGMS that fulfilled the minimum system accuracy criteria of ISO 15197:2013. In the error model, considerable insulin dosing errors resulted for some of the investigated systems. Diabetes patients on insulin therapy should be able to rely on their BGMS' readings; therefore, they require highly accurate BGMS, in particular, when making therapeutic decisions.
[Validation of a method for notifying and monitoring medication errors in pediatrics].
Guerrero-Aznar, M D; Jiménez-Mesa, E; Cotrina-Luque, J; Villalba-Moreno, A; Cumplido-Corbacho, R; Fernández-Fernández, L
2014-12-01
To analyze the impact of a multidisciplinary and decentralized safety committee in the pediatric management unit, and the joint implementation of a computing network application for reporting medication errors, monitoring the follow-up of the errors, and an analysis of the improvements introduced. An observational, descriptive, cross-sectional, pre-post intervention study was performed. An analysis was made of medication errors reported to the central safety committee in the twelve months prior to introduction, and those reported to the decentralized safety committee in the management unit in the nine months after implementation, using the computer application, and the strategies generated by the analysis of reported errors. Number of reported errors/10,000 days of stay, number of reported errors with harm per 10,000 days of stay, types of error, categories based on severity, stage of the process, and groups involved in the notification of medication errors. Reported medication errors increased 4.6 -fold, from 7.6 notifications of medication errors per 10,000 days of stay in the pre-intervention period to 36 in the post-intervention, rate ratio 0.21 (95% CI; 0.11-0.39) (P<.001). The medication errors with harm or requiring monitoring reported per 10,000 days of stay, was virtually unchanged from one period to the other ratio rate 0,77 (95% IC; 0,31-1,91) (P>.05). The notification of potential errors or errors without harm per 10,000 days of stay increased 17.4-fold (rate ratio 0.005., 95% CI; 0.001-0.026, P<.001). The increase in medication errors notified in the post-intervention period is a reflection of an increase in the motivation of health professionals to report errors through this new method. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Kowal, Mikael A; van Steenbergen, Henk; Colzato, Lorenza S; Hazekamp, Arno; van der Wee, Nic J A; Manai, Meriem; Durieux, Jeffrey; Hommel, Bernhard
2015-11-01
Cannabis has been suggested to impair the capacity to recognize discrepancies between expected and executed actions. However, there is a lack of conclusive evidence regarding the acute impact of cannabis on the neural correlates of error monitoring. In order to contribute to the available knowledge, we used a randomized, double-blind, between-groups design to investigate the impact of administration of a low (5.5 mg THC) or high (22 mg THC) dose of vaporized cannabis vs. placebo on the amplitudes of the error-related negativity (ERN) and error positivity (Pe) in the context of the Flanker task, in a group of frequent cannabis users (required to use cannabis minimally 4 times a week, for at least 2 years). Subjects in the high dose group (n=18) demonstrated a significantly diminished ERN in comparison to the placebo condition (n=19), whereas a reduced Pe amplitude was observed in both the high and low dose (n=18) conditions, as compared to placebo. The results suggest that a high dose of cannabis may affect the neural correlates of both the conscious (late), as well as the initial automatic processes involved in error monitoring, while a low dose of cannabis might impact only the conscious (late) processing of errors. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.
Automated estimation of abdominal effective diameter for body size normalization of CT dose.
Cheng, Phillip M
2013-06-01
Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.
Giraldo, Priscila; Sato, Luke; Martínez-Sánchez, Jose M; Comas, Mercè; Dwyer, Kathy; Sala, Maria; Castells, Xavier
2016-01-01
Objectives To evaluate and compare the characteristics of court verdicts on medical errors allegedly harming patients in Spain and Massachusetts from 2002 to 2012. Design, setting and participants We reviewed 1041 closed court verdicts obtained from data on litigation in the Thomson Reuters Aranzadi Westlaw databases in Spain (Europe), and 370 closed court verdicts obtained from the Controlled Risk and Risk Management Foundation of Harvard Medical Institutions (CRICO/RMF) in Massachusetts (USA). We included closed court verdicts on medical errors. The definition of medical errors was based on that of the Institute of Medicine (USA). We excluded any agreements between parties before a judgement. Results Medical errors were involved in 25.9% of court verdicts in Spain and in 74% of those in Massachusetts. The most frequent cause of medical errors was a diagnosis-related problem (25.1%; 95% CI 20.7% to 31.1% in Spain; 35%; 95% CI 29.4% to 40.7% in Massachusetts). The proportion of medical errors classified as high severity was 34% higher in Spain than in Massachusetts (p=0.001). The most frequent factors contributing to medical errors in Spain were surgical and medical treatment (p=0.001). In Spain, 98.5% of medical errors resulted in compensation awards compared with only 6.9% in Massachusetts. Conclusions This study reveals wide differences in litigation rates and the award of indemnity payments in Spain and Massachusetts; however, common features of both locations are the high rates of diagnosis-related problems and the long time interval until resolution. PMID:27577585
The importance of intra-hospital pharmacovigilance in the detection of medication errors
Villegas, Francisco; Figueroa-Montero, David; Barbero-Becerra, Varenka; Juárez-Hernández, Eva; Uribe, Misael; Chávez-Tapia, Norberto; González-Chon, Octavio
2018-01-01
Hospitalized patients are susceptible to medication errors, which represent between the fourth and the sixth cause of death. The department of intra-hospital pharmacovigilance intervenes in the entire process of medication with the purpose to prevent, repair and assess damages. To analyze medication errors reported by Mexican Fundación Clínica Médica Sur pharmacovigilance system and their impact on patients. Prospective study carried out from 2012 to 2015, where medication prescriptions given to patients were recorded. Owing to heterogeneity, data were described as absolute numbers in a logarithmic scale. 292 932 prescriptions of 56 368 patients were analyzed, and 8.9% of medication errors were identified. The treating physician was responsible of 83.32% of medication errors, residents of 6.71% and interns of 0.09%. No error caused permanent damage or death. This is the pharmacovigilance study with the largest sample size reported. Copyright: © 2018 SecretarÍa de Salud.
The District Nursing Clinical Error Reduction Programme.
McGraw, Caroline; Topping, Claire
2011-01-01
The District Nursing Clinical Error Reduction (DANCER) Programme was initiated in NHS Islington following an increase in the number of reported medication errors. The objectives were to reduce the actual degree of harm and the potential risk of harm associated with medication errors and to maintain the existing positive reporting culture, while robustly addressing performance issues. One hundred medication errors reported in 2007/08 were analysed using a framework that specifies the factors that predispose to adverse medication events in domiciliary care. Various contributory factors were identified and interventions were subsequently developed to address poor drug calculation and medication problem-solving skills and incorrectly transcribed medication administration record charts. Follow up data were obtained at 12 months and two years. The evaluation has shown that although medication errors do still occur, the programme has resulted in a marked shift towards a reduction in the associated actual degree of harm and the potential risk of harm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, X; Gao, H; Schuemann, J
2015-06-15
Purpose: The Monte Carlo (MC) method is a gold standard for dose calculation in radiotherapy. However, it is not a priori clear how many particles need to be simulated to achieve a given dose accuracy. Prior error estimate and stopping criterion are not well established for MC. This work aims to fill this gap. Methods: Due to the statistical nature of MC, our approach is based on one-sample t-test. We design the prior error estimate method based on the t-test, and then use this t-test based error estimate for developing a simulation stopping criterion. The three major components are asmore » follows.First, the source particles are randomized in energy, space and angle, so that the dose deposition from a particle to the voxel is independent and identically distributed (i.i.d.).Second, a sample under consideration in the t-test is the mean value of dose deposition to the voxel by sufficiently large number of source particles. Then according to central limit theorem, the sample as the mean value of i.i.d. variables is normally distributed with the expectation equal to the true deposited dose.Third, the t-test is performed with the null hypothesis that the difference between sample expectation (the same as true deposited dose) and on-the-fly calculated mean sample dose from MC is larger than a given error threshold, in addition to which users have the freedom to specify confidence probability and region of interest in the t-test based stopping criterion. Results: The method is validated for proton dose calculation. The difference between the MC Result based on the t-test prior error estimate and the statistical Result by repeating numerous MC simulations is within 1%. Conclusion: The t-test based prior error estimate and stopping criterion are developed for MC and validated for proton dose calculation. Xiang Hong and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)« less
Medication administration error: magnitude and associated factors among nurses in Ethiopia.
Feleke, Senafikish Amsalu; Mulatu, Muluadam Abebe; Yesmaw, Yeshaneh Seyoum
2015-01-01
The significant impact of medication administration errors affect patients in terms of morbidity, mortality, adverse drug events, and increased length of hospital stay. It also increases costs for clinicians and healthcare systems. Due to this, assessing the magnitude and associated factors of medication administration error has a significant contribution for improving the quality of patient care. The aim of this study was to assess the magnitude and associated factors of medication administration errors among nurses at the Felege Hiwot Referral Hospital inpatient department. A prospective, observation-based, cross-sectional study was conducted from March 24-April 7, 2014 at the Felege Hiwot Referral Hospital inpatient department. A total of 82 nurses were interviewed using a pre-tested structured questionnaire, and observed while administering 360 medications by using a checklist supplemented with a review of medication charts. Data were analyzed by using SPSS version 20 software package and logistic regression was done to identify possible factors associated with medication administration error. The incidence of medication administration error was 199 (56.4 %). The majority (87.5 %) of the medications have documentation error, followed by technique error 263 (73.1 %) and time error 193 (53.6 %). Variables which were significantly associated with medication administration error include nurses between the ages of 18-25 years [Adjusted Odds Ratio (AOR) = 2.9, 95 % CI (1.65,6.38)], 26-30 years [AOR = 2.3, 95 % CI (1.55, 7.26)] and 31-40 years [AOR = 2.1, 95 % CI (1.07, 4.12)], work experience of less than or equal to 10 years [AOR = 1.7, 95 % CI (1.33, 4.99)], nurse to patient ratio of 7-10 [AOR = 1.6, 95 % CI (1.44, 3.19)] and greater than 10 [AOR = 1.5, 95 % CI (1.38, 3.89)], interruption of the respondent at the time of medication administration [AOR = 1.5, 95 % CI (1.14, 3.21)], night shift of medication administration [AOR = 3.1, 95 % CI (1.38, 9.66)] and age of the patients with less than 18 years [AOR = 2.3, 95 % CI (1.17, 4.62)]. In general, medication errors at the administration phase were highly prevalent in Felege Hiwot Referral Hospital. Documentation error is the most dominant type of error observed during the study. Increasing nurses' staffing levels, minimizing distraction and interruptions during medication administration by using no interruptions zones and "No-Talk" signage are recommended to overcome medication administration errors. Retaining experienced nurses from leaving to train and supervise inexperienced nurses with the focus on medication safety, in addition providing convenient sleep hours for nurses would be helpful in ensuring that medication errors don't occur as frequently as observed in this study.
Singer, Alexander; Duarte Fernandez, Roberto
2015-10-28
The Electronic Medical Record (EMR) is becoming increasingly common in health care settings. Research shows that EMRs have the potential to reduce instances of medication errors and improve communication between pharmacists and prescribers; however, more research is required to demonstrate whether this is true. This study aims to determine the effect of a newly implemented EMR system on communication between pharmacists and primary care clinicians. A retrospective chart analysis of primary care EMR data comparing faxed pharmacy communications captured before and after the implementation of an EMR system at an academic family medicine clinic. Communication requests were classified into the following various categories: refill accepted, refill denied, clarification, incorrect dose, interaction, drug insurance/coverage application, new prescription request, supplies request, continued care information, duplicate fax substitution, opioid early release request, confirmation by phone call, and other. The number and percentage of clarification requests, interaction notifications, and incorrect dose notifications were lower after the implementation of the EMR system. The number and percentage of refills accepted and new prescription requests increased after the implementation of the EMR system. The implementation of an EMR in an academic family medicine clinic had a significant effect on the volume of communication between pharmacists and prescribers. The amount of clarification requests and incorrect dosing communications decreased after EMR implementation. This suggests that EMRs improve prescribing safety. The increased amount of refills accepted and new prescription requests post EMR implementation suggests that the EMR is capable of changing prescription patterns.
NASA Astrophysics Data System (ADS)
Fraser, Danielle
In radiation therapy an uncertainty in the delivered dose always exists because anatomic changes are unpredictable and patient specific. Image guided radiation therapy (IGRT) relies on imaging in the treatment room to monitor the tumour and surrounding tissue to ensure their prescribed position in the radiation beam. The goal of this thesis was to determine the dosimetric impact on the misaligned radiation therapy target for three cancer sites due to common setup errors; organ motion, tumour tissue deformation, changes in body habitus, and treatment planning errors. For this purpose, a novel 3D ultrasound system (Restitu, Resonant Medical, Inc.) was used to acquire a reference image of the target in the computed tomography simulation room at the time of treatment planning, to acquire daily images in the treatment room at the time of treatment delivery, and to compare the daily images to the reference image. The measured differences in position and volume between daily and reference geometries were incorporated into Monte Carlo (MC) dose calculations. The EGSnrc (National Research Council, Canada) family of codes was used to model Varian linear accelerators and patient specific beam parameters, as well as to estimate the dose to the target and organs at risk under several different scenarios. After validating the necessity of MC dose calculations in the pelvic region, the impact of interfraction prostate motion, and subsequent patient realignment under the treatment beams, on the delivered dose was investigated. For 32 patients it is demonstrated that using 3D conformal radiation therapy techniques and a 7 mm margin, the prescribed dose to the prostate, rectum, and bladder is recovered within 0.5% of that planned when patient setup is corrected for prostate motion, despite the beams interacting with a new external surface and internal tissue boundaries. In collaboration with the manufacturer, the ultrasound system was adapted from transabdominal imaging to neck imaging. Two case studies of nasopharyngeal cancer are discussed. The deformation of disease-positive cervical lymph nodes was monitored throughout treatment. Node volumes shrunk to 17% of the initial volume, moved up 1.3 cm, and received up to a 12% lower dose than that prescribed. It is shown that difficulties in imaging soft tissue in the neck region are circumvented with ultrasound imaging, and after dosimetric verification it is argued that adaptive replanning may be more beneficial than patient realignment when intensity modulated radiation therapy techniques are used. Some of the largest dose delivery errors were found in external electron beam treatments for breast cancer patients who underwent breast conserving surgery. Inaccuracies in conventional treatment planning resulted in substantial target dose discrepancies of up to 88%. When patient setup errors, interfraction tumour bed motion, and tissue remodeling were considered, inadequate target coverage was exacerbated. This thesis quantifies the dose discrepancy between that prescribed and that delivered. I delve into detail for common IGRT treatment sites, and illuminate problems that have not received much attention for less common IGRT treatment sites.
Medical Errors Reduction Initiative
2005-05-01
working with great success to minimize error. 14. SUBJECT TERMS 15. NUMBER OF PAGES Medical Error, Patient Safety, Personal Data Terminal, Barcodes, 9...AD Award Number: W81XWH-04-1-0536 TITLE: Medical Errors Reduction Initiative PRINCIPAL INVESTIGATOR: Michael L. Mutter 1To CONTRACTING ORGANIZATION...The Valley Hospital Ridgewood, NJ 07450 REPORT DATE: May 2005 TYPE OF REPORT: Annual PREPARED FOR: U.S. Army Medical Research and Materiel Command
SU-F-BRD-05: Robustness of Dose Painting by Numbers in Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montero, A Barragan; Sterpin, E; Lee, J
Purpose: Proton range uncertainties may cause important dose perturbations within the target volume, especially when steep dose gradients are present as in dose painting. The aim of this study is to assess the robustness against setup and range errors for high heterogeneous dose prescriptions (i.e., dose painting by numbers), delivered by proton pencil beam scanning. Methods: An automatic workflow, based on MATLAB functions, was implemented through scripting in RayStation (RaySearch Laboratories). It performs a gradient-based segmentation of the dose painting volume from 18FDG-PET images (GTVPET), and calculates the dose prescription as a linear function of the FDG-uptake value on eachmore » voxel. The workflow was applied to two patients with head and neck cancer. Robustness against setup and range errors of the conventional PTV margin strategy (prescription dilated by 2.5 mm) versus CTV-based (minimax) robust optimization (2.5 mm setup, 3% range error) was assessed by comparing the prescription with the planned dose for a set of error scenarios. Results: In order to ensure dose coverage above 95% of the prescribed dose in more than 95% of the GTVPET voxels while compensating for the uncertainties, the plans with a PTV generated a high overdose. For the nominal case, up to 35% of the GTVPET received doses 5% beyond prescription. For the worst of the evaluated error scenarios, the volume with 5% overdose increased to 50%. In contrast, for CTV-based plans this 5% overdose was present only in a small fraction of the GTVPET, which ranged from 7% in the nominal case to 15% in the worst of the evaluated scenarios. Conclusion: The use of a PTV leads to non-robust dose distributions with excessive overdose in the painted volume. In contrast, robust optimization yields robust dose distributions with limited overdose. RaySearch Laboratories is sincerely acknowledged for providing us with RayStation treatment planning system and for the support provided.« less
Strudwick, Gillian; Reisdorfer, Emilene; Warnock, Caroline; Kalia, Kamini; Sulkers, Heather; Clark, Carrie; Booth, Richard
In an effort to prevent medication errors, barcode medication administration technology has been implemented in many health care organizations. An integrative review was conducted to understand the effect of barcode medication administration technology on medication errors, and characteristics of use demonstrated by nurses contribute to medication safety. Addressing poor system use may support improved patient safety through the reduction of medication administration errors.
Ben Natan, Merav; Sharon, Ira; Mahajna, Marlen; Mahajna, Sara
2017-11-01
Medication errors are common among nursing students. Nonetheless, these errors are often underreported. To examine factors related to nursing students' intention to report medication errors, using the Theory of Planned Behavior, and to examine whether the theory is useful in predicting students' intention to report errors. This study has a descriptive cross-sectional design. Study population was recruited in a university and a large nursing school in central and northern Israel. A convenience sample of 250 nursing students took part in the study. The students completed a self-report questionnaire, based on the Theory of Planned Behavior. The findings indicate that students' intention to report medication errors was high. The Theory of Planned Behavior constructs explained 38% of variance in students' intention to report medication errors. The constructs of behavioral beliefs, subjective norms, and perceived behavioral control were found as affecting this intention, while the most significant factor was behavioral beliefs. The findings also reveal that students' fear of the reaction to disclosure of the error from superiors and colleagues may impede them from reporting the error. Understanding factors related to reporting medication errors is crucial to designing interventions that foster error reporting. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ignaut, Debra A; Opincar, Michael R; Clark, Paula E; Palaisa, Melanie K; Lenox, Sheila M
2009-12-01
This study compared injection force (measured by glide force [GF] and glide force variability [GFV]) and dosing accuracy of the Humalog KwikPen * (prefilled insulin lispro [Humalog dagger] pen, Eli Lilly and Company, Indianapolis, IN) and the Next Generation FlexPen double dagger (prefilled insulin aspart [NovoRapid section sign] pen, Novo Nordisk A/S, Bagsvaerd, Denmark). * Humalog KwikPen is a registered trademark of Eli Lilly and Company, Indianapolis, IN, USA. dagger Humalog is a registered trademark of Eli Lilly and Company, Indianapolis, IN, USA. double dagger FlexPen is a registered trademark of Novo Nordisk A/S, Bagsvaerd, Denmark. section sign NovoRapid is a registered trademark of Novo Nordisk A/S, Bagsvaerd, Denmark. A total of 100 prefilled insulin pens (50 insulin lispro pens, 50 insulin aspart pens) were tested using two dose sizes (30 U and 60 U). In all, 50 devices (25 of each type) were tested at 10 U/s dosing speed and 50 were tested at 6.6 U/s. Devices were used per manufacturer instructions. Dose accuracy (represented as absolute dose error %), maximum and average GF, and GFV data were automatically collected by the test system for all datasets (dose size/dosing speed/device type). The test system controlled for potential dosing errors. The insulin lispro pen demonstrated a significantly lower median maximum GF at both dosing speeds: (2.83 vs. 3.92 lbs [30 U] and 3.00 vs. 4.14 lbs [60 U]) at 10 U/s; (1.85 vs. 2.93 lbs [30 U] and 2.14 vs. 3.02 lbs [60 U]) at 6.6 U/s, all p < 0.0001. For all datasets, the median GFV was significantly lower for the insulin lispro pen, p < 0.0001. Median dose error was comparable between device types when tested at 10 U/s dosing speed; however, at 6.6 U/s, the median dose error was significantly lower for insulin lispro pen compared to insulin aspart pen (0.47 vs. 0.67% [30 U] and 0.50 vs. 0.78% [60 U], both p < 0.05). The insulin lispro pen had significantly lower median GF and GFV compared with insulin aspart pen when tested at two dose sizes and two dosing speeds. Median dose error was similar between the device types at the 10 U/s dosing speed, but median dose error was significantly lower for the insulin lispro pen at the 6.6 U/s dosing speed. A limitation of this study was that it was executed as an open label study.
The effectiveness of risk management program on pediatric nurses' medication error.
Dehghan-Nayeri, Nahid; Bayat, Fariba; Salehi, Tahmineh; Faghihzadeh, Soghrat
2013-09-01
Medication therapy is one of the most complex and high-risk clinical processes that nurses deal with. Medication error is the most common type of error that brings about damage and death to patients, especially pediatric ones. However, these errors are preventable. Identifying and preventing undesirable events leading to medication errors are the main risk management activities. The aim of this study was to investigate the effectiveness of a risk management program on the pediatric nurses' medication error rate. This study is a quasi-experimental one with a comparison group. In this study, 200 nurses were recruited from two main pediatric hospitals in Tehran. In the experimental hospital, we applied the risk management program for a period of 6 months. Nurses of the control hospital did the hospital routine schedule. A pre- and post-test was performed to measure the frequency of the medication error events. SPSS software, t-test, and regression analysis were used for data analysis. After the intervention, the medication error rate of nurses at the experimental hospital was significantly lower (P < 0.001) and the error-reporting rate was higher (P < 0.007) compared to before the intervention and also in comparison to the nurses of the control hospital. Based on the results of this study and taking into account the high-risk nature of the medical environment, applying the quality-control programs such as risk management can effectively prevent the occurrence of the hospital undesirable events. Nursing mangers can reduce the medication error rate by applying risk management programs. However, this program cannot succeed without nurses' cooperation.
Abdelaziz, Hani; Al Anany, Rasha; Elmalik, Ashraf; Saad, Mohammad; Prabhu, Kirti; Al-Tamimi, Haleema; Salah, Salem Abu; Cameron, Peter
2016-08-01
Background The presence of a clinical pharmacist in a hospital's Emergency Department (ED) is important to decrease the potential for medication errors. To our knowledge, no previous studies have been conducted to evaluate the impact of implementing clinical pharmacy services in the ED in Qatar. Objective To characterize the contributions of clinical pharmacists in a short stay unit of ED in order to implement and scale-up the service to all ED areas in the future. Methods A retrospective study conducted for 7 months in the ED of Hamad General Hospital, Qatar. The intervention recommendations were made by clinical pharmacists to the physician in charge during medical rounds. Results A total of 824 documented pharmacist recommendations were analyzed. The interventions included the following: Providing information to the physician (24.4 %) and recommending medication discontinuation (22.0 %), dose adjustment (19.3 %), medication addition (16.0 %), changes in frequency of medications (7.6 %), medication resumption (5.7 %), and patient education (5.0 %). Conclusion Clinical pharmacists in the ED studied play an important role in patient care.
A retrospective review of medical errors adjudicated in court between 2002 and 2012 in Spain.
