Mechanical Energy and Propulsion in Ergometer Double Poling by Cross-country Skiers.
Danielsen, Jørgen; Sandbakk, Øyvind; Holmberg, Hans-Christer; Ettema, Gertjan
2015-12-01
This study aims to investigate fluctuations in total mechanical energy of the body (Ebody) in relation to external ergometer work (Werg) during the poling and recovery phases of simulated double-poling cross-country skiing. Nine male cross-country skiers (mean ± SD age, 24 ± 5 yr; mean ± SD body mass, 81.7 ± 6.5 kg) performed 4-min submaximal tests at low-intensity, moderate-intensity, and high-intensity levels and a 3-min all-out test on a ski ergometer. Motion capture analysis and load cell recordings were used to measure body kinematics and dynamics. From these, Werg, Ebody (sum of the translational, rotational, and gravitational potential energies of all segments), and their time differentials (power P) were calculated. Ptot--the rate of energy absorption or generation by muscles-tendons--was defined as the sum of Pbody and Perg. Ebody showed large fluctuations over the movement cycle, decreasing during poling and increasing during the recovery phase. The fluctuation in Pbody was almost perfectly out of phase with Perg. Some muscle-tendon energy absorption was observed at the onset of poling. For the rest of poling and throughout the recovery phase, muscles-tendons generated energy to do Werg and to increase Ebody. Approximately 50% of cycle Ptot occurred during recovery for all intensity levels. In double poling, the extensive contribution of the lower extremities and trunk to whole-body muscle-tendon work during recovery facilitates a "direct" transfer of Ebody to Werg during the poling phase. This observation reveals that double poling involves a unique movement pattern different from most other forms of legged terrestrial locomotion, which are characterized primarily by inverted pendulum or spring-mass types of movement.
Bjerkefors, A; Tinmark, F; Nilsson, J; Arndt, A
2013-02-01
This study aimed to evaluate biomechanics during seated double-poling exercises in individuals with spinal cord injury (SCI) and to compare these with those of able-bodied persons (AB). 26 participants volunteered for the study; 13 with SCI (injury levels C7-T12), and 13 AB. A seated double-poling ergometer (SDPE) was developed. 3-dimensional kinematics was measured and piezoelectric force sensors were used to register force in both poles for calculation of power during incremental intensities. Significantly lower power outputs, (143.2 ± 51.1 vs. 198.3 ± 74.9 W) and pole forces (137.1 ± 43.1 vs. 238.2 ± 81.2 N) were observed during maximal effort in SCI compared to AB. Sagittal upper trunk range of motion increased with intensity and ranged from 6.1-34.8° for SCI, and 6.9-31.3° for AB, with larger peak amplitudes in flexion for AB (31.4 ± 12.9°) compared to SCI (10.0 ± 8.0°). All subjects with SCI were able to exercise on the SDPE. Upper body kinematics, power and force outputs increased with intensity in both groups, but were in general, lower in SCI. In conclusion, the SDPE could be successfully used at low to high work intensities enabling both endurance and strength training for individuals with SCI. © Georg Thieme Verlag KG Stuttgart · New York.
Shoulder and Lower Back Joint Reaction Forces in Seated Double Poling.
Lund Ohlsson, Marie; Danvind, Jonas; Holmberg, L Joakim
2018-04-13
Overuse injuries in the shoulders and lower back are hypothesized to be common in cross-country sit-skiing. Athletes with reduced trunk muscle control mainly sits with their knees higher than hips (KH). To reduce spinal flexion, a position with the knees below the hips (KL) was enabled for these athletes using a frontal trunk support. The aim of the study was to compare the shoulder joint (glenohumeral joint) and L4-L5 joint reactions between the sitting positions KL and KH. Five able-bodied female athletes performed submaximal and maximal exercise tests in the sitting positions KL and KH on a ski-ergometer. Measured pole forces and 3-dimensional kinematics served as input for inverse-dynamics simulations to compute the muscle forces and joint reactions in the shoulder and L4-L5 joint. This was the first musculoskeletal simulation study of seated double poling. The results showed that the KH position was favorable for higher performance and decreased values of the shoulder joint reactions for female able-bodied athletes with full trunk control. The KL position was favorable for lower L4-L5 joint reactions and might therefore reduce the risk of lower back injuries. These results indicate that it is hard to optimize both performance and safety in the same sit-ski.
Hegge, Ann Magdalen; Myhre, Kenneth; Welde, Boye; Holmberg, Hans-Christer; Sandbakk, Øyvind
2015-01-01
In the current study, we evaluated the impact of exercise intensity on gender differences in upper-body poling among cross-country skiers, as well as the associated differences in aerobic capacity, maximal strength, body composition, technique and extent of training. Eight male and eight female elite skiers, gender-matched for level of performance by FIS points, carried out a 4-min submaximal, and a 3-min and 30-sec maximal all-out test of isolated upper-body double poling on a Concept2 ski ergometer. Maximal upper-body power and strength (1RM) were determined with a pull-down exercise. In addition, body composition was assessed with a DXA scan and training during the previous six months quantified from diaries. Relative to the corresponding female values (defined as 100%), the power output produced by the men was 88%, 95% and 108% higher during the submaximal, 3-min and 30-sec tests, respectively, and peak power in the pull-down strength exercise was 118% higher (all P<0.001). During the ergometer tests the work performed per cycle by the men was 97%, 102% and 91% greater, respectively, and the men elevated their cycle rate to a greater extent at higher intensities (both P<0.01). Furthermore, men had a 61% higher VO2peak, 58% higher 1RM, relatively larger upper-body mass (61% vs 56%) and reported considerably more upper-body strength and endurance training (all P<0.05). In conclusion, gender differences in upper-body power among cross-country skiers augmented as the intensity of exercise increased. The gender differences observed here are greater than those reported previously for both lower- and whole-body sports and coincided with greater peak aerobic capacity and maximal upper-body strength, relatively more muscle mass in the upper-body, and more extensive training of upper-body strength and endurance among the male skiers.
Hegge, Ann Magdalen; Myhre, Kenneth; Welde, Boye; Holmberg, Hans-Christer; Sandbakk, Øyvind
2015-01-01
In the current study, we evaluated the impact of exercise intensity on gender differences in upper-body poling among cross-country skiers, as well as the associated differences in aerobic capacity, maximal strength, body composition, technique and extent of training. Eight male and eight female elite skiers, gender-matched for level of performance by FIS points, carried out a 4-min submaximal, and a 3-min and 30-sec maximal all-out test of isolated upper-body double poling on a Concept2 ski ergometer. Maximal upper-body power and strength (1RM) were determined with a pull-down exercise. In addition, body composition was assessed with a DXA scan and training during the previous six months quantified from diaries. Relative to the corresponding female values (defined as 100%), the power output produced by the men was 88%, 95% and 108% higher during the submaximal, 3-min and 30-sec tests, respectively, and peak power in the pull-down strength exercise was 118% higher (all P<0.001). During the ergometer tests the work performed per cycle by the men was 97%, 102% and 91% greater, respectively, and the men elevated their cycle rate to a greater extent at higher intensities (both P<0.01). Furthermore, men had a 61% higher VO2peak, 58% higher 1RM, relatively larger upper-body mass (61% vs 56%) and reported considerably more upper-body strength and endurance training (all P<0.05). In conclusion, gender differences in upper-body power among cross-country skiers augmented as the intensity of exercise increased. The gender differences observed here are greater than those reported previously for both lower- and whole-body sports and coincided with greater peak aerobic capacity and maximal upper-body strength, relatively more muscle mass in the upper-body, and more extensive training of upper-body strength and endurance among the male skiers. PMID:26000713
Theoretical analysis of optical poling and frequency doubling effect based on classical model
NASA Astrophysics Data System (ADS)
Feng, Xi; Li, Fuquan; Lin, Aoxiang; Wang, Fang; Chai, Xiangxu; Wang, Zhengping; Zhu, Qihua; Sun, Xun; Zhang, Sen; Sun, Xibo
2018-03-01
Optical poling and frequency doubling effect is one of the effective manners to induce second order nonlinearity and realize frequency doubling in glass materials. The classical model believes that an internal electric field is built in glass when it's exposed by fundamental and frequency-doubled light at the same time, and second order nonlinearity appears as a result of the electric field and the orientation of poles. The process of frequency doubling in glass is quasi phase matched. In this letter, the physical process of poling and doubling process in optical poling and frequency doubling effect is deeply discussed in detail. The magnitude and direction of internal electric field, second order nonlinear coefficient and its components, strength and direction of frequency doubled output signal, quasi phase matched coupled wave equations are given in analytic expression. Model of optical poling and frequency doubling effect which can be quantitatively analyzed are constructed in theory, which set a foundation for intensive study of optical poling and frequency doubling effect.
Wiggen, Øystein N; Waagaard, Silje H; Heidelberg, Cecilie T; Oksa, Juha
2013-12-01
This study compared the effects of cold (-14° C) and moderate environments (6° C) on double poling (DP) sprint performance. Wearing modern cross-country ski racing suits, 14 highly trained male cross-country skiers performed a test protocol on a DP ergometer, consisting of a standardized warm-up followed by a 30-second maximal sprint (DP30s) and a 2-minute maximal sprint (DP2min), and after an 8-minute recovery period, another DP30s and DP2min were performed. Finally, the participants performed an incremental DP test to exhaustion. We observed no difference between rectal temperature in cold and moderate conditions. Mean skin temperature (Tskin) was lower in the cold condition; the lowest values being 20.3° C at -14° C and 27.0° C at 6° C. Power output decreased between the first and the second DP30s under both conditions, but the reduction was 4.9% (p < 0.05) greater in the cold condition. Power output decreased by 4.8% (p < 0.05) between the first and second DP2min at -14° C, but we found no difference at 6° C. In the incremental test to exhaustion, there was a 7.2% (p < 0.05) reduction in peak power output and a 7.8% (p < 0.05) lower peak oxygen consumption at -14° C. In conclusion, this study demonstrated that DP sprint performance was lower at -14° C than at 6° C. Tskin and body temperature were lower at -14° C. This may indicate cooling of superficial musculature and may explain the reduced DP sprint performance observed in our study.
Göpfert, Caroline; Holmberg, Hans-Christer; Stöggl, Thomas; Müller, Erich; Lindinger, Stefan Josef
2013-06-01
Recent developments in cross-country ski racing should promote the use of kick double poling. This technique, however, has not been the focus in athletes' training and has barely been investigated. The aims of the present study were to develop a function-based phase definition and to analyse speed adaptation mechanisms for kick double poling in elite cross-country skiers. Joint kinematics and pole/plantar forces were recorded in 10 athletes while performing kick double poling at three submaximal roller skiing speeds. A speed increase was associated with increases in cycle length and rate, while absolute poling and leg push-off durations shortened. Despite maintained impulses of force, the peak and average pole/leg forces increased. During double poling and leg push-off, ranges of motion of elbow flexion and extension increased (p < 0.05) and were maintained for hip/knee flexion and extension. Cycle length increase was correlated to increases in average poling force (r = 0.71) and arm swing time (r = 0.88; both p < 0.05). The main speed adaptation was achieved by changes in double poling technique; however, leg push-off showed high variability among elite skiers, thus illustrating important aspects for technique training.
A Double-Pole High Voltage High Current Switch
2005-12-01
NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited A DOUBLE- POLE HIGH...December 2005 3. REPORT TYPE AND DATES COVERED Master’s Thesis 4. TITLE AND SUBTITLE: A Double- Pole High Voltage High Current Switch 6. AUTHOR(S...to divert heavy charged particles, e.g. Cu+. 15. NUMBER OF PAGES 68 14. SUBJECT TERMS Double- Pole , Pulse Forming Inductive Network, PFIN
Force interaction and 3D pole movement in double poling.
Stöggl, T; Holmberg, H-C
2011-12-01
The aim of this study was to analyze double poling using combined kinetic and 3D kinematic analysis at high skiing speeds as regards pole force components, pole angles and pole behavior during the poling and swing phase. The hypothesis was that a horizontal pole force is more predictive for maximal skiing speed (V(max)) than the resultant pole force. Sixteen elite skiers performed a double-poling V(max) test while treadmill roller skiing. Pole forces and 3D kinematics of pole movement at a speed of 30 km/h were analyzed and related to V(max). The duration of the "preparation phase" showed the strongest relationship with V(max) (r=0.87, P<0.001). Faster skiers generated longer cycle lengths with longer swing and poling times, had less inclined pole angles at pole plant and a later peak pole force. Horizontal pole forces were not more highly related to V(max) compared with the resultant pole force. Impact force was not related to V(max). At high skiing speeds, skiers should aim to combine high pole forces with appropriate timing of pole forces and appropriate pole and body positions during the swing and poling phase. The emphasis in training should be on the development of specific strength capacities for pole force production and the utilization of these capacities in double-poling training sessions. © 2011 John Wiley & Sons A/S.
NASA Astrophysics Data System (ADS)
Feng, Haike; Zhang, Wei; Zhang, Jie; Chen, Xiaofei
2017-05-01
The perfectly matched layer (PML) is an efficient absorbing technique for numerical wave simulation. The complex frequency-shifted PML (CFS-PML) introduces two additional parameters in the stretching function to make the absorption frequency dependent. This can help to suppress converted evanescent waves from near grazing incident waves, but does not efficiently absorb low-frequency waves below the cut-off frequency. To absorb both the evanescent wave and the low-frequency wave, the double-pole CFS-PML having two poles in the coordinate stretching function was developed in computational electromagnetism. Several studies have investigated the performance of the double-pole CFS-PML for seismic wave simulations in the case of a narrowband seismic wavelet and did not find significant difference comparing to the CFS-PML. Another difficulty to apply the double-pole CFS-PML for real problems is that a practical strategy to set optimal parameter values has not been established. In this work, we study the performance of the double-pole CFS-PML for broad-band seismic wave simulation. We find that when the maximum to minimum frequency ratio is larger than 16, the CFS-PML will either fail to suppress the converted evanescent waves for grazing incident waves, or produce visible low-frequency reflection, depending on the value of α. In contrast, the double-pole CFS-PML can simultaneously suppress the converted evanescent waves and avoid low-frequency reflections with proper parameter values. We analyse the different roles of the double-pole CFS-PML parameters and propose optimal selections of these parameters. Numerical tests show that the double-pole CFS-PML with the optimal parameters can generate satisfactory results for broad-band seismic wave simulations.
Stoggl, Thomas; Enqvist, Jonas; Muller, Erich; Holmberg, Hans-Christer
2010-01-01
In modern sprint cross-country skiing, strength and maximal speed are major determinants of performance. The aims of this study were to ascertain the anthropometric characteristics of world-class sprint skiers and to evaluate whether a specific body composition and/or body dimension characterizes a successful sprint skier. Our hypothesis was that body height and lean body mass are related to peak speed in double poling and diagonal stride. Fourteen male national and international elite skiers performed two peak speed tests in double poling and diagonal stride roller skiing on a treadmill and were analysed using dual-energy X-ray absorptiometry to determine body composition and body dimensions. Relative pole length was positively correlated with both techniques (double poling: r = 0.77, P < 0.01; diagonal stride: r = 0.60, P < 0.05) and was the only variable that was part of the multiple regression model for both double poling and diagonal stride peak speed. Body height was not correlated with any technique, whereas lean trunk mass (r = 0.75, P < 0.01), body mass index (r = 0.66, P < 0.01), total lean mass (r = 0.69, P < 0.01), and body mass (r = 0.57, P < 0.05) were positively related to double poling peak speed. Total lean mass (absolute: r = 0.58, P < 0.05; relative: r = 0.76, P < 0.001) and relative lean mass of the trunk, arms (both r = 0.72, P < 0.01), and legs (r = 0.54, P < 0.05) were positively related to diagonal stride peak speed. In conclusion, skiers should aim to achieve a body composition with a high percentage of lean mass and low fat mass. A focus on trunk mass through increased muscle mass appears to be important, especially for double poling. The use of longer poles (percent body height) seems to be advantageous for both double poling and diagonal stride peak speed, whereas body dimensions do not appear to be a predictive factor.
NASA Astrophysics Data System (ADS)
Vorhaus, J. L.; Fabian, W.; Ng, P. B.; Tajima, Y.
1981-02-01
A set of multi-pole, multi-throw switch devices consisting of dual-gate GaAs FET's is described. Included are single-pole, single-throw (SPST), double-pole, double-throw (DPDT), and single-pole four-throw (SP4T) switches. Device fabrication and measurement techniques are discussed. The device models for these switches were based on an equivalent circuit of a dual-gate FET. The devices were found to have substantial gain in X-band and low Ku-band.
Stress Studies at Kennedy Space Center: a Backward and Forward Look
NASA Technical Reports Server (NTRS)
Decker, A. I.
1971-01-01
Possible relationships between occupational and other stresses on ischemic heart disease are explored. Three procedures were used: (1) double master 2-step test, (2) dynamic ECG technique using avionics equipment, and (3) submaximal stress testing with Marco bicycle ergometer.
Pole lengths influence O2-cost during double poling in highly trained cross-country skiers.
Carlsen, Camilla Høivik; Rud, Bjarne; Myklebust, Håvard; Losnegard, Thomas
2018-02-01
In elite cross-country skiing, double poling is used in different terrain. This study compared O 2 -cost and kinematics during double poling with four different pole lengths [self-selected (SS), SS - 5 cm, SS + 5 cm, SS + 10 cm] at Low versus Moderate incline. Thirteen highly trained male cross-country skiers (mean ± SD 23 ± 3 years; 182 ± 4 cm; 77 ± 6 kg) completed eight submaximal trials with roller skis on a treadmill at two conditions: "Low incline" (1.7°; 4.5 m s -1 ) and "Moderate incline" (4.5°; 2.5 m s -1 ) with each of the four pole lengths. O 2 -cost and 3D body kinematics were assessed in each trial. In Low incline, SS + 10 cm induced a lower O 2 -cost than all the other pole lengths [P < 0.05; effect size (ES) 0.5-0.8], whereas no differences were found between the remaining pole lengths (P > 0.05; ES 0.2-0.4). In Moderate incline, significant differences between all pole lengths were found for O 2 -cost, with SS - 5 cm > SS > SS + 5 cm > SS + 10 cm (P < 0.05; ES 0.6-1.8). The relative differences in O 2 -cost between SS and the other pole lengths were greater in Moderate incline than Low incline (SS - 5 cm; 1.5%, ES 0.8, SS + 5 cm; 1.3%, ES 1.0, and SS + 10 cm; 1.9%, ES 1.0, all P < 0.05). No difference was found in cycle, poling or reposition times between pole lengths. However, at both conditions a smaller total vertical displacement of center of mass was observed with SS + 10 cm compared to the other pole lengths. Increasing pole length from SS - 5 cm to SS + 10 cm during double poling induced lower O 2 -cost and this advantage was greater in Moderate compared to Low incline.
Vandbakk, Kristine; Welde, Boye; Kruken, Andrea Hovstein; Baumgart, Julia; Ettema, Gertjan; Karlsen, Trine; Sandbakk, Øyvind
2017-01-01
This study compared the effects of adding upper-body sprint-intervals or continuous double poling endurance training to the normal training on maximal upper-body strength and endurance capacity in female cross-country skiers. In total, 17 female skiers (age: 18.1±0.8yr, body mass: 60±7 kg, maximal oxygen uptake (VO2max): 3.30±0.37 L.min-1) performed an 8-week training intervention. Here, either two weekly sessions of six to eight 30-s maximal upper-body double poling sprint-intervals (SIG, n = 8) or 45–75 min of continuous low-to-moderate intensity double poling on roller skis (CG, n = 9) were added to their training. Before and after the intervention, the participants were tested for physiological and kinematical responses during submaximal and maximal diagonal and double poling treadmill roller skiing. Additionally, we measured maximal upper-body strength (1RM) and average power at 40% 1RM in a poling-specific strength exercise. SIG improved absolute VO2max in diagonal skiing more than CG (8% vs 2%, p<0.05), and showed a tendency towards higher body-mass normalized VO2max (7% vs 2%, p = 0.07). Both groups had an overall improvement in double poling peak oxygen uptake (10% vs 6% for SIG and CG) (both p<0.01), but no group-difference was observed. SIG improved 1RM strength more than CG (18% vs 10%, p<0.05), while there was a tendency for difference in average power at 40% 1RM (20% vs 14%, p = 0.06). Oxygen cost and kinematics (cycle length and rate) in double poling and diagonal remained unchanged in both groups. In conclusion, our study demonstrates that adding upper-body sprint-interval training is more effective than continuous endurance training in improving upper-body maximal strength and VO2max. PMID:28241030
Maestre, H; Torregrosa, A J; Fernández-Pousa, C R; Rico, M L; Capmany, J
2008-05-01
We report a dual-wavelength continuous-wave laser at 542.4 and 546.8 nm based on an Nd(3+)-doped aperiodically poled lithium niobate crystal. Two fundamental infrared (IR) wavelengths at 1084.8 and 1093.6 nm are simultaneously oscillated and self-frequency-doubled to green. The aperiodic domain distribution patterned in the crystal allows for quasi-phase matched self-frequency-doubling of both IR fundamentals while avoiding their sum-frequency mixing.
Baek, Minki; Au, Jason; Huang, Gene O; Koh, Chester J
2017-04-01
We describe our experience with robot-assisted laparoscopic (RAL) pyeloureterostomy in infants with duplex systems and upper pole hydronephrosis with an emphasis on the various double J (DJ) ureteral stent placement techniques. We used our RAL pyeloureterostomy technique in two female infants with duplex systems and upper pole hydronephrosis. For case 1, we introduced the DJ stent and placed it in the recipient lower pole ureter during the robotic operation in an antegrade fashion. For case 2, we inserted the DJ stent during retrograde pyelography prior to the robotic procedure in a retrograde fashion, and the proximal portion of the stent was placed across the anastomosis into the upper pole renal pelvis. Postoperatively, each of the patients were discharged on postoperative day 1 without complications. The postoperative renal ultrasound at 3 months demonstrated marked improvement of the right upper pole hydronephrosis in both patients. RAL pyeloureterostomy represents a minimally invasive option for upper tract reconstruction of duplex systems with upper pole hydronephrosis in infants. The DJ stent can be placed at the beginning or during the procedure. The stent can be placed in the lower pole ureter or across the anastomosis into the upper pole renal pelvis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Double-push skating versus V2 and V1 skating on uphill terrain in cross-country skiing.
Stöggl, Thomas; Kampel, Wolfgang; Müller, Erich; Lindinger, Stefan
2010-01-01
The aims of the study were a) to compare the double-push skating technique with the V2 and the V1 skating techniques on an uphill terrain by a kinematic and kinetic analysis, b) to provide kinetic and kinematic data of the V1 technique at maximal skiing speeds, and c) to test the hypotheses that the double-push skating technique is faster compared with the V2 and the V1 skating techniques. Six elite skiers performed maximum speed sprints over a 60-m uphill section (7 degrees -10 degrees) using the double-push, the V2, and the V1 techniques. Pole and plantar forces and cycle characteristics were analyzed. The double-push skating technique was approximately 4.3% faster (P < 0.05) compared with the V2 skating technique and equally fast compared with the V1 skating technique. The double-push and the V2 techniques demonstrated longer cycle lengths, lower cycle rates (both P < 0.05), and equal poling frequencies and pole forces compared with the V1 technique. Cycle length, peak foot force, and knee extension ranges of motion and velocities were higher in the double-push technique compared with the V2 technique (all P values <0.05). Center of pressure was located more laterally in the double-push technique compared with the other two techniques (P < 0.05). All measured skiing speeds were drastically higher compared with former studies. The higher skiing speeds of the V1 and the double-push techniques compared with the V2 technique stress the mechanical advantage of those techniques on uphill terrain. Because of larger cycle lengths, lower cycle rate, longer recovery times, and equal poling frequency, the double-push technique might be seen as more economic on steep uphills compared with the V1 technique. From a tactical point of view compared with the V1 technique, the double-push technique needs less space due to less lateral displacement, and no technique transitions are necessary when entering and leaving an uphill section.
Control of speed during the double poling technique performed by elite cross-country skiers.
Lindinger, Stefan Josef; Stöggl, Thomas; Müller, Erich; Holmberg, Hans-Christer
2009-01-01
Double poling (DP) as a main technique in cross-country skiing has developed substantially over the last 15 yr. The purpose of the present study was to analyze the question, "How do modern elite skiers control DP speed?" Twelve male elite cross-country skiers roller skied using DP at 9, 15, 21, and 27 km.h(-1) and maximum velocity (V(max)). Cycle characteristics, pole and plantar forces, and elbow, hip, and knee joint angles were analyzed. Both poling frequency and cycle length increased up to 27 km.h (-1)(P < 0.05), with a further increase in poling frequency at V(max) (P < 0.05). Peak pole force, rate of force development, and rearfoot plantar force increased with submaximal velocities (V(sm)), whereas poling time and time-to-peak pole force gradually shortened (P < 0.05). Changes in elbow joint kinematics during the poling phase were characterized by a decreased angle minimum and an increased flexion and extension ranges of motion as well as angular velocities across V(sm) (P < 0.05), with no further changes at V(max). Hip and knee joint kinematics adapted across V(sm) by 1) decreasing angles at pole plant and angle minima during the poling phase, 2) increasing the ranges of motion and angular velocities during the flexion phases occurring around pole plant, and 3) increasing extension ranges of motion and angular velocities during the recovery phase (all P values <0.05), with no further changes at V(max). Elite skiers control DP speed by increasing both poling frequency and cycle length; the latter is achieved by increased pole force despite reduced poling time. Adaptation to higher speeds was assisted by an increased range of motion, smaller angle minima, and higher angular velocities in the elbow, the hip, and the knee joints.
Exercise economy in skiing and running
Losnegard, Thomas; Schäfer, Daniela; Hallén, Jostein
2014-01-01
Substantial inter-individual variations in exercise economy exist even in highly trained endurance athletes. The variation is believed to be determined partly by intrinsic factors. Therefore, in the present study, we compared exercise economy in V2-skating, double poling, and uphill running. Ten highly trained male cross-country skiers (23 ± 3 years, 180 ± 6 cm, 75 ± 8 kg, VO2peak running: 76.3 ± 5.6 mL·kg−1·min−1) participated in the study. Exercise economy and VO2peak during treadmill running, ski skating (V2 technique) and double poling were compared based on correlation analysis. There was a very large correlation in exercise economy between V2-skating and double poling (r = 0.81) and large correlations between V2-skating and running (r = 0.53) and double poling and running (r = 0.58). There were trivial to moderate correlations between exercise economy and the intrinsic factors VO2peak (r = 0.00–0.23), cycle rate (r = 0.03–0.46), body mass (r = −0.09–0.46) and body height (r = 0.11–0.36). In conclusion, the inter-individual variation in exercise economy could be explained only moderately by differences in VO2peak, body mass and body height. Apparently other intrinsic factors contribute to the variation in exercise economy between highly trained subjects. PMID:24478718
Stöggl, Roland; Müller, Erich; Stöggl, Thomas
2017-01-01
The aims of the current study were to analyze whether specific roller skiing tests and cycle length are determinants of youth cross-country (XC) skiing performance, and to evaluate sex specific differences by applying non-invasive diagnostics. Forty-nine young XC skiers (33 boys; 13.8 ± 0.6 yrs and 16 girls; 13.4 ± 0.9 yrs) performed roller skiing tests consisting of both shorter (50 m) and longer durations (575 m). Test results were correlated with on snow XC skiing performance (PXC) based on 3 skating and 3 classical distance competitions (3 to 6 km). The main findings of the current study were: 1) Anthropometrics and maturity status were related to boys’, but not to girls’ PXC; 2) Significant moderate to acceptable correlations between girls’ and boys’ short duration maximal roller skiing speed (double poling, V2 skating, leg skating) and PXC were found; 3) Boys’ PXC was best predicted by double poling test performance on flat and uphill, while girls’ performance was mainly predicted by uphill double poling test performance; 4) When controlling for maturity offset, boys’ PXC was still highly associated with the roller skiing tests. The use of simple non-invasive roller skiing tests for determination of PXC represents practicable support for ski clubs, schools or skiing federations in the guidance and evaluation of young talent. Key points Double poling tests on flat and uphill terrain and short duration maximal speed tests were the highest cross-country skiing predicting factors in girls and boys. Only in the boys there was an effect of maturation on the performance outcomes, pointing out that girls seem to be almost fully matured at the age of 13 in contrast to the boys. Roller skiing tests over short distance (50-m) and longer distance 225 m and 350 m are stable and valid measures and suitable for performance prediction in youth cross-country skiers. PMID:28912656
Restraint system for ergometer
NASA Technical Reports Server (NTRS)
Gause, R. L.; Spier, R. A. (Inventor)
1973-01-01
A restraint system for securing a person to an ergometer while exercising under zero gravity conditions or while operating the ergometer in earth environment in a position other than the upright position. A padded, form-fitting body belt fits around the operator's waist and suspenders are attached to the body belt. The body belt is secured to the ergometer forwardly and rearwardly of the ergometer seat by adjustable belts joined to the body belt and releasably hooked to the ergometer frame.
Jäckle, H; Kalthoff, K
1980-01-01
In embryos of the chironomid midge Smittia, synthesis of a posterior indicator protein designated PI1 (Mr approximately 50,000; pI approximately 5.5) forecasts development of an abdomen as opposed to head and thorax. The protein is synthesized several hours before germ anlage formation. In normal embryos at early blastoderm stages, synthesis of PI1 is restricted to posterior embryonic fragments but not to pole cells. In "double-abdomen" embryos, a mirror-image duplication of the abdomen is formed by cells that would otherwise develop into head and thorax. Embryos were programmed for double-abdomen development by UV irradiation of the anterior pole, and half of them were reprogrammed for normal development by subsequent exposure to visible light (photoreversal). Correspondingly, PI1 was synthesized in anterior fragments of UV-irradiated embryos but not after photoreversal. In a control experiment, UV irradiation of the posterior pole caused neither double-abdomen formation nor PI1 synthesis in anterior fragments. The identity of PI1 formed in anterior fragments of prospective double abdomens with the protein found in posterior fragments was revealed by two-dimensional gel electrophoresis and limited proteolysis. Suppression of PI1 synthesis in anterior fragments of normal embryos is ascribed to the activity of cytoplasmic ribonucleoprotein particles thought to act as anterior determinants. Images PMID:6935679
Gioacchini, Matteo; Bottoni, Manuela; Grassetti, Luca; Scalise, Alessandro
2015-01-01
Summary: Lower-pole shaping of the breast is sometimes a difficult challenge when performing vertical mammoplasty. The problems mostly encountered are too large breast bases, persistent dog ears, which require long incision, and poor breast projection. We report a modification of the technique that we use in breast reduction so as to better shape the lower pole and to reduce revision surgery. PMID:26034653
NASA Astrophysics Data System (ADS)
Azhari, Afreen; Kuwano, Yuki; Xiao, Xia; Kikkawa, Takamaro
2018-01-01
A 3-20 GHz transmit/receive (T/R) double-pole-16-throw (DP16T) switching matrix has been developed on a printed circuit board (PCB) to control sixteen antennas in a radar-based portable breast-cancer detection system. The DP16T switch consists of four 65 nm CMOS 0.01-20 GHz double-pole-four-throw (DP4T) switches. The proposed switch increase the number of T/R combinations to 224 from the 196 of a conventional switching matrix in order to construct high-resolution images. Using this switch and a 4 × 4 slot antenna array, a 10 × 10 mm2 aluminum target was detected with an 8-GHz-center-frequency Gaussian monocycle pulse. The power consumption of the switch is only 1.2 mW. To the best of the authors’ knowledge, this is the first T/R radio frequency (RF) DP16T switching matrix, which was realized with four CMOS DP4T switches on a PCB and was measured with RF PCB connectors.
Sandbakk, Øyvind; Leirdal, Stig; Ettema, Gertjan
2015-03-01
The current study compared differences in cycle characteristics, energy expenditure and peak speed between double poling (DP) and G3 skating. Eight world class male sprint skiers performed a 5-min submaximal test at 16 km h(-1) and an incremental test to exhaustion at a 5% incline during treadmill roller skiing with two different techniques: DP where all propulsion comes from poling, and G3 skating where leg skating is added to each double poling movement. Video analyses determined cycle characteristics; respiratory parameters and blood lactate concentration determined the physiological responses. G3 skating resulted in 16% longer cycle lengths at 16% lower cycle rates, whereas oxygen uptake was independent of technique during submaximal roller skiing. The corresponding advantages for G3 skating during maximal roller skiing were reflected in 14% higher speed, 30% longer cycle length at 16% lower cycle rate and 11% higher peak oxygen uptake (all p < 0.05). Compared to DP approximately 14% higher speed was achieved when leg push-offs were added in G3 skating. This was done by major increases in cycle lengths at slightly lower cycle rates and a higher aerobic energy delivery. However, the oxygen uptake for a given submaximal speed was not affected by technique although higher cycle rate was used in DP.
Shing, Cecilia M; Webb, Jessica J; Driller, Matthew W; Williams, Andrew D; Fell, James W
2013-08-01
Adiponectin influences metabolic adaptations that would prove beneficial to endurance athletes, and yet to date there is little known about the response of adiponectin concentrations to exercise, and, in particular, the response of this hormone to training in an athlete population. This study aimed to determine the response of plasma adiponectin concentrations to acute exercise after 2 different training programs and to determine the influence of the training on body composition. Seven state-level representative rowers (age: 19 ± 1.2 years [mean ± SD], height: 1.77 ± 0.10 m, body mass: 74.0 ± 10.7 kg, VO2peak 62.1 ± 7.0 ml·kg·min) participated in the double-blind, randomized crossover investigation. Rowers performed an incremental graded exercise test before and after completing 4 weeks of high-intensity interval ergometer training and 4 weeks of traditional ergometer rowing training. Rowers' body composition was assessed at baseline and after each training program. Significant increases in plasma adiponectin concentration occurred in response to maximal exercise after completion of the high-intensity interval training (p = 0.016) but not after traditional ergometer rowing training (p = 0.69). The high-intensity interval training also resulted in significant increases in mean 4-minute power output (p = 0.002) and VO2peak (p = 0.05), and a decrease in body fat percentage (p = 0.022). Mean 4-minute power output, VO2peak, and body fat percentage were not significantly different after 4 weeks of traditional ergometer rowing training (p > 0.05). Four weeks of high-intensity interval training is associated with an increase in adiponectin concentration in response to maximal exercise and a reduction in body fat percentage. The potential for changes in adiponectin concentration to reflect positive training adaptations and athlete performance level should be further explored.
Balmer, Nigel; Pleasence, Pascoe; Nevill, Alan
2012-01-01
A number of studies have pointed to a plateauing of athletic performance, with the suggestion that further improvements will need to be driven by revolutions in technology or technique. In the present study, we examine post-war men's Olympic performance in jumping events (pole vault, long jump, high jump, triple jump) to determine whether performance has indeed plateaued and to present techniques, derived from models of human growth, for assessing the impact of technological and technical innovation over time (logistic and double logistic models of growth). Significantly, two of the events involve well-documented changes in technology (pole material in pole vault) or technique (the Fosbury Flop in high jump), while the other two do not. We find that in all four cases, performance appears to have plateaued and that no further "general" improvement should be expected. In the case of high jump, the double logistic model provides a convenient method for modelling and quantifying a performance intervention (in this case the Fosbury Flop). However, some shortcomings are revealed for pole vault, where evolutionary post-war improvements and innovation (fibre glass poles) were concurrent, preventing their separate identification in the model. In all four events, it is argued that further general growth in performance will indeed need to rely predominantly on technological or technical innovation.
Repeatability and Validity of the Combined Arm-Leg (Cruiser) Ergometer
ERIC Educational Resources Information Center
Simmelink, Elisabeth K.; Wempe, Johan B.; Geertzen, Jan H. B.; Dekker, Rienk
2009-01-01
The measurement of physical fitness of lower limb amputees is difficult, as the commonly used ergometer tests have limitations. A combined arm-leg (Cruiser) ergometer might be valuable. The aim of this study was to establish the repeatability and validity of the combined arm-leg (Cruiser) ergometer. Thirty healthy volunteers carried out three…
Design of permanent magnet eddy current brake for a small scaled electromagnetic launch model
NASA Astrophysics Data System (ADS)
Zhou, Shigui; Yu, Haitao; Hu, Minqiang; Huang, Lei
2012-04-01
A variable pole-pitch double-sided permanent magnet (PM) linear eddy current brake (LECB) is proposed for a small scaled electromagnetic launch model. A two-dimensional (2D) analytical steady state model is presented for the double-sided PM-LECB, and the expression for the braking force is derived. Based on the analytical model, the material and eddy current skin effect of the conducting plate are analyzed. Moreover, a variable pole-pitch double-sided PM-LECB is proposed for the effective braking of the moving plate. In addition, the braking force is predicted by finite element (FE) analysis, and the simulated results are in good agreement with the analytical model. Finally, a prototype is presented to test the braking profile for validation of the proposed design.
Mays, Ryan J.; Boér, Nicholas F.; Mealey, Lisa M.; Kim, Kevin H.; Goss, Fredric L.
2015-01-01
This investigation compared estimated and predicted peak oxygen consumption (VO2peak) and maximal heart rate (HRmax) among the treadmill, cycle ergometer and elliptical ergometer. Seventeen women (mean ± SE: 21.9 ± .3 yrs) exercised to exhaustion on all modalities. ACSM metabolic equations were used to estimate VO2peak. Digital displays on the elliptical ergometer were used to estimate VO2peak. Two individual linear regression methods were used to predict VO2peak: 1) two steady state heart rate (HR) responses up to 85% of age-predicted HRmax, and 2) multiple steady state/non-steady state HR responses up to 85% of age-predicted HRmax. Estimated VO2peak for the treadmill (46.3 ± 1.3 ml · kg−1 · min−1) and the elliptical ergometer (44.4 ± 1.0 ml · kg−1 · min−1) did not differ. The cycle ergometer estimated VO2peak (36.5 ± 1.0 ml · kg−1 · min−1) was lower (p < .001) than the estimated VO2peak values for the treadmill and elliptical ergometer. Elliptical ergometer VO2peak predicted from steady state (51.4 ± .8 ml · kg−1 · min−1) and steady state/non-steady state (50.3 ± 2.0 ml · kg−1 · min−1) models were higher than estimated elliptical ergometer VO2peak, p < .01. HRmax and estimates of VO2peak were similar between the treadmill and elliptical ergometer, thus cross-modal exercise prescriptions may be generated. The use of digital display estimates of submaximal oxygen uptake for the elliptical ergometer may not be an accurate method for predicting VO2peak. Health-fitness professionals should use caution when utilizing submaximal elliptical ergometer digital display estimates to predict VO2peak. PMID:20393357
Construction of an isokinetic eccentric cycle ergometer for research and training.
Elmer, Steven J; Martin, James C
2013-08-01
Eccentric cycling serves a useful exercise modality in clinical, research, and sport training settings. However, several constraints can make it difficult to use commercially available eccentric cycle ergometers. In this technical note, we describe the process by which we built an isokinetic eccentric cycle ergometer using exercise equipment modified with commonly available industrial parts. Specifically, we started with a used recumbent cycle ergometer and removed all the original parts leaving only the frame and seat. A 2.2 kW electric motor was attached to a transmission system that was then joined with the ergometer. The motor was controlled using a variable frequency drive, which allowed for control of a wide range of pedaling rates. The ergometer was also equipped with a power measurement device that quantified work, power, and pedaling rate and provided feedback to the individual performing the exercise. With these parts along with some custom fabrication, we were able to construct an isokinetic eccentric cycle ergometer suitable for research and training. This paper offers a guide for those individuals who plan to use eccentric cycle ergometry as an exercise modality and wish to construct their own ergometer.
de Campos Mello, Fernando; de Moraes Bertuzzi, Rômulo Cássio; Grangeiro, Patricia Moreno; Franchini, Emerson
2009-11-01
This study investigated the energy system contributions of rowers in three different conditions: rowing on an ergometer without and with the slide and rowing in the water. For this purpose, eight rowers were submitted to 2,000 m race simulations in each of the situations defined above. The fractions of the aerobic (W (AER)), anaerobic alactic (W (PCR)) and anaerobic lactic (W ([La-])) systems were calculated based on the oxygen uptake, the fast component of excess post-exercise oxygen uptake and changes in net blood lactate, respectively. In the water, the metabolic work was significantly higher [(851 (82) kJ] than during both ergometer [674 (60) kJ] and ergometer with slide [663 (65) kJ] (P < or = 0.05). The time in the water [515 (11) s] was higher (P < 0.001) than in the ergometers with [398 (10) s] and without the slide [402 (15) s], resulting in no difference when relative energy expenditure was considered: in the water [99 (9) kJ min(-1)], ergometer without the slide [99.6 (9) kJ min(-1)] and ergometer with the slide [100.2 (9.6) kJ min(-1)]. The respective contributions of the W (AER), W (PCR) and W ([La-]) systems were water = 87 (2), 7 (2) and 6 (2)%, ergometer = 84 (2), 7 (2) and 9 (2)%, and ergometer with the slide = 84 (2), 7 (2) and 9 (1)%. VO2, HR and lactate were not different among conditions. These results seem to indicate that the ergometer braking system simulates conditions of a bigger and faster boat and not a single scull. Probably, a 2,500 m test should be used to properly simulate in the water single-scull race.
Solid-state switch increases switching speed
NASA Technical Reports Server (NTRS)
Mcgowan, G. F.
1966-01-01
Solid state switch for commutating capacitors in an RC commutated network increases switching speed and extends the filtering or commutating frequency spectrum well into the kilocycle region. The switch is equivalent to the standard double- pole double-throw /DPDT/ relay and is driven from digital micrologic circuits.
Crown Release Promotes Faster Diameter Growth of Pole-Size Black Walnut
Robert E. Phares; Robert D. Williams
1971-01-01
Complete crown release more than doubles the diameter growth of pole-size black walnut trees in southern Indiana over a 10-year period. Partially released trees gew about 50 percent more than unreleased trees. The faster growth of the released trees was directly related to increases in crown-area expansion. Most of the study trees produced bole sprouts; however, the...
NASA Technical Reports Server (NTRS)
Bynum, B. G.; Gause, R. L.; Spier, R. A.
1971-01-01
System overcomes previous ergometer design and calibration problems including inaccurate measurements, large weight, size, and input power requirements, poor heat dissipation, high flammability, and inaccurate calibration. Device consists of lightweight, accurately controlled ergometer, restraint system, and calibration system.
Tilting table for ergometer and for other biomedical devices
NASA Technical Reports Server (NTRS)
Gause, R. L.; Spier, R. A. (Inventor)
1973-01-01
The apparatus is for testing the human body in a variety of positions, ranging from the vertical to the supine, while exercising on an ergometer; and can also be used for angular positioning of other biomedical devices. It includes a floor plate and a hinged plate upon which to fix the ergometer, a back rest and a head rest attached at right angles to said hinged plate and behind the seat of the ergometer, dual hydraulic cylinders for raising and lowering the hinged plate through 90 deg by means of a self contained hydraulic system, with valve means for control and positive stops on the apparatus to prevent over travel. Tests can be made with the subject positioned on the seat of the ergometer, through the various angles, with a substantially normal body attitude relative to the seat and ergometer.
The effects of salmeterol on power output in nonasthmatic athletes.
McDowell, S L; Fleck, S J; Storms, W W
1997-04-01
Salmeterol xinafoate is a new aerosol inhalant that is used in the treatment of asthma. It is currently banned by the International Olympic Committee because of the concern that it may lend an unfair competitive advantage to the user. The purpose of this study was to determine whether salmeterol improves short-term anaerobic performance in elite nonasthmatic track cyclists. Eleven elite track cyclists volunteered to perform a 30-second all-out cycle ergometer test 3 hours after receiving either 42 micrograms of salmeterol xinafoate or placebo applied in a double-blind crossover procedure. During the ergometer test, peak power output, total work, time to peak power, and percent fatigue (decline in power output) were measured. Pulmonary measurements were also taken before and at various time points after inhalation and the ergometer test. A methacholine challenge was administered to each subject before participation in the study to ensure that none of the subjects had any reactive airway diseases. There were no significant differences (p > 0.05) between the placebo and salmeterol trials for peak power output, total work performed during the 30-second test, percent fatigue, and time to peak power. No differences between trials were observed for the pulmonary function test variables at any of the time points. Blood lactate concentrations before and after administration of drug or placebo were also not significantly different between trials. Additionally, salmeterol did not affect the maximal heart rate achieved during the test as compared with the placebo. Short-term salmeterol use within the prescribed dosage was not shown to increase short-term power output in nonasthmatic cyclists.
Anaerobic Threshold and Salivary α-amylase during Incremental Exercise.
Akizuki, Kazunori; Yazaki, Syouichirou; Echizenya, Yuki; Ohashi, Yukari
2014-07-01
[Purpose] The purpose of this study was to clarify the validity of salivary α-amylase as a method of quickly estimating anaerobic threshold and to establish the relationship between salivary α-amylase and double-product breakpoint in order to create a way to adjust exercise intensity to a safe and effective range. [Subjects and Methods] Eleven healthy young adults performed an incremental exercise test using a cycle ergometer. During the incremental exercise test, oxygen consumption, carbon dioxide production, and ventilatory equivalent were measured using a breath-by-breath gas analyzer. Systolic blood pressure and heart rate were measured to calculate the double product, from which double-product breakpoint was determined. Salivary α-amylase was measured to calculate the salivary threshold. [Results] One-way ANOVA revealed no significant differences among workloads at the anaerobic threshold, double-product breakpoint, and salivary threshold. Significant correlations were found between anaerobic threshold and salivary threshold and between anaerobic threshold and double-product breakpoint. [Conclusion] As a method for estimating anaerobic threshold, salivary threshold was as good as or better than determination of double-product breakpoint because the correlation between anaerobic threshold and salivary threshold was higher than the correlation between anaerobic threshold and double-product breakpoint. Therefore, salivary threshold is a useful index of anaerobic threshold during an incremental workload.
Wheelchair ergometer. Development of a prototype with electronic braking.
Forchheimer, F; Lundberg, A
1986-01-01
A new wheelchair ergometer is described, which compensates for the pulsating character of the work by an automatic control system. This makes it possible to maintain a constant level of power during wheelchair work. An automatic control system has been integrated in an electronically braked bicycle ergometer, and a pedal unit from Rodby Electronic bicycle ergometer RE 820 has been coupled to a modified test wheelchair. With this device, the physical working capacity during submaximal circumstances can be tested in handicapped persons.
Fin-line PIN-diode attenuators and switches for 94 GHz range
NASA Astrophysics Data System (ADS)
Meinel, H.; Callsen, H.
1982-06-01
The letter reports new results of fin-line PIN-diode attenuators and switches for the 94 GHz range. Design and performance of SPST and SPDT switches - single pole single throw and single pole double throw, respectively - will be presented. The attenuation of the SPST switch, for example, can be adjusted between 2 and 35 dB over the entire waveguide band from 75 to 110 GHz.
Reliability and effect of sodium bicarbonate: buffering and 2000-m rowing performance.
Carr, Amelia J; Slater, Gary J; Gore, Christopher J; Dawson, Brian; Burke, Louise M
2012-06-01
The aim of this study was to determine the effect and reliability of acute and chronic sodium bicarbonate ingestion for 2000-m rowing ergometer performance (watts) and blood bicarbonate concentration [HCO3-]. In a crossover study, 7 well-trained rowers performed paired 2000-m rowing ergometer trials under 3 double-blinded conditions: (1) 0.3 grams per kilogram of body mass (g/kg BM) acute bicarbonate; (2) 0.5 g/kg BM daily chronic bicarbonate for 3 d; and (3) calcium carbonate placebo, in semi-counterbalanced order. For 2000-m performance and [HCO3-], we examined differences in effects between conditions via pairwise comparisons, with differences interpreted in relation to the likelihood of exceeding smallest worthwhile change thresholds for each variable. We also calculated the within-subject variation (percent typical error). There were only trivial differences in 2000-m performance between placebo (277 ± 60 W), acute bicarbonate (280 ± 65 W) and chronic bicarbonate (282 ± 65 W); however, [HCO3-] was substantially greater after acute bicarbonate, than with chronic loading and placebo. Typical error for 2000-m mean power was 2.1% (90% confidence interval 1.4 to 4.0%) for acute bicarbonate, 3.6% (2.5 to 7.0%) for chronic bicarbonate, and 1.6% (1.1 to 3.0%) for placebo. Postsupplementation [HCO3-] typical error was 7.3% (5.0 to 14.5%) for acute bicarbonate, 2.9% (2.0 to 5.7%) for chronic bicarbonate and 6.0% (1.4 to 11.9%) for placebo. Performance in 2000-m rowing ergometer trials may not substantially improve after acute or chronic bicarbonate loading. However, performances will be reliable with both acute and chronic bicarbonate loading protocols.
Derbyshire, Brian; Raut, Videshnandan V.
2013-01-01
Historically, wire markers were attached to cemented all-plastic acetabular cups to demarcate the periphery and to measure socket wear. The wire shape was either a semi-circle passing over the pole of the cup, or a circle around the cup equator. More recently, “double-D” shaped markers were introduced with a part-circular aspect passing over the pole and a semi-circular aspect parallel to the equatorial plane. This configuration enabled cup retroversion to be distinguished from anteversion. In this study, the accuracy of radiographic measurement of cup orientation and wear was assessed for cups with “double-D” and circular markers. Each cup was attached to a measurement jig which could vary the anteversion/retroversion and internal/external rotation of the cup. A metal femoral head was fixed within the socket and radiographic images were created for all combinations of cup orientation settings. The images were measured using software with automatic edge detection, and cup orientation and zero-wear accuracies were determined for each setting. The median error for cup version measurements was similar for both types of wire marker (0.2° double-D marker, −0.24° circular marker), but measurements of the circular marker were more repeatable. The median inclination errors were 2.05° (double-D marker) and 0.23° (circular marker). The median overall “zero wear” errors were 0.19 mm (double-D marker) and 0.03 mm (circular marker). Measurements of the circular wire marker were much more repeatable. PMID:23813165
Designing a Double-Pole Nanoscale Relay Based on a Carbon Nanotube: A Theoretical Study
NASA Astrophysics Data System (ADS)
Mu, Weihua; Ou-Yang, Zhong-can; Dresselhaus, Mildred S.
2017-08-01
We theoretically investigate a novel and powerful double-pole nanoscale relay based on a carbon nanotube, which is one of the nanoelectromechanical switches being able to work under the strong nuclear radiation, and analyze the physical mechanism of the operating stages in the operation, including "pull in," "connection," and "pull back," as well as the key factors influencing the efficiency of the devices. We explicitly provide the analytical expression of the two important operation voltages, Vpull in and Vpull back , therefore clearly showing the dependence of the material properties and geometry of the present devices by the analytical method from basic physics, avoiding complex numerical calculations. Our method is easy to use in preparing the design guide for fabricating the present device and other nanoelectromechanical devices.
Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer
NASA Technical Reports Server (NTRS)
Montes, Oliver; Dawson, Douglas E.; Kangaslahti, Pekka P.
2012-01-01
In order to reduce the effect of gain and noise instabilities in the RF chain of a microwave radiometer, a Dicke radiometer topology is often used, as in the case of the proposed surface water and ocean topography (SWOT) radiometer instrument. For this topology, a single-pole double-throw (SPDT) microwave switch is needed, which must have low insertion loss at the radiometer channel frequencies to minimize the overall receiver noise figure. Total power radiometers are limited in accuracy due to the continuous variation in gain of the receiver. High-frequency SPDT switches were developed in the form of monolithic microwave integrated circuits (MMICs) using 75 micron indium phosphide (InP) PIN-diode technology. These switches can be easily integrated into Dicke switched radiometers that utilize microstrip technology.
Anaerobic Work Capacity derived from isokinetic and isoinertial cycling.
Wiedemann, M S F; Bosquet, L
2010-02-01
The purpose of this study was to compare Anaerobic Work Capacity (AWC) measured on an isoinertial or an isokinetic bicycle ergometer. Twelve male participants completed two randomly ordered exercise testing sessions including a torque-velocity test followed by a 30-s all-out test on an isokinetic ergometer, or a force-velocity test followed by a Wingate Anaerobic Test on an isoinertial ergometer. Optimal load measured during the force-velocity test on the isoinertial ergometer was 1.13+/-0.11 N.kg(-1). Optimal cadence measured during the torque-velocity test on the isokinetic ergometer was 107+/-13 rpm. Although P(peak) measures were significantly correlated (r=0.77), we found a large difference between them (effect size=2.85) together with wide limits of agreement (bias+/-95%LOA=24+/-12%). The same observation was made with P(mean), but with a smaller magnitude of difference (bias+/-95%LOA=4.2+/-12%; effect size=0.51; r=0.73). This lack of agreement led us to the conclusion that AWC measures obtained during 30-s all-out tests performed on an isoinertial or an isokinetic bicycle ergometer are not necessarily similar and cannot be used interchangeably.
Leuchtgens, H
1993-07-20
In 30 patients with stage NYHA II cardiac insufficiency, a placebo-controlled randomized double-blind study was carried out to determine the efficacy of the Crataegus special extract WS 1442. Treatment duration was 8 weeks, and the substance was administered at a dose of 1 capsule taken twice a day. The main target parameters were alteration in the pressure-x-rate product (PRP) under standardised loading on a bicycle ergometer, and a score of subjective improvement of complaints elicited by a questionnaire. Secondary parameters were exercise tolerance and the change in heart rate and arterial blood pressure. The active substance group showed a statistically significant advantage over placebo in terms of changes in PRP (at a load of 50 W) and the score, but also in the secondary parameter heart rate. In both groups, systolic and diastolic blood pressure was mildly reduced. No adverse reactions occurred.
Tofari, Paul J; Cormack, Stuart J; Ebert, Tammie R; Gardner, A Scott; Kemp, Justin G
2017-10-01
Talent identification (TID) and talent development (TDE) programmes in track sprint cycling use ergometer- and track-based tests to select junior athletes and assess their development. The purpose of this study was to assess which tests are best at monitoring TID and TDE. Ten male participants (16.2 ± 1.1 year; 178.5 ± 6.0 cm and 73.6 ± 7.6 kg) were selected into the national TID squad based on initial testing. These tests consisted of two 6-s maximal sprints on a custom-built ergometer and 4 maximal track-based tests (2 rolling and 2 standing starts) using 2 gear ratios. Magnitude-based inferences and correlation coefficients assessed changes following a 3-month TDE programme. Training elicited meaningful improvements (80-100% likely) in all ergometer parameters. The standing and rolling small gear, track-based effort times were likely and very likely (3.2 ± 2.4% and 3.3 ± 1.9%, respectively) improved by training. Stronger correlations between ergometer- and track-based measures were very likely following training. Ergometer-based testing provides a more sensitive tool than track-based testing to monitor changes in neuromuscular function during the early stages of TDE. However, track-based testing can indicate skill-based improvements in performance when interpreted with ergometer testing. In combination, these tests provide information on overall talent development.
Evolution of the Far-Infrared Cloud at Titan's South Pole
NASA Technical Reports Server (NTRS)
Jennings, Donald E.; Achterberg, R. K.; Cottini, V.; Anderson, C. M.; Flasar, F. M.; Nixon, C. A.; Bjoraker, G. L.; Kunde, V. G.; Carlson, R. C.; Guandique, E.;
2015-01-01
A condensate cloud on Titan identified by its 220 cm (sup -1) far-infrared signature continues to undergo seasonal changes at both the north and south poles. In the north the cloud, which extends from 55 North to the pole, has been gradually decreasing in emission intensity since the beginning of the Cassini mission with a half-life of 3.8 years. The cloud in the south did not appear until 2012 but its intensity has increased rapidly, doubling every year. The shape of the cloud at the South Pole is very different from that in the north. Mapping in December 2013 showed that the condensate emission was confined to a ring with a maximum at 80 South. The ring was centered 4 degrees from Titan's pole. The pattern of emission from stratospheric trace gases like nitriles and complex hydrocarbons (mapped in January 2014) was also offset by 4 degrees, but had a central peak at the pole and a secondary maximum in a ring at about 70 South with a minimum at 80 South. The shape of the gas emissions distribution can be explained by abundances that are high at the atmospheric pole and diminish toward the equator, combined with correspondingly increasing temperatures. We discuss possible causes for the condensate ring. The present rapid build up of the condensate cloud at the South Pole is likely to transition to a gradual decline during 2015-16.
Low-pass filtering of noisy field Schlumberger sounding curves. Part II: Application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghosh, N.; Wadhwa, R.S.; Shrotri, B.S.
1986-02-01
The basic principles of the application of the linear system theory for smoothing noise-degraded d.c. geoelectrical sounding curves were recently established by Patella. A field Schlumberger sounding is presented to demonstrate first their application and validity. To achieve this purpose, firstly it is pointed out that the required smoothing or low-pass filtering can be considered as an intrinsic property of the transformation of original Schlumberger sounding curves into pole-pole (two-electrode) curves. Then the authors sketch a numerical algorithm to perform the transformation, opportunely modified from a known procedure for transforming dipole diagrams into Schlumberger ones. Finally they show a fieldmore » example with the double aim of demonstrating (i) the high quality of the low-pass filtering, and (ii) the reliability of the transformed pole-pole curve as far as quantitative interpretation is concerned.« less
PoleStriding exercise and vitamin E for management of peripheral vascular disease.
Collins, Eileen G; Edwin Langbein, W; Orebaugh, Cynthia; Bammert, Christine; Hanson, Karla; Reda, Domenic; Edwards, Lonnie C; Littooy, Fred N
2003-03-01
The purpose of this investigation was to evaluate the efficacy of PoleStriding exercise (a form of walking that uses muscles of the upper and lower body in a continuous movement similar to cross-country skiing) and vitamin E (alpha-tocopherol) to improve walking ability and perceived quality of life (QOL) of patients with claudication pain secondary to peripheral arterial disease (PAD). Fifty-two subjects were randomized into four groups: PoleStriding with vitamin E (N = 13), PoleStriding with placebo (N= 14), vitamin E without exercise (N= 13), and placebo without exercise (N = 12). The dose of vitamin E was 400 IU daily. Only the PoleStriding with vitamin E and PoleStriding with placebo groups received PoleStriding instruction and training. Assignment to vitamin E or placebo was double blind. Subjects trained three times weekly for 30-45 min (rest time excluded). Individuals in vitamin E and placebo groups came to the laboratory biweekly for ankle blood-pressure measurements. Results of this randomized clinical trial provide strong evidence that PoleStriding significantly (P< 0.001) improved exercise tolerance on the constant work-rate and incremental treadmill tests. Ratings of perceived claudication pain were significantly less after the PoleStriding training program (P= 0.02). In contrast, vitamin E did not have a statistically significant effect on the subjects' ratings of perceived leg pain (P= 0.35) or treadmill walking duration ( P= 0.36). Perceived distance and walking speed (Walking Impairment Questionnaire) and perceived physical function (Rand Short Form-36) improved in the PoleStriding trained group only (P< 0.001, 0.022 and 0.003, respectively). PoleStriding effectively improved the exercise tolerance and perceived QOL of patients with PAD. Little additional benefit to exercise capacity was realized from vitamin E supplementation.
Rugged switch responds to minute pressure differentials
NASA Technical Reports Server (NTRS)
Friend, L. C.; Shaub, K. D.
1967-01-01
Pressure responsive switching device exhibits high sensitivity but is extremely rugged and resistant to large amplitude shock and velocity loading. This snap-action, single pole-double throw switch operates over a wide temperature range.
Upper pole access is safe and effective for pediatric percutaneous nephrolithotomy.
Oner, Sedat; Karagozlu Akgul, Ahsen; Demirbas, Murat; Onen, Efe; Aydos, Murat; Erdogan, Abdullah
2018-04-01
Upper pole access in percutaneous nephrolithotomy (PCNL) provides a straight tract to the ureter, resulting in easier placement of a guidewire to the ureter, good exposure of the pelvis, calices, and upper ureter, and comfortable manipulations. However, despite these benefits, upper pole access is usually avoided because of the risk of chest complications in both pediatric and adult patients. We aimed to evaluate the safety and morbidity of single upper pole access in pediatric patients undergoing PCNL. We retrospectively reviewed patients aged ≤17 years with renal stones who underwent PCNL with a single access between August 2004 and February 2016. The patients were separated into two groups: the single upper pole access group (SUPAG) and the single other pole access group (SOPAG). We compared the SUPAG and SOPAG in terms of the demographic features of the patients, stone burden and location, operative data, and postoperative outcomes. Complications were classified according to the modified Clavien system. During the study period, 101 PCNL procedures were performed, 77 of which were managed with only one access. The median age of the 77 patients managed with a single access was 12 years (range 3-17 years). The number of cases in the SUPAG and SOPAG was 10 and 67, respectively. There were no statistically significant differences between the SUPAG and SOPAG in terms of age, sex, stone location, hydronephrosis status, stone area, side of kidney, and previous stone treatment or renal surgery. Furthermoret, there were no significant differences between the groups in terms of the operative parameters. Although the difference was insignificant, the median operation times in the SUPAG and SOPAG were 37 and 45 min, respectively. There was no chest complication or bleeding that required transfusion in the SUPAG. Two cases required transfusion, and one case was managed with a double pigtail catheter (double-J) placement because of prolonged extravasation in the SOPAG. The stone-free ratios were 100% and 82.1% in the SUPAG and SOPAG, respectively. Upper pole access provides similar outcomes to other (middle and lower) pole accesses, and may be performed without serious complications. These results indicate that this is a safe and effective approach of PCNL, and it presents a good alternative for removal of renal stones in pediatric patients. Copyright © 2018 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Gause, R. L.; Bynum, B. G. (Inventor)
1973-01-01
An ergometer is described that has a pedal driven direct current motor as a load and includes a frame for supporting the body of a person in either a sitting or a prone position. The pedals may be operated by either the feet or the hands. The electrical circuitry of the ergometer includes means for limiting the load applied to the pedals as a function of work being performed, heart rate, and increases in heart rate.
A low-loss, single-pole, four-throw RF MEMS switch driven by a double stop comb drive
NASA Astrophysics Data System (ADS)
Kang, S.; Kim, H. C.; Chun, K.
2009-03-01
Our goal was to develop a single-pole four-throw (SP4T) radio frequency microelectromechanical system (RF MEMS) switch for band selection in a multi-band, multi-mode, front-end module of a wireless transceiver system. The SP4T RF MEMS switch was based on an arrangement of four single-pole single-throw (SPST) RF MEMS switches. The SP4T RF MEMS switch was driven by a double stop (DS) comb drive, with a lateral resistive contact, and composed of single crystalline silicon (SCS) on glass. A large contact force at a low-drive voltage was achieved by electrostatic actuation of the DS comb drive. Good RF characteristics were achieved by the large contact force and the lateral resistive Au-to-Au contact. Mechanical reliability was achieved by using SCS which has no residual stress as a structure material. The developed SP4T RF MEMS switch has a drive voltage of 15 V, an insertion loss below 0.31 dB at 6 GHz after more than one million cycles under a 10 mW signal, a return loss above 20 dB and an isolation value above 36 dB.
Periodically poled self-frequency-doubling green laser fabricated from Nd:Mg:LiNbO₃ single crystal.
