Sample records for double-difference tomography method

  1. An efficient algorithm for double-difference tomography and location in heterogeneous media, with an application to the Kilauea volcano

    USGS Publications Warehouse

    Monteiller, V.; Got, J.-L.; Virieux, J.; Okubo, P.

    2005-01-01

    Improving our understanding of crustal processes requires a better knowledge of the geometry and the position of geological bodies. In this study we have designed a method based upon double-difference relocation and tomography to image, as accurately as possible, a heterogeneous medium containing seismogenic objects. Our approach consisted not only of incorporating double difference in tomography but also partly in revisiting tomographic schemes for choosing accurate and stable numerical strategies, adapted to the use of cross-spectral time delays. We used a finite difference solution to the eikonal equation for travel time computation and a Tarantola-Valette approach for both the classical and double-difference three-dimensional tomographic inversion to find accurate earthquake locations and seismic velocity estimates. We estimated efficiently the square root of the inverse model's covariance matrix in the case of a Gaussian correlation function. It allows the use of correlation length and a priori model variance criteria to determine the optimal solution. Double-difference relocation of similar earthquakes is performed in the optimal velocity model, making absolute and relative locations less biased by the velocity model. Double-difference tomography is achieved by using high-accuracy time delay measurements. These algorithms have been applied to earthquake data recorded in the vicinity of Kilauea and Mauna Loa volcanoes for imaging the volcanic structures. Stable and detailed velocity models are obtained: the regional tomography unambiguously highlights the structure of the island of Hawaii and the double-difference tomography shows a detailed image of the southern Kilauea caldera-upper east rift zone magmatic complex. Copyright 2005 by the American Geophysical Union.

  2. Probing the Detailed Seismic Velocity Structure of Subduction Zones Using Advanced Seismic Tomography Methods

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Thurber, C. H.

    2005-12-01

    Subduction zones are one of the most important components of the Earth's plate tectonic system. Knowing the detailed seismic velocity structure within and around subducting slabs is vital to understand the constitution of the slab, the cause of intermediate depth earthquakes inside the slab, the fluid distribution and recycling, and tremor occurrence [Hacker et al., 2001; Obara, 2002].Thanks to the ability of double-difference tomography [Zhang and Thurber, 2003] to resolve the fine-scale structure near the source region and the favorable seismicity distribution inside many subducting slabs, it is now possible to characterize the fine details of the velocity structure and earthquake locations inside the slab, as shown in the study of the Japan subduction zone [Zhang et al., 2004]. We further develop the double-difference tomography method in two aspects: the first improvement is to use an adaptive inversion mesh rather than a regular inversion grid and the second improvement is to determine a reliable Vp/Vs structure using various strategies rather than directly from Vp and Vs [see our abstract ``Strategies to solve for a better Vp/Vs model using P and S arrival time'' at Session T29]. The adaptive mesh seismic tomography method is based on tetrahedral diagrams and can automatically adjust the inversion mesh according to the ray distribution so that the inversion mesh nodes are denser where there are more rays and vice versa [Zhang and Thurber, 2005]. As a result, the number of inversion mesh nodes is greatly reduced compared to a regular inversion grid with comparable spatial resolution, and the tomographic system is more stable and better conditioned. This improvement is quite valuable for characterizing the fine structure of the subduction zone considering the highly uneven distribution of earthquakes within and around the subducting slab. The second improvement, to determine a reliable Vp/Vs model, lies in jointly inverting Vp, Vs, and Vp/Vs using P, S, and S-P times in a manner similar to double-difference tomography. Obtaining a reliable Vp/Vs model of the subduction zone is more helpful for understanding its mechanical and petrologic properties. Our applications of the original version of double-difference tomography to several subduction zones beneath northern Honshu, Japan, the Wellington region, New Zealand, and Alaska, United States, have shown evident velocity variations within and around the subducting slab, which likely is evidence of dehydration reactions of various hydrous minerals that are hypothesized to be responsible for intermediate depth earthquakes. We will show the new velocity models for these subduction zones by applying our advanced tomographic methods.

  3. Double-Difference Global Adjoint Tomography

    NASA Astrophysics Data System (ADS)

    Orsvuran, R.; Bozdag, E.; Lei, W.; Tromp, J.

    2017-12-01

    The adjoint method allows us to incorporate full waveform simulations in inverse problems. Misfit functions play an important role in extracting the relevant information from seismic waveforms. In this study, our goal is to apply the Double-Difference (DD) methodology proposed by Yuan et al. (2016) to global adjoint tomography. Dense seismic networks, such as USArray, lead to higher-resolution seismic images underneath continents. However, the imbalanced distribution of stations and sources poses challenges in global ray coverage. We adapt double-difference multitaper measurements to global adjoint tomography. We normalize each DD measurement by its number of pairs, and if a measurement has no pair, as may frequently happen for data recorded at oceanic stations, classical multitaper measurements are used. As a result, the differential measurements and pair-wise weighting strategy help balance uneven global kernel coverage. Our initial experiments with minor- and major-arc surface waves show promising results, revealing more pronounced structure near dense networks while reducing the prominence of paths towards cluster of stations. We have started using this new measurement in global adjoint inversions, addressing azimuthal anisotropy in upper mantle. Meanwhile, we are working on combining the double-difference approach with instantaneous phase measurements to emphasize contributions of scattered waves in global inversions and extending it to body waves. We will present our results and discuss challenges and future directions in the context of global tomographic inversions.

  4. Regional-Scale Differential Time Tomography Methods: Development and Application to the Sichuan, China, Dataset

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Thurber, C.; Wang, W.; Roecker, S. W.

    2008-12-01

    We extended our recent development of double-difference seismic tomography [Zhang and Thurber, BSSA, 2003] to the use of station-pair residual differences in addition to event-pair residual differences. Tomography using station- pair residual differences is somewhat akin to teleseismic tomography but with the sources contained within the model region. Synthetic tests show that the inversion using both event- and station-pair residual differences has advantages in terms of more accurately recovering higher-resolution structure in both the source and receiver regions. We used the Spherical-Earth Finite-Difference (SEFD) travel time calculation method in the tomographic system. The basic concept is the extension of a standard Cartesian FD travel time algorithm [Vidale, 1990] to the spherical case by developing a mesh in radius, co-latitude, and longitude, expressing the FD derivatives in a form appropriate to the spherical mesh, and constructing"stencil" to calculate extrapolated travel times. The SEFD travel time calculation method is more advantageous in dealing with heterogeneity and sphericity of the Earth than the simple Earth flattening transformation and the"sphere-in-a-bo" approach [Flanagan et al., 2007]. We applied this method to the Sichuan, China data set for the period of 2001 to 2004. The Vp, Vs and Vp/Vs models show that there is a clear contrast across the Longmenshan Fault, where the 2008 M8 Wenchuan earthquake initiated.

  5. Electrical impedance tomography spectroscopy method for characterising particles in solid-liquid phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Yanlin; Wang, Mi; Yao, Jun

    2014-04-11

    Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases systemmore » involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal particles based on EIS measurement using a sensor of 8 electrodes are reported. Results have demonstrated the potential as well as revealed the challenge in the use of EIS and EITS for characterisation of particle in suspension.« less

  6. Estimating crustal heterogeneity from double-difference tomography

    USGS Publications Warehouse

    Got, J.-L.; Monteiller, V.; Virieux, J.; Okubo, P.

    2006-01-01

    Seismic velocity parameters in limited, but heterogeneous volumes can be inferred using a double-difference tomographic algorithm, but to obtain meaningful results accuracy must be maintained at every step of the computation. MONTEILLER et al. (2005) have devised a double-difference tomographic algorithm that takes full advantage of the accuracy of cross-spectral time-delays of large correlated event sets. This algorithm performs an accurate computation of theoretical travel-time delays in heterogeneous media and applies a suitable inversion scheme based on optimization theory. When applied to Kilauea Volcano, in Hawaii, the double-difference tomography approach shows significant and coherent changes to the velocity model in the well-resolved volumes beneath the Kilauea caldera and the upper east rift. In this paper, we first compare the results obtained using MONTEILLER et al.'s algorithm with those obtained using the classic travel-time tomographic approach. Then, we evaluated the effect of using data series of different accuracies, such as handpicked arrival-time differences ("picking differences"), on the results produced by double-difference tomographic algorithms. We show that picking differences have a non-Gaussian probability density function (pdf). Using a hyperbolic secant pdf instead of a Gaussian pdf allows improvement of the double-difference tomographic result when using picking difference data. We completed our study by investigating the use of spatially discontinuous time-delay data. ?? Birkha??user Verlag, Basel, 2006.

  7. Microseismic Velocity Imaging of the Fracturing Zone

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Chen, Y.

    2015-12-01

    Hydraulic fracturing of low permeability reservoirs can induce microseismic events during fracture development. For this reason, microseismic monitoring using sensors on surface or in borehole have been widely used to delineate fracture spatial distribution and to understand fracturing mechanisms. It is often the case that the stimulated reservoir volume (SRV) is determined solely based on microseismic locations. However, it is known that for some fracture development stage, long period long duration events, instead of microseismic events may be associated. In addition, because microseismic events are essentially weak and there exist different sources of noise during monitoring, some microseismic events could not be detected and thus located. Therefore the estimation of the SRV is biased if it is solely determined by microseismic locations. With the existence of fluids and fractures, the seismic velocity of reservoir layers will be decreased. Based on this fact, we have developed a near real time seismic velocity tomography method to characterize velocity changes associated with fracturing process. The method is based on double-difference seismic tomography algorithm to image the fracturing zone where microseismic events occur by using differential arrival times from microseismic event pairs. To take into account varying data distribution for different fracking stages, the method solves the velocity model in the wavelet domain so that different scales of model features can be obtained according to different data distribution. We have applied this real time tomography method to both acoustic emission data from lab experiment and microseismic data from a downhole microseismic monitoring project for shale gas hydraulic fracturing treatment. The tomography results from lab data clearly show the velocity changes associated with different rock fracturing stages. For the field data application, it shows that microseismic events are located in low velocity anomalies. By combining low velocity anomalies with microseismic events, we should better estimate the SRV.

  8. Combined optical coherence tomography and hyper-spectral imaging using a double clad fiber coupler

    NASA Astrophysics Data System (ADS)

    Guay-Lord, Robin; Lurie, Kristen L.; Attendu, Xavier; Mageau, Lucas; Godbout, Nicolas; Ellerbee Bowden, Audrey K.; Strupler, Mathias; Boudoux, Caroline

    2016-03-01

    This proceedings shows the combination of Optical Coherence Tomography (OCT) and Hyper-Spectral Imaging (HSI) using a double-clad optical fiber. The single mode core of the fiber is used to transmit OCT signals, while the cladding, with its large collection area, provides an efficient way to capture the reflectance spectrum of the sample. The combination of both methods enables three-dimensional acquisition of sample morphology with OCT, enhanced by the molecular information contained in its hyper-spectral image. We believe that the combination of these techniques could result in endoscopes with enhanced tissue identification capability.

  9. Precisely relocated seismicity using 3-D seismic velocity model by double-difference tomography method and orogenic processes in central and southern Taiwan

    NASA Astrophysics Data System (ADS)

    Nagai, S.; Wu, Y.; Suppe, J.; Hirata, N.

    2009-12-01

    The island of Taiwan is located in the site of ongoing arc-continent collision zone between the Philippine Sea Plate and the Eurasian Plate. Numerous geophysical and geological studies are done in and around Taiwan to develop various models to explain the tectonic processes in the Taiwan region. The active and young tectonics and the associated high seismicity in Taiwan provide us with unique opportunity to explore and understand the processes in the region related to the arc-continent collision. Nagai et al. [2009] imaged eastward dipping alternate high- and low-velocity bodies at depths of 5 to 25 km from the western side of the Central Mountain Range to the eastern part of Taiwan, by double-difference tomography [Zhang and Thurber, 2003] using three temporary seismic networks with the Central Weather Bureau Seismic Network(CWBSN). These three temporary networks are the aftershock observation after the 1999 Chi-Chi Taiwan earthquake and two dense linear array observations; one is across central Taiwan in 2001, another is across southern Taiwan in 2005, respectively. We proposed a new orogenic model, ’Upper Crustal Stacking Model’ inferred from our tomographic images. To understand the detailed seismic structure more, we carry on relocating earthquakes more precisely in central and southern Taiwan, using three-dimensional velocity model [Nagai et al., 2009] and P- and S-wave arrival times both from the CWBSN and three temporary networks. We use the double-difference tomography method to improve relative and absolute location accuracy simultaneously. The relocated seismicity is concentrated and limited along the parts of boundaries between low- and high-velocity bodies. Especially, earthquakes occurred beneath the Eastern Central Range, triggered by 1999 Chi-Chi earthquake, delineate subsurface structural boundaries, compared with profiles of estimated seismic velocity. The relocated catalog and 3-D seismic velocity model give us some constraints to reconstruct the orogenic model in Taiwan. We show these relocated seismicity with P- and S-wave velocity profiles, with focal mechanisms [e.g. Wu et al., 2008] and spatio-temporal variation, in central and southern Taiwan and discuss tectonic processes in Taiwan.

  10. High Resolution Hypocenter Relocation for Events in Central Java, Indonesia using Double-Difference Technique

    NASA Astrophysics Data System (ADS)

    Sahara, D. P.; Widiyantoro, S.; Nugraha, A. D.; Sule, R.; Luehr, B. G.

    2010-12-01

    Seismic and volcanic activities in Central Java are highly related to the subduction of the Indo-Australian plate. In the MERapi AMphibious Experiments (MERAMEX), a network consisting of 169 seismographic stations was installed onshore and offshore in central Java and recorded 282 events during the operation. In this study, we present the results of relative hypocenters relocation by using Double Difference (DD) method to image the subduction beneath the volcanic chain in central Java. The DD method is an iterative procedure using Least Square optimization to determine high-resolution hypocenter locations over large distances. This relocation method uses absolute travel-time measurements and/or cross-correlation of P- and S-wave differential travel-time measurements. The preliminary results of our study showed that the algorithm could collapse the diffused event locations obtained from previous study into a sharp image of seismicity structure and reduce the residual travel time errors significantly (7 - 60%). As a result, narrow regions of a double seismic zone which correlated with the subducting slab can be determined more accurately. The dip angle of the slab increases gradually from almost horizontal beneath offshore to very steep (65-80 degrees) beneath the northern part of central Java. The aseismic gap at depths of 140 km - 185 km is also depicted clearly. The next step of the ongoing research is to provide detailed quantitative constraints on the structures of the mantle wedge and crust beneath central Java and to show the ascending paths of fluids and partially molten materials below the volcanic arc by applying Double-Difference Tomography method (TomoDD).

  11. Structure resolution by electron diffraction tomography of the complex layered iron-rich Fe-2234-type Sr{sub 5}Fe{sub 6}O{sub 15.4}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lepoittevin, Christophe, E-mail: christophe.lepoittevin@neel.cnrs.fr

    2016-10-15

    The crystal structure of the strontium ferrite Sr{sub 5}Fe{sub 6}O{sub 15.4}, was solved by direct methods on electron diffraction tomography data acquired on a transmission electron microscope. The refined cell parameters are a=27.4047(3) Å, b=5.48590(7) Å and c=42.7442(4) Å in Fm2m symmetry. Its structure is built up from the intergrowth sequence between a quadruple perovskite-type layer with a complex rock-salt (RS)-type block. In the latter iron atoms are found in two different environments : tetragonal pyramid and tetrahedron. The structural model was refined by Rietveld method based on the powder X-ray diffraction pattern. - Highlights: • Complex structure of Sr{submore » 5}Fe{sub 6}O{sub 15.4} solved by electron diffraction tomography. • Observed Fourier maps allow determining missing oxygen atoms in the structure. • Structural model refined from powder X-ray diffraction data. • Intergrowth between quadruple perovskite layer with double rock-salt-type layer.« less

  12. Retinal optical coherence tomography image enhancement via shrinkage denoising using double-density dual-tree complex wavelet transform

    PubMed Central

    Mayer, Markus A.; Boretsky, Adam R.; van Kuijk, Frederik J.; Motamedi, Massoud

    2012-01-01

    Abstract. Image enhancement of retinal structures, in optical coherence tomography (OCT) scans through denoising, has the potential to aid in the diagnosis of several eye diseases. In this paper, a locally adaptive denoising algorithm using double-density dual-tree complex wavelet transform, a combination of the double-density wavelet transform and the dual-tree complex wavelet transform, is applied to reduce speckle noise in OCT images of the retina. The algorithm overcomes the limitations of commonly used multiple frame averaging technique, namely the limited number of frames that can be recorded due to eye movements, by providing a comparable image quality in significantly less acquisition time equal to an order of magnitude less time compared to the averaging method. In addition, improvements of image quality metrics and 5 dB increase in the signal-to-noise ratio are attained. PMID:23117804

  13. Retinal optical coherence tomography image enhancement via shrinkage denoising using double-density dual-tree complex wavelet transform.

    PubMed

    Chitchian, Shahab; Mayer, Markus A; Boretsky, Adam R; van Kuijk, Frederik J; Motamedi, Massoud

    2012-11-01

    ABSTRACT. Image enhancement of retinal structures, in optical coherence tomography (OCT) scans through denoising, has the potential to aid in the diagnosis of several eye diseases. In this paper, a locally adaptive denoising algorithm using double-density dual-tree complex wavelet transform, a combination of the double-density wavelet transform and the dual-tree complex wavelet transform, is applied to reduce speckle noise in OCT images of the retina. The algorithm overcomes the limitations of commonly used multiple frame averaging technique, namely the limited number of frames that can be recorded due to eye movements, by providing a comparable image quality in significantly less acquisition time equal to an order of magnitude less time compared to the averaging method. In addition, improvements of image quality metrics and 5 dB increase in the signal-to-noise ratio are attained.

  14. Seismic imaging of the oil and geothermal reservoirs using the induced seismicity

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Toksoz, M. N.; Fehler, M.

    2011-12-01

    It is known that microseismicity can be induced in the oil field due to the stress change caused by oil/gas production. Similarly, injection of high-pressure fluids into the reservoir can also induce microseismicity. Due to the proximity of induced seismicity to the reservoir, in some cases, it may be advantageous to use induced seismicity to image the reservoir. The seismic stations for monitoring the induced seismicity are usually sparse. Conventional travel time tomography using travel times from seismic events to stations may not be applicable because of poor ray coverage outside the source region. In comparison, the double-difference tomography method of Zhang and Thurber (2003) that uses the differential travel times is able to image the reservoir by avoiding determining the velocity structure outside the source region. In this study, we present two case studies of applying double-difference tomography to induced seismicity monitored by borehole stations. In the case of an oil field in Oman, five closely spaced monitoring wells are used to monitor microseismicity induced by gas production. In each well, multiple seismic sensors are positioned from depths 750 m - 1250 m and about 2000 events are selected for tomography. Reservoir imaging shows encouraging results in identifying structures and velocity changes within reservoir layers. Clear velocity contrast was seen across the major northeast-southwest faults. Low Vp, low Vs and low Vp/Vs anomalies are mainly associated with the gas production layer. For the case of the Soultz Enhanced Geothermal System at Soultz-sous-Forets, France, we used travel time data from the September and October 1993 hydraulic stimulations, where only four borehole stations are available. The results showed that the S-wave velocity structure correlated well with seismicity and showed low velocity zones at depths between 2900 and 3300 meters, where fluid was believed to have infiltrated the reservoir. We also attempt time-lapse tomography to determine velocity changes at different stages of stimulation. The preliminary results show that the velocity increases outside the reservoir and decreases in the seismicity region.

  15. Time-resolved seismic tomography at the EGS geothermal reservoir of Soultz-Sous-Forêts (France) during hydraulic stimulations. A comparison between different injection tests

    NASA Astrophysics Data System (ADS)

    Dorbath, C.; Calo, M.; Cornet, F.; Frogneux, M.

    2011-12-01

    One major goal of monitoring seismicity accompanying hydraulic fracturing of a reservoir is to recover the seismic velocity field in and around the geothermal site. Several studies have shown that the 4D (time dependent) seismic tomographies are very useful to illustrate and study the temporal variation of the seismic velocities conditioned by injected fluids. However, only an appropriate separation of the data in subsets and a reliable tomographic method allow studying representative variations of the seismic velocities during and after the injection periods. We present here new 4D seismic tomographies performed using datasets regarding some stimulation tests performed at the Enhanced Geothermal System (EGS) site of Soultz-sous-Forêts (Alsace, France). The data used were recorded during the stimulation tests occurred in 2000, 2003 and 2004 that involved the wells GPK2, GPK3 and GPK4. For each set of events, the subsetting of the data was performed by taking into account the injection parameters of the stimulation tests (namely the injected flow rate and the wellhead pressure). The velocity models have been obtained using the Double-Difference tomographic method (Zhang and Thurber 2003) and further improved with the post-processing WAM technique (Calo' et al., 2009, 2011). This technique resulted very powerful because combines high resolution and reliablity of the seismic velocity fields calculated even with small datasets. In this work we show the complete sequence of the time-lapse tomographies and their variations in time and between different stimulation tests.

  16. [A simulation study with finite element model on the unequal loss of peripheral vision caused by acceleration].

    PubMed

    Geng, Xiaoqi; Liu, Xiaoyu; Liu, Songyang; Xu, Yan; Zhao, Xianliang; Wang, Jie; Fan, Yubo

    2017-04-01

    An unequal loss of peripheral vision may happen with high sustaining multi-axis acceleration, leading to a great potential flight safety hazard. In the present research, finite element method was used to study the mechanism of unequal loss of peripheral vision. Firstly, a 3D geometric model of skull was developed based on the adult computer tomography (CT) images. The model of double eyes was created by mirroring with the previous right eye model. Then, the double-eye model was matched to the skull model, and fat was filled between eyeballs and skull. Acceleration loads of head-to-foot (G z ), right-to-left (G y ), chest-to-back (G x ) and multi-axis directions were applied to the current model to simulate dynamic response of retina by explicit dynamics solution. The results showed that the relative strain of double eyes was 25.7% under multi-axis acceleration load. Moreover, the strain distributions showed a significant difference among acceleration loaded in different directions. It indicated that a finite element model of double eyes was an effective means to study the mechanism of an unequal loss of peripheral vision at sustaining high multi-axis acceleration.

  17. Simultaneous reconstruction of 3D refractive index, temperature, and intensity distribution of combustion flame by double computed tomography technologies based on spatial phase-shifting method

    NASA Astrophysics Data System (ADS)

    Guo, Zhenyan; Song, Yang; Yuan, Qun; Wulan, Tuya; Chen, Lei

    2017-06-01

    In this paper, a transient multi-parameter three-dimensional (3D) reconstruction method is proposed to diagnose and visualize a combustion flow field. Emission and transmission tomography based on spatial phase-shifted technology are combined to reconstruct, simultaneously, the various physical parameter distributions of a propane flame. Two cameras triggered by the internal trigger mode capture the projection information of the emission and moiré tomography, respectively. A two-step spatial phase-shifting method is applied to extract the phase distribution in the moiré fringes. By using the filtered back-projection algorithm, we reconstruct the 3D refractive-index distribution of the combustion flow field. Finally, the 3D temperature distribution of the flame is obtained from the refractive index distribution using the Gladstone-Dale equation. Meanwhile, the 3D intensity distribution is reconstructed based on the radiation projections from the emission tomography. Therefore, the structure and edge information of the propane flame are well visualized.

  18. Application of double-layered skin phantoms for optical flow imaging during laser tattoo treatments

    NASA Astrophysics Data System (ADS)

    Lee, Byeong-il; Song, Woosub; Kim, Hyejin; Kang, Hyun Wook

    2016-05-01

    The feasible application of double-layered skin phantoms was evaluated to identify artificial blood flow with a Doppler optical coherence tomography (DOCT) system for laser tattoo treatments. Polydimethylsiloxane (PDMS) was used to fabricate the artificial phantoms with flow channels embedded. A double-integrating sphere system with an inverse adding-doubling method quantified both the absorption and the reduced scattering coefficients for epidermis and dermis phantoms. Both OCT and caliper measurements confirmed the double-layered phantom structure (epidermis = 136 ± 17 µm vs. dermis = 3.0 ± 0.1 mm). The DOCT method demonstrated that high flow rates were associated with high image contrast, visualizing the position and the shape of the flow channel. Application of the channel-embedded skin phantoms in conjunction with DOCT can be a reliable technique to assess dynamic variations in the blood flow during and after laser tattoo treatments.

  19. Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.

    PubMed

    Helaly, Hany A; El-Hifnawy, Mohammad A M; Shaheen, Mohamed Shafik; Abou El-Kheir, Amr F

    2016-01-01

    To evaluate the accuracy of corneal power measurements for intraocular lens (IOL) power calculation after myopic laser in situ keratomileusis (LASIK). The study evaluated 45 eyes with a history of myopic LASIK. Corneal power was measured using manual keratometry, automated keratometry, optical biometry, and Scheimflug tomography. Different hypothetical IOL power calculation formulas were performed for each case. The steepest mean K value was measured with manual keratometry (37.48 ± 2.86 D) followed by automated keratometry (37.31 ± 2.83 D) then optical biometry (37.06 ± 2.98 D) followed by Scheimflug tomography (36.55 ± 3.08). None of the K values generated by Scheimflug tomography were steeper than the measurements from the other 3 instruments. Using equivalent K reading (EKR) 4 mm with the Double-K SRK/T formula, the refractive outcome generated 97.8% of cases within ± 2 D, 80.0% of cases within ± 1 D, and 42.2% of cases within ± 0.5 D. The best combination of formulas was "Shammas-PL + Double-K SRK/T formula using EKR 4 mm." Scheimflug tomography imaging using the Holladay EKR 4 mm improved the accuracy of IOL power calculation in post-LASIK eyes. The best option is a combination of formulas. We recommended the use the combined "Shammas-PL ± Double-K SRK/T formula using EKR 4 mm"h for optical outcomes.

  20. Joint Inversion of Body-Wave Arrival Times and Surface-Wave Dispersion Data in the Wavelet Domain Constrained by Sparsity Regularization

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Fang, H.; Yao, H.; Maceira, M.; van der Hilst, R. D.

    2014-12-01

    Recently, Zhang et al. (2014, Pure and Appiled Geophysics) have developed a joint inversion code incorporating body-wave arrival times and surface-wave dispersion data. The joint inversion code was based on the regional-scale version of the double-difference tomography algorithm tomoDD. The surface-wave inversion part uses the propagator matrix solver in the algorithm DISPER80 (Saito, 1988) for forward calculation of dispersion curves from layered velocity models and the related sensitivities. The application of the joint inversion code to the SAFOD site in central California shows that the fault structure is better imaged in the new model, which is able to fit both the body-wave and surface-wave observations adequately. Here we present a new joint inversion method that solves the model in the wavelet domain constrained by sparsity regularization. Compared to the previous method, it has the following advantages: (1) The method is both data- and model-adaptive. For the velocity model, it can be represented by different wavelet coefficients at different scales, which are generally sparse. By constraining the model wavelet coefficients to be sparse, the inversion in the wavelet domain can inherently adapt to the data distribution so that the model has higher spatial resolution in the good data coverage zone. Fang and Zhang (2014, Geophysical Journal International) have showed the superior performance of the wavelet-based double-difference seismic tomography method compared to the conventional method. (2) For the surface wave inversion, the joint inversion code takes advantage of the recent development of direct inversion of surface wave dispersion data for 3-D variations of shear wave velocity without the intermediate step of phase or group velocity maps (Fang et al., 2014, Geophysical Journal International). A fast marching method is used to compute, at each period, surface wave traveltimes and ray paths between sources and receivers. We will test the new joint inversion code at the SAFOD site to compare its performance over the previous code. We will also select another fault zone such as the San Jacinto Fault Zone to better image its structure.

  1. Preliminary Analysis of Double Shell Tomography Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pascucci, V

    2009-01-16

    In this project we have collaborated with LLNL scientists Dr. Peer-Timo Bremer while performing our research work on algorithmic solutions for geometric processing, image segmentation and data streaming. The main deliverable has been a 3D viewer for high-resolution imaging data with particular focus on the presentation of orthogonal slices of the double shell tomography dataset. Basic probing capabilities allow querying single voxels in the data to study in detail the information presented to the user and compensate for the intrinsic filtering and imprecision due to visualization based on colormaps. On the algorithmic front we have studied the possibility of usingmore » of non-local means filtering algorithm to achieve noise removal from tomography data. In particular we have developed a prototype that implements an accelerated version of the algorithm that may be able to take advantage of the multi-resolution sub-sampling of the ViSUS format. We have achieved promising results. Future plans include the full integration of the non-local means algorithm in the ViSUS frameworks and testing if the accelerated method will scale properly from 2D images to 3D tomography data.« less

  2. Azimuthally Anisotropic Global Adjoint Tomography

    NASA Astrophysics Data System (ADS)

    Bozdag, E.; Orsvuran, R.; Lefebvre, M. P.; Lei, W.; Peter, D. B.; Ruan, Y.; Smith, J. A.; Komatitsch, D.; Tromp, J.

    2017-12-01

    Earth's upper mantle shows significant evidence of anisotropy as a result of its composition and deformation. After the first-generation global adjoint tomography model, GLAD-M15 (Bozdag et al. 2016), which has transverse isotropy confined to upper mantle, we continue our iterations including surface-wave azimuthal anisotropy with an emphasis on the upper mantle. We are focusing on four elastic parameters that surface waves are known to be most sensitive to, namely, vertically and horizontally polarized shear waves and the density-normalised anisotropic parameters Gc' & Gs'. As part of the current anisotropic inversions, which will lead to our "second-generation" global adjoint tomography model, we have started exploring new misfits based on a double-difference approach (Yuan et al. 2016). We define our misfit function in terms of double-difference multitaper measurements, where each waveform is normalized by its number of pairs in the period ranges 45-100 s & 90-250 s. New measurements result in better balanced gradients while extracting more information underneath clusters of stations, such as USArray. Our initial results reveals multi-scale anisotorpic signals depending on ray (kernel) coverage close to continental-scale resolution in areas with dense coverage, consistent with previous studies.

  3. Single photon emission computed tomography-guided Cerenkov luminescence tomography

    NASA Astrophysics Data System (ADS)

    Hu, Zhenhua; Chen, Xueli; Liang, Jimin; Qu, Xiaochao; Chen, Duofang; Yang, Weidong; Wang, Jing; Cao, Feng; Tian, Jie

    2012-07-01

    Cerenkov luminescence tomography (CLT) has become a valuable tool for preclinical imaging because of its ability of reconstructing the three-dimensional distribution and activity of the radiopharmaceuticals. However, it is still far from a mature technology and suffers from relatively low spatial resolution due to the ill-posed inverse problem for the tomographic reconstruction. In this paper, we presented a single photon emission computed tomography (SPECT)-guided reconstruction method for CLT, in which a priori information of the permissible source region (PSR) from SPECT imaging results was incorporated to effectively reduce the ill-posedness of the inverse reconstruction problem. The performance of the method was first validated with the experimental reconstruction of an adult athymic nude mouse implanted with a Na131I radioactive source and an adult athymic nude mouse received an intravenous tail injection of Na131I. A tissue-mimic phantom based experiment was then conducted to illustrate the ability of the proposed method in resolving double sources. Compared with the traditional PSR strategy in which the PSR was determined by the surface flux distribution, the proposed method obtained much more accurate and encouraging localization and resolution results. Preliminary results showed that the proposed SPECT-guided reconstruction method was insensitive to the regularization methods and ignored the heterogeneity of tissues which can avoid the segmentation procedure of the organs.

  4. Detection of bladder metabolic artifacts in (18)F-FDG PET imaging.

    PubMed

    Roman-Jimenez, Geoffrey; Crevoisier, Renaud De; Leseur, Julie; Devillers, Anne; Ospina, Juan David; Simon, Antoine; Terve, Pierre; Acosta, Oscar

    2016-04-01

    Positron emission tomography using (18)F-fluorodeoxyglucose ((18)F-FDG-PET) is a widely used imaging modality in oncology. It enables significant functional information to be included in analyses of anatomical data provided by other image modalities. Although PET offers high sensitivity in detecting suspected malignant metabolism, (18)F-FDG uptake is not tumor-specific and can also be fixed in surrounding healthy tissue, which may consequently be mistaken as cancerous. PET analyses may be particularly hampered in pelvic-located cancers by the bladder׳s physiological uptake potentially obliterating the tumor uptake. In this paper, we propose a novel method for detecting (18)F-FDG bladder artifacts based on a multi-feature double-step classification approach. Using two manually defined seeds (tumor and bladder), the method consists of a semi-automated double-step clustering strategy that simultaneously takes into consideration standard uptake values (SUV) on PET, Hounsfield values on computed tomography (CT), and the distance to the seeds. This method was performed on 52 PET/CT images from patients treated for locally advanced cervical cancer. Manual delineations of the bladder on CT images were used in order to evaluate bladder uptake detection capability. Tumor preservation was evaluated using a manual segmentation of the tumor, with a threshold of 42% of the maximal uptake within the tumor. Robustness was assessed by randomly selecting different initial seeds. The classification averages were 0.94±0.09 for sensitivity, 0.98±0.01 specificity, and 0.98±0.01 accuracy. These results suggest that this method is able to detect most (18)F-FDG bladder metabolism artifacts while preserving tumor uptake, and could thus be used as a pre-processing step for further non-parasitized PET analyses. Copyright © 2016. Published by Elsevier Ltd.

  5. Frequency doubling technique perimetry and spectral domain optical coherence tomography in patients with early glaucoma

    PubMed Central

    Horn, F K; Mardin, C Y; Bendschneider, D; Jünemann, A G; Adler, W; Tornow, R P

    2011-01-01

    Purpose To assess the combined diagnostic power of frequency-doubling technique (FDT)-perimetry and retinal nerve fibre layer (RNFL) thickness measurements with spectral domain optical coherence tomography (SDOCT). Methods The study included 330 experienced participants in five age-related groups: 77 ‘preperimetric' open-angle glaucoma (OAG) patients, 52 ‘early' OAG, 50 ‘moderate' OAG, 54 ocular hypertensivepatients, and 97 healthy subjects. For glaucoma assessment in all subjects conventional perimetry, evaluation of fundus photographs, FDT-perimetry and RNFL thickness measurement with SDOCT was done. Glaucomatous visual field defects were classified using the Glaucoma Staging System. FDT evaluation used a published method with casewise calculation of an ‘FDT-score', including all missed localized probability levels. SDOCT evaluation used mean RNFL thickness and a new individual SDOCT-score considering normal confidence limits in 32 sectors of a peripapillary circular scan. To examine the joined value of both methods a combined score was introduced. Significance of the difference between Receiver-operating-characteristic (ROC) curves was calculated for a specificity of 96%. Results Sensitivity in the preperimetric glaucoma group was 44% for SDOCT-score, 25% for FDT-score, and 44% for combined score, in the early glaucoma group 83, 81, and 89%, respectively, and in the moderate glaucoma group 94, 94, and 98%, respectively, all at a specificity of 96%. ROC performance of the newly developed combined score is significantly above single ROC curves of FDT-score in preperimetric and early OAG and above RNFL thickness in moderate OAG. Conclusion Combination of function and morphology by using the FDT-score and the SDOCT-score performs equal or even better than each single method alone. PMID:21102494

  6. Double-difference tomography velocity structure in Northern Oklahoma: Evidence for reduced basement velocity in the Nemaha Uplift

    NASA Astrophysics Data System (ADS)

    Stevens, N. T.; Keranen, K. M.; Lambert, C.

    2016-12-01

    Induced seismicity in northern Oklahoma presents risk for infrastructure, but also an opportunity to gain new insights to earthquake processes [Petersen et al., 2016]. Here we present a double-difference tomographic study using TomoDD [Zhang and Thurber, 2003] in northern Oklahoma utilizing records from a dense broadband network over a 1-year period, constituting a catalog of over 10,000 local seismic events. We image a shallow (depth < 4 km) high-velocity structure consistent with the Nemaha uplift [Gay, 2003a], bounded by shallow, lower-velocity regions on either side, likely sedimentary strata at this depth bounding uplifted basement. Velocities within the uplift are lower than expected in subjacent crystalline basement rock (depth > 4 km). We suggest that this low velocity anomaly stems from enhanced fracturing and/or weathering of the basement in the Nemaha uplift in northern Oklahoma. This velocity anomaly is not observed in basement off the shoulders of the structure, particularly to the southeast of the Nemaha bounding fault. Enhanced fracturing, and related increases to permeability, would ease pressure migration from injection wells linked to increased seismicity in the region, and may explain the relative absence of seismicity coincident with this structure compared to it periphery. References Gay, S. Parker, J. (2003), The Nemaha Trend-A System of Compressional Thrust-Fold, Strike-Slilp Structural Features in Kansas and Oklahoma, Part 1, Shale Shak., 9-49. Petersen, M. D., C. S. Mueller, M. P. Moschetti, S. M. Hoover, A. L. Llenos, W. L. Ellsworth, A. J. Michael, J. L. Rubinstein, A. F. McGarr, and K. S. Rukstales (2016), 2016 One-Year Seismic Hazard Forecast for the Central and Eastern United States from Induced and Natural Earthquakes, Open-File Rep., doi:10.3133/OFR20161035. Zhang, H., and C. H. Thurber (2003), Double-difference tomography: The method and its application to the Hayward Fault, California, Bull. Seismol. Soc. Am., 93(5), 1875-1889, doi:10.1785/0120020190.

  7. Wet refractivity tomography with an improved Kalman-Filter method

    NASA Astrophysics Data System (ADS)

    Cao, Yunchang; Chen, Yongqi; Li, Pingwha

    2006-10-01

    An improved retrieval method, which uses the solution with a Gaussian constraint as the initial state variables for the Kalman Filtering (KF) method, was developed to retrieve the wet refractivity profiles from slant wet delays (SWD) extracted by the double-differenced (DD) GPS method. The accuracy of the GPS-derived SWDs is also tested in this study against the measurements of a water vapor radiometer (WVR) and a weather model. It is concluded that the GPS-derived SWDs have similar accuracy to those measured with WVR and are much higher in quality than those derived from the weather model used. The developed method is used to retrieve the 3D wet refractivity distribution in the Hong Kong region. The retrieved profiles agree well with the radiosonde observations, with a difference of about 4 mm km-1 in the low levels. The accurate profiles obtained with this method are applicable in a number of meteorological applications.

  8. Frequency doubling technique perimetry and spectral domain optical coherence tomography in patients with early glaucoma.

    PubMed

    Horn, F K; Mardin, C Y; Bendschneider, D; Jünemann, A G; Adler, W; Tornow, R P

    2011-01-01

    To assess the combined diagnostic power of frequency-doubling technique (FDT)-perimetry and retinal nerve fibre layer (RNFL) thickness measurements with spectral domain optical coherence tomography (SDOCT). The study included 330 experienced participants in five age-related groups: 77 'preperimetric' open-angle glaucoma (OAG) patients, 52 'early' OAG, 50 'moderate' OAG, 54 ocular hypertensive patients, and 97 healthy subjects. For glaucoma assessment in all subjects conventional perimetry, evaluation of fundus photographs, FDT-perimetry and RNFL thickness measurement with SDOCT was done. Glaucomatous visual field defects were classified using the Glaucoma Staging System. FDT evaluation used a published method with casewise calculation of an 'FDT-score', including all missed localized probability levels. SDOCT evaluation used mean RNFL thickness and a new individual SDOCT-score considering normal confidence limits in 32 sectors of a peripapillary circular scan. To examine the joined value of both methods a combined score was introduced. Significance of the difference between Receiver-operating-characteristic (ROC) curves was calculated for a specificity of 96%. Sensitivity in the preperimetric glaucoma group was 44% for SDOCT-score, 25% for FDT-score, and 44% for combined score, in the early glaucoma group 83, 81, and 89%, respectively, and in the moderate glaucoma group 94, 94, and 98%, respectively, all at a specificity of 96%. ROC performance of the newly developed combined score is significantly above single ROC curves of FDT-score in preperimetric and early OAG and above RNFL thickness in moderate OAG. Combination of function and morphology by using the FDT-score and the SDOCT-score performs equal or even better than each single method alone.

  9. Drug delivery monitoring by photoacoustic tomography with an ICG encapsulated double emulsion

    NASA Astrophysics Data System (ADS)

    Wang, Xueding; Rajian, Justin R.; Fabiilli, Mario L.; Fowlkes, J. Brian; Carson, Paul L.

    2012-02-01

    We successfully encapsulated ICG in an ultrasound-triggerable perfluorocarbon double emulsion that prevents ICG from binding with plasma proteins. Photoacoustic spectral measurements on point target as well as 2-D photoacoustic images of blood vessels revealed that the photoacoustic spectrum changes significantly in blood when the ICG-loaded emulsion undergoes acoustic droplet vaporization (ADV), which is the conversion of liquid droplets into gas bubbles using ultrasound. Other than providing a new photoacoustic contrast agent, the ICG encapsulated double emulsion, when imaged with photoacoustic tomography, could facilitate spatial and quantitative monitoring of ultrasound initiated drug delivery.

  10. Determination of the 4D-Tropospheric Water Vapor Distribution by GPS for the Assimilation into Numerical Weather Prediction Models

    NASA Astrophysics Data System (ADS)

    Perler, D.; Geiger, A.; Rothacher, M.

    2011-12-01

    Water vapor is involved in many atmospheric processes and is therefore a crucial quantity in numerical weather prediction (NWP). Recent flood events in Switzerland have pointed out several deficiencies in planning and prediction methods used for flood risk mitigation. Investigations have shown that one of the limiting factors to forecast such events with NWP models is the insufficient knowledge of the water vapor distribution in the atmosphere. Global Navigation Satellite System (GNSS) ground-based tomography is a technique to monitor the 4D distribution of water vapor in the troposphere and has the potential to considerably improve the initial water vapor field used in NWP. We developed a GNSS tomography software called AWATOS-2 which is based on the Kalman filter technique and provides different parameterizations of the tropospheric wet refractivity field (Perler et al., 2010; Perler et al., 2011). The software can be used for the assimilation of different observations such as GNSS zero-differences, GNSS double-differences and any kind of point observations (e.g. balloons, aircrafts). In this talk, we present the results of a long-term study where GPS double-difference delays have been processed. The tomographic solutions have been investigated in view of their assimilation into local NWP models. The data set comprises observations from 46 GPS stations collected during 1 year. The core area of the investigation is located in Central Europe. We analyzed the performance of different voxel parameterizations used in the tomographic reconstruction of the troposphere and developed a new bias correction model which minimizes systematic differences. The correction model reduces the root-mean-square error (RMSE) with respected to the NWP model from 4.6 ppm to 3.0 ppm. After bias correction, high-elevation stations still show high RMSEs. In the presentation, we will discuss the treatment of such stations in terms of assimilation into NWP models and will show how sophisticated voxel parameterizations improve the accuracy. Perler, D.; Hurter, F.; Brockmann, E.; Leuenberger, D.; Ruffieux, D.; Geiger, A. and Rothacher, M. (2010). In Proceedings of the 7th Management Committee (MC7) and Working Group (WG) Meeting, Colone (Germany), 8 pp. Perler, D.; Geiger, A. and Hurter, F. (2011). 4D GPS water vapor tomography: new parameterized approaches. J. Geodesy 85(8), pp. 539-550, DOI 10.1007/s00190-011-0454-2.

  11. Color sensitive silicon photomultiplers with micro-cell level encoding for DOI PET detectors

    NASA Astrophysics Data System (ADS)

    Shimazoe, Kenji; Koyama, Akihiro; Takahashi, Hiroyuki; Ganka, Thomas; Iskra, Peter; Marquez Seco, Alicia; Schneider, Florian; Wiest, Florian

    2017-11-01

    There have been many studies on Depth Of Interaction (DOI) identification for high resolution Positron Emission Tomography (PET) systems, including those on phoswich detectors, double-sided readout, light sharing methods, and wavelength discrimination. The wavelength discrimination method utilizes the difference in wavelength of stacked scintillators and requires a color sensitive photodetector. Here, a new silicon photomultiplier (SiPM) coupled to a color filter (colorSiPM) was designed and fabricated for DOI detection. The fabricated colorSiPM has two anode readouts that are sensitive to blue and green color. The colorSiPM's response and DOI identification capability for stacked GAGG and LYSO crystals are characterized. The fabricated colorSiPM is sensitive enough to detect a peak of 662 keV from a 137 Cs source.

  12. Iterative methods for tomography problems: implementation to a cross-well tomography problem

    NASA Astrophysics Data System (ADS)

    Karadeniz, M. F.; Weber, G. W.

    2018-01-01

    The velocity distribution between two boreholes is reconstructed by cross-well tomography, which is commonly used in geology. In this paper, iterative methods, Kaczmarz’s algorithm, algebraic reconstruction technique (ART), and simultaneous iterative reconstruction technique (SIRT), are implemented to a specific cross-well tomography problem. Convergence to the solution of these methods and their CPU time for the cross-well tomography problem are compared. Furthermore, these three methods for this problem are compared for different tolerance values.

  13. Variable pixel size ionospheric tomography

    NASA Astrophysics Data System (ADS)

    Zheng, Dunyong; Zheng, Hongwei; Wang, Yanjun; Nie, Wenfeng; Li, Chaokui; Ao, Minsi; Hu, Wusheng; Zhou, Wei

    2017-06-01

    A novel ionospheric tomography technique based on variable pixel size was developed for the tomographic reconstruction of the ionospheric electron density (IED) distribution. In variable pixel size computerized ionospheric tomography (VPSCIT) model, the IED distribution is parameterized by a decomposition of the lower and upper ionosphere with different pixel sizes. Thus, the lower and upper IED distribution may be very differently determined by the available data. The variable pixel size ionospheric tomography and constant pixel size tomography are similar in most other aspects. There are some differences between two kinds of models with constant and variable pixel size respectively, one is that the segments of GPS signal pay should be assigned to the different kinds of pixel in inversion; the other is smoothness constraint factor need to make the appropriate modified where the pixel change in size. For a real dataset, the variable pixel size method distinguishes different electron density distribution zones better than the constant pixel size method. Furthermore, it can be non-chided that when the effort is spent to identify the regions in a model with best data coverage. The variable pixel size method can not only greatly improve the efficiency of inversion, but also produce IED images with high fidelity which are the same as a used uniform pixel size method. In addition, variable pixel size tomography can reduce the underdetermined problem in an ill-posed inverse problem when the data coverage is irregular or less by adjusting quantitative proportion of pixels with different sizes. In comparison with constant pixel size tomography models, the variable pixel size ionospheric tomography technique achieved relatively good results in a numerical simulation. A careful validation of the reliability and superiority of variable pixel size ionospheric tomography was performed. Finally, according to the results of the statistical analysis and quantitative comparison, the proposed method offers an improvement of 8% compared with conventional constant pixel size tomography models in the forward modeling.

  14. Ultrahigh-speed ultrahigh-resolution adaptive optics: optical coherence tomography system for in-vivo small animal retinal imaging

    NASA Astrophysics Data System (ADS)

    Jian, Yifan; Xu, Jing; Zawadzki, Robert J.; Sarunic, Marinko V.

    2013-03-01

    Small animal models of human retinal diseases are a critical component of vision research. In this report, we present an ultrahigh-resolution ultrahigh-speed adaptive optics optical coherence tomography (AO-OCT) system for small animal retinal imaging (mouse, fish, etc.). We adapted our imaging system to different types of small animals in accordance with the optical properties of their eyes. Results of AO-OCT images of small animal retinas acquired with AO correction are presented. Cellular structures including nerve fiber bundles, capillary networks and detailed double-cone photoreceptors are visualized.

  15. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    PubMed Central

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration. PMID:24379541

  16. Velocity structures of Geothermal sites: A comparative study between different tomography techniques on the EGS-Soultz-sous-Forêts Site (France)

    NASA Astrophysics Data System (ADS)

    Calo', M. C.; Dorbath, C.

    2009-12-01

    One major goal of monitoring seismicity accompanying hydraulic fracturing of a reservoir is to recover the seismic velocity field in and around the geothermal site. In many cases the seismicity induced by the hydraulic stimulations allows us to roughly describe the velocity anomalies close to the hypocentral location, but only during the time period of the stimulation. Several studies have shown that the 4D (time dependent) seismic tomographies are very useful to illustrate and study the temporal variation of the seismic velocities conditioned by injected fluids. Nevertheless in geothermal fields local earthquake tomography (LET) is often inadequate to study the seismic velocities during the inter-injection periods, due to the lack of seismicity. In July 2000 an injection test that lasted 15 days performed at the Enhanced Geothermal System (EGS) site of Soultz-sous-Forêts (Alsace, France) produced about 7200 micro-earthquakes with Duration Magnitude ranging from -0.9 to 2.5. the earthquakes were located by down hole and surface seismic stations. We present here a comparison between three tomographic studies, 1) the “traditional” seismic tomography of Cuneot et al., 2008, 2) a Double Difference tomography using the TomoDD code of Zhang and Thurber (2003) and, 3) the models obtained by applying the Weighted Average Model method (WAM, Calo’ et al., 2009). the velocity models were obtained using the same dataset recorded during the stimulation. The WAM technique produces a more reliable reconstruction of the structures around and above the cluster of earthquakes, as demonstrated by the distribution of the velocity standard deviations. Although the velocity distributions obtained by the three tomographic approaches are qualitatively similar, the WAM results correlate better with independent data such the fracturing directions measured in the down-holes, the location of the clustered seimsicity) than those of the traditional and DD tomographies. To overcome the limits of LET during the inter-injection periods we plan to perform a seismic noise tomography study. In geothermal sites, the elastic characteristics of the volume at rest, i.e. during the inter-injection periods, are often poorly known.

  17. A new algorithm for three-dimensional joint inversion of body wave and surface wave data and its application to the Southern California plate boundary region

    NASA Astrophysics Data System (ADS)

    Fang, Hongjian; Zhang, Haijiang; Yao, Huajian; Allam, Amir; Zigone, Dimitri; Ben-Zion, Yehuda; Thurber, Clifford; van der Hilst, Robert D.

    2016-05-01

    We introduce a new algorithm for joint inversion of body wave and surface wave data to get better 3-D P wave (Vp) and S wave (Vs) velocity models by taking advantage of the complementary strengths of each data set. Our joint inversion algorithm uses a one-step inversion of surface wave traveltime measurements at different periods for 3-D Vs and Vp models without constructing the intermediate phase or group velocity maps. This allows a more straightforward modeling of surface wave traveltime data with the body wave arrival times. We take into consideration the sensitivity of surface wave data with respect to Vp in addition to its large sensitivity to Vs, which means both models are constrained by two different data types. The method is applied to determine 3-D crustal Vp and Vs models using body wave and Rayleigh wave data in the Southern California plate boundary region, which has previously been studied with both double-difference tomography method using body wave arrival times and ambient noise tomography method with Rayleigh and Love wave group velocity dispersion measurements. Our approach creates self-consistent and unique models with no prominent gaps, with Rayleigh wave data resolving shallow and large-scale features and body wave data constraining relatively deeper structures where their ray coverage is good. The velocity model from the joint inversion is consistent with local geological structures and produces better fits to observed seismic waveforms than the current Southern California Earthquake Center (SCEC) model.

  18. Doppler optical coherence tomography of retinal circulation.

    PubMed

    Tan, Ou; Wang, Yimin; Konduru, Ranjith K; Zhang, Xinbo; Sadda, SriniVas R; Huang, David

    2012-09-18

    Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can be calculated. The standard clinical protocol calls for 3 CDCS scans made with the OCT beam passing through the superonasal edge of the pupil and 3 CDCS scan through the inferonal pupil. This double-angle protocol ensures that acceptable Doppler angle is obtained on each retinal branch vessel in at least 1 scan. The CDCS scan data, a 3-dimensional volumetric OCT scan of the optic disc scan, and a color photograph of the optic disc are used together to obtain retinal blood flow measurement on an eye. We have developed a blood flow measurement software called "Doppler optical coherence tomography of retinal circulation" (DOCTORC). This semi-automated software is used to measure total retinal blood flow, vessel cross section area, and average blood velocity. The flow of each vessel is calculated from the Doppler shift in the vessel cross-sectional area and the Doppler angle between the vessel and the OCT beam. Total retinal blood flow measurement is summed from the veins around the optic disc. The results obtained at our Doppler OCT reading center showed good reproducibility between graders and methods (<10%). Total retinal blood flow could be useful in the management of glaucoma, other retinal diseases, and retinal diseases. In glaucoma patients, OCT retinal blood flow measurement was highly correlated with visual field loss (R(2)>0.57 with visual field pattern deviation). Doppler OCT is a new method to perform rapid, noncontact, and repeatable measurement of total retinal blood flow using widely available Fourier-domain OCT instrumentation. This new technology may improve the practicality of making these measurements in clinical studies and routine clinical practice.

  19. Differences between postmortem computed tomography and conventional autopsy in a stabbing murder case

    PubMed Central

    Zerbini, Talita; da Silva, Luiz Fernando Ferraz; Ferro, Antonio Carlos Gonçalves; Kay, Fernando Uliana; Junior, Edson Amaro; Pasqualucci, Carlos Augusto Gonçalves; do Nascimento Saldiva, Paulo Hilario

    2014-01-01

    OBJECTIVE: The aim of the present work is to analyze the differences and similarities between the elements of a conventional autopsy and images obtained from postmortem computed tomography in a case of a homicide stab wound. METHOD: Comparison between the findings of different methods: autopsy and postmortem computed tomography. RESULTS: In some aspects, autopsy is still superior to imaging, especially in relation to external examination and the description of lesion vitality. However, the findings of gas embolism, pneumothorax and pulmonary emphysema and the relationship between the internal path of the instrument of aggression and the entry wound are better demonstrated by postmortem computed tomography. CONCLUSIONS: Although multislice computed tomography has greater accuracy than autopsy, we believe that the conventional autopsy method is fundamental for providing evidence in criminal investigations. PMID:25518020

  20. Complex Dynamic Development of Poliovirus Membranous Replication Complexes

    PubMed Central

    Nair, Vinod; Hansen, Bryan T.; Hoyt, Forrest H.; Fischer, Elizabeth R.; Ehrenfeld, Ellie

    2012-01-01

    Replication of all positive-strand RNA viruses is intimately associated with membranes. Here we utilize electron tomography and other methods to investigate the remodeling of membranes in poliovirus-infected cells. We found that the viral replication structures previously described as “vesicles” are in fact convoluted, branching chambers with complex and dynamic morphology. They are likely to originate from cis-Golgi membranes and are represented during the early stages of infection by single-walled connecting and branching tubular compartments. These early viral organelles gradually transform into double-membrane structures by extension of membranous walls and/or collapsing of the luminal cavity of the single-membrane structures. As the double-membrane regions develop, they enclose cytoplasmic material. At this stage, a continuous membranous structure may have double- and single-walled membrane morphology at adjacent cross-sections. In the late stages of the replication cycle, the structures are represented mostly by double-membrane vesicles. Viral replication proteins, double-stranded RNA species, and actively replicating RNA are associated with both double- and single-membrane structures. However, the exponential phase of viral RNA synthesis occurs when single-membrane formations are predominant in the cell. It has been shown previously that replication complexes of some other positive-strand RNA viruses form on membrane invaginations, which result from negative membrane curvature. Our data show that the remodeling of cellular membranes in poliovirus-infected cells produces structures with positive curvature of membranes. Thus, it is likely that there is a fundamental divergence in the requirements for the supporting cellular membrane-shaping machinery among different groups of positive-strand RNA viruses. PMID:22072780

  1. Grating-based tomography applications in biomedical engineering

    NASA Astrophysics Data System (ADS)

    Schulz, Georg; Thalmann, Peter; Khimchenko, Anna; Müller, Bert

    2017-10-01

    For the investigation of soft tissues or tissues consisting of soft and hard tissues on the microscopic level, hard X-ray phase tomography has become one of the most suitable imaging techniques. Besides other phase contrast methods grating interferometry has the advantage of higher sensitivity than inline methods and the quantitative results. One disadvantage of the conventional double-grating setup (XDGI) compared to inline methods is the limitation of the spatial resolution. This limitation can be overcome by removing the analyser grating resulting in a single-grating setup (XSGI). In order to verify the performance of XSGI concerning contrast and spatial resolution, a quantitative comparison of XSGI and XDGI tomograms of a human nerve was performed. Both techniques provide sufficient contrast to allow for the distinction of tissue types. The spatial resolution of the two-fold binned XSGI data set is improved by a factor of two in comparison to XDGI which underlies its performance in tomography of soft tissues. Another application for grating-based X-ray phase tomography is the simultaneous visualization of soft and hard tissues of a plaque-containing coronary artery. The simultaneous visualization of both tissues is important for the segmentation of the lumen. The segmented data can be used for flow simulations in order to obtain information about the three-dimensional wall shear stress distribution needed for the optimization of mechano-sensitive nanocontainers used for drug delivery.

  2. Lithospheric Structure of Central Asia

    NASA Astrophysics Data System (ADS)

    Martin, R. J.; Gulen, L.; Sun, Y.; Toksoz, M. N.

    2009-12-01

    The active tectonics of Central Asia is the result of ongoing, active continental collision between the Indian and the Eurasian plates. This geologically and tectonically complex area is also one of the most seismically active regions in the world. Previous studies in this region mostly depended on teleseismic data and the local and regional data from the stations located in China. In this study we used the local travel time data from Kazakhstan, Kyrgyzstan, Tajikistan, and Uzbekistan to study the lithospheric structure in this region. We selected the events and stations between 32°N-65°E and 45°N-85°E and focused on the areas of Pamir and Tien Shan. In this data set, there are more than 3000 P and S arrivals received at 68 stations from about 220 events. The double difference tomography is applied to relocate events and to invert for seismic structure simultaneously. Our results provide accurate locations of earthquakes and high resolution lithospheric structure in this region. We use both; the local travel times, and also the regional travel times to invert the 3D lithospheric velocity structure in this region. More than 2200 P wave phase picks were used in the inversion. The average grid spacing is 100km and the inverted grids lay on six layers. Then we use the Double Difference Tomography method developed by Zhang and Thurber (2003, 2006) to invert the 3-D P-wave velocity structure. Our tomographic results show highly heterogeneous crust and upper mantle structure for Central Asia. Some crustal low velocity zones are found beneath Tien Shan, the northern Pamir, and the Tajik depression, while high velocity anomalies are found beneath the Kazakh shield, the southern Pamir, and the Tarim basin.

  3. Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals.

    PubMed

    Chen, Dongmei; Meng, Fanzhen; Zhao, Fengjun; Xu, Cao

    2016-01-01

    Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been tested using nanophosphor material. Then, the hybrid reconstruction algorithm with KA-FEM method has been applied in cone beam X-ray luminescence tomography for small animals to overcome the ill-posed reconstruction problem, whose advantage and property have been demonstrated in fluorescence tomography imaging. The in vivo mouse experiment proved the feasibility of the proposed method.

  4. Intravascular atherosclerotic imaging with combined fluorescence and optical coherence tomography probe based on a double-clad fiber combiner

    NASA Astrophysics Data System (ADS)

    Liang, Shanshan; Saidi, Arya; Jing, Joe; Liu, Gangjun; Li, Jiawen; Zhang, Jun; Sun, Changsen; Narula, Jagat; Chen, Zhongping

    2012-07-01

    We developed a multimodality fluorescence and optical coherence tomography probe based on a double-clad fiber (DCF) combiner. The probe is composed of a DCF combiner, grin lens, and micromotor in the distal end. An integrated swept-source optical coherence tomography and fluorescence intensity imaging system was developed based on the combined probe for the early diagnoses of atherosclerosis. This system is capable of real-time data acquisition and processing as well as image display. For fluorescence imaging, the inflammation of atherosclerosis and necrotic core formed with the annexin V-conjugated Cy5.5 were imaged. Ex vivo imaging of New Zealand white rabbit arteries demonstrated the capability of the combined system.

  5. Determination of Sinkholes with Different Geophysical Techniques; A Case Study in Yarımburgaz, Küçükçekmece Lake NW Istanbul, Turkey

    NASA Astrophysics Data System (ADS)

    Karabulut, Savas; Cengiz Cinku, Mualla; Tezel, Okan; Dedecan, Hasan; Oygo, Azat

    2016-04-01

    The Yarımburgaz cave which is located in the city of Istanbul, NW Turkey plays an important host to the first human culture and preserve significant archaeological and paleontological resources. The cave was formed as a result of a subterranean stream erosion on the limestones of the Eocene Kırklareli formation. It has been reported that a double cave with upper and lower entrance chambers exist, although no geophysical research was conducted to detect the cave's trunk passages and the extend of the sediment fill inside the cave. The aim of this study was to test the preferred order for detection the response to different geophysical methods applied on the cave. We therefore carried out an a series of geophysical study to determine the size, position, and depth of sinkholes inside the caves. Integrated methodological approaches including multichannel analysis of surface wave (MASW) 2- microtremor array method, 3-single station microtremor measurements, 4- electrical tomography (ET) measuruments and 5-microgravity imaging showed that the geophysical response was succesfully applied. Based upon the flow-chart we concluded that the microgravity survey should be applied as a first step to detect the air-filled void and the geometry of the cave. The electric tomography method was well applied showing high resistivity values across the voids. The surface wave method showed that the low-velocity zones are detected in various locations of the cave. In addition we the results of MASW and ReMi methods showed clearly the density variation in the lateral direction. Fundamental frequency value above void decraese according the properties of geological units in lateral directional, especially when they are engineering rock like limestone.

  6. Seismic Velocity Structure of the San Jacinto Fault Zone from Double-Difference Tomography and Expected Distribution of Head Waves

    NASA Astrophysics Data System (ADS)

    Allam, A. A.; Ben-Zion, Y.

    2010-12-01

    We present initial results of double-difference tomographic images for the velocity structure of the San Jacinto Fault Zone (SJFZ), and related 3D forward calculations of waves in the immediate vicinity of the SJFZ. We begin by discretizing the SJFZ region with a uniform grid spacing of 500 m, extending 140 km by 80 km and down to 25 km depth. We adopt the layered 1D model of Dreger & Helmberger (1993) as a starting model for this region, and invert for 3D distributions of VP and VS with the double-difference tomography of Zhang & Thurber (2003), which makes use of absolute event-station travel times as well as relative travel times for phases from nearby event pairs. Absolute arrival times of over 78,000 P- and S-wave phase picks generated by 1127 earthquakes and recorded at 70 stations near the SJFZ are used. Only data from events with Mw greater than 2.2 are used. Though ray coverage is limited at shallow depths, we obtain relatively high-resolution images from 4 to 13 km which show a clear contrast in velocity across the NW section of the SJFZ. To the SE, in the so-called trifurcation area, the structure is more complicated, though station coverage is poorest in this region. Using the obtained image, the current event locations, and the 3D finite-difference code of Olsen (1994), we estimate the likely distributions of fault zone head waves as a tool for future deployment of instrument. We plan to conduct further studies by including more travel time picks, including those from newly-deployed stations in the SJFZ area, in order to gain a more accurate image of the velocity structure.

  7. hypoDD-A Program to Compute Double-Difference Hypocenter Locations

    USGS Publications Warehouse

    Waldhauser, Felix

    2001-01-01

    HypoDD is a Fortran computer program package for relocating earthquakes with the double-difference algorithm of Waldhauser and Ellsworth (2000). This document provides a brief introduction into how to run and use the programs ph2dt and hypoDD to compute double-difference (DD) hypocenter locations. It gives a short overview of the DD technique, discusses the data preprocessing using ph2dt, and leads through the earthquake relocation process using hypoDD. The appendices include the reference manuals for the two programs and a short description of auxiliary programs and example data. Some minor subroutines are presently in the c language, and future releases will be in c. Earthquake location algorithms are usually based on some form of Geiger’s method, the linearization of the travel time equation in a first order Taylor series that relates the difference between the observed and predicted travel time to unknown adjustments in the hypocentral coordinates through the partial derivatives of travel time with respect to the unknowns. Earthquakes can be located individually with this algorithm, or jointly when other unknowns link together the solutions to indivdual earthquakes, such as station corrections in the joint hypocenter determination (JHD) method, or the earth model in seismic tomography. The DD technique (described in detail in Waldhauser and Ellsworth, 2000) takes advantage of the fact that if the hypocentral separation between two earthquakes is small compared to the event-station distance and the scale length of velocity heterogeneity, then the ray paths between the source region and a common station are similar along almost the entire ray path (Fréchet, 1985; Got et al., 1994). In this case, the difference in travel times for two events observed at one station can be attributed to the spatial offset between the events with high accuracy. DD equations are built by differencing Geiger’s equation for earthquake location. In this way, the residual between observed and calculated travel-time difference (or double-difference) between two events at a common station are a related to adjustments in the relative position of the hypocenters and origin times through the partial derivatives of the travel times for each event with respect to the unknown. HypoDD calculates travel times in a layered velocity model (where velocity depends only on depth) for the current hypocenters at the station where the phase was recorded. The double-difference residuals for pairs of earthquakes at each station are minimized by weighted least squares using the method of singular value decomposition (SVD) or the conjugate gradients method (LSQR, Paige and Saunders, 1982). Solutions are found by iteratively adjusting the vector difference between nearby hypocentral pairs, with the locations and partial derivatives being updated after each iteration. Details about the algorithm can be found in Waldhauser and Ellsworth (2000). When the earthquake location problem is linearized using the double-difference equations, the common mode errors cancel, principally those related to the receiver-side structure. Thus we avoid the need for station corrections or high-accuracy of predicted travel times for the portion of the raypath that lies outside the focal volume. This approach is especially useful in regions with a dense distribution of seismicity, i.e. where distances between neighboring events are only a few hundred meters. The improvement of double-difference locations over ordinary JHD locations is shown in Figure 1 for about 10,000 earthquakes that occurred during the 1997 seismic crisis in the Long Valley caldera, California. While the JHD locations (left panel) show a diffuse picture of the seismicity, double-difference locations (right panel) bring structural details such as the location of active fault planes into sharp focus.

  8. Attenuation-difference radar tomography: results of a multiple-plane experiment at the U.S. Geological Survey Fractured-Rock Research Site, Mirror Lake, New Hampshire

    USGS Publications Warehouse

    Lane, J.W.; Day-Lewis, F. D.; Harris, J.M.; Haeni, F.P.; Gorelick, S.M.

    2000-01-01

    Attenuation-difference, borehole-radar tomography was used to monitor a series of sodium chloride tracer injection tests conducted within the FSE, wellfield at the U.S. Geological Survey Fractured-Rock Hydrology Research Site in Grafton County, New Hampshire, USA. Borehole-radar tomography surveys were conducted using the sequential-scanning and injection method in three boreholes that form a triangular prism of adjoining tomographic image planes. Results indicate that time-lapse tomography methods provide high-resolution images of tracer distribution in permeable zones.

  9. Characterization of normal feline renal vascular anatomy with dual-phase CT angiography.

    PubMed

    Cáceres, Ana V; Zwingenberger, Allison L; Aronson, Lillian R; Mai, Wilfried

    2008-01-01

    Helical computed tomography angiography was used to evaluate the renal vascular anatomy of potential feline renal donors. One hundred and fourteen computed tomography angiograms were reviewed. The vessels were characterized as single without bifurcation, single with bifurcation, double, or triple. Multiplicity was most commonly seen for the right renal vein (45/114 vs. 3/114 multiple left renal veins, 0/114 multiple right renal arteries, and 8/114 multiple left renal arteries). The right kidney was 13.3 times more likely than the left to have multiple renal veins. Additional vascular variants included double caudal vena cava and an accessory renal artery. For the left kidney, surgery and computed tomography angiography findings were in agreement in 92% of 74 cats. For the right kidney, surgery and computed tomography angiography findings were in agreement in 6/6 cats. Our findings of renal vascular anatomy variations in cats were similar to previous reports in humans. Identifying and recognizing the pattern of distribution of these vessels is important when performing renal transplantation.

  10. Fusion Imaging: A Novel Staging Modality in Testis Cancer

    DTIC Science & Technology

    2010-01-01

    the anatomic precision of computed tomography. To the best of our knowledge, this represents the first study of the effectiveness using fusion...imaging in evaluation of patients with testis cancer. Methods: A prospective study of 49 patients presenting to Walter Reed Army Medical Center with...incidence of testis cancer has been increasing at an annual rate of 3%, leading to a doubling in cases world-wide over the last 40 years. With the advent

  11. In vivo endoscopic Doppler optical coherence tomography imaging of the colon

    PubMed Central

    Welge, Weston A.; Barton, Jennifer K.

    2017-01-01

    Background and Objective Colorectal cancer remains the second deadliest cancer in the United States. Several screening methods exist, however detection of small polyps remains a challenge. Optical coherence tomography has been demonstrated to be capable of detecting lesions as small as 1 mm in the mouse colon, but detection is based on measuring a doubling of the mucosa thickness. The colon microvasculature may be an attractive biomarker of early tumor development because tumor vessels are characterized by irregular structure and dysfunction. Our goal was to develop an endoscopic method of detecting and segmenting colon vessels using Doppler optical coherence tomography to enable future studies for improving early detection and development of novel chemopreventive agents. Method We conducted in vivo colon imaging in an azoxymethane (AOM)-treated mouse model of colorectal cancer using a miniature endoscope and a swept-source OCT system at 1040 nm with a 16 kHz sweep rate. We applied the Kasai autocorrelation algorithm to laterally oversampled OCT B-scans to resolve vascular flow in the mucosa and submucosa. Vessels were segmented by applying a series of image processing steps: (1) intensity thresholding, (2) two-dimensional matched filtering, and (3) histogram segmentation. Results We observed differences in the vessels sizes and spatial distribution in a mature adenoma compared to surrounding undiseased tissue and compared the results with histology. We also imaged flow in four young mice (2 AOM-treated and 2 control) showing no significant differences, which is expected so early after carcinogen exposure. We also present flow images of adenoma in a living mouse and a euthanized mouse to demonstrate that no flow is detected after euthanasia. Conclusion We present, to the best of our knowledge, the first Doppler OCT images of in vivo mouse colon collected with a fiber-based endoscope. We also describe a fast and robust image processing method for segmenting vessels in the colon. These results suggest that Doppler OCT is a promising imaging modality for vascular imaging in the colon that requires no exogenous contrast agents. PMID:27546786

  12. Frequency Domain Ultrasound Waveform Tomography: Breast Imaging Using a Ring Transducer

    PubMed Central

    Sandhu, G Y; Li, C; Roy, O; Schmidt, S; Duric, N

    2016-01-01

    Application of the frequency domain acoustic wave equation on data acquired from ultrasound tomography scans is shown to yield high resolution sound speed images on the order of the wavelength of the highest reconstructed frequency. Using a signal bandwidth of 0.4–1 MHz and an average sound speed of 1500 m/s, the resolution is approximately 1.5 mm. The quantitative sound speed values and morphology provided by these images have the potential to inform diagnosis and classification of breast disease. In this study, we present the formalism, practical application, and in vivo results of waveform tomography applied to breast data gathered by two different ultrasound tomography scanners that utilize ring transducers. The formalism includes a review of frequency domain modeling of the wave equation using finite difference operators as well as a review of the gradient descent method for the iterative reconstruction scheme. It is shown that the practical application of waveform tomography requires an accurate starting model, careful data processing, and a method to gradually incorporate higher frequency information into the sound speed reconstruction. Following these steps resulted in high resolution quantitative sound speed images of the breast. These images show marked improvement relative to commonly used ray tomography reconstruction methods. The robustness of the method is demonstrated by obtaining similar results from two different ultrasound tomography devices. We also compare our method to MRI to demonstrate concordant findings. The clinical data used in this work was obtained from a HIPAA compliant clinical study (IRB 040912M1F). PMID:26110909

  13. Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes

    PubMed Central

    ZAHABIUN, Farzaneh; SADJJADI, Seyed Mahmoud; ESFANDIARI, Farideh

    2015-01-01

    Background: Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. Methods: A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. Results: The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Conclusion: Using this method is cost effective and fast for mounting of small nematodes comparing to classic method. PMID:26811729

  14. Evidence for a low permeability fluid trap in the Nový Kostel Seismic Zone, Czech Republic, using double-difference tomography

    NASA Astrophysics Data System (ADS)

    Alexandrakis, C.; Calo, M.; Vavrycuk, V.

    2012-12-01

    The West Bohemia/Vogtland region is the border area between the Czech Republic and Germany known for frequent occurrences of earthquake swarms. The most prominent earthquake swarms occurred recently in 1985/86, 1997, 2000 (Fischer and Horálek, 2003) and 2008 (Fischer et al., 2010). They comprised thousands of microearthquakes, their duration was between 2 weeks to 2 months, and the activity focused typically at depths ranging from 7 to 12 km. The seismic activity is concentrated mostly at the same epicentral area, called the Nový Kostel Zone. This zone is located on the edge of the Cheb Basin, Eger Rift, and at the junction of the Mariánské-Lázně Fault with the Počátky-Plesná Shear Zone. Numerous gas vents and mineral springs within and around the Cheb Basin indicate that uprising magmatic fluids may act as a swarm trigger. In this study, we apply double-difference tomography to investigate the structure within and around the Nový Kostel focal zone. We use data from the 2008 earthquake swarm, as it has been extensively analyzed, and focal mechanisms, principal faults, tectonic stress, source migration and other basic characteristics are known. We selected about 500 microearthquakes recorded at 22 local seismic stations of the West Bohemia Network (WEBNET). The events were inverted for the 3-D seismic structure using the TomoDD code (Zhang and Thurber, 2003) and post-processed using the Weighted Average Model method (Calò et al., 2011). The application of double-difference tomography is advantageous for this setting as swarm foci are closely spaced and form a dense cluster. The geometry of the focal zone and the WEBNET network configuration offer good raypath coverage in all directions. Applying double-difference tomography we produce and interpret 3-D models of the P and S velocities. In this work, we interpret 3-D models of the P velocity and P-to-S ratio in and around the focal zone. The P-to-S model was obtained by calculating directly the ratio between the P and S velocity models. We find that average P velocities in the focal zone are higher than those around it. High values concentrate along the main active fault with strike of 169 degrees. The model of the P-to-S ratio shows several distinct structures. An area of high P-to-S ratio is mainly identified with the focal zone, and an area of low P-to-S ratio is above the focal zone. Past studies of the P-to-S ratio have linked high ratios with areas of high fracturing and fluid concentration, and low ratios with low permeability and low fluid content. Following this interpretation, the resolved P-to-S ratio model suggests a low permeability layer just above the focal zone. This layer probably acts as a low permeability cap, leading to a change in the stress field and subsequent fracturing. The base of this layer corresponds with the shallowest ruptures. In addition, high ratios follow the fault plane, suggesting high fluid concentration in the focal zone. References: Calò, M., C. Dorbath, F. H. Cornet and N. Cuenot, 2011. Geophys. J. Int., 186, 1295-1314. Fischer, T. and J. Horálek, 2003. J. Geodyn., 35, 125-144. Fischer, T., J. Horálek, J. Michálek and A. Boušková, 2010. J. Seismol., 14, 665-682. Zhang, H. and C. Thurber, 2003. Bull. Seism. Soc. Am. 93, 1875-1889.

  15. Image Quality and Radiation Exposure Comparison of a Double High-Pitch Acquisition for Coronary Computed Tomography Angiography Versus Standard Retrospective Spiral Acquisition in Patients With Atrial Fibrillation.

    PubMed

    Prazeres, Carlos Eduardo Elias Dos; Magalhães, Tiago Augusto; de Castro Carneiro, Adriano Camargo; Cury, Roberto Caldeira; de Melo Moreira, Valéria; Bello, Juliana Hiromi Silva Matsumoto; Rochitte, Carlos Eduardo

    The aim of this study was to compare image quality and radiation dose of coronary computed tomography (CT) angiography performed with dual-source CT scanner using 2 different protocols in patients with atrial fibrillation. Forty-seven patients with AF underwent 2 different acquisition protocols: double high-pitch (DHP) spiral acquisition and retrospective spiral acquisition. The image quality was ranked according to a qualitative score by 2 experts: 1, no evident motion; 2, minimal motion not influencing coronary artery luminal evaluation; and 3, motion with impaired luminal evaluation. A third expert solved any disagreement. A total of 732 segments were evaluated. The DHP group (24 patients, 374 segments) showed more segments classified as score 1 than the retrospective spiral acquisition group (71.3% vs 37.4%). Image quality evaluation agreement was high between observers (κ = 0.8). There was significantly lower radiation exposure for the DHP group (3.65 [1.29] vs 23.57 [10.32] mSv). In this original direct comparison, a DHP spiral protocol for coronary CT angiography acquisition in patients with atrial fibrillation resulted in lower radiation exposure and superior image quality compared with conventional spiral retrospective acquisition.

  16. Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes.

    PubMed

    Zahabiun, Farzaneh; Sadjjadi, Seyed Mahmoud; Esfandiari, Farideh

    2015-01-01

    Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Using this method is cost effective and fast for mounting of small nematodes comparing to classic method.

  17. Artefacts of PET/CT images

    PubMed Central

    Pettinato, C; Nanni, C; Farsad, M; Castellucci, P; Sarnelli, A; Civollani, S; Franchi, R; Fanti, S; Marengo, M; Bergamini, C

    2006-01-01

    Positron emission tomography (PET) is a non-invasive imaging modality, which is clinically widely used both for diagnosis and accessing therapy response in oncology, cardiology and neurology. Fusing PET and CT images in a single dataset would be useful for physicians who could read the functional and the anatomical aspects of a disease in a single shot. The use of fusion software has been replaced in the last few years by integrated PET/CT systems, which combine a PET and a CT scanner in the same gantry. CT images have the double function to correct PET images for attenuation and can fuse with PET for a better visualization and localization of lesions. The use of CT for attenuation correction yields several advantages in terms of accuracy and patient comfort, but can also introduce several artefacts on PET-corrected images. PET/CT image artefacts are due primarily to metallic implants, respiratory motion, use of contrast media and image truncation. This paper reviews different types artefacts and their correction methods. PET/CT improves image quality and image accuracy. However, to avoid possible pitfalls the simultaneous display of both Computed Tomography Attenuation Corrected (CTAC) and non corrected PET images, side by side with CT images is strongly recommended. PMID:21614340

  18. High-resolution imaging of basal cell carcinoma: a comparison between multiphoton microscopy with fluorescence lifetime imaging and reflectance confocal microscopy.