Giraldo, Priscila; Sato, Luke; Sala, María; Comas, Merce; Dywer, Kathy; Castells, Xavier
2016-02-01
This paper describes verdicts in court involving injury-producing medical errors in Spain. A descriptive analysis of 1041 closed court verdicts from Spain between January 2002 and December 2012. It was determined whether a medical error had occurred, and among those with medical error (n = 270), characteristics and results of litigation were analyzed. Data on litigation were obtained from the Thomson Reuters Aranzadi Westlaw databases. All verdicts involving health system were reviewed and classified according to the presence of medical error. Among those, contributory factors, medical specialty involved, health impact (death, disability and severity) and results of litigation (resolution, time to verdict and economic compensations) were described. Medical errors were involved in 25.9% of court verdicts. The cause of medical error was a diagnosis-related problem in 25.1% and surgical treatment in 22.2%, and Obstetrics-Gynecology was the most frequent involved specialty (21%). Most of them were of high severity (59.4%), one-third (32%) caused death. The average time interval between the occurrence of the error and the verdict was 7.8 years. The average indemnity payment was €239 505.24; the highest was psychiatry (€7 585 075.86) and the lowest was Emergency Medicine (€69 871.19). This study indicates that in Spain medical errors are common among verdicts involving the health system, most of them causing high-severity adverse outcomes. The interval between the medical error and the verdict is excessive, and there is a wide range of economic compensation. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.
Morrison, Maeve; Cope, Vicki; Murray, Melanie
2018-05-15
Medication errors remain a commonly reported clinical incident in health care as highlighted by the World Health Organization's focus to reduce medication-related harm. This retrospective quantitative analysis examined medication errors reported by staff using an electronic Clinical Incident Management System (CIMS) during a 3-year period from April 2014 to April 2017 at a metropolitan mental health ward in Western Australia. The aim of the project was to identify types of medication errors and the context in which they occur and to consider recourse so that medication errors can be reduced. Data were retrieved from the Clinical Incident Management System database and concerned medication incidents from categorized tiers within the system. Areas requiring improvement were identified, and the quality of the documented data captured in the database was reviewed for themes pertaining to medication errors. Content analysis provided insight into the following issues: (i) frequency of problem, (ii) when the problem was detected, and (iii) characteristics of the error (classification of drug/s, where the error occurred, what time the error occurred, what day of the week it occurred, and patient outcome). Data were compared to the state-wide results published in the Your Safety in Our Hands (2016) report. Results indicated several areas upon which quality improvement activities could be focused. These include the following: structural changes; changes to policy and practice; changes to individual responsibilities; improving workplace culture to counteract underreporting of medication errors; and improvement in safety and quality administration of medications within a mental health setting. © 2018 Australian College of Mental Health Nurses Inc.
Mackie, Jane E; Bruce, Catherine D
2016-05-01
Accurate calculation of medication dosages can be challenging for nursing students. Specific interventions related to types of errors made by nursing students may improve the learning of this important skill. The objective of this study was to determine areas of challenge for students in performing medication dosage calculations in order to design interventions to improve this skill. Strengths and weaknesses in the teaching and learning of medication dosage calculations were assessed. These data were used to create online interventions which were then measured for the impact on student ability to perform medication dosage calculations. The setting of the study is one university in Canada. The qualitative research participants were 8 nursing students from years 1-3 and 8 faculty members. Quantitative results are based on test data from the same second year clinical course during the academic years 2012 and 2013. Students and faculty participated in one-to-one interviews; responses were recorded and coded for themes. Tests were implemented and scored, then data were assessed to classify the types and number of errors. Students identified conceptual understanding deficits, anxiety, low self-efficacy, and numeracy skills as primary challenges in medication dosage calculations. Faculty identified long division as a particular content challenge, and a lack of online resources for students to practice calculations. Lessons and online resources designed as an intervention to target mathematical and concepts and skills led to improved results and increases in overall pass rates for second year students for medication dosage calculation tests. This study suggests that with concerted effort and a multi-modal approach to supporting nursing students, their abilities to calculate dosages can be improved. The positive results in this study also point to the promise of cross-discipline collaborations between nursing and education. Copyright © 2016 Elsevier Ltd. All rights reserved.
WE-D-BRA-04: Online 3D EPID-Based Dose Verification for Optimum Patient Safety
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spreeuw, H; Rozendaal, R; Olaciregui-Ruiz, I
2015-06-15
Purpose: To develop an online 3D dose verification tool based on EPID transit dosimetry to ensure optimum patient safety in radiotherapy treatments. Methods: A new software package was developed which processes EPID portal images online using a back-projection algorithm for the 3D dose reconstruction. The package processes portal images faster than the acquisition rate of the portal imager (∼ 2.5 fps). After a portal image is acquired, the software seeks for “hot spots” in the reconstructed 3D dose distribution. A hot spot is in this study defined as a 4 cm{sup 3} cube where the average cumulative reconstructed dose exceedsmore » the average total planned dose by at least 20% and 50 cGy. If a hot spot is detected, an alert is generated resulting in a linac halt. The software has been tested by irradiating an Alderson phantom after introducing various types of serious delivery errors. Results: In our first experiment the Alderson phantom was irradiated with two arcs from a 6 MV VMAT H&N treatment having a large leaf position error or a large monitor unit error. For both arcs and both errors the linac was halted before dose delivery was completed. When no error was introduced, the linac was not halted. The complete processing of a single portal frame, including hot spot detection, takes about 220 ms on a dual hexacore Intel Xeon 25 X5650 CPU at 2.66 GHz. Conclusion: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for various kinds of gross delivery errors. The detection of hot spots was proven to be effective for the timely detection of these errors. Current work is focused on hot spot detection criteria for various treatment sites and the introduction of a clinical pilot program with online verification of hypo-fractionated (lung) treatments.« less
The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors.
Rangel, Alejandra; Palte, Gesa; Dunscombe, Peter
2010-07-01
Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. 9 head and neck (H&N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets (+/- 1 mm in two banks, +/- 0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H&N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.
Strategic planning to reduce medical errors: Part I--diagnosis.
Waldman, J Deane; Smith, Howard L
2012-01-01
Despite extensive dialogue and a continuing stream of proposed medical practice revisions, medical errors and adverse impacts persist. Connectivity of vital elements is often underestimated or not fully understood. This paper analyzes medical errors from a systems dynamics viewpoint (Part I). Our analysis suggests in Part II that the most fruitful strategies for dissolving medical errors include facilitating physician learning, educating patients about appropriate expectations surrounding treatment regimens, and creating "systematic" patient protections rather than depending on (nonexistent) perfect providers.
Armstrong, Gail E; Dietrich, Mary; Norman, Linda; Barnsteiner, Jane; Mion, Lorraine
Approximately a quarter of medication errors in the hospital occur at the administration phase, which is solely under the purview of the bedside nurse. The purpose of this study was to assess bedside nurses' perceived skills and attitudes about updated safety concepts and examine their impact on medication administration errors and adherence to safe medication administration practices. Findings support the premise that medication administration errors result from an interplay among system-, unit-, and nurse-level factors.
Farag, Amany; Blegen, Mary; Gedney-Lose, Amalia; Lose, Daniel; Perkhounkova, Yelena
2017-05-01
Medication errors are one of the most frequently occurring errors in health care settings. The complexity of the ED work environment places patients at risk for medication errors. Most hospitals rely on nurses' voluntary medication error reporting, but these errors are under-reported. The purpose of this study was to examine the relationship among work environment (nurse manager leadership style and safety climate), social capital (warmth and belonging relationships and organizational trust), and nurses' willingness to report medication errors. A cross-sectional descriptive design using a questionnaire with a convenience sample of emergency nurses was used. Data were analyzed using descriptive, correlation, Mann-Whitney U, and Kruskal-Wallis statistics. A total of 71 emergency nurses were included in the study. Emergency nurses' willingness to report errors decreased as the nurses' years of experience increased (r = -0.25, P = .03). Their willingness to report errors increased when they received more feedback about errors (r = 0.25, P = .03) and when their managers used a transactional leadership style (r = 0.28, P = .01). ED nurse managers can modify their leadership style to encourage error reporting. Timely feedback after an error report is particularly important. Engaging experienced nurses to understand error root causes could increase voluntary error reporting. Published by Elsevier Inc.
Alexander, John H; Levy, Elliott; Lawrence, Jack; Hanna, Michael; Waclawski, Anthony P; Wang, Junyuan; Califf, Robert M; Wallentin, Lars; Granger, Christopher B
2013-09-01
In ARISTOTLE, apixaban resulted in a 21% reduction in stroke, a 31% reduction in major bleeding, and an 11% reduction in death. However, approval of apixaban was delayed to investigate a statement in the clinical study report that "7.3% of subjects in the apixaban group and 1.2% of subjects in the warfarin group received, at some point during the study, a container of the wrong type." Rates of study medication dispensing error were characterized through reviews of study medication container tear-off labels in 6,520 participants from randomly selected study sites. The potential effect of dispensing errors on study outcomes was statistically simulated in sensitivity analyses in the overall population. The rate of medication dispensing error resulting in treatment error was 0.04%. Rates of participants receiving at least 1 incorrect container were 1.04% (34/3,273) in the apixaban group and 0.77% (25/3,247) in the warfarin group. Most of the originally reported errors were data entry errors in which the correct medication container was dispensed but the wrong container number was entered into the case report form. Sensitivity simulations in the overall trial population showed no meaningful effect of medication dispensing error on the main efficacy and safety outcomes. Rates of medication dispensing error were low and balanced between treatment groups. The initially reported dispensing error rate was the result of data recording and data management errors and not true medication dispensing errors. These analyses confirm the previously reported results of ARISTOTLE. © 2013.
Matsubara, Kazuo; Toyama, Akira; Satoh, Hiroshi; Suzuki, Hiroshi; Awaya, Toshio; Tasaki, Yoshikazu; Yasuoka, Toshiaki; Horiuchi, Ryuya
2011-04-01
It is obvious that pharmacists play a critical role as risk managers in the healthcare system, especially in medication treatment. Hitherto, there is not a single multicenter-survey report describing the effectiveness of clinical pharmacists in preventing medical errors from occurring in the wards in Japan. Thus, we conducted a 1-month survey to elucidate the relationship between the number of errors and working hours of pharmacists in the ward, and verified whether the assignment of clinical pharmacists to the ward would prevent medical errors between October 1-31, 2009. Questionnaire items for the pharmacists at 42 national university hospitals and a medical institute included the total and the respective numbers of medication-related errors, beds and working hours of pharmacist in 2 internal medicine and 2 surgical departments in each hospital. Regardless of severity, errors were consecutively reported to the Medical Security and Safety Management Section in each hospital. The analysis of errors revealed that longer working hours of pharmacists in the ward resulted in less medication-related errors; this was especially significant in the internal medicine ward (where a variety of drugs were used) compared with the surgical ward. However, the nurse assignment mode (nurse/inpatients ratio: 1 : 7-10) did not influence the error frequency. The results of this survey strongly indicate that assignment of clinical pharmacists to the ward is critically essential in promoting medication safety and efficacy.
Learning mechanisms to limit medication administration errors.
Drach-Zahavy, Anat; Pud, Dorit
2010-04-01
This paper is a report of a study conducted to identify and test the effectiveness of learning mechanisms applied by the nursing staff of hospital wards as a means of limiting medication administration errors. Since the influential report ;To Err Is Human', research has emphasized the role of team learning in reducing medication administration errors. Nevertheless, little is known about the mechanisms underlying team learning. Thirty-two hospital wards were randomly recruited. Data were collected during 2006 in Israel by a multi-method (observations, interviews and administrative data), multi-source (head nurses, bedside nurses) approach. Medication administration error was defined as any deviation from procedures, policies and/or best practices for medication administration, and was identified using semi-structured observations of nurses administering medication. Organizational learning was measured using semi-structured interviews with head nurses, and the previous year's reported medication administration errors were assessed using administrative data. The interview data revealed four learning mechanism patterns employed in an attempt to learn from medication administration errors: integrated, non-integrated, supervisory and patchy learning. Regression analysis results demonstrated that whereas the integrated pattern of learning mechanisms was associated with decreased errors, the non-integrated pattern was associated with increased errors. Supervisory and patchy learning mechanisms were not associated with errors. Superior learning mechanisms are those that represent the whole cycle of team learning, are enacted by nurses who administer medications to patients, and emphasize a system approach to data analysis instead of analysis of individual cases.
Sayler, Elaine; Eldredge-Hindy, Harriet; Dinome, Jessie; Lockamy, Virginia; Harrison, Amy S
2015-01-01
The planning procedure for Valencia and Leipzig surface applicators (VLSAs) (Nucletron, Veenendaal, The Netherlands) differs substantially from CT-based planning; the unfamiliarity could lead to significant errors. This study applies failure modes and effects analysis (FMEA) to high-dose-rate (HDR) skin brachytherapy using VLSAs to ensure safety and quality. A multidisciplinary team created a protocol for HDR VLSA skin treatments and applied FMEA. Failure modes were identified and scored by severity, occurrence, and detectability. The clinical procedure was then revised to address high-scoring process nodes. Several key components were added to the protocol to minimize risk probability numbers. (1) Diagnosis, prescription, applicator selection, and setup are reviewed at weekly quality assurance rounds. Peer review reduces the likelihood of an inappropriate treatment regime. (2) A template for HDR skin treatments was established in the clinic's electronic medical record system to standardize treatment instructions. This reduces the chances of miscommunication between the physician and planner as well as increases the detectability of an error. (3) A screen check was implemented during the second check to increase detectability of an error. (4) To reduce error probability, the treatment plan worksheet was designed to display plan parameters in a format visually similar to the treatment console display, facilitating data entry and verification. (5) VLSAs are color coded and labeled to match the electronic medical record prescriptions, simplifying in-room selection and verification. Multidisciplinary planning and FMEA increased detectability and reduced error probability during VLSA HDR brachytherapy. This clinical model may be useful to institutions implementing similar procedures. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Antimicrobials and therapeutic decision making: an historical perspective.
Quintiliani, R; Nightingale, C H
1991-01-01
In an effort to remedy inappropriate and excessive use of antimicrobials and to control costs, most hospitals have developed some type of antimicrobial management program. At Hartford Hospital, our most effective approaches have been those that reduce the chances for physician error, decrease the burden on ancillary services, and encourage short hospital stays. These include automatic correction of dose and dosing intervals of antimicrobials and, if possible, their conversion by pharmacy to cost-effective alternative agents; daily review of patients who are taking the drugs by an antimicrobial team; and replacement of parenteral with oral agents as soon as possible. Physician acceptance of these approaches will require significant changes in traditional prescribing styles and willingness to allow pharmacists to implement the recommendations of therapeutic and medical staff committees.
Qureshi, N A; Neyaz, Y; Khoja, T; Magzoub, M A; Haycox, A; Walley, T
2011-02-01
Medication errors are globally huge in magnitude and associated with high morbidity and mortality together with high costs and legal problems. Medication errors are caused by multiple factors related to health providers, consumers and health system, but most prescribing errors are preventable. This paper is the third of 3 review articles that form the background for a series of 5 interconnected studies of prescribing patterns and medication errors in the public and private primary health care sectors of Saudi Arabia. A MEDLINE search was conducted to identify papers published in peer-reviewed journals over the previous 3 decades. The paper reviews the etiology, prevention strategies, reporting mechanisms and the myriad consequences of medication errors.
The impact of using an intravenous workflow management system (IVWMS) on cost and patient safety.
Lin, Alex C; Deng, Yihong; Thaibah, Hilal; Hingl, John; Penm, Jonathan; Ivey, Marianne F; Thomas, Mark
2018-07-01
The aim of this study was to determine the financial costs associated with wasted and missing doses before and after the implementation of an intravenous workflow management system (IVWMS) and to quantify the number and the rate of detected intravenous (IV) preparation errors. A retrospective analysis of the sample hospital information system database was conducted using three months of data before and after the implementation of an IVWMS System (DoseEdge ® ) which uses barcode scanning and photographic technologies to track and verify each step of the preparation process. The financial impact associated with wasted and missing >IV doses was determined by combining drug acquisition, labor, accessory, and disposal costs. The intercepted error reports and pharmacist detected error reports were drawn from the IVWMS to quantify the number of errors by defined error categories. The total number of IV doses prepared before and after the implementation of the IVWMS system were 110,963 and 101,765 doses, respectively. The adoption of the IVWMS significantly reduced the amount of wasted and missing IV doses by 14,176 and 2268 doses, respectively (p < 0.001). The overall cost savings of using the system was $144,019 over 3 months. The total number of errors detected was 1160 (1.14%) after using the IVWMS. The implementation of the IVWMS facilitated workflow changes that led to a positive impact on cost and patient safety. The implementation of the IVWMS increased patient safety by enforcing standard operating procedures and bar code verifications. Published by Elsevier B.V.
The Impact of a Patient Safety Program on Medical Error Reporting
2005-05-01
307 The Impact of a Patient Safety Program on Medical Error Reporting Donald R. Woolever Abstract Background: In response to the occurrence of...a sentinel event—a medical error with serious consequences—Eglin U.S. Air Force (USAF) Regional Hospital developed and implemented a patient safety...communication, teamwork, and reporting. Objective: To determine the impact of a patient safety program on patterns of medical error reporting. Methods: This
The Relationship Between Work Commitment, Dynamic, and Medication Error.
Rezaiamin, Abdoolkarim; Pazokian, Marzieh; Zagheri Tafreshi, Mansoureh; Nasiri, Malihe
2017-05-01
Incidence of medication errors in intensive care unit (ICU) can cause irreparable damage for ICU patients. Therefore, it seems necessary to find the causes of medication errors in this section. Work commitment and dynamic might affect the incidence of medication errors in ICU. To assess the mentioned hypothesis, we performed a descriptive-analytical study which was carried out on 117 nurses working in ICU of educational hospitals in Tehran. Minick et al., Salyer et al., and Wakefield et al. scales were used for data gathering on work commitment, dynamic, and medication errors, respectively. Findings of the current study revealed that high work commitment in ICU nurses caused low number of medication errors, including intravenous and nonintravenous. We controlled the effects of confounding variables in detection of this relationship. In contrast, no significant association was found between work dynamic and different types of medication errors. Although the study did not observe any relationship between the dynamics and rate of medication errors, the training of nurses or nursing students to create a dynamic environment in hospitals can increase their interest in the profession and increase job satisfaction in them. Also they must have enough ability in work dynamic so that they don't confused and distracted result in frequent changes of orders, care plans, and procedures.
Niemann, Dorothee; Bertsche, Astrid; Meyrath, David; Koepf, Ellen D; Traiser, Carolin; Seebald, Katja; Schmitt, Claus P; Hoffmann, Georg F; Haefeli, Walter E; Bertsche, Thilo
2015-01-01
To prevent medication errors in drug handling in a paediatric ward. One in five preventable adverse drug events in hospitalised children is caused by medication errors. Errors in drug prescription have been studied frequently, but data regarding drug handling, including drug preparation and administration, are scarce. A three-step intervention study including monitoring procedure was used to detect and prevent medication errors in drug handling. After approval by the ethics committee, pharmacists monitored drug handling by nurses on an 18-bed paediatric ward in a university hospital prior to and following each intervention step. They also conducted a questionnaire survey aimed at identifying knowledge deficits. Each intervention step targeted different causes of errors. The handout mainly addressed knowledge deficits, the training course addressed errors caused by rule violations and slips, and the reference book addressed knowledge-, memory- and rule-based errors. The number of patients who were subjected to at least one medication error in drug handling decreased from 38/43 (88%) to 25/51 (49%) following the third intervention, and the overall frequency of errors decreased from 527 errors in 581 processes (91%) to 116/441 (26%). The issue of the handout reduced medication errors caused by knowledge deficits regarding, for instance, the correct 'volume of solvent for IV drugs' from 49-25%. Paediatric drug handling is prone to errors. A three-step intervention effectively decreased the high frequency of medication errors by addressing the diversity of their causes. Worldwide, nurses are in charge of drug handling, which constitutes an error-prone but often-neglected step in drug therapy. Detection and prevention of errors in daily routine is necessary for a safe and effective drug therapy. Our three-step intervention reduced errors and is suitable to be tested in other wards and settings. © 2014 John Wiley & Sons Ltd.
Giraldo, Priscila; Sato, Luke; Martínez-Sánchez, Jose M; Comas, Mercè; Dwyer, Kathy; Sala, Maria; Castells, Xavier
2016-08-30
To evaluate and compare the characteristics of court verdicts on medical errors allegedly harming patients in Spain and Massachusetts from 2002 to 2012. We reviewed 1041 closed court verdicts obtained from data on litigation in the Thomson Reuters Aranzadi Westlaw databases in Spain (Europe), and 370 closed court verdicts obtained from the Controlled Risk and Risk Management Foundation of Harvard Medical Institutions (CRICO/RMF) in Massachusetts (USA). We included closed court verdicts on medical errors. The definition of medical errors was based on that of the Institute of Medicine (USA). We excluded any agreements between parties before a judgement. Medical errors were involved in 25.9% of court verdicts in Spain and in 74% of those in Massachusetts. The most frequent cause of medical errors was a diagnosis-related problem (25.1%; 95% CI 20.7% to 31.1% in Spain; 35%; 95% CI 29.4% to 40.7% in Massachusetts). The proportion of medical errors classified as high severity was 34% higher in Spain than in Massachusetts (p=0.001). The most frequent factors contributing to medical errors in Spain were surgical and medical treatment (p=0.001). In Spain, 98.5% of medical errors resulted in compensation awards compared with only 6.9% in Massachusetts. This study reveals wide differences in litigation rates and the award of indemnity payments in Spain and Massachusetts; however, common features of both locations are the high rates of diagnosis-related problems and the long time interval until resolution. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Kupas, Douglas F; Shayhorn, Meghan A; Green, Paul; Payton, Thomas F
2012-01-01
Medications are essential to emergency medical services (EMS) agencies when providing lifesaving care, but the EMS environment has challenges related to safe medication storage when compared with a hospital setting. We developed a structured process, based on common pharmacy practices, to review medications carried by EMS agencies to identify situations that may lead to medication error and to determine some best practices that may reduce potential errors and the risk of patient harm. To provide a descriptive account of EMS practices related to carrying and storing medications that have the potential for causing a medication administration error or patient harm. Using a structured process for inspection, an emergency medicine pharmacist and emergency physician(s) reviewed the medication carrying and storage practices of all nine advanced life support ambulance agencies within a five-county EMS region. Each medication carried and stored by the EMS agency was inspected for predetermined and spontaneously observed issues that could lead to medication error. These issues were documented and photographed. Two EMS medical directors reviewed each potential error for the risk of producing patient harm and assigned each to a category of high, moderate, or low risk. Because issues of temperature on EMS medications have been addressed elsewhere, this study concentrated on potential for EMS medication administration errors exclusive of storage temperatures. When reviewing medications carried by the nine EMS agencies, 38 medication safety issues were identified (range 1 to 8 per EMS agency). Of these, 16 were considered to be high risk, 14 moderate risk, and eight low risk for patient harm. Examples of potential issues included carrying expired medications, container-labeling issues, different medications stored in look-alike vials or prefilled syringes in the same compartment, and carrying crystalloid solutions next to solutions premixed with a medication. When reviewing medications stored at the EMS agency stations, eight safety issues were identified (range from 0 to 4 per station), including five moderate-risk and three low-risk issues. No agency had any high-risk medication issues related to storage of medication stock in the station. We observed potential medication safety issues related to how medications are carried and stored at all nine EMS agencies in a five-county region. Understanding these issues may assist EMS agencies in reducing the potential for a medication error and risk of patient harm. More research is needed to determine whether following these suggested best practices for carrying medications on EMS vehicles actually reduces errors in medication administration by EMS providers or decreases patient harm.