Wang, Dong Zhou; Sun, De Hui; Kang, Xue Liang; Sang, Yuan Hua; Yan, Bo Xia; Liu, Hong; Bi, Yong
2015-07-13
Although a breakthrough in the fabrication of green laser diodes has occurred, the high costs associated with the difficulty of manufacture still present a great obstacle for its practical application. Another approach for producing a green laser, by combining a laser device and a nonlinear crystal, entails the fabrication of complex structures and exhibits unstable performance due to interface contact defects, thus limiting its application. In this work, we report the fabrication by domain engineering of high quality periodically poled LiNbO₃, co-doped with Nd³⁺ and Mg²⁺, which combines a laser medium and a high efficiency second harmonic conversion crystal into a single system that is designed to overcome the above problems. An 80 mW self-frequency doubling green laser was constructed for the first time from a periodically poled Nd:Mg:LiNbO₃ crystal of 16 mm in length. This crystal can be used for developing compact, stable, highly efficient mini-solid-state-lasers, which promise to have many applications in portable laser-based spectroscopy, photo-communications, terahertz wave generation, and laser displays.
VizieR Online Data Catalog: The Washington Visual Double Star Catalog (Mason+ 2001-2014)
NASA Astrophysics Data System (ADS)
Mason, B. D.; Wycoff, G. L.; Hartkopf, W. I.; Douglass, G. G.; Worley, C. E.
2016-03-01
The Washington Visual Double Star Catalog (WDS) is the successor to the Index Catalogue of Visual Double Stars, 1961.0 (IDS; Jeffers and van den Bos, Publ. Lick Obs. 21). Three earlier double star catalogs in XXth century, those by Burnham (BDS, 1906, "General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), Innes (SDS, 1927, "Southern Double Star Catalogue -19 to -90 degrees", Union Observatory, Johannesburg, South Africa), and Aitken (ADS, 1932 "New General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), each covered only a portion of the sky. Both the IDS and the WDS cover the entire sky, and the WDS is intended to contain all known visual double stars for which at least one differential measure has been published. The WDS is continually updated as published data become available. Prior to this, three major updates have been published (Worley and Douglass 1984, "Washington Visual Double Star Catalog, 1984.0", U.S. Naval Observatory, Washington; Worley and Douglass 1997A&AS..125..523W, Cat. I/237; Mason, Wycoff, Hartkopf, Douglass and Worley 2001AJ....122.3466M; and Mason et al. 2006.5). The Washington Double Star Catalog (WDS) has seen numerous changes since the last major release of the catalog. The application of many techniques and considerable industry over the past few years has yielded significant gains in both the number of systems and the number of measures. Is is maintained by the US Naval Observatory, and represents the world's principal database of astrometric double and multiple star information. The WDS contains positions (J2000), discoverer designations, epochs, position angles, separations, magnitudes, spectral types, proper motions, and, when available, Durchmusterung numbers and notes for the components of the systems. (3 data files).
VizieR Online Data Catalog: The Washington Visual Double Star Catalog (Mason+ 2001-2014)
NASA Astrophysics Data System (ADS)
Mason, B. D.; Wycoff, G. L.; Hartkopf, W. I.; Douglass, G. G.; Worley, C. E.
2014-11-01
The Washington Visual Double Star Catalog (WDS) is the successor to the Index Catalogue of Visual Double Stars, 1961.0 (IDS; Jeffers and van den Bos, Publ. Lick Obs. 21). Three earlier double star catalogs in XXth century, those by Burnham (BDS, 1906, "General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), Innes (SDS, 1927, "Southern Double Star Catalogue -19 to -90 degrees", Union Observatory, Johannesburg, South Africa), and Aitken (ADS, 1932 "New General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), each covered only a portion of the sky. Both the IDS and the WDS cover the entire sky, and the WDS is intended to contain all known visual double stars for which at least one differential measure has been published. The WDS is continually updated as published data become available. Prior to this, three major updates have been published (Worley and Douglass 1984, "Washington Visual Double Star Catalog, 1984.0", U.S. Naval Observatory, Washington; Worley and Douglass 1997A&AS..125..523W, Cat. I/237; Mason, Wycoff, Hartkopf, Douglass and Worley 2001AJ....122.3466M; and Mason et al. 2006.5). The Washington Double Star Catalog (WDS) has seen numerous changes since the last major release of the catalog. The application of many techniques and considerable industry over the past few years has yielded significant gains in both the number of systems and the number of measures. Is is maintained by the US Naval Observatory, and represents the world's principal database of astrometric double and multiple star information. The WDS contains positions (J2000), discoverer designations, epochs, position angles, separations, magnitudes, spectral types, proper motions, and, when available, Durchmusterung numbers and notes for the components of the systems. (3 data files).
VizieR Online Data Catalog: The Washington Visual Double Star Catalog (Mason+ 2001-2014)
NASA Astrophysics Data System (ADS)
Mason, B. D.; Wycoff, G. L.; Hartkopf, W. I.; Douglass, G. G.; Worley, C. E.
2015-11-01
The Washington Visual Double Star Catalog (WDS) is the successor to the Index Catalogue of Visual Double Stars, 1961.0 (IDS; Jeffers and van den Bos, Publ. Lick Obs. 21). Three earlier double star catalogs in XXth century, those by Burnham (BDS, 1906, "General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), Innes (SDS, 1927, "Southern Double Star Catalogue -19 to -90 degrees", Union Observatory, Johannesburg, South Africa), and Aitken (ADS, 1932 "New General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), each covered only a portion of the sky. Both the IDS and the WDS cover the entire sky, and the WDS is intended to contain all known visual double stars for which at least one differential measure has been published. The WDS is continually updated as published data become available. Prior to this, three major updates have been published (Worley and Douglass 1984, "Washington Visual Double Star Catalog, 1984.0", U.S. Naval Observatory, Washington; Worley and Douglass 1997A&AS..125..523W, Cat. I/237; Mason, Wycoff, Hartkopf, Douglass and Worley 2001AJ....122.3466M; and Mason et al. 2006.5). The Washington Double Star Catalog (WDS) has seen numerous changes since the last major release of the catalog. The application of many techniques and considerable industry over the past few years has yielded significant gains in both the number of systems and the number of measures. Is is maintained by the US Naval Observatory, and represents the world's principal database of astrometric double and multiple star information. The WDS contains positions (J2000), discoverer designations, epochs, position angles, separations, magnitudes, spectral types, proper motions, and, when available, Durchmusterung numbers and notes for the components of the systems. (3 data files).
VizieR Online Data Catalog: The Washington Visual Double Star Catalog (Mason+ 2001-2012)
NASA Astrophysics Data System (ADS)
Mason, B. D.; Wycoff, G. L.; Hartkopf, W. I.; Douglass, G. G.; Worley, C. E.
2012-11-01
The Washington Visual Double Star Catalog (WDS) is the successor to the Index Catalogue of Visual Double Stars, 1961.0 (IDS; Jeffers and van den Bos, Publ. Lick Obs. 21). Three earlier double star catalogs in XXth century, those by Burnham (BDS, 1906, "General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), Innes (SDS, 1927, "Southern Double Star Catalogue -19 to -90 degrees", Union Observatory, Johannesburg, South Africa), and Aitken (ADS, 1932 "New General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), each covered only a portion of the sky. Both the IDS and the WDS cover the entire sky, and the WDS is intended to contain all known visual double stars for which at least one differential measure has been published. The WDS is continually updated as published data become available. Prior to this, three major updates have been published (Worley and Douglass 1984, "Washington Visual Double Star Catalog, 1984.0", U.S. Naval Observatory, Washington; Worley and Douglass 1997A&AS..125..523W, Cat. I/237; Mason, Wycoff, Hartkopf, Douglass and Worley 2001AJ....122.3466M; and Mason et al. 2006.5). The Washington Double Star Catalog (WDS) has seen numerous changes since the last major release of the catalog. The application of many techniques and considerable industry over the past few years has yielded significant gains in both the number of systems and the number of measures. Is is maintained by the US Naval Observatory, and represents the world's principal database of astrometric double and multiple star information. The WDS contains positions (J2000), discoverer designations, epochs, position angles, separations, magnitudes, spectral types, proper motions, and, when available, Durchmusterung numbers and notes for the components of the systems. (3 data files).
VizieR Online Data Catalog: The Washington Visual Double Star Catalog (Mason+ 2001-2013)
NASA Astrophysics Data System (ADS)
Mason, B. D.; Wycoff, G. L.; Hartkopf, W. I.; Douglass, G. G.; Worley, C. E.
2013-11-01
The Washington Visual Double Star Catalog (WDS) is the successor to the Index Catalogue of Visual Double Stars, 1961.0 (IDS; Jeffers and van den Bos, Publ. Lick Obs. 21). Three earlier double star catalogs in XXth century, those by Burnham (BDS, 1906, "General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), Innes (SDS, 1927, "Southern Double Star Catalogue -19 to -90 degrees", Union Observatory, Johannesburg, South Africa), and Aitken (ADS, 1932 "New General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), each covered only a portion of the sky. Both the IDS and the WDS cover the entire sky, and the WDS is intended to contain all known visual double stars for which at least one differential measure has been published. The WDS is continually updated as published data become available. Prior to this, three major updates have been published (Worley and Douglass 1984, "Washington Visual Double Star Catalog, 1984.0", U.S. Naval Observatory, Washington; Worley and Douglass 1997A&AS..125..523W, Cat. I/237; Mason, Wycoff, Hartkopf, Douglass and Worley 2001AJ....122.3466M; and Mason et al. 2006.5). The Washington Double Star Catalog (WDS) has seen numerous changes since the last major release of the catalog. The application of many techniques and considerable industry over the past few years has yielded significant gains in both the number of systems and the number of measures. Is is maintained by the US Naval Observatory, and represents the world's principal database of astrometric double and multiple star information. The WDS contains positions (J2000), discoverer designations, epochs, position angles, separations, magnitudes, spectral types, proper motions, and, when available, Durchmusterung numbers and notes for the components of the systems. (3 data files).
VizieR Online Data Catalog: The Washington Visual Double Star Catalog (Mason+ 2001-2014)
NASA Astrophysics Data System (ADS)
Mason, B. D.; Wycoff, G. L.; Hartkopf, W. I.; Douglass, G. G.; Worley, C. E.
2017-11-01
The Washington Visual Double Star Catalog (WDS) is the successor to the Index Catalogue of Visual Double Stars, 1961.0 (IDS; Jeffers and van den Bos, Publ. Lick Obs. 21). Three earlier double star catalogs in XXth century, those by Burnham (BDS, 1906, "General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), Innes (SDS, 1927, "Southern Double Star Catalogue -19 to -90 degrees", Union Observatory, Johannesburg, South Africa), and Aitken (ADS, 1932 "New General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), each covered only a portion of the sky. Both the IDS and the WDS cover the entire sky, and the WDS is intended to contain all known visual double stars for which at least one differential measure has been published. The WDS is continually updated as published data become available. Prior to this, three major updates have been published (Worley and Douglass 1984, "Washington Visual Double Star Catalog, 1984.0", U.S. Naval Observatory, Washington; Worley and Douglass 1997A&AS..125..523W, Cat. I/237; Mason, Wycoff, Hartkopf, Douglass and Worley 2001AJ....122.3466M; and Mason et al. 2006.5). The Washington Double Star Catalog (WDS) has seen numerous changes since the last major release of the catalog. The application of many techniques and considerable industry over the past few years has yielded significant gains in both the number of systems and the number of measures. Is is maintained by the US Naval Observatory, and represents the world's principal database of astrometric double and multiple star information. The WDS contains positions (J2000), discoverer designations, epochs, position angles, separations, magnitudes, spectral types, proper motions, and, when available, Durchmusterung numbers and notes for the components of the systems. (3 data files).
VizieR Online Data Catalog: The Washington Visual Double Star Catalog (Mason+ 2001-2014)
NASA Astrophysics Data System (ADS)
Mason, B. D.; Wycoff, G. L.; Hartkopf, W. I.; Douglass, G. G.; Worley, C. E.
2018-06-01
The Washington Visual Double Star Catalog (WDS) is the successor to the Index Catalogue of Visual Double Stars, 1961.0 (IDS; Jeffers and van den Bos, Publ. Lick Obs. 21). Three earlier double star catalogs in XXth century, those by Burnham (BDS, 1906, "General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), Innes (SDS, 1927, "Southern Double Star Catalogue -19 to -90 degrees", Union Observatory, Johannesburg, South Africa), and Aitken (ADS, 1932 "New General Catalogue of Double Stars within 121 degrees of the North Pole", Carnegie Institution of Washington), each covered only a portion of the sky. Both the IDS and the WDS cover the entire sky, and the WDS is intended to contain all known visual double stars for which at least one differential measure has been published. The WDS is continually updated as published data become available. Prior to this, three major updates have been published (Worley and Douglass 1984, "Washington Visual Double Star Catalog, 1984.0", U.S. Naval Observatory, Washington; Worley and Douglass 1997A&AS..125..523W, Cat. I/237; Mason, Wycoff, Hartkopf, Douglass and Worley 2001AJ....122.3466M; and Mason et al. 2006.5). The Washington Double Star Catalog (WDS) has seen numerous changes since the last major release of the catalog. The application of many techniques and considerable industry over the past few years has yielded significant gains in both the number of systems and the number of measures. Is is maintained by the US Naval Observatory, and represents the world's principal database of astrometric double and multiple star information. The WDS contains positions (J2000), discoverer designations, epochs, position angles, separations, magnitudes, spectral types, proper motions, and, when available, Durchmusterung numbers and notes for the components of the systems. (3 data files).
Lu, Xi; Hui-Chan, Christina Wan-Ying; Tsang, William Wai-Nam
2016-11-01
[Purpose] Exercise has been shown to improve cardiovascular fitness and cognitive function. Whether the inclusion of mind over exercise would increase parasympathetic control of the heart and brain activities more than general exercise at a similar intensity is not known. The aim of this study was to compare the effects of Tai Chi (mind-body exercise) versus arm ergometer cycling (body-focused exercise) on the heart rate variability and prefrontal oxygenation level. [Subjects and Methods] A Tai Chi master was invited to perform Tai Chi and arm ergometer cycling with similar exercise intensity on two separate days. Heart rate variability and prefrontal oxyhemoglobin levels were measured continuously by a RR recorder and near-infrared spectroscopy, respectively. [Results] During Tai Chi exercise, spectral analysis of heart rate variability demonstrated a higher high-frequency power as well as a lower low-frequency/high-frequency ratio than during ergometer cycling, suggesting increased parasympathetic and decreased sympathetic control of the heart. Also, prefrontal oxyhemoglobin and total hemoglobin levels were higher than those during arm ergometer exercise. [Conclusion] These findings suggest that increased parasympathetic control of the heart and prefrontal activities may be associated with Tai Chi practice. Having a "mind" component in Tai Chi could be more beneficial for older adults' cardiac health and cognitive function than body-focused ergometer cycling.
Wang, Shau-Chun; Wei, Hsien-Hung; Chen, Hsiao-Ping; Tsai, Min-Hsuan; Yu, Chun-Ching; Chang, Hsueh-Chia
2008-01-01
A transient 106-fold concentration of double-layer counterions by a high-intensity electric field is demonstrated at the exit pole of a millimeter-sized conducting nanoporous granule that permits ion permeation. The phenomenon is attributed to a unique counterion screening dynamics that transforms half of the surface field into a converging one toward the ejecting pole. The resulting surface conduction flux then funnels a large upstream electro-osmotic convective counterion flux into the injecting hemisphere toward the zero-dimensional gate of the ejecting hemisphere to produce the superconcentration. As the concentrated counterion is ejected into the electroneutral bulk electrolyte, it attracts co-ions and produce a corresponding concentration of the co-ions. This mechanism is also shown to trap and concentrate co-ion microcolloids of micron sizes too (macroions) and hence has potential application in bead-based molecular assays. PMID:19693364
My, T-H; Robin, O; Mhibik, O; Drag, C; Bretenaker, F
2009-03-30
The evolution of the spectrum of a singly resonant optical parametric oscillator based on an MgO-doped periodically poled stoichiometric lithium tantalate crystal is observed when the pump power is varied. The onset of cascade Raman lasing due to stimulated Raman scattering in the nonlinear crystal is analyzed. Spurious frequency doubling and sum-frequency generation phenomena are observed and understood. A strong reduction of the intracavity Raman scattering is obtained by a careful adjustment of the cavity losses.
2012-01-01
Background Magnetic resonance imaging (MRI) is an important tool for cardiac research, and it is frequently used for resting cardiac assessments. However, research into non-pharmacological stress cardiac evaluation is limited. Methods We aimed to design a portable and relatively inexpensive MRI cycle ergometer capable of continuously measuring pedalling workload while patients exercise to maintain target heart rates. Results We constructed and tested an MRI-compatible cycle ergometer for a 1.5 T MRI scanner. Resting and sub-maximal exercise images (at 110 beats per minute) were successfully obtained in 8 healthy adults. Conclusions The MRI-compatible cycle ergometer constructed by our research group enabled cardiac assessments at fixed heart rates, while continuously recording power output by directly measuring pedal force and crank rotation. PMID:22423637
Photocouplings at the pole from pion photoproduction
Ronchen, D.; Doring, M.; Huang, F.; ...
2014-06-24
The reactions γp → π 0p and γp → π +n are analyzed in a semi-phenomenological approach up to E ~ 2.3 GeV. Fits to differential cross section and single and double polarization observables are performed. A good overall reproduction of the available photoproduction data is achieved. The Julich2012 dynamical coupled-channel model -which describes elastic πN scattering and the world data base of the reactions πN → ηN, KΛ, and KΣ at the same time– is employed as the hadronic interaction in the final state. Furthermore, the framework guarantees analyticity and, thus, allows for a reliable extraction of resonance parametersmore » in terms of poles and residues. In particular, the photocouplings at the pole can be extracted and are presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz
This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The TFM has a modular structure with quasi-U stator cores and ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating arrangement to achieve high air gap flux density. The design considerations for this TFM with respect to initial sizing, pole number selection, key design ratios, and pole shaping are presented in this paper. Pole number selection is critical in the design process of a TFM because it affects both the torque density and power factor under fixed magnetic andmore » changing electrical loading. Several key design ratios are introduced to facilitate the design procedure. The effect of pole shaping on back-emf and inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis. A prototype is under construction for experimental verification.« less
Temko, Daniel; Van Gool, Inge C; Rayner, Emily; Glaire, Mark; Makino, Seiko; Brown, Matthew; Chegwidden, Laura; Palles, Claire; Depreeuw, Jeroen; Beggs, Andrew; Stathopoulou, Chaido; Mason, John; Baker, Ann-Marie; Williams, Marc; Cerundolo, Vincenzo; Rei, Margarida; Taylor, Jenny C; Schuh, Anna; Ahmed, Ahmed; Amant, Frédéric; Lambrechts, Diether; Smit, Vincent Thbm; Bosse, Tjalling; Graham, Trevor A; Church, David N; Tomlinson, Ian
2018-03-31
Genomic instability, which is a hallmark of cancer, is generally thought to occur in the middle to late stages of tumourigenesis, following the acquisition of permissive molecular aberrations such as TP53 mutation or whole genome doubling. Tumours with somatic POLE exonuclease domain mutations are notable for their extreme genomic instability (their mutation burden is among the highest in human cancer), distinct mutational signature, lymphocytic infiltrate, and excellent prognosis. To what extent these characteristics are determined by the timing of POLE mutations in oncogenesis is unknown. Here, we have shown that pathogenic POLE mutations are detectable in non-malignant precursors of endometrial and colorectal cancer. Using genome and exome sequencing, we found that multiple driver mutations in POLE-mutant cancers show the characteristic POLE mutational signature, including those in genes conventionally regarded as initiators of tumourigenesis. In POLE-mutant cancers, the proportion of monoclonal predicted neoantigens was similar to that in other cancers, but the absolute number was much greater. We also found that the prominent CD8 + T-cell infiltrate present in POLE-mutant cancers was evident in their precursor lesions. Collectively, these data indicate that somatic POLE mutations are early, quite possibly initiating, events in the endometrial and colorectal cancers in which they occur. The resulting early onset of genomic instability may account for the striking immune response and excellent prognosis of these tumours, as well as their early presentation. © 2018 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of Pathological Society of Great Britain and Ireland. © 2018 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of Pathological Society of Great Britain and Ireland.
Biomechanical and energetic determinants of technique selection in classical cross-country skiing.
Pellegrini, Barbara; Zoppirolli, Chiara; Bortolan, Lorenzo; Holmberg, Hans-Christer; Zamparo, Paola; Schena, Federico
2013-12-01
Classical cross-country skiing can be performed using three main techniques: diagonal stride (DS), double poling (DP), and double poling with kick (DK). Similar to other forms of human and animal gait, it is currently unclear whether technique selection occurs to minimize metabolic cost or to keep some mechanical factors below a given threshold. The aim of this study was to find the determinants of technique selection. Ten male athletes roller skied on a treadmill at different slopes (from 0° to 7° at 10km/h) and speeds (from 6 to 18km/h at 2°). The technique preferred by skiers was gathered for every proposed condition. Biomechanical parameters and metabolic cost were then measured for each condition and technique. Skiers preferred DP for skiing on the flat and they transitioned to DK and then to DS with increasing slope steepness, when increasing speed all skiers preferred DP. Data suggested that selections mainly occur to remain below a threshold of poling force. Second, critically low values of leg thrust time may limit the use of leg-based techniques at high speeds. A small role has been identified for the metabolic cost of locomotion, which determined the selection of DP for flat skiing. Copyright © 2013 Elsevier B.V. All rights reserved.
A 20 GeVs transparent neutrino astronomy from the North Pole?
NASA Astrophysics Data System (ADS)
Fargion, D.; D'Armiento, D.
2011-03-01
Muon neutrino astronomy is drown within a polluted atmospheric neutrino noise: indeed recent ICECUBE neutrino records at (TeVs) couldn't find any muon neutrino point source [R. Abbasi et al. (IceCube Collaboration), arXiv:1010.3980v1] being blurred by such a noisy sky. However at 24 GeV energy atmospheric muon neutrinos, while rising vertically along the terrestrial diameter, should disappear (or be severely depleted) while converting into tau flavor: any rarest vertical E≃12 GeV muon track at South Pole Deep Core volume, pointing back to North Pole, might be tracing mostly a noise-free astrophysical signal. The corresponding Deep Core 6 - 7 - 8 - 9 channels trigger maybe point in those directions and inside that energy range without much background. Analogous ν suppression do not occur so efficiently elsewhere (as SuperKamiokande) because of a much smaller volume, an un-ability to test the muon birth place, its length, its expected energy. Also the smearing of the terrestrial rotation makes Deep Core ideal: along the South-North Pole the solid angle is almost steady, the flavor ν↦ν conversion persist while the Earth is spinning around the stable poles-axis. Therefore Deep Core detector at South Pole, may scan at E≃18-27 GeV energy windows, into a narrow vertical cone Δθ≃30° for a novel ν, ν astronomy almost noise-free, pointing back toward the North Pole. Unfortunately muon (at E≃12 GeV) trace their arrival direction mostly spread around an unique string in a zenith-cone solid angle. To achieve also an azimuth angular resolution a two string detection at once is needed. Therefore the doubling of the Deep Core string number, (two new arrays of six string each, achieving an average detection distance of 36.5 m), is desirable, leading to a larger Deep Core detection mass (more than double) and a sharper zenith and azimuth angular resolution by two-string vertical axis detection. Such an improvement may show a noise free (at least factor ten) muon neutrino astronomy. This enhancement may also be a crucial probe of a peculiar anisotropy foreseen for atmospheric anti-muon, in CPT violated physics versus conserved one, following a hint by recent Minos results.
Fincke uses Cycle Ergometer with Vibration Isolation System (CEVIS)
2009-03-26
ISS018-E-043414 (26 March 2009) --- Astronaut Michael Fincke, Expedition 18 commander, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
In dubio pro silentio - Even Loud Music Does Not Facilitate Strenuous Ergometer Exercise.
Kreutz, Gunter; Schorer, Jörg; Sojke, Dominik; Neugebauer, Judith; Bullack, Antje
2018-01-01
Background: Music listening is wide-spread in amateur sports. Ergometer exercise is one such activity which is often performed with loud music. Aim and Hypotheses: We investigated the effects of electronic music at different intensity levels on ergometer performance (physical performance, force on the pedal, pedaling frequency), perceived fatigue and heart rate in healthy adults. We assumed that higher sound intensity levels are associated with greater ergometer performance and less perceived effort, particularly for untrained individuals. Methods: Groups of high trained and low trained healthy males ( N = 40; age = 25.25 years; SD = 3.89 years) were tested individually on an ergometer while electronic dance music was played at 0, 65, 75, and 85 dB. Participants assessed their music experience during the experiment. Results: Majorities of participants rated the music as not too loud (65%), motivating (77.50%), appropriate for this sports exercise (90%), and having the right tempo (67.50%). Participants noticed changes in the acoustical environment with increasing intensity levels, but no further effects on any of the physical or other subjective measures were found for neither of the groups. Therefore, the main hypothesis must be rejected. Discussion: These findings suggest that high loudness levels do not positively influence ergometer performance. The high acceptance of loud music and perceived appropriateness could be based on erroneous beliefs or stereotypes. Reasons for the widespread use of loud music in fitness sports needs further investigation. Reducing loudness during fitness exercise may not compromise physical performance or perceived effort.
Schmidt, Thorsten; Berner, Jette; Jonat, Walter; Weisser, Burkhard; Röcken, Christioph; van Mackelenbergh, Marion; Mundhenke, Christoph
2017-01-19
To investigate the safety and efficacy of arm crank ergometry in breast cancer patients after axillary lymph node dissection, with regard to changes in bioelectrical impedance analysis, arm circumference, muscular strength, quality of life and fatigue. Randomized controlled clinical intervention trial. Forty-nine patients with breast cancer after axillary lymph node dissection. Arm crank ergometer training twice-weekly was compared with usual care over 12 weeks. The arm crank ergometer group improved significantly in terms of lean body mass and skeletal muscle mass, and showed a significant decrease in body fat. In the arm crank ergometer group, as well as the usual care group, a significant increase in armpit circumference was detected during the training period. The magnitude of the gain was higher in the usual care group. For all other measured regions of the arm a significant decrease in circumference was seen in both groups. Muscular strength of the upper extremity increased significantly in both groups, with a greater improvement in the arm crank ergometer group. In both groups a non-significant trend towards improvement in quality of life was observed. The arm crank ergometer group showed significant improvements in physical functioning, general fatigue and physical fatigue. These results confirm the feasibility of arm crank ergometer training after axillary lymph node dissection and highlight improvements in strength, quality of life and reduced arm symptoms with this training.
Evolution of the Far-Infrared Cloud at Titan's South Pole
NASA Technical Reports Server (NTRS)
Jennings, Donald E.; Achterberg, R. K.; Cottini, V.; Anderson, C. M.; Flasar, F. M.; Nixon, C. A.; Bjoraker, G. L.; Kunde, V. G.; Carlson, R. C.; Guandique, E.;
2015-01-01
A condensate cloud on Titan identified by its 220 cm-1 far-infrared signature continues to undergo seasonal changes at both the north and south poles. In the north, the cloud, which extends from 55 N to the pole, has been gradually decreasing in emission intensity since the beginning of the Cassini mission with a half-life of 3.8 years. The cloud in the south did not appear until 2012 but its intensity has increased rapidly, doubling every year. The shape of the cloud at the south pole is very different from that in the north. Mapping in 2013 December showed that the condensate emission was confined to a ring with a maximum at 80 S. The ring was centered 4deg from Titan's pole. The pattern of emission from stratospheric trace gases like nitriles and complex hydrocarbons (mapped in 2014 January) was also offset by 4deg, but had a central peak at the pole and a secondary maximum in a ring at about 70 S with a minimum at 80 S. The shape of the gas emission distribution can be explained by abundances that are high at the atmospheric pole and diminish toward the equator, combined with correspondingly increasing temperatures. We discuss possible causes for the condensate ring. The present rapid build up of the condensate cloud at the south pole is likely to transition to a gradual decline from 2015 to 2016. Key words: molecular processes - planets and satellites: atmospheres - planets and satellites: composition - planets and satellites: individual (Titan) - radiation mechanisms: thermal
Voss in Service module with cycle ergometer
2001-03-23
ISS002-E-5732 (23 March 2001) --- James S. Voss, Expedition Two flight engineer, prepares to exercise on the cycle ergometer in the Zvezda Service Module. The image was taken with a digital still camera.
Usachev on cycle ergometer in Service Module
2001-04-27
ISS002-E-6136 (27 April 2001) --- Yury V. Usachev of Rosaviakosmos, Expedition Two mission commander, exercises on the cycle ergometer in the Zvezda Service Module. The image was taken with a digital still camera.
Jedrzejczyk, Daniel; Güther, Reiner; Paschke, Katrin; Jeong, Woo-Jin; Lee, Han-Young; Erbert, Götz
2011-02-01
We report on efficient single-pass, high-power second-harmonic generation in a periodically poled MgO-doped LiNbO3 planar waveguide using a distributed Bragg reflector tapered diode laser as a pump source. A coupling efficiency into the planar waveguide of 73% was realized, and 1.07 W of visible laser light at 532 nm was generated. Corresponding optical and electro-optical conversion efficiencies of 26% and 8.4%, respectively, were achieved. Good agreement between the experimental data and the theoretical predictions was observed.
Wakata on Cycle Ergometer in Lab
2009-05-30
ISS020-E-005790 (30 May 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 20 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Sturckow uses Cycle Ergometer on Middeck (MDDK) during STS-128
2009-08-29
S128-E-006315 (29 Aug. 2009) --- Astronaut Rick Sturckow, STS-128 commander, gives a “thumbs-up” signal while exercising on a bicycle ergometer on the middeck of the Earth-orbiting Space Shuttle Discovery.
Skoluda, Nadine; Strahler, Jana; Schlotz, Wolff; Niederberger, Larissa; Marques, Sofia; Fischer, Susanne; Thoma, Myriam V; Spoerri, Corinne; Ehlert, Ulrike; Nater, Urs M
2015-01-01
The phenomenon of stress is understood as a multidimensional concept which can be captured by psychological and physiological measures. There are various laboratory stress protocols which enable stress to be investigated under controlled conditions. However, little is known about whether these protocols differ with regard to the induced psycho-physiological stress response pattern. In a within-subjects design, 20 healthy young men underwent four of the most common stress protocols (Stroop test [Stroop], cold pressor test [CPT], Trier Social Stress Test [TSST], and bicycle ergometer test [Ergometer]) and a no-stress control condition (rest) in a randomized order. For the multidimensional assessment of the stress response, perceived stress, endocrine and autonomic biomarkers (salivary cortisol, salivary alpha-amylase, and heart rate) were obtained during the experiments. All stress protocols evoked increases in perceived stress levels, with the highest levels in the TSST, followed by Ergometer, Stroop, and CPT. The highest HPA axis response was found in the TSST, followed by Ergometer, CPT, and Stroop, whilst the highest autonomic response was found in the Ergometer, followed by TSST, Stroop, and CPT. These findings suggest that different stress protocols differentially stimulate various aspects of the stress response. Physically demanding stress protocols such as the Ergometer test appear to be particularly suitable for evoking autonomic stress responses, whereas uncontrollable and social-evaluative threatening stressors (such as the TSST) are most likely to elicit HPA axis stress responses. The results of this study may help researchers in deciding which stress protocol to use, depending on the individual research question. Copyright © 2014 Elsevier Ltd. All rights reserved.
In dubio pro silentio – Even Loud Music Does Not Facilitate Strenuous Ergometer Exercise
Kreutz, Gunter; Schorer, Jörg; Sojke, Dominik; Neugebauer, Judith; Bullack, Antje
2018-01-01
Background: Music listening is wide-spread in amateur sports. Ergometer exercise is one such activity which is often performed with loud music. Aim and Hypotheses: We investigated the effects of electronic music at different intensity levels on ergometer performance (physical performance, force on the pedal, pedaling frequency), perceived fatigue and heart rate in healthy adults. We assumed that higher sound intensity levels are associated with greater ergometer performance and less perceived effort, particularly for untrained individuals. Methods: Groups of high trained and low trained healthy males (N = 40; age = 25.25 years; SD = 3.89 years) were tested individually on an ergometer while electronic dance music was played at 0, 65, 75, and 85 dB. Participants assessed their music experience during the experiment. Results: Majorities of participants rated the music as not too loud (65%), motivating (77.50%), appropriate for this sports exercise (90%), and having the right tempo (67.50%). Participants noticed changes in the acoustical environment with increasing intensity levels, but no further effects on any of the physical or other subjective measures were found for neither of the groups. Therefore, the main hypothesis must be rejected. Discussion: These findings suggest that high loudness levels do not positively influence ergometer performance. The high acceptance of loud music and perceived appropriateness could be based on erroneous beliefs or stereotypes. Reasons for the widespread use of loud music in fitness sports needs further investigation. Reducing loudness during fitness exercise may not compromise physical performance or perceived effort. PMID:29867622
MS Guidoni exercises on the cycle ergometer on the middeck of Endeavour
2001-04-25
S100-E-5356 (25 April 2001) --- Astronaut Umberto Guidoni, STS-100 mission specialist representing the European Space Agency (ESA), works out on a bicycle ergometer on the middeck of the Space Shuttle Endeavour.
Two-Pole Caustic Model for High-Energy Lightcurves of Pulsars
NASA Technical Reports Server (NTRS)
Dyks, J.; Rudak, B.
2003-01-01
We present a new model of high-energy lightcurves from rotation powered pulsars. The key ingredient of the model is the gap region (i.e. the region where particle acceleration is taking place and high-energy photons originate) which satisfies the following assumptions: i) the gap region extends from each polar cap to the light cylinder; ii) the gap is thin and confined to the surface of last open magnetic-field lines; iii) photon emissivity is uniform within the gap region. The model lightcurves are dominated by strong peaks (either double or single) of caustic origin. Unlike in other pulsar models with caustic effects, the double peaks arise due to crossing two caustics, each of which is associated with a different magnetic pole. The generic features of the lightcurves are consistent with the observed characteristics of pulsar lightcurves: 1) the most natural (in terms of probability) shape consists of two peaks (separated by 0.4 to 0.5 in phase for large viewing angles); 2) the peaks possess well developed wings; 3) there is a bridge (inter-peak) emission component; 4) there is a non-vanishing off-pulse emission level; 5) the radio pulse occurs before the leading high-energy peak. The model is well suited for four gamma-ray pulsars - Crab, Vela, Geminga and B1951+32 - with double-peak lightcurves exhibiting the peak separation of 0.4 to 0.5 in phase. Hereby, we apply the model to the Vela pulsar. Moreover, we indicate the limitation of the model in accurate reproducing of the lightcurves with single pulses and narrowly separated (about 0.2 in phase) pulse peaks. We also discuss the optical polarization properties for the Crab pulsar in the context of the two-pole caustic model.
Wakata on Cycle Ergometer with Vibration Isolation System (CEVIS)
2009-03-30
ISS018-E-043723 (30 March 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 18/19 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
SKYLAB (SL)-2 PRIME CREW - BLDG. 5 - JSC
1973-03-20
S73-20713 (1 March 1973) --- Astronaut Charles Conrad Jr., commander of the first manned Skylab mission, wipes perspiration from his face following an exercise session on the bicycle ergometer during Skylab training at Johnson Space Center. Conrad is in the work and experiments compartment of the crew quarters of the Skylab Orbital Workshop (OWS) trainer at JSC. In addition to being the prime exercise for the crewmen, the ergometer is also used for the vector-cardiogram test and the metabolic activity experiment. The bicycle ergometer produces measured workloads for use in determining man's metabolic effectiveness. Photo credit: NASA
Skylab-3 Mission Onboard Photograph - Astronaut Bean on Ergometer
NASA Technical Reports Server (NTRS)
1973-01-01
This Skylab-3 onboard photograph shows Astronaut Allen Bean on the ergometer, breathing into the metabolic analyzer. Skylab's Metabolic Activity experiment (M171), a medical evaluation facility, was designed to measure astronauts' metabolic changes while on long-term space missions. The experiment obtained information on astronauts' physiological capabilities and limitations and provided data useful in the design of future spacecraft and work programs. Physiological responses to physical activity was deduced by analyzing inhaled and exhaled air, pulse rate, blood pressure, and other selected variables of the crew while they performed controlled amounts of physical work with a bicycle ergometer.
Salimi, Zohreh; Ferguson-Pell, Martin
2018-06-01
Although wheelchair ergometers provide a safe and controlled environment for studying or training wheelchair users, until recently they had a major disadvantage in only being capable of simulating straight-line wheelchair propulsion. Virtual reality has helped overcome this problem and broaden the usability of wheelchair ergometers. However, for a wheelchair ergometer to be validly used in research studies, it needs to be able to simulate the biomechanics of real world wheelchair propulsion. In this paper, three versions of a wheelchair simulator were developed. They provide a sophisticated wheelchair ergometer in an immersive virtual reality environment. They are intended for manual wheelchair propulsion and all are able to simulate simple translational inertia. In addition, each of the systems reported uses a different approach to simulate wheelchair rotation and accommodate rotational inertial effects. The first system does not provide extra resistance against rotation and relies on merely linear inertia, hypothesizing that it can provide acceptable replication of biomechanics of wheelchair maneuvers. The second and third systems, however, are designed to simulate rotational inertia. System II uses mechanical compensation, and System III uses visual compensation simulating the influence that rotational inertia has on the visual perception of wheelchair movement in response to rotation at different speeds.
46 CFR 111.30-29 - Emergency switchboards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... regulator unit acting on the exciter field, each emergency switchboard must have: (1) A generator field rheostat; (2) A double pole field switch; (3) Discharge clips; and (4) A discharge resistor. (g) Each...
46 CFR 111.30-29 - Emergency switchboards.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... regulator unit acting on the exciter field, each emergency switchboard must have: (1) A generator field rheostat; (2) A double pole field switch; (3) Discharge clips; and (4) A discharge resistor. (g) Each...
Fabrication and analysis of radiofrequency MEMS series capacitive single-pole double-throw switch
NASA Astrophysics Data System (ADS)
Bansal, Deepak; Bajpai, Anuroop; Kumar, Prem; Kaur, Maninder; Rangra, Kamaljit
2016-10-01
A compact radiofrequency (RF) MEMS single-pole double-throw (SPDT) switch based on series capacitive configuration is proposed. The critical process parameters are analyzed to improve the fabrication process. A technique of cold-hot thermal shock for lift-off method is explored. The residual stress in the structure is quantified by lancet test structures that come out to be 51 MPa. Effect of residual stress on actuation voltage is explored, which changes its value from 24 to 22 V. Resonance frequency and switching speed of the switch are 11 kHz and 44 μs, respectively, measured using laser Doppler vibrometer. Measured bandwidth of the SPDT switch is 20 GHz (5 to 25 GHz), which is verified with finite element method simulations in high frequency structure simulator©; and an equivalent LCR circuit in advanced design system©;. Insertion loss of the switch lies in -0.1 to -0.5 dB with isolation better than -20 dB for the above-mentioned bandwidth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz
This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The TFM has a modular structure with quasi-U stator cores and ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating arrangement to achieve high air gap flux density. The design considerations for this TFM with respect to initial sizing, pole number selection, key design ratios, and pole shaping are presented in this paper. Pole number selection is critical in the design process of a TFM because it affects both the torque density and power factor under fixed magnetic andmore » changing electrical loading. Several key design ratios are introduced to facilitate the design procedure. The effect of pole shaping on back-emf and inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis. A prototype is under construction for experimental verification.« less
On the Double Pole Structure of the Λ(1405)
NASA Astrophysics Data System (ADS)
Roca, Luis; Nieves, Juan; Oset, Eulogio
In the last decade there have been increased theoretical and experimental evidences about the existence of two poles associated to the Λ(1405). In this contribution we summarize several recent works presenting a successful strategy to extract the position of the two Λ(1405) poles from experimental photoproduction data on the γp → KπΣ reaction at Jefferson Lab. The idea is based on considering a production mechanism as model independent as possible and implementing the final state interaction of the final meson-baryon pair based on small modifications of the unitary chiral perturbation theory amplitudes. Precise values for the two poles of the Λ(1405) resonance are then provided. On the other hand, we also present other work where we analyze theoretically the Λb → J/ψK-p reaction from where a recent LHCb experiment extracts a Λ(1405) contribution in the K-p spectrum close to threshold and two baryon states of hidden charm in the J/ψ p spectrum, claimed to be pentaquarks. By assuming that the observed narrow state around 4450 MeV has a nature stemming mostly from {\\bar{D}}\
Design Considerations of a Transverse Flux Machine for Direct-Drive Wind Turbine Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz
This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The TFM has a modular structure with quasi-U stator cores and ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating arrangement to achieve high air gap flux density. The design considerations for this TFM with respect to initial sizing, pole number selection, key design ratios, and pole shaping are presented in this paper. Pole number selection is critical in the design process of a TFM because it affects both the torque density and power factor under fixed magnetic andmore » changing electrical loading. Several key design ratios are introduced to facilitate the design procedure. The effect of pole shaping on back-emf and inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis. A prototype is under construction for experimental verification.« less
NASA Astrophysics Data System (ADS)
Wang, Yannan; Xin, Yunchang; Chapuis, Adrien; Yu, Huihui; Liu, Qing
2016-08-01
Rolled Mg alloys often present a basal texture with the (0002) poles slightly tilting from the normal direction (ND) towards the rolling direction. The current work systematically studies the formation of a double-peaked basal texture tilting from the ND towards the transverse direction (TD) of Mg-5.7Zn-0.5Zr (ZK60) plates hot rolled from the as-cast condition. Our results show that a basal texture forms with the two peaks obviously tilting from the ND towards the TD after rolling to reductions over 19 pct at 673 K (400 °C), but does not appear after rolling at 293 K (20 °C). The TD-tilted double peaks of basal poles disappear after annealing, developing a stronger peak of basal poles around the ND. The microstructural examination indicates that this TD-tilted basal texture mainly results from rolling deformation rather than dynamic recrystallization. Crystal plasticity simulation using the VPSC model was used to understand the effect of slips and twinning on the formation of this TD-tilted basal texture. Simulation demonstrates that, compared to prismatic slip, pyramidal slip is more efficient to generate the basal texture tilting towards the TD. The possible mechanisms affecting the activity of non-basal slips are discussed.
Torregrosa, A J; Maestre, H; Fernández-Pousa, C R; Pereda, J A; Capmany, J
2009-08-01
We present a simple technique to integrate an electro-optic Q switch in a periodically poled bulk lithium niobate crystal bounded by two unpoled (monodomain) regions. The technique exploits the high sensitivity to low applied electric fields of the total internal reflection condition in the periodic poled-unpoled boundary for the small grazing incidence angles associated with the diffraction of a focused Gaussian beam that propagates in the periodically poled region with its axis parallel to the boundary. When the arrangement is placed intracavity to a 1064 nm diode-pumped Nd(3+):YVO(4) laser, it performs simultaneously as a Q switch and as a second-harmonic generator, with Q switching starting at applied voltages as low as 1 V over a 500 microm thickness and with no additional optical elements.
NASA Astrophysics Data System (ADS)
Stappel, M.; Steinborn, R.; Kolbe, D.; Walz, J.
2013-07-01
We present a high power single-frequency ytterbium fiber amplifier system with an output power of 30 W at 1091 nm. The amplifier system consists of two stages, a preamplifier stage in which amplified spontaneous emission is efficiently suppressed (>40 dB) and a high power amplifier with an efficiency of 52%. Two different approaches to frequency doubling are compared. We achieve 8.6 W at 545.5 nm by single-pass frequency doubling in a MgO-doped periodically poled stoichiometric LiTaO3 crystal and up to 19.3 W at 545.5 nm by frequency doubling with a lithium-triborate crystal in an external enhancement cavity.
Helms exercises on the middeck ergometer
2001-08-16
STS105-E-5226 (16 August 2001) --- Now a member of the STS-105 crew, departing Expedition Two flight engineer Susan J. Helms works out on the ergometer device on the mid deck of the Space Shuttle Discovery. The image was recorded with a digital still camera.
LBNP/ergometer effects on female cardiovascular and muscle deconditioning in 15d head-down bed rest
NASA Astrophysics Data System (ADS)
Wang, Lin-Jie
2012-07-01
Female has already been an important part of astronaut corps but gender characteristics in weightlessness and countermeasure effects still not clearly elucidated. In this study the LBNP/Ergometer effects on female cardiovascular deconditioning and muscle atrophy in 15d head-down bed rest were explored. 22 female university students were recruited as volunteers that participated in the 15d head-down bed rest. They were divided into control group (Con,n=8), LBNP exercise group (LBNP,n=7) and LBNP combined with ergometer exercise group (LBNP+Ergo, n=7). Grade negative pressures of -10,-20,-30,-40mmHg 20 or 55min were used in LBNP exercise. In ergometer exercises the subjects must maintain 60-80% VO2peak of pre-bed rest at pedal speed of about 70cycle/min for 15min and the entire exercise duration was 30min. LBNP were performed at 6th,8th,10th,12th,and 13th day and Ergometer were operated at 4th,5th,7th,9th,11th day during bed rest. Before and after bed rest, cardiovascular tilt test were performed to evaluate orthostatic intolerance, supine cycle ergometer were used to test the cardiopulmonary function, MRI tests were operated to examine the volume variations of leg muscle groups and isokinetic test were given to test the muscle strength and endurance of knee. 40% of female subjects did not pass the tilt table test after bed rest and exercises made no difference. Compared with pre-BR, VO2max and VO2max /body weight, VO2/HRmax, maximal power and duration significantly decreased in CON group and LBNP group. For the ERGO+LBNP group, there were no visible different in the parameters of cardiopulmonary function except that maximal power and duration decreased. Muscle maximal voluntary contraction and muscle (quadriceps, rectus femoris, gastrocnemius and soleus) volume decreasing in non-predominant leg was larger in Con group than in LBNP+Ergo group. It is suggested that LBNP combined with ergometer in some degrees can counteract the cardiovascular and muscle deconditioning induced by 15d head-down bed rest.
zic-1 Expression in Planarian Neoblasts after Injury Controls Anterior Pole Regeneration
Vásquez-Doorman, Constanza; Petersen, Christian P.
2014-01-01
Mechanisms that enable injury responses to prompt regenerative outgrowth are not well understood. Planarians can regenerate essentially any tissue removed by wounding, even after decapitation, due to robust regulation of adult pluripotent stem cells of the neoblast population. Formation of pole signaling centers involving Wnt inhibitors or Wnt ligands promotes head or tail regeneration, respectively, and this process requires the use of neoblasts early after injury. We used expression profiling of purified neoblasts to identify factors needed for anterior pole formation. Using this approach, we identified zic-1, a Zic-family transcription factor, as transcriptionally activated in a subpopulation of neoblasts near wound sites early in head regeneration. As head regeneration proceeds, the Wnt inhibitor notum becomes expressed in the newly forming anterior pole in zic-1-expressing cells descended from neoblasts. Inhibition of zic-1 by RNAi resulted in a failure to express notum at the anterior pole and to regenerate a head, but did not affect tail regeneration. Both injury and canonical Wnt signaling inhibition are required for zic-1 expression, and double-RNAi experiments suggest zic-1 inhibits Wnt signaling to allow head regeneration. Analysis of neoblast fate determinants revealed that zic-1 controls specification of notum-expressing cells from foxD-expressing neoblasts to form the anterior pole, which organizes subsequent outgrowth. Specialized differentiation programs may in general underlie injury-dependent formation of tissue organizing centers used for regenerative outgrowth. PMID:24992682
Hegge, Ann Magdalen; Bucher, Elias; Ettema, Gertjan; Faude, Oliver; Holmberg, Hans-Christer; Sandbakk, Øyvind
2016-02-01
To characterize gender differences in power output, energetic capacity and exercise efficiency during whole-body (WP), upper-body (UP), and arm poling (AP). Ten male and ten female elite cross-country skiers, matched for international performance level, completed three incremental submaximal tests and a 3-min self-paced performance test on a Concept2 SkiErg. Power output, cardiorespiratory and kinematic variables were monitored. Body composition was determined by dual-energy X-ray absorptiometry. The men demonstrated 87, 97 and 103% higher power output, and 51, 65 and 71% higher VO2peak (L min(−1)) than the women during WP, UP and AP, respectively, while utilizing ~10% more of their running VO2max in all modes (all P < 0.001). The men had 35, 38 and 59% more lean mass in the whole body, upper body and arms (all P < 0.001). The men exhibited greater shoulder and elbow extension at the start of poling and greater trunk flexion at the end of poling (all P < 0.05). The relationship between VO2 and power output did not differ between the men and women. Gender differences in power production and peak aerobic capacity increased sequentially from WP to UP to AP, coinciding with a greater portion of the muscle mass in the arms of the men. Although the men and women employed each poling technique differently, the estimated efficiency of double poling was independent of gender.
Magnus on Cycle Ergometer with Vibration Isolation System (CEVIS) in US Laboratory Destiny
2009-03-22
ISS018-E-042649 (22 March 2009) --- Astronaut Sandra Magnus, STS-119 mission specialist, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station while Space Shuttle Discovery remains docked with the station.
Voss in Service module with cycle ergometer
2001-03-23
ISS002-E-5734 (23 March 2001) --- Astronaut James S. Voss, Expedition Two flight engineer, gives his arms and upper body a workout with the bicycle ergometer facility in the Zvezda Service Module aboard the International Space Station (ISS). The image was recorded with a digital still camera.
NASA Technical Reports Server (NTRS)
Olree, H. D.
1973-01-01
Experiments that were conducted over a 52-month period showed that isometric and isotonic training on the Exer-Genie gave negligible increases in cardiorespiratory fitness whereas training on the ergometer at a programmed pulse rate increased fitness moderately.
MS Dunbar exercises on an ergometer
1998-03-03
S89-E-5202 (25 Jan 1998) --- This Electronic Still Camera (ESC) image shows mission specialist, Bonnie J. Dunbar, payload commander, working out on the bicycle ergometer onboard the Earth-orbiting Space Shuttle Endeavour. This ESC view was taken on January 25, 1998, at 18:36:52 GMT.
Sturckow uses Cycle Ergometer on Middeck (MDDK) during STS-128
2009-08-29
S128-E-006313 (29 Aug. 2009) --- Astronaut Rick Sturckow, STS-128 commander, gives a “thumbs-up” signal while exercising on a bicycle ergometer on the middeck of the Earth-orbiting Space Shuttle Discovery. Astronaut Nicole Stott, mission specialist, is visible at right.
A comparison of electromyography and stroke kinematics during ergometer and on-water rowing.
Fleming, Neil; Donne, Bernard; Mahony, Nicholas
2014-01-01
This study assessed muscle recruitment patterns and stroke kinematics during ergometer and on-water rowing to validate the accuracy of rowing ergometry. Male rowers (n = 10; age 21 ± 2 years, height 1.90 ± 0.05 m and body mass 83.3 ± 4.8 kg) performed 3 × 3 min exercise bouts, at heart and stroke rates equivalent to 75, 85 and 95% VO2peak, on both dynamic and stationary rowing ergometers, and on water. During exercise, synchronised data for surface electromyography (EMG) and 2D kinematics were recorded. Overall muscle activity was quantified by the integration of rmsEMG and averaged for each 10% interval of the stroke cycle. Muscle activity significantly increased in rectus femoris (RF) and vastus medialis (VM) (P <0.01), as exercise intensity increased. Comparing EMG data across conditions revealed significantly (P <0.05) greater RF and VM activity during on-water rowing at discrete 10% intervals of stroke cycle. In addition, the drive/recovery ratio was significantly lower during dynamic ergometry compared to on-water (40 ± 1 vs. 44 ± 1% at 95%, P <0.01). Results suggest that significant differences exist while comparing recruitment and kinematic patterns between on-water and ergometer rowing. These differences may be due to altered acceleration and deceleration of moving masses on-ergometer not perfectly simulating the on-water scenario.
Inflight Exercise Regimen for the 2-Hour Prebreathe Protocol
NASA Technical Reports Server (NTRS)
Foster, Philip P.; Gernhardt, Michael L.; Woodruff, Kristin K.; Schneider, Susan M.; Homick, Jerry L. (Technical Monitor)
2000-01-01
A 10 min aerobic prebreathe exercise up to 75% V-O2(sub max) on a dual-cycle ergometer, included in the 2-hour prebreathe protocol, has been shown to dramatically reduce the incidence of decompression sickness (DCS) at altitude. In-flight only leg ergometry will be available. A balanced exercise was developed using surgical tubing with the ergometer on-orbit. We hypothesize that a 75% V02max workload, individually prescribed, would be achieved using a target heart rate to regulate the intensity of the arm exercise. VO2, heart rate (HR) / ECG, V-CO2 /V-O2, V(sub E), and V(sub T), and rate of perceived exertion (Borg scale) were measured in eleven healthy subjects who passed a US Air Force Class III Physical examination. A V-O2 peak test was performed to assess the sub-maximal exercise prescription. Two series of sub-maximal tests were performed: (1) leg ergometer/hand ergometer and (2) leg ergometer/surgical tubes. We found no significant differences (P > 0.05) in comparing the means for V-O2 and HR between the predicted and measured values during the final 4 minute-stage at "75% V-O2 workload" or between the two types of sub-maximal tests. The prescribed prebreathe sub-maximal exercise performed with flight certified surgical tubes was achieved using the target HR.
Ford uses Cycle Ergometer on MDDK
2009-09-04
S128-E-007532 (4 Sept. 2009) ---- Astronaut Kevin Ford, STS-128 pilot, works out on the bicycle ergometer on the middeck of the Space Shuttle Discovery. The shuttle is currently docked with the International Space Station while the STS-128 astronauts work with the Expedition 20 crewmembers aboard the orbital outpost.
Hernandez uses Cycle Ergometer on MDDK
2009-09-04
S128-E-007534 (4 Sept. 2009) ---- Astronaut Jose Hernandez, STS-128 mission specialist, works out on the bicycle ergometer on the middeck of the Space Shuttle Discovery. The shuttle is currently docked with the International Space Station while the STS-128 astronauts work with the Expedition 20 crewmembers aboard the orbital outpost.
Elimination of double position domains (DPDs) in epitaxial 〈111〉-3C-SiC on Si(111) by laser CVD
NASA Astrophysics Data System (ADS)
Xu, Qingfang; Zhu, Peipei; Sun, Qingyun; Tu, Rong; Yang, Meijun; Zhang, Song; Zhang, Lianmeng; Goto, Takashi; Yan, Jiasheng; Li, Shusen
2017-12-01
Elimination of double position domains (DPDs) in epitaxial 〈111〉-3C-SiC film on Si(111) substrate was conducted by laser chemical vapor deposition (LCVD) without carbonization. Transmission electron microscopy and pole figure were employed to investigate the microstructure and volume fraction of DPDs in the epitaxial layers, respectively. DPDs significantly decreased with decreasing deposition temperature (Tdep) and vanished at Tdep = 1273 K. The mechanism of the elimination of DPDs by LCVD also has been discussed.
Twice electric field poling for engineering multiperiodic Hex-PPLN microstructures
NASA Astrophysics Data System (ADS)
Pagliarulo, Vito; Gennari, Oriella; Rega, Romina; Mecozzi, Laura; Grilli, Simonetta; Ferraro, Pietro
2018-05-01
Satellite bulk ferroelectric domains were observed everywhere around the larger main inverted ferroelectric domains when a Twice Electric Field Poling (TEFP) process is applied on a z-cut lithium niobate substrate. TEFP approach can be very advantageous for engineering multiperiodic poled microstructures in ferroelectrics. In fact, it is very difficult in the experimental practice to avoid underpoling and/or overpoling when structures with different sizes are requested in the same crystal. TEFP was applied to photoresist patterned crystal with 100 μm period and then a second EP step, with a ten-times smaller periodicity of 10 μm, was accomplished on the same sample. The intriguing fact is that the shorter 10 μm pattern disappeared everywhere except that around the larger satellite ferroelectric domains. The formation of this double-periodicity in the reversed ferroelectric domains occurs very easily and in repeatedly way. We have experimentally investigated the formation of such HePPLN structures by an interference microscopy in digital holography (DH) modality. The reported results demonstrate the possibility of fabricating multi-periodic structures and open the way to investigate the possibility to achieve hierarchical PPLN structures by multiple subsequent electric poling processes.
NASA Astrophysics Data System (ADS)
Ahlawat, Anju; Satapathy, S.; Deshmukh, Pratik; Shirolkar, M. M.; Sinha, A. K.; Karnal, A. K.
2017-12-01
In this letter, studies on structural transitions and the effect of electric field poling on magnetoelectric (ME) properties in 0.65Pb (Mg1/3Nb2/3)O3-0.35PbTiO3 (PMN-PT)/NiFe2O4 (NFO) nanocomposites are reported. The composite illustrates dramatic changes in the NFO crystal structure across ferroelectric transition temperature [Curie temperature (Tc) ˜ 450 K] of PMN-PT, while pure NFO does not exhibit any structural change in the temperature range (300 K-650 K). Synchrotron based X-ray diffraction analysis revealed the splitting of NFO peaks across the Tc of PMN-PT in the PMN-PT/NFO composite. Consequently, the anomalies are observed in temperature dependent magnetization of the NFO phase at the Tc of PMN-PT, establishing ME coupling in the PMN-PT/NFO composite. Furthermore, the composite exhibits drastic modification in ME coupling under electrically poled and unpoled conditions. A large self-biased ME effect characterized by non-zero ME response at zero Hbias was observed in electrically poled composites, which was not observed in unpoled PMN-PT/NFO. These results propose an alternative mechanism for intrinsic converse ME effects. The maximum magnetoelectric output was doubled after electrical poling. The observed self-biased converse magnetoelectric effect at room temperature provides potential applications in electrically controlled memory devices and magnetic flux control devices.
Underwater Cycle Ergometry: Power Requirements With and Without Diver Thermal Dress
2009-01-01
cycle ergometers were built at NEDU as successors to the waterproofed Collins Pedal Mate ergometers that are no longer available. A pedal shaft drives...8217 feet to the pedals. In contrast to the large foot cups and neoprene booties used at NEDU, regular bicycle pedals with toe straps2 over canvas shoes
Commander Rominger on a cycle ergometer on the middeck of Endeavour during STS-100
2001-04-23
S100-E-5342 (23 April 2001) --- Astronaut Kent V. Rominger, STS-100 mission commander, economizes his time as he looks over flight data while working out on an ergometer device on the middeck of the Space Shuttle Endeavour. The scene was recorded with a digital still camera.
Song, Gui bin; Park, Eun cho
2015-01-01
[Purpose] The purpose of the study was to determine the effects of training using virtual reality games on balance and gait ability, as well as the psychological characteristics of stroke patients, such as depression and interpersonal relationships, by comparing them with the effects of ergometer training. [Subjects] Forty stroke patients were randomly divided into a virtual reality group (VRG, N = 20) and an ergometer training group (ETG, N = 20). [Methods] VRG performed training using the Xbox Kinect. ETG performed training using an ergometer bicycle. Both groups received training 30 min per day, five times per week, for eight weeks. [Results] Both the VRG and ETG subjects exhibited a significant difference in weight distribution ratio on the paralyzed side and balance ability. Both the VRG and ETG patients showed significant improvement in psychological measures BDI and RCS, after the intervention, and the VRG sowed a more significant increase in BDI than the ETG. [Conclusion] According to the result of this study, virtual reality training and ergometer training were both effective at improving balance, gait abilities, depression, and interpersonal relationships among stroke patients. PMID:26311925
A new mechanically braked bicycle ergometer with electronic read out.
Bonde-Petersen, F
1983-01-01
The ergometer is mechanically braked by a band in series with a spring. Each end of the band passes over one of two spherical ball bearings, and is attached to the free end of a spring steel bar mounted on the same plate as the two ball bearings. By means of a spindle and cogwheel the plate can be tilted in such a way as to vary the tension in the braking band. The spring steel bar is furnished with four strain-gauges coupled as a Wheatstone's bridge. The system forms a differential force transducer measuring the differences in tension between the two ends of the band. A force is, therefore, only recorded if the flywheel is moving, because at rest forces influencing the bar from the band will be opposite and equal. The ergometer offers certain advantages over the conventional mechanically braked ergometers because it has an electronic read out, and it can be used in field studies. It is independent of the attitude in relation to the vertical, and can thus be used on tilting platforms or in weightless conditions.
Demura, Shinichi; Morishita, Koji; Yamada, Takayoshi; Yamaji, Shunsuke; Komatsu, Miho
2011-11-01
L-Ornithine plays an important role in ammonia metabolism via the urea cycle. This study aimed to examine the effect of L-ornithine hydrochloride ingestion on ammonia metabolism and performance after intermittent maximal anaerobic cycle ergometer exercise. Ten healthy young adults (age, 23.8 ± 3.9 year; height, 172.3 ± 5.5 cm; body mass, 67.7 ± 6.1 kg) with regular training experience ingested L-ornithine hydrochloride (0.1 g/kg, body mass) or placebo after 30 s of maximal cycling exercise. Five sets of the same maximal cycling exercise were conducted 60 min after ingestion, and maximal cycling exercise was conducted after a 15 min rest. The intensity of cycling exercise was based on each subject's body mass (0.74 N kg(-1)). Work volume (watt), peak rpm (rpm) before and after intermittent maximal ergometer exercise and the following serum parameters were measured before ingestion, immediately after exercise and 15 min after exercise: ornithine, ammonia, urea, lactic acid and glutamate. Peak rpm was significantly greater with L-ornithine hydrochloride ingestion than with placebo ingestion. Serum ornithine level was significantly greater with L-ornithine hydrochloride ingestion than with placebo ingestion immediately and 15 min after intermittent maximal cycle ergometer exercise. In conclusion, although maximal anaerobic performance may be improved by L-ornithine hydrochloride ingestion before intermittent maximal anaerobic cycle ergometer exercise, the above may not depend on increase of ammonia metabolism with L-ornithine hydrochloride.
Periodically poled potassium niobate for second-harmonic generation at 463 nm.
Meyn, J P; Klein, M E; Woll, D; Wallenstein, R; Rytz, D
1999-08-15
We report on the fabrication and characterization of quasi-phase-matched potassium niobate crystals for second-harmonic generation. Periodic 30-mum -pitch antiparallel ferroelectric domains are fabricated by means of poling in an electrical field. Both birefrigence and periodic phase shift of the generated second harmonic contribute to phase matching when the d(31) nonlinear optical tensor element is used. 3.8 mW of second-harmonic radiation at 463 nm is generated by frequency doubling of the output of master-oscillator power-amplifier diode laser in a 5-mm-long crystal. The measured effective nonlinear coefficient is 3.7pm/V. The measured spectral acceptance bandwidth of 0.25 nm corresponds to the theoretical value.
NASA Astrophysics Data System (ADS)
Chen, Haidong; Che, Wenquan; Zhang, Tianyu; Cao, Yue; Feng, Wenjie
2018-06-01
Half-mode substrate integrated waveguide (HMSIW) switchable unit, built by HMSIW section with loaded single or multi-microstrip shunt stub(s), was proposed in this work. Both shorted and opened stubs were studied, investigated and compared, bandwidth enhancement method for proposed switchable units was proposed and demonstrated. Based on these switchable units, narrowband and broadband HMSIW single-pole-single-through (SPST) switches, SIW SPST switch and SIW/HMSIW-based single-pole-double-through (SPDT) switch were designed, fabricated and measured. Good performances were observed experimentally for these proposed circuits, showing the advantages of proposed concept and an excellent candidate for switchable or reconfigurable SIW/HMSIW circuits or systems.
