Sample records for double balloon endoscopy

  1. Multicenter comparison of double-balloon enteroscopy and spiral enteroscopy.

    PubMed

    Rahmi, Gabriel; Samaha, Elia; Vahedi, Kouroche; Ponchon, Thierry; Fumex, Fabien; Filoche, Bernard; Gay, Gerard; Delvaux, Michel; Lorenceau-Savale, Camille; Malamut, Georgia; Canard, Jean-Marc; Chatellier, Gilles; Cellier, Christophe

    2013-06-01

    Spiral enteroscopy is a novel technique for small bowel exploration. The aim of this study is to compare double-balloon and spiral enteroscopy in patients with suspected small bowel lesions. Patients with suspected small bowel lesion diagnosed by capsule endoscopy were prospectively included between September 2009 and December 2010 in five tertiary-care academic medical centers. After capsule endoscopy, 191 double-balloon enteroscopy and 50 spiral enteroscopies were performed. Indications were obscure gastrointestinal bleeding in 194 (80%) of cases. Lesions detected by capsule endoscopy were mainly angioectasia. Double-balloon and spiral enteroscopy resulted in finding one or more lesions in 70% and 75% of cases, respectively. The mean diagnosis procedure time and the average small bowel explored length during double-balloon and spiral enteroscopy were, respectively, 60 min (45-80) and 55 min (45-80) (P=0.74), and 200 cm (150-300) and 220 cm (200-300) (P=0.13). Treatment during double-balloon and spiral enteroscopy was possible in 66% and 70% of cases, respectively. There was no significant major procedure-related complication. Spiral enteroscopy appears as safe as double-balloon enteroscopy for small bowel exploration with a similar diagnostic and therapeutic yield. Comparison between the two procedures in terms of duration and length of small bowel explored is slightly in favor of spiral enteroscopy but not significantly. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  2. Non-steroidal anti-inflammatory drug-induced small bowel injuries identified by double-balloon endoscopy

    PubMed Central

    Hayashi, Yoshikazu; Yamamoto, Hironori; Kita, Hiroto; Sunada, Keijiro; Sato, Hiroyuki; Yano, Tomonori; Iwamoto, Michiko; Sekine, Yutaka; Miyata, Tomohiko; Kuno, Akiko; Iwaki, Takaaki; Kawamura, Yoshiyuki; Ajibe, Hironari; Ido, Kenichi; Sugano, Kentaro

    2005-01-01

    AIM: To clarify clinical features of the NSAID-induced small bowel lesions using a new method of endoscopy. METHODS: This is a retrospective study and we analyzed seven patients with small bowel lesions while taking NSAIDs among 61 patients who had undergone double-balloon endoscopy because of gastro-intestinal bleeding or anemia between September 2000 and March 2004, at Jichi Medical School Hospital in Japan. Neither conventional EGD nor colonoscopy revealed any lesions of potential bleeding sources including ulcerations. Double-balloon endoscopy was carried out from oral approach in three patients, from anal approach in three patients, and from both approaches in one patient. RESULTS: Ulcers or erosions were observed in the ileum in six patients and in the jejunum in one patient, respectively. The ulcers were multiple in all the patients with different features from tiny punched out ulcers to deep ulcerations with oozing hemorrhage or scar. All the patients recovered uneventfully and had full resolution of symptoms after suspension of the drug. CONCLUSION: NSAIDs can induce injuries in the small bowel even in patients without any lesions in both the stomach and colon. PMID:16097059

  3. Primary intestinal lymphangiectasia diagnosed by capsule endoscopy and double balloon enteroscopy

    PubMed Central

    Oh, Tak Geun; Chung, Joo Won; Kim, Hee Man; Han, Seok-Joo; Lee, Jin Sung; Park, Jung Yeob; Song, Si Young

    2011-01-01

    Primary intestinal lymphangiectasia (PIL) is a rare disorder characterized by dilated intestinal lymphatics and the development of protein-losing enteropathy. Patients with PIL develop hypoalbuminemia, hypocalcemia, lymphopenia and hypogammaglobulinemia, and present with bilateral lower limb edema, fatigue, abdominal pain and diarrhea. Endoscopy reveals diffusely elongated, circumferential and polypoid mucosae covered with whitish enlarged villi, all of which indicate intestinal lymphangiectasia. Diagnosis is confirmed by characteristic tissue pathology, which includes dilated intestinal lymphatics with diffusely swollen mucosa and enlarged villi. The prevalence of PIL has increased since the introduction of capsule endoscopy. The etiology and prevalence of PIL remain unknown. Some studies have reported that several genes and regulatory molecules for lymphangiogenesis are related to PIL. We report the case of a patient with PIL involving the entire small bowel that was confirmed by capsule endoscopy and double-balloon enteroscopy-guided tissue pathology who carried a deletion on chromosome 4q25. The relationship between this deletion on chromosome 4 and PIL remains to be investigated. PMID:22110841

  4. Duplication cyst of the small intestine found by double-balloon endoscopy: A case report

    PubMed Central

    Ogino, Haruei; Ochiai, Toshiaki; Nakamura, Norimoto; Yoshimura, Daisuke; Kabemura, Teppei; Kusumoto, Tetsuya; Matsuura, Hiroshi; Nakashima, Akihiko; Honda, Kuniomi; Nakamura, Kazuhiko

    2008-01-01

    A 35-year-old man was admitted due to bloody stool and anemia. The bleeding source could not be detected by esophagogastroduodenoscopy or colonoscopy. Double balloon endoscopy (DBE) revealed a diverticulum-like hole in which coagula stuck in the ileum at 1 meter on the oral side from the ileocecal valve. The adjacent mucosa just to the oral side of the hole was elevated like a submucosal tumor. The lesion was considered the source of bleeding and removed surgically. It was determined to be a cyst with an ileal structure on the mesenteric aspect accompanying gastric mucosa. The diagnosis was a duplication cyst of the ileum, which is a rare entity that can cause gastrointestinal bleeding. In the present case, DBE was used to find the hemorrhagic duplication cyst in the ileum. PMID:18609722

  5. Small bowel capsule endoscopy in 2007: Indications, risks and limitations

    PubMed Central

    Rondonotti, Emanuele; Villa, Federica; Mulder, Chris JJ; Jacobs, Maarten AJM; de Franchis, Roberto

    2007-01-01

    Capsule endoscopy has revoluzionized the study of the small bowel by providing a reliable method to evaluate, endoscopically, the entire small bowel. In the last six years several papers have been published exploring the possible role of this examination in different clinical conditions. At the present time capsule endoscopy is generally recommended as a third examination, after negative bidirectional endoscopy, in patients with obscure gastrointestinal bleeding. A growing body of evidence suggests also an important role for this examination in other clinical conditions such as Crohn’s disease, celiac disease, small bowel polyposis syndromes or small bowel tumors. The main complication of this examination is the retention of the device at the site of a previously unknown small bowel stricture. However there are also some other open issues mainly due to technical limitations of this tool (which is not driven from remote control, is unable to take biopsies, to insufflate air, to suck fluids or debris and sometimes to correctly size and locate lesions).The recently developed double balloon enteroscope, owing to its capability to explore a large part of the small bowel and to take targeted biopsies, although being invasive and time consuming, can overcome some limitations of capsule endoscopy. At the present time, in the majority of clinical conditions (i.e. obscure GI bleeding), the winning strategy seems to be to couple these two techniques to explore the small bowel in a painless, safe and complete way (with capsule endoscopy) and to define and treat the lesions identified (with double balloon enteroscopy). PMID:18069752

  6. Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval.

    PubMed

    Van Weyenberg, Stijn J B; Van Turenhout, Sietze T; Bouma, Gerd; Van Waesberghe, Jan Hein T M; Van der Peet, Donald L; Mulder, Chris J J; Jacobs, Maarten A J M

    2010-03-01

    Capsule retention in the small bowel is a known complication of small-bowel video capsule endoscopy. Surgery is the most frequently used method of capsule retrieval. To determine the incidence and causes of capsule retention and to describe double-balloon endoscopy (DBE) as the primary technique used for capsule retrieval. Retrospective analysis of all video capsule studies was performed at our center, and evaluation of the outcome of DBE was the first method used to retrieve entrapped video capsules. Tertiary referral center. A total of 904 patients who underwent small-bowel video capsule endoscopy. Capsule retrieval by DBE. The number of patients in whom capsule retention occurred and the number of patients in whom an entrapped capsule could be retrieved by using DBE. Capsule retention occurred in 8 patients (incidence 0.88%; 95% CI, 0.41%-1.80%) and caused acute small-bowel obstruction in 6 patients. All retained capsules were successfully removed during DBE. Five patients underwent elective surgery to treat the underlying cause of capsule retention. One patient required emergency surgery because of multiple small-bowel perforations. Retrospective design. In our series, the incidence of capsule retention was low. DBE is a reliable method for removing retained capsules and might prevent unnecessary surgery. If surgery is required, preoperative capsule retrieval allows preoperative diagnosis, adequate staging in case of malignancy, and optimal surgical planning. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  7. Patient burden and patient preference: comparing magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy.

    PubMed

    Wiarda, Bart M; Stolk, Mark; Heine, Dimitri G N; Mensink, Peter; Thieme, Mai E; Kuipers, Ernst J; Stoker, Jaap

    2013-03-01

    We aimed to prospectively determine patient burden and patient preference for magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy in patients with suspected or known Crohn's disease (CD) or occult gastrointestinal bleeding (OGIB).  Consecutive consenting patients with CD or OGIB underwent magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy. Capsule endoscopy was only performed if magnetic resonance enteroclysis showed no high-grade small bowel stenosis. Patient preference and burden was evaluated by means of standardized questionnaires at five moments in time. From January 2007 until March 2009, 76 patients were included (M/F 31/45; mean age 46.9 years; range 20.0-78.4 years): 38 patients with OGIB and 38 with suspected or known CD. Seventeen patients did not undergo capsule endoscopy because of high-grade stenosis. Ninety-five percent (344/363) of the questionnaires were suitable for evaluation. Capsule endoscopy was significantly favored over magnetic resonance enteroclysis and balloon-assisted enteroscopy with respect to bowel preparation, swallowing of the capsule (compared to insertion of the tube/scope), burden of the entire examination, duration and accordance with the pre-study information. Capsule endoscopy and magnetic resonance enteroclysis were significantly preferred over balloon-assisted enteroscopy for clarity of explanation of the examination, and magnetic resonance enteroclysis was significantly preferred over balloon-assisted enteroscopy for bowel preparation, painfulness and burden of the entire examination. Balloon-assisted enteroscopy was significantly favored over magnetic resonance enteroclysis for insertion of the scope and procedure duration. Pre- and post-study the order of preference was capsule endoscopy, magnetic resonance enteroclysis and balloon-assisted enteroscopy. Capsule endoscopy was preferred to magnetic resonance enteroclysis and balloon-assisted enteroscopy; it also had the lowest burden. Magnetic resonance enteroclysis was preferred over balloon-assisted enteroscopy for clarity of explanation of the examination, bowel preparation, painfulness and burden of the entire examination, and balloon-assisted enteroscopy over magnetic resonance enteroclysis for scope insertion and study duration. © 2012 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  8. Endoscopy in inflammatory bowel disease when and why

    PubMed Central

    Rameshshanker, Rajaratnam; Arebi, Naila

    2012-01-01

    Endoscopy plays an important role in the diagnosis and management of inflammatory bowel disease (IBD). It is useful to exclude other aetiologies, differentiate between ulcerative colitis (UC) and Crohn’s disease (CD), and define the extent and activity of inflammation. Ileocolonoscopy is used for monitoring of the disease, which in turn helps to optimize the management. It plays a key role in the surveillance of UC for dysplasia or neoplasia and assessment of post operative CD. Capsule endoscopy and double balloon enteroscopy are increasingly used in patients with CD. Therapeutic applications relate to stricture dilatation and dysplasia resection. The endoscopist’s role is vital in the overall management of IBD. PMID:22720120

  9. A case of penetration of the intestinal wall by a soft-shelled turtle bone successfully removed with double-balloon endoscopy.

    PubMed

    Sawada, Mizuho; Sekigawa, Kenichiro; Mitsui, Hiroshi; Kobayashi, Katsuya; Okubo, Masao; Yamaguchi, Hajime; Hashimoto, Naoaki

    2015-10-01

    A 62-year-old male was admitted to our hospital due to left lower abdominal pain. Three days before admission, he ate seafood in a Japanese restaurant. Two days before admission, he suffered from intermittent left lower abdominal pain. One day before admission, he developed a high fever and subsequently visited our hospital the following day. Localized tenderness and rebound pain were observed in the left lower abdomen, and C-reactive protein was elevated. Computed tomography revealed a linear high-density object in the distal portion of the small intestine accompanied by edema of the wall, suggesting penetration by something like a fishbone. On the ninth hospital day, double-balloon endoscopy was performed via the transanal route. Yellow foreign material was found in the ileum and was then successfully removed with biopsy forceps. The removed material measured 3 mm in width, 3 cm in length and was slightly curved. It proved to be a bone of the forefoot of a soft-shelled turtle, which had been included on the menu of the restaurant. The patient was completely cured and discharged on the 14th hospital day.

  10. Single- and double-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y plus hepaticojejunostomy anastomosis and Whipple resection.

    PubMed

    Itokawa, Fumihide; Itoi, Takao; Ishii, Kentaro; Sofuni, Atsushi; Moriyasu, Fuminori

    2014-04-01

    In patients with Roux-en-Y hepaticojejunostomy (HJ with R-Y) and Whipple resection, endoscopic retrograde cholangiopancreatography (ERCP) can be challenging. We report our experience with ERCP using balloon-assisted enteroscopy (BAE) (BAE-ERCP) in patients with HJ with R-Y, and Whipple resection. BAE-ERCP procedures were carried out in 62 patients (HJ with R-Y:Whipple resection=34:28). Overall, the rates of reaching the anastomosis were 85.3% (29/34) in HJ with R-Y and 96.4% (27/28) in Whipple resection. In terms of HJ with R-Y, insertion success rate by standard single-balloon enteroscopy (SBE) was 89.3% (25/28). Insertion success rate by short BAE, including SBE and double-balloon enteroscopy (DBE), was 50% (3/6). There was a statistically significant difference of insertion success rate between standard long BE and short BE (P=0.021). However, in the Whipple patients, insertion success rate by standard and short SBE was 93.8% (15/16) and 91.7% (11/12), respectively. Initial insertion success rate by short BAE in Whipple patients was significantly higher than in HJ with R-Y (91.7% vs 50%, P=0.045). Therapeutic interventions included dilation of anastomosis stricture, stone extraction, endoscopic mechanical lithotripsy, biliary stent placement, stent extraction, endoscopic nasobiliary drainage, direct cholangioscopy, and electrohydraulic lithotripsy. Our HJ with R-Y series and Whipple series treatment success rate was 90% (18/20) and 95.0% (19/20), respectively. BAE-ERCP enabled ERCP to be carried out in patients with HJ. It is considered safe and feasible. Further experience and device improvement are needed. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  11. The financial impact of flipping the coin.

    PubMed

    Gonzalez, Katherine W; Reddy, Shiva R; Mundakkal, Angela A; St Peter, Shawn D

    2017-01-01

    Esophageal foreign body retrieval is typically performed by rigid or flexible esophagoscopy. Despite evidence supporting the efficacy and safety of balloon extraction, it is rarely performed. We sought to establish the financial benefits of this minimally invasive approach. A retrospective review of 241 children with esophageal coins between 2011 and 2013 was performed. Coins were removed via endoscopy or fluoroscopic-guided balloon retrieval. Timing, symptoms, facility cost, and patient charges were compared. Two hundred patients had attempted balloon retrieval with 80% success. Forty-one patients went directly for operative removal. Patients with respiratory difficulty (p=0.05), wheezing (p<0.01), or fever (p=0.03) were more often taken directly for endoscopic retrieval. The median cost and charges for attempted balloon extraction were $484 and $1647. The median cost and charges for primary endoscopy were $1834 and $6746. The median total cost and charges of attempted balloon extraction including ED, OR, transport, admission, and balloon retrieval were $1231 and $3539 versus $3615 and $12,204 in the primary endoscopy group (p<0.001, p<0.001). Seventeen percent of patients who underwent attempted balloon retrieval were admitted prior to removal compared to 76% who underwent primary endoscopy (p<0.001). Fluoroscopic guided balloon extraction of esophageal coins is a financially prudent choice which shortens hospital stay. III. Retrospective treatment and economic study. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Development of optical laser balloon and drainage from radiation vulcanized natural rubber latex

    NASA Astrophysics Data System (ADS)

    Shimamura, Yoshiyuki

    Rubber film made of radiation vulcanized natural rubber latex (RVNRL) has better transparency and lower toxicity compared with sulfur-vulcanized latex film. Optical laser balloon (optical endoscopical balloon) and drainage were developed by using RVNRL. An endoscope was equipped with a saline-filled latex rubber balloon at its tip to displace contaminating blood, bile, or gastric contents during operative portoscopy, biliary endoscopy, or upper gastrointestinal endoscopy. The transmission of Nd-Yag laser through the balloon is 98%, higher than the sulfur-vulcanized latex rubber (75%). High transparency of the drainage bag facilitated easy observation of discharged fluids without detaching the bag from the tube.

  13. Hookworm Infection: A Neglected Cause of Overt Obscure Gastrointestinal Bleeding.

    PubMed

    Wei, Kun-Yan; Yan, Qiong; Tang, Bo; Yang, Shi-Ming; Zhang, Peng-Bing; Deng, Ming-Ming; Lü, Mu-Han

    2017-08-01

    Hookworm infections are widely prevalent in tropical and subtropical areas, especially in low income regions. In the body, hookworms parasitize the proximal small intestine, leading to chronic intestinal hemorrhage and iron deficiency anemia. Occasionally, hookworms can cause overt gastrointestinal bleeding, but this is often ignored in heavily burdened individuals from endemic infectious areas. A total of 424 patients with overt obscure gastrointestinal bleeding were diagnosed by numerous blood tests or stool examinations as well as esophagogastroduodenoscopy, colonoscopy, capsule endoscopy or double-balloon enteroscopy. All of the patients lived in hookworm endemic areas and were not screened for hookworm infection using sensitive tests before the final diagnosis. The patients recovered after albendazole treatment, blood transfusion, and iron replacement, and none of the patients experienced recurrent bleeding in the follow-up. All the 31 patients were diagnosed with hookworm infections without other concomitant bleeding lesions, a rate of 7.3% (31/424). Seventeen out of 227 patients were diagnosed with hookworm infections in the capsule endoscopy (CE), and 14 out of 197 patients were diagnosed with hookworm infections in the double balloon enteroscopy (DBE). Hookworm infections can cause overt gastrointestinal bleeding and should be screened in patients with overt obscure gastrointestinal bleeding (OGIB) in endemic infectious areas with sensitive methods. Specifically, the examination of stool specimens is clinically warranted for most patients, and the proper examination for stool eggs relies on staff's communication.

  14. Review of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography using several endoscopic methods in patients with surgically altered gastrointestinal anatomy

    PubMed Central

    Shimatani, Masaaki; Takaoka, Makoto; Tokuhara, Mitsuo; Miyoshi, Hideaki; Ikeura, Tsukasa; Okazaki, Kazuichi

    2015-01-01

    The endoscopic approach for biliary diseases in patients with surgically altered gastrointestinal anatomy (SAGA) had been generally deemed impractical. However, it was radically made feasible by the introduction of double balloon endoscopy (DBE) that was originally developed for diagnosis and treatments for small-bowel diseases. Followed by the subsequent development of single-balloon endoscopy (SBE) and spiral endoscopy (SE), interventions using several endoscopes for biliary disease in patients with SAGA widely gained an acceptance as a new modality. Many studies have been made on this new technique. Yet, some problems are to be solved. For instance, the mutual unavailability among devices due to different working lengths and channels, and unestablished standardization of procedural techniques can be raised. Additionally, in an attempt to standardize endoscopic procedures, it is important to evaluate biliary cannulating methods by case with existence of papilla or not. A full comprehension of the features of respective scope types is also required. However there are not many papers written as a review. In our manuscript, we would like to evaluate and make a review of the present status of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography applying DBE, SBE and SE for biliary diseases in patients with SAGA for establishment of these modalities as a new technology and further improvement of the scopes and devices. PMID:26078830

  15. Indwelling esophageal balloon catheter for benign esophageal stenosis in infants and children.

    PubMed

    van der Zee, David; Hulsker, Caroline

    2014-04-01

    Balloon dilatation of benign esophageal strictures is an established mode of therapy in adults and children. There remains a group of patients with refractory stenosis despite dilatation at regular intervals. An indwelling balloon catheter may offer an alternative. This is a retrospective study of 19 children who underwent esophagoscopy between 2004 and 2012 with placement of an indwelling balloon catheter for refractory esophageal stenosis. Total number of endoscopies, number of endoscopies with indwelling balloon catheter, as well as complications, reoperations, and mortality due to use of the balloon catheter were studied. Patient age ranged from 4 weeks to 15 years. The indwelling balloon catheter was used to treat refractory stenosis after corrective surgery of long gap esophageal atresia (n = 5), esophageal atresia with distal fistula (n = 2), refractory esophageal stenosis due to caustic esophageal burns (n = 7), reflux (n = 2), and stenosis of unknown cause (n = 3). With the indwelling balloon catheter in place, the mean number of endoscopies equalled four. Complications were restenosis after a symptom-free period for which a new indwelling balloon catheter was necessary (n = 3). Two others needed two to five additional dilations: balloon leakage requiring replacement (n = 7 in 5 patients), sputum retention (n = 1), and dislodgement (n = 5 in 4 patients). More importantly, there was no mortality or the need for any patient to undergo a surgical resection. The indwelling balloon catheter is safe to use and can be used by parents at home. More importantly it obviates the need for rethoracotomy/-scopy or esophageal replacement.

  16. Ileal polypoid lymphangiectasia bleeding diagnosed and treated by double balloon enteroscopy

    PubMed Central

    Park, Min Seon; Lee, Beom Jae; Gu, Dae Hoe; Pyo, Jeung-Hui; Kim, Kyeong Jin; Lee, Yun Ho; Joo, Moon Kyung; Park, Jong-Jae; Kim, Jae Seon; Bak, Young-Tae

    2013-01-01

    Intestinal lymphangiectasia is a rare disease characterized by focal or diffuse dilated enteric lymphatics with impaired lymph drainage. It causes protein-losing enteropathy and may lead to gastrointestinal bleeding. Commonly, lymphangiectasia presents as whitish spots or specks. To our knowledge, small bowel bleeding resulting from polypoid intestinal lymphangiectasia has not been reported. Here, we report a rare case of active bleeding from the small bowel caused by polypoid lymphangiectasia with a review of the relevant literature. An 80-year-old woman was hospitalized for melena. Esophagogastroduodenoscopy could not identify the source of bleeding. Subsequent colonoscopy showed fresh bloody material gushing from the small bowel. An abdominal-pelvic contrast-enhanced computed tomography scan did not reveal any abnormal findings. Video capsule endoscopy showed evidence of active and recent bleeding in the ileum. To localize the bleeding site, we performed double balloon enteroscopy by the anal approach. A small, bleeding, polypoid lesion was found in the distal ileum and was successfully removed using endoscopic snare electrocautery. PMID:24363538

  17. Usefulness of positron emission tomography in primary intestinal follicular lymphoma

    PubMed Central

    Tari, Akira; Asaoku, Hideki; Kunihiro, Masaki; Tanaka, Shinji; Yoshino, Tadashi

    2013-01-01

    Double-balloon enteroscopy (DBE) and video capsule endoscopy are useful for the diagnosis of lymphoma in the small intestine. However, DBE cannot be safely performed in cases with passage disturbance due to wall thickening and stenosis. Additionally, video capsule endoscopy cannot be performed in such cases because of the risk of retention. Here, we report 4 cases of primary follicular lymphoma of the gastrointestinal tract that could be detected using 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (PET-CT). The endoscopic findings of these 4 cases included lesions with wall thickening, which comprised macroscopically clusters of nodules, dense clusters of whitish granules or small nodules, fold thickening and ulcers with irregular margins that occupied the whole lumen with edematous mucosa. All patients fulfilled the World Health Organization grade 1 criteria. 18F-fluorodeoxyglucose PET-CT can help predict the risks that may result from certain endoscopic examinations, such as DBE and video capsule endoscopy. PMID:23569346

  18. Double-balloon endoscopy for retrograde cholangiography in patients with choledochojejunostomy and Roux-en-Y reconstruction.

    PubMed

    Pohl, J; May, A; Aschmoneit, I; Ell, C

    2009-02-01

    Choledochojejunal anastomoses with Roux-en-Y reconstruction excludes the biliary tract from conventional endoscopic retrograde cholangiography (ERC) with standard endoscopes due to the length of the interposed small bowel segment. Double-balloon enteroscopy (DBE) facilitates deep insertion into the small bowel and may be used to perform ERC in these patients. In the present case series we report our experience with diagnostic and therapeutic double-balloon ERC in patients with choledochojejunostomy to a long Roux-en-Y loop previously unavailable for standard length endoscopes. Between December 2004 and May 2008 15 patients (mean age: 60.2 years) with choledochojejunal anastomosis underwent a total of 25 DBE-ERC procedures. Cannulation of the bile ducts was achieved in 22 / 25 procedures (84 %). Twenty-one therapeutic interventions, including stone removal, biliary duct dilation, stent placement and removal of previously placed stents were performed during 16 procedures in 8 patients. The mean total duration time of the procedures was 74.6 +/- 25.0 minutes. Postinterventional self-limiting fever occurred after 4 procedures in 3 patients with cholangitis. After therapeutic interventions all patients had a significant drop of bilirubin levels and all except one patient were free of complaints (follow-up 10.4 +/- 8.6 months). The DBE system permits diagnostic and therapeutic ERC in surgically modified anatomy, previously unavailable for endoluminal access. In our experience this procedure is safe and has a high success rate with a favourable patient outcome.

  19. Ileal polypoid lymphangiectasia bleeding diagnosed and treated by double balloon enteroscopy.

    PubMed

    Park, Min Seon; Lee, Beom Jae; Gu, Dae Hoe; Pyo, Jeung-Hui; Kim, Kyeong Jin; Lee, Yun Ho; Joo, Moon Kyung; Park, Jong-Jae; Kim, Jae Seon; Bak, Young-Tae

    2013-12-07

    Intestinal lymphangiectasia is a rare disease characterized by focal or diffuse dilated enteric lymphatics with impaired lymph drainage. It causes protein-losing enteropathy and may lead to gastrointestinal bleeding. Commonly, lymphangiectasia presents as whitish spots or specks. To our knowledge, small bowel bleeding resulting from polypoid intestinal lymphangiectasia has not been reported. Here, we report a rare case of active bleeding from the small bowel caused by polypoid lymphangiectasia with a review of the relevant literature. An 80-year-old woman was hospitalized for melena. Esophagogastroduodenoscopy could not identify the source of bleeding. Subsequent colonoscopy showed fresh bloody material gushing from the small bowel. An abdominal-pelvic contrast-enhanced computed tomography scan did not reveal any abnormal findings. Video capsule endoscopy showed evidence of active and recent bleeding in the ileum. To localize the bleeding site, we performed double balloon enteroscopy by the anal approach. A small, bleeding, polypoid lesion was found in the distal ileum and was successfully removed using endoscopic snare electrocautery. © 2013 Baishideng Publishing Group Co., Limited. All rights reserved.

  20. Esophageal stenosis in epidermolysis bullosum: a challenge for the endoscopist.

    PubMed

    De Angelis, Paola; Caldaro, Tamara; Torroni, Filippo; Romeo, Erminia; Foschia, Francesca; di Abriola, Giovanni Federici; Rea, Francesca; El Hachem, May; Genovese, Elisabetta; D'Alessandro, Sandra; Dall'Oglio, Luigi

    2011-05-01

    Esophageal stenosis is a severe complication in dystrophic epidermolysis bullosa (EB). Endoscopic dilations may cause mucosal injury with stricture recurrence. Our aim was to describe our referral EB-center experience on safety and long-term efficacy of fluoroscopically guided balloon dilation without endoscopy. Over 14 years, 34 patients with EB, previously evaluated with barium esophagogram for dysphagia, underwent balloon esophageal dilation. Under fluoroscopy, a guide wire was introduced via a nostril into the stomach. A 12-mm pneumatic balloon, which passed over the wire, was filled using radio-opaque contrast, dilating the stricture. Orotracheal intubation was avoided. Antibiotics, dexamethasone, and proton-pump inhibitors were administered. Study approval was obtained from our ethical board. Ninety-three dilations were performed. Seventeen patients had a single stenosis. The mean age of onset was 18 years (range, 3-47 years). Thirteen patients underwent one dilation. In 6 cases, endoscopy was necessary to visualize the esophageal lumen. Complications included cervical esophageal perforation (2) and transitory dysphagia (10). Thirty patients were feeding within 24 hours. During the follow-up, 2 patients required a gastrostomy, and 2 patients underwent fundoplication for gastroesophageal reflux disease. Fluoroscopically guided balloon dilation in EB is a safe and well-tolerated procedure. An experienced endoscopy team is necessary in certain cases. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Is there still a role for intraoperative enteroscopy in patients with obscure gastrointestinal bleeding?

    PubMed

    Monsanto, Pedro; Almeida, Nuno; Lérias, Clotilde; Figueiredo, Pedro; Gouveia, Hermano; Sofia, Carlos

    2012-04-01

    in 21st century, endoscopic study of the small intestine has undergone a revolution with capsule endoscopy and balloon-assisted enteroscopy. The difficulties and morbidity associated with intraoperative enteroscopy, the gold-standard in the 20th century, made this technique to be relegated to a second level. evaluate the actual role and assess the diagnostic and therapeutic value of intraoperative enteroscopy in patients with obscure gastrointestinal bleeding. we conducted a retrospective study of 19 patients (11 males; mean age: 66.5 ± 15.3 years) submitted to 21 IOE procedures for obscure GI bleeding. Capsule endoscopy and double balloon enteroscopy had been performed in 10 and 5 patients, respectively. with intraoperative enteroscopy a small bowel bleeding lesion was identified in 79% of patients and a gastrointestinal bleeding lesion in 94%. Small bowel findings included: angiodysplasia (n = 6), ulcers (n = 4), small bowel Dieulafoy´s lesion (n = 2), bleeding from anastomotic vessels (n = 1), multiple cavernous hemangiomas (n = 1) and bleeding ectopic jejunal varices (n = 1). Agreement between capsule endoscopy and intraoperative enteroscopy was 70%. Endoscopic and/or surgical treatment was used in 77.8% of the patients with a positive finding on intraoperative enteroscopy, with a rebleeding rate of 21.4% in a mean 21-month follow-up period. Procedure-related mortality and postoperative complications have been 5 and 21%, respectively. intraoperative enteroscopy remains a valuable tool in selected patients with obscure GI bleeding, achieving a high diagnostic yield and allowing an endoscopic and/or surgical treatment in most of them. However, as an invasive procedure with relevant mortality and morbidity, a precise indication for its use is indispensable.

  2. [A clinical observation of percutaneous balloon dilation and maintenance percutaneous transhepatic cholangial catheter drainage for treatment of 21 patients with benign biliary strictures and difficult endoscopy].

    PubMed

    Pan, Jie; Shi, Hai-feng; Li, Xiao-guang; Zhang, Xiao-bo; Liu, Wei; Jin, Zheng-yu; Hong, Tao; Yang, Ai-ming; Yang, Ning

    2012-06-01

    To investigate the value of percutaneous balloon dilation and percutaneous transhepatic cholangial drainage (PTCD) catheter maintenance in the treatment of benign biliary strictures. The clinical data of 21 patients with benign biliary strictures at Peking Union Medical College Hospital from June 2005 to June 2011 were retrospectively studied, in which 12 patients in severe stricture (stenosis > 70%) were treated with percutaneous balloon dilation and PTCD catheter placed across the stricture, while another 9 patients in median stricture (stenosis < 70%) were only treated with PTCD catheter maintenance. Of the 12 patients underwent balloon dilation and 6 - 12 months (median: 9 months) of PTCD catheter placement, 11 patients had the catheter successfully removed. In the follow-up of 6 - 24 months (median: 10 months), patency of bile duct was preserved in 9 of 11 patients, and recurrent stenosis was seen in 2 patients. A severe complication with biliary artery branch rupture and massive hemobilia was seen in 1 patient during balloon dilation. Of the 9 patients only treated with 1 - 12 months (median: 6 months) of PTCD catheter placement, 7 patients had the catheter successfully removed. In the follow-up of 5 - 18 months (median: 8 months), patency of bile duct was preserved in 5 of 7 patients, and recurrent stenosis was seen in 2 patients. No severe complication occurred. When endoscopy therapy is failed or the patient can't undergo endoscopy therapy, the percutaneous balloon dilation and PTCD catheter maintenance method is an effective alternative therapeutic approach in the treatment of benign biliary strictures. The moderate benign biliary stricture may be effectively treated only by the PTCD catheter maintenance method.

  3. Balloon enteroscopy versus spiral enteroscopy for small-bowel disorders: a systematic review and meta-analysis.

    PubMed

    Baniya, Ramkaji; Upadhaya, Sunil; Subedi, Subash Chandra; Khan, Jahangir; Sharma, Prabin; Mohammed, Tabrez Shaik; Bachuwa, Ghassan; Jamil, Laith H

    2017-12-01

    Two novel enteroscopic procedures, balloon enteroscopy and spiral enteroscopy, have revolutionized the diagnostic and therapeutic approach to small-bowel disorders. These disorders that historically required surgical interventions are now investigated and managed nonsurgically. Only a few weakly powered studies have compared the outcomes of spiral enteroscopy and balloon enteroscopy. We conducted a systematic review and meta-analysis to compare the efficacy and safety of these 2 procedures. PubMed, Cochrane Library, Scopus, and clinicaltrials.gov databases were searched for all studies published up to January 12, 2017 comparing the efficacy and safety of balloon enteroscopy (single or double) and spiral enteroscopy. Primary outcomes of interest were diagnostic and therapeutic success rates. Other outcomes included procedure length, depth of maximal insertion (DMI), rate of complete enteroscopy, and adverse events. We calculated Odds ratios (ORs) for categorical variables and mean difference (MD) for continuous variables. The Mantel-Haenszel method was used to analyze the data. Fixed and random effect models were used for <50% heterogeneity and >50% heterogeneity, respectively. Eight studies met the inclusion criteria for this meta-analysis. A total of 615 procedures were analyzed, which included 394 balloon enteroscopy and 221 spiral enteroscopy procedures. There were no significant differences in diagnostic and therapeutic success rates (OR, 1.27; 95% confidence interval [CI], .86-1.88; P = .22; and OR, 1.23; 95% CI, .82-1.84; P = .32, respectively) between the 2 procedures. Similarly, DMI was not significantly different between the 2 groups (MD, 26.29; 95% CI, 20.92-73.49; P = .28). However, the procedure time was significantly shorter for the spiral enteroscopy group compared with the balloon enteroscopy group (MD, 11.26; 95% CI, 2.72-19.79; P = .010). A subgroup analysis comparing double balloon enteroscopy with spiral enteroscopy yielded similar results. Both procedures achieved similar diagnostic and therapeutic outcomes and with similar depth of insertion. Spiral enteroscopy has the benefit of shorter procedural time. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. Photodynamic therapy for Barrett's esophagus using a 20-mm diameter light-delivery balloon

    NASA Astrophysics Data System (ADS)

    Panjehpour, Masoud; Overholt, Bergein F.; Phan, Mary N.; Haydek, John M.; Robinson, Amy R.

    2002-06-01

    Background and Objective: Patients with high grade dysplasia (HGD) in Barrett's esophagus are at a high risk for developing esophageal adenocarcinoma. Esophagectomy is the standard treatment for such patients. The objective of this study was to evaluate the safety and efficacy of photodynamic therapy (PDT) using an improved light delivery balloon for ablation of Barrett's esophagus with high grade dysplasia and/or early cancer. Materials and Methods: 20 patients with HGD or early cancer (19 with HGD, 1 with T1 cancer) received 2 mg/kg of porfimer sodium, intravenously. Two to three days after the injection, laser light was delivered using a cylindrical diffuser inserted inside a 20-mm diameter reflective esophageal PDT balloon. Initially, the balloon was inflated to a pressure of 80 mm Hg. The balloon pressure was gradually reduced to 30 mm Hg. A KTP/dye laser at 630 nm was used as the light source. Light dose of 115 J/cm was delivered at an intensity of 270 mw/cm. Nodules were pre- treated with an extra 50 J/cm using a short diffuser inserted through the scope. Patients were maintained on PPI therapy to keep the gastric pH higher than 4. Eighteen patients required one treatment, while two patients were treated twice. Follow-up consisted of endoscopy with four quadrant biopsies at every 2 cm of the treated area. Thermal ablation was used to treat small residual islands on the follow-ups. The follow-up endoscopies ranged from 6 to 17 months. Results: On follow-up endoscopy, 12 patients had complete replacement of their Barrett's mucosa with neosquamous mucosa. Five patients had residual non-dysplastic Barrett's mucosa, one had indefinite dysplasia, two had low grad dysplasia. There were no residual HGD or cancers. The average length of Barrett's was reduced from 5.4 cm to 1.2 cm. High balloon pressure resulted in wide variation in PDT response among patients. Lower balloon pressures resulted in more consistent destruction of Barrett's mucosa among patients. Five patients developed strictures which responded well to dilations. One patient developed atrial fibrillation which responded to medications. Conclusions: Photodynamic therapy using a 20 mm diameter balloon was effective for ablation of high grade dysplasia and early cancer in Barrett's esophagus. Low balloon inflation pressure was a critical parameter in producing consistent tissue destruction.

  5. A prospective comparison of performance during back-to-back, anterograde manual spiral enteroscopy and double-balloon enteroscopy.

    PubMed

    Despott, Edward J; Murino, Alberto; Bourikas, Leonidas; Nakamura, Masanao; Ramachandra, Vino; Fraser, Chris

    2015-05-01

    Spiral enteroscopy is a recently introduced technology alternative to balloon-assisted enteroscopy for examination of the small bowel. To compare small bowel insertion depths and procedure duration by spiral enteroscopy and double-balloon enteroscopy performed in the same cohort of patients, in immediate succession, using the same method of insertion depth estimation. A prospective, back-to-back comparative study was performed in 15 patients. Spiral enteroscopy procedures were performed first and a tattoo was placed to mark the most distal point. Double-balloon enteroscopy passed the tattoo placed at spiral enteroscopy in 14/15 cases (93%). Median insertion depths for double-balloon enteroscopy and spiral enteroscopy were 265cm and 175cm, respectively (P=0.004). Median time to achieve maximal depth of insertion was significantly shorter for spiral enteroscopy compared with double-balloon enteroscopy (24min vs. 45min, respectively; P=0.0005). However, in 14 patients no differences were found in median time to reach the same insertion depth (P=0.28). Double-balloon enteroscopy achieved significantly greater small bowel insertion depth than spiral enteroscopy. Although overall double-balloon enteroscopy procedure duration was longer, the time taken to reach the same small bowel insertion depth by both spiral enteroscopy and double-balloon enteroscopy was similar. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  6. Enteroscopy in the diagnosis and management of celiac disease.

    PubMed

    Rondonotti, Emanuele; Villa, Federica; Saladino, Valeria; de Franchis, Roberto

    2009-07-01

    Esophagogastroduodenoscopy (EGD) with 3 to 6 biopsies in the descending duodenum is the gold standard for the diagnosis of celiac disease. At the time of the first diagnosis of celiac disease, an extensive evaluation of the small bowel is not recommended. However, video capsule endoscopy, because of its good sensitivity and specificity in recognizing the Endoscopic features of celiac disease, can be considered a valid alternative to EGD in patients unable or unwilling to undergo EGD with biopsies. Capsule endoscopy is also a possible option in selected cases with strong suspicion of celiac disease but negative first-line tests. In evaluating patients with refractory or complicated celiac disease, in whom a complete evaluation of the small bowel is mandatory (at least in refractory celiac disease type II patients) because of the possible presence of complications beyond the reach of conventional endoscopes, both capsule endoscopy and balloon-assisted enteroscopy have been found to be helpful. In these patients, capsule endoscopy offers several advantages: it is well tolerated, it allows inspection of the entire small bowel, and it is able to recognize subtle mucosal changes. However, in this setting, capsule endoscopy should ideally be coupled with imaging techniques that provide important information about the thickness of the wall of the intestine and about extraluminal abnormalities. Although deep enteroscopy (such as balloon enteroscopy) is expensive, time-consuming, and potentially risky in these frail patients, they may have a key role, because they make it possible to take tissue samples from deep in the small intestine.

  7. Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues.

    PubMed

    Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y

    2016-02-01

    The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.

  8. Double balloon protection during carotid artery stenting for vulnerable carotid stenosis reduces the incidence of new brain lesions.

    PubMed

    Nakazaki, Masahito; Nonaka, Tadashi; Takahashi, Akira; Yonemasu, Yasuyuki; Nomura, Tatsufumi; Onda, Toshiyuki; Honda, Osamu; Hashimoto, Yuji; Ohnishi, Hirofumi; Sasaki, Masanori; Daibo, Masahiko; Honmou, Osamu

    2016-07-01

    The use of distal filter protection alone is associated with a high risk of ischemic complications when vulnerable carotid stenosis is treated by carotid artery stenting (CAS). Double balloon protection, a combination of distal balloon protection and proximal balloon occlusion, can be utilized. We assessed the outcome and complications of the double balloon protection method for vulnerable carotid stenosis. Among 130 patients who underwent CAS from 2009 to 2014, we enrolled the following patients: those whose target lesion was vulnerable as evaluated by MRI, i.e., a signal ratio of plaque to posterior cervical muscle on T1-weighted images before CAS of ≥1.5, and those who underwent diffusion-weighted imaging (DWI) studies within 48 h after the procedure. Ninety patients were enrolled. We investigated DWI findings of the double balloon protection group compared with those of the simple distal balloon protection and distal filter protection groups. Sixty-four patients (71 %) underwent double balloon protection, 15 patients (17 %) simple distal balloon protection, and 11 patients (12 %) distal filter protection. Symptomatic embolic complications and new lesions on DWI after CAS were significantly less common in patients undergoing double balloon protection compared to distal balloon protection or distal filter protection (0 % vs. 20 %, 9 %, P < 0.01, and 30 % vs. 67 %, 82 %, P < 0.01, respectively). Logistic regression analysis also identified the odds ratio of double balloon protection for new lesions on DWI after CAS of 0.23 (95 % confidence interval: 0.07-0.70, P < 0.01) compared to simple distal protections. In the patients who underwent CAS for vulnerable carotid stenosis, double balloon protection was an independent significant factor associated with a reduction in the risk of new lesions on DWI after the procedure compared to conventional distal protections.

  9. Enteroscopy

    MedlinePlus

    Small bowel biopsy; Push enteroscopy; Double-balloon enteroscopy; Capsule enteroscopy ... into the upper gastrointestinal tract. During a double-balloon enteroscopy, balloons attached to the endoscope can be ...

  10. Current status of device-assisted enteroscopy: Technical matters, indication, limits and complications

    PubMed Central

    Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Bizzotto, Alessandra; Galasso, Domenico; Costamagna, Guido

    2012-01-01

    Enteroscopy, defined as direct visualization of the small bowel with the use of a fiberoptic or capsule endoscopy, has progressed considerably over the past several years. The need for endoscopic access to improve diagnosis and treatment of small bowel disease has led to the development of novel technologies one of which is non-invasive, the video capsule, and a type of invasive technique, the device-assisted enteroscopy. In particular, the device-assisted enteroscopy consists then of three different types of instruments all able to allow, in skilled hands, to display partially or throughout its extension (if necessary) the small intestine. Newer devices, double balloon, single balloon and spiral endoscopy, are just entering clinical use. The aim of this article is to review recent advances in small bowel enteroscopy, focusing on indications, modifications to improve imaging and techniques, pitfalls, and clinical applications of the new instruments. With new technologies, the trials and tribulations of learning new endoscopic skills and determining their role in the diagnosis and treatment of small bowel disease come. Identification of small bowel lesions has dramatically improved. Studies are underway to determine the best strategy to apply new enteroscopy technologies for the diagnosis and management of small bowel disease, particularly obscure bleeding. Vascular malformations such as angiectasis and small bowel neoplasms as adenocarcinoma or gastrointestinal stromal tumors. Complete enteroscopy of the small bowel is now possible. However, because of the length of the small bowel, endoscopic examination and therapeutic maneuvers require significant skill, radiological assistance, the use of deep sedation with the assistance of the anesthetist. Prospective randomized studies are needed to guide diagnostic testing and therapy with these new endoscopic techniques. PMID:23189216

  11. Role of endoscopy in inflammatory bowel disease

    PubMed Central

    Bharadwaj, Shishira; Narula, Neeraj; Tandon, Parul; Yaghoobi, Mohammad

    2018-01-01

    Abstract Crohn’s disease (CD) and ulcerative colitis (UC) constitute the two most common phenotypes of inflammatory bowel disease (IBD). Ileocolonoscopy with biopsy has been considered the gold standard for the diagnosis of IBD. Differential diagnosis of CD and UC is important, as their medical and surgical treatment modalities and prognoses can be different. However, approximately 15% of patients with IBD are misdiagnosed as IBD unclassified due to the lack of diagnostic certainty of CD or UC. Recently, there has been increased recognition of the role of the therapeutic endoscopist in the field of IBD. Newer imaging techniques have been developed to aid in the differentiation of UC vs CD. Furthermore, endoscopic balloon dilation and stenting have become an integral part of the therapeutic armamentarium of CD stricture management. Endoscopic ultrasound has been recognized as being more accurate than magnetic resonance imaging in detecting perianal fistulae in patients with CD. Additionally, chromoendoscopy may help to detect dysplasia earlier compared with white-light colonoscopy. Hence, interventional endoscopy has become a cornerstone in the diagnosis, treatment and management of IBD complications. The role of endoscopy in the field of IBD has significantly evolved in recent years from small-bowel imaging to endoscopic balloon dilation and use of chormoendoscopy in dysplasia surveillance. In this review article, we discuss the current evidence on interventional endoscopy in the diagnosis, treatment and management of IBD compications. PMID:29780594

  12. Clinical outcomes of enteroscopy using the double-balloon method for strictures of the small intestine

    PubMed Central

    Sunada, Keijiro; Yamamoto, Hironori; Kita, Hiroto; Yano, Tomonori; Sato, Hiroyuki; Hayashi, Yoshikazu; Miyata, Tomohiko; Sekine, Yutaka; Kuno, Akiko; Iwamoto, Michiko; Ohnishi, Hirohide; Ido, Kenichi; Sugano, Kentaro

    2005-01-01

    AIM: To evaluate the clinical outcome of enteroscopy, using the double-balloon method, focusing on the involvement of neoplasms in strictures of the small intestine. METHODS: Enteroscopy, using the double-balloon method, was performed between December 1999 and December 2002 at Jichi Medical School Hospital, Japan and strictures of the small intestine were found in 17 out of 62 patients. These 17 consecutive patients were subjected to analysis. RESULTS: The double-balloon enteroscopy contributed to the diagnosis of small intestinal neoplasms found in 3 out of 17 patients by direct observation of the strictures as well as biopsy sampling. Surgical procedures were chosen for these three patients, while balloon dilation was chosen for the strictures in four patients diagnosed with inflammation without involvement of neoplasm. CONCLUSION: Double-balloon enteroscopy is a useful method for the diagnosis and treatment of strictures in the small bowel. PMID:15742422

  13. Direct retrograde cholangioscopy with a new prototype double-bending cholangioscope.

    PubMed

    Beyna, Torsten; Farnik, Harald; Sarrazin, Christoph; Gerges, Christian; Neuhaus, Horst; Albert, Jörg G

    2016-10-01

    Direct retrograde cholangioscopy (DRC) enables high quality video imaging of the bile ducts and allows intraductal treatment with optical control. We evaluated the feasibility, success, and complications of a new third-generation prototype cholangioscope. All consecutive patients from two tertiary endoscopy centers who had undergone DRC with the prototype were included. Indications for DRC were: evaluation of indeterminate strictures, filling defects, and complex bile duct stones. Technical success was investigated in terms of indication and treatment performed. All adverse events were recorded. DRC with the prototype was performed in 74 patients. Therapeutic interventions included laser or electrohydraulic lithotripsy and stone removal, among others. The papilla was entered in 72/74 patients (97 %). The targeted bile duct segment was reached in 62 /74 patients (84 %), with an anchoring balloon catheter needed in 21/74 (28 %). Mean investigation time was 21 minutes (15 - 27 minutes) DRC using the prototype is feasible, safe, and attains access to the bile ducts in almost all patients, with less need of an anchoring balloon catheter compared with the standard technique and short investigation and fluoroscopy times. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Single balloon versus double balloon bipedicular kyphoplasty: a systematic review and meta-analysis.

    PubMed

    Jing, Zehao; Dong, Jianli; Li, Zhengwei; Nan, Feng

    2018-06-19

    Kyphoplasty has been widely used to treat vertebral compression fractures (VCFs). In standard procedure of kyphoplasty, two balloons were inserted into the vertebral body through bipedicular and inflated simultaneously, while using a single balloon two times is also a common method in clinic to lessen the financial burden of patients. However, the effect and safety of single balloon versus double balloon bipedicular kyphoplasty are still controversy. In this systematic review and meta-analysis, eligible studies were identified through a comprehensive literature search of PubMed, Cochrane library EMBASE, Web of Science, Wanfang, CNKI, VIP and CBM until January 1, 2018. Results from individual studies were pooled using a random or fixed effects model. Seven articles were included in the systematic review and five studies were consisted in meta-analysis. We observed no significant difference between single balloon and double balloon bipedicular kyphoplasty in visual analog scale (VAS), angle (kyphotic angle and Cobb angle), consumption (operation time, cement volume and volume of bleeding), vertebral height (anterior height, medium height and posterior height) and complications (cement leakage and new VCFs), while the cost of single balloon bipedicular kyphoplasty is lower than that of double balloon bipedicular kyphoplasty. The results of our meta-analysis also demonstrated that single balloon can significantly improve the VAS, angle and vertebral height of patients suffering from VCFs. This systematic review and meta-analysis collectively concludes that single balloon bipedicular kyphoplasty is as effective as double balloon bipedicular kyphoplasty in improving clinical symptoms, deformity and complications of VCFs but not so expensive. These slides can be retrieved under Electronic Supplementary Material.

  15. Double balloon catheter for induction of labour in Chinese women with previous caesarean section: one-year experience and literature review.

    PubMed

    Cheuk, Queenie K Y; Lo, T K; Lee, C P; Yeung, Anita P C

    2015-06-01

    To evaluate the efficacy and safety of double balloon catheter for induction of labour in Chinese women with one previous caesarean section and unfavourable cervix at term. Retrospective cohort study. A regional hospital in Hong Kong. Women with previous caesarean delivery requiring induction of labour at term and with an unfavourable cervix from May 2013 to April 2014. Primary outcome was to assess rate of successful vaginal delivery (spontaneous or instrument-assisted) using double balloon catheter. Secondary outcomes were double balloon catheter induction-to-delivery and removal-to-delivery interval; cervical score improvement; oxytocin augmentation; maternal or fetal complications during cervical ripening, intrapartum and postpartum period; and risk factors associated with unsuccessful induction. All 24 Chinese women tolerated double balloon catheter well. After double balloon catheter expulsion or removal, the cervix successfully ripened in 18 (75%) cases. The improvement in Bishop score 3 (interquartile range, 2-4) was statistically significant (P<0.001). Overall, 18 (75%) cases were delivered vaginally. The median insertion-to-delivery and removal-to-delivery intervals were 19 (interquartile range, 13.4-23.0) hours and 6.9 (interquartile range, 4.1-10.8) hours, respectively. Compared with cases without, the interval to delivery was statistically significantly shorter in those with spontaneous balloon expulsion or spontaneous membrane rupture during ripening (7.8 vs 3.0 hours; P=0.025). There were no major maternal or neonatal complications. The only factor significantly associated with failed vaginal birth after caesarean was previous caesarean section for failure to progress (P<0.001). This is the first study using double balloon catheter for induction of labour in Asian Chinese women with previous caesarean section. Using double balloon catheter, we achieved a vaginal birth after caesarean rate of 75% without major complications.

  16. Embolization of direct carotid cavernous fistulas with the novel double-balloon technique

    PubMed Central

    Niu, Yin; Li, Lin; Tang, Jun; Zhu, Gang

    2015-01-01

    Multiple endovascular management of direct carotid cavernous fistula (CCF) has been widely accepted as a treatment option. Embolization of the fistula with detachable balloons or thrombogenic coil-based occlusion has been the main choice to treat direct CCF, with good safety and efficacy. This study investigated the safety and efficacy of embolization of direct CCF with the novel double-balloon technique. A retrospective review of a prospective database on cerebral vascular disease was performed. We identified a total of five patients presenting with high-flow direct CCF. All patients were managed with transarterial embolization with the novel double-balloon technique. Three of the five patients were treated with two detachable balloons, and a completely occluded fistula with preservation of the internal carotid artery was achieved. Of the remaining two patients treated with more detachable balloons, one patient achieved a perfect outcome and the other one suffered from recurrent fistula due to balloon migration 3 weeks after embolization. During a follow-up period of 12–18 months, no symptoms reoccurred in any patient. Thus, the double-balloon treatment may be a promising method for CCF complete occlusion. This novel technique may bring more benefits in the following two cases: 1). A single inflated detachable balloon fails to completely occlude the CCF, which causing the next balloon can not pass into the fistula. 2). A giant CCF needs more balloons for fistula embolization. PMID:26586136

  17. [Efficacy of double balloon enteroscopy for patients with intestinal lymphangiectasia, case report of primary intestinal lymphangiectasia].

    PubMed

    Yakami, Yoshikazu; Watanabe, Kenji; Kameda, Natsuhiko; Machida, Hirohisa; Okazaki, Hirotoshi; Yamagami, Hirokazu; Shiba, Masatsugu; Fujiwara, Yasuhiro; Oshitani, Nobuhide; Arakawa, Tetsuo

    2008-11-01

    A 31-year-old man has visited our hospital, complaining diarrhea and leg edema. Blood test showed hypoalbuminea, but we couldn't find the reason by several examinations. Therefore, we performed double balloon enteroscopy, and intestinal lymphangiectasia was diagnosed histologically by biopsy. It's useful and effective to perform double balloon enteroscopy and histological examination for the unknown origin case of protein loosing enteropathy.

  18. Detection Rate and Clinical Relevance of Ink Tattooing during Balloon-Assisted Enteroscopy

    PubMed Central

    Ebigbo, A.; Schrempf, M.; Messmann, H.; Gölder, S. K.

    2017-01-01

    Background and Aims Balloon-assisted enteroscopy (BAE) is a well-established tool in the diagnosis and therapy of small bowel diseases. Ink tattooing of the small bowel is used to mark pathologic lesions or the depth of small bowel insertion. The purpose of this study was to determine the safety, the detection rate, and the clinical relevance of ink tattooing during BAE. Methods We performed a retrospective analysis of all 81 patients who received an ink tattooing during BAE between 2010 and 2015. Results In all patients, ink tattooing was performed with no complications. 26 patients received a capsule endoscopy after BAE. The tattoo could be detected via capsule endoscopy in 19 of these 26 patients. The tattoo of the previous BAE could be detected via opposite BAE in 2 of 11 patients. In 9 patients, ink tattooing influenced the choice of approach for reenteroscopy. In 7 patients, the tattoo was used for intraoperative localization and in 3 patients for intraoperative localization as well as for reenteroscopy. The intraoperative detection rate of the tattoo was 100%. Conclusion Ink tattooing of the small intestine is a safe endoscopic procedure to mark the depth of scope insertion or a pathologic lesion during balloon-assisted enteroscopy. PMID:29230241

  19. Controlled weather balloon ascents and descents for atmospheric research and climate monitoring

    PubMed Central

    Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.

    2017-01-01

    In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth’s surface to about 35 km (3–5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent. PMID:29263765

  20. Controlled weather balloon ascents and descents for atmospheric research and climate monitoring.

    PubMed

    Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F; Hall, Emrys G; Jordan, Allen F

    2016-01-01

    In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.

  1. Clinical usefulness of a short-type, prototype single-balloon enteroscope for endoscopic retrograde cholangiopancreatography in patients with altered gastrointestinal anatomy: preliminary experiences.

    PubMed

    Kawamura, Takuji; Uno, Koji; Suzuki, Azumi; Mandai, Koichiro; Nakase, Kojiro; Tanaka, Kiyohito; Yasuda, Kenjiro

    2015-01-01

    A limited number of endoscopic retrograde cholangiopancreatography (ERCP) accessories are compatible with the conventional single-balloon enteroscope (SBE) because of the latter's dimensions. The aim of the present study was to assess the utility of a prototype SBE that has a shorter working length and a wider channel than the conventional SBE. ERCP procedures carried out between January 2012 and July 2013 using the short SBE prototype were reconstructions such as Billroth II (B-II), post-gastrectomy with Roux-en-Y (RY-G), and post-choledochojejunostomy with Roux-en-Y (RY-CJ). We retrospectively analyzed the rate of reaching the blind end of the intestine, the diagnostic success rate, the interventional success rate, and the frequency of related complications. Twenty-seven ERCP procedures on 18 patients analyzed comprised two B-II, 15 RY-G, and 10 RY-CJ reconstructions. With a mean procedure time of 56 min (range 40-150 min), the rate of reaching the blind end, the diagnostic success rate, and the interventional success rate were 24/27 (89%), 20/27 (74%), and 19/27 (70%), respectively. There were no major ERCP-related complications in any patient. The prototype short-type SBE appears safe and effective for use in ERCP, and is compatible with conventional endoscopy accessories. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  2. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation.

    PubMed

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2013-05-31

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.

  3. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation.

    PubMed

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2014-05-01

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery.

  4. Occlusion of M1 segment after superficial temporal artery-middle cerebral artery bypass in a giant M1 aneurysm with Onyx-34 injected via a double-lumen balloon under balloon inflation

    PubMed Central

    Clarençon, Frédéric; Nouet, Aurelien; Redondo, Aimée; Di Maria, Federico; Iosif, Christina; Le Jean, Lise; Chiras, Jacques; Sourour, Nader

    2013-01-01

    A 29-year-old patient attended our institution for recurrent strokes related to a giant partially thrombosed M1 aneurysm. Superficial temporal artery-middle cerebral artery (STA-MCA) bypass and subsequent occlusion of both the aneurysm and the dysplastic M1 segment were planned. However, owing to the shortness of the non-dysplastic segment of M1 and the risk of occlusion of the lenticulostriate arteries, the use of a double-lumen balloon was considered for coiling and subsequent injection of Onyx. STA-MCA bypass was performed using a regular technique. Endovascular occlusion of both the aneurysm and the parent artery was subsequently performed by means of coils and Onyx-34 that was injected via the Ascent balloon under balloon inflation. No complications were recorded and no stroke was observed on control MRI. The injection of Onyx-34 through a double-lumen balloon under balloon inflation is a quick and safe technique for precise occlusion of a parent artery. PMID:23729720

  5. New therapeutic perspectives in non-alcoholic steatohepatitis.

    PubMed

    Ampuero, Javier; Sánchez-Torrijos, Yolanda; Aguilera, Virginia; Bellido, Francisco; Romero-Gómez, Manuel

    2018-02-01

    Management of non-alcoholic steatohepatitis is focused on restitution of metabolic derangement, weight loss and drugs able to improve steatosis, ballooning and fibrosis. Life-style interventions based on Mediterranean diet and increasing physical activity are the first line therapy. In patients with unsuccessful life-style intervention several drugs are under development: agonist PPAR, agonist GLP-1R and agonist FXR together with drugs focussing on inflammation, ballooning, apoptosis and fibrosis. Bariatric surgery or advanced endoscopy are reserved for morbid obese without response to life-style intervention and weighting loss drugs. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  6. [Usefulness of systematic chromoendoscopy with a double dye staining technique for the detection of dysplasia in patients with premalignant gastric lesions].

    PubMed

    Yep-Gamarra, Víctor; Díaz-Vélez, Cristian; Araujo, Isis; Ginès, Àngels; Fernández-Esparrach, Gloria

    2016-02-01

    Premalignant gastric lesions have an increased risk to develop gastric cancer. To evaluate the usefulness of systematic endoscopy that includes chromoendoscopy with a double dye staining technique for the detection of dysplasia in patients with premalignant gastric lesions. This longitudinal, prospective study was performed in patients with gastric atrophy, intestinal metaplasia or dysplasia who were referred for endoscopy less than 6 months after the initial diagnosis. The second endoscopy was performed in three phases: phase 1, exhaustive and systematic review of the mucosa with photographic documentation and biopsies of suspicious areas; phase 2, chromoendoscopy with a double dye staining technique using acetic acid 1.2% and indigo carmine 0.5%; phase 3, topographic mapping and random biopsies. A total of 50 patients were included. Nine (18%) had atrophic gastritis, 38 (76%) had intestinal metaplasia, and 3 (6%) had low-grade dysplasia. Systematic endoscopy with chromoendoscopy using a double dye staining technique detected more patients with dysplasia (9 versus 3, p<.05), and a larger number of biopsies with the diagnosis of dysplasia were obtained. This occurred for visible (6 vs. 0, p<.05) and non-visible lesions (6 vs. 3, p=NS). In one patient, initial low-grade dysplasia was not detected again in the systematic endoscopy, giving a global endoscopic performance for the detection of lesions of 92%. Patients with premalignant gastric lesions have synchronous lesions with greater histological severity, which are detected when systematic endoscopy is conducted with indigo carmine dye added to acetic acid. Copyright © 2015 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.

  7. Cerebral Arterial Gas Embolism During Upper Endoscopy.

    PubMed

    Eoh, Eun J; Derrick, Bruce; Moon, Richard

    2015-09-15

    Arterial gas embolism can be caused by direct entry of gas into systemic arteries or indirectly by venous-to-arterial shunting. Although arterial gas embolism is rare, most documented cases are iatrogenic, resulting from the entry of gas during procedures that involve direct vascular cannulation or intracavitary air insufflation. Of the 18 identified case reports of air embolism during endoscopy, 11 cases describe findings of cerebral arterial gas embolism during upper endoscopy. Only 1 of these occurred during endoscopic balloon dilation of an esophageal stricture. We report a rare case of cerebral arterial gas embolism in a 64-year-old woman, which occurred during endoscopic dilation of an esophageal stricture and was subsequently treated with hyperbaric oxygen therapy. In this case report, we explore the possible etiologies, clinical workup, and therapeutic management of cerebral artery gas embolisms. Hyperbaric oxygen therapy is the treatment of choice for cerebral arterial gas embolism, with earlier treatments resulting in better outcomes.

  8. Endoscopic Therapy in Crohn's Disease: Principle, Preparation, and Technique.

    PubMed

    Chen, Min; Shen, Bo

    2015-09-01

    Stricture and fistula are common complications of Crohn's disease. Endoscopic balloon dilation and needle-knife stricturotomy has become a valid treatment option for Crohn's disease-associated strictures. Endoscopic therapy is also increasingly used in Crohn's disease-associated fistula. Preprocedural preparations, including routine laboratory testing, imaging examination, anticoagulant management, bowel cleansing and proper sedation, are essential to ensure a successful and safe endoscopic therapy. Adverse events, such as perforation and excessive bleeding, may occur during endoscopic intervention. The endoscopist should be well trained, always be cautious, anticipate for possible procedure-associated complications, be prepared for damage control during endoscopy, and have surgical backup ready. In this review, we discuss the principle, preparation, techniques of endoscopic therapy, as well as the prevention and management of endoscopic procedure-associated complications. We propose that inflammatory bowel disease endoscopy may be a part of training for "super" gastroenterology fellows, i.e., those seeking a career in advanced endoscopy or in inflammatory bowel disease.

  9. Primary intestinal lymphangiectasia: Minireview

    PubMed Central

    Ingle, Sachin B; Hinge (Ingle), Chitra R

    2014-01-01

    Primary idiopathic intestinal lymphangiectasia is an unusual disease featured by the presence of dilated lymphatic channels which are located in the mucosa, submucosa or subserosa leading to protein loosing enteropathy.Most often affected were children and generally diagnosed before third year of life but may be rarely seen in adults too. Bilateral pitting oedema of lower limb is the main clinical manifestation mimicking the systemic disease and posing a real diagnostic dilemma to the clinicians to differentiate it from other common systemic diseases like Congestive cardiac failure, Nephrotic Syndrome, Protein Energy Malnutrition, etc. Diagnosis can be made on capsule endoscopy which can localise the lesion but unable to take biopsy samples. Thus, recently double-balloon enteroscopy and biopsy in combination can be used as an effective diagnostic tool to hit the correct diagnosis. Patients respond dramatically to diet constituting low long chain triglycerides and high protein content with supplements of medium chain triglyceride. So early diagnosis is important to prevent untoward complications related to disease or treatment for the sake of accurate pathological diagnosis. PMID:25325063

  10. Cutting balloon and high-pressure balloon dilation for palliative treatment of congenital double-chambered right ventricle and primary infundibular stenosis in a Golden retriever dog.

    PubMed

    Schober, Karsten E; Rhinehart, Jaylyn; Kohnken, Rebecca; Bonagura, John D

    2017-12-01

    Combined cutting balloon and high-pressure balloon dilation was performed in a dog with a double-chambered right ventricle and severe infundibular stenosis of the right ventricular outflow tract. The peak systolic pressure gradient across the stenosis decreased by 65% after dilation (from 187 mmHg before to 66 mmHg after) affirming the intervention as successful. However, early re-stenosis occurred within 3 months leading to exercise intolerance, exercise-induced syncope, and right-sided congestive heart failure. Cutting balloon followed by high-pressure balloon dilation provided temporary but not long-term relief of right ventricular obstruction in this dog. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    PubMed

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.

  12. Development of Bariatric and Metabolic Endoscopy

    PubMed Central

    Li, Shi-Han; Wang, Yong-Jun; Zhang, Shu-Tian

    2018-01-01

    Objective: With the evolution of society and changes in human lifestyle, obesity is becoming increasingly prevalent worldwide, and obesity-related comorbidities such as diabetes, hyperlipidemia, hypertension, and coronary heart disease are more common. As a result, new devices and methods for bariatric and metabolic endoscopy are being developed for clinical use, offering new options for patients. This review discussed the progress in bariatric and metabolic endoscopy. Data Sources: This review was based on data in articles published in the PubMed database up to September 2017, with the following keywords: “obesity”, “endoscopy”, “weight loss”, and “metabolism”. Study Selection: Original articles about various endoscopic methods of weight loss and other reviews of bariatric and metabolic endoscopy were included and analyzed. Results: The technology of bariatric and metabolic endoscopy has advanced rapidly in recent years. The intragastric balloon (IGB), with its comparatively long period of development, is the most mature and widely used instrument. Multiple new endoscopic devices have been created in recent years, with different targets to achieve weight loss. Despite the proliferation of new devices, the lack of clinical data results in a shortage of clinical experience and instruction in the use of this new equipment. Conclusions: Bariatric and metabolic endoscopy would help obese people lose weight or prepare for bariatric surgery and hopefully alleviate some of the complications of bariatric procedures. Adequate studies and data are still needed for the new endoscopic devices. PMID:29271386

  13. Double-Balloon-Assisted n-Butyl-2-Cyanoacrylate Embolization of Intrahepatic Arterioportal Shunt Prior to Chemoembolization of Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp; Shibata, Eisuke; Ohtomo, Kuni

    A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for othermore » than intrahepatic arterioportal shunt.« less

  14. [Characteristics of Crohn's disease under 
double balloon enteroscopy].

    PubMed

    Jia, Jia; Liu, Rui; Liu, Xiangjie; Shen, Shourong; Guo, Qin

    2018-05-28

    To observe ulcer characteristics of Crohn's disease under double balloon enteroscopy, and to evaluate the correlation between endoscopic severity and clinical manifestations.
 Methods: A prospective, observational study from July 2015 to December 2016 in the Third Xiangya Hospital, Central South University, we selected 45 patients with positive double-balloon enteroscopy (DBE) and confirmed Crohn's disease. Two digestive internal physician observed the ulcer characteristics of Crohn's disease under double balloon enteroscopy, and gave a simple endoscopic score for CD (SES-CD). We analyzed the correlation between SES-CD and Crohn's disease activity index (CDAI).
 Results: DBE indicated 24 patient ulcers (53.33%) locating at the end of the ileum, 5 (11.11%) locating at ileocolon, 16 (35.56%) locating at upper gatrointestinal tract and they did not affect the end of the ileum. Among them, 8 cases (17.78%) affected only jejunum. Thirty-two patients with longitudinal ulcers in Crohn's disease, accounting for 71.11%. There was no correlation between SES-CD score and CDAI score (r=0.237, P=0.136).
 Conclusion: The ulcerative appearance in Crohn's disease were diverse under double balloon enteroscopy. Crohn's disease could only affect the upper gastrointestinal tract or jejunum. The unwounded ileum and ileocecal valve couldn't be a sign to exclude Crohn's disease. CDAI score couldn't fully assess the prognosis of Crohn's disease.

  15. Utility of the Anterior Oblique-Viewing Endoscope and the Double-Balloon Enteroscope for Endoscopic Retrograde Cholangiopancreatography in Patients with Billroth II Gastrectomy

    PubMed Central

    Sen-yo, Manabu; Kaino, Seiji; Suenaga, Shigeyuki; Uekitani, Toshiyuki; Yoshida, Kanako; Harano, Megumi; Sakaida, Isao

    2012-01-01

    Background/Purpose. The difficulties of endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy have been reported. We evaluated the usefulness of an anterior oblique-viewing endoscope and a double-balloon enteroscope for endoscopic retrograde cholangiopancreatography in such patients. Methods. From January 2003 to December 2011, 65 patients with Billroth II gastrectomy were enrolled in this study. An anterior oblique-viewing endoscope was used for all patients. From February 2007, a double-balloon enteroscope was used for the failed cases. The success rate of procedures was compared with those in 20 patients with Billroth II gastrectomy using forward-viewing endoscope or side-viewing endoscope from March 1996 to July 2002 as historical controls. Results. In all patients in whom the papilla was reached (60/65), selective cannulation was achieved. The success rate of selective cannulation and accomplishment of planned procedures in the anterior oblique-viewing endoscope group were both significantly higher than that in the control group (100% versus 70.1%, 100 versus 58.8%, resp.). A double-balloon enteroscope was used in 2 patients, and the papilla could be reached and the planned procedures completed. Conclusions. An anterior oblique-viewing endoscope and double-balloon enteroscope appear to be useful in performing endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy. PMID:23056039

  16. Endoscopic features of gastro-intestinal lymphomas: From diagnosis to follow-up

    PubMed Central

    Vetro, Calogero; Romano, Alessandra; Amico, Irene; Conticello, Concetta; Motta, Giovanna; Figuera, Amalia; Chiarenza, Annalisa; Di Raimondo, Cosimo; Giulietti, Giorgio; Bonanno, Giacomo; Palumbo, Giuseppe Alberto; Di Raimondo, Francesco

    2014-01-01

    Many progresses have been done in the management of gastrointestinal (GI) lymphomas during last decades, especially after the discovery of Helicobacter pylori-dependent lymphoma development. The stepwise implementation of new endoscopic techniques, by means of echoendoscopy or double-balloon enteroscopy, enabled us to more precisely describe the endoscopic features of GI lymphomas with substantial contribution in patient management and in tailoring the treatment strategy with organ preserving approaches. In this review, we describe the recent progresses in GI lymphoma management from disease diagnosis to follow-up with a specific focus on the endoscopic presentation according to the involved site and the lymphoma subtype. Additionally, new or emerging endoscopic technologies that have an impact on the management of gastrointestinal lymphomas are reported. We here discuss the two most common subtypes of GI lymphomas: the mucosa-associated lymphoid tissue and the diffuse large B cell lymphoma. A general outline on the state-of-the-art of the disease and on the role of endoscopy in both diagnosis and follow-up will be performed. PMID:25278693

  17. Gastric antral webs in adults: A case series characterizing their clinical presentation and management in the modern endoscopic era

    PubMed Central

    Morales, Shannon J; Nigam, Neha; Chalhoub, Walid M; Abdelaziz, Dalia I; Lewis, James H; Benjamin, Stanley B

    2017-01-01

    AIM To investigate the current management of gastric antral webs (GAWs) among adults and identify optimal endoscopic and/or surgical management for these patients. METHODS We reviewed our endoscopy database seeking to identify patients in whom a GAW was visualized among 24640 esophagogastroduodenoscopies (EGD) over a seven-year period (2006-2013) at a single tertiary care center. The diagnosis of GAW was suspected during EGD if aperture size of the antrum did not vary with peristalsis or if a “double bulb” sign was present on upper gastrointestinal series. Confirmation of the diagnosis was made by demonstrating a normal pylorus distal to the GAW. RESULTS We identified 34 patients who met our inclusion criteria (incidence 0.14%). Of these, five patients presented with gastric outlet obstruction (GOO), four of whom underwent repeated sequential balloon dilations and/or needle-knife incisions with steroid injection for alleviation of GOO. The other 29 patients were incidentally found to have a non-obstructing GAW. Age at diagnosis ranged from 30-87 years. Non-obstructing GAWs are mostly incidental findings. The most frequently observed symptom prompting endoscopic work-up was refractory gastroesophageal reflux (n = 24, 70.6%) followed by abdominal pain (n = 11, 33.4%), nausea and vomiting (n = 9, 26.5%), dysphagia (n = 6, 17.6%), unexplained weight loss, (n = 4, 11.8%), early satiety (n = 4, 11.8%), and melena of unclear etiology (n = 3, 8.82%). Four of five GOO patients were treated with balloon dilation (n = 4), four-quadrant needle-knife incision (n = 3), and triamcinolone injection (n = 2). Three of these patients required repeat intervention. One patient had a significant complication of perforation after needle-knife incision. CONCLUSION Endoscopic intervention for GAW using balloon dilation or needle-knife incision is generally safe and effective in relieving symptoms, however repeat treatment may be needed and a risk of perforation exists with thermal therapies. PMID:28101304

  18. Carotid artery stenting with double cerebral embolic protection in asymptomatic patients - a diffusion-weighted MRI controlled study.