    PubMed

    Manfredini, Marco; Arginelli, Federica; Dunsby, Christopher; French, Paul; Talbot, Clifford; König, Karsten; Pellacani, Giovanni; Ponti, Giovanni; Seidenari, Stefania

    2013-02-01

    The aim of this study was to compare morphological aspects of basal cell carcinoma (BCC) as assessed by two different imaging methods: in vivo reflectance confocal microscopy (RCM) and multiphoton tomography with fluorescence lifetime imaging implementation (MPT-FLIM). The study comprised 16 BCCs for which a complete set of RCM and MPT-FLIM images were available. The presence of seven MPT-FLIM descriptors was evaluated. The presence of seven RCM equivalent parameters was scored in accordance to their extension. Chi-squared test with Fisher's exact test and Spearman's rank correlation coefficient were determined between MPT-FLIM scores and adjusted-RCM scores. MPT-FLIM and RCM descriptors of BCC were coupled to match the descriptors that define the same pathological structures. The comparison included: Streaming and Aligned elongated cells, Streaming with multiple directions and Double alignment, Palisading (RCM) and Palisading (MPT-FLIM), Typical tumor islands, and Cell islands surrounded by fibers, Dark silhouettes and Phantom islands, Plump bright cells and Melanophages, Vessels (RCM), and Vessels (MPT-FLIM). The parameters that were significantly correlated were Melanophages/Plump Bright Cells, Aligned elongated cells/Streaming, Double alignment/Streaming with multiple directions, and Palisading (MPT-FLIM)/Palisading (RCM). According to our data, both methods are suitable to image BCC's features. The concordance between MPT-FLIM and RCM is high, with some limitations due to the technical differences between the two devices. The hardest difficulty when comparing the images generated by the two imaging modalities is represented by their different field of view. © 2012 John Wiley & Sons A/S.

  19. Early Dose Response to Yttrium-90 Microsphere Treatment of Metastatic Liver Cancer by a Patient-Specific Method Using Single Photon Emission Computed Tomography and Positron Emission Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Janice M.; Department of Radiation Oncology, Wayne State University, Detroit, MI; Wong, C. Oliver

    2009-05-01

    Purpose: To evaluate a patient-specific single photon emission computed tomography (SPECT)-based method of dose calculation for treatment planning of yttrium-90 ({sup 90}Y) microsphere selective internal radiotherapy (SIRT). Methods and Materials: Fourteen consecutive {sup 90}Y SIRTs for colorectal liver metastasis were retrospectively analyzed. Absorbed dose to tumor and normal liver tissue was calculated by partition methods with two different tumor/normal liver vascularity ratios: an average 3:1 and a patient-specific ratio derived from pretreatment technetium-99m macroaggregated albumin SPECT. Tumor response was quantitatively evaluated from fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography scans. Results: Positron emission tomography showed a significant decrease in total tumor standardizedmore » uptake value (average, 52%). There was a significant difference in the tumor absorbed dose between the average and specific methods (p = 0.009). Response vs. dose curves fit by linear and linear-quadratic modeling showed similar results. Linear fit r values increased for all tumor response parameters with the specific method (+0.20 for mean standardized uptake value). Conclusion: Tumor dose calculated with the patient-specific method was more predictive of response in liver-directed {sup 90}Y SIRT.« less

  20. Slab seismicity in the Western Hellenic Subduction Zone: Constraints from tomography and double-difference relocation

    NASA Astrophysics Data System (ADS)

    Halpaap, Felix; Rondenay, Stéphane; Ottemöller, Lars

    2016-04-01

    The Western Hellenic subduction zone is characterized by a transition from oceanic to continental subduction. In the southern oceanic portion of the system, abundant seismicity reaches intermediate depths of 100-120 km, while the northern continental portion rarely exhibits deep earthquakes. Our study aims to investigate how this oceanic-continental transition affects fluid release and related seismicity along strike, by focusing on the distribution of intermediate depth earthquakes. To obtain a detailed image of the seismicity, we carry out a tomographic inversion for P- and S-velocities and double-difference earthquake relocation using a dataset of unprecedented spatial coverage in this area. Here we present results of these analyses in conjunction with high-resolution profiles from migrated receiver function images obtained from the MEDUSA experiment. We generate tomographic models by inverting data from 237 manually picked, well locatable events recorded at up to 130 stations. Stations from the permanent Greek network and the EGELADOS experiment supplement the 3-D coverage of the modeled domain, which covers a large part of mainland Greece and surrounding offshore areas. Corrections for the sphericity of the Earth and our update to the SIMULR16 package, which now allows S-inversion, help improve our previous models. Flexible gridding focusses the inversion on the domains of highest gradient around the slab, and we evaluate the resolution with checker board tests. We use the resulting velocity model to relocate earthquakes via the Double-Difference method, using a large dataset of differential traveltimes obtained by crosscorrelation of seismograms. Tens of earthquakes align along two planes forming a double seismic zone in the southern, oceanic portion of the subduction zone. With increasing subduction depth, the earthquakes appear closer to the center of the slab, outlining probable deserpentinization of the slab and concomitant eclogitization of dry crustal rocks. Against expectations, we relocate one robust deep event at ≈70 km depth in the northern, continental part of the subduction zone.

  1. The crustal and mantle velocity structure in central Asia from 3D traveltime tomography

    NASA Astrophysics Data System (ADS)

    Sun, Y.; Martin, R. V.; Toksoz, M. N.; Pei, S.

    2010-12-01

    The lithospheric structure in central Asia features large blocks such as the Indian plate, the Afghan block, the Turan plate, and the Tarim block. This geologically and tectonically complicated area is also one of the most seismically active regions in the world. We developed P- and S- wave velocity structures of the central Asia in the crust using the traveltime data from Kyrgyzstan, Tajikistan, Kazakhstan, and Uzbek. We chose the events and stations between 32N65E and 45N85E and focused on the areas of Pamir and western Tianshan. In this data set, there are more than 6000 P and S arrivals received at 80 stations from about 300 events. The double difference tomography is applied to relocate events and to invert for seismic structures simultaneously. Our results provide accurate locations of earthquakes and high resolution crustal structure in this region. To extend the model deeper into the mantle through the upper mantle transition zone, ISC/EHB data for P and PP phases are combined with the ABCE data. To counteract the “smearing effect,” the crust and upper mantle velocity structure, derived from regional travel-times, is used. An adaptive grid method based on ray density is used in the inversion. A P-wave velocity model extending down to a depth of 2000 km is obtained. regional-teleseismic tomography provides a high-resolution, 3-D P-wave velocity model for the crust, upper mantle, and the transition zone. The crustal models correlate well with geologic and tectonic features. The upper mantle tomograms show the images of Tian Shan. The slab geometry is quite complex, reflecting the history of the changes in the plate motions and collision processes. Vp/Vs tomography was also determined in the study region, and an attenuation tomography was obtained as well.

  2. Improving lateral resolution and image quality of optical coherence tomography by the multi-frame superresolution technique for 3D tissue imaging.

    PubMed

    Shen, Kai; Lu, Hui; Baig, Sarfaraz; Wang, Michael R

    2017-11-01

    The multi-frame superresolution technique is introduced to significantly improve the lateral resolution and image quality of spectral domain optical coherence tomography (SD-OCT). Using several sets of low resolution C-scan 3D images with lateral sub-spot-spacing shifts on different sets, the multi-frame superresolution processing of these sets at each depth layer reconstructs a higher resolution and quality lateral image. Layer by layer processing yields an overall high lateral resolution and quality 3D image. In theory, the superresolution processing including deconvolution can solve the diffraction limit, lateral scan density and background noise problems together. In experiment, the improved lateral resolution by ~3 times reaching 7.81 µm and 2.19 µm using sample arm optics of 0.015 and 0.05 numerical aperture respectively as well as doubling the image quality has been confirmed by imaging a known resolution test target. Improved lateral resolution on in vitro skin C-scan images has been demonstrated. For in vivo 3D SD-OCT imaging of human skin, fingerprint and retina layer, we used the multi-modal volume registration method to effectively estimate the lateral image shifts among different C-scans due to random minor unintended live body motion. Further processing of these images generated high lateral resolution 3D images as well as high quality B-scan images of these in vivo tissues.

  3. Natural microseismicity investigated using double-difference tomography: a 3D look at the 2008 swarm in the Novy Kostel area, Czech Republic

    NASA Astrophysics Data System (ADS)

    Alexandrakis, C.; Calo, M.; Bouchaala, F.; Vavrycuk, V.

    2012-04-01

    The Novy Kostel region in West Bohemia is an area prone to periodic bursts of natural microseismic activity. In this study, we use 476 events from the October 2008 earthquake swarm recorded on the WEBNET seismic network. The foci occurred on the northern extension of the Marianske-Lazne Fault near the town of Novy Kostel in the Czech Republic. Initial source locations indicated a rupture zone approximately 3 km along the fault with the sources spread over 4 km depth, centered at 9 km. We use the double-difference tomography method to study the fault structure by relocating the sources and inverting for the P and S velocities in the rupture region. Events are first relocated using the HypoDD program (Waldhauser and Ellsworth, 2000) using both catalog and cross-correlated datasets. These datasets, along with the absolute time picks are then used by the TomoDD program (Zhang and Thurber, 2003) to iteratively relocate the sources and invert for the 3D seismic structure. This dataset is ideal for this procedure as the cluster is very condensed and the WEBNET network offers ray coverage in all directions. The relocated events flatten onto a fault plane striking at 169 degrees NE. This fault plane has three sections with distinct dip angles. At the shallowest (up to 8 km) and deepest (10 - 11 km) parts of the fault, the dip is shallow, whereas the middle section has a steep dip angle. Most events occur at the deeper part of the middle section. The inverted velocities correspond well to results from regional seismic refraction surveys (e.g., CELEBRATION 2000). Here, more details of the 3D velocity structure are revealed. As expected, velocities to the east of the fault are overall higher, corresponding to the uplifted northern margin of the Eger Rift. Finer structures surrounding the source region are also resolved.

  4. Directional sinogram interpolation for sparse angular acquisition in cone-beam computed tomography.

    PubMed

    Zhang, Hua; Sonke, Jan-Jakob

    2013-01-01

    Cone-beam (CB) computed tomography (CT) is widely used in the field of medical imaging for guidance. Inspired by Betram's directional interpolation (BDI) methods, directional sinogram interpolation (DSI) was implemented to generate more CB projections by optimized (iterative) double-orientation estimation in sinogram space and directional interpolation. A new CBCT was subsequently reconstructed with the Feldkamp algorithm using both the original and interpolated CB projections. The proposed method was evaluated on both phantom and clinical data, and image quality was assessed by correlation ratio (CR) between the interpolated image and a gold standard obtained from full measured projections. Additionally, streak artifact reduction and image blur were assessed. In a CBCT reconstructed by 40 acquired projections over an arc of 360 degree, streak artifacts dropped 20.7% and 6.7% in a thorax phantom, when our method was compared to linear interpolation (LI) and BDI methods. Meanwhile, image blur was assessed by a head-and-neck phantom, where image blur of DSI was 20.1% and 24.3% less than LI and BDI. When our method was compared to LI and DI methods, CR increased by 4.4% and 3.1%. Streak artifacts of sparsely acquired CBCT were decreased by our method and image blur induced by interpolation was constrained to below other interpolation methods.

  5. Towards Crustal Structure of Java Island (Sunda Arc) from Ambient Seismic Noise Tomography

    NASA Astrophysics Data System (ADS)

    Widiyantoro, Sri; Zulhan, Zulfakriza; Martha, Agustya; Saygin, Erdinc; Cummins, Phil

    2015-04-01

    In our previous studies, P- and S-wave velocity structures beneath the Sunda Arc were successfully imaged using a global data set and a nested regional-global tomographic method was employed. To obtain more detailed P- and S-wave velocity structures beneath Java, in the central part of the Sunda Arc, we then used local data sets, i.e. newline from the MErapi AMphibious EXperiment (MERAMEX) and the Meteorological, Climatological and Geophysical Agency (MCGA), as well as employed a double-difference technique for tomographic imaging. The results of the imaging show e.g. that P- and S-wave velocities are significantly reduced in the uppermost mantle beneath central Java. In order to obtain detailed crustal structure information beneath Java, the Ambient Noise Tomography (ANT) method was used. The application of this method to the MERAMEX data has produced a good crustal model beneath central Java. We continue our experiment to image crustal structure of eastern Java. We have used seismic waveform data recorded by 22 MCGA stationary seismographic stations and 25 portable seismographs installed for 2 to 8 weeks. The data were processed to obtain waveforms of cross-correlated noise between pairs of seismographic stations. Our preliminary results presented here indicate that the Kendeng zone, an area of low gravity anomaly, is associated with a low velocity zone. On the other hand, the southern mountain range, which has a high gravity anomaly, is related to a high velocity anomaly (as shown by our tomographic images). In future work we will install more seismographic stations in eastern Java as well as in western Java to conduct ANT imaging for the whole of Java Island. The expected result combined with the mantle velocity models resulting from our body wave tomography will allow for accurate location of earthquake hypocenters and determination of regional tectonic structures. Both of these are valuable for understanding seismic hazard in Java, the most densely populated island in the world.

  6. Fast Bayesian experimental design: Laplace-based importance sampling for the expected information gain

    NASA Astrophysics Data System (ADS)

    Beck, Joakim; Dia, Ben Mansour; Espath, Luis F. R.; Long, Quan; Tempone, Raúl

    2018-06-01

    In calculating expected information gain in optimal Bayesian experimental design, the computation of the inner loop in the classical double-loop Monte Carlo requires a large number of samples and suffers from underflow if the number of samples is small. These drawbacks can be avoided by using an importance sampling approach. We present a computationally efficient method for optimal Bayesian experimental design that introduces importance sampling based on the Laplace method to the inner loop. We derive the optimal values for the method parameters in which the average computational cost is minimized according to the desired error tolerance. We use three numerical examples to demonstrate the computational efficiency of our method compared with the classical double-loop Monte Carlo, and a more recent single-loop Monte Carlo method that uses the Laplace method as an approximation of the return value of the inner loop. The first example is a scalar problem that is linear in the uncertain parameter. The second example is a nonlinear scalar problem. The third example deals with the optimal sensor placement for an electrical impedance tomography experiment to recover the fiber orientation in laminate composites.

  7. Seismic moment tensor inversion using 3D velocity model and its application to the 2013 Lushan earthquake sequence

    NASA Astrophysics Data System (ADS)

    Zhu, Lupei; Zhou, Xiaofeng

    2016-10-01

    Source inversion of small-magnitude events such as aftershocks or mine collapses requires use of relatively high frequency seismic waveforms which are strongly affected by small-scale heterogeneities in the crust. In this study, we developed a new inversion method called gCAP3D for determining general moment tensor of a seismic source using Green's functions of 3D models. It inherits the advantageous features of the ;Cut-and-Paste; (CAP) method to break a full seismogram into the Pnl and surface-wave segments and to allow time shift between observed and predicted waveforms. It uses grid search for 5 source parameters (relative strengths of the isotropic and compensated-linear-vector-dipole components and the strike, dip, and rake of the double-couple component) that minimize the waveform misfit. The scalar moment is estimated using the ratio of L2 norms of the data and synthetics. Focal depth can also be determined by repeating the inversion at different depths. We applied gCAP3D to the 2013 Ms 7.0 Lushan earthquake and its aftershocks using a 3D crustal-upper mantle velocity model derived from ambient noise tomography in the region. We first relocated the events using the double-difference method. We then used the finite-differences method and reciprocity principle to calculate Green's functions of the 3D model for 20 permanent broadband seismic stations within 200 km from the source region. We obtained moment tensors of the mainshock and 74 aftershocks ranging from Mw 5.2 to 3.4. The results show that the Lushan earthquake is a reverse faulting at a depth of 13-15 km on a plane dipping 40-47° to N46° W. Most of the aftershocks occurred off the main rupture plane and have similar focal mechanisms to the mainshock's, except in the proximity of the mainshock where the aftershocks' focal mechanisms display some variations.

  8. Congenital anomalies of the left brachiocephalic vein detected in adults on computed tomography.

    PubMed

    Yamamuro, Hiroshi; Ichikawa, Tamaki; Hashimoto, Jun; Ono, Shun; Nagata, Yoshimi; Kawada, Shuichi; Kobayashi, Makiko; Koizumi, Jun; Shibata, Takeo; Imai, Yutaka

    2017-10-01

    Anomalous left brachiocephalic vein (BCV) is a rare and less known systemic venous anomaly. We evaluated congenital anomalies of the left BCV in adults detected during computed tomography (CT) examinations. This retrospective study included 81,425 patients without congenital heart disease who underwent chest CT. We reviewed the recorded reports and CT images for congenital anomalies of the left BCV including aberrant and supernumerary BCVs. The associated congenital aortic anomalies were assessed. Among 73,407 cases at a university hospital, 22 (16 males, 6 females; mean age, 59 years) with aberrant left BCVs were found using keyword research on recorded reports (0.03%). Among 8018 cases at the branch hospital, 5 (4 males, 1 female; mean age, 67 years) with aberrant left BCVs were found using CT image review (0.062%). There were no significant differences in incidences of aberrant left BCV between the two groups. Two cases had double left BCVs. Eleven cases showed high aortic arches. Two cases had the right aortic arch, one case had an incomplete double aortic arch, and one case was associated with coarctation. Aberrant left BCV on CT examination in adults was extremely rare. Some cases were associated with aortic arch anomalies.

  9. Imaging of 3-D seismic velocity structure of Southern Sumatra region using double difference tomographic method

    NASA Astrophysics Data System (ADS)

    Lestari, Titik; Nugraha, Andri Dian

    2015-04-01

    Southern Sumatra region has a high level of seismicity due to the influence of the subduction system, Sumatra fault, Mentawai fault and stretching zone activities. The seismic activities of Southern Sumatra region are recorded by Meteorological Climatological and Geophysical Agency (MCGA's) Seismograph network. In this study, we used earthquake data catalog compiled by MCGA for 3013 events from 10 seismic stations around Southern Sumatra region for time periods of April 2009 - April 2014 in order to invert for the 3-D seismic velocities structure (Vp, Vs, and Vp/Vs ratio). We applied double-difference seismic tomography method (tomoDD) to determine Vp, Vs and Vp/Vs ratio with hypocenter adjustment. For the inversion procedure, we started from the initial 1-D seismic velocity model of AK135 and constant Vp/Vs of 1.73. The synthetic travel time from source to receiver was calculated using ray pseudo-bending technique, while the main tomographic inversion was applied using LSQR method. The resolution model was evaluated using checkerboard test and Derivative Weigh Sum (DWS). Our preliminary results show low Vp and Vs anomalies region along Bukit Barisan which is may be associated with weak zone of Sumatran fault and migration of partial melted material. Low velocity anomalies at 30-50 km depth in the fore arc region may indicated the hydrous material circulation because the slab dehydration. We detected low seismic seismicity in the fore arc region that may be indicated as seismic gap. It is coincides contact zone of high and low velocity anomalies. And two large earthquakes (Jambi and Mentawai) also occurred at the contact of contrast velocity.

  10. Imaging of 3-D seismic velocity structure of Southern Sumatra region using double difference tomographic method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lestari, Titik, E-mail: t2klestari@gmail.com; Faculty of Earth Science and Technology, Bandung Institute of Technology, Jalan Ganesa No.10, Bandung 40132; Nugraha, Andri Dian, E-mail: nugraha@gf.itb.ac.id

    2015-04-24

    Southern Sumatra region has a high level of seismicity due to the influence of the subduction system, Sumatra fault, Mentawai fault and stretching zone activities. The seismic activities of Southern Sumatra region are recorded by Meteorological Climatological and Geophysical Agency (MCGA’s) Seismograph network. In this study, we used earthquake data catalog compiled by MCGA for 3013 events from 10 seismic stations around Southern Sumatra region for time periods of April 2009 – April 2014 in order to invert for the 3-D seismic velocities structure (Vp, Vs, and Vp/Vs ratio). We applied double-difference seismic tomography method (tomoDD) to determine Vp, Vsmore » and Vp/Vs ratio with hypocenter adjustment. For the inversion procedure, we started from the initial 1-D seismic velocity model of AK135 and constant Vp/Vs of 1.73. The synthetic travel time from source to receiver was calculated using ray pseudo-bending technique, while the main tomographic inversion was applied using LSQR method. The resolution model was evaluated using checkerboard test and Derivative Weigh Sum (DWS). Our preliminary results show low Vp and Vs anomalies region along Bukit Barisan which is may be associated with weak zone of Sumatran fault and migration of partial melted material. Low velocity anomalies at 30-50 km depth in the fore arc region may indicated the hydrous material circulation because the slab dehydration. We detected low seismic seismicity in the fore arc region that may be indicated as seismic gap. It is coincides contact zone of high and low velocity anomalies. And two large earthquakes (Jambi and Mentawai) also occurred at the contact of contrast velocity.« less

  11. Application of optical longitudinal tomography for dental introscopy

    NASA Astrophysics Data System (ADS)

    Levin, Gennady G.; Burgansky, Alexander A.; Levandovski, Alexei G.

    1997-08-01

    A new method of dental introscopy in-vitro is suggested by the authors. This method implies the usage of longitudinal tomography techniques and is characterized by non-invasive and non-harmful diagnostics features, as well as interactive regime of image reconstruction which lets an operator (doctor) to control the diagnostics process in real time. He-Ne laser emission is used for obtaining of the projections. By the means of longitudinal tomography, images of different sections of an object (tooth) can be reconstructed. An experiment was held by the authors in which 100 projections of a tooth (premolar) were obtained and images of 10 different sections were reconstructed. These images were later compared to real sections of the tooth. This experiment proved that optical longitudinal tomography can be successfully used for dental introscopy. Authors claim that optical tomographic methods can be used for diagnostics of other biological objects as well. Such objects are characterized by spatial geometrical anisotropy (tubular bones, phalanxes of fingers, penis, etc.). It is especially promising to use this method for children's dentistry. the authors discuss some features of the data acquisition system for optical longitudinal tomography. Reconstruction algorithms are described. The results of experimental reconstruction are presented and advantages of this diagnostics method are discussed.

  12. Seismicity and structure of Nazca Plate subduction zone in southern Peru

    NASA Astrophysics Data System (ADS)

    Lim, H.; Kim, Y.; Clayton, R. W.; Thurber, C. H.

    2016-12-01

    We define subducting plate geometries in the Nazca subduction zone by (re)locating intra-slab earthquakes in southern Peru (2-18°S) and taking previously published converted phase analysis results, to clarify the slab geometry and inferred relationships to the seismicity. We also provide both P- and S-wave velocities of the subducting Nazca Plate and mantle wedge portions close to the slab using double-difference tomography (Zhang and Thurber, 2003) to understand upper plate volcanism and subduction process. A total of 492 regional earthquakes from August 2008 to February 2013 recorded from the dense seismic array (PeruSE, 2013) are selected for the relocation and tomography. The relocated seismicity shows a smooth contortion in the slab-dip transition zone for 400 km between the shallow (25°)-to-flat dipping interface in the north and 40°-dipping interface in the south. We find a significant slab-dip difference (up to 10°) between our results and previously published slab models along the profile region sampling the normal-dip slab at depth (>100 km). Robust features in both P- and S-wave tomography inversions are dipping low-velocity slabs down to 100 km transitioning to higher-velocities at 100-140 km in both flat slab and dipping slab regions. Differences in the velocities of the mantle wedge between the two regions may indicate different hydration states in the wedge.

  13. Improving diffuse optical tomography with structural a priori from fluorescence diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Ma, Wenjuan; Gao, Feng; Duan, Linjing; Zhu, Qingzhen; Wang, Xin; Zhang, Wei; Wu, Linhui; Yi, Xi; Zhao, Huijuan

    2012-03-01

    We obtain absorption and scattering reconstructed images by incorporating a priori information of target location obtained from fluorescence diffuse optical tomography (FDOT) into the diffuse optical tomography (DOT). The main disadvantage of DOT lies in the low spatial resolution resulting from highly scattering nature of tissue in the near-infrared (NIR), but one can use it to monitor hemoglobin concentration and oxygen saturation simultaneously, as well as several other cheomphores such as water, lipids, and cytochrome-c-oxidase. Up to date, extensive effort has been made to integrate DOT with other imaging modalities such as MRI, CT, to obtain accurate optical property maps of the tissue. However, the experimental apparatus is intricate. In this study, DOT image reconstruction algorithm that incorporates a prior structural information provided by FDOT is investigated in an attempt to optimize recovery of a simulated optical property distribution. By use of a specifically designed multi-channel time-correlated single photon counting system, the proposed scheme in a transmission mode is experimentally validated to achieve simultaneous reconstruction of the fluorescent yield, lifetime, absorption and scattering coefficient. The experimental results demonstrate that the quantitative recovery of the tumor optical properties has doubled and the spatial resolution improves as well by applying the new improved method.

  14. Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography

    PubMed Central

    Affatato, Saverio; Zanini, Filippo; Carmignato, Simone

    2017-01-01

    Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations. PMID:28772616

  15. A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept.

    PubMed

    Men, Kuo; Dai, Jianrong

    2017-12-01

    To develop a projection quality-driven tube current modulation method in cone-beam computed tomography for image-guided radiotherapy based on the prior attenuation information obtained by the planning computed tomography and then evaluate its effect on a reduction in the imaging dose. The QCKV-1 phantom with different thicknesses (0-400 mm) of solid water upon it was used to simulate different attenuation (μ). Projections were acquired with a series of tube current-exposure time product (mAs) settings, and a 2-dimensional contrast to noise ratio was analyzed for each projection to create a lookup table of mAs versus 2-dimensional contrast to noise ratio, μ. Before a patient underwent computed tomography, the maximum attenuation [Formula: see text] within the 95% range of each projection angle (θ) was estimated according to the planning computed tomography images. Then, a desired 2-dimensional contrast to noise ratio value was selected, and the mAs setting at θ was calculated with the lookup table of mAs versus 2-dimensional contrast to noise ratio,[Formula: see text]. Three-dimensional cone-beam computed tomography images were reconstructed using the projections acquired with the selected mAs. The imaging dose was evaluated with a polymethyl methacrylate dosimetry phantom in terms of volume computed tomography dose index. Image quality was analyzed using a Catphan 503 phantom with an oval body annulus and a pelvis phantom. For the Catphan 503 phantom, the cone-beam computed tomography image obtained by the projection quality-driven tube current modulation method had a similar quality to that of conventional cone-beam computed tomography . However, the proposed method could reduce the imaging dose by 16% to 33% to achieve an equivalent contrast to noise ratio value. For the pelvis phantom, the structural similarity index was 0.992 with a dose reduction of 39.7% for the projection quality-driven tube current modulation method. The proposed method could reduce the additional dose to the patient while not degrading the image quality for cone-beam computed tomography. The projection quality-driven tube current modulation method could be especially beneficial to patients who undergo cone-beam computed tomography frequently during a treatment course.

  16. Microinterferometric optical phase tomography for measuring small, asymmetric refractive-index differences in the profiles of optical fibers and fiber devices.

    PubMed

    Bachim, Brent L; Gaylord, Thomas K

    2005-01-20

    A new technique, microinterferometric optical phase tomography, is introduced for use in measuring small, asymmetric refractive-index differences in the profiles of optical fibers and fiber devices. The method combines microscopy-based fringe-field interferometry with parallel projection-based computed tomography to characterize fiber index profiles. The theory relating interference measurements to the projection set required for tomographic reconstruction is given, and discrete numerical simulations are presented for three test index profiles that establish the technique's ability to characterize fiber with small, asymmetric index differences. An experimental measurement configuration and specific interferometry and tomography practices employed in the technique are discussed.

  17. Travel-time tomography in shallow water: experimental demonstration at an ultrasonic scale.

    PubMed

    Roux, Philippe; Iturbe, Ion; Nicolas, Barbara; Virieux, Jean; Mars, Jérôme I

    2011-09-01

    Acoustic tomography in a shallow ultrasonic waveguide is demonstrated at the laboratory scale between two source-receiver arrays. At a 1/1,000 scale, the waveguide represents a 1.1-km-long, 52-m-deep ocean acoustic channel in the kilohertz frequency range. Two coplanar arrays record the transfer matrix in the time domain of the waveguide between each pair of source-receiver transducers. A time-domain, double-beamforming algorithm is simultaneously performed on the source and receiver arrays that projects the multi-reflected acoustic echoes into an equivalent set of eigenrays, which are characterized by their travel times and their launch and arrival angles. Travel-time differences are measured for each eigenray every 0.1 s when a thermal plume is generated at a given location in the waveguide. Travel-time tomography inversion is then performed using two forward models based either on ray theory or on the diffraction-based sensitivity kernel. The spatially resolved range and depth inversion data confirm the feasibility of acoustic tomography in shallow water. Comparisons are made between inversion results at 1 and 3 MHz with the inversion procedure using ray theory or the finite-frequency approach. The influence of surface fluctuations at the air-water interface is shown and discussed in the framework of shallow-water ocean tomography. © 2011 Acoustical Society of America

  18. Self-spectral calibration for spectral domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Xianling; Gao, Wanrong; Bian, Haiyi; Chen, Chaoliang; Liao, Jiuling

    2013-06-01

    A different real-time self-wavelength calibration method for spectral domain optical coherence tomography is presented in which interference spectra measured from two arbitrary points on the tissue surface are used for calibration. The method takes advantages of two favorable conditions of optical coherence tomography (OCT) signal. First, the signal back-scattered from the tissue surface is generally much stronger than that from positions in the tissue interior, so the spectral component of the surface interference could be extracted from the measured spectrum. Second, the tissue surface is not a plane and a phase difference exists between the light reflected from two different points on the surface. Compared with the zero-crossing automatic method, the introduced method has the advantage of removing the error due to dispersion mismatch or the common phase error. The method is tested experimentally to demonstrate the improved signal-to-noise ratio, higher axial resolution, and slower sensitivity degradation with depth when compared to the use of the zero-crossing method and applied to two-dimensional cross-sectional images of human finger skin.

  19. Role of post-mapping computed tomography in virtual-assisted lung mapping.

    PubMed

    Sato, Masaaki; Nagayama, Kazuhiro; Kuwano, Hideki; Nitadori, Jun-Ichi; Anraku, Masaki; Nakajima, Jun

    2017-02-01

    Background Virtual-assisted lung mapping is a novel bronchoscopic preoperative lung marking technique in which virtual bronchoscopy is used to predict the locations of multiple dye markings. Post-mapping computed tomography is performed to confirm the locations of the actual markings. This study aimed to examine the accuracy of marking locations predicted by virtual bronchoscopy and elucidate the role of post-mapping computed tomography. Methods Automated and manual virtual bronchoscopy was used to predict marking locations. After bronchoscopic dye marking under local anesthesia, computed tomography was performed to confirm the actual marking locations before surgery. Discrepancies between marking locations predicted by the different methods and the actual markings were examined on computed tomography images. Forty-three markings in 11 patients were analyzed. Results The average difference between the predicted and actual marking locations was 30 mm. There was no significant difference between the latest version of the automated virtual bronchoscopy system (30.7 ± 17.2 mm) and manual virtual bronchoscopy (29.8 ± 19.1 mm). The difference was significantly greater in the upper vs. lower lobes (37.1 ± 20.1 vs. 23.0 ± 6.8 mm, for automated virtual bronchoscopy; p < 0.01). Despite this discrepancy, all targeted lesions were successfully resected using 3-dimensional image guidance based on post-mapping computed tomography reflecting the actual marking locations. Conclusions Markings predicted by virtual bronchoscopy were dislocated from the actual markings by an average of 3 cm. However, surgery was accurately performed using post-mapping computed tomography guidance, demonstrating the indispensable role of post-mapping computed tomography in virtual-assisted lung mapping.

  20. Influence of Different Antioxidants on X-Ray Induced DNA Double-Strand Breaks (DSBs) Using γ-H2AX Immunofluorescence Microscopy in a Preliminary Study

    PubMed Central

    Brand, Michael; Sommer, Matthias; Ellmann, Stephan; Wuest, Wolfgang; May, Matthias S.; Eller, Achim; Vogt, Sabine; Lell, Michael M.; Kuefner, Michael A.; Uder, Michael

    2015-01-01

    Background Radiation exposure occurs in X-ray guided interventional procedures or computed tomography (CT) and γ-H2AX-foci are recognized to represent DNA double-strand breaks (DSBs) as a biomarker for radiation induced damage. Antioxidants may reduce the induction of γ-H2AX-foci by binding free radicals. The aim of this study was to establish a dose-effect relationship and a time-effect relationship for the individual antioxidants on DSBs in human blood lymphocytes. Materials and Methods Blood samples from volunteers were irradiated with 10 mGy before and after pre-incubation with different antioxidants (zinc, trolox, lipoic acid, ß-carotene, selenium, vitamin E, vitamin C, N-acetyl-L-cysteine (NAC) and Q 10). Thereby, different pre-incubation times, concentrations and combinations of drugs were evaluated. For assessment of DSBs, lymphocytes were stained against the phosphorylated histone variant γ-H2AX. Results For zinc, trolox and lipoic acid regardless of concentration or pre-incubation time, no significant decrease of γ-H2AX-foci was found. However, ß-carotene (15%), selenium (14%), vitamin E (12%), vitamin C (25%), NAC (43%) and Q 10 (18%) led to a significant reduction of γ-H2AX-foci at a pre-incubation time of 1 hour. The combination of different antioxidants did not have an additive effect. Conclusion Antioxidants administered prior to irradiation demonstrated the potential to reduce γ-H2AX-foci in blood lymphocytes. PMID:25996998

  1. Improving lateral resolution and image quality of optical coherence tomography by the multi-frame superresolution technique for 3D tissue imaging

    PubMed Central

    Shen, Kai; Lu, Hui; Baig, Sarfaraz; Wang, Michael R.

    2017-01-01

    The multi-frame superresolution technique is introduced to significantly improve the lateral resolution and image quality of spectral domain optical coherence tomography (SD-OCT). Using several sets of low resolution C-scan 3D images with lateral sub-spot-spacing shifts on different sets, the multi-frame superresolution processing of these sets at each depth layer reconstructs a higher resolution and quality lateral image. Layer by layer processing yields an overall high lateral resolution and quality 3D image. In theory, the superresolution processing including deconvolution can solve the diffraction limit, lateral scan density and background noise problems together. In experiment, the improved lateral resolution by ~3 times reaching 7.81 µm and 2.19 µm using sample arm optics of 0.015 and 0.05 numerical aperture respectively as well as doubling the image quality has been confirmed by imaging a known resolution test target. Improved lateral resolution on in vitro skin C-scan images has been demonstrated. For in vivo 3D SD-OCT imaging of human skin, fingerprint and retina layer, we used the multi-modal volume registration method to effectively estimate the lateral image shifts among different C-scans due to random minor unintended live body motion. Further processing of these images generated high lateral resolution 3D images as well as high quality B-scan images of these in vivo tissues. PMID:29188089

  2. Achromatic registration of quadrature components of the optical spectrum in spectral domain optical coherence tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shilyagin, P A; Gelikonov, G V; Gelikonov, V M

    2014-07-31

    We have thoroughly investigated the method of simultaneous reception of spectral components with the achromatised quadrature phase shift between two portions of a reference wave, designed for the effective suppression of the 'mirror' artefact in the resulting image obtained by means of spectral domain optical coherence tomography (SD OCT). We have developed and experimentally tested a phase-shifting element consisting of a beam divider, which splits the reference optical beam into the two beams, and of delay lines being individual for each beam, which create a mutual phase difference of π/2 in the double pass of the reference beam. The phasemore » shift achromatism over a wide spectral range is achieved by using in the delay lines the individual elements with different dispersion characteristics. The ranges of admissible adjustment parameters of the achromatised delay line are estimated for exact and inexact conformity of the geometric characteristics of its components to those calculated. A possibility of simultaneous recording of the close-to-quadrature spectral components with a single linear photodetector element is experimentally confirmed. The suppression of the artefact mirror peak in the OCT-signal by an additional 9 dB relative to the level of its suppression is experimentally achieved when the air delay line is used. Two-dimensional images of the surface positioned at an angle to the axis of the probe beam are obtained with the correction of the 'mirror' artefact while maintaining the dynamic range of the image. (laser biophotonics)« less

  3. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    NASA Astrophysics Data System (ADS)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.

  4. Complementary use of optical coherence tomography and 5-aminolevulinic acid induced fluorescent spectroscopy for diagnosis of neoplastic processes in cervix and vulva

    NASA Astrophysics Data System (ADS)

    Sapozhnikova, Veronika V.; Shakhova, Natalia M.; Kamensky, Vladislav A.; Kuranov, Roman V.; Loshenov, Victor B.; Petrova, Svetlana A.

    2003-07-01

    A new approach to improving the diagnostic value of optical methods is suggested, which is based on a complementary investigation of different optical parameters of biotissues. The aim of this paper is comparative study of the feasibility of two optical methods - fluorescence spectroscopy and optical coherence tomography - for visualization of borders of neoplastic processes in the uterine cervix and vulva. Fluorescence spectroscopy is based on the detection of biochemical and optical coherence tomography on backscattering properties in norm and pathological changes of tissues. By means of these optical methods changes in biochemical and morphological properties of tissues were investigated. A parallel analysis of these two optical methods and histology from the center of tumors and their optical borders was made. Thirteen female patients with neoplastic changes in uterine cervix and vulva were enrolled in this study. The borders of the tumor determined by optical methods (fluorescence spectroscopy and optical coherence tomography) are coinciding with the biopsy proved ones. In addition, OCT and fluorescence borders of tumor in the uterine cervix and vulva exceeds colposcopically detectable borders, the averaging difference 2 mm. In future optical methods would considerably enhance diagnostic accuracy of conventional methods used in oncogynecology.

  5. Pre-coding method and apparatus for multiple source or time-shifted single source data and corresponding inverse post-decoding method and apparatus

    NASA Technical Reports Server (NTRS)

    Yeh, Pen-Shu (Inventor)

    1997-01-01

    A pre-coding method and device for improving data compression performance by removing correlation between a first original data set and a second original data set, each having M members, respectively. The pre-coding method produces a compression-efficiency-enhancing double-difference data set. The method and device produce a double-difference data set, i.e., an adjacent-delta calculation performed on a cross-delta data set or a cross-delta calculation performed on two adjacent-delta data sets, from either one of (1) two adjacent spectral bands coming from two discrete sources, respectively, or (2) two time-shifted data sets coming from a single source. The resulting double-difference data set is then coded using either a distortionless data encoding scheme (entropy encoding) or a lossy data compression scheme. Also, a post-decoding method and device for recovering a second original data set having been represented by such a double-difference data set.

  6. Pre-coding method and apparatus for multiple source or time-shifted single source data and corresponding inverse post-decoding method and apparatus

    NASA Technical Reports Server (NTRS)

    Yeh, Pen-Shu (Inventor)

    1998-01-01

    A pre-coding method and device for improving data compression performance by removing correlation between a first original data set and a second original data set, each having M members, respectively. The pre-coding method produces a compression-efficiency-enhancing double-difference data set. The method and device produce a double-difference data set, i.e., an adjacent-delta calculation performed on a cross-delta data set or a cross-delta calculation performed on two adjacent-delta data sets, from either one of (1) two adjacent spectral bands coming from two discrete sources, respectively, or (2) two time-shifted data sets coming from a single source. The resulting double-difference data set is then coded using either a distortionless data encoding scheme (entropy encoding) or a lossy data compression scheme. Also, a post-decoding method and device for recovering a second original data set having been represented by such a double-difference data set.

  7. Source Repeatability of Time-Lapse Offset VSP Surveys for Monitoring CO2 Injection

    NASA Astrophysics Data System (ADS)

    Zhang, Z.; Huang, L.; Rutledge, J. T.; Denli, H.; Zhang, H.; McPherson, B. J.; Grigg, R.

    2009-12-01

    Time-lapse vertical seismic profiling (VSP) surveys have the potential to remotely track the migration of injected CO2 within a geologic formation. To accurately detect small changes due to CO2 injection, the sources of time-lapse VSP surveys must be located exactly at the same positions. However, in practice, the source locations can vary from one survey to another survey. Our numerical simulations demonstrate that a variation of a few meters in the VSP source locations can result in significant changes in time-lapse seismograms. To address the source repeatability issue, we apply double-difference tomography to downgoing waves of time-lapse offset VSP data to invert for the source locations and the velocity structures simultaneously. In collaboration with Resolute Natural Resources, Navajo National Oil and Gas Company, and the Southwest Regional Partnership on Carbon Sequestration under the support of the U.S. Department of Energy’s National Energy Technology Laboratory, one baseline and two repeat offset VSP datasets were acquired in 2007-2009 for monitoring CO2 injection at the Aneth oil field in Utah. A cemented geophone string was used to acquire the data for one zero-offset and seven offset source locations. During the data acquisition, there was some uncertainty in the repeatability of the source locations relative to the baseline survey. Our double-difference tomography results of the Aneth time-lapse VSP data show that the source locations for different surveys are separated up to a few meters. Accounting for these source location variations during VSP data analysis will improve reliability of time-lapse VSP monitoring.

  8. Double-blind, placebo-controlled, multiple-ascending-dose study on the pharmacodynamics of ABIO-08/01, a new CNS drug with potential anxiolytic activity. 2. EEG-tomography findings based on LORETA (low-resolution brain electromagnetic tomography).

    PubMed

    Saletu, Bernd; Anderer, Peter; Wolzt, Michael; Nosiska, Dorothea; Assandri, Alessandro; Noseda, Emanuele; Nannipieri, Fabrizio; Saletu-Zyhlarz, Gerda M

    2009-01-01

    Effects of ABIO-08/01, a new potentially anxiolytic isoxazoline, on regional electrical brain generators were investigated by 3-dimensional EEG tomography. In a double- blind, placebo-controlled, multiple-ascending-dose study, 16 healthy males (30.2 +/- 5.7 years) received 3 oral drug doses (10, 20, 40 mg) and placebo for 7 days (8-day wash-out) in a randomized non-balanced design for phase-1 studies. A 3-min vigilance-controlled (V) EEG, a 4-min resting (R) EEG with eyes closed, a 1-min eyes-open (EO) EEG and psychometric tests were performed 0, 1 and 6 h after taking the drug on days 1 and 5. Low-resolution brain electromagnetic tomography (LORETA) was computed from the spectrally analyzed EEG data, and differences between drug and placebo were displayed as statistical parametric maps. Data were registered to the Talairach-Tournoux Human Brain Atlas available as a digitized MRI. An overall omnibus significance test followed by a voxel-by-voxel t test demonstrated significant regional EEG changes after ABIO-08/01 versus placebo, dependent on recording condition, dose and time. While in the EO-EEG specifically the lowest dose of ABIO-08/01 induced pronounced sedative effects (delta/theta and beta increase) 1 h after acute and slightly less so after superimposed administration, in the 6th hour a decrease in alpha and beta activity signaled less sedative and more relaxant action. In the V-EEG these changes were less pronounced, in the R-EEG partly opposite. Hemisphere-specific changes were observed, suggesting increases in LORETA power over the left temporal, parietal, superior frontal regions and decreases over the right prefrontal, temporal pole and occipital regions. These LORETA changes are discussed in the light of neuroimaging findings on anxiety and anxiolytics. 2009 S. Karger AG, Basel.

  9. Radar attenuation tomography using the centroid frequency downshift method

    USGS Publications Warehouse

    Liu, L.; Lane, J.W.; Quan, Y.

    1998-01-01

    A method for tomographically estimating electromagnetic (EM) wave attenuation based on analysis of centroid frequency downshift (CFDS) of impulse radar signals is described and applied to cross-hole radar data. The method is based on a constant-Q model, which assumes a linear frequency dependence of attenuation for EM wave propagation above the transition frequency. The method uses the CFDS to construct the projection function. In comparison with other methods for estimating attenuation, the CFDS method is relatively insensitive to the effects of geometric spreading, instrument response, and antenna coupling and radiation pattern, but requires the data to be broadband so that the frequency shift and variance can be easily measured. The method is well-suited for difference tomography experiments using electrically conductive tracers. The CFDS method was tested using cross-hole radar data collected at the U.S. Geological Survey Fractured Rock Research Site at Mirror Lake, New Hampshire (NH) during a saline-tracer injection experiment. The attenuation-difference tomogram created with the CFDS method outlines the spatial distribution of saline tracer within the tomography plane. ?? 1998 Elsevier Science B.V. All rights reserved.

  10. Volume moiré tomography based on projection extraction by spatial phase shifting of double crossed gratings

    NASA Astrophysics Data System (ADS)

    Wang, Jia; Guo, Zhenyan; Song, Yang; Han, Jun

    2018-01-01

    To realize volume moiré tomography (VMT) for the real three-dimensional (3D) diagnosis of combustion fields, according to 3D filtered back projection (FBP) reconstruction algorithm, the radial derivatives of the projected phase should be measured firstly. In this paper, a simple spatial phase-shifting moiré deflectometry with double cross gratings is presented to measure the radial first-order derivative of the projected phase. Based on scalar diffraction theory, the explicit analytical intensity distributions of moiré patterns on different diffracted orders are derived, and the spatial shifting characteristics are analyzed. The results indicate that the first-order derivatives of the projected phase in two mutually perpendicular directions are involved in moiré patterns, which can be combined to compute the radial first-order derivative. And multiple spatial phase-shifted moiré patterns can be simultaneously obtained; the phase-shifted values are determined by the parameters of the system. A four-step phase-shifting algorithm is proposed for phase extraction, and its accuracy is proved by numerical simulations. Finally, the moiré deflectometry is used to measure the radial first-order derivative of projected phase of a propane flame with plane incident wave, and the 3D temperature distribution is reconstructed.

  11. Recovery and normalization of triple coincidences in PET.

    PubMed

    Lage, Eduardo; Parot, Vicente; Moore, Stephen C; Sitek, Arkadiusz; Udías, Jose M; Dave, Shivang R; Park, Mi-Ae; Vaquero, Juan J; Herraiz, Joaquin L

    2015-03-01

    Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. To recover triple coincidences, the authors' method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. The addition of triple-coincidence events with the authors' method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.

  12. A fast rebinning algorithm for 3D positron emission tomography using John's equation

    NASA Astrophysics Data System (ADS)

    Defrise, Michel; Liu, Xuan

    1999-08-01

    Volume imaging in positron emission tomography (PET) requires the inversion of the three-dimensional (3D) x-ray transform. The usual solution to this problem is based on 3D filtered-backprojection (FBP), but is slow. Alternative methods have been proposed which factor the 3D data into independent 2D data sets corresponding to the 2D Radon transforms of a stack of parallel slices. Each slice is then reconstructed using 2D FBP. These so-called rebinning methods are numerically efficient but are approximate. In this paper a new exact rebinning method is derived by exploiting the fact that the 3D x-ray transform of a function is the solution to the second-order partial differential equation first studied by John. The method is proposed for two sampling schemes, one corresponding to a pair of infinite plane detectors and another one corresponding to a cylindrical multi-ring PET scanner. The new FORE-J algorithm has been implemented for this latter geometry and was compared with the approximate Fourier rebinning algorithm FORE and with another exact rebinning algorithm, FOREX. Results with simulated data demonstrate a significant improvement in accuracy compared to FORE, while the reconstruction time is doubled. Compared to FOREX, the FORE-J algorithm is slightly less accurate but more than three times faster.

  13. Rostral Anterior Cingulate Cortex Theta Current Density and Response to Antidepressants and Placebo in Major Depression

    PubMed Central

    Korb, Alexander S.; Hunter, Aimee M.; Cook, Ian A.; Leuchter, Andrew F.

    2009-01-01

    Objective To assess whether pretreatment theta current density in the rostral anterior cingulate (rACC) and medial orbitofrontal cortex (mOFC) differentiates responders from non-responders to antidepressant medication or placebo in a double-blinded study. Methods Pretreatment EEGs were collected from 72 subjects with Major Depressive Disorder (MDD) who participated in one of three placebo-controlled trials. Subjects were randomized to receive treatment with fluoxetine, venlafaxine, or placebo. Low-resolution brain electromagnetic tomography (LORETA) was used to assess theta current density in the rACC and mOFC. Results Medication responders showed elevated rACC and mOFC theta current density compared to medication non-responders (rACC: p=0.042; mOFC: p=0.039). There was no significant difference in either brain region between placebo responders and placebo non-responders. Conclusions Theta current density in the rACC and mOFC may be useful as a biomarker for prediction of response to antidepressant medication. Significance This is the first double-blinded treatment study to examine pretreatment rACC and mOFC theta current density in relation to antidepressant response and placebo response. Results support the potential clinical utility of this approach for predicting clinical outcome to antidepressant treatments in MDD. PMID:19539524

  14. Computed tomography landmark-based semi-automated mesh morphing and mapping techniques: generation of patient specific models of the human pelvis without segmentation.

    PubMed

    Salo, Zoryana; Beek, Maarten; Wright, David; Whyne, Cari Marisa

    2015-04-13

    Current methods for the development of pelvic finite element (FE) models generally are based upon specimen specific computed tomography (CT) data. This approach has traditionally required segmentation of CT data sets, which is time consuming and necessitates high levels of user intervention due to the complex pelvic anatomy. The purpose of this research was to develop and assess CT landmark-based semi-automated mesh morphing and mapping techniques to aid the generation and mechanical analysis of specimen-specific FE models of the pelvis without the need for segmentation. A specimen-specific pelvic FE model (source) was created using traditional segmentation methods and morphed onto a CT scan of a different (target) pelvis using a landmark-based method. The morphed model was then refined through mesh mapping by moving the nodes to the bone boundary. A second target model was created using traditional segmentation techniques. CT intensity based material properties were assigned to the morphed/mapped model and to the traditionally segmented target models. Models were analyzed to evaluate their geometric concurrency and strain patterns. Strains generated in a double-leg stance configuration were compared to experimental strain gauge data generated from the same target cadaver pelvis. CT landmark-based morphing and mapping techniques were efficiently applied to create a geometrically multifaceted specimen-specific pelvic FE model, which was similar to the traditionally segmented target model and better replicated the experimental strain results (R(2)=0.873). This study has shown that mesh morphing and mapping represents an efficient validated approach for pelvic FE model generation without the need for segmentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Review of inversion techniques using analysis of different tests

    NASA Astrophysics Data System (ADS)

    Smaglichenko, T. A.

    2012-04-01

    Tomographic techniques are tools, which estimate the Earth's deep interior by inverting seismic data. Reliability of visualization provides adequate understanding of geodynamic processes for prediction of natural hazard and protection of environment. This presentation focuses on two interrelated factors, which affect on the reliability namely: particularities of geophysical medium and strategy for choice of inversion method. Three main techniques are under review. First, the standard LSQR algorithm is derived directly by the Lanczos algebraic application. The Double Difference tomography widely incorporates this algorithm and its expansion. Next, the CSSA technique, or method of subtraction has been introduced into seismology by Nikolaev et al. in 1985. This method got farther development in 2003 (Smaglichenko et al.) as the coordinate method of possible directions, which has been already known in the theory of numerical methods. And finally, the new Differentiated Approach (DA) tomography that has been recently developed by the author for seismology and introduced into applied mathematics as the modification of Gaussian elimination. Different test models are presented by detecting various properties of the medium and having a value for the mining sector as well for prediction of seismic activity. They are: 1) checker-board resolution test; 2) the single anomalous block surrounded by an uniform zone; 3) the large-size structure; 4) the most complicated case, when the model consist of contrast layers and the observation response is equal zero value. The geometry of experiment for all models is given in the note of Leveque et al., 1993. It was assumed that errors in experimental data are in limits of pre-assigned accuracy. The testing showed that LSQR is effective, when the small-size structure (1) is retrieved, while CSSA works faster under reconstruction of the separated anomaly (2). The large-size structure (3) can be reconstructed applying DA, which uses both Lanczos's method and CSSA as composed parts of the inversion process. Difficulty of the model of contrast layers (4) can be overcome with a priori information that could allow the DA implementation. The testing leads us to the following conclusion. Careful analyze and weighted assumptions about characteristics of the being investigated medium should be done before start of data inversion. The choice of suitable technique will provide reliability of solution. Nevertheless, DA is preferred in the case of noisy and large data.

  16. Non-invasive imaging of skin cancer with fluorescence lifetime imaging using two photon tomography

    NASA Astrophysics Data System (ADS)

    Patalay, Rakesh; Talbot, Clifford; Alexandrov, Yuriy; Munro, Ian; Breunig, Hans Georg; König, Karsten; Warren, Sean; Neil, Mark A. A.; French, Paul M. W.; Chu, Anthony; Stamp, Gordon W.; Dunsby, Christopher

    2011-07-01

    Multispectral fluorescence lifetime imaging (FLIM) using two photon microscopy as a non-invasive technique for the diagnosis of skin lesions is described. Skin contains fluorophores including elastin, keratin, collagen, FAD and NADH. This endogenous contrast allows tissue to be imaged without the addition of exogenous agents and allows the in vivo state of cells and tissues to be studied. A modified DermaInspect® multiphoton tomography system was used to excite autofluorescence at 760 nm in vivo and on freshly excised ex vivo tissue. This instrument simultaneously acquires fluorescence lifetime images in four spectral channels between 360-655 nm using time-correlated single photon counting and can also provide hyperspectral images. The multispectral fluorescence lifetime images were spatially segmented and binned to determine lifetimes for each cell by fitting to a double exponential lifetime model. A comparative analysis between the cellular lifetimes from different diagnoses demonstrates significant diagnostic potential.

  17. Trends in optical coherence tomography applied to medical imaging

    NASA Astrophysics Data System (ADS)

    Podoleanu, Adrian G.

    2014-01-01

    The number of publications on optical coherence tomography (OCT) continues to double every three years. Traditionally applied to imaging the eye, OCT is now being extended to fields outside ophthalmology and optometry. Widening its applicability, progress in the core engine of the technology, and impact on development of novel optical sources, make OCT a very active and rapidly evolving field. Trends in the developments of different specific devices, such as optical sources, optical configurations and signal processing will be presented. Encompassing studies on both the configurations as well as on signal processing themes, current research in Kent looks at combining spectral domain with time domain imaging for long axial range and simultaneous imaging at several depths. Results of the collaborative work of the Applied Optics Group in Kent with organisers of this conference will be presented, with reference to 3D monitoring of abfraction.

  18. Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector Using Non-invasive Laser, Optical and X-ray Techniques

    NASA Technical Reports Server (NTRS)

    Radke, C. R.; Meyer, T. R.

    2014-01-01

    The spray characteristics of a liquid-liquid double swirl coaxial injector were studied using non-invasive optical, laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler interferometry was used to characterize droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, X-ray radiography allowed for investigation of sheet thickness and breakup length to be quantified for different recess exit diameters and inlet pressures. Finally, computed tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

  19. Effect of Injector Geometry on Atomization of a Liquid-Liquid Double Swirl Coaxial Injector using Non-Invasive Laser, Optical and X-ray Techniques

    NASA Technical Reports Server (NTRS)

    Radke, C. R.; Meyer, T. R.

    2014-01-01

    The spray characteristics of a Liquid-Liquid Double Swirl Coaxial Injector were studied using noninvasive Optical, Laser, and X-ray diagnostics. A parametric study of injector exit geometry demonstrated that spray breakup time, breakup type and sheet stability could be controlled with exit geometry. Phase Doppler Particle Analysis characterized droplet statistics and non-dimensional droplet parameters over a range of inlet conditions and for various fluids allowing for a study on the role of specific fluid properties in atomization. Further, x-ray radiographs allowed for investigations of sheet thickness and breakup length to be quantified for different recess exits and inlet pressures. Finally Computed Tomography scans revealed that the spray cone was distinctively non-uniform and comprised of several pockets of increased mass flux.

  20. Probing the structure of a caldera for geothermal assessment using enhanced passive seismic tomography. The example of the Campi Flregrei (Italy).

    NASA Astrophysics Data System (ADS)

    Calo, M.; Tramelli, A.; Troise, C.; de Natale, G.

    2015-12-01

    Campi Flegrei (southern Italy) is one of the most studied calderas of the world due to its geothermal potential that was exploited since Romans' age, and its eruption and seismic risk, affecting a densely populated region. The caldera is marked by strong vertical deformations of the soil called bradyseisms, which are often accompanied by seismic crises. In particular the bradyseismic crises of 1982-84 are remembered for the large number of earthquakes that exceeded 16000 events recorded. Seismicity has been used to model the distribution of the elastic parameters with the aim to study the volcano behavior. However, till now seismic velocity models, calculated with standard tomography, failed in resolving small structures (<1.5-2km) located also at shallow depth, which could be responsible of small eruption as the last one that originated the Monte Nuovo monogenic cone in 1538. Here we show Vp and Vp/Vs models carried out by applying an enhanced seismic tomography that uses the Double Difference method (DD, Zhang and Thurber, 2003) complemented with the Weighted Average Model post-processing (WAM, Calò et al., 2009, Calò et al., 2011, 2013). The 3D models obtained with this procedure benefit of the high resolving power due to DD method, which uses both absolute and differential data, and of the improved reliability offered by WAM, which allows to overcome the drawbacks of the standard inversion methods. Our approach allowed to image structures with linear dimension of 0.5-1.2km, resulting in an improvement of the resolving power at least two times of the other published models (e.g. Priolo et al., 2012). Results show small bodies of high Vp and Vp/Vs at shallow depth (2.5-3.5 km) that could be associated either with magmatic intrusions or fluid saturated rocks, probably responsible of unrest episodes. At shallower depth (0.5-2.0 km), the Vp/Vs model is able to discern between water- and gas- bearing regions giving insight on the assessment of the potential of the geothermal reservoir.

  1. A framework for directional and higher-order reconstruction in photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Boink, Yoeri E.; Lagerwerf, Marinus J.; Steenbergen, Wiendelt; van Gils, Stephan A.; Manohar, Srirang; Brune, Christoph

    2018-02-01

    Photoacoustic tomography is a hybrid imaging technique that combines high optical tissue contrast with high ultrasound resolution. Direct reconstruction methods such as filtered back-projection, time reversal and least squares suffer from curved line artefacts and blurring, especially in the case of limited angles or strong noise. In recent years, there has been great interest in regularised iterative methods. These methods employ prior knowledge of the image to provide higher quality reconstructions. However, easy comparisons between regularisers and their properties are limited, since many tomography implementations heavily rely on the specific regulariser chosen. To overcome this bottleneck, we present a modular reconstruction framework for photoacoustic tomography, which enables easy comparisons between regularisers with different properties, e.g. nonlinear, higher-order or directional. We solve the underlying minimisation problem with an efficient first-order primal-dual algorithm. Convergence rates are optimised by choosing an operator-dependent preconditioning strategy. A variety of reconstruction methods are tested on challenging 2D synthetic and experimental data sets. They outperform direct reconstruction approaches for strong noise levels and limited angle measurements, offering immediate benefits in terms of acquisition time and quality. This work provides a basic platform for the investigation of future advanced regularisation methods in photoacoustic tomography.

  2. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler.

    PubMed

    Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E; Boudoux, Caroline

    2015-04-01

    Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett's esophagus.

  3. Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler

    PubMed Central

    Beaudette, Kathy; Baac, Hyoung Won; Madore, Wendy-Julie; Villiger, Martin; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline

    2015-01-01

    Double-clad fiber (DCF) is herein used in conjunction with a double-clad fiber coupler (DCFC) to enable simultaneous and co-registered optical coherence tomography (OCT) and laser tissue coagulation. The DCF allows a single channel fiber-optic probe to be shared: i.e. the core propagating the OCT signal while the inner cladding delivers the coagulation laser light. We herein present a novel DCFC designed and built to combine both signals within a DCF (>90% of single-mode transmission; >65% multimode coupling). Potential OCT imaging degradation mechanisms are also investigated and solutions to mitigate them are presented. The combined DCFC-based system was used to induce coagulation of an ex vivo swine esophagus allowing a real-time assessment of thermal dynamic processes. We therefore demonstrate a DCFC-based system combining OCT imaging with laser coagulation through a single fiber, thus enabling both modalities to be performed simultaneously and in a co-registered manner. Such a system enables endoscopic image-guided laser marking of superficial epithelial tissues or laser thermal therapy of epithelial lesions in pathologies such as Barrett’s esophagus. PMID:25909013

  4. [EEG source localization using LORETA (low resolution electromagnetic tomography)].

    PubMed

    Puskás, Szilvia

    2011-03-30

    Eledctroencephalography (EEG) has excellent temporal resolution, but the spatial resolution is poor. Different source localization methods exist to solve the so-called inverse problem, thus increasing the accuracy of spatial localization. This paper provides an overview of the history of source localization and the main categories of techniques are discussed. LORETA (low resolution electromagnetic tomography) is introduced in details: technical informations are discussed and localization properties of LORETA method are compared to other inverse solutions. Validation of the method with different imaging techniques is also discussed. This paper reviews several publications using LORETA both in healthy persons and persons with different neurological and psychiatric diseases. Finally future possible applications are discussed.

  5. Single and double acquisition strategies for compensation of artifacts from eddy current and transient oscillation in balanced steady-state free precession.

    PubMed

    Lee, Hyun-Soo; Choi, Seung Hong; Park, Sung-Hong

    2017-07-01

    To develop single and double acquisition methods to compensate for artifacts from eddy currents and transient oscillations in balanced steady-state free precession (bSSFP) with centric phase-encoding (PE) order for magnetization-prepared bSSFP imaging. A single and four different double acquisition methods were developed and evaluated with Bloch equation simulations, phantom/in vivo experiments, and quantitative analyses. For the single acquisition method, multiple PE groups, each of which was composed of N linearly changing PE lines, were ordered in a pseudocentric manner for optimal contrast and minimal signal fluctuations. Double acquisition methods used complex averaging of two images that had opposite artifact patterns from different acquisition orders or from different numbers of dummy scans. Simulation results showed high sensitivity of eddy-current and transient-oscillation artifacts to off-resonance frequency and PE schemes. The artifacts were reduced with the PE-grouping with N values from 3 to 8, similar to or better than the conventional pairing scheme of N = 2. The proposed double acquisition methods removed the remaining artifacts significantly. The proposed methods conserved detailed structures in magnetization transfer imaging well, compared with the conventional methods. The proposed single and double acquisition methods can be useful for artifact-free magnetization-prepared bSSFP imaging with desired contrast and minimized dummy scans. Magn Reson Med 78:254-263, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. imaging volcanos with gravity and muon tomography measurements

    NASA Astrophysics Data System (ADS)

    Jourde, Kevin; Gibert, Dominique; Marteau, Jacques; Deroussi, Sébastien; Dufour, Fabrice; de Bremond d'Ars, Jean; Ianigro, Jean-Christophe; Gardien, Serge; Girerd, Claude

    2015-04-01

    Both muon tomography and gravimetry are geohysical methods that provide information on the density structure of the Earth's subsurface. Muon tomography measures the natural flux of cosmic muons and its attenuation produced by the screening effect of the rock mass to image. Gravimetry generally consists in measurements of the vertical component of the local gravity field. Both methods are linearly linked to density, but their spatial sensitivity is very different. Muon tomography essentially works like medical X-ray scan and integrates density information along elongated narrow conical volumes while gravimetry measurements are linked to density by a 3-dimensional integral encompassing the whole studied domain. We show that gravity data are almost useless to constrain the density structure in regions sampled by more than two muon tomography acquisitions. Interestingly the resolution in deeper regions not sampled by muon tomography is significantly improved by joining the two techniques. Examples taken from field experiments performed on La Soufrière of Guadeloupe volcano are discussed.

  7. Quantitative X-ray fluorescence computed tomography for low-Z samples using an iterative absorption correction algorithm

    NASA Astrophysics Data System (ADS)

    Huang, Rong; Limburg, Karin; Rohtla, Mehis

    2017-05-01

    X-ray fluorescence computed tomography is often used to measure trace element distributions within low-Z samples, using algorithms capable of X-ray absorption correction when sample self-absorption is not negligible. Its reconstruction is more complicated compared to transmission tomography, and therefore not widely used. We describe in this paper a very practical iterative method that uses widely available transmission tomography reconstruction software for fluorescence tomography. With this method, sample self-absorption can be corrected not only for the absorption within the measured layer but also for the absorption by material beyond that layer. By combining tomography with analysis for scanning X-ray fluorescence microscopy, absolute concentrations of trace elements can be obtained. By using widely shared software, we not only minimized the coding, took advantage of computing efficiency of fast Fourier transform in transmission tomography software, but also thereby accessed well-developed data processing tools coming with well-known and reliable software packages. The convergence of the iterations was also carefully studied for fluorescence of different attenuation lengths. As an example, fish eye lenses could provide valuable information about fish life-history and endured environmental conditions. Given the lens's spherical shape and sometimes the short distance from sample to detector for detecting low concentration trace elements, its tomography data are affected by absorption related to material beyond the measured layer but can be reconstructed well with our method. Fish eye lens tomography results are compared with sliced lens 2D fluorescence mapping with good agreement, and with tomography providing better spatial resolution.

  8. Evaluation of Macular Ganglion Cell Complex and Peripapillary Retinal Nerve Fiber Layer in Primary Craniopharyngioma by Fourier-Domain Optical Coherence Tomography.

    PubMed

    Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun

    2016-07-03

    BACKGROUND The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. MATERIAL AND METHODS Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. RESULTS The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). CONCLUSIONS GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients.

  9. Evaluation of Macular Ganglion Cell Complex and Peripapillary Retinal Nerve Fiber Layer in Primary Craniopharyngioma by Fourier-Domain Optical Coherence Tomography

    PubMed Central

    Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun

    2016-01-01

    Background The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. Material/Methods Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. Results The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). Conclusions GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients. PMID:27372909

  10. Multidetector computed tomography shows reverse cardiac remodeling after double lung transplantation for pulmonary hypertension.

    PubMed

    Mandich Crovetto, D; Alonso Charterina, S; Jiménez López-Guarch, C; Pont Vilalta, M; Pérez Núñez, M; de Pablo Gafas, A; Escribano Subías, P

    2016-01-01

    To use multidetector computed tomography (MDCT) to evaluate the structural changes in the right heart and pulmonary arteries that occur in patients with severe pulmonary hypertension treated by double lung transplantation. This was a retrospective study of 21 consecutive patients diagnosed with severe pulmonary hypertension who underwent double lung transplantation at our center between 2010 and 2014. We analyzed the last MDCT study done before lung transplantation and the first MDCT study done after lung transplantation. We recorded the following variables: diameter of the pulmonary artery trunk, ratio of the diameter of the pulmonary artery trunk to the diameter of the ascending aorta, diameter of the right ventricle, ratio of the diameter of the left ventricle to the diameter of the right ventricle, and eccentricity index. Statistical analysis consisted of the comparison of the means of the variables recorded. In all cases analyzed, the MDCT study done a mean of 24±14 days after double lung transplantation showed a significant reduction in the size of the right heart chambers, with improved indices of ventricular interdependency index, and reduction in the size of the pulmonary artery trunk (p<0.001 for all the variables analyzed). Patients with pulmonary hypertension treated by double lung transplantation present early reverse remodeling of the changes in the structures of the right heart and pulmonary arterial tree. MDCT is useful for detecting these changes. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Quantification of dental prostheses on cone‐beam CT images by the Taguchi method

    PubMed Central

    Kuo, Rong‐Fu; Fang, Kwang‐Ming; TY, Wong

    2016-01-01

    The gray values accuracy of dental cone‐beam computed tomography (CBCT) is affected by dental metal prostheses. The distortion of dental CBCT gray values could lead to inaccuracies of orthodontic and implant treatment. The aim of this study was to quantify the effect of scanning parameters and dental metal prostheses on the accuracy of dental cone‐beam computed tomography (CBCT) gray values using the Taguchi method. Eight dental model casts of an upper jaw including prostheses, and a ninth prosthesis‐free dental model cast, were scanned by two dental CBCT devices. The mean gray value of the selected circular regions of interest (ROIs) were measured using dental CBCT images of eight dental model casts and were compared with those measured from CBCT images of the prosthesis‐free dental model cast. For each image set, four consecutive slices of gingiva were selected. The seven factors (CBCTs, occlusal plane canting, implant connection, prosthesis position, coping material, coping thickness, and types of dental restoration) were used to evaluate scanning parameter and dental prostheses effects. Statistical methods of signal to noise ratio (S/N) and analysis of variance (ANOVA) with 95% confidence were applied to quantify the effects of scanning parameters and dental prostheses on dental CBCT gray values accuracy. For ROIs surrounding dental prostheses, the accuracy of CBCT gray values were affected primarily by implant connection (42%), followed by type of restoration (29%), prostheses position (19%), coping material (4%), and coping thickness (4%). For a single crown prosthesis (without support of implants) placed in dental model casts, gray value differences for ROIs 1–9 were below 12% and gray value differences for ROIs 13–18 away from prostheses were below 10%. We found the gray value differences set to be between 7% and 8% for regions next to a single implant‐supported titanium prosthesis, and between 46% and 59% for regions between double implant‐supported, nickel‐chromium alloys (Ni‐Cr) prostheses. Quantification of the effect of prostheses and scanning parameters on dental CBCT gray values was assessed. PACS numbers: 87.59.bd, 87.57Q PMID:26894354

  12. The Combination of Diameters of Cricoid Ring and Left Main Bronchus for Selecting the "Best Fit" Double-Lumen Tube.

    PubMed

    Shiqing, Liu; Wenxu, Qi; Jin, Zhang; Youjing, Dong

    2018-04-01

    The aims of this study were to measure diameters of the cricoid ring and left main bronchus in Asian adult patients and to assess the accuracy of double lumen tube size selected according to cricoid and left main bronchus diameter, respectively. Retrospective observational study. Academic, tertiary care hospital. Preoperative CT scans from 87 men and 94 women who had undergone general anesthesia for lung operations. No intervention. The diameters of the cricoid ring and left main bronchus were measured from thoracic computed tomography images after correction of slant. The "best-fit" size of double lumen tube was determined by comparing diameter of the left main bronchus and cricoid ring with the diameter of the double lumen tube. Diameters of the cricoid ring and left main bronchus were both significantly greater in men compared with women (p < 0.0001). Shapes of cricoid rings were different between genders (p < 0.0001), while shapes of the left main bronchus were not significant different (p = 0.343). With reference to the "best fit" size, the rate of agreement of cricoid ring size, left main bronchus size, and height size for men were 100%, 100%, and 94.3%. For women, the rate of agreement of cricoid ring size, left main bronchus size, and height size were 94.7%, 63.8%, and 51.1%. The "best fit" size of a double lumen tube should be decided by a combination of diameters of the cricoid ring and the left main bronchus. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Characteristics of Offshore Hawai';i Island Seismicity and Velocity Structure, including Lo';ihi Submarine Volcano

    NASA Astrophysics Data System (ADS)

    Merz, D. K.; Caplan-Auerbach, J.; Thurber, C. H.

    2013-12-01

    The Island of Hawai';i is home to the most active volcanoes in the Hawaiian Islands. The island's isolated nature, combined with the lack of permanent offshore seismometers, creates difficulties in recording small magnitude earthquakes with accuracy. This background offshore seismicity is crucial in understanding the structure of the lithosphere around the island chain, the stresses on the lithosphere generated by the weight of the islands, and how the volcanoes interact with each other offshore. This study uses the data collected from a 9-month deployment of a temporary ocean bottom seismometer (OBS) network fully surrounding Lo';ihi volcano. This allowed us to widen the aperture of earthquake detection around the Big Island, lower the magnitude detection threshold, and better constrain the hypocentral depths of offshore seismicity that occurs between the OBS network and the Hawaii Volcano Observatory's land based network. Although this study occurred during a time of volcanic quiescence for Lo';ihi, it establishes a basis for background seismicity of the volcano. More than 480 earthquakes were located using the OBS network, incorporating data from the HVO network where possible. Here we present relocated hypocenters using the double-difference earthquake location algorithm HypoDD (Waldhauser & Ellsworth, 2000), as well as tomographic images for a 30 km square area around the summit of Lo';ihi. Illuminated by using the double-difference earthquake location algorithm HypoDD (Waldhauser & Ellsworth, 2000), offshore seismicity during this study is punctuated by events locating in the mantle fault zone 30-50km deep. These events reflect rupture on preexisting faults in the lower lithosphere caused by stresses induced by volcano loading and flexure of the Pacific Plate (Wolfe et al., 2004; Pritchard et al., 2007). Tomography was performed using the double-difference seismic tomography method TomoDD (Zhang & Thurber, 2003) and showed overall velocities to be slower than the regional velocity model (HG50; Klein, 1989) in the shallow lithosphere above 16 km depth. This is likely a result of thick deposits of volcaniclastic sediments and fractured pillow basalts that blanket the southern submarine flank of Mauna Loa, upon which Lo';ihi is currently superimposing (Morgan et al., 2003). A broad, low-velocity anomaly was observed from 20-40 km deep beneath the area of Pahala, and is indicative of the central plume conduit that supplies magma to the active volcanoes. A localized high-velocity body is observed 4-6 km deep beneath Lo';ihi's summit, extending 10 km to the North and South. Oriented approximately parallel to Lo';ihi's active rift zones, this high-velocity body is suggestive of intrusion in the upper crust, similar to Kilauea's high-velocity rift zones.

  14. The Transformation of Enterovirus Replication Structures: a Three-Dimensional Study of Single- and Double-Membrane Compartments

    PubMed Central

    Limpens, Ronald W. A. L.; van der Schaar, Hilde M.; Kumar, Darshan; Koster, Abraham J.; Snijder, Eric J.; van Kuppeveld, Frank J. M.; Bárcena, Montserrat

    2011-01-01

    ABSTRACT All positive-strand RNA viruses induce membrane structures in their host cells which are thought to serve as suitable microenvironments for viral RNA synthesis. The structures induced by enteroviruses, which are members of the family Picornaviridae, have so far been described as either single- or double-membrane vesicles (DMVs). Aside from the number of delimiting membranes, their exact architecture has also remained elusive due to the limitations of conventional electron microscopy. In this study, we used electron tomography (ET) to solve the three-dimensional (3-D) ultrastructure of these compartments. At different time points postinfection, coxsackievirus B3-infected cells were high-pressure frozen and freeze-substituted for ET analysis. The tomograms showed that during the exponential phase of viral RNA synthesis, closed smooth single-membrane tubules constituted the predominant virus-induced membrane structure, with a minor proportion of DMVs that were either closed or connected to the cytosol in a vase-like configuration. As infection progressed, the DMV number steadily increased, while the tubular single-membrane structures gradually disappeared. Late in infection, complex multilamellar structures, previously unreported, became apparent in the cytoplasm. Serial tomography disclosed that their basic unit is a DMV, which is enwrapped by one or multiple cisternae. ET also revealed striking intermediate structures that strongly support the conversion of single-membrane tubules into double-membrane and multilamellar structures by a process of membrane apposition, enwrapping, and fusion. Collectively, our work unravels the sequential appearance of distinct enterovirus-induced replication structures, elucidates their detailed 3-D architecture, and provides the basis for a model for their transformation during the course of infection. PMID:21972238

  15. Randomized, double-blind, placebo-controlled clinical trial on the efficacy of 0.5% indomethacin eye drops in uveitic macular edema.

    PubMed

    Allegri, Pia; Murialdo, Ugo; Peri, Simona; Carniglia, Rosanna; Crivelli, Maria Grazia; Compiano, Silvia; Autuori, Silvia; Mastromarino, Antonio; Zurria, Monia; Marrazzo, Giuseppina

    2014-03-10

    The aim of the present randomized, double-blind, placebo-controlled clinical trial was to assess the efficacy and tolerability of 0.5% indomethacin (INDOM) eye drops in adult patients suffering from macular edema (ME) related to different etiology uveitis. Forty-six eyes of 31 adult patients (20 females and 11 males) mean age 39 years, affected by inflammatory ME, were randomized to receive a dose of commercial 0.5% INDOM eye-drops four times per day (16 subjects = 23 eyes) or placebo (the vehicle of INDOM, 15 subjects = 23 eyes) during a 6-month active therapy follow-up. Study assessment at each visit included visual acuity testing (VA), slit-lamp examination, IOP evaluation, and Heidelberg Spectralis optical coherence tomography (OCT) central foveal thickness (CFT) measurement. Any variation in subjective symptoms and tolerability was also detected. Statistical analysis showed, from baseline to the 6-month visit, a significant reduction in CFT (P < 0.0001) and a significant improvement in VA only in the 0.5% INDOM-treated group; a global reduction of discomfort symptoms was present in both groups (P < 0.001). The four times per day administration of 0.5% INDOM eye drops in eyes affected with uveitic ME from different etiologies, compared with placebo, is associated with a significant reduction in ME at the 6-month follow-up visit, as measured by spectral-domain optical coherence tomography (SD-OCT). However, not all eyes showed a complete resolution of ME because of vitreoretinal traction. (https://eudract.ema.europa.eu/index.html number, EUDRACT 2011-001522-20.).

  16. Recovery and normalization of triple coincidences in PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.

    2015-03-15

    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose amore » simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the authors’ method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Conclusions: Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.« less

  17. Seismic imaging: From classical to adjoint tomography

    NASA Astrophysics Data System (ADS)

    Liu, Q.; Gu, Y. J.

    2012-09-01

    Seismic tomography has been a vital tool in probing the Earth's internal structure and enhancing our knowledge of dynamical processes in the Earth's crust and mantle. While various tomographic techniques differ in data types utilized (e.g., body vs. surface waves), data sensitivity (ray vs. finite-frequency approximations), and choices of model parameterization and regularization, most global mantle tomographic models agree well at long wavelengths, owing to the presence and typical dimensions of cold subducted oceanic lithospheres and hot, ascending mantle plumes (e.g., in central Pacific and Africa). Structures at relatively small length scales remain controversial, though, as will be discussed in this paper, they are becoming increasingly resolvable with the fast expanding global and regional seismic networks and improved forward modeling and inversion techniques. This review paper aims to provide an overview of classical tomography methods, key debates pertaining to the resolution of mantle tomographic models, as well as to highlight recent theoretical and computational advances in forward-modeling methods that spearheaded the developments in accurate computation of sensitivity kernels and adjoint tomography. The first part of the paper is devoted to traditional traveltime and waveform tomography. While these approaches established a firm foundation for global and regional seismic tomography, data coverage and the use of approximate sensitivity kernels remained as key limiting factors in the resolution of the targeted structures. In comparison to classical tomography, adjoint tomography takes advantage of full 3D numerical simulations in forward modeling and, in many ways, revolutionizes the seismic imaging of heterogeneous structures with strong velocity contrasts. For this reason, this review provides details of the implementation, resolution and potential challenges of adjoint tomography. Further discussions of techniques that are presently popular in seismic array analysis, such as noise correlation functions, receiver functions, inverse scattering imaging, and the adaptation of adjoint tomography to these different datasets highlight the promising future of seismic tomography.