W-band integrated circuit PIN switches
NASA Astrophysics Data System (ADS)
Tahim, R. S.; Pham, T.; Chang, K.
1986-12-01
Both single-pole single-throw (SPST) and single-pole double-throw (SPDT) PIN switches have been developed at W band using microstrip integrated circuits. In SPST configurations, these switches have less than 1 dB of insertion loss under forward-voltage conditions from 90 to 108 GHz. Isolation greater than 20 dB over 3 GHz and greater than 10 dB over 7 GHz has been achieved. In SPDT configurations, insertion loss of less than 2 dB and isolation of more than 15 dB over 10 GHz (90 to 110 GHz) have been achieved. Beam-lead PIN diodes were used. Major features included mechanical ruggedness, light weight, small size and low-cost manufacturing.
Frequency doubling in poled polymers using anomalous dispersion phase-matching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kowalczyk, T.C.; Singer, K.D.; Cahill, P.A.
1995-10-01
The authors report on a second harmonic generation in a poled polymer waveguide using anomalous dispersion phase-matching. Blue light ({lambda} = 407 nm) was produced by phase-matching the lowest order fundamental and harmonic modes over a distance of 32 {micro}m. The experimental conversion efficiency was {eta} = 1.2 {times} 10{sup {minus}4}, in agreement with theory. Additionally, they discuss a method of enhancing the conversion efficiency for second harmonic generation using anomalous dispersion phase-matching to optimize Cerenkov second harmonic generation. The modeling shows that a combination of phase-matching techniques creates larger conversion efficiencies and reduces critical fabrication requirements of the individualmore » phase-matching techniques.« less
Combination radial and thrust magnetic bearing
NASA Technical Reports Server (NTRS)
Blumenstock, Kenneth A. (Inventor)
2002-01-01
A combination radial and thrust magnetic bearing is disclosed that allows for both radial and thrust axes control of an associated shaft. The combination radial and thrust magnetic bearing comprises a rotor and a stator. The rotor comprises a shaft, and first and second rotor pairs each having respective rotor elements. The stator comprises first and second stator elements and a magnet-sensor disk. In one embodiment, each stator element has a plurality of split-poles and a corresponding plurality of radial force coils and, in another embodiment, each stator element does not require thrust force coils, and radial force coils are replaced by double the plurality of coils serving as an outer member of each split-pole half.
NASA Technical Reports Server (NTRS)
Fox, D. A.
1977-01-01
Solid-state relay (SSR), containing multinode control logic, is operated as normally open, normally closed, or latched. Moreover several can be paralleled to form two-pole or double-throw relays. Versatile unit ends need to design custom control circuit for every relay application. Technique can be extended to incorporate selectable time delay, on operation or release, or pulsed output.
NASA Astrophysics Data System (ADS)
Charpentier, J. F.; Lemarquand, G.
1998-06-01
Radial instability of synchronous motors is important data to design magnetic bearings. Moreover, original motor structures must be proposed to decrease the instability. In this article, four structures with a permanent magnet rotor, six poles, and the same main mechanical dimensions are analyzed and compared. The first concerns a rotor with six tiles of permanent magnets radially magnetized and adhered to an iron core. The second is a rotor with six axial permanent magnets tangentially magnetized and separated by iron pole pieces, where the shaft is amagnetic. The third design proposes a rotor with six contiguous tiles of permanent magnets tangentially magnetized and an amagnetic shaft. In the fourth structure each north pole is made up of two contiguous tiles of permanent magnets tangentially magnetized in opposite direction and each south pole is made up of an iron pole piece. The shaft of this structure is amagnetic. The stator structure and the currents in stator windings produce a six poles flux distribution. A finite element method program is employed to study the forces and the torques. The four structures are designed to provide the same motor performance (torque). The radial instability is modeled by outcentering the rotor. The relationships between the radial force and the type of structure are analyzed. The result is that the third structure is the best solution for fully magnetically levitated rotors. It has a small instability and does not generate any disturbing force whose frequency is the double of the rotation frequency. This structure also has good properties to be used as a radial magnetic bearing.
Meiotic Nuclear Oscillations Are Necessary to Avoid Excessive Chromosome Associations.
Chacón, Mariola R; Delivani, Petrina; Tolić, Iva M
2016-11-01
Pairing of homologous chromosomes is a crucial step in meiosis, which in fission yeast depends on nuclear oscillations. However, how nuclear oscillations help pairing is unknown. Here, we show that homologous loci typically pair when the spindle pole body is at the cell pole and the nucleus is elongated, whereas they unpair when the spindle pole body is in the cell center and the nucleus is round. Inhibition of oscillations demonstrated that movement is required for initial pairing and that prolonged association of loci leads to mis-segregation. The double-strand break marker Rec25 accumulates in elongated nuclei, indicating that prolonged chromosome stretching triggers recombinatory pathways leading to mis-segregation. Mis-segregation is rescued by overexpression of the Holliday junction resolvase Mus81, suggesting that prolonged pairing results in irresolvable recombination intermediates. We conclude that nuclear oscillations exhibit a dual role, promoting initial pairing and restricting the time of chromosome associations to ensure proper segregation. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.
Polarization switching in undoped and La-doped TlInS2 ferroelectric-semiconductors
NASA Astrophysics Data System (ADS)
Seyidov, MirHasan Yu.; Mikailzade, Faik A.; Suleymanov, Rauf A.; Aliyeva, Vafa B.; Mammadov, Tofig G.; Sharifov, Galib M.
2017-12-01
Dielectric hysteresis loops of pure and lanthanum doped TlInS2 ferroelectric-semiconductors were studied at the frequency 50 Hz for different temperatures below the Curie temperature (Tc). It has been revealed that, without any poling procedure, pure TlInS2 exhibits normal single hysteresis loops at T < Tc. After electric field-cooled treatment of TlInS2 the shape of hysteresis loops was strongly affected by corresponding charged deep level defects which were previously activated during the poling process. As a result, an additional defect polarization state from space charges accumulated on the intrinsic deep level defects has been revealed in pure TlInS2 at the temperatures below Tc. Besides, unusual multiple hysteresis loops were observed in La doped TlInS2 at T < Tc after application of different external perturbations (electric field, exposition and memory effect) to the sample. Measurements of the hysteresis loops in TlInS2:La revealed the slim single, double and even triple polarization-electric field (P-E) hysteresis loops. This intriguing phenomenon is attributed to the domain pinning by photo- and electrically active La-impurity centers. The temperature variation of double-hysteresis loop was also investigated. Due to the heat elimination of the random local defect polar moments, the double-hysteresis loops were transformed into a normal single hysteresis loops on increasing the temperature.
Rodríguez-Marí, Adriana; Wilson, Catherine; Titus, Tom A; Cañestro, Cristian; BreMiller, Ruth A; Yan, Yi-Lin; Nanda, Indrajit; Johnston, Adam; Kanki, John P; Gray, Erin M; He, Xinjun; Spitsbergen, Jan; Schindler, Detlev; Postlethwait, John H
2011-03-01
Mild mutations in BRCA2 (FANCD1) cause Fanconi anemia (FA) when homozygous, while severe mutations cause common cancers including breast, ovarian, and prostate cancers when heterozygous. Here we report a zebrafish brca2 insertional mutant that shares phenotypes with human patients and identifies a novel brca2 function in oogenesis. Experiments showed that mutant embryos and mutant cells in culture experienced genome instability, as do cells in FA patients. In wild-type zebrafish, meiotic cells expressed brca2; and, unexpectedly, transcripts in oocytes localized asymmetrically to the animal pole. In juvenile brca2 mutants, oocytes failed to progress through meiosis, leading to female-to-male sex reversal. Adult mutants became sterile males due to the meiotic arrest of spermatocytes, which then died by apoptosis, followed by neoplastic proliferation of gonad somatic cells that was similar to neoplasia observed in ageing dead end (dnd)-knockdown males, which lack germ cells. The construction of animals doubly mutant for brca2 and the apoptotic gene tp53 (p53) rescued brca2-dependent sex reversal. Double mutants developed oocytes and became sterile females that produced only aberrant embryos and showed elevated risk for invasive ovarian tumors. Oocytes in double-mutant females showed normal localization of brca2 and pou5f1 transcripts to the animal pole and vasa transcripts to the vegetal pole, but had a polarized rather than symmetrical nucleus with the distribution of nucleoli and chromosomes to opposite nuclear poles; this result revealed a novel role for Brca2 in establishing or maintaining oocyte nuclear architecture. Mutating tp53 did not rescue the infertility phenotype in brca2 mutant males, suggesting that brca2 plays an essential role in zebrafish spermatogenesis. Overall, this work verified zebrafish as a model for the role of Brca2 in human disease and uncovered a novel function of Brca2 in vertebrate oocyte nuclear architecture.
Rodríguez-Marí, Adriana; Wilson, Catherine; Titus, Tom A.; Cañestro, Cristian; BreMiller, Ruth A.; Yan, Yi-Lin; Nanda, Indrajit; Johnston, Adam; Kanki, John P.; Gray, Erin M.; He, Xinjun; Spitsbergen, Jan; Schindler, Detlev; Postlethwait, John H.
2011-01-01
Mild mutations in BRCA2 (FANCD1) cause Fanconi anemia (FA) when homozygous, while severe mutations cause common cancers including breast, ovarian, and prostate cancers when heterozygous. Here we report a zebrafish brca2 insertional mutant that shares phenotypes with human patients and identifies a novel brca2 function in oogenesis. Experiments showed that mutant embryos and mutant cells in culture experienced genome instability, as do cells in FA patients. In wild-type zebrafish, meiotic cells expressed brca2; and, unexpectedly, transcripts in oocytes localized asymmetrically to the animal pole. In juvenile brca2 mutants, oocytes failed to progress through meiosis, leading to female-to-male sex reversal. Adult mutants became sterile males due to the meiotic arrest of spermatocytes, which then died by apoptosis, followed by neoplastic proliferation of gonad somatic cells that was similar to neoplasia observed in ageing dead end (dnd)-knockdown males, which lack germ cells. The construction of animals doubly mutant for brca2 and the apoptotic gene tp53 (p53) rescued brca2-dependent sex reversal. Double mutants developed oocytes and became sterile females that produced only aberrant embryos and showed elevated risk for invasive ovarian tumors. Oocytes in double-mutant females showed normal localization of brca2 and pou5f1 transcripts to the animal pole and vasa transcripts to the vegetal pole, but had a polarized rather than symmetrical nucleus with the distribution of nucleoli and chromosomes to opposite nuclear poles; this result revealed a novel role for Brca2 in establishing or maintaining oocyte nuclear architecture. Mutating tp53 did not rescue the infertility phenotype in brca2 mutant males, suggesting that brca2 plays an essential role in zebrafish spermatogenesis. Overall, this work verified zebrafish as a model for the role of Brca2 in human disease and uncovered a novel function of Brca2 in vertebrate oocyte nuclear architecture. PMID:21483806
NASA Astrophysics Data System (ADS)
Ng, Jason Clement
Femtosecond laser processing is a flexible, three-dimensional (3D) fabrication technique used to make integrated low-loss photonic devices in fused silica. My work expanded the suite of available optical devices through the design and optimization of linear optical components such as low-loss (< 0.5 dB) curved waveguides, directional couplers (DCs), and Mach-Zehnder interferometers (MZIs). The robustness and consistency of this maturing fabrication process was also reinforced through the scalable design and integration of a more complex, multi-component flat-top interleaver over a wide >70-nm spectral window. My work further complemented femtosecond laser processing with the development of nonlinear device capabilities. While thermal poling is a well known process, significant challenges had restricted the development of nonlinear devices in fused silica. The laser writing process would erase the induced nonlinearity (erasing) while a written waveguide core acted as a barrier to the thermal poling process (blocking). Using second harmonic (SH) microscopy, the effectiveness of thermal poling on laser-written waveguides was systematically analyzed leading to the technique of "double poling", which effectively overcomes the two challenges of erasing and blocking. In this new process the substrate is poled before and after waveguide writing to restore the induced nonlinearity within the vicinity of the waveguide to enable effective poling for inducing a second-order nonlinearity (SON) in fused silica. A new flexible, femtosecond laser based erasure process was also developed to enable quasi-phase matching and to form arbitrarily chirped gratings. Following this result, second harmonic generation (SHG) in a quasiphase-matched (QPM) femtosecond laser written waveguide device was demonstrated. SHG in a chirped QPM structure was also demonstrated to illustrate the flexibility of the femtosecond laser writing technique. These are the first demonstration of frequency doubling in an all-femtosecond-laser-written structure. A maximum SHG conversion efficiency of 1.3 +/- 0.1x10 -11/W-cm-2 was achieved for the fundamental wavelength of 1552.8 nm with a phase-matching bandwidth of 4.4 nm for a 10.0-mm-long waveguide. For a shorter sample, an effective SON of chi(2) = 0:020 +/- 0:002 pm/V was measured. The results collectively demonstrate the versatility of femtosecond laser additive and subtractive fabrication and opens up the development of integrated nonlinear applications and photonic devices for future lab-on-a-chip and lab-in-a-fiber devices.
Shoulder muscle strength in paraplegics before and after kayak ergometer training.
Bjerkefors, Anna; Jansson, Anna; Thorstensson, Alf
2006-07-01
The purpose was to investigate if shoulder muscle strength in post-rehabilitated persons with spinal cord injury (SCI) was affected by kayak ergometer training and to compare shoulder strength in persons with SCI and able-bodied persons. Ten persons with SCI (7 males and 3 females, injury levels T3-T12) performed 60 min kayak ergometer training three times a week for 10 weeks with progressively increased intensity. Maximal voluntary concentric contractions were performed during six shoulder movements: flexion and extension (range of motion 65 degrees ), abduction and adduction (65 degrees ), and external and internal rotation (60 degrees ), with an angular velocity of 30 degrees s(-1). Position specific strength was assessed at three shoulder angles (at the beginning, middle and end of the range of motion) in the respective movements. Test-retests were performed for all measurements before the training and the mean intraclass correlation coefficient was 0.941 (95% CI 0.928-0.954). There was a main effect of kayak ergometer training with increased shoulder muscle strength after training in persons with SCI. The improvements were independent of shoulder movement, and occurred in the beginning and middle positions. A tendency towards lower shoulder muscle strength was observed in the SCI group compared to a matched reference group of able-bodied persons. Thus, it appears that post-rehabilitated persons with SCI have not managed to fully regain/maintain their shoulder muscle strength on a similar level as that of able-bodied persons, and are able to improve their shoulder muscle strength after a period of kayak ergometer training.
NASA Astrophysics Data System (ADS)
Xu, Chang-Qing; Gan, Yi; Sun, Jian
2012-03-01
Laser displays require red, green and blue (RGB) laser sources each with a low-cost, a high wall-plug efficiency, and a small size. However, semiconductor chips that directly emit green light with sufficient power and efficiency are not currently available on the market. A practical solution to the "green" bottleneck is to employ diode pumped solid state laser (DPSSL) technology, in which a frequency doubling crystal is used. In this paper, recent progress of MgO doped periodically poled lithium niobate (MgO:PPLN) frequency doubling optical chips will be presented. It is shown that MgO:PPLN can satisfy all of the requirements for laser displays and is ready for mass production.
Releasing yellow birch saplings and poles
Gayne G. Erdmann; Ralph M., Jr. Peterson
1992-01-01
Yellow birch needs moisture, nutrients, overhead light, and enough space for the crown to expand in order to compete successfully with faster-growing northern hardwoods. By releasing crowns early, you can increase the number of future veneer and saw log trees in a stand and double the growth rate, thus cutting rotations in half. If you delay crown release too long,...
The Reliability of Pedalling Rates Employed in Work Tests on the Bicycle Ergometer.
ERIC Educational Resources Information Center
Bolonchuk, W. W.
The purpose of this study was to determine whether a group of volunteer subjects could produce and maintain a pedalling cadence within an acceptable range of error. This, in turn, would aid in determining the reliability of pedalling rates employed in work tests on the bicycle ergometer. Forty male college students were randomly given four…
Virts on ergometer in U.S. Lab
2014-12-27
ISS042E082884 (12/27/2014) --- Expedition 42 Flight Engineer Terry Virts of NASA straps into the station’s stationary exercise bicycle known as the Cycle Ergometer with Vibration Isolation System (CEVIS). Each crew member spends an average of 2.5 hours a day exercising to combat the negative effects of prolonged weightlessness by maintaining bone and muscle mass and cardiovascular health.
Modeling of breath methane concentration profiles during exercise on an ergometer*
Szabó, Anna; Unterkofler, Karl; Mochalski, Pawel; Jandacka, Martin; Ruzsanyi, Vera; Szabó, Gábor; Mohácsi, Árpád; Teschl, Susanne; Teschl, Gerald; King, Julian
2016-01-01
We develop a simple three compartment model based on mass balance equations which quantitatively describes the dynamics of breath methane concentration profiles during exercise on an ergometer. With the help of this model it is possible to estimate the endogenous production rate of methane in the large intestine by measuring breath gas concentrations of methane. PMID:26828421
Effects of Age on Maximal Work Capacity in Women Aged 18-48 Years.
ERIC Educational Resources Information Center
Hartung, G. Harley; And Others
Fifty-six healthy nontrained women aged 18 to 48 were tested for maximal work capacity on a bicycle ergometer. The women were divided into three age groups. A continuous step-increment bicycle ergometer work test was administered with the workload starting at 150 kpm (kilometers per minute) and 50 pedal rpm (revolutions per minute). The workload…
Frequency-doubled passively Q-switched microchip laser producing 225 ps pulses at 671 nm.
Nikkinen, Jari; Korpijärvi, Ville-Markus; Leino, Iiro; Härkönen, Antti; Guina, Mircea
2016-11-15
We report a 671 nm laser source emitting 225 ps pulses with an average power of 55 mW and a repetition rate of 444 kHz. The system consists of a 1342 nm SESAM Q-switched Nd:YVO4 microchip master oscillator and a dual-stage Nd:YVO4 power amplifier. The 1342 nm signal was frequency-doubled to 671 nm using a periodically poled lithium niobate crystal. This laser source provides a practical alternative for applications requiring high energy picosecond pulses, such as time-gated Raman spectroscopy.
NASA Technical Reports Server (NTRS)
Duffy, Kirsten P.
2016-01-01
NASA Glenn Research Center is investigating hybrid electric and turboelectric propulsion concepts for future aircraft to reduce fuel burn, emissions, and noise. Systems studies show that the weight and efficiency of the electric system components need to be improved for this concept to be feasible. This effort aims to identify design parameters that affect power density and efficiency for a double-Halbach array permanent-magnet ironless axial flux motor configuration. These parameters include both geometrical and higher-order parameters, including pole count, rotor speed, current density, and geometries of the magnets, windings, and air gap.
1973-01-01
This Skylab-2 onboard photograph shows astronaut Charles "Pete" Conrad exercising on a stationary bicycle (ergometer) used for monitoring the metabolism of the astronauts. The ergometer was used to conduct both Vectorcardiogram experiment (M093) and Metabolic Activity experiment (M171). Experiment M093 was a medical evaluation designed to monitor changes in astronauts' cardiovascular systems, while Experiment M171 was to measure astronauts' metabolic changes during long-duration space missions.
Maciejewski, Hugo; Rahmani, Abderrahmane; Chorin, Frédéric; Lardy, Julien; Samozino, Pierre; Ratel, Sébastien
2018-03-12
The purpose of the present study was to investigate whether three different approaches for evaluating squat jump performance were correlated to rowing ergometer performance in elite adolescent rowers. Fourteen young male competitive rowers (15.3 ± 0.6 years), who took part in the French rowing national championships, performed a 1,500-m all-out rowing ergometer performance (P1500) and a squat jump (SJ) test. The performance in SJ was determined by calculating the jump height (HSJ in cm), a jump index (ISJ = HSJ · body mass · gravity, in J) and the mean power output (PSJ in W) from the Samozino et al.'s method. Furthermore, allometric modelling procedures were used to consider the importance of body mass (BM) in the assessment of HSJ, ISJ and PSJ, and their relationships with between P1500 and jump scores. P1500 was significantly correlated to HSJ (r2 = 0.29, P < 0.05), ISJ (r2 = 0.72, P < 0.0001) and PSJ (r2 = 0.86, P < 0.0001). Furthermore, BM explained at least 96% of the relationships between SJ and rowing performances. However, the similarity between both allometric exponents for PSJ and P1500 (1.15 and 1.04, respectively) indicates that BM could influence jump and rowing ergometer performances at the same rate, and that PSJ could be the best correlate of P1500. Therefore, the calculation of power seems to be more relevant than HSJ and ISJ to (i) evaluate jump performance, and (ii) infer the capacity of adolescent rowers to perform 1,500-m all-out rowing ergometer performance, irrespective of their body mass. This could help coaches to improve their training program and potentially identify talented young rowers.
Rabadi, Mh; Galgano, M; Lynch, D; Akerman, M; Lesser, M; Volpe, Bt
2008-12-01
To determine the efficacy of activity-based therapies using arm ergometer or robotic or group occupational therapy for motor recovery of the paretic arm in patients with an acute stroke (< or =4 weeks) admitted to an inpatient rehabilitation facility, and to obtain information to plan a large randomized controlled trial. Prospective, randomized controlled study. Stroke unit in a rehabilitation hospital. Thirty patients with an acute stroke (< or =4 weeks) who had arm weakness (Medical Research Council grade 2 or less at the shoulder joint). Occupational therapy (OT) group (control) (n = 10), arm ergometer (n = 10) or robotic (n = 10) therapy group. All patients received standard, inpatient, post-stroke rehabilitation training for 3 hours a day, plus 12 additional 40-minute sessions of the activity-based therapy. The primary outcome measures were discharge scores in the Fugl-Meyer Assessment Scale for upper limb impairment, Motor Status Scale, total Functional Independence Measure (FIM) and FIM-motor and FIM-cognition subscores. The three groups (OT group versus arm ergometer versus robotic) were comparable on clinical demographic measures except the robotic group was significantly older and there were more haemorrhagic stroke patients in the arm ergometer group. After adjusting for age, stroke type and outcome measures at baseline, a similar degree of improvement in the discharge scores was found in all of the primary outcome measures. This study suggests that activity-based therapies using an arm ergometer or robot when used over shortened training periods have the same effect as OT group therapy in decreasing impairment and improving disability in the paretic arm of severely affected stroke patients in the subacute phase.
Rowing Crew Coordination Dynamics at Increasing Stroke Rates
2015-01-01
In rowing, perfect synchronisation is important for optimal performance of a crew. Remarkably, a recent study on ergometers demonstrated that antiphase crew coordination might be mechanically more efficient by reducing the power lost to within-cycle velocity fluctuations of the boat. However, coupled oscillator dynamics predict the stability of the coordination to decrease with increasing stroke rate, which in case of antiphase may eventually yield breakdowns to in-phase. Therefore, this study examined the effects of increasing stroke rate on in- and antiphase crew coordination in rowing dyads. Eleven experienced dyads rowed on two mechanically coupled ergometers on slides, which allowed the ergometer system to move back and forth as one ‘boat’. The dyads performed a ramp trial in both in- and antiphase pattern, in which stroke rates gradually increased from 30 strokes per minute (spm) to as fast as possible in steps of 2 spm. Kinematics of rowers, handles and ergometers were captured. Two dyads showed a breakdown of antiphase into in-phase coordination at the first stroke rate of the ramp trial. The other nine dyads reached between 34–42 spm in antiphase but achieved higher rates in in-phase. As expected, the coordinative accuracy in antiphase was worse than in in-phase crew coordination, while, somewhat surprisingly, the coordinative variability did not differ between the patterns. Whereas crew coordination did not substantially deteriorate with increasing stroke rate, stroke rate did affect the velocity fluctuations of the ergometers: fluctuations were clearly larger in the in-phase pattern than in the antiphase pattern, and this difference significantly increased with stroke rate. Together, these results suggest that although antiphase rowing is less stable (i.e., less resistant to perturbation), potential on-water benefits of antiphase over in-phase rowing may actually increase with stroke rate. PMID:26185987
ERIC Educational Resources Information Center
Cairney, John; Hay, John; Veldhuizen, Scott; Faught, Brent
2010-01-01
Oxygen consumption at peak physical exertion (VO[subscript 2] maximum) is the most widely used indicator of cardiorespiratory fitness. The purpose of this study was to compare two protocols for its estimation, cycle ergometer testing and the 20 m shuttle run, among children with and without probable developmental coordination disorder (pDCD). The…
Air-braked cycle ergometers: validity of the correction factor for barometric pressure.
Finn, J P; Maxwell, B F; Withers, R T
2000-10-01
Barometric pressure exerts by far the greatest influence of the three environmental factors (barometric pressure, temperature and humidity) on power outputs from air-braked ergometers. The barometric pressure correction factor for power outputs from air-braked ergometers is in widespread use but apparently has never been empirically validated. Our experiment validated this correction factor by calibrating two air-braked cycle ergometers in a hypobaric chamber using a dynamic calibration rig. The results showed that if the power output correction for changes in air resistance at barometric pressures corresponding to altitudes of 38, 600, 1,200 and 1,800 m above mean sea level were applied, then the coefficients of variation were 0.8-1.9% over the range of 160-1,597 W. The overall mean error was 3.0 % but this included up to 0.73 % for the propagated error that was associated with errors in the measurement of: a) temperature b) relative humidity c) barometric pressure d) force, distance and angular velocity by the dynamic calibration rig. The overall mean error therefore approximated the +/- 2.0% of true load that was specified by the Laboratory Standards Assistance Scheme of the Australian Sports Commission. The validity of the correction factor for barometric pressure on power output was therefore demonstrated over the altitude range of 38-1,800 m.
The Measurement of Maximal (Anaerobic) Power Output on a Cycle Ergometer: A Critical Review
Driss, Tarak; Vandewalle, Henry
2013-01-01
The interests and limits of the different methods and protocols of maximal (anaerobic) power (P max) assessment are reviewed: single all-out tests versus force-velocity tests, isokinetic ergometers versus friction-loaded ergometers, measure of P max during the acceleration phase or at peak velocity. The effects of training, athletic practice, diet and pharmacological substances upon the production of maximal mechanical power are not discussed in this review mainly focused on the technical (ergometer, crank length, toe clips), methodological (protocols) and biological factors (muscle volume, muscle fiber type, age, gender, growth, temperature, chronobiology and fatigue) limiting P max in cycling. Although the validity of the Wingate test is questionable, a large part of the review is dedicated to this test which is currently the all-out cycling test the most often used. The biomechanical characteristics specific of maximal and high speed cycling, the bioenergetics of the all-out cycling exercises and the influence of biochemical factors (acidosis and alkalosis, phosphate ions…) are recalled at the beginning of the paper. The basic knowledge concerning the consequences of the force-velocity relationship upon power output, the biomechanics of sub-maximal cycling exercises and the study on the force-velocity relationship in cycling by Dickinson in 1928 are presented in Appendices. PMID:24073413
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkovszky, L. L., E-mail: jenk@bitp.kiev.ua; Kuprash, O. E., E-mail: oleg.kuprash@desy.de; Orava, R., E-mail: risto.orava@cern.ch
The cross sections for single and double diffraction dissociation at low missing masses are calculated for the LHC energies on the basis of the dual (Regge) model under the assumption of a dominant contribution of the exchange of the Pomeron Regge pole. The model reproduces the rich resonance structure in the region of low missing masses M{sub x}. Diffractively excited states lie on the nucleon trajectory M{sub x} supplemented with the isolated Roper resonance. Detailed predictions for the squared momentum transfer and missing-mass dependence of the differential and integrated single and double diffraction dissociation in the kinematical range of presentmore » and future LHC measurements are given.« less
Jechow, Andreas; Schedel, Marco; Stry, Sandra; Sacher, Joachim; Menzel, Ralf
2007-10-15
A continuous-wave distributed feedback diode laser emitting at 976 nm was frequency doubled by the use of a periodically poled lithium niobate waveguide crystal with a channel size of 3 microm x 5 microm and an interaction length of 10 mm. A laser to waveguide coupling efficiency of 75% could be achieved resulting in 304 mW of incident infrared light inside the waveguide. Blue laser light emission of 159 mW at 488 nm has been generated, which equals to a conversion efficiency of 52%. The resulting wall plug efficiency was 7.4%.
STS-46 Pilot Allen uses cycle ergometer on OV-104's middeck
1992-08-08
STS046-24-025 (31 July-8 Aug. 1992) --- Astronaut Andrew M. Allen, STS-46 pilot, exercises on the bicycle ergometer device on the flight deck of the Space Shuttle Atlantis as it makes one of its 127 total orbits for the eight-day mission. Allen, equipped with sensors for monitoring his biological systems during the run, was joined by four other NASA astronauts and two European scientists on the mission.
STS-109 PLT Carey on middeck with ergometer
2002-03-07
STS109-E-5479 (7 March 2002)-- Astronaut Duane G. Carey, STS-109 pilot, takes a leisurely "spin" on the bicycle ergometer on the mid deck of the Space Shuttle Columbia, while waiting to assist Flight Day 7's assigned space walkers--astronaut James H. Newman and Michael J. Massimino. The extravehicular mobility unit (EMU) space suits of the two can be seen in the background. The image was recorded with a digital still camera.
NASA Technical Reports Server (NTRS)
Vasilyeva, V. V.; Korableva, Y. N.; Trunin, V. V.
1980-01-01
A program of exercises was developed and tested, consisting of a 12 minute session on a variable load bicycle ergometer and a 10-11 min. run with brief stretching and resting sessions between. Physical performance capacity was measured before, during, and after the period of the experiment and physical exams conducted. After a 4 month test period involving 30 men, aged 25-35, the program was found to be successful in increasing physical performance capacity. The PWC170 increased an average of 22 percent and maximum oxygen consumption 14 percent. Arterial pressure dropped (120/75 to 114/68), vital capacity of lungs increased by 6 percent, strength of respiratory muscles by 8.8 percent, duration of respiratory delay by 18 percent. Duration of cardiac cycles increased, stress index decreased. Cardiac contraction rate 2 minutes after work on the ergometer decreased from 118 to 102 bt/min.
VALIDATION OF ADULT OMNI PERCEIVED EXERTION SCALES FOR ELLIPTICAL ERGOMETRY12
MAYS, RYAN J.; GOSS, FREDRIC L.; SCHAFER, MARK A.; KIM, KEVIN H.; NAGLE-STILLEY, ELIZABETH F.; ROBERTSON, ROBERT J.
2012-01-01
Summary This investigation examined the validity of newly developed Adult OMNI Elliptical Ergometer Ratings of Perceived Exertion Scales. Sixty men and women performed a graded exercise test on an elliptical ergometer. Oxygen consumption (VO2), heart rate (HR) and ratings of perceived exertion were recorded each stage from the Borg 15 Category Scale and two different OMNI scales. One scale employed an elliptical ergometer format of the OMNI Picture System of Perceived Exertion. The second scale modified verbal, numerical, and pictorial descriptors at the low end of the response range. Concurrent and construct validity were established by the positive relation between ratings of perceived exertion from each OMNI scale with VO2, HR and Borg Scale ratings of perceived exertion (men, r = .94–.97; women, r = .93–.98). Validity was established for both OMNI scales, indicating either metric can be used to estimate ratings of perceived exertion during partial weight bearing exercise. PMID:21319623
Measures of rowing performance.
Smith, T Brett; Hopkins, Will G
2012-04-01
Accurate measures of performance are important for assessing competitive athletes in practi~al and research settings. We present here a review of rowing performance measures, focusing on the errors in these measures and the implications for testing rowers. The yardstick for assessing error in a performance measure is the random variation (typical or standard error of measurement) in an elite athlete's competitive performance from race to race: ∼1.0% for time in 2000 m rowing events. There has been little research interest in on-water time trials for assessing rowing performance, owing to logistic difficulties and environmental perturbations in performance time with such tests. Mobile ergometry via instrumented oars or rowlocks should reduce these problems, but the associated errors have not yet been reported. Measurement of boat speed to monitor on-water training performance is common; one device based on global positioning system (GPS) technology contributes negligible extra random error (0.2%) in speed measured over 2000 m, but extra error is substantial (1-10%) with other GPS devices or with an impeller, especially over shorter distances. The problems with on-water testing have led to widespread use of the Concept II rowing ergometer. The standard error of the estimate of on-water 2000 m time predicted by 2000 m ergometer performance was 2.6% and 7.2% in two studies, reflecting different effects of skill, body mass and environment in on-water versus ergometer performance. However, well trained rowers have a typical error in performance time of only ∼0.5% between repeated 2000 m time trials on this ergometer, so such trials are suitable for tracking changes in physiological performance and factors affecting it. Many researchers have used the 2000 m ergometer performance time as a criterion to identify other predictors of rowing performance. Standard errors of the estimate vary widely between studies even for the same predictor, but the lowest errors (~1-2%) have been observed for peak power output in an incremental test, some measures of lactate threshold and measures of 30-second all-out power. Some of these measures also have typical error between repeated tests suitably low for tracking changes. Combining measures via multiple linear regression needs further investigation. In summary, measurement of boat speed, especially with a good GPS device, has adequate precision for monitoring training performance, but adjustment for environmental effects needs to be investigated. Time trials on the Concept II ergometer provide accurate estimates of a rower's physiological ability to output power, and some submaximal and brief maximal ergometer performance measures can be used frequently to monitor changes in this ability. On-water performance measured via instrumented skiffs that determine individual power output may eventually surpass measures derived from the Concept II.
Photoinduced second-order optical susceptibilities of Er 2O 3 doped TeO 2-GeO 2-PbO glasses
NASA Astrophysics Data System (ADS)
Kassab, L. R. P.; Pinto, R. de A.; Kobayashi, R. A.; Piasecki, M.; Bragiel, P.; Kityk, I. V.
2007-06-01
Second-order optical susceptibilities were established in the optically poled erbium doped tellurite glasses near the melting temperature. The non-linear optical susceptibility was formed by bicolor coherent optical treatment performed by two coherent laser beams originated from 50 ps Nd-YAG laser ( λ = 1.32 μm) exciting the high pressure hydrogen laser cell emitting at 1907 nm. The non-centrosymmetric grating of the medium was created by coherent superposition of the fundamental laser illumination at 1907 nm and the doubled frequency one at 953.5 nm. The maximally all-optically poled SHG occurs for 2% doped Er 2O 3 (in weighting units) TeO 2-GeO 2-PbO glass. It was found that the photoinduced SHG demonstrates a saturation during the photo-treatment of 9-10 min using the two beams polarized at angle about 45° between them. During the coherent bicolor optical treatment it was achieved the value of second-order susceptibility up to 3.6 pm/V at 1907 nm. The optimal ratio between the fundamental beam with power density about 1.1 GW/cm 2 and writing doubled frequency seeding beam about 0.015 GW/cm 2 corresponds to the maximal of photoinduced SHG. For glasses with lower concentration of Er 2O 3, the relaxation of the second-order optical susceptibility is substantially longer and achieves SHG value that corresponds to 80% of the maximal ones. It is necessary to emphasize that efficient optically-poled grating exists only within the narrow temperature range near the glassing temperature. Possible physical mechanisms of the phenomenon observed are discussed. Generally the used glasses possess better parameters than early investigated germinate glasses.
Gait models and mechanical energy in three cross-country skiing techniques.
Pellegrini, Barbara; Zoppirolli, Chiara; Bortolan, Lorenzo; Zamparo, Paola; Schena, Federico
2014-11-01
Fluctuations in mechanical energy of the body center of mass (COM) have been widely analyzed when investigating different gaits in human and animal locomotion. We applied this approach to estimate the mechanical work in cross-country skiing and to identify the fundamental mechanisms of this particular form of locomotion. We acquired movements of body segments, skis, poles and plantar pressures for eight skiers while they roller skied on a treadmill at 14 km h(-1) and a 2 deg slope using three different techniques (diagonal stride, DS; double poling, DP; double poling with kick, DK). The work associated with kinetic energy (KE) changes of COM was not different between techniques; the work against gravity associated with potential energy (PE) changes was higher for DP than for DK and was lowest for DS. Mechanical work against the external environment was 0.87 J m(-1) kg(-1) for DS, 0.70 J m(-1) kg(-1) for DP and 0.79 J m(-1) kg(-1) for DK. The work done to overcome frictional forces, which is negligible in walking and running, was 17.8%, 32.3% and 24.8% of external mechanical work for DS, DP and DK, respectively. The pendulum-like recovery (R%) between PE and KE was ~45%, ~26% and ~9% for DP, DK and DS, respectively, but energy losses by friction are not accounted for in this computation. The pattern of fluctuations of PE and KE indicates that DS can be described as a 'grounded running', where aerial phases are substituted by ski gliding phases, DP can be described as a pendular gait, whereas DK is a combination of both. © 2014. Published by The Company of Biologists Ltd.
MEMS, Ka-Band Single-Pole Double-Throw (SPDT) Switch for Switched Line Phase Shifters
NASA Technical Reports Server (NTRS)
Scardelletti, Maximilian C.; Ponchak, George E.; Varaljay, Nicholas C.
2002-01-01
Ka-band MEMS doubly anchored cantilever beam capacitive shunt devices are used to demonstrate a MEMS SPDT switch fabricated on high resistivity silicon (HRS) utilizing finite ground coplanar waveguide (FGC) transmission lines. The SPDT switch has an insertion loss (IL), return loss (RL), and isolation of 0.3dB, 40dB, and 30 dB, respectively at Ka-band.
Stöggl, Thomas; Müller, Erich; Lindinger, Stefan
2008-09-01
The aims of the study were to: (1) adapt the "double-push" technique from inline skating to cross-country skiing; (2) compare this new skiing technique with the conventional skate skiing cross-country technique; and (3) test the hypothesis that the double-push technique improves skiing speed in a short sprint. 13 elite skiers performed maximum-speed sprints over 100 m using the double-push skate skiing technique and using the conventional "V2" skate skiing technique. Pole and plantar forces, knee angle, cycle characteristics, and electromyography of nine lower body muscles were analysed. We found that the double-push technique could be successfully transferred to cross-country skiing, and that this new technique is faster than the conventional skate skiing technique. The double-push technique was 2.9 +/- 2.2% faster (P < 0.001), which corresponds to a time advantage of 0.41 +/- 0.31 s over 100 m. The double-push technique had a longer cycle length and a lower cycle rate, and it was characterized by higher muscle activity, higher knee extension amplitudes and velocities, and higher peak foot forces, especially in the first phase of the push-off. Also, the foot was more loaded laterally in the double-push technique than in the conventional skate skiing technique.
Huang, Lin; Mills, Arthur K.; Zhao, Yuan; Jones, David J.; Tang, Shuo
2016-01-01
We report on a miniature fiber-optic multiphoton microscopy (MPM) system based on a frequency-doubled femtosecond Er-doped fiber laser. The femtosecond pulses from the laser source are delivered to the miniature fiber-optic probe at 1.58 µm wavelength, where a standard single mode fiber is used for delivery without the need of free-space dispersion compensation components. The beam is frequency-doubled inside the probe by a periodically poled MgO:LiNbO3 crystal. Frequency-doubled pulses at 786 nm with a maximum power of 80 mW and a pulsewidth of 150 fs are obtained and applied to excite intrinsic signals from tissues. A MEMS scanner, a miniature objective, and a multimode collection fiber are further used to make the probe compact. The miniature fiber-optic MPM system is highly portable and robust. Ex vivo multiphoton imaging of mammalian skins demonstrates the capability of the system in imaging biological tissues. The results show that the miniature fiber-optic MPM system using frequency-doubled femtosecond fiber laser can potentially bring the MPM imaging for clinical applications. PMID:27231633
Comparison of the US and Russian Cycle Ergometers
NASA Technical Reports Server (NTRS)
Norcross, Jason; Bentley, Jason R.; Moore, Alan D.; Hagan, R. Donald
2007-01-01
The purpose of this study was to compare the U.S. and Russian cycle ergometers focusing on the mechanical differences of the devices and the physiological differences observed while using the devices. Methods: First, the mechanical loads provided by the U.S. Cycle Ergometer with Vibration Isolation System (CEVIS) and the Russian Veloergometer were measured using a calibration dynamometer. Results were compared and conversion equations were modeled to determine the actual load provided by each device. Second, ten male subjects (32.9 +/- 6.5 yrs, 180.6 +/- 4.4 cm; 81.9 +/- 6.9 kg) experienced with both cycling and exercise testing completed a standardized submaximal exercise test protocol on CEVIS and Veloergometer. The exercise protocol involved 8 sub-maximal workloads each lasting 3 minutes for a total of 24 minutes per session, or until the end of the stage when the subject reached 85% of peak oxygen consumption or age-predicted maximum heart rate (220 - age). The workload started at 50 Watts (W), increased to 100 W, and then increased 25 W every 3 minutes until reaching a peak workload of 250 W. Physiological variables were then compared at each workload by repeated measures ANOVA or paired t-tests (p<0.05). Results: While both CEVIS and Veloergometer produced significantly lower workloads than the displayed workload, CEVIS produced even lower loads than Veloergometer (p<0.05) at each indicated workload. Despite this fact, the only physiological variables that showed a significant difference between the ergometers were VE (125 - 250W), VO2 (175 and 250 W), and VCO2 (175 W). All other physiological data were not statistically different between CEVIS and Veloergometer. Conclusion: Although workloads were different between ergometers, relatively few physiological differences were observed. Therefore, CEVIS workloads of 87.5 - 262.5 W can be rounded to the nearest 25 W increment and performed on the Veloergometer.
Gee, Thomas I; French, Duncan N; Howatson, Glyn; Payton, Stephen J; Berger, Nicolas J; Thompson, Kevin G
2011-11-01
Rowers regularly undertake rowing training within 24 h of performing bouts of strength training; however, the effect of this practice has not been investigated. This study evaluated the impact of a bout of high-intensity strength training on 2,000 m rowing ergometer performance and rowing-specific maximal power. Eight highly trained male club rowers performed baseline measures of five separate, static squat jumps (SSJ) and countermovement jumps (CMJ), maximal rowing ergometer power strokes (PS) and a single 2,000 m rowing ergometer test (2,000 m). Subsequently, participants performed a high-intensity strength training session consisting of various multi-joint barbell exercises. The 2,000 m test was repeated at 24 and 48 h post-ST, in addition SSJ, CMJ and PS tests were performed at these time points and also at 2 h post-ST. Muscle soreness, serum creatine kinase (CK) and lactate dehydrogenase (LDH) were assessed pre-ST and 2, 24 and 48 h post-ST. Following the ST, there were significant elevations in muscle soreness (2 and 24 h, P < 0.01), CK (2, 24 and 48 h, P < 0.01), and LDH (2 h, P < 0.05) in comparison to baseline values. There were significant decrements across all time points for SSJ, CMJ and PS, which ranged between 3 and 10% (P < 0.05). However, 2,000 m performance and related measurements of heart rate and blood lactate were not significantly affected by ST. In summary, a bout of high-intensity strength training resulted in symptoms of muscle damage and decrements in rowing-specific maximal power, but this did not affect 2,000 m rowing ergometer performance in highly trained rowers.
NASA Astrophysics Data System (ADS)
Atkinson, D.; Drohm, J. K.; Johnson, P. W.; Stam, K.
1981-11-01
An approximated form of the Dyson-Schwinger equation for the gluon propagator in quarkless QCD is subjected to nonlinear functional and numerical analysis. It is found that solutions exist, and that these have a double pole at the origin of the square of the propagator momentum, together with an accumulation of soft branch points. This analytic structure is strongly suggestive of confinement by infrared slavery.
Pupca, Gheorghe; Miclăuş, Graţian Dragoslav; Bucuraş, Viorel; Iacob, Nicoleta; Sas, Ioan; Matusz, Petru; Tubbs, R Shane; Loukas, Marios
2014-01-01
Crossed fused renal ectopia (CFRE) is the second most common fusion anomalies (FAs) of the kidneys after horseshoe kidney. Crossed fused renal ectopia (CFRE) results from one kidney crossing over to the opposite side and subsequent fusion of the parenchyma of the two kidneys. We report, by multidetector-row computed tomography (MDCT) angiography, an extremely rare case of a left CFRE (L-shaped kidney type), consisting of multiple renal arteries (one main renal artery for the upper renal parenchyma, and three renal arteries (one main and two additional) for the lower renal parenchyma) and two left renal veins, which produced a double nutcracker syndrome (both anterior and posterior). The L-shaped left kidney has a maximum length of 18.5 cm, a maximum width of 10.2 cm, and a maximum thickness of 5.3 cm. The upper pole of the kidney is located at the level of the lower third of T12 vertebral body (4.6 cm left to the mediosagittal plan); the lower pole is located along the lower half of the L5 vertebral body (1.5 cm left to the mediosagittal plan). The following case will focus on the relevant anatomy, embryology, and the clinical significance of this entity.
Divided-pulse nonlinear amplification and simultaneous compression
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hao, Qiang; Zhang, Qingshan; Sun, Tingting
2015-03-09
We report on a fiber laser system delivering 122 fs pulse duration and 600 mW average power at 1560 nm by the interplay between divided pulse amplification and nonlinear pulse compression. A small-core double-clad erbium-doped fiber with anomalous dispersion carries out the pulse amplification and simultaneously compresses the laser pulses such that a separate compressor is no longer necessary. A numeric simulation reveals the existence of an optimum fiber length for producing transform-limited pulses. Furthermore, frequency doubling to 780 nm with 240 mW average power and 98 fs pulse duration is achieved by using a periodically poled lithium niobate crystal at roommore » temperature.« less
Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics.
Bertucci, William; Grappe, Frederic; Groslambert, Alain
2007-05-01
The aim of our study was to compare crank torque profile and perceived exertion between the Monark ergometer (818 E) and two outdoor cycling conditions: level ground and uphill road cycling. Seven male cyclists performed seven tests in seated position at different pedaling cadences: (a) in the laboratory at 60, 80, and 100 rpm; (b) on level terrain at 80 and 100 rpm; and (c) on uphill terrain (9.25% grade) at 60 and 80 rpm. The cyclists exercised for 1 min at their maximal aerobic power. The Monark ergometer and the bicycle were equipped with the SRM Training System (Schoberer, Germany) for the measurement of power output (W), torque (Nxm), pedaling cadence (rpm), and cycling velocity (kmxh-1). The most important findings of this study indicate that at maximal aerobic power the crank torque profiles in the Monark ergometer (818 E) were significantly different (especially on dead points of the crank cycle) and generate a higher perceived exertion compared with road cycling conditions.
Validation of a dual-cycle ergometer for exercise during 100 percent oxygen prebreathing
NASA Technical Reports Server (NTRS)
Wiegman, Janet F.; Ohlhausen, John H.; Webb, James T.; Pilmanis, Andrew A.
1992-01-01
A study has been designed to determine if exercise, while prebreathing 100 percent oxygen prior to decompression, can reduce the current resting-prebreathe time requirements for extravehicular activity and high altitude reconnaissance flight. For that study, a suitable exercise mode was required. Design considerations included space limitations, cost, pressure suit compatibility, ease and maintenance of calibration, accuracy of work output, and assurance that no significant mechanical advantage or disadvantage would be introduced into the system. In addition, the exercise device must enhance denitrogenation by incorporation of both upper and lower body musculature at high levels of oxygen consumption. The purpose of this paper is to describe the specially constructed, dual-cycle ergometer developed for simultaneous arm and leg exercise during prebreathing, and to compare maximal oxygen uptake obtained on the device to that obtained during leg-only cycle ergometry and treadmill testing. Results demonstrate the suitability of the dual-cycle ergometer as an appropriate tool for exercise research during 100 percent oxygen prebreathing.
Cases, Julien; Romain, Cindy; Marín-Pagán, Cristian; Chung, Linda H.; Rubio-Pérez, José Miguel; Laurent, Caroline; Gaillet, Sylvie; Prost-Camus, Emmanuelle; Prost, Michel; Alcaraz, Pedro E.
2017-01-01
Workout capacity is energy-production driven. To produce peak metabolic power outputs, the organism predominantly relies more on anaerobic metabolism, but this undoubtedly has a negative and limiting impact on muscle function and performance. The aim of the study was to evaluate if an innovative polyphenol-based food supplement, PerfLoad®, was able to improve metabolic homeostasis and physical performance during high-intensity exercises under anaerobic conditions. The effect of a supplementation has been investigated on fifteen recreationally-active male athletes during a randomized, double-blind and crossover clinical investigation. The Wingate test, an inducer of an unbalanced metabolism associated to oxidative stress, was used to assess maximum anaerobic power during a high-intensity exercise on a cycle ergometer. Supplementation with PerfLoad® correlated with a significant increase in total power output (5%), maximal peak power output (3.7%), and average power developed (5%), without inducing more fatigue or greater heart rate. Instead, oxidative homeostasis was stabilized in supplemented subjects. Such results demonstrated that PerfLoad® is a natural and efficient solution capable of, similarly to training benefits, helping athletes to improve their physical performance, while balancing their metabolism and reducing exercise-induced oxidative stress. PMID:28441760
Forestieri, Patrícia; Guizilini, Solange; Peres, Monique; Bublitz, Caroline; Bolzan, Douglas W.; Rocco, Isadora S.; Santos, Vinícius B.; Moreira, Rita Simone L.; Breda, João R.; de Almeida, Dirceu R.; Carvalho, Antonio Carlos de C.; Arena, Ross; Gomes, Walter J.
2016-01-01
Objective The purpose of this study was to evaluate the effect of a cycle ergometer exercise program on exercise capacity and inspiratory muscle function in hospitalized patients with heart failure awaiting heart transplantation with intravenous inotropic support. Methods Patients awaiting heart transplantation were randomized and allocated prospectively into two groups: 1) Control Group (n=11) - conventional protocol; and 2) Intervention Group (n=7) - stationary cycle ergometer exercise training. Functional capacity was measured by the six-minute walk test and inspiratory muscle strength assessed by manovacuometry before and after the exercise protocols. Results Both groups demonstrated an increase in six-minute walk test distance after the experimental procedure compared to baseline; however, only the intervention group had a significant increase (P=0.08 and P=0.001 for the control and intervention groups, respectively). Intergroup comparison revealed a greater increase in the intervention group compared to the control (P<0.001). Regarding the inspiratory muscle strength evaluation, the intragroup analysis demonstrated increased strength after the protocols compared to baseline for both groups; statistical significance was only demonstrated for the intervention group, though (P=0.22 and P<0.01, respectively). Intergroup comparison showed a significant increase in the intervention group compared to the control (P<0.01). Conclusion Stationary cycle ergometer exercise training shows positive results on exercise capacity and inspiratory muscle strength in patients with heart failure awaiting cardiac transplantation while on intravenous inotropic support. PMID:27982348
A low-cost Mr compatible ergometer to assess post-exercise phosphocreatine recovery kinetics.
Naimon, Niels D; Walczyk, Jerzy; Babb, James S; Khegai, Oleksandr; Che, Xuejiao; Alon, Leeor; Regatte, Ravinder R; Brown, Ryan; Parasoglou, Prodromos
2017-06-01
To develop a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems to reliably quantify metabolic parameters in human lower leg muscle using phosphorus magnetic resonance spectroscopy. We constructed an MR compatible ergometer using commercially available materials and elastic bands that provide resistance to movement. We recruited ten healthy subjects (eight men and two women, mean age ± standard deviation: 32.8 ± 6.0 years, BMI: 24.1 ± 3.9 kg/m 2 ). All subjects were scanned on a 7 T whole-body magnet. Each subject was scanned on two visits and performed a 90 s plantar flexion exercise at 40% maximum voluntary contraction during each scan. During the first visit, each subject performed the exercise twice in order for us to estimate the intra-exam repeatability, and once during the second visit in order to estimate the inter-exam repeatability of the time constant of phosphocreatine recovery kinetics. We assessed the intra and inter-exam reliability in terms of the within-subject coefficient of variation (CV). We acquired reliable measurements of PCr recovery kinetics with an intra- and inter-exam CV of 7.9% and 5.7%, respectively. We constructed a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems, which allowed us to quantify reliably PCr recovery kinetics in lower leg muscle using 31 P-MRS.
Effects of stroke resistance on rowing economy in club rowers post-season.
Kane, D A; Mackenzie, S J; Jensen, R L; Watts, P B
2013-02-01
In the sport of rowing, increasing the impulse applied to the oar handle during the stroke can result in greater boat velocities; this may be facilitated by increasing the surface area of the oar blade and/or increasing the length of the oars. The purpose of this study was to compare the effects of different rowing resistances on the physiological response to rowing. 5 male and 7 female club rowers completed progressive, incremental exercise tests on an air-braked rowing ergometer, using either low (LO; 100) or high (HI; 150) resistance (values are according to the adjustable "drag factor" setting on the ergometer). Expired air, blood lactate concentration, heart rate, rowing cadence, and ergometer power output were monitored during the tests. LO rowing elicited significantly greater cadences (P<0.01) and heart rates (P<0.05), whereas rowing economy (J · L O(2) equivalents(-1)) was significantly greater during HI rowing (P<0.05). These results suggest that economically, rowing with a greater resistance may be advantageous for performance. Moreover, biomechanical analysis of ergometer rowing support the notion that the impulse generated during the stroke increases positively as a function of rowing resistance. We conclude that an aerobic advantage associated with greater resistance parallels the empirical trend toward larger oar blades in competitive rowing. This may be explained by a greater stroke impulse at the higher resistance. © Georg Thieme Verlag KG Stuttgart · New York.
Improved Electro-Optical Switches
NASA Technical Reports Server (NTRS)
Nelson, Bruce N.; Cooper, Ronald F.
1994-01-01
Improved single-pole, double-throw electro-optical switches operate in switching times less than microsecond developed for applications as optical communication systems and networks of optical sensors. Contain no moving parts. In comparison with some prior electro-optical switches, these are simpler and operate with smaller optical losses. Beam of light switched from one output path to other by applying, to electro-optical crystal, voltage causing polarization of beam of light to change from vertical to horizontal.
Sun, Chao; Yang, Shiwen; Chen, Yikai; Guo, Jixin; Qu, Shiwei
2018-01-09
Electromagnetic waves carrying orbital angular momentum (OAM) in radio frequency range have drawn great attention owing to its potential applications in increasing communication capacity. In this paper, both single-pole single-throw (SPST) switches and single-pole double-throw (SPDT) switches are designed and implemented. Optimal time sequence allows four-dimensional (4-D) circular antenna array to generate multiple OAM-carrying waves as well as enhance the field intensity of each OAM-carrying wave. A novel experimental platform is developed to measure the phase distribution when the transmitting antenna and the receiving antenna operate at different frequencies. The good agreement between the measurement and simulation results demonstrate that 4-D circular antenna array is able to generate multiple OAM modes simultaneously. Furthermore, the superiority of the 4-D circular antenna array in receiving and demodulating multiple OAM-carrying signals is validated through the filter and bit error rate (BER) simulations.
Design and analysis of compact MMIC switches utilising GaAs pHEMTs in 3D multilayer technology
NASA Astrophysics Data System (ADS)
Haris, Norshakila; Kyabaggu, Peter B. K.; Alim, Mohammad A.; Rezazadeh, Ali A.
2017-05-01
In this paper, we demonstrate for the first time the implementation of three-dimensional multilayer technology on GaAs-based pseudomorphic high electron mobility transistor (pHEMT) switches. Two types of pHEMT switches are considered, namely single-pole single-throw (SPST) and single-pole double-throw (SPDT). The design and analysis of the devices are demonstrated first through a simulation of the industry-recognised standard model, TriQuint’s Own Model—Level 3, developed by TriQuint Semiconductor, Inc. From the simulation analysis, three optimised SPST and SPDT pHEMT switches which can address applications ranging from L to X bands, are fabricated and tested. The performance of the pHEMT switches using multilayer technology are comparable to those of the current state-of-the-art pHEMT switches, while simultaneously offering compact circuits with the advantages of integration with other MMIC components.
1973-01-01
This Skylab-3 onboard photograph shows Astronaut Allen Bean on the ergometer, breathing into the metabolic analyzer. Skylab's Metabolic Activity experiment (M171), a medical evaluation facility, was designed to measure astronauts' metabolic changes while on long-term space missions. The experiment obtained information on astronauts' physiological capabilities and limitations and provided data useful in the design of future spacecraft and work programs. Physiological responses to physical activity was deduced by analyzing inhaled and exhaled air, pulse rate, blood pressure, and other selected variables of the crew while they performed controlled amounts of physical work with a bicycle ergometer.
Eom, Seung-Hyun; Seo, Yunsik; Lim, Sungjoon
2015-01-01
In this paper, we propose a paper-based pattern switchable antenna system using inkjet-printing technology for bi-direction sensor applications. The proposed antenna system is composed of two directional bow-tie antennas and a switching network. The switching network consists of a single-pole-double-throw (SPDT) switch and a balun element. A double-sided parallel-strip line (DSPSL) is employed to convert the unbalanced microstrip mode to the balanced strip mode. Two directional bow-tie antennas have different radiation patterns because of the different orientation of the reflectors and antennas. It is demonstrated from electromagnetic (EM) simulation and measurement that the radiation patterns of the proposed antenna are successfully switched by the SPDT switch. PMID:26690443
Variable Permanent Magnet Quadrupole
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mihara, T.; Iwashita, Y.; /Kyoto U.
A permanent magnet quadrupole (PMQ) is one of the candidates for the final focus lens in a linear collider. An over 120 T/m strong variable permanent magnet quadrupole is achieved by the introduction of saturated iron and a 'double ring structure'. A fabricated PMQ achieved 24 T integrated gradient with 20 mm bore diameter, 100 mm magnet diameter and 20 cm pole length. The strength of the PMQ is adjustable in 1.4 T steps, due to its 'double ring structure': the PMQ is split into two nested rings; the outer ring is sliced along the beam line into four partsmore » and is rotated to change the strength. This paper describes the variable PMQ from fabrication to recent adjustments.« less
Eom, Seung-Hyun; Seo, Yunsik; Lim, Sungjoon
2015-12-10
In this paper, we propose a paper-based pattern switchable antenna system using inkjet-printing technology for bi-direction sensor applications. The proposed antenna system is composed of two directional bow-tie antennas and a switching network. The switching network consists of a single-pole-double-throw (SPDT) switch and a balun element. A double-sided parallel-strip line (DSPSL) is employed to convert the unbalanced microstrip mode to the balanced strip mode. Two directional bow-tie antennas have different radiation patterns because of the different orientation of the reflectors and antennas. It is demonstrated from electromagnetic (EM) simulation and measurement that the radiation patterns of the proposed antenna are successfully switched by the SPDT switch.
Precise control of flexible manipulators
NASA Technical Reports Server (NTRS)
Cannon, R. H., Jr.
1984-01-01
Experimental apparatus were developed for physically testing control systems for pointing flexible structures, such as limber spacecraft, for the case that control actuators cannot be collocated with sensors. Structural damping ratios are less than 0.003, each basic configuration of sensor/actuator noncollocation is available, and inertias can be halved or doubled abruptly during control maneuvers, thereby imposing, in particular, a sudden reversal in the plant's pole-zero sequence. First experimental results are presented, including stable control with both collocation and noncollocation.
Opitz, David; Kreutz, Thorsten; Lenzen, Edward; Dillkofer, Benedict; Wahl, Patrick; Montiel-Garcia, Gracia; Graf, Christine; Bloch, Wilhelm; Brixius, Klara
2014-03-01
We investigated the cellular distribution of lactate transporter (MCT1) and its chaperone CD147 (using immunohistochemistry and fluorescence-activated cell sorting) in the erythrocytes of men with non-insulin-dependent type-2 diabetes (NIDDM, n = 11, 61 ± 8 years of age) under acute exercise (ergometer cycling test, World Health Organisation scheme) performed before and after a 3-month strength training program. Cytosolic MCT1 distribution and membraneous CD147 density did not change after acute exercise (ergometer). After the 3-month strength training, MCT1-density was increased and the reaction of MCT1 (but not that of CD147) towards acute exercise (ergometer) was altered. MCT1 localisation was shifted from the centre to the cellular membrane. This resulted in a decrease in the immunohistochemically measured cytosolic MCT1-density. We conclude that strength training alters the acute exercise reaction of MCT1 but not that of CD147 in erythrocytes in patients with NIDDM. This reaction may contribute to long-term normalisation and stabilisation of the regulation of lactate plasma concentration in NIDDM.
Tanabe, Mai; Takahashi, Toshiyuki; Shimoyama, Kazuhiro; Toyoshima, Yukako; Ueno, Toshiaki
2013-10-28
The aim of this study was to investigate the influences of rehydration and food consumption on salivary flow, pH, and buffering capacity during bicycle ergometer exercise in participants. Ten healthy volunteers exercised on a bicycle ergometer at 80% of their maximal heart rate. These sessions lasted for two periods of 20 min separated by 5-min rest intervals. Volunteers were subjected to one of the following conditions: (1) no water (mineral water) or food consumption, (2) only water for rehydration, (3) water and food consumption, (4) a sports drink only for rehydration, and (5) rehydration with a sports drink and food. Statistical significance was assessed using one-way analysis of variance and Dunnett's test (p < 0.05). The salivary pH decreased significantly during and after exercise in conditions 4 and 5. The salivary buffering capacity decreased significantly during exercise and/or after the exercise in conditions 1, 3, 4, and 5. The results showed that salivary pH and buffering capacity decreased greatly depending on the combination of a sports drink and food.
Effect of two doses of inhaled diltiazem on exercise-induced asthma.
Foresi, A; Corbo, G M; Ciappi, G; Valente, S; Polidori, G
1987-01-01
Seven asthmatic children with moderately to severely increased bronchial responsiveness to methacholine took part in a double-blind placebo-controlled study to assess the effect of a calcium channel blocker, diltiazem, on exercise-induced asthma (EIA), and its duration. On the control day, bronchial response to exercise was found to be highly reproducible when performed 2 h apart (intraclass correlation coefficient 0.92). Normal saline and diltiazem at concentrations of 1.75 and 3.50 mg/ml (estimated nebulized doses 5 and 10 mg, respectively) were given in random order before exercise on a bicycle ergometer. Exercise challenge was performed 20 min and 2 h after each treatment, and bronchial response was expressed as percent fall in the forced expiratory volume in 1 s. In the overall group, diltiazem did not significantly change resting bronchial tone and produced no significant (p = 0.18) attenuation of EIA. An almost complete protection was detected only in two subjects 20 min after diltiazem 10 mg. This limited effect waned 2 h after the administration.
First results from experiments performed with the ESA Anthrorack during the D-2 Spacelab mission.