Mobarakabadi, Sedigheh Sedigh; Ebrahimipour, Hosein; Najar, Ali Vafaie; Janghorban, Roksana; Azarkish, Fatemeh
2017-03-01
Patient's safety is one of the main objective in healthcare services; however medical errors are a prevalent potential occurrence for the patients in treatment systems. Medical errors lead to an increase in mortality rate of the patients and challenges such as prolonging of the inpatient period in the hospitals and increased cost. Controlling the medical errors is very important, because these errors besides being costly, threaten the patient's safety. To evaluate the attitudes of nurses and midwives toward the causes and rates of medical errors reporting. It was a cross-sectional observational study. The study population was 140 midwives and nurses employed in Mashhad Public Hospitals. The data collection was done through Goldstone 2001 revised questionnaire. SPSS 11.5 software was used for data analysis. To analyze data, descriptive and inferential analytic statistics were used. Standard deviation and relative frequency distribution, descriptive statistics were used for calculation of the mean and the results were adjusted as tables and charts. Chi-square test was used for the inferential analysis of the data. Most of midwives and nurses (39.4%) were in age range of 25 to 34 years and the lowest percentage (2.2%) were in age range of 55-59 years. The highest average of medical errors was related to employees with three-four years of work experience, while the lowest average was related to those with one-two years of work experience. The highest average of medical errors was during the evening shift, while the lowest were during the night shift. Three main causes of medical errors were considered: illegibile physician prescription orders, similarity of names in different drugs and nurse fatigueness. The most important causes for medical errors from the viewpoints of nurses and midwives are illegible physician's order, drug name similarity with other drugs, nurse's fatigueness and damaged label or packaging of the drug, respectively. Head nurse feedback, peer feedback, fear of punishment or job loss were considered as reasons for under reporting of medical errors. This research demonstrates the need for greater attention to be paid to the causes of medical errors.
Vassileva, J; Simeonov, F; Avramova-Cholakova, S
2015-07-01
According to the Bulgarian regulation for radiation protection at medical exposure, the National Centre of Radiobiology and Radiation Protection (NCRRP) is responsible for performing national dose surveys in diagnostic and interventional radiology and nuclear medicine and for establishing of national diagnostic reference levels (DRLs). The next national dose survey is under preparation to be performed in the period of 2015-16, with the aim to cover conventional radiography, mammography, conventional fluoroscopy, interventional and fluoroscopy guided procedures and CT. It will be performed electronically using centralised on-line data collection platform established by the NCRRP. The aim is to increase the response rate and to improve the accuracy by reducing human errors. The concept of the on-line dose data collection platform is presented. Radiological facilities are provided with a tool to determine local typical patient doses, and the NCRRP to establish national DRLs. Future work will include automatic retrieval of dose data from hospital picture archival and communicating system. The on-line data collection platform is expected to facilitate the process of dose audit and optimisation of radiological procedures in Bulgarian hospitals. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
An Interlaboratory Comparison of Dosimetry for a Multi-institutional Radiobiological
Seed, TM; Xiao, S; Manley, N; Nikolich-Zugich, J; Pugh, J; van den Brink, M; Hirabayashi, Y; Yasutomo, K; Iwama, A; Koyasu, S; Shterev, I; Sempowski, G; Macchiarini, F; Nakachi, K; Kunugi, KC; Hammer, CG; DeWerd, LA
2016-01-01
Purpose An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Methods Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. Results The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤ 5%. Comparable rates of ‘dosimetric compliance’ were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between ‘measured’ and ‘target’ doses, with errors falling largely between 0–20%. Outliers were most notable for OSL-based tests, while multiple tests by ‘non-compliant’ laboratories using orthovoltage x-rays contributed heavily to the wide variation in dosing errors. Conclusions For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized. PMID:26857121
Seed, Thomas M; Xiao, Shiyun; Manley, Nancy; Nikolich-Zugich, Janko; Pugh, Jason; Van den Brink, Marcel; Hirabayashi, Yoko; Yasutomo, Koji; Iwama, Atsushi; Koyasu, Shigeo; Shterev, Ivo; Sempowski, Gregory; Macchiarini, Francesca; Nakachi, Kei; Kunugi, Keith C; Hammer, Clifford G; Dewerd, Lawrence A
2016-01-01
An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤5%. Comparable rates of 'dosimetric compliance' were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between 'measured' and 'target' doses, with errors falling largely between 0 and 20%. Outliers were most notable for OSL-based tests, while multiple tests by 'non-compliant' laboratories using orthovoltage X-rays contributed heavily to the wide variation in dosing errors. For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized.
2008-01-01
One way in which physicians can respond to a medical error is to apologize. Apologies—statements that acknowledge an error and its consequences, take responsibility, and communicate regret for having caused harm—can decrease blame, decrease anger, increase trust, and improve relationships. Importantly, apologies also have the potential to decrease the risk of a medical malpractice lawsuit and can help settle claims by patients. Patients indicate they want and expect explanations and apologies after medical errors and physicians indicate they want to apologize. However, in practice, physicians tend to provide minimal information to patients after medical errors and infrequently offer complete apologies. Although fears about potential litigation are the most commonly cited barrier to apologizing after medical error, the link between litigation risk and the practice of disclosure and apology is tenuous. Other barriers might include the culture of medicine and the inherent psychological difficulties in facing one’s mistakes and apologizing for them. Despite these barriers, incorporating apology into conversations between physicians and patients can address the needs of both parties and can play a role in the effective resolution of disputes related to medical error. PMID:18972177
Information-Gathering Patterns Associated with Higher Rates of Diagnostic Error
ERIC Educational Resources Information Center
Delzell, John E., Jr.; Chumley, Heidi; Webb, Russell; Chakrabarti, Swapan; Relan, Anju
2009-01-01
Diagnostic errors are an important source of medical errors. Problematic information-gathering is a common cause of diagnostic errors among physicians and medical students. The objectives of this study were to (1) determine if medical students' information-gathering patterns formed clusters of similar strategies, and if so (2) to calculate the…
Analyzing communication errors in an air medical transport service.
Dalto, Joseph D; Weir, Charlene; Thomas, Frank
2013-01-01
Poor communication can result in adverse events. Presently, no standards exist for classifying and analyzing air medical communication errors. This study sought to determine the frequency and types of communication errors reported within an air medical quality and safety assurance reporting system. Of 825 quality assurance reports submitted in 2009, 278 were randomly selected and analyzed for communication errors. Each communication error was classified and mapped to Clark's communication level hierarchy (ie, levels 1-4). Descriptive statistics were performed, and comparisons were evaluated using chi-square analysis. Sixty-four communication errors were identified in 58 reports (21% of 278). Of the 64 identified communication errors, only 18 (28%) were classified by the staff to be communication errors. Communication errors occurred most often at level 1 (n = 42/64, 66%) followed by level 4 (21/64, 33%). Level 2 and 3 communication failures were rare (, 1%). Communication errors were found in a fifth of quality and safety assurance reports. The reporting staff identified less than a third of these errors. Nearly all communication errors (99%) occurred at either the lowest level of communication (level 1, 66%) or the highest level (level 4, 33%). An air medical communication ontology is necessary to improve the recognition and analysis of communication errors. Copyright © 2013 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.
Emergency department discharge prescription errors in an academic medical center
Belanger, April; Devine, Lauren T.; Lane, Aaron; Condren, Michelle E.
2017-01-01
This study described discharge prescription medication errors written for emergency department patients. This study used content analysis in a cross-sectional design to systematically categorize prescription errors found in a report of 1000 discharge prescriptions submitted in the electronic medical record in February 2015. Two pharmacy team members reviewed the discharge prescription list for errors. Open-ended data were coded by an additional rater for agreement on coding categories. Coding was based upon majority rule. Descriptive statistics were used to address the study objective. Categories evaluated were patient age, provider type, drug class, and type and time of error. The discharge prescription error rate out of 1000 prescriptions was 13.4%, with “incomplete or inadequate prescription” being the most commonly detected error (58.2%). The adult and pediatric error rates were 11.7% and 22.7%, respectively. The antibiotics reviewed had the highest number of errors. The highest within-class error rates were with antianginal medications, antiparasitic medications, antacids, appetite stimulants, and probiotics. Emergency medicine residents wrote the highest percentage of prescriptions (46.7%) and had an error rate of 9.2%. Residents of other specialties wrote 340 prescriptions and had an error rate of 20.9%. Errors occurred most often between 10:00 am and 6:00 pm. PMID:28405061
Ziaeian, Boback; Araujo, Katy L B; Van Ness, Peter H; Horwitz, Leora I
2012-11-01
Adverse drug events after hospital discharge are common and often serious. These events may result from provider errors or patient misunderstanding. To determine the prevalence of medication reconciliation errors and patient misunderstanding of discharge medications. Prospective cohort study Patients over 64 years of age admitted with heart failure, acute coronary syndrome or pneumonia and discharged to home. We assessed medication reconciliation accuracy by comparing admission to discharge medication lists and reviewing charts to resolve discrepancies. Medication reconciliation changes that did not appear intentional were classified as suspected provider errors. We assessed patient understanding of intended medication changes through post-discharge interviews. Understanding was scored as full, partial or absent. We tested the association of relevance of the medication to the primary diagnosis with medication accuracy and with patient understanding, accounting for patient demographics, medical team and primary diagnosis. A total of 377 patients were enrolled in the study. A total of 565/2534 (22.3 %) of admission medications were redosed or stopped at discharge. Of these, 137 (24.2 %) were classified as suspected provider errors. Excluding suspected errors, patients had no understanding of 142/205 (69.3 %) of redosed medications, 182/223 (81.6 %) of stopped medications, and 493 (62.0 %) of new medications. Altogether, 307 patients (81.4 %) either experienced a provider error, or had no understanding of at least one intended medication change. Providers were significantly more likely to make an error on a medication unrelated to the primary diagnosis than on a medication related to the primary diagnosis (odds ratio (OR) 4.56, 95 % confidence interval (CI) 2.65, 7.85, p<0.001). Patients were also significantly more likely to misunderstand medication changes unrelated to the primary diagnosis (OR 2.45, 95 % CI 1.68, 3.55), p<0.001). Medication reconciliation and patient understanding are inadequate in older patients post-discharge. Errors and misunderstandings are particularly common in medications unrelated to the primary diagnosis. Efforts to improve medication reconciliation and patient understanding should not be disease-specific, but should be focused on the whole patient.
Fentanyl patches: preventable overdose.
2010-02-01
Fentanyl is a potent opioid analgesic marketed for the treatment of stable intense chronic pain, particularly in the form of a transdermal patch. These delivery devices carry the same risk of adverse effects and drug interactions as conventional formulations of opioids. The patches carry an added risk of fentanyl overdose because they contain very high doses, both before and after use. High-risk situations for overdose were identified by examining the results of pharmacovigilance studies and medication error prevention programmes, as well as an observational study, case reports, and a French legal action. The main situations exposing patients to a risk of overdose are: confusion between two dose strengths, forgetting to remove the patch; accidental transfer of the patch to another person, application of more than one patch, cutting the patches, self-medication, and ingestion. Increased skin temperature facilitates fentanyl absorption and thus increases the risk of overdose; high-risk situations include fever, electric blankets, and intense physical exercise. In practice, the precautions for treatment and patch disposal must be followed exactly if this delivery system is to serve as a valid alternative to morphine for selected patients with stable intense chronic pain.
The role of medical staff in providing patients rights.
Masic, Izet; Izetbegovic, Sebija
2014-01-01
Among the priority basic human rights, without a doubt, are the right to life and health-social protection. The process of implementation of human rights in the everyday life of an ordinary citizen in the post-war recovery of Bosnia and Herzegovina faces huge objective and subjective difficulties. Citizens need to be affordable adequate healthcare facilities that will be open to all on equal terms. The term hospital activity implies a set of measures, activities and procedures that are undertaken for the purpose of treatment, diagnosis and medical rehabilitation of patients in the respective health institutions. Principles of hospital care should include: Comprehensiveness (Hospital care is available to all citizens equally); Continuity (Provided is continuous medical care to all users); Availability (Provided approximately equal protection of rights for all citizens). Education of health professionals: The usual threats to patient safety include medical errors, infections occurred in the hospital, unnecessary exposure to high doses of radiation and the use of the wrong drug. Everyday continuing education in the profession of a doctor is lifelong.
Vigoda, Michael M; Gencorelli, Frank J; Lubarsky, David A
2007-10-01
Accurate recording of disposition of controlled substances is required by regulatory agencies. Linking anesthesia information management systems (AIMS) with medication dispensing systems may facilitate automated reconciliation of medication discrepancies. In this retrospective investigation at a large academic hospital, we reviewed 11,603 cases (spanning an 8-mo period) comparing records of medications (i.e., narcotics, benzodiazepines, ketamine, and thiopental) recorded as removed from our automated medication dispensing system with medications recorded as administered in our AIMS. In 15% of cases, we found discrepancies between dispensed versus administered medications. Discrepancies occurred in both the AIMS (8% cases) and the medication dispensing system (10% cases). Although there were many different types of user errors, nearly 75% of them resulted from either an error in the amount of drug waste documented in the medication dispensing system (35%); or an error in documenting the medication in the AIMS (40%). A significant percentage of cases contained data entry errors in both the automated dispensing and AIMS. This error rate limits the current practicality of automating the necessary reconciliation. An electronic interface between an AIMS and a medication dispensing system could alert users of medication entry errors prior to finalizing a case, thus reducing the time (and cost) of reconciling discrepancies.
Karlsson, Kristin; Lax, Ingmar; Lindbäck, Elias; Poludniowski, Gavin
2017-09-01
Geometrical uncertainties can result in a delivered dose to the tumor different from that estimated in the static treatment plan. The purpose of this project was to investigate the accuracy of the dose calculated to the clinical target volume (CTV) with the dose-shift approximation, in stereotactic body radiation therapy (SBRT) of lung tumors considering setup errors and breathing motion. The dose-shift method was compared with a beam-shift method with dose recalculation. Included were 10 patients (10 tumors) selected to represent a variety of SBRT-treated lung tumors in terms of tumor location, CTV volume, and tumor density. An in-house developed toolkit within a treatment planning system allowed the shift of either the dose matrix or a shift of the beam isocenter with dose recalculation, to simulate setup errors and breathing motion. Setup shifts of different magnitudes (up to 10 mm) and directions as well as breathing with different peak-to-peak amplitudes (up to 10:5:5 mm) were modeled. The resulting dose-volume histograms (DVHs) were recorded and dose statistics were extracted. Generally, both the dose-shift and beam-shift methods resulted in calculated doses lower than the static planned dose, although the minimum (D 98% ) dose exceeded the prescribed dose in all cases, for setup shifts up to 5 mm. The dose-shift method also generally underestimated the dose compared with the beam-shift method. For clinically realistic systematic displacements of less than 5 mm, the results demonstrated that in the minimum dose region within the CTV, the dose-shift method was accurate to 2% (root-mean-square error). Breathing motion only marginally degraded the dose distributions. Averaged over the patients and shift directions, the dose-shift approximation was determined to be accurate to approximately 2% (RMS) within the CTV, for clinically relevant geometrical uncertainties for SBRT of lung tumors.
Trattner, Sigal; Prinsen, Peter; Wiegert, Jens; Gerland, Elazar-Lars; Shefer, Efrat; Morton, Tom; Thompson, Carla M; Yagil, Yoad; Cheng, Bin; Jambawalikar, Sachin; Al-Senan, Rani; Amurao, Maxwell; Halliburton, Sandra S; Einstein, Andrew J
2017-12-01
Metal-oxide-semiconductor field-effect transistors (MOSFETs) serve as a helpful tool for organ radiation dosimetry and their use has grown in computed tomography (CT). While different approaches have been used for MOSFET calibration, those using the commonly available 100 mm pencil ionization chamber have not incorporated measurements performed throughout its length, and moreover, no previous work has rigorously evaluated the multiple sources of error involved in MOSFET calibration. In this paper, we propose a new MOSFET calibration approach to translate MOSFET voltage measurements into absorbed dose from CT, based on serial measurements performed throughout the length of a 100-mm ionization chamber, and perform an analysis of the errors of MOSFET voltage measurements and four sources of error in calibration. MOSFET calibration was performed at two sites, to determine single calibration factors for tube potentials of 80, 100, and 120 kVp, using a 100-mm-long pencil ion chamber and a cylindrical computed tomography dose index (CTDI) phantom of 32 cm diameter. The dose profile along the 100-mm ion chamber axis was sampled in 5 mm intervals by nine MOSFETs in the nine holes of the CTDI phantom. Variance of the absorbed dose was modeled as a sum of the MOSFET voltage measurement variance and the calibration factor variance, the latter being comprised of three main subcomponents: ionization chamber reading variance, MOSFET-to-MOSFET variation and a contribution related to the fact that the average calibration factor of a few MOSFETs was used as an estimate for the average value of all MOSFETs. MOSFET voltage measurement error was estimated based on sets of repeated measurements. The calibration factor overall voltage measurement error was calculated from the above analysis. Calibration factors determined were close to those reported in the literature and by the manufacturer (~3 mV/mGy), ranging from 2.87 to 3.13 mV/mGy. The error σ V of a MOSFET voltage measurement was shown to be proportional to the square root of the voltage V: σV=cV where c = 0.11 mV. A main contributor to the error in the calibration factor was the ionization chamber reading error with 5% error. The usage of a single calibration factor for all MOSFETs introduced an additional error of about 5-7%, depending on the number of MOSFETs that were used to determine the single calibration factor. The expected overall error in a high-dose region (~30 mGy) was estimated to be about 8%, compared to 6% when an individual MOSFET calibration was performed. For a low-dose region (~3 mGy), these values were 13% and 12%. A MOSFET calibration method was developed using a 100-mm pencil ion chamber and a CTDI phantom, accompanied by an absorbed dose error analysis reflecting multiple sources of measurement error. When using a single calibration factor, per tube potential, for different MOSFETs, only a small error was introduced into absorbed dose determinations, thus supporting the use of a single calibration factor for experiments involving many MOSFETs, such as those required to accurately estimate radiation effective dose. © 2017 American Association of Physicists in Medicine.
Stetson, Peter D.; McKnight, Lawrence K.; Bakken, Suzanne; Curran, Christine; Kubose, Tate T.; Cimino, James J.
2002-01-01
Medical errors are common, costly and often preventable. Work in understanding the proximal causes of medical errors demonstrates that systems failures predispose to adverse clinical events. Most of these systems failures are due to lack of appropriate information at the appropriate time during the course of clinical care. Problems with clinical communication are common proximal causes of medical errors. We have begun a project designed to measure the impact of wireless computing on medical errors. We report here on our efforts to develop an ontology representing the intersection of medical errors, information needs and the communication space. We will use this ontology to support the collection, storage and interpretation of project data. The ontology’s formal representation of the concepts in this novel domain will help guide the rational deployment of our informatics interventions. A real-life scenario is evaluated using the ontology in order to demonstrate its utility.
A preliminary taxonomy of medical errors in family practice
Dovey, S; Meyers, D; Phillips, R; Green, L; Fryer, G; Galliher, J; Kappus, J; Grob, P
2002-01-01
Objective: To develop a preliminary taxonomy of primary care medical errors. Design: Qualitative analysis to identify categories of error reported during a randomized controlled trial of computer and paper reporting methods. Setting: The National Network for Family Practice and Primary Care Research. Participants: Family physicians. Main outcome measures: Medical error category, context, and consequence. Results: Forty two physicians made 344 reports: 284 (82.6%) arose from healthcare systems dysfunction; 46 (13.4%) were errors due to gaps in knowledge or skills; and 14 (4.1%) were reports of adverse events, not errors. The main subcategories were: administrative failures (102; 30.9% of errors), investigation failures (82; 24.8%), treatment delivery lapses (76; 23.0%), miscommunication (19; 5.8%), payment systems problems (4; 1.2%), error in the execution of a clinical task (19; 5.8%), wrong treatment decision (14; 4.2%), and wrong diagnosis (13; 3.9%). Most reports were of errors that were recognized and occurred in reporters' practices. Affected patients ranged in age from 8 months to 100 years, were of both sexes, and represented all major US ethnic groups. Almost half the reports were of events which had adverse consequences. Ten errors resulted in patients being admitted to hospital and one patient died. Conclusions: This medical error taxonomy, developed from self-reports of errors observed by family physicians during their routine clinical practice, emphasizes problems in healthcare processes and acknowledges medical errors arising from shortfalls in clinical knowledge and skills. Patient safety strategies with most effect in primary care settings need to be broader than the current focus on medication errors. PMID:12486987
A preliminary taxonomy of medical errors in family practice.
Dovey, S M; Meyers, D S; Phillips, R L; Green, L A; Fryer, G E; Galliher, J M; Kappus, J; Grob, P
2002-09-01
To develop a preliminary taxonomy of primary care medical errors. Qualitative analysis to identify categories of error reported during a randomized controlled trial of computer and paper reporting methods. The National Network for Family Practice and Primary Care Research. Family physicians. Medical error category, context, and consequence. Forty two physicians made 344 reports: 284 (82.6%) arose from healthcare systems dysfunction; 46 (13.4%) were errors due to gaps in knowledge or skills; and 14 (4.1%) were reports of adverse events, not errors. The main subcategories were: administrative failure (102; 30.9% of errors), investigation failures (82; 24.8%), treatment delivery lapses (76; 23.0%), miscommunication (19; 5.8%), payment systems problems (4; 1.2%), error in the execution of a clinical task (19; 5.8%), wrong treatment decision (14; 4.2%), and wrong diagnosis (13; 3.9%). Most reports were of errors that were recognized and occurred in reporters' practices. Affected patients ranged in age from 8 months to 100 years, were of both sexes, and represented all major US ethnic groups. Almost half the reports were of events which had adverse consequences. Ten errors resulted in patients being admitted to hospital and one patient died. This medical error taxonomy, developed from self-reports of errors observed by family physicians during their routine clinical practice, emphasizes problems in healthcare processes and acknowledges medical errors arising from shortfalls in clinical knowledge and skills. Patient safety strategies with most effect in primary care settings need to be broader than the current focus on medication errors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, X; Li, Z; Zheng, D
Purpose: In the context of evaluating dosimetric impacts of a variety of uncertainties involved in HDR Tandem-and-Ovoid treatment, to study the correlations between conventional point doses and 3D volumetric doses. Methods: For 5 cervical cancer patients treated with HDR T&O, 150 plans were retrospectively created to study dosimetric impacts of the following uncertainties: (1) inter-fractional applicator displacement between two treatment fractions within a single insertion by applying Fraction#1 plan to Fraction#2 CT; (2) positional dwell error simulated from −5mm to 5mm in 1mm steps; (3) simulated temporal dwell error of 0.05s, 0.1s, 0.5s, and 1s. The original plans were basedmore » on point dose prescription, from which the volume covered by the prescription dose was generated as the pseudo target volume to study the 3D target dose effect. OARs were contoured. The point and volumetric dose errors were calculated by taking the differences between original and simulated plans. The correlations between the point and volumetric dose errors were analyzed. Results: For the most clinically relevant positional dwell uncertainty of 1mm, temporal uncertainty of 0.05s, and inter-fractional applicator displacement within the same insertion, the mean target D90 and V100 deviation were within 1%. Among these uncertainties, the applicator displacement showed the largest potential target coverage impact (2.6% on D90) as well as the OAR dose impact (2.5% and 3.4% on bladder D2cc and rectum D2cc). The Spearman correlation analysis shows a correlation coefficient of 0.43 with a p-value of 0.11 between target D90 coverage and H point dose. Conclusion: With the most clinically relevant positional and temporal dwell uncertainties and patient interfractional applicator displacement within the same insertion, the dose error is within clinical acceptable range. The lack of correlation between H point and 3D volumetric dose errors is a motivator for the use of 3D treatment planning in cervical HDR brachytherapy.« less
Kuikka, Liisa; Pitkälä, Kaisu
2014-01-01
Abstract Objective. To study coping differences between young and experienced GPs in primary care who experience medical errors and uncertainty. Design. Questionnaire-based survey (self-assessment) conducted in 2011. Setting. Finnish primary practice offices in Southern Finland. Subjects. Finnish GPs engaged in primary health care from two different respondent groups: young (working experience ≤ 5years, n = 85) and experienced (working experience > 5 years, n = 80). Main outcome measures. Outcome measures included experiences and attitudes expressed by the included participants towards medical errors and tolerance of uncertainty, their coping strategies, and factors that may influence (positively or negatively) sources of errors. Results. In total, 165/244 GPs responded (response rate: 68%). Young GPs expressed significantly more often fear of committing a medical error (70.2% vs. 48.1%, p = 0.004) and admitted more often than experienced GPs that they had committed a medical error during the past year (83.5% vs. 68.8%, p = 0.026). Young GPs were less prone to apologize to a patient for an error (44.7% vs. 65.0%, p = 0.009) and found, more often than their more experienced colleagues, on-site consultations and electronic databases useful for avoiding mistakes. Conclusion. Experienced GPs seem to better tolerate uncertainty and also seem to fear medical errors less than their young colleagues. Young and more experienced GPs use different coping strategies for dealing with medical errors. Implications. When GPs become more experienced, they seem to get better at coping with medical errors. Means to support these skills should be studied in future research. PMID:24914458
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, J; Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul; Park, H
Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from themore » whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (MSIP) (Grant No. 200900420)« less
The impact of work-related stress on medication errors in Eastern Region Saudi Arabia.