  18. Using of electrical impedance tomography for diagnostics of the cervix uteri diseases

    NASA Astrophysics Data System (ADS)

    Trokhanova, O. V.; Chijova, Y. A.; Okhapkin, M. B.; Korjenevsky, A. V.; Tuykin, T. S.

    2010-04-01

    The report presents results of investigation of the neck of the womb (cervix) of 64 women aged from 19 to 70, that formed 4 clinical groups (1st group: 15 women without any pathology of the cervix, 2nd group: 27 women with the erosion, 3rd group: 11 women with dysplasia, 4th group: 11 women with cancer of the cervix). The aim of this research is to assess the capabilities of electrical impedance tomography in the diagnostics of the cervix diseases. The methods of the research were: visual examination with the speculum, colposcopy, and biopsy of the cervix. Also the new method of visualization of the cervix was used - electrical impedance tomography with the help of gynecological impedance tomograph (GIT). The following results were obtained. The electrical conductivity of the cervix in norm and in different pathology has different indices, which allow differential diagnostics of benign and malignant diseases. Summary: the method of electrical impedance tomography allows not only visually estimate portio vaginalis, but receive indices of electrical conductivity of the cervix on the depth up to 0.8 cm and thereby reveal pathological changes in epithelium without invasive and operative intervention.

  19. Towards combined optical coherence tomography and hyper-spectral imaging for gastrointestinal endoscopy

    NASA Astrophysics Data System (ADS)

    Attendu, Xavier; Crunelle, Camille; de Sivry-Houle, Martin Poinsinet; Maubois, Billie; Urbain, Joanie; Turrell, Chloe; Strupler, Mathias; Godbout, Nicolas; Boudoux, Caroline

    2018-04-01

    Previous works have demonstrated feasibility of combining optical coherence tomography (OCT) and hyper-spectral imaging (HSI) through a single double-clad fiber (DCF). In this proceeding we present the continued development of a system combining both modalities and capable of rapid imaging. We discuss the development of a rapidly scanning, dual-band, polygonal swept-source system which combines NIR (1260-1340 nm) and visible (450-800 nm) wavelengths. The NIR band is used for OCT imaging while visible light allows HSI. Scanning rates up to 24 kHz are reported. Furthermore, we present and discuss the fiber system used for light transport, delivery and collection, and the custom signal acquisition software. Key points include the use of a double-clad fiber coupler as well as important alignments and back-reflection management. Simultaneous and co-registered imaging with both modalities is presented in a bench-top system

  20. Molecular imaging needles: dual-modality optical coherence tomography and fluorescence imaging of labeled antibodies deep in tissue

    PubMed Central

    Scolaro, Loretta; Lorenser, Dirk; Madore, Wendy-Julie; Kirk, Rodney W.; Kramer, Anne S.; Yeoh, George C.; Godbout, Nicolas; Sampson, David D.; Boudoux, Caroline; McLaughlin, Robert A.

    2015-01-01

    Molecular imaging using optical techniques provides insight into disease at the cellular level. In this paper, we report on a novel dual-modality probe capable of performing molecular imaging by combining simultaneous three-dimensional optical coherence tomography (OCT) and two-dimensional fluorescence imaging in a hypodermic needle. The probe, referred to as a molecular imaging (MI) needle, may be inserted tens of millimeters into tissue. The MI needle utilizes double-clad fiber to carry both imaging modalities, and is interfaced to a 1310-nm OCT system and a fluorescence imaging subsystem using an asymmetrical double-clad fiber coupler customized to achieve high fluorescence collection efficiency. We present, to the best of our knowledge, the first dual-modality OCT and fluorescence needle probe with sufficient sensitivity to image fluorescently labeled antibodies. Such probes enable high-resolution molecular imaging deep within tissue. PMID:26137379

  1. The Effect of Three Methods of Supporting the Double Bass on Muscle Tension.

    ERIC Educational Resources Information Center

    Dennis, Allan

    1984-01-01

    Using different methods of holding the double bass, college students performed Beethoven's Symphony No. 9. Audio recordings of performance were rated. Muscle tension readings from the left arm, right arm, upper back, and lower back were taken, using electromyography. Results suggest nonsignificant differences in both performance quality and muscle…

  2. Comparison of light and x-ray sensitometric responses of double-emulsion films for different processing conditions.

    PubMed

    Blendl, C; Buhr, E

    2001-12-01

    The effects of different film processing conditions on light and x-ray sensitometric responses were compared for a variety of double-emulsion x-ray films. The processing conditions were altered by changes of the developer temperature. Three different exposure variants were applied: x-ray sensitometry using two stepped neutral density attenuators between film and screens, simultaneous double-sided light sensitometry, and single-sided light sensitometry. 13 different types of double-emulsion x-ray films were investigated, among them three asymmetric films. In the special case of exposing the asymmetric films with the single-sided light sensitometer, a method was investigated where each side of the film is exposed at different locations and the sum effect is analyzed. From each sensitometric curve shape two parameters, the logarithmic speed (logS) and the average gradient (G), were evaluated. The results of this study can be summarized as follows: (1) Single-sided and double-sided light sensitometers revealed almost equal changes of logS when the processing conditions are altered. Thus, single-sided light sensitometers can serve as a substitute for double-sided light sensitometers provided that suited exposure methods are used and appropriate sensitometric parameters are evaluated. (2) Light sensitometry quantitatively indicated changes of the film processing that affect the x-ray speed. Hence, light sensitometry is a useful method to monitor changes in film processing.

  3. Quantum control and process tomography of a semiconductor quantum dot hybrid qubit.

    PubMed

    Kim, Dohun; Shi, Zhan; Simmons, C B; Ward, D R; Prance, J R; Koh, Teck Seng; Gamble, John King; Savage, D E; Lagally, M G; Friesen, Mark; Coppersmith, S N; Eriksson, Mark A

    2014-07-03

    The similarities between gated quantum dots and the transistors in modern microelectronics--in fabrication methods, physical structure and voltage scales for manipulation--have led to great interest in the development of quantum bits (qubits) in semiconductor quantum dots. Although quantum dot spin qubits have demonstrated long coherence times, their manipulation is often slower than desired for important future applications, such as factoring. Furthermore, scalability and manufacturability are enhanced when qubits are as simple as possible. Previous work has increased the speed of spin qubit rotations by making use of integrated micromagnets, dynamic pumping of nuclear spins or the addition of a third quantum dot. Here we demonstrate a qubit that is a hybrid of spin and charge. It is simple, requiring neither nuclear-state preparation nor micromagnets. Unlike previous double-dot qubits, the hybrid qubit enables fast rotations about two axes of the Bloch sphere. We demonstrate full control on the Bloch sphere with π-rotation times of less than 100 picoseconds in two orthogonal directions, which is more than an order of magnitude faster than any other double-dot qubit. The speed arises from the qubit's charge-like characteristics, and its spin-like features result in resistance to decoherence over a wide range of gate voltages. We achieve full process tomography in our electrically controlled semiconductor quantum dot qubit, extracting high fidelities of 85 per cent for X rotations (transitions between qubit states) and 94 per cent for Z rotations (phase accumulation between qubit states).

  4. A double-blind, randomized, placebo-controlled trial of itopride (100 and 200 mg three times daily) on gastric motor and sensory function in healthy volunteers.

    PubMed

    Choung, R S; Talley, N J; Peterson, J; Camilleri, M; Burton, D; Harmsen, W S; Zinsmeister, A R

    2007-03-01

    Itopride, a dopamine D2 antagonist and acetylcholinesterase inhibitor, significantly improved symptoms in patients with functional dyspepsia in one phase II randomized trial. However, the mechanisms by which itopride may improve symptoms are unknown. We aimed to compare the effects of two doses of itopride and placebo on gastric volumes, gastric emptying, small bowel transit and satiation in female and male healthy volunteers. Randomized, double-blind, placebo-controlled study evaluated gastric function before and after 7 days of itopride 100 mg (n = 16) or 200 mg (n = 15) or placebo (n = 15) t.i.d. Validated methods were used to study gastric accommodation (single photon emission computed tomography), gastric emptying and orocecal transit and satiation postnutrient challenge. The three arms were comparable with regard to age, gender and body mass index. There were no statistically significant effects of itopride on gastric emptying, orocecal transit, fasting gastric volume, maximum tolerated volume or aggregate symptom score with nutrient drink challenge. Postprandial (PP) change in gastric volume differed in the three groups (P = 0.019): 625[+/-28 (SEM)], 555(+/-26) and 512(+/-33) in placebo, itopride 100 and 200 mg groups, respectively. In healthy subjects, itopride reduced total PP gastric volume without accelerating gastric emptying or significantly altering gastric motor and sensory function in healthy individuals.

  5. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair

    PubMed Central

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-01-01

    Context: Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. Objective: To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Data Sources: Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. Study Selection: The literature was systematically searched, and 5 level I and II studies were found comparing clinical outcomes of single-row and double-row rotator cuff repair. Coleman methodology scores were calculated for each article. Data Extraction: Meta-analysis was performed, with treatment effect between single row and double row for clinical outcomes and with odds ratios for radiographic results. The sample size necessary to detect a given difference in clinical outcome between the 2 methods was calculated. Results: Three level I studies had Coleman scores of 80, 74, and 81, and two level II studies had scores of 78 and 73. There were 156 patients with single-row repairs and 147 patients with double-row repairs, both with an average follow-up of 23 months (range, 12-40 months). Double-row repairs resulted in a greater treatment effect for each validated outcome measure in 4 studies, but the differences were not clinically or statistically significant (range, 0.4-2.2 points; 95% confidence interval, –0.19, 4.68 points). Double-row repairs had better radiographic results, but the differences were also not statistically significant (P = 0.13). Two studies had adequate power to detect a 10-point difference between repair methods using the Constant score, and 1 study had power to detect a 5-point difference using the UCLA (University of California, Los Angeles) score. Conclusions: Double-row rotator cuff repair does not show a statistically significant improvement in clinical outcome or radiographic healing with short-term follow-up. PMID:23016017

  6. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair.

    PubMed

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-05-01

    Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. The literature was systematically searched, and 5 level I and II studies were found comparing clinical outcomes of single-row and double-row rotator cuff repair. Coleman methodology scores were calculated for each article. Meta-analysis was performed, with treatment effect between single row and double row for clinical outcomes and with odds ratios for radiographic results. The sample size necessary to detect a given difference in clinical outcome between the 2 methods was calculated. Three level I studies had Coleman scores of 80, 74, and 81, and two level II studies had scores of 78 and 73. There were 156 patients with single-row repairs and 147 patients with double-row repairs, both with an average follow-up of 23 months (range, 12-40 months). Double-row repairs resulted in a greater treatment effect for each validated outcome measure in 4 studies, but the differences were not clinically or statistically significant (range, 0.4-2.2 points; 95% confidence interval, -0.19, 4.68 points). Double-row repairs had better radiographic results, but the differences were also not statistically significant (P = 0.13). Two studies had adequate power to detect a 10-point difference between repair methods using the Constant score, and 1 study had power to detect a 5-point difference using the UCLA (University of California, Los Angeles) score. Double-row rotator cuff repair does not show a statistically significant improvement in clinical outcome or radiographic healing with short-term follow-up.

  7. Double lung point in an 18-month-old child: a case report and literature review

    PubMed Central

    2015-01-01

    Objective Double lung point is a rare sign of pneumothorax in clinical practice. In this report I presented an 18-month-old child who presented with bilateral pneumothorax. Data synthesis and case presentation Ultrasonography examination revealed conventional lung point sign on the right and double lung point on the left side. Thoracentesis was attempted and closed thoracic drainage was performed on the right side, but no gas was drawn on the left side. Clinical implication of double lung point sign found in chest ultrasonography is that the size of pneumothorax is limited and conservative treatment is enough. Conclusions To the best of our knowledge, this is the first case of double lung point identified with ultrasonography in child. The strength of the case is that the double lung point sign is supported by computed tomography (CT). Furthermore, we propose that the presence of double lung point indicates limited pneumothorax and conservative management may well be attempted. PMID:25922750

  8. Correlative multiple porosimetries for reservoir sandstones with adoption of a new reference-sample-guided computed-tomographic method.

    PubMed

    Jin, Jae Hwa; Kim, Junho; Lee, Jeong-Yil; Oh, Young Min

    2016-07-22

    One of the main interests in petroleum geology and reservoir engineering is to quantify the porosity of reservoir beds as accurately as possible. A variety of direct measurements, including methods of mercury intrusion, helium injection and petrographic image analysis, have been developed; however, their application frequently yields equivocal results because these methods are different in theoretical bases, means of measurement, and causes of measurement errors. Here, we present a set of porosities measured in Berea Sandstone samples by the multiple methods, in particular with adoption of a new method using computed tomography and reference samples. The multiple porosimetric data show a marked correlativeness among different methods, suggesting that these methods are compatible with each other. The new method of reference-sample-guided computed tomography is more effective than the previous methods when the accompanied merits such as experimental conveniences are taken into account.

  9. Correlative multiple porosimetries for reservoir sandstones with adoption of a new reference-sample-guided computed-tomographic method

    PubMed Central

    Jin, Jae Hwa; Kim, Junho; Lee, Jeong-Yil; Oh, Young Min

    2016-01-01

    One of the main interests in petroleum geology and reservoir engineering is to quantify the porosity of reservoir beds as accurately as possible. A variety of direct measurements, including methods of mercury intrusion, helium injection and petrographic image analysis, have been developed; however, their application frequently yields equivocal results because these methods are different in theoretical bases, means of measurement, and causes of measurement errors. Here, we present a set of porosities measured in Berea Sandstone samples by the multiple methods, in particular with adoption of a new method using computed tomography and reference samples. The multiple porosimetric data show a marked correlativeness among different methods, suggesting that these methods are compatible with each other. The new method of reference-sample-guided computed tomography is more effective than the previous methods when the accompanied merits such as experimental conveniences are taken into account. PMID:27445105

  10. Electromagnetic Navigational Bronchoscopy Reduces the Time Required for Localization and Resection of Lung Nodules.

    PubMed

    Bolton, William David; Cochran, Thomas; Ben-Or, Sharon; Stephenson, James E; Ellis, William; Hale, Allyson L; Binks, Andrew P

    The aims of the study were to evaluate electromagnetic navigational bronchoscopy (ENB) and computed tomography-guided placement as localization techniques for minimally invasive resection of small pulmonary nodules and determine whether electromagnetic navigational bronchoscopy is a safer and more effective method than computed tomography-guided localization. We performed a retrospective review of our thoracic surgery database to identify patients who underwent minimally invasive resection for a pulmonary mass and used either electromagnetic navigational bronchoscopy or computed tomography-guided localization techniques between July 2011 and May 2015. Three hundred eighty-three patients had a minimally invasive resection during our study period, 117 of whom underwent electromagnetic navigational bronchoscopy or computed tomography localization (electromagnetic navigational bronchoscopy = 81; computed tomography = 36). There was no significant difference between computed tomography and electromagnetic navigational bronchoscopy patient groups with regard to age, sex, race, pathology, nodule size, or location. Both computed tomography and electromagnetic navigational bronchoscopy were 100% successful at localizing the mass, and there was no difference in the type of definitive surgical resection (wedge, segmentectomy, or lobectomy) (P = 0.320). Postoperative complications occurred in 36% of all patients, but there were no complications related to the localization procedures. In terms of localization time and surgical time, there was no difference between groups. However, the down/wait time between localization and resection was significant (computed tomography = 189 minutes; electromagnetic navigational bronchoscopy = 27 minutes); this explains why the difference in total time (sum of localization, down, and surgery) was significant (P < 0.001). We found electromagnetic navigational bronchoscopy to be as safe and effective as computed tomography-guided wire placement and to provide a significantly decreased down time between localization and surgical resection.

  11. Phase Tomography Reconstructed by 3D TIE in Hard X-ray Microscope

    NASA Astrophysics Data System (ADS)

    Yin, Gung-Chian; Chen, Fu-Rong; Pyun, Ahram; Je, Jung Ho; Hwu, Yeukuang; Liang, Keng S.

    2007-01-01

    X-ray phase tomography and phase imaging are promising ways of investigation on low Z material. A polymer blend of PE/PS sample was used to test the 3D phase retrieval method in the parallel beam illuminated microscope. Because the polymer sample is thick, the phase retardation is quite mixed and the image can not be distinguished when the 2D transport intensity equation (TIE) is applied. In this study, we have provided a different approach for solving the phase in three dimensions for thick sample. Our method involves integration of 3D TIE/Fourier slice theorem for solving thick phase sample. In our experiment, eight sets of de-focal series image data sets were recorded covering the angular range of 0 to 180 degree. Only three set of image cubes were used in 3D TIE equation for solving the phase tomography. The phase contrast of the polymer blend in 3D is obviously enhanced, and the two different groups of polymer blend can be distinguished in the phase tomography.

  12. A fast cross-validation method for alignment of electron tomography images based on Beer-Lambert law.

    PubMed

    Yan, Rui; Edwards, Thomas J; Pankratz, Logan M; Kuhn, Richard J; Lanman, Jason K; Liu, Jun; Jiang, Wen

    2015-11-01

    In electron tomography, accurate alignment of tilt series is an essential step in attaining high-resolution 3D reconstructions. Nevertheless, quantitative assessment of alignment quality has remained a challenging issue, even though many alignment methods have been reported. Here, we report a fast and accurate method, tomoAlignEval, based on the Beer-Lambert law, for the evaluation of alignment quality. Our method is able to globally estimate the alignment accuracy by measuring the goodness of log-linear relationship of the beam intensity attenuations at different tilt angles. Extensive tests with experimental data demonstrated its robust performance with stained and cryo samples. Our method is not only significantly faster but also more sensitive than measurements of tomogram resolution using Fourier shell correlation method (FSCe/o). From these tests, we also conclude that while current alignment methods are sufficiently accurate for stained samples, inaccurate alignments remain a major limitation for high resolution cryo-electron tomography. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. A fast cross-validation method for alignment of electron tomography images based on Beer-Lambert law

    PubMed Central

    Yan, Rui; Edwards, Thomas J.; Pankratz, Logan M.; Kuhn, Richard J.; Lanman, Jason K.; Liu, Jun; Jiang, Wen

    2015-01-01

    In electron tomography, accurate alignment of tilt series is an essential step in attaining high-resolution 3D reconstructions. Nevertheless, quantitative assessment of alignment quality has remained a challenging issue, even though many alignment methods have been reported. Here, we report a fast and accurate method, tomoAlignEval, based on the Beer-Lambert law, for the evaluation of alignment quality. Our method is able to globally estimate the alignment accuracy by measuring the goodness of log-linear relationship of the beam intensity attenuations at different tilt angles. Extensive tests with experimental data demonstrated its robust performance with stained and cryo samples. Our method is not only significantly faster but also more sensitive than measurements of tomogram resolution using Fourier shell correlation method (FSCe/o). From these tests, we also conclude that while current alignment methods are sufficiently accurate for stained samples, inaccurate alignments remain a major limitation for high resolution cryo-electron tomography. PMID:26455556

  14. Automated tumour boundary delineation on 18F-FDG PET images using active contour coupled with shifted-optimal thresholding method

    NASA Astrophysics Data System (ADS)

    Khamwan, Kitiwat; Krisanachinda, Anchali; Pluempitiwiriyawej, Charnchai

    2012-10-01

    This study presents an automatic method to trace the boundary of the tumour in positron emission tomography (PET) images. It has been discovered that Otsu's threshold value is biased when the within-class variances between the object and the background are significantly different. To solve the problem, a double-stage threshold search that minimizes the energy between the first Otsu's threshold and the maximum intensity value is introduced. Such shifted-optimal thresholding is embedded into a region-based active contour so that both algorithms are performed consecutively. The efficiency of the method is validated using six sphere inserts (0.52-26.53 cc volume) of the IEC/2001 torso phantom. Both spheres and phantom were filled with 18F solution with four source-to-background ratio (SBR) measurements of PET images. The results illustrate that the tumour volumes segmented by combined algorithm are of higher accuracy than the traditional active contour. The method had been clinically implemented in ten oesophageal cancer patients. The results are evaluated and compared with the manual tracing by an experienced radiation oncologist. The advantage of the algorithm is the reduced erroneous delineation that improves the precision and accuracy of PET tumour contouring. Moreover, the combined method is robust, independent of the SBR threshold-volume curves, and it does not require prior lesion size measurement.

  15. Correction for specimen movement and rotation errors for in-vivo Optical Projection Tomography

    PubMed Central

    Birk, Udo Jochen; Rieckher, Matthias; Konstantinides, Nikos; Darrell, Alex; Sarasa-Renedo, Ana; Meyer, Heiko; Tavernarakis, Nektarios; Ripoll, Jorge

    2010-01-01

    The application of optical projection tomography to in-vivo experiments is limited by specimen movement during the acquisition. We present a set of mathematical correction methods applied to the acquired data stacks to correct for movement in both directions of the image plane. These methods have been applied to correct experimental data taken from in-vivo optical projection tomography experiments in Caenorhabditis elegans. Successful reconstructions for both fluorescence and white light (absorption) measurements are shown. Since no difference between movement of the animal and movement of the rotation axis is made, this approach at the same time removes artifacts due to mechanical drifts and errors in the assumed center of rotation. PMID:21258448

  16. Precise Hypocenter Determination around Palu Koro Fault: a Preliminary Results

    NASA Astrophysics Data System (ADS)

    Fawzy Ismullah, M. Muhammad; Nugraha, Andri Dian; Ramdhan, Mohamad; Wandono

    2017-04-01

    Sulawesi area is located in complex tectonic pattern. High seismicity activity in the middle of Sulawesi is related to Palu Koro fault (PKF). In this study, we determined precise hypocenter around PKF by applying double-difference method. We attempt to investigate of the seismicity rate, geometry of the fault and distribution of focus depth around PKF. We first re-pick P-and S-wave arrival time of the PKF events to determine the initial hypocenter location using Hypoellipse method through updated 1-D seismic velocity. Later on, we relocated the earthquake event using double-difference method. Our preliminary results show the distribution of relocated events are located around PKF and have smaller residual time than the initial location. We will enhance the hypocenter location through updating of arrival time by applying waveform cross correlation method as input for double-difference relocation.

  17. Positron emission tomography assessment of effects of benzodiazepines on regional glucose metabolic rate in patients with anxiety disorder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buchsbaum, M.S.; Wu, J.; Haier, R.

    1987-06-22

    Patients with generalized anxiety disorder (n = 18) entered a 21-day, double-blind, placebo-controlled random assignment trial of clorazepate. Positron emission tomography with YF-deoxyglucose was carried out before and after treatment. Decreases in glucose metabolic rate in visual cortex and relative increases in the basal ganglia and thalamus were found. A correlation between regional changes in metabolic rate and regional benzodiazepine receptor binding density from other human autopsy studies was observed; brain regions highest in receptor density showed the greatest decrease in rate.

  18. Development and validation of a biologically realistic tissue-mimicking material for photoacoustics and other bimodal optical-acoustic modalities

    NASA Astrophysics Data System (ADS)

    Vogt, William C.; Jia, Congxian; Wear, Keith A.; Garra, Brian S.; Pfefer, T. Joshua

    2017-03-01

    Recent years have seen rapid development of hybrid optical-acoustic imaging modalities with broad applications in research and clinical imaging, including photoacoustic tomography (PAT), photoacoustic microscopy, and ultrasound-modulated optical tomography. Tissue-mimicking phantoms are an important tool for objectively and quantitatively simulating in vivo imaging system performance. However, no standard tissue phantoms exist for such systems. One major challenge is the development of tissue-mimicking materials (TMMs) that are both highly stable and possess biologically realistic properties. To address this need, we have explored the use of various formulations of PVC plastisol (PVCP) based on varying mixtures of several liquid plasticizers. We developed a custom PVCP formulation with optical absorption and scattering coefficients, speed of sound, and acoustic attenuation that are tunable and tissue-relevant. This TMM can simulate different tissue compositions and offers greater mechanical strength than hydrogels. Optical properties of PVCP samples with varying composition were characterized using integrating sphere spectrophotometry and the inverse adding-doubling method. Acoustic properties were determined using a broadband pulse-transmission technique. To demonstrate the utility of this bimodal TMM, we constructed an image quality phantom designed to enable quantitative evaluation of PAT spatial resolution. The phantom was imaged using a custom combined PAT-ultrasound imaging system. Results indicated that this more biologically realistic TMM produced performance trends not captured in simpler liquid phantoms. In the future, this TMM may be broadly utilized for performance evaluation of optical, acoustic, and hybrid optical-acoustic imaging systems.

  19. Efficient sweep buffering in swept source optical coherence tomography using a fast optical switch

    PubMed Central

    Dhalla, Al-Hafeez; Shia, Kevin; Izatt, Joseph A.

    2012-01-01

    We describe a novel buffering technique for increasing the A-scan rate of swept source optical coherence tomography (SSOCT) systems employing low duty cycle swept source lasers. This technique differs from previously reported buffering techniques in that it employs a fast optical switch, capable of switching in 60 ns, instead of a fused fiber coupler at the end of the buffering stage, and is therefore appreciably more power efficient. The use of the switch also eliminates patient exposure to light that is not used for imaging that occurs at the end of the laser sweep, thereby increasing the system sensitivity. We also describe how careful management of polarization can remove undesirable artifacts due to polarization mode dispersion. In addition, we demonstrate how numerical compensation techniques can be used to modify the signal from a Mach-Zehnder interferometer (MZI) clock obtained from the original sweep to recalibrate the buffered sweep, thereby reducing the complexity of systems employing lasers with integrated MZI clocks. Combining these methods, we constructed an SSOCT system employing an Axsun technologies laser with a sweep rate of 100kHz and 6dB imaging range of 5.5mm. The sweep rate was doubled with sweep buffering to 200 kHz, and the imaging depth was extended to 9 mm using coherence revival. We demonstrated the feasibility of this system by acquiring images of the anterior segments and retinas of healthy human volunteers. PMID:23243559

  20. Efficient sweep buffering in swept source optical coherence tomography using a fast optical switch.

    PubMed

    Dhalla, Al-Hafeez; Shia, Kevin; Izatt, Joseph A

    2012-12-01

    We describe a novel buffering technique for increasing the A-scan rate of swept source optical coherence tomography (SSOCT) systems employing low duty cycle swept source lasers. This technique differs from previously reported buffering techniques in that it employs a fast optical switch, capable of switching in 60 ns, instead of a fused fiber coupler at the end of the buffering stage, and is therefore appreciably more power efficient. The use of the switch also eliminates patient exposure to light that is not used for imaging that occurs at the end of the laser sweep, thereby increasing the system sensitivity. We also describe how careful management of polarization can remove undesirable artifacts due to polarization mode dispersion. In addition, we demonstrate how numerical compensation techniques can be used to modify the signal from a Mach-Zehnder interferometer (MZI) clock obtained from the original sweep to recalibrate the buffered sweep, thereby reducing the complexity of systems employing lasers with integrated MZI clocks. Combining these methods, we constructed an SSOCT system employing an Axsun technologies laser with a sweep rate of 100kHz and 6dB imaging range of 5.5mm. The sweep rate was doubled with sweep buffering to 200 kHz, and the imaging depth was extended to 9 mm using coherence revival. We demonstrated the feasibility of this system by acquiring images of the anterior segments and retinas of healthy human volunteers.

  1. 4D electron tomography.

    PubMed

    Kwon, Oh-Hoon; Zewail, Ahmed H

    2010-06-25

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  2. 4D Electron Tomography

    NASA Astrophysics Data System (ADS)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  3. A Comparison of Ultrasound Tomography Methods in Circular Geometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leach, R R; Azevedo, S G; Berryman, J G

    2002-01-24

    Extremely high quality data was acquired using an experimental ultrasound scanner developed at Lawrence Livermore National Laboratory using a 2D ring geometry with up to 720 transmitter/receiver transducer positions. This unique geometry allows reflection and transmission modes and transmission imaging and quantification of a 3D volume using 2D slice data. Standard image reconstruction methods were applied to the data including straight-ray filtered back projection, reflection tomography, and diffraction tomography. Newer approaches were also tested such as full wave, full wave adjoint method, bent-ray filtered back projection, and full-aperture tomography. A variety of data sets were collected including a formalin-fixed humanmore » breast tissue sample, a commercial ultrasound complex breast phantom, and cylindrical objects with and without inclusions. The resulting reconstruction quality of the images ranges from poor to excellent. The method and results of this study are described including like-data reconstructions produced by different algorithms with side-by-side image comparisons. Comparisons to medical B-scan and x-ray CT scan images are also shown. Reconstruction methods with respect to image quality using resolution, noise, and quantitative accuracy, and computational efficiency metrics will also be discussed.« less

  4. Double Gallbladder Originating from Left Hepatic Duct: A Case Report and Review of Literature

    PubMed Central

    Gorecki, Piotr J.; Andrei, Valeriu E; Musacchio, Tito

    1998-01-01

    Background: Double gallbladder is a rare anomaly of the biliary tract. Double gallbladder arising from the left hepatic duct was previously reported only once in the literature. Case Report: A case of symptomatic cholelithiasis in a double gallbladder, diagnosed on preoperative ultrasound, computed tomography (CT) and endoscopic retrograde cholangiopancreatogram (ERCP) is reported. At laparoscopic cholangiography via the accessory gallbladder no accessory cystic duct was visualized. After conversion to open cholecystectomy, the duplicated gallbladder was found to arise directly from the left hepatic duct; it was resected and the duct repaired. Conclusions: We emphasize that a careful intraoperative cholangiographic evaluation of the accessory gallbladder is mandatory in order to prevent inadvertent injury to bile ducts, since a large variety of ductal abnormality may exist. PMID:10036124

  5. Structure of crust and upper mantle beneath NW Himalayas, Pamir and Hindukush by multi-scale double-difference seismic tomography

    NASA Astrophysics Data System (ADS)

    Bhatti, Zahid Imran; Zhao, Junmeng; Khan, Nangyal Ghani; Shah, Syed Tallataf Hussain

    2018-08-01

    The India-Asia collision and subsequent subduction initiated the evolution of major tectonic features in the Western Syntaxis. The complex tectonic structure and shallow to deep seismicity have attracted geoscientists over the past two decades. The present research is based on a 3D tomographic inversion of P-wave arrival time data to constrain the crustal and upper mantle structure beneath the NW Himalayas and Pamir-Hindukush region using the Double-difference tomography. We utilized a very large multi-scale dataset comprising 19,080 earthquakes recorded at 397 local and regional seismic stations from 1950 to 2017. The northward dipping seismic zone coinciding with the low velocity anomaly suggests the subduction of the Indian lower crust beneath the Hindukush. The extent of the northward advancing Indian slab increases from east to west in this region. We observed no signs of northward subduction of the Indian plate under the Hindukush beyond 71°E longitude. The Indian plate overturns due south after interacting with the Asian plate beneath the southern Pamir, which correlates with the counter-clockwise rotation of the Indian plate. The Asian plate is also imaged as a southward subducting seismic zone beneath the southern Pamir. In the NW Himalayas, the northward subducting Indian plate appears as a gently dipping low velocity anomaly beneath the Karakoram Block. The stresses caused by the collision and subduction along the Shyok Suture and Indus Suture are translated to the south. The crustal scale seismicity and high velocity anomalies indicate an intense deformation in the crust, which is manifested by syntaxial bends and thrust faults to the south of the Main Mantle Thrust.

  6. A California statewide three-dimensional seismic velocity model from both absolute and differential times

    USGS Publications Warehouse

    Lin, G.; Thurber, C.H.; Zhang, H.; Hauksson, E.; Shearer, P.M.; Waldhauser, F.; Brocher, T.M.; Hardebeck, J.

    2010-01-01

    We obtain a seismic velocity model of the California crust and uppermost mantle using a regional-scale double-difference tomography algorithm. We begin by using absolute arrival-time picks to solve for a coarse three-dimensional (3D) P velocity (VP) model with a uniform 30 km horizontal node spacing, which we then use as the starting model for a finer-scale inversion using double-difference tomography applied to absolute and differential pick times. For computational reasons, we split the state into 5 subregions with a grid spacing of 10 to 20 km and assemble our final statewide VP model by stitching together these local models. We also solve for a statewide S-wave model using S picks from both the Southern California Seismic Network and USArray, assuming a starting model based on the VP results and a VP=VS ratio of 1.732. Our new model has improved areal coverage compared with previous models, extending 570 km in the SW-NE directionand 1320 km in the NW-SE direction. It also extends to greater depth due to the inclusion of substantial data at large epicentral distances. Our VP model generally agrees with previous separate regional models for northern and southern California, but we also observe some new features, such as high-velocity anomalies at shallow depths in the Klamath Mountains and Mount Shasta area, somewhat slow velocities in the northern Coast Ranges, and slow anomalies beneath the Sierra Nevada at midcrustal and greater depths. This model can be applied to a variety of regional-scale studies in California, such as developing a unified statewide earthquake location catalog and performing regional waveform modeling.

  7. Double-input compartmental modeling and spectral analysis for the quantification of positron emission tomography data in oncology

    NASA Astrophysics Data System (ADS)

    Tomasi, G.; Kimberley, S.; Rosso, L.; Aboagye, E.; Turkheimer, F.

    2012-04-01

    In positron emission tomography (PET) studies involving organs different from the brain, ignoring the metabolite contribution to the tissue time-activity curves (TAC), as in the standard single-input (SI) models, may compromise the accuracy of the estimated parameters. We employed here double-input (DI) compartmental modeling (CM), previously used for [11C]thymidine, and a novel DI spectral analysis (SA) approach on the tracers 5-[18F]fluorouracil (5-[18F]FU) and [18F]fluorothymidine ([18F]FLT). CM and SA were performed initially with a SI approach using the parent plasma TAC as an input function. These methods were then employed using a DI approach with the metabolite plasma TAC as an additional input function. Regions of interest (ROIs) corresponding to healthy liver, kidneys and liver metastases for 5-[18F]FU and to tumor, vertebra and liver for [18F]FLT were analyzed. For 5-[18F]FU, the improvement of the fit quality with the DI approaches was remarkable; in CM, the Akaike information criterion (AIC) always selected the DI over the SI model. Volume of distribution estimates obtained with DI CM and DI SA were in excellent agreement, for both parent 5-[18F]FU (R2 = 0.91) and metabolite [18F]FBAL (R2 = 0.99). For [18F]FLT, the DI methods provided notable improvements but less substantial than for 5-[18F]FU due to the lower rate of metabolism of [18F]FLT. On the basis of the AIC values, agreement between [18F]FLT Ki estimated with the SI and DI models was good (R2 = 0.75) for the ROIs where the metabolite contribution was negligible, indicating that the additional input did not bias the parent tracer only-related estimates. When the AIC suggested a substantial contribution of the metabolite [18F]FLT-glucuronide, on the other hand, the change in the parent tracer only-related parameters was significant (R2 = 0.33 for Ki). Our results indicated that improvements of DI over SI approaches can range from moderate to substantial and are more significant for tracers with a high rate of metabolism. Furthermore, they showed that SA is suitable for DI modeling and can be used effectively in the analysis of PET data.

  8. Study on dynamic deformation synchronized measurement technology of double-layer liquid surfaces

    NASA Astrophysics Data System (ADS)

    Tang, Huiying; Dong, Huimin; Liu, Zhanwei

    2017-11-01

    Accurate measurement of the dynamic deformation of double-layer liquid surfaces plays an important role in many fields, such as fluid mechanics, biomechanics, petrochemical industry and aerospace engineering. It is difficult to measure dynamic deformation of double-layer liquid surfaces synchronously for traditional methods. In this paper, a novel and effective method for full-field static and dynamic deformation measurement of double-layer liquid surfaces has been developed, that is wavefront distortion of double-wavelength transmission light with geometric phase analysis (GPA) method. Double wavelength lattice patterns used here are produced by two techniques, one is by double wavelength laser, and the other is by liquid crystal display (LCD). The techniques combine the characteristics such as high transparency, low reflectivity and fluidity of liquid. Two color lattice patterns produced by laser and LCD were adjusted at a certain angle through the tested double-layer liquid surfaces simultaneously. On the basis of the refractive indexes difference of two transmitted lights, the double-layer liquid surfaces were decoupled with GPA method. Combined with the derived relationship between phase variation of transmission-lattice patterns and out-of plane heights of two surfaces, as well as considering the height curves of the liquid level, the double-layer liquid surfaces can be reconstructed successfully. Compared with the traditional measurement method, the developed method not only has the common advantages of the optical measurement methods, such as high-precision, full-field and non-contact, but also simple, low cost and easy to set up.

  9. Comparison of gravimetric and a double-indicator dilution technique for assessment of extra-vascular lung water in endotoxaemia.

    PubMed

    Rossi, P; Oldner, A; Wanecek, M; Leksell, L G; Rudehill, A; Konrad, D; Weitzberg, E

    2003-03-01

    To compare a molecular double-indicator dilution technique with the gravimetrical reference method for measurement of extra-vascular lung water in porcine endotoxin shock. Open comparative experimental study. Animal research laboratory. In fourteen anaesthetised, mechanically ventilated landrace pigs, central and pulmonary haemodynamics as well as pulmonary gas exchange were measured. Extra-vascular lung water was quantitated gravimetrically as well as with a molecular double indicator dilution technique. Eight of these animals were subjected to endotoxaemia, the rest serving as sham controls. No difference in extra-vascular lung water was observed between the two methods in sham animals. Furthermore, extra-vascular lung water assessed with the molecular double-indicator dilution technique at the initiation of endotoxin infusion did not differ significantly from the corresponding values for sham animals. Endotoxaemia induced a hypodynamic shock with concurrent pulmonary hypertension and a pronounced deterioration in gas exchange. No increase in extra-vascular lung water was detected with the molecular double-indicator dilution technique in response to endotoxin, whereas this parameter was significantly higher when assessed with the gravimetric method. The molecular double-indicator dilution technique showed similar results as the gravimetrical method for assessment of extra-vascular lung water in non-endotoxaemic conditions. However, during endotoxin-induced lung injury the molecular double indicator dilution technique failed to detect the significant increase in extra-vascular lung water as measured by the gravimetric method. These data suggest that the molecular double indicator dilution technique may be of limited value during sepsis-induced lung injury.

  10. Ambient noise adjoint tomography for a linear array in North China

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Yao, H.; Liu, Q.; Yuan, Y. O.; Zhang, P.; Feng, J.; Fang, L.

    2017-12-01

    Ambient noise tomography based on dispersion data and ray theory has been widely utilized for imaging crustal structures. In order to improve the inversion accuracy, ambient noise tomography based on the 3D adjoint approach or full waveform inversion has been developed recently, however, the computational cost is tremendous. In this study we present 2D ambient noise adjoint tomography for a linear array in north China with significant computational efficiency compared to 3D ambient noise adjoint tomography. During the preprocessing, we first convert the observed data in 3D media, i.e., surface-wave empirical Green's functions (EGFs) from ambient noise cross-correlation, to the reconstructed EGFs in 2D media using a 3D/2D transformation scheme. Different from the conventional steps of measuring phase dispersion, the 2D adjoint tomography refines 2D shear wave speeds along the profile directly from the reconstructed Rayleigh wave EGFs in the period band 6-35s. With the 2D initial model extracted from the 3D model from traditional ambient noise tomography, adjoint tomography updates the model by minimizing the frequency-dependent Rayleigh wave traveltime misfits between the reconstructed EGFs and synthetic Green function (SGFs) in 2D media generated by the spectral-element method (SEM), with a preconditioned conjugate gradient method. The multitaper traveltime difference measurement is applied in four period bands during the inversion: 20-35s, 15-30s, 10-20s and 6-15s. The recovered model shows more detailed crustal structures with pronounced low velocity anomaly in the mid-lower crust beneath the junction of Taihang Mountains and Yin-Yan Mountains compared with the initial model. This low velocity structure may imply the possible intense crust-mantle interactions, probably associated with the magmatic underplating during the Mesozoic to Cenozoic evolution of the region. To our knowledge, it's first time that ambient noise adjoint tomography is implemented in 2D media. Considering the intensive computational cost and storage of 3D adjoint tomography, this 2D ambient noise adjoint tomography has potential advantages to get high-resolution 2D crustal structures with limited computational resource.

  11. Excitation-resolved multispectral method for imaging pharmacokinetic parameters in dynamic fluorescent molecular tomography

    NASA Astrophysics Data System (ADS)

    Chen, Maomao; Zhou, Yuan; Su, Han; Zhang, Dong; Luo, Jianwen

    2017-04-01

    Imaging of the pharmacokinetic parameters in dynamic fluorescence molecular tomography (DFMT) can provide three-dimensional metabolic information for biological studies and drug development. However, owing to the ill-posed nature of the FMT inverse problem, the relatively low quality of the parametric images makes it difficult to investigate the different metabolic processes of the fluorescent targets with small distances. An excitation-resolved multispectral DFMT method is proposed; it is based on the fact that the fluorescent targets with different concentrations show different variations in the excitation spectral domain and can be considered independent signal sources. With an independent component analysis method, the spatial locations of different fluorescent targets can be decomposed, and the fluorescent yields of the targets at different time points can be recovered. Therefore, the metabolic process of each component can be independently investigated. Simulations and phantom experiments are carried out to evaluate the performance of the proposed method. The results demonstrated that the proposed excitation-resolved multispectral method can effectively improve the reconstruction accuracy of the parametric images in DFMT.

  12. Effect of object location on the density measurement in cone-beam computed tomography versus multislice computed tomography

    PubMed Central

    Eskandarloo, Amir; Abdinian, Mehrdad; Salemi, Fatemeh; Hashemzadeh, Zahra; Safaei, Mehran

    2012-01-01

    Background: Bone density measurement in a radiographic view is a valuable method for evaluating the density of bone quality before performing some dental procedures such as, dental implant placements. It seems that Cone-Beam Computed Tomography (CBCT) can be used as a diagnostic tool for evaluating the density of the bone, prior to any treatment, as the reported radiation dose in this method is minimal. The aim of this study is to investigate the effect of object location on the density measurement in CBCT versus Multislice computed tomography (CT). Materials and Methods: In an experimental study, three samples with similar dimensions, but different compositions, different densities (Polyethylene, Polyamide, Polyvinyl Chloride), and three bone pieces of different parts of the mandibular bone were imaged in three different positions by CBCT and Multislice CT sets. The average density value was computed for each sample in each position. Then the data obtained from each CBCT was converted to a Hounsfield unit and evaluated using a single variable T analysis. A P value <0.05 was considered to be significant. Results: The density in a Multislice CT is stable in the form of a Hounsfield Number, but this density is variable in the images acquired through CBCT, and the change in the position results in significant changes in the density. In this study, a statistically significant difference (P value = 0.000) has been observed for the position of the sample and its density in CBCT in comparison to Multislice CT. Conclusions: Density values in CBCT are not real because they are affected by the position of the object in the machine. PMID:23814567

  13. Double layer drainage performance of porous asphalt pavement

    NASA Astrophysics Data System (ADS)

    Ji, Yangyang; Xie, Jianguang; Liu, Mingxi

    2018-06-01

    In order to improve the design reliability of the double layer porous asphalt pavement, the 3D seepage finite element method was used to study the drainage capacity of double layer PAC pavements with different geometric parameters. It revealed that the effect of pavement drainage length, slope, permeability coefficient and structure design on the drainage capacity. The research of this paper can provide reference for the design of double layer porous asphalt pavement in different rainfall intensity areas, and provide guides for the related engineering design.

  14. 68Ga-PSMA PET/CT for the detection of bone metastasis in recurrent prostate cancer and a PSA level <2 ng/ml: Two case reports and a literature review

    PubMed Central

    Petersen, Lars J.; Nielsen, Julie B.; Dettmann, Katja; Fisker, Rune V.; Haberkorn, Uwe; Stenholt, Louise; Zacho, Helle D.

    2017-01-01

    Localization of prostate cancer recurrence, particularly in the bones, is a major challenge with standard of care imaging in patients with biochemical recurrence following curatively intended treatment. Gallium-68-labeled prostate specific membrane antigen positron emission tomography/computed tomography (68Ga-PSMA PET/CT) is a novel and promising method for imaging in prostate cancer. The present study reports two cases of patients with prostate cancer with biochemical recurrence, with evidence of bone metastases on 68Ga-PSMA PET/CT images and low prostate specific antigen PSA levels (<2 ng/ml) and PSA doubling time >6 months. The bone metastases were verified by supplementary imaging with 18F-sodium fluoride PET/CT and magnetic resonance imaging as well as biochemical responses to androgen deprivation therapy. Therefore, 68Ga-PSMA PET/CT is promising for the restaging of patients with prostate cancer with biochemical recurrence, including patients with low PSA levels and low PSA kinetics. PMID:28685078

  15. Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source

    NASA Astrophysics Data System (ADS)

    Lim, Yiheng; Yatagai, Toyohiko; Otani, Yukitoshi

    2016-04-01

    An ultra-high resolution spectral domain optical coherence tomography (SD-OCT) was developed using a cost-effective supercontinuum laser. A spectral filter consists of a dispersive prism, a cylindrical lens and a right-angle prism was built to transmit the wavelengths in range 680-940 nm to the OCT system. The SD-OCT has achieved 1.9 μm axial resolution and the sensitivity was estimated to be 91.5 dB. A zero-crossing fringes matching method which maps the wavelengths to the pixel indices of the spectrometer was proposed for the OCT spectral calibration. A double sided foam tape as a static sample and the tip of a middle finger as a biological sample were measured by the OCT. The adhesive and the internal structure of the foam of the tape were successfully visualized in three dimensions. Sweat ducts was clearly observed in the OCT images at very high resolution. To the best of our knowledge, this is the first demonstration of ultra-high resolution visualization of sweat duct by OCT.

  16. En Face Optical Coherence Tomography for Visualization of the Choroid.

    PubMed

    Savastano, Maria Cristina; Rispoli, Marco; Savastano, Alfonso; Lumbroso, Bruno

    2015-05-01

    To assess posterior pole choroid patterns in healthy eyes using en face optical coherence tomography (OCT). This observational study included 154 healthy eyes of 77 patients who underwent en face OCT. The mean age of the patients was 31.2 years (standard deviation: 13 years); 40 patients were women, and 37 patients were men. En face imaging of the choroidal vasculature was assessed using an OCT Optovue RTVue (Optovue, Fremont, CA). To generate an appropriate choroid image, the best detectable vessels in Haller's layer below the retinal pigment epithelium surface parallel plane were selected. Images of diverse choroidal vessel patterns at the posterior pole were observed and recorded with en face OCT. Five different patterns of Haller's layer with different occurrences were assessed. Pattern 1 (temporal herringbone) represented 49.2%, pattern 2 (branched from below) and pattern 3 (laterally diagonal) represented 14.2%, pattern 4 (doubled arcuate) was observed in 11.9%, and pattern 5 (reticular feature) was observed in 10.5% of the reference plane. In vivo assessment of human choroid microvasculature in healthy eyes using en face OCT demonstrated five different patterns. The choroid vasculature pattern may play a role in the origin and development of neuroretinal pathologies, with potential importance in chorioretinal diseases and circulatory abnormalities. Copyright 2015, SLACK Incorporated.

  17. A Double-difference Earthquake location algorithm: Method and application to the Northern Hayward Fault, California

    USGS Publications Warehouse

    Waldhauser, F.; Ellsworth, W.L.

    2000-01-01

    We have developed an efficient method to determine high-resolution hypocenter locations over large distances. The location method incorporates ordinary absolute travel-time measurements and/or cross-correlation P-and S-wave differential travel-time measurements. Residuals between observed and theoretical travel-time differences (or double-differences) are minimized for pairs of earthquakes at each station while linking together all observed event-station pairs. A least-squares solution is found by iteratively adjusting the vector difference between hypocentral pairs. The double-difference algorithm minimizes errors due to unmodeled velocity structure without the use of station corrections. Because catalog and cross-correlation data are combined into one system of equations, interevent distances within multiplets are determined to the accuracy of the cross-correlation data, while the relative locations between multiplets and uncorrelated events are simultaneously determined to the accuracy of the absolute travel-time data. Statistical resampling methods are used to estimate data accuracy and location errors. Uncertainties in double-difference locations are improved by more than an order of magnitude compared to catalog locations. The algorithm is tested, and its performance is demonstrated on two clusters of earthquakes located on the northern Hayward fault, California. There it colapses the diffuse catalog locations into sharp images of seismicity and reveals horizontal lineations of hypocenter that define the narrow regions on the fault where stress is released by brittle failure.

  18. Tomography reconstruction methods for damage diagnosis of wood structure in construction field

    NASA Astrophysics Data System (ADS)

    Qiu, Qiwen; Lau, Denvid

    2018-03-01

    The structural integrity of wood building element plays a critical role in the public safety, which requires effective methods for diagnosis of internal damage inside the wood body. Conventionally, the non-destructive testing (NDT) methods such as X-ray computed tomography, thermography, radar imaging reconstruction method, ultrasonic tomography, nuclear magnetic imaging techniques, and sonic tomography have been used to obtain the information about the internal structure of wood. In this paper, the applications, advantages and disadvantages of these traditional tomography methods are reviewed. Additionally, the present article gives an overview of recently developed tomography approach that relies on the use of mechanical and electromagnetic waves for assessing the structural integrity of wood buildings. This developed tomography reconstruction method is believed to provide a more accurate, reliable, and comprehensive assessment of wood structural integrity

  19. Development of double-pair double difference location algorithm and its application to the regular earthquakes and non-volcanic tremors

    NASA Astrophysics Data System (ADS)

    Guo, H.; Zhang, H.

    2016-12-01

    Relocating high-precision earthquakes is a central task for monitoring earthquakes and studying the structure of earth's interior. The most popular location method is the event-pair double-difference (DD) relative location method, which uses the catalog and/or more accurate waveform cross-correlation (WCC) differential times from event pairs with small inter-event separations to the common stations to reduce the effect of the velocity uncertainties outside the source region. Similarly, Zhang et al. [2010] developed a station-pair DD location method which uses the differential times from common events to pairs of stations to reduce the effect of the velocity uncertainties near the source region, to relocate the non-volcanic tremors (NVT) beneath the San Andreas Fault (SAF). To utilize advantages of both DD location methods, we have proposed and developed a new double-pair DD location method to use the differential times from pairs of events to pairs of stations. The new method can remove the event origin time and station correction terms from the inversion system and cancel out the effects of the velocity uncertainties near and outside the source region simultaneously. We tested and applied the new method on the northern California regular earthquakes to validate its performance. In comparison, among three DD location methods, the new double-pair DD method can determine more accurate relative locations and the station-pair DD method can better improve the absolute locations. Thus, we further proposed a new location strategy combining station-pair and double-pair differential times to determine accurate absolute and relative locations at the same time. For NVTs, it is difficult to pick the first arrivals and derive the WCC event-pair differential times, thus the general practice is to measure station-pair envelope WCC differential times. However, station-pair tremor locations are scattered due to the low-precision relative locations. The ability that double-pair data can be directly constructed from the station-pair data means that double-pair DD method can be used for improving NVT locations. We have applied the new method to the NVTs beneath the SAF near Cholame, California. Compared to the previous results, the new double-pair DD tremor locations are more concentrated and show more detailed structures.

  20. One step linear reconstruction method for continuous wave diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Ukhrowiyah, N.; Yasin, M.

    2017-09-01

    The method one step linear reconstruction method for continuous wave diffuse optical tomography is proposed and demonstrated for polyvinyl chloride based material and breast phantom. Approximation which used in this method is selecting regulation coefficient and evaluating the difference between two states that corresponding to the data acquired without and with a change in optical properties. This method is used to recovery of optical parameters from measured boundary data of light propagation in the object. The research is demonstrated by simulation and experimental data. Numerical object is used to produce simulation data. Chloride based material and breast phantom sample is used to produce experimental data. Comparisons of results between experiment and simulation data are conducted to validate the proposed method. The results of the reconstruction image which is produced by the one step linear reconstruction method show that the image reconstruction almost same as the original object. This approach provides a means of imaging that is sensitive to changes in optical properties, which may be particularly useful for functional imaging used continuous wave diffuse optical tomography of early diagnosis of breast cancer.

  1. Correction of nonuniformity error of Gafchromic EBT2 and EBT3.

    PubMed

    Katsuda, Toshizo; Gotanda, Rumi; Gotanda, Tatsuhiro; Akagawa, Takuya; Tanki, Nobuyoshi; Kuwano, Tadao; Yabunaka, Kouichi

    2016-05-08

    This study investigates an X-ray dose measurement method for computed tomography using Gafchromic films. Nonuniformity of the active layer is a major problem in Gafchromic films. In radiotherapy, nonuniformity error is reduced by applying the double-exposure technique, but this is impractical in diagnostic radiology because of the heel effect. Therefore, we propose replacing the X-rays in the double-exposure technique with ultraviolet (UV)-A irradiation of Gafchromic EBT2 and EBT3. To improve the reproducibility of the scan position, Gafchromic EBT2 and EBT3 films were attached to a 3-mm-thick acrylic plate. The samples were then irradiated with a 10 W UV-A fluorescent lamp placed at a distance of 72cm for 30, 60, and 90 minutes. The profile curves were evaluated along the long and short axes of the film center, and the standard deviations of the pixel values were calculated over large areas of the films. Paired t-test was performed. UV-A irradiation exerted a significant effect on Gafchromic EBT2 (paired t-test; p = 0.0275) but not on EBT3 (paired t-test; p = 0.2785). Similarly, the homogeneity was improved in Gafchromic EBT2 but not in EBT3. Therefore, the double-exposure technique under UV-A irradiation is suitable only for EBT2 films.

  2. Integration of Geophysical Methods By A Generalised Probability Tomography Approach

    NASA Astrophysics Data System (ADS)

    Mauriello, P.; Patella, D.

    In modern science, the propensity interpretative approach stands on the assumption that any physical system consists of two kinds of reality: actual and potential. Also geophysical data systems have potentialities that extend far beyond the few actual models normally attributed to them. Indeed, any geophysical data set is in itself quite inherently ambiguous. Classical deterministic inversion, including tomography, usu- ally forces a measured data set to collapse into a few rather subjective models based on some available a priori information. Classical interpretation is thus an intrinsically limited approach requiring a very deep logical extension. We think that a way to high- light a system full potentiality is to introduce probability as the leading paradigm in dealing with field data systems. Probability tomography has been recently introduced as a completely new approach to data interpretation. Probability tomography has been originally formulated for the self-potential method. It has been then extended to geo- electric, natural source electromagnetic induction, gravity and magnetic methods. Fol- lowing the same rationale, in this paper we generalize the probability tomography the- ory to a generic geophysical anomaly vector field, including the treatment for scalar fields as a particular case. This generalization makes then possible to address for the first time the problem of the integration of different methods by a conjoint probabil- ity tomography imaging procedure. The aim is to infer the existence of an unknown buried object through the analysis of an ad hoc occurrence probability function, blend- ing the physical messages brought forth by a set of singularly observed anomalies.

  3. Seismic velocity structure of the incoming Pacific Plate subducting into the central part of the Japan Trench revealed by traveltime tomography using OBS data

    NASA Astrophysics Data System (ADS)

    Obana, K.; Fujie, G.; Kodaira, S.; Takahashi, T.; Yamamoto, Y.; Miura, S.; Shinohara, M.

    2016-12-01

    Subduction of oceanic plates plays an important role in the water transportation from the earth surface into the deep mantle. Recent active seismic survey studies succeed to image that the seismic velocities within the oceanic crust and the uppermost mantle in the outer rise region decreases toward the trench axis. These velocity changes are considered as an indication of the hydration and alteration of the incoming oceanic plates prior to the subduction. However, the area with sufficient resolution of the active seismic studies is often limited at depths corresponding to the oceanic crust and several km beneath the oceanic Moho. In this study, we have examined the seismic velocity structure of the incoming/subducting Pacific Plate beneath the trench axis and outer trench-slope of the central part of the Japan Trench. The seismicity in the Pacific Plate, including several M7-class intra-plate earthquakes, has been active since the 2011 Tohoku-Oki earthquake in the study area. These activities were observed by the ocean bottom seismographs (OBS) deployed repeatedly. The data obtained from these OBS observations allow us to resolve the seismic velocity structures at greater depths compared to the active seismic surveys. We conducted 3-D traveltime tomography by using double-difference tomography method (Zhang and Thurber, 2003). The results show that the seismic velocities within the oceanic mantle decreased toward the trench axis. The velocity reduction begins at about 80 km seaward of the trench axis and extended to a depth of at least 30 km beneath the trench axis area. If the observed P-wave velocity reduction from 8.4 km/s to 7.7 km/s at a depth of 15 km below the oceanic Moho is caused by the serpentinization of the oceanic mantle (Carlson and Miller, 2003), roughly 2.5 weight per cent of water is expected in the low velocity anomalies in the oceanic mantle.

  4. Midstory hardwood species respond differently to chainsaw girdle method and herbicide treatment

    Treesearch

    Ronald A. Rathfon; Michael R. Saunders

    2013-01-01

    Foresters in the Central Hardwoods Region commonly fell or girdle interfering trees and apply herbicide to the cut surface when performing intermediate silvicultural treatments. The objective of this study was to compare the use of single and double chainsaw girdle methods in combination with a herbicide treatment and, within the double girdle method, compare herbicide...

  5. Atom probe trajectory mapping using experimental tip shape measurements.

    PubMed

    Haley, D; Petersen, T; Ringer, S P; Smith, G D W

    2011-11-01

    Atom probe tomography is an accurate analytical and imaging technique which can reconstruct the complex structure and composition of a specimen in three dimensions. Despite providing locally high spatial resolution, atom probe tomography suffers from global distortions due to a complex projection function between the specimen and detector which is different for each experiment and can change during a single run. To aid characterization of this projection function, this work demonstrates a method for the reverse projection of ions from an arbitrary projection surface in 3D space back to an atom probe tomography specimen surface. Experimental data from transmission electron microscopy tilt tomography are combined with point cloud surface reconstruction algorithms and finite element modelling to generate a mapping back to the original tip surface in a physically and experimentally motivated manner. As a case study, aluminium tips are imaged using transmission electron microscopy before and after atom probe tomography, and the specimen profiles used as input in surface reconstruction methods. This reconstruction method is a general procedure that can be used to generate mappings between a selected surface and a known tip shape using numerical solutions to the electrostatic equation, with quantitative solutions to the projection problem readily achievable in tens of minutes on a contemporary workstation. © 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.

  6. Coupled double-distribution-function lattice Boltzmann method for the compressible Navier-Stokes equations.

    PubMed

    Li, Q; He, Y L; Wang, Y; Tao, W Q

    2007-11-01

    A coupled double-distribution-function lattice Boltzmann method is developed for the compressible Navier-Stokes equations. Different from existing thermal lattice Boltzmann methods, this method can recover the compressible Navier-Stokes equations with a flexible specific-heat ratio and Prandtl number. In the method, a density distribution function based on a multispeed lattice is used to recover the compressible continuity and momentum equations, while the compressible energy equation is recovered by an energy distribution function. The energy distribution function is then coupled to the density distribution function via the thermal equation of state. In order to obtain an adjustable specific-heat ratio, a constant related to the specific-heat ratio is introduced into the equilibrium energy distribution function. Two different coupled double-distribution-function lattice Boltzmann models are also proposed in the paper. Numerical simulations are performed for the Riemann problem, the double-Mach-reflection problem, and the Couette flow with a range of specific-heat ratios and Prandtl numbers. The numerical results are found to be in excellent agreement with analytical and/or other solutions.

  7. High attenuation areas on chest computed tomography in community-dwelling adults: the MESA study.

    PubMed

    Podolanczuk, Anna J; Oelsner, Elizabeth C; Barr, R Graham; Hoffman, Eric A; Armstrong, Hilary F; Austin, John H M; Basner, Robert C; Bartels, Matthew N; Christie, Jason D; Enright, Paul L; Gochuico, Bernadette R; Hinckley Stukovsky, Karen; Kaufman, Joel D; Hrudaya Nath, P; Newell, John D; Palmer, Scott M; Rabinowitz, Dan; Raghu, Ganesh; Sell, Jessica L; Sieren, Jered; Sonavane, Sushil K; Tracy, Russell P; Watts, Jubal R; Williams, Kayleen; Kawut, Steven M; Lederer, David J

    2016-11-01

    Evidence suggests that lung injury, inflammation and extracellular matrix remodelling precede lung fibrosis in interstitial lung disease (ILD). We examined whether a quantitative measure of increased lung attenuation on computed tomography (CT) detects lung injury, inflammation and extracellular matrix remodelling in community-dwelling adults sampled without regard to respiratory symptoms or smoking.We measured high attenuation areas (HAA; percentage of lung voxels between -600 and -250 Hounsfield Units) on cardiac CT scans of adults enrolled in the Multi-Ethnic Study of Atherosclerosis.HAA was associated with higher serum matrix metalloproteinase-7 (mean adjusted difference 6.3% per HAA doubling, 95% CI 1.3-11.5), higher interleukin-6 (mean adjusted difference 8.8%, 95% CI 4.8-13.0), lower forced vital capacity (FVC) (mean adjusted difference -82 mL, 95% CI -119--44), lower 6-min walk distance (mean adjusted difference -40 m, 95% CI -1--80), higher odds of interstitial lung abnormalities at 9.5 years (adjusted OR 1.95, 95% CI 1.43-2.65), and higher all cause-mortality rate over 12.2 years (HR 1.58, 95% CI 1.39-1.79).High attenuation areas are associated with biomarkers of inflammation and extracellular matrix remodelling, reduced lung function, interstitial lung abnormalities, and a higher risk of death among community-dwelling adults. Copyright ©ERS 2016.

  8. Clinical outcomes of arthroscopic single and double row repair in full thickness rotator cuff tears

    PubMed Central

    Ji, Jong-Hun; Shafi, Mohamed; Kim, Weon-Yoo; Kim, Young-Yul

    2010-01-01

    Background: There has been a recent interest in the double row repair method for arthroscopic rotator cuff repair following favourable biomechanical results reported by some studies. The purpose of this study was to compare the clinical results of arthroscopic single row and double row repair methods in the full-thickness rotator cuff tears. Materials and Methods: 22 patients of arthroscopic single row repair (group I) and 25 patients who underwent double row repair (group II) from March 2003 to March 2005 were retrospectively evaluated and compared for the clinical outcomes. The mean age was 58 years and 56 years respectively for group I and II. The average follow-up in the two groups was 24 months. The evaluation was done by using the University of California Los Angeles (UCLA) rating scale and the shoulder index of the American Shoulder and Elbow Surgeons (ASES). Results: In Group I, the mean ASES score increased from 30.48 to 87.40 and the mean ASES score increased from 32.00 to 91.45 in the Group II. The mean UCLA score increased from the preoperative 12.23 to 30.82 in Group I and from 12.20 to 32.40 in Group II. Each method has shown no statistical clinical differences between two methods, but based on the sub scores of UCLA score, the double row repair method yields better results for the strength, and it gives more satisfaction to the patients than the single row repair method. Conclusions: Comparing the two methods, double row repair group showed better clinical results in recovering strength and gave more satisfaction to the patients but no statistical clinical difference was found between 2 methods. PMID:20697485

  9. Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique.

    PubMed

    Robinson, Sean; Krigbaum, Henry; Kramer, Jon; Purviance, Connor; Parrish, Robin; Donahue, Joseph

    2018-06-01

    There are numerous configurations of double row fixation for rotator cuff tears however, there remains to be a consensus on the best method. In this study, we evaluated three different double-row configurations, including a new method. Our primary question is whether the new anchor and technique compares in biomechanical strength to standard double row techniques. Eighteen prepared fresh frozen bovine infraspinatus tendons were randomized to one of three groups including the New Double Row Equivalent, Arthrex Speedbridge and a transosseous equivalent using standard Stabilynx anchors. Biomechanical testing was performed on humeri sawbones and ultimate load, strain, yield strength, contact area, contact pressure, and a survival plots were evaluated. The new double row equivalent method demonstrated increased survival as well as ultimate strength at 415N compared to the remainder testing groups as well as equivalent contact area and pressure to standard double row techniques. This new anchor system and technique demonstrated higher survival rates and loads to failure than standard double row techniques. This data provides us with a new method of rotator cuff fixation which should be further evaluated in the clinical setting. Basic science biomechanical study.

  10. Linear Array Ambient Noise Adjoint Tomography Reveals Intense Crust-Mantle Interactions in North China Craton

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Yao, Huajian; Liu, Qinya; Zhang, Ping; Yuan, Yanhua O.; Feng, Jikun; Fang, Lihua

    2018-01-01

    We present a 2-D ambient noise adjoint tomography technique for a linear array with a significant reduction in computational cost and show its application to an array in North China. We first convert the observed data for 3-D media, i.e., surface-wave empirical Green's functions (EGFs) to the reconstructed EGFs (REGFs) for 2-D media using a 3-D/2-D transformation scheme. Different from the conventional steps of measuring phase dispersion, this technology refines 2-D shear wave speeds along the profile directly from REGFs. With an initial model based on traditional ambient noise tomography, adjoint tomography updates the model by minimizing the frequency-dependent Rayleigh wave traveltime delays between the REGFs and synthetic Green functions calculated by the spectral-element method. The multitaper traveltime difference measurement is applied in four-period bands: 20-35 s, 15-30 s, 10-20 s, and 6-15 s. The recovered model shows detailed crustal structures including pronounced low-velocity anomalies in the lower crust and a gradual crust-mantle transition zone beneath the northern Trans-North China Orogen, which suggest the possible intense thermo-chemical interactions between mantle-derived upwelling melts and the lower crust, probably associated with the magmatic underplating during the Mesozoic to Cenozoic evolution of this region. To our knowledge, it is the first time that ambient noise adjoint tomography is implemented for a 2-D medium. Compared with the intensive computational cost and storage requirement of 3-D adjoint tomography, this method offers a computationally efficient and inexpensive alternative to imaging fine-scale crustal structures beneath linear arrays.

  11. LASER BIOLOGY AND MEDICINE: Combined application of optical methods to increase the information content of optical coherent tomography in diagnostics of neoplastic processes

    NASA Astrophysics Data System (ADS)

    Kuranov, R. V.; Sapozhnikova, V. V.; Shakhova, N. M.; Gelikonov, V. M.; Zagainova, E. V.; Petrova, S. A.

    2002-11-01

    A combined application of optical methods [optical coherent tomography (OCT), cross-polarisation optical coherent tomography, and fluorescence spectroscopy] is proposed for obtaining information on morphological and biochemical changes occurring in tissues in norm and pathology. It is shown that neoplastic and scar changes in esophagus can be distinguished using a combination of polarisation and standard OCT due to the difference between the depolarising properties of the tissues caused by the structural properties of collagenic fibres in stroma. It is shown that OCT combined with fluorescence spectroscopy with the use of 5-aminolevulinic acid is promising for determining the boundaries of carcinoma of the uterine cervix and vulva. It is found that the tumour boundary detected by optical methods coincides with the morphological boundary and extends beyond colposcopically determined boundary by about 2 mm.

  12. Medium-scale traveling ionospheric disturbances by three-dimensional ionospheric GPS tomography

    NASA Astrophysics Data System (ADS)

    Chen, C. H.; Saito, A.; Lin, C. H.; Yamamoto, M.; Suzuki, S.; Seemala, G. K.

    2016-02-01

    In this study, we develop a three-dimensional ionospheric tomography with the ground-based global position system (GPS) total electron content observations. Because of the geometric limitation of GPS observation path, it is difficult to solve the ill-posed inverse problem for the ionospheric electron density. Different from methods given by pervious studies, we consider an algorithm combining the least-square method with a constraint condition, in which the gradient of electron density tends to be smooth in the horizontal direction and steep in the vicinity of the ionospheric F2 peak. This algorithm is designed to be independent of any ionospheric or plasmaspheric electron density models as the initial condition. An observation system simulation experiment method is applied to evaluate the performance of the GPS ionospheric tomography in detecting ionospheric electron density perturbation at the scale size of around 200 km in wavelength, such as the medium-scale traveling ionospheric disturbances.

  13. Combined application of optical methods to increase the information content of optical coherent tomography in diagnostics of neoplastic processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuranov, R V; Sapozhnikova, V V; Shakhova, N M

    2002-11-30

    A combined application of optical methods [optical coherent tomography (OCT), cross-polarisation optical coherent tomography, and fluorescence spectroscopy] is proposed for obtaining information on morphological and biochemical changes occurring in tissues in norm and pathology. It is shown that neoplastic and scar changes in esophagus can be distinguished using a combination of polarisation and standard OCT due to the difference between the depolarising properties of the tissues caused by the structural properties of collagenic fibres in stroma. It is shown that OCT combined with fluorescence spectroscopy with the use of 5-aminolevulinic acid is promising for determining the boundaries of carcinoma ofmore » the uterine cervix and vulva. It is found that the tumour boundary detected by optical methods coincides with the morphological boundary and extends beyond colposcopically determined boundary by about 2 mm. (laser biology and medicine)« less

  14. Three-dimensional structural dynamics and fluctuations of DNA-nanogold conjugates by individual-particle electron tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Lei, Dongsheng; Smith, Jessica M.; Zhang, Meng; Tong, Huimin; Zhang, Xing; Lu, Zhuoyang; Liu, Jiankang; Alivisatos, A. Paul; Ren, Gang

    2016-03-01

    DNA base pairing has been used for many years to direct the arrangement of inorganic nanocrystals into small groupings and arrays with tailored optical and electrical properties. The control of DNA-mediated assembly depends crucially on a better understanding of three-dimensional structure of DNA-nanocrystal-hybridized building blocks. Existing techniques do not allow for structural determination of these flexible and heterogeneous samples. Here we report cryo-electron microscopy and negative-staining electron tomography approaches to image, and three-dimensionally reconstruct a single DNA-nanogold conjugate, an 84-bp double-stranded DNA with two 5-nm nanogold particles for potential substrates in plasmon-coupling experiments. By individual-particle electron tomography reconstruction, we obtain 14 density maps at ~2-nm resolution. Using these maps as constraints, we derive 14 conformations of dsDNA by molecular dynamics simulations. The conformational variation is consistent with that from liquid solution, suggesting that individual-particle electron tomography could be an expected approach to study DNA-assembling and flexible protein structure and dynamics.

  15. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    PubMed

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. 3D imaging of nanomaterials by discrete tomography.

    PubMed

    Batenburg, K J; Bals, S; Sijbers, J; Kübel, C; Midgley, P A; Hernandez, J C; Kaiser, U; Encina, E R; Coronado, E A; Van Tendeloo, G

    2009-05-01

    The field of discrete tomography focuses on the reconstruction of samples that consist of only a few different materials. Ideally, a three-dimensional (3D) reconstruction of such a sample should contain only one grey level for each of the compositions in the sample. By exploiting this property in the reconstruction algorithm, either the quality of the reconstruction can be improved significantly, or the number of required projection images can be reduced. The discrete reconstruction typically contains fewer artifacts and does not have to be segmented, as it already contains one grey level for each composition. Recently, a new algorithm, called discrete algebraic reconstruction technique (DART), has been proposed that can be used effectively on experimental electron tomography datasets. In this paper, we propose discrete tomography as a general reconstruction method for electron tomography in materials science. We describe the basic principles of DART and show that it can be applied successfully to three different types of samples, consisting of embedded ErSi(2) nanocrystals, a carbon nanotube grown from a catalyst particle and a single gold nanoparticle, respectively.

  17. DOUBLE ENDOR with a linearly and a circularly polarized radiofrequency field

    NASA Astrophysics Data System (ADS)

    Schweiger, A.; Rudin, M.; Forrer, J.; Günthard, Hs. H.

    The combination of the two spectroscopical techniques, DOUBLE ENDOR and ENDOR with a circularly polarized radiofrequency field (CP-ENDOR), is described. with this new method, termed by the acronym CP-DOUBLE ENDOR, the selective induction of transitions of different types of nuclei and of different paramagnetic species allows a drastic reduction of the number of observed ENDOR lines. With this technique, analysis of hitherto not interpretable ENDOR spectra is often made possible. The experimental setup of the CP-DOUBLE ENDOR spectrometer is described. The advantage of using circularly polarized rf fields in DOUBLE ENDOR spectroscopy is illustrated by two applications on transition metal complexes in single crystals.

  18. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitsuyoshi, Takamasa; Nakamura, Mitsuhiro, E-mail: m_nkmr@kuhp.kyoto-u.ac.jp; Matsuo, Yukinori

    The purpose of this article is to quantitatively evaluate differences in dose distributions calculated using various computed tomography (CT) datasets, dose-calculation algorithms, and prescription methods in stereotactic body radiotherapy (SBRT) for patients with early-stage lung cancer. Data on 29 patients with early-stage lung cancer treated with SBRT were retrospectively analyzed. Averaged CT (Ave-CT) and expiratory CT (Ex-CT) images were reconstructed for each patient using 4-dimensional CT data. Dose distributions were initially calculated using the Ave-CT images and recalculated (in the same monitor units [MUs]) by employing Ex-CT images with the same beam arrangements. The dose-volume parameters, including D{sub 95}, D{submore » 90}, D{sub 50}, and D{sub 2} of the planning target volume (PTV), were compared between the 2 image sets. To explore the influence of dose-calculation algorithms and prescription methods on the differences in dose distributions evident between Ave-CT and Ex-CT images, we calculated dose distributions using the following 3 different algorithms: x-ray Voxel Monte Carlo (XVMC), Acuros XB (AXB), and the anisotropic analytical algorithm (AAA). We also used 2 different dose-prescription methods; the isocenter prescription and the PTV periphery prescription methods. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data were within 3 percentage points (%pts) employing the isocenter prescription method, and within 1.5%pts using the PTV periphery prescription method, irrespective of which of the 3 algorithms (XVMC, AXB, and AAA) was employed. The frequencies of dose-volume parameters differing by >1%pt when the XVMC and AXB were used were greater than those associated with the use of the AAA, regardless of the dose-prescription method employed. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data on patients who underwent lung SBRT were within 3%pts, regardless of the dose-calculation algorithm or the dose-prescription method employed.« less

  19. Non-double-couple microearthquakes at Long Valley caldera, California, provide evidence for hydraulic fracturing

    USGS Publications Warehouse

    Foulger, G.R.; Julian, B.R.; Hill, D.P.; Pitt, A.M.; Malin, P.E.; Shalev, E.

    2004-01-01

    Most of 26 small (0.4??? M ???3.1) microearthquakes at Long Valley caldera in mid-1997, analyzed using data from a dense temporary network of 69 digital three-component seismometers, have significantly non-double-couple focal mechanisms, inconsistent with simple shear faulting. We determined their mechanisms by inverting P - and S -wave polarities and amplitude ratios using linear-programming methods, and tracing rays through a three-dimensional Earth model derived using tomography. More than 80% of the mechanisms have positive (volume increase) isotropic components and most have compensated linear-vector dipole components with outward-directed major dipoles. The simplest interpretation of these mechanisms is combined shear and extensional faulting with a volume-compensating process, such as rapid flow of water, steam, or CO2 into opening tensile cracks. Source orientations of earthquakes in the south moat suggest extensional faulting on ESE-striking subvertical planes, an orientation consistent with planes defined by earthquake hypocenters. The focal mechanisms show that clearly defined hypocentral planes in different locations result from different source processes. One such plane in the eastern south moat is consistent with extensional faulting, while one near Casa Diablo Hot Springs reflects en echelon right-lateral shear faulting. Source orientations at Mammoth Mountain vary systematically with location, indicating that the volcano influences the local stress field. Events in a 'spasmodic burst' at Mammoth Mountain have practically identical mechanisms that indicate nearly pure compensated tensile failure and high fluid mobility. Five earthquakes had mechanisms involving small volume decreases, but these may not be significant. No mechanisms have volumetric moment fractions larger than that of a force dipole, but the reason for this fact is unknown. Published by Elsevier B.V.

  20. [Measurement of intracranial hematoma volume by personal computer].

    PubMed

    DU, Wanping; Tan, Lihua; Zhai, Ning; Zhou, Shunke; Wang, Rui; Xue, Gongshi; Xiao, An

    2011-01-01

    To explore the method for intracranial hematoma volume measurement by the personal computer. Forty cases of various intracranial hematomas were measured by the computer tomography with quantitative software and personal computer with Photoshop CS3 software, respectively. the data from the 2 methods were analyzed and compared. There was no difference between the data from the computer tomography and the personal computer (P>0.05). The personal computer with Photoshop CS3 software can measure the volume of various intracranial hematomas precisely, rapidly and simply. It should be recommended in the clinical medicolegal identification.

  1. Quantitative measurements of regional glucose utilization and rate of valine incorporation into proteins by double-tracer autoradiography in the rat brain tumor model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirikae, M.; Diksic, M.; Yamamoto, Y.L.

    1989-02-01

    We examined the rate of glucose utilization and the rate of valine incorporation into proteins using 2-(/sup 18/F)fluoro-2-deoxyglucose and L-(1-14C)-valine in a rat brain tumor model by quantitative double-tracer autoradiography. We found that in the implanted tumor the rate of valine incorporation into proteins was about 22 times and the rate of glucose utilization was about 1.5 times that in the contralateral cortex. (In the ipsilateral cortex, the tumor had a profound effect on glucose utilization but no effect on the rate of valine incorporation into proteins.) Our findings suggest that it is more useful to measure protein synthesis thanmore » glucose utilization to assess the effectiveness of antitumor agents and their toxicity to normal brain tissue. We compared two methods to estimate the rate of valine incorporation: kinetic (quantitation done using an operational equation and the average brain rate coefficients) and washed slices (unbound labeled valine removed by washing brain slices in 10% trichloroacetic acid). The results were the same using either method. It would seem that the kinetic method can thus be used for quantitative measurement of protein synthesis in brain tumors and normal brain tissue using (/sup 11/C)-valine with positron emission tomography.« less

  2. Comparison of Tissue Density in Hounsfield Units in Computed Tomography and Cone Beam Computed Tomography.

    PubMed

    Varshowsaz, Masoud; Goorang, Sepideh; Ehsani, Sara; Azizi, Zeynab; Rahimian, Sepideh

    2016-03-01

    Bone quality and quantity assessment is one of the most important steps in implant treatment planning. Different methods such as computed tomography (CT) and recently suggested cone beam computed tomography (CBCT) with lower radiation dose and less time and cost are used for bone density assessment. This in vitro study aimed to compare the tissue density values in Hounsfield units (HUs) in CBCT and CT scans of different tissue phantoms with two different thicknesses, two different image acquisition settings and in three locations in the phantoms. Four different tissue phantoms namely hard tissue, soft tissue, air and water were scanned by three different CBCT and a CT system in two thicknesses (full and half) and two image acquisition settings (high and low kVp and mA). The images were analyzed at three sites (middle, periphery and intermediate) using eFilm software. The difference in density values was analyzed by ANOVA and correction coefficient test (P<0.05). There was a significant difference between density values in CBCT and CT scans in most situations, and CBCT values were not similar to CT values in any of the phantoms in different thicknesses and acquisition parameters or the three different sites. The correction coefficients confirmed the results. CBCT is not reliable for tissue density assessment. The results were not affected by changes in thickness, acquisition parameters or locations.