Kuipers, A
1996-06-01
In 1993 four astronauts performed physiological experiments on the payload "Anthrorack" during the second German Spacelab mission D-2. The Anthrorack set-up is a Spacelab double rack developed under the management of the European Space Agency. It consists of an ECHO machine, a respiratory monitoring system (gas analyzer with flow meter), a blood centrifuge, an ergometer, a finger blood pressure device, ECG, body impedance measurement device and a respiratory inductance plethysmograph. Experiment-specific equipment was used as well. Nineteen investigators performed experiments in the cardiovascular, pulmonary, fluid-renal and nutritional physiology area. Results on central venous pressure, ocular pressure, vascular resistance, cardiac output, tissue thickness and orthostatic intolerance are presented in the cardiovascular area. In the pulmonary area first results are mentioned on O2 transport perfusion and ventilation distribution and breathing pattern. From the fluid-renal experiments, data from diuresis, sodium excretion and hormonal determinations are given. Finally results from glucose metabolism and nitrogen turnover experiments are presented.
First results from experiments performed with the ESA Anthrorack during the D-2 spacelab mission
NASA Astrophysics Data System (ADS)
Kuipers, A.
1996-06-01
In 1993 four astronauts performed physiological experiments on the payload "Anthrorack" during the second German Spacelab mission D-2. The Anthrorack set-up is a Spacelab double rack developed under the management of the European Space Agency. It consists of an ECHO machine, a respiratory monitoring system (gas analyzer with flow meter), a blood centrifuge, an ergometer, a finger blood pressure device, ECG, body impedance measurement device and a respiratory inductance plethysmograph. Experiment-specific equipment was used as well. Nineteen investigators performed experiments in the cardiovascular, pulmonary, fluid-renal and nutritional physiology area. Results on central venous pressure, ocular pressure, vascular resistance, cardiac output, tissue thickness and orthostatic intolerance are presented in the cardiovascular area. In the pulmonary area first results are mentioned on O 2 transport perfusion and ventilation distribution and breathing pattern. From the fluid-renal experiments, data from diuresis, sodium excretion and hormonal determinations are given. Finally results from glucose metabolism and nitrogen turnover experiments are presented.
Nowicky, Alex V; Horne, Sara; Burdett, Richard
2005-03-01
THIS STUDY USED SURFACE ELECTROMYOGRAPHY (SEMG) TO EXAMINE WHETHER THERE WERE DIFFERENCES IN HIP AND TRUNK MUSCLE ACTIVATION DURING THE ROWING CYCLE ON TWO OF THE MOST WIDELY USED AIR BRAKED ERGOMETERS: the Concept 2C and the Rowperfect. sEMG methods were used to record the muscle activity patterns from the right: m. Erector spinae (ES), m. Rectus Abdominus (RA), m. Rectus Femoris (RF) and m. Biceps Femoris (BF) for their contributions as agonist-antagonist pairs underlying hip and trunk extension/flexion. The sEMG activity patterns of these muscles were examined in six young male elite rowers completing a 2 minute set at a moderate training intensity (23 stroke·min(-1) and 1:47.500 m(-1) split time, 300W). The rowers closely maintained the required target pace through visual inspection of the standard LCD display of each ergometer. The measurements of duration of each rowing cycle and onset of each stroke during the test were recorded simultaneously with the sEMG activity through the additional instrumentation of a foot-pressure switch and handle accelerometry. There were no significant differences between the two ergometer designs in group means for: work rate (i.e., rowing speed and stroke rate), metabolic load as measured by mean heart rate, rowing cycle duration, or timing of the stroke in the cycle. 2-D motion analysis of hip and knee motion for the rowing cycle from the video footage taken during the test also revealed no significant differences in the joint range of motion between the ergometers. Ensemble average sEMG activity profiles based on 30+ strokes were obtained for each participant and normalised per 10% intervals of the cycle duration as well as for peak mean sEMG amplitude for each muscle. A repeated measures ANOVA on the sEMG activity per 10% interval for the four muscles contributing to hip and trunk motion during the rowing cycle revealed no significant differences between the Concept 2C and Rowperfect (F = 0.070, df = 1,5, p = 0.802). The outcome of this study suggests that the two different ergometer designs are equally useful for dry land training. Key PointsThe effects of endurance training on HR recovery after exercise and cardiac ANS modulation were investigated in female marathon runners by comparing with untrained controls.Time and frequency domain analysis of HRV was used to investigate cardiac ANS modulation.As compared with untrained controls, the female marathon runners showed faster HR recovery after exercise, which should result from their higher levels of HRV, higher aerobic capacity and exaggerated blood pressure response to exercise.
Nowicky, Alex V.; Horne, Sara; Burdett, Richard
2005-01-01
This study used surface electromyography (sEMG) to examine whether there were differences in hip and trunk muscle activation during the rowing cycle on two of the most widely used air braked ergometers: the Concept 2C and the Rowperfect. sEMG methods were used to record the muscle activity patterns from the right: m. Erector spinae (ES), m. Rectus Abdominus (RA), m. Rectus Femoris (RF) and m. Biceps Femoris (BF) for their contributions as agonist-antagonist pairs underlying hip and trunk extension/flexion. The sEMG activity patterns of these muscles were examined in six young male elite rowers completing a 2 minute set at a moderate training intensity (23 stroke·min-1 and 1:47.500 m-1 split time, 300W). The rowers closely maintained the required target pace through visual inspection of the standard LCD display of each ergometer. The measurements of duration of each rowing cycle and onset of each stroke during the test were recorded simultaneously with the sEMG activity through the additional instrumentation of a foot-pressure switch and handle accelerometry. There were no significant differences between the two ergometer designs in group means for: work rate (i.e., rowing speed and stroke rate), metabolic load as measured by mean heart rate, rowing cycle duration, or timing of the stroke in the cycle. 2-D motion analysis of hip and knee motion for the rowing cycle from the video footage taken during the test also revealed no significant differences in the joint range of motion between the ergometers. Ensemble average sEMG activity profiles based on 30+ strokes were obtained for each participant and normalised per 10% intervals of the cycle duration as well as for peak mean sEMG amplitude for each muscle. A repeated measures ANOVA on the sEMG activity per 10% interval for the four muscles contributing to hip and trunk motion during the rowing cycle revealed no significant differences between the Concept 2C and Rowperfect (F = 0.070, df = 1,5, p = 0.802). The outcome of this study suggests that the two different ergometer designs are equally useful for dry land training. Key Points The effects of endurance training on HR recovery after exercise and cardiac ANS modulation were investigated in female marathon runners by comparing with untrained controls. Time and frequency domain analysis of HRV was used to investigate cardiac ANS modulation. As compared with untrained controls, the female marathon runners showed faster HR recovery after exercise, which should result from their higher levels of HRV, higher aerobic capacity and exaggerated blood pressure response to exercise. PMID:24431957
New Techniques in Characterization of Ferroelectric Materials
NASA Technical Reports Server (NTRS)
Sehirlioglu, Alp
2008-01-01
Two new techniques have been developed to characterize Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) based ferroelectric single crystals: (i) electro-thermal imaging, and (ii) single crystal x-ray diffraction in the transmission mode. (i) Electro-thermal imaging is a remote sensing technique that can detect the polarization direction and poling state of a whole crystal slice. This imaging technique utilizes an IR camera to determine the field induced temperature change and does not require any special or destructive sample preparation. In the resulting images it is possible to distinguish regions of 180 deg domains. This powerful technique can be used remotely during poling to determine the poling state of the crystal to avoid over-poling that can result in inferior properties and/or cracking of the crystals. Electro-thermal imaging produced the first direct observations of polarization rotation. Under bipolar field, the domains near the corners were the first to switch direction. As the field increased above the coercive field, domains at the center part of the crystals switched direction. (ii) X-ray diffraction in the transmission mode has long been used in structure determination of organic crystals and proteins; however, it is not used much to characterize inorganic systems. 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 single crystals were examined by this XRD technique for the first time, and a never-before-seen super-lattice was revealed with a doubling of the unit cell in all three directions, giving a cell volume eight times that of a traditional perovskite unit cell. The significance of the super-lattice peaks increased with poling, indicating a structural contribution to ordering. Lack of such observations by electron diffraction in the transmission electron microscope examinations suggests the presence of a bulk effect.
Biodiversity: invasions by marine life on plastic debris.
Barnes, David K A
2002-04-25
Colonization by alien species poses one of the greatest threats to global biodiversity. Here I investigate the colonization by marine organisms of drift debris deposited on the shores of 30 remote islands from the Arctic to the Antarctic (across all oceans) and find that human litter more than doubles the rafting opportunities for biota, particularly at high latitudes. Although the poles may be protected from invasion by freezing sea surface temperatures, these may be under threat as the fastest-warming areas anywhere are at these latitudes.
Chang, Chih-Wei; Huang, Tzu-Zung; Chang, Wen-Hsin; Tseng, Yi-Chun; Wu, Yu-Tse; Hsu, Mei-Chich
2016-01-01
The purple mangosteen (Garcinia mangostana), known as the "queen of fruit," is widely consumed and unique not only because of its outstanding appearance and flavor but also its remarkable and diverse pharmacological effects. The aim of the present study is to evaluate the effect of acute mangosteen supplementation on physical fatigue during exercise. A randomized, double-blind, placebo-controlled, crossover study was carried out by 12 healthy adults. The participants were randomly assigned to receive acute oral administration of either 250 mL of the mangosteen-based juice (supplementation treatment; 305 mg of α-mangostin and 278 mg of hydroxycitric acid) or a placebo (control treatment) 1 h before cycle ergometer exercise. Time to exhaustion, heart rate, Borg Rating of Perceived Exertion score, blood biochemical markers (namely ammonia, cortisol, creatine kinase, aspartate aminotransferase, alanine aminotransferase, glucose, and lactate), muscle dynamic stiffness, and Profile of Mood States (POMS) were evaluated and recorded. The results showed all parameters we examined were significantly altered by the exercise challenge, which demonstrated they directly reflected the condition of fatigue. However, there were no differences between the two treatments besides a positive impact on the POMS examination. The occurrence of physical fatigue depends on multiple underlying mechanisms. We concluded that acute mangosteen supplementation had no impact on alleviating physical fatigue during exercise.
Fedorova, Ksenia A; Sokolovskii, Grigorii S; Khomylev, Maksim; Livshits, Daniil A; Rafailov, Edik U
2014-12-01
A compact high-power yellow-green continuous wave (CW) laser source based on second-harmonic generation (SHG) in a 5% MgO doped periodically poled congruent lithium niobate (PPLN) waveguide crystal pumped by a quantum-dot fiber Bragg grating (QD-FBG) laser diode is demonstrated. A frequency-doubled power of 90.11 mW at the wavelength of 560.68 nm with a conversion efficiency of 52.4% is reported. To the best of our knowledge, this represents the highest output power and conversion efficiency achieved to date in this spectral region from a diode-pumped PPLN waveguide crystal, which could prove extremely valuable for the deployment of such a source in a wide range of biomedical applications.
Passive mode-locking of a diode-pumped Nd:YVO(4) laser by intracavity SHG in PPKTP.
Iliev, Hristo; Chuchumishev, Danail; Buchvarov, Ivan; Petrov, Valentin
2010-03-15
Experimental results on passive mode-locking of a Nd:YVO(4) laser using intracavity frequency doubling in periodically poled KTP (PPKTP) crystal are reported. Both, negative cascaded chi((2)) lensing and frequency doubling nonlinear mirror (FDNLM) are exploited for the laser mode-locking. The FDNLM based on intensity dependent reflection in the laser cavity ensures self-starting and self-sustaining mode-locking while the cascaded chi((2)) lens process contributes to substantial pulse shortening. This hybrid technique enables generation of stable trains of pulses at high-average output power with several picoseconds pulse width. The pulse repetition rate of the laser is 117 MHz with average output power ranging from 0.5 to 3.1 W and pulse duration from 2.9 to 5.2 ps.
Design of a vibration isolation system for a cycle ergometer to be used onboard the Space Shuttle
NASA Technical Reports Server (NTRS)
Pearson, Lillian; Tait, Steven; Trevino, Maurice
1991-01-01
Low frequency vibrations generated during exercise using the cycle ergometer onboard the Space Shuttle are disrupting sensitive microgravity experiments. The design team is asked by NASA/USRA to generate alternatives for the design of a vibration isolation system for the cycle ergometer. It is the design team's objective to present alternative designs and a problem solution for a vibration isolation system for an exercise cycle ergometer to be used onboard the Space Shuttle. In the development of alternative designs, the design team emphasizes passive systems as opposed to active control systems. This decision is made because the team feels that passive systems are less complex than active control systems, external energy sources are not required, and mass is reduced due to the lack of machinery such as servomotors or compressors typical of active control systems. Eleven alternative designs are developed by the design team. From these alternatives, three active control systems are included to compare the benefits of active and passive systems. Also included in the alternatives is an isolation system designed by an independent engineer that was acquired late in the project. The eight alternatives using passive isolation systems are narrowed down by selection criteria to four considered to be the most promising by the design team. A feasibility analysis is performed on these four passive isolation systems. Based on the feasibility analysis, a final design solution is chosen and further developed. From the development of the design, the design team has concluded that passive systems are not effective at isolating vibrations for the low frequencies considered for this project. Recommendations are made for guidelines of passive isolation design and application of such systems.
Jędrzejko, Maciej; Nowosielski, Krzysztof; Poręba, Ryszard; Ulman-Włodarz, Izabela; Bobiński, Rafał
2016-12-01
To evaluate physical efficiency and activity energy expenditure (AEE) in term pregnancy females during cardiopulmonary exercise tests with a supine cycle ergometer. The study comprised 22 healthy full-term pregnancy women with uncomplicated pregnancies hospitalized in the Department of Gynecology and Obstetrics, Specialist Teaching Hospital in Tychy, Poland. All subjects underwent cardiopulmonary exercise tests (CPET) on a supine cycle ergometer. The 12-min, three-stage, progressive, symptom-limited submaximal test protocol (up to 80% HRmax) was used. Pulsometry was used to record HR on a beat-to-beat analysis and to calculate AEE. Respiratory responses were measured by ergospirometer and a computer system on a breath-by-breath basis at rest, during exercise and at restitution. In the studied population, VO2max was established at the level of 2.19 ± 0.33 L/min in ergospirometry and 2.04 ± 025 L/min in pulsometry. Physical efficiency calculated for sub-maximal exercise by use of the Davis equation was 30.52 ± 0.12%. AEE, based on VO2 in various phases of the CPET, was 0.47, 0.71 and 0.88 L/min for phases 25, 50 and 75 W. Based on ergospirometer readouts, AEE was 10.60, 16.11 and 20.94 kJ/min for phases 25, 50 and 75 W. Overall mean AEE (determined by pulsometry) was 10.59 kJ/min. CPET testing did not have any negative effect upon the health or life of the neonates involved in the study. Submaximal CPET up to 80% HRmax with a supine cycle ergometer is a safe and precise method for assessing work efficiency in term pregnancy women.
Don’t Rock the Boat: How Antiphase Crew Coordination Affects Rowing
de Brouwer, Anouk J.; de Poel, Harjo J.; Hofmijster, Mathijs J.
2013-01-01
It is generally accepted that crew rowing requires perfect synchronization between the movements of the rowers. However, a long-standing and somewhat counterintuitive idea is that out-of-phase crew rowing might have benefits over in-phase (i.e., synchronous) rowing. In synchronous rowing, 5 to 6% of the power produced by the rower(s) is lost to velocity fluctuations of the shell within each rowing cycle. Theoretically, a possible way for crews to increase average boat velocity is to reduce these fluctuations by rowing in antiphase coordination, a strategy in which rowers perfectly alternate their movements. On the other hand, the framework of coordination dynamics explicates that antiphase coordination is less stable than in-phase coordination, which may impede performance gains. Therefore, we compared antiphase to in-phase crew rowing performance in an ergometer experiment. Nine pairs of rowers performed a two-minute maximum effort in-phase and antiphase trial at 36 strokes min−1 on two coupled free-floating ergometers that allowed for power losses to velocity fluctuations. Rower and ergometer kinetics and kinematics were measured during the trials. All nine pairs easily acquired antiphase rowing during the warm-up, while one pair’s coordination briefly switched to in-phase during the maximum effort trial. Although antiphase interpersonal coordination was indeed less accurate and more variable, power production was not negatively affected. Importantly, in antiphase rowing the decreased power loss to velocity fluctuations resulted in more useful power being transferred to the ergometer flywheels. These results imply that antiphase rowing may indeed improve performance, even without any experience with antiphase technique. Furthermore, it demonstrates that although perfectly synchronous coordination may be the most stable, it is not necessarily equated with the most efficient or optimal performance. PMID:23383024
Combining ergometer exercise and artificial gravity in a compact-radius centrifuge
NASA Astrophysics Data System (ADS)
Diaz, Ana; Trigg, Chris; Young, Laurence R.
2015-08-01
Humans experience physiological deconditioning during space missions, primarily attributable to weightlessness. Some of these adverse consequences include bone loss, muscle atrophy, sensory-motor deconditioning, and cardiovascular alteration, which may lead to orthostatic intolerance when astronauts return to Earth. Artificial gravity could provide a comprehensive countermeasure capable of challenging all the physiological systems at once, particularly if combined with exercise, thereby maintaining overall health during extended exposure to weightlessness. A new Compact Radius Centrifuge (CRC) platform was designed and built on the existing Short Radius Centrifuge (SRC) at the Massachusetts Institute of Technology (MIT). The centrifuge has been constrained to a radius of 1.4 m, the upper radial limit for a centrifuge to fit within an International Space Station (ISS) module without extensive structural alterations. In addition, a cycle ergometer has been added for exercise during centrifugation. The CRC now includes sensors of foot forces, cardiovascular parameters, and leg muscle electromyography. An initial human experiment was conducted on 12 subjects to analyze the effects of different artificial gravity levels (0 g, 1 g, and 1.4 g, measured at the feet) and ergometer exercise intensities (25 W warm-up, 50 W moderate and 100 W vigorous) on the musculoskeletal function as well as motion sickness and comfort. Foot forces were measured during the centrifuge runs, and subjective comfort and motion sickness data were gathered after each session. Preliminary results indicate that ergometer exercise on a centrifuge may be effective in improving musculoskeletal function. The combination is well tolerated and motion sickness is minimal. The MIT CRC is a novel platform for future studies of exercise combined with artificial gravity. This combination may be effective as a countermeasure to space physiological deconditioning.
Don't rock the boat: how antiphase crew coordination affects rowing.
de Brouwer, Anouk J; de Poel, Harjo J; Hofmijster, Mathijs J
2013-01-01
It is generally accepted that crew rowing requires perfect synchronization between the movements of the rowers. However, a long-standing and somewhat counterintuitive idea is that out-of-phase crew rowing might have benefits over in-phase (i.e., synchronous) rowing. In synchronous rowing, 5 to 6% of the power produced by the rower(s) is lost to velocity fluctuations of the shell within each rowing cycle. Theoretically, a possible way for crews to increase average boat velocity is to reduce these fluctuations by rowing in antiphase coordination, a strategy in which rowers perfectly alternate their movements. On the other hand, the framework of coordination dynamics explicates that antiphase coordination is less stable than in-phase coordination, which may impede performance gains. Therefore, we compared antiphase to in-phase crew rowing performance in an ergometer experiment. Nine pairs of rowers performed a two-minute maximum effort in-phase and antiphase trial at 36 strokes min(-1) on two coupled free-floating ergometers that allowed for power losses to velocity fluctuations. Rower and ergometer kinetics and kinematics were measured during the trials. All nine pairs easily acquired antiphase rowing during the warm-up, while one pair's coordination briefly switched to in-phase during the maximum effort trial. Although antiphase interpersonal coordination was indeed less accurate and more variable, power production was not negatively affected. Importantly, in antiphase rowing the decreased power loss to velocity fluctuations resulted in more useful power being transferred to the ergometer flywheels. These results imply that antiphase rowing may indeed improve performance, even without any experience with antiphase technique. Furthermore, it demonstrates that although perfectly synchronous coordination may be the most stable, it is not necessarily equated with the most efficient or optimal performance.
NASA Technical Reports Server (NTRS)
Figueroa, Fernando
1994-01-01
A complete description of an instrumented ergometer system, including the sensors, the data acquisition system, and the methodologies to calculate the kinematic parameters were initially developed at Tulane University. This work was continued by the PI at NASA Johnson Space Center, where a flight ergometer was instrumented and tested during a KC-135 Zero-Gravity flight. The sensors that form part of the system include EMG probes and accelerometers mounted on the subject using the ergometer, load cells to measure pedal forces, and encoders to measure position and orientation of the pedal (foot). Currently, data from the flight test is being analyzed and processed to calculate the kinematic parameters of the individual. The formulation developed during the initial months of the grant will be used for this purpose. The system's components are compact (all sensors are very small). A salient feature of the system and associated methodology to determine the kinematics is that although it uses accelerometers, position is not determined by integration. Position is determined by determining the angle of two frames of reference for which acceleration at one point is known in coordinates of both frames.
Roy, Susmita; Alves-Pinto, Ana; Lampe, Renée
2018-01-01
Cycling on ergometer is often part of rehabilitation programs for patients with cerebral palsy (CP). The present study analyzed activity patterns of individual lower leg muscle during active cycling on ergometer in patients with CP and compared them to similar recordings in healthy participants. Electromyographic (EMG) recordings of lower leg muscle activity were collected from 14 adult patients and 10 adult healthy participants. Activity of the following muscles was recorded: Musculus tibialis anterior, Musculus gastrocnemius, Musculus rectus femoris, and Musculus biceps femoris. Besides qualitative analysis also quantitative analysis of individual muscle activity was performed by computing the coefficient of variation of EMG signal amplitude. More irregular EMG patterns were observed in patients in comparison to healthy participants: agonist-antagonist cocontractions were more frequent, muscle activity measured at specific points of the cycle path was more variable, and dynamic range of muscle activity along the cycle path was narrower in patients. Hypertonicity was also more frequent in patients. Muscle activity patterns during cycling differed substantially across patients. It showed irregular nature and occasional sharp high peaks. Dynamic range was also narrower than in controls. Observations underline the need for individualized cycling training to optimize rehabilitation effects.
Zinner, Christoph; Sperlich, Billy; Born, Dennis-Peter; Michels, Guido
2017-01-01
The purpose of this study was to investigate the effects of combined arm and leg high-intensity low-volume interval training (HIITarm+leg) on maximal oxygen uptake, myocardial measures (i.e. stroke volume, cardiac output, ejection fraction), Tissue Oxygenation Index (TOI) of the vastus lateralis and triceps brachii, as well as power output in comparison to leg HIIT (HIITleg) only. The 20 healthy, male and female volunteers completed six sessions of either HIITleg on a cycle ergometer or HIITarm+leg on an arm and leg cycle ergometer. During pre- and post-testing, the volunteers completed a submaximal and incremental test to exhaustion on a cycle ergometer. Magnitude based interference revealed likely to very likely beneficial effects for HIITarm+leg compared to HIITleg in maximal oxygen uptake, cardiac measures as well peak power output. The TOI following HIITarm+leg demonstrated likely to very likely increased oxygenation in the triceps brachii or the vastus lateralis when compared to HIITleg. The results suggest that six sessions of HIITarm+leg may likely to very likely improve maximal oxygen uptake, some inotropy-related cardiac measures with improved tissue oxygenation of the triceps brachii and vastus lateralis muscles resulting in greater leg peak power output.
2013-01-01
Background The aim of this study was to investigate the influences of rehydration and food consumption on salivary flow, pH, and buffering capacity during bicycle ergometer exercise in participants. Methods Ten healthy volunteers exercised on a bicycle ergometer at 80% of their maximal heart rate. These sessions lasted for two periods of 20 min separated by 5-min rest intervals. Volunteers were subjected to one of the following conditions: (1) no water (mineral water) or food consumption, (2) only water for rehydration, (3) water and food consumption, (4) a sports drink only for rehydration, and (5) rehydration with a sports drink and food. Statistical significance was assessed using one-way analysis of variance and Dunnett’s test (p < 0.05). Results The salivary pH decreased significantly during and after exercise in conditions 4 and 5. The salivary buffering capacity decreased significantly during exercise and/or after the exercise in conditions 1, 3, 4, and 5. Conclusions The results showed that salivary pH and buffering capacity decreased greatly depending on the combination of a sports drink and food. PMID:24160307
Hadronic light-by-light scattering contribution to the muon g - 2 on the lattice
NASA Astrophysics Data System (ADS)
Asmussen, Nils; Gérardin, Antoine; Green, Jeremy; Gryniuk, Oleksii; von Hippel, Georg; Meyer, Harvey B.; Nyffeler, Andreas; Pascalutsa, Vladimir; Wittig, Hartmut
2018-05-01
We briefly review several activities at Mainz related to hadronic light-by-light scattering (HLbL) using lattice QCD. First we present a position-space approach to the HLbL contribution in the muon g̅2, where we focus on exploratory studies of the pion-pole contribution in a simple model and the lepton loop in QED in the continuum and in infinite volume. The second part describes a lattice calculation of the double-virtual pion transition form factor Fπ0γ*γ* (q21; q21) in the spacelike region with photon virtualities up to 1.5 GeV2 which paves the way for a lattice calculation of the pion-pole contribution to HLbL. The third topic involves HLbL forward scattering amplitudes calculated in lattice QCD which can be described, using dispersion relations (HLbL sum rules), by γ*γ* → hadrons fusion cross sections and then compared with phenomenological models.
Design Considerations of a Transverse Flux Machine for Direct-Drive Wind Turbine Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz
This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The proposed TFM has a modular structure with quasi-U stator cores and toroidal ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating setup to achieve high air gap flux density. Pole number selection is critical in the design process of a TFM as it affects both the torque density and power factor under fixed magnetic and changing electrical loading. Several key design ratios are introduced to facilitate the initial design procedure. The effect of pole shaping on back-EMF andmore » inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis (FEA). A proof-of-concept prototype was developed to experimentally validate the FEA results.« less
Design Considerations of a Transverse Flux Machine for Direct-Drive Wind Turbine Applications
Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz; ...
2018-03-12
This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The proposed TFM has a modular structure with quasi-U stator cores and toroidal ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating setup to achieve high air gap flux density. Pole number selection is critical in the design process of a TFM as it affects both the torque density and power factor under fixed magnetic and changing electrical loading. Several key design ratios are introduced to facilitate the initial design procedure. The effect of pole shaping on back-EMF andmore » inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis (FEA). A proof-of-concept prototype was developed to experimentally validate the FEA results.« less
A Novel Unit Cell for Active Switches in the Millimeter-Wave Frequency Range
NASA Astrophysics Data System (ADS)
Müller, Daniel; Scherer, Gunnar; Lewark, Ulrich J.; Massler, Hermann; Wagner, Sandrine; Tessmann, Axel; Leuther, Arnulf; Zwick, Thomas; Kallfass, Ingmar
2018-02-01
This paper presents a novel transistor unit cell which is intended to realize compact active switches in the high millimeter-wave frequency range. The unit cell consists of the combination of shunt and common gate transistor within a four-finger transistor cell, achieving gain in the amplifying state as well as good isolation in the isolating state. Gate width-dependent characteristics of the unit cell as well as the design of actual switch implementations are discussed in detail. To verify the concept, two switches, a single pole double throw (SPDT) switch and single pole quadruple throw (SP4T) switch, intended for the WR3 frequency range (220-325 GHz) were manufactured and characterized. The measured gain at 250 GHz is 4.6 and 2.2 dB for the SPDT and SP4T switch, respectively. An isolation of more than 24 dB for the SPDT switch and 12.8 dB for the SP4T switch was achieved.
Levy, Tal J; Rabani, Eran
2013-04-28
We study steady state transport through a double quantum dot array using the equation-of-motion approach to the nonequilibrium Green functions formalism. This popular technique relies on uncontrolled approximations to obtain a closure for a hierarchy of equations; however, its accuracy is questioned. We focus on 4 different closures, 2 of which were previously proposed in the context of the single quantum dot system (Anderson impurity model) and were extended to the double quantum dot array, and develop 2 new closures. Results for the differential conductance are compared to those attained by a master equation approach known to be accurate for weak system-leads couplings and high temperatures. While all 4 closures provide an accurate description of the Coulomb blockade and other transport properties in the single quantum dot case, they differ in the case of the double quantum dot array, where only one of the developed closures provides satisfactory results. This is rationalized by comparing the poles of the Green functions to the exact many-particle energy differences for the isolate system. Our analysis provides means to extend the equation-of-motion technique to more elaborate models of large bridge systems with strong electronic interactions.
Guitton, Anne-Elisabeth; Page, Damian R; Chambrier, Pierre; Lionnet, Claire; Faure, Jean-Emmanuel; Grossniklaus, Ueli; Berger, Frédéric
2004-06-01
In higher plants, double fertilisation initiates seed development. One sperm cell fuses with the egg cell and gives rise to the embryo, the second sperm cell fuses with the central cell and gives rise to the endosperm. The endosperm develops as a syncytium with the gradual organisation of domains along an anteroposterior axis defined by the position of the embryo at the anterior pole and by the attachment to the placenta at the posterior pole. We report that ontogenesis of the posterior pole in Arabidopsis thaliana involves oriented migration of nuclei in the syncytium. We show that this migration is impaired in mutants of the three founding members of the FERTILIZATION INDEPENDENT SEED (FIS) class, MEDEA (MEA), FIS2 and FERTILIZATION INDEPENDENT ENDOSPERM (FIE). A screen based on a green fluorescent protein (GFP) reporter line allowed us to identify two new loci in the FIS pathway, medicis and borgia. We have cloned the MEDICIS gene and show that it encodes the Arabidopsis homologue of the yeast WD40 domain protein MULTICOPY SUPRESSOR OF IRA (MSI1). The mutations at the new fis loci cause the same cellular defects in endosperm development as other fis mutations, including parthenogenetic development, absence of cellularisation, ectopic development of posterior structures and overexpression of the GFP marker.
NASA Astrophysics Data System (ADS)
Chabot, Nancy L.; Shread, Evangela E.; Harmon, John K.
2018-02-01
There is strong evidence that Mercury's polar deposits are water ice hosted in permanently shadowed regions. In this study, we present new Arecibo radar observations of Mercury's south pole, which reveal numerous radar-bright deposits and substantially increase the radar imaging coverage. We also use images from MESSENGER's full mission to determine the illumination conditions of Mercury's south polar region at the same spatial resolution as the north polar region, enabling comparisons between the two poles. The area of radar-bright deposits in Mercury's south is roughly double that found in the north, consistent with the larger permanently shadowed area in the older, cratered terrain at the south relative to the younger smooth plains at the north. Radar-bright features are strongly associated with regions of permanent shadow at both poles, consistent with water ice being the dominant component of the deposits. However, both of Mercury's polar regions show that roughly 50% of permanently shadowed regions lack radar-bright deposits, despite some of these locations having thermal environments that are conducive to the presence of water ice. The observed uneven distribution of water ice among Mercury's polar cold traps may suggest that the source of Mercury's water ice was not a steady, regular process but rather that the source was an episodic event, such as a recent, large impact on the innermost planet.
High-efficiency frequency doubling of continuous-wave laser light.
Ast, Stefan; Nia, Ramon Moghadas; Schönbeck, Axel; Lastzka, Nico; Steinlechner, Jessica; Eberle, Tobias; Mehmet, Moritz; Steinlechner, Sebastian; Schnabel, Roman
2011-09-01
We report on the observation of high-efficiency frequency doubling of 1550 nm continuous-wave laser light in a nonlinear cavity containing a periodically poled potassium titanyl phosphate crystal (PPKTP). The fundamental field had a power of 1.10 W and was converted into 1.05 W at 775 nm, yielding a total external conversion efficiency of 95±1%. The latter value is based on the measured depletion of the fundamental field being consistent with the absolute values derived from numerical simulations. According to our model, the conversion efficiency achieved was limited by the nonperfect mode matching into the nonlinear cavity and by the nonperfect impedance matching for the maximum input power available. Our result shows that cavity-assisted frequency conversion based on PPKTP is well suited for low-decoherence frequency conversion of quantum states of light.
Geometrical constraint on the localization of deep water formation
NASA Astrophysics Data System (ADS)
Ferreira, D.; Marshall, J.
2008-12-01
That deep water formation occurs in the North Atlantic and not North Pacific is one of the most notable features of the present climate. In an effort to build a system able to mimic such basic aspects of climate using a minimal description, we study here the influence of ocean geometry on the localization of deep water formation. Using the MIT GCM, two idealized configurations of an ocean-atmosphere-sea ice climate system are studied: Drake and Double-Drake. In Drake, one narrow barrier extends from the North Pole to 35°S while, in Double-Drake, two such barriers set 90° apart join at the North Pole to delimit a Small and a Large basin. Despite the different continental configurations, the two climates are strikingly similar in the zonal average (almost identical heat and fresh water transports, and meridional overturning circulation). However, regional circulations in the Small and Large basins exhibit distinctive Atlantic-like and Pacific-like characteristics: the Small basin is warmer and saltier than the Large one, concentrates dense water formation and deep overturning circulation and achieve the largest fraction of the northward ocean heat transport. We show that the warmer temperature and higher evaporation over the Small basin is not its distinguishing factor. Rather, it is the width of the basin in relation to the zonal fetch of the precipitation pattern. This generates a deficit/excess of precipitation over the Small/Large basin: a fraction of the moisture evaporated from the Small basin is transported zonally and rains out over the Large basin. This creates a salt contrast between the 2 basins, leading to the localization of deep convection in the salty Small basin. Finally, given on the broad similarities between the Double-Drake and real World, we suggest that many gross features that define the present climate are a consequence of 2 asymmetries: a meridional asymmetry (a zonally unblocked southern/blocked northern ocean) and a zonal one (a small and a large basin in the northern hemisphere).
Van der Loos, H F Machiel; Worthen-Chaudhari, Lise; Schwandt, Douglas; Bevly, David M; Kautz, Steven A
2010-08-01
This paper presents a novel computer-controlled bicycle ergometer, the TiltCycle, for use in human biomechanics studies of locomotion. The TiltCycle has a tilting (reclining) seat and backboard, a split pedal crankshaft to isolate the left and right loads to the feet of the pedaler, and two belt-driven, computer-controlled motors to provide assistance or resistance loads independently to each crank. Sensors measure the kinematics and force production of the legs to calculate work performed, and the system allows for goniometric and electromyography signals to be recorded. The technical description presented includes the mechanical design, low-level software and control algorithms, system identification and validation test results.
Somatotype-variables related to muscle torque and power output in female volleyball players.
Buśko, Krzysztof; Lewandowska, Joanna; Lipińska, Monika; Michalski, Radosław; Pastuszak, Anna
2013-01-01
The purpose of this study was to investigate the relationship between somatotype, muscle torque, maximal power output and height of rise of the body mass centre measured in akimbo counter movement jump (ACMJ), counter movement jump (CMJ) and spike jump (SPJ), and power output measured in maximal cycle ergometer exercise bouts in female volleyball players. Fourteen players participated in the study. Somatotype was determined using the Heath-Carter method. Maximal muscle torque was measured under static conditions. Power output was measured in 5 maximal cycle ergometer exercise bouts, 10 s each, at increasing external loads equal to 2.5, 5.0, 7.5, 10.0 and 12.5% of body weight (BW). All jump trials (ACMJ, SPJ and CMJ) were performed on a force plate. The mean somatotype of volleyball players was: 4.9-3.5-2.5. The value of the sum of muscle torque of the left upper extremities was significantly correlated only with mesomorphic component. Mesomorphic and ectomorphic components correlated significantly with values of maximal power measured during ACMJ and CMJ. Power output measured in maximal cycle ergometer exercise bouts at increasing external loads equal to 2.5, 5.0 and 7.5% of BW was significantly correlated with endomorphy, mesomorphy and ectomorphy.
Comolli, Lorenzo; Ferrante, Simona; Pedrocchi, Alessandra; Bocciolone, Marco; Ferrigno, Giancarlo; Molteni, Franco
2010-05-01
Functional electrical stimulation (FES) is a well established method in the rehabilitation of stroke patients. Indeed, a bilateral movement such as cycling induced by FES would be crucial for these patients who had an unilateral motor impairment and had to recover an equivalent use of limbs. The aim of this study was to develop a low-cost meteorologically qualified cycle-ergometer, optimized for patients with stroke. A commercial ergometer was instrumented with resistive strain gauges and was able to provide the torque produced at the right and left crank, independently. The developed system was integrated with a stimulator, obtaining a novel FES cycling device able to control in real-time the movement unbalance. A dynamic calibration of the sensors was performed and a total torque uncertainty was computed. The system was tested on a healthy subject and on a stroke patient. Results demonstrated that the proposed sensors could be successfully used during FES cycling sessions where the maximum torque produced is about 9Nm, an order of magnitude less than the torque produced during voluntary cycling. This FES cycling system will assist in future investigations on stroke rehabilitation by means of FES and in new exercise regimes designed specifically for patients with unilateral impairments.
Power output measurement during treadmill cycling.
Coleman, D A; Wiles, J D; Davison, R C R; Smith, M F; Swaine, I L
2007-06-01
The study aim was to consider the use of a motorised treadmill as a cycling ergometry system by assessing predicted and recorded power output values during treadmill cycling. Fourteen male cyclists completed repeated cycling trials on a motorised treadmill whilst riding their own bicycle fitted with a mobile ergometer. The speed, gradient and loading via an external pulley system were recorded during 20-s constant speed trials and used to estimate power output with an assumption about the contribution of rolling resistance. These values were then compared with mobile ergometer measurements. To assess the reliability of measured power output values, four repeated trials were conducted on each cyclist. During level cycling, the recorded power output was 257.2 +/- 99.3 W compared to the predicted power output of 258.2 +/- 99.9 W (p > 0.05). For graded cycling, there was no significant difference between measured and predicted power output, 268.8 +/- 109.8 W vs. 270.1 +/- 111.7 W, p > 0.05, SEE 1.2 %. The coefficient of variation for mobile ergometer power output measurements during repeated trials ranged from 1.5 % (95 % CI 1.2 - 2.0 %) to 1.8 % (95 % CI 1.5 - 2.4 %). These results indicate that treadmill cycling can be used as an ergometry system to assess power output in cyclists with acceptable accuracy.
Incremental exercise test for the evaluation of peak oxygen consumption in paralympic swimmers.
de Souza, Helton; DA Silva Alves, Eduardo; Ortega, Luciana; Silva, Andressa; Esteves, Andrea M; Schwingel, Paulo A; Vital, Roberto; DA Rocha, Edilson A; Rodrigues, Bruno; Lira, Fabio S; Tufik, Sergio; DE Mello, Marco T
2016-04-01
Peak oxygen consumption (VO2peak) is a fundamental parameter used to evaluate physical capacity. The objective of this study was to explore two types of incremental exercise tests used to determine VO2peak in four Paralympic swimmers: arm ergometer testing in the laboratory and testing in the swimming pool. On two different days, the VO2peak values of the four athletes were measured in a swimming pool and by a cycle ergometer. The protocols identified the VO2peak by progressive loading until the volitional exhaustion maximum was reached. The results were analyzed using the paired Student's t-test, Cohen's d effect sizes and a linear regression. The results showed that the VO2peak values obtained using the swimming pool protocol were higher (P=0.02) than those obtained by the arm ergometer (45.8±19.2 vs. 30.4±15.5; P=0.02), with a large effect size (d=3.20). When analyzing swimmers 1, 2, 3 and 4 individually, differences of 22.4%, 33.8%, 60.1% and 27.1% were observed, respectively. Field tests similar to the competitive setting are a more accurate way to determine the aerobic capacity of Paralympic swimmers. This approach provides more sensitive data that enable better direction of training, consequently facilitating improved performance.
Effects of Beetroot Juice Supplementation on a 30-s High-Intensity Inertial Cycle Ergometer Test
Domínguez, Raul; Garnacho-Castaño, Manuel Vicente; Cuenca, Eduardo; García-Fernández, Pablo; Muñoz-González, Arturo; de Jesús, Fernando; Lozano-Estevan, María Del Carmen; Veiga-Herreros, Pablo
2017-01-01
Background: Beetroot juice (BJ) is rich in inorganic nitrates and has proved effective at increasing blood nitric oxide (NO) levels. When used as a supplement BJ has shown an ergogenic effect on cardiorespiratory resistance exercise modalities, yet few studies have examined its impact on high intensity efforts. Objective: To assess the effects of BJ intake on anaerobic performance in a Wingate test. Methods: Fifteen trained men (age 21.46 ± 1.72 years, height 1.78 ± 0.07 cm and weight 76.90 ± 8.67 kg) undertook a 30-s maximum intensity test on an inertial cycle ergometer after drinking 70 mL of BJ (5.6 mmol NO3−) or placebo. Results: Despite no impacts of BJ on the mean power recorded during the test, improvements were produced in peak power (6%) (p = 0.034), average power 0–15 s (6.7%) (p = 0.048) and final blood lactate levels (82.6%) (p < 0.001), and there was a trend towards a shorter time taken to attain peak power (−8.4%) (p = 0.055). Conclusions: Supplementation with BJ has an ergonomic effect on maximum power output and on average power during the first 15 s of a 30-s maximum intensity inertial cycle ergometer test. PMID:29244746
Personal customizing exercise with a wearable measurement and control unit.
Wang, Zhihui; Kiryu, Tohru; Tamura, Naoki
2005-06-28
Recently, wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of customizing machine-based exercise on an individual basis by relying on biosignal-based controls. We propose a new wearable unit design equipped with measurement and control functions to support the customization process. The wearable unit can measure the heart rate and electromyogram signals during exercise performance and output workload control commands to the exercise machines. The workload is continuously tracked with exercise programs set according to personally customized workload patterns and estimation results from the measured biosignals by a fuzzy control method. Exercise programs are adapted by relying on a computer workstation, which communicates with the wearable unit via wireless connections. A prototype of the wearable unit was tested together with an Internet-based cycle ergometer system to demonstrate that it is possible to customize exercise on an individual basis. We tested the wearable unit in nine people to assess its suitability to control cycle ergometer exercise. The results confirmed that the unit could successfully control the ergometer workload and continuously support gradual changes in physical activities. The design of wearable units equipped with measurement and control functions is an important step towards establishing a convenient and continuously supported wellness environment.
Accuracy of the Velotron ergometer and SRM power meter.
Abbiss, C R; Quod, M J; Levin, G; Martin, D T; Laursen, P B
2009-02-01
The purpose of this study was to determine the accuracy of the Velotron cycle ergometer and the SRM power meter using a dynamic calibration rig over a range of exercise protocols commonly applied in laboratory settings. These trials included two sustained constant power trials (250 W and 414 W), two incremental power trials and three high-intensity interval power trials. To further compare the two systems, 15 subjects performed three dynamic 30 km performance time trials. The Velotron and SRM displayed accurate measurements of power during both constant power trials (<1% error). However, during high-intensity interval trials the Velotron and SRM were found to be less accurate (3.0%, CI=1.6-4.5% and -2.6%, CI=-3.2--2.0% error, respectively). During the dynamic 30 km time trials, power measured by the Velotron was 3.7+/-1.9% (CI=2.9-4.8%) greater than that measured by the SRM. In conclusion, the accuracy of the Velotron cycle ergometer and the SRM power meter appears to be dependent on the type of test being performed. Furthermore, as each power monitoring system measures power at various positions (i.e. bottom bracket vs. rear wheel), caution should be taken when comparing power across the two systems, particularly when power is variable.
Inertial effects on mechanically braked Wingate power calculations.
Reiser, R F; Broker, J P; Peterson, M L
2000-09-01
The standard procedure for determining subject power output from a 30-s Wingate test on a mechanically braked (friction-loaded) ergometer includes only the braking resistance and flywheel velocity in the computations. However, the inertial effects associated with accelerating and decelerating the crank and flywheel also require energy and, therefore, represent a component of the subject's power output. The present study was designed to determine the effects of drive-system inertia on power output calculations. Twenty-eight male recreational cyclists completed Wingate tests on a Monark 324E mechanically braked ergometer (resistance: 8.5% body mass (BM), starting cadence: 60 rpm). Power outputs were then compared using both standard (without inertial contribution) and corrected methods (with inertial contribution) of calculating power output. Relative 5-s peak power and 30-s average power for the corrected method (14.8 +/- 1.2 W x kg(-1) BM; 9.9 +/- 0.7 W x kg(-1) BM) were 20.3% and 3.1% greater than that of the standard method (12.3 +/- 0.7 W x kg(-1) BM; 9.6 +/- 0.7 W x kg(-1) BM), respectively. Relative 5-s minimum power for the corrected method (6.8 +/- 0.7 W x kg(-1) BM) was 6.8% less than that of the standard method (7.3 +/- 0.8 W x kg(-1) BM). The combined differences in the peak power and minimum power produced a fatigue index for the corrected method (54 +/- 5%) that was 31.7% greater than that of the standard method (41 +/- 6%). All parameter differences were significant (P < 0.01). The inertial contribution to power output was dominated by the flywheel; however, the contribution from the crank was evident. These results indicate that the inertial components of the ergometer drive system influence the power output characteristics, requiring care when computing, interpreting, and comparing Wingate results, particularly among different ergometer designs and test protocols.
Chan, Tuen Ching; Chan, Fei; Shea, Yat Fung; Lin, Oi Yee; Luk, James Ka Hay; Chan, Felix Hon Wai
2012-10-01
Rehabilitation using interactive virtual reality Wii (Wii-IVR) was shown to be feasible in patients with different medical problems, but there was no study examining its use in a geriatric day hospital (GDH). The aim of the present study was to test the feasibility, acceptability and efficacy of Wii-IVR in GDH. It was a clinical trial with matched historic controls. Patients of a GDH were recruited to participate in Wii-IVR by playing "Wii Fit". Participants used a Wii controller to carry out movements involved in an arm ergometer. Each participant received eight sessions of Wii-IVR in addition to conventional GDH rehabilitation. Feasibility was assessed by the total time receiving Wii-IVR, the percentage of maximal heart rate reserve (%MHR) and Borg perceived exertion scale (BS) after participating in Wii-IVR. %MHR and BS were compared with those after carrying out an arm ergometer for the same duration. Acceptability was assessed by an interviewer-administered questionnaire. Efficacy was assessed by comparing improvements in Functional Independence Measure (FIM) between participants and matched historic controls, who received conventional GDH rehabilitations only. A total of 30 patients completed the study. Participants completed a total of 1941 min of event-free Wii-IVR. The mean %MHR was 15.9% ± 9.9% and the mean BS was 7.9 ± 2.3. There was no significant difference in %MHR and BS between participating in Wii-IVR and arm ergometer. Most participants found Wii-IVR similar to the arm ergometer, and would like to continue Wii-IVR if they had Wii at home. Improvements in FIM of participants were significantly more than that of historic controls. Wii-IVR in GDH was feasible and most participants accepted it. Participants had more improvements in FIM. © 2012 Japan Geriatrics Society.
Maione, D; Cicero, A Fg; Bacchelli, S; Cosentino, E; Degli Esposti, D; Senaldi, R; Strocchi, E; D'Addato, S; Borghi, C
2013-01-01
We tested whether the known cytochrome c oxidase (COX) inhibition by nitric oxide (NO) could be quantified by VO(2) kinetics during constant load supra-Anaerobic Threshold (AT) exercises in healthy trained or untrained subjects following aerobic training or nitrate administration. In cycle ergometer constant load exercises supra-AT, identified in previous incremental tests, VO(2) kinetics describe a double exponential curve, one rapid and one appreciably slower, allowing the area between them to be calculate in O(2) l. After training, with increased NO availability, this area decreases in inverse ratio to treatment efficacy. In fact, in 11 healthy subjects after aerobic training for 6-7 weeks, area was decreased on average by 51 %. In 11 untrained subjects, following the assumption of an NO donor, 20 mg isosorbide 5 mononitrate, area was decreased on average by 53 %. In conclusion, supra-AT VO(2) kinetics in constant load exercises permit the quantification of the inhibitory effect NO-dependent on COX after either physical training or nitrate assumption.
A hybrid electro-optic polymer and TiO2 double-slot waveguide modulator
Qiu, Feng; Spring, Andrew M.; Maeda, Daisuke; Ozawa, Masa-aki; Odoi, Keisuke; Otomo, Akira; Aoki, Isao; Yokoyama, Shiyoshi
2015-01-01
An electro-optic (EO) modulator using a TiO2 slot hybrid waveguide has been designed and fabricated. Optical mode calculations revealed that the mode was primarily confined within the slots when using a double-slot configuration, thus achieving a high EO activity experimentally. The TiO2 slots also acted as an important barrier to induce an enhanced DC field during the poling of the EO polymer and the driving of the EO modulator. The hybrid phase modulator exhibited a driving voltage (Vπ) of 1.6 V at 1550 nm, which can be further reduced to 0.8 V in a 1 cm-long push-pull Mach–Zehnder interferometer (MZI) structure. The modulator demonstrated a low propagation loss of 5 dB/cm and a relatively high end-fire coupling efficiency. PMID:25708425
Srivastava, Viranjay M
2015-01-01
In the present technological expansion, the radio frequency integrated circuits in the wireless communication technologies became useful because of the replacement of increasing number of functions, traditional hardware components by modern digital signal processing. The carrier frequencies used for communication systems, now a day, shifted toward the microwave regime. The signal processing for the multiple inputs multiple output wireless communication system using the Metal- Oxide-Semiconductor Field-Effect-Transistor (MOSFET) has been done a lot. In this research the signal processing with help of nano-scaled Cylindrical Surrounding Double Gate (CSDG) MOSFET by means of Double- Pole Four-Throw Radio-Frequency (DP4T RF) switch, in terms of Insertion loss, Isolation, Reverse isolation and Inter modulation have been analyzed. In addition to this a channel model has been presented. Here, we also discussed some patents relevant to the topic.
Khripunov, Sergey; Kobtsev, Sergey; Radnatarov, Daba
2016-01-20
This work presents for the first time to the best of our knowledge a comparative efficiency analysis among various techniques of extra-cavity second harmonic generation (SHG) of continuous-wave single-frequency radiation in nonperiodically poled nonlinear crystals within a broad range of power levels. Efficiency of nonlinear radiation transformation at powers from 1 W to 10 kW was studied in three different configurations: with an external power-enhancement cavity and without the cavity in the case of single and double radiation pass through a nonlinear crystal. It is demonstrated that at power levels exceeding 1 kW, the efficiencies of methods with and without external power-enhancement cavities become comparable, whereas at even higher powers, SHG by a single or double pass through a nonlinear crystal becomes preferable because of the relatively high efficiency of nonlinear transformation and fairly simple implementation.
Dummy left behind by Skylab 3 crew for the Skylab 4 crew
NASA Technical Reports Server (NTRS)
1973-01-01
This photograph is an illustration of the humorous side of the Skylab 3 crew. This dummy was left behind in the Skylab space station by the Skylab 3 crew to be found by the Skylab 4 crew. The dummy is dressed in a flight suit and placed in the Lower Body Negative Pressure Device. The name tag indicates that it represents Gerald P. Carr, Skylab 4 commander. In the background is a partial view of the dummy for William R. Pogue, Skylab 4 pilot, propped upon the bicycle ergometer (1586); This dummy is dressed in a flight suit and propped upon the bicycle ergometer. The name tag indicates that it represents William R. Pogue, Skylab 4 pilot (1587).
A cytogenetic method for stacking gene pairs in common wheat.
Thomas, J; Riedel, E; Benabdelmouna, A; Armstrong, K
2004-10-01
The potential for non-reciprocal Robertsonian translocations of wheat (Triticum aestivum L.) to assist in the stacking of genes was assessed from a study of their cytological and genetic behaviour. To obtain translocations, a double monosomic (3B+5A; 2n=40=19ii+2i) was crossed reciprocally with a contrasting disomic. Individuals inheriting a broken monosome were identified from the loss of one arm-specific DNA marker coupled with retention of a marker for the opposite arm. No double breaks (potential translocations) were found in 180 cross progeny recovered from pollen of the double monosomic but two instances (loss of 5AL plus 3BS; loss of 5AL plus 3BL) were found in 251 progeny recovered from ovules. Meiotic pairing and multi-color genome-specific fluorescence in situ hybridization (mcGISH) showed that each plant with a double break contained one translocated chromosome between the A and B genomes that had rejoined at the centromere and that formed a trivalent (19ii+ liii) in about 83% of PMC. Most trivalents (approximately 92%) aligned at metaphase in a 'V' configuration(alternate disjunction) while the rest aligned in linear 'I'(adjacent disjunction) or ambiguous 'L' configurations. Genetic analysis of a testcross of these 'fusion monosomics' showed that this preferential co-orientation of the trivalent influenced the assortment of the chromosome arms involved. Loci that were located in the hemizygous ends of the 'V' trivalent showed strong quasi-linkage in that most ovules from the female testcross carried relevant DNA markers either from both standard chromosomes or from neither. This shows that, in most cases, the two standard chromosomes assorted to the same pole while the fused monosome segregated to the opposite pole. For heterozygous loci (present both on the fusion monosome and the standard chromosomes) assortment was either independent or showed partial linkage to the hemizygous arm depending on the reported recombination distance from centromere. Marker assortment was further distorted in male testcrosses and in doubled haploids (made from the fusion monosomics by the maize method) by the strong selective advantage of pollen or haploids that inherited the standard chromosomes rather than the deficiencies. This genetic data shows that under the combined influence of alternate disjunction and natural selection, progeny of fusion monosomics will revert to the standard disomic arrangement, fixing the gene content of both hemizygous arms in the process. Thus, any pair of genes could be targeted for joint fixation by isolating the fusion monosome that will link them temporarily in a segregating population.
Chabot, Nancy L.; Shread, Evangela E.; Harmon, John K.
2018-01-01
There is strong evidence that Mercury’s polar deposits are water ice hosted in permanently shadowed regions. In this study, we present new Arecibo radar observations of Mercury’s south pole, which reveal numerous radar-bright deposits and substantially increase the radar imaging coverage. We also use images from MESSENGER’s full mission to determine the illumination conditions of Mercury’s south polar region at the same spatial resolution as the north polar region, enabling comparisons between the two poles. The area of radar-bright deposits in Mercury’s south is roughly double that found in the north, consistent with the larger permanently shadowed area in the older, cratered terrain at the south relative to the younger smooth plains at the north. Radar-bright features are strongly associated with regions of permanent shadow at both poles, consistent with water ice being the dominant component of the deposits. However, both of Mercury’s polar regions show that roughly 50% of permanently shadowed regions lack radar-bright deposits, despite some of these locations having thermal environments that are conducive to the presence of water ice. The observed uneven distribution of water ice among Mercury’s polar cold traps may suggest that the source of Mercury’s water ice was not a steady, regular process but rather that the source was an episodic event, such as a recent, large impact on the innermost planet. PMID:29552436
The cell pole: the site of cross talk between the DNA uptake and genetic recombination machinery.
Kidane, Dawit; Ayora, Silvia; Sweasy, Joann B; Graumann, Peter L; Alonso, Juan C
2012-01-01
Natural transformation is a programmed mechanism characterized by binding of free double-stranded (ds) DNA from the environment to the cell pole in rod-shaped bacteria. In Bacillus subtilis some competence proteins, which process the dsDNA and translocate single-stranded (ss) DNA into the cytosol, recruit a set of recombination proteins mainly to one of the cell poles. A subset of single-stranded binding proteins, working as "guardians", protects ssDNA from degradation and limit the RecA recombinase loading. Then, the "mediators" overcome the inhibitory role of guardians, and recruit RecA onto ssDNA. A RecA·ssDNA filament searches for homology on the chromosome and, in a process that is controlled by "modulators", catalyzes strand invasion with the generation of a displacement loop (D-loop). A D-loop resolvase or "resolver" cleaves this intermediate, limited DNA replication restores missing information and a DNA ligase seals the DNA ends. However, if any step fails, the "rescuers" will repair the broken end to rescue chromosomal transformation. If the ssDNA does not share homology with resident DNA, but it contains information for autonomous replication, guardian and mediator proteins catalyze plasmid establishment after inhibition of RecA. DNA replication and ligation reconstitute the molecule (plasmid transformation). In this review, the interacting network that leads to a cross talk between proteins of the uptake and genetic recombination machinery will be placed into prospective.
The cell pole: The site of cross talk between the DNA uptake and genetic recombination machinery
Kidane, Dawit; Ayora, Silvia; Sweasy, Joann; Graumann, Peter L.; Alonso, Juan C.
2012-01-01
Natural transformation is a programmed mechanism characterized by binding of free double-stranded (ds) DNA from the environment to the cell pole in rod-shaped bacteria. In Bacillus subtilis some competence proteins, which process the dsDNA and translocate single-stranded (ss) DNA into the cytosol, recruit a set of recombination proteins mainly to one of the cell poles. A subset of single-stranded binding proteins, working as “guardians”, protect ssDNA from degradation and limit the RecA recombinase loading. Then, the “mediators” overcome the inhibitory role of guardians, and recruit RecA onto ssDNA. A RecA·ssDNA filament searches for homology on the chromosome and, in a process that is controlled by “modulators”, catalyzes strand invasion with the generation of a displacement loop (D-loop). A D-loop resolvase or “resolver” cleaves this intermediate, limited DNA replication restores missing information and a DNA ligase seals the DNA ends. However, if any step fails, the “rescuers” will repair the broken end to rescue chromosomal transformation. If the ssDNA does not share homology with resident DNA, but it contains information for autonomous replication, guardian and mediator proteins catalyze plasmid establishment after inhibition of RecA. DNA replication and ligation reconstitute the molecule (plasmid transformation). In this review, the interacting network that leads to a cross talk between proteins of the uptake and genetic recombination machinery will be placed into prospective. PMID:23046409
Efficient 525 nm laser generation in single or double resonant cavity
NASA Astrophysics Data System (ADS)
Liu, Shilong; Han, Zhenhai; Liu, Shikai; Li, Yinhai; Zhou, Zhiyuan; Shi, Baosen
2018-03-01
This paper reports the results of a study into highly efficient sum frequency generation from 792 and 1556 nm wavelength light to 525 nm wavelength light using either a single or double resonant ring cavity based on a periodically poled potassium titanyl phosphate crystal (PPKTP). By optimizing the cavity's parameters, the maximum power achieved for the resultant 525 nm laser was 263 and 373 mW for the single and double resonant cavity, respectively. The corresponding quantum conversion efficiencies were 8 and 77% for converting 1556 nm photons to 525 nm photons with the single and double resonant cavity, respectively. The measured intra-cavity single pass conversion efficiency for both configurations was about 5%. The performances of the sum frequency generation in these two configurations was studied and compared in detail. This work will provide guidelines for optimizing the generation of sum frequency generated laser light for a variety of configurations. The high conversion efficiency achieved in this work will help pave the way for frequency up-conversion of non-classical quantum states, such as the squeezed vacuum and single photon states. The proposed green laser source will be used in our future experiments, which includes a plan to generate two-color entangled photon pairs and achieve the frequency down-conversion of single photons carrying orbital angular momentum.
Double-β decay matrix elements from lattice quantum chromodynamics
NASA Astrophysics Data System (ADS)
Tiburzi, Brian C.; Wagman, Michael L.; Winter, Frank; Chang, Emmanuel; Davoudi, Zohreh; Detmold, William; Orginos, Kostas; Savage, Martin J.; Shanahan, Phiala E.; Nplqcd Collaboration
2017-09-01
A lattice quantum chromodynamics (LQCD) calculation of the nuclear matrix element relevant to the n n →p p e e ν¯eν¯e transition is described in detail, expanding on the results presented in Ref. [P. E. Shanahan et al., Phys. Rev. Lett. 119, 062003 (2017), 10.1103/PhysRevLett.119.062003]. This matrix element, which involves two insertions of the weak axial current, is an important input for phenomenological determinations of double-β decay rates of nuclei. From this exploratory study, performed using unphysical values of the quark masses, the long-distance deuteron-pole contribution to the matrix element is separated from shorter-distance hadronic contributions. This polarizability, which is only accessible in double-weak processes, cannot be constrained from single-β decay of nuclei, and is found to be smaller than the long-distance contributions in this calculation, but non-negligible. In this work, technical aspects of the LQCD calculations, and of the relevant formalism in the pionless effective field theory, are described. Further calculations of the isotensor axial polarizability, in particular near and at the physical values of the light-quark masses, are required for precise determinations of both two-neutrino and neutrinoless double-β decay rates in heavy nuclei.
NASA Astrophysics Data System (ADS)
Liu, L.; Wang, H. Y.; Ning, Y.; Shen, C.; Si, L.; Yang, Y.; Bao, Q. L.; Ren, G.
2017-05-01
A sub-nanosecond seeded optical parametric generator (OPG) based on magnesium oxide-doped periodically poled lithium niobate (MgO:PPLN) crystal is presented. Pumped by an actively Q-switched diode-pumped 1 kHz, 1064 nm, Nd:YAG microlaser and seeded with a low power distributed feedback (DFB) diode continuous-wave (CW) laser, the OPG generated an output energy of 41.4 µJ and 681 ps pulse duration for the signal at 1652.4 nm, achieving a quantum conversion efficiency of 61.2% and a slope efficiency of 41.8%. Signal tuning was achieved from 1651.0 to 1652.4 nm by tuning the seed-laser current. The FWHM of the signal spectrum was approximately from 35 nm to 0.5 nm by injection seed laser. The SHG doubled the frequency of OPG signal to produce a output energy of 12 µJ with the energy conversion efficiency of 29.0% and tunanble wavelength near 826 nm.
Determination of A FB b at the Z pole using inclusive charge reconstruction and lifetime tagging
NASA Astrophysics Data System (ADS)
DELPHI Collaboration
2005-03-01
A novel high precision method measures the b-quark forward-backward asymmetry at the Z pole on a sample of 3,560,890 hadronic events collected with the DELPHI detector in 1992 to 2000. An enhanced impact parameter tag provides a high purity b sample. For event hemispheres with a reconstructed secondary vertex the charge of the corresponding quark or anti-quark is determined using a neural network which combines in an optimal way the full available charge information from the vertex charge, the jet charge and from identified leptons and hadrons. The probability of correctly identifying b-quarks and anti-quarks is measured on the data themselves comparing the rates of double hemisphere tagged like-sign and unlike-sign events. The b-quark forward-backward asymmetry is determined from the differential asymmetry, taking small corrections due to hemisphere correlations and background contributions into account. The results for different centre-of-mass energies are: A_{FB}^{{b}} (89.449 GeV) = 0.0637 ± 0.0143(stat.) ± 0.0017(syst.)
Waveguide Harmonic Generator for the SIM
NASA Technical Reports Server (NTRS)
Chang, Daniel; Poberezhskiy, Ilya; Mulder, Jerry
2008-01-01
A second-harmonic generator (SHG) serves as the source of the visible laser beam in an onboard calibration scheme for NASA's planned Space Interferometry Mission (SIM), which requires an infrared laser beam and a visible laser beam coherent with the infrared laser beam. The SHG includes quasi-phase-matched waveguides made of MgO-doped, periodically poled lithium niobate, pigtailed with polarization- maintaining optical fibers. Frequency doubling by use of such waveguides affords the required combination of coherence and sufficient conversion efficiency for the intended application. The spatial period of the poling is designed to obtain quasi-phase- matching at a nominal middle excitation wavelength of 1,319.28 nm. The SHG is designed to operate at a warm bias (ambient temperature between 20 and 25 C) that would be maintained in its cooler environment by use of electric heaters; the heater power would be adjusted to regulate the temperature precisely and thereby maintain the required precision of the spatial period. At the state of development at the time of this reporting, the SHG had been packaged and subjected to most of its planned space-qualification tests.