Salam, Abdul; Segal, David M; Abu-Helalah, Munir Ahmad; Gutierrez, Mary Lou; Joosub, Imran; Ahmed, Wasim; Bibi, Rubina; Clarke, Elizabeth; Qarni, Ali Ahmed Al
2018-05-07
To examine the relationship between overall level and source-specific work-related stressors on medication errors rate. A cross-sectional study examined the relationship between overall levels of stress, 25 source-specific work-related stressors and medication error rate based on documented incident reports in Saudi Arabia (SA) hospital, using secondary databases. King Abdulaziz Hospital in Al-Ahsa, Eastern Region, SA. Two hundred and sixty-nine healthcare professionals (HCPs). The odds ratio (OR) and corresponding 95% confidence interval (CI) for HCPs documented incident report medication errors and self-reported sources of Job Stress Survey. Multiple logistic regression analysis identified source-specific work-related stress as significantly associated with HCPs who made at least one medication error per month (P < 0.05), including disruption to home life, pressure to meet deadlines, difficulties with colleagues, excessive workload, income over 10 000 riyals and compulsory night/weekend call duties either some or all of the time. Although not statistically significant, HCPs who reported overall stress were two times more likely to make at least one medication error per month than non-stressed HCPs (OR: 1.95, P = 0.081). This is the first study to use documented incident reports for medication errors rather than self-report to evaluate the level of stress-related medication errors in SA HCPs. Job demands, such as social stressors (home life disruption, difficulties with colleagues), time pressures, structural determinants (compulsory night/weekend call duties) and higher income, were significantly associated with medication errors whereas overall stress revealed a 2-fold higher trend.
Programmable Infusion Pumps in ICUs: An Analysis of Corresponding Adverse Drug Events
Bower, Anthony G.; Paddock, Susan M.; Hilborne, Lee H.; Wallace, Peggy; Rothschild, Jeffrey M.; Griffin, Anne; Fairbanks, Rollin J.; Carlson, Beverly; Panzer, Robert J.; Brook, Robert H.
2007-01-01
Background Patients in intensive care units (ICUs) frequently experience adverse drug events involving intravenous medications (IV-ADEs), which are often preventable. Objectives To determine how frequently preventable IV-ADEs in ICUs match the safety features of a programmable infusion pump with safety software (“smart pump”) and to suggest potential improvements in smart-pump design. Design Using retrospective medical-record review, we examined preventable IV-ADEs in ICUs before and after 2 hospitals replaced conventional pumps with smart pumps. The smart pumps alerted users when programmed to deliver duplicate infusions or continuous-infusion doses outside hospital-defined ranges. Participants 4,604 critically ill adults at 1 academic and 1 nonacademic hospital. Measurements Preventable IV-ADEs matching smart-pump features and errors involved in preventable IV-ADEs. Results Of 100 preventable IV-ADEs identified, 4 involved errors matching smart-pump features. Two occurred before and 2 after smart-pump implementation. Overall, 29% of preventable IV-ADEs involved overdoses; 37%, failures to monitor for potential problems; and 45%, failures to intervene when problems appeared. Error descriptions suggested that expanding smart pumps’ capabilities might enable them to prevent more IV-ADEs. Conclusion The smart pumps we evaluated are unlikely to reduce preventable IV-ADEs in ICUs because they address only 4% of them. Expanding smart-pump capabilities might prevent more IV-ADEs. PMID:18095043
Variation in the days supply field for osteoporosis medications in Ontario.
Burden, Andrea M; Huang, Anjie; Tadrous, Mina; Cadarette, Suzanne M
2013-01-01
We examined pharmacy claims for osteoporosis medications dispensed in the community (78 %) and long-term care (LTC) to determine if days supply values matched expected dosing intervals. Results identify potential reporting errors that can have implications for drug exposure misclassification, particularly in LTC where only 59 % of reported values matched expected values. The days supply field is commonly used to examine patterns of drug utilization and classify drug exposure, yet its accuracy has received little attention. We sought to describe the days supply reported for osteoporosis drugs and examine if values matched expected therapeutic dosing intervals. We examined days supply values for osteoporosis medications submitted to the Ontario Drug Benefits program for seniors, 1997-2011. Days supply values were evaluated by dosing regimen and setting (community or long-term care [LTC]) and compared to pre-defined expected values. We defined expected days supply by the therapeutic dosing interval: daily in 7- or 30-day intervals, or as 100 days; weekly in 7- or 30-day intervals; monthly and daily nasal spray in 28- or 30-day intervals; and cyclical etidronate as a 90-day supply. We identified 17,615,404 osteoporosis prescriptions, with 78 % dispensed in the community. Most daily oral prescriptions were dispensed by an expected therapeutic dosing interval (97 %). Annual IV zoledronic acid was most commonly dispensed as a 1-day supply (62 %). Distinct differences in agreement were observed for other regimens, with the expected days supply more commonly reported in community versus LTC: cyclical etidronate (86 % vs. 40 %), weekly (91 % vs. 60 %), monthly (94 % vs. 35 %), and nasal spray (84 % vs. 40 %). Results suggest that inaccuracies in the days supply field exist, particularly among prescriptions dispensed in LTC. Inaccurate reporting may have significant implications for osteoporosis drug exposure misclassification.
SU-E-T-613: Dosimetric Consequences of Systematic MLC Leaf Positioning Errors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kathuria, K; Siebers, J
2014-06-01
Purpose: The purpose of this study is to determine the dosimetric consequences of systematic MLC leaf positioning errors for clinical IMRT patient plans so as to establish detection tolerances for quality assurance programs. Materials and Methods: Dosimetric consequences were simulated by extracting mlc delivery instructions from the TPS, altering the file by the specified error, reloading the delivery instructions into the TPS, recomputing dose, and extracting dose-volume metrics for one head-andneck and one prostate patient. Machine error was simulated by offsetting MLC leaves in Pinnacle in a systematic way. Three different algorithms were followed for these systematic offsets, and aremore » as follows: a systematic sequential one-leaf offset (one leaf offset in one segment per beam), a systematic uniform one-leaf offset (same one leaf offset per segment per beam) and a systematic offset of a given number of leaves picked uniformly at random from a given number of segments (5 out of 10 total). Dose to the PTV and normal tissue was simulated. Results: A systematic 5 mm offset of 1 leaf for all delivery segments of all beams resulted in a maximum PTV D98 deviation of 1%. Results showed very low dose error in all reasonably possible machine configurations, rare or otherwise, which could be simulated. Very low error in dose to PTV and OARs was shown in all possible cases of one leaf per beam per segment being offset (<1%), or that of only one leaf per beam being offset (<.2%). The errors resulting from a high number of adjacent leaves (maximum of 5 out of 60 total leaf-pairs) being simultaneously offset in many (5) of the control points (total 10–18 in all beams) per beam, in both the PTV and the OARs analyzed, were similarly low (<2–3%). Conclusions: The above results show that patient shifts and anatomical changes are the main source of errors in dose delivered, not machine delivery. These two sources of error are “visually complementary” and uncorrelated (albeit not additive in the final error) and one can easily incorporate error resulting from machine delivery in an error model based purely on tumor motion.« less
Using Six Sigma to reduce medication errors in a home-delivery pharmacy service.
Castle, Lon; Franzblau-Isaac, Ellen; Paulsen, Jim
2005-06-01
Medco Health Solutions, Inc. conducted a project to reduce medication errors in its home-delivery service, which is composed of eight prescription-processing pharmacies, three dispensing pharmacies, and six call-center pharmacies. Medco uses the Six Sigma methodology to reduce process variation, establish procedures to monitor the effectiveness of medication safety programs, and determine when these efforts do not achieve performance goals. A team reviewed the processes in home-delivery pharmacy and suggested strategies to improve the data-collection and medication-dispensing practices. A variety of improvement activities were implemented, including a procedure for developing, reviewing, and enhancing sound-alike/look-alike (SALA) alerts and system enhancements to improve processing consistency across the pharmacies. "External nonconformances" were reduced for several categories of medication errors, including wrong-drug selection (33%), wrong directions (49%), and SALA errors (69%). Control charts demonstrated evidence of sustained process improvement and actual reduction in specific medication error elements. Establishing a continuous quality improvement process to ensure that medication errors are minimized is critical to any health care organization providing medication services.
Dreisinger, Naomi; Zapolsky, Nathan
2017-02-01
The emergency department (ED) is an environment that is conducive to medical errors. The ED is a time-pressured environment where physicians aim to rapidly evaluate and treat patients. Quick thinking and problem-based solutions are often used to assist in evaluation and diagnosis. Error analysis leads to an understanding of the cause of a medical error and is important to prevent future errors. Research suggests mechanisms to prevent medical errors in the pediatric ED, but prevention is not always possible. Transparency about errors is necessary to assure a trusting doctor-patient relationship. Patients want to be informed about all errors, and apologies are hard. Apologizing for a significant medical error that may have caused a complication is even harder. Having a systematic way to go about apologizing makes the process easier, and helps assure that the right information is relayed to the patient and his or her family. This creates an environment of autonomy and shared decision making that is ultimately beneficial to all aspects of patient care.
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min -1 . Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean : R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
NASA Astrophysics Data System (ADS)
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min-1. Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean: R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
Medical errors; causes, consequences, emotional response and resulting behavioral change
Bari, Attia; Khan, Rehan Ahmed; Rathore, Ahsan Waheed
2016-01-01
Objective: To determine the causes of medical errors, the emotional and behavioral response of pediatric medicine residents to their medical errors and to determine their behavior change affecting their future training. Methods: One hundred thirty postgraduate residents were included in the study. Residents were asked to complete questionnaire about their errors and responses to their errors in three domains: emotional response, learning behavior and disclosure of the error. The names of the participants were kept confidential. Data was analyzed using SPSS version 20. Results: A total of 130 residents were included. Majority 128(98.5%) of these described some form of error. Serious errors that occurred were 24(19%), 63(48%) minor, 24(19%) near misses,2(2%) never encountered an error and 17(12%) did not mention type of error but mentioned causes and consequences. Only 73(57%) residents disclosed medical errors to their senior physician but disclosure to patient’s family was negligible 15(11%). Fatigue due to long duty hours 85(65%), inadequate experience 66(52%), inadequate supervision 58(48%) and complex case 58(45%) were common causes of medical errors. Negative emotions were common and were significantly associated with lack of knowledge (p=0.001), missing warning signs (p=<0.001), not seeking advice (p=0.003) and procedural complications (p=0.001). Medical errors had significant impact on resident’s behavior; 119(93%) residents became more careful, increased advice seeking from seniors 109(86%) and 109(86%) started paying more attention to details. Intrinsic causes of errors were significantly associated with increased information seeking behavior and vigilance (p=0.003) and (p=0.01) respectively. Conclusion: Medical errors committed by residents have inadequate disclosure to senior physicians and result in negative emotions but there was positive change in their behavior, which resulted in improvement in their future training and patient care. PMID:27375682
Byrne, Eamonn; Bury, Gerard
2018-02-08
Incident reporting is vital to identifying pre-hospital medication safety issues because literature suggests that the majority of errors pre-hospital are self-identified. In 2016, the National Ambulance Service (NAS) reported 11 medication errors to the national body with responsibility for risk management and insurance cover. The Health Information and Quality Authority in 2014 stated that reporting of clinical incidents, of which medication errors are a subset, was not felt to be representative of the actual events occurring. Even though reporting systems are in place, the levels appear to be well below what might be expected. Little data is available to explain this apparent discrepancy. To identify, investigate and document the barriers to medication error reporting within the NAS. An independent moderator led four focus groups in March of 2016. A convenience sample of 18 frontline Paramedics and Advanced Paramedics from Cork City and County discussed medication errors and the medication error reporting process. The sessions were recorded and anonymised, and the data was analysed using a process of thematic analysis. Practitioners understood the value of reporting errors. Barriers to reporting included fear of consequences and ridicule, procedural ambiguity, lack of feedback and a perceived lack of both consistency and confidentiality. The perceived consequences for making an error included professional, financial, litigious and psychological. Staff appeared willing to admit errors in a psychologically safe environment. Barriers to reporting are in line with international evidence. Time constraints prevented achievement of thematic saturation. Further study is warranted.
Amori, Renee E; Pittas, Anastassios G; Siegel, Richard D; Kumar, Sanjaya; Chen, Jack S; Karnam, Suneel; Golden, Sherita H; Salem, Deeb N
2008-01-01
To describe characteristics of inpatient medical errors involving hypoglycemic medications and their impact on patient care. We conducted a cross-sectional analysis of medical errors and associated adverse events voluntarily reported by hospital employees and staff in 21 nonprofit, nonfederal health-care organizations in the United States that implemented a Web-based electronic error-reporting system (e-ERS) between August 1, 2000, and December 31, 2005. Persons reporting the errors determined the level of impact on patient care. The median duration of e-ERS use was 3.1 years, and 2,598 inpatient error reports involved insulin or orally administered hypoglycemic agents. Nursing staff provided 59% of the reports; physicians reported <2%. Approximately two-thirds of the errors (1,693 of 2,598) reached the patient. Errors that caused temporary harm necessitating major treatment or that caused permanent harm accounted for 1.5% of reports (40 of 2,598). Insulin was involved in 82% of reports, and orally administered hypoglycemic agents were involved in 18% of all reports (473 of 2,598). Sulfonylureas were implicated in 51.8% of reports involving oral hypoglycemic agents (9.4% of all reports). An e-ERS provides an accessible venue for reporting and tracking inpatient medical errors involving glucose-lowering medications. Results are limited by potential underreporting of events, particularly by physicians, and variations in the reporter perception of patient harm.
Hospital medication errors in a pharmacovigilance system in Colombia.
Machado Alba, Jorge Enrique; Moreno Gutiérrez, Paula Andrea; Moncada Escobar, Juan Carlos
2015-11-01
this study analyzes the medication errors reported to a pharmacovigilance system by 26 hospitals for patients in the healthcare system of Colombia. this retrospective study analyzed the medication errors reported to a systematized database between 1 January 2008 and 12 September 2013. The medication is dispensed by the company Audifarma S.A. to hospitals and clinics around Colombia. Data were classified according to the taxonomy of the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP). The data analysis was performed using SPSS 22.0 for Windows, considering p-values < 0.05 significant. there were 9 062 medication errors in 45 hospital pharmacies. Real errors accounted for 51.9% (n = 4 707), of which 12.0% (n = 567) reached the patient (Categories C to I) and caused harm (Categories E to I) to 17 subjects (0.36%). The main process involved in errors that occurred (categories B to I) was prescription (n = 1 758, 37.3%), followed by dispensation (n = 1 737, 36.9%), transcription (n = 970, 20.6%) and administration (n = 242, 5.1%). The errors in the administration process were 45.2 times more likely to reach the patient (CI 95%: 20.2-100.9). medication error reporting systems and prevention strategies should be widespread in hospital settings, prioritizing efforts to address the administration process. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Gill, Christopher J; DeSilva, Mary Bachman; Hamer, Davidson H; Keyi, Xu; Wilson, Ira B; Sabin, Lora
2015-11-01
Adherence to antiretroviral medications is usually expressed in terms of the proportion of doses taken. However, the timing of doses taken may also be an important dimension to overall adherence. Little is known about whether patients who mistime doses are also more likely to skip doses. Using data from the completed Adherence for Life randomized controlled trial, we created visual and statistical models to capture and analyze dose timing data collected longitudinally with electronic drug monitors (EDM). From scatter plots depicting dose time versus calendar date, we identified dominant patterns of dose taking and calculated key features [slope of line over calendar date; residual mean standard error (RMSE)]. Each was assessed for its ability to categorize subjects with 'sub-optimal' (<95 % of doses taken) using area under the receiver operating characteristic (AROC) curve analysis. Sixty eight subjects contributed EDM data, with ~300 to 400 observations/subject. While regression line slopes did not predict 'sub-optimal' adherence (AROC 0.51, 95 % CI 0.26-0.75), the variability in dose timing (RMSE) was strongly predictive (AROC 0.79, 95 % CI 0.62-0.97). Compared with the lowest quartile of RMSE (minimal dose time variability), each successive quartile roughly doubled the odds of 'sub-optimal' adherence (OR 2.1, 95 % CI 1.3-3.4). Patterns of dose timing and mistiming are strongly related to overall adherence behavior. Notably, individuals who skip doses are more likely to mistime doses, with the degree of risk positively correlated with the extent of dose timing variability.
The intention to disclose medical errors among doctors in a referral hospital in North Malaysia.
Hs, Arvinder-Singh; Rashid, Abdul
2017-01-23
In this study, medical errors are defined as unintentional patient harm caused by a doctor's mistake. This topic, due to limited research, is poorly understood in Malaysia. The objective of this study was to determine the proportion of doctors intending to disclose medical errors, and their attitudes/perception pertaining to medical errors. This cross-sectional study was conducted at a tertiary public hospital from July- December 2015 among 276 randomly selected doctors. Data was collected using a standardized and validated self-administered questionnaire intending to measure disclosure and attitudes/perceptions. The scale had four vignettes in total two medical and two surgical. Each vignette consisted of five questions and each question measured the disclosure. Disclosure was categorised as "No Disclosure", "Partial Disclosure" or "Full Disclosure". Data was keyed in and analysed using STATA v 13.0. Only 10.1% (n = 28) intended to disclose medical errors. Most respondents felt that they possessed an attitude/perception of adequately disclosing errors to patients. There was a statistically significant difference (p < 0.001) when comparing the intention of disclosure with perceived disclosures. Most respondents were in common agreement that disclosing an error would make them less likely to get sued, that minor errors should be reported and that they experienced relief from disclosing errors. Most doctors in this study would not disclose medical errors although they perceived that the errors were serious and felt responsible for it. Poor disclosure could be due the fear of litigations and improper mechanisms/procedures available for disclosure.
Keers, Richard N; Williams, Steven D; Cooke, Jonathan; Ashcroft, Darren M
2015-01-01
Objectives To investigate the underlying causes of intravenous medication administration errors (MAEs) in National Health Service (NHS) hospitals. Setting Two NHS teaching hospitals in the North West of England. Participants Twenty nurses working in a range of inpatient clinical environments were identified and recruited using purposive sampling at each study site. Primary outcome measures Semistructured interviews were conducted with nurse participants using the critical incident technique, where they were asked to discuss perceived causes of intravenous MAEs that they had been directly involved with. Transcribed interviews were analysed using the Framework approach and emerging themes were categorised according to Reason's model of accident causation. Results In total, 21 intravenous MAEs were discussed containing 23 individual active failures which included slips and lapses (n=11), mistakes (n=8) and deliberate violations of policy (n=4). Each active failure was associated with a range of error and violation provoking conditions. The working environment was implicated when nurses lacked healthcare team support and/or were exposed to a perceived increased workload during ward rounds, shift changes or emergencies. Nurses frequently reported that the quality of intravenous dose-checking activities was compromised due to high perceived workload and working relationships. Nurses described using approaches such as subconscious functioning and prioritising to manage their duties, which at times contributed to errors. Conclusions Complex interactions between active and latent failures can lead to intravenous MAEs in hospitals. Future interventions may need to be multimodal in design in order to mitigate these risks and reduce the burden of intravenous MAEs. PMID:25770226
Tariq, Amina; Georgiou, Andrew; Westbrook, Johanna
2013-05-01
Medication safety is a pressing concern for residential aged care facilities (RACFs). Retrospective studies in RACF settings identify inadequate communication between RACFs, doctors, hospitals and community pharmacies as the major cause of medication errors. Existing literature offers limited insight about the gaps in the existing information exchange process that may lead to medication errors. The aim of this research was to explicate the cognitive distribution that underlies RACF medication ordering and delivery to identify gaps in medication-related information exchange which lead to medication errors in RACFs. The study was undertaken in three RACFs in Sydney, Australia. Data were generated through ethnographic field work over a period of five months (May-September 2011). Triangulated analysis of data primarily focused on examining the transformation and exchange of information between different media across the process. The findings of this study highlight the extensive scope and intense nature of information exchange in RACF medication ordering and delivery. Rather than attributing error to individual care providers, the explication of distributed cognition processes enabled the identification of gaps in three information exchange dimensions which potentially contribute to the occurrence of medication errors namely: (1) design of medication charts which complicates order processing and record keeping (2) lack of coordination mechanisms between participants which results in misalignment of local practices (3) reliance on restricted communication bandwidth channels mainly telephone and fax which complicates the information processing requirements. The study demonstrates how the identification of these gaps enhances understanding of medication errors in RACFs. Application of the theoretical lens of distributed cognition can assist in enhancing our understanding of medication errors in RACFs through identification of gaps in information exchange. Understanding the dynamics of the cognitive process can inform the design of interventions to manage errors and improve residents' safety. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Yan, M; Lovelock, D; Hunt, M; Mechalakos, J; Hu, Y; Pham, H; Jackson, A
2013-12-01
To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or -0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1-2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39-16.8) cGy, or 10.1 (0.8-32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%-9.06%) and 10.2% (0.7%-63.6%), respectively. Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup, the standard deviation of setup error reduced by 31%, 42%, and 54% in RL, AP, and SI direction, respectively, and consequently, the uncertainty of the mean dose to cochlea reduced more than 50%. The authors estimate that the effects of these uncertainties on the probability of hearing loss for an individual patient could be as large as 10%.
Yan, M.; Lovelock, D.; Hunt, M.; Mechalakos, J.; Hu, Y.; Pham, H.; Jackson, A.