  3. A single-image method for x-ray refractive index CT.

    PubMed

    Mittone, A; Gasilov, S; Brun, E; Bravin, A; Coan, P

    2015-05-07

    X-ray refraction-based computer tomography imaging is a well-established method for nondestructive investigations of various objects. In order to perform the 3D reconstruction of the index of refraction, two or more raw computed tomography phase-contrast images are usually acquired and combined to retrieve the refraction map (i.e. differential phase) signal within the sample. We suggest an approximate method to extract the refraction signal, which uses a single raw phase-contrast image. This method, here applied to analyzer-based phase-contrast imaging, is employed to retrieve the index of refraction map of a biological sample. The achieved accuracy in distinguishing the different tissues is comparable with the non-approximated approach. The suggested procedure can be used for precise refraction computer tomography with the advantage of a reduction of at least a factor of two of both the acquisition time and the dose delivered to the sample with respect to any of the other algorithms in the literature.

  4. Clinical outcomes of arthroscopic single and double row repair in full thickness rotator cuff tears.

    PubMed

    Ji, Jong-Hun; Shafi, Mohamed; Kim, Weon-Yoo; Kim, Young-Yul

    2010-07-01

    There has been a recent interest in the double row repair method for arthroscopic rotator cuff repair following favourable biomechanical results reported by some studies. The purpose of this study was to compare the clinical results of arthroscopic single row and double row repair methods in the full-thickness rotator cuff tears. 22 patients of arthroscopic single row repair (group I) and 25 patients who underwent double row repair (group II) from March 2003 to March 2005 were retrospectively evaluated and compared for the clinical outcomes. The mean age was 58 years and 56 years respectively for group I and II. The average follow-up in the two groups was 24 months. The evaluation was done by using the University of California Los Angeles (UCLA) rating scale and the shoulder index of the American Shoulder and Elbow Surgeons (ASES). In Group I, the mean ASES score increased from 30.48 to 87.40 and the mean ASES score increased from 32.00 to 91.45 in the Group II. The mean UCLA score increased from the preoperative 12.23 to 30.82 in Group I and from 12.20 to 32.40 in Group II. Each method has shown no statistical clinical differences between two methods, but based on the sub scores of UCLA score, the double row repair method yields better results for the strength, and it gives more satisfaction to the patients than the single row repair method. Comparing the two methods, double row repair group showed better clinical results in recovering strength and gave more satisfaction to the patients but no statistical clinical difference was found between 2 methods.

  5. Evaluation of the validity of the Bolton Index using cone-beam computed tomography (CBCT)

    PubMed Central

    Llamas, José M.; Cibrián, Rosa; Gandía, José L.; Paredes, Vanessa

    2012-01-01

    Aims: To evaluate the reliability and reproducibility of calculating the Bolton Index using cone-beam computed tomography (CBCT), and to compare this with measurements obtained using the 2D Digital Method. Material and Methods: Traditional study models were obtained from 50 patients, which were then digitized in order to be able to measure them using the Digital Method. Likewise, CBCTs of those same patients were undertaken using the Dental Picasso Master 3D® and the images obtained were then analysed using the InVivoDental programme. Results: By determining the regression lines for both measurement methods, as well as the difference between both of their values, the two methods are shown to be comparable, despite the fact that the measurements analysed presented statistically significant differences. Conclusions: The three-dimensional models obtained from the CBCT are as accurate and reproducible as the digital models obtained from the plaster study casts for calculating the Bolton Index. The differences existing between both methods were clinically acceptable. Key words:Tooth-size, digital models, bolton index, CBCT. PMID:22549690

  6. Applications for Electrical Impedance Tomography (EIT) and Electrical Properties of the Human Body.

    PubMed

    Lymperopoulos, Georgios; Lymperopoulos, Panagiotis; Alikari, Victoria; Dafogianni, Chrisoula; Zyga, Sofia; Margari, Nikoletta

    2017-01-01

    Electrical Impedance Tomography (EIT) is a promising application that displays changes in conductivity within a body. The basic principle of the method is the repeated measurement of surface voltages of a body, which are a result of rolling injection of known and small-volume sinusoidal AC current to the body through the electrodes attached to its surface. This method finds application in biomedicine, biology and geology. The objective of this paper is to present the applications of Electrical Impedance Tomography, along with the method's capabilities and limitations due to the electrical properties of the human body. For this purpose, investigation of existing literature has been conducted, using electronic databases, PubMed, Google Scholar and IEEE Xplore. In addition, there was a secondary research phase, using paper citations found during the first research phase. It should be noted that Electrical Impedance Tomography finds use in a plethora of medical applications, as the different tissues of the body have different conductivities and dielectric constants. Main applications of EIT include imaging of lung function, diagnosis of pulmonary embolism, detection of tumors in the chest area and diagnosis and distinction of ischemic and hemorrhagic stroke. EIT advantages include portability, low cost and safety, which the method provide, since it is a noninvasive imaging method that does not cause damage to the body. The main disadvantage of the method, which blocks its wider spread, appears in the image composition from the voltage measurements, which are conducted by electrodes placed on the periphery of the body, because the injected currents are affected nonlinearly by the general distribution of the electrical properties of the body. Furthermore, the complex impedance of the skin-electrode interface can be modelled by using a capacitor and two resistor, as a result of skin properties. In conclusion, Electrical Impedance Tomography is a promising method for the development of noninvasive diagnostic medicine, since it is able to provide imaging of the interior of the human body in real time without causing harm or putting the human body in risk.

  7. Imaging in anatomy: a comparison of imaging techniques in embalmed human cadavers

    PubMed Central

    2013-01-01

    Background A large variety of imaging techniques is an integral part of modern medicine. Introducing radiological imaging techniques into the dissection course serves as a basis for improved learning of anatomy and multidisciplinary learning in pre-clinical medical education. Methods Four different imaging techniques (ultrasound, radiography, computed tomography, and magnetic resonance imaging) were performed in embalmed human body donors to analyse possibilities and limitations of the respective techniques in this peculiar setting. Results The quality of ultrasound and radiography images was poor, images of computed tomography and magnetic resonance imaging were of good quality. Conclusion Computed tomography and magnetic resonance imaging have a superior image quality in comparison to ultrasound and radiography and offer suitable methods for imaging embalmed human cadavers as a valuable addition to the dissection course. PMID:24156510

  8. Comparison of different numerical treatments for x-ray phase tomography of soft tissue from differential phase projections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelliccia, Daniele; Vaz, Raquel; Svalbe, Imants

    X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve themore » same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.« less

  9. Pseudoaneurysm of the articular branch of the descending genicular artery following double-bundle anterior cruciate ligament reconstruction.

    PubMed

    Tsubosaka, Masanori; Matsushita, Takehiko; Kuroda, Ryosuke; Matsumoto, Tomoyuki; Kurosaka, Masahiro

    2017-09-01

    This report describes a case of a pseudoaneurysm of the articular branch of the descending genicular artery following double-bundle anterior cruciate ligament (ACL) reconstruction. An 18-year-old male received double-bundle ACL reconstruction. During ACL reconstruction, a far anteromedial portal was created for femoral tunnel drilling. The patient presented with pulsatile swelling on the medial side of the knee on the second post-operative day. The pseudoaneurysm was diagnosed using contrast computed tomography and Doppler ultrasonography and was subsequently treated by embolization with a microcatheter. Although a vascular injury is a very rare complication of knee arthroscopy, it should be considered a possibility in patients who undergo such procedures. V.

  10. Biomechanical analysis of titanium fixation plates and screws in sagittal split ramus osteotomies.

    PubMed

    Atik, F; Atac, M S; Özkan, A; Kılınc, Y; Arslan, M

    2016-01-01

    The aim of the study was to evaluate the mechanical behavior of three different fixation methods used in the bilateral sagittal split ramus osteotomy. Three different three-dimensional finite element models were created, each corresponding to three different fixation methods. The mandibles were fixed with double straight 4-hole, square 4-hole, and 5-hole Y plates. 150 N incisal occlusal loads were simulated on the distal segments. ANSYS software ((v 10; ANSYS Inc., Canonsburg, PA) was used to calculate the Von Mises stresses on fixative appliances. The highest Von Mises stress values were found in Y plate. The lowest values were isolated in double straight plate group. It was concluded that the use of double 4-hole straight plates provided the sufficient stability on the osteotomy site when compared with the other rigid fixation methods used in this study.

  11. A geometricla error in some Computer Programs based on the Aki-Christofferson-Husebye (ACH) Method of Teleseismic Tomography

    USGS Publications Warehouse

    Julian, B.R.; Evans, J.R.; Pritchard, M.J.; Foulger, G.R.

    2000-01-01

    Some computer programs based on the Aki-Christofferson-Husebye (ACH) method of teleseismic tomography contain an error caused by identifying local grid directions with azimuths on the spherical Earth. This error, which is most severe in high latitudes, introduces systematic errors into computed ray paths and distorts inferred Earth models. It is best dealt with by explicity correcting for the difference between true and grid directions. Methods for computing these directions are presented in this article and are likely to be useful in many other kinds of regional geophysical studies that use Cartesian coordinates and flat-earth approximations.

  12. An augmented Lagrangian trust region method for inclusion boundary reconstruction using ultrasound/electrical dual-modality tomography

    NASA Astrophysics Data System (ADS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2018-07-01

    The ultrasound/electrical dual-modality tomography utilizes the complementarity of ultrasound reflection tomography (URT) and electrical impedance tomography (EIT) to improve the speed and accuracy of image reconstruction. Due to its advantages of no-invasive, no-radiation and low-cost, ultrasound/electrical dual-modality tomography has attracted much attention in the field of dual-modality imaging and has many potential applications in industrial and biomedical imaging. However, the data fusion of URT and EIT is difficult due to their different theoretical foundations and measurement principles. The most commonly used data fusion strategy in ultrasound/electrical dual-modality tomography is incorporating the structured information extracted from the URT into the EIT image reconstruction process through a pixel-based constraint. Due to the inherent non-linearity and ill-posedness of EIT, the reconstructed images from the strategy suffer from the low resolution, especially at the boundary of the observed inclusions. To improve this condition, an augmented Lagrangian trust region method is proposed to directly reconstruct the shapes of the inclusions from the ultrasound/electrical dual-modality measurements. In the proposed method, the shape of the target inclusion is parameterized by a radial shape model whose coefficients are used as the shape parameters. Then, the dual-modality shape inversion problem is formulated by an energy minimization problem in which the energy function derived from EIT is constrained by an ultrasound measurements model through an equality constraint equation. Finally, the optimal shape parameters associated with the optimal inclusion shape guesses are determined by minimizing the constrained cost function using the augmented Lagrangian trust region method. To evaluate the proposed method, numerical tests are carried out. Compared with single modality EIT, the proposed dual-modality inclusion boundary reconstruction method has a higher accuracy and is more robust to the measurement noise.

  13. Physically corrected forward operators for induced emission tomography: a simulation study

    NASA Astrophysics Data System (ADS)

    Viganò, Nicola Roberto; Solé, Vicente Armando

    2018-03-01

    X-ray emission tomography techniques over non-radioactive materials allow one to investigate different and important aspects of the matter that are usually not addressable with the standard x-ray transmission tomography, such as density, chemical composition and crystallographic information. However, the quantitative reconstruction of these investigated properties is hindered by additional problems, including the self-attenuation of the emitted radiation. Work has been done in the past, especially concerning x-ray fluorescence tomography, but this has always focused on solving very specific problems. The novelty of this work resides in addressing the problem of induced emission tomography from a much wider perspective, introducing a unified discrete representation that can be used to modify existing algorithms to reconstruct the data of the different types of experiments. The direct outcome is a clear and easy mathematical description of the implementation details of such algorithms, despite small differences in geometry and other practical aspects, but also the possibility to express the reconstruction as a minimization problem, allowing the use of variational methods, and a more flexible modeling of the noise involved in the detection process. In addition, we look at the results of a few selected simulated data reconstructions that describe the effect of physical corrections like the self-attenuation, and the response to noise of the adapted reconstruction algorithms.

  14. A Dictionary Learning Approach with Overlap for the Low Dose Computed Tomography Reconstruction and Its Vectorial Application to Differential Phase Tomography

    PubMed Central

    Mirone, Alessandro; Brun, Emmanuel; Coan, Paola

    2014-01-01

    X-ray based Phase-Contrast Imaging (PCI) techniques have been demonstrated to enhance the visualization of soft tissues in comparison to conventional imaging methods. Nevertheless the delivered dose as reported in the literature of biomedical PCI applications often equals or exceeds the limits prescribed in clinical diagnostics. The optimization of new computed tomography strategies which include the development and implementation of advanced image reconstruction procedures is thus a key aspect. In this scenario, we implemented a dictionary learning method with a new form of convex functional. This functional contains in addition to the usual sparsity inducing and fidelity terms, a new term which forces similarity between overlapping patches in the superimposed regions. The functional depends on two free regularization parameters: a coefficient multiplying the sparsity-inducing norm of the patch basis functions coefficients, and a coefficient multiplying the norm of the differences between patches in the overlapping regions. The solution is found by applying the iterative proximal gradient descent method with FISTA acceleration. The gradient is computed by calculating projection of the solution and its error backprojection at each iterative step. We study the quality of the solution, as a function of the regularization parameters and noise, on synthetic data for which the solution is a-priori known. We apply the method on experimental data in the case of Differential Phase Tomography. For this case we use an original approach which consists in using vectorial patches, each patch having two components: one per each gradient component. The resulting algorithm, implemented in the European Synchrotron Radiation Facility tomography reconstruction code PyHST, has proven to be efficient and well-adapted to strongly reduce the required dose and the number of projections in medical tomography. PMID:25531987

  15. A dictionary learning approach with overlap for the low dose computed tomography reconstruction and its vectorial application to differential phase tomography.

    PubMed

    Mirone, Alessandro; Brun, Emmanuel; Coan, Paola

    2014-01-01

    X-ray based Phase-Contrast Imaging (PCI) techniques have been demonstrated to enhance the visualization of soft tissues in comparison to conventional imaging methods. Nevertheless the delivered dose as reported in the literature of biomedical PCI applications often equals or exceeds the limits prescribed in clinical diagnostics. The optimization of new computed tomography strategies which include the development and implementation of advanced image reconstruction procedures is thus a key aspect. In this scenario, we implemented a dictionary learning method with a new form of convex functional. This functional contains in addition to the usual sparsity inducing and fidelity terms, a new term which forces similarity between overlapping patches in the superimposed regions. The functional depends on two free regularization parameters: a coefficient multiplying the sparsity-inducing L1 norm of the patch basis functions coefficients, and a coefficient multiplying the L2 norm of the differences between patches in the overlapping regions. The solution is found by applying the iterative proximal gradient descent method with FISTA acceleration. The gradient is computed by calculating projection of the solution and its error backprojection at each iterative step. We study the quality of the solution, as a function of the regularization parameters and noise, on synthetic data for which the solution is a-priori known. We apply the method on experimental data in the case of Differential Phase Tomography. For this case we use an original approach which consists in using vectorial patches, each patch having two components: one per each gradient component. The resulting algorithm, implemented in the European Synchrotron Radiation Facility tomography reconstruction code PyHST, has proven to be efficient and well-adapted to strongly reduce the required dose and the number of projections in medical tomography.

  16. Double-dictionary matching pursuit for fault extent evaluation of rolling bearing based on the Lempel-Ziv complexity

    NASA Astrophysics Data System (ADS)

    Cui, Lingli; Gong, Xiangyang; Zhang, Jianyu; Wang, Huaqing

    2016-12-01

    The quantitative diagnosis of rolling bearing fault severity is particularly crucial to realize a proper maintenance decision. Aiming at the fault feature of rolling bearing, a novel double-dictionary matching pursuit (DDMP) for fault extent evaluation of rolling bearing based on the Lempel-Ziv complexity (LZC) index is proposed in this paper. In order to match the features of rolling bearing fault, the impulse time-frequency dictionary and modulation dictionary are constructed to form the double-dictionary by using the method of parameterized function model. Then a novel matching pursuit method is proposed based on the new double-dictionary. For rolling bearing vibration signals with different fault sizes, the signals are decomposed and reconstructed by the DDMP. After the noise reduced and signals reconstructed, the LZC index is introduced to realize the fault extent evaluation. The applications of this method to the fault experimental signals of bearing outer race and inner race with different degree of injury have shown that the proposed method can effectively realize the fault extent evaluation.

  17. Tomographic reconstruction of melanin structures of optical coherence tomography via the finite-difference time-domain simulation

    NASA Astrophysics Data System (ADS)

    Huang, Shi-Hao; Wang, Shiang-Jiu; Tseng, Snow H.

    2015-03-01

    Optical coherence tomography (OCT) provides high resolution, cross-sectional image of internal microstructure of biological tissue. We use the Finite-Difference Time-Domain method (FDTD) to analyze the data acquired by OCT, which can help us reconstruct the refractive index of the biological tissue. We calculate the refractive index tomography and try to match the simulation with the data acquired by OCT. Specifically, we try to reconstruct the structure of melanin, which has complex refractive indices and is the key component of human pigment system. The results indicate that better reconstruction can be achieved for homogenous sample, whereas the reconstruction is degraded for samples with fine structure or with complex interface. Simulation reconstruction shows structures of the Melanin that may be useful for biomedical optics applications.

  18. Novel fusion for hybrid optical/microcomputed tomography imaging based on natural light surface reconstruction and iterated closest point

    NASA Astrophysics Data System (ADS)

    Ning, Nannan; Tian, Jie; Liu, Xia; Deng, Kexin; Wu, Ping; Wang, Bo; Wang, Kun; Ma, Xibo

    2014-02-01

    In mathematics, optical molecular imaging including bioluminescence tomography (BLT), fluorescence tomography (FMT) and Cerenkov luminescence tomography (CLT) are concerned with a similar inverse source problem. They all involve the reconstruction of the 3D location of a single/multiple internal luminescent/fluorescent sources based on 3D surface flux distribution. To achieve that, an accurate fusion between 2D luminescent/fluorescent images and 3D structural images that may be acquired form micro-CT, MRI or beam scanning is extremely critical. However, the absence of a universal method that can effectively convert 2D optical information into 3D makes the accurate fusion challengeable. In this study, to improve the fusion accuracy, a new fusion method for dual-modality tomography (luminescence/fluorescence and micro-CT) based on natural light surface reconstruction (NLSR) and iterated closest point (ICP) was presented. It consisted of Octree structure, exact visual hull from marching cubes and ICP. Different from conventional limited projection methods, it is 360° free-space registration, and utilizes more luminescence/fluorescence distribution information from unlimited multi-orientation 2D optical images. A mouse mimicking phantom (one XPM-2 Phantom Light Source, XENOGEN Corporation) and an in-vivo BALB/C mouse with implanted one luminescent light source were used to evaluate the performance of the new fusion method. Compared with conventional fusion methods, the average error of preset markers was improved by 0.3 and 0.2 pixels from the new method, respectively. After running the same 3D internal light source reconstruction algorithm of the BALB/C mouse, the distance error between the actual and reconstructed internal source was decreased by 0.19 mm.

  19. Robust membrane detection based on tensor voting for electron tomography.

    PubMed

    Martinez-Sanchez, Antonio; Garcia, Inmaculada; Asano, Shoh; Lucic, Vladan; Fernandez, Jose-Jesus

    2014-04-01

    Electron tomography enables three-dimensional (3D) visualization and analysis of the subcellular architecture at a resolution of a few nanometers. Segmentation of structural components present in 3D images (tomograms) is often necessary for their interpretation. However, it is severely hampered by a number of factors that are inherent to electron tomography (e.g. noise, low contrast, distortion). Thus, there is a need for new and improved computational methods to facilitate this challenging task. In this work, we present a new method for membrane segmentation that is based on anisotropic propagation of the local structural information using the tensor voting algorithm. The local structure at each voxel is then refined according to the information received from other voxels. Because voxels belonging to the same membrane have coherent structural information, the underlying global structure is strengthened. In this way, local information is easily integrated at a global scale to yield segmented structures. This method performs well under low signal-to-noise ratio typically found in tomograms of vitrified samples under cryo-tomography conditions and can bridge gaps present on membranes. The performance of the method is demonstrated by applications to tomograms of different biological samples and by quantitative comparison with standard template matching procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Distributed RF Tomography for Tunnel Detection: Suitable Inversion Schemes

    DTIC Science & Technology

    2009-01-01

    methods, ranging from seismic to electromagnetic waves, or from gravity to optics, from impedance tomography to magnetotellurics, no technique...unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Borehole GPR, which may...one manner to different targets (when targets are well-resolved). In particular, the wavefront generated by the array , when excited by one of these

  1. [The clinical economic analysis of the methods of ischemic heart disease diagnostics].

    PubMed

    Kalashnikov, V Iu; Mitriagina, S N; Syrkin, A L; Poltavskaia, M G; Sorokina, E G

    2007-01-01

    The clinical economical analysis was applied to assess the application of different techniques of ischemic heart disease diagnostics - the electro-cardiographic monitoring, the treadmill-testing, the stress-echo cardiographic with dobutamine, the single-photon computerized axial tomography with load, the multi-spiral computerized axial tomography with coronary arteries staining in patients with different initial probability of disease occurrence. In all groups, the best value of "cost-effectiveness" had the treadmill-test. The patients with low risk needed 17.4 rubles to precise the probability of ischemic heart disease occurrence at 1%. In the group with medium and high risk this indicator was 9.4 and 24.7 rubles correspondingly. It is concluded that to precise the probability of ischemic heart disease occurrence after tredmil-test in the patients with high probability it is appropriate to use the single-photon computerized axial tomography with load and in the case of patients with low probability the multi-spiral computerized axial tomography with coronary arteries staining.

  2. Direct estimation of human trabecular bone stiffness using cone beam computed tomography.

    PubMed

    Klintström, Eva; Klintström, Benjamin; Pahr, Dieter; Brismar, Torkel B; Smedby, Örjan; Moreno, Rodrigo

    2018-04-10

    The aim of this study was to evaluate the possibility of estimating the biomechanical properties of trabecular bone through finite element simulations by using dental cone beam computed tomography data. Fourteen human radius specimens were scanned in 3 cone beam computed tomography devices: 3-D Accuitomo 80 (J. Morita MFG., Kyoto, Japan), NewTom 5 G (QR Verona, Verona, Italy), and Verity (Planmed, Helsinki, Finland). The imaging data were segmented by using 2 different methods. Stiffness (Young modulus), shear moduli, and the size and shape of the stiffness tensor were studied. Corresponding evaluations by using micro-CT were regarded as the reference standard. The 3-D Accuitomo 80 (J. Morita MFG., Kyoto, Japan) showed good performance in estimating stiffness and shear moduli but was sensitive to the choice of segmentation method. NewTom 5 G (QR Verona, Verona, Italy) and Verity (Planmed, Helsinki, Finland) yielded good correlations, but they were not as strong as Accuitomo 80 (J. Morita MFG., Kyoto, Japan). The cone beam computed tomography devices overestimated both stiffness and shear compared with the micro-CT estimations. Finite element-based calculations of biomechanics from cone beam computed tomography data are feasible, with strong correlations for the Accuitomo 80 scanner (J. Morita MFG., Kyoto, Japan) combined with an appropriate segmentation method. Such measurements might be useful for predicting implant survival by in vivo estimations of bone properties. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Use of borehole radar tomography to monitor steam injection in fractured limestone

    USGS Publications Warehouse

    Gregoire, C.; Joesten, P.K.

    2006-01-01

    Borehole radar tomography was used as part of a pilot study to monitor steam-enhanced remediation of a fractured limestone contaminated with volatile organic compounds at the former Loring Air Force Base, Maine, USA. Radar tomography data were collected using 100-MHz electric-dipole antennae before and during steam injection to evaluate whether cross-hole radar methods could detect changes in medium properties resulting from the steam injection. Cross-hole levelrun profiles, in which transmitting and receiving antennae are positioned at a common depth, were made before and after the collection of each full tomography data set to check the stability of the radar instruments. Before tomographic inversion, the levelrun profiles were used to calibrate the radar tomography data to compensate for changes in traveltime and antenna power caused by instrument drift. Observed changes in cross-hole radar traveltime and attenuation before and during steam injection were small. Slowness- and attenuation-difference tomograms indicate small increases in radar slowness and attenuation at depths greater than about 22 m below the surface, consistent with increases in water temperature observed in the boreholes used for the tomography. Based on theoretical modelling results, increases in slowness and attenuation are interpreted as delineating zones where steam injection heating increased the electrical conductivity of the limestone matrix and fluid. The results of this study show the potential of cross-hole radar tomography methods to monitor the effects of steam-induced heating in fractured rock environments. ?? 2006 European Association of Geoscientists & Engineers.

  4. Characterization of Window Functions for Regularization of Electrical Capacitance Tomography Image Reconstruction

    NASA Astrophysics Data System (ADS)

    Jiang, Peng; Peng, Lihui; Xiao, Deyun

    2007-06-01

    This paper presents a regularization method by using different window functions as regularization for electrical capacitance tomography (ECT) image reconstruction. Image reconstruction for ECT is a typical ill-posed inverse problem. Because of the small singular values of the sensitivity matrix, the solution is sensitive to the measurement noise. The proposed method uses the spectral filtering properties of different window functions to make the solution stable by suppressing the noise in measurements. The window functions, such as the Hanning window, the cosine window and so on, are modified for ECT image reconstruction. Simulations with respect to five typical permittivity distributions are carried out. The reconstructions are better and some of the contours are clearer than the results from the Tikhonov regularization. Numerical results show that the feasibility of the image reconstruction algorithm using different window functions as regularization.

  5. How invasive is TMJ double-contrast arthrography in combination with cinematography? Patient discomfort versus known diagnostic gain.

    PubMed

    Engelke, W; Mommaerts, M

    1990-04-01

    There is no doubt that double-contrast TMJ fluoroscopic tomography enables a differential diagnosis and treatment in internal derangement pathosis. Its indication is, apart from the expected diagnostic gain, also determined by the degree of its invasiveness, and other alternative diagnostics being available (nuclear magnetic resonance). Data on patient discomfort and complications were gathered in 63 arthrotomographies; pain sensations and mandibular mobility, during and after the procedure in particular, were studied. We consider, along with Westesson, the procedure to be less invasive than commonly considered, once the surgeon-radiologist has gained enough experience.

  6. Vasodilator Stress Single-Photon Emission Computed Tomography or Contrast Stress Echocardiography Association with Hard Cardiac Events in Suspected Coronary Artery Disease.

    PubMed

    Gaibazzi, Nicola; Siniscalchi, Carmine; Porter, Thomas R; Crocamo, Antonio; Basaglia, Manuela; Boffetti, Francesca; Lorenzoni, Valentina

    2018-06-01

    We compared the long-term outcome of subjects without prior cardiac disease who underwent either vasodilator single-photon emission computed tomography (SPECT) or contrast stress-echocardiography (cSE) for suspected coronary artery disease (CAD). Subjects who underwent vasodilator SPECT or cSE between 2008 and 2012 for suspected CAD but no history of cardiac disease were included. We retrospectively compared the association of each method with combined all-cause death and nonfatal myocardial infarction and their positive predictive value (PPV) for angiographically obstructive CAD. A total of 1,387 subjects were selected: 497 who underwent SPECT and 890 who underwent cSE. During 4 years of mean follow-up there were 78 hard events in the cSE group and 51 in the SPECT group. Event-free survival in subjects testing positive for ischemia, either with SPECT or cSE, was significantly worse both in the overall population and after propensity matching patients. In multivariable analyses, vasodilator SPECT or cSE demonstrated significant stratification capability with an ischemic test doubling (SPECT) or more than doubling (cSE) the risk of future hard events independently from other variables. PPV of vasodilator SPECT for the diagnosis of obstructive CAD was inferior to vasodilator cSE (PPV = 63% vs 89%, respectively; P < .001). Our study suggests that the associations of vasodilator SPECT or cSE with outcome are comparable, with cSE demonstrating better diagnostic PPV for CAD. The absence of ionizing radiation and anticipated lower costs from higher PPV suggest that vasodilator cSE is a valid alternative to vasodilator SPECT as a gatekeeper in subjects without a prior history of CAD. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  7. Effects of Silexan on the Serotonin-1A Receptor and Microstructure of the Human Brain: A Randomized, Placebo-Controlled, Double-Blind, Cross-Over Study with Molecular and Structural Neuroimaging

    PubMed Central

    Baldinger, Pia; Höflich, Anna S.; Mitterhauser, Markus; Hahn, Andreas; Rami-Mark, Christina; Spies, Marie; Wadsak, Wolfgang; Lanzenberger, Rupert

    2015-01-01

    Background: Recently, Silexan, a patented active substance comprised of an essential oil produced from Lavandula angustifolia flowers, has been authorized in Germany as a medicinal product for the treatment of states of restlessness related to anxious mood. Its efficacy has been shown in several forms of anxiety disorders. Findings from preclinical and clinical studies attribute a major role to the serotonin-1A receptor in the pathogenesis and treatment of anxiety. Methods: To elucidate the effect of Silexan on serotonin-1A receptor binding, 17 healthy men underwent 2 positron emission tomography measurements using the radioligand [carbonyl-11C]WAY-100635 following the daily intake of 160mg Silexan or placebo for a minimum of 8 weeks (randomized, double-blind, cross-over design). Additionally, structural magnetic resonance imaging and voxel-based morphometry analysis was performed to determine potential effects on gray matter microstructure. Results: Serotonin-1A receptor binding potential was shown to be significantly reduced following the intake of Silexan compared with placebo in 2 large clusters encompassing the temporal gyrus, the fusiform gyrus and the hippocampus on one hand as well as the insula and anterior cingulate cortex on the other hand. No effects of Silexan on gray matter volume could be detected in this investigation. Conclusion: This positron emission tomography study proposes an involvement of the serotonin-1A receptor in the anxiolytic effects of Silexan. The study was registered in the International Standard Randomized Controlled Trial Number Register as ISRCTN30885829 (http://www.controlled-trials.com/isrctn/). PMID:25522403

  8. A novel method for NDT applications using NXCT system at the Missouri University of Science & Technology

    NASA Astrophysics Data System (ADS)

    Sinha, Vaibhav; Srivastava, Anjali; Koo Lee, Hyoung

    2014-06-01

    A novel method for non-destructive analysis has been developed using a neutron/X-ray combined computed tomography (NXCT) system at the Missouri University of Science and Technology Reactor (MSTR). This imaging system takes advantage of the fact that neutrons and X-rays have characteristically different interactions with same materials. NXCT fuses the imaging capabilities of both systems at one location and allows instant evaluation for nondestructive testing (NDT) applications. This technique promises viable advances in the field of NDT. In this paper, the complete design criteria and procedures are provided. The described design criteria and procedures can effectively be utilized to design and develop advanced combined computed tomography system. The successful operation of the high resolution X-ray and neutron computed tomography has been demonstrated in this paper. The utility and importance of the NXCT system has been shown by nondestructive evaluation of various phantoms constituting different materials, geometrical, structural and compositional information. The concept of NXCT can be useful for concealed material detection, material characterization, investigation of complex geometries involving different atomic number materials and real time imaging for in-situ studies.

  9. Assessment of human brown adipose tissue density during daily ingestion of thermogenic capsinoids using near-infrared time-resolved spectroscopy

    NASA Astrophysics Data System (ADS)

    Nirengi, Shinsuke; Homma, Toshiyuki; Inoue, Naohiko; Sato, Hitoshi; Yoneshiro, Takeshi; Matsushita, Mami; Kameya, Toshimitsu; Sugie, Hiroki; Tsuzaki, Kokoro; Saito, Masayuki; Sakane, Naoki; Kurosawa, Yuko; Hamaoka, Takafumi

    2016-09-01

    F18-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) is widely used as a standard method for evaluating human brown adipose tissue (BAT), a recognized therapeutic target of obesity. However, a longitudinal BAT study using FDG-PET/CT is lacking owing to limitations of the method. Near-infrared time-resolved spectroscopy (NIRTRS) is a technique for evaluating human BAT density noninvasively. This study aimed to test whether NIRTRS could detect changes in BAT density during or after long-term intervention. First, using FDG-PET/CT, we confirmed a significant increase (+48.8%, P<0.05) in BAT activity in the supraclavicular region after 6-week treatment with thermogenic capsaicin analogs, capsinoids. Next, 20 volunteers were administered either capsinoids or placebo daily for 8 weeks in a double-blind design, and BAT density was measured using NIRTRS every 2 weeks during the 8-week treatment period and an 8-week period after stopping treatment. Consistent with FDG-PET/CT results, NIRTRS successfully detected an increase in BAT density during the 8-week treatment (+46.4%, P<0.05), and a decrease in the 8-week follow-up period (-12.5%, P=0.07), only in the capsinoid-treated, but not the placebo, group. Thus, NIRTRS can be applied for quantitative assessment of BAT in longitudinal intervention studies in humans.

  10. Double-excitation fluorescence spectral imaging: eliminating tissue auto-fluorescence from in vivo PPIX measurements

    NASA Astrophysics Data System (ADS)

    Torosean, Sason; Flynn, Brendan; Samkoe, Kimberley S.; Davis, Scott C.; Gunn, Jason; Axelsson, Johan; Pogue, Brian W.

    2012-02-01

    An ultrasound coupled handheld-probe-based optical fluorescence molecular tomography (FMT) system has been in development for the purpose of quantifying the production of Protoporphyrin IX (PPIX) in aminolevulinic acid treated (ALA), Basal Cell Carcinoma (BCC) in vivo. The design couples fiber-based spectral sampling of PPIX fluorescence emission with a high frequency ultrasound imaging system, allowing regionally localized fluorescence intensities to be quantified [1]. The optical data are obtained by sequential excitation of the tissue with a 633nm laser, at four source locations and five parallel detections at each of the five interspersed detection locations. This method of acquisition permits fluorescence detection for both superficial and deep locations in ultrasound field. The optical boundary data, tissue layers segmented from ultrasound image and diffusion theory are used to estimate the fluorescence in tissue layers. To improve the recovery of the fluorescence signal of PPIX, eliminating tissue autofluorescence is of great importance. Here the approach was to utilize measurements which straddled the steep Qband excitation peak of PPIX, via the integration of an additional laser source, exciting at 637 nm; a wavelength with a 2 fold lower PPIX excitation value than 633nm.The auto-fluorescence spectrum acquired from the 637 nm laser is then used to spectrally decouple the fluorescence data and produce an accurate fluorescence emission signal, because the two wavelengths have very similar auto-fluorescence but substantially different PPIX excitation levels. The accuracy of this method, using a single source detector pair setup, is verified through animal tumor model experiments, and the result is compared to different methods of fluorescence signal recovery.

  11. Deformation and spallation of a magnesium alloy under high strain rate loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, M.; Lu, L.; Li, C.

    2016-04-01

    We investigate deformation and damage of a magnesium alloy, AZ91, under high strain rate (similar to 10(5) s(-1)) loading via planar impact. The soft-recovered specimens are examined with electron back-scatter diffraction (EBSD). EBSD analysis reveals three types of twinning: {1012} extension, {10 (1) over bar1} contraction, and {10 (1) over bar1}-{10 (1) over bar2) double twinning, and their number density increases with increasing impact velocity. The extension twins dominate contraction and double twins in size and number. Dislocation densities of the recovered specimens are evaluated with x-ray diffraction, and increase with increasing impact velocity. X-ray tomography is used to resolvemore » three-dimensional microstructure of shock-recovered samples. The EBSD and tomography results demonstrate that the second phase, Mg17Al12, plays an important role in both deformation twinning and tensile cracking. Deformation twinning appears to be a common mechanism in deformation of magnesium alloys at low, medium and high strain rates, in addition to dislocation motion. (C) 2016 Elsevier B.V. All rights reserved.« less

  12. Drug delivery monitoring by photoacoustic tomography with an ICG encapsulated double emulsion

    NASA Astrophysics Data System (ADS)

    Rajian, Justin Rajesh; Fabiilli, Mario L.; Fowlkes, J. Brian; Carson, Paul L.; Wang, Xueding

    2011-07-01

    The absorption spectrum of indocyanine green (ICG), a nontoxic dye used for medical diagnostics, depends upon its concentration as well as the nature of its environment, i.e., the solvent medium into which it is dissolved. In blood, ICG binds with plasma proteins, thus causing changes in its photoacoustic spectrum. We successfully encapsulated ICG in an ultrasound-triggerable perfluorocarbon double emulsion that prevents ICG from binding with plasma proteins. Photoacoustic spectral measurements on point target as well as 2-D photoacoustic images of blood vessels revealed that the photoacoustic spectrum changes significantly in blood when the ICG-loaded emulsion undergoes acoustic droplet vaporization (ADV), which is the conversion of liquid droplets into gas bubbles using ultrasound. We propose that these changes in the photoacoustic spectrum of the ICG emulsion in blood, coupled with photoacoustic tomography, could be used to spatially and quantitatively monitor ultrasound initiated drug delivery. In addition, we suggest that the photoacoustic spectral change induced by ultrasound exposure could also be used as contrast in photoacoustic imaging to obtain a background free image.

  13. [An ADAA model and its analysis method for agronomic traits based on the double-cross mating design].

    PubMed

    Xu, Z C; Zhu, J

    2000-01-01

    According to the double-cross mating design and using principles of Cockerham's general genetic model, a genetic model with additive, dominance and epistatic effects (ADAA model) was proposed for the analysis of agronomic traits. Components of genetic effects were derived for different generations. Monte Carlo simulation was conducted for analyzing the ADAA model and its reduced AD model by using different generations. It was indicated that genetic variance components could be estimated without bias by MINQUE(1) method and genetic effects could be predicted effectively by AUP method; at least three generations (including parent, F1 of single cross and F1 of double-cross) were necessary for analyzing the ADAA model and only two generations (including parent and F1 of double-cross) were enough for the reduced AD model. When epistatic effects were taken into account, a new approach for predicting the heterosis of agronomic traits of double-crosses was given on the basis of unbiased prediction of genotypic merits of parents and their crosses. In addition, genotype x environment interaction effects and interaction heterosis due to G x E interaction were discussed briefly.

  14. Simultaneous Neutron and X-ray Tomography for Quantitative analysis of Geological Samples

    NASA Astrophysics Data System (ADS)

    LaManna, J.; Hussey, D. S.; Baltic, E.; Jacobson, D. L.

    2016-12-01

    Multiphase flow is a critical area of research for shale gas, oil recovery, underground CO2 sequestration, geothermal power, and aquifer management. It is critical to understand the porous structure of the geological formations in addition to the fluid/pore and fluid/fluid interactions. Difficulties for analyzing flow characteristics of rock cores are in obtaining 3D distribution information on the fluid flow and maintaining the cores in a state for other analysis methods. Two powerful non-destructive methods for obtaining 3D structural and compositional information are X-ray and neutron tomography. X-ray tomography produces information on density and structure while neutrons excel at acquiring the liquid phase and produces compositional information. These two methods can offer strong complementary information but are typically conducted at separate times and often at different facilities. This poses issues for obtaining dynamic and stochastic information as the sample will change between analysis modes. To address this, NIST has developed a system that allows for multimodal, simultaneous tomography using thermal neutrons and X-rays by placing a 90 keVp micro-focus X-ray tube 90° to the neutron beam. High pressure core holders that simulate underground conditions have been developed to facilitate simultaneous tomography. These cells allow for the control of confining pressure, axial load, temperature, and fluid flow through the core. This talk will give an overview the simultaneous neutron and x-ray tomography capabilities at NIST, the benefits of multimodal imaging, environmental equipment for geology studies, and several case studies that have been conducted at NIST.

  15. A New Self-Constrained Inversion Method of Potential Fields Based on Probability Tomography

    NASA Astrophysics Data System (ADS)

    Sun, S.; Chen, C.; WANG, H.; Wang, Q.

    2014-12-01

    The self-constrained inversion method of potential fields uses a priori information self-extracted from potential field data. Differing from external a priori information, the self-extracted information are generally parameters derived exclusively from the analysis of the gravity and magnetic data (Paoletti et al., 2013). Here we develop a new self-constrained inversion method based on probability tomography. Probability tomography doesn't need any priori information, as well as large inversion matrix operations. Moreover, its result can describe the sources, especially the distribution of which is complex and irregular, entirely and clearly. Therefore, we attempt to use the a priori information extracted from the probability tomography results to constrain the inversion for physical properties. The magnetic anomaly data was taken as an example in this work. The probability tomography result of magnetic total field anomaly(ΔΤ) shows a smoother distribution than the anomalous source and cannot display the source edges exactly. However, the gradients of ΔΤ are with higher resolution than ΔΤ in their own direction, and this characteristic is also presented in their probability tomography results. So we use some rules to combine the probability tomography results of ∂ΔΤ⁄∂x, ∂ΔΤ⁄∂y and ∂ΔΤ⁄∂z into a new result which is used for extracting a priori information, and then incorporate the information into the model objective function as spatial weighting functions to invert the final magnetic susceptibility. Some magnetic synthetic examples incorporated with and without a priori information extracted from the probability tomography results were made to do comparison, results of which show that the former are more concentrated and with higher resolution of the source body edges. This method is finally applied in an iron mine in China with field measured ΔΤ data and performs well. ReferencesPaoletti, V., Ialongo, S., Florio, G., Fedi, M. & Cella, F., 2013. Self-constrained inversion of potential fields, Geophys J Int.This research is supported by the Fundamental Research Funds for Institute for Geophysical and Geochemical Exploration, Chinese Academy of Geological Sciences (Grant Nos. WHS201210 and WHS201211).

  16. Monotonicity-based electrical impedance tomography for lung imaging

    NASA Astrophysics Data System (ADS)

    Zhou, Liangdong; Harrach, Bastian; Seo, Jin Keun

    2018-04-01

    This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography (EIT). The EIT data (i.e. the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to the lung ventilation can be viewed as either semi-positive or semi-negative definite owing to monotonic conductivity changes within the lung regions. We used these monotonicity constraints to improve the quality of lung EIT imaging. We tested the proposed methods in numerical simulations, phantom experiments and human experiments.

  17. A Comprehensive Seismic Characterization of the Cove Fort-Sulphurdale Geothermal Site, Utah

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Li, J.; Zhang, X.; Liu, Y.; Kuleli, H. S.; Toksoz, M. N.

    2012-12-01

    The Cove Fort-Sulphurdale geothermal area is located in the transition zone between the extensional Basin and Range Province to the west and the uplifted Colorado Plateau to the east. The region around the geothermal site has the highest heat flow values of over 260 mWm-2 in Utah. To better understand the structure around the geothermal site, the MIT group deployed 10 seismic stations for a period of one year from August 2010. The local seismic network detected over 500 local earthquakes, from which ~200 events located within the network were selected for further analysis. Our seismic analysis is focused on three aspects: seismic velocity and attenuation tomography, seismic event focal mechanism analysis, and seismic shear wave splitting analysis. First P- and S-wave arrivals are picked manually and then the waveform cross-correlation technique is applied to obtain more accurate differential times between event pairs observed on common stations. The double-difference tomography method of Zhang and Thurber (2003) is used to simultaneously determine Vp and Vs models and seismic event locations. For the attenuation tomography, we first calculate t* values from spectrum fitting and then invert them to get Q models based on known velocity models and seismic event locations. Due to the limited station coverage and relatively low signal to noise ratio, many seismic waveforms do not have clear first P arrival polarities and as a result the conventional focal mechanism determination method relying on the polarity information is not applicable. Therefore, we used the full waveform matching method of Li et al. (2010) to determine event focal mechanisms. For the shear wave splitting analysis, we used the cross-correlation method to determine the delay times between fast and slow shear waves and the polarization angles of fast shear waves. The delay times are further taken to image the anisotropy percentage distribution in three dimensions using the shear wave splitting tomography method of Zhang et al. (2007). For the study region, overall the velocity is lower and attenuation is higher in the western part. Correspondingly, the anisotropy is also stronger, indicating the fractures may be more developed in the western part. The average fast polarization directions of fast shear waves at each station mostly point NNE. From the focal mechanism analysis from selected events, it shows that the normal faulting events have strikes in NNE direction, and the events with strike slip mechanism have strikes either parallel with the NNE trending faults or their conjugate ones. Assuming the maximum horizontal stress (SHmax) is parallel with the strike of the normal faulting events and bisects the two fault planes of the strike-slip events, the inverted source mechanism suggests a NNE oriented maximum horizontal stress regime. This area is under W-E tensional stress, which means maximum compressional stress should be in the N-E or NNE direction in general. The combination of shear wave splitting and focal mechanism analysis suggests that in this region the faults and fractures are aligned in the NNE direction.

  18. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    PubMed

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, <0.001 and 0.0002, respectively). When comparing measurement errors between stones of different composition in vitro, the error for calcium oxalate calculi was significantly different from the gold standard for all methods except bone window settings with magnification. For uric acid calculi the measurement error was observed only in standard soft tissue window settings. In vivo 4.0x magnified bone windows was superior to 4.0x magnified soft tissue windows in measurement accuracy. Magnified bone window measurements were not statistically different from digital caliper measurements (mean underestimation vs digital caliper 0.3 mm, p = 0.4), while magnified soft tissue windows were statistically distinct (mean underestimation 1.4 mm, p = 0.001). In this study magnified bone windows were the most accurate method of stone measurements in vitro and in vivo. Therefore, we recommend the routine use of magnified bone windows for computerized tomography measurement of stones. In vitro the measurement error in calcium oxalate stones was greater than that in uric acid stones, suggesting that stone composition may be responsible for measurement inaccuracies.

  19. In Situ Local Fracture Flow Measurement by the Double Packer Dilution Test

    NASA Astrophysics Data System (ADS)

    Englert, A.; Le Borgne, T.; Bour, O.; Klepikova, M.; Lavenant, N.

    2011-12-01

    For prediction of flow and transport in fractured media, prior estimation of the fracture network is essential, but challenging. Recent developments in hydraulic tomography have shown promising results for understanding connectivities between boreholes. However, as the hydraulic tomographic survey is typically based on the propagation of head only, it becomes a strongly non unique problem. To reduce the non uniqueness of tomographic surveys point conditioning has been found beneficial. Just as well, measurement of local flow in a fracture can serve as point conditioning for hydraulic and tracer tomographic surveys. Nevertheless, only few measurements of local fracture flow have been performed since this type of measurements implies several important technical issues. Dilution test in a packed off interval is a possible method for measuring fracture flow (e.g. Drost et al. 1968, Novakowski et al., 2005). However, a key issue for estimating flow with dilution tests is to ensure a full mixing of the tracer in the packed interval. This is typically done by including a mixing system within the packer. The design of such system can be challenging for deep wells and small diameters. Here, we propose a method where mixing is ensured by a recirculation loop including a surface tank. This method is adapted from the design proposed by Brouyere et al. (2008), who measured dilution in open wells. Dilution is quantified by measuring the concentration in the surface barrel as function of time. Together with the measurement of the circulating flow and the water filled volume in the surface barrel, the measured tracer dilution allows for calculation of the fracture flow. Since the method can be applied using a classical double packer system, it may provide a broader application of local flow measurements in heterogeneous media. We tested the approach on the Ploemeur fractured crystalline rock site. A one meter interval at depth 80 m with a single flowing fracture was isolated with a double packer dilution system. We performed a pumping test in the adjacent well. Different flow rates were estimated from the dilution curves for the different pumping rates in the adjacent well, showing a linear response. The obtained fracture flow rates provide important information on the flow geometry and connectivity between the two wells. Future joint interpretation of flow measurements, hydraulic head and tracer test data is expected to provide detailed insights in the flow and transport processes at the Ploemeur site. Drost, W., Klotz, D., Koch, A., Moser, H., Neumaier, F., Rauert, W.: Point dilution methods of investigating ground water flow by means of radioisotopes, Water. Resour. Res., 4(1), 1968. Novakowski, K., Bickerton, G., Lapcevic, P., Voralek, J., Ross, N.: Measurements of groundwater velocity in discrete rock fractures: Jour. Cont. Hydr., 82(1-2), 2006. Brouyere, S., Batlle-Aguilar, J., Goderniaux, P., Dassargues, A.: A new tracer technique for monitoring groundwater fluxes: The Finite Volume Point Dilution Method, Jour. Cont. Hydr., 95(3-4), 121-140, 2008.

  20. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography.

    PubMed

    Carlier, Stéphane; Didday, Rich; Slots, Tristan; Kayaert, Peter; Sonck, Jeroen; El-Mourad, Mike; Preumont, Nicolas; Schoors, Dany; Van Camp, Guy

    2014-06-01

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator's identification of landmarks to establish the image synchronization. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. STEM-EDX tomography of bimetallic nanoparticles: A methodological investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slater, Thomas J. A.; Janssen, Arne; Camargo, Pedro H. C.

    This paper presents an investigation of the limitations and optimization of energy dispersive X-ray (EDX) tomography within the scanning transmission electron microscope, focussing on application of the technique to characterising the 3D elemental distribution of bimetallic AgAu nanoparticles. The detector collection efficiency when using a standard tomography holder is characterised using a tomographic data set from a single nanoparticle and compared to a standard low background double tilt holder. Optical depth profiling is used to investigate the angles and origin of detector shadowing as a function of specimen field of view. A novel time-varied acquisition scheme is described to compensatemore » for variations in the intensity of spectrum images at each sample tilt. Lastly, the ability of EDX spectrum images to satisfy the projection requirement for nanoparticle samples is discussed, with consideration of the effect of absorption and shadowing variations« less

  2. STEM-EDX tomography of bimetallic nanoparticles: A methodological investigation

    DOE PAGES

    Slater, Thomas J. A.; Janssen, Arne; Camargo, Pedro H. C.; ...

    2015-10-22

    This paper presents an investigation of the limitations and optimization of energy dispersive X-ray (EDX) tomography within the scanning transmission electron microscope, focussing on application of the technique to characterising the 3D elemental distribution of bimetallic AgAu nanoparticles. The detector collection efficiency when using a standard tomography holder is characterised using a tomographic data set from a single nanoparticle and compared to a standard low background double tilt holder. Optical depth profiling is used to investigate the angles and origin of detector shadowing as a function of specimen field of view. A novel time-varied acquisition scheme is described to compensatemore » for variations in the intensity of spectrum images at each sample tilt. Lastly, the ability of EDX spectrum images to satisfy the projection requirement for nanoparticle samples is discussed, with consideration of the effect of absorption and shadowing variations« less

  3. Cryptococcus gattii Infection Presenting as an Aggressive Lung Mass.

    PubMed

    Zheng, Shuwei; Tan, Thuan Tong; Chien, Jaime Mei Fong

    2018-06-01

    Cryptococcus gattii is an endemic fungus predominantly isolated in the tropical and subtropical regions, causing predominantly pulmonary disease with a predilection for the central nervous system. Herein, we report a case of rapidly progressing C. gattii pneumonia in an immune-deficient but virologically suppressed host with underlying human immunodeficiency viral (HIV) infection, exhibiting various fungal morphologies from bronchoalveolar lavage (BAL) cytological specimens. A 51-year-old Chinese male with known HIV disease was admitted to the Singapore General Hospital for evaluation of functional decline, febrile episodes, and a left hilar mass on chest radiograph. Computed tomography (CT) showed consolidation in the apical segment of the left lower lobe. He underwent bronchoscopy and BAL. Positron emission tomography-computed tomography done 10 days after the initial CT showed approximate doubling of the pulmonary lesion. Cytological examination of the fluid revealed yeasts of varying sizes. Subsequent fungal culture from BAL fluid grew C. gattii 10 days later.

  4. Microwave-driven coherent operation of a semiconductor quantum dot charge qubit

    DOE PAGES

    Kim, Dohun; Ward, D. R.; Simmons, C. B.; ...

    2015-02-16

    An intuitive realization of a qubit is an electron charge at two well-defined positions of a double quantum dot. The qubit is simple and has the potential for high-speed operation because of its strong coupling to electric fields. But, charge noise also couples strongly to this qubit, resulting in rapid dephasing at all but one special operating point called the ‘sweet spot’. In previous studies d.c. voltage pulses have been used to manipulate semiconductor charge qubits but did not achieve high-fidelity control, because d.c. gating requires excursions away from the sweet spot. Here, by using resonant a.c. microwave driving wemore » achieve fast (greater than gigahertz) and universal single qubit rotations of a semiconductor charge qubit. The Z-axis rotations of the qubit are well protected at the sweet spot, and we demonstrate the same protection for rotations about arbitrary axes in the X–Y plane of the qubit Bloch sphere. We characterize the qubit operation using two tomographic approaches: standard process tomography and gate set tomography. Moreover, both methods consistently yield process fidelities greater than 86% with respect to a universal set of unitary single-qubit operations.« less

  5. Quantum beats in conductance oscillations in graphene-based asymmetric double velocity wells and electrostatic wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Lei; Department of Medical Physics, Basic Medical College, Hebei Medical University, Shijiazhuang, Hebei 050017; Li, Yu-Xian

    2014-01-14

    The transport properties in graphene-based asymmetric double velocity well (Fermi velocity inside the well less than that outside the well) and electrostatic well structures are investigated using the transfer matrix method. The results show that quantum beats occur in the oscillations of the conductance for asymmetric double velocity wells. The beating effect can also be found in asymmetric double electrostatic wells, but only if the widths of the two wells are different. The beat frequency for the asymmetric double well is exactly equal to the frequency difference between the oscillation rates in two isolated single wells with the same structuresmore » as the individual wells in the double well structure. A qualitative interpretation is proposed based on the fact that the resonant levels depend upon the sizes of the quantum wells. The beating behavior can provide a new way to identify the symmetry of double well structures.« less

  6. Simultaneous maximum a posteriori longitudinal PET image reconstruction

    NASA Astrophysics Data System (ADS)

    Ellis, Sam; Reader, Andrew J.

    2017-09-01

    Positron emission tomography (PET) is frequently used to monitor functional changes that occur over extended time scales, for example in longitudinal oncology PET protocols that include routine clinical follow-up scans to assess the efficacy of a course of treatment. In these contexts PET datasets are currently reconstructed into images using single-dataset reconstruction methods. Inspired by recently proposed joint PET-MR reconstruction methods, we propose to reconstruct longitudinal datasets simultaneously by using a joint penalty term in order to exploit the high degree of similarity between longitudinal images. We achieved this by penalising voxel-wise differences between pairs of longitudinal PET images in a one-step-late maximum a posteriori (MAP) fashion, resulting in the MAP simultaneous longitudinal reconstruction (SLR) method. The proposed method reduced reconstruction errors and visually improved images relative to standard maximum likelihood expectation-maximisation (ML-EM) in simulated 2D longitudinal brain tumour scans. In reconstructions of split real 3D data with inserted simulated tumours, noise across images reconstructed with MAP-SLR was reduced to levels equivalent to doubling the number of detected counts when using ML-EM. Furthermore, quantification of tumour activities was largely preserved over a variety of longitudinal tumour changes, including changes in size and activity, with larger changes inducing larger biases relative to standard ML-EM reconstructions. Similar improvements were observed for a range of counts levels, demonstrating the robustness of the method when used with a single penalty strength. The results suggest that longitudinal regularisation is a simple but effective method of improving reconstructed PET images without using resolution degrading priors.

  7. Force estimation from OCT volumes using 3D CNNs.

    PubMed

    Gessert, Nils; Beringhoff, Jens; Otte, Christoph; Schlaefer, Alexander

    2018-07-01

    Estimating the interaction forces of instruments and tissue is of interest, particularly to provide haptic feedback during robot-assisted minimally invasive interventions. Different approaches based on external and integrated force sensors have been proposed. These are hampered by friction, sensor size, and sterilizability. We investigate a novel approach to estimate the force vector directly from optical coherence tomography image volumes. We introduce a novel Siamese 3D CNN architecture. The network takes an undeformed reference volume and a deformed sample volume as an input and outputs the three components of the force vector. We employ a deep residual architecture with bottlenecks for increased efficiency. We compare the Siamese approach to methods using difference volumes and two-dimensional projections. Data were generated using a robotic setup to obtain ground-truth force vectors for silicon tissue phantoms as well as porcine tissue. Our method achieves a mean average error of [Formula: see text] when estimating the force vector. Our novel Siamese 3D CNN architecture outperforms single-path methods that achieve a mean average error of [Formula: see text]. Moreover, the use of volume data leads to significantly higher performance compared to processing only surface information which achieves a mean average error of [Formula: see text]. Based on the tissue dataset, our methods shows good generalization in between different subjects. We propose a novel image-based force estimation method using optical coherence tomography. We illustrate that capturing the deformation of subsurface structures substantially improves force estimation. Our approach can provide accurate force estimates in surgical setups when using intraoperative optical coherence tomography.

  8. Assessment of six different collagenase-based methods to isolate feline pancreatic islets.

    PubMed

    Zini, Eric; Franchini, Marco; Guscetti, Franco; Osto, Melania; Kaufmann, Karin; Ackermann, Mathias; Lutz, Thomas A; Reusch, Claudia E

    2009-12-01

    Isolation of pancreatic islets is necessary to study the molecular mechanisms underlying beta-cell demise in diabetic cats. Six collagenase-based methods of isolation were compared in 10 cat pancreata, including single and double course of collagenase, followed or not by Ficoll centrifugation or accutase, and collagenase plus accutase. Morphometric analysis was performed to measure the relative area of islet and exocrine tissue. Islet specific mRNA transcripts were quantified in isolates by real-time PCR. The single and double course of collagenase digestion was successful in each cat and provided similar islet-to-exocrine tissue ratio. Quantities of insulin mRNA did not differ between the two methods. However, on histological examination either method yielded only approximately 2% of pure islets. The other methods provided disrupted islets or insufficient samples in 1-7 cats. Although pancreas digestion with single and double course of collagenase was superior, further studies are needed to improve islet isolation in cats.

  9. Double versus single cervical cerclage for patients with recurrent pregnancy loss: a randomized clinical trial.

    PubMed

    Zolghadri, Jaleh; Younesi, Masoumeh; Asadi, Nasrin; Khosravi, Dezire; Behdin, Shabnam; Tavana, Zohre; Ghaffarpasand, Fariborz

    2014-02-01

    To compare the effectiveness of the double cervical cerclage method versus the single method in women with recurrent second-trimester delivery. In this randomized clinical trial, we included 33 singleton pregnancies suffering from recurrent second-trimester pregnancy loss (≥2 consecutive fetal loss during second-trimester or with a history of unsuccessful procedures utilizing the McDonald method), due to cervical incompetence. Patients were randomly assigned to undergo either the classic McDonald method (n = 14) or the double cerclage method (n = 19). The successful pregnancy rate and gestational age at delivery was also compared between the two groups. The two study groups were comparable regarding their baseline characteristics. The successful pregnancy rate did not differ significantly between those who underwent the double cerclage method or the classic McDonald cerclage method (100% vs 85.7%; P = 0.172). In the same way, the preterm delivery rate (<34 weeks of gestation) was comparable between the two study groups (10.5% vs 35.7%; P = 0.106). Those undergoing the double cerclage method had longer gestational duration (37.2 ± 2.6 vs 34.3 ± 3.8 weeks; P = 0.016). The double cervical cerclage method seems to provide better cervical support, as compared with the classic McDonald cerclage method, in those suffering from recurrent pregnancy loss, due to cervical incompetence. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.

  10. Room temperature synthesis of water-dispersible Ln3+:CeF3 (Ln = Nd, Tb) nanoparticles with different morphology as bimodal probes for fluorescence and CT imaging.

    PubMed

    González-Mancebo, Daniel; Becerro, Ana I; Rojas, T Cristina; Olivencia, Andrés; Corral, Ariadna; Balcerzyk, Marcin; Cantelar, Eugenio; Cussó, Fernando; Ocaña, Manuel

    2018-06-15

    The singular properties of lanthanide-based inorganic nanoparticles (NPs) has raised the attention of the scientific community in biotechnological applications. In particular, those systems with two or more functionalities are especially interesting. In this work, an effective and commercially attractive procedure has been developed that renders uniform, water-dispersible Ln 3+ :CeF 3 (Ln = Tb, Nd) NPs with different shapes and size. The method consists of the homogeneous precipitation, in a mixture of polyol and water, of cations and anions using precursors that allow the controlled release of the latter. The advantages of the reported method are related to the absence of surfactants, dispersing agents or corrosive precursors as well as to the room temperature of the process. The obtained Tb:CeF 3 NPs produce an intense emission after excitation through the Ce-Tb energy transfer band located in the UV spectral region, thus being potentially useful as phosphors for in-vitro imaging purposes. On the other hand, the synthesized Nd:CeF 3 NPs are good candidates for in-vivo imaging because their excitation and emission wavelengths lie in the biological windows. Finally, the excellent X-ray attenuation efficacy of the Nd:CeF 3 NPs is shown, which confers double functionality to this material as both luminescence bioprobe and contrast agent for X-ray computed-tomography. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. The feasibility of using microwave-induced thermoacoustic tomography for detection and evaluation of renal calculi.

    PubMed

    Cao, Caijun; Nie, Liming; Lou, Cunguang; Xing, Da

    2010-09-07

    Imaging of renal calculi is important for patients who suffered a urinary calculus prior to treatment. The available imaging techniques include plain x-ray, ultrasound scan, intravenous urogram, computed tomography, etc. However, the visualization of a uric acid calculus (radiolucent calculi) is difficult and often impossible by the above imaging methods. In this paper, a new detection method based on microwave-induced thermoacoustic tomography was developed to detect the renal calculi. Thermoacoustic images of calcium oxalate and uric acid calculus were compared with their x-ray images. The microwave absorption differences among the calcium oxalate calculus, uric acid calculus and normal kidney tissue could be evaluated by the amplitude of the thermoacoustic signals. The calculi hidden in the swine kidney were clearly imaged with excellent contrast and resolution in the three orthogonal thermoacoustic images. The results indicate that thermoacoustic imaging may be developed as a complementary method for detecting renal calculi, and its low cost and effective feature shows high potential for clinical applications.

  12. In-vivo, real-time cross-sectional images of retina using a GPU enhanced master slave optical coherence tomography system

    NASA Astrophysics Data System (ADS)

    Bradu, Adrian; Kapinchev, Konstantin; Barnes, Frederick; Podoleanu, Adrian

    2016-03-01

    In our previous reports we demonstrated a novel Fourier domain optical coherence tomography method, Master Slave optical coherence tomography (MS-OCT), that does not require resampling of data and can deliver en-face images from several depths simultaneously. While ideally suited for delivering information from a selected depth, the MS-OCT has been so far inferior to the conventional FFT based OCT in terms of time of producing cross section images. Here, we demonstrate that by taking advantage of the parallel processing capabilities offered by the MS-OCT method, cross-sectional OCT images of the human retina can be produced in real-time by assembling several T-scans from different depths. We analyze the conditions that ensure a real-time B-scan imaging operation, and demonstrate in-vivo real-time images from human fovea and the optic nerve, of comparable resolution and sensitivity to those produced using the traditional Fourier domain based method.

  13. 3D first-arrival traveltime tomography with modified total variation regularization

    NASA Astrophysics Data System (ADS)

    Jiang, Wenbin; Zhang, Jie

    2018-02-01

    Three-dimensional (3D) seismic surveys have become a major tool in the exploration and exploitation of hydrocarbons. 3D seismic first-arrival traveltime tomography is a robust method for near-surface velocity estimation. A common approach for stabilizing the ill-posed inverse problem is to apply Tikhonov regularization to the inversion. However, the Tikhonov regularization method recovers smooth local structures while blurring the sharp features in the model solution. We present a 3D first-arrival traveltime tomography method with modified total variation (MTV) regularization to preserve sharp velocity contrasts and improve the accuracy of velocity inversion. To solve the minimization problem of the new traveltime tomography method, we decouple the original optimization problem into two following subproblems: a standard traveltime tomography problem with the traditional Tikhonov regularization and a L2 total variation problem. We apply the conjugate gradient method and split-Bregman iterative method to solve these two subproblems, respectively. Our synthetic examples show that the new method produces higher resolution models than the conventional traveltime tomography with Tikhonov regularization. We apply the technique to field data. The stacking section shows significant improvements with static corrections from the MTV traveltime tomography.

  14. Three-dimensional structural dynamics and fluctuations of DNA-nanogold conjugates by individual-particle electron tomography

    DOE PAGES

    Zhang, Lei; Lei, Dongsheng; Smith, Jessica M.; ...

    2016-03-30

    DNA base pairing has been used for many years to direct the arrangement of inorganic nanocrystals into small groupings and arrays with tailored optical and electrical properties. The control of DNA-mediated assembly depends crucially on a better understanding of three-dimensional structure of DNA-nanocrystal-hybridized building blocks. Existing techniques do not allow for structural determination of these flexible and heterogeneous samples. Here we report cryo-electron microscopy and negative-staining electron tomography approaches to image, and three-dimensionally reconstruct a single DNA-nanogold conjugate, an 84-bp double-stranded DNA with two 5-nm nanogold particles for potential substrates in plasmon-coupling experiments. By individual-particle electron tomography reconstruction, we obtainmore » 14 density maps at ~ 2-nm resolution . Using these maps as constraints, we derive 14 conformations of dsDNA by molecular dynamics simulations. The conformational variation is consistent with that from liquid solution, suggesting that individual-particle electron tomography could be an expected approach to study DNA-assembling and flexible protein structure and dynamics.« less

  15. Double-input compartmental modeling and spectral analysis for the quantification of positron emission tomography data in oncology.

    PubMed

    Tomasi, G; Kimberley, S; Rosso, L; Aboagye, E; Turkheimer, F

    2012-04-07

    In positron emission tomography (PET) studies involving organs different from the brain, ignoring the metabolite contribution to the tissue time-activity curves (TAC), as in the standard single-input (SI) models, may compromise the accuracy of the estimated parameters. We employed here double-input (DI) compartmental modeling (CM), previously used for [¹¹C]thymidine, and a novel DI spectral analysis (SA) approach on the tracers 5-[¹⁸F]fluorouracil (5-[¹⁸F]FU) and [¹⁸F]fluorothymidine ([¹⁸F]FLT). CM and SA were performed initially with a SI approach using the parent plasma TAC as an input function. These methods were then employed using a DI approach with the metabolite plasma TAC as an additional input function. Regions of interest (ROIs) corresponding to healthy liver, kidneys and liver metastases for 5-[¹⁸F]FU and to tumor, vertebra and liver for [¹⁸F]FLT were analyzed. For 5-[¹⁸F]FU, the improvement of the fit quality with the DI approaches was remarkable; in CM, the Akaike information criterion (AIC) always selected the DI over the SI model. Volume of distribution estimates obtained with DI CM and DI SA were in excellent agreement, for both parent 5-[¹⁸F]FU (R(2) = 0.91) and metabolite [¹⁸F]FBAL (R(2) = 0.99). For [¹⁸F]FLT, the DI methods provided notable improvements but less substantial than for 5-[¹⁸F]FU due to the lower rate of metabolism of [¹⁸F]FLT. On the basis of the AIC values, agreement between [¹⁸F]FLT K(i) estimated with the SI and DI models was good (R² = 0.75) for the ROIs where the metabolite contribution was negligible, indicating that the additional input did not bias the parent tracer only-related estimates. When the AIC suggested a substantial contribution of the metabolite [¹⁸F]FLT-glucuronide, on the other hand, the change in the parent tracer only-related parameters was significant (R² = 0.33 for K(i)). Our results indicated that improvements of DI over SI approaches can range from moderate to substantial and are more significant for tracers with a high rate of metabolism. Furthermore, they showed that SA is suitable for DI modeling and can be used effectively in the analysis of PET data.

  16. HT2DINV: A 2D forward and inverse code for steady-state and transient hydraulic tomography problems

    NASA Astrophysics Data System (ADS)

    Soueid Ahmed, A.; Jardani, A.; Revil, A.; Dupont, J. P.

    2015-12-01

    Hydraulic tomography is a technique used to characterize the spatial heterogeneities of storativity and transmissivity fields. The responses of an aquifer to a source of hydraulic stimulations are used to recover the features of the estimated fields using inverse techniques. We developed a 2D free source Matlab package for performing hydraulic tomography analysis in steady state and transient regimes. The package uses the finite elements method to solve the ground water flow equation for simple or complex geometries accounting for the anisotropy of the material properties. The inverse problem is based on implementing the geostatistical quasi-linear approach of Kitanidis combined with the adjoint-state method to compute the required sensitivity matrices. For undetermined inverse problems, the adjoint-state method provides a faster and more accurate approach for the evaluation of sensitivity matrices compared with the finite differences method. Our methodology is organized in a way that permits the end-user to activate parallel computing in order to reduce the computational burden. Three case studies are investigated demonstrating the robustness and efficiency of our approach for inverting hydraulic parameters.

  17. Retrospective respiration-gated whole-body photoacoustic computed tomography of mice

    NASA Astrophysics Data System (ADS)

    Xia, Jun; Chen, Wanyi; Maslov, Konstantin; Anastasio, Mark A.; Wang, Lihong V.

    2014-01-01

    Photoacoustic tomography (PAT) is an emerging technique that has a great potential for preclinical whole-body imaging. To date, most whole-body PAT systems require multiple laser shots to generate one cross-sectional image, yielding a frame rate of <1 Hz. Because a mouse breathes at up to 3 Hz, without proper gating mechanisms, acquired images are susceptible to motion artifacts. Here, we introduce, for the first time to our knowledge, retrospective respiratory gating for whole-body photoacoustic computed tomography. This new method involves simultaneous capturing of the animal's respiratory waveform during photoacoustic data acquisition. The recorded photoacoustic signals are sorted and clustered according to the respiratory phase, and an image of the animal at each respiratory phase is reconstructed subsequently from the corresponding cluster. The new method was tested in a ring-shaped confocal photoacoustic computed tomography system with a hardware-limited frame rate of 0.625 Hz. After respiratory gating, we observed sharper vascular and anatomical images at different positions of the animal body. The entire breathing cycle can also be visualized at 20 frames/cycle.

  18. Optical characterization of pancreatic normal and tumor tissues with double integrating sphere system

    NASA Astrophysics Data System (ADS)

    Kiris, Tugba; Akbulut, Saadet; Kiris, Aysenur; Gucin, Zuhal; Karatepe, Oguzhan; Bölükbasi Ates, Gamze; Tabakoǧlu, Haşim Özgür

    2015-03-01

    In order to develop minimally invasive, fast and precise diagnostic and therapeutic methods in medicine by using optical methods, first step is to examine how the light propagates, scatters and transmitted through medium. So as to find out appropriate wavelengths, it is required to correctly determine the optical properties of tissues. The aim of this study is to measure the optical properties of both cancerous and normal ex-vivo pancreatic tissues. Results will be compared to detect how cancerous and normal tissues respond to different wavelengths. Double-integrating-sphere system and computational technique inverse adding doubling method (IAD) were used in the study. Absorption and reduced scattering coefficients of normal and cancerous pancreatic tissues have been measured within the range of 500-650 nm. Statistical significant differences between cancerous and normal tissues have been obtained at 550 nm and 630 nm for absorption coefficients. On the other hand; there were no statistical difference found for scattering coefficients at any wavelength.

  19. Comparative study of cranial anthropometric measurement by traditional calipers to computed tomography and three-dimensional photogrammetry.

    PubMed

    Mendonca, Derick A; Naidoo, Sybill D; Skolnick, Gary; Skladman, Rachel; Woo, Albert S

    2013-07-01

    Craniofacial anthropometry by direct caliper measurements is a common method of quantifying the morphology of the cranial vault. New digital imaging modalities including computed tomography and three-dimensional photogrammetry are similarly being used to obtain craniofacial surface measurements. This study sought to compare the accuracy of anthropometric measurements obtained by calipers versus 2 methods of digital imaging.Standard anterior-posterior, biparietal, and cranial index measurements were directly obtained on 19 participants with an age range of 1 to 20 months. Computed tomographic scans and three-dimensional photographs were both obtained on each child within 2 weeks of the clinical examination. Two analysts measured the anterior-posterior and biparietal distances on the digital images. Measures of reliability and bias between the modalities were calculated and compared.Caliper measurements were found to underestimate the anterior-posterior and biparietal distances as compared with those of the computed tomography and the three-dimensional photogrammetry (P < 0.001). Cranial index measurements between the computed tomography and the calipers differed by up to 6%. The difference between the 2 modalities was statistically significant (P = 0.021). The biparietal and cranial index results were similar between the digital modalities, but the anterior-posterior measurement was greater with the three-dimensional photogrammetry (P = 0.002). The coefficients of variation for repeated measures based on the computed tomography and the three-dimensional photogrammetry were 0.008 and 0.007, respectively.In conclusion, measurements based on digital modalities are generally reliable and interchangeable. Caliper measurements lead to underestimation of anterior-posterior and biparietal values compared with digital imaging.

  20. WHOLE BODY NONRIGID CT-PET REGISTRATION USING WEIGHTED DEMONS.

    PubMed

    Suh, J W; Kwon, Oh-K; Scheinost, D; Sinusas, A J; Cline, Gary W; Papademetris, X

    2011-03-30

    We present a new registration method for whole-body rat computed tomography (CT) image and positron emission tomography (PET) images using a weighted demons algorithm. The CT and PET images are acquired in separate scanners at different times and the inherent differences in the imaging protocols produced significant nonrigid changes between the two acquisitions in addition to heterogeneous image characteristics. In this situation, we utilized both the transmission-PET and the emission-PET images in the deformable registration process emphasizing particular regions of the moving transmission-PET image using the emission-PET image. We validated our results with nine rat image sets using M-Hausdorff distance similarity measure. We demonstrate improved performance compared to standard methods such as Demons and normalized mutual information-based non-rigid FFD registration.

  1. A convolutional neural network approach to calibrating the rotation axis for X-ray computed tomography.

    PubMed

    Yang, Xiaogang; De Carlo, Francesco; Phatak, Charudatta; Gürsoy, Dogˇa

    2017-03-01

    This paper presents an algorithm to calibrate the center-of-rotation for X-ray tomography by using a machine learning approach, the Convolutional Neural Network (CNN). The algorithm shows excellent accuracy from the evaluation of synthetic data with various noise ratios. It is further validated with experimental data of four different shale samples measured at the Advanced Photon Source and at the Swiss Light Source. The results are as good as those determined by visual inspection and show better robustness than conventional methods. CNN has also great potential for reducing or removing other artifacts caused by instrument instability, detector non-linearity, etc. An open-source toolbox, which integrates the CNN methods described in this paper, is freely available through GitHub at tomography/xlearn and can be easily integrated into existing computational pipelines available at various synchrotron facilities. Source code, documentation and information on how to contribute are also provided.

  2. Solving the forward problem of magnetoacoustic tomography with magnetic induction by means of the finite element method

    NASA Astrophysics Data System (ADS)

    Li, Xun; Li, Xu; Zhu, Shanan; He, Bin

    2009-05-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently proposed imaging modality to image the electrical impedance of biological tissue. It combines the good contrast of electrical impedance tomography with the high spatial resolution of sonography. In this paper, a three-dimensional MAT-MI forward problem was investigated using the finite element method (FEM). The corresponding FEM formulae describing the forward problem are introduced. In the finite element analysis, magnetic induction in an object with conductivity values close to biological tissues was first carried out. The stimulating magnetic field was simulated as that generated from a three-dimensional coil. The corresponding acoustic source and field were then simulated. Computer simulation studies were conducted using both concentric and eccentric spherical conductivity models with different geometric specifications. In addition, the grid size for finite element analysis was evaluated for the model calibration and evaluation of the corresponding acoustic field.

  3. Solving the Forward Problem of Magnetoacoustic Tomography with Magnetic Induction by Means of the Finite Element Method

    PubMed Central

    Li, Xun; Li, Xu; Zhu, Shanan; He, Bin

    2010-01-01

    Magnetoacoustic Tomography with Magnetic Induction (MAT-MI) is a recently proposed imaging modality to image the electrical impedance of biological tissue. It combines the good contrast of electrical impedance tomography with the high spatial resolution of sonography. In this paper, three-dimensional MAT-MI forward problem was investigated using the finite element method (FEM). The corresponding FEM formulas describing the forward problem are introduced. In the finite element analysis, magnetic induction in an object with conductivity values close to biological tissues was first carried out. The stimulating magnetic field was simulated as that generated from a three-dimensional coil. The corresponding acoustic source and field were then simulated. Computer simulation studies were conducted using both concentric and eccentric spherical conductivity models with different geometric specifications. In addition, the grid size for finite element analysis was evaluated for model calibration and evaluation of the corresponding acoustic field. PMID:19351978

  4. Bilastine vs. hydroxyzine: occupation of brain histamine H1-receptors evaluated by positron emission tomography in healthy volunteers

    PubMed Central

    Farré, Magí; Pérez-Mañá, Clara; Papaseit, Esther; Menoyo, Esther; Pérez, Marta; Martin, Soraya; Bullich, Santiago; Rojas, Santiago; Herance, José-Raúl; Trampal, Carlos; Labeaga, Luis; Valiente, Román

    2014-01-01

    Aim A close correlation exists between positron emission tomography (PET)-determined histamine H1-receptor occupancy (H1RO) and the incidence of sedation. Antihistamines with H1RO <20% are classified as non-sedating. The objective was to compare the H1RO of bilastine, a second generation antihistamine, with that of hydroxyzine. Methods This randomized, double-blind, crossover study used PET imaging with [11C]-doxepin to evaluate H1RO in 12 healthy males (mean age 26.2 years), after single oral administration of bilastine (20 mg), hydroxyzine (25 mg) or placebo. Binding potentials and H1ROs were calculated in five cerebral cortex regions of interest: frontal, occipital, parietal, temporal, insula. Plasma bilastine concentrations, subjective sedation (visual analogue scale), objective psychomotor performance (digital symbol substitution test), physiological variables and safety (adverse events, AEs), were also evaluated. Results The mean binding potential of all five regions of interest (total binding potential) was significantly greater with bilastine than hydroxyzine (mean value 0.26 vs. 0.13, P < 0.01; mean difference and 95% CI −0.130 [−0.155, 0.105]). There was no significant difference between bilastine and placebo. Overall H1RO by bilastine was significantly lower than that by hydroxyzine (mean value −3.92% vs. 53.95%, P < 0.01; mean difference and 95% CI 57.870% [42.664%, 73.075%]). There was no significant linear relationship between individual bilastine plasma concentrations and total binding potential values. No significant between-treatment differences were observed for sedation and psychomotor performance. Twenty-six non-serious AEs were reported. Sleepiness or sedation was not reported with bilastine but appeared in some subjects with hydroxyzine. Conclusions A single oral dose of bilastine 20 mg had minimal H1RO, was not associated with subjective sedation or objective impairment of psychomotor performance and was devoid of treatment-related sedative AEs, thus satisfying relevant subjective, objective and PET criteria as a non-sedating antihistamine. PMID:24833043

  5. Combined measurement system for double shield tunnel boring machine guidance based on optical and visual methods.

    PubMed

    Lin, Jiarui; Gao, Kai; Gao, Yang; Wang, Zheng

    2017-10-01

    In order to detect the position of the cutting shield at the head of a double shield tunnel boring machine (TBM) during the excavation, this paper develops a combined measurement system which is mainly composed of several optical feature points, a monocular vision sensor, a laser target sensor, and a total station. The different elements of the combined system are mounted on the TBM in suitable sequence, and the position of the cutting shield in the reference total station frame is determined by coordinate transformations. Subsequently, the structure of the feature points and matching technique for them are expounded, the position measurement method based on monocular vision is presented, and the calibration methods for the unknown relationships among different parts of the system are proposed. Finally, a set of experimental platforms to simulate the double shield TBM is established, and accuracy verification experiments are conducted. Experimental results show that the mean deviation of the system is 6.8 mm, which satisfies the requirements of double shield TBM guidance.