Zero and root loci of disturbed spring–mass systems
Lecomte, Christophe
2014-01-01
Models consisting of chains of particles that are coupled to their neighbours appear in many applications in physics or engineering, such as in the study of dynamics of mono-atomic and multi-atomic lattices, the resonances of crystals with impurities and the response of damaged bladed discs. Analytical properties of the dynamic responses of such disturbed chains of identical springs and masses are presented, including when damping is present. Several remarkable properties in the location of the resonances (poles) and anti-resonances (zeros) of the displacements in the frequency domain are presented and proved. In particular, it is shown that there exists an elliptical region in the frequency–disturbance magnitude plane from which zeros are excluded and the discrete values of the frequency and disturbance at which double poles occur are identified. A particular focus is on a local disturbance, such as when a spring or damper is modified at or between the first and last masses. It is demonstrated how, notably through normalization, the techniques and results of the paper apply to a broad category of more complex systems in physics, chemistry and engineering. PMID:24711724
Tauber, Volkmar; Wohlmuth, Martin; Hochmuth, Andreas; Schimetta, Wolfgang; Schimetta, Wofgang; Krause, F Steffen
2015-01-01
To evaluate the efficacy of flexible ureterscopy (fURS) and extracorporal shockwave lithotripsy (SWL) in the treatment of urolithiasis, complemented by a subgroup analysis of lower pole calyx. Retrospective analysis of patients treated by fURS or SWL was performed by independent variables such as gender, age, nephrolith size, double-J stent (DJ stent) and stone localisation. Out of 326 patients, 165 were treated by SWL and 161 by fURS. Complete stone removal was achieved by fURS in 83.2% and by SWL in 43.0% (p < 0.001). Asymptomatic behaviour (88-89%) and complication rate (10-11%) were nearly the same in both methods. A higher retreatment rate for SWL was necessary; otherwise, an auxillary DJ stent was performed more often preoperative before fURS. The subgroup analysis of lower pole calyx confirmed these evaluations. Complete stone-free removal was almost 8 times higher after fURS compared to SWL. The efficacy of fURS in treatment of urolithiasis is substantially higher than the efficacy of SWL. © 2015 S. Karger AG, Basel.
2008-02-18
S122-E-011207 (18 Feb. 2008) --- Astronaut Stanley Love, STS-122 mission specialist, looks over procedures checklists while occupying the bicycle ergometer on the middeck of the Space Shuttle Atlantis.
Ghost-free, finite, fourth-order D = 3 gravity.
Deser, S
2009-09-04
Canonical analysis of a recently proposed linear + quadratic curvature gravity model in D = 3 establishes its pure, irreducibly fourth derivative, quadratic curvature limit as both ghost-free and power-counting UV finite, thereby maximally violating standard folklore. This limit is representative of a generic class whose kinetic terms are conformally invariant in any dimension, but it is unique in simultaneously avoiding the transverse-traceless graviton ghosts plaguing D > 3 quadratic actions as well as double pole propagators in its other variables. While the two-term model is also unitary, its additional mode's second-derivative nature forfeits finiteness.
Large Electroweak Corrections to Vector-Boson Scattering at the Large Hadron Collider.
Biedermann, Benedikt; Denner, Ansgar; Pellen, Mathieu
2017-06-30
For the first time full next-to-leading-order electroweak corrections to off-shell vector-boson scattering are presented. The computation features the complete matrix elements, including all nonresonant and off-shell contributions, to the electroweak process pp→μ^{+}ν_{μ}e^{+}ν_{e}jj and is fully differential. We find surprisingly large corrections, reaching -16% for the fiducial cross section, as an intrinsic feature of the vector-boson-scattering processes. We elucidate the origin of these large electroweak corrections upon using the double-pole approximation and the effective vector-boson approximation along with leading-logarithmic corrections.
Effects of different modes of exercise on appetite and appetite-regulating hormones.
Kawano, Hiroshi; Mineta, Mayuko; Asaka, Meiko; Miyashita, Masashi; Numao, Shigeharu; Gando, Yuko; Ando, Takafumi; Sakamoto, Shizuo; Higuchi, Mitsuru
2013-07-01
The present study determined the changes in appetite and appetite-regulating gut hormones during and following bouts of both rope skipping exercise (weight-bearing) and bicycle ergometer exercise (non-weight-bearing). After a 12-h fast, 15 young men (mean ± SD, age 24.4 ± 1.7 yrs, maximal oxygen uptake 47.0 ± 6.5 mL/kg/min) participated in three 160 min trials: (1) rope skipping exercise (295 ± 40 kcal, 3 sets × 10 min with 5-min interval, then rested for 120 min); (2) bicycle ergometer exercise (288 ± 36 kcal, 3 sets × 10 min with 5-min interval, then rested for 120 min); (3) control (rested for 160 min). Ratings of perceived hunger and acylated ghrelin were suppressed and total peptide YY (PYY) were increased during and immediately after exercise in both exercise trials, but glucagon liked peptide-1 was not changed. Furthermore, suppressed hunger during rope skipping exercise was greater than that during bicycle ergometer exercise, but there were no differences in acylated ghrelin and total PYY. These results indicate that weight-bearing exercise has a greater exercise-induced appetite suppressive effect compared with non-weight-bearing exercise, and both forms of exercise lowered acylated ghrelin and increased total PYY, but the changes did not differ significantly between exercise modes. Copyright © 2013 Elsevier Ltd. All rights reserved.
Personal customizing exercise with a wearable measurement and control unit
Wang, Zhihui; Kiryu, Tohru; Tamura, Naoki
2005-01-01
Background Recently, wearable technology has been used in various health-related fields to develop advanced monitoring solutions. However, the monitoring function alone cannot meet all the requirements of customizing machine-based exercise on an individual basis by relying on biosignal-based controls. We propose a new wearable unit design equipped with measurement and control functions to support the customization process. Methods The wearable unit can measure the heart rate and electromyogram signals during exercise performance and output workload control commands to the exercise machines. The workload is continuously tracked with exercise programs set according to personally customized workload patterns and estimation results from the measured biosignals by a fuzzy control method. Exercise programs are adapted by relying on a computer workstation, which communicates with the wearable unit via wireless connections. A prototype of the wearable unit was tested together with an Internet-based cycle ergometer system to demonstrate that it is possible to customize exercise on an individual basis. Results We tested the wearable unit in nine people to assess its suitability to control cycle ergometer exercise. The results confirmed that the unit could successfully control the ergometer workload and continuously support gradual changes in physical activities. Conclusion The design of wearable units equipped with measurement and control functions is an important step towards establishing a convenient and continuously supported wellness environment. PMID:15982425
Low loss pole configuration for multi-pole homopolar magnetic bearings
NASA Technical Reports Server (NTRS)
Blumenstock, Kenneth A. (Inventor); Hakun, Claef F. (Inventor)
2001-01-01
A new pole configuration for multi-pole homopolar bearings proposed in this invention reduces rotational losses caused by eddy-currents generated when non-uniform flux distributions exist along the rotor surfaces. The new homopolar magnetic bearing includes a stator with reduced pole-to-pole and exhibits a much more uniform rotor flux than with large pole-to-pole gaps. A pole feature called a pole-link is incorporated into the low-loss poles to provide a uniform pole-to-pole gap and a controlled path for pole-to-pole flux. In order to implement the low-loss pole configuration of magnetic bearings with small pole-to-pole gaps, a new stator configuration was developed to facilitate installation of coil windings. The stator was divided into sector shaped pieces, as many pieces as there are poles. Each sector-shaped pole-piece can be wound on a standard coil winding machine, and it is practical to wind precision layer wound coils. To achieve maximum actuation efficiency, it is desirable to use all the available space for the coil formed by the natural geometric configuration. Then, the coils can be wound in a tapered shape. After winding, the sectored-pole-pieces are installed into and fastened by bonding or other means, to a ring of material which encloses the sectored-pole-pieces, forming a complete stator.
Autumn at Titan's South Pole: The 220 cm-1 Cloud
NASA Astrophysics Data System (ADS)
Jennings, D. E.; Cottini, V.; Achterberg, R. K.; Anderson, C. M.; Flasar, F. M.; de Kok, R. J.; Teanby, N. A.; Coustenis, A.; Vinatier, S.
2015-10-01
Beginning in 2012 an atmospheric cloud known by its far-infrared emission has formed rapidly at Tit an's South Pole [1, 2]. The build-up of this condensate is a result of deepening temperatures and a gathering of gases as Winter approaches. Emission from the cloud in the south has been doubling each year since 2012, in contrast to the north where it has halved every 3.8 years since 2004. The morphology of the cloud in the south is quite different from that in the north. In the north, the cloud has extended over the whole polar region beyond 55 N, whereas in the south the cloud has been confined to within about 10 degrees of the pole. The cloud in the north has had the form of a uniform hood, whereas the southern cloud has been much more complex. A map from December 2014,recorded by the Composite Infrared Spectrometer (CIRS) on Cassini, showed the 220 cm-1 emission coming from a distinct ring with a maximum at about 80 S. In contrast, emissions from the gases HC3N, C4H2 and C6H6 peaked near the pole and had a ring at 70 S. The 220 cm-1 ring at 80 S coincided with the minimum in the gas emission pattern. The80 S condensate ring encompassed the vortex cloud seen by the Cassini Imaging Science Subsystem (ISS) and Visible and Infrared Mapping Spectrometer (VIMS)[3, 4]. Both the 220 cm-1 ring and the gas "bull's-eye" pattern were centered on a point that was shifted from the geographic South Pole by 4 degrees in the direction of the Sun. This corresponds to the overall tilt of Titan's atmosphere discovered from temperature maps early in the Cassini mission by Achterberg et al. [5]. The tilt may be reinforced by the presumably twice-yearly (north and south) spin-up of the atmosphere at the autumnal pole. The bull's-eye pattern of the gas emissions can be explained by the retrieved abundance distributions, which are maximum near the pole and decrease sharply toward lower latitudes, together with temperatures that are minimum at the pole and increase toward lower latitudes. The increasing temperatures overcome the decreasing gas abundances to produce emission in the narrow range around 70 S. This cannot, however, explain the maximum of emission at 80 S from the condensate ring. The coincidence at 80 S of the 220 cm-1 peak with the gas emission minimum may indicate where the condensation is taking place. The central, polar minimum in the cloud emission may be due to faster rain-out and smaller extinction cross-sections. Spectral maps from 2013-15 [6] show that the gas emission pattern has been evolving quickly, with noticeable changes from one flyby to the next (about one month). The bull's-eye structure appears to have been most prominent in early 2014 and by late 2014 the pattern was becoming more uniform. As Titan progresses through late southern Autumn we expect the morphology of the condensate cloud to take on a hood-like distribution similar to that in the north.
Burbank exercises on the CEVIS
2011-12-04
ISS030-E-007559 (4 Dec. 2011) --- NASA astronaut Dan Burbank, Expedition 30 commander, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2016-06-16
iss047e154247 (6/16/2016) --- View of Commander Tim Kopra exercising on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) in the U.S. Laboratory. Photo was taken during Expedition 47.
Grade influences blood lactate kinetics during cross-country skiing.
LaRoche, Dain P; Amann, Markus; Rundell, Kenneth W
2010-01-01
The purpose of this study was to examine the effects of level vs. graded skate skiing on capillary blood lactate (B(La)), heart rate (HR), oxygen consumption (V(O2)), and training intensity prescriptions. Eleven Nordic skiers completed 2 submaximal skate roller skiing treadmill protocols during which intensity was increased either by grade (G(inc)) or by speed (S(inc)). The protocols were compared for prethreshold BLa, HR, and V(O2) at lactate threshold (LT) and the HR/V(O2) relationship. Additionally, double-pole (primarily upper body) and skating (arms and legs combined) protocols were used to measure peak V(O2) and peak HR. Heart rate and V(O2) at LT were lower during G(inc) compared with S(inc) (154.9 +/- 6.8 b.min(-1) vs. 162.0 +/- 9.1 b.min(-1) and 46.3 +/- 2.8 ml.kg(-1).min(-1) vs. 49.1 +/- 1.6 ml.kg(-1).min(-1), respectively, both p < 0.01). Pre-threshold B(La) and the HR/V(O2) relationship were not different between the submaximal protocols. V(O2) and HRpeak were higher in skating compared with double poling (64.6 +/- 1.8 ml.kg(-1).min(-1) vs. 60.3 +/- 2.8 ml.kg(-1).min(-1), 192.6 +/- 5.8 b.min(-1) vs. 187.8 +/- 6.7 b.min(-1), respectively, both p < 0.01). Greater reliance on upper-body musculature during graded skiing and its associated lower aerobic capacity increases B(La) when compared with level skiing. The leftward shift in the B(La) vs. intensity curve during uphill skiing should be recognized to properly prescribe training intensity as well as interpret laboratory results.
Grangeon, Romain; Zupan, John R.; Anderson-Furgeson, James; Zambryski, Patricia C.
2015-01-01
Agrobacterium tumefaciens elongates by addition of peptidoglycan (PG) only at the pole created by cell division, the growth pole, whereas the opposite pole, the old pole, is inactive for PG synthesis. How Agrobacterium assigns and maintains pole asymmetry is not understood. Here, we investigated whether polar growth is correlated with novel pole-specific localization of proteins implicated in a variety of growth and cell division pathways. The cell cycle of A. tumefaciens was monitored by time-lapse and superresolution microscopy to image the localization of A. tumefaciens homologs of proteins involved in cell division, PG synthesis and pole identity. FtsZ and FtsA accumulate at the growth pole during elongation, and improved imaging reveals FtsZ disappears from the growth pole and accumulates at the midcell before FtsA. The L,D-transpeptidase Atu0845 was detected mainly at the growth pole. A. tumefaciens specific pole-organizing protein (Pop) PopZAt and polar organelle development (Pod) protein PodJAt exhibited dynamic yet distinct behavior. PopZAt was found exclusively at the growing pole and quickly switches to the new growth poles of both siblings immediately after septation. PodJAt is initially at the old pole but then also accumulates at the growth pole as the cell cycle progresses suggesting that PodJAt may mediate the transition of the growth pole to an old pole. Thus, PopZAt is a marker for growth pole identity, whereas PodJAt identifies the old pole. PMID:26324921
Rakhman, A.; Hafez, Mohamed A.; Nanda, Sirish K.; ...
2016-03-31
Here, a high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532 nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064 nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO 3 crystal. The maximum achieved green power at 5 W infrared pump power is 1.74 W with a total conversion efficiency of 34.8%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7 kW with a corresponding enhancementmore » of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0% precision in polarization measurements of an electron beam with energy and current of 1.0 GeV and 50 μA.« less
Feltz, Deborah L; Ploutz-Snyder, Lori; Winn, Brian; Kerr, Norbert L; Pivarnik, James M; Ede, Alison; Hill, Christopher; Samendinger, Stephen; Jeffery, William
2016-11-14
Astronauts may have difficulty adhering to exercise regimens at vigorous intensity levels during long space missions. Vigorous exercise is important for aerobic and musculoskeletal health during space missions and afterwards. A key impediment to maintaining vigorous exercise is motivation. Finding ways to motivate astronauts to exercise at levels necessary to mitigate reductions in musculoskeletal health and aerobic capacity have not been explored. The focus of Simulated Partners and Collaborative Exercise (SPACE) is to use recently documented motivation gains in task groups to heighten the exercise experience for participants, similar in age and fitness to astronauts, for vigorous exercise over a 6-month exercise regimen. A secondary focus is to determine the most effective features in simulated exercise partners for enhancing enjoyment, self-efficacy, and social connectedness. The aims of the project are to (1) Create software-generated (SG) exercise partners and interface software with a cycle ergometer; (2) Pilot test design features of SG partners within a video exercise game (exergame), and (3) Test whether exercising with an SG partner over 24-week time period, compared to exercising alone, leads to greater work effort, aerobic capacity, muscle strength, exercise adherence, and enhanced psychological parameters. This study was approved by the Institutional Review Board (IRB). Chronic exercisers, between the ages 30 and 62, were asked to exercise on a cycle ergometer 6 days per week for 24 weeks using a routine consisting of alternating between moderate-intensity continuous and high-intensity interval sessions. Participants were assigned to one of three conditions: no partner (control), always faster SG partner, or SG partner who was not always faster. Participants were told they could vary cycle ergometer output to increase or decrease intensity during the sessions. Mean change in cycle ergometer power (watts) from the initial continuous and 4 min. interval sessions was the primary dependent variable reflecting work effort. Measures of physiological, strength, and psychological parameters were also taken. This paper describes the rationale, development, and methods of the SPACE exergame. We believe this will be a viable intervention that can be disseminated for astronaut use and adapted for use by other populations.
Preliminary feasibility study of a new method of hypothermia in an experimental canine model
Sert, İbrahim Ünal; Akand, Murat; Kılıç, Özcan; Yavru, Nuri; Bulut, Ersan
2017-01-01
Objective To build up a new microcontroller thermoelectric system to achieve renal hypothermia. Material and methods Renal hypothermia system was tested under in vivo conditions in the kidneys of ten Mongrel dogs. Ambient temperature was evaluated using two different microcontrollers. In order to ensure hypothermia in the renal parenchyma, selection can be made among 4 modules and sensors which detect the temperature of the area. The temperature range of the system was adjusted between −50°C and +50°C. Results When single and double poles of the kidney were cooled, initial mean intraperitoneal temperature values were found 37.7°C for rectum and 36.5°C for renal cortex and medulla. After the temperature of the cooling module was set to 12°C, the module was placed on the poles of the kidney. After fifteen minutes, temperature was 15.4°C in the lower pole of the kidney, 28.1°C in the cortex of the other side and 29.2°C in the intramedullary region. The temperature was found to be 15°C in the vicinity and 26.1°C in the cortex across the module. After the system was stabilized, a very slight change was observed in the temperature. Conclusion Hypothermia system developed ensured desired cooling of the targeted part of the kidney; however, it did not cause a change in the temperature of other parts of the kidney or general body temperature. Thus, it was possible to create a long-term study area for renal parenchymal surgery. PMID:28861307
Preliminary feasibility study of a new method of hypothermia in an experimental canine model.
Sert, İbrahim Ünal; Akand, Murat; Kılıç, Özcan; Yavru, Nuri; Bulut, Ersan
2017-09-01
To build up a new microcontroller thermoelectric system to achieve renal hypothermia. Renal hypothermia system was tested under in vivo conditions in the kidneys of ten Mongrel dogs. Ambient temperature was evaluated using two different microcontrollers. In order to ensure hypothermia in the renal parenchyma, selection can be made among 4 modules and sensors which detect the temperature of the area. The temperature range of the system was adjusted between -50°C and +50°C. When single and double poles of the kidney were cooled, initial mean intraperitoneal temperature values were found 37.7°C for rectum and 36.5°C for renal cortex and medulla. After the temperature of the cooling module was set to 12°C, the module was placed on the poles of the kidney. After fifteen minutes, temperature was 15.4°C in the lower pole of the kidney, 28.1°C in the cortex of the other side and 29.2°C in the intramedullary region. The temperature was found to be 15°C in the vicinity and 26.1°C in the cortex across the module. After the system was stabilized, a very slight change was observed in the temperature. Hypothermia system developed ensured desired cooling of the targeted part of the kidney; however, it did not cause a change in the temperature of other parts of the kidney or general body temperature. Thus, it was possible to create a long-term study area for renal parenchymal surgery.
Mastracchio exercises on the CEVIS
2013-11-22
ISS038-E-007156 (22 Nov. 2013) --- NASA astronaut Rick Mastracchio, Expedition 38 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2012-02-05
ISS030-E-063871 (5 Feb. 2012) --- NASA astronaut Don Pettit, Expedition 30 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2013-07-06
ISS036-E-015570 (6 July 2013) --- European Space Agency astronaut Luca Parmitano, Expedition 36 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2017-04-30
iss051e029335 (April 30, 2017) --- European Space Agency astronaut Thomas Pesquet exercises on the Cycle Ergometer with Vibration Isolation and Stabilization System (CEVIS), the station’s exercise bike, inside the Destiny laboratory module.
2011-05-11
ISS027-E-030045 (11 May 2011) --- NASA astronaut Ron Garan, Expedition 27 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2014-06-02
ISS040-E-006699 (2 June 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
FE Williams exercising on the CEVIS
2012-07-21
ISS032-E-008595 (20 July 2012) --- NASA astronaut Sunita Williams, Expedition 32 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2014-06-02
ISS040-E-006700 (2 June 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2009-06-08
ISS020-E-007607 (8 June 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 20 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2013-10-03
ISS037-E-006471 (3 Oct. 2013) --- European Space Agency astronaut Luca Parmitano, Expedition 37 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2011-02-25
S133-E-006027 (25 Feb. 2011) --- Astronaut Michael Barratt, STS-133 mission specialist, works out on the bicycle ergometer on Discovery's middeck during flight day 2 activities. Photo credit: NASA or National Aeronautics and Space Administration
NASA Technical Reports Server (NTRS)
Berry, P.; Berry, I.; Arnaud, S.; Moseley, M.
1987-01-01
Nineteen volunteers in bed with head down tilt (-6 deg) for 1 month and doing or not exercise training while in bed (lido or ergometer) had their limb muscle studied by magnetic resonance spectroscopy. A protocol of repetitive exercise in the magnet was set and a wooden probe designed to support the limb and to allow exercise. Spectra were recorded continuously during the protocol. In each spectrum, inorganic phosphate, phosphocreatin, adenosin triphosphate, and pH were measured. All the subjects were studied before, after bedrest, and 6 weeks later. After 1 month, the lido group show no changes in the spectra of their leg muscles while the group doing no exercise or ergometer do. For the arms, a loss of muscle function is only seen in the group doing no exercise.
Mason, Barry; Lenton, John; Leicht, Christof; Goosey-Tolfrey, Victoria
2014-01-01
The purpose of the study was to determine which laboratory-based modality provides the most valid physiological and biomechanical representation of over-ground sports wheelchair propulsion. Fifteen able-bodied participants with previous experience of wheelchair propulsion performed a 3-minute exercise trial at three speeds (4, 6 and 8 km ∙ h(-1)) in three testing modalities over separate sessions: (i) over-ground propulsion on a wooden sprung surface; (ii) wheelchair ergometer propulsion; (iii) treadmill propulsion at four different gradients (0%, 0.7%, 1.0% and 1,3%). A 0.7% treadmill gradient was shown to best reflect the oxygen uptake (7.3 to 9.1% coefficient of variation (CV)) and heart rate responses (4.9 to 6.4% CV) of over-ground propulsion at 4 and 6 km ∙ h(-1). A 1.0% treadmill gradient provided a more valid representation of oxygen uptake during over-ground propulsion at 8 km ∙ h(-1) (8.6% CV). Physiological demand was significantly underestimated in the 0% gradient and overestimated in the 1.3% gradient and wheelchair ergometer trials compared to over-ground trials (P<0.05). No laboratory-based modality provided a valid representation of the forces applied during OG (≥ 18.4% CV). To conclude, a 0.7% treadmill gradient is recommended to replicate over-ground wheelchair propulsion at lower speeds (4 and 6 km ∙ h(-1)) whereas a 1.0% gradient may be more suitable at 8 km ∙ h(-1).
Formenti, Federico; Minetti, Alberto E; Borrani, Fabio
2015-01-01
Estimation of human oxygen uptake () during exercise is often used as an alternative when its direct measurement is not feasible. The American College of Sports Medicine (ACSM) suggests estimating human during exercise on a cycle ergometer through an equation that considers individual's body mass and external work rate, but not pedaling rate (PR). We hypothesized that including PR in the ACSM equation would improve its prediction accuracy. Ten healthy male participants’ (age 19–48 years) were recruited and their steady-state was recorded on a cycle ergometer for 16 combinations of external work rates (0, 50, 100, and 150 W) and PR (50, 70, 90, and 110 revolutions per minute). was calculated by means of a new equation, and by the ACSM equation for comparison. Kinematic data were collected by means of an infrared 3-D motion analysis system in order to explore the mechanical determinants of . Including PR in the ACSM equation improved the accuracy for prediction of sub-maximal during exercise (mean bias 1.9 vs. 3.3 mL O2 kg−1 min−1) but it did not affect the accuracy for prediction of maximal (P > 0.05). Confirming the validity of this new equation, the results were replicated for data reported in the literature in 51 participants. We conclude that PR is an important determinant of human during cycling exercise, and it should be considered when predicting oxygen consumption. PMID:26371230
Motl, Robert W; Fernhall, Bo
2012-03-01
To examine the accuracy of predicting peak oxygen consumption (VO(2peak)) primarily from peak work rate (WR(peak)) recorded during a maximal, incremental exercise test on a cycle ergometer among persons with relapsing-remitting multiple sclerosis (RRMS) who had minimal disability. Cross-sectional study. Clinical research laboratory. Women with RRMS (n=32) and sex-, age-, height-, and weight-matched healthy controls (n=16) completed an incremental exercise test on a cycle ergometer to volitional termination. Not applicable. Measured and predicted VO(2peak) and WR(peak). There were strong, statistically significant associations between measured and predicted VO(2peak) in the overall sample (R(2)=.89, standard error of the estimate=127.4 mL/min) and subsamples with (R(2)=.89, standard error of the estimate=131.3 mL/min) and without (R(2)=.85, standard error of the estimate=126.8 mL/min) multiple sclerosis (MS) based on the linear regression analyses. Based on the 95% confidence limits for worst-case errors, the equation predicted VO(2peak) within 10% of its true value in 95 of every 100 subjects with MS. Peak VO(2) can be accurately predicted in persons with RRMS who have minimal disability as it is in controls by using established equations and WR(peak) recorded from a maximal, incremental exercise test on a cycle ergometer. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Wang, Zun; Wang, Lei; Fan, Hongjuan; Jiang, Wenjun; Wang, Sheng; Gu, Zhaohua; Wang, Tong
2014-09-01
[Purpose] To evaluate the feasibility and efficacy of adapted low intensity ergometer aerobic training for early and severely impaired stroke survivors. [Subjects] The subjects were forty-eight early stroke survivors. [Methods] Eligible subjects were recruited and randomly assigned to an experimental group and a control group. Both groups participated in comprehensive rehabilitation training. Low intensity aerobic training was only performed by the experimental group. Outcome measures were the Fugl-Meyer motor score, Barthel index, exercise test time, peak heart rate, plasma glucose level and serum lipid profiles. [Results] Patients in the experimental group finished 88.6% of the total aerobic training sessions prescribed. In compliant participants (adherence≥80%), aerobic training significantly improved the Barthel index (from 40.1±21.1 to 79.2±14.2), Fugl-Meyer motor score (from 26.4±19.4 to 45.4±12.7), exercise test time (from 12.2±3.62 min to 13.9±3.6 min), 2-hour glucose level (from 9.22±1.16 mmol/L to 7.21±1.36 mmol/L) and homeostasis model of assessment for insulin resistence index (from 1.72±1.01 to 1.28±0.88). [Conclusion] Preliminary findings suggest that early and severely impaired stroke patients may benefit from low intensity ergometer aerobic training.
Electromyographic and neuromuscular fatigue thresholds as concepts of fatigue.
Mäestu, Jarek; Cicchella, Antonio; Purge, Priit; Ruosi, Sergio; Jürimäe, Jaak; Jürimäe, Toivo
2006-11-01
The aim of this study was to investigate the concepts of electromyographic (EMG) threshold (EMGT) by integrated EMG (iEMG) signals and neuromuscular fatigue threshold (NMFT) concepts in trained male athletes. Nine competitive national-level male rowers (21.8 +/- 4.4 years; 186.2 +/- 4.6 cm; 79.6 +/- 8.4 kg) took part in this investigation. Subjects were asked to participate in the graded exercise test to volitional exhaustion and 500-, 1,000-, and 2,000-m all-out rowing ergometer tests on a rowing ergometer. During all tests, oxygen consumption parameters, average power, and iEMG of the musculus vastus lateralis were recorded. The second ventilatory threshold (248.9 +/- 26.67 W) and EMGT (258.89 +/- 27.13 W) were not significantly different but were significantly lower than the NMFT (302.25 +/- 45.10 W). During 1,000- and 2,000-m all-out distances, VO(2) increased during the first minute and then leveled on a plateau with a slight decrease at the end of the exercise. Vastus lateralis activity showed a slight increase during all distances that was accompanied by a remarkable increase towards the end of the distance. All measured threshold values were significantly correlated (r > 0.70; p < 0.05) to the rowing ergometer performance characteristics. It was concluded that EMGT is closely related to the aerobic-anaerobic transition phase, because NMFT represents the local fatigue accumulation in the muscle. NMFT indicates the performance capacity of the muscles; therefore, it helps coaches to better predict top athletes' performance.
Method and apparatus for assembling a permanent magnet pole assembly
Carl, Jr., Ralph James; Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Dawson, Richard Nils [Voorheesville, NY; Qu, Ronghai [Clifton Park, NY; Avanesov, Mikhail Avramovich [Moscow, RU
2009-08-11
A pole assembly for a rotor, the pole assembly includes a permanent magnet pole including at least one permanent magnet block, a plurality of laminations including a pole cap mechanically coupled to the pole, and a plurality of laminations including a base plate mechanically coupled to the pole.
MacDowell, Alastair A; Celestre, Rich S; Howells, Malcolm; McKinney, Wayne; Krupnick, James; Cambie, Daniella; Domning, Edward E; Duarte, Robert M; Kelez, Nicholas; Plate, David W; Cork, Carl W; Earnest, Thomas N; Dickert, Jeffery; Meigs, George; Ralston, Corie; Holton, James M; Alber, Tom; Berger, James M; Agard, David A; Padmore, Howard A
2004-11-01
At the Advanced Light Source, three protein crystallography beamlines have been built that use as a source one of the three 6 T single-pole superconducting bending magnets (superbends) that were recently installed in the ring. The use of such single-pole superconducting bend magnets enables the development of a hard X-ray program on a relatively low-energy 1.9 GeV ring without taking up insertion-device straight sections. The source is of relatively low power but, owing to the small electron beam emittance, it has high brightness. X-ray optics are required to preserve the brightness and to match the illumination requirements for protein crystallography. This was achieved by means of a collimating premirror bent to a plane parabola, a double-crystal monochromator followed by a toroidal mirror that focuses in the horizontal direction with a 2:1 demagnification. This optical arrangement partially balances aberrations from the collimating and toroidal mirrors such that a tight focused spot size is achieved. The optical properties of the beamline are an excellent match to those required by the small protein crystals that are typically measured. The design and performance of these new beamlines are described.
Capalbo, Luisa; D'Avino, Pier Paolo; Archambault, Vincent; Glover, David M.
2011-01-01
The small GTPase Rab5 is a conserved regulator of membrane trafficking; it regulates the formation of early endosomes, their transport along microtubules, and the fusion to the target organelles. Although several members of the endocytic pathway were recently implicated in spindle organization, it is unclear whether Rab5 has any role during mitosis. Here, we describe that Rab5 is required for proper chromosome alignment during Drosophila mitoses. We also found that Rab5 associated in vivo with nuclear Lamin and mushroom body defect (Mud), the Drosophila counterpart of nuclear mitotic apparatus protein (NuMA). Consistent with this finding, Rab5 was required for the disassembly of the nuclear envelope at mitotic entry and the accumulation of Mud at the spindle poles. Furthermore, Mud depletion caused chromosome misalignment defects that resembled the defects of Rab5 RNAi cells, and double-knockdown experiments indicated that the two proteins function in a linear pathway. Our results indicate a role for Rab5 in mitosis and reinforce the emerging view of the contributions made by cell membrane dynamics to spindle function. PMID:21987826
All optical wavelength broadcast based on simultaneous Type I QPM broadband SFG and SHG in MgO:PPLN.
Gong, Mingjun; Chen, Yuping; Lu, Feng; Chen, Xianfeng
2010-08-15
We experimentally demonstrate wavelength broadcast based on simultaneous Type I quasi-phase-matched (QPM) broadband sum-frequency generation (SFG) and second-harmonic generation (SHG) in 5 mol.% MgO-doped periodically poled lithium niobate (MgO:PPLN). One signal has been synchronously converted into seven different wavelengths using two pumps at a 1.5 microm band via quadratic cascaded nonlinear wavelength conversion. By selecting different pump regions, i.e., selecting different cascaded chi((2)):chi((2)) interactions, the flexible wavelength conversions with shifting from one signal to single, double, and triple channels were also demonstrated.
Kuznetsov, Stephen B.
1987-01-01
A system for casting liquid metals is provided with an electromagnetic pump which includes a pair of primary blocks each having a polyphase winding and being positioned to form a gap through which a movable conductive heat sink passes. A solidifying liquid metal sheet is deposited on the heat sink and the heat sink and sheet are held in compression by forces produced as a result of current flow through the polyphase windings. Shaded-pole interaction between the primary windings, heat sink and solidifying strip produce transverse forces which act to center the strip on the heat sink.
Kuznetsov, S.B.
1987-01-13
A system for casting liquid metals is provided with an electromagnetic pump which includes a pair of primary blocks each having a polyphase winding and being positioned to form a gap through which a movable conductive heat sink passes. A solidifying liquid metal sheet is deposited on the heat sink and the heat sink and sheet are held in compression by forces produced as a result of current flow through the polyphase windings. Shaded-pole interaction between the primary windings, heat sink and solidifying strip produce transverse forces which act to center the strip on the heat sink. 5 figs.
NASA Astrophysics Data System (ADS)
Ko, Kwang-Hoon; Kim, Yonghee; Park, Hyunmin; Cha, Yong-Ho; Kim, Taek-Soo; Lee, Lim; Lim, Gwon; Han, Jaemin; Ko, Kwang-Hee; Jeong, Do-Young
2015-08-01
Continuous-wave single-frequency tunable 544- and 272-nm beams have been demonstrated by the second- and fourth-harmonic conversions of a 1088-nm fundamental beam from a diode-oscillator fiber-amplifier. The single-pass second-harmonic generation with a MgO-doped periodically poled stoichiometric LiTaO3 crystal and the external-cavity frequency-doubling technique with a bulk BBO crystal were employed to achieve an approximately 6-W 544-nm beam and a 1.5-W 272-nm beam, respectively. We characterized the second- and fourth-harmonic generations and discussed their applications to calcium spectroscopy.
A Josephson Junction based SPDT switch
NASA Astrophysics Data System (ADS)
Zhang, Helin; Earnest, Nathan; Lu, Yao; Ma, Ruichao; Chakram, Srivatsan; Schuster, David
RF microwave switches are useful tools in cryogenic experiments, allowing for multiple experiments to be connected to a single cryogenic measurement chain. However, these switches dissipate a substantial amount of heat, preventing fast switching. Josephson junction (JJ) are a promising avenue for realizing millikelvin microwave switching. We present a JJ based single-pole-double throw (SPDT) switch that has fast switching time, no heat dissipation, large on/off contrast, and works over a wide bandwidth. The switch can be used for real-time switching between experiments, routing single photons, or even generating entanglement. We will describe the design of the switch and present experimental characterization of its performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rakhman, A.; Hafez, Mohamed A.; Nanda, Sirish K.
Here, a high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532 nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064 nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO 3 crystal. The maximum achieved green power at 5 W infrared pump power is 1.74 W with a total conversion efficiency of 34.8%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7 kW with a corresponding enhancementmore » of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0% precision in polarization measurements of an electron beam with energy and current of 1.0 GeV and 50 μA.« less
Crewmember exercising on the mid deck ergometer.
NASA Technical Reports Server (NTRS)
1992-01-01
Mission Specialist Ellen Baker exercising on an excercise bike attached to the Isolated/Stabilized Exercise Platform (ISEP) on the shuttle middeck. The ISEP is intended to insulate sensitive micregravity experiments from vibration caused by crew excercise.
Expedition 32 FE Acaba exercises on the CEVIS
2012-07-21
ISS032-E-009028 (21 July 2012) --- NASA astronaut Joe Acaba, Expedition 32 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Burbank exercises on the CEVIS in the U.S. Laboratory
2011-12-09
ISS030-E-010646 (9 Dec. 2011) --- NASA astronaut Dan Burbank, Expedition 30 commander, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Burbank exercises on the CEVIS in the U.S. Laboratory
2011-12-09
ISS030-E-010644 (9 Dec. 2011) --- NASA astronaut Dan Burbank, Expedition 30 commander, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Tani Exercises on the CEVIS in the US Lab
2008-02-06
ISS016-E-027899 (6 Feb. 2008) --- Astronauts Daniel Tani, Expedition 16 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2009-06-22
ISS020-E-013983 (22 June 2009) --- European Space Agency astronaut Frank De Winne, Expedition 20 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Coleman exercises on the CEVIS in the U.S. Laboratory
2011-01-20
ISS026-E-018823 (20 Jan. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
2012-12-31
ISS034-E-010622 (31 Dec. 2012) --- Canadian Space Agency astronaut Chris Hadfield, Expedition 34 flight engineer, performs a periodic fitness evaluation on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
ISS Expedition 18 Fincke on Cycle Egrometer with Vibration Isolation System (CEVIS)
2008-10-29
ISS018-E-005710 (29 Oct. 2008) --- Astronaut Michael Fincke, Expedition 18 commander, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Burbank exercises on the CEVIS in the U.S. Lab
2012-01-02
ISS030-E-032829 (2 Jan. 2012) --- NASA astronaut Dan Burbank, Expedition 30 flight commander, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Coleman exercises on the CEVIS in the U.S. Laboratory
2011-01-20
ISS026-E-018816 (20 Jan. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Ford exercises on the CEVIS in the U.S. Laboratory
2013-03-04
ISS034-E-061648 (4 March 2013) --- Inside the U.S. lab Destiny on the Earth-orbiting International Space Station, Expedition 34 Commander Kevin Ford exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS).
Pettit exercises on the CEVIS in the U.S. Laboratory
2012-01-15
ISS030-E-032768 (15 Jan. 2012) --- NASA astronaut Don Pettit, Expedition 30 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Ivanishin exercises on the CEVIS in the U.S. Laboratory
2011-12-10
ISS030-E-012738 (10 Dec. 2011) --- Russian cosmonaut Anatoly Ivanishin, Expedition 30 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Coleman exercises on the CEVIS in the U.S. Laboratory
2011-01-20
ISS026-E-018821 (20 Jan. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
1972-05-01
This is a wide-angle view of the Orbital Workshop lower level experiment area. In center foreground is the ergometer bicycle. In center background is a litter chair for the Human Vestibular Function experiment (Skylab Experiment M131) and in right background is the Lower Body Negative Pressure System experiment (Skylab Experiment M092). The ergometer bicycle was used for metabolic activity experiments and exercise. The purpose of the Human Vestibular (irner ear) Function experiment was to examine the effect of weightlessness on man's sensitivity and susceptibility to motion rotation, and his perception of orientation. The Lower Body Negative Pressure experiment investigated the relationship between the zero gravity environment and cardiovascular deconditioning. A characteristic of cardiovascular deconditoning is the partial failure of the blood vessels resulting in the excessive pooling of the blood in the legs when a person assumes an erect posture in a gravity field. The Marshall Space Flight Center had the program management responsibility for the development of Skylab hardware and experiments.
1972-05-01
This photograph shows technicians performing a checkout of the Metabolic Analyzer (center background) and the Ergometer (foreground) in the Orbital Workshop (OWS). The shower compartment is at right. The Ergometer (Skylab Experiment M171) evaluated man's metabolic effectiveness and cost of work in space environment. Located in the experiment and work area of the OWS, the shower compartment was a cylindrical cloth enclosure that was folded flat when not in use. The bottom ring of the shower was fastened to the floor and contained foot restraints. The upper ring contained the shower head and hose. To use the shower, the astronaut filled a pressurized portable bottle with heated water and attached the bottle to the ceiling. A flexible hose cornected the water bottle to a handheld shower head. The astronaut pulled the cylindrical shower wall up into position and bathed, using liquid soap. Both soap and water were carefully rationed, having been premeasured for economical use.
East Meets West on "Double Star", a Joint Mission to Explore Earth's Magnetic Field
NASA Astrophysics Data System (ADS)
2001-07-01
ESA Director General Antonio Rodotà and Luan Enjie, Administrator of the CNSA, signed an official agreement that will enable European experiments to be flown on Chinese satellites for the first time. "This agreement marks a significant advance for international cooperation in the exploration and peaceful use of outer space," said Mr. Rodotà. "It is one of the most important landmarks in scientific collaboration since ESA and the People's Republic of China first agreed to exchange scientific information more than 20 years ago." "The Double Star programme will be just the first step in substantial cooperation between the Chinese National Space Administration and ESA" said Mr Luan Enjie. "The signing of today's agreement paves the way not only for reciprocal cooperation between scientists, but for the establishment of comprehensive cooperation between the two agencies". Double Star will follow in the footsteps of ESA's groundbreaking Cluster mission by studying the effects of the Sun on the Earth's environment. Conducting joint studies with Cluster and Double Star should increase the overall scientific return from both missions. A key aspect of ESA's participation in the Double Star project is the inclusion of 10 instruments that are identical to those currently flying on the four Cluster spacecraft. A further eight experiments will be provided by Chinese institutes. "We hope it will be possible to make coordinated measurements with both Cluster and Double Star." said Cluster Project Scientist Philippe Escoubet. "For example, we would hope to carry out a joint exploration of the magnetotail, a region where storms of high energy particles are generated. When these particles reach Earth, they can cause power cuts, damage satellites and disrupt communications." Six of the eleven Cluster principal investigators have agreed to provide flight spares or duplicates of the experiments that are currently revolutionising our understanding of near-Earth space. This reuse of Cluster instruments has a number of advantages for both European and Chinese scientists. "By flying experiments identical to those on Cluster, we can reduce costs and development time," explained Alberto Gianolio, ESA Project Manager for Double Star. "This will minimise risk and help us to ensure that we are able to meet the spacecraft development schedule." ESA has agreed to contribute 8 million euros to the Double Star programme. This funding will be used for refurbishment and pre-integration of the European instruments, acquisition of data for 4 hours per day and coordination of scientific operations. Notes for Editors: Double Star will be the first mission launched by China to explore the Earth's magnetosphere - the magnetic bubble that surrounds our planet. As its name suggests, Double Star will involve two satellites - each designed, developed, launched and operated by the CNSA - flying in complementary orbits around the Earth. This orbital configuration will enable scientists to obtain simultaneous data on the changing magnetic field and population of electrified particles in different regions of the magnetosphere. The duo is expected to be launched by Chinese Long March 2C rockets in December 2002 and March 2003. This schedule may enable them to operate alongside ESA's Cluster mission - a mini-flotilla of four identical spacecraft launched into elliptical orbits around the Earth last summer. The "equatorial" spacecraft (DSP-1) will be launched into an elliptical orbit of 550 x 60,000 km, inclined at 28.5 degrees to the equator. This will enable it to investigate the Earth's huge magnetic tail, the region where particles are accelerated towards the planet's magnetic poles by a process known as reconnection. The "polar" satellite (DSP-2) will concentrate on physical processes taking place over the magnetic poles and the development of aurorae. It will have a 350 x 25,000 km orbit taking it round the Earth once every 7.3 hours.
Complete supine percutaneous nephrolithotomy with GoPro®. Ten steps for success.
Vicentini, Fabio Carvalho; Dos Santos, Hugo Daniel Barone; Batagello, Carlos Alfredo; Amundson, Julia Rothe; Oliveira, Evaristo Peixoto; Marchini, Giovanni Scala; Srougi, Miguel; Nahas, Willian Carlos; Mazzucchi, Eduardo
2018-03-15
To show a video of a complete supine Percutaneous Nephrolithotomy (csPCNL) performed for the treatment of a staghorn calculus, from the surgeon's point of view. The procedure was recorded with a GoPro® camera, demonstrating the ten essential steps for a successful procedure. The patient was a 38 years-old woman with 2.4cm of left kidney lower pole stone burden who presented with 3 months of lumbar pain and recurrent urinary tract infections. She had a previous diagnosis of polycystic kidney disease and chronic renal failure stage 2. CT scan showed two 1.2cm stones in the lower pole (Guy's Stone Score 2). She had a previous ipsilateral double J insertion due to an obstructive pyelonephritis. The csPCNL was uneventful with a single access in the lower pole. The surgeon had a Full HD GoPro Hero 4 Session® camera mounted on his head, controlled by the surgical team with a remote control. All of the mains steps were recorded. Informed consent was obtained prior to the procedure. The surgical time was 90 minutes. Hemoglobin drop was 0.5g/dL. A post-operative CT scan was stone-free. The patient was discharged 36 hours after surgery. The camera worked properly and didn't cause pain or muscle discomfort to the surgeon. The quality of the recorded movie was excellent. GoPro® camera proved to be a very interesting tool to document surgeries without interfering with the procedure and with great educational potential. More studies should be conducted to evaluate the role of this equipment. Copyright® by the International Brazilian Journal of Urology.
Marcinik, E J; Hodgdon, J A; Englund, C E; O'Brien, J J
1987-01-01
Pre- and post-physiological data were collected on 57 Navy men (mean age = 19.5 years) who participated in either circuit weight training/continuous run (CWT/CR) (N = 31) or circuit weight training/interval run (CWT/IR) (N = 26) programs. Measured variables included 4 measures of upper torso dynamic strength (one repetition maximum [1 RM] for arm curl, bench press, shoulder press, and lat pull-down); two measures of lower torso dynamic strength (1 RM) for knee extension and leg press); one measure of power (number of revolutions completed on an arm ergometer (Monark) at maximum drag); three measures of muscular endurance (number of repetitions at 60% 1 RM for bench press and leg press and maximal number of bent-knee sit-ups in 120 s); one stamina measure (time to exhaustion on a cycle ergometer (Monark) maximal work capacity [MWC] test; and three simulated shipboard tasks: manikin shoulder drag, open/secure a water tight door and paint bucket carry. Composite shipboard performance derived from the summed time (s) required to complete the three tasks was also calculated. Results show performance on the manikin shoulder drag and majority of evaluative fitness measures was significantly (p less than 0.05) enhanced following both circuit weight training/run formats. Significantly (p less than 0.05) higher values for shoulder press (F = 7.2), arm ergometer (F = 5.3), and sit-ups (F = 6.8) and lower values for leg press muscular endurance (F = 5.1) were observed in CWT/IR when compared to CWT/CR.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Stamatakos, N. G.; McCarthy, D. D.
2016-12-01
A CONVENTIONAL MEAN POLE PATH The gradual drift of the pole associated with the rotational axis of the Earth in a terrestrial reference frame is characterized by the motion of a "mean pole." The IERS Conventions (2010) does not provide a formal definition of such a "mean pole." In its glossary it defines the terminology "mean pole" in the celestial frame by using the definition "the position on the celestial sphere towards which the Earth's axis points at a particular epoch, with the oscillations due to precession-nutation removed." The need for a terrestrial mean pole is mentioned in Section 7.1.4 of the IERS Conventions, which outlines the procedure to account for the variation in terrestrial site coordinates caused by the pole tide. It states, that an estimate of the wander of the mean pole to within about 10 milliarc-seconds is needed to ensure that the geopotential field is aligned to the long term mean pole. Historically the angular coordinates of this "mean pole" were calculated by averaging the observed angular coordinates of the rotational pole over six years, the beat period of the annual and approximately 14-month Chandler motions of the rotational pole. The IERS Conventions (2010) realization of the mean pole is composed of a cubic fit of the polar coordinates valid over 1976-2010 and a linear model for extrapolation after 2010.0. Further it notes that in the future, the IERS conventional mean pole will be revised as needed with sufficient advance notice. However, this document leaves open the formal definition of a conventional terrestrial mean pole, the spectral frequency content to be expected in such a definition and a procedure to be used to realize the coordinates of the path for users. Background is provided regarding past realizations of a "mean pole," and the requirements for a realization of a mean pole path are reviewed. Possible definitions and potential mathematical models to provide mean pole coordinates in the future are outlined. In addition, the authors hope that this poster will serve to open a discussion, which will identify geodesy disciplines that require a mean pole and what type of definition would be suitable to their needs.
Hussain, Faruqe; Clasen, Thomas; Akter, Shahinoor; Bawel, Victoria; Luby, Stephen P; Leontsini, Elli; Unicomb, Leanne; Barua, Milan Kanti; Thomas, Brittany; Winch, Peter J
2017-05-25
In rural Bangladesh, India and elsewhere, pour-flush pit latrines are the most common sanitation system. When a single pit latrine becomes full, users must empty it themselves and risk exposure to fresh feces, pay an emptying service to remove pit contents or build a new latrine. Double pit pour-flush latrines may serve as a long-term sanitation option including high water table areas because the pits do not need to be emptied immediately and the excreta decomposes into reusable soil. Double pit pour-flush latrines were implemented in rural Bangladesh for 'hardcore poor' households by a national NGO, BRAC. We conducted interviews, focus groups, and spot checks in two low-income, rural areas of Bangladesh to explore the advantages and limitations of using double pit latrines compared to single pit latrines. The rural households accepted the double pit pour-flush latrine model and considered it feasible to use and maintain. This latrine design increased accessibility of a sanitation facility for these low-income residents and provided privacy, convenience and comfort, compared to open defecation. Although a double pit latrine is more costly and requires more space than a single pit latrine the households perceived this sanitation system to save resources, because households did not need to hire service workers to empty pits or remove decomposed contents themselves. In addition, the excreta decomposition process produced a reusable soil product that some households used in homestead gardening. The durability of the latrine superstructures was a problem, as most of the bamboo-pole superstructure broke after 6-18 months of use. Double pit pour-flush latrines are a long-term improved sanitation option that offers users several important advantages over single pit pour-flush latrines like in rural Bangladesh which can also be used in areas with high water table. Further research can provide an understanding of the comparative health impacts and effectiveness of the model in preventing human excreta from entering the environment.
NASA Technical Reports Server (NTRS)
Goodrich, Winston D. (Inventor); Wesselski, Clarence J. (Inventor); Pelischek, Timothy E. (Inventor); Becker, Bruce H. (Inventor); Kahn, Jon B. (Inventor); Grimaldi, Margaret E. (Inventor); McManamen, John P. (Inventor); Castro, Edgar O. (Inventor)
1989-01-01
A Shuttle type of aircraft (10) with an escape hatch (12) has an arcuately shaped pole housing (16) attachable to an interior wall and ceiling with its open end adjacent to the escape hatch. The pole housing 16 contains a telescopically arranged and arcuately shaped primary pole member (22) and extension pole member (23) which are guided by roller assemblies (30,35). The extension pole member (23) is slidable and extendable relative to the primary pole member (22). For actuation, a spring actuated system includes a spring (52) in the pole housing. A locking member (90) engages both pole members (22,23) through notch portions (85,86) in the pole members. The locking member selectively releases the extension pole member (23) and the primary pole member (22). An internal one-way clutch or anti-return mechanism prevents retraction of the extension pole member from an extended position. Shock absorbers (54)(150,152) are for absoring the energy of the springs. A manual backup deployment system is provided which includes a canted ring (104) biased by a spring member (108). A lever member (100) with a slot and pin connection (102) permits the mechanical manipulation of the canted ring to move the primary pole member. The ring (104) also prevents retraction of the main pole. The crew escape mechanism includes a magazine (60) and a number of lanyards (62), each lanyard being mounted by a roller loop (68) over the primary pole member (22). The strap on the roller loop has stitching for controlled release, a protection sheath (74) to prevent tangling and a hook member (69) for attachment to a crew harness.
Reisman exercises on the CEVIS in the U.S. Laboratory during Expedition 17
2008-05-11
ISS017-E-006668 (11 May 2008) --- NASA astronaut Garrett Reisman, Expedition 17 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Swanson exercises on the CEVIS in the US Lab
2014-04-22
ISS039-E-014696 (22 April 2014) --- Expedition 39 Flight Engineer Steve Swanson of NASA, works out on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the U.S. lab Destiny of the International Space Station.
Antonelli and Phillips setup Cycle Ergometer on Middeck (MDDK)
2009-03-19
S119-E-006662 (19 March 2009) --- Astronauts Tony Antonelli (left), STS-119 pilot; and John Phillips, mission specialist, pose for a photo on the middeck of Space Shuttle Discovery while docked with the International Space Station.
Near-IR, blue, and UV generation by frequency conversion of a Tm:YAP laser
NASA Astrophysics Data System (ADS)
Cole, Brian; Goldberg, Lew; Chinn, Steve
2018-02-01
We describe generation of near-infrared (944nm, 970nm), blue (472nm, 485nm), and UV (236 nm) light by frequency up-conversion of 2 μm output of a compact and efficient passively Q-switched Tm:YAP laser. The Tm:YAP laser source was near diffraction limited with maximum Q-switched pulse peak power of 190 kW. For second harmonic generation (SHG) of NIR, both periodically poled lithium niobate (PPLN) and lithium tri-borate (LBO) were evaluated, with 58% conversion efficiency and 3.1 W of 970 nm power achieved with PPLN. The PPLN 970nm emission was frequency doubled in 20mm long type I LBO, generating 1.1 W at 485nm with a conversion efficiency of 34%. With LBO used for frequency doubling of 2.3 W of 1888 nm Tm:YAP output to 944nm, 860mW was generated, with 37% conversion efficiency. Using a second LBO crystal to generate the 4th harmonic, 545mW of 472nm power was generated, corresponding to 64% conversion efficiency. To generate the 8th harmonic of Tm:YAP laser emission, the 472nm output of the second LBO was frequency doubled in a 7mm long BBO crystal, generating 110 mW at 236nm, corresponding to 21% conversion efficiency.
NASA Astrophysics Data System (ADS)
Kaltenbach, André; Hofmann, Julian; Seidel, Dirk; Lauritsen, Kristian; Bugge, Frank; Fricke, Jörg; Paschke, Katrin; Erdmann, Rainer; Tränkle, Günther
2017-02-01
A miniaturized picosecond pulsed semiconductor laser source in the spectral range around 560nm is realized by integrating a frequency doubled distributed Bragg reflector ridge waveguide laser (DBR-RWL) into a micromodule. Such compact laser sources are suitable for mobile application, e.g. in microscopes. The picosecond optical pulses are generated by gain-switching which allows for arbitrary pulse repetition frequencies. For frequency conversion a periodically poled magnesium doped lithium niobate ridge waveguide crystal (PPLN) is used to provide high conversion efficiency with single-pass second harmonic generation (SHG). The coupling of the pulsed radiation into the PPLN crystal is realized by a GRIN-lens. Such types of lenses collect the divergent laser radiation and focus it into the crystal waveguide providing high coupling efficiency at a minimum of space compared to the usage of fast axis collimator(FAC)/slow axis collimator (SAC) lens combinations. The frequency doubled output pulses show a pulse width of about 60 ps FWHM and a spectral width around 0.06nm FWHM at a central wavelength of 557nm at 15Å. The pulse peak power could be determined to be more than 300mW at a repetition frequency of 40 MHz.
Code of Federal Regulations, 2014 CFR
2014-10-01
... default rate of return; (xi) The average amount of usable space per pole for those poles used for pole... unusable space per pole for those poles used for pole attachments (a 24 foot presumption may be used in...) The number of ducts in the conduit subject to the complaint; (vi) The number of inner-ducts in the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... default rate of return; (xi) The average amount of usable space per pole for those poles used for pole... unusable space per pole for those poles used for pole attachments (a 24 foot presumption may be used in...) The number of ducts in the conduit subject to the complaint; (vi) The number of inner-ducts in the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... default rate of return; (xi) The average amount of usable space per pole for those poles used for pole... unusable space per pole for those poles used for pole attachments (a 24 foot presumption may be used in...) The number of ducts in the conduit subject to the complaint; (vi) The number of inner-ducts in the...
Validation of the Pulmonary Function System for Use on the International Space Station
NASA Technical Reports Server (NTRS)
McCleary, Frank A.; Moore, Alan D., Jr.; Hagan, R. Donald
2007-01-01
Aerobic deconditioning occurs during long duration space flight despite the use of exercise countermeasures (Convertino, 1996). As a part of International Space Station (ISS) medical operations, periodic tests designed to estimate aerobic capacity are performed to track changes in aerobic fitness and to determine the effectiveness of exercise countermeasures. These tests are performed prior to, during, and after missions of greater than 30 days in duration. Crewmembers selected for missions aboard the ISS perform a graded exercise test on a cycle ergometer approximately 270 days prior to their scheduled launch date in order to measure peak oxygen consumption (VO2PK) and peak heart rate (HRpk). Approximately 30 to 45 days prior to launch, crewmembers perform a submaximal cycle ergometer test at work rates set to elicit 25, 50 and 75% of their pre-flight VO2PK. This test, known as the Periodic Fitness Evaluation (PFE), serves as a baseline measure to which subsequent in-and post-flight exercise tests are compared. While onboard the ISS, crewmembers are normally scheduled to perform the PFE beginning with flight day (FD) 14 and every 30 days thereafter. The PFE is also conducted 5 and 30 days following flight. Using PFE data, aerobic fitness is estimated by quantifying the VO2 vs. HR relationship using linear regression and calculating the VO2 that would occur at the crewmember s previously measured HRpk. Currently, for data collected during flight, this technique assumes that the pre- vs. in-flight oxygen consumption per given cycle workload is similar. However, the validity of this assumption is based upon a sparse amount of data collected during the Skylab era (Michel, et al. 1977). The method of using heart rate and cycle ergometer work rates has been used to estimate aerobic fitness in normal gravity (Astrand and Ryhming, 1954; Lee, 1993). Due to spaceflight induced physiological alterations, such as shifts in extracellular fluid (e.g. plasma) volume, this method may not be valid during space flight. In addition, the ergometer onboard ISS is vibration-isolated and moves with the astronaut s application of force into the pedals. The effect of this movement on the VO2 of cycle exercise on ISS has not been quantified.
Analog Exercise Hardware to Implement a High Intensity Exercise Program During Bed Rest
NASA Technical Reports Server (NTRS)
Loerch, Linda; Newby, Nate; Ploutz-Snyder, Lori
2012-01-01
Background: In order to evaluate novel countermeasure protocols in a space flight analog prior to validation on the International Space Station (ISS), NASA's Human Research Program (HRP) is sponsoring a multi-investigator bedrest campaign that utilizes a combination of commercial and custom-made exercise training hardware to conduct daily resistive and aerobic exercise protocols. This paper will describe these pieces of hardware and how they are used to support current bedrest studies at NASA's Flight Analog Research Unit in Galveston, TX. Discussion: To implement candidate exercise countermeasure studies during extended bed rest studies the following analog hardware are being utilized: Stand alone Zero-Gravity Locomotion Simulator (sZLS) -- a custom built device by NASA, the sZLS allows bedrest subjects to remain supine as they run on a vertically-oriented treadmill (0-15 miles/hour). The treadmill includes a pneumatic subject loading device to provide variable body loading (0-100%) and a harness to keep the subject in contact with the motorized treadmill to provide a ground reaction force at their feet that is quantified by a Kistler Force Plate. Supine Cycle Ergometer -- a commercially available supine cycle ergometer (Lode, Groningen, Netherlands) is used for all cycle ergometer sessions. The ergometer has adjustable shoulder supports and handgrips to help stabilize the subject during exercise. Horizontal Squat Device (HSD) -- a custom built device by Quantum Fitness Corp (Stafford, TX), the HSD allows for squat exercises to be performed while lying in a supine position. The HSD can provide 0 to 600 pounds of force in selectable 5 lb increments, and allows hip translation in both the vertical and horizontal planes. Prone Leg Curl -- a commercially available prone leg curl machine (Cybex International Inc., Medway, MA) is used to complete leg curl exercises. Horizontal Leg Press -- a commercially available horizontal leg press (Quantum Fitness Corporation) is used for leg press and heel raise exercises. Minor modifications were made to the device including adding 200 lbs to the weight stack, raising the frame by 12 inches, making the footplate adjustable, and providing removable handles. Conclusion: A combination of novel and commercial exercise hardware are used to mimic the exercise hardware capabilities aboard the ISS, allowing scientific investigation of new countermeasure protocols in a space flight analog prior to flight validation
Zhang, Rubin; Zhan, Likui; Sun, Shaoming; Peng, Wei; Sun, Yining
2017-09-01
The maximum oxygen uptake (V̇O 2 max), determined from graded maximal or submaximal exercise tests, is used to classify the cardiorespiratory fitness level of individuals. The purpose of this study was to examine the validity and reliability of the YMCA submaximal exercise test protocol performed on a newly-designed rectilinear stepping ergometer (RSE) that used up and down reciprocating vertical motion in place of conventional circular motion and giving precise measurement of workload, to determine V̇O 2 max in young healthy male adults. Thirty-two young healthy male adults (32 males; age range: 20-35 years; height: 1.75 ± 0.05 m; weight: 67.5 ± 8.6 kg) firstly participated in a maximal-effort graded exercise test using a cycle ergometer (CE) to directly obtain measured V̇O 2 max. Subjects then completed the progressive multistage test on the RSE beginning at 50W and including additional stages of 70, 90, 110, 130, and 150W, and the RSE YMCA submaximal test consisting of a workload increase every 3 minutes until the termination criterion was reached. A metabolic equation was derived from the RSE multistage exercise test to predict oxygen consumption (V̇O 2 ) from power output (W) during the submaximal exercise test (V̇O 2 (mL·min -1 )=12.4 ×W(watts)+3.5 mL·kg -1 ·min -1 ×M+160mL·min -1 , R 2 = 0.91, standard error of the estimate (SEE) = 134.8mL·min -1 ). A high correlation was observed between the RSE YMCA estimated V̇O 2 max and the CE measured V̇O 2 max (r=0.87). The mean difference between estimated and measured V̇O 2 max was 2.5 mL·kg -1 ·min -1 , with an SEE of 3.55 mL·kg -1 ·min -1 . The data suggest that the RSE YMCA submaximal exercise test is valid for predicting V̇O 2 max in young healthy male adults. The findings show that the rectilinear stepping exercise is an effective submaximal exercise for predicting V̇O 2 max. The newly-designed RSE may be potentially further developed as an alternative ergometer for assessing cardiorespiratory fitness and the promotion of personalized health interventions for health care professionals.
Meeus, Mira; Hermans, Linda; Ickmans, Kelly; Struyf, Filip; Van Cauwenbergh, Deborah; Bronckaerts, Laura; De Clerck, Luc S; Moorken, Greta; Hans, Guy; Grosemans, Sofie; Nijs, Jo
2015-02-01
Temporal summation (TS) of pain, conditioned pain modulation (CPM), and exercise-induced analgesia (EIA) are often investigated in chronic pain populations as an indicator for enhanced pain facilitation and impaired endogenous pain inhibition, respectively, but interactions are not yet clear both in healthy controls and in chronic pain patients. Therefore, the present double-blind randomized placebo-controlled study evaluates pains cores, TS, and CPM in response to exercise in healthy controls, patients with chronic fatigue syndrome and comorbid fibromyalgia (CFS/FM), and patients with rheumatoid arthritis (RA), both under placebo and paracetamol condition. Fifty-three female volunteers - of which 19 patients with CFS/FM, 16 patients with RA, and 18 healthy controls - underwent a submaximal exercise test on a bicycle ergometer on 2 different occasions (paracetamol vs. placebo), with an interval of 7 days. Before and after exercise, participants rated pain intensity during TS and CPM. Patients with rheumatoid arthritis showed decreased TS after exercise, both after paracetamol and placebo (P < 0.05). In patients with CFS/FM, results were less univocal. A nonsignificant decrease in TS was only observed after taking paracetamol. CPM responses to exercise are inconclusive, but seem to worsen after exercise. No adverse effects were seen. This study evaluates pain scores, TS, and CPM in response to submaximal exercise in 2 different chronic pain populations and healthy controls. In patients with RA, exercise had positive effects on TS, suggesting normal EIA. In patients with CFS/FM, these positive effects were only observed after paracetamol and results were inconsistent. © 2014 World Institute of Pain.