2013-01-01
Purpose: To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Methods: Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. Results: The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or −0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1–2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39–16.8) cGy, or 10.1 (0.8–32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%–9.06%) and 10.2% (0.7%–63.6%), respectively. Conclusions: Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup, the standard deviation of setup error reduced by 31%, 42%, and 54% in RL, AP, and SI direction, respectively, and consequently, the uncertainty of the mean dose to cochlea reduced more than 50%. The authors estimate that the effects of these uncertainties on the probability of hearing loss for an individual patient could be as large as 10%. PMID:24320510
Shared Dosimetry Error in Epidemiological Dose-Response Analyses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stram, Daniel O.; Preston, Dale L.; Sokolnikov, Mikhail
2015-03-23
Radiation dose reconstruction systems for large-scale epidemiological studies are sophisticated both in providing estimates of dose and in representing dosimetry uncertainty. For example, a computer program was used by the Hanford Thyroid Disease Study to provide 100 realizations of possible dose to study participants. The variation in realizations reflected the range of possible dose for each cohort member consistent with the data on dose determinates in the cohort. Another example is the Mayak Worker Dosimetry System 2013 which estimates both external and internal exposures and provides multiple realizations of "possible" dose history to workers given dose determinants. This paper takesmore » up the problem of dealing with complex dosimetry systems that provide multiple realizations of dose in an epidemiologic analysis. In this paper we derive expected scores and the information matrix for a model used widely in radiation epidemiology, namely the linear excess relative risk (ERR) model that allows for a linear dose response (risk in relation to radiation) and distinguishes between modifiers of background rates and of the excess risk due to exposure. We show that treating the mean dose for each individual (calculated by averaging over the realizations) as if it was true dose (ignoring both shared and unshared dosimetry errors) gives asymptotically unbiased estimates (i.e. the score has expectation zero) and valid tests of the null hypothesis that the ERR slope β is zero. Although the score is unbiased the information matrix (and hence the standard errors of the estimate of β) is biased for β≠0 when ignoring errors in dose estimates, and we show how to adjust the information matrix to remove this bias, using the multiple realizations of dose. Use of these methods for several studies, including the Mayak Worker Cohort and the U.S. Atomic Veterans Study, is discussed.« less
Carrez, Laurent; Bouchoud, Lucie; Fleury-Souverain, Sandrine; Combescure, Christophe; Falaschi, Ludivine; Sadeghipour, Farshid; Bonnabry, Pascal
2017-03-01
Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, <5% deviation from the target concentration; weakly accurate, 5%-10%; inaccurate, 10%-30%; wrong, >30% deviation). Results Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods ( p = 0.63 Kruskal-Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Discussion Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.
Changes to Hospital Inpatient Volume After Newspaper Reporting of Medical Errors.
Fukuda, Haruhisa
2017-06-30
The aim of this study was to investigate the influence of medical error case reporting by national newspapers on inpatient volume at acute care hospitals. A case-control study was conducted using the article databases of 3 major Japanese newspapers with nationwide circulation between fiscal years 2012 and 2013. Data on inpatient volume at acute care hospitals were obtained from a Japanese government survey between fiscal years 2011 and 2014. Panel data were constructed and analyzed using a difference-in-differences design. Acute care hospitals in Japan. Hospitals named in articles that included the terms "medical error" and "hospital" were designated case hospitals, which were matched with control hospitals using corresponding locations, nurse-to-patient ratios, and bed numbers. Medical error case reporting in newspapers. Changes to hospital inpatient volume after error reports. The sample comprised 40 case hospitals and 40 control hospitals. Difference-in-differences analyses indicated that newspaper reporting of medical errors was not significantly associated (P = 0.122) with overall inpatient volume. Medical error case reporting by newspapers showed no influence on inpatient volume. Hospitals therefore have little incentive to respond adequately and proactively to medical errors. There may be a need for government intervention to improve the posterror response and encourage better health care safety.
Hakala, John L; Hung, Joseph C; Mosman, Elton A
2012-09-01
The objective of this project was to ensure correct radiopharmaceutical administration through the use of a bar code system that links patient and drug profiles with on-site information management systems. This new combined system would minimize the amount of manual human manipulation, which has proven to be a primary source of error. The most common reason for dosing errors is improper patient identification when a dose is obtained from the nuclear pharmacy or when a dose is administered. A standardized electronic transfer of information from radiopharmaceutical preparation to injection will further reduce the risk of misadministration. Value stream maps showing the flow of the patient dose information, as well as potential points of human error, were developed. Next, a future-state map was created that included proposed corrections for the most common critical sites of error. Transitioning the current process to the future state will require solutions that address these sites. To optimize the future-state process, a bar code system that links the on-site radiology management system with the nuclear pharmacy management system was proposed. A bar-coded wristband connects the patient directly to the electronic information systems. The bar code-enhanced process linking the patient dose with the electronic information reduces the number of crucial points for human error and provides a framework to ensure that the prepared dose reaches the correct patient. Although the proposed flowchart is designed for a site with an in-house central nuclear pharmacy, much of the framework could be applied by nuclear medicine facilities using unit doses. An electronic connection between information management systems to allow the tracking of a radiopharmaceutical from preparation to administration can be a useful tool in preventing the mistakes that are an unfortunate reality for any facility.
Zucker, Jason; Mittal, Jaimie; Jen, Shin-Pung; Cheng, Lucy; Cennimo, David
2016-03-01
There is a high prevalence of HIV infection in Newark, New Jersey, with University Hospital admitting approximately 600 HIV-infected patients per year. Medication errors involving antiretroviral therapy (ART) could significantly affect treatment outcomes. The goal of this study was to evaluate the effectiveness of various stewardship interventions in reducing the prevalence of prescribing errors involving ART. This was a retrospective review of all inpatients receiving ART for HIV treatment during three distinct 6-month intervals over a 3-year period. During the first year, the baseline prevalence of medication errors was determined. During the second year, physician and pharmacist education was provided, and a computerized order entry system with drug information resources and prescribing recommendations was implemented. Prospective audit of ART orders with feedback was conducted in the third year. Analyses and comparisons were made across the three phases of this study. Of the 334 patients with HIV admitted in the first year, 45% had at least one antiretroviral medication error and 38% had uncorrected errors at the time of discharge. After education and computerized order entry, significant reductions in medication error rates were observed compared to baseline rates; 36% of 315 admissions had at least one error and 31% had uncorrected errors at discharge. While the prevalence of antiretroviral errors in year 3 was similar to that of year 2 (37% of 276 admissions), there was a significant decrease in the prevalence of uncorrected errors at discharge (12%) with the use of prospective review and intervention. Interventions, such as education and guideline development, can aid in reducing ART medication errors, but a committed stewardship program is necessary to elicit the greatest impact. © 2016 Pharmacotherapy Publications, Inc.
The application of Aronson's taxonomy to medication errors in nursing.
Johnson, Maree; Young, Helen
2011-01-01
Medication administration is a frequent nursing activity that is prone to error. In this study of 318 self-reported medication incidents (including near misses), very few resulted in patient harm-7% required intervention or prolonged hospitalization or caused temporary harm. Aronson's classification system provided an excellent framework for analysis of the incidents with a close connection between the type of error and the change strategy to minimize medication incidents. Taking a behavioral approach to medication error classification has provided helpful strategies for nurses such as nurse-call cards on patient lockers when patients are absent and checking of medication sign-off by outgoing and incoming staff at handover.
Your Health Care May Kill You: Medical Errors.
Anderson, James G; Abrahamson, Kathleen
2017-01-01
Recent studies of medical errors have estimated errors may account for as many as 251,000 deaths annually in the United States (U.S)., making medical errors the third leading cause of death. Error rates are significantly higher in the U.S. than in other developed countries such as Canada, Australia, New Zealand, Germany and the United Kingdom (U.K). At the same time less than 10 percent of medical errors are reported. This study describes the results of an investigation of the effectiveness of the implementation of the MEDMARX Medication Error Reporting system in 25 hospitals in Pennsylvania. Data were collected on 17,000 errors reported by participating hospitals over a 12-month period. Latent growth curve analysis revealed that reporting of errors by health care providers increased significantly over the four quarters. At the same time, the proportion of corrective actions taken by the hospitals remained relatively constant over the 12 months. A simulation model was constructed to examine the effect of potential organizational changes resulting from error reporting. Four interventions were simulated. The results suggest that improving patient safety requires more than voluntary reporting. Organizational changes need to be implemented and institutionalized as well.
After the Medication Error: Recent Nursing Graduates' Reflections on Adequacy of Education.
Treiber, Linda A; Jones, Jackie H
2018-05-01
The purpose of this study was to better understand individual- and system-level factors surrounding making a medication error from the perspective of recent Bachelor of Science in Nursing graduates. Online survey mixed-methods items included perceptions of adequacy of preparatory nursing education, contributory variables, emotional responses, and treatment by employer following the error. Of the 168 respondents, 55% had made a medication error. Errors resulted from inexperience, rushing, technology, staffing, and patient acuity. Twenty-four percent did not report their errors. Key themes for improving education included more practice in varied clinical areas, intensive pharmacological preparation, practical instruction in functioning within the health care environment, and coping after making medication errors. Errors generally caused emotional distress in the error maker. Overall, perceived treatment after the error reflected supportive environments, where nurses were generally treated with respect, fair treatment, and understanding. Opportunities for nursing education include second victim awareness and reinforcing professional practice standards. [J Nurs Educ. 2018;57(5):275-280.]. Copyright 2018, SLACK Incorporated.
SU-E-T-425: Spherical Dose Distributions for Radiosurgery Using a Standardized MLC Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popple, R; Brezovich, I; Wu, X
2014-06-01
Purpose: To investigate a standardized MLC treatment plan to generate small spherical dose distributions. Methods: The static virtual cone plan comprised six table positions with clockwise and counterclockwise arcs having collimator angles 45 and 135 degrees, respectively, at each position. The central two leaves of a 2.5 mm leaf width MLC were set to a constant gap. Control points were weighted proportional to the sine of the gantry angle. Plans were created for the 10 MV flattening-filter-free beam of a TrueBeam STx (Varian Medical Systems) with gaps of 1, 1.5, 2, and 3 mm and were delivered to a phantommore » containing radiochromic film. Dose was calculated using the Eclipse AAA (Varian Medical Systems). A dynamic plan in which the table and gantry moved simultaneously with 1.5 mm gap was also created and delivered using the TrueBeam developer mode. Results: The full-width-half-max (FWHM) varied with leaf gap, ranging from 5.2 to 6.2 mm. Calculated FWHM was smaller than measured by 0.7 mm for the 1 mm gap and ≤ 0.4 mm for the larger gaps. The measured-to-calculated dose ratio was 0.93, 0.96, 1.01, and 0.99 for 1 mm, 1.5 mm, 2 mm, and 3 mm gaps, respectively. The dynamic results were the same as the static. The position deviations between the phantom target position and the center of the dose distribution were < 0.4 mm. Conclusion: The virtual cone can deliver spherical dose distributions suitable for radio surgery of small targets such as the trigeminal nerve. The Eclipse AAA accurately calculates the expected dose, particularly for leaf gap ≥ 1.5 mm. The measured dose distribution is slightly larger than the calculation, which is likely due to systematic leaf position error, isocenter variation due to gantry sag and table eccentricity, and inaccuracy in MLC leaf end modeling.« less
Kukush, Alexander; Shklyar, Sergiy; Masiuk, Sergii; Likhtarov, Illya; Kovgan, Lina; Carroll, Raymond J; Bouville, Andre
2011-02-16
With a binary response Y, the dose-response model under consideration is logistic in flavor with pr(Y=1 | D) = R (1+R)(-1), R = λ(0) + EAR D, where λ(0) is the baseline incidence rate and EAR is the excess absolute risk per gray. The calculated thyroid dose of a person i is expressed as Dimes=fiQi(mes)/Mi(mes). Here, Qi(mes) is the measured content of radioiodine in the thyroid gland of person i at time t(mes), Mi(mes) is the estimate of the thyroid mass, and f(i) is the normalizing multiplier. The Q(i) and M(i) are measured with multiplicative errors Vi(Q) and ViM, so that Qi(mes)=Qi(tr)Vi(Q) (this is classical measurement error model) and Mi(tr)=Mi(mes)Vi(M) (this is Berkson measurement error model). Here, Qi(tr) is the true content of radioactivity in the thyroid gland, and Mi(tr) is the true value of the thyroid mass. The error in f(i) is much smaller than the errors in ( Qi(mes), Mi(mes)) and ignored in the analysis. By means of Parametric Full Maximum Likelihood and Regression Calibration (under the assumption that the data set of true doses has lognormal distribution), Nonparametric Full Maximum Likelihood, Nonparametric Regression Calibration, and by properly tuned SIMEX method we study the influence of measurement errors in thyroid dose on the estimates of λ(0) and EAR. The simulation study is presented based on a real sample from the epidemiological studies. The doses were reconstructed in the framework of the Ukrainian-American project on the investigation of Post-Chernobyl thyroid cancers in Ukraine, and the underlying subpolulation was artificially enlarged in order to increase the statistical power. The true risk parameters were given by the values to earlier epidemiological studies, and then the binary response was simulated according to the dose-response model.
How Do Simulated Error Experiences Impact Attitudes Related to Error Prevention?
Breitkreuz, Karen R; Dougal, Renae L; Wright, Melanie C
2016-10-01
The objective of this project was to determine whether simulated exposure to error situations changes attitudes in a way that may have a positive impact on error prevention behaviors. Using a stratified quasi-randomized experiment design, we compared risk perception attitudes of a control group of nursing students who received standard error education (reviewed medication error content and watched movies about error experiences) to an experimental group of students who reviewed medication error content and participated in simulated error experiences. Dependent measures included perceived memorability of the educational experience, perceived frequency of errors, and perceived caution with respect to preventing errors. Experienced nursing students perceived the simulated error experiences to be more memorable than movies. Less experienced students perceived both simulated error experiences and movies to be highly memorable. After the intervention, compared with movie participants, simulation participants believed errors occurred more frequently. Both types of education increased the participants' intentions to be more cautious and reported caution remained higher than baseline for medication errors 6 months after the intervention. This study provides limited evidence of an advantage of simulation over watching movies describing actual errors with respect to manipulating attitudes related to error prevention. Both interventions resulted in long-term impacts on perceived caution in medication administration. Simulated error experiences made participants more aware of how easily errors can occur, and the movie education made participants more aware of the devastating consequences of errors.
Recognition of medical errors’ reporting system dimensions in educational hospitals
Yarmohammadian, Mohammad H.; Mohammadinia, Leila; Tavakoli, Nahid; Ghalriz, Parvin; Haghshenas, Abbas
2014-01-01
Introduction and Objective: Nowadays medical errors are one of the serious issues in the health-care system and carry to account of the patient's safety threat. The most important step for achieving safety promotion is identifying errors and their causes in order to recognize, correct and omit them. Concerning about repeating medical errors and harms, which were received via theses errors concluded to designing and establishing medical error reporting systems for hospitals and centers that are presenting therapeutic services. The aim of this study is the recognition of medical errors’ reporting system dimensions in educational hospitals. Materials and Methods: This research is a descriptive-analytical and qualities’ study, which has been carried out in Shahid Beheshti educational therapeutic center in Isfahan during 2012. In this study, relevant information was collected through 15 face to face interviews. That each of interviews take place in about 1hr and creation of five focused discussion groups through 45 min for each section, they were composed of Metron, educational supervisor, health officer, health education, and all of the head nurses. Concluded data interviews and discussion sessions were coded, then achieved results were extracted in the presence of clear-sighted persons and after their feedback perception, they were categorized. In order to make sure of information correctness, tables were presented to the research's interviewers and final the corrections were confirmed based on their view. Finding: The extracted information from interviews and discussion groups have been divided into nine main categories after content analyzing and subject coding and their subsets have been completely expressed. Achieved dimensions are composed of nine domains of medical error concept, error cases according to nurses’ prospection, medical error reporting barriers, employees’ motivational factors for error reporting, purposes of medical error reporting system, error reporting's challenges and opportunities, a desired system characteristics, and the quality of error experiences’ transmission in the health-care system. Conclusion: Although, appropriate achievements have been assured in Shahid Beheshti Hospital, but it seems necessary that in order to immune promotion not only in this hospital, but in the other organizations, necessary infrastructures have been provided for an error reporting system performance. An appropriate medical error reporting system could be educated and prevent the occurrence of repeated errors. PMID:25250342
Erlewein, Daniel; Bruni, Tommaso; Gadebusch Bondio, Mariacarla
2018-06-07
In 1983, McIntyre and Popper underscored the need for more openness in dealing with errors in medicine. Since then, much has been written on individual medical errors. Furthermore, at the beginning of the 21st century, researchers and medical practitioners increasingly approached individual medical errors through health information technology. Hence, the question arises whether the attention of biomedical researchers shifted from individual medical errors to health information technology. We ran a study to determine publication trends concerning individual medical errors and health information technology in medical journals over the last 40 years. We used the Medical Subject Headings (MeSH) taxonomy in the database MEDLINE. Each year, we analyzed the percentage of relevant publications to the total number of publications in MEDLINE. The trends identified were tested for statistical significance. Our analysis showed that the percentage of publications dealing with individual medical errors increased from 1976 until the beginning of the 21st century but began to drop in 2003. Both the upward and the downward trends were statistically significant (P < 0.001). A breakdown by country revealed that it was the weight of the US and British publications that determined the overall downward trend after 2003. On the other hand, the percentage of publications dealing with health information technology doubled between 2003 and 2015. The upward trend was statistically significant (P < 0.001). The identified trends suggest that the attention of biomedical researchers partially shifted from individual medical errors to health information technology in the USA and the UK. © 2018 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.
Quality assurance of dynamic parameters in volumetric modulated arc therapy.
Manikandan, A; Sarkar, B; Holla, R; Vivek, T R; Sujatha, N
2012-07-01
The purpose of this study was to demonstrate quality assurance checks for accuracy of gantry speed and position, dose rate and multileaf collimator (MLC) speed and position for a volumetric modulated arc treatment (VMAT) modality (Synergy S; Elekta, Stockholm, Sweden), and to check that all the necessary variables and parameters were synchronous. Three tests (for gantry position-dose delivery synchronisation, gantry speed-dose delivery synchronisation and MLC leaf speed and positions) were performed. The average error in gantry position was 0.5° and the average difference was 3 MU for a linear and a parabolic relationship between gantry position and delivered dose. In the third part of this test (sawtooth variation), the maximum difference was 9.3 MU, with a gantry position difference of 1.2°. In the sweeping field method test, a linear relationship was observed between recorded doses and distance from the central axis, as expected. In the open field method, errors were encountered at the beginning and at the end of the delivery arc, termed the "beginning" and "end" errors. For MLC position verification, the maximum error was -2.46 mm and the mean error was 0.0153 ±0.4668 mm, and 3.4% of leaves analysed showed errors of >±1 mm. This experiment demonstrates that the variables and parameters of the Synergy S are synchronous and that the system is suitable for delivering VMAT using a dynamic MLC.
Chedoe, Indra; Molendijk, Harry; Hospes, Wobbe; Van den Heuvel, Edwin R; Taxis, Katja
2012-11-01
To examine the effect of a multifaceted educational intervention on the incidence of medication preparation and administration errors in a neonatal intensive care unit (NICU). Prospective study with a preintervention and postintervention measurement using direct observation. NICU in a tertiary hospital in the Netherlands. A multifaceted educational intervention including teaching and self-study. The incidence of medication preparation and administration errors. Clinical importance was assessed by three experts. The incidence of errors decreased from 49% (43-54%) (151 medications with one or more errors of 311 observations) to 31% (87 of 284) (25-36%). Preintervention, 0.3% (0-2%) medications contained severe errors, 26% (21-31%) moderate and 23% (18-28%) minor errors; postintervention, none 0% (0-2%) was severe, 23% (18-28%) moderate and 8% (5-12%) minor. A generalised estimating equations analysis provided an OR of 0.49 (0.29-0.84) for period (p=0.032), (route of administration (p=0.001), observer within period (p=0.036)). The multifaceted educational intervention seemed to have contributed to a significant reduction of the preparation and administration error rate, but other measures are needed to improve medication safety further.
The Impact of Bar Code Medication Administration Technology on Reported Medication Errors
ERIC Educational Resources Information Center
Holecek, Andrea
2011-01-01
The use of bar-code medication administration technology is on the rise in acute care facilities in the United States. The technology is purported to decrease medication errors that occur at the point of administration. How significantly this technology affects actual rate and severity of error is unknown. This descriptive, longitudinal research…
Popoola, Victor O; Lau, Brandyn D; Tan, Esther; Shaffer, Dauryne L; Kraus, Peggy S; Farrow, Norma E; Hobson, Deborah B; Aboagye, Jonathan K; Streiff, Michael B; Haut, Elliott R
2018-03-15
Results of a study to characterize patterns of nonadministration of medication doses for venous thromboembolism (VTE) prevention among hospitalized patients are presented. The electronic records of all patients admitted to 4 floors of a medical center during a 1-month period were examined to identify patients whose records indicated at least 1 nonadministered dose of medication for VTE prophylaxis. Proportions of nonadministered doses by medication type, intended route of administration, and VTE risk categorization were compared; reasons for nonadministration were evaluated. Overall, 12.7% of all medication doses prescribed to patients in the study cohort ( n = 75) during the study period (857 of 6,758 doses in total) were not administered. Nonadministration of 1 or more doses of VTE prophylaxis medication was nearly twice as likely for subcutaneous anticoagulants than for all other medication types (231 of 1,112 doses [20.8%] versus 626 of 5,646 doses [11.2%], p < 0.001). For all medications prescribed, the most common reason for nonadministration was patient refusal (559 of 857 doses [65.2%]); the refusal rate was higher for subcutaneous anticoagulants than for all other medication categories (82.7% versus 58.8%, p < 0.001). Doses of antiretrovirals, immunosuppressives, antihypertensives, psychiatric medications, analgesics, and antiepileptics were less commonly missed than doses of electrolytes, vitamins, and gastrointestinal medications. Scheduled doses of subcutaneous anticoagulants for hospitalized patients were more likely to be missed than doses of all other medication types. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Patient safety awareness among Undergraduate Medical Students in Pakistani Medical School
Kamran, Rizwana; Bari, Attia; Khan, Rehan Ahmed; Al-Eraky, Mohamed
2018-01-01
Objective: To measure the level of awareness of patient safety among undergraduate medical students in Pakistani Medical School and to find the difference with respect to gender and prior experience with medical error. Methods: This cross-sectional study was conducted at the University of Lahore (UOL), Pakistan from January to March 2017, and comprised final year medical students. Data was collected using a questionnaire ‘APSQ- III’ on 7 point Likert scale. Eight questions were reverse coded. Survey was anonymous. SPSS package 20 was used for statistical analysis. Results: Questionnaire was filled by 122 students, with 81% response rate. The best score 6.17 was given for the ‘team functioning’, followed by 6.04 for ‘long working hours as a cause of medical error’. The domains regarding involvement of patient, confidence to report medical errors and role of training and learning on patient safety scored high in the agreed range of >5. Reverse coded questions about ‘professional incompetence as an error cause’ and ‘disclosure of errors’ showed negative perception. No significant differences of perceptions were found with respect to gender and prior experience with medical error (p= >0.05). Conclusion: Undergraduate medical students at UOL had a positive attitude towards patient safety. However, there were misconceptions about causes of medical errors and error disclosure among students and patient safety education needs to be incorporated in medical curriculum of Pakistan. PMID:29805398
Johnson, Terence L.; Zule, William A.; Carda-Auten, Jessica; Golin, Carol E.