  6. Preliminary frequency-domain analysis for the reconstructed spatial resolution of muon tomography

    NASA Astrophysics Data System (ADS)

    Yu, B.; Zhao, Z.; Wang, X.; Wang, Y.; Wu, D.; Zeng, Z.; Zeng, M.; Yi, H.; Luo, Z.; Yue, X.; Cheng, J.

    2014-11-01

    Muon tomography is an advanced technology to non-destructively detect high atomic number materials. It exploits the multiple Coulomb scattering information of muon to reconstruct the scattering density image of the traversed object. Because of the statistics of muon scattering, the measurement error of system and the data incompleteness, the reconstruction is always accompanied with a certain level of interference, which will influence the reconstructed spatial resolution. While statistical noises can be reduced by extending the measuring time, system parameters determine the ultimate spatial resolution that one system can reach. In this paper, an effective frequency-domain model is proposed to analyze the reconstructed spatial resolution of muon tomography. The proposed method modifies the resolution analysis in conventional computed tomography (CT) to fit the different imaging mechanism in muon scattering tomography. The measured scattering information is described in frequency domain, then a relationship between the measurements and the original image is proposed in Fourier domain, which is named as "Muon Central Slice Theorem". Furthermore, a preliminary analytical expression of the ultimate reconstructed spatial is derived, and the simulations are performed for validation. While the method is able to predict the ultimate spatial resolution of a given system, it can also be utilized for the optimization of system design and construction.

  7. Three-dimensional imaging of adherent cells using FIB/SEM and STEM.

    PubMed

    Villinger, Clarissa; Schauflinger, Martin; Gregorius, Heiko; Kranz, Christine; Höhn, Katharina; Nafeey, Soufi; Walther, Paul

    2014-01-01

    In this chapter we describe three different approaches for three-dimensional imaging of electron microscopic samples: serial sectioning transmission electron microscopy (TEM), scanning transmission electron microscopy (STEM) tomography, and focused ion beam/scanning electron microscopy (FIB/SEM) tomography. With these methods, relatively large volumes of resin-embedded biological structures can be analyzed at resolutions of a few nm within a reasonable expenditure of time. The traditional method is serial sectioning and imaging the same area in all sections. Another method is TEM tomography that involves tilting a section in the electron beam and then reconstruction of the volume by back projection of the images. When the scanning transmission (STEM) mode is used, thicker sections (up to 1 μm) can be analyzed. The third approach presented here is focused ion beam/scanning electron microscopy (FIB/SEM) tomography, in which a sample is repeatedly milled with a focused ion beam (FIB) and each newly produced block face is imaged with the scanning electron microscope (SEM). This process can be repeated ad libitum in arbitrary small increments allowing 3D analysis of relatively large volumes such as eukaryotic cells. We show that resolution of this approach is considerably improved when the secondary electron signal is used. However, the most important prerequisite for three-dimensional imaging is good specimen preparation. For all three imaging methods, cryo-fixed (high-pressure frozen) and freeze-substituted samples have been used.

  8. Microfluidic preparation and self diffusion PFG-NMR analysis of monodisperse water-in-oil-in-water double emulsions.

    PubMed

    Hughes, Eric; Maan, Abid Aslam; Acquistapace, Simone; Burbidge, Adam; Johns, Michael L; Gunes, Deniz Z; Clausen, Pascal; Syrbe, Axel; Hugo, Julien; Schroen, Karin; Miralles, Vincent; Atkins, Tim; Gray, Richard; Homewood, Philip; Zick, Klaus

    2013-01-01

    Monodisperse water-in-oil-in-water (WOW) double emulsions have been prepared using microfluidic glass devices designed and built primarily from off the shelf components. The systems were easy to assemble and use. They were capable of producing double emulsions with an outer droplet size from 100 to 40 μm. Depending on how the devices were operated, double emulsions containing either single or multiple water droplets could be produced. Pulsed-field gradient self-diffusion NMR experiments have been performed on the monodisperse water-in-oil-in-water double emulsions to obtain information on the inner water droplet diameter and the distribution of the water in the different phases of the double emulsion. This has been achieved by applying regularization methods to the self-diffusion data. Using these methods the stability of the double emulsions to osmotic pressure imbalance has been followed by observing the change in the size of the inner water droplets over time. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Different equation-of-motion coupled cluster methods with different reference functions: The formyl radical

    NASA Astrophysics Data System (ADS)

    Kuś, Tomasz; Bartlett, Rodney J.

    2008-09-01

    The doublet and quartet excited states of the formyl radical have been studied by the equation-of-motion (EOM) coupled cluster (CC) method. The Sz spin-conserving singles and doubles (EOM-EE-CCSD) and singles, doubles, and triples (EOM-EE-CCSDT) approaches, as well as the spin-flipped singles and doubles (EOM-SF-CCSD) method have been applied, subject to unrestricted Hartree-Fock (HF), restricted open-shell HF, and quasirestricted HF references. The structural parameters, vertical and adiabatic excitation energies, and harmonic vibrational frequencies have been calculated. The issue of the reference function choice for the spin-flipped (SF) method and its impact on the results has been discussed using the experimental data and theoretical results available. The results show that if the appropriate reference function is chosen so that target states differ from the reference by only single excitations, then EOM-EE-CCSD and EOM-SF-CCSD methods give a very good description of the excited states. For the states that have a non-negligible contribution of the doubly excited configurations one is able to use the SF method with such a reference function, that in most cases the performance of the EOM-SF-CCSD method is better than that of the EOM-EE-CCSD approach.

  10. [Deep learning and neuronal networks in ophthalmology : Applications in the field of optical coherence tomography].

    PubMed

    Treder, M; Eter, N

    2018-04-19

    Deep learning is increasingly becoming the focus of various imaging methods in medicine. Due to the large number of different imaging modalities, ophthalmology is particularly suitable for this field of application. This article gives a general overview on the topic of deep learning and its current applications in the field of optical coherence tomography. For the benefit of the reader it focuses on the clinical rather than the technical aspects.

  11. Teaching the Double Layer.

    ERIC Educational Resources Information Center

    Bockris, J. O'M.

    1983-01-01

    Suggests various methods for teaching the double layer in electrochemistry courses. Topics addressed include measuring change in absolute potential difference (PD) at interphase, conventional electrode potential scale, analyzing absolute PD, metal-metal and overlap electron PDs, accumulation of material at interphase, thermodynamics of electrified…

  12. X-ray computed tomography using curvelet sparse regularization.

    PubMed

    Wieczorek, Matthias; Frikel, Jürgen; Vogel, Jakob; Eggl, Elena; Kopp, Felix; Noël, Peter B; Pfeiffer, Franz; Demaret, Laurent; Lasser, Tobias

    2015-04-01

    Reconstruction of x-ray computed tomography (CT) data remains a mathematically challenging problem in medical imaging. Complementing the standard analytical reconstruction methods, sparse regularization is growing in importance, as it allows inclusion of prior knowledge. The paper presents a method for sparse regularization based on the curvelet frame for the application to iterative reconstruction in x-ray computed tomography. In this work, the authors present an iterative reconstruction approach based on the alternating direction method of multipliers using curvelet sparse regularization. Evaluation of the method is performed on a specifically crafted numerical phantom dataset to highlight the method's strengths. Additional evaluation is performed on two real datasets from commercial scanners with different noise characteristics, a clinical bone sample acquired in a micro-CT and a human abdomen scanned in a diagnostic CT. The results clearly illustrate that curvelet sparse regularization has characteristic strengths. In particular, it improves the restoration and resolution of highly directional, high contrast features with smooth contrast variations. The authors also compare this approach to the popular technique of total variation and to traditional filtered backprojection. The authors conclude that curvelet sparse regularization is able to improve reconstruction quality by reducing noise while preserving highly directional features.

  13. Double sampling to estimate density and population trends in birds

    USGS Publications Warehouse

    Bart, Jonathan; Earnst, Susan L.

    2002-01-01

    We present a method for estimating density of nesting birds based on double sampling. The approach involves surveying a large sample of plots using a rapid method such as uncorrected point counts, variable circular plot counts, or the recently suggested double-observer method. A subsample of those plots is also surveyed using intensive methods to determine actual density. The ratio of the mean count on those plots (using the rapid method) to the mean actual density (as determined by the intensive searches) is used to adjust results from the rapid method. The approach works well when results from the rapid method are highly correlated with actual density. We illustrate the method with three years of shorebird surveys from the tundra in northern Alaska. In the rapid method, surveyors covered ~10 ha h-1 and surveyed each plot a single time. The intensive surveys involved three thorough searches, required ~3 h ha-1, and took 20% of the study effort. Surveyors using the rapid method detected an average of 79% of birds present. That detection ratio was used to convert the index obtained in the rapid method into an essentially unbiased estimate of density. Trends estimated from several years of data would also be essentially unbiased. Other advantages of double sampling are that (1) the rapid method can be changed as new methods become available, (2) domains can be compared even if detection rates differ, (3) total population size can be estimated, and (4) valuable ancillary information (e.g. nest success) can be obtained on intensive plots with little additional effort. We suggest that double sampling be used to test the assumption that rapid methods, such as variable circular plot and double-observer methods, yield density estimates that are essentially unbiased. The feasibility of implementing double sampling in a range of habitats needs to be evaluated.

  14. Attenuation Tomography of Northern California and the Yellow Sea / Korean Peninsula from Coda-source Normalized and Direct Lg Amplitudes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, S R; Dreger, D S; Phillips, W S

    2008-07-16

    Inversions for regional attenuation (1/Q) of Lg are performed in two different regions. The path attenuation component of the Lg spectrum is isolated using the coda-source normalization method, which corrects the Lg spectral amplitude for the source using the stable, coda-derived source spectra. Tomographic images of Northern California agree well with one-dimensional (1-D) Lg Q estimated from five different methods. We note there is some tendency for tomographic smoothing to increase Q relative to targeted 1-D methods. For example in the San Francisco Bay Area, which contains high attenuation relative to the rest of it's region, Q is over-estimated bymore » {approx}30. Coda-source normalized attenuation tomography is also carried out for the Yellow Sea/Korean Peninsula (YSKP) where output parameters (site, source, and path terms) are compared with those from the amplitude tomography method of Phillips et al. (2005) as well as a new method that ties the source term to the MDAC formulation (Walter and Taylor, 2001). The source terms show similar scatter between coda-source corrected and MDAC source perturbation methods, whereas the amplitude method has the greatest correlation with estimated true source magnitude. The coda-source better represents the source spectra compared to the estimated magnitude and could be the cause of the scatter. The similarity in the source terms between the coda-source and MDAC-linked methods shows that the latter method may approximate the effect of the former, and therefore could be useful in regions without coda-derived sources. The site terms from the MDAC-linked method correlate slightly with global Vs30 measurements. While the coda-source and amplitude ratio methods do not correlate with Vs30 measurements, they do correlate with one another, which provides confidence that the two methods are consistent. The path Q{sup -1} values are very similar between the coda-source and amplitude ratio methods except for small differences in the Da-xin-anling Mountains, in the northern YSKP. However there is one large difference between the MDAC-linked method and the others in the region near stations TJN and INCN, which point to site-effect as the cause for the difference.« less

  15. Functional brain imaging and bioacoustics in the Bottlenose dolphins, Tursiops truncatus

    NASA Astrophysics Data System (ADS)

    Ridgway, Sam; Finneran, James; Carder, Donald; van Bonn, William; Smith, Cynthia; Houser, Dorian; Mattrey, Robert; Hoh, Carl

    2003-10-01

    The dolphin brain is the central processing computer for a complex and effective underwater echolocation and communication system. Until now, it has not been possible to study or diagnose disorders of the dolphin brain employing modern functional imaging methods like those used in human medicine. Our most recent studies employ established methods such as behavioral tasks, physiological observations, and computed tomography (CT) and, for the first time, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Trained dolphins slide out of their enclosure on to a mat and are transported by trainers and veterinarians to the laboratory for injection of a ligand. Following ligand injection, brief experiments include trained vocal responses to acoustic, visual, or tactile stimuli. We have used the ligand technetium (Tc-99m) biscisate (Neurolite) to image circulatory flow by SPECT. Fluro-deoxy-d-glucose (18-F-FDG) has been employed to image brain metabolism with PET. Veterinarians carefully monitored dolphins during and after the procedure. Through these methods, we have demonstrated that functional imaging can be employed safely and productively with dolphins to obtain valuable information on brain structure and function for medical and research purposes. Hemispheric differences and variations in flow and metabolism in different brain areas will be shown.

  16. Three-dimensional imaging of artificial fingerprint by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Larin, Kirill V.; Cheng, Yezeng

    2008-03-01

    Fingerprint recognition is one of the popular used methods of biometrics. However, due to the surface topography limitation, fingerprint recognition scanners are easily been spoofed, e.g. using artificial fingerprint dummies. Thus, biometric fingerprint identification devices need to be more accurate and secure to deal with different fraudulent methods including dummy fingerprints. Previously, we demonstrated that Optical Coherence Tomography (OCT) images revealed the presence of the artificial fingerprints (made from different household materials, such as cement and liquid silicone rubber) at all times, while the artificial fingerprints easily spoofed the commercial fingerprint reader. Also we demonstrated that an analysis of the autocorrelation of the OCT images could be used in automatic recognition systems. Here, we exploited the three-dimensional (3D) imaging of the artificial fingerprint by OCT to generate vivid 3D image for both the artificial fingerprint layer and the real fingerprint layer beneath. With the reconstructed 3D image, it could not only point out whether there exists an artificial material, which is intended to spoof the scanner, above the real finger, but also could provide the hacker's fingerprint. The results of these studies suggested that Optical Coherence Tomography could be a powerful real-time noninvasive method for accurate identification of artificial fingerprints real fingerprints as well.

  17. In Vitro Validation of an Artefact Suppression Algorithm in X-Ray Phase-Contrast Computed Tomography.

    PubMed

    Sunaguchi, Naoki; Yuasa, Tetsuya; Hirano, Shin-Ichi; Gupta, Rajiv; Ando, Masami

    2015-01-01

    X-ray phase-contrast tomography can significantly increase the contrast-resolution of conventional attenuation-contrast imaging, especially for soft-tissue structures that have very similar attenuation. Just as in attenuation-based tomography, phase contrast tomography requires a linear dependence of aggregate beam direction on the incremental direction alteration caused by individual voxels along the path of the X-ray beam. Dense objects such as calcifications in biological specimens violate this condition. There are extensive beam deflection artefacts in the vicinity of such structures because they result in large distortion of wave front due to the large difference of refractive index; for such large changes in beam direction, the transmittance of the silicon analyzer crystal saturates and is no longer linearly dependent on the angle of refraction. This paper describes a method by which these effects can be overcome and excellent soft-tissue contrast of phase tomography can be preserved in the vicinity of such artefact-producing structures.

  18. Solid-state nanopores of controlled geometry fabricated in a transmission electron microscope

    NASA Astrophysics Data System (ADS)

    Qian, Hui; Egerton, Ray F.

    2017-11-01

    Energy-filtered transmission electron microscopy and electron tomography were applied to in situ studies of the formation, shape, and diameter of nanopores formed in a silicon nitride membrane in a transmission electron microscope. The nanopore geometry was observed in three dimensions by electron tomography. Drilling conditions, such as probe current, beam convergence angle, and probe position, affect the formation rate and the geometry of the pores. With a beam convergence semi-angle of α = 22 mrad, a conical shaped nanopore is formed but at α = 45 mrad, double-cone (hourglass-shaped) nanopores were produced. Nanopores with an effective diameter between 10 nm and 1.8 nm were fabricated by controlling the drilling time.

  19. Incidence of retear with double-row versus single-row rotator cuff repair.

    PubMed

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi

    2014-11-01

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.

  20. [One-stage Operation through the Same Skin Incision for Synchronous Double Primary Breast and Lung Cancer;Report of a Case].

    PubMed

    Takahashi, Noriyuki; Kuga, Yoko; Uno, Satoko; Saito, Keita

    2018-02-01

    A 75-year-old woman noticed a small mass in the right side breast and consulted our hospital. The results of the detailed examination indicated the synchronous double primary right breast cancer and the same side lung cancer (rS5). One-stage operation from the same skin incision was scheduled. Volume rendering (VR) of computed tomography (CT)-scan was very useful in deciding the position and the length of the skin incision. The breast tumor resection and the right middle lobe resection were successfully performed through 6.5 cm skin incision.

  1. Photoreceptor Layer Thickness Changes During Dark Adaptation Observed With Ultrahigh-Resolution Optical Coherence Tomography

    PubMed Central

    Lu, Chen D.; Lee, ByungKun; Schottenhamml, Julia; Maier, Andreas; Pugh, Edward N.; Fujimoto, James G.

    2017-01-01

    Purpose To examine outer retinal band changes after flash stimulus and subsequent dark adaptation with ultrahigh-resolution optical coherence tomography (UHR-OCT). Methods Five dark-adapted left eyes of five normal subjects were imaged with 3-μm axial-resolution UHR-OCT during 30 minutes of dark adaptation following 96%, 54%, 23%, and 0% full-field and 54% half-field rhodopsin bleach. We identified the ellipsoid zone inner segment/outer segment (EZ[IS/OS]), cone interdigitation zone (CIZ), rod interdigitation zone (RIZ), retinal pigment epithelium (RPE), and Bruch's membrane (BM) axial positions and generated two-dimensional thickness maps of the EZ(IS/OS) to the four bands. The average thickness over an area of the thickness map was compared against that of the dark-adapted baselines. The time-dependent thickness changes (photoresponses) were statistically compared against 0% bleach. Dark adaptometry was performed with the same bleaching protocol. Results The EZ(IS/OS)-CIZ photoresponse was significantly different at 96% (P < 0.0001) and 54% (P = 0.006) bleach. At all three bleaching levels, the EZ(IS/OS)-RIZ, -RPE, and -BM responses were significantly different (P < 0.0001). The EZ(IS/OS)-CIZ and EZ(IS/OS)-RIZ time courses were similar to the recovery of rod- and cone-mediated sensitivity, respectively, measured with dark adaptometry. The maximal EZ(IS/OS)-CIZ and EZ(IS/OS)-RIZ response magnitudes doubled from 54% to 96% bleach. Both EZ(IS/OS)-RPE and EZ(IS/OS)-BM responses resembled dampened oscillations that were graded in amplitude and duration with bleaching intensity. Half-field photoresponses were localized to the stimulated retina. Conclusions With noninvasive, near-infrared UHR-OCT, we characterized three distinct, spatially localized photoresponses in the outer retinal bands. These photoresponses have potential value as physical correlates of photoreceptor function. PMID:28898357

  2. Effect of a Starting Model on the Solution of a Travel Time Seismic Tomography Problem

    NASA Astrophysics Data System (ADS)

    Yanovskaya, T. B.; Medvedev, S. V.; Gobarenko, V. S.

    2018-03-01

    In the problems of three-dimensional (3D) travel time seismic tomography where the data are travel times of diving waves and the starting model is a system of plane layers where the velocity is a function of depth alone, the solution turns out to strongly depend on the selection of the starting model. This is due to the fact that in the different starting models, the rays between the same points can intersect different layers, which makes the tomography problem fundamentally nonlinear. This effect is demonstrated by the model example. Based on the same example, it is shown how the starting model should be selected to ensure a solution close to the true velocity distribution. The starting model (the average dependence of the seismic velocity on depth) should be determined by the method of successive iterations at each step of which the horizontal velocity variations in the layers are determined by solving the two-dimensional tomography problem. An example illustrating the application of this technique to the P-wave travel time data in the region of the Black Sea basin is presented.

  3. Self-administered, inhaled methoxyflurane improves patient comfort during nasoduodenal intubation for computed tomography enteroclysis for suspected small bowel disease: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Moss, A; Parrish, F J; Naidoo, P; Upton, A; Prime, H; Leaney, B; Gibson, P R

    2011-02-01

    To determine the efficacy and safety of self-administered, inhaled analgesic, methoxyflurane, used to improve patient comfort during computed tomography enteroclysis (CTE). A randomized, double-blind, placebo-controlled trial was performed at two Australian hospitals (one tertiary referral public hospital and one private hospital). Patients were randomized to 3 ml methoxyflurane or saline (scented to maintain blindness) via hand-held inhaler. The main outcome measures were patient comfort during each stage of CTE and an overall rating as recorded by patients 1h post-procedure on a 10 cm visual analogue scale. Patient willingness to undergo repeat CTE, radiologist-rated ease of nasoduodenal intubation, and patient-rated ease of use of the inhaler were also assessed. Sixty patients (mean age 45 years; 41 women) were enrolled; 30 received methoxyflurane and were well matched to 30 receiving placebo. Procedural success was 98%. The mean dose of methoxyflurane consumed was 0.9 ml (SD 0.5). Patient comfort during nasoduodenal intubation was better with methoxyflurane {5.0 [95% confidence intervals (CI) 4.0-6.0]} than with placebo [2.7 (95% CI 1.8-3.7); p=0.002, t-test), but there were no significant differences for comfort levels at other times or overall. The inhaler was easy to use, was well tolerated, and there were no episodes of oxygen desaturation, aspiration, or anaphylaxis. Inhalational methoxyflurane safely improves patient comfort during nasoduodenal intubation, but does not improve overall procedure comfort. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Investigating the Potential of Computer Environments for the Teaching and Learning of Functions: A Double Analysis from Two Research Traditions

    ERIC Educational Resources Information Center

    Lagrange, Jean-Baptiste; Psycharis, Giorgos

    2014-01-01

    The general goal of this paper is to explore the potential of computer environments for the teaching and learning of functions. To address this, different theoretical frameworks and corresponding research traditions are available. In this study, we aim to network different frameworks by following a "double analysis" method to analyse two…

  5. Impact of Dynamic Specimen Shape Evolution on the Atom Probe Tomography Results of Doped Epitaxial Oxide Multilayers: Comparison of Experiment and Simulation

    DOE PAGES

    Madaan, Nitesh; Bao, Jie; Nandasiri, Manjula I.; ...

    2015-08-31

    The experimental atom probe tomography results from two different specimen orientations (top-down and side-ways) of a high oxygen ion conducting Samaria-doped-ceria/Scandia-stabilized-zirconia multilayer thin film solid oxide fuel cell electrolyte was correlated with level-set method based field evaporation simulations for the same specimen orientations. This experiment-theory correlation explains the dynamic specimen shape evolution and ion trajectory aberrations that can induce density artifacts in final reconstruction leading to inaccurate estimation of interfacial intermixing. This study highlights the need and importance of correlating experimental results with field evaporation simulations when using atom probe tomography for studying oxide heterostructure interfaces.

  6. Optical coherence tomography characteristics of different types of big bubbles seen in deep anterior lamellar keratoplasty by the big bubble technique

    PubMed Central

    AlTaan, S L; Termote, K; Elalfy, M S; Hogan, E; Werkmeister, R; Schmetterer, L; Holland, S; Dua, H S

    2016-01-01

    Purpose To define optical coherence tomography (OCT) characteristics of type-1, type-2, and mixed big bubbles (BB) seen in deep anterior lamellar keratoplasty. Methods Human sclero-corneal discs were obtained from UK (30) and Canada (16) eye banks. Air was injected into corneal stroma until a BB formed. UK samples were fixed in formalin before scanning with Fourier-domain (FD-OCT). One pair of each type of BB was scanned fresh. All BB obtained from Canada were scanned fresh with time-domain (TD-OCT). For each OCT machine used, type-1 BB from which Descemets membrane (DM) was partially peeled, were also scanned. The morphological characteristics of the scans were studied. Results FD-OCT of the posterior wall of type-1 (Dua's layer (DL) with DM) and type-2 BB (DM alone) both revealed a double-contour hyper-reflective curvilinear image with a hypo-reflective zone in between. The anterior line of type-2 BB was thinner than that seen with type-1 BB. In mixed BB, FD-OCT showed two separate curvilinear images. The anterior image was a single hyper-reflective line (DL), whereas the posterior image, representing the posterior wall of type-2 BB (DM) was made of two hyper-reflective lines with a dark space in between. TD-OCT images were similar with less defined component lines, but the entire extent of the BB could be visualised. Conclusion On OCT examination the DM and DL present distinct features, which can help identify type-1, type-2, and mixed BB. These characteristics will help corneal surgeons interpret intraoperative OCT during lamellar corneal surgery. PMID:27472215

  7. Joint inversion for Vp, Vs, and Vp/Vs at SAFOD, Parkfield, California

    USGS Publications Warehouse

    Zhang, H.; Thurber, C.; Bedrosian, P.

    2009-01-01

    We refined the three-dimensional (3-D) Vp, Vs and Vp/Vs models around the San Andreas Fault Observatory at Depth (SAFOD) site using a new double-difference (DD) seismic tomography code (tomoDDPS) that simultaneously solves for earthquake locations and all three velocity models using both absolute and differential P, S, and S-P times. This new method is able to provide a more robust Vp/Vs model than that from the original DD tomography code (tomoDD), obtained simply by dividing Vp by Vs. For the new inversion, waveform cross-correlation times for earthquakes from 2001 to 2002 were also used, in addition to arrival times from earthquakes and explosions in the region. The Vp values extracted from the model along the SAFOD trajectory match well with the borehole log data, providing in situ confirmation of our results. Similar to previous tomographic studies, the 3-D structure around Parkfield is dominated by the velocity contrast across the San Andreas Fault (SAF). In both the Vp and Vs models, there is a clear low-velocity zone as deep as 7 km along the SAF trace, compatible with the findings from fault zone guided waves. There is a high Vp/Vs anomaly zone on the southwest side of the SAF trace that is about 1-2 km wide and extends as deep as 4 km, which is interpreted to be due to fluids and fractures in the package of sedimentary rocks abutting the Salinian basement rock to the southwest. The relocated earthquakes align beneath the northeast edge of this high Vp/Vs zone. We carried out a 2-D correlation analysis for an existing resistivity model and the corresponding profiles through our model, yielding a classification that distinguishes several major lithologies. ?? 2009 by the American Geophysical Union.

  8. A novel technique for finding gas bubbles in the nuclear waste containers using Muon Scattering Tomography

    NASA Astrophysics Data System (ADS)

    Dobrowolska, M.; Velthuis, J.; Frazão, L.; Kikoła, D.

    2018-05-01

    Nuclear waste is deposited for many years in the concrete or bitumen-filled containers. With time hydrogen gas is produced, which can accumulate in bubbles. These pockets of gas may result in bitumen overflowing out of the waste containers and could result in spread of radioactivity. Muon Scattering Tomography is a non-invasive scanning method developed to examine the unknown content of nuclear waste drums. Here we present a method which allows us to successfully detect bubbles larger than 2 litres and determine their size with a relative uncertainty resolution of 1.55 ± 0.77%. Furthermore, the method allows to make a distinction between a conglomeration of bubbles and a few smaller gas volumes in different locations.

  9. Near-surface shear-wave velocity measurements in unlithified sediment

    USGS Publications Warehouse

    Richards, B.T.; Steeples, D.; Miller, R.; Ivanov, J.; Peterie, S.; Sloan, S.D.; McKenna, J.R.

    2011-01-01

    S-wave velocity can be directly correlated to material stiffness and lithology making it a valuable physical property that has found uses in construction, engineering, and environmental projects. This study compares different methods for measuring S-wave velocities, investigating and identifying the differences among the methods' results, and prioritizing the different methods for optimal S-wave use at the U. S. Army's Yuma Proving Grounds YPG. Multichannel Analysis of Surface Waves MASW and S-wave tomography were used to generate S-wave velocity profiles. Each method has advantages and disadvantages. A strong signal-to-noise ratio at the study site gives the MASW method promising resolution. S-wave first arrivals are picked on impulsive sledgehammer data which were then used for the tomography process. Three-component downhole seismic data were collected in-line with a locking geophone, providing ground truth to compare the data and to draw conclusions about the validity of each data set. Results from these S-wave measurement techniques are compared with borehole seismic data and with lithology data from continuous samples to help ascertain the accuracy, and therefore applicability, of each method. This study helps to select the best methods for obtaining S-wave velocities for media much like those found in unconsolidated sediments at YPG. ?? 2011 Society of Exploration Geophysicists.

  10. MDCT diagnosis of post-traumatic hepatic arterio-portal fistulas.

    PubMed

    Nguyen, Cuong T; Nguyen, Coung; Saksobhavivat, Nitima; Saksobahavivat, Nitima; Shanmuganathan, Kathirkamanathan; Steenburg, Scott D; Steenburg, Scott; Moeslein, Fred M; Moeslein, Fred; Mirvis, Stuart E; Chiu, William

    2013-06-01

    The purpose of this study is to evaluate the performance of multidetector computed tomography (MDCT) in diagnosing arterioportal fistulas (APF) in high-grade liver injury. A retrospective analysis of catheter-based hepatic angiograms performed for major penetrating and blunt liver injuries identified 11 patients with APFs. Using the trauma registry, two additional demographically matched groups with and without liver injury were formed. A randomized qualitative consensus review of 33 MDCTs was performed by three trauma radiologists for the following MDCT findings of APF: transient hepatic parenchymal attenuation differences (THPAD), early increased attenuation of a peripheral or central portal vein compared with the main portal vein, and the "double-barrel" or "rail tract" signs. THPAD was the most sensitive finding and also had a high specificity for diagnosing APF. Both the early increased attenuation of a peripheral or central portal vein compared with the main portal vein and the double-barrel or rail tract signs had a100% specificity and a sensitivity of 64% and 36%, respectively. Measurement of differences in attenuation values between the APF and the contralateral central portal vein was most sensitive and specific in diagnosing APF. Traumatic APF of the liver can be optimally diagnosed with arterial phase imaging of solid organ using MDCT.

  11. High-resolution coded-aperture design for compressive X-ray tomography using low resolution detectors

    NASA Astrophysics Data System (ADS)

    Mojica, Edson; Pertuz, Said; Arguello, Henry

    2017-12-01

    One of the main challenges in Computed Tomography (CT) is obtaining accurate reconstructions of the imaged object while keeping a low radiation dose in the acquisition process. In order to solve this problem, several researchers have proposed the use of compressed sensing for reducing the amount of measurements required to perform CT. This paper tackles the problem of designing high-resolution coded apertures for compressed sensing computed tomography. In contrast to previous approaches, we aim at designing apertures to be used with low-resolution detectors in order to achieve super-resolution. The proposed method iteratively improves random coded apertures using a gradient descent algorithm subject to constraints in the coherence and homogeneity of the compressive sensing matrix induced by the coded aperture. Experiments with different test sets show consistent results for different transmittances, number of shots and super-resolution factors.

  12. Forward problem studies of electrical resistance tomography system on concrete materials

    NASA Astrophysics Data System (ADS)

    Ang, Vernoon; Rahiman, M. H. F.; Rahim, R. A.; Aw, S. R.; Wahab, Y. A.; Thomas W. K., T.; Siow, L. T.

    2017-03-01

    Electrical resistance tomography (ERT) is well known as non-invasive imaging technique, inexpensive, radiation free, visualization measurements of the multiphase flows and frequently applied in geophysical, medical and Industrial Process Tomography (IPT) applications. Application of ERT in concrete is a new exploration field, which can be used in monitoring and detecting the health and condition of concrete without destroying it. In this paper, ERT model under the condition of concrete is studied in which the sensitivity field model is produced and simulated by using COMSOL software. The affects brought by different current injection values with different concrete conductivity are studied in detail. This study able to provide the important direction for the further study of inverse problem in ERT system. Besides, the results of this technique hopefully can open a new exploration in inspection method of concrete structures in order to maintain the health of the concrete structure for civilian safety.

  13. The role of positron emission tomography and positron emission tomography/computed tomography in thyroid tumours: an overview.

    PubMed

    Treglia, Giorgio; Muoio, Barbara; Giovanella, Luca; Salvatori, Massimo

    2013-05-01

    Positron emission tomography (PET) and PET/computed tomography (PET/CT) with different tracers have been increasingly used in patients with thyroid tumours. The aim of this article is to perform an overview based on literature data about the usefulness of PET imaging in this setting. The role of Fluorine-18-Fluorodeoxyglucose (FDG) PET and PET/CT in differentiated thyroid carcinoma (DTC) is well established, particularly in patients presenting with elevated serum thyroglobulin levels and negative radioiodine whole-body scan. Iodine-124 PET and PET/CT may serve a role in staging DTC and obtaining lesional dosimetry for a better and more rationale planning of treatment with Iodine-131. FDG-PET and PET/CT are useful in the post-thyroidectomy staging of high-risk patients with less differentiated histological subtypes. PET and PET/CT with different tracers seem to be useful methods in localizing the source of elevated calcitonin levels in patients with recurrent medullary thyroid carcinoma. Incorporation of FDG-PET or PET/CT into the initial workup of patients with indeterminate thyroid nodules at fine needle aspiration biopsy deserves further investigation. FDG-PET report should suggest further evaluation when focal thyroid incidentalomas are described because these findings are associated with a significant risk of cancer.

  14. Volumetric Evaluation of Different Obturation Techniques in Primary Teeth Using Spiral Computed Tomography.

    PubMed

    Nagaveni, N B; Yadav, Sneha; Poornima, P; Reddy, Vv Subba; Roshan, N M

    Various obturation techniques have been evaluated for better filling of the root canals in primary teeth using different methods. Spiral Computed Tomography (SCT) is a new revolution in the pediatric endodontics for assessment of quality of the obturation from 3 dimensions. To evaluate the efficiency of 5 different obturation methods in delivering the filling material into the canals of primary teeth using Spiral Computed Tomography scan. A total of 50 canals of primary teeth were prepared, divided into 5 groups with 10 canals in each group and obturated with Zinc Oxide Eugenol cement using 5 different obturation techniques such as Local anesthetic syringe, Tuberculin syringe, Endodontic plugger, hand held Lentulo-spiral, and Lentulo-spiral mounted on slow speed hand piece. The pre and post obturation volume and finally the Percentage of Obturated Volume (POV) were calculated using SCT scan for each group. The data obtained was statistically analyzed using One-way Analysis of Variance (ANOVA) and Tukey's post-hoc test. Lentulo-spiral hand held showed highest POV value followed by Lentulospiral mounted to hand piece, Tuberculin syringe and Endodontic plugger; whereas Anesthetic syringe had least POV (P < 0.05). Lentulo-spiral hand held is the best obturating technique among the 5 groups evaluated as the canals of this group showed maximum percentage of filled material. However, a further study with large sample size is highly essential.

  15. Speckle contrast optical tomography: A new method for deep tissue three-dimensional tomography of blood flow

    PubMed Central

    Varma, Hari M.; Valdes, Claudia P.; Kristoffersen, Anna K.; Culver, Joseph P.; Durduran, Turgut

    2014-01-01

    A novel tomographic method based on the laser speckle contrast, speckle contrast optical tomography (SCOT) is introduced that allows us to reconstruct three dimensional distribution of blood flow in deep tissues. This method is analogous to the diffuse optical tomography (DOT) but for deep tissue blood flow. We develop a reconstruction algorithm based on first Born approximation to generate three dimensional distribution of flow using the experimental data obtained from tissue simulating phantoms. PMID:24761306

  16. [Influence of different designs and porcelain/glaze firing on the marginal and internal fit of implant-supported zirconia crowns].

    PubMed

    Cuiling, Liu; Xu, Gao; Yuping, Qi; Liyuan, Yang

    2016-02-01

    This study investigated the influence of different designs and porcelain/glaze firing on the marginal and internal fit of three kinds of computer aided design/computer aided manufacturing (CAD/CAM) zirconia ceramic implant-supported crowns. Three groups of zirconia ceramic implant-supported crowns with different designs were produced from copings by using a Cercon CAD/CAM system (n = 8). The first two groups comprised double-layer crowns (zirconia coping + veneer) with regular (Group A) and full circumferential zirconia-collar marginal designs (Group B). The third group was composed of anatomic single-layer zirconia crowns without cores (Group C). Initially, the marginal and internal gaps of the copings and crowns were individually replicated by light-body silicon and then measured by micro-computed tomography scanning before and after porcelain/glaze firing. Five measurements were employed: vertical marginal gap (MG); horizontal marginal discrepancy (HMD); chamfer area (CA); axial wall (AW); and axial-occlusal transition area (AOT). Statistical analyses were performed by SPSS 17.0. HMD measurements in Group A were statistically higher than those in Groups B and C (P < 0.05), regardless of whether the values were obtained before or after porcelain/glaze firing. By contrast, the HIMD measurements in Groups B and C showed no significant difference (P > 0.05). Moreover, no differences were noted in MG, CA, AW, and AOT among the three groups (P > 0.05). All the measurements in the three groups showed no significant change after porcelain/glaze firing (P > 0.05), except for MG in Group A, which significantly decreased (P < 0.05). The marginal fits of the double-layer crowns with full circumferential zirconia-collar and the anatomic single-layer zirconia crowns were superior to that of the double-layer crowns with regular margins. The MG of the crowns with regular margins was obviously influenced by porcelain firing.

  17. Imaging lithosphere structures using long period surface waves from ambient noise: a case study in western USA

    NASA Astrophysics Data System (ADS)

    Yang, Y.

    2013-12-01

    Since the emerging of ambient noise tomography in 2005, it has become a well-established method and been applied all over the world to imaging crustal and uppermost mantle structures because of its exclusive capability to extract short period surface waves. Most studies of ambient noise tomography performed so far use surface waves at periods shorter than 40/50 sec. There are a few studies of long period surface wave tomography from ambient noise (longer than 50 sec) in continental and global scales. To our knowledge, almost no tomography studies have been performed using long period surface waves (~50-200 sec) from ambient noise in regional scales with an aperture of several hundred kilometres. In this study, we demonstrate the capability of using long period surface waves from ambient noise in regional surface wave tomography by showing a case study of western USA using the USArray Transportable component (TA). We select about 150 TA stations located in a region including northern California, northern Nevada and Oregon as the 'base' stations and about 200 stations from Global Seismographic Network (GSN) and The International Federation of Digital Seismograph Networks (FDSN) as the 'remote' stations. We perform monthly cross-correlations of continuous ambient noise data recorded in 2006-2008 between the 'base' stations and the 'remote' stations and then use a stacking method based on instantaneous phase coherence to stack the monthly cross-correlations to obtain the final cross-correlations. The results show that high signal-to-noise ratio long period Raleigh waves are obtained between the 'base' stations and 'remote' stations located several thousand or even more than ten thousand kilometres away from the 'base' stations. By treating each of the 'remote' station as a 'virtual' teleseismic earthquake and measuring surface wave phases at the 'base' stations, we generate phase velocity maps at 50-200 sec periods in the regions covered by the 'base' stations using an array-based two-plane-wave tomography method. To evaluate the reliability of the resulting phase velocity maps, we compare them with published phase velocity maps using the same tomography method but based on teleseismic data. The comparison shows that long period surface wave phase velocity maps based 'virtual' events from ambient noise and those based on natural earthquakes are very similar with differences within the range of uncertainties. The similarity of phase velocity maps justifies the application of long period surface waves from ambient noise in regional lithosphere imaging. The successful extraction of long period surface waves between station pairs with distances as long as several thousand or ten thousand kilometres can link seismic arrays located in different continents, such as CEArray in China and USArray in USA. With the rapid developments of large scale seismic arrays in different continents, those inter-continental surface waves from ambient noise can be incorporated in both regional- and global-scale surface wave tomography to significantly increase the path coverage in both lateral and azimuthal senses, which is essential to improving imaging of high resolution heterogeneities and azimuthal anisotropy, especially at regions with gaps of azimuthal distributions of earthquakes.

  18. How bright planets became dim stars: planetary speculations in John Herschel's double star astronomy

    NASA Astrophysics Data System (ADS)

    Case, S.

    2014-03-01

    Previous research on the origins of double star astronomy in the early nineteenth century emphasized the role mathematical methods and instrumentation played in motivating early observations of these objects. The work of the British astronomer John Herschel, however, shows that questions regarding the physical nature of double stars were also important. In particular, an analysis of John Herschel's early work on double stars illustrates the way in which speculations regarding these objects were shaped by assumptions of the properties of stars themselves. For Herschel, a major consideration in double star astronomy was distinguishing between types of double stars. Optical doubles were useful in determining parallax while binary doubles were not. In practice, classification of a specific double star pair into one of these categories was based on the assumption that stars were of approximately the same luminosity and thus differences in relative brightness between stars were caused by difference in distances. Such assumptions, though ultimately abandoned, would lead Herschel in the 1830s to advance the possibility that the dim companion stars in certain double star pairs were not stars at all but in fact planets.

  19. How bright planets became dim stars: planetary speculations in John Herschel's double star astronomy.

    PubMed

    Case, Stephen

    2014-03-01

    Previous research on the origins of double star astronomy in the early nineteenth century emphasized the role mathematical methods and instrumentation played in motivating early observations of these objects. The work of the British astronomer John Herschel, however, shows that questions regarding the physical nature of double stars were also important. In particular, an analysis of John Herschel's early work on double stars illustrates the way in which speculations regarding these objects were shaped by assumptions of the properties of stars themselves. For Herschel, a major consideration in double star astronomy was distinguishing between types of double stars. Optical doubles were useful in determining parallax while binary doubles were not. In practice, classification of a specific double star pair into one of these categories was based on the assumption that stars were of approximately the same luminosity and thus differences in relative brightness between stars were caused by difference in distances. Such assumptions, though ultimately abandoned, would lead Herschel in the 1830s to advance the possibility that the dim companion stars in certain double star pairs were not stars at all but in fact planets. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. High-resolution computed tomography of the middle ear and mastoid. Part III. Surgically altered anatomy and pathology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swartz, J.D.; Goodman, R.S.; Russell, K.B.

    1983-08-01

    High-resolution computed tomography (CT) provides an excellent method for examination of the surgically altered middle ear and mastoid. Closed-cavity and open-cavity types of mastoidectomy are illustrated. Recurrent cholesteatoma in the mastoid bowl is easily diagnosed. Different types of tympanoplasty are discussed and illustrated, as are tympanostomy tubes and various ossicular reconstructive procedures. Baseline high-resolution CT of the postoperative middle ear and mastoid is recommended at approximately 3 months following the surgical procedure.

  1. Collimator-free photon tomography

    DOEpatents

    Dilmanian, F. Avraham; Barbour, Randall L.

    1998-10-06

    A method of uncollimated single photon emission computed tomography includes administering a radioisotope to a patient for producing gamma ray photons from a source inside the patient. Emissivity of the photons is measured externally of the patient with an uncollimated gamma camera at a plurality of measurement positions surrounding the patient for obtaining corresponding energy spectrums thereat. Photon emissivity at the plurality of measurement positions is predicted using an initial prediction of an image of the source. The predicted and measured photon emissivities are compared to obtain differences therebetween. Prediction and comparison is iterated by updating the image prediction until the differences are below a threshold for obtaining a final prediction of the source image.

  2. Timelapse ultrasonic tomography for measuring damage localization in geomechanics laboratory tests.

    PubMed

    Tudisco, Erika; Roux, Philippe; Hall, Stephen A; Viggiani, Giulia M B; Viggiani, Gioacchino

    2015-03-01

    Variation of mechanical properties in materials can be detected non-destructively using ultrasonic measurements. In particular, changes in elastic wave velocity can occur due to damage, i.e., micro-cracking and particles debonding. Here the challenge of characterizing damage in geomaterials, i.e., rocks and soils, is addressed. Geomaterials are naturally heterogeneous media in which the deformation can localize, so that few measurements of acoustic velocity across the sample are not sufficient to capture the heterogeneities. Therefore, an ultrasonic tomography procedure has been implemented to map the spatial and temporal variations in propagation velocity, which provides information on the damage process. Moreover, double beamforming has been successfully applied to identify and isolate multiple arrivals that are caused by strong heterogeneities (natural or induced by the deformation process). The applicability of the developed experimental technique to laboratory geomechanics testing is illustrated using data acquired on a sample of natural rock before and after being deformed under triaxial compression. The approach is then validated and extended to time-lapse monitoring using data acquired during plane strain compression of a sample including a well defined layer with different mechanical properties than the matrix.

  3. Analytical and experimental investigation on transmission loss of clamped double panels: implication of boundary effects.

    PubMed

    Xin, F X; Lu, T J

    2009-03-01

    The air-borne sound insulation performance of a rectangular double-panel partition clamp mounted on an infinite acoustic rigid baffle is investigated both analytically and experimentally and compared with that of a simply supported one. With the clamped (or simply supported) boundary accounted for by using the method of modal function, a double series solution for the sound transmission loss (STL) of the structure is obtained by employing the weighted residual (Galerkin) method. Experimental measurements with Al double-panel partitions having air cavity are subsequently carried out to validate the theoretical model for both types of the boundary condition, and good overall agreement is achieved. A consistency check of the two different models (based separately on clamped modal function and simply supported modal function) is performed by extending the panel dimensions to infinite where no boundaries exist. The significant discrepancies between the two different boundary conditions are demonstrated in terms of the STL versus frequency plots as well as the panel deflection mode shapes.

  4. Nano-Computed Tomography: Technique and Applications.

    PubMed

    Kampschulte, M; Langheinirch, A C; Sender, J; Litzlbauer, H D; Althöhn, U; Schwab, J D; Alejandre-Lafont, E; Martels, G; Krombach, G A

    2016-02-01

    Nano-computed tomography (nano-CT) is an emerging, high-resolution cross-sectional imaging technique and represents a technical advancement of the established micro-CT technology. Based on the application of a transmission target X-ray tube, the focal spot size can be decreased down to diameters less than 400 nanometers (nm). Together with specific detectors and examination protocols, a superior spatial resolution up to 400 nm (10 % MTF) can be achieved, thereby exceeding the resolution capacity of typical micro-CT systems. The technical concept of nano-CT imaging as well as the basics of specimen preparation are demonstrated exemplarily. Characteristics of atherosclerotic plaques (intraplaque hemorrhage and calcifications) in a murine model of atherosclerosis (ApoE (-/-)/LDLR(-/-) double knockout mouse) are demonstrated in the context of superior spatial resolution in comparison to micro-CT. Furthermore, this article presents the application of nano-CT for imaging cerebral microcirculation (murine), lung structures (porcine), and trabecular microstructure (ovine) in contrast to micro-CT imaging. This review shows the potential of nano-CT as a radiological method in biomedical basic research and discusses the application of experimental, high resolution CT techniques in consideration of other high resolution cross-sectional imaging techniques. Nano-computed tomography is a high resolution CT-technology for 3D imaging at sub-micrometer resolution. The technical concept bases on a further development of the established ex-vivo-micro-CT technology. By improvement of the spatial resolution, structures at a cellular level become visible (e.g. osteocyte lacunae). © Georg Thieme Verlag KG Stuttgart · New York.

  5. Monitoring of interaction of low-frequency electric field with biological tissues upon optical clearing with optical coherence tomography.

    PubMed

    Peña, Adrián F; Doronin, Alexander; Tuchin, Valery V; Meglinski, Igor

    2014-08-01

    The influence of a low-frequency electric field applied to soft biological tissues ex vivo at normal conditions and upon the topical application of optical clearing agents has been studied by optical coherence tomography (OCT). The electro-kinetic response of tissues has been observed and quantitatively evaluated by the double correlation OCT approach, utilizing consistent application of an adaptive Wiener filtering and Fourier domain correlation algorithm. The results show that fluctuations, induced by the electric field within the biological tissues are exponentially increased in time. We demonstrate that in comparison to impedance measurements and the mapping of the temperature profile at the surface of the tissue samples, the double correlation OCT approach is much more sensitive to the changes associated with the tissues' electro-kinetic response. We also found that topical application of the optical clearing agent reduces the tissues' electro-kinetic response and is cooling the tissue, thus reducing the temperature induced by the electric current by a few degrees. We anticipate that dcOCT approach can find a new application in bioelectrical impedance analysis and monitoring of the electric properties of biological tissues, including the resistivity of high water content tissues and its variations.

  6. Detection of cerebral amyloid angiopathy by 3-T magnetic resonance imaging and amyloid positron emission tomography in a patient with subcortical ischaemic vascular dementia.

    PubMed

    Kida, Hirotaka; Satoh, Masayuki; Ii, Yuichiro; Fukuyama, Hidenao; Maeda, Masayuki; Tomimoto, Hidekazu

    2017-01-01

    The patient was an 81-year-old man who had been treated for hypertension for several decades. In 2012, he developed gait disturbance and mild amnesia. One year later, his gait disturbance worsened, and he developed urinary incontinence. Conventional brain magnetic resonance imaging using T 2 -weighted images and fluid-attenuated inversion recovery showed multiple lacunar infarctions. These findings fulfilled the diagnostic criteria for subcortical ischaemic vascular dementia. However, susceptibility weighted imaging showed multiple lobar microbleeds in the bilateral occipitoparietal lobes, and double inversion recovery and 3-D fluid-attenuated inversion recovery images on 3-T magnetic resonance imaging revealed cortical microinfarctions in the left parietal-temporo-occipito region. Pittsburgh compound B-positron emission tomography revealed diffuse uptake in the cerebral cortex. Therefore, we diagnosed the patient with subcortical ischaemic vascular dementia associated with Alzheimer's disease. The use of the double inversion recovery and susceptibility weighted imaging on 3-T magnetic resonance imaging may be a supplemental strategy for diagnosing cerebral amyloid angiopathy, which is closely associated with Alzheimer's disease. © 2016 The Authors. Psychogeriatrics © 2016 Japanese Psychogeriatric Society.

  7. Combined spectral-domain optical coherence tomography and hyperspectral imaging applied for tissue analysis: Preliminary results

    NASA Astrophysics Data System (ADS)

    Dontu, S.; Miclos, S.; Savastru, D.; Tautan, M.

    2017-09-01

    In recent years many optoelectronic techniques have been developed for improvement and the development of devices for tissue analysis. Spectral-Domain Optical Coherence Tomography (SD-OCT) is a new medical interferometric imaging modality that provides depth resolved tissue structure information with resolution in the μm range. However, SD-OCT has its own limitations and cannot offer the biochemical information of the tissue. These data can be obtained with hyperspectral imaging, a non-invasive, sensitive and real time technique. In the present study we have combined Spectral-Domain Optical Coherence Tomography (SD-OCT) with Hyperspectral imaging (HSI) for tissue analysis. The Spectral-Domain Optical Coherence Tomography (SD-OCT) and Hyperspectral imaging (HSI) are two methods that have demonstrated significant potential in this context. Preliminary results using different tissue have highlighted the capabilities of this technique of combinations.

  8. A Comparison of Vertical Stiffness Values Calculated from Different Measures of Center of Mass Displacement in Single-Leg Hopping.

    PubMed

    Mudie, Kurt L; Gupta, Amitabh; Green, Simon; Hobara, Hiroaki; Clothier, Peter J

    2017-02-01

    This study assessed the agreement between K vert calculated from 4 different methods of estimating vertical displacement of the center of mass (COM) during single-leg hopping. Healthy participants (N = 38) completed a 10-s single-leg hopping effort on a force plate, with 3D motion of the lower limb, pelvis, and trunk captured. Derived variables were calculated for a total of 753 hop cycles using 4 methods, including: double integration of the vertical ground reaction force, law of falling bodies, a marker cluster on the sacrum, and a segmental analysis method. Bland-Altman plots demonstrated that K vert calculated using segmental analysis and double integration methods have a relatively small bias (0.93 kN⋅m -1 ) and 95% limits of agreement (-1.89 to 3.75 kN⋅m -1 ). In contrast, a greater bias was revealed between sacral marker cluster and segmental analysis (-2.32 kN⋅m -1 ), sacral marker cluster and double integration (-3.25 kN⋅m -1 ), and the law of falling bodies compared with all methods (17.26-20.52 kN⋅m -1 ). These findings suggest the segmental analysis and double integration methods can be used interchangeably for the calculation of K vert during single-leg hopping. The authors propose the segmental analysis method to be considered the gold standard for the calculation of K vert during single-leg, on-the-spot hopping.

  9. Y2O3:Yb,Er@mSiO2-CuxS double-shelled hollow spheres for enhanced chemo-/photothermal anti-cancer therapy and dual-modal imaging

    NASA Astrophysics Data System (ADS)

    Yang, Dan; Yang, Guixin; Wang, Xingmei; Lv, Ruichan; Gai, Shili; He, Fei; Gulzar, Arif; Yang, Piaoping

    2015-07-01

    Multifunctional composites have gained significant interest due to their unique properties which show potential in biological imaging and therapeutics. However, the design of an efficient combination of multiple diagnostic and therapeutic modes is still a challenge. In this contribution, Y2O3:Yb,Er@mSiO2 double-shelled hollow spheres (DSHSs) with up-conversion fluorescence have been successfully prepared through a facile integrated sacrifice template method, followed by a calcination process. It is found that the double-shelled structure with large specific surface area and uniform shape is composed of an inner shell of luminescent Y2O3:Yb,Er and an outer mesoporous silica shell. Ultra small CuxS nanoparticles (about 2.5 nm) served as photothermal agents, and a chemotherapeutic agent (doxorubicin, DOX) was then attached onto the surface of mesoporous silica, forming a DOX-DSHS-CuxS composite. The composite exhibits high anti-cancer efficacy due to the synergistic photothermal therapy (PTT) induced by the attached CuxS nanoparticles and the enhanced chemotherapy promoted by the heat from the CuxS-based PTT when irradiated by 980 nm near-infrared (NIR) light. Moreover, the composite shows excellent in vitro and in vivo X-ray computed tomography (CT) and up-conversion fluorescence (UCL) imaging properties owing to the doped rare earth ions, thus making it possible to achieve the target of imaging-guided synergistic therapy.Multifunctional composites have gained significant interest due to their unique properties which show potential in biological imaging and therapeutics. However, the design of an efficient combination of multiple diagnostic and therapeutic modes is still a challenge. In this contribution, Y2O3:Yb,Er@mSiO2 double-shelled hollow spheres (DSHSs) with up-conversion fluorescence have been successfully prepared through a facile integrated sacrifice template method, followed by a calcination process. It is found that the double-shelled structure with large specific surface area and uniform shape is composed of an inner shell of luminescent Y2O3:Yb,Er and an outer mesoporous silica shell. Ultra small CuxS nanoparticles (about 2.5 nm) served as photothermal agents, and a chemotherapeutic agent (doxorubicin, DOX) was then attached onto the surface of mesoporous silica, forming a DOX-DSHS-CuxS composite. The composite exhibits high anti-cancer efficacy due to the synergistic photothermal therapy (PTT) induced by the attached CuxS nanoparticles and the enhanced chemotherapy promoted by the heat from the CuxS-based PTT when irradiated by 980 nm near-infrared (NIR) light. Moreover, the composite shows excellent in vitro and in vivo X-ray computed tomography (CT) and up-conversion fluorescence (UCL) imaging properties owing to the doped rare earth ions, thus making it possible to achieve the target of imaging-guided synergistic therapy. Electronic supplementary information (ESI) available: XRD patterns, zeta potential and FT-IR spectra of the samples obtained in different steps. N2 adsorption/desorption isotherm and the pore size distribution of Y2O3:Yb,Er@mSiO2-CuxS. Confocal images of HeLa cancer cells dyed with calcein AM and propidium iodide co-stained cells after treatment of Y2O3:Yb,Er@mSiO2-CuxS without or with 980 nm laser irradiation. CLSM images of HeLa cells incubated with DOX-Y2O3:Yb,Er@mSiO2-NH2-FA-CuxS-PEG and DOX-Y2O3:Yb,Er@mSiO2-NH2-CuxS-PEG for different times. The digital photographs of the H22 tumor-bearing Balb/c mice injected in situ with DOX-Y2O3:Yb,Er@mSiO2-NH2-FA-CuxS-PEG and DOX-Y2O3:Yb,Er@mSiO2-NH2-CuxS-PEG and the corresponding tumor sizes. See DOI: 10.1039/c5nr02269j

  10. Camera calibration for multidirectional flame chemiluminescence tomography

    NASA Astrophysics Data System (ADS)

    Wang, Jia; Zhang, Weiguang; Zhang, Yuhong; Yu, Xun

    2017-04-01

    Flame chemiluminescence tomography (FCT), which combines computerized tomography theory and multidirectional chemiluminescence emission measurements, can realize instantaneous three-dimensional (3-D) diagnostics for flames with high spatial and temporal resolutions. One critical step of FCT is to record the projections by multiple cameras from different view angles. For high accuracy reconstructions, it requires that extrinsic parameters (the positions and orientations) and intrinsic parameters (especially the image distances) of cameras be accurately calibrated first. Taking the focus effect of the camera into account, a modified camera calibration method was presented for FCT, and a 3-D calibration pattern was designed to solve the parameters. The precision of the method was evaluated by reprojections of feature points to cameras with the calibration results. The maximum root mean square error of the feature points' position is 1.42 pixels and 0.0064 mm for the image distance. An FCT system with 12 cameras was calibrated by the proposed method and the 3-D CH* intensity of a propane flame was measured. The results showed that the FCT system provides reasonable reconstruction accuracy using the camera's calibration results.

  11. Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity.

    PubMed

    Hohlweg-Majert, B; Metzger, M C; Kummer, T; Schulze, D

    2011-07-01

    Modified quantitative computed tomography is a method used to predict bone quality and quantify the bone mass of the jaw. The aim of this study was to determine whether bone quantity or quality was detected by cone beam computed tomography (CBCT) combined with image analysis. MATERIALS AND PROCEDURES: Different measurements recorded on two phantoms (Siemens phantom, Comac phantom) were evaluated on images taken with the Somatom VolumeZoom (Siemens Medical Solutions, Erlangen, Germany) and the NewTom 9000 (NIM s.r.l., Verona, Italy) in order to calculate a calibration curve. The spatial relationships of six sample cylinders and the repositioning from four pig skull halves relative to adjacent defined anatomical structures were assessed by means of three-dimensional visualization software. The calibration curves for computer tomography (CT) and cone beam computer tomography (CBCT) using the Siemens phantom showed linear correlation in both modalities between the Hounsfield Units (HU) and bone morphology. A correction factor for CBCT was calculated. Exact information about the micromorphology of the bone cylinders was only available using of micro computer tomography. Cone-beam computer tomography is a suitable choice for analysing bone mass, but, it does not give any information about bone quality. 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. An ex vivo mechanical evaluation of single versus double semitubular plate fixation of a transverse distal-third scapular osteotomy in the dog.

    PubMed

    Mair, Jacqueline J; Belkoff, Stephen M; Boudrieau, Randy J

    2003-01-01

    To compare single versus double semitubular plate fixation for scapular body fractures. Ex vivo mechanical study. Eighteen paired cadaveric canine scapulae. Transverse scapular body osteotomies were created in the distal third of 18 pairs of scapulae. One scapula of each pair was repaired with a single plate, whereas the contralateral scapula was repaired with 2 plates. Initial strength and stiffness of the constructs were measured in 10 pairs of scapulae. Eight pairs of scapulae underwent cyclic loading and then were subjected to failure testing. Double-plate fixation was significantly stronger (3,899 +/- 632 N) but not stiffer (614 +/- 130 N/mm) than the single-plate fixation (3,238 +/- 935 N and 537 +/- 202 N/mm, respectively). Cyclic loading variables were not significantly different between the 2 methods of fixation. After cyclic loading, double-plate fixation was significantly stronger (2,916 +/- 618 N) than single-plate fixation (2,347 +/- 495 N). There was no significant difference (P =.11) in stiffness between double- versus single-plate fixations: 734 +/- 247 N/mm and 595 +/- 139 N/mm, respectively. Double-plate fixation was generally stronger and stiffer than single-plate fixation. Because all constructs failed at loads that greatly exceeded those estimated to occur clinically, any difference between the 2 methods of fixation probably is not clinically relevant. Single-plate fixation may be of sufficient strength for fixation of scapular body fractures. Copyright 2003 by The American College of Veterinary Surgeons

  13. Examination of Scanning Electron Microscope and Computed Tomography Images of PICA

    NASA Technical Reports Server (NTRS)

    Lawson, John W.; Stackpoole, Margaret M.; Shklover, Valery

    2010-01-01

    Micrographs of PICA (Phenolic Impregnated Carbon Ablator) taken using a Scanning Electron Microscope (SEM) and 3D images taken with a Computed Tomography (CT) system are examined. PICA is a carbon fiber based composite (Fiberform ) with a phenolic polymer matrix. The micrographs are taken at different surface depths and at different magnifications in a sample after arc jet testing and show different levels of oxidative removal of the charred matrix (Figs 1 though 13). CT scans, courtesy of Xradia, Inc. of Concord CA, were captured for samples of virgin PICA, charred PICA and raw Fiberform (Fig. 14). We use these images to calculate the thermal conductivity (TC) of these materials using correlation function (CF) methods. CF methods give a mathematical description of how one material is embedded in another and is thus ideally suited for modeling composites like PICA. We will evaluate how the TC of the materials changes as a function of surface depth. This work is in collaboration with ETH-Zurich, which has expertise in high temperature materials and TC modeling (including CF methods).

  14. Characterization of air-coupled ultrasound transducers in the frequency range 40 kHz-2 mHz using light diffraction tomography.

    PubMed

    Almqvist, M; Holm, A; Persson, H W; Lindström, K

    2000-01-01

    The aim of this work was to show the applicability of light diffraction tomography on airborne ultrasound in the frequency range 40 kHz-2 MHz. Seven different air-coupled transducers were measured to show the method's performance regarding linearity, absolute pressure measurements, phase measurements, frequency response, S/N ratio and spatial resolution. A calibrated microphone and the pulse-echo method were used to evaluate the results. The absolute measurements agreed within the calibrated microphone's uncertainty range. Pulse waveforms and corresponding FFT diagrams show the method's higher bandwidth compared with the microphone. Further, the method offers non-perturbing measurements with high spatial resolution, which was especially advantageous for measurements close to the transducer surfaces. The S/N ratio was higher than or in the same range as that of the two comparison methods.

  15. Obtaining 3D Chemical Maps by Energy Filtered Transmission Electron Microscopy Tomography.

    PubMed

    Roiban, Lucian; Sorbier, Loïc; Hirlimann, Charles; Ersen, Ovidiu

    2018-06-09

    Energy filtered transmission electron microscopy tomography (EFTEM tomography) can provide three-dimensional (3D) chemical maps of materials at a nanometric scale. EFTEM tomography can separate chemical elements that are very difficult to distinguish using other imaging techniques. The experimental protocol described here shows how to create 3D chemical maps to understand the chemical distribution and morphology of a material. Sample preparation steps for data segmentation are presented. This protocol permits the 3D distribution analysis of chemical elements in a nanometric sample. However, it should be noted that currently, the 3D chemical maps can only be generated for samples that are not beam sensitive, since the recording of filtered images requires long exposure times to an intense electron beam. The protocol was applied to quantify the chemical distribution of the components of two different heterogeneous catalyst supports. In the first study, the chemical distribution of aluminum and titanium in titania-alumina supports was analyzed. The samples were prepared using the swing-pH method. In the second, the chemical distribution of aluminum and silicon in silica-alumina supports that were prepared using the sol-powder and mechanical mixture methods was examined.

  16. Probing the structure of heterogeneous diluted materials by diffraction tomography.

    PubMed

    Bleuet, Pierre; Welcomme, Eléonore; Dooryhée, Eric; Susini, Jean; Hodeau, Jean-Louis; Walter, Philippe

    2008-06-01

    The advent of nanosciences calls for the development of local structural probes, in particular to characterize ill-ordered or heterogeneous materials. Furthermore, because materials properties are often related to their heterogeneity and the hierarchical arrangement of their structure, different structural probes covering a wide range of scales are required. X-ray diffraction is one of the prime structural methods but suffers from a relatively poor detection limit, whereas transmission electron analysis involves destructive sample preparation. Here we show the potential of coupling pencil-beam tomography with X-ray diffraction to examine unidentified phases in nanomaterials and polycrystalline materials. The demonstration is carried out on a high-pressure pellet containing several carbon phases and on a heterogeneous powder containing chalcedony and iron pigments. The present method enables a non-invasive structural refinement with a weight sensitivity of one part per thousand. It enables the extraction of the scattering patterns of amorphous and crystalline compounds with similar atomic densities and compositions. Furthermore, such a diffraction-tomography experiment can be carried out simultaneously with X-ray fluorescence, Compton and absorption tomographies, enabling a multimodal analysis of prime importance in materials science, chemistry, geology, environmental science, medical science, palaeontology and cultural heritage.

  17. Anaerobic Threshold and Salivary α-amylase during Incremental Exercise.

    PubMed

    Akizuki, Kazunori; Yazaki, Syouichirou; Echizenya, Yuki; Ohashi, Yukari

    2014-07-01

    [Purpose] The purpose of this study was to clarify the validity of salivary α-amylase as a method of quickly estimating anaerobic threshold and to establish the relationship between salivary α-amylase and double-product breakpoint in order to create a way to adjust exercise intensity to a safe and effective range. [Subjects and Methods] Eleven healthy young adults performed an incremental exercise test using a cycle ergometer. During the incremental exercise test, oxygen consumption, carbon dioxide production, and ventilatory equivalent were measured using a breath-by-breath gas analyzer. Systolic blood pressure and heart rate were measured to calculate the double product, from which double-product breakpoint was determined. Salivary α-amylase was measured to calculate the salivary threshold. [Results] One-way ANOVA revealed no significant differences among workloads at the anaerobic threshold, double-product breakpoint, and salivary threshold. Significant correlations were found between anaerobic threshold and salivary threshold and between anaerobic threshold and double-product breakpoint. [Conclusion] As a method for estimating anaerobic threshold, salivary threshold was as good as or better than determination of double-product breakpoint because the correlation between anaerobic threshold and salivary threshold was higher than the correlation between anaerobic threshold and double-product breakpoint. Therefore, salivary threshold is a useful index of anaerobic threshold during an incremental workload.

  18. Soft x-ray holographic tomography for biological specimens

    NASA Astrophysics Data System (ADS)

    Gao, Hongyi; Chen, Jianwen; Xie, Honglan; Li, Ruxin; Xu, Zhizhan; Jiang, Shiping; Zhang, Yuxuan

    2003-10-01

    In this paper, we present some experimental results on X -ray holography, holographic tomography, and a new holographic tomography method called pre-amplified holographic tomography is proposed. Due to the shorter wavelength and the larger penetration depths, X-rays provide the potential of higher resolution in imaging techniques, and have the ability to image intact, living, hydrated cells w ithout slicing, dehydration, chemical fixation or stain. Recently, using X-ray source in National Synchrotron Radiation Laboratory in Hefei, we have successfully performed some soft X-ray holography experiments on biological specimen. The specimens used in the experiments was the garlic clove epidermis, we got their X-ray hologram, and then reconstructed them by computer programs, the feature of the cell walls, the nuclei and some cytoplasm were clearly resolved. However, there still exist some problems in realization of practical 3D microscopic imaging due to the near-unity refractive index of the matter. There is no X-ray optics having a sufficient high numerical aperture to achieve a depth resolution that is comparable to the transverse resolution. On the other hand, computer tomography needs a record of hundreds of views of the test object at different angles for high resolution. This is because the number of views required for a densely packed object is equal to the object radius divided by the desired depth resolution. Clearly, it is impractical for a radiation-sensitive biological specimen. Moreover, the X-ray diffraction effect makes projection data blur, this badly degrades the resolution of the reconstructed image. In order to observe 3D structure of the biological specimens, McNulty proposed a new method for 3D imaging called "holographic tomography (HT)" in which several holograms of the specimen are recorded from various illumination directions and combined in the reconstruction step. This permits the specimens to be sampled over a wide range of spatial frequencies to improve the depth resolution. In NSRL, we performed soft X-ray holographic tomography experiments. The specimen was the spider filaments and PM M A as recording medium. By 3D CT reconstruction of the projection data, three dimensional density distribution of the specimen was obtained. Also, we developed a new X-ray holographic tomography m ethod called pre-amplified holographic tomography. The method permits a digital real-time 3D reconstruction with high-resolution and a simple and compact experimental setup as well.

  19. Usefulness of positron emission tomography in primary intestinal follicular lymphoma

    PubMed Central

    Tari, Akira; Asaoku, Hideki; Kunihiro, Masaki; Tanaka, Shinji; Yoshino, Tadashi

    2013-01-01

    Double-balloon enteroscopy (DBE) and video capsule endoscopy are useful for the diagnosis of lymphoma in the small intestine. However, DBE cannot be safely performed in cases with passage disturbance due to wall thickening and stenosis. Additionally, video capsule endoscopy cannot be performed in such cases because of the risk of retention. Here, we report 4 cases of primary follicular lymphoma of the gastrointestinal tract that could be detected using 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (PET-CT). The endoscopic findings of these 4 cases included lesions with wall thickening, which comprised macroscopically clusters of nodules, dense clusters of whitish granules or small nodules, fold thickening and ulcers with irregular margins that occupied the whole lumen with edematous mucosa. All patients fulfilled the World Health Organization grade 1 criteria. 18F-fluorodeoxyglucose PET-CT can help predict the risks that may result from certain endoscopic examinations, such as DBE and video capsule endoscopy. PMID:23569346

  20. Hardening mechanisms in olivine single crystal deformed at 1090 °C: an electron tomography study

    NASA Astrophysics Data System (ADS)

    Mussi, Alexandre; Cordier, Patrick; Demouchy, Sylvie; Hue, Benoit

    2017-11-01

    The dislocation microstructures in a single crystal of olivine deformed experimentally in uniaxial compression at 1090 °C and under a confining pressure of 300 MPa, have been investigated by transmission electron tomography in order to better understand deformation mechanisms at the microscale relevant for lithospheric mantle deformations. Investigation by electron tomography reveals microstructures, which are more complex than previously described, composed of ? and ? dislocations commonly exhibiting 3D configurations. Numerous mechanisms such as climb, cross-slip, double cross-slip as well as interactions like junction formations and collinear annihilations are the source of this complexity. The diversity observed advocates for microscale deformation of olivine significantly less simple than classic dislocation creep reported in metals or ice close to melting temperature. Deciphering mechanism of hardening in olivine at temperatures where ionic diffusion is slow and is then expected to play very little role is crucial to better understand and thus model deformation at larger scale and at temperatures (900-1100 °C) highly relevant for the lithospheric mantle.

  1. Improved patient size estimates for accurate dose calculations in abdomen computed tomography

    NASA Astrophysics Data System (ADS)

    Lee, Chang-Lae

    2017-07-01

    The radiation dose of CT (computed tomography) is generally represented by the CTDI (CT dose index). CTDI, however, does not accurately predict the actual patient doses for different human body sizes because it relies on a cylinder-shaped head (diameter : 16 cm) and body (diameter : 32 cm) phantom. The purpose of this study was to eliminate the drawbacks of the conventional CTDI and to provide more accurate radiation dose information. Projection radiographs were obtained from water cylinder phantoms of various sizes, and the sizes of the water cylinder phantoms were calculated and verified using attenuation profiles. The effective diameter was also calculated using the attenuation of the abdominal projection radiographs of 10 patients. When the results of the attenuation-based method and the geometry-based method shown were compared with the results of the reconstructed-axial-CT-image-based method, the effective diameter of the attenuation-based method was found to be similar to the effective diameter of the reconstructed-axial-CT-image-based method, with a difference of less than 3.8%, but the geometry-based method showed a difference of less than 11.4%. This paper proposes a new method of accurately computing the radiation dose of CT based on the patient sizes. This method computes and provides the exact patient dose before the CT scan, and can therefore be effectively used for imaging and dose control.

  2. [18F]-Fluoromisonidazole Positron Emission Tomography/Computed Tomography Visualization of Tumor Hypoxia in Patients With Chordoma of the Mobile and Sacrococcygeal Spine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheney, Matthew D., E-mail: mcheney@lroc.harvard.edu; Chen, Yen-Lin; Lim, Ruth

    2014-12-01

    Purpose: To investigate [18F]-fluoromisonidazole positron emission tomography/computed tomography (FMISO-PET/CT) detection of targetable hypoxic subvolumes (HSVs) in chordoma of the mobile or sacrococcygeal spine. Methods and Materials: A prospective, pilot study of 20 patients with primary or locally recurrent chordoma of the mobile or sacrococcygeal spine treated with proton or combined proton/photon radiation therapy (RT) with or without surgery was completed. The FMISO-PET/CT was performed before RT and after 19.8-34.2 GyRBE (relative biologic effectiveness). Gross tumor volumes were delineated and HSVs defined including voxels with standardized uptake values ≥1.4 times the muscle mean. Clinical characteristics and treatments received were compared betweenmore » patients with and without HSVs. Results: The FMISO-PET/CT detected HSVs in 12 of 20 patients (60%). Baseline and interval HSV spatial concordance varied (0%-94%). Eight HSVs were sufficiently large (≥5 cm{sup 3}) to potentially allow an intensity modulated proton therapy boost. Patients with HSVs had significantly larger gross tumor volumes (median 410.0 cm{sup 3} vs 63.4 cm{sup 3}; P=.02) and were significantly more likely to have stage T2 tumors (5 of 12 vs 0 of 8; P=.04). After a median follow-up of 1.8 years (range, 0.2-4.4 years), a local recurrence has yet to be observed. Three patients developed metastatic disease, 2 with HSVs. Conclusions: Detection of targetable HSVs by FMISO-PET/CT within patients undergoing RT with or without surgery for treatment of chordoma of the mobile and sacrococcygeal spine is feasible. The study's inability to attribute interval HSV changes to treatment, rapidly changing hypoxic physiology, or imaging inconsistencies is a limitation. Further study of double-baseline FMISO-PET/CT and hypoxia-directed RT dose escalation, particularly in patients at high risk for local recurrence, is warranted.« less

  3. 2-D Fused Image Reconstruction approach for Microwave Tomography: a theoretical assessment using FDTD Model.

    PubMed

    Bindu, G; Semenov, S

    2013-01-01

    This paper describes an efficient two-dimensional fused image reconstruction approach for Microwave Tomography (MWT). Finite Difference Time Domain (FDTD) models were created for a viable MWT experimental system having the transceivers modelled using thin wire approximation with resistive voltage sources. Born Iterative and Distorted Born Iterative methods have been employed for image reconstruction with the extremity imaging being done using a differential imaging technique. The forward solver in the imaging algorithm employs the FDTD method of solving the time domain Maxwell's equations with the regularisation parameter computed using a stochastic approach. The algorithm is tested with 10% noise inclusion and successful image reconstruction has been shown implying its robustness.

  4. Accurate traveltime computation in complex anisotropic media with discontinuous Galerkin method

    NASA Astrophysics Data System (ADS)

    Le Bouteiller, P.; Benjemaa, M.; Métivier, L.; Virieux, J.

    2017-12-01

    Travel time computation is of major interest for a large range of geophysical applications, among which source localization and characterization, phase identification, data windowing and tomography, from decametric scale up to global Earth scale.Ray-tracing tools, being essentially 1D Lagrangian integration along a path, have been used for their efficiency but present some drawbacks, such as a rather difficult control of the medium sampling. Moreover, they do not provide answers in shadow zones. Eikonal solvers, based on an Eulerian approach, have attracted attention in seismology with the pioneering work of Vidale (1988), while such approach has been proposed earlier by Riznichenko (1946). They have been used now for first-arrival travel-time tomography at various scales (Podvin & Lecomte (1991). The framework for solving this non-linear partial differential equation is now well understood and various finite-difference approaches have been proposed, essentially for smooth media. We propose a novel finite element approach which builds a precise solution for strongly heterogeneous anisotropic medium (still in the limit of Eikonal validity). The discontinuous Galerkin method we have developed allows local refinement of the mesh and local high orders of interpolation inside elements. High precision of the travel times and its spatial derivatives is obtained through this formulation. This finite element method also honors boundary conditions, such as complex topographies and absorbing boundaries for mimicking an infinite medium. Applications from travel-time tomography, slope tomography are expected, but also for migration and take-off angles estimation, thanks to the accuracy obtained when computing first-arrival times.References:Podvin, P. and Lecomte, I., 1991. Finite difference computation of traveltimes in very contrasted velocity model: a massively parallel approach and its associated tools, Geophys. J. Int., 105, 271-284.Riznichenko, Y., 1946. Geometrical seismics of layered media, Trudy Inst. Theor. Geophysics, Vol II, Moscow (in Russian).Vidale, J., 1988. Finite-difference calculation of travel times, Bull. seism. Soc. Am., 78, 2062-2076.