    PubMed

    Vuruskan, Ertan; Saracoglu, Erhan; Ergun, Ugur; Poyraz, Fatih; Duzen, İrfan Veysel

    2017-01-01

    The aim of this study was to compare the simultaneous double-protection method (proximal balloon plus distal filter) with distal-filter protection or proximal-balloon protection alone in asymptomatic patients during carotid artery stenting. 119 consecutive patients were investigated for carotid artery stentings in the extracranial internal carotid artery with the use of distal filters (n = 41, 34.4 %), proximal balloon (MoMa) protection (n = 40, 33.6 %) or double protection (n = 38, 31.9 %). Magnetic resonance imaging (MRI) was performed on all patients before the procedure, and control diffusion-weighted MRI (DW-MRI) was obtained within 24-48 h after the procedure. Procedural data, complications, success rate, major adverse cardiovascular events, and MRI findings were collected. New cerebral high-intensity (HI) lesions were observed in 47 (39.4 %) patients. HI lesions were observed in 22 (53.6 %), 15 (37.5 %), and 10 (26.3 %) of the patients with distal filters, proximal protection, and double protection, respectively (p = 0.004). The average number of HI lesions on DW-MRI was 1.80 in the distal-filter group, 0.90 in the proximal-balloon group, and 0.55 in the double-protection group (p < 0.001). Procedure and fluoroscopy times were slightly longer in the double-protection group compared to the distal- or proximal-protection groups (p = 0.001). The double (proximal plus distal) cerebral embolic protection technique is safe and effective for minimizing the risk of cerebral embolization, even in patients with asymptomatic carotid artery stenosis, despite slightly longer procedure and fluoroscopy times.
.

  19. Baby Shampoo versus Commercial Anti-fogging Solution to Prevent Fogging during Nasal Endoscopy: A Randomized Double-Blinded, Matched-Pair, Equivalent Trial.

    PubMed

    Chainansamit, Seksun; Piromchai, Patorn; Anantpinijwatna, Intira; Kasemsiri, Pornthep; Thanaviratananich, Sanguansak

    2015-08-01

    To compare the minimization of the fog condensation during nasal endoscopy between a commercial anti-fogging agent and baby shampoo. This randomized double-blinded matched pair study was conducted at the Department of Otorhinolaryngology, Faculty of Medicine, Khon Kaen University during February 4, 2013 to March 14, 2013. The commercial anti-fogging solution (Ultrastop®) and baby shampoo solution (Johnson's® no more tear®) were compared. A computer generated randomization was performed to select the solution applying on the lens for nasal endoscopy of the right nasal cavity. The other solution was then used for the left one. Three passes of endoscopy were performed to examine the floor of the nose, the sphenoethmoidal recess and the middle meatus area which spent about 30 seconds for each time of endoscopy. The time to become foggy on the lens and the preferred solution assessed by the endoscopists were recorded. There were 71 eligible patients recruited in the study, 37 males (52.1%) and 34 females (47.9%). There was no fogging during a 30-second nasal endoscopy either by baby shampoo or commercial anti-fogging solution. However, 9.86% (95% C12.75-16.97) of endoscopists preferred commercial anti-fogging agent, 7.04% (95% CI 0.94-13.14) preferred baby shampoo and 83.10% (95% CI 74.16-92.03) had equal satisfaction. Both agents had no statistically significant difference for preventing foggy on the lens. Baby shampoo is an effective agent to prevent fogging during nasal endoscopy and comparable with the commercial anti-fogging agent.

  20. Viability of single balloon enteroscopy performed under endoscopist-directed sedation.

    PubMed

    López Rosés, Leopoldo; Álvarez, Beatriz; González Ramírez, Abel; López Baz, Alina; Fernández López, Alexia; Alonso, Sara; Dacal, Andrés; Martí, Eva; Albines, Gino; Fernández Molina, Julieta; Lancho, Ángel

    2018-04-01

    there is a lot of controversy with regard to who should be responsible for sedation during digestive endoscopy, particularly in advanced procedures that require deep sedation such as enteroscopy. The aim of this study was to evaluate the endoscopist-directed sedation viability during single balloon enteroscopy. this was a prospective, observational study of a series of consecutive enteroscopies. The clinical staff included an endoscopist, scrub nurse and a nurse in charge of monitoring and sedative administration. The following parameters were monitored: pulse oximetry, blood pressure (every five minutes), electrocardiogram and respiratory rate. There was continuous supplemental oxygen and CO2 insufflation. The patient was in the left lateral decubitus position and a fluoroscopic control was used. forty-four explorations were performed in 39 patients, 24 were male and 15 female. The median age was 74 (18-89) and the ASA score was I in 12 cases, II in 23 cases and III in nine cases. Comorbidities were present in 68% of cases. The drugs used included propofol in 23 cases, propofol and midazolam in ten cases, propofol/midazolam/fentanyl in two cases, propofol and fentanyl in two cases, and midazolam/fentanyl in seven cases. All procedures were complete. The length of the procedure was 52 minutes (20-120). There were diagnostic findings in 65.9% of cases and therapeutic measures in 47.7%. There were no severe complications and the rate of complications derived from sedation was 22.7%. endoscopist-directed sedation is effective and safe for single balloon enteroscopy. Multi-center and wider studies are needed in order to better assess the efficacy, safety and efficiency of sedation controlled by a non-anesthetist during advanced endoscopy in this field.

  1. A novel balloon colonoscope detects significantly more simulated polyps than a standard colonoscope in a colon model.

    PubMed

    Hasan, Nazia; Gross, Seth A; Gralnek, Ian M; Pochapin, Mark; Kiesslich, Ralf; Halpern, Zamir

    2014-12-01

    Although standard colonoscopy is considered the optimal test to detect adenomas, it can have a significant adenoma miss rate. A major contributing factor to high miss rates is the inability to visualize adenomas behind haustral folds and at anatomic flexures. To compare the diagnostic yield of balloon-assisted colonoscopy versus standard colonoscopy in the detection of simulated polyps in a colon model. Prospective, cohort study. International gastroenterology meeting. A colon model composed of elastic material, which mimics the flexible structure of haustral folds, allowing for dynamic responses to balloon inflation, with embedded simulated colon polyps (n = 12 silicone "polyps"). Fifty gastroenterologists were recruited to identify simulated colon polyps in a colon model, first using standard colonoscopy immediately followed by balloon-assisted colonoscopy. Detection of simulated polyps. The median polyp detection rate for all simulated polyps was significantly higher with balloon-assisted as compared with standard colonoscopy (91.7% vs 45.8%, respectively; P < .0001). The significantly higher simulated polyp detection rate with balloon-assisted versus standard colonoscopy was notable both for non-obscured polyps (100.0% vs 75.0%; P < .0001) and obscured polyps (88.0% vs 25.0%; P < .0001). Non-randomized design, use of a colon model, and simulated colon polyps. As compared with standard colonoscopy, balloon-assisted colonoscopy detected significantly more obscured and non-obscured simulated polyps in a colon model. Clinical studies in human participants are being pursued to further evaluate this new colonoscopic technology. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  2. Factors associated with complications or failure of endoscopic balloon dilation of anastomotic stricture secondary to Roux-en-Y gastric bypass surgery.

    PubMed

    de Moura, Eduardo G H; Orso, Ivan R B; Aurélio, Eduardo F; de Moura, Eduardo T H; de Moura, Diogo T H; Santo, Marco A

    2016-01-01

    Roux-en-Y gastric bypass is a commonly used technique of bariatric surgery. One of the most important complications is gastrojejunal anastomotic stricture. Endoscopic balloon dilation appears to be well tolerated and effective, but well-designed randomized, controlled trials have not yet been conducted. Identify factors associated with complications or failure of endoscopic balloon dilation of anastomotic stricture secondary to Roux-en-Y gastric bypass surgery. Gastrointestinal endoscopy service, university hospital, Brazil. The records of 64 patients with anastomotic stricture submitted to endoscopic dilation with hydrostatic balloon dilation were reviewed. Information was collected on gastric pouch length, anastomosis diameter before dilation, number of dilation sessions, balloon diameter at each session, anastomosis diameter after the last dilation session, presence of postsurgical complications, endoscopic complications, and outcome of dilation. Comparisons were made among postsurgical and endoscopic complications; number of dilations, balloon diameter; anastomosis diameter before dilation; and dilation outcome. Success of dilation treatment was 95%. Perforation was positively and significantly associated with the number of dilation sessions (P = .03). Highly significant associations were found between ischemic segment and perforation (P<.001) and between ischemic segment and bleeding (P = .047). Ischemic segment (P = .02) and fistula (P = .032) were also associated with dilation failure. Ischemic segment and fistula were found to be important risk factors for balloon dilation failure. The greater the number of dilation sessions, the greater the number of endoscopic complications. Copyright © 2016 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  3. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment

    PubMed Central

    Do, Thanh Nho; Seah, Tian En Timothy; Yu, Ho Khek; Phee, Soo Jay

    2016-01-01

    Intra-gastric balloons (IGB) have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient’s stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient’s stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm) is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight. PMID:26815309

  4. Flexible endoscopy for pediatric tracheobronchial metallic stent placement, maintenance and long-term outcomes

    PubMed Central

    2018-01-01

    Objectives To assess the placement, surveillance management and long-term outcomes of the tracheobronchial (TB) balloon expandable metallic stent (BEMS) managed by therapeutic flexible endoscopy (TFE). Methods This is a retrospective review and analysis of all computerized medical records and related flexible endoscopy videos of pediatric patients who received TB BEMS during 20 years period, from January 1997 to December 2016. TFE techniques with forceps debridement, balloon dilatation and laser ablation were used to implant stents, perform regular surveillance, maintain their functions, and expand the diameters of BEMS. Short-length (30cm-36cm) endoscopes of OD 3.2mm to 5.0mm coupled with the noninvasive ventilation, without ventilation bag, mask or airway tube, supported the whole procedures. Results 146 BEMS were implanted in 87 consecutive children, including 84 tracheal, 15 carinal and 47 bronchial stents. At the time of placement, the mean age was 35.6 ± 54.6 month-old (range 0.3–228) and the mean body weight was 13.9 ± 10.6 kg (range 2.2–60). Surveillance period was 9.4 ± 6.7 years (range, 0.3–18.0). Satisfactory clinical improvements were noted immediately in all but two patients. Seventy-two (82.8%) patients were still alive with stable respiratory status, except two patients necessitating TFE management every two months. Fifty-one stents, including 35 tracheal and 16 bronchial ones, were successfully retrieved mainly with rigid endoscopy. Implanted stents could be significantly (< .001) further expanded for growing TB lumens. The final stent diameters were positively correlated to the implanted duration. Altogether, 33 stents expired (15 patients), 51 were retrieved (40 patients), and 62 remained and functioning well (38 patients), with their mean duration of 7.4 ± 9.5, 34.9 ± 36.3 and 82.3 ± 62.5 months, respectively. Conclusion In pediatric patients, TFE with short-length scopes coupled with this NIV support has provided a safe, feasible and effective modality in placing and subsequently managing TB BEMS with acceptable long-term outcomes. PMID:29420596

  5. The add-on N-acetylcysteine is more effective than dimethicone alone to eliminate mucus during narrow-band imaging endoscopy: a double-blind, randomized controlled trial.

    PubMed

    Chen, Ming-Jen; Wang, Horng-Yuan; Chang, Chen-Wang; Hu, Kuang-Chun; Hung, Chien-Yuan; Chen, Chih-Jen; Shih, Shou-Chuan

    2013-02-01

    Recent studies have shown that pronase can improve mucosal visibility, but this agent is not uniformly available for human use worldwide. This study aimed to assess the efficacy of N-acetylcysteine (NAC), a mucolytic agent, in improving mucus elimination as measured by decreased endoscopic water flushes during narrow-band imaging (NBI) endoscopy. A consecutive series of patients scheduled for upper gastrointestinal endoscopy at outpatient clinics were enrolled in this double-blind, randomized controlled trial. The control group drank a preparation of 100 mg dimethicone (5 ml at 20 mg/ml) plus water up to 100 ml, and the NAC group drank 300 mg NAC plus 100 mg dimethicone and water up to 100 ml. During the endoscopy, the endoscopist used as many flushes of water as deemed necessary to produce a satisfactory NBI view of the entire gastric mucosa. In all, 177 patients with a mean age of 51 years were evaluated in this study. Significantly lesser water was used for flushing during NBI endoscopy for the NAC group than the control group; 40 ml (30-70, 0-120) versus 50 ml (30-100, 0-150) (median (interquartile range, range), p = 0.0095). Considering the safety profile of NAC, decreasing the number of water flushes for optimal vision and unavailability of pronase in some areas, the authors suggest the use of add-on NAC to eliminate mucus during NBI endoscopy.

  6. Endoscopic management of difficult common bile duct stones

    PubMed Central

    Trikudanathan, Guru; Navaneethan, Udayakumar; Parsi, Mansour A

    2013-01-01

    Endoscopy is widely accepted as the first treatment option in the management of bile duct stones. In this review we focus on the alternative endoscopic modalities for the management of difficult common bile duct stones. Most biliary stones can be removed with an extraction balloon, extraction basket or mechanical lithotripsy after endoscopic sphincterotomy. Endoscopic papillary balloon dilation with or without endoscopic sphincterotomy or mechanical lithotripsy has been shown to be effective for management of difficult to remove bile duct stones in selected patients. Ductal clearance can be safely achieved with peroral cholangioscopy guided laser or electrohydraulic lithotripsy in most cases where other endoscopic treatment modalities have failed. Biliary stenting may be an alternative treatment option for frail and elderly patients or those with serious co morbidities. PMID:23345939

  7. Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varices: Concept, Basic Techniques, and Outcomes

    PubMed Central

    Saad, Wael E. A.

    2012-01-01

    Patients with gastric variceal bleeding require a multidisciplinary team approach including hepatologists, endoscopists, diagnostic radiologists, and interventional radiologists. Upper gastrointestinal endoscopy is the first-line diagnostic and management tool for bleeding gastric varices, as it is in all upper gastrointestinal bleeding scenarios. In the United States when endoscopy fails to control gastric variceal bleeding, a transjugular intrahepatic portosystemic shunt (TIPS) traditionally is performed along the classic teachings of decompressing the portal circulation. However, TIPS has not shown the same effectiveness in controlling gastric variceal bleeding that it has with esophageal variceal bleeding. For the past 2 decades, the balloon-occluded retrograde transvenous obliteration (BRTO) procedure has become common practice in Asia for the management of gastric varices. BRTO is gaining popularity in the United States. It has been shown to be effective in controlling gastric variceal bleeding with low rebleed rates. BRTO has many advantages over TIPS in that it is less invasive and can be performed on patients with poor hepatic reserve and those with encephalopathy (and may even improve both). However, its by-product is occlusion of a spontaneous hepatofugal (TIPS equivalent) shunt, and thus it is contradictory to the traditional American doctrine of portal decompression. Indeed, BRTO causes an increase in portal hypertension, with potential aggravation of esophageal varices and ascites. This article discusses the concept, technique, and outcomes of BRTO within the broader management of gastric varices. PMID:23729982

  8. Double Guiding Catheters for Complex Percutaneous Coronary Intervention

    PubMed Central

    Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen

    2012-01-01

    A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243

  9. Antigravity ESD - double-balloon-assisted underwater with traction hybrid technique.

    PubMed

    Sharma, Sam K; Hiratsuka, Takahiro; Hara, Hisashi; Milsom, Jeffrey W

    2018-06-01

     Complex colorectal polyps or those positioned in difficult anatomic locations are an endoscopic therapeutic challenge. Underwater endoscopic submucosal dissection (UESD) is a potential technical solution to facilitate efficient polyp removal. In addition, endoscopic tissue retraction has been confined to limited methods of varying efficacy and complexity. The aim of this study was to evaluate the efficiency of a unique UESD technique for removing complex polyps using double-balloon-assisted retraction (R).  Using fresh ex-vivo porcine rectum, 4-cm polyps were created using electrosurgery and positioned at "6 o'clock" within an established ESD model. Six resections were performed in each group. Underwater techniques were facilitated using a novel double-balloon platform (Dilumen, Lumendi, Westport, Connecticut, United States).  UESD-R had a significantly shorter total procedural time than cap-assisted ESD and UESD alone (24 vs. 58 vs. 56 mins). UESD-R produced a dissection time on average of 5 minutes, attributed to the retraction provided. There was also a subjective significant reduction in electrosurgical smoke with the underwater techniques contributing to improved visualization.  Here we report the first ex-vivo experience of a unique double-balloon endoscopic platform optimized for UESD with tissue traction capability. UESD-R removed complex lesions in significantly shorter time than conventional means. The combined benefits of UESD and retraction appeared to be additive when tackling complex polyps and should be studied further.

  10. Primary intestinal lymphangiectasia diagnosed by double-balloon enteroscopy and treated by medium-chain triglycerides: a case report.

    PubMed

    Lai, Yu; Yu, Tao; Qiao, Xiao-Yu; Zhao, Li-Na; Chen, Qi-Kui

    2013-01-14

    Primary intestinal lymphangiectasia is a disorder characterized by exudative enteropathy resulting from morphologic abnormalities of the intestinal lymphatics. Intestinal lymphangiectasia can be primary or secondary, so the diagnosis of primary intestinal lymphangiectasia must first exclude the possibility of secondary intestinal lymphangiectasia. A double-balloon enteroscopy and biopsy, as well as the pathology can be used to confirm the diagnosis of intestinal lymphangiectasia. A polymeric diet containing medium-chain triglycerides and total parenteral nutrition may be a useful therapy. A 17-year-old girl of Mongoloid ethnicity was admitted to our hospital with a history of diarrhea and edema. She was diagnosed with protein-losing enteropathy caused by intestinal lymphangiectasia. This was confirmed by a double-balloon enteroscopy and multi-dot biopsy. After treatment with total parenteral nutrition in hospital, which was followed by a low-fat and medium-chain triglyceride diet at home, she was totally relieved of her symptoms. Intestinal lymphangiectasia can be diagnosed with a double-balloon enteroscopy and multi-dot biopsy, as well as the pathology of small intestinal tissue showing edema of the submucosa and lymphangiectasia. Because intestinal lymphangiectasia can be primary or secondary, the diagnosis of primary intestinal lymphangiectasia must first exclude the possibility of secondary intestinal lymphangiectasia. A positive clinical response to the special diet therapy, namely a low-fat and medium-chain triglyceride diet, can further confirm the diagnosis of primary intestinal lymphangiectasia.

  11. Update on imaging of Peutz-Jeghers syndrome

    PubMed Central

    Tomas, Catherine; Soyer, Philippe; Dohan, Anthony; Dray, Xavier; Boudiaf, Mourad; Hoeffel, Christine

    2014-01-01

    Peutz-Jeghers syndrome (PJS) is a rare, autosomal dominant disease linked to a mutation of the STK 11 gene and is characterized by the development of benign hamartomatous polyps in the gastrointestinal tract in association with a hyperpigmentation on the lips and oral mucosa. Patients affected by PJS have an increased risk of developing gastrointestinal and extra-digestive cancer. Malignancy most commonly occurs in the small-bowel. Extra-intestinal malignancies are mostly breast cancer and gynecological tumors or, to a lesser extent, pancreatic cancer. These polyps are also at risk of acute gastrointestinal bleeding, intussusception and bowel obstruction. Recent guidelines recommend regular small-bowel surveillance to reduce these risks associated with PJS. Small-bowel surveillance allows for the detection of large polyps and the further referral of selected PJS patients for endoscopic enteroscopy or surgery. Video capsule endoscopy, double balloon pushed enteroscopy, multidetector computed tomography and magnetic resonance enteroclysis or enterography, all of which are relatively new techniques, have an important role in the management of patients suffering from PJS. This review illustrates the pathological, clinical and imaging features of small-bowel abnormalities as well as the role and performance of the most recent imaging modalities for the detection and follow-up of PJS patients. PMID:25152588

  12. Standard and double-dose intravenous proton pump inhibitor injections for prevention of bleeding after endoscopic resection.

    PubMed

    Jung, Sung Woo; Kim, Seung Young; Choe, Jung Wan; Hyun, Jong Jin; Jung, Young Kul; Koo, Ja Seol; Yim, Hyung Joon; Lee, Sang Woo

    2017-04-01

    Endoscopic resection is commonly used to remove gastric neoplasms. However, effective dosing or scheduling of proton pump inhibitors for the prevention of delayed bleeding after endoscopic resection remains unclear. One hundred sixty-six patients with gastric adenoma or early gastric cancer were enrolled. After an endoscopic procedure, each subject was randomly assigned to 40 mg every 24 h (standard dose group) or 40 mg every 12 h (double-dose group) of intravenous pantoprazole for 48 h. Second-look endoscopy was performed on day 2 after endoscopic resection to compare signs of rebleeding and ulcer status between the two groups. Eighty-one patients of the standard dose group and 81 of the double-dose group were analyzed. There were no significant differences in the incidence of delayed bleeding events (1.3% vs 6.2%, P = 0.21) and bleeding ulcer at the second-look endoscopy (6.2% vs 3.9%, P = 0.69) between standard and double-dose groups. There were no other significant variables associated with delayed bleeding or bleeding ulcer on second-look endoscopy. Intravenous pantoprazole 40 mg every 24 h or 12 h for 2 days after endoscopic resection was equally effective for the prevention of delayed bleeding. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  13. Peritoneal Lipomatosis: A Case Report of a 12-Year-Old Boy

    PubMed Central

    Fotis, L.; Koglmeier, J.; Shah, N.

    2013-01-01

    Peritoneal lipomatosis is a rare disease in childhood with only two cases previously described in children. We report a further case of a 12-year-old boy diagnosed with peritoneal lipomatosis. His main symptoms were abdominal pain, alternating bowel habit, abdominal distension, and melaena. His diagnostic work up included an abdominal MRI, wireless capsule endoscopy and single-balloon enteroscopy. Peritoneal lipomatosis although rare can be diagnosed in childhood. It is a benign clinical entity with variable manifestations. PMID:23762668

  14. Primary Jejunal Adenocarcinoma Presenting as Bilateral Ovarian Metastasis

    PubMed Central

    Ofori, Emmanuel; Ramai, Daryl; Papafragkakis, Charilaos; Changela, Kinesh; Krishnaiah, Mahesh

    2017-01-01

    Small intestinal tumors are rare with adenocarcinoma of the small intestine accounting for less than 2% of all gastrointestinal cancers. Primary jejunal adenocarcinoma constitutes a minute portion of small intestine adenocarcinomas. Clinically, this cancer presents at latter stages of its progression, mainly due to vague and non-specific symptoms, and the difficulty encountered in accessing the jejunum on upper endoscopy. Diagnosis of jejunal adenocarcinoma is usually inconclusive with the use of computed tomography (CT) scan, small bowel series, or upper endoscopy. Laparoscopy followed by frozen section biopsy provides a definitive diagnosis. In the past decade, balloon-assisted enteroscopy (BAE) and capsule endoscopy have become popular as useful modalities for diagnosing small bowel diseases. Wide excisional jejunectomy is the only treatment option with an estimated 5-year survival of 40-65%. Physicians are advised to suspect jejunal adenocarcinoma as a differential diagnosis in patients who present with non-specific symptoms of abdominal pain, nausea, vomiting, weight loss, anemia, gastrointestinal bleeding or signs of small bowel obstruction. We present a rare case of a 37-year-old woman with suspected bilateral ovarian masses, which was immunohistochemically confirmed as primary jejunal adenocarcinoma with bilateral ovarian metastasis. PMID:29317945

  15. Primary Jejunal Adenocarcinoma Presenting as Bilateral Ovarian Metastasis.

    PubMed

    Ofori, Emmanuel; Ramai, Daryl; Papafragkakis, Charilaos; Changela, Kinesh; Krishnaiah, Mahesh

    2017-12-01

    Small intestinal tumors are rare with adenocarcinoma of the small intestine accounting for less than 2% of all gastrointestinal cancers. Primary jejunal adenocarcinoma constitutes a minute portion of small intestine adenocarcinomas. Clinically, this cancer presents at latter stages of its progression, mainly due to vague and non-specific symptoms, and the difficulty encountered in accessing the jejunum on upper endoscopy. Diagnosis of jejunal adenocarcinoma is usually inconclusive with the use of computed tomography (CT) scan, small bowel series, or upper endoscopy. Laparoscopy followed by frozen section biopsy provides a definitive diagnosis. In the past decade, balloon-assisted enteroscopy (BAE) and capsule endoscopy have become popular as useful modalities for diagnosing small bowel diseases. Wide excisional jejunectomy is the only treatment option with an estimated 5-year survival of 40-65%. Physicians are advised to suspect jejunal adenocarcinoma as a differential diagnosis in patients who present with non-specific symptoms of abdominal pain, nausea, vomiting, weight loss, anemia, gastrointestinal bleeding or signs of small bowel obstruction. We present a rare case of a 37-year-old woman with suspected bilateral ovarian masses, which was immunohistochemically confirmed as primary jejunal adenocarcinoma with bilateral ovarian metastasis.

  16. EUS-guided gastroenterostomy: a multicenter study comparing the direct and balloon-assisted techniques.

    PubMed

    Chen, Yen-I; Kunda, Rastislav; Storm, Andrew C; Aridi, Hanaa Dakour; Thompson, Christopher C; Nieto, Jose; James, Theodore; Irani, Shayan; Bukhari, Majidah; Gutierrez, Olaya Brewer; Agarwal, Amol; Fayad, Lea; Moran, Robert; Alammar, Nuha; Sanaei, Omid; Canto, Marcia I; Singh, Vikesh K; Baron, Todd H; Khashab, Mouen A

    2018-05-01

    EUS-guided gastroenterostomy (EUS-GE) is a developing modality in the management of gastric outlet obstruction (GOO) with several technical approaches, including the direct and balloon-assisted techniques. The aim of this study was to compare the direct with the balloon-assisted modality while further defining the role of EUS-GE in GOO. This multicenter, retrospective study involved consecutive patients who underwent EUS-GE with the direct or balloon-assisted technique for GOO (January 2014 to October 2016). The primary outcome was technical success. Secondary outcomes were success (ability to tolerate at least a full fluid diet), procedure time, and rate/severity of adverse events (AEs). A total of 74 patients (44.6% women; mean age 63.0 ± 11.7 years) underwent EUS-GE for GOO (direct gastroenterostomy, n = 52; balloon-assisted gastroenterostomy, n = 22). GOO was of malignant and benign etiology in 66.2% and 33.8% of patients, respectively. Technical success was achieved in 94.2% of the direct and 90.9% of the balloon-assisted approach (P = .63). Mean procedure time was shorter with the direct technique (35.7 ± 32.1 minutes vs 89.9 ± 33.3 minutes, P < .001). The clinical success rate was 92.3% for the direct technique and 90.9% for the balloon-assisted modality (P = 1.00), with a mean time to oral intake of 1.32 ± 2.76 days. The AE rate was 6.8% with only 1 severe AE noted. Rate of AEs, postprocedure length of stay, need for reintervention, and survival were similar between the 2 groups. EUS-GE is effective and safe in the management of GOO. The direct technique may be the preferred method given its shorter procedure time when compared with the balloon-assisted approach. Prospective trials are needed to confirm these findings. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  17. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis--Report of 7 Consecutive Patients with Serial ERC Approach.

    PubMed

    Stojkovic, Marija; Junghanss, Thomas; Veeser, Mira; Weber, Tim F; Sauer, Peter

    2016-02-01

    Biliary vessel pathology due to alveolar echicococcosis (AE) results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography) balloon dilation for AE biliary pathology. Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed. Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed "sustained clinical success" and four patients "assisted therapeutic success," of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS). There was no loss to follow up. No major complications were observed. Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current ERC guidelines and is minimally disruptive for patients.

  18. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis – Report of 7 Consecutive Patients with Serial ERC Approach

    PubMed Central

    Stojkovic, Marija; Junghanss, Thomas; Veeser, Mira; Weber, Tim F.; Sauer, Peter

    2016-01-01

    Background and Aims Biliary vessel pathology due to alveolar echicococcosis (AE) results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography) balloon dilation for AE biliary pathology. Methods Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed. Results Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed “sustained clinical success” and four patients “assisted therapeutic success,” of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS). There was no loss to follow up. No major complications were observed. Conclusions Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current ERC guidelines and is minimally disruptive for patients. PMID:26910822

  19. Comparison of the efficacy of intravenous tranexamic acid with and without topical administration versus placebo in urgent endoscopy rate for acute gastrointestinal bleeding: A double-blind randomized controlled trial

    PubMed Central

    Tavakoli, Nader; Agah, Shahram; Azizi, Ali; Masoodi, Mohsen; Amiri, Hassan; Sheikhvatan, Mehrdad; Syedsalehi, Bahare; Behnam, Behdad; Arabahmadi, Mehran; Mehrazi, Maryam

    2017-01-01

    Background Tranexamic acid (TXA), a synthetic antifibrinolytic drug, is effective as a treatment for serious hemorrhage, including bleeding arising from major trauma and post-operative interventions. Significant acute gastrointestinal bleeding may have a poor outcome despite routine medical and endoscopic treatments. The aim of this study was to assess whether early intravenous and/or intravenous plus topical administration of TXA reduces the need for urgent endoscopy for acute gastrointestinal bleeding. Method This double-blind randomized clinical trial included 410 patients with proven acute gastrointestinal bleeding. All patients received conventional therapy. The subjects were randomized to three groups: (A) 138 patients received intravenous TXA (1 g q6h); (B) 133 patients received topical TXA (1 g single dose by nasogastric tube) plus systemic TXA; and (C) 139 patients received a placebo (sodium chloride 0.9%) for 24 hours. Subgroup statistical analyses were conducted for urgent endoscopy, mortality, re-bleeding, blood transfusion, endoscopic and/or surgical intervention rates, and health status. Results The time to endoscopy was significantly shorter in group C (15.58 ± 7.994, p < 0.001). A need for urgent endoscopy was seen in 14.49%, 10.52%, and 30.21% of patients in groups A, B, and C, respectively (p < 0.001). No significant statistical differences were seen between treatment groups regarding mortality, re-bleeding, blood transfusion, and endoscopic and/or surgical intervention rates. No thromboembolic event was documented during the 1-week follow up. Conclusions Our results showed that the antifibrinolytic properties of TXA can aid in changing an urgent endoscopy to an elective procedure, with better outcomes for both physicians and patients. PMID:29435313

  20. Percutaneous Mitral Valve Dilatation: Single Balloon versus Double Balloon - A Finite Element Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schievano, Silvia; Kunzelman, Karyn; Nicosia, Mark

    2009-01-01

    Background: Percutaneous mitral valve (MV) dilatation is performed with either a single balloon (SB) or double balloon (DB) technique. The aim of this study was to compare the two balloon system results using the finite element (FE) method. Methods and Results: An established FE model of the MV was modified by fusing the MV leaflet edges at commissure level to simulate a stenotic valve (orifice area=180mm2). A FE model of a 30mm SB (low-pressure, elastomeric balloon) and an 18mm DB system (high-pressure, non-elastic balloon) was created. Both SB and DB simulations resulted in splitting of the commissures and subsequent stenosismore » dilatation (final MV area=610mm2 and 560mm2 respectively). Stresses induced by the two balloon systems varied across the valve. At the end of inflation, SB showed higher stresses in the central part of the leaflets and at the commissures compared to DB simulation, which demonstrated a more uniform stress distribution. The higher stresses in the SB analysis were due to the mismatch of the round balloon shape with the oval mitral orifice. The commissural split was not easily accomplished with the SB due to its high compliance. The high pressure applied to the DB guaranteed the commissural split even when high forces were required to break the commissure welds. Conclusions: The FE model demonstrated that MV dilatation can be accomplished by both SB and DB techniques. However, the DB method resulted in higher probability of splitting of the fused commissures and less damage caused to the MV leaflets by overstretching.« less

  1. Primary intestinal lymphangiectasia diagnosed by double-balloon enteroscopy and treated by medium-chain triglycerides: a case report

    PubMed Central

    2013-01-01

    Introduction Primary intestinal lymphangiectasia is a disorder characterized by exudative enteropathy resulting from morphologic abnormalities of the intestinal lymphatics. Intestinal lymphangiectasia can be primary or secondary, so the diagnosis of primary intestinal lymphangiectasia must first exclude the possibility of secondary intestinal lymphangiectasia. A double-balloon enteroscopy and biopsy, as well as the pathology can be used to confirm the diagnosis of intestinal lymphangiectasia. A polymeric diet containing medium-chain triglycerides and total parenteral nutrition may be a useful therapy. Case presentation A 17-year-old girl of Mongoloid ethnicity was admitted to our hospital with a history of diarrhea and edema. She was diagnosed with protein-losing enteropathy caused by intestinal lymphangiectasia. This was confirmed by a double-balloon enteroscopy and multi-dot biopsy. After treatment with total parenteral nutrition in hospital, which was followed by a low-fat and medium-chain triglyceride diet at home, she was totally relieved of her symptoms. Conclusion Intestinal lymphangiectasia can be diagnosed with a double-balloon enteroscopy and multi-dot biopsy, as well as the pathology of small intestinal tissue showing edema of the submucosa and lymphangiectasia. Because intestinal lymphangiectasia can be primary or secondary, the diagnosis of primary intestinal lymphangiectasia must first exclude the possibility of secondary intestinal lymphangiectasia. A positive clinical response to the special diet therapy, namely a low-fat and medium-chain triglyceride diet, can further confirm the diagnosis of primary intestinal lymphangiectasia. PMID:23316917

  2. Success of single-balloon enteroscopy in patients with surgically altered anatomy.

    PubMed

    Kurzynske, Frank C; Romagnuolo, Joseph; Brock, Andrew S

    2015-08-01

    Single-balloon enteroscopy (SBE) was introduced in 2007 to diagnose and treat small-bowel disorders. No study to date has evaluated SBE in patients with surgically altered anatomy outside of ERCP. To evaluate the efficacy, yield, and safety of SBE in patients with surgically altered anatomy. Retrospective study. Tertiary-care academic medical center. All patients with altered surgical anatomy who underwent SBE at the Medical University of South Carolina from July 2007 to September 2013. SBE. Diagnostic yield, therapeutic yield, technical success, and adverse events. A total of 48 patients met inclusion criteria. Mean age was 56 years (77% female). Eleven patients underwent single-balloon PEG placement, 8 single-balloon ERCP, 22 non-PEG/non-ERCP anterograde SBE, and 7 retrograde SBE. Previous surgeries included Roux-en-Y gastric bypass (n=26), small-intestine resection (n=6), colon resection (n=5), Whipple procedure (n=4), choledochojejunostomy (n=3), hepaticojejunostomy (n=1), Billroth I (n=1), Billroth II (n=1), and Puestow procedure (n=1). Procedural indications were PEG tube placement (n=11), choledocholithiasis (n=2), biliary stricture (n=2), obstructive jaundice (n=1), cholangitis (n=1), ampullary mass (n=1), sphincter of Oddi dysfunction (n=1), anemia and/or bleeding (n=15), abdominal pain (n=9), radiologic evidence of obstruction (n=3), and Peutz-Jeghers syndrome (n=2). The technical success rate was 73% in single-balloon PEG placement, 88% in single-balloon ERCP, 82% in other anterograde SBEs, and 86% in retrograde SBEs. No intraprocedural or postprocedural adverse events were observed. Single center, retrospective study. SBE is safe and effective in patients with surgically altered anatomy. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  3. Expanding Role of Third Space Endoscopy in the Management of Esophageal Diseases.

    PubMed

    Yang, Dennis; Draganov, Peter V

    2018-03-01

    OPINION STATEMENT: "Third space" endoscopy, also commonly referred as submucosal endoscopy, is founded on the principle that the deeper layers of the gastrointestinal (GI) tract can be accessed by tunneling in the submucosal space without compromising the integrity of the overlying mucosa. Peroral endoscopic myotomy (POEM), endoscopic submucosal dissection (ESD), and submucosal tunneling endoscopic resection (STER) are innovative techniques within the field of third space endoscopy in the management of esophageal disorders. POEM has become an accepted minimally invasive therapy for achalasia and related motility disorders with excellent short-term results, with early studies yielding similar efficacy to surgical myotomy and increased durability when compared to pneumatic balloon dilation (PBD). Data are needed to establish long-term outcomes with POEM, with particular interest on the incidence of gastroesophageal reflux, which appears to be higher than initially anticipated. ESD, a mature endoscopic resection technique in Asia, has recently gained traction in the West as a viable option for the management of early Barrett's esophagus (BE) neoplasia. Compared to standard endoscopic mucosal resection (EMR), ESD allows the en bloc resection of lesions irrespective of size, which may facilitate histological interpretation and reduce recurrence rates. Large prospective randomized controlled trials are needed to validate the efficacy and safety of this technique and to further define its role in the endoscopic armamentarium in early BE neoplasia. STER is an attractive technique that theoretically permits the resection of subepithelial esophageal tumors (SETs) arising from the deeper GI layers. Initial studies from highly experienced endoscopic centers support its technical feasibility and safety, although these results should be interpreted with caution due to variability arising from small numbers and heterogeneity among studies. Overall, third space endoscopy is an expanding field within endoscopic therapeutics for the treatment of esophageal diseases. While initial results have been very promising, large prospective studies, long-term data, and structured training programs with the establishment of competency parameters are needed before third space endoscopy can be advocated outside of highly specialized centers.

  4. Secondary lymphangiectasia of the small bowel: utility of double balloon enteroscopy for diagnosis and management.

    PubMed

    Safatle-Ribeiro, Adriana Vaz; Iriya, Kiyoshi; Couto, Décio Sampaio; Kawaguti, Fábio Shiguehiss; Retes, Felipe; Ribeiro, Ulysses; Sakai, Paulo

    2008-01-01

    Sporadic lymphangiectasias are commonly found throughout the small bowel and are considered to be normal. Not uncommonly, lymphangiectasias are pathologic and can lead to mid-gastrointestinal bleeding, abdominal pain and protein-losing enteropathy. Pathologic lymphangiectasias of the small bowel include primary lymphangiectasia, secondary lymphangiectasia and lymphaticovenous malformations. In this report we present three different cases of small bowel lymphangiectasia detected by double balloon enteroscopy. The patients were diagnosed with South American blastomycosis, tuberculosis and primary small bowel lymphangioma. 2009 S. Karger AG, Basel

  5. Benign Post-Radiation Rectal Stricture Treated with Endoscopic Balloon Dilation and Intralesional Triamcinolone Injection

    PubMed Central

    Karanikas, Michael; Touzopoulos, Panagiotis; Mitrakas, Alexandros; Zezos, Petros; Zarogoulidis, Paul; Machairiotis, Nikolaos; Efremidou, Eleni; Liratzopoulos, Nikolaos; Polychronidis, Alexandros; Kouklakis, George

    2012-01-01

    Post-radiation stricture is a rare complication after pelvis irradiation, but must be in the mind of the clinician evaluating a lower gastrointestinal obstruction. Endoscopy has gained an important role in chronic radiation proctitis with several therapeutic options for management of intestinal strictures. The treatment of rectal strictures has been limited to surgery with high morbidity and mortality. Therefore, a less invasive therapeutic approach for benign rectal strictures, endoscopic balloon dilation with or without intralesional steroid injection, has become a common treatment modality. We present a case of benign post-radiation rectal stricture treated successfully with balloon dilation and adjuvant intralesional triamcinolone injection. A 70-year-old woman presented to the emergency room complaining for 2 weeks of diarrhea and meteorism, 11 years after radiation of the pelvis due to adenocarcinoma of the uterus. Colonoscopy revealed a stricture at the rectum and multiple endoscopic biopsies were obtained from the stricture. The stricture was treated with endoscopic balloon dilation and intralesional triamcinolone injection. The procedure appears to have a high success rate and a very low complication rate. Histologic examination of the biopsies revealed non-specific inflammatory changes of the rectal mucosa and no specific changes of the mucosa due to radiation. All biopsies were negative for malignancy. The patient is stricture-free 12 months post-treatment. PMID:23271987

  6. Endoscopy-guided balloon dilation of benign anastomotic strictures after radical gastrectomy for gastric cancer.

    PubMed

    Lee, Hyun Jik; Park, Wan; Lee, Hyuk; Lee, Keun Ho; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan; Noh, Sung Hoon

    2014-07-01

    The aim of this study was to evaluate the outcome of endoscopic dilation for benign anastomotic stricture after radical gastrectomy in gastric cancer patients. Gastric cancer patients who underwent endoscopic balloon dilation for benign anastomosis stricture after radical gastrectomy during a 6-year period were reviewed retrospectively. Twenty-one patients developed benign strictures at the site of anastomosis. The majority of strictures occurred within 1 year after surgery (95.2%). The median duration to stenosis after surgery was 1.70 months (range, 0.17 to 23.97 months). The success rate of the first endoscopic dilation was 61.9%. Between the restenosis group (n=8) and the no restenosis group (n=13), there were no significant differences in the body mass index (22.82 kg/m(2) vs 22.46 kg/m(2)), interval to symptom onset (73.9 days vs 109.3 days), interval to treatment (84.6 days vs 115.6 days), maximal balloon diameter (14.12 mm vs 15.62 mm), number of balloon dilation sessions (1.75 vs 1.31), location of gastric cancer or type of surgery. One patient required surgery because of stricture refractory to repeated dilation. Endoscopic dilation is a highly effective treatment for benign anastomotic strictures after radical gastrectomy for gastric cancer and should be considered a primary intervention prior to proceeding with surgical revision.

  7. Prevention and management of non-steroidal anti-inflammatory drugs-induced small intestinal injury

    PubMed Central

    Park, Sung Chul; Chun, Hoon Jai; Kang, Chang Don; Sul, Donggeun

    2011-01-01

    Non-steroidal anti-inflammatory drug (NSAID)-induced small bowel injury is a topic that deserves attention since the advent of capsule endoscopy and balloon enteroscopy. NSAID enteropathy is common and is mostly asymptomatic. However, massive bleeding, stricture, or perforation may occur. The pathogenesis of small intestine injury by NSAIDs is complex and different from that of the upper gastrointestinal tract. No drug has yet been developed that can completely prevent or treat NSAID enteropathy. Therefore, a long-term randomized study in chronic NSAID users is needed. PMID:22180706

  8. Double-balloon enteroscopy: Indications, approaches, diagnostic and therapeutic yield, and safety. Early experience at a single center.

    PubMed

    García-Correa, J J E; Ramírez-García, J J; García-Contreras, L F; Fuentes-Orozco, C; Irusteta-Jiménez, L; Michel-Espinoza, L R; Carballo Uribe, A S; Torres Chávez, J A; González-Ojeda, A

    Double-balloon enteroscopy has been improving the visualization of the entire intestine for more than a decade. It is a complementary method in the study of intestinal diseases that enables biopsies to be taken and treatments to be administered. Our aim was to describe its main indications, insertion routes, diagnostic/therapeutic yield, and complications. All patients referred to our unit with suspected small bowel pathology were included. The insertion route (oral/anal) was determined through diagnostic suspicion. The variables measured were: insertion route, small bowel examination extent, endoscopic diagnosis/treatment, biopsy/histopathology report, complications, and surgical findings. The study included 28 double-balloon enteroscopies performed on 23 patients, of which 10 were women and 13 were men (mean age of 52.95 years). The oral approach was the most widely used (n=21), the main indication was overt small bowel bleeding (n=16), and the general diagnostic yield was 65.21%. The therapeutic intervention rate was 39.1% and the procedure was effective in all the cases. The most widely used treatment was argon plasma therapy (n=7). The complication rate was 8.6%; one patient presented with low blood pressure due to active bleeding and another had deep mucosal laceration caused by the argon plasma. Double-balloon enteroscopy is a safe and efficacious method for the study and management of small bowel diseases, with an elevated diagnostic and therapeutic yield. Copyright © 2017 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  9. Cutting Balloon Angioplasty in the Treatment of Short Infrapopliteal Bifurcation Disease.

    PubMed

    Iezzi, Roberto; Posa, Alessandro; Santoro, Marco; Nestola, Massimiliano; Contegiacomo, Andrea; Tinelli, Giovanni; Paolini, Alessandra; Flex, Andrea; Pitocco, Dario; Snider, Francesco; Bonomo, Lorenzo

    2015-08-01

    To evaluate the safety, feasibility, and effectiveness of cutting balloon angioplasty in the management of infrapopliteal bifurcation disease. Between November 2010 and March 2013, 23 patients (mean age 69.6±9.01 years, range 56-89; 16 men) suffering from critical limb ischemia were treated using cutting balloon angioplasty (single cutting balloon, T-shaped double cutting balloon, or double kissing cutting balloon technique) for 47 infrapopliteal artery bifurcation lesions (16 popliteal bifurcation and 9 tibioperoneal bifurcation) in 25 limbs. Follow-up consisted of clinical examination and duplex ultrasonography at 1 month and every 3 months thereafter. All treatments were technically successful. No 30-day death or adverse events needing treatment were registered. No flow-limiting dissection was observed, so no stent implantation was necessary. The mean postprocedure minimum lumen diameter and acute gain were 0.28±0.04 and 0.20±0.06 cm, respectively, with a residual stenosis of 0.04±0.02 cm. Primary and secondary patency rates were estimated as 89.3% and 93.5% at 6 months and 77.7% and 88.8% at 12 months, respectively; 1-year primary and secondary patency rates of the treated bifurcation were 74.2% and 87.0%, respectively. The survival rate estimated by Kaplan-Meier analysis was 82.5% at 1 year. Cutting balloon angioplasty seems to be a safe and effective tool in the routine treatment of short/ostial infrapopliteal bifurcation lesions, avoiding procedure-related complications, overcoming the limitations of conventional angioplasty, and improving the outcome of catheter-based therapy. © The Author(s) 2015.

  10. Enteroscopic Tattooing for Better Intraoperative Localization of a Bleeding Jejunal GIST Facilitates Minimally Invasive Laparoscopically-assisted Surgery.

    PubMed

    Iacob, Razvan; Dimitriu, Anca; Stanciulea, Oana; Herlea, Vlad; Popescu, Irinel; Gheorghe, Cristian

    2016-03-01

    We present the case of a 63-year-old man that was admitted for melena and severe anemia. Upper GI endoscopy and colonoscopy failed to identify the lesion responsible for bleeding, and enteroCT scan was also non-contributive to the diagnosis. Capsule endoscopy indicated possible jejunal bleeding but could not indicate the source of bleeding, recommending anterograde enteroscopy. Single balloon enteroscopy identified a 2 cm submucosal tumour in the distal part of the jejunum, with a macroscopic appearance suggesting a gastrointestinal stromal tumour (GIST). The tumor location was marked using SPOT tattoo and subsequently easily identified by the surgeon and resected via minimally invasive laparoscopic-assisted approach. Histological and immunohistochemical analysis indicated a low risk GIST. The unusual small size of the GIST as a modality of presentation, with digestive bleeding and anemia and the ability to use VCE/enteroscopy to identify and mark the lesion prior to minimally invasive surgery, represent the particularities of the presented case.

  11. Premedication with simethicone and N-acetylcysteine in improving visibility during upper endoscopy: a double-blind randomized trial.

    PubMed

    Elvas, Luís; Areia, Miguel; Brito, Daniel; Alves, Susana; Saraiva, Sandra; Cadime, Ana T

    2017-02-01

    Background and study aim  Upper endoscopy is the most common method for the diagnosis of upper gastrointestinal tract diseases. The aim of this study was to determine whether premedication with simethicone or N -acetylcysteine improves mucosal visualization during upper endoscopy. Patients and methods  This was a randomized, double-blind, placebo-controlled study of 297 patients scheduled for upper endoscopy who were premedicated 15 - 30 minutes before the procedure with: 100 mL of water (placebo, group A); water plus 100 mg simethicone (group B); water plus 100 mg simethicone plus 600 mg N -acetylcysteine (group C). The primary outcome measure was the quality of mucosal visualization (score: excellent, adequate or inadequate). Results  The addition of simethicone (group B) or simethicone plus N -acetylcysteine to the water (group C) improved the visualization scores of endoscopies compared with water alone (group A). In particular, groups B and C produced a significantly higher percentage of endoscopies with excellent visualization for the esophagus (91.1 % and 86.7 %, respectively, vs. 71.4 % in group A; P  < 0.001) and stomach (76.2 % and 74.5 % vs. 38.8 % in group A; P  < 0.001). For the duodenum, the use of simethicone also showed an increase in the endoscopies with excellent visualization compared with water alone (85.1 % vs. 73.5 %; P  = 0.042). There were no significant differences in scores between groups B and C or between gastric scores in patients with previous subtotal gastrectomy (B and C vs. A): 60.0 % and 42.1 % vs. 28.6 % ( P  = 0.14). The rate of reported lesions was higher in group B but without statistical significance. Conclusions  Premedication with simethicone resulted in better mucosal visibility. Such premedication might improve diagnostic yield, and should be considered for standard practice. Trial registered at ClinicalTrials.gov (NCT02357303). © Georg Thieme Verlag KG Stuttgart · New York.

  12. Double-lumen balloon for Onyx® embolization via extracranial arteries in transverse sigmoid dural arteriovenous fistulas: initial experience.

    PubMed

    Clarençon, Frédéric; Di Maria, Federico; Gabrieli, Joseph; Carpentier, Alexandre; Pistochi, Silvia; Bartolini, Bruno; Zeghal, Chiheb; Chiras, Jacques; Sourour, Nader-Antoine

    2016-10-01

    Transverse-sigmoid dural arteriovenous fistulas (TS DAVFs) can be challenging to treat by endovascular means. Indeed, a total cure of the fistula can only be achieved when complete occlusion of the fistulous point(s) is obtained by penetration of the embolic agent. However, in some cases, especially for transosseous branches from extracranial arteries like the occipital artery (OcA) or the superficial temporal artery (STA), such penetration is usually poor, leading to major proximal reflux and incomplete fistula obliteration. We present three cases of embolization in two patients with TS DAVF through the OcA and/or the STA with Onyx® using a double-lumen balloon (Microvention, Tustin, CA, USA). This technique allows the penetration of the embolic agent in the transosseous branches by forming a counter-pressure with the inflated balloon. This technique may be useful to achieve complete occlusion of TS DAVFs by endovascular means.

  13. Adventitial nab-rapamycin injection reduces porcine femoral artery luminal stenosis induced by balloon angioplasty via inhibition of medial proliferation and adventitial inflammation.

    PubMed

    Gasper, Warren J; Jimenez, Cynthia A; Walker, Joy; Conte, Michael S; Seward, Kirk; Owens, Christopher D

    2013-12-01

    Endovascular interventions on peripheral arteries are limited by high rates of restenosis. Our hypothesis was that adventitial injection of rapamycin nanoparticles would be safe and reduce luminal stenosis in a porcine femoral artery balloon angioplasty model. Eighteen juvenile male crossbred swine were included. Single-injury (40%-60% femoral artery balloon overstretch injury; n=2) and double-injury models (endothelial denudation injury 2 weeks before a 20%-30% overstretch injury; n=2) were compared. The double-injury model produced significantly more luminal stenosis at 28 days, P=0.002, and no difference in medial fibrosis or inflammation. Four pigs were randomized to the double-injury model and adventitial injection of saline (n=2) or 500 μg of nanoparticle albumin-bound rapamycin (nab-rapamycin; n=2) with an endovascular microinfusion catheter. There was 100% procedural success and no difference in endothelial regeneration. At 28 days, nab-rapamycin led to significant reductions in luminal stenosis, 17% (interquartile range, 12%-35%) versus 10% (interquartile range, 8.3%-14%), P=0.001, medial cell proliferation, P<0.001, and fibrosis, P<0.001. There were significantly fewer adventitial leukocytes at 3 days, P<0.001, but no difference at 28 days. Pharmacokinetic analysis (single-injury model) found rapamycin concentrations 1500× higher in perivascular tissues than in blood at 1 hour. Perivascular rapamycin persisted ≥8 days and was not detectable at 28 days. Adventitial nab-rapamycin injection was safe and significantly reduced luminal stenosis in a porcine femoral artery balloon angioplasty model. Observed reductions in early adventitial leukocyte infiltration and late medial cell proliferation and fibrosis suggest an immunosuppressive and antiproliferative mechanism. An intraluminal microinfusion catheter for adventitial injection represents an alternative to stent- or balloon-based local drug delivery.

  14. Early endoscopic balloon dilation in caustic-induced gastric injury.

    PubMed

    Kochhar, Rakesh; Poornachandra, Kuchhangi Sureshchandra; Dutta, Usha; Agrawal, Amit; Singh, Kartar

    2010-04-01

    There are no reports on endoscopic balloon dilation (EBD) for caustic-induced gastric outlet obstruction (GOO) in the acute or subacute phase. To study the efficacy of early EBD in patients with caustic-induced gastric injury. Tertiary care center in India. Retrospective analysis of data. Out of 41 patients with caustic-induced GOO who reported to us in the subacute phase between January 2001 and December 2008, 31 were treated by EBD. All 31 had ingested an acid 14.39 +/- 4.65 days earlier. EBD was achieved by using wire-guided balloons under endoscopic guidance. The balloon was negotiated across the narrowed segment and inflated for 60 seconds using a pressure gun. Balloons of incremental diameter, up to a maximum of 3 sizes, were used in each sitting. Procedural success was defined as reaching the end point of dilation (15 mm) and absence of symptoms. All 31 patients (18 male, mean age 32.06 +/- 11.04 years) could be successfully dilated. All but 1 underwent successful dilations to achieve the end point of 15 mm, requiring a median of 9 (range 3-18) dilations over a period of 7 (range 1.5-16) weeks. Complications included self-limiting pain (n = 10), bleeding at the time of the procedure (n = 9), and perforation in 1 patient (3.2%) who required surgery. Thirty patients were followed up for a median of 21 (range 3-72) months with no recurrence. Early EBD by an expert endoscopist is a safe and effective treatment modality in the management of caustic-induced GOO. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  15. [Efficiency of endoscopic treatment with intra gastric balloon in severe to morbid obesity].

    PubMed

    Houissa, Fatma; Trabelsi, Senda; Hadj Brahim, Kamel; Mouelhi, Leila; Bouzaidi, Slim; Salem, Mohamed; Mekki, Haiffa; El Jery, Kaouther; Said, Yosra; Kheder, Sana; Debbech, Radhouane; Najjar, Taoufik

    2014-12-01

    Obesity raises such a healthcare matter throughout the world. Its management is not only complex but also most often multidisciplinary. The medico-dietary treatment is of inconstant efficiency and the surgical treatment, though more efficient, presents a considerable morbidity-death rate. The endoscopic treatment through intra-gastric balloon avails a seducing alternative namely accounting for surgery preparation. To assess the efficiency of the endoscopic treatment through gastric balloon, both in the short and long term, and this is accounting for weight loss as well as tolerance. We have carried out a retrospective study including the patients suffering from severe to morbid obesity and who had a gastric balloon implemented in our Endoscopy Unit between November 2005 and December 2007. Twenty one patients were included. The average age was 32,19 ± 12,65 years with extremes of 16 and 52 years. Fifteen patients suffered from morbid obesity. The patients' average weight was 134, 52 ± 26,46 kg (extremes 88 and 194 kg). Some co-morbidity was found out with 15 patients. Te balloon implementation (Héliosphère®) was carried out with no incidents in all patients. Six months after the balloon implementation, the average weight loss was 17,5% and the average loss of over weigh was 37%. In biological level, we noted a normalisation of fasting glycaemia in 28,6 % of cases, of the cholesterolemia in 100 %, of the triglyceridemia in 33,33%, of the uraemia in 42,8% and hepatic tests in 50 % of the cases. The metabolic syndrome disappeared in 28,57 % of cases. The assessment after a 5-year-period was marked by the need to surgical treatment in 4 patients and this is due to the loss of efficiency of endoscopic treatment. A bad tolerance of gastric balloon was observed in 34 % of the cases, dominated by sicknesses. Only one patient presented incoercible sicknesses with ionic troubles as well as deshydrating requiring the precocious extraction of the balloon after 48 hours of its implementation. The endoscopic treatment through intra gastric balloon is well tolerated but efficiently limited in time. It might be recommended in preparation for a surgical treatment or in case of contre- indication or surgery refusal.

  16. Esophageal stenosis with sloughing esophagitis: A curious manifestation of graft-vs-host disease.

    PubMed

    Trabulo, Daniel; Ferreira, Sara; Lage, Pedro; Rego, Rafaela Lima; Teixeira, Gilda; Pereira, A Dias

    2015-08-14

    We report a case of a 56-year-old woman with a history of allogenic bone marrow transplantation for two years, complaining with dysphagia and weight loss. Upper endoscopy revealed esophageal stenosis and extensive mucosa sloughing. Biopsies confirmed the diagnosis of graft-vs-host disease (GVHD). Balloon dilation, corticosteroids and cyclosporin resulted in marked clinical improvement. Gastrointestinal tract is involved in the majority of patients with chronic GVHD. Esophageal manifestations are rare and include vesiculobullous disease, ulceration, esophageal webs, casts or strictures. Sloughing esophagitis along with severe stenosis requiring endoscopic dilation has never been reported in this context.

  17. Septotomy and Balloon Dilation to Treat Chronic Leak After Sleeve Gastrectomy: Technical Principles.

    PubMed

    Campos, Josemberg Marins; Ferreira, Flávio Coelho; Teixeira, André F; Lima, Jones Silva; Moon, Rena C; D'Assunção, Marco Aurélio; Neto, Manoel Galvão

    2016-08-01

    Chronic leaks after laparoscopic sleeve gastrectomy (LSG) are often difficult to treat by endoscopy metallic stent. Septotomy has been indicated as an effective procedure, but the technical aspects have not been detailed in previous publications (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007; Baretta G, Campos J, Correia S, et al., Surg Endosc 29(7):1714-20, 2015; Campos JM, Pereira EF, Evangelista LF, et al., Obes Surg 21(10):1520-9, 2011). We herein present a video (6 min) demonstrating the maneuver principles of this technique, showing it as a safe and feasible approach. A 32-year-old male, with BMI 43.4 kg/m(2), underwent LSG. On the tenth POD, he presented with a leak and initially was managed with the following approach: laparoscopic exploration, drainage, endoclips, and 20-mm balloon dilation. However, the leak remained for a period of 6 months. On the endoscopy, a septum was identified between the leak site and gastric pouch, so it was decided to "reshape" this area by septotomy. Septotomy procedure: Sequential incisions were performed using argon plasma coagulation (APC) with 2.5 flow and 50 W (WEM, SP, Brazil) over the septum in order to allow communication between the perigastric cavity (leak site) and the gastric lumen. The principles below must be followed: (1) Scope position: the endoscopist's left hand holds the control body of the gastroscope while the right hand holds the insertion tube; the APC catheter has no need to be fixed. This avoids movements and unprogrammed maneuvers. (2) Before cutting, the septum is placed in the six o'clock position on the endoscopic view, by rotating the gastroscope. (3) The septum is sectioned until the bottom of the perigastric cavity (leak site). (4) That section is made towards the staple line. (5) Just after the septotomy, a Savory-Gilliard guidewire (Cook Medical, Indiana, USA) through the scope must be inserted until the duodenum, followed by 30-mm balloon (Rigiflex®, Boston Scientific, MA, USA) insertion. The balloon catheter must be firmly held during gradual inflation (maximum 10 psi) to avoid slippage and laceration. This allows increasing the gastric lumen. (6) Septotomy by electrocautery with a needle knife (Boston Scientific, MA, USA) can be made when an intensive fibrotic septum is present; bleeding is rare in this case. In this case, the endoclip previously used was removed from the septum with forceps to avoid heat transmission. Small staples visualized in the fistula orifice were not completely removed due to technical difficulties and friable tissue. Two sessions were performed in 15 days, resulting in leak closure. The patient was submitted to radiological control 1 week after the second session, which revealed fistula healing, without gastric stenosis. The nasoduodenal feeding tube remained for 7 days, when the patient started oral diet. This patient was followed for 18 months without recurrence. Septotomy and balloon dilation were initially performed on a difficult-to-treat chronic fistula after gastric bypass and named before as stricturotomy (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007). This procedure allows internal drainage of the fistula and deviates oral intake to the pouch. In addition, achalasia balloon dilation treats strictures and axis deviation of the gastric chamber, promoting reduction of the intragastric pressure. Septotomy and balloon dilation are technically feasible and might be useful in selected cases for closure of chronic leaks after LSG.

  18. Endoscopy in screening for digestive cancer

    PubMed Central

    Lambert, René

    2012-01-01

    The aim of this study is to describe the role of endoscopy in detection and treatment of neoplastic lesions of the digestive mucosa in asymptomatic persons. Esophageal squamous cell cancer occurs in relation to nutritional deficiency and alcohol or tobacco consumption. Esophageal adenocarcinoma develops in Barrett’s esophagus, and stomach cancer in chronic gastric atrophy with Helicobacter pylori infection. Colorectal cancer is favoured by a high intake in calories, excess weight, low physical activity. In opportunistic or individual screening endoscopy is the primary detection procedure offered to an asymptomatic individual. In organized or mass screening proposed by National Health Authorities to a population, endoscopy is performed only in persons found positive to a filter selection test. The indications of primary upper gastrointestinal endoscopy and colonoscopy in opportunistic screening are increasingly developing over the world. Organized screening trials are proposed in some regions of China at high risk for esophageal cancer; the selection test is cytology of a balloon or sponge scrapping; they are proposed in Japan for stomach cancer with photofluorography as a selection test; and in Europe, America and Japan; for colorectal cancer with the fecal occult blood test as a selection test. Organized screening trials in a country require an evaluation: the benefit of the intervention assessed by its impact on incidence and on the 5 year survival for the concerned tumor site; in addition a number of bias interfering with the evaluation have to be controlled. Drawbacks of screening are in the morbidity of the diagnostic and treatment procedures and in overdetection of none clinically relevant lesions. The strategy of endoscopic screening applies to early cancer and to benign adenomatous precursors of adenocarcinoma. Diagnostic endoscopy is conducted in 2 steps: at first detection of an abnormal area through changes in relief, in color or in the course of superficial capillaries; then characterization of the morphology of the lesion according to the Paris classification and prediction of the risk of malignancy and depth of invasion, with the help of chromoscopy, magnification and image processing with neutrophil bactericidal index or FICE. Then treatment decision offers 3 options according to histologic prediction: abstention, endoscopic resection, surgery. The rigorous quality control of endoscopy will reduce the miss rate of lesions and the occurrence of interval cancer. PMID:23293721

  19. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer to simultaneously obtain spatial and spectral information on science targets; the long baseline provides subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

  20. Application of self-expandable metal stents for ureteroileal anastomotic strictures: long-term results.

    PubMed

    Liatsikos, Evangelos N; Kagadis, George C; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Papathanassiou, Zafiria; Constantinides, Constantinos; Perimenis, Petros; Nikiforidis, George C; Stolzenburg, Jens-Uwe; Siablis, Dimitrios

    2007-07-01

    We report our long-term experience with the management of benign ureteroileal anastomotic strictures using self-expandable metal stents. A total of 16 male and 2 female patients with a mean+/-SD age of 72+/-7 years (range 66 to 78) with benign fibrotic strictures at the site of ureteroileal anastomosis underwent implantation of self-expandable metal stents with a nominal diameter of 6 to 8 mm. A total of 24 ureteroileal conduits were treated. The external nephrostomy tubes were removed after fluoroscopic validation of ureteral patency. Patients were followed with blood biochemistry, ultrasonography, urography and/or virtual endoscopy. Retrograde external-internal catheter insertion through the cutaneous stoma was performed in cases of recalcitrant stricture. The technical success rate of ureteroileal stricture crossing and stenting was 100% (24 of 24 cases). Mean followup was 21 months (range 7 to 50). The clinical success rate during the immediate post-stenting period was 70.8% (17 of 24 cases). The 1 and 4-year primary patency rates were 37.8% and 22.7%, respectively. Secondary interventions included repeat balloon dilation in 15 ureters, of which 8 also underwent subsequent coaxial stent placement. The 1 and 4-year secondary patency rates were 64.8% and 56.7%, respectively. Except in 2 patients who died external-internal Double-J catheters continued to be inserted retrograde in 6 ureteroileal conduits. They are periodically exchanged to prevent mucous inspissation and stent encrustation. Metal stents served as the definitive treatment for stricture in more than half of the cases, whereas in the remainder the stents allowed the uncomplicated and regular exchange of Double-J catheters in retrograde fashion. This combined, less invasive treatment for ureteroileal anastomotic strictures may help patients avoid surgical revision and preserve quality of life.

  1. Balloon dilatation in esophageal strictures in epidermolysis bullosa and the role of anesthesia.

    PubMed

    Gollu, Gulnur; Ergun, Ergun; Ates, Ufuk; Can, Ozlem S; Dindar, Huseyin

    2017-02-01

    Esophageal involvement, which causes stricture, is a complication in epidermolysis bullosa. This causes dysphagia and malnutrition and leads to deterioration of skin lesions in these patients. The charts of 11 patients with epidermolysis bullosa and esophageal stricture who were included into dilatation program between 2003 and 2015 were retrospectively reviewed. Seven of the patients were female and four were male. The median age was 14 (2-32) years. The mean body weight of patients was 27.8 (9-51) kg. The location and number of strictured parts of the esophagus were previously evaluated with upper gastrointestinal contrast study and after that flexible endoscopy was used for dilatation. Eight patients had middle esophageal, three patients had proximal esophageal and one of them had both proximal and middle esophageal strictures. The strictures were dilated 56 times in total (mean 5 times). One patient underwent gastrostomy and was medically followed-up after a perforation occurrence during the dilatation procedure. In a 32-year-old female patient, colon interposition was performed after four dilatations since optimal nutritional and developmental status could not be achieved. The dilatation program of nine patients is still in progress. Seven of them can easily swallow solid food but two of them have some difficulties in swallowing between dilatations. One patient rejected the program and quitted, while one patient refused colon interposition and died because of complications related to amyloidosis during the dilatation program. After resolution of the swallowing problem, skin lesions were observed to heal quickly. Epidermolysis bullosa is a rare cause of dysphagia. Esophageal balloon dilatation with flexible endoscopy is a safe and efficient method in patients with this condition. © 2016 International Society for Diseases of the Esophagus.

  2. Idiopathic small bowel diaphragm disease identified by laparoscopic-assisted double-balloon enteroscopy in a child: an integrated successful definitive therapeutic method.

    PubMed

    Soccorso, Giampiero; Sarkhy, Ahmed; Lindley, Richard M; Marven, Sean S; Thomson, Mike

    2012-08-01

    In adults, small bowel diaphragm disease is a rare complication of small bowel enteropathy secondary to the use of nonsteroidal antiinflammatory drugs. The main clinical manifestations are gastrointestinal bleeding and subacute obstruction, and management can be challenging. We present a case of a 5-year-old girl with small bowel diaphragm disease. To our knowledge, this is the first idiopathic case (no history of nonsteroidal antiinflammatory drug use) in the pediatric age group. This report describes an integrated successful definitive therapeutic method of double-balloon enteroscopy and minimal invasive bowel surgery for small bowel pathology. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Identifying DNA Methylation Biomarkers for Non-Endoscopic Detection of Barrett’s Esophagus

    PubMed Central

    Moinova, Helen R.; LaFramboise, Thomas; Lutterbaugh, James D.; Chandar, Apoorva Krishna; Dumot, John; Faulx, Ashley; Brock, Wendy; De la Cruz Cabrera, Omar; Guda, Kishore; Barnholtz-Sloan, Jill S.; Iyer, Prasad G.; Canto, Marcia I.; Wang, Jean S.; Shaheen, Nicholas J.; Thota, Prashanti N.; Willis, Joseph E.; Chak, Amitabh; Markowitz, Sanford D.

    2018-01-01

    We report a biomarker-based non-endoscopic method for detecting Barrett’s esophagus (BE), based on detecting methylated DNAs retrieved via a swallowable balloon-based esophageal sampling device. BE is the precursor of, and a major recognized risk factor for, developing esophageal adenocarcinoma (EAC). Endoscopy, the current standard for BE detection, is not cost-effective for population screening. We performed genome-wide screening to ascertain regions targeted for recurrent aberrant cytosine methylation in BE, identifying high-frequency methylation within the CCNA1 locus. We tested CCNA1 DNA methylation as a BE biomarker in cytology brushings of the distal esophagus from 173 individuals with or without BE. CCNA1 DNA methylation demonstrated an area under the curve (AUC)=0.95 for discriminating BE-related metaplasia and neoplasia cases versus normal individuals, performing identically to methylation of VIM DNA, an established BE biomarker. When combined, the resulting two biomarker panel was 95% sensitive and 91% specific. These results were replicated in an independent validation cohort of 149 individuals, who were assayed using the same cutoff values for test positivity established in the training population. To progress toward non-endoscopic esophageal screening, we engineered a well-tolerated, swallowable, encapsulated balloon device able to selectively sample the distal esophagus within 5 minutes. In balloon samples from 86 individuals, tests of CCNA1 plus VIM DNA methylation detected BE metaplasia with 90.3% sensitivity and 91.7% specificity. Combining the balloon sampling device with molecular assays of CCNA1 plus VIM DNA methylation enables an efficient, well-tolerated, sensitive, and specific method of screening at-risk populations for BE. PMID:29343623

  4. Use of the Ascent balloon for a 2-in-1 remodeling technique: feasibility and initial experience: case report.

    PubMed

    Clarençon, Frédéric; Pérot, Guillaume; Biondi, Alessandra; Di Maria, Federico; Szatmary, Zoltan; Chiras, Jacques; Sourour, Nader

    2012-03-01

    To present the feasibility of using the Ascent balloon, a new double-lumen remodeling balloon, for a new 2-in-1 technique allowing coiling through the lumen of the balloon without the use of an additional coiling microcatheter. Remodeling technique had enlarged the indications for endovascular treatment of intracranial aneurysm. Nevertheless, one of the limitations of this technique is that it requires using 2 devices in the same parent artery. A 55-year-old woman presented with a 7.7 × 4.5-mm incidental anterior communicating artery aneurysm. Only 1 A1 segment (left side) was patent on the cerebral angiogram. A 6F Fargo Max guiding catheter was positioned in the left petrous internal carotid artery. The Ascent balloon was placed in front of the neck of the aneurysm after navigation on a Traxcess 0.014-in guidewire. Coiling of the aneurysm sac was performed via 1 lumen of the device under iterative inflations of the balloon through the second lumen. This new 2-in-1 technique using a sole remodeling balloon without an additional coiling microcatheter is very promising, especially in cases of a small-caliber parent artery.