2015-01-01
Ongoing injection drug use contributes to the HIV and HCV epidemics in people who inject drugs. In many places, pharmacies are the primary source of sterile syringes for people who inject drugs; thus, pharmacies provide a viable public health service that reduces blood-borne disease transmission. Replacing the supply of high dead space syringes with low dead space syringes could have far-reaching benefits that include further prevention of disease transmission in people who inject drugs and reductions in dosing inaccuracies, medication errors, and medication waste in patients who use syringes. We explored using pharmacies in a structural intervention to increase the uptake of low dead space syringes as part of a comprehensive strategy to reverse these epidemics. PMID:25880955
Oramasionwu, Christine U; Johnson, Terence L; Zule, William A; Carda-Auten, Jessica; Golin, Carol E
2015-06-01
Ongoing injection drug use contributes to the HIV and HCV epidemics in people who inject drugs. In many places, pharmacies are the primary source of sterile syringes for people who inject drugs; thus, pharmacies provide a viable public health service that reduces blood-borne disease transmission. Replacing the supply of high dead space syringes with low dead space syringes could have far-reaching benefits that include further prevention of disease transmission in people who inject drugs and reductions in dosing inaccuracies, medication errors, and medication waste in patients who use syringes. We explored using pharmacies in a structural intervention to increase the uptake of low dead space syringes as part of a comprehensive strategy to reverse these epidemics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamezawa, H; Fujimoto General Hospital, Miyakonojo, Miyazaki; Arimura, H
Purpose: To investigate the possibility of exposure dose reduction of the cone-beam computed tomography (CBCT) in an image guided patient positioning system by using 6 noise suppression filters. Methods: First, a reference dose (RD) and low-dose (LD)-CBCT (X-ray volume imaging system, Elekta Co.) images were acquired with a reference dose of 86.2 mGy (weighted CT dose index: CTDIw) and various low doses of 1.4 to 43.1 mGy, respectively. Second, an automated rigid registration for three axes was performed for estimating setup errors between a planning CT image and the LD-CBCT images, which were processed by 6 noise suppression filters, i.e.,more » averaging filter (AF), median filter (MF), Gaussian filter (GF), bilateral filter (BF), edge preserving smoothing filter (EPF) and adaptive partial median filter (AMF). Third, residual errors representing the patient positioning accuracy were calculated as an Euclidean distance between the setup error vectors estimated using the LD-CBCT image and RD-CBCT image. Finally, the relationships between the residual error and CTDIw were obtained for 6 noise suppression filters, and then the CTDIw for LD-CBCT images processed by the noise suppression filters were measured at the same residual error, which was obtained with the RD-CBCT. This approach was applied to an anthropomorphic pelvic phantom and two cancer patients. Results: For the phantom, the exposure dose could be reduced from 61% (GF) to 78% (AMF) by applying the noise suppression filters to the CBCT images. The exposure dose in a prostate cancer case could be reduced from 8% (AF) to 61% (AMF), and the exposure dose in a lung cancer case could be reduced from 9% (AF) to 37% (AMF). Conclusion: Using noise suppression filters, particularly an adaptive partial median filter, could be feasible to decrease the additional exposure dose to patients in image guided patient positioning systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Egan, A; Laub, W
2014-06-15
Purpose: Several shortcomings of the current implementation of the analytic anisotropic algorithm (AAA) may lead to dose calculation errors in highly modulated treatments delivered to highly heterogeneous geometries. Here we introduce a set of dosimetric error predictors that can be applied to a clinical treatment plan and patient geometry in order to identify high risk plans. Once a problematic plan is identified, the treatment can be recalculated with more accurate algorithm in order to better assess its viability. Methods: Here we focus on three distinct sources dosimetric error in the AAA algorithm. First, due to a combination of discrepancies inmore » smallfield beam modeling as well as volume averaging effects, dose calculated through small MLC apertures can be underestimated, while that behind small MLC blocks can overestimated. Second, due the rectilinear scaling of the Monte Carlo generated pencil beam kernel, energy is not properly transported through heterogeneities near, but not impeding, the central axis of the beamlet. And third, AAA overestimates dose in regions very low density (< 0.2 g/cm{sup 3}). We have developed an algorithm to detect the location and magnitude of each scenario within the patient geometry, namely the field-size index (FSI), the heterogeneous scatter index (HSI), and the lowdensity index (LDI) respectively. Results: Error indices successfully identify deviations between AAA and Monte Carlo dose distributions in simple phantom geometries. Algorithms are currently implemented in the MATLAB computing environment and are able to run on a typical RapidArc head and neck geometry in less than an hour. Conclusion: Because these error indices successfully identify each type of error in contrived cases, with sufficient benchmarking, this method can be developed into a clinical tool that may be able to help estimate AAA dose calculation errors and when it might be advisable to use Monte Carlo calculations.« less
Claims, errors, and compensation payments in medical malpractice litigation.
Studdert, David M; Mello, Michelle M; Gawande, Atul A; Gandhi, Tejal K; Kachalia, Allen; Yoon, Catherine; Puopolo, Ann Louise; Brennan, Troyen A
2006-05-11
In the current debate over tort reform, critics of the medical malpractice system charge that frivolous litigation--claims that lack evidence of injury, substandard care, or both--is common and costly. Trained physicians reviewed a random sample of 1452 closed malpractice claims from five liability insurers to determine whether a medical injury had occurred and, if so, whether it was due to medical error. We analyzed the prevalence, characteristics, litigation outcomes, and costs of claims that lacked evidence of error. For 3 percent of the claims, there were no verifiable medical injuries, and 37 percent did not involve errors. Most of the claims that were not associated with errors (370 of 515 [72 percent]) or injuries (31 of 37 [84 percent]) did not result in compensation; most that involved injuries due to error did (653 of 889 [73 percent]). Payment of claims not involving errors occurred less frequently than did the converse form of inaccuracy--nonpayment of claims associated with errors. When claims not involving errors were compensated, payments were significantly lower on average than were payments for claims involving errors (313,205 dollars vs. 521,560 dollars, P=0.004). Overall, claims not involving errors accounted for 13 to 16 percent of the system's total monetary costs. For every dollar spent on compensation, 54 cents went to administrative expenses (including those involving lawyers, experts, and courts). Claims involving errors accounted for 78 percent of total administrative costs. Claims that lack evidence of error are not uncommon, but most are denied compensation. The vast majority of expenditures go toward litigation over errors and payment of them. The overhead costs of malpractice litigation are exorbitant. Copyright 2006 Massachusetts Medical Society.
Baldwin, DeWitt C; Daugherty, Steven R; Ryan, Patrick M; Yaghmour, Nicholas A; Philibert, Ingrid
2018-04-01
Medical errors and patient safety are major concerns for the medical and medical education communities. Improving clinical supervision for residents is important in avoiding errors, yet little is known about how residents perceive the adequacy of their supervision and how this relates to medical errors and other education outcomes, such as learning and satisfaction. We analyzed data from a 2009 survey of residents in 4 large specialties regarding the adequacy and quality of supervision they receive as well as associations with self-reported data on medical errors and residents' perceptions of their learning environment. Residents' reports of working without adequate supervision were lower than data from a 1999 survey for all 4 specialties, and residents were least likely to rate "lack of supervision" as a problem. While few residents reported that they received inadequate supervision, problems with supervision were negatively correlated with sufficient time for clinical activities, overall ratings of the residency experience, and attending physicians as a source of learning. Problems with supervision were positively correlated with resident reports that they had made a significant medical error, had been belittled or humiliated, or had observed others falsifying medical records. Although working without supervision was not a pervasive problem in 2009, when it happened, it appeared to have negative consequences. The association between inadequate supervision and medical errors is of particular concern.
Medication errors in outpatient care in Colombia, 2005-2013.
Machado-Alba, Jorge E; Moncada, Juan Carlos; Moreno-Gutiérrez, Paula Andrea
2016-06-03
Medication errors outside the hospital have been poorly studied despite representing an important threat to patient safety. To describe the characteristics of medication errors in outpatient dispensing pharmacists reported in a pharmaco-surveillance system between 2005 and 2013 in Colombia. We conducted a descriptive study by reviewing and categorizing medication error reports from outpatient pharmacy services to a national medication dispensing company between January, 2005 and September, 2013. Variables considered included: process involved (administration, dispensing, prescription and transcription), wrong drug, time delay for the report, error type, cause and severity. The analysis was conducted in the SPSS® software, version 22.0. A total of 14,873 medication errors were reviewed, of which 67.2% in fact occurred, 15.5% reached the patient and 0.7% caused harm. Administration (OR=93.61, CI 95%: 48.510-180.655, p<0.001), dispensing (OR=21.58, CI 95%: 16.139-28.870, p<0.001), transcription errors (OR=5.64; CI 95%: 3.488-9.142, p<0.001), medicines for sensory organs (OR=2.04, CI 95%: 1.519-2.756, p<0.001), anti-infective drugs for systemic use (OR=1.99, CI 95%: 1.574-2.525, p0.001), confusion generated with the name of the drug (OR=1.28, CI 95%: 1.051-1.560, p=0.014), and trouble interpreting prescriptions (OR=1.32, CI 95%: 1.037-1.702, p=0.025) increased the risk for error reaching the patient. It is necessary to develop surveillance systems for medication errors in ambulatory care, focusing on the prescription, transcription and dispensation processes. Special strategies are needed for the prevention of medication errors related to anti-infective drugs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, M; Chetty, I; Zhong, H
2014-06-01
Purpose: Tumor control probability (TCP) calculated with accumulated radiation doses may help design appropriate treatment margins. Image registration errors, however, may compromise the calculated TCP. The purpose of this study is to develop benchmark CT images to quantify registration-induced errors in the accumulated doses and their corresponding TCP. Methods: 4DCT images were registered from end-inhale (EI) to end-exhale (EE) using a “demons” algorithm. The demons DVFs were corrected by an FEM model to get realistic deformation fields. The FEM DVFs were used to warp the EI images to create the FEM-simulated images. The two images combined with the FEM DVFmore » formed a benchmark model. Maximum intensity projection (MIP) images, created from the EI and simulated images, were used to develop IMRT plans. Two plans with 3 and 5 mm margins were developed for each patient. With these plans, radiation doses were recalculated on the simulated images and warped back to the EI images using the FEM DVFs to get the accumulated doses. The Elastix software was used to register the FEM-simulated images to the EI images. TCPs calculated with the Elastix-accumulated doses were compared with those generated by the FEM to get the TCP error of the Elastix registrations. Results: For six lung patients, the mean Elastix registration error ranged from 0.93 to 1.98 mm. Their relative dose errors in PTV were between 0.28% and 6.8% for 3mm margin plans, and between 0.29% and 6.3% for 5mm-margin plans. As the PTV margin reduced from 5 to 3 mm, the mean TCP error of the Elastix-reconstructed doses increased from 2.0% to 2.9%, and the mean NTCP errors decreased from 1.2% to 1.1%. Conclusion: Patient-specific benchmark images can be used to evaluate the impact of registration errors on the computed TCPs, and may help select appropriate PTV margins for lung SBRT patients.« less
A Cycle of Redemption in a Medical Error Disclosure and Apology Program.
Carmack, Heather J
2014-06-01
Physicians accept that they have an ethical responsibility to disclose and apologize for medical errors; however, when physicians make a medical error, they are often not given the opportunity to disclose and apologize for the mistake. In this article, I explore how one hospital negotiated the aftermath of medical mistakes through a disclosure and apology program. Specifically, I used Burke's cycle of redemption to position the hospital's disclosure and apology program as a redemption process and explore how the hospital physicians and administrators worked through the experiences of disclosing and apologizing for medical errors. © The Author(s) 2014.
A root cause analysis project in a medication safety course.
Schafer, Jason J
2012-08-10
To develop, implement, and evaluate team-based root cause analysis projects as part of a required medication safety course for second-year pharmacy students. Lectures, in-class activities, and out-of-class reading assignments were used to develop students' medication safety skills and introduce them to the culture of medication safety. Students applied these skills within teams by evaluating cases of medication errors using root cause analyses. Teams also developed error prevention strategies and formally presented their findings. Student performance was assessed using a medication errors evaluation rubric. Of the 211 students who completed the course, the majority performed well on root cause analysis assignments and rated them favorably on course evaluations. Medication error evaluation and prevention was successfully introduced in a medication safety course using team-based root cause analysis projects.
Using EHR Data to Detect Prescribing Errors in Rapidly Discontinued Medication Orders.
Burlison, Jonathan D; McDaniel, Robert B; Baker, Donald K; Hasan, Murad; Robertson, Jennifer J; Howard, Scott C; Hoffman, James M
2018-01-01
Previous research developed a new method for locating prescribing errors in rapidly discontinued electronic medication orders. Although effective, the prospective design of that research hinders its feasibility for regular use. Our objectives were to assess a method to retrospectively detect prescribing errors, to characterize the identified errors, and to identify potential improvement opportunities. Electronically submitted medication orders from 28 randomly selected days that were discontinued within 120 minutes of submission were reviewed and categorized as most likely errors, nonerrors, or not enough information to determine status. Identified errors were evaluated by amount of time elapsed from original submission to discontinuation, error type, staff position, and potential clinical significance. Pearson's chi-square test was used to compare rates of errors across prescriber types. In all, 147 errors were identified in 305 medication orders. The method was most effective for orders that were discontinued within 90 minutes. Duplicate orders were most common; physicians in training had the highest error rate ( p < 0.001), and 24 errors were potentially clinically significant. None of the errors were voluntarily reported. It is possible to identify prescribing errors in rapidly discontinued medication orders by using retrospective methods that do not require interrupting prescribers to discuss order details. Future research could validate our methods in different clinical settings. Regular use of this measure could help determine the causes of prescribing errors, track performance, and identify and evaluate interventions to improve prescribing systems and processes. Schattauer GmbH Stuttgart.
How Trainees Would Disclose Medical Errors: Educational Implications for Training Programs
White, Andrew A.; Bell, Sigall K.; Krauss, Melissa J; Garbutt, Jane; Dunagan, W. Claiborne; Fraser, Victoria J.; Levinson, Wendy; Larson, Eric B.; Gallagher, Thomas H.
2012-01-01
Background Disclosing harmful errors to patients is recommended, but appears to be uncommon. Understanding how trainees disclose errors and how those practices evolve during training could help educators design programs to address this gap. Purpose To determine how trainees would disclose medical errors. Methods A survey of 758 trainees (488 students and 270 residents) in internal medicine at two academic medical centers. Surveys depicted one of two harmful error scenarios that varied by how apparent the error would be to the patient. We measured attitudes and disclosure content using scripted responses. Results Trainees reported their intent to disclose the error as “definitely” (43%) “probably” (47%) “only if asked by patient” (9%), and “definitely not” (1%). Trainees were more likely to disclose obvious errors in comparison with ones patients were unlikely to recognize (55% vs. 30%, P<0.01). Respondents varied widely in what information they would disclose. Fifty percent of trainees chose statements explicitly stating an error occurred rather than only an adverse event. Regarding apologies, trainees were split between a general expression of regret (52%) and an explicit apology (46%). Respondents at higher levels of training were less likely to use explicit apologies (Trend P<0.01). Prior disclosure training was associated with increased willingness to disclose errors (OR 1.40, P=0.03). Conclusions Trainees may not be prepared to disclose medical errors to patients, and worrisome trends in trainee apology practices were observed across levels of training. Medical educators should intensify efforts to enhance trainees’ skills at meeting patients’ expectations for open disclosure of harmful medical errors. PMID:21401685
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prabhakar, Ramachandran; Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi; Department of Radiology, All India Institute of Medical Sciences, New Delhi
Setup error plays a significant role in the final treatment outcome in radiotherapy. The effect of setup error on the planning target volume (PTV) and surrounding critical structures has been studied and the maximum allowed tolerance in setup error with minimal complications to the surrounding critical structure and acceptable tumor control probability is determined. Twelve patients were selected for this study after breast conservation surgery, wherein 8 patients were right-sided and 4 were left-sided breast. Tangential fields were placed on the 3-dimensional-computed tomography (3D-CT) dataset by isocentric technique and the dose to the PTV, ipsilateral lung (IL), contralateral lung (CLL),more » contralateral breast (CLB), heart, and liver were then computed from dose-volume histograms (DVHs). The planning isocenter was shifted for 3 and 10 mm in all 3 directions (X, Y, Z) to simulate the setup error encountered during treatment. Dosimetric studies were performed for each patient for PTV according to ICRU 50 guidelines: mean doses to PTV, IL, CLL, heart, CLB, liver, and percentage of lung volume that received a dose of 20 Gy or more (V20); percentage of heart volume that received a dose of 30 Gy or more (V30); and volume of liver that received a dose of 50 Gy or more (V50) were calculated for all of the above-mentioned isocenter shifts and compared to the results with zero isocenter shift. Simulation of different isocenter shifts in all 3 directions showed that the isocentric shifts along the posterior direction had a very significant effect on the dose to the heart, IL, CLL, and CLB, which was followed by the lateral direction. The setup error in isocenter should be strictly kept below 3 mm. The study shows that isocenter verification in the case of tangential fields should be performed to reduce future complications to adjacent normal tissues.« less
Economic impact of medication error: a systematic review.
Walsh, Elaine K; Hansen, Christina Raae; Sahm, Laura J; Kearney, Patricia M; Doherty, Edel; Bradley, Colin P
2017-05-01
Medication error is a significant source of morbidity and mortality among patients. Clinical and cost-effectiveness evidence are required for the implementation of quality of care interventions. Reduction of error-related cost is a key potential benefit of interventions addressing medication error. The aim of this review was to describe and quantify the economic burden associated with medication error. PubMed, Cochrane, Embase, CINAHL, EconLit, ABI/INFORM, Business Source Complete were searched. Studies published 2004-2016 assessing the economic impact of medication error were included. Cost values were expressed in Euro 2015. A narrative synthesis was performed. A total of 4572 articles were identified from database searching, and 16 were included in the review. One study met all applicable quality criteria. Fifteen studies expressed economic impact in monetary terms. Mean cost per error per study ranged from €2.58 to €111 727.08. Healthcare costs were used to measure economic impact in 15 of the included studies with one study measuring litigation costs. Four studies included costs incurred in primary care with the remaining 12 measuring hospital costs. Five studies looked at general medication error in a general population with 11 studies reporting the economic impact of an individual type of medication error or error within a specific patient population. Considerable variability existed between studies in terms of financial cost, patients, settings and errors included. Many were of poor quality. Assessment of economic impact was conducted predominantly in the hospital setting with little assessment of primary care impact. Limited parameters were used to establish economic impact. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Detection of IMRT delivery errors based on a simple constancy check of transit dose by using an EPID
NASA Astrophysics Data System (ADS)
Baek, Tae Seong; Chung, Eun Ji; Son, Jaeman; Yoon, Myonggeun
2015-11-01
Beam delivery errors during intensity modulated radiotherapy (IMRT) were detected based on a simple constancy check of the transit dose by using an electronic portal imaging device (EPID). Twenty-one IMRT plans were selected from various treatment sites, and the transit doses during treatment were measured by using an EPID. Transit doses were measured 11 times for each course of treatment, and the constancy check was based on gamma index (3%/3 mm) comparisons between a reference dose map (the first measured transit dose) and test dose maps (the following ten measured dose maps). In a simulation using an anthropomorphic phantom, the average passing rate of the tested transit dose was 100% for three representative treatment sites (head & neck, chest, and pelvis), indicating that IMRT was highly constant for normal beam delivery. The average passing rate of the transit dose for 1224 IMRT fields from 21 actual patients was 97.6% ± 2.5%, with the lower rate possibly being due to inaccuracies of patient positioning or anatomic changes. An EPIDbased simple constancy check may provide information about IMRT beam delivery errors during treatment.
Evaluation of causes and frequency of medication errors during information technology downtime.
Hanuscak, Tara L; Szeinbach, Sheryl L; Seoane-Vazquez, Enrique; Reichert, Brendan J; McCluskey, Charles F
2009-06-15
The causes and frequency of medication errors occurring during information technology downtime were evaluated. Individuals from a convenience sample of 78 hospitals who were directly responsible for supporting and maintaining clinical information systems (CISs) and automated dispensing systems (ADSs) were surveyed using an online tool between February 2007 and May 2007 to determine if medication errors were reported during periods of system downtime. The errors were classified using the National Coordinating Council for Medication Error Reporting and Prevention severity scoring index. The percentage of respondents reporting downtime was estimated. Of the 78 eligible hospitals, 32 respondents with CIS and ADS responsibilities completed the online survey for a response rate of 41%. For computerized prescriber order entry, patch installations and system upgrades caused an average downtime of 57% over a 12-month period. Lost interface and interface malfunction were reported for centralized and decentralized ADSs, with an average downtime response of 34% and 29%, respectively. The average downtime response was 31% for software malfunctions linked to clinical decision-support systems. Although patient harm did not result from 30 (54%) medication errors, the potential for harm was present for 9 (16%) of these errors. Medication errors occurred during CIS and ADS downtime despite the availability of backup systems and standard protocols to handle periods of system downtime. Efforts should be directed to reduce the frequency and length of down-time in order to minimize medication errors during such downtime.
[Responsibility due to medication errors in France: a study based on SHAM insurance data].
Theissen, A; Orban, J-C; Fuz, F; Guerin, J-P; Flavin, P; Albertini, S; Maricic, S; Saquet, D; Niccolai, P
2015-03-01
The safe medication practices at the hospital constitute a major public health problem. Drug supply chain is a complex process, potentially source of errors and damages for the patient. SHAM insurances are the biggest French provider of medical liability insurances and a relevant source of data on the health care complications. The main objective of the study was to analyze the type and cause of medication errors declared to SHAM and having led to a conviction by a court. We did a retrospective study on insurance claims provided by SHAM insurances with a medication error and leading to a condemnation over a 6-year period (between 2005 and 2010). Thirty-one cases were analysed, 21 for scheduled activity and 10 for emergency activity. Consequences of claims were mostly serious (12 deaths, 14 serious complications, 5 simple complications). The types of medication errors were a drug monitoring error (11 cases), an administration error (5 cases), an overdose (6 cases), an allergy (4 cases), a contraindication (3 cases) and an omission (2 cases). Intravenous route of administration was involved in 19 of 31 cases (61%). The causes identified by the court expert were an error related to service organization (11), an error related to medical practice (11) or nursing practice (13). Only one claim was due to the hospital pharmacy. The claim related to drug supply chain is infrequent but potentially serious. These data should help strengthen quality approach in risk management. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Physician assistants and the disclosure of medical error.
Brock, Douglas M; Quella, Alicia; Lipira, Lauren; Lu, Dave W; Gallagher, Thomas H
2014-06-01
Evolving state law, professional societies, and national guidelines, including those of the American Medical Association and Joint Commission, recommend that patients receive transparent communication when a medical error occurs. Recommendations for error disclosure typically consist of an explanation that an error has occurred, delivery of an explicit apology, an explanation of the facts around the event, its medical ramifications and how care will be managed, and a description of how similar errors will be prevented in the future. Although error disclosure is widely endorsed in the medical and nursing literature, there is little discussion of the unique role that the physician assistant (PA) might play in these interactions. PAs are trained in the medical model and technically practice under the supervision of a physician. They are also commonly integrated into interprofessional health care teams in surgical and urgent care settings. PA practice is characterized by widely varying degrees of provider autonomy. How PAs should collaborate with physicians in sensitive error disclosure conversations with patients is unclear. With the number of practicing PAs growing rapidly in nearly all domains of medicine, their role in the error disclosure process warrants exploration. The authors call for educational societies and accrediting agencies to support policy to establish guidelines for PA disclosure of error. They encourage medical and PA researchers to explore and report best-practice disclosure roles for PAs. Finally, they recommend that PA educational programs implement trainings in disclosure skills, and hospitals and supervising physicians provide and support training for practicing PAs.
Safety Profile of Cough and Cold Medication Use in Pediatrics.