  5. Objective-function hybridization in adjoint seismic tomography

    NASA Astrophysics Data System (ADS)

    Yuan, Yanhua O.; Bozdaǧ, Ebru; Simons, Frederik J.; Gao, Fuchun

    2017-04-01

    Seismic tomography is at the threshold of a new era of massive data sets. Improving the resolution and accuracy of the estimated Earth structure by assimilating as much information as possible from every seismogram, remains a challenge. We propose the use of the "exponentiated phase'', a type of measurement that robustly captures the information contained in the variation of phase with time in the seismogram. We explore its performance in both conventional and double-difference (Yuan, Simons & Tromp, Geophys. J. Intern, 2016) adjoint seismic tomography. We introduce a hybrid approach to combine different objective functions, taking advantage of both conventional and our new measurements. We initially focus on phase measurements in global tomography. Cross-correlation measurements are generally tailored by window selection algorithms, such as FLEXWIN, to balance amplitude differences between seismic phases. However, within selection windows, such measurements still favor the larger-amplitude phases. It is also difficult to select all usable portions of the seismogram in an optimal way, such that much information may be lost, particularly the scattered waves. Time-continuous phase measurements, which associate a time shift with each point in time, have the potential to extract information from every wiggle in the seismogram without cutting it into small pieces. One such type of measurement is the instantaneous phase (Bozdaǧ, Trampert & Tromp, Geophys. J. Intern, 2011), which thus far has not been implemented in realistic seismic-tomography experiments, given how difficult the computation of phase can sometimes be. The exponentiated phase, on the other hand, is computed on the basis of the normalized analytic signal, does not need an explicit measure of phase, and is thus much easier to implement, and more practical for real-world applications. Both types of measurements carry comparable structural information when direct measurements of the phase are not wrapped. To deal with cycle skips, we use the exponentiated phase to take into account relatively small-magnitude scattered waves at long periods, while using cross-correlation measurements on windows determined by FLEXWIN to select distinct body-wave arrivals without complicating measurements due to non-linearities at short periods. We present synthetic experiments to show how exponentiated-phase, cross-correlation measurements, and their hybridization affect tomographic results. We demonstrate the use of hybrid measurements on teleseismic seismograms, in which surface waves are prominent, for continental and global seismic imaging. It is clear that the exponentiated-phase measurements behave well and provide a better representation of the smaller phases in the adjoint sources required for the computation of the misfit gradient. The combination of two different types of phase measurements in a hybrid approach moves us towards using all of the available information in a data set, addressing data quality and measurement challenges simultaneously, while negligibly affecting computation time.

  6. Not simply more of the same: distinguishing between patient heterogeneity and parameter uncertainty.

    PubMed

    Vemer, Pepijn; Goossens, Lucas M A; Rutten-van Mölken, Maureen P M H

    2014-11-01

    In cost-effectiveness (CE) Markov models, heterogeneity in the patient population is not automatically taken into account. We aimed to compare methods of dealing with heterogeneity on estimates of CE, using a case study in chronic obstructive pulmonary disease (COPD). We first present a probabilistic sensitivity analysis (PSA) in which we sampled only from distributions representing parameter uncertainty. This ignores any heterogeneity. Next, we explored heterogeneity by presenting results for subgroups, using a method that samples parameter uncertainty simultaneously with heterogeneity in a single-loop PSA. Finally, we distinguished parameter uncertainty from heterogeneity in a double-loop PSA by performing a nested simulation within each PSA iteration. Point estimates and uncertainty differed substantially between methods. The incremental CE ratio (ICER) ranged from € 4900 to € 13,800. The single-loop PSA led to a substantially different shape of the CE plane and an overestimation of the uncertainty compared with the other 3 methods. The CE plane for the double-loop PSA showed substantially less uncertainty and a stronger negative correlation between the difference in costs and the difference in effects compared with the other methods. This came at the cost of higher calculation times. Not accounting for heterogeneity, subgroup analysis and the double-loop PSA can be viable options, depending on the decision makers' information needs. The single-loop PSA should not be used in CE research. It disregards the fundamental differences between heterogeneity and sampling uncertainty and overestimates uncertainty as a result. © The Author(s) 2014.

  7. Double-survey estimates of bald eagle populations in Oregon

    USGS Publications Warehouse

    Anthony, R.G.; Garrett, Monte G.; Isaacs, F.B.

    1999-01-01

    The literature on abundance of birds of prey is almost devoid of population estimates with statistical rigor. Therefore, we surveyed bald eagle (Haliaeetus leucocephalus) populations on the Crooked and lower Columbia rivers of Oregon and used the double-survey method to estimate populations and sighting probabilities for different survey methods (aerial, boat, vehicle) and bald eagle ages (adults vs. subadults). Sighting probabilities were consistently 20%. The results revealed variable and negative bias (percent relative bias = -9 to -70%) of direct counts and emphasized the importance of estimating populations where some measure of precision and ability to conduct inference tests are available. We recommend use of the double-survey method to estimate abundance of bald eagle populations and other raptors in open habitats.

  8. Combined optical coherence tomography and hyper-spectral imaging

    NASA Astrophysics Data System (ADS)

    Attendu, Xavier; Guay-Lord, Robin; Strupler, Mathias; Godbout, Nicolas; Boudoux, Caroline

    2017-02-01

    In this proceeding we demonstrate a system combining optical coherence tomography (OCT) and hyper-spectral imaging (HSI) into a single dual-clad fiber (DCF). Combining these modalities gives access to the sample morphology through OCT and to its molecular content through HSI. Both modalities have their illumination through the fiber core. The OCT is then collected through the core while the HSI is collected through the inner cladding of the DCF. A double-clad fiber coupler (DCFC) is used to address both channels separately. A scanning spectral filter was developed to successively inject narrow spectral bands of visible light into the fiber core and sweep across the entire visible spectrum. This allows for rapid HSI acquisition and high miniaturization potential.

  9. Optimized x-ray source scanning trajectories for iterative reconstruction in high cone-angle tomography

    NASA Astrophysics Data System (ADS)

    Kingston, Andrew M.; Myers, Glenn R.; Latham, Shane J.; Li, Heyang; Veldkamp, Jan P.; Sheppard, Adrian P.

    2016-10-01

    With the GPU computing becoming main-stream, iterative tomographic reconstruction (IR) is becoming a com- putationally viable alternative to traditional single-shot analytical methods such as filtered back-projection. IR liberates one from the continuous X-ray source trajectories required for analytical reconstruction. We present a family of novel X-ray source trajectories for large-angle CBCT. These discrete (sparsely sampled) trajectories optimally fill the space of possible source locations by maximising the degree of mutually independent information. They satisfy a discrete equivalent of Tuy's sufficiency condition and allow high cone-angle (high-flux) tomog- raphy. The highly isotropic nature of the trajectory has several advantages: (1) The average source distance is approximately constant throughout the reconstruction volume, thus avoiding the differential-magnification artefacts that plague high cone-angle helical computed tomography; (2) Reduced streaking artifacts due to e.g. X-ray beam-hardening; (3) Misalignment and component motion manifests as blur in the tomogram rather than double-edges, which is easier to automatically correct; (4) An approximately shift-invariant point-spread-function which enables filtering as a pre-conditioner to speed IR convergence. We describe these space-filling trajectories and demonstrate their above-mentioned properties compared with a traditional helical trajectories.

  10. Evaluation of Root Canal Configuration of Mandibular First Molars in a Palestinian Population by Using Cone-Beam Computed Tomography: An Ex Vivo Study

    PubMed Central

    Mukhaimer, Raed Hakam

    2014-01-01

    Aim. The purpose of this study was to investigate the number of canals and variations in root canal configuration in the mandibular permanent first molar teeth of a Palestinian population using cone-beam computed tomography (CBCT). Methods. A sample of 320 extracted double-rooted mandibular permanent first molars from Palestinian population was collected for this study and scanned with CBCT scanner. The following observations were made: number of root canals per root and canal configuration in each root based on Vertucci's classification. Results. Of the 320 mandibular first molars analyzed, 174 (54.4%) had three canals, 132 teeth (41.3%) had four canals, and only four teeth had two canals. The most common canal configuration in the mesial roots was Vertucci type IV (53.8%) followed by type II (38.8%). In the distal roots, the most prevalent canal configuration was Vertucci type I (57.5%) followed by type II ( 22.5%) and type III (10.6%). Conclusion. Our results showed that the number of canals and canal configuration in Palestinian population were consistent with previously reported data. The present study also indicates that CBCT is helpful as a diagnostic tool for the investigation of root canal morphology. PMID:27379321

  11. 4D in situ visualization of electrode morphology changes during accelerated degradation in fuel cells by X-ray computed tomography

    NASA Astrophysics Data System (ADS)

    White, Robin T.; Wu, Alex; Najm, Marina; Orfino, Francesco P.; Dutta, Monica; Kjeang, Erik

    2017-05-01

    A four-dimensional visualization approach, featuring three dimensions in space and one dimension in time, is proposed to study local electrode degradation effects during voltage cycling in fuel cells. Non-invasive in situ micro X-ray computed tomography (XCT) with a custom fuel cell fixture is utilized to track the same cathode catalyst layer domain throughout various degradation times from beginning-of-life (BOL) to end-of-life (EOL). With this unique approach, new information regarding damage features and trends are revealed, including crack propagation and catalyst layer thinning being quantified by means of image processing and analysis methods. Degradation heterogeneities as a result of local environmental variations under land and channel are also explored, with a higher structural degradation rate under channels being observed. Density and compositional changes resulting from carbon corrosion and catalyst layer collapse and thinning are observed by changes in relative X-ray attenuation from BOL to EOL, which also indicate possible vulnerable regions where crack initiation and propagation may occur. Electrochemical diagnostics and morphological features observed by micro-XCT are correlated by additionally collecting effective catalyst surface area, double layer capacitance, and polarization curves prior to imaging at various stages of degradation.

  12. Modeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectors

    NASA Astrophysics Data System (ADS)

    Ozsahin, I.; Unlu, M. Z.

    2014-03-01

    Breast cancer is the most common leading cause of cancer death among women. Positron Emission Tomography (PET) Mammography, also known as Positron Emission Mammography (PEM), is a method for imaging primary breast cancer. Over the past few years, PEMs based on scintillation crystals dramatically increased their importance in diagnosis and treatment of early stage breast cancer. However, these detectors have significant limitations like poor energy resolution resulting with false-negative result (missed cancer), and false-positive result which leads to suspecting cancer and suggests an unnecessary biopsy. In this work, a PEM scanner based on CdTe strip detectors is simulated via the Monte Carlo method and evaluated in terms of its spatial resolution, sensitivity, and image quality. The spatial resolution is found to be ~ 1 mm in all three directions. The results also show that CdTe strip detectors based PEM scanner can produce high resolution images for early diagnosis of breast cancer.

  13. Long Term Non-Invasive Imaging of Embryonic Stem Cells Using Reporter Genes

    PubMed Central

    Sun, Ning; Lee, Andrew; Wu, Joseph C.

    2013-01-01

    Development of non-invasive and accurate methods to track cell fate following delivery will greatly expedite transition of embryonic stem (ES) cell therapy to the clinic. Here we describe a protocol for the in vivo monitoring of stem cell survival, proliferation, and migration using reporter genes. We established stable ES cell lines constitutively expressing double fusion (DF; enhanced green fluorescent protein and firefly luciferase) or triple fusion (TF; monomeric red fluorescent protein, firefly luciferase, and herpes simplex virus thymidine kinase) reporter genes using lentiviral transduction. We used fluorescence activated cell sorting to purify these populations in vitro, bioluminescence imaging and positron emission tomography imaging to track them in vivo, and fluorescence immunostaining to confirm the results ex vivo. Unlike other methods of cell tracking such as iron particle and radionuclide labeling, reporter genes are inherited genetically and can be used to monitor cell proliferation and survival for the lifetime of transplanted cells and their progeny. PMID:19617890

  14. The finite layer method for modelling the sound transmission through double walls

    NASA Astrophysics Data System (ADS)

    Díaz-Cereceda, Cristina; Poblet-Puig, Jordi; Rodríguez-Ferran, Antonio

    2012-10-01

    The finite layer method (FLM) is presented as a discretisation technique for the computation of noise transmission through double walls. It combines a finite element method (FEM) discretisation in the direction perpendicular to the wall with trigonometric functions in the two in-plane directions. It is used for solving the Helmholtz equation at the cavity inside the double wall, while the wall leaves are modelled with the thin plate equation and solved with modal analysis. Other approaches to this problem are described here (and adapted where needed) in order to compare them with the FLM. They range from impedance models of the double wall behaviour to different numerical methods for solving the Helmholtz equation in the cavity. For the examples simulated in this work (impact noise and airborne sound transmission), the former are less accurate than the latter at low frequencies. The main advantage of FLM over the other discretisation techniques is the possibility of extending it to multilayered structures without changing the interpolation functions and with an affordable computational cost. This potential is illustrated with a calculation of the noise transmission through a multilayered structure: a double wall partially filled with absorbing material.

  15. Development of a database for the verification of trans-ionospheric remote sensing systems

    NASA Astrophysics Data System (ADS)

    Leitinger, R.

    2005-08-01

    Remote sensing systems need verification by means of in-situ data or by means of model data. In the case of ionospheric occultation inversion, ionosphere tomography and other imaging methods on the basis of satellite-to-ground or satellite-to-satellite electron content, the availability of in-situ data with adequate spatial and temporal co-location is a very rare case, indeed. Therefore the method of choice for verification is to produce artificial electron content data with realistic properties, subject these data to the inversion/retrieval method, compare the results with model data and apply a suitable type of “goodness of fit” classification. Inter-comparison of inversion/retrieval methods should be done with sets of artificial electron contents in a “blind” (or even “double blind”) way. The set up of a relevant database for the COST 271 Action is described. One part of the database will be made available to everyone interested in testing of inversion/retrieval methods. The artificial electron content data are calculated by means of large-scale models that are “modulated” in a realistic way to include smaller scale and dynamic structures, like troughs and traveling ionospheric disturbances.

  16. Image quality assessment of automatic three-segment MR attenuation correction vs. CT attenuation correction.

    PubMed

    Partovi, Sasan; Kohan, Andres; Gaeta, Chiara; Rubbert, Christian; Vercher-Conejero, Jose L; Jones, Robert S; O'Donnell, James K; Wojtylak, Patrick; Faulhaber, Peter

    2013-01-01

    The purpose of this study is to systematically evaluate the usefulness of Positron emission tomography/Magnetic resonance imaging (PET/MRI) images in a clinical setting by assessing the image quality of Positron emission tomography (PET) images using a three-segment MR attenuation correction (MRAC) versus the standard CT attenuation correction (CTAC). We prospectively studied 48 patients who had their clinically scheduled FDG-PET/CT followed by an FDG-PET/MRI. Three nuclear radiologists evaluated the image quality of CTAC vs. MRAC using a Likert scale (five-point scale). A two-sided, paired t-test was performed for comparison purposes. The image quality was further assessed by categorizing it as acceptable (equal to 4 and 5 on the five-point Likert scale) or unacceptable (equal to 1, 2, and 3 on the five-point Likert scale) quality using the McNemar test. When assessing the image quality using the Likert scale, one reader observed a significant difference between CTAC and MRAC (p=0.0015), whereas the other readers did not observe a difference (p=0.8924 and p=0.1880, respectively). When performing the grouping analysis, no significant difference was found between CTAC vs. MRAC for any of the readers (p=0.6137 for reader 1, p=1 for reader 2, and p=0.8137 for reader 3). All three readers more often reported artifacts on the MRAC images than on the CTAC images. There was no clinically significant difference in quality between PET images generated on a PET/MRI system and those from a Positron emission tomography/Computed tomography (PET/CT) system. PET images using the automatic three-segmented MR attenuation method provided diagnostic image quality. However, future research regarding the image quality obtained using different MR attenuation based methods is warranted before PET/MRI can be used clinically.

  17. Investigating the performance of wavelet neural networks in ionospheric tomography using IGS data over Europe

    NASA Astrophysics Data System (ADS)

    Ghaffari Razin, Mir Reza; Voosoghi, Behzad

    2017-04-01

    Ionospheric tomography is a very cost-effective method which is used frequently to modeling of electron density distributions. In this paper, residual minimization training neural network (RMTNN) is used in voxel based ionospheric tomography. Due to the use of wavelet neural network (WNN) with back-propagation (BP) algorithm in RMTNN method, the new method is named modified RMTNN (MRMTNN). To train the WNN with BP algorithm, two cost functions is defined: total and vertical cost functions. Using minimization of cost functions, temporal and spatial ionospheric variations is studied. The GPS measurements of the international GNSS service (IGS) in the central Europe have been used for constructing a 3-D image of the electron density. Three days (2009.04.15, 2011.07.20 and 2013.06.01) with different solar activity index is used for the processing. To validate and better assess reliability of the proposed method, 4 ionosonde and 3 testing stations have been used. Also the results of MRMTNN has been compared to that of the RMTNN method, international reference ionosphere model 2012 (IRI-2012) and spherical cap harmonic (SCH) method as a local ionospheric model. The comparison of MRMTNN results with RMTNN, IRI-2012 and SCH models shows that the root mean square error (RMSE) and standard deviation of the proposed approach are superior to those of the traditional method.

  18. Global Adjoint Tomography: Next-Generation Models

    NASA Astrophysics Data System (ADS)

    Bozdag, Ebru; Lefebvre, Matthieu; Lei, Wenjie; Orsvuran, Ridvan; Peter, Daniel; Ruan, Youyi; Smith, James; Komatitsch, Dimitri; Tromp, Jeroen

    2017-04-01

    The first-generation global adjoint tomography model GLAD-M15 (Bozdag et al. 2016) is the result of 15 conjugate-gradient iterations based on GPU-accelerated spectral-element simulations of 3D wave propagation and Fréchet kernels. For simplicity, GLAD-M15 was constructed as an elastic model with transverse isotropy confined to the upper mantle. However, Earth's mantle and crust show significant evidence of anisotropy as a result of its composition and deformation. There may be different sources of seismic anisotropy affecting both body and surface waves. As a first attempt, we initially tackle with surface-wave anisotropy and proceed iterations using the same 253 earthquake data set used in GLAD-M15 with an emphasize on upper-mantle. Furthermore, we explore new misfits, such as double-difference measurements (Yuan et al. 2016), to better deal with the possible artifacts of the uneven distribution of seismic stations globally and minimize source uncertainties in structural inversions. We will present our observations with the initial results of azimuthally anisotropic inversions and also discuss the next generation global models with various parametrizations. Meanwhile our goal is to use all available seismic data in imaging. This however requires a solid framework to perform iterative adjoint tomography workflows with big data on supercomputers. We will talk about developments in adjoint tomography workflow from the need of defining new seismic and computational data formats (e.g., ASDF by Krischer et al. 2016, ADIOS by Liu et al. 2011) to developing new pre- and post-processing tools together with experimenting workflow management tools, such as Pegasus (Deelman et al. 2015). All our simulations are performed on Oak Ridge National Laboratory's Cray XK7 "Titan" system. Our ultimate aim is to get ready to harness ORNL's next-generation supercomputer "Summit", an IBM with Power-9 CPUs and NVIDIA Volta GPU accelerators, to be ready by 2018 which will enable us to reduce the shortest period in our global simulations from 17 s to 9 s, and exascale systems will reduce this further to just a few seconds.

  19. Status of the LIA-2. Double-pulse mode

    NASA Astrophysics Data System (ADS)

    Starostenko, D. A.; Akimov, A. V.; Bak, P. A.; Batazova, M. A.; Batrakov, A. M.; Boimelshtein, Yu. M.; Bolkhovityanov, D. Yu.; Eliseev, A. A.; Korepanov, A. A.; Kuznetsov, G. I.; Kulenko, Ya. V.; Logatchev, P. V.; Ottmar, A. V.; Pavlenko, A. V.; Pavlov, O. A.; Panov, A. N.; Pachkov, A. A.; Fatkin, G. A.; Akhmetov, A. R.; Kolesnikov, P. A.; Nikitin, O. A.; Petrov, D. V.

    2016-12-01

    The LIA-2 linear induction accelerator has been designed in the Budker Institute of Nuclear Physics as an electron-beam injector for a promising 20-MeV induction accelerator intended for tomography. Owing to the results of the first tests, it was decided to use the injector as an independent X-ray installation [1]. In 2014, the high-voltage power supply system of the LIA-2 was upgraded and tuned. The accelerator operates stably in the one-pulse mode at energies of up to 1.7 MeV; in the double-pulse mode it operates at energies of up to 1.5 MeV. The inhomogeneity in energy in each pulse does not exceed ±0.5%.

  20. Designing torus-doubling solutions to discrete time systems by hybrid projective synchronization

    NASA Astrophysics Data System (ADS)

    Xie, Hui; Wen, Guilin

    2013-11-01

    Doubling of torus occurs in high dimensional nonlinear systems, which is related to a certain kind of typical second bifurcations. It is a nontrivial task to create a torus-doubling solution with desired dynamical properties based on the classical bifurcation theories. In this paper, dead-beat hybrid projective synchronization is employed to build a novel method for designing stable torus-doubling solutions into discrete time systems with proper properties to achieve the purpose of utilizing bifurcation solutions as well as avoiding the possible conflict of physical meaning of the created solution. Although anti-controls of bifurcation and chaos synchronizations are two different topics in nonlinear dynamics and control, the results imply that it is possible to develop some new interdisciplinary methods between chaos synchronization and anti-controls of bifurcations.

  1. Electrical capacitance volume tomography with high contrast dielectrics using a cuboid sensor geometry

    NASA Astrophysics Data System (ADS)

    Nurge, Mark A.

    2007-05-01

    An electrical capacitance volume tomography system has been created for use with a new image reconstruction algorithm capable of imaging high contrast dielectric distributions. The electrode geometry consists of two 4 × 4 parallel planes of copper conductors connected through custom built switch electronics to a commercially available capacitance to digital converter. Typical electrical capacitance tomography (ECT) systems rely solely on mutual capacitance readings to reconstruct images of dielectric distributions. This paper presents a method of reconstructing images of high contrast dielectric materials using only the self-capacitance measurements. By constraining the unknown dielectric material to one of two values, the inverse problem is no longer ill-determined. Resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminium structure inserted at different positions within the sensing region. Comparisons with standard two-dimensional ECT systems highlight the capabilities and limitations of the electronics and reconstruction algorithm.

  2. Electrical capacitance volume tomography of high contrast dielectrics using a cuboid geometry

    NASA Astrophysics Data System (ADS)

    Nurge, Mark A.

    An Electrical Capacitance Volume Tomography system has been created for use with a new image reconstruction algorithm capable of imaging high contrast dielectric distributions. The electrode geometry consists of two 4 x 4 parallel planes of copper conductors connected through custom built switch electronics to a commercially available capacitance to digital converter. Typical electrical capacitance tomography (ECT) systems rely solely on mutual capacitance readings to reconstruct images of dielectric distributions. This dissertation presents a method of reconstructing images of high contrast dielectric materials using only the self capacitance measurements. By constraining the unknown dielectric material to one of two values, the inverse problem is no longer ill-determined. Resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. Comparisons with standard two dimensional ECT systems highlight the capabilities and limitations of the electronics and reconstruction algorithm.

  3. A convolutional neural network approach to calibrating the rotation axis for X-ray computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xiaogang; De Carlo, Francesco; Phatak, Charudatta

    This paper presents an algorithm to calibrate the center-of-rotation for X-ray tomography by using a machine learning approach, the Convolutional Neural Network (CNN). The algorithm shows excellent accuracy from the evaluation of synthetic data with various noise ratios. It is further validated with experimental data of four different shale samples measured at the Advanced Photon Source and at the Swiss Light Source. The results are as good as those determined by visual inspection and show better robustness than conventional methods. CNN has also great potential forreducing or removingother artifacts caused by instrument instability, detector non-linearity,etc. An open-source toolbox, which integratesmore » the CNN methods described in this paper, is freely available through GitHub at tomography/xlearn and can be easily integrated into existing computational pipelines available at various synchrotron facilities. Source code, documentation and information on how to contribute are also provided.« less

  4. Virtopsy: postmortem imaging of laryngeal foreign bodies.

    PubMed

    Oesterhelweg, Lars; Bolliger, Stephan A; Thali, Michael J; Ross, Steffen

    2009-05-01

    Death from corpora aliena in the larynx is a well-known entity in forensic pathology. The correct diagnosis of this cause of death is difficult without an autopsy, and misdiagnoses by external examination alone are common. To determine the postmortem usefulness of modern imaging techniques in the diagnosis of foreign bodies in the larynx, multislice computed tomography, magnetic resonance imaging, and postmortem full-body computed tomography-angiography were performed. Three decedents with a suspected foreign body in the larynx underwent the 3 different imaging techniques before medicolegal autopsy. Multislice computed tomography has a high diagnostic value in the noninvasive localization of a foreign body and abnormalities in the larynx. The differentiation between neoplasm or soft foreign bodies (eg, food) is possible, but difficult, by unenhanced multislice computed tomography. By magnetic resonance imaging, the discrimination of the soft tissue structures and soft foreign bodies is much easier. In addition to the postmortem multislice computed tomography, the combination with postmortem angiography will increase the diagnostic value. Postmortem, cross-sectional imaging methods are highly valuable procedures for the noninvasive detection of corpora aliena in the larynx.

  5. Improvement of resolution in full-view linear-array photoacoustic computed tomography using a novel adaptive weighting method

    NASA Astrophysics Data System (ADS)

    Omidi, Parsa; Diop, Mamadou; Carson, Jeffrey; Nasiriavanaki, Mohammadreza

    2017-03-01

    Linear-array-based photoacoustic computed tomography is a popular methodology for deep and high resolution imaging. However, issues such as phase aberration, side-lobe effects, and propagation limitations deteriorate the resolution. The effect of phase aberration due to acoustic attenuation and constant assumption of the speed of sound (SoS) can be reduced by applying an adaptive weighting method such as the coherence factor (CF). Utilizing an adaptive beamforming algorithm such as the minimum variance (MV) can improve the resolution at the focal point by eliminating the side-lobes. Moreover, invisibility of directional objects emitting parallel to the detection plane, such as vessels and other absorbing structures stretched in the direction perpendicular to the detection plane can degrade resolution. In this study, we propose a full-view array level weighting algorithm in which different weighs are assigned to different positions of the linear array based on an orientation algorithm which uses the histogram of oriented gradient (HOG). Simulation results obtained from a synthetic phantom show the superior performance of the proposed method over the existing reconstruction methods.

  6. Landau-Zener-Stückelberg-Majorana interference in a 3D transmon driven by a chirped microwave

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Ming; Department of Physics and Astronomy, University of Kansas, Lawrence, Kansas 66045; Zhou, Yu

    2016-03-14

    By driving a 3D transmon with microwave fields, we generate an effective avoided energy-level crossing. Then we chirp microwave frequency, which is equivalent to driving the system through the avoided energy-level crossing by sweeping the avoided crossing. A double-passage chirp produces Landau-Zener-Stückelberg-Majorana (LZSM) interference that agree well with the numerical results, especially with the initial state being an eigen-energy state in the center of an avoided level crossing. A time-resolved state tomography measurement is performed in the evolution of LZSM interference, showing an experimental evidence for the dynamical evolution of quantum state. Our method is fully applicable to other quantummore » systems that contain no intrinsic avoided level crossing, providing an alternative approach for quantum control and quantum simulation.« less

  7. Arrival Time Tracking of Partially Resolved Acoustic Rays with Application to Ocean Acoustic Tomography

    DTIC Science & Technology

    1991-03-01

    ocean acoustic tomography. A straightforward method of arrival time estimation, based on locating the maximum value of an interpolated arrival, was...used with limited success for analysis of data from the December 1988 Monterey Bay Tomography Experiment. Close examination of the data revealed multiple...estimation of arrival times along an ocean acoustic ray path is an important component of ocean acoustic tomography. A straightforward method of arrival time

  8. Architecture and biogenesis of plus-strand RNA virus replication factories

    PubMed Central

    Paul, David; Bartenschlager, Ralf

    2013-01-01

    Plus-strand RNA virus replication occurs in tight association with cytoplasmic host cell membranes. Both, viral and cellular factors cooperatively generate distinct organelle-like structures, designated viral replication factories. This compartmentalization allows coordination of the different steps of the viral replication cycle, highly efficient genome replication and protection of the viral RNA from cellular defense mechanisms. Electron tomography studies conducted during the last couple of years revealed the three dimensional structure of numerous plus-strand RNA virus replication compartments and highlight morphological analogies between different virus families. Based on the morphology of virus-induced membrane rearrangements, we propose two separate subclasses: the invaginated vesicle/spherule type and the double membrane vesicle type. This review discusses common themes and distinct differences in the architecture of plus-strand RNA virus-induced membrane alterations and summarizes recent progress that has been made in understanding the complex interplay between viral and co-opted cellular factors in biogenesis and maintenance of plus-strand RNA virus replication factories. PMID:24175228

  9. Orthodontic soft-tissue parameters: a comparison of cone-beam computed tomography and the 3dMD imaging system.

    PubMed

    Metzger, Tasha E; Kula, Katherine S; Eckert, George J; Ghoneima, Ahmed A

    2013-11-01

    Orthodontists rely heavily on soft-tissue analysis to determine facial esthetics and treatment stability. The aim of this retrospective study was to determine the equivalence of soft-tissue measurements between the 3dMD imaging system (3dMD, Atlanta, Ga) and the segmented skin surface images derived from cone-beam computed tomography. Seventy preexisting 3dMD facial photographs and cone-beam computed tomography scans taken within minutes of each other for the same subjects were registered in 3 dimensions and superimposed using Vultus (3dMD) software. After reliability studies, 28 soft-tissue measurements were recorded with both imaging modalities and compared to analyze their equivalence. Intraclass correlation coefficients and Bland-Altman plots were used to assess interexaminer and intraexaminer repeatability and agreement. Summary statistics were calculated for all measurements. To demonstrate equivalence of the 2 methods, the difference needed a 95% confidence interval contained entirely within the equivalence limits defined by the repeatability results. Statistically significant differences were reported for the vermilion height, mouth width, total facial width, mouth symmetry, soft-tissue lip thickness, and eye symmetry. There are areas of nonequivalence between the 2 imaging methods; however, the differences are clinically acceptable from the orthodontic point of view. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  10. Collimator-free photon tomography

    DOEpatents

    Dilmanian, F.A.; Barbour, R.L.

    1998-10-06

    A method of uncollimated single photon emission computed tomography includes administering a radioisotope to a patient for producing gamma ray photons from a source inside the patient. Emissivity of the photons is measured externally of the patient with an uncollimated gamma camera at a plurality of measurement positions surrounding the patient for obtaining corresponding energy spectrums thereat. Photon emissivity at the plurality of measurement positions is predicted using an initial prediction of an image of the source. The predicted and measured photon emissivities are compared to obtain differences therebetween. Prediction and comparison is iterated by updating the image prediction until the differences are below a threshold for obtaining a final prediction of the source image. 6 figs.

  11. Detection of foreign body using fast thermoacoustic tomography with a multielement linear transducer array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nie Liming; Xing Da; Yang Diwu

    2007-04-23

    Current imaging modalities face challenges in clinical applications due to limitations in resolution or contrast. Microwave-induced thermoacoustic imaging may provide a complementary modality for medical imaging, particularly for detecting foreign objects due to their different absorption of electromagnetic radiation at specific frequencies. A thermoacoustic tomography system with a multielement linear transducer array was developed and used to detect foreign objects in tissue. Radiography and thermoacoustic images of objects with different electromagnetic properties, including glass, sand, and iron, were compared. The authors' results demonstrate that thermoacoustic imaging has the potential to become a fast method for surgical localization of occult foreignmore » objects.« less

  12. Assessment of Spectral-Domain Optical Coherence Tomography Findings in Three Cases of X-Linked Juvenile Retinoschisis in the Same Family.

    PubMed

    Doğuizi, Sibel; Şekeroğlu, Mehmet Ali; Çolak, Salih; Anayol, Mustafa Alpaslan; Yılmazbaş, Pelin

    2017-10-01

    X-linked juvenile retinoschisis (XLRS) is an X-linked hereditary retinal dystrophy characterized by splitting of the neurosensory retina. On fundus examination, the macula often has a spoke wheel appearance with foveal cystic lesions, and separation of the retinal layers is typical on spectral-domain optical coherence tomography (SD-OCT). Patients with XLRS can exhibit different clinical courses, stages, and SD-OCT findings, even among members of the same family. SD-OCT is an important imaging method that allows us to achieve more detailed information about XLRS. In this study, we report three patients in the same family who have different clinical features and SD-OCT findings.

  13. Tissue sensitive imaging and tomography without contrast agents for small animals with Timepix based detectors

    NASA Astrophysics Data System (ADS)

    Trojanova, E.; Schyns, L. E. J. R.; Dubois, L.; Jakubek, J.; Le Pape, A.; Sefc, L.; Sykora, V.; Turecek, D.; Uher, J.; Verhaegen, F.

    2017-01-01

    The tissue type resolving X-ray radiography and tomography can be performed even without contrast agents. The differences between soft tissue types such as kidney, muscles, fat, liver, brain and spleen were measured based on their spectral response. The Timepix based X-ray imaging detector WidePIX2×5 with 300 μm thick silicon sensors was used for most of the measurements presented in this work. These promising results are used for further optimizations of the detector technology and radiographic methods.

  14. Clinical cone beam computed tomography compared to high-resolution peripheral computed tomography in the assessment of distal radius bone.

    PubMed

    de Charry, C; Boutroy, S; Ellouz, R; Duboeuf, F; Chapurlat, R; Follet, H; Pialat, J B

    2016-10-01

    Clinical cone beam computed tomography (CBCT) was compared to high-resolution peripheral quantitative computed tomography (HR-pQCT) for the assessment of ex vivo radii. Strong correlations were found for geometry, volumetric density, and trabecular structure. Using CBCT, bone architecture assessment was feasible but compared to HR-pQCT, trabecular parameters were overestimated whereas cortical ones were underestimated. HR-pQCT is the most widely used technique to assess bone microarchitecture in vivo. Yet, this technology has been only applicable at peripheral sites, in only few research centers. Clinical CBCT is more widely available but quantitative assessment of the bone structure is usually not performed. We aimed to compare the assessment of bone structure with CBCT (NewTom 5G, QR, Verona, Italy) and HR-pQCT (XtremeCT, Scanco Medical AG, Brüttisellen, Switzerland). Twenty-four distal radius specimens were scanned with these two devices with a reconstructed voxel size of 75 μm for Newtom 5G and 82 μm for XtremeCT, respectively. A rescaling-registration scheme was used to define the common volume of interest. Cortical and trabecular compartments were separated using a semiautomated double contouring method. Density and microstructure were assessed with the HR-pQCT software on both modality images. Strong correlations were found for geometry parameters (r = 0.98-0.99), volumetric density (r = 0.91-0.99), and trabecular structure (r = 0.94-0.99), all p < 0.001. Correlations were lower for cortical microstructure (r = 0.80-0.89), p < 0.001. However, absolute differences were observed between modalities for all parameters, with an overestimation of the trabecular structure (trabecular number, 1.62 ± 0.37 vs. 1.47 ± 0.36 mm(-1)) and an underestimation of the cortical microstructure (cortical porosity, 3.3 ± 1.3 vs. 4.4 ± 1.4 %) assessed on CBCT images compared to HR-pQCT images. Clinical CBCT devices are able to analyze large portions of distal bones with good spatial resolution and limited irradiation. However, compared to dedicated HR-pQCT, the assessment of microarchitecture by NewTom 5G dental CBCT showed some discrepancies, for density measurements mainly. Further technical developments are required to reach optimal assessment of bone characteristics.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blume-Kohout, Robin J.; Gamble, John King; Nielsen, Erik

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. Wemore » describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.« less

  16. LONG-TERM RETROSPECTIVE ANALYSIS OF VISUAL ACUITY AND OPTICAL COHERENCE TOPOGRAPHIC CHANGES AFTER SINGLE VERSUS DOUBLE PEELING DURING VITRECTOMY FOR MACULAR EPIRETINAL MEMBRANES.

    PubMed

    Jung, Jesse J; Hoang, Quan V; Ridley-Lane, Megan L; Sebrow, Dov B; Dhrami-Gavazi, Elona; Chang, Stanley

    2016-11-01

    To determine the long-term effect of internal limiting membrane with associated epiretinal membrane (ERM) peeling versus single peeling alone in terms of best-corrected visual acuity and anatomical outcomes on spectral-domain optical coherence tomography. This retrospective comparative cohort study of patients who had follow-up of >1 year and underwent surgery for ERM by a single surgeon (S.C.) from January 1, 2008 to December 31, 2012 compared cases in which the internal limiting membrane was stained with brilliant blue G to facilitate double peeling (n = 42) and single peeling (n = 43) of the ERM alone for up to 3 years of follow-up. For continuous variables, an independent two-tailed t-test was performed. For binary variables, the Fisher's exact test was performed. Statistical significance was defined as P < 0.05. Eighty-five of 142 patients fit the inclusion criteria. At the last follow-up, the single-peeling group were more likely to have ERM remaining in the central fovea postoperatively (P = 0.0020, becoming significant by postoperative Year 1, P = 0.022) and less likely to develop inner retinal dimpling (P = 0.000, becoming significant by postoperative Month 3, P = 0.015). At 3 years, central foveal thickness had decreased in the single-peeling group by -136.9 µm and by -84.1 μm in the double-peeling group, which was not significantly different (P = 0.08). Mean best-corrected visual acuity improved in both the groups at all time points. There was no statistically significant difference between the 2 groups at 3 years (P = 0.44; single-peeling group, 0.32 ± 0.42, Snellen 20/42; double-peeling group, 0.23 ± 0.27, Snellen 20/34). Brilliant blue G-assisted internal limiting membrane peeling for ERM results in a more thorough removal of residual ERM around the paracentral fovea. However, there is no difference in long-term best-corrected visual acuity at 3 years and a greater likelihood of inner retinal dimpling.

  17. The design and performance of the nano-carbon based double layers flexible coating for tunable and high-efficiency microwave absorption

    NASA Astrophysics Data System (ADS)

    Zhang, Danfeng; Hao, Zhifeng; Qian, Yannan; Zeng, Bi; Zhu, Haiping; Wu, Qibai; Yan, Chengjie; Chen, Muyu

    2018-05-01

    Nanocarbon-based materials are outstanding microwave absorbers with good dielectric properties. In this study, double-layer silicone resin flexible absorbing coatings, composed of carbon-coated nickel nanoparticles (Ni@C) and carbon nanotubes (CNTs), with low loading and a total thickness of 2 mm, were prepared. The reflection loss (RL) of the double-layer absorbing coatings has measured for frequencies between 2 and 18 GHz using the Arch reflecting testing method. The effects of the thickness and electromagnetic parameters of each layer and of the layer sequence on the absorbing properties were investigated. It is found that the measured bandwidth (RL ≤ - 10 dB) of the optimum double-layer structure in our experiment range achieves 3.70 GHz. The results indicated that the double coating structure composed of different materials has greater synergistic absorption effect on impedance matching than that of same materials with different loading. The maximum RL of S1 (5 wt% CNTs)/S3 (60 wt% Ni@C) double-layer absorbing coating composed of different materials (S1 and S3) was larger than the one achieved using either S1 or S3 alone with the same thickness. This was because double-layer coating provided a suitable matching layer and improve the interfacial impedance. It was also shown that absorbing peak value and frequency position can be adjusted by double-layer coating structure.

  18. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    PubMed

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (p<0.01), as well as between IOL Master and digital photographs (p<0.01). There was no difference between SL-OCT and digital photographs (p>0.05). All measurements were correlated (Spearman p<0.001). Mean anterior chamber depth determined using the IOL-Master was 2.99 +/- 0.50 mm and by slit-lamp adapted optical coherence tomography was 2.56 +/- 0.46 mm. The difference was statistically significant (p<0.001). The correlation between the values was also statistically significant (Spearman, p<0.001). Automated measurements using IOL-Master yield constantly higher values than measurements based on direct eye visualization slit-lamp adapted optical coherence tomography and digital photographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.

  19. Multi-frequency electrical impedance tomography as a non-invasive tool to characterize and monitor crop root systems

    NASA Astrophysics Data System (ADS)

    Weigand, Maximilian; Kemna, Andreas

    2017-02-01

    A better understanding of root-soil interactions and associated processes is essential in achieving progress in crop breeding and management, prompting the need for high-resolution and non-destructive characterization methods. To date, such methods are still lacking or restricted by technical constraints, in particular the charactization and monitoring of root growth and function in the field. A promising technique in this respect is electrical impedance tomography (EIT), which utilizes low-frequency (< 1 kHz)- electrical conduction- and polarization properties in an imaging framework. It is well established that cells and cell clusters exhibit an electrical polarization response in alternating electric-current fields due to electrical double layers which form at cell membranes. This double layer is directly related to the electrical surface properties of the membrane, which in turn are influenced by nutrient dynamics (fluxes and concentrations on both sides of the membranes). Therefore, it can be assumed that the electrical polarization properties of roots are inherently related to ion uptake and translocation processes in the root systems. We hereby propose broadband (mHz to hundreds of Hz) multi-frequency EIT as a non-invasive methodological approach for the monitoring and physiological, i.e., functional, characterization of crop root systems. The approach combines the spatial-resolution capability of an imaging method with the diagnostic potential of electrical-impedance spectroscopy. The capability of multi-frequency EIT to characterize and monitor crop root systems was investigated in a rhizotron laboratory experiment, in which the root system of oilseed plants was monitored in a water-filled rhizotron, that is, in a nutrient-deprived environment. We found a low-frequency polarization response of the root system, which enabled the successful delineation of its spatial extension. The magnitude of the overall polarization response decreased along with the physiological decay of the root system due to the stress situation. Spectral polarization parameters, as derived from a pixel-based Debye decomposition analysis of the multi-frequency imaging results, reveal systematic changes in the spatial and spectral electrical response of the root system. In particular, quantified mean relaxation times (of the order of 10 ms) indicate changes in the length scales on which the polarization processes took place in the root system, as a response to the prolonged induced stress situation. Our results demonstrate that broadband EIT is a capable, non-invasive method to image root system extension as well as to monitor changes associated with the root physiological processes. Given its applicability on both laboratory and field scales, our results suggest an enormous potential of the method for the structural and functional imaging of root systems for various applications. This particularly holds for the field scale, where corresponding methods are highly desired but to date are lacking.

  20. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yidong, E-mail: yidongyang@med.miami.edu; Wang, Ken Kang-Hsin; Wong, John W.

    2015-04-15

    Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is tomore » develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.« less

  1. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    PubMed Central

    Yang, Yidong; Wang, Ken Kang-Hsin; Eslami, Sohrab; Iordachita, Iulian I.; Patterson, Michael S.; Wong, John W.

    2015-01-01

    Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems. PMID:25832060

  2. Behavioural impact of a double dopaminergic and serotonergic lesion in the non-human primate.

    PubMed

    Beaudoin-Gobert, Maude; Epinat, Justine; Météreau, Elise; Duperrier, Sandra; Neumane, Sara; Ballanger, Bénédicte; Lavenne, Franck; Liger, François; Tourvielle, Christian; Bonnefoi, Frédéric; Costes, Nicolas; Bars, Didier Le; Broussolle, Emmanuel; Thobois, Stéphane; Tremblay, Léon; Sgambato-Faure, Véronique

    2015-09-01

    Serotonergic (5-HT) neurons degenerate in Parkinson's disease. To determine the role of this 5-HT injury-besides the dopaminergic one in the parkinsonian symptomatology-we developed a new monkey model exhibiting a double dopaminergic/serotonergic lesion by sequentially using 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) and 3,4-methylenedioxy-N-methamphetamine (MDMA, better known as ecstasy). By positron emission tomography imaging and immunohistochemistry, we demonstrated that MDMA injured 5-HT nerve terminals in the brain of MPTP monkeys. Unexpectedly, this injury had no impact on tremor or on bradykinesia, but altered rigidity. It abolished the l-DOPA-induced dyskinesia and neuropsychiatric-like behaviours, without altering the anti-parkinsonian response. These data demonstrate that 5-HT fibres play a critical role in the expression of both motor and non-motor symptoms in Parkinson's disease, and highlight that an imbalance between the 5-HT and dopaminergic innervating systems is involved in specific basal ganglia territories for different symptoms. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Effects of Whole Grain Wheat Bread on Visceral Fat Obesity in Japanese Subjects: A Randomized Double-Blind Study.

    PubMed

    Kikuchi, Yosuke; Nozaki, Satomi; Makita, Miki; Yokozuka, Shoji; Fukudome, Shin-Ichi; Yanagisawa, Takashi; Aoe, Seiichiro

    2018-04-18

    Metabolic syndrome is a risk factor for cardiovascular diseases and has become increasingly common in Japan. Epidemiological studies show inverse associations between intake of whole wheat grains and metabolic syndrome, but few dietary intervention trials have investigated the effect of whole wheat grain consumption. It was investigated whether a diet in which refined wheat bread (RW diet) was substituted by whole grain wheat bread (WW diet) would reduce visceral fat obesity in Japanese subjects. A randomized double-blind placebo-controlled intervention study was conducted in 50 Japanese subjects with body mass index (BMI) ≥ 23 kg/m 2 . Subjects were randomly assigned WW (WW group) or RW diets (RW group) for 12 weeks. Blood samples and computed tomography scans were obtained every 6th week. The WW group showed decrease (-4 cm 2 ) in visceral fat area (VFA) (p < 0.05), whereas the RW group showed no significant changes. These time-dependent changes were significantly different between the groups. WW diet led to significant and safe reductions in VFA in subjects with BMI ≥ 23 kg/m 2 . WW diet may contribute to preventing visceral fat obesity.

  4. Scatter correction for cone-beam computed tomography using self-adaptive scatter kernel superposition

    NASA Astrophysics Data System (ADS)

    Xie, Shi-Peng; Luo, Li-Min

    2012-06-01

    The authors propose a combined scatter reduction and correction method to improve image quality in cone beam computed tomography (CBCT). The scatter kernel superposition (SKS) method has been used occasionally in previous studies. However, this method differs in that a scatter detecting blocker (SDB) was used between the X-ray source and the tested object to model the self-adaptive scatter kernel. This study first evaluates the scatter kernel parameters using the SDB, and then isolates the scatter distribution based on the SKS. The quality of image can be improved by removing the scatter distribution. The results show that the method can effectively reduce the scatter artifacts, and increase the image quality. Our approach increases the image contrast and reduces the magnitude of cupping. The accuracy of the SKS technique can be significantly improved in our method by using a self-adaptive scatter kernel. This method is computationally efficient, easy to implement, and provides scatter correction using a single scan acquisition.

  5. EEG-tomographic studies with LORETA on vigilance differences between narcolepsy patients and controls and subsequent double-blind, placebo-controlled studies with modafinil.

    PubMed

    Saletu, M; Anderer, P; Saletu-Zyhlarz, G M; Mandl, M; Arnold, O; Zeitlhofer, J; Saletu, B

    2004-11-01

    The aim of the present study was to identify brain regions associated with vigilance in untreated and modafinil-treated narcoleptic patients by means of low-resolution brain electromagnetic tomography (LORETA). 16 drug-free narcoleptics and 16 normal controls were included in the baseline investigation. Subsequently patients participated in a double-blind, placebo-controlled crossover study receiving a three-week fixed titration of modafinil (200, 300, 400 mg) and placebo. Measurements comprised LORETA, the Multiple Sleep Latency Test (MSLT) and the Epworth Sleepiness Scale (ESS) obtained before and after three weeks' therapy. Statistical overall analysis by means of the omnibus significance test demonstrated significant inter-group differences in the resting (R-EEG), but not in the vigilance-controlled recordings (V-EEG). Subsequent univariate analysis revealed a decrease in alpha-2 and beta 1-3 power in prefrontal, temporal and parietal cortices, with the right hemisphere slightly more involved in this vigilance decrement. Modafinil 400 mg/d as compared with placebo induced changes opposite to the aforementioned baseline differences (key-lock principle) with a preponderance in the left hemisphere. This increase in vigilance resulted in an improvement in the MSLT and the ESS. LORETA provided evidence of a functional deterioration of the fronto-temporo-parietal network of the right-hemispheric vigilance system in narcolepsy and a therapeutic effect of modafinil on the left hemisphere, which is less affected by the disease.

  6. Earthquake hypocenter relocation using double difference method in East Java and surrounding areas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C, Aprilia Puspita; Meteorological, Climatological, and Geophysical Agency; Nugraha, Andri Dian, E-mail: nugraha@gf.itb.ac.id

    Determination of precise hypocenter location is very important in order to provide information about subsurface fault plane and for seismic hazard analysis. In this study, we have relocated hypocenter earthquakes in Eastern part of Java and surrounding areas from local earthquake data catalog compiled by Meteorological, Climatological, and Geophysical Agency of Indonesia (MCGA) in time period 2009-2012 by using the double-difference method. The results show that after relocation processes, there are significantly changes in position and orientation of earthquake hypocenter which is correlated with the geological setting in this region. We observed indication of double seismic zone at depths ofmore » 70-120 km within the subducting slab in south of eastern part of Java region. Our results will provide useful information for advance seismological studies and seismic hazard analysis in this study.« less

  7. Pull-in instability of paddle-type and double-sided NEMS sensors under the accelerating force

    NASA Astrophysics Data System (ADS)

    Keivani, M.; Khorsandi, J.; Mokhtari, J.; Kanani, A.; Abadian, N.; Abadyan, M.

    2016-02-01

    Paddle-type and double-sided nanostructures are potential for use as accelerometers in flying vehicles and aerospace applications. Herein the pull-in instability of the cantilever paddle-type and double-sided sensors in the Casimir regime are investigated under the acceleration. The D'Alembert principle is employed to transform the accelerating system into an equivalent static system by incorporating the accelerating force. Based on the couple stress theory (CST), the size-dependent constitutive equations of the sensors are derived. The governing nonlinear equations are solved by two approaches, i.e. modified variational iteration method and finite difference method. The influences of the Casimir force, geometrical parameters, acceleration and the size phenomenon on the instability performance have been demonstrated. The obtained results are beneficial to design and fabricate paddle-type and double-sided accelerometers.

  8. Imaging metallic samples using electrical capacitance tomography: forward modelling and reconstruction algorithms

    NASA Astrophysics Data System (ADS)

    Hosani, E. Al; Zhang, M.; Abascal, J. F. P. J.; Soleimani, M.

    2016-11-01

    Electrical capacitance tomography (ECT) is an imaging technology used to reconstruct the permittivity distribution within the sensing region. So far, ECT has been primarily used to image non-conductive media only, since if the conductivity of the imaged object is high, the capacitance measuring circuit will be almost shortened by the conductivity path and a clear image cannot be produced using the standard image reconstruction approaches. This paper tackles the problem of imaging metallic samples using conventional ECT systems by investigating the two main aspects of image reconstruction algorithms, namely the forward problem and the inverse problem. For the forward problem, two different methods to model the region of high conductivity in ECT is presented. On the other hand, for the inverse problem, three different algorithms to reconstruct the high contrast images are examined. The first two methods are the linear single step Tikhonov method and the iterative total variation regularization method, and use two sets of ECT data to reconstruct the image in time difference mode. The third method, namely the level set method, uses absolute ECT measurements and was developed using a metallic forward model. The results indicate that the applications of conventional ECT systems can be extended to metal samples using the suggested algorithms and forward model, especially using a level set algorithm to find the boundary of the metal.

  9. Teleseismic tomography for imaging Earth's upper mantle

    NASA Astrophysics Data System (ADS)

    Aktas, Kadircan

    Teleseismic tomography is an important imaging tool in earthquake seismology, used to characterize lithospheric structure beneath a region of interest. In this study I investigate three different tomographic techniques applied to real and synthetic teleseismic data, with the aim of imaging the velocity structure of the upper mantle. First, by applying well established traveltime tomographic techniques to teleseismic data from southern Ontario, I obtained high-resolution images of the upper mantle beneath the lower Great Lakes. Two salient features of the 3D models are: (1) a patchy, NNW-trending low-velocity region, and (2) a linear, NE-striking high-velocity anomaly. I interpret the high-velocity anomaly as a possible relict slab associated with ca. 1.25 Ga subduction, whereas the low-velocity anomaly is interpreted as a zone of alteration and metasomatism associated with the ascent of magmas that produced the Late Cretaceous Monteregian plutons. The next part of the thesis is concerned with adaptation of existing full-waveform tomographic techniques for application to teleseismic body-wave observations. The method used here is intended to be complementary to traveltime tomography, and to take advantage of efficient frequency-domain methodologies that have been developed for inverting large controlled-source datasets. Existing full-waveform acoustic modelling and inversion codes have been modified to handle plane waves impinging from the base of the lithospheric model at a known incidence angle. A processing protocol has been developed to prepare teleseismic observations for the inversion algorithm. To assess the validity of the acoustic approximation, the processing procedure and modelling-inversion algorithm were tested using synthetic seismograms computed using an elastic Kirchhoff integral method. These tests were performed to evaluate the ability of the frequency-domain full-waveform inversion algorithm to recover topographic variations of the Moho under a variety of realistic scenarios. Results show that frequency-domain full-waveform tomography is generally successful in recovering both sharp and discontinuous features. Thirdly, I developed a new method for creating an initial background velocity model for the inversion algorithm, which is sufficiently close to the true model so that convergence is likely to be achieved. I adapted a method named Deformable Layer Tomography (DLT), which adjusts interfaces between layers rather than velocities within cells. I applied this method to a simple model comprising a single uniform crustal layer and a constant-velocity mantle, separated by an irregular Moho interface. A series of tests was performed to evaluate the sensitivity of the DLT algorithm; the results show that my algorithm produces useful results within a realistic range of incident-wave obliquity, incidence angle and signal-to-noise level. Keywords. Teleseismic tomography, full waveform tomography, deformable layer tomography, lower Great Lakes, crust and upper mantle.

  10. Approximate solution of coupled cluster equations: application to the coupled cluster doubles method and non-covalent interacting systems.

    PubMed

    Smiga, Szymon; Fabiano, Eduardo

    2017-11-15

    We have developed a simplified coupled cluster (SCC) methodology, using the basic idea of scaled MP2 methods. The scheme has been applied to the coupled cluster double equations and implemented in three different non-iterative variants. This new method (especially the SCCD[3] variant, which utilizes a spin-resolved formalism) has been found to be very efficient and to yield an accurate approximation of the reference CCD results for both total and interaction energies of different atoms and molecules. Furthermore, we demonstrate that the equations determining the scaling coefficients for the SCCD[3] approach can generate non-empirical SCS-MP2 scaling coefficients which are in good agreement with previous theoretical investigations.

  11. The quadrant method measuring four points is as a reliable and accurate as the quadrant method in the evaluation after anatomical double-bundle ACL reconstruction.

    PubMed

    Mochizuki, Yuta; Kaneko, Takao; Kawahara, Keisuke; Toyoda, Shinya; Kono, Norihiko; Hada, Masaru; Ikegami, Hiroyasu; Musha, Yoshiro

    2017-11-20

    The quadrant method was described by Bernard et al. and it has been widely used for postoperative evaluation of anterior cruciate ligament (ACL) reconstruction. The purpose of this research is to further develop the quadrant method measuring four points, which we named four-point quadrant method, and to compare with the quadrant method. Three-dimensional computed tomography (3D-CT) analyses were performed in 25 patients who underwent double-bundle ACL reconstruction using the outside-in technique. The four points in this study's quadrant method were defined as point1-highest, point2-deepest, point3-lowest, and point4-shallowest, in femoral tunnel position. Value of depth and height in each point was measured. Antero-medial (AM) tunnel is (depth1, height2) and postero-lateral (PL) tunnel is (depth3, height4) in this four-point quadrant method. The 3D-CT images were evaluated independently by 2 orthopaedic surgeons. A second measurement was performed by both observers after a 4-week interval. Intra- and inter-observer reliability was calculated by means of intra-class correlation coefficient (ICC). Also, the accuracy of the method was evaluated against the quadrant method. Intra-observer reliability was almost perfect for both AM and PL tunnel (ICC > 0.81). Inter-observer reliability of AM tunnel was substantial (ICC > 0.61) and that of PL tunnel was almost perfect (ICC > 0.81). The AM tunnel position was 0.13% deep, 0.58% high and PL tunnel position was 0.01% shallow, 0.13% low compared to quadrant method. The four-point quadrant method was found to have high intra- and inter-observer reliability and accuracy. This method can evaluate the tunnel position regardless of the shape and morphology of the bone tunnel aperture for use of comparison and can provide measurement that can be compared with various reconstruction methods. The four-point quadrant method of this study is considered to have clinical relevance in that it is a detailed and accurate tool for evaluating femoral tunnel position after ACL reconstruction. Case series, Level IV.

  12. UTILIZATION OF FUNDUS AUTOFLUORESCENCE, SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY, AND ENHANCED DEPTH IMAGING IN THE CHARACTERIZATION OF BIETTI CRYSTALLINE DYSTROPHY IN DIFFERENT STAGES.

    PubMed

    Li, Qian; Li, Yang; Zhang, Xiaohui; Xu, Zhangxing; Zhu, Xiaoqing; Ma, Kai; She, Haicheng; Peng, Xiaoyan

    2015-10-01

    To characterize Bietti crystalline dystrophy (BCD) in different stages using multiple imaging modalities. Sixteen participants clinically diagnosed as BCD were included in the retrospective study and were categorized into 3 stages according to fundus photography. Eleven patients were genetically confirmed. Fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging features of BCD were analyzed. On fundus autofluorescence, the abnormal autofluorescence was shown to enlarge in area and decrease in intensity with stages. Using spectral domain optical coherence tomography, the abnormalities in Stage 1 were observed to localize in outer retinal layers, whereas in Stage 2 and Stage 3, more extensive retinal atrophy was seen. In enhanced depth imaging, the subfoveal choroidal layers were delineated clearly in Stage 1; in Stage 2, destructions were primarily found in the choriocapillaris with associated alterations in the outer vessels; Stage 3 BCD displayed severe choroidal thinning. Choroidal neovascularization and macular edema were exhibited with high incidence. IVS6-8del17bp/inGC of the CYP4V2 gene was the most common mutant allele. Noninvasive fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging may help to characterize the chorioretinal pathology of BCD at different degrees, and therefore, we propose staging of BCD depending on those methods. Physicians should be cautious of the vision-threatening complications of the disease.

  13. Grating Oriented Line-Wise Filtration (GOLF) for Dual-Energy X-ray CT

    NASA Astrophysics Data System (ADS)

    Xi, Yan; Cong, Wenxiang; Harrison, Daniel; Wang, Ge

    2017-12-01

    In medical X-ray Computed Tomography (CT), the use of two distinct X-ray source spectra (energies) allows dose-reduction and material discrimination relative to that achieved with only one source spectrum. Existing dual-energy CT methods include source kVp-switching, double-layer detection, dual-source gantry, and two-pass scanning. Each method suffers either from strong spectral correlation or patient-motion artifacts. To simultaneously address these problems, we propose to improve CT data acquisition with the Grating Oriented Line-wise Filtration (GOLF) method, a novel X-ray filter that is placed between the source and patient. GOLF uses a combination of absorption and filtering gratings that are moved relative to each other and in synchronization with the X-ray tube kVp-switching process and/or the detector view-sampling process. Simulation results show that GOLF can improve the spectral performance of kVp-switching to match that of dual-source CT while avoiding patient motion artifacts and dual imaging chains. Although significant flux is absorbed by this pre-patient filter, the proposed GOLF method is a novel path for cost-effectively extracting dual-energy or multi-energy data and reducing radiation dose with or without kVp switching.

  14. Grating Oriented Line-Wise Filtration (GOLF) for Dual-Energy X-ray CT

    PubMed Central

    Xi, Yan; Cong, Wenxiang; Harrison, Daniel

    2017-01-01

    In medical X-ray Computed Tomography (CT), the use of two distinct X-ray source spectra (energies) allows dose-reduction and material discrimination relative to that achieved with only one source spectrum. Existing dual-energy CT methods include source kVp-switching, double-layer detection, dual-source gantry, and two-pass scanning. Each method suffers either from strong spectral correlation or patient-motion artifacts. To simultaneously address these problems, we propose to improve CT data acquisition with the Grating Oriented Line-wise Filtration (GOLF) method, a novel X-ray filter that is placed between the source and patient. GOLF uses a combination of absorption and filtering gratings that are moved relative to each other and in synchronization with the X-ray tube kVp-switching process and/or the detector view-sampling process. Simulation results show that GOLF can improve the spectral performance of kVp-switching to match that of dual-source CT while avoiding patient motion artifacts and dual imaging chains. Although significant flux is absorbed by this pre-patient filter, the proposed GOLF method is a novel path for cost-effectively extracting dual-energy or multi-energy data and reducing radiation dose with or without kVp switching. PMID:29333113

  15. Molecular Contrast Optical Coherence Tomography: A Review¶

    PubMed Central

    Yang, Changhuei

    2005-01-01

    This article reviews the current state of research on the use of molecular contrast agents in optical coherence tomography (OCT) imaging techniques. After a brief discussion of the basic principle of OCT and the importance of incorporating molecular contrast agent usage into this imaging modality, we shall present an overview of the different molecular contrast OCT (MCOCT) methods that have been developed thus far. We will then discuss several important practical issues that define the possible range of contrast agent choice, the design criteria for engineered molecular contrast agent and the implementability of a given MCOCT method for clinical or biological applications. We will conclude by outlining a few areas of pursuit that deserve a greater degree of research and development. PMID:15588122

  16. Fast estimation of first-order scattering in a medical x-ray computed tomography scanner using a ray-tracing technique.

    PubMed

    Liu, Xin

    2014-01-01

    This study describes a deterministic method for simulating the first-order scattering in a medical computed tomography scanner. The method was developed based on a physics model of x-ray photon interactions with matter and a ray tracing technique. The results from simulated scattering were compared to the ones from an actual scattering measurement. Two phantoms with homogeneous and heterogeneous material distributions were used in the scattering simulation and measurement. It was found that the simulated scatter profile was in agreement with the measurement result, with an average difference of 25% or less. Finally, tomographic images with artifacts caused by scatter were corrected based on the simulated scatter profiles. The image quality improved significantly.

  17. 2-D Fused Image Reconstruction approach for Microwave Tomography: a theoretical assessment using FDTD Model

    PubMed Central

    Bindu, G.; Semenov, S.

    2013-01-01

    This paper describes an efficient two-dimensional fused image reconstruction approach for Microwave Tomography (MWT). Finite Difference Time Domain (FDTD) models were created for a viable MWT experimental system having the transceivers modelled using thin wire approximation with resistive voltage sources. Born Iterative and Distorted Born Iterative methods have been employed for image reconstruction with the extremity imaging being done using a differential imaging technique. The forward solver in the imaging algorithm employs the FDTD method of solving the time domain Maxwell’s equations with the regularisation parameter computed using a stochastic approach. The algorithm is tested with 10% noise inclusion and successful image reconstruction has been shown implying its robustness. PMID:24058889

  18. Evaluation of motion-correction methods for dual-gated cardiac positron emission tomography/computed tomography imaging.

    PubMed

    Klén, Riku; Noponen, Tommi; Koikkalainen, Juha; Lötjönen, Jyrki; Thielemans, Kris; Hoppela, Erika; Sipilä, Hannu; Teräs, Mika; Knuuti, Juhani

    2016-09-01

    Dual gating is a method of dividing the data of a cardiac PET scan into smaller bins according to the respiratory motion and the ECG of the patient. It reduces the undesirable motion artefacts in images, but produces several images for interpretation and decreases the quality of single images. By using motion-correction techniques, the motion artefacts in the dual-gated images can be corrected and the images can be combined into a single motion-free image with good statistics. The aim of the present study is to develop and evaluate motion-correction methods for cardiac PET studies. We have developed and compared two different methods: computed tomography (CT)/PET-based and CT-only methods. The methods were implemented and tested with a cardiac phantom and three patient datasets. In both methods, anatomical information of CT images is used to create models for the cardiac motion. In the patient study, the CT-only method reduced motion (measured as the centre of mass of the myocardium) on average 43%, increased the contrast-to-noise ratio on average 6.0% and reduced the target size on average 10%. Slightly better figures (51, 6.9 and 28%) were obtained with the CT/PET-based method. Even better results were obtained in the phantom study for both the CT-only method (57, 68 and 43%) and the CT/PET-based method (61, 74 and 52%). We conclude that using anatomical information of CT for motion correction of cardiac PET images, both respiratory and pulsatile motions can be corrected with good accuracy.

  19. LETTER TO THE EDITOR: Free-response operator characteristic models for visual search

    NASA Astrophysics Data System (ADS)

    Hutchinson, T. P.

    2007-05-01

    Computed tomography of diffraction enhanced imaging (DEI-CT) is a novel x-ray phase-contrast computed tomography which is applied to inspect weakly absorbing low-Z samples. Refraction-angle images which are extracted from a series of raw DEI images measured in different positions of the rocking curve of the analyser can be regarded as projections of DEI-CT. Based on them, the distribution of refractive index decrement in the sample can be reconstructed according to the principles of CT. How to combine extraction methods and reconstruction algorithms to obtain the most accurate reconstructed results is investigated in detail in this paper. Two kinds of comparison, the comparison of different extraction methods and the comparison between 'two-step' algorithms and the Hilbert filtered backprojection (HFBP) algorithm, draw the conclusion that the HFBP algorithm based on the maximum refraction-angle (MRA) method may be the best combination at present. Though all current extraction methods including the MRA method are approximate methods and cannot calculate very large refraction-angle values, the HFBP algorithm based on the MRA method is able to provide quite acceptable estimations of the distribution of refractive index decrement of the sample. The conclusion is proved by the experimental results at the Beijing Synchrotron Radiation Facility.

  20. A review of setup error in supine breast radiotherapy using cone-beam computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batumalai, Vikneswary, E-mail: Vikneswary.batumalai@sswahs.nsw.gov.au; Liverpool and Macarthur Cancer Therapy Centres, New South Wales; Ingham Institute of Applied Medical Research, Sydney, New South Wales

    2016-10-01

    Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registeringmore » CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.« less

  1. Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography.

    PubMed

    Trépout, Sylvain; Bastin, Philippe; Marco, Sergio

    2017-03-12

    This report describes a protocol for preparing thick biological specimens for further observation using a scanning transmission electron microscope. It also describes an imaging method for studying the 3D structure of thick biological specimens by scanning transmission electron tomography. The sample preparation protocol is based on conventional methods in which the sample is fixed using chemical agents, treated with a heavy atom salt contrasting agent, dehydrated in a series of ethanol baths, and embedded in resin. The specific imaging conditions for observing thick samples by scanning transmission electron microscopy are then described. Sections of the sample are observed using a through-focus method involving the collection of several images at various focal planes. This enables the recovery of in-focus information at various heights throughout the sample. This particular collection pattern is performed at each tilt angle during tomography data collection. A single image is then generated, merging the in-focus information from all the different focal planes. A classic tilt-series dataset is then generated. The advantage of the method is that the tilt-series alignment and reconstruction can be performed using standard tools. The collection of through-focal images allows the reconstruction of a 3D volume that contains all of the structural details of the sample in focus.

  2. Detection of mouse liver cancer via a parallel iterative shrinkage method in hybrid optical/microcomputed tomography imaging

    NASA Astrophysics Data System (ADS)

    Wu, Ping; Liu, Kai; Zhang, Qian; Xue, Zhenwen; Li, Yongbao; Ning, Nannan; Yang, Xin; Li, Xingde; Tian, Jie

    2012-12-01

    Liver cancer is one of the most common malignant tumors worldwide. In order to enable the noninvasive detection of small liver tumors in mice, we present a parallel iterative shrinkage (PIS) algorithm for dual-modality tomography. It takes advantage of microcomputed tomography and multiview bioluminescence imaging, providing anatomical structure and bioluminescence intensity information to reconstruct the size and location of tumors. By incorporating prior knowledge of signal sparsity, we associate some mathematical strategies including specific smooth convex approximation, an iterative shrinkage operator, and affine subspace with the PIS method, which guarantees the accuracy, efficiency, and reliability for three-dimensional reconstruction. Then an in vivo experiment on the bead-implanted mouse has been performed to validate the feasibility of this method. The findings indicate that a tiny lesion less than 3 mm in diameter can be localized with a position bias no more than 1 mm the computational efficiency is one to three orders of magnitude faster than the existing algorithms; this approach is robust to the different regularization parameters and the lp norms. Finally, we have applied this algorithm to another in vivo experiment on an HCCLM3 orthotopic xenograft mouse model, which suggests the PIS method holds the promise for practical applications of whole-body cancer detection.

  3. X-ray phase contrast tomography from whole organ down to single cells

    NASA Astrophysics Data System (ADS)

    Krenkel, Martin; Töpperwien, Mareike; Bartels, Matthias; Lingor, Paul; Schild, Detlev; Salditt, Tim

    2014-09-01

    We use propagation based hard x-ray phase contrast tomography to explore the three dimensional structure of neuronal tissues from the organ down to sub-cellular level, based on combinations of synchrotron radiation and laboratory sources. To this end a laboratory based microfocus tomography setup has been built in which the geometry was optimized for phase contrast imaging and tomography. By utilizing phase retrieval algorithms, quantitative reconstructions can be obtained that enable automatic renderings without edge artifacts. A high brightness liquid metal microfocus x-ray source in combination with a high resolution detector yielding a resolution down to 1.5 μm. To extend the method to nanoscale resolution we use a divergent x-ray waveguide beam geometry at the synchrotron. Thus, the magnification can be easily tuned by placing the sample at different defocus distances. Due to the small Fresnel numbers in this geometry the measured images are of holographic nature which poses a challenge in phase retrieval.

  4. Algorithms for bioluminescence tomography incorporating anatomical information and reconstruction of tissue optical properties

    PubMed Central

    Naser, Mohamed A.; Patterson, Michael S.

    2010-01-01

    Reconstruction algorithms are presented for a two-step solution of the bioluminescence tomography (BLT) problem. In the first step, a priori anatomical information provided by x-ray computed tomography or by other methods is used to solve the continuous wave (cw) diffuse optical tomography (DOT) problem. A Taylor series expansion approximates the light fluence rate dependence on the optical properties of each region where first and second order direct derivatives of the light fluence rate with respect to scattering and absorption coefficients are obtained and used for the reconstruction. In the second step, the reconstructed optical properties at different wavelengths are used to calculate the Green’s function of the system. Then an iterative minimization solution based on the L1 norm shrinks the permissible regions where the sources are allowed by selecting points with higher probability to contribute to the source distribution. This provides an efficient BLT reconstruction algorithm with the ability to determine relative source magnitudes and positions in the presence of noise. PMID:21258486

  5. 3D frequency-domain ultrasound waveform tomography breast imaging

    NASA Astrophysics Data System (ADS)

    Sandhu, Gursharan Yash; West, Erik; Li, Cuiping; Roy, Olivier; Duric, Neb

    2017-03-01

    Frequency-domain ultrasound waveform tomography is a promising method for the visualization and characterization of breast disease. It has previously been shown to accurately reconstruct the sound speed distributions of breasts of varying densities. The reconstructed images show detailed morphological and quantitative information that can help differentiate different types of breast disease including benign and malignant lesions. The attenuation properties of an ex vivo phantom have also been assessed. However, the reconstruction algorithms assumed a 2D geometry while the actual data acquisition process was not. Although clinically useful sound speed images can be reconstructed assuming this mismatched geometry, artifacts from the reconstruction process exist within the reconstructed images. This is especially true for registration across different modalities and when the 2D assumption is violated. For example, this happens when a patient's breast is rapidly sloping. It is also true for attenuation imaging where energy lost or gained out of the plane gets transformed into artifacts within the image space. In this paper, we will briefly review ultrasound waveform tomography techniques, give motivation for pursuing the 3D method, discuss the 3D reconstruction algorithm, present the results of 3D forward modeling, show the mismatch that is induced by the violation of 3D modeling via numerical simulations, and present a 3D inversion of a numerical phantom.

  6. Positron emission tomography response at the time of autologous stem cell transplantation predicts outcome of patients with relapsed and/or refractory Hodgkin’s lymphoma responding to prior salvage therapy

    PubMed Central

    Devillier, Raynier; Coso, Diane; Castagna, Luca; Brenot Rossi, Isabelle; Anastasia, Antonella; Chiti, Arturo; Ivanov, Vadim; Schiano, Jean Marc; Santoro, Armando; Chabannon, Christian; Balzarotti, Monica; Blaise, Didier; Bouabdallah, Reda

    2012-01-01

    Background High-dose chemotherapy followed by autologous stem cell transplantation is the standard treatment for relapsed and/or refractory Hodgkin’s lymphoma although half of patients relapse after transplantation. Predictive factors, such as relapse within 12 months, Ann-Arbor stage at relapse, and relapse in previously irradiated fields are classically used to identify patients with poor outcome. Recently, 18-fluorodeoxyglucose positron emission tomography has emerged as a new method for providing information to predict outcome. The aim of this study was to confirm the predictive value of positron emission tomography status after salvage therapy and to compare single versus tandem autologous stem cell transplantation in patients with relapsed and/or refractory Hodgkin’s lymphoma. Design and Methods We report a series of 111 consecutive patients with treatment-sensitive relapsed and/or treatment-refractory Hodgkin’s lymphoma who achieved complete (positron emission tomography-negative group) or partial remission (positron emission tomography-positive group) at positron emission tomography evaluation after salvage chemotherapy and who underwent single or tandem autologous stem cell transplantation. Results Five-year overall and progression-free survival rates were 81% and 64%, respectively. There were significant differences in 5-year progression-free survival (79% versus 23%; P<0.001) and 5-year overall survival (90% versus 55%, P=0.001) between the positron emission tomography-negative and -positive groups, respectively. A complete response, as determined by positron emission tomography evaluation, after salvage therapy predicted significantly better 5-year overall survival rates in both intermediate (91% versus 50%; P=0.029) and unfavorable (89% versus 58%; P=0.026) risk subgroup analyses. In the positron emission tomography-positive subgroup, tandem transplantation improved 5-year progression-free survival from 0% (in the single transplantation group) to 43% (P=0.034). Multivariate analysis showed that positron emission tomography status (hazard ratio: 5.26 [2.57–10.73]) and tandem transplantation (hazard ratio: 0.39 [0.19–0.78]) but not risk factors at relapse (hazard ratio: 1.77 [0.80–3.92]) significantly influenced progression-free survival, while only tomography status significantly influenced overall survival (hazard ratio: 4.03 [1.38–11.75]). Conclusions In patients with relapsed/refractory Hodgkin’s lymphoma responding to prior salvage therapy, positron emission tomography response at time of autologous stem cell transplantation favorably influences outcome and enables identification of patients requiring single or tandem transplantation. PMID:22271893

  7. Fluorescence diffuse tomography of small animals with DsRed2 fluorescent protein

    NASA Astrophysics Data System (ADS)

    Turchin, I. V.; Plehanov, V. I.; Orlova, A. G.; Kamenskiy, V. A.; Kleshnin, M. S.; Shirmanova, M. V.; Shakhova, N. M.; Balalaeva, I. V.; Savitskiy, A. P.

    2006-05-01

    Fluorescent compounds are used as markers to diagnose oncological diseases, to study molecular processes typical for carcinogenesis, and to investigate metastasis formation and tumor regress under the influence of therapeutics. Different types of tomography, such as continuous wave (CW), frequency-domain (FD), and time-domain (TD) tomography, allow fluorescence imaging of tumors located deep in human or animal tissue. In this work, preliminary results of the frequency domain fluorescent diffuse tomography (FDT) method in application to DsRed2 protein as a fluorescent agent are presented. For the first step of our experiments, we utilized low-frequency amplitude modulation (1 kHz) of second harmonic of Nd: YAG (532 nm). The transilluminative configuration was used in the setup. The results of post mortem experiments with capsules containing DsRed2 inserted inside the esophagus of a 3-day-old hairless rat to simulate tumor are shown. An algorithm of processing fluorescent images based on calculating the zero of maximum curvature has been applied to detect fluorescent inclusion boundaries in the image. This work demonstrates the potential capability of the FDT method for imaging deep fluorescent tumors in human tissue or animal models of human cancer. Improvement of the setup can be accomplished by using high-frequency modulation (using a 110-MHz acoustooptical modulator).

  8. Towards in vivo laser coagulation and concurrent optical coherence tomography through double-clad fiber devices

    NASA Astrophysics Data System (ADS)

    Beaudette, Kathy; Lo, William; Villiger, Martin; Shishkov, Milen; Godbout, Nicolas; Bouma, Brett E.; Boudoux, Caroline

    2016-03-01

    There is a strong clinical need for an optical coherence tomography (OCT) system capable of delivering concurrent coagulation light enabling image-guided dynamic laser marking for targeted collection of biopsies, as opposed to a random sampling, to reduce false-negative findings. Here, we present a system based on double-clad fiber (DCF) capable of delivering pulsed laser light through the inner cladding while performing OCT through the core. A previously clinically validated commercial OCT system (NVisionVLE, Ninepoint Medical) was adapted to enable in vivo esophageal image-guided dynamic laser marking. An optimized DCF coupler was implemented into the system to couple both modalities into the DCF. A DCF-based rotary joint was used to couple light to the spinning DCF-based catheter for helical scanning. DCF-based OCT catheters, providing a beam waist diameter of 62μm at a working distance of 9.3mm, for use with a 17-mm diameter balloon sheath, were used for ex vivo imaging of a swine esophagus. Imaging results using the DCF-based clinical system show an image quality comparable with a conventional system with minimal crosstalk-induced artifacts. To further optimize DCF catheter optical design in order to achieve single-pulse marking, a Zemax model of the DCF output and its validation are presented.

  9. Effect of Two Different Methods of Initiating Atomoxetine on the Adverse Event Profile of Atomoxetine

    ERIC Educational Resources Information Center

    Greenhill, Laurence L.; Newcorn, Jeffrey H.; Gao, Haitao; Feldman, Peter D.

    2007-01-01

    Objective: To compare the effects of two different methods for initiating atomoxetine in terms of the incidence of early adverse events. Method: Data on atomoxetine treatment-emergent adverse events in youths, ages 6 to 18 years, were analyzed from five randomized, double-blind, placebo-controlled, acute-phase studies. Two studies involve…

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reusch, L. M., E-mail: lmmcguire@wisc.edu; Den Hartog, D. J.; Goetz, J.