  5. Design and Status of the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII): An Interferometer at the Edge of Space

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen A.; Barclay, Richard B.; Barry, R. K.; Benford, D. J.; Calhoun, P. C.; Fixsen, D. J.; Gorman, E. T.; Jackson, M. L.; Jhabvala, C. A.; Leisawitz, D. T.; hide

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infraredinterferometer designed to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer tosimultaneously obtain spatial and spectral information on science targets; the long baseline permits subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

  6. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen A.

    2010-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to far-infrared emission arises. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII), an eight-meter Michelson interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks in young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers.

  7. BETTII: The Balloon Experimental Twin Telescope for Infrared Interferometry

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen

    2011-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding the universe. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to far-infrared emission arises. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII),8oeight-meter Michelson interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks io young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers.

  8. Arterioureteral Fistula: Treatment of a Hemorrhagic Shock with Massive Hematuria by Placing a Balloon Catheter.

    PubMed

    Merzeau, Nicolas; Riquet, Hervé; Nicolacopoulos, Ioannis; Alame, Abbas; Larré, Stéphane

    2017-01-01

    Arterioureteral fistulas (AUF) are serious diseases with increasing incidence. This case report relates the management of AUF in a patient with a history of abdominal oncological surgery, pelvic radiotherapy, and a double J stent in place. The fistula was discovered during a hemorrhagic shock with massive hematuria. The bleeding was controlled by a balloon catheter which led to endovascular treatment consisting of a covered stent.

  9. Arterioureteral Fistula: Treatment of a Hemorrhagic Shock with Massive Hematuria by Placing a Balloon Catheter

    PubMed Central

    Riquet, Hervé; Nicolacopoulos, Ioannis; Alame, Abbas

    2017-01-01

    Arterioureteral fistulas (AUF) are serious diseases with increasing incidence. This case report relates the management of AUF in a patient with a history of abdominal oncological surgery, pelvic radiotherapy, and a double J stent in place. The fistula was discovered during a hemorrhagic shock with massive hematuria. The bleeding was controlled by a balloon catheter which led to endovascular treatment consisting of a covered stent. PMID:28465857

  10. [Primary esophageal motility disorders; especially about esophageal achalasia].

    PubMed

    Miyazaki, Tatsuya; Sohda, Makoto; Sakai, Makoto; Tanaka, Naritaka; Suzuki, Shigemasa; Yokobori, Takehiko; Inose, Takanori; Nakajima, Masanobu; Fukuchi, Minoru; Kato, Hiroyuki; Kusano, Motoyasu; Kuwano, Hiroyuki

    2011-07-01

    Esophageal motility disorders are classified primary and secondary, and primary esophageal motility disorders are classified esophageal achalasia and other diseases by manometry. An esophageal emptying disorder associated with insufficient relaxation of the lower esophageal sphincter (LES) and elimination of peristaltic waves on the esophageal body is the major abnormality of achalasia. Esophagogram, endoscopy, and manometry are used for diagnosis. As pharmacological therapy, administration of a calcium channel blocker or nitrate is useful. The pharmacological therapy is not recommended as long-term basic therapy but as a temporary treatment. At 1st, the balloon dilation method is chosen in treatment of achalasia Surgical treatment is indicated in the following cases: (1) Patients uneffected by balloon dilation, (2) Flask type with grade II to III dilation, and sigmoid type, (3) the gradual progression to the pathophysiological stage, (4) young patients, (5) complicated with esophageal cancer. Laparoscopic Heller-Dor procedure is the most popular surgical procedure, recently. It is somewhat difficult to perform surgical treatment for this functional disease. We should select the most suitable individualized treatment with efficient comprehension of the pathophysiological situation.

  11. Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Kiyohito, E-mail: rad105@poh.osaka-med.ac.jp; Yamamoto, Kazuhiro, E-mail: rad043@poh.osaka-med.ac.jp; Nakai, Go, E-mail: rad091@poh.osaka-med.ac.jp

    2016-06-15

    PurposeApproximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College regimen. This study aimed to show the quantitative difference in hemodynamics of the bladder arteries using syngo iFlow (Siemens Healthcare, Erlangen, Germany), which provides an automatic tool for quantitative blood flow analysis between double BOAI (D-BOAI) and conventional single BOAI (S-BOAI).Materials and MethodsFifty patients were included. The catheters were introduced into both posterior trunks of the internal iliac arteries via contralateral femoral artery access.more » A side hole between the distal and proximal balloons was placed at the origin of each bladder artery to allow clear visualization of angiographic flow of the injected agent into the urinary bladder. Digital subtraction angiography was used during analysis with the syngo iFlow to evaluate the hemodynamics of the contrast medium in the pelvic arteries during BOAI. The comparative change in the amount of contrast medium in the bladder arteries between D-BOAI and S-BOAI was assessed using syngo iFlow.ResultsOne-hundred pelvic sides were analyzed. The amount of contrast medium in the bladder arteries using D-BOAI was more than twice that using S-BOAI (right, 3.03-fold; left, 2.81-fold).ConclusionThe amount of contrast medium in the bladder arteries using D-BOAI was higher than that using conventional S-BOAI. This may increase the anticancer drug concentration in the affected bladder, leading to a good clinical response.« less

  12. Treatment of benign esophageal stricture by Eder-Puestow or balloon dilators: a comparison between randomized and prospective nonrandomized trials.

    PubMed

    Yamamoto, H; Hughes, R W; Schroeder, K W; Viggiano, T R; DiMagno, E P

    1992-03-01

    To determine whether the natural history of strictures is affected by the type of dilator used to treat newly diagnosed peptic strictures, we designed a prospective randomized trial to compare the results after Eder-Puestow or Medi-Tech balloon dilation. We entered 31 patients into the trial. We also prospectively followed up all 92 nonrandomized patients who underwent their first dilation for a benign stricture during the same period as the prospective randomized trial. The nonrandomized patients also underwent dilation with either the Eder-Puestow or the balloon technique at the discretion of the gastroenterologist performing the endoscopy. We found no statistically significant differences in the immediate or long-term results of the two methods among the randomized, nonrandomized, and overall combined groups. All but 1 of the 123 patients had immediate relief of dysphagia. Within each group of patients, the probability of remaining free of dysphagia 1 year after the initial dilation was approximately 20%, and the probability of not requiring a second dilation was approximately 65% with either technique. Major (esophageal rupture) and minor (bleeding or chest pain) complications occurred in 1% and 5% of the patients and 0.4% and 3% of the total dilation procedures, respectively. The esophageal rupture and four of six minor complications occurred after repeated dilations. Five of the six minor complications occurred with use of the Eder-Puestow dilators. We conclude that Eder-Puestow and balloon dilations of benign esophageal strictures are associated with similar outcomes, but repeated dilations and the Eder-Puestow technique may be associated with an increased risk of complications.

  13. Pancreatic and Gastric Heterotopia with Associated Submucosal Lipoma Presenting as a 7-cm Obstructive Tumor of the Ileum: Resection with Double Balloon Enteroscopy.

    PubMed

    Jiang, Kun; Stephen, F Otis; Jeong, Daniel; Pimiento, Jose M

    2015-01-01

    Pancreatic and gastric heterotopias are rare clinical entities which have been identified throughout the entire length of the gastrointestinal tract. Combined gastric and pancreatic heterotopias, although unusual, have been described in the duodenum and jejunum, and in other structures, including Meckel's diverticulum and the ampulla of Vater. We report a novel case of pancreatic and gastric heterotopia with an associated submucosal lipoma in a 38-year-old female with a recent history of rectal cancer and chronic crampy abdominal pain. On computed tomography, a 7-cm luminal polypoid mass extending into the distal ileum was discovered. The mass was successfully resected using retrograde double balloon enteroscopy. We believe this is the first report of all three histological entities co-existing in an obstructive ileal lesion in an adult. It highlights endoscopic resection trough double enteroscopy as a safe alternative to more invasive surgical approaches for this type of lesion.

  14. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration

    PubMed Central

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-01-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment. PMID:27956966

  15. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    PubMed

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  16. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    PubMed

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  17. Advanced endoscopic imaging to improve adenoma detection

    PubMed Central

    Neumann, Helmut; Nägel, Andreas; Buda, Andrea

    2015-01-01

    Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092

  18. The sensitivity of radiography of the postoperative stomach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ott, D.J.; Munitz, H.A.; Gelfand, D.W.

    1982-09-01

    The results of radiology and endoscopy were compared in 140 patients who had undergone gastric surgery for ulcer disease. Of 74 patients who were examined with single-contrast radiography, 37 had abnormalities that were demonstrated endoscopically. The radiographic sensitivities in these patients were: gastritis 2/22 (9%); ulcer 3/5 (60%); obstruction 8/8 (100%); and miscellaneous abnormalities 2/2 (100%). The predictive accuracy of a diagnois of ulcer was 38%. Of the 66 patients who were examined with double-contrast radiography, 33 abnormalities were found with endoscopy. The radiographic sensitivities were: gastritis 3/13 (23%); ulcer 7/10 (70%); obstruction 4/4 (100%); and miscellaneous abnormalities 6/6 (100%).more » The predictive accuracy of a diagnosis of ulcer was 44%. Radiology appears to be unreliable in diagnosing gastritis and recurrent ulceration in the post-operation stomach. The double-contrast technique does not offer significant improvement over the single-contrast method in evaluating these postoperative problems.« less

  19. Comparison of double-balloon and single-balloon enteroscope for therapeutic endoscopic retrograde cholangiography after Roux-en-Y small bowel surgery.

    PubMed

    De Koning, Michael; Moreels, Tom G

    2016-08-22

    Roux-en-Y reconstructive surgery excludes the biliopancreatic system from conventional endoscopic access. Balloon-assisted enteroscopy allows therapeutic endoscopic retrograde cholangiopancreatography (ERCP) in these patients, avoiding rescue surgery. The objective of the current study is to compare success and complication rate of double-balloon (DBE) and single-balloon enteroscope (SBE) to perform ERCP in Roux-en-Y patients. Seventy three Roux-en-Y patients with suspected biliary tract pathology underwent balloon-assisted enteroscopy in a tertiary-care center. Retrospective analysis of 95 consecutive therapeutic ERCP procedures was performed to define and compare success and complication rate of DBE and SBE. Male-female ratio was 28/45 with a mean age of 58 ± 2 years. 30 (32 %) procedures were performed with DBE and 65 (68 %) with SBE. Overall ERCP success rate was 73 % for DBE and 75 % for SBE (P = 0.831). Failure was due to inability to reach or cannulate the intact papilla or bilioenteric anastomosis. Success rate was significantly higher when performed at the bilioenteric anastomosis (80 % success in 56 procedures) or at the intact papilla in short-limb Roux-en-Y (80 % in 15 procedures) as compared to the intact papilla in long-limb (58 % in 24 procedures; P = 0.040). Adverse event rates were 10 % (DBE) and 8 % (SBE) (P = 0.707) and mostly dealt with conservatively. ERCP after Roux-en-Y altered small bowel anatomy is feasible and safe using both DBE and SBE. Both techniques are equally competent with high success rates and acceptable adverse events rates. ERCP at the level of the intact papilla in long limb Roux-en-Y is less successful as compared to short-limb or bilioenteric anastomosis.

  20. Primary obstructive megaureter: the role of high pressure balloon dilation.

    PubMed

    Romero, Rosa M; Angulo, Jose Maria; Parente, Alberto; Rivas, Susana; Tardáguila, Ana Rosa

    2014-05-01

    There is a growing interest in minimally invasive treatment of primary obstructive megaureter (POM) in children. The absence of long-term follow-up data, however, makes it difficult to establish the indication for an endoscopic approach. The aim of our study is to determine the long-term efficacy of endourologic high-pressure balloon dilation of the vesicoureteral junction (VUJ) in children with POM that necessitates surgical treatment. We retrospectively reviewed the clinical records from children with POM who were treated with endourologic high-pressure balloon dilation of the VUJ from March 2003 to April 2010. To determine the long-term, a cohort study was conducted in November 2011. Endourologic dilation of the VUJ was performed with a semicompliant high-pressure balloon (2.7 FG) with a minimum balloon size of 3 mm, followed by placement of a Double-J stent. We have treated 29 (32 renal units, left [n=16], right [n=10] and bilateral [n=3]) children with a diagnosis of POM within this period. The median age at the time of the endourologic treatment was 4.04 months (range 1.6-39 months). In three cases, an open ureteral reimplantation was needed, in two cases because of intraoperative technical failure and postoperative Double-J stent migration in one patient. The 26 children (29 renal units) who had a successful endourologic dilation of the VUJ were followed with ultrasonography and MAG-3-Lasix (furosemide) studies that showed a progressive improvement of both the ureterohydronephrosis and drainage in the first 18 months in 20 patients (23 renal units) (69%). In two patients who were treated with a 3 mm balloon, a further dilation was needed, with an excellent outcome. The cohort study (at a median follow-up of 47 months) showed that in all patients who had a good outcome at the 18-month follow-up after endourologic balloon dilation remained asymptomatic with resolution of ureterohydronephrosis on the US and good drainage on the renogram, in the children with some persistent hydronephrosis. Our study shows that children with POM who were treated with high-pressure ballon dilation of the VUJ who have satisfactory appearance at 18 months maintain these results over time.

  1. Telemetry Options for LDB Payloads

    NASA Technical Reports Server (NTRS)

    Stilwell, Bryan D.; Field, Christopher J.

    2016-01-01

    The Columbia Scientific Balloon Facility provides Telemetry and Command systems necessary for balloon operations and science support. There are various Line-Of-Sight (LOS) and Over-The-Horizon (OTH) systems and interfaces that provide communications to and from a science payload. This presentation will discuss the current data throughput options available and future capabilities that may be incorporated in the LDB Support Instrumentation Package (SIP) such as doubling the TDRSS data rate. We will also explore some new technologies that could potentially expand the data throughput of OTH communications.

  2. Endocytoscopic findings of lymphomas of the stomach.

    PubMed

    Isomoto, Hajime; Matsushima, Kayoko; Hayashi, Tomayoshi; Imaizumi, Yoshitaka; Shiota, Junya; Ishii, Hiroyuki; Minami, Hitomi; Ohnita, Ken; Takeshima, Fuminao; Shikuwa, Saburo; Miyazaki, Yasushi; Nakao, Kazuhiko

    2013-12-26

    The gastric lesions of various lymphomas were observed at the cellular level using endocytoscopy. Endocytoscopy and magnifying endoscopy with narrow band imaging (NBI) were performed in 17 patients with lymphomas of the stomach. The lesions consisted of 7 with low-grade mucosa-associated lymphoid tissue (MALT), 5 with gastric involvement by adult T-cell leukemia/lymphoma (ATLL), 4 with diffuse large B-cell lymphoma (DLBCL), and 1 with peripheral T-cell lymphoma. On conventional endoscopy, 9 were classified as having superficial spreading type, 7 were mass-forming type, and 1 was diffuse infiltrating type. Anti-H. pylori treatment was given in the 7 MALT lymphoma cases. NBI magnification endoscopy invariably showed dilatation or ballooning and destruction of gastric pits and elongation and distortion in microvessels. Endocytoscopy showed mucosal aggregation of interstitial cellular elements in almost all gastric lymphoma cases. The nuclear diversity in size and configuration was exclusively seen in gastric lymphomas other than MALT lymphoma, whereas the nuclei of MALT lymphoma cells were regular and small to moderate in size. Inter-glandular infiltration by lymphomatous cell elements was frequently observed in MALT lymphoma and DLBCL, but it was uncommon in peripheral gastric T-cell malignancies. Endocytoscopy could identify the disease-specific histology, the lymphoepithelial origin, as inter-glandular infiltration of cellular components in MALT lymphoma and the possibly related DLBCL cases. Complete regression (CR) was observed in 2 of the 7 MALT lymphoma patients. In the 2 patients with CR who underwent repeat endocytoscopy, the ultra-high magnification abnormalities returned to normal, while they were unchanged in those without tumor regression. On endocytoscopy, intra-glandular aggregation of cellular components was invariably identified in lymphomas of the stomach. Nuclear regularity in size and configuration may indicate the cytological grade, differentiating the indolent low-grade from aggressive lymphoproliferative diseases. The inter-glandular infiltration seen on endocytoscopy can indicate the lymphoepithelial lesions seen in MALT lymphoma and related DLBCL. Endocytoscopy would be applicable for virtual histopathological diagnosis of different lymphoproliferative disorders and their clinical assessment during ongoing endoscopy.

  3. Balloon dilation of sinus ostia in the Department of Defense: Diagnoses, actual indications, and outcomes.

    PubMed

    Laury, Adrienne M; Bowe, Sarah N; Stramiello, Joshua; McMains, Kevin C

    2017-03-01

    To determine the primary diagnoses for which balloon catheter dilation (BCD) of sinus ostia is being employed in a profit-blind health care system, the Department of Defense. Retrospective chart review. From January 1, 2011 to December 31, 2013, 319 consecutive patient charts were reviewed for International Classification of Diseases, Ninth Edition (ICD-9) diagnoses, presence of chronic rhinosinusitis (CRS) defined by the European Position Paper on Rhinosinusitis and Nasal Polyps (EPOS), preoperative Lund-Mackay scores, nasal endoscopy findings, sinuses dilated, postoperative outcomes, and complications. Of the 319 patients identified, 217 had sufficient documentation to be included. A CRS ICD-9 code was applied in 182 of 217 (83.9%) and recurrent acute rhinosinusitis in 12 of 217 (5.6%). Only 50.5% of CRS patient charts met criteria using EPOS guidelines. In contrast, 39.6% met the ICD-9 criteria for atypical facial pain. Patients with Lund-Mackay scores ≤ 4 were reviewed for number of sinuses dilated. Eighty-eight of 123 patients (71.5%) had sinuses dilated that were free from opacification/mucosal edema on preoperative imaging. Balloon dilation of sinus ostia has an expanding role in treating sinus disease. In the studied population, BCD is often utilized for alternate indications for which there is currently no evidence of efficacy. Future studies are needed to evaluate the efficacy of this technology in treating these alternate indications. 4. Laryngoscope, 127:544-549, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  4. [The usefullness of percutaneous transluminal balloon angioplasty in the management of budd-Chiari syndrome].

    PubMed

    Kim, Se Hwan; Yu, Kyung Sool; Baek, Seung Min; Lee, Seung Yup; Kim, Hyun Su; Tak, Won Young; Kweon, Young Oh; Kim, Sung Kook; Choi, Yong Hwan; Chung, Joon Mo

    2002-06-01

    Membranous obstruction is the most common cause of Budd-Chiari syndrome in Orientals. Recently, percutaneous transluminal balloon angioplasty (PTBA) has been successfully applied as a treatment of membranous obstruction. We evaluated etiologies and clinical manifestations in our cases and the usefulness of PTBA. Twelve cases of Budd-Chiari syndrome were analyzed. 50.3 years was the average age of the cases (ranging from 37 to 67 years). Major symptoms or signs were superficial collateral vessels on the chest or the abdomen in 6 cases, ascites in 3, abdominal pain in 4, hepatomegaly in 4, splenomegaly in 3, melena or hematemesis in 2, and leg edema in 2. Upper gastrointestinal endoscopy showed esophageal varices in 6 cases and two of these 6 cases had gastric varices. Of 8 cases with liver cirrhosis, 4 were classified as Child-Pugh class A and 4 as B. Four patients with cirrhosis had concurrent hepatocellular carcinoma including 1 patient who was HBs Ag positive. Etiologies were membranous obstruction in 11 cases and protein C deficiency in 1 case. The main site of obstruction was IVC in 8 and hepatic vein in 4. PTBA was successfully performed in 8 cases of membranous obstruction. During the mean follow-up period of 27.6 months (12-40 months), there were no reobstructions except in 2 cases. The most common cause of Budd-Chiari syndrome in our cases was membranous obstruction of IVC. Percutaneous transluminal balloon angioplasty is a very useful treatment method.

  5. Peutz-Jeghers syndrome: Diagnostic and therapeutic approach

    PubMed Central

    Kopacova, Marcela; Tacheci, Ilja; Rejchrt, Stanislav; Bures, Jan

    2009-01-01

    Peutz-Jeghers syndrome (PJS) is an inherited, autosomal dominant disorder distinguished by hamartomatous polyps in the gastrointestinal tract and pigmented mucocutaneous lesions. Prevalence of PJS is estimated from 1 in 8300 to 1 in 280 000 individuals. PJS predisposes sufferers to various malignancies (gastrointestinal, pancreatic, lung, breast, uterine, ovarian and testicular tumors). Bleeding, obstruction and intussusception are common complications in patients with PJS. Double balloon enteroscopy (DBE) allows examination and treatment of the small bowel. Polypectomy using DBE may obviate the need for repeated urgent operations and small bowel resection that leads to short bowel syndrome. Prophylaxis and polypectomy of the entire small bowel is the gold standard in PJS patients. Intraoperative enteroscopy (IOE) was the only possibility for endoscopic treatment of patients with PJS before the DBE era. Both DBE and IOE facilitate exploration and treatment of the small intestine. DBE is less invasive and more convenient for the patient. Both procedures are generally safe and useful. An overall recommendation for PJS patients includes not only gastrointestinal multiple polyp resolution, but also regular lifelong cancer screening (colonoscopy, upper endoscopy, computed tomography, magnetic resonance imaging or ultrasound of the pancreas, chest X-ray, mammography and pelvic examination with ultrasound in women, and testicular examination in men). Although the incidence of PJS is low, it is important for clinicians to recognize these disorders to prevent morbidity and mortality in these patients, and to perform presymptomatic testing in the first-degree relatives of PJS patients. PMID:19916169

  6. Immediate detection of endoscopic retrograde cholangiopancreatography-related periampullary perforation: Fluoroscopy or endoscopy?

    PubMed Central

    Motomura, Yasuaki; Akahoshi, Kazuya; Gibo, Junya; Kanayama, Kenji; Fukuda, Shinichiro; Hamada, Shouhei; Otsuka, Yoshihiro; Kubokawa, Masaru; Kajiyama, Kiyoshi; Nakamura, Kazuhiko

    2014-01-01

    AIM: To investigate the causes and intraoperative detection of endoscopic retrograde cholangiopancreatography (ERCP)-related perforations to support immediate or early diagnosis. METHODS: Consecutive patients who underwent ERCP procedures at our hospital between January 2008 and June 2013 were retrospectively enrolled in the study (n = 2674). All procedures had been carried out using digital fluoroscopic assistance with the patient under conscious sedation. For patients showing alterations in the gastrointestinal anatomy, a short-type double balloon enteroscope had been applied. Cases of perforation had been identified by the presence of air in or leakage of contrast medium into the retroperitoneal space, or upon endoscopic detection of an abdominal cavity related to the perforated lumen. For patients with ERCP-related perforations, the data on medical history, endoscopic findings, radiologic findings, diagnostic methods, management, and clinical outcomes were used for descriptive analysis. RESULTS: Of the 2674 ERCP procedures performed during the 71-mo study period, only six (0.22%) resulted in perforations (male/female, 2/4; median age: 84 years; age range: 57-97 years). The cases included an endoscope-related duodenal perforation, two periampullary perforations related to endoscopic sphincterotomy, two periampullary perforations related to endoscopic papillary balloon dilation, and a periampullary or bile duct perforation secondary to endoscopic instrument trauma. No cases of guidewire-related perforation occurred. The video endoscope system employed in all procedures was only able to immediately detect the endoscope-related perforation; the other five perforation cases were all detected by subsequent digital fluoroscope applied intraoperatively (at a median post-ERCP intervention time of 15 min). Three out of the six total perforation cases, including the single case of endoscope-related duodenal injury, were surgically treated; the remaining three cases were treated with conservative management, including trans-arterial embolization to control the bleeding in one of the cases. All patients recovered without further incident. CONCLUSION: ERCP-related perforations may be difficult to diagnose by video endoscope and digital fluoroscope detection of retroperitoneal free air or contrast medium leakage can facilitate diagnosis. PMID:25400465

  7. Onyx embolization using dual-lumen balloon catheter: initial experience and technical note.

    PubMed

    Paramasivam, Srinivasan; Niimi, Yasunari; Fifi, Johanna; Berenstein, Alejandro

    2013-10-01

    Onyx as an embolization agent for the management of vascular malformation is well established. We report our initial experience with dimethyl-sulphoxide (DMSO) compatible double lumen balloon catheters used for Onyx embolization. Between December 2011 and March 2013, we treated 22 patients aged between 1.5 to 70years with two types of DMSO compatible dual-lumen balloon catheters (Scepter C and Ascent) to treat dural arteriovenous fistulas, brain arteriovenous malformation (AVM) with dural feeders, mandibular, facial, lingual, vertebral and paravertebral AVMs. The catheter has good navigability, compliant balloon on inflation formed a "plug" that has more resistance than Onyx plug enhancing better penetration. During injection, the balloon remained stable without spontaneous deflation or rupture and withstood the pressure build-up well. The retrieval of the catheter in most cases took less than a minute (19/28) while in five, it was less than five minutes and in the remaining four, it was longer that includes a trapped catheter on prolonged attempted retrieval resulted in an epidural hematoma, requiring emergent surgical evacuation. The fluoroscopy time is reduced, as we do not form a proximal onyx plug, the injection time is shorter along with easy and instantaneous removal of the catheter after balloon deflation in most cases. Dual-lumen balloon catheter Onyx embolization is a safe and effective technique. Currently, an important tool to circumvent some of the shortcomings associated with Onyx embolization. The catheter has good navigability, the balloon has stability, tolerance, enhances penetrability. It is easy to retrieve the microcatheter. With the experience gained, and with more compliant balloon catheters available, this technique can be applied to cerebral vessels in near future. Copyright © 2013. Published by Elsevier Masson SAS.

  8. Bipolar versus balloon endometrial ablation in the office: a randomized controlled trial.

    PubMed

    Penninx, Josien P M; Herman, Malou C; Kruitwagen, Roy F P M; Ter Haar, Annette J F; Mol, Ben W; Bongers, Marlies Y

    2016-01-01

    To compare the effectiveness of bipolar radiofrequency (Novasure®) ablation and balloon endometrial ablation (Thermablate®). We performed a multi-center double blind, randomized controlled trial in three hospitals in The Netherlands. Women with heavy menstrual bleeding were randomly allocated to bipolar or balloon endometrial ablation, performed in the office, using a paracervical block. The primary outcome was amenorrhea. Secondary outcome measures were pain, satisfaction, quality of life and reintervention. 104 women were randomized into the bipolar (52) and balloon (52) groups. After 12 months amenorrhea rates were 56% (29/52) in the bipolar group and 23% (12/52) in the balloon group (relative risk (RR) 0.6, 95% confidence interval (CI) 0.4-0.8). The mean visual analog pain score of the total procedure was 7.1 in the bipolar group and 7.4 in the balloon group (P<.577). 87% (45/52) of the patients in the bipolar group were satisfied with the result of the treatment versus 69% (36/52) in the balloon group (RR 0.44, 95% CI 0.2-0.97). The reintervention rates were 5/52 (10%) in the bipolar group and 6/52 (12%) in the balloon group (RR 1.02, 95% CI 0.9-1.2). Quality of life (Shaw score) improved over time (P<.001) and was significantly higher in the bipolar group at 12 months follow-up (P=.025). In the treatment of heavy menstrual bleeding, bipolar radiofrequency endometrial ablation is superior to balloon endometrial ablation as an office procedure in amenorrhea rate, patient satisfaction and quality of life. Copyright © 2015. Published by Elsevier Ireland Ltd.

  9. Science Results From The ARCADE Open-Aperture Cryogenic Balloon Payload

    NASA Technical Reports Server (NTRS)

    Kogut, Alan J.

    2010-01-01

    The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument to measure the frequency spectrum of the cosmic microwave background and diffuse Galactic foregrounds at centimeter wavelengths. ARCADE greatly reduces measurement uncertainties compared to previous balloon-borne or ground-based instrument using a double-nulled design that features fully cryogenic optics with no windows between the atmosphere and the 2.7 K instrument. A four-hour flight in 2006 achieved sensitivity comparable to the COBE/FIRAS satellite measurement while providing new insights for emission ranging from spinning dust in the interstellar medium to an unexpectedly bright extragalactic radio background. I will discuss scientific results from the ARCADE program and implications of the ARCADE cold optics for millimeter and sub-mm astronomy.

  10. Partial stent-in-stent placement of biliary metallic stents using a short double-balloon enteroscopy.

    PubMed

    Tsutsumi, Koichiro; Kato, Hironari; Tomoda, Takeshi; Matsumoto, Kazuyuki; Sakakihara, Ichiro; Yamamoto, Naoki; Noma, Yasuhiro; Sonoyama, Takayuki; Okada, Hiroyuki; Yamamoto, Kazuhide

    2012-12-07

    Endoscopic intervention is less invasive than percutaneous or surgical approaches and should be considered the primary drainage procedure in most cases with obstructive jaundice. Recently, therapeutic endoscopic retrograde cholangiopancreatography (ERCP) using double-balloon enteroscopy (DBE) has been shown to be feasible and effective, even in patients with surgically altered anatomies. On the other hand, endoscopic partial stent-in-stent (PSIS) placement of self-expandable metallic stents (SEMSs) for malignant hilar biliary obstruction in conventional ERCP has also been shown to be feasible, safe and effective. We performed PSIS placement of SEMSs for malignant hilar biliary obstruction due to liver metastasis using a short DBE in a patient with Roux-en-Y anastomosis and achieved technical and clinical success. This procedure can result in quick relief from obstructive jaundice in a single session and with short-term hospitalization, even in patients with surgically altered anatomies.

  11. The detection of high charge cosmic ray nuclei. [by balloon-borne electronic particle telescope

    NASA Technical Reports Server (NTRS)

    Scarlett, W. R.; Freier, P. S.; Waddington, C. J.

    1975-01-01

    A large-area, light-weight electronic particle telescope was flown on a high altitude balloon in the summer of 1974 to study the heavy nuclei in the cosmic radiation. This telescope consisted of a double Cerenkov-double scintillator array composed of four 1.22 m diameter disk radiators mounted in light diffusion boxes, each looked at by multiple photomultipliers. The impact point of each particle on the scintillation radiators was determined by studying the relative signals observed by three equally spaced peripheral photomultipliers and one mounted at the center of the diffusion boxes. This telescope was flown in a configuration having a geometric factor of 0.45 sq m sr and observed some 5 x 10 to the 4 nuclei with Z exceeding 14 in a 11 hr exposure. The response and sensitivity of this telescope are discussed in detail.

  12. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    PubMed

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  13. Elevated Z line: a new sign of Barrett's esophagus on double-contrast barium esophagograms.

    PubMed

    Levine, Marc S; Ahmad, Nuzhat A; Rubesin, Stephen E

    2015-01-01

    We describe an elevated Z line as a new radiographic sign of Barrett's esophagus characterized by a transversely oriented, zigzagging, barium-etched line extending completely across the circumference of the midesophagus. An elevated Z line is rarely seen in other patients, so this finding should be highly suggestive of Barrett's esophagus on double-contrast barium esophagograms. If the patient is a potential candidate for surveillance, endoscopy and biopsy should be performed to confirm the presence of Barrett's esophagus. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Discussion on the Timing of Balloon Occlusion of the Abdominal Aorta during a Caesarean Section in Patients with Pernicious Placenta Previa Complicated with Placenta Accreta

    PubMed Central

    Yang, Kaili; Cai, Lina

    2017-01-01

    Objective This paper is aimed at investigating the role and value of the timing of balloon occlusion of the abdominal aorta during caesarean section in patients with pernicious placenta previa complicated with placenta accreta. Methods 79 cases admitted to the Second Affiliated Hospital of Zhengzhou University from September 2015 to December 2016 were treated with ultrasound mediated abdominal aortic balloon occlusion. Among them, 42 cases, whose balloon occlusion time was selected before the delivery and transverse incision was taken, were group A. The other 37 cases were group B, whose timing of balloon occlusion was selected after the delivery and the uterine incision made trying to avoid the placenta or double incisions. The intraoperative blood loss, utilization of blood, and other indicators were compared between the two groups. Results The intraoperative blood loss in groups A and B was 413.8 ± 105.9 ml and 810.3 ± 180.3 ml, and the utilization of blood products in groups A and B was 30.23% and 89.2%. The total hysterectomy rate was 2.53% (2/79), with no hysterectomies in groups A and 2 cases in group B. Conclusion The balloon occlusion of the abdominal aorta before the delivery combined with a transverse incision is more effective. PMID:29230417

  15. Access to a New Plasma Edge State with High Density and Pressures using Quiescent H-mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solomon, Wayne M.; Snyder, P. B.; Burrell, K. H.

    2014-07-01

    A path to a new high performance regime has been discovered in tokamaks that could improve the attractiveness of a fusion reactor. Experiments on DIII-D using a quiescent H-mode edge have navigated a valley of improved edge peeling-ballooning stability that opens up with strong plasma shaping at high density, leading to a doubling of the edge pressure over standard edge localized mode (ELM)ing H-mode at these parameters. The thermal energy confinement time increases both as a result of the increased pedestal height and improvements in the core transport and reduced low-k turbulence. Calculations of the pedestal height and width asmore » a function of density using constraints imposed by peeling-ballooning and kinetic-ballooning theory are in quantitative agreement with the measurements.« less

  16. Alien crop circle? No, that’s just NASA’s newest balloon launch pad

    NASA Image and Video Library

    2017-12-08

    Aviators, skydivers and other altitude-seeking enthusiasts flying out of Wanaka Airport, New Zealand, are double taking at a new topographical feature reminiscent of an alien crop circle. Rest assured, the nearly 2,000-foot (600-meter) diameter circle with a pie-shaped wedge on one side and spokes on the other is no extraterrestrial footprint and it’s definitely no hoax. It’s NASA’s newest launch pad for launching the agency’s most advanced high-altitude, heavy-lift scientific balloon: the super pressure balloon. The four spokes emanating from the center and toward the west, each nearly 1,000 feet (300 meters) long, align with magnetic compass directions at 240, 260, 290 and 320 degrees. On launch day, balloon flight experts from NASA’s Columbia Scientific Balloon Facility will assess meteorological data and determine if the conditions are suitable to support a launch opportunity. The new pad is the first major project in developing a long-term super pressure balloon launch site in Wanaka. Earlier in 2017, NASA signed a 10-year lease with the Queenstown Airport Corporation to conduct balloon operations from a newly acquired piece of land adjacent to the Wanaka Airport. Credit: NASA/Dave Webb NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  17. Endocytoscopic findings of lymphomas of the stomach

    PubMed Central

    2013-01-01

    Background The gastric lesions of various lymphomas were observed at the cellular level using endocytoscopy. Methods Endocytoscopy and magnifying endoscopy with narrow band imaging (NBI) were performed in 17 patients with lymphomas of the stomach. The lesions consisted of 7 with low-grade mucosa-associated lymphoid tissue (MALT), 5 with gastric involvement by adult T-cell leukemia/lymphoma (ATLL), 4 with diffuse large B-cell lymphoma (DLBCL), and 1 with peripheral T-cell lymphoma. Results On conventional endoscopy, 9 were classified as having superficial spreading type, 7 were mass-forming type, and 1 was diffuse infiltrating type. Anti-H. pylori treatment was given in the 7 MALT lymphoma cases. NBI magnification endoscopy invariably showed dilatation or ballooning and destruction of gastric pits and elongation and distortion in microvessels. Endocytoscopy showed mucosal aggregation of interstitial cellular elements in almost all gastric lymphoma cases. The nuclear diversity in size and configuration was exclusively seen in gastric lymphomas other than MALT lymphoma, whereas the nuclei of MALT lymphoma cells were regular and small to moderate in size. Inter-glandular infiltration by lymphomatous cell elements was frequently observed in MALT lymphoma and DLBCL, but it was uncommon in peripheral gastric T-cell malignancies. Endocytoscopy could identify the disease-specific histology, the lymphoepithelial origin, as inter-glandular infiltration of cellular components in MALT lymphoma and the possibly related DLBCL cases. Complete regression (CR) was observed in 2 of the 7 MALT lymphoma patients. In the 2 patients with CR who underwent repeat endocytoscopy, the ultra-high magnification abnormalities returned to normal, while they were unchanged in those without tumor regression. Conclusions On endocytoscopy, intra-glandular aggregation of cellular components was invariably identified in lymphomas of the stomach. Nuclear regularity in size and configuration may indicate the cytological grade, differentiating the indolent low-grade from aggressive lymphoproliferative diseases. The inter-glandular infiltration seen on endocytoscopy can indicate the lymphoepithelial lesions seen in MALT lymphoma and related DLBCL. Endocytoscopy would be applicable for virtual histopathological diagnosis of different lymphoproliferative disorders and their clinical assessment during ongoing endoscopy. PMID:24369830

  18. Endoscope-guided pneumatic dilation for treatment of esophageal achalasia

    PubMed Central

    Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin

    2010-01-01

    Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764

  19. Jejunal varices after choledochojejunostomy treated with laparotomic transcatheter variceal embolization.

    PubMed

    Waguri, Nobuo; Azumi, Rie; Sugimura, Kazuhito; Arao, Yoshihisa; Ikarashi, Shunzo; Sakai, Norihiro; Ogawa, Masahiro; Osaki, Akihiko; Sato, Munehiro; Aiba, Tsuneo; Yoneyama, Osamu; Furukawa, Koichi; Igarashi, Kentarou

    2016-01-01

    Portal hypertension induces collateral shunt formation between the portal and systemic circulation, decompressing the elevated portal pressure. Ectopic varices outside of the gastroesophageal region, such as jejunal varices, are rare conditions. This report describes the successful embolization of ruptured jejunal varices resulting from an extrahepatic portal obstruction. A 62-year-old man was admitted to our hospital with recurrent massive gastrointestinal bleeding. Fourteen months earlier, he had undergone a choledochojejunostomy and pancreatic cystojejunostomy for bile duct stenosis with an enlarged pancreatic pseudocyst due to severe chronic pancreatitis. Contrast-enhanced computed tomography showed jejunal intramural dilated vessels close to the choledochojejunal anastomosis, but extravasation was not observed. Due to the lack of a rapid definitive diagnosis, the patient required massive blood transfusions. Hemorrhagic scintigraphy using 99m Tc-HSAD finally identified the site of the hemorrhage. Angiography and double-balloon endoscopy revealed the anastomotic jejunal varices to be the result of an extrahepatic portal obstruction. Laparotomic transcatheter variceal embolization with microcoils was successful in halting the refractory gastrointestinal bleeding. This surgery preserved hepatopetal portal venous flow by another route, and no complications were observed. At present, 4 years post-surgery, there has been no recurrence of gastrointestinal hemorrhage. The development of jejunal varices is often associated with postoperative adhesions. Some patients with a history of hepatico- or choledochojejunostomy may experience portal hypertension resulting from extrahepatic portal obstruction, leading to the formation of jejunal varices as hepatopetal portal collaterals. The choice of therapy in each patient should be based on the individual hemodynamics of the ectopic varices.

  20. A case of gastrojejunocolic fistula with steatohepatitis.

    PubMed

    Omori, Teppei; Tokushige, Katsutoshi; Kinoshita, Fukiko; Ito, Ayumi; Taniai, Makiko; Taneichi, Mikiko; Iizuka, Bunei; Itabashi, Michio; Nagashima, Yoji; Yamamoto, Masakazu; Nakamura, Shinichi; Hashimoto, Etsuko

    2017-02-01

    A man in his 30s, who had undergone retrocolic Billroth II reconstruction for perforated duodenal ulcer, presented with watery diarrhea for 2 years and suspected fatty liver. He was referred to our hospital for management of chronic diarrhea, weight loss, hepatopathy and hypoalbuminemia. Initial upper and lower gastrointestinal endoscopies were negative. Since a small bowel lesion was suspected, peroral single-balloon enteroscopy was performed, which identified feces-like residue near the Billroth II anastomotic site and a connection to the colon separate from the afferent and efferent loops. Transanal single-balloon enteroscopy identified a fistula between the gastrojejunal anastomosis and transverse colon, with the scope reaching the stomach transanally. Barium enema confirmed flow of contrast medium from the transverse colon through the fistula to the anastomotic site, allowing the diagnosis of gastrojejunocolic fistula. Liver biopsy showed relatively severe steatohepatitis (Brunt's classification: stage 2-3, grade 3). Resection of the anastomotic site and partial transverse colectomy were performed to remove the fistula, followed by Roux-en-Y reconstruction. Postoperatively, watery diarrhea resolved and the stools became normal. Hepatopathy and hypoproteinemia improved. One year later, liver biopsy showed marked improvement of steatosis. This case demonstrated marked improvement of both diarrhea/nutritional status and steatohepatitis after treatment of gastrojejunocolic fistula, suggesting that the fistula caused non-alcoholic steatohepatitis.

  1. Successful balloon dilatation of both orifices in a case of double-orifice mitral valve with severe rheumatic stenosis.

    PubMed

    Nath, Ranjit Kumar; Soni, Dheeraj Kumar

    2016-08-01

    A 24-year-old female patient presented to us with progressive dyspnea on exertion for last three year. She was not a known case of rheumatic heart disease. Her physical examination showed regular pulse and her blood pressure was 100/76 mm Hg. Cardiac palpation showed grade 3 parasternal heave and auscultation revelled an accentuated first heart sound, loud P2 and mid-diastolic long rumbling murmur at apex and pansystolic murmur of tricuspid regurgitation at lower left sterna border. Chest X-ray showed evidence of grade 3 pulmonary venous congestion. Transthoracic and transesophageal two-dimensional echocardiography revealed a double-orifice mitral valve of complete bridge type at the leaflet level. Both orifice sizes were unequal, with the anterolateral orifice being smaller than its counterpart. There was moderate subvalvular fusion and both commisures were fused. Color doppler examination showed two separate mitral diastolic flows with mean gradients of 22 mm and 20 mm of Hg, respectively. There was no mitral regurgitation and no left atrial or appendage clot was seen by transesophageal echocardiography. Transseptal puncture was done by the modified fluoroscopic method. Posteromedial orifice was crossed with a 24 mm Inoue balloon and dilated using the stepwise dilation technique. Anterolateral orifice was not crossed by Inuoe balloon after multiple attempts. A TYSHAK (NuMAD Canada Inc.) balloon (16 × 40mm) was taken over the wire and inflated successfully across the anterolateral orifice with the help of transthoracic echocardiography guidance. Mean gradient become 9 and 8 mm across the medial and lateral orifice. Patient was discharged in stable condition after two day. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  2. Access to a new plasma edge state with high density and pressures using the quiescent H mode

    DOE PAGES

    Solomon, Wayne M.; Snyder, Philip B.; Burrell, Keith H.; ...

    2014-09-24

    A path to a new high performance regime has been discovered in tokamaks that could improve the attractiveness of a fusion reactor. Experiments on DIII-D using a quiescent H-mode edge have navigated a valley of improved edge peeling-ballooning stability that opens up with strong plasma shaping at high density, leading to a doubling of the edge pressure over the standard H mode with edge localized modes at these parameters. The thermal energy confinement time increases as a result of both the increased pedestal height and improvements in the core transport and reduced low-k turbulence. As a result, calculations of themore » pedestal height and width as a function of density using constraints imposed by peeling-ballooning and kinetic-ballooning theory are in quantitative agreement with the measurements.« less

  3. Interferometry on a Balloon; Paving the Way for Space-based Interferometers

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen A.

    2008-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe, and observations with Spitzer, the upcoming Herschel mission, and SOFIA will continue to provide exciting new discoveries. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to-far-infrared emission arises, resulting in source and structure ambiguities that limit our ability to answer key science questions. Interferometry enables high angular resolution at these wavelengths- a powerful tool for scientific discovery. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII), an eight-meter baseline Michelson stellar interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks in young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers.

  4. The Balloon Experimental Twin Telescope for Infrared Interferometry

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen A.

    2008-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe, and observations with Spitzer, the upcoming Herschel mission, and SOFIA will continue to provide exciting new discoveries. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scales on which mid- to far-infrared emission arises, resulting in source and structure ambiguities that limit our ability to answer key science questions. Interferometry enables high angular resolution at these wavelengths, a powerful tool for scientific discovery, We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETII), an eight-meter baseline Michelson stellar interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks in young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers,

  5. Balloon-borne air traffic management (ATM) as a precursor to space-based ATM

    NASA Astrophysics Data System (ADS)

    Brodsky, Yuval; Rieber, Richard; Nordheim, Tom

    2012-01-01

    The International Space University—Balloon Air traffic control Technology Experiment (I-BATE ) has flown on board two stratospheric balloons and has tracked nearby aircraft by receiving their Automatic Dependent Surveillance-Broadcast (ADS-B) transmissions. Air traffic worldwide is facing increasing congestion. It is predicted that daily European flight volumes will more than double by 2030 compared to 2009 volumes. ADS-B is an air traffic management system being used to mitigate air traffic congestion. Each aircraft is equipped with both a GPS receiver and an ADS-B transponder. The transponder transmits an equipped aircraft's unique identifier, position, heading, and velocity once per second. The ADS-B transmissions can then be received by ground stations for use in traditional air traffic management. Airspace not monitored by these ground stations or other traditional means remains uncontrolled and poorly monitored. A constellation of space-based ADS-B receivers could close these gaps and provide global air traffic monitoring. By flying an ADS-B receiver on a stratospheric balloon, I-BATE has served as a precursor to a constellation of ADS-B-equipped Earth-orbiting satellites. From the ˜30 km balloon altitude, I-BATE tracked aircraft ranging up to 850 km. The experiment has served as a proof of concept for space-based air traffic management and supports a technology readiness level 6 of space-based ADS-B reception. I-BATE: International Space University—Balloon Air traffic control Technology Experiment.

  6. Single Fluid-Filled Intragastric Balloon Safe and Effective for Inducing Weight Loss in a Real-World Population.

    PubMed

    Vargas, Eric J; Pesta, Carl M; Bali, Ahmad; Ibegbu, Eric; Bazerbachi, Fateh; Moore, Rachel L; Kumbhari, Vivek; Sharaiha, Reem Z; Curry, Trace W; DosSantos, Gina; Schmitz, Ramsey; Agnihotri, Abhishek; Novikov, Aleksey A; Pitt, Tracy; Dunlap, Margo K; Herr, Andrea; Aronne, Louis; Ledonne, Erin; Kadouh, Hoda C; Cheskin, Lawrence J; Mundi, Manpreet S; Acosta, Andres; Gostout, Christopher J; Abu Dayyeh, Barham K

    2018-07-01

    The Orbera intragastric balloon (OIB) is a single fluid-filled intragastric balloon approved for the induction of weight loss and treatment of obesity. However, little is known about the effectiveness and safety of the OIB outside clinical trials, and since approval, the Food and Drug Administration has issued warnings to health care providers about risk of balloon hyperinflation requiring early removal, pancreatitis, and death. We analyzed data on patients who have received the OIB since its approval to determine its safety, effectiveness, and tolerance in real-world clinical settings. We performed a postregulatory approval study of the safety and efficacy of the OIB, and factors associated with intolerance and response. We collected data from the Mayo Clinic's database of patient demographics, outcomes of OIB placement (weight loss, weight-related comorbidities), technical aspects of insertion and removal, and adverse events associated with the device and/or procedure, from 8 centers (3 academic, 5 private, 4 surgeons, and 4 gastroenterologists). Our final analysis comprised 321 patients (mean age, 48.1 ± 11.9 y; 80% female; baseline body mass index, 37.6 ± 6.9). Exploratory multivariable linear and logistic regression analyses were performed to identify predictors of success and early balloon removal. Primary effectiveness outcomes were percentage of total body weight lost at 3, 6, and 9 months. Primary and secondary safety outcomes were rates of early balloon removal, periprocedural complications, dehydration episodes requiring intravenous infusion, balloon migration, balloon deflation or hyperinflation, pancreatitis, or other complications. Four patients had contraindications for placement at the time of endoscopy. The balloon was safely removed in all instances with an early removal rate (before 6 months) in 16.7% of patients, at a median of 8 weeks after placement (range, 1-6 mo). Use of selective serotonin or serotonin-norepinephrine re-uptake inhibitors at the time of balloon placement was associated with increased odds of removal before 6 months (odds ratio, 3.92; 95% CI, 1.24-12.41). Total body weight lost at 3 months was 8.5% ± 4.9% (n = 204), at 6 months was 11.8% ± 7.5% (n = 199), and at 9 months was 13.3% ± 10% (n = 47). At 6 months, total body weight losses of 5%, 10%, and 15% were achieved by 88%, 62%, and 31% of patients, respectively. Number of follow-up visits and weight loss at 3 months were associated with increased weight loss at 6 months (β = 0.5 and 1.2, respectively) (P < .05). Mean levels of cholesterol, triglycerides, low-density lipoprotein, and hemoglobin A1c, as well as systolic and diastolic blood pressure, were significantly improved at 6 months after OIB placement (P < .05). In an analysis of a database of patients who received endoscopic placement of the OIB, we found it to be safe, effective at inducing weight loss, and to reduce obesity-related comorbidities in a real-world clinical population. Rates of early removal (before 8 weeks) did not differ significantly between clinical trials and the real-world population, but were affected by use of medications. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  7. Clinical usefulness of single-balloon endoscopy in patients with previously incomplete colonoscopy

    PubMed Central

    Kobayashi, Kiyonori; Mukae, Miyuki; Ogawa, Taishi; Yokoyama, Kaoru; Sada, Miwa; Koizumi, Wasaburo

    2013-01-01

    AIM: To evaluate the clinical usefulness of single-balloon endoscopy (SBE) in patients in whom a colonoscope was technically difficult to insert previously. METHODS: The study group comprised 15 patients (8 men and 7 women) who underwent SBE for colonoscopy (30 sessions). The number of SBE sessions was 1 in 7 patients, 2 in 5 patients, 3 in 1 patient, 4 in 1 patient, and 6 in 1 patient. In all patients, total colonoscopy was previously unsuccessful. The reasons for difficulty in scope passage were an elongated colon in 6 patients, severe intestinal adhesions after open surgery in 4, an elongated colon and severe intestinal adhesions in 2, a left inguinal hernia in 2, and multiple diverticulosis of the sigmoid colon in 1. Three endoscopists were responsible for SBE. The technique for inserting SBE in the colon was basically similar to that in the small intestine. The effectiveness of SBE was assessed on the basis of the success rate of total colonoscopy and the presence or absence of complications. We also evaluated the diagnostic and treatment outcomes of colonoscopic examinations with SBE. RESULTS: Total colonoscopy was successfully accomplished in all sessions. The mean insertion time to the cecum was 22.9 ± 8.9 min (range 9 to 40). Abnormalities were found during 21 sessions of SBE. The most common abnormality was colorectal polyps (20 sessions), followed by radiation colitis (3 sessions) and diverticular disease of the colon (3 sessions). Colorectal polyps were resected endoscopically in 15 sessions. A total of 42 polyps were resected endoscopically, using snare polypectomy in 32 lesions, hot biopsy in 7 lesions, and endoscopic mucosal resection in 3 lesions. Fifty-six colorectal polyps were newly diagnosed on colonoscopic examination with SBE. Histopathologically, these lesions included 2 intramucosal cancers, 42 tubular adenomas, and 2 tubulovillous adenomas. The mean examination time was 48.2 ± 20.0 min (range 25 to 90). Colonoscopic examination or endoscopic treatment with SBE was not associated with any serious complications. CONCLUSION: SBE is a useful and safe procedure in patients in whom a colonoscope is technically difficult to insert. PMID:23515370

  8. Percutaneous Mitral Valvuloplasty in a Mid-Term Pregnant Woman with Severe Rheumatic Mitral Stenosis

    PubMed Central

    Lee, Myoung Mook; Sohn, Dae-Won; Oh, Byung Hee; Kim, Jung Goo; Park, Young Bae; Choi, Yun Shik; Seo, Jung Don; Lee, Young Woo

    1992-01-01

    A 28-year-old woman with severe mitral stenosis underwent percutaneous mitral valvuloplasty at 26 weeks’ gestation. Balloon dilation using a double 18-18 mm balloon resulted in improvement in mean mitral pressure gradient (32 to 8 mmHg) and in calculated mitral valve area (0.9 to 2.4 cm2) without complications and any evidence of fetal distress during procedures with an estimated radiation exposure to the fetus of 0.13 rem. This procedure resulted in the disappearance of symptoms of congestive heart failure and allowed for normal full term spontaneous delivery of a 3.51 kg boy without any complication. PMID:1477032

  9. Retrograde Endopyelotomy with Cutting Balloon™ for Treatment of Ureteropelvic Junction Obstruction in Infants.

    PubMed

    Parente, Alberto; Perez-Egido, Laura; Romero, Rosa Maria; Ortiz, Ruben; Burgos, Laura; Angulo, Jose Maria

    2016-01-01

    The aim of this study is to analyze results of retrograde endopyelotomy with cutting balloon for treatment of ureteropelvic junction obstruction (UPJO) in infants. We routinely treat patients with UPJO under 18 months of age with retrograde high-pressure balloon dilatation of the pelviureteric junction (PUJ). During the procedure, in these cases where narrowing at the PUJ persists, endopyelotomy with cutting balloon is performed. Endopyelotomy is performed over guidewire with 5-mm Cutting Balloon™ under fluoroscopic control. Double-J stents is left in situ for 4 weeks. We retrospectively analyzed the postoperative, clinical, and radiological outcome infants treated with cutting balloon endopyelotomy between 2007 and 2015. Sixteen patients required cutting balloon endopyelotomy to achieve complete resolution of narrowing of the waist observed during high-pressure balloon dilatation of the PUJ. Mean operative time was 35 ± 21 min (mean ± SD) and hospital stay was <24 h in all patients. Complete resolution of the narrowing at the PUJ under fluoroscopy was achieved in all cases, with no perioperative complications. One patient presented with urinary tract infection, postoperatively (Clavien grade II). Preoperatively, all cases had grade IV SFU hydronephrosis with parenchymal thinning. During follow-up, resolution of the hydronephrosis was observed in 11 patients (grade I SFU). In four infants, there was an improvement of the hydronephrosis (grade II SFU) and the renogram curve. In one case, an open pyeloplasty was required due to persistent hydronephrosis and obstructive curve. We believe that endopyelotomy with cutting balloon could be a valid and safe option in minimally invasive management of UPJO in infants.

  10. Primary small-bowel malignancy: update in tumor biology, markers, and management strategies.

    PubMed

    Shenoy, Santosh

    2014-12-01

    Primary small-bowel malignancies (SBM) are rare tumors but their incidence is rising. An estimated 9160 new cases and 1210 deaths due to SBM may occur in the USA in 2014. We review advances made in tumor biology, immunohistochemistry, and discuss treatment strategies for these malignancies. Relevant articles from PubMed/Medline and Embase searches were collected using the phrases "small-bowel adenocarcinoma, gastrointestinal carcinoids, gastrointestinal stromal tumors, small-bowel leiomyosarcoma, and small-bowel lymphoma". Advances in imaging techniques such as wireless capsule endoscopy, CT and MRI enterography, and endoscopy (balloon enteroscopy) along with discovery of molecular markers such as c-kit and PDGFRA for GIST tumors have improved our ability to diagnose, localize, and treat these patients. Early detection and surgical resection offers the best chance for long-term survival in all tumors except bowel lymphoma where chemotherapy plays the main role. Adjuvant therapy with imatinib has improved overall survival for GIST tumors, somatostatin analogs have improved symptoms and also inhibited tumor growth and stabilized metastatic disease in carcinoid disease, but chemotherapy has not improved survival for adenocarcinoma. Recent advances in molecular characterization holds promise in novel targeted therapies. Currently ongoing trials are exploring efficacy of targeted therapies and role of adjuvant therapy for adenocarcinoma and results are awaited. Early detection and aggressive surgical therapy for all localized tumors and lymph node sampling particularly for adenocarcinoma remains the main treatment modality.

  11. Feasibility of spiral enteroscopy in Japanese patients: study in two tertiary hospitals.

    PubMed

    Yamada, Atsuo; Watabe, Hirotsugu; Oka, Shiro; Kogure, Hirofumi; Imagawa, Hiroki; Kobayashi, Yuka; Suzuki, Hirobumi; Watari, Ikue; Aoyama, Taiki; Isayama, Hiroyuki; Yamaji, Yutaka; Fujishiro, Mitsuhiro; Tanaka, Shinji; Koike, Kazuhiko

    2013-07-01

    Despite recent advances in enteroscopy, such as balloon enteroscopy, accessing the small intestine remains challenging. Spiral enteroscopy is a novel technique in which an endoscope is fitted with a rotating overtube that has a soft spiral fin at the tip. Whereas spiral enteroscopy is beginning to be carried out in Western countries, it is not common in many Asian countries. The aim of the present study was to evaluate the efficacy and safety of spiral enteroscopy in Japanese patients. We prospectively conducted spiral enteroscopy in patients with suspected or known small bowel disease. All procedures were carried out using a spiral overtube. The main outcome measurements of the study were diagnosis rate, endoscopic intervention rate, and complication rate. Thirty-two patients underwent spiral enteroscopy. Spiral enteroscopy diagnosed 16 patients (50%) with small intestinal lesions, including six malignant lymphomas (19%), three erosions or ulcers (9%), three polyps (9%), two angioectasias (6%), one carcinoma (3%), and one submucosal tumor (3%). Additionally, four patients underwent endoscopic interventions (13%). Mallory-Weiss syndrome occurred in one patient (3%). No perforation occurred in any patient (0%). Our initial experience of spiral enteroscopy suggests that it can be introduced safely, but it is relatively invasive and technically demanding. More experience is needed to conduct spiral enteroscopy easily and safely. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  12. Long-Duration Altitude-Controlled Balloons for Venus: A Feasibility Study Informed by Balloon Flights in Remote Environments on Earth

    NASA Astrophysics Data System (ADS)

    Voss, P. B.; Nott, J.; Cutts, J. A.; Hall, J. L.; Beauchamp, P. M.; Limaye, S. S.; Baines, K. H.; Hole, L. R.

    2013-12-01

    In situ exploration of the upper atmosphere of Venus, approximately 65-77 km altitude, could answer many important questions (Limaye 2013, Crisp 2013). This region contains a time-variable UV absorber of unknown composition that controls many aspects of the heat balance on Venus. Understanding the composition and dynamics of this unknown absorber is an important science goal; in situ optical and chemical measurements are needed. However, conventional approaches do not provide access to this altitude range, repeated traverses, and a mission lifetime of several months needed to effectively carry out the science. This paper examines concepts for altitude-controlled balloons not previously flown on planetary missions that could potentially provide the desired measurements. The concepts take advantage of the fact that at 60 km altitude, for example, the atmospheric density on Venus is about 40% of the sea-level density on earth and the temperature is a moderate 230 K. The solar flux is approximately double that on earth, creating some thermal challenges, but making photovoltaic power highly effective. Using a steady-state thermodynamic model and flight data from Earth, we evaluate the suitability of two types of altitude-controlled balloons for a potential mission on Venus. Such balloons could repeatedly measure profiles, avoid diurnal temperature extremes, and navigate using wind shear. The first balloon design uses air ballast (AB) whereby ambient air can be compressed into or released from a constant-volume balloon, causing it to descend or ascend accordingly. The second design uses lift-gas compression (LGC) to change the volume of a zero-pressure balloon, thereby changing its effective density and altitude. For an altitude range of 60-75 km on Venus, we find that the superpressure volume for a LGC balloon is about 5% of that needed for an AB balloon while the maximum pressurization is the same for both systems. The compressor work per km descent of the LGC balloon is about 10% of the AB balloon, largely due to the much lower flow rate. The LGC balloon must compress some lift gas at sunrise, but this can be managed by one of several strategies. We conclude that while the weight constraints are likely to be significant, LGC altitude-controlled balloons may be feasible for accessing the 60 to 75 km altitude range on Venus. The underlying concept of balloons on Venus was proven by the Soviet Union's successful deployment of their two superpressure VEGA balloons in 1981 operating at a fixed altitude near 55 km. Superpressure balloon concepts for similar altitudes and larger payloads have since been proposed for NASA's Discovery program and ESA's Cosmic Visions program. The LGC balloon would add a zero-pressure envelope and a compressor to the established superpressure design, allowing it to ascend above the deployment altitude and realize lossless altitude control over a range of several scale heights. The thermodynamic equations, flight data, and conceptual analysis presented are intended to foster further discussion about the feasibility and potential benefits of a balloon mission to Venus.

  13. Nasopharyngeal stenosis with concurrent hiatal hernia and megaesophagus in an 8-year-old cat.

    PubMed

    DeSandre-Robinson, Dana M; Madden, Stacey N; Walker, Jackson T

    2011-06-01

    A case of nasopharyngeal stenosis with secondary hiatal hernia is described. An 8-year-old castrated male domestic shorthair cat was referred for a chronic upper respiratory problem and presumptive vomiting. Despite conservative management by the primary care veterinarian, the cat's condition progressed. The cat was presented to an emergency facility prior to referral to a specialty hospital. On presentation, inspiratory stridor was evident. Thoracic radiography revealed a hiatal hernia. Computed tomography indicated pharyngeal edema and probable nasopharyngeal stenosis. Endoscopy confirmed the presence of nasopharyngeal stenosis consistent with either stricture or choanal atresia. Balloon dilation of the choana was performed. The hiatal hernia regressed spontaneously post-resolution of the nasopharyngeal stenosis. The cat remained asymptomatic at recheck 3 months later. Copyright © 2011 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.

  14. Balloon-assisted enteroscopy for suspected Meckel’s diverticulum and indefinite diagnostic imaging workup

    PubMed Central

    Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira

    2016-01-01

    Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776

  15. The development of a pseudo-chamber after balloon pulmonary angioplasty: long-term complications of balloon pulmonary angioplasty.

    PubMed

    Sugiyama, Hisashi; Kise, Hiroaki; Toda, Takako; Hoshiai, Minako

    2016-11-01

    We experienced a rare complication where extravasation developed a pseudo-chamber long after the balloon pulmonary angioplasty for supravalvular pulmonary stenosis. A 3-month-old girl was diagnosed with an anomalous origin of the left coronary artery from the pulmonary artery. She underwent the Takeuchi procedure at 10 months of age. During the follow-up, the supravalvular pulmonary stenosis deteriorated, and was treated by balloon pulmonary angioplasty with the double balloon technique catheter at 6 years of age. Angiography at the main pulmonary artery showed a small amount of extravasation contrast medium after the procedure. Follow-up echocardiography showed a diminished extravasation hemorrhage. Twelve years later, right ventricular enlargement due to pulmonary regurgitation had been observed on echocardiography. In addition, abnormal echo free space was detected at the left posterior of the left atrium. Enhanced computed tomography clearly demonstrated there was an orifice and extent of the pseudo-chamber. Surgical findings revealed a large tear just distal to the coronary tunnel. We speculated that extravasation blood was limited in the perivascular area early after the procedure but eventually reached the non-adhesive oblique pericardial sinus with age. Consequently, pulmonary to oblique pericardial sinus communication was established and looked like a pseudo-chamber long after the procedure. In conclusion, even if extravasation seems to be limited immediately after the balloon pulmonary angioplasty, it could expand for non-adhesive space and could develop a huge blood space like chamber. Long-term careful observation should be necessary for extravasation of pulmonary artery even with surgical adhesion.

  16. Double-clad photonic crystal fiber coupler for compact nonlinear optical microscopy imaging.

    PubMed

    Fu, Ling; Gu, Min

    2006-05-15

    A 1 x 2 double-clad photonic crystal fiber coupler is fabricated by the fused tapered method, showing a low excess loss of 1.1 dB and a splitting ratio of 97/3 over the entire visible and near-infrared wavelength range. In addition to the property of splitting the laser power, the double-clad feature of the coupler facilitates the separation of a near-infrared single-mode beam from a visible multimode beam, which is ideal for nonlinear optical microscopy imaging. In conjunction with a gradient-index lens, this coupler is used to construct a miniaturized microscope based on two-photon fluorescence and second-harmonic generation. Three-dimensional nonlinear optical images demonstrate potential applications of the coupler to compact all-fiber and nonlinear optical microscopy and endoscopy.

  17. Charles Theodore Dotter: The Father of Intervention

    PubMed Central

    Payne, Misty M.

    2001-01-01

    The 1st percutaneous transluminal angioplasty marked a new era in the treatment of peripheral atherosclerotic lesions. The early techniques used in peripheral percutaneous transluminal angioplasty form the basis for subsequent percutaneous intervention both in the peripheral and coronary arteries and are largely the contribution of Charles Dotter. Dotter was the 1st to describe flow-directed balloon catheterization, the double-lumen balloon catheter, the safety guidewire, percutaneous arterial stenting, and more. This practical genius dedicated his considerable energy to the belief that there is always a better way to treat disease. His personal contributions to clinical medicine, research, and teaching have saved millions of limbs and lives all over the world. PMID:11330737

  18. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII): Spatially Resolved Spectroscopy in the Far-Infrared

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen

    2009-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe, and observations with Spitzer, the upcoming Herschel mission, and SOFIA will continue to provide exciting new discoveries. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to far-infrared emission arises, resulting in source and structure ambiguities that limit our ability to answer key science questions. Interferometry enables high angular resolution at these wavelengths - a powerful tool for scientific discovery. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII), an eight-meter baseline Michelson stellar interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks in young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers and for suborbital programs optimized for studying extrasolar planets.

  19. Comparative analysis of upper gastrointestinal endoscopy, double-contrast upper gastrointestinal barium X-ray radiography, and the titer of serum anti-Helicobacter pylori IgG focusing on the diagnosis of atrophic gastritis.

    PubMed

    Yamamichi, Nobutake; Hirano, Chigaya; Takahashi, Yu; Minatsuki, Chihiro; Nakayama, Chiemi; Matsuda, Rie; Shimamoto, Takeshi; Takeuchi, Chihiro; Kodashima, Shinya; Ono, Satoshi; Tsuji, Yosuke; Fujishiro, Mitsuhiro; Wada, Ryoichi; Mitsushima, Toru; Koike, Kazuhiko

    2016-04-01

    Upper gastrointestinal endoscopy (UGI-ES) and double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) are two major image-based methods to diagnose atrophic gastritis, which is mostly induced by Helicobacter pylori infection. However, there have been few studies directly comparing them. Atrophic gastritis was evaluated using the data of 962 healthy subjects who underwent UGI-ES and UGI-XR within 1 year. Based on UGI-ES and UGI-XR, 602 subjects did not have atrophic gastritis and 254 subjects did have it. Considering UGI-ES-based atrophic gastritis as the standard, sensitivity and specificity of UGI-XR-based atrophic gastritis were 92.0 % (254/276) and 92.8 % (602/649), respectively. The seven-grade Kimura-Takemoto classification of UGI-ES-based atrophic gastritis showed a strong and significant association with the four-grade UGI-XR-based atrophic gastritis. Sensitivity and specificity of serum anti-Helicobacter pylori IgG to detect UGI-ES/UGI-XR-based atrophic gastritis were 89.4 % (227/254) and 99.8 % (601/602), indicating that atrophic gastritis can be overlooked according to serum anti-Helicobacter pylori IgG alone.

  20. Clinical usefulness of adherence to gastro-esophageal reflux disease guideline by Spanish gastroenterologists.

    PubMed

    Mearin, Fermín; Ponce, Julio; Ponce, Marta; Balboa, Agustín; González, Miguel A; Zapardiel, Javier

    2012-09-21

    To investigate usefulness of adherence to gastro-esophageal reflux disease (GERD) guideline established by the Spanish Association of Gastroenterology. Prospective, observational and multicentre study of 301 patients with typical symptoms of GERD who should be managed in accordance with guidelines and were attended by gastroenterologists in daily practice. Patients (aged > 18 years) were eligible for inclusion if they had typical symptoms of GERD (heartburn and/or acid regurgitation) as the major complaint in the presence or absence of accompanying atypical symptoms, such as dyspeptic symptoms and/or supraesophageal symptoms. Diagnostic and therapeutic decisions should be made based on specific recommendations of the Spanish clinical practice guideline for GERD which is a widely disseminated and well known instrument among Spanish in digestive disease specialists. Endoscopy was indicated in 123 (41%) patients: 50 with alarm symptoms, 32 with age > 50 years without alarm symptom. Seventy-two patients (58.5%) had esophagitis (grade A, 23, grade B, 28, grade C, 18, grade D, 3). In the presence of alarm symptoms, endoscopy was indicated consistently with recommendations in 98% of cases. However, in the absence of alarm symptoms, endoscopy was indicated in 33% of patients > 50 years (not recommended by the guideline). Adherence for proton pump inhibitors (PPIs) therapy was 80%, but doses prescribed were lower (half) in 5% of cases and higher (double) in 15%. Adherence regarding duration of PPI therapy was 69%; duration was shorter than recommended in 1% (4 wk in esophagitis grades C-D) or longer in 30% (8 wk in esophagitis grades A-B or in patients without endoscopy). Treatment response was higher when PPI doses were consistent with guidelines, although differences were not significant (95% vs 85%). GERD guideline compliance was quite good although endoscopy was over indicated in patients > 50 years without alarm symptoms; PPIs were prescribed at higher doses and longer duration.

  1. Clinical usefulness of adherence to gastro-esophageal reflux disease guideline by Spanish gastroenterologists

    PubMed Central

    Mearin, Fermín; Ponce, Julio; Ponce, Marta; Balboa, Agustín; González, Miguel A; Zapardiel, Javier

    2012-01-01

    AIM: To investigate usefulness of adherence to gastro-esophageal reflux disease (GERD) guideline established by the Spanish Association of Gastroenterology. METHODS: Prospective, observational and multicentre study of 301 patients with typical symptoms of GERD who should be managed in accordance with guidelines and were attended by gastroenterologists in daily practice. Patients (aged > 18 years) were eligible for inclusion if they had typical symptoms of GERD (heartburn and/or acid regurgitation) as the major complaint in the presence or absence of accompanying atypical symptoms, such as dyspeptic symptoms and/or supraesophageal symptoms. Diagnostic and therapeutic decisions should be made based on specific recommendations of the Spanish clinical practice guideline for GERD which is a widely disseminated and well known instrument among Spanish in digestive disease specialists. RESULTS: Endoscopy was indicated in 123 (41%) patients: 50 with alarm symptoms, 32 with age > 50 years without alarm symptom. Seventy-two patients (58.5%) had esophagitis (grade A, 23, grade B, 28, grade C, 18, grade D, 3). In the presence of alarm symptoms, endoscopy was indicated consistently with recommendations in 98% of cases. However, in the absence of alarm symptoms, endoscopy was indicated in 33% of patients > 50 years (not recommended by the guideline). Adherence for proton pump inhibitors (PPIs) therapy was 80%, but doses prescribed were lower (half) in 5% of cases and higher (double) in 15%. Adherence regarding duration of PPI therapy was 69%; duration was shorter than recommended in 1% (4 wk in esophagitis grades C-D) or longer in 30% (8 wk in esophagitis grades A-B or in patients without endoscopy). Treatment response was higher when PPI doses were consistent with guidelines, although differences were not significant (95% vs 85%). CONCLUSION: GERD guideline compliance was quite good although endoscopy was over indicated in patients > 50 years without alarm symptoms; PPIs were prescribed at higher doses and longer duration. PMID:23002360

  2. Transcervical heller myotomy using flexible endoscopy.

    PubMed

    Spaun, Georg O; Dunst, Christy M; Arnold, Brittany N; Martinec, Danny V; Cassera, Maria A; Swanström, Lee L

    2010-12-01

    Esophageal achalasia is most commonly treated by laparoscopic myotomy. Transesophageal approaches using flexible endoscopy have recently been described. We hypothesized that using techniques and flexible instruments from our NOTES experience through a small cervical incision would be a safer and less traumatic route for esophageal myotomy. The purpose of this study was to evaluate the feasibility, safety, and success rate of using flexible endoscopes to perform anterior or posterior Heller myotomy via a transcervical approach. This animal (porcine) and human cadaver study was conducted at the Legacy Research and Technology Center. Mediastinal operations on ten live, anesthetized pigs and two human cadavers were performed using standard flexible endoscopes through a small incision at the supra-sternal notch. The esophagus was dissected to the phreno-esophageal junction using balloon dilatation in the peri-esophageal space followed by either anterior or posterior distal esophageal myotomy. Success rate was recorded of esophageal dissection to the diaphragm and proximal stomach, anterior and posterior myotomy, perforation, and complication rates. Dissection of the esophagus to the diaphragm and performing esophageal myotomy was achieved in 100% of attempts. Posterior Heller myotomy was always extendable onto the gastric wall, while anterior gastric extension of the myotomy was found to be more difficult (4/4 and 2/8, respectively; P = 0.061). Heller myotomy through a small cervical incision using flexible endoscopes is feasible. A complete Heller myotomy was performed with a higher success rate posteriorly possibly due to less anatomic interference.