Green, Jody L; Wang, George Sam; Reynolds, Kate M; Banner, William; Bond, G Randall; Kauffman, Ralph E; Palmer, Robert B; Paul, Ian M; Dart, Richard C
2017-06-01
The safety of cough and cold medication (CCM) use in children has been questioned. We describe the safety profile of CCMs in children <12 years of age from a multisystem surveillance program. Cases with adverse events (AEs) after ingestion of at least 1 index CCM ingredient (brompheniramine, chlorpheniramine, dextromethorphan, diphenhydramine, doxylamine, guaifenesin, phenylephrine, and pseudoephedrine) in children <12 years of age were collected from 5 data sources. An expert panel determined relatedness, dose, intent, and risk factors. Case characteristics and AEs are described. Of the 4202 cases reviewed, 3251 (77.4%) were determined to be at least potentially related to a CCM, with accidental unsupervised ingestions (67.1%) and medication errors (13.0%) the most common exposure types. Liquid (67.3%), pediatric (75.5%), and single-ingredient (77.5%) formulations were most commonly involved. AEs occurring in >20% of all cases included tachycardia, somnolence, hallucinations, ataxia, mydriasis, and agitation. Twenty cases (0.6%) resulted in death; most were in children <2 years of age (70.0%) and none involved a therapeutic dose. The overall reported AE rate was 0.573 cases per 1 million units (ie, tablets, gelatin capsules, or liquid equivalent) sold (95% confidence interval, 0.553-0.593) or 1 case per 1.75 million units. The rate of AEs associated with CCMs in children was low. Fatalities occurred even less frequently. No fatality involved a therapeutic dose. Accidental unsupervised ingestions were the most common exposure types and single-ingredient, pediatric liquid formulations were the most commonly reported products. These characteristics present an opportunity for targeted prevention efforts. Copyright © 2017 by the American Academy of Pediatrics.
Perceived barriers to medical-error reporting: an exploratory investigation.
Uribe, Claudia L; Schweikhart, Sharon B; Pathak, Dev S; Dow, Merrell; Marsh, Gail B
2002-01-01
Medical-error reporting is an essential component for patient safety enhancement. Unfortunately, medical errors are largely underreported across healthcare institutions. This problem can be attributed to different factors and barriers present at organizational and individual levels that ultimately prevent individuals from generating the report. This study explored the factors that affect medical-error reporting among physicians and nurses at a large academic medical center located in the midwest United States. A nominal group session was conducted to identify the most relevant factors that act as barriers for error reporting. These factors were then used to design a questionnaire that explored the likelihood of the factors to act as barriers and their likelihood to be modified. Using these two parameters, the results were analyzed and combined into a Factor Relevance Matrix. The matrix identifies the factors for which immediate actions should be undertaken to improve medical-error reporting (immediate action factors). It also identifies factors that require long-term strategies (long-term strategy factors) as well as factors that the organization should be aware of but that are of lower priority (awareness factors). The strategies outlined in this study may assist healthcare organizations in improving medical-error reporting, as part of the efforts toward patient-safety enhancement. Although factors affecting medical-error reporting may vary between different organizations, the process used in identifying the factors and the Factor Relevance Matrix developed in this study are easily adaptable to any organizational setting.
Total Dose Effects on Error Rates in Linear Bipolar Systems
NASA Technical Reports Server (NTRS)
Buchner, Stephen; McMorrow, Dale; Bernard, Muriel; Roche, Nicholas; Dusseau, Laurent
2007-01-01
The shapes of single event transients in linear bipolar circuits are distorted by exposure to total ionizing dose radiation. Some transients become broader and others become narrower. Such distortions may affect SET system error rates in a radiation environment. If the transients are broadened by TID, the error rate could increase during the course of a mission, a possibility that has implications for hardness assurance.
Preventable Medical Errors Driven Modeling of Medical Best Practice Guidance Systems.
Ou, Andrew Y-Z; Jiang, Yu; Wu, Po-Liang; Sha, Lui; Berlin, Richard B
2017-01-01
In a medical environment such as Intensive Care Unit, there are many possible reasons to cause errors, and one important reason is the effect of human intellectual tasks. When designing an interactive healthcare system such as medical Cyber-Physical-Human Systems (CPHSystems), it is important to consider whether the system design can mitigate the errors caused by these tasks or not. In this paper, we first introduce five categories of generic intellectual tasks of humans, where tasks among each category may lead to potential medical errors. Then, we present an integrated modeling framework to model a medical CPHSystem and use UPPAAL as the foundation to integrate and verify the whole medical CPHSystem design models. With a verified and comprehensive model capturing the human intellectual tasks effects, we can design a more accurate and acceptable system. We use a cardiac arrest resuscitation guidance and navigation system (CAR-GNSystem) for such medical CPHSystem modeling. Experimental results show that the CPHSystem models help determine system design flaws and can mitigate the potential medical errors caused by the human intellectual tasks.
Stultz, Jeremy S; Nahata, Milap C
2015-07-01
Information technology (IT) has the potential to prevent medication errors. While many studies have analyzed specific IT technologies and preventable adverse drug events, no studies have identified risk factors for errors still occurring that are not preventable by IT. The objective of this study was to categorize reported or trigger tool-identified errors and adverse events (AEs) at a pediatric tertiary care institution. Also, we sought to identify medication errors preventable by IT, determine why IT-preventable errors occurred, and to identify risk factors for errors that were not preventable by IT. This was a retrospective analysis of voluntarily reported or trigger tool-identified errors and AEs occurring from 1 July 2011 to 30 June 2012. Medication errors reaching the patients were categorized based on the origin, severity, and location of the error, the month in which they occurred, and the age of the patient involved. Error characteristics were included in a multivariable logistic regression model to determine independent risk factors for errors occurring that were not preventable by IT. A medication error was defined as a medication-related failure of a planned action to be completed as intended or the use of a wrong plan to achieve an aim. An IT-preventable error was defined as having an IT system in place to aid in prevention of the error at the phase and location of its origin. There were 936 medication errors (identified by voluntarily reporting or a trigger tool system) included and analyzed. Drug administration errors were identified most frequently (53.4% ), but prescribing errors most frequently caused harm (47.2 % of harmful errors). There were 470 (50.2 %) errors that were IT preventable at their origin, including 155 due to IT system bypasses, 103 due to insensitivity of IT alerting systems, and 47 with IT alert overrides. Dispensing, administration, and documentation errors had higher odds than prescribing errors for being not preventable by IT [odds ratio (OR) 8.0, 95 % CI 4.4-14.6; OR 2.4, 95 % CI 1.7-3.7; and OR 6.7, 95 % CI 3.3-14.5, respectively; all p < 0.001). Errors occurring in the operating room and in the outpatient setting had higher odds than intensive care units for being not preventable by IT (OR 10.4, 95 % CI 4.0-27.2, and OR 2.6, 95 % CI 1.3-5.0, respectively; all p ≤ 0.004). Despite extensive IT implementation at the studied institution, approximately one-half of the medication errors identified by voluntarily reporting or a trigger tool system were not preventable by the utilized IT systems. Inappropriate use of IT systems was a common cause of errors. The identified risk factors represent areas where IT safety features were lacking.
Nowak, Michał S; Goś, Roman; Smigielski, Janusz
2008-01-01
To determine the prevalence of refractive errors in population. A retrospective review of medical examinations for entry to the military service from The Area Military Medical Commission in Lodz. Ophthalmic examinations were performed. We used statistic analysis to review the results. Statistic analysis revealed that refractive errors occurred in 21.68% of the population. The most commen refractive error was myopia. 1) The most commen ocular diseases are refractive errors, especially myopia (21.68% in total). 2) Refractive surgery and contact lenses should be allowed as the possible correction of refractive errors for military service.
Gilbar, Peter; Chambers, Carole R; Larizza, Maria
2015-02-01
The risk of medication errors with vincristine administration is well documented. Our objective was to ascertain how vincristine is administered worldwide and determine what strategies for preventing the accidental intrathecal administration of vincristine are in place. A survey, comprising 28 questions, was distributed to 363 International Society of Oncology Pharmacy Practitioners members from 42 countries via email. Questions were asked on methods of vincristine administration, intrathecal drug administration and strategies used to prevent medication errors. A reminder was sent and the survey was available on the International Society of Oncology Pharmacy Practitioners website. Only one survey per institution was requested. In all, 62 responses from 15 countries were received, with the majority from Australia. Vincristine was dispensed in mini-bags in 77.4% of centres, though some also used syringes. Syringes were used in 31.1% of centres, with half these doses prepared undiluted. Administration took 5 to 15 minutes in most centres (78.8%). The most common reasons for still using syringes were perceived risk of extravasation and faster infusion time. Despite numerous vincristine administrations, extravasation was very rare. Other recommended strategies for error prevention were in use in the majority of centres. Comparisons with three previous surveys are difficult as the majority of respondents in those studies were from the USA. A number of areas appear to have improved, particularly the preparation of vincristine in mini-bags, but they are far from perfect. Deaths continue to occur following accidental intrathecal administration of vincristine. International Society of Oncology Pharmacy Practitioner members are urged to lead the way in incorporating strategies for prevention into institutions worldwide. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Furmaga, Jakub; Wax, Paul; Kleinschmidt, Kurt
2015-09-01
Intravenous N-acetylcysteine (NAC) causes few adverse drug events, with mild anaphylactoid reactions being the most common. Hyponatremia as a complication of hypoosmolar NAC solution has been reported. We describe how a locally constructed electronic medical record (EMR) order set for IV NAC resulted in a seizure from hyponatremia due to excess free water administration. A 13-month-old female with no past medical history presented to a hospital after ingesting an unknown number of acetaminophen 500 mg tablets. The 4-h acetaminophen concentration was 343 mcg/mL, and she was started on IV NAC. 8.2 h into her 21-h IV NAC protocol, she developed a tonic-clonic seizure. Repeat serum sodium was 124 mEq/L, a decrease from 142 mEq/L at the time of admission. She was treated with hypertonic saline, lorazepam, and levetiracetam and had no further seizures. A brain MRI and EEG were both normal. After the seizure was stabilized, the providers noticed that the patient had receive a total of 900 mL of D5W (112.5 mL/kg) in the first 9 h of hospitalization. This was caused by a poorly constructed, restrictive, EMR order set that did not allow customization of the IV NAC preparation. Because the 21-h IV NAC administration involves preparation of 3 different doses infused over 3 different time intervals, an order set was developed to reduce ordering errors. However, error in its construction caused the pharmacist to prepare a solution containing too much free water, decreasing patient's intravascular sodium and resulting in a seizure. The purposes of our case report were to highlight the dangers of overreliance on EMR order sets and to recognize hyponatremic seizures as an adverse reaction of an inappropriately prepared IV NAC.
Ni, Hsing-Chang; Hwang Gu, Shoou-Lian; Lin, Hsiang-Yuan; Lin, Yu-Ju; Yang, Li-Kuang; Huang, Hui-Chun; Gau, Susan Shur-Fen
2016-05-01
Intra-individual variability in reaction time (IIV-RT) is common in individuals with attention-deficit/hyperactivity disorder (ADHD). It can be improved by stimulants. However, the effects of atomoxetine on IIV-RT are inconclusive. We aimed to investigate the effects of atomoxetine on IIV-RT, and directly compared its efficacy with methylphenidate in adults with ADHD. An 8-10 week, open-label, head-to-head, randomized clinical trial was conducted in 52 drug-naïve adults with ADHD, who were randomly assigned to two treatment groups: immediate-release methylphenidate (n=26) thrice daily (10-20 mg per dose) and atomoxetine once daily (n=26) (0.5-1.2 mg/kg/day). IIV-RT, derived from the Conners' continuous performance test (CCPT), was represented by the Gaussian (reaction time standard error, RTSE) and ex-Gaussian models (sigma and tau). Other neuropsychological functions, including response errors and mean of reaction time, were also measured. Participants received CCPT assessments at baseline and week 8-10 (60.4±6.3 days). We found comparable improvements in performances of CCPT between the immediate-release methylphenidate- and atomoxetine-treated groups. Both medications significantly improved IIV-RT in terms of reducing tau values with comparable efficacy. In addition, both medications significantly improved inhibitory control by reducing commission errors. Our results provide evidence to support that atomoxetine could improve IIV-RT and inhibitory control, of comparable efficacy with immediate-release methylphenidate, in drug-naïve adults with ADHD. Shared and unique mechanisms underpinning these medication effects on IIV-RT awaits further investigation. © The Author(s) 2016.
2011 drug packaging review: too many dangers and too many patients overlooked.
2012-05-01
Every year, Prescrire's analysis of drug packaging confirms the importance of taking packaging into account in assessing a drug's harm-benefit balance. Safe, tried and true options are available, yet the quality of most of the drug packaging Prescrire examined in 2011 left much to be desired. Few of the packaging items examined help prevent medication errors and many actually increase the risks: misleading and confusing labelling, dosing devices that create a risk of overdose, bottles without a child-proof cap, and inadequate or dangerous patient information leaflets. Umbrella brands continue to expand and are a potential source of medication errors. Some patients are at greater risk: the patient leaflets for NSAIDs endanger pregnant women and their unborn babies; children are insufficiently protected by paediatric packaging and are at risk due to the lack of child-proof caps on too many bottles. The raft of regulatory measures taken by the French drug regulatory agency (Afssaps) in the aftermath of the Mediator disaster overlooked the importance of packaging. Until drug regulatory agencies tackle the vast issue of drug packaging, it is up to healthcare professionals to protect patients from harm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sayah, N; Weiss, E; Watkins, W
Purpose: To evaluate the dose-mapping error (DME) inherent to conventional dose-mapping algorithms as a function of dose-matrix resolution. Methods: As DME has been reported to be greatest where dose-gradients overlap tissue-density gradients, non-clinical 66 Gy IMRT plans were generated for 11 lung patients with the target edge defined as the maximum 3D density gradient on the 0% (end of inhale) breathing phase. Post-optimization, Beams were copied to 9 breathing phases. Monte Carlo dose computed (with 2*2*2 mm{sup 3} resolution) on all 10 breathing phases was deformably mapped to phase 0% using the Monte Carlo energy-transfer method with congruent mass-mapping (EMCM);more » an externally implemented tri-linear interpolation method with voxel sub-division; Pinnacle’s internal (tri-linear) method; and a post-processing energy-mass voxel-warping method (dTransform). All methods used the same base displacement-vector-field (or it’s pseudo-inverse as appropriate) for the dose mapping. Mapping was also performed at 4*4*4 mm{sup 3} by merging adjacent dose voxels. Results: Using EMCM as the reference standard, no clinically significant (>1 Gy) DMEs were found for the mean lung dose (MLD), lung V20Gy, or esophagus dose-volume indices, although MLD and V20Gy were statistically different (2*2*2 mm{sup 3}). Pinnacle-to-EMCM target D98% DMEs of 4.4 and 1.2 Gy were observed ( 2*2*2 mm{sup 3}). However dTransform, which like EMCM conserves integral dose, had DME >1 Gy for one case. The root mean square RMS of the DME for the tri-linear-to- EMCM methods was lower for the smaller voxel volume for the tumor 4D-D98%, lung V20Gy, and cord D1%. Conclusion: When tissue gradients overlap with dose gradients, organs-at-risk DME was statistically significant but not clinically significant. Target-D98%-DME was deemed clinically significant for 2/11 patients (2*2*2 mm{sup 3}). Since tri-linear RMS-DME between EMCM and tri-linear was reduced at 2*2*2 mm{sup 3}, use of this resolution is recommended for dose mapping. Interpolative dose methods are sufficiently accurate for the majority of cases. J.V. Siebers receives funding support from Varian Medical Systems.« less
The approach of Bayesian model indicates media awareness of medical errors
NASA Astrophysics Data System (ADS)
Ravichandran, K.; Arulchelvan, S.
2016-06-01
This research study brings out the factors behind the increase in medical malpractices in the Indian subcontinent in the present day environment and impacts of television media awareness towards it. Increased media reporting of medical malpractices and errors lead to hospitals taking corrective action and improve the quality of medical services that they provide. The model of Cultivation Theory can be used to measure the influence of media in creating awareness of medical errors. The patient's perceptions of various errors rendered by the medical industry from different parts of India were taken up for this study. Bayesian method was used for data analysis and it gives absolute values to indicate satisfaction of the recommended values. To find out the impact of maintaining medical records of a family online by the family doctor in reducing medical malpractices which creates the importance of service quality in medical industry through the ICT.
Factors effective on medication errors: A nursing view.
Shahrokhi, Akram; Ebrahimpour, Fatemeh; Ghodousi, Arash
2013-01-01
Medication errors are the most common medical errors, which may result in some complications for patients. This study was carried out to investigate what influence medication errors by nurses from their viewpoint. In this descriptive study, 150 nurses who were working in Qazvin Medical University teaching hospitals were selected by proportional random sampling, and data were collected by means of a researcher-made questionnaire including demographic attributes (age, gender, working experience,…), and contributing factors in medication errors (in three categories including nurse-related, management-related, and environment-related factors). The mean age of the participant nurses was 30.7 ± 6.5 years. Most of them (87.1%) were female with a Bachelor of Sciences degree (86.7%) in nursing. The mean of their overtime working was 64.8 ± 38 h/month. The results showed that the nurse-related factors are the most effective factors (55.44 ± 9.14) while the factors related to the management system (52.84 ± 11.24) and the ward environment (44.0 ± 10.89) are respectively less effective. The difference between these three groups was significant (P = 0.000). In each aforementioned category, the most effective factor on medication error (ranked from the most effective to the least effective) were as follow: The nurse's inadequate attention (98.7%), the errors occurring in the transfer of medication orders from the patient's file to kardex (96.6%) and the ward's heavy workload (86.7%). In this study nurse-related factors were the most effective factors on medication errors, but nurses are one of the members of health-care providing team, so their performance must be considered in the context of the health-care system like work force condition, rules and regulations, drug manufacturing that might impact nurses performance, so it could not be possible to prevent medication errors without paying attention to our health-care system in a holistic approach.
Factors effective on medication errors: A nursing view
Shahrokhi, Akram; Ebrahimpour, Fatemeh; Ghodousi, Arash
2013-01-01
Objective: Medication errors are the most common medical errors, which may result in some complications for patients. This study was carried out to investigate what influence medication errors by nurses from their viewpoint. Methods: In this descriptive study, 150 nurses who were working in Qazvin Medical University teaching hospitals were selected by proportional random sampling, and data were collected by means of a researcher-made questionnaire including demographic attributes (age, gender, working experience,…), and contributing factors in medication errors (in three categories including nurse-related, management-related, and environment-related factors). Findings: The mean age of the participant nurses was 30.7 ± 6.5 years. Most of them (87.1%) were female with a Bachelor of Sciences degree (86.7%) in nursing. The mean of their overtime working was 64.8 ± 38 h/month. The results showed that the nurse-related factors are the most effective factors (55.44 ± 9.14) while the factors related to the management system (52.84 ± 11.24) and the ward environment (44.0 ± 10.89) are respectively less effective. The difference between these three groups was significant (P = 0.000). In each aforementioned category, the most effective factor on medication error (ranked from the most effective to the least effective) were as follow: The nurse's inadequate attention (98.7%), the errors occurring in the transfer of medication orders from the patient's file to kardex (96.6%) and the ward's heavy workload (86.7%). Conclusion: In this study nurse-related factors were the most effective factors on medication errors, but nurses are one of the members of health-care providing team, so their performance must be considered in the context of the health-care system like work force condition, rules and regulations, drug manufacturing that might impact nurses performance, so it could not be possible to prevent medication errors without paying attention to our health-care system in a holistic approach. PMID:24991599
Military Interoperable Digital Hospital Testbed (MIDHT)
2015-12-01
and Analyze the resulting technological impact on medication errors, pharmacists ’ productivity, nurse satisfactions/workflow and patient...medication errors, pharmacists productivity, nurse satisfactions/workflow and patient satisfaction. 1.1.1 Pharmacy Robotics Implementation...1.2 Research and analyze the resulting technological impact on medication errors, pharmacist productivity, nurse satisfaction/workflow and patient
Kim, Myoung Soo
2012-08-01
The purpose of this cross-sectional study was to examine current status of IT-based medication error prevention system construction and the relationships among system construction, medication error management climate and perception for system use. The participants were 124 patient safety chief managers working for 124 hospitals with over 300 beds in Korea. The characteristics of the participants, construction status and perception of systems (electric pharmacopoeia, electric drug dosage calculation system, computer-based patient safety reporting and bar-code system) and medication error management climate were measured in this study. The data were collected between June and August 2011. Descriptive statistics, partial Pearson correlation and MANCOVA were used for data analysis. Electric pharmacopoeia were constructed in 67.7% of participating hospitals, computer-based patient safety reporting systems were constructed in 50.8%, electric drug dosage calculation systems were in use in 32.3%. Bar-code systems showed up the lowest construction rate at 16.1% of Korean hospitals. Higher rates of construction of IT-based medication error prevention systems resulted in greater safety and a more positive error management climate prevailed. The supportive strategies for improving perception for use of IT-based systems would add to system construction, and positive error management climate would be more easily promoted.
SU-E-T-484: In Vivo Dosimetry Tolerances in External Beam Fast Neutron Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, L; Gopan, O
Purpose: Optical stimulated luminescence (OSL) dosimetry with Landauer Al2O3:C nanodots was developed at our institution as a passive in vivo dosimetry (IVD) system for patients treated with fast neutron therapy. The purpose of this study was to establish clinically relevant tolerance limits for detecting treatment errors requiring further investigation. Methods: Tolerance levels were estimated by conducting a series of IVD expected dose calculations for square field sizes ranging between 2.8 and 28.8 cm. For each field size evaluated, doses were calculated for open and internal wedged fields with angles of 30°, 45°, or 60°. Theoretical errors were computed for variationsmore » of incorrect beam configurations. Dose errors, defined as the percent difference from the expected dose calculation, were measured with groups of three nanodots placed in a 30 x 30 cm solid water phantom, at beam isocenter (150 cm SAD, 1.7 cm Dmax). The tolerances were applied to IVD patient measurements. Results: The overall accuracy of the nanodot measurements is 2–3% for open fields. Measurement errors agreed with calculated errors to within 3%. Theoretical estimates of dosimetric errors showed that IVD measurements with OSL nanodots will detect the absence of an internal wedge or a wrong wedge angle. Incorrect nanodot placement on a wedged field is more likely to be caught if the offset is in the direction of the “toe” of the wedge where the dose difference in percentage is about 12%. Errors caused by an incorrect flattening filter size produced a 2% measurement error that is not detectable by IVD measurement alone. Conclusion: IVD with nanodots will detect treatment errors associated with the incorrect implementation of the internal wedge. The results of this study will streamline the physicists’ investigations in determining the root cause of an IVD reading that is out of normally accepted tolerances.« less
MO-FG-202-05: Identifying Treatment Planning System Errors in IROC-H Phantom Irradiations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerns, J; Followill, D; Howell, R
Purpose: Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Methods: Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015more » were recalculated using this TVS. Comparison of plan accuracy was evaluated by comparing the measured dose to the institution’s TPS dose as well as the TVS dose. In cases where the TVS was more accurate than the institution by an average of >2%, the institution was identified as having a non-negligible TPS error. Results: Of the ∼200 recalculated plans, the average improvement using the TVS was ∼0.1%; i.e. the recalculation, on average, slightly outperformed the institution’s TPS. Of all the recalculated phantoms, 20% were identified as having a non-negligible TPS error. Fourteen plans failed current IROC-H criteria; the average TVS improvement of the failing plans was ∼3% and 57% were found to have non-negligible TPS errors. Conclusion: IROC-H has developed an independent recalculation system to identify institutions that have considerable TPS errors. A large number of institutions were found to have non-negligible TPS errors. Even institutions that passed IROC-H criteria could be identified as having a TPS error. Resolution of such errors would improve dose delivery for a large number of IROC-H phantoms and ultimately, patients.« less
Technology utilization to prevent medication errors.