Abel, T; Knechtle, B; Perret, C; Eser, P; von Arx, P; Knecht, H
2005-06-01
The intake of arginine aspartate has been shown to increase anabolic hormones like human growth hormone (hGH) and glucagon. The aim of our study was to investigate whether daily intake of two different dosages of arginine asparate during four weeks affects selected parameters of overtraining syndrome like performance, metabolic and endocrine parameters. Thirty male endurance-trained athletes were included in a randomized, double-blind, placebo-controlled study and divided into three groups. During four weeks, they ingested either arginine aspartate with a high concentration (H) of 5.7 g arginine and 8.7 g aspartate, with a low concentration (L) of 2.8 g arginine and 2.2 g aspartate or placebo (P).VO(2)peak and time to exhaustion were determined on a cycling ergometer in an incremental exercise test before and after supplementation. Before and after each incremental exercise test, concentrations of hGH, glucagon, testosterone, cortisol, ferritine, lactate, and urea were measured. Compared to placebo, no significant differences on endurance performance (VO(2)peak, time to exhaustion), endocrine (concentration of hGH, glucagon, cortisol, and testosterone) and metabolic parameters (concentration of lactate, ferritine, and urea) were found after chronic arginine aspartate supplementation. The chronic intake of arginine asparate during four weeks by male endurance athletes showed independent of dosage no influence on performance, selected metabolic or endocrine parameters. Consequently, there seems to be no apparent reason why the supplementation of arginine aspartate should be an effective ergogenic aid. The practice of using arginine aspartate as potential ergogenics should be critically reevaluated. Further investigations with higher dosage and extended supplementation periods should be performed.
Mittal, Shivam Om; Machado, Duarte; Richardson, Diana; Dubey, Divyanshu; Jabbari, Bahman
2017-09-01
In essential tremor and Parkinson disease (PD) tremor, administration of onabotulinumtoxinA via a fixed injection approach improves the tremor, but many patients (30%-70%) develop moderate to severe hand weakness, limiting the use of onabotulinumtoxinA in clinical practice. To evaluate the safety and efficacy of incobotulinumtoxinA (IncoA) injection for the treatment of tremor in PD. In this double-blind, placebo-controlled, crossover trial, 30 patients each received 7 to 12 (mean, 9) IncoA injections into hand and forearm muscles using a customized approach. The study was performed from June 1, 2012, through June 30, 2015, and participants were followed for 24 weeks. Treatment efficacy was evaluated by the tremor subsets of the Unified Parkinson's Disease Rating Scale and the Patient Global Impression of Change 4 and 8 weeks after each of the 2 sets of treatments. Hand strength was assessed using an ergometer. There was a statistically significant improvement in clinical rating scores of rest tremor and tremor severity 4 and 8 weeks after the IncoA injection and of action/postural tremor at 8 weeks. There was a significant improvement in patient perception of improvement at 4 and 8 weeks in the IncoA group. There was no statistically significant difference in grip strength at 4 weeks between the 2 groups. Injection of IncoA via a customized approach improved PD tremor on a clinical scale and patient perception, with a low occurrence of significant hand weakness. clinicaltrials.gov Identifier: NCT02419313. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Billy Bohannan; Hermann Habermann; Joan E. Lengel
1974-01-01
Round wood pole use has changed without accompanying advancement in engineering design data. Previous pole design was based on the assumption that maximum stress occurred at the groundline but, with the larger poles that are now being used, maximum stress may occur along the pole length. For accurate engineering analysis the shape or taper of a pole must be known. Both...
Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.
1984-04-24
An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.
Thorn, C.E.; Chasman, C.; Baltz, A.J.
1981-11-19
An improved magnet more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.
CENTROSOMES AND MICROTUBULES DURING MEIOSIS IN THE MUSHROOM BOLETUS RUBINELLUS
McLaughlin, David J.
1971-01-01
The double centrosome in the basidium of Boletus rubinellus has been observed in three planes with the electron microscope at interphase preceding nuclear fusion, at prophase I, and at interphase I. It is composed of two components connected by a band-shaped middle part. At anaphase I a single, enlarged centrosome is found at the spindle pole, which is attached to the cell membrane. Microtubules mainly oriented parallel to the longitudinal axis of the basidium are present at prefusion, prophase I and interphase I. Cytoplasmic microtubules are absent when the spindle is present. The relationship of the centrosome in B. rubinellus to that in other organisms and the role of the cytoplasmic microtubules are discussed. PMID:4329156
Self Assembly and Pyroelectric Poling for Organics
2015-07-06
ozone or nitrogen oxides) and energetic species from corona discharge . These problems can strongly inhibit the efficient poling and large-scale...poling techniques. Although contact and corona poling protocols are quite well established for decades, there do exist some challenging problems. In...contact poling, severe charge injection from metal electrodes often results in large current that causes dielectric breakdown of films. Corona poling
Bellone, Stefania; Eliana, Bignotti; Lonardi, Silvia; Ferrari, Francesca; Centritto, Floriana; Masserdotti, Alice; Pettinella, Francesca; Black, Jonathan; Menderes, Gulden; Altwerger, Gary; Hui, Pei; Lopez, Salvatore; de Haydu, Christopher; Bonazzoli, Elena; Predolini, Federica; Zammataro, Luca; Cocco, Emiliano; Ferrari, Federico; Ravaggi, Antonella; Romani, Chiara; Facchettie, Fabio; Sartori, Enrico; Odicino, Franco E.; Silasi, Dan-Arin; Litkouhi, Babak; Ratner, Elena; Azodi, Masoud; Schwartz, Peter E.; Santin, Alessandro D.
2016-01-01
Objective Up to 12 % of all endometrial-carcinomas (EC) harbor DNA-polymerase-ε-(POLE) mutations. It is currently unknown whether the favorable prognosis of POLE-mutated EC is derived from their low metastatic capability, extraordinary number of somatic mutations thus imparting immunogenicity, or a high sensitivity to chemotherapy. Methods Polymerase-chain-reaction-amplification and Sanger-sequencing were used to test for POLE exonuclease-domain-mutations (exons 9–14) 131 EC. Infiltration of CD4+ and CD8+ T-lymphocytes (TIL) and PD-1-expression in POLE-mutated vs POLE wild-type EC was studied by immunohistochemistry (IHC) and the correlations between survival and molecular features were investigated. Finally, primary POLE-mutated and POLE-wild-type EC cell lines were established and compared in-vitro for their sensitivity to chemotherapy. Results Eleven POLE-mutated EC (8.5%) were identified. POLE-mutated tumors were associated with improved progression-free-survival (P<0.05) and displayed increased numbers of CD4+ (44.5 vs 21.8; P = .001) and CD8+ (32.8 vs 13.5; P < .001) TILs when compared to wild-type POLE EC. PD-1 receptor was overexpressed in TILs from POLE-mutated vs wild-type-tumors (81% vs 28%; P < .001). Primary POLE tumor cell lines were significantly more resistant to platinum-chemotherapy in-vitro when compared to POLE-wild-type tumors (P < 0.004). Conclusions POLE ultra-mutated EC are heavily infiltrated with CD4+/CD8+ TIL, overexpress PD-1 immune-check-point (i.e., features consistent with chronic antigen-exposure), and have a better prognosis when compared to other molecular subtypes of EC patients. POLE-mutated tumor-cell lines are resistant to platinum-chemotherapy in-vitro suggesting that the better prognosis of POLE-patients is not secondary to a higher sensitivity to chemotherapy but likely linked to enhanced immunogenicity. PMID:27894751
Han Roliadi; Chung Y. Hse; Elvin T. Choong; Todd F. Shupe
2000-01-01
Decay resistance of out-of-service poles was investigated to evaluate their effectiveness against biodegradation for possible recycling of these poles for composite products. Decay resistance was related to creosote content and creosote distribution in poles with service durations of 5 and 25 years and also freshly treated poles. Weathering of the poles had caused...
Single phase two pole/six pole motor
Kirschbaum, Herbert S.
1984-01-01
A single phase alternating current two pole/six pole motor is provided with a main stator winding having six coils disposed unequally around the periphery of the machine. These coils are divided into two groups. When these groups are connected such that their magnetomotive forces are additive, two pole motor operation results. When the polarity of one of the groups is then reversed, six pole motor operation results. An auxiliary stator winding which is similar to the main stator winding is displaced from the main stator winding by 90 electrical degrees on a two pole basis.
Pole pulling apparatus and method
McIntire, Gary L.
1989-01-01
An apparatus for removal of embedded utility-type poles which removes the poles quickly and efficiently from their embedded position without damage to the pole or surrounding structures. The apparatus includes at least 2 piston/cylinder members equally spaced about the pole, and a head member affixed to the top of each piston. Elongation of the piston induces rotation of the head into the pole to increase the gripping action and reduce slippage. Repeated actuation and retraction of the piston and head member will "jack" the pole from its embedded position.
Mou, Weimin; Nankoo, Jean-François; Zhou, Ruojing; Spetch, Marcia L
2014-03-01
Five experiments investigated how human adults use landmark arrays in the immediate environment to reorient relative to the local environment and relative to remote cities. Participants learned targets' directions with the presence of a proximal 4 poles forming a rectangular shape and an array of more distal poles forming a rectangular shape. Then participants were disoriented and pointed to targets with the presence of the proximal poles or the distal poles. Participants' orientation was estimated by the mean of their pointing error across targets. The targets could be 7 objects in the immediate local environment in which the poles were located or 7 cities around Edmonton (Alberta, Canada) where the experiments occurred. The directions of the 7 cities could be learned from reading a map first and then from pointing to the cities when the poles were presented. The directions of the 7 cities could also be learned from viewing labels of cities moving back and forth in the specific direction in the immediate local environment in which the poles were located. The shape of the array of the distal poles varied in salience by changing the number of poles on each edge of the rectangle (2 vs. 34). The results showed that participants regained their orientation relative to local objects using the distal poles with 2 poles on each edge; participants could not reorient relative to cities using the distal pole array with 2 poles on each edge but could reorient relative to cities using the distal pole array with 34 poles on each edge. These results indicate that use of cues in reorientation depends not only on the cue salience but also on which environment people need to reorient to.
Hsu, John S.
2010-05-18
A method and apparatus in which a stator (11) and a rotor (12) define a primary air gap (20) for receiving AC flux and at least one source (23, 40), and preferably two sources (23, 24, 40) of DC excitation are positioned for inducing DC flux at opposite ends of the rotor (12). Portions of PM material (17, 17a) are provided as boundaries separating PM rotor pole portions from each other and from reluctance poles. The PM poles (18) and the reluctance poles (19) can be formed with poles of one polarity having enlarged flux paths in relation to flux paths for pole portions of an opposite polarity, the enlarged flux paths communicating with a core of the rotor (12) so as to increase reluctance torque produced by the electric machine. Reluctance torque is increased by providing asymmetrical pole faces. The DC excitation can also use asymmetric poles and asymmetric excitation sources. Several embodiments are disclosed with additional variations.
NASA Astrophysics Data System (ADS)
Aggarwal, Priyanka; Sharma, Shivalika; Singh, Sunny; Kaur, Harsimran; Hazra, Ram Kuntal
2017-04-01
Inclusion of coulomb interaction emerges with the complexity of either convergence of integrals or separation of variables of Schrödinger equations. For an N-electron system, interaction terms grow by N(N-1)/2 factors. Therefore, 2-e system stands as fundamental basic unit for generalized N-e systems. For the first time, we have evaluated e-e correlations in very simple and absolutely terminating finite summed hypergeometric series for 2-D double carrier parabolic quantum dot in both zero and arbitrary non-zero magnetic field (symmetric gauge) and have appraised these integrals in variational methods. The competitive role among confinement strength, magnetic field, mass of the carrier and dielectric constant of the medium on energy level diagram, level-spacing statistics, heat capacities (Cv at 1 K) and magnetization (T ∼ (0-1)K) is studied on systems spanning over wide range of materials (GaAs,Ge,CdS,SiO2 and He, etc). We have also constructed an exact theory for generalized correlated N-e 2-D quantum dots via multi-pole expansion but for the sake of compactness of the article we refrain from data.
Mycobacteria Modify Their Cell Size Control under Sub-Optimal Carbon Sources
Priestman, Miles; Thomas, Philipp; Robertson, Brian D.; Shahrezaei, Vahid
2017-01-01
The decision to divide is the most important one that any cell must make. Recent single cell studies suggest that most bacteria follow an “adder” model of cell size control, incorporating a fixed amount of cell wall material before dividing. Mycobacteria, including the causative agent of tuberculosis Mycobacterium tuberculosis, are known to divide asymmetrically resulting in heterogeneity in growth rate, doubling time, and other growth characteristics in daughter cells. The interplay between asymmetric cell division and adder size control has not been extensively investigated. Moreover, the impact of changes in the environment on growth rate and cell size control have not been addressed for mycobacteria. Here, we utilize time-lapse microscopy coupled with microfluidics to track live Mycobacterium smegmatis cells as they grow and divide over multiple generations, under a variety of growth conditions. We demonstrate that, under optimal conditions, M. smegmatis cells robustly follow the adder principle, with constant added length per generation independent of birth size, growth rate, and inherited pole age. However, the nature of the carbon source induces deviations from the adder model in a manner that is dependent on pole age. Understanding how mycobacteria maintain cell size homoeostasis may provide crucial targets for the development of drugs for the treatment of tuberculosis, which remains a leading cause of global mortality. PMID:28748182
En Face Optical Coherence Tomography for Visualization of the Choroid.
Savastano, Maria Cristina; Rispoli, Marco; Savastano, Alfonso; Lumbroso, Bruno
2015-05-01
To assess posterior pole choroid patterns in healthy eyes using en face optical coherence tomography (OCT). This observational study included 154 healthy eyes of 77 patients who underwent en face OCT. The mean age of the patients was 31.2 years (standard deviation: 13 years); 40 patients were women, and 37 patients were men. En face imaging of the choroidal vasculature was assessed using an OCT Optovue RTVue (Optovue, Fremont, CA). To generate an appropriate choroid image, the best detectable vessels in Haller's layer below the retinal pigment epithelium surface parallel plane were selected. Images of diverse choroidal vessel patterns at the posterior pole were observed and recorded with en face OCT. Five different patterns of Haller's layer with different occurrences were assessed. Pattern 1 (temporal herringbone) represented 49.2%, pattern 2 (branched from below) and pattern 3 (laterally diagonal) represented 14.2%, pattern 4 (doubled arcuate) was observed in 11.9%, and pattern 5 (reticular feature) was observed in 10.5% of the reference plane. In vivo assessment of human choroid microvasculature in healthy eyes using en face OCT demonstrated five different patterns. The choroid vasculature pattern may play a role in the origin and development of neuroretinal pathologies, with potential importance in chorioretinal diseases and circulatory abnormalities. Copyright 2015, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Tsiapas, Elias
2016-04-01
When the Earth was formed, it was in a state of burning heat. As time went by, temperature on the planet's surface was falling due to radiation and heat transfer, and various components (crusts) began taking solid form at the Earth's poles. The formation of crusts took place at the Earth's poles, because the stirring of burning and fluid masses on the surface of the Earth was significantly slighter there than it was on the equator. Due to centrifugal force and Coriolis Effect, these solid masses headed towards the equator; those originating from the North Pole followed a south-western course, while those originating from the South Pole followed a north-western course and there they rotated from west to east at a lower speed than the underlying burning and liquid earth, because of their lower initial linear velocity, their solid state and inertia. Because inertia is proportional to mass, the initially larger solid body swept all new solid ones, incorporating them to its western side. The density of the new solid masses was higher, because the components on the surface would freeze and solidify first, before the underlying thicker components. As a result, the western side of the initial islet of solid rocks submerged, while the east side elevated. . As a result of the above, this initial islet began to spin in reverse, and after taking on the shape of a sphere, it formed the "heart" of the Moon. The Moon-sphere, rolling on the equator, would sink the solid rocks that continued to descend from the Earth's poles. The sinking rocks partially melted because of higher temperatures in the greater depths that the Moon descended to, while part of the rocks' mass bonded with the Moon and also served as a heat-insulating material, preventing the descended side of the sphere from melting. Combined with the Earth's liquid mass that covered its emerging eastern surface, new sphere-shaped shells were created, with increased density and very powerful structural cohesion. During the above mentioned process, the thick clouds surrounding Earth-Moon were causing heavy storms and on the outer surface of the rolling Moon, wherever small cavities - or pockets - existed, these would fill up with water. Then, due to the Moon's changing tilt, these pockets were sealed by sediments and as a result, small water tanks are scattered on the successive layers of the Moon, from its centre to its surface. . As this sphere (the Moon) continued to grow, the Earth-Moon system was displaying a double-planet image. The Moon's reverse rolling velocity increased according to the increase of its mass and volume. As the temperature on the surface of the Earth continued to fall, a larger number of bigger sized solid masses were descending from the poles towards the equator, and the Moon could no longer aggregate them. The gathering and interference of solid rocks of great mass acted as the catapult on which the Moon bounced off the Earth and was put into orbit around it.
NASA Astrophysics Data System (ADS)
Tsiapas, Elias; Soumelidou, Despina; Tsiapas, Christos
2017-04-01
When the Earth was formed, it was in a state of burning heat. As time went by, temperature on the planet's surface was falling due to radiation and heat transfer, and various components (crusts) began taking solid form at the Earth's poles. The formation of crusts took place at the Earth's poles, because the stirring of burning and fluid masses on the surface of the Earth was significantly slighter there than it was on the equator. Due to centrifugal force and Coriolis Effect, these solid masses headed towards the equator; those originating from the North Pole followed a south-western course, while those originating from the South Pole followed a north-western course and there they rotated from west to east at a lower speed than the underlying burning and liquid earth, because of their lower initial linear velocity, their solid state and inertia. Because inertia is proportional to mass, the initially larger solid body swept all new solid ones, incorporating them to its western side. The density of the new solid masses was higher, because the components on the surface would freeze and solidify first, before the underlying thicker components. As a result, the western side of the initial islet of solid rocks submerged, while the east side elevated. . As a result of the above, this initial islet began to spin in reverse, and after taking on the shape of a sphere, it formed the "heart" of the Moon. The Moon-sphere, rolling on the equator, would sink the solid rocks that continued to descend from the Earth's poles. The sinking rocks partially melted because of higher temperatures in the greater depths that the Moon descended to, while part of the rocks' mass bonded with the Moon and also served as a heat-insulating material, preventing the descended side of the sphere from melting. Combined with the Earth's liquid mass that covered its emerging eastern surface, new sphere-shaped shells were created, with increased density and very powerful structural cohesion. During the above mentioned process, the thick clouds surrounding Earth-Moon were causing heavy storms and on the outer surface of the rolling Moon, wherever small cavities - or pockets - existed, these would fill up with water. Then, due to the Moon's changing tilt, these pockets were sealed by sediments and as a result, small water tanks are scattered on the successive layers of the Moon, from its centre to its surface. . As this sphere (the Moon) continued to grow, the Earth-Moon system was displaying a double-planet image. The Moon's reverse rolling velocity increased according to the increase of its mass and volume. As the temperature on the surface of the Earth continued to fall, a larger number of bigger sized solid masses were descending from the poles towards the equator, and the Moon could no longer aggregate them. The gathering and interference of solid rocks of great mass acted as the catapult on which the Moon bounced off the Earth and was put into orbit around it.
NASA Astrophysics Data System (ADS)
Tsiapas, Elias
2015-04-01
When the Earth was formed, it was in a state of burning heat. As time went by, temperature on the planet's surface was falling due to radiation and heat transfer, and various components (crusts) began taking solid form at the Earth's poles. The formation of crusts took place at the Earth's poles, because the stirring of burning and fluid masses on the surface of the Earth was significantly slighter there than it was on the equator. Due to centrifugal force and Coriolis Effect, these solid masses headed towards the equator; those originating from the North Pole followed a south-western course, while those originating from the South Pole followed a north-western course and there they rotated from west to east at a lower speed than the underlying burning and liquid earth, because of their lower initial linear velocity, their solid state and inertia. Because inertia is proportional to mass, the initially larger solid body swept all new solid ones, incorporating them to its western side. The density of the new solid masses was higher, because the components on the surface would freeze and solidify first, before the underlying thicker components. As a result, the western side of the initial islet of solid rocks submerged, while the east side elevated. . As a result of the above, this initial islet began to spin in reverse, and after taking on the shape of a sphere, it formed the "heart" of the Moon. The Moon-sphere, rolling on the equator, would sink the solid rocks that continued to descend from the Earth's poles. The sinking rocks partially melted because of higher temperatures in the greater depths that the Moon descended to, while part of the rocks' mass bonded with the Moon and also served as a heat-insulating material, preventing the descended side of the sphere from melting. Combined with the Earth's liquid mass that covered its emerging eastern surface, new sphere-shaped shells were created, with increased density and very powerful structural cohesion. During the above mentioned process, the thick clouds surrounding Earth-Moon were causing heavy storms and on the outer surface of the rolling Moon, wherever small cavities - or pockets - existed, these would fill up with water. Then, due to the Moon's changing tilt, these pockets were sealed by sediments and as a result, small water tanks are scattered on the successive layers of the Moon, from its centre to its surface. . As this sphere (the Moon) continued to grow, the Earth-Moon system was displaying a double-planet image. The Moon's reverse rolling velocity increased according to the increase of its mass and volume. As the temperature on the surface of the Earth continued to fall, a larger number of bigger sized solid masses were descending from the poles towards the equator, and the Moon could no longer aggregate them. The gathering and interference of solid rocks of great mass acted as the catapult on which the Moon bounced off the Earth and was put into orbit around it.
NASA Astrophysics Data System (ADS)
Tsiapas, Elias
2014-05-01
When the Earth was formed, it was in a state of burning heat. As time went by, temperature on the planet's surface was falling due to radiation and heat transfer, and various components (crusts) began taking solid form at the Earth's poles. The formation of crusts took place at the Earth's poles, because the stirring of burning and fluid masses on the surface of the Earth was significantly slighter there than it was on the equator. Due to centrifugal force and Coriolis Effect, these solid masses headed towards the equator; those originating from the North Pole followed a south-western course, while those originating from the South Pole followed a north-western course and there they rotated from west to east at a lower speed than the underlying burning and liquid earth, because of their lower initial linear velocity, their solid state and inertia. Because inertia is proportional to mass, the initially larger solid body swept all new solid ones, incorporating them to its western side. The density of the new solid masses was higher, because the components on the surface would freeze and solidify first, before the underlying thicker components. As a result, the western side of the initial islet of solid rocks submerged, while the east side elevated. . As a result of the above, this initial islet began to spin in reverse, and after taking on the shape of a sphere, it formed the "heart" of the Moon. The Moon-sphere, rolling on the equator, would sink the solid rocks that continued to descend from the Earth's poles. The sinking rocks partially melted because of higher temperatures in the greater depths that the Moon descended to, while part of the rocks' mass bonded with the Moon and also served as a heat-insulating material, preventing the descended side of the sphere from melting. Combined with the Earth's liquid mass that covered its emerging eastern surface, new sphere-shaped shells were created, with increased density and very powerful structural cohesion. During the above mentioned process, the thick clouds surrounding Earth-Moon were causing heavy storms and on the outer surface of the rolling Moon, wherever small cavities - or pockets - existed, these would fill up with water. Then, due to the Moon's changing tilt, these pockets were sealed by sediments and as a result, small water tanks are scattered on the successive layers of the Moon, from its centre to its surface. . As this sphere (the Moon) continued to grow, the Earth-Moon system was displaying a double-planet image. The Moon's reverse rolling velocity increased according to the increase of its mass and volume. As the temperature on the surface of the Earth continued to fall, a larger number of bigger sized solid masses were descending from the poles towards the equator, and the Moon could no longer aggregate them. The gathering and interference of solid rocks of great mass acted as the catapult on which the Moon bounced off the Earth and was put into orbit around it..
Human and Mechanical Factors in Ergometry.
ERIC Educational Resources Information Center
Ellis, M. J.; Hubbard, R. P.
Analysis of the human and mechanical factors inherent in ergometry suggest many strategies for the improvement of experiments related to exertion. The resistive principles of gravitation, friction, elasticity, viscosity, magnetism, and inertia used in ergometers impose different restraints on experiments. The suitability of different resistive…
McArthur exercises on the CEVIS on Expedition 12
2006-01-03
ISS012-E-14206 (3 Jan. 2006) --- Astronaut William S. (Bill) McArthur Jr., Expedition 13 commander and NASA space station science officer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Kononenko exercises on the CEVIS in the U.S. Laboratory during Expedition 17
2008-05-11
ISS017-E-006662 (11 May 2008) --- Russian Federal Space Agency cosmonaut Oleg Kononenko, Expedition 17 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
1968-02-22
During a visit to the Marshall Space Flight Center (MSFC), the Congressional House Committee on Science and Astronautics toured the S-IVB workshop. Pictured here are MSFC’s Dr. Wernher von Braun (standing) and Congressman Miller, Democratic representative of California (sitting on the ergometer bicycle) inside the workshop.
NASA Technical Reports Server (NTRS)
Proctor, B. W.; Reysa, R. P.; Russell, D. J.
1975-01-01
Housekeeping, off-duty, and medical data concerning the appliances considered for the space station are presented. Appliance functions analyzed include: cleanup, collection, processing and storage of refuse; crew entertainment and physical exercise, and the autoclaves and ergometers.
Single phase two pole/six pole motor
Kirschbaum, H.S.
1984-09-25
A single phase alternating current two pole/six pole motor is provided with a main stator winding having six coils disposed unequally around the periphery of the machine. These coils are divided into two groups. When these groups are connected such that their magnetomotive forces are additive, two pole motor operation results. When the polarity of one of the groups is then reversed, six pole motor operation results. An auxiliary stator winding which is similar to the main stator winding is displaced from the main stator winding by 90 electrical degrees on a two pole basis. 12 figs.
Detection and Classification of Pole-Like Objects from Mobile Mapping Data
NASA Astrophysics Data System (ADS)
Fukano, K.; Masuda, H.
2015-08-01
Laser scanners on a vehicle-based mobile mapping system can capture 3D point-clouds of roads and roadside objects. Since roadside objects have to be maintained periodically, their 3D models are useful for planning maintenance tasks. In our previous work, we proposed a method for detecting cylindrical poles and planar plates in a point-cloud. However, it is often required to further classify pole-like objects into utility poles, streetlights, traffic signals and signs, which are managed by different organizations. In addition, our previous method may fail to extract low pole-like objects, which are often observed in urban residential areas. In this paper, we propose new methods for extracting and classifying pole-like objects. In our method, we robustly extract a wide variety of poles by converting point-clouds into wireframe models and calculating cross-sections between wireframe models and horizontal cutting planes. For classifying pole-like objects, we subdivide a pole-like object into five subsets by extracting poles and planes, and calculate feature values of each subset. Then we apply a supervised machine learning method using feature variables of subsets. In our experiments, our method could achieve excellent results for detection and classification of pole-like objects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anthony, R.W.; Bodig, J.; Phillips, G.E.
This report describes the development of a nondestructive evaluation (NDE) methodology for assessing the bending strength of new wood utility poles. Fundamental concepts of stress wave propagation are presented. The development of a longitudinal stress wave methodology for predicting pole strength and the results of destructive tests on full-size poles are described. Mathematical correlations between stress wave parameters, geometric characteristics, and individual pole bending strengths form the basis of strength prediction models for western redcedar, Douglas-fir and southern pine poles. Models were developed for NDE in the whitewood stage and after preservative treatment of poles. For each species the twomore » most commonly used preservative types were evaluated. Excellent correlations were obtained for western redcedar and Douglas-fir poles, but high moisture content in the southern pine poles resulted in lower prediction accuracies for this species. Verification of the developed mathematical models demonstrates that improvement in classifying poles into the ANSI 05.1 tip-load capacities is technically feasible. The development and field trial of the prototype equipment for strength grading of new poles is also described. Research results can be used to benefit utilities by enabling the supply of strength graded poles with a higher accuracy than previously possible.« less
Formation of a Bright Polar Hood over the Summer North Pole of Saturn in 2016
NASA Astrophysics Data System (ADS)
Sayanagi, Kunio M.; Blalock, John J.; Ingersoll, Andrew P.; Dyudina, Ulyana A.; Ewald, Shawn P.
2016-10-01
We report that a bright polar hood has formed over the north pole of Saturn, seen first in images captured by the Cassini ISS camera in 2016. When the north pole was observed during the previous period of Cassini spacecraft's high-inclination orbits in 2012-2013, the concentration of light-scattering aerosols within 2-degree latitude of the north pole appeared to be less than that of the surrounding region, and appeared as a dark hole in all ISS filters, in particular in the shorter wavelength filters BL1 (460 nm), and VIO (420 nm). The north pole's appearance in 2012 was in contrast to that of the south pole in 2007, when the south pole had a bright polar hood in those short wavelengths; the south pole appeared dark in all other ISS filters in 2007. The difference between the south pole in 2007 and the north pole in 2012 was interpreted to be seasonal; in 2007, Saturn was approaching the equinox of 2009 and the south pole had been continuously illuminated since the previous equinox in 1995. In 2012, the north pole had been illuminated for only ~3 years after the long winter polar night. The bright hood over the summer south pole in 2007 was hypothesized to consist of aerosols produced by ultraviolet photodissociation of hydrocarbon molecules. Fletcher et al (2015) predicted that a similar bright hood should form over the north pole as Saturn approaches the 2017 solstice. In 2016, the Cassini spacecraft raised its orbital inclination again in preparation for its Grande Finale phase of the mission, from where it has a good view of the north pole. New images captured in 2016 show that the north pole has developed a bright polar hood. We present new images of the north polar region captured in 2016 that show the north pole, and other seasonally evolving high-latitude features including the northern hexagon. Our research has been supported by the Cassini Project, NASA grants OPR NNX11AM45G, CDAPS NNX15AD33G PATM NNX14AK07G, and NSF grant AAG 1212216.
Casiraghi, Francesca; Lertwattanarak, Raweewan; Luzi, Livio; Chavez, Alberto O; Davalli, Alberto M; Naegelin, Terry; Comuzzie, Anthony G; Frost, Patricia; Musi, Nicolas; Folli, Franco
2013-01-01
The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with "gold standard", IC, in humans.
Somatotype variables related to strength and power output in male basketball players.
Buśko, Krzysztof; Pastuszak, Anna; Lipińska, Monika; Lipińska, Marta; Gryko, Karol
2017-01-01
The purpose of this study was to investigate the relationship between somatotype, muscular strength, power output measured in maximal cycle ergometer exercise bouts, and maximal power output and height of rise of the body mass centre (jump height) measured in akimbo counter movement jump (ACMJ), counter movement jump (CMJ) and spike jump (SPJ), in male basketball players. Thirteen male basketball players (second division, age 19.4 ± 0.8 years, body height 192.9 ± 5.6 cm, body mass 88.8 ± 8.6 kg, training experience 9.3 ± 0.8 years) participated in the study. Somatotype was determined using the Heath-Carter method. Maximal joint torques were measured under static conditions. Power output was measured in 2 maximal cycle ergometer exercise bouts, 10 seconds each, with increasing external loads equal to 7.5 and 10.0% of the body weight (BW). All jump trials (ACMJ, CMJ and SPJ) were performed on a force plate. The mean somatotype of basketball players amounted to: 2.8-4.2-3.2. The sum of the joint torques for left and right lower extremities (0.613), trunk (0.631) and all six measured muscle groups (0.647) were significantly correlated (p < 0.05) with the mesomorphic component. Endomorphic, mesomorphic and ectomorphic components were correlated insignificantly with values of maximal power and height of jump during ACMJ, CMJ and SPJ trials. The power output measured in maximal cycle ergometer exercise bouts with increasing external loads was significantly correlated (p < 0.05) with mesomorphy and ectomorphy. It can be assumed that basketball players' anthropometric characteristics can influence their level of performance but it is not a decisive factor.
Formenti, Federico; Minetti, Alberto E; Borrani, Fabio
2015-09-01
Estimation of human oxygen uptake (V˙o2) during exercise is often used as an alternative when its direct measurement is not feasible. The American College of Sports Medicine (ACSM) suggests estimating human V˙o2 during exercise on a cycle ergometer through an equation that considers individual's body mass and external work rate, but not pedaling rate (PR). We hypothesized that including PR in the ACSM equation would improve its V˙o2 prediction accuracy. Ten healthy male participants' (age 19-48 years) were recruited and their steady-state V˙o2 was recorded on a cycle ergometer for 16 combinations of external work rates (0, 50, 100, and 150 W) and PR (50, 70, 90, and 110 revolutions per minute). V˙o2 was calculated by means of a new equation, and by the ACSM equation for comparison. Kinematic data were collected by means of an infrared 3-D motion analysis system in order to explore the mechanical determinants of V˙o2. Including PR in the ACSM equation improved the accuracy for prediction of sub-maximal V˙o2 during exercise (mean bias 1.9 vs. 3.3 mL O2 kg(-1) min(-1)) but it did not affect the accuracy for prediction of maximal V˙o2 (P > 0.05). Confirming the validity of this new equation, the results were replicated for data reported in the literature in 51 participants. We conclude that PR is an important determinant of human V˙o2 during cycling exercise, and it should be considered when predicting oxygen consumption. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Hibi, N; Fujinaga, H; Ishii, K
1996-01-01
Work and power outputs during short-term, maximal exertion on a friction loaded cycle ergometer are usually calculated from the friction force applied to the flywheel. The inertia of the flywheel is sometimes taken into consideration, but the effects of internal resistances and other factors have been ignored. The purpose of this study was to estimate their effects by comparing work or power output determined from the force exerted on the pedals (pedalling force) with work or power output determined from the friction force and the moment of inertia of the rotational parts. A group of 22 male college students accelerated a cycle ergometer as rapidly as possible for 3 s. The total work output determined from the pedalling force (TWp) was significantly greater than that calculated from the friction force and the moment of inertia (TWf). Power output determined from the pedalling force during each pedal stroke (SPp) was also significantly greater than that calculated from the friction force and the moment of inertia. Percentage difference (% diff), defined by % diff = ¿(TWp - TWf)/TWf¿ x 100, ranged from 16.8% to 49.3% with a mean value of 30.8 (SD 9.1)%. It was observed that % diff values were higher in subjects with greater TWp or greater maximal SPp. These results would indicate that internal resistances and other factors, such as the deformation of the chain and the vibrations of the entire system, may have significant effects on the measurements of work and power outputs. The effects appear to depend on the magnitudes of pedalling force and pedal velocity.
Effect of water-based recovery on blood lactate removal after high-intensity exercise.
Lucertini, Francesco; Gervasi, Marco; D'Amen, Giancarlo; Sisti, Davide; Rocchi, Marco Bruno Luigi; Stocchi, Vilberto; Benelli, Piero
2017-01-01
This study assessed the effectiveness of water immersion to the shoulders in enhancing blood lactate removal during active and passive recovery after short-duration high-intensity exercise. Seventeen cyclists underwent active water- and land-based recoveries and passive water and land-based recoveries. The recovery conditions lasted 31 minutes each and started after the identification of each cyclist's blood lactate accumulation peak, induced by a 30-second all-out sprint on a cycle ergometer. Active recoveries were performed on a cycle ergometer at 70% of the oxygen consumption corresponding to the lactate threshold (the control for the intensity was oxygen consumption), while passive recoveries were performed with subjects at rest and seated on the cycle ergometer. Blood lactate concentration was measured 8 times during each recovery condition and lactate clearance was modeled over a negative exponential function using non-linear regression. Actual active recovery intensity was compared to the target intensity (one sample t-test) and passive recovery intensities were compared between environments (paired sample t-tests). Non-linear regression parameters (coefficients of the exponential decay of lactate; predicted resting lactates; predicted delta decreases in lactate) were compared between environments (linear mixed model analyses for repeated measures) separately for the active and passive recovery modes. Active recovery intensities did not differ significantly from the target oxygen consumption, whereas passive recovery resulted in a slightly lower oxygen consumption when performed while immersed in water rather than on land. The exponential decay of blood lactate was not significantly different in water- or land-based recoveries in either active or passive recovery conditions. In conclusion, water immersion at 29°C would not appear to be an effective practice for improving post-exercise lactate removal in either the active or passive recovery modes.
Gross efficiency and energy expenditure in kayak ergometer exercise.
Gomes, B B; Mourão, L; Massart, A; Figueiredo, P; Vilas-Boas, J P; Santos, A M C; Fernandes, R J
2012-08-01
We purposed to study energy expenditure, power output and gross efficiency during kayak ergometer exercise in 12 elite sprint kayakers. 6 males (age 24.2±4.8 years, height 180.4±4.8 cm, body mass 79.7±8.5 kg) and 6 females (age 24.3±4.5 years, height 164.5±3.9 cm, body mass 65.4±3.5 kg), performed an incremental intermittent protocol on kayak ergometer with VO2 and blood lactate concentration assessment, a non-linear increase between power output and energy expenditure being observed. Paddling power output, energy expenditure and gross efficiency corresponding to VO2max averaged 199.92±50.41 W, 75.27±6.30 ml.kg - 1.min - 1, and 10.10±1.08%. Male kayakers presented higher VO2max, power output and gross efficiency at the VO2max, and lower heart rate and maximal lactate concentration than females, but no differences were found between genders regarding energy expenditure at VO2max. Aerobic and anaerobic components of energy expenditure evidenced a significant contribution of anaerobic energy sources in sprint kayak performance. Results also suggested the dependence of the gross efficiency on the changes in the amount of the aerobic and anaerobic contributions, at heavy and severe intensities. The inter-individual variance of the relationship between energy expenditure and the corresponding paddling power output revealed a relevant tracking for females (FDγ=0.73±0.06), conversely to the male group (FDγ=0.27±0.08), supporting that some male kayakers are more skilled in some paddling intensities than others. © Georg Thieme Verlag KG Stuttgart · New York.
Ravier, G; Grappe, F; Rouillon, J D
2004-12-01
The aim of this study was to analyze the links between tests performances (vertical jump and force-velocity sprint on cycle ergometer) and 2 different karate level groups in order to propose a test battery adjusted to karate. Twenty-two karate competitors (10 national junior team (IJ) and 12 national competition level (NL)) performed 4 maximal squat jumps (SJ), 4 maximal counter movement jumps (CMJ) on an ergojump and 3 8-s sprints on a friction braked cycle ergometer (friction loads of 0.5, 0.7, 0.9 N x kg(-1)). The maximal theoretical force (F(0)) and velocity (V(0)), the maximal power output (P(max)) and the optimal pedalling velocity (V(opt)) were derived from both the force -- velocity and the power -- velocity relationships plotted from all the 3 friction loads data. V(0), F(0), V(opt), P(max) and the best SJ and CMJ, were compared between IJ and NL groups. The IJ group was characterised by significantly higher values of V(0) (+13%) and SJ (+14.3%) compared to NL group, whereas no significant difference was observed between groups for F(0). Thus, karate performance would depend on maximal velocity and explosive strength. In addition, V(opt) was significantly higher in IJ group compared to NL group (135.4 rpm vs 119.2 rpm, p<0.001). Although based upon indirect evidence, these results accounted for mechanical functional capabilities of experts which could be particularly valuable when monitoring training of karate competitor. A force-velocity and a vertical jump tests may be applied in the functional assessment of karate competitor.
Schaun, Gustavo Z; Del Vecchio, Fabrício B
2018-01-01
Schaun, GZ and Del Vecchio, FB. High-intensity interval exercises' acute impact on heart rate variability: comparison between whole-body and cycle ergometer protocols. J Strength Cond Res 32(1): 223-229, 2018-Study aimed to compare the effects of 2 high-intensity interval training (HIIT) protocols on heart rate variability. Twelve young adult males (23.3 ± 3.9 years, 177.8 ± 7.4 cm, 76.9 ± 12.9 kg) volunteered to participate. In a randomized cross-over design, subjects performed 2 HIIT protocols, 1 on a cycle ergometer (Tabata protocol [TBT]; eight 20-second bouts at 170% Pmax interspersed by 10-second rest) and another with whole-body calisthenic exercises (McRae protocol; eight 20-second all-out intervals interspersed by 10-second rest). Heart rate variability outcomes in the time, frequency, and nonlinear domains were assessed on 3 moments: (a) presession; (b) immediately postsession; and (c) 24 hours postsession. Results revealed that RRmean, Ln rMSSD, Ln high frequency (HF), and Ln low frequency (LF) were significantly reduced immediately postsession (p ≤ 0.001) and returned to baseline 24 h after both protocols. In addition, LF/HF ratio was reduced 24 h postsession (p ≤ 0.01) and SD2 was significantly lower immediately postsession only in TBT. Our main finding was that responses from heart rate autonomic control were similar in both protocols, despite different modes of exercise performed. Specifically, exercises resulted in a high parasympathetic inhibition immediately after session with subsequent recovery within 1 day. These results suggest that subjects were already recovered the day after and can help coaches to better program training sessions with such protocols.
Höchsmann, Christoph; Rossmeissl, Anja; Baumann, Sandra; Infanger, Denis; Schmidt-Trucksäss, Arno
2018-03-15
To examine cardiorespiratory exertion during mini trampoline exercises of different intensities in both endurance-trained athletes and overweight-obese adults. Physically healthy participants (Group A: normal-weight, endurance-trained athletes; Group B: inactive, overweight-obese adults) participated in two measurement appointments and three training sessions in between appointments, in which participants familiarized themselves with the use of the mini trampoline and the execution of the exercises. The primary outcome was the ⩒O 2peak for each of the six mini trampoline exercises relative to the ⩒O 2peak as established during an all-out exercise test on a bike ergometer during the first measurement appointment. Secondary outcomes were average ⩒O 2 as well as maximum and average heart rate. The six mini trampoline exercises generated ⩒O 2peak values between 42% and 81% in the endurance-trained athletes and between 58% and 87% in the overweight-obese participants, both in relation to the bike ergometer ⩒O 2peak . Average ⩒O 2 values ranged from 35% to 69% (endurance-trained athletes) and from 48% to 71% (overweight-obese participants), depending on exercise. Average heart rate likewise lay in a range that can be categorized as moderate-to-vigorous aerobic exercise for both groups. A moderate-to-strong correlation (0.658 to 0.875, depending on exercise) between bike ergometer ⩒O 2peak and mini trampoline ⩒O 2peak was found for all six exercises. Mini trampoline exercise has the potential to produce training intensities that concur with established exercise guidelines. The exercise intensity is self-adjusting and allows for an effective and safe workout for different users with a wide range of fitness levels.
Davy, John L
2012-08-01
The author has published equations for predicting the air borne sound transmission of double leaf cavity walls due to the structure borne sound transmission across the air cavity via (possibly resilient) line connections, but has never published the full derivation of these equations. The author also derived equations for the case when the connections are rigid point connections but has never used them or published them or their derivations. This paper will present the full derivation of the author's theory of the air borne sound transmission of double leaf cavity walls due to the structure borne sound transmission across the air cavity via point or line connections which are modeled as four pole networks. The theoretical results will be compared with experimental results on wooden stud cavity walls from the National Research Council of Canada because the screw spacing is given for these results. This enables connections via studs and screws to be modeled as point connections and avoids the need to make any assumptions about the compliance of the equivalent point or line connections.
Solar-Powered Cooler and Heater for an Automobile Interior
NASA Technical Reports Server (NTRS)
Howard, Richard T.
2006-01-01
The apparatus would include a solar photovoltaic panel mounted on the roof and a panellike assembly mounted in a window opening. The window-mounted assembly would include a stack of thermoelectric devices sandwiched between two heat sinks. A fan would circulate interior air over one heat sink. Another fan would circulate exterior air over the other heat sink. The fans and the thermoelectric devices would be powered by the solar photovoltaic panel. By means of a double-pole, double-throw switch, the panel voltage fed to the thermoelectric stack would be set to the desired polarity: For cooling operation, the chosen polarity would be one in which the thermoelectric devices transport heat from the inside heat sink to the outside one; for heating operation, the opposite polarity would be chosen. Because thermoelectric devices are more efficient in heating than in cooling, this apparatus would be more effective as a heater than as a cooler. However, if the apparatus were to include means to circulate air between the outside and the inside without opening the windows, then its effectiveness as a cooler in a hot, sunny location would be increased.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muljadi, Eduard; Hasan, Iftekhar; Husain, Tausif
In this paper, a nonlinear analytical model based on the Magnetic Equivalent Circuit (MEC) method is developed for a double-sided E-Core Transverse Flux Machine (TFM). The proposed TFM has a cylindrical rotor, sandwiched between E-core stators on both sides. Ferrite magnets are used in the rotor with flux concentrating design to attain high airgap flux density, better magnet utilization, and higher torque density. The MEC model was developed using a series-parallel combination of flux tubes to estimate the reluctance network for different parts of the machine including air gaps, permanent magnets, and the stator and rotor ferromagnetic materials, in amore » two-dimensional (2-D) frame. An iterative Gauss-Siedel method is integrated with the MEC model to capture the effects of magnetic saturation. A single phase, 1 kW, 400 rpm E-Core TFM is analytically modeled and its results for flux linkage, no-load EMF, and generated torque, are verified with Finite Element Analysis (FEA). The analytical model significantly reduces the computation time while estimating results with less than 10 percent error.« less
Geraghty, Robert; Burr, Jacob; Simmonds, Nick; Somani, Bhaskar K.
2015-01-01
Introduction: Shock wave lithotripsy (SWL) is a treatment option for all locations of renal and ureteric stones. We compared the results of SWL for lower pole renal stones with all other non-lower pole renal and ureteric stones during the same time period. Material and Methods: All SWL procedures were carried out as day case procedures by a mobile lithotripter from January 2012 to August 2013. The follow-up imaging was a combination of KUB X-ray or USS. Following SWL treatment, the stone free rate (SFR) was defined as ≤3 mm fragments. Results: A total of 148 patients with a mean age of 62 years underwent 201 procedures. Of the 201 procedures, 93 (46%) were for lower pole stones. The non-lower pole stones included upper pole (n = 36), mid pole (n = 40), renal pelvis (n = 10), PUJ (n = 8), mid ureter (n = 3), upper ureter (n = 5) and a combination of upper, middle and/or lower pole (n = 6). The mean stone size for lower pole stones (7.4 mm; range: 4-16 mm) was slightly smaller than non-lower pole stones (8 mm; range: 4-17 mm). The stone fragmentation was successful in 124 (62%) of patients. However, the SFR was statistically significantly better (P = 0.023) for non-lower pole stones 43 (40%) compared to lower pole stones 23 (25%). There were 9 (4%) minor complications and this was not significantly different in the two groups. Conclusions: Although SWL achieves a moderately high stone fragmentation rate with a low complication rate, the SFR is variable depending on the location of stone and the definition of SFR, with lower pole stones fairing significantly worse than stones in all other locations. PMID:25657543
Geraghty, Robert; Burr, Jacob; Simmonds, Nick; Somani, Bhaskar K
2015-01-01
Shock wave lithotripsy (SWL) is a treatment option for all locations of renal and ureteric stones. We compared the results of SWL for lower pole renal stones with all other non-lower pole renal and ureteric stones during the same time period. All SWL procedures were carried out as day case procedures by a mobile lithotripter from January 2012 to August 2013. The follow-up imaging was a combination of KUB X-ray or USS. Following SWL treatment, the stone free rate (SFR) was defined as ≤3 mm fragments. A total of 148 patients with a mean age of 62 years underwent 201 procedures. Of the 201 procedures, 93 (46%) were for lower pole stones. The non-lower pole stones included upper pole (n = 36), mid pole (n = 40), renal pelvis (n = 10), PUJ (n = 8), mid ureter (n = 3), upper ureter (n = 5) and a combination of upper, middle and/or lower pole (n = 6). The mean stone size for lower pole stones (7.4 mm; range: 4-16 mm) was slightly smaller than non-lower pole stones (8 mm; range: 4-17 mm). The stone fragmentation was successful in 124 (62%) of patients. However, the SFR was statistically significantly better (P = 0.023) for non-lower pole stones 43 (40%) compared to lower pole stones 23 (25%). There were 9 (4%) minor complications and this was not significantly different in the two groups. Although SWL achieves a moderately high stone fragmentation rate with a low complication rate, the SFR is variable depending on the location of stone and the definition of SFR, with lower pole stones fairing significantly worse than stones in all other locations.
The potential of wood-based composite poles
Todd F. Shupe; Cheng Piao; Chung Y. Hse
2009-01-01
Wood-based composite utility poles are receiving increasing attention in the North American pole market. This interest is being driven by many increasing factors such as increasing: (1) disposal costs of solid wood poles, (2) liability and environmental concerns with traditional means of disposal of solid wood poles, (3) cost and concerns of long-term...
Imai, Ayano; Oda, Yuriko; Seki, Shinobu; Nakagawa, Kiyotaka; Miyazawa, Teruo; Ueda, Fumitaka
2018-01-01
Severe fatigue can negatively affect quality of life, and oxidative stress may play a role in its mechanism. The aim of this study was to evaluate the effect of dietary supplementation of astaxanthin and sesamin (AS), strong food-derived antioxidants, on fatigue. Twenty-four healthy volunteers were supplemented with AS and placebo, each for four weeks. After each supplementation period, participants underwent tasks inducing mental and physical fatigue (visual display terminal task and ergometer task, respectively). Subjective fatigue was evaluated using a visual analogue scale during and after the mental and physical tasks, and daily subjective fatigue was evaluated by the Chalder fatigue questionnaire. Secondary outcomes included other subjective feelings, work efficiency, autonomic nerve activity, levels of an oxidative stress marker (plasma phosphatidylcholine hydroperoxide (PCOOH)) and safety. AS supplementation was associated with significantly improved recovery from mental fatigue compared with placebo. Increased PCOOH levels during mental and physical tasks were attenuated by AS supplementation. No differences between AS and placebo were detected in secondary outcomes, and no adverse effects of AS supplementation were observed. In conclusion, AS supplementation may be a candidate to promote recovery from mental fatigue which is experienced by many healthy people. PMID:29495607
Alcohol-induced physiological displacements and their effects on flight-related functions.
DOT National Transportation Integrated Search
1982-03-01
Tolerances of human subjects for orthostasis and physical work were determined at a simulated altitude of 3,048 m. Orthostasis was induced with a lower body negative pressure (LBNP) device and physical work was done on a pedal ergometer. Altitude was...
Eliassen, Håkon S; Hervig, Tor; Backlund, Sebastian; Sivertsen, Joar; Iversen, Vegard Vereide; Kristoffersen, Morten; Wengaard, Eivind; Gramstad, Arne; Fosse, Theodor; Bjerkvig, Christopher K; Apelseth, Torunn; Doughty, Heidi; Strandenes, Geir
2018-06-01
The success of implementing damage control resuscitation principles pre-hospital has been at the expense of several logistic burdens including the requirements for resupply, and the question of donor safety during the development of whole blood programs. Previous studies have reported effects on physical performance after blood donation; however, none have investigated the effects of blood donation on cognitive performance. We describe a prospective double-blinded, randomized, controlled study comprised of a battery of tests: three cognitive tests, and VO2max testing on a cycle ergometer. Testing was performed 7 days before blinded donation (baseline day), immediately after donation (Day 0), and 7 days (Day 7) after donation. The inclusion criteria included being active blood donors at the Haukeland University Hospital blood bank, where eligibility requirements were met on the testing days, and providing informed consent. Participants were randomized to either the experimental (n = 26) or control group (n = 31). Control group participants underwent a 'mock donation" in which a phlebotomy needle was placed but blood was not withdrawn. In the experimental group, mean ± SEM VO2max declined 6% from 41.35 ± 1.7 mLO2/(min·kg) at baseline to 39.0 ± 1.6 mLO2/(min·kg) on Day 0 and increased to 40.51 ± 1.5 mLO2/(min·kg) on Day 7. Comparable values in the control group were 42.1 ± 1.8 mLO2/(min·kg) at baseline, 41.6 ± 1.8 mLO2/(min·kg)) on Day 1 (1% decline from baseline), and 41.8 ± 1.8 mLO2/(min·kg) on Day 7.Comparing scores of all three cognitive tests on Day 0 and Day 7 showed no significant differences (p > 0.05). Our main findings are that executive cognitive and physical performances were well maintained after whole blood donation in healthy blood donors. The findings inform postdonation guidance on when donors may be required to return to duty. Randomized, controlled, double-blinded prospective trial study, level 1.
Low-pass filtering of noisy Schlumberger sounding curves. Part I: Theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patella, D.
1986-02-01
A contribution is given to the solution of the problem of filtering noise-degraded Schlumberger sounding curves. It is shown that the transformation to the pole-pole system is actually a smoothing operation that filters high-frequency noise. In the case of residual noise contamination in the transformed pole-pole curve, it is demonstrated that a subsequent application of a conventional rectangular low-pass filter, with cut-off frequency not less than the right-hand frequency limit of the main message pass-band, may satisfactorily solve the problem by leaving a pole-pole curve available for interpretation. An attempt is also made to understand the essential peculiarities of themore » pole-pole system as far as penetration depth, resolving power and selectivity power are concerned.« less
The Skylab Orbital Workshop Experiment Area
NASA Technical Reports Server (NTRS)
1972-01-01
This is a wide-angle view of the Orbital Workshop lower level experiment area. In center foreground is the ergometer bicycle. In center background is a litter chair for the Human Vestibular Function experiment (Skylab Experiment M131) and in right background is the Lower Body Negative Pressure System experiment (Skylab Experiment M092). The ergometer bicycle was used for metabolic activity experiments and exercise. The purpose of the Human Vestibular (irner ear) Function experiment was to examine the effect of weightlessness on man's sensitivity and susceptibility to motion rotation, and his perception of orientation. The Lower Body Negative Pressure experiment investigated the relationship between the zero gravity environment and cardiovascular deconditioning. A characteristic of cardiovascular deconditoning is the partial failure of the blood vessels resulting in the excessive pooling of the blood in the legs when a person assumes an erect posture in a gravity field. The Marshall Space Flight Center had the program management responsibility for the development of Skylab hardware and experiments.
Caloric and exercise requirements of space flight - Biostereometric results from Skylab
NASA Technical Reports Server (NTRS)
Whittle, M. W.
1979-01-01
The biostereometric study of the Skylab astronauts used stereophotogrammetry to make accurate three-dimensional measurements of body form, from which regional and total body volumes were derived. Volume changes in the thighs and calves, over the course of the flight, showed a high correlation with inflight exercise on the bicycle ergometer, and suggested that an exercise level of 80-100 W-min/d/kg lean body mass would be necessary to prevent inflight muscle atrophy. The bicycle ergometer is thus a relatively inefficient means of preventing leg muscle atrophy. Inflight caloric intake showed a high correlation with the change in volume of the buttocks, the abdomen, and the body as a whole, and suggested that a caloric intake of 47-51 kcal/d/kg lean body mass would be necessary to prevent a change in body fat. Only one of the astronauts exceeded this range and gained body fat; the group as a whole showed a mean fat loss of 1.2 kg.
STS-40 Mission Specialist (MS) Seddon on ergometer conducts Exp. No. 066
1991-06-14
STS040-211-019 (5-14 June 1991) --- Astride the bicycle ergometer, astronaut Rhea Seddon, mission specialist, breathes into the cardiovascular re-breathing unit during the exercise phase of an experiment. The investigation, In-flight Study of Cardiovascular Deconditioning (Experiment 066), was developed by Dr. Leon E. Farhi of the State University of New York in Buffalo. It focuses on the deconditioning of the heart and lungs and changes in cardiopulmonary function that occur upon return to Earth. By using non-invasive techniques of prolonged expiration and re-breathing, investigators can determine the amount of blood pumped out of the heart (cardiac output), the ease with which blood flows through all the vessels (total peripheral resistance), oxygen used and carbon dioxide released by the body, and lung function and volume changes. Measurements are made both while crew members are resting and while they pedal the exercise bicycle, as Dr. Seddon is doing here. This scene was photographed with a 35mm camera.
Charon's Size And Orbit From Double Stellar Occultations
NASA Astrophysics Data System (ADS)
Sicardy, Bruno; Braga-Ribas, F.; Widemann, T.; Jehin, E.; Gillon, M.; Manfroid, J.; Ortiz, J. L.; Morales, N.; Maury, A.; Assafin, M.; Camargo, J. I. B.; Vieira Martins, R.; Dias Oliveira, A.; Ramos Gomes, A., Jr.; Vanzi, L.; Leiva, R.; Young, L. A.; Buie, M. W.; Olkin, C. B.; Young, E. F.; Howell, R. R.; French, R. G.; Bianco, F. B.; Fulton, B. J.; Lister, T. A.; Bode, H. J.; Barnard, B.; Merritt, J. C.; Shoemaker, K.; Vengel, T.; Tholen, D. J.; Hall, T.; Reitsema, H. J.; Wasserman, L. H.; Go, C.
2012-10-01
Stellar occultations of a same star by both Pluto and Charon (double events) yield instantaneous relative positions of the two bodies projected in the plane of the sky, at 10km-level accuracy. Assuming a given pole orientation for Charon's orbit, double events provide the satellite plutocentric distance r at a given orbital longitude L (counted from the ascending node on J2000 mean equator), and finally, constraints on its orbit. A double event observed on 22 June 2008 provides r=19,564+/-14 km at L=153.483+/-0.071 deg. (Sicardy et al. 2011), while another double event observed on 4 June 2011 yields: r=19,586+/-15 km at L = 343.211+/-0.072 deg. (all error bars at 1-sigma level). These two positions are consistent with a circular orbit for Charon, with a semi-major axis of a=19,575+\\-10 km. This can be compared to the circular orbit found by Buie et al. (2012), based on Hubble Space Telescope data, with a=19,573+/-2 km. The 4 June 2011 stellar occultation provides 3 chords across Charon, from which a radius of Rc= 602.4+/-1.6 km is derived. This value can be compared to that obtained from the 11 July 2005 occultation: Rc= 606.0+/-1.5 km (Person et al. 2006) and Rc= 603.6+/-1.4 km (Sicardy et al. 2006). A third double event, observed on 23 June 2011 is under ongoing analysis, and will be presented. Buie et al. (2012), AJ 144, 15-34 (2012) Person et al, AJ 132, 1575-1580 (2006) Sicardy et al., Nature 439, 52-54 (2006) Sicardy et al., AJ 141, 67-83 (2011) B.S. thanks ANR "Beyond Neptune II". L.A.Y. acknowledges support by NASA, New Horizons and National Geographic grants. We thank B. Barnard, M.J. Brucker, J. Daily, C. Erikson, W. Fukunaga, C. Harlinten, C. Livermore, C. Nance, J.R. Regester, L. Salas, P. Tamblyn, R. Westhoff for help in the observations.
Effect of materials and manufacturing on the bending stiffness of vaulting poles
NASA Astrophysics Data System (ADS)
Davis, C. L.; Kukureka, S. N.
2012-09-01
The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP) composites. The lighter GFRP pole enabled the athletes to have a faster run-up, resulting in a greater take-off speed, giving them more kinetic energy to convert into potential energy and hence height. GFRP poles also have a much higher failure stress than bamboo, so the poles were engineered to bend under the load of the athlete, thereby storing elastic strain energy that can be released as the pole straightens, resulting in greater energy efficiency. The bending also allowed athletes to change their vaulting technique from a style that involved the body remaining almost upright during the vault to one where the athlete goes over the bar with their feet upwards. Modern vaulting poles can be made from GFRP and/or carbon fibre reinforced polymer (CFRP) composites. The addition of carbon fibres maintains the mechanical properties of the pole, but allows a reduction in the weight. The number and arrangement of the fibres determines the mechanical properties, in particular the bending stiffness. Vaulting poles are also designed for an individual athlete to take into account each athlete’s ability and physical characteristics. The poles are rated by ‘weight’ to allow athletes to select an appropriate pole for their ability. This paper will review the development of vaulting poles and the requirements to maximize performance. The properties (bending stiffness and pre-bend) and microstructure (fibre volume fraction and lay-up) of typical vaulting poles will be discussed. Originally published as Davis C L and Kukureka S N (2004) Effect of materials and manufacturing on the bending stiffness of vaulting poles The Engineering of Sport 5 ed M Hubbard, R D Mehta and J M Pallis (Sheffield: ISEA). Republished here with permission from ISEA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, G.; Abarbanel, H.; Carruthers, P.
If the current growth rate in the use of fossil fuels continues at 4.3% per year, then the CO/sub 2/ concentration in the atmosphere can be expected to double by about 2035 provided the current partition of CO/sub 2/ between the atmosphere, biosphere, and oceans is maintained as is the current mix of fuels. Slower rates of anticipated growth of energy use lead to a doubling of the carbon content of the atmosphere sometime in the period 2040 to 2060. This report addresses the questions of the sources of atmospheric CO/sub 2/; considers distribution of the present CO/sub 2/ amongmore » the atmospheric, oceanic, and biospheric reservoir; and assesses the impact on climate as reflected by the average ground temperature at each latitude of significant increases in atmospheric CO/sub 2/. An analytic model of the atmosphere was constructed (JASON Climate Model). Calculation with this zonally averaged model shows an increase of average surface temperature of 2.4/sup 0/ for a doubling of CO/sub 2/. The equatorial temperature increases by 0.7/sup 0/K, while the poles warm up by 10 to 12/sup 0/K. The warming of climate will not necessarily lead to improved living conditions everywhere. Changes in sea level, in agricultural productivity, and in water availability can be anticipated, but the dimensions of their economic, political, or social consequences can not.« less
Sectional Pole for Measuring Tree Heights
R. H. Brendemuehl; James B. Baker
1965-01-01
A sectional aluminum pole designed by the Silviculture Laboratory at Marianna, Florida, has proved useful for measuring tree heights. It is more convenient than a sectional bamboo pole 1 or a telescoping fiberglass pole. A tree 5 to 30 feet in height can be measured to the nearest tenth of a foot in 30 seconds. The pole is constructed of low-cost, readily available...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
... also involved placing a pole in the hole and attaching transformers and other items to the pole... industries, including placing utility poles in the ground and attaching transformers and other equipment to...- mount transformers on the ground as part of the same power system as the poles. While the pole work is...
Mechanical properties of small-scale wood laminated composite poles
Cheng Piao; Todd F. Shupe; Chung Y. Hse
2004-01-01
Power companies in the United States consume millions of solid wood poles every year. These poles are from high-valued trees that are becoming more expensive and less available. wood laminated composite poles (LCP) are a novel alternative to solid wood poles. LCP consists of trapezoid wood strips that are bonded by a synthetic resin. The wood strips can be made from...
Shadow poles in coupled-channel problems calculated with the Berggren basis
NASA Astrophysics Data System (ADS)
Id Betan, R. M.; Kruppa, A. T.; Vertse, T.