  3. Lubiprostone decreases the small bowel transit time by capsule endoscopy: an exploratory, randomised, double-blind, placebo-controlled 3-way crossover study.

    PubMed

    Matsuura, Mizue; Inamori, Masahiko; Endo, Hiroki; Matsuura, Tetsuya; Kanoshima, Kenji; Inoh, Yumi; Fujita, Yuji; Umezawa, Shotaro; Fuyuki, Akiko; Uchiyama, Shiori; Higurashi, Takuma; Ohkubo, Hidenori; Sakai, Eiji; Iida, Hiroshi; Nonaka, Takashi; Futagami, Seiji; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi

    2014-01-01

    The aim of this study was to investigate the usefulness of lubiprostone for bowel preparation and as a propulsive agent in small bowel endoscopy. Six healthy male volunteers participated in this randomized, 3-way crossover study. The subjects received a 24 μg tablet of lubiprostone 60 minutes prior to the capsule ingestion for capsule endoscopy (CE) and a placebo tablet 30 minutes before the capsule ingestion (L-P regimen), a placebo tablet 60 minutes prior to CE and a 24 μg tablet of lubiprostone 30 minutes prior to CE (P-L regimen), or a placebo tablet 60 minutes prior to r CE and a placebo tablet again 30 minutes prior to CE (P-P regimen). The quality of the capsule endoscopic images and the amount of water in the small bowel were assessed on 5-point scale. The median SBTT was 178.5 (117-407) minutes in the P-P regimen, 122.5 (27-282) minutes in the L-P regimen, and 110.5 (11-331) minutes in the P-L regimen (P = 0.042). This study showed that the use of lubiprostone significantly decreased the SBTT. We also confirmed that lubiprostone was effective for inducing water secretion into the small bowel during CE.

  4. [Mitral valvuloplasty with double balloon catheter. Analysis of 200 cases].

    PubMed

    Gomes, N L; Esteves, C A; Braga, S L; Ramos, A I; Meneghelo, Z M; Mattos, L A; Pontes Júnior, S C; Arnoni, A S; Fontes, V F; Sousa, J E

    1992-04-01

    To study the immediate clinical, echocardiographic and hemodynamic results of 200 patients who underwent percutaneous mitral balloon valvotomy (PMV) with double balloon technique. Two hundred patients were submitted to PVM for treatment of congestive heart failure secondary to severe mitral stenosis, between August 1987 to July 1991. Their mean age was 35.2 years, and 86.5% were female patients: 81% of them was in functional class, New York Heart Association (NYHA) III or IV; 4% was in atrial fibrilation and 4% had previous surgical commissurotomy. PMV was successfully performed in 89% of the patients. The mitral valve area, by pressure half time method, increased from 0.91 +/- 0.27 to 2.10 +/- 0.47 cm2, p < 0.001; the mean mitral gradient decreased from 20.86 +/- 6.16 to 4.26 +/- 3.13 mmHg, p < 0.001; the left atrium and mean pulmonary artery pressure decreased from 22.3 +/- 7.1 to 11.9 +/- 8.3 and 36.47 +/- 12.93 to 24.56 +/- 9.98 mmHg, p < 0.001, respectively. Complications related to transeptal technique occurred in 12 patients, which resulted in cardiac tamponade in 5 and death in 1. In 19 patients the punction of the atrial septum could not be performed. Mitral regurgitation (MR) immediately after PMV appeared 1+ or more grade in 50 patients, increased in 8 patients and remained unchanged in 11 patients. Ten patients needed mitral valve replacement in the first 48h after PMV, for treatment of severe MR. PMV produces excellent immediate results and can be considered an alternative to surgery for the relief of mitral stenosis.

  5. Use of N-acetylcysteine plus simethicone to improve mucosal visibility during upper GI endoscopy: a double-blind, randomized controlled trial.

    PubMed

    Monrroy, Hugo; Vargas, Jose Ignacio; Glasinovic, Esteban; Candia, Roberto; Azúa, Emilio; Gálvez, Camila; Rojas, Camila; Cabrera, Natalia; Vidaurre, Josefa; Álvarez, Natalia; González, Jessica; Espino, Alberto; González, Robinson; Parra-Blanco, Adolfo

    2018-04-01

    Upper GI endoscopy (UGE) is essential for the diagnosis of gastrointestinal diseases. Mucus and bubbles may decrease mucosal visibility. The use of mucolytics could improve visualization. Our aim was to determine whether premedication with simethicone or simethicone plus N-acetylcysteine is effective in improving visibility during UGE. This was a randomized, double-blinded, placebo-controlled trial with 2 control groups: no intervention and water 100 mL (W); and 3 intervention groups: simethicone 200 mg (S); S + N-acetylcysteine (NAC) 500 mg (S+NAC500); and S + NAC 1000 mg (S+NAC1000). The solution was ingested 20 minutes before UGE. Gastric visibility was evaluated in 4 segments with a previously described scale. A score of less than 7 points was defined as adequate visibility (AV). Water volume was used to improve visibility, and adverse reactions were evaluated as a secondary outcome. Multiple group comparison was performed using non-parametric one-way analysis of variance (ANOVA). Two hundred thirty patients were included in the study, 68% female, mean age 49 years. The most common indication for UGE was epigastric pain/dyspepsia (33%). AV was more frequent in the S+NAC500 and S+NAC1000 groups (65% and 67%) compared with no intervention (44%, P = .044) and water (41%, P = .022). The gastric total visibility scale (TVS) was significantly better in the S+NAC500 and S+NAC1000 groups compared with water (P = .03 and P = .008). Simethicone was not different from no intervention and water. S+NAC1000 required less water volume to improve visibility. No adverse reactions from the study drugs were observed. Premedication with S+NAC500 and S+NAC1000 improves visibility during UGE. The use of simethicone did not show improvements in gastric visibility. TVS was worse in patients using water alone. (Clinical trial registration number: NCT 01653171.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. All rights reserved.

  6. The Balloon Experimental Twin Telescope for Infrared Interferometry

    NASA Technical Reports Server (NTRS)

    Silverburg, Robert

    2009-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe, and observations with Spitzer, the upcoming Herschel mission, and SOFIA will continue to provide exciting new discoveries. The comparatively low spatial resolution of these missions, however, is insufficient to resolve the physical scales on which mid- to far-infrared emission arises, resulting in source and structure ambiguities that limit our ability to answer key science questions. Interferometry enables high angular resolution at these wavelengths. We have proposed a new high altitude balloon experiment, the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII). High altitude operation makes far-infrared (30- 300micron) observations possible, and BETTII's 8-meter baseline provides unprecedented angular resolution (approx. 0.5 arcsec) in this band. BETTII will use a double-Fourier instrument to simultaneously obtain both spatial and spectral information. The spatially resolved spectroscopy provided by BETTII will address key questions about the nature of disks in young cluster stars and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the groundwork for future space interferometers.

  7. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII): High Angular Resolution Astronomy at Far-Infrared Wavelengths

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen A.

    2008-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe, and observations with Spitzer, the upcoming Herschel mission. and SOFIA will continue to provide exciting new discoveries. The comparatively low spatial resolution of these missions, however. is insufficient to resolve the physical scales on which mid- to far-infrared emission arises, resulting in source and structure ambiguities that limit our ability to answer key science questions. Interferometry enables high angular resolution at these wavelengths. We have proposed a new high altitude balloon experiment, the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII). High altitude operation makes far-infrared (30- 300micron) observations possible, and BETTII's 8-meter baseline provides unprecedented angular resolution (-0.5 arcsec) in this band. BETTII will use a double- Fourier instrument to simultaneously obtain both spatial and spectral informatioT. he spatially resolved spectroscopy provided by BETTII will address key questions about the nature of disks in young cluster stars and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the groundwork for future space interferometers.

  8. [Coronary angioplasty simultaneous with the "kissing" technique in a bifurcation lesion: use of a guidewire, and 2 monorail systems of rapid interchange].

    PubMed

    Escudero, X

    1996-01-01

    Coronary branch occlusion complicating percutaneous coronary angioplasty has been recognized in certain bifurcation lesions. The utilization of double angioplasty systems simultaneously has been called "kissing" because the image of contact between balloons, and has been utilized as an alternative to protect the jeopardized branch or prevent snowplow lesion of the principal artery. The technological advance with the use of wide lumen catheters and low profile dilation balloons make the application of this technique possible in those type of lesions using a single guiding catheter. The present paper describes one case treated with this technique using conventional angioplasty systems in a complex bifurcating lesion of the circumflex artery. Some technical considerations about the procedure are made.

  9. Technical considerations in percutaneous hepatic perfusion--a multi-center experience.

    PubMed

    Antoine, Radcliffe A

    2011-03-01

    Patients diagnosed with primary or metastatic liver cancer face a daunting future that is complicated by limited treatment options. Percutaneous hepatic perfusion is a novel approach to chemotherapy delivery that offers significant benefits over contemporary modalities. Percutaneous hepatic perfusion is a procedure in which a chemotherapeutic agent is administered at high doses via the hepatic artery where it perfuses the liver, is extracted and filtered using a veno-veno bypass circuit, a fenestrated multi-lumen double-balloon catheter, and two biocompatible hemoperfusion filters. Venous access is gained at the groin through the femoral vein after which the catheter is advanced and positioned in the inferior vena cava just below the right atrium.The catheter's proximal and distal balloons are inflated to occlude the inferior vena cava above and below the hepatic veins. The occlusion isolated the chemo-rich venous outflow of the liver from the systemic venous circulation. This maneuver also diverts venous blood returning to the heart from lower extremities of the azygos vein. Once the patient is on bypass, the agent is infused through the hepatic artery where it saturates the liver. The chemo-rich venous outflow is extracted through the double-balloon catheter by the bypass circuit. The blood is continuously filtered and cleared of the agent as it passes through the filters and returned to the patient through a catheter placed in the right internal jugular vein. A phase I study demonstrated efficacy with an overall radiographic response rate of 30% observed in treated patients. In 10 patients with ocular melanoma, a 50% overall response rate was observed, including two complete responses. The technique is minimally invasive and can be performed safely by a well-trained multi-disciplinary team. It offers significant benefits including multiple procedures without risks commonly associated with open abdominal surgery.

  10. Technical Considerations in Percutaneous Hepatic Perfusion—A Multi-Center Experience

    PubMed Central

    Antoine, Radcliffe A.

    2011-01-01

    Abstract: Patients diagnosed with primary or metastatic liver cancer face a daunting future that is complicated by limited treatment options. Percutaneous hepatic perfusion is a novel approach to chemotherapy delivery that offers significant benefits over contemporary modalities. Percutaneous hepatic perfusion is a procedure in which a chemotherapeutic agent is administered at high doses via the hepatic artery where it perfuses the liver, is extracted and filtered using a veno-veno bypass circuit, a fenestrated multi-lumen double-balloon catheter, and two biocompatible hemoperfusion filters. Venous access is gained at the groin through the femoral vein after which the catheter is advanced and positioned in the inferior vena cava just below the right atrium. The catheter’s proximal and distal balloons are inflated to occlude the inferior vena cava above and below the hepatic veins. The occlusion isolated the chemo-rich venous outflow of the liver from the systemic venous circulation. This maneuver also diverts venous blood returning to the heart from lower extremities of the azygos vein. Once the patient is on bypass, the agent is infused through the hepatic artery where it saturates the liver. The chemorich venous outflow is extracted through the double-balloon catheter by the bypass circuit. The blood is continuously filtered and cleared of the agent as it passes through the filters and returned to the patient through a catheter placed in the right internal jugular vein. A phase I study demonstrated efficacy with an overall radiographic response rate of 30% observed in treated patients. In 10 patients with ocular melanoma, a 50% overall response rate was observed, including two complete responses. The technique is minimally invasive and can be performed safely by a well-trained multi-disciplinary team. It offers significant benefits including multiple procedures without risks commonly associated with open abdominal surgery. PMID:21449232

  11. Velopharyngeal Dysfunction Evaluation and Treatment.

    PubMed

    Meier, Jeremy D; Muntz, Harlan R

    2016-11-01

    Velopharyngeal dysfunction (VPD) can significantly impair a child's quality of life and may have lasting consequences if inadequately treated. This article reviews the work-up and management options for patients with VPD. An accurate perceptual speech analysis, nasometry, and nasal endoscopy are helpful to appropriately evaluate patients with VPD. Treatment options include nonsurgical management with speech therapy or a speech bulb and surgical approaches including double-opposing Z-plasty, sphincter pharyngoplasty, pharyngeal flap, or posterior wall augmentation. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Endoscopic therapy of posttransplant biliary stenoses after right-sided adult living donor liver transplantation.

    PubMed

    Zoepf, Thomas; Maldonado-Lopez, Evelyn J; Hilgard, Philip; Schlaak, Joerg; Malago, Massimo; Broelsch, Christoph E; Treichel, Ulrich; Gerken, Guido

    2005-11-01

    Endoscopic treatment of biliary strictures after liver transplantation is a therapeutic challenge. In particular, outcomes of endoscopic therapy of biliary complications in the case of duct-to-duct anastomosis after living related liver transplantation are limited. The aim of this study was to evaluate the feasibility and success of an endoscopic treatment approach to posttransplant biliary strictures (PTBS) after right-sided living donor liver transplantation (RLDLT) with duct-to-duct anastomosis. Ninety patients who received adult-to-adult RLDLT in our center were screened retrospectively with respect to endoscopic treatment of PTBS. Therapy was judged as successful when cholestasis parameters returned to normal and bile duct narrowing was reduced significantly after the completion of therapy. Forty of 90 RLDLT patients received duct-to-duct anastomosis, 12 (30%) showed PTBS. Seven of 12 patients were treated successfully by endoscopy; the remaining 5 patients were treated primarily by surgery. Most patients were treated by balloon dilatation followed by insertion of endoprostheses. A median of 2.5 dilatation sessions were necessary and the median treatment duration was 8 months. One patient developed endoscopy-treatable recurrent stenosis, no surgical intervention was necessary. Mild pancreatitis occurred in 7.9% and cholangitis in 5.3% of the procedures. One minor bleeding episode occurred during sphincterotomy. Bleeding was managed endoscopically. Endoscopic therapy of adult-to-adult right living related liver transplantation with duct-to-duct anastomosis is feasible and frequently is successful. The duct-to-duct anastomosis offers the possibility of endoscopic treatment. Endoscopic treatment of posttransplant biliary strictures is safe, with a low specific complication rate.

  13. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.

    PubMed

    Kogure, Hirofumi; Isayama, Hiroyuki; Nakai, Yousuke; Tsujino, Takeshi; Matsubara, Saburo; Yashima, Yoko; Ito, Yukiko; Hamada, Tsuyoshi; Takahara, Naminatsu; Miyabayashi, Koji; Mizuno, Suguru; Mohri, Dai; Kawakubo, Kazumichi; Sasaki, Takashi; Yamamoto, Natsuyo; Hirano, Kenji; Sasahira, Naoki; Tada, Minoru; Koike, Kazuhiko

    2014-01-01

    Endoscopic bilateral self-expandable metallic stent (SEMS) placement in a stent-in-stent method for malignant hilar biliary obstruction is technically challenging. Technical difficulties in the initial placement and reinterventions for stent occlusion are disadvantages inherent to this stent-in-stent method. We previously reported the feasibility of Niti-S large cell D-type biliary stents (LCD). This multicenter prospective consecutive study evaluated the efficacy of bilateral SEMS placement using modified LCD with large and uniform cells, a slimmer delivery system and high radial force. From July 2010 to June 2011, 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent endoscopic bilateral placement of modified LCD in a stent-in-stent method at three tertiary hospitals. Ten patients had gallbladder cancer, eight had cholangiocarcinoma, four had lymph node metastasis, two had intrahepatic cholangiocarcinoma, and two had liver metastasis. Single-session and final technical success rate was 96% and 100%, respectively. Functional success rate was 89%. Stent occlusion occurred in 11 patients (42%) because of sludge (n = 7) or tumor ingrowth (n = 4). Endoscopic bilateral reintervention was technically easy and successful: six patients had stent clearance by balloon sweeping and five had plastic stent placement. According to Kaplan-Meier analysis, median survival and stent patency were 220 days and 157 days, respectively. Modified LCD achieved a high technical success rate both in the initial stent-in-stent placement and in bilateral reinterventions in patients with malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  14. Capturing and stitching images with a large viewing angle and low distortion properties for upper gastrointestinal endoscopy

    NASA Astrophysics Data System (ADS)

    Liu, Ya-Cheng; Chung, Chien-Kai; Lai, Jyun-Yi; Chang, Han-Chao; Hsu, Feng-Yi

    2013-06-01

    Upper gastrointestinal endoscopies are primarily performed to observe the pathologies of the esophagus, stomach, and duodenum. However, when an endoscope is pushed into the esophagus or stomach by the physician, the organs behave similar to a balloon being gradually inflated. Consequently, their shapes and depth-of-field of images change continually, preventing thorough examination of the inflammation or anabrosis position, which delays the curing period. In this study, a 2.9-mm image-capturing module and a convoluted mechanism was incorporated into the tube like a standard 10- mm upper gastrointestinal endoscope. The scale-invariant feature transform (SIFT) algorithm was adopted to implement disease feature extraction on a koala doll. Following feature extraction, the smoothly varying affine stitching (SVAS) method was employed to resolve stitching distortion problems. Subsequently, the real-time splice software developed in this study was embedded in an upper gastrointestinal endoscope to obtain a panoramic view of stomach inflammation in the captured images. The results showed that the 2.9-mm image-capturing module can provide approximately 50 verified images in one spin cycle, a viewing angle of 120° can be attained, and less than 10% distortion can be achieved in each image. Therefore, these methods can solve the problems encountered when using a standard 10-mm upper gastrointestinal endoscope with a single camera, such as image distortion, and partial inflammation displays. The results also showed that the SIFT algorithm provides the highest correct matching rate, and the SVAS method can be employed to resolve the parallax problems caused by stitching together images of different flat surfaces.

  15. Submucosal tunneling using endoscopic submucosal dissection for peritoneal access and closure in natural orifice transluminal endoscopic surgery: a porcine survival study.

    PubMed

    Yoshizumi, F; Yasuda, K; Kawaguchi, K; Suzuki, K; Shiraishi, N; Kitano, S

    2009-08-01

    Safe peritoneal access and gastric closure are the most important concerns in the clinical application of natural orifice transluminal endoscopic surgery (NOTES). We aimed to clarify the feasibility of a submucosal tunnel technique using endoscopic submucosal dissection (ESD) for transgastric peritoneal access and subsequent closure for NOTES. Seven female pigs, each weighing about 40 kg were included in the study. The following procedures were performed: (i) after injection of normal saline into the submucosa, the mucosa was cut with a flex knife; (ii) the submucosal layer was dissected using an insulation-tipped electrosurgical knife to make a narrow longitudinal 50-mm submucosal tunnel; (iii) a small incision was made at the end of the tunnel and enlarged with a dilation balloon. After transgastric peritoneoscopy, the mucosal incision site was closed with clips. The following outcome measures were used: (a) evaluation of the technical feasibility of making a submucosal tunnel; (b) clinical monitoring for 7 days; (c) follow-up endoscopy and necropsy; and (d) peritoneal fluid culture. Natural orifice transluminal endoscopic peritoneoscopy with a submucosal tunnel was successfully carried out in all pigs. The pigs recovered well, without signs of peritonitis. Follow-up endoscopy showed healing of mucosal incision sites without open defects. Necropsy revealed no findings of peritonitis, confirming completeness of gastric closure; there was a thin scar in one pig and adhesion of the omentum in six pigs. Peritoneal fluid culture demonstrated no bacterial growth. The submucosal tunnel technique is feasible and effective for transgastric peritoneal access and closure.

  16. Lubiprostone neither decreases gastric and small-bowel transit time nor improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled study.

    PubMed

    Hooks, S Bennett; Rutland, Travis J; Di Palma, Jack A

    2009-11-01

    Lubiprostone, a selective activator of type 2 chloride channels, is approved for treatment of chronic idiopathic constipation and recently constipation-predominant irritable bowel syndrome. It has been suggested that lubiprostone has a prokinetic effect. This investigation was designed to evaluate lubiprostone as a preparation and propulsive agent for small-bowel capsule endoscopy. The PillCam Small Bowel capsule endoscopy system with the PillCam SB1 capsule and Rapid 5 software platform were used. The study was designed as a double-blind, placebo-controlled trial. Forty healthy adults. Gastric transit time (GTT), small-bowel transit time (SBTT), and adequacy of small-bowel cleansing preparation. The study subjects received 24 mug lubiprostone or placebo 30 minutes before PillCam capsule ingestion. Capsule endoscopy studies were read by 2 independent investigators unaware of the study medication received, and differences in interpretation were resolved by consensus. Anatomical landmarks were identified, and GTT and SBTT were calculated. Overall preparation quality assessment of the proximal, mid, and distal small bowel was determined by using a 4-step scale. The percentage of visualized bowel was determined by review of 10-minute video segments at 1-hour intervals after the capsule passed through the pylorus. In the lubiprostone group (n = 20), 2 subjects did not pass the capsule through the pylorus in the 8-hour battery life of the capsule. An additional 3 capsules did not pass into the colon. In the placebo group (n = 20), all capsules passed into the small bowel, but 1 did not pass into the colon. The subjects in whom the capsule did not pass into the small bowel were excluded from the small-bowel analysis. In the subjects in whom the capsule did reach the colon, the SBTT could not be calculated and they were excluded from SBTT analysis. The mean GTT in the lubiprostone group was 126 minutes and 43 minutes in the placebo group (P = .0095). The mean SBTT in the lubiprostone group was 188 minutes and 219 minutes in the placebo group (P = .130). The overall preparation assessment of the small bowel was not statistically significant between the 2 groups in the proximal, mid, or distal small bowel (proximal, P = .119; mid, P = .118; distal, P = .121). There was no significant difference in lubiprostone compared with placebo in the percentage of visualized small bowel. Some capsules did not leave the stomach or reach the cecum. Lubiprostone produced a significant increase in GTT but did not result in a significant decrease in SBTT compared with placebo. The administration of lubiprostone before capsule ingestion did not result in improved overall preparation of the small bowel for capsule endoscopy or increase the percentage of visualized small bowel. (The trial was registered at www.clinicaltrials.gov, identifier NCT00746395.).

  17. The Electron Calorimeter (ECAL) Long Duration Balloon Experiment

    NASA Technical Reports Server (NTRS)

    Guzik, T. G.; Adams, J. H.; Bashindzhagyan, G.; Binns, W. R.; Chang, J.; Cherry, M. L.; Christl, M.; Dowkontt, P.; Ellison, B.; Isbert, J. B.; hide

    2007-01-01

    Accurate measurements of the cosmic ray electron energy spectrum in the energy region 50 GeV to greater than 1 TeV may reveal structure caused by the annihilation of exotic dark matter particles and/or individual cosmic ray sources. Here we describe a new long duration balloon (LDB) experiment, ECAL, optimized to directly measure cosmic ray electrons up to several TeV. ECAL includes a double layer silicon matrix, a scintillating optical fiber track imager, a neutron detector and a fully active calorimeter to identify more than 90% of the incident electrons with an energy resolution of about 1.7% while misidentifying only 1 in 200,000 protons and 0.8% of secondary gamma rays as electrons. Two ECAL flights in Antarctica are planned for a total exposure of 50 days with the first flight anticipate for December 2009.

  18. Recovery of normal esophageal function in a kitten with diffuse megaesophagus and an occult lower esophageal stricture.

    PubMed

    Schneider, Jaycie; Ames, Marisa; DiCicco, Michael; Savage, Mason; Atkins, Clarke; Wood, Michael; Gookin, Jody L

    2015-06-01

    An 8-week-old male domestic shorthair was presented to the Internal Medicine Service at North Carolina State University for regurgitation. Radiographic diagnosis of generalized esophageal dilation and failure of esophageal peristalsis were compatible with diagnosis of congenital megaesophagus. Endoscopic examination of the esophagus revealed a fibrous stricture just orad to the lower esophageal sphincter. Conservative management to increase the body condition and size of the kitten consisted of feeding through a gastrostomy tube, during which time the esophagus regained normal peristaltic function, the stricture orifice widened in size and successful balloon dilatation of the stricture was performed. Esophageal endoscopy should be considered to rule out a stricture near the lower esophageal sphincter in kittens with radiographic findings suggestive of congenital megaesophagus. Management of such kittens by means of gastrostomy tube feeding may be associated with a return of normal esophageal motility and widening of the esophageal stricture, and facilitate subsequent success of interventional dilation of the esophageal stricture. © ISFM and AAFP 2014.

  19. Emerging fiber optic endomicroscopy technologies towards noninvasive real-time visualization of histology in situ

    NASA Astrophysics Data System (ADS)

    Xi, Jiefeng; Zhang, Yuying; Huo, Li; Chen, Yongping; Jabbour, Toufic; Li, Ming-Jun; Li, Xingde

    2010-09-01

    This paper reviews our recent developments of ultrathin fiber-optic endomicroscopy technologies for transforming high-resolution noninvasive optical imaging techniques to in vivo and clinical applications such as early disease detection and guidance of interventions. Specifically we describe an all-fiber-optic scanning endomicroscopy technology, which miniaturizes a conventional bench-top scanning laser microscope down to a flexible fiber-optic probe of a small footprint (i.e. ~2-2.5 mm in diameter), capable of performing two-photon fluorescence and second harmonic generation microscopy in real time. This technology aims to enable realtime visualization of histology in situ without the need for tissue removal. We will also present a balloon OCT endoscopy technology which permits high-resolution 3D imaging of the entire esophagus for detection of neoplasia, guidance of biopsy and assessment of therapeutic outcome. In addition we will discuss the development of functional polymeric fluorescent nanocapsules, which use only FAD approved materials and potentially enable fast track clinical translation of optical molecular imaging and targeted therapy.

  20. Diagnosis and treatment of superficial esophageal cancer.

    PubMed

    Barret, Maximilien; Prat, Frédéric

    2018-01-01

    Endoscopy allows for the screening, early diagnosis, treatment and follow up of superficial esophageal cancer. Endoscopic submucosal dissection has become the gold standard for the resection of superficial squamous cell neoplasia. Combinations of endoscopic mucosal resection and radiofrequency ablation are the mainstay of the management of Barrett's associated neoplasia. However, protruded, non-lifting or large lesions may be better managed by endoscopic submucosal dissection. Novel ablation tools, such as argon plasma coagulation with submucosal lifting and cryoablation balloons, are being developed for the treatment of residual Barrett's esophagus, since iatrogenic strictures still hamper the development of extensive circumferential resections in the esophagus. Optimal surveillance modalities after endoscopic resection are still to be determined. The assessment of the risk of lymph-node metastases, as well as of the need for additional treatments based on qualitative and quantitative histological criteria, balanced to the patient's condition, requires a dedicated multidisciplinary team decision process. The need for trained endoscopists, expert pathologists and surgeons, and specialized multidisciplinary meetings underlines the role of expert centers in the management of superficial esophageal cancer.

  1. Congenital esophageal stenosis diagnosed in an infant at 9 month of age.

    PubMed

    Savino, F; Tarasco, V; Viola, S; Locatelli, E; Sorrenti, M; Barabino, A

    2015-10-06

    Esophageal stenosis is a relatively uncommon condition in pediatrics and requires an accurate diagnostic approach. Here we report the case of a 9-month old female infant who presented intermittent vomiting, dysphagia and refusal of solid foods starting after weaning. She was treated for gastroesophageal reflux. At first, radiological investigation suggested achalasia, while esophagoscopy revelaed a severe congenital esophageal stenosis at the distal third of the esophagus. She underwent four endoscopic balloon dilatations that then allowed her to swallow solid food with intermittent mild dysphagia. After 17 months of esomeprazole treatment off therapy impedance-pH monitoring was normal. At 29 months of follow-up the child is asymptomatic and eats without problems.Infants with dysphagia and refusal of solid foods may have undiagnosed medical conditions that need treatment. Many disorders can cause esophageal luminal stricture; in the pediatric age the most common are peptic or congenital. Careful assessment with endoscopy is needed to diagnose these conditions early and referral to a pediatric gastroenterologic unit may be necessary.

  2. Protein C deficiency related obscure gastrointestinal bleeding treated by enteroscopy and anticoagulant therapy.

    PubMed

    Hsu, Wei-Fan; Tsang, Yuk-Ming; Teng, Chung-Jen; Chung, Chen-Shuan

    2015-01-21

    Obscure gastrointestinal bleeding is an uncommonly encountered and difficult-to-treat clinical problem in gastroenterology, but advancements in endoscopic and radiologic imaging modalities allow for greater accuracy in diagnosing obscure gastrointestinal bleeding. Ectopic varices account for less than 5% of all variceal bleeding cases, and jejunal variceal bleeding due to extrahepatic portal hypertension is rare. We present a 47-year-old man suffering from obscure gastrointestinal bleeding. Computed tomography of the abdomen revealed multiple vascular tufts around the proximal jejunum but no evidence of cirrhosis, and a visible hypodense filling defect suggestive of thrombus was visible in the superior mesenteric vein. Enteroscopy revealed several serpiginous varices in the proximal jejunum. Serologic data disclosed protein C deficiency (33.6%). The patient was successfully treated by therapeutic balloon-assisted enteroscopy and long-term anticoagulant therapy, which is normally contraindicated in patients with gastrointestinal bleeding. Diagnostic modalities for obscure gastrointestinal bleeding, such as capsule endoscopy, computed tomography enterography, magnetic resonance enterography, and enteroscopy, were also reviewed in this article.

  3. Postoperative vesicoureteral reflux after high-pressure balloon dilation of the ureterovesical junction in primary obstructive megaureter. Incidence, management and predisposing factors.

    PubMed

    García-Aparicio, Luis; Blázquez-Gómez, Eva; de Haro, Irene; Garcia-Smith, Natalie; Bejarano, Miguel; Martin, Oriol; Rodo, Joan

    2015-12-01

    To describe the incidence, predisposing factors and management of postoperative vesicoureteral reflux (VUR) after high-pressure balloon dilation to treat primary obstructive megaureter (POM). We have reviewed patients that underwent endoscopic treatment for POM from May 2008 to November 2013. All patients were evaluated with renal ultrasound, voiding cystourethrography and diuretic renogram. Endoscopic treatment was done with high-pressure balloon dilation of the ureterovesical junction under general anesthesia; a double-J stenting was done in all patients. Follow-up was performed with ultrasonography, voiding cystourethrography and a diuretic renogram in all patients. Fifteen boys and five girls with a mean age of 14.18 months (3-103) were reviewed. A total of 22 ureters underwent HPBD to treat POM. Ureterohydronephrosis improves in 19 ureters. After endoscopic treatment, six ureters developed VUR. Four ureters were managed surgically, and in the other two, VUR disappeared in a second cystogram. The presence of parameatal diverticulum in the preoperative cystography and those patients with bilateral POM are factors related to postoperative VUR (p < 0.05). Urinary tract infection after HPBD was observed in four patients, but only one of them was affected with VUR.

  4. Present status of endoscopy, therapeutic endoscopy and the endoscopy training system in Indonesia.

    PubMed

    Makmun, Dadang

    2014-04-01

    Recently, Indonesia was ranked as the fourth most populous country in the world. Based on 2012 data, 85000 general practitioners and 25000 specialists are in service around the country. Gastrointestinal (GI) disease remains the most common finding in daily practise, in both outpatient and inpatient settings, and ranks fifth in causing mortality in Indonesia. Management of patients with GI disease involves all health-care levels with the main portion in primary health care. Some are managed by specialists in secondary health care or are referred to tertiary health care. GI endoscopy is one of the main diagnostic and therapeutic modalities in the management of GI disease. Development of GI endoscopy in Indonesia started before World War II and, today, many GI endoscopy procedures are conducted in Indonesia, both diagnostic and therapeutic. Based on August 2013 data, there are 515 GI endoscopists in Indonesia. Most GI endoscopists are competent in carrying out basic endoscopy procedures, whereas only a few carry out advanced endoscopy procedures, including therapeutic endoscopy. Recently, the GI endoscopy training system in Indonesia consists of basic GI endoscopy training of 3-6 months held at 10 GI endoscopy training centers. GI endoscopy training is also eligible as part of a fellowship program of consultant gastroenterologists held at six accredited fellowship centers in Indonesia. Indonesian Society for Digestive Endoscopy in collaboration with GI endoscopy training centers in Indonesia and overseas has been working to increase quality and number of GI endoscopists, covering both basic and advanced GI endoscopy procedures. © 2014 The Author. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  5. Correlation analysis of 1 to 30 MeV celestial gamma rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, J.L.

    1984-01-01

    This paper outlines the development of a method of producing celestial sky maps from the data generated by the University of California, Riverside's double Compton scatter gamma ray telescope. The method makes use of a correlation between the telescope's data and theoretical calculated response functions. The results of applying this technique to northern hemisphere data obtained from a 1978 balloon flight from Palestine, Texas are included.

  6. Risk Factors of Acute Pancreatitis in Oral Double Balloon Enteroscopy.

    PubMed

    Kopáčová, Marcela; Bureš, Jan; Rejchrt, Stanislav; Vávrová, Jaroslava; Bártová, Jolana; Soukup, Tomáš; Tomš, Jan; Tachecí, Ilja

    Double balloon enteroscopy (DBE) was introduced 15 years ago. The complications of diagnostic DBE are rare, acute pancreatitis is most redoubtable one (incidence about 0.3%). Hyperamylasemia after DBE seems to be a rather common condition respectively. The most probable cause seems to be a mechanical straining of the pancreas. We tried to identify patients in a higher risk of acute pancreatitis after DBE. We investigated several laboratory markers before and after DBE (serum cathepsin B, lactoferrin, E-selectin, SPINK 1, procalcitonin, S100 proteins, alfa-1-antitrypsin, hs-CRP, malondialdehyde, serum and urine amylase and serum lipase). Serum amylase and lipase rose significantly with the maximum 4 hours after DBE. Serum cathepsin and procalcitonin decreased significantly 4 hours after DBE compared to healthy controls and patients values before DBE. Either serum amylase or lipase 4 hours after DBE did not correlate with any markers before DBE. There was a trend for an association between the number of push-and-pull cycles and procalcitonin and urine amylase 4 hours after DBE; between procalcitonin and alfa-1-antitrypsin, cathepsin and hs-CRP; and between E-selectin and malondialdehyde 4 hours after DBE. We found no laboratory markers determinative in advance those patients in a higher risk of acute pancreatitis after DBE.

  7. Esophageal capsule endoscopy is not the optimal technique to determine the need for primary prophylaxis in patients with cirrhosis

    PubMed Central

    Krok, Karen L.; Wagennar, Rebecca Rankin; Kantsevoy, Sergey V.

    2016-01-01

    Introduction Capsule endoscopy has been suggested as a potential alternative to endoscopy for detection of esophagogastric varices and severe portal hypertensive gastropathy (PHG). The aim of the study was to determine whether PillCam esophageal capsule endoscopy could replace endoscopy for screening purposes. Material and methods Sixty-two patients with cirrhosis with no previous variceal bleeding had PillCam capsule endoscopy and video endoscopy performed on the same day. Sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of capsule endoscopy were compared to endoscopy for the presence and severity of esophageal and gastric varices, PHG and the need for primary prophylaxis. Patients’ preference was assessed by a questionnaire. Results Four (6%) patients were unable to swallow the capsule. Sensitivity, specificity, PPV and NPV of capsule endoscopy for detecting any esophageal varices (92%, 50%, 92%, 50%), large varices (55%, 91%, 75%, 80%), variceal red signs (58%, 87%, 69%, 80%), PHG (95%, 50%, 95%, 50%), and the need for primary prophylaxis (91%, 57%, 78%, 80%) were not optimal, with only moderate agreement (κ) between capsule and upper GI endoscopy. Had only a capsule endoscopy been performed, 12 (21.4%) patients would have received inappropriate treatment. Capsule endoscopy also failed to detect (0/13) gastric varices. The majority of patients ranked capsule endoscopy as more convenient (69%) and their preferred (61%) method. Conclusions Despite the preference expressed by patients for capsule endoscopy, we believe that upper GI endoscopy should remain the preferred screening method for primary prophylaxis. PMID:27186182

  8. A double Gerdien instrument for simultaneous bipolar air conductivity measurements on balloon platforms.

    PubMed

    Nicoll, K A; Harrison, R G

    2008-08-01

    A bipolar air conductivity instrument is described for use with a standard disposable meteorological radiosonde package. It is intended to provide electrical measurements at cloud boundaries, where the ratio of the bipolar air conductivities is affected by the presence of charged particles. The sensors are two identical Gerdien-type electrodes, which, through a voltage decay method, measure positive and negative air conductivities simultaneously. Voltage decay provides a thermally stable approach and a novel low current leakage electrometer switch is described which initiates the decay sequence. The radiosonde supplies power and telemetry, as well as measuring simultaneous meteorological data. A test flight using a tethered balloon determined positive (sigma(+)) and negative (sigma(-)) conductivities of sigma(+)=2.77+/-0.2 fS m(-1) and sigma(-)=2.82+/-0.2 fS m(-1), respectively, at 400 m aloft, with sigma(+)sigma(-)=0.98+/-0.04.

  9. Radiation profiles through the atmosphere measured by an auto controlled glider aircraft

    NASA Astrophysics Data System (ADS)

    Kräuchi, Andreas; Philipona, Rolf

    2014-05-01

    In 2011 radiation measurements through the atmosphere were made with a balloon borne short- and longwave net radiometer. These measurements were very promising and therefore new and improved sensors from Kipp&Zonen were used to equip a glider aircraft together with the standard Swiss radiosonde from Meteolabor AG. The glider serves as returning platform for the expensive and well calibrated radiation sensors. Double balloon technique is used to prevent pendulum motion during the ascent and to keep the radiation instruments as horizontal as possible. The built-in autopilot allows to return the gliderradiosonde to the launch site or to land it on predefined open space, which makes recovery much easier. The new return gliderradiosonde technique as well as new measurement possibilities will be shown. First measurements show radiation profiles through the atmosphere during different cloud conditions. Radiation profiles during different daytimes show the temporal resolution of vertical radiation profiles trough the atmosphere.

  10. Search for medium-energy gamma-ray pulsars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sweeney, W.E. Jr.

    1987-01-01

    Results are presented from a search for pulsed gamma rays from four radio pulsars, chosen for their interest to gamma-ray astronomers in previous studies. The data set used for the search consists of gamma-ray events at energies of 1-30 MeV, detected during a 40-hour balloon flight of the UCR double Compton scatter telescope launched at the National Scientific Balloon Facility in Palestine, Texas, USA on September 30, 1978. No statistically significant signals were detected from any of the pulsars. Three sigma upper limits to pulsed 1-30 MeV gamma ray flux from PSR 0950+08, PSR 1822+09, PSR 1929+10, and PSR 1953+29more » are presented. Two complete exposures to PSR 0950+08 were obtained. The reported tentative detection of 1-20 MeV gamma rays from PSR 0950+08 is not confirmed.« less

  11. Airway reconstruction: review of an approach to the advanced-stage laryngotracheal stenosis.

    PubMed

    Bitar, Mohamad Ahmad; Al Barazi, Randa; Barakeh, Rana

    The management of laryngotracheal stenosis is complex and is influenced by multiple factors that can affect the ultimate outcome. Advanced lesions represent a special challenge to the treating surgeon to find the best remedying technique. To review the efficacy of our surgical reconstructive approach in managing advanced-stage laryngotracheal stenosis treated at a tertiary medical center. A retrospective review of all patients that underwent open laryngotracheal repair/reconstruction by the senior author between 2002 and 2014. Patients with mild/moderate stenosis (e.g. stage 1 or 2), or those who had an open reconstructive procedure prior to referral, were excluded. Patients who had only endoscopic treatment (e.g. laser, balloon dilatation) and were not subjected to an open reconstructive procedure at our institution, were not included in this study. Variables studied included patient demographics, clinical presentation, etiology of the laryngotracheal pathology, the location of stenosis, the stage of stenosis, the type of corrective or reconstructive procedure performed with the type of graft used (where applicable), the type and duration of stent used, the post-reconstruction complications, and the duration of follow-up. Outcome measures included decannulation rate, total number of reconstructive surgeries needed to achieve decannulation, and the number of post-operative endoscopies needed to reach a safe patent airway. Twenty five patients were included, aged 0.5 months to 45 years (mean 13.5 years, median 15 years) with 16 males and 9 females. Seventeen patients (68%) were younger than 18 years. Most patients presented with stridor, failure of decannulation, or respiratory distress. Majority had acquired etiology for their stenosis with only 24% having a congenital pathology. Thirty-two reconstructive procedures were performed resulting in decannulating 24 patients (96%), with 15/17 (88%) pediatric patients and 5/8 (62.5%) adult patients requiring only a single reconstructive procedure. Cartilage grafts were mostly used in children (84% vs. 38%) and stents were mostly silicone made, followed by endotracheal tubes. The number of endoscopies required ranged from 1 to 7 (mean 3). More co-morbidities existed in young children, resulting in failure to decannulate one patient. Adult patients had more complex pathologies requiring multiple procedures to achieve decannulation, with grafting less efficacious than in younger patients. The pediatric patients had double the incidence of granulation tissue compared to adults. The decannulated patients remained asymptomatic at a mean follow-up of 50.5 months. The review of our approach to open airway repair/reconstruction showed its efficacy in advanced-stage laryngotracheal stenosis. Good knowledge of a variety of reconstructive techniques is important to achieve good results in a variety of age groups. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  12. A highly accurate method for monitoring histological recovery in patients with celiac disease on a gluten-free diet using an endoscopic approach that avoids the need for biopsy: a double-center study.

    PubMed

    Cammarota, G; Cuoco, L; Cesaro, P; Santoro, L; Cazzato, A; Montalto, M; La Mura, R; Larocca, L M; Vecchio, F M; Gasbarrini, A; Salvagnini, M; Gasbarrini, G

    2007-01-01

    Endoscopy with duodenal biopsy is often performed in order to assess histological recovery in patients with celiac disease who are on a gluten-free diet. Use of the "immersion" technique during upper endoscopy allows visualization of duodenal villi or detection of total villous atrophy. In this two-center study, we investigated the accuracy of the immersion technique in predicting histological recovery in patients on a gluten-free diet whose initial diagnosis of celiac disease had been made on the basis of total villous atrophy. The immersion technique was performed in 62 patients with celiac disease who were being treated and who had been referred for follow-up (26 patients at the Rome center and 36 patients at the Vicenza center). All these patients had an initial diagnosis based on positive antibodies and biopsy-proved duodenal total villous atrophy. At the follow-up examination, the duodenal villi were re-evaluated as present or absent by one endoscopist at each center, and the results were compared with the histology. At the follow-up endoscopy, the duodenal villi were found to be present in 51 patients and absent in 11. The sensitivity, specificity, positive predictive value, and negative predictive value of the immersion technique for detecting the presence or absence of villi were all 100 %. This study demonstrated the feasibility and the high level of accuracy of the immersion technique in predicting the histological recovery of duodenal villi in patients with celiac disease who are following a gluten-free diet. An endoscopy-based approach that avoids the need for biopsy could be useful for monitoring the dietary adherence and/or response of patients with an initial diagnosis of celiac disease based on total villous atrophy.

  13. Comparing omeprazole with fluoxetine for treatment of patients with heartburn and normal endoscopy who failed once daily proton pump inhibitors: double-blind placebo-controlled trial.

    PubMed

    Ostovaneh, M R; Saeidi, B; Hajifathalian, K; Farrokhi-Khajeh-Pasha, Y; Fotouhi, A; Mirbagheri, S S; Emami, H; Barzin, G; Mirbagheri, S A

    2014-05-01

    Patients with heartburn but without esophageal erosion respond less well to proton pump inhibitors (PPIs). There is a growing body of evidence implicating the role of psychological comorbidities in producing reflux symptoms. Pain modulators improve symptoms in patients with other functional gastrointestinal disorders. We aimed to compare the efficacy of fluoxetine with omeprazole and placebo to achieve symptomatic relief in patients with heartburn and normal endoscopy who failed once daily PPIs. Endoscopy-negative patients with heartburn who failed once daily PPIs were randomly allocated to receive 6 weeks treatment of fluoxetine, omeprazole, or placebo. Random allocation was stratified according to ambulatory pH monitoring study. Percentage of heartburn-free days and symptom severity was assessed. Sixty patients with abnormal and 84 patients with normal pH test were randomized. Subjects receiving fluoxetine experienced more improvement in percentage of heartburn-free days (median 35.7, IQR 21.4-57.1) than those on omeprazole (median 7.14, IQR 0-50, p < 0.001) or placebo (median 7.14, IQR 0-33.6, p < 0.001). In normal pH subgroup, fluoxetine was superior to both omeprazole and placebo regarding percentage of heartburn-free days (median improvement, 57.1, IQR 35.7-57.1 vs 13.9, IQR, 0-45.6 and 7.14, 0-23.8, respectively, p < 0.001), but no significant difference was observed between medications in abnormal pH subgroup. Fluoxetine was superior to omeprazole for improving the symptoms of patients with heartburn and normal endoscopy who failed once daily PPIs. The superiority of fluoxetine was mostly attributed to those with normal esophageal pH rather than those with abnormal pH (ClinicalTrials.gov, number NCT01269788). © 2014 John Wiley & Sons Ltd.

  14. Development of gastrointestinal endoscopy in Malaysia: a historical perspective with special reference to the experience at the University of Malaya Medical Centre.

    PubMed

    Goh, Khean-Lee

    2011-05-01

    Gastrointestinal endoscopy started in the early 1970s in Malaysia with the help of Japanese doctors. It has evolved over the past 30 years. The gastrointestinal endoscopy unit at the University of Malaya Medical Centre has been in the forefront in providing endoscopy services to patients as well as training doctors in endoscopy in the country. In recent years, trainees have included those from neighboring countries in South-East Asia. Among our most significant achievements is the organization of regular international therapeutic endoscopy workshops since 1993 where leading endoscopists from throughout the world have accepted our invitation as teaching faculty. In 2008, the World Organization of Digestive Endoscopy accorded the high distinction of Centre of Excellence to the endoscopy unit of the University of Malaya Medical Centre. © 2011 The Author. Digestive Endoscopy © 2011 Japan Gastroenterological Endoscopy Society.

  15. Design and implementation of fiber-based multiphoton endoscopy with microelectromechanical systems scanning

    PubMed Central

    Tang, Shuo; Jung, Woonggyu; McCormick, Daniel; Xie, Tuqiang; Su, Jiangping; Ahn, Yeh-Chan; Tromberg, Bruce J.; Chen, Zhongping

    2010-01-01

    A multiphoton endoscopy system has been developed using a two-axis microelectromechanical systems (MEMS) mirror and double-cladding photonic crystal fiber (DCPCF). The MEMS mirror has a 2-mm-diam, 20-deg optical scanning angle, and 1.26-kHz and 780-Hz resonance frequencies on the x and y axes. The maximum number of resolvable focal spots of the MEMS scanner is 720×720 on the x and y axes, which indicates that the MEMS scanner can potentially support high-resolution multiphoton imaging. The DCPCF is compared with standard single-mode fiber and hollow-core photonic bandgap fiber on the basis of dispersion, attenuation, and coupling efficiency properties. The DCPCF has high collection efficiency, and its dispersion can be compensated by grating pairs. Three configurations of probe design are investigated, and their imaging quality and field of view are compared. A two-lens configuration with a collimation and a focusing lens provides the optimum imaging performance and packaging flexibility. The endoscope is applied to image fluorescent microspheres and bovine knee joint cartilage. PMID:19566298

  16. Local mediator release after antigen challenge of a bronchial segment in allergic dogs.

    PubMed

    Reiss, T F; Rubinstein, I; Emery, D L; Gold, W M; Boushey, H A

    1989-12-01

    To investigate the local intraluminal bronchial response to an antigenic stimulus, we developed a bronchoscopic double-balloon system to challenge and lavage a segment of the left main-stem bronchus. We studied whether fluid from above or below the occlusion balloons leaked into the bronchial segment. Lavage was performed before and after placement of red and blue pigments proximal and distal to the inflated balloons, respectively, and the recovered lavage fluid was analyzed visually and spectrophotometrically in three experiments. There was no evidence for pigment leakage into the segment. In six anesthetized ragweed-allergic dogs, local ragweed antigen challenges were performed. After balloon inflation in the left main-stem bronchus, we performed two baseline lavages of the interballoon segment, introduced a ragweed antigen solution, and performed two postchallenge lavages. The recovered fluid was analyzed for the concentrations of prostaglandin D2 (PGD2; radioimmunoassay) and histamine (fluorometric technique) and for total and differential cell counts. Antigen challenge was associated with a significant increase in PGD2 concentration in the recovered fluid, rising from a median of 178 pg/ml (range, 157-647) before to 919 pg/ml (range, 149-2,452) after challenge. Median histamine concentrations were 3.1 ng/ml (range, 1-5.4 ng/ml) before and 5.6 ng/ml (range, 1-16.2) after challenge (P = not significant). In four dogs, a control challenge with the antigen vehicle alone showed no change in either mediator. Changes in cell counts after challenge were inconsistent.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Correlations between symptoms, nasal endoscopy, and in-office computed tomography in post-surgical chronic rhinosinusitis patients.

    PubMed

    Ryan, William R; Ramachandra, Tara; Hwang, Peter H

    2011-03-01

    To determine correlations between symptoms, nasal endoscopy findings, and computed tomography (CT) scan findings in post-surgical chronic rhinosinusitis (CRS) patients. Cross-sectional. A total of 51 CRS patients who had undergone endoscopic sinus surgery (ESS) completed symptom questionnaires, underwent endoscopy, and received an in-office sinus CT scan during one clinic visit. For metrics, we used the Sinonasal Outcomes Test-20 (SNOT-20) questionnaire, visual analog symptom scale (VAS), Lund-Kennedy endoscopy scoring scale, and Lund-MacKay (LM) CT scoring scale. We determined Pearson correlation coefficients, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) between scores for symptoms, endoscopy, and CT. The SNOT-20 score and most VAS symptoms had poor correlation coefficients with both endoscopy and CT scores (0.03-0.24). Nasal drainage of pus, nasal congestion, and impaired sense of smell had moderate correlation coefficients with endoscopy and CT (0.24-0.42). Endoscopy had a strong correlation coefficient with CT (0.76). Drainage, edema, and polyps had strong correlation coefficients with CT (0.80, 0.69, and 0.49, respectively). Endoscopy had a PPV of 92.5% and NPV of 45.5% for detecting an abnormal sinus CT (LM score ≥1). In post-ESS CRS patients, most symptoms do not correlate well with either endoscopy or CT findings. Endoscopy and CT scores correlate well. Abnormal endoscopy findings have the ability to confidently rule in the presence of CT opacification, thus validating the importance of endoscopy in clinical decision making. However, a normal endoscopy cannot assure a normal CT. Thus, symptoms, endoscopy, and CT are complementary in the evaluation of the post-ESS CRS patient. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc., Rhinological, and Otological Society, Inc.

  18. Guidelines for designing a digestive disease endoscopy unit: report of the World Endoscopy Organization.

    PubMed

    Mulder, Chris J J; Jacobs, Maarten A J M; Leicester, Roger J; Nageshwar Reddy, D; Shepherd, Libby E A; Axon, Anthony T; Waye, Jerome D

    2013-07-01

    A dedicated digestive disease endoscopy unit is structurally and functionally differentiating rapidly as a result of increasing diagnostic and therapeutic possibilities in the last 10-20 years. Publications with practical details are scarce, imposing a challenge in the construction of such a unit. The lack of authoritative information about endoscopy unit design means that architects produce their own design with or without consulting endoscopists working in such a unit. A working group of the World Endoscopy Organization discussed and outlined a practical approach fordesign and construction of a modern endoscopy unit. Designing the layout is extremely important, necessitating thoughtful planning to provide comfort to the endoscopy staff and patients, and efficient data archiving and transmission during endoscopic services. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  19. Capsule endoscopy: impact on clinical decision making in patients with suspected small bowel bleeding.

    PubMed

    Gubler, C; Fox, M; Hengstler, P; Abraham, D; Eigenmann, F; Bauerfeind, P

    2007-12-01

    Capsule endoscopy is widely used for diagnosis of small-bowel disease; however, the impact of capsule endoscopy on clinical management remains uncertain. We conducted a prospective study of the impact capsule endoscopy on clinical management decisions in 128 patients with suspected small-bowel pathology. Prior to performing each procedure the gastroenterologist predicted the findings of capsule endoscopy and further management based on the clinical history and previous investigations. This prediction was compared with the actual results of capsule endoscopy and the following investigative and therapeutic management. The actual findings of capsule endoscopy and the further management were consistent with clinical prediction in 93/128 patients (73 %) and, irrespective of capsule endoscopy findings, no further procedures were required in 80 % of these patients. In 13 patients (10 %), gastric or colonic pathology was discovered that had not been detected on prior gastroscopy or colonoscopy. Thus, capsule endoscopy findings in the small bowel changed clinical management in 22 patients (17 %). In 4 patients, positive findings on capsule endoscopy that had not been predicted by the examiner prompted referral for abdominal surgery. Conversely, planned surgery was canceled in four other patients. In this series of patients referred for capsule endoscopy, small-bowel findings and appropriate clinical management were predicted on clinical grounds alone in approximately three-quarters of patients. Repetition of standard upper and lower endoscopy may be useful in many patients prior to small-bowel imaging. Referral for capsule endoscopy should take into account whether the findings will impact on clinical management; however, capsule endoscopy is mandatory in patients in whom surgery for small-bowel bleeding is intended.

  20. Crossed-clip strangulation for the management of small intestinal polyps in patients with Peutz-Jeghers syndrome.

    PubMed

    Yano, Tomonori; Shinozaki, Satoshi; Yamamoto, Hironori

    2018-05-19

    Peutz-Jeghers syndrome is an autosomal dominant disorder with multiple hamartomatous polyps throughout the gastrointestinal tract. The clinical history of patients with Peutz-Jeghers syndrome usually includes multiple laparotomies to treat intestinal obstruction caused by polyps. The development of double-balloon enteroscopy enables endoscopic resection of polyps, even in the distal small intestine. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. Capsule endoscopy

    MedlinePlus

    Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...

  2. The setting up and running of a cross-county out-of-hours gastrointestinal bleed service: a possible blueprint for the future.

    PubMed

    Shokouhi, Bahman N; Khan, Mohammad; Carter, Martyn J; Khan, Nasser Q; Mills, Philip; Morris, Danielle; Rowlands, David E; Samsheer, Kote; Sargeant, Ian R; McIntyre, Peter B; Greenfield, Simon M

    2013-07-01

    Acute upper gastrointestinal bleeding (AUGIB) results in 25 000 hospital admissions annually. Patients admitted at weekends with AUGIB have increased mortality, and guidelines advise out-of-hours endoscopy. We present retrospective data from our service involving the interhospital transfer of patients. We pooled resources of two neighbouring general hospitals, just north of London. Emergency endoscopy is performed at the start of the list followed by elective endoscopy in the endoscopy unit on Saturday and Sunday mornings. From Friday evening to Sunday morning, patients admitted to Queen Elizabeth II Hospital (QEII) are medically stabilised and transferred to Lister Hospital by ambulance. 240 endoscopies were performed out of hours from December 2007 to March 2011. Of these, 54 patients were transferred: nine had emergency endoscopy at QEII as they were medically unstable; eight of the patients transferred required therapeutic intervention for active bleeding. The mean pre-endoscopy Rockall score of those transferred was 2.5. We examined the records of 51 of the 54 patients transferred. There were three deaths within 30 days after endoscopy not associated with the transfer process. 19 (37%) patients had reduced hospitalisation after having their endoscopy at the weekend. The introduction of the out-of-hours endoscopy service in our trust has had multiple benefits, including patients consistently receiving timely emergency endoscopy, significantly reduced disruption to emergency operating theatres, and participation of endoscopy nurses ensures a better and safer experience for patients, and better endoscopy decontamination. We suggest our model is safe and feasible for other small units wishing to set up their own out-of-hours endoscopy service to adopt.

  3. The setting up and running of a cross-county out-of-hours gastrointestinal bleed service: a possible blueprint for the future

    PubMed Central

    Shokouhi, Bahman N; Khan, Mohammad; Carter, Martyn J; Khan, Nasser Q; Mills, Philip; Morris, Danielle; Rowlands, David E; Samsheer, Kote; Sargeant, Ian R; McIntyre, Peter B; Greenfield, Simon M

    2013-01-01

    Objective Acute upper gastrointestinal bleeding (AUGIB) results in 25 000 hospital admissions annually. Patients admitted at weekends with AUGIB have increased mortality, and guidelines advise out-of-hours endoscopy. We present retrospective data from our service involving the interhospital transfer of patients. Design We pooled resources of two neighbouring general hospitals, just north of London. Emergency endoscopy is performed at the start of the list followed by elective endoscopy in the endoscopy unit on Saturday and Sunday mornings. From Friday evening to Sunday morning, patients admitted to Queen Elizabeth II Hospital (QEII) are medically stabilised and transferred to Lister Hospital by ambulance. Results 240 endoscopies were performed out of hours from December 2007 to March 2011. Of these, 54 patients were transferred: nine had emergency endoscopy at QEII as they were medically unstable; eight of the patients transferred required therapeutic intervention for active bleeding. The mean pre-endoscopy Rockall score of those transferred was 2.5. We examined the records of 51 of the 54 patients transferred. There were three deaths within 30 days after endoscopy not associated with the transfer process. 19 (37%) patients had reduced hospitalisation after having their endoscopy at the weekend. Conclusions The introduction of the out-of-hours endoscopy service in our trust has had multiple benefits, including patients consistently receiving timely emergency endoscopy, significantly reduced disruption to emergency operating theatres, and participation of endoscopy nurses ensures a better and safer experience for patients, and better endoscopy decontamination. We suggest our model is safe and feasible for other small units wishing to set up their own out-of-hours endoscopy service to adopt. PMID:28839729

  4. Comparison of Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Using Ethanolamine Oleate (EO), BRTO Using Sodium Tetradecyl Sulfate (STS) Foam and Vascular Plug-Assisted Retrograde Transvenous Obliteration (PARTO)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Young Hwan; Kim, Young Hwan, E-mail: yhkim68@dsmc.or.kr; Kim, Chan Sun

    PurposeTo compare the clinical outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) using ethanolamine oleate (EO), BRTO using sodium tetradecyl sulfate (STS) foam, and vascular plug-assisted retrograde transvenous obliteration (PARTO).Materials and MethodsFrom April 2004 to February 2015, ninety-five patients underwent retrograde transvenous obliteration for gastric varices were analyzed retrospectively. BRTO with EO was performed in 49 patients, BRTO with STS foam in 25, and PARTO in 21. Among them, we obtained follow-up data in 70 patients. Recurrence of gastric varices was evaluated by follow-up endoscopy or CT. Medical records were reviewed for the clinical efficacy. Statistical analyses were performed by Kaplan–Meiermore » method, Chi-square, Fisher’s, and Kruskal–Wallis tests.ResultsTechnical and clinical success was 94.7 %. As major complications, a hemoglobinuria and a death due to disseminated intravascular coagulation (DIC) were occurred in two patients with BRTO using EO. Recurrence occurred more frequently in PARTO group (P < 0.05). Recurrence occurred in three patients in BRTO using EO group and four patients in PARTO group with 3.2 and 32.8 % of each expected 1-year recurrence rates. There was no recurrence in BRTO using STS group. Abdominal pain occurred more frequently in BRTO using EO than BRTO using STS foam and PARTO (P < 0.05). Procedure time of PARTO was shorter than two conventional BRTOs (P < 0.05).ConclusionsBRTO using STS foam or PARTO is better than BRTO using EO for treatment of gastric varices in terms of complication or procedure time. However, PARTO showed frequent recurrence of gastric varices during the long-term follow-up rather than BRTO.« less

  5. Systematic review and meta-analysis of single-balloon enteroscopy-assisted ERCP in patients with surgically altered GI anatomy.

    PubMed

    Inamdar, Sumant; Slattery, Eoin; Sejpal, Divyesh V; Miller, Larry S; Pleskow, Douglas K; Berzin, Tyler M; Trindade, Arvind J

    2015-07-01

    Surgically altered pancreaticobiliary anatomy increases the difficulty of performing ERCP. Single-balloon enteroscopy (SBE) is a relatively new technique that can be used for ERCP in patients with surgically altered anatomy. To evaluate the therapeutic and diagnostic success of SBE-ERCP among patients with surgically altered anatomy. Systematic review and meta-analysis of studies involving SBE-ERCP in patients with Roux-en-Y gastric bypass, hepaticojejunostomy, or Whipple procedure. Enteroscopy success was defined as success in reaching the papilla and/or biliary anastomosis by using SBE. Diagnostic success was defined as obtaining a cholangiogram. Procedural success was defined as the ability to provide successful intervention, if appropriate. A random-effects model was used. A total of 461 patients underwent SBE-ERCP from 15 trials. The pooled enteroscopy, diagnostic, and procedural success rates were 80.9% (95% confidence interval [CI], 75.3%-86.4%), 69.4% (95% CI, 61.0%-77.9%), and 61.7% (95% CI, 52.9%-70.5%), respectively. There was statistical large heterogeneity for enteroscopy, diagnostic, and therapeutic success (P < .001 for all). Adverse events occurred in 6.5% (95% CI, 4.7%-9.1%) of patients. There was no evidence of publication bias in this meta-analysis. Our findings and interpretations are limited by the quantity and heterogeneity of the studies included in the analysis. SBE-ERCP has high diagnostic and procedural success rates in this challenging patient population. It should be considered a first-line intervention when biliary access is required after Roux-en-Y gastric bypass, hepaticojejunostomy, or Whipple procedure. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  6. Endoscopic findings and treatment outcome in cases presenting with dysphagia.

    PubMed

    Hafeez, Muhammad; Salamat, Amjad; Saeed, Farrukh; Zafar, Hafiz; Hassan, Fayyaz; Farooq, Asif

    2011-01-01

    Dysphagia results from impeded transport of liquids, solids, or both from the pharynx to the stomach. Among the malignant lesions, carcinoma of oesophagus is the commonest cause. Our objective was to find out the frequency of different endoscopic lesions and outcome of the endoscopic therapeutic interventions in patients presenting with dysphagia. This descriptive study was conducted at Department of Gastroenterology, Military Hospital Rawalpindi from June 2008 to May 2009. Patients of dysphagia after their consent were interviewed about the symptoms. Relevant biochemical investigations were done. Barium swallow and upper Gastrointestinal (GI) Endoscopy were carried out. Benign strictures were dilated with Savary Gilliard Dilators. Malignant strictures were further evaluated to decide treatment plan. In patients considered to have oesophageal dysmotility, pressure manometery was done before specific therapy. Seventy nine patients were enrolled. Twenty-five had malignant strictures, out of those commonest was adenocarcinoma 14 (56%). Twenty-nine had benign strictures the commonest being Gastro-oesophageal Reflux Disease (GERD) related peptic stricture 9 (31%). Fifteen had oesophageal dysmotility, and achalasia was present in 10 out of them. After evaluation 12 out of 25 patients with malignant strictures were considered fit for surgery. Self-expanding metal stents (SEMS) were passed in 5. All benign strictures were dilated with Savary-Gillard dilators. Pneumatic balloon dilation was done in patients of achalasia. The commonest malignant lesion resulting in dysphagia was adenocarcinoma while in benign it was GERD related peptic stricture. Achalasia was most frequent in oesophageal motility disorders. Standard of treatment for early oesophageal malignancy is surgical resection. SEMS is a reliable way to allay dysphagia in inoperable cases. Savary Gillard dilatation in benign, and pneumatic balloon achalasia dilatations are effective ways of treatment.

  7. Long-term outcomes and risk factors of biliary stent dysfunction after endoscopic double stenting for malignant biliary and duodenal obstructions.

    PubMed

    Matsumoto, Kazuyuki; Kato, Hironari; Tsutsumi, Koichiro; Mizukawa, Sho; Yabe, Syuntaro; Seki, Hiroyuki; Akimoto, Yutaka; Uchida, Daisuke; Tomoda, Takeshi; Yamamoto, Naoki; Horiguchi, Shigeru; Kuwaki, Kenji; Okada, Hiroyuki

    2017-07-01

    Few reports describe the endoscopic double-stenting procedure for malignant biliary and duodenal obstructions. We evaluated the clinical outcomes from double stenting, and analyzed the risk factors for biliary stent dysfunction following double stenting. Eighty-one patients who underwent endoscopic double stenting for malignant biliary and duodenal obstructions were retrospectively analyzed. We determined the stent dysfunction rate and the biliary stent dysfunction risk factors, and analyzed the endoscopic reintervention results. Overall survival time and survival time following double stenting were 365 (38-1673) days and 73 (20-954) days, respectively. After double stenting, the 3-month and 6-month duodenal stent dysfunction rates were 14% and 41%, respectively. Reintervention technical success rate was 100% (10/10), and mean gastric outlet obstruction scoring system scores improved from 0.7 to 2.4 points (P < 0.001). The 3-month and 6-month biliary stent dysfunction rates were 26% and 41%, respectively. The reintervention technical and clinical success rates were 95% (20/21) and 81% (17/21), respectively. Risk factors for biliary stent dysfunction following double stenting were events associated with duodenal stent dysfunction (odds ratio [OR], 11.1; 95% confidence interval [CI], 2.09-87.4; P = 0.0044) and the biliary stent end's location (OR, 6.93; 95% CI, 1.37-40.2; P = 0.0019). Some patients had stent dysfunction irrespective of the survival period after double stenting. Endoscopic reintervention was technically feasible and clinically effective even after double stenting. Duodenal stent dysfunction and biliary stent end's location were risk factors for biliary stent dysfunction. © 2017 Japan Gastroenterological Endoscopy Society.

  8. Optimizing efficiency and operations at a California safety-net endoscopy center: a modeling and simulation approach.

    PubMed

    Day, Lukejohn W; Belson, David; Dessouky, Maged; Hawkins, Caitlin; Hogan, Michael

    2014-11-01

    Improvements in endoscopy center efficiency are needed, but scant data are available. To identify opportunities to improve patient throughput while balancing resource use and patient wait times in a safety-net endoscopy center. Safety-net endoscopy center. Outpatients undergoing endoscopy. A time and motion study was performed and a discrete event simulation model constructed to evaluate multiple scenarios aimed at improving endoscopy center efficiency. Procedure volume and patient wait time. Data were collected on 278 patients. Time and motion study revealed that 53.8 procedures were performed per week, with patients spending 2.3 hours at the endoscopy center. By using discrete event simulation modeling, a number of proposed changes to the endoscopy center were assessed. Decreasing scheduled endoscopy appointment times from 60 to 45 minutes led to a 26.4% increase in the number of procedures performed per week, but also increased patient wait time. Increasing the number of endoscopists by 1 each half day resulted in increased procedure volume, but there was a concomitant increase in patient wait time and nurse utilization exceeding capacity. By combining several proposed scenarios together in the simulation model, the greatest improvement in performance metrics was created by moving patient endoscopy appointments from the afternoon to the morning. In this simulation at 45- and 40-minute appointment times, procedure volume increased by 30.5% and 52.0% and patient time spent in the endoscopy center decreased by 17.4% and 13.0%, respectively. The predictions of the simulation model were found to be accurate when compared with actual changes implemented in the endoscopy center. Findings may not be generalizable to non-safety-net endoscopy centers. The combination of minor, cost-effective changes such as reducing appointment times, minimizing and standardizing recovery time, and making small increases in preprocedure ancillary staff maximized endoscopy center efficiency across a number of performance metrics. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  9. Endoscopy: MedlinePlus Health Topic

    MedlinePlus

    ... What Is Endoscopy? (American Cancer Society) Also in Spanish Related Issues Ensuring the Safety of Your Endoscopic Procedure (American Society for Gastrointestinal Endoscopy) Also in Spanish Sedation for Your Endoscopy (American College of Gastroenterology) ...

  10. Less Is More: A Minimalist Approach to Endoscopy.

    PubMed

    Shaheen, Nicholas J; Fennerty, M Brian; Bergman, Jacques J

    2018-05-01

    A substantial literature documents inappropriate usage of gastrointestinal endoscopy in a variety of clinical settings. Overusage of endoscopy appears to be common, and 30% or more of procedures performed in some clinical settings have questionable indications. The potential reasons for overuse of endoscopy are multiple, and include cancer phobia, fear of medical malpractice litigation, profit motive, the investigation of "incidentalomas" found on other imaging, and underappreciation of the delayed harms of endoscopy, among other reasons. Clinical guidelines, which should limit overuse of endoscopy, may instead serve to promote it, if authors opt to be "conservative," recommending endoscopy in situations of unclear utility. Several strategies may decrease overuse of endoscopy, including careful attention to risk stratification when choosing patients to screen, adherence to guidelines for surveillance intervals for colonoscopy, the use of quality indicators to identify outliers in endoscopy utilization, and education on appropriate indications and the risks of overuse at the medical student, residency, and fellowship levels. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  11. Towards combined optical coherence tomography and hyper-spectral imaging for gastrointestinal endoscopy

    NASA Astrophysics Data System (ADS)

    Attendu, Xavier; Crunelle, Camille; de Sivry-Houle, Martin Poinsinet; Maubois, Billie; Urbain, Joanie; Turrell, Chloe; Strupler, Mathias; Godbout, Nicolas; Boudoux, Caroline

    2018-04-01

    Previous works have demonstrated feasibility of combining optical coherence tomography (OCT) and hyper-spectral imaging (HSI) through a single double-clad fiber (DCF). In this proceeding we present the continued development of a system combining both modalities and capable of rapid imaging. We discuss the development of a rapidly scanning, dual-band, polygonal swept-source system which combines NIR (1260-1340 nm) and visible (450-800 nm) wavelengths. The NIR band is used for OCT imaging while visible light allows HSI. Scanning rates up to 24 kHz are reported. Furthermore, we present and discuss the fiber system used for light transport, delivery and collection, and the custom signal acquisition software. Key points include the use of a double-clad fiber coupler as well as important alignments and back-reflection management. Simultaneous and co-registered imaging with both modalities is presented in a bench-top system

  12. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    PubMed

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  13. Steroid-refractory extensive enteritis complicated by ulcerative colitis successfully treated with adalimumab

    PubMed Central

    Okabayashi, Shinji; Sujino, Tomohisa; Ozaki, Ryo; Umeda, Satoko; Toyonaga, Takahiko; Saito, Eiko; Nakano, Masaru; Tablante, Maria Carla; Morinaga, Shojiroh; Hibi, Toshifumi

    2017-01-01

    Extracolonic involvement of the gastrointestinal tract is extremely uncommon in ulcerative colitis (UC) and rarely found in the upper gastrointestinal tract or in postoperative cases since it typically responds to steroids. Here we report a case of UC complicated by extensive ileal inflammation that was refractory to steroids. A 20-year-old man was diagnosed with UC of typical pancolitis without ileal involvement and started treatment with pH-dependent mesalazine and oral prednisolone. Although his symptoms transiently resolved, the condition flared when the steroid dose was tapered down. Computed tomography revealed marked thickening of the ileal wall, and capsule endoscopy and balloon-assisted enteroscopy found diffuse mucosal inflammation with ulcers in the ileum. On the contrary, the inflammation in the colon and rectum was improving. Since the response to the second steroid course was inadequate, treatment with adalimumab and 6-mercaptopurine was initiated and finally achieved clinical and endoscopic remission. The investigation of small intestinal lesions is necessary in patients with UC whose clinical deterioration cannot be explained by colonic lesions. PMID:29142523

  14. [Foreign Body in Esophagus].