Forni, Allison; Chu, Hanh T; Fanikos, John
2010-01-01
Medication errors have been increasingly recognized as a major cause of iatrogenic illness and system-wide improvements have been the focus of prevention efforts. Critically ill patients are particularly vulnerable to injury resulting from medication errors because of the severity of illness, need for high risk medications with a narrow therapeutic index and frequent use of intravenous infusions. Health information technology has been identified as method to reduce medication errors as well as improve the efficiency and quality of care; however, few studies regarding the impact of health information technology have focused on patients in the intensive care unit. Computerized physician order entry and clinical decision support systems can play a crucial role in decreasing errors in the ordering stage of the medication use process through improving the completeness and legibility of orders, alerting physicians to medication allergies and drug interactions and providing a means for standardization of practice. Electronic surveillance, reminders and alerts identify patients susceptible to an adverse event, communicate critical changes in a patient's condition, and facilitate timely and appropriate treatment. Bar code technology, intravenous infusion safety systems, and electronic medication administration records can target prevention of errors in medication dispensing and administration where other technologies would not be able to intercept a preventable adverse event. Systems integration and compliance are vital components in the implementation of health information technology and achievement of a safe medication use process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, B; Kanal, K; Dickinson, R
2014-06-15
Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structuredmore » Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.« less
Robust optimization in lung treatment plans accounting for geometric uncertainty.
Zhang, Xin; Rong, Yi; Morrill, Steven; Fang, Jian; Narayanasamy, Ganesh; Galhardo, Edvaldo; Maraboyina, Sanjay; Croft, Christopher; Xia, Fen; Penagaricano, Jose
2018-05-01
Robust optimization generates scenario-based plans by a minimax optimization method to find optimal scenario for the trade-off between target coverage robustness and organ-at-risk (OAR) sparing. In this study, 20 lung cancer patients with tumors located at various anatomical regions within the lungs were selected and robust optimization photon treatment plans including intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were generated. The plan robustness was analyzed using perturbed doses with setup error boundary of ±3 mm in anterior/posterior (AP), ±3 mm in left/right (LR), and ±5 mm in inferior/superior (IS) directions from isocenter. Perturbed doses for D 99 , D 98 , and D 95 were computed from six shifted isocenter plans to evaluate plan robustness. Dosimetric study was performed to compare the internal target volume-based robust optimization plans (ITV-IMRT and ITV-VMAT) and conventional PTV margin-based plans (PTV-IMRT and PTV-VMAT). The dosimetric comparison parameters were: ITV target mean dose (D mean ), R 95 (D 95 /D prescription ), Paddick's conformity index (CI), homogeneity index (HI), monitor unit (MU), and OAR doses including lung (D mean , V 20 Gy and V 15 Gy ), chest wall, heart, esophagus, and maximum cord doses. A comparison of optimization results showed the robust optimization plan had better ITV dose coverage, better CI, worse HI, and lower OAR doses than conventional PTV margin-based plans. Plan robustness evaluation showed that the perturbed doses of D 99 , D 98 , and D 95 were all satisfied at least 99% of the ITV to received 95% of prescription doses. It was also observed that PTV margin-based plans had higher MU than robust optimization plans. The results also showed robust optimization can generate plans that offer increased OAR sparing, especially for normal lungs and OARs near or abutting the target. Weak correlation was found between normal lung dose and target size, and no other correlation was observed in this study. © 2018 University of Arkansas for Medical Sciences. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Eliminating US hospital medical errors.
Kumar, Sameer; Steinebach, Marc
2008-01-01
Healthcare costs in the USA have continued to rise steadily since the 1980s. Medical errors are one of the major causes of deaths and injuries of thousands of patients every year, contributing to soaring healthcare costs. The purpose of this study is to examine what has been done to deal with the medical-error problem in the last two decades and present a closed-loop mistake-proof operation system for surgery processes that would likely eliminate preventable medical errors. The design method used is a combination of creating a service blueprint, implementing the six sigma DMAIC cycle, developing cause-and-effect diagrams as well as devising poka-yokes in order to develop a robust surgery operation process for a typical US hospital. In the improve phase of the six sigma DMAIC cycle, a number of poka-yoke techniques are introduced to prevent typical medical errors (identified through cause-and-effect diagrams) that may occur in surgery operation processes in US hospitals. It is the authors' assertion that implementing the new service blueprint along with the poka-yokes, will likely result in the current medical error rate to significantly improve to the six-sigma level. Additionally, designing as many redundancies as possible in the delivery of care will help reduce medical errors. Primary healthcare providers should strongly consider investing in adequate doctor and nurse staffing, and improving their education related to the quality of service delivery to minimize clinical errors. This will lead to an increase in higher fixed costs, especially in the shorter time frame. This paper focuses additional attention needed to make a sound technical and business case for implementing six sigma tools to eliminate medical errors that will enable hospital managers to increase their hospital's profitability in the long run and also ensure patient safety.
Harada, Saki; Suzuki, Akio; Nishida, Shohei; Kobayashi, Ryo; Tamai, Sayuri; Kumada, Keisuke; Murakami, Nobuo; Itoh, Yoshinori
2017-06-01
Insulin is frequently used for glycemic control. Medication errors related to insulin are a common problem for medical institutions. Here, we prepared a standardized sliding scale insulin (SSI) order sheet and assessed the effect of its introduction. Observations before and after the introduction of the standardized SSI template were conducted at Gifu University Hospital. The incidence of medication errors, hyperglycemia, and hypoglycemia related to SSI were obtained from the electronic medical records. The introduction of the standardized SSI order sheet significantly reduced the incidence of medication errors related to SSI compared with that prior to its introduction (12/165 [7.3%] vs 4/159 [2.1%], P = .048). However, the incidence of hyperglycemia (≥250 mg/dL) and hypoglycemia (≤50 mg/dL) in patients who received SSI was not significantly different between the 2 groups. The introduction of the standardized SSI order sheet reduced the incidence of medication errors related to SSI. © 2016 John Wiley & Sons, Ltd.
Quality assurance of dynamic parameters in volumetric modulated arc therapy
Manikandan, A; Sarkar, B; Holla, R; Vivek, T R; Sujatha, N
2012-01-01
Objectives The purpose of this study was to demonstrate quality assurance checks for accuracy of gantry speed and position, dose rate and multileaf collimator (MLC) speed and position for a volumetric modulated arc treatment (VMAT) modality (Synergy® S; Elekta, Stockholm, Sweden), and to check that all the necessary variables and parameters were synchronous. Methods Three tests (for gantry position–dose delivery synchronisation, gantry speed–dose delivery synchronisation and MLC leaf speed and positions) were performed. Results The average error in gantry position was 0.5° and the average difference was 3 MU for a linear and a parabolic relationship between gantry position and delivered dose. In the third part of this test (sawtooth variation), the maximum difference was 9.3 MU, with a gantry position difference of 1.2°. In the sweeping field method test, a linear relationship was observed between recorded doses and distance from the central axis, as expected. In the open field method, errors were encountered at the beginning and at the end of the delivery arc, termed the “beginning” and “end” errors. For MLC position verification, the maximum error was −2.46 mm and the mean error was 0.0153 ±0.4668 mm, and 3.4% of leaves analysed showed errors of >±1 mm. Conclusion This experiment demonstrates that the variables and parameters of the Synergy® S are synchronous and that the system is suitable for delivering VMAT using a dynamic MLC. PMID:22745206
Gorgich, Enam Alhagh Charkhat; Barfroshan, Sanam; Ghoreishi, Gholamreza; Yaghoobi, Maryam
2016-01-01
Introduction and Aim: Medication errors as a serious problem in world and one of the most common medical errors that threaten patient safety and may lead to even death of them. The purpose of this study was to investigate the causes of medication errors and strategies to prevention of them from nurses and nursing student viewpoint. Materials & Methods: This cross-sectional descriptive study was conducted on 327 nursing staff of khatam-al-anbia hospital and 62 intern nursing students in nursing and midwifery school of Zahedan, Iran, enrolled through the availability sampling in 2015. The data were collected by the valid and reliable questionnaire. To analyze the data, descriptive statistics, T-test and ANOVA were applied by use of SPSS16 software. Findings: The results showed that the most common causes of medications errors in nursing were tiredness due increased workload (97.8%), and in nursing students were drug calculation, (77.4%). The most important way for prevention in nurses and nursing student opinion, was reducing the work pressure by increasing the personnel, proportional to the number and condition of patients and also creating a unit as medication calculation. Also there was a significant relationship between the type of ward and the mean of medication errors in two groups. Conclusion: Based on the results it is recommended that nurse-managers resolve the human resources problem, provide workshops and in-service education about preparing medications, side-effects of drugs and pharmacological knowledge. Using electronic medications cards is a measure which reduces medications errors. PMID:27045413
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Jiahua; Penfold, Scott N., E-mail: scott.penfold@adelaide.edu.au
Purpose: The accuracy of proton dose calculation is dependent on the ability to correctly characterize patient tissues with medical imaging. The most common method is to correlate computed tomography (CT) numbers obtained via single-energy CT (SECT) with proton stopping power ratio (SPR). CT numbers, however, cannot discriminate between a change in mass density and change in chemical composition of patient tissues. This limitation can have consequences on SPR calibration accuracy. Dual-energy CT (DECT) is receiving increasing interest as an alternative imaging modality for proton therapy treatment planning due to its ability to discriminate between changes in patient density and chemicalmore » composition. In the current work we use a phantom of known composition to demonstrate the dosimetric advantages of proton therapy treatment planning with DECT over SECT. Methods: A phantom of known composition was scanned with a clinical SECT radiotherapy CT-simulator. The phantom was rescanned at a lower X-ray tube potential to generate a complimentary DECT image set. A set of reference materials similar in composition to the phantom was used to perform a stoichiometric calibration of SECT CT number to proton SPRs. The same set of reference materials was used to perform a DECT stoichiometric calibration based on effective atomic number. The known composition of the phantom was used to assess the accuracy of SPR calibration with SECT and DECT. Intensity modulated proton therapy (IMPT) treatment plans were generated with the SECT and DECT image sets to assess the dosimetric effect of the imaging modality. Isodose difference maps and root mean square (RMS) error calculations were used to assess dose calculation accuracy. Results: SPR calculation accuracy was found to be superior, on average, with DECT relative to SECT. Maximum errors of 12.8% and 2.2% were found for SECT and DECT, respectively. Qualitative examination of dose difference maps clearly showed the dosimetric advantages of DECT imaging, compared to SECT imaging for IMPT dose calculation for the case investigated. Quantitatively, the maximum dose calculation error in the SECT plan was 7.8%, compared to a value of 1.4% in the DECT plan. When considering the high dose target region, the root mean square (RMS) error in dose calculation was 2.1% and 0.4% for SECT and DECT, respectively. Conclusions: DECT-based proton treatment planning in a commercial treatment planning system was successfully demonstrated for the first time. DECT is an attractive imaging modality for proton therapy treatment planning owing to its ability to characterize density and chemical composition of patient tissues. SECT and DECT scans of a phantom of known composition have been used to demonstrate the dosimetric advantages obtainable in proton therapy treatment planning with DECT over the current approach based on SECT.« less
In vivo dose verification method in catheter based high dose rate brachytherapy.
Jaselskė, Evelina; Adlienė, Diana; Rudžianskas, Viktoras; Urbonavičius, Benas Gabrielis; Inčiūra, Arturas
2017-12-01
In vivo dosimetry is a powerful tool for dose verification in radiotherapy. Its application in high dose rate (HDR) brachytherapy is usually limited to the estimation of gross errors, due to inability of the dosimetry system/ method to record non-uniform dose distribution in steep dose gradient fields close to the radioactive source. In vivo dose verification in interstitial catheter based HDR brachytherapy is crucial since the treatment is performed inserting radioactive source at the certain positions within the catheters that are pre-implanted into the tumour. We propose in vivo dose verification method for this type of brachytherapy treatment which is based on the comparison between experimentally measured and theoretical dose values calculated at well-defined locations corresponding dosemeter positions in the catheter. Dose measurements were performed using TLD 100-H rods (6 mm long, 1 mm diameter) inserted in a certain sequences into additionally pre-implanted dosimetry catheter. The adjustment of dosemeter positioning in the catheter was performed using reconstructed CT scans of patient with pre-implanted catheters. Doses to three Head&Neck and one Breast cancer patient have been measured during several randomly selected treatment fractions. It was found that the average experimental dose error varied from 4.02% to 12.93% during independent in vivo dosimetry control measurements for selected Head&Neck cancer patients and from 7.17% to 8.63% - for Breast cancer patient. Average experimental dose error was below the AAPM recommended margin of 20% and did not exceed the measurement uncertainty of 17.87% estimated for this type of dosemeters. Tendency of slightly increasing average dose error was observed in every following treatment fraction of the same patient. It was linked to the changes of theoretically estimated dosemeter positions due to the possible patient's organ movement between different treatment fractions, since catheter reconstruction was performed for the first treatment fraction only. These findings indicate potential for further average dose error reduction in catheter based brachytherapy by at least 2-3% in the case that catheter locations will be adjusted before each following treatment fraction, however it requires more detailed investigation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
SIMulation of Medication Error induced by Clinical Trial drug labeling: the SIMME-CT study.
Dollinger, Cecile; Schwiertz, Vérane; Sarfati, Laura; Gourc-Berthod, Chloé; Guédat, Marie-Gabrielle; Alloux, Céline; Vantard, Nicolas; Gauthier, Noémie; He, Sophie; Kiouris, Elena; Caffin, Anne-Gaelle; Bernard, Delphine; Ranchon, Florence; Rioufol, Catherine
2016-06-01
To assess the impact of investigational drug labels on the risk of medication error in drug dispensing. A simulation-based learning program focusing on investigational drug dispensing was conducted. The study was undertaken in an Investigational Drugs Dispensing Unit of a University Hospital of Lyon, France. Sixty-three pharmacy workers (pharmacists, residents, technicians or students) were enrolled. Ten risk factors were selected concerning label information or the risk of confusion with another clinical trial. Each risk factor was scored independently out of 5: the higher the score, the greater the risk of error. From 400 labels analyzed, two groups were selected for the dispensing simulation: 27 labels with high risk (score ≥3) and 27 with low risk (score ≤2). Each question in the learning program was displayed as a simulated clinical trial prescription. Medication error was defined as at least one erroneous answer (i.e. error in drug dispensing). For each question, response times were collected. High-risk investigational drug labels correlated with medication error and slower response time. Error rates were significantly 5.5-fold higher for high-risk series. Error frequency was not significantly affected by occupational category or experience in clinical trials. SIMME-CT is the first simulation-based learning tool to focus on investigational drug labels as a risk factor for medication error. SIMME-CT was also used as a training tool for staff involved in clinical research, to develop medication error risk awareness and to validate competence in continuing medical education. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.
Opioid errors in inpatient palliative care services: a retrospective review.
Heneka, Nicole; Shaw, Tim; Rowett, Debra; Lapkin, Samuel; Phillips, Jane L
2018-06-01
Opioids are a high-risk medicine frequently used to manage palliative patients' cancer-related pain and other symptoms. Despite the high volume of opioid use in inpatient palliative care services, and the potential for patient harm, few studies have focused on opioid errors in this population. To (i) identify the number of opioid errors reported by inpatient palliative care services, (ii) identify reported opioid error characteristics and (iii) determine the impact of opioid errors on palliative patient outcomes. A 24-month retrospective review of opioid errors reported in three inpatient palliative care services in one Australian state. Of the 55 opioid errors identified, 84% reached the patient. Most errors involved morphine (35%) or hydromorphone (29%). Opioid administration errors accounted for 76% of reported opioid errors, largely due to omitted dose (33%) or wrong dose (24%) errors. Patients were more likely to receive a lower dose of opioid than ordered as a direct result of an opioid error (57%), with errors adversely impacting pain and/or symptom management in 42% of patients. Half (53%) of the affected patients required additional treatment and/or care as a direct consequence of the opioid error. This retrospective review has provided valuable insights into the patterns and impact of opioid errors in inpatient palliative care services. Iatrogenic harm related to opioid underdosing errors contributed to palliative patients' unrelieved pain. Better understanding the factors that contribute to opioid errors and the role of safety culture in the palliative care service context warrants further investigation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Nurses' behaviors and visual scanning patterns may reduce patient identification errors.
Marquard, Jenna L; Henneman, Philip L; He, Ze; Jo, Junghee; Fisher, Donald L; Henneman, Elizabeth A
2011-09-01
Patient identification (ID) errors occurring during the medication administration process can be fatal. The aim of this study is to determine whether differences in nurses' behaviors and visual scanning patterns during the medication administration process influence their capacities to identify patient ID errors. Nurse participants (n = 20) administered medications to 3 patients in a simulated clinical setting, with 1 patient having an embedded ID error. Error-identifying nurses tended to complete more process steps in a similar amount of time than non-error-identifying nurses and tended to scan information across artifacts (e.g., ID band, patient chart, medication label) rather than fixating on several pieces of information on a single artifact before fixating on another artifact. Non-error-indentifying nurses tended to increase their durations of off-topic conversations-a type of process interruption-over the course of the trials; the difference between groups was significant in the trial with the embedded ID error. Error-identifying nurses tended to have their most fixations in a row on the patient's chart, whereas non-error-identifying nurses did not tend to have a single artifact on which they consistently fixated. Finally, error-identifying nurses tended to have predictable eye fixation sequences across artifacts, whereas non-error-identifying nurses tended to have seemingly random eye fixation sequences. This finding has implications for nurse training and the design of tools and technologies that support nurses as they complete the medication administration process. (c) 2011 APA, all rights reserved.
Making Residents Part of the Safety Culture: Improving Error Reporting and Reducing Harms.
Fox, Michael D; Bump, Gregory M; Butler, Gabriella A; Chen, Ling-Wan; Buchert, Andrew R
2017-01-30
Reporting medical errors is a focus of the patient safety movement. As frontline physicians, residents are optimally positioned to recognize errors and flaws in systems of care. Previous work highlights the difficulty of engaging residents in identification and/or reduction of medical errors and in integrating these trainees into their institutions' cultures of safety. The authors describe the implementation of a longitudinal, discipline-based, multifaceted curriculum to enhance the reporting of errors by pediatric residents at Children's Hospital of Pittsburgh of University of Pittsburgh Medical Center. The key elements of this curriculum included providing the necessary education to identify medical errors with an emphasis on systems-based causes, modeling of error reporting by faculty, and integrating error reporting and discussion into the residents' daily activities. The authors tracked monthly error reporting rates by residents and other health care professionals, in addition to serious harm event rates at the institution. The interventions resulted in significant increases in error reports filed by residents, from 3.6 to 37.8 per month over 4 years (P < 0.0001). This increase in resident error reporting correlated with a decline in serious harm events, from 15.0 to 8.1 per month over 4 years (P = 0.01). Integrating patient safety into the everyday resident responsibilities encourages frequent reporting and discussion of medical errors and leads to improvements in patient care. Multiple simultaneous interventions are essential to making residents part of the safety culture of their training hospitals.
Suffering in Silence: Medical Error and its Impact on Health Care Providers.
Robertson, Jennifer J; Long, Brit
2018-04-01
All humans are fallible. Because physicians are human, unintentional errors unfortunately occur. While unintentional medical errors have an impact on patients and their families, they may also contribute to adverse mental and emotional effects on the involved provider(s). These may include burnout, lack of concentration, poor work performance, posttraumatic stress disorder, depression, and even suicidality. The objectives of this article are to 1) discuss the impact medical error has on involved provider(s), 2) provide potential reasons why medical error can have a negative impact on provider mental health, and 3) suggest solutions for providers and health care organizations to recognize and mitigate the adverse effects medical error has on providers. Physicians and other providers may feel a variety of adverse emotions after medical error, including guilt, shame, anxiety, fear, and depression. It is thought that the pervasive culture of perfectionism and individual blame in medicine plays a considerable role toward these negative effects. In addition, studies have found that despite physicians' desire for support after medical error, many physicians feel a lack of personal and administrative support. This may further contribute to poor emotional well-being. Potential solutions in the literature are proposed, including provider counseling, learning from mistakes without fear of punishment, discussing mistakes with others, focusing on the system versus the individual, and emphasizing provider wellness. Much of the reviewed literature is limited in terms of an emergency medicine focus or even regarding physicians in general. In addition, most studies are survey- or interview-based, which limits objectivity. While additional, more objective research is needed in terms of mitigating the effects of error on physicians, this review may help provide insight and support for those who feel alone in their attempt to heal after being involved in an adverse medical event. Unintentional medical error will likely always be a part of the medical system. However, by focusing on provider as well as patient health, we may be able to foster resilience in providers and improve care for patients in healthy, safe, and constructive environments. Copyright © 2017 Elsevier Inc. All rights reserved.
Daupin, Johanne; Atkinson, Suzanne; Bédard, Pascal; Pelchat, Véronique; Lebel, Denis; Bussières, Jean-François
2016-12-01
The medication-use system in hospitals is very complex. To improve the health professionals' awareness of the risks of errors related to the medication-use system, a simulation of medication errors was created. The main objective was to assess the medical, nursing and pharmacy staffs' ability to identify errors related to the medication-use system using a simulation. The secondary objective was to assess their level of satisfaction. This descriptive cross-sectional study was conducted in a 500-bed mother-and-child university hospital. A multidisciplinary group set up 30 situations and replicated a patient room and a care unit pharmacy. All hospital staff, including nurses, physicians, pharmacists and pharmacy technicians, was invited. Participants had to detect if a situation contained an error and fill out a response grid. They also answered a satisfaction survey. The simulation was held during 100 hours. A total of 230 professionals visited the simulation, 207 handed in a response grid and 136 answered the satisfaction survey. The participants' overall rate of correct answers was 67.5% ± 13.3% (4073/6036). Among the least detected errors were situations involving a Y-site infusion incompatibility, an oral syringe preparation and the patient's identification. Participants mainly considered the simulation as effective in identifying incorrect practices (132/136, 97.8%) and relevant to their practice (129/136, 95.6%). Most of them (114/136; 84.4%) intended to change their practices in view of their exposure to the simulation. We implemented a realistic medication-use system errors simulation in a mother-child hospital, with a wide audience. This simulation was an effective, relevant and innovative tool to raise the health care professionals' awareness of critical processes. © 2016 John Wiley & Sons, Ltd.
Evaluate the ability of clinical decision support systems (CDSSs) to improve clinical practice.
Ajami, Sima; Amini, Fatemeh
2013-01-01
Prevalence of new diseases, medical science promotion and increase of referring to health care centers, provide a good situation for medical errors growth. Errors can involve medicines, surgery, diagnosis, equipment, or lab reports. Medical errors can occur anywhere in the health care system: In hospitals, clinics, surgery centers, doctors' offices, nursing homes, pharmacies, and patients' homes. According to the Institute of Medicine (IOM), 98,000 people die every year from preventable medical errors. In 2010 from all referred medical error records to Iran Legal Medicine Organization, 46/5% physician and medical team members were known as delinquent. One of new technologies that can reduce medical errors is clinical decision support systems (CDSSs). This study was unsystematic-review study. The literature was searched on evaluate the "ability of clinical decision support systems to improve clinical practice" with the help of library, books, conference proceedings, data bank, and also searches engines available at Google, Google scholar. For our searches, we employed the following keywords and their combinations: medical error, clinical decision support systems, Computer-Based Clinical Decision Support Systems, information technology, information system, health care quality, computer systems in the searching areas of title, keywords, abstract, and full text. In this study, more than 100 articles and reports were collected and 38 of them were selected based on their relevancy. The CDSSs are computer programs, designed for help to health care careers. These systems as a knowledge-based tool could help health care manager in analyze evaluation, improvement and selection of effective solutions in clinical decisions. Therefore, it has a main role in medical errors reduction. The aim of this study was to express ability of the CDSSs to improve