    The two-color soft x-ray (SXR) tomography diagnostic on the Madison Symmetric Torus is capable of making electron temperature measurements via the double-filter technique; however, there has been a 15% systematic discrepancy between the SXR double-filter (SXR{sub DF}) temperature and Thomson scattering (TS) temperature. Here we discuss calibration of the Be filters used in the SXR{sub DF} measurement using empirical measurements of the transmission function versus energy at the BESSY II electron storage ring, electron microprobe analysis of filter contaminants, and measurement of the effective density. The calibration does not account for the TS and SXR{sub DF} discrepancy, and evidence frommore » experiments indicates that this discrepancy is due to physics missing from the SXR{sub DF} analysis rather than instrumentation effects.« less

  11. Influence of off-great-circle propagation of Rayleigh waves on event-based surface wave tomography in Northeast China

    NASA Astrophysics Data System (ADS)

    Chen, Haopeng; Ni, Sidao; Chu, Risheng; Chong, Jiajun; Liu, Zhikun; Zhu, Liangbao

    2018-05-01

    Surface waves are generally assumed to propagate along great-circle paths in most surface-wave tomography. However, when lateral heterogeneity is strong, off-great-circle propagation may occur and deteriorate surface wave tomography results based on the great-circle assumption. In this study, we used teleseismic waveforms recorded by the NECESSArray in Northeast China to study off-great-circle propagation of Rayleigh waves using the beamforming method and evaluated the influence of off-great-circle propagation on event-based surface wave tomography. The results show that arrival angle anomalies generally increase with decreasing period. The arrival angle anomalies at 60 and 50 s periods are smaller than that at 40 and 30 s periods, which indicates that the off-great-circle propagation is relatively weak for longer periods. At 30 s period, the arrival angle anomalies are relatively larger and some of the measurements can exceed 20°, which represents a strong off-great-circle propagation effect. In some areas, the arrival angle anomalies of adjacent events differ significantly, which may be attributed to multipathing propagation of surface waves. To evaluate the influence of off-great-circle propagation on event-based surface wave tomography, we used measured arrival angle anomalies to correct two-station phase velocity measurements, and performed azimuthal anisotropy tomography using dispersion datasets with and without the arrival angle correction. At longer periods, such as 60 s, the influence of off-great-circle propagation on surface wave tomography is weak even though the corrected model has better data fit than the uncorrected model. However, the influence of off-great-circle propagation is non-negligible at short periods. The tomography results at 30 s period show that the differences in phase velocity, the strength of anisotropy and the fast direction can be as large as 1.5 per cent, 1.0 per cent and 30°, respectively. Furthermore, the corrected phase velocity is systematically lower than that without correction. This study illustrates the necessity of studying the off-great-circle propagation of surface waves to improve the accuracy of event-based surface wave tomography, especially for shorter periods.

  12. Log file-based patient dose calculations of double-arc VMAT for head-and-neck radiotherapy.

    PubMed

    Katsuta, Yoshiyuki; Kadoya, Noriyuki; Fujita, Yukio; Shimizu, Eiji; Majima, Kazuhiro; Matsushita, Haruo; Takeda, Ken; Jingu, Keiichi

    2018-04-01

    The log file-based method cannot display dosimetric changes due to linac component miscalibration because of the insensitivity of log files to linac component miscalibration. The purpose of this study was to supply dosimetric changes in log file-based patient dose calculations for double-arc volumetric-modulated arc therapy (VMAT) in head-and-neck cases. Fifteen head-and-neck cases participated in this study. For each case, treatment planning system (TPS) doses were produced by double-arc and single-arc VMAT. Miscalibration-simulated log files were generated by inducing a leaf miscalibration of ±0.5 mm into the log files that were acquired during VMAT irradiation. Subsequently, patient doses were estimated using the miscalibration-simulated log files. For double-arc VMAT, regarding planning target volume (PTV), the change from TPS dose to miscalibration-simulated log file dose in D mean was 0.9 Gy and that for tumor control probability was 1.4%. As for organ-at-risks (OARs), the change in D mean was <0.7 Gy and normal tissue complication probability was <1.8%. A comparison between double-arc and single-arc VMAT for PTV showed statistically significant differences in the changes evaluated by D mean and radiobiological metrics (P < 0.01), even though the magnitude of these differences was small. Similarly, for OARs, the magnitude of these changes was found to be small. Using the log file-based method for PTV and OARs, the log file-based method estimate of patient dose using the double-arc VMAT has accuracy comparable to that obtained using the single-arc VMAT. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Therapy-related longitudinal brain perfusion changes in patients with chronic pelvic pain syndrome.

    PubMed

    Weisstanner, Christian; Mordasini, Livio; Thalmann, George N; Verma, Rajeev K; Rummel, Christian; Federspiel, Andrea; Kessler, Thomas M; Wiest, Roland

    2017-08-03

    The imaging method most frequently employed to identify brain areas involved in neuronal processing of nociception and brain pain perception is blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI). Arterial spin labelling (ASL), in contrast, offers advantages when slow varying changes in brain function are investigated. Chronic pelvic pain syndrome (CPPS) is a disorder of, mostly, young males that leads to altered pain perceptions in structures related to the pelvis. We aimed to investigate the potential of ASL to monitor longitudinal cranial blood flow (CBF) changes in patients with CPPS. In a randomised, placebo-controlled, double-blind single centre trial, we investigated treatment effects in CPPS after 12 weeks in patients that underwent sono-electro-magnetic therapy vs placebo. We investigated changes of CBF related to treatment outcome using pseudo-continuous arterial spin labelling (pCASL)-MRI. We observed CBF downregulation in the prefrontal cortex and anterior cingulate cortex and upregulation in the dorsolateral prefrontal cortex in responders. Nonresponders presented with CBF upregulation in the hippocampus. In patients with a history of CPPS of less than 12 months, there were significant correlations between longitudinal CBF changes and the Chronic Prostatitis Symptom Index pain subscore within the joint clusters anterior cingulate cortex and left anterior prefrontal cortex in responders, and the right hippocampus in nonresponders. We demonstrated therapy-related and stimulus-free longitudinal CBF changes in core areas of the pain matrix using ASL. ASL may act as a complementary noninvasive method to functional MRI and single-photon emission computed tomography / positron emission tomography, especially in the longitudinal assessment of pain response in clinical trials.

  14. Evaluating the efficiency of spectral resolution of univariate methods manipulating ratio spectra and comparing to multivariate methods: An application to ternary mixture in common cold preparation

    NASA Astrophysics Data System (ADS)

    Moustafa, Azza Aziz; Salem, Hesham; Hegazy, Maha; Ali, Omnia

    2015-02-01

    Simple, accurate, and selective methods have been developed and validated for simultaneous determination of a ternary mixture of Chlorpheniramine maleate (CPM), Pseudoephedrine HCl (PSE) and Ibuprofen (IBF), in tablet dosage form. Four univariate methods manipulating ratio spectra were applied, method A is the double divisor-ratio difference spectrophotometric method (DD-RD). Method B is double divisor-derivative ratio spectrophotometric method (DD-RD). Method C is derivative ratio spectrum-zero crossing method (DRZC), while method D is mean centering of ratio spectra (MCR). Two multivariate methods were also developed and validated, methods E and F are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods have the advantage of simultaneous determination of the mentioned drugs without prior separation steps. They were successfully applied to laboratory-prepared mixtures and to commercial pharmaceutical preparation without any interference from additives. The proposed methods were validated according to the ICH guidelines. The obtained results were statistically compared with the official methods where no significant difference was observed regarding both accuracy and precision.

  15. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    PubMed

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust quantitative image reconstruction and biomarker analysis, there may be an expanded role for SPECT/CT imaging in renal masses and other pathologic conditions.

  16. Efficient option valuation of single and double barrier options

    NASA Astrophysics Data System (ADS)

    Kabaivanov, Stanimir; Milev, Mariyan; Koleva-Petkova, Dessislava; Vladev, Veselin

    2017-12-01

    In this paper we present an implementation of pricing algorithm for single and double barrier options using Mellin transformation with Maximum Entropy Inversion and its suitability for real-world applications. A detailed analysis of the applied algorithm is accompanied by implementation in C++ that is then compared to existing solutions in terms of efficiency and computational power. We then compare the applied method with existing closed-form solutions and well known methods of pricing barrier options that are based on finite differences.

  17. Influence of the Redundant Verification and the Non-Redundant Verification on the Hydraulic Tomography

    NASA Astrophysics Data System (ADS)

    Wei, T. B.; Chen, Y. L.; Lin, H. R.; Huang, S. Y.; Yeh, T. C. J.; Wen, J. C.

    2016-12-01

    In the groundwater study, it estimated the heterogeneous spatial distribution of hydraulic Properties, there were many scholars use to hydraulic tomography (HT) from field site pumping tests to estimate inverse of heterogeneous spatial distribution of hydraulic Properties, to prove the most of most field site aquifer was heterogeneous hydrogeological parameters spatial distribution field. Many scholars had proposed a method of hydraulic tomography to estimate heterogeneous spatial distribution of hydraulic Properties of aquifer, the Huang et al. [2011] was used the non-redundant verification analysis of pumping wells changed, observation wells fixed on the inverse and the forward, to reflect the feasibility of the heterogeneous spatial distribution of hydraulic Properties of field site aquifer of the non-redundant verification analysis on steady-state model.From post literature, finding only in steady state, non-redundant verification analysis of pumping well changed location and observation wells fixed location for inverse and forward. But the studies had not yet pumping wells fixed or changed location, and observation wells fixed location for redundant verification or observation wells change location for non-redundant verification of the various combinations may to explore of influences of hydraulic tomography method. In this study, it carried out redundant verification method and non-redundant verification method for forward to influences of hydraulic tomography method in transient. And it discuss above mentioned in NYUST campus sites the actual case, to prove the effectiveness of hydraulic tomography methods, and confirmed the feasibility on inverse and forward analysis from analysis results.Keywords: Hydraulic Tomography, Redundant Verification, Heterogeneous, Inverse, Forward

  18. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dugas, Alexandre; Therasse, Eric; Kauffmann, Claude

    2012-08-15

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: Dmax, as measuredmore » on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001-0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662-0.780) and single-plane MPR images (0.772-0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.« less

  19. A Simultaneous and Continuous Excitation Method for High-Speed Electrical Impedance Tomography with Reduced Transients and Noise Sensitivity

    PubMed Central

    Mylvaganam, Saba

    2018-01-01

    This paper presents a concept for soft field tomographic scan of all the projections of electromagnetic waves emanating from an array of electrodes. Instead of the sequential excitation of all pairs of electrodes in the list of all projections, the new method present here consists of a single and continuous excitation. This excitation signal is the linear combination of the excitation signals in the projection set at different AC frequencies. The response to a given projection is discriminated by selecting the corresponding AC frequency component in the signal spectra of the digitally demodulated signals. The main advantage of this method is the suppression of transients after each projection, which is particularly problematic in electrical impedance tomography due to contact impedance phenomena and skin effect. The second benefit over the sequential scan method is the increased number of samples for each measurement for reduced noise sensitivity with digital demodulation. The third benefit is the increased temporal resolution in high-speed applications. The main drawback is the increased number of signal sources required (one per electrode). This paper focuses on electrical impedance tomography, based on earlier work by the authors. An experimental proof-of-concept using a simple 4-electrodes electrical impedance tomographic system is presented using simulations and laboratory data. The method presented here may be extended to other modalities (ultrasonic, microwave, optical, etc.). PMID:29597327

  20. Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morozov, A N; Turchin, I V

    2013-12-31

    The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resultingmore » field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)« less

  1. Linearized image reconstruction method for ultrasound modulated electrical impedance tomography based on power density distribution

    NASA Astrophysics Data System (ADS)

    Song, Xizi; Xu, Yanbin; Dong, Feng

    2017-04-01

    Electrical resistance tomography (ERT) is a promising measurement technique with important industrial and clinical applications. However, with limited effective measurements, it suffers from poor spatial resolution due to the ill-posedness of the inverse problem. Recently, there has been an increasing research interest in hybrid imaging techniques, utilizing couplings of physical modalities, because these techniques obtain much more effective measurement information and promise high resolution. Ultrasound modulated electrical impedance tomography (UMEIT) is one of the newly developed hybrid imaging techniques, which combines electric and acoustic modalities. A linearized image reconstruction method based on power density is proposed for UMEIT. The interior data, power density distribution, is adopted to reconstruct the conductivity distribution with the proposed image reconstruction method. At the same time, relating the power density change to the change in conductivity, the Jacobian matrix is employed to make the nonlinear problem into a linear one. The analytic formulation of this Jacobian matrix is derived and its effectiveness is also verified. In addition, different excitation patterns are tested and analyzed, and opposite excitation provides the best performance with the proposed method. Also, multiple power density distributions are combined to implement image reconstruction. Finally, image reconstruction is implemented with the linear back-projection (LBP) algorithm. Compared with ERT, with the proposed image reconstruction method, UMEIT can produce reconstructed images with higher quality and better quantitative evaluation results.

  2. A sensitivity analysis on seismic tomography data with respect to CO2 saturation of a CO2 geological sequestration field

    NASA Astrophysics Data System (ADS)

    Park, Chanho; Nguyen, Phung K. T.; Nam, Myung Jin; Kim, Jongwook

    2013-04-01

    Monitoring CO2 migration and storage in geological formations is important not only for the stability of geological sequestration of CO2 but also for efficient management of CO2 injection. Especially, geophysical methods can make in situ observation of CO2 to assess the potential leakage of CO2 and to improve reservoir description as well to monitor development of geologic discontinuity (i.e., fault, crack, joint, etc.). Geophysical monitoring can be based on wireline logging or surface surveys for well-scale monitoring (high resolution and nallow area of investigation) or basin-scale monitoring (low resolution and wide area of investigation). In the meantime, crosswell tomography can make reservoir-scale monitoring to bridge the resolution gap between well logs and surface measurements. This study focuses on reservoir-scale monitoring based on crosswell seismic tomography aiming describe details of reservoir structure and monitoring migration of reservoir fluid (water and CO2). For the monitoring, we first make a sensitivity analysis on crosswell seismic tomography data with respect to CO2 saturation. For the sensitivity analysis, Rock Physics Models (RPMs) are constructed by calculating the values of density and P and S-wave velocities of a virtual CO2 injection reservoir. Since the seismic velocity of the reservoir accordingly changes as CO2 saturation changes when the CO2 saturation is less than about 20%, while when the CO2 saturation is larger than 20%, the seismic velocity is insensitive to the change, sensitivity analysis is mainly made when CO2 saturation is less than 20%. For precise simulation of seismic tomography responses for constructed RPMs, we developed a time-domain 2D elastic modeling based on finite difference method with a staggered grid employing a boundary condition of a convolutional perfectly matched layer. We further make comparison between sensitivities of seismic tomography and surface measurements for RPMs to analysis resolution difference between them. Moreover, assuming a similar reservoir situation to the CO2 storage site in Nagaoka, Japan, we generate time-lapse tomographic data sets for the corresponding CO2 injection process, and make a preliminary interpretation of the data sets.

  3. Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

    PubMed

    Brodén, Cyrus; Olivecrona, Henrik; Maguire, Gerald Q; Noz, Marilyn E; Zeleznik, Michael P; Sköldenberg, Olof

    2016-01-01

    Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty. Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated. Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv. Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting.

  4. Migration without migraines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lines, L.; Burton, A.; Lu, H.X.

    Accurate velocity models are a necessity for reliable migration results. Velocity analysis generally involves the use of methods such as normal moveout analysis (NMO), seismic traveltime tomography, or iterative prestack migration. These techniques can be effective, and each has its own advantage or disadvantage. Conventional NMO methods are relatively inexpensive but basically require simplifying assumptions about geology. Tomography is a more general method but requires traveltime interpretation of prestack data. Iterative prestack depth migration is very general but is computationally expensive. In some cases, there is the opportunity to estimate vertical velocities by use of well information. The well informationmore » can be used to optimize poststack migrations, thereby eliminating some of the time and expense of iterative prestack migration. The optimized poststack migration procedure defined here computes the velocity model which minimizes the depth differences between seismic images and formation depths at the well by using a least squares inversion method. The optimization methods described in this paper will hopefully produce ``migrations without migraines.``« less

  5. X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging

    NASA Astrophysics Data System (ADS)

    Vågberg, William; Larsson, Daniel H.; Li, Mei; Arner, Anders; Hertz, Hans M.

    2015-11-01

    Imaging of muscular structure with cellular or subcellular detail in whole-body animal models is of key importance for understanding muscular disease and assessing interventions. Classical histological methods for high-resolution imaging methods require excision, fixation and staining. Here we show that the three-dimensional muscular structure of unstained whole zebrafish can be imaged with sub-5 μm detail with X-ray phase-contrast tomography. Our method relies on a laboratory propagation-based phase-contrast system tailored for detection of low-contrast 4-6 μm subcellular myofibrils. The method is demonstrated on 20 days post fertilization zebrafish larvae and comparative histology confirms that we resolve individual myofibrils in the whole-body animal. X-ray imaging of healthy zebrafish show the expected structured muscle pattern while specimen with a dystrophin deficiency (sapje) displays an unstructured pattern, typical of Duchenne muscular dystrophy. The method opens up for whole-body imaging with sub-cellular detail also of other types of soft tissue and in different animal models.

  6. Thickness dependence of the levitation performance of double-layer high-temperature superconductor bulks above a magnetic rail

    NASA Astrophysics Data System (ADS)

    Sun, R. X.; Zheng, J.; Liao, X. L.; Che, T.; Gou, Y. F.; He, D. B.; Deng, Z. G.

    2014-10-01

    A double-layer high-temperature superconductor (HTSC) arrangement was proposed and proved to be able to bring improvements to both levitation force and guidance force compared with present single-layer HTSC arrangement. To fully exploit the applied magnetic field by a magnetic rail, the thickness dependence of a double-layer HTSC arrangement on the levitation performance was further investigated in the paper. In this study, the lower-layer bulk was polished step by step to different thicknesses, and the upper-layer bulk with constant thickness was directly superimposed on the lower-layer one. The levitation force and the force relaxation of the double-layer HTSC arrangement were measured above a Halbach magnetic rail. Experimental result shows that a bigger levitation force and a less levitation force decay could be achieved by optimizing the thickness of the lower-layer bulk HTSC. This thickness optimization method could be applied together with former reported double-layer HTSC arrangement method with aligned growth sector boundaries pattern. This series of study on the optimized combination method do bring a significant improvement on the levitation performance of present HTS maglev systems.

  7. Quantification of cellular autofluorescence of human skin using multiphoton tomography and fluorescence lifetime imaging in two spectral detection channels

    PubMed Central

    Patalay, Rakesh; Talbot, Clifford; Alexandrov, Yuriy; Munro, Ian; Neil, Mark A. A.; König, Karsten; French, Paul M. W.; Chu, Anthony; Stamp, Gordon W.; Dunsby, Chris

    2011-01-01

    We explore the diagnostic potential of imaging endogenous fluorophores using two photon microscopy and fluorescence lifetime imaging (FLIM) in human skin with two spectral detection channels. Freshly excised benign dysplastic nevi (DN) and malignant nodular Basal Cell Carcinomas (nBCCs) were excited at 760 nm. The resulting fluorescence signal was binned manually on a cell by cell basis. This improved the reliability of fitting using a double exponential decay model and allowed the fluorescence signatures from different cell populations within the tissue to be identified and studied. We also performed a direct comparison between different diagnostic groups. A statistically significant difference between the median mean fluorescence lifetime of 2.79 ns versus 2.52 ns (blue channel, 300-500 nm) and 2.08 ns versus 1.33 ns (green channel, 500-640 nm) was found between nBCCs and DN respectively, using the Mann-Whitney U test (p < 0.01). Further differences in the distribution of fluorescence lifetime parameters and inter-patient variability are also discussed. PMID:22162820

  8. Radiomics-based differentiation of lung disease models generated by polluted air based on X-ray computed tomography data.

    PubMed

    Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos

    2016-02-11

    Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann-Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas.

  9. Inter- and intraobserver reliability of the vertebral, local and segmental kyphosis in 120 traumatic lumbar and thoracic burst fractures: evaluation in lateral X-rays and sagittal computed tomographies

    PubMed Central

    Brunner, Alexander; Gühring, Markus; Schmälzle, Traude; Weise, Kuno; Badke, Andreas

    2009-01-01

    Evaluation of the kyphosis angle in thoracic and lumbar burst fractures is often used to indicate surgical procedures. The kyphosis angle could be measured as vertebral, segmental and local kyphosis according to the method of Cobb. The vertebral, segmental and local kyphosis according to the method of Cobb were measured at 120 lateral X-rays and sagittal computed tomographies of 60 thoracic and 60 lumbar burst fractures by 3 independent observers on 2 separate occasions. Osteoporotic fractures were excluded. The intra- and interobserver reliability of these angles in X-ray and computed tomogram, using the intra class correlation coefficient (ICC) were evaluated. Highest reproducibility showed the segmental kyphosis followed by the vertebral kyphosis. For thoracic fractures segmental kyphosis shows in X-ray “excellent” inter- and intraobserver reliabilities (ICC 0.826, 0.802) and for lumbar fractures “good” to “excellent” inter- and intraobserver reliabilities (ICC = 0.790, 0.803). In computed tomography, the segmental kyphosis showed “excellent” inter- and intraobserver reliabilities (ICC = 0.824, 0.801) for thoracic and “excellent” inter- and intraobserver reliabilities (ICC = 0.874, 0.835) for the lumbar fractures. Regarding both diagnostic work ups (X-ray and computed tomography), significant differences were evaluated in interobserver reliabilities for vertebral kyphosis measured in lumbar fracture X-rays (p = 0.035) and interobserver reliabilities for local kyphosis, measured in thoracic fracture X-rays (p = 0.010). Regarding both fracture localizations (thoracic and lumbar fractures), significant differences could only be evaluated in interobserver reliabilities for the local kyphosis measured in computed tomographies (p = 0.045) and in intraobserver reliabilities for the vertebral kyphosis measured in X-rays (p = 0.024). “Good” to “excellent” inter- and intraobserver reliabilities for vertebral, segmental and local kyphosis in X-ray make these angles to a helpful tool, indicating surgical procedures. For the practical use in lateral X-ray, we emphasize the determination of the segmental kyphosis, because of the highest reproducibility of this angle. “Good” to “excellent” inter- and intraobserver reliabilities for these three angles could also be evaluated in computed tomographies. Therefore, also in computed tomography, the use of these three angles seems to be generally possible. For a direct correlation of the results in lateral X-ray and in computed tomography, further studies should be needed. PMID:19953277

  10. Pretreatment of patients requiring oral contrast abdominal computed tomography with antiemetics: a randomized controlled trial of efficacy.

    PubMed

    Garra, Gregory; Singer, Adam J; Bamber, Danny; Chohan, Jasmine; Troxell, Regina; Thode, Henry C

    2009-04-01

    Ingestion of diatrizoate meglumine before abdominal computed tomography (CT) is time consuming. We hypothesized that pretreatment with metoclopramide or ondansetron would result in faster ingestion of diatrizoate meglumine than placebo. The study was a double-blind, randomized controlled trial on adults requiring oral contrast abdominal CT. Patients were randomized to placebo, metoclopramide 10 mg, or ondansetron 4 mg intravenously 15 minutes before ingesting 2 L of diatrizoate meglumine. The primary outcome was time to complete diatrizoate meglumine ingestion. Secondary outcome measures included volume of diatrizoate meglumine ingested, 100-mm visual analog scale for nausea at 15-minute intervals, time to CT, vomiting, and use of rescue antiemetics. The study was powered to detect a 60-minute difference in diatrizoate meglumine ingestion time between saline and medication groups. One hundred six patients were randomized; placebo (36), metoclopramide (35), and ondansetron (35). Groups were similar in baseline characteristics. Median (interquartile range) times for diatrizoate meglumine ingestion were placebo 109 minutes (82 to 135 minutes); metoclopramide 105 minutes (75 to 135 minutes); and ondansetron 110 minutes (79 to 140 minutes) (P=.67). Vomiting was less frequent with metoclopramide (3%) than placebo (18%) or ondansetron (9%) (P=.11). The visual analog scale for nausea at each point was not significantly different between groups (P=.11). The need for rescue antiemetics was lowest for metoclopramide (3%) compared with placebo (27%) and ondansetron (12%) (P=.02). Pretreatment with ondansetron or metoclopramide does not reduce oral contrast solution ingestion time.

  11. Progress toward scalable tomography of quantum maps using twirling-based methods and information hierarchies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez, Cecilia C.; Theoretische Physik, Universitaet des Saarlandes, D-66041 Saarbruecken; Departament de Fisica, Universitat Autonoma de Barcelona, E-08193 Bellaterra

    2010-06-15

    We present in a unified manner the existing methods for scalable partial quantum process tomography. We focus on two main approaches: the one presented in Bendersky et al. [Phys. Rev. Lett. 100, 190403 (2008)] and the ones described, respectively, in Emerson et al. [Science 317, 1893 (2007)] and Lopez et al. [Phys. Rev. A 79, 042328 (2009)], which can be combined together. The methods share an essential feature: They are based on the idea that the tomography of a quantum map can be efficiently performed by studying certain properties of a twirling of such a map. From this perspective, inmore » this paper we present extensions, improvements, and comparative analyses of the scalable methods for partial quantum process tomography. We also clarify the significance of the extracted information, and we introduce interesting and useful properties of the {chi}-matrix representation of quantum maps that can be used to establish a clearer path toward achieving full tomography of quantum processes in a scalable way.« less

  12. Interference experiment with asymmetric double slit by using 1.2-MV field emission transmission electron microscope.

    PubMed

    Harada, Ken; Akashi, Tetsuya; Niitsu, Kodai; Shimada, Keiko; Ono, Yoshimasa A; Shindo, Daisuke; Shinada, Hiroyuki; Mori, Shigeo

    2018-01-17

    Advanced electron microscopy technologies have made it possible to perform precise double-slit interference experiments. We used a 1.2-MV field emission electron microscope providing coherent electron waves and a direct detection camera system enabling single-electron detections at a sub-second exposure time. We developed a method to perform the interference experiment by using an asymmetric double-slit fabricated by a focused ion beam instrument and by operating the microscope under a "pre-Fraunhofer" condition, different from the Fraunhofer condition of conventional double-slit experiments. Here, pre-Fraunhofer condition means that each single-slit observation was performed under the Fraunhofer condition, while the double-slit observations were performed under the Fresnel condition. The interference experiments with each single slit and with the asymmetric double slit were carried out under two different electron dose conditions: high-dose for calculation of electron probability distribution and low-dose for each single electron distribution. Finally, we exemplified the distribution of single electrons by color-coding according to the above three types of experiments as a composite image.

  13. Swept source optical coherence tomography for in vivo growth monitoring of capsicum annuum seeds treated with different NaCl concentrations

    NASA Astrophysics Data System (ADS)

    Ravichandran, Naresh Kumar; Wijesinghe, Ruchire Eranga; Lee, Seung-Yeol; Shirazi, Muhammad Faizan; Park, Kibeom; Jung, Hee-Young; Jeon, Mansik; Kim, Jeehyun

    2017-04-01

    In this study, Optical coherence tomography (OCT) is demonstrated as a plausible optical tool for in vivo detection of plant seeds and its morphological changes during growth. The experiment was carried out on Capsicum annuum seeds that were treated with different molar concentrations of NaCl to investigate the most optimal concentration for the seed growth. The monitoring process was carried out for 9 consecutive days. The in vivo 2D OCT images of the treated seeds were obtained and compared with seeds that were grown with sterile distilled water. The obtained results confirm the feasibility of using OCT for the proposed application. Normalized A-scan analysis method is utilized for supporting the concluded results.

  14. Electron tomography reveals the fibril structure and lipid interactions in amyloid deposits

    PubMed Central

    Kollmer, Marius; Meinhardt, Katrin; Haupt, Christian; Liberta, Falk; Wulff, Melanie; Linder, Julia; Handl, Lisa; Heinrich, Liesa; Loos, Cornelia; Schmidt, Matthias; Syrovets, Tatiana; Simmet, Thomas; Westermark, Per; Westermark, Gunilla T.; Horn, Uwe; Schmidt, Volker; Walther, Paul; Fändrich, Marcus

    2016-01-01

    Electron tomography is an increasingly powerful method to study the detailed architecture of macromolecular complexes or cellular structures. Applied to amyloid deposits formed in a cell culture model of systemic amyloid A amyloidosis, we could determine the structural morphology of the fibrils directly in the deposit. The deposited fibrils are arranged in different networks, and depending on the relative fibril orientation, we can distinguish between fibril meshworks, fibril bundles, and amyloid stars. These networks are frequently infiltrated by vesicular lipid inclusions that may originate from the death of the amyloid-forming cells. Our data support the role of nonfibril components for constructing fibril deposits and provide structural views of different types of lipid–fibril interactions. PMID:27140609

  15. Applications of the JARS method to study levee sites in southern Texas and southern New Mexico

    USGS Publications Warehouse

    Ivanov, J.; Miller, R.D.; Xia, J.; Dunbar, J.B.

    2007-01-01

    We apply the joint analysis of refractions with surface waves (JARS) method to several sites and compare its results to traditional refraction-tomography methods in efforts of finding a more realistic solution to the inverse refraction-traveltime problem. The JARS method uses a reference model, derived from surface-wave shear-wave velocity estimates, as a constraint. In all of the cases JARS estimates appear more realistic than those from the conventional refraction-tomography methods. As a result, we consider, the JARS algorithm as the preferred method for finding solutions to the inverse refraction-tomography problems. ?? 2007 Society of Exploration Geophysicists.

  16. Statistical methods for meta-analyses including information from studies without any events-add nothing to nothing and succeed nevertheless.

    PubMed

    Kuss, O

    2015-03-30

    Meta-analyses with rare events, especially those that include studies with no event in one ('single-zero') or even both ('double-zero') treatment arms, are still a statistical challenge. In the case of double-zero studies, researchers in general delete these studies or use continuity corrections to avoid them. A number of arguments against both options has been given, and statistical methods that use the information from double-zero studies without using continuity corrections have been proposed. In this paper, we collect them and compare them by simulation. This simulation study tries to mirror real-life situations as completely as possible by deriving true underlying parameters from empirical data on actually performed meta-analyses. It is shown that for each of the commonly encountered effect estimators valid statistical methods are available that use the information from double-zero studies without using continuity corrections. Interestingly, all of them are truly random effects models, and so also the current standard method for very sparse data as recommended from the Cochrane collaboration, the Yusuf-Peto odds ratio, can be improved on. For actual analysis, we recommend to use beta-binomial regression methods to arrive at summary estimates for the odds ratio, the relative risk, or the risk difference. Methods that ignore information from double-zero studies or use continuity corrections should no longer be used. We illustrate the situation with an example where the original analysis ignores 35 double-zero studies, and a superior analysis discovers a clinically relevant advantage of off-pump surgery in coronary artery bypass grafting. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Gas-water two-phase flow characterization with Electrical Resistance Tomography and Multivariate Multiscale Entropy analysis.

    PubMed

    Tan, Chao; Zhao, Jia; Dong, Feng

    2015-03-01

    Flow behavior characterization is important to understand gas-liquid two-phase flow mechanics and further establish its description model. An Electrical Resistance Tomography (ERT) provides information regarding flow conditions at different directions where the sensing electrodes implemented. We extracted the multivariate sample entropy (MSampEn) by treating ERT data as a multivariate time series. The dynamic experimental results indicate that the MSampEn is sensitive to complexity change of flow patterns including bubbly flow, stratified flow, plug flow and slug flow. MSampEn can characterize the flow behavior at different direction of two-phase flow, and reveal the transition between flow patterns when flow velocity changes. The proposed method is effective to analyze two-phase flow pattern transition by incorporating information of different scales and different spatial directions. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Concealed nuclear material identification via combined fast-neutron/γ-ray computed tomography (FNGCT): a Monte Carlo study

    NASA Astrophysics Data System (ADS)

    Licata, M.; Joyce, M. J.

    2018-02-01

    The potential of a combined and simultaneous fast-neutron/γ-ray computed tomography technique using Monte Carlo simulations is described. This technique is applied on the basis of a hypothetical tomography system comprising an isotopic radiation source (americium-beryllium) and a number (13) of organic scintillation detectors for the production and detection of both fast neutrons and γ rays, respectively. Via a combination of γ-ray and fast neutron tomography the potential is demonstrated to discern nuclear materials, such as compounds comprising plutonium and uranium, from substances that are used widely for neutron moderation and shielding. This discrimination is achieved on the basis of the difference in the attenuation characteristics of these substances. Discrimination of a variety of nuclear material compounds from shielding/moderating substances (the latter comprising lead or polyethylene for example) is shown to be challenging when using either γ-ray or neutron tomography in isolation of one another. Much-improved contrast is obtained for a combination of these tomographic modalities. This method has potential applications for in-situ, non-destructive assessments in nuclear security, safeguards, waste management and related requirements in the nuclear industry.

  19. Endoscopic high-resolution auto fluorescence imaging and optical coherence tomography of airways in vivo (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pahlevaninezhad, Hamid; Lee, Anthony; Hohert, Geoffrey; Schwartz, Carley; Shaipanich, Tawimas; Ritchie, Alexander J.; Zhang, Wei; MacAulay, Calum E.; Lam, Stephen; Lane, Pierre M.

    2016-03-01

    In this work, we present multimodal imaging of peripheral airways in vivo using an endoscopic imaging system capable of co-registered optical coherence tomography and autofluorescence imaging (OCT-AFI). This system employs a 0.9 mm diameter double-clad fiber optic-based catheter for endoscopic imaging of small peripheral airways. Optical coherence tomography (OCT) can visualize detailed airway morphology in the lung periphery and autofluorescence imaging (AFI) can visualize fluorescent tissue components such as collagen and elastin, improving the detection of airway lesions. Results from in vivo imaging of 40 patients indicate that OCT and AFI offer complementary information that may increase the ability to identify pulmonary nodules in the lung periphery and improve the safety of biopsy collection by identifying large blood vessels. AFI can rapidly visualize in vivo vascular networks using fast scanning parameters resulting in vascular-sensitive imaging with less breathing/cardiac motion artifacts compared to Doppler OCT imaging. By providing complementary information about structure and function of tissue, OCT-AFI may improve site selection during biopsy collection in the lung periphery.

  20. Assessment of anterior shoulder instability by CT arthrography.

    PubMed

    Yang, S O; Cho, K J; Kim, M J; Ro, I W

    1987-09-01

    Computed tomography (CT) immediately after double-contrast shoulder arthrography was taken in twenty-two young male patients with anterior shoulder instability including recurrent dislocation and subluxation. This recently developed technique called CT arthrography can provide significant information about patients with glenohumeral instability which is difficult to obtain by conventional arthrography. Information about glenoid labrum pathology is useful for proper management of the shoulder with instability. Lesions identified in this study include anterior labral defects (attenuation, tear, displacement), anterior capsular distension and/or detachment, Hill-Sachs lesion, anterior glenoid rim compression fracture, and fracture of scapula. This article describes the method used in CT arthrography of the glenohumeral joint, reviews the normal cross-sectional anatomy, and emphasizes the importance of the application of CT arthrography in the shoulder disorder with instability. CT arthrography of the glenohumeral joint is easy to perform, is accurate, and has lower radiation dose than arthrotomography.

  1. Multifocal visual evoked potentials for early glaucoma detection.

    PubMed

    Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W

    2012-07-01

    To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.

  2. Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears.

    PubMed

    Aydin, Nuri; Kocaoglu, Baris; Guven, Osman

    2010-07-01

    Double-row rotator cuff repair leads to superior cuff integrity and clinical results compared with single-row repair. The study enrolled 68 patients with a full-thickness rotator cuff tear who were divided into 2 groups of 34 patients according to repair technique. The patients were followed-up for at least 2 years. The results were evaluated by Constant score. Despite the biomechanical studies and cadaver studies that proved the superiority of double-row fixation over single-row fixation, our clinical results show no difference in functional outcome between the two methods. It is evident that double-row repair is more technically demanding, expensive, and time-consuming than single-row repair, without providing a significant improvement in clinical results. Comparison between groups did not show significant differences. At the final follow-up, the Constant score was 82.2 in the single-row group and 78.8 in the double-row group. Functional outcome was improved in both groups after surgery, but the difference between the 2 groups was not significant. At long-term follow-up, arthroscopic rotator cuff repair with the double-row technique showed no significant difference in clinical outcome compared with single-row repair in small to medium tears. 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  3. Beamlines of the Biomedical Imaging and Therapy Facility at the Canadian Light Source - Part 2

    NASA Astrophysics Data System (ADS)

    Wysokinski, T. W.; Chapman, D.; Adams, G.; Renier, M.; Suortti, P.; Thomlinson, W.

    2013-03-01

    The BioMedical Imaging and Therapy (BMIT) facility provides a world class facility with unique synchrotron-specific imaging and therapy capabilities. This paper describes Insertion Device (ID) beamline 05ID-2 with the beam terminated in the first experimental hutch: POE-2. The experimental methods available in POE-2 include: Microbeam Radiation Therapy (MRT), Synchrotron Stereotactic Radiation Therapy (SSRT) and absorption imaging (projection and Computed Tomography (CT)). The source for the ID beamline is a multi-pole superconductive 4.3 T wiggler, which can generate ~30 kW of radiative power and deliver dose as high as 3000 Gy/s required for MRT program. The optics in POE-1 hutch prepares either monochromatic or filtered white beam that is used in POE-2. The Double Crystal (DC), bent Laue monochromator will prepare a beam over 10 cm wide at sample point, while spanning an energy range appropriate for imaging studies of animals (20-100+ keV). The experimental hutch will have a flexible positioning system that can handle subjects up to 120 kg. Several different cameras will be available with resolutions ranging from 4 μm to 150 μm. The latest update on the status of 05B1-1 bending magnet (BM) beamline, described in Part 1 [1], is also included.

  4. Open Tibial Inlay PCL Reconstruction: Surgical Technique and Clinical Outcomes.

    PubMed

    Vellios, Evan E; Jones, Kristofer J; McAllister, David R

    2018-06-01

    To review the current literature on clinical outcomes following open tibial inlay posterior cruciate ligament (PCL) reconstruction and provide the reader with a detailed description of the author's preferred surgical technique. Despite earlier biomechanical studies which demonstrated superiority of the PCL inlay technique when compared to transtibial techniques, recent longitudinal cohort studies have shown no significant differences in clinical or functional outcomes at 10-year follow-up. Furthermore, no significant clinical differences have been shown between graft types used and/or single- versus double-bundle reconstruction methods. The optimal treatment for the PCL-deficient knee remains unclear. Open tibial inlay PCL reconstruction is safe, reproducible, and avoids the "killer turn" that may potentially lead to graft weakening and failure seen in transtibial reconstruction methods. No significant differences in subjective outcomes or clinical laxity have been shown between single-bundle versus double-bundle reconstruction methods.

  5. Alternative methods for determining shrinkage in restorative resin composites.

    PubMed

    de Melo Monteiro, Gabriela Queiroz; Montes, Marcos Antonio Japiassú Resende; Rolim, Tiago Vieira; de Oliveira Mota, Cláudia Cristina Brainer; de Barros Correia Kyotoku, Bernardo; Gomes, Anderson Stevens Leônidas; de Freitas, Anderson Zanardi

    2011-08-01

    The purpose of this study was to evaluate polymerization shrinkage of resin composites using a coordinate measuring machine, optical coherence tomography and a more widely known method, such as Archimedes Principle. Two null hypothesis were tested: (1) there are no differences between the materials tested; (2) there are no differences between the methods used for polymerization shrinkage measurements. Polymerization shrinkage of seven resin-based dental composites (Filtek Z250™, Filtek Z350™, Filtek P90™/3M ESPE, Esthet-X™, TPH Spectrum™/Dentsply 4 Seasons™, Tetric Ceram™/Ivoclar-Vivadent) was measured. For coordinate measuring machine measurements, composites were applied to a cylindrical Teflon mold (7 mm × 2 mm), polymerized and removed from the mold. The difference between the volume of the mold and the volume of the specimen was calculated as a percentage. Optical coherence tomography was also used for linear shrinkage evaluations. The thickness of the specimens was measured before and after photoactivation. Polymerization shrinkage was also measured using Archimedes Principle of buoyancy (n=5). Statistical analysis of the data was performed with ANOVA and the Games-Howell test. The results show that polymerization shrinkage values vary with the method used. Despite numerical differences the ranking of the resins was very similar with Filtek P90 presenting the lowest shrinkage values. Because of the variations in the results, reported values could only be used to compare materials within the same method. However, it is possible rank composites for polymerization shrinkage and to relate these data from different test methods. Independently of the method used, reduced polymerization shrinkage was found for silorane resin-based composite. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Generating multi-double-scroll attractors via nonautonomous approach.

    PubMed

    Hong, Qinghui; Xie, Qingguo; Shen, Yi; Wang, Xiaoping

    2016-08-01

    It is a common phenomenon that multi-scroll attractors are realized by introducing the various nonlinear functions with multiple breakpoints in double scroll chaotic systems. Differently, we present a nonautonomous approach for generating multi-double-scroll attractors (MDSA) without changing the original nonlinear functions. By using the multi-level-logic pulse excitation technique in double scroll chaotic systems, MDSA can be generated. A Chua's circuit, a Jerk circuit, and a modified Lorenz system are given as designed example and the Matlab simulation results are presented. Furthermore, the corresponding realization circuits are designed. The Pspice results are in agreement with numerical simulation results, which verify the availability and feasibility of this method.

  7. Influence of a Double-Lumen Extension Tube on Drug Delivery: Examples of Isosorbide Dinitrate and Diazepam

    PubMed Central

    Maiguy-Foinard, Aurélie; Blanchemain, Nicolas; Barthélémy, Christine; Odou, Pascal

    2016-01-01

    Purpose Plastic materials such as polyurethane (PUR), polyethylene (PE), polypropylene (PP) and polyvinyl chloride (PVC) are widely used in double-lumen extension tubing. The purposes of our study were to 1) compare in vitro drug delivery through the double extension tubes available on the market 2) assess the plastic properties of PUR in infusion devices and their impact on drug delivery. Methods The study compared eight double-lumen extension tubes in PUR, co-extruded (PE/PVC) plastic and plasticised PVC from different manufacturers. Isosorbide dinitrate and diazepam were used as model compounds to evaluate their sorption on the internal surface of the infusion device. Control experiments were performed using norepinephrine known not to absorb to plastics. Drug concentrations delivered at the egress of extension tubes were determined over time by an analytical spectrophotometric UV-Vis method. The main characteristics of plastics were also determined. Results Significant differences in the sorption phenomenon were observed among the eight double-lumen extension tubes and between pairs of extension tubes. Mean concentrations of isosorbide dinitrate delivered at the egress of double-lumen extension tubes after a 150-minute infusion (mean values ± standard deviation in percentage of the initial concentrations in the prepared syringes) ranged between 80.53 ± 1.66 (one of the PUR tubes) and 92.84 ± 2.73 (PE/PVC tube). The same parameters measured during diazepam infusion ranged between 48.58 ± 2.88 (one of the PUR tubes) and 85.06 ± 3.94 (PE/PVC tube). The double-lumen extension tubes in PUR were either thermosetting (resin) or thermoplastic according to reference. Conclusions Clinicians must be aware of potential drug interactions with extension tube materials and so must consider their nature as well as the sterilisation method used before selecting an infusion device. PMID:27153224

  8. Monitoring the gingival regeneration after aesthetic surgery with optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Fernandes, Luana O.; Graça, Natalia D. R. L.; Melo, Luciana S. A.; Silva, Claudio H. V.; Gomes, Anderson S. L.

    2016-02-01

    The aim of this study was to use the Optical Coherence Tomography (OCT) technique working in spectral domain (Swept Source OCT at 1325 nm, Thorlabs, New Jersey, USA) to monitor the tissue repair in patients undergoing periodontal plastic surgery. The evaluations were done over a period of 60 days. It was observed that 15 days after periodontal surgery the gum was still in different healing process as compared to the observation after 60 days. Thus it is clear that, despite some technical limitations, the OCT is an efficient method in the evaluation of regeneration gingival.

  9. Uniqueness and reconstruction in magnetic resonance-electrical impedance tomography (MR-EIT).

    PubMed

    Ider, Y Ziya; Onart, Serkan; Lionheart, William R B

    2003-05-01

    Magnetic resonance-electrical impedance tomography (MR-EIT) was first proposed in 1992. Since then various reconstruction algorithms have been suggested and applied. These algorithms use peripheral voltage measurements and internal current density measurements in different combinations. In this study the problem of MR-EIT is treated as a hyperbolic system of first-order partial differential equations, and three numerical methods are proposed for its solution. This approach is not utilized in any of the algorithms proposed earlier. The numerical solution methods are integration along equipotential surfaces (method of characteristics), integration on a Cartesian grid, and inversion of a system matrix derived by a finite difference formulation. It is shown that if some uniqueness conditions are satisfied, then using at least two injected current patterns, resistivity can be reconstructed apart from a multiplicative constant. This constant can then be identified using a single voltage measurement. The methods proposed are direct, non-iterative, and valid and feasible for 3D reconstructions. They can also be used to easily obtain slice and field-of-view images from a 3D object. 2D simulations are made to illustrate the performance of the algorithms.

  10. Monte Carlo-based fluorescence molecular tomography reconstruction method accelerated by a cluster of graphic processing units.

    PubMed

    Quan, Guotao; Gong, Hui; Deng, Yong; Fu, Jianwei; Luo, Qingming

    2011-02-01

    High-speed fluorescence molecular tomography (FMT) reconstruction for 3-D heterogeneous media is still one of the most challenging problems in diffusive optical fluorescence imaging. In this paper, we propose a fast FMT reconstruction method that is based on Monte Carlo (MC) simulation and accelerated by a cluster of graphics processing units (GPUs). Based on the Message Passing Interface standard, we modified the MC code for fast FMT reconstruction, and different Green's functions representing the flux distribution in media are calculated simultaneously by different GPUs in the cluster. A load-balancing method was also developed to increase the computational efficiency. By applying the Fréchet derivative, a Jacobian matrix is formed to reconstruct the distribution of the fluorochromes using the calculated Green's functions. Phantom experiments have shown that only 10 min are required to get reconstruction results with a cluster of 6 GPUs, rather than 6 h with a cluster of multiple dual opteron CPU nodes. Because of the advantages of high accuracy and suitability for 3-D heterogeneity media with refractive-index-unmatched boundaries from the MC simulation, the GPU cluster-accelerated method provides a reliable approach to high-speed reconstruction for FMT imaging.

  11. Optimized doppler optical coherence tomography for choroidal capillary vasculature imaging

    NASA Astrophysics Data System (ADS)

    Liu, Gangjun; Qi, Wenjuan; Yu, Lingfeng; Chen, Zhongping

    2011-03-01

    In this paper, we analyzed the retinal and choroidal blood vasculature in the posterior segment of the human eye with optimized color Doppler and Doppler variance optical coherence tomography. Depth-resolved structure, color Doppler and Doppler variance images were compared. Blood vessels down to capillary level were able to be obtained with the optimized optical coherence color Doppler and Doppler variance method. For in-vivo imaging of human eyes, bulkmotion induced bulk phase must be identified and removed before using color Doppler method. It was found that the Doppler variance method is not sensitive to bulk motion and the method can be used without removing the bulk phase. A novel, simple and fast segmentation algorithm to indentify retinal pigment epithelium (RPE) was proposed and used to segment the retinal and choroidal layer. The algorithm was based on the detected OCT signal intensity difference between different layers. A spectrometer-based Fourier domain OCT system with a central wavelength of 890 nm and bandwidth of 150nm was used in this study. The 3-dimensional imaging volume contained 120 sequential two dimensional images with 2048 A-lines per image. The total imaging time was 12 seconds and the imaging area was 5x5 mm2.

  12. Method for imaging with low frequency electromagnetic fields

    DOEpatents

    Lee, Ki H.; Xie, Gan Q.

    1994-01-01

    A method for imaging with low frequency electromagnetic fields, and for interpreting the electromagnetic data using ray tomography, in order to determine the earth conductivity with high accuracy and resolution. The imaging method includes the steps of placing one or more transmitters, at various positions in a plurality of transmitter holes, and placing a plurality of receivers in a plurality of receiver holes. The transmitters generate electromagnetic signals which diffuse through a medium, such as earth, toward the receivers. The measured diffusion field data H is then transformed into wavefield data U. The traveltimes corresponding to the wavefield data U, are then obtained, by charting the wavefield data U, using a different regularization parameter .alpha. for each transform. The desired property of the medium, such as conductivity, is then derived from the velocity, which in turn is constructed from the wavefield data U using ray tomography.

  13. Method for imaging with low frequency electromagnetic fields

    DOEpatents

    Lee, K.H.; Xie, G.Q.

    1994-12-13

    A method is described for imaging with low frequency electromagnetic fields, and for interpreting the electromagnetic data using ray tomography, in order to determine the earth conductivity with high accuracy and resolution. The imaging method includes the steps of placing one or more transmitters, at various positions in a plurality of transmitter holes, and placing a plurality of receivers in a plurality of receiver holes. The transmitters generate electromagnetic signals which diffuse through a medium, such as earth, toward the receivers. The measured diffusion field data H is then transformed into wavefield data U. The travel times corresponding to the wavefield data U, are then obtained, by charting the wavefield data U, using a different regularization parameter [alpha] for each transform. The desired property of the medium, such as conductivity, is then derived from the velocity, which in turn is constructed from the wavefield data U using ray tomography. 13 figures.

  14. Pancreatic and Gastric Heterotopia with Associated Submucosal Lipoma Presenting as a 7-cm Obstructive Tumor of the Ileum: Resection with Double Balloon Enteroscopy.

    PubMed

    Jiang, Kun; Stephen, F Otis; Jeong, Daniel; Pimiento, Jose M

    2015-01-01

    Pancreatic and gastric heterotopias are rare clinical entities which have been identified throughout the entire length of the gastrointestinal tract. Combined gastric and pancreatic heterotopias, although unusual, have been described in the duodenum and jejunum, and in other structures, including Meckel's diverticulum and the ampulla of Vater. We report a novel case of pancreatic and gastric heterotopia with an associated submucosal lipoma in a 38-year-old female with a recent history of rectal cancer and chronic crampy abdominal pain. On computed tomography, a 7-cm luminal polypoid mass extending into the distal ileum was discovered. The mass was successfully resected using retrograde double balloon enteroscopy. We believe this is the first report of all three histological entities co-existing in an obstructive ileal lesion in an adult. It highlights endoscopic resection trough double enteroscopy as a safe alternative to more invasive surgical approaches for this type of lesion.

  15. VESUVIO-the double difference inverse geometry spectrometer at ISIS

    NASA Astrophysics Data System (ADS)

    Mayers, J.; Tomkinson, J.; Abdul-Redah, T.; Stirling, W. G.; Andreani, C.; Senesi, R.; Nardone, M.; Colognesi, D.; Degiorgi, E.

    2004-07-01

    The VESUVIO spectrometer at the ISIS pulsed neutron source performs inelastic neutron scattering at high-energy and wave vector transfers, employing gold and uranium resonant foils. A factor of two improvement in the instrumental resolution has been achieved by making use of the double filter difference method. Experimental results are presented for measurements on polycrystalline Pb, which indicate that accurate measurements of single-particle momentum distribution n(p) in quantum fluids are now possible at eV energy transfers.

  16. Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients.

    PubMed

    Herweh, Christian; Ringleb, Peter A; Rauch, Geraldine; Gerry, Steven; Behrens, Lars; Möhlenbruch, Markus; Gottorf, Rebecca; Richter, Daniel; Schieber, Simon; Nagel, Simon

    2016-06-01

    The Alberta Stroke Program Early CT score (ASPECTS) is an established 10-point quantitative topographic computed tomography scan score to assess early ischemic changes. We compared the performance of the e-ASPECTS software with those of stroke physicians at different professional levels. The baseline computed tomography scans of acute stroke patients, in whom computed tomography and diffusion-weighted imaging scans were obtained less than two hours apart, were retrospectively scored by e-ASPECTS as well as by three stroke experts and three neurology trainees blinded to any clinical information. The ground truth was defined as the ASPECTS on diffusion-weighted imaging scored by another two non-blinded independent experts on consensus basis. Sensitivity and specificity in an ASPECTS region-based and an ASPECTS score-based analysis as well as receiver-operating characteristic curves, Bland-Altman plots with mean score error, and Matthews correlation coefficients were calculated. Comparisons were made between the human scorers and e-ASPECTS with diffusion-weighted imaging being the ground truth. Two methods for clustered data were used to estimate sensitivity and specificity in the region-based analysis. In total, 34 patients were included and 680 (34 × 20) ASPECTS regions were scored. Mean time from onset to computed tomography was 172 ± 135 min and mean time difference between computed tomographyand magnetic resonance imaging was 41 ± 31 min. The region-based sensitivity (46.46% [CI: 30.8;62.1]) of e-ASPECTS was better than three trainees and one expert (p ≤ 0.01) and not statistically different from another two experts. Specificity (94.15% [CI: 91.7;96.6]) was lower than one expert and one trainee (p < 0.01) and not statistically different to the other four physicians. e-ASPECTS had the best Matthews correlation coefficient of 0.44 (experts: 0.38 ± 0.08 and trainees: 0.19 ± 0.05) and the lowest mean score error of 0.56 (experts: 1.44 ± 1.79 and trainees: 1.97 ± 2.12). e-ASPECTS showed a similar performance to that of stroke experts in the assessment of brain computed tomographys of acute ischemic stroke patients with the Alberta Stroke Program Early CT score method. © 2016 World Stroke Organization.

  17. Development of the algorithm of measurement data and tomographic section reconstruction results processing for evaluating the respiratory activity of the lungs using the multi-angle electric impedance tomography

    NASA Astrophysics Data System (ADS)

    Aleksanyan, Grayr; Shcherbakov, Ivan; Kucher, Artem; Sulyz, Andrew

    2018-04-01

    Continuous monitoring of the patient's breathing by the method of multi-angle electric impedance tomography allows to obtain images of conduction change in the chest cavity during the monitoring. Direct analysis of images is difficult due to the large amount of information and low resolution images obtained by multi-angle electrical impedance tomography. This work presents a method for obtaining a graph of respiratory activity of the lungs based on the results of continuous lung monitoring using the multi-angle electrical impedance tomography method. The method makes it possible to obtain a graph of the respiratory activity of the left and right lungs separately, as well as a summary graph, to which it is possible to apply methods of processing the results of spirography.

  18. Comparison of glomerular filtration rate determined by use of single-slice dynamic computed tomography and scintigraphy in cats.

    PubMed

    Schmidt, David M; Scrivani, Peter V; Dykes, Nathan L; Goldstein, Richard M; Erb, Hollis N; Reeves, Anthony P

    2012-04-01

    To compare estimation of glomerular filtration rate determined via conventional methods (ie, scintigraphy and plasma clearance of technetium Tc 99m pentetate) and dynamic single-slice computed tomography (CT). 8 healthy adult cats. Scintigraphy, plasma clearance testing, and dynamic CT were performed on each cat on the same day; order of examinations was randomized. Separate observers performed GFR calculations for scintigraphy, plasma clearance testing, or dynamic CT. Methods were compared via Bland-Altman plots and considered interchangeable and acceptable when the 95% limits of agreement (mean difference between methods ± 1.96 SD of the differences) were ≤ 0.7 mL/min/kg. Global GFR differed < 0.7 mL/min/kg in 5 of 8 cats when comparing plasma clearance testing and dynamic CT; the limits of agreement were 1.4 and -1.7 mL/min/kg. The mean ± SD difference was -0.2 ± 0.8 mL/min/kg, and the maximum difference was 1.6 mL/min/kg. The mean ± SD difference (absolute value) for percentage filtration by individual kidneys was 2.4 ± 10.5% when comparing scintigraphy and dynamic CT; the maximum difference was 20%, and the limits of agreement were 18% and 23% (absolute value). GFR estimation via dynamic CT exceeded the definition for acceptable clinical use, compared with results for conventional methods, which was likely attributable to sample size and preventable technical complications. Because 5 of 8 cats had comparable values between methods, further investigation of dynamic CT in a larger sample population with a wide range of GFR values should be performed.

  19. [Quantitative analysis method based on fractal theory for medical imaging of normal brain development in infants].

    PubMed

    Li, Heheng; Luo, Liangping; Huang, Li

    2011-02-01

    The present paper is aimed to study the fractal spectrum of the cerebral computerized tomography in 158 normal infants of different age groups, based on the calculation of chaotic theory. The distribution range of neonatal period was 1.88-1.90 (mean = 1.8913 +/- 0.0064); It reached a stable condition at the level of 1.89-1.90 during 1-12 months old (mean = 1.8927 +/- 0.0045); The normal range of 1-2 years old infants was 1.86-1.90 (mean = 1.8863 +/- 4 0.0085); It kept the invariance of the quantitative value among 1.88-1.91(mean = 1.8958 +/- 0.0083) during 2-3 years of age. ANOVA indicated there's no significant difference between boys and girls (F = 0.243, P > 0.05), but the difference of age groups was significant (F = 8.947, P < 0.001). The fractal dimension of cerebral computerized tomography in normal infants computed by box methods was maintained at an efficient stability from 1.86 to 1.91. It indicated that there exit some attractor modes in pediatric brain development.

  20. Improving material identification by combining x-ray and neutron tomography

    NASA Astrophysics Data System (ADS)

    LaManna, Jacob M.; Hussey, Daniel S.; Baltic, Eli; Jacobson, David L.

    2017-09-01

    X-rays and neutrons provide complementary non-destructive probes for the analysis of structure and chemical composition of materials. Contrast differences between the modes arise due to the differences in interaction with matter. Due to the high sensitivity to hydrogen, neutrons excel at separating liquid water or hydrogenous phases from the underlying structure while X-rays resolve the solid structure. Many samples of interest, such as fluid flow in porous materials or curing concrete, are stochastic or slowly changing with time which makes analysis of sequential imaging with X-rays and neutrons difficult as the sample may change between scans. To alleviate this issue, NIST has developed a system for simultaneous X-ray and neutron tomography by orienting a 90 keVpeak micro-focus X-ray tube orthogonally to a thermal neutron beam. This system allows for non-destructive, multimodal tomography of dynamic or stochastic samples while penetrating through sample environment equipment such as pressure and flow vessels. Current efforts are underway to develop methods for 2D histogram based segmentation of reconstructed volumes. By leveraging the contrast differences between X-rays and neutrons, greater histogram peak separation can occur in 2D vs 1D enabling improved material identification.

  1. Towards pH-sensitive imaging of small animals with photon-counting difference diffuse fluorescence tomography

    NASA Astrophysics Data System (ADS)

    Li, Jiao; Wang, Xin; Yi, Xi; Zhang, Limin; Zhou, Zhongxing; Zhao, Huijuan; Gao, Feng

    2012-09-01

    The importance of cellular pH has been shown clearly in the study of cell activity, pathological feature, and drug metabolism. Monitoring pH changes of living cells and imaging the regions with abnormal pH-values, in vivo, could provide invaluable physiological and pathological information for the research of the cell biology, pharmacokinetics, diagnostics, and therapeutics of certain diseases such as cancer. Naturally, pH-sensitive fluorescence imaging of bulk tissues has been attracting great attentions from the realm of near infrared diffuse fluorescence tomography (DFT). Herein, the feasibility of quantifying pH-induced fluorescence changes in turbid medium is investigated using a continuous-wave difference-DFT technique that is based on the specifically designed computed tomography-analogous photon counting system and the Born normalized difference image reconstruction scheme. We have validated the methodology using two-dimensional imaging experiments on a small-animal-sized phantom, embedding an inclusion with varying pH-values. The results show that the proposed approach can accurately localize the target with a quantitative resolution to pH-sensitive variation of the fluorescent yield, and might provide a promising alternative method of pH-sensitive fluorescence imaging in addition to the fluorescence-lifetime imaging.

  2. Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images

    PubMed Central

    Antony, Bhavna; Abràmoff, Michael D.; Tang, Li; Ramdas, Wishal D.; Vingerling, Johannes R.; Jansonius, Nomdo M.; Lee, Kyungmoo; Kwon, Young H.; Sonka, Milan; Garvin, Mona K.

    2011-01-01

    The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y axes. In this paper, we propose a novel technique that uses thin-plate splines in two stages to estimate and correct the distinct axial artifacts in SD-OCT images. The method was quantitatively validated using nine pairs of OCT scans obtained with orthogonal fast-scanning axes, where a segmented surface was compared after both datasets had been corrected. The mean unsigned difference computed between the locations of this artifact-corrected surface after the single-spline and dual-spline correction was 23.36 ± 4.04 μm and 5.94 ± 1.09 μm, respectively, and showed a significant difference (p < 0.001 from two-tailed paired t-test). The method was also validated using depth maps constructed from stereo fundus photographs of the optic nerve head, which were compared to the flattened top surface from the OCT datasets. Significant differences (p < 0.001) were noted between the artifact-corrected datasets and the original datasets, where the mean unsigned differences computed over 30 optic-nerve-head-centered scans (in normalized units) were 0.134 ± 0.035 and 0.302 ± 0.134, respectively. PMID:21833377

  3. Double-layer versus single-layer bone-patellar tendon-bone anterior cruciate ligament reconstruction: a prospective randomized study with 3-year follow-up.

    PubMed

    Mei, Xiaoliang; Zhang, Zhenxiang; Yang, Jingwen

    2016-12-01

    To evaluate the clinical results of a randomized controlled trial of single-layer versus double-layer bone-patellar tendon-bone (BPTB) anterior cruciate ligament (ACL) reconstruction. Fifty-eight subjects who underwent primary ACL reconstruction with a BPTB allograft were prospectively randomized into two groups: single-layer reconstruction (n = 31) and double-layer reconstruction (n = 27). The following evaluation methods were used: clinical examination, KT-1000 arthrometer measurement, muscle strength, Tegner activity score, Lysholm score, subjective rating scale regarding patient satisfaction and sports performance level, graft retear, contralateral ACL tear, and additional meniscus surgery. Forty-eight subjects (24 in single-layer group and 24 in double-layer group) who were followed up for 3 years were evaluated. Preoperatively, there were no differences between the groups. At 3-year follow-up, the Lachman and pivot-shift test results were better in the double-layer group (P = 0.019 and P < 0.0001, respectively). KT measurements were better in the double-layer group (mean 2.9 versus 1.5 mm; P = 0.0025). The Tegner score was also better in the double-layer group (P = 0.024). There were no significant differences in range of motion, muscle strength, Lysholm score, subjective rating scale, graft retear, and secondary meniscal tear. In ACL reconstruction, double-layer BPTB reconstruction was significantly better than single-layer reconstruction regarding anterior and rotational stability at 3-year follow-up. The results of KT measurements and the Lachman and pivot-shift tests were significantly better in the double-layer group, whereas there was no difference in the anterior drawer test results. The Tegner score was also better in the double-layer group; however, there were no differences in the other subjective findings.

  4. Laboratory x-ray micro-computed tomography: a user guideline for biological samples

    PubMed Central

    2017-01-01

    Abstract Laboratory x-ray micro–computed tomography (micro-CT) is a fast-growing method in scientific research applications that allows for non-destructive imaging of morphological structures. This paper provides an easily operated “how to” guide for new potential users and describes the various steps required for successful planning of research projects that involve micro-CT. Background information on micro-CT is provided, followed by relevant setup, scanning, reconstructing, and visualization methods and considerations. Throughout the guide, a Jackson's chameleon specimen, which was scanned at different settings, is used as an interactive example. The ultimate aim of this paper is make new users familiar with the concepts and applications of micro-CT in an attempt to promote its use in future scientific studies. PMID:28419369

  5. Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments

    PubMed Central

    Elsherief, Samia M.; Zayet, Mohamed K.; Hamouda, Ibrahim M.

    2013-01-01

    Cone beam computed tomography is a 3-dimensional high resolution imaging method. The purpose of this study was to compare the effects of 3 different NiTi rotary instruments used to prepare curved root canals on the final shape of the curved canals and total amount of root canal transportation by using cone-beam computed tomography. A total of 81 mesial root canals from 42 extracted human mandibular molars, with a curvature ranging from 15 to 45 degrees, were selected. Canals were randomly divided into 3 groups of 27 each. After preparation with Protaper, Revo-S and Hero Shaper, the amount of transportation and centering ability that occurred were assessed by using cone beam computed tomography. Utilizing pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. Canals were metrically assessed for changes (surface area, changes in curvature and transportation) during canal preparation by using software SimPlant; instrument failures were also recorded. Mean total widths and outer and inner width measurements were determined on each central canal path and differences were statistically analyzed. The results showed that all instruments maintained the original canal curvature well with no significant differences between the different files (P = 0.226). During preparation there was failure of only one file (the protaper group). In conclusion, under the conditions of this study, all instruments maintained the original canal curvature well and were safe to use. Areas of uninstrumented root canal wall were left in all regions using the various systems. PMID:23885273

  6. Three-Dimensional P-wave Velocity Structure Beneath Long Valley Caldera, California, Using Local-Regional Double-Difference Tomography

    NASA Astrophysics Data System (ADS)

    Menendez, H. M.; Thurber, C. H.

    2011-12-01

    Eastern California's Long Valley Caldera (LVC) and the Mono-Inyo Crater volcanic systems have been active for the past ~3.6 million years. Long Valley is known to produce very large silicic eruptions, the last of which resulted in the formation of a 17 km by 32 km wide, east-west trending caldera. Relatively recent unrest began between 1978-1980 with five ML ≥ 5.7 non-double-couple (NDC) earthquakes and associated aftershock swarms. Similar shallow seismic swarms have continued south of the resurgent dome and beneath Mammoth Mountain, surrounding sites of increased CO2 gas emissions. Nearly two decades of increased volcanic activity led to the 1997 installation of a temporary three-component array of 69 seismometers. This network, deployed by the Durham University, the USGS, and Duke University, recorded over 4,000 high-frequency events from May to September. A local tomographic inversion of 283 events surrounding Mammoth Mountain yielded a velocity structure with low Vp and Vp/Vs anomalies at 2-3 km bsl beneath the resurgent dome and Casa Diablo hot springs. These anomalies were interpreted to be CO2 reservoirs (Foulger et al., 2003). Several teleseismic and regional tomography studies have also imaged low Vp anomalies beneath the caldera at ~5-15 km depth, interpreted to be the underlying magma reservoir (Dawson et al., 1990; Weiland et al., 1995; Thurber et al., 2009). This study aims to improve the resolution of the LVC regional velocity model by performing tomographic inversions using the local events from 1997 in conjunction with regional events recorded by the Northern California Seismic Network (NCSN) between 1980 and 2010 and available refraction data. Initial tomographic inversions reveal a low velocity zone at ~2 to 6 km depth beneath the caldera. This structure may simply represent the caldera fill. Further iterations and the incorporation of teleseismic data may better resolve the overall shape and size of the underlying magma reservoir.

  7. Analytical study and numerical solution of the inverse source problem arising in thermoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Holman, Benjamin R.

    In recent years, revolutionary "hybrid" or "multi-physics" methods of medical imaging have emerged. By combining two or three different types of waves these methods overcome limitations of classical tomography techniques and deliver otherwise unavailable, potentially life-saving diagnostic information. Thermoacoustic (and photoacoustic) tomography is the most developed multi-physics imaging modality. Thermo- and photo- acoustic tomography require reconstructing initial acoustic pressure in a body from time series of pressure measured on a surface surrounding the body. For the classical case of free space wave propagation, various reconstruction techniques are well known. However, some novel measurement schemes place the object of interest between reflecting walls that form a de facto resonant cavity. In this case, known methods cannot be used. In chapter 2 we present a fast iterative reconstruction algorithm for measurements made at the walls of a rectangular reverberant cavity with a constant speed of sound. We prove the convergence of the iterations under a certain sufficient condition, and demonstrate the effectiveness and efficiency of the algorithm in numerical simulations. In chapter 3 we consider the more general problem of an arbitrarily shaped resonant cavity with a non constant speed of sound and present the gradual time reversal method for computing solutions to the inverse source problem. It consists in solving back in time on the interval [0, T] the initial/boundary value problem for the wave equation, with the Dirichlet boundary data multiplied by a smooth cutoff function. If T is sufficiently large one obtains a good approximation to the initial pressure; in the limit of large T such an approximation converges (under certain conditions) to the exact solution.

  8. Load to Failure and Stiffness

    PubMed Central

    Esquivel, Amanda O.; Duncan, Douglas D.; Dobrasevic, Nikola; Marsh, Stephanie M.; Lemos, Stephen E.

    2015-01-01

    Background: Rotator cuff tendinopathy is a frequent cause of shoulder pain that can lead to decreased strength and range of motion. Failures after using the single-row technique of rotator cuff repair have led to the development of the double-row technique, which is said to allow for more anatomical restoration of the footprint. Purpose: To compare 5 different types of suture patterns while maintaining equality in number of anchors. The hypothesis was that the Mason-Allen–crossed cruciform transosseous-equivalent technique is superior to other suture configurations while maintaining equality in suture limbs and anchors. Study Design: Controlled laboratory study. Methods: A total of 25 fresh-frozen cadaveric shoulders were randomized into 5 suture configuration groups: single-row repair with simple stitch technique; single-row repair with modified Mason-Allen technique; double-row Mason-Allen technique; double-row cross-bridge technique; and double-row suture bridge technique. Load and displacement were recorded at 100 Hz until failure. Stiffness and bone mineral density were also measured. Results: There was no significant difference in peak load at failure, stiffness, maximum displacement at failure, or mean bone mineral density among the 5 suture configuration groups (P < .05). Conclusion: According to study results, when choosing a repair technique, other factors such as number of sutures in the repair should be considered to judge the strength of the repair. Clinical Relevance: Previous in vitro studies have shown the double-row rotator cuff repair to be superior to the single-row repair; however, clinical research does not necessarily support this. This study found no difference when comparing 5 different repair methods, supporting research that suggests the number of sutures and not the pattern can affect biomechanical properties. PMID:26665053

  9. Ischemic stroke enhancement in computed tomography scans using a computational approach

    NASA Astrophysics Data System (ADS)

    Alves, Allan F. F.; Pavan, Ana L. M.; Jennane, Rachid; Miranda, José R. A.; Freitas, Carlos C. M.; Abdala, Nitamar; Pina, Diana R.

    2018-03-01

    In this work, a novel approach was proposed to enhance the visual perception of ischemic stroke in computed tomography scans. Through different image processing techniques, we enabled less experienced physicians, to reliably detect early signs of stroke. A set of 40 retrospective CT scans of patients were used, divided into two groups: 25 cases of acute ischemic stroke and 15 normal cases used as control group. All cases were obtained within 4 hours of symptoms onset. Our approach was based on the variational decomposition model and three different segmentation methods. A test determined observers' performance to correctly diagnose stroke cases. The Expectation Maximization method provided the best results among all observers. The overall sensitivity of the observer's analysis was 64% and increased to 79%. The overall specificity was 67% and increased to 78%. These results show the importance of a computational tool to assist neuroradiology decisions, especially in critical situations such as the diagnosis of ischemic stroke.

  10. Automated detection of the retinal from OCT spectral domain images of healthy eyes

    NASA Astrophysics Data System (ADS)

    Giovinco, Gaspare; Savastano, Maria Cristina; Ventre, Salvatore; Tamburrino, Antonello

    2015-06-01

    Optical coherence tomography (OCT) has become one of the most relevant diagnostic tools for retinal diseases. Besides being a non-invasive technique, one distinguished feature is its unique capability of providing (in vivo) cross-sectional view of the retinal. Specifically, OCT images show the retinal layers. From the clinical point of view, the identification of the retinal layers opens new perspectives to study the correlation between morphological and functional aspects of the retinal tissue. The main contribution of this paper is a new method/algorithm for the automated segmentation of cross-sectional images of the retina of healthy eyes, obtained by means of spectral domain optical coherence tomography (SD-OCT). Specifically, the proposed segmentation algorithm provides the automated detection of different retinal layers. Tests on experimental SD-OCT scans performed by three different instruments/manufacturers have been successfully carried out and compared to a manual segmentation made by an independent ophthalmologist, showing the generality and the effectiveness of the proposed method.

  11. Automated detection of retinal layers from OCT spectral-domain images of healthy eyes

    NASA Astrophysics Data System (ADS)

    Giovinco, Gaspare; Savastano, Maria Cristina; Ventre, Salvatore; Tamburrino, Antonello

    2015-12-01

    Optical coherence tomography (OCT) has become one of the most relevant diagnostic tools for retinal diseases. Besides being a non-invasive technique, one distinguished feature is its unique capability of providing (in vivo) cross-sectional view of the retina. Specifically, OCT images show the retinal layers. From the clinical point of view, the identification of the retinal layers opens new perspectives to study the correlation between morphological and functional aspects of the retinal tissue. The main contribution of this paper is a new method/algorithm for the automated segmentation of cross-sectional images of the retina of healthy eyes, obtained by means of spectral-domain optical coherence tomography (SD-OCT). Specifically, the proposed segmentation algorithm provides the automated detection of different retinal layers. Tests on experimental SD-OCT scans performed by three different instruments/manufacturers have been successfully carried out and compared to a manual segmentation made by an independent ophthalmologist, showing the generality and the effectiveness of the proposed method.

  12. Snapshot polarization-sensitive plug-in optical module for a Fourier-domain optical coherence tomography system

    NASA Astrophysics Data System (ADS)

    Marques, Manuel J.; Rivet, Sylvain; Bradu, Adrian; Podoleanu, Adrian

    2018-02-01

    In this communication, we present a proof-of-concept polarization-sensitive Optical Coherence Tomography (PS-OCT) which can be used to characterize the retardance and the axis orientation of a linear birefringent sample. This module configuration is an improvement from our previous work1, 2 since it encodes the two polarization channels on the optical path difference, effectively carrying out the polarization measurements simultaneously (snapshot measurement), whilst retaining all the advantages (namely the insensitivity to environmental parameters when using SM fibers) of these two previous configurations. Further progress consists in employing Master Slave OCT technology,3 which is used to automatically compensate for the dispersion mismatch introduced by the elements in the module. This is essential given the encoding of the polarization states on two different optical path lengths, each of them having dissimilar dispersive properties. By utilizing this method instead of the commonly used re-linearization and numerical dispersion compensation methods an improvement in terms of the calculation time required can be achieved.

  13. Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads.

    PubMed

    Ma, Jieshi; Xu, Canhua; Dai, Meng; You, Fusheng; Shi, Xuetao; Dong, Xiuzhen; Fu, Feng

    2014-01-01

    Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.

  14. Exploratory Study on the Methodology of Fast Imaging of Unilateral Stroke Lesions by Electrical Impedance Asymmetry in Human Heads

    PubMed Central

    Xu, Canhua; Dai, Meng; You, Fusheng; Shi, Xuetao

    2014-01-01

    Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke. PMID:25006594

  15. Voxel based morphometry in optical coherence tomography: validation and core findings

    NASA Astrophysics Data System (ADS)

    Antony, Bhavna J.; Chen, Min; Carass, Aaron; Jedynak, Bruno M.; Al-Louzi, Omar; Solomon, Sharon D.; Saidha, Shiv; Calabresi, Peter A.; Prince, Jerry L.

    2016-03-01

    Optical coherence tomography (OCT) of the human retina is now becoming established as an important modality for the detection and tracking of various ocular diseases. Voxel based morphometry (VBM) is a long standing neuroimaging analysis technique that allows for the exploration of the regional differences in the brain. There has been limited work done in developing registration based methods for OCT, which has hampered the advancement of VBM analyses in OCT based population studies. Following on from our recent development of an OCT registration method, we explore the potential benefits of VBM analysis in cohorts of healthy controls (HCs) and multiple sclerosis (MS) patients. Specifically, we validate the stability of VBM analysis in two pools of HCs showing no significant difference between the two populations. Additionally, we also present a retrospective study of age and sex matched HCs and relapsing remitting MS patients, demonstrating results consistent with the reported literature while providing insight into the retinal changes associated with this MS subtype.

  16. Imaging vibration of the cochlear partition of an excised guinea pig cochlea using phase-sensitive Fourier domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Choudhury, Niloy; Zeng, Yaguang; Fridberger, Anders; Chen, Fangyi; Zha, Dingjun; Nuttall, Alfred L.; Wang, Ruikang K.

    2011-03-01

    Studying the sound stimulated vibrations of various membranes that form the complex structure of the organ of Corti in the cochlea of the inner ear is essential for understanding how the travelling sound wave of the basilar membrane couples its energy to the organ structures. In this paper we report the feasibility of using phase-sensitive Fourier domain optical coherence tomography (FD-OCT) to image the vibration of various micro-structures of the cochlea at the same time. An excised cochlea of a guinea pig was stimulated using sounds at various frequencies and vibration image was obtained. When measuring the apex area, vibration signal from different turns, which have different best response frequencies are obtained in the same image. The method has the potential to measure the response from a much wider region of the cochlea than any other currently used method. The noise floor for vibration image for the system at 200 Hz was ~0.3nm.

  17. Seismic velocity variations at the EGS geothermal reservoir of Soultz-Sous-Forêts (France): Some observations for understanding stress regime changes during hydraulic stimulations using 4D tomography

    NASA Astrophysics Data System (ADS)

    Calo, M.; Dorbath, C.; Cornet, F.; Cuenot, N.

    2011-12-01

    During the last decade three deep wells (GPK2, GPK3, and GPK4) were drilled to a depth of about 5000 m at the Enhanced Geothermal System (EGS) site of Soultz-sous-Forêts (Alsace, France). All the wells were stimulated through high-pressure hydraulic injections. Several thousands of micro-earthquakes with Duration Magnitude ranging from -0.9 to 2.9 were produced. The induced earthquakes were located by downhole and surface seismic stations. The wells behaved differently during and after the stimulations, as shown by several authors. We present here a comparison between new 4D seismic tomographies performed for the above mentioned stimulation tests. The velocity models have been obtained using the Double-Difference tomographic method (Zhang and Thurber 2003) and have been further improved with the post-processing WAM technique (Calo' et al., 2009, 2011). For each stimulation test, the subsetting of the data was performed by taking into account injection parameters (the injected flow rate and the wellhead pressure). In this work we discuss some important steps observed during and after the injections. A first observation is that low velocity anomalies were centered around the wells when stimulations started and then disappeared just after strong changes in the injected flow rate. We interpret these changes in seismic properties as transient changes in the stress regime during the stimulations. Furthermore, as shown by the seismic velocity models, pre-existing fracture network played a fundamental role on the intensity and distribution of the observed velocity anomalies. Indeed we observe that low velocity anomalies are much less evident and moved away from the well when documented large pre-exiting fractures cross the openhole part of the well. In particular, we observed this pattern for the models calculated with the data of the GPK3 stimulation. Thanks to the improvement and the reliability of these new velocity models, new discussions about the mechanical processes that occurred during the stimulations has been opened.