    PubMed

    Domeki, Yasushi; Kato, Hiroyuki

    2015-07-01

    An esophageal foreign body is the term for a foreign body in the esophagus. The 2 age groups most prone to this condition are children age 9 and under (and especially toddlers age 4 and under) and elderly individuals age 70 and over. A foreign body often lodges where the esophagus is most constricted. In toddlers, the foreign body is often currency or coins or a toy. In adults, the body is often a piece of fish, dentures, a piece of meat, a pin or needle, or a drug in its blister pack packaging. In children, an esophageal foreign body is treated by fluoroscopically guided removal of the body with a balloon catheter or magnetic catheter or removal of the body via endoscopy or direct esophagoscopy under general anesthesia. In adults, the best choice for treating an esophageal foreign body is removing the body with an endoscope but there are instances where surgery is performed because the body is hard to remove endoscopically, a puncture has occurred, or empyema or mediastinitis has developed. This paper reviews the diagnosis and treatment of an esophageal foreign body.

  15. Focal achalasia – case report and review of the literature

    PubMed Central

    TUTUIAN, RADU

    2018-01-01

    Esophageal achalasia is a primary smooth muscle motility disorder specified by aperistalsis of the tubular esophagus in combination with a poorly relaxing and occasionally hypertensive lower esophageal sphincter (LES). These changes occur secondary to the destruction of the neural network coordinating esophageal peristalsis and LES relaxation (plexus myentericus). There are limited data on segmental involvement of the esophagus in adults. We report on the case of a 54-year-old man who presented initially with complete aperistalsis limited to the distal esophagus. After a primary good response to BoTox-infiltration of the distal esophagus the patient relapsed two years later. The manometric recordings documented now a progression of the disease with a poorly relaxing hypertensive lower esophageal sphincter and complete aperistalsis of the tubular esophagus (type III achalasia according to the Chicago 3.0 classification system). This paper also reviews diagnostic findings (including high resolution manometry, CT scan, barium esophagram, upper endoscopy and upper endoscopic ultrasound data) in patients with achalasia and summarizes the therapeutic options (including pneumatic balloon dilatation, botulinum toxin injection, surgical or endoscopic myotomy). PMID:29440962

  16. Diagnosis and treatment of superficial esophageal cancer

    PubMed Central

    Barret, Maximilien; Prat, Frédéric

    2018-01-01

    Endoscopy allows for the screening, early diagnosis, treatment and follow up of superficial esophageal cancer. Endoscopic submucosal dissection has become the gold standard for the resection of superficial squamous cell neoplasia. Combinations of endoscopic mucosal resection and radiofrequency ablation are the mainstay of the management of Barrett’s associated neoplasia. However, protruded, non-lifting or large lesions may be better managed by endoscopic submucosal dissection. Novel ablation tools, such as argon plasma coagulation with submucosal lifting and cryoablation balloons, are being developed for the treatment of residual Barrett’s esophagus, since iatrogenic strictures still hamper the development of extensive circumferential resections in the esophagus. Optimal surveillance modalities after endoscopic resection are still to be determined. The assessment of the risk of lymph-node metastases, as well as of the need for additional treatments based on qualitative and quantitative histological criteria, balanced to the patient’s condition, requires a dedicated multidisciplinary team decision process. The need for trained endoscopists, expert pathologists and surgeons, and specialized multidisciplinary meetings underlines the role of expert centers in the management of superficial esophageal cancer. PMID:29720850

  17. Bioresorbable vascular scaffolds for LMCA with double vessel disease under IVUS guidance.

    PubMed

    Kasturi, Sridhar; Vilvanathan, Vinoth Kumar

    2015-12-01

    An 80-year-old male patient, presented with chest pain. ECG showed ST elevation in leads V2 to V4 and T wave inversion in leads V2-V6. Check angiogram revealed ostial LMCA 70% lesion & mid-LAD 90% lesion and LCX proximal 80% lesion. Predilatation of LMCA lesion was done with 2.0 × 12 mm NC Trek balloon and the LAD lesion with 2.0 × 12 mm and 2.5 × 08 mm (NC Trek balloons). Prestenting IVUS (Intravascular ultrasound) was done with Atlantis SR pro 40 MHz 3.6 Fr catheter. IVUS showed the LAD to have a minimal lumen area of 2.6 sq mm with 90% fibrotic plaque and a vessel size of 2.5mm and the LMCA to have a minimal lumen area of 8.8 sq mm with 70% fibrotic plaque and vessel size of 3.8mm. Mid-LAD stenting was done with 2.5 × 28 mm Absorb Stent (BVS). Predilatation of LCX lesion was done with 2.5 × 08 mm NC Trek balloon. Then stenting was performed with 3.0 × 28 mm Absorb Stent (BVS). Check angiogram showed edge dissection proximal to the BVS Stent which was covered with 3.0 × 12 mm Xience Xpedtion Stent (DES). Then LMCA Stenting was done with 3.5 × 12 mm Absorb Stent. Post dilatation was done with 4.0 × 08 mm NC Trek balloon. Post Stenting LMCA - LAD IVUS was done. LMCA and LAD Stents were well opposed without any dissection or residual stenosis. TIMI III Flow was achieved in the final results. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  18. Reporting trends and outcomes in ST-segment-elevation myocardial infarction national hospital quality assessment programs.

    PubMed

    McCabe, James M; Kennedy, Kevin F; Eisenhauer, Andrew C; Waldman, Howard M; Mort, Elizabeth A; Pomerantsev, Eugene; Resnic, Frederic S; Yeh, Robert W

    2014-01-14

    For patients who undergo primary percutaneous coronary intervention (PCI) for ST-segment-elevation myocardial infarction, the door-to-balloon time is an important performance measure reported to the Centers for Medicare & Medicaid Services (CMS) and tied to hospital quality assessment and reimbursement. We sought to assess the use and impact of exclusion criteria associated with the CMS measure of door-to-balloon time in primary PCI. All primary PCI-eligible patients at 3 Massachusetts hospitals (Brigham and Women's, Massachusetts General, and North Shore Medical Center) were evaluated for CMS reporting status. Rates of CMS reporting exclusion were the primary end points of interest. Key secondary end points were between-group differences in patient characteristics, door-to-balloon times, and 1-year mortality rates. From 2005 to 2011, 26% (408) of the 1548 primary PCI cases were excluded from CMS reporting. This percentage increased over the study period from 13.9% in 2005 to 36.7% in the first 3 quarters of 2011 (P<0.001). The most frequent cause of exclusion was for a diagnostic dilemma such as a nondiagnostic initial ECG, accounting for 31.2% of excluded patients. Although 95% of CMS-reported cases met door-to-balloon time goals in 2011, this was true of only 61% of CMS-excluded cases and consequently 82.6% of all primary PCI cases performed that year. The 1-year mortality for CMS-excluded patients was double that of CMS-included patients (13.5% versus 6.6%; P<0.001). More than a quarter of patients who underwent primary PCI were excluded from hospital quality reports collected by CMS, and this percentage has grown substantially over time. These findings may have significant implications for our understanding of process improvement in primary PCI and mechanisms for reimbursement through Medicare.

  19. The effect of upper gastrointestinal system endoscopy process on serum oxidative stress levels.

    PubMed

    Turan, Mehmet Nuri; Aslan, Mehmet; Bolukbas, Filiz Fusun; Bolukbas, Cengiz; Selek, Sahbettin; Sabuncu, Tevfik

    2016-12-01

    Some authors have investigated the effects of oxidative stress in some process such as undergoing laparoscopic. However, the effect of upper gastrointestinal system endoscopy process on oxidative stress is unclear. We evaluated the short-term effect of upper gastrointestinal system endoscopy process on oxidative stress. Thirty patients who underwent endoscopy process and 20 healthy controls were enrolled in the prospective study. Serum total antioxidant capacity and total oxidant status measurements were measured before and after endoscopy process. The ratio percentage of total oxidant status to total antioxidant capacity was regarded as oxidative stress index. Before endoscopy process, serum total antioxidant capacity levels were higher, while serum total oxidant status levels and oxidative stress index values were lower in patients than controls, but this difference was not statistically significant (all, p > 0.05). After endoscopy process, serum total antioxidant capacity and total oxidant status levels were significantly higher in patients than before endoscopy process (both, p < 0.05). However, oxidative stress index values were slight higher in patients but this difference was not statistically significant (p > 0.05). We observed that serum TAC and TOS levels were increased in patients who underwent endoscopy process after endoscopy process. However, short-time upper gastrointestinal system endoscopy process did not cause an important change in the oxidative stress index. Further studies enrolling a larger number of patients are required to clarify the results obtained here.

  20. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.

    PubMed

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-08-01

    At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.

  1. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo

    PubMed Central

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2013-01-01

    Presently, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures which provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high resolution images, it is also safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically-specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically-relevant depths, ideal for soft tissue imaging. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, enabling multi-modality imaging with complementary contrast. Here, we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and demonstrate its ability to image internal organs in vivo, illustrating its potential clinical application. PMID:22797808

  2. Efficiency of upper gastrointestinal endoscopy in pediatric surgical practice

    PubMed Central

    Temiz, Abdulkerim

    2015-01-01

    After the introduction of flexible fiber optic endoscopy to pediatric gastroenterology in the 1970s, upper gastrointestinal (UGI) endoscopy can be performed for the diagnosis and treatment of all age groups of children. We review indications, contraindications, preparation of patients for the procedure, and details of diagnostic and therapeutic UGI endoscopy used in pediatric surgery. We also discuss potential complications of endoscopy. PMID:26566483

  3. Delayed bleeding and hemorrhage of mucosal defects after gastric endoscopic submucosal dissection on second-look endoscopy.

    PubMed

    Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya

    2016-04-01

    Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p < 0.05). Complication of a histological ulcer, large size of the resected specimen and long ESD procedure time were shown to be risk factors for hemorrhage of mucosal defects after ESD on second-look endoscopy by univariate analysis. Multivariate analysis indicated that only large size of the resected specimen was a risk factor. In a specimen size of >35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.

  4. [Interventional radiology in treatment of biliodigestive anastomoses strictures].

    PubMed

    Okhotnikov, O I; Yakovleva, M V; Grigoriev, S N

    2016-01-01

    To analyze efficacy of interventional methods via antegrade transhepatic approach in treatment of patients with strictures of biliodigestive anastomoses. 24 patients aged 47.2 years were treated for the period 2002-2015. Average time from extrahepatic biliary reconstruction using transhepatic stented tubes to strictures appearance varied from 9 months to 12 years. One- and double-sided percutaneous transhepatic cholangiostomy was performed to abort biliary hypertension. Stricture recanalization was achieved using «catheter-wire» system. Antegrade dilatation of stricture was made using balloon catheter 8 mm and pressure up to 6 atm and stage exposition up to 10 minutes. Balloon repair of anastomosis was supplemented by stented outer-inner drainage of the area of stricture. Restoration of patency of stricture area using antegrade interventional methods was effective in 22 patients. Recurrent stricture occurred in 2 cases within 1.5 years that required repeated biliary reconstruction including antegrade extraction of blocked uncovered stent in 1 patient. There were no major postoperative complications and deaths. Maximal recurrence-free follow-up after stent installation was 11 years.

  5. Lubiprostone improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled 2-way crossover study.

    PubMed

    Matsuura, Mizue; Inamori, Masahiko; Inou, Yumi; Kanoshima, Kenji; Higurashi, Takuma; Ohkubo, Hidenori; Iida, Hiroshi; Endo, Hiroki; Nonaka, Takashi; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi

    2017-06-01

     Lubiprostone has been reported to be an anti-constipation drug. The aim of the study was to investigate the usefulness of lubiprostone both for bowel preparation and as a propulsive agent in small bowel endoscopy.  This was a double-blind, placebo-controlled, 2-way crossover study of subjects who volunteered to undergo capsule endoscopy (CE). A total of 20 subjects (16 male and 4 female volunteers) were randomly assigned to receive a 24-μg tablet of lubiprostone 120 minutes prior to capsule ingestion for CE (L regimen), or a placebo tablet 120 minutes prior to capsule ingestion for CE (P regimen). Main outcome was gastric transit time (GTT) and small-bowel transit time (SBTT). Secondary outcome was adequacy of small-bowel cleansing and the fluid score in the small bowel. The quality of the capsule endoscopic images and fluid in the small bowel were assessed on 5-point scale.  The capsule passed into the small bowel in all cases. Median GTT was 57.3 (3 - 221) minutes for the P regimen and 61.3 (10 - 218) minutes for the L regimen ( P  = 0.836). Median SBTT was 245.0 (164 - 353) minutes for the P regimen and 228.05 (116 - 502) minutes for the L regimen ( P  = 0.501). The image quality score in the small bowel was 3.05 ± 1.08 for the P regimen and 3.80 ± 0.49 for the L regimen ( P  < 0.001). The fluid score in the small bowel was 2.04 ± 1.58 for the P regimen and 2.72 ± 1.43 for the L regimen ( P  < 0.001). There was a significant difference between the 2 regimens with regard to image quality. The fluid score was more plentiful for the L regimen than for the P regimen. There were no cases of capsule retention or serious adverse events in this study.  Our study showed that use of lubiprostone prior to CE significantly improved visualization of the small bowel during CE as a result of inducing fluid secretion into the small bowel.

  6. WEO position statement on hygiene in digestive endoscopy: Focus on endoscopy units in Asia and the Middle East.

    PubMed

    Murdani, Abdullah; Kumar, Ajay; Chiu, Han-Mo; Goh, Khean-Lee; Jang, Byung Ik; Khor, Christopher J L; Lau, James; Mostafa, Ibrahim; Ramchandani, Mohan; Ratanalert, Siriporn; Tajiri, Hisao; Yuen, Minghwa; Zhang, Shu Tian; Duforest-Rey, Dianelle; Rey, Jean-Francois

    2017-01-01

    The aim of this position statement is to reinforce the key points of hygiene in digestive endoscopy. The present article details the minimum hygiene requirements for reprocessing of endoscopes and endoscopic devices, regardless of the reprocessing method (automated washer-disinfector or manual cleaning) and the endoscopy setting (endoscopy suite, operating room, elective or emergency procedures). These minimum requirements are mandatory for patient safety. Both advanced diagnostic and therapeutic endoscopies should be carried out in an environment that is safe for patients and staff. Particular attention is given to contaminants. Procedural errors in decontamination, defective equipment, and failure to follow disinfection guidelines are major factors contributing to transmission of infection during endoscopy. Other important risk factors include inadequate cleaning, use of older endoscopes with surface and working channel irregularities, and contamination of water bottles or irrigating solutions. Infections by multidrug-resistant organisms have become an increasing problem in health-care systems worldwide. Since 2010, outbreaks of multidrug-resistant bacteria associated with endoscopic retrograde cholangiopancreatography have been reported from the USA, France, Germany, and The Netherlands. In many endoscopy units in Asia and the Middle East, reprocessing procedures have lagged behind those of Western countries for cultural reasons or lack of financial resources. This inconsistency in standards is now being addressed, and the World Endoscopy Organization has prepared this position statement to highlight key points for quality assurance in any endoscopy unit in any country. © 2016 Japan Gastroenterological Endoscopy Society.

  7. Management of Suspicious Mucosa-Associated Lymphoid Tissue Lymphoma in Gastric Biopsy Specimens Obtained during Screening Endoscopy.

    PubMed

    Yang, Hyo-Joon; Lim, Seon Hee; Lee, Changhyun; Choi, Ji Min; Yang, Jong In; Chung, Su Jin; Choi, Seung Ho; Im, Jong Pil; Kim, Sang Gyun; Kim, Joo Sung

    2016-07-01

    It is often difficult to differentiate gastric mucosa-associated lymphoid tissue (MALT) lymphoma from Helicobacter pylori-associated follicular gastritis, and thus, it becomes unclear how to manage these diseases. This study aimed to explore the management strategy for and the long-term outcomes of suspicious gastric MALT lymphoma detected by forceps biopsy during screening upper endoscopy. Between October 2003 and May 2013, consecutive subjects who were diagnosed with suspicious gastric MALT lymphomas by screening endoscopy in a health checkup program in Korea were retrospectively enrolled. Suspicious MALT lymphoma was defined as a Wotherspoon score of 3 or 4 upon pathological evaluation of the biopsy specimen. Of 105,164 subjects who underwent screening endoscopies, 49 patients with suspicious MALT lymphomas who underwent subsequent endoscopy were enrolled. Eight patients received a subsequent endoscopy without H. pylori eradication (subsequent endoscopy only group), and 41 patients received H. pylori eradication first followed by endoscopy (eradication first group). MALT lymphoma development was significantly lower in the eradication first group (2/41, 4.9%) than in the subsequent endoscopy only group (3/8, 37.5%, P = 0.026). Notably, among 35 patients with successful H. pylori eradication, there was only one MALT lymphoma patient (2.9%) in whom complete remission was achieved, and there was no recurrence during a median 45 months of endoscopic follow-up. H. pylori eradication with subsequent endoscopy would be a practical management option for suspicious MALT lymphoma detected in a forceps biopsy specimen obtained during screening upper endoscopy.

  8. Does ear endoscopy provide advantages in the outpatient management of open mastoidectomy cavities?

    PubMed

    Freire, Gustavo Subtil Magalhães; Sampaio, Andre Luiz Lopes; Lopes, Rafaela Aquino Fernandes; Nakanishi, Márcio; de Oliveira, Carlos Augusto Costa Pires

    2018-01-01

    To evaluate the use of ear endoscopy in the postoperative management of open mastoidectomy cavities, and to test whether ear endoscopy improves inspection and cleaning compared with ear microscopy. Prospective study. Thirty-two ears were divided into two groups: group 1, examination and cleaning of mastoid cavities under endoscopic visualization after microscopic standard ear cleaning; group 2, examination and cleaning of mastoid cavities under microscopic visualization after endoscope-assisted ear cleaning. We assessed the ability of each method to provide exposure and facilitate cleaning, comparing the benefits of microscopy and endoscopy when used sequentially and vice-versa. Endoscopy provided additional benefits for exposure in 61.1% of cases and cleaning in 66.7%. Microscopy provided no additional benefits in terms of exposure in any case, and provided added benefit for cleaning in only 21.4% of cases. For outpatient postoperative care of open mastoidectomy cavities, ear endoscopy provides greater benefit over ear microscopy than vice-versa. In over half of all cases, endoscopy was able to expose areas not visualized under the microscope. Furthermore, in two-thirds of cases, endoscopy enabled removal of material that could not be cleared under microscopy. Ear endoscopy was superior to microscopy in terms of enabling exposure and cleaning of hard-to-reach sites, due to its wider field of vision. Ear endoscopy is a feasible technique for the postoperative management of open mastoidectomy cavities. Ear endoscopy provided superior advantages in terms of exposure and aural cleaning compared with microscopy.

  9. Endoscopy in Canada: Proceedings of the National Roundtable

    PubMed Central

    Switzer, Noah; Dixon, Elijah; Tinmouth, Jill; Bradley, Nori; Vassiliou, Melina; Schwaitzberg, Steve; Gomes, Anthony; Ellsmere, James; de Gara, Chris

    2015-01-01

    This 2014 roundtable discussion, hosted by the Canadian Association of General Surgeons, brought together general surgeons and gastroenterologists with expertise in endoscopy from across Canada to discuss the state of endoscopy in Canada. The focus of the roundtable was the evaluation of the competence of general surgeons at endoscopy, reviewing quality assurance parameters for high-quality endoscopy, measuring and assessing surgical resident preparedness for endoscopy practice, evaluating credentialing programs for the endosuite and predicting the future of endoscopic services in Canada. The roundtable noted several important observations. There exist inadequacies in both resident training and the assessment of competency in endoscopy. From these observations, several collaborative recommendations were then stated. These included the need for a formal and standardized system of both accreditation and training endoscopists. PMID:25886520

  10. Virtual endoscopic imaging of the spine.

    PubMed

    Kotani, Toshiaki; Nagaya, Shigeyuki; Sonoda, Masaru; Akazawa, Tsutomu; Lumawig, Jose Miguel T; Nemoto, Tetsuharu; Koshi, Takana; Kamiya, Koshiro; Hirosawa, Naoya; Minami, Shohei

    2012-05-20

    Prospective trial of virtual endoscopy in spinal surgery. To investigate the utility of virtual endoscopy of the spine in conjunction with spinal surgery. Several studies have described clinical applications of virtual endoscopy to visualize the inside of the bronchi, paranasal sinus, stomach, small intestine, pancreatic duct, and bile duct, but, to date, no study has described the use of virtual endoscopy in the spine. Virtual endoscopy is a realistic 3-dimensional intraluminal simulation of tubular structures that is generated by postprocessing of computed tomographic data sets. Five patients with spinal disease were selected: 2 patients with degenerative disease, 2 patients with spinal deformity, and 1 patient with spinal injury. Virtual endoscopy software allows an observer to explore the spinal canal with a mouse, using multislice computed tomographic data. Our study found that virtual endoscopy of the spine has advantages compared with standard imaging methods because surgeons can noninvasively explore the spinal canal in all directions. Virtual endoscopy of the spine may be useful to surgeons for diagnosis, preoperative planning, and postoperative assessment by obviating the need to mentally construct a 3-dimensional picture of the spinal canal from 2-dimensional computed tomographic scans.

  11. Clinical trial: a randomized trial of early endoscopy, Helicobacter pylori testing and empirical therapy for the management of dyspepsia in primary care.

    PubMed

    Duggan, A E; Elliott, C A; Miller, P; Hawkey, C J; Logan, R F A

    2009-01-01

    Early endoscopy, Helicobacter pylori eradication and empirical acid suppression are commonly used dyspepsia management strategies in primary care but have not been directly compared in a single trial. To compare endoscopy, H. pylori test and refer, H. pylori test and treat and empirical acid suppression for dyspepsia in primary care. Patients presenting to their general practitioner with dyspepsia were randomized to endoscopy, H. pylori'test and treat', H. pylori test and endoscope positives, or empirical therapy with symptoms, patient satisfaction, healthcare costs and cost effectiveness at 12 months being the outcomes. At 2 months, the proportion of patients reporting no or minimal dyspeptic symptoms ranged from 74% for those having early endoscopy to 55% for those on empirical therapy (P = 0.009), but at 1 year, there was little difference among the four strategies. Early endoscopy was associated with fewer subsequent consultations for dyspepsia (P = 0.003). 'Test and treat' resulted in fewer endoscopies overall and was most cost-effective over a range of cost assumptions. Empirical therapy resulted in the lowest initial costs, but the highest rate of subsequent endoscopy. Gastro-oesophageal cancers were found in four patients randomized to the H. pylori testing strategies. While early endoscopy offered some advantages 'Test and treat' was the most cost-effective strategy. In older patients, early endoscopy may be an appropriate strategy in view of the greater risk of malignant disease. © 2008 The Authors. Journal compilation © 2008 Blackwell Publishing Ltd.

  12. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    PubMed

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  13. Observation of nuclear reactors on satellites with a balloon-borne gamma-ray telescope

    NASA Technical Reports Server (NTRS)

    O'Neill, Terrence J.; Kerrick, Alan D.; Ait-Ouamer, Farid; Tumer, O. Tumay; Zych, Allen D.

    1989-01-01

    Four Soviet nuclear-powered satellites flying over a double Compton gamma-ray telescope resulted in the detection of gamma rays with 0.3-8.0 MeV energies on April 15, 1988, as the balloonborne telescope searched, from a 35-km altitude, for celestial gamma-ray sources. The satellites included Cosmos 1900 and 1932. The USSR is the only nation currently employing moderated nuclear reactors for satellite power; reactors in space may cause significant problems for gamma-ray astronomy by increasing backgrounds, especially in the case of gamma-ray bursts.

  14. Guidelines for Safety in the Gastrointestinal Endoscopy Unit

    PubMed Central

    Calderwood, Audrey H.; Chapman, Frank J.; Cohen, Jonathan; Cohen, Lawrence B.; Collins, James; Day, Lukejohn W.; Early, Dayna S.

    2014-01-01

    EXECUTIVE SUMMARY Historically, safety in the gastrointestinal (GI) endoscopy unit has focused on infection control, particularly around the reprocessing of endoscopes. Two highly publicized outbreaks where the transmission of infectious agents were related to GI endoscopy have highlighted the need to address potential gaps along the endoscopy care continuum that could impact patient safety. PMID:24485393

  15. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    PubMed

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  16. Safety of capsule endoscopy using human body communication in patients with cardiac devices.

    PubMed

    Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young

    2012-06-01

    The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

  17. Use and impact of early endoscopy in elderly patients with peptic ulcer hemorrhage: a population-based analysis.

    PubMed

    Cooper, Gregory S; Kou, Tzyung Doug; Wong, Richard C K

    2009-08-01

    Upper endoscopy performed within 1 day of presentation, or early endoscopy, has been proposed as an intervention to improve the efficiency and outcomes of care for patients with peptic ulcer hemorrhage. However, the use and outcomes have not been studied in a national, U.S.-based sample. To determine the prevalence and associated outcomes of early versus delayed endoscopy in bleeding peptic ulcers. Using a 5% random sample of inpatient and outpatient Medicare claims from 2004 in patients aged 66 years and older (mean [standard deviation] age 78.4 +/- 7.7 years), we identified 2592 patients, all of whom underwent endoscopy. Univariate and multivariate models were used to determine factors associated with 30-day mortality, upper GI surgery, and length of hospital stay. Early endoscopy was performed in 1854 patients (71.5%) and was somewhat more common with outpatient management. Early endoscopy was independently associated with a significant decrease in the length of hospital stay (-1.95 days, 95% CI, -2.60 to -1.29 days) as well as a lower likelihood of surgery (odds ratio, 0.37; 95% CI, 0.21-0.66). Early endoscopy was not associated with 30-day mortality in either univariate or multivariate analyses. Use of claims data lacking clinical detail and restriction to the Medicare-age population. In this population-based study of older patients with peptic ulcer hemorrhage, early endoscopy was associated with increased efficiency of care, lower rates of surgery, and potentially improved control of hemorrhage. Thus, unless specific contraindications exist, the data support the routine use of early endoscopy.

  18. Remote transmission of live endoscopy over the Internet: Report from the 87th Congress of the Japan Gastroenterological Endoscopy Society.

    PubMed

    Shimizu, Shuji; Ohtsuka, Takao; Takahata, Shunichi; Nagai, Eishi; Nakashima, Naoki; Tanaka, Masao

    2016-01-01

    Live demonstration of endoscopy is one of the most attractive and useful methods for education and is often organized locally in hospitals. However, problems have been apparent in terms of cost, preparation, and potential risks to patients. Our aim was to evaluate a new approach to live endoscopy whereby remote hospitals are connected by the Internet for live endoscopic demonstrations. Live endoscopy was transmitted to the Congress of the Japan Gastroenterological Endoscopic Society by 13 domestic and international hospitals. Patients with upper and lower gastrointestinal diseases and with pancreatobiliary disorders were the subjects of a live demonstration. Questionnaires were distributed to the audience and were sent to the demonstrators. Questions concerned the quality of transmitted images and sound, cost, preparations, programs, preference of style, and adverse events. Of the audience, 91.2% (249/273) answered favorably regarding the transmitted image quality and 93.8% (259/276) regarding the sound quality. All demonstrators answered favorably regarding image quality and 93% (13/14) regarding sound quality. Preparations were completed without any outsourcing at 11 sites (79%) and were evaluated as 'very easy' or 'easy' at all but one site (92.3%). Preparation cost was judged as 'very cheap' or 'cheap' at 12 sites (86%). Live endoscopy connecting multiple international centers was satisfactory in image and sound quality for both audience and demonstrators, with easy and inexpensive preparation. The remote transmission of live endoscopy from demonstrators' own hospitals was preferred to the conventional style of locally organized live endoscopy. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  19. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding.

    PubMed

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-07-07

    To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.

  20. Differences in clinical characteristics between patients with endoscopy-negative reflux disease and erosive esophagitis in Japan.

    PubMed

    Fujiwara, Yasuhiro; Higuchi, Kazuhide; Shiba, Masatsugu; Yamamori, Kazuki; Watanabe, Yoko; Sasaki, Eiji; Tominaga, Kazunari; Watanabe, Toshio; Oshitani, Nobuhide; Arakawa, Tetsuo

    2005-04-01

    Helicobacter pylori infection and atrophic gastritis are inversely related to erosive esophagitis. Whether these factors affect the pathogenesis of endoscopy-negative reflux disease is not clear. We aimed to elucidate the differences in clinical characteristics between endoscopy-negative erosive disease and erosive esophagitis. 253 subjects (89 with endoscopy-negative reflux disease and 164 with erosive esophagitis) were studied. Gastric atrophy was assessed by measurement of serum pepsinogen. Logistic regression was used to calculate the odds ratio (OR) and 95% confidence intervals (CI) of endoscopy-negative reflux disease compared with erosive esophagitis. Among GERD patients, female gender (OR = 2.27, 95% CI, 1.25-4.10), smoking (OR = 0.45, 95% CI, 0.22-0.91), and the presence of hiatal hernia (OR = 0.30, 95% CI, 0.17-0.56) were significantly associated with endoscopy-negative reflux disease compared with male gender, not smoking, and absence of hiatal hernia, respectively. Body mass index (BMI) was also significantly associated with a decreased OR for endoscopy-negative reflux disease. Although H. pylori infection and gastric atrophy were significantly more common in patients with endoscopy-negative reflux disease, these associations did not persist in a multiple-adjustment model. After adjustment for gender, BMI, smoking, and hiatal hernia, a decrease in serum pepsinogen I/II ratio was significantly associated with an increased OR for endoscopy-negative reflux disease (p for trend = 0.018). Female gender, low BMI, not smoking, absence of hiatal hernia, and severity of gastric atrophy were positively associated with endoscopy-negative reflux disease compared with erosive esophagitis among Japanese patients.

  1. Philipp Bozzini (1773-1809): The earliest description of endoscopy.

    PubMed

    Ramai, Daryl; Zakhia, Karl; Etienne, Denzil; Reddy, Madhavi

    2018-05-01

    The widespread use of endoscopy in today's clinical arena underscores its utility and growing significance within the field of medicine. Primitive forms of endoscopy have existed for hundreds of years, but it was not until the early 19th century that Dr Philipp Bozzini invented an endoscope that would form the basis of modern endoscopy. Born into an influential Italian family, Bozzini practiced medicine in a time and place of conflict and political unrest. His passion, ingenuity, and important social connections allowed him to create and introduce to the medical profession the Lichtleiter (light-conductor), which overcame two key issues plaguing endoscopy: inadequate lighting and poor penetration. A combination of professional rivalry and his premature passing stifled enthusiasm and further work on the Lichtleiter, but its value would not be lost forever. The advancements in the field of endoscopy that have come since the time of the Lichtleiter all build upon the principles of Bozzini, who became widely acknowledged as the father of modern endoscopy.

  2. Bacterial characteristics and clinical significance of ureteral double-J stents in children.

    PubMed

    García-Aparicio, L; Blázquez-Gómez, E; Martin, O; Krauel, L; de Haro, I; Rodó, J

    2015-01-01

    To determine the incidence of urinary tract infection in those patients that we have used an ureteral double-J stent as internal diversion after urological procedures. We reviewed all the medical records of patients who had a ureteral double-J stent after a urological procedure from August 2007 to May 2013. We have analyzed the following data: age, gender, type of prophylaxis, incidence of urinary tract infection (UTI), days of internal diversion with double-J stent, surgical procedure, bacterial characteristics, bacterial sensibility to antibiotics and UTI treatment. We have used 73 double-J stents as ureteral internal diversion in 67 patients with a mean age of 44.73±57.23. Surgical procedures were 50 laparoscopic Anderson-Hynes pyeloplasties in 49 patients, and 20 high-pressure balloon dilatation of the ureterovesical junction to treat primary obstructive megaureter in 15 patients; and 3 patients with ureterovesical obstruction after endoscopic treatment of vesicoureteral reflux. Forty three stents showed a bacterial colonization in cultures. Pseudomona aeruginosa was present in 9 (20.9%) stents. Only in 12 stents, bacterial colonization was sensible to antibiotic prophylaxis. Stent colonization was higher in boys and younger patients. Four patients had a febrile UTI. Incidence of UTI in younger patients that underwent HBPD of UVJ is higher. Bacterial colonization is frequent in double-J stents but the incidence of UTI is low. Double-J colonization is higher in younger patients. Patients that underwent HPBD have a higher risk of UTI related with ureteral double J stent. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Massive hemorrhage after Kasai portoenterostomy in a patient with a congenital extrahepatic portosystemic shunt, malrotation and a double aortic arch: report of a case.

    PubMed

    Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Tanaka, Yujiro; Sato, Kaori; Jimbo, Takahiro; Deie, Kyoichi; Koiwai, Kazuki; Nomura, Koji; Iwanaka, Tadashi

    2014-08-01

    A newborn female was transferred to our hospital presenting with severe respiratory distress. She underwent tracheal intubation and nasogastric tubing. Investigations revealed a congenital extrahepatic portosystemic shunt (CEPS) type 1, biliary atresia, heterotaxia, polysplenia, malrotation and a double aortic arch (DAA). She underwent the Kasai portoenterostomy and the Ladd procedure when she was 29 days old. On postoperative day 20, she developed sudden hematemesis with bright red blood. Endoscopy showed massive bleeding from an esophageal ulcer, and endoscopic therapy was performed successfully. During left thoracotomy, an aortoesophageal fistula (AEF) was detected and repaired by direct suturing. The postoperative course was uneventful. CEPS type 1 is commonly associated with other congenital malformations; however, there have been no previous reports of an association between CEPS and DAA. Nasogastric tube insertion in a patient with DAA can result in catastrophic AEF. The treatment strategy should be carefully considered in patients with CEPS type 1 and multiple congenital fetal anomalies.

  4. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis

    PubMed Central

    Palimaka, S; Blackhouse, Gord; Goeree, Ron

    2015-01-01

    Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion) would result in additional expenditure of about $763,000. Limitations In the literature on OGIB, estimates of rebleeding rates after endoscopic procedures or spontaneous cessation rates are unreliable, with a lack of data. Rough estimates from expert consultation can provide an indication of expected additional use of capsule endoscopy; however, a wide range of capsule uses was explored. Conclusions The budgetary impact in the first year in Ontario of capsule endoscopy use to complement push enteroscopy procedures ranges from $510,000 in savings to an additional expenditure of $2,036,000 (at 0% and 100% push enteroscopy procedures complemented, respectively). The expected scenario of 50% of push enteroscopy procedures likely to benefit from the use of capsule endoscopy, based on expert opinion, would result in additional expenditures of $763,000 in the first year. PMID:26355732

  5. Systematic alphanumeric-coded endoscopy versus chromoendoscopy for the detection of precancerous gastric lesions and early gastric cancer in subjects at average risk for gastric cancer.

    PubMed

    Pérez-Mendoza, A; Zárate-Guzmán, Á M; Galvis García, E S; Sobrino Cossío, S; Djamus Birch, J

    Gastric cancer is one of the main causes of cancer worldwide, but there is currently no global screening strategy for the disease. Endoscopy is the screening method of choice in some Asian countries, but no standardized technique has been recognized. Systematic alphanumeric-coded endoscopy can increase gastric lesion detection. The aim of the present article was to compare the usefulness of systematic alphanumeric-coded endoscopy with conventional endoscopy for the detection of premalignant lesions and early gastric cancer in subjects at average risk for gastric cancer. A cross-sectional, comparative, prospective, randomized study was conducted on patients at average risk for gastric cancer (40-50 years of age, no history of H. pylori infection, intestinal metaplasia, gastric atrophy, or gastrointestinal surgery). Before undergoing endoscopy, the patients had gastric preparation (200mg of oral acetylcysteine or 50mg of oral dimethicone). Conventional chromoendoscopy was performed with indigo carmine dye for contrast enhancement. Fifty consecutive cases (mean age 44.4 ± 3.34 years, 60% women, BMI 27.6 ± 5.82 kg/m 2 ) were evaluated. Endoscopic imaging quality was satisfactory in all the cases, with no differences between methods (p = 0.817). The detection rate of premalignant lesions and early gastric cancer was 14% (6 cases of intestinal metaplasia and one case of gastric adenocarcinoma). Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 95, 80, 100 and 96%, respectively, for systematic alphanumeric-coded endoscopy, and 100, 45, 20, 100, and 52%, respectively, for conventional endoscopy. Lesion detection through systematic alphanumeric-coded endoscopy was superior to that of conventional endoscopy (p = 0.003; OR = 12). Both techniques were effective, but systematic alphanumeric-coded endoscopy significantly reduced the false positive rate. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  6. Helical CT scan with 2D and 3D reconstructions and virtual endoscopy versus conventional endoscopy in the assessment of airway disease in neonates, infants and children.

    PubMed

    Yunus, Mahira

    2012-11-01

    To study the use of helical computed tomography 2-D and 3-D images, and virtual endoscopy in the evaluation of airway disease in neonates, infants and children and its value in lesion detection, characterisation and extension. Conducted at Al-Noor Hospital, Makkah, Saudi Arabia, from January 1 to June 30, 2006, the study comprised of 40 patients with strider, having various causes of airway obstruction. They were examined by helical CT scan with 2-D and 3-D reconstructions and virtual endoscopy. The level and characterisation of lesions were carried out and results were compared with actual endoscopic findings. Conventional endoscopy was chosen as the gold standard, and the evaluation of endoscopy was done in terms of sensitivity and specificity of the procedure. For statistical purposes, SPSS version 10 was used. All CT methods detected airway stenosis or obstruction. Accuracy was 98% (n=40) for virtual endoscopy, 96% (n=48) for 3-D external rendering, 90% (n=45) for multiplanar reconstructions and 86% (n=43) for axial images. Comparing the results of 3-D internal and external volume rendering images with conventional endoscopy for detection and grading of stenosis were closer than with 2-D minimum intensity multiplanar reconstruction and axial CT slices. Even high-grade stenosis could be evaluated with virtual endoscope through which conventional endoscope cannot be passed. A case of 4-year-old patient with tracheomalacia could not be diagnosed by helical CT scan and virtual bronchoscopy which was diagriosed on conventional endoscopy and needed CT scan in inspiration and expiration. Virtual endoscopy [VE] enabled better assessment of stenosis compared to the reading of 3-D external rendering, 2-D multiplanar reconstruction [MPR] or axial slices. It can replace conventional endoscopy in the assessment of airway disease without any additional risk.

  7. Patient satisfaction with the endoscopy experience and willingness to return in a central Canadian health region.

    PubMed

    Loftus, Russell; Nugent, Zoann; Graff, Lesley A; Schumacher, Frederick; Bernstein, Charles N; Singh, Harminder

    2013-01-01

    Patient experiences with endoscopy visits within a large central Canadian health region were evaluated to determine the relationship between the visit experience and the patients' willingness to return for future endoscopy, and to identify the factors associated with patients' willingness to return. A self-report survey was distributed to 1200 consecutive individuals undergoing an upper and⁄or lower gastrointestinal endoscopy at any one of the six hospital-based endoscopy facilities in the region. The Spearman correlation coefficient was used to assess the association between the patients' overall rating of the visits and willingness to return for repeat procedures under similar medical circumstances. Logistic regression analyses were performed to identify the factors associated with willingness to return for repeat endoscopy and overall satisfaction (rating) of the visit. A total of 529 (44%) individuals returned the questionnaire, with 45% rating the visit as excellent and 56% indicating they were extremely likely to return for repeat endoscopy. There was a low moderate correlation between overall rating of the visit and patients' willingness to return for repeat endoscopy (r=0.30). The factors independently associated with patient willingness to return for repeat endoscopy included perceived technical skills of the endoscopists (OR 2.7 [95% CI 1.3 to 5.5]), absence of pain during the procedure (OR 2.2 [95% CI 1.3 to 3.6]) and history of previous endoscopy (OR 2.4 [95% CI 1.4 to 4.1]). In contrast, the independent factors associated with the overall rating of the visit included information provided pre- and postprocedure, wait time before and on the day of the visit, and the physical environment. To facilitate patient return for needed endoscopy, it is important to assess patients' willingness to return because positive behavioural intent is not simply a function of satisfaction with the visit.

  8. Canadian Association of Gastroenterology consensus guidelines on safety and quality indicators in endoscopy

    PubMed Central

    Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dubé, Catherine; Enns, Robert; Hollingworth, Roger; MacIntosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J; Valori, Roland

    2012-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. OBJECTIVE: To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. METHODS: A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. RESULTS: Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. DISCUSSION: The consensus process identified a clear need for high-quality clinical and outcomes research to support quality improvement in the delivery of endoscopy services. CONCLUSIONS: The guidelines support quality improvement in endoscopy by providing explicit recommendations on systematic monitoring, assessment and modification of endoscopy service delivery to yield benefits for all patients affected by the practice of gastrointestinal endoscopy. PMID:22308578

  9. Suture marker lesion detection in the colon by self-stabilizing and unmodified capsule endoscopes: pilot study in acute canine models.

    PubMed

    Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N

    2013-02-01

    Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. Fireball multi object spectrograph: as-built optic performances

    NASA Astrophysics Data System (ADS)

    Grange, R.; Milliard, B.; Lemaitre, G.; Quiret, S.; Pascal, S.; Origné, A.; Hamden, E.; Schiminovich, D.

    2016-07-01

    Fireball (Faint Intergalactic Redshifted Emission Balloon) is a NASA/CNES balloon-borne experiment to study the faint diffuse circumgalactic medium from the line emissions in the ultraviolet (200 nm) above 37 km flight altitude. Fireball relies on a Multi Object Spectrograph (MOS) that takes full advantage of the new high QE, low noise 13 μm pixels UV EMCCD. The MOS is fed by a 1 meter diameter parabola with an extended field (1000 arcmin2) using a highly aspherized two mirror corrector. All the optical train is working at F/2.5 to maintain a high signal to noise ratio. The spectrograph (R 2200 and 1.5 arcsec FWHM) is based on two identical Schmidt systems acting as collimator and camera sharing a 2400 g/mm aspherized reflective Schmidt grating. This grating is manufactured from active optics methods by double replication technique of a metal deformable matrix whose active clear aperture is built-in to a rigid elliptical contour. The payload and gondola are presently under integration at LAM. We will present the alignment procedure and the as-built optic performances of the Fireball instrument.

  11. High-resolution ultraviolet observations of interstellar lines toward Zeta Persei observed with the balloon-borne ultraviolet stellar spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snow, T.P.; Lamers, H.J.G.L.M.; Joseph, C.L.

    1987-10-01

    The balloon-borne ultraviolet stellar spectrometer payload has been used to obtain high-resolution data on interstellar absorption lines toward Zeta Per. The only lines clearly present in the 2150-2450 region were several Fe II features, which show double structure. The two velocity components were sufficiently well separated that it was possible to construct separate curves of growth to derive the Fe II column densities for the individual components. These column densities and the component velocity separation were then used to compute a realistic two-component curve of growth for the line of sight to Zeta Per, which was then used to reanalyzemore » existing ultraviolet data from Copernicus. The results were generally similar to an earlier two-component analysis of the Copernicus data, with the important exception that the silicon depletion increased from near zero to about 1 dex. This makes the Zeta Per depletion pattern quite similar to those derived for other reddened lines of sight, supporting the viewpoint that the general diffuse interstellar medium has a nearly constant pattern of depletions. 31 references.« less

  12. Return glider radiosonde to measure temperature, humidity and radiation profiles through the atmosphere

    NASA Astrophysics Data System (ADS)

    Kraeuchi, Andreas; Philipona, Rolf

    2015-04-01

    Very promising radiation profile measurements through the atmosphere were made in 2011 with a balloon borne short- and longwave net radiometer. New and improved radiation sensors from Kipp&Zonen are now used in a glider aircraft together with a standard Swiss radiosonde from Meteolabor AG. This new return glider radiosonde (RG-R), is lifted up with double balloon technique to prevent pendulum motion and to keep the radiation instruments as horizontal as possible during the ascent measuring phase. The RG-R is equipped with a mechanism that allows to release the radiosonde at a preset altitude, and an autopilot allowing to fly the radiosonde back to the launch site and to land it savely with a parachute at a preset location. The return glider radiosonde technique as well as new measurement possibilities will be shown. First measurements show temperature, humidity and radiation profiles through the atmosphere up to 30 hPa (24 km) during different atmospheric conditions. Radiation profiles during different daytimes show possibilities with respect to temporal resolution of vertical radiation profiles trough the atmosphere.

  13. [Value of narrow band imaging endoscopy in detection of early laryngeal squamous cell carcinoma].

    PubMed

    Staníková, L; Kučová, H; Walderová, R; Zeleník, K; Šatanková, J; Komínek, P

    2015-01-01

    Narrow band imaging (NBI) is an endoscopic method using filtered wavelengths in detection of microvascular abnormalities associated with preneoplastic and neoplastic changes of the mucosa. The aim of the study is to evaluate the value of NBI endoscopy in the dia-gnosis of laryngeal precancerous and early stages of cancerous lesions and to investigate impact of NBI method in prehistological diagnostics in vivo. One hundred patients were enrolled in the study and their larynx was investigated using white light HD endoscopy and narrow band imaging between 6/ 2013- 10/ 2014. Indication criteria included chronic laryngitis, hoarseness for more than three weeks or macroscopic laryngeal lesion. Features of mucosal lesions were evaluated by white light endoscopy and afterwards were compared with intra-epithelial papillary capillary loop changes, viewed using NBI endoscopy. Suspicious lesions (leukoplakia, exophytic tumors, recurrent respiratory papillomatosis and/ or malignant type of vascular network by NBI endoscopy) were evaluated by histological analysis, results were compared with prehistological NBI dia-gnosis. Using NBI endoscopy, larger demarcation of pathological mucosal features than in white light visualization were recorded in 32/ 100 (32.0%) lesions, in 4/ 100 (4.0%) cases even new lesions were detected only by NBI endoscopy. 63/ 100 (63.0%) suspected lesions were evaluated histologically -  malign changes (carcinoma in situ or invasive carcinoma) were observed in 25/ 63 (39.7%). Prehistological diagnostics of malignant lesions using NBI endoscopy were in agreement with results of histological examination in 23/ 25 (92.0%) cases. The sensitivity of NBI in detecting malignant lesions was 89.3%, specificity of this method was 94.9%. NBI endoscopy is a promising optical technique enabling in vivo differentiation of superficial neoplastic lesions. These results suggest endoscopic NBI may be useful in the early detection of laryngeal cancer and precancerous lesions.

  14. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding

    PubMed Central

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-01-01

    AIM: To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. METHODS: Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. RESULTS: In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. CONCLUSION: The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding. PMID:25009396

  15. Endoscopy services in KwaZulu-Natal Province, South Africa, are insufficient for the burden of disease: Is patient care compromised?

    PubMed

    Loots, E; Clarke, D L; Newton, K; Mulder, C J

    2017-10-31

    Endoscopy services are central to the diagnosis and management of many gastrointestinal (GI) diseases. To evaluate the adequacy of endoscopy services in the public sector hospitals of KwaZulu-Natal (KZN) Province, South Africa, in 2016. A cross-sectional study was performed using a questionnaire completed by the clinical heads of endoscopy units in the public hospitals in KZN. The heads of 11 of the 12 endoscopy units responded. Two units were in tertiary-level hospitals and nine in regional hospitals. A total of 22 353 endoscopic procedures were performed annually, averaging 2 032 cases per annum per centre; they were performed by 89 endoscopists, of whom 72 (80.1%) were general surgeons. There were 0.06 registered gastroenterologists (GEs) per 100 000 population. Each endoscopist performed an average of 263 endoscopies per annum. There were 1.18 endoscopy rooms available per unit, and two units had on-site fluoroscopy available. The average waiting period for an upper endoscopy was 27 (range 7 - 60) days, for colonoscopy 29 (range 7 - 90) days and for duodenoscopy/endoscopic retrograde cholangiopancreatography 13 (range 4 - 20) days. This included patients with alarm symptoms for GI cancers. Equipment breakages interrupted most services, except for one hospital that had a service contract. Unit heads cited lack of equipment, trained staff and maintenance contracts as major shortcomings. Endoscopy units in KZN are not adequately equipped to deal with the endoscopy workload and services are plagued by frequent disruptions, which impact negatively on service delivery. There is a need to train more GEs. Patient care is compromised in these public hospitals.

  16. Alfentanil versus ketamine combined with propofol for sedation during upper gastrointestinal system endoscopy in morbidly obese patients

    PubMed Central

    Kılıc, Ertugrul; Demiriz, Barıs; Isıkay, Nurgül; Yıldırım, Abdullah E.; Can, Selman; Basmacı, Cem

    2016-01-01

    Objectives: To observe the effects of both propofol/alfentanil and propofol/ketamine on sedation during upper gastrointestinal system endoscopy in morbidly obese patients (UGSEMOP). Methods: In a prospective, double-blinded, randomized clinical study, 52 patients scheduled for UGSEMOP were assigned to either group A (n=26; 10 µg/kg intravenous [IV] alfentanil) or group K (n=26; 0.5 mg/kg IV ketamine). Each patient was administered 0.7 mg/kg propofol for induction. If it was needed, the patients were administered an additional dose of IV propofol. This study was performed in Sehitkamil State Hospital, Gaziantep, Turkey, between January 2014-2015. Total propofol consumption, time to achieve Modified Aldrete Scores (MAS) of 5 and 10 following the procedure, physician and patient satisfaction scores, and instances of side effects, such as bradycardia and hypotension were recorded. Results: Time to onset of sedation and duration of sedation were both significantly shorter in group A. Patients in group A also required less time to achieve an MAS of 5. Total propofol consumption was significantly lower in group A. Conclusion: Both propofol/alfentanil and propofol/ketamine combinations provided appropriate hypnosis and analgesia during UGSEMOP. However, propofol consumption was significantly higher using the propofol/ketamine combination. PMID:27761556

  17. Changing trends in oesophageal endoscopy: a systematic review of transnasal oesophagoscopy.

    PubMed

    Sabirin, Junainah; Abd Rahman, Maharita; Rajan, Philip

    2013-01-01

    The safety, efficacy, and economic implications of using transnasal oesophagoscopy (TNE) are compared with conventional rigid or flexible oesophagoscopy for oesophageal disorders in otorhinolaryngology (ORL) clinics in this systematic review. Eleven electronic databases were searched for articles on transnasal oesophagoscopy. A total of 67 relevant titles were identified and 39 abstracts were screened of which 17 full- text articles were included in this report. There was fair level of evidence to suggest that TNE was effective for screening examination in patients with dysphagia, globus pharyngeus, and reflux symptoms and for detection of metachronous oesophageal carcinoma. TNE can also be used to biopsy suspicious lesions in the upper aerodigestive tract, placement of wireless pH capsule, transnasal balloon dilation of the oesophagus, secondary tracheoesophageal puncture, and management of foreign bodies. TNE was well tolerated and can be safely performed in an office setting with topical anaesthesia. Complications associated with TNE were mild and uncommon. There was evidence to suggest potential cost savings by performing TNE in the office setting compared with conventional investigation and examination for dysphagia. TNE may lead to a change in practice from investigation and treatment in the operating theatre or day care center to an office-based practice.

  18. Changing Trends in Oesophageal Endoscopy: A Systematic Review of Transnasal Oesophagoscopy

    PubMed Central

    Sabirin, Junainah; Abd Rahman, Maharita; Rajan, Philip

    2013-01-01

    The safety, efficacy, and economic implications of using transnasal oesophagoscopy (TNE) are compared with conventional rigid or flexible oesophagoscopy for oesophageal disorders in otorhinolaryngology (ORL) clinics in this systematic review. Eleven electronic databases were searched for articles on transnasal oesophagoscopy. A total of 67 relevant titles were identified and 39 abstracts were screened of which 17 full- text articles were included in this report. There was fair level of evidence to suggest that TNE was effective for screening examination in patients with dysphagia, globus pharyngeus, and reflux symptoms and for detection of metachronous oesophageal carcinoma. TNE can also be used to biopsy suspicious lesions in the upper aerodigestive tract, placement of wireless pH capsule, transnasal balloon dilation of the oesophagus, secondary tracheoesophageal puncture, and management of foreign bodies. TNE was well tolerated and can be safely performed in an office setting with topical anaesthesia. Complications associated with TNE were mild and uncommon. There was evidence to suggest potential cost savings by performing TNE in the office setting compared with conventional investigation and examination for dysphagia. TNE may lead to a change in practice from investigation and treatment in the operating theatre or day care center to an office-based practice. PMID:23984101

  19. Distinct management issues with Crohn's disease of the small intestine.

    PubMed

    Fong, Steven C M; Irving, Peter M

    2015-03-01

    Small bowel Crohn's disease can present with clinical challenges that are specific to its location. In this review, we address some of the areas that present particular problems in small bowel Crohn's disease. A key issue specific to small bowel Crohn's disease relates to its diagnosis given that access to the small bowel is limited. Radiological advances, particularly in small bowel ultrasonography and MRI, as well as the introduction of capsule endoscopy and balloon enteroscopy are helping to address this. In addition, our ability to differentiate small bowel Crohn's disease from other causes of inflammation, such as tuberculosis, is improving on the basis of better understanding of the features that differentiate these conditions. It is also becoming apparent that jejunal Crohn's disease represents a distinct disease phenotype with potentially worse clinical outcomes. Finally, because it is a rare complication, our understanding of small bowel cancer associated with Crohn's disease remains limited. Recent publications are, however, starting to improve our knowledge of this condition. Although small bowel Crohn's disease presents specific management issues not seen in patients with Crohn's disease elsewhere in the gastrointestinal tract, our knowledge of how to manage these is improving.

  20. Weight loss endoscopy: Development, applications, and current status

    PubMed Central

    Kumar, Nitin

    2016-01-01

    Obesity and its comorbidities - including diabetes and obstructive sleep apnea - have taken a large and increasing toll on the United States and the rest of the world. The availability of commercial, clinical, and operative therapies for weight management have not been effective at a societal level. Endoscopic bariatric therapy is gaining acceptance as more effective than diet and lifestyle measures, and less invasive than bariatric surgery. Various endoscopic therapies are analogues of the restrictive or bypass components of bariatric surgery, utilizing gastric remodeling or intestinal anastomosis to achieve proven weight loss and metabolic benefits. Others, such as aspiration therapy, employ novel mechanisms of action. Intragastric balloons have recently been approved by the United States Food and Drug Administration, and a number of other technologies have completed large multicenter trials (such as AspireAssist aspiration therapy and Primary Obesity Surgery Endolumenal). Endoscopic sleeve gastroplasty and transoral outlet reduction for endoscopic revision of gastric bypass have proven safe and effective in a number of studies. As devices are approved for use, data will continue to accumulate for safety, effectiveness, and cost effectiveness. Bariatric endoscopists should be prepared to appropriately target and apply various endoscopic bariatric therapies in the context of a comprehensive long-term weight management program. PMID:27610017

  1. Pediatric gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) and European Society for Paediatric Gastroenterology Hepatology and Nutrition (ESPGHAN) Guideline Executive summary.

    PubMed

    Tringali, Andrea; Thomson, Mike; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf Dietrich; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro

    2017-01-01

    This Executive summary of the Guideline on pediatric gastrointestinal endoscopy from the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society for Paediatric Gastroenterology Hepatology and Nutrition (ESPGHAN) refers to infants, children, and adolescents aged 0 - 18 years. The areas covered include: indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; endoscopic management of corrosive ingestion and stricture/stenosis; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography, and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease (IBD) have been dealt with in other Guidelines and are therefore not mentioned in this Guideline. Training and ongoing skill maintenance will be addressed in an imminent sister publication. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) quality improvement initiative

    PubMed Central

    Thomas-Gibson, Siwan; Bugajski, Marek; Bretthauer, Michael; Rees, Colin J; Dekker, Evelien; Hoff, Geir; Jover, Rodrigo; Suchanek, Stepan; Ferlitsch, Monika; Anderson, John; Roesch, Thomas; Hultcranz, Rolf; Racz, Istvan; Kuipers, Ernst J; Garborg, Kjetil; East, James E; Rupinski, Maciej; Seip, Birgitte; Bennett, Cathy; Senore, Carlo; Minozzi, Silvia; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Spada, Cristiano; Hassan, Cesare; Dinis-Ribeiro, Mario; Rutter, Matthew D

    2017-01-01

    The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level: 1 rate of adequate bowel preparation (minimum standard 90%); 2 cecal intubation rate (minimum standard 90%); 3 adenoma detection rate (minimum standard 25%); 4 appropriate polypectomy technique (minimum standard 80%); 5 complication rate (minimum standard not set); 6 patient experience (minimum standard not set); 7 appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures. PMID:28507745

  3. High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy.

    PubMed

    Penny, Hugo A; Mooney, Peter D; Burden, Mitchell; Patel, Nisha; Johnston, Alexander J; Wong, Simon H; Teare, Julian; Sanders, David S

    2016-06-01

    Celiac disease remains underdiagnosed at endoscopy. We aimed to assess the utility of I-Scan (virtual chromo-endoscopy) to improve sensitivity of endoscopy to detect markers of villous atrophy in this condition. Patients from 2 UK hospitals were studied in 3 groups. Group 1: standard high definition, white light endoscopy (WLE); Group 2: WLE plus I-Scan; Group 3: non-high definition control group. The presence of endoscopic markers was recorded. At least 4 duodenal biopsies were taken from all patients. Serology was performed concurrently and observations were compared with histology. 758 patients (62% female, mean age 52) were recruited (Group 1: 230; Group 2: 228; Group 3: 300). 135 (17.8%) new diagnoses of coeliac disease were made (21 Group 1; 24 Group 2; 89 Group 3). The sensitivity for detection of endoscopic markers of villous atrophy was significantly higher in both Group 1 (85.7%, p=0.0004) and Group 2 (75%, p=0.005) compared to non-high definition controls (41.6%). There was no significant difference between high definition only and I-Scan groups (p=0.47). In non-high definition endoscopy a missed diagnosis was associated with lesser degrees of villous atrophy (p=0.019) and low tTG titre (p=0.007). High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Immediate Clinical and Echocardiographic Outcome of Percutaneous Transvenous Mitral Commissurotomy for Patients of Mitral Stenosis with Atrial Fibrillation.

    PubMed

    Rahman, M T; Rahman, M M; Islam, M M; Khan, M R; Haque, S A; Chowdhury, A W; Majumder, A S; Rahman, A; Islam, Q I

    2015-07-01

    Rheumatic fever and rheumatic heart disease continue to be the major health problem in all developing countries including Bangladesh. Rheumatic mitral stenosis is a very common problem in our population having an incidence of 54 percent among rheumatic heart disease with a female preponderance of 2:1. Percutaneous balloon mitral commissurotomy is appealing because the mechanism of valve dilation closely parallels the mechanism of surgical mitral commissurotomy. The technique of balloon mitral commissurotomy has evolved rapidly, with improvements in balloons, guide wires, and the application of double-balloon techniques. There is controversy that whether the presence of AF has a direct negative effect on the immediate or long-term outcome after PTMC in mitral stenosis patients. The purpose of this study was to see the effect of atrial fibrillation (AF) on the immediate clinical and echocardiographic outcome of patients undergoing Percutaneous Transvenous Mitral Commissurotomy (PTMC). The immediate procedural and in-hospital clinical outcome after PTMC of 264 patients with AF were prospectively collected and compared with those of 288 patients in normal sinus rhythm (NSR) with mitral stenosis admitted in National Institute of Cardiovascular Diseases, Dhaka and Al-Helal Heart Institute, Mirpur, Dhaka, Bangladesh. Patients with AF were older than patients with normal sinus rhythm (53 ± 11 vs. 33 ± 12 years; p<0.0001) and presented more frequently with New York Heart Association (NYHA) class III-IV (78.3% vs. 58.5%; p<0.0001), echocardiographic score >8 (38.9% vs. 22.7%; p<0.0001), calcified valves under fluoroscopy (22.2% vs.12.4%, p<0.0001) and with history of previous surgical commissurotomy (21.7% vs. 10.5%; p<0.0001). In patients with AF, PTMC resulted in worse outcomes, as reflected in a smaller post-PTMC mitral valve area (1.6±0.4 vs. 2.1 ± 0.8 cm²; p<0.0001). Patients with atrial fibrillation have a worse immediate clinical and echocardiographic outcome after PTMC.

  5. [Brief history of interventional radiology].

    PubMed

    Tang, Zhenliang; Jia, Aiqin; Li, Luoyun; Li, Chunyu

    2014-05-01

    In 1923, angiography was first successively used for the human body. In 1953, a Swedish doctor Sven-Ivar Seldinger pioneered the Seldinger technique, which laid down the foundation of interventional radiology. In 1963, Charles Dotter first proposed the idea of interventional radiology. In 1964, Charles Dotter opened a new era of percutaneous angioplasty through accidental operation, marking the formation of interventional radiology. On this basis, the techniques of balloon catheter dilation and metal stent implantation was developed. Endovascular stent was proposed in 1969. In 1973, the percutaneous angioplasty has been a breakthrough with the emergence of soft double-lumen balloon catheter. Percutaneous coronary angioplasty is applied in 1977. Since the 1990s, balloon angioplasty relegated to secondary status with the emergence of metal stent. Currently, endovascular stent have entered a new stage with the emergence of temporary stent and stent grafts and biological stent. Transcatheter arterial embolization had been one of the most important basic techniques for interventional radiology since 1965, it had also been a corresponding development with the improvement of embolic agents and catheter technology for the treatment of diseases now. Transjugular intrahepatic portosystemic stent-shunt is a comprehensive interventional radiology technology since 1967, in which the biliary system can be reached through a jugular vein, and the improvement appeared with balloon expandable stent in 1986.Since 1972, non-vascular interventional techniques was another important branch of interventional radiology. Currently, it is applied in the diagnosis and treatment of many diseases of the internal organs like the pancreas, liver, kidney, spinal cord, Fallopian tubes, esophagus and other organs. In 1973, Chinese radiologist first conducted the angiography test. Interventional radiology was introduced into China in the 1980s, it was readily developed through the sponsoring of training class (1981) and academic conferences (1986). Along with the return of the overseas scholars, the gap in the interventional diagnosis and treatment technology between China and the world has been narrowing since the 1990s.

  6. Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.

    PubMed

    Kim, Jin Woo; Kim, Byung Moon; Park, Keun Young; Kim, Dong Joon; Kim, Dong Ik

    2016-05-01

    Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization.

  7. From POEM to POET: Applications and perspectives for submucosal tunnel endoscopy.

    PubMed

    Chiu, Philip W Y; Inoue, Haruhiro; Rösch, Thomas

    2016-12-01

    Recent advances in submucosal endoscopy have unlocked a new horizon for potential development in diagnostic and therapeutic endoscopy. Increasing evidence has demonstrated that peroral endoscopic myotomy (POEM) is not only clinically feasible and safe, but also has excellent results in symptomatic relief of achalasia. The success of submucosal endoscopy in performance of tumor resection has confirmed the potential of this new area in diagnostic and therapeutic endoscopy. This article reviews the current applications and evidence, from POEM to peroral endoscopic tunnel resection (POET), while exploring the possible future clinical applications in this field. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Calibration and performance of the UCR double Compton gamma ray telescope

    NASA Technical Reports Server (NTRS)

    Ait-Ouamer, Farid; Kerrick, Alan D.; Sarmouk, Abderrezak; O'Neill, Terrence J.; Sweeney, William E.

    1990-01-01

    Results of the field calibration and performance of the UCR double Compton gamma-ray telescope are presented. The telescope is a balloon-borne instrument with an upper array of 16 plastic scintillator bars and a lower one of 16 NaI(Tl) bars. The telescope is sensitive to celestial gamma rays from 1 to 30 MeV. The data were collected on February 14, 1988 prior to launch in Alice Springs, Australia to observe SN 1987A. Radioactive sources were used to calibrate the energy deposits in the scintillators. Each bar was analyzed laterally using pulse height or timing to obtain the positions of the gamma ray interactions. Double scatter events from an Na-24 source simulating a celestial source were studied to obtain the general performance of the telescope and to develop imaging techniques, later used with the flight data. An angular resolution of 11 deg FWHM and energy resolutions of 13 and 10 percent FWHM at 1.37 and 2.75 MeV, respectively, were found. The efficiency of the telescope is 0.0035 at 1.37 MeV and zenith angle 31 deg.

  9. Robotics in endoscopy.

    PubMed

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  10. Ideal MHD stability of double transport barrier plasmas in DIII-D

    NASA Astrophysics Data System (ADS)

    Li, G. Q.; Wang, S. J.; Lao, L. L.; Turnbull, A. D.; Chu, M. S.; Brennan, D. P.; Groebner, R. J.; Zhao, L.

    2008-01-01

    The ideal MHD stability for double transport barrier (DTB or DB) plasmas with varying edge and internal barrier width and height was investigated, using the ideal MHD stability code GATO. A moderate ratio of edge transport barriers (ETB) height to internal transport barriers (ITBs) height is found to be beneficial to MHD stability and the βN is limited by global low n instabilities. For moderate ITB width DB plasmas, if the ETB is weak, the stability is limited by n = 1 (n is the toroidal mode number) global mode; whereas if the ETB is strong it is limited by intermediate-n edge peeling-ballooning modes. Broadening the ITB can improve stability if the ITB half width wi lsim 0.3. For very broad ITB width plasmas the stability is limited by stability to a low n (n > 1) global mode.

  11. Technique and Preliminary Analysis of Drug-Induced Sleep Endoscopy With Online Polygraphic Cardiorespiratory Monitoring in Patients With Obstructive Sleep Apnea Syndrome.

    PubMed

    Gobbi, Riccardo; Baiardi, Simone; Mondini, Susanna; Cerritelli, Luca; Piccin, Ottavio; Scaramuzzino, Giuseppe; Milano, Francesca; Melotti, Maria Rita; Mordini, Francesco; Pirodda, Antonio; Cirignotta, Fabio; Sorrenti, Giovanni

    2017-05-01

    Drug-induced sleep endoscopy is a diagnostic technique that allows dynamic evaluation of the upper airway during artificial sleep. The lack of a standardized procedure and the difficulties associated with direct visual detection of obstructive events result in poor intraobserver and interobserver reliability, especially when otolaryngology surgeons not experienced in the technique are involved. To describe a drug-induced sleep endoscopy technique implemented with simultaneous polygraphic monitoring of cardiorespiratory parameters (DISE-PG) in patients with a diagnosis of obstructive sleep apnea syndrome and discuss the technique's possible advantages compared with the standard procedure. This prospective cohort study included 50 consecutive patients with obstructive sleep apnea syndrome who underwent DISE-PG from March 1, 2013, to June 30, 2014. A standard protocol was adopted, and all the procedures were carried out in an operation room by an experienced otolaryngology surgeon under the supervision of an anesthesiologist. Endoscopic and polygraphic obstructive respiratory events were analyzed offline in a double-blind setting and randomized order. The feasibility and safety of the DISE-PG technique, as well as its sensitivity in detecting respiratory events compared with that of the standard drug-induced sleep endoscopy procedure. All 50 patients (43 men and 7 women; mean [SD] age, 51.1 [12.1] years) underwent DISE-PG without technical problems or patient difficulties regarding the procedure. As expected, polygraphic scoring was more sensitive than endoscopic scoring in identifying obstructive events (mean [SD] total events, 13.3 [6.8] vs 5.3 [3.6]; mean [SD] difference, 8.8 [5.6]; 95% CI, 7.3 to 10.4; Cohen d, -1.5). This difference was most pronounced in patients with a higher apnea-hypopnea index (AHI) at baseline (mean [SD] difference for AHI >30, 27.1% [31.0%]; 95% CI, -36.2% to 90.4%; Cohen d, 0.2; for AH I >40, 76.0% [35.5%]; 95% CI, 4.6% to 147.4%; Cohen d, 0.5; for AHI >50, 92.2% [37.2%]; 95% CI, 17.3% to 167.1%; Cohen d, 0.6) and a high percentage of hypopneas (≥75% of all obstructive events) at baseline (mean [SD] difference, 20.2% [5.4%]; 95% CI, 9.2% to 31.3%; Cohen d, 1.1). No other anthropomorphic or polygraphic features at baseline were associated with the differences between the DISE-PG and baseline home sleep apnea test. The DISE-PG technique is feasible, safe, and more sensitive at detecting an obstructed breathing pattern than is drug-induced sleep endoscopy alone. The DISE-PG technique could be helpful for accurate comprehension of upper airway obstructive dynamics (ie, degree of obstruction and multilevel pattern) and a nonobstructive breathing pattern (ie, central apneas).

  12. Light and sound - emerging imaging techniques for inflammatory bowel disease

    PubMed Central

    Knieling, Ferdinand; Waldner, Maximilian J

    2016-01-01

    Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing from year to year. New, mostly non-radiant, quick to perform and quantitative methods are challenging, conventional endoscopy with biopsy as gold standard. Especially, new physical imaging approaches utilizing light and sound waves have facilitated the development of advanced functional and molecular modalities. Besides these advantages they hold the promise to predict personalized therapeutic responses and to spare frequent invasive procedures. Within this article we highlight their potential for initial diagnosis, assessment of disease activity and surveillance of cancer development in established techniques and recent advances such as wide-view full-spectrum endoscopy, chromoendoscopy, autofluorescence endoscopy, endocytoscopy, confocal laser endoscopy, multiphoton endoscopy, molecular imaging endoscopy, B-mode and Doppler ultrasound, contrast-enhanced ultrasound, ultrasound molecular imaging, and elastography. PMID:27433080

  13. Esophageal mucosal breaks in gastroesophageal reflux disease partially responsive to proton pump inhibitor therapy.

    PubMed

    Shaheen, Nicholas J; Denison, Hans; Björck, Karin; Silberg, Debra G

    2013-04-01

    Approximately 20-30% of patients with gastroesophageal reflux disease (GERD) do not experience complete symptom resolution during proton pump inhibitor (PPI) therapy. The aim of this study was to determine the prevalence of esophageal mucosal breaks among patients who have a partial response to PPI therapy. This was an analysis of data from a phase 2b clinical trial carried out to assess the efficacy and safety of a reflux inhibitor, lesogaberan (AZD3355), as an add-on to PPI therapy in this patient population (clinicaltrials.gov reference: NCT01005251). A total of 661 patients with persistent GERD symptoms who had received a minimum of 4 weeks of PPI therapy were included in the study. The prevalence of esophageal mucosal breaks was assessed according to (i) the most recent endoscopy results from within the previous 24 months, if available ("historical" endoscopies), and (ii) the results of endoscopies performed at study baseline ("baseline" endoscopies). Baseline endoscopies were not carried out in patients who had a historical endoscopy showing an absence of esophageal mucosal breaks. Historical endoscopy results were available for 244 patients, of whom 48 (19.7%) had esophageal mucosal breaks. Baseline endoscopies were carried out in 465 patients, of whom 146 (31.4%) had esophageal mucosal breaks. Sensitivity analyses showed a prevalence of esophageal mucosal breaks of 20-30%. In both the historical and baseline endoscopies, most esophageal mucosal breaks were Los Angeles grades A or B. In patients with GERD symptoms partially responsive to PPI therapy, mild-to-moderate severity esophageal mucosal breaks are common (prevalence 20-30%), and may contribute to symptom etiology.