2018-02-01
Background: In coupled-channels models the poles of the scattering S matrix are located on different Riemann sheets. Physical observables are affected mainly by poles closest to the physical region but sometimes shadow poles have considerable effect too. Purpose: The purpose of this paper is to show that in coupled-channels problems all poles of the S matrix can be located by an expansion in terms of a properly constructed complex-energy basis. Method: The Berggren basis is used for expanding the coupled-channels solutions. Results: The locations of the poles of the S matrix for the Cox potential, constructed for coupled-channels problems, were numerically calculated and compared with the exact ones. In a nuclear physics application the Jπ=3 /2+ resonant poles of 5He were calculated in a phenomenological two-channel model. The properties of both the normal and shadow resonances agree with previous findings. Conclusions: We have shown that, with an appropriately chosen Berggren basis, all poles of the S matrix including the shadow poles can be determined. We have found that the shadow pole of 5He migrates between Riemann sheets if the coupling strength is varied.
Whitson exercises on the CEVIS in the U.S. Laboratory during Joint Operations
2008-03-23
S123-E-008961 (23 March 2008) --- Astronaut Peggy Whitson, Expedition 16 commander, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station while Space Shuttle Endeavour remains docked with the station.
FE Anderson exercising on the CEVIS during STS-118/Expedition 15 Joint Operations
2007-08-16
S118-E-07657 (16 Aug. 2007) --- Astronaut Clayton Anderson, Expedition 15 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station while Space Shuttle Endeavour remains docked with the station.
Effect of Toe Clips During Bicycle Ergometry on VO2 max.
ERIC Educational Resources Information Center
Moffat, Roger S.; Sparling, Phillip B.
1985-01-01
Eight men participated in three randomized maximal oxygen uptake tests to investigate the hypothesis that the use of toe clips on bicycle ergometers produced a higher VO2 max. No significant difference in mean VO2 max or performance time was observed. (Author/MT)
Endometrial Carcinomas with POLE Exonuclease Domain Mutations Have a Favorable Prognosis.
McConechy, Melissa K; Talhouk, Aline; Leung, Samuel; Chiu, Derek; Yang, Winnie; Senz, Janine; Reha-Krantz, Linda J; Lee, Cheng-Han; Huntsman, David G; Gilks, C Blake; McAlpine, Jessica N
2016-06-15
The aim of this study was to confirm the prognostic significance of POLE exonuclease domain mutations (EDM) in endometrial carcinoma patients. In addition, the effect of treatment on POLE-mutated tumors was assessed. A retrospective patient cohort of 496 endometrial carcinoma patients was identified for targeted sequencing of the POLE exonuclease domain, yielding 406 evaluable tumors. Univariable and multivariable analyses were performed to determine the effect of POLE mutation status on progression-free survival (PFS), disease-specific survival (DSS), and overall survival (OS). Combining results from eight studies in a meta-analysis, we computed pooled HR for PFS, DSS, and OS. POLE EDMs were identified in 39 of 406 (9.6%) endometrial carcinomas. Women with POLE-mutated endometrial carcinomas were younger, with stage I (92%) tumors, grade 3 (62%), endometrioid histology (82%), and frequent (49%) lymphovascular invasion. In univariable analysis, POLE-mutated endometrial carcinomas had significantly improved outcomes compared with patients with no EDMs for PFS, DSS, and OS. In multivariable analysis, POLE EDMs were only significantly associated with improved PFS. The effect of adjuvant treatment on POLE-mutated cases could not be determined conclusively; however, both treated and untreated patients with POLE EDMs had good outcomes. Meta-analysis revealed an association between POLE EDMs and improved PFS and DSS with pooled HRs 0.34 [95% confidence interval (CI), 0.15-0.73] and 0.35 (95% CI, 0.13-0.92), respectively. POLE EDMs are prognostic markers associated with excellent outcomes for endometrial carcinoma patients. Further investigation is needed to conclusively determine if treatment is necessary for this group of women. Clin Cancer Res; 22(12); 2865-73. ©2016 AACR. ©2016 American Association for Cancer Research.
Magnetic field generated by lightning protection system
NASA Astrophysics Data System (ADS)
Geri, A.; Veca, G. M.
1988-04-01
A lightning protection system for today's civil buildings must be electromagnetically compatible with the electronic equipment present in the building. This paper highlights a mathematic model which analyzes the electromagnetic effects in the environment in which the lightning protection system is. This model is developed by means of finite elements of an electrical circuit where each element is represented by a double pole circuit according to the trapezoidal algorithm developed using the finite difference method. It is thus possible to analyze the electromagnetic phenomena associated with the transient effects created by the lightning stroke even for a high-intensity current. Referring to an elementary system comprised of an air terminal, a down conductor, and a ground terminal, numerical results are here laid out.
Design of a Modular E-Core Flux Concentrating Axial Flux Machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Husain, Tausif; Sozer, Yilmaz; Husain, Iqbal
2015-09-02
In this paper a novel E-Core axial flux machine is proposed. The machine has a double stator-single rotor configuration with flux concentrating ferrite magnets, and pole windings across each leg of an E-Core stator. E-Core stators with the proposed flux-concentrating rotor arrangement result in better magnet utilization and higher torque density. The machine also has a modular structure facilitating simpler construction. This paper presents a single phase and a three-phase version of the E-Core machine. Case study for a 1.1 kW, 400 rpm machine for both the single phase and three-phase axial flux machine is presented. The results are verifiedmore » through 3D finite element analysis.« less
The diameter of Pallas from its occultation of SAO 85009
NASA Technical Reports Server (NTRS)
Wasserman, L. H.; Millis, R. L.; Franz, O. G.; Bowell, E.; Giclas, H. L.; Martin, L. J.; Elliot, J. L.; Dunham, E.; Mink, D.; White, N. M.
1979-01-01
The May 29, 1978, occultation of SAO 85009 by Pallas was observed photoelectrically at seven widely spaced sites. The observations are well represented by an elliptical apparent limb profile having semimajor and semiminor axes of 279.5 + or - 2.9 and 262.7 + or - 4.5 km, respectively. Combining these results with published information on the light curve and rotational pole position, Pallas's mean diameter is found to be 538 + or - 12 km, which yields a mean density for Pallas of 2.8 + or - 0.5 g/cu cm and a visual geometric albedo of 0.103 + or - 0.005. The diameter of Pallas as determined from this occultation is significantly smaller than the values derived by radiometric, polarimetric, and double-image techniques.
Cmos spdt switch for wlan applications
NASA Astrophysics Data System (ADS)
Bhuiyan, M. A. S.; Reaz, M. B. I.; Rahman, L. F.; Minhad, K. N.
2015-04-01
WLAN has become an essential part of our today's life. The advancement of CMOS technology let the researchers contribute low power, size and cost effective WLAN devices. This paper proposes a single pole double through transmit/receive (T/R) switch for WLAN applications in 0.13 μm CMOS technology. The proposed switch exhibit 1.36 dB insertion loss, 25.3 dB isolation and 24.3 dBm power handling capacity. Moreover, it only dissipates 786.7 nW power per cycle. The switch utilizes only transistor aspect ratio optimization and resistive body floating technique to achieve such desired performance. In this design the use of bulky inductor and capacitor is avoided to evade imposition of unwanted nonlinearities to the communication signal.
Optical properties of anthocyanins in the gas phase
NASA Astrophysics Data System (ADS)
Ge, Xiaochuan; Calzolari, Arrigo; Baroni, Stefano
2015-01-01
The gas-phase optical properties of the six most common anthocyanins are studied using time-dependent density-functional theory. Different anthocyanins are classified into three groups, according to the number of low-frequency peaks displayed in the UV-vis spectrum. This behavior is analyzed in terms of one-electron transitions and interaction effects, the latter being rationalized using a suitable double-pole model. Moving from PBE to hybrid exchange-correlation functionals results in a hypsochromic shift of the optical gap. While the colors thus predicted do not quite match those observed in solution, thus highlighting the importance of solvation effects, adoption of hybrid functionals remarkably determines a greater chromatic uniformity of different molecules, in qualitative agreement with experimental evidence in acidic solutions.
Van Gool, Inge C; Ubachs, Jef E H; Stelloo, Ellen; de Kroon, Cor D; Goeman, Jelle J; Smit, Vincent T H B M; Creutzberg, Carien L; Bosse, Tjalling
2018-01-01
POLE exonuclease domain mutations identify a subset of endometrial cancer (EC) patients with an excellent prognosis. The use of this biomarker has been suggested to refine adjuvant treatment decisions, but the necessary sequencing is not widely performed and is relatively expensive. Therefore, we aimed to identify histopathological and immunohistochemical characteristics to aid in the detection of POLE-mutant ECs. Fifty-one POLE-mutant endometrioid, 67 POLE-wild-type endometrioid and 15 POLE-wild-type serous ECs were included (total N = 133). An expert gynaecopathologist, blinded to molecular features, evaluated each case (two or more slides) for 16 morphological characteristics. Immunohistochemistry was performed for p53, p16, MLH1, MSH2, MSH6, and PMS2. POLE-mutant ECs were characterised by a prominent immune infiltrate: 80% showed peritumoral lymphocytes and 59% showed tumour-infiltrating lymphocytes, as compared with 43% and 28% of POLE-wild-type endometrioid ECs, and 27% and 13% of their serous counterparts (P < 0.01, all comparisons). Of POLE-mutant ECs, 33% contained tumour giant cells; this proportion was significantly higher than that in POLE-wild-type endometrioid ECs (10%; P = 0.003), but not significantly different from that in serous ECs (53%). Serous-like features were as often (focally) present in POLE-mutant as in POLE-wild-type endometrioid ECs (6-24%, depending on the feature). The majority of POLE-mutant ECs showed wild-type p53 (86%), negative/focal p16 (82%) and normal mismatch repair protein expression (90%). A simple combination of morphological and immunohistochemical characteristics (tumour type, grade, peritumoral lymphocytes, MLH1, and p53 expression) can assist in prescreening for POLE exonuclease domain mutations in EC, increasing the probability of a mutation being detected from 7% to 33%. This facilitates the use of this important prognostic biomarker in routine pathology. © 2017 John Wiley & Sons Ltd.
2012-11-02
As spring progresses at the south pole, the surface reacts to the change of season. This image from NASA 2001 Mars Odyssey spacecraft shows a region of the south pole that is monitored throughout spring, summer, and fall at the south pole.
Large optical second-order nonlinearity of poled WO3-TeO2 glass.
Tanaka, K; Narazaki, A; Hirao, K
2000-02-15
Second-harmonic generation, one of the second-order nonlinear optical properties of thermally and electrically poled WO>(3)-TeO>(2) glasses, has been examined. We poled glass samples with two thicknesses (0.60 and 0.86 mm) at various temperatures to explore the effects of external electric field strength and poling temperature on second-order nonlinearity. The dependence of second-harmonic intensity on the poling temperature is maximum at a specific poling temperature. A second-order nonlinear susceptibility of 2.1 pm/V was attained for the 0.60-mm-thick glass poled at 250 degrees C. This value is fairly large compared with those for poled silica and tellurite glasses reported thus far. We speculate that the large third-order nonlinear susceptibility of WO>(3)- TeO>(2) glasses gives rise to the large second-order nonlinearity by means of a X((2)) = 3X((3)) E(dc) process.
78 FR 32110 - Cranes and Derricks in Construction: Revising the Exemption for Digger Derricks
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-29
... poles in the ground and attaching transformers and other equipment to the poles (see 29 CFR 1400(c)(4... attaching transformers and other items to the pole (see 75 FR 47906, 47924-47926, and 48136 (Aug. 9, 2010... transformers on the ground as part of the same power system as the poles. While the pole work is exempt under...
Polε Instability Drives Replication Stress, Abnormal Development, and Tumorigenesis.
Bellelli, Roberto; Borel, Valerie; Logan, Clare; Svendsen, Jennifer; Cox, Danielle E; Nye, Emma; Metcalfe, Kay; O'Connell, Susan M; Stamp, Gordon; Flynn, Helen R; Snijders, Ambrosius P; Lassailly, François; Jackson, Andrew; Boulton, Simon J
2018-05-17
DNA polymerase ε (POLE) is a four-subunit complex and the major leading strand polymerase in eukaryotes. Budding yeast orthologs of POLE3 and POLE4 promote Polε processivity in vitro but are dispensable for viability in vivo. Here, we report that POLE4 deficiency in mice destabilizes the entire Polε complex, leading to embryonic lethality in inbred strains and extensive developmental abnormalities, leukopenia, and tumor predisposition in outbred strains. Comparable phenotypes of growth retardation and immunodeficiency are also observed in human patients harboring destabilizing mutations in POLE1. In both Pole4 -/- mouse and POLE1 mutant human cells, Polε hypomorphy is associated with replication stress and p53 activation, which we attribute to inefficient replication origin firing. Strikingly, removing p53 is sufficient to rescue embryonic lethality and all developmental abnormalities in Pole4 null mice. However, Pole4 -/- p53 +/- mice exhibit accelerated tumorigenesis, revealing an important role for controlled CMG and origin activation in normal development and tumor prevention. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.
Anisotropic distribution of orbit poles of binary asteroids
NASA Astrophysics Data System (ADS)
Pravec, P.; Scheirich, P.; Vokrouhlický, D.; Harris, A. W.; Kusnirak, P.; Hornoch, K.; Pray, D. P.; Higgins, D.; Galád, A.; Világi, J.; Gajdos, S.; Kornos, L.; Oey, J.; Husárik, M.; Cooney, W. R.; Gross, J.; Terrell, D.; Durkee, R.; Pollock, J.; Reichart, D.; Ivarsen, K.; Haislip, J.; Lacluyze, A.; Krugly, Y. N.; Gaftonyuk, N.; Dyvig, R.; Reddy, V.; Stephens, R. D.; Chiorny, V.; Vaduvescu, O.; Longa, P.; Tudorica, A.; Warner, B. D.; Masi, G.; Brinsfield, J.; Gonçalves, R.; Brown, P.; Krzeminski, Z.; Gerashchenko, O.; Marchis, F.
2011-10-01
Our photometric observations of 18 mainbelt binary systems in more than one apparition revealed a strikingly high number of 15 having positively re-observed mutual events in the return apparitions. Our simulations of the survey showed that the data strongly suggest that poles of mutual orbits between components of binary asteroids are not distributed randomly: The null hypothesis of the isotropic distribution of orbit poles is rejected at a confidence level greater than 99.99%. Binary orbit poles concentrate at high ecliptic latitudes, within 30° of the poles of the ecliptic. We propose that the binary orbit poles oriented preferentially up/down-right are due to formation of small binary systems by rotational fission of critically spinning parent bodies with poles near the YORP asymptotic states with obliquities near 0 and 180°. An alternative process of elimination of binaries with poles closer to the ecliptic by the Kozai dynamics of gravitational perturbations from the sun does not explain the observed orbit pole concentration as in the close asteroid binary systems the J2 perturbation due to the primary dominates the solar-tide effect.
Anderson-Furgeson, James C.; Zupan, John R.; Grangeon, Romain
2016-01-01
ABSTRACT Agrobacterium tumefaciens is a rod-shaped Gram-negative bacterium that elongates by unipolar addition of new cell envelope material. Approaching cell division, the growth pole transitions to a nongrowing old pole, and the division site creates new growth poles in sibling cells. The A. tumefaciens homolog of the Caulobacter crescentus polar organizing protein PopZ localizes specifically to growth poles. In contrast, the A. tumefaciens homolog of the C. crescentus polar organelle development protein PodJ localizes to the old pole early in the cell cycle and accumulates at the growth pole as the cell cycle proceeds. FtsA and FtsZ also localize to the growth pole for most of the cell cycle prior to Z-ring formation. To further characterize the function of polar localizing proteins, we created a deletion of A. tumefaciens podJ (podJAt). ΔpodJAt cells display ectopic growth poles (branching), growth poles that fail to transition to an old pole, and elongated cells that fail to divide. In ΔpodJAt cells, A. tumefaciens PopZ-green fluorescent protein (PopZAt-GFP) persists at nontransitioning growth poles postdivision and also localizes to ectopic growth poles, as expected for a growth-pole-specific factor. Even though GFP-PodJAt does not localize to the midcell in the wild type, deletion of podJAt impacts localization, stability, and function of Z-rings as assayed by localization of FtsA-GFP and FtsZ-GFP. Z-ring defects are further evidenced by minicell production. Together, these data indicate that PodJAt is a critical factor for polar growth and that ΔpodJAt cells display a cell division phenotype, likely because the growth pole cannot transition to an old pole. IMPORTANCE How rod-shaped prokaryotes develop and maintain shape is complicated by the fact that at least two distinct species-specific growth modes exist: uniform sidewall insertion of cell envelope material, characterized in model organisms such as Escherichia coli, and unipolar growth, which occurs in several alphaproteobacteria, including Agrobacterium tumefaciens. Essential components for unipolar growth are largely uncharacterized, and the mechanism constraining growth to one pole of a wild-type cell is unknown. Here, we report that the deletion of a polar development gene, podJAt, results in cells exhibiting ectopic polar growth, including multiple growth poles and aberrant localization of cell division and polar growth-associated proteins. These data suggest that PodJAt is a critical factor in normal polar growth and impacts cell division in A. tumefaciens. PMID:27137498
Eyharts Exercises on the CEVIS in the US Lab
2008-03-16
ISS016-E-032805 (16 March 2008) --- European Space Agency (ESA) astronaut Leopold Eyharts, Expedition 16 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station while Space Shuttle Endeavour (STS-123) remains docked with the station.
Williams during the PFE-OUM Experiment in the US Lab during Expedition 15
2007-05-24
ISS015-E-09461 (24 May 2007) --- Astronaut Sunita L. Williams, Expedition 15 flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) during a Periodic Fitness Evaluation with Oxygen Uptake Measurement (PFE-OUM) experiment in the Destiny laboratory of the International Space Station.
Zhang, Rubin; Zhan, Likui; Sun, Shaoming; Peng, Wei; Sun, Yining
2017-01-01
The maximum oxygen uptake (V̇O2 max), determined from graded maximal or submaximal exercise tests, is used to classify the cardiorespiratory fitness level of individuals. The purpose of this study was to examine the validity and reliability of the YMCA submaximal exercise test protocol performed on a newly-designed rectilinear stepping ergometer (RSE) that used up and down reciprocating vertical motion in place of conventional circular motion and giving precise measurement of workload, to determine V̇O2 max in young healthy male adults. Thirty-two young healthy male adults (32 males; age range: 20-35 years; height: 1.75 ± 0.05 m; weight: 67.5 ± 8.6 kg) firstly participated in a maximal-effort graded exercise test using a cycle ergometer (CE) to directly obtain measured V̇O2 max. Subjects then completed the progressive multistage test on the RSE beginning at 50W and including additional stages of 70, 90, 110, 130, and 150W, and the RSE YMCA submaximal test consisting of a workload increase every 3 minutes until the termination criterion was reached. A metabolic equation was derived from the RSE multistage exercise test to predict oxygen consumption (V̇O2) from power output (W) during the submaximal exercise test (V̇O2 (mL·min-1 )=12.4 ×W(watts)+3.5 mL·kg-1·min-1×M+160mL·min-1, R2= 0.91, standard error of the estimate (SEE) = 134.8mL·min-1). A high correlation was observed between the RSE YMCA estimated V̇O2 max and the CE measured V̇O2 max (r=0.87). The mean difference between estimated and measured V̇O2 max was 2.5 mL·kg-1·min-1, with an SEE of 3.55 mL·kg-1·min-1. The data suggest that the RSE YMCA submaximal exercise test is valid for predicting V̇O2 max in young healthy male adults. The findings show that the rectilinear stepping exercise is an effective submaximal exercise for predicting V̇O2 max. The newly-designed RSE may be potentially further developed as an alternative ergometer for assessing cardiorespiratory fitness and the promotion of personalized health interventions for health care professionals. Key points The rectilinear stepping exercise is a simple modality of exercise, which requires only up and down movements of the legs. It overcomes the mechanical dead centers of circular motion and is mechanically efficient. It is potentially applicable to a large group of populations. The RSE gives an accurate measurement of power output and ensures a constant power output independent of stepping cadence. The RSE submaximal exercise test is valid and feasible for estimating V̇O2 max in young healthy male adults compared with the CE maximal exercise test. The rectilinear stepping exercise is an effective submaximal exercise mode for predicting V̇O2 max. The RSE designed for this study may be potentially developed as a new and alternative ergometer to assess cardiorespiratory fitness and could be used in the future by healthcare professionals to promote personalized health interventions. PMID:28912653
A LINE POLE 20, STUBBED HISTORIC POLE WITH ORIGINAL GLASS ...
A LINE POLE 20, STUBBED HISTORIC POLE WITH ORIGINAL GLASS PIN-TYPE INSULATORS AND INTACT COMMUNICATION LINE CROSS ARM. VIEW TO WEST. - Mystic Lake Hydroelectric Facility, Electric Transmission A Line, Along West Rosebud Creek, Fishtail, Stillwater County, MT
Strong permanent magnet-assisted electromagnetic undulator
Halbach, Klaus
1988-01-01
This invention discloses an improved undulator comprising a plurality of electromagnet poles located along opposite sides of a particle beam axis with alternate north and south poles on each side of the beam to cause the beam to wiggle or undulate as it travels generally along the beam axis and permanent magnets spaced adjacent the electromagnetic poles on each side of the axis of said particle beam in an orientation sufficient to reduce the saturation of the electromagnet poles whereby the field strength of the electromagnet poles can be increased beyond the normal saturation levels of the electromagnetic poles.
A strong permanent magnet-assisted electromagnetic undulator
Halbach, K.
1987-01-30
This invention discloses an improved undulator comprising a plurality of electromagnet poles located along opposite sides of a particle beam axis with alternate north and south poles on each side of the beam to cause the beam to wiggle or undulate as it travels generally along the beam axis and permanent magnets spaced adjacent the electromagnetic poles on each side of the axis of said particle beam in an orientation sufficient to reduce the saturation of the electromagnet poles whereby the field strength of the electromagnet poles can be increased beyond the normal saturation levels of the electromagnetic poles. 4 figs.
Design and evaluation of large scale pultruded fiberglass tubular structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
O`Toole, B.J.
1994-12-31
Large solid wood structures have been used in structural applications such as utility poles and marine pilings for a long time. A pultruded fiberglass reinforced polymer composite utility pole has been designed by the Composite Power Corporation of Las Vegas, Nevada which meets or exceeds the wood pole strength standards. This type of pole has many advantages over traditional wood, metal or concrete poles including: lighter weight, easier to climb and service, better dielectric and fire resistance properties, and it is more environmentally sound than treated wood poles. Utility crossarms, other attachments, and climbing devices are secured to grooves whichmore » run the entire length of the pole so there is no need to drill holes or wear spiked boots which would compromise the strength of the pole. Bending and torsion experiments have been conducted to determine if the present design meets the strength requirements of a forty foot Class one wood pole. Initial results of the composite pole tests showed a 17 percent advantage in bending strength, a 449 percent advantage in strength due to a vertical load applied to a crossarm, and a 43 percent advantage in twisting strength. Plans for further material characterization experiments and detailed stress and failure analysis are discussed.« less
Adapting Growth Pole Theory to Community College Development.
ERIC Educational Resources Information Center
Brumbach, Mary A.
2002-01-01
Explains growth pole theory, which is the theory that growth manifests itself at poles of growth, rather than everywhere at once. Applies this theory to community college development, and offers advice for implementing growth poles by taking an entrepreneurial approach to education. (NB)
NASA Astrophysics Data System (ADS)
Bullen, P. S.; Huang, H.-C.; Yang, H.; Dadap, J. I.; Kymissis, I.; Osgood, R. M.
2016-07-01
The domain structure of poled deeply thinned lithium niobate is investigated as a function of sample thickness. Free-standing samples of thickness from 25 to 500 μm are prepared by a multiple-cycle polish and annealing procedure and then periodically poled. Using these samples and employing micro-Raman scattering and scanning electron, atomic force, and optical microscopy together, the domain broadening and poling voltage are found to vary in a regular and significant manner. The poled domains show a reduction in width spreading of 38% as the sample thickness is reduced from 500 to 25 μm. Micro-Raman probe measurements verify the quality and the uniformity of the poled domains and provide insight into their thickness-dependent poling contrast.
NASA Technical Reports Server (NTRS)
Watson, Michael D.; Ashley, Paul R.; Abushagur, Mustafa
2004-01-01
A charge density and current density model of a waveguide system has been developed to explore the effects of electric field electrode poling. An optical waveguide may be modeled during poling by considering the dielectric charge distribution, polarization charge distribution, and conduction charge generated by the poling field. These charge distributions are the source of poling current densities. The model shows that boundary charge current density and polarization current density are the major source of currents measured during poling and thermally stimulated discharge These charge distributions provide insight into the poling mechanisms and are directly related to E(sub A), and, alpha(sub r). Initial comparisons with experimental data show excellent correlation to the model results.
Development of design specifications, details and design criteria for traffic light poles
DOT National Transportation Integrated Search
2006-09-01
Current rules and fabrication methods employed in the design of traffic light poles do not adequately address fatigue and fracture issues associated with the connection of mast arms to the vertical poles and the connection of the poles to the foundat...
View of worlds tallest totem pole, 136.5 feet tall. First ...
View of worlds tallest totem pole, 136.5 feet tall. First potlatch pole since 1904. Dedicated to all things and all peoples of southeast Alaska, 1971. Oct potlatch, looking northwest - Kake Salmon Cannery, Totem Pole, Kake, Wrangell-Petersburg Census Area, AK
In Situ Poling and Imidization of Amorphous Piezoelectric Polyimides
NASA Technical Reports Server (NTRS)
Park, Cheol; Ounaies, Zoubeida; Wise, Kristopher E.; Harrison, Joycelyn S.; Bushnell, Dennis M. (Technical Monitor)
2002-01-01
An amorphous piezoelectric polyimide containing polar functional groups has been developed using a combination of experimental and molecular modeling for potential use in high temperature applications. This amorphous polyimide, (Beta-CN)APB/ODPA, has exhibited good thermal stability and piezoelectric response at temperatures up to 150C. Density functional calculations predicted that a partially cured amic acid (open imide ring) possesses a dipole moment four times larger than the fully imidized closed ring. In situ poling and imidization of the partially cured (Beta-CN)APB/ODPA, was studied in an attempt to maximize the degree of dipolar orientation and the resultant piezoelectric response. A positive corona poling was used to minimize localized arcing during poling and to allow use of higher poling fields without dielectric breakdown. The dielectric relaxation strength, remanent polarization, and piezoelectric response were evaluated as a function of the poling profile. The partially cured, corona poled polymers exhibited higher dielectric relaxation strength (delta varepsilon), remanent polarization (Pr) and piezoelectric strain coefficient (d33) than the fully cured, conventionally poled ones.
Development of Mini-pole Superconducting Undulator
NASA Astrophysics Data System (ADS)
Jan, J. C.; Hwang, C. S.; Lin, P. H.; Chang, C. H.; Lin, F. Y.
2007-01-01
A mini-pole superconducting undulator with a 15mm period length (SU15) was developed at the National Synchrotron Radiation Research Center (NSRRC). The coil was wound by a superconducting (SC) NbTi wire with small dimensions and low Cu/SC ratio. The design field strength of SU15 with 158turns/pole was 1.4T at 215A, and the magnet gap was 5.6 mm. Extra trim coils and poles are mounted on the main iron pole. The trim coils directly compensate for the strength error of the peak field. The prototype racetrack iron pole was fabricated via electric discharge machining to produce a complete set of 40-poles. The coil was impregnated by epoxy and wrapped in Kapton to maintain insulation between coil and iron pole. A substitution beam duct was built and assembled with the magnet array and tested in the test Dewar. The conceptual design of bath liquid helium (LHe) cryostat has to tolerate more image current and radiation heating on the beam duct.
Six pole/eight pole single-phase motor
Kirschbaum, Herbert S.
1984-01-01
A single phase alternating current electric motor is provided with a main stator winding having two coil groups which are connected to form eight poles for eight-pole operation and to form six poles for six-pole operation. Each group contains four series connected coil elements with each element spanning approximately one-seventh of the periphery of the machine. The coil groups are spaced 180 mechanical degrees apart such that each end coil of one group overlaps one of the end coils of the other group. An auxiliary stator winding having two coil groups with the same relative angular displacement as the main stator winding coil groups is included.
Current superimposition variable flux reluctance motor with 8 salient poles
NASA Astrophysics Data System (ADS)
Takahara, Kazuaki; Hirata, Katsuhiro; Niguchi, Noboru; Kohara, Akira
2017-12-01
We propose a current superimposition variable flux reluctance motor for a traction motor of electric vehicles and hybrid electric vehicles, which consists of 10 salient poles in the rotor and 12 slots in the stator. However, iron losses of this motor in high rotation speed ranges is large because the number of salient poles is large. In this paper, we propose a current superimposition variable flux reluctance motor that consists of 8 salient poles and 12 slots. The characteristics of the 10-pole-12-slot and 8-pole-12-slot current superimposition variable flux reluctance motors are compared using finite element analysis under vector control.
Six pole/eight pole single-phase motor
Kirschbaum, H.S.
1984-07-31
A single phase alternating current electric motor is provided with a main stator winding having two coil groups which are connected to form eight poles for eight-pole operation and to form six poles for six-pole operation. Each group contains four series connected coil elements with each element spanning approximately one-seventh of the periphery of the machine. The coil groups are spaced 180 mechanical degrees apart such that each end coil of one group overlaps one of the end coils of the other group. An auxiliary stator winding having two coil groups with the same relative angular displacement as the main stator winding coil groups is included. 10 figs.
Vibration Monitoring of Power Distribution Poles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark Scott; Gail Heath; John Svoboda
2006-04-01
Some of the most visible and least monitored elements of our national security infrastructure are the poles and towers used for the distribution of our nation’s electrical power. Issues surrounding these elements within the United States include safety such as unauthorized climbing and access, vandalism such as nut/bolt removal or destructive small arms fire, and major vandalism such as the downing of power poles and towers by the cutting of the poles with a chainsaw or torches. The Idaho National Laboratory (INL) has an ongoing research program working to develop inexpensive and sensitive sensor platforms for the monitoring and characterizationmore » of damage to the power distribution infrastructure. This presentation covers the results from the instrumentation of a variety of power poles and wires with geophone assemblies and the recording of vibration data when power poles were subjected to a variety of stimuli. Initial results indicate that, for the majority of attacks against power poles, the resulting signal can be seen not only on the targeted pole but on sensors several poles away in the distribution network and a distributed sensor system can be used to monitor remote and critical structures.« less
Converting point-wise nuclear cross sections to pole representation using regularized vector fitting
NASA Astrophysics Data System (ADS)
Peng, Xingjie; Ducru, Pablo; Liu, Shichang; Forget, Benoit; Liang, Jingang; Smith, Kord
2018-03-01
Direct Doppler broadening of nuclear cross sections in Monte Carlo codes has been widely sought for coupled reactor simulations. One recent approach proposed analytical broadening using a pole representation of the commonly used resonance models and the introduction of a local windowing scheme to improve performance (Hwang, 1987; Forget et al., 2014; Josey et al., 2015, 2016). This pole representation has been achieved in the past by converting resonance parameters in the evaluation nuclear data library into poles and residues. However, cross sections of some isotopes are only provided as point-wise data in ENDF/B-VII.1 library. To convert these isotopes to pole representation, a recent approach has been proposed using the relaxed vector fitting (RVF) algorithm (Gustavsen and Semlyen, 1999; Gustavsen, 2006; Liu et al., 2018). This approach however needs to specify ahead of time the number of poles. This article addresses this issue by adding a poles and residues filtering step to the RVF procedure. This regularized VF (ReV-Fit) algorithm is shown to efficiently converge the poles close to the physical ones, eliminating most of the superfluous poles, and thus enabling the conversion of point-wise nuclear cross sections.
Alfimov, V; Aldahan, A; Possnert, G; Winsor, P
2004-12-01
Variation in the concentrations of iodine-129 (129I, T1/2=15.7 Myr), a low-level radioactive component of nuclear fuel waste, is documented in surface waters and depth profiles collected during 2001 along a transect from the Norwegian Coastal Current to the North Pole. The surface waters near the Norwegian coast are found to have 20 times higher 129I concentration than the surface waters of the Arctic Ocean. The depth profiles of 129I taken in the Arctic Ocean reveal a sharp decline in the concentration to a depth of about 300-500 m followed by a weaker gradient extending down to the bottom. A twofold increase in the 129I concentration is observed in the upper 1000 m since 1996. Based on known estimates of marine transient time from the release sources (the nuclear reprocessing facilities at La Hague, France, and Sellafield, UK), a doubling in the 129I inventory of the top 1000 m of the Arctic Ocean is expected to occur between the years 2001 and 2006. As 129I of polar mixed layer and Atlantic layer of the Arctic Ocean is ventilated by the East Greenland Current into the Nordic Seas and North Atlantic Ocean, further dispersal and increase of the isotope concentration in these regions will be encountered in the near future.
Process support compressor motor electromagnetic design summary
NASA Astrophysics Data System (ADS)
Bailey, J. M.
1987-03-01
A 30-hp, 15,000-rpm, permanent magnet motor has been designed and is now being built. The direct drive motor has 72 slots and eight poles. Using A. O. Smith Magnetic, a flux plot was obtained and the flux density throughout one pole pitch has been determined. The poles are connected in a four-pole series, parallel WYE. Each pole requires 30 A for a total per phase current of 60 A. The torque capability is 2638 oz-in.
Möckel, Frank; Hoffmann, Gerd; Obermüller, Roy; Drobnik, Wolfgang; Schmitz, Gerd
2006-01-01
Aim of the study: Investigation, whether water-filtered infrared-A (wIRA) irradiation during moderate bicycle ergometer endurance exercise has effects especially on local fat reduction and on weight reduction beyond the effects of ergometer exercise alone. Methods: Randomised controlled study with 40 obese females (BMI 30-40 (median: 34.5), body weight 76-125 (median: 94.9) kg, age 20-40 (median: 35.5) years, isocaloric nutrition), 20 in the wIRA group and 20 in the control group. In both groups each participant performed 3 times per week over 4 weeks for 45 minutes bicycle ergometer endurance exercise with a constant load according to a lactate level of 2 mmol/l (aerobic endurance load, as determined before the intervention period). In the wIRA group in addition large parts of the body (including waist, hip, and thighs) were irradiated during all ergometries of the intervention period with visible light and a predominant part of water-filtered infrared-A (wIRA), using the irradiation unit “Hydrosun® 6000” with 10 wIRA radiators (Hydrosun® Medizintechnik, Müllheim, Germany, radiator type 500, 4 mm water cuvette, yellow filter, water-filtered spectrum 500-1400 nm) around a speed independent bicycle ergometer. Main variable of interest: change of “the sum of circumferences of waist, hip, and both thighs of each patient” over the intervention period (4 weeks). Additional variables of interest: body weight, body mass index BMI, body fat percentage, fat mass, fat-free mass, water mass (analysis of body composition by tetrapolar bioimpedance analysis), assessment of an arteriosclerotic risk profile by blood investigation of variables of lipid metabolism (cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL, apolipoprotein A1, apolipoprotein B), clinical chemistry (fasting glucose, alanin-aminotransferase ALT (= glutamyl pyruvic transaminase GPT), gamma-glutamyl-transferase GGT, creatinine, albumin), endocrinology (leptin, adiponectin (= adipo Q), homocysteine, insulin). All variables were at least measured before and after the intervention period. Ergometry (ECG, blood pressure behaviour, lactate curve with power at 2, 3 and 4 mmol/l) before the intervention period. In addition: nutrition training ahead of and during the intervention period with a nutrition protocol over one week for assessment of the daily energy intake; calculation of basic metabolic rate and total energy requirement. Assessment of undesired effects. Only methods of non-parametric statistics were used, both descriptive (median, percentiles of 25 and 75 (= interquartile range), minimum, maximum) and confirmatory (two-sided Mann-Whitney U test for unpaired samples for the only one main variable of interest). Total error probability: .05 (5%). An intention to treat analysis ITT with last observed carry forward method was used preferably (presented results) and in addition an on treatment analysis OT. Only 2 (treatment group) and 4 (control group) drop-outs occurred (mostly due to lack of time). Results: The “sum of circumferences of waist, hip, and both thighs of each patient” decreased during the 4 weeks significantly more (p<.001) in the wIRA group than in the control group: medians and interquartile ranges: -8.0 cm (-10.5 cm/-4.1 cm) vs. -1.8 cm (-4.4 cm/0.0 cm). As well “body weight of each patient” decreased during the 4 weeks markedly more in the wIRA group than in the control group: medians and interquartile ranges: -1.9 kg (-4.0 kg/0.0 kg) vs. 0.0 kg (-1.5 kg/+0.4 kg); median of body weight changed from 99.3 kg to 95.6 kg (wIRA) vs. 89.9 kg to 89.6 kg (control). A similar effect showed the body mass index BMI. Blood variables of interest remained unchanged or showed some slight improvements during the treatment period, concerning most variables with no obvious differences between the two groups; insulin showed a slight trend to decrease in the wIRA group and to increase in the control group. Undesired effects of the treatment were not seen. Discussion: The results of the study suggest, that wIRA – during moderate bicycle ergometer endurance exercise as lipolytic stimulus – increases local lipolysis with a local fat reduction (thighs) in the otherwise bradytrophic fatty tissue. The presumably underlying mechanisms of wIRA have already been proven: wIRA acts both by thermal effects and by non-thermal effects. Thermal effects of wIRA are the generation of a therapeutic field of warmth with the increase of tissue temperature, tissue oxygen partial pressure, and tissue blood flow, and by this regional metabolism. As fatty tissue normally has a slow metabolism (bradytrophic and hypothermic tissue) with a low rate of lipolysis, wIRA can increase lipolysis in fatty tissue and the mobilized fats are burned in musculature during the ergometer exercise. Conclusion: The results of the study indicate, that wIRA irradiation during moderate ergometer endurance exercise can be used – in combination with an appropriate nutrition – to improve body composition, especially local fat distribution, and the reduction of fat and body weight in obese persons. PMID:19675696
Microtubule Flux and Sliding in Mitotic Spindles of Drosophila EmbryosV⃞
Brust-Mascher, Ingrid; Scholey, Jonathan M.
2002-01-01
We proposed that spindle morphogenesis in Drosophila embryos involves progression through four transient isometric structures in which a constant spacing of the spindle poles is maintained by a balance of forces generated by multiple microtubule (MT) motors and that tipping this balance drives pole-pole separation. Here we used fluorescent speckle microscopy to evaluate the influence of MT dynamics on the isometric state that persists through metaphase and anaphase A and on pole-pole separation in anaphase B. During metaphase and anaphase A, fluorescent punctae on kinetochore and interpolar MTs flux toward the poles at 0.03 μm/s, too slow to drive chromatid-to-pole motion at 0.11 μm/s, and during anaphase B, fluorescent punctae on interpolar MTs move away from the spindle equator at the same rate as the poles, consistent with MT-MT sliding. Loss of Ncd, a candidate flux motor or brake, did not affect flux in the metaphase/anaphase A isometric state or MT sliding in anaphase B but decreased the duration of the isometric state. Our results suggest that, throughout this isometric state, an outward force exerted on the spindle poles by MT sliding motors is balanced by flux, and that suppression of flux could tip the balance of forces at the onset of anaphase B, allowing MT sliding and polymerization to push the poles apart. PMID:12429839
30 CFR 56.12048 - Communication conductors on power poles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Communication conductors on power poles. 56... Electricity § 56.12048 Communication conductors on power poles. Telegraph, telephone, or signal wires shall not be installed on the same crossarm with power conductors. When carried on poles supporting...
30 CFR 56.12048 - Communication conductors on power poles.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Communication conductors on power poles. 56... Electricity § 56.12048 Communication conductors on power poles. Telegraph, telephone, or signal wires shall not be installed on the same crossarm with power conductors. When carried on poles supporting...
Economics of Red Pine Management for Utility Pole Timber
Gerald H. Grossman; Karen Potter-Witter
1991-01-01
Including utility poles in red pine management regimes leads to distinctly different management recommendations. Where utility pole markets exist, managing for poles will maximize net returns. To do so, plantations should be maintained above 110 ft2/ac, higher than usually recommended. In Michigan's northern lower peninsula, approximately...
Fiber grating system used to measure strain in a 22-ft composite utility pole
NASA Astrophysics Data System (ADS)
Udd, Eric; Corona, Kelli; Slattery, Kerry T.; Dorr, Donald J.
1996-05-01
Composite utility poles have significant advantages with respect to wooden utility poles that include superior strength and uniformity, light weight for ease of deployment, the ability to be recycled reducing hazardous waste associated with chemically treated wooden poles, and compatibility with embedded fiber optic sensors allowing structural loads to be monitored. This paper reports tests conducted of fiber optic grating sensors in combination with an overcoupled coupler demodulation system to support structural testing of a 22 foot composite pole.
Tension and compression measurements in composite utility poles using fiber optic grating sensors
NASA Astrophysics Data System (ADS)
Udd, Eric; Corona-Bittick, Kelli; Slattery, Kerry T.; Dorr, Donald J.
1995-04-01
Composite utility poles have the potential to overcome many of the limitations of wooden poles that are currently widely used. Significant advantages include superior strength and uniformity, light weight for ease of deployment, the ability to be recycled reducing hazardous waste associated with chemically treated wooden poles, and compatibility with embedded fiber optic sensors allowing structural loads to be monitored. This paper describes the usage of fiber optic grating sensors to support structural testing of a 22 foot composite pole.
CDR De Winne takes Water Samples for analysis in the US Lab
2009-10-20
ISS021-E-010368 (20 Oct. 2009) --- European Space Agency astronaut Frank De Winne (foreground), Expedition 21 commander, fills a bag with water in the Destiny laboratory of the International Space Station. NASA astronaut Jeffrey Williams, flight engineer, exercises on the Cycle Ergometer with Vibration Isolation System (CEVIS) at left.
Coleman performs VO2 Max PFS Software Calibrations and Instrument Check
2011-02-24
ISS026-E-029180 (24 Feb. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, performs VO2max portable Pulmonary Function System (PFS) software calibrations and instrument check while using the Cycle Ergometer with Vibration Isolation System (CEVIS) in the Destiny laboratory of the International Space Station.
Underwater Cycle Ergometry: Power Requirements With and Without Diver Thermal Dress
2009-01-01
waterproofed Collins Pedal Mate ergometers that are no longer available. A pedal shaft drives the shaft of a hysteresis brake (HB210, Magtrol; Buffalo, NY...NEDU, regular bicycle pedals with toe straps/ over canvas shoes were used in Buffalo (personal 13 communication). The foot cups used at NEDU are
Effects of an Aerobic Rowing Training Regimen in Young Adults with Down Syndrome.
ERIC Educational Resources Information Center
Varela, Ana Maria; Sardinha, Luis Bettencount; Pitetti, Kenneth H.
2001-01-01
Eight young adult males with Down syndrome received a 16-week rowing ergometry training regimen. Following training, no changes in cardiovascular fitness were found but participants did achieve significantly higher levels of work performance on both treadmill and rowing ergometer tests than did a control group. (Contains references.) (Author/DB)
Exhaled methane concentration profiles during exercise on an ergometer
Szabó, A; Ruzsanyi, V; Unterkofler, K; Mohácsi, Á; Tuboly, E; Boros, M; Szabó, G; Hinterhuber, H; Amann, A
2016-01-01
Exhaled methane concentration measurements are extensively used in medical investigation of certain gastrointestinal conditions. However, the dynamics of endogenous methane release is largely unknown. Breath methane profiles during ergometer tests were measured by means of a photoacoustic spectroscopy based sensor. Five methane-producing volunteers (with exhaled methane level being at least 1 ppm higher than room air) were measured. The experimental protocol consisted of 5 min rest—15 min pedalling (at a workload of 75 W)—5 min rest. In addition, hemodynamic and respiratory parameters were determined and compared to the estimated alveolar methane concentration. The alveolar breath methane level decreased considerably, by a factor of 3–4 within 1.5 min, while the estimated ventilation-perfusion ratio increased by a factor of 2–3. Mean pre-exercise and exercise methane concentrations were 11.4 ppm (SD:7.3) and 2.8 ppm (SD:1.9), respectively. The changes can be described by the high sensitivity of exhaled methane to ventilationperfusion ratio and are in line with the Farhi equation. PMID:25749807
Haemoglobin saturation during incremental arm and leg exercise.
Powers, S. K.; Dodd, S.; Woodyard, J.; Beadle, R. E.; Church, G.
1984-01-01
There are few reports concerning the alterations in the percent of haemoglobin saturated with oxygen (%SO2) during non-steady state incremental exercise. Further, no data exist to describe the %SO2 changes during arm exercise. Therefore, the purpose of this study was made to assess the dynamic changes in %SO2 during incremental arm and leg work. Nine trained subjects (7 males and 2 females) performed incremental arm and leg exercise to exhaustion on an arm crank ergometer and a cycle ergometer, respectively. Ventilation and gas exchange measurements were obtained minute by minute via open circuit spirometry and changes in %SO2 were recorded via an ear oximeter. No significant difference (p greater than 0.05) existed between arm and leg work in end-tidal oxygen (PETO2), end-tidal carbon dioxide (PETCO2), or %SO2 when compared as a function of percent VO2 max. These results provide evidence that arterial O2 desaturation occurs in a similar fashion in both incremental arm and leg work with the greatest changes in %SO2 occurring at work rates greater than 70% VO2 max. PMID:6435715
NASA Technical Reports Server (NTRS)
Greenisen, Michael C.; Fortney, Suzanne M.; Lee, Stuart M. C.; Moore, Alan D.; Barrows, Linda H.
1993-01-01
Several investigations within the Exercise Countermeasures Project at the NASA Johnson Space Center focused on the assessment of maximum oxygen consumption (VO2(sub max)) within the Astronaut Corps pre- and postspace flight. Investigations during the Apollo era suggested that there was a significant decrease in postflight VO2(sub max) when compared to preflight values, and current studies have documented that this trend continues in the Space Shuttle era. It is generally accepted and was confirmed in our laboratory that VO2(sub max) can be predicted from submaximal measures taken during graded exercise tests on the cycle ergometer with respect to populations. However, previous work had not examined the effect of day-to-day variations in the physiologic responses that might alter these predictions for individuals. Stability of individual submaximal data over serial tests is important so that predicted changes in VO2(sub max) are reflective of actual VO2(sub max) changes. Therefore, the purpose of this investigation was to determine which of the accepted equations to predict VO2(sub max) would be less affected by normal daily physiologic changes.
Martín Rodríguez, Francisco; Fernández Pérez, Cristina; Castro Villamor, Miguel; Martín Conty, José Luis; Arnillas Gómez, Pedro; Casado Vicente, Verónica
2018-01-01
Our aim was to determine the usefulness of level D personal protective equipment (PPE) in safeguarding health care staff who perform cardiopulmonary resuscitation (CPR). Quasi-experimental, uncontrolled trial in 96 volunteers chosen randomly and stratified by sex, level of training, and professional category. The subjects were selected from a convenience sample of 164 nurses, physicians, and students of nursing and medicine (40 men [41.66%] and 56 women [58.33%]). The mean (SD) age was 31 (11) years. The Conconi test was used to determine heart rate (HR) at the anaerobic threshold on a cycle ergometer. That HR was then compared to each volunteer's maximum HR during performance of CPR while wearing PPE. While the volunteers were performing CPR, 46.9% of them surpassed their maximum recommendable HR recorded during the cycle ergometer test. We found that performing CPR while wearing level D PPE requires intense physical effort. Special situations should be taken into consideration when developing protocols for situations that require staff to wear PPE. Staff who must perform CPR under these conditions should be given specific training.
Permanent-magnet multipole with adjustable strength
Halbach, K.
1982-09-20
Two or more magnetically soft pole pieces are symmetrically positioned along a longitudinal axis to provide a magnetic field within a space defined by the pole pieces. Two or more permanent magnets are mounted to an external magnetically-soft cylindrical sleeve which rotates to bring the permanent magnets into closer coupling with the pole pieces and thereby adjustably control the field strength of the magnetic field produced in the space defined by the pole pieces. The permanent magnets are preferably formed of rare earth cobalt (REC) material which has a high remanent magnetic field and a strong coercive force. The pole pieces and the permanent magnets have corresponding cylindrical surfaces which are positionable with respect to each other to vary the coupling there between. Auxiliary permanent magnets are provided between the pole pieces to provide additional magnetic flux to the magnetic field without saturating the pole pieces.
Permanent magnet multipole with adjustable strength
Halbach, Klaus
1985-01-01
Two or more magnetically soft pole pieces are symmetrically positioned along a longitudinal axis to provide a magnetic field within a space defined by the pole pieces. Two or more permanent magnets are mounted to an external magnetically-soft cylindrical sleeve which rotates to bring the permanent magnets into closer coupling with the pole pieces and thereby adjustably control the field strength of the magnetic field produced in the space defined by the pole pieces. The permanent magnets are preferably formed of rare earth cobalt (REC) material which has a high remanent magnetic field and a strong coercive force. The pole pieces and the permanent magnets have corresponding cylindrical surfaces which are positionable with respect to each other to vary the coupling therebetween. Auxiliary permanent magnets are provided between the pole pieces to provide additional magnetic flux to the magnetic field without saturating the pole pieces.
A vision fusion treatment system based on ATtiny26L
NASA Astrophysics Data System (ADS)
Zhang, Xiaoqing; Zhang, Chunxi; Wang, Jiqiang
2006-11-01
Vision fusion treatment is an important and effective project to strabismus children. The vision fusion treatment system based on the principle for eyeballs to follow the moving visual survey pole is put forward first. In this system the original position of visual survey pole is about 35 centimeters far from patient's face before its moving to the middle position between the two eyeballs. The eyeballs of patient will follow the movement of the visual survey pole. When they can't follow, one or two eyeballs will turn to other position other than the visual survey pole. This displacement is recorded every time. A popular single chip microcomputer ATtiny26L is used in this system, which has a PWM output signal to control visual survey pole to move with continuously variable speed. The movement of visual survey pole accords to the modulating law of eyeballs to follow visual survey pole.
Pole-Like Street Furniture Decompostion in Mobile Laser Scanning Data
NASA Astrophysics Data System (ADS)
Li, F.; Oude Elberink, S.; Vosselman, G.
2016-06-01
Automatic semantic interpretation of street furniture has become a popular topic in recent years. Current studies detect street furniture as connected components of points above the street level. Street furniture classification based on properties of such components suffers from large intra class variability of shapes and cannot deal with mixed classes like traffic signs attached to light poles. In this paper, we focus on the decomposition of point clouds of pole-like street furniture. A novel street furniture decomposition method is proposed, which consists of three steps: (i) acquirement of prior-knowledge, (ii) pole extraction, (iii) components separation. For the pole extraction, a novel global pole extraction approach is proposed to handle 3 different cases of street furniture. In the evaluation of results, which involves the decomposition of 27 different instances of street furniture, we demonstrate that our method decomposes mixed classes street furniture into poles and different components with respect to different functionalities.
Pole of rotating analysis of present-day Juan de Fuca plate motion
NASA Technical Reports Server (NTRS)
Nishimura, C.; Wilson, D. S.; Hey, R. N.
1984-01-01
Convergence rates between the Juan de Fuca and North American plates are calculated by means of their relative, present-day pole of rotation. A method of calculating the propagation of errors in addition to the instantaneous poles of rotation is also formulated and applied to determine the Euler pole for Pacific-Juan de Fuca. This pole is vectorially added to previously published poles for North America-Pacific and 'hot spot'-Pacific to obtain North America-Juan de Fuca and 'hot spot'-Juan de Fuca, respectively. The errors associated with these resultant poles are determined by propagating the errors of the two summed angular velocity vectors. Under the assumption that hot spots are fixed with respect to a mantle reference frame, the average absolute velocity of the Juan de Puca plate is computed at approximately 15 mm/yr, thereby making it the slowest-moving of the oceanic plates.
Stöggl, Thomas; Welde, Boye; Supej, Matej; Zoppirolli, Chiara; Rolland, Carsten G.; Holmberg, Hans-Christer; Pellegrini, Barbara
2018-01-01
Here, female and male elite cross-country (XC) skiers were compared on varying terrain during an official 10-km (women) and 15-km (men) Norwegian championship race. On the basis of race performance, 82 skiers were classified as fast (FS) (20 women, 20 men) or slower (SS) (21, 21) skiers. All were video recorded on flat (0°), intermediate (3.5°), uphill (7.1°) and steep uphill (11°) terrain during the race at a distance of 0.8, 1.2, 2.1 and 7.1 km from the start, respectively. All skiers employed exclusively double-poling (DP) on the flat section and, except for the male winner, exclusively diagonal stride (DIA) on the uphill sections. On the intermediate section, more men than women utilized DP and fewer DIA (p = 0.001), with no difference in kick double-poling (DPK). More FS than SS utilized DPK and fewer DIA (p = 0.001), with similar usage of DP. Males skied with faster and longer cycles but lower cycle rate compared with females (p < 0.001), with largest absolute sex differences on flat terrain (p < 0.001) and largest relative differences for cycle velocity and length on intermediate and uphill terrain. External power output rose with increasing incline, being higher for men and FS (p < 0.001). Cycle velocity on flat terrain was the best predictor of mean race velocity for the men, while cycle velocity on steep uphill was the best predictor for the women (both p < 0.001). In conclusion, incline, sex and level of performance influenced cycle characteristics and power output. Greatest absolute sex gap was on flat terrain, whereas the relative difference was greatest on intermediate and steep uphill terrain. We recommend usage of more DP and/or DPK, and less DIA and fewer transitions between techniques on intermediate terrain. Predictors of race performance are sex specific with greatest potential for enhancing performance on flat terrain for men and on steep uphill terrain for women. Key points There was a main effect of sex and level of performance, with longer and more rapid cycles by male than female skiers and by faster than slower skiers. The largest absolute sex differences in cycle velocity and length were observed on flat terrain, with these differences narrowing as the incline rose. However, the greatest relative sex differences were in cycle velocity on the intermediate terrain (23.3%) and for cycle length on steep uphill terrain (27.0%). The men employed DP and DPK to a greater extent and with fewer transitions on intermediate terrain than the women. Faster skiers (especially women) employed DPK to a greater and DIA to a lesser extent than the slower skiers, with approximately equal usage of DP. Cycle velocity on flat terrain was the best predictor of mean race velocity for the men, while cycle velocity on steep uphill terrain was the best predictor in the case of the women. As the incline increased, cycle velocity, cycle length and pole swing time were reduced, while poling time and external power output rose. A J-shaped pattern with respect to cycle rate was observed, with the lowest values on intermediate and highest on steep uphill terrain. PMID:29535586
Tatchyn, Roman O.; Csonka, Paul L.; Cremer, Jay T.
1990-12-11
Micropole undulators for use in the generation of x-rays from moving charged particles are disclosed. Two rows of spaced apart poles are arranged so that each pole produces a magnetic field aligned with all other similar fields. The poles are the ends of "C"-shaped magnets. In each row, adjacent poles are separated by spacers made of a superconducting material.
Theoretical modeling and experimental analyses of laminated wood composite poles
Cheng Piao; Todd F. Shupe; Vijaya Gopu; Chung Y. Hse
2005-01-01
Wood laminated composite poles consist of trapezoid-shaped wood strips bonded with synthetic resin. The thick-walled hollow poles had adequate strength and stiffness properties and were a promising substitute for solid wood poles. It was necessary to develop theoretical models to facilitate the manufacture and future installation and maintenance of this novel...
Evidence for Phyllosilicates near the Lunar South Pole
NASA Technical Reports Server (NTRS)
Vilas, Faith; Jensen, E.; Domingue, Deborah; McFadden, L.; Coombs, Cassandraa; Mendell, Wendell
1998-01-01
While theoretically water ice could be stable in permanently shadowed areas near the lunar poles, there is conflicting observational evidence for the existence of water ice at either pole. Clementine's bistatic radar resumed a weak signal commensurate with water ice in the South Pole Aitken Basin; however, groundbased radar searches have not detected such a signal at either pole. Lunar Prospector measured large amounts of H (attributed to water) at both poles; however, Galileo near-infrared spectral measurements of the north polar region did not detect the prominent 3.0 micron absorption feature due to interlayer and adsorbed water in phyllosilicates. Evidence for the existence of water at the lunar poles is still ambiguous and controversial. We present evidence, based on the analysis of Galileo SSI images, for the presence of phyllosilicates near the lunar south pole. Using the color image sequence (560 nm, 670 nm, 756 nm, and 889 nm) of Lunmap 14 taken during the Galileo Earth-Moon pass I, we have identified areas that show evidence for a 0.7 microns absorption feature present in Fe-bearing phyllosilicates.
Electrical Transfer Function and Poling Mechanisms for Nonlinear Optical Polymer Modulators
NASA Technical Reports Server (NTRS)
Watson, Michael Dale
2004-01-01
Electro-Optic Polymers hold great promise in increased electro-optic coefficients as compared to their inorganic corollaries. Many researchers have focused on quantum chemistry to describe how the dipoles respond to temperature and electric fields. Much work has also been done for single layer films to confirm these results. For optical applications, waveguide structures are utilized to guide the optical waves in 3 layer stacks. Electrode poling is the only practical poling method for these structures. This research takes an electrical engineering approach to develop poling models and electrical and optical transfer functions of the waveguide structure. The key aspect of the poling model is the large boundary charge density deposited during the poling process. The boundary charge density also has a large effect on the electrical transfer function which is used to explain the transient response of the system. These models are experimentally verified. Exploratory experiment design is used to study poling parameters including time, temperature, and voltage. These studies verify the poling conditions for CLDX/APC and CLDZ/APEC guest host electro optic polymer films in waveguide stacks predicted by the theoretical developments.
NASA Astrophysics Data System (ADS)
Sato, Tomoyuki; Uemura, Satoshi; Asakawa, Akira; Yokoyama, Shigeru; Honda, Hideki; Horikoshi, Kazuhiro
In this study, we experimentally examined the possibility of the internal short circuit of an air switch due to the sparkover between different poles under the condition that no surge arrester exists in neighboring poles and one of three surge arresters is omitted at the pole with an air switch. Experiments at Shiobara Testing Yard and Akagi Testing Center of CRIEPI clarified the following. Fault current may flow via the grounding point of a pole with an air switch and that of the next pole on a different phase from grounded phase of the pole with an air switch. If the low-voltage wire, overhead ground wire or communication wire forms a short circuit between them, ultimately the air switch may burn out. Moreover Fault current continues even if the length of the short-circuit between different poles is increased. Although the increase of the short-circuit length results in the increase of wire impedance, the amount of increase is still small compared with source impedance.
Macro Fiber Piezocomposite Actuator Poling Study
NASA Technical Reports Server (NTRS)
Werlink, Rudy J.; Bryant, Robert G.; Manos, Dennis
2002-01-01
The performance and advantages of Piezocomposite Actuators are to provide a low cost, in-situ actuator/sensor that is flexible, low profile and high strain per volt performance in the same plane of poled voltage. This paper extends reported data for the performance of these Macrofiber Composite (MFC) Actuators to include 4 progressively narrower Intedigitized electrode configurations with several line widths and spacing ratios. Data is reported for max free strain, average strain per applied volt, poling (alignment of the electric dipoles of the PZT ceramic) voltage vs. strain and capacitance, time to poling voltage 95% saturation. The output strain per volt progressively increases as electrode spacing decreases, with saturation occurring at lower poling voltages. The narrowest spacing ratio becomes prone to voltage breakdown or short circuits limiting the spacing width with current fabrication methods. The capacitance generally increases with increasing poling voltage level but has high sensitivity to factors such as temperature, moisture and time from poling which limit its usefulness as a simple indicator. The total time of applied poling voltage to saturate or fully line up the dipoles in the piezoceramic was generally on the order of 5-20 seconds. Less sensitivity to poling due to the applied rate of voltage increase over a 25 to 500 volt/second rate range was observed.
Bludau, Sebastian; Bzdok, Danilo; Gruber, Oliver; Kohn, Nils; Riedl, Valentin; Sorg, Christian; Palomero-Gallagher, Nicola; Müller, Veronika I.; Hoffstaedter, Felix; Amunts, Katrin; Eickhoff, Simon B.
2017-01-01
Objective The heterogeneous human frontal pole has been identified as a node in the dysfunctional network of major depressive disorder. The contribution of the medial (socio-affective) versus lateral (cognitive) frontal pole to major depression pathogenesis is currently unclear. The present study performs morphometric comparison of the microstructurally informed subdivisions of human frontal pole between depressed patients and controls using both uni- and multivariate statistics. Methods Multi-site voxel- and region-based morphometric MRI analysis of 73 depressed patients and 73 matched controls without psychiatric history. Frontal pole volume was first compared between depressed patients and controls by subdivision-wise classical morphometric analysis. In a second approach, frontal pole volume was compared by subdivision-naive multivariate searchlight analysis based on support vector machines. Results Subdivision-wise morphometric analysis found a significantly smaller medial frontal pole in depressed patients with a negative correlation of disease severity and duration. Histologically uninformed multivariate voxel-wise statistics provided converging evidence for structural aberrations specific to the microstructurally defined medial area of the frontal pole in depressed patients. Conclusions Across disparate methods, we demonstrated subregion specificity in the left medial frontal pole volume in depressed patients. Indeed, the frontal pole was shown to structurally and functionally connect to other key regions in major depression pathology like the anterior cingulate cortex and the amygdala via the uncinate fasciculus. Present and previous findings consolidate the left medial portion of the frontal pole as particularly altered in major depression. PMID:26621569
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, B.B.; Ripp, J.; Sims, R.C.
The Electric Power Research Institute (EPRI) is studying the environmental impact of preservatives associated with in-service utility poles. As part of this endeavor, two EPRI contractors, META Environmental, Inc. (META) and Atlantic Environmental Services, Inc. (Atlantic), have collected soil samples from around wood utility poles nationwide, for various chemical and physical analyses. This report covers the results for 107 pole sites in the US. These pole sites included a range of preservative types, soil types, wood types, pole sizes, and in-service ages. The poles in this study were preserved with one of two types of preservative: pentachlorophenol (PCP) or creosote.more » Approximately 40 to 50 soil samples were collected from each wood pole site in this study. The soil samples collected from the pole sites were analyzed for chlorinated phenols and total petroleum hydrocarbons (TPH) if the pole was preserved with PCP, or for polycyclic aromatic hydrocarbons (PAHs) if the pole was preserved with creosote. The soil samples were also analyzed for physical/chemical parameters, such as pH, total organic carbon (TOC), and cationic exchange capacity (CEC). Additional samples were used in studies to determine biological degradation rates, and soil-water distribution and retardation coefficients of PCP in site soils. Methods of analysis followed standard EPA and ASTM methods, with some modifications in the chemical analyses to enable the efficient processing of many samples with sufficiently low detection limits for this study. All chemical, physical, and site-specific data were stored in a relational computer database.« less
Helicopter-based live-line work. Volume 1, Helicopter platform work between phases: Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gela, G.