  18. Towards assessing corticospinal excitability bilaterally: Validation of a double-coil TMS method.

    PubMed

    Grandjean, Julien; Derosiere, Gerard; Vassiliadis, Pierre; Quemener, Louise; Wilde, Ysaline de; Duque, Julie

    2018-01-01

    For several decades, Transcranial magnetic stimulation (TMS) has been used to monitor corticospinal excitability (CSE) changes in various contexts. Habitually, single-coil TMS is applied over one primary motor cortex (M1), eliciting motor-evoked potentials (MEPs) in a contralateral limb muscle, usually a hand effector. However, in many situations, it would be useful to obtain MEPs in both hands simultaneously, to track CSE bilaterally. Such an approach requires stimulating both M1 concurrently while avoiding interference between the two descending stimuli. We examined MEPs obtained at rest using a double-coil TMS approach where the two M1 are stimulated with a 1ms inter-pulse interval (double-coil 1ms ). MEPs were acquired using double-coil 1ms (MEP double ) or single-coil (MEP single ) TMS, at five different intensities of stimulation (100, 115, 130, 145 or 160% of the resting motor threshold, rMT). Given the 1ms inter-pulse interval in double-coil 1ms trials, MEP double were either evoked by a 1st (MEP double-1 ) or a 2nd (MEP double-2 ) TMS pulse. All MEP TYPE (MEP TYPE =MEP single , MEP double-1 and MEP double-2 ) were equivalent, regardless of the hand within which they were elicited, the intensity of stimulation or the pulse order. This method allows one to observe state-related CSE changes for the two hands simultaneously on a trial-by-trial basis. These results infer the absence of any neural interactions between the two cortico-spinal volleys with double-coil 1ms TMS. Hence, this technique can be reliably used to assess CSE bilaterally, opening new research perspectives for scientists interested in physiological markers of activity in the motor output system. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Detection of admittivity anomaly on high-contrast heterogeneous backgrounds using frequency difference EIT.

    PubMed

    Jang, J; Seo, J K

    2015-06-01

    This paper describes a multiple background subtraction method in frequency difference electrical impedance tomography (fdEIT) to detect an admittivity anomaly from a high-contrast background conductivity distribution. The proposed method expands the use of the conventional weighted frequency difference EIT method, which has been used limitedly to detect admittivity anomalies in a roughly homogeneous background. The proposed method can be viewed as multiple weighted difference imaging in fdEIT. Although the spatial resolutions of the output images by fdEIT are very low due to the inherent ill-posedness, numerical simulations and phantom experiments of the proposed method demonstrate its feasibility to detect anomalies. It has potential application in stroke detection in a head model, which is highly heterogeneous due to the skull.

  20. Full moment tensor and source location inversion based on full waveform adjoint method

    NASA Astrophysics Data System (ADS)

    Morency, C.

    2012-12-01

    The development of high-performance computing and numerical techniques enabled global and regional tomography to reach high levels of precision, and seismic adjoint tomography has become a state-of-the-art tomographic technique. The method was successfully used for crustal tomography of Southern California (Tape et al., 2009) and Europe (Zhu et al., 2012). Here, I will focus on the determination of source parameters (full moment tensor and location) based on the same approach (Kim et al, 2011). The method relies on full wave simulations and takes advantage of the misfit between observed and synthetic seismograms. An adjoint wavefield is calculated by back-propagating the difference between observed and synthetics from the receivers to the source. The interaction between this adjoint wavefield and the regular forward wavefield helps define Frechet derivatives of the source parameters, that is, the sensitivity of the misfit with respect to the source parameters. Source parameters are then recovered by minimizing the misfit based on a conjugate gradient algorithm using the Frechet derivatives. First, I will demonstrate the method on synthetic cases before tackling events recorded at the Geysers. The velocity model used at the Geysers is based on the USGS 3D velocity model. Waveform datasets come from the Northern California Earthquake Data Center. Finally, I will discuss strategies to ultimately use this method to characterize smaller events for microseismic and induced seismicity monitoring. References: - Tape, C., Q. Liu, A. Maggi, and J. Tromp, 2009, Adjoint tomography of the Southern California crust: Science, 325, 988992. - Zhu, H., Bozdag, E., Peter, D., and Tromp, J., 2012, Structure of the European upper mantle revealed by adjoint method: Nature Geoscience, 5, 493-498. - Kim, Y., Q. Liu, and J. Tromp, 2011, Adjoint centroid-moment tensor inversions: Geophys. J. Int., 186, 264278. Prepared by LLNL under Contract DE-AC52-07NA27344.

  1. Optimization and evaluation of metal injection molding by using X-ray tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Shidi; Zhang, Ruijie; Qu, Xuanhui, E-mail: quxh@ustb.edu.cn

    2015-06-15

    6061 aluminum alloy and 316L stainless steel green bodies were obtained by using different injection parameters (injection pressure, speed and temperature). After injection process, the green bodies were scanned by X-ray tomography. The projection and reconstruction images show the different kinds of defects obtained by the improper injection parameters. Then, 3D rendering of the Al alloy green bodies was used to demonstrate the spatial morphology characteristics of the serious defects. Based on the scanned and calculated results, it is convenient to obtain the proper injection parameters for the Al alloy. Then, reasons of the defect formation were discussed. During moldmore » filling, the serious defects mainly formed in the case of low injection temperature and high injection speed. According to the gray value distribution of projection image, a threshold gray value was obtained to evaluate whether the quality of green body can meet the desired standard. The proper injection parameters of 316L stainless steel can be obtained efficiently by using the method of analyzing the Al alloy injection. - Highlights: • Different types of defects in green bodies were scanned by using X-ray tomography. • Reasons of the defect formation were discussed. • Optimization of the injection parameters can be simplified greatly by the way of X-ray tomography. • Evaluation standard of the injection process can be obtained by using the gray value distribution of projection image.« less

  2. Simulations of the flow past a cylinder using an unsteady double wake model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramos-García, N.; Sarlak, H.; Andersen, S. J.

    2016-06-08

    In the present work, the in-house UnSteady Double Wake Model (USDWM) is used to simulate flows past a cylinder at subcritical, supercritical, and transcritical Reynolds numbers. The flow model is a two-dimensional panel method which uses the unsteady double wake technique to model flow separation and its dynamics. In the present work the separation location is obtained from experimental data and fixed in time. The highly unsteady flow field behind the cylinder is analyzed in detail, comparing the vortex shedding charactericts under the different flow conditions.

  3. Development of high energy micro-tomography system at SPring-8

    NASA Astrophysics Data System (ADS)

    Uesugi, Kentaro; Hoshino, Masato

    2017-09-01

    A high energy X-ray micro-tomography system has been developed at BL20B2 in SPring-8. The available range of the energy is between 20keV and 113keV with a Si (511) double crystal monochromator. The system enables us to image large or heavy materials such as fossils and metals. The X-ray image detector consists of visible light conversion system and sCMOS camera. The effective pixel size is variable by changing a tandem lens between 6.5 μm/pixel and 25.5 μm/pixel discretely. The format of the camera is 2048 pixels x 2048 pixels. As a demonstration of the system, alkaline battery and a nodule from Bolivia were imaged. A detail of the structure of the battery and a female mold Trilobite were successfully imaged without breaking those fossils.

  4. Effect of the 5-HT(1A) partial agonist buspirone on regional brain electrical activity in man: a functional neuroimaging study using low-resolution electromagnetic tomography (LORETA).

    PubMed

    Anderer, P; Saletu, B; Pascual-Marqui, R D

    2000-12-04

    In a double-blind, placebo-controlled study, the effects of 20 mg buspirone - a 5-HT(1A) partial agonist - on regional electrical generators within the human brain were investigated utilizing three-dimensional EEG tomography. Nineteen-channel vigilance-controlled EEG recordings were carried out in 20 healthy subjects before and 1, 2, 4, 6 and 8 h after drug intake. Low-resolution electromagnetic tomography (LORETA; Key Institute for Brain-Mind Research, software: http://www.keyinst.unizh.ch) was computed from spectrally analyzed EEG data, and differences between drug- and placebo-induced changes were displayed as statistical parametric maps. Data were registered to the Talairach-Tournoux human brain atlas available as a digitized MRI (McConnell Brain Imaging Centre: http://www.bic.mni.mcgill.ca). At the pharmacodynamic peak (1st hour), buspirone increased theta and decreased fast alpha and beta sources. Areas of theta increase were mainly the left temporo-occipito-parietal and left prefrontal cortices, which is consistent with PET studies on buspirone-induced decreases in regional cerebral blood flow and fenfluramine-induced serotonin activation demonstrated by changes in regional cerebral glucose metabolism. In later hours (8th hour) with lower buspirone plasma levels, delta, theta, slow alpha and fast beta decreased, predominantly in the prefrontal and anterior limbic lobe. Whereas the results of the 1st hour speak for a slight CNS sedation (more in the sense of relaxation), those obtained in the 8th hour indicate activation. Thus, LORETA may provide useful and direct information on drug-induced changes in central nervous system function in man.

  5. Capacity Building for Sustainable Seismological Networks in the Americas: A Pan-American Advanced Studies Institute on New Frontiers in Seismological Research

    NASA Astrophysics Data System (ADS)

    Cabello, O. A.; Meltzer, A.; Sandvol, E. A.; Yepes, H.; Ruiz, M. C.; Barrientos, S. E.; Willemann, R. J.

    2011-12-01

    During July 2011, a Pan-American Advanced Studies Institute, "New Frontiers in Seismological Research: Sustainable Networks, Earthquake Source Parameters, and Earth Structure" was conducted in Quito Ecuador with participants from the US, Central, and South America, and the Caribbean at early stages in their scientific careers. This advanced studies institute was imparted by fifteen volunteer senior faculty and investigators from the U.S. and the Americas. The curriculum addressed the importance of developing and maintaining modern seismological observatories, reviewed the principles of sustainable network operations, and explored recent advances in the analysis of seismological data in support of basic research, education, and hazard mitigation. An additional goal was to develop future international research collaborations. The Institute engaged graduate students, post-doctoral students, and new faculty from across the Americas in an interactive collaborative learning environment including modules on double-difference earthquake location and tomography, regional centroid-moment tensors, and event-based and ambient noise surface wave dispersion and tomography. Under the faculty guidance, participants started promising research projects about surface wave tomography in southeastern Brazil, near the Chilean triple junction, in central Chilean Andes, at the Peru-Chile border, within Peru, at a volcano in Ecuador, in the Caribbean Sea region, and near the Mendocino triple junction. Other participants started projects about moment tensors of earthquakes in or near Brazil, Chile and Argentina, Costa Rica, Ecuador, Puerto Rico, western Mexico, and northern Mexico. In order to track the progress of the participants and measure the overall effectiveness of the Institute a reunion is planned where the PASI alumni will present the result of their research that was initiated in Quito

  6. Comparison of Single-Stick and Double-Stick Techniques for Percutaneous Nephrostomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Funaki, Brian, E-mail: bfunaki@midway.uchicago.edu; Vatakencherry, Geogi

    2004-01-15

    We compared single- and double-stick techniques of percutaneous nephrostomy insertion by retrospectively reviewing 140 percutaneous nephrostomy procedures in 101 patients. All procedures were performed by residents or fellows with direct attending supervision. Either the single-stick or double-stick technique was used based solely on personal attending preference. There were no significant differences in groups in terms of age, sex, or degree of hydronephrosis. In the single-stick technique, the kidney was punctured with sonographic guidance and the tract was serially dilated to accept an 8.5 Fr. nephrostomy catheter. In the double-stick technique, the kidney was punctured with sonographic guidance and a mixturemore » of air and contrast were injected into the collecting system. The affected side was then elevated and a posterior calyx was punctured using fluoroscopic guidance. Both groups were compared in terms of complications and early tube dysfunction using the chi-squared test. All procedures were successful without immediate complications. Bleeding requiring transfusion occurred in 4.7% (4/86) procedures in the single stick group and 3.7% (2/54) in the double stick group (p-value not significant). None of these patients required further interventions for bleeding. Tube dysfunction leading to premature tube exchange occurred in 3.5% (3/86) of catheters in the single stick group and 3.7% (2/54) of catheters in the double- stick group (p-value not significant). We found no significant difference between the single and double- stick methods of percutaneous nephrostomy in terms of success rates, complications, or tube function. We believe that the single-stick method should be adopted as the insertion technique of choice.« less

  7. Accuracy of volumetric measurement of simulated root resorption lacunas based on cone beam computed tomography.

    PubMed

    Wang, Y; He, S; Guo, Y; Wang, S; Chen, S

    2013-08-01

    To evaluate the accuracy of volumetric measurement of simulated root resorption cavities based on cone beam computed tomography (CBCT), in comparison with that of Micro-computed tomography (Micro-CT) which served as the reference. The State Key Laboratory of Oral Diseases at Sichuan University. Thirty-two bovine teeth were included for standardized CBCT scanning and Micro-CT scanning before and after the simulation of different degrees of root resorption. The teeth were divided into three groups according to the depths of the root resorption cavity (group 1: 0.15, 0.2, 0.3 mm; group 2: 0.6, 1.0 mm; group 3: 1.5, 2.0, 3.0 mm). Each depth included four specimens. Differences in tooth volume before and after simulated root resorption were then calculated from CBCT and Micro-CT scans, respectively. The overall between-method agreement of the measurements was evaluated using the concordance correlation coefficient (CCC). For the first group, the average volume of resorption cavity was 1.07 mm(3) , and the between-method agreement of measurement for the volume changes was low (CCC = 0.098). For the second and third groups, the average volumes of resorption cavities were 3.47 and 6.73 mm(3) respectively, and the between-method agreements were good (CCC = 0.828 and 0.895, respectively). The accuracy of 3-D quantitative volumetric measurement of simulated root resorption based on CBCT was fairly good in detecting simulated resorption cavities larger than 3.47 mm(3), while it was not sufficient for measuring resorption cavities smaller than 1.07 mm(3) . This method could be applied in future studies of root resorption although further studies are required to improve its accuracy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Computed tomography-based volumetric tool for standardized measurement of the maxillary sinus

    PubMed Central

    Giacomini, Guilherme; Pavan, Ana Luiza Menegatti; Altemani, João Mauricio Carrasco; Duarte, Sergio Barbosa; Fortaleza, Carlos Magno Castelo Branco; Miranda, José Ricardo de Arruda

    2018-01-01

    Volume measurements of maxillary sinus may be useful to identify diseases affecting paranasal sinuses. However, literature shows a lack of consensus in studies measuring the volume. This may be attributable to different computed tomography data acquisition techniques, segmentation methods, focuses of investigation, among other reasons. Furthermore, methods for volumetrically quantifying the maxillary sinus are commonly manual or semiautomated, which require substantial user expertise and are time-consuming. The purpose of the present study was to develop an automated tool for quantifying the total and air-free volume of the maxillary sinus based on computed tomography images. The quantification tool seeks to standardize maxillary sinus volume measurements, thus allowing better comparisons and determinations of factors that influence maxillary sinus size. The automated tool utilized image processing techniques (watershed, threshold, and morphological operators). The maxillary sinus volume was quantified in 30 patients. To evaluate the accuracy of the automated tool, the results were compared with manual segmentation that was performed by an experienced radiologist using a standard procedure. The mean percent differences between the automated and manual methods were 7.19% ± 5.83% and 6.93% ± 4.29% for total and air-free maxillary sinus volume, respectively. Linear regression and Bland-Altman statistics showed good agreement and low dispersion between both methods. The present automated tool for maxillary sinus volume assessment was rapid, reliable, robust, accurate, and reproducible and may be applied in clinical practice. The tool may be used to standardize measurements of maxillary volume. Such standardization is extremely important for allowing comparisons between studies, providing a better understanding of the role of the maxillary sinus, and determining the factors that influence maxillary sinus size under normal and pathological conditions. PMID:29304130

  9. Material characterization using ultrasound tomography

    NASA Astrophysics Data System (ADS)

    Falardeau, Timothe; Belanger, Pierre

    2018-04-01

    Characterization of material properties can be performed using a wide array of methods e.g. X-ray diffraction or tensile testing. Each method leads to a limited set of material properties. This paper is interested in using ultrasound tomography to map speed of sound inside a material sample. The velocity inside the sample is directly related to its elastic properties. Recent develop-ments in ultrasound diffraction tomography have enabled velocity mapping of high velocity contrast objects using a combination of bent-ray time-of-flight tomography and diffraction tomography. In this study, ultrasound diffraction tomography was investigated using simulations in human bone phantoms. A finite element model was developed to assess the influence of the frequency, the number of transduction positions and the distance from the sample as well as to adapt the imaging algorithm. The average velocity in both regions of the bone phantoms were within 5% of the true value.

  10. Online geometric calibration of cone-beam computed tomography for arbitrary imaging objects.

    PubMed

    Meng, Yuanzheng; Gong, Hui; Yang, Xiaoquan

    2013-02-01

    A novel online method based on the symmetry property of the sum of projections (SOP) is proposed to obtain the geometric parameters in cone-beam computed tomography (CBCT). This method requires no calibration phantom and can be used in circular trajectory CBCT with arbitrary cone angles. An objective function is deduced to illustrate the dependence of the symmetry of SOP on geometric parameters, which will converge to its minimum when the geometric parameters achieve their true values. Thus, by minimizing the objective function, we can obtain the geometric parameters for image reconstruction. To validate this method, numerical phantom studies with different noise levels are simulated. The results show that our method is insensitive to the noise and can determine the skew (in-plane rotation angle of the detector), the roll (rotation angle around the projection of the rotation axis on the detector), and the rotation axis with high accuracy, while the mid-plane and source-to-detector distance will be obtained with slightly lower accuracy. However, our simulation studies validate that the errors of the latter two parameters brought by our method will hardly degrade the quality of reconstructed images. The small animal studies show that our method is able to deal with arbitrary imaging objects. In addition, the results of the reconstructed images in different slices demonstrate that we have achieved comparable image quality in the reconstructions as some offline methods.

  11. Cadmium-Aluminum Layered Double Hydroxide Microspheres for Photocatalytic CO2 Reduction.

    PubMed

    Saliba, Daniel; Ezzeddine, Alaa; Sougrat, Rachid; Khashab, Niveen M; Hmadeh, Mohamad; Al-Ghoul, Mazen

    2016-04-21

    We report the synthesis of cadmium-aluminum layered double hydroxide (CdAl LDH) using the reaction-diffusion framework. As the hydroxide anions diffuse into an agar gel matrix containing the mixture of aluminum and cadmium salts at a given ratio, they react to give the LDH. The LDH self-assembles inside the pores of the gel matrix into a unique spherical-porous shaped microstructure. The internal and external morphologies of the particles are studied by electron microscopy and tomography revealing interconnected channels and a high surface area. This material is shown to exhibit a promising performance in the photoreduction of carbon dioxide using solar light. Moreover, the palladium-decorated version shows a significant improvement in its reduction potential at room temperature. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Linearization correction of /sup 99m/Tc-labeled hexamethyl-propylene amine oxime (HM-PAO) image in terms of regional CBF distribution: comparison to C VO2 inhalation steady-state method measured by positron emission tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inugami, A.; Kanno, I.; Uemura, K.

    1988-12-01

    The radioisotope distribution following intravenous injection of 99mTc-labeled hexamethylpropyleneamine oxime (HM-PAO) in the brain was measured by single photon emission computed tomography (SPECT) and corrected for the nonlinearity caused by differences in net extraction. The linearization correction was based on a three compartment model, and it required a region of reference to normalize the SPECT image in terms of regional cerebral blood flow distribution. Two different regions of reference, the cerebellum and the whole brain, were tested. The uncorrected and corrected HM-PAO images were compared with cerebral blood flow (CBF) image measured by the C VO2 inhalation steady state methodmore » and positron emission tomography (PET). The relationship between uncorrected HM-PAO and PET-CBF showed a correlation coefficient of 0.85 but tended to saturate at high CBF values, whereas it was improved to 0.93 after the linearization correction. The whole-brain normalization worked just as well as normalization using the cerebellum. This study constitutes a validation of the linearization correction and it suggests that after linearization the HM-PAO image may be scaled to absolute CBF by employing a global hemispheric CBF value as measured by the nontomographic TTXe clearance method.« less

  13. Nonuniform update for sparse target recovery in fluorescence molecular tomography accelerated by ordered subsets.

    PubMed

    Zhu, Dianwen; Li, Changqing

    2014-12-01

    Fluorescence molecular tomography (FMT) is a promising imaging modality and has been actively studied in the past two decades since it can locate the specific tumor position three-dimensionally in small animals. However, it remains a challenging task to obtain fast, robust and accurate reconstruction of fluorescent probe distribution in small animals due to the large computational burden, the noisy measurement and the ill-posed nature of the inverse problem. In this paper we propose a nonuniform preconditioning method in combination with L (1) regularization and ordered subsets technique (NUMOS) to take care of the different updating needs at different pixels, to enhance sparsity and suppress noise, and to further boost convergence of approximate solutions for fluorescence molecular tomography. Using both simulated data and phantom experiment, we found that the proposed nonuniform updating method outperforms its popular uniform counterpart by obtaining a more localized, less noisy, more accurate image. The computational cost was greatly reduced as well. The ordered subset (OS) technique provided additional 5 times and 3 times speed enhancements for simulation and phantom experiments, respectively, without degrading image qualities. When compared with the popular L (1) algorithms such as iterative soft-thresholding algorithm (ISTA) and Fast iterative soft-thresholding algorithm (FISTA) algorithms, NUMOS also outperforms them by obtaining a better image in much shorter period of time.

  14. Total variation iterative constraint algorithm for limited-angle tomographic reconstruction of non-piecewise-constant structures

    NASA Astrophysics Data System (ADS)

    Krauze, W.; Makowski, P.; Kujawińska, M.

    2015-06-01

    Standard tomographic algorithms applied to optical limited-angle tomography result in the reconstructions that have highly anisotropic resolution and thus special algorithms are developed. State of the art approaches utilize the Total Variation (TV) minimization technique. These methods give very good results but are applicable to piecewise constant structures only. In this paper, we propose a novel algorithm for 3D limited-angle tomography - Total Variation Iterative Constraint method (TVIC) which enhances the applicability of the TV regularization to non-piecewise constant samples, like biological cells. This approach consists of two parts. First, the TV minimization is used as a strong regularizer to create a sharp-edged image converted to a 3D binary mask which is then iteratively applied in the tomographic reconstruction as a constraint in the object domain. In the present work we test the method on a synthetic object designed to mimic basic structures of a living cell. For simplicity, the test reconstructions were performed within the straight-line propagation model (SIRT3D solver from the ASTRA Tomography Toolbox), but the strategy is general enough to supplement any algorithm for tomographic reconstruction that supports arbitrary geometries of plane-wave projection acquisition. This includes optical diffraction tomography solvers. The obtained reconstructions present resolution uniformity and general shape accuracy expected from the TV regularization based solvers, but keeping the smooth internal structures of the object at the same time. Comparison between three different patterns of object illumination arrangement show very small impact of the projection acquisition geometry on the image quality.

  15. San Miguel Volcanic Seismic and Structure in Central America: Insight into the Physical Processes of Volcanoes

    NASA Astrophysics Data System (ADS)

    Patlan, E.; Velasco, A.; Konter, J. G.

    2010-12-01

    The San Miguel volcano lies near the city of San Miguel, El Salvador (13.43N and - 88.26W). San Miguel volcano, an active stratovolcano, presents a significant natural hazard for the city of San Miguel. In general, the internal state and activity of volcanoes remains an important component to understanding volcanic hazard. The main technology for addressing volcanic hazards and processes is through the analysis of data collected from the deployment of seismic sensors that record ground motion. Six UTEP seismic stations were deployed around San Miguel volcano from 2007-2008 to define the magma chamber and assess the seismic and volcanic hazard. We utilize these data to develop images of the earth structure beneath the volcano, studying the volcanic processes by identifying different sources, and investigating the role of earthquakes and faults in controlling the volcanic processes. We initially locate events using automated routines and focus on analyzing local events. We then relocate each seismic event by hand-picking P-wave arrivals, and later refine these picks using waveform cross correlation. Using a double difference earthquake location algorithm (HypoDD), we identify a set of earthquakes that vertically align beneath the edifice of the volcano, suggesting that we have identified a magma conduit feeding the volcano. We also apply a double-difference earthquake tomography approach (tomoDD) to investigate the volcano’s plumbing system. Our preliminary results show the extent of the magma chamber that also aligns with some horizontal seismicity. Overall, this volcano is very active and presents a significant hazard to the region.

  16. Reliability of chemotherapy preparation processes: Evaluating independent double-checking and computer-assisted gravimetric control.

    PubMed

    Carrez, Laurent; Bouchoud, Lucie; Fleury-Souverain, Sandrine; Combescure, Christophe; Falaschi, Ludivine; Sadeghipour, Farshid; Bonnabry, Pascal

    2017-03-01

    Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, <5% deviation from the target concentration; weakly accurate, 5%-10%; inaccurate, 10%-30%; wrong, >30% deviation). Results Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods ( p = 0.63 Kruskal-Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Discussion Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.

  17. [Image reconstruction of conductivity on magnetoacoustic tomography with magnetic induction].

    PubMed

    Li, Jingyu; Yin, Tao; Liu, Zhipeng; Xu, Guohui

    2010-04-01

    The electric characteristics such as impedance and conductivity of the organization will change in the case where pathological changes occurred in the biological tissue. The change in electric characteristics usually took place before the change in the density of tissues, and also, the difference in electric characteristics such as conductivity between normal tissue and pathological tissue is obvious. The method of magneto-acoustic tomography with magnetic induction is based on the theory of magnetic eddy current induction, the principle of vibration generation and acoustic transmission to get the boundary of the pathological tissue. The pathological change could be inspected by electricity characteristic imaging which is invasive to the tissue. In this study, a two-layer concentric spherical model is established to simulate the malignant tumor tissue surrounded by normal tissue mutual relations of the magneto-sound coupling effect and the coupling equations in the magnetic field are used to get the algorithms for reconstructing the conductivity. Simulation study is conducted to test the proposed model and validate the performance of the reconstructed algorithms. The result indicates that the use of signal processing method in this paper can image the conductivity boundaries of the sample in the scanning cross section. The computer simulating results validate the feasibility of applying the method of magneto-acoustic tomography with magnetic induction for malignant tumor imaging.

  18. Improved tomographic reconstructions using adaptive time-dependent intensity normalization.

    PubMed

    Titarenko, Valeriy; Titarenko, Sofya; Withers, Philip J; De Carlo, Francesco; Xiao, Xianghui

    2010-09-01

    The first processing step in synchrotron-based micro-tomography is the normalization of the projection images against the background, also referred to as a white field. Owing to time-dependent variations in illumination and defects in detection sensitivity, the white field is different from the projection background. In this case standard normalization methods introduce ring and wave artefacts into the resulting three-dimensional reconstruction. In this paper the authors propose a new adaptive technique accounting for these variations and allowing one to obtain cleaner normalized data and to suppress ring and wave artefacts. The background is modelled by the product of two time-dependent terms representing the illumination and detection stages. These terms are written as unknown functions, one scaled and shifted along a fixed direction (describing the illumination term) and one translated by an unknown two-dimensional vector (describing the detection term). The proposed method is applied to two sets (a stem Salix variegata and a zebrafish Danio rerio) acquired at the parallel beam of the micro-tomography station 2-BM at the Advanced Photon Source showing significant reductions in both ring and wave artefacts. In principle the method could be used to correct for time-dependent phenomena that affect other tomographic imaging geometries such as cone beam laboratory X-ray computed tomography.

  19. New solutions and applications of 3D computer tomography image processing

    NASA Astrophysics Data System (ADS)

    Effenberger, Ira; Kroll, Julia; Verl, Alexander

    2008-02-01

    As nowadays the industry aims at fast and high quality product development and manufacturing processes a modern and efficient quality inspection is essential. Compared to conventional measurement technologies, industrial computer tomography (CT) is a non-destructive technology for 3D-image data acquisition which helps to overcome their disadvantages by offering the possibility to scan complex parts with all outer and inner geometric features. In this paper new and optimized methods for 3D image processing, including innovative ways of surface reconstruction and automatic geometric feature detection of complex components, are presented, especially our work of developing smart online data processing and data handling methods, with an integrated intelligent online mesh reduction. Hereby the processing of huge and high resolution data sets is guaranteed. Besides, new approaches for surface reconstruction and segmentation based on statistical methods are demonstrated. On the extracted 3D point cloud or surface triangulation automated and precise algorithms for geometric inspection are deployed. All algorithms are applied to different real data sets generated by computer tomography in order to demonstrate the capabilities of the new tools. Since CT is an emerging technology for non-destructive testing and inspection more and more industrial application fields will use and profit from this new technology.

  20. Computer Tomography and Hybrid Optical/Digital Methods for Aerodynamic Measurements.

    DTIC Science & Technology

    1987-12-28

    Industrial Applications of Corn- on Axisymnnietric Flame ’Iempnlw res Measured by Holo- puted Tornographv arid NMI? Imiaging (Optical Society of graphic...Pontificia Universidad Catolica de Chile. Escuela de Ingenieria . Santiago, equal. The optical path length difference (OPD) be- Chile. tween the two rays

  1. Tomography & Geochemistry: Precision, Repeatability, Accuracy and Joint Interpretations

    NASA Astrophysics Data System (ADS)

    Foulger, G. R.; Panza, G. F.; Artemieva, I. M.; Bastow, I. D.; Cammarano, F.; Doglioni, C.; Evans, J. R.; Hamilton, W. B.; Julian, B. R.; Lustrino, M.; Thybo, H.; Yanovskaya, T. B.

    2015-12-01

    Seismic tomography can reveal the spatial seismic structure of the mantle, but has little ability to constrain composition, phase or temperature. In contrast, petrology and geochemistry can give insights into mantle composition, but have severely limited spatial control on magma sources. For these reasons, results from these three disciplines are often interpreted jointly. Nevertheless, the limitations of each method are often underestimated, and underlying assumptions de-emphasized. Examples of the limitations of seismic tomography include its ability to image in detail the three-dimensional structure of the mantle or to determine with certainty the strengths of anomalies. Despite this, published seismic anomaly strengths are often unjustifiably translated directly into physical parameters. Tomography yields seismological parameters such as wave speed and attenuation, not geological or thermal parameters. Much of the mantle is poorly sampled by seismic waves, and resolution- and error-assessment methods do not express the true uncertainties. These and other problems have become highlighted in recent years as a result of multiple tomography experiments performed by different research groups, in areas of particular interest e.g., Yellowstone. The repeatability of the results is often poorer than the calculated resolutions. The ability of geochemistry and petrology to identify magma sources and locations is typically overestimated. These methods have little ability to determine source depths. Models that assign geochemical signatures to specific layers in the mantle, including the transition zone, the lower mantle, and the core-mantle boundary, are based on speculative models that cannot be verified and for which viable, less-astonishing alternatives are available. Our knowledge is poor of the size, distribution and location of protoliths, and of metasomatism of magma sources, the nature of the partial-melting and melt-extraction process, the mixing of disparate melts, and the re-assimilation of crust and mantle lithosphere by rising melt. Interpretations of seismic tomography, petrologic and geochemical observations, and all three together, are ambiguous, and this needs to be emphasized more in presenting interpretations so that the viability of the models can be assessed more reliably.

  2. High-field double-pancake superconducting coils and a method of winding

    DOEpatents

    Materna, P.A.

    1984-01-31

    A double-pancake coil having first and second pancakes may comprise a plurality of conductor means, each conductor means having a different grade and having one or more conductors, wherein each pancake of said double-pancake coil is comprised of inner and outer turns; wherein said inner turns are comprised of at least one of said conductor means wound about an axis and nested within one another; wherein said outer turns are comprised of said inner conductor means and at least one other conductor means co-wound about said inner turns and nested within one another; wherein each of said conductor means is wound along said axis from said first pancake to said second pancake at a different turn.

  3. High-field double-pancake superconducting coils and a method of winding

    DOEpatents

    Materna, Peter A.

    1985-01-01

    A double-pancake coil having first and second pancakes may comprise a plurality of conductor means, each conductor means having a different grade and having one or more conductors, wherein each pancake of said double-pancake coil is comprised of inner and outer turns; wherein said inner turns are comprised of at least one of said conductor means wound about an axis and nested within one another; wherein said outer turns are comprised of said inner conductor means and at least one other conductor means co-wound about said inner turns and nested within one another; wherein each of said conductor means is wound along said axis from said first pancake to said second pancake at a different turn.

  4. Advanced Multivariate Inversion Techniques for High Resolution 3D Geophysical Modeling (Invited)

    NASA Astrophysics Data System (ADS)

    Maceira, M.; Zhang, H.; Rowe, C. A.

    2009-12-01

    We focus on the development and application of advanced multivariate inversion techniques to generate a realistic, comprehensive, and high-resolution 3D model of the seismic structure of the crust and upper mantle that satisfies several independent geophysical datasets. Building on previous efforts of joint invesion using surface wave dispersion measurements, gravity data, and receiver functions, we have added a fourth dataset, seismic body wave P and S travel times, to the simultaneous joint inversion method. We present a 3D seismic velocity model of the crust and upper mantle of northwest China resulting from the simultaneous, joint inversion of these four data types. Surface wave dispersion measurements are primarily sensitive to seismic shear-wave velocities, but at shallow depths it is difficult to obtain high-resolution velocities and to constrain the structure due to the depth-averaging of the more easily-modeled, longer-period surface waves. Gravity inversions have the greatest resolving power at shallow depths, and they provide constraints on rock density variations. Moreover, while surface wave dispersion measurements are primarily sensitive to vertical shear-wave velocity averages, body wave receiver functions are sensitive to shear-wave velocity contrasts and vertical travel-times. Addition of the fourth dataset, consisting of seismic travel-time data, helps to constrain the shear wave velocities both vertically and horizontally in the model cells crossed by the ray paths. Incorporation of both P and S body wave travel times allows us to invert for both P and S velocity structure, capitalizing on empirical relationships between both wave types’ seismic velocities with rock densities, thus eliminating the need for ad hoc assumptions regarding the Poisson ratios. Our new tomography algorithm is a modification of the Maceira and Ammon joint inversion code, in combination with the Zhang and Thurber TomoDD (double-difference tomography) program.

  5. Tomography by iterative convolution - Empirical study and application to interferometry

    NASA Technical Reports Server (NTRS)

    Vest, C. M.; Prikryl, I.

    1984-01-01

    An algorithm for computer tomography has been developed that is applicable to reconstruction from data having incomplete projections because an opaque object blocks some of the probing radiation as it passes through the object field. The algorithm is based on iteration between the object domain and the projection (Radon transform) domain. Reconstructions are computed during each iteration by the well-known convolution method. Although it is demonstrated that this algorithm does not converge, an empirically justified criterion for terminating the iteration when the most accurate estimate has been computed is presented. The algorithm has been studied by using it to reconstruct several different object fields with several different opaque regions. It also has been used to reconstruct aerodynamic density fields from interferometric data recorded in wind tunnel tests.

  6. Young's double-slit interference with two-color biphotons.

    PubMed

    Zhang, De-Jian; Wu, Shuang; Li, Hong-Guo; Wang, Hai-Bo; Xiong, Jun; Wang, Kaige

    2017-12-12

    In classical optics, Young's double-slit experiment with colored coherent light gives rise to individual interference fringes for each light frequency, referring to single-photon interference. However, two-photon double-slit interference has been widely studied only for wavelength-degenerate biphoton, known as subwavelength quantum lithography. In this work, we report double-slit interference experiments with two-color biphoton. Different from the degenerate case, the experimental results depend on the measurement methods. From a two-axis coincidence measurement pattern we can extract complete interference information about two colors. The conceptual model provides an intuitional picture of the in-phase and out-of-phase photon correlations and a complete quantum understanding about the which-path information of two colored photons.

  7. Generating multi-double-scroll attractors via nonautonomous approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Qinghui; Xie, Qingguo, E-mail: qgxie@mail.hust.edu.cn; Shen, Yi

    It is a common phenomenon that multi-scroll attractors are realized by introducing the various nonlinear functions with multiple breakpoints in double scroll chaotic systems. Differently, we present a nonautonomous approach for generating multi-double-scroll attractors (MDSA) without changing the original nonlinear functions. By using the multi-level-logic pulse excitation technique in double scroll chaotic systems, MDSA can be generated. A Chua's circuit, a Jerk circuit, and a modified Lorenz system are given as designed example and the Matlab simulation results are presented. Furthermore, the corresponding realization circuits are designed. The Pspice results are in agreement with numerical simulation results, which verify themore » availability and feasibility of this method.« less

  8. Wide baseline stereo matching based on double topological relationship consistency

    NASA Astrophysics Data System (ADS)

    Zou, Xiaohong; Liu, Bin; Song, Xiaoxue; Liu, Yang

    2009-07-01

    Stereo matching is one of the most important branches in computer vision. In this paper, an algorithm is proposed for wide-baseline stereo vision matching. Here, a novel scheme is presented called double topological relationship consistency (DCTR). The combination of double topological configuration includes the consistency of first topological relationship (CFTR) and the consistency of second topological relationship (CSTR). It not only sets up a more advanced model on matching, but discards mismatches by iteratively computing the fitness of the feature matches and overcomes many problems of traditional methods depending on the powerful invariance to changes in the scale, rotation or illumination across large view changes and even occlusions. Experimental examples are shown where the two cameras have been located in very different orientations. Also, epipolar geometry can be recovered using RANSAC by far the most widely method adopted possibly. By the method, we can obtain correspondences with high precision on wide baseline matching problems. Finally, the effectiveness and reliability of this method are demonstrated in wide-baseline experiments on the image pairs.

  9. {sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanoun, Salim, E-mail: Salim.kanoun@gmail.com; LE2I UMR6306, Centre national de la recherche scientifique, Arts et Métiers, Université Bourgogne Franche-Comté, Dijon; MRI Unit, Centre Hospitalier Régional Universitaire, Hôpital François Mitterrand, Dijon

    Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence.more » Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.« less

  10. Spectrally resolving and scattering-compensated x-ray luminescence/fluorescence computed tomography

    PubMed Central

    Cong, Wenxiang; Shen, Haiou; Wang, Ge

    2011-01-01

    The nanophosphors, or other similar materials, emit near-infrared (NIR) light upon x-ray excitation. They were designed as optical probes for in vivo visualization and analysis of molecular and cellular targets, pathways, and responses. Based on the previous work on x-ray fluorescence computed tomography (XFCT) and x-ray luminescence computed tomography (XLCT), here we propose a spectrally-resolving and scattering-compensated x-ray luminescence/fluorescence computed tomography (SXLCT or SXFCT) approach to quantify a spatial distribution of nanophosphors (other similar materials or chemical elements) within a biological object. In this paper, the x-ray scattering is taken into account in the reconstruction algorithm. The NIR scattering is described in the diffusion approximation model. Then, x-ray excitations are applied with different spectra, and NIR signals are measured in a spectrally resolving fashion. Finally, a linear relationship is established between the nanophosphor distribution and measured NIR data using the finite element method and inverted using the compressive sensing technique. The numerical simulation results demonstrate the feasibility and merits of the proposed approach. PMID:21721815

  11. A spatially adaptive total variation regularization method for electrical resistance tomography

    NASA Astrophysics Data System (ADS)

    Song, Xizi; Xu, Yanbin; Dong, Feng

    2015-12-01

    The total variation (TV) regularization method has been used to solve the ill-posed inverse problem of electrical resistance tomography (ERT), owing to its good ability to preserve edges. However, the quality of the reconstructed images, especially in the flat region, is often degraded by noise. To optimize the regularization term and the regularization factor according to the spatial feature and to improve the resolution of reconstructed images, a spatially adaptive total variation (SATV) regularization method is proposed. A kind of effective spatial feature indicator named difference curvature is used to identify which region is a flat or edge region. According to different spatial features, the SATV regularization method can automatically adjust both the regularization term and regularization factor. At edge regions, the regularization term is approximate to the TV functional to preserve the edges; in flat regions, it is approximate to the first-order Tikhonov (FOT) functional to make the solution stable. Meanwhile, the adaptive regularization factor determined by the spatial feature is used to constrain the regularization strength of the SATV regularization method for different regions. Besides, a numerical scheme is adopted for the implementation of the second derivatives of difference curvature to improve the numerical stability. Several reconstruction image metrics are used to quantitatively evaluate the performance of the reconstructed results. Both simulation and experimental results indicate that, compared with the TV (mean relative error 0.288, mean correlation coefficient 0.627) and FOT (mean relative error 0.295, mean correlation coefficient 0.638) regularization methods, the proposed SATV (mean relative error 0.259, mean correlation coefficient 0.738) regularization method can endure a relatively high level of noise and improve the resolution of reconstructed images.

  12. The Electron Density Features Revealed by the GNSS-Based Radio Tomography in the Different Latitudinal and Longitudinal Sectors of the Ionosphere

    NASA Astrophysics Data System (ADS)

    Andreeva, Elena; Tereshchenko, Evgeniy; Nazarenko, Marina; Nesterov, Ivan; Kozharin, Maksim; Padokhin, Artem; Tumanova, Yulia

    2016-04-01

    The ionospheric radio tomography is an efficient method for electron density imaging in the different geographical regions of the world under different space weather conditions. The input for the satellite-based ionospheric radio tomography is provided by the signals that are transmitted from the navigational satellites and recorded by the chains or networks of ground receivers. The low-orbiting (LO) radio tomography employs the 150/400 MHz radio transmissions from the Earth's orbiters (like the Russian Tsikada/Parus and American Transit) flying at a height of ~1000 km above the Earth in the nearly polar orbits. The phases of the signals from a moving satellite which are recorded by the chains of ground receivers oriented along the satellite path form the families of linear integrals of electron density along the satellite-receiver rays that are used as the input data for LORT. The LO tomographic inversion of these data by phase difference method yields the 2D distributions of the ionospheric plasma in the vertical plane containing the receiving chain and the satellite path. LORT provides vertical resolution of 20-30 km and horizontal resolution of 30-40 km. The high-orbiting (HO) radio tomography employs the radio transmissions from the GPS/GLONASS satellites and enables 4D imaging of the ionosphere (3 spatial coordinates and time). HORT has a much wider spatial coverage (almost worldwide) and provides continuous time series of the reconstructions. However, the spatial resolution of HORT is lower (~100 km horizontally with a time step 60-20 min). In the regions with dense receiving networks (Europe, USA, Alaska, Japan), the resolution can be increased to 30-50 km with a time interval of 30-10 min. To date, the extensive RT data collected from the existing RT chains and networks enable a thorough analysis of both the regular and sporadic ionospheric features which are observed systematically or appear spontaneously, whose origin is fairly well understood or requires a dedicated study. We present the examples of the both types of the structures. We show a collection of different ionospheric structures under different space weather conditions: the ionization troughs, with their widely varying shapes, depths, positions, and internal distributions of plasma; isolated spots of the increased or decreased electron density, sharp wall-like density gradients, blobs, wavelike disturbances on different spatiotemporal scales etc. We demonstrate the series of the local isolated irregularities which are observed during both the quiet and disturbed days. We show the examples of the ionospheric plasma distributions strikingly varying during the geomagnetic storms. Some of the RT data are compared to the independent observations by the ionosondes. We also present the examples of RT images comparison with the UV spectroscopy data.

  13. Whole-Body Computed Tomography-Based Body Mass and Body Fat Quantification: A Comparison to Hydrostatic Weighing and Air Displacement Plethysmography.

    PubMed

    Gibby, Jacob T; Njeru, Dennis K; Cvetko, Steve T; Heiny, Eric L; Creer, Andrew R; Gibby, Wendell A

    We correlate and evaluate the accuracy of accepted anthropometric methods of percent body fat (%BF) quantification, namely, hydrostatic weighing (HW) and air displacement plethysmography (ADP), to 2 automatic adipose tissue quantification methods using computed tomography (CT). Twenty volunteer subjects (14 men, 6 women) received head-to-toe CT scans. Hydrostatic weighing and ADP were obtained from 17 and 12 subjects, respectively. The CT data underwent conversion using 2 separate algorithms, namely, the Schneider method and the Beam method, to convert Hounsfield units to their respective tissue densities. The overall mass and %BF of both methods were compared with HW and ADP. When comparing ADP to CT data using the Schneider method and Beam method, correlations were r = 0.9806 and 0.9804, respectively. Paired t tests indicated there were no statistically significant biases. Additionally, observed average differences in %BF between ADP and the Schneider method and the Beam method were 0.38% and 0.77%, respectively. The %BF measured from ADP, the Schneider method, and the Beam method all had significantly higher mean differences when compared with HW (3.05%, 2.32%, and 1.94%, respectively). We have shown that total body mass correlates remarkably well with both the Schneider method and Beam method of mass quantification. Furthermore, %BF calculated with the Schneider method and Beam method CT algorithms correlates remarkably well with ADP. The application of these CT algorithms have utility in further research to accurately stratify risk factors with periorgan, visceral, and subcutaneous types of adipose tissue, and has the potential for significant clinical application.

  14. Practical Bayesian tomography

    NASA Astrophysics Data System (ADS)

    Granade, Christopher; Combes, Joshua; Cory, D. G.

    2016-03-01

    In recent years, Bayesian methods have been proposed as a solution to a wide range of issues in quantum state and process tomography. State-of-the-art Bayesian tomography solutions suffer from three problems: numerical intractability, a lack of informative prior distributions, and an inability to track time-dependent processes. Here, we address all three problems. First, we use modern statistical methods, as pioneered by Huszár and Houlsby (2012 Phys. Rev. A 85 052120) and by Ferrie (2014 New J. Phys. 16 093035), to make Bayesian tomography numerically tractable. Our approach allows for practical computation of Bayesian point and region estimators for quantum states and channels. Second, we propose the first priors on quantum states and channels that allow for including useful experimental insight. Finally, we develop a method that allows tracking of time-dependent states and estimates the drift and diffusion processes affecting a state. We provide source code and animated visual examples for our methods.

  15. Stereo-tomography in triangulated models

    NASA Astrophysics Data System (ADS)

    Yang, Kai; Shao, Wei-Dong; Xing, Feng-yuan; Xiong, Kai

    2018-04-01

    Stereo-tomography is a distinctive tomographic method. It is capable of estimating the scatterer position, the local dip of scatterer and the background velocity simultaneously. Building a geologically consistent velocity model is always appealing for applied and earthquake seismologists. Differing from the previous work to incorporate various regularization techniques into the cost function of stereo-tomography, we think extending stereo-tomography to the triangulated model will be the most straightforward way to achieve this goal. In this paper, we provided all the Fréchet derivatives of stereo-tomographic data components with respect to model components for slowness-squared triangulated model (or sloth model) in 2D Cartesian coordinate based on the ray perturbation theory for interfaces. A sloth model representation means a sparser model representation when compared with conventional B-spline model representation. A sparser model representation leads to a smaller scale of stereo-tomographic (Fréchet) matrix, a higher-accuracy solution when solving linear equations, a faster convergence rate and a lower requirement for quantity of data space. Moreover, a quantitative representation of interface strengthens the relationships among different model components, which makes the cross regularizations among these model components, such as node coordinates, scatterer coordinates and scattering angles, etc., more straightforward and easier to be implemented. The sensitivity analysis, the model resolution matrix analysis and a series of synthetic data examples demonstrate the correctness of the Fréchet derivatives, the applicability of the regularization terms and the robustness of the stereo-tomography in triangulated model. It provides a solid theoretical foundation for the real applications in the future.

  16. SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeh, M; Wang, Y; Weng, H

    Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less

  17. [Evaluation of diabetic microangiopathy using optical coherence tomography angiography].

    PubMed

    Czakó, Cecília; Sándor, Gábor László; Ecsedy, Mónika; Szepessy, Zsuzsanna; Borbándy, Ágnes; Resch, Miklós; Papp, András; Récsán, Zsuzsa; Horváth, Hajnalka; Nagy, Zoltán Zsolt; Kovács, Illés

    2018-02-01

    Optical coherence tomography angiography is a non-invasive imaging technique that is able to visualize the different retinal vascular layers using motion contrast to detect blood flow without intravenous dye injection. This method might help to assess microangiopathy in diabetic retinopathy during screening and follow-up. To quantify retinal microvasculature alterations in both eyes of diabetic patients in relation to systemic risk factors using optical coherence tomography angiography. Both eyes of 36 diabetic patients and 45 individuals without diabetes were examined. Duration of diabetes, insulin therapy, blood pressure, HbA 1c , dyslipidemia, axial length and the presence of diabetic retinopathy were recorded. Retinal vessel density was measured by optical coherence tomography angiography. The effect of risk factors on vessel density and between-eye asymmetry was assessed using multivariable regression analysis. Vessel density was significantly lower and between-eye difference was significantly higher in diabetic patients compared to controls (p<0.05). Both vessel density and between-eye asymmetry significantly correlated with diabetes duration (p<0.05) after controlling for the effect of risk factors. The between-eye asymmetry in vessel density was significantly higher in patients without clinically detectable diabetic retinopathy compared to control subjects (p<0.001). There is a decrease in retinal vessel density and an increase in between-eye asymmetry in patients with diabetes compared to healthy subjects. By using optical coherence tomography angiography, the detection of these microvascular alterations is possible before clinically detectable diabetic retinopathy and might serve as a useful tool in both screening and timing of treatment. Orv Hetil. 2018; 159(8): 320-326.

  18. Biological soft X-ray tomography on beamline 2.1 at the Advanced Light Source.

    PubMed

    Le Gros, Mark A; McDermott, Gerry; Cinquin, Bertrand P; Smith, Elizabeth A; Do, Myan; Chao, Weilun L; Naulleau, Patrick P; Larabell, Carolyn A

    2014-11-01

    Beamline 2.1 (XM-2) is a transmission soft X-ray microscope in sector 2 of the Advanced Light Source at Lawrence Berkeley National Laboratory. XM-2 was designed, built and is now operated by the National Center for X-ray Tomography as a National Institutes of Health Biomedical Technology Research Resource. XM-2 is equipped with a cryogenic rotation stage to enable tomographic data collection from cryo-preserved cells, including large mammalian cells. During data collection the specimen is illuminated with `water window' X-rays (284-543 eV). Illuminating photons are attenuated an order of magnitude more strongly by biomolecules than by water. Consequently, differences in molecular composition generate quantitative contrast in images of the specimen. Soft X-ray tomography is an information-rich three-dimensional imaging method that can be applied either as a standalone technique or as a component modality in correlative imaging studies.

  19. Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures

    PubMed Central

    Neogi, Devdatta Suhas; Trikha, Vivek; Mishra, Kaushal Kant; Bandekar, Shivanand M.; Yadav, Chandra Shekhar

    2015-01-01

    Background: Bicondylar tibial plateau fractures are complex injuries and treatment is challenging. Ideal method is still controversial with risk of unsatisfactory results if not treated properly. Many different techniques of internal and external fixation are used. This study compares the clinical results in single locked plating versus dual plating (DP) using two incision approaches. Our hypothesis was that DP leads to less collapse and change in alignment at final followup compared with single plating. Materials and Methods: 61 cases of Type C tibial plateau fractures operated between January 2007 and June 2011 were included in this prospective study. All cases were operated either by single lateral locked plate by anterolateral approach or double plating through double incision. All cases were followed for a minimum of 24 months radiologically and clinically. The statistical analysis was performed using software SPSS 10.0 to analyze the data. Results: Twenty nine patients in a single lateral locked plate and 32 patients in a double plating group were followed for minimum 2 years. All fractures healed, however there was a significant incidence of malalignment in the single lateral plating group. Though there was a significant increase in soft tissue issues with the double plating group; however, there was only 3.12% incidence of deep infection. There was no significant difference in Hospital for special surgery score at 2 years followup. Conclusion: Double plating through two incisions resulted in a better limb alignment and joint reduction with an acceptable soft tissue complication rate. PMID:26015609

  20. Synchronous Double Malignant Tumors Consisting of Stomach and Hodgkin's Lymphoma with Collision between Gastric Adenocarcinoma and Hodgkin's Lymphoma in the Stomach.

    PubMed

    Yanagawa, Naoki; Ogata, Shin-Ya; Fukushima, Norimasa; Maeda, Kunihiko; Tamura, Gen

    2012-09-01

    We report the rare case of a 72-year-old man with double cancers (gastric adenocarcinoma and Hodgkin's lymphoma) with collision between gastric adenocarcinoma and Hodgkin's lymphoma. Abdominal computed tomography showed increased wall thickness in the fundus region of the stomach and multiple lymph node swellings in the lesser curvature, periceliac and left cardial regions. Upper gastrointestinal endoscopy showed an ulcer approximately 5 cm in diameter with a malignant appearance in the fundus region of the stomach. On histopathologic examination, two completely different tumors were recognized in the stomach. One tumor was a poorly differentiated adenocarcinoma characterized by poorly developed tubular structures associated with prominent lymphoid infiltration of the stroma. The other tumor was found to have proliferated in the wall of the stomach, with diffuse granulomatous lesions and bordering the adenocarcinoma. Large atypical lymphoid cells with prominent nucleoli and enlarged mononuclei or multinuclei were seen in the latter tumor. Hodgkin's lymphoma was also found in the swollen lesser curvature lymph nodes. As a result, gastric adenocarcinoma and metastasis of Hodgkin's lymphoma were collided in the stomach. In conclusion, this case might be helpful in exploring the occurrence mechanism of tumor collision between lymphoma and carcinoma.

  1. [A method for rapid extracting three-dimensional root model of vivo tooth from cone beam computed tomography data based on the anatomical characteristics of periodontal ligament].

    PubMed

    Zhao, Y J; Wang, S W; Liu, Y; Wang, Y

    2017-02-18

    To explore a new method for rapid extracting and rebuilding three-dimensional (3D) digital root model of vivo tooth from cone beam computed tomography (CBCT) data based on the anatomical characteristics of periodontal ligament, and to evaluate the extraction accuracy of the method. In the study, 15 extracted teeth (11 with single root, 4 with double roots) were collected from oral clinic and 3D digital root models of each tooth were obtained by 3D dental scanner with a high accuracy 0.02 mm in STL format. CBCT data for each patient were acquired before tooth extraction, DICOM data with a voxel size 0.3 mm were input to Mimics 18.0 software. Segmentation, Morphology operations, Boolean operations and Smart expanded function in Mimics software were used to edit teeth, bone and periodontal ligament threshold mask, and root threshold mask were automatically acquired after a series of mask operations. 3D digital root models were extracted in STL format finally. 3D morphology deviation between the extracted root models and corresponding vivo root models were compared in Geomagic Studio 2012 software. The 3D size errors in long axis, bucco-lingual direction and mesio-distal direction were also calculated. The average value of the 3D morphology deviation for 15 roots by calculating Root Mean Square (RMS) value was 0.22 mm, the average size errors in the mesio-distal direction, the bucco-lingual direction and the long axis were 0.46 mm, 0.36 mm and -0.68 mm separately. The average time of this new method for extracting single root was about 2-3 min. It could meet the accuracy requirement of the root 3D reconstruction fororal clinical use. This study established a new method for rapid extracting 3D root model of vivo tooth from CBCT data. It could simplify the traditional manual operation and improve the efficiency and automation of single root extraction. The strategy of this method for complete dentition extraction needs further research.

  2. Determination of Root Canal Cleanliness by Different Irrigation Methods and Morphometric Analysis of Apical Third.

    PubMed

    Seixas, Fábio Heredia; Estrela, Carlos; Bueno, Mike Reis; Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma

    2015-06-01

    The aim of this study was to determine the root canal area before and after the instrumentation 1 mm short of the apical foramen by clinical and cone beam computed tomography (CBCT) methods, and to evaluate the cleanliness of the apical region in mesiodistal flattened teeth by using optical microscopy. Forty-two human single-canal mandibular incisors were instrumented using the Free Tip Preparation technique up to three, four or five instruments from the initial. Cone beam computed tomography scans were acquired of the samples before and after root canal preparation (RCP). Irrigation was performed by conventional or hydrodynamic means, using 2.5% sodium hypochlorite. The samples were prepared for observation under an optical microscope. Images were digitally obtained, analyzed and the results were submitted to statistical analysis (two-way ANOVA complemented by Bonferroni's post-test). There was no significant difference between the studied anatomical areas with both CBCT and clinical methods. There were no differences between irrigation methods. It was verified differences between instrumentation techniques. Instrumentation with four instruments from the initial instrument determined a significant increase in the contact area when compared to preparation with three instruments, but RCP with 5 instruments did not result in a better cleanliness. The analysis with CBCT was not capable to determine the precise shape of surgical apical area comparing to the clinical method. Both the conventional and hydrodynamic irrigation techniques were not able to promote root canals debris-free. The instruments action in root canal walls was proportional to the number of instruments used from the initial apical instrument.

  3. Multiple composite grafts (k, π or double-Y) in coronary artery surgery: a choice or a necessity?

    PubMed

    Mannacio, Vito; Cirillo, Plinio; Mannacio, Luigi; Antignano, Anita; Mottola, Michele; Vosa, Carlo

    2015-01-01

    Composite grafts allow complete arterial revascularization with minimal aortic manipulations. The Y-T configuration supplies all distal branches adequately, whereas it is unclear whether complex composite configurations (K, Π or double-Y) are equally at rest or when challenged by maximal requirements. Forty-seven patients who underwent off-pump coronary artery revascularization by multiple arterial composite grafts (K, Π or double-Y) were retrospectively evaluated. Indication for this surgical option was porcelain aorta or conduit unavailability. Composite systems were evaluated by intraoperative flow measurements and perioperative transthoracic Doppler ultrasonography, 12 months later also by exercise test, sestamibi scintigraphy at rest and during induced hyperaemia and by 64-slice multidetector CT angiography. A total of 141 distal anastomoses were implanted as composite grafts. Perioperative flow measurements and 12-month Doppler ultrasonography were adequate at rest. At stress test, chest pain and/or induced ECG evidence of ischaemia are found in 16 patients (39%). During dipyridamole-induced hyperaemia, single-photon emission computed tomography image revealed that mean summed stress score was 7.2 ± 5.7, summed difference score 5.3 ± 4.2 and coronary flow reserve 1.7 ± 0.2. Multiple composite grafts, albeit adequate at rest, were unable to meet flow requirements during maximal hyperaemia. In daily practice, their use must be not a choice but rather a necessity in those patients without alternative options. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Image reconstruction of x-ray tomography by using image J platform

    NASA Astrophysics Data System (ADS)

    Zain, R. M.; Razali, A. M.; Salleh, K. A. M.; Yahya, R.

    2017-01-01

    A tomogram is a technical term for a CT image. It is also called a slice because it corresponds to what the object being scanned would look like if it were sliced open along a plane. A CT slice corresponds to a certain thickness of the object being scanned. So, while a typical digital image is composed of pixels, a CT slice image is composed of voxels (volume elements). In the case of x-ray tomography, similar to x-ray Radiography, the quantity being imaged is the distribution of the attenuation coefficient μ(x) within the object of interest. The different is only on the technique to produce the tomogram. The image of x-ray radiography can be produced straight foward after exposed to x-ray, while the image of tomography produces by combination of radiography images in every angle of projection. A number of image reconstruction methods by converting x-ray attenuation data into a tomography image have been produced by researchers. In this work, Ramp filter in "filtered back projection" has been applied. The linear data acquired at each angular orientation are convolved with a specially designed filter and then back projected across a pixel field at the same angle. This paper describe the step of using Image J software to produce image reconstruction of x-ray tomography.

  5. 64 slice-coronary computed tomography sensitivity and specificity in the evaluation of coronary artery bypass graft stenosis: A meta-analysis.

    PubMed

    Barbero, Umberto; Iannaccone, Mario; d'Ascenzo, Fabrizio; Barbero, Cristina; Mohamed, Abdirashid; Annone, Umberto; Benedetto, Sara; Celentani, Dario; Gagliardi, Marco; Moretti, Claudio; Gaita, Fiorenzo

    2016-08-01

    A non-invasive approach to define grafts patency and stenosis in the follow-up of coronary artery bypass graft (CABG) patients may be an interesting alternative to coronary angiography. 64-slice-coronary computed tomography is nowadays a diffused non-invasive method that permits an accurate evaluation of coronary stenosis, due to a high temporal and spatial resolution. However, its sensitivity and specificity in CABG evaluation has to be clearly defined, since published studies used different protocols and scanners. We collected all studies investigating patients with stable symptoms and previous CABG and reporting the comparison between diagnostic performances of invasive coronary angiography and 64-slice-coronary computed tomography. As a result, sensitivity and specificity of 64-slice-coronary computed tomography for CABG occlusion were 0.99 (95% CI 0.97-1.00) and 0.99 (95% CI: 0.99-1.00) with an area under the curve (AUC) of 0.99. 64-slice-coronary computed tomography sensitivity and specificity for the presence of any CABG stenosis >50% were 0.98 (95% CI: 0.97-0.99) and 0.98 (95% CI: 0.96-0.98), while AUC was 0.99. At meta-regression, neither the age nor the time from graft implantation had effect on sensitivity and specificity of 64-slice-coronary computed tomography detection of significant CABG stenosis or occlusion. In conclusion 64-slice-coronary computed tomography confirmed its high sensitivity and specificity in CABG stenosis or occlusion evaluation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. High-resolution corneal topography and tomography of fish eye using wide-field white light interference microscopy

    NASA Astrophysics Data System (ADS)

    Srivastava, Vishal; Nandy, Sreyankar; Singh Mehta, Dalip

    2013-04-01

    Topography and tomography of fish cornea is reconstructed using high resolution white light interference microscopy. White light interferograms at different depths were recorded by moving the object axially. For each depth position, five phase shifted interferograms were recorded and analyzed. From the reconstructed phase maps, the corneal topography and hence the refractive index was determined and from amplitude images the cross-sectional image of fish cornea was reconstructed. In the present method, we utilize a nearly common-path interference microscope and wide field illumination and hence do not require any mechanical B-scan. Therefore, the phase stability of the recorded data is improved.

  7. Registration area and accuracy when integrating laser-scanned and maxillofacial cone-beam computed tomography images.

    PubMed

    Sun, LiJun; Hwang, Hyeon-Shik; Lee, Kyung-Min

    2018-03-01

    The purpose of this study was to examine changes in registration accuracy after including occlusal surface and incisal edge areas in addition to the buccal surface when integrating laser-scanned and maxillofacial cone-beam computed tomography (CBCT) dental images. CBCT scans and maxillary dental casts were obtained from 30 patients. Three methods were used to integrate the images: R1, only the buccal and labial surfaces were used; R2, the incisal edges of the anterior teeth and the buccal and distal marginal ridges of the second molars were used; and R3, labial surfaces, including incisal edges of anterior teeth, and buccal surfaces, including buccal and distal marginal ridges of the second molars, were used. Differences between the 2 images were evaluated by color-mapping methods and average surface distances by measuring the 3-dimensional Euclidean distances between the surface points on the 2 images. The R1 method showed more discrepancies between the laser-scanned and CBCT images than did the other methods. The R2 method did not show a significant difference in registration accuracy compared with the R3 method. The results of this study indicate that accuracy when integrating laser-scanned dental images into maxillofacial CBCT images can be increased by including occlusal surface and incisal edge areas as registration areas. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  8. Experimental evaluation of fingerprint verification system based on double random phase encoding

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiroyuki; Yamaguchi, Masahiro; Yachida, Masuyoshi; Ohyama, Nagaaki; Tashima, Hideaki; Obi, Takashi

    2006-03-01

    We proposed a smart card holder authentication system that combines fingerprint verification with PIN verification by applying a double random phase encoding scheme. In this system, the probability of accurate verification of an authorized individual reduces when the fingerprint is shifted significantly. In this paper, a review of the proposed system is presented and preprocessing for improving the false rejection rate is proposed. In the proposed method, the position difference between two fingerprint images is estimated by using an optimized template for core detection. When the estimated difference exceeds the permissible level, the user inputs the fingerprint again. The effectiveness of the proposed method is confirmed by a computational experiment; its results show that the false rejection rate is improved.

  9. Smart Methods for Linezolid Determination in the Presence of Alkaline and Oxidative Degradation Products Utilizing Their Overlapped Spectral Bands

    NASA Astrophysics Data System (ADS)

    Abd El-Monem Hegazy, M.; Shaaban Eissa, M.; Abd El-Sattar, O. I.; Abd El-Kawy, M. M.

    2014-09-01

    Linezolid (LIN) is considered the first available oxazolidinone antibacterial agent. It is susceptible to hydrolysis and oxidation. Five simple, accurate, sensitive and validated UV spectrophotometric methods were developed for LIN determination in the presence of its alkaline (ALK) and oxidative (OXD) degradation products in bulk powder and pharmaceutical formulation. Method A is a second derivative one (D2) in which LIN is determined at 240.9 nm. Method B is a pH-induced differential derivative one where LIN is determined using the fourth derivative (D4) of the difference spectra (ΔA) at 285.3 nm. Methods C, D, and E are manipulating ratio spectra, where C is the double divisor-ratio difference spectrophotometric one (DD-RD) in which LIN was determined by calculating the amplitude difference at 243.7 and 267.6 nm of the ratio spectra. Method D is the double divisor-first derivative of ratio spectra (DD-DD1) in which LIN was determined at 270.2 nm. Method E is a mean centering of ratio spectra one (MCR) in which LIN was determined at 318.0 nm. The developed methods have been validated according to ICH guidelines. The results were statistically compared to that of a reported HPLC method and there was no significant difference regarding both accuracy and precision.

  10. Simulating the influence of scatter and beam hardening in dimensional computed tomography

    NASA Astrophysics Data System (ADS)

    Lifton, J. J.; Carmignato, S.

    2017-10-01

    Cone-beam x-ray computed tomography (XCT) is a radiographic scanning technique that allows the non-destructive dimensional measurement of an object’s internal and external features. XCT measurements are influenced by a number of different factors that are poorly understood. This work investigates how non-linear x-ray attenuation caused by beam hardening and scatter influences XCT-based dimensional measurements through the use of simulated data. For the measurement task considered, both scatter and beam hardening are found to influence dimensional measurements when evaluated using the ISO50 surface determination method. On the other hand, only beam hardening is found to influence dimensional measurements when evaluated using an advanced surface determination method. Based on the results presented, recommendations on the use of beam hardening and scatter correction for dimensional XCT are given.

  11. Statistical reconstruction for cosmic ray muon tomography.

    PubMed

    Schultz, Larry J; Blanpied, Gary S; Borozdin, Konstantin N; Fraser, Andrew M; Hengartner, Nicolas W; Klimenko, Alexei V; Morris, Christopher L; Orum, Chris; Sossong, Michael J

    2007-08-01

    Highly penetrating cosmic ray muons constantly shower the earth at a rate of about 1 muon per cm2 per minute. We have developed a technique which exploits the multiple Coulomb scattering of these particles to perform nondestructive inspection without the use of artificial radiation. In prior work [1]-[3], we have described heuristic methods for processing muon data to create reconstructed images. In this paper, we present a maximum likelihood/expectation maximization tomographic reconstruction algorithm designed for the technique. This algorithm borrows much from techniques used in medical imaging, particularly emission tomography, but the statistics of muon scattering dictates differences. We describe the statistical model for multiple scattering, derive the reconstruction algorithm, and present simulated examples. We also propose methods to improve the robustness of the algorithm to experimental errors and events departing from the statistical model.

  12. Cryo-tomography Tilt-series Alignment with Consideration of the Beam-induced Sample Motion

    PubMed Central

    Fernandez, Jose-Jesus; Li, Sam; Bharat, Tanmay A. M.; Agard, David A.

    2018-01-01

    Recent evidence suggests that the beam-induced motion of the sample during tilt-series acquisition is a major resolution-limiting factor in electron cryo-tomography (cryoET). It causes suboptimal tilt-series alignment and thus deterioration of the reconstruction quality. Here we present a novel approach to tilt-series alignment and tomographic reconstruction that considers the beam-induced sample motion through the tilt-series. It extends the standard fiducial-based alignment approach in cryoET by introducing quadratic polynomials to model the sample motion. The model can be used during reconstruction to yield a motion-compensated tomogram. We evaluated our method on various datasets with different sample sizes. The results demonstrate that our method could be a useful tool to improve the quality of tomograms and the resolution in cryoET. PMID:29410148

  13. Optical Microangiography Based on Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Reif, Roberto; Wang, Ruikang K.

    Proper homeostasis regulation of in vivo biological systems requires microvascular blood perfusion, which is the process of delivering blood into the tissue's capillary beds. Abnormal tissue vascularization has been associated with various diseases such as cancer, diabetes, neurological disorders, wounds, and inflammation. Understanding the changes in the vascular network or microangiography will have an important role in determining the causes and developing potential treatments for these diseases. Optical coherence tomography (OCT) is a noninvasive method for imaging three-dimensional biological tissues with high resolution (~10 µm) and without requiring the use of contrast agents. In this chapter we review several techniques for using OCT to determine blood flow velocities and the vessel morphology (optical microangiography). Different techniques will be discussed with a brief explanation of their limitations. Also, methods for quantifying these images are presented, as well as the depiction of several applications.

  14. Monitoring and Characterizing Crop Root Systems Using Electrical Impedance Tomography (EIT)

    NASA Astrophysics Data System (ADS)

    Weigand, M.; Kemna, A.

    2016-12-01

    A better understanding of root-soil interactions and associated processes is essential to achieve progress in crop breeding and management, prompting the need for high-resolution and non-destructive characterization methods. Such methods are still lacking, in particular for characterizing root growth and function in the field. A promising technique in this respect is electrical impedance tomography (EIT), which provides images of the low-frequency electrical conduction and polarization properties and thus can be used to investigate polarization processes occurring within and in the direct vicinity of roots under the influence of an external alternating electric field. This approach takes advantage of the well-known polarization properties associated with electrical double layers forming at membranes of cells and cell clusters. However, upscaling these processes to the scale of an impedance, or complex conductivity, spectrum of the whole root system is not trivial given the lack of electrical root models, the complexity of root systems, and the occurrence of additional larger-scale, ion-selective, and therefore polarizable, structures such as the Casparian strip. We here present results from several EIT laboratory studies on rhizotrons with crop root systems in aqueous solutions. Based on optimized experimental and data analysis procedures, enabling the imaging of the weak signals encountered in our studies, we found systematic spatial and temporal changes of both the magnitude and the shape of the spectral polarization signatures during nutrient deprivation and in response to the decapitation of plants. Consistent, but relatively weak, spectral impedance changes were also observed over diurnal cycles. Our results provide evidence for the capability of EIT to non-invasively image and monitor root systems at the rhizotron scale. They further suggest that EIT is a promising tool for imaging, characterizing, and monitoring crop roots at the field scale.

  15. Master-slave interferometry for parallel spectral domain interferometry sensing and versatile 3D optical coherence tomography.

    PubMed

    Podoleanu, Adrian Gh; Bradu, Adrian

    2013-08-12

    Conventional spectral domain interferometry (SDI) methods suffer from the need of data linearization. When applied to optical coherence tomography (OCT), conventional SDI methods are limited in their 3D capability, as they cannot deliver direct en-face cuts. Here we introduce a novel SDI method, which eliminates these disadvantages. We denote this method as Master - Slave Interferometry (MSI), because a signal is acquired by a slave interferometer for an optical path difference (OPD) value determined by a master interferometer. The MSI method radically changes the main building block of an SDI sensor and of a spectral domain OCT set-up. The serially provided signal in conventional technology is replaced by multiple signals, a signal for each OPD point in the object investigated. This opens novel avenues in parallel sensing and in parallelization of signal processing in 3D-OCT, with applications in high- resolution medical imaging and microscopy investigation of biosamples. Eliminating the need of linearization leads to lower cost OCT systems and opens potential avenues in increasing the speed of production of en-face OCT images in comparison with conventional SDI.

  16. An Effective Measured Data Preprocessing Method in Electrical Impedance Tomography

    PubMed Central

    Yu, Chenglong; Yue, Shihong; Wang, Jianpei; Wang, Huaxiang

    2014-01-01

    As an advanced process detection technology, electrical impedance tomography (EIT) has widely been paid attention to and studied in the industrial fields. But the EIT techniques are greatly limited to the low spatial resolutions. This problem may result from the incorrect preprocessing of measuring data and lack of general criterion to evaluate different preprocessing processes. In this paper, an EIT data preprocessing method is proposed by all rooting measured data and evaluated by two constructed indexes based on all rooted EIT measured data. By finding the optimums of the two indexes, the proposed method can be applied to improve the EIT imaging spatial resolutions. In terms of a theoretical model, the optimal rooting times of the two indexes range in [0.23, 0.33] and in [0.22, 0.35], respectively. Moreover, these factors that affect the correctness of the proposed method are generally analyzed. The measuring data preprocessing is necessary and helpful for any imaging process. Thus, the proposed method can be generally and widely used in any imaging process. Experimental results validate the two proposed indexes. PMID:25165735

  17. Reduction of variable-truncation artifacts from beam occlusion during in situ x-ray tomography

    NASA Astrophysics Data System (ADS)

    Borg, Leise; Jørgensen, Jakob S.; Frikel, Jürgen; Sporring, Jon

    2017-12-01

    Many in situ x-ray tomography studies require experimental rigs which may partially occlude the beam and cause parts of the projection data to be missing. In a study of fluid flow in porous chalk using a percolation cell with four metal bars drastic streak artifacts arise in the filtered backprojection (FBP) reconstruction at certain orientations. Projections with non-trivial variable truncation caused by the metal bars are the source of these variable-truncation artifacts. To understand the artifacts a mathematical model of variable-truncation data as a function of metal bar radius and distance to sample is derived and verified numerically and with experimental data. The model accurately describes the arising variable-truncation artifacts across simulated variations of the experimental setup. Three variable-truncation artifact-reduction methods are proposed, all aimed at addressing sinogram discontinuities that are shown to be the source of the streaks. The ‘reduction to limited angle’ (RLA) method simply keeps only non-truncated projections; the ‘detector-directed smoothing’ (DDS) method smooths the discontinuities; while the ‘reflexive boundary condition’ (RBC) method enforces a zero derivative at the discontinuities. Experimental results using both simulated and real data show that the proposed methods effectively reduce variable-truncation artifacts. The RBC method is found to provide the best artifact reduction and preservation of image features using both visual and quantitative assessment. The analysis and artifact-reduction methods are designed in context of FBP reconstruction motivated by computational efficiency practical for large, real synchrotron data. While a specific variable-truncation case is considered, the proposed methods can be applied to general data cut-offs arising in different in situ x-ray tomography experiments.

  18. New Prospecting Standarts and Its Comparison with International Regulations in Sinkhole and Cave Investigations

    NASA Astrophysics Data System (ADS)

    Karabulut, S.; Cengiz Cinku, M.; Tezel, O.

    2016-12-01

    The aim of this study is to investigate the prospecting standarts in sinkhole and cave characterization comparing it with the present standarts given by the American Society for Testing and Materials (ASTM) and the British Standart (BSI). Cave and sinkholes which are important geological occurences could cause hazard and collapse of the ground where residental areas could be under risk. The depth of sinkholes could reach up to hundreds of meters and their width to tens of meters. Most caves which are under conserve and characterized as a natural protected area, a non-destructive investigation is required which is only undertaken by geophysical applications. Two different type of standarts are given in the literature to investigate this kind of geological occurences. The first is the ASTM (1999) standart which offers to use Gravity/Microgravity, Ground Penetrating Radar (GPR) and Electromagnetic, while the BSI standart (1999) depends on the initial application of GPR, Electromagnetic, Electrical Resistivity and Crosshole Seismic. In Turkey however, there are limited studies in cave/sinkhole detection and no standartization in prospecting is presented. For this purpose, we applied a geophysical study in the Yarımburgaz cave, Istanbul/Turkey. In the scope of this study, Microgravity, Electric Tomography, Tomography of Seismic Refraction and Surface Wave Analysis, GPR and Microtremor methods are applied on four different profiles. It has been shown that the outputs of the methods differ as a result of the climatic conditions, properties of the geological environment and the depth/size/shape of the sinkhole/cave. Besides this, the area of application which is either inside the city center, steep valley or on the sea/streamside show also discrepancy in the order of preference of the geophysical application methods when considering the anomalies on different mediums. The results obtained from GPR are deep in relation with the thickness of the clayey unit, the water content of the medium and the thickness of the cave/sinkhole. Microgravity, GPR and Microtremor measurements were applied successfull and easily in the inner-city, while Electric Tomography, Seismic Refraction and MASW Methods showed reliable results which are obtained rapidly.

  19. Intra-tumour 18F-FDG uptake heterogeneity decreases the reliability on target volume definition with positron emission tomography/computed tomography imaging.

    PubMed

    Dong, Xinzhe; Wu, Peipei; Sun, Xiaorong; Li, Wenwu; Wan, Honglin; Yu, Jinming; Xing, Ligang

    2015-06-01

    This study aims to explore whether the intra-tumour (18) F-fluorodeoxyglucose (FDG) uptake heterogeneity affects the reliability of target volume definition with FDG positron emission tomography/computed tomography (PET/CT) imaging for nonsmall cell lung cancer (NSCLC) and squamous cell oesophageal cancer (SCEC). Patients with NSCLC (n = 50) or SCEC (n = 50) who received (18)F-FDG PET/CT scanning before treatments were included in this retrospective study. Intra-tumour FDG uptake heterogeneity was assessed by visual scoring, the coefficient of variation (COV) of the standardised uptake value (SUV) and the image texture feature (entropy). Tumour volumes (gross tumour volume (GTV)) were delineated on the CT images (GTV(CT)), the fused PET/CT images (GTV(PET-CT)) and the PET images, using a threshold at 40% SUV(max) (GTV(PET40%)) or the SUV cut-off value of 2.5 (GTV(PET2.5)). The correlation between the FDG uptake heterogeneity parameters and the differences in tumour volumes among GTV(CT), GTV(PET-CT), GTV(PET40%) and GTV(PET2.5) was analysed. For both NSCLC and SCEC, obvious correlations were found between uptake heterogeneity, SUV or tumour volumes. Three types of heterogeneity parameters were consistent and closely related to each other. Substantial differences between the four methods of GTV definition were found. The differences between the GTV correlated significantly with PET heterogeneity defined with the visual score, the COV or the textural feature-entropy for NSCLC and SCEC. In tumours with a high FDG uptake heterogeneity, a larger GTV delineation difference was found. Advance image segmentation algorithms dealing with tracer uptake heterogeneity should be incorporated into the treatment planning system. © 2015 The Royal Australian and New Zealand College of Radiologists.

  20. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

    PubMed Central

    Shokri, Abbas; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-01-01

    Purpose This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. Results In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes (P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results. PMID:29581947

Top