  14. Reduced hemoglobin and increased C-reactive protein are associated with upper gastrointestinal bleeding.

    PubMed

    Tomizawa, Minoru; Shinozaki, Fuminobu; Hasegawa, Rumiko; Togawa, Akira; Shirai, Yoshinori; Ichiki, Noboru; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Sueishi, Makoto

    2014-02-07

    To investigate the early upper gastrointestinal endoscopy (endoscopy) significantly reduces mortality resulting from upper gastrointestinal (GI) bleeding. Upper GI bleeding was defined as 1a, 1b, 2a, and 2b according to the Forrest classification. The hemoglobin (Hb), and C-reactive protein (CRP) were examined at around the day of endoscopy and 3 mo prior to endoscopy. The rate of change was calculated as follows: (the result of blood examination on the day of endoscopy - the results of blood examination 3 mo prior to endoscopy)/(results of blood examination 3 mo prior to endoscopy). Receiver operating characteristic curves were created to determine threshold values. Seventy-nine men and 77 women were enrolled. There were 17 patients with upper GI bleeding: 12 with a gastric ulcer, 3 with a duodenal ulcer, 1 with an acute gastric mucosal lesion, and 1 with gastric cancer. The area under the curve (AUC), threshold, sensitivity, and specificity of Hb around the day of endoscopy were 0.902, 11.7 g/dL, 94.1%, and 77.1%, respectively, while those of CRP were 0.722, 0.5 mg/dL, 70.5%, and 73%, respectively. The AUC, threshold, sensitivity, and specificity of the rate of change of Hb were 0.851, -21.3%, 76.4%, and 82.6%, respectively, while those of CRP were 0.901, 100%, 100%, and 82.5%, respectively. Predictors for upper GI bleeding were Hb < 11.7 g/dL, reduction rate in the Hb > 21.3% and an increase in the CRP > 100%, 3 mo before endoscopy.

  15. [Virtual endoscopy with a volumetric reconstruction technic: the technical aspects].

    PubMed

    Pavone, P; Laghi, A; Panebianco, V; Catalano, C; Giura, R; Passariello, R

    1998-06-01

    We analyze the peculiar technical features of virtual endoscopy obtained with volume rendering. Our preliminary experience is based on virtual endoscopy images from volumetric data acquired with spiral CT (Siemens, Somatom Plus 4) using acquisition protocols standardized for different anatomic areas. Images are reformatted at the CT console, to obtain 1 mm thick contiguous slices, and transferred in DICOM format to an O2 workstation (Silicon Graphics, Mountain View CA, USA) with processor speed of 180 Mhz, 256 Mbyte RAM memory and 4.1 Gbyte hard disk. The software is Vitrea 1.0 (Vital Images, Fairfield, Iowa), running on a Unix platform. Image output is obtained through the Ethernet network to a Macintosh computer and a thermic printer (Kodak 8600 XLS). Diagnostic quality images were obtained in all the cases. Fly-through in the airways allowed correct evaluation of the main bronchi and of the origin of segmentary bronchi. In the vascular district, both carotid strictures and abdominal aortic aneurysms were depicted, with the same accuracy as with conventional reconstruction techniques. In the colon studies, polypoid lesions were correctly depicted in all the cases, with good correlation with endoscopic and double-contrast barium enema findings. In a case of lipoma of the ascending colon, virtual endoscopy allowed to study the colon both cranially and caudally to the lesion. The simultaneous evaluation of axial CT images permitted to characterize the lesion correctly on the basis of its density values. The peculiar feature of volume rendering is the use of the whole information inside the imaging volume to reconstruct three-dimensional images; no threshold values are used and no data are lost as opposite to conventional image reconstruction techniques. The different anatomic structures are visualized modifying the reciprocal opacities, showing the structures of no interest as translucent. The modulation of different opacities is obtained modifying the shape of the opacity curve, either using pre-set curves or in a completely independent way. Other technical features of volume rendering are the perspective evaluation of the objects, color and lighting. In conclusion, volume rendering is a promising technique to elaborate three-dimensional images, offering very realistic endoscopic views. At present, the main limitation is represented by the need of powerful and high-cost workstations.

  16. Helicobacter pylori-negative gastric mucosa-associated lymphoid tissue lymphoma: magnifying endoscopy findings.

    PubMed

    Law, T T; Tong, Daniel; Wong, Sam W H; Chan, S Y; Law, Simon

    2015-04-01

    Gastric mucosa-associated lymphoid tissue lymphoma is uncommon and most patients have an indolent clinical course. The clinical presentation and endoscopic findings can be subtle and diagnosis can be missed on white light endoscopy. Magnifying endoscopy may help identify the abnormal microstructural and microvascular patterns, and target biopsies can be performed. We describe herein the case of a 64-year-old woman with Helicobacter pylori-negative gastric mucosa-associated lymphoid tissue lymphoma diagnosed by screening magnification endoscopy. Helicobacter pylori-eradication therapy was given and she received biological therapy. She is in clinical remission after treatment. The use of magnification endoscopy in gastric mucosa-associated lymphoid tissue lymphoma and its management are reviewed.

  17. Moving Raman spectroscopy into real-time, online diagnosis and detection of precancer and cancer in vivo in the upper GI during clinical endoscopic examination

    NASA Astrophysics Data System (ADS)

    Huang, Zhiwei; Bergholt, Mads Sylvest; Zheng, Wei; Ho, Khek Yu; Yeoh, Khay Guan; Teh, Ming; So, Jimmy Bok Yan; Shabbir, Asim

    2013-03-01

    A rapid image-guided Raman endoscopy system integrated with on-line diagnostic scheme is developed for in vivo Raman tissue diagnosis (optical biopsy) in the upper GI during clinical gastrointestinal endoscopy under multimodal wide-field imaging guidance. The real-time Raman endoscopy technique was tested prospectively on new gastric patients (n=4) and could identify dysplasia in vivo with sensitivity of 81.5% (22/27) and specificity of 87.9% (29/33). This study realizes for the first time the novel image-guided Raman endoscopy as a screening tool for real-time, online diagnosis of gastric cancer and precancer in vivo at endoscopy.

  18. Flexible Gastrointestinal Endoscopy in Ferrets (Mustela putorius furo).

    PubMed

    Pignon, Charly; Huynh, Minh; Husnik, Roman; Jekl, Vladimir

    2015-09-01

    Gastrointestinal disease is a common complaint in ferrets (Mustela putorius furo). Their relatively simple and short gastrointestinal tract makes them good candidates for flexible endoscopy. However, apart from a few references in biomedical research articles, there is little information on the use of flexible endoscopy in ferrets. This review describes patient preparation, equipment, and select gastrointestinal endoscopy techniques in ferrets, including esophagoscopy, gastroscopy, duodenoscopy, percutaneous endoscopic gastrostomy, jejunoileoscopy, colonoscopy, and biopsy. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Microprocessor-controlled laser tracker for atmospheric sensing

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.; Webster, C. R.; Menzies, R. T.

    1985-01-01

    An optical tracking system comprising a visible HeNe laser, an imaging detector, and a microprocessor-controlled mirror, has been designed to track a moving retroreflector located up to 500 m away from an atmospheric instrument and simultaneously direct spectrally tunable infrared laser radiation to the retroreflector for double-ended, long-path absorption measurements of atmospheric species. The tracker has been tested during the recent flight of a balloon-borne tunable diode laser absorption spectrometer which monitors the concentrations of stratospheric species within a volume defined by a 0.14-m-diameter retroreflector lowered 500 m below the instrument gondola.

  20. Balloon mitral valvuloplasty during pregnancy--our experience.

    PubMed

    Salomé, Nuno; Dias, Carla C; Ribeiro, José; Gonçalves, Manuel; Fonseca, Conceição; Ribeiro, Vasco Gama

    2002-12-01

    Mitral stenosis is the most common valvular heart lesion found in pregnancy. When severe, it leads to significant maternal and fetal morbidity and mortality, since the hemodynamic adaptations to pregnancy are badly tolerated. Pregnancy can lead to development of heart failure in patients with asymptomatic or even unknown mitral stenosis, as a result of the increased mitral valve pressure gradient caused by the physiologic increase in heart rate and blood volume in pregnancy. When symptoms persist despite optimal medical therapy, the poor prognosis justifies the correction of mitral stenosis during pregnancy. To present our experience in treating severe mitral stenosis in women who develop severe heart failure during pregnancy, using percutaneous balloon mitral valvuloplasty. From 1996 to March 2002, in our department, 47 balloon mitral valvuloplasties were successfully performed in women, three of them pregnant. These were patients with congestive heart failure, New York Heart Association (NYHA) functional class III or IV, at the end of the second trimester of pregnancy, who did not respond positively to drug treatment with diuretics and digitalis. We performed percutaneous balloon mitral valvuloplasty using the Inoue technique in the three pregnant patients, with success, at around 25 weeks of gestation. After the procedure, the patients showed clinical improvement, returning to the NYHA functional class that they were in before becoming pregnant (I-II). The previous mitral valve area was 0.9-1.2 cm2, nearly doubling after valvuloplasty. Mean left atrial pressure decreased on average by 42%, and the maximum pressure (V wave) decreased on average by 40%. The mitral valve pressure gradient decreased from 15, 10 and 28 mmHg to 7, 5 and 5 mmHg after valvuloplasty. During the procedure there were no maternal or fetal complications. All patients were discharged 24 to 48 h after valvuloplasty, continuing their pregnancies without complications. One woman had vaginal delivery, and the other two had cesarean sections at 35 weeks of gestation, all without complications with healthy newborns that developed normally. In follow-up, one patient who had moderate mitral regurgitation after valvuloplasty developed severe mitral regurgitation, requiring surgical correction after two years. In pregnant patients who have severe mitral stenosis and persistent congestive heart failure symptoms despite conventional medical treatment, when feasible, percutaneous balloon mitral valvuloplasty is the best treatment.

  1. Telescope Systems for Balloon-Borne Research

    NASA Technical Reports Server (NTRS)

    Swift, C. (Editor); Witteborn, F. C. (Editor); Shipley, A. (Editor)

    1974-01-01

    The proceedings of a conference on the use of balloons for scientific research are presented. The subjects discussed include the following: (1) astronomical observations with balloon-borne telescopes, (2) orientable, stabilized balloon-borne gondola for around-the-world flights, (3) ultraviolet stellar spectrophotometry from a balloon platform, (4) infrared telescope for balloon-borne infrared astronomy, and (5) stabilization, pointing, and command control of balloon-borne telescopes.

  2. Pilot randomized crossover study comparing the efficacy of transnasal disposable endosheath with standard endoscopy to detect Barrett's esophagus.

    PubMed

    Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano

    2016-02-01

    The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P < 0.0001). However, following endoscopy, patients reported a significantly better experience with TEE compared with standard endoscopy (7.05 ± 0.49 vs. 4.35 ± 0.53; P = 0.0006), with 60 % preferring TEE and 25 % preferring sedated standard endoscopy. In this study, TEE had equal accuracy for an endoscopic diagnosis of Barrett's esophagus compared with standard endoscopy, at the expense of reduced image quality and a lower yield of intestinal metaplasia on biopsy. TEE was better tolerated and preferred by patients. Hence, TEE needs further evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Leadership and team building in gastrointestinal endoscopy.

    PubMed

    Valori, Roland M; Johnston, Deborah J

    2016-06-01

    A modern endoscopy service delivers high volume procedures that can be daunting, embarrassing and uncomfortable for patients [1]. Endoscopy is hugely beneficial to patients but only if it is performed to high standards [2]. Some consequences of poor quality endoscopy include worse outcomes for cancer and gastrointestinal bleeding, unnecessary repeat procedures, needless damage to patients and even avoidable death [3]. New endoscopy technology and more rigorous decontamination procedures have made endoscopy more effective and safer, but they have placed additional demands on the service. Ever-scarcer resources require more efficient, higher turnover of patients, which can be at odds with a good patient experience, and with quality and safety. It is clear from the demands put upon it, that to deliver a modern endoscopy service requires effective leadership and team working [4]. This chapter explores what constitutes effective leadership and what makes great clinical teams. It makes the point that endoscopy services are not usually isolated, independent units, and as such are dependent for success on the organisations they sit within. It will explain how endoscopy services are affected by the wider policy and governance context. Finally, within the context of the collection of papers in this edition of Best Practice & Research: Clinical Gastroenterology, it explores the potentially conflicting relationship between training of endoscopists and service delivery. The effectiveness of leadership and teams is rarely the subject of classic experimental designs such as randomized controlled trials. Nevertheless there is a substantial literature on this subject within and particularly outside healthcare [5]. The authors draw on this wider, more diffuse literature and on their experience of delivering a Team Leadership Programme (TLP) to the leaders of 70 endoscopy teams during the period 2008-2012. (Team Leadership Programme Link-http://www.qsfh.co.uk/Page.aspx?PageId=Public). Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Colonoscopy in the office setting is safe, and financially sound ... for now.

    PubMed

    Luchtefeld, Martin A; Kim, Donald G

    2006-03-01

    In 2000, the Centers for Medicare & Medicaid Services announced a plan to allow for enhanced reimbursement for office endoscopy. This change in reimbursement was phased in during three years. The purpose of this study was to evaluate the fiscal outcomes and quality measures in the first two and a one-half years of performing endoscopy in an office setting under the new Centers for Medicare & Medicaid Services guidelines. The following financial parameters were gathered: number of endoscopies, expenses (divided into salaries and operational), net revenue, and margin for endoscopies performed in the office compared with the hospital. All endoscopies were performed by endoscopists with advanced training (gastroenterology fellowship or colon and rectal surgery residency). Monitoring equipment included continuous SaO2 and automated blood pressure in all patients and continuous electrocardiographic monitors in selected patients. Quality/safety data have been tracked in a prospective manner and include number of transfers to the hospital, perforations, bleeding requiring transfusion or hospitalization, and cardiorespiratory arrest. The financial outcomes are as follows: 13,285 endoscopies performed from the opening of the unit through December 2003; net revenue per case $504 per case; expense per case has dropped from $205 per case to $145 per case; the overall financial benefit of performing endoscopy in the office compared with the hospital was an additional $28 to $143 per case depending on the insurance carrier. The quality outcomes since inception of the unit include the following: 13,285 endoscopies; 0 hospital transfers, 0 cardiorespiratory arrests; 0 perforations; and 1 bleeding episode that required hospitalization. Endoscopy performed in the office setting is safe when done with appropriate monitoring and in the proper patient population. At the time of this study, office endoscopy also is financially rewarding but changes in Centers for Medicare & Medicaid Services reimbursement threaten the ability to retain any financial benefit.

  5. Diffusion of knowledge about Helicobacter pylori as assessed in an open-access endoscopy system: a prospective observational study based on the Maastricht guidelines.

    PubMed

    Manes, G; Mosca, S; Balzano, A; Amitrano, L; Bove, A; de Nucci, C; Guardascione, M A; Lombardi, G; Picascia, S; Riccio, E; Rocco, P V

    2001-01-01

    Aim of the present study is to assess, according to the guidelines of the Maastricht Consensus Conference, the appropriateness and diagnostic yield of upper gastrointestinal endoscopy in an open-access endoscopy system, in order to evaluate the diffusion of knowledge about Helicobacter pylori among different types of physicians. Patients undergoing endoscopy because of dyspeptic symptoms were prospectively considered in 21 endoscopy services of Campania during two different 1-week periods in 1998 and 2001. The following data were recorded: age, sex, symptoms, history of peptic ulcer with regard to previous endoscopic or radiographic examinations and treatment, endoscopic diagnosis, and H. pylori status. The indication for endoscopy was evaluated according to Maastricht guidelines and current medical knowledge. In the two periods, 1998 and 2001, 706 and 520 patients were, respectively, considered. The two series were matched for demographic characteristics, symptoms, and endoscopic diagnosis. Endoscopy was considered not indicated in 398 patients (56.4%) in 1998 and in 265 patients (50.9%) in 2001 (p = NS). The majority of them, 288/398 (72.3%) in 1998 and 162/265 (61.1%) in 2001 (p = 0.001), had recently undergone endoscopy or radiology and empiric antisecretory treatment or eradication. They had been referred to endoscopy because of recurrence of symptoms or to assess healing. In 110 cases in 1998 (27.6%) and in 103 cases in 2001 (38.9%; p = 0.001) endoscopy was performed in dyspeptic patients younger than 45 years without alarm symptoms. 4 years after the Maastricht Conference, a large number of endoscopic examinations are not indicated and could be avoided following the Maastricht guidelines. In 2001, in comparison to 1998, a larger number of physicians are likely to investigate and treat correctly the H.-pylori-related diseases, but there are still some problems with the application of the 'test-and-treat policy'. Copyright 2001 S. Karger AG, Basel

  6. ACR Appropriateness Criteria® Nonvariceal Upper Gastrointestinal Bleeding.

    PubMed

    Singh-Bhinder, Nimarta; Kim, David H; Holly, Brian P; Johnson, Pamela T; Hanley, Michael; Carucci, Laura R; Cash, Brooks D; Chandra, Ankur; Gage, Kenneth L; Lambert, Drew L; Levy, Angela D; Oliva, Isabel B; Peterson, Christine M; Strax, Richard; Rybicki, Frank J; Dill, Karin E

    2017-05-01

    Upper gastrointestinal bleeding (UGIB) remains a significant cause of morbidity and mortality with mortality rates as high as 14%. This document addresses the indications for imaging UGIB that is nonvariceal and unrelated to portal hypertension. The four variants are derived with respect to upper endoscopy. For the first three, it is presumed that upper endoscopy has been performed, with three potential initial outcomes: endoscopy reveals arterial bleeding source, endoscopy confirms UGIB without a clear source, and negative endoscopy. The fourth variant, "postsurgical and traumatic causes of UGIB; endoscopy contraindicated" is considered separately because upper endoscopy is not performed. When endoscopy identifies the presence and location of bleeding but bleeding cannot be controlled endoscopically, catheter-based arteriography with treatment is an appropriate next study. CT angiography (CTA) is comparable with angiography as a diagnostic next step. If endoscopy demonstrates a bleed but the endoscopist cannot identify the bleeding source, angiography or CTA can be typically performed and both are considered appropriate. In the event of an obscure UGIB, angiography and CTA have been shown to be equivalent in identifying the bleeding source; CT enterography may be an alternative to CTA to find an intermittent bleeding source. In the postoperative or traumatic setting when endoscopy is contraindicated, primary angiography, CTA, and CT with intravenous contrast are considered appropriate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. The European Society of Gastrointestinal Endoscopy Quality Improvement Initiative: developing performance measures.

    PubMed

    Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul

    2016-02-01

    The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision. ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients.

  8. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    PubMed

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  9. Quality Improvement in Pediatric Endoscopy: A Clinical Report From the NASPGHAN Endoscopy Committee.

    PubMed

    Kramer, Robert E; Walsh, Catharine M; Lerner, Diana G; Fishman, Douglas S

    2017-07-01

    The current era of healthcare reform emphasizes the provision of effective, safe, equitable, high-quality, and cost-effective care. Within the realm of gastrointestinal endoscopy in adults, renewed efforts are in place to accurately define and measure quality indicators across the spectrum of endoscopic care. In pediatrics, however, this movement has been less-defined and lacks much of the evidence-base that supports these initiatives in adult care. A need, therefore, exists to help define quality metrics tailored to pediatric practice and provide a toolbox for the development of robust quality improvement (QI) programs within pediatric endoscopy units. Use of uniform standards of quality reporting across centers will ensure that data can be compared and compiled on an international level to help guide QI initiatives and inform patients and their caregivers of the true risks and benefits of endoscopy. This report is intended to provide pediatric gastroenterologists with a framework for the development and implementation of endoscopy QI programs within their own centers, based on available evidence and expert opinion from the members of the NASPGHAN Endoscopy Committee. This clinical report will require expansion as further research pertaining to endoscopic quality in pediatrics is published.

  10. Training the gastrointestinal endoscopy trainer.

    PubMed

    Waschke, Kevin A; Anderson, John; Macintosh, Donald; Valori, Roland M

    2016-06-01

    Endoscopy training has traditionally been accomplished by an informal process in the endoscopy unit that parallels apprenticeship training seen in other areas of professional education. Subsequent to an audit, a series of interventions were implemented in the English National Health Service to support both service delivery and to improve endoscopy training. The resulting training centers deliver a variety of hands-on endoscopy courses, established in parallel with the roll out of a colon cancer screening program that monitors and documents quality outcomes among endoscopists. The program developed a 'training the trainer' module that subsequently became known as the Training the Colonoscopy Trainer course (TCT). Several years after its implementation, colonoscopy quality outcomes in the UK have improved substantially. The core TCT program has spread to other countries with demonstration of a marked impact on endoscopy training and performance. The aim of this chapter is to describe the principles that underlie effective endoscopy training in this program using the TCT as an example. While the review focuses on the specific example of colonoscopy training, the approach is generic to the teaching of any technical skill; it has been successfully transferred to the teaching of laparoscopic surgery as well as other endoscopic techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Remote clinical assessment of gastrointestinal endoscopy (tele-endoscopy): an initial experience.

    PubMed Central

    Kim, C. Y.; Etemad, B.; Glenn, T. F.; Mackey, H. A.; Viator, G. E.; Wallace, M. B.; Mokhashi, M. S.; Cotton, P. B.; Hawes, R. H.

    2000-01-01

    BACKGROUND: Gastrointestinal (GI) endoscopy is an effective tool to screen for cancers of the digestive tract. However, access to endoscopy is limited in many parts of South Carolina. This trial is a part of a prospective multi-part study for remote cancer screening in coastal South Carolina. This pilot study was to evaluate the quality of tele-endoscopy for cancer screening. METHODS: 10 patients scheduled for endoscopic procedures were observed simultaneously by the endoscopist and a remote observer connected over a 512 kbps ISDN line. Findings by both were compared for concordance on malignant or premalignant lesions. RESULTS: The image quality was adequate to support remote diagnosis of GI cancer and abnormal lesions by an experienced observer. However, assessment of the esophagogastric junction for Barrett's esophagus was equivocal. CONCLUSIONS: Overall, our tele-endoscopy setup shows great promise for remote supervision or observation of endoscopic procedures done by nurse endoscopists. Tele-endoscopy is both adequate and feasible for diagnosis of most gastrointestinal lesions. Subtle lesions still may be missed in our current setup. However, improvements are being made in our setup to address the problem with resolution prior to further evaluation. PMID:11079918

  12. Famous endoscopy quotes.

    PubMed

    Cappell, Mitchell S

    2012-01-01

    These quotations, whether humorous or serious, provide insight into how gastroenterology nurses, gastroenterologists, and endoscopists feel about themselves as professionals, how other healthcare professionals perceive them, and their image in popular culture. Recognition of these aspects of gastroenterology nursing, gastroenterology, and endoscopy are important for self-improvement, correcting public misperceptions, and appreciating how patient misperceptions about gastroenterology nurses and gastroenterologists and patient attitudes toward endoscopy may present barriers that gastroenterology professionals must overcome to improve patient care. These quotations also fulfill a need for witticisms during dry endoscopy lectures!

  13. Balloons and Science Kit.

    ERIC Educational Resources Information Center

    Balloon Council, Washington, DC.

    This document provides background information on balloons including: (1) the history of balloons; (2) balloon manufacturing; (3) biodegradability; (4) the fate of latex balloons; and (5) the effect of balloons on the rainforest and sea mammals. Also included as part of this instructional kit are four fun experiments that allow students to…

  14. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    NASA Astrophysics Data System (ADS)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  15. A multicenter, randomized, double-blind, placebo-controlled trial of high-dose rebamipide treatment for low-dose aspirin-induced moderate-to-severe small intestinal damage.

    PubMed

    Watanabe, Toshio; Takeuchi, Toshihisa; Handa, Osamu; Sakata, Yasuhisa; Tanigawa, Tetsuya; Shiba, Masatsugu; Naito, Yuji; Higuchi, Kazuhide; Fujimoto, Kazuma; Yoshikawa, Toshikazu; Arakawa, Tetsuo

    2015-01-01

    Low-dose aspirin (LDA) frequently causes small bowel injury. While some drugs have been reported to be effective in treating LDA-induced small intestinal damage, most studies did not exclude patients with mild damage thought to be clinically insignificant. We conducted a multicenter, randomized, double-blind, placebo-controlled trial to assess the efficacy of a high dose of rebamipide, a gastroprotective drug, for LDA-induced moderate-to-severe enteropathy. We enrolled patients who received 100 mg of enteric-coated aspirin daily for more than 3 months and were found to have more than 3 mucosal breaks (i.e., erosions or ulcers) in the small intestine by capsule endoscopy. Eligible patients were assigned to receive either rebamipide 300 mg (triple dose) 3 times daily or placebo for 8 weeks in a 2:1 ratio. Capsule endoscopy was then repeated. The primary endpoint was the change in the number of mucosal breaks from baseline to 8 weeks. Secondary endpoints included the complete healing of mucosal breaks at 8 weeks and the change in Lewis score (an endoscopic score assessing damage severity) from baseline to 8 weeks. The study was completed by 38 patients (rebamipide group: n = 25, placebo group: n = 13). After 8 weeks of treatment, rebamipide, but not placebo, significantly decreased the number of mucosal breaks (p = 0.046). While the difference was not significant (p = 0.13), the rate of complete mucosal break healing in the rebamipide group (32%, 8 of 25) tended to be higher than that in the placebo group (7.7%, 1 of 13). Rebamipide treatment significantly improved intestinal damage severity as assessed by the Lewis score (p = 0.02), whereas placebo did not. The triple dose of rebamipide was well tolerated. High-dose rebamipide is effective for the treatment of LDA-induced moderate-to-severe enteropathy. UMIN Clinical Trials Registry UMIN000003463.

  16. A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial of High-Dose Rebamipide Treatment for Low-Dose Aspirin-Induced Moderate-to-Severe Small Intestinal Damage

    PubMed Central

    Watanabe, Toshio; Takeuchi, Toshihisa; Handa, Osamu; Sakata, Yasuhisa; Tanigawa, Tetsuya; Shiba, Masatsugu; Naito, Yuji; Higuchi, Kazuhide; Fujimoto, Kazuma; Yoshikawa, Toshikazu; Arakawa, Tetsuo

    2015-01-01

    Background Low-dose aspirin (LDA) frequently causes small bowel injury. While some drugs have been reported to be effective in treating LDA-induced small intestinal damage, most studies did not exclude patients with mild damage thought to be clinically insignificant. Aim We conducted a multicenter, randomized, double-blind, placebo-controlled trial to assess the efficacy of a high dose of rebamipide, a gastroprotective drug, for LDA-induced moderate-to-severe enteropathy. Methods We enrolled patients who received 100 mg of enteric-coated aspirin daily for more than 3 months and were found to have more than 3 mucosal breaks (i.e., erosions or ulcers) in the small intestine by capsule endoscopy. Eligible patients were assigned to receive either rebamipide 300 mg (triple dose) 3 times daily or placebo for 8 weeks in a 2:1 ratio. Capsule endoscopy was then repeated. The primary endpoint was the change in the number of mucosal breaks from baseline to 8 weeks. Secondary endpoints included the complete healing of mucosal breaks at 8 weeks and the change in Lewis score (an endoscopic score assessing damage severity) from baseline to 8 weeks. Results The study was completed by 38 patients (rebamipide group: n = 25, placebo group: n = 13). After 8 weeks of treatment, rebamipide, but not placebo, significantly decreased the number of mucosal breaks (p = 0.046). While the difference was not significant (p = 0.13), the rate of complete mucosal break healing in the rebamipide group (32%, 8 of 25) tended to be higher than that in the placebo group (7.7%, 1 of 13). Rebamipide treatment significantly improved intestinal damage severity as assessed by the Lewis score (p = 0.02), whereas placebo did not. The triple dose of rebamipide was well tolerated. Conclusions High-dose rebamipide is effective for the treatment of LDA-induced moderate-to-severe enteropathy. Trial Registration UMIN Clinical Trials Registry UMIN000003463 PMID:25874951

  17. Nizatidine versus placebo in active benign gastric ulcer disease: an eight-week, multicenter, randomized, double-blind comparison. The Nizatidine Benign Gastric Ulcer Disease Study Group.

    PubMed

    Cloud, M L; Enas, N; Offen, W W

    1992-09-01

    To determine if 150 mg nizatidine twice daily or 300 mg nizatidine at bedtime are similarly effective and to compare each dose with placebo in healing benign gastric ulcers and relieving peptic ulcer symptoms. This study was a randomized, double-blind, placebo-controlled parallel comparison. The study was conducted at 74 gastroenterology and internal medicine clinics in the United States and Canada. Four hundred fifty-six patients with active benign gastric ulcer documented by endoscopy participated in the study. On the basis of a computer-generated randomization list, patients were assigned sequentially to receive either 150 mg nizatidine twice daily (n = 151), 300 mg nizatidine once daily at bedtime and identically appearing placebo capsules in the morning (n = 153), or placebo capsules twice daily (n = 152). Treatment lasted for 8 weeks unless healing was documented by endoscopy after 4 weeks. Antacid tablets (aluminum hydroxide, magnesium hydroxide, simethicone combination) were supplied for relief of symptoms. Both doses of nizatidine significantly improved healing rates at 8 weeks compared with placebo. Daytime and nighttime symptom severity was improved by both nizatidine regimens at end point (p less than 0.015 versus placebo, two-tailed test). Antacid use was similar for all groups in the end point analysis. Patient well-being was significantly better in patients treated with nizatidine than in patients in the placebo group ((p less than 0.04, two-tailed test). No clinically significant differences in the incidence of adverse clinical or laboratory events were noted. Nizatidine, 300 mg at bedtime and 150 mg twice daily, resulted in greater healing of benign gastric ulcers than placebo treatment after 8 weeks. Relief of the symptoms of gastric ulcer was significantly better in the patients receiving nizatidine treatment versus placebo treatment.

  18. Pravastatin and endothelium dependent vasomotion after coronary angioplasty: the PREFACE trial.

    PubMed

    Mulder, H J; Schalij, M J; Kauer, B; Visser, R F; van Dijkman, P R; Jukema, J W; Zwinderman, A H; Bruschke, A V

    2001-11-01

    To test the hypothesis that the 3-hydroxy-3-methylglutaryl coenzyme-A reductase inhibitor pravastatin ameliorates endothelium mediated responses of dilated coronary segments: the PREFACE (pravastatin related effects following angioplasty on coronary endothelium) trial. A double blind, randomised, placebo controlled, multicentre study. Four hospitals in the Netherlands. 63 non-smoking, non-hypercholesterolaemic patients scheduled for elective balloon angioplasty (pravastatin 34, placebo 29). The effects of three months of pravastatin treatment (40 mg daily) on endothelium dependent vasomotor function were studied. Balloon angioplasty was undertaken one month after randomisation, and coronary vasomotor function tests using acetylcholine were performed two months after balloon angioplasty. The angiograms were analysed quantitatively. The efficacy measure was the acetylcholine induced change in mean arterial diameter, determined in the dilated segment and in an angiographically normal segment of an adjacent non-manipulated coronary artery. Increasing acetylcholine doses produced vasoconstriction in the dilated segments (p = 0.004) but not in the normal segments. Pravastatin did not affect the vascular response to acetylcholine in either the dilated segments (p = 0.09) or the non-dilated sites. Endothelium dependent vasomotion in normal segments was correlated with that in dilated segments (r = 0.47, p < 0.001). There were fewer procedure related events in the pravastatin group than in the placebo group (p < 0.05). Endothelium dependent vasomotion in normal segments is correlated with that in dilated segments. A significant beneficial effect of pravastatin on endothelial function could not be shown, but in the dilated segments there was a trend towards a beneficial treatment effect in the pravastatin group.

  19. Countermeasures to the US National Missile Defense

    NASA Astrophysics Data System (ADS)

    Gronlund, Lisbeth

    2001-04-01

    One of the key technical questions about national missile defenses is whether they can be expected to work under real-world conditions if the attacker takes steps to defeat the defense. This talk will discuss steps that an emerging missile state could take to confuse, overwhelm, or otherwise defeat the planned US NMD system developed by the Clinton administration. It will consider three such ``countermeasures" that would be within the technical capability of a state that could develop and deploy a long-range missile capable of reaching the United States, which is the threat the NMD system is intended to defend against. The talk will be based on the April 2000 report ``Countermeasures: A Technical Evaluation of the Operational Effectiveness of the Planned US National Missile Defense System," which was co-authored by the speaker and 10 other physicists and engineers. Although the talk will refer to the ground-based NMD system under development, the conclusions are applicable to any mid-course NMD system using hit-to-kill infrared-homing interceptors, regardless of their basing mode. The three countermeasures considered are: (1) biological weapons deployed on 100 or more small bomblets, or submunitions, that would be released shortly after the boost phase; (2) nuclear warheads with anti-simulation balloon decoys, in which the attacker disguises the warhead by enclosing it in an aluminum-coated mylar balloon and releasing it along with a large number of otherwise similar but empty balloons; and (3) nuclear warheads with cooled shrouds, in which the attacker foils the kill vehicle's homing process by covering each nuclear warhead with a double-walled cone containing liquid nitrogen.

  20. Microwave endometrial ablation versus thermal balloon endometrial ablation (MEATBall): 5-year follow up of a randomised controlled trial.

    PubMed

    Sambrook, A M; Elders, A; Cooper, K G

    2014-05-01

    To compare long-term outcomes following microwave endometrial ablation (MEA™) and thermal balloon ablation (TBall). Follow up of a prospective, double-blind randomised controlled trial at 5 years. A teaching hospital in the UK. A total of 320 women eligible for and requesting endometrial ablation. Eligible women were randomised in a 1:1 ratio to undergo MEA or Tball. Postal questionnaires were sent to participants at a minimum of 5 years postoperatively to determine satisfaction with outcome, menstrual status, bleeding scores and quality of life measurement. Subsequent surgery was ascertained from the women and the hospital operative database. The primary outcome measure was overall satisfaction with treatment. Secondary outcomes included evaluation of menstrual loss, change in quality of life scores and subsequent surgery. Of the women originally randomised 217/314 (69.1%) returned questionnaires. Nonresponders were assumed to be treatment failures for data analysis. The primary outcome of satisfaction was similar in both groups (58% for MEA™ versus 53% for TBall, difference 5%; 95% CI -6 to 16%). Amenorrhoea rates were high following both techniques (51% versus 45%, difference 6%; 95% CI -5 to 17%). There was no significant difference in the hysterectomy rates between the two arms (9% versus 7%, difference 2%; 95% CI -5 to 9%). At 5 years post-treatment there were no significant clinical differences in patient satisfaction, menstrual status, quality of life scores or hysterectomy rates between MEA™ and Thermachoice 3, thermal balloon ablation. © 2014 Royal College of Obstetricians and Gynaecologists.

  1. Analysis of actinic flux profiles measured from an ozonesonde balloon

    NASA Astrophysics Data System (ADS)

    Wang, P.; Allaart, M.; Knap, W. H.; Stammes, P.

    2015-04-01

    A green light sensor has been developed at KNMI to measure actinic flux profiles using an ozonesonde balloon. In total, 63 launches with ascending and descending profiles were performed between 2006 and 2010. The measured uncalibrated actinic flux profiles are analysed using the Doubling-Adding KNMI (DAK) radiative transfer model. Values of the cloud optical thickness (COT) along the flight track were taken from the Spinning Enhanced Visible and Infrared Imager (SEVIRI) Cloud Physical Properties (CPP) product. The impact of clouds on the actinic flux profile is evaluated on the basis of the cloud modification factor (CMF) at the cloud top and cloud base, which is the ratio between the actinic fluxes for cloudy and clear-sky scenes. The impact of clouds on the actinic flux is clearly detected: the largest enhancement occurs at the cloud top due to multiple scattering. The actinic flux decreases almost linearly from cloud top to cloud base. Above the cloud top the actinic flux also increases compared to clear-sky scenes. We find that clouds can increase the actinic flux to 2.3 times the clear-sky value at cloud top and decrease it to about 0.05 at cloud base. The relationship between CMF and COT agrees well with DAK simulations, except for a few outliers. Good agreement is found between the DAK-simulated actinic flux profiles and the observations for single-layer clouds in fully overcast scenes. The instrument is suitable for operational balloon measurements because of its simplicity and low cost. It is worth further developing the instrument and launching it together with atmospheric chemistry composition sensors.

  2. Distension of the esophagogastric junction augments triggering of transient lower esophageal sphincter relaxation.

    PubMed

    van Wijk, Michiel P; Blackshaw, L Ashley; Dent, John; Benninga, Marc A; Davidson, Geoffrey P; Omari, Taher I

    2011-10-01

    Patients with gastroesophageal reflux disease show an increase in esophagogastric junction (EGJ) distensibility and in frequency of transient lower esophageal sphincter relaxations (TLESR) induced by gastric distension. The objective was to study the effect of localized EGJ distension on triggering of TLESR in healthy volunteers. An esophageal manometric catheter incorporating an 8-cm internal balloon adjacent to a sleeve sensor was developed to enable continuous recording of EGJ pressure during distension of the EGJ. Inflation of the balloon doubled the cross-section of the trans-sphincteric portion of the catheter from 5 mm OD (round) to 5 × 11 mm (oval). Ten healthy subjects were included. After catheter placement and a 30-min adaptation period, the EGJ was randomly distended or not, followed by a 45-min baseline recording. Subjects consumed a refluxogenic meal, and recordings were made for 3 h postprandially. A repeat study was performed on another day with EGJ distension status reversed. Additionally, in one subject MRI was performed to establish the exact position of the balloon in the inflated state. The number of TLESR increased during periods of EGJ distension with the effect being greater after a meal [baseline: 2.0(0.0-4.0) vs. 4.0(1.0-11.0), P=0.04; postprandial: 15.5(10.0-33.0) vs. 22.0(17.0-58.0), P=0.007 for undistended and distended, respectively]. EGJ distension augments meal-induced triggering of TLESR in healthy volunteers. Our data suggest the existence of a population of vagal afferents located at sites in/around the EGJ that may influence triggering of TLESR.

  3. Terahertz photometers to observe solar flares from space (SOLAR-T project)

    NASA Astrophysics Data System (ADS)

    Kaufmann, Pierre; Raulin, Jean-Pierre

    The space experiment SOLAR-T designed to observe solar flares at THz frequencies was completed. We present the concept, fabrication and performance of a double THz photometers system. An innovative optical setup allows observations of the full solar disk and the detection of small burst transients at the same time. It is the first detecting system conceived to observe solar flare THz emissions on board of stratospheric balloons. The system has been integrated to data acquisition and telemetry modules for this application. SOLAR-T uses two Golay cell detectors preceded by low-pass filters made of rough surface primary mirrors and membranes, 3 and 7 THz band-pass filters, and choppers. Its photometers can detect small solar bursts (tens of solar flux units) with sub second time resolution. One artificial Sun setup was developed to simulate actual observations. Tests comprised the whole system performance, on ambient and low pressure and temperature conditions. It is intended to provide data on the still unrevealed spectral shape of the mysterious THz solar flares emissions. The experiment is planned to be on board of two long-duration stratospheric balloon flights over Antarctica and Russia in 2014-2016. The SOLAR-T development, fabrication and tests has been accomplished by engineering and research teams from Mackenzie, Unicamp and Bernard Lyot Solar Observatory; Propertech Ltda.; Neuron Ltda.; and Samsung, Brazil; Tydex LCC, Russia; CONICET, Argentina; the stratospheric balloon missions will be carried in cooperation with teams from University of California, Berkeley, USA (flight over Antarctica), and Lebedev Physical Institute, Moscow, Russia (flight over Russia).

  4. Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.

    PubMed

    Ro, Andrew J; Davé, Vipul

    2013-03-01

    Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. A stress index model for ascending balloons

    NASA Technical Reports Server (NTRS)

    Smith, I. S.

    1986-01-01

    Attention is given to the development on the part of NASA of a simplified stress 'index' model to establish the relative stress magnitudes along a balloon's gore position as a function of altitude. Application of this model to several hundred balloon flights showed a good correlation between balloon failure rate and stress 'index' level. This model can be used during the balloon design process to lower the levels of stress in the balloon. By increasing the wall thickness of the balloon, adding caps, lengthening caps, or using external caps, lower stress can be accomplished. As a result, in January 1985, the NASA Balloon Program established a stress index specification to limit the design and flight stresses for NASA balloons.

  6. Ethical aspects of capsule endoscopy.

    PubMed

    Niv, Yaron

    2008-01-01

    Capsule endoscopy is the most recent innovation in gastrointestinal endoscopy. The capsule contains a video camera that photographs the bowel for 8 h after the capsule has been orally ingested and transmits the images for interpretation to a computerized workstation. Ethical considerations of the use of capsule endoscopy should cover the following main issues: justification of the procedure, its potential benefits and harm, and patient autonomy. Capsule endoscopy has several advantages over traditional endoscopy. The procedure is painless, does not require sedation, is easy to perform and for the first time enables exploration of the entire small bowel at high magnification. However, the clinician cannot control its passive advance along the bowel. In addition, the examination may be incomplete, as the capsule reaches the cecum in only 80% of cases. This paper discusses the problems related to the new endoscopic procedure, the diagnostic yield in comparison with other procedures, proper indications for the procedure, outcome and complications. Copyright 2008 S. Karger AG, Basel.

  7. Simethicone for small bowel preparation for capsule endoscopy: a systematic, single-blinded, controlled study.

    PubMed

    Albert, Jörg; Göbel, Christa-Maria; Lesske, Joachim; Lotterer, Erich; Nietsch, Hubert; Fleig, Wolfgang E

    2004-04-01

    Capsule endoscopy is a new imaging method for visualization of the entire small bowel. However, no standardized protocol for bowel preparation for capsule endoscopy has been evaluated. Capsule endoscopy was performed in 36 consecutive patients, all of whom fasted for 12 hours before ingestion of the capsule. Before capsule endoscopy, 18 patients received 80 mg simethicone and 18 had no supplemental medication for bowel preparation. Two observers, both experienced endoscopists, independently reviewed the examinations in a single-blinded and randomly assigned fashion. Mucosal visibility and intraluminal gas bubbles were assessed and graded by both observers. Bowel preparation with simethicone resulted in significantly better visibility because of fewer intraluminal bubbles (p<0.01). Interobserver agreement was excellent (r>/=0.8; k 0.78: 95% CI[0.57, 0.98] ). No adverse effect of simethicone was observed. Simethicone may be added to the routine preparation for capsule endoscopy to improve the visibility of small bowel mucosa.

  8. Effect of routine rapid insertion of Bakri balloon tamponade on reducing hemorrhage from placenta previa during and after cesarean section.

    PubMed

    Soyama, Hiroaki; Miyamoto, Morikazu; Sasa, Hidenori; Ishibashi, Hiroki; Yoshida, Masashi; Nakatsuka, Masaya; Takano, Masashi; Furuya, Kenichi

    2017-09-01

    To evaluate the effectiveness of routine rapid insertion of a Bakri balloon during cesarean section for placenta previa based on a retrospective control study. Women with singleton pregnancies who underwent cesarean section for placenta previa at our institution between 2003 and 2016 were enrolled. Between 2015 and 2016, women who routinely underwent balloon tamponade during cesarean section were defined as the balloon group. Between 2003 and 2014, women who underwent no hemostatic procedures except balloon tamponade were defined as the non-balloon group. The clinical outcomes of the two groups were retrospectively analyzed. Of the 266 women with placenta previa, 50 were in the balloon group and 216 were in the non-balloon group. The bleeding amounts were significantly smaller in the balloon group than in the non-balloon group: intraoperative bleeding (991 vs. 1250 g, p < 0.01), postoperative bleeding (62 vs. 150 g, p < 0.01), and total bleeding (1066 vs. 1451 g, p < 0.01). Furthermore, the mean surgical duration was shorter in the balloon group than the non-balloon group (30 vs. 50 min, p < 0.01). In the balloon group, five patients suffered from increasing hemorrhage due to prolapse of the balloon from the uterus after the operation, but the hemorrhage was controlled by balloon re-insertion without additional hemostatic procedures. This study demonstrated that the routine rapid insertion of Bakri balloon tamponade during cesarean section significantly decreased intra- and postoperative hemorrhage and shortened the surgical duration in women with placenta previa.

  9. Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis

    PubMed Central

    Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron

    2015-01-01

    Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. Limitations The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. Conclusions The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system. PMID:26366240

  10. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  11. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  12. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  13. Status of the NASA Balloon Program

    NASA Astrophysics Data System (ADS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  14. Job Stress and Job Satisfaction among Health-Care Workers of Endoscopy Units in Korea

    PubMed Central

    Nam, Seung-Joo; Chun, Hoon Jai; Moon, Jeong Seop; Park, Sung Chul; Hwang, Young-Jae; Yoo, In Kyung; Lee, Jae Min; Kim, Seung Han; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-01-01

    Background/Aims: The management of job-related stress among health-care workers is critical for the improvement of healthcare services; however, there is no existing research on endoscopy unit workers as a team. Korea has a unique health-care system for endoscopy unit workers. In this study, we aimed to estimate job stress and job satisfaction among health-care providers in endoscopy units in Korea. Methods: We performed a cross-sectional survey of health-care providers in the endoscopy units of three university-affiliated hospitals in Korea. We analyzed the job stress levels by using the Korean occupational stress scale, contributing factors, and job satisfaction. Results: Fifty-nine workers completed the self-administered questionnaires. The job stress scores for the endoscopy unit workers (46.39±7.81) were relatively lower compared to those of the national sample of Korean workers (51.23±8.83). Job stress differed across job positions, with nurses showing significantly higher levels of stress (48.92±7.97) compared to doctors (42.59±6.37). Job stress and job satisfaction were negatively correlated with each other (R2=0.340, p<0.001). Conclusions: An endoscopy unit is composed of a heterogeneous group of health-care professionals (i.e., nurses, fellows, and professors), and job stress and job satisfaction significantly differ according to job positions. Job demand, insufficient job control, and job insecurity are the most important stressors in the endoscopy unit. PMID:26898513

  15. Job Stress and Job Satisfaction among Health-Care Workers of Endoscopy Units in Korea.

    PubMed

    Nam, Seung-Joo; Chun, Hoon Jai; Moon, Jeong Seop; Park, Sung Chul; Hwang, Young-Jae; Yoo, In Kyung; Lee, Jae Min; Kim, Seung Han; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-05-01

    The management of job-related stress among health-care workers is critical for the improvement of healthcare services; however, there is no existing research on endoscopy unit workers as a team. Korea has a unique health-care system for endoscopy unit workers. In this study, we aimed to estimate job stress and job satisfaction among health-care providers in endoscopy units in Korea. We performed a cross-sectional survey of health-care providers in the endoscopy units of three university-affiliated hospitals in Korea. We analyzed the job stress levels by using the Korean occupational stress scale, contributing factors, and job satisfaction. Fifty-nine workers completed the self-administered questionnaires. The job stress scores for the endoscopy unit workers (46.39±7.81) were relatively lower compared to those of the national sample of Korean workers (51.23±8.83). Job stress differed across job positions, with nurses showing significantly higher levels of stress (48.92±7.97) compared to doctors (42.59±6.37). Job stress and job satisfaction were negatively correlated with each other (R (2) =0.340, p<0.001). An endoscopy unit is composed of a heterogeneous group of health-care professionals (i.e., nurses, fellows, and professors), and job stress and job satisfaction significantly differ according to job positions. Job demand, insufficient job control, and job insecurity are the most important stressors in the endoscopy unit.

  16. Validation of the Capsule Endoscopy Crohn's Disease Activity Index (CECDAI or Niv score): a multicenter prospective study.

    PubMed

    Niv, Y; Ilani, S; Levi, Z; Hershkowitz, M; Niv, E; Fireman, Z; O'Donnel, S; O'Morain, C; Eliakim, R; Scapa, E; Kalantzis, N; Kalantzis, C; Apostolopoulos, P; Gal, E

    2012-01-01

    The Capsule Endoscopy Crohn's Disease Activity Index (CECDAI or Niv score) was devised to measure mucosal disease activity using video capsule endoscopy (VCE). The aim of the current study was to prospectively validate the use of the scoring system in daily practice. This was a multicenter, double-blind, prospective, controlled study of VCE videos from 62 consecutive patients with isolated small-bowel Crohn's disease. The CECDAI was designed to evaluate three main parameters of Crohn's disease: inflammation (A), extent of disease (B), and stricture (C), in both the proximal and distal segments of the small bowel. The final score was calculated by adding the two segmental scores: CECDAI = ([A1 × B1] + C1) + ([A2 × B2] + C2). Each examiner in every site interpreted 6 - 10 videos and calculated the CECDAI. The de-identified CD-ROMs were then coded and sent to the principal investigator for CECDAI calculation. The cecum was reached in 72 % and 86 % of examinations, and proximal small-bowel involvement was found in 56 % and 62 % of the patients, according to the site investigators and principal investigator, respectively. Significant correlation was demonstrated between the calculation of the CECDAI by the individual site investigators and that performed by the principal investigator. Overall correlation between endoscopists from the different study centers was good, with r = 0.767 (range 0.717 - 0.985; Kappa 0.66; P < 0.001). There was no correlation between the CECDAI and the Crohn's Disease Activity Index or the Inflammatory Bowel Disease Quality of Life Questionnaire or any of their components. A new scoring system of mucosal injury in Crohn's disease of the small intestine, the CECDAI, was validated. Its use in controlled trials and/or regular follow-up of these patients is advocated. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Evolution of scientific ballooning and its impact on astrophysics research

    NASA Astrophysics Data System (ADS)

    Jones, William Vernon

    2014-05-01

    As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.

  18. Investigation of hot air balloon fatalities.

    PubMed

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  19. Scientific Ballooning Activities and Recent Developments in Technology and Instrumentation of the TIFR Balloon Facility, Hyderabad

    NASA Astrophysics Data System (ADS)

    Buduru, Suneel Kumar

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.

  20. Double- vs. single-balloon enteroscopy: single center experience with emphasis on procedural performance.

    PubMed

    Lenz, Philipp; Roggel, Moritz; Domagk, Dirk

    2013-09-01

    This study aims to compare double- (DBE) and single-balloon enteroscopy (SBE) in small bowel disorders with respect to procedural performance and clinical impact. This retrospective analysis at a tertial referral center included 1,052 DBEs and 515 SBEs performed in 904 patients over 7 years. Procedural and patients' characteristics were precisely analyzed. Significantly more patients with anemia and gastrointestinal bleeding were investigated by DBE (P < 0.01). Oral insertion depth and length of investigated small bowel in the combined approach were significantly higher in the DBE compared to the SBE group (245 ± 65.3 vs. 218 ± 62.6 and 355 ± 101.9 vs. 319 ± 91.2, respectively; P < 0.001, each). By analyzing only recent years of enteroscopy (2008-2011), no difference in small bowel visualization could be observed. The anal insertion depths and complete enteroscopy rates (CER) were comparable. Procedure times were significantly shorter within the SBE procedure (oral: 50 vs. 40 min; anal: 55 vs. 46 min, P < 0.001) and the usage of sedation was significantly less (propofol: P < 0.001; pethidine: P < 0.05). Diagnostic yield was significantly higher in the SBE, compared to the DBE group (61.7 vs. 48.2 %; P < 0.001). The rate of severe adverse events was close to zero. Both enteroscopy techniques are safe diagnostic tools and proved to be indispensable in the daily gastroenterological practice. The lower insertion depths, but higher diagnostic yield, of SBE may reflect the more focused selection of patients scheduled for small bowel diagnostics in recent years.

  1. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    PubMed

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  2. Use of monorail PTCA balloon catheter for local drug delivery.

    PubMed

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  3. Retained Capsule Endoscope.

    PubMed

    Aihole, Jayalaxmi S; Vishnumurthy, G S; Babu, M Narendra

    2016-11-15

    Capsule endoscopy was invented to visualize the entire small intestine in a non- invasive manner in adults. 1 y, 9 mo-old boy presented with generalized edema for last 3 months. His routine investigations, including the upper gastrointestinal endoscopy, colonoscopy, and contrast enhanced computed tomography scan (CECT) were normal. In view of clinical suspicion of protein losing enteropathy, we planned capsule endoscopy. The capsule was not passed even after 3 weeks. Laparoscopy revealed impacted capsule in a dilated intestinal loop proximal to an ileal stricuture. Capsule endoscopy should be used judiciously in children.

  4. The European Society of Gastrointestinal Endoscopy Quality Improvement Initiative: developing performance measures.

    PubMed

    Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul

    2016-01-01

    The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision.ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers

    PubMed Central

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-01-01

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology. PMID:26361416

  6. Abdominal compression during endoscopy (the Bolster technique) demonstrates hidden Schatzki rings (with videos).

    PubMed

    Jouhourian, Caroline; Bonis, Peter A; Guelrud, Moises

    2016-05-01

    Schatzki rings are found in the distal esophagus, are associated with hiatal hernias, and present with intermittent dysphagia to solid foods. They can be identified by radiology (GI series or barium swallow studies) or endoscopy. Rings are not always visualized during endoscopy in patients in whom they are suspected clinically. The Bolster technique involves application of epigastric abdominal pressure, which offers the potential to reveal a Schatzki ring that is otherwise obscured within a reduced hiatal hernia. The aim of this study was to determine whether the Bolster technique improves endoscopic detection of Schatzki rings. We reviewed 30 symptomatic patients with a history of a Schatzki ring in a tertiary care center. The Bolster technique was applied to patients in whom the ring was not visible during standard endoscopy. The main outcome measurement was identification of the Schatzki ring after the Bolster technique. A Schatzki ring was visible during standard endoscopy in 26 of the 30 patients. In the remaining 4, the ring was visible only after the application of the Bolster technique. The Bolster technique is a simple maneuver that can increase detection rates of Schatzki rings during endoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. [Management of open access gastrointestinal endoscopy and quality of care: collaboration between an improvement team and primary care].

    PubMed

    Sebastián Domingo, Juan José; Sánchez Sánchez, Clara; Galve Royo, Eugenio; Mendi Metola, Carolina; Valdepérez Torrubia, Javier

    2012-02-01

    To create an improvement team within a healthcare quality improvement project of the Government of Aragon (Spain), aimed at increasing the quality of care and suitability of the indications of gastrointestinal endoscopy in the open access endoscopy system of a secondary hospital in Aragon. The team developed a consensus document indicating how to use oral endoscopy and colonoscopy correctly, and held information and training sessions with all the primary care physicians involved in this area. Sector I health centers and Royo Villanova Hospital, in Zaragoza. The team consisted of a gastroenterologist and three primary care physicians and, from the outset received the support of the primary care administration and management in the health area. Inappropriate use of endoscopy, particularly colonoscopy, was reduced from 20% to 11.6%. Significant savings were achieved in health costs. The endoscopy waiting list was reduced. The quality of care and the safety of patients undergoing these examinations improved. Training of primary care physicians in these procedures was enhanced, and coordination between primary and specialized was implemented. To ensure efficient running of an open access gastrointestinal endoscopy system, an interdisciplinary improvement team and the full involvement of the primary care staff managing this resource are required. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  8. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers.

    PubMed

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-09-07

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology.

  9. Hot-Air Ballooning in Physics Teaching.

    ERIC Educational Resources Information Center

    Haugland, Ole Anton

    1991-01-01

    Describes the modern hot-air balloon and the physics of ballooning. Proposes that students construct their own hot-air balloon and presents an experiment calculating the time needed for a balloon to rise to the ceiling of a gymnasium. (MDH)

  10. Air Force Cambridge Research Laboratories balloon operations

    NASA Technical Reports Server (NTRS)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  11. Histopathologic findings in children diagnosed with cow's milk protein allergy.

    PubMed

    Cervantes-Bustamante, R; Pedrero-Olivares, I; Toro-Monjaraz, E M; Murillo-Márquez, P; Ramírez-Mayans, J A; Montijo-Barrios, E; Zárate-Mondragón, F; Cadena-León, J; Cazares-Méndez, M; López-Ugalde, M

    2015-01-01

    Cow's milk protein allergy is the most common cause of food allergy. The challenge test, either open or doubled-blind with a placebo control, is regarded as the criterion standard. Endoscopy and histologic findings are considered a method that can aid in the diagnosis of this entity. The aim of this study was to describe the histopathologic findings in children suspected of cow's milk protein allergy that were seen at our hospital. A descriptive, observational study was conducted on 116 children clinically suspected of presenting with cow's milk protein allergy that were seen at the Department of Gastroenterology and Nutrition of the Instituto Nacional de Pediatría. Upper endoscopy and rectosigmoidoscopy with biopsies were performed and the findings were described. Of the 116 patients, 64 (55.17%) were girls and 52 (44.83%) were boys. The rectum was the site with the greatest presence of eosinophils per field in both groups, followed by the duodenum. In general, more than 15 eosinophils were found in 46% of the patients. Between 40 and 45% of the cases had the histologic criterion of more than 15 to 20 eosinophils per field and the rectosigmoid colon was the most affected site. Therefore, panendoscopy and rectosigmoidoscopy with biopsy and eosinophil count are suggested. Copyright © 2014 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  12. Status of Competency-Based Medical Education in Endoscopy Training: A Nationwide Survey of US ACGME-Accredited Gastroenterology Training Programs.

    PubMed

    Patel, S G; Keswani, R; Elta, G; Saini, S; Menard-Katcher, P; Del Valle, J; Hosford, L; Myers, A; Ahnen, D; Schoenfeld, P; Wani, S

    2015-07-01

    The Accreditation Council for Graduate Medical Education (ACGME) emphasizes the importance of medical trainees meeting specific performance benchmarks and demonstrating readiness for unsupervised practice. The aim of this study was to examine the readiness of Gastroenterology (GI) fellowship programs for competency-based evaluation in endoscopic procedural training. ACGME-accredited GI program directors (PDs) and GI trainees nationwide completed an online survey of domains relevant to endoscopy training and competency assessment. Participants were queried about current methods and perceived quality of endoscopy training and assessment of competence. Participants were also queried about factors deemed important in endoscopy competence assessment. Five-point Likert items were analyzed as continuous variables by an independent t-test and χ(2)-test was used for comparison of proportions. Survey response rate was 64% (94/148) for PDs and 47% (546/1,167) for trainees. Twenty-three percent of surveyed PDs reported that they do not have a formal endoscopy curriculum. PDs placed less importance (1—very important to 5—very unimportant) on endoscopy volume (1.57 vs. 1.18, P<0.001), adenoma detection rate (2.00 vs. 1.53, P<0.001), and withdrawal times (1.96 vs. 1.68, P=0.009) in determining endoscopy competence compared with trainees. A majority of PDs report that competence is assessed by procedure volume (85%) and teaching attending evaluations (96%). Only a minority of programs use skills assessment tools (30%) or specific quality metrics (28%). Specific competencies are mostly assessed by individual teaching attending feedback as opposed to official documentation or feedback from a PD. PDs rate the overall quality of their endoscopy training and assessment of competence as better than overall ratings by trainees. Although the majority of PDs and trainees nationwide believe that measuring specific metrics is important in determining endoscopy competence, most programs still rely on procedure volume and subjective attending evaluations to determine overall competence. As medical training transitions from an apprenticeship model to competency-based education, there is a need for improved endoscopy curricula which are better suited to demonstrate readiness for unsupervised practice.

  13. The role of a nurse telephone call to prevent no-shows in endoscopy.

    PubMed

    Childers, Ryan E; Laird, Amy; Newman, Lisa; Keyashian, Kian

    2016-12-01

    Preventing missed appointments, or "no-shows," is an important target in improving efficient patient care and lowering costs in gastrointestinal endoscopy practices. We aimed to investigate whether a nurse telephone call would reduce no-show rates for endoscopic appointments, and to determine if hiring and maintaining a nurse dedicated to pre-endoscopy phone calls is economically advantageous. Our secondary aim was to identify predictors of no-shows to endoscopy appointments. We hired and trained a full-time licensed nurse to make a telephone call to patients 7 days before their scheduled upper endoscopy or colonoscopy. We compared this intervention with a previous reminder system involving mailed reminders. The effect of the intervention and impact of other predictors of no-shows were analyzed in 2 similar preintervention and postintervention patient cohorts. A mixed effects logistic regression model was used to estimate the association of the odds of being a no-show to the scheduled appointment and the characteristics of the patient and visit. An analysis of costs was performed that included the startup and maintenance costs of the intervention. We found that a nurse phone call was associated with a 33% reduction in the odds of a no-show visit (odds ratio, 0.67; 95% confidence interval, 0.50-0.91), adjusting for gender, age, partnered status, insurer type, distance from the endoscopy center, and visit type. The recovered reimbursement during the study period was $48,765, with net savings of $16,190 when accounting for the maintenance costs of the intervention; this resulted in a net revenue per annum of $43,173. We found that endoscopy practices may increase revenue, improve scheduling efficiency, and maximize resource utilization by hiring a nurse to reduce no-shows. Predictors of no-shows to endoscopy included unpartnered or single patients, commercial or managed care, being scheduled for colonoscopy as opposed to upper endoscopy, and being scheduled for a screening or surveillance colonoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  14. Development of a Super-Pressure Balloon with an Improved Design

    NASA Astrophysics Data System (ADS)

    Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya

    A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.

  15. Radiation Budget Profiles measured through the Atmosphere with a Return Glider Radiosonde

    NASA Astrophysics Data System (ADS)

    Philipona, R.; Kraeuchi, A.; Kivi, R.

    2015-12-01

    Very promising radiation budget profile measurements through the atmosphere were made in 2011 with a balloon borne short- and longwave net radiometer. New and improved radiation sensors from Kipp&Zonen are now used in a glider aircraft together with a standard Swiss radiosonde from Meteolabor AG. This new return glider radiosonde (RG-R), is lifted up with double balloon technique to prevent pendulum motion and to keep the radiation instruments as horizontal as possible during the ascent measuring phase. The RG-R is equipped with a release mechanism and an autopilot that flies the glider radiosonde back to the launch site, or to a predefined open space, where it releases a parachute for landing once it is 100 meter above ground. The RG-R was successfully tested and deployed for tropospheric and stratospheric radiation measurements up to 30 hPa (24 km altitude) at the GRUAN sites Payerne (Switzerland) and Sodankylä (Finland). Radiation profiles and the radiation budget through the atmosphere during different daytimes and under cloud-free and cloudy situations will be shown in relation to temperature and humidity at the surface and in the atmosphere. The RG-R flight characteristics and new measurement possibilities will also be discussed.

  16. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate the learning curve for endoscopy training.

    PubMed

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-03-01

    Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists⁄surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The 'Endoscopy Task Load Index' was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers.

  17. Contact Endoscopy of mucosal lesions of oral cavity – Preliminary experience

    PubMed Central

    Mishra, Awadhesh Kumar; Nilakantan, Ajith; Sahai, Kavita; Datta, Rakesh; Malik, Ajay

    2014-01-01

    Background Contact Endoscopy is a non invasive tool to visualise alterations in cell architecture in vivo. In this study we investigated the diagnostic accuracy of Contact Endoscopy in detecting malignancy in oral mucosal lesions. Methods 76 patients with oral mucosal lesions requiring biopsy were included. Contact Endoscopy was performed by Otolaryngologist before biopsy and findings recorded. The lesion was then biopsied and sent for histopathological examination by Pathologist who was blinded to Contact Endoscopy findings. Findings of Contact Endoscopy were compared with histopathological findings taking the latter as the gold standard. Two biopsies were reported as ‘inconclusive’ on histopathological examination and hence excluded from the final analysis. Data of the remaining 74 patients is presented here. Results Clinically lesions were diagnosed as ulcero-proliferative lesions in 34 patients, Leukoplakia in 19, Erythroplakia in 9, Lichen planus in 5 and Submucous fibrosis in 7 patients. Histopathological examination revealed presence of malignancy in 97.06% of ulcero-proliferative mucosal lesions, 10.53% of leukoplakia and 33.33% of erythroplakia while corresponding figures on Contact Endoscopy were 94.12%, 5.26% and 11.11% respectively. No malignancy was detected in lichen planus and submucous fibrosis by either technique. When compared with histopathological examination, CE showed sensitivity of 84.21%, specificity of 94.44% and accuracy of 89.19%. No adverse effects on the patients were seen due to the procedure or stain. Conclusion Contact Endoscopy may be useful in determining cellular structure in vivo without biopsy to detect oral malignancy early. Further studies are suggested. PMID:25378780

  18. Development of a 5,000 m(3) super-pressure balloon with a diamond-shaped net

    NASA Astrophysics Data System (ADS)

    Saito, Yoshitaka; Tanaka, Shigeki; Nakashino, Kyoichi; Matsushima, Kiyoho; Goto, Ken; Furuta, Ryosuke; Domoto, Kodai; Akita, Daisuke; Hashimoto, Hiroyuki

    A light super-pressure balloon of which weight will be comparable to the weight of the zero-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m(3) balloon. A flight test of a 3,000 m(3) balloon in the tandem balloon configuration with a 15,000 m(3) zero-pressure balloon was performed in 2012. Although a small gas leak occurred in the super-pressure balloon at the differential pressure of 400 to 500 Pa, the differential pressure reached the highest value of 814 Pa and kept positive through the level flight lasting for 25 minutes due to its slow leakage. To avoid a possible stress concentration to films at the polar area, a new design setting the meridian length of the balloon gore film equal to the length of the net was adopted. A 3-m balloon with the design was developed and its capacity to resist pressure at room temperature and at -30 (°) C was checked through the ground inflation tests. In 2013, a balloon of the same model was launched in the tandem balloon configuration with 2 kg rubber balloons. It was confirmed that the balloon could withstand the maximum differential pressure of 6,280 Pa, could withstand the differential pressure of 5,600 Pa for 2 hours, and there was a small gas leak through a hole with an area of 0.4 mm(2) which was also found in the ground leakage test. These results indicated that the improvement was adequate and there was no problem for the super-pressure balloon to fly in the environment of the stratosphere except for the problem of the small gas leak. In 2014, a flight test of a 5,000 m(3) balloon will be performed. In this paper, after reviewing the method to cover a balloon with a diamond-shaped net, the current status of the development will be reported.

  19. Flight Qualification of the NASA's Super Pressure Balloon

    NASA Astrophysics Data System (ADS)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test flight by successfully demonstrated balloon vehicle performance, obtained a large amount of videos, measured balloon differential pressure, obtained temperature and altitude data, assessed structure strength through pressurization, and demonstrated the balloon vehicles altitude stability. This flight was the first of several to qualify this design for the science community. Results of the most recent flights will be presented. Some of the related material characterization testing which is vital to the balloon design development for the balloon will also be presented. Additionally, this paper will provide a current overview of the development and qualification approach pursued for the NASA’s Super Pressure Balloon. Future plans and goals of future test flights will also be presented. This will include the projected balloon volumes, payload capabilities, test flight locations, and proposed flight schedule.

  20. Virtual reality simulators for gastrointestinal endoscopy training

    PubMed Central

    Triantafyllou, Konstantinos; Lazaridis, Lazaros Dimitrios; Dimitriadis, George D

    2014-01-01

    The use of simulators as educational tools for medical procedures is spreading rapidly and many efforts have been made for their implementation in gastrointestinal endoscopy training. Endoscopy simulation training has been suggested for ascertaining patient safety while positively influencing the trainees’ learning curve. Virtual simulators are the most promising tool among all available types of simulators. These integrated modalities offer a human-like endoscopy experience by combining virtual images of the gastrointestinal tract and haptic realism with using a customized endoscope. From their first steps in the 1980s until today, research involving virtual endoscopic simulators can be divided in two categories: investigation of the impact of virtual simulator training in acquiring endoscopy skills and measuring competence. Emphasis should also be given to the financial impact of their implementation in endoscopy, including the cost of these state-of-the-art simulators and the potential economic benefits from their usage. Advances in technology will contribute to the upgrade of existing models and the development of new ones; while further research should be carried out to discover new fields of application. PMID:24527175

  1. Status of the NASA Balloon Program

    NASA Technical Reports Server (NTRS)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-01-01

    The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.

  2. GHOST balloons around Antarctica

    NASA Technical Reports Server (NTRS)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  3. Concepts for autonomous flight control for a balloon on Mars

    NASA Technical Reports Server (NTRS)

    Heinsheimer, Thomas F.; Friend, Robyn C.; Siegel, Neil G.

    1988-01-01

    Balloons operating as airborne rovers have been suggested as ideal candidates for early exploration of the Martian surface. An international study team composed of scientists from the U.S.S.R., France, and the U.S.A. is planning the launching in 1994 of a balloon system to fly on Mars. The current likely design is a dual thermal/gas balloon that consists of a gas balloon suspended above a solar-heated thermal balloon. At night, the thermal balloon provides no lift, and the balloon system drifts just above the Martian surface; the lift of the gas balloon is just sufficient to prevent the science payload from hitting the ground. During the day, the balloon system flies at an altitude of 4 to 5 kilometers, rising due to the added lift provided by the thermal balloon. Over the course of a single Martian day, there may be winds in several directions, and in fact it can be expected that there will be winds simultaneously in different directions at different altitudes. Therefore, a balloon system capable of controlling its own altitude, via an autonomous flight control system, can take advantage of these different winds to control its direction, thereby greatly increasing both its mission utility and its longevity.

  4. Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons

    PubMed Central

    Antony, Kathleen M.; Racusin, Diana A.; Belfort, Michael A.; Dildy, Gary A.

    2017-01-01

    Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling. PMID:28497006

  5. Effectiveness of a reusable low-cost balloon trocar dissection device in the creation of preperitoneal space during endoscopic surgery. An experimental study in swine.

    PubMed

    Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter

    2015-09-01

    To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.

  6. Autofluorescence imaging endoscopy can distinguish non-erosive reflux disease from functional heartburn: A pilot study

    PubMed Central

    Luo, Xi; Guo, Xiao-Xu; Wang, Wei-Feng; Peng, Li-Hua; Yang, Yun-Sheng; Uedo, Noriya

    2016-01-01

    AIM: To investigate whether autofluorescence imaging (AFI) endoscopy can distinguish non-erosive reflux disease (NERD) from functional heartburn (FH). METHODS: In this prospective observational trial, 127 patients presenting with typical reflux symptoms for > 6 mo were screened. All the participants underwent endoscopy, during which white light imaging (WLI) was followed by AFI. Finally 84 patients with normal esophageal appearance on WLI were enrolled. It was defined as being suggestive of NERD if one or more longitudinal purple lines longer than one centimeter were visualized in the distal part of the esophagus during AFI endoscopy. Ambulatory 24-h multichannel intraluminal impedance and pH monitoring was also performed. After standard proton-pump inhibitor (PPI) tests, subjects were divided into an NERD group and an FH group and the diagnostic performance of AFI endoscopy to differentiate NERD from FH was evaluated. RESULTS: Of 84 endoscopy-negative patients, 36 (42.9%) had a normal pH/impedance test. Of these, 26 patients with favorable responses to PPI tests were classified as having NERD. Finally 10 patients were diagnosed with FH and the others with NERD. Altogether, 68 (81.0%) of the 84 patients were positive on AFI endoscopy. In the NERD group, there were 67 (90.5%) patients with abnormal esophageal findings on AFI endoscopy while only 1 (10%) patient was positive on AFI endoscopy in the FH group. The sensitivity and specificity of AFI in differentiating NERD from FH were 90.5% (95%CI: 81.5%-96.1%) and 90.0% (95%CI: 55.5%-99.7%), respectively. Meanwhile, the accuracy, positive predictive value and negative predictive value of AFI in differentiating between NERD and FH were 90.5% (95%CI: 84.2%-96.8%), 98.5% (95%CI: 92.1%-99.9%) and 56.3% (95%CI: 30.0%-80.2%), respectively. CONCLUSION: Autofluorescence imaging may serve as a complementary method in evaluating patients with NERD and FH. PMID:27076770

  7. Autofluorescence imaging endoscopy can distinguish non-erosive reflux disease from functional heartburn: A pilot study.