1993-06-01
This report presents experimental data on tests of a configuration consisting of a helicopter between two energized phases (for AC and switching surge) or poles (for DC). The configuration is that related to live-line work from a hovering helicopter. The McDonnell Douglas 500 Series helicopter was used for the tests. All tests were performed with phase-to-phase, or pole-to-pole energization. For AC tests, proper relationship between the phase-to-ground voltages and the phase-to-phase voltage was maintained by energizing the experimental setup from a balanced 3-{phi} AC source. For DC tests, one pole was energized with positive DC voltage to ground, while themore » other pole was energized with negative DC voltage to ground. For switching surge tests, a surge of positive polarity and a specific peak voltage magnitude was applied to one phase while a surge of negative polarity and the same peak voltage Magnitude was simultaneously applied to the other phase, resulting in {alpha} = 0.5 ({alpha} is the ratio between negative and total surge). In the research program, four conditions were investigated, namely helicopter operating versus not operating, and helicopter bonded to one phase or pole versus not bonded. Results from this research show effects of the rotating main rotor blade of the helicopter, effect of the position of the electrically floating helicopter in the phase-to-phase or pole-to-pole gap, effects of the mannequin, importance of the polarity of the DC poles and switching surges, and effects of inclement weather such as rain. The overall conclusion of this research is that the phase-to-phase or pole-to-pole spacings that cause sparkover with the helicopter between phases (poles) were always significantly smaller than the typical spacings on actual existing overhead transmission lines of the corresponding voltage rating.« less
Materny, Jacek; Chojnacka, Hanna; Urasińska, Elzbieta; Gawrych, Elzbieta
2011-01-01
The aim of this study was to assess structural changes of the upper pole in renal duplication with coexisting ureterocele with regard to primary and/or secondary lesions. These changes might be of importance in treatment planning. The material of this study consisted of clinical documentation and results of histopathology of 23 upper poles removed due to renal duplication with coexisting ureterocele. The qualification criterion was preserved function of the upper pole seen with 99mTc-DTPA (99mTechnetium diethylenetriaminepentaacetic acid)/99mTc-DMSA (99mTechnetium dimercaptosuccinic acid). Resection of the upper pole was indicated in patients with recurrent urinary tract infections and/or persistent vesicoureteral reflux to the lower pole following endoscopic surgery of the ureterocele and/or low function of the upper pole. Morphological lesions were classified as primary (dysplasia) or secondary lesions. The patients were operated at the Department of Pediatric and Oncologic Surgery, PMU, in 1990-2008. The study group consisted of 17 girls and 6 boys aged from 4 months to 9 years (mean 40 months). Recurrent urinary tract infections noted in 16 (70%) children were the most frequent indication for surgery. The preoperative mean function of the renal poles assessed with DTPA/DMSA represented 6% of the differential renal function. Dysplasia was identified in eight resected renal poles (34%) with coexisting secondary lesions in three of them. Secondary lesions only were seen in 15 poles (66%). There was no correlation between age and incidence of dysplasia during follow-up (Pearson's correlation coefficient r = 0.031). Secondary lesions are a quite frequent finding in resected upper poles. As 66% of the renal poles studied with histopathology revealed secondary lesions only, we believe that renal sparing treatment is justified in cases of urinary duplication with coexisting ureterocele.
Acute effects of walking with Nordic poles in persons with mild to moderate low-back pain.
Revord, Landon P; Lomond, Karen V; Loubert, Peter V; Hammer, Roger L
2016-01-01
Regular walking with or without Nordic poles is effective over time at reducing discomfort in individuals with chronic low back pain (LBP). Nordic pole use increases balance and stability, distributes weight through the arms and torso, and decreases loading of the spine and lower limbs. The purpose of this study was to determine if Nordic poles would reduce perceived acute discomfort while self-paced walking in individuals with LBP. We also examined whether walking with or without poles increased heart rate (HR) and ratings of perceived exertion (RPE) or speed of movement. Subjects included 20 adults (12 males, 8 females; mean age of 45.1±16.3) who were experiencing LBP of at least six months' duration (Oswestry Disability Index (ODI): mean 17 ± 8%, range 6-36% indicating minimal to moderate disability) with no current active flare-up. Participants walked a predetermined dirt-path course (805 m or 0.5 mi) with and without poles in randomized order. Data were analyzed using a 2 X 2 repeated measures ANOVA (Condition X Time), where Condition was poles vs no poles and Time was pre- and post-walk. HR and RPE increased significantly from walking the course, whereas pain did not change. There were also no differences between walking with or without poles for pain (ODI Sec #1: 0.2 points, p=0.324), HR (4 bpm, p=0.522) and RPE (0 points, p=0.759). The mean course time (sec) was slower with poles: 617±87 vs 566±65 (p<0.001). Unexpectedly, there was a noticeable drop in pain following the warm up which was done using poles (0.9 points, p<0.001). Nordic pole use is well tolerated in those with current back pain and can be encouraged, however it cannot be recommended as a superior method of addressing acute symptoms when walking.
Giant kidney worm (Dioctophyma renale) infection mimicking retroperitoneal neoplasm.
Sun, T; Turnbull, A; Lieberman, P H; Sternberg, S S
1986-07-01
A 50-year-old Chinese man was found by ultrasound and computed tomography to have a retroperitoneal mass in the right upper quadrant of the abdomen. At operation, a hemorrhagic cyst was detected at the upper pole of the right kidney adjacent to the adrenal gland. Microscopic examination revealed that the cyst wall was composed of granulomatous tissue loaded with eggs and cross-sections of parasites, identified as Dioctophyma renale. The eggs were characterized by a birefringent striated double wall. The presence of cross sections of adult worms of D. renale in human tissue has not been previously described. Another unique feature of this case was that the right kidney was intact, as examined grossly at laparotomy and by intravenous pyelography. Eggs were not detected in the urine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz
This paper presents the design considerations in cogging torque minimization in two types of transverse flux machines. The machines have a double stator-single rotor configuration with flux concentrating ferrite magnets. One of the machines has pole windings across each leg of an E-Core stator. Another machine has quasi-U-shaped stator cores and a ring winding. The flux in the stator back iron is transverse in both machines. Different methods of cogging torque minimization are investigated. Key methods of cogging torque minimization are identified and used as design variables for optimization using a design of experiments (DOE) based on the Taguchi method.more » A three-level DOE is performed to reach an optimum solution with minimum simulations. Finite element analysis is used to study the different effects. Two prototypes are being fabricated for experimental verification.« less
Frequent POLE1 p.S297F mutation in Chinese patients with ovarian endometrioid carcinoma.
Zou, Yang; Liu, Fa-Ying; Liu, Huai; Wang, Feng; Li, Wei; Huang, Mei-Zhen; Huang, Yan; Yuan, Xiao-Qun; Xu, Xiao-Yun; Huang, Ou-Ping; He, Ming
2014-03-01
The catalytic subunit of DNA polymerase epsilon (POLE1) functions primarily in nuclear DNA replication and repair. Recently, POLE1 mutations were detected frequently in colorectal and endometrial carcinomas while with lower frequency in several other types of cancer, and the p.P286R and p.V411L mutations were the potential mutation hotspots in human cancers. Nevertheless, the mutation frequency of POLE1 in ovarian cancer still remains largely unknown. Here, we screened a total of 251 Chinese samples with distinct subtypes of ovarian carcinoma for the presence of POLE1 hotspot mutations by direct sequencing. A heterozygous somatic POLE1 mutation, p.S297F (c.890C>T), but not p.P286R and p.V411L hotspot mutations observed in other cancer types, was identified in 3 out of 37 (8.1%) patients with ovarian endometrioid carcinoma; this mutation was evolutionarily highly conserved from Homo sapiens to Schizosaccharomyces. Of note, the POLE1 mutation coexisted with mutation in the ovarian cancer-associated PPP2R1A (protein phosphatase 2, regulatory subunit A, α) gene in a 46-year-old patient, who was also diagnosed with ectopic endometriosis in the benign ovary. In addition, a 45-year-old POLE1-mutated ovarian endometrioid carcinoma patient was also diagnosed with uterine leiomyoma while the remaining 52-year-old POLE1-mutated patient showed no additional distinctive clinical manifestation. In contrast to high frequency of POLE1 mutations in ovarian endometrioid carcinoma, no POLE1 mutations were identified in patients with other subtypes of ovarian carcinoma. Our results showed for the first time that the POLE1 p.S297F mutation, but not p.P286R and p.V411L hotspot mutations observed in other cancer types, was frequent in Chinese ovarian endometrioid carcinoma, but absent in other subtypes of ovarian carcinoma. These results implicated that POLE1 p.S297F mutation might be actively involved in the pathogenesis of ovarian endometrioid carcinoma, but might not be actively involved in other subtypes of ovarian carcinoma. Copyright © 2014 Elsevier B.V. All rights reserved.
Casiraghi, Francesca; Chavez, Alberto O.; Davalli, Alberto M.; Naegelin, Terry; Comuzzie, Anthony G.; Frost, Patricia; Musi, Nicolas; Folli, Franco
2013-01-01
Introduction The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. Methods We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. Results In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. Conclusion SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with “gold standard”, IC, in humans. PMID:24069218
Acute consumption of a caffeinated energy drink enhances aspects of performance in sprint swimmers.
Lara, Beatriz; Ruiz-Vicente, Diana; Areces, Francisco; Abián-Vicén, Javier; Salinero, Juan José; Gonzalez-Millán, Cristina; Gallo-Salazar, César; Del Coso, Juan
2015-09-28
This study investigated the effect of a caffeinated energy drink on various aspects of performance in sprint swimmers. In a randomised and counterbalanced order, fourteen male sprint swimmers performed two acute experimental trials after the ingestion of a caffeinated energy drink (3 mg/kg) or after the ingestion of the same energy drink without caffeine (0 mg/kg; placebo). After 60 min of ingestion of the beverages, the swimmers performed a countermovement jump, a maximal handgrip test, a 50 m simulated competition and a 45 s swim at maximal intensity in a swim ergometer. A blood sample was withdrawn 1 min after the completion of the ergometer test. In comparison with the placebo drink, the intake of the caffeinated energy drink increased the height in the countermovement jump (49.4 (SD 5.3) v. 50.9 (SD 5.2) cm, respectively; P<0.05) and maximal force during the handgrip test with the right hand (481 (SD 49) v. 498 (SD 43) N; P<0.05). Furthermore, the caffeinated energy drink reduced the time needed to complete the 50 m simulated swimming competition (27.8 (SD 3.4) v. 27.5 (SD 3.2) s; P<0.05), and it increased peak power (273 (SD 55) v. 303 (SD 49) W; P <0.05) and blood lactate concentration (11.0 (SD 2.0) v. 11.7 (SD 2.1) mM; P<0.05) during the ergometer test. The caffeinated energy drink did not modify the prevalence of insomnia (7 v. 7%), muscle pain (36 v. 36%) or headache (0 v. 7%) during the hours following its ingestion (P>0.05). A caffeinated energy drink increased some aspects of swimming performance in competitive sprinters, whereas the side effects derived from the intake of this beverage were marginal at this dosage.
de Souza E Silva, Christina G; Kaminsky, Leonard A; Arena, Ross; Christle, Jeffrey W; Araújo, Claudio Gil S; Lima, Ricardo M; Ashley, Euan A; Myers, Jonathan
2018-05-01
Background Maximal oxygen uptake (VO 2 max) is a powerful predictor of health outcomes. Valid and portable reference values are integral to interpreting measured VO 2 max; however, available reference standards lack validation and are specific to exercise mode. This study was undertaken to develop and validate a single equation for normal standards for VO 2 max for the treadmill or cycle ergometer in men and women. Methods Healthy individuals ( N = 10,881; 67.8% men, 20-85 years) who performed a maximal cardiopulmonary exercise test on either a treadmill or a cycle ergometer were studied. Of these, 7617 and 3264 individuals were randomly selected for development and validation of the equation, respectively. A Brazilian sample (1619 individuals) constituted a second validation cohort. The prediction equation was determined using multiple regression analysis, and comparisons were made with the widely-used Wasserman and European equations. Results Age, sex, weight, height and exercise mode were significant predictors of VO 2 max. The regression equation was: VO 2 max (ml kg -1 min -1 ) = 45.2 - 0.35*Age - 10.9*Sex (male = 1; female = 2) - 0.15*Weight (pounds) + 0.68*Height (inches) - 0.46*Exercise Mode (treadmill = 1; bike = 2) ( R = 0.79, R 2 = 0.62, standard error of the estimate = 6.6 ml kg -1 min -1 ). Percentage predicted VO 2 max for the US and Brazilian validation cohorts were 102.8% and 95.8%, respectively. The new equation performed better than traditional equations, particularly among women and individuals ≥60 years old. Conclusion A combined equation was developed for normal standards for VO 2 max for different exercise modes derived from a US national registry. The equation provided a lower average error between measured and predicted VO 2 max than traditional equations even when applied to an independent cohort. Additional studies are needed to determine its portability.
Strength, power, and muscular endurance exercise and elite rowing ergometer performance.
Lawton, Trent W; Cronin, John B; McGuigan, Michael R
2013-07-01
Knowledge of the relationship between weight room exercises and various rowing performance measures is limited; this information would prove useful for sport-specific assessment of individual needs and exercise prescription. The purpose of this study was to establish strength, power, and muscular endurance exercises for weight room training, which are strong determinants of success in specific performance measures used to assess elite rowers. Nineteen heavyweight elite males determined their repetition maximum (RM) loads for exercises using a Concept 2 DYNO [5, 30, 60 and 120RM leg pressing and seated arm pulling (in Joules)] and free weights [1RM power clean (in kilograms) and 6RM bench pull (in kilograms and watts)]. Rowing performance measures included a 7-stage blood lactate response ergometer test (aerobic condition), time trials (500, 2000, and 5000 m), a peak stroke power test, and a 60-minute distance trial. Pearson correlation moments (r ≥ 0.7) and stepwise multiple linear regression calculations (R ≥ 50%) were used to establish strong common variances between weight room exercises and rowing ergometer performance (p ≤ 0.05). Weight room exercises were strong predictors of 2000-m, 500-m time (in seconds), and peak stroke power performance measures only. Bench pull power (in watts) and 1RM power clean (in kilograms) were the best 2-factor predictors of peak stroke power (R = 73%; standard error of the estimates [SEE] = 59.6 W) and 500 m (R = 70%; SEE = 1.75 seconds); while 5RM leg pressing (in Joules) and either 6RM bench pull (kg) or 60RM seated arm pulling (in Joules) the best predictors of 2000 m (R = 59%; SEE = 6.3 seconds and R = 57%; SEE = 6.4 seconds, respectively). Recommended exercises for weight room training include a 1RM power clean, 6RM bench pull, 5RM leg press, and 60RM seated arm pulling.
Tatchyn, R.O.; Csonka, P.L.; Cremer, J.T.
1990-12-11
Micropole undulators for use in the generation of x-rays from moving charged particles are disclosed. Two rows of spaced apart poles are arranged so that each pole produces a magnetic field aligned with all other similar fields. The poles are the ends of C''-shaped magnets. In each row, adjacent poles are separated by spacers made of a superconducting material. 11 figs.
49 CFR 234.243 - Wire on pole line and aerial cable.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Wire on pole line and aerial cable. 234.243... Maintenance, Inspection, and Testing Maintenance Standards § 234.243 Wire on pole line and aerial cable. Wire... bracket supported by a pole or other support. Wire shall not interfere with, or be interfered with by...
49 CFR 234.243 - Wire on pole line and aerial cable.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Wire on pole line and aerial cable. 234.243... Maintenance, Inspection, and Testing Maintenance Standards § 234.243 Wire on pole line and aerial cable. Wire... bracket supported by a pole or other support. Wire shall not interfere with, or be interfered with by...
Hirata, Kei; Ishida, Yoichi; Akashi, Tetsuya; Shindo, Daisuke; Tonomura, Akira
2012-01-01
The magnetic domain structure of the writer poles of perpendicular magnetic recording heads was studied using electron holography. Although the domain structure of a 100-nm-thick writer pole could be observed with a 300 kV transmission electron microscope, that of the 250-nm-thick writer pole could not be analyzed due to the limited transmission capability of the instrument. On the other hand, the detailed domain structure of the 250-nm-thick writer pole was successfully analyzed by a 1 MV electron microscope using its high transmission capability. The thickness and material dependency of the domain structure of a writer pole were discussed.
Albrecht, Jessica; Demmel, Maria; Schöpf, Veronika; Kleemann, Anna Maria; Kopietz, Rainer; May, Johanna; Schreder, Tatjana; Zernecke, Rebekka; Brückmann, Hartmut; Wiesmann, Martin
2011-01-01
The hypothesis of this experiment was that humans in an anxious state compared with a nonanxious state are able to increase anxiety levels in other humans via their body odors. Specifically, we hypothesized that male chemosensory anxiety signals compared with neutral chemosignals increase state anxiety of female subjects. Thirteen male subjects participated in 2 different sweat donation sessions: chemosignals were collected during participation in a high rope course (anxiety condition) and in an ergometer workout (neutral condition). State and trait anxiety were evaluated in 20 female odor recipients using Spielberger's state-trait anxiety inventory in a double-blind design. Comparison of state anxiety of odor donors between control and anxiety condition differed significantly indicating that our model of anxiety induction successfully led to the expected change in emotion. Comparison of state anxiety of odor recipients showed a trend toward higher state anxiety in the anxiety condition compared with the neutral condition after 5 min of odor exposure. After 20 min of odor exposure, state anxiety of female subjects was significantly higher during the perception of sweat collected during the anxiety condition in comparison with the perception of sweat collected during the neutral condition. This experiment gives evidence that male anxiety chemosignals compared with neutral chemosignals are capable of inducing an increased state anxiety in female subjects.
You Smell Dangerous: Communicating Fight Responses Through Human Chemosignals of Aggression.
Mutic, Smiljana; Parma, Valentina; Brünner, Yvonne F; Freiherr, Jessica
2016-01-01
The ability to detect conspecifics that represent a potential harm for an individual represents a high survival benefit. Humans communicate socially relevant information using all sensory modalities, including the chemosensory systems. In study 1, we investigated whether the body odor of a stranger with the intention to harm serves as a chemosignal of aggression. Sixteen healthy male participants donated their body odor while engaging in a boxing session characterized by aggression-induction methods (chemosignal of aggression) and while performing an ergometer session (exercise chemosignal). Self-reports on aggression-related physical activity, motivation to harm and angry emotions selectively increased after aggression induction. In study 2, we examined whether receivers smelling such chemosignals experience emotional contagion (e.g., anger) or emotional reciprocity (e.g., anxiety). The aggression and exercise chemosignals were therefore presented to 22 healthy normosmic participants in a double-blind, randomized exposure during which affective/cognitive processing was examined (i.e., emotion recognition task, emotional stroop task). Behavioral results indicate that chemosignals of aggression induce an affective/cognitive modulation compatible with an anxiety reaction in the recipients. These findings are discussed in light of mechanisms of emotional reciprocity as a way to convey not only affective but also motivational information via chemosensory signals in humans. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Control of subterranean termites (Isoptera: Rhinotermitidae) infesting power poles.
Horwood, Martin A; Westlake, Terry; Kathuria, Amrit
2010-12-01
A trial was conducted to determine the efficacy of termiticidal dusts (arsenic trioxide, triflumuron, and Metarhizium anisopliae), a timber fumigant (dazomet) and liquid termiticides (bifenthrin, chlorfenapyr, chlorpyrifos, fipronil, and imidacloprid) for controlling subterranean termites (Isoptera: Rhinotermitidae) infesting in-service power poles in New South Wales, Australia. Dusts were applied to parts of the pole where termites were present. Fumigant was inserted into holes drilled into the base of the pole. Liquid termiticides were mixed with soil around the base of the pole and injected into internal voids if present. Poles were inspected for up to 5 yr, and the time taken for reinfestation to occur was recorded. Before the start of the trial, the major Australian pole owners were surveyed to obtain an estimate of the annual national cost of termite infestation to the power supply industry. The annual costs of termite treatment and replacing damaged poles were estimated at AU$2 million and AU$13 million, respectively. Infestation rates were lower for all treatments compared with controls within the first 12 mo of the study. Dazomet, arsenic trioxide, fipronil, and chlorpyrifos were the most efficacious treatments. Efficacy was positively related to the amount of termiticide applied and negatively related to the infestation severity but was unaffected by geographical location. Survival curves were calculated of the time elapsed before the recurrence of termite infestations (survival absence of reinfestation). Survival was highest for poles treated with liquid termiticides.
Mechanical properties of small-scale laminated wood composite poles: effects of taper and webs
Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse
2006-01-01
Laminated hollow wood composite poles represent an efficient utilization of the timber resource and a promising alternative for solid poles that are commonly used in the power transmission and telecommunication lines. The objective of this study was to improve the performance of composite poles by introducing the bio-mimicry concept into the design of hollow wood...
49 CFR 236.71 - Signal wires on pole line and aerial cable.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Signal wires on pole line and aerial cable. 236.71... Instructions: All Systems Wires and Cables § 236.71 Signal wires on pole line and aerial cable. Signal wire on... pole or other support. Signal wire shall not interfere with, or be interfered by, other wires on the...
49 CFR 236.71 - Signal wires on pole line and aerial cable.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Signal wires on pole line and aerial cable. 236.71... Instructions: All Systems Wires and Cables § 236.71 Signal wires on pole line and aerial cable. Signal wire on... pole or other support. Signal wire shall not interfere with, or be interfered by, other wires on the...
NASA Astrophysics Data System (ADS)
De Vido, M.; Ertel, K.; Mason, P. D.; Banerjee, S.; Phillips, P. J.; Smith, J. M.; Butcher, T. J.; Chekhlov, O.; Divoky, M.; Pilar, J.; Hooker, C.; Shaikh, W.; Lucianetti, A.; Hernandez-Gomez, C.; Mocek, T.; Edwards, C.; Collier, J. L.
2017-02-01
In this paper, we review the development, at the STFC's Central Laser Facility (CLF), of high energy, high repetition rate diode-pumped solid-state laser (DPSSL) systems based on cryogenically-cooled multi-slab ceramic Yb:YAG. Up to date, two systems have been completed, namely the DiPOLE prototype and the DiPOLE100 system. The DiPOLE prototype has demonstrated amplification of nanosecond pulses in excess of 10 J at 10 Hz repetition rate with an opticalto- optical efficiency of 22%. The larger scale DiPOLE100 system, designed to deliver 100J temporally-shaped nanosecond pulses at 10 Hz repetition rate, has been developed at the CLF for the HiLASE project in the Czech Republic. Recent experiments conducted on the DiPOLE100 system demonstrated the energy scalability of the DiPOLE concept to the 100 J pulse energy level. Furthermore, second harmonic generation experiments carried out on the DiPOLE prototype confirmed the suitability of DiPOLE-based systems for pumping high repetition rate PW-class laser systems based on Ti:sapphire or optical parametric chirped pulse amplification (OPCPA) technology.
Self-Poling of BiFeO3 Thick Films.
Khomyakova, Evgeniya; Sadl, Matej; Ursic, Hana; Daniels, John; Malic, Barbara; Bencan, Andreja; Damjanovic, Dragan; Rojac, Tadej
2016-08-03
Bismuth ferrite (BiFeO3) is difficult to pole because of the combination of its high coercive field and high electrical conductivity. This problem is particularly pronounced in thick films. The poling, however, must be performed to achieve a large macroscopic piezoelectric response. This study presents evidence of a prominent and reproducible self-poling effect in few-tens-of-micrometer-thick BiFeO3 films. Direct and converse piezoelectric measurements confirmed that the as-sintered BiFeO3 thick films yield d33 values of up to ∼20 pC/N. It was observed that a significant self-poling effect only appears in cases when the films are heated and cooled through the ferroelectric-paraelectric phase transition (Curie temperature TC ∼ 820 °C). These self-poled films exhibit a microstructure with randomly oriented columnar grains. The presence of a compressive strain gradient across the film thickness cooled from above the TC was experimentally confirmed and is suggested to be responsible for the self-poling effect. Finally, the macroscopic d33 response of the self-poled BiFeO3 film was characterized as a function of the driving-field frequency and amplitude.
NASA Astrophysics Data System (ADS)
Carlqvist, P.; Gahm, G. F.; Kristen, H.
2003-05-01
Using the 2.6 m Nordic Optical Telescope we have observed a large number of elephant trunks in several H II regions. Here, we present a small selection of this material consisting of a few large, well-developed trunks, and some smaller ones. We find that: (i) the well-developed trunks are made up of dark filaments and knots which show evidence of twisted structures, (ii) the trunks are connected with essentially two filamentary legs running in V-shape, and (iii) all trunks have the maximum extinction in their heads. We advance a theory of twisted elephant trunks which is based on the presence of magnetic flux ropes in molecular clouds where hot OB stars are formed. If the rope contains a local condensation it may adopt a V-shape as the H II region around the hot stars expands. If, in addition, the magnetic field in the rope is sufficiently twisted, the rope may form a double helix at the apex of the V. The double helix is identified with the twisted elephant trunks. In order to illustrate the mechanisms behind the double helix we have constructed a mechanical analogy model of the magnetic flux rope in which the rope has been replaced by a bundle of elastic strings loaded by a weight. Experiments with the model clearly show that part of the bundle will transform into a double helix when the twist of the bundle is sufficiently large. We have also worked out a simple theoretical model of a mass-loaded magnetic flux rope. Numerical calculations show that a double helix will indeed form when the twist of the rope exceeds a certain critical limit. Numerical model calculations are applied to both the analogy model experiments and one of the well-developed elephant trunks. On the basis of our model we also suggest a new interpretation of the so called EGGs. The double helix mechanism is quite general, and should be active also in other suitable environments. One such environment may be the shell of supernova remnants. Another example is the expanding bubble outlined by the North Celestial Pole Loop. Based on observations collected at the Nordic Optical Telescope, La Palma, Spain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antonova, A. O., E-mail: aoantonova@mail.ru; Savyolova, T. I.
2016-05-15
A two-dimensional mathematical model of a polycrystalline sample and an experiment on electron backscattering diffraction (EBSD) is considered. The measurement parameters are taken to be the scanning step and threshold grain-boundary angle. Discrete pole figures for materials with hexagonal symmetry have been calculated based on the results of the model experiment. Discrete and smoothed (by the kernel method) pole figures of the model sample and the samples in the model experiment are compared using homogeneity criterion χ{sup 2}, an estimate of the pole figure maximum and its coordinate, a deviation of the pole figures of the model in the experimentmore » from the sample in the space of L{sub 1} measurable functions, and the RP-criterion for estimating the pole figure errors. Is is shown that the problem of calculating pole figures is ill-posed and their determination with respect to measurement parameters is not reliable.« less
Hatakeyama, Keiichi; Ohshima, Keiichi; Nagashima, Takeshi; Ohnami, Shumpei; Ohnami, Sumiko; Serizawa, Masakuni; Shimoda, Yuji; Maruyama, Koji; Akiyama, Yasuto; Urakami, Kenichi; Kusuhara, Masatoshi; Mochizuki, Tohru; Yamaguchi, Ken
2018-06-07
Defective DNA polymerase ε (POLE) proofreading leads to extensive somatic mutations that exhibit biased mutational properties; however, the characteristics of POLE-mutated tumours remain unclear. In the present study, we describe a molecular profile using whole exome sequencing based on the transition of somatic mutations in 10 POLE-mutated solid tumours that were obtained from 2,042 Japanese patients. The bias of accumulated variations in these mutants was quantified to follow a pattern of somatic mutations, thereby classifying the sequential mutation shift into three periods. During the period prior to occurrence of the aberrant POLE, bare accumulation of mutations in cancer-related genes was observed, whereas PTEN was highly mutated in conjunction with or subsequent to the event, suggesting that POLE and PTEN mutations were responsible for the development of POLE-mutated tumours. Furthermore, homologous recombination was restored following the occurrence of PTEN mutations. Our strategy for estimation of the footprint of somatic mutations may provide new insight towards the understanding of mutation-driven tumourigenesis.
Pole-Like Road Furniture Detection in Sparse and Unevenly Distributed Mobile Laser Scanning Data
NASA Astrophysics Data System (ADS)
Li, F.; Lehtomäki, M.; Oude Elberink, S.; Vosselman, G.; Puttonen, E.; Kukko, A.; Hyyppä, J.
2018-05-01
Pole-like road furniture detection received much attention due to its traffic functionality in recent years. In this paper, we develop a framework to detect pole-like road furniture from sparse mobile laser scanning data. The framework is carried out in four steps. The unorganised point cloud is first partitioned. Then above ground points are clustered and roughly classified after removing ground points. A slicing check in combination with cylinder masking is proposed to extract pole-like road furniture candidates. Pole-like road furniture are obtained after occlusion analysis in the last stage. The average completeness and correctness of pole-like road furniture in sparse and unevenly distributed mobile laser scanning data was above 0.83. It is comparable to the state of art in the field of pole-like road furniture detection in mobile laser scanning data of good quality and is potentially of practical use in the processing of point clouds collected by autonomous driving platforms.
Magnetic field adjustment structure and method for a tapered wiggler
Halbach, Klaus
1988-03-01
An improved method and structure is disclosed for adjusting the magnetic field generated by a group of electromagnet poles spaced along the path of a charged particle beam to compensate for energy losses in the charged particles which comprises providing more than one winding on at least some of the electromagnet poles; connecting one respective winding on each of several consecutive adjacent electromagnet poles to a first power supply, and the other respective winding on the electromagnet pole to a different power supply in staggered order; and independently adjusting one power supply to independently vary the current in one winding on each electromagnet pole in a group whereby the magnetic field strength of each of a group of electromagnet poles may be changed in smaller increments.
Magnetic field adjustment structure and method for a tapered wiggler
Halbach, Klaus
1988-01-01
An improved method and structure is disclosed for adjusting the magnetic field generated by a group of electromagnet poles spaced along the path of a charged particle beam to compensate for energy losses in the charged particles which comprises providing more than one winding on at least some of the electromagnet poles; connecting one respective winding on each of several consecutive adjacent electromagnet poles to a first power supply, and the other respective winding on the electromagnet pole to a different power supply in staggered order; and independently adjusting one power supply to independently vary the current in one winding on each electromagnet pole in a group whereby the magnetic field strength of each of a group of electromagnet poles may be changed in smaller increments.
Induction heating coupler and annealer
NASA Technical Reports Server (NTRS)
Fox, Robert L. (Inventor); Johnson, Samuel D. (Inventor); Copeland, Carl E. (Inventor); Coultrip, Robert H. (Inventor); Phillips, W. Morris (Inventor); Johnston, David F. (Inventor); Swaim, Robert J. (Inventor); Dinkins, James R. (Inventor)
1994-01-01
An induction heating device includes a handle having a hollow interior and two opposite ends, a wrist connected to one end of the handle, a U-shaped pole piece having- two spaced apart ends, a tank circuit including an induction coil wrapped around the pole piece and a capacitor connected to the induction coil, a head connected to the wrist and including a housing for receiving the U-shaped pole piece, the two spaced apart ends of the pole piece extending outwardly beyond the housing, and a power source connected to the tank circuit. When the tank circuit is energized and a susceptor is placed in juxtaposition to the ends of the U-shaped pole piece, the susceptor is heated by induction heating due to a magnetic flux passing between the two ends of the pole piece.
NASA Technical Reports Server (NTRS)
Fox, Robert L. (Inventor); Copeland, Carl E. (Inventor); Swaim, Robert J. (Inventor); Coultrip, Robert H. (Inventor); Johnston, David F. (Inventor); Phillips, W. Morris (Inventor); Johnson, Samuel D. (Inventor); Dinkins, James R. (Inventor); Buckley, John D. (Inventor)
1994-01-01
An induction heating device includes a handle having a hollow interior and two opposite ends, a wrist connected to one end of the handle, a U-shaped pole piece having two spaced apart ends, a tank circuit including an induction coil wrapped around the pole piece and a capacitor connected to the induction coil, a head connected to the wrist and including a housing for receiving the U-shaped pole piece, the two spaced apart ends of the pole piece extending outwardely beyond the housing, and a power source connected to the tank circuit. When the tank circuit is energized and a susceptor is placed in juxtaposition to the ends of the U-shaped pole piece, the susceptor is heated by induction heating due to magnetic flux passing between the two ends of the pole piece.
STS-58 crewmembers participate in baseline data collection
1993-09-29
S93-45371 (29 Sept 1993) --- Astride the bicycle ergometer, Martin J. (Marty) Fettman, DVM, breathes quietly into the cardiovascular re-breathing unit during the resting phase of an experiment. The payload specialist for the Spacelab Life Sciences (SLS-2) mission was participating with six NASA astronauts, also assigned to STS-58, for data collection and training.
Cardio-Respiratory Responses to Maximal Work During Arm and Bicycle Ergometry.
ERIC Educational Resources Information Center
Israel, Richard G.; Hardison, George T.
This study compared cardio-respiratory responses during maximal arm work using a Monarch Model 880 Rehab Trainer to cardio-respiratory responses during maximal leg work on a Monarch Model 850 Bicycle Ergometer. Subjects for the investigation were 17 male university students ranging from 18 to 28 years of age. The specific variables compared…
Dahl, Christine; Sandbakk, Øyvind; Danielsen, Jørgen; Ettema, Gertjan
2017-01-01
In classical cross-country skiing, diagonal stride (DIA) is the major uphill sub-technique, while double poling (DP) is used on relatively flat terrain. Although, the dependence of incline and speed on the preference of either sub-technique seems clearly established, the mechanisms behind these preferences are not clear. Therefore, the purpose of this study was to compare kinetics and energy consumption in DP and DIA at the same submaximal workload in cross-country skiing under two different incline-speed combinations. We compared kinetics and physiological responses in DP and DIA at the same submaximal workload (≈200 W) under two different incline-speed conditions, (5%—12.5 km h−1 vs. 12%—6.5 km h−1) where DP and DIA were expected to be preferred, respectively. Fifteen elite male cross-country skiers performed four separate 6.5-min roller skiing sessions on a treadmill at these two conditions using DP and DIA during which physiological variables, rate of perceived exertion (RPE) and kinetics, including power fluctuations, were recorded. At 12% incline, DIA resulted in lower physiological response (e.g., heart rate) and RPE, and higher gross efficiency than DP, whereas at 5% incline these variables favored DP (P < 0.05). The skiers' preference for sub-technique (13 preferred DIA at 12% incline; all 15 preferred DP at 5% incline) was in accordance with these results. Fluctuation in instantaneous power was lowest in the preferred sub-technique at each condition (P < 0.05). Preference for DP at 5% incline (high speed) is most likely because the speed is too high for effective ski thrust in DIA, which is reflected in high power fluctuations. The mechanism for preference of DIA at 12% incline is not indicated directly by the current data set showing only small differences in power fluctuations between DIA and DP. Apart from the low speed allowing ski thrust, we suggest that restricted ability to utilize the body's mechanical energy as well as the use of arms in DP play an important role. PMID:28270769
Dahl, Christine; Sandbakk, Øyvind; Danielsen, Jørgen; Ettema, Gertjan
2017-01-01
In classical cross-country skiing, diagonal stride (DIA) is the major uphill sub-technique, while double poling (DP) is used on relatively flat terrain. Although, the dependence of incline and speed on the preference of either sub-technique seems clearly established, the mechanisms behind these preferences are not clear. Therefore, the purpose of this study was to compare kinetics and energy consumption in DP and DIA at the same submaximal workload in cross-country skiing under two different incline-speed combinations. We compared kinetics and physiological responses in DP and DIA at the same submaximal workload (≈200 W) under two different incline-speed conditions, (5%-12.5 km h -1 vs. 12%-6.5 km h -1 ) where DP and DIA were expected to be preferred, respectively. Fifteen elite male cross-country skiers performed four separate 6.5-min roller skiing sessions on a treadmill at these two conditions using DP and DIA during which physiological variables, rate of perceived exertion ( RPE ) and kinetics, including power fluctuations, were recorded. At 12% incline, DIA resulted in lower physiological response (e.g., heart rate) and RPE , and higher gross efficiency than DP, whereas at 5% incline these variables favored DP ( P < 0.05). The skiers' preference for sub-technique (13 preferred DIA at 12% incline; all 15 preferred DP at 5% incline) was in accordance with these results. Fluctuation in instantaneous power was lowest in the preferred sub-technique at each condition ( P < 0.05). Preference for DP at 5% incline (high speed) is most likely because the speed is too high for effective ski thrust in DIA, which is reflected in high power fluctuations. The mechanism for preference of DIA at 12% incline is not indicated directly by the current data set showing only small differences in power fluctuations between DIA and DP. Apart from the low speed allowing ski thrust, we suggest that restricted ability to utilize the body's mechanical energy as well as the use of arms in DP play an important role.
Stöggl, Thomas; Welde, Boye; Supej, Matej; Zoppirolli, Chiara; Rolland, Carsten G; Holmberg, Hans-Christer; Pellegrini, Barbara
2018-03-01
Here, female and male elite cross-country (XC) skiers were compared on varying terrain during an official 10-km (women) and 15-km (men) Norwegian championship race. On the basis of race performance, 82 skiers were classified as fast (FS) (20 women, 20 men) or slower (SS) (21, 21) skiers. All were video recorded on flat (0°), intermediate (3.5°), uphill (7.1°) and steep uphill (11°) terrain during the race at a distance of 0.8, 1.2, 2.1 and 7.1 km from the start, respectively. All skiers employed exclusively double-poling (DP) on the flat section and, except for the male winner, exclusively diagonal stride (DIA) on the uphill sections. On the intermediate section, more men than women utilized DP and fewer DIA (p = 0.001), with no difference in kick double-poling (DPK). More FS than SS utilized DPK and fewer DIA (p = 0.001), with similar usage of DP. Males skied with faster and longer cycles but lower cycle rate compared with females (p < 0.001), with largest absolute sex differences on flat terrain (p < 0.001) and largest relative differences for cycle velocity and length on intermediate and uphill terrain. External power output rose with increasing incline, being higher for men and FS (p < 0.001). Cycle velocity on flat terrain was the best predictor of mean race velocity for the men, while cycle velocity on steep uphill was the best predictor for the women (both p < 0.001). In conclusion, incline, sex and level of performance influenced cycle characteristics and power output. Greatest absolute sex gap was on flat terrain, whereas the relative difference was greatest on intermediate and steep uphill terrain. We recommend usage of more DP and/or DPK, and less DIA and fewer transitions between techniques on intermediate terrain. Predictors of race performance are sex specific with greatest potential for enhancing performance on flat terrain for men and on steep uphill terrain for women.
Huaqiang Yu; Chung Y. Hse; Zehui Jiang
2009-01-01
The wood poles in the United States are from high-valued trees that are becoming more expensive and less available. Wood laminated composite poles (LCP) are a kind of alternative to solid poles. Considerable interest has developed in last century in the resin impregnation and wood surface densification to improve its physical and mechanical properties. In this...
Effect of Materials and Manufacturing on the Bending Stiffness of Vaulting Poles
ERIC Educational Resources Information Center
Davis, C. L.; Kukureka, S. N.
2012-01-01
The increase in the world record height achieved in pole vaulting can be related to the improved ability of the athletes, in terms of their fitness and technique, and to the change in materials used to construct the pole. For example in 1960 there was a change in vaulting pole construction from bamboo to glass fibre reinforced polymer (GFRP)…
Cheng Piao; Todd F. Shupe; R.C. Tang; Chung Y. Hse
2008-01-01
Tapered composite poles with biomimicry features as in bamboo are a new generation of wood laminated composite poles that may some day be considered as an alternative to solid wood poles that are widely used in the transmission and telecommunication fields. Five finite element models were developed with ANSYS to predict and assess the performance of five types of...
Prognostic Significance of POLE Proofreading Mutations in Endometrial Cancer
Church, David N.; Stelloo, Ellen; Nout, Remi A.; Valtcheva, Nadejda; Depreeuw, Jeroen; ter Haar, Natalja; Noske, Aurelia; Amant, Frederic; Wild, Peter J.; Lambrechts, Diether; Jürgenliemk-Schulz, Ina M.; Jobsen, Jan J.; Smit, Vincent T. H. B. M.; Creutzberg, Carien L.; Bosse, Tjalling
2015-01-01
Background: Current risk stratification in endometrial cancer (EC) results in frequent over- and underuse of adjuvant therapy, and may be improved by novel biomarkers. We examined whether POLE proofreading mutations, recently reported in about 7% of ECs, predict prognosis. Methods: We performed targeted POLE sequencing in ECs from the PORTEC-1 and -2 trials (n = 788), and analyzed clinical outcome according to POLE status. We combined these results with those from three additional series (n = 628) by meta-analysis to generate multivariable-adjusted, pooled hazard ratios (HRs) for recurrence-free survival (RFS) and cancer-specific survival (CSS) of POLE-mutant ECs. All statistical tests were two-sided. Results: POLE mutations were detected in 48 of 788 (6.1%) ECs from PORTEC-1 and-2 and were associated with high tumor grade (P < .001). Women with POLE-mutant ECs had fewer recurrences (6.2% vs 14.1%) and EC deaths (2.3% vs 9.7%), though, in the total PORTEC cohort, differences in RFS and CSS were not statistically significant (multivariable-adjusted HR = 0.43, 95% CI = 0.13 to 1.37, P = .15; HR = 0.19, 95% CI = 0.03 to 1.44, P = .11 respectively). However, of 109 grade 3 tumors, 0 of 15 POLE-mutant ECs recurred, compared with 29 of 94 (30.9%) POLE wild-type cancers; reflected in statistically significantly greater RFS (multivariable-adjusted HR = 0.11, 95% CI = 0.001 to 0.84, P = .03). In the additional series, there were no EC-related events in any of 33 POLE-mutant ECs, resulting in a multivariable-adjusted, pooled HR of 0.33 for RFS (95% CI = 0.12 to 0.91, P = .03) and 0.26 for CSS (95% CI = 0.06 to 1.08, P = .06). Conclusion: POLE proofreading mutations predict favorable EC prognosis, independently of other clinicopathological variables, with the greatest effect seen in high-grade tumors. This novel biomarker may help to reduce overtreatment in EC. PMID:25505230
Influence of kinematic parameters on pole vault results in top juniors.
Gudelj, Ines; Zagorac, Nebojsa; Babić, Vesna
2013-05-01
The aim of this research was to analyse the kinematic parameters and to ascertain the influence of those parameters on the pole vault result. The entity sample of the research consisted of successful vaults of 30 athletes, whose attempts were recorded at the European Junior Athletics Championships. The examinees performed the vaults as part of the qualification competition for the finale and the finale of the competition itself The examinees were 17-19 years old, and the range of their top results was from 4.90 to 5.30 m. The results of the regression analysis showed a significant influence of the predictor variables on the effective pole vault height. The centre of body mass height was mostly influenced by the following variables: TS - takeoff velocity, LSS - last step velocity, PSS - penultimate step velocity, TAPR - trunk angle at the moment of the pole release. The following variables had lesser, but still a significant influence: CBMDM - centre of body mass distance at the pole release moment, and MCMVV - time of pole straightening. Generally, the information gained by this research indicates the significant influence of the kinematic parameters on the pole vault result. Therefore, the conclusion is that the result efficacy in the pole vault is primarily determined by the variables defined by the motor capabilities, but also by the indicators determining the vault activity realization technique. The variables that define the body position during the pole release (trunk angle and centre of mass distance) have heomost significant influence on the vault performance technique, while the motor capabilities influence the last two run up steps velocity, take off speed and the time of pole straightening.
Diagnostics of Wooden Poles Situated in the Open - Air Museum Using Sonic Tomography
NASA Astrophysics Data System (ADS)
Makýš, Oto; Krušinský, Peter; Korenková, Renáta; Šrobárová, Dominika
2018-06-01
The paper deals with the lifetime of wooden poles, situated in the archaeological open-air museum Liptovská Mara - Havránok, which were erected outdoors about 12 years ago. It is aimed at diagnosing their condition using sonic tomography. The poles differ from each other in the location, anchorage, and positioning in terms of the terrain slope. Investigation was focused on the free-standing poles (quasi sacrifice poles) and the poles that are part of the fortification (gates and walls). Measurements were carried out using the device Fakopp ArborSonic 3D Sonic Tomograph that has 18 sensors. It measures the sonic response (sound velocity) in a tree stem. Sound wave velocity within sound wood depends on its species, moisture content, and the direction of measurement. Measurements brought remarkable results.
Pole orientation of 16 Psyche by two independent methods
NASA Technical Reports Server (NTRS)
Tedesco, E. F.; Taylor, R. C.
1985-01-01
Nineteen new lightcurves of 16 Psyche are presented along with a pole orientation derived using two independent methods, namely, photometric astrometry and magnitude-amplitude-shape-aspect. The pole orientations found using these two methods agree to within 4 deg. The results from applying photometric astrometry were prograde rotation, a sidereal period of 0.1748143 days + or - 0.0000003 days, and a pole at longitude 223 deg and latitude +37 deg, with an uncertainty of 10 deg, and, from applying magnitude-amplitude-shape-aspect a pole at 220 + or - 1 deg, +40 + or - 4 deg, and a modeled triaxial ellipsoid shape (a greater than b greater than c) and a/b = 1.33 + or - 0.07. The discrepancy between the high-pole latitude found here and the low latitudes reported by Lupishko et al. (1982) and Zhou and Yang (1982) is discussed.
Designated fiber stress for wood poles
Ronald W. Wolfe; Robert O. Kluge
2005-01-01
Wood poles have been used to support utility distribution lines for well over 100 years. Over that time, specifications for a âwood utility poleâ have evolved from the closest available tree stem more than 15 ft in length to straight, durable timbers of lengths ranging up 125 ft and base diameters of as much as 27 in. The continued success of wood poles in this...
Ocean floor mounting of wave energy converters
Siegel, Stefan G
2015-01-20
A system for mounting a set of wave energy converters in the ocean includes a pole attached to a floor of an ocean and a slider mounted on the pole in a manner that permits the slider to move vertically along the pole and rotate about the pole. The wave energy converters can then be mounted on the slider to allow adjustment of the depth and orientation of the wave energy converters.
Standard, Random, and Optimum Array conversions from Two-Pole resistance data
Rucker, D. F.; Glaser, Danney R.
2014-09-01
We present an array evaluation of standard and nonstandard arrays over a hydrogeological target. We develop the arrays by linearly combining data from the pole-pole (or 2-pole) array. The first test shows that reconstructed resistances for the standard Schlumberger and dipoledipole arrays are equivalent or superior to the measured arrays in terms of noise, especially at large geometric factors. The inverse models for the standard arrays also confirm what others have presented in terms of target resolvability, namely the dipole-dipole array has the highest resolution. In the second test, we reconstruct random electrode combinations from the 2-pole data segregated intomore » inner, outer, and overlapping dipoles. The resistance data and inverse models from these randomized arrays show those with inner dipoles to be superior in terms of noise and resolution and that overlapping dipoles can cause model instability and low resolution. Finally, we use the 2-pole data to create an optimized array that maximizes the model resolution matrix for a given electrode geometry. The optimized array produces the highest resolution and target detail. Thus, the tests demonstrate that high quality data and high model resolution can be achieved by acquiring field data from the pole-pole array.« less
Evaluation of three elevated mist-net systems for sampling birds
Meyers, J.M.; Pardieck, K.L.
1993-01-01
Three light-weight, low-canopy mist-net systems were developed and tested in dry tropical scrub, mangrove and forest habitats. One plastic (polyvinyl chloride) and two aluminum pole systems (with and without pulleys) were used to support mist nets to heights of up to 7.3 m. Although the aluminum telescoping-pole system (without pulleys) was expensive initially ( 79-141/unit (US)), its use reduced capture of nontarget species and may have increased capture of target species when compared with ground-level netting. In one year, its use also reduced labor costs by 756, which completely offset the higher cost of the aluminum telescoping-pole system when compared to the plastic-pole system ( 19/unit). Unlike the plastic-pole system, the aluminum telescoping-pole system was adjustable to any height within its range of 1.8 to 7.3 m, was 1.5 m higher, was more efficient to operate in the field, and was easily moved to new locations. For capture of psittacines, the pulleys of the aluminum telescoping-pole system were not necessary, but their use may assist in efficiently retrieving large numbers of birds from the nets. The aluminum telescoping-pole system was efficient in capturing psittacines, columbids, passerines and possibly chiropterans in habitats with canopies lt 10 m or in the forest subcanopy.
DOT National Transportation Integrated Search
2001-02-01
Maine was recently ranked 9th in the nation concerning fatalities caused by collisions with utility poles based on : Miles of Travel. The number of collisions and fatalities can be reduced significantly with an updated Utility Pole : Placement Policy...
Fatigue failure and cracking in high mast poles.
DOT National Transportation Integrated Search
2012-03-01
This report presents the findings of a comprehensive research project to investigate the fatigue : cracking and failure of galvanized high mast illumination poles (HMIP). Ultrasonic inspection of : poles throughout the state has revealed the presence...
Csonka, P.L.; Tatchyn, R.O.
1989-01-24
Micropole undulators for use in the generation of x-rays from moving charged particles and methods for manufacturing such undulators are disclosed. One type of micropole undulator has two jaws containing rows of spaced apart poles arranged so that each pole produces a magnetic field aligned with all other similar fields. An external biasing field extends through the jaws so that an overall undulator field of substantially sinusoidal shape and substantially zero average value extends along the undulator axis. Preferably, the poles are bars formed of a magnetizable, but unmagnetized, material so that, after the jaws are assembled, all of the bars can be magnetized simultaneously in a uniform magnetic field of suitable strength. Another type of micropole undulator incorporates two parallel layers which have been magnetized to provide rows of alternating magnetic fields extending in opposite directions, the layers being positioned between the pole faces of a highly magnetically permeable material with the south poles of one layer opposite the north poles of the other. Poles in the layers are formed by subjecting successive regions of each layer to oppositely directed and suitably varied magnetizing forces. 16 figs.
Csonka, Paul L.; Tatchyn, Roman O.
1989-01-24
Micropole undulators for use in the generation of x-rays from moving charged particles and methods for manufacturing such undulators are disclosed. One type of micropole undulator has two jaws containing rows of spaced apart poles arranged so that each pole produces a magnetic field aligned with all other similar fields. An external biasing field extends through the jaws so that an overall undulator field of substantially sinusoidal shape and substantially zero average value extends along the undulator axis. Preferably, the poles are bars formed of a magnetizable, but unmagnetized, material so that, after the jaws are assembled, all of the bars can be magnetized simultaneously in a uniform magnetic field of suitable strength. Another type of micropole undulator incorporates two parallel layers which have been magnetized to provide rows of alternating magnetic fields extending in opposite directions, the layers being positioned between the pole faces of a highly magnetically permeable material with the south poles of one layer opposite the north poles of the other. Poles in the layers are formed by subjecting successive regions of each layer to oppositely directed and suitably varied magnetizing forces.
Chromophore Poling in Thin Films of Organic Glasses. 2. Two-Electrode Corona Discharge Setup
NASA Astrophysics Data System (ADS)
Vilitis, O.; Muzikante, I.; Rutkis, M.; Vembris, A.
2012-01-01
In Part 1 of the article we provided description of the corona discharge physics and overview of the methods used for corona poling in thin organic films. Subsequent sections describe comparatively simple technical methods for poling the organic nonlinear optical polymers using a two-electrode (point-to-plate or wire-to-plate) technique. The polarization build-up was studied by the DC positive corona method for poling the nonlinear optical (NLO) polymers. The experimental setup provides the corona discharge current from 0.5 μA up to 3 μA by applying 3 kV - 12 kV voltage to the corona electrode and makes possible selection among the types of corona electrodes (needle, multi-needle, wire, etc.). The results of experimental testing of the poling setup show that at fixed optimal operational parameters of poling - the sample orientation temperature and the discharge current - the corona charging of polymeric materials can successfully be performed applying the two-electrode technique. To study the dynamics of both poling and charge transport processes the three-electrode charging system - a corona triode - should be applied.
Psilocybin modulates functional connectivity of the amygdala during emotional face discrimination.
Grimm, O; Kraehenmann, R; Preller, K H; Seifritz, E; Vollenweider, F X
2018-04-24
Recent studies suggest that the antidepressant effects of the psychedelic 5-HT2A receptor agonist psilocybin are mediated through its modulatory properties on prefrontal and limbic brain regions including the amygdala. To further investigate the effects of psilocybin on emotion processing networks, we studied for the first-time psilocybin's acute effects on amygdala seed-to-voxel connectivity in an event-related face discrimination task in 18 healthy volunteers who received psilocybin and placebo in a double-blind balanced cross-over design. The amygdala has been implicated as a salience detector especially involved in the immediate response to emotional face content. We used beta-series amygdala seed-to-voxel connectivity during an emotional face discrimination task to elucidate the connectivity pattern of the amygdala over the entire brain. When we compared psilocybin to placebo, an increase in reaction time for all three categories of affective stimuli was found. Psilocybin decreased the connectivity between amygdala and the striatum during angry face discrimination. During happy face discrimination, the connectivity between the amygdala and the frontal pole was decreased. No effect was seen during discrimination of fearful faces. Thus, we show psilocybin's effect as a modulator of major connectivity hubs of the amygdala. Psilocybin decreases the connectivity between important nodes linked to emotion processing like the frontal pole or the striatum. Future studies are needed to clarify whether connectivity changes predict therapeutic effects in psychiatric patients. Copyright © 2018 Elsevier B.V. and ECNP. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaboli, Shirin; Burnley, Pamela C.
Rhombohedral twinning in alumina (aluminium oxide, α-Al 2O 3) is an important mechanism for plastic deformation under high-temperature–pressure conditions. Rhombohedral twins in a polycrystalline alumina sample deformed in a D-DIA apparatus at 965 K and 4.48 GPa have been characterized. Three classes of grains were imaged, containing single, double and mosaic twins, using electron channeling contrast imaging (ECCI) in a field emission scanning electron microscope. These twinned grains were analyzed using electron backscatter diffraction (EBSD). The methodology for twin identification presented here is based on comparison of theoretical pole figures for a rhombohedral twin with experimental pole figures obtained withmore » EBSD crystal orientation mapping. An 85°(02{\\overline 2}1) angle–axis pair of misorientation was identified for rhombohedral twin boundaries in alumina, which can be readily used in EBSD post-processing software to identify the twin boundaries in EBSD maps and distinguish the rhombohedral twins from basal twins. Elastic plastic self-consistent (EPSC) modeling was then used to model the synchrotron X-ray diffraction data from the D-DIA experiments utilizing the rhombohedral twinning law. From these EPSC models, a critical resolved shear stress of 0.25 GPa was obtained for rhombohedral twinning under the above experimental conditions, which is internally consistent with the value estimated from the applied load and Schmid factors determined by EBSD analysis.« less
Static Multiple-Pole Homopolar Generator With a Superconducting Screen,
1983-11-03
STANAR193-A OlCFILE GORY 00 FOREIGN TECHNOLOGY DIVISION STATIC MULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPERC9ONDUCTING SCREEN by V.P. Kartsev, avld...November 1983 MICROFICHE MJR: FTD-83-C-001336 STATIC %fULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPRCONDUCTING SCREEN By: V.P. Kartsev, and I.M. Yegorov...this translation were extracted from the best quality copy available. STATIC MULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPERCONDUCTING SCREEN V.P
MOLA: Seasonal Snow Variations on Mars: Slow Flyover of the Martian North Pole
NASA Technical Reports Server (NTRS)
2001-01-01
MOLA: Seasonal Snow Variations on Mars: Slow Flyover of the Martian North Pole: False Color. This is a visualization of the topography near the Martian north pole as measured with the MOLA instrument. This particular animation shows a slow zoom to the surface of the pole, a flyover of the polar cap and a slow zoom out. The surface color is based on the elevation of the topography.
DESIGN CONCEPT FOR AN ELEVATED SOUTH POLE STATION.
Because of the failing condition of the present South Pole Station and the need for a station with a minimum life of 15 years, in 1960 the Laboratory...was requested to study design concepts for the South Pole Station. All concepts were to be com patible with the logistical and natural problems...composite design was selected as the most promising for the South Pole Station. Following this selection, a conceptual design was developed. The
Baryon transition form factors at the pole
Tiator, L.; Döring, M.; Workman, R. L.; ...
2016-12-21
Electromagnetic resonance properties are uniquely defined at the pole and do not depend on the separation of the resonance from background or the decay channel. Photon-nucleon branching ratios are nowadays often quoted at the pole, and we generalize the considerations to the case of virtual photons. In this paper, we derive and compare relations for nucleon to baryon transition form factors both for the Breit-Wigner and the pole positions. Using the MAID2007 and SAID SM08 partial wave analyses of pion electroproduction data, we compare themore » $$G_M$$, $$G_E$$, and $$G_C$$ form factors for the $$\\Delta(1232)$$ resonance excitation at the Breit-Wigner resonance and pole positions up to $Q^2=5$ GeV$^2$. We also explore the $E/M$ and $S/M$ ratios as functions of $Q^2$. Finally, for pole and residue extraction, we apply the Laurent + Pietarinen method.« less
Axial flux machine, stator and fabrication method
Carl, Ralph James
2004-03-16
An axial flux machine comprises: a soft magnetic composite stator extension positioned in parallel with a rotor disk and having slots; soft magnetic composite pole pieces attached to the stator extension and facing a permanent magnet on the rotor disk, each comprising a protrusion situated within a respective one of the slots, each protrusion shaped so as to facilitate orientation of the respective pole piece with respect to the stator extension; electrical coils, each wrapped around a respective one of the pole pieces. In another embodiment the soft magnetic composite pole pieces each comprise a base portion around with the electrical coils are wound and a trapezoidal shield portion a plurality of heights with a first height in a first region being longer than a second height in a second region, the second region being closer to a pole-to-pole gap than the first region.
NASA Technical Reports Server (NTRS)
Sieradski, L. M.; Giffin, C. E.; Nier, A. O. (Inventor)
1976-01-01
A mass spectrometer (MS) with unique magnetic pole pieces which provide a homogenous magnetic field across the gap of the MS magnetic sector as well as the magnetic field across an ion-type vacuum pump is disclosed. The pole pieces form the top and bottom sides of a housing. The housing is positioned so that portions of the pole pieces form part of the magnetic sector with the space between them defining the gap region of the magnetic sector, through which an ion beam passes. The pole pieces extend beyond the magnetic sector with the space between them being large enough to accommodate the electrical parts of an ion-type vacuum pump. The pole pieces which provide the magnetic field for the pump, together with the housing form the vacuum pump enclosure or housing.
Baryon transition form factors at the pole
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tiator, L.; Döring, M.; Workman, R. L.
Electromagnetic resonance properties are uniquely defined at the pole and do not depend on the separation of the resonance from background or the decay channel. Photon-nucleon branching ratios are nowadays often quoted at the pole, and we generalize the considerations to the case of virtual photons. In this paper, we derive and compare relations for nucleon to baryon transition form factors both for the Breit-Wigner and the pole positions. Using the MAID2007 and SAID SM08 partial wave analyses of pion electroproduction data, we compare themore » $$G_M$$, $$G_E$$, and $$G_C$$ form factors for the $$\\Delta(1232)$$ resonance excitation at the Breit-Wigner resonance and pole positions up to $Q^2=5$ GeV$^2$. We also explore the $E/M$ and $S/M$ ratios as functions of $Q^2$. Finally, for pole and residue extraction, we apply the Laurent + Pietarinen method.« less
Membrane recycling at the infranuclear pole of the outer hair cell
NASA Astrophysics Data System (ADS)
Harasztosi, Csaba; Harasztosi, Emese; Gummer, Anthony W.
2015-12-01
Rapid endocytic activity of outer hair cells (OHCs) in the guinea-pig cochlea has been already studied using the fluorescent membrane marker FM1-43. It was demonstrated that vesicles were endocytosed at the apical pole of OHCs and transcytosed to the basolateral membrane and through a central strand towards the nucleus. The significance of endocytic activity in the infranuclear region is still not clear. Therefore, in this study endocytic activity at the synaptic pole of OHCs was investigated. Confocal laser scanning microscopy was used to visualize dye uptake of OHCs isolated from the guinea-pig cochlea. Signal intensity changes were quantified in the apical and basal poles relative to the signal at the membrane. Data showed no significant difference in fluorescent signal intensity changes between the opposite poles of the OHC. These results suggest that endocytic activities in both the basal and the apical poles contribute equally to the membrane recycling of OHCs.
NASA Technical Reports Server (NTRS)
Hockney, Richard L. (Inventor); Downer, James R. (Inventor); Eisenhaure, David B. (Inventor); Hawkey, Timothy J. (Inventor); Johnson, Bruce G. (Inventor)
1990-01-01
A magnetic bearing system for enabling translational motion includes a carriage and a shaft for movably supporting the carriage; a first magnetic bearing fixed to one of the carriage and shaft and slidably received in a first channel of the other of the carriage and shaft. The first channel is generally U shaped with two side walls and a back wall. The magnetic bearing includes a pair of spaced magnetic pole pieces, each pole piece having a pair of electromagnetic coils mounted on poles on opposite ends of the pole piece proximate the side walls, and a third electromagnetic coil mounted on a pole of the pole piece proximate the backwall; a motion sensor for sensing translational motion along two axes and rotationally about three axes of the carriage and shaft relative to each other; and a correction circuit responsive to the sensor for generating a correction signal to drive the coils to compensate for any misalignment sensed between the carriage and the shaft.
High bandwidth underwater optical communication.
Hanson, Frank; Radic, Stojan
2008-01-10
We report error-free underwater optical transmission measurements at 1 Gbit/s (10(9) bits/s) over a 2 m path in a laboratory water pipe with up to 36 dB of extinction. The source at 532 nm was derived from a 1064 nm continuous-wave laser diode that was intensity modulated, amplified, and frequency doubled in periodically poled lithium niobate. Measurements were made over a range of extinction by the addition of a Mg(OH)(2) and Al(OH)(3) suspension to the water path, and we were not able to observe any evidence of temporal pulse broadening. Results of Monte Carlo simulations over ocean water paths of several tens of meters indicate that optical communication data rates >1 Gbit/s can be supported and are compatible with high-capacity data transfer applications that require no physical contact.
NASA Astrophysics Data System (ADS)
Wang, Junmin; Zhang, Kong; Ge, Yulong; Guo, Shanlong
2016-06-01
We have demonstrated 1.61 W of 780 nm single-frequency continuous-wave laser output with a semi-monolithic periodically poled potassium titanyl phosphate (PPKTP) crystal doubler pumped by a 2-W erbium-doped fiber amplifier boosted 1560 nm diode laser. The measured maximum doubling efficiency is 77%, and the practical value should be 80% when taking into account the fundamental-wave mode matching efficiency. The measured beam quality factor of 780 nm output, M2, is better than 1.04. Typical root-mean-square fluctuation of 780 nm output is less than 0.5% in 30 minutes. This compact frequency doubler has good mechanical stability, and can be employed for many applications, such as laser cooling and trapping, atomic coherent control, atomic interferometer, and quantum frequency standard with rubidium atoms.
Cogging Torque Minimization in Transverse Flux Machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz
2017-02-16
This paper presents the design considerations in cogging torque minimization in two types of transverse flux machines. The machines have a double stator-single rotor configuration with flux concentrating ferrite magnets. One of the machines has pole windings across each leg of an E-Core stator. Another machine has quasi-U-shaped stator cores and a ring winding. The flux in the stator back iron is transverse in both machines. Different methods of cogging torque minimization are investigated. Key methods of cogging torque minimization are identified and used as design variables for optimization using a design of experiments (DOE) based on the Taguchi method.more » A three-level DOE is performed to reach an optimum solution with minimum simulations. Finite element analysis is used to study the different effects. Two prototypes are being fabricated for experimental verification.« less