    PubMed

    Luo, Xi; Guo, Xiao-Xu; Wang, Wei-Feng; Peng, Li-Hua; Yang, Yun-Sheng; Uedo, Noriya

    2016-04-14

    To investigate whether autofluorescence imaging (AFI) endoscopy can distinguish non-erosive reflux disease (NERD) from functional heartburn (FH). In this prospective observational trial, 127 patients presenting with typical reflux symptoms for > 6 mo were screened. All the participants underwent endoscopy, during which white light imaging (WLI) was followed by AFI. Finally 84 patients with normal esophageal appearance on WLI were enrolled. It was defined as being suggestive of NERD if one or more longitudinal purple lines longer than one centimeter were visualized in the distal part of the esophagus during AFI endoscopy. Ambulatory 24-h multichannel intraluminal impedance and pH monitoring was also performed. After standard proton-pump inhibitor (PPI) tests, subjects were divided into an NERD group and an FH group and the diagnostic performance of AFI endoscopy to differentiate NERD from FH was evaluated. Of 84 endoscopy-negative patients, 36 (42.9%) had a normal pH/impedance test. Of these, 26 patients with favorable responses to PPI tests were classified as having NERD. Finally 10 patients were diagnosed with FH and the others with NERD. Altogether, 68 (81.0%) of the 84 patients were positive on AFI endoscopy. In the NERD group, there were 67 (90.5%) patients with abnormal esophageal findings on AFI endoscopy while only 1 (10%) patient was positive on AFI endoscopy in the FH group. The sensitivity and specificity of AFI in differentiating NERD from FH were 90.5% (95%CI: 81.5%-96.1%) and 90.0% (95%CI: 55.5%-99.7%), respectively. Meanwhile, the accuracy, positive predictive value and negative predictive value of AFI in differentiating between NERD and FH were 90.5% (95%CI: 84.2%-96.8%), 98.5% (95%CI: 92.1%-99.9%) and 56.3% (95%CI: 30.0%-80.2%), respectively. Autofluorescence imaging may serve as a complementary method in evaluating patients with NERD and FH.

  8. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.

    2011-07-15

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less

  9. Paediatric Gastrointestinal Endoscopy: European Society for Paediatric Gastroenterology Hepatology and Nutrition and European Society of Gastrointestinal Endoscopy Guidelines.

    PubMed

    Thomson, Mike; Tringali, Andrea; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf D; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro

    2017-01-01

    This guideline refers to infants, children, and adolescents ages 0 to 18 years. The areas covered include indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; corrosive ingestion and stricture/stenosis endoscopic management; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography; and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease has been dealt with in other guidelines and are therefore not mentioned in this guideline. Training and ongoing skill maintenance are to be dealt with in an imminent sister publication to this.

  10. 14 CFR 101.7 - Hazardous operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...

  11. 14 CFR 101.7 - Hazardous operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...

  12. 14 CFR 101.7 - Hazardous operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...

  13. 14 CFR 101.7 - Hazardous operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...

  14. 14 CFR 101.7 - Hazardous operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AND GENERAL OPERATING RULES MOORED BALLOONS, KITES, AMATEUR ROCKETS AND UNMANNED FREE BALLOONS General § 101.7 Hazardous operations. (a) No person may operate any moored balloon, kite, amateur rocket, or... operating any moored balloon, kite, amateur rocket, or unmanned free balloon may allow an object to be...

  15. Technique and Preliminary Analysis of Drug-Induced Sleep Endoscopy With Online Polygraphic Cardiorespiratory Monitoring in Patients With Obstructive Sleep Apnea Syndrome

    PubMed Central

    Gobbi, Riccardo; Mondini, Susanna; Cerritelli, Luca; Piccin, Ottavio; Scaramuzzino, Giuseppe; Milano, Francesca; Melotti, Maria Rita; Mordini, Francesco; Pirodda, Antonio; Cirignotta, Fabio; Sorrenti, Giovanni

    2017-01-01

    Importance Drug-induced sleep endoscopy is a diagnostic technique that allows dynamic evaluation of the upper airway during artificial sleep. The lack of a standardized procedure and the difficulties associated with direct visual detection of obstructive events result in poor intraobserver and interobserver reliability, especially when otolaryngology surgeons not experienced in the technique are involved. Objectives To describe a drug-induced sleep endoscopy technique implemented with simultaneous polygraphic monitoring of cardiorespiratory parameters (DISE-PG) in patients with a diagnosis of obstructive sleep apnea syndrome and discuss the technique’s possible advantages compared with the standard procedure. Design, Setting, and Participants This prospective cohort study included 50 consecutive patients with obstructive sleep apnea syndrome who underwent DISE-PG from March 1, 2013, to June 30, 2014. A standard protocol was adopted, and all the procedures were carried out in an operation room by an experienced otolaryngology surgeon under the supervision of an anesthesiologist. Endoscopic and polygraphic obstructive respiratory events were analyzed offline in a double-blind setting and randomized order. Main Outcomes and Measures The feasibility and safety of the DISE-PG technique, as well as its sensitivity in detecting respiratory events compared with that of the standard drug-induced sleep endoscopy procedure. Results All 50 patients (43 men and 7 women; mean [SD] age, 51.1 [12.1] years) underwent DISE-PG without technical problems or patient difficulties regarding the procedure. As expected, polygraphic scoring was more sensitive than endoscopic scoring in identifying obstructive events (mean [SD] total events, 13.3 [6.8] vs 5.3 [3.6]; mean [SD] difference, 8.8 [5.6]; 95% CI, 7.3 to 10.4; Cohen d, –1.5). This difference was most pronounced in patients with a higher apnea-hypopnea index (AHI) at baseline (mean [SD] difference for AHI >30, 27.1% [31.0%]; 95% CI, –36.2% to 90.4%; Cohen d, 0.2; for AH I >40, 76.0% [35.5%]; 95% CI, 4.6% to 147.4%; Cohen d, 0.5; for AHI >50, 92.2% [37.2%]; 95% CI, 17.3% to 167.1%; Cohen d, 0.6) and a high percentage of hypopneas (≥75% of all obstructive events) at baseline (mean [SD] difference, 20.2% [5.4%]; 95% CI, 9.2% to 31.3%; Cohen d, 1.1). No other anthropomorphic or polygraphic features at baseline were associated with the differences between the DISE-PG and baseline home sleep apnea test. Conclusions and Relevance The DISE-PG technique is feasible, safe, and more sensitive at detecting an obstructed breathing pattern than is drug-induced sleep endoscopy alone. The DISE-PG technique could be helpful for accurate comprehension of upper airway obstructive dynamics (ie, degree of obstruction and multilevel pattern) and a nonobstructive breathing pattern (ie, central apneas). PMID:28253389

  16. ASGE Bariatric Endoscopy Task Force systematic review and meta-analysis assessing the ASGE PIVI thresholds for adopting endoscopic bariatric therapies.

    PubMed

    Abu Dayyeh, Barham K; Kumar, Nitin; Edmundowicz, Steven A; Jonnalagadda, Sreenivasa; Larsen, Michael; Sullivan, Shelby; Thompson, Christopher C; Banerjee, Subhas

    2015-09-01

    The increasing global burden of obesity and its associated comorbidities has created an urgent need for additional treatment options to fight this pandemic. Endoscopic bariatric therapies (EBTs) provide an effective and minimally invasive treatment approach to obesity that would increase treatment options beyond surgery, medications, and lifestyle measures. This systematic review and meta-analysis were performed by the American Society for Gastrointestinal Endoscopy (ASGE) Bariatric Endoscopy Task Force comprising experts in the subject area and the ASGE Technology Committee Chair to specifically assess whether acceptable performance thresholds outlined by an ASGE Preservation and Incorporation of Valuable endoscopic Innovations (PIVI) document for clinical adoption of available EBTs have been met. After conducting a comprehensive search of several English-language databases, we performed direct meta-analyses by using random-effects models to assess whether the Orbera intragastric balloon (IGB) (Apollo Endosurgery, Austin, Tex) and the EndoBarrier duodenal-jejunal bypass sleeve (DJBS) (GI Dynamics, Lexington, Mass) have met the PIVI thresholds. The meta-analyses results indicate that the Orbera IGB meets the PIVI thresholds for both primary and nonprimary bridge obesity therapy. Based on a meta-analysis of 17 studies including 1683 patients, the percentage of excess weight loss (%EWL) with the Orbera IGB at 12 months was 25.44% (95% confidence interval [CI], 21.47%-29.41%) (random model) with a mean difference in %EWL over controls of 26.9% (95% CI, 15.66%-38.24%; P ≤ .01) in 3 randomized, controlled trials. Furthermore, the pooled percentage of total body weight loss (% TBWL) after Orbera IGB implantation was 12.3% (95% CI, 7.9%–16.73%), 13.16% (95% CI, 12.37%–13.95%), and 11.27% (95% CI, 8.17%–14.36%) at 3, 6, and 12 months after implantation, respectively, thus exceeding the PIVI threshold of 5% TBWL for nonprimary (bridge) obesity therapy. With the data available, the DJBS liner does appear to meet the %EWL PIVI threshold at 12 months, resulting in 35% EWL (95% CI, 24%-46%) but does not meet the 15% EWL over control required by the PIVI. We await review of the pivotal trial data on the efficacy and safety of this device. Data are insufficient to evaluate PIVI thresholds for any other EBT at this time. Both evaluated EBTs had ≤5% incidence of serious adverse events as set by the PIVI document to indicate acceptable safety profiles. Our task force consequently recognizes the Orbera IGB for meeting the PIVI criteria for the management of obesity. As additional data from the other EBTs become available, we will update our recommendations accordingly.

  17. Individual polyp detection rate in routine daily endoscopy practice depends on case-mix.

    PubMed

    Loffeld, R J L F; Liberov, B; Dekkers, P E P

    2015-07-01

    The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. To study the polyp detection rate (PDR) in different endoscopists in the course of years. All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p < 0.001), these two had the longest careers in endoscopy. The two younger endoscopists did significantly less often procedures in patients with anastomoses and because of surveillance (p < 0.001, respectively). One endoscopist detected significantly less colorectal cancers than the other three endoscopists (p < 0.001). This study presents the PDR in normal routine daily endoscopy practice. It can be concluded that the PDR, implicating the ADR, in unselected patients can be lower in individual endoscopists than recommended in the literature. This highly depends on the case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.

  18. Endoscopy and General Surgery - Parts of the Same Activity.

    PubMed

    Doran, Horia; Pătraşcu, Traian

    2016-01-01

    In general and digestive surgical departments, an accurate diagnosis and appropriate treatment of our patients require a wide and continuous access to endoscopy. As many surgical clinics have already developed their own endoscopy units, we plead for the future presence of at least 1 or 2 surgeons, board certified in endoscopy, in every surgical department. We have retrospectively analyzed the activity of the endoscopic unit as a part of the Surgical Clinic of "œDr. I. Cantacuzino" Clinical Hospital since 2007, when it was settled, and its benefits, regarding a higher accessibility for our patients and a reliable support for all the doctors. The number of procedures has increased constantly, from 137, performed by 2 surgeons in 2007 to 1546, in 2015, when 7 surgeons were able to get involved in endoscopic procedures, on a 24/7 schedule. The etiological diagnosis of gastrointestinal hemorrhages, the early detection of gastric, colonic and upper rectal tumors, the follow-up of oncologic patients are only a few of the fields in which endoscopy proved its benefits. Furthermore, surgeons have the practical training and the legal board certification for the approach and treatment of complications. An increased number of surgeons who have also board certification in endoscopy cannot be but very useful. The best way to accomplish this goal would be the inclusion of a digestive endoscopy module during the training program of all future general surgeons. Celsius.

  19. Inversion of solar extinction data from the Apollo-Soyuz Test Project Stratospheric Aerosol Measurement (ASTP/SAM) experiment

    NASA Technical Reports Server (NTRS)

    Pepin, T. J.

    1977-01-01

    The inversion methods are reported that have been used to determine the vertical profile of the extinction coefficient due to the stratospheric aerosols from data measured during the ASTP/SAM solar occultation experiment. Inversion methods include the onion skin peel technique and methods of solving the Fredholm equation for the problem subject to smoothing constraints. The latter of these approaches involves a double inversion scheme. Comparisons are made between the inverted results from the SAM experiment and near simultaneous measurements made by lidar and balloon born dustsonde. The results are used to demonstrate the assumptions required to perform the inversions for aerosols.

  20. A search for solar neutrons from 10-100 MeV

    NASA Technical Reports Server (NTRS)

    Monn, S.; Simnett, G. M.; White, R. S.

    1974-01-01

    A search for solar neutrons is reported from a balloon flight launched from Palestine, Texas on Sept. 26, 1971. The sun was observed from 8:30 to 19:30 CST. The neutrons were detected with a telescope consisting of two 0.5 sq m scintillation detectors spaced 1 meter apart using a double-scattering/time-of-flight technique. Upper limits for solar neutrons in the energy intervals 10 to 30, 30 to 50, and 50 to 100 MeV are .00011, .00026 and .00059 neutron/sq cm-sec, respectively. These are combined into an overall upper limit of .00051 neutron/sq cm-sec.

  1. 14 CFR 31.1 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...

  2. 14 CFR 31.1 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...

  3. 14 CFR 31.1 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... applicable requirements of this part. (c) For purposes of this part— (1) A captive gas balloon is a balloon that derives its lift from a captive lighter-than-air gas; (2) A hot air balloon is a balloon that... STANDARDS: MANNED FREE BALLOONS General § 31.1 Applicability. (a) This part prescribes airworthiness...

  4. Energy from solar balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grena, Roberto

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  5. NASA balloon design and flight - Philosophy and criteria

    NASA Technical Reports Server (NTRS)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  6. New Pulmonary Valvuloplasty Technique by Use of an Hourglass-Shaped Balloon in 3 Adults with Severe Pulmonary Valve Stenosis

    PubMed Central

    Sahin, Tayfun; Karauzum, Kurtulus; Ural, Ertan; Pedersen, Wesley R.

    2018-01-01

    Percutaneous balloon pulmonary valvuloplasty is the preferred therapy for pulmonary valve stenosis. However, the designs of the cylindrical balloons historically used for valvuloplasty have limitations, especially in patients who have large pulmonary annular diameters. The hourglass-shaped V8 Aortic Valvuloplasty Balloon may prove to be an effective alternative. The balloon has 2 large bulbous segments that are separated by a narrowed waist. The geometric shape is maintained throughout inflation, improving fixation and enabling broader leaflet opening. We present our first experience with the V8 balloon in 3 adults who had severe, symptomatic pulmonary valve stenosis. In addition to describing their cases, we detail our sizing technique for pulmonary valvuloplasty with the V8 balloon. Our successful results suggest that the V8 balloon is efficient and safe for balloon pulmonary valvuloplasty in adults with severe pulmonary valve stenosis. PMID:29844739

  7. Percutaneous balloon pulmonary valvuloplasty (PBPV) of extreme pulmonary valve stenosis by the use of Accura balloon.

    PubMed

    Sinha, Santosh Kumar; Mishra, Vikas; Razi, Mahmadula; Jha, Mukesh Jitendra

    2017-10-04

    Transcatheter therapy of valvular pulmonary stenosis is one of first catheter interventions facilitating its application in field of structural heart disease and now treatment of choice for significant pulmonary stenosis. Myriads of balloon catheter have been used for this purpose starting from Diamond (Boston Scientific,Natick, MA USA), Marshal (Medi-Tech,Watertown MAUSA), Innoue balloon, Tyshak I and currently Tyshak II. Diameter and length of balloon depend on size of annulus and age group, respectively. Problem with shorter balloon is difficulty in keeping it across the annulus while inflation as it tends to slip distally whereas with longer balloon, potential of tricuspid leak or conduction block as it may impinge on adjacent structures. Potential advantage of Accura balloon over Tyshak balloon lies in its peculiar shape while inflation and variable diameter, making stepwise dilatation possible. Here, we report a case of successful balloon pulmonary valvuloplasty using Accura balloon (Vascular Concept, UK) with little modification of conventional technique. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Scientific Ballooning in India - Recent Developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  9. Thoracoscopic esophagomyotomy for achalasia: maximum gain, minimal pain.

    PubMed

    Maher, J W

    1997-10-01

    Achalasia can be effectively treated by either hydrostatic balloon dilatation or transthoracic modified Heller myotomy. The purpose of this study was to determine whether thoracoscopic methods could be used to achieve surgical results equal to the transthoracic approach with less pain. Twenty-one patients (10 men, 11 women; median age 42 years) had the diagnosis of achalasia confirmed by manometry, radiography, and endoscopy. All had dysphagia; five had weight loss. Median duration of symptoms was 12 months (range: 1 to 360 months). Eleven patients had undergone previous unsuccessful hydrostatic dilatation. Mean esophageal diameter was 5.5 +/- 2.2 cm. All patients underwent attempted modified Heller myotomy through a left thoracoscopic approach. Three patients required conversion to thoracotomy. The myotomy was extended < 1 cm past the squamocolumnar junction. There was one intraoperative perforation and no postoperative complications. All patients were begun on a regular diet on the first postoperative morning. Median length of stay was 2 days, Median follow-up was 22 months (range: 1 to 52 months). Sixteen patients (80%) had excellent relief of their dysphagia. Two patients (10%) had good relief, and two patients had only a fair result, although even they claim to be much improved. Thoracoscopic Heller myotomy reproduces the superior results of open esophagomyotomy with a reduced hospitalization and reduced incisional pain and disability.

  10. Injury to endoscopic personnel from tripping over exposed cords, wires, and tubing in the endoscopy suite: a preventable cause of potentially severe workplace injury.

    PubMed

    Cappell, Mitchell S

    2010-04-01

    BACKGROUND The endoscopy unit before remediation may be a high-risk area for slip and fall injuries due to a large number of exposed above-the-floor wires in the endoscopy rooms, dimmed lighting during endoscopic procedures, and staff inattention to obstacles due to preoccupation with the endoscopic patient. AIM To describe a novel, previously unappreciated workplace hazard to endoscopic personnel: Exposed wires in the endoscopy unit.METHODS This study is a retrospective review of 110,000 endoscopic procedures performed during the last 5 years at an academic, teaching hospital with a high-volume endoscopy unit. All significant orthopedic injuries to endoscopic personnel from slips, twists, and falls from tripping over exposed cords in the endoscopy unit were reviewed. The severity of injury was documented based on roentgenographic findings, number of days of missed work, number of days with a modified work schedule, and requirement for orthopedic surgery. The number of potentially exposed cords per endoscopy room was determined. RESULTS During the 5-year study period, three endoscopic personnel suffered significant orthopedic injuries from slips, twists, and falls from tripping over cords, wires, or tubing lying exposed over the floor in the endoscopy suite: The resulting injuries consisted of fourth and fifth metacarpal hand fractures due to a fall after tripping on oxygen tubing; a rib fracture due to tripping on electrical wires trailing from an endoscopy cart; and a grade II ankle sprain due to the foot becoming entangled in oxygen tubing. All injuries resulted in lost days of work [mean 9.3 +/- 11.0 (SD) days] and in additional days of restricted work (mean 41.7 +/- 31.8 days). One injury required orthopedic surgery. Hospital review revealed a mean of 35.3 +/- 7.5 cords, wires, or tubing per endoscopy procedure room, the majority of which were exposed above the floor before remediation (n = 10 rooms). Remediation of exposed wires included: bundling related wires together in a cable to reduce the number of independent wires, covering exposed wires on the floor with a nonslip heavy mat, and running wires from ceiling outlets to equipment high above ground (e.g. mounted endoscopy video monitors). CONCLUSIONS Tripping, slipping, and falling over exposed wires can cause significant injury to endoscopic personnel. This previously undescribed hazard should be preventable by simple remediation, and all endoscopic personnel, hospital architects, hospital administrators, and governmental regulators should be alerted to this potential hazard

  11. Endoscopic management and outcomes of pregnant women hospitalized for nonvariceal upper GI bleeding: a nationwide analysis.

    PubMed

    Nguyen, Geoffrey C; Dinani, Amreen M; Pivovarov, Kevin

    2010-11-01

    Upper GI endoscopy has an important diagnostic and therapeutic role in the management of nonvariceal upper GI bleeding (NVUGB). To characterize nationwide patterns of utilization of upper GI endoscopy in pregnant women with NVUGB and to assess health outcomes. Retrospective cohort study. Participating hospitals from the Nationwide Inpatient Sample, 1998-2007. Pregnant and age-matched nonpregnant women admitted for NVUGB. The study population was classified as pregnant women with NVUGB (n = 1210) and nonpregnant women with NVUGB (n = 6050). Rate of upper GI endoscopy, maternal mortality, fetal death/complications, and premature delivery. Pregnant women were less likely than nonpregnant women to undergo upper GI endoscopy (26% vs 69%; P < .0001) even after adjustment for comorbidities, transfusion requirement, and the presence of hypovolemic shock (adjusted odds ratio, 0.19; 95% confidence interval, 0.16-0.22). Among those who underwent endoscopy, pregnant women were less likely to undergo the procedure within 24 hours of admission (50% vs 57%; P = .02). Mortality was lower among pregnant women compared with nonpregnant women (0% vs 0.6%; P = .006). In comparing outcomes between those who did and did not undergo endoscopy, there was no difference in fetal loss (0.2% vs 0.6%), fetal distress/complications (2.7% vs 2.6%), or premature delivery (7.3% vs 6.4%). The study was based on administrative data. A conservative nonendoscopic approach is common in the management of pregnant women with NVUGB and is not associated with worse maternal or fetal outcomes. Upper GI endoscopy is, however, safe when judiciously implemented in the actively bleeding patient. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. European Society of Gastrointestinal Endoscopy - Establishing the key unanswered research questions within gastrointestinal endoscopy.

    PubMed

    Rees, Colin J; Ngu, Wee Sing; Regula, Jaroslaw; Bisschops, Raf; Saftoiu, Adrian; Dekker, Evelien; Gralnek, Ian; Ciocirlan, Mihai; Dinis-Ribeiro, Mario; Jover, Rodrigo; Meisner, Søren; Spada, Cristiano; Hassan, Cesare; Valori, Roland; Hucl, Tomas; Le Moine, Olivier; Domagk, Dirk; Kaminski, Michal F; Bretthauer, Michael; Rutter, Matthew D; Aabakken, Lars; Ponchon, Thierry; Fockens, Paul; Siersema, Peter D

    2016-10-01

    Background and study aim: Gastrointestinal endoscopy is a rapidly evolving research field. The European Society of Gastrointestinal Endoscopy (ESGE) plays a key role in shaping opinion and endoscopy activity throughout Europe and further afield. Establishing key unanswered questions within the field of endoscopy and prioritizing those that are important enables researchers and funders to appropriately allocate resources. Methods: Over 2 years, the ESGE Research Committee gathered information on research priorities and refined them through a modified Delphi approach. Consultations were held with the ESGE Governing Board and Quality Improvement Committee to identify important unanswered questions. Research workshops were held at the 21st United European Gastroenterology Week. Research questions were refined by the ESGE Research Committee and Governing Board, compiled into an online survey, and distributed to all ESGE members, who were invited to rank each question by priority. Results: The final questionnaire yielded 291 responses from over 60 countries. The three countries with the highest response rates were Spain, Italy, and United Kingdom. Most responders were from teaching hospitals (62 %) and were specialist endoscopists (51 %). Responses were analyzed with weighted rankings, resulting in prioritization of 26 key unanswered questions. The top ranked generic questions were: 1) How do we define the correct surveillance interval following endoscopic diagnosis? 2) How do we correctly utilize advanced endoscopic imaging? 3) What are the best markers of endoscopy quality? Conclusion: Following this comprehensive process, the ESGE has identified and ranked the key unanswered questions within the field of gastrointestinal endoscopy. Researchers, funders, and journals should prioritize studies that seek to answer these important questions. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate-the learning curve for endoscopy training

    PubMed Central

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-01-01

    BACKGROUND: Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. OBJECTIVE: To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. METHODS: The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists/surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The ‘Endoscopy Task Load Index’ was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. RESULTS: From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. DISCUSSION: The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers. PMID:24619638

  14. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopera, Jorge E., E-mail: Lopera@uthscsa.ed; Alvarez, Alex; Trimmer, Clayton

    2009-01-15

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm{sup 3}, respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containingmore » a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.« less

  15. Evidence based review of the impact of image enhanced endoscopy in the diagnosis of gastric disorders

    PubMed Central

    Hussain, Ikram; Ang, Tiing Leong

    2016-01-01

    Gastric cancer is the third most common cause of cancer-related death. Advanced stages of gastric cancers generally have grim prognosis. But, good prognosis can be achieved if such cancers are detected, diagnosed and resected at early stages. However, early gastric cancers and its precursors often produce only subtle mucosal changes and therefore quite commonly remain elusive at the conventional examination with white light endoscopy. Image-enhanced endoscopy makes mucosal lesions more conspicuous and can therefore potentially yield earlier and more accurate diagnoses. Recent years have seen growing work of research in support of various types of image enhanced endoscopy (IEE) techniques (e.g., dye-chromoendoscopy; magnification endoscopy; narrow-band imaging; flexible spectral imaging color enhancement; and I-SCAN) for a variety of gastric pathologies. In this review, we will examine the evidence for the utilization of various IEE techniques in the diagnosis of gastric disorders. PMID:28042388

  16. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    PubMed

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  17. Retained intraaortic balloon. Case report and review of the literature.

    PubMed

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  18. Scientific ballooning in India Recent developments

    NASA Astrophysics Data System (ADS)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  19. Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloon.

    PubMed

    Secco, Gioel Gabrio; Ghione, Matteo; Mattesini, Alessio; Dall'Ara, Gianni; Ghilencea, Liviu; Kilickesmez, Kadriye; De Luca, Giuseppe; Fattori, Rossella; Parisi, Rosario; Marino, Paolo Nicola; Lupi, Alessandro; Foin, Nicolas; Di Mario, Carlo

    2016-06-20

    Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.

  20. Pravastatin and endothelium dependent vasomotion after coronary angioplasty: the PREFACE trial

    PubMed Central

    Mulder, H; Schalij, M; Kauer, B; Visser, R; van Dijkman, P R M; Jukema, J; Zwinderman, A; Bruschke, A

    2001-01-01

    OBJECTIVE—To test the hypothesis that the 3-hydroxy-3-methylglutaryl coenzyme-A reductase inhibitor pravastatin ameliorates endothelium mediated responses of dilated coronary segments: the PREFACE (pravastatin related effects following angioplasty on coronary endothelium) trial.
DESIGN—A double blind, randomised, placebo controlled, multicentre study.
SETTING—Four hospitals in the Netherlands.
PATIENTS—63 non-smoking, non-hypercholesterolaemic patients scheduled for elective balloon angioplasty (pravastatin 34, placebo 29).
INTERVENTIONS—The effects of three months of pravastatin treatment (40 mg daily) on endothelium dependent vasomotor function were studied. Balloon angioplasty was undertaken one month after randomisation, and coronary vasomotor function tests using acetylcholine were performed two months after balloon angioplasty. The angiograms were analysed quantitatively.
MAIN OUTCOME MEASURES—The efficacy measure was the acetylcholine induced change in mean arterial diameter, determined in the dilated segment and in an angiographically normal segment of an adjacent non-manipulated coronary artery.
RESULTS—Increasing acetylcholine doses produced vasoconstriction in the dilated segments (p = 0.004) but not in the normal segments. Pravastatin did not affect the vascular response to acetylcholine in either the dilated segments (p = 0.09) or the non-dilated sites. Endothelium dependent vasomotion in normal segments was correlated with that in dilated segments (r = 0.47, p < 0.001). There were fewer procedure related events in the pravastatin group than in the placebo group (p < 0.05).
CONCLUSIONS—Endothelium dependent vasomotion in normal segments is correlated with that in dilated segments. A significant beneficial effect of pravastatin on endothelial function could not be shown, but in the dilated segments there was a trend towards a beneficial treatment effect in the pravastatin group.


Keywords: angioplasty; endothelium; acetylcholine; pravastatin PMID:11602546

  1. Stability analysis and trend study of a balloon tethered in a wind, with experimental comparisons

    NASA Technical Reports Server (NTRS)

    Redd, L. T.; Bland, S. R.; Bennett, R. M.

    1973-01-01

    A stability analysis and trend study for a balloon tethered in a steady wind are presented. The linearized, stability-derivative type analysis includes balloon aerodynamics, buoyancy, mass (including apparent mass), and static forces resulting from the tether cable. The analysis has been applied to a balloon 7.64 m in length, and the results are compared with those from tow tests of this balloon. This comparison shows that the analysis gives reasonable predictions for the damping, frequencies, modes of motion, and stability boundaries exhibited by the balloon. A trend study for the 7.64-m balloon was made to illustrate how the stability boundaries are affected by changes in individual stability parameters. The trends indicated in this study may also be applicable to many other tethered-balloon systems.

  2. A comparative study of internally and externally capped balloons using small scale test balloons

    NASA Technical Reports Server (NTRS)

    Bell, Douglas P.

    1994-01-01

    Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.

  3. Scientific Balloons for Venus Exploration

    NASA Astrophysics Data System (ADS)

    Cutts, James; Yavrouian, Andre; Nott, Julian; Baines, Kevin; Limaye, Sanjay; Wilson, Colin; Kerzhanovich, Viktor; Voss, Paul; Hall, Jeffery

    Almost 30 years ago, two balloons were successfully deployed into the atmosphere of Venus as an element of the VeGa - Venus Halley mission conducted by the Soviet Union. As interest in further Venus exploration grows among the established planetary exploration agencies - in Europe, Japan, Russia and the United States, use of balloons is emerging as an essential part of that investigative program. Venus balloons have been proposed in NASA’s Discovery program and ESA’s cosmic vision program and are a key element in NASA’s strategic plan for Venus exploration. At JPL, the focus for the last decade has been on the development of a 7m diameter superpressure pressure(twice that of VeGa) capable of carrying a 100 kg payload (14 times that of VeGA balloons), operating for more than 30 days (15 times the 2 day flight duration of the VeGa balloons) and transmitting up to 20 Mbit of data (300 times that of VeGa balloons). This new generation of balloons must tolerate day night transitions on Venus as well as extended exposure to the sulfuric acid environment. These constant altitude balloons operating at an altitude of about 55 km on Venus where temperatures are benign can also deploy sondes to sound the atmosphere beneath the probe and deliver deep sondes equipped to survive and operate down to the surface. The technology for these balloons is now maturing rapidly and we are now looking forward to the prospects for altitude control balloons that can cycle repeatedly through the Venus cloud region. One concept, which has been used for tropospheric profiling in Antarctica, is the pumped-helium balloon, with heritage to the anchor balloon, and would be best adapted for flight above the 55 km level. Phase change balloons, which use the atmosphere as a heat engine, can be used to investigate the lower cloud region down to 30 km. Progress in components for high temperature operation may also enable investigation of the deep atmosphere of Venus with metal-based balloons.

  4. Ballooning Then...and Ballooning Now.

    ERIC Educational Resources Information Center

    Journal of Aerospace Education, 1978

    1978-01-01

    Describes the history of hot-air balloon travel, starting with its French origins and continuing through to the 1978 national championship. An address for Balloon Federation of America membership is included. (MA)

  5. Retained intraaortic balloon. Case report and review of the literature.

    PubMed Central

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home. Images PMID:8605436

  6. The French balloon and sounding rocket space program

    NASA Astrophysics Data System (ADS)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  7. Staffing levels in endoscopy units.

    PubMed

    Ott, B J; Igo, M; Shields, N

    1994-04-01

    Staffing the endoscopy area has become increasingly complex. Growth in procedure volumes, changes in technology, and the application of endoscopy in the diagnosis and treatment of disease contribute to the complexities. The manager must deal with these changes, maintain costs, and still provide adequate staffing to ensure patient safety and quality care. The purpose of this article is to present the results of a laboratory manager survey conducted in 1990. Of 51 laboratory managers who responded, those who rated their laboratories to be adequately staffed averaged 4.2 hr per procedure. The survey results may be useful to laboratory managers seeking to calculate staff needs in a typical endoscopy area.

  8. Sedation and Monitoring in the Pediatric Patient during Gastrointestinal Endoscopy.

    PubMed

    Chung, Hyun Kee; Lightdale, Jenifer R

    2016-07-01

    Sedation is a fundamental component of pediatric gastrointestinal procedures. The 2 main types of sedation for pediatric endoscopy remain general anesthesia and procedural sedation. Although anesthesiologist-administered sedation protocols are more common, there is no ideal regimen for endoscopy in children. This article discusses specific levels of sedation for endoscopy as well as various regimens that can be used to achieve each. Risks and considerations that may be specific to performing gastrointestinal procedures in children are reviewed. Finally, potential future directions for sedation and monitoring that may change the practice of pediatric gastroenterology and ultimately patient outcomes are examined. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. System for clinical photometric stereo endoscopy

    NASA Astrophysics Data System (ADS)

    Durr, Nicholas J.; González, Germán.; Lim, Daryl; Traverso, Giovanni; Nishioka, Norman S.; Vakoc, Benjamin J.; Parot, Vicente

    2014-02-01

    Photometric stereo endoscopy is a technique that captures information about the high-spatial-frequency topography of the field of view simultaneously with a conventional color image. Here we describe a system that will enable photometric stereo endoscopy to be clinically evaluated in the large intestine of human patients. The clinical photometric stereo endoscopy system consists of a commercial gastroscope, a commercial video processor, an image capturing and processing unit, custom synchronization electronics, white light LEDs, a set of four fibers with diffusing tips, and an alignment cap. The custom pieces that come into contact with the patient are composed of biocompatible materials that can be sterilized before use. The components can then be assembled in the endoscopy suite before use. The resulting endoscope has the same outer diameter as a conventional colonoscope (14 mm), plugs into a commercial video processor, captures topography and color images at 15 Hz, and displays the conventional color image to the gastroenterologist in real-time. We show that this system can capture a color and topographical video in a tubular colon phantom, demonstrating robustness to complex geometries and motion. The reported system is suitable for in vivo evaluation of photometric stereo endoscopy in the human large intestine.

  10. Gastrointestinal endoscopy in pregnancy

    PubMed Central

    Savas, Nurten

    2014-01-01

    Gastrointestinal endoscopy has a major diagnostic and therapeutic role in most gastrointestinal disorders; however, limited information is available about clinical efficacy and safety in pregnant patients. The major risks of endoscopy during pregnancy include potential harm to the fetus because of hypoxia, premature labor, trauma and teratogenesis. In some cases, endoscopic procedures may be postponed until after delivery. When emergency or urgent indications are present, endoscopic procedures may be considered with some precautions. United States Food and Drug Administration category B drugs may be used in low doses. Endoscopic procedures during pregnancy may include upper gastrointestinal endoscopy, percutaneous endoscopic gastrostomy, sigmoidoscopy, colonoscopy, enteroscopy of the small bowel or video capsule endoscopy, endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography. All gastrointestinal endoscopic procedures in pregnant patients should be performed in hospitals by expert endoscopists and an obstetrician should be informed about all endoscopic procedures. The endoscopy and flexible sigmoidoscopy may be safe for the fetus and pregnant patient, and may be performed during pregnancy when strong indications are present. Colonoscopy for pregnant patients may be considered for strong indications during the second trimester. Although therapeutic endoscopic retrograde cholangiopancreatography may be considered during pregnancy, this procedure should be performed only for strong indications and attempts should be made to minimize radiation exposure. PMID:25386072

  11. Review of musculoskeletal injuries and prevention in the endoscopy practitioner.

    PubMed

    Harvin, Glenn

    2014-08-01

    Practitioners of endoscopy often experience musculoskeletal pain and injury (most often in the back, neck, shoulders, hands, wrists, and thumbs) that are associated with the minute and repetitive strain that is placed on these areas during endoscopic procedures. This review of the current documentation of endoscopy-related pain and injuries among practitioners finds that such problems are widespread and specific in kind as well as strongly correlated with high procedure volume and procedure duration. Research on the nature and impact of cumulative trauma and overuse syndromes in other professions such as dentistry, pianists, production labor, and athletics is brought to bear on the work of the endoscopist. A more thorough understanding of the nature and prevalence of work-related pain and injury sustained by endoscopists should inform further development of ergonomic practices and equipment design. This article reviews current recommendations for ergonomic design in the endoscopy procedure space and finds that reported compliance with those recommendations is quite low. Strategies for the management of the risk of musculoskeletal injuries related to the practice of endoscopy include compliance with currently recommended ergonomic practices, education of trainees in ergonomic technique when practicing endoscopy, and research toward the modification and development of more ergonomic endoscopes and procedure spaces.

  12. Review on sedation for gastrointestinal tract endoscopy in children by non-anesthesiologists

    PubMed Central

    Orel, Rok; Brecelj, Jernej; Dias, Jorge Amil; Romano, Claudio; Barros, Fernanda; Thomson, Mike; Vandenplas, Yvan

    2015-01-01

    AIM: To present evidence and formulate recommendations for sedation in pediatric gastrointestinal (GI) endoscopy by non-anesthesiologists. METHODS: The databases MEDLINE, Cochrane and EMBASE were searched for the following keywords “endoscopy, GI”, “endoscopy, digestive system” AND “sedation”, “conscious sedation”, “moderate sedation”, “deep sedation” and “hypnotics and sedatives” for publications in English restricted to the pediatric age. We searched additional information published between January 2011 and January 2014. Searches for (upper) GI endoscopy sedation in pediatrics and sedation guidelines by non-anesthesiologists for the adult population were performed. RESULTS: From the available studies three sedation protocols are highlighted. Propofol, which seems to offer the best balance between efficacy and safety is rarely used by non-anesthesiologists mainly because of legal restrictions. Ketamine and a combination of a benzodiazepine and an opioid are more frequently used. Data regarding other sedatives, anesthetics and adjuvant medications used for pediatric GI endoscopy are also presented. CONCLUSION: General anesthesia by a multidisciplinary team led by an anesthesiologist is preferred. The creation of sedation teams led by non-anesthesiologists and a careful selection of anesthetic drugs may offer an alternative, but should be in line with national legislation and institutional regulations. PMID:26240691

  13. The Past, Present, and Future of Image-Enhanced Endoscopy

    PubMed Central

    Jang, Jae-Young

    2015-01-01

    Despite the remarkable progress recently made to enhance the resolution of white-light endoscopy, detection, and diagnosis of premalignant lesions, such as adenomas and subtle early-stage cancers, remains a great challenge. As for example, although chromoendoscopy, such as endoscopy using indigo carmine, is useful for the early diagnosis of subtle lesions, the technique presents various disadvantages ranging from the time required for spray application of the dye and suctioning of excess dye to the increased difficulty in identifying lesions in the presence of severe inflammation and obstruction of visual field due to the pooling of solution in depressed-type lesions. To overcome these diagnostic problems associated with chromoendoscopy, research has focused on the development of endoscopes based on new optical technologies. Several types of image-enhanced endoscopy methods have recently been presented. In particular, image-enhanced endoscopy has emerged as a new paradigm for the diagnosis of gastrointestinal disorders. Image-enhanced endoscopes provide high-contrast images of lesions by means of optical or electronic technologies, including the contrast enhancement of the mucosal surface and of blood vessels. Chromoendoscopy, narrow-band imaging, i-SCAN, and flexible spectral imaging color enhancement are representative examples of image-enhanced endoscopy discussed in this paper. PMID:26668791

  14. Provision of gastrointestinal endoscopy and related services for a district general hospital. Working Party of the Clinical Services Committee of the British Society of Gastroenterology.

    PubMed

    1991-01-01

    (1) The number of endoscopic examinations performed is rising. Epidemiological data and the workload of well developed units show that annual requirements per head of population are approaching: Upper gastrointestinal 1 in 100 Flexible sigmoidoscopy 1 in 500 Colonoscopy 1 in 500 ERCP 1 in 2000 (2) Open access endoscopy to general practitioners is desirable and increasingly sought. For a district general hospital serving a population of 250,000, this workload entails about 3500 procedures annually, performed during 10 half day routine sessions plus emergency work. (3) High standards of training and experience are needed by all staff, who must work in purpose built accommodation designed to promote efficient and safe practice. (4) The endoscopy unit should be adjacent to day care facilities and near the x ray department. There should be easy access to wards. (5) An endoscopy unit needs at least two endoscopy rooms; a fully ventilated cleaning/disinfection area; rooms for patient reception, preparation, and recovery; and accommodation for administration, storage, and staff amenities. (6) The service should be consultant based. At least 10 clinical sessions are required, made up of six or more consultant sessions and two to four clinical assistant, hospital practitioner, or staff specialist sessions. Each consultant should be expected to commit at least two sessions weekly to endoscopy. Extra consultant sessions may be needed to provide an efficient service. (7) A specially trained nursing sister (grade G or H) and five other endoscopy nurses are needed to care for the patients; their work may be supplemented by care assistants. (8) A new post of endoscopy department assistant (analogous to an operating department assistant) is proposed to maintain and prepare instruments, and to give technical assistance during procedures. (9) A full time secretary should be employed. Records, appointments, and audit should be computer based. (10) ERCP needs the collaboration of an interventional radiologist working with high quality x ray equipment in a specially prepared radiology screening room. This facility may need to serve more than one hospital. (11) A gastrointestinal measurement laboratory can conveniently be combined with the endoscopy unit. In some hospitals one or more gastrointestinal measurement technicians may staff this laboratory. (12) An endoscopy unit is a service department analogous to a radiology department. It needs an annual budget.

  15. Calculating Payload for a Tethered Balloon System

    Treesearch

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  16. Scientific ballooning. Proceedings. PSB Meeting of the COSPAR Panel on Technical Problems Related to Scientific Ballooning which was held during the Thirtieth COSPAR Scientific Assembly, Hamburg (Germany), 11 - 21 Jul 1994.

    NASA Astrophysics Data System (ADS)

    Riedler, W.; Torkar, K.

    1996-05-01

    This issue is grouped into sections on materials, design, performance and analysis of balloons, reviews of major national and international balloon programmes, novel instrumentation and systems for scientific ballooning, and selected recent scientific observations.

  17. Accurate Determination of the Volume of an Irregular Helium Balloon

    ERIC Educational Resources Information Center

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  18. Computed Tomography Evaluation of Esophagogastric Necrosis After Caustic Ingestion.

    PubMed

    Chirica, Mircea; Resche-Rigon, Matthieu; Zagdanski, Anne Marie; Bruzzi, Matthieu; Bouda, Damien; Roland, Eric; Sabatier, François; Bouhidel, Fatiha; Bonnet, Francine; Munoz-Bongrand, Nicolas; Marc Gornet, Jean; Sarfati, Emile; Cattan, Pierre

    2016-07-01

    Endoscopy is the standard of care for emergency patient evaluation after caustic ingestion. However, the inaccuracy of endoscopy in determining the depth of intramural necrosis may lead to inappropriate decision-making with devastating consequences. Our aim was to evaluate the use of computed tomography (CT) for the emergency diagnostic workup of patients with caustic injuries. In a prospective study, we used a combined endoscopy-CT decision-making algorithm. The primary outcome was pathology-confirmed digestive necrosis. The respective utility of CT and endoscopy in the decision-making process were compared. Transmural endoscopic necrosis was defined as grade 3b injuries; signs of transmural CT necrosis included absence of postcontrast gastric/ esophageal-wall enhancement, esophageal-wall blurring, and periesophageal-fat blurring. We included 120 patients (59 men, median age 44 years). Emergency surgery was performed in 24 patients (20%) and digestive resection was completed in 16. Three patients (3%) died and 28 patients (23%) experienced complications. Pathology revealed transmural necrosis in 9/11 esophagectomy and 16/16 gastrectomy specimens. Severe oropharyngeal injuries (P = 0.015), increased levels of blood lactate (P = 0.007), alanine aminotransferase (P = 0.027), bilirubin (P = 0.005), and low platelet counts (P > 0.0001) were predictive of digestive necrosis. Decision-making relying on CT alone or on a combined CT-endoscopy algorithm was similar and would have spared 19 unnecessary esophagectomies and 16 explorative laparotomies compared with an endoscopy-alone algorithm. Endoscopy did never rectify a wrong CT decision. Emergency decision-making after caustic injuries can rely on CT alone.

  19. Prior esophagogastroduodenoscopy does not affect the cecal intubation time at bidirectional endoscopies

    PubMed Central

    Öner, Osman Zekai; Demirci, Rojbin Karakoyun; Gündüz, Umut Rıza; Aslaner, Arif; Koç, Ümit; Bülbüller, Nurullah

    2013-01-01

    Bidirectional endoscopy (BE) is often used to assess patients for the reason of anemia or to screen asymptomatic population for malignancy. Limited clinical data favors to perform first the upper gastrointestinal system endoscopy, but its effect to the duration of colonoscopy is yet to be determined. The aim of this retrospective study is to evaluate the effect of upper gastrointestinal system endoscopy on the time to achieve cecal intubation during colonoscopy in patients undergoing BE. Patients of four endoscopists at similar experience levels were retrospectively identified and categorized into the upper gastrointestinal system endoscopy before colonoscopy group (group 1) or the colonoscopy only group (group 2). The demographics, clinical data and the time to achieve cecal intubation for each patient were analyzed. The mean time to achieve cecal intubation in the first group that included 319 cases was 8.4 ± 0.93 minutes and the mean time in the second group that included 1672 cases was 8.56 ± 1.16 minutes. There was no statistically significant difference between the groups. There was also no significant difference between the Group 1 and Group 2 when compared according to which of the four endoscopists performed the procedures. Performing the upper gastrointestinal system endoscopy prior to colonoscopy did not affect the time to achieve cecal intubation. Considering that performing the upper gastrointestinal system endoscopy prior to the colonoscopy is more advantageous in terms of patient comfort and analgesic requirement, beginning to BE with it seems more favorable. PMID:23936601

  20. Endoscopic training in gastroenterology fellowship: adherence to core curriculum guidelines.

    PubMed

    Jirapinyo, Pichamol; Imaeda, Avlin B; Thompson, Christopher C

    2015-12-01

    The Gastroenterology Core Curriculum and American Society of Gastrointestinal Endoscopy provide guidelines for endoscopic training. Program adherence to these recommendations is unclear. This study aims to assess endoscopic training experience during fellowship. Questionnaire study. The questionnaire was circulated to US fellowship programs, with the assistance of the American Gastroenterological Association. Graduating third-year fellows. Seventy-three fellows returned the questionnaire. Nearly all fellows met the required numbers for esophagoduodenoscopy (98%) and colonoscopy (100%), with fewer meeting requirements for PEG (73%) and non-variceal hemorrhage (75%). The majority of fellows did not meet minimum numbers for variceal banding (40%), esophageal dilation (43%), capsule endoscopy (42%). Fellows rated training in cognitive aspects of endoscopy as 3.86 [1 (inadequate), 5 (excellent)] and reported greatest emphasis on interpreting endoscopic findings and least on virtual colonography. Quality indicators of endoscopy received little emphasis (rating of 3.04; p = 0.00001), with adenoma detection rate being least emphasized. Fifty-six percent of fellows reported having routine endoscopy conferences. Half of the programs have endoscopic simulators, with 15% of fellows being required to use simulation. Following direct hands-on experience, fellows rated external endoscopy courses (64%) as the next most useful experience. Many fellows do not meet required numbers for several endoscopic procedures, and quality indicators receive little emphasis during training. Most programs do not provide simulation training or hold regular endoscopy conferences. Fellowship programs should perform internal audits and make feasible adjustments. Furthermore, it may be time for professional societies to revisit training guidelines.

  1. The endoscopy Global Rating Scale – Canada: Development and implementation of a quality improvement tool

    PubMed Central

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; van Zanten, Sander Veldhuyzen; Daniels, Sandra; Ghattas, George

    2013-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. OBJECTIVE: To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. METHODS: Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). RESULTS: The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes/no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. CONCLUSION: The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide. PMID:23472242

  2. Display modes for CT colonography. Part II. Blinded comparison of axial CT and virtual endoscopic and panoramic endoscopic volume-rendered studies.

    PubMed

    Beaulieu, C F; Jeffrey, R B; Karadi, C; Paik, D S; Napel, S

    1999-07-01

    To determine the sensitivity of radiologist observers for detecting colonic polyps by using three different data review (display) modes for computed tomographic (CT) colonography, or "virtual colonoscopy." CT colonographic data in a patient with a normal colon were used as base data for insertion of digitally synthesized polyps. Forty such polyps (3.5, 5, 7, and 10 mm in diameter) were randomly inserted in four copies of the base data. Axial CT studies, volume-rendered virtual endoscopic movies, and studies from a three-dimensional mode termed "panoramic endoscopy" were reviewed blindly and independently by two radiologists. Detection improved with increasing polyp size. Trends in sensitivity were dependent on whether all inserted lesions or only visible lesions were considered, because modes differed in how completely the colonic surface was depicted. For both reviewers and all polyps 7 mm or larger, panoramic endoscopy resulted in significantly greater sensitivity (90%) than did virtual endoscopy (68%, P = .014). For visible lesions only, the sensitivities were 85%, 81%, and 60% for one reader and 65%, 62%, and 28% for the other for virtual endoscopy, panoramic endoscopy, and axial CT, respectively. Three-dimensional displays were more sensitive than two-dimensional displays (P < .05). The sensitivity of panoramic endoscopy is higher than that of virtual endoscopy, because the former displays more of the colonic surface. Higher sensitivities for three-dimensional displays may justify the additional computation and review time.

  3. The National Scientific Balloon Facility. [balloon launching capabilities of ground facility

    NASA Technical Reports Server (NTRS)

    Kubara, R. S.

    1974-01-01

    The establishment and operation of the National Scientific Balloon Facility are discussed. The balloon launching capabilities are described. The ground support systems, communication facilities, and meteorological services are analyzed.

  4. Esrange Space Center, a Gate to Space

    NASA Astrophysics Data System (ADS)

    Widell, Ola

    Swedish Space Corporation (SSC) is operating the Esrange Space Center in northern Sweden. Space operations have been performed for more than 40 years. We have a unique combination of maintaining balloon and rocket launch operations, and building payloads, providing space vehicles and service systems. Sub-orbital rocket flights with land recovery and short to long duration balloon flights up to weeks are offered. The geographical location, land recovery area and the long term experience makes Swedish Space Corporation and Esrange to an ideal gate for space activities. Stratospheric balloons are primarily used in supporting atmospheric research, validation of satellites and testing of space systems. Balloon operations have been carried out at Esrange since 1974. A large number of balloon flights are yearly launched in cooperation with CNES, France. Since 2005 NASA/CSBF and Esrange provide long duration balloon flights to North America. Flight durations up to 5 days with giant balloons (1.2 Million cubic metres) carrying heavy payload (up to 2500kg) with astronomical instruments has been performed. Balloons are also used as a crane for lifting space vehicles or parachute systems to be dropped and tested from high altitude. Many scientific groups both in US, Europe and Japan have indicated a great need of long duration balloon flights. Esrange will perform a technical polar circum balloon flight during the summer 2008 testing balloon systems and flight technique. We are also working on a permission giving us the opportunity on a circular stratospheric balloon flight around the North Pole.

  5. Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons

    ERIC Educational Resources Information Center

    Jadrich, James; Bruxvoort, Crystal

    2010-01-01

    Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…

  6. Current trends of balloon laryngoplasty in Thailand.

    PubMed

    Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave

    2017-06-01

    To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.

  7. Japanese Balloon Program

    NASA Astrophysics Data System (ADS)

    Yoshida, Tetsuya; Fuke, Hideyuki; Shoji, Yasuhiro; Iijima, Issei; Izutsu, Naoki; Kato, Yoichi; Matsuzaka, Yukihiko; Mizuta, Eiichi; Sato, Takatoshi; Tamura, Keisuke; Saito, Yoshitaka; Kakehashi, Yuya

    2012-07-01

    Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency conducts domestic balloon campaigns at Taiki Aerospace Research Field (TARF) in Hokkaido since 2008. The ballooning at TARF becomes stable after four year operation. Because the field faces to the Pacific Ocean, heavy balloons and payloads can be launched safely using a very unique sliding launcher. Recoveries at the inshore along the Tokachi coast can be done very quickly and smoothly. Unfortunately, flight opportunities are recently limited due to unfriendly weather condition. Unstable Jet stream also prevents us to have so-called `boomerang flight' to achieve long flight duration more than several hours. Six balloon-borne experiments were carried out in 2010 and 2011. Three of them were demonstrations of challenges of space engineering, two were in-situ atmospheric observation, and one was the technical flight of new high-resolution γ-ray telescope. In addition to these flights, we carried out two launches for next generation balloons: one for Tawara-shaped superpressure balloon and the other for ultra-thin high-altitude balloon. In this paper, recent activities of the Japanese scientific balloon program will be introduced. On-going development of the balloon system will also be presented.

  8. Development of a super-pressure balloon with a diamond-shaped net

    NASA Astrophysics Data System (ADS)

    Saito, Y.; Iijima, I.; Matsuzaka, Y.; Matsushima, K.; Tanaka, S.; Kajiwara, K.; Shimadu, S.

    2014-10-01

    The essential reason of the lobed-pumpkin shaped super-pressure balloon to withstand against the high pressure is that the local curvature of the balloon film is kept small. Recently, it has been found that the small local curvature can also be obtained if the balloon is covered by a diamond-shaped net with a vertically elongated shape. The development of the super-pressure balloon using this method was started from a 3-m balloon with a polyethylene film covered by a net using Kevlar ropes. The ground inflation test showed the expected high burst pressure. Then, a 6-m and a 12-m balloon using a polyethylene film and a net using the Vectran were developed and stable deployment was checked through the ground inflation tests. The flight test of a 3000 m3 balloon was performed in 2013 and shown to resist a pressure of at least 400 Pa. In the future, after testing a new design to relax a possible stress concentration around the polar area, test flights of scaled balloons will be performed gradually enlarging their size. The goal is to launch a 300,000 m3 super-pressure balloon.

  9. Fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children.

    PubMed

    Hu, Hong-Tao; Shin, Ji Hoon; Kim, Jin-Hyoung; Jang, Jong Keon; Park, Jung-Hoon; Kim, Tae-Hyung; Nam, Deok Ho; Song, Ho-Young

    2015-07-01

    We aimed to evaluate the safety and clinical effectiveness of fluoroscopically guided large balloon dilatation for treating congenital esophageal stenosis in children. Our study included seven children (mean age 4.0 years) who underwent a total of ten balloon dilatation sessions. The initial balloon diameters were 10-15 mm. The technical success, clinical success (improved food intake and reduced dysphagia within 1 month following the first balloon dilatation), dysphagia recurrence, and complications were retrospectively evaluated. Technical and clinical success rates were 100 %. During the mean 38-month follow-up period after the first balloon dilatation, 3 (43 %) patients underwent only one additional balloon dilatation 4-5 months after the first balloon dilatation for dysphagia recurrence. Two of them showed improvement without further recurrence, while the remaining one underwent partial esophagectomy. Well-contained transmural esophageal rupture (type 2) occurred in two (29 %, 2/7) patients and during two (20 %, 2/10) balloon dilatation sessions. All ruptures were successfully treated conservatively. Our study showed that fluoroscopically guided large balloon dilatation seems to be a simple and effective primary treatment technique for congenital esophageal stenosis in children. Esophageal ruptures were not uncommon although they were not fatal.

  10. Early usage of Bakri postpartum balloon in the management of postpartum hemorrhage: a large prospective, observational multicenter clinical study in South China.

    PubMed

    Wang, Dongyu; Xu, Shuqia; Qiu, Xiwen; Zhu, Caixia; Li, Zhuyu; Wang, Zilian; Hou, Hongying; Gao, Yu; Wang, Xiaoyi; He, Ping; Qin, Yiwei; Liu, Lihua

    2017-12-18

    To evaluate the success rate and protocol of the Bakri balloon for postpartum hemorrhage (PPH) in the course of a prospective observational multicenter cohort study in South China. At 20 hospitals in South China, women with postpartum bleeding who failed to respond to the first-line conservative management and received the Bakri balloon were recruited for the study. Maternal characteristics, PPH characteristics, PPH management and outcomes in regard to the Bakri balloon use were recorded. A total of 472 women had a Bakri balloon tamponade and 407 (86.23%) women were enrolled (67 after vaginal delivery and 340 either during or after cesarean delivery). The success rate of the Bakri balloon in this study was 91.65% (373/407 women). During vaginal deliveries, the group with a hemorrhage >2000 mL before balloon insertion had significantly more blood loss (551.67±635.17 mL vs. 242.06±313.69 mL, P=0.039) and lower maternal hemoglobin (73±21.77 g/L vs. 92.06±19.60 g/L, P=0.029) after using Bakri balloon than the group with a hemorrhage <1000 mL. Similar data were found during cesarean deliveries. The blood loss before and after balloon insertion were significantly higher in the Bakri balloon failure group (1700±1429.88 mL before and 1209.58±1139.72 mL after using the balloon) than those in the success group [918±493.92 mL before (P=0.002) and 266.57±361.60 mL after using the balloon (P=0.001)]. Rapid diagnosis or prognosis of PPH, in combination with early usage of the Bakri postpartum balloon is more effective for the management of PPH.

  11. Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshimatsu, Rika; Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp; Ishikawa, Masaki

    2016-06-15

    PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumormore » enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.« less

  12. Testing of the Anorectal and Pelvic Floor Area

    MedlinePlus

    ... minutes and is well tolerated by most people. Balloon capacity and compliance A balloon capacity and compliance ... while measurements of volume and pressure are recorded. Balloon evacuation study A balloon evacuation study tests pelvic ...

  13. Therapeutic upper gastrointestinal tract endoscopy in Paediatric Gastroenterology

    PubMed Central

    Rahman, Imdadur; Patel, Praful; Boger, Philip; Rasheed, Shahnawaz; Thomson, Mike; Afzal, Nadeem Ahmad

    2015-01-01

    Since the first report of use of endoscopy in children in the 1970s, there has seen an exponential growth in published experience and innovation in the field. In this review article we focus on modern age therapeutic endoscopy practice, explaining use of traditional as well as new and innovative techniques, for diagnosis and treatment of diseases in the paediatric upper gastrointestinal tract. PMID:25789087

  14. Serology for Helicobacter pylori compared with symptom questionnaires in screening before direct access endoscopy.

    PubMed

    Mendall, M A; Jazrawi, R P; Marrero, J M; Molineaux, N; Levi, J; Maxwell, J D; Northfield, T C

    1995-03-01

    This prospective study aimed to compare serology for Helicobacter pylori with two, symptom questionnaires in screening patients before direct access endoscopy. Methods were compared in terms of the number of endoscopies saved and pathology missed in 315 patients referred to a gastroenterology unit by 65 local GPs. The serology used was based on an acid glycine extract of H pylori. One in-house questionnaire was based on the Glasgow dyspepsia (GLADYS) system and the other questionnaire was that reported by Holdstock et al. A cut off point of 6.3 U/ml for H pylori serology was selected for screening patients (97% sensitive and 75% specific). Serology was combined with a history of NSAID usage in determining who should have endoscopy. For the in-house questionnaire, a cut off score of more than 8 out of a possible maximum of 18 was chosen, after prior evaluation in 118 patients referred for direct access endoscopy (the sensitivity for detection of peptic ulcer was 88%, specificity 61%). A cut off score of more than 412 was used for the Holdstock questionnaire. In patients under 45 years, serology detected more peptic ulcers than the in-house questionnaire and the Holdstock questionnaire (27/28 v 24/28, NS and v 20/28, p < 0.05 respectively). The Holdstock questionnaire saved significantly more endoscopies than the other two methods (76/149 v 57/149 for the in-house questionnaire, p = 0.05 and 59/149 for serology, p = 0.05). In all age groups combined, serology was significantly better than the in-house and Holdstock questionnaires at detecting peptic ulcers and gastric cancer (61/63, 52/63, p<0.02, and 50/63, p<0.01 respectively). But serology saved significantly fewer endoscopies (89/315, 135/315, p<0.005, and 119/315, p<0.05 respectively). Serology was inferior to the Holdstock questionnaire at detecting severe oesophagitis. It is concluded that serology is the method of choice in screening before direct access upper gastrointestinal endoscopy in those under 45 years. It best combines a high sensitivity for peptic ulcer disease with a large reduction in unnecessary negative endoscopies.

  15. Endoscopy of the upper gastrointestinal tract as a diagnostic tool for children with human immunodeficiency virus infection.

    PubMed

    Miller, T L; McQuinn, L B; Orav, E J

    1997-05-01

    The purpose of this study was to determine the prevalence of upper gastrointestinal tract lesions in children with human immunodeficiency virus (HIV) infection who undergo endoscopy of the upper gastrointestinal tract and to identify important clinical predictors of abnormal endoscopic results. All HIV-infected children who underwent endoscopy and were followed at Children's Hospital, Boston, from January 1985 to August 1994 were studied. The main outcome measure was endoscopic results, which were categorized into observational, histologic, and microbiologic findings. Potential predictors included height, weight, nutritional interventions, HIV disease stage, CD4 T-lymphocyte count, medications, active infections, and indications for endoscopy. Forty-three endoscopies in unique patients are reported. Most children had advanced HIV infection (67% acquired immunodeficiency syndrome, mean CD4 T-lymphocyte count z score = -2.71, weight z score = -2.04). An abnormal endoscopic finding was discovered in 93% of children and confirmed by histologic, microbiologic, or a combination of these studies in 72% of children. Thirty-five percent of children had an opportunistic pathogen identified endoscopically; 65% of these pathogens were previously undiagnosed. Observational findings often were poor indicators of histologic and microbiologic abnormalities. Independent predictors of abnormal histologic findings include younger age at endoscopy (odds ratio (OR) = 1.16 per year, 95% confidence interval (CI) (1.02, 1.33)) and guaiac-negative stools (OR = 16.7, 95% CI (1.92, 142.9)). Independent predictors of finding a pathogen at the time of endoscopy include a greater number of indications for endoscopy (OR = 2.6 per indication, 95% CI (1.3, 5.3)) and diagnosis of acquired immunodeficiency syndrome (OR = 16.4, 95% CI (1.3, 213)). No other gastrointestinal, nutritional, or immunologic parameters were significantly predictive of endoscopic outcomes. Medical management was changed in 70% of children because of the endoscopic findings. Endoscopy is a useful tool to direct therapy against peptic and infectious disorders of the upper gastrointestinal tract in children with HIV infection. Specific gastrointestinal symptoms are not useful predictors of abnormal results.

  16. On the response of superpressure balloons to displacements from equilibrium density level

    NASA Technical Reports Server (NTRS)

    Levanon, N.; Kushnir, Y.

    1976-01-01

    The response of a superpressure balloon to an initial displacement from its constant-density floating level is examined. An approximate solution is obtained to the governing vertical equation of motion for constant-density superpressure balloons. This solution is used to filter out neutrally buoyant oscillations in balloon records despite the nonlinear behavior of the balloon. The graph depicting the pressure data after deconvolution between the raw pressure data and the normalized balloon wavelet shows clearly the strong filtering-out of the neutral buoyancy oscillations.

  17. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    NASA Astrophysics Data System (ADS)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  18. A buoyant tornado-probe concept incorporating an inverted lifting device. [and balloon combination

    NASA Technical Reports Server (NTRS)

    Grant, F. C.

    1973-01-01

    Addition of an inverted lifting device to a simple balloon probe is shown to make possible low-altitude entry to tornado cores with easier launch conditions than for the simple balloon probe. Balloon-lifter combinations are particularly suitable for penetration of tornadoes with average to strong circulation, but tornadoes of less than average circulation which are inaccessible to simple balloon probes become accessible. The increased launch radius which is needed for access to tornadoes over a wide range of circulation results in entry times of about 3 minutes. For a simple balloon probe the uninflated balloon must be first dropped on, or near, the track of the tornado from a safe distance. The increase in typical launch radius from about 0.75 kilometer to slightly over 1.0 kilometer with a balloon-lifter combination suggests that a direct air launch may be feasible.

  19. Measurement of polar stratospheric NO2 from the 23rd and 24th Japanese Antarctic Research Expedition (JARE) balloon experiments

    NASA Technical Reports Server (NTRS)

    Shibasaki, K.; Iwagami, N.; Ogawa, T.

    1985-01-01

    As a part of the Japanese activities of MAP in the Antarctica, balloon-borne measurements of the stratospheric NO2 profile were planned and carried out by the JARE 23rd and 24th wintering parties. Few results have been reported so far as the stratospheric NO2 profile at high latitude. There were no reported balloon measurements carried out in the Southern Hemisphere. Profiles are presented for the first balloon-borne measurement of the stratospheric NO2 in the Antarctica. Three balloons named JA21, JA25 and JA26 were launched from Syowa Station (69 deg S, 35.6 deg E) using 5000 cu. cm plastic balloons. JA21 balloon was launched on November 24, 1982, and JA25 and JA26 balloons on November 12 and 20, 1983, respectively.

  20. European Venus Explorer: An in-situ mission to Venus using a balloon platform

    NASA Astrophysics Data System (ADS)

    Chassefière, E.; Korablev, O.; Imamura, T.; Baines, K. H.; Wilson, C. F.; Titov, D. V.; Aplin, K. L.; Balint, T.; Blamont, J. E.; Cochrane, C. G.; Ferencz, Cs.; Ferri, F.; Gerasimov, M.; Leitner, J. J.; Lopez-Moreno, J.; Marty, B.; Martynov, M.; Pogrebenko, S. V.; Rodin, A.; Whiteway, J. A.; Zasova, L. V.; the EVE Team

    2009-07-01

    Planetary balloons have a long history already. A small super-pressure balloon was flown in the atmosphere of Venus in the eighties by the Russian-French VEGA mission. For this mission, CNES developed and fully tested a 9 m diameter super-pressure balloon, but finally replaced it by a smaller one due to mass constraints (when it was decided to send Vega to Halley's Comet). Furthermore, several kinds of balloons have been proposed for planetary exploration [Blamont, J., in: Maran, S.P. (Ed.), The Astronomy and Astrophysics Encyclopedia. Cambridge University Press, p. 494, 1991]. A Mars balloon has been studied for the Mars-94 Russian-French mission, which was finally cancelled. Mars and Venus balloons have also been studied and ground tested at JPL, and a low atmosphere Venus balloon is presently under development at JAXA (the Japanese Space Agency). Balloons have been identified as a key element in an ongoing Flagship class mission study at NASA, with an assumed launch date between 2020 and 2025. Recently, it was proposed by a group of scientists, under European leadership, to use a balloon to characterize - by in-situ measurements - the evolution, composition and dynamics of the Venus atmosphere. This balloon is part of a mission called EVE (European Venus Explorer), which has been proposed in response to the ESA AO for the first slice of the Cosmic Vision program by a wide international consortium including Europe, Russia, Japan and USA. The EVE architecture consists of one balloon platform floating at an altitude of 50-60 km, one short lived probe provided by Russia, and an orbiter with a polar orbit to relay data from the balloon and probe, and to perform remote sensing science observations. The balloon type preferred for scientific goals is one, which would oscillate in altitude through the cloud deck. To achieve this flight profile, the balloon envelope would contain a phase change fluid. While this proposal was not selected for the first slice of Cosmic Vision missions, it was ranked first among the remaining concepts within the field of solar system science.

  1. Endovascular balloon-assisted embolization of intracranial and cervical arteriovenous malformations using dual-lumen coaxial balloon microcatheters and Onyx: initial experience.

    PubMed

    Jagadeesan, Bharathi D; Grigoryan, Mikayel; Hassan, Ameer E; Grande, Andrew W; Tummala, Ramachandra P

    2013-12-01

    Ethylene vinyl alcohol copolymer (Onyx) is widely used for the embolization of arteriovenous malformations (AVMs) of the brain, head, and neck. Balloon-assisted Onyx embolization may provide additional unique advantages in the treatment of AVMs in comparison with traditional catheter-based techniques. To report our initial experience in performing balloon-assisted AVM embolization for brain and neck AVMs with the use of the new Scepter-C and Scepter-XC coaxial dual-lumen balloon microcatheters. Balloon-assisted transarterial embolization was performed in a series of 7 patients with AVMs (4 with brain AVMs, 1 with a dural arteriovenous fistula, and 2 with neck AVMs) by using Onyx delivered through the lumen of Scepter-C or Scepter XC coaxial balloon microcatheters. Following the initial balloon-catheter navigation into a feeding artery and the subsequent inflation of the balloon, the embolization was performed by using Onyx 18, Onyx 34, or both. A total of 12 embolization sessions were performed via 17 arterial feeders in these 7 patients. In 1 patient, there was an arterial perforation from the inflation of the balloon; in all others, the embolization goals were successfully achieved with no adverse events. The balloon microcatheters showed excellent navigability, and there were no problems with retrieval or with the repeated inflation and deflation of the balloons. A proximal Onyx plug, which is crucial in many AVM embolizations, was not necessary with this technique. Additionally, fluoroscopy and procedural times seemed lower with this technique compared with conventional embolization methods.

  2. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    PubMed

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  3. Thermal performance modeling of NASA s scientific balloons

    NASA Astrophysics Data System (ADS)

    Franco, H.; Cathey, H.

    The flight performance of a scientific balloon is highly dependant on the interaction between the balloon and its environment. The balloon is a thermal vehicle. Modeling a scientific balloon's thermal performance has proven to be a difficult analytical task. Most previous thermal models have attempted these analyses by using either a bulk thermal model approach, or by simplified representations of the balloon. These approaches to date have provided reasonable, but not very accurate results. Improvements have been made in recent years using thermal analysis tools developed for the thermal modeling of spacecraft and other sophisticated heat transfer problems. These tools, which now allow for accurate modeling of highly transmissive materials, have been applied to the thermal analysis of NASA's scientific balloons. A research effort has been started that utilizes the "Thermal Desktop" addition to AUTO CAD. This paper will discuss the development of thermal models for both conventional and Ultra Long Duration super-pressure balloons. This research effort has focused on incremental analysis stages of development to assess the accuracy of the tool and the required model resolution to produce usable data. The first stage balloon thermal analyses started with simple spherical balloon models with a limited number of nodes, and expanded the number of nodes to determine required model resolution. These models were then modified to include additional details such as load tapes. The second stage analyses looked at natural shaped Zero Pressure balloons. Load tapes were then added to these shapes, again with the goal of determining the required modeling accuracy by varying the number of gores. The third stage, following the same steps as the Zero Pressure balloon efforts, was directed at modeling super-pressure pumpkin shaped balloons. The results were then used to develop analysis guidelines and an approach for modeling balloons for both simple first order estimates and detailed full models. The development of the radiative environment and program input files, the development of the modeling techniques for balloons, and the development of appropriate data output handling techniques for both the raw data and data plots will be discussed. A general guideline to match predicted balloon performance with known flight data will also be presented. One long-term goal of this effort is to develop simplified approaches and techniques to include results in performance codes being developed.

  4. Solar energy collector including a weightless balloon with sun tracking means

    DOEpatents

    Hall, Frederick F.

    1978-01-01

    A solar energy collector having a weightless balloon, the balloon including a transparent polyvinylfluoride hemisphere reinforced with a mesh of ropes secured to its outside surface, and a laminated reflector hemisphere, the inner layer being clear and aluminized on its outside surface and the outer layer being opaque, the balloon being inflated with lighter-than-air gas. A heat collection probe extends into the balloon along the focus of reflection of the reflective hemisphere for conducting coolant into and out of the balloon. The probe is mounted on apparatus for keeping the probe aligned with the sun's path, the apparatus being founded in the earth for withstanding wind pressure on the balloon. The balloon is lashed to the probe by ropes adhered to the outer surface of the balloon for withstanding wind pressures of 100 miles per hour. Preferably, the coolant is liquid sodium-potassium eutectic alloy which will not normally freeze at night in the temperate zones, and when heated to 4,000.degree. R exerts a pressure of only a few atmospheres.

  5. Review of Musculoskeletal Injuries and Prevention in the Endoscopy Practitioner

    PubMed Central

    2014-01-01

    Practitioners of endoscopy often experience musculoskeletal pain and injury (most often in the back, neck, shoulders, hands, wrists, and thumbs) that are associated with the minute and repetitive strain that is placed on these areas during endoscopic procedures. This review of the current documentation of endoscopy-related pain and injuries among practitioners finds that such problems are widespread and specific in kind as well as strongly correlated with high procedure volume and procedure duration. Research on the nature and impact of cumulative trauma and overuse syndromes in other professions such as dentistry, pianists, production labor, and athletics is brought to bear on the work of the endoscopist. A more thorough understanding of the nature and prevalence of work-related pain and injury sustained by endoscopists should inform further development of ergonomic practices and equipment design. This article reviews current recommendations for ergonomic design in the endoscopy procedure space and finds that reported compliance with those recommendations is quite low. Strategies for the management of the risk of musculoskeletal injuries related to the practice of endoscopy include compliance with currently recommended ergonomic practices, education of trainees in ergonomic technique when practicing endoscopy, and research toward the modification and development of more ergonomic endoscopes and procedure spaces. PMID:24798940

  6. African American ethnicity is not associated with development of Barrett's oesophagus after erosive oesophagitis.

    PubMed

    Alkaddour, Ahmad; McGaw, Camille; Hritani, Rama; Palacio, Carlos; Nakshabendi, Rahman; Munoz, Juan Carlos; Vega, Kenneth J

    2015-10-01

    Barrett's oesophagus is the primary risk factor for oesophageal adenocarcinoma; erosive oesophagitis is considered an intermediate step with Barrett's oesophagus development potential upon healing. Barrett's oesophagus occurs in 9-19% following erosive oesophagitis but minimal data exists in African Americans. The study aim was to determine if ethnicity is associated with Barrett's oesophagus formation following erosive oesophagitis. Retrospective review of endoscopies from September 2007 to December 2012 was performed. Inclusion criteria were erosive oesophagitis on index endoscopy, repeat endoscopy ≥6 weeks later and non-Hispanic white or African American ethnicity. Barrett's oesophagus frequency following erosive oesophagitis by ethnicity was compared. A total of 14,303 patients underwent endoscopy during the study period; 1636 had erosive oesophagitis. Repeat endoscopy was performed on 125 non-Hispanic white or African American patients ≥6 weeks from the index procedure. Barrett's oesophagus occurred in 8% of non-Hispanic whites while no African American developed it on repeat endoscopy following erosive oesophagitis (p=0.029). No significant difference was seen between ethnic groups in any clinical parameter assessed. African American ethnicity appears to result in decreased Barrett's oesophagus formation following erosive oesophagitis. Further investigation to demonstrate factors resulting in decreased Barrett's oesophagus formation among African Americans should be performed. Copyright © 2015. Published by Elsevier Ltd.

  7. Ballooning Comes of Age: Make Your Own Balloon.

    ERIC Educational Resources Information Center

    Eckford, Jim

    1983-01-01

    Provides instructions for building a working model of a hot-air balloon, offering suggestions for a successful flight. Indicates that children can be involved in the projects, for example, by filling in colors in the panels of a balloon drawing. (JN)

  8. Flow Past a Descending Balloon

    NASA Technical Reports Server (NTRS)

    Baginski, Frank

    2001-01-01

    In this report, we present our findings related to aerodynamic loading of partially inflated balloon shapes. This report will consider aerodynamic loading of partially inflated inextensible natural shape balloons and some relevant problems in potential flow. For the axisymmetric modeling, we modified our Balloon Design Shape Program (BDSP) to handle axisymmetric inextensible ascent shapes with aerodynamic loading. For a few simple examples of two dimensional potential flows, we used the Matlab PDE Toolbox. In addition, we propose a model for aerodynamic loading of strained energy minimizing balloon shapes with lobes. Numerical solutions are presented for partially inflated strained balloon shapes with lobes and no aerodynamic loading.

  9. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    PubMed

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  10. Two-Dimensional High Definition Versus Three-Dimensional Endoscopy in Endonasal Skull Base Surgery: A Comparative Preclinical Study.

    PubMed

    Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero

    2017-09-01

    Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Correlates of Community-Based Colorectal Cancer Screening in a Rural Population: The Role of Fatalism.

    PubMed

    Crosby, Richard A; Collins, Tom

    2017-09-01

    One largely unexplored barrier to colorectal cancer (CRC) screening is fatalistic beliefs about cancer. The purpose of this study was to identify correlates of ever having endoscopy screenings for CRC and to determine whether fatalism plays a unique role. Because evidence suggests that cancer-associated fatalistic beliefs may be particularly common among rural Americans, the study was conducted in a medically underserved area of rural Appalachia.  METHODS: Rural residents (N = 260) between 51 and 75 years of age, from a medically underserved area of Appalachia, Kentucky, were recruited for a cross-sectional study. The outcome measure was assessed by a single item asking whether participants ever had a colonoscopy or flexible sigmoidoscopy. Demographic and health-related correlates of this outcome were selected based on past studies of rural populations. A single item assessed perceptions of fatalism regarding CRC. Age-adjusted analyses of correlates testing significant at the bivariate level were conducted.  RESULTS: The analytic sample was limited to 135 rural residents indicating they had ever had CRC endoscopy and 107 indicating never having endoscopy. In age-adjusted analyses, only the measure of fatalism had a significant association with having endoscopy. Those endorsing the statement pertaining to fatalism were 2.3 times more likely (95% CI = 1.24-4.27, P = .008) than the remainder to indicate never having endoscopy.  CONCLUSIONS: A community-based approach to the promotion of endoscopy for CRC screening could focus on overcoming CRC-associated fatalism, thereby potentially bringing more unscreened people to endoscopy clinics. © 2017 National Rural Health Association.

  12. Improving the timeliness of procedures in a pediatric endoscopy suite.

    PubMed

    Tomer, Gitit; Choi, Steven; Montalvo, Andrea; Sutton, Sheila; Thompson, John; Rivas, Yolanda

    2014-02-01

    Pediatric endoscopic procedures are essential in the evaluation and treatment of gastrointestinal diseases in children. Although pediatric endoscopists are greatly interested in increasing efficiency and through-put in pediatric endoscopy units, there is scarcely any literature on this critical process. The goal of this study was to improve the timeliness of pediatric endoscopy procedures at Children's Hospital at Montefiore. In June 2010, a pediatric endoscopy quality improvement initiative was formed at Children's Hospital at Montefiore. We identified patient-, equipment-, and physician-related causes for case delays. Pareto charts, cause and effect diagrams, process flow mapping, and statistical process control charts were used for analysis. From June 2010 to December 2012, we were able to significantly decrease the first case endoscopy delay from an average of 17 to 10 minutes (P < .001), second case delay from 39 to 25 minutes (P = .01), third case delay from 61 to 45 minutes (P = .05), and fourth case delay from 79 to 51 minutes (P = .05). Total delay time decreased from 196 to 131 minutes, resulting in a reduction of 65 minutes (P = .02). From June 2010 to August 2011 (preintervention period), an average of 36% of first endoscopy cases started within 5 minutes, 51% within 10 minutes, and 61% within 15 minutes of the scheduled time. From September 2011 to December 2012 (postintervention period), the percentage of cases starting within 5 minutes, 10 minutes, and 15 minutes increased to 47% (P = .07), 61% (P = .04), and 79% (P = .01), respectively. Applying quality improvement methods and tools helped improve pediatric endoscopy timeliness and significantly decreased total delays.

  13. A cost-effectiveness analysis of diagnostic strategies for symptomatic patients with ileal pouch-anal anastomosis.

    PubMed

    Shen, Bo; Shermock, Kenneth M; Fazio, Victor W; Achkar, Jean-Paul; Brzezinski, Aaron; Bevins, Charles L; Bambrick, Marlene L; Remzi, Feza H; Lashner, Bret A

    2003-11-01

    Pouchitis is often diagnosed based on symptoms and empirically treated with antibiotics (treat-first strategy). However, symptom assessment alone is not reliable for diagnosis, and an initial evaluation with pouch endoscopy (test-first strategy) has been shown to be more accurate. Cost-effectiveness of these strategies has not been compared. The aim of this study was to compare cost-effectiveness of different clinical approaches for patients with symptoms suggestive of pouchitis. Pouchitis was defined as pouchitis disease activity index scores > or =7. The frequency of pouchitis in symptomatic patients with ileal pouch was estimated to be 51%; the efficacy for initial therapy with metronidazole (MTZ) and ciprofloxacin (CIP) was 75% and 85%, respectively. Cost estimates were obtained from Medicare reimbursement data. Six competing strategies (MTZ trial, CIP trial, MTZ-then-CIP trial, CIP-then-MTZ trial, pouch endoscopy with biopsy, and pouch endoscopy without biopsy) were modeled in a decision tree. Costs per correct diagnosis with appropriate treatment were $194 for MTZ trial, $279 for CIP trial, $208 for MTZ-then-CIP trial, $261 for CIP-then-MTZ trial, $352 for pouch endoscopy with biopsy, and $243 for pouch endoscopy without biopsy. Of the two strategies with the lowest cost, the pouch endoscopy without biopsy strategy costs $50 more per patient than the MTZ trial strategy but results in an additional 15 days for early diagnosis and thus initiation of appropriate treatment (incremental cost-effectiveness ratio $3 per additional day gained). The results of base-case analysis were robust in sensitivity analyses. Although the MTZ-trial strategy had the lowest cost, the pouch endoscopy without biopsy strategy was most cost-effective. Therefore, based on its relatively low cost and the avoidance of both diagnostic delay and adverse effects associated with unnecessary antibiotics, pouch endoscopy without biopsy is the recommended strategy among those tested for the diagnosis of pouchitis.

  14. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy.

    PubMed

    Vargo, John J; Zuccaro, Gregory; Dumot, John A; Conwell, Darwin L; Morrow, J Brad; Shay, Steven S

    2002-06-01

    Recommendations from the American Society of Anesthesiologists suggest that monitoring for apnea using the detection of exhaled carbon dioxide (capnography) is a useful adjunct in the assessment of ventilatory status of patients undergoing sedation and analgesia. There are no data on the utility of capnography in GI endoscopy, nor is the frequency of abnormal ventilatory activity during endoscopy known. The aims of this study were to determine the following: (1) the frequency of abnormal ventilatory activity during therapeutic upper endoscopy, (2) the sensitivity of observation and pulse oximetry in the detection of apnea or disordered respiration, and (3) whether capnography provides an improvement over accepted monitoring techniques. Forty-nine patients undergoing therapeutic upper endoscopy were monitored with standard methods including pulse oximetry, automated blood pressure measurement, and visual assessment. In addition, graphic assessment of respiratory activity with sidestream capnography was performed in all patients. Endoscopy personnel were blinded to capnography data. Episodes of apnea or disordered respiration detected by capnography were documented and compared with the occurrence of hypoxemia, hypercapnea, hypotension, and the recognition of abnormal respiratory activity by endoscopy personnel. Comparison of simultaneous respiratory rate measurements obtained by capnography and by auscultation with a pretracheal stethoscope verified that capnography was an excellent indicator of respiratory rate when compared with the reference standard (auscultation) (r = 0.967, p < 0.001). Fifty-four episodes of apnea or disordered respiration occurred in 28 patients (mean duration 70.8 seconds). Only 50% of apnea or disordered respiration episodes were eventually detected by pulse oximetry. None were detected by visual assessment (p < 0.0010). Apnea/disordered respiration occurs commonly during therapeutic upper endoscopy and frequently precedes the development of hypoxemia. Potentially important abnormalities in respiratory activity are undetected with pulse oximetry and visual assessment.

  15. Knowledge of quality performance measures associated with endoscopy among gastroenterology trainees and the impact of a web-based intervention.

    PubMed

    Thompson, Jennifer S; Lebwohl, Benjamin; Syngal, Sapna; Kastrinos, Fay

    2012-07-01

    Knowledge of quality measures in endoscopy among trainees is unknown. To assess knowledge of endoscopy-related quality indicators among U.S. trainees and determine whether it improves with a Web-based intervention. Randomized, controlled study. Multicenter. This study involved trainees identified from the American Society for Gastrointestinal Endoscopy membership database. Participants were invited to complete an 18-question online test. Respondents were randomized to receive a Web-based tutorial (intervention) or not. The test was readministered 6 weeks after randomization to determine the intervention's impact. Baseline knowledge of endoscopy-related quality indicators and impact of the tutorial. A total of 347 of 1220 trainees (28%) completed the test; the mean percentage of correct responses was 55%. For screening colonoscopy, 44% knew the adenoma detection rate benchmark, 42% identified the cecal intubation rate goal, and 74% knew the recommended minimum withdrawal time. A total of 208 of 347 trainees (59%) completed the second test; baseline scores were similar for the tutorial (n = 106) and no tutorial (n = 102) groups (56.4% vs 56.9%, respectively). Scores improved after intervention for the tutorial group (65%, P = .003) but remained unchanged in the no tutorial group. On multivariate analysis, each additional year in training (odds ratio [OR] 2.3; 95% confidence interval [CI], 1.5-3.4), training at an academic institution (OR 2.6; 95% CI, 1.1-6.3), and receiving the tutorial (OR 3.2; 95% CI, 1.7-5.9) were associated with scores in the upper tertile. Low response rate. Knowledge of endoscopy-related quality performance measures is low among trainees but can improve with a Web-based tutorial. Gastroenterology training programs may need to incorporate a formal didactic curriculum to supplement practice-based learning of quality standards in endoscopy. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. Indicators of safety compromise in gastrointestinal endoscopy.

    PubMed

    Borgaonkar, Mark Ram; Hookey, Lawrence; Hollingworth, Roger; Kuipers, Ernst J; Forster, Alan; Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dube, Catherine; Enns, Robert; Macintosh, Donald; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Valori, Roland

    2012-02-01

    The importance of quality indicators has become increasingly recognized in gastrointestinal endoscopy. Patient safety requires the identification and monitoring of occurrences associated with harm or the potential for harm. The identification of relevant indicators of safety compromise is, therefore, a critical element that is key to the effective implementation of endoscopy quality improvement programs. To identify key indicators of safety compromise in gastrointestinal endoscopy. The Canadian Association of Gastroenterology Safety and Quality Indicators in Endoscopy Consensus Group was formed to address issues of quality in endoscopy. A subcommittee was formed to identify key safety indicators. A systematic literature review was undertaken, and articles pertinent to safety in endoscopy were identified and reviewed. All complications and measures used to document safety were recorded. From this, a preliminary list of 16 indicators was compiled and presented to the 35-person consensus group during a three-day meeting. A revised list of 20 items was subsequently put to the consensus group for vote for inclusion on the final list of safety indicators. Items were retained only if the consensus group highly agreed on their importance. A total of 19 indicators of safety compromise were retained and grouped into the three following categories: medication-related - the need for CPR, use of reversal agents, hypoxia, hypotension, hypertension, sedation doses in patients older than 70 years of age, allergic reactions and laryngospasm⁄bronchospasm; procedure-related early - perforation, immediate postpolypectomy bleeding, need for hospital admission or transfer to emergency department from the gastroenterology unit, instrument impaction, severe persistent abdominal pain requiring evaluation proven to not be perforation; and procedure-related delayed - death within 30 days of procedure, 14-day unplanned hospitalization, 14-day unplanned contact with a health provider, gastrointestinal bleeding within 14 days of procedure, infection or symptomatic metabolic complications. The 19 indicators of safety compromise in endoscopy, identified by a rigorous, evidence-based consensus process, provide clear outcomes to be recorded by all facilities as part of their continuing quality improvement programs.

  17. Hot-air balloon tours: crash epidemiology in the United States, 2000-2011.

    PubMed

    Ballard, Sarah-Blythe; Beaty, Leland P; Baker, Susan P

    2013-11-01

    Hot-air balloon tours are FAR Part 91-governed balloon rides conducted for compensation or hire. Part 91, General Aviation, in general involves the least strict federal regulations and accounts for the majority of aviation crashes and fatalities. National Transportation Safety Board reports of hot-air balloon tour crashes in the United States from 2000 through 2011 were read and analyzed. During the 12-yr period, 78 hot-air balloon tours crashed, involving 518 occupants. There were 91 serious injuries and 5 fatalities; 83% of crashes resulted in one or more serious or fatal outcomes. Of the serious injuries characterized, 56% were lower extremity fractures. Most crashes (81%) occurred during landing; 65% involved hard landings. Fixed object collisions contributed to 50% of serious injuries and all 5 fatalities. During landing sequences, gondola dragging, tipping, bouncing, and occupant ejection were associated with poor outcomes. Of the crashes resulting in serious or fatal outcomes, 20% of balloons were significantly damaged or destroyed. The incidence of morbidity and mortality is high among hot-air balloon tour crashes, and the proportion of balloon crashes attributed to paid rides appears to have increased over time. In addition to examining the role of restraint systems, personal protective equipment, and power line emergency procedures in ballooning, injury prevention efforts should target factors such hard landings, object strikes, gondola instability, and occupant ejections, which are associated with balloon injuries and deaths. Crash outcomes may also improve with vehicle engineering that enables balloons themselves to absorb impact forces.

  18. Coronary artery stent (image)

    MedlinePlus

    ... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open. ... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open.

  19. Fasting and meal-induced CCK and PP secretion following intragastric balloon treatment for obesity.

    PubMed

    Mathus-Vliegen, Elisabeth M H; de Groot, Gerrit H

    2013-05-01

    Satiety is centrally and peripherally mediated by gastrointestinal peptides and the vagal nerve. We aimed to investigate whether intragastric balloon treatment affects satiety through effects on fasting and meal-stimulated cholecystokinin (CCK) and pancreatic polypeptide (PP) secretion. Patients referred for obesity treatment were randomised to 13 weeks of sham treatment followed by 13 weeks of balloon treatment (group 1; sham/balloon) or to twice a 13-week period of balloon treatment (group 2; balloon/balloon). Blood samples were taken for fasting and meal-stimulated CCK and PP levels at the start (T0) and after 13 (T1) and 26 (T2) weeks. Patients filled out visual analogue scales (VAS) to assess satiety. Forty-two patients (35 females, body weight 125.1 kg, BMI 43.3 kg/m(2)) participated. In group 1, basal CCK levels decreased but meal-stimulated response remained unchanged after 13 weeks of sham treatment. In group 2, basal and meal-stimulated CCK levels decreased after 13 weeks of balloon treatment. At the end of the second 13-week period, when group 1 had their first balloon treatment, they duplicated the initial 13-week results of group 2, whereas group 2 continued their balloon treatment and reduced meal-stimulated CCK release. Both groups showed reduced meal-stimulated PP secretions at T1 and T2 compared to T0. Changes in diet composition and VAS scores were similar. Improvements in glucose homeostasis partly explained the PP results. The reduced CCK and PP secretion after balloon positioning was unexpected and may reflect delayed gastric emptying induced by the balloon. Improved glucose metabolism partly explained the reduced PP secretion. Satiety and weight loss were not adversely influenced by these hormonal changes.

  20. Endourological treatment of nonmalignant upper urinary tract complications after urinary diversion.

    PubMed

    El-Nahas, Ahmed R; Shokeir, Ahmed A

    2010-12-01

    Endourological modalities are considered the first line of treatment for benign ureterointestinal anastomotic strictures except in long strictures, completely obliterated lumen, prior radiation, and poor renal function. Endoureterotomy provided better success than balloon dilatation. In poor-operative risk patients, metal or double-J stents are viable options. Endourological treatments of upper tract stones after diversion are indicated for stones not suitable for shock wave lithotripsy (SWL) or to salvage SWL failure. Percutaneous nephrolithotomy was preferred for large or complex renal stones, whereas ureteroscopy was used for smaller stones. The evaluation of stone-free status and regular follow-up are mandatory because of the high recurrence rate. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    PubMed

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  2. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    PubMed

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. The effect of transient balloon occlusion of the mitral valve on left atrial appendage blood flow velocity and spontaneous echo contrast.

    PubMed

    Wang, J; Chung Ann Choo, D; Zhang, X; Yang, Q; Xian, T; Lu, D; Jiang, S

    2000-07-01

    Spontaneous echo contrast (SEC) is a phenomenon that is commonly seen in areas of blood stasis. It is a slowly moving, cloud-like swirling pattern of "smoke" or increased echogenicity recorded on echocardiography. SEC is commonly seen in the left atrium of patients with mitral stenosis or atrial fibrillation. The presence of SEC has been shown to be a marker of increased thromboembolic risk. By using transesophageal echocardiography during percutaneous balloon mitral valvotomy (PBMV), the study investigated the relationship between SEC and varying left atrial appendage (LAA) blood flow velocity in the human heart. Thirty-five patients with rheumatic mitral stenosis underwent percutaneous balloon mitral valvotomy with intraoperative transesophageal echocardiography monitoring. We alternatively measured LAA velocities and observed the left atrium for various grades of SEC (0 = none to 4 = severe) before and after each balloon inflation. Left atrial appendage maximal ejection velocity was reduced from 35 +/- 14 to 6 +/- 2 mm/s at peak balloon inflation and increased to 40 +/- 16 mm/s after balloon deflation. In comparison with the values before balloon inflation and after balloon deflation, LAA velocities were significantly lower (p < 0.001). New or increased SEC grade was observed during 54 of 61 (88%) inflations and unchanged in 7 (12%) inflations at peak balloon inflation. Spontaneous echo contrast became lower in grade after 55 balloon deflations (90%), completely disappeared after 18 deflations (30%), and remained unchanged after 6 deflations (10%). The mean time to achieve maximal SEC grade (2.5 +/- 1.2 s) coincided with the mean time to trough LAA velocities (2.3 +/- 1.1 s) after balloon inflation. Upon deflation, the mean time to lowest SEC grade (2.9 +/- 1.8 s) coincided with mean time to achieve maximal LAA velocities (2.7 +/- 1.6 s). During balloon inflation, the severity of SEC was enhanced with corresponding reduction in LAA flow velocity. Upon balloon deflation, SEC lightens or disappears with increase in LAA flow velocity.

  4. Predictable pollution: an assessment of weather balloons and associated impacts on the marine environment--an example for the Great Barrier Reef, Australia.

    PubMed

    O'Shea, Owen R; Hamann, Mark; Smith, Walter; Taylor, Heidi

    2014-02-15

    Efforts to curb pollution in the marine environment are covered by national and international legislation, yet weather balloons are released into the environment with no salvage agenda. Here, we assess impacts associated with weather balloons in the Great Barrier Reef World Heritage Area (GBRWHA). We use modeling to assess the probability of ocean endpoints for released weather balloons and predict pathways post-release. In addition, we use 21 months of data from beach cleanup events to validate our results and assess the abundance and frequency of weather balloon fragments in the GBRWHA. We found between 65% and 70% of balloons land in the ocean and ocean currents largely determine final endpoints. Beach cleanup data revealed 2460 weather balloon fragments were recovered from 24 sites within the GBRWHA. This is the first attempt to quantify this problem and these data will add support to a much-needed mitigation strategy for weather balloon waste. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Malignant Esophagogastric Junction Obstruction: Efficacy of Balloon Dilation Combined with Chemotherapy and/or Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ko, Gi-Young; Song, Ho-Young, E-mail: hysong@amc.seoul.kr; Hong, Heuk-Jin

    2003-04-15

    Purpose: To assess the efficacy of balloon dilation combined with chemotherapy and/or radiation therapy for palliation of dysphagia due to malignant esophagogastric junction strictures. Methods: Fluoroscopically guided balloon dilation was attempted in 20 patients. The causes of strictures were gastric adenocarcinoma (n = 10) and esophageal squamous cell carcinoma (n = 10). Scheduled chemotherapy and/or radiation therapy followed balloon dilation in all patients. Results: There were no technical failures or major complications. After balloon dilation, 15 (75%) patients showed improvement of dysphagia. No patient complained of reflux esophagitis during the follow-up period. Among the 15 patients, seven needed no furthermore » treatment for palliation of dysphagia until their deaths. The remaining eight patients underwent repeat balloon dilation(n = 4) or stent placement (n = 4)3-43 weeks (mean 15 weeks) after the initial balloon dilation because of recurrent dysphagia. Conclusion: Balloon dilation combined with chemotherapy and/or radiation therapy seems to be an easy and reasonably effective palliative treatment for malignant esophagogastric strictures.« less

  6. Evaluation of a multimedia information system for endoscopy

    NASA Astrophysics Data System (ADS)

    Enning, C. John W.; Siersema, Peter D.; van Blankenstein, Mark; van Boven, Gert-Jan; van Gennip, Elisabeth M.

    1996-05-01

    In a cooperation between the University Hospital Rotterdam (AZR) and HISCOM, HIS supplier, a multimedia information system for endoscopy (ENSIS) has been developed in a project funded by the Dutch Ministry of Health Care. An integral part of this project was an evaluation of costs and effects of this system. The system has been implemented on the gastroenterology department and the internal medicine ward in the AZR. The results indicate that the anatomical knowledge of requesting physicians improved with the system. Both the response time and availability of endoscopy images improved greatly. Because of the use of off-the-shelve technology (possible because of the relatively small resolution requirements of endoscopy images) ENSIS can be implemented at relatively low costs.

  7. Capsule endoscopy: no longer limited to the small bowel.

    PubMed

    Niv, Yaron

    2010-03-01

    Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.

  8. Operative endoscopy of the airway

    PubMed Central

    Walters, Dustin M.

    2016-01-01

    Airway endoscopy has long been an important and useful tool in the management of thoracic diseases. As thoracic specialists have gained experience with both flexible and rigid bronchoscopic techniques, the technology has continued to evolve so that bronchoscopy is currently the foundation for diagnosis and treatment of many thoracic ailments. Airway endoscopy plays a significant role in the biopsy of tumors within the airways, mediastinum, and lung parenchyma. Endoscopic methods have been developed to treat benign and malignant airway stenoses and tracheomalacia. And more recently, techniques have been conceived to treat end-stage emphysema and prolonged air leaks in select patients. This review describes the abundant uses of airway endoscopy, as well as technical considerations and limitations of the current technologies. PMID:26981263

  9. Improved techniques for double-balloon-enteroscopy-assisted endoscopic retrograde cholangiopancreatography

    PubMed Central

    Osoegawa, Takashi; Motomura, Yasuaki; Akahoshi, Kazuya; Higuchi, Naomi; Tanaka, Yoshimasa; Hisano, Terumasa; Itaba, Souichi; Gibo, Junya; Yamada, Mariko; Kubokawa, Masaru; Sumida, Yorinobu; Akiho, Hirotada; Ihara, Eikichi; Nakamura, Kazuhiko

    2012-01-01

    AIM: To investigate the clinical outcome of double balloon enteroscopy (DBE)-assisted endoscopic retrograde cholangiopancreatography (DB-ERCP) in patients with altered gastrointestinal anatomy. METHODS: Between September 2006 and April 2011, 47 procedures of DB-ERCP were performed in 28 patients with a Roux-en-Y total gastrectomy (n = 11), Billroth II gastrectomy (n = 15), or Roux-en-Y anastomosis with hepaticojejunostomy (n = 2). DB-ERCP was performed using a short-type DBE combined with several technical innovations such as using an endoscope attachment, marking by submucosal tattooing, selectively applying contrast medium, and CO2 insufflations. RESULTS: The papilla of Vater or hepaticojejunostomy site was reached in its entirety with a 96% success rate (45/47 procedures). There were no significant differences in the success rate of reaching the blind end with a DBE among Roux-en-Y total gastrectomy (96%), Billroth II reconstruction (94%), or pancreatoduodenectomy (100%), respectively (P = 0.91). The total successful rate of cannulation and contrast enhancement of the target bile duct in patients whom the blind end was reached with a DBE was 40/45 procedures (89%). Again, there were no significant differences in the success rate of cannulation and contrast enhancement of the target bile duct with a DBE among Roux-en-Y total gastrectomy (88 %), Billroth II reconstruction (89%), or pancreatoduodenectomy (100%), respectively (P = 0.67). Treatment was achieved in all 40 procedures (100%) in patients whom the contrast enhancement of the bile duct was successful. Common endoscopic treatments were endoscopic biliary drainage (24 procedures) and extraction of stones (14 procedures). Biliary drainage was done by placement of plastic stents. Stones extraction was done by lithotomy with the mechanical lithotripter followed by extraction with a basket or by the balloon pull-through method. Endoscopic sphincterotomy was performed in 14 procedures with a needle precutting knife using a guidewire. The mean total duration of the procedure was 93.6 ± 6.8 min and the mean time required to reach the papilla was 30.5 ± 3.7 min. The mean time required to reach the papilla tended to be shorter in Billroth II reconstruction (20.9 ± 5.8 min) than that in Roux-en-Y total gastrectomy (37.1 ± 4.9 min) but there was no significant difference (P = 0.09). A major complication occurred in one patient (3.5%); perforation of the long limb in a patient with Billroth II anastomosis. CONCLUSION: Short-type DBE combined with several technical innovations enabled us to perform ERCP in most patients with altered gastrointestinal anatomy. PMID:23239923

  10. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    PubMed

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon deflation are needed to facilitate controlled reperfusion following REBOA.

  11. Mobile, high-wind, balloon-launching apparatus

    NASA Technical Reports Server (NTRS)

    Rust, W. David; Marshall, Thomas C.

    1989-01-01

    In order to place instruments for measuring meteorological and electrical parameters into thunderstorms, an inexpensive apparatus has been developed which makes it possible to inflate, transport, and launch balloons in high winds. The launching apparatus is a cylinder of bubble plastic that is made by joining the sides of the cylinder together with a velcro rip strip. A balloon is launched by pulling the rip strip rapidly. This allows the balloon to pop upward into the ambient low-level wind and carry its instrumentation aloft. Different-sized launch tubes are constructed to accommodate particular sizes of balloons. Balloons have been launched in winds of about 20 m/s.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Woong Hee; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Park, Jung-Hun

    Purpose: Little was known about the safety and long-term efficacy of fluoroscopically guided balloon dilation for postintubation tracheal stenosis. The purpose of this study was to evaluate the safety and long-term efficacy of fluoroscopically guided balloon dilation in patients with postintubation tracheal stenosis. Methods: From February 2000 to November 2010, 14 patients underwent fluoroscopically guided balloon dilation for postintubation tracheal stenosis. Technical success, clinical success, and complications were evaluated. Patients were followed up for recurrent symptoms. Results: In all patients, fluoroscopically guided balloon dilation was technically and clinically successful with no major complications. Following the initial procedure, six patients (43more » %) remained asymptomatic during a follow-up period. Obstructive symptoms recurred in eight patients (57 %) within 6 months (mean, 1.7 months), who were treated with repeat balloon dilation (n = 4) and other therapies. Of the four patients who underwent repeat balloon dilation, three became asymptomatic. One patient became asymptomatic after a third balloon dilation. On long-term (mean, 74 months) follow-up, 71 % of patients experienced relief of symptoms following fluoroscopically guided balloon dilation. Conclusions: Fluoroscopically guided balloon dilation may be safe, is easy to perform, and resulted in effective treatment in patients with postintubation tracheal stenosis.« less

  13. Technologies developed by CNES balloon team

    NASA Astrophysics Data System (ADS)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling is made at ZODIAC site (near Toulouse) by Zodiac teams although all mechanical machines belong to CNES. These machines had been developed by CNES to cut, to weld and to thermo-joint the different parts of the balloon.

  14. 78 FR 9785 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-12

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female ACME threaded hose connectors...., Washington, DC 20590. For service information identified in this AD, contact Lindstrand Hot Air Balloons Ltd...

  15. 77 FR 64763 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-23

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... propose to adopt a new airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female... identified in this proposed AD, contact Lindstrand Hot Air Balloons Ltd., Maesbury Road, Oswestry, Shropshire...

  16. 78 FR 18533 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-27

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... Hot Air Balloons Ltd female ACME threaded hose connectors, part numbers HS6139 and HS6144, installed... follows: * * * * * (c) Applicability This AD applies to Lindstrand Hot Air Balloons Ltd female ACME...

  17. False coronary dissection with the new Monorail angioplasty balloon catheter.

    PubMed

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  18. Status report on the activities of National Balloon Facility at Hyderabad

    NASA Astrophysics Data System (ADS)

    Shankarnarayan, Sreenivasan; S, Sreenivasan; Shankarnarayan, Sreenivasan; Manchanda, R. K.; Subba Rao Jonnalagadda, Venkata; Buduru, Suneelkumar

    National balloon facility at Hyderabad has been mandated to provide launch support for Indian and International scientific balloon experiments and also perform the necessary research and development in the design and fabrication of plastic balloons. In the last 4 years, since our last report, NBF has launched many successful balloon flights for the astronomy payloads and a large number of high altitude GPS Sonde flights at different places in the country. We have also continued our efforts on qualification of raw materials for zero-failure performance of our balloons and major focus on upgrading of various facilities and load-line instrumentation for launching from remote sites. We foresee a surge of balloon based experimental activity for in-situ measurements in atmospheric sciences and concept validation payloads for future space based instruments. A new centre for research in Environmental Sciences and Payload Engineering (ESPE) has also been set up at the National Balloon Facility campus to develop and conduct research in various aspects of Environmental sciences in collaboration with other groups, with a specific goal to identify, development of advanced technologies leading to an improved understanding of the earth system. The Payload Engineering facility is geared to the Design and Fabrication of Micro and Nano Satellites and will act as Inter -University Centre for payload fabrication. In this paper we present an overview of the present and planned activities in scientific ballooning at National Balloon Facility Hyderabad.

  19. Balloon-Inflated Catheters for Enteral Feeding: a Word of Caution.

    PubMed

    Dash, Nihar Ranjan; Singh, Anand Narayan; Kilambi, Ragini

    2018-02-01

    Catheters with inflatable balloons such as a Foley catheter may be used for feeding gastrostomy/jejunostomy. The incorrect or improper use of these catheters can have serious consequences. We report 13 cases of feeding jejunostomy with balloon-inflated catheter's malfunction, some referred to our centre and others operated here over a period of 8 years. The most dramatic consequence of such improper use led to rupture of the small intestine due to inadvertent over-inflation (over 100 ml) of the balloon of the catheter during a contrast study. The patient required a laparotomy with resection and anastomosis of the bowel. Three other patients had similar over-inflation of the balloon leading to severe pain and discomfort. In all three patients, timely deflation of the balloon was sufficient to relieve the symptoms. One patient had intussusception with the inflated balloon acting as a lead point. The patient underwent resection of the small bowel with end jejunostomy and distal mucous fistula. All other patients presented with abdominal pain and distension and intestinal obstruction and were managed non-operatively with deflation of balloon either by aspiration, cutting the balloon port or ultrasound-guided puncture of balloon. Healthcare personnel dealing with patients with indwelling catheters must be educated to suspect, detect and manage such problems. The best measure for such unusual complications of otherwise safe devices would be prevention by training and generation of awareness.

  20. Sizing of patent ductus arteriosus in adults for transcatheter closure using the balloon pull-through technique.

    PubMed

    Shafi, Nabil A; Singh, Gagan D; Smith, Thomas W; Rogers, Jason H

    2018-05-01

    To describe a novel balloon sizing technique used during adult transcatheter patent ductus arteriosus (PDA) closure. In addition, to determine the clinical and procedural outcomes in six patients who underwent PDA balloon sizing with subsequent deployment of a PDA occluder device. Transcatheter PDA closure in adults has excellent safety and procedural outcomes. However, PDA sizing in adults can be challenging due to variable defect size, high flow state, or anatomical complexity. We describe a series of six cases where the balloon- pull through technique was successfully performed for PDA sizing prior to transcatheter closure. Consecutive adult patients undergoing adult PDA closure at our institution were studied retrospectively. A partially inflated sizing balloon was pulled through the defect from the aorta into the pulmonary artery and the balloon waist diameter was measured. Procedural success and clinical outcomes were obtained. Six adult patients underwent successful balloon pull-through technique for PDA sizing during transcatheter PDA closure, since conventional angiography often gave suboptimal opacification of the defect. All PDAs were treated with closure devices based on balloon PDA sizing with complete closure and no complications. In three patients that underwent preprocedure computed tomography, the balloon size matched the CT derived measurements. The balloon pull-through technique for PDA sizing is a safe and accurate sizing modality in adults undergoing transcatheter PDA closure. © 2017 Wiley Periodicals, Inc.

  1. Optimum designs for superpressure balloons

    NASA Astrophysics Data System (ADS)

    Smith, M. S.; Rainwater, E. L.

    2004-01-01

    The elastica shape is now well known to be the best basic shape for superpressure balloon design. This shape, also known as the pumpkin, or natural shape for balloons, has been well understood since the early 1900s when it was applied to the determination of the shape of descending parachutes. The elastica shape was also investigated in the 1950s when high strength films were used to produce superpressure cylinder balloons. The need for uniform stress distribution in shells of early superpressure balloons led to a long period of the development of spherical superpressure balloons. Not until the late 1970s was the elastica shape revisited for the purpose of the producing superpressure balloons. This paper will review various development efforts in the field of superpressure design and will elaborate on the current state-of-the-art with suggestions for future developments.

  2. [Imprints of coronary plaque particles in the PTCA balloon surface during the dilatation processing].

    PubMed

    Werner, D; Behrend, D; Schmitz, K P; Urbaszek, W

    1995-05-01

    Seventy-six PTCA-balloons after coronary angioplasty were studied for superficial changes using scanning electron microscopy (SEM) after fixing in glutardialdehyde. Coronary plaque particles were identified on the balloon surface in 52 cases (68%). Twelve new and unused balloons were subjected to the same chemical treatment and SEM showed no imprints. The average length of the longest imprinted plaques was 128 +/- 201 microns and the average number of plaque particles per balloon was 4.9 +/- 2.7. The maximal dilatation pressure and the number of dilatations showed no influence on the impregnation of plaque particles. However, longer plaque imprints tended to occur under low dilatation pressure. Imprints of plaque particles were significantly higher in patients with low cholesterol (p = 0.0001) and low triglycerides (p = 0.0016). No correlation was seen between imprint length and lipid levels. Similarly, the different balloon materials (polyethylene, polyolefincopolymer) showed no significant differences with regard to plaque occurrence. The PTCA-balloons, plaque particles and six coronary plaques obtained after endatherectomy were subjected to energy dispersive x-ray analysis (EDX) under SEM as EDX reveals qualitative and quantitative information about the structural elements. Highly significant differences in calcium, sodium, phosphorus and silicon contents (p = 0.0000) between plaque particles and balloon surface were observed, owing to the absence of these in balloon material. Thus EDX offers additional advantages over SEM in that it clearly differentiates deformed balloon surface, plaque particle, and retained contrast medium. Plaque particles can be recovered from balloon surfaces after PTCA. Depending upon their size, they could lead to coronary spasm or microembolic phenomenon.

  3. Balloon augmented Onyx embolization utilizing a dual lumen balloon catheter: utility in the treatment of a variety of head and neck lesions.

    PubMed

    Spiotta, Alejandro M; Miranpuri, Amrendra S; Vargas, Jan; Magarick, Jordan; Turner, Raymond D; Turk, Aquilla S; Chaudry, M Imran

    2014-09-01

    Endovascular embolization for tumors and vascular malformations has emerged as an important preoperative adjunct prior to resection. We describe the advantages of utilizing a recently released dual lumen balloon catheter for ethylene vinyl alcohol copolymer, also known as Onyx (ev3, Irvine, California, USA), embolization for a variety of head and neck pathologies. A retrospective review of all cases utilizing the Scepter C balloon catheter (MicroVention Inc, Tustin, California, USA) for use in balloon augmented embolization was performed over a 4 month period from October 2012 to February 2013 at the Medical University of South Carolina, Charleston, South Carolina, USA. Charts and angiographic images were reviewed. Representative cases involving diverse pathologies are summarized and illustrate the observed advantages of balloon augmented Onyx embolization with a dual lumen balloon catheter. Balloon augmented Onyx embolization utilizing a novel dual lumen balloon catheter was employed to treat both ruptured and unruptured arteriovenous malformations, intracranial dural arteriovenous fistulae, intracranial neoplasms, carotid body tumors, a thyroid mass, and an extracranial arteriovenous fistula. The dual lumen balloon catheter has several advantages for use with Onyx embolization over older devices, including more efficient proximal plug formation and enhanced navigability for placement deep within the pedicles. The balloon augmented Onyx embolization technique represents a valuable tool to add to the armamentarium of the neurointerventionalist to address a variety of head and neck lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. New concepts for interplanetary balloons and blimps, particularly for Titan

    NASA Astrophysics Data System (ADS)

    Nott, J.

    This paper proposes novel approaches for balloons for planets Titan BALLUTE A balloon or blimp arriving at a planet or moon with an atmosphere might inflate falling under a parachute or after landing Neither is ideal In both cases the envelope must include qualities needed for inflation as well as those for flight A ballute BALLoon parachUTE could be used thus a ballute is like a hot air balloon with a large mouth Initially it fills by ram pressure descending through an atmosphere As proposed it would then be heated by solid propellant It would stop descending and float level with hot air lift It is now a perfect location for inflation without wind or movement through the atmosphere and away from the uncertainties of the surface A ballute could be used over several bodies in the solar system BALLOONS FOR LOW TEMPERATURES Flight in very low temperatures is also discussed Conditions are so different that it is useful to examine basic factors These apply for any planet with low temperature and weather calm enough for balloons or blimps First for terrestrial hot air balloons thermal radiation is usually the dominant way heat is lost But radiation rises with the 4th power of absolute temperature At Titan radiation will be one or two orders of magnitude smaller Also the dense atmosphere allows small balloons small temperature differences So convection is small It appears a hot air balloon can easily be heated by a radioactive source likely carried to make electricity Pinholes are not important in such a balloon

  5. Hot-Air Balloon Tours: Crash Epidemiology in the United States, 2000-2011

    PubMed Central

    Ballard, Sarah-Blythe; Beaty, Leland P.; Baker, Susan P.

    2016-01-01

    Introduction Hot-air balloon tours are FAR Part 91-governed balloon rides conducted for compensation or hire. Part 91, General Aviation, in general involves the least strict federal regulations and accounts for the majority of aviation crashes and fatalities. Methods National Transportation Safety Board reports of hot-air balloon tour crashes in the United States from 2000 through 2011 were read and analyzed. Results During the 12-yr period, 78 hot-air balloon tours crashed, involving 518 occupants. There were 91 serious injuries and 5 fatalities; 83% of crashes resulted in one or more serious or fatal outcomes. Of the serious injuries characterized, 56% were lower extremity fractures. Most crashes (81%) occurred during landing; 65% involved hard landings. Fixed object collisions contributed to 50% of serious injuries and all 5 fatalities. During landing sequences, gondola dragging, tipping, bouncing, and occupant ejection were associated with poor outcomes. Of the crashes resulting in serious or fatal outcomes, 20% of balloons were significantly damaged or destroyed. Discussion The incidence of morbidity and mortality is high among hot-air balloon tour crashes, and the proportion of balloon crashes attributed to paid rides appears to have increased over time. In addition to examining the role of restraint systems, personal protective equipment, and power line emergency procedures in ballooning, injury prevention efforts should target factors such hard landings, object strikes, gondola instability, and occupant ejections, which are associated with balloon injuries and deaths. Crash outcomes may also improve with vehicle engineering that enables balloons themselves to absorb impact forces. PMID:24279231

  6. Experimental characterization and numerical modelling of polymeric film damage, constituting the stratospheric super pressurized balloons

    NASA Astrophysics Data System (ADS)

    Chaabane, Makram; Chaabane, Makram; Dalverny, Olivier; Deramecourt, Arnaud; Mistou, Sébastien

    The super-pressure balloons developed by CNES are a great challenge in scientific ballooning. Whatever the balloon type considered (spherical, pumpkin...), it is necessary to have good knowledge of the mechanical behavior of the envelope regarding to the flight level and the lifespan of the balloon. It appears during the working stages of the super pressure balloons that these last can exploded prematurely in the course of the first hours of flight. For this reason CNES and LGP are carrying out research programs about experimentations and modelling in order to predict a good stability of the balloons flight and guarantee a life time in adequacy with the technical requirement. This study deals with multilayered polymeric film damage which induce balloons failure. These experimental and numerical study aims, are a better understanding and predicting of the damage mechanisms bringing the premature explosion of balloons. The following damages phenomena have different origins. The firsts are simple and triple wrinkles owed during the process and the stocking stages of the balloons. The second damage phenomenon is associated to the creep of the polymeric film during the flight of the balloon. The first experimental results we present in this paper, concern the mechanical characterization of three different damage phenomena. The severe damage induced by the wrinkles of the film involves a significant loss of mechanical properties. In a second part the theoretical study, concerns the choice and the development of a non linear viscoelastic coupled damage behavior model in a finite element code.

  7. Reduction of prostate intrafraction motion using gas-release rectal balloons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su Zhong; Zhao Tianyu; Li Zuofeng

    2012-10-15

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated withmore » the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.« less

  8. Basic development of a small balloon-mounted telemetry and its operation system by university students

    NASA Astrophysics Data System (ADS)

    Yamamoto, Masa-yuki; Kakinami, Yoshihiro; Kono, Hiroki

    In Japan, the high altitude balloon for scientific observation has been continuously launched by JAXA. The balloon has a possibility to reach 50 km altitude without tight environmental condition for onboard equipments, operating with a cost lower than sounding rockets, however, development of the large-scale scientific observation balloons by university laboratories is still difficult. Being coupled with recent improvement of semiconductor sensors, laboratory-basis balloon experiments using small weather balloons has been becoming easily in these years. Owing to an advantage of wide land fields in continental regions, the launch of such small balloons has become to be carried out many times especially in continental countries (e.g. Near Space Ventures, Inc., 2013). Although the balloon is very small as its diameter of 6 feet, excluding its extra buoyancy and the weight of the balloon itself, it is expected that about 2 kg loading capacity is remained for payloads to send it up to about 35 km altitude. However, operation of such balloons in Japan is not in general because precise prediction of a landing area of the payload is difficult, thus high-risk situation for balloon releases is remained. In this study, we aim to achieve practical engineering experiments of weather balloons in Japan to be used for scientific observation within university laboratory level as an educational context. Here we report an approach of developing many devices for a small tethered balloon currently in progress. We evaluated an accuracy of altitude measurement by using a laboratory developed altitude data logger system that consists of a GPS-module and a barometric altimeter. Diameter of the balloon was about 1.4 m. Being fulfilled with about 1440 L helium, it produced buoyancy of about 15.7 N. Taking into account of total weight including the mooring equipments, available payload mass becomes to be about 1100 g. Applying an advantage of a 3D printer of FDM (Fused Deposition Modeling) method with a 3DCAD design software, we designed and manufactured a camera-platform type antenna rotator that automatically track the balloon direction based on the received GPS data as a balloon operation system on ground with automatic controlling software for the tracking system. In order to develop a future telemetry system onboard a small weather balloon, we have performed an onboard data logger system. In this presentation, system configuration of the automatic tracking system will be introduced more in detail. The telemetry system onboard the small balloon is currently under development. We have a plan to send the measured GPS coordinates, temperature, pressure, and humidity data detected by the onboard sensors to ground. A monitoring camera, a 3-axes accelerometer, geomagnetic azimuth measurement, and power monitoring were added to the developed data logger system. The acquired data will be stored in an SD card aboard as well as transmitted to the ground. Using a vacuum chamber with a pressure sensors and a constant-temperature reservoir in laboratory, environmental tests were operated. In this presentation, introducing the data obtained through the development of a prototype balloon system, our recent results and problems will be discussed.

  9. A score card for upper GI endoscopy: Evaluation of interobserver variability in examiners with various levels of experience.

    PubMed

    Neumann, M; Friedl, S; Meining, A; Egger, K; Heldwein, W; Rey, J F; Hochberger, J; Classen, M; Hohenberger, W; Rösch, T

    2002-10-01

    In most European countries, training in GI endoscopy has largely been based on hands-on acquisition of experience in patients rather than on a structured training programme. With the development of training models systematic hands-on training in a variety of diagnostic and therapeutic endoscopy techniques was achieved. Little, however, is known about methods of objectively assessing trainees' performance. We therefore developed an assessment 'score card' for upper GI endoscopy and tested it in endoscopists with various levels of experience. The aim of the study was therefore to assess interobserver variations in the evaluation of trainees. On the basis of textbook and expert opinions a consensus group of eight experienced endoscopists developed a score card for diagnostic upper GI endoscopy with biopsy. The score card includes an assessment of the single steps of the procedure as well as of the times needed to complete each step. This score card was then evaluated in a further conference including ten experts who blindly assessed videotapes of 15 endoscopists performing upper GI endoscopy in a training bio-simulation model (the 'Erlangen Endo-Trainer'). On the basis of their previous experience (i. e. the number of endoscopies performed) these 15 endoscopists were classified into four groups: very experienced, experienced, having some experience and inexperienced. Interobserver variability (IOV) was tested for the various score card parameters (Kendall's rank-correlation coefficient 0.0-0.5 poor, 0.5-1.0 good agreement). In addition, the correlation between the score card assessment and the examiners' experience levels was analysed. Despite poor IOV results for all the parameters tested (Kendall coefficient < 0.3), the assessment parameters correlated well when the examiners' different experience levels were taken into account (correlation coefficient 0.59-0.89, p < 0.05). The score card parameters were suitable for differentiating between the four groups of examiners with different levels of endoscopic experience. As expected with scores involving subjective assessment of performance, the variability between reviewers was substantial. Nevertheless, the assessment score was capable of distinguishing reliably between different experience levels in terms of a good individual observer consistency. The score card can therefore be used to document both training status and progress during endoscopy training courses using bio-simulation models, and this might be able to provide improved quality assurance in GI endoscopy training.

  10. 14 CFR 61.115 - Balloon rating: Limitations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... takes a practical test in a balloon with an airborne heater: (1) The pilot certificate will contain a limitation restricting the exercise of the privileges of that certificate to a balloon with an airborne... removed when the person obtains the required aeronautical experience in a balloon with an airborne heater...

  11. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  12. 14 CFR 31.49 - Control systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...

  13. 14 CFR 31.49 - Control systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...

  14. 14 CFR 31.49 - Control systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...

  15. 14 CFR 31.49 - Control systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... (c) Each balloon using a captive gas as the lifting means must have an automatic valve or appendix... STANDARDS: MANNED FREE BALLOONS Design Construction § 31.49 Control systems. (a) Each control must operate... minute when the balloon is at its maximum operating pressure. (d) Each hot air balloon must have a means...

  16. 78 FR 6838 - Certain Balloon Dissection Devices and Products Containing Same; Institution of Investigation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-31

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-865] Certain Balloon Dissection Devices... the United States after importation of certain dissection balloons and products containing the same by... importation of certain dissection balloons and products containing the same that infringe one or more of...

  17. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  18. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  19. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  20. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  1. 14 CFR 61.3 - Requirement for certificates, ratings, and authorizations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... with a glider category rating, a balloon class rating, or glider or balloon privileges; (ii) Is... than glider or balloon privileges and holds a U.S. driver's license; (iii) Is exercising the privileges... exercising the privileges of a sport pilot certificate with glider or balloon privileges; (v) Is exercising...

  2. 14 CFR 61.3 - Requirement for certificates, ratings, and authorizations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... with a glider category rating, a balloon class rating, or glider or balloon privileges; (ii) Is... than glider or balloon privileges and holds a U.S. driver's license; (iii) Is exercising the privileges... exercising the privileges of a sport pilot certificate with glider or balloon privileges; (v) Is exercising...

  3. 14 CFR 61.3 - Requirement for certificates, ratings, and authorizations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... with a glider category rating, a balloon class rating, or glider or balloon privileges; (ii) Is... than glider or balloon privileges and holds a U.S. driver's license; (iii) Is exercising the privileges... exercising the privileges of a sport pilot certificate with glider or balloon privileges; (v) Is exercising...

  4. Comparison of 3 mm versus 4 mm rigid endoscope in diagnostic nasal endoscopy.

    PubMed

    Neel, Gregory S; Kau, Ryan L; Bansberg, Stephen F; Lal, Devyani

    2017-03-01

    Compare nasal endoscopy with 3 mm versus conventional 4 mm rigid 30° endoscopes for visualization, patient comfort, and examiner ease. Ten adults with no previous sinus surgery underwent bilateral nasal endoscopy with both 4 mm and 3 mm endoscopes (resulting in 20 paired nasal endoscopies). Visualization, patient discomfort and examiner's difficulty were assessed with every endoscopy. Sino-nasal structures were checked on a list if visualized satisfactorily. Patients rated discomfort on a standardized numerical pain scale (0-10). Examiners rated difficulty of examination on a scale of 1-5 (1 = easiest). Visualization with 3 mm endoscope was superior for the sphenoid ostium ( P  = 0.002), superior turbinate ( P  = 0.007), spheno-ethmoid recess ( P  = 0.006), uncinate process ( P  = 0.002), cribriform area ( P  = 0.007), and Valve of Hasner ( P  = 0.002). Patient discomfort was not significantly different for 3 mm vs. 4 mm endoscopes but correlated with the examiners' assessment of difficulty ( r  = 0.73). The examiner rated endoscopy with 4 mm endoscopes more difficult ( P  = 0.027). The 3 mm endoscope was superior in visualizing the sphenoid ostium, superior turbinate, spheno-ethmoid recess, uncinate process, cribriform plate, and valve of Hasner. It therefore may be useful in assessment of spheno-ethmoid recess, nasolacrimal duct, and cribriform area pathologies. Overall, patients tolerated nasal endoscopy well. Though patient discomfort was not significantly different between the endoscopes, most discomfort with 3 mm endoscopes was noted while examining structures difficult to visualize with the 4 mm endoscope. Patients' discomfort correlated with the examiner's assessment of difficulty.

  5. Endoscopy in neutropenic and/or thrombocytopenic patients

    PubMed Central

    Tong, Michelle C; Tadros, Micheal; Vaziri, Haleh

    2015-01-01

    AIM: To evaluate the safety of endoscopic procedures in neutropenic and/or thrombocytopenic cancer patients. METHODS: We performed a literature search for English language studies in which patients with neutropenia and/or thrombocytopenia underwent endoscopy. Studies were included if endoscopic procedures were used as part of the evaluation of neutropenic and/or thrombocytopenic patients, yielding 13 studies. Two studies in which endoscopy was not a primary evaluation tool were excluded. Eleven relevant studies were identified by two independent reviewers on PubMed, Scopus, and Ovid databases. RESULTS: Most of the studies had high diagnostic yield with relatively low complication rates. Therapeutic endoscopic interventions were performed in more than half the studies, including high-risk procedures, such as sclerotherapy. Platelet transfusion was given if counts were less than 50000/mm3 in four studies and less than 10000/mm3 in one study. Other thrombocytopenic precautions included withholding of biopsy if platelet count was less than 30000/mm3 in one study and less than 20000/mm3 in another study. Two of the ten studies which examined thrombocytopenic patient populations reported bleeding complications related to endoscopy, none of which caused major morbidity or mortality. All febrile neutropenic patients received prophylactic broad-spectrum antibiotics in the studies reviewed. Regarding afebrile neutropenic patients, prophylactic antibiotics were given if absolute neutrophil count was less than 1000/mm3 in one study, if the patient was undergoing colonoscopy and had a high inflammatory condition without clear definition of significance in another study, and if the patient was in an aplastic phase in a third study. Endoscopy was also withheld in one study for severe pancytopenia. CONCLUSION: Endoscopy can be safely performed in patients with thrombocytopenia/neutropenia. Prophylactic platelet transfusion and/or antibiotic administration prior to endoscopy may be considered in some cases and should be individualized. PMID:26674926

  6. Capsule endoscopy in the diagnosis of Crohn's disease.

    PubMed

    Niv, Yaron

    2013-01-01

    Crohn's disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn's disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn's disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn's disease. Recently, we have developed and validated the Capsule Endoscopy Crohn's Disease Activity Index (also known as the Niv score) for Crohn's disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn's ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn's disease.

  7. High definition versus standard definition white light endoscopy for detecting dysplasia in patients with Barrett's esophagus.

    PubMed

    Sami, S S; Subramanian, V; Butt, W M; Bejkar, G; Coleman, J; Mannath, J; Ragunath, K

    2015-01-01

    High-definition endoscopy systems provide superior image resolution. The aim of this study was to assess the utility of high definition compared with standard definition endoscopy system for detecting dysplastic lesions in patients with Barrett's esophagus. A retrospective cohort study of patients with non-dysplastic Barrett's esophagus undergoing routine surveillance was performed. Data were retrieved from the central hospital electronic database. Procedures performed for non-surveillance indications, Barrett's esophagus Prague C0M1 classification with no specialized intestinal metaplasia on histology, patients diagnosed with any dysplasia or cancer on index endoscopy, and procedures using advanced imaging techniques were excluded. Logistic regression models were constructed to estimate adjusted odds ratios and 95% confidence intervals comparing outcomes with standard definition and high-definition systems. The high definition was superior to standard definition system in targeted detection of all dysplastic lesions (odds ratio 3.27, 95% confidence interval 1.27-8.40) as well as overall dysplasia detected on both random and target biopsies (odds ratio 2.36, 95% confidence interval 1.50-3.72). More non-dysplastic lesions were detected with the high-definition system (odds ratio 1.16, 95% confidence interval 1.01-1.33). There was no difference between high definition and standard definition endoscopy in the overall (random and target) high-grade dysplasia or cancers detected (odds ratio 0.93, 95% confidence interval 0.83-1.04). Trainee endoscopists, number of biopsies taken, and male sex were all significantly associated with a higher yield for dysplastic lesions. The use of the high-definition endoscopy system is associated with better targeted detection of any dysplasia during routine Barrett's esophagus surveillance. However, high-definition endoscopy cannot replace random biopsies at present time. © 2014 International Society for Diseases of the Esophagus.

  8. Outcomes of patients hospitalized with peptic ulcer disease diagnosed in acute upper endoscopy.

    PubMed

    Malmi, Hanna; Kautiainen, Hannu; Virta, Lauri J; Färkkilä, Martti A

    2017-11-01

    The incidence and complications of peptic ulcer disease (PUD) have declined, but mortality from bleeding ulcers has remained unchanged. The aims of the current study were to evaluate the significance of PUD among patients admitted for acute upper endoscopy and to evaluate the survival of PUD patients. In this prospective, observational cohort study, data on 1580 acute upper endoscopy cases during 2012-2014 were collected. A total of 649 patients were included with written informed consent. Data on patients' characteristics, living habits, comorbidities, drug use, endoscopy and short-term and long-term survival were collected. Of all patients admitted for endoscopy, 147/649 (23%) had PUD with the main symptom of melena. Of these PUD patients, 35% had major stigmata of bleeding (Forrest Ia-IIb) in endoscopy. Patients with major stigmata had significantly more often renal insufficiency, lower level of blood pressure with tachycardia and lower level of haemoglobin, platelets and ratio of thromboplastin time. No differences in drug use, Charlson comorbidity class, BMI, smoking or alcohol use were found. Of the PUD patients, 31% were Helicobacter pylori positive. The 30-day mortality was 0.7% (95% confidence interval: 0.01-4.7), 1-year mortality was 12.9% (8.4-19.5) and the 2-year mortality was 19.4% (13.8-26.8), with no difference according to major or minor stigmata of bleeding. Comorbidity (Charlson>1) was associated with decreased survival (P=0.029) and obesity (BMI≥30) was associated with better survival (P=0.023). PUD is still the most common cause for acute upper endoscopy with very low short-term mortality. Comorbidity, but not the stigmata of bleeding, was associated with decreased long-term survival.

  9. Parental and youth understanding of the informed consent process for pediatric endoscopy.

    PubMed

    Jubbal, Kevin; Chun, Stanford; Chang, Jeremy; Zhang, Sherry; Terrones, Laura; Huang, Jeannie S

    2015-06-01

    Informed consent (IC) is an essential communication between patient/representative and physician that acknowledges patient autonomy; assent is the equivalent process performed between youth and physician. For clinical procedures involving youth, only the IC process between guardian/parent and physician is required to be performed. Nevertheless, experts recommend that youth undergo assent whenever possible. In the present study, we explored both parental and youth understanding of required IC elements in IC discussions before pediatric endoscopy. Following signing of IC documents on the day of endoscopy at a tertiary care academic medical center, youth and their parents underwent structured interviews to assess comprehension of key elements of the IC process. A total of 88 children and adolescents and their parents were evaluated. Two youth and 12 parents demonstrated comprehensive understanding of key IC elements for pediatric endoscopy. Suboptimal youth understanding was demonstrated for nature of the procedure (25% with adequate understanding) and related risks (17%), and alternatives (14%) to the procedure. Suboptimal parental understanding was demonstrated for procedure alternatives (24%). Youth overall understanding of IC varied by age, whereas parental global understanding of IC varied by physician. Understanding of IC performed for pediatric endoscopy could be improved in both parents and youth. Our findings suggest that interventions targeting parents, youth, and physicians may be helpful. Further study is needed to determine whether our findings are representative of IC understanding at other pediatric endoscopy centers.

  10. Virtual chromoendoscopy improves the diagnostic yield of small bowel capsule endoscopy in obscure gastrointestinal bleeding.

    PubMed

    Boal Carvalho, Pedro; Magalhães, Joana; Dias de Castro, Francisca; Gonçalves, Tiago Cúrdia; Rosa, Bruno; Moreira, Maria João; Cotter, José

    2016-02-01

    Small bowel capsule endoscopy represents the initial investigation for obscure gastrointestinal bleeding. Flexible spectral imaging colour enhancement (FICE) is a virtual chromoendoscopy technique designed to enhance mucosal lesions, available in different settings according to light wavelength-- FICE1, 2 and 3. To compare the diagnostic yield of FICE1 and white light during capsule endoscopy in patients with obscure gastrointestinal bleeding. Retrospective single-centre study including 60 consecutive patients referred for small bowel capsule endoscopy for obscure gastrointestinal bleeding. Endoscopies were independently reviewed in FICE1 and white light; findings were then reviewed by another researcher, establishing a gold standard. Diagnostic yield was defined as the presence of lesions with high bleeding potential (P2) angioectasias, ulcers or tumours. Diagnostic yield using FICE1 was significantly higher than white light (55% vs. 42%, p=0.021). A superior number of P2 lesions was detected with FICE1 (74 vs. 44, p=0.003), particularly angioectasias (54 vs. 26, p=0.002), but not ulcers or tumours. FICE1 was significantly superior to white light, resulting in a 13% improvement in diagnostic yield, and potentially bleeding lesions particularly angioectasias were more often observed. Our results support the use of FICE1 while reviewing small bowel capsule endoscopy for obscure gastrointestinal bleeding. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Severe Sunburn After a Hot Air Balloon Ride: A Case Report and Literature Review.

    PubMed

    Ozturk, Sinan; Karagoz, Huseyin

    2015-01-01

    Hot air balloon tours are very popular among travelers worldwide. Preventable burn injuries associated with hot air balloon rides have been reported during crashes into power lines, in propane burner explosions, and following contact with the propane burner tanks. We present a case of severe repeated sunburn, which poses another risk of preventable injury during hot air balloon rides, and briefly discuss the injury epidemiology of hot air balloon rides. © 2015 International Society of Travel Medicine.

  12. Barrett esophagus

    MedlinePlus

    ... risk for cancer in the area involved. However, cancer is not common. ... endoscopy to look for cell changes that indicate cancer. People with Barrett esophagus are recommended to have follow-up endoscopy every ...

  13. International Digestive Endoscopy Network 2014: Turnpike to the Future

    PubMed Central

    Kim, Eun Young; Kwon, Kwang An; Choi, Il Ju; Ryu, Ji Kon

    2014-01-01

    Social networks are useful in the study of relationships between individuals or entire populations, and the ties through which any given social unit connects. Those represent the convergence of the various social contacts of that unit. Consequently, the term "social networking service" (SNS) became extremely familiar. Similar to familiar SNSs, International Digestive Endoscopy Network (IDEN) 2014 was based on an international network composed of an impressive 2-day scientific program dealing with a variety of topics for gastrointestinal (GI) diseases, which connects physicians and researchers from all over the world. The scientific programs included live endoscopic demonstrations and provided cutting-edge information and practice tips as well as the latest advances concerning upper GI, lower GI, and pancreatobiliary endoscopy. IDEN 2014 featured American Society for Gastrointestinal Endoscopy-Korean Society of Gastrointestinal Endoscopy (ASGE-KSGE)-joint sessions prepared through cooperation between ASGE and KSGE. Furthermore, IDEN 2014 provided a special program for young scientists called the 'Asian Young Endoscopist Award Forum' to foster networks, with many young endoscopists from Asian countries taking an active interest and participation. PMID:25324994

  14. International digestive endoscopy network 2014: turnpike to the future.

    PubMed

    Kim, Eun Young; Kwon, Kwang An; Choi, Il Ju; Ryu, Ji Kon; Hahm, Ki Baik

    2014-09-01

    Social networks are useful in the study of relationships between individuals or entire populations, and the ties through which any given social unit connects. Those represent the convergence of the various social contacts of that unit. Consequently, the term "social networking service" (SNS) became extremely familiar. Similar to familiar SNSs, International Digestive Endoscopy Network (IDEN) 2014 was based on an international network composed of an impressive 2-day scientific program dealing with a variety of topics for gastrointestinal (GI) diseases, which connects physicians and researchers from all over the world. The scientific programs included live endoscopic demonstrations and provided cutting-edge information and practice tips as well as the latest advances concerning upper GI, lower GI, and pancreatobiliary endoscopy. IDEN 2014 featured American Society for Gastrointestinal Endoscopy-Korean Society of Gastrointestinal Endoscopy (ASGE-KSGE)-joint sessions prepared through cooperation between ASGE and KSGE. Furthermore, IDEN 2014 provided a special program for young scientists called the 'Asian Young Endoscopist Award Forum' to foster networks, with many young endoscopists from Asian countries taking an active interest and participation.

  15. Feasibility of real‐time near‐infrared indocyanine green fluorescence endoscopy for the evaluation of mucosal head and neck lesions

    PubMed Central

    Schmidt, Florian; Dittberner, Andreas; Koscielny, Sven; Petersen, Iver

    2016-01-01

    Abstract Background The purpose of this study was to explore the feasibility and potential drawbacks of near‐infrared (NIR) endoscopy with indocyanine green (ICG) to examine mucosal head and neck lesions. Methods NIR ICG endoscopy was applied to image head and neck cancer epithelium in vivo. The evaluation of the ICG videos was performed off‐line independently by 2 evaluators and blinded with respect to final histopathological results from biopsies taken as the gold standard. Results Forty percent of the lesions from 55 patients were histologically malignant. ICG positivity showed a sensitivity, specificity, and accuracy to be related to a malignant tumor of 90.5%, 90.9%, and 89.1%, respectively. The kappa index for the interobserver assessment showed a 94.4% agreement for the assessment of the ICG positivity. Side effects of the NIR ICG endoscopy did not arise. Conclusion NIR ICG endoscopy in patients with mucosal head and neck lesions was feasible and safe. It might help intraoperatively to differentiate benign from malignant lesions. © 2016 Wiley Periodicals, Inc. Head Neck 39: 234–240, 2017 PMID:27590351

  16. Image Quality Analysis of Various Gastrointestinal Endoscopes: Why Image Quality Is a Prerequisite for Proper Diagnostic and Therapeutic Endoscopy

    PubMed Central

    Ko, Weon Jin; An, Pyeong; Ko, Kwang Hyun; Hahm, Ki Baik; Hong, Sung Pyo

    2015-01-01

    Arising from human curiosity in terms of the desire to look within the human body, endoscopy has undergone significant advances in modern medicine. Direct visualization of the gastrointestinal (GI) tract by traditional endoscopy was first introduced over 50 years ago, after which fairly rapid advancement from rigid esophagogastric scopes to flexible scopes and high definition videoscopes has occurred. In an effort towards early detection of precancerous lesions in the GI tract, several high-technology imaging scopes have been developed, including narrow band imaging, autofocus imaging, magnified endoscopy, and confocal microendoscopy. However, these modern developments have resulted in fundamental imaging technology being skewed towards red-green-blue and this technology has obscured the advantages of other endoscope techniques. In this review article, we have described the importance of image quality analysis using a survey to consider the diversity of endoscope system selection in order to better achieve diagnostic and therapeutic goals. The ultimate aims can be achieved through the adoption of modern endoscopy systems that obtain high image quality. PMID:26473119

  17. Ethical issues in therapeutic endoscopy - can communication between patient and physician make a difference?

    PubMed

    Zorilă, Marian Valentin; Ungureanu, Bogdan Silviu; Zăvoi, Roxana Eugenia; Ciurea, Marius Eugen; Gheonea, Dan Ionuţ

    2015-01-01

    Therapeutic endoscopy represents a major step in evidence-based medicine with great potential in the evolution of non-invasive surgery. The evolutionary status of endoscopy has reached a level where some of the surgical intervention can be performed in a minimal invasive way, with great benefits for the patient. However, this rises up some ethical issues regarding the patient's comfort zone, possible risks and complications and subjected the physician to possible litigation situations if not well trained. A rather good interaction and communication between patient and endoscopist is mandatory, as the health-care experience might be more satisfying. Unfortunate situations may also be avoided if intensive training and up to date knowledge and skills are acquired before jumping to therapeutic endoscopy. The continuous development and general focus on interventional endoscopy seems to have a key role on current medical standings. Therefore, in the following paper we have tried to underline the potential ethical problems that both the patient and the physician should take into consideration towards a better therapeutic endoscopic result.

  18. Balloon concepts for scientific investigation of Mars and Jupiter

    NASA Technical Reports Server (NTRS)

    Ash, R. L.

    1979-01-01

    Opportunities for scientific investigation of the atmospheric planets using buoyant balloons have been explored. Mars and Jupiter were considered in this study because design requirements at those planets bracket nominally the requirements at Venus, and plans are already underway for a joint Russian-French balloon system at Venus. Viking data has provided quantitative information for definition of specific balloon systems at Mars. Free flying balloons appear capable of providing valuable scientific support for more sophisticated Martian surface probes, but tethered and powered aerostats are not attractive. The Jovian environment is so extreme, hot atmosphere balloons may be the only scientific platforms capable of extended operations there. However, the estimated system mass and thermal energy required are very large.

  19. Ozone profiles from tethered balloon measurements in an urban plume experiment

    NASA Technical Reports Server (NTRS)

    Youngbluth, O., Jr.; Storey, R. W.; Clendenin, C. G.; Jones, S.; Leighty, B.

    1981-01-01

    NASA Langley Research Center used two tethered balloon systems to measure ozone in the general area of Norfolk, Va. The large balloon system which has an altitude range of 1,500 meters was located at Wallops Island, Va., and the smaller balloon which has an altitude range of 900 meters was located at Chesapeake, Va. Each balloon system measured ozone, temperature, humidity, wind speed, and wind direction from ground to its maximum altitude. From these measurements and from the location of the balloon sites, areas of ozone generation and ozone transport may be inferred. The measurements which were taken during August 1979 are discussed as well as the measurement techniques.

  20. Low-Altitude Exploration of the Venus Atmosphere by Balloon

    NASA Technical Reports Server (NTRS)

    Landis, Geoffrey A.

    2010-01-01

    The planet Venus represents an exciting target for future exploration by spacecraft. One target of scientific interest is the lower atmosphere, which represents an environment of high temperature and moderate to high atmospheric pressure. This represents a considerable challenge to the technical art of ballooning, but one which may be amenable to solution. Several possible designs for low-altitude balloons are discussed. Conceptual design for three mission examples are analyzed: a conventional balloon operating below the cloud level at an altitude of 25 kilometers, a large rigid-envelope balloon operating near the surface at an altitude of 5 kilometers, and a small, technology demonstrator rigid-envelope balloon operating at 5 kilometers.